WorldWideScience

Sample records for high voltage tests

  1. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  2. High Voltage Pulse Testing Survey.

    Science.gov (United States)

    1985-10-01

    Cryogenic 23 E. Liquids 26 F. Solids 28 1. Polyethylene 28 2. Cross-Linked Polyethylene ( XLPE ) 29 3. Polyimide and Polyvenylchloride (PVC) 31 VI Benefits 35 A...Strength of XLPE Cables 29 vii * 4" I PROGRAM OBJECTIVES The Pulse Test Survey summarizes government, industry, and technical reports on high voltage pulse...system of silicone oil on a XLPE (cross-linked polyethylene) spacer tends to lower the impulse breakdown by approximately 10 percent. The negative impulse

  3. High-voltage engineering and testing

    CERN Document Server

    Ryan, Hugh M

    2013-01-01

    This 3rd edition of High Voltage Engineering Testing describes strategic developments in the field and reflects on how they can best be managed. All the key components of high voltage and distribution systems are covered including electric power networks, UHV and HV. Distribution systems including HVDC and power electronic systems are also considered.

  4. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  5. High voltage testing for the MAJORANA DEMONSTRATOR

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Arnquist, I.J. [Pacific Northwest National Laboratory, Richland, WA (United States); Avignone, F.T. [Department of Physics and Astronomy, University of South Carolina, Columbia, SC (United States); Oak Ridge National Laboratory, Oak Ridge, TN (United States); Barabash, A.S. [National Research Center “Kurchatov Institute” Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Bertrand, F.E. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Bradley, A.W. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Brudanin, V. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Busch, M. [Department of Physics, Duke University, Durham, NC (United States); Triangle Universities Nuclear Laboratory, Durham, NC (United States); Buuck, M. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); Byram, D. [Department of Physics, University of South Dakota, Vermillion, SD (United States); Caldwell, A.S. [South Dakota School of Mines and Technology, Rapid City, SD (United States); Chan, Y-D. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Christofferson, C.D. [South Dakota School of Mines and Technology, Rapid City, SD (United States); Chu, P.-H. [Los Alamos National Laboratory, Los Alamos, NM (United States); Cuesta, C., E-mail: ccuesta@uw.edu [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); Detwiler, J.A.; Doe, P.J. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); and others

    2016-07-01

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in {sup 76}Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA DEMONSTRATOR. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA DEMONSTRATOR was characterized and the micro-discharge effects during the MAJORANA DEMONSTRATOR commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  6. High voltage testing for the MAJORANA DEMONSTRATOR

    Science.gov (United States)

    Abgrall, N.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Bertrand, F. E.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Doe, P. J.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Fu, Z.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; Li, A.; MacMullin, J.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Orrell, J. L.; O'Shaughnessy, C.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, A. M.; Tedeschi, D.; Thompson, A.; Ton, K. T.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.

    2016-07-01

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA DEMONSTRATOR. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA DEMONSTRATOR was characterized and the micro-discharge effects during the MAJORANA DEMONSTRATOR commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  7. High voltage testing for the Majorana Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N.; Arnquist, Isaac J.; Avignone, F. T.; Barabash, A.; Bertrand, F.; Bradley, A. W.; Brudanin, V.; Busch, Matthew; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Yuen-Dat; Christofferson, C. D.; Chu, Pamela M.; Cuesta, C.; Detwiler, Jason A.; Doe, P. J.; Dunagan, C.; Efremenko, Yuri; Ejiri, H.; Elliott, S. R.; Fu, Z.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I.; Guiseppe, V. E.; Henning, R.; Hoppe, Eric W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K.; Kidd, M. F.; Konovalov, S.; Kouzes, Richard T.; Laferriere, Brian D.; Leon, Jonathan D.; Li, Alexander D.; MacMullin, J.; Martin, R. D.; Massarcyk, R.; Meijer, S. J.; Mertens, S.; Orrell, John L.; O' Shaughnessy, C.; Poon, Alan W.; Radford, D. C.; Rager, J.; Rielage, Keith; Robertson, R. G. H.; Romero Romo, M.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, Anne-Marie E.; Tedeschi, D.; Thompson, Andrew; Ton, K. T.; Trimble, J. E.; Varner, R. L.; Vasilyev, Sergey; Vetter, Kai; Vorren, Kris R.; White, Brandon R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, Chang-Hong; Yumatov, V.

