Sample records for high-activity icp-aes measurements

  1. Obsidian provenance studies in archaeology: A comparison between PIXE, ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Bellot-Gurlet, Ludovic; Poupeau, Gerard; Salomon, Joseph; Calligaro, Thomas; Moignard, Brice; Dran, Jean-Claude; Barrat, Jean-Alix; Pichon, Laurent

    2005-01-01

    Elemental composition fingerprinting by PIXE technique is very attractive for obsidian provenance studies as it may proceed in a non-destructive mode, even if a more complete elemental characterization can be obtained by ICP-MS and/or ICP-AES. Only few studies have compared results obtained by both methods for solid rock samples. In this work, elemental compositions were determined by ICP-MS/-AES for international geochemical standards and by ICP-MS/-AES and PIXE for inter-laboratory reference obsidians. In addition 49 obsidian source samples and artefacts were analysed by both ICP-MS/-AES and PIXE. Instrumental work and measurement quality control performed for obsidian chemical characterization, underline that PIXE and ICP-MS/-AES provide reproducible, accurate and comparable measurements. In some volcanic districts the limited number of elements dosed by PIXE is sufficient for the discrimination of the potential raw sources of obsidians. Therefore, PIXE can be an advantageous substitute to ICP-MS/-AES techniques for provenance studies

  2. Some aspects of ICP-AES analysis of high purity rare earths

    International Nuclear Information System (INIS)

    Murty, P.S.; Biswas, S.S.

    1991-01-01

    Inductively coupled plasma atomic emission spectrometry (ICP-AES) is a technique capable of giving high sensitivity in trace elemental analysis. While the technique possesses high sensitivity, it lacks high selectivity. Selectivity is important where substances emitting complex spectra are to be analysed for trace elements. Rare earths emit highly complex spectra in a plasma source and the determination of adjacent rare earths in a high purity rare earth matrix, with high sensitivity, is not possible due to the inadequate selectivity of ICP-AES. One approach that has yielded reasonably good spectral selectivity in the high purity rare earth analysis by ICP-AES is by employing a combination of wavelength modulation techniques and high resolution echelle grating. However, it was found that by using a high resolution monochromator senstitivities either comparable to or better than those reported by the wavelength modulation technique could be obtained. (author). 2 refs., 2 figs., 2 tabs

  3. Toepassing ICP-AES op het RIKILT

    NARCIS (Netherlands)

    Ruig, de W.G.

    1980-01-01

    Rapportage over de toepassing van ICP-AES op het RIKILT. Bij ICP-AES worden twee manieren van lichtemissie detectie toegepast nl. simultaan en sequentieel. De voor- en nadelen van ICP-AES t.o.v. AAS worden op een rij gezet.

  4. ICP-AES determination of trace elements in carbon steel

    International Nuclear Information System (INIS)

    Sengupta, Arijit; Rajeswari, B.; Kadam, R.M.; Babu, Y.; Godbole, S.V.

    2010-01-01

    Full text: Carbon steel, a combination of the elements iron and carbon, can be classified into four types as mild, medium, high and very high depending on the carbon content which varies from 0.05% to 2.1%. Carbon steel of different types finds application in medical devices, razor blades, cutlery and spring. In the nuclear industry, it is used in feeder pipes in the reactor. A strict quality control measure is required to monitor the trace elements, which have deleterious effects on the mechanical properties of the carbon steel. Thus, it becomes imperative to check the purity of carbon steel as a quality control measure before it is used in feeder pipes in the reactor. Several methods have been reported in literature for trace elemental determination in high purity iron. Some of these include neutron activation analysis, atomic absorption spectrometry and atomic emission spectrometry. Inductively coupled plasma atomic emission spectrometry (ICP-AES) is widely recognized as a sensitive technique for the determination of trace elements in various matrices, its major advantages being good accuracy and precision, high sensitivity, multi-element capability, large linear dynamic range and relative freedom from matrix effects. The present study mainly deals with the direct determination of trace elements in carbon steel using ICP-AES. An axially viewing ICP spectrometer having a polychromator with 35 fixed analytical channels and limited sequential facility to select any analytical line within 2.2 nm of a polychromator line was used in these studies. Iron, which forms one of the main constituents of carbon steel, has a multi electronic configuration with line rich emission spectrum and, therefore, tends to interfere in the determination of trace impurities in carbon steel matrix. Spectral interference in ICP-AES can be seriously detrimental to the accuracy and reliability of trace element determinations, particularly when they are performed in the presence of high

  5. Multielemental analysis of Korean geological reference samples by INAA, ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Naoki Shirai; Hiroki Takahashi; Yuta Yokozuka; Mitsuru Ebihara; Meiramkhan Toktaganov; Shun Sekimoto

    2015-01-01

    Six Korean geological reference samples (KB-1, KGB-1, KT-1, KD-1, KG-1 and KG-2) prepared by Korea Institutes of Geoscience and Mineral Resources were analyzed by using INAA, ICP-AES and ICP-MS. Some elements could be determined by both INAA and non-INAA methods (ICP-AES and ICP-MS), and these data are consistent with each other. This study confirms that a combination of ICP-AES and ICP-MS is comparable to INAA in determining a wide range of major, minor and trace elements in geological materials. (author)

  6. Development of ICP-AES based method for the characterization of high level waste

    International Nuclear Information System (INIS)

    Seshagiri, T.K.; Thulsidas, S.K.; Adya, V.C.; Kumar, Mithlesh; Radhakrishnan, K.; Mary, G.; Kulkarni, P.G.; Bhalerao, Bharti; Pant, D.K.

    2011-01-01

    An Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) method was developed for the trace metal characterization of high level waste solutions (HLW) of different origin and the method was validated by analysis of synthetic samples of simulated high level waste solutions (SHLW) from spent fuels of varying composition. In this context, an inter-laboratory comparison exercise (ILCE) was carried out with the simulated HLW of different spent fuel types, viz., research reactor (RR), pressurized heavy water reactor (PHWR) and fast breeder reactor (FBR). An over view of the ICP-AES determination of trace metallic constituents in such SHLW solutions is presented. The overall agreement between the various laboratories was good. (author)

  7. Transition metal analysis. A comparison between ICP-AES and deuteron activation

    International Nuclear Information System (INIS)

    Pillay, A.E.; Williams, J.R.; Hassan, S.M.; Al-Hamdi, A.; El Mardi, M.O.

    2002-01-01

    The analytical capabilities of ICP-AES (ICP) and deuteron activation (associated with prompt gamma-rays and delayed X-rays) for the determination of certain transition metals, were investigated. The sensitivities of the three methods are given, and the general applicability of each technique is evaluated. In the case of ICP, numerical data were obtained from aqueous solutions containing digested plant material. These experimental results were assessed against minimum detectable limits attained in relevant solid matrices that were subjected to prompt gamma-ray and delayed X-ray spectrometry using 5 MeV 2 H + ions. The analytically useful lines originated mainly from (d,p) and (d,n) reactions. The potential of the three techniques for routine analysis is discussed and detailed methodologies are presented. (author)

  8. Environmental application of XRF, ICP-AES and INAA on biological matrix

    International Nuclear Information System (INIS)

    Zararsiz, A.; Dogangun, A.; Tuncel, S.

    2004-01-01

    Full text: It is very important to determine trace quantities of metals in different matrices with high accuracy since the metals are used as markers for different sources in air pollution studies. In this study, the analytical capabilities of XRF, ICP-AES and INM techniques on a biological matrix namely lichens, which are widely used as bio monitoring organisms for the pollutants mapping in the atmosphere, were tested. Lichen samples were collected in Aegean Region of Turkey where pollution is an important issue. 9 elements were determined by XRF, 14 elements by ICP-AES and 13 elements by INM. Quality assurance was achieved using lichen SRM (IAEA-336) and Orchard leaves SRM (NIST- 1571). Produced data are subjected to statistical tests, like t-test, Q-test in order to determine the accuracy and precision of each technique. A recommendation list of the proper analytical technique is obtained for determination of each specific element considering analytical capabilities of ICP-AES, XRF and INM. As a result we can recommend that the first choice for Cd, Cu, Mg is ICP-AES, for In, K, Rb is INAA, for Br is XRF, if the concentrations are not close to the detection limit of XRF. For V, Cr, AI, Na, Fe ICP-AES and INM are both well, for Pb ICP-AES and XRF are both well, if the concentrations are not close to the detection limit of XRF, for Mn and Ca INM, XRF and ICP-AES are all give similar results for this type of biological matrix

  9. High-Activity ICP-AES Measurements in the ATALANTE Facility Applied to Analytical Monitoring of an Extraction Test

    International Nuclear Information System (INIS)

    Esbelin, E.; Boyer-Deslys, V.; Beres, A.; Viallesoubranne, C.

    2008-01-01

    The Material Analysis and Metrology Laboratory (LAMM) of the Cea's Atalante complex ensures analytical monitoring of enhanced separation tests. Certain fission products, actinides and lanthanides were assayed by ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectroscopy) in the CBA shielded analysis line. These analyses were particularly effective for controlling the Diamex test, and contributed to its success. The Diamex process consists in extracting the actinides and lanthanides from a Purex raffinate using a diamide, DMDOHEMA, followed by stripping at low acidity. The major elements analyzed during the test were Am, Nd, Mo, Fe, and Zr

  10. High-Activity ICP-AES Measurements in the ATALANTE Facility Applied to Analytical Monitoring of an Extraction Test

    Energy Technology Data Exchange (ETDEWEB)

    Esbelin, E.; Boyer-Deslys, V.; Beres, A.; Viallesoubranne, C. [CEA Marcoule, DEN/DRCP/SE2A/LAMM, BP17171, 30207 Bagnols-sur-Ceze (France)

    2008-07-01

    The Material Analysis and Metrology Laboratory (LAMM) of the Cea's Atalante complex ensures analytical monitoring of enhanced separation tests. Certain fission products, actinides and lanthanides were assayed by ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectroscopy) in the CBA shielded analysis line. These analyses were particularly effective for controlling the Diamex test, and contributed to its success. The Diamex process consists in extracting the actinides and lanthanides from a Purex raffinate using a diamide, DMDOHEMA, followed by stripping at low acidity. The major elements analyzed during the test were Am, Nd, Mo, Fe, and Zr.

  11. Forensic discrimination of aluminum foil by SR-XRF and ICP-AES

    International Nuclear Information System (INIS)

    Kasamatsu, Masaaki; Suzuki, Yasuhiro; Suzuki, Shinichi; Miyamoto, Naoki; Watanabe, Seiya; Shimoda, Osamu; Takatsu, Masahisa; Nakanishi, Toshio

    2010-01-01

    The application of synchrotron radiation X-ray fluorescence spectrometry (SR-XRF) was investigated for the forensic discrimination of aluminum foil by comparisons of the elemental components. Small fragments (1 x 1 mm) were taken from 4 kinds of aluminum foils produced by different manufactures and used for measurements of the XRF spectrum at BL37XU of SPring-8. A comparison of the XRF spectra was effective for the discrimination of aluminum foils from different sources, because significant differences were observed in the X-ray peak intensities of Fe, Cu, Zn, Ga, Zr and Sn. These elements, except for Zr and Sn in the aluminum foils and NIST SRM1258 (Aluminium Alloy 6011), were also determined by inductively coupled plasma atomic emission spectrometry (ICP-AES). The observed values of Fe, Cu, Zn and Ga in NIST standard samples by ICP-AES showed satisfactorily good agreements with the certified or information values with relative standard deviations from 1.1% for Zn to 6.7% for Ga. The observed values for the aluminum foils by ICP-AES were compared with those by SR-XRF. Correlation coefficients from 0.997 for Cu/Fe to 0.999 for Zn/Fe and Ga/Fe were obtained between the ratio of the elemental concentration by ICP-AES and normalized the X-ray intensity by SR-XRF. This result demonstrates that a comparison of the normalized X-ray intensity is nearly as effective for the discrimination of aluminum foils as quantitative analysis by ICP-AES. Comparisons of the analytical results by SR-XRF allow the discrimination of all aluminum foils using only a 1 mm 2 fragment with no destruction of the samples. (author)

  12. Comparison of elemental quantity by PIXE and ICP-MS and/or ICP-AES for NIST standards

    International Nuclear Information System (INIS)

    Saitoh, K.; Sera, K.; Gotoh, T.; Nakamura, M.

    2002-01-01

    Urban particulate matter (SRM 1648), Buffalo River sediment (SRM 2704) and pine needle (SRM 1575) standard reference materials prepared by the National Institute of Standards and Technology (NIST, USA) were analyzed by three multi-element analysis methods, i.e., particle induced X-ray emission (PIXE), inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES); values determined by those analysis methods were compared with certified and/or non-certified values of NIST samples. Values determined by PIXE were 70-120% relative to certified and/or non-certified values of NIST samples except for Co in the urban particulate matter, for V and Co in Buffalo River sediment and for Ni and Br in the pine needles samples. In particular, Al, K, Ca, Cr, Mn, Fe, Cu, Zn and Pb were 85-110% in all samples. On the other hand, Na and Fe values determined by ICP-MS were very much different from the certified values in all samples, but the other elements were 70-120%. As for ICP-AES, all elements except for Na were 80-100% in all samples. Comparing the values determined by PIXE and those determined by ICP-MS and/or ICP-AES, there was a slight difference between the samples, but the range was 75-120% except for Na, V, Fe and Co determined by ICP-MS and Na determined by ICP-AES, which was generally consistent with PIXE

  13. A determination method of Ru, Rh and Pd in high-level liquid waste (HLLW) by cation exchange separation and ICP-AES measurement

    International Nuclear Information System (INIS)

    Cao Desheng; Duan Shirong; Qin Fengzhou; Li Jinying; Zhang Huaili

    1992-01-01

    The authors describe a determination method of Ru, Rh and Pd in HLLW with cation-exchange separation and ICP-AES measurement. A sample of HLLW was treated with the hydrochloride acid containing enough sodium chloride, then passed through a strongly acidic cation-exchange resin column, the Ru, Rh and Pd as chloro-complexes go to the eluate while the interference elements are absorbed on the resins in the column. The Ru, Rh and Pd are collected and determined by ICP-AES. The obtained results show that the recovery is 90% and the relative standard deviation is 6% as the Ru content within the range (35-230) x 10 -6 ; the recovery is 106% and RSD is 10% as the Rh content within (2-20) x 10 -6 ; and the recovery of Pd is 72% as its content less than 2 x 10 -6

  14. A comparison between PIXE and ICP-AES measurements of metals in aerosol particulate collected in urban and marine sites in Italy

    Energy Technology Data Exchange (ETDEWEB)

    Traversi, R.; Becagli, S. [Department of Chemistry “Ugo Schiff”, University of Florence, Via della Lastruccia 3, I-50019 Sesto F.no, Florence (Italy); Calzolai, G.; Chiari, M.; Giannoni, M. [Department of Physics and Astronomy, University of Florence and I.N.F.N., Florence, Via G. Sansone 1, I-50019 Sesto F.no, Florence (Italy); Lucarelli, F., E-mail: lucarelli@fi.infn.it [Department of Physics and Astronomy, University of Florence and I.N.F.N., Florence, Via G. Sansone 1, I-50019 Sesto F.no, Florence (Italy); Nava, S. [Department of Physics and Astronomy, University of Florence and I.N.F.N., Florence, Via G. Sansone 1, I-50019 Sesto F.no, Florence (Italy); Rugi, F.; Severi, M.; Udisti, R. [Department of Chemistry “Ugo Schiff”, University of Florence, Via della Lastruccia 3, I-50019 Sesto F.no, Florence (Italy)

    2014-01-01

    PIXE and ICP-AES techniques are largely used in atmospheric aerosol studies. Since PIXE is able to provide the total elemental concentrations, while ICP-AES results depend on the extraction conditions, parallel PIXE and ICP-AES measurements of Fe, Al, Cu, Pb, Mn, Cr, Ni, V, As on PM10 and PM2.5 samples were compared. Two extraction procedures were applied to samples from 5 sites at different anthropization level in Italy: a “weak” extraction (HNO{sub 3} at pH = 1.5) and a “strong” extraction (micro-wave oven in HNO{sub 3} and H{sub 2}O{sub 2} – following EU rules). The amount of the metal extracted in the different conditions resulted to be strongly dependent on the sampling site, on the main sources of the particle (crustal or anthropic) containing the metal and on the sampled size class.

  15. Multielement determination of major-to-ultratrace elements in deep-seawater salts by ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Sakai, Takeshi; Nakagawa, Koji; Nakajima, Hiroshi; Itoh, Akihide; Ji, Shan; Haraguchi, Hiroki

    2002-01-01

    Major-to-ultratrace elements in deep-seawater salts were determined by ICP-AES and ICP-MS, after they were separated into the water-soluble, acid-soluble, and insoluble particle components. Deep-seawater salts were prepared from seawater collected at 344 m deep near the off-shore of Cape Muroto in Kochi Prefecture. The major and minor elements in salts were determined by ICP-AES after appropriate dilution with pure water. Trace and ultratrace elements in the water-soluble and acid-soluble components were preconcentrated by a chelating resin preconcentration method. In addition, the major to-ultratrace elements in the insoluble particle component were determined by ICP-AES and ICP-MS, after acid-digestion using HNO 3 /HF/HClO 4 . As a result, 21-35 elements in deep-seawater salts could be determined over the wide concentration range. It was found that the elements, such as Al, V, Fe, Mn, Co, Cu, Zn, and rare earth elements, were more abundant in the acid-soluble component of deep-seawater salts, which may play some essential roles in physiological effectiveness for intake of salt. (author)

  16. Estimation of metal ions during the dissolution of corrosion product oxides by ICP-AES

    International Nuclear Information System (INIS)

    Sathyaseelan, V.S.; Mittal, Vinit Kumar; Velmurugan, S.

    2012-01-01

    Inductively coupled plasma atomic emission spectroscopy (ICP-AES) is one of the several techniques, which is being widely used for both qualitative and quantitative estimation of various elements. Determination of metals in wine, arsenic in food, trace elements in soil, nutrient levels in agricultural soils, trace elements bound to protein, motor oil analysis etc. are the examples of its application. ICP-AES utilizes plasma as the atomization and excitation source. The plasma temperature in the analytical zone ranges from 5000-8000 K. This high temperature assures that most of the compounds in the samples are completely atomized. Advantages of ICP-AES are high sensitivity and linear dynamic range, multi-element capability, low chemical interference and a stable and reproducible signal. The typical limits of detection for some of the elements like Mg, Sr, Ca, Li, Cu etc are well below 1 μg L -1

  17. Nutritional and environmental properties of algal products used in healthy diet by INAA and ICP-AES

    International Nuclear Information System (INIS)

    Avino, P.; Lepore, L.; Carconi, P.L.; Moauro, A.

    2000-01-01

    Spirulina platensis alga sampled in the Caribbean Sea and seven other commercial algal products available on the Italian market of different origin and aspect, have been analyzed by instrumental neutron activation analysis (INAA) and inductively coupled plasma-atomic emission spectrometry (ICP-AES). By neutron irradiation and γ-ray spectrometry (INAA), as many as 20 elements could be measured instrumentally without any chemical treatment. Cu, Mg, Mn and Pb were determined after dissolution of the sample by ICP-AES. The cross-checking of the data, specifically by comparing those of Ca, Cr, Fe and Zn, obtained by the two techniques was found to be in good agreement. Special attention from analytical and nutritional point of view has been devoted to the toxic metals. The measurements have been carried out employing the reference algal material prepared by International Atomic Energy Agency (IAEA). (author)

  18. Multielement determination and speciation of major-to-ultratrace elements in green tea leaves by ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Matsuura, Hirotaka; Hokura, Akiko; Haraguchi, Hiroki

    2000-01-01

    In order to investigate the multi-elemental composition of green tea leaves as well as chemical species in tea infusions, inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS) were used for elemental analysis and elemental speciation with the aid of size exclusion chromatography (SEC). As a result, the multielement determination of major-to-ultratrace elements in green tea leaves and green tea infusions was carried out by ICP-AES and ICP-MS. About 40 elements in these tea samples could be determined in a wide concentration range of over 8 orders of magnitude. The extraction efficiency of each element was estimated as the ratio of its concentration in tea infusion to that in tea leaves. It was found from the experimental results that the elements in tea leaves could be classified into three characteristic groups, depending on their extraction efficiencies. Furthermore, tea infusions were analyzed by a combined system of SEC, UV absorption detector, and ICP-AES (or ICP-MS) for the speciation of major-to-ultratrace elements. Most of the elements in tea infusions were found to be present as associated complexes with large organic molecules. (author)

  19. PIXE analysis of human stones: comparison with data from ICP-AES

    International Nuclear Information System (INIS)

    Pougnet, M.A.B.; Peisach, M.; Pineda, C.A.; Rodgers, A.L.

    1987-01-01

    25 human stone samples previously analyzed by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and the IAEA Animal Bone Standard Reference Material were used to evaluate trace element analysis by PIXE. Bombardment with 4 MeV protons was used for the determination of Mn, Fe, Cu, Pb, Br, Rb, Sr and Ca. PIXE and ICP-AES data gave correlation factors better than 0.97 for the elements Ca, Fe, Zn, Sr and Pb. (author) 9 refs.; 5 figs

  20. Separation techniques for the clean-up of radioactive mixed waste for ICP-AES/ICP-MS analysis

    International Nuclear Information System (INIS)

    Swafford, A.M.; Keller, J.M.

    1993-01-01

    Two separation techniques were investigated for the clean-up of typical radioactive mixed waste samples requiring elemental analysis by Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) or Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). These measurements frequently involve regulatory or compliance criteria which include the determination of elements on the EPA Target Analyte List (TAL). These samples usually consist of both an aqueous phase and a solid phase which is mostly an inorganic sludge. Frequently, samples taken from the waste tanks contain high levels of uranium and thorium which can cause spectral interferences in ICP-AES or ICP-MS analysis. The removal of these interferences is necessary to determine the presence of the EPA TAL elements in the sample. Two clean-up methods were studied on simulated aqueous waste samples containing the EPA TAL elements. The first method studied was a classical procedure based upon liquid-liquid extraction using tri-n- octylphosphine oxide (TOPO) dissolved in cyclohexane. The second method investigated was based on more recently developed techniques using extraction chromatography; specifically the use of a commercially available Eichrom TRU·Spec trademark column. Literature on these two methods indicates the efficient removal of uranium and thorium from properly prepared samples and provides considerable qualitative information on the extraction behavior of many other elements. However, there is a lack of quantitative data on the extraction behavior of elements on the EPA Target Analyte List. Experimental studies on these two methods consisted of determining whether any of the analytes were extracted by these methods and the recoveries obtained. Both methods produced similar results; the EPA target analytes were only slightly or not extracted. Advantages and disadvantages of each method were evaluated and found to be comparable

  1. PIXE and ICP-AES comparison in evaluating the efficiency of metal extraction and analysis in aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Rugi, F.; Becagli, S.; Ghedini, C.; Marconi, M.; Severi, M.; Traversi, R.; Udisti, R. [Dep. of Chemistry, University of Florence, Sesto F.no (Fl) (Italy); Calzolai, G.; Chiari, M.; Lucarelli, F.; Nava, S. [Dep. of Physics and Astronomy , University of Florence and INFN, Sesto F. no (Fl) (Italy)

    2013-07-01

    Full text: A recent EU regulation (EN 149022005) requests the quantification of selected metals in the atmospheric particulate by mineralization with H{sub 2}0{sub 2} and HN0{sub 3} in microwave oven.This method might possibly conflict with the determination of the total metal content. In fact, the more the aerosol is enriched in crustal elements the more the difference in the two methods are expected, since the H{sub 2}0{sub 2}+ HN0{sub 3}, extraction is not reliable for metals in silicate form. In order to evaluate the extracted fraction, PIXE and ICP-AES measurements were carried out on the two halves of a series of PM10 and PM2.5 samples collected on Teflon filters in an urban site in the surrounding of Florence (Italy). An ICP-AES (Inductively Coupled Plasma -Atomic Emission Spectroscopy) method was optimized by an ultrasound nebuliser (CETAC 5000 AT+), in order to improve reproducibility and detection limit. In these conditions, it was possible quantifying AI, As, Cr, Cu, Fe, Mn, Ni, Pb and Vatsub-ppb levels. PIXE analysis using the external beam set-up at LABEC and a 3 MeV proton beam was carried out in order to measure the total elemental content of the metals. By comparing the ICP-AES and the PIXE results, a preliminary evaluation of the efficiency of the H{sub 2}0{sub 2} and HN0{sub 3} extraction method was performed. The obtained results (the mean values for the ICP-AES/PIXE ratio are reported in Table 1) show that the extraction procedure following the EN 14902 directive allows quantitative recoveries (80-120%, including the analytical uncertainties)for the majority of the analysed metals, especially for those mainly emitted by anthropic sources. This result points out that anthropic metals are present in the atmosphere as relatively available species (free metals, labile complexes, carbonates, oxides). On the contrary, lower recoveries were obtained for AI (mean value around 75%), a metal that has a relevant crustal fraction. Percentage of recovery of

  2. Uncertainty assessing of measure result of tungsten in U3O8 by ICP-AES

    International Nuclear Information System (INIS)

    Du Guirong; Nie Jie; Tang Lilei

    2011-01-01

    According as the determining method and the assessing criterion,the uncertainty assessing of measure result of tungsten in U 3 O 8 by ICP-AES is researched. With the assessment of each component in detail, the result shows that u rel (sc)> u rel (c)> u rel (F)> u rel (m) by uncertainty contribution. Other uncertainty is random, calculated by repetition. u rel (sc) is contributed to uncertainty mainly. So the general uncertainty is reduced with strict operation to reduce u rel (sc). (authors)

  3. Method for separation of Cs from acid solution dissolving radionuclides and microanalysis of solution with ICP-AES

    International Nuclear Information System (INIS)

    Kanazawa, Toru; Hidaka, Akihide; Kudo, Tamotsu; Nakamura, Takehiko; Fuketa, Toyoshi

    2004-06-01

    The VEGA (Verification Experiments of radionuclides Gas/Aerosol release) program is being performed at JAERI to understand mechanisms of radionuclides release from irradiated fuel during severe accidents. As a part of evaluation in the program, the mass balances of released and deposited FP (Fission Products) onto the test apparatus are estimated from gamma ray measurement for acid solution leached from the apparatus, but short-life nuclides are difficult to be measured because those in the VEGA fuel have been mostly depleted due to cooling for several years. Moreover, the radionuclides without emitting gamma rays and very small quantity of elements cannot be quantified by gamma ray measurement. Therefore, a microanalysis by ICP-AES (Inductively Coupled Plasma - Atomic Emission Spectrometry) for the acid solution leached from VEGA apparatuses is being applied to evaluate the released and deposited masses for those elements. Since Cs-134 and -137, which are major FP dissolved in the solution, have high intensity of gamma ray spectrum, they have to be removed from the solution before the microanalysis in order to avoid contamination of ICP system and to decrease exposure to gamma ray. In this report, methods for separation of Cs from acid solution were reviewed and the applicability of them to the ICP-AES analysis was discussed. The method for Cs separation using the inorganic ion exchanger, AMP (Ammonium Molybdate Phosphate) was applied to the solutions of cold and hot test and the effectiveness was examined. The results showed that more than 99.9% of Cs could be removed from the test solutions, and once removed Sb by AMP was recovered by using a complexing agent such as citric acid. Next, the method was applied to an acid solution leached from VEGA-3 apparatus, and ICP-AES analysis was performed for it. The analysis showed that amount of U, Sr and Zr were successfully quantified. Most of elements to be analyzed were measurable except for Sb, Ag and Sn, although

  4. Multielement determination of major-to-ultratrace elements in salmon egg by ICP-AES and ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Hirotaka; Haraguchi, Hiroki [Nagoya Univ., Graduate School of Engineering, Dept. of Applied Chemistry, Nagoya, Aichi (Japan)

    2002-04-01

    The multielement determination of major-to-ultratrace elements in salmon egg was carried out by ICP-AES and ICP-MS. First, salmon eggs (30 eggs used) were digested with conc. nitric acid and 60% perchloric acid by heating almost to dryness repeatedly. Finally, the residues of salmon eggs were dissolved in 1 M nitric acid and the sample solutions were analyzed by ICP-AES and ICP-MS. About 40 elements could be determined over the concentration range in 9 orders of magnitude. The concentrations of bio-essential elements, such as Zn, Fe, and Cu, in salmon egg were 10-100 times higher than those in human blood serum. In addition, the major-to-ultratrace elements in cell cytoplasm and cell membrane were separately determined in a similar manner to those in whole egg cell. The concentrations of most bio-essential elements were higher in cell cytoplasm than in cell membrane, while those of Fe and Cu were higher in cell membrane than in cell cytoplasm of salmon egg. (author)

  5. ICP/AES radioactive sample analyses at Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Matsuzaki, C.L.; Hara, F.T.

    1986-03-01

    Inductively coupled argon plasma atomic emission spectroscopy (ICP/AES) analyses of radioactive materials at Pacific Northwest Laboratory (PNL) began about three years ago upon completion of the installation of a modified Applied Research Laboratory (ARL) 3560. Funding for the purchase and installation of the ICP/AES was provided by the Nuclear Waste Materials Characterization Center (MCC) established at PNL by the Department of Energy in 1979. MCC's objective is to ensure that qualified materials data are available on waste materials. This paper is divided into the following topics: (1) Instrument selection considerations; (2) initial installation of the simultaneous system with the source stand enclosed in a 1/2'' lead-shielded glove box; (3) retrofit installation of the sequential spectrometer; and (4) a brief discussion on several types of samples analyzed. 1 ref., 7 figs., 1 tab

  6. Integrated Design for Marketing and Manufacturing team: An examination of LA-ICP-AES in a mobile configuration. Final report

    International Nuclear Information System (INIS)

    1994-05-01

    The Department of Energy (DOE) has identified the need for field-deployable elemental analysis devices that are safer, faster, and less expensive than the fixed laboratory procedures now used to screen hazardous waste sites. As a response to this need, the Technology Integration Program (TIP) created a mobile, field-deployable laser ablation-inductively coupled plasma-atomic emission spectrometry (LA-ICP-AES) sampling and analysis prototype. Although the elemental. screening prototype has been successfully field-tested, continued marketing and technical development efforts are required to transfer LA-ICP-AES technology to the commercial sector. TIP established and supported a student research and design group called the Integrated Design for Marketing and Manufacturing (IDMM) team to advance the technology transfer of mobile, field-deployable LA-ICP-AES. The IDMM team developed a conceptual design (which is detailed in this report) for a mobile, field-deployable LA-ICP-AES sampling and analysis system, and reports the following findings: Mobile, field-deployable LA-ICP-AES is commercially viable. Eventual regulatory acceptance of field-deployable LA-ICP-AES, while not a simple process, is likely. Further refinement of certain processes and components of LA-ICP-AES will enhance the device's sensitivity and accuracy

  7. Multielement analytical procedure coupling INAA, ICP-MS and ICP-AES: Application to the determination of major and trace elements in sediment samples of the Bouregreg river (Morocco)

    International Nuclear Information System (INIS)

    Bounouira, H.; CEA - CNRS/UMR, Centre de Saclay, 91 - Gif sur Yvette; Choukri, A.; Hakam, O.K.; Cherkaoui, R.; Gaudry, A.; Delmas, R.; Mariet, C.; Chakiri, S.

    2008-01-01

    Instrumental neutron activation analysis (INAA), inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES) were used for the determination of major and trace elements in sediment samples of the Bouregreg river (Morocco). The reliability of the results was checked, by using IAEA Soil-7 certified reference material. Results obtained by the three techniques were compared to control digestions efficiencies. A general good agreement was found between INAA and both ICP-MS and ICP-AES after alkaline fusion (ICPf). The ICP-MS technique used after acid attack (ICPa) was satisfactory for a few elements. A principal component analysis (PCA) has been used for analyzing the variability of concentrations, and defining the most influential sites with respect to the general variation trends. Three groups of elements could be distinguished. For these groups a normalization of concentrations to the central element concentration (that means Mn, Si or Al) is proposed. (author)

  8. Multielement determination of major-to-ultratrace elements in vegetable samples by ICP-MS and ICP-AES after acid digestion

    Energy Technology Data Exchange (ETDEWEB)

    Hokura, Akiko; Oguri, Sachiko; Matsuura, Hirotaka; Haraguchi, Hiroki [Dept. of Applied Chemistry, Graduate School of Engineering, Nagoya Univ. (Japan)

    2000-06-01

    A multielement determination of major-to-ultratrace elements in vegetable samples was carried out by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Spinach samples (0.5 g) were digested with nitric acid and hydrofluoric acid in a Teflon beaker on a hot plate. The decomposed samples were dissolved in a 1 M ( = mol dm{sup -3}) HNO{sub 3} solution containing internal standard elements (Ge, In, and Re, 10 ppb each), and were subjected to multielement analyses by ICP-AES and ICP-MS. As a result, about 40 elements were successfully determined over a wide concentration range from % to ppb level. Spinach samples grown in different production areas were also analyzed in order to understand the influences of the environmental conditions on growth. Among the major and minor elements, the values of the coefficient of variance (CV) for B, Mg, P, and K were < 20%, and those for Ca, Na, Al, and Mn were higher than 50%. On the other hand, the values of CV for trace and ultratrace elements were significantly high. Furthermore, the present analytical method was also applied to the determination of major-to-ultratrace elements in various vegetable samples (23 species in 11 families); the similarities and differences of the elemental distributions in vegetables were found in the experimental results. (author)

  9. Multielement determination of major-to-ultratrace elements in vegetable samples by ICP-MS and ICP-AES after acid digestion

    International Nuclear Information System (INIS)

    Hokura, Akiko; Oguri, Sachiko; Matsuura, Hirotaka; Haraguchi, Hiroki

    2000-01-01

    A multielement determination of major-to-ultratrace elements in vegetable samples was carried out by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Spinach samples (0.5 g) were digested with nitric acid and hydrofluoric acid in a Teflon beaker on a hot plate. The decomposed samples were dissolved in a 1 M ( = mol dm -3 ) HNO 3 solution containing internal standard elements (Ge, In, and Re, 10 ppb each), and were subjected to multielement analyses by ICP-AES and ICP-MS. As a result, about 40 elements were successfully determined over a wide concentration range from % to ppb level. Spinach samples grown in different production areas were also analyzed in order to understand the influences of the environmental conditions on growth. Among the major and minor elements, the values of the coefficient of variance (CV) for B, Mg, P, and K were < 20%, and those for Ca, Na, Al, and Mn were higher than 50%. On the other hand, the values of CV for trace and ultratrace elements were significantly high. Furthermore, the present analytical method was also applied to the determination of major-to-ultratrace elements in various vegetable samples (23 species in 11 families); the similarities and differences of the elemental distributions in vegetables were found in the experimental results. (author)

  10. Simultaneous multielement analysis of zirconium alloys by chlorination separation of matrix/ICP-AES

    International Nuclear Information System (INIS)

    Kato, Kaneharu

    1990-01-01

    An analytical method combined chlorination separation of matrix with ICP-AES has been developed for reactor grade Zr alloys (Zircaloy-2). A sample (1 g) is taken into a Pt boat and chlorinated with HCl gas of 100 ml/min in a glass reaction tube at ca. 330degC. Matrix Zr of the sample is volatilized and separated as ZrCl 4 . The analytic elements remaining quantitatively as chlorination residue are dissolved in a mixture of mineral acids (6 M HCl 3 ml+conc. HNO 3 0.5 ml+conc. H 2 SO 4 0.2 ml) and diluted to 20 ml with distilled water after filtration. ICP-AES was used for simultaneous multielement determination using a calibration curve method. The present method has the following advantages: simple sample preparation procedure; applicability to any form of samples to determine multielements; simple ICP-AES calibration procedure. This method was successfully applied to the determination of Fe, Ni, Cu, Co, Mn and Pb in the Zr alloys of JAERI CRM's and NBS SRM's. (author)

  11. A study on the determination of phosphorus in Th-U matrix by a high resolution spectroanalyser (ICP-AES)

    International Nuclear Information System (INIS)

    Save, Neeta; Kumar, Neeraj; Jaiswal, Rajesh; Ghosh, Seema; Malav, R.K.; Das, D.K.; Prakash, Amrit; Behere, P.G.; Afzal, Mohd

    2013-01-01

    Phosphorus is present as an impurity in Thoria and constitutes an important chemical specification of the Thoria based fuel. The present paper depicts the importance of determination of phosphorus, which forms an important quality control step during the fabrication of mixed oxide (Th-U)O 2 pellet. A high resolution spectroanalyser using ICP-AES has been used for the determination of Phosphorus in (ThO 2 -3.25%UO 2 ). (author)

  12. Neutron activation analysis and ICP-AES to determine metal traces in antarctic krill. CNEA laboratories participation in the certification of a reference material

    International Nuclear Information System (INIS)

    Smichowski, Patricia N.; Farias, Silvia S.; Resnizky, Sara M.; Marrero, Julieta G.

    1999-01-01

    For the international certification of a reference material based on krill, As and Hg were determined by instrumental neutron activation analysis and Br, Co and Se by radiochemical neutron activation analysis. Inductive coupling plasma atomic emission spectrometry (ICP-AES) was used to determine Cu, Fe, Mn, and Zn. The results, which are in good agreement with those obtained by other laboratories, are discussed

  13. ICP-AES determination of rare earths in zirconium with prior chemical separation of the matrix

    International Nuclear Information System (INIS)

    Rajeswari, B.; Dhawale, B.A.; Page, A.G.; Sastry, M.D.

    2002-01-01

    Zirconium being one of the most important material in nuclear industry used as a fuel cladding in reactors and an additive in advanced fuels necessitates its characterization for trace metallic contents. Zirconium, as refractory in nature as the rare earth elements, has a complex spectrum comprising of several emission lines. Rare earths, which are high neutron absorbers have to be analysed at very low limits. Hence, to achieve the desired limits, the major matrix has to be separated prior to rare earth determination. The present paper describes the method developed for the separation of rare earths from zirconium by solvent extraction using Trioctyl Phosphine Oxide (TOPO) as the extractant followed by their determination using Inductively Coupled Plasma - Atomic Emission Spectrometric (ICP-AES) method. Initially, radiochemical studies were carried out using known amounts of gamma active tracers of 141 Ce, 152-154 Eu, 153 Gd and 95 Zr for optimisation of extraction conditions using Tl- activated NaI detector. The optimum conditions at 0.5 M TOPO/xylene in 6 M HCl so as to achieve a quantitative recovery of rare earth analytes alongwith a near total extraction of zirconium in the organic phase, was further extended to carry out the studies using ICP-AES method. The recovery of rare earths was found to be quantitative within experimental error with a precision better than 10% RSD. (author)

  14. Radiochemical separation and ICP-AES determination of some common metallic elements in ThO2 matrix

    International Nuclear Information System (INIS)

    Adya, V.C.; Hon, N.S.; Bangia, T.R.; Sastry, M.D.; Iyer, R.H.

    1997-01-01

    Radioactive tracer and also ICP-AES studies have been carried out to determine Al, Cd, Ca, Cr, Co, Cu, Mn, Mo and Pd in ThO 2 matrix after chemical separation. Di-2-ethyl-hexyl phosphoric acid/xylene/HNO 3 extraction system was used for quantitative separation of thorium. The recovery of elements as determined by tracers and ICP-AES was found to be quantitative within experimental error. (author). 3 refs., 1 tab

  15. Trace level determination of precious metals in aqueous medium, U, Th and Zr based nuclear materials by ICP-AES and EDXRF - a comparative study

    International Nuclear Information System (INIS)

    Sengupta, Arijit; Thulasidas, S.K.; Natarajan, V.

    2015-01-01

    A comparative study was carried out to determine Ag, Au and Pt in aqueous samples, uranium, zirconium, and thorium based nuclear fuels and associated materials by CCD based ICP-AES and EDXRF. In ICP-AES, the spectral interference of U, Th, Zr matrices on trace level determination of Ag, Au and Pt were studied for different analytical lines of these analytes. The analytical performance of different lines including detection limits, sensitivity, linear dynamic range etc were studied both by ICP-AES and EDXRF. Though EDXRF technique was known its non destructive nature, the overall analytical performance of ICP-AES technique was found to be superior to EDXRF. Based on the spectral contribution from emission rich matrix elements and the analytical performance of different analytical lines of these analytes, a method was developed for direct determination of these analytes by ICP-AES without chemical separation. The method was validated with synthetic samples and compared with EDXRF technique and conventional ICP-AES technique where the major matrix was chemically separated using suitable organic phase containing selective ligands. The ICP-AES method for direct determination of analytes without chemical separation was found to be simple, less time consuming, without generation of organic waste with acceptable analytical performance

  16. Comparision of ICP-OES and MP-AES in determing soil nutrients by Mechlich3 method

    Science.gov (United States)

    Tonutare, Tonu; Penu, Priit; Krebstein, Kadri; Rodima, Ako; Kolli, Raimo; Shanskiy, Merrit

    2014-05-01

    Accurate, routine testing of nutrients in soil samples is critical to understanding soil potential fertility. There are different factors which must be taken into account selecting the best analytical technique for soil laboratory analysis. Several techniques can provide adequate detection range for same analytical subject. In similar cases the choise of technique will depend on factors such as sample throughput, required infrastructure, ease of use, used chemicals and need for gas supply and operating costs. Mehlich 3 extraction method is widely used for the determination of the plant available nutrient elements contents in agricultural soils. For determination of Ca, K, and Mg from soil extract depending of laboratory ICP and AAS techniques are used, also flame photometry for K in some laboratories. For the determination of extracted P is used ICP or Vis spectrometry. The excellent sensitivity and wide working range for all extracted elements make ICP a nearly ideal method, so long as the sample throughput is big enough to justify the initial capital outlay. Other advantage of ICP techniques is the multiplex character (simultaneous acquisition of all wavelengths). Depending on element the detection limits are in range 0.1 - 1000 μg/L. For smaller laboratories with low sample throughput requirements the use of AAS is more common. Flame AAS is a fast, relatively cheap and easy technique for analysis of elements. The disadvantages of the method is single element analysis and use of flammable gas, like C2H2 and oxidation gas N2O for some elements. Detection limits of elements for AAS lays from 1 to 1000 μg/L. MP-AES offers a unique alternative to both, AAS and ICP-OES techniques with its detection power, speed of analysis. MP-AES is quite new, simple and relatively inexpensive multielemental technique, which is use self-sustained atmospheric pressure microwave plasma (MP) using nitrogen gas generated by nitrogen generator. Therefore not needs for argon and

  17. Determination of Boron in Zircaloy by using ICP-AES and Colorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong-Goo; Pyo, Hyung-Ryul; Choi, Kwang-Soon; Han, Sun-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2007-10-15

    Zircaloy has been being widely used in the nuclear industry because of the low cross section of Zirconium against a thermal neutron. Accurate composition data of Zircaloy for Hf, B, and so on having a high cross section against thermal neutron is important to use it as a nuclear material. Accordingly proper determination methods of these elements in Zircaloy are needed. In this study, the application of two methods, ICP-AES and a colorimetry using methylene blue were investigated in order to establish a proper analysis method of Boron in the range from tens to hundreds ug B/g sample of Zircaloy.

  18. Determination of Boron in Zircaloy by using ICP-AES and Colorimetry

    International Nuclear Information System (INIS)

    Kim, Jong-Goo; Pyo, Hyung-Ryul; Choi, Kwang-Soon; Han, Sun-Ho

    2007-01-01

    Zircaloy has been being widely used in the nuclear industry because of the low cross section of Zirconium against a thermal neutron. Accurate composition data of Zircaloy for Hf, B, and so on having a high cross section against thermal neutron is important to use it as a nuclear material. Accordingly proper determination methods of these elements in Zircaloy are needed. In this study, the application of two methods, ICP-AES and a colorimetry using methylene blue were investigated in order to establish a proper analysis method of Boron in the range from tens to hundreds ug B/g sample of Zircaloy

  19. Multielement determination and speciation of major-to-trace elements in black tea leaves by ICP-AES and ICP-MS with the aid of size exclusion chromatography

    International Nuclear Information System (INIS)

    Matsuura, Hirotaka; Hokura, Akiko; Katsuki, Fumie; Itoh, Akihide; Haraguchi, Hiroki

    2001-01-01

    A multielement determination of major-to-trace elements in black tea leaves and their tea infusions was carried out by ICP-AES (inductively coupled plasma atomic emission spectrometry) and ICP-MS (inductively coupled plasma mass spectrometry). Tea infusions were prepared as usual tea beverage by brewing black tea leaves in boiling water for 5 min. About 40 elements in tea leaves and tea infusions could be determined over the wide concentration range in 8 orders of magnitude. The extraction efficiency of each element was estimated as the ratio of its concentration in tea infusions to that in tea leaves. From the experimental results for the extraction efficiencies, the elements in black tea leaves were classified into three characteristic groups: (i) highly-extractable elements (>55%): Na, K, Co, Ni, Rb, Cs and Tl, (ii) moderately-extractable elements (20-55%): Mg, Al, P, Mn and Zn, and (iii) poorly-extractable elements (<20%): Ca, Fe, Cu, Sr, Y, Zr, Mo, Sn, Ba and lanthanoid elements. Furthermore, speciation of major-to-trace elements in tea infusions was performed by using a combined system of size exclusion chromatography (SEC) and ICP-MS (or ICP-AES). As a result, many diverse elements were found to be present as complexes associated with large organic molecules in tea infusions. (author)

  20. Determination of organic phosphorous in oil production waters by ICP-AES and ICP-MS after preconcentration on silica immobilized C{sub 18}; Determinacao de fosforo organico em aguas de producao petrolifera por ICP-AES e ICP-MS apos pre-concentracao em coluna de silica C{sub 18}

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Anderson Araujo; Miekeley, Norbert; Silveira, Carmem Lucia Porto da [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil). Dept. de Quimica; Bezerra, Maria Carmem Moreira [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    1998-10-01

    Results on the optimization analytical methods for the determination of phosphorous in phosphino-poly carboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination in necessary. In this work, mini columns of silica immobilized C{sub 18} were used. Optimization of the separation step resulted in the following working conditions: (1) pre washing of the column with methanol (80% v/v); (2) use of a flow rate of 5 m L/min and 10 m L/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 m L of buffer of H{sub 3} BO{sub 3}/Na OH (0.05 M, p H 9) with a flow rate of 1 m L/min. Sample detection limits (3{sigma}) for different combinations of nebulizers and spectrometric methods, based on 10 m L water aliquots, are: ICP-AES-Cross flow (47 mg/L) and Ultrasonic (18 {mu}g/L); ICP-M S-Cross flow (1.2 {mu}g/L) and Ultrasonic (0.5 {mu}g/L). Typical recoveries of organic phosphorous are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well N A 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods., resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts. (author)

  1. ICP-AES analysis of trace elements in serum from animals fed with irradiated food

    International Nuclear Information System (INIS)

    Huang Zongzhi; Zhou Hongdi

    1986-01-01

    A method of trace element analysis by ICP-AES in serum from animals fed with irradiated food is described. In order to demonstrate that irradiated food is suitable for human consumption, it is necessary to perform an experiment of animal feeding with these food before use for human. Trace element analysis in animal serum could provide an actual evidence for further human consumption study. 53 serum samples of the rats fed with irradiated food were obtained. After ashed and solved, ICP-AES analysis has been used for determining 20 trace elements in specimen solution. The detection limitation is in the range of 10 -2 -10 -3 ppm for different elements. The recovery of elements is from 70.08% to 98.28%. The relative standard deviation is found to be 0.71% to 11.52%

  2. A scheme for the complete elemental characterisation of brannerite mineral using ICP-AES

    International Nuclear Information System (INIS)

    Premadas, A.; Bose, Roopa

    2013-01-01

    Brannerite occurs along with other refractory minerals in pegmatite veins. Literature survey indicates lack of systematic and detailed chemical analysis procedure for brannerites. This paper report suitable sample decomposition procedures, yielding stable sample solution, suitable for the ICP-AES determination of major, minor and certain trace elements normally associated with brannerite mineral. Three different simple decomposition procedures such as (i) acid digestion (ii) fusion with lithium metaborate (iii) fusion with mixture of tetra sodium pyrophosphate and monosodium dihydrogen phosphate are used to obtain the sample solution for elemental analysis. In presence of higher concentrations of uranium and titanium, the major elements in brannerite mineral, a detailed study of the influence of uranium and titanium on ICP-AES determination of other elements, three commonly used emission lines of each element was carried out. The REEs, Y, Sc and Th have been determined after the removal of major matrix elements using oxalate precipitation. The accuracy of the proposed procedures is established by analyzing synthetic brannerite samples prepared by mixing high purity oxides or chlorides in a proportion similar to natural brannerite samples. The results indicate the method is accurate. The reproducibility studies carried out on one sample shows the % RSD varied from 2 to 5%. (author)

  3. The calibration of XRF polyethylene reference materials with k 0-NAA and ICP-AES

    International Nuclear Information System (INIS)

    Swagten, Josefien; Bossus, Daniel; Vanwersch, Hanny

    2006-01-01

    Due to the lack of commercially available polyethylene reference materials for the calibration of X-ray fluorescence spectrometers (XRF), DSM Resolve, in cooperation with PANalytical, prepared and calibrated such a set of standards in 2005. The reference materials were prepared based on the addition of additives to virgin polyethylene. The mentioned additives are added to improve the performance of the polymers. The elements present in additives are tracers for the used additives. The reference materials contain the following elements: F, Na, Mg, Al, Si, P, S, Ca, Ti and Zn in the concentration range of 5 mg/kg for Ti, up to 600 mg/kg for Mg. The calibration of the reference materials, including a blank, was performed using inductively coupled plasma atomic emission spectrometry (ICP-AES) and Neutron Activation Analysis (k 0 -NAA). ICP-AES was used to determine the elements Na, Mg, Al, P, Ca, Ti and Zn whereas k 0 -NAA was used for F, Na, Mg, Al, Ca, Ti and Zn. Over the complete concentration range, a good agreement of the results was found between the both techniques. This project has shown that within DSM Resolve, it is possible to develop and to calibrate homogenous reference materials for XRF

  4. Chemical separation and ICP-AES determination of rare earths in Al2O3 matrix

    International Nuclear Information System (INIS)

    Argekar, A.A.; Kulkarni, M.J.; Page, A.G.; Manchanda, V.K.

    2005-01-01

    A chemical separation-ICP-AES method has been developed for determination of rare earths in alumina matrix. The quantitative separation of rare earths has also been confirmed using radiotracers. (author)

  5. An ICP AES method for determination of dysprosium and terbium in high purity yttrium oxide

    International Nuclear Information System (INIS)

    Rupawate, V.H.; Hareendran, K.N.; Roy, S.B.

    2011-01-01

    High purity yttrium finds interesting application in astronavigation, luminescence, nuclear energy and metallurgical industries. Most of these applications require yttrium oxide of highest purity. Consequently there is a need for production of high purity yttrium oxide. Separation and purification of yttrium from other rare earths is a challenging task due to their close chemical properties. Liquid-liquid extraction and ion exchange have been widely used in the production of yttrium oxide of highest purity. Determination of impurities, especially other rare earths, in ppm level is required for process development and chemical characterization of the high purity Y 2 O 3 . Many methods have been described in literature. However since the advent of ICP AES much work in this area has been carried out by this technique. This paper describes the work done for determination of dysprosium (Dy) and terbium (Tb) in yttrium oxide using a high resolution sequential ICP AES. Emission spectra of rare earth elements are very complex and due to this complexity it is important to select spectral interference free analyte lines for determination of rare earths in rare earth matrix. For the determination of Dy and Tb in Y 2 O 3 , sensitive lines of Dy and Tb are selected from the instrument wavelength table and spectral interference free emission lines for the determination is selected by scanning around the selected wavelengths using 5 g/L Y solution and 5 mg/L standard solutions of Dy and Tb prepared in 4% nitric acid. It is found 353.170 nm line of Dy and 350.917 nm line Tb is suitable for quantitative determination. The signal to background ratio increases with increase in matrix concentration, i.e. from 1 to 5 mg/L. The optimum forward power is determined and it is found to be 1100W for Dy and 1000W for Tb. The instrument is calibrated using matrix matched standards containing 5g/L of Y matrix. Samples are dissolved in nitric acid and Y concentration is maintained at 5g/L. Two

  6. Quantification of immobilized Candida antarctica lipase B (CALB) using ICP-AES combined with Bradford method.

    Science.gov (United States)

    Nicolás, Paula; Lassalle, Verónica L; Ferreira, María L

    2017-02-01

    The aim of this manuscript was to study the application of a new method of protein quantification in Candida antarctica lipase B commercial solutions. Error sources associated to the traditional Bradford technique were demonstrated. Eight biocatalysts based on C. antarctica lipase B (CALB) immobilized onto magnetite nanoparticles were used. Magnetite nanoparticles were coated with chitosan (CHIT) and modified with glutaraldehyde (GLUT) and aminopropyltriethoxysilane (APTS). Later, CALB was adsorbed on the modified support. The proposed novel protein quantification method included the determination of sulfur (from protein in CALB solution) by means of Atomic Emission by Inductive Coupling Plasma (AE-ICP). Four different protocols were applied combining AE-ICP and classical Bradford assays, besides Carbon, Hydrogen and Nitrogen (CHN) analysis. The calculated error in protein content using the "classic" Bradford method with bovine serum albumin as standard ranged from 400 to 1200% when protein in CALB solution was quantified. These errors were calculated considering as "true protein content values" the results of the amount of immobilized protein obtained with the improved method. The optimum quantification procedure involved the combination of Bradford method, ICP and CHN analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Tandem on-line continuous separations for atomic spectroscopic indirect analysis: iodide determination by ICP-AES

    International Nuclear Information System (INIS)

    Garcia, A.M.; Sanchez Uria, J.E.; Sanz-Medel, A.; Quintero Ortega, M.C.; Bautista, J.C.

    1992-01-01

    A sensitive and selective indirect determination of iodide by inductively coupled plasma emission spectrometry (ICP-AES) based on the principle of tandem on-line continuous separations as an alternative means of introducing samples into plasmas is proposed. Iodide is continuously extracted as an ion-pair into xylene by mixing the sample with Hg(II) and dipyridil solutions. The organic phase (containing the analyte in [Hg(Dipy) 2 ]I 2 form) is on-line continuously mixed with NaBH 4 (in DMF) and acetic acid solutions. Mercury vapour continuously generated from this organic phase is separated in a classical U-type gas-liquid separation device. The system has been optimized for the continuous extraction of KI, for the direct generation of cold mercury vapour from xylene and for the final ICP-AES determination of mercury. The optimised method has been applied to the determination of iodide (detection limit 20 ng/ml of iodide) in table salt and in synthetic samples. Very good agreement between found and certified results was observed. The usefulness and convenience of such alternative sample chemical pretreatment/presentation to the ICP is thus demonstrated for indirect determinations to be carried out by atomic spectroscopy methods. (authors)

  8. A new approach for the beryl mineral decomposition: elemental characterisation using ICP-AES and FAAS

    International Nuclear Information System (INIS)

    Nathan, Usha; Premadas, A.

    2013-01-01

    A new approach for the beryl mineral sample decomposition and solution preparation method suitable for the elemental analysis using ICP-AES and FAAS is described. For the complete sample decomposition four different decomposition procedures are employed such as with (i) ammonium bi-fluoride alone (ii) a mixture of ammonium bi-fluoride and ammonium sulphate (iii) powdered mixture of NaF and KHF 2 in 1: 3 ratio, and (iv) acid digestion treatment using hydrofluoric acid and nitric acid mixture, and the residue fused with a powdered mixture NaF and KHF 2 . Elements like Be, Al, Fe, Mn, Ti, Cr, Ca, Mg, and Nb are determined by ICP-AES and Na, K, Rb and Cs are determined by FAAS method. Fusion with 2g ammonium bifluoride flux alone is sufficient for the complete decomposition of 0.400 gram sample. The values obtained by this decomposition procedure are agreed well with the reported method. Accuracy of the proposed method was checked by analyzing synthetic samples prepared in the laboratory by mixing high purity oxides having a chemical composition similar to natural beryl mineral. It indicates that the accuracy of the method is very good, and the reproducibility is characterized by the RSD 1 to 4% for the elements studied. (author)

  9. Mineral distribution in rice: Measurement by Microwave Plasma Atomic Emission Spectroscopy (MP-AES)

    International Nuclear Information System (INIS)

    Ramos, Nerissa C.; Ramos, R.G.A.; Quirit, L.L.; Arcilla, C.A.

    2015-01-01

    Microwave Plasma Atomic Emission Spectroscopy (MP-AES) is a new technology with comparable performance and sensitivity to Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). Both instrument use plasma as the energy source that produces atomic and ionic emission lines. However, MP-AES uses nitrogen as the plasma gas instead of argon which is an additional expense for ICP-OES. Thus, MP-AES is more economical. This study quantified six essential minerals (Se, Zn, Fe, Cu, Mn and K) in rice using MP-AES. Hot plate digestion was used for sample extraction and the detection limit for each instrument was compared with respect to the requirement for routine analysis in rice. Black, red and non-pigmented rice samples were polished in various intervals to determine the concentration loss of minerals. The polishing time corresponds to the structure of the rice grains such as outer bran layer (0 to 15), inner bran layer (15 to 30), outer endosperm layer (30 to 45), and middle endosperm layer (45 to 60). Results of MP-AES analysis showed that black rice had all essential materials (except K) in high concentration at the outer bran layer. The red and non-pigmented rice samples on the other hand, contained high levels of Se, Zn, Fe, and Mn in the whole bran portion. After 25 seconds, the mineral concentrations remained constant. The concentration of Cu however, gave consistent value in all polishing intervals, hence Cu might be located in the inner endosperm layer. Results also showed that K was uniformly distributed in all samples where 5% loss was consistently observed for every polishing interval. Therefore, the concentration of K was also affected by polishing time. Thus, the new MP-AES technology with comparable performance to ICP-OES is a promising tool for routine analysis in rice. (author)

  10. Determination of the performance characteristics of a method for the measurement of total phosphorus in groundwater with the PE Optima 3000 XL ICP-AES

    NARCIS (Netherlands)

    Kohlmeyer U; Breugem PM; Boer JLM de; LAC

    1996-01-01

    Dit rapport behandelt de prestatiekenmerken van een methode voor de bepaling van totaal-fosfor in grondwater met behulp van ICP-AES met een axiaal plasma (Perkin-Elmer Optima 3000 XL). Met de reeds bestaande methode 'TotP' werden de volgende prestatiekenmerken vastgesteld:

  11. Sample introduction systems for the analysis of liquid microsamples by ICP-AES and ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Todoli, Jose L. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, 03080 Alicante (Spain)]. E-mail: jose.todoli@ua.es; Mermet, Jean M. [Spectroscopy Forever, 01390 Tramoyes (France)

    2006-03-15

    There are many fields in which the available sample volume is the limiting factor for an elemental analysis. Over the last ten years, sample introduction systems used in plasma spectrometry (i.e., Inductively Coupled Plasma Atomic Emission Spectrometry, ICP-AES, and Mass Spectrometry, ICP-MS) have evolved in order to expand the field of applicability of these techniques to the analysis of micro- and nanosamples. A full understanding of the basic processes occurring throughout the sample introduction system is absolutely necessary to improve analytical performance. The first part of the present review deals with fundamental studies concerning the different phenomena taking place from aerosol production to analyte excitation/ionization when the liquid consumption rate does not exceed 100 {mu}l/min. Existing sample introduction systems are currently far from the ideal and a significant effort has been made to develop new and efficient devices. Different approaches for continuously introducing small sample volumes (i.e., microsamples) have been reviewed and compared in the present work. Finally, applications as well as basic guidelines to select the best sample introduction system according to the sample particularities are given at the end of this review.

  12. Sample introduction systems for the analysis of liquid microsamples by ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Todoli, Jose L.; Mermet, Jean M.

    2006-01-01

    There are many fields in which the available sample volume is the limiting factor for an elemental analysis. Over the last ten years, sample introduction systems used in plasma spectrometry (i.e., Inductively Coupled Plasma Atomic Emission Spectrometry, ICP-AES, and Mass Spectrometry, ICP-MS) have evolved in order to expand the field of applicability of these techniques to the analysis of micro- and nanosamples. A full understanding of the basic processes occurring throughout the sample introduction system is absolutely necessary to improve analytical performance. The first part of the present review deals with fundamental studies concerning the different phenomena taking place from aerosol production to analyte excitation/ionization when the liquid consumption rate does not exceed 100 μl/min. Existing sample introduction systems are currently far from the ideal and a significant effort has been made to develop new and efficient devices. Different approaches for continuously introducing small sample volumes (i.e., microsamples) have been reviewed and compared in the present work. Finally, applications as well as basic guidelines to select the best sample introduction system according to the sample particularities are given at the end of this review

  13. Monitoring of some heavy metal in egypt using different spectroscopic technique ICP-AES and AAS-GF

    International Nuclear Information System (INIS)

    El-Sayed, A.A.

    2005-01-01

    Heavy metals include both toxic and/or non toxic elements egyptian aquatic environment were monitored using inductivly coupled plasma-atomic emission spectroscopy; ICP-AES and graphite furnace-atomic absorption spectroscopy; GF-AAS. Water and aquatic weeds (waterhyathins) are of different categories specified for such monitoring form the canals. The locations of sampling sites the river nile in egypt. These sites were chosen based on the industrial activity comparing to the cleansite and the other cultivated one. Bioavailability and related effects were defined so as to specify actually the higher concentration more contaminated areas

  14. Preconcentration of uranium, thorium, zirconium, titanium, molybdenum and vanadium with oxine supported on microcrystalline naphthalene and their determinations by ICP-AES

    International Nuclear Information System (INIS)

    Kumar, Naveen; Kumar, Sanjay; Kumar, Vijay; Nandakishore, S.S.; Bangroo, P.N.

    2013-01-01

    As an effective technique for separation and preconcentration of trace elements, solid-liquid extraction with microcrystalline naphthalene has received great attention in recent years. The application of the adsorption of the metal complexes on microcrystalline naphthalene has greatly enhanced the utility of solid-liquid extraction in trace analysis. A survey of the literature revealed that single element detection techniques such as spectrophotometry, atomic absorption spectrometry, and polarography were mostly combined with this separation method. However, multi-element simultaneous detection techniques, like ICP-AES and ICP-MS were seldom used as the detectors in this solid-liquid extraction method. The aim of this work was to attempt to adopt the reagent oxine for the separation and subsequent determination of U, Th, Zr, Ti, Mo and V by ICP-AES, after adsorption of their oxinate complexes on microcrystalline naphthalene

  15. Estimation of boron, cadmium and cobalt at trace level in magnesium metal using ICP-AES method

    International Nuclear Information System (INIS)

    Patil, P.B.; Surya Prakash Rao, A.; Dixit, V.S.

    2002-01-01

    A method is established for the analysis of B, Cd and Co in the magnesium metal using ICP-AES technique in the range 1-50 ppm. Magnesium granules were dissolved in minimum amount of dilute nitric acid and the resultant solution is aspirated through ICP Nebulizer as nitrates Using various concentrations of matrix material 40, 20, 10 and 5 (mg/ml) were attempted to study the matrix effects on the above analytical elements. The optimum matrix concentration 20 mg/ml gave adequate detection limit of 1 ppm. The standard deviation of this method lies ∼ 1-3%. (author)

  16. Spectral interference of zirconium on 24 analyte elements using CCD based ICP-AES technique

    International Nuclear Information System (INIS)

    Adya, V.C.; Sengupta, Arijit; Godbole, S.V.

    2014-01-01

    In the present studies, the spectral interference of zirconium on different analytical lines of 24 critical analytes using CCD based ICP-AES technique is described. Suitable analytical lines for zirconium were identified along with their detection limits. The sensitivity and the detection limits of analytical channels for different elements in presence of Zr matrix were calculated. Subsequently analytical lines with least interference from Zr and better detection limits were selected for their determinations. (author)

  17. Microwave assisted extraction for trace element analysis of plant materials by ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Borkowska-Burnecka, J. [Wroclaw Univ. (Poland). Inst. Chemii

    2000-11-01

    Application of microwave assisted extraction for the decomposition and dissolution of plant samples for trace metal determination by ICP-AES was examined. Dried onion, leaves of spinach beet and three reference materials CTA-OTL-1, CTA-VTL-2 and CL-1 were analyzed. Water, EDTA and hydrochloric acid (0.01, 0.10 and 1.0 M, respectively) were used as leaching solutions. The extraction efficiency was investigated by comparison of the results with those obtained after microwave wet digestion. HCl was found to be very suitable for quantitative extraction of B, Ba, Cd, Cu, Mn, Ni, Pb, Sr and Zn from the samples. For reference materials, the measured concentrations are well consistent with the certified values. The use of EDTA led to a complete extraction of B, Cd, Ni, Pb, Sr and Zn. Water was found to be a good leaching solution for boron. For extraction with HCl and EDTA, the RSD values for the concentrations measured were below 8% for most of the elements. (orig.)

  18. Microwave assisted extraction for trace element analysis of plant materials by ICP-AES.

    Science.gov (United States)

    Borkowska-Burnecka, J

    2000-11-01

    Application of microwave assisted extraction for the decomposition and dissolution of plant samples for trace metal determination by ICP-AES was examined. Dried onion, leaves of spinach beet and three reference materials CTA-OTL-1, CTA-VTL-2 and CL-1 were analyzed. Water, EDTA and hydrochloric acid (0.01, 0.10 and 1.0 M, respectively) were used as leaching solutions. The extraction efficiency was investigated by comparison of the results with those obtained after microwave wet digestion. HCl was found to be very suitable for quantitative extraction of B, Ba, Cd, Cu, Mn, Ni, Pb, Sr and Zn from the samples. For reference materials, the measured concentrations are well consistent with the certified values. The use of EDTA led to a complete extraction of B, Cd, Ni, Pb, Sr and Zn. Water was found to be a good leaching solution for boron. For extraction with HCl and EDTA, the RSD values for the concentrations measured were below 8% for most of the elements.

  19. Evaluation of Wet Chemical ICP-AES Elemental Analysis Methods using Simulated Hanford Waste Samples-Phase I Interim Report

    International Nuclear Information System (INIS)

    Coleman, Charles J.; Edwards, Thomas B.

    2005-01-01

    The wet chemistry digestion method development for providing process control elemental analyses of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Melter Feed Preparation Vessel (MFPV) samples is divided into two phases: Phase I consists of: (1) optimizing digestion methods as a precursor to elemental analyses by ICP-AES techniques; (2) selecting methods with the desired analytical reliability and speed to support the nine-hour or less turnaround time requirement of the WTP; and (3) providing baseline comparison to the laser ablation (LA) sample introduction technique for ICP-AES elemental analyses that is being developed at the Savannah River National Laboratory (SRNL). Phase II consists of: (1) Time-and-Motion study of the selected methods from Phase I with actual Hanford waste or waste simulants in shielded cell facilities to ensure that the methods can be performed remotely and maintain the desired characteristics; and (2) digestion of glass samples prepared from actual Hanford Waste tank sludge for providing comparative results to the LA Phase II study. Based on the Phase I testing discussed in this report, a tandem digestion approach consisting of sodium peroxide fusion digestions carried out in nickel crucibles and warm mixed-acid digestions carried out in plastic bottles has been selected for Time-and-Motion study in Phase II. SRNL experience with performing this analytical approach in laboratory hoods indicates that well-trained cell operator teams will be able to perform the tandem digestions in five hours or less. The selected approach will produce two sets of solutions for analysis by ICP-AES techniques. Four hours would then be allocated for performing the ICP-AES analyses and reporting results to meet the nine-hour or less turnaround time requirement. The tandem digestion approach will need to be performed in two separate shielded analytical cells by two separate cell operator teams in order to achieve the nine-hour or less turnaround

  20. Separation, preconcentration and estimation of rare earth and trace elements by inductively coupled plasma-atomic emission spectrometry (ICP-AES) in thorium matrices

    International Nuclear Information System (INIS)

    Chakraborty, Prithwish; Kumar Vijay; Durani, Smeer; Satyanarayana, K.

    2007-01-01

    A simple, sensitive and efficient method is developed for the separation of Rare earth elements (REEs) La-Lu, and Y and some trace elements Cd, Co, Cr, Cu, Ni,V, Zn from thorium matrix and their subsequent estimations by ICP-AES. In thorium-rich geological samples, the estimation of REE's by ICP-AES suffers from the spectral interferences due to the presence of excess of Th. In the proposed method, thorium is separated from the matrix by the solvent extraction. To optimize the separation, of REEs and trace elements from Th matrix, synthetic mixture solutions was prepared containing Th, REEs and trace elements maintaining different acidic conditions (1M, 2M, 4M, 6M, 8M and 10M HNO 3 and 2M, 4M, 6M and 8M HCl) and each solution was subjected to solvent extraction. The solvent extraction was carried out using a mixture of di-2-ethylhexyl phosphoric acid (in 30 % Toluene) and 1- pentanol in the ratio of 5:1. The aqueous phase containing the required elements was evaporated to dryness and an acidity of 5% HCl is maintained in final volume. Solutions were analysed by ICP-AES and the quantitative recovery of REEs and trace elements were obtained at 6M HNO 3 acidity. The developed method was applied to the certified standard reference material: IGS-36 and the values obtained were comparable with the certified values. The method was also applied to the real time monazite sample and the recovery was quantitative. Corrections have been applied for the REEs inter-elemental interferences in ICP-AES. (author)

  1. Determination of Nb and Zr in U-Nb-Zr alloys by ICP-AES

    International Nuclear Information System (INIS)

    Wang Cuiping; Dong Shizhe; Li Lin; He Meiying

    2003-01-01

    The U-Nb-Zr alloy sample is dissolved by HNO 3 , H 2 O 2 and HF, and the contents of Nb and Zr in the sample are determined on the JY-70 II type ICP-AES by using the internal standard synchronous dilution method. The range of determination is 1%-10% and 0.33%-3.33%, respectively for Nb and Zr. The relative standard deviation is better than 3.2% for Nb, and 2.5% for Zr. The method is rapid and convenient for determining Nb and Zr in U-Nb-Zr alloy sample

  2. Determinação de fósforo orgânico em águas de produção petrolífera por ICP- AES e ICP- MS após pré-concentração em coluna de sílica-C18 Determination of organic phosphorus in oil production waters by ICP-AES and ICP-MS after preconcentration on silica immobilized C18

    Directory of Open Access Journals (Sweden)

    Anderson Araújo Rocha

    1998-10-01

    Full Text Available Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA, used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1 prewashing of the column with methanol (80% v/v; (2 use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3 final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9 with a flow rate of 1 mL/min. Sample detection limits (3s for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L and Ultrasonic (18 mug/L; ICP-MS -Cross flow (1.2 mug/L, Cyclonic (0.7 mug/L and Ultrasonic (0.5 mug/L. Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts.

  3. Potassium Stable Isotopic Compositions Measured by High-Resolution MC-ICP-MS

    Science.gov (United States)

    Morgan, Leah E.; Lloyd, Nicholas S.; Ellam, Robert M.; Simon, Justin I.

    2012-01-01

    Potassium isotopic (K-41/K-39) compositions are notoriously difficult to measure. TIMS measurements are hindered by variable fractionation patterns throughout individual runs and too few isotopes to apply an internal spike method for instrumental mass fractionation corrections. Internal fractionation corrections via the K-40/K-39 ratio can provide precise values but assume identical K-40/K-39 ratios (e.g. 0.05% (1sigma) in [1]); this is appropriate in some cases (e.g. identifying excess K-41) but not others (e.g., determining mass fractionation effects and metrologically traceable isotopic abundances). SIMS analyses have yielded measurements with 0.25% precisions (1sigma) [2]. ICP-MS analyses are significantly affected by interferences from molecular species such as Ar-38H(+) and Ar-40H(+) and instrument mass bias. Single collector ICP-MS instruments in "cold plasma" mode have yielded uncertainties as low as 2% (1sigma, e.g. [3]). Although these precisions may be acceptable for some concentration determinations, they do not resolve isotopic variation in terrestrial materials. Here we present data from a series of measurements made on the Thermo Scientific NEPTUNE Plus multi-collector ICP-MS that demonstrate the ability to make K-41/K-39 ratio measurements with 0.07% precisions (1sigma). These data, collected on NIST K standards, indicate the potential for MC-ICP-MS measurements to look for K isotopic variations at the sub-permil level. The NEPTUNE Plus can sufficiently resolve 39K and 41K from the interfering 38ArH+ and 40ArH+ peaks in wet cold plasma and high-resolution mode. Measurements were made on small but flat, interference-free, plateaus (ca. 50 ppm by mass width for K-41). Although ICP-MS does not yield accurate K-41/K-39 values due to significant instrumental mass fractionation (ca. 6%), this bias can be sufficiently stable over the time required for several measurements so that relative K-41/K-39 values can be precisely determined via sample

  4. Determination of traces of thorium in ammonium/sodium diuranate by ICP-AES method

    International Nuclear Information System (INIS)

    Nair, V.R.; Kartha, K.N.M.

    1999-01-01

    Full text: Indian Rare Earths Ltd., Alwaye, produces ammonium diuranate from the thorium concentrate, obtained during monazite processing. This process involves a series of steps. The final uranium product obtained always contains microgram amounts of thorium as impurity. An analytical procedure has been standardised for the estimation of microgram amounts of thorium in ammonium/sodium diuranate. The method involves solvent extraction of uranium by using a tertiary amine followed by the determination of thorium by ICP-AES method in the raffinate. The recoveries of thorium were checked by standard addition to the uranium matrix. Limit of detection is adequate for the analysis of nuclear grade material

  5. Zinc, lead and copper in human teeth measured by induced coupled argon plasma atomic emission spectroscopy (ICP-AES)

    Energy Technology Data Exchange (ETDEWEB)

    Chew, L.T.; Bradley, D.A. E-mail: D.A.Bradley@exeter.ac.uk; Mohd, Y.; Jamil, M

    2000-11-15

    Inductively Coupled Argon Plasma Atomic Emission Spectroscopy (ICP-AES) has been used to determine Pb, Zn and Cu levels in 47 exfoliated human teeth (all of which required extraction for orthodontic reasons). Lead concentrations for the group were 1.7 {mu}g (g tooth mass){sup -1} to 40.5 {mu}g (g tooth mass){sup -1}, with a median of 9.8 {mu}g (g tooth mass){sup -1}. A median lead level in excess of the group value was found for the teeth of six lorry drivers who were included in the study. A more significant enhancement was found for the seven subjects whose age was in excess of 60 years. The median values for Zn and Cu were 123.0 and 0.6 {mu}g (g tooth mass){sup -1} respectively. Present values for tooth-Zn are lower than published data for other ethnic groups.

  6. Elemental analysis of oum er rbia moroccan river-water Using icp-aes and chromatography

    International Nuclear Information System (INIS)

    Zahry, F.; Bounakhla, M.; Labraimi, M.; Moutte, J.; Bilal, E.

    2001-01-01

    The analysis of water and suspended particulate matter (SPM) from Oum er Rbia Moroccan river for the content of 22 elements has been performed utilizing ICP-AES and chromatography methods. MPS samples were dissolved in nitric acid. The element analyzed are : Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Br, Ba and Pb. The detection limits are sufficient for most of the elements to be determined. Results were assessed for the accuracy by the analysis of a multi-elemental standard. The results for most of the elements obtained were accurate to about 2-15%. The objective of the analysis were to determine the geochemical areas on this river, to explain the mechanisms of sediment transport and nevertheless, to assess the pollution of the river by human activities. 48 samples were collected along the river, between its source in meddle atlas and the Atlantic ocean at Azemour city

  7. Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES

    International Nuclear Information System (INIS)

    Barciela, Julia; Vilar, Manuela; Garcia-Martin, Sagrario; Pena, Rosa M.; Herrero, Carlos

    2008-01-01

    In this work several pre-treatment methods were studied for metal (Na, K, Mg, Cu and Ca) determination in Orujo spirit samples using inductively coupled plasma atomic emission spectrometry (ICP-AES). Dilution, digestion, evaporation, and cryogenic desolvatation techniques were comparatively evaluated. Because of their analytical characteristics, digestion and evaporation with nitrogen current were found to be appropriate procedures for the determination of metals in alcoholic spirit samples. Yet, if simplicity and application time are to be considered, the latter-evaporation in a water bath with a nitrogen current-stands out as the optimum procedure for any further determinations in Orujo samples by ICP-AES. Low detection levels and wide linear ranges (sufficient to determine these metals in the samples studied) were achieved for each metal. The recoveries (in the 97.5-100.5% range) and the precision (R.S.D. lower than 5.6%) obtained were also satisfactory. The selected procedure was applied to determine the content of metals in 80 representative Galician Orujo spirit samples with and without a Certified Brand of Origin (CBO) which had been produced using different distillation systems. The metal concentrations ranged between 0.37 and 79.7 mg L -1 for Na, -1 for K, 0.02-4.83 mg L -1 for Mg content, -1 for Cu and 0.03-13.10 mg L -1 for Ca

  8. Determination of aluminium in groundwater samples by GF-AAS, ICP-AES, ICP-MS and modelling of inorganic aluminium complexes.