    2016-07-01

    The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  8. High-voltage test and measuring techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hauschild, Wolfgang; Lemke, Eberhard

    2014-04-01

    Reflects the unit of both HV testing and measuring technique. Intended as an ''application guide'' for the relevant IEC standards. Refers also to future trends in HV testing and measuring technique. With numerous illustrations. It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  9. High voltage testing for the MAJORANA Demonstrator

    CERN Document Server

    Abgrall, N; Avignone, F T; Barabash, A S; Bertrand, F E; Bradley, A W; Brudanin, V; Busch, M; Buuck, M; Byram, D; Caldwell, A S; Chan, Y-D; Christofferson, C D; Chu, P -H; Cuesta, C; Detwiler, J A; Doe, P J; Dunagan, C; Efremenko, Yu; Ejiri, H; Elliott, S R; Fu, Z; Galindo-Uribarri, A; Giovanetti, G K; Goett, J; Green, M P; Gruszko, J; Guinn, I S; Guiseppe, V E; Henning, R; Hoppe, E W; Howard, S; Howe, M A; Jasinski, B R; Keeter, K J; Kidd, M F; Konovalov, S I; Kouzes, R T; LaFerriere, B D; Leon, J; Li, A; MacMullin, J; Martin, R D; Massarczyk, R; Meijer, S J; Mertens, S; Orrell, J L; O'Shaughnessy, C; Poon, A W P; Radford, D C; Rager, J; Rielage, K; Robertson, R G H; Romero-Romero, E; Shanks, B; Shirchenko, M; Snyder, N; Suriano, A M; Tedeschi, D; Thompson, A; Ton, K T; Trimble, J E; Varner, R L; Vasilyev, S; Vetter, K; Vorren, K; White, B R; Wilkerson, J F; Wiseman, C; Xu, W; Yakushev, E; Yu, C -H; Yumatov, V

    2016-01-01

    The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This eff?ect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including diff?erent improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge eff?ects during the MAJORANA Demonstrator commissioning phase were studied. A stable c...

  10. High Voltage Tests in the LUX-ZEPLIN System Test

    Science.gov (United States)

    Whitis, Thomas; Lux-Zeplin Collaboration

    2016-03-01

    The LUX-ZEPLIN (LZ) project is a dark matter direct detection experiment using liquid xenon. The detector is a time projection chamber (TPC) requiring the establishment of a large electric field inside of the detector in order to drift ionization electrons. Historically, many xenon TPC designs have been unable to reach their design fields due to light production and breakdown. The LZ System Test is scaled so that with a cathode voltage of -50 kV, it will have the fields that will be seen in the LZ detector at -100 kV. It will use a fully instrumented but scaled-down version of the LZ TPC design with a vessel set and gas system designed for quick turnaround, allowing for iterative modifications to the TPC prototype and instrumentation. This talk will present results from the high voltage tests performed during the first runs of the LZ System Test.

  11. Challenges for High Voltage Testing of UHV Equipment

    Institute of Scientific and Technical Information of China (English)

    Ernst Gockenbach

    2011-01-01

    The increase of voltage level for AC and DC transmission systems requires some changes in the high voltage testing for Ultra High Voltage (UHV) equipment. After a short description of the coordination work in the standard- ization bodies the requirements for UHV equipment are mentioned. The main points concerning high voltage testing of UHV equipment are the impulse shape of standard lightning impulse voltage, the evaluation of the test voltage for impulses with oscillations or overshoot near the peak and the time parameter of switching impulses. The linearity check of the measuring devices, the proximity effect, the wet tests and the atmospheric correction factors are further points to be discussed concerning testing of UHV equipment.

  12. [Design of a high-voltage insulation testing system of X-ray high frequency generators].

    Science.gov (United States)

    Huang, Yong; Mo, Guo-Ming; Wang, Yan; Wang, Hong-Zhi; Yu, Jie-Ying; Dai, Shu-Guang

    2007-09-01

    In this paper, we analyze the transformer of X-ray high-voltage high-frequency generators and, have designed and implemented a high-voltage insulation testing system for its oil tank using full-bridge series resonant soft switching PFM DC-DC converter.

  13. A high-voltage test for the ATLAS RPC qualification

    CERN Document Server

    Aielli, G; Cardarelli, R; Di Ciaccio, A; Di Simone, A; Liberti, B; Santonico, R

    2004-01-01

    The RPC production sequence for the ATLAS experiment includes a specific test of current absorption at the operating point, which concerns the RPC "gas volumes", namely the bare detectors not yet assembled with the read-out panels and the mechanical support structures. The test, which is carried out at the production site, consists of two phases. The gas volumes are initially conditioned with pure argon, keeping the voltage constant just above the breakdown value of about 2 kV. The final test, performed after the volumes have undergone inner surface varnishing with linseed oil, is based on the measurement of the current-voltage characteristics with the binary operating gas, C//2H//2F//4/i-C//4H//1//0 = 95/5. The results presented here concern 45% of the total foreseen production.

  14. High-Voltage Terminal Test of Test Stand for 1-MV Electrostatic Accelerator

    CERN Document Server

    Park, Sae-Hoon

    2015-01-01

    The Korea Multipurpose Accelerator Complex (KOMAC) has been developing a 300-kV test stand for a 1-MV electrostatic accelerator ion source. The ion source and accelerating tube will be installed in a high-pressure vessel. The ion source in the high-pressure vessel is required to have a high reliability. The test stand has been proposed and developed to confirm the stable operating conditions of the ion source. The ion source will be tested at the test stand to verify the long-time operating conditions. The test stand comprises a 300-kV high-voltage terminal, a battery for the ion-source power, a 60-Hz inverter, 200-MHz RF power, a 5-kV extraction power supply, a 300-kV accelerating tube, and a vacuum system. The results of the 300-kV high-voltage terminal tests are presented in this paper.

  15. Installation and cosmic ray test of the high voltage system of the BESⅢdrift chamber

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    After examination of the designed high voltage power supply system of the BESⅢ drift chamber in the beam test of the full length prototype of drift chamber,a full system covering all the channels of high voltage was installed.The system's training and the high voltage value adjustment were carried out in the cosmic ray test of the BESⅢ drift chamber.The cosmic ray test for the full system and its final installation on the BESⅢ drift chamber were reported.The full system of high voltage power supply works stably and reliably.

  16. High Voltage Testing of a 5-meter Prototype Triaxial HTS Cable

    Energy Technology Data Exchange (ETDEWEB)

    Sauers, Isidor [ORNL; James, David Randy [ORNL; Ellis, Alvin R [ORNL; Tuncer, Enis [ORNL; Pace, Marshall O [ORNL; Gouge, Michael J [ORNL; Demko, Jonathan A [ORNL; Lindsay, David T [ORNL

    2007-01-01

    High voltage tests were performed on a 5-m long prototype triaxial HTS cable (supplied by Ultera) at ORNL in preparation for installation of a 200-m HTS cable of the same design at the AEP utility substation in Columbus, Ohio. The triaxial design comprises three concentric phases and shield around a common former with the phase to phase dielectric at cryogenic temperature. Advantages of this design include increased current density, a reduced amount of HTS tape needed, and reduced heat load. The phase to phase voltage will be 13.2 kVrms (7.6 kVrms to ground). Preliminary testing was done on half-scale and full-scale terminations which successfully passed AC withstand, partial discharge, and impulse tests. High voltage tests conducted on the 5-m cable with the cable straight and after bending 90 degrees were ac withstand to 39 kVrms, partial discharge inception, and a minimum of 10 positive and 10 negative lightning waveform impulses at 110 kV. Phase to phase insulation was tested by applying high voltage to each phase one at a time with all the other phases grounded. Partial discharge data will be presented. The 5-m prototype triaxial HTS cable passed all the HV tests performed, with a PD inception voltage significantly above the required voltage.

  17. Diagnostics and testing of high voltage cable systems

    Energy Technology Data Exchange (ETDEWEB)

    Hyvoenen, P.; Oyegoke, B.; Aro, M.