    Science.gov (United States)

    Frankowski, Marcin; Zioła-Frankowska, Anetta; Kurzyca, Iwona; Novotný, Karel; Vaculovič, Tomas; Kanický, Viktor; Siepak, Marcin; Siepak, Jerzy

    2011-11-01

    The paper presents the results of aluminium determinations in ground water samples of the Miocene aquifer from the area of the city of Poznań (Poland). The determined aluminium content amounted from aluminium determinations were performed using three analytical techniques: graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The results of aluminium determinations in groundwater samples for particular analytical techniques were compared. The results were used to identify the ascent of ground water from the Mesozoic aquifer to the Miocene aquifer in the area of the fault graben. Using the Mineql+ program, the modelling of the occurrence of aluminium and the following aluminium complexes: hydroxy, with fluorides and sulphates was performed. The paper presents the results of aluminium determinations in ground water using different analytical techniques as well as the chemical modelling in the Mineql+ program, which was performed for the first time and which enabled the identification of aluminium complexes in the investigated samples. The study confirms the occurrence of aluminium hydroxy complexes and aluminium fluoride complexes in the analysed groundwater samples. Despite the dominance of sulphates and organic matter in the sample, major participation of the complexes with these ligands was not stated based on the modelling.

  9. Determination of platinum group metals by ICP-AES in environmental samples after preconcentration

    International Nuclear Information System (INIS)

    Vlasankova, R.; Sommer, L.

    1999-01-01

    Platinum group metal (PGM) may have toxic properties and their presence in the environment represent danger for human health. With the introduction of automobile catalytic converters containing PGM, the emission of these noble metals into atmosphere has increased. Platinum, palladium and rhodium are used in this catalytic converters to decrease toxic emissions of carbon monoxide, unburnt hydrocarbons and nitrogen oxides in vehicles exhaust gases. These catalysts are mobile sources of PGM into the environment. Thus, increased platinum concentrations have been found in various objects of environment because of the massive introduction of such catalytic converters are present. The preconcentration and separation of PGM and their determination by ICP-AES in environmental samples are described

  10. Qualitative and quantitative analysis of human nails to find correlation between nutrients and vitamin D deficiency using LIBS and ICP-AES.

    Science.gov (United States)

    Almessiere, M A; Altuwiriqi, R; Gondal, M A; AlDakheel, R K; Alotaibi, H F

    2018-08-01

    In this work, we analysed human fingernails of people who suffer from vitamin D deficiency using the laser-induced breakdown spectroscopy(LIBS) and inductively coupled plasma atomic emission spectroscopy (ICP-AES)techniques. The measurements have been conducted on 71 nail samples collected randomly from volunteers of different genders and ages ranged between 20 and 50 years. The main aim of this study is to find the correlation between vitamin D deficiency and the intensity of some dominated lines in the LIBS spectra. A LIBS spectrum consists of dominant lines of fifteen elements including calcium, magnesium, sodium, potassium, titanium, iron, chloride, sulphur, copper, chromium, zinc, nitrogen, phosphor, and oxygen. By recording the spectrum in specific ranges and focusing on calcium, magnesium, sodium, and potassium, we found a correlation between the intensity of the potassium (K) lines at (766.5 and 769.9 nm)and vitamin D level in both age groups (20 and 25 years old), with weak correlation for the calcium (Ca), magnesium (Mg), and sodium (Na) lines. To verify the validity of the LIBS results, we analysed the nail samples with ICP, a standard analytical technique. The elements detected with our LIBS technique are in a good agreement with those identified by ICP-AES. From the health and physiological perspectives, the LIBS system, which is used for spectral analysis in this work, is appropriate for diagnostic purposes such as to find the correlation between vitamin D deficiency and potassium content, especially for hypertensive patients who simultaneously take potassium-based medication and vitamin D supplement. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Barciela, Julia; Vilar, Manuela; Garcia-Martin, Sagrario [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Pena, Rosa M. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)], E-mail: qarosa@lugo.usc.es; Herrero, Carlos [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)], E-mail: cherrero@lugo.usc.es

    2008-10-17

    In this work several pre-treatment methods were studied for metal (Na, K, Mg, Cu and Ca) determination in Orujo spirit samples using inductively coupled plasma atomic emission spectrometry (ICP-AES). Dilution, digestion, evaporation, and cryogenic desolvatation techniques were comparatively evaluated. Because of their analytical characteristics, digestion and evaporation with nitrogen current were found to be appropriate procedures for the determination of metals in alcoholic spirit samples. Yet, if simplicity and application time are to be considered, the latter-evaporation in a water bath with a nitrogen current-stands out as the optimum procedure for any further determinations in Orujo samples by ICP-AES. Low detection levels and wide linear ranges (sufficient to determine these metals in the samples studied) were achieved for each metal. The recoveries (in the 97.5-100.5% range) and the precision (R.S.D. lower than 5.6%) obtained were also satisfactory. The selected procedure was applied to determine the content of metals in 80 representative Galician Orujo spirit samples with and without a Certified Brand of Origin (CBO) which had been produced using different distillation systems. The metal concentrations ranged between 0.37 and 79.7 mg L{sup -1} for Na,

  12. An inductively coupled plasma atomic emission spectrometric (ICP-AES) determination of boron and other trace impurities in aluminium metal

    International Nuclear Information System (INIS)

    Deshpande, S.S.; Patil, P.B.; Karanjikar, N.P.

    2002-01-01

    The optimisation and use of ICP-AES technique for the analysis of aluminium metal for B, Cr, Cu, Fe, Mg, Mn, Ni, Si, Ti, V and Zn in the concentration range 5.0 to 50.0 ppm is described. The method involves the dissolution of aluminium metal in acqua-regia. The matrix aluminium solution (2mg/ml) is mixed with composite impurity solution in proper proportions, for getting the required set of standards. JY 1 metre Czerny-Turner Scanning monochromator is used to measure peak intensities corresponding to each analyte wavelength selected. The mean relative standard deviation (RSD) of the method for various elements is found to be 4.0% -2.0% in the concentration range studied. (author)

  13. Chemical characterization of airborne particulate matter in ambient air of Nagoya, Japan, as studied by the multielement determination with ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Fukai, Taku; Kobayashi, Tatsuya; Sakaguchi, Masahiro; Aoki, Masanori; Saito, Tsuyoshi; Fujimori, Eiji; Haraguchi, Hiroki

    2007-01-01

    The multielement determination of PM 10 (airborne particulate matter smaller than 10 μm) samples, which was collected by a high volume air sampler at the urban site of Nagoya City, was carried out by inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The present analytical method was validated by analyzing urban particulate matter standard reference material of NIST SRM 1648. The analytical data for ca. 30 elements in PM 10 samples collected during a period from 8 September to 9 October, 2003, were obtained in the concentration range from sub-μg g -1 to several-10 mg g -1 , but the data for 18 elements among ca. 30 elements were available for the characterization of PM 10 samples in ambient air, because of problems caused by the filter blanks. Then, the trends concerning the distributions of diverse elements in PM 10 samples were analyzed based on the enrichment factors and size distribution factors. The lithophile and siderophile elements were distributed more than 50% in coarse particle fraction (>2.1 μm), which was derived mainly from natural sources, such as soils and crustal minerals. On the other hand, chalcophile elements were distributed more than 50% in fine particle fraction ( 10 samples as well as their mining influence factors (MIFs) suggested their wide use in industrial productions. (author)

  14. Comparison of MP AES and ICP-MS for analysis of principal and selected trace elements in nitric acid digests of sunflower (Helianthus annuus).

    Science.gov (United States)

    Karlsson, Stefan; Sjöberg, Viktor; Ogar, Anna

    2015-04-01

    The use of nitrogen as plasma gas for microwave plasma atomic emission spectroscopy (MP AES) is an interesting development in analytical science since the running cost can be significantly reduced in comparison to the inductively coupled argon plasma. Here, we evaluate the performance of the Agilent 4100 MP AES instrument for the analysis of principal metals (Ca, K, Mg, and Na), lithogenic metals (Al, Fe, and Mn) and selected trace metals (As, Ba, Cd, Co, Cr, Cu, Mo, Ni, Pb, V, and Zn) in nitric acid plant digests. The digests were prepared by microwave-assisted dissolution of dry plant material from sunflower (Helianthus annuus) in concentrated nitric acid. Comparisons are made with analysis of the same solutions with ICP-MS (Agilent 7500cx) using the octopole reaction system (ORS) in the collision mode for As, Fe, and V. The limits of detection were usually in the low µg L(-1) range and all principal and lithogenic metals were successfully determined with the MP AES and provided almost identical results with the ICP-MS. The same applies for the selected trace metals except for As, Co and Mo where the concentrations were below the detection limit with the MP AES. For successful analysis we recommend that (i) only atom lines are used, (ii) ionization is minimized (e.g. addition of CsNO3) and (iii) the use of internal standards should be considered to resolve spectral interferences. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Determination of some inorganic metals in edible vegetable oils by inductively coupled plasma atomic emission spectroscopy (ICP-AES

    Directory of Open Access Journals (Sweden)

    Musa Özcan, M.

    2008-09-01

    Full Text Available Seventeen edible vegetable oils were analyzed spectrometrically for their metal (Cu, Fe, Mn, Co, Cr, Pb, Cd, Ni, and Zn contents. Toxic metals in edible vegetable oils were determined by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES. The highest metal concentrations were measured as 0.0850, 0.0352, 0.0220, 0.0040, 0.0010, 0.0074, 0.0045, 0.0254 and 0.2870 mg/kg for copper in almond oil, for iron in corn oil-(c, for manganese in soybean oil, for cobalt in sunflower oil-(b and almond oil, for chromium in almond oil, for lead in virgin olive oil, for cadmium in sunflower oil-(e, for nickel almond oil and for zinc in almond oil respectively. The method for determining toxic metals in edible vegetable oils by using ICP-AES is discussed. The metals were extracted from low quantities of oil (2-3 g with a 10% nitric acid solution. The extracted metal in acid solution can be injected into the ICPAES. The proposed method is simple and allows the metals to be determined in edible vegetable oils with a precision estimated below 10% relative standard deviation (RSD for Cu, 5% for Fe, 15% for Mn, 8% for Co, 10% for Cr, 20% for Pb, 5% for Cd, 16% for Ni and 11% for Zn.En este estudio se analizó espectrométricamente el contenido en metales (Cu, Fe, Mn, Co, Cr, Pb, Cd, Ni, and Zn de 17 aceites vegetales comestibles mediante ICP-AES. Las concentaciones más elevadas se encontraron para el cobre en el aceite de almendra (0.0850 mg/kg, para el hierro en el aceite de maiz(c,(0.0352 mg/kg, para el manganeso en el aceite de soja (0.0220 mg/kg, para el cobalto en el aceite de girasol (b (0.0040 mg/kg, para el cromo en el aceite de almendra (0.0010 mg/kg, para el plomo en el aceite de oliva virgen (0.0074 mg/kg, para el cadmio en el aceite de girasol (e (0.0045 mg/kg, para el niquel en el aceite de almendra (0.0254 mg/kg y para el zincen el aceite de almendra (0.2870 mg/kg. Los metales se extrajeron a partir de bajas cantidades de aceite (2-3 g, con

  16. Determination of trace elements in seawater by air-flow injection/ICP-MS with chelating resin preconcentration

    International Nuclear Information System (INIS)

    Lee, Kyue-Hyung; Ohshima, Mitsuko; Motomizu, Shoji

    2002-01-01

    Multielement determination of major to trace metals in a deep seawater malt was accomplished by inductively coupled plasma-mass spectrometry (ICP-MS) together with inductively coupled plasma-atomic emission spectrometry (ICP-AES). Major elements, such as Na, K, Mg, and Ca, were measured by ICP-AES and normal continuos nebulization ICP-MS after sample dilution by 10 3 -10 6 fold. Fifteen trace elements in the concentrated metal solutions pretreated with cation-exchange resin or chelating resin could be simultaneously determined by air-flow injection/ICP-mass spectrometry (AFI/ICP-MS). Since the injection volume for AFI/ICP-MS was 25 μl, final samples volumes less than 500 μl were enough for several replicate measurements. Three different preconcentration methods assisted with AFI/ICP-MS were examined and could be successfully applied to a deep seawater malt. The analytical results of rate earth elements (REEs) and Co, Ni, Cu, Zn, Cd, and Pb obtained by AFI/ICP-MS coupled with disk filtration method using iminodiacetate (IDA)-type chelating resin were favorably agreed with the data obtained by AFI/ICP-MS coupled with column preconcentration method using chitosan-based chelating resin. (author)

  17. Determination of Al of Sucralfate in Stomachs by ICP-AES%ICP-AES测定大鼠胃内硫糖铝中的铝

    Institute of Scientific and Technical Information of China (English)

    李艳; 朱照静

    2009-01-01

    采用干法灰化,电感耦合等离子体-原子发射光谱法(ICP-AES)测定正常大鼠胃内硫糖铝中的铝量.结果表明,最佳分析波长为396.153nm,检出限为8ng·mL-1,各组内相对标准偏差均小于0.81%,组间相对标准偏差均小于13.4%,铝的回收率在96.0%-99.5%之间,表明ICP-AES测定大鼠胃内硫糖铝中铝的精密度、准确度良好,满足生物样品分析要求.大鼠灌服硫糖铝6h后胃内的铝基本排空,与正常胃排空时间一致,表明硫糖铝中的铝对正常胃粘膜无枯附作用.

  18. Multielement determination of major-to-ultratrace elements in plant reference materials by ICP-AES/ICP-MS and evaluation of their enrichment factors

    International Nuclear Information System (INIS)

    Hokura, Akiko; Matsuura, Hirotaka; Katsuki, Fumie; Haraguchi, Hiroki

    2000-01-01

    The multielement determination of major-to-ultratrace elements in plant reference materials (SRM Pine Needles, SRM Tomato Leaves, and NIES Tea Leaves) was carried out by ICP-AES (inductively coupled plasma atomic emission spectrometry) and ICP-MS (inductively coupled plasma mass spectrometry). The plant sample was decomposed with nitric acid and hydrofluoric acid in a Teflon beaker on a hot plate. The digest was dissolved in 1 M HNO 3 solution, and then subjected to elemental analyses. As a consequence, the analytical data for about 40 elements including rare earth elements (REEs) were obtained over a wide concentration range, for example, from 49600 μg g -1 of Ca to 6.2 ng g -1 of Lu in Tomato Leaves. The enrichment factors, which were estimated by normalizing the observed concentrations of analyte elements in plant reference materials to their soil abundances, were evaluated in order to discuss the relative abundances of various elements between plants and soil. It was found that most of the elements, except for REEs in Pine Needles and Tea Leaves, were significantly accumulated in the plant reference materials. In particular, the essential elements (K, Mg, Ca, Mn, Cu, Zn, B and P) for plant growth provided large enrichment factors. (author)

  19. Comparative study for essential elements determination in milk products samples by INAA and ICP-AES; Estudo comparativo na determinacao de elementos essenciais em amostras de produtos lacteos por AANI e ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Kira, Carmen S. [Instituto Adolfo Lutz, Sao Paulo, SP (Brazil). Secao de Equipamentos Especializados; Maihara, Vera A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Lab. de Analise por Ativacao Neutronica

    2002-07-01

    The mineral elements Ca, Fe, K, Mg, Na and Zn were analyzed in milk products by using instrumental neutron activation analysis (INAA) and inductively coupled plasma atomic emission spectrometry (ICP-AES). The study included four types of cheese (mozzarella, minas, prato, parmesan), chocolate milk and yogurt. The samples were purchased from the local markets. Average concentrations ranged from 3668 (chocolate milk) to 16558 (parmesan cheese) mg/kg for Ca; from 2.61 (parmesan cheese) to 28.9 (chocolate milk) mg/kg for Fe; from 673 (mozzarella cheese) to 10492 (chocolate milk) mg/kg for K; from 398 (yogurt) to 2280 (minas cheese) mg/kg for Mg; from 1681 (yogurt) to 15248 (parmesan cheese) mg/kg for Na; from 12.1 (chocolate milk) to 71.8 (parmesan cheese) mg/kg for Zn. Two National Institute of Standards and Technology (NIST) standard reference materials (SRM 8435 Whole Milk Powder and SRM 1549 Non Fat Milk Powder) were analyzed to verify method accuracy. The statistic test used to determine the significance of the difference between the techniques was based on Unpaired t-Student test. Statistical test revealed no significance differences (P< 0,05) between the average values provided by the two methods for the most of determined elements. (author)

  20. PIXE and ICP-AES analysis of early glass unearthed from Xinjiang (China)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, B. [Department of Technical Physics, School of Physics, Peking University, Beijing 100871 (China); Cheng, H.S. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China)]. E-mail: hscheng@fudan.edu.cn; Ma, B. [School of Information Science and Engineering, Fudan University, Shanghai 200433 (China); Li, Q.H. [Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Zhang, P. [Xinjiang Institute of Archaeology, Urumchi 830011 (China); Gan, F.X. [School of Information Science and Engineering, Fudan University, Shanghai 200433 (China); Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Yang, F.J. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China)

    2005-10-15

    Early glasses (about 1066 BC-220 AD) unearthed from Xinjiang of China were chemically characterized by using PIXE and ICP-AES. It was found that these glasses were basically attributed to PbO-BaO-SiO{sub 2} system, K{sub 2}O-SiO{sub 2} system, Na{sub 2}O-CaO-SiO{sub 2} system and Na{sub 2}O-CaO-PbO-SiO{sub 2} system. The results from the cluster analysis showed that some glasses had basically similar recipe and technology. The PbO-BaO-SiO{sub 2} glass and the K{sub 2}O-SiO{sub 2} glass were thought to come from the central area and the south of ancient China, respectively. The part of the Na{sub 2}O-CaO-SiO{sub 2} glass (including the Na{sub 2}O-CaO-PbO-SiO{sub 2} glass) might be imported from Mesopotamia, while the other part might be locally produced.

  1. Construcción y caracterización de un nuevo nebulizador múltiple para técnicas analíticas basadas en plasma (ICP-OES, ICP-MS y MP-AES).

    OpenAIRE

    Lúñez Fernández, Claudia

    2016-01-01

    En la siguiente memoria, se presenta la metodología para la construcción de un nuevo nebulizador múltiple, resultado de una serie de nebulizadores anteriores, los cuales se han ido mejorando para optimizar las características del aerosol generado y con ello los parámetros analíticos de calidad en la espectrometría de emisión atómica con plasma de microondas (MP-AES) y espectrometría de emisión óptica con plasma de acoplamiento inductivo (ICP-OES). Este nuevo nebulizador multiconducto presenta...

  2. Preconcentration and Determination of Copper and Zinc in Natural Water Samples by ICP-AES After Complexation and Sorption on Amberlite XAD-2

    Directory of Open Access Journals (Sweden)

    Ferreira Sérgio Luis Costa

    1998-01-01

    Full Text Available The present paper describes a procedure for separation, preconcentration and sequential determination of trace amounts of copper and zinc in natural water samples, by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES. The proposed method is based on the complexation of copper(II and zinc(II ions by 1-(2-thiazolylazo-2-naphthol (TAN and sorption on to Amberlite XAD-2 resin. Parameters such as: TAN amount, pH effect on the complexation and sorption of TAN complexes, agitation time for complete sorption, concentration of metal ion, mass of Amberlite XAD-2, desorption of metal ions from XAD-2 resin and sample volume were studied. The results demonstrated that the copper(II and zinc(II ions, in the range of 0.10 to 100.00 mug, contained in a solution sample volume of 400 mL, in the pH range of 5.7 to 8.3, on the form of TAN complexes had been quantitatively retained on to XAD-2 resin. The shaking time required for sorption is 1 h using a resin mass of 1.4 g. The solution for determination of copper and zinc by ICP-AES is obtained, after desorption of the ions from the XAD-2 resin, using 5 mL of 2 mol L-1 hydrochloric acid and shaking the system for 5 min. The procedure was applied to the determination of copper and zinc in several natural water samples. The standard addition technique was applied and the obtained recoveries revealed that the proposed procedure has a good accuracy. A high enrichment factor (80 and simplicity are the main advantages in this analytical protocol.

  3. Comparative study for essential elements determination in milk products samples by INAA and ICP-AES

    International Nuclear Information System (INIS)

    Kira, Carmen S.; Maihara, Vera A.

    2002-01-01

    The mineral elements Ca, Fe, K, Mg, Na and Zn were analyzed in milk products by using instrumental neutron activation analysis (INAA) and inductively coupled plasma atomic emission spectrometry (ICP-AES). The study included four types of cheese (mozzarella, minas, prato, parmesan), chocolate milk and yogurt. The samples were purchased from the local markets. Average concentrations ranged from 3668 (chocolate milk) to 16558 (parmesan cheese) mg/kg for Ca; from 2.61 (parmesan cheese) to 28.9 (chocolate milk) mg/kg for Fe; from 673 (mozzarella cheese) to 10492 (chocolate milk) mg/kg for K; from 398 (yogurt) to 2280 (minas cheese) mg/kg for Mg; from 1681 (yogurt) to 15248 (parmesan cheese) mg/kg for Na; from 12.1 (chocolate milk) to 71.8 (parmesan cheese) mg/kg for Zn. Two National Institute of Standards and Technology (NIST) standard reference materials (SRM 8435 Whole Milk Powder and SRM 1549 Non Fat Milk Powder) were analyzed to verify method accuracy. The statistic test used to determine the significance of the difference between the techniques was based on Unpaired t-Student test. Statistical test revealed no significance differences (P< 0,05) between the average values provided by the two methods for the most of determined elements. (author)

  4. Chemical yield determination for 59Ni, 63Ni and 56Fe in low and intermediate nuclear wastes by ICP-AES

    International Nuclear Information System (INIS)

    Franco, Milton B.; Santos Neto, Francisco C. dos; Reis Junior, Aluisio S.; Temba, Eliane S.C.; Monteiro, Roberto P.G.

    2011-01-01

    Iron and nickel are constituents of a wide range of metallic materials used in nuclear reactor construction and their corresponding activation products are often encountered in reactor-derived solid low and intermediate-level wastes. The most significant radioisotopes of iron and nickel, in terms of quantity and half life, are 55 Fe (t 1/2 =2.73y), 59 Ni (t 1/2 =7.6x10 4 y) and 63 Ni (t 1/2 =10 2 y) and they are activation products of stable iron and nickel. 59 Ni is an X-ray - emitting and 55 Fe and 63 Ni are β-particle-emitting radionuclides and so they are radionuclides of interest for the performance of assessment studies of waste storage or disposal. For their determination in the radioactive wastes is necessary to know the chemical yield for the radiochemical separation procedures prior analytical measurements. In this work Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) technique was used for this aim. Total nickel and iron in waste samples from nuclear power plants were determined before and after the radiochemical separation at specific wavelengths, 231.604 nm and 259.940 nm respectively. The chemical yields for nickel and iron recovery were around 82 % for iron and 59 % for nickel according the analytical methodology adopted. (author)

  5. Geographical traceability of wild Boletus edulis based on data fusion of FT-MIR and ICP-AES coupled with data mining methods (SVM)

    Science.gov (United States)

    Li, Yun; Zhang, Ji; Li, Tao; Liu, Honggao; Li, Jieqing; Wang, Yuanzhong

    2017-04-01

    In this work, the data fusion strategy of Fourier transform mid infrared (FT-MIR) spectroscopy and inductively coupled plasma-atomic emission spectrometry (ICP-AES) was used in combination with Support Vector Machine (SVM) to determine the geographic origin of Boletus edulis collected from nine regions of Yunnan Province in China. Firstly, competitive adaptive reweighted sampling (CARS) was used for selecting an optimal combination of key wavenumbers of second derivative FT-MIR spectra, and thirteen elements were sorted with variable importance in projection (VIP) scores. Secondly, thirteen subsets of multi-elements with the best VIP score were generated and each subset was used to fuse with FT-MIR. Finally, the classification models were established by SVM, and the combination of parameter C and γ (gamma) of SVM models was calculated by the approaches of grid search (GS) and genetic algorithm (GA). The results showed that both GS-SVM and GA-SVM models achieved good performances based on the #9 subset and the prediction accuracy in calibration and validation sets of the two models were 81.40% and 90.91%, correspondingly. In conclusion, it indicated that the data fusion strategy of FT-MIR and ICP-AES coupled with the algorithm of SVM can be used as a reliable tool for accurate identification of B. edulis, and it can provide a useful way of thinking for the quality control of edible mushrooms.

  6. [Analysis of inorganic elements in hydroponic Taraxacum mongolicum grown under different spectrum combinations by ICP-AES].

    Science.gov (United States)

    Chen, Xiao-li; Morewane, M B; Xue, Xu-zhang; Guo, Wen-zhong; Wang, Li-chun

    2015-02-01

    Dandelion (Taraxacum mongolicum) was hydroponically cultured in a completely enclosed plant factory, in which fluorescence and LED emitting spectra of different bands were used as the sole light source for plant growth. Effects of spectral component on the growth of dandelion were studied and the contents of ten inorganic elements such as K, P, Ca, Mg, Na, Fe, Mn, Zn, Cu and B in dandelion were analyzed by ICP-AES technology. The results showed that: (1) Under the condition of similar photosynthetic active radiation (PAR), single R or combined spectrums of FLRB were beneficial for biomass accumulation, while single B was the contrary; (2) Macroelements content ratio in Taraxacum mongolicum grown under FLwas K:Ca:P:Mg : Na=79.74:32.39:24.32:10.55:1.00, microelements content ratio was Fe:Mn:B:Zn:Cu = 9.28:9.71:3.82:2.08:1.00; (3) Red light (peak at 660 nm) could promote the absorptions of Ca, Fe, Mn, Zn, while absorption of Cu was not closely related to spectral conditions; (4) Thehighest accumulation of Ca, Na, Mn and Zn were obtained in aerial parts of Taraxacum mongolicum plants grown under pure red spectrum R, while the accumulation of the rest six elements reached the highest level under the mixed spectrum FLRB.

  7. A rapid sample decomposition procedure for bromo-heavies containing ferruginous material: determination of REEs and thorium by ICP-AES

    International Nuclear Information System (INIS)

    Khorge, C.R.; Murugesan, P.; Chakrapani, G.

    2013-01-01

    A rapid method of sample decomposition and dissolution for bromoform heavies is described for the determination of REEs and thorium by inductively coupled plasma- optical emission spectrometry. For application to geochemical exploration to achieve the high sample throughput; a simple and rapid analytical procedure is a prerequisite. In order to speed-up the existing methodology, phosphate fusion was introduced for decomposition of samples. In the proposed method, bromoform-heavies material are fused with 1:1 mixture of sodium dihydrogen orthophosphate and tetra-sodium pyrophosphate and dissolved in distilled water. After disintegration of melt, the solution was subjected to oxalate precipitation followed by R 2 O 3 separation for separating the REEs from major matrix interfering elements. The rare earth elements and thorium in the resultant solution were determined by ICP-OES. The results are compared with the results obtained by well-established existing dissolution procedures involving HF-HCl-HClO 4 acid treatment and NaF/KHF 2 fusion followed by H 2 SO 4 acid fuming. The accuracy of the method was evaluated by doping the phosphate blank with known amount of REEs and comparing the recoveries obtained using the present method. The method is simple, rapid and is suitable for the routine determination of REEs and Th in bromoform-heavies. The RSD of the method was found to be within 1-3% for Th and REEs by ICP-AES. (author)

  8. ICP-AES Determination of Mineral Content in Boletus tomentipes Collected from Different Sites of China.

    Science.gov (United States)

    Wang, Xue-mei; Zhang, Ji; Li, Tao; Li, Jie-qing; Wang, Yuan-zhong; Liu, Hong-gao

    2015-05-01

    P, Na, Ca, Cu, Fe, Mg, Zn, As, Cd, Co, Cr and Ni, contents have been examined in caps and stipes of Boletus tomentipes collected from different sites of Yunnan province, southwest China. The elements were determined using inductively coupled plasma atomic emission spectroscopy (ICP-AES) with microwave digestion. P, Ca, Mg, Fe, Zn and Cu were the most abundant amongst elements determined in Boletus tomentipes. The caps were richer in P, Mg, Zn and Cd, and the stipes in Ca, Co and Ni. Cluster analysis showed a difference between Puer (BT7 and BT8) and other places. The PCA explained about 77% of the total variance, and the minerals differentiating these places were P (PC1) together with Ca, Cu, Fe, Mg, As and Ni, Na (PC2) together with Cd, and Zn (PC3). The results of this study imply that element concentrations of a mushroom are mutative when collected from the different bedrock soil geochemistry.

  9. Geographical traceability of wild Boletus edulis based on data fusion of FT-MIR and ICP-AES coupled with data mining methods (SVM).

    Science.gov (United States)

    Li, Yun; Zhang, Ji; Li, Tao; Liu, Honggao; Li, Jieqing; Wang, Yuanzhong

    2017-04-15

    In this work, the data fusion strategy of Fourier transform mid infrared (FT-MIR) spectroscopy and inductively coupled plasma-atomic emission spectrometry (ICP-AES) was used in combination with Support Vector Machine (SVM) to determine the geographic origin of Boletus edulis collected from nine regions of Yunnan Province in China. Firstly, competitive adaptive reweighted sampling (CARS) was used for selecting an optimal combination of key wavenumbers of second derivative FT-MIR spectra, and thirteen elements were sorted with variable importance in projection (VIP) scores. Secondly, thirteen subsets of multi-elements with the best VIP score were generated and each subset was used to fuse with FT-MIR. Finally, the classification models were established by SVM, and the combination of parameter C and γ (gamma) of SVM models was calculated by the approaches of grid search (GS) and genetic algorithm (GA). The results showed that both GS-SVM and GA-SVM models achieved good performances based on the #9 subset and the prediction accuracy in calibration and validation sets of the two models were 81.40% and 90.91%, correspondingly. In conclusion, it indicated that the data fusion strategy of FT-MIR and ICP-AES coupled with the algorithm of SVM can be used as a reliable tool for accurate identification of B. edulis, and it can provide a useful way of thinking for the quality control of edible mushrooms. Copyright © 2017. Published by Elsevier B.V.

  10. Precise and accurate isotope ratio measurements by ICP-MS.

    Science.gov (United States)

    Becker, J S; Dietze, H J

    2000-09-01

    The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.

  11. ICP-AES method for metals in air. Pt 2 - analysis; final report on project R48113

    International Nuclear Information System (INIS)

    Taylor, C.; Howe, A.

    2002-04-01

    An ICP-AES instrument operating procedure has been drafted and incorporated in ISO 15202-3 Workplace air - Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry: Part 3 - Analysis. It is expected that this International Standard will be published during 2003. The performance of the analytical method described ISO 15202-3 was evaluated by carrying out laboratory experiments to determine analytical precision. The uncertainty associated with analytical variability was then combined with other sources of uncertainty arising from the sampling method described in ISO 15202-1. A first draft of a proposed new MDHS on Metals and metalloids in workplace air by Inductively Coupled Plasma Atomic Emission Spectrometry has been prepared based on ISO 15202-1, ISO 15202-2 and ISO 15202-3. It is expected that this will be published in late 2002 or early 2003

  12. ICP-AES determination of rare earth elements in coal fly ash samples of thermal power stations: assessment of possible recovery and environmental impact of rare earth elements

    International Nuclear Information System (INIS)

    Premadas, A.; Mary, Thomas Anitha; Chakrapani, G.

    2013-01-01

    Accurate determination of rare earth elements (REEs) in ashes of thermal power plants is important in the current scenario due to its economic value, and the pollution caused if they are released in to the environment. Their toxicity to living organisms now gaining importance in international community, and some investigation shows it causes retardation in plant growth. In coal based thermal stations huge quantity of coal used annually as a fuel and lakhs of tones of waste is generated in the form of ashes. Therefore studies were carried out on three aspects - fairly rapid and accurate ICP-AES determination REEs in coal fly ash samples using addition technique, a preliminary acid leaching studies on coal received from three different fired thermal power stations using hydrochloric acid at pH 1 and 2, and quantify the REEs leached, and economic recovery of REEs using di-(2-ethylhexyl) phosphoric acid solvent extraction process or precipitation hydroxides using dilute ammonia solution. The standard addition method of REEs determination using rate and reproducible values, besides the analysis is fast compared to the ion exchange separation of REEs followed by the ICP-AES determination. (author)

  13. The cause of high-intensity long-duration continuous AE activity (HILDCAAS): interplanetary Alfven wave trains

    International Nuclear Information System (INIS)

    Tsurutani, B.T.; Gonzalez, W.D.

    1987-01-01

    It is shown that high intensity (AE > 1,000 nT), long duration (T > 2 d) continuous auroral activity (HILDCAA) events are caused by outward (from the sun) propagating interplanetary Alfven wave trains. The Alfven waves are often (but not always) detected several days after major interplanetary events, such as shocks and solar wind density enhancements. Presumably magnetic reconnection between the southward components of the Alfven wave magnetic fields and magnetospheric fields is the mechanism for transfer of solar wind energy to the magnetosphere. If the stringent requirements for HILDCAA events are relaxed, there are many more AE events of this type. A brief inspection indicates that these are also related to interplanetary Alfvenic fluctuations. We therefore suggest that most auroral activity may be caused by reconnection associated with Alfven waves in the interplanetary medium. (author)

  14. The influence of room temperature on Mg isotope measurements by MC-ICP-MS.

    Science.gov (United States)

    Zhang, Xing-Chao; Zhang, An-Yu; Zhang, Zhao-Feng; Huang, Fang; Yu, Hui-Min

    2018-03-24

    We observed that the accuracy and precision of magnesium (Mg) isotope analyses could be affected if the room temperature oscillated during measurements. To achieve high quality Mg isotopic data, it is critical to evaluate how the unstable room temperature affects Mg isotope measurements by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). We measured the Mg isotopes for the reference material DSM-3 using MC-ICP-MS under oscillating room temperatures in spring. For a comparison, we also measured the Mg isotopes under stable room temperatures, which was achieved by the installation of an improved temperature control system in the laboratory. The δ 26 Mg values measured under oscillating room temperatures have a larger deviation (δ 26 Mg from -0.09 to 0.08‰, with average δ 26 Mg = 0.00 ± 0.08 ‰) than those measured under a stable room temperature (δ 26 Mg from -0.03 to 0.03‰, with average δ 26 Mg = 0.00 ± 0.02 ‰) using the same MC-ICP-MS system. The room temperature variation can influence the stability of MC-ICP-MS. Therefore, it is critical to keep the room temperature stable to acquire high precise and accurate isotopic data when using MC-ICP-MS, especially when using the sample-standard bracketing (SSB) correction method. This article is protected by copyright. All rights reserved.

  15. New approach of a transient ICP-MS measurement method for samples with high salinity.

    Science.gov (United States)

    Hein, Christina; Sander, Jonas Michael; Kautenburger, Ralf

    2017-03-01

    In the near future it is necessary to establish a disposal for high level nuclear waste (HLW) in deep and stable geological formations. In Germany typical host rocks are salt or claystone. Suitable clay formations exist in the south and in the north of Germany. The geochemical conditions of these clay formations show a strong difference. In the northern ionic strengths of the pore water up to 5M are observed. The determination of parameters like K d values during sorption experiments of metal ions like uranium or europium as homologues for trivalent actinides onto clay stones are very important for long term safety analysis. The measurement of the low concentrated, not sorbed analytes commonly takes place by inductively coupled plasma mass spectrometry (ICP-MS). A direct measurement of high saline samples like seawater with more than 1% total dissolved salt content is not possible. Alternatives like sample clean up, preconcentration or strong dilution have more disadvantages than advantages for example more preparation steps or additional and expensive components. With a small modification of the ICP-MS sample introduction system and a home-made reprogramming of the autosampler a transient analysing method was developed which is suitable for measuring metal ions like europium and uranium in high saline sample matrices up to 5M (NaCl). Comparisons at low ionic strength between the default and the transient measurement show the latter performs similarly well to the default measurement. Additionally no time consuming sample clean-up or expensive online dilution or matrix removal systems are necessary and the analysation shows a high sensitivity due to the data processing based on the peak area. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. High-intensity, long-duration, continuous AE activity events associated with Alfvénic fluctuations in 2003

    Science.gov (United States)

    Prestes, Alan; Klausner, Virginia; Ojeda-González, Arian

    2017-11-01

    The interaction between a fast-speed and a low-speed stream causes large-amplitude Alfvénic fluctuations; consequently, the intermittency and the brief intervals of southward magnetic field associated with Alfvén waves may cause high levels of AE activity, the so-called high-intensity, long-duration, continuous AE activity (HILDCAA). In this article, the 4 h windowed Pearson cross-correlation (4WPCC) between the solar wind velocity and the interplanetary magnetic field (IMF) components is performed in order to confirm that the less strict HILDCAA (HILDCAAs*) events include a larger number of Alfvén waves than the HILDCAA events, once HILDCAAs disregard part of the phenomenon. Actually, a HILDCAA event is entirely contained within a HILDCAA* event. However, the opposite is not necessarily true. This article provides a new insight, since the increase of Alfvén waves results in an increase of auroral electrojet activity; consequently, it can cause HILDCAAs* events. Another important aspect of this article is that the superposed epoch analysis (SEA) results reaffirm that the HILDCAAs* are associated with high-speed solar streams (HSSs), and also the HILDCAAs* present the same physical characteristics of the traditional HILDCAA events.

  17. Analysis of the characteristics of AE wave using boring core of sedimentary soft rock and study on the field measurement of AE for the evaluation of EDZ (Joint research)

    International Nuclear Information System (INIS)

    Aoki, Kenji; Mito, Yoshitada; Minami, Masayuki; Matsui, Hiroya; Niunoya, Sumio

    2007-09-01

    To understand the size and state of EDZ accurately is one of the key issues in the technological development for geological disposal of High-Level Radioactive Waste. As one of these evaluation technologies, AE which is measured directly and evaluates EDZ is paid to attention inside and outside the country, and the utility is reported for the crystalline rock. However, there are few cases to apply AE in sedimentary soft rocks to EDZ evaluation because of the difficulty to measure a few AE waves with small energy. In this study, the authors made a series of laboratory tests including tri-axial test using the stiff and servo-controlled testing machine in order to clarify the possibility to measure AE waves in Neogene siliceous rocks in Horonobe, Hokkaido, Japan (2005). The authors conducted the high stiffness tri-axial compression tests with AE measurements. And, the authors extracted an effective AE parameter to the evaluation of EDZ in the neogene (2005). The authors evaluated the mechanism of EDZ, which assumed from the result in occurrence of crack in the rock by measurement system and DEM analysis, by using the effective parameter (2006). In the EDZ examination which is planned since the second stage, the authors constructed a concept of the necessary measurement and evaluation system (2007). (author)

  18. High-Precision Measurement of Eu/Eu* in Geological Glasses via LA-ICP-MS Analysis

    Science.gov (United States)

    Tang, Ming; McDonough, William F.; Arevalo, Ricardo, Jr.

    2014-01-01

    Elemental fractionation during laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) analysis has been historically documented between refractory and volatile elements. In this work, however, we observed fractionation between light rare earth elements (LREEs) and heavy rare earth elements (HREEs) when using ablation strategies involving large spot sizes (greater than 100 millimeters) and line scanning mode. In addition: (1) ion yields decrease when using spot sizes above 100 millimeters; (2) (Eu/Eu*)(sub raw) (i.e. Europium anomaly) positively correlates with carrier gas (He) flow rate, which provides control over the particle size distribution of the aerosol reaching the ICP; (3) (Eu/Eu*)(sub raw) shows a positive correlation with spot size, and (4) the changes in REE signal intensity, induced by the He flow rate change, roughly correlate with REE condensation temperatures. The REE fractionation is likely driven by the slight but significant difference in their condensation temperatures. Large particles may not be completely dissociated in the ICP and result in preferential evaporation of the less refractory LREEs and thus non-stoichiometric particle-ion conversion. This mechanism may also be responsible for Sm-Eu-Gd fractionation as Eu is less refractory than Sm and Gd. The extent of fractionation depends upon the particle size distribution of the aerosol, which in turn is influenced by the laser parameters and matrix. Ablation pits and lines defined by low aspect ratios produce a higher proportion of large particles than high aspect ratio ablation, as confirmed by measurements of particle size distribution in the laser induced aerosol. Therefore, low aspect ratio ablation introduces particles that cannot be decomposed and/or atomized by the ICP and thus results in exacerbated elemental fractionation. Accurate quantification of REE concentrations and Eu/Eu* requires reduction of large particle production during laser ablation. For the reference

  19. Measurement of inclusion size by laser ablation ICP mass spectrometry

    International Nuclear Information System (INIS)

    Karasev, Andrey V.; Suito, Hideaki

    2004-01-01

    By using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), the measurement of particle size has been made for one component oxide (Al 2 O 3 and MgO) and multicomponent oxide (12CaO·7Al 2 O 3 and CaO-Al 2 O 3 -MgO) located on surface of iron or glass sample. The method of particle size estimation by LA-ICP-MS has been developed coupled with a new method of making samples with particles. The size calibration lines for Al 2 O 3 , MgO and CaO particles have been obtained. The results of particle size measurement by LA-ICP-MS are compared with those by SEM and single-particle optical sensing (SPOS) methods. It was confirmed that LA-ICP-MS has the perspective to be used for the quick measurement of inclusion composition and size in metal and other materials. The size frequency distributions of Al 2 O 3 particles measured by LA-ICP-MS in iron samples with particles agree reasonably well with those by SEM and SPOS in the range of particle diameter from 2 to 20 μm. The size of Al 2 O 3 , MgO and complex oxide (12CaO·7Al 2 O 3 and CaO-Al 2 O 3 -MgO) particles measured by LA-ICP-MS is in good agreement with that by SEM in the range of particle diameter from 10 to 40 μm. (author)

  20. Determination of trace metals in TSP and PM2.5 materials collected in the Metropolitan Area of Monterrey, Mexico: A characterization study by XPS, ICP-AES and SEM-EDS

    Science.gov (United States)

    González, Lucy T.; Longoria Rodríguez, F. E.; Sánchez-Domínguez, M.; Cavazos, Aleyda; Leyva-Porras, C.; Silva-Vidaurri, L. G.; Askar, Karim Acuña; Kharissov, B. I.; Villarreal Chiu, J. F.; Alfaro Barbosa, J. M.

    2017-11-01

    The concentration levels of trace metals of toxicological importance were evaluated in the total suspended particles (TSP) and particulate matter smaller than 2.5 μm (PM2.5) collected in the Metropolitan Area of Monterrey (MAM) in Mexico. Samples were characterized by inductively coupled plasma atomic emission spectroscopy (ICP-AES), X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy with an energy-dispersive spectroscopy system (SEM-EDS). In addition, the data were statistically treated by the methodology of Pearson Correlation (PC) and Principal Components Analysis (PCA) to identify the possible emitting sources. Surface analysis of the particulate matter (PM) by XPS revealed that the most abundant elements were Ca, Al, Na, Zn, Cu and Mg. The deconvolution of the Ca2p, Zn2p and Cu2p signals showed that the main contributors were CaCO3, ZnO and Cu/Cu2O, respectively. The bulk analysis of the PM by ICP-AES showed Fe, Cu and Zn as the most abundant elements. Fe-rich particles presented two different morphologies: the prismatic particles were associated with a natural origin, while the spherical particles with anthropogenic sources. The Zn and Cu were predominantly observed in the sampling stations with high vehicular traffic, and the emitting sources were associated with the burning of fuels from automobiles and the wear of the tires and brakes. The highest concentration of Pb was detected in the sampling station located near the industrial zones, and its cause was associated with the ceramic and glass industries, the burning of fuel oil in power plants and the production of lead-based batteries for automobiles.

  1. Targeted adhesion for sucralfate to impaired gastric mucosa of SD rats by ICP-AES method%ICP-AES法考察硫糖铝对SD大鼠胃溃疡粘膜的靶向粘附

    Institute of Scientific and Technical Information of China (English)

    李艳; 林凤云; 罗立骏; 曾令高; 朱照静

    2016-01-01

    目的:建立硫糖铝中铝离子(Al3+)在大鼠胃组织残留量的测定方法,考察硫糖铝对胃溃疡粘膜的靶向粘附作用.方法:采用干法灰化消解胃组织样品,电感耦合等离子体-原子发射光谱法(ICP-AES)测定给药后不同时间点大鼠胃组织中Al3+的残留量.ICP-AES检测波长为396.153 nm,检测器为电感耦合阵列检测器,载气为氩气.结果:干法灰化大鼠胃溃疡组织,样品消解完全,可满足ICP-AES的检测要求;在选定的最佳条件下用ICP-AES检测Al3+的检出限为8 ng· mL-1,样品间Al3+残留量相对偏差小于13.4%,回收率在96.0%~99.5%之间;给药0.5~4 h时间段内,溃疡胃组织中的Al3+残留率为正常胃组织的2倍以上;给药6h后,正常胃组织中Al3+残留率显著下降,仅为0.84%,而溃疡胃组织在给药16 h后仍高达29%.结论:ICP-AES测定大鼠胃组织中Al3+的残留量准确可行;硫糖铝对胃溃疡粘膜的粘附性显著高于正常胃粘膜,具有良好的靶向性.

  2. Development, optimisation, and application of ICP-SFMS methods for the measurement of isotope ratios

    International Nuclear Information System (INIS)

    Stuerup, S.

    2000-07-01

    The measurement of isotopic composition and isotope ratios in biological and environmental samples requires sensitive, precise, and accurate analytical techniques. The analytical techniques used are traditionally based on mass spectrometry, among these techniques is the ICP-SFMS technique, which became commercially available in the mid 1990s. This technique is characterised by high sensitivity, low background, and the ability to separate analyte signals from spectral interferences. These features are beneficial for the measurement of isotope ratios and enable the measurement of isotope ratios of elements, which it has not previously been possible to measure due to either spectral interferences or poor sensitivity. The overall purpose of the project was to investigate the potential of the single detector ICP-SFMS technique for the measurement of isotope ratios in biological and environmental samples. One part of the work has focused on the fundamental aspects of the ICP-SFMS technique with special emphasize on the features important to the measurement of isotope ratios, while another part has focused on the development, optimisation and application of specific methods for the measurement of isotope ratios of elements of nutritional interest and radionuclides. The fundamental aspects of the ICP-SFMS technique were investigated theoretically and experimentally by the measurement of isotope ratios applying different experimental conditions. It was demonstrated that isotope ratios could be measured reliably using ICP-SFMS by educated choice of acquisition parameters, scanning mode, mass discrimination correction, and by eliminating the influence of detector dead time. Applying the knowledge gained through the fundamental study, ICP-SFMS methods for the measurement of isotope ratios of calcium, zinc, molybdenum and iron in human samples and a method for the measurement of plutonium isotope ratios and ultratrace levels of plutonium and neptunium in environmental samples

  3. The Activation of Non-evaporable Getters Monitored by AES, XPS, SSIMS and Secondary Electron Yield Measurements

    CERN Document Server

    Scheuerlein, C

    2002-01-01

    In this thesis the potential of the three classical surface analysis techniques Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS) and static secondary ion mass spectrometry (SSIMS) for the characterisation of non-evaporable getter (NEG) materials is assessed and artefacts are described. The various NEG samples have been analysed in the context of the development of NEG thin film coatings for use in accelerator ultra high vacuum (UHV) systems. The secondary electron yield (SEY), which is a functional surface property of great importance for the application of NEG to accelerators, has been measured. The maximum SEY of an air exposed TiZr and TiZrV coating can be reduced from above 2.0 to below 1.1 during a 2 h heat treatment at 250 and 200 °C, respectively. Saturating an activated TiZrV surface in UHV increases the maximum SEY by about 0.1. Thus, in UHV the SEY of an activated NEG coating does not exceed the threshold value of 1.35, above which multipacting is predicted to occur in th...

  4. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    Science.gov (United States)

    Tagami; Uchida; Hamilton; Robison

    2000-07-01

    Extraction techniques for recovery of technetium-99 (99Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (MI) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g(-1) dry weight (dw). The limit of detection for 99Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g(-1) dw under standard operating conditions.

  5. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.; Hamilton, T.; Robison, W.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g -1 dry weight (dw). The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g -1 dw under standard operating conditions

  6. A windows based automated quality control system for the ICP-AES analysis of Waste Isolation Pilot Plant (WIPP) brines

    International Nuclear Information System (INIS)

    Gerth, D.J.

    1996-01-01

    High sample volume analytical laboratories typically require automation of tasks to maximize efficiency and productivity. Typical approaches target instrument operation and data reporting (LIMS), but frequently ignore the data evaluation and run time QC aspects. Automation of these steps can save up to 50% of the time it takes to analyze, evaluate, and report data from a typical ICP-AES run. The program developed in this project addresses this need by performing a CLP-style evaluation of the run time QC data included in an instrument run. Written in Microcraft Visual Basic 3.0, it makes use of a Microsoft Access database to store method parameters and QC sample results for control charting. In operation, the analyst enters method background data (e.g., control samples types and acceptance criteria for each analyte), which is then stored in the method database. Once the method parameters are entered, instrument data files may be imported for review. Upon import, the run is automatically checked against desired QC criteria, QC sample data are added to the database, and failing samples flagged appropriately. Analytes passing all QC checks are flagged for upload to the laboratory LIMS. The analyst may then review the run sample by sample, and, if desired, override the computer upload flag. An exception report may be generated detailing samples that require reanalysis

  7. Application of ICP-MS in Environmental Sampling Analysis for Safeguards

    International Nuclear Information System (INIS)

    Eko Pudjadi; Petrus Zacharias; Budi Prayitno

    2004-01-01

    Environmental samples measured by ICP-MS were analyzed for safeguards. There are two isotopes in environmental sampling that is used to find out the origin of nuclear materials and verify undeclared nuclear activities. Uranium isotopes are 234 U, 235 U, 236 U and 238 U and Plutonium isotopes are 239 Pu, 240 Pu, 241 Pu and 242 Pu. Uranium isotopes are used to verify an existing of nuclear power plants, enrichment plants or reprocessing plants. Plutonium isotopes are used to clarify global fallout from nuclear weapon testing and accident of nuclear facility or military purposes. The high sensitivity of ICP-MS can detect the isotopic fingerprint and trace elements in ppb concentration; ICP-MS has been applied to measure 235 U isotopic ratio and 240 Pu/ 239 Pu isotopic ratios. The sensitivity of ICP-MS is high precision and low operational cost in environmental sampling and can be considered in nuclear power design based on safeguards for development countries. (author)

  8. Measurement of isotopic composition of lanthanides in reprocessing process solutions by high-performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC/ICP-MS)

    International Nuclear Information System (INIS)

    Okano, Masanori; Jitsukata, Shu; Kuno, Takehiko; Yamada, Keiji

    2011-01-01

    Isotopic compositions of fission products in process solutions and wastes in a reprocessing plant are valuable to proceed safety study of the solutions and research/development concerning treatment/disposal of the wastes. The amount of neodymium-148 is a reliable indication to evaluate irradiation history. The isotopic compositions of samarium and gadolinium in high radioactive wastes are referred to as essential data to evaluate environmental impact in geological repositories. However, pretreatment of analysis must be done with complicated chemical separation such as solvent extraction and ion exchange. The actual measurement data of isotopic compositions of lanthanides comparable to the one of actinides in spent fuel reprocessing process has not been obtained enough. Rapid and high sensitive analytical technique based on high-performance liquid chromatography (HPLC) with an inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the measurement of isotopic compositions of lanthanides in spent fuel reprocessing solutions. HPLC/ICP-MS measurement system was customized for a glove-box to be applied to the radioactive solutions. The cation exchange chromatographic columns (Shim-pack IC-C1) and injection valve (20μL) were located inside of the glove-box except the chromatographic pump. The elements of lanthanide group were separated by a gradient program of HPLC with α-hydroxyisobutyric acid. Isotopic compositions of lanthanides in eluate was sequentially analyzed by a quadruple ICP-MS. Optimization of parameter of HPLC and ICP-MS measurement system was examined with standard solutions containing 14 lanthanide elements. The elements of lanthanides were separated by HPLC and detected by ICP-MS within 25 minutes. The detection limits of Nd-146, Sm-147 and Gd-157 were 0.37 μg L -1 , 0.69 μg L -1 and 0.47 μg L -1 , respectively. The analytical precision of the above three isotopes was better than 10% for standard solutions of 100 μg L -1 with

  9. Feature Fusion of ICP-AES, UV-Vis and FT-MIR for Origin Traceability of Boletus edulis Mushrooms in Combination with Chemometrics.

    Science.gov (United States)

    Qi, Luming; Liu, Honggao; Li, Jieqing; Li, Tao; Wang, Yuanzhong

    2018-01-15

    Origin traceability is an important step to control the nutritional and pharmacological quality of food products. Boletus edulis mushroom is a well-known food resource in the world. Its nutritional and medicinal properties are drastically varied depending on geographical origins. In this study, three sensor systems (inductively coupled plasma atomic emission spectrophotometer (ICP-AES), ultraviolet-visible (UV-Vis) and Fourier transform mid-infrared spectroscopy (FT-MIR)) were applied for the origin traceability of 192 mushroom samples (caps and stipes) in combination with chemometrics. The difference between cap and stipe was clearly illustrated based on a single sensor technique, respectively. Feature variables from three instruments were used for origin traceability. Two supervised classification methods, partial least square discriminant analysis (FLS-DA) and grid search support vector machine (GS-SVM), were applied to develop mathematical models. Two steps (internal cross-validation and external prediction for unknown samples) were used to evaluate the performance of a classification model. The result is satisfactory with high accuracies ranging from 90.625% to 100%. These models also have an excellent generalization ability with the optimal parameters. Based on the combination of three sensory systems, our study provides a multi-sensory and comprehensive origin traceability of B. edulis mushrooms.

  10. Feature Fusion of ICP-AES, UV-Vis and FT-MIR for Origin Traceability of Boletus edulis Mushrooms in Combination with Chemometrics

    Directory of Open Access Journals (Sweden)

    Luming Qi

    2018-01-01

    Full Text Available Origin traceability is an important step to control the nutritional and pharmacological quality of food products. Boletus edulis mushroom is a well-known food resource in the world. Its nutritional and medicinal properties are drastically varied depending on geographical origins. In this study, three sensor systems (inductively coupled plasma atomic emission spectrophotometer (ICP-AES, ultraviolet-visible (UV-Vis and Fourier transform mid-infrared spectroscopy (FT-MIR were applied for the origin traceability of 184 mushroom samples (caps and stipes in combination with chemometrics. The difference between cap and stipe was clearly illustrated based on a single sensor technique, respectively. Feature variables from three instruments were used for origin traceability. Two supervised classification methods, partial least square discriminant analysis (FLS-DA and grid search support vector machine (GS-SVM, were applied to develop mathematical models. Two steps (internal cross-validation and external prediction for unknown samples were used to evaluate the performance of a classification model. The result is satisfactory with high accuracies ranging from 90.625% to 100%. These models also have an excellent generalization ability with the optimal parameters. Based on the combination of three sensory systems, our study provides a multi-sensory and comprehensive origin traceability of B. edulis mushrooms.

  11. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K. E-mail: k_tagami@nirs.go.jp; Uchida, S.; Hamilton, T.; Robison, W

    2000-07-15

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g{sup -1} dry weight (dw). The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g{sup -1} dw under standard operating conditions.

  12. Evaluation of fracturing process of soft rocks at great depth by AE measurement and DEM simulation

    International Nuclear Information System (INIS)

    Aoki, Kenji; Mito, Yoshitada; Kurokawa, Susumu; Matsui, Hiroya; Niunoya, Sumio; Minami, Masayuki

    2007-01-01

    The authors developed the stress-based evaluation system of EDZ by AE monitoring and Distinct Element Method (DEM) simulation. In order to apply this system to the soft rock site, the authors try to grasp the relationship between AE parameters, stress change and rock fracturing process by performing the high stiffness tri-axial compression tests including AE measurements on the soft rock samples, and its simulations by DEM using bonded particle model. As the result, it is found that change in predominant AE frequency is effective to evaluate fracturing process in sedimentary soft rocks, and the relationship between stress change and fracturing process is also clarified. (author)

  13. Determination of the mineral compositions of some selected oil-bearing seeds and kernels using Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES

    Directory of Open Access Journals (Sweden)

    Musa Özcan, M.

    2006-06-01

    Full Text Available The aim of this paper was to establish the mineral contents of oil-bearing seeds and kernels such as peanut, turpentine, walnut, hazelnut, sesame, corn, poppy, almond, sunflower etc., using Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES. Significant differences in mineral composition were observed among crops. All seeds and kernels contained high amounts of Al, Ca, Fe, K, Mg, Na, P and Zn. B, Cr, Cu, Li, Ni, Sr, Ti while V contents of the crops were found to be very low. The levels of K and P of all crops in this study were found to be higher than those of other seeds and kernels. The results obtained from analyses of the crops showed that the mean levels of potassiumcontent ranged from 1701.08 mg/kg (corn to 20895.8 mg/kg (soybean, the average content of phosphorus ranged from 3076.9 mg/kg (turpentine to 12006,5 mg/kg to 2617.4 mg/kg (cotton seed, and Ca from 68.4 mg/kg (corn to 13195.7 mg/kg (poppy seed. The results show that these values may  be useful for the evaluation of dietary information. Particularly the obtained results provide evidence that soybean, pinestone and poppy seed are a good source of K, P and Ca, respectively. Whereas pinestone is a good source of zinc.La finalidad del trabajo es establecer el contenido en elementos minerales de semillas oleaginosas tales como cacahuetes, trementina, avellana, sesamo, maiz, almendras, girasol, utilizando ICP-AES. Se han observado diferencias significativas en la composición de minerales entre cosechas. Todas las semillas contienen cantidades elevadas de Al, Ca, Fe, K, Mg, Na, P y Zn. Los contenidos de B, Cr, Cu, Li, Ni, Sr, Ti y V, sin embargo, fueron bajos. Los contenidos de K y P en todas las semillas estudiadas fueron superiores a las de otras semillas. El contenido medio de K osciló entre 1.701,1 mg/kg (maiz a 20.895,8 mg/kg (soja, el P entre 3.076.9 mg/kg (trementina a 12.006.5 mg/kg o 2.617,4 mg/kg (semilla de algodón, y Ca de 68,4 mg/kg (maiz a 13.195,7 mg

  14. ICP measurement accuracy: the effect of temperature drift. Design of a laboratory test for assessment of ICP transducers.

    Science.gov (United States)

    Morgalla, M H; Mettenleiter, H; Katzenberger, T

    1999-01-01

    Intracranial pressure (ICP) monitoring has become the mainstay of multimodal neuromonitoring of comatous patients after head injury. In the presence of rising ICP and faced with pressures, difficult to control, aggressive measures, such as hypothermia may be used. The ICP readings should not be influenced by temperature changes. A laboratory test was designed to simulate temperature variations between 20 degrees C and 45 degrees C at different pressure levels under physiological conditions. Five types of transducers were examined: Epidyn Braun Melsungen, ICT/B-Titan Gaeltec, Camino-OLM-110-4B, Codman MicroSensor ICP-Transducer, Neurovent ICP transducer Rehau Ag+Co. Tests were performed at 6 different pressure levels between 0 mmHg and 50 mmHg. The results show very low drifts of less than 0.15 mmHg degree C-1 for Codman, Epidyn and Neurovent. Gaeltec and Camino exhibited higher drifts of 0.18 mmHg and 0.2 mmHg degree C-1 respectively. Within the temperature range from 35 degrees C to 42 degrees C all probes tested show insignificant temperature drift. Whether these results also apply to other types of transducers needs further evaluation. Problems and requirements related to the design of a laboratory test for the in vitro assessment of ICP transducers are discussed in detail.

  15. New application and future of ICP-MS

    International Nuclear Information System (INIS)

    Masuda, Kimihiko

    1994-01-01

    By ICP-MS, since high sensibility, multi-element rapid analysis and isotope ratio analysis can be carried out, the position as the analysis for ultra-minute amount of elements has been established. Further recently, sample feeder system has been developed, and the multi-collector type device for the purpose of high resolution type isotope ratio analysis has appeared, so the range of its application is spreading more and more. In this report, the examples of application which were able to be attained accompanying the development of these devices are introduced, and the development of the ICP-MS hereafter is described. At present, about 1000 apparatuses are in operation in the world, and the application spread to the fields of semiconductors and materials, earth science, environment, atomic energy and so on. The ICP-MS was developed for the purpose of easily carrying out spectral analysis with high sensibility by using argon ICP as the ion source and doing ion detection which is more efficient than light detection, and has lower background. The progress and the present status of the ICP-MS are reported. As the latest examples of application of the ICP-MS, the analysis of iron by quadrupole type ICP-MS, the small region measurement of solids by laser abrasion, ultra-minute amount analysis by high resolution ICP-MS, the isotope ratio measurement of lead by multi-collector type ICP-MS are reported. (K.I.)

  16. Flotation-separation and ICP-AES determination of ultra trace amounts of copper, cadmium, nickel and cobalt using 2-aminocyclopentene-1-dithiocarboxylic acid.

    Science.gov (United States)

    Shamsipur, Mojtaba; Hashemi, Omid Reza; Safavi, Afsaneh

    2005-09-01

    A rapid flotation method for separation and enrichment of ultra trace amounts of copper(II), cadmium(II), nickel(II) and cobalt(II) ions from water samples is established. At pH 6.5 and with sodium dodecylsulfate used as a foaming reagent, Cu2+, Cd2+, Ni2+ and Co2+ were separated simultaneously with 2-aminocyclopentene-1-dithiocarboxylic acid (ACDA) added to 1 l of aqueous solution. The proposed procedure of preconcentration is applied prior to the determination of these four analytes using inductivity coupled plasma-atomic emission spectrometry (ICP-AES). The effects of pH, concentration of ACDA, applicability of different surfactants and foreign ions on the separation efficiency were investigated. The preconcentration factor of the method is 1000 and the detection limits of copper(II), cadmium(II), nickel(II) and cobalt(II) ions are 0.078, 0.075, 0.072 and 0.080 ng ml(-1), respectively.

  17. Spectral lines and coincidence tables for the determination of zirconium, niobium and tantalum with the ICP

    International Nuclear Information System (INIS)

    Wuensch, G.; Wennemer, A.

    1987-01-01

    Coincidence tables for ICP-AES are given for 20 Zr lines, 9 Nb lines and 7 Ta lines. They include 582 interferent lines of 49 elements. The specified interference data (IEC and CCR) hold for a bandwidth FWHM = 16 pm and an interferent concentration of 1,000 mg/l. For trace determinations of Zr, Nb, Ta in a matrix of Fe, Z, Zr, Nb, Ta the dependence of the interference on the matrix concentration is specified up to 10,000 mg/l. Interference data CCR calculated for the ICP from the NBS tables often differ from the measured data by several orders of magnitude. The spectrum of Zr measured at a high concentration shows many weak lines most of which are not even listed in the MIT tables. They give rise to a quasi-continuous background the intensity of which increases nearly linearly with the matrix concentration. Therefore, an increase of sample concentration will not lead to an improved detection limit. The line intensities found in our investigations match well with those listed in the Wohlers tables. (orig.)

  18. Determination of the structure and composition of Au-Ag bimetallic spherical nanoparticles using single particle ICP-MS measurements performed with normal and high temporal resolution.

    Science.gov (United States)

    Kéri, Albert; Kálomista, Ildikó; Ungor, Ditta; Bélteki, Ádám; Csapó, Edit; Dékány, Imre; Prohaska, Thomas; Galbács, Gábor

    2018-03-01

    In this study, the information that can be obtained by combining normal and high resolution single particle ICP-MS (spICP-MS) measurements for spherical bimetallic nanoparticles (BNPs) was assessed. One commercial certified core-shell Au-Ag nanoparticle and three newly synthesized and fully characterized homogenous alloy Au-Ag nanoparticle batches of different composition were used in the experiments as BNP samples. By scrutinizing the high resolution spICP-MS signal time profiles, it was revealed that the width of the signal peak linearly correlates with the diameter of nanoparticles. It was also observed that the width of the peak for same-size nanoparticles is always significantly larger for Au than for Ag. It was also found that it can be reliably determined whether a BNP is of homogeneus alloy or core-shell structure and that, in the case of the latter, the core comprises of which element. We also assessed the performance of several ICP-MS based analytical methods in the analysis of the quantitative composition of bimetallic nanoparticles. Out of the three methods (normal resolution spICP-MS, direct NP nebulization with solution-mode ICP-MS, and solution-mode ICP-MS after the acid dissolution of the nanoparticles), the best accuracy and precision was achieved by spICP-MS. This method allows the determination of the composition with less than 10% relative inaccuracy and better than 3% precision. The analysis is fast and only requires the usual standard colloids for size calibration. Combining the results from both quantitative and structural analyses, the core diameter and shell thickness of core-shell particles can also be calculated. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Determination of {sup 126}Sn half-life from ICP-MS and gamma spectrometry measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bienvenu, P.; Arnal, N.; Comte, J. [CEA Cadarache DEN/DEC/SA3C/LARC, Paul Lez Durance (France); Ferreux, L.; Lepy, M.C.; Be, M.M. [CEA Saclay LIST LNE/LNHB, Gif sur Yvette (France); Andreoletti, G. [AREVA Cogema SL/UP2-800, Beaumont Hague (France)

    2009-07-01

    A new value of {sup 126}Sn half-life was determined by combination of inductively coupled plasma-mass spectrometry (ICP-MS) and gamma spectrometry measurements on purified sample solutions collected from nuclear fuel reprocessing. {sup 126}Sn was isolated through dissolution of fission product precipitates and liquid-liquid extraction with N-benzoyl-N-phenyl-hydroxylamine (BPHA). The abundance of {sup 126}Sn atoms together with the absence of interfering species in the analysed solutions made it possible to measure both mass concentration and nuclide activity with high precision and accuracy. This led to a {sup 126}Sn half-life value of 1.980 (57) x 10{sup 5} a. (orig.)

  20. [Progress in the application of laser ablation ICP-MS to surface microanalysis in material science].

    Science.gov (United States)

    Zhang, Yong; Jia, Yun-hai; Chen, Ji-wen; Shen, Xue-jing; Liu, Ying; Zhao, Leiz; Li, Dong-ling; Hang, Peng-cheng; Zhao, Zhen; Fan, Wan-lun; Wang, Hai-zhou

    2014-08-01

    In the present paper, apparatus and theory of surface analysis is introduced, and the progress in the application of laser ablation ICP-MS to microanalysis in ferrous, nonferrous and semiconductor field is reviewed in detail. Compared with traditional surface analytical tools, such as SEM/EDS (scanning electron microscopy/energy dispersive spectrum), EPMA (electron probe microanalysis analysis), AES (auger energy spectrum), etc. the advantage is little or no sample preparation, adjustable spatial resolution according to analytical demand, multi-element analysis and high sensitivity. It is now a powerful complementary method to traditional surface analytical tool. With the development of LA-ICP-MS technology maturing, more and more analytical workers will use this powerful tool in the future, and LA-ICP-MS will be a super star in elemental analysis field just like LIBS (Laser-induced breakdown spectroscopy).

  1. Microwave digestion techniques applied to determination of boron by ICP-AES in BNCT program

    International Nuclear Information System (INIS)

    Farias, Silvia S.; Di Santo, Norberto R.; Garavaglia, Ricardo N.; Pucci, Gladys N.; Batistoni, Daniel A.; Schwint, Amanda E.

    1999-01-01

    Recently, boron neutron capture therapy (BNCT) has merged as an interesting option for the treatment of some kind of tumors where established therapies show no success. A molecular boronated species, enriched in 10 B is administrated to the subject; it localizes in malignant tissues depending the kind of tumor and localization. Therefore, a very important fact in BNCT research is the detection of boron at trace or ultra trace levels precisely and accurately. This is extremely necessary as boronated species do localize in tumoral tissue and also localize in liver, kidney, spleen, skin, membranes. By this way, before testing a boronated species, it is mandatory to determine its biodistribution in a statistically meaning population, that is related with managing of a great number of samples. In the other hand, it is necessary to exactly predict when to begin the irradiation and to determine the magnitude of radiation to obtain the desired radiological dose for a specified mean boron concentration. This involves the determination of boron in whole blood, which is related with boron concentration in the tumor object of treatment. The methodology selected for the analysis of boron in whole blood and tissues must join certain characteristics: it must not be dependant of the chemical form of boron, it has to be fast and capable to determine boron accurately and precisely in a wide range of concentrations. The design and validation of experimental models involving animals in BNCT studies and the determination of boron in blood of animals and subjects upon treatment require reliable analytical procedures to determine boron quantitatively in those biologic materials. Inductively coupled plasma-atomic emission spectrometry (ICP-AES) using pneumatic nebulization is one of the most promising methods for boron analysis, but the sample must be liquid and have low solid concentration. In our case, biological tissues and blood, it is mandatory to mineralize and/or dilute samples

  2. A high performance hardware implementation image encryption with AES algorithm

    Science.gov (United States)

    Farmani, Ali; Jafari, Mohamad; Miremadi, Seyed Sohrab

    2011-06-01

    This paper describes implementation of a high-speed encryption algorithm with high throughput for encrypting the image. Therefore, we select a highly secured symmetric key encryption algorithm AES(Advanced Encryption Standard), in order to increase the speed and throughput using pipeline technique in four stages, control unit based on logic gates, optimal design of multiplier blocks in mixcolumn phase and simultaneous production keys and rounds. Such procedure makes AES suitable for fast image encryption. Implementation of a 128-bit AES on FPGA of Altra company has been done and the results are as follow: throughput, 6 Gbps in 471MHz. The time of encrypting in tested image with 32*32 size is 1.15ms.

  3. Determination of 25 trace impurity elements in U3O8 by horizontal ICP-AES after separation with TBP levextrel resin chromatography

    International Nuclear Information System (INIS)

    Guan Jingsu; Shi Youqing; Gao Binghua; Liu Yingmei

    1988-01-01

    A method for the determination of Al, As, Ba, Be, Bi, Ca, Cd, Cu, Co, Cr, Fe, Mg, Mn, Mo, Ni, P, Pb, Ru, Sb, Sn, Sr, Ti, V, W and Zn 25 trace elements in U 3 O 8 is reported. The sample is dissolved in HNO 3 or HNO 3 -HCLO 4 -HF and the uranium is separated by TBP Levextrel resin chromatogyaphy. The impurity elements containing in the aquaous phase are determined by horizontal ICp-AES method. With a sample of 300 mg, the detection limit for all the 25 elements is in the range of 0.01∼5ppm, the recovery is in the range of 82∼ 121%, the determination precision (RSD) is less than ±13%. 18 trace elements in reference material of U 3 O 8 prepared in China are determined, the values obtained well with the values of overall median of accepted laboratory means

  4. [Determination of ru, rh and Pd in 30% trialkyl phosphine oxide (TRPO)-kerosene by inductively coupled plasma-atomic emission spectrum (ICP-AES)].

    Science.gov (United States)

    Wang, Jian-Chen; Zhang, Lin

    2013-07-01

    The determination method of Ru, Rh and Pd in 30% TRPO-kerosene ICP-AES was studied by using aqueous calibration reference solution and choosing ethanol as diluent. The effects of the contents of 30% TRPO-kerosene and aqueous solution and the concentration of HNO3 in 30% TRPO-kerosene on the intensities of Ru, Rh and Pd were described. The optimized condition for preparing samples and calibration solutions was chosen as follows: The contents of 30% TRPO-kerosene and aqueous phase were 10% (V/V) and 5% (V/V) respectively and the concentration of HNO3 30% TRPO-kerosene was 0.20 mol x L(-1). The determination method of Au, Ru and Pd was set up according to the above condition. The detection limit, precision and recovery ratio of Ru, Rh and Pd are well. The method is not only used in determination of Au, Ru and Pd in 30% TRPO-kerosene, but also used in other organic phases.

  5. Power efficient and high performance VLSI architecture for AES algorithm

    Directory of Open Access Journals (Sweden)

    K. Kalaiselvi

    2015-09-01

    Full Text Available Advanced encryption standard (AES algorithm has been widely deployed in cryptographic applications. This work proposes a low power and high throughput implementation of AES algorithm using key expansion approach. We minimize the power consumption and critical path delay using the proposed high performance architecture. It supports both encryption and decryption using 256-bit keys with a throughput of 0.06 Gbps. The VHDL language is utilized for simulating the design and an FPGA chip has been used for the hardware implementations. Experimental results reveal that the proposed AES architectures offer superior performance than the existing VLSI architectures in terms of power, throughput and critical path delay.

  6. Rapid Separation Methods to Characterize Actinides and Metallic Impurities in Plutonium Scrap Materials at SRS

    International Nuclear Information System (INIS)

    Maxwell, S.L. III; Jones, V.D.

    1998-07-01

    The Nuclear Materials Stabilization and Storage Division at SRS plans to stabilize selected plutonium scrap residue materials for long term storage by dissolution processing and plans to stabilize other plutonium vault materials via high-temperature furnace processing. To support these nuclear material stabilization activities, the SRS Analytical Laboratories Department (ALD) will provide characterization of materials required prior to the dissolution or the high-firing of these materials. Lab renovations to install new analytical instrumentation are underway to support these activities that include glove boxes with simulated-process dissolution and high- pressure microwave dissolution capability. Inductively-coupled plasma atomic emission spectrometry (ICP-AES), inductively- coupled mass spectrometry (ICP-MS) and thermal-ionization mass spectrometry (TIMS) will be used to measure actinide isotopics and metallic impurities. New high-speed actinide separation methods have been developed that will be applied to isotopic characterization of nuclear materials by TIMS and ICP-MS to eliminate isobaric interferences between Pu-238 /U- 238 and Pu-241/Am-241. TEVA Resin, UTEVA Resin, and TRU Resin columns will be used with vacuum-assisted flow rates to minimize TIMS and ICP-MS sample turnaround times. For metallic impurity analysis, rapid column removal methods using UTEVA Resin, AGMP-1 anion resin and AG MP-50 cation resin have also been developed to remove plutonium and uranium matrix interferences prior to ICP-AES and ICP- MS measurements

  7. Uranium spectra in the ICP

    Energy Technology Data Exchange (ETDEWEB)

    Ghazi, A.A.; Qamar, S.; Atta, M.A. (Khan (A.Q.) Research Labs., Rawalpindi (Pakistan))

    1994-05-01

    Uranium spectra have been studied by inductively coupled plasma atomic emission spectroscopy (ICP-AES). In total, 8361 uranium lines were observed in the wavelength range of 235-500 nm. This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hard copy text is accompanied by a disk with data files and test files for an IBM-compatible computer. The main article discusses the scientific aspects of the subject and explains the purpose of the data files. (Author).

  8. Uranium spectra in the ICP

    International Nuclear Information System (INIS)

    Ghazi, A.A.; Qamar, S.; Atta, M.A.

    1994-01-01

    Uranium spectra have been studied by inductively coupled plasma atomic emission spectroscopy (ICP-AES). In total, 8361 uranium lines were observed in the wavelength range of 235-500 nm. This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hard copy text is accompanied by a disk with data files and test files for an IBM-compatible computer. The main article discusses the scientific aspects of the subject and explains the purpose of the data files. (Author)

  9. Eletrodissolução de ligas de latão empregando sistemas de análise em fluxo para a determinação de cobre, zinco e chumbo por ICP-AES Electrodissolution of brasses alloys employing flow systems for determination of copper, zinc and lead by ICP-AES

    Directory of Open Access Journals (Sweden)

    Ana Paula G. Gervasio

    1999-09-01

    Full Text Available An on-line electrodissolution procedure implemented in a flow injection system for determination of copper, zinc and lead in brasses alloys by ICP-AES is described. Sample dissolution procedure was carried out by using a PTFE chamber and a DC power supply with constant current. Solid sample was attached to chamber as anode and a gold tubing coupled in the chamber was used as cathode. An electrolytic solution flowing through the gold tubing closed the electric circuit with sample, in order to provide condition for electric dissolution when the DC power supply was switched on. The best results were achieved by using a 1.5 mol l-1 nitric acid solution as electrolyte and a 2.5 A current intensity. The procedure presented a good performance characterized by a relative standard deviation better than < 5% (n=5 and a sample throughput of 180 determinations per hour for Cu, Zn and Pb. Results were in agreement with those obtained by conventional acid dissolution (99% confidence level.