    2003-07-01

    Reliability demands on electricity generation and distribution are increasing. Power utilities have faced new challenges due to liberalisation of electricity markets, increasing authors regulation and new claims for compensation of unexpected power shut downs. As a result power utilities have to concentrate more on asset management to reduce costs, to postpone investments, to optimise technical management keeping at the same time reliability and power quality at high level. Nowadays it is important to do right things at right place at right time. Maintenance strategy is changing from predictive or repairing maintenance to the condition based maintenance (CBM). Success of CBM depends partly on how good and reliable tools are available to determine condition of electrical apparatus. Cables have been used in electricity distribution since beginning of 20th century. Oldest still in use cables in Finland has been installed late 1940's. Nowadays almost all new distribution systems in urban areas are done using cables. Wide variety of cables are in use. Knowledge of condition and history of cables is not so well documented. Professional skill to install cable systems is disappearing due to outsourcing of maintenance groups. There is a worry about increasing amount of after installation faults due to loosing of professional skills to install cable systems. Wide variety of cable insulation systems and large variety in ages of cables still in use will place hard challenges for cable condition assessment. Earlier studies showed that measurement of insulation resistance is almost only diagnostic measurement performed to cable systems. Knowledge and experience of new diagnostic method is not so widely distributed. Based on previous project, dielectric response (DR) measurement and partial discharge (PD) measurement seemed to be most promising tools for the condition assessment of cable systems. Increased moisture content in oil-paper insulated cable or water trees in

  18. High voltage engineering fundamentals

    CERN Document Server

    Kuffel, E; Hammond, P

    1984-01-01

    Provides a comprehensive treatment of high voltage engineering fundamentals at the introductory and intermediate levels. It covers: techniques used for generation and measurement of high direct, alternating and surge voltages for general application in industrial testing and selected special examples found in basic research; analytical and numerical calculation of electrostatic fields in simple practical insulation system; basic ionisation and decay processes in gases and breakdown mechanisms of gaseous, liquid and solid dielectrics; partial discharges and modern discharge detectors; and over

  19. High Voltage Plateau and Data Reliability Test for the DSNC Troubleshooting

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwang-June; Jeong, Jeong-Whan; Kang, Hee-Young; Shin, Hee-Sung; Kim, Ho-Dong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2006-07-01

    DSNC(Dupic safeguard neutron counter) was installed in the Dupic fuel development facility (DFDF) for the nuclear material accounting in the end of 1990s and had operated normally until 2003. But there have been a problem after that time. It has an abnormal state in the function of counting the neutrons emitting from the Dupic process product as well as the spent nuclear fuel at present. In this study, high voltage plateau and data acquisition reliability test were carried out as a method of troubleshooting for DSNC. As a result of the test, it was confirmed that the high voltage plateau was not formed but data acquisition reliability was good at some high voltages and at 6V applied to the electronic circuit of the counter.

  20. On-site Testing and PD Diagnosis of High Voltage Power Cables

    NARCIS (Netherlands)

    Gulski, E.; Cichecki, P.; Wester, F.; Smit, J.J.; Bodega, R.; Hermans, T.J.W.H.; Seitz, P.P.; Quak, B.; De Vries, F.

    2008-01-01

    In addition to after-laying of new-installed high voltage (HV) power cables the use of on-site non-destructive on-site testing and diagnosis of service aged power cables is becoming an important issue to determine the actual condition of the cable systems and to determine the future performances. In

  1. High voltage pulse generator

    Science.gov (United States)

    Fasching, George E.

    1977-03-08

    An improved high-voltage pulse generator has been provided which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of a first one of the rectifiers connected between the first and second of the plurality of charging capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. Alternate circuits are provided for controlling the application of the charging voltage from a charging circuit to be applied to the parallel capacitors which provides a selection of at least two different intervals in which the charging voltage is turned "off" to allow the SCR's connecting the capacitors in series to turn "off" before recharging begins. The high-voltage pulse-generating circuit including the N capacitors and corresponding SCR's which connect the capacitors in series when triggered "on" further includes diodes and series-connected inductors between the parallel-connected charging capacitors which allow sufficiently fast charging of the capacitors for a high pulse repetition rate and yet allow considerable control of the decay time of the high-voltage pulses from the pulse-generating circuit.