  10. Isotope ratio measurements of uranium by LA-HR-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Marin, Rafael C.; Sarkis, Jorge E.S., E-mail: rafael.marin@usp.b, E-mail: jesarkis@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    This work describes the utilization of Laser Ablation High Resolution Inductively Mass Spectrometry (LA-HR-ICP-MS) technique for the determination of uranium isotope composition in a UO{sub 2} pellet (CRM -125A) supplied and certified by the New Brunswick Laboratory (NBL). To carry out the adjustments of the parameters was used a glass standard NIST 610, supplied and certified by National Institute of Standards and Technology (NIST). The precision of the measurements were improved by adjusting the following parameters: RF power, laser beam diameter, defocusing of laser beam, laser energy, laser energy-density, auxiliary gas and sample gas. The measurements were performed on a continuous ablation with low energy density and defocusing, which demonstrated to be the optimum to reach the best signal stability. Isotope ratios, {sup 234}U/{sup 238}U, {sup 235}U/{sup 238}U and {sup 236}U/{sup 238}U were measured, reaching relative standard deviations (RSD) from 1.55% to 7.60%. The parameters which caused the greatest impact in order to improve the signal stability were RF power, defocusing and laser beam diameter. The results presented by the measurements revealed that the Laser ablation ICP-MS technique offers a rapid and accurate way to perform uranium isotope ratios without any sample preparation, since it allows carrying out the measurements straight on the sample, besides to preserve the testimony that is very important for safeguards and nuclear forensics purposes. (author)

  11. AE characteristic for monitoring of fatigue crack in steel bridge members

    Science.gov (United States)

    Yoon, Dong-Jin; Jung, Juong-Chae; Park, Philip; Lee, Seung-Seok

    2000-06-01

    Acoustic emission technique was employed for the monitoring of crack activity in both steel bridge members and laboratory specimen. Laboratory experiment was carried out to identify AE characteristics of fatigue cracks for compact tension specimen. The relationship between a stress intensity factor and AE signals activity as well as conventional AE parameter analysis was discussed. A field test was also conducted on a railway bridge, which contain several fatigue cracks. Crack activities were investigated while in service with strain measurement. From the results, in the laboratory tests, the features of three parameters such as the length of crack growth, the AE energy, and the cumulative AE events, showed the almost same trend in their increase as the number of fatigue cycle increased. From the comparisons of peak amplitude and AE energy with stress intensity factor, it was verified that the higher stress intensity factors generated AE signals with higher peak amplitude and a large number of AE counts. In the field test, real crack propagation signals were captured and the crack activity was verified in two cases.

  12. Surface modification of ceramic materials induced by irradiation of high power pulsed ICP

    International Nuclear Information System (INIS)

    Ishigaki, Takamasa; Okada, Nobuhiro; Ohashi, Naoki; Haneda, Hajime

    2003-01-01

    Newly developed pulse-modulated high-power inductively coupled plasma [ICP] is expected to offer the unique physico-chemical condition, such as the increased concentration of chemically reactive species, as well as the appropriate heat flux for materials processing. Two kinds of oxide materials, titanium and zinc oxide, were placed at the downstream of Ar-H 2 ICP and irradiated in the plasma of continuous [CN] and pulse-modulated [PM] modes. The CN-ICP irradiation at the position close to the plasma tail gave rise to the thermal reduction of oxides. In the PM-ICP irradiation, the degree of thermal reduction depended on the lower power level during pulse-off time, as well as the total electric power. Irradiation in PM-ICP led to the increased formation of oxygen vacancies in titanium dioxide. In the case of zinc oxide, the UV emission efficiency was improved by PM-ICP irradiation, while the green emission became predominant by CN-ICP irradiation at the appropriate position. Induced effects in the two oxides by PM-ICP would be related to the high concentration of hydrogen radicals in the plasma. (author)

  13. AE monitoring instrumentation for high performance superconducting dipoles and quadrupoles, Phase 2

    Science.gov (United States)

    Iwasa, Y.

    1986-01-01

    In the past year and a half, attention has been focused on the development of instrumentation for on-line monitoring of high-performance superconducting dipoles and quadrupoles. This instrumentation has been completed and satisfactorily demonstrated on a prototype Fermi dipole. Conductor motion is the principal source of acoustic emission (AE) and the major cause of quenches in the dipole, except during the virgin run when other sources are also present. The motion events are mostly microslips. The middle of the magnet is most susceptible to quenches. This result agrees with the peak field location in the magnet. In the virgin state the top and bottom of the magnet appeared acoustically similar but diverged after training, possibly due to minute structural asymmetry, for example differences in clamping and welding strength; however, the results do not indicate any major structural defects. There is good correlation between quench current and AE starting current. The correlation is reasonable if mechanical disturbances are indeed responsible for quench. Based on AE cumulative history, the average frictional power dissipation in the whole dipole winding is estimated to be approx. 10 (MU)W cm(-3). We expect to implement the following in the next phase of this project: Application of room-temperature techniques to detecting structural defects in the dipole; application of the system to other dipoles and quadrupoles in the same series to compare their performances; and further investigation of AE starting current approx. quench current relationship. Work has begun on the room temperature measurements. Preliminary Stress Wave Factor measurements have been made on a model dipole casing.

  14. Characterisation of Supra- and Infratentorial ICP Profiles.

    Science.gov (United States)

    Moyse, Emmanuel; Ros, Maxime; Marhar, Fouad; Swider, Pascal; Schmidt, Eric Albert

    2016-01-01

    In pathophysiology and clinical practice, the intracranial pressure (ICP) profiles in the supratentorial and infratentorial compartments are unclear. We know that the pressure within the skull is unevenly distributed, with demonstrated ICP gradients. We recorded and characterised the supra- and infratentorial ICP patterns to understand what drives the transtentorial ICP gradient.A 70-year-old man was operated on for acute cerebellar infarction. One supratentorial probe and one cerebellar probe were implanted. Both signals were recorded concurrently and analysed off-line. We calculated mean ICP, ICP pulse amplitude, respiratory waves, slow waves and the RAP index of supra- and infratentorial ICP signals. Then, we measured transtentorial difference and performed correlation analysis for every index.Supratentorial ICP mean was 8.5 mmHg lower than infratentorial ICP, but the difference lessens for higher values. Both signals across the tentorium showed close correlation. Supra- and infratentorial pulse amplitude, respiratory waves and slow waves also showed a high degree of correlation. The compensatory reserve (RAP) showed good correlation. In this case report, we demonstrate that the mean value of ICP is higher in the posterior fossa, with a strong correlation across the tentorium. All other ICP-derived parameters display a symmetrical profile.

  15. [Analysis of mineral elements of sunflower (Helianthus annuus L.) grown on saline land in Hetao Irrigation District by ICP-AES].

    Science.gov (United States)

    Tong, Wen-Jie; Chen, Fu; Wen, Xin-Ya

    2014-01-01

    The absorption and accumulation of ten mineral elements in four kinds of organs (root, steam, leaf and flower disc) in Helianthus annuus L. plants cultured in Hetao Irrigation District under different level of salinity stress were determined by ICP-AES with wet digestion (HNO3 + HClO4). The results showed that: (1) The contents of Fe, Mn, Zn, Ca, and Na were highest in roots, so was K in stems, B and Mg in leaves and P in flower discs, while no significant difference was detected in the content of Cu among these organs; (2) The cumulants of Ca, Mg, P, Cu, B and Zn were highest in flower discs, so were Na, Fe and Mn in roots and K in stems; (3) In sunflower plants, the proportion of mineral element cumulant for K : Ca : Mg : P : Na was 16.71 : 5.23 : 3.86 : 1.23 : 1.00, and for Zn : Fe : B : Mn: Cu was 56.28 : 27.75 : 1.93 : 1.17 : 1.00, respectively; (4) The effect of salinity stress on absorption of mineral elements differed according to the kind of organ and element, root was the most sensitive to soil salt content, followed by stem and leaf, and the effect on flower disc seemed complex.

  16. Determination of rare earth elements by liquid chromatography/inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Yoshida, K.; Haraguchi, H.

    1984-01-01

    Inductively coupled plasma atomic emission spectrometry (ICP-AES) interfaced with high-performance liquid chromatography (HPLC) has been applied to the determination of rare earth elements. ICP-AES was used as an element-selective detector for HPLC. The separation of rare earth elements with HPLC helped to avoid erroneous analytical results due to spectral interferences. Fifteen rare earth elements (Y and 14 lanthanides) were determined selectively with the HPLC/ICP-AES system using a concentration gradient method. The detection limits with the present HPLC/ICP-AES system were about 0.001-0.3 μg/mL with a 100-μL sample injection. The calibration curves obtained by the peak height measurements showed linear relationships in the concentration range below 500 μg/mL for all rare earth elements. A USGS rock standard sample, rare earth ores, and high-purity lanthanide reagents (>99.9%) were successfully analyzed without spectral interferences

  17. Post hoc interlaboratory comparison of single particle ICP-MS size measurements of NIST gold nanoparticle reference materials.

    Science.gov (United States)

    Montoro Bustos, Antonio R; Petersen, Elijah J; Possolo, Antonio; Winchester, Michael R

    2015-09-01

    Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that enables simultaneous measurement of nanoparticle size and number quantification of metal-containing nanoparticles at realistic environmental exposure concentrations. Such measurements are needed to understand the potential environmental and human health risks of nanoparticles. Before spICP-MS can be considered a mature methodology, additional work is needed to standardize this technique including an assessment of the reliability and variability of size distribution measurements and the transferability of the technique among laboratories. This paper presents the first post hoc interlaboratory comparison study of the spICP-MS technique. Measurement results provided by six expert laboratories for two National Institute of Standards and Technology (NIST) gold nanoparticle reference materials (RM 8012 and RM 8013) were employed. The general agreement in particle size between spICP-MS measurements and measurements by six reference techniques demonstrates the reliability of spICP-MS and validates its sizing capability. However, the precision of the spICP-MS measurement was better for the larger 60 nm gold nanoparticles and evaluation of spICP-MS precision indicates substantial variability among laboratories, with lower variability between operators within laboratories. Global particle number concentration and Au mass concentration recovery were quantitative for RM 8013 but significantly lower and with a greater variability for RM 8012. Statistical analysis did not suggest an optimal dwell time, because this parameter did not significantly affect either the measured mean particle size or the ability to count nanoparticles. Finally, the spICP-MS data were often best fit with several single non-Gaussian distributions or mixtures of Gaussian distributions, rather than the more frequently used normal or log-normal distributions.

  18. Health impacts of mercury cycling in contaminated environments of Central India studied by NAA and ICP-MS

    International Nuclear Information System (INIS)

    Patel, Khageshwar Singh

    2002-01-01

    The environmental and atmospheric samples i.e. surface water, ground water, surface soil, sediment, rain and fog from various sites of contaminated environments of central India were collected in year, 2000-2001. The concentration levels of total-Hg in these samples were analyzed by using techniques i.e. cold vapor- atomic absorption spectrophotometer (CV-AAS), X-ray fluorescence spectrophotometer XFS). Further, the data base of total Hg in the environmental samples would be validated in other laboratories i.e. Prof Dr. Klaus Heumann (Johannes Gutenberg-University, Mainz, Germany), David Amouroux (University of Pau, France) and Dr Joerg Feldmann (University of Aberdeen, Scotland, UK) for exploration of the Hg-contaminated environments by using techniques i.e. ICP-MS/GC, gas chromatography-induced couple atomic emission spectrophotometer (GC-ICP-AES), neutron activation analysis (NAA). (author)

  19. [Mineral elements analysis of Momordica charantiap seeds by ICP-AES and fatty acid profile identification of seed oil by GC-MS].

    Science.gov (United States)

    Liu, Xiao-ru; Deng, Ze-yuan; Fan, Ya-wei; Li, Jing; Liu, Zhi-han

    2010-08-01

    In the present study, a special kind of Momordica charantia seeds produced in Hai Nan was selected and analyzed. Firstly, inductively coupled plasma-atomic emission spectrophotometry (ICP-AES) was used to determine the mineral elements. It was clear that the contents of K, Mg and P are the highest in the seeds; Cr and Zn takes up to 5.65% and 45.45% high, especially, which are rare in plant foods. These minerals, especially Cr and Zn might have a complex effect on those proteins or polysaccharides and form a stronger anticipation of hyperlipidemia, hyperglycemia and cholesterol. Secondly, seed oil was extracted by supercritical CO2 extraction with a yield ratio of 36.89, and the fatty acids were treated by methylation in alkaline process and purified by thin-layer chromatography, then analyzed by gas chromatography-mass spectrometer (GC-MS) identification. The saturated fatty acids (SFA) take up 36.712, and mainly are stearic acid; monounsaturated fatty acid (MUFA) is only 3.33% which is dominantly linoleic acid (LA); Polyunsaturated fatty acid (PUFA) accounted for 59.96%, and the alpha-eleostearic acid takes up 54.26% as the main fatty acids in all. The plentiful alpha-eleostearic acid leads to strong effects of inhibiting tumor cell proliferation, lowering blood fat, anti-cancer, anti-inflammatory and preventing cardiovascular diseases, and so on. Knowing clearly the mineral elements distribution and identifying the composition of fatty acid, especially the main fatty acids in the oil, are both of great guiding importance to further exploit the clinical and edible value in Momordica charantiap seeds.

  20. Elemental speciation via high-performance liquid chromatography combined with inductively coupled plasma atomic emission spectroscopic detection: application of a direct injection nebulizer

    International Nuclear Information System (INIS)

    LaFreniere, K.E; Fassel, V.A.; Eckels, D.E.

    1987-01-01

    An evaluation is presented of a direct injection nebulizer (DIN) interfaced to a high-performance liquid chromatograph (HPLC) with inductively coupled plasma atomic emission spectroscopic (ICP-AES) detection for simultaneous multielement speciation. The limits of detection (LODs) obtained with the DIN interface in the HPLC mode were found to be comparable to those obtained by continuous-flow sample introduction into the ICP, or inferior by up to only a factor of 4. In addition, the DIN allowed for the direct injection into the ICP of a variety of common HPLC solvents (up to 100% methanol, acetonitrile, methyl isobutyl ketone, pyridine, and water). The HPLC-DIN-ICP-AES system was compared to other HPLC-atomic spectroscopic detection techniques and was found to offer substantial improvement over the alternative on-line, detection methods in terms of LODs. Representative applications of the HPLC-DIN-ICP-AES system to the elemental speciation of coal process streams, shale oil, solvent refined coal, and crude oil are presented

  1. AE Test of Calcareous Sands with Particle Rushing

    Directory of Open Access Journals (Sweden)

    Tan Fengyi

    2017-08-01

    Full Text Available The particle of calcareous sands was forced to crush, then the energy from the crushing was released by the form of sound waves. Therefore the AE technique was used to detect the calcareous sands AE signal when it crushed. by to study the AE characteristics, the mechanics of calcareous sands was studied. Study showed that: (1 there was the AE activities on the low confining pressure condition at the beginnig of test, (2 there was more and more AE activities with the continuing of test until to the end, (3 the calcareous sands’ AE activities was on the whole testing, (4 the calcareous sands’ particle crushing and mutual friction played different roles for its AE activities. Then the AE model based on the calcarous sands’ particle crushing was discussed.

  2. Comparison of Time-of-flight and Multicollector ICP Mass Spectrometers for Measuring Actinides in Small Samples using single shot Laser Ablation

    International Nuclear Information System (INIS)

    R.S. Houk; D.B. Aeschliman; S.J. Bajic; D. Baldwin

    2005-01-01

    The objective of these experiments is to evaluate the performance of two types of ICP-MS device for measurement of actinide isotopes by laser ablation (LA) ICP-MS. The key advantage of ICP-MS compared to monitoring of radioactive decay is that the element need not decay during the measurement time. Hence ICP-MS is much faster for long-lived radionuclides. The LA process yields a transient signal. When spatially resolved analysis is required for small samples, the laser ablation sample pulse lasts only ∼10 seconds. It is difficult to measure signals at several isotopes with analyzers that are scanned for such a short sample transient. In this work, a time-of-flight (TOF) ICP-MS device, the GBC Optimass 8000 (Figure 1) is one instrument used. Strictly speaking, ions at different m/z values are not measured simultaneously in TOF. However, they are measured in very rapid sequence with little or no compromise between the number of m/z values monitored and the performance. Ions can be measured throughout the m/z range in single sample transients by TOF. The other ICP-MS instrument used is a magnetic sector multicollector MS, the NU Plasma 1700 (Figure 2). Up to 8 adjacent m/z values can be monitored at one setting of the magnetic field and accelerating voltage. Three of these m/z values can be measured with an electron multiplier. This device is usually used for high precision isotope ratio measurements with the Faraday cup detectors. The electron multipliers have much higher sensitivity. In our experience with the scanning magnetic sector instrument in Ames, these devices have the highest sensitivity and lowest background of any ICP-MS device. The ability to monitor several ions simultaneously, or nearly so, should make these devices valuable for the intended application: measurement of actinide isotopes at low concentrations in very small samples for nonproliferation purposes. The primary sample analyzed was an urban dust pellet reference material, NIST 1648. The

  3. Sulfur-induced offsets in MC-ICP-MS silicon-isotope measurements

    NARCIS (Netherlands)

    van den Boorn, S.; Vroon, P.Z.; van Bergen, M.J.

    2009-01-01

    Sample preparation methods for MC-ICP-MS silicon-isotope measurements often involve a cation-exchange purification step. A previous study has argued that this would suffice for geological materials, as the occasional enrichment of anionic species would not compromise silicon-isotope analysis. Here

  4. Sulphur-induced offsets in MC-ICP-MS silicon-isotope measurements

    NARCIS (Netherlands)

    van den Boorn, S.; Vroon, P.Z.; van Bergen, M.J.

    2010-01-01

    Sample preparation methods for MC-ICP-MS silicon-isotope measurements often involve a cation-exchange purification step. A previous study has argued that this would suffice for geological materials, as the occasional enrichment of anionic species would not compromise silicon-isotope analysis. Here

  5. Electron and ion temperatures: a comparison of ground-based incoherent scatter and AE-C satellite measurements

    International Nuclear Information System (INIS)

    Benson, R.F.; Bauer, P.; Brace, L.H.; Carlson, H.C.; Hagen, J.; Hanson, W.B.; Hoegy, W.R.; Torr, M.R.; Wickwar, V.B.

    1977-01-01

    The Atmosphere Exploere-C satellite (AE-C) is uniquely suited for correlative studies with ground-based stations because its on-board propulsion system enables a desired ground station overflight condition to be maintained for a period of several weeks. It also provides the first low-altitude (below 260 km) comparison of satellite and incoherent scatter electron and ion temperatures. More than 40 comparisons of remote and in situ measurements were made by using data from AE-C and four incoherent scatter stations (Arecibo, Chatanika, Millstone Hill, and St. Santin). The results indicate very good agreement between satellite and ground measurements of the ion temperature, the average satellite retarding potential analyzer temperatures differing from the average incoherent scatter temperatures by -2% at St. Santin, +3% at Millstone Hill, and +2% at Arecibo. The electron temperatures also agree well, the average satellite temperatures exceeding the average incoherent scatter temperatures by 3% at St. Santin, 2% at Arecibo, and 11% at Millstone Hill. Several temperature comparisons were made between AE-C and Chatanika. In spite of the highly variable ionosphere often encountered at this high-latitude location, good agreement was obtained between the in situ and remote measurements of electron and ion temperatures. Longitudinal variations are found to be very important in the comparisons of electron temperature in some locations. The agreement between the electron temperatures is considerably better than that found in some earlier comparisons involving satellities at higher altitudes

  6. CHANDRA HIGH-ENERGY TRANSMISSION GRATING SPECTRUM OF AE AQUARII

    International Nuclear Information System (INIS)

    Mauche, Christopher W.

    2009-01-01

    The nova-like cataclysmic binary AE Aqr, which is currently understood to be a former supersoft X-ray binary and current magnetic propeller, was observed for over two binary orbits (78 ks) in 2005 August with the High-Energy Transmission Grating (HETG) on board the Chandra X-ray Observatory. The long, uninterrupted Chandra observation provides a wealth of details concerning the X-ray emission of AE Aqr, many of which are new and unique to the HETG. First, the X-ray spectrum is that of an optically thin multi-temperature thermal plasma; the X-ray emission lines are broad, with widths that increase with the line energy from σ ∼ 1 eV (510 km s -1 ) for O VIII to σ ∼ 5.5 eV (820 km s -1 ) for Si XIV; the X-ray spectrum is reasonably well fit by a plasma model with a Gaussian emission measure distribution that peaks at log T(K) = 7.16, has a width σ = 0.48, an Fe abundance equal to 0.44 times solar, and other metal (primarily Ne, Mg, and Si) abundances equal to 0.76 times solar; and for a distance d = 100 pc, the total emission measure EM = 8.0 x 10 53 cm -3 and the 0.5-10 keV luminosity L X = 1.1 x 10 31 erg s -1 . Second, based on the f/(i + r) flux ratios of the forbidden (f), intercombination (i), and recombination (r) lines of the Heα triplets of N VI, O VII, and Ne IX measured by Itoh et al. in the XMM-Newton Reflection Grating Spectrometer spectrum and those of O VII, Ne IX, Mg XI, and Si XIII in the Chandra HETG spectrum, either the electron density of the plasma increases with temperature by over three orders of magnitude, from n e ∼ 6 x 10 10 cm -3 for N VI [log T(K) ∼ 6] to n e ∼ 1 x 10 14 cm -3 for Si XIII [log T(K) ∼ 7], and/or the plasma is significantly affected by photoexcitation. Third, the radial velocity of the X-ray emission lines varies on the white dwarf spin phase, with two oscillations per spin cycle and an amplitude K ∼ 160 km s -1 . These results appear to be inconsistent with the recent models of Itoh et al., Ikhsanov, and

  7. Near Infrared High Resolution Spectroscopy and Spectro-astrometry of Gas in Disks around Herbig Ae/Be Stars

    OpenAIRE

    Brittain, Sean D.; Najita, Joan R.; Carr, John S.

    2015-01-01

    In this review, we describe how high resolution near infrared spectroscopy and spectro-astrometry have been used to study the disks around Herbig~Ae/Be stars. We show how these tools can be used to identify signposts of planet formation and elucidate the mechanism by which Herbig Ae/Be stars accrete. We also highlight some of the artifacts that can complicate the interpretation of spectro-astrometric measurements and discuss best practices for mitigating these effects. We conclude with a brie...

  8. ICP27-dependent resistance of herpes simplex virus type 1 to leptomycin B is associated with enhanced nuclear localization of ICP4 and ICP0

    International Nuclear Information System (INIS)

    Lengyel, Joy; Strain, Anna K.; Perkins, Keith D.; Rice, Stephen A.

    2006-01-01

    It was previously shown that herpes simplex virus type 1 (HSV-1) is sensitive to leptomycin B (LMB), an inhibitor of nuclear export factor CRM1, and that a single methionine to threonine change at residue 50 (M50T) of viral immediate-early (IE) protein ICP27 can confer LMB resistance. In this work, we show that deletion of residues 21-63 from ICP27 can also confer LMB resistance. We further show that neither the M50T mutation nor the presence of LMB affects the nuclear shuttling activity of ICP27, suggesting that another function of ICP27 determines LMB resistance. A possible clue to this function emerged when it was discovered that LMB treatment of HSV-1-infected cells dramatically enhances the cytoplasmic accumulation of two other IE proteins, ICP0 and ICP4. This effect is completely dependent on ICP27 and is reversed in cells infected with LMB-resistant mutants. Moreover, LMB-resistant mutations in ICP27 enhance the nuclear localization of ICP0 and ICP4 even in the absence of LMB, and this effect can be discerned in transfected cells. Thus, the same amino (N)-terminal region of ICP27 that determines sensitivity to LMB also enhances ICP27's previously documented ability to promote the cytoplasmic accumulation of ICP4 and ICP0. We speculate that ICP27's effects on ICP4 and ICP0 may contribute to HSV-1 LMB sensitivity

  9. Using ICP and micro-PIXE to investigate possible differences in the mineral composition of genetically modified versus wild-type sorghum grain

    Science.gov (United States)

    Ndimba, R.; Cloete, K.; Mehlo, L.; Kossmann, J.; Mtshali, C.; Pineda-Vargas, C.

    2017-08-01

    In the present study, possible differences in the mineral composition of transgenic versus non-transgenic sorghum grains were investigated using inductively coupled atomic emission spectroscopy (ICP-AES); and, in-tissue elemental mapping by micro Proton-Induced X-ray Emission (micro-PIXE) analysis. ICP AES was used to analyse the bulk mineral content of the wholegrain flour derived from each genotype; whilst micro-PIXE was used to interrogate localised differences in mineral composition specific to certain areas of the grain, such as the bran layer and the central endosperm tissue. According to the results obtained, no significant difference in the average Fe, Zn or Ca content was found to differentiate the transgenic from the wild-type grain using ICP-AES. However, using micro-PIXE, a significant reduction in zinc could be detected in the bran layer of the transgenic grains relative to wild-type. Although it is difficult to draw firm conclusions, as a result of the small sample size used in this study, micro-PIXE has nonetheless proven itself as a useful technique for highlighting the possibility that there may be reduced levels of zinc accumulation in the bran layer of the transgenic grains. Given that the genetic modification targets proteins that are highly concentrated in certain parts of the bran tissue, it seems plausible that the reduced levels of zinc may be an unintended consequence of the silencing of kafirin proteins. Although no immediate health or nutritional concerns emerge from this preliminary finding, it is noted that zinc plays an important biological role within this part of the grain as a structural stabiliser and antioxidant factor. Further study is therefore needed to assess more definitively the extent of the apparent localised reduction in zinc in the transgenic grains and how this may affect other important grain quality characteristics.

  10. Comparison of digestion procedures used for the determination of boron in biological tissues by ICP-AES [inductively-coupled, plasma-atomic emission spectroscopy

    International Nuclear Information System (INIS)

    Bauer, W.F.; Miller, D.L.; Steele, S.M.

    1988-01-01

    A study was designed to identify the most accurate and reliable procedures for the digestion of biological tissues prior to the determination of boron by inductively-coupled, plasma-atomic emission spectroscopy (ICP-AES). The four procedures used in this study were an acid bomb digestion and digestions performed in test tubes using perchloric acid and hydrogen peroxide, nitric acid and hydrogen peroxide, and nitric acid alone. Digestions using nitric acid and hydrogen peroxide and nitric acid alone were performed in a manner analogous to the perchloric acid/hydrogen peroxide procedure. The tissues used in the study were from dogs that had been administered a boron compound (Na 2 B 12 H 11 SH) and included two brain tissues, a liver and a tongue. These tissues were selected in order to eliminate results that may be due to surface spiking only. None of the test tube procedures were successful in completely dissolving the samples, as was evidenced by residual color and a coagulated precipitate. The amount of precipitate was much larger for the brain tissues in all cases. The acid bomb digestion and the perchloric acid/hydrogen peroxide procedures gave comparable boron concentrations for all of the tissues in this study. 2 refs., 1 tab

  11. Ophthalmodynamometry for ICP prediction and pilot test on Mt. Everest.

    Science.gov (United States)

    Querfurth, Henry W; Lieberman, Philip; Arms, Steve; Mundell, Steve; Bennett, Michael; van Horne, Craig

    2010-11-01

    A recent development in non-invasive techniques to predict intracranial pressure (ICP) termed venous ophthalmodynamometry (vODM) has made measurements in absolute units possible. However, there has been little progress to show utility in the clinic or field. One important application would be to predict changes in actual ICP during adaptive responses to physiologic stress such as hypoxia. A causal relationship between raised intracranial pressure and acute mountain sickness (AMS) is suspected. Several MRI studies report that modest physiologic increases in cerebral volume, from swelling, normally accompany subacute ascent to simulated high altitudes. 1) Validate and calibrate an advanced, portable vODM instrument on intensive patients with raised intracranial pressure and 2) make pilot, non-invasive ICP estimations of normal subjects at increasing altitudes. The vODM was calibrated against actual ICP in 12 neurosurgical patients, most affected with acute hydrocephalus and monitored using ventriculostomy/pressure transducers. The operator was blinded to the transducer read-out. A clinical field test was then conducted on a variable data set of 42 volunteer trekkers and climbers scaling Mt. Everest, Nepal. Mean ICPs were estimated at several altitudes on the ascent both across and within subjects. Portable vODM measurements increased directly and linearly with ICP resulting in good predictability (r = 0.85). We also found that estimated ICP increases normally with altitude (10 ± 3 mm Hg; sea level to 20 ± 2 mm Hg; 6553 m) and that AMS symptoms did not correlate with raised ICP. vODM technology has potential to reliably estimate absolute ICP and is portable. Physiologic increases in ICP and mild-mod AMS are separate responses to high altitude, possibly reflecting swelling and vasoactive instability, respectively.

  12. Determination of elements in concrete of a nuclear accelerator to dismantle, by instrumental neutron activation analysis, ICPMS and ICPAES

    International Nuclear Information System (INIS)

    Gaudry, A.; Bertho, X.; Piccot, D.; Fougeron, C.

    1998-01-01

    The distribution of radionuclides and their radioactivity in irradiated waste concrete are modelled using the characteristics of nuclear particle fluxes integrated all during the life-time of the installation, chemical composition of the material, and activation parameters of nuclear reactions produced by particles and secondary neutrons on elements. This paper describes the techniques used for determining the chemical composition of trace elements radioactivated by neutrons and particles, but also the major elements which act upon the neutron penetration into the depth of the concrete. Major elements were determined using mainly, Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) for Si, Al, Fe, Mn, Mg, Ca, Na, K, Ti, P and Instrumental Neutron Activation Analysis (INAA) for Al, Mn, Fe, Mg, Ca, Ba, Na, K, and other specific methods for C, O, S, and H. Trace elements were also determined using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and INAA. Forty five elements were determined. When present, solid iron was separated by a magnetic bar after previous breaking of the concrete. The concrete was powdered to a granulometry of less than 0.5 mm for INAA and homogenized. Iron was determined separately by INAA. For the determinations by ICP-AES and ICP-MS, powders were previously fused by means of LiBO 2 , then dissolved in dilute HNO 3 before analysis. A comparison between the results obtained, on the one hand, by ICP-AES and INAA, on the second hand, by ICP-MS and INAA revealed generally a very good agreement, making consistent analytical results

  13. Specific activity measurement of 64Cu: A comparison of methods

    International Nuclear Information System (INIS)

    Mastren, Tara; Guthrie, James; Eisenbeis, Paul; Voller, Tom; Mebrahtu, Efrem; Robertson, J. David; Lapi, Suzanne E.

    2014-01-01

    Effective specific activity of 64 Cu (amount of radioactivity per µmol metal) is important in order to determine purity of a particular 64 Cu lot and to assist in optimization of the purification process. Metal impurities can affect effective specific activity and therefore it is important to have a simple method that can measure trace amounts of metals. This work shows that ion chromatography (IC) yields similar results to ICP mass spectrometry for copper, nickel and iron contaminants in 64 Cu production solutions. - Highlights: • Comparison of TETA titration, ICP mass spectrometry, and ion chromatography to measure specific activity. • Validates ion chromatography by using ICP mass spectrometry as the “gold standard”. • Shows different types and amounts of metal impurities present in 64 Cu

  14. Auroral Electrojet (AE, AL, AO, AU) - A Global Measure of Auroral Zone Magnetic Activity

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The AE index is derived from geomagnetic variations in the horizontal component observed at selected (10-13) observatories along the auroral zone in the northern...

  15. Ophthalmodynamometry for ICP prediction and pilot test on Mt. Everest

    Directory of Open Access Journals (Sweden)

    Bennett Michael

    2010-11-01

    Full Text Available Abstract Background A recent development in non-invasive techniques to predict intracranial pressure (ICP termed venous ophthalmodynamometry (vODM has made measurements in absolute units possible. However, there has been little progress to show utility in the clinic or field. One important application would be to predict changes in actual ICP during adaptive responses to physiologic stress such as hypoxia. A causal relationship between raised intracranial pressure and acute mountain sickness (AMS is suspected. Several MRI studies report that modest physiologic increases in cerebral volume, from swelling, normally accompany subacute ascent to simulated high altitudes. Objectives 1 Validate and calibrate an advanced, portable vODM instrument on intensive patients with raised intracranial pressure and 2 make pilot, non-invasive ICP estimations of normal subjects at increasing altitudes. Methods The vODM was calibrated against actual ICP in 12 neurosurgical patients, most affected with acute hydrocephalus and monitored using ventriculostomy/pressure transducers. The operator was blinded to the transducer read-out. A clinical field test was then conducted on a variable data set of 42 volunteer trekkers and climbers scaling Mt. Everest, Nepal. Mean ICPs were estimated at several altitudes on the ascent both across and within subjects. Results Portable vODM measurements increased directly and linearly with ICP resulting in good predictability (r = 0.85. We also found that estimated ICP increases normally with altitude (10 ± 3 mm Hg; sea level to 20 ± 2 mm Hg; 6553 m and that AMS symptoms did not correlate with raised ICP. Conclusion vODM technology has potential to reliably estimate absolute ICP and is portable. Physiologic increases in ICP and mild-mod AMS are separate responses to high altitude, possibly reflecting swelling and vasoactive instability, respectively.

  16. Metal ion transport quantified by ICP-MS in intact cells

    Science.gov (United States)

    Figueroa, Julio A. Landero; Stiner, Cory A.; Radzyukevich, Tatiana L.; Heiny, Judith A.

    2016-01-01

    The use of ICP-MS to measure metal ion content in biological tissues offers a highly sensitive means to study metal-dependent physiological processes. Here we describe the application of ICP-MS to measure membrane transport of Rb and K ions by the Na,K-ATPase in mouse skeletal muscles and human red blood cells. The ICP-MS method provides greater precision and statistical power than possible with conventional tracer flux methods. The method is widely applicable to studies of other metal ion transporters and metal-dependent processes in a range of cell types and conditions. PMID:26838181

  17. Indigenous development of a glove box for ICP-OES

    International Nuclear Information System (INIS)

    Khan, A.M.; Anwar, M.K.; Bangash, M.A.

    2011-01-01

    Chemical analysis involving nuclear materials are bound to be carried out in safety enclosures like glove box, fume hood etc. whereas chemical analysis which produce mist or vapors of these materials like Atomic absorption Spectrometry, Flame photometry and ICP-AE spectrometry etc. must be performed in a glove box with HEPA filters on exhaust. These instruments with glove box adaptation are rare and impossible to import for our country. An ICP-OES, model Integra-XL of GBC-Australia was purchased in 2008 for chemical analysis of similar materials. As usual it was manufactured to operate in open atmosphere. The required analytical work could not be done in open atmosphere due to active nature of the samples. Therefore modification and glove box (GB) adaptation was required. Although large in size yet difficult to adapt for GB, the instrument had to be modified to a large extent as only sample handling part of the instrument had to placed inside GB, leaving rest of the instrument available for later repair/maintenance work. Different options were considered for modification keeping in mind the isolation and negative pressure inside the GB and maintaining the integrity of the instrument. One of such option was finalized which involved shifting the optic tank etc. A no of isolation gadgets were designed and fabricated locally. This indigenization has saved some handsome amount of foreign exchange. (Author)

  18. Application of AE to evaluate deterioration of prt and harbor structures

    International Nuclear Information System (INIS)

    Matsuyama, Kimitoshi; Ishibashi, Akichika; Fujiwara, Tetsuro; Kanemoto, Yasuhiro; Hamada, Shigenori; Ohtsu, Masayasu

    1997-01-01

    The degree of concrete deterioration is normally evaluated by uniaxial compression tests of core samples taken from existing concrete structures. The uniaxial compression test can give details on concrete strength, elastic modulus and so forth. By using AE(acoustic emission) technique with uniaxial compression tests, we can get more useful information on interior failures of the core sample. The observation of AE activity was conducted during uniaxial compression tests of concrete specimens and samples. The specimens were cast with 5, 10, 15 and 20% air content. The samples were taken from 2 harbor sites in Japan. Generating behavior of AE was studied quantitatively on the basis of rate process theory. Distribution of pores in the concrete could be measured by the porosimeter. The relation between AE activity in the uniaxial compression test of core samples and concrete property is clarified.

  19. Association of glass fragments by their trace elemental content using ICP-MS and LA-ICP-MS in the analysis scheme

    Science.gov (United States)

    Almirall, Jose R.; Montero, Shirly; Furton, Kenneth G.

    2002-08-01

    The importance of glass as evidence of association between a crime event and a suspect has been recognized for some time. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. The physical and chemical properties of glass can be used to differentiate between possible sources and as evidence of association between two fragments of glass thought to originate from the same source. Refractive index (RI) comparisons have been used for this purpose but due to the improved control over glass manufacturing processes, RI values often cannot differentiate glasses, even if the glass originates from different sources. Elemental analysis methods such as NAA, XRF, ICP-AES, and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) have also been used for the comparison of trace elemental compositions and these techniques have been shown to provide an improvement in the discrimination of glass fragments over RI comparisons alone. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The methodology for solution analysis (digestion procedure) and solid sample analysis (laser ablation) of glass is reported and the analytical results are compared. An isotope dilution method is also reported as a high precision technique for elemental analysis of glass fragments. The optimum sampling parameters for laser ablation, for semi-quantitative analysis and element ratio comparisons are also presented. Finally, the results of a case involving the breaking of 15 vehicle windows in an airport parking lot and the association of a suspect to the breakings by the glass fragments found on his person are also presented.

  20. Comparison of two brain tumor-localizing MRI agent. GD-BOPTA and GD-DTPA. MRI and ICP study of rat brain tumor model

    International Nuclear Information System (INIS)

    Zhang, T.; Matsumura, A.; Yamamoto, T.; Yoshida, F.; Nose, T.

    2000-01-01

    In this study, we compared the behavior of Gd-BOPTA as a brain tumor selective contrast agent with Gd-DTPA in a common dose of 0.1 mmol/kg. We performed a MRI study using those two agent as contrast material, and we measured tissue Gd-concentrations by ICP-AES. As a result, Gd-BOPTA showed a better MRI enhancement in brain tumor. ICP showed significantly greater uptake of Gd-BOPTA in tumor samples, at all time course peaked at 5 minutes after administration, Gd being retained for a longer time in brain tumor till 2 hours, without rapid elimination as Gd-DTPA. We conclude that Gd-BOPTA is a new useful contrast material for MR imaging in brain tumor and an effective absorption agent for neutron capture therapy for further research. (author)

  1. Measuring the BNF of Soybean Using 15N-Labelled Urea with Different Atom Excess (A.E. Content

    Directory of Open Access Journals (Sweden)

    A. Citraresmini

    2012-12-01

    Full Text Available The soybean is a legume which has an ability to supply its major nitrogen need by the biological nitrogen fixation (BNF process. This process is made possible by nodules formed in their roots, colonized by Rhizobium sp.bacteria. An accurate estimation of N gained by BNF is necessary to predict the increase or decrease of chemical fertilizer-N requirements to increase soybean production. Among several methods, the 15N method was used to estimate the ability of legumes to perform BNF. The study involved soybean var. Willis (W and a completely non-BNF soybean var. CV, which is termed as a standard crop. The standard crop is non-nodulated soybean, but it has the same main physiological traits with var. Willis. The aim of this study was to determine whether15N-labelled fertilizer with different %a.e. given to nodulated and non-nodulated soybean would not be of significant consequences for the calculation of N-BNF of W. The treatments applied were different rates of urea (20 kg N/ha and 100 kg N/ha combined with different atom excess percentages (%a.e.15N (2% and 10%. Thus, the combination of treatments were as follows:(1 W-ll (20 kg N; 2% a.e; (2 CV-hl (100 kg N; 2% a.e; (3 W-lh (20 kg N; 10% a.e; (4 CV-hh (100 kg N; 10% a.e; (5 CV-ll (20 kg N; 2% a.e; (6 W-hl (100 kg N; 2% a.e; (7 CV-lh (20 kg N; 10% a.e; (8 W-hh (100 kg N; 10% a.e. The result of the experiment showed that a high %a.e. with a low rate of 15N and a low %a.e. with a high rate of N should be used to study the %N-BNF of nodulated plants.

  2. The use of ICP-MS and LA-ICP-MS techniques for uranium analysis in real-life swipe samples for safeguards purposes

    Energy Technology Data Exchange (ETDEWEB)

    Pestana, Rafael C.B.; Sarkis, Jorge E.S.; Carvalho, Elita F.U., E-mail: rcbpestana@gmail.com, E-mail: jesarkis@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Abreu Junior, Cassio H. [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)

    2013-07-01

    Environmental swipe sampling for safeguards purposes is a powerful tool to detect undeclared materials and activities, and has been used by the International Atomic Energy Agency since 1997. This work describes the utilization of the inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for determining uranium isotopic ratios in a real-life swipe samples collected in a conversion plant at IPEN/CNEN, Brazil. Uncertainties were estimated by following the International Organization for Standardization - Guide to the Expression of Uncertainties in Measurement (ISO GUM), with a confidence level of 95%. The major uncertainties percentage for n({sup 235}U)/n({sup 238}U) ratio for ICP-MS was 3% and for LA-ICP-MS was 30% The values of uranium isotopic ratios obtained for each technique demonstrate the viability of these analytical techniques as an alternative tool for uranium analysis in swipe samples for safeguards purposes. (author)

  3. The use of ICP-MS and LA-ICP-MS techniques for uranium analysis in real-life swipe samples for safeguards purposes

    International Nuclear Information System (INIS)

    Pestana, Rafael C.B.; Sarkis, Jorge E.S.; Carvalho, Elita F.U.; Abreu Junior, Cassio H.

    2013-01-01

    Environmental swipe sampling for safeguards purposes is a powerful tool to detect undeclared materials and activities, and has been used by the International Atomic Energy Agency since 1997. This work describes the utilization of the inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for determining uranium isotopic ratios in a real-life swipe samples collected in a conversion plant at IPEN/CNEN, Brazil. Uncertainties were estimated by following the International Organization for Standardization - Guide to the Expression of Uncertainties in Measurement (ISO GUM), with a confidence level of 95%. The major uncertainties percentage for n( 235 U)/n( 238 U) ratio for ICP-MS was 3% and for LA-ICP-MS was 30% The values of uranium isotopic ratios obtained for each technique demonstrate the viability of these analytical techniques as an alternative tool for uranium analysis in swipe samples for safeguards purposes. (author)

  4. ICP magnetic sector multiple collector mass spectrometry and the precise measurement of isotopic compositions using nebulization of solutions and laser ablation of solids

    International Nuclear Information System (INIS)

    Halliday, A.N.; Lee, D-C.; Christensen, J.N.; Yi, W.; Hall, C.M.; Jones, C.E.; Teagle, D.A.H.; Freedman, P.A.

    1996-01-01

    Inductively-coupled plasma (ICP) sources offer considerable advantages over thermal sources because the high ionization efficiency facilitates measurements of relatively high sensitivity for elements such as Hf or Sn, which can be difficult to measure precisely with thermal ionization mass spectrometry (TIMS). The mass discrimination (bias) is larger than for TIMS, favours the heavier ions, and decreases in magnitude with increasing mass. However, in contrast to TIMS, this discrimination is largely independent of the chemical or physical properties of the element or the duration of the analysis. This has been demonstrated to high precision with a double focussing multiple collector magnetic sector mass spectrometer with an ICP source. The principle of this instrument is briefly described. The potential of the instrument for high precision isotopic measurements of a very broad range of elements, using solution aspiration or laser ablation, is indicated. 15 refs

  5. Spatial patterns of high Aedes aegypti oviposition activity in northwestern Argentina.

    Directory of Open Access Journals (Sweden)

    Elizabet Lilia Estallo

    Full Text Available BACKGROUND: In Argentina, dengue has affected mainly the Northern provinces, including Salta. The objective of this study was to analyze the spatial patterns of high Aedes aegypti oviposition activity in San Ramón de la Nueva Orán, northwestern Argentina. The location of clusters as hot spot areas should help control programs to identify priority areas and allocate their resources more effectively. METHODOLOGY: Oviposition activity was detected in Orán City (Salta province using ovitraps, weekly replaced (October 2005-2007. Spatial autocorrelation was measured with Moran's Index and depicted through cluster maps to identify hot spots. Total egg numbers were spatially interpolated and a classified map with Ae. aegypti high oviposition activity areas was performed. Potential breeding and resting (PBR sites were geo-referenced. A logistic regression analysis of interpolated egg numbers and PBR location was performed to generate a predictive mapping of mosquito oviposition activity. PRINCIPAL FINDINGS: Both cluster maps and predictive map were consistent, identifying in central and southern areas of the city high Ae. aegypti oviposition activity. A logistic regression model was successfully developed to predict Ae. aegypti oviposition activity based on distance to PBR sites, with tire dumps having the strongest association with mosquito oviposition activity. A predictive map reflecting probability of oviposition activity was produced. The predictive map delimitated an area of maximum probability of Ae. aegypti oviposition activity in the south of Orán city where tire dumps predominate. The overall fit of the model was acceptable (ROC=0.77, obtaining 99% of sensitivity and 75.29% of specificity. CONCLUSIONS: Distance to tire dumps is inversely associated with high mosquito activity, allowing us to identify hot spots. These methodologies are useful for prevention, surveillance, and control of tropical vector borne diseases and might assist

  6. Determination of iron in highly-saline matrices by FIA-ICP-MS

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    Analysis of iron by inductively-coupled-plasma mass-spectrometry (ICP-MS) may be significantly improved by applying a protocol of flow-injection analysis. The iron species of the sample was preconcentrated by an ammonia buffer at pH = 9.2 on a filterless nylon-knotted reactor, and the adsorbed...... species were subsequently eluted by hydrochloric acid and analysed by ICP-MS. During the FIA step of preconcentration, a high degree of salinity did not influence the adsorption mechanism of iron, which may be related to formation of iron-hydroxide complexes at the sites of amide moieties of the nylon...

  7. Determination of 241Am in sediments by isotope dilution high resolution inductively coupled plasma mass spectrometry (ID HR ICP-MS).

    Science.gov (United States)

    Agarande, M; Benzoubir, S; Bouisset, P; Calmet, D

    2001-08-01

    Trace levels (pg kg(-1)) of 241Am in sediments were determined by isotope dilution high resolution inductively coupled plasma mass spectrometry (ID HR ICP-MS) using a microconcentric nebulizer. 241Am was isolated from major elements like Ca and Fe by different selective precipitations. In further steps. Am was first separated from other transuranic elements and purified by anion exchange and extraction chromatography prior to the mass spectrometric measurements. The ID HR ICP-MS results are compared with isotope dilution alpha spectrometry.

  8. Monitoring radionuclides in marine organisms

    International Nuclear Information System (INIS)

    Ishii, T.; Matsuba, M.; Kurosawa, M.; Koyanagi, T.

    1990-01-01

    Concentration of stable elements corresponding to important radionuclides was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS) for various marine organisms to find indicator organisms for environmental monitoring. Both analytical techniques indicated linearity over a range of concentrations covering 2-4 orders of magnitude. Detection limits of elements by ICP-MS were 10 or 100 times higher than those of ICP-AES, although the precision and accuracy of ICP-MS was slightly inferior to that of ICP-AES. For quantitative analysis of elements with medium mass numbers (chromium, manganese, iron, nickel, copper, zinc, etc.), matrix interferences in ICP-MS were caused mainly by overlaps of spectra from coexisting elements in biological samples. The presence of background ions from atmosphere, water, and argon plasma interfered with determination of some isotopes. Most elements of high mass number could not be determined by ICP-AES because of its poor detection limits, whereas ICP-MS indicated high sensitivity and low background for elements of interest. We used ICP-MS analysis to determine the specific accumulation of certain elements in organs or tissues of 30 marine organisms

  9. ICP-MS measurement of natural radioactivity at LNGS

    Science.gov (United States)

    Nisi, S.; Copia, L.; Dafinei, I.; di Vacri, M. L.

    2017-10-01

    Rare events search experiments, like those dedicated to the direct evidence of dark matter or neutrinoless double beta decay, are among the most exciting challenges of modern physics. The sensitivity of such experiments is driven by the background, which depends substantially on the radiopurity of the materials used for the experimental apparatus. Cutting edge measurement techniques are needed for a fast, sensitive and efficient screening of these materials and the certification of their production. Trace element measurements of high sensitivity and quick execution are mandatory also in other fields like tracing the geographical origin of food, temporal and geographical assignment of cultural heritage or monitoring environmental radioactivity. This work is an overview of the inorganic mass spectrometry facility available at Gran Sasso National Laboratory (LNGS) for radiopure material screening and is especially focused on its ICP-MS instrumentation. Analytical methods developed to achieve lowest detection limits in different types of matrix, like metals, polymers, crystals and composite materials, are also indicated. Detection limits of 10-18gg-1 for 226Ra, 10-14gg-1 for U and Th and 10-12gg-1 for K are attained through dedicated operation conditions of the instrumentation. Details are given on the results obtained for different experiments ongoing or under construction at LNGS.

  10. Modification of working parameters for routine determination of trace elemental impurities in PuO2 samples by direct current arc-AES

    International Nuclear Information System (INIS)

    Pant, D.K.; Phadke, M.P.; Dapolikar, T.T.; Kapur, H.N.; Kumar, Rajendra; Dubey, K.

    2015-01-01

    In the present work we have altered the parameters of routine method to determine the trace elemental impurities in PuO 2 samples using DC arc source optically coupled with CCD based spectrometer system. The method is basically a fractional distillation technique using DC arc source, involving ignition, dilution of the sample with U 3 O 8 containing carrier mixture, arcing of the sample/standard mixture in DC arc and measurement of analyte signals by spectrometer system. In all fifteen elemental impurities including Boron and Cadmium were determined. Detection limits are comparable with ICP-AES method. (author)

  11. The measurement of metallic uranium solubility in lithium chloride molten salt

    International Nuclear Information System (INIS)

    Park, K. K.; Choi, I. K.; Yeon, J. W.; Choi, K. S.; Park, Y. J.

    2002-01-01

    For the purpose of more precise solubility measurement of metallic uranium in lithium chloride melt, the effect of lithium chloride on uranium determination and and the change of oxidation state of metallic uranium in the media were investigated. Uranium of higher than 10 μg/g could be directly determined by ICP-AES. In the case of the lower concentration, the separation and concentration of uranium by anion exchanger was followed by ICP-AES, thereby extending the measurable concentration to 0.1 μg/g. The effects of lithium oxide, uranium oxides(UO 2 or U 3 O 8 ) and metallic lithium on the solubility of metallic uranium were individually investigated in glassy carbon or stainless steel crucibles under argon gas atmosphere. Since metallic uranium is oxidized to uranium(III) in the absence of metallic lithium, causing an increase in the solubility, metallic lithium as reducing agent should be present in the reaction media to obtain the more precise solubility. The metallic uranium solubilities measured at 660 and 690 .deg. C were both lower than 10 μg/g

  12. [Determination of total mass and morphology analysis of heavy metal in soil with potassium biphthalate-sodium hydroxide by ICP-AES].

    Science.gov (United States)

    Qu, Jiao; Yuan, Xing; Cong, Qiao; Wang, Shuang

    2008-11-01

    Blank soil was used as quality controlling samples, soil sample dealt by potassium biphthalate-sodium hydroxide buffer solution was used as check sample, mixed acid HNO3-HF-HClO4 was chosen to nitrify soil samples, and plasma emission spectrometer (ICP-AES) was used as detecting method. The authors determined the total metal mass of Mo, Pb, As, Hg, Cr, Cd, Zn, Cu and Ni in the extracted and dealt soil samples, and determined the mass of Mo, Pb, As, Hg, Cr, Cd, Zn, Cu and Ni in the three chemical morphologies, including acid extractable morphology, oxide associated morphology, and organics associated modality. The experimental results indicated that the different pH of potassium biphthalate-sodium hydroxide buffer solution had obvious influence on the total mass of heavy metal and morphology transformation. Except for metal element Pb and Zn, the addition of different pH potassium dihydrogen phosphate-sodium hydroxide buffer solution could accelerate the soil samples nitrification and the total mass determination of heavy metal in the soil samples. The potassium biphthalate-sodium hydroxide buffer solution could facilitate the acid extractable morphology of Cr, Cu, Hg and Pb, oxidation associated morphology of As, Hg, Pb and Zn and the organic associated morphology transforming of As and Hg. At pH 5.8, the maximum acid extractable morphology contents of Cu and Hg were 2.180 and 0.632 mg x kg(-1), respectively; at pH 6.2, the maximal oxidation associated morphology content of Pb could achieve 27.792 mg x kg(-1); at pH 6.0, the maximum organic associated morphology content of heavy metal Hg was 4.715 mg x kg(-1).

  13. A Novel Recommendation To AES Limitation

    Directory of Open Access Journals (Sweden)

    Falguni Patel

    2017-07-01

    Full Text Available Among all available conventional encryption algorithms the AES Advanced Encryption Standard is the most secured and highly used algorithm. AES algorithm is widely used by variety of applications like Archive and Compression tools File Encryption Encryption File System Disk Partition Encryption Networking Signal Protocol among others. This paper highlights the Brute Force attack and Cryptanalysis attack on AES Algorithm. This paper also discusses about a novel recommendation of a combination model of AES Algorithm and Random-X Cipher.

  14. Impact of and correction for instrument sensitivity drift on nanoparticle size measurements by single-particle ICP-MS

    Science.gov (United States)

    El Hadri, Hind; Petersen, Elijah J.; Winchester, Michael R.

    2016-01-01

    The effect of ICP-MS instrument sensitivity drift on the accuracy of NP size measurements using single particle (sp)ICP-MS is investigated. Theoretical modeling and experimental measurements of the impact of instrument sensitivity drift are in agreement and indicate that drift can impact the measured size of spherical NPs by up to 25 %. Given this substantial bias in the measured size, a method was developed using an internal standard to correct for the impact of drift and was shown to accurately correct for a decrease in instrument sensitivity of up to 50 % for 30 nm and 60 nm gold nanoparticles. PMID:26894759

  15. Electron stimulated carbon adsorption in ultra high vacuum monitored by Auger Electron Spectroscopy (AES)

    CERN Document Server

    Scheuerlein, C

    2001-01-01

    Electron stimulated carbon adsorption at room temperature (RT) has been studied in the context of radiation induced surface modifications in the vacuum system of particle accelerators. The stimulated carbon adsorption was monitored by AES during continuous irradiation by 2.5 keV electrons and simultaneous exposure of the sample surface to CO, CO2 or CH4. The amount of adsorbed carbon was estimated by measuring the carbon Auger peak intensity as a function of the electron irradiation time. Investigated substrate materials are technical OFE copper and TiZrV non-evaporable getter (NEG) thin film coatings, which are saturated either in air or by CO exposure inside the Auger electron spectrometer. On the copper substrate electron induced carbon adsorption from gas phase CO and CO2 is below the detection limit of AES. During electron irradiation of the non-activated TiZrV getter thin films, electron stimulated carbon adsorption from gas phase molecules is detected when either CO or CO2 is injected, whereas the CH4 ...

  16. ICP-MS measurement of silver diffusion coefficient in graphite IG-110 between 1048K and 1284K

    Science.gov (United States)

    Carter, L. M.; Seelig, J. D.; Brockman, J. D.; Robertson, J. D.; Loyalka, S. K.

    2018-01-01

    Silver-110m has been shown to permeate intact silicon carbide and pyrolytic carbon coating layers of the TRISO fuel particles during normal High Temperature Gas-Cooled Reactor (HTGR) operational conditions. The diffusion coefficients for silver in graphite IG-110 measured using a release method designed to simulate HTGR conditions of high temperature and flowing helium in the temperature range 1048-1253 K are reported. The measurements were made using spheres milled from IG-110 graphite that were infused with silver using a pressure vessel technique. The Ag diffusion was measured using a time release technique with an ICP-MS instrument for detection. The results of this work are:

  17. ICP Mass and Optical Emission Spectrometry of Ore Samples Containing Rare Earth Elements

    International Nuclear Information System (INIS)

    Mohammed, A.E.W.M.

    2013-01-01

    Inductively Coupled Plasma Optical Emission and Mass Spectrometry (ICP-OES and ICPMS) are widely accepted as a rapid and sensitive techniques for Rare Earth Elements (REEs) analysis of geological samples. However, the achievable accuracy of these techniques are seriously limited by the problem of matrix interferences. In this study, matrix effects in ICP-AES were addressed using two approaches. In the first approach, the mechanisms of matrix interferences and analyte excitation were elucidated fundamentally. First, matrix effects from a comprehensive list of thirty-nine elements were investigated. It was confirmed that matrix elements with low second (instead of the widely reported first) ionization potentials (IP) produce a stronger matrix effect in all cases. Another critical parameter defining the severity of the matrix effect was found to be the availability of low-lying energy levels in the doubly charged matrix ion. Penning ionization followed by ion electron recombination through successive cycles is proposed as the mechanism for the more severe matrix effects caused by low second-IP matrices. In the second approach ICP-OES and ICP-MS are applied in this study for the analysis of Rare Earth Elements of two selected standard reference samples namely AGV-2 and BCR-2 beside a fluorspar geological sample (G-9 sample). Effective procedures are developed to avoid the spectral interference from matrix elements by using ion exchange resin Amberlite IR-120 before determination of REEs using ICP-OES and ICPMS. The potential of the method is evaluated by analysis of Certified Reference Materials (AGV-2 and BCR-2). Results obtained by ICP-MS show that experimental data are in agreement with the certified values and their values could be used as a quantitative data. The results obtained using ICP-OES were compared and discussed.

  18. A Rapid, Accurate, and Efficient Method to Map Heavy Metal-Contaminated Soils of Abandoned Mine Sites Using Converted Portable XRF Data and GIS

    Directory of Open Access Journals (Sweden)

    Jangwon Suh

    2016-12-01

    Full Text Available The use of portable X-ray fluorescence (PXRF and inductively coupled plasma atomic emission spectrometry (ICP-AES increases the rapidity and accuracy of soil contamination mapping, respectively. In practice, it is often necessary to repeat the soil contamination assessment and mapping procedure several times during soil management within a limited budget. In this study, we have developed a rapid, inexpensive, and accurate soil contamination mapping method using a PXRF data and geostatistical spatial interpolation. To obtain a large quantity of high quality data for interpolation, in situ PXRF data analyzed at 40 points were transformed to converted PXRF data using the correlation between PXRF and ICP-AES data. The method was applied to an abandoned mine site in Korea to generate a soil contamination map for copper and was validated for investigation speed and prediction accuracy. As a result, regions that required soil remediation were identified. Our method significantly shortened the time required for mapping compared to the conventional mapping method and provided copper concentration estimates with high accuracy similar to those measured by ICP-AES. Therefore, our method is an effective way of mapping soil contamination if we consistently construct a database based on the correlation between PXRF and ICP-AES data.

  19. Environmental radioactivity research on the Fukushima Dai-ichi Nuclear Power Plant accident by ICP-MS

    International Nuclear Information System (INIS)

    Ohno, Takeshi; Muramatsu, Yasuyuki

    2015-01-01

    Inductively coupled plasma (ICP) is characterized by high ionization efficiency for almost all elements. Recently, a triple quadrupole ICP-MS (ICP-MS/MS) has been applied to the measurements of isotope ratios for ultra-low level radioisotopes. The ICP-MS/MS features an additional quadrupole mass filter situated in front of the octopole reaction cell and quadrupole mass filter, which allows only the analyte ion to enter the cell by rejecting all the other ions. In this manuscript, we review recent studies on environmental radioactivity in Fukushima achieved by ICP-MS/MS techniques. (author)

  20. AE 941.

    Science.gov (United States)

    2004-01-01

    AE 941 [Arthrovas, Neoretna, Psovascar] is shark cartilage extract that inhibits angiogenesis. AE 941 acts by blocking the two main pathways that contribute to the process of angiogenesis, matrix metalloproteases and the vascular endothelial growth factor signalling pathway. When initial development of AE 941 was being conducted, AEterna assigned the various indications different trademarks. Neovastat was used for oncology, Psovascar was used for dermatology, Neoretna was used for ophthalmology and Arthrovas was used for rheumatology. However, it is unclear if these trademarks will be used in the future and AEterna appears to only be using the Neovastat trademark in its current publications regardless of the indication. AEterna Laboratories signed commercialisation agreements with Grupo Ferrer Internacional SA of Spain and Medac GmbH of Germany in February 2001. Under the terms of the agreement, AEterna has granted exclusive commercialisation and distribution rights to AE 941 in oncology to Grupo Ferrer Internacional for the Southern European countries of France, Belgium, Spain, Greece, Portugal and Italy. It also has rights in Central and South America. Medac GmbH will have marketing rights in Germany, the UK, Scandinavia, Switzerland, Austria, Ireland, the Netherlands and Eastern Europe. In October 2002, AEterna Laboratories announced that it had signed an agreement with Australian healthcare products and services company Mayne Group for marketing AE 941 (as Neovastat) in Australia, New Zealand, Canada and Mexico. In March 2003, AEterna Laboratories announced it has signed an agreement with Korean based LG Life Sciences Ltd for marketing AE 941 (as Neovastat) in South Korea. The agreement provides AEterna with upfront and milestone payments, as well as a return on manufacturing and sales of AE 941. AEterna Laboratories had granted Alcon Laboratories an exclusive worldwide licence for AE 941 for ophthalmic products. However, this licence has been terminated. In

  1. Recovery of spent high intensity neutron sources in Atalante Facility

    International Nuclear Information System (INIS)

    Bros, P.; Boyer Deslys, V.; Millet, A.; Solinhac, I.; Donnet, L.; Maillard, C.; Paillard, S.; Ranchoux, M.

    2005-01-01

    The Atalante facility is required by law to recover both neutron and gamma sources with activity levels exceeding 300 mCi. Most of the neutron sources consist of mixtures of alpha-emitters (238Pu, 239Pu, 241Am or 244Cm) and beryllium. Several processes now under consideration are based on routine chemical separation techniques (selective precipitation, extraction chromatography, ion exchange). The treatment produces an actinide oxide (which is used later for R and D studies) and solid beryllium nitrate, which is considered as a waste and transferred to a surface interim storage site if the overall activity of the package after 300 years is less than 50 MBq (ANDRA specifications). The Material Analysis and Metrology Laboratory of Atalante validate the residual alpha activity in the waste. The techniques used include alpha spectrometry and L-line X-ray fluorescence for alpha emitters, and plasma torch measurements (ICP-AES and ICP-MS) for beryllium analysis. Specific equipment for transport (B type cask), storage and treatment (hot shielded cells) are used for this activity. (Author)

  2. Sample preparation method for ICP-MS measurement of 99Tc in a large amount of environmental samples

    International Nuclear Information System (INIS)

    Kondo, M.; Seki, R.

    2002-01-01

    Sample preparation for measurement of 99 Tc in a large amount of soil and water samples by ICP-MS has been developed using 95m Tc as a yield tracer. This method is based on the conventional method for a small amount of soil samples using incineration, acid digestion, extraction chromatography (TEVA resin) and ICP-MS measurement. Preliminary concentration of Tc has been introduced by co-precipitation with ferric oxide. The matrix materials in a large amount of samples were more sufficiently removed with keeping the high recovery of Tc than previous method. The recovery of Tc was 70-80% for 100 g soil samples and 60-70% for 500 g of soil and 500 L of water samples. The detection limit of this method was evaluated as 0.054 mBq/kg in 500 g soil and 0.032 μBq/L in 500 L water. The determined value of 99 Tc in the IAEA-375 (soil sample collected near the Chernobyl Nuclear Reactor) was 0.25 ± 0.02 Bq/kg. (author)

  3. On the application of ICP-MS techniques for measuring uranium and plutonium: a Nordic inter-laboratory comparison exercise

    DEFF Research Database (Denmark)

    Qiao, Jixin; Lagerkvist, Petra; Rodushkin, Ilia

    2018-01-01

    Inductively coupled plasma mass spectrometry (ICP-MS) techniques are widely used for determination of long-lived radionuclides and their isotopic ratios in the nuclear fields. Uranium (U) and Pu (Pu) isotopes have been determined by many researchers with ICP-MS due to its relatively high sensitiv...

  4. Structural role of Cu in the soil active glasses

    Directory of Open Access Journals (Sweden)

    Irena Wacławska

    2012-06-01

    Full Text Available Glasses from the SiO2-P2O5-K2O-CaO-MgO-CuO system acting as slow release fertilizers were synthesized by the melt-quenching technique. Influence of copper addition on structure of the glasses was evaluated by XRD, SEM, FT-IR and Raman spectroscopy. Chemical activity of the glasses in 2 wt.% citric acid solutions was measured by ICP-AES method. It has been found that increasing content of phosphorous increased solubility of copper in the structure of the studied glasses which was the result of formation of P-O-Cu bonds.

  5. Inductively coupled plasma-atomic emission spectrometry: analytical assessment of the technique at the beginning of the 90's

    International Nuclear Information System (INIS)

    Sanz-Medel, A.

    1991-01-01

    The main application of the inductively coupled plasma (ICP) today is in atomic emission spectroscopy (AES), as an excitation spectrochemical source, although uses of an ICP for fluorescence as just an atomizer, and specially for mass spectrometry, as an ionization source, are rocketing in the last few years. Since its inception, only a quarter of a century ago, ICP-AES has rapidly evolved to one of the preferred routine analytical techniques for convenient determination of many elements with high speed, at low levels and in the most varied samples. Perhaps its comparatively high kinetic temperature (capable of atomizing virtually every compound of any sample), its high excitation and ionization temperatures, and its favourable spatial structure at the core of the ICP success. By now, the ICP-AES can be considered as having achieved maturity in that a huge amount of analytical problems can be tackled with this technique, while no major or fundamental changes have been adopted for several years. Despite this fact, important driving forces are still in operation to further improve the ICP-AES sensitivity, selectivity, precision, sample throughput, etc. Moreover, proposals to extend the scope of the technique to traditionally elusive fields (e.g. non-metals and organic compound analysis) are also appearing in the recent literature. In this paper the 'state of the art', the last developments and the expectations in trying to circumvent the limitations of the ICP-AES (on the light of literature data and personal experience) are reviewed. (author)

  6. High spatial resolution analysis of ferromanganese concretions by LA-ICP-MS†

    Directory of Open Access Journals (Sweden)

    Ingri Johan

    2002-06-01

    Full Text Available A procedure was developed for the determination of element distributions in cross-sections of ferromanganese concretions using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS. The effects of carrier flow rates, rf forward power, ablation energy, ablation spot size, repetition rate and number of shots per point on analyte intensity were studied. It is shown that different carrier gas flow rates are required in order to obtain maximum sensitivities for different groups of elements, thus complicating the optimisation of ICP parameters. On the contrary, LA parameters have very similar effects on almost all elements studied, thus providing a common optimum parameter set for the entire mass range. However, for selected LA parameters, the use of compromise conditions was necessary in order to compensate for relatively slow data acquisition by ICP-MS and maintain high spatial resolution without sacrificing the multielemental capabilities of the technique. Possible variations in ablation efficiency were corrected for mathematically using the sum of Fe and Mn intensities. Quantification by external calibration against matrix-matched standards was successfully used for more than 50 elements. These standards, in the form of pressed pellets (no binder, were prepared in-house using ferromanganese concentrates from a deep-sea nodule reference material as well as from shallow-marine concretions varying in size and having different proportions of three major phases: aluminosilicates, Fe- and Mn-oxyhydroxides. Element concentrations in each standard were determined by means of conventional solution nebulisation ICP-MS following acid digestion. Examples of selected inter-element correlations in distribution patterns along the cross-section of a concretion are given.

  7. Determination of 11 trace elements in U3O8 CRMs by ICP-AES

    International Nuclear Information System (INIS)

    Liu Husheng

    1994-01-01

    The TBP extractant-containing resin and extraction chromatography technique were used to separate 11 trace elements in U 3 O 8 CRMs. The sample was separated at a flow rate of 0.5 mL/min with 3 mol/L HNO 3 as medium. A model 975 ICP direct reading spectrometer was used to determine the trace elements of Ca, Cd, Cr, Cu, Fe, Mg, Mn, Mo, Ni, Pb and Sn in U 3 O 8 CRMs. The lowest quantitatively determinable concentration of impurities in U 3 O 8 CRMs are 0.02-1.6 μg/g. The RSD is less than 10%. The proposed method provides excellent and accurate analytical data for the U 3 O 8 samples prepared as certified reference materials (CRMs)

  8. Determination of trace elements in ceramic uranium dioxide pellets powders CRMs by ICP-AES

    International Nuclear Information System (INIS)

    Liu Husheng; Li Jun

    1997-01-01

    The 237-quaternary ammonium extraction resin chromatography is used to the separation of 6 trace elements in ceramic uranium dioxide pellets powders, which are used as certified reference materials (CRMs). The sample is dissolved in 6.5 mol/L HNO 3 and uranium is separated by chromatographic column. the 6 trace elements Al, Ba, Co, Ta, Ti and V contained in the elutriant are determined by using ICP directly reading spectrometer. For a 300 mg sample, the lowest determinable concentration of impurities in ceramic UO 2 pellets powders CRMs is (0.016-0.250) x 10 -6 . The relative standard deviation is less than 7.5%. The proposed method provides excellent and accurate analytical data for the ceramic UO 2 pellets powders samples (CRMs)

  9. Chemical analysis of rare earth elements

    International Nuclear Information System (INIS)

    Tsukahara, Ryoichi; Sakoh, Takefumi; Nagai, Iwao

    1994-01-01

    Recently attention has been paid to ICP-AES or ICP-MS, and the reports on the analysis of rare earth elements by utilizing these methods continue to increase. These reports have become to take about 30% of the reports on rare earth analysis, and this is because these methods are highly sensitive to rare earth elements, and also these methods have spread widely. In ICP-AES and ICP-MS, mostly solution samples are measured, therefore, solids must be made into solution. At the time of quantitatively determining the rare earth elements of low concentration, separation and concentration are necessary. Referring to the literatures reported partially in 1990 and from 1991 to 1993, the progress of ICP-AES and ICP-MS is reported. Rare earth oxides and the alloys containing rare earth elements are easily decomposed with acids, but the decomposition of rocks is difficult, and its method is discussed. The separation of the rare earth elements from others in geochemical samples, cation exchange process is frequently utilized. Also solvent extraction process has been studied. For the separation of rare earth elements mutually, chromatography is used. The spectral interference in spectral analysis was studied. The comparison of these methods with other methods is reported. (K.I)

  10. Development of AE monitoring system for journal bearing

    International Nuclear Information System (INIS)

    Yoon, Dong Jin; Kwon, Oh Yang; Chung, Min Hwa

    1994-01-01

    For the purpose of monitoring of the bearing conditions in rotating machinery, a system for journal bearing diagnosis by AE was developed. Acoustic emission technique is used to detect abnormal conditions in the bearing system. And various data such as AE events, rms voltage level of AE signals, and AE parameters were acquired during experiments with the simulated journal bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was accomplished. Bearing diagnosis system is composed of four parts as follows : sensing part for AE sensor and preamplifier, signal processing part for rms-to-dc converting to measure AE rms voltage, interface part for connecting rms signal to PC using A/D converter, graphic display and software part for display of bearing condition and for managing of diagnosis program.

  11. The sodium channel activator Lu AE98134 normalizes the altered firing properties of fast spiking interneurons in Dlx5/6+/- mice

    DEFF Research Database (Denmark)

    von Schoubye, Nadia Lybøl; Frederiksen, Kristen; Kristiansen, Uffe

    2018-01-01

    Mental disorders such as schizophrenia are associated with impaired firing properties of fast spiking inhibitory interneurons (FSINs) causing reduced task-evoked gamma-oscillation in prefrontal cortex. The voltage-gated sodium channel NaV1.1 is highly expressed in PV-positive interneurons, but only...... at low levels in principal cells. Positive modulators of Nav1.1 channels are for this reason considered potential candidates for the treatment of cognitive disorders. Here we examined the effect of the novel positive modulator of voltage-gated sodium channels Lu AE98134. We found that Lu AE98134...... facilitated the sodium current mediated by NaV1.1 expressed in HEK cells by shifting its activation to more negative values, decreasing its inactivation kinetics and promoting a persistent inward current. In a slice preparation from the brain of adult mice, Lu AE98134 promoted the excitability of fast spiking...

  12. ICP (ITER Collaborative Platform)

    Energy Technology Data Exchange (ETDEWEB)

    Capuano, C.; Carayon, F.; Patel, V. [ITER, 13 - St. Paul-Lez Durance (France)

    2009-07-01

    The ITER organization has the necessity to manage a massive amount of data and processes. Each team requires different process and databases often interconnected with those of others teams. ICP is the current central ITER repository of structured and unstructured data. All data in ICP is served and managed via a web interface that provides global accessibility with a common user friendly interface. This paper will explain the model used by ICP and how it serves the ITER project by providing a robust and agile platform. ICP is developed in ASP.NET using MSSQL Server for data storage. It currently houses 15 data driven applications, 150 different types of record, 500 k objects and 2.5 M references. During European working hours the system averages 150 concurrent users and 20 requests per second. ICP connects to external database applications to provide a single entry point to ITER data and a safe shared storage place to maintain this data long-term. The Core model provides an easy to extend framework to meet the future needs of the Organization. ICP follows a multi-tier architecture, providing logical separation of process. The standard three-tier architecture is expanded, with the data layer separated into data storage, data structure, and data access components. The business or applications logic layer is broken up into a common business functionality layer, a type specific logic layer, and a detached work-flow layer. Finally the presentation tier comprises a presentation adapter layer and an interface layer. Each layer is built up from small blocks which can be combined to create a wide range of more complex functionality. Each new object type developed gains access to a wealth of existing code functionality, while also free to adapt and extend this. The hardware structure is designed to provide complete redundancy, high availability and to handle high load. This document is composed of an abstract followed by the presentation transparencies. (authors)

  13. Detection method based on Kalman filter for high speed rail defect AE signal on wheel-rail rolling rig

    Science.gov (United States)

    Hao, Qiushi; Shen, Yi; Wang, Yan; Zhang, Xin

    2018-01-01

    Nondestructive test (NDT) of rails has been carried out intermittently in traditional approaches, which highly restricts the detection efficiency under rapid development of high speed railway nowadays. It is necessary to put forward a dynamic rail defect detection method for rail health monitoring. Acoustic emission (AE) as a practical real-time detection technology takes advantage of dynamic AE signal emitted from plastic deformation of material. Detection capacities of AE on rail defects have been verified due to its sensitivity and dynamic merits. Whereas the application under normal train service circumstance has been impeded by synchronous background noises, which are directly linked to the wheel speed. In this paper, surveys on a wheel-rail rolling rig are performed to investigate defect AE signals with varying speed. A dynamic denoising method based on Kalman filter is proposed and its detection effectiveness and flexibility are demonstrated by theory and computational results. Moreover, after comparative analysis of modelling precision at different speeds, it is predicted that the method is also applicable for high speed condition beyond experiments.

  14. Determination of hafnium at the 10−4% level (relative to zirconium content) using neutron activation analysis, inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Smolik, Marek; Polkowska-Motrenko, Halina; Hubicki, Zbigniew; Jakóbik-Kolon, Agata; Danko, Bożena

    2014-01-01

    Graphical abstract: -- Highlights: •We worked out ICP-MS method of Hf determination in Zr and Zr compounds. •We used NAA method as reference one. •We obtained pure zirconium matrix by ion exchange (Diphonix ® resin). •These permit to determine ≥1 × 10 −4 % Hf in Zr sample by ICP MS with good precision and accuracy. -- Abstract: Hafnium at the very low level of 1–8 ppm (in relation to zirconium) was determined in zirconium sulfate solutions (originating from investigations of the separation of ca. 44 ppm Hf from zirconium by means of the ion exchange method) by using three independent methods: inductively coupled plasma mass spectrometry (ICP MS), neutron activation analysis (NAA) and inductively coupled plasma atomic emission spectrometry (ICP-AES). The results of NAA and ICP MS determinations were consistent with each other across the entire investigated range (the RSD of both methods did not exceed 38%). The results of ICP-AES determination were more diverse, particularly at less than 5 ppm Hf (RSD was significantly higher: 29–253%). The ion exchange method exploiting Diphonix ® resin proved sufficient efficiency in Zr–Hf separation when the initial concentration ratio of the elements ([Zr] 0 /[Hf] 0 ) ranged from 1200 to ca. 143,000

  15. Chromosome isolation by flow sorting in Aegilops umbellulata and Ae. comosa and their allotetraploid hybrids Ae. biuncialis and Ae. geniculata.

    Directory of Open Access Journals (Sweden)

    István Molnár

    Full Text Available This study evaluates the potential of flow cytometry for chromosome sorting in two wild diploid wheats Aegilops umbellulata and Ae. comosa and their natural allotetraploid hybrids Ae. biuncialis and Ae. geniculata. Flow karyotypes obtained after the analysis of DAPI-stained chromosomes were characterized and content of chromosome peaks was determined. Peaks of chromosome 1U could be discriminated in flow karyotypes of Ae. umbellulata and Ae. biuncialis and the chromosome could be sorted with purities exceeding 95%. The remaining chromosomes formed composite peaks and could be sorted in groups of two to four. Twenty four wheat SSR markers were tested for their position on chromosomes of Ae. umbellulata and Ae. comosa using PCR on DNA amplified from flow-sorted chromosomes and genomic DNA of wheat-Ae. geniculata addition lines, respectively. Six SSR markers were located on particular Aegilops chromosomes using sorted chromosomes, thus confirming the usefulness of this approach for physical mapping. The SSR markers are suitable for marker assisted selection of wheat-Aegilops introgression lines. The results obtained in this work provide new opportunities for dissecting genomes of wild relatives of wheat with the aim to assist in alien gene transfer and discovery of novel genes for wheat improvement.

  16. A new method for the determination of plutonium and americium using high pressure microwave digestion and alpha-spectrometry or ICP-SMS

    International Nuclear Information System (INIS)

    Luisier, F.; Corcho Alvarado, J.A.; Froidevaux, P.; Steinmann, P.; Krachler, M.

    2009-01-01

    Plutonium and americium are radionuclides particularly difficult to measure in environmental samples because they are a-emitters and therefore necessitate a careful separation before any measurement, either using radiometric methods or ICP-SMS. Recent developments in extraction chromatography resins such as Eichrom R TRU and TEVA have resolved many of the analytical problems but drawbacks such as low recovery and spectral interferences still occasionally occur. Here, we report on the use of the new Eichrom R DGA resin in association with TEVA resin and high pressure microwave acid leaching for the sequential determination of plutonium and americium in environmental samples. The method results in average recoveries of 83 ± 15% for plutonium and 73 ± 22% for americium (n = 60), and a less than 10% deviation from reference values of four IAEA reference materials and three samples from intercomparisons exercises. The method is also suitable for measuring 239 Pu in water samples at the μBq/l level, if ICP-SMS is used for the measurement. (author)

  17. Results on the role of metastable Ar atoms in a 9-MHz high-power atmospheric ICP by using emission/absorption spectrometry

    International Nuclear Information System (INIS)

    Gunter, W.; Zeeman, P.B.; Visser, K.

    1984-01-01

    An investigation into the role of overpopulations of metastable argon levels as agents for causing non-local thermal equilibrium (LTE) in an inductively coupled plasma source (ICP), was carried out. Four argon transitions in the near infrared region were monitored through absorption measurements at two different observation heights in a 9-MHz high-power ICP. The lower states of the four transitions consist of two metastable (11.55 and 11.72 eV) and two radiating (11.62 and 11.83 eV) levels. Comparison of measured metastable level to radiating level absorbance ratios with calculated population ratios gave an indication whether overpopulations of certain levels existed. Results indicate no overpopulation of metastable states with respect to radiating states, arguing against their role as non-LTE mechanism agents. This conclusion is, however, preliminary, since the calculation of absolute population densities from absorbance measurements must still be carried out

  18. A novel procedure for Rubidium separation and its isotope measurements on geological samples by MC-ICP-MS

    Science.gov (United States)

    Ma, J.; Zhang, Z.; Wei, G.; Zhang, L.

    2017-12-01

    A method including a novel column Rb separation procedure and high-precision Rb isotope measurement in geological materials by using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) in standard-sample-bracketing (SSB) mode has been developed. Sr-Spec resin was employed, in which the distribution coefficients for Rb, K, Ba and Sr are different in nitric acid, to sequentially separate them from the matrix. The dissolved samples were loaded on the column in 3 M HNO3, the main matrix such as Al, Ca, Fe, Mg, Mn and Na were removed by rinsing with 4.5 mL HNO3, Rb and K were then sequentially eluted by 3 M HNO3 in different volumes. After that, Ba was eluted by 8 M HNO3, and Sr was finally eluted by Milli-Q water. This enable us to collect the pure Rb, K, Ba and Sr one by one with recovery close to 100% for their isotopic compositions measurement on MC-ICP-MS. We here focus on Rb isotope measurement. The measurement using MC-ICP-MS yielded an internal precision for δ87Rb of external precision was generally better than ± 0.06‰ (2SD) based on the long-term results of the Rb standard solutions NIST SRM 984. A series of geological rock standards, were analyzed using this method, and the results indicate significant Rb isotope differences in different geologic materials. This will provide a powerful tool to investigate Rb isotope fractionation during geological processes.Based on this method, Rb isotope compositions from a basaltic weathering profile were carried out. The data show the lighter Rb (85Rb) isotope is preferentially leached from the weathering profile and remains heavy Rb isotope (87Rb) in the weathered residues during the incipient weathering stage. From the moderate to advanced weathering stage, the significant variations of Rb isotope were observed and multiple factors, such as leaching, adsorption, desorption, and precipitation, should play important role in fractionating Rb isotope.

  19. Determination of uranium in natural waters and high-purity aluminum by flow-injection on-line preconcentration and ICP-MS detection

    International Nuclear Information System (INIS)

    Seki, Tatsuya; Oguma, Koichi

    2004-01-01

    A flow injection method has been developed for the determination of uranium is natural waters and high-purity aluminum by use of on-line preconcentration on a U/TEVA TM column and ICP-MS detection. The sample solution prepared as a nitric acid solution in 3 mol l -1 was passed through the U/TEVA TM column to collect uranium and uranium adsorbed was eluted with 0.1 mol l -1 nitric acid. The effluent was introduced directly into the nebulizer of the ICP-MS and 238 U was measured. The detection limit, calculated as 3-times the standard deviation of the background noise, was 3pg and the sample throughput was about 10 per hour. The proposed method was successfully applied to the determination of uranium in river-water reference materials, a seawater reference material and high-purity aluminum reference materials. (author)

  20. Characterization of Aes nuclear foci in colorectal cancer cells

    Science.gov (United States)

    Itatani, Yoshiro; Sonoshita, Masahiro; Kakizaki, Fumihiko; Okawa, Katsuya; Stifani, Stefano; Itoh, Hideaki; Sakai, Yoshiharu; Taketo, M. Mark

    2016-01-01

    Amino-terminal enhancer of split (Aes) is a member of Groucho/Transducin-like enhancer (TLE) family. Aes is a recently found metastasis suppressor of colorectal cancer (CRC) that inhibits Notch signalling, and forms nuclear foci together with TLE1. Although some Notch-associated proteins are known to form subnuclear bodies, little is known regarding the dynamics or functions of these structures. Here, we show that Aes nuclear foci in CRC observed under an electron microscope are in a rather amorphous structure, lacking surrounding membrane. Investigation of their behaviour during the cell cycle by time-lapse cinematography showed that Aes nuclear foci dissolve during mitosis and reassemble after completion of cytokinesis. We have also found that heat shock cognate 70 (HSC70) is an essential component of Aes foci. Pharmacological inhibition of the HSC70 ATPase activity with VER155008 reduces Aes focus formation. These results provide insight into the understanding of Aes-mediated inhibition of Notch signalling. PMID:26229111

  1. The determination of cadmium, lead and vanadium by high resolution ICP-MS in Antarctic snow samples

    Energy Technology Data Exchange (ETDEWEB)

    Lanza, F. [Joh. Gutenberg Univ., Mainz (Germany). Inst. fuer Anorganische und Analytische Chemie; Trincherini, P. [European Union Joint Research Centre, Ispra, VA (Italy). Inst. of Environment

    2000-02-01

    Double focusing ICP-MS was successfully used in this research for the direct determination of the cadmium, lead and vanadium content of a set of Antarctic samples collected during the 11. Italian Expedition to Antarctica. For cadmium and lead measurements the low resolution mode was chosen since it ensured the highest ion sensitivity and it allowed the highest detection limits to be attained; in the case of vanadium the high resolution mode was used to solve the isobaric interference. As far as vanadium and cadmium are concerned by GFAAS coupled with different preconcentration procedures. The vanadium, cadmium and lead content measured in a riverine water reference material (SRLS-3) was found in agreement with the certified values. [Italian] Si e' utilizzato uno spettrometro ICP-MS a doppia focalizzazione per la determinazione diretta di cadmio, piombo e vanadio in una serie di campioni di neve antartica superficiale raccolta durante l'undicesima spedizione italiana in Antartide. Per le determinazioni di cadmio e piombo si e' scelta la procedura a bassa risoluzione, che ha garantito la piu' elevata sensibilita' ed ha permesso di ottenere limiti di determinazione migliori; nel caso del vanadio si e' utilizzata la procedura ad alta risoluzione che ha permesso di risolvere problemi di interferenza isobarica. Per quanto riguarda cadmio e vanadio, i risultati delle determinazioni mediante ICP-MS sono risultati in buon accordo con quelli ottenuti mediante GFAAS accoppiata a diverse procedure di preconcentrazione. Il contenuto di cadmio, piombo e vanadio misurato con le procedure sviluppate in un campione certificato di acqua di fiume (SRLS-3) e' risultato in accordo con i valori certificati.

  2. Ru Nanoparticles Supported on MIL-101 by Double Solvents Method as High-Performance Catalysts for Catalytic Hydrolysis of Ammonia Borane

    Directory of Open Access Journals (Sweden)

    Tong Liu

    2015-01-01

    Full Text Available Highly dispersed crystalline Ru nanoparticles (NPs were successfully immobilized inside the pores of MIL-101 by a double solvents method (DSM. HRTEM clearly demonstrated the uniform distribution of the ultrafine Ru NPs throughout the interior cavities of MIL-101. The synthesized Ru@MIL-101 catalyst was also characterized by X-ray diffraction (XRD, N2 adsorption desorption, and ICP-AES. The catalytic test indicated that the Ru NPs supported MIL-101 material exhibited exceedingly high activity and excellent durability for hydrogen generation from the catalytic hydrolysis of amine boranes.

  3. Determination of the total drug-related chlorine and bromine contents in human blood plasma using high performance liquid chromatography-tandem ICP-mass spectrometry (HPLC-ICP-MS/MS).

    Science.gov (United States)

    Klencsár, Balázs; Bolea-Fernandez, Eduardo; Flórez, María R; Balcaen, Lieve; Cuyckens, Filip; Lynen, Frederic; Vanhaecke, Frank

    2016-05-30

    A fast, accurate and precise method for the separation and determination of the total contents of drug-related Cl and Br in human blood plasma, based on high performance liquid chromatography - inductively coupled plasma - tandem mass spectrometry (HPLC-ICP-MS/MS), has been developed. The novel approach was proved to be a suitable alternative to the presently used standard methodology (i.e. based on a radiolabelled version of the drug molecule and radiodetection), while eliminating the disadvantages of the latter. Interference-free determination of (35)Cl has been accomplished via ICP-MS/MS using H2 as reaction gas and monitoring the (35)ClH2(+) reaction product at mass-to-charge ratio of 37. Br could be measured "on mass" at a mass-to-charge of 79. HPLC was relied on for the separation of the drug-related entities from the substantial amount of inorganic Cl. The method developed was found to be sufficiently precise (repeatability 0.990) from the limit of quantification (0.05 and 0.01 mg/L for Cl and Br in blood plasma, respectively) to at least 5 and 1mg/L for Cl and Br, respectively. Quantification via either external or internal standard calibration provides reliable results for both elements. As a proof-of-concept, human blood plasma samples from a clinical study involving a newly developed Cl- and Br-containing active pharmaceutical ingredient were analysed and the total drug exposure was successfully described. Cross-validation was achieved by comparing the results obtained on Cl- and on Br-basis. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Determination of (90)Sr in soil samples using inductively coupled plasma mass spectrometry equipped with dynamic reaction cell (ICP-DRC-MS).

    Science.gov (United States)

    Feuerstein, J; Boulyga, S F; Galler, P; Stingeder, G; Prohaska, T

    2008-11-01

    A rapid method is reported for the determination of (90)Sr in contaminated soil samples in the vicinity of the Chernobyl Nuclear Power Plant by ICP-DRC-MS. Sample preparation and measurement procedures focus on overcoming the isobaric interference of (90)Zr, which is present in soils at concentrations higher by more than six orders of magnitude than (90)Sr. Zirconium was separated from strontium in two steps to reduce the interference by (90)Zr(+) ions by a factor of more than 10(7): (i) by ion exchange using a Sr-specific resin and (ii) by reaction with oxygen as reaction gas in a dynamic reaction cell (DRC) of a quadrupole ICP-MS. The relative abundance sensitivity of the ICP-MS was studied systematically and the peak tailing originating from (88)Sr on mass 90 u was found to be about 3 x 10(-9). Detection limits of 4 fg g(-1) (0.02 Bq g(-1)) were achieved when measuring Sr solutions containing no Zr. In digested uncontaminated soil samples after matrix separation as well as in a solution of 5 microg g(-1) Sr and 50 ng g(-1) Zr a detection limit of 0.2 pg g(-1) soil (1 Bq g(-1) soil) was determined. (90)Sr concentrations in three soil samples collected in the vicinity of the Chernobyl Nuclear Power Plant were 4.66+/-0.27, 13.48+/-0.68 and 12.9+/-1.5 pg g(-1) corresponding to specific activities of 23.7+/-1.3, 68.6+/-3.5 and 65.6+/-7.8 Bq g(-1), respectively. The ICP-DRC-MS results were compared to the activities measured earlier by radiometry. Although the ICP-DRC-MS is inferior to commonly used radiometric methods with respect to the achievable minimum detectable activity it represents a time- and cost-effective alternative technique for fast monitoring of high-level (90)Sr contamination in environmental or nuclear industrial samples down to activities of about 1 Bq g(-1).

  5. Determination of 90Sr in soil samples using inductively coupled plasma mass spectrometry equipped with dynamic reaction cell (ICP-DRC-MS)

    International Nuclear Information System (INIS)

    Feuerstein, J.; Boulyga, S.F.; Galler, P.; Stingeder, G.; Prohaska, T.

    2008-01-01

    A rapid method is reported for the determination of 90 Sr in contaminated soil samples in the vicinity of the Chernobyl Nuclear Power Plant by ICP-DRC-MS. Sample preparation and measurement procedures focus on overcoming the isobaric interference of 90 Zr, which is present in soils at concentrations higher by more than six orders of magnitude than 90 Sr. Zirconium was separated from strontium in two steps to reduce the interference by 90 Zr + ions by a factor of more than 10 7 : (i) by ion exchange using a Sr-specific resin and (ii) by reaction with oxygen as reaction gas in a dynamic reaction cell (DRC) of a quadrupole ICP-MS. The relative abundance sensitivity of the ICP-MS was studied systematically and the peak tailing originating from 88 Sr on mass 90 u was found to be about 3 x 10 -9 . Detection limits of 4 fg g -1 (0.02 Bq g -1 ) were achieved when measuring Sr solutions containing no Zr. In digested uncontaminated soil samples after matrix separation as well as in a solution of 5 μg g -1 Sr and 50 ng g -1 Zr a detection limit of 0.2 pg g -1 soil (1 Bq g -1 soil) was determined. 90 Sr concentrations in three soil samples collected in the vicinity of the Chernobyl Nuclear Power Plant were 4.66 ± 0.27, 13.48 ± 0.68 and 12.9 ± 1.5 pg g -1 corresponding to specific activities of 23.7 ± 1.3, 68.6 ± 3.5 and 65.6 ± 7.8 Bq g -1 , respectively. The ICP-DRC-MS results were compared to the activities measured earlier by radiometry. Although the ICP-DRC-MS is inferior to commonly used radiometric methods with respect to the achievable minimum detectable activity it represents a time- and cost-effective alternative technique for fast monitoring of high-level 90 Sr contamination in environmental or nuclear industrial samples down to activities of about 1 Bq g -1

  6. AE Recorder Characteristics and Development.

    Energy Technology Data Exchange (ETDEWEB)

    Partridge, Michael E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Curtis, Shane Keawe [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); McGrogan, David Paul [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    The Anomalous Environment Recorder (AE Recorder) provides a robust data recording capability for multiple high-shock applications including earth penetrators. The AE Recorder, packaged as a 2.4" di ameter cylinder 3" tall, acquires 12 accelerometer, 2 auxiliary, and 6 discrete signal channels at 250k samples / second. Recording depth is 213 seconds plus 75ms of pre-trigger data. The mechanical, electrical, and firmware are described as well as support electro nics designed for the first use of the recorder.

  7. Optimization of DIII-D discharges to avoid AE destabilization

    Science.gov (United States)

    Varela, Jacobo; Spong, Donald; Garcia, Luis; Huang, Juan; Murakami, Masanori

    2017-10-01

    The aim of the study is to analyze the stability of Alfven Eigenmodes (AE) perturbed by energetic particles (EP) during DIII-D operation. We identify the optimal NBI operational regimes that avoid or minimize the negative effects of AE on the device performance. We use the reduced MHD equations to describe the linear evolution of the poloidal flux and the toroidal component of the vorticity in a full 3D system, coupled with equations of density and parallel velocity moments for the energetic particles, including the effect of the acoustic modes. We add the Landau damping and resonant destabilization effects using a closure relation. We perform parametric studies of the MHD and AE stability, taking into account the experimental profiles of the thermal plasma and EP, also using a range of values of the energetic particles β, density and velocity as well the effect of the toroidal couplings. We reproduce the AE activity observed in high poloidal β discharge at the pedestal and reverse shear discharges. This material based on work is supported both by the U.S. Department of Energy, Office of Science, under Contract DE-AC05-00OR22725 with UT-Battelle, LLC. Research sponsored in part by the Ministerio de Economia y Competitividad of Spain under the project.

  8. Crack classification in concrete beams using AE parameters

    Science.gov (United States)

    Bahari, N. A. A. S.; Shahidan, S.; Abdullah, S. R.; Ali, N.; Zuki, S. S. Mohd; Ibrahim, M. H. W.; Rahim, M. A.

    2017-11-01

    The acoustic emission (AE) technique is an effective tool for the evaluation of crack growth. The aim of this study is to evaluate crack classification in reinforced concrete beams using statistical analysis. AE has been applied for the early monitoring of reinforced concrete structures using AE parameters such as average frequency, rise time, amplitude counts and duration. This experimental study focuses on the utilisation of this method in evaluating reinforced concrete beams. Beam specimens measuring 150 mm × 250 mm × 1200 mm were tested using a three-point load flexural test using Universal Testing Machines (UTM) together with an AE monitoring system. The results indicated that RA value can be used to determine the relationship between tensile crack and shear movement in reinforced concrete beams.

  9. Energy efficiency analysis and implementation of AES on an FPGA

    Science.gov (United States)

    Kenney, David

    The Advanced Encryption Standard (AES) was developed by Joan Daemen and Vincent Rjimen and endorsed by the National Institute of Standards and Technology in 2001. It was designed to replace the aging Data Encryption Standard (DES) and be useful for a wide range of applications with varying throughput, area, power dissipation and energy consumption requirements. Field Programmable Gate Arrays (FPGAs) are flexible and reconfigurable integrated circuits that are useful for many different applications including the implementation of AES. Though they are highly flexible, FPGAs are often less efficient than Application Specific Integrated Circuits (ASICs); they tend to operate slower, take up more space and dissipate more power. There have been many FPGA AES implementations that focus on obtaining high throughput or low area usage, but very little research done in the area of low power or energy efficient FPGA based AES; in fact, it is rare for estimates on power dissipation to be made at all. This thesis presents a methodology to evaluate the energy efficiency of FPGA based AES designs and proposes a novel FPGA AES implementation which is highly flexible and energy efficient. The proposed methodology is implemented as part of a novel scripting tool, the AES Energy Analyzer, which is able to fully characterize the power dissipation and energy efficiency of FPGA based AES designs. Additionally, this thesis introduces a new FPGA power reduction technique called Opportunistic Combinational Operand Gating (OCOG) which is used in the proposed energy efficient implementation. The AES Energy Analyzer was able to estimate the power dissipation and energy efficiency of the proposed AES design during its most commonly performed operations. It was found that the proposed implementation consumes less energy per operation than any previous FPGA based AES implementations that included power estimations. Finally, the use of Opportunistic Combinational Operand Gating on an AES cipher

  10. LLNL large-area inductively coupled plasma (ICP) source: Experiments

    International Nuclear Information System (INIS)

    Richardson, R.A.; Egan, P.O.; Benjamin, R.D.

    1995-05-01

    We describe initial experiments with a large (76-cm diameter) plasma source chamber to explore the problems associated with large-area inductively coupled plasma (ICP) sources to produce high density plasmas useful for processing 400-mm semiconductor wafers. Our experiments typically use a 640-nun diameter planar ICP coil driven at 13.56 MHz. Plasma and system data are taken in Ar and N 2 over the pressure range 3-50 mtorr. RF inductive power was run up to 2000W, but typically data were taken over the range 100-1000W. Diagnostics include optical emission spectroscopy, Langmuir probes, and B probes as well as electrical circuit measurements. The B and E-M measurements are compared with models based on commercial E-M codes. Initial indications are that uniform plasmas suitable for 400-mm processing are attainable

  11. Fast Oblivious AES A Dedicated application of the MiniMac protocol

    DEFF Research Database (Denmark)

    Zakarias, Rasmus Winther; Damgård, Ivan Bjerre

    2015-01-01

    We present an actively secure multi-partycomputation of the Advanced Encryption Standard (AES). To the best of our knowledge it is the fastest of its kind to date. We start from an efficient actively secure evaluation of general binary circuits that was implemented by the authors of [DLT14......]. They presented an optimized implementation of the so-called MiniMac protocol [DZ13] that runs in the pre-processing model, and applied this to a binary AES circuit. In this paper we de- scribe how to dedicate the pre-processing to the structure of AES, which improves significantly the throughput and latency...... of previous actively secure implementations. We get a latency of about 6 ms and amortised time about 0.4 ms per AES block, which seems completely adequate for practical applications such as verification of 1-time passwords....

  12. Measurement of elemental speciation by liquid chromatography -- inductively coupled plasma mass spectrometry (LC-ICP-MS) with the direct injection nebulizer (DIN)

    Energy Technology Data Exchange (ETDEWEB)

    Shum, Sam [Iowa State Univ., Ames, IA (United States)

    1993-05-01

    This thesis is divided into 4 parts: elemental speciation, speciation of mercury and lead compounds by microbore column LC-ICP-MS with direct injection nebulization, spatially resolved measurements of size and velocity distributions of aerosol droplets from a direct injection nebulizer, and elemental speciation by anion exchange and size exclusion chromatography with detection by ICP-MS with direct injection nebulization.

  13. Simultaneous quantification of iodine and high valent metals via ICP-MS under acidic conditions in complex matrices.

    Science.gov (United States)

    Brix, Kristina; Hein, Christina; Sander, Jonas Michael; Kautenburger, Ralf

    2017-05-15

    The determination of iodine as a main fission product (especially the isotopes I-129 and I-131) of stored HLW in a disposal beside its distribution as a natural ingredient of many different products like milk, food and seawater is a matter of particular interest. The simultaneous ICP-MS determination of iodine as iodide together with other elements (especially higher valent metal ions) relevant for HLW is analytically very problematic. A reliable ICP-MS quantification of iodide must be performed at neutral or alkaline conditions in contrast to the analysis of metal ions which are determined in acidic pH ranges. Herein, we present a method to solve this problem by changing the iodine speciation resulting in an ICP-MS determination of iodide as iodate. The oxidation from iodide to iodate with sodium hypochlorite at room temperature is a fast and convenient method with flexible reaction time, from one hour up to three days, thus eliminating the disadvantages of quantifying iodine species via ICP-MS. In the analysed concentration range of iodine (0.1-100µgL -1 ) we obtain likely quantitative recovery rates for iodine between 91% and 102% as well as relatively low RSD values (0.3-4.0%). As an additional result, it is possible to measure different other element species in parallel together with the generated iodate, even high valent metals (europium and uranium beside caesium) at recovery rates in the same order of magnitude (93-104%). In addition, the oxidation process operates above pH 7 thus offering a wide pH range for sample preparation. Even analytes in complex matrices, like 5M saline (NaCl) solution or artificial cement pore water (ACW) can be quantified with this robust sample preparation method. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g(-1) levels.

    Science.gov (United States)

    Boulyga, Sergei F; Tibi, Markus; Heumann, Klaus G

    2004-01-01

    The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3x10(-13) g g(-1) for Pu isotopes in soil samples containing uranium at a concentration of a few microg g(-1). The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH+ and PbO2+ ions and by the peak tail of 238U+ ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of alpha-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of (239+240)Pu (9.8 +/- 3.0 mBq g(-1)) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4 +/- 0.2 mBq g(-1). However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if "hot" particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples.

  15. Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g-1 levels

    International Nuclear Information System (INIS)

    Boulyga, Sergei F.; Tibi, Markus; Heumann, Klaus G.

    2004-01-01

    The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3 x 10 -13 g g -1 for Pu isotopes in soil samples containing uranium at a concentration of a few μg g -1 . The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH + and PbO 2 + ions and by the peak tail of 238 U + ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of α-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of 239+240 Pu (9.8±3.0 mBq g -1 ) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4±0.2 mBq g -1 . However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if ''hot'' particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples. (orig.)

  16. High-precision isotopic characterization of USGS reference materials by TIMS and MC-ICP-MS

    Science.gov (United States)

    Weis, Dominique; Kieffer, Bruno; Maerschalk, Claude; Barling, Jane; de Jong, Jeroen; Williams, Gwen A.; Hanano, Diane; Pretorius, Wilma; Mattielli, Nadine; Scoates, James S.; Goolaerts, Arnaud; Friedman, Richard M.; Mahoney, J. Brian

    2006-08-01

    The Pacific Centre for Isotopic and Geochemical Research (PCIGR) at the University of British Columbia has undertaken a systematic analysis of the isotopic (Sr, Nd, and Pb) compositions and concentrations of a broad compositional range of U.S. Geological Survey (USGS) reference materials, including basalt (BCR-1, 2; BHVO-1, 2), andesite (AGV-1, 2), rhyolite (RGM-1, 2), syenite (STM-1, 2), granodiorite (GSP-2), and granite (G-2, 3). USGS rock reference materials are geochemically well characterized, but there is neither a systematic methodology nor a database for radiogenic isotopic compositions, even for the widely used BCR-1. This investigation represents the first comprehensive, systematic analysis of the isotopic composition and concentration of USGS reference materials and provides an important database for the isotopic community. In addition, the range of equipment at the PCIGR, including a Nu Instruments Plasma MC-ICP-MS, a Thermo Finnigan Triton TIMS, and a Thermo Finnigan Element2 HR-ICP-MS, permits an assessment and comparison of the precision and accuracy of isotopic analyses determined by both the TIMS and MC-ICP-MS methods (e.g., Nd isotopic compositions). For each of the reference materials, 5 to 10 complete replicate analyses provide coherent isotopic results, all with external precision below 30 ppm (2 SD) for Sr and Nd isotopic compositions (27 and 24 ppm for TIMS and MC-ICP-MS, respectively). Our results also show that the first- and second-generation USGS reference materials have homogeneous Sr and Nd isotopic compositions. Nd isotopic compositions by MC-ICP-MS and TIMS agree to within 15 ppm for all reference materials. Interlaboratory MC-ICP-MS comparisons show excellent agreement for Pb isotopic compositions; however, the reproducibility is not as good as for Sr and Nd. A careful, sequential leaching experiment of three first- and second-generation reference materials (BCR, BHVO, AGV) indicates that the heterogeneity in Pb isotopic compositions

  17. 高分解能ICP-MSの特徴とその測定例<総説 レビュー>

    OpenAIRE

    石井, 清孝

    2000-01-01

    At present, there are two kind of the instruments of ICP-MS. One is HR-ICP-MS that used double focusing mass spectrometer the other one is Q-ICP-MS that used a quadrupole mass spectrometer. HR-ICP-MS has many characteristics in comparison with Q-ICP-MS. It is reported of the HR-ICP-MS structure and characteristics and also reported one of the examples of the measurement that made the most of the characteristic of it’s high resolving power in this time.概要:現在,一般的に使用されているICP-MS にはその分光器に四重極形質量分析計...

  18. Basic chemistry for radioactive waste management

    International Nuclear Information System (INIS)

    Eom, Tae Yoon; Suh, Moo Yul; Joe, Kih Soo; Chung, Yong Sam; Kim, Jung Suk; Sohn, Se Chul; Han, Sun Ho; Jee, Kwang Yong; Choi, Kwang Soon; Lee, Chang Heon

    1991-03-01

    Chemical analysis methods on geological materials were investigated for the evaluation of radioactive waste disposal site, and the scope and contents weer as follows: -Determination of the major and trace elements in granite rocks by ICP-AES and INAA: Experimental conditions of ICP-AES and INAA were established with geological standard rock, USGS-G2. The ICP-AES was found to be better both in precision and in accuracy than the INAA for major elements. The precision and the accuracy of the ICP-AES method were about 6% and +/- 10%, respectively. -Determination of inorganic and organic anions by ion chromatography and prediction of retention times : Analytical methods for inorganic anions was established with NaOH eluents by ion chromatography. Studies on the prediction of retention times of the anions for gradient elution was carried out using the stepwise elution equation. The slope from the plot of log K' against log [OH - ] was obtained by a linear regression, and a good agreement was obtained between the experimental and the calculated values. -Development of analytical methods for the determination of Co, Ni and In by differential-pulse adsorptive stripping voltametry and ferrous and ferric ions by spectrometry : Detection limits of Co, Ni and In were 0.02, 0.05 and 0.2 ppb, respectively, and the content of ferrous and ferric ion in KAERI ground water were 0.12 and 0.08 ppm respectively. -Determination of trace uranium in groundwaters by neutron activation analysis : Uranium in KAERI groundwater was preconcentrated on the chelating resin, Chelex-100 and the uranium content was measured by neutron activation analysis. The analytical result was 4.5 ppb with standard deviation of 0.049. (Author)

  19. ICP-MS analysis for long-lived radionuclides

    International Nuclear Information System (INIS)

    Roos, P.

    2010-01-01

    Full text: Inductively coupled plasma mass spectrometry (ICP-MS) is an attractive alternative for the analysis of radioisotopes having a half-life in the order of several hundred years and above. The technique should not be considered a replacement for radiometric measurements of these isotopes but merely an alternative. Similarly to radiometric techniques like alpha and beta spectrometry most analysis of 'low-level' concentrations by ICP-MS requires chemical isolation of the element in question. For 'ultra-low-level' concentrations this clean-up of the sample is usually even more necessary than for the alternative radiometric techniques. The presentation gives an overview of advantages and disadvantages in using ICP-MS and compares it to relevant radiometric alternatives. (author)

  20. Determination of actinides using ICP-SFMS

    International Nuclear Information System (INIS)

    Nygren, Ulrika

    2006-01-01

    Interest in the determination of the actinides using ICP-MS has steadily increased with the development of systems capable of more sensitive and precise measurements. However, the analysis of less abundant actinides such as Pu and Am is not straightforward due to the need for chemical separation of these elements prior to determination. In many applications of mass-spectrometric actinide analysis, isotope ratio measurements are important, either for the analysis of the isotopic composition of, e.g., U or Pu in the sample, or for quantitative determinations using isotope dilution mass spectrometry. In order to achieve high precision and accuracy in an isotope ratio measurement, corrections for instrumentally induced systematic errors, e.g., due to dead-time and mass bias, need to be considered. In this thesis, different aspects of actinide analysis using ICP-SFMS have been addressed. In Papers I and III, separation procedures based on solid phase extraction for Pu, Am and U were developed and evaluated with respect to chemical yield and separation from elements causing spectral interferences. Applications of the analytical procedures developed comprised measurement of the 240 Pu/ 2 3 9Pu ratio in environmental reference materials, and age determination of Pu based on the 241 Pu/ 241 Am and 240 Pu/ 236 U ratios. In the application of different separation procedures for Pu, previously unidentified spectral interferences were discovered. In Paper II, these interferences were identified as lanthanide phosphate ions and the composition and formation of these species with respect to different instrumental parameters were further examined. Due to the importance of precise and accurate isotope ratio determination, a thorough investigation of the instrumental dead time of an ICP-SFMS system was performed. The dead time was evaluated via both isotope ratio and electronic measurements of the output from the detector amplifier. It was found that the overall uncertainty in ratio

  1. Round robin 'Impurities in uranium matrix': a success for CETAMA and IAEA

    International Nuclear Information System (INIS)

    Granier, Guy; Roudil, Daniele; Balsley, Steven Devry; Bulyha, Siarhei; Aregbe, Yetunde

    2012-01-01

    The safeguard of nuclear material is of paramount importance to the IAEA which increasingly uses this information for characterization purposes in order to strengthen the verification of declared nuclear material and to identify the origin of samples from mines. IAEA tasked CETAMA to conduct a round robin with objective to evaluate the capability of laboratories to measure impurities in uranium with concentration levels between 1 and 500 ppm relative to uranium. This round robin was attended by 17 international laboratories from the nuclear industry and safeguards community. The results are mainly obtained by ICP-MS and ICP-AES. The synthesis of this round robin were helpful in identifying anomalies and will allow the IAEA to better set realistic measurement performance targets for ICP-MS and ICP-AES. (authors)

  2. Study, analysis, assess and compare the nuclear engineering systems of nuclear power plant with different reactor types VVER-1000, namely AES-91, AES-92 and AES-2006

    International Nuclear Information System (INIS)

    Le Van Hong; Tran Chi Thanh; Hoang Minh Giang; Le Dai Dien; Nguyen Nhi Dien; Nguyen Minh Tuan

    2015-01-01

    On November 25, 2009, in Hanoi, the National Assembly had been approved the resolution about policy for investment of nuclear power project in Ninh Thuan province which include two sites, each site has two units with power around 1000 MWe. For the nuclear power project at Ninh Thuan 1, Vietnam Government signed the Joint-Governmental Agreement with Russian Government for building the nuclear power plant with reactor type VVER. At present time, the Russian Consultant proposed four reactor technologies can be used for Ninh Thuan 1 project, namely: AES-91, AES-92, AES-2006/V491 and AES-2006/V392M. This report presents the main reactor engineering systems of nuclear power plants with VVER-1000/1200. The results from analysis, comparison and assessment between the designs of AES-91, AES-92 and AES-2006 are also presented. The obtained results show that the type AES-2006 is appropriate selection for Vietnam. (author)

  3. Determination of phosphorus in small amounts of protein samples by ICP-MS.

    Science.gov (United States)

    Becker, J Sabine; Boulyga, Sergei F; Pickhardt, Carola; Becker, J; Buddrus, Stefan; Przybylski, Michael

    2003-02-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is used for phosphorus determination in protein samples. A small amount of solid protein sample (down to 1 micro g) or digest (1-10 micro L) protein solution was denatured in nitric acid and hydrogen peroxide by closed-microvessel microwave digestion. Phosphorus determination was performed with an optimized analytical method using a double-focusing sector field inductively coupled plasma mass spectrometer (ICP-SFMS) and quadrupole-based ICP-MS (ICP-QMS). For quality control of phosphorus determination a certified reference material (CRM), single cell proteins (BCR 273) with a high phosphorus content of 26.8+/-0.4 mg g(-1), was analyzed. For studies on phosphorus determination in proteins while reducing the sample amount as low as possible the homogeneity of CRM BCR 273 was investigated. Relative standard deviation and measurement accuracy in ICP-QMS was within 2%, 3.5%, 11% and 12% when using CRM BCR 273 sample weights of 40 mg, 5 mg, 1 mg and 0.3 mg, respectively. The lowest possible sample weight for an accurate phosphorus analysis in protein samples by ICP-MS is discussed. The analytical method developed was applied for the analysis of homogeneous protein samples in very low amounts [1-100 micro g of solid protein sample, e.g. beta-casein or down to 1 micro L of protein or digest in solution (e.g., tau protein)]. A further reduction of the diluted protein solution volume was achieved by the application of flow injection in ICP-SFMS, which is discussed with reference to real protein digests after protein separation using 2D gel electrophoresis.The detection limits for phosphorus in biological samples were determined by ICP-SFMS down to the ng g(-1) level. The present work discusses the figure of merit for the determination of phosphorus in a small amount of protein sample with ICP-SFMS in comparison to ICP-QMS.

  4. Comparison of inductively coupled plasma mass spectrometry with inductively coupled plasma atomic emission spectrometry and instrumental neutron activation analysis for the determination of rare earth elements in Greek bauxites

    International Nuclear Information System (INIS)

    Ochsenkuehn-Petropoulou, Maria; Luck, Joachim

    1991-01-01

    Fore the determination of rare earth elements (REE) in bauxitic materials the techniques of inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma atomic emission spectrometry (ICP-AES) and instrumental neutron activation analysis (INAA) were compared. In the NIST (National Institute of Standards and Technology) bauxites SRM 697 Dominican, and SRM 69 b Arkansas, the concentration of some REEs were determined. With the reference bauxite BX-N of the ARNT (Association Nationale de la Recherche Technique) the precision and accuracy of ICP-AES for the determination of REEs in bauxites was tested. Furthermore, Greek bauxites of the Parnassos-Giona area were investigated. In a comparison of the three methods it was possible to calculate from the data series the precision of each method, which showed that the tendency found in the deviations for the different REEs is in accordance with published values. Also the limits of detection for REEs in bauxites were calculated and found to be in the same range as those in the literature. (author)

  5. Evaluation of Fatty Acid Composition, Antioxidant and Antimicrobial Activity, Mineral Composition and Calorie Values of Some Nuts and Seeds from Turkey

    Directory of Open Access Journals (Sweden)

    Fatma Gülay Kırbaşlar

    2012-07-01

    Full Text Available The samples of the hazelnut, peanut, pistachio, almond, walnut, chestnut, pumpkin seed and sunflower seed were collected from Turkey. The fatty acid compositions of Turkish nut and seed oils were analyzed by Gas Chromatography (GC were determined. The antioxidant activity of the samples was assessed by 1,1-diphenyl-2-picrylhydrazyl (DPPH radical scavenging capacity assay toward BHT and Vitamin C. Retinol and a -tocopherol were analyzed using High-Pressure Liquid Chromatography with UV Detector (HPLC-UV. The antimicrobial and antifungal activities of Turkish nut and seeds were evaluated using the disk diffusion method toward 9 bacteria and 5 yeasts. The nut and seeds showed strong antimicrobial activity against the test organisms. Spectroscopic determination of minerals (Calcium, magnesium, potassium, sodium, iron, copper, manganese, selenium, zinc, chromium, aluminum of nuts and seeds was performed with inductively coupled plasma-atomic emission spectrometer (ICP-AES. The calorie values of samples were measured using a Bomb Calorimeter.

  6. Inductively coupled plasma mass spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Shimamura, Tadashi

    1997-01-01

    The period of investigation for the previous general remarks on the progress of ICP-MS was from January, 1991 to September, 1993. In the investigation of this time, for the object of the Chemical Abstracts from January, 1994 to September, 1996, retrieval was carried out by using the STN International. As the key words, ICP-MS, Inductively Coupled Plasma Mass Spectrometry or Inductively Coupled Plasma Mass Spectrometer was used. The number of hit was 373 in 1994, 462 in 1995, and 356 as of September, 1996, 1191 in total. The cumulative number of the papers from 1980 to 1996 is shown. It is known how rapidly the ICP-MS has pervaded as the means of analysis. In order to cope with the enormous number of papers, this time, it was decided to do the review by limiting to the papers which were published in the main journals deeply related to analytical chemistry. As to the tendency in the last three years, it is summarized as how to overcome the spectrum interference and matrix effect in the ICP-MS and the trend of using the ICP-MS as the high sensitivity detector for separation techniques. The technical basic research of the ICP-MS on spectrum interference, sample introduction method and others and the analysis of living body samples are reported. (K.I.)

  7. High temperature liquid chromatography hyphenated with ESI-MS and ICP-MS detection for the structural characterization and quantification of halogen containing drug metabolites

    International Nuclear Information System (INIS)

    Vlieger, Jon S.B. de; Giezen, Mark J.N.; Falck, David; Tump, Cornelis; Heuveln, Fred van; Giera, Martin; Kool, Jeroen; Lingeman, Henk; Wieling, Jaap; Honing, Maarten; Irth, Hubertus; Niessen, Wilfried M.A.

    2011-01-01

    Highlights: → Hyphenation of high temperature liquid chromatography to ICP-MS and ESI-MS. → Structural characterization of kinase inhibitor metabolites with high resolution MS n experiments. → Quantification of drug metabolites with ICP-MS based on Iodine detection. → Significant changes in ESI-MS response after small structural changes. - Abstract: In this paper we describe the hyphenation of high temperature liquid chromatography with ICP-MS and ESI-MS for the characterization of halogen containing drug metabolites. The use of temperature gradients up to 200 deg. C enabled the separation of metabolites with low organic modifier content. This specific property allowed the use of detection methods that suffer from (significant) changes in analyte response factors as a function of the organic modifier content such as ICP-MS. Metabolites of two kinase inhibitors (SB-203580-Iodo and MAPK inhibitor VIII) produced by bacterial cytochrome P450 BM3 mutants and human liver microsomes were identified based on high resolution MS n data. Quantification was done using their normalized and elemental specific response in the ICP-MS. The importance of these kinds of quantification strategies is stressed by the observation that the difference of the position of one oxygen atom in a structure can greatly affect its response in ESI-MS and UV detection.

  8. Characterization of ["1"1C]Lu AE92686 as a PET radioligand for phosphodiesterase 10A in the nonhuman primate brain

    International Nuclear Information System (INIS)

    Yang, Kai-Chun; Stepanov, Vladimir; Amini, Nahid; Martinsson, Stefan; Takano, Akihiro; Halldin, Christer; Nielsen, Jacob; Bundgaard, Christoffer; Bang-Andersen, Benny; Grimwood, Sarah; Farde, Lars; Finnema, Sjoerd J.

    2017-01-01

    ["1"1C]Lu AE92686 is a positron emission tomography (PET) radioligand that has recently been validated for examining phosphodiesterase 10A (PDE10A) in the human striatum. ["1"1C]Lu AE92686 has high affinity for PDE10A (IC_5_0 = 0.39 nM) and may also be suitable for examination of the substantia nigra, a region with low density of PDE10A. Here, we report characterization of regional ["1"1C]Lu AE92686 binding to PDE10A in the nonhuman primate (NHP) brain. A total of 11 PET measurements, seven baseline and four following pretreatment with unlabeled Lu AE92686 or the structurally unrelated PDE10A inhibitor MP-10, were performed in five NHPs using a high resolution research tomograph (HRRT). ["1"1C]Lu AE92686 binding was quantified using a radiometabolite-corrected arterial input function and compartmental and graphical modeling approaches. Regional time-activity curves were best described with the two-tissue compartment model (2TCM). However, the distribution volume (V_T) values for all regions were obtained by the Logan plot analysis, as reliable cerebellar V_T values could not be derived by the 2TCM. For cerebellum, a proposed reference region, V_T values increased by ∝30 % with increasing PET measurement duration from 63 to 123 min, while V_T values in target regions remained stable. Both pretreatment drugs significantly decreased ["1"1C]Lu AE92686 binding in target regions, while no significant effect on cerebellum was observed. Binding potential (BP_N_D) values, derived with the simplified reference tissue model (SRTM), were 13-17 in putamen and 3-5 in substantia nigra and correlated well to values from the Logan plot analysis. The method proposed for quantification of ["1"1C]Lu AE92686 binding in applied studies in NHP is based on 63 min PET data and SRTM with cerebellum as a reference region. The study supports that ["1"1C]Lu AE92686 can be used for PET examinations of PDE10A binding also in substantia nigra. (orig.)

  9. Characterization of [{sup 11}C]Lu AE92686 as a PET radioligand for phosphodiesterase 10A in the nonhuman primate brain

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kai-Chun; Stepanov, Vladimir; Amini, Nahid; Martinsson, Stefan; Takano, Akihiro; Halldin, Christer [Karolinska Institutet, Karolinska University Hospital, Department of Clinical Neuroscience, Center for Psychiatric Research, Stockholm (Sweden); Nielsen, Jacob [H. Lundbeck A/S, Synaptic Transmission, Valby (Denmark); Bundgaard, Christoffer; Bang-Andersen, Benny [H. Lundbeck A/S, Discovery Chemistry and DMPK, Valby (Denmark); Grimwood, Sarah [Pfizer Inc., Neuroscience and Pain Research Unit, Cambridge, MA (United States); Farde, Lars [Karolinska Institutet, Karolinska University Hospital, Department of Clinical Neuroscience, Center for Psychiatric Research, Stockholm (Sweden); AstraZeneca PET Science Center at Karolinska Institutet, Personalized Health Care and Biomarkers, Stockholm (Sweden); Finnema, Sjoerd J. [Karolinska Institutet, Karolinska University Hospital, Department of Clinical Neuroscience, Center for Psychiatric Research, Stockholm (Sweden); Yale University, Department of Radiology and Biomedical Imaging, New Haven, CT (United States)

    2017-02-15

    [{sup 11}C]Lu AE92686 is a positron emission tomography (PET) radioligand that has recently been validated for examining phosphodiesterase 10A (PDE10A) in the human striatum. [{sup 11}C]Lu AE92686 has high affinity for PDE10A (IC{sub 50} = 0.39 nM) and may also be suitable for examination of the substantia nigra, a region with low density of PDE10A. Here, we report characterization of regional [{sup 11}C]Lu AE92686 binding to PDE10A in the nonhuman primate (NHP) brain. A total of 11 PET measurements, seven baseline and four following pretreatment with unlabeled Lu AE92686 or the structurally unrelated PDE10A inhibitor MP-10, were performed in five NHPs using a high resolution research tomograph (HRRT). [{sup 11}C]Lu AE92686 binding was quantified using a radiometabolite-corrected arterial input function and compartmental and graphical modeling approaches. Regional time-activity curves were best described with the two-tissue compartment model (2TCM). However, the distribution volume (V{sub T}) values for all regions were obtained by the Logan plot analysis, as reliable cerebellar V{sub T} values could not be derived by the 2TCM. For cerebellum, a proposed reference region, V{sub T} values increased by ∝30 % with increasing PET measurement duration from 63 to 123 min, while V{sub T} values in target regions remained stable. Both pretreatment drugs significantly decreased [{sup 11}C]Lu AE92686 binding in target regions, while no significant effect on cerebellum was observed. Binding potential (BP{sub ND}) values, derived with the simplified reference tissue model (SRTM), were 13-17 in putamen and 3-5 in substantia nigra and correlated well to values from the Logan plot analysis. The method proposed for quantification of [{sup 11}C]Lu AE92686 binding in applied studies in NHP is based on 63 min PET data and SRTM with cerebellum as a reference region. The study supports that [{sup 11}C]Lu AE92686 can be used for PET examinations of PDE10A binding also in substantia

  10. Power Consumption and Calculation Requirement Analysis of AES for WSN IoT.

    Science.gov (United States)

    Hung, Chung-Wen; Hsu, Wen-Ting

    2018-05-23

    Because of the ubiquity of Internet of Things (IoT) devices, the power consumption and security of IoT systems have become very important issues. Advanced Encryption Standard (AES) is a block cipher algorithm is commonly used in IoT devices. In this paper, the power consumption and cryptographic calculation requirement for different payload lengths and AES encryption types are analyzed. These types include software-based AES-CB, hardware-based AES-ECB (Electronic Codebook Mode), and hardware-based AES-CCM (Counter with CBC-MAC Mode). The calculation requirement and power consumption for these AES encryption types are measured on the Texas Instruments LAUNCHXL-CC1310 platform. The experimental results show that the hardware-based AES performs better than the software-based AES in terms of power consumption and calculation cycle requirements. In addition, in terms of AES mode selection, the AES-CCM-MIC64 mode may be a better choice if the IoT device is considering security, encryption calculation requirement, and low power consumption at the same time. However, if the IoT device is pursuing lower power and the payload length is generally less than 16 bytes, then AES-ECB could be considered.

  11. Online elemental analysis of process gases with ICP-OES: A case study on waste wood combustion

    International Nuclear Information System (INIS)

    Wellinger, Marco; Wochele, Joerg; Biollaz, Serge M.A.; Ludwig, Christian

    2012-01-01

    Highlights: ► Simultaneous measurements of 23 elements in process gases of a waste wood combustor. ► Mobile ICP spectrometer allows measurements of high quality at industrial plants. ► Continuous online measurements with high temporal resolution. ► Linear correlations among element concentrations in the raw flue gas were detected. ► Novel sampling and calibration methods for ICP-OES analysis of process gases. - Abstract: A mobile sampling and measurement system for the analysis of gaseous and liquid samples in the field was developed. An inductively coupled plasma optical emission spectrometer (ICP-OES), which is built into a van, was used as detector. The analytical system was calibrated with liquid and/or gaseous standards. It was shown that identical mass flows of either gaseous or liquid standards resulted in identical ICP-OES signal intensities. In a field measurement campaign trace and minor elements in the raw flue gas of a waste wood combustor were monitored. Sampling was performed with a highly transport efficient liquid quench system, which allowed to observe temporal variations in the elemental process gas composition. After a change in feedstock an immediate change of the element concentrations in the flue gas was detected. A comparison of the average element concentrations during the combustion of the two feedstocks showed a high reproducibility for matrix elements that are expected to be present in similar concentrations. On the other hand elements that showed strong differences in their concentration in the feedstock were also represented by a higher concentration in the flue gas. Following the temporal variations of different elements revealed strong correlations between a number of elements, such as chlorine with sodium, potassium and zinc, as well as arsenic with lead, and calcium with strontium.

  12. Feasibility of laser-induced breakdown spectroscopy (LIBS) for classification of sea salts.

    Science.gov (United States)

    Tan, Man Minh; Cui, Sheng; Yoo, Jonghyun; Han, Song-Hee; Ham, Kyung-Sik; Nam, Sang-Ho; Lee, Yonghoon

    2012-03-01

    We have investigated the feasibility of laser-induced breakdown spectroscopy (LIBS) as a fast, reliable classification tool for sea salts. For 11 kinds of sea salts, potassium (K), magnesium (Mg), calcium (Ca), and aluminum (Al), concentrations were measured by inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and the LIBS spectra were recorded in the narrow wavelength region between 760 and 800 nm where K (I), Mg (I), Ca (II), Al (I), and cyanide (CN) band emissions are observed. The ICP-AES measurements revealed that the K, Mg, Ca, and Al concentrations varied significantly with the provenance of each salt. The relative intensities of the K (I), Mg (I), Ca (II), and Al (I) peaks observed in the LIBS spectra are consistent with the results using ICP-AES. The principal component analysis of the LIBS spectra provided the score plot with quite a high degree of clustering. This indicates that classification of sea salts by chemometric analysis of LIBS spectra is very promising. Classification models were developed by partial least squares discriminant analysis (PLS-DA) and evaluated. In addition, the Al (I) peaks enabled us to discriminate between different production methods of the salts. © 2012 Society for Applied Spectroscopy

  13. Determination of {sup 90}Sr in soil samples using inductively coupled plasma mass spectrometry equipped with dynamic reaction cell (ICP-DRC-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Feuerstein, J.; Boulyga, S.F.; Galler, P.; Stingeder, G. [Department of Chemistry, Division of Analytical Chemistry-VIRIS Laboratory, University of Natural Resources and Applied Life Sciences, Muthgasse 18, A-1190 Vienna (Austria); Prohaska, T. [Department of Chemistry, Division of Analytical Chemistry-VIRIS Laboratory, University of Natural Resources and Applied Life Sciences, Muthgasse 18, A-1190 Vienna (Austria)], E-mail: thomas.prohaska@boku.ac.at

    2008-11-15

    A rapid method is reported for the determination of {sup 90}Sr in contaminated soil samples in the vicinity of the Chernobyl Nuclear Power Plant by ICP-DRC-MS. Sample preparation and measurement procedures focus on overcoming the isobaric interference of {sup 90}Zr, which is present in soils at concentrations higher by more than six orders of magnitude than {sup 90}Sr. Zirconium was separated from strontium in two steps to reduce the interference by {sup 90}Zr{sup +} ions by a factor of more than 10{sup 7}: (i) by ion exchange using a Sr-specific resin and (ii) by reaction with oxygen as reaction gas in a dynamic reaction cell (DRC) of a quadrupole ICP-MS. The relative abundance sensitivity of the ICP-MS was studied systematically and the peak tailing originating from {sup 88}Sr on mass 90 u was found to be about 3 x 10{sup -9}. Detection limits of 4 fg g{sup -1} (0.02 Bq g{sup -1}) were achieved when measuring Sr solutions containing no Zr. In digested uncontaminated soil samples after matrix separation as well as in a solution of 5 {mu}g g{sup -1} Sr and 50 ng g{sup -1} Zr a detection limit of 0.2 pg g{sup -1} soil (1 Bq g{sup -1} soil) was determined. {sup 90}Sr concentrations in three soil samples collected in the vicinity of the Chernobyl Nuclear Power Plant were 4.66 {+-} 0.27, 13.48 {+-} 0.68 and 12.9 {+-} 1.5 pg g{sup -1} corresponding to specific activities of 23.7 {+-} 1.3, 68.6 {+-} 3.5 and 65.6 {+-} 7.8 Bq g{sup -1}, respectively. The ICP-DRC-MS results were compared to the activities measured earlier by radiometry. Although the ICP-DRC-MS is inferior to commonly used radiometric methods with respect to the achievable minimum detectable activity it represents a time- and cost-effective alternative technique for fast monitoring of high-level {sup 90}Sr contamination in environmental or nuclear industrial samples down to activities of about 1 Bq g{sup -1}.

  14. Development of analytical procedures for determination of total chromium by quadrupole ICP-MS and high-resolution ICP-MS, and hexavalent chromium by HPLC-ICP-MS, in different materials used in the automotive industry.

    Science.gov (United States)

    Séby, F; Gagean, M; Garraud, H; Castetbon, A; Donard, O F X

    2003-10-01

    A European directive was recently adopted limiting the use of hazardous substances such as Pb, Hg, Cd, and Cr(VI) in vehicle manufacturing. From July 2003 a maximum of 2 g Cr(VI) will be authorised per vehicle in corrosion-preventing coatings of key components. As no standardised procedures are available to check if produced vehicles are in agreement with this directive, the objective of this work was to develop analytical procedures for total chromium and Cr(VI) determination in these materials. The first step of this study was to optimise digestion procedures for total chromium determination in plastic and metallic materials by inductively coupled plasma mass spectrometry (ICP-MS). High resolution (HR) ICP-MS was used to examine the influence of polyatomic interferences on the detection of the (52)Cr(+) and (53)Cr(+) isotopes. If there was strong interference with m/ z 52 for plastic materials, it was possible to use quadrupole ICP-MS for m/ z 53 if digestions were performed with HNO(3)+H(2)O(2). This mixture was also necessary for digestion of chromium from metallic materials. Extraction procedures in alkaline medium (NH(4)(+)/NH(3) buffer solution at pH 8.9) assisted by sonication were developed for determining Cr(VI) in four different corrosion-preventing coatings by HPLC-ICP-MS. After optimisation and validation with the only solid reference material certified for its Cr(VI) content (BCR 545; welding dusts), the efficiency of this extraction procedure for screw coatings was compared with that described in the EN ISO 3613 standard generally used in routine laboratories. For coatings comprising zinc and aluminium passivated in depth with chromium oxides the extraction procedure developed herein enabled determination of higher Cr(VI) concentrations. This was also observed for the screw covered with a chromium passivant layer on zinc-nickel. For coating comprising a chromium passivant layer on alkaline zinc the standardized extraction procedure was more efficient

  15. Determination of Rare Earth Elements in Thai Monazite by Inductively Coupled Plasma and Nuclear Analytical techniques

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Ratanapra, Dusadee; Sukharn, Sumalee; Laoharojanaphand, Sirinart

    2003-10-01

    The inductively coupled plasma atomic emission spectroscopy (ICP-AES) for the determination of individual rare-earth elements (REE) was evaluated by comparison with instrumental neutron activation analysis (INAA) and x-ray fluorescence spectrometry (XRF). The accuracy and precision of INAA and ICP-AES were evaluated by using standard reference material IGS-36, a monazite concentrate. For INAA, the results were close to the certified value while ICP-AES were in good agreement except for some low concentration rare earth. The techniques were applied for the analysis of some rare earth elements in two Thai monazite samples preparing as the in-house reference material for the Rare Earth Research and Development Center, Chemistry Division, Office of Atoms for Peace. The analytical results obtained by these techniques were in good agreement with each other

  16. Determination of {sup 241}Pu in nuclear waste slurries: A comparative study using LSC and ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Jaeggi, M., E-mail: maya.jaeggi@psi.ch [Department Logistics for Radiation Safety and Security, Radioanalytics, CH-5232 Villligen PSI (Switzerland); Roellin, S., E-mail: Stefan.Roellin@babs.admin.ch [Federal Office for Civil Protection, SPIEZ Laboratory, CH-3700 Spiez (Switzerland); Corcho Alvarado, J.A., E-mail: Corcho-Alvarado@chuv.ch [Institute of Radiation Physics, University Hospital and University of Lausanne, Rue du Grand-Pre 1, 1007 Lausanne (Switzerland); Eikenberg, J., E-mail: jost.eikenberg@psi.ch [Department Logistics for Radiation Safety and Security, Radioanalytics, CH-5232 Villligen PSI (Switzerland)

    2012-02-15

    {sup 241}Pu was determined in slurry samples from a nuclear reactor decommissioning project at the Paul Scherrer Institute (Switzerland). To validate the results, the {sup 241}Pu activities of five samples were determined by LSC (TriCarb and Quantulus) and ICP-MS, with each instrument at a different laboratory. In lack of certified reference materials for {sup 241}Pu, the methods were further validated using the {sup 241}Pu information values of two reference sediments (IAEA-300 and IAEA-384). Excellent agreement with the results was found between LSC and ICP-MS in the nuclear waste slurries and the reference sediments. - Highlights: Black-Right-Pointing-Pointer Good agreement between the {sup 241}Pu activity of 5 slurry samples, using 3 measurement techniques. Black-Right-Pointing-Pointer {sup 241}Pu information values of two IAEA samples agreed well for the 3 measurement techniques. Black-Right-Pointing-Pointer Low detection limits were achieved; 1.8 Bq/kg (Quantulus), 2 Bq/kg (ICP-MS) and 3.5 Bq/kg (TriCarb).

  17. Laser ablation ICP-MS for quantitative biomedical applications

    International Nuclear Information System (INIS)

    Konz, Ioana; Fernandez, Beatriz; Fernandez, M.L.; Pereiro, Rosario; Sanz-Medel, Alfredo

    2012-01-01

    LA-ICP-MS allows precise, relatively fast, and spatially resolved measurements of elements and isotope ratios at trace and ultratrace concentration levels with minimal sample preparation. Over the past few years this technique has undergone rapid development, and it has been increasingly applied in many different fields, including biological and medical research. The analysis of essential, toxic, and therapeutic metals, metalloids, and nonmetals in biomedical tissues is a key task in the life sciences today, and LA-ICP-MS has proven to be an excellent complement to the organic MS techniques that are much more commonly employed in the biomedical field. In order to provide an appraisal of the fast progress that is occurring in this field, this review critically describes new developments for LA-ICP-MS as well as the most important applications of LA-ICP-MS, with particular emphasis placed on the quantitative imaging of elements in biological tissues, the analysis of heteroatom-tagged proteins after their separation and purification by gel electrophoresis, and the analysis of proteins that do not naturally have ICP-MS-detectable elements in their structures, thus necessitating the use of labelling strategies. (orig.)

  18. Calibration and correction of LA-ICP-MS and LA-MC-ICP-MS analyses for element contents and isotopic ratios

    Directory of Open Access Journals (Sweden)

    Jie Lin

    2016-06-01

    Full Text Available LA-ICP-MS and LA-MC-ICP-MS have been the techniques of choice for achieving accurate and precise element content and isotopic ratio, the state-of-the-art technique combines the advantages of low detection limits with high spatial resolution, however, the analysis accuracy and precision are restricted by many factors, such as sensitivity drift, elemental/isotopic fractionation, matrix effects, interferences and the lack of sufficiently matrix-matched reference materials. Thus, rigorous and suitable calibration and correction methods are needed to obtain quantitative data. This review systematically summarized and evaluated the interference correction, quantitative calculation and sensitivity correction strategies in order to provide the analysts with suitable calibration and correction strategies according to the sample types and the analyzed elements. The functions and features of data reduction software ICPMSDataCal were also outlined, which can provide real-time and on-line data reduction of element content and isotopic ratios analyzed by LA-ICP-MS and LA-MC-ICP-MS.

  19. Uranium isotopic ratio measurements ({sup 235}U/{sup 238}U) by laser ablation high resolution inductively coupled plasma mass spectrometry for environmental radioactivity monitoring - {sup 235}U/{sup 238}U isotope ratio analysis by LA-ICP-MS-HR for environmental radioactivity monitoring

    Energy Technology Data Exchange (ETDEWEB)

    David, K.; Mokili, M.B.; Rousseau, G.; Deniau, I.; Landesman, C. [SUBATECH, Ecole des Mines de Nantes, Universite de Nantes, CNRS/IN2P3, 4 rue Alfred Kastler, 44307 Nantes cedex 3 (France)

    2014-07-01

    The protection of the aquatic and terrestrial environments from a broad range of contaminants spread by nuclear activities (nuclear plants, weapon tests or mining) require continuous monitoring of long-lives radionuclides that were released into the environment. The precise determination of uranium isotope ratios in both natural and potential contaminated samples is of primary concern for the nuclear safeguards and the control of environmental contamination. As an example, analysis of environmental samples around nuclear plants are carried out to detect the traces in the environment originating from nuclear technology activities. This study deals with the direct analysis of {sup 235}U/{sup 238}U isotope ratios in real environmental solid samples performed with laser ablation (LA)-HR-ICP-MS. A similar technique has already been reported for the analysis of biological samples or uranium oxide particles [1,2] but to our knowledge, this was never applied on real environmental samples. The high sensitivity, rapid acquisition time and low detection limits are the main advantages of high resolution ICP-MS for accurate and precise isotope ratio measurements of uranium at trace and ultra-trace levels. In addition, the use of laser ablation allows the analysis of solid samples with minimal preparation. A a consequence, this technique is very attractive for conducting rapid direct {sup 235}U/{sup 238}U isotope ratio analysis on a large set of various matrix samples likely to be encountered in environmental monitoring such as corals, soils, sands, sediments, terrestrial and marine bio-indicators. For the present study, LA-ICP-MS-HR analyses are performed using a New Wave UP213 nano-second Nd:YAG laser coupled to a Thermo Element-XR high resolution mass spectrometer. Powdered samples are compacted with an hydraulic press (5 tons) in order to obtain disk-shaped pellet (10-13 mm in diameter and 2 mm in thickness). The NIST612 reference glass is used for LA-ICP-MS-HR tuning and as

  20. {sup 99}Tc bioassay by inductively coupled plasma mass spectrometry (ICP-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, L.A.

    1998-05-01

    A means of analyzing {sup 99}Tc in urine by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. Historically, {sup 99}Tc analysis was based on the radiometric detection of the 293 keV E{sub Max} beta decay product by liquid scintillation or gas flow proportional counting. In a urine matrix, the analysis of{sup 99}Tc is plagued with many difficulties using conventional radiometric methods. Difficulties originate during chemical separation due to the volatile nature of Tc{sub 2}O{sub 7} or during radiation detection due to color or chemical quenching. A separation scheme for {sup 99}Tc detection by ICP-MS is given and is proven to be a sensitive and robust analytical alternative. A comparison of methods using radiometric and mass quantitation of {sup 99}Tc has been conducted in water, artificial urine, and real urine matrices at activity levels between 700 and 2,200 dpm/L. Liquid scintillation results based on an external standard quench correction and a quench curve correction method are compared to results obtained by ICP-MS. Each method produced accurate results, however the precision of the ICP-MS results is superior to that of liquid scintillation results. Limits of detection (LOD) for ICP-MS and liquid scintillation detection are 14.67 and 203.4 dpm/L, respectively, in a real urine matrix. In order to determine the basis for the increased precision of the ICP-MS results, the detection sensitivity for each method is derived and measured. The detection sensitivity for the {sup 99}Tc isotope by ICP-MS is 2.175 x 10{sup {minus}7} {+-} 8.990 x 10{sup {minus}9} and by liquid scintillation is 7.434 x 10{sup {minus}14} {+-} 7.461 x 10{sup {minus}15}. A difference by seven orders of magnitude between the two detection systems allows ICP-MS samples to be analyzed for a period of 15 s compared to 3,600 s by liquid scintillation counting with a lower LOD.

  1. Comparison between INAA and ICP-OES: analysis of Sudanese medicinal plants

    International Nuclear Information System (INIS)

    Sheikhaldin, Elsadig Abdelmoniem

    2014-07-01

    The aim of this study was to provide elemental concentrations in medicinal plants and mainly to compare the two different determination methods (INAA and ICP-OES after wet digestion) elemental analysis of 14 Sudanese medicinal plants was carried out using INAA and ICP-OES techniques. The selection of reported elements was done according to intersection of elements determined by both techniques. This intersecting element list contained Ca, K, Fe, Mn, Mg, Sr, Zn, Cu, Co, and Cr. INAA correlated well with ICP-OES measurements of the same plants as long as concentrations were sufficiently above LoQ. Correlation coefficients (R 2 ) in this case is close to 1. Generally, INAA results tended to be higher compared to ICP-OES. The performance and possible source of errors of both techniques was discussed also with respect to measurements of certified reference materials. INAA provided the advantage of having both, faster and non destructive sample preparation than ICP-OES. Therefore, INAA may be technique of choice for Ca, K, Zn, and Mg elements specifically when samples are needed for further investigations. Regarding the low concentrations e.g for Cr, Ni or Cu, ICP-OES is the superior technique over INAA due to the sufficiently low limits of determination and thus gaining more detectable results at low concentrations. (author)

  2. Accomplishments: AE characterization program for remote flaw evaluation

    International Nuclear Information System (INIS)

    Hutton, P.H.; Schwenk, E.B.; Kurtz, R.J.

    1978-01-01

    The purpose of the program is to develop an experimental/analytical evaluation of the feasibility of detecting and analyzing flaw growth in reactor pressure boundaries by means of continuously monitoring acoustic emission (AE). The investigation is devoted exclusively to ASTM Type A533, Grade B, Class 1 material. The basic approach to interpretive model development is through laboratory testing of 1 to 1 1 / 2 inch (25.4 to 38 mm) thick fracture mechanics specimens in both fatigue and fracture at both room temperature and 550 0 F (288 0 C). Seven parameters are measured for each AE signal and related to fracture mechanics functions. AE data from fracture testing of 6 inch (152 mm) wall pressure vessels are also incorporated in analysis

  3. Fundamental and applied measurements in ICP MS

    International Nuclear Information System (INIS)

    Carter, Julian Robert

    2002-01-01

    Fundamental and applied aspects of ICP-MS have been investigated to gain an increased understanding of the technique and improve on its analytical capabilities. Dissociation temperatures of polyatomic ions were calculated using a double-focusing sector instrument, to obtain more reliable mass spectral data with controlled vapour introduction via a Dreschel bottle to allow accurate calculation of the ingredients in the plasma. The equilibrium temperature for the plasma, operated at 1280 W calculated using CO + and C 2 + as the thermometric probes, was c.a. 5800 - 7400 K, while using ArO + and ArC + as the thermometric probes the temperature calculated was c.a. 2000 - 7000 K. Calculated dissociation temperatures were used to elucidate the site of formation of these ions. Results confirmed that strongly bound ions such as CO + and C 2 + were formed in the plasma whereas weakly bound ions such as ArO + and ArC + were formed in the interface region due to gross deviation of the calculated temperatures from those expected for a system in thermal equilibrium. The use of helium gas in a hexapole collision cell attenuated the signals of ArH + Ar + , ArO + , ArC + , ArCl + and Ar 2 + allowing improved determination of 39 K + , 40 Ca + , 56 Fe + , 52 Cr + , 75 As + and 80 Se + in standard solutions. The use of the hexapole collision cell also resulted in an enhancement of analyte signals due to the thermalisation of the ion beam. The ion kinetic energy of ions sampled from the plasma and those sampled from the skimmer cone were determined using a modified lens stack to assess the significance for memory effects of material deposited on the skimmer cone. The most probable kinetic energy of Be + ions sampled from the skimmer cone was found to be 2.4 eV, which was considerably lower than the most probable kinetic energy of Be + ions sampled from the plasma, which was found to be 9.5 eV. The low kinetic energy of the ions deposited on the skimmer cone means they will only

  4. Relocation of the disulfonic stilbene sites of AE1 (band 3) on the basis of fluorescence energy transfer measurements.

    Science.gov (United States)

    Knauf, Philip A; Law, Foon-Yee; Leung, Tze-Wah Vivian; Atherton, Stephen J

    2004-09-28

    Previous fluorescence resonance energy transfer (FRET) measurements, using BIDS (4-benzamido-4'-isothiocyanostilbene-2,2'-disulfonate) as a label for the disulfonic stilbene site and FM (fluorescein-5-maleimide) as a label for the cytoplasmic SH groups on band 3 (AE1), combined with data showing that the cytoplasmic SH groups lie about 40 A from the cytoplasmic surface of the lipid bilayer, would place the BIDS sites very near the membrane's inner surface, a location that seems to be inconsistent with current models of AE1 structure and mechanism. We reinvestigated the BIDS-FM distance, using laser single photon counting techniques as well as steady-state fluorescence of AE1, in its native membrane environment. Both techniques agree that there is very little energy transfer from BIDS to FM. The mean energy transfer (E), based on three-exponential fits to the fluorescence decay data, is 2.5 +/- 0.7% (SEM, N = 12). Steady-state fluorescence measurements also indicate BIDS to FM. These data indicate that the BIDS sites are probably over 63 A from the cytoplasmic SH groups, placing them near the middle or the external half of the lipid bilayer. This relocation of the BIDS sites fits with other evidence that the disulfonic stilbene sites are located farther toward the external membrane surface than Glu-681, a residue near the inner membrane surface whose modification affects the pH dependence and anion selectivity of band 3. The involvement of two relatively distant parts of the AE1 protein in transport function suggests that the transport mechanism requires coordinated large-scale conformational changes in the band 3 protein.

  5. Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g{sup -1} levels

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F.; Tibi, Markus; Heumann, Klaus G. [Institute of Inorganic Chemistry and Analytical Chemistry, Johannes Gutenberg-University Mainz, Duesbergweg 10-14, 55099, Mainz (Germany)

    2004-01-01

    The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3 x 10{sup -13} g g{sup -1} for Pu isotopes in soil samples containing uranium at a concentration of a few {mu}g g{sup -1}. The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH{sup +} and PbO{sub 2}{sup +} ions and by the peak tail of {sup 238}U{sup +} ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of {alpha}-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of {sup 239+240}Pu (9.8{+-}3.0 mBq g{sup -1}) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4{+-}0.2 mBq g{sup -1}. However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if ''hot'' particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples. (orig.)

  6. High accuracy determination of trace elements in NIST standard reference materials by isotope dilution ICP-MS

    International Nuclear Information System (INIS)

    Paulsen, P.J.; Beary, E.S.

    1996-01-01

    At NIST (National Institute of Standards and Technology), ICP-MS ID (inductively coupled mass spectrometry isotope dilution) has been used to certify a wide range of elements in a variety of materials with high accuracy. Both the chemical preparation and instrumental procedures are simpler than with other ID mass spectrometric techniques. The ICP-MS has picogram/ml detection limits for most elements using fixed operating parameters. Chemical separations are required only to remove an interference (from molecular ions as well as isobaric atoms), or to pre-concentrate the analyte. For example, chemical separations were required for the analysis of SRM 2711, Montana II Soil, but not for boron in peach leaves, SRM 1547.(3 refs., 3 tabs., 2 figs

  7. Simultaneous measurement of 239Pu, 240Pu, 241Pu, and 242Pu by high resolution inductively coupled plasma mass spectrometer (HR ICP-MS) in marine sediments

    International Nuclear Information System (INIS)

    Bruneau, F.

    1999-01-01

    Transuranics elements are of particular interest in radioecological studies because of their radiotoxicity and their potential use to decipher source fingerprints and transport processes. The simultaneous measurement of 239 Pu, 240 Pu, 241 Pu, and 242 Pu in environmental samples requires a specific chemical procedure. This work deals with an analytical procedure which yields a very high grade of purification of Pu suitable for ultra low level detection by HR ICP-MS, from marine sediments. After the elimination of major elements (Fe, Al, Mg...) by a first chromatographic separation, a new device of purification by solvent extraction and concentration by a second chromatographic separation is used to obtain a concentrated and high purified solution of plutonium. The chemical procedure have been validated on IAEA certified sediment samples and on sediment samples collected in the roads of Cherbourg which had been previously analysed by other techniques (a spectrometry and thermo-ionisation mass spectrometer). (author)

  8. Quench detection/protection of an HTS coil by AE signals

    International Nuclear Information System (INIS)

    Yoneda, M.; Nanato, N.; Aoki, D.; Kato, T.; Murase, S.

    2011-01-01

    A quench detection/protection system based on measuring AE signals was developed. The system was tested for a Bi2223 coil. Temperature rise after a quench occurrence was restrained at very low value. The normal zone propagation velocities in high T c superconductors are slow at high operation temperature and therefore local and excessive temperature rise generates at quench occurrence, and then the superconductors are degraded or burned. Therefore it is essential to detect the temperature rise in high T c superconducting (HTS) coils as soon as possible and protect them. The authors have presented a quench detection method for HTS coils by time-frequency visualization of AE signals and have shown its usefulness for a HTS coil with height and outer diameter of 40-50 mm. In this paper, the authors present a quench detection/protection system based on superior method in quench detection time to the previous method and show its usefulness for a larger HTS coil (height and outer diameter: 160-190 mm) than the previous coil.

  9. A New Multielement Method for LA-ICP-MS Data Acquisition from Glacier Ice Cores.

    Science.gov (United States)

    Spaulding, Nicole E; Sneed, Sharon B; Handley, Michael J; Bohleber, Pascal; Kurbatov, Andrei V; Pearce, Nicholas J; Erhardt, Tobias; Mayewski, Paul A

    2017-11-21

    To answer pressing new research questions about the rate and timing of abrupt climate transitions, a robust system for ultrahigh-resolution sampling of glacier ice is needed. Here, we present a multielement method of LA-ICP-MS analysis wherein an array of chemical elements is simultaneously measured from the same ablation area. Although multielement techniques are commonplace for high-concentration materials, prior to the development of this method, all LA-ICP-MS analyses of glacier ice involved a single element per ablation pass or spot. This new method, developed using the LA-ICP-MS system at the W. M. Keck Laser Ice Facility at the University of Maine Climate Change Institute, has already been used to shed light on our flawed understanding of natural levels of Pb in Earth's atmosphere.

  10. Forensic analysis of tempered sheet glass by particle induced X-ray emission (PIXE)

    Energy Technology Data Exchange (ETDEWEB)

    Jisonna, L.J. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); DeYoung, P.A., E-mail: deyoung@hope.ed [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Ferens, J.; Hall, C.; Lunderberg, J.M.; Mears, P. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Padilla, D. [Department of Physics, San Diego State University, San Diego, CA 92182-1233 (United States); Peaslee, G.F. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Sampson, R. [Department of Physics, Columbia University, New York, NY 10027 (United States)

    2011-05-15

    Highlights: {yields} PIXE was found to give the same results for trace elements in glass as ICP. {yields} PIXE can non-destructively determine trace element concentrations in auto glass. {yields} Measured Ca, Fe, Ti, Mn, and Sr in auto glass with PIXE. -- Abstract: The elemental concentrations of five trace elements in tempered sheet glass fragments were determined using particle-induced X-ray emission (PIXE) spectrometry. The trace element concentrations for calcium, iron, manganese, strontium, and titanium are compared to those obtained by inductively-coupled plasma-atomic emission spectrometry (ICP-AES) following complete digestion by hydrofluoric acid. For these five elements, the absolute concentrations obtained by both methods are shown to agree well over a wide range of concentrations. The limits of detection for trace elements are typically lower for the ICP-AES method. However, we show that the concentrations of these five elements can be accurately measured by the PIXE method. Since PIXE is an entirely non-destructive method, there exists a niche for this technique to be used as a complement to the more sensitive ICP-AES technique in the forensic analysis of sheet glass.

  11. Gold nanoparticle labeling with tyramide signal amplification for highly sensitive detection of alpha fetoprotein in human serum by ICP-MS.