  2. Qualification High Voltage Testing of Short Triax HTS Cables in the Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    James, David Randy [ORNL; Sauers, Isidor [ORNL; Ellis, Alvin R [ORNL; Tuncer, Enis [ORNL; Gouge, Michael J [ORNL; Demko, Jonathan A [ORNL; Duckworth, Robert C [ORNL; Rey, Christopher M [ORNL

    2009-01-01

    In order to qualify the electrical insulation design of future HTS cables installed in the electric grid, a number of high voltage qualification tests are generally performed in the laboratory on either single-phase model cables and/or actual three-phase cable samples. Prior to installation of the 200-m Triax HTS cable at the American Electric Power Bixby substation near Columbus, Ohio, in September, 2006, such tests were conducted on both single-phase model cables made at ORNL and tri-axial cable sections cut off from cable made on a production run. The three-phase tri-axial design provides some specific testing challenges since the ground shield and three phases are concentric about a central former with each phase separated by dielectric tape insulation immersed in liquid nitrogen. The samples were successfully tested and qualified for partial discharge inception, AC withstand, and lightning impulse where voltage is applied to one phase with the other phases grounded. In addition one of the phase pairs was tested for dc withstand as a ldquoworst caserdquo scenario to simulate the effect of VLF (Very Low Frequency) tests on the actual cable installed at the Bixby site. The model and prototype cables will be described and the high voltage test results summarized.

  3. High-voltage testing of a 500-kV dc photocathode electron gun

    Science.gov (United States)

    Nagai, Ryoji; Hajima, Ryoichi; Nishimori, Nobuyuki; Muto, Toshiya; Yamamoto, Masahiro; Honda, Yosuke; Miyajima, Tsukasa; Iijima, Hokuto; Kuriki, Masao; Kuwahara, Makoto; Okumi, Shoji; Nakanishi, Tsutomu

    2010-03-01

    A high-voltage dc photocathode electron gun was successfully conditioned up to a voltage of 550 kV and a long-time holding test for 8 h was demonstrated at an acceleration voltage of 500 kV. The dc photocathode electron gun is designed for future light sources based on energy-recovery linac and consists of a Cockcroft-Walton generator, a segmented cylindrical ceramic insulator, guard-ring electrodes, a support-rod electrode, a vacuum chamber, and a pressurized insulating gas tank. The segmented cylindrical ceramic insulator and the guard-ring electrodes were utilized to prevent any damage to the insulator from electrons emitted by the support-rod electrode.

  4. The progress of funnelling gun high voltage condition and beam test

    Energy Technology Data Exchange (ETDEWEB)

    Wang, E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Gassner, D. M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Lambiase, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Meng, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Rahman, O. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pikin, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Rao, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Sheehy, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Skaritka, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pietz, J. [Transfer Engineering and Manufacturing, Inc., Fremont, CA (United States); Ackeret, M. [Transfer Engineering and Manufacturing, Inc., Fremont, CA (United States); Yeckel, C. [Thompson, Stangenes Industries, Palo Alto, CA (United States); Miller, R. [Thompson, Stangenes Industries, Palo Alto, CA (United States); Dobrin, E. [Thompson, Stangenes Industries, Palo Alto, CA (United States); Thompson, K. [Thompson, Stangenes Industries, Palo Alto, CA (United States)

    2015-05-03

    A prototype of a high average current polarized electron funneling gun as an eRHIC injector has been built at BNL. The gun was assembled and tested at Stangenes Incorporated. Two beams were generated from two GaAs photocathodes and combined by a switched combiner field. We observed the combined beams on a YAG crystal and measured the photocurrent by a Faraday cup. The gun has been shipped to Stony Brook University and is being tested there. In this paper we will describe the major components of the gun and recent beam test results. High voltage conditioning is discussed as well.

  5. Testing to Investigate Stress-LifetimeCharacteristics of High Voltage Printed Circuit Boards

    Science.gov (United States)

    El Korashy, Oliver; Franke, Andreas; Gollor, Matthias

    2014-08-01

    Printed circuit boards (PCBs) are typically used in all electronic equipment, including those conditioning or controlling high voltage (HV) for space satellite applications. With the use of new subsystems that require higher voltages (generally several hundred volts up to tens of kV), stress-lifetime issues are becoming more complex. In order to allow compact design and cost efficient production of HV modules, there is an increasing demand to improve the design of PCBs with encapsulation or conformal coating at higher voltages.Within a PCB there are a number of electrical field interfaces each of which can have individual stress- lifetime characteristics, and the influence of environmental aging should also be considered