    Science.gov (United States)

    Li, Xiaoting; Chen, Beibei; He, Man; Xiao, Guangyang; Hu, Bin

    2018-01-01

    In this work, we developed an immunoassay based on tyramide signal amplification (TSA) and gold nanoparticles (Au NPs) labeling for highly sensitive detection of alpha fetoprotein (AFP) by inductively coupled plasma mass spectrometry (ICP-MS). AFP was captured by anti-AFP1 coating on the 96-well plate and labeled by anti-AFP2-horseradish peroxidase (HRP), in which the HRP can catalyze the deposition of biotinylated tyramine on the nearby protein. Then the streptavidin (SA)-Au NPs was labeled on the deposited biotinylated tyramine as the intensive signal probe for ICP-MS measurement. Under the optimal experimental conditions, the limit of detection of the developed method for AFP was 1.85pg/mL and the linear range was 0.005-2ng/mL. The relative standard deviation for seven replicate detections of 0.01ng/mL AFP was 5.2%. The proposed method was successfully applied to the detection of AFP in human serum with good recoveries. This strategy is highly sensitive and easy to operate, and can be extended to the sensitive detection of other biomolecules in human serum. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Gas-phase sample introduction techniques for the determination of some non-metals by ICP-AES, MIP-AES AND ICP-MS

    International Nuclear Information System (INIS)

    Nakahara, Taketoshi

    2003-01-01

    Various gas-phase sample introduction methods in analytical atomic spectrometry have been documented for up to 30 elements, but only a few of these methods with less than one-third of the analytes exhibit adequate, competitive performance characteristics. Most attractive are the chemical systems based on (i) reactions in aqueous media, (ii) with fast kinetics of chemical vapor generation and easy stripping off of vapors from solution, (iii) reliable interference control, (iv) with high and reducible chemical yields of volatile products which are (v) readily atomized, excited or ionized in a plasma, so as to provide adequate sensitivity and low limits of detection (LOD). Some significant advantage of gas-phase sample introduction over the widely-used pneumatic nebulization of liquid (solution) samples are (1) high chemical yields and transport efficiency, (2) separation from troublesome matrices, (3) enrichment, (4) automation in flow injection and continuous flow mode, (5) good sample throughput rates, (6) competitive LODs and RSDs, (7) commercially available accessories, (8) economically affordable and (9) speciation potentialities. To the contrary, the major disadvantages and limitations are (1) complex, on line-chemistry involved, (2) specific sample pre-treatment required, (3) effect of oxidation and binding state of analyte, (4) chemical interferences, (5) foaming and aerosol formation, (6) numerous instrumental and chemical parameters for optimization, (7) applicability to a limited number of analytes, (8) limited linear ranges and (9) poor-multi-element capabilities.

  13. Analytical applications of ICP-FTS

    International Nuclear Information System (INIS)

    Faires, L.M.; Palmer, B.A.; Cunningham, P.T.

    1986-01-01

    The Analytical Chemistry Group of the Chemistry Division at Los Alamos National Laboratory has been investigating the analytical utility of the inductively coupled plasma (ICP) - Fourier transform spectrometer (FTS) combination. While a new state-of-the-art FTS facility is under construction at Los Alamos, preliminary data has been obtained on the one-meter FTS at the National Solar Observatory at Kitt Peak, Arizona. This paper presents an update of the Los Alamos FTS facility, which is expected to be completed in 1986, and presents data showing the analytical potential of an ICP-FTS system. Some of the potential problems of the multiplex disadvantage are discussed, and the advantages of the high resolution obtainable with the FTS are illustrated

  14. Beta activity measurements in high, variable gamma backgrounds

    International Nuclear Information System (INIS)

    Stanga, D.; Sandu, E.; Craciun, L.

    1997-01-01

    In many cases beta activity measurements must be performed in high and variable gamma backgrounds. In such instances it is necessary to use well-shielded detectors but this technique is limited to laboratory equipment and frequently insufficient. In order to perform in a simple manner beta activity measurements in high and variable backgrounds a software-aided counting technique have been developed and a counting system have been constructed. This technique combines the different counting techniques with traditional method of successive measurement of the sample and background. The counting system is based on a programmable multi-scaler which is endowed with appropriate software and allow all operations to be performed via keyboard in an interactive fashion. Two large - area proportional detectors were selected in order to have the same background and the same gamma response within 5%. A program has been developed for the counting data analysis and beta activity computing. The software-aided counting technique has been implemented for beta activity measurement in high and variable backgrounds. (authors)

  15. Evaluation of measurement reproducibility using the standard-sites data, 1994 Fernald field characterization demonstration project

    International Nuclear Information System (INIS)

    Rautman, C.A.

    1996-02-01

    The US Department of Energy conducted the 1994 Fernald (Ohio) field characterization demonstration project to evaluate the performance of a group of both industry-standard and proposed alternative technologies in describing the nature and extent of uranium contamination in surficial soils. Detector stability and measurement reproducibility under actual operating conditions encountered in the field is critical to establishing the credibility of the proposed alternative characterization methods. Comparability of measured uranium activities to those reported by conventional, US Environmental Protection Agency (EPA)-certified laboratory methods is also required. The eleven (11) technologies demonstrated included (1) EPA-standard soil sampling and laboratory mass-spectroscopy analyses, and currently-accepted field-screening techniques using (2) sodium-iodide scintillometers, (3) FIDLER low-energy scintillometers, and (4) a field-portable x-ray fluorescence spectrometer. Proposed advanced characterization techniques included (5) alpha-track detectors, (6) a high-energy beta scintillometer, (7) electret ionization chambers, (8) and (9) a high-resolution gamma-ray spectrometer in two different configurations, (10) a field-adapted laser ablation-inductively coupled plasma-atomic emission spectroscopy (ICP-AES) technique, and (11) a long-range alpha detector. Measurement reproducibility and the accuracy of each method were tested by acquiring numerous replicate measurements of total uranium activity at each of two ''standard sites'' located within the main field demonstration area. Meteorological variables including temperature, relative humidity. and 24-hour rainfall quantities were also recorded in conjunction with the standard-sites measurements

  16. Analytic of elements for the determination of soil->plant transfer factors

    International Nuclear Information System (INIS)

    Liese, T.

    1985-02-01

    This article describes a part of the conventional analytical work, which was done to determine soil to plant transfer factors. The analytical methods, the experiments to find out the best way of sample digestion and the resulting analytical procedures are described. Analytical methods are graphite furnace atomic absorption spectrometry (GFAAS) and inductively coupled plasma atomic emission spectrometry (ICP-AES). In case of ICP-AES the necessity of right background correction and correction of the spectral interferences is shown. The reliability of the analytical procedure is demonstrated by measuring different kinds of standard reference materials and by comparison of AAS and AES. (orig./HP) [de

  17. Effect of postural changes on ICP in healthy and ill subjects

    DEFF Research Database (Denmark)

    Petersen, Lonnie G; Juhler, Marianne

    2015-01-01

    to distinguish normal human physiology from disease entities such as idiopathic intracranial hypertension and normal pressure hydrocephalus, we investigated ICP in different body postures in both normal and ill subjects. METHODS: Thirty-one patients were included: four normal patients following complete removal......: upright standing, sitting in a chair, supine and right lateral lumbar puncture position. RESULTS: Linear regression of median ICP based on patient posture, group, and purpose of monitoring presented a significant model (p ... of differences in median ICP between body postures and supine ICP as the baseline, presented a highly significant model (p posture (p postures enabled...

  18. Biclique cryptanalysis of the full AES

    DEFF Research Database (Denmark)

    Bogdanov, Andrey; Khovratovich, Dmitry; Rechberger, Christian

    2011-01-01

    Since Rijndael was chosen as the Advanced Encryption Standard (AES), improving upon 7-round attacks on the 128-bit key variant (out of 10 rounds) or upon 8-round attacks on the 192/256-bit key variants (out of 12/14 rounds) has been one of the most difficult challenges in the cryptanalysis of block...... ciphers for more than a decade. In this paper, we present the novel technique of block cipher cryptanalysis with bicliques, which leads to the following results: The first key recovery method for the full AES-128 with computational complexity 2126.1. The first key recovery method for the full AES-192...... with computational complexity 2189.7. The first key recovery method for the full AES-256 with computational complexity 2254.4. Key recovery methods with lower complexity for the reduced-round versions of AES not considered before, including cryptanalysis of 8-round AES-128 with complexity 2124.9. Preimage search...

  19. Lead isotope ratios in lichen samples evaluated by ICP-ToF-MS to assess possible atmospheric pollution sources in Havana, Cuba.

    Science.gov (United States)

    Alvarez, Alfredo Montero; Estévez Alvarez, Juan R; do Nascimento, Clístenes Williams Araújo; González, Iván Pupo; Rizo, Oscar Díaz; Carzola, Lázaro Lima; Torres, Roberto Ayllón; Pascual, Jorge Gómez

    2017-01-01

    Epiphytic lichens, collected from 119 sampling sites grown over "Roistonea Royal Palm" trees, were used to assess the spatial distribution pattern of lead (Pb) and identify possible pollution sources in Havana (Cuba). Lead concentrations in lichens and topsoils were determined by flame atomic absorption spectrophotometry and inductively coupled plasma (ICP) atomic emission spectrometry, respectively, while Pb in crude oils and gasoline samples were measured by ICP-time of flight mass spectrometry (ICP-ToF-MS). Lead isotopic ratios measurements for lichens, soils, and crude oils were obtained by ICP-ToF-MS. We found that enrichment factors (EF) reflected a moderate contamination for 71% of the samples (EF > 10). The 206 Pb/ 207 Pb ratio values for lichens ranged from 1.17 to 1.20 and were a mixture of natural radiogenic and industrial activities (e.g., crude oils and fire plants). The low concentration of Pb found in gasoline (leaded gasoline is no longer used in Cuba.

  20. Fundamental and applied measurements in ICP MS

    Energy Technology Data Exchange (ETDEWEB)

    Carter, Julian Robert

    2002-07-01

    Fundamental and applied aspects of ICP-MS have been investigated to gain an increased understanding of the technique and improve on its analytical capabilities. Dissociation temperatures of polyatomic ions were calculated using a double-focusing sector instrument, to obtain more reliable mass spectral data with controlled vapour introduction via a Dreschel bottle to allow accurate calculation of the ingredients in the plasma. The equilibrium temperature for the plasma, operated at 1280 W calculated using CO{sup +} and C{sub 2}{sup +} as the thermometric probes, was c.a. 5800 - 7400 K, while using ArO{sup +} and ArC{sup +} as the thermometric probes the temperature calculated was c.a. 2000 - 7000 K. Calculated dissociation temperatures were used to elucidate the site of formation of these ions. Results confirmed that strongly bound ions such as CO{sup +} and C{sub 2}{sup +} were formed in the plasma whereas weakly bound ions such as ArO{sup +} and ArC{sup +} were formed in the interface region due to gross deviation of the calculated temperatures from those expected for a system in thermal equilibrium. The use of helium gas in a hexapole collision cell attenuated the signals of ArH{sup +} Ar{sup +}, ArO{sup +}, ArC{sup +}, ArCl{sup +} and Ar{sub 2}{sup +} allowing improved determination of {sup 39}K{sup +}, {sup 40}Ca{sup +}, {sup 56}Fe{sup +}, {sup 52}Cr{sup +}, {sup 75}As{sup +} and {sup 80}Se{sup +} in standard solutions. The use of the hexapole collision cell also resulted in an enhancement of analyte signals due to the thermalisation of the ion beam. The ion kinetic energy of ions sampled from the plasma and those sampled from the skimmer cone were determined using a modified lens stack to assess the significance for memory effects of material deposited on the skimmer cone. The most probable kinetic energy of Be{sup +} ions sampled from the skimmer cone was found to be 2.4 eV, which was considerably lower than the most probable kinetic energy of Be{sup +} ions

  1. Chemical spots on the surface of the strongly magnetic Herbig Ae star HD 101412

    DEFF Research Database (Denmark)

    Järvinen, S. P.; Hubrig, S.; Schöller, M.

    2016-01-01

    Due to the knowledge of the rotation period and the presence of a rather strong surface magnetic field, the sharp-lined young Herbig Ae star HD 101412 with a rotation period of 42 d has become one of the most well-studied targets among the Herbig Ae stars. High-resolution HARPS polarimetric spectra...... that is opposite to the behaviour of the other elements studied. Since classical Ap stars usually show a relationship between the magnetic field geometry and the distribution of element spots, we used in our magnetic field measurements different line samples belonging to the three elements with the most numerous...

  2. Ir and Rare Earth's Elements determination by Neutron Activation Analysis and ICP - MS in soil samples

    Science.gov (United States)

    Salvini, A.; Cattadori, C.; Broggini, C.; Cagnazzo, M.; Ori, Gian Gabriele; Nisi, S.; Borio, A.; Manera, S.

    2006-05-01

    The platinum metals depleted in the earth's crust are relative to their cosmic abundance; concentration of these elements in sediments may thus indicate influxes of extraterrestrial material. Analysis of these parameters are done easily by Neutron Activation Analysis (NAA) and comparative results with ICP-MS technique show a good match. Results, adjust parameters and limits of this method will be displayed in tables.

  3. Classifying wine according to geographical origin via quadrupole-based ICP-mass spectrometry measurements of boron isotope ratios

    Energy Technology Data Exchange (ETDEWEB)

    Coetzee, Paul P. [University of Johannesburg, Department of Chemistry, Johannesburg (South Africa); Vanhaecke, Frank [Institute for Nuclear Sciences, Laboratory of Analytical Chemistry Ghent University, Ghent (Belgium)

    2005-11-01

    The potential of quadrupole-based ICP-MS as a tool for B-isotopic analysis of wines and its usefulness in provenance determinations were assessed. A precision of 0.1-0.25% RSD (corresponding to a relative standard deviation of the mean of three replicate measurements of 0.06-0.12%) was sufficient to establish small differences in the B isotope ratios in wines from different geographical origins. Each sample measurement was bracketed by measurements of a standard and mass bias drift correction made by interpolation. Sample preparation was kept to a minimum to avoid possible fractionation. Dilution of the wine samples by a factor of 100 with 0.65% HNO{sub 3} was found to reduce matrix-induced mass discrimination substantially. Wines from three wine-producing regions, Stellenbosch, Robertson, and Swartland, in the Western Cape Province of South Africa, and wines from specific regions in France (Bergerac) and Italy (Valpolicella) were analyzed by ICP-QMS for their B-isotopic compositions. It was concluded that the {sup 11}B/{sup 10}B ratios can be used to characterize wines from different geographical origins. Average {sup 11}B/{sup 10}B ratios in red wines from South Africa (Stellenbosch), France (Bergerac), and Italy (Valpolicella) were found to differ by between 0.5 and 1.5%. (orig.)

  4. Classifying wine according to geographical origin via quadrupole-based ICP-mass spectrometry measurements of boron isotope ratios

    International Nuclear Information System (INIS)

    Coetzee, Paul P.; Vanhaecke, Frank

    2005-01-01

    The potential of quadrupole-based ICP-MS as a tool for B-isotopic analysis of wines and its usefulness in provenance determinations were assessed. A precision of 0.1-0.25% RSD (corresponding to a relative standard deviation of the mean of three replicate measurements of 0.06-0.12%) was sufficient to establish small differences in the B isotope ratios in wines from different geographical origins. Each sample measurement was bracketed by measurements of a standard and mass bias drift correction made by interpolation. Sample preparation was kept to a minimum to avoid possible fractionation. Dilution of the wine samples by a factor of 100 with 0.65% HNO 3 was found to reduce matrix-induced mass discrimination substantially. Wines from three wine-producing regions, Stellenbosch, Robertson, and Swartland, in the Western Cape Province of South Africa, and wines from specific regions in France (Bergerac) and Italy (Valpolicella) were analyzed by ICP-QMS for their B-isotopic compositions. It was concluded that the 11 B/ 10 B ratios can be used to characterize wines from different geographical origins. Average 11 B/ 10 B ratios in red wines from South Africa (Stellenbosch), France (Bergerac), and Italy (Valpolicella) were found to differ by between 0.5 and 1.5%. (orig.)

  5. Comparison of GC-ICP-MS and HPLC-ICP-MS for species-specific isotope dilution analysis of tributyltin in sediment after accelerated solvent extraction

    International Nuclear Information System (INIS)

    Wahlen, Raimund; Wolff-Briche, Celine

    2003-01-01

    This study describes a direct comparison of GC and HPLC hyphenated to ICP-MS determination of tributyltin (TBT) in sediment by species-specific isotope dilution analysis (SS-IDMS). The certified reference sediment PACS-2 (NRC, Canada) and a candidate reference sediment (P-18/HIPA-1) were extracted using an accelerated solvent extraction (ASE) procedure. For comparison of GC and LC methods an older bottle of PACS-2 was used, whilst a fresh bottle was taken for demonstration of the accuracy of the methods. The data obtained show good agreement between both methods for both the PACS-2 sediment (LC-ICP-IDMS 828±87 ng g -1 TBT as Sn, GC-ICP-IDMS 848±39 ng g -1 TBT as Sn) and the P-18/ HIPA-1 sediment (LC-ICP-IDMS 78.0±9.7 ng g -1 TBT as Sn, GC-ICP-IDMS 79.2±3.8 ng g -1 TBT as Sn). The analysis by GC-ICP-IDMS offers a greater signal-to-noise ratio and hence a superior detection limit of 0.03 pg TBT as Sn, in the sediment extracts compared to HPLC-ICP-IDMS (3 pg TBT as Sn). A comparison of the uncertainties associated with both methods indicates superior precision of the GC approach. This is related to the better reproducibility of the peak integration, which affects the isotope ratio measurements used for IDMS. The accuracy of the ASE method combined with HPLC-ICP-IDMS was demonstrated during the international interlaboratory comparison P-18 organised by the Comite Consultatif pour la Quantite de Matiere (CCQM). The results obtained by GC-ICP-IDMS for a newly opened bottle of PACS-2 were 1087±77 ng g -1 Sn for DBT and 876±51 ng g -1 Sn for TBT (expanded uncertainties with a coverage factor of 2), which are in good agreement with the certified values of 1090±150 ng g -1 Sn and 980±130 ng g -1 Sn, respectively. (orig.)

  6. Determination of trace amounts of rare-earth elements in highly pure neodymium oxide by sector field inductively coupled plasma mass spectrometry (ICP-SFMS) and high-performance liquid chromatography (HPLC) techniques

    Science.gov (United States)

    Pedreira, W. R.; Sarkis, J. E. S.; da Silva Queiroz, C. A.; Rodrigues, C.; Tomiyoshi, I. A.; Abrão, A.

    2003-02-01

    Recently rare-earth elements (REE) have received much attention in fields of geochemistry and industry. Rapid and accurate determinations of them are increasingly required as industrial demands expand. Sector field inductively coupled plasma mass spectrometry (ICP-SFMS) with high-performance liquid chromatography (HPLC) has been applied to the determination of REE. HR ICP-MS was used as an element-selective detector for HPLC in highly pure materials. The separation of REE with HPLC helped to avoid erroneous analytical results due to spectral interferences. Sixteen elements (Sc, Y and 14 lanthanides) were determined selectively with the HPLC/ICP-SFMS system using a concentration gradient methods. The detection limits with the HPLC/ICP-SFMS system were about 0.5-10 pg mL-1. The percentage recovery ranged from 90% to 100% for different REE. The %RSD of the methods varying between 2.5% and 4.5% for a set of five (n=5) replicates was found for the IPEN's material and for the certificate reference sample. Determination of trace REEs in two highly pure neodymium oxides samples (IPEN and Johnson Matthey Company) were performed. In short, the IPEN's materials which are highly pure (>99.9%) were successfully analyzed without spectral interferences.

  7. Determination of trace amounts of rare-earth elements in highly pure neodymium oxide by sector field inductively coupled plasma mass spectrometry (ICP-SFMS) and high-performance liquid chromatography (HPLC) techniques

    International Nuclear Information System (INIS)

    Pedreira, W.R.; Sarkis, J.E.S.; Silva Queiroz, C.A. da; Rodrigues, C.; Tomiyoshi, I.A.; Abrao, A.

    2003-01-01

    Recently rare-earth elements (REE) have received much attention in fields of geochemistry and industry. Rapid and accurate determinations of them are increasingly required as industrial demands expand. Sector field inductively coupled plasma mass spectrometry (ICP-SFMS) with high-performance liquid chromatography (HPLC) has been applied to the determination of REE. HR ICP-MS was used as an element-selective detector for HPLC in highly pure materials. The separation of REE with HPLC helped to avoid erroneous analytical results due to spectral interferences. Sixteen elements (Sc, Y and 14 lanthanides) were determined selectively with the HPLC/ICP-SFMS system using a concentration gradient methods. The detection limits with the HPLC/ICP-SFMS system were about 0.5-10 pg mL -1 . The percentage recovery ranged from 90% to 100% for different REE. The %RSD of the methods varying between 2.5% and 4.5% for a set of five (n=5) replicates was found for the IPEN's material and for the certificate reference sample. Determination of trace REEs in two highly pure neodymium oxides samples (IPEN and Johnson Matthey Company) were performed. In short, the IPEN's materials which are highly pure (>99.9%) were successfully analyzed without spectral interferences

  8. Genome-Wide Identification and Expression Analysis of the UGlcAE Gene Family in Tomato

    Directory of Open Access Journals (Sweden)

    Xing Ding

    2018-05-01

    Full Text Available The UGlcAE has the capability of interconverting UDP-d-galacturonic acid and UDP-d-glucuronic acid, and UDP-d-galacturonic acid is an activated precursor for the synthesis of pectins in plants. In this study, we identified nine UGlcAE protein-encoding genes in tomato. The nine UGlcAE genes that were distributed on eight chromosomes in tomato, and the corresponding proteins contained one or two trans-membrane domains. The phylogenetic analysis showed that SlUGlcAE genes could be divided into seven groups, designated UGlcAE1 to UGlcAE6, of which the UGlcAE2 were classified into two groups. Expression profile analysis revealed that the SlUGlcAE genes display diverse expression patterns in various tomato tissues. Selective pressure analysis indicated that all of the amino acid sites of SlUGlcAE proteins are undergoing purifying selection. Fifteen stress-, hormone-, and development-related elements were identified in the upstream regions (0.5 kb of these SlUGlcAE genes. Furthermore, we investigated the expression patterns of SlUGlcAE genes in response to three hormones (indole-3-acetic acid (IAA, gibberellin (GA, and salicylic acid (SA. We detected firmness, pectin contents, and expression levels of UGlcAE family genes during the development of tomato fruit. Here, we systematically summarize the general characteristics of the SlUGlcAE genes in tomato, which could provide a basis for further function studies of tomato UGlcAE genes.

  9. Key features of MIR.1200 (AES-2006) design and current stage of Leningrad NPP-2 construction

    International Nuclear Information System (INIS)

    Ivkov, Igor

    2010-01-01

    MIR.1200/AES-2006 is an abbreviated name of the evolving NPP design developed on the basis of the VVER-1000 Russian design with gross operation life of 480 reactor-years. This design is being implemented in four Units of Leningrad NPP-2 (LNPP-2. The AES-91/99 was used as reference during development of the AES-2006 design for LNPP-2; this design was implemented in two Units of Tianwan NPP (China). The main technical features of the MIR.1200/AES-2006 design include a double containment, four trains of active safety systems (4x100%, 4x50%), and special engineering measures for BDBA management (core catcher, H2 PARs, PHRS) based mainly on passive principles. The containment is described in detail, the main features in comparison with the reference NPP are outlined, the design layout principles are highlighted, the safety system structure and parameters are described. Attention is paid to the BDBA management system, hydrogen removal system, core catcher, and PHRS-SG and C-PHRS. (P.A.)

  10. IUE observations of W UMa systems AE Phoenicis and TY Mensae

    International Nuclear Information System (INIS)

    Rucinski, S.M.

    1984-01-01

    SWP spectra of AE Phe and TY Men are presented and discussed. The spectrum of AE Phe is typical in showing strong emission lines which originate in the chromosphere and transition region. On the basis of the strenght of the He II emission line we predict that AE Phe should be a moderately strong X-ray source. The spectrum of TY Men is too weakly exposed for a full discussion. It is pointed out that this star is one of the most important for understanding the activity in W UMa systems. 18 refs., 3 figs., 1 tab. (author)

  11. Lead isotope measurements on aerosol samples with ICP-MS

    International Nuclear Information System (INIS)

    Widmer, C.R.; Kraehenbuehl, U.; Kramers, J.; Tobler, L.

    2000-01-01

    Size fractionated aerosols were collected with low pressure Berner impactors on a radio/TV tower 110 m above ground on a hill 10 km east of Bern at a total elevation of 1060 m asl. Two different wind sectors were chosen with the goal of assessing any differences in lead concentration and the 3 radiogenic lead isotopes (206,207,208) for east and west wind, respectively. A leaching technique was used to extract the lead quantitatively from the surface of the impaction foils. This method has been proven to be better suited for airborne particles than complete microwave digestion because it is less time consuming and contamination risk is smaller. Blank considerations played a major role in choosing all the chemicals, tubes, beakers and selecting the analytical method. Lead concentrations were determined with GF-AAS and lead isotopes with two different ICP-MS systems, one being a multicollector system. Precision of the simultaneous multicollector system was found to be at least a factor of 3 better than that of the sequentially operating ICP-MS. The small variations in isotope ratios from the two wind sectors can be distinctly seen with this enhanced precision. The observed relative difference in isotope ratios between east- and westwind was ∝0.6% for 207 Pb/ 206 Pb and ∝0.5% for 208 Pb/ 206 Pb. (orig.)

  12. Genome-Wide Identification and Expression Analysis of the UGlcAE Gene Family in Tomato

    OpenAIRE

    Xing Ding; Jinhua Li; Yu Pan; Yue Zhang; Lei Ni; Yaling Wang; Xingguo Zhang

    2018-01-01

    The UGlcAE has the capability of interconverting UDP-d-galacturonic acid and UDP-d-glucuronic acid, and UDP-d-galacturonic acid is an activated precursor for the synthesis of pectins in plants. In this study, we identified nine UGlcAE protein-encoding genes in tomato. The nine UGlcAE genes that were distributed on eight chromosomes in tomato, and the corresponding proteins contained one or two trans-membrane domains. The phylogenetic analysis showed that SlUGlcAE genes could be divided into s...

  13. Determination of Long-lived Radionuclides in the Environment using ICP-MS and AMS

    DEFF Research Database (Denmark)

    Hou, Xiaolin

    2011-01-01

    ICP-MS and AMS have been widely used for the measurement of radionuclides, especially long-lived radionculides. The new progress, major advantages of these two techniques and their major applications for measurement of important radionculides are summarized.......ICP-MS and AMS have been widely used for the measurement of radionuclides, especially long-lived radionculides. The new progress, major advantages of these two techniques and their major applications for measurement of important radionculides are summarized....

  14. ICP-MS and elemental tags for the life sciences

    Energy Technology Data Exchange (ETDEWEB)

    Giesen, Charlotte

    2012-08-07

    Inductively coupled plasma mass spectrometry (ICP-MS) has been applied for the analysis of biomolecules due to its high sensitivity, wide linear dynamic range, and multielement capabilities. However, outside the elemental MS community the potential of this technique, e.g. for life sciences applications, is not yet fully exploited. Thus, the development of ICP-MS-based (immuno) assays for a wide range of medical (cancer diagnostics, cisplatin toxicity studies), biochemical (DNA microarray, single cell analysis), and environmental (analysis of comestible goods) applications was accomplished by utilization of chemical labels. Laser ablation (LA)-ICP-MS was employed for the direct analysis of solid samples like microarrays and thin tissue sections. An immunoassay was developed for ochratoxin A (OTA) determination in wine, and ICP-MS detection was compared to conventional photometry by gold nanoparticle tagging and horseradish peroxidase, respectively. Detection limits of the assay were optimized to 0.003 {mu}g L{sup -1}, and the quantification range was 0.01-1 {mu}g L{sup -1} for both methods. For LA-ICP-MS-based DNA microarray detection, gold nanoparticle tags were specifically introduced via a streptavidin-biotin linkage. In immunohistochemistry (IHC), up to 20 tumor markers are routinely evaluated for one patient and thus, a common analysis results in a series of time consuming staining procedures. Hence, LA-ICP-MS was elaborated as a detection tool for a novel, multiplexed IHC analysis of tissue sections. Different lanthanides were employed for the simultaneous detection of up to three tumor markers (Her 2, CK 7, and MUC 1) in a breast cancer tissue. Additionally, iodine was employed as a labeling reagent, and a new LA-ICP-MS method for single cell and cell nucleus imaging was developed at 4 {mu}m laser spot size. Iodine was also applied as a new internal standard for tissue samples. Moreover, Pt-protein complexes separated by an optimized 1D and 2D gel

  15. Rapid Analysis of U isotopic ratios in Food Stuff samples using Fusion and ICP-MS measurement: For radiation monitoring program in the vicinity of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jong Myoung; Park, Ji Young; Jung, Yoon Hee; Kim, Hyun Cheol; Kim, Won Young; Chung, Gun Ho; Kang, Mun Ja [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this study, a rapid digestion and separation method for U isotopes was developed in food stuff matrix such as cabbage and rice. As an attempt to reduce social costs and apprehension arising from the radioactivity in food, an accurate and rapid assessment of radioactivity is highly desirable. Hence, it is very important to develop a series of evaluation of rapid procedures for efficient radioactivity management in food. Contrary to the α-spectrometry method, a measurement technique using ICP-MS with an advanced sample introduction and mass counting system allows radioactivity in many samples to be measured with a short time period with a high degree of accuracy and precision. In order to satisfy the method detectable activity (MDA) for the regulation of radioactivity monitoring program the analysis of U isotopes always require the extremely large sample amount. These procedures make usually the food stuff sample to carbonize during dry ashing process. The ashed residues have been especially complicated into a liquid phase because of their carbonization. This process are very time consuming and not fully recovered target isotopes.

  16. Bioimaging of isosteric osmium and ruthenium anticancer agents by LA-ICP-MS.

    Science.gov (United States)

    Klose, Matthias H M; Theiner, Sarah; Kornauth, Christoph; Meier-Menches, Samuel M; Heffeter, Petra; Berger, Walter; Koellensperger, Gunda; Keppler, Bernhard K

    2018-03-01

    Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to study the spatial distribution of two metallodrugs with anticancer activities in vivo, namely the organoruthenium plecstatin-1 (1) and its isosteric osmium analogue (2), in liver, kidneys, muscles and tumours of treated mice bearing a CT-26 tumour after single-dose i.p. administration. To the best of our knowledge, this is the first time that the spatial distribution of an osmium drug candidate has been investigated using LA-ICP-MS in tissues. Independent measurements of the average ruthenium and osmium concentration via microwave digestion and ICP-MS in organs and tumours were in good agreement with the LA-ICP-MS results. Matrix-matched standards (MMS) ranging from 1 to 30 μg g -1 were prepared to quantify the spatial distributions of the metals and the average metal content of the MMS samples was additionally quantified by ICP-MS after microwave digestion. The recoveries for osmium and ruthenium in the MMS were 105% and 101% on average, respectively, validating the sample preparation procedure of the MMS. Preparation of MMS was carried out under an argon atmosphere to prevent oxidation of osmium-species to the volatile OsO 4 . The highest metal concentrations were found in the liver, followed by kidney, lung and tumour tissues, while muscles displayed only very low quantities of the respective metal. Both metallodrugs accumulated in the cortex of the kidneys more strongly compared to the medulla. Interestingly, osmium from 2 was largely located at the periphery and tissue edges, whereas ruthenium from 1 was observed to penetrate deeper into the organs and tumours.

  17. Development of analytical methods for the determination of trace elements in sediment with Neutron ActivAtion method (NAA) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Nam, Sang Ho; Kim, Jae Jin; Chung, Yong Sam; Kim, Sun Ha

    2005-01-01

    The analytical methods for the determination of major elements (Al, Ca, K, Fe, Mg) in sediment have been investigated with ICP-MS. The analytical results of major elements with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA. NAA were a little superior to ICP-MS for the determination of major elements in sediment, and NAA is a non-destructive analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) in sediment have been also studied with ICP-MS. The analytical results by standard calibration with ICP-MS were not accurate due to matrix interferences. Thus, internal standard method was applied, then the analytical results for minor element with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments

  18. Examination Of Sulfur Measurements In DWPF Sludge Slurry And SRAT Product Materials

    International Nuclear Information System (INIS)

    Bannochie, C. J.; Wiedenman, B. J.

    2012-01-01

    Savannah River National Laboratory (SRNL) was asked to re-sample the received SB7b WAPS material for wt. % solids, perform an aqua regia digestion and analyze the digested material by inductively coupled plasma - atomic emission spectroscopy (ICP-AES), as well as re-examine the supernate by ICP-AES. The new analyses were requested in order to provide confidence that the initial analytical subsample was representative of the Tank 40 sample received and to replicate the S results obtained on the initial subsample collected. The ICP-AES analyses for S were examined with both axial and radial detection of the sulfur ICP-AES spectroscopic emission lines to ascertain if there was any significant difference in the reported results. The outcome of this second subsample of the Tank 40 WAPS material is the first subject of this report. After examination of the data from the new subsample of the SB7b WAPS material, a team of DWPF and SRNL staff looked for ways to address the question of whether there was in fact insoluble S that was not being accounted for by ion chromatography (IC) analysis. The question of how much S is reaching the melter was thought best addressed by examining a DWPF Slurry Mix Evaporator (SME) Product sample, but the significant dilution of sludge material, containing the S species in question, that results from frit addition was believed to add additional uncertainty to the S analysis of SME Product material. At the time of these discussions it was believed that all S present in a Sludge Receipt and Adjustment Tank (SRAT) Receipt sample would be converted to sulfate during the course of the SRAT cycle. A SRAT Product sample would not have the S dilution effect resulting from frit addition, and hence, it was decided that a DWPF SRAT Product sample would be obtained and submitted to SRNL for digestion and sample preparation followed by a round-robin analysis of the prepared samples by the DWPF Laboratory, F/H Laboratories, and SRNL for S and sulfate. The

  19. Some practical applications of an ICP-MS instrument

    International Nuclear Information System (INIS)

    Meddings, B.; Ng, R.

    1987-01-01

    An early model commercial ICP-MS instrument (PlasmaQuad from VG Isotopes Limited) was acquired more than two years ago. As a typical analytical laboratory in the metallurgical field, the application of the ICP-MS technique to real sample analysis is the authors prime concern. The process of introducing this state-of-the-art instrument into routine analysis will be described. The modifications and limitations necessary to achieve acceptable precision under normal working conditions will be outlined. In most cases, practical problems can be circumvented with some sacrifice in analytical performance in the area of detection limits and dynamic range. In this presentation, specific applications of the ICP-MS technique in the authors laboratory will be discussed. These include trace analysis on high purity metals such as copper, aluminum, cobalt, nickel etc., on refinery feed samples such as nickel sulfate, mixed cobalt and nickel sulfide, cobalt cathode, samarium oxide etc., on alloys such as cobalt-samarium magnetic materials, nickel or cobalt based alloys used in turbine blades etc. Other applications such as the determination of uranium in phosphate rock, trace analysis on fertilizers, water samples and high purity acids will also be mentioned. The solutions to the practical problems encountered in these applications will be discussed. The analytical power of the ICP-MS technique for real sample analysis will be assessed

  20. Quality control of Al alloy by ICP-MS

    International Nuclear Information System (INIS)

    Zahran, N.F.; Amr, M.A.; Helal, A.I.; Waly, S.A.; Afifi, Y.K.

    2000-01-01

    Laser ablation sample introduction system in combination with an inductive coupled plasma mass spectrometer (ICP-MS) is used for the investigation of elemental distribution of Al alloy. The samples are ablated by an ultraviolet laser beam at 266 nm with an energy of 4mJ/shot at a repetition rate of 20 Hz. Samples are digested using HNO 3 in a microwave system and analyzed in a solution form by ICP-MS. The quantification of the analytical results is carried out using multielement solution. Quantitative data from the solution samples are used as a standard data for the laser ablation technique. The effect of Aluminum as a matrix is studied. High-resolution mass spectrometer is used to identify the Aluminum polyatomic ions in the ICP-ion source

  1. Analysis of twenty five impurities in uranium matrix by ICP-MS with iron measurement optimized by using reaction collision cell, cold plasma or medium resolution

    International Nuclear Information System (INIS)

    Quemet, Alexandre; Brennetot, Rene; Chevalier, Emilie; Prian, Edwina; Laridon, Anne-Laure; Fichet, Pascal; Goutelard, Florence; Mariet, Clarisse; Laszak, Ivan

    2012-01-01

    An analytical procedure was developed to determine the concentration of 25 impurities (Li, Be, Ti, V. Cr, Mn, Fe, Co, Ni, Cu, Zn, Zr, Mo, Ag, Cd, In, Sm, Eu, Gd, Dy, W, Pb, Bi and Th) in a uranium matrix using the quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS). The dissolution of U 3 O 8 powder was made with a mixture of hydrochloric acid and nitric acid. Then, a selective separation of uranium using the UTEVA column was used before measurement by Q-ICP-MS. The procedure developed was verified using the Certified Reference Material 'Morille'. The analytical results agree well except for 5 elements where values are underestimated (Li, Be, In, Pb and Bi). Among the list of impurities, iron was particularly investigated because it is well known that this element possesses a polyatomic interference that increases the detection limit. A comparison between iron detection limits obtained with different methods was performed. Iron polyatomic interference was at least reduced, or at best entirely resolved in some cases, by using the cold plasma or the collision/reaction cell with several gases (He, NH 3 and CH 4 ). High-resolution ICP-MS was used to compare the results obtained. A detection limit as low as 8 ng L -1 was achieved. (authors)

  2. AES in deficit on Georgian trade

    International Nuclear Information System (INIS)

    TREND

    2003-01-01

    According to Vedomosti journal Russian state energy company RAO JES Rossii paid for Georgian assets acquisition to American company AES only 23 million USD, what is less than a tenth of sum which AES had originally paid for it. Thus total transaction value including debts reached 80 millions USD. But internal documents of American AES confirm that Americans paid 260 millions USD for Georgian assets and they took besides over 60 millions USD of obligations. Russians bought Georgian AES assets through Finnish filial Nordic Oy. Thus they obtained 75 per cent share in Telasi company which operates distributive network in Tbilisi, two blocks of plant in Tbilisi and half share in AES-Transenergy company which exports electric energy from Georgia to Turkey. RAO JES besides got managerial laws on Hramesi company which owns two water plants. Russian company controls one fifth of production and 35 per cent of electric energy sale in Georgia by these assets

  3. Fundamental studies of interferences in ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Rowley, L.K

    2000-11-01

    Methods of temperature measurement by mass spectrometry have been critically reviewed. It was concluded that the most appropriate method depended critically on the availability of fundamental data, hence a database of fundamental spectroscopic constants, for diatomic ions which cause interferences in ICP-MS, was compiled. The equilibration temperature, calculated using the different methods and using various diatomic ions as the thermometric probes, was between c.a. 400 - 10,000 K in the central channel, and between c.a. 600 - 16,000 K when the plasma was moved 1.8 mm off-centre. The wide range in temperature reflected the range of temperature measurement methods and uncertainty in the fundamental data. Optical studies using a fibre optic connected to a monochromator were performed in order to investigate the presence of interferences both in the plasma and the interface region of the ICP-MS, and the influence of a shielded torch on these interferences. It was possible to determine the presence of some species in the plasma, such as the strongly bound metal oxides, however, no species other than OH were detected in the interface region of the ICP-MS. The OH rotational temperature within the interface region of the ICP-MS was calculated to be between 2,000 - 4,000 K. The effect of sampling depth, operating power, radial position and solvent loading, with and without the shielded torch, on the dissociation temperature of a variety of polyatomic interferences was investigated. These calculated temperatures were then used to elucidate the site of formation for different polyatomic interferences. Results confirmed that strongly bound ions such as MO{sup +} were formed in the plasma, whereas weakly bound ions such as ArO{sup +} were formed in the interface region due to gross deviation of the calculated temperatures from those expected for a system in thermal equilibrium. (author)

  4. Registration of TLS and MLS Point Cloud Combining Genetic Algorithm with ICP

    Directory of Open Access Journals (Sweden)

    YAN Li

    2018-04-01

    Full Text Available Large scene point cloud can be quickly acquired by mobile laser scanning (MLS technology,which needs to be supplemented by terrestrial laser scanning (TLS point cloud because of limited field of view and occlusion.MLS and TLS point cloud are located in geodetic coordinate system and local coordinate system respectively.This paper proposes an automatic registration method combined genetic algorithm (GA and iterative closed point ICP to achieve a uniform coordinate reference frame.The local optimizer is utilized in ICP.The efficiency of ICP is higher than that of GA registration,but it depends on a initial solution.GA is a global optimizer,but it's inefficient.The combining strategy is that ICP is enabled to complete the registration when the GA tends to local search.The rough position measured by a built-in GPS of a terrestrial laser scanner is used in the GA registration to limit its optimizing search space.To improve the GA registration accuracy,a maximum registration model called normalized sum of matching scores (NSMS is presented.The results for measured data show that the NSMS model is effective,the root mean square error (RMSE of GA registration is 1~5 cm and the registration efficiency can be improved by about 50% combining GA with ICP.

  5. ICP-MS with hexapole collision cell for isotope ratio measurements of Ca, Fe, and Se.

    Science.gov (United States)

    Boulyga, S F; Becker, J S

    2001-07-01

    To avoid mass interferences on analyte ions caused by argon ions and argon molecular ions via reactions with collision gases, an rf hexapole filled with helium and hydrogen has been used in inductively coupled plasma mass spectrometry (ICP-MS), and its performance has been studied. Up to tenfold improvement in sensitivity was observed for heavy elements (m > 100 u), because of better ion transmission through the hexapole ion guide. A reduction of argon ions Ar+ and the molecular ions of argon ArX+ (X = O, Ar) by up to three orders of magnitude was achieved in a hexapole collision cell of an ICP-MS ("Platform ICP", Micromass, Manchester, UK) as a result of gas-phase reactions with hydrogen when the hexapole bias (HB) was set to 0 V; at an HB of 1.6 V argon, and argon-based ions of masses 40 u, 56 u, and 80 u, were reduced by approximately four, two, and five orders of magnitude, respectively. The signal-to-noise ratio 80Se/ 40Ar2+ was improved by more than five orders of magnitude under optimized experimental conditions. Dependence of mass discrimination on collision-cell properties was studied in the mass range 10 u (boron) to 238 u (uranium). Isotopic analysis of the elements affected by mass-spectrometric interference, Ca, Fe, and Se, was performed using a Meinhard nebulizer and an ultrasonic nebulizer (USN). The measured isotope ratios were comparable with tabulated values from IUPAC. Precision of 0.26%, 0.19%, and 0.12%, respectively, and accuracy of 0.13% 0.25%, and 0.92%, respectively, was achieved for isotope ratios 44Ca/ 40Ca and 56Fe/57Fe in 10 microg L(-1) solution nebulized by means of a USN and for 78Se/80Se in 100 microg L(-1) solution nebulized by means of a Meinhard nebulizer.

  6. Investigation of ceramic materials using ICP-AES with external electrothermal vaporization

    International Nuclear Information System (INIS)

    Reisch, M.; Gartz, R.; Mazurkiewicz, M.; Nickel, H.

    1989-01-01

    The evaporation and excitation processes for several trace elements in ceramic powders are studied. The advantages of an electrothermal vaporization are the easier preparation, no dilution and a shorter experiment duration. The investigated ceramic powders consist of synthetic mixtures including the systems Al 2 O 3 -SiO 2 and Al 2 O 3 -MgO. The trace elements are bound as oxides. The evaporation is monitored by 59 Fe and 115 Cd. Since the evaporation rates are measured in addition to line intensities, the influence of various parameters on evaporation as well as on excitation processes can be individually examined. The influence of matrix composition is determined. It is found that melting and sintering processes of the matrix are of great importance for the evaporation of trace elements. Thus the best results are obtained when trace elements evaporate below the melting temperature of the matrix. Therefore the addition of thermochemical substances is necessary for several elements of low volatility. In the case of highly volatile elements, for example Cd, additives seemed to have only a small influence on the volatilization rate. Accordingly, only the excitation is affected. For example, the evaporation rate of Cd is constant through the whole Al 2 O 3 -MgO system. The measured line intensity of Cd is also constant within a large range of MgO content. The evaporation rate and line intensity of Fe decrease linearly with MgO concentration. (author)

  7. Determination of 129I/127I isotope ratios in liquid solutions and environmental soil samples by ICP-MS with hexapole collision cell

    OpenAIRE

    Izmer, A. V.; Boulyga, S. F.; Becker, J. S.

    2003-01-01

    The determination of I-129 in environmental samples at ultratrace levels is very difficult by ICP-MS due to a high noise caused by Xe impurities in argon plasma gas (interference of Xe-129(+)), possible (IH2+)-I-127 interference and an insufficient abundance ratio sensitivity of the ICP mass spectrometer for I-129/I-127 isotope ratio measurement. A sensitive, powerful and fast analytical technique for iodine isotope ratio measurements in aqueous solutions and contaminated soil samples directl...

  8. Characterization of Elements Regulating the Nuclear-to-Cytoplasmic Translocation of ICP0 in Late Herpes Simplex Virus 1 Infection.

    Science.gov (United States)

    Samrat, Subodh Kumar; Ha, Binh L; Zheng, Yi; Gu, Haidong

    2018-01-15

    Infected cell protein 0 (ICP0) of herpes simplex virus 1 (HSV-1) is an immediate early protein containing a RING-type E3 ubiquitin ligase. It targets several host factors for proteasomal degradation and subsequently activates viral expression. ICP0 has a nuclear localization sequence and functions in the nucleus early during infection. However, later in infection, ICP0 is found solely in the cytoplasm. The molecular mechanism and biological function of the ICP0 nuclear-to-cytoplasmic translocation are not well understood. In this study, we sought to characterize elements important for this translocation. We found that (i) in human embryonic lung fibroblast (HEL) cells, ICP0 C-terminal residues 741 to 775 were necessary but not sufficient for the nuclear-to-cytoplasmic translocation; (ii) the loss of ICP0 E3 ubiquitin ligase activity, which led to defective viral replication in nonpermissive cells, also caused mutant ICP0 to be retained in the nucleus of HEL cells; (iii) in permissive U2OS cells, however, ICP0 lacking E3 ligase activity was translocated to the cytoplasm at a pace faster than that of wild-type ICP0, suggesting that nuclear retention of ICP0 occurs in an ICP0 E3 ligase-dependent manner; and (iv) the ICP0 C terminus and late viral proteins cooperate in order to overcome nuclear retention and stimulate ICP0 cytoplasmic translocation. Taken together, less ICP0 nuclear retention may contribute to the permissiveness of U2OS cells to HSV-1 in the absence of functional ICP0. IMPORTANCE A distinct characteristic for eukaryotes is the compartmentalization of cell metabolic pathways, which allows greater efficiency and specificity of cellular functions. ICP0 of HSV-1 is a multifunctional viral protein that travels through different compartments as infection progresses. Its main regulatory functions are carried out in the nucleus, but it is translocated to the cytoplasm late during HSV-1 infection. To understand the biological significance of cytoplasmic ICP0 in

  9. Evaluation of the combined measurement uncertainty in isotope dilution by MC-ICP-MS

    International Nuclear Information System (INIS)

    Fortunato, G.; Wunderli, S.

    2003-01-01

    The combination of metrological weighing, the measurement of isotope amount ratios by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) and the use of high-purity reference materials are the cornerstones to achieve improved results for the amount content of lead in wine by the reversed isotope dilution technique. Isotope dilution mass spectrometry (IDMS) and reversed IDMS have the potential to be a so-called primary method, with which close comparability and well-stated combined measurement uncertainties can be obtained. This work describes the detailed uncertainty budget determination using the ISO-GUM approach. The traces of lead in wine were separated from the matrix by ion exchange chromatography after HNO 3 /H 2 O 2 microwave digestion. The thallium isotope amount ratio (n( 205 Tl)/n( 203 Tl)) was used to correct for mass discrimination using an exponential model approach. The corrected lead isotope amount ratio n( 206 Pb)/n( 208 Pb) for the isotopic standard SRM 981 measured in our laboratory was compared with ratio values considered to be the least uncertain. The result has been compared in a so-called pilot study ''lead in wine'' organised by the CCQM (Comite Consultatif pour la Quantite de Matiere, BIPM, Paris; the highest measurement authority for analytical chemical measurements). The result for the lead amount content k(Pb) and the corresponding expanded uncertainty U given by our laboratory was:k(Pb)=1.329 x 10-10mol g-1 (amount content of lead in wine)U[k(Pb)]=1.0 x 10-12mol g-1 (expanded uncertainty U=k x uc, k=2) The uncertainty of the main influence parameter of the combined measurement uncertainty was determined to be the isotope amount ratio R 206,B of the blend between the enriched spike and the sample. (orig.)

  10. HSV-1 ICP0: An E3 Ubiquitin Ligase That Counteracts Host Intrinsic and Innate Immunity

    Directory of Open Access Journals (Sweden)

    Mirna Perusina Lanfranca

    2014-05-01

    Full Text Available The herpes simplex virus type 1 (HSV-1 encoded E3 ubiquitin ligase, infected cell protein 0 (ICP0, is required for efficient lytic viral replication and regulates the switch between the lytic and latent states of HSV-1. As an E3 ubiquitin ligase, ICP0 directs the proteasomal degradation of several cellular targets, allowing the virus to counteract different cellular intrinsic and innate immune responses. In this review, we will focus on how ICP0’s E3 ubiquitin ligase activity inactivates the host intrinsic defenses, such as nuclear domain 10 (ND10, SUMO, and the DNA damage response to HSV-1 infection. In addition, we will examine ICP0’s capacity to impair the activation of interferon (innate regulatory mediators that include IFI16 (IFN γ-inducible protein 16, MyD88 (myeloid differentiation factor 88, and Mal (MyD88 adaptor-like protein. We will also consider how ICP0 allows HSV-1 to evade activation of the NF-κB (nuclear factor kappa B inflammatory signaling pathway. Finally, ICP0’s paradoxical relationship with USP7 (ubiquitin specific protease 7 and its roles in intrinsic and innate immune responses to HSV-1 infection will be discussed.

  11. 15 CFR 758.2 - Automated Export System (AES).

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Automated Export System (AES). 758.2... CLEARANCE REQUIREMENTS § 758.2 Automated Export System (AES). The Census Bureau's Foreign Trade Statistics...) electronically using the Automated Export System (AES). In order to use AES, you must apply directly to the...

  12. Effect of ECAP processing on corrosion resistance of AE21 and AE42 magnesium alloys

    Science.gov (United States)

    Minárik, P.; Král, R.; Janeček, M.

    2013-09-01

    Corrosion properties of AE21 and AE42 magnesium alloys were investigated in the extruded state and after subsequent 8 passes of Equal Channel Angular Pressing (ECAP) via route Bc, by Electrochemical Impedance Spectroscopy (EIS) in 0.1 M NaCl solution. The resulting microstructure was observed by the Transmission Electron Microscope (TEM) and the Scanning Electron Microscope (SEM). Corrosion layer created after 7 days of immersion was observed by (SEM) in order to explain different evolution of the corrosion resistance after ECAP processing in both alloys. It was found that Al-rich Al11RE3 dispersed particles (present in both alloys) strongly influence the corrosion process and enhance the corrosion resistance. Ultra-fine grained structure was found to reduce the corrosion resistance in AE21. On the other hand, the microstructure of AE42 after ECAP and particularly the better distribution of the alloying elements in the matrix enhance the corrosion resistance when compared to the extruded material.

  13. Effect of ECAP processing on corrosion resistance of AE21 and AE42 magnesium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Minárik, P., E-mail: peter.minarik@mff.cuni.cz [Charles University, Department of Physics of Materials, Prague (Czech Republic); Král, R.; Janeček, M. [Charles University, Department of Physics of Materials, Prague (Czech Republic)

    2013-09-15

    Corrosion properties of AE21 and AE42 magnesium alloys were investigated in the extruded state and after subsequent 8 passes of Equal Channel Angular Pressing (ECAP) via route Bc, by Electrochemical Impedance Spectroscopy (EIS) in 0.1 M NaCl solution. The resulting microstructure was observed by the Transmission Electron Microscope (TEM) and the Scanning Electron Microscope (SEM). Corrosion layer created after 7 days of immersion was observed by (SEM) in order to explain different evolution of the corrosion resistance after ECAP processing in both alloys. It was found that Al-rich Al11RE3 dispersed particles (present in both alloys) strongly influence the corrosion process and enhance the corrosion resistance. Ultra-fine grained structure was found to reduce the corrosion resistance in AE21. On the other hand, the microstructure of AE42 after ECAP and particularly the better distribution of the alloying elements in the matrix enhance the corrosion resistance when compared to the extruded material.

  14. Effect of ECAP processing on corrosion resistance of AE21 and AE42 magnesium alloys

    International Nuclear Information System (INIS)

    Minárik, P.; Král, R.; Janeček, M.

    2013-01-01

    Corrosion properties of AE21 and AE42 magnesium alloys were investigated in the extruded state and after subsequent 8 passes of Equal Channel Angular Pressing (ECAP) via route Bc, by Electrochemical Impedance Spectroscopy (EIS) in 0.1 M NaCl solution. The resulting microstructure was observed by the Transmission Electron Microscope (TEM) and the Scanning Electron Microscope (SEM). Corrosion layer created after 7 days of immersion was observed by (SEM) in order to explain different evolution of the corrosion resistance after ECAP processing in both alloys. It was found that Al-rich Al11RE3 dispersed particles (present in both alloys) strongly influence the corrosion process and enhance the corrosion resistance. Ultra-fine grained structure was found to reduce the corrosion resistance in AE21. On the other hand, the microstructure of AE42 after ECAP and particularly the better distribution of the alloying elements in the matrix enhance the corrosion resistance when compared to the extruded material.

  15. Structural, elastic, electronic, optical and thermoelectric properties of the Zintl-phase Ae3AlAs3 (Ae = Sr, Ba)

    Science.gov (United States)

    Benahmed, A.; Bouhemadou, A.; Alqarni, B.; Guechi, N.; Al-Douri, Y.; Khenata, R.; Bin-Omran, S.

    2018-05-01

    First-principles calculations were performed to investigate the structural, elastic, electronic, optical and thermoelectric properties of the Zintl-phase Ae3AlAs3 (Ae = Sr, Ba) using two complementary approaches based on density functional theory. The pseudopotential plane-wave method was used to explore the structural and elastic properties whereas the full-potential linearised augmented plane wave approach was used to study the structural, electronic, optical and thermoelectric properties. The calculated structural parameters are in good consistency with the corresponding measured ones. The single-crystal and polycrystalline elastic constants and related properties were examined in details. The electronic properties, including energy band dispersions, density of states and charge-carrier effective masses, were computed using Tran-Blaha modified Becke-Johnson functional for the exchange-correlation potential. It is found that both studied compounds are direct band gap semiconductors. Frequency-dependence of the linear optical functions were predicted for a wide photon energy range up to 15 eV. Charge carrier concentration and temperature dependences of the basic parameters of the thermoelectric properties were explored using the semi-classical Boltzmann transport model. Our calculations unveil that the studied compounds are characterised by a high thermopower for both carriers, especially the p-type conduction is more favourable.

  16. Variations of thermospheric composition according to AE-C data and CTIP modelling

    Directory of Open Access Journals (Sweden)

    H. Rishbeth

    2004-01-01

    Full Text Available Data from the Atmospheric Explorer C satellite, taken at middle and low latitudes in 1975-1978, are used to study latitudinal and month-by-month variations of thermospheric composition. The parameter used is the "compositional Ρ-parameter", related to the neutral atomic oxygen/molecular nitrogen concentration ratio. The midlatitude data show strong winter maxima of the atomic/molecular ratio, which account for the "seasonal anomaly" of the ionospheric F2-layer. When the AE-C data are compared with the empirical MSIS model and the computational CTIP ionosphere-thermosphere model, broadly similar features are found, but the AE-C data give a more molecular thermosphere than do the models, especially CTIP. In particular, CTIP badly overestimates the winter/summer change of composition, more so in the south than in the north. The semiannual variations at the equator and in southern latitudes, shown by CTIP and MSIS, appear more weakly in the AE-C data. Magnetic activity produces a more molecular thermosphere at high latitudes, and at mid-latitudes in summer. Key words. Atmospheric composition and structure (thermosphere – composition and chemistry

  17. Variations of thermospheric composition according to AE-C data and CTIP modelling

    Directory of Open Access Journals (Sweden)

    H. Rishbeth

    2004-01-01

    Full Text Available Data from the Atmospheric Explorer C satellite, taken at middle and low latitudes in 1975-1978, are used to study latitudinal and month-by-month variations of thermospheric composition. The parameter used is the "compositional Ρ-parameter", related to the neutral atomic oxygen/molecular nitrogen concentration ratio. The midlatitude data show strong winter maxima of the atomic/molecular ratio, which account for the "seasonal anomaly" of the ionospheric F2-layer. When the AE-C data are compared with the empirical MSIS model and the computational CTIP ionosphere-thermosphere model, broadly similar features are found, but the AE-C data give a more molecular thermosphere than do the models, especially CTIP. In particular, CTIP badly overestimates the winter/summer change of composition, more so in the south than in the north. The semiannual variations at the equator and in southern latitudes, shown by CTIP and MSIS, appear more weakly in the AE-C data. Magnetic activity produces a more molecular thermosphere at high latitudes, and at mid-latitudes in summer.

    Key words. Atmospheric composition and structure (thermosphere – composition and chemistry

  18. Multielement Determination of Major-to Ultratrace Elements in a Cabbage, Spinach, and the Japanese Radish by ICP-AES After Acid Digestion

    OpenAIRE

    畑山, 友紀; 奴田原, 杏奈; 藤井, 和美; 西島, 基弘; ハタヤマ, ユキ; ヌタハラ, アンナ; フジイ, カズミ; ニシジマ, モトヒロ; Yuki, Hatayama; anna, Nutahara; Kazumi, Fujii; Motohiro, Nishijima

    2011-01-01

    A multi-element determination in a cabbage, spinach, and the Japanese radish was carried out by inductively coupled plasma atomic emission spectrometry (ICP). We investigated whether there was a difference in content according to the part of the vegetables. The dried vegetables (0.5g) were digested with nitric acid and with hydrogen peroxide acid in a resolution device As a result, about 9 elements were successfully determined. The values of the coefficient of variance for part interval by ea...

  19. Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion.

    Science.gov (United States)

    Heilmann, Jens; Boulyga, Sergei F; Heumann, Klaus G

    2004-09-01

    Inductively coupled plasma isotope-dilution mass spectrometry (ICP-IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel fuel, and heating oil. For direct injection a micro-emulsion consisting of the corresponding organic sample and an aqueous 34S-enriched spike solution with additions of tetrahydronaphthalene and Triton X-100, was prepared. The ICP-MS parameters were optimized with respect to high sulfur ion intensities, low mass-bias values, and high precision of 32S/34S ratio measurements. For validation of the DIHEN-ICP-IDMS method two certified gas oil reference materials (BCR 107 and BCR 672) were analyzed. For comparison a wet-chemical ICP-IDMS method was applied with microwave-assisted digestion using decomposition of samples in a closed quartz vessel inserted into a normal microwave system. The results from both ICP-IDMS methods agree well with the certified values of the reference materials and also with each other for analyses of other samples. However, the standard deviation of DIHEN-ICP-IDMS was about a factor of two higher (5-6% RSD at concentration levels above 100 mircog g(-1)) compared with those of wet-chemical ICP-IDMS, mainly due to inhomogeneities of the micro-emulsion, which causes additional plasma instabilities. Detection limits of 4 and 18 microg g(-1) were obtained for ICP-IDMS in connection with microwave-assisted digestion and DIHEN-ICP-IDMS, respectively, with a sulfur background of the used Milli-Q water as the main limiting factor for both methods.

  20. Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion

    Energy Technology Data Exchange (ETDEWEB)

    Heilmann, Jens; Boulyga, Sergei F.; Heumann, Klaus G. [Johannes Gutenberg-University, Institute of Inorganic Chemistry and Analytical Chemistry, Mainz (Germany)

    2004-09-01

    Inductively coupled plasma isotope-dilution mass spectrometry (ICP-IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel fuel, and heating oil. For direct injection a micro-emulsion consisting of the corresponding organic sample and an aqueous {sup 34}S-enriched spike solution with additions of tetrahydronaphthalene and Triton X-100, was prepared. The ICP-MS parameters were optimized with respect to high sulfur ion intensities, low mass-bias values, and high precision of {sup 32}S/{sup 34}S ratio measurements. For validation of the DIHEN-ICP-IDMS method two certified gas oil reference materials (BCR 107 and BCR 672) were analyzed. For comparison a wet-chemical ICP-IDMS method was applied with microwave-assisted digestion using decomposition of samples in a closed quartz vessel inserted into a normal microwave system. The results from both ICP-IDMS methods agree well with the certified values of the reference materials and also with each other for analyses of other samples. However, the standard deviation of DIHEN-ICP-IDMS was about a factor of two higher (5-6% RSD at concentration levels above 100 {mu}g g{sup -1}) compared with those of wet-chemical ICP-IDMS, mainly due to inhomogeneities of the micro-emulsion, which causes additional plasma instabilities. Detection limits of 4 and 18 {mu}g g{sup -1} were obtained for ICP-IDMS in connection with microwave-assisted digestion and DIHEN-ICP-IDMS, respectively, with a sulfur background of the used Milli-Q water as the main limiting factor for both methods. (orig.)

  1. Enhanced ATM Security using Biometric Authentication and Wavelet Based AES

    Directory of Open Access Journals (Sweden)

    Sreedharan Ajish

    2016-01-01

    Full Text Available The traditional ATM terminal customer recognition systems rely only on bank cards, passwords and such identity verification methods are not perfect and functions are too single. Biometrics-based authentication offers several advantages over other authentication methods, there has been a significant surge in the use of biometrics for user authentication in recent years. This paper presents a highly secured ATM banking system using biometric authentication and wavelet based Advanced Encryption Standard (AES algorithm. Two levels of security are provided in this proposed design. Firstly we consider the security level at the client side by providing biometric authentication scheme along with a password of 4-digit long. Biometric authentication is achieved by considering the fingerprint image of the client. Secondly we ensure a secured communication link between the client machine to the bank server using an optimized energy efficient and wavelet based AES processor. The fingerprint image is the data for encryption process and 4-digit long password is the symmetric key for the encryption process. The performance of ATM machine depends on ultra-high-speed encryption, very low power consumption, and algorithmic integrity. To get a low power consuming and ultra-high speed encryption at the ATM machine, an optimized and wavelet based AES algorithm is proposed. In this system biometric and cryptography techniques are used together for personal identity authentication to improve the security level. The design of the wavelet based AES processor is simulated and the design of the energy efficient AES processor is simulated in Quartus-II software. Simulation results ensure its proper functionality. A comparison among other research works proves its superiority.

  2. ICP-oa TOFMS utilisation to determine the Gd isotopic abundance in gadolinium nitrate

    International Nuclear Information System (INIS)

    Dragomir, M.; Ohai, D.; Dumitrescu, I.; Furtuna, I.

    2010-01-01

    This paper is describes the development of a method that should permit the determination of isotope abundance of gadolinium in gadolinium nitrate, used as burnable poison at Cernavoda NPP. To determine the isotopic abundance of gadolinium the inductively coupled plasma orthogonal acceleration time-of-flight mass spectrometer (ICP-oa TOFMS) was used. The ICP-oa TOFMS allows the elimination of noise associated with instrumental drift and instability (flicker noise). The absence of flicker noise in the ICP-oa TOFMS means that the isotope ratios can be measured up to the statistical limit of ion counting. With TOFMS, each spectrum acquired represents signals from ions extracted from the plasma during the same time interval, formed from identical plasma and sample introduction events. Therefore, the ICP-oa TOFMS, Optimass 8000, has been successfully used for isotope ratio measurements of Gd in gadolinium nitrate [Gd (NO 3 ) 3 x 6H 2 O] sample solutions. (authors)

  3. Attacks and countermeasures on AES and ECC

    DEFF Research Database (Denmark)

    Tange, Henrik; Andersen, Birger

    2013-01-01

    AES (Advanced Encryption Standard) is widely used in LTE and Wi-Fi communication systems. AES has recently been exposed to new attacks which have questioned the overall security of AES. The newest attack is a so called biclique attack, which is using the fact that the content of the state array...

  4. Auroral Electrojet Index Designed to Provide a Global Measure, Hourly Intervals, of Auroral Zone Magnetic Activity

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Auroral Electrojet (AE) index is designed to provide a global quantitative measure of auroral zone magnetic activity produced by enhanced ionospheric currents...

  5. Implementing AES via an Actively/Covertly Secure Dishonest-Majority MPC Protocol

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Keller, Marcel; Keller, Enrique

    2012-01-01

    , but produces significant performance enhancements; the second enables us to perform bit-wise operations in characteristic two fields. As a bench mark application we present the evaluation of the AES cipher, a now standard bench marking example for multi-party computation. We need examine two different...

  6. Effect of Calcium Oxide on the Crushing Strength, Reduction, and Smelting Performance of High-Chromium Vanadium–Titanium Magnetite Pellets

    Directory of Open Access Journals (Sweden)

    Gongjin Cheng

    2017-05-01

    Full Text Available The effect of calcium oxide on the crushing strength, reduction, and smelting performance of high-chromium vanadium–titanium magnetite pellets (HCVTMP was studied in this work. The main characterization methods of an electronic universal testing machine (EUTM, X-ray fluorescent (XRF, inductively-coupled plasma-atomic emission spectroscopy (ICP-AES, X-ray diffraction (XRD, and scanning electron microscope-energy disperse spectroscopy (SEM-EDS were employed. The crushing strength was affected by the mineral phases generated during oxidative baking and the subsequently-formed pellet microstructures owing to CaO addition. The reduction and smelting properties of HCVTMP with different CaO additives were measured and characterized with different softening-melting-dripping indices. Although HCVTMP showed the highest crushing strength with CaO addition of ca. 2 wt %, more CaO addition may be needed to achieve high permeability of the furnace burdens and a good separation condition of the slag and melted iron. In the formation process of the slag and melted iron, it can be determined that CaO could have a relationship with the transformation behavior of Cr, V, and Ti to some extent, with respect to the predominant chemical composition analysis of ICP-AES and XRF. With the microscopic examination, the restraining formation of Ti(C,N and the promoting formation of CaTiO3 are in accordance with the improved melting-dripping indices, including the decrease of the maximum external static load and gas permeability, and the increase of the melting-dripping zone and dripping difficulty.

  7. Considerations of particle vaporization and analyte diffusion in single-particle inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Ho, Koon-Sing; Lui, Kwok-On; Lee, Kin-Ho; Chan, Wing-Tat

    2013-01-01

    The intensity of individual gold nanoparticles with nominal diameters of 80, 100, 150, and 200 nm was measured using single-particle inductively coupled plasma-mass spectrometry (ICP-MS). Since the particles are not perfectly monodisperse, a distribution of ICP-MS intensity was obtained for each nominal diameter. The distribution of particle mass was determined from the transmission electron microscopy (TEM) image of the particles. The distribution of ICP-MS intensity and the distribution of particle mass for each nominal diameter were correlated to give a calibration curve. The calibration curves are linear, but the slope decreases as the nominal diameter increases. The reduced slope is probably due to a smaller degree of vaporization of the large particles. In addition to the degree of particle vaporization, the rate of analyte diffusion in the ICP is an important factor that determines the measured ICP-MS intensity. Simulated ICP-MS intensity versus particle size was calculated using a simple computer program that accounts for the vaporization rate of the gold nanoparticles and the diffusion rate and degree of ionization of the gold atoms. The curvature of the simulated calibration curves changes with sampling depth because the effects of particle vaporization and analyte diffusion on the ICP-MS intensity are dependent on the residence time of the particle in the ICP. Calibration curves of four hypothetical particles representing the four combinations of high and low boiling points (2000 and 4000 K) and high and low analyte diffusion rates (atomic masses of 10 and 200 Da) were calculated to further illustrate the relative effects of particle vaporization and analyte diffusion. The simulated calibration curves show that the sensitivity of single-particle ICP-MS is smaller than that of the ICP-MS measurement of continuous flow of standard solutions by a factor of 2 or more. Calibration using continuous flow of standard solution is semi-quantitative at best. An

  8. A More Compact AES

    OpenAIRE

    Canright, David; Osvik, Dag Arne

    2009-01-01

    We explore ways to reduce the number of bit operations required to implement AES. One way involves optimizing the composite field approach for entire rounds of AES. Another way is integrating the Galois multiplications of MixColumns with the linear transformations of the S-box. Combined with careful optimizations, these reduce the number of bit operations to encrypt one block by 9.0%, compared to earlier work that used the composite field only in the S-box. For decryption, ...

  9. A high-resolution spectropolarimetric survey of Herbig Ae/Be stars - II. Rotation

    Science.gov (United States)

    Alecian, E.; Wade, G. A.; Catala, C.; Grunhut, J. H.; Landstreet, J. D.; Böhm, T.; Folsom, C. P.; Marsden, S.

    2013-02-01

    We report the analysis of the rotational properties of our sample of Herbig Ae/Be (HAeBe) and related stars for which we have obtained high-resolution spectropolarimetric observations. Using the projected rotational velocities measured at the surface of the stars, we have calculated the angular momentum of the sample and plotted it as a function of age. We have then compared the angular momentum and the v sin i distributions of the magnetic to the non-magnetic HAeBe stars. Finally, we have predicted v sin i of the non-magnetic, non-binary (`normal') stars in our sample when they reach the zero-age main sequence (ZAMS), and compared them to various catalogues of v sin i of main-sequence stars. First, we observe that magnetic HAeBe stars are much slower rotators than normal stars, indicating that they have been more efficiently braked than the normal stars. In fact, the magnetic stars have already lost most of their angular momentum, despite their young ages (lower than 1 Myr for some of them). Secondly, our analysis suggests that the low-mass (1.5 5 M⊙) are losing angular momentum. We propose that winds, which are expected to be stronger in massive stars, are at the origin of this phenomenon.

  10. Magnetic fields of Herbig Ae/Be stars

    Directory of Open Access Journals (Sweden)

    Hubrig S.

    2014-01-01

    Full Text Available We report on the status of our spectropolarimetric studies of Herbig Ae/Be stars carried out during the last years. The magnetic field geometries of these stars, investigated with spectropolarimetric time series, can likely be described by centred dipoles with polar magnetic field strengths of several hundred Gauss. A number of Herbig Ae/Be stars with detected magnetic fields have recently been observed with X-shooter in the visible and the near-IR, as well as with the high-resolution near-IR spectrograph CRIRES. These observations are of great importance to understand the relation between the magnetic field topology and the physics of the accretion flow and the accretion disk gas emission.

  11. AE/flaw characterization for nuclear pressure vessels

    International Nuclear Information System (INIS)

    Hutton, P.H.; Kurtz, R.J.; Pappas, R.A.

    1984-01-01

    This chapter discusses the use of acoustic emission (AE) detected during continuous monitoring to identify and evaluate growing flaws in pressure vessels. Off-reactor testing and on-reactor testing are considered. Relationships for identifying acoustic emission (AE) from crack growth and using the AE data to estimate flaw severity have been developed experimentally by laboratory testing. The purpose of the off-reactor vessel test is to evaluate AE monitoring/interpretation methodology on a heavy section steel vessel under simulated reactor operating conditions. The purpose of on-reactor testing is to evaluate the capability of a monitor system to function in the reactor environment, calibrate the ability to detect AE signals, and to demonstrate that a meaningful criteria can be established to prevent false alarms. An expanded data base is needed from application testing and methodology standardization

  12. Current role of ICP-MS in clinical toxicology and forensic toxicology: a metallic profile.

    Science.gov (United States)

    Goullé, Jean-Pierre; Saussereau, Elodie; Mahieu, Loïc; Guerbet, Michel

    2014-08-01

    As metal/metalloid exposure is inevitable owing to its omnipresence, it may exert toxicity in humans. Recent advances in metal/metalloid analysis have been made moving from flame atomic absorption spectrometry and electrothermal atomic absorption spectrometry to the multi-elemental inductively coupled plasma (ICP) techniques as ICP atomic emission spectrometry and ICP-MS. ICP-MS has now emerged as a major technique in inorganic analytical chemistry owing to its flexibility, high sensitivity and good reproducibility. This in depth review explores the ICP-MS metallic profile in human toxicology. It is now routinely used and of great importance, in clinical toxicology and forensic toxicology to explore biological matrices, specifically whole blood, plasma, urine, hair, nail, biopsy samples and tissues.

  13. Analysis of twenty five impurities in uranium matrix by ICP-MS with iron measurement optimized by using reaction collision cell, cold plasma or medium resolution.

    Science.gov (United States)

    Quemet, Alexandre; Brennetot, Rene; Chevalier, Emilie; Prian, Edwina; Laridon, Anne-Laure; Mariet, Clarisse; Fichet, Pascal; Laszak, Ivan; Goutelard, Florence

    2012-09-15

    An analytical procedure was developed to determine the concentration of 25 impurities (Li, Be, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Zr, Mo, Ag, Cd, In, Sm, Eu, Gd, Dy, W, Pb, Bi and Th) in a uranium matrix using the quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS). The dissolution of U(3)O(8) powder was made with a mixture of hydrochloric acid and nitric acid. Then, a selective separation of uranium using the UTEVA column was used before measurement by Q-ICP-MS. The procedure developed was verified using the Certified Reference Material "Morille". The analytical results agree well except for 5 elements where values are underestimated (Li, Be, In, Pb and Bi). Among the list of impurities, iron was particularly investigated because it is well known that this element possesses a polyatomic interference that increases the detection limit. A comparison between iron detection limits obtained with different methods was performed. Iron polyatomic interference was at least reduced, or at best entirely resolved in some cases, by using the cold plasma or the collision/reaction cell with several gases (He, NH(3) and CH(4)). High-resolution ICP-MS was used to compare the results obtained. A detection limit as low as 8 ng L(-1) was achieved. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Comparative study for toxic elements determination in air particulate reference material by INAA, CCT-ICP-MS, and ICP-MS

    International Nuclear Information System (INIS)

    Lim, J.M.; Lee, J.H.; Kim, K.H.; Moon, J.H.; Chung, Y.S.

    2005-01-01

    Although toxic elements are minor components in the atmospheric environment, they play a significant role as important marker for atmospheric science such as risk assessment, long-range transfer study, and source apportionment. Therefore, the techniques, which allow accurate and fast elemental analysis with a minimum pre-treatment, are very important. INAA has a main advantage of non-destruction of air particulate samples, while inductively Coupled plasma with mass spectrometry (ICP-MS) encounters the most significant difficulties in pre-treatment (digestion, fusion, and dilution) and polyatomic spectral interferences for interest toxic elements, Although INAA is still reference method, a number of factors (disadvantages of cost, complexity of the instruments, and scarcity of nuclear reactor) limit its applications. To date, the use of collision cell technology ICP-MS (CCT-ICP-MS) is recommended instead of typical ICP-MS for the analysis of the toxic elements; this is because CCT-ICP-MS technique prevents polyatomic spectral interferences despite of contamination and volatile effects. In this study, a number of toxic elements in reference material, NIST SRM 2783 (air particulate on filter media) were determined by INAA, CCT-ICP-MS, and ICP-MS. For both ICP methods, the filters were decomposed by microwave digestion with 5mL nitric acid. The analytical results by three methods were compared with certificated data; the INAA results showed the most accurate and precise data sets for all target elements among three methods. In detail, the deviation between analytical results and SRM's by INAA fell below 10% for all elements excluding As (14%), while those by CCT-ICP-MS were about 20%. For ICP-MS, the result does not agree with certificated data for several elements, because polyatomic spectral interference (due to 40 Ar 35 Cl, 40 Ar 23 Na, and 35 Cl 16 O) generate positive error of analytical result for As, Cu, and V. Based on our result, INAA is still one of the most

  15. Trace elemental analysis of leaching solutions of hijiki seaweeds by a portable total reflection X-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Liu, Ying; Imashuku, Susumu; Kawai, Jun

    2014-01-01

    A portable total reflection X-ray fluorescence spectrometer (TXRF) was used to analyze leaching solutions of hijiki seaweeds. S, Cl, K, Ca, Ti, Fe, Ni, As and Br were detected in the solutions. Arsenic quantification results were compared to those from ICP-AES. The TXRF quantification results of arsenic were not significantly different from those of ICP-AES, as two-way analysis of variance (ANOVA) method was applied to the significance test. This kind of small and high sensitive TXRF spectrometer can be used in food quality and environmental pollution investigation. (author)

  16. LASER ABLATION-INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY STUDY AT THE 222-S LABORATORY USING HOT-CELL GLOVE BOX PROTOTYPE SYSTEM

    International Nuclear Information System (INIS)

    Lockrem, L.L.; Owens, J.W.; Seidel, C.M.

    2009-01-01

    This report describes the installation, testing and acceptance of the Waste Treatment and Immobilization Plant procured laser ablation-inductively coupled plasma-atomic emission spectroscopy (LA-ICP-AES) system for remotely analyzing high-level waste samples in a hot cell environment. The 2005-003; ATS MP 1027, Management Plan for Waste Treatment Plant Project Work Performed by Analytical Technical Services. The APD group at the 222-S laboratory demonstrated acceptable turnaround time (TAT) and provide sufficient data to assess sensitivity, accuracy, and precision of the LA-ICP-AES method

  17. Removal efficiency of multiple poly- and perfluoroalkyl substances (PFASs) in drinking water using granular activated carbon (GAC) and anion exchange (AE) column tests.

    Science.gov (United States)

    McCleaf, Philip; Englund, Sophie; Östlund, Anna; Lindegren, Klara; Wiberg, Karin; Ahrens, Lutz

    2017-09-01

    Poly- and perfluoroalkyl substances (PFASs) have been detected in drinking water at relatively high concentrations throughout the world which has led to implementation of regulatory guidelines for specific PFASs in drinking water in several European countries and in the U.S. The Swedish National Food Agency has determined that the drinking water of over one third of the country's municipal consumers is at risk or already affected by PFAS contamination. The present study investigated the effects of perfluorocarbon chain length, functional group and isomer structure (branched or linear) on removal of multiple PFASs using granular activated carbon (GAC, Filtrasorb ® 400) and anion exchange (AE, Purolite ® A600) column experiments. The removal of 14 different PFASs, i.e. the C 3 C 11 , C 14 perfluoroalkyl carboxylic acids (PFCAs) (PFBA, PFPeA, PFHxA, PFHpA, PFOA, PFNA, PFDA, PFUnDA, PFDoDA, PFTeDA), perfluorooctane sulfonamide (FOSA), and the C 4 , C 6 , C 8 perfluoroalkyl sulfonic acids (PFSAs) (PFBS, PFHxS, PFOS), was monitored for a 217 day period. The results indicate the selective nature of PFAS removal as the absorbents are loaded with PFASs and dissolved organic carbon (DOC). A clear relationship between perfluorocarbon chain length and removal efficiency of PFASs using GAC and AE was found while PFASs with sulfonate functional groups displayed greater removal efficiency than those with carboxylate groups. Similarly, time to column breakthrough increased with increasing perfluorocarbon chain length and was greater for the PFSAs than the PFCAs for both GAC and AE. Shorter carbon chained PFASs such as PFBA, PFPeA, PFHxA showed desorption behavior and long-chained PFASs showed increased removal towards the end of the experiment indicating agglomeration or micelle development. Linear isomers of PFOS, PFHxS, and perfluorooctane sulfonamide (FOSA) had greater column removal efficiencies using GAC (and also for AE at greater bed volume throughput) than the branched

  18. Acoustic emission measurements in petroleum-related rock mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Unander, Tor Erling

    2002-07-01

    Acoustic emission activity in rock has usually been studied in crystalline rock, which reflects that rock mechanics has also mostly been occupied with such rocks in relations to seismology, mining and tunneling. On the other hand, petroleum-related rock mechanics focuses on the behaviour of sedimentary rock. Thus, this thesis presents a general study of acoustic emission activity in sedimentary rock, primarily in sandstone. Chalk, limestone and shale have also been tested, but to much less degree because the AE activity in these materials is low. To simplify the study, pore fluids have not been used. The advent of the personal computer and computerized measuring equipment have made possible new methods both for measuring and analysing acoustic emissions. Consequently, a majority of this work is devoted to the development and implementation of new analysis techniques. A broad range of topics are treated: (1) Quantification of the AE activity level, assuming that the event rate best represents the activity. An algorithm for estimating the event rate and a methodology for objectively describing special changes in the activity e.g., onset determination, are presented. (2) Analysis of AE waveform data. A new method for determining the source energy of an AE event is presented, and it is shown how seismic source theory can be used to analyze even intermediate quality data. Based on these techniques, it is shown that a major part of the measured AE activity originates from a region close to the sensor, not necessarily representing the entire sample. (3) An improved procedure for estimating source locations is presented. The main benefit is a procedure that better handles arrival time data with large errors. Statistical simulations are used to quantify the uncertainties in the locations. The analysis techniques are developed with the application to sedimentary rock in mind, and in two articles, the techniques are used in the study of such materials. The work in the first

  19. Simultaneous determination of carbohydrates, carboxylic acids, alcohols, and metals in foods by high-performance liquid chromatography inductively coupled plasma atomic emission spectrometry.

    Science.gov (United States)

    Paredes, Eduardo; Maestre, Salvador E; Prats, Soledad; Todolí, José L

    2006-10-01

    The applicability of the HPLC-ICP-AES coupling for the simultaneous determination of carbohydrates, carboxylic acids, alcohols, and metals in a single chromatographic run has been demonstrated in the present work. Five saccharides, glucose, fructose, sucrose, sorbitol, and lactose; five carboxylic acids, citric, tartaric, malic, lactic, and acetic; and three alcohols, glycerol, ethanol, and methanol, have been determined. A H+ cation exchange column has been used to separate these compounds. The chromatograms have been obtained by monitoring the carbon emission signal at 193.09 nm. The results obtained by HPLC-ICP-AES have been compared against those found with conventional detection systems (i.e., refractive index, UV, and photodyode array detectors). The HPLC-ICP-AES method has shown the following features: (i) organic compounds and metals can be simultaneously determined; (ii) the detection method is universal; (iii) for nonvolatile organic compounds, a complete calibration line can be obtained from a single injection; and (iv) it provides absolute limits of detection similar to or lower than those found with conventional detection systems (i.e., on the order of several tens of nanograms of organic compound). The methodology has been validated through the analysis of food samples such as juices, isotonic beverages, wines, and a certified nonfat milk powder sample.

  20. Auroral Electrojet Index Designed to Provide a Global Measure, l-minute Intervals, of Auroral Zone Magnetic Activity

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Auroral Electrojet index (AE) is designed to provide a global quantitative measure of auroral zone magnetic activity produced by enhanced ionospheric currents...

  1. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†

    Science.gov (United States)

    Pröfrock, Daniel; Irrgeher, Johanna; Prohaska, Thomas

    2016-01-01

    The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3–0.5% (uc,rel), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement uc,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%). PMID:27812369

  2. Comparison of 4 analytical techniques based on atomic spectrometry for the determination of total tin in canned foodstuffs

    OpenAIRE

    2011-01-01

    Abstract Different techniques for the determination of total tin in beverage and canned food by atomic spectrometry were compared. The performance characteristics of Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Hydride Generation Inductively Coupled Plasma Atomic Emission Spectrometry (HG-ICP-AES), Electrothermal Atomization Atomic Absorption Spectrometry (ETA-AAS) and Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) were determined in term of linearity, ...

  3. Some physico-chemical properties and mineral contents of sweet ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-06-17

    Jun 17, 2009 ... contents of sweet cherry (Prunus avium L.) type grown in Konya .... Working conditions of ICP-AES. Instrument: ICP-AES ... The volume of fruit (V) and fruit density (Pt), were determined using the liquid ... These differences can.

  4. Determination of trace Np and Pu by ICP-MS with extraction chromatography in emergency situations

    International Nuclear Information System (INIS)

    Yanqin, Ji; Qing, Tian; Baoming, Shen; Xianzhang, Shao

    2008-01-01

    Full text: An accurate determination of radioculides from various sources in the environmental samples is essential for assessment of the potential hazards and suitable countermeasures both in case of accidents, authorised release and routine surveillance. However, the concentrationof neptunium and plutonium is extremely low in environmental samples, and such samples have a complex matrix composition, which is to be taken into account for a proper analysis. Conventional radiochemical methods such as alpha spectrometry, neutron activation analysis, liquid, liquid scintillation system, fission track and gamma spectrometry for the quantitative determination of neptunium and plutonium often require complicated and time-consuming sample preparation and separation procedures. Due to the large amount of the complex and often unknown matrix, the analysis may also be covered by naturally occurring radionuclides. With the development of new analysis techniques, non-radioactive methods are increasingly used for the determination of trace or ultra-trace radionuclides in environmental samples. Inductively coupled plasma mass spectrometry (ICP-MS) is one of the most suitable analysis techniques for the measurement of the long-lived radionuclides with its high sensitivity, low detection limits, short analysis time, less chemical interferences and multi-elemental capability. The throughput is therefore very high (approx.100 samples a day). The main objective of the present study was to set up of a simple, fast separation procedure to measure Np and Pu in the environmental samples ICP-MS. An unique extraction chromatographic column (TOA: tri-n-octylamine on Teflon powder) with a two-stage sample loading was prepared to separate Np and Pu from the environmental matrix. Np and Pu were efficiently retained in 4 M HNO 3 medium on the column and easiy eluted with 0.02 M oxalic acid 0.16 M HNO 3 at 95 C degree. The separated solutions were free from most of the matrix elements and were

  5. An exploration hydrogeochemical study at the giant Pebble porphyry Cu-Au-Mo deposit, Alaska, USA, using high-resolution ICP-MS

    Science.gov (United States)

    Eppinger, Robert G.; Fey, David L.; Giles, Stuart A.; Kelley, Karen D.; Smith, Steven M.

    2012-01-01

    A hydrogeochemical study using high resolution ICP-MS was undertaken at the giant Pebble porphyry Cu-Au-Mo deposit and surrounding mineral occurrences. Surface water and groundwater samples from regional background and the deposit area were collected at 168 sites. Rigorous quality control reveals impressive results at low nanogram per litre (ng/l) levels. Sites with pH values below 5.1 are from ponds in the Pebble West area, where sulphide-bearing rubble crop is thinly covered. Relative to other study area waters, anomalous concentrations of Cu, Cd, K, Ni, Re, the REE, Tl, SO42− and F− are present in water samples from Pebble West. Samples from circum-neutral waters at Pebble East and parts of Pebble West, where cover is much thicker, have anomalous concentrations of Ag, As, In, Mn, Mo, Sb, Th, U, V, and W. Low-level anomalous concentrations for most of these elements were also found in waters surrounding nearby porphyry and skarn mineral occurrences. Many of these elements are present in low ng/l concentration ranges and would not have been detected using traditional quadrupole ICP-MS. Hydrogeochemical exploration paired with high resolution ICP-MS is a powerful new tool in the search for concealed deposits.

  6. Comportamento de Aedes albopictus e de Ae. scapularis adultos (Diptera: Culicidae no Sudeste do Brasil Adults Aedes albopictus and Ae. scapularis behavior (Diptera: Culidae in Southeastern Brazil

    Directory of Open Access Journals (Sweden)

    Oswaldo Paulo Forattini

    2000-10-01

    January 2000 observations were carried out through systematic collections with human bait, environment aspirations and Shannon trap utilization. Synanthropy was estimated by the Nuorteva index and synanthropic ratios. RESULTS: The 87 collections with human bait yield 872 females adults. Williams' means, multiplied by 100, were 118 and 21 for Ae. albopictus at the 7 AM-6PM and 6PM-8PM hours, respectively, 100 and 106 for Ae. scapularis at the same timetable but there was an evening peak. Through environmental aspirations, a total of 1,124 adults samples was collected, 226 Ae. albopictus samples and 898 Ae. scapularis samples. The period between the months of January-May was the one with higher yield for both mosquitoes. There was no Ae. albopictus in the Shannon trap operated inside the adjacent forest. Regarding the sinanthropy, that culicid showed the higher index values, while Ae. scapularis was ubiquitous. CONCLUSIONS: The data obtained allows to form the hypothesis that Ae. scapularis females may have a diapause phase in the resting places and after that period they will retake the hematophagy habit. That might explain the higher activity at the humen bait during the dry months, corresponding to the period of July-October.

  7. ICP-MS with hexapole collision cell for isotope ratio measurements of Ca, Fe, and Se

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, S.F. [Radiation Physics and Chemistry Problems Inst., Minsk (Belarus); Becker, J.S. [Central Department for Analytical Chemistry, Research Centre Juelich (Germany)

    2001-07-01

    To avoid mass interferences on analyte ions caused by argon ions and argon molecular ions via reactions with collision gases, an rf hexapole filled with helium and hydrogen has been used in inductively coupled plasma mass spectrometry (ICP-MS), and its performance has been studied. Up to tenfold improvement in sensitivity was observed for heavy elements (m > 100 u), because of better ion transmission through the hexapole ion guide. A reduction of argon ions Ar{sup +} and the molecular ions of argon ArX{sup +} (X = O, Ar) by up to three orders of magnitude was achieved in a hexapole collision cell of an ICP-MS (''Platform ICP'', Micromass, Manchester, UK) as a result of gas-phase reactions with hydrogen when the hexapole bias (HB) was set to 0 V; at an HB of 1.6 V argon, and argon-based ions of masses 40 u, 56 u, and 80 u, were reduced by approximately four, two, and five orders of magnitude, respectively. The signal-to-noise ratio {sup 80}Se/ {sup 40}Ar{sub 2}{sup +} was improved by more than five orders of magnitude under optimized experimental conditions. Dependence of mass discrimination on collision-cell properties was studied in the mass range 10 u (boron) to 238 u (uranium). Isotopic analysis of the elements affected by mass-spectrometric interference, Ca, Fe, and Se, was performed using a Meinhard nebulizer and an ultrasonic nebulizer (USN). The measured isotope ratios were comparable with tabulated values from IUPAC. Precision of 0.26%, 0.19%, and 0.12%, respectively, and accuracy of 0.13% 0.25%, and 0.92%, respectively, was achieved for isotope ratios {sup 44}Ca/ {sup 40}Ca and {sup 56}Fe/{sup 57}Fe in 10 {mu}g L{sup -1} solution nebulized by means of a USN and for {sup 78}Se/{sup 80}Se in 100 {mu}g L{sup -1} solution nebulized by means of a Meinhard nebulizer. (orig.)

  8. Determination of rhenium traces in river water by Q-ICP-MS and HR-ICP-MS

    International Nuclear Information System (INIS)

    Uchida, S.; Tagami, K.; Saito, M.

    2003-01-01

    A simple separation method was applied to determine rhenium in river water using Q-ICP-MS and HR-ICP-MS. Re was concentrated from 420-925 ml river water using a TEVA resin minicolumn. Such extraction using a resin could separate Re from most sample matrices and trace elements. Almost 100% recovery was found throughout the method as determined with radioactive multitracers. The HR-ICP-MS was also used for the direct determination because of its low detection limit for Re (0.007 pg/ml). The Re concentration in the river water samples ranged from 0.9 to 6.5 pg/ml and the three analysis results showed good agreement with each other. (author)

  9. Application of a microwave-based desolvation system for multi-elemental analysis of wine by inductively coupled plasma based techniques

    Energy Technology Data Exchange (ETDEWEB)

    Grindlay, Guillermo [Department of Analytical Chemistry, Nutrition and Food Sciences, University of Alicante, P.O. Box 99, 03080 Alicante (Spain)], E-mail: guillermo.grindlay@ua.es; Mora, Juan; Maestre, Salvador; Gras, Luis [Department of Analytical Chemistry, Nutrition and Food Sciences, University of Alicante, P.O. Box 99, 03080 Alicante (Spain)

    2008-11-23

    Elemental wine analysis is often required from a nutritional, toxicological, origin and authenticity point of view. Inductively coupled plasma based techniques are usually employed for this analysis because of their multi-elemental capabilities and good limits of detection. However, the accurate analysis of wine samples strongly depends on their matrix composition (i.e. salts, ethanol, organic acids) since they lead to both spectral and non-spectral interferences. To mitigate ethanol (up to 10% w/w) related matrix effects in inductively coupled plasma atomic emission spectrometry (ICP-AES), a microwave-based desolvation system (MWDS) can be successfully employed. This finding suggests that the MWDS could be employed for elemental wine analysis. The goal of this work is to evaluate the applicability of the MWDS for elemental wine analysis in ICP-AES and inductively coupled plasma mass spectrometry (ICP-MS). For the sake of comparison a conventional sample introduction system (i.e. pneumatic nebulizer attached to a spray chamber) was employed. Matrix effects, precision, accuracy and analysis throughput have been selected as comparison criteria. For ICP-AES measurements, wine samples can be directly analyzed without any sample treatment (i.e. sample dilution or digestion) using pure aqueous standards although internal standardization (IS) (i.e. Sc) is required. The behaviour of the MWDS operating with organic solutions in ICP-MS has been characterized for the first time. In this technique the MWDS has shown its efficiency to mitigate ethanol related matrix effects up to concentrations of 1% (w/w). Therefore, wine samples must be diluted to reduce the ethanol concentration up to this value. The results obtained have shown that the MWDS is a powerful device for the elemental analysis of wine samples in both ICP-AES and ICP-MS. In general, the MWDS has some attractive advantages for elemental wine analysis when compared to a conventional sample introduction system such

  10. Application of a microwave-based desolvation system for multi-elemental analysis of wine by inductively coupled plasma based techniques

    International Nuclear Information System (INIS)

    Grindlay, Guillermo; Mora, Juan; Maestre, Salvador; Gras, Luis

    2008-01-01

    Elemental wine analysis is often required from a nutritional, toxicological, origin and authenticity point of view. Inductively coupled plasma based techniques are usually employed for this analysis because of their multi-elemental capabilities and good limits of detection. However, the accurate analysis of wine samples strongly depends on their matrix composition (i.e. salts, ethanol, organic acids) since they lead to both spectral and non-spectral interferences. To mitigate ethanol (up to 10% w/w) related matrix effects in inductively coupled plasma atomic emission spectrometry (ICP-AES), a microwave-based desolvation system (MWDS) can be successfully employed. This finding suggests that the MWDS could be employed for elemental wine analysis. The goal of this work is to evaluate the applicability of the MWDS for elemental wine analysis in ICP-AES and inductively coupled plasma mass spectrometry (ICP-MS). For the sake of comparison a conventional sample introduction system (i.e. pneumatic nebulizer attached to a spray chamber) was employed. Matrix effects, precision, accuracy and analysis throughput have been selected as comparison criteria. For ICP-AES measurements, wine samples can be directly analyzed without any sample treatment (i.e. sample dilution or digestion) using pure aqueous standards although internal standardization (IS) (i.e. Sc) is required. The behaviour of the MWDS operating with organic solutions in ICP-MS has been characterized for the first time. In this technique the MWDS has shown its efficiency to mitigate ethanol related matrix effects up to concentrations of 1% (w/w). Therefore, wine samples must be diluted to reduce the ethanol concentration up to this value. The results obtained have shown that the MWDS is a powerful device for the elemental analysis of wine samples in both ICP-AES and ICP-MS. In general, the MWDS has some attractive advantages for elemental wine analysis when compared to a conventional sample introduction system such

  11. Structure of the Aeropyrum pernix L7Ae multifunctional protein and insight into its extreme thermostability

    International Nuclear Information System (INIS)

    Bhuiya, Mohammad Wadud; Suryadi, Jimmy; Zhou, Zholi; Brown, Bernard Andrew II

    2013-01-01

    The crystal structure of A. pernix L7Ae is reported, providing insight into the extreme thermostability of this protein. Archaeal ribosomal protein L7Ae is a multifunctional RNA-binding protein that directs post-transcriptional modification of archaeal RNAs. The L7Ae protein from Aeropyrum pernix (Ap L7Ae), a member of the Crenarchaea, was found to have an extremely high melting temperature (>383 K). The crystal structure of Ap L7Ae has been determined to a resolution of 1.56 Å. The structure of Ap L7Ae was compared with the structures of two homologs: hyperthermophilic Methanocaldococcus jannaschii L7Ae and the mesophilic counterpart mammalian 15.5 kD protein. The primary stabilizing feature in the Ap L7Ae protein appears to be the large number of ion pairs and extensive ion-pair network that connects secondary-structural elements. To our knowledge, Ap L7Ae is among the most thermostable single-domain monomeric proteins presently observed

  12. Plutonium bioassay by inductively coupled plasma mass spectrometry ICP/MS

    International Nuclear Information System (INIS)

    Wyse, E.J.; Fisher, D.R.

    1993-04-01

    The determination of plutonium in urine poses several analytical challenges, e.g., detectability, matrix, etc. We have investigated the feasibility of analyzing plutonium in processed urine by inductively coupled plasma mass spectrometry (ICP/MS). The urine samples are first spiked with 244 Pu as a tracer and internal standard, then processed by co-precipitation and column chromatography using TRU-Spec trademark, an extraction resin. By enhancing ICP/MS detection capabilities via improved sample introduction and data acquisition efficiencies, an instrumental detection limit of 5 to 50 fg (0.3 to 3 fCi for 239 pu) is typically obtained, depending on the desired degree of quantitation. A brief summary of the analytical method as well as the basis for measuring radionuclides by ICP/MS are submitted; the separation procedure, methods of sample introduction, and data acquisition techniques are then highlighted

  13. Dosimetry of 64Cu-DOTA-AE105, a PET tracer for uPAR imaging

    DEFF Research Database (Denmark)

    Persson, Morten; El Ali, Henrik H.; Binderup, Tina

    2014-01-01

    64Cu-DOTA-AE105 is a novel positron emission tomography (PET) tracer specific to the human urokinase-type plasminogen activator receptor (uPAR). In preparation of using this tracer in humans, as a new promising method to distinguish between indolent and aggressive cancers, we have performed PET...... studies in mice to evaluate the in vivo biodistribution and estimate human dosimetry of 64Cu-DOTA-AE105. MethodsFive mice received iv tail injection of 64Cu-DOTA-AE105 and were PET/CT scanned 1, 4.5 and 22h post injection. Volume-of-interest (VOI) were manually drawn on the following organs: heart, lung......Favorable dosimetry estimates together with previously reported uPAR PET data fully support human testing of 64Cu-DOTA-AE105....

  14. Effect of organic matrices on the determination of the trace element chemistry (Mg, Sr, Mg/Ca, Sr/Ca) of aragonitic bivalve shells (Arctica islandica). Comparison of ICP-OES and LA-ICP-MS data

    International Nuclear Information System (INIS)

    Schoene, Bernd R.; Zhang, Zengjie; Jacob, Dorrit; Soldate, Analia; Gillikin, David P.; Tuetken, Thomas; Garbe-Shoenberg, Dieter; McConnaughey, Ted

    2010-01-01

    The element chemistry of biogenic carbonates can provide important data on past environments. However, the Sr/Ca and Mg/Ca ratios as well as the Mg and Sr concentrations of biological carbonates, especially aragonitic bivalves often depart from apparent thermodynamic equilibrium. When measured in situ by means of LA-ICP-MS, the Mg concentration is often substantially enriched (two- to threefold) near the organic-rich, annual growth lines. To test the hypothesis that some organic components exert a major influence on the skeletal metal content, the element chemistry of different shell components (insoluble organic matrix, IOM; dissolved CaCO 3 and soluble organics, SOM) of Arctica islandica was measured by means of ICP-OES and LA-ICP-MS. The ICP-OES data indicate that the IOM is strongly enriched in Mg (130 ppm) and depleted in Sr and Ca (10 ppm and 0.22 wt%, respectively) when compared to the whole biomineral (Mg: 68 to 99 ppm, Sr: 860 to 1,060 ppm, Ca: ∼35.72 wt%). Although the average relative abundance of the IOM barely exceeds 0.46 wt%, its chemical composition in combination with its heterogeneous distribution across the shell can significantly increase estimates of the Mg concentration if measured in situ by LA-ICP-MS. Depending on the distribution of the IOM, the Ca concentration may be significantly lower locally than the average Ca concentration of the whole shell (35.72 wt%). If this remains undetected, the Mg concentration of shell portions with higher than average IOM content is overestimated by LA-ICP-MS and, conversely, the Mg concentration is underestimated in shell portions with lower than average IOM content. Removal of the IOM prior to the chemical analysis by LA-ICP-MS or mathematical correction for the IOM-derived magnesium concentrations is therefore strongly advised. The different chemistry of the IOM may also exert a major control on the trace element to calcium ratios. Shell portions enriched in IOM will show up to 200 times higher Mg

  15. Performance of laser ablation. Quadrupole-based ICP-MS coupling for the analysis of single micrometric uranium particles

    International Nuclear Information System (INIS)

    Fabien Pointurier; Amelie Hubert; Anne-Claire Pottin

    2013-01-01

    In this paper we describe the application of laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) coupling to particle analysis, i.e., the determination of the isotopic composition of micrometric uranium particles. The performances of this analysis technique are compared with those of the two reference particle analysis techniques: secondary ion mass spectrometry (SIMS) and fission track-thermo-ionization mass spectrometry (FT-TIMS), based on the measurement of the isotopic ratios of 235 U/ 238 U in particles present in an inter-comparison particulate sample. The agreement of the results obtained using LA-ICP-MS with target values and with the results obtained using FT-TIMS and SIMS was good. Accuracy was equivalent to that of the other two techniques (±3 % deviation). However, relative experimental uncertainties present with LA-ICP-MS (7 %) were higher than those present with FT-TIMS (4.5 %) and SIMS (3 %). Furthermore, measurement yield of LA-ICP-MS coupling was close to that obtained with the same quadrupole ICP-MS for the measurement of a liquid sample (∼10 -4 ), but lower than that obtained with FT-TIMS and SIMS, respectively, by a factor of 10 and 20, although the particles analyzed using LA-ICP-MS were most likely smaller (diameter ∼0.6 μm, containing 4-7 fg of 235 U). Nevertheless, thanks to the brevity of the signals obtained, the detection capacity for low isotopic concentrations by LA-ICP-MS coupling is equivalent to that of FT-TIMS, although it remains well below that of SIMS (x 15). However, with more sensitive double focusing ICP-MS, performances equivalent to those achieved using SIMS could be obtained. (author)

  16. XPS, AES and laser raman spectroscopy: A fingerprint for a materials surface characterisation

    International Nuclear Information System (INIS)

    Zaidi Embong

    2011-01-01

    This review briefly describes some of the techniques available for analysing surfaces and illustrates their usefulness with a few examples such as a metal and alloy. In particular, Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS) and laser Raman spectroscopy are all described as advanced surface analytical techniques. In analysing a surface, AES and XPS would normally be considered first, with AES being applied where high spatial resolution is required and XPS where chemical state information is needed. Laser Raman spectroscopy is useful for determining molecular bonding. A combination of XPS, AES and Laser Raman spectroscopy can give quantitative analysis from the top few atomic layers with a lateral spatial resolution of < 10 nm. (author)

  17. Analysis of marine samples by neutron-induced prompt gamma-ray technique and ICP-MS

    International Nuclear Information System (INIS)

    Yonezawa, C.; Matsue, H.; McKay, K.; Povinec, P.

    2001-01-01

    Multi-element and isotopic analyses of oils and marine environmental samples were carried out to estimate a contamination source using a 'finger printing' method. Elemental analyses were carried out using neutron-induced prompt gamma-ray analysis (PGA), instrumental neutron activation analysis (INAA) at the Japan Atomic Institute, Tokai-mura, Japan (JAERI) and ICP-MS in the IAEA Marine Environment Laboratory, Monaco (MEL). Fifteen elements including light elements, H, B, N, Si and Ca, which cannot be determined by INAA and ICP-MS, were determined by PGA. A total of 47 elements were determined in the present study. The potential of PGA for the determination of isotopic ratios was tested by measuring 34 S/ 32 S ratios in oils. The evaluation of historical records of marine environmental conditions using annual bands in coral samples was also investigated. (author)

  18. Evolution of microstructure and hardness of AE42 alloy after heat treatments

    DEFF Research Database (Denmark)

    Huang, Y.D.; Dieringa, H.; Hort, N.

    2008-01-01

    properties even further. It is shown that the microstructure of the squeeze-cast AE42 alloy is stable at high temperature 450 degrees C. The subsequent solution and ageing treatments have a limited effect on the hardness. The weak age-hardening is attributed to the precipitation of small amount Of Mg17Al12......The AE42 magnesium alloy was developed for high pressure die casting (HPDC) from low-aluminum magnesium alloys. In this alloy the rare earth (RE) elements were shown to increase creep resistance by forming AlxREy intermetallics along the grain boundaries. The present work investigates...... the microstructure of squeeze cast AE42 magnesium alloy and evaluates its hardness before and after heat treatments. The change in hardness is discussed based on the microstructural observations. Some suggestions are given concerning future design of alloy compositions in order to improve high temperature creep...

  19. Auroral Electrojet Indices Designed to Provide a Global Measure, 2.5-Minute Intervals, of Auroral Zone Magnetic Activity

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Auroral Electrojet index (AE) is designed to provide a global quantitative measure of auroral zone magnetic activity produced by enhanced ionospheric currents...

  20. A comparative study of sample dissolution techniques and plasma-based instruments for the precise and accurate quantification of REEs in mineral matrices

    International Nuclear Information System (INIS)

    Whitty-Léveillé, Laurence; Turgeon, Keven; Bazin, Claude; Larivière, Dominic

    2017-01-01

    The recent commercialisation of inductively coupled plasma tandem mass spectrometric (ICP-MS/MS) instruments has provided analytical chemists with a new tool to properly quantify atomic composition in a variety of matrices with minimal sample preparation. In this article, we report on our assessment of the compatibility of 3 sample preparation techniques (open-vessel acid digestion, microwave digestion and alkaline fusion) for the quantification of rare earth elements (REEs) in mineral matrices. The combination of the high digestion temperatures (1050 °C) and using LiBO_2 as a flux was the most effective strategy for the digestion of all rare earth elements in mineral matrices and was compatible with ICP-MS/MS measurements. We also assessed the analytical performances of ICP-MS/MS against other plasma-based instrumentation (microwave induced plasma and inductively coupled plasma atomic emission spectroscopy (MIP-AES and ICP-AES, respectively) and single quadrupole inductively coupled plasma mass spectrometry (ICP-MS). The comparative study showed that the concentrations obtained by ICP-MS/MS are in excellent agreement with the certified reference material values, and much more suited than the other analytical techniques tested for the quantification of REEs, which exhibited low detectability and/or spectral interferences for some elements/isotopes. Finally, the ruggedness of the analytical protocol proposed which combines a rapid sample dissolution step performed by an automated fusion unit and an ICP-MS/MS as a detector was established using various certified mineral matrices containing variable levels of REEs. - Highlights: • Three types of digestion methods were tested. • Four types of analytical techniques were compared. • Elimination of the spectral interferences encountered in ICP-MS was achieved by the use of Tandem ICP-MS. • Robustness of the analytical procedure was successfully evaluate on four types of certified reference material.

  1. A comparative study of sample dissolution techniques and plasma-based instruments for the precise and accurate quantification of REEs in mineral matrices

    Energy Technology Data Exchange (ETDEWEB)

    Whitty-Léveillé, Laurence; Turgeon, Keven [Département de génie des mines, de la métallurgie et des matériaux, Université Laval, Québec, QC (Canada); Département de chimie, Université Laval, Québec, QC (Canada); Bazin, Claude [Département de génie des mines, de la métallurgie et des matériaux, Université Laval, Québec, QC (Canada); Larivière, Dominic, E-mail: dominic.lariviere@chm.ulaval.ca [Département de chimie, Université Laval, Québec, QC (Canada)

    2017-04-08

    The recent commercialisation of inductively coupled plasma tandem mass spectrometric (ICP-MS/MS) instruments has provided analytical chemists with a new tool to properly quantify atomic composition in a variety of matrices with minimal sample preparation. In this article, we report on our assessment of the compatibility of 3 sample preparation techniques (open-vessel acid digestion, microwave digestion and alkaline fusion) for the quantification of rare earth elements (REEs) in mineral matrices. The combination of the high digestion temperatures (1050 °C) and using LiBO{sub 2} as a flux was the most effective strategy for the digestion of all rare earth elements in mineral matrices and was compatible with ICP-MS/MS measurements. We also assessed the analytical performances of ICP-MS/MS against other plasma-based instrumentation (microwave induced plasma and inductively coupled plasma atomic emission spectroscopy (MIP-AES and ICP-AES, respectively) and single quadrupole inductively coupled plasma mass spectrometry (ICP-MS). The comparative study showed that the concentrations obtained by ICP-MS/MS are in excellent agreement with the certified reference material values, and much more suited than the other analytical techniques tested for the quantification of REEs, which exhibited low detectability and/or spectral interferences for some elements/isotopes. Finally, the ruggedness of the analytical protocol proposed which combines a rapid sample dissolution step performed by an automated fusion unit and an ICP-MS/MS as a detector was established using various certified mineral matrices containing variable levels of REEs. - Highlights: • Three types of digestion methods were tested. • Four types of analytical techniques were compared. • Elimination of the spectral interferences encountered in ICP-MS was achieved by the use of Tandem ICP-MS. • Robustness of the analytical procedure was successfully evaluate on four types of certified reference material.

  2. Production of Mucosally Transmissible SHIV Challenge Stocks from HIV-1 Circulating Recombinant Form 01_AE env Sequences.

    Directory of Open Access Journals (Sweden)

    Lawrence J Tartaglia

    2016-02-01

    Full Text Available Simian-human immunodeficiency virus (SHIV challenge stocks are critical for preclinical testing of vaccines, antibodies, and other interventions aimed to prevent HIV-1. A major unmet need for the field has been the lack of a SHIV challenge stock expressing circulating recombinant form 01_AE (CRF01_AE env sequences. We therefore sought to develop mucosally transmissible SHIV challenge stocks containing HIV-1 CRF01_AE env derived from acutely HIV-1 infected individuals from Thailand. SHIV-AE6, SHIV-AE6RM, and SHIV-AE16 contained env sequences that were >99% identical to the original HIV-1 isolate and did not require in vivo passaging. These viruses exhibited CCR5 tropism and displayed a tier 2 neutralization phenotype. These challenge stocks efficiently infected rhesus monkeys by the intrarectal route, replicated to high levels during acute infection, and established chronic viremia in a subset of animals. SHIV-AE16 was titrated for use in single, high dose as well as repetitive, low dose intrarectal challenge studies. These SHIV challenge stocks should facilitate the preclinical evaluation of vaccines, monoclonal antibodies, and other interventions targeted at preventing HIV-1 CRF01_AE infection.

  3. Early Implementation of THAM for ICP Control: Therapeutic Hypothermia Avoidance and Reduction in Hypertonics/Hyperosmotics

    Directory of Open Access Journals (Sweden)

    F. A. Zeiler

    2014-01-01

    Full Text Available Background. Tromethamine (THAM has been demonstrated to reduce intracranial pressure (ICP. Early consideration for THAM may reduce the need for other measures for ICP control. Objective. To describe 4 cases of early THAM therapy for ICP control and highlight the potential to avoid TH and paralytics and achieve reduction in sedation and hypertonic/hyperosmotic agent requirements. Methods. We reviewed the charts of 4 patients treated with early THAM for ICP control. Results. We identified 2 patients with aneurysmal subarachnoid hemorrhage (SAH and 2 with traumatic brain injury (TBI receiving early THAM for ICP control. The mean time to initiation of THAM therapy was 1.8 days, with a mean duration of 5.3 days. In all patients, after 6 to 12 hours of THAM administration, ICP stability was achieved, with reduction in requirements for hypertonic saline and hyperosmotic agents. There was a relative reduction in mean hourly hypertonic saline requirements of 89.1%, 96.1%, 82.4%, and 97.0% for cases 1, 2, 3, and 4, respectively, comparing pre- to post-THAM administration. Mannitol, therapeutic hypothermia, and paralytics were avoided in all patients. Conclusions. Early administration of THAM for ICP control could potentially lead to the avoidance of other ICP directed therapies. Prospective studies of early THAM administration are warranted.

  4. Multiple Lookup Table-Based AES Encryption Algorithm Implementation

    Science.gov (United States)

    Gong, Jin; Liu, Wenyi; Zhang, Huixin

    Anew AES (Advanced Encryption Standard) encryption algorithm implementation was proposed in this paper. It is based on five lookup tables, which are generated from S-box(the substitution table in AES). The obvious advantages are reducing the code-size, improving the implementation efficiency, and helping new learners to understand the AES encryption algorithm and GF(28) multiplication which are necessary to correctly implement AES[1]. This method can be applied on processors with word length 32 or above, FPGA and others. And correspondingly we can implement it by VHDL, Verilog, VB and other languages.

  5. ICP curve morphology and intracranial flow-volume changes

    DEFF Research Database (Denmark)

    Unnerbäck, Mårten; Ottesen, Johnny T.; Reinstrup, Peter

    2018-01-01

    proposed to shape the ICP curve. This study tested the hypothesis that the ICP curve correlates to intracranial volume changes. METHODS: Cine phase contrast magnetic resonance imaging (MRI) examinations were performed in neuro-intensive care patients with simultaneous ICP monitoring. The MRI was set......BACKGROUND: The intracranial pressure (ICP) curve with its different peaks has been extensively studied, but the exact physiological mechanisms behind its morphology are still not fully understood. Both intracranial volume change (ΔICV) and transmission of the arterial blood pressure have been...

  6. On the solar wind - magnetosphere - ionosphere coupling: AMPTE/CCE particle data and the AE indices

    International Nuclear Information System (INIS)

    Daglis, I.A.; Wilken, B.; Sarris, E.T.; Kremser, G.

    1992-01-01

    We present a statistical study of the substorm particle energization in terms of the energy density of the major magnetospheric ions (H + , O + , He ++ , He + ). The correlation between energy density during substorm expansion phase and the auroral indices (AE, AU, Al) is examined and interpreted. Most distinct result is that the ionospheric origin O + energy density correlate remarkable well with the AE index, while the solar wind origin He ++ energy density does not correlate at all with AE. Mixed origin H + and He + ions exhibit an intermediate behavior. Furthermore, the O + energy density correlates very well with the pre-onset AU index level, while there is no correlation with the pre-onset AL index. The results are interpreted as a result of solar wind. The results are interpreted as a result of solar wind - magnetosphere - ionosphere coupling through the internal magnetospheric dynamo: the ionosphere responds to the increased activity of the internal dynamo (which is due to the high solar wind input) and influences substorm dynamics by feeding the near-Earth magnetotail with energetic ionospheric ions during late growth phase and expansion phase

  7. Changes in histopathology and cytokeratin AE1/AE3 expression in skin graft with different time on Indonesian local cats.

    Science.gov (United States)

    Erwin; Etriwati; Gunanti; Handharyani, Ekowati; Noviana, Deni

    2017-06-01

    A good skin graft histopathology is followed by formation of hair follicle, sweat gland, sebaceous gland, blood vessel, lightly dense connective tissue, epidermis, and dermis layer. This research aimed to observe histopathology feature and cytokeratin AE1/AE3 expression on cat skin post skin grafting within a different period of time. Nine male Indonesian local cats aged 1-2 years old weighing 3-4 kg were separated into three groups. First surgery created defect wound of 2 cm × 2 cm in size to whole groups. The wounds were left alone for several days, differing in interval between each group, respectively: Group I (for 2 days), Group II (for 4 days), and Group III (for 6 days). The second surgery was done to each group which harvested skin of thoracic area and applied it on recipient wound bed. On day 24 th post skin graft was an examination of histopathology and cytokeratin AE1/AE3 immunohistochemistry. Group I donor skin's epidermis layer had not formed completely whereas epidermis of donor skin of Groups II and III had completely formed. In all group hair follicle, sweat gland, sebaceous gland, and neovascularization were found. The density of connective tissue in Group I was very solid than other groups. Cytokeratin AE1/AE3 expression was found on donor skin's epithelial cell in epidermis and dermis layer with very brown intensity for Group II, brown intensity for Group II, and lightly brown for Group I. Histopathological structure and cytokeratin AE1/AE3 expression post skin graft are better in Groups II and III compared to Group I.

  8. Theoretical characterization of quaternary iridium based hydrides NaAeIrH{sub 6} (Ae = Ca, Ba and Sr)

    Energy Technology Data Exchange (ETDEWEB)

    Bouras, S. [Laboratory of Studies Surfaces and Interfaces of Solids Materials, Department of Physics, Faculty of Science, University of Setif 1, 19000 (Algeria); Ghebouli, B., E-mail: bghebouli@yahoo.fr [Laboratory of Studies Surfaces and Interfaces of Solids Materials, Department of Physics, Faculty of Science, University of Setif 1, 19000 (Algeria); Benkerri, M. [Laboratory of Studies Surfaces and Interfaces of Solids Materials, Department of Physics, Faculty of Science, University of Setif 1, 19000 (Algeria); Ghebouli, M.A., E-mail: med.amineghebouli@yahoo.fr [Microelectronic Laboratory (LMSE), University of Bachir Ibrahimi, Bordj-Bou-Arreridj 34000 (Algeria); Research Unit on Emerging Materials (RUEM), University of Setif 1, 19000 (Algeria); Choutri, H. [Microelectronic Laboratory (LMSE), University of Bachir Ibrahimi, Bordj-Bou-Arreridj 34000 (Algeria); Louail, L.; Chihi, T.; Fatmi, M. [Research Unit on Emerging Materials (RUEM), University of Setif 1, 19000 (Algeria); Bouhemadou, A. [Laboratory for Developing New Materials and Their Characterization, Department of Physics, Faculty of Science, University of Setif 1, 19000 (Algeria); Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451 (Saudi Arabia); Khenata, R.; Khachai, H. [Laboratoire de Physique Quantique et de Modélisation Mathématique, Université de Mascara, 29000 (Algeria)

    2015-01-15

    The quaternary iridium based hydrides NaAeIrH{sub 6} (Ae = Ca, Ba and Sr) are promising candidates as hydrogen storage materials. We have studied the structural, elastic, electronic, optical and thermodynamic properties of NaAeIrH{sub 6} (Ae = Ca, Ba and Sr) within the generalized gradient approximation, the local density approximation (LDA) and mBj in the frame of density functional perturbation theory. These alloys have a large indirect Γ–X band gap. The thermodynamic functions were computed using the phonon density of states. The origin of the possible transitions from valence band to conduction band was illustrated. By using the complex dielectric function, the optical properties such as absorption, reflectivity, loss function, refractive index and optical conductivity have been obtained. - Graphical abstract: Real and imaginary parts of the dielectric function, the absorption spectrum α(ω), reflectivity R(ω) and energy-loss spectrum L(ω). - Highlights: • NaAeIrH{sub 6} (Ae = Ca, Ba and Sr) alloys have been investigated. • The elastic moduli, energy gaps are predicted. • The optical and thermal properties were studied.

  9. Dynamic AES – Extending the Lifetime?

    DEFF Research Database (Denmark)

    Tange, Henrik; Andersen, Birger

    2014-01-01

    proven that AES is vulnerable to side-channelattacks, related sub-key attacks and biclicque attacks. This paper introducesa new dynamic version of AES where the main flow is depending on theTNAF (τ -adic Non-Adjacent Form) value. This new approach can preventside-channel attacks, related sub-key attacks...... and biclique attacks....

  10. A Study on AE Signal Analysis of Composite Materials Using Matrix Piezo Electric Sensor

    International Nuclear Information System (INIS)

    Yu, Yeun Ho; Choi, Jin Ho; Kweon, Jin Hwe

    2007-01-01

    As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the study on non-destructive testing methods has become an important research area for improving their reliability and safety. AE (acoustic emission) can evaluate the defects by detecting the emitting strain energy when elastic waves are generated by the initiation and growth of crack, plastic deformation, fiber breakage, matrix cleavage, or delamination. In the paper, AE signals generated under uniaxial tension were measured and analyzed using the 8x8 matrix piezo electric sensor. The electronic circuit to control the transmitting distance of AE signals was designed and constructed. The optical data storage system was also designed to store the AE signal of 64 channels using LED (light emitting diode) elements. From the tests, it was shown that the source location and propagation path of AE signals in composite materials could be detected effectively by the 8x8 matrix piezo electric sensor

  11. Identification of a divalent metal cation binding site in herpes simplex virus 1 (HSV-1) ICP8 required for HSV replication.

    Science.gov (United States)

    Bryant, Kevin F; Yan, Zhipeng; Dreyfus, David H; Knipe, David M

    2012-06-01

    Herpes simplex virus 1 (HSV-1) ICP8 is a single-stranded DNA-binding protein that is necessary for viral DNA replication and exhibits recombinase activity in vitro. Alignment of the HSV-1 ICP8 amino acid sequence with ICP8 homologs from other herpesviruses revealed conserved aspartic acid (D) and glutamic acid (E) residues. Amino acid residue D1087 was conserved in every ICP8 homolog analyzed, indicating that it is likely critical for ICP8 function. We took a genetic approach to investigate the functions of the conserved ICP8 D and E residues in HSV-1 replication. The E1086A D1087A mutant form of ICP8 failed to support the replication of an ICP8 mutant virus in a complementation assay. E1086A D1087A mutant ICP8 bound DNA, albeit with reduced affinity, demonstrating that the protein is not globally misfolded. This mutant form of ICP8 was also recognized by a conformation-specific antibody, further indicating that its overall structure was intact. A recombinant virus expressing E1086A D1087A mutant ICP8 was defective in viral replication, viral DNA synthesis, and late gene expression in Vero cells. A class of enzymes called DDE recombinases utilize conserved D and E residues to coordinate divalent metal cations in their active sites. We investigated whether the conserved D and E residues in ICP8 were also required for binding metal cations and found that the E1086A D1087A mutant form of ICP8 exhibited altered divalent metal binding in an in vitro iron-induced cleavage assay. These results identify a novel divalent metal cation-binding site in ICP8 that is required for ICP8 functions during viral replication.

  12. Concerns about Quadrupole ICP-MS Lead Isotopic Data and Interpretations in the Environment and Health Fields

    Directory of Open Access Journals (Sweden)

    Brian Gulson

    2018-04-01

    Full Text Available There has been a massive increase in recent years of the use of lead (Pb isotopes in attempts to better understand sources and pathways of Pb in the environment and in man or experimental animals. Unfortunately, there have been many cases where the quality of the isotopic data, especially that obtained by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS, are questionable, resulting in questionable identification of potential sources, which, in turn, impacts study interpretation and conclusions. We present several cases where the isotopic data have compromised interpretation because of the use of only the major isotopes 208Pb/206Pb and 207Pb/206Pb, or their graphing in other combinations. We also present some examples comparing high precision data from thermal ionization (TIMS or multi-collector plasma mass spectrometry (MC-ICP-MS to illustrate the deficiency in the Q-ICP-MS data. In addition, we present cases where Pb isotopic ratios measured on Q-ICP-MS are virtually impossible for terrestrial samples. We also evaluate the Pb isotopic data for rat studies, which had concluded that Pb isotopic fractionation occurs between different organs and suggest that this notion of biological fractionation of Pb as an explanation for isotopic differences is not valid. Overall, the brief review of these case studies shows that Q-ICP-MS as commonly practiced is not a suitable technique for precise and accurate Pb isotopic analysis in the environment and health fields.

  13. Concerns about Quadrupole ICP-MS Lead Isotopic Data and Interpretations in the Environment and Health Fields.

    Science.gov (United States)

    Gulson, Brian; Kamenov, George D; Manton, William; Rabinowitz, Michael

    2018-04-11

    There has been a massive increase in recent years of the use of lead (Pb) isotopes in attempts to better understand sources and pathways of Pb in the environment and in man or experimental animals. Unfortunately, there have been many cases where the quality of the isotopic data, especially that obtained by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS), are questionable, resulting in questionable identification of potential sources, which, in turn, impacts study interpretation and conclusions. We present several cases where the isotopic data have compromised interpretation because of the use of only the major isotopes 208 Pb/ 206 Pb and 207 Pb/ 206 Pb, or their graphing in other combinations. We also present some examples comparing high precision data from thermal ionization (TIMS) or multi-collector plasma mass spectrometry (MC-ICP-MS) to illustrate the deficiency in the Q-ICP-MS data. In addition, we present cases where Pb isotopic ratios measured on Q-ICP-MS are virtually impossible for terrestrial samples. We also evaluate the Pb isotopic data for rat studies, which had concluded that Pb isotopic fractionation occurs between different organs and suggest that this notion of biological fractionation of Pb as an explanation for isotopic differences is not valid. Overall, the brief review of these case studies shows that Q-ICP-MS as commonly practiced is not a suitable technique for precise and accurate Pb isotopic analysis in the environment and health fields.

  14. High-resolution line-scan analysis of resin-embedded sediments using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS)

    NARCIS (Netherlands)

    Hennekam, R.; Jilbert, T.; de Lange, G.J.; Reichart, G.J.

    2015-01-01

    Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) line-scanning is a promising technique for producing high-resolution (µm-scale) geochemical records on resin-embedded sediments. However, this approach has not yet been thoroughly tested on sediment samples of known elemental

  15. Identification of TRIM27 as a novel degradation target of herpes simplex virus 1 ICP0.

    Science.gov (United States)

    Conwell, Sara E; White, Anne E; Harper, J Wade; Knipe, David M

    2015-01-01

    The herpes simplex virus 1 (HSV-1) immediate early protein ICP0 performs many functions during infection, including transactivation of viral gene expression, suppression of innate immune responses, and modification and eviction of histones from viral chromatin. Although these functions of ICP0 have been characterized, the detailed mechanisms underlying ICP0's complex role during infection warrant further investigation. We thus undertook an unbiased proteomic approach to identifying viral and cellular proteins that interact with ICP0 in the infected cell. Cellular candidates resulting from our analysis included the ubiquitin-specific protease USP7, the transcriptional repressor TRIM27, DNA repair proteins NBN and MRE11A, regulators of apoptosis, including BIRC6, and the proteasome. We also identified two HSV-1 early proteins involved in nucleotide metabolism, UL39 and UL50, as novel candidate interactors of ICP0. Because TRIM27 was the most statistically significant cellular candidate, we investigated the relationship between TRIM27 and ICP0. We observed rapid, ICP0-dependent loss of TRIM27 during HSV-1 infection. TRIM27 protein levels were restored by disrupting the RING domain of ICP0 or by inhibiting the proteasome, arguing that TRIM27 is a novel degradation target of ICP0. A mutant ICP0 lacking E3 ligase activity interacted with endogenous TRIM27 during infection as demonstrated by reciprocal coimmunoprecipitation and supported by immunofluorescence data. Surprisingly, ICP0-null mutant virus yields decreased upon TRIM27 depletion, arguing that TRIM27 has a positive effect on infection despite being targeted for degradation. These results illustrate a complex interaction between TRIM27 and viral infection with potential positive or negative effects of TRIM27 on HSV under different infection conditions. During productive infection, a virus must simultaneously redirect multiple cellular pathways to replicate itself while evading detection by the host's defenses. To

  16. Dosimetry of 64Cu-DOTA-AE105, a PET tracer for uPAR imaging

    International Nuclear Information System (INIS)

    Persson, Morten; El Ali, Henrik H.; Binderup, Tina; Pfeifer, Andreas; Madsen, Jacob; Rasmussen, Palle; Kjaer, Andreas

    2014-01-01

    64 Cu-DOTA-AE105 is a novel positron emission tomography (PET) tracer specific to the human urokinase-type plasminogen activator receptor (uPAR). In preparation of using this tracer in humans, as a new promising method to distinguish between indolent and aggressive cancers, we have performed PET studies in mice to evaluate the in vivo biodistribution and estimate human dosimetry of 64 Cu-DOTA-AE105. Methods: Five mice received iv tail injection of 64 Cu-DOTA-AE105 and were PET/CT scanned 1, 4.5 and 22 h post injection. Volume-of-interest (VOI) were manually drawn on the following organs: heart, lung, liver, kidney, spleen, intestine, muscle, bone and bladder. The activity concentrations in the mentioned organs [%ID/g] were used for the dosimetry calculation. The %ID/g of each organ at 1, 4.5 and 22 h was scaled to human value based on a difference between organ and body weights. The scaled values were then exported to OLINDA software for computation of the human absorbed doses. The residence times as well as effective dose equivalent for male and female could be obtained for each organ. To validate this approach, of human projection using mouse data, five mice received iv tail injection of another 64 Cu-DOTA peptide-based tracer, 64 Cu-DOTA-TATE, and underwent same procedure as just described. The human dosimetry estimates were then compared with observed human dosimetry estimate recently found in a first-in-man study using 64 Cu-DOTA-TATE. Results: Human estimates of 64 Cu-DOTA-AE105 revealed the heart wall to receive the highest dose (0.0918 mSv/MBq) followed by the liver (0.0815 mSv/MBq), All other organs/tissue were estimated to receive doses in the range of 0.02–0.04 mSv/MBq. The mean effective whole-body dose of 64 Cu-DOTA-AE105 was estimated to be 0.0317 mSv/MBq. Relatively good correlation between human predicted and observed dosimetry estimates for 64 Cu-DOTA-TATE was found. Importantly, the effective whole body dose was predicted with very high

  17. Dosimetry of 64Cu-DOTA-AE105, a PET tracer for uPAR imaging.

    Science.gov (United States)

    Persson, Morten; El Ali, Henrik H; Binderup, Tina; Pfeifer, Andreas; Madsen, Jacob; Rasmussen, Palle; Kjaer, Andreas

    2014-03-01

    (64)Cu-DOTA-AE105 is a novel positron emission tomography (PET) tracer specific to the human urokinase-type plasminogen activator receptor (uPAR). In preparation of using this tracer in humans, as a new promising method to distinguish between indolent and aggressive cancers, we have performed PET studies in mice to evaluate the in vivo biodistribution and estimate human dosimetry of (64)Cu-DOTA-AE105. Five mice received iv tail injection of (64)Cu-DOTA-AE105 and were PET/CT scanned 1, 4.5 and 22 h post injection. Volume-of-interest (VOI) were manually drawn on the following organs: heart, lung, liver, kidney, spleen, intestine, muscle, bone and bladder. The activity concentrations in the mentioned organs [%ID/g] were used for the dosimetry calculation. The %ID/g of each organ at 1, 4.5 and 22 h was scaled to human value based on a difference between organ and body weights. The scaled values were then exported to OLINDA software for computation of the human absorbed doses. The residence times as well as effective dose equivalent for male and female could be obtained for each organ. To validate this approach, of human projection using mouse data, five mice received iv tail injection of another (64)Cu-DOTA peptide-based tracer, (64)Cu-DOTA-TATE, and underwent same procedure as just described. The human dosimetry estimates were then compared with observed human dosimetry estimate recently found in a first-in-man study using (64)Cu-DOTA-TATE. Human estimates of (64)Cu-DOTA-AE105 revealed the heart wall to receive the highest dose (0.0918 mSv/MBq) followed by the liver (0.0815 mSv/MBq), All other organs/tissue were estimated to receive doses in the range of 0.02-0.04 mSv/MBq. The mean effective whole-body dose of (64)Cu-DOTA-AE105 was estimated to be 0.0317 mSv/MBq. Relatively good correlation between human predicted and observed dosimetry estimates for (64)Cu-DOTA-TATE was found. Importantly, the effective whole body dose was predicted with very high precision

  18. Accurate determination of trace amounts of phosphorus in geological samples by inductively coupled plasma atomic emission spectrometry with ion-exchange separation

    International Nuclear Information System (INIS)

    Asoh, Kazuya; Ebihara, Mitsuru

    2013-01-01

    Graphical abstract: -- Highlights: •We set up an effective ICP-AES procedure for determining trace P in rock samples. •Some certified values of P for reference rock samples were proved to be doubtful. •Accurate and reliable data were presented for a suite of geological reference rocks. -- Abstract: In order to determine trace amounts of phosphorus in geological and cosmochemical rock samples, simple as well as reliable analytical schemes using an ICP-AES instrument were investigated. A (conventional) ICP-AES procedure could determine phosphorus contents at the level of several 100 μg g −1 with a reasonable reproducibility ( −1 ; 1σ). An ICP-AES procedure coupled with matrix-separation using cation and anion exchange resins could lower the quantification level down to 1 μg g −1 or even lower under the present experimental conditions. The matrix-separation ICP-AES procedure developed in this study was applied to twenty-one geological reference samples issued by Geological Survey of Japan. Obtained values vary from 1250 μg g −1 for JB-3 (basalt) to 2.07 μg g −1 for JCt-1 (carbonate). Matrix-separation ICP-AES yielded reasonable reproducibility (less than 8.3%; 1σ) of three replicate analyses for all the samples analyzed. In comparison of our data with certificate values as well as literature or reported values, there appear to be an apparent (and large) discrepancy between our values and certificate/reported values regardless of phosphorus contents. Based on the reproducibility of our data and the analytical capability of the matrix-separation ICP-AES procedure developed in this study (in terms of quantification limit, recovery, selectivity of an analyte through pre-concentration process, etc.), it is concluded that certified values for several reference standard rocks should be reevaluated and revised accordingly. It may be further pointed that some phosphorus data reported in literatures should be critically evaluated when they are to be

  19. High-resolution line-scan analysis of resin-embedded sediments using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS)

    NARCIS (Netherlands)

    Hennekam, Rick; Jilbert, Tom; Mason, Paul R D; de Lange, Gert J.; Reichart, Gert Jan

    2015-01-01

    Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) line-scanning is a promising technique for producing high-resolution (μm-scale) geochemical records on resin-embedded sediments. However, this approach has not yet been thoroughly tested on sediment samples of known elemental

  20. Fabrication of ultrafine manganese oxide-decorated carbon nanofibers for high-performance electrochemical capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ying; Lee, Sungsik; Brown, Dennis E.; Zhao, Hairui; Li, Xinsong; Jiang, Daqiang; Hao, Shijie; Zhao, Yongxiang; Cong, Daoyong; Zhang, Xin; Ren, Yang

    2016-09-01

    Ultrafine manganese oxide-decorated carbon nanofibers (MnOn-CNF) as a new type of electrode materials are facilely fabricated by direct conversion of Mn, Zn-trimesic acid (H3BTC) metal organic framework fibers (Mn-ZnBTC). The construction and evolution of Mn-ZnBTC precursors are investigated by SEM and in situ high-energy XRD. The manganese oxides are highly dispersed onto the porous carbon nanofibers formed simultaneously, verified by TEM, X-ray absorption fine structure (XAFS), Raman, ICP-AES and N2 adsorption techniques. As expected, the resulting MnOn-CNF composites are highly stable, and can be cycled up to 5000 times with a high capacitance retention ratio of 98% in electrochemical capacitor measurements. They show a high capacitance of up to 179 F g–1 per mass of the composite electrode, and a remarkable capacitance of up to 18290 F g–1 per active mass of the manganese(IV) oxide, significantly exceeding the theoretical specific capacitance of manganese(IV) oxide (1370 F g–1). The maximum energy density is up to 19.7 Wh kg–1 at the current density of 0.25 A g–1, even orders higher than those of reported electric double-layer capacitors and pseudocapacitors. The excellent capacitive performance can be ascribed to the joint effect of easy accessibility, high porosity, tight contact and superior conductivity integrated in final MnOn-CNF composites.

  1. The use of MP-AES for determination of plant available P in soil by DL method and distribution of soils into P status classes by DL, AL and Mehlich 3 methods.

    Science.gov (United States)

    Toomsoo, Avo; Jürgens, Meit; Kõlli, Raimo; Künnapas, Allan; Albre, Imbi; Tõnutare, Tõnu; Rodima, Ako

    2017-04-01

    Only small percentage of soil total phosphorus is easily exchangeable between solid and solution phase. Plants are able to assimilate P from environment only in the form of orthophosphate ions (H2PO4- and HPO42-) from soil solution. Deficit of P in soil solution prevents plant normal growth and decreases yield quantity and quality. The excess of P in soil solution causes the pollution of environment and eutrophication of water bodies. Therefore it is important to give to the plant producers the correct fertilization recommendations. Lot of analytical methods are developed for the determination of plant available P in soils. In the Baltic Sea region seven different soils' P analysis methods in use. Each method has its own gradation and often there is more than one gradation for the same method depending from agroecological conditions. For agricultural soils in Estonia there are soil P status gradations according to Mehlich 3, DL and AL methods. Phosphate content in soil can be determined by molybdate method Vis-spectrometrically. Very often for analysis of soils' P content also ICP-OES, ICP-MS and also MP-AES instrumental methods are used The aim of our work was to investigate the possibility of using MP-AES for determination of plant available P in soil by DL method and also to compare how the analysed soils are distributed to M3, AL and DL fertilizer requirement groups according to the P content.

  2. Fatigue Crack Growth Behavior of and Recognition of AE Signals from Composite Patch-Repaired Aluminum Panel

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Kwon, Oh Yang; Jang, Yong Joon

    2007-01-01

    The fatigue crack growth behavior of a cracked and patch-repaired Ah2024-T3 panel has been monitored by acoustic emission(AE). The overall crack growth rate was reduced The crack propagation into the adjacent hole was also retarded by introducing the patch repair. AE signals due to crack growth after the patch repair and those due to debonding of the plate-patch interface were discriminated by using the principal component analysis. The former showed high center frequency and low amplitude, whereas the latter showed long rise tine, low frequency and high amplitude. This type of AE signal recognition method could be effective for the prediction of fatigue crack growth behavior in the patch-repaired structures with the aid of AE source location

  3. Sulfate and sulfide sulfur isotopes (δ34S and δ33S) measured by solution and laser ablation MC-ICP-MS: An enhanced approach using external correction

    Science.gov (United States)

    Pribil, Michael; Ridley, William I.; Emsbo, Poul

    2015-01-01

    Isotope ratio measurements using a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS) commonly use standard-sample bracketing with a single isotope standard for mass bias correction for elements with narrow-range isotope systems measured by MC-ICP-MS, e.g. Cu, Fe, Zn, and Hg. However, sulfur (S) isotopic composition (δ34S) in nature can range from at least − 40 to + 40‰, potentially exceeding the ability of standard-sample bracketing using a single sulfur isotope standard to accurately correct for mass bias. Isotopic fractionation via solution and laser ablation introduction was determined during sulfate sulfur (Ssulfate) isotope measurements. An external isotope calibration curve was constructed using in-house and National Institute of Standards and Technology (NIST) Ssulfate isotope reference materials (RM) in an attempt to correct for the difference. The ability of external isotope correction for Ssulfate isotope measurements was evaluated by analyzing NIST and United States Geological Survey (USGS) Ssulfate isotope reference materials as unknowns. Differences in δ34Ssulfate between standard-sample bracketing and standard-sample bracketing with external isotope correction for sulfate samples ranged from 0.72‰ to 2.35‰ over a δ34S range of 1.40‰ to 21.17‰. No isotopic differences were observed when analyzing Ssulfide reference materials over a δ34Ssulfide range of − 32.1‰ to 17.3‰ and a δ33S range of − 16.5‰ to 8.9‰ via laser ablation (LA)-MC-ICP-MS. Here, we identify a possible plasma induced fractionation for Ssulfate and describe a new method using external isotope calibration corrections using solution and LA-MC-ICP-MS.

  4. Test and Verification of AES Used for Image Encryption

    Science.gov (United States)

    Zhang, Yong

    2018-03-01

    In this paper, an image encryption program based on AES in cipher block chaining mode was designed with C language. The encryption/decryption speed and security performance of AES based image cryptosystem were tested and used to compare the proposed cryptosystem with some existing image cryptosystems based on chaos. Simulation results show that AES can apply to image encryption, which refutes the widely accepted point of view that AES is not suitable for image encryption. This paper also suggests taking the speed of AES based image encryption as the speed benchmark of image encryption algorithms. And those image encryption algorithms whose speeds are lower than the benchmark should be discarded in practical communications.

  5. Quantification of trace amounts of rare earth elements in high purity gadolinium oxide by sector field inductively coupled plasma mass spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Pedreira, W.R.; Silva Queiroz, C.A. da; Abrao, A.; Pimentel, M.M.

    2004-01-01

    In recent years, rare earth elements (REEs) have received much attention in the fields of geochemistry and industry. Gadolinium oxide is used for many different high technology applications such as infrared absorbing automotive glass, petroleum cracking catalyst, gadolinium-yttrium garnets, microwave applications, and color TV tube phosphors. It can also be used in optical glass manufacturing and in the electronic industry. Rapid and accurate determinations of the rare earth elements are increasingly required as industrial demands expand. In general, the inductively coupled plasma mass spectrometry (ICP-MS) presents some advantages for trace element analysis, due to high sensitivity and resolution, when compared with other analytical techniques. In this work, sector field inductively coupled plasma mass spectrometry was used. Sixteen elements (Sc, Y, and 14 lanthanides) were determined selectively with the ICP-MS system using a concentration gradient method. The detection limits with the ICP-MS system were about 0.2-8 pg ml -1 . The recovery percentage ranged from 95 to 100% for different rare earth elements. The %R.S.D. of the methods varying between 1.5 and 2.5% for a set of five (n=5) replicates was found for the IPEN's material and for the certificate reference sample. Determination of trace REEs in two high pure gadolinium oxides samples (IPEN and JMC) was performed. IPEN's material is highly pure (>99.99%) and was successfully analyzed without spectral interference

  6. A More Compact AES

    Science.gov (United States)

    Canright, David; Osvik, Dag Arne

    We explore ways to reduce the number of bit operations required to implement AES. One way involves optimizing the composite field approach for entire rounds of AES. Another way is integrating the Galois multiplications of MixColumns with the linear transformations of the S-box. Combined with careful optimizations, these reduce the number of bit operations to encrypt one block by 9.0%, compared to earlier work that used the composite field only in the S-box. For decryption, the improvement is 13.5%. This work may be useful both as a starting point for a bit-sliced software implementation, where reducing operations increases speed, and also for hardware with limited resources.

  7. The effect of CFRP on retrofitting of damaged HSRC beams using AE technique

    Science.gov (United States)

    Soffian Noor, M. S.; Noorsuhada, M. N.

    2017-12-01

    This paper presents the effect of carbon fibre reinforced polymer (CFRP) on retrofitted high strength reinforced concrete (HSRC) beams using acoustic emission (AE) technique. Two RC beam parameters were prepared. The first was the control beam which was undamaged HSRC beam. The second was the damaged HSRC beam retrofitted with CFRP on the soffit. The main objective of this study is to assess the crack modes of HSRC beams using AE signal strength. The relationship between signal strength, load and time were analysed and discussed. The crack pattern observed from the visual observation was also investigated. HSRC beam retrofitted with CFRP produced high signal strength compared to control beam. It demonstrates the effect of the AE signal strength for interpretation and prediction of failure modes that might occur in the beam specimens.

  8. Evaluation of the use of envelope analysis and DWT on AE signals generated from degrading shafts

    International Nuclear Information System (INIS)

    Gu, Dongsik; Kim, Jaegu; Kelimu, Tulugan; Huh, Sun-Chul; Choi, Byeong-Keun

    2012-01-01

    Vibration analysis is widely used in machinery diagnosis. Wavelet transforms and envelope analysis, which have been implemented in many applications in the condition monitoring of machinery, are applied in the development of a condition monitoring system for early detection of faults generated in several key components of machinery. Early fault detection is a very important factor in condition monitoring and a basic component for the application of condition-based maintenance (CBM) and predictive maintenance (PM). In addition, acoustic emission (AE) sensors have specific characteristics that are highly sensitive to high-frequency and low-energy signals. Therefore, the AE technique has been applied recently in studies on the early detection of failure. In this paper, AE signals caused by crack growth on a rotating shaft were captured through an AE sensor. The AE signatures were pre-processed using the proposed signal processing method, after which power spectrums were generated from the FFT results. In the power spectrum, some peaks from fault frequencies were presented. According to the results, crack growth in rotating machinery can be considered and detected using an AE sensor and the signal processing method.

  9. Characterization of high level waste for minor actinides by chemical separation and alpha spectrometry

    International Nuclear Information System (INIS)

    Murali, M.S.; Bhattacharayya, A.; Kar, A.S.; Tomar, B.S.; Manchanda, V.K.

    2010-01-01

    Quantification of minor actinides present in of High Level Waste (HLW) solutions originating from the power reactors is important in view of management of radioactive wastes and actinide partitioning. Several methods such as ICP-MS, X-ray fluorescence methods, ICP-AES, alpha spectrometry are used in characterizing such types of wastes. As alpha spectrometry is simple and reliable, this technique has been used for the estimation of minor actinides after devising steps of separation for estimating Np and Pu present in HLW solutions of PHWR origin. Using a wealth of knowledge appropriate to the solution chemistry of actinides, the task of separation, though appears easy, it is challenging job for a radiochemist handling high-dose HLW samples, for obtaining clean alpha peaks for Np and Pu. This paper reports on the successful attempt made to quantify 241 Am, 244 Cm, Pu (239 mainly) and 237 Np present in HLW-PHWR obtained from PREFRE, Tarapur

  10. Application of laser ablation-ICP-MS to determine high-resolution elemental profiles across the Cretaceous/Paleogene boundary at Agost (Spain)

    NARCIS (Netherlands)

    Sosa-Montes de Oca, Claudia; de Lange, Gert J.|info:eu-repo/dai/nl/073930962; Martínez-Ruiz, Francisca; Rodríguez-Tovar, Francisco J.

    2018-01-01

    A high-resolution analysis of the distribution of major and trace elements across a Cretaceous/Paleogene boundary (KPgB) was done using Laser Ablation-Inductivity Coupled Plasma-Mass Spectrometry (LA-ICP-MS) and was compared with traditional distinct sampling and analysis. At the Agost site (SE

  11. Quantitating Iron in Serum Ferritin by Use of ICP-MS

    Science.gov (United States)

    Smith, Scott M.; Gillman, Patricia L.

    2003-01-01

    A laboratory method has been devised to enable measurement of the concentration of iron bound in ferritin from small samples of blood (serum). Derived partly from a prior method that depends on large samples of blood, this method involves the use of an inductively-coupled-plasma mass spectrometer (ICP-MS). Ferritin is a complex of iron with the protein apoferritin. Heretofore, measurements of the concentration of serum ferritin (as distinguished from direct measurements of the concentration of iron in serum ferritin) have been used to assess iron stores in humans. Low levels of serum ferritin could indicate the first stage of iron depletion. High levels of serum ferritin could indicate high levels of iron (for example, in connection with hereditary hemochromatosis an iron-overload illness that is characterized by progressive organ damage and can be fatal). However, the picture is complicated: A high level of serum ferritin could also indicate stress and/or inflammation instead of (or in addition to) iron overload, and low serum iron concentration could indicate inflammation rather than iron deficiency. Only when concentrations of both serum iron and serum ferritin increase and decrease together can the patient s iron status be assessed accurately. Hence, in enabling accurate measurement of the iron content of serum ferritin, the present method can improve the diagnosis of the patient s iron status. The prior method of measuring the concentration of iron involves the use of an atomic-absorption spectrophotometer with a graphite furnace. The present method incorporates a modified version of the sample- preparation process of the prior method. First, ferritin is isolated; more specifically, it is immobilized by immunoprecipitation with rabbit antihuman polyclonal antibody bound to agarose beads. The ferritin is then separated from other iron-containing proteins and free iron by a series of centrifugation and wash steps. Next, the ferritin is digested with nitric acid

  12. AES Modular Power Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — The AES Modular Power Systems (AMPS) project will demonstrate and infuse modular power electronics, batteries, fuel cells, and autonomous control for exploration...

  13. Multi-element analyses of Vietnamese environmental samples for radiation protection

    International Nuclear Information System (INIS)

    Mai, T.H.; Nguyen, T.B.; Nguyen, T.N.; Yoshida, S.

    2005-01-01

    The Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) were used for measuring 8 major and 27 trace elements in food and soil samples collected in Vietnam. The concentration of elements in food samples was different from different locations and also from different food groups. Depth profiles of the elements were discussed for soil samples. (author)

  14. AES/STEM grain boundary analysis of stabilized zirconia ceramics

    NARCIS (Netherlands)

    Winnubst, Aloysius J.A.; Kroot, P.J.M.; Burggraaf, A.J.

    1983-01-01

    Semiquantitative Auger Electron Spectroscopy (AES) on pure monophasic (ZrO2)0.83(YO1.5)0.17 was used to determine the chemical composition of the grain boundaries. Grain boundary enrichment with Y was observed with an enrichment factor of about 1.5. The difference in activation energy of the ionic

  15. Multielemental speciation analysis by advanced hyphenated technique - HPLC/ICP-MS: A review.

    Science.gov (United States)

    Marcinkowska, Monika; Barałkiewicz, Danuta

    2016-12-01

    Speciation analysis has become an invaluable tool in human health risk assessment, environmental monitoring or food quality control. Another step is to develop reliable multielemental speciation methodologies, to reduce costs, waste and time needed for the analysis. Separation and detection of species of several elements in a single analytical run can be accomplished by high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry (HPLC/ICP-MS). Our review assembles articles concerning multielemental speciation determination of: As, Se, Cr, Sb, I, Br, Pb, Hg, V, Mo, Te, Tl, Cd and W in environmental, biological, food and clinical samples analyzed with HPLC/ICP-MS. It addresses the procedures in terms of following issues: sample collection and pretreatment, selection of optimal conditions for elements species separation by HPLC and determination using ICP-MS as well as metrological approach. The presented work is the first review article concerning multielemental speciation analysis by advanced hyphenated technique HPLC/ICP-MS. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Investigation of anodic TiO2 nanotube composition with high spatial resolution AES and ToF SIMS

    Science.gov (United States)

    Dronov, Alexey; Gavrilin, Ilya; Kirilenko, Elena; Dronova, Daria; Gavrilov, Sergey

    2018-03-01

    High resolution Scanning Auger Electron Spectroscopy (AES) and Time-of-Flight Secondary Ion Mass-Spectrometry (ToF SIMS) were used to investigate structure and elemental composition variation of both across an array of TiO2 nanotubes (NTs) and single tube of an array. The TiO2 NT array was grown by anodic oxidation of Ti foil in fluorine-containing ethylene glycol electrolyte. It was found that the studied anodic TiO2 nanotubes have a layered structure with rather sharp interfaces. The differences in AES depth profiling results of a single tube with the focused primary electron beam (point analysis) and over an area of 75 μm in diameter of a nanotube array with the defocused primary electron beam are discussed. Depth profiling by ToF SIMS was carried out over approximately the same size of a nanotube array to determine possible ionic fragments in the structure. The analysis results show that the combination of both mentioned methods is useful for a detailed analysis of nanostructures with complex morphology and multi-layered nature.

  17. Analytical developments in ICP-MS for arsenic and selenium speciation. Application to granitic waters

    International Nuclear Information System (INIS)

    Garraud, Herve

    1999-01-01

    Nuclear waste storage in geological areas needs the understanding of the physico-chemistry of groundwaters interactions with surrounding rocks. Redox potential measurements and speciation, calculated from geochemical modelling are not significant for the determination of water reactivity. We have thus chosen to carry out experimental speciation by developing sensitive analytical tools with respect of specie chemical identity. We have studied two redox indicators from reference sites (thermal waters from Pyrenees, France): arsenic and selenium. At first, we have determined the concentrations in major ions (sulphide, sulphate, chloride, fluoride, carbonate, Na, K, Ca). Speciation was conducted by HPLC hyphenated to quadrupole ICP-MS and high resolution ICP-MS. These analyses have shown the presence of two new arsenic species in solution, in addition of a great reactivity of these waters during stability studies. A sampling, storage and analysis method is described. (author) [fr

  18. Analysis of ZDDP Content and Thermal Decomposition in Motor Oils Using NAA and NMR

    Science.gov (United States)

    Ferguson, S.; Johnson, J.; Gonzales, D.; Hobbs, C.; Allen, C.; Williams, S.

    Zinc dialkyldithiophosphates (ZDDPs) are one of the most common anti-wear additives present in commercially-available motor oils. The ZDDP concentrations of motor oils are most commonly determined using inductively coupled plasma atomic emission spectroscopy (ICP-AES). As part of an undergraduate research project, we have determined the Zn concentrations of eight commercially-available motor oils and one oil additive using neutron activation analysis (NAA), which has potential for greater accuracy and less sensitivity to matrix effects as compared to ICP-AES. The 31P nuclear magnetic resonance (31P-NMR) spectra were also obtained for several oil additive samples which have been heated to various temperatures in order to study the thermal decomposition of ZDDPs.

  19. Hypolipidemic effects of starch and γ-oryzanol from wx/ae double-mutant rice on BALB/c.KOR-Apoe(shl) mice.

    Science.gov (United States)

    Nakaya, Makoto; Shojo, Aiko; Hirai, Hiroaki; Matsumoto, Kenji; Kitamura, Shinichi

    2013-01-01

    waxy/amylose-extender (wx/ae) double-mutant japonica rice (Oryza sativa L.) produces resistant starch (RS) and a large amount of γ-oryzanol. Our previous study has shown the hypolipidemic effect of wx/ae brown rice on mice. To identify the functional constituents of the hypolipidemic activity in wx/ae rice, we prepared pure wx/ae starch and γ-oryzanol from wx/ae rice and investigated their effect on the lipid metabolism in BALB/c.KOR/Stm Slc-Apoe(shl) mice. The mice were fed for 3 weeks a diet containing non-mutant rice starch, non-mutant rice starch plus γ-oryzanol, wx/ae starch, or wx/ae starch plus γ-oryzanol. γ-Oryzanol by itself had no effect on the lipid metabolism, and wx/ae starch prevented an accumulation of triacylglycerol (TAG) in the liver. Interestingly, the combination of wx/ae starch plus γ-oryzanol not only prevented a TAG accumulation in the liver, but also partially suppressed the rise in plasma TAG concentration, indicating that wx/ae starch and γ-oryzanol could have a synergistic effect on the lipid metabolism.

  20. Microwave digestion techniques applied to determination of boron by ICP-AES in BNCT program; Digestion de matrices biologicas asistida por microondas para el analisis espectrometrico de boro en BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Silvia S; Di Santo, Norberto R; Garavaglia, Ricardo N; Pucci, Gladys N; Batistoni, Daniel A [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Quimica; Schwint, Amanda E [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Radiobiologia

    1999-07-01

    Recently, boron neutron capture therapy (BNCT) has merged as an interesting option for the treatment of some kind of tumors where established therapies show no success. A molecular boronated species, enriched in {sup 10}B is administrated to the subject; it localizes in malignant tissues depending the kind of tumor and localization. Therefore, a very important fact in BNCT research is the detection of boron at trace or ultra trace levels precisely and accurately. This is extremely necessary as boronated species do localize in tumoral tissue and also localize in liver, kidney, spleen, skin, membranes. By this way, before testing a boronated species, it is mandatory to determine its biodistribution in a statistically meaning population, that is related with managing of a great number of samples. In the other hand, it is necessary to exactly predict when to begin the irradiation and to determine the magnitude of radiation to obtain the desired radiological dose for a specified mean boron concentration. This involves the determination of boron in whole blood, which is related with boron concentration in the tumor object of treatment. The methodology selected for the analysis of boron in whole blood and tissues must join certain characteristics: it must not be dependant of the chemical form of boron, it has to be fast and capable to determine boron accurately and precisely in a wide range of concentrations. The design and validation of experimental models involving animals in BNCT studies and the determination of boron in blood of animals and subjects upon treatment require reliable analytical procedures to determine boron quantitatively in those biologic materials. Inductively coupled plasma-atomic emission spectrometry (ICP-AES) using pneumatic nebulization is one of the most promising methods for boron analysis, but the sample must be liquid and have low solid concentration. In our case, biological tissues and blood, it is mandatory to mineralize and/or dilute

  1. Continuous A.E. monitoring of nuclear systems: some feasibility studies now in-progress in France

    International Nuclear Information System (INIS)

    Roget, J.; Germain, J.L.

    1986-01-01

    Continuous A.E. monitoring of Nuclear systems can give some unique information about abnormal behaviour (leak appearance...) or crack initiation or propagation. Some feasibility studies have been undertaken in France in this field and this paper presents the results we have got in two cases. The study showed that an A.E. surveillance of pressurized safety valves indicates the appearance or the presence of a leak. Functioning noise is not a problem in this case. Secondly a large study have been undertaken to test the resistance of the pipe inner sleeve to thermal fatigue. An A.E. monitoring showed that it is possible to separate A.E. due to Crack extension from other signals by a location method in spite of high noise level. A.E. seems applicable for continuous monitoring. So, complementary tests are in progress to confirm and improve these results

  2. Perceptions, practices and health seeking behaviour constrain JE/AES interventions in high endemic district of North India.

    Science.gov (United States)

    Chaturvedi, Sanjay; Sharma, Neha; Kakkar, Manish

    2017-08-08

    Acute Encephalitis Syndrome (AES) and Japanese Encephalitis (JE) stay as poorly understood phenomena in India. Multiple linkages to determinants such as poverty, socio-economic status, gender, environment, and population distribution, make it a greater developmental issue than just a zoonotic disease. A qualitative study was conducted to map knowledge, perceptions and practices of community and health systems level stakeholders. Seventeen interviews with utilizers of AES care, care givers from human and veterinary sectors, Non-governmental Organizations (NGOs), and pig owners and 4 Focused Group Discussions (FGDs) with farmers, community leaders, and students were conducted in an endemic north Indian district-Kushinagar. Core themes that emerged were: JE/AES been perceived as a deadly disease, but not a major health problem; filthy conditions, filthy water and mosquitoes seen to be associated with JE/AES; pigs not seen as a source of infection; minimal role of government health workers in the first-contact care of acute Illness; no social or cultural resistance to JE vaccination or mosquito control; no gender-based discrimination in the care of acute Illness; and non-utilization of funds available with local self govt. Serious challenges and systematic failures in delivery of care during acute illness, which can critically inform the health systems, were also identified. There is an urgent need for promotive interventions to address lack of awareness about the drivers of JE/AES. Delivery of care during acute illness suffers with formidable challenges and systematic failures. A large portion of mortality can be prevented by early institution of rational management at primary and secondary level, and by avoiding wastage of time and resources for investigations and medications that are not actually required.

  3. 22 CFR 120.30 - The Automated Export System (AES).

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false The Automated Export System (AES). 120.30... DEFINITIONS § 120.30 The Automated Export System (AES). The Automated Export System (AES) is the Department of... system for collection of export data for the Department of State. In accordance with this subchapter U.S...

  4. Simultaneous measurement of {sup 239}Pu, {sup 240}Pu, {sup 241}Pu, and {sup 242}Pu by high resolution inductively coupled plasma mass spectrometer (HR ICP-MS) in marine sediments; Mesure des isotopes du plutonium des sediments marins par spectrometrie de masse a plasma couple inductivement haute resolution (HR ICP-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Bruneau, F

    1999-07-01

    Transuranics elements are of particular interest in radioecological studies because of their radiotoxicity and their potential use to decipher source fingerprints and transport processes. The simultaneous measurement of {sup 239}Pu, {sup 240}Pu, {sup 241}Pu, and {sup 242}Pu in environmental samples requires a specific chemical procedure. This work deals with an analytical procedure which yields a very high grade of purification of Pu suitable for ultra low level detection by HR ICP-MS, from marine sediments. After the elimination of major elements (Fe, Al, Mg...) by a first chromatographic separation, a new device of purification by solvent extraction and concentration by a second chromatographic separation is used to obtain a concentrated and high purified solution of plutonium. The chemical procedure have been validated on IAEA certified sediment samples and on sediment samples collected in the roads of Cherbourg which had been previously analysed by other techniques (a spectrometry and thermo-ionisation mass spectrometer). (author)

  5. Comparison of a neural network with multiple linear regression for quantitative analysis in ICP-atomic emission spectroscopy

    International Nuclear Information System (INIS)

    Schierle, C.; Otto, M.

    1992-01-01

    A two layer perceptron with backpropagation of error is used for quantitative analysis in ICP-AES. The network was trained by emission spectra of two interfering lines of Cd and As and the concentrations of both elements were subsequently estimated from mixture spectra. The spectra of the Cd and As lines were also used to perform multiple linear regression (MLR) via the calculation of the pseudoinverse S + of the sensitivity matrix S. In the present paper it is shown that there exist close relations between the operation of the perceptron and the MLR procedure. These are most clearly apparent in the correlation between the weights of the backpropagation network and the elements of the pseudoinverse. Using MLR, the confidence intervals over the predictions are exploited to correct for the optical device of the wavelength shift. (orig.)

  6. LASER ABLATION-INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY STUDY AT THE 222-S LABORATORY USING HOT-CELL GLOVE BOX PROTOTYPE SYSTEM

    International Nuclear Information System (INIS)

    Seidel, C.M.; Jain, J.; Owens, J.W.

    2009-01-01

    This report describes the installation, testing, and acceptance of the Waste Treatment and Immobilization Plant (WTP) procured laser ablation-inductively coupled plasma-atomic emission spectroscopy (LA-ICP-AES) system for remotely analyzing high-level waste (HLW) samples in a hot cell environment. The work was completed by the Analytical Process Development (APD) group in accordance with Task Order 2005-003; ATS MP 1027, Management Plan for Waste Treatment Plant Project Work Performed by Analytical Technical Services. The APD group at the 222-S Laboratory demonstrated acceptable turnaround time (TAT) and provide sufficient data to assess sensitivity, accuracy, and precision of the LA-ICP-AES method

  7. In vivo evaluation of carborane gadolinium-DTPA complex as an MR imaging boron carrier

    International Nuclear Information System (INIS)

    Nakamura, Hiroyuki; Fukuda, Hiroshi; Girald, F.

    2000-01-01

    The evaluation of the Gd-carborane complex 2 as an MR imaging and boron carrier agent was carried out in vivo using tumor-bearing Donryu rats, MRI, ICP-AES, and α-autoradiography. The MR imaging revealed that the carborane Gd-DTPA 2 was metabolized slower in the body than Gd-DTPA 1. The results of the ICP-AES method indicated that compound 2 was incorporated into normal tissues and metabolized quickly, whereas it was not accumulated into tumor or brain tissue. The α-autoradiography showed that a high level of boron was obtained in the internal organs and in the necrosis of tumor tissue. (author)

  8. In situ quantification of Br and Cl in minerals and fluid inclusions by LA-ICP-MS: a powerful tool to identify fluid sources

    Science.gov (United States)

    Hammerli, Johannes; Rusk, Brian; Spandler, Carl; Emsbo, Poul; Oliver, Nicholas H.S.

    2013-01-01

    Bromine and chlorine are important halogens for fluid source identification in the Earth's crust, but until recently we lacked routine analytical techniques to determine the concentration of these elements in situ on a micrometer scale in minerals and fluid inclusions. In this study, we evaluate the potential of in situ Cl and Br measurements by LA-ICP-MS through analysis of a range of scapolite grains with known Cl and Br concentrations. We assess the effects of varying spot sizes, variable plasma energy and resolve the contribution of polyatomic interferences on Br measurements. Using well-characterised natural scapolite standards, we show that LA-ICP-MS analysis allows measurement of Br and Cl concentrations in scapolite, and fluid inclusions as small as 16 μm in diameter and potentially in sodalite and a variety of other minerals, such as apatite, biotite, and amphibole. As a demonstration of the accuracy and potential of Cl and Br analyses by LA-ICP-MS, we analysed natural fluid inclusions hosted in sphalerite and compared them to crush and leach ion chromatography Cl/Br analyses. Limit of detection for Br is ~8 μg g−1, whereas relatively high Cl concentrations (> 500 μg g−1) are required for quantification by LA-ICP-MS. In general, our LA-ICP-MS fluid inclusion results agree well with ion chromatography (IC) data. Additionally, combined cathodoluminescence and LA-ICP-MS analyses on natural scapolites within a well-studied regional metamorphic suite in South Australia demonstrate that Cl and Br can be quantified with a ~25 μm resolution in natural minerals. This technique can be applied to resolve a range of hydrothermal geology problems, including determining the origins of ore forming brines and ore deposition processes, mapping metamorphic and hydrothermal fluid provinces and pathways, and constraining the effects of fluid–rock reactions and fluid mixing.

  9. References: AePW publications

    Data.gov (United States)

    National Aeronautics and Space Administration — This page is the repository for the publications resulting from the AePW. This includes the special sessions at conferences: AIAA ASM 2012, Grapevine TX; AIAA SDM...

  10. David Price--Pioneer of digital ICP monitoring, neurosurgeon and teacher.

    Science.gov (United States)

    Czosnyka, Marek; Kirollos, Ramez; van Hille, Philip

    2015-06-01

    In early 1970s first personal desk-top computers started to be available in hospitals. Mr Price was one of the pioneers introducing his own software to identify Marmarou's model of CSF space during infusion studies to diagnose patients suffering from hydrocephalus. His closed-loop control system for infusion of mannitol to manage patients at risk of intracranial hypertension was designed in 1977. The system worked successfully for 10 years in Pinderfields Hospital in Wakefield, UK. In the middle 1980's he initiated international cooperation with Children's Health Centre in Poland in long-term computer-assisted monitoring and analysis of ICP. Software designed in a course of this cooperation paved the way for contemporary package of ICM+ (Intensive Care Monitor, University of Cambridge, UK). Our scientific portfolio from these years (1985-1995) contains hundreds of head injured patients with waveform ICP analysis, introduction of compensatory reserve index RAP, few highly cited papers. Now, we understand ICP much better thanks to David's personal passion and extremely friendly support.

  11. Comparative measurements of mineral elements in milk powders with laser-induced breakdown spectroscopy and inductively coupled plasma atomic emission spectroscopy.

    Science.gov (United States)

    Lei, W Q; El Haddad, J; Motto-Ros, V; Gilon-Delepine, N; Stankova, A; Ma, Q L; Bai, X S; Zheng, L J; Zeng, H P; Yu, J

    2011-07-01

    Mineral elements contained in commercially available milk powders, including seven infant formulae and one adult milk, were analyzed with inductively coupled plasma atomic emission spectrometry (ICP-AES) and laser-induced breakdown spectroscopy (LIBS). The purpose of this work was, through a direct comparison of the analytical results, to provide an assessment of the performance of LIBS, and especially of the procedure of calibration-free LIBS (CF-LIBS), to deal with organic compounds such as milk powders. In our experiments, the matrix effect was clearly observed affecting the analytical results each time laser ablation was employed for sampling. Such effect was in addition directly observed by determining the physical parameters of the plasmas induced on the different samples. The CF-LIBS procedure was implemented to deduce the concentrations of Mg and K with Ca as the internal reference element. Quantitative analytical results with CF-LIBS were validated with ICP-AES measurements and nominal concentrations specified for commercial milks. The obtained good results with the CF-LIBS procedure demonstrate its capacity to take into account the difference in physical parameters of the plasma in the calculation of the concentrations of mineral elements, which allows a significant reduction of the matrix effect related to laser ablation. We finally discuss the way to optimize the implementation of the CF-LIBS procedure for the analysis of mineral elements in organic materials.

  12. Ultratrace analysis of {sup 129}I in sediments by ICP-MS with collision cell

    Energy Technology Data Exchange (ETDEWEB)

    Izmer, A.V.; Becker, J.S. [Research Center Juelich (Germany). Central Div. of Analytical Chemistry; Boulyga, S.F. [Mainz Univ. (Germany). Inst. for Inorganic Chemistry and Analytical Chemistry; Zoriy, M.V. [Research Center Juelich (Germany). Central Div. of Analytical Chemistry]|[Research Center Juelich (Germany). Dept. for Safety and Radiation Protection

    2004-07-01

    The aim of the work was the development of a rapid and high-sensitive analytical method using ICP-MS with hexapole collision cell (ICP-CC-MS) for the determination of low 129I+/127I+ isotope ratios in synthetic lab standards and environmental samples. A special direct sample introduction device for iodine extraction via the gas phase from solid environmental material coupled on-line to ICP-CC-QMS was developed. The detection limit for 129I+ determination in aqueous solution and soil samples via gas-phase extraction was determined to be of 0.8 pg/g and 30 pg/g, respectively. (orig.)

  13. Perceptions, practices and health seeking behaviour constrain JE/AES interventions in high endemic district of North India

    Directory of Open Access Journals (Sweden)

    Sanjay Chaturvedi

    2017-08-01

    Full Text Available Abstract Background Acute Encephalitis Syndrome (AES and Japanese Encephalitis (JE stay as poorly understood phenomena in India. Multiple linkages to determinants such as poverty, socio-economic status, gender, environment, and population distribution, make it a greater developmental issue than just a zoonotic disease. Methods A qualitative study was conducted to map knowledge, perceptions and practices of community and health systems level stakeholders. Seventeen interviews with utilizers of AES care, care givers from human and veterinary sectors, Non-governmental Organizations (NGOs, and pig owners and 4 Focused Group Discussions (FGDs with farmers, community leaders, and students were conducted in an endemic north Indian district-Kushinagar. Results Core themes that emerged were: JE/AES been perceived as a deadly disease, but not a major health problem; filthy conditions, filthy water and mosquitoes seen to be associated with JE/AES; pigs not seen as a source of infection; minimal role of government health workers in the first-contact care of acute Illness; no social or cultural resistance to JE vaccination or mosquito control; no gender-based discrimination in the care of acute Illness; and non-utilization of funds available with local self govt. Serious challenges and systematic failures in delivery of care during acute illness, which can critically inform the health systems, were also identified. Conclusion There is an urgent need for promotive interventions to address lack of awareness about the drivers of JE/AES. Delivery of care during acute illness suffers with formidable challenges and systematic failures. A large portion of mortality can be prevented by early institution of rational management at primary and secondary level, and by avoiding wastage of time and resources for investigations and medications that are not actually required.

  14. LA-ICP-MS of magnetite: Methods and reference materials

    Science.gov (United States)

    Nadoll, P.; Koenig, A.E.

    2011-01-01

    Magnetite (Fe3O4) is a common accessory mineral in many geologic settings. Its variable geochemistry makes it a powerful petrogenetic indicator. Electron microprobe (EMPA) analyses are commonly used to examine major and minor element contents in magnetite. Laser ablation ICP-MS (LA-ICP-MS) is applicable to trace element analyses of magnetite but has not been widely employed to examine compositional variations. We tested the applicability of the NIST SRM 610, the USGS GSE-1G, and the NIST SRM 2782 reference materials (RMs) as external standards and developed a reliable method for LA-ICP-MS analysis of magnetite. LA-ICP-MS analyses were carried out on well characterized magnetite samples with a 193 nm, Excimer, ArF LA system. Although matrix-matched RMs are sometimes important for calibration and normalization of LA-ICP-MS data, we demonstrate that glass RMs can produce accurate results for LA-ICP-MS analyses of magnetite. Cross-comparison between the NIST SRM 610 and USGS GSE-1G indicates good agreement for magnetite minor and trace element data calibrated with either of these RMs. Many elements show a sufficiently good match between the LA-ICP-MS and the EMPA data; for example, Ti and V show a close to linear relationship with correlation coefficients, R2 of 0.79 and 0.85 respectively. ?? 2011 The Royal Society of Chemistry.

  15. Fósforo extraído pela solução de Mehlich-1 determinado por colorimetria e ICP em solos do Sul do Brasil Phosphorus extracted with Mehlich-1 determined by colorimetric and ICP methods in South Brazilian soils

    Directory of Open Access Journals (Sweden)

    Leandro Bortolon

    2010-02-01

    Full Text Available A adoção do ICP para análise de fósforo tem apresentado controvérsias, pois o valor determinado por essa técnica, muitas vezes, não é comparável com o obtido por colorimetria. Nos EUA, alguns laboratórios apresentam restrições à adoção dessa técnica, pelas seguintes razões: as recomendações de adubação em uso foram desenvolvidas empregando-se o método colorimétrico para a determinação do P; e as diferenças significativas têm sido obtidas entre os teores determinados por colorimetria e por ICP, pois, devido à alta temperatura do plasma, o ICP mede outras formas de P além do ortofosfato, atribuída ao P orgânico na solução. Este estudo teve por objetivo comparar os teores de P extraído do solo pela solução de Mehlich-1, determinado por colorimetria (COL e por ICP, em 595 amostras de solos do Estado do Rio Grande do Sul, com amplas variações nas características físicas, químicas e mineralógicas. Os teores de P extraído, determinado por ICP e por COL, não diferiram estatisticamente (r = 0,94; p The adoption of ICP technique to determine P in soil testing has been questioned, due the values determined with this technique is not comparable that those determined with colorimetric method. In the USA, some laboratories are restricted to adopt the ICP technique due the follow reasons: the nutrient recommendations to plants were developed for colorimetric method for P determination; significantly differences have been obtained between P determined with colorimetric and ICP techniques, because the high plasma temperature can measure other P forms besides orthophosphate, attributed to organic P in solution. This study compared the P amounts extracted by Mehlich-1 solution and determined by COL and ICP techniques, in 595 soil samples from the state of Rio Grande do Sul (Brazil with s wide range of soil physic, chemistry and mineralogic properties. The P amounts determined by ICP and COL did not differ statistically

  16. "Storms of crustal stress" and AE earthquake precursors

    Directory of Open Access Journals (Sweden)

    G. P. Gregori

    2010-02-01

    Full Text Available Acoustic emission (AE displays violent paroxysms preceding strong earthquakes, observed within some large area (several hundred kilometres wide around the epicentre. We call them "storms of crustal stress" or, briefly "crustal storms". A few case histories are discussed, all dealing with the Italian peninsula, and with the different behaviour shown by the AE records in the Cephalonia island (Greece, which is characterized by a different tectonic setting.

    AE is an effective tool for diagnosing the state of some wide slab of the Earth's crust, and for monitoring its evolution, by means of AE of different frequencies. The same effect ought to be detected being time-delayed, when referring to progressively lower frequencies. This results to be an effective check for validating the physical interpretation.

    Unlike a seismic event, which involves a much limited focal volume and therefore affects a restricted area on the Earth's surface, a "crustal storm" typically involves some large slab of lithosphere and crust. In general, it cannot be easily reckoned to any specific seismic event. An earthquake responds to strictly local rheological features of the crust, which are eventually activated, and become crucial, on the occasion of a "crustal storm". A "crustal storm" lasts typically few years, eventually involving several destructive earthquakes that hit at different times, at different sites, within that given lithospheric slab.

    Concerning the case histories that are here discussed, the lithospheric slab is identified with the Italian peninsula. During 1996–1997 a "crustal storm" was on, maybe elapsing until 2002 (we lack information for the period 1998–2001. Then, a quiet period occurred from 2002 until 26 May 2008, when a new "crustal storm" started, and by the end of 2009 it is still on. During the 1996–1997 "storm" two strong earthquakes occurred (Potenza and

  17. Determination of trace elements in plant samples using XRF, PIXE and ICP-OES techniques

    International Nuclear Information System (INIS)

    Ahmed, Hassan Elzain Hassan

    2014-07-01

    The purpose of this study is to determine trace element concentration (Ca, Cu, Cr, K,Fe, Mn,Sr, and Za) in some sudanese wild plants namely, Ziziphus Abyssinica and Grewia Tenax. X-ray fluorescence ( X RF), particle-induced x-ray emission ( PIXE) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) techniques were used for element determination. A series of plants standard references materials were used to check the reliability of the different employed techniques as well as to estimate possible factors for correcting the concentration of some elements that deviated significantly from their actual concentration. The results showed that, X RF, PIXE and ICP-OES are equally competitive methods for measuring Ca,K, Fe, Sr and Zn elements. Unlikely to ICP-OES seems to be superior techniques tend to be appropriate methods for Cu determination in plant samples however, for Mn element PIXE and ICP-OES are advisable techniques for measuring this element rather than X RF method. On the other hand, ICP-OES seems to be the superior techniques over PIXE and X RF methods for Cr and Ni determination in plant samples. The effect of geographical location on trace elements concentration in plants has been examined through determination of element in different species of Grewia Tenax than collected from different location. Most of measured elements showed similarity indicating there is no significant impact of locations on the difference of element contents. In addition, two plants with different genetic families namely, Ziziphus Spina Christi and Ziziphus Abyssinica were collected from the same location and screened for their trace element content. It was found that there were no difference between the two plants for Ca, K, Cu, Fe, and Sr element. However, significant variations were observed for Mn and Zn concentrations implying the possibility of using of those two elements for plant taxonomy purposes.(Author)

  18. Determination of plutonium in urine samples from 24 h by ICP-W.f.'s and AMS

    International Nuclear Information System (INIS)

    Aragon del Valle, A.; Anton Mateos, M. P.; Chamizo Calvo, E.; Barrado Olmedo, A. I.; Yllera de Llano, A.

    2013-01-01

    The identification and quantification of alpha emitters in biological samples is essential to estimate the internal dose received by workers exposed. The object of this research is to assess the suitability of AMS and ICP-WSFS as measure alternative techniques to the EA of high resolution in the quantification of plutonium in urine 24h. (Author)

  19. A study on the analysis of minerals and materials

    Energy Technology Data Exchange (ETDEWEB)

    Son, Yong O; Lee, Kil Yong; Yoon, Woo Yual; Park, Jin Tai; Yang, Myeong Kwon; Chun, Sang Ki [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    Sample homogeneity is the attribute of a sample that assures the same result will be obtained within measurement uncertainty for all subsamples taken for analysis. Generally, all mineral samples are inhomogeneous to some degree. The fundamental question is whether or not the existing inhomogeneity is detectable under typical measurement conditions. Inhomogeneity varies from one element to another in a given sample, and its detection depends on the analytical sample size and the particle size taken for each measurement. The aim of this study is to measure the homogeneity of the samples and to develop the analytical method of gold and silver in minerals. For these two purposes, three kind of minerals of sulfide, oxide, copper ores which are known to be have gold in them were selected as the target minerals. At first, the sample homogeneity was measured for sample size and its particle size by Fire Assay, NAA, ICP-AES and PIXE. In case of the PIXE, not the elemental content but the relative intensity ratio of emitted x-ray from a pellet({phi}=40 mm, t = 2 mm) was used to measure precisely the sample homogeneity. New analytical methods researched in the study for the precise analysis of gold and silver, ICP-AES, NAA and XRF which are major analysis tool in our group were used. The result was that sample homogeneity increased with increasing the sample size and decreasing the particle size. And trace amount of gold in mineral samples could be analysed accurately by large sample size-short irradiation technique by NAA. ICP-AES was also capable to analysis of ppm grade gold in mineral samples by aqua-regia acid digestion technique. In case of silver, XRF can be used to analysis of tens ppm grade silver but its detection limit was about 10 ppm. ICP-AES can be also used to analysis of silver less than hundreds ppm grade, if the amount of silver over this range, the precipitation of silver chloride formed in the sample solution. So, the analytical methods of silver in

  20. Characterization of Polish rape and honeydew honey according to their mineral contents using ICP-MS and F-AAS/AES

    International Nuclear Information System (INIS)

    Madejczyk, Maria; Baralkiewicz, Danuta

    2008-01-01

    In this work twelve elements (Al, B, Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Ni and Zn) were determined in 30 honey samples from various locations within Poland and in two different types of honey- rape and honeydew. Trace elements (Al, B, Cr, Mn and Ni) were determined by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), however, major elements (Ca, K, Mg, Na) and Cu, Fe, Zn were determined by Flame Atomic Absorption Spectrometry (F-AAS). Cluster analysis of honey data revealed that the origin of honey samples correlated with their chemical composition. It was shown that rape honey includes lower amounts of manganese than honeydew honeys. Also honeydew honey includes much higher concentrations of Al, Cu, K, Fe and Ni in comparison with rape honey. Moreover honeydew honey was found to have a higher mineral content, which reflects sources from which the honey is composed. Trace element analysis showed that the differences in the values found in honey samples could be used as evidence of the quality of honey samples

  1. Clinical epidemiology of human AE in Europe.

    Science.gov (United States)

    Vuitton, D A; Demonmerot, F; Knapp, J; Richou, C; Grenouillet, F; Chauchet, A; Vuitton, L; Bresson-Hadni, S; Millon, L

    2015-10-30

    This review gives a critical update of the situation regarding alveolar echinococcosis (AE) in Europe in humans, based on existing publications and on findings of national and European surveillance systems. All sources point to an increase in human cases of AE in the "historic endemic areas" of Europe, namely Germany, Switzerland, Austria and France and to the emergence of human cases in countries where the disease had never been recognised until the end of the 20th century, especially in central-eastern and Baltic countries. Both increase and emergence could be only due to methodological biases; this point is discussed in the review. One explanation may be given by changes in the animal reservoir of the parasite, Echinococcus multilocularis (increase in the global population of foxes in Europe and its urbanisation, as well as a possible increased involvement of pet animals as definitive infectious hosts). The review also focuses onto 2 more original approaches: (1) how changes in therapeutic attitudes toward malignant and chronic inflammatory diseases may affect the epidemiology of AE in the future in Europe, since a recent survey of such cases in France showed the emergence of AE in patients with immune suppression since the beginning of the 21st century; (2) how setting a network of referral centres in Europe based on common studies on the care management of patients might contribute to a better knowledge of AE epidemiology in the future. Copyright © 2015. Published by Elsevier B.V.

  2. Metabolomic and elemental analysis of camel and bovine urine by GC-MS and ICP-MS.

    Science.gov (United States)

    Ahamad, Syed Rizwan; Alhaider, Abdul Qader; Raish, Mohammad; Shakeel, Faiyaz

    2017-01-01

    Recent studies from the author's laboratory indicated that camel urine possesses antiplatelet activity and anti-cancer activity which is not present in bovine urine. The objective of this study is to compare the volatile and elemental components of bovine and camel urine using GC-MS and ICP-MS analysis. We are interested to know the component that performs these biological activities. The freeze dried urine was dissolved in dichloromethane and then derivatization process followed by using BSTFA for GC-MS analysis. Thirty different compounds were analyzed by the derivatization process in full scan mode. For ICP-MS analysis twenty eight important elements were analyzed in both bovine and camel urine. The results of GC-MS and ICP-MS analysis showed marked difference in the urinary metabolites. GC-MS evaluation of camel urine finds a lot of products of metabolism like benzene propanoic acid derivatives, fatty acid derivatives, amino acid derivatives, sugars, prostaglandins and canavanine. Several research reports reveal the metabolomics studies on camel urine but none of them completely reported the pharmacology related metabolomics. The present data of GC-MS suggest and support the previous studies and activities related to camel urine.

  3. Breaking through the uncertainty ceiling in LA-ICP-MS U-Pb geochronology

    Science.gov (United States)

    Horstwood, M.

    2016-12-01

    Sources of systematic uncertainty associated with session-to-session bias are the dominant contributor to the 2% (2s) uncertainty ceiling that currently limits the accuracy of LA-ICP-MS U-Pb geochronology. Sources include differential downhole fractionation (LIEF), `matrix effects' and ablation volume differences, which result in irreproducibility of the same reference material across sessions. Current mitigation methods include correcting for LIEF mathematically, using matrix-matched reference materials, annealing material to reduce or eliminate radiation damage effects and tuning for robust plasma conditions. Reducing the depth and volume of ablation can also mitigate these problems and should contribute to the reduction of the uncertainty ceiling. Reducing analysed volume leads to increased detection efficiency, reduced matrix-effects, eliminates LIEF, obviates ablation rate differences and reduces the likelihood of intercepting complex growth zones with depth, thereby apparently improving material homogeneity. High detection efficiencies (% level) and low sampling volumes (20um box, 1-2um deep) can now be achieved using MC-ICP-MS such that low volume ablations should be considered part of the toolbox of methods targeted at improving the reproducibility of LA-ICP-MS U-Pb geochronology. In combination with other strategies these improvements should be feasible on any ICP platform. However, reducing the volume of analysis reduces detected counts and requires a change of analytical approach in order to mitigate this. Appropriate strategies may include the use of high efficiency cell and torch technologies and the optimisation of acquisition protocols and data handling techniques such as condensing signal peaks, using log ratios and total signal integration. The tools required to break the 2% (2s) uncertainty ceiling in LA-ICP-MS U-Pb geochronology are likely now known but require a coherent strategy and change of approach to combine their implementation and realise

  4. Quantification and speciation of technetium-99 in samples at low levels: contributions of capillary electrophoresis / ICP-MS system

    International Nuclear Information System (INIS)

    Kasprzak, L.M.

    2007-01-01

    Given the low levels of 99 Tc (long half-lived artificial radionuclide) in the environment (10 -8 M to 10 -12 M), its determination currently necessitates an enrichment and separation from the sample matrix prior to instrumental measurement. Therefore, nuclear safety monitoring requires the knowledge of the redox and chemical properties of this element in order to predict its behaviour and transfer in the environment. So, a separative and very sensitive measurement technique must thus be employed. We have developed a new environmental measurement method applied to the quantification and speciation of 99 Tc in sample at environmental concentrations. Indeed, we have combined a Capillary Electrophoresis (CE) with an Inductively Coupled Plasma Mass Spectrometer (ICP-MS). The limit of detection of 99 Tc is about 2.10 -8 M by CE/ICP-MS system equipped with a PFA-50 nebuliser. In addition to the detection and measurement of technetium, we can separate online 99 Tc(VII) of its interfering radionuclides like molybdenum and ruthenium by CE/ICP-MS. Indeed, due do the different migration time of each anions, it's possible to determinate a signal at m/z= 99 which is only given to 99 Tc. Results obtained by this method have been compared to an usual radiochemical technique, extraction of Tc(VII) by a TEVA resin followed by ICP-MS measurement. Within the framework of storage of spent fuel, studies on the speciation of Tc(VII) by CE / ICP-MS iron-sulphide soils in anoxic conditions have shown that technetium VII is reduced by sulphured suspensions. (author)

  5. Identification of an ICP27-responsive element in the coding region of a herpes simplex virus type 1 late gene.

    Science.gov (United States)

    Sedlackova, Lenka; Perkins, Keith D; Meyer, Julia; Strain, Anna K; Goldman, Oksana; Rice, Stephen A

    2010-03-01

    During productive herpes simplex virus type 1 (HSV-1) infection, a subset of viral delayed-early (DE) and late (L) genes require the immediate-early (IE) protein ICP27 for their expression. However, the cis-acting regulatory sequences in DE and L genes that mediate their specific induction by ICP27 are unknown. One viral L gene that is highly dependent on ICP27 is that encoding glycoprotein C (gC). We previously demonstrated that this gene is posttranscriptionally transactivated by ICP27 in a plasmid cotransfection assay. Based on our past results, we hypothesized that the gC gene possesses a cis-acting inhibitory sequence and that ICP27 overcomes the effects of this sequence to enable efficient gC expression. To test this model, we systematically deleted sequences from the body of the gC gene and tested the resulting constructs for expression. In so doing, we identified a 258-bp "silencing element" (SE) in the 5' portion of the gC coding region. When present, the SE inhibits gC mRNA accumulation from a transiently transfected gC gene, unless ICP27 is present. Moreover, the SE can be transferred to another HSV-1 gene, where it inhibits mRNA accumulation in the absence of ICP27 and confers high-level expression in the presence of ICP27. Thus, for the first time, an ICP27-responsive sequence has been identified in a physiologically relevant ICP27 target gene. To see if the SE functions during viral infection, we engineered HSV-1 recombinants that lack the SE, either in a wild-type (WT) or ICP27-null genetic background. In an ICP27-null background, deletion of the SE led to ICP27-independent expression of the gC gene, demonstrating that the SE functions during viral infection. Surprisingly, the ICP27-independent gC expression seen with the mutant occurred even in the absence of viral DNA synthesis, indicating that the SE helps to regulate the tight DNA replication-dependent expression of gC.

  6. Single-cell analysis by ICP-MS/MS as a fast tool for cellular bioavailability studies of arsenite.

    Science.gov (United States)

    Meyer, S; López-Serrano, A; Mitze, H; Jakubowski, N; Schwerdtle, T

    2018-01-24

    Single-cell inductively coupled plasma mass spectrometry (SC-ICP-MS) has become a powerful and fast tool to evaluate the elemental composition at a single-cell level. In this study, the cellular bioavailability of arsenite (incubation of 25 and 50 μM for 0-48 h) has been successfully assessed by SC-ICP-MS/MS for the first time directly after re-suspending the cells in water. This procedure avoids the normally arising cell membrane permeabilization caused by cell fixation methods (e.g. methanol fixation). The reliability and feasibility of this SC-ICP-MS/MS approach with a limit of detection of 0.35 fg per cell was validated by conventional bulk ICP-MS/MS analysis after cell digestion and parallel measurement of sulfur and phosphorus.

  7. A Novel Detection Platform for Shrimp White Spot Syndrome Virus Using an ICP11-Dependent Immunomagnetic Reduction (IMR) Assay.

    Science.gov (United States)

    Liu, Bing-Hsien; Lin, Yu-Chen; Ho, Chia-Shin; Yang, Che-Chuan; Chang, Yun-Tsui; Chang, Jui-Feng; Li, Chun-Yuan; Cheng, Cheng-Shun; Huang, Jiun-Yan; Lee, Yen-Fu; Hsu, Ming-Hung; Lin, Feng-Chun; Wang, Hao-Ching; Lo, Chu-Fang; Yang, Shieh-Yueh; Wang, Han-Ching

    2015-01-01

    Shrimp white spot disease (WSD), which is caused by white spot syndrome virus (WSSV), is one of the world's most serious shrimp diseases. Our objective in this study was to use an immunomagnetic reduction (IMR) assay to develop a highly sensitive, automatic WSSV detection platform targeted against ICP11 (the most highly expressed WSSV protein). After characterizing the magnetic reagents (Fe3O4 magnetic nanoparticles coated with anti ICP11), the detection limit for ICP11 protein using IMR was approximately 2 x 10(-3) ng/ml, and the linear dynamic range of the assay was 0.1~1 x 10(6) ng/ml. In assays of ICP11 protein in pleopod protein lysates from healthy and WSSV-infected shrimp, IMR signals were successfully detected from shrimp with low WSSV genome copy numbers. We concluded that this IMR assay targeting ICP11 has potential for detecting the WSSV.

  8. Atomic-AES: A compact implementation of the AES encryption/decryption core

    DEFF Research Database (Denmark)

    Banik, Subhadeep; Bogdanov, Andrey; Regazzoni, Francesco

    2016-01-01

    The implementation of the AES encryption core by Moradi et al. at Eurocrypt 2011 is one of the smallest in terms of gate area. The circuit takes around 2400 gates and operates on an 8 bit datapath. However this is an encryption only core and unable to cater to block cipher modes like CBC and ELm...

  9. Reconfigurable Secure Video Codec Based on DWT and AES Processor

    Directory of Open Access Journals (Sweden)

    Rached Tourki

    2010-01-01

    Full Text Available In this paper, we proposed a secure video codec based on the discrete wavelet transformation (DWT and the Advanced Encryption Standard (AES processor. Either, use of video coding with DWT or encryption using AES is well known. However, linking these two designs to achieve secure video coding is leading. The contributions of our work are as follows. First, a new method for image and video compression is proposed. This codec is a synthesis of JPEG and JPEG2000,which is implemented using Huffman coding to the JPEG and DWT to the JPEG2000. Furthermore, an improved motion estimation algorithm is proposed. Second, the encryptiondecryption effects are achieved by the AES processor. AES is aim to encrypt group of LL bands. The prominent feature of this method is an encryption of LL bands by AES-128 (128-bit keys, or AES-192 (192-bit keys, or AES-256 (256-bit keys.Third, we focus on a method that implements partial encryption of LL bands. Our approach provides considerable levels of security (key size, partial encryption, mode encryption, and has very limited adverse impact on the compression efficiency. The proposed codec can provide up to 9 cipher schemes within a reasonable software cost. Latency, correlation, PSNR and compression rate results are analyzed and shown.

  10. Study of HPLC/ICP-MS coupling for the As speciation; Estudo de um acoplamento de HPLC/ICP-MS para a especiacao do As

    Energy Technology Data Exchange (ETDEWEB)

    Cortez, Bruna C.G.; Oliveira, Arno Heeren de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear]. E-mail: brunacortez2004@yahoo.com.br; heeren@nuclear.ufmg.br

    2005-07-01

    Trace metals in the environment may provide benefit or risk to humans, other life forms, and the environment. More robust and information-rich trace and ultra-trace analyses are needed to all adequate risk/benefit assessments. Further, it is no longer adequate to consider only the total trace metal or metalloid, because the impact of elements on ecological systems or biological organisms is not necessarily given by total element concentrations alone. It is necessary to determine the chemical form (species) of the element, primarily the oxidation state or the organometallic nature, because different species of the same metal can range from essential to innocuous to toxic. The actual toxicity levels from different arsenic compounds vary greatly. Inorganic arsenic is considered the most acutely toxic form; arsenite (As{sup III}) is more toxic than arsenate (As{sup V}). The chronic toxicity of arsenic compounds is currently not well understood and is actively being researched. In this study, the viability of the ICP-MS detector coupled with High Performance Liquid Chromatography (HPLC) was tested in 21 water samples from the Das Velhas River, Minas Gerais state, in Brazil. The results showed that the low detection limits and the ease coupling HPLC system - which offers a rugged and versatile separation technique - makes ICP-MS a successful detection method for arsenic speciation analysis. (author)

  11. Mechanical seal monitoring technique by acoustic emission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kataoka, Tadashi; Fujita, Yoshihiro; Kawaguchi, Kazunori; Saito, Kazuhiro; Yokota, Setsuo; Hisada, Yasuhide; Masahiro, Komatsu

    1987-09-20

    This report describes a technique for mechanical seal monitoring through acoustic emission (AE) measurement. The equipment consists of an AE sensor, preamplifier, multiplexer, main amplifier, effective value transducer and computer system. When the sealed liquid pressure undergoes a large change, the seal surface configuration is monitored and evaluated accurately through AE measurement. If the mechanical seal surface id damaged or worn, the AE level is kept high or continues to fluctuate largely for a rather long period. When leak occurs, the AE value shows great fluctuations either at extremely low levels or at high levels. The former trend is considered to result from a decrease in solid contact due to an excessive amount of liquid film being formed at the seal surface during leak. In the latter case, the leak is attributed to severe damage to the seal surface. (18 figs, 1 tab, 5 photos, 3 refs)

  12. Detection of multiple AE signal by triaxial hodogram analysis; Sanjiku hodogram ho ni yoru taju acoustic emission no kenshutsu

    Energy Technology Data Exchange (ETDEWEB)

    Nagano, K; Yamashita, T [Muroran Institute of Technology, Hokkaido (Japan)

    1997-05-27

    In order to evaluate dynamic behavior of underground cracks, analysis and detection were attempted on multiple acoustic emission (AE) events. The multiple AE is a phenomenon in which multiple AE signals generated by underground cracks developed in an extremely short time interval are superimposed, and observed as one AE event. The multiple AE signal consists of two AE signals, whereas the second P-wave is supposed to have been inputted before the first S-wave is inputted. The first P-wave is inputted first, where linear three-dimensional particle movements are observed, but the movements are made random due to scattering and sensor characteristics. When the second P-wave is inputted, the linear particle movements are observed again, but are superimposed with the existing input signals and become multiple AE, which creates poor S/N ratio. The multiple AE detection determines it a multiple AE event when three conditions are met, i. e. a condition of equivalent time interval of a maximum value in a scalogram analysis, a condition of P-wave vibrating direction, and a condition of the linear particle movement. Seventy AE signals observed in the Kakkonda geothermal field were analyzed and AE signals that satisfy the multiple AE were detected. However, further development is required on an analysis method with high resolution for the time. 4 refs., 4 figs.

  13. Comparison of a portable micro-X-ray fluorescence spectrometry with inductively coupled plasma atomic emission spectrometry for the ancient ceramics analysis

    International Nuclear Information System (INIS)

    Papadopoulou, D.N.; Zachariadis, G.A.; Anthemidis, A.N.; Tsirliganis, N.C.; Stratis, J.A.

    2004-01-01

    Two multielement instrumental methods of analysis, micro X-ray fluorescence spectrometry (micro-XRF) and inductively coupled plasma atomic emission spectrometry (ICP-AES) were applied for the analysis of 7th and 5th century B.C. ancient ceramic sherds in order to evaluate the above two methods and to assess the potential to use the current compact and portable micro-XRF instrument for the in situ analysis of ancient ceramics. The distinguishing factor of interest is that micro-XRF spectrometry offers the possibility of a nondestructive analysis, an aspect of primary importance in the compositional analysis of cultural objects. Micro-XRF measurements were performed firstly directly on the ceramic sherds with no special pretreatment apart from surface cleaning (micro-XRF on sherds) and secondly on pressed pellet disks which were prepared for each ceramic sherd (micro-XRF on pellet). For the ICP-AES determination of elements, test solutions were prepared by the application of a microwave-assisted decomposition procedure in closed high-pressure PFA vessels. Also, the standard reference material SARM 69 was used for the efficiency calibration of the micro-XRF instrument and was analysed by both methods. In order to verify the calibration, the standard reference materials NCS DC 73332 and SRM620 as well as the reference materials AWI-1 and PRI-1 were analysed by micro-XRF. Elemental concentrations determined by the three analytical procedures (ICP-AES, micro-XRF on sherds and micro-XRF on pellets) were statistically treated by correlation analysis and Student's t-test (at the 95% confidence level)

  14. Comparison of a portable micro-X-ray fluorescence spectrometry with inductively coupled plasma atomic emission spectrometry for the ancient ceramics analysis

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulou, D.N. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece); Zachariadis, G.A. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece); Anthemidis, A.N. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece); Tsirliganis, N.C. [Archaeometry Laboratory, Cultural and Educational Technology Institute, Tsimiski 58, GR-67100, Xanthi (Greece); Stratis, J.A. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece)]. E-mail: jstratis@chem.auth.gr

    2004-12-01

    Two multielement instrumental methods of analysis, micro X-ray fluorescence spectrometry (micro-XRF) and inductively coupled plasma atomic emission spectrometry (ICP-AES) were applied for the analysis of 7th and 5th century B.C. ancient ceramic sherds in order to evaluate the above two methods and to assess the potential to use the current compact and portable micro-XRF instrument for the in situ analysis of ancient ceramics. The distinguishing factor of interest is that micro-XRF spectrometry offers the possibility of a nondestructive analysis, an aspect of primary importance in the compositional analysis of cultural objects. Micro-XRF measurements were performed firstly directly on the ceramic sherds with no special pretreatment apart from surface cleaning (micro-XRF on sherds) and secondly on pressed pellet disks which were prepared for each ceramic sherd (micro-XRF on pellet). For the ICP-AES determination of elements, test solutions were prepared by the application of a microwave-assisted decomposition procedure in closed high-pressure PFA vessels. Also, the standard reference material SARM 69 was used for the efficiency calibration of the micro-XRF instrument and was analysed by both methods. In order to verify the calibration, the standard reference materials NCS DC 73332 and SRM620 as well as the reference materials AWI-1 and PRI-1 were analysed by micro-XRF. Elemental concentrations determined by the three analytical procedures (ICP-AES, micro-XRF on sherds and micro-XRF on pellets) were statistically treated by correlation analysis and Student's t-test (at the 95% confidence level)

  15. The Institute on Climate and Planets (ICP): A Research Education Program

    Science.gov (United States)

    Carlson, Barbara (Technical Monitor)

    2003-01-01

    Giving students a fair start to become productive and responsible contributors in the 21st century workforce and society depends on our ability to help them develop: (1) A global view of the world; (2) Problem-solving and/or reasoning abilities; (3) Basic scientific and technical literacy; and (4) A multi-disciplinary understanding of how humans and nature interact with the earth system. The Institute on Climate and Planets (ICP) in New York City is NASA Goddard Institute for Space Studies' (GISS) response to the national challenge to give students a fair start to become productive in America's workforce and society, GISS is part of the Earth Science Director at NASA Goddard Space Flight Center in Maryland and a component of Columbia University's Earth Institute, a university-wide initiative whose mission is to understand our planet so as to enhance its sustainability. In 1994 Jim Hansen, several of his GISS and Columbia University colleagues and Fitzgerald Bramwell, the former Director of the New York City Alliance for Minority Participation at City University of New York, launched the ICP. ICP contributes to NASA education and minority outreach goals by directly involving underrepresented college, high school and junior high school students and their educators in research. ICP takes advantage of the interest of many civil servants and Columbia University research scientists at GISS to involve students and educators on multi-level research teams working on problems at the core of NASA's Earth Science Enterprise - advancing our understanding of Earth s climate, climate variability, and climate impacts.

  16. Accurate determination of Curium and Californium isotopic ratios by inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) in 248Cm samples for transmutation studies

    Energy Technology Data Exchange (ETDEWEB)

    Gourgiotis, A.; Isnard, H.; Aubert, M.; Dupont, E.; AlMahamid, I.; Cassette, P.; Panebianco, S.; Letourneau, A.; Chartier, F.; Tian, G.; Rao, L.; Lukens, W.

    2011-02-01

    The French Atomic Energy Commission has carried out several experiments including the mini-INCA (INcineration of Actinides) project for the study of minor-actinide transmutation processes in high intensity thermal neutron fluxes, in view of proposing solutions to reduce the radiotoxicity of long-lived nuclear wastes. In this context, a Cm sample enriched in {sup 248}Cm ({approx}97 %) was irradiated in thermal neutron flux at the High Flux Reactor (HFR) of the Laue-Langevin Institute (ILL). This work describes a quadrupole ICP-MS (ICP-QMS) analytical procedure for precise and accurate isotopic composition determination of Cm before sample irradiation and of Cm and Cf after sample irradiation. The factors that affect the accuracy and reproducibility of isotopic ratio measurements by ICP-QMS, such as peak centre correction, detector dead time, mass bias, abundance sensitivity and hydrides formation, instrumental background, and memory blank were carefully evaluated and corrected. Uncertainties of the isotopic ratios, taking into account internal precision of isotope ratio measurements, peak tailing, and hydrides formations ranged from 0.3% to 1.3%. This uncertainties range is quite acceptable for the nuclear data to be used in transmutation studies.

  17. Unbelievable security : Matching AES using public key systems

    NARCIS (Netherlands)

    Lenstra, A.K.; Boyd, C.

    2001-01-01

    The Advanced Encryption Standard (AES) provides three levels of security: 128, 192, and 256 bits. Given a desired level of security for the AES, this paper discusses matching public key sizes for RSA and the ElGamal family of protocols. For the latter both traditional multiplicative groups of finite

  18. Integrated care pathways for airway diseases (AIRWAYS-ICPs)

    NARCIS (Netherlands)

    Bousquet, J.; Addis, A.; Adcock, I.; Agache, I.; Agusti, A.; Alonso, A.; Annesi-Maesano, I.; Anto, J. M.; Bachert, C.; Baena-Cagnani, C. E.; Bai, C.; Baigenzhin, A.; Barbara, C.; Barnes, P. J.; Bateman, E. D.; Beck, L.; Bedbrook, A.; Bel, E. H.; Benezet, O.; Bennoor, K. S.; Benson, M.; Bernabeu-Wittel, M.; Bewick, M.; Bindslev-Jensen, C.; Blain, H.; Blasi, F.; Bonini, M.; Bonini, S.; Boulet, L. P.; Bourdin, A.; Bourret, R.; Bousquet, P. J.; Brightling, C. E.; Briggs, A.; Brozek, J.; Buhl, R.; Bush, A.; Caimmi, D.; Calderon, M.; Calverley, P.; Camargos, P. A.; Camuzat, T.; Canonica, G. W.; Carlsen, K. H.; Casale, T. B.; Cazzola, M.; Cepeda Sarabia, A. M.; Cesario, A.; Chen, Y. Z.; Chkhartishvili, E.; Chavannes, N. H.; Chiron, R.; Chuchalin, A.; Chung, K. F.; Cox, L.; Crooks, G.; Crooks, M. G.; Cruz, A. A.; Custovic, A.; Dahl, R.; Dahlen, S. E.; de Blay, F.; Dedeu, T.; Deleanu, D.; Demoly, P.; Devillier, P.; Didier, A.; Dinh-Xuan, A. T.; Djukanovic, R.; Dokic, D.; Douagui, H.; Dubakiene, R.; Eglin, S.; Elliot, F.; Emuzyte, R.; Fabbri, L.; Fink Wagner, A.; Fletcher, M.; Fokkens, W. J.; Fonseca, J.; Franco, A.; Frith, P.; Furber, A.; Gaga, M.; Garcés, J.; Garcia-Aymerich, J.; Gamkrelidze, A.; Gonzales-Diaz, S.; Gouzi, F.; Guzmán, M. A.; Haahtela, T.; Harrison, D.; Hayot, M.; Heaney, L. G.; Heinrich, J.; Hellings, P. W.; Hooper, J.; Humbert, M.; Hyland, M.; Iaccarino, G.; Jakovenko, D.; Jardim, J. R.; Jeandel, C.; Jenkins, C.; Johnston, S. L.; Jonquet, O.; Joos, G.; Jung, K. S.; Kalayci, O.; Karunanithi, S.; Keil, T.; Khaltaev, N.; Kolek, V.; Kowalski, M. L.; Kull, I.; Kuna, P.; Kvedariene, V.; Le, L. T.; Lodrup Carlsen, K. C.; Louis, R.; MacNee, W.; Mair, A.; Majer, I.; Manning, P.; de Manuel Keenoy, E.; Masjedi, M. R.; Melen, E.; Melo-Gomes, E.; Menzies-Gow, A.; Mercier, G.; Mercier, J.; Michel, J. P.; Miculinic, N.; Mihaltan, F.; Milenkovic, B.; Molimard, M.; Momas, I.; Montilla-Santana, A.; Morais-Almeida, M.; Morgan, M.; N'Diaye, M.; Nafti, S.; Nekam, K.; Neou, A.; Nicod, L.; O'Hehir, R.; Ohta, K.; Paggiaro, P.; Palkonen, S.; Palmer, S.; Papadopoulos, N. G.; Papi, A.; Passalacqua, G.; Pavord, I.; Pigearias, B.; Plavec, D.; Postma, D. S.; Price, D.; Rabe, K. F.; Radier Pontal, F.; Redon, J.; Rennard, S.; Roberts, J.; Robine, J. M.; Roca, J.; Roche, N.; Rodenas, F.; Roggeri, A.; Rolland, C.; Rosado-Pinto, J.; Ryan, D.; Samolinski, B.; Sanchez-Borges, M.; Schünemann, H. J.; Sheikh, A.; Shields, M.; Siafakas, N.; Sibille, Y.; Similowski, T.; Small, I.; Sola-Morales, O.; Sooronbaev, T.; Stelmach, R.; Sterk, P. J.; Stiris, T.; Sud, P.; Tellier, V.; To, T.; Todo-Bom, A.; Triggiani, M.; Valenta, R.; Valero, A. L.; Valiulis, A.; Valovirta, E.; van Ganse, E.; Vandenplas, O.; Vasankari, T.; Vestbo, J.; Vezzani, G.; Viegi, G.; Visier, L.; Vogelmeier, C.; Vontetsianos, T.; Wagstaff, R.; Wahn, U.; Wallaert, B.; Whalley, B.; Wickman, M.; Williams, D. M.; Wilson, N.; Yawn, B. P.; Yiallouros, P. K.; Yorgancioglu, A.; Yusuf, O. M.; Zar, H. J.; Zhong, N.; Zidarn, M.; Zuberbier, T.

    2014-01-01

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy and will

  19. Integrated care pathways for airway diseases (AIRWAYS-ICPs)

    NARCIS (Netherlands)

    Bousquet, J.; Addis, A.; Adcock, I.; Agache, I.; Agusti, A.; Alonso, A.; Annesi-Maesano, I.; Anto, J. M.; Bachert, C.; Baena-Cagnani, C. E.; Bai, C.; Baigenzhin, A.; Barbara, C.; Barnes, P. J.; Bateman, E. D.; Beck, L.; Bedbrook, A.; Bel, E. H.; Benezet, O.; Bennoor, K. S.; Benson, M.; Bernabeu-Wittel, M.; Bewick, M.; Bindslev-Jensen, C.; Blain, H.; Blasi, F.; Bonini, M.; Bonini, S.; Boulet, L. P.; Bourdin, A.; Bourret, R.; Bousquet, P. J.; Brightling, C. E.; Briggs, A.; Brozek, J.; Buh, R.; Bush, A.; Caimmi, D.; Calderon, M.; Calverley, P.; Camargos, P. A.; Camuzat, T.; Canonica, G. W.; Carlsen, K. H.; Casale, T. B.; Cazzola, M.; Sarabia, A. M. Cepeda; Cesario, A.; Chen, Y. Z.; Chkhartishvili, E.; Chavannes, N. H.; Chiron, R.; Chuchalin, A.; Chung, K. F.; Cox, L.; Crooks, G.; Crooks, M. G.; Cruz, A. A.; Custovic, A.; Dahl, R.; Dahlen, S. E.; De Blay, F.; Dedeu, T.; Deleanu, D.; Demoly, P.; Devillier, P.; Didier, A.; Dinh-Xuan, A. T.; Djukanovic, R.; Dokic, D.; Douagui, H.; Dubakiene, R.; Eglin, S.; Elliot, F.; Emuzyte, R.; Fabbri, L.; Wagner, A. Fink; Fletcher, M.; Fokkens, W. J.; Fonseca, J.; Franco, A.; Frith, P.; Furber, A.; Gaga, M.; Garces, J.; Garcia-Aymerich, J.; Gamkrelidze, A.; Gonzales-Diaz, S.; Gouzi, F.; Guzman, M. A.; Haahtela, T.; Harrison, D.; Hayot, M.; Heaney, L. G.; Heinrich, J.; Hellings, P. W.; Hooper, J.; Humbert, M.; Hyland, M.; Iaccarino, G.; Jakovenko, D.; Jardim, J. R.; Jeandel, C.; Jenkins, C.; Johnston, S. L.; Jonquet, O.; Joos, G.; Jung, K. S.; Kalayci, O.; Karunanithi, S.; Keil, T.; Khaltaev, N.; Kolek, V.; Kowalski, M. L.; Kull, I.; Kuna, P.; Kvedariene, V.; Le, L. T.; Carlsen, K. C. Lodrup; Louis, R.; MacNee, W.; Mair, A.; Majer, I.; Manning, P.; Keenoy, E. de Manuel; Masjedi, M. R.; Meten, E.; Melo-Gomes, E.; Menzies-Gow, A.; Mercier, G.; Mercier, J.; Michel, J. P.; Miculinic, N.; Mihaltan, F.; Milenkovic, B.; Molimard, M.; Mamas, I.; Montilla-Santana, A.; Morais-Almeida, M.; Morgan, M.; N'Diaye, M.; Nafti, S.; Nekam, K.; Neou, A.; Nicod, L.; O'Hehir, R.; Ohta, K.; Paggiaro, P.; Palkonen, S.; Palmer, S.; Papadopoulos, N. G.; Papi, A.; Passalacqua, G.; Pavord, I.; Pigearias, B.; Plavec, D.; Postma, D. S.; Price, D.; Rabe, K. F.; Pontal, F. Radier; Redon, J.; Rennard, S.; Roberts, J.; Robine, J. M.; Roca, J.; Roche, N.; Rodenas, F.; Roggeri, A.; Rolland, C.; Rosado-Pinto, J.; Ryan, D.; Samolinski, B.; Sanchez-Borges, M.; Schunemann, H. J.; Sheikh, A.; Shields, M.; Siafakas, N.; Sibille, Y.; Similowski, T.; Small, I.; Sola-Morales, O.; Sooronbaev, T.; Stelmach, R.; Sterk, P. J.; Stiris, T.; Sud, P.; Tellier, V.; To, T.; Todo-Bom, A.; Triggiani, M.; Valenta, R.; Valero, A. L.; Valiulis, A.; Valovirta, E.; Van Ganse, E.; Vandenplas, O.; Vasankari, T.; Vestbo, J.; Vezzani, G.; Viegi, G.; Visier, L.; Vogelmeier, C.; Vontetsianos, T.; Wagstaff, R.; Wahn, U.; Wallaert, B.; Whalley, B.; Wickman, M.; Williams, D. M.; Wilson, N.; Yawn, B. P.; Yiallouros, P. K.; Yorgancioglu, A.; Yusuf, O. M.; Zar, H. J.; Zhong, N.; Zidarn, M.; Zuberbier, T.

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy and will

  20. Role of americium interference in analysis of samples containing rare earths

    International Nuclear Information System (INIS)

    Mohapatra, P.K.; Adya, V.C.; Thulasidas, S.K.; Bhattacharyya, A.; Kumar, Mithlesh; Godbole, S.V.; Manchanda, V.K.

    2007-01-01

    Quality control of nuclear fuel samples requires precise estimation of rare earths which have high neutron absorption cross sections and act as neutron poisons. Am is generated by nuclear decay where as lanthanides may be present as impurities picked up during reprocessing/fuel fabrication. Precise estimation of the rare earths by ICP-AES method in presence of 241 Am is a challenging task due to the likelihood of spectral interference of the latter. Rare earths impurities in the purified Am sample were estimated by ICP-AES method. Known amounts of the rare earths viz. Sm, Eu, Dy and Gd were used as synthetic sample and the interference due to Am was investigated. (author)

  1. Development of ICP-MS and ICP-OES methods for determination of gadolinium in samples related to hospital waste water treatment

    Czech Academy of Sciences Publication Activity Database

    Bendakovská, L.; Krejčovská, A.; Černohorský, T.; Zelenková, Jana

    2016-01-01

    Roč. 70, č. 9 (2016), s. 1155-1165 ISSN 0366-6352 Institutional support: RVO:67985874 Keywords : gadolinium * rare-earth elements * bioaccumulation * gadolinium anomaly * inductively coupled plasma mass spectrometry (ICP-MS) * inductively coupled plasma optical emission spectrometry (ICP-OES) Subject RIV: BK - Fluid Dynamics Impact factor: 1.258, year: 2016

  2. Measurements of β or α emitter long lived radionuclides using inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Provitina, O.

    1993-01-01

    The measurement of long-lived radionuclides is highly important for characterizing nuclear wastes for their later storage. The main techniques for characterizing these isotopes are α spectrometry, β counting and γ spectrometry. The large period of these isotopes leads to low specific activity needing time consuming measurements in order to obtain significant signals. Moreover, the radiometric techniques are often limited by problems of interferences involving several steps of pretreatments. Among these steps, the specific extraction with crown ethers is highly selective for the separation of 99 Tc, 129 I and 135 Cs particularly. The radiometric techniques are here replaced by inductively coupled plasma mass spectroscopy (ICP-MS) the advantages of which are: few interferences, sensitivity which does not depend on the radiologic period as compared to radiochemistry. ICP-MS can then measure 237 Np in enriched uranium matrix and thereby reduce by a factor of 4 the sample pretreatment and the duration of the analysis usually performed by α spectrometry. Another technique, electrothermal vaporization (ETV), is consequently used. Crown ether extraction-ETV-ICP-MS is employed for measuring the long lived radionuclides 99 Tc and 129 I. The conditions of the extraction and the parameters of the ETV and the ICP-MS are studied and optimized. The methods optimized (extraction, electrothermal vaporization) are validated in the case of 99 Tc, in real samples. The spike method is required to quantify technetium, the quantification with calibration leading to bad results. The results obtained are in good agreement with the expected values. Extraction of technetium on anionic resin and its measurement by the spike method with pneumatic nebulization-ICP-MS is also performed on other samples. Measured values are also in agreement with expected values, but the method of extraction is more time consuming (half a day) than the extraction with crown ether (one hour). (author). 54 figs

  3. Undergraduate Observations of Separation and Position Angle of Double Stars ARY 6 AD and ARY 6 AE at Manzanita Observatory

    Science.gov (United States)

    Hoffert, Michael J.; Weise, Eric; Clow, Jenna; Hirzel, Jacquelyn; Leeder, Brett; Molyneux, Scott; Scutti, Nicholas; Spartalis, Sarah; Tokuhara, Corey

    2014-05-01

    Six beginning astronomy students, part of an undergraduate stellar astronomy course, one advanced undergraduate student assistant, and a professor measured the position angles and separations of Washington Double Stars (WDS) 05460 + 2119 (also known as ARY 6 AD and ARY 6 AE). The measurements were made at the Manzanita Observatory (116° 20'42" W, 32° 44' 5" N) of the Tierra Astronomical Institute on 10 Blackwood Rd. in Boulevard, California (www.youtube.com/watch?v=BHVdcMGBGDU), at an elevation of 4,500 ft. A Celestron 11" HD Edge telescope was used to measure the position angles and separations of ARY 6 AD and ARY 6 AE. The averages of our measurements are as follows: separation AD: trial 1 124.1 arcseconds and trial 2 124.5 arcseconds. The average of separation for AE: trial 1 73.3 arcseconds and trial 2 73.8 arcseconds. The averages of position angle for AD: trial 1 159.9 degrees and trial 2 161.3 degrees. The averages of position angle for AE: trial 1 232.6 degrees and trial 2 233.7 degrees.

  4. Dependence of distribution parameters of large-scale electric fields on Kp and AE indices of geomagnetic disturbance

    International Nuclear Information System (INIS)

    Uvarov, V.M.; Kandibolotskaya, M.A.; Moskvin, I.V.

    1989-01-01

    Regression equations, which link potential drop ΔΦ PC , kV with K P in polar cap and which are generalized in the form of ΔΦ PC =20+15K P , are obtained on the basis of three groups of published data on measurements conducted using cosmic vehicles and incoherent scattering facility. Regression equation for ΔΦ PC and AE is obtained using data of DE-2 CV: ΔΦ PC =31.65±12.50 (AE/100). Usage of the large file-mean initial data of ΔΦ RS values realized filtration and determined high, no lower, than 0.9, coefficients of correlation. Regression equations, which link P index of precipitation and invariant latitudes of convection lower boundary in the night and morning sectors with K P -index, are presented

  5. Development of methodologies used in the areas of safeguards and nuclear forensics based on LA-HR-ICP-MS technique; Desenvolvimento de metodologias utilizadas nas areas de salvaguardas e forense nuclear baseadas na tecnica LA-HR-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Marin, Rafael Coelho

    2013-07-01

    Environmental sampling performed by means of swipe samples is a methodology frequently employed by International Atomic Energy Agency (IAEA) to verify if the signatory States of the Safeguards Agreements are conducing unauthorized activities. Swipe samples analysis is complementary to the Safeguards ordinary procedures used to verify the information given by the States. In this work it was described a methodology intending to strengthen the nuclear safeguards and nuclear forensics procedures. The proposal is to study and evaluate the laser ablation high resolution inductively coupled plasma mass spectrometry (LA-HR-ICP-MS) technique as an alternative to analyze the real-life swipe samples. The precision achieved through the standard (CRM - 125A) measurements, represented by the relative standard deviation (RSD), was respectively 1.3 %, 0.2 % e 7.6 % for the {sup 234}U/{sup 238}U, {sup 235}U/{sup 238}U e {sup 236}U/{sup 238}U isotopes ratios. The percent uncertainties (u %), which covers the RSD, ranged from 3.5 % to 29.8 % to the {sup 235}U/{sup 238}U measurements and from 16.6 % to 42.9 % to the {sup 234}U/{sup 238}U isotope ratio. These results were compatible with former studies performed by the LA-HR-ICP-MS that analyzed real-life swipe samples collected at a nuclear facility. Swipe samples collected from several points of the nuclear facility presented enrichment level ranging from (2.3 ± 0.7) % (sample 3) to (17.3 ± 2.8) % (sample 18). They also allowed detecting different enrichment levels within the facility. (author)

  6. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products.

    Science.gov (United States)

    Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.

  7. Determination of 210Pb at ultra-trace levels in water by ICP-MS

    International Nuclear Information System (INIS)

    Lariviere, D.; Reiber, K.M.; Evans, R.D.; Cornett, R.J.

    2005-01-01

    210 Pb (t 1/2 = 22.26 years) is one of the most difficult naturally occurring radionuclides to analyze directly via radiometric measurement due to its low-energy radioactive decay. In this work, inductively coupled plasma mass spectrometry (ICP-MS) was investigated as a possible alternative to radiometric counting for the determination of 210 Pb. The formation of isobaric and polyatomic (molecular) interferences was studied and various strategies (i.e. co-precipitation, extraction chromatography, and derivatization) were tested to assess their usefulness in reducing these interferences. In addition, the potential of these strategies as pre-concentration methods was demonstrated. A 210 Pb pre-concentration of >300-fold and recoveries of 63-73% were obtained using a combined co-precipitation and extraction chromatography protocol followed by derivatization using an ethylating reagent. The abundance sensitivity at m/z = 210 in the presence of stable Pb was also investigated for three types of mass spectrometers (sector-field (ICP-SFMS), quadrupole-based (ICP-QMS), and quadrupole-based with a dynamic reaction cell (ICP-QMS (DRC))). Finally, the method was applied to determine 210 Pb in water samples and a detection limit of 90 mBq L -1 (10 pg L -1 ) was obtained

  8. AES Encryption Algorithm Optimization Based on 64-bit Processor Android Platform

    Directory of Open Access Journals (Sweden)

    ZHAO Jun

    2017-06-01

    Full Text Available Algorithm implemented on the mobile phone is different from one on PC. It requires little storage space and low power consumption. Standard AES S-box design uses look up table,and has high complexity and high power consumption,so it needs to be optimized when used in mobile phones. In our optimization AES encryption algorithm,the packet length is expanded to 256 bits,which would increase the security of our algorithm; look up table is replaced by adding the affine transformation based on inversion,which would reduce the storage space; operation is changed into 16-bit input and 64-bit output by merging the three steps,namely SubWords,ShiftRows MixColumns and AddRoundKey,which would improve the operation efficiency of the algorithm. The experimental results show that our algorithm not only can greatly enhance the encryption strength,but also maintain high computing efficiency.

  9. AES, Automated Construction Cost Estimation System

    International Nuclear Information System (INIS)

    Holder, D.A.

    1995-01-01

    A - Description of program or function: AES (Automated Estimating System) enters and updates the detailed cost, schedule, contingency, and escalation information contained in a typical construction or other project cost estimates. It combines this information to calculate both un-escalated and escalated and cash flow values for the project. These costs can be reported at varying levels of detail. AES differs from previous versions in at least the following ways: The schedule is entered at the WBS-Participant, Activity level - multiple activities can be assigned to each WBS-Participant combination; the spending curve is defined at the schedule activity level and a weighing factor is defined which determines percentage of cost for the WBS-Participant applied to the schedule activity; Schedule by days instead of Fiscal Year/Quarter; Sales Tax is applied at the Line Item Level- a sales tax codes is selected to indicate Material, Large Single Item, or Professional Services; a 'data filter' has been added to allow user to define data the report is to be generated for. B - Method of solution: Average Escalation Rate: The average escalation for a Bill of is calculated in three steps. 1. A table of quarterly escalation factors is calculated based on the base fiscal year and quarter of the project entered in the estimate record and the annual escalation rates entered in the Standard Value File. 2. The percentage distribution of costs by quarter for the Bill of Material is calculated based on the schedule entered and the curve type. 3. The percent in each fiscal year and quarter in the distribution is multiplied by the escalation factor for the fiscal year and quarter. The sum of these results is the average escalation rate for that Bill of Material. Schedule by curve: The allocation of costs to specific time periods is dependent on three inputs, starting schedule date, ending schedule date, and the percentage of costs allocated to each quarter. Contingency Analysis: The

  10. Advanced functional materials in solid phase extraction for ICP-MS determination of trace elements and their species - A review.

    Science.gov (United States)

    He, Man; Huang, Lijin; Zhao, Bingshan; Chen, Beibei; Hu, Bin

    2017-06-22

    For the determination of trace elements and their species in various real samples by inductively coupled plasma mass spectrometry (ICP-MS), solid phase extraction (SPE) is a commonly used sample pretreatment technique to remove complex matrix, pre-concentrate target analytes and make the samples suitable for subsequent sample introduction and measurements. The sensitivity, selectivity/anti-interference ability, sample throughput and application potential of the methodology of SPE-ICP-MS are greatly dependent on SPE adsorbents. This article presents a general overview of the use of advanced functional materials (AFMs) in SPE for ICP-MS determination of trace elements and their species in the past decade. Herein the AFMs refer to the materials featuring with high adsorption capacity, good selectivity, fast adsorption/desorption dynamics and satisfying special requirements in real sample analysis, including nanometer-sized materials, porous materials, ion imprinting polymers, restricted access materials and magnetic materials. Carbon/silica/metal/metal oxide nanometer-sized adsorbents with high surface area and plenty of adsorption sites exhibit high adsorption capacity, and porous adsorbents would provide more adsorption sites and faster adsorption dynamics. The selectivity of the materials for target elements/species can be improved by using physical/chemical modification, ion imprinting and restricted accessed technique. Magnetic adsorbents in conventional batch operation offer unique magnetic response and high surface area-volume ratio which provide a very easy phase separation, greater extraction capacity and efficiency over conventional adsorbents, and chip-based magnetic SPE provides a versatile platform for special requirement (e.g. cell analysis). The performance of these adsorbents for the determination of trace elements and their species in different matrices by ICP-MS is discussed in detail, along with perspectives and possible challenges in the future

  11. The determination of long life radionuclides by means of sector field ICP mass spectrometry

    International Nuclear Information System (INIS)

    Kerl, W.; Becker, J.S.; Dietze, H.J.; Dannecker, W.

    1996-01-01

    Different analytical processes for determining long life radionuclides by means of double-focussing sector field ICP mass spectrometry are described. In determining long life radionuclides by means of ICP-MS, on the one hand the analytical problem areas are in the interference of isobaric atom or molecule ions (eg: 151 Eu + - 151 Sm + , 79 Se + - 39 Ar 40 ArH + ) and on the other hand in the high detection limits when using commercial sample introduction systems (eg: For 129 I). An online coupling of HPLC and ICP-MS was built up for the separation of isobaric atom ions and was tested for the separation of isobaric atom ions and was tested for its efficiency in the separation of lanthanides. Special sample introduction systems for ICP-MS were developed for the analysis of 129 I, by which the sensitivity of detection can be appreciably improved compared to commercial sample introduction systems. (orig.) [de

  12. Measurement of 240Pu/239Pu isotopic ratios in soils from the Marshall Islands using ICP-MS.

    Science.gov (United States)

    Muramatsu, Y; Hamilton, T; Uchida, S; Tagami, K; Yoshida, S; Robison, W

    2001-10-20

    Nuclear weapons tests conducted by the United States in the Marshall Islands produced significant quantities of regional or tropospheric fallout contamination. Here we report on some preliminary inductively coupled plasma-mass spectrometry (ICP-MS) measurements of plutonium isolated from seven composite soil samples collected from Bikini, Enewetak and Rongelap Atolls in the northern Marshall Islands. These data show that 240Pu/239Pu isotopic signatures in surface soils from the Marshall Island vary significantly and could potentially be used to help quantify the range and extent of fallout deposition (and associated impacts) from specific weapons tests. 137Cs and 60Co were also determined on the same set of soil samples for comparative purposes.

  13. Measurement of 240Pu/239Pu isotopic ratios in soils from the Marshall Islands using ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Muramatsu, Y.; Uchida, S.; Tagami, K.; Yoshida, S. [Environmental and Toxicological Researches Group, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage-ku, 263-8555 Chiba (Japan); Hamilton, T.; Robison, W. [Health and Ecological Assessment Division, Lawrence Livermore National Laboratory, P.O. Box 808, L-453, 94551-0808 Livermore, CA (United States)

    2001-10-20

    Nuclear weapons tests conducted by the United States in the Marshall Islands produced significant quantities of regional or tropospheric fallout contamination. Here we report on some preliminary inductively coupled plasma-mass spectrometry (ICP-MS) measurements of plutonium isolated from seven composite soil samples collected from Bikini, Enewetak and Rongelap Atolls in the northern Marshall Islands. These data show that 240Pu/239Pu isotopic signatures in surface soils from the Marshall Island vary significantly and could potentially be used to help quantify the range and extent of fallout deposition (and associated impacts) from specific weapons tests. 137Cs and 60Co were also determined on the same set of soil samples for comparative purposes.

  14. Measurement of 240Pu/239Pu isotopic ratios in soils from the Marshall Islands using ICP-MS

    International Nuclear Information System (INIS)

    Muramatsu, Y.; Uchida, S.; Tagami, K.; Yoshida, S.; Hamilton, T.; Robison, W.

    2001-01-01

    Nuclear weapons tests conducted by the United States in the Marshall Islands produced significant quantities of regional or tropospheric fallout contamination. Here we report on some preliminary inductively coupled plasma-mass spectrometry (ICP-MS) measurements of plutonium isolated from seven composite soil samples collected from Bikini, Enewetak and Rongelap Atolls in the northern Marshall Islands. These data show that 240Pu/239Pu isotopic signatures in surface soils from the Marshall Island vary significantly and could potentially be used to help quantify the range and extent of fallout deposition (and associated impacts) from specific weapons tests. 137Cs and 60Co were also determined on the same set of soil samples for comparative purposes

  15. Protein arginine methyltransferase 1 regulates herpes simplex virus replication through ICP27 RGG-box methylation

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jungeun; Shin, Bongjin; Park, Eui-Soon; Yang, Sujeong; Choi, Seunga [Department of Microbiology, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of); BK21 Bio Brain Center, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of); Kang, Misun [Department of Microbiology, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of); Rho, Jaerang, E-mail: jrrho@cnu.ac.kr [Department of Microbiology, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of); BK21 Bio Brain Center, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of); GRAST, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of)

    2010-01-01

    Protein arginine methylation is involved in viral infection and replication through the modulation of diverse cellular processes including RNA metabolism, cytokine signaling, and subcellular localization. It has been suggested previously that the protein arginine methylation of the RGG-box of ICP27 is required for herpes simplex virus type-1 (HSV-1) viral replication and gene expression in vivo. However, a cellular mediator for this process has not yet been identified. In our current study, we show that the protein arginine methyltransferase 1 (PRMT1) is a cellular mediator of the arginine methylation of ICP27 RGG-box. We generated arginine substitution mutants in this domain and examined which arginine residues are required for methylation by PRMT1. R138, R148 and R150 were found to be the major sites of this methylation but additional arginine residues serving as minor methylation sites are still required to sustain the fully methylated form of ICP27 RGG. We also demonstrate that the nuclear foci-like structure formation, SRPK interactions, and RNA-binding activity of ICP27 are modulated by the arginine methylation of the ICP27 RGG-box. Furthermore, HSV-1 replication is inhibited by hypomethylation of this domain resulting from the use of general PRMT inhibitors or arginine mutations. Our data thus suggest that the PRMT1 plays a key role as a cellular regulator of HSV-1 replication through ICP27 RGG-box methylation.

  16. Determination of trace elements in soy milk using ICP atomic emission spectrometry

    International Nuclear Information System (INIS)

    Tanaka, Satoko; Chayama, Kenji

    2009-01-01

    The present study investigated the optimal method for the multi-element quantification of 9 elements in soy milk: calcium, copper, iron, potassium, magnesium, manganese, sodium, phosphorus, and zinc. Results obtained using ICP atomic emission spectrometry were compared with those obtained by atomic absorption spectrometry, which is the standard method. The same sample was measured using both ICP atomic emission spectrometry and atomic absorption spectrometry. The percentage of minerals recovered by ICP atomic emission spectrometry ranged from 99.3% to 102%, which was equivalent to that by atomic absorption spectrometry. Therefore, a good result with standard deviation was obtained. The mineral contents of 16 samples of commercially-available soy milk products were measured. The Cu content was significantly proportional to the amount of soybean solids (P < 0.001). Moreover, although relation-ships did not attain statistical significance, the consents of Fe, Zn, K, Mg and P were proportional to the amount of soybean solids, and were highest in soy milk, followed by prepared soy milk and so milk beverage. The Ca content of modified soy milk was significantly higher than that of soy milk and soy milk-based beverages (P < 0.001). Furthermore, the Na content in soy milk was significantly lower. (author)

  17. Acoustic Emission Monitoring of Incipient Failure in Journal Bearings( III ) - Development of AE Diagnosis System for Journal Bearings -

    International Nuclear Information System (INIS)

    Chung, Min Hwa; Cho, Yong Sang; Yoon, Dong Jin; Kwon, Oh Yang

    1996-01-01

    For the condition monitoring of the journal bearing in rotating machinery, a system for their diagnosis by acoustic emission(AE) was developed. AE has been used to detect abnormal conditions in the bearing system. It was found from the field application study as well as the laboratory experiment using a simulated journal bearing system that AE RMS voltage was the most efficient parameter for the purpose of current study. Based on the above results, algorithms and judgement criteria for the diagnosis system was established. The system is composed of four parts as follows: the sensing part including AE sensor and preamplifier, the signal processing part for RMS-to-DC conversion to measure AE ms voltage, the interface part for transferring RMS voltage data into PC using A/D converter, and the software part including the graphic display of bearing conditions and the diagnosis program

  18. The global compendium of Aedes aegypti and Ae. albopictus occurrence

    Science.gov (United States)

    Kraemer, Moritz U. G.; Sinka, Marianne E.; Duda, Kirsten A.; Mylne, Adrian; Shearer, Freya M.; Brady, Oliver J.; Messina, Jane P.; Barker, Christopher M.; Moore, Chester G.; Carvalho, Roberta G.; Coelho, Giovanini E.; van Bortel, Wim; Hendrickx, Guy; Schaffner, Francis; Wint, G. R. William; Elyazar, Iqbal R. F.; Teng, Hwa-Jen; Hay, Simon I.

    2015-07-01

    Aedes aegypti and Ae. albopictus are the main vectors transmitting dengue and chikungunya viruses. Despite being pathogens of global public health importance, knowledge of their vectors’ global distribution remains patchy and sparse. A global geographic database of known occurrences of Ae. aegypti and Ae. albopictus between 1960 and 2014 was compiled. Herein we present the database, which comprises occurrence data linked to point or polygon locations, derived from peer-reviewed literature and unpublished studies including national entomological surveys and expert networks. We describe all data collection processes, as well as geo-positioning methods, database management and quality-control procedures. This is the first comprehensive global database of Ae. aegypti and Ae. albopictus occurrence, consisting of 19,930 and 22,137 geo-positioned occurrence records respectively. Both datasets can be used for a variety of mapping and spatial analyses of the vectors and, by inference, the diseases they transmit.

  19. Monovalent Cation Activation of the Radical SAM Enzyme Pyruvate Formate-Lyase Activating Enzyme.

    Science.gov (United States)

    Shisler, Krista A; Hutcheson, Rachel U; Horitani, Masaki; Duschene, Kaitlin S; Crain, Adam V; Byer, Amanda S; Shepard, Eric M; Rasmussen, Ashley; Yang, Jian; Broderick, William E; Vey, Jessica L; Drennan, Catherine L; Hoffman, Brian M; Broderick, Joan B

    2017-08-30

    Pyruvate formate-lyase activating enzyme (PFL-AE) is a radical S-adenosyl-l-methionine (SAM) enzyme that installs a catalytically essential glycyl radical on pyruvate formate-lyase. We show that PFL-AE binds a catalytically essential monovalent cation at its active site, yet another parallel with B 12 enzymes, and we characterize this cation site by a combination of structural, biochemical, and spectroscopic approaches. Refinement of the PFL-AE crystal structure reveals Na + as the most likely ion present in the solved structures, and pulsed electron nuclear double resonance (ENDOR) demonstrates that the same cation site is occupied by 23 Na in the solution state of the as-isolated enzyme. A SAM carboxylate-oxygen is an M + ligand, and EPR and circular dichroism spectroscopies reveal that both the site occupancy and the identity of the cation perturb the electronic properties of the SAM-chelated iron-sulfur cluster. ENDOR studies of the PFL-AE/[ 13 C-methyl]-SAM complex show that the target sulfonium positioning varies with the cation, while the observation of an isotropic hyperfine coupling to the cation by ENDOR measurements establishes its intimate, SAM-mediated interaction with the cluster. This monovalent cation site controls enzyme activity: (i) PFL-AE in the absence of any simple monovalent cations has little-no activity; and (ii) among monocations, going down Group 1 of the periodic table from Li + to Cs + , PFL-AE activity sharply maximizes at K + , with NH 4 + closely matching the efficacy of K + . PFL-AE is thus a type I M + -activated enzyme whose M + controls reactivity by interactions with the cosubstrate, SAM, which is bound to the catalytic iron-sulfur cluster.

  20. AES ALGORITHM IMPLEMENTATION IN PROGRAMMING LANGUAGES

    Directory of Open Access Journals (Sweden)

    Luminiţa DEFTA

    2010-12-01

    Full Text Available Information encryption represents the usage of an algorithm to convert an unknown message into an encrypted one. It is used to protect the data against unauthorized access. Protected data can be stored on a media device or can be transmitted through the network. In this paper we describe a concrete implementation of the AES algorithm in the Java programming language (available from Java Development Kit 6 libraries and C (using the OpenSSL library. AES (Advanced Encryption Standard is an asymmetric key encryption algorithm formally adopted by the U.S. government and was elected after a long process of standardization.

  1. Introducing wet aerosols into the static high sensitivity ICP (SHIP)

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, Andy; Engelhard, Carsten; Sperling, Michael; Buscher, Wolfgang [University of Muenster, Institute of Inorganic and Analytical Chemistry, Muenster (Germany)

    2007-08-15

    A demountable design of the static high sensitivity ICP (SHIP) for optical emission spectrometry is presented, and its use as an excitation source with the introduction of wet aerosols was investigated. Aerosols were produced by standard pneumatic sample introduction systems, namely a cross flow nebulizer, Meinhard nebulizer and PFA low flow nebulizer, which have been applied in conjunction with a double pass and a cyclonic spray chamber. The analytical capabilities of these sample introduction systems in combination with the SHIP system were evaluated with respect to the achieved sensitivity. It was found that a nebulizer tailored for low argon flow rates (0.3-0.5 L min{sup -1}) is best suited for the low flow plasma (SHIP). An optimization of all gas flow rates of the SHIP system with the PFA low flow nebulizer was carried out in a two-dimensional way with the signal to background ratio (SBR) and the robustness as optimization target parameters. Optimum conditions for a torch model with 1-mm injector tube were 0.25 and 0.36 L min{sup -1} for the plasma gas and the nebulizer gas, respectively. A torch model with a 2-mm injector tube was optimized to 0.4 L min{sup -1} for the plasma gas and 0.44 L min{sup -1} for the nebulizer gas. In both cases the SHIP system saves approximately 95% of the argon consumed by conventional inductively coupled plasma systems. The limits of detection were found to be in the low microgram per litre range and below for many elements, which was quite comparable to those of the conventional setup. Furthermore, the short-term stability and the wash out behaviour of the SHIP were investigated. Direct comparison with the conventional setup indicated that no remarkable memory effects were caused by the closed design of the torch. The analysis of a NIST SRM 1643e (Trace Elements in Water) with the SHIP yielded recoveries of 97-103% for 13 elements, measured simultaneously. (orig.)

  2. 15 CFR Appendix D to Part 30 - AES Filing Citation, Exemption and Exclusion Legends

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false AES Filing Citation, Exemption and... Appendix D to Part 30—AES Filing Citation, Exemption and Exclusion Legends I. USML Proof of Filing Citation AES ITN Example: AES X20060101987654. II. AES Proof of Filing Citation subpart A § 30.7 AES ITN...

  3. Flow sorting of C-genome chromosomes from wild relatives of wheat Aegilops markgrafii, Ae. triuncialis and Ae. cylindrica, and their molecular organization

    Czech Academy of Sciences Publication Activity Database

    Molnár, I.; Vrána, Jan; Farkas, A.; Kubaláková, Marie; Cseh, A.; Molnár-Láng, M.; Doležel, Jaroslav

    2015-01-01

    Roč. 116, č. 2 (2015), s. 189-200 ISSN 0305-7364 R&D Projects: GA MŠk(CZ) LO1204 Institutional support: RVO:61389030 Keywords : Aegilops markgrafii * Ae. triuncialis * Ae. cylindrica Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.982, year: 2015

  4. Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS

    Science.gov (United States)

    Boulyga, Sergei F.; Heumann, Klaus G.

    2005-04-01

    Laser ablation inductively coupled plasma isotope dilution mass spectrometry (LA-ICP-IDMS) with a special laser ablation system for bulk analyses (LINA-Spark(TM)-Atomiser) was applied for direct determinations of chlorine, bromine, and iodine in rock and sediment samples. Special attention was focused on possible inter-halogen fractionations and analyte/spike isotope fractionations by using LA-ICP-MS and LA-ICP-IDMS, respectively. A variation of Br/Cl and I/Cl element intensity ratios by a factor of 1.3-3 was observed when changing the nebulizer gas flow rate in the range of 0.84-1.0 L min-1 and the laser power density in the range of 2-10 GW cm-2, respectively. When using an internal standard for halogen quantification in LA-ICP-MS, this inter-element fractionation can cause systematic errors, which can be avoided by applying the isotope dilution technique. However, at high laser power densities (>5.7 GW cm-2 for iodine and >4.0 GW cm-2 for bromine and chlorine) the corresponding measured isotope ratio of the isotope-diluted sample deviates significantly from the target value. Under optimised conditions concentrations in the range of 30 [mu]g g-1-16 × 103 [mu]g g-1 for chlorine, <2-140 [mu]g g-1 for bromine, and <0.1-31 [mu]g g-1 for iodine were determined by LA-ICP-IDMS in two sediment reference materials (SRM 1646, SRM 2704) and three rock reference samples (GS-N, Granite; BX-N, Bauxite; DT-N, Disthene), which have not been certified for these halogens. The sediment results agree well within the given uncertainties with indicative values by different methods and the results of the rock samples with those obtained by negative thermal ionisation isotope dilution mass spectrometry. The detection limits of LA-ICP-IDMS are 8 [mu]g g-1 for chlorine, 1.7 [mu]g g-1 for bromine, and 0.1 [mu]g g-1 for iodine.

  5. Bioaccumulation of zinc in foodstuffs by nuclear and related techniques

    International Nuclear Information System (INIS)

    Diaz Rizo, O.; Olivares Reumont, S.; Lima Cazorla, L.; Gelen Rudnikas, A.; D'Alessandro Rodriguez, K.; Arado Lopez, J. O.; Denis Alpizar, O.; Diaz Arado, O.; Viguri Fuente, J.

    2011-01-01

    The bioaccumulation of zinc in regular consumption foodstuff (sugar, rice, some vegetables, roots and shellfishes) in Cuba is reported. Zinc content in food samples and its corresponding soils or sediments are determined by Instrumental Neutron Activation analysis (INAA), X-Ray Fluorescence analysis (XRF), inductively coupled plasma emission spectrometry (ICP-AES) and Atomic Absorption spectrometry (AES). The obtained results show rice as the major Zn bioaccumulator of the studied products and the main Zn source in Cuban human diet. (Author)

  6. AE Characteristics affecting the Notch Effect of the Cold Steel SKD11

    Energy Technology Data Exchange (ETDEWEB)

    Han, Eung Kyo; Kim, Ki Choong; Kwon, Dong Ho; Kim, Jae Yeor [Hanyang University, Seoul (Korea, Republic of)

    1986-11-15

    Acoustic Emission is not only expected as a non-destructive evaluation technique in practice but also noted as a new powerful means of evaluation of materials. AE occurs with plastic deformation and propagation of crack, and this patterns of occurrence of AE vary with materials. AE which comes from propagation of crack depends oil the shapes and properties of materials. Like this AE has characteristic of material. The present work is an attempt to evaluate characteristics of carbon steel (SM55C) and Die steel(SKD11) by means of dynamic response of AE method

  7. Complementary AES and AEM of grain boundary regions in irradiated γ'-strengthened alloys

    International Nuclear Information System (INIS)

    Farrell, K.; Kishimoto, N.; Clausing, R.E.; Heatherly, L.; Lehman, G.L.

    1986-01-01

    Two microchemical analysis techniques are used to measure solute segregation at grain boundaries in two γ'-strengthened, fcc Fe-Ni-Cr alloys that display radiation-induced intergranular fracture. Scanning Auger electron spectroscopy (AES) of grain boundary fracture surfaces and analytical electron microscopy (AEM) of intact grain boundaries using energy-dispersive x-ray spectroscopy show good agreement on the nature and extent of segregation. The elements Ni, Si, Ti, and Mo are found to accumulate in G, Laves and γ' phases on the grain boundaries. Segregation of P is detected by AES. The complementary features of the two analytical techniques are discussed briefly

  8. Heavy-metal contamination on training ranges at the Grafenwoehr Training Area, Germany

    Energy Technology Data Exchange (ETDEWEB)

    Zellmer, S.D.; Schneider, J.F.

    1993-05-01

    Large quantities of lead and other heavy metals are deposited in the environment of weapons ranges during training exercises. This study was conducted to determine the type, degree, and extent of heavy-metal contamination on selected handgun, rifle, and hand-grenade ranges at Grafenwoehr Training Area, Germany. Soil, vegetation, and surface-water samples were collected and analyzed using the inductively-coupled plasma atomic-emission spectroscopy (ICP-AES) method and the toxic characterization leaching procedure (TCLP). The ICP-AES results show that above-normal levels of lead and copper are in the surface soil at the handgun range, high concentrations of lead and copper are in the berm and soil surface at the rifle range, and elevated levels of cadmium and above-normal concentrations of arsenic, copper, and zinc are present in the surface soil at the hand-grenade range. The TCLP results show that surface soils can be considered hazardous waste because of lead content at the rifle range and because of cadmium concentration at the hand-grenade range. Vegetation at the handgun and rifle ranges has above-normal concentrations of lead. At the hand-grenade range, both vegetation and surface water have high levels of cadmium. A hand-held X-ray fluorescence (XRF) spectrum analyzer was used to measure lead concentrations in soils in a field test of the method. Comparison of XRF readings with ICP-AES results for lead indicate that the accuracy and precision of the hand-held XRF unit must improve before the unit can be used as more than a screening tool. Results of this study show that heavy-metal contamination at all three ranges is limited to the surface soil; heavy metals are not being leached into the soil profile or transported into adjacent areas.

  9. ICP experiments more durable pavements

    International Nuclear Information System (INIS)

    Carta Petrolera

    1994-01-01

    A new asphalts technology that will make more durable the pavement in the highways and roads of the cities of Colombia investigates the Colombian Institute of the Petroleum ICP. The project that will have important incidence in the solution of one of the main problems in the roads of cities like Bogota, is only one of the 35 investigation programs and application of new technologies that with relationship to the sector of the hydrocarbons and its influence branches the ICP advances. The investigation looks for to elevate the current average of useful life of the pavements, with that it would be reached a standard that has the developed countries in this field

  10. Monitoring total boron in blood for BNCT by a novel atomic emission method

    International Nuclear Information System (INIS)

    Laakso, J.; Kulvik, M.; Ruokonen, I.; Vaehaetalo, J.; Faerkkilae, M.; Kallio, M.; Zilliacus, R.

    2000-01-01

    In BNCT the duration and timing of the is adjusted by 10 B concentrations in whole blood. Time-frame for determinations is less than 20 minutes. Therefore fast and accurate boron determinations are a prerequisite for BNCT. We present a method based on ICP-AES instrument for whole blood and plasma boron determinations with protein precipitation with trichloroacetic acid as sample pre-treatment and beryllium as an internal standard. The method was compared to established but tedious ICP-mass spectrometric method with wet ashing as a sample pre-treatment. The ICP-AES method is in good agreement (correlation coefficient 0.99) the ICP-MS. Within-day and between-day imprecisions were less than 3,5% CV for whole blood samples. Samples taken during and after BPA-F infusion (290 mg/kg) revealed an uneven distribution between plasma and erythrocytes. The present method is feasible and one of the fastest currently available for BNCT. Our results indicate that BPA-F or its metabolites do not seem to be tightly bound to plasma proteins. It also seems that determination of boron in plasma sample may be preferable than measuring boron in whole blood. (author)

  11. Impaired STING Pathway in Human Osteosarcoma U2OS Cells Contributes to the Growth of ICP0-Null Mutant Herpes Simplex Virus.

    Science.gov (United States)

    Deschamps, Thibaut; Kalamvoki, Maria

    2017-05-01

    Human herpes simplex virus 1 (HSV-1) is a widespread pathogen, with 80% of the population being latently infected. To successfully evade the host, the virus has evolved strategies to counteract antiviral responses, including the gene-silencing and innate immunity machineries. The immediately early protein of the virus, infected cell protein 0 (ICP0), plays a central role in these processes. ICP0 blocks innate immunity, and one mechanism is by degrading hostile factors with its intrinsic E3 ligase activity. ICP0 also functions as a promiscuous transactivator, and it blocks repressor complexes to enable viral gene transcription. For these reasons, the growth of a ΔICP0 virus is impaired in most cells, except cells of the human osteosarcoma cell line U2OS, and it is only partially impaired in cells of the human osteosarcoma cell line Saos-2. We found that the two human osteosarcoma cell lines that supported the growth of the ΔICP0 virus failed to activate innate immune responses upon treatment with 2'3'-cyclic GAMP (2'3'-cGAMP), the natural agonist of STING (i.e., stimulator of interferon genes) or after infection with the ΔICP0 mutant virus. Innate immune responses were restored in these cells by transient expression of the STING protein but not after overexpression of interferon-inducible protein 16 (IFI16). Restoration of STING expression resulted in suppression of ΔICP0 virus gene expression and a decrease in viral yields. Overexpression of IFI16 also suppressed ΔICP0 virus gene expression, albeit to a lesser extent than STING. These data suggest that the susceptibility of U2OS and Saos-2 cells to the ΔICP0 HSV-1 is in part due to an impaired STING pathway. IMPORTANCE The DNA sensor STING plays pivotal role in controlling HSV-1 infection both in cell culture and in mice. The HSV-1 genome encodes numerous proteins that are dedicated to combat host antiviral responses. The immediate early protein of the virus ICP0 plays major role in this process as it targets

  12. Determination of stable isotope ratio of lead in airborne particulate matter by ICP-MS

    International Nuclear Information System (INIS)

    Mukai, Hitoshi; Ambe, Yoshinari

    1990-01-01

    ICP-MS was applied to the measurement of stable isotope ratios of lead, which are used as an indicator of the source of lead in airborne particulate matter. For the measurement of lead isotopes ratios, the influences of machine conditions, lead concentration and matrix elements to the precision and accuracy of the measurements were studied. At a scanning mode, dwell time of 40∼160 μs gave the best precision to the isotope ratio measurements; about 0.3 % of R.S.D. for 206 Pb/ 207 Pb and 206 Pb/ 208 Pb, 0.6 % for 206 Pb/ 204 Pb. Precision of the measurement was better at a high concentration of lead in sample solution. The observed value of 206 Pb/ 207 Pb ratio was not affected by the lead concentration, but in the cases of 206 Pb/ 204 Pb and 206 Pb/ 208 Pb, about 1 % of the value changed in the observed ratios with the lead concentration of 100∼500 μg/l. Six matrix elements (Na, K, Ca, Mg, Al, Fe) did not affect the observed isotope ratios up to 200 mg/l. The lead isotope ratios of reference materials {Urban Particulates (NIST) and Vehicle Exhausted Particulates (NIES)} were measured by using two kinds of sample; crude sample and lead-isolated sample from matrix elements by anodic deposition. Both cases gave the same isotope ratio values, therefore, lead isotope ratios in airborne particulate samples can be measured by ICP-MS without any separation of lead from matrix elements. (author)

  13. Repression of HNF1α-mediated transcription by amino-terminal enhancer of split (AES)

    Energy Technology Data Exchange (ETDEWEB)

    Han, Eun Hee [Section of Structural Biology, Hormel Institute, University of Minnesota, Austin, MN 55912 (United States); Gorman, Amanda A. [Department of Molecular and Cellular Biochemistry, University of Kentucky, Lexington, KY 40536 (United States); Singh, Puja [Section of Structural Biology, Hormel Institute, University of Minnesota, Austin, MN 55912 (United States); Chi, Young-In, E-mail: ychi@hi.umn.edu [Section of Structural Biology, Hormel Institute, University of Minnesota, Austin, MN 55912 (United States)

    2015-12-04

    HNF1α (Hepatocyte Nuclear Factor 1α) is one of the master regulators in pancreatic beta-cell development and function, and the mutations in Hnf1α are the most common monogenic causes of diabetes mellitus. As a member of the POU transcription factor family, HNF1α exerts its gene regulatory function through various molecular interactions; however, there is a paucity of knowledge in their functional complex formation. In this study, we identified the Groucho protein AES (Amino-terminal Enhancer of Split) as a HNF1α-specific physical binding partner and functional repressor of HNF1α-mediated transcription, which has a direct link to glucose-stimulated insulin secretion in beta-cells that is impaired in the HNF1α mutation-driven diabetes. - Highlights: • We identified AES as a transcriptional repressor for HNF1α in pancreatic beta-cell. • AES's repressive activity was HNF1α-specific and was not observed with HNF1β. • AES interacts with the transactivation domain of HNF1α. • Small molecules can be designed or discovered to disrupt this interaction and improve insulin secretion and glucose homeostasis.

  14. Repression of HNF1α-mediated transcription by amino-terminal enhancer of split (AES)

    International Nuclear Information System (INIS)

    Han, Eun Hee; Gorman, Amanda A.; Singh, Puja; Chi, Young-In

    2015-01-01

    HNF1α (Hepatocyte Nuclear Factor 1α) is one of the master regulators in pancreatic beta-cell development and function, and the mutations in Hnf1α are the most common monogenic causes of diabetes mellitus. As a member of the POU transcription factor family, HNF1α exerts its gene regulatory function through various molecular interactions; however, there is a paucity of knowledge in their functional complex formation. In this study, we identified the Groucho protein AES (Amino-terminal Enhancer of Split) as a HNF1α-specific physical binding partner and functional repressor of HNF1α-mediated transcription, which has a direct link to glucose-stimulated insulin secretion in beta-cells that is impaired in the HNF1α mutation-driven diabetes. - Highlights: • We identified AES as a transcriptional repressor for HNF1α in pancreatic beta-cell. • AES's repressive activity was HNF1α-specific and was not observed with HNF1β. • AES interacts with the transactivation domain of HNF1α. • Small molecules can be designed or discovered to disrupt this interaction and improve insulin secretion and glucose homeostasis.

  15. Analysis of plutonium isotope ratios including 238Pu/239Pu in individual U-Pu mixed oxide particles by means of a combination of alpha spectrometry and ICP-MS.

    Science.gov (United States)

    Esaka, Fumitaka; Yasuda, Kenichiro; Suzuki, Daisuke; Miyamoto, Yutaka; Magara, Masaaki

    2017-04-01

    Isotope ratio analysis of individual uranium-plutonium (U-Pu) mixed oxide particles contained within environmental samples taken from nuclear facilities is proving to be increasingly important in the field of nuclear safeguards. However, isobaric interferences, such as 238 U with 238 Pu and 241 Am with 241 Pu, make it difficult to determine plutonium isotope ratios in mass spectrometric measurements. In the present study, the isotope ratios of 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu were measured for individual Pu and U-Pu mixed oxide particles by a combination of alpha spectrometry and inductively coupled plasma mass spectrometry (ICP-MS). As a consequence, we were able to determine the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu isotope ratios with ICP-MS after particle dissolution and chemical separation of plutonium with UTEVA resins. Furthermore, 238 Pu/ 239 Pu isotope ratios were able to be calculated by using both the 238 Pu/( 239 Pu+ 240 Pu) activity ratios that had been measured through alpha spectrometry and the 240 Pu/ 239 Pu isotope ratios determined through ICP-MS. Therefore, the combined use of alpha spectrometry and ICP-MS is useful in determining plutonium isotope ratios, including 238 Pu/ 239 Pu, in individual U-Pu mixed oxide particles. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Identification of a novel higher molecular weight isoform of USP7/HAUSP that interacts with the Herpes simplex virus type-1 immediate early protein ICP0.

    Science.gov (United States)

    Antrobus, Robin; Boutell, Chris

    2008-10-01

    The Herpes simplex virus type-1 (HSV-1) regulatory protein ICP0, a RING-finger E3 ubiquitin ligase, stimulates the onset of viral lytic replication and the reactivation of quiescent viral genomes from latency. Like many ubiquitin ligases ICP0 induces its own ubiquitination, a process that can lead to its proteasome-dependent degradation. ICP0 counteracts this activity by recruiting the cellular ubiquitin-specific protease USP7/HAUSP. Here we show that ICP0 can also interact with a previously unidentified isoform of USP7 (termed here USP7(beta)). This isoform is not a predominantly ubiquitinated, SUMO-modified, or phosphorylated species of USP7 but is constitutively expressed in a number of different cell types. Like USP7, USP7(beta) binds specifically to an electrophilic ubiquitin probe, indicating that it contains an accessible catalytic core with potential ubiquitin-protease activity. The interaction formed between ICP0 and USP7(beta) requires ICP0 to have an intact USP7-binding domain and results in its susceptibility to ICP0-mediated degradation during HSV-1 infection.

  17. AE/VCE Unconfirmed Vernal Pools

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset is derived from a project by the Vermont Center for Ecostudies(VCE) and Arrowwood Environmental(AE) to map vernal pools throughout the state of Vermont....

  18. AE/VCE Confirmed Vernal Pools

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset is derived from a project by the Vermont Center for Ecostudies(VCE) and Arrowwood Environmental(AE) to map vernal pools throughout the state of Vermont....

  19. Realization and optimization of AES algorithm on the TMS320DM6446 based on DaVinci technology

    Science.gov (United States)

    Jia, Wen-bin; Xiao, Fu-hai

    2013-03-01

    The application of AES algorithm in the digital cinema system avoids video data to be illegal theft or malicious tampering, and solves its security problems. At the same time, in order to meet the requirements of the real-time, scene and transparent encryption of high-speed data streams of audio and video in the information security field, through the in-depth analysis of AES algorithm principle, based on the hardware platform of TMS320DM6446, with the software framework structure of DaVinci, this paper proposes the specific realization methods of AES algorithm in digital video system and its optimization solutions. The test results show digital movies encrypted by AES128 can not play normally, which ensures the security of digital movies. Through the comparison of the performance of AES128 algorithm before optimization and after, the correctness and validity of improved algorithm is verified.

  20. Development of a protocol to measure iron-55 in solid matrices in the environment

    International Nuclear Information System (INIS)

    Augeray, Céline; Magalie, Mouton; Nathalie, Broustet; Marie-France, Perdereau; Chloé, Laconici; Jeanne, Loyen; Corinne, Fayolle; Jean-Louis, Picolo

    2015-01-01

    The development of metrology of iron-55 in low-level radioactivity in environmental solid matrices was realised for conducting radioecological studies. A protocol was developed based on the adaptation of existing methods for the purification of iron-55 with selective chromatographic resin, which was then measured with liquid scintillation. The loss attached treatment chemical steps were quantified with elemental iron by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The tests were used to define the iron retention capacity of selective chromatographic resin, a key element in chemical treatment, and test sample size needed to reach the detection limit of 30 Bq kg −1  dry. The solid samples were analysed with the developed protocol. The activities obtained from iron-55 were below the detection limit of 30 Bq kg −1  dry. - Highlights: • To obtain the desired detection limit in environmental solid matrices, the choice of method was realised. • A protocol was thus developed with our resources to obtain a 30 Bq kg-1 dry detection limit. • The optimisation of the operating conditions is described and the activities obtained are presented

  1. An AES chip with DPA resistance using hardware-based random order execution

    International Nuclear Information System (INIS)

    Yu Bo; Li Xiangyu; Chen Cong; Sun Yihe; Wu Liji; Zhang Xiangmin

    2012-01-01

    This paper presents an AES (advanced encryption standard) chip that combats differential power analysis (DPA) side-channel attack through hardware-based random order execution. Both decryption and encryption procedures of an AES are implemented on the chip. A fine-grained dataflow architecture is proposed, which dynamically exploits intrinsic byte-level independence in the algorithm. A novel circuit called an HMF (Hold-Match-Fetch) unit is proposed for random control, which randomly sets execution orders for concurrent operations. The AES chip was manufactured in SMIC 0.18 μm technology. The average energy for encrypting one group of plain texts (128 bits secrete keys) is 19 nJ. The core area is 0.43 mm 2 . A sophisticated experimental setup was built to test the DPA resistance. Measurement-based experimental results show that one byte of a secret key cannot be disclosed from our chip under random mode after 64000 power traces were used in the DPA attack. Compared with the corresponding fixed order execution, the hardware based random order execution is improved by at least 21 times the DPA resistance. (semiconductor integrated circuits)

  2. An AES chip with DPA resistance using hardware-based random order execution

    Science.gov (United States)

    Bo, Yu; Xiangyu, Li; Cong, Chen; Yihe, Sun; Liji, Wu; Xiangmin, Zhang

    2012-06-01

    This paper presents an AES (advanced encryption standard) chip that combats differential power analysis (DPA) side-channel attack through hardware-based random order execution. Both decryption and encryption procedures of an AES are implemented on the chip. A fine-grained dataflow architecture is proposed, which dynamically exploits intrinsic byte-level independence in the algorithm. A novel circuit called an HMF (Hold-Match-Fetch) unit is proposed for random control, which randomly sets execution orders for concurrent operations. The AES chip was manufactured in SMIC 0.18 μm technology. The average energy for encrypting one group of plain texts (128 bits secrete keys) is 19 nJ. The core area is 0.43 mm2. A sophisticated experimental setup was built to test the DPA resistance. Measurement-based experimental results show that one byte of a secret key cannot be disclosed from our chip under random mode after 64000 power traces were used in the DPA attack. Compared with the corresponding fixed order execution, the hardware based random order execution is improved by at least 21 times the DPA resistance.

  3. Interference-free determination of sub ng kg-1 levels of long-lived 93Zr in the presence of high concentrations (μg kg-1) of 93Mo and 93Nb using ICP-MS/MS.

    Science.gov (United States)

    Petrov, Panayot; Russell, Ben; Douglas, David N; Goenaga-Infante, Heidi

    2018-01-01

    Long-lived high abundance radionuclides are of increasing interest with regard to decommissioning of nuclear sites and longer term nuclear waste storage and disposal. In many cases, no routine technique is available for their measurement in nuclear waste and low-level (ng kg -1 ) environmental samples. Recent advances in ICP-MS technology offer attractive features for the selective and sensitive determination of a wide range of long-lived radionuclides. In this work, inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS)-based methodology, suitable for accurate routine determinations of 93 Zr at very low (ng kg -1 ) levels in the presence of high levels (μg kg -1 ) of the isobaric interferents 93 Nb and 93 Mo (often present in nuclear waste samples), is reported for the first time. Additionally, a novel and systematic strategy for method development based on the use of non-radioactive isotopes is proposed. It relies on gas-phase chemical reactions for different molecular ion formation to achieve isobaric interference removal. Using cell gas mixtures of NH 3 /He/H 2 or H 2 /O 2 , and suitable mass shifts, the signal from the 93 Nb and 93 Mo isobaric interferences on 93 Zr were suppressed by up to 5 orders of magnitude. The achieved limit of detection for 93 Zr was 1.3 × 10 -5  Bq g -1 (equivalent to 0.14 ng kg -1 ). The sample analysis time is 2 min, which represents a significant improvement in terms of sample throughput, compared to liquid scintillation counting methods. The method described here can be used for routine measurements of 93 Zr at environmentally relevant levels. It can also be combined with radiometric techniques for use towards the standardisation of 93 Zr measurements. Graphical abstract Interference-free determination of 93 Zr in the presence of high concentrations of isobaric 93 Mo and 93 Nb by ICP-MS/MS.

  4. Synthesis and structural characterization of the ternary Zintl phases AE3Al2Pn4 and AE3Ga2Pn4 (AE=Ca, Sr, Ba, Eu; Pn=P, As)

    International Nuclear Information System (INIS)

    He, Hua; Tyson, Chauntae; Saito, Maia; Bobev, Svilen

    2012-01-01

    Ten new ternary phosphides and arsenides with empirical formulae AE 3 Al 2 Pn 4 and AE 3 Ga 2 Pn 4 (AE=Ca, Sr, Ba, Eu; Pn=P, As) have been synthesized using molten Ga, Al, and Pb fluxes. They have been structurally characterized by single-crystal and powder X-ray diffraction to form with two different structures—Ca 3 Al 2 P 4 , Sr 3 Al 2 As 4 , Eu 3 Al 2 P 4 , Eu 3 Al 2 As 4 , Ca 3 Ga 2 P 4 , Sr 3 Ga 2 P 4 , Sr 3 Ga 2 As 4 , and Eu 3 Ga 2 As 4 crystallize with the Ca 3 Al 2 As 4 structure type (space group C2/c, Z=4); Ba 3 Al 2 P 4 and Ba 3 Al 2 As 4 adopt the Na 3 Fe 2 S 4 structure type (space group Pnma, Z=4). The polyanions in both structures are made up of TrPn 4 tetrahedra, which share common corners and edges to form 2 ∞ [TrPn 2 ] 3– layers in the phases with the Ca 3 Al 2 As 4 structure, and 1 ∞ [TrPn 2 ] 3– chains in Ba 3 Al 2 P 4 and Ba 3 Al 2 As 4 with the Na 3 Fe 2 S 4 structure type. The valence electron count for all of these compounds follows the Zintl–Klemm rules. Electronic band structure calculations confirm them to be semiconductors. - Graphical abstract: AE 3 Al 2 Pn 4 and AE 3 Ga 2 Pn 4 (AE=Ca, Sr, Ba, Eu; Pn=P, As) crystallize in two different structures—Ca 3 Al 2 P 4 , Sr 3 Al 2 As 4 , Eu 3 Al 2 P 4 , Eu 3 Al 2 As 4 , Ca 3 Ga 2 P 4 , Sr 3 Ga 2 P 4 , Sr 3 Ga 2 As 4 , and Eu 3 Ga 2 As 4 , are isotypic with the previously reported Ca 3 Al 2 As 4 (space group C2/c (No. 15)), while Ba 3 Al 2 P 4 and Ba 3 Al 2 As 4 adopt a different structure known for Na 3 Fe 2 S 4 (space group Pnma (No. 62). The polyanions in both structures are made up of TrPn 4 tetrahedra, which by sharing common corners and edges, form 2 ∞ [TrPn 2 ] 3– layers in the former and 1 ∞ [TrPn 2 ] 3– chains in Ba 3 Al 2 P 4 and Ba 3 Al 2 As 4 . Highlights: ► AE 3 Ga 2 Pn 4 (AE=Ca, Sr, Ba, Eu; Pn=P, As) are new ternary pnictides. ► Ba 3 Al 2 P 4 and Ba 3 Al 2 As 4 adopt the Na 3 Fe 2 S 4 structure type. ► The Sr- and Ca-compounds crystallize with the Ca 3

  5. Comparative evaluation of ICP sample introduction systems to be used in the metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS.

    Science.gov (United States)

    Klencsár, Balázs; Sánchez, Carlos; Balcaen, Lieve; Todolí, José; Lynen, Frederic; Vanhaecke, Frank

    2018-05-10

    A systematic evaluation of four different ICP sample introduction systems to be used in the context of metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS was carried out using diclofenac and its major metabolite, 4'-hydroxy-diclofenac, as model compounds. The strict requirements for GMP validation of chromatographic methods in the pharmaceutical industry were adhered to in this context. The final aim of this investigation is an extension of the applicability and validatability of HPLC-ICP-MS in the field of pharmaceutical R&D. Five different gradient programmes were tested while the baseline peak width (w b ), peak capacity (P), USP tailing factor (A s ) and USP signal-to-noise ratio (USP S/N) were determined as major indicators of the chromatographic performance and the values obtained were compared to the corresponding FDA recommendations (if applicable). Four different ICP-MS sample introductions systems were investigated involving two units typically working at higher flow rates (∼1.0 mL min -1 ) and another two systems working at lower flow rates (∼0.1 mL min -1 ). Optimal conditions with potential for applicability under GMP conditions were found at a mobile phase flow rate of 1.0 mL min -1 by using a pneumatic micro-flow LC nebulizer mounted onto a Peltier-cooled cyclonic spray chamber cooled to -1 °C for sample introduction. Under these conditions, HPLC-ICP-MS provided a chromatographic performance similar to that of HPLC with UV detection. The peak shape (USP tailing factor = 1.1-1.4) was significantly improved compared to that obtained with the Peltier-cooled Scott-type spray chamber. Two alternative sample introduction systems - a POINT ® and a High-Temperature Torch-Integrated Sample Introduction System (hTISIS) - were also tested at a flow rate of 0.1 mL min -1 using a chromatographic column with 1.0 mm ID. Although these systems allowed the peak shape to be improved compared to that obtained with

  6. The influence of laser pulse duration and energy on ICP-MS signal intensity, elemental fractionation, and particle size distribution in NIR fs-LA-ICP-MS

    Science.gov (United States)

    Diwakar, Prasoon K.; Harilal, Sivanandan S.; LaHaye, Nicole L.; Hassanein, Ahmed; Kulkarni, Pramod

    2015-01-01

    Laser parameters, typically wavelength, pulse width, irradiance, repetition rate, and pulse energy, are critical parameters which influence the laser ablation process and thereby influence the LA-ICP-MS signal. In recent times, femtosecond laser ablation has gained popularity owing to the reduction in fractionation related issues and improved analytical performance which can provide matrix-independent sampling. The advantage offered by fs-LA is due to shorter pulse duration of the laser as compared to the phonon relaxation time and heat diffusion time. Hence the thermal effects are minimized in fs-LA. Recently, fs-LA-ICP-MS demonstrated improved analytical performance as compared to ns-LA-ICP-MS, but detailed mechanisms and processes are still not clearly understood. Improvement of fs-LA-ICP-MS over ns-LA-ICP-MS elucidates the importance of laser pulse duration and related effects on the ablation process. In this study, we have investigated the influence of laser pulse width (40 fs to 0.3 ns) and energy on LA-ICP-MS signal intensity and repeatability using a brass sample. Experiments were performed in single spot ablation mode as well as rastering ablation mode to monitor the Cu/Zn ratio. The recorded ICP-MS signal was correlated with total particle counts generated during laser ablation as well as particle size distribution. Our results show the importance of pulse width effects in the fs regime that becomes more pronounced when moving from femtosecond to picosecond and nanosecond regimes. PMID:26664120

  7. Novel fast-neutron activation counter for high repetition rate measurements

    International Nuclear Information System (INIS)

    Mahmood, S.; Springham, S. V.; Zhang, T.; Rawat, R. S.; Tan, T. L.; Krishnan, M.; Beg, F. N.; Lee, S.; Schmidt, H.; Lee, P.

    2006-01-01

    A fast-neutron beryllium activation counter has been constructed for neutron measurements on a high repetition rate deuterium plasma focus. Beryllium activation is especially suitable for measurements of DD neutron yields. The cross section for the relevant reaction, 9 Be(n,α) 6 He, results in a maximum sensitivity at the characteristic energy of the DD neutrons (∼2.5 MeV) and practically no sensitivity to neutrons with energies 6 He enabled the shot-to-shot neutron yield from the plasma focus to be measured for repetition rates from 0.2 to 3 Hz (and for a range of deuterium gas pressures). With careful analysis, the shot-to-shot yield can be measured up to a maximum repetition rate of 3 Hz, beyond which the pileup of counts from the previous shots reduces the accuracy of the measurements to an unacceptable level. This new beryllium activation counter has been cross-checked against an indium activation counter to obtain absolute neutron yields. At a charging voltage of 12.5 kV (bank energy of 2.2 kJ), the average neutron yield was found to be (7.9±0.7)x10 7 per shot (standard deviation of 4x10 7 ). It was found that activation of the plasma focus construction materials (especially aluminum) must be taken into account

  8. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F.; Heilmann, Jens; Heumann, Klaus G. [Johannes Gutenberg-University Mainz (Germany). Institute of Inorganic Chemistry and Analytical Chemistry

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different {sup 34}S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured {sup 34}S/{sup 32}S isotope ratio of the isotope-diluted sample remained constant - a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 {mu}g g{sup -1} ('sulfur-free' premium gasoline) to 10.4 mg g{sup -1} (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 {mu}g g{sup -1} and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level. (orig.)

  9. Are Polyatomic Interferences, Cross Contamination, Mixing-Effect, etc., Obstacles for the Use of Laser Ablation-ICP-MS Coupling as an Operational Technique for Uranium Isotope Ratio Particle Analysis?

    International Nuclear Information System (INIS)

    Donard, A.; Pointurier, F.; Pecheyran, C.

    2015-01-01

    Analysis of ''environmental samples'', which consists in dust collected with cotton clothes wiped by inspectors on surfaces inside declared nuclear facilities, is a key tool for safeguards. Although two methods (fission tracks-TIMS and SIMS) are already used routinely to determine the isotopic composition of uranium particles, the laser ablationinductively coupled plasma mass spectrometry (LA-ICP-MS) coupling has been proven to be an interesting option thanks to its rapidity, high sensitivity and high signal/noise ratio. At CEA and UPPA, feasibility of particle analysis using a nanosecond LA device and a quadrupole ICP-MS has been demonstrated. However, despite the obvious potential of LA-ICP-MS for particle analysis, the effect of many phenomena which may bias isotope ratio measurements or lead to false detections must be investigated. Actually, environmental samples contain many types of non-uranium particles (organic debris, iron oxides, etc.) that can form molecular interferences and induce the risk of isotopic measurement bias, especially for minor isotopes (234U, 236U). The influence of these polyatomic interferences on the measurements will be discussed. Moreover, different uranium isotopic compositions can be found in the same sample. Therefore, risks of memory effect and of particle-toparticle cross-contamination by the deposition of ablation debris around the crater have also been investigated. This study has been conducted by using a femtosecond laser ablation device coupled to a high sensitivity sector field ICP-MS. Particles were fixed onto the discs with collodion and were located thanks to their fission tracks so that micrometric particles can be analyzed separately. All uranium isotope ratios were measured. Results are compared with the ones obtained with the fission tracks-TIMS technique on other deposition discs from the same sample. Performance of the method in terms of accuracy, precision, and detection limits are estimated

  10. Determination 230Th by ICP-MS for the control of activities of restoration of an area of land contaminated with uranium mining sterile

    International Nuclear Information System (INIS)

    Yague, L.; Conde, E.; Navarro, N.; Fernandez, M.; Ortiz, M. I.; Noguerales, C.; Gasco, C.

    2013-01-01

    In 2012, within the activities for the Project PIMIC (CIEMAT) took out the first stage of restoration of a contaminated area. This is an area which had a residual contamination due to burial tailings uranium mining. The activities have been: elimination of the arboreal mass, excavation of the ground and earthmoving. The methodology applied is described in this work and is based on the combination of gamma spectrometry technique and development of a method of analysis 230 Th by ICP-MS. (Author)

  11. ICP-MS Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Carman, April J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eiden, Gregory C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-11-01

    This is a short document that explains the materials that will be transmitted to LLNL and DNN HQ regarding the ICP-MS Workshop held at PNNL June 17-19th. The goal of the information is to pass on to LLNL information regarding the planning and preparations for the Workshop at PNNL in preparation of the SIMS workshop at LLNL.

  12. Investigation of polyelectrolytes by total reflection x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Varga, I.; Nagy, M.

    2000-01-01

    Water soluble polyelectrolyte samples containing mono-, bi- and trivalent metal ions were investigated without any pretreatment. Acid digestion of linear polymers may lead to a product insoluble in water so the digestion has to be avoided. The aim of this paper was the determination of analytical characteristics and limitations of the total reflection x-ray fluorescence (TXRF) analysis for poly (vinylalcohol-vinylsulphate) salts and poly (acrylic acid, acrylamide) copolymers containing the following cations: K + , Cs + , Ba 2+ , Cu 2+ and La 3+ . On the basis of our results efficiency of ion-exchange during preparation of polyelectrolytes and stoichiometry of the end-product were determined. TXRF results were compared with data gained by inductively coupled plasma atomic emission spectrometry (ICP-AES) measurements except in the case of Cs + which has poor sensitivity in ICP-AES. Good agreement was found between the results of the two techniques and calculations from titrimetric data. Concentration of Li + and Mg 2+ in polymer samples was measured by ICP-AES. In majority of cases film-like dry residues of aqueous solutions of polyelectrolytes can be characterized by homogeneous spatial distribution of metal ions within the organic matrix. This is because the migration of the ions is hindered during drying process. Determination of metals in polyelectrolyte films by TXRF is quite ideal as model for analysis of plant, animal or human tissues which is a frequent task in environmental and inorganic biomedical analytical chemistry. (author)

  13. Experience with NAA and radionuclides in an industrial laboratory

    International Nuclear Information System (INIS)

    Bossus, D.A.W.; Sluijs, R. van

    1998-01-01

    Radioisotopes have been used in a wide variety of industrial applications since the early 1950s. At DSM, a Dutch chemicals and materials group, the first applications were introduced around 1955. These applications mainly concerned on-line density measurements for process-control purposes. Besides process control, the following main applications of radioisotopes can be distinguished: (i) Column scanning: a technique using sealed 60 Co, 137 Cs and 252 Cf sources for on-line troubleshooting in distillation columns and other process equipment; this technique allows investigations to be performed at very short notice, saving production time and therefore money. (ii) The radiotracer technique: used as a tool for troubleshooting, for flow measurements, for determining process parameters and for in-line corrosion studies. Short-lived radionuclides typically used in this field are 56Mn, 24Na, 82Br, 113mIn, 81mKr and 99mTc; (iii) Neutron activation analysis based on the k 0 -standardization method. The NAA technique, which was originally introduced for trace element analysis in high-purity silica, has evolved into a key analytical technique at DSM Research besides ICP-MS, ICP-AES and other sophisticated in-house methods

  14. Study on Huizhou architecture of point cloud registration based on optimized ICP algorithm

    Science.gov (United States)

    Zhang, Runmei; Wu, Yulu; Zhang, Guangbin; Zhou, Wei; Tao, Yuqian

    2018-03-01

    In view of the current point cloud registration software has high hardware requirements, heavy workload and moltiple interactive definition, the source of software with better processing effect is not open, a two--step registration method based on normal vector distribution feature and coarse feature based iterative closest point (ICP) algorithm is proposed in this paper. This method combines fast point feature histogram (FPFH) algorithm, define the adjacency region of point cloud and the calculation model of the distribution of normal vectors, setting up the local coordinate system for each key point, and obtaining the transformation matrix to finish rough registration, the rough registration results of two stations are accurately registered by using the ICP algorithm. Experimental results show that, compared with the traditional ICP algorithm, the method used in this paper has obvious time and precision advantages for large amount of point clouds.

  15. Measurement of strontium isotope ratio in nitric acid extract of peanut testa by ICP-Q-MS after removal of Rb by extraction with pure water.

    Science.gov (United States)

    Zhu, Yanbei; Hioki, Akiharu; Chiba, Koichi

    2014-02-01

    The difference in the distributions of Sr and Rb in peanut seeds was utilized to develop a precise method for Sr isotope ratio measurement by inductively coupled plasma quadruple mass spectrometry (ICP-Q-MS). The testa instead of the whole peanut seed was selected as the sample because apparent enrichment of Sr in comparison to Rb was found in the testa. Furthermore, Rb in the testa was removed by pure water extraction with the aid of sonication to remove the isobaric interference in Sr isotope ratio measurement. The testa taken from one peanut seed was treated as one sample for the analysis. After optimization of the operating conditions, pure water (10 mL for each sample) extraction in 30 min with sonication was able to remove over 95% of Rb in the testa, while after the Rb removal Sr could be completely extracted using 10 mL of 0.3 mol L(-1) HNO3 for each sample. The integration time in ICP-Q-MS measurement was optimized to achieve a lower measurement uncertainty in a shorter time; the results showed that 1s was required and enough for the precise measurement of Sr isotope ratios giving a relative standard uncertainty (n=10) of ca. 0.1%. The present method was applied to peanut seeds grown in Japan, China, USA, India, and South Africa. © 2013 Published by Elsevier B.V.

  16. Hello darkness my old friend: the fading of the nearby TDE ASASSN-14ae

    Science.gov (United States)

    Brown, Jonathan S.; Shappee, Benjamin J.; Holoien, T. W.-S.; Stanek, K. Z.; Kochanek, C. S.; Prieto, J. L.

    2016-11-01

    We present late-time optical spectroscopy taken with the Large Binocular Telescope's Multi-Object Double Spectrograph, an improved All-Sky Automated Survey for SuperNovae pre-discovery non-detection, and late-time Swift observations of the nearby (d = 193 Mpc, z = 0.0436) tidal disruption event (TDE) ASASSN-14ae. Our observations span from ˜20 d before to ˜750 d after discovery. The proximity of ASASSN-14ae allows us to study the optical evolution of the flare and the transition to a host-dominated state with exceptionally high precision. We measure very weak Hα emission 300 d after discovery (LH α ≃ 4 × 1039 erg s-1) and the most stringent upper limit to date on the Hα luminosity ˜750 d after discovery (LH α ≲ 1039 erg s-1), suggesting that the optical emission arising from a TDE can vanish on a time-scale as short as 1 yr. Our results have important implications for both spectroscopic detection of TDE candidates at late times, as well as the nature of TDE host galaxies themselves.

  17. Investigation of reordered (001) Au surfaces by positive ion channeling spectroscopy, LEED and AES

    International Nuclear Information System (INIS)

    Appleton, B.R.; Noggle, T.S.; Miller, J.W.; Schow, O.E. III; Zehner, D.M.; Jenkins, L.H.; Barrett, J.H.

    1974-01-01

    As a consequence of the channeling phenomenon of positive ions in single crystals, the yield of ions Rutherford scattered from an oriented single crystal surface is dependent on the density of surface atoms exposed to the incident ion beam. Thus, the positive ion channeling spectroscopy (PICS) technique should provide a useful tool for studying reordered surfaces. This possibility was explored by examining the surfaces of epitaxially grown thin Au single crystals with the combined techniques of LEED-AES and PICS. The LEED and AES investigations showed that when the (001) surface was sputter cleaned in ultra-high vacuum, the normal (1 x 1) symmetry of the (001) surfaces reordered into a structure which gave a complex (5 x 20) LEED pattern. The yield and energy distributions of 1 MeV He ions scattered from the Au surfaces were used to determine the number of effective monolayers contributing to the normal and reordered surfaces. These combined measurements were used to characterize the nature of the reordered surface. The general applicability of the PICS technique for investigations of surface and near surface regions is discussed

  18. Combination of multielement technique (INAA and ICP-MS) for a French air pollution bio-monitoring survey using mosses

    International Nuclear Information System (INIS)

    Ayrault, S.; Deschamps, C.; Amblard, G.; Galsomies, L.; Letrouit-Galinou, M.A.; Bonhomme, P.

    1998-01-01

    This work presents the use of two trace analysis techniques through the data obtained for a significant part of the 557 mosses sampled in France. Sampling were made within the framework of European survey carried out in 1995-1996 and proposed by the Nordic Council. The analyses were produced with a combination of two multielement analysis techniques: INAA (Instrumental Neutron Activation Analysis) and ICP-MS (Inductively Coupled Plasma Mass Spectrometry). Theses two techniques were suitable for trace analyses in mosses. They were clearly complementary and provided for 36 elements including the heavy metals of key interest in air pollution studies. The choice of the technique for a given element depended on the feasibility (e g. Pb is not attainable by INAA), the detection limit, the analytical variability, the preparation procedures and the concentration ranges (5-100 μg/g for Pb, 0.5-5 μg/g for As). INAA measured the total content in the sample, while ICP-MS demanded a mineralization procedure resulting in losses/contamination hazards. Thus, INAA results were preferred, although this technique was time consuming. However the ICP-MS results for Cd, Cu, Ni and Pb were retained, for different reasons: detection limits (Cd, Cu), no convenient INAA conditions (Ni), and feasibility (Pb). (authors)

  19. Integrated interpretation of AE clusters and fracture system in Hijiori HDR artificial reservoir; Hijiori koon gantai jinko choryuso no AE cluster to kiretsu system ni kansuru togoteki kaishaku

    Energy Technology Data Exchange (ETDEWEB)

    Tezuka, K [Japan Petroleum Exploration Corp., Tokyo (Japan); Niitsuma, H [Tohoku University, Sendai (Japan)

    1997-05-27

    With regard to a fracture system in the Hijiori hot dry rock artificial reservoir, an attempt was made on an interpretation which integrates different data. Major factors that characterize development and performance of an artificial reservoir are composed of a fracture system in rocks, which acts as circulating water paths, a heat exchange face and a reservoir space. The system relates not only with crack density distribution, but also with cracks activated by water pressure fracturing, cracks generating acoustic emission (AE), and cracks working as major flow paths, all of which are characterized by having respective behaviors and roles. Characteristics are shown on AE cluster distribution, crack distribution, production zone and estimated stress fields. Mutual relationship among these elements was discussed based on the Coulomb`s theory. The most important paths are characterized by distribution of slippery cracks. Directions and appearance frequencies of the slippery cracks affect strongly directionality of the paths, which are governed by distribution of the cracks (weak face) and stress field. Among the slippery cracks, cracks that generate AE are cracks that release large energy when a slip occurs. Evaluation on slippery crack distribution is important. 7 refs., 8 figs.

  20. Separation of Pu from soil prior to determination by ICP-MS

    International Nuclear Information System (INIS)

    Nygren, U.; Baxter, D.C.

    2002-01-01

    In the determination of plutonium in environmental materials by ICP-MS, chemical separation is often needed to remove, e.g., heavy sample matrices and interference from UH + on m/z 239. This separation can be, and often is, performed in the same way as for alpha-spectrometric analysis. There are, however, somewhat different demands on separation for ICP-MS compared to alpha-spectrometry, but so far little has been published on the optimisation of separation procedures for plutonium determination by ICP-MS. This paper describes the development of a separation procedure especially suited for the determination of Pu by ICP-MS. Focus has been on parameters such as chemical yield of plutonium and decontamination from uranium, as well as time requirements and ease of performance. The separation of plutonium was performed using various resins, such as anion exchange resin and extraction chromatographic materials. The procedures were carried out on water spiked with 238 U and 240 Pu to concentrations of approximately 300 ppb and 50 ppt, respectively. The basic separation procedure was: 1. Adjustment of oxidation state for Pu 2. Loading on column 3. Rinsing using 4*5 free column volumes (FCVs) of load solution - if needed in combination with 1*5 FCVs of an other rinsing agent 4. Elution of Pu - if needed followed by evaporation and dissolution in a solution suitable for ICP-MS determination 5. Determination by high resolution ICP-MS The elution of plutonium was performed using various media, based on either reduction of Pu(IV) to Pu(III) or complex formation. The chemical yield of plutonium and the decontamination from uranium for various resin/elution combinations can be seen in Figs. 1 and 2. It was found that the most efficient separation procedure in terms of yield and uranium decontamination was the combination of two extraction chromatographic materials, UTEVA followed by TRU, and elution of Pu by 0.1 % 1-hydroxyethane-1,1-diphosphonic acid (HEDPA). In this procedure

  1. Wireless AE Event and Environmental Monitoring for Wind Turbine Blades at Low Sampling Rates

    Science.gov (United States)

    Bouzid, Omar M.; Tian, Gui Y.; Cumanan, K.; Neasham, J.

    Integration of acoustic wireless technology in structural health monitoring (SHM) applications introduces new challenges due to requirements of high sampling rates, additional communication bandwidth, memory space, and power resources. In order to circumvent these challenges, this chapter proposes a novel solution through building a wireless SHM technique in conjunction with acoustic emission (AE) with field deployment on the structure of a wind turbine. This solution requires a low sampling rate which is lower than the Nyquist rate. In addition, features extracted from aliased AE signals instead of reconstructing the original signals on-board the wireless nodes are exploited to monitor AE events, such as wind, rain, strong hail, and bird strike in different environmental conditions in conjunction with artificial AE sources. Time feature extraction algorithm, in addition to the principal component analysis (PCA) method, is used to extract and classify the relevant information, which in turn is used to classify or recognise a testing condition that is represented by the response signals. This proposed novel technique yields a significant data reduction during the monitoring process of wind turbine blades.

  2. Radionuclide content of simulated and fully radioactive SRLLL waste glasses: comparison of results from ICP-MS, gamma spectrometry and alpha spectrometry

    International Nuclear Information System (INIS)

    Wolf, S.F.; Bates, J.K.

    1995-01-01

    We have measured the transuranic content of two transuranic=doped, simulated waste glasses, using inductively coupled plasma-mass spectrometry (ICP-MS), γ-spectrometry, and α-spectrometry. Average concentrations measured by each technique were within ± 10% of the as-doped concentrations. We also report the transuranic content of three fully radioactive SRL waste glasses that were determined using γ- and α-spectrometry measurements to deconvolute isobaric interferences present in the ICP-MS analyses

  3. Synthesis and in vivo evaluation of carborane gadolinium-DTPA complex as an MR imaging boron carrier

    International Nuclear Information System (INIS)

    Nakamura, H.; Fukuda, H.; Girald, F.

    2000-01-01

    A carborane containing Gd-DTPA (diethylenetriaminepentaacetate) complex 2 was synthesized using a palladium-catalyzed C-C bond forming reaction. The evaluation of the Gd-carborane complex 2 as a MR imaging and boron carrier agent was carried out in vivo by means of MRI, ICP-AES, and α-autoradiography. The MR imaging revealed that the carborane Gd-DTPA 2 was metabolized slower in the body in comparison with Gd-DTPA 1. The results of ICP-AES method indicated that compound 2 was incorporated into normal tissues and metabolized quickly, whereas it was not accumulated into tumor and brain tissue. The α-autoradiography showed that a high level of boron was obtained in the internal organs and in the necrosis of tumor tissue. (author)

  4. Elemental composition of ambient aerosols measured with high temporal resolution using an online XRF spectrometer

    Directory of Open Access Journals (Sweden)

    M. Furger

    2017-06-01

    Full Text Available The Xact 625 Ambient Metals Monitor was tested during a 3-week field campaign at the rural, traffic-influenced site Härkingen in Switzerland during the summer of 2015. The field campaign encompassed the Swiss National Day fireworks event, providing increased concentrations and unique chemical signatures compared to non-fireworks (or background periods. The objective was to evaluate the data quality by intercomparison with other independent measurements and test its applicability for aerosol source quantification. The Xact was configured to measure 24 elements in PM10 with 1 h time resolution. Data quality was evaluated for 10 24 h averages of Xact data by intercomparison with 24 h PM10 filter data analysed with ICP-OES for major elements, ICP-MS for trace elements, and gold amalgamation atomic absorption spectrometry for Hg. Ten elements (S, K, Ca, Ti, Mn, Fe, Cu, Zn, Ba, Pb showed excellent correlation between the compared methods, with r2 values  ≥  0.95. However, the slopes of the regressions between Xact 625 and ICP data varied from 0.97 to 1.8 (average 1.28 and thus indicated generally higher Xact elemental concentrations than ICP for these elements. Possible reasons for these differences are discussed, but further investigations are needed. For the remaining elements no conclusions could be drawn about their quantification for various reasons, mainly detection limit issues. An indirect intercomparison of hourly values was performed for the fireworks peak, which brought good agreement of total masses when the Xact data were corrected with the regressions from the 24 h value intercomparison. The results demonstrate that multi-metal characterization at high-time-resolution capability of Xact is a valuable and practical tool for ambient monitoring.

  5. ICP analysis of zinc and zamak alloys

    International Nuclear Information System (INIS)

    Gomez Coedo, A.; Dorado Lopez, M.T.

    1987-01-01

    A study was carried out on the possibilities of inductively coupled plasma emission spectrometry (ICP) in the determination of Cu, Cd, Fe, Pb, Sn, Al and Mg in zinc-base materials using direct sample solutions. A selection of analytical lines is made, on account of both their sensitivity and the corresponding study of spectral interferences; measurable minimum contents and calibrated terms are also established, to conduce therefore to a complete methodology which allows determination of the mentioned elements within the contents established on the specifications of these materials. (author)

  6. Microfabricated hollow microneedle array using ICP etcher

    Science.gov (United States)

    Ji, Jing; Tay, Francis E. H.; Miao, Jianmin

    2006-04-01

    This paper presents a developed process for fabrication of hollow silicon microneedle arrays. The inner hollow hole and the fluidic reservoir are fabricated in deep reactive ion etching. The profile of outside needles is achieved by the developed fabrication process, which combined isotropic etching and anisotropic etching with inductively coupled plasma (ICP) etcher. Using the combination of SF6/O2 isotropic etching chemistry and Bosch process, the high aspect ratio 3D and high density microneedle arrays are fabricated. The generated needle external geometry can be controlled by etching variables in the isotropic and anisotropic cases.

  7. Microfabricated hollow microneedle array using ICP etcher

    International Nuclear Information System (INIS)

    Ji Jing; Tay, Francis E H; Miao Jianmin

    2006-01-01

    This paper presents a developed process for fabrication of hollow silicon microneedle arrays. The inner hollow hole and the fluidic reservoir are fabricated in deep reactive ion etching. The profile of outside needles is achieved by the developed fabrication process, which combined isotropic etching and anisotropic etching with inductively coupled plasma (ICP) etcher. Using the combination of SF 6 /O 2 isotropic etching chemistry and Bosch process, the high aspect ratio 3D and high density microneedle arrays are fabricated. The generated needle external geometry can be controlled by etching variables in the isotropic and anisotropic cases

  8. Microfabricated hollow microneedle array using ICP etcher

    Energy Technology Data Exchange (ETDEWEB)

    Ji Jing [Mechanical Engineering National University of Singapore, 119260, Singapore (Singapore); Tay, Francis E H [Mechanical Engineering National University of Singapore, 119260, Singapore (Singapore); Miao Jianmin [MicroMachines Center, School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 (Singapore)

    2006-04-01

    This paper presents a developed process for fabrication of hollow silicon microneedle arrays. The inner hollow hole and the fluidic reservoir are fabricated in deep reactive ion etching. The profile of outside needles is achieved by the developed fabrication process, which combined isotropic etching and anisotropic etching with inductively coupled plasma (ICP) etcher. Using the combination of SF{sub 6}/O{sub 2} isotropic etching chemistry and Bosch process, the high aspect ratio 3D and high density microneedle arrays are fabricated. The generated needle external geometry can be controlled by etching variables in the isotropic and anisotropic cases.

  9. Improving the throughput of the AES algorithm with multicore processors

    OpenAIRE

    Barnes, A.; Fernando, R.; Mettananda, K.; Ragel, R. G.

    2014-01-01

    AES, Advanced Encryption Standard, can be considered the most widely used modern symmetric key encryption standard. To encrypt/decrypt a file using the AES algorithm, the file must undergo a set of complex computational steps. Therefore a software implementation of AES algorithm would be slow and consume large amount of time to complete. The immense increase of both stored and transferred data in the recent years had made this problem even more daunting when the need to encrypt/decrypt such d...

  10. Dating of Uranium Materials by Using Combination of ICP-MS and SIMS

    International Nuclear Information System (INIS)

    Stebelkov, Y.; Aleshin, M.; Elantyev, I.; Grachev, A.; Zhizhin, K.; Stebelkov, V.

    2015-01-01

    The age of nuclear and some other radioactive materials can be determined undoubtedly by using ICP-MS techniques. But it can be correct if only one nuclear or another radioactive material is presented in analyzed sample and no isotope-chronograph presented in background particles in significant quantities. For particle analysis, which can be implemented by using SIMS, these restrictions are not valid. Practically one particle always characterizes only one material and does not contain background isotopes-chronographs. But age determination is based on the result of measuring of the content ratio of Th230 and U234. The difference of ionization coefficients of uranium and thorium and dependence of these coefficients on composition of particle does not allow using this method directly for age determination. Nevertheless SIMS is useful for dating of uranium materials, especially if the sample can contain small amounts of different materials. In this case the analysis of different fragments of materials by SIMS can confirm or not confirm the result, had been obtained by ICP-MS. If all detected and analyzed particles and fragments will have the same ratio of ion currents of Th230 and U234, the result of ICP-MS is true. If particles and fragments will have different ratios the result of ICP-MS cannot be related to any of presented materials. But in the last case the ages of different materials can be still estimated if different fragments have different ages, but the same elemental composition. The ''age'' had been determined by ICP-MS can be correlated with the average ratio of ion currents of Th230 and U234 had been determined by SIMS for all analyzed particles or fragments. This correlation determines the ratio of ionization coefficients of uranium and thorium, which should be the same for particles with the same elemental composition. (author)

  11. Analytical applications of atomic spectroscopy, with particular reference to inductively coupled plasma emission analysis of coal and fly ash

    International Nuclear Information System (INIS)

    Pougnet, M.A.B.

    1983-08-01

    This thesis outlines the analytical applications of atomic emission and absorption spectroscopy to a variety of materials. Special attention was directed to the analysis of coal and coal ashes. A simple slurry sampling technique was developed and used to determine V, Ni, Co, Mo and Mn in the National Bureau of Standards Standard Reference Materials (NBS-SRM) coals 1632a and 1635 by furnace atomic absorption spectroscopy (FAAS). Coal and fly ash were analysed by inductively coupled plasma atomic emission spectroscopy (ICP-AES). The determination of B, Be, Li, C, K and other trace elements by ICP-AES was investigated. Analytical methods were developed for the analysis of coal, fly ash and water samples. Fusion with sodium carbonate and a digestion bomb dissolution method were compared for the determination of boron in a South African boron-rich mineral (Kornerupine). Eight elements were determined in 10 industrial water samples from a power plant. Ca, Mg, Si and B were determined by ICP-AES and V, Ni, Co and Mo by FAAS. Various problems encountered during the course of the work and interferences in ICP-AES analysis are discussed. Some recommendations concerning method development and routine analysis by this technique are suggested

  12. High-precision timing of Nanhai coral by using MC-ICP-MS and TIMS techniques and its paleo-environmental significance

    International Nuclear Information System (INIS)

    Peng Zicheng; Nie Baofu; Chen Tegu

    2004-01-01

    The techniques of thermal ionization mass spectrometry (TIMS) and multicollector-inductively coupled plasma-mass spectrometry (MC-ICP-MS) were used for the high-precision timing of the domestic stalagmite standard (GBW04412), international coral standard (RKM-4) and the Nanhai corals. The results of uranium contents and the ratios of 234 U/ 238 U and 230 Th/ 234 U in the two standards measured by using two techniques were consistent within the error range. Most of the Nanhai corals have less than 3 μg/g of the uranium contents and 150 ± 5 of the δ 234 U(T) values, which means that the corals have not been subjected to the alternation since they were brought up 7000 years ago, therefore, they preserve the original environmental signals. The age sequence of the corals shows that three events of the high sea level happened in Nanhai area in the periods corresponding to 6799-6307 a B.P., 4472-4285 a B.P. and 1279-1012 a B.P. respectively. The above-mentioned three stages were relative to the Megathermal and Medieval Warm Periods in our country. (authors)

  13. Measurement of highly active samples of ultrashort-lived radionuclides and its problems

    International Nuclear Information System (INIS)

    van der Baan, J.G.; Panek, K.J.

    1985-01-01

    The measurement of highly active eluates obtained from the generators for ultrashort-lived radionuclides poses several problems which are briefly discussed by using the example of the /sup 195m/Hg→/sup 195m/Au generator. For overcoming some of the problems, the construction of a multiple single-channel analyzer that allows high count rates, is described, as well as the counting technique applicable for highly active eluates

  14. Validation and empirical correction of MODIS AOT and AE over ocean

    Directory of Open Access Journals (Sweden)

    N. A. J. Schutgens

    2013-09-01

    Full Text Available We present a validation study of Collection 5 MODIS level 2 Aqua and Terra AOT (aerosol optical thickness and AE (Ångström exponent over ocean by comparison to coastal and island AERONET (AErosol RObotic NETwork sites for the years 2003–2009. We show that MODIS (MODerate-resolution Imaging Spectroradiometer AOT exhibits significant biases due to wind speed and cloudiness of the observed scene, while MODIS AE, although overall unbiased, exhibits less spatial contrast on global scales than the AERONET observations. The same behaviour can be seen when MODIS AOT is compared against Maritime Aerosol Network (MAN data, suggesting that the spatial coverage of our datasets does not preclude global conclusions. Thus, we develop empirical correction formulae for MODIS AOT and AE that significantly improve agreement of MODIS and AERONET observations. We show these correction formulae to be robust. Finally, we study random errors in the corrected MODIS AOT and AE and show that they mainly depend on AOT itself, although small contributions are present due to wind speed and cloud fraction in AOT random errors and due to AE and cloud fraction in AE random errors. Our analysis yields significantly higher random AOT errors than the official MODIS error estimate (0.03 + 0.05 τ, while random AE errors are smaller than might be expected. This new dataset of bias-corrected MODIS AOT and AE over ocean is intended for aerosol model validation and assimilation studies, but also has consequences as a stand-alone observational product. For instance, the corrected dataset suggests that much less fine mode aerosol is transported across the Pacific and Atlantic oceans.

  15. Identification of sequences in herpes simplex virus type 1 ICP22 that influence RNA polymerase II modification and viral late gene expression.

    Science.gov (United States)

    Bastian, Thomas W; Rice, Stephen A

    2009-01-01

    Previous studies have shown that the herpes simplex virus type 1 (HSV-1) immediate-early protein ICP22 alters the phosphorylation of the host cell RNA polymerase II (Pol II) during viral infection. In this study, we have engineered several ICP22 plasmid and virus mutants in order to map the ICP22 sequences that are involved in this function. We identify a region in the C-terminal half of ICP22 (residues 240 to 340) that is critical for Pol II modification and further show that the N-terminal half of the protein (residues 1 to 239) is not required. However, immunofluorescence analysis indicates that the N-terminal half of ICP22 is needed for its localization to nuclear body structures. These results demonstrate that ICP22's effects on Pol II do not require that it accumulate in nuclear bodies. As ICP22 is known to enhance viral late gene expression during infection of certain cultured cells, including human embryonic lung (HEL) cells, we used our engineered viral mutants to map this function of ICP22. It was found that mutations in both the N- and C-terminal halves of ICP22 result in similar defects in viral late gene expression and growth in HEL cells, despite having distinctly different effects on Pol II. Thus, our results genetically uncouple ICP22's effects on Pol II from its effects on viral late gene expression. This suggests that these two functions of ICP22 may be due to distinct activities of the protein.

  16. ICP-MS/MS-Based Ionomics: A Validated Methodology to Investigate the Biological Variability of the Human Ionome.

    Science.gov (United States)

    Konz, Tobias; Migliavacca, Eugenia; Dayon, Loïc; Bowman, Gene; Oikonomidi, Aikaterini; Popp, Julius; Rezzi, Serge

    2017-05-05

    We here describe the development, validation and application of a quantitative methodology for the simultaneous determination of 29 elements in human serum using state-of-the-art inductively coupled plasma triple quadrupole mass spectrometry (ICP-MS/MS). This new methodology offers high-throughput elemental profiling using simple dilution of minimal quantity of serum samples. We report the outcomes of the validation procedure including limits of detection/quantification, linearity of calibration curves, precision, recovery and measurement uncertainty. ICP-MS/MS-based ionomics was used to analyze human serum of 120 older adults. Following a metabolomic data mining approach, the generated ionome profiles were subjected to principal component analysis revealing gender and age-specific differences. The ionome of female individuals was marked by higher levels of calcium, phosphorus, copper and copper to zinc ratio, while iron concentration was lower with respect to male subjects. Age was associated with lower concentrations of zinc. These findings were complemented with additional readouts to interpret micronutrient status including ceruloplasmin, ferritin and inorganic phosphate. Our data supports a gender-specific compartmentalization of the ionome that may reflect different bone remodelling in female individuals. Our ICP-MS/MS methodology enriches the panel of validated "Omics" approaches to study molecular relationships between the exposome and the ionome in relation with nutrition and health.

  17. ICP-MS Technology and Its Application to Study of Environmental Radioactivity

    International Nuclear Information System (INIS)

    Syarbaini

    2000-01-01

    Study on the behaviour of artificial radionuclides in environment can be performed by investigation of fallout radionuclides that were distributed in ecosystem components. Fall out radionuclides are artificial radionuclides distributed by the nuclear weapon test explosions at atmosphere in several ten years ago. The concentration of these radionuclides in ecosystem components are very low. For the measurement of their concentrations in environmental samples by conventional radiometric methods need a large samples, complicated chemical separation and long counting time. Application of ICP-MS is good alternative to solve this problem. ICP-MS (Inductively Coupled Plasma Mass Spectrometry) is multi elements analysis instrument that wide used in the field of analytical chemistry. It can determine elements at a concentration level of pg/ml in several minutes per sample without a long chemical separation and preconcentration process. (author)

  18. Following the evolution of morphology, composition and crystallography of alumina based catalysts after laser ablation: Implications for analysis by LA-ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Alloncle, G. [Universite de Lyon, Lyon1, Laboratoire des Sciences Analytiques, CNRS UMR 5180, bat CPE, 43, boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex (France); Direction Physique et Analyses, Institut Francais du Petrole (IFP)-Lyon, BP3, F-69360 Solaize (France); Gilon, N., E-mail: gilon@univ-lyon1.fr [Universite de Lyon, Lyon1, Laboratoire des Sciences Analytiques, CNRS UMR 5180, bat CPE, 43, boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex (France); Legens, C.; Lienemann, C.-P.; Rebours, B.; Sorbier, L. [Direction Physique et Analyses, Institut Francais du Petrole (IFP)-Lyon, BP3, F-69360 Solaize (France); Morin, S.; Revel, R. [Direction Catalyse et Separation, Institut Francais du Petrole (IFP)-Lyon, BP3, F-69360 Solaize (France)

    2009-08-30

    Fundamental understanding of aerosol formation during laser ablation is important for the development of LA-ICP analysis of complex samples. Using a Lina Spark Atomizer{sup TM}, the application of this technique to the field of heterogeneous catalysis gave an accuracy of 5-15% while extreme values of +100% could be obtained in some cases. To improve understanding of laser ablation processes, particles generated during ablation of alumina based catalysts were collected and analysed using different microscopy and surface analysis techniques. Morphological study by scanning electron microscopy showed that most of the particles leaving the ablation cell were nanoparticle aggregates generated from vapor condensation. An XRD study of these aerosols revealed that the condensation converge on the formation of a spinel structure with large coherence domains. Elemental composition of the aerosol was also followed and exhibited differences between a catalyst containing large Mo concentration or low Pt concentration.

  19. A matrix effect and accuracy evaluation for the determination of elements in milk powder LIBS and laser ablation/ICP-OES spectrometry.

    Science.gov (United States)

    Gilon, N; El-Haddad, J; Stankova, A; Lei, W; Ma, Q; Motto-Ros, V; Yu, J

    2011-11-01

    Laser ablation coupled to inductively coupled plasma optical emission spectrometry (LA-ICP-OES) and laser-induced breakdown spectroscopy (LIBS) were investigated for the determination of Ca, Mg, Zn and Na in milk samples. The accuracy of both methods was evaluated by comparison of the concentration found using LA-ICP-OES and LIBS with classical wet digestion associated with ICP-OES determination. The results were not fully acceptable, with biases from less than 1% to more than 60%. Matrix effects were also investigated. The sample matrix can influence the temperature, electron number density (n (e)) and other excitation characteristics in the ICP. These ICP characteristics were studied and evaluated during ablation of eight milk samples. Differences in n (e) (from 8.9 to 13.8 × 10(14) cm(-3)) and rotational temperature (ranging from 3,400 to 4,400 K) occurred with no correlation with trueness. LIBS results obtained after classical external calibration procedure gave degraded accuracy, indicating a strong matrix effect. The LIBS measurements clearly showed that the major problem in LA-ICP was related to the ablation process and that LIBS spectroscopy is an excellent diagnostic tool for LA-ICP techniques.

  20. Determination of organic and inorganic mercury species in Sungai Kinta, Perak by reversed-phase high performance liquid chromatography (HPLC) on-line coupled with ICP-MS

    International Nuclear Information System (INIS)

    Norshidah Baharuddin; Norashikin Saim; Rozita Osman; Sharifuddin Mohd Zain

    2012-01-01

    This paper describes a simple method for mercury speciation in river water samples of Sungai Kinta, Perak. Separation and measurement were done by high-performance liquid chromatography on-line with inductively coupled plasma mass spectrometry (HPLC/ ICP-MS). Separation of mercury species was accomplished within 6 minutes on an AQ C18 4.6 mm i.d x 150 mm, 5 μm reversed phase column with 0.1 % (w/ v) L-cysteine as mobile phase. Under the optimum instrumental conditions, recoveries of 101-104 % for MeHg + and 96 - 104 % for Hg 2+ were obtained with experimental detection limits of 1ngL -1 for inorganic mercury and 1.5 μgL -1 for organic mercury. (author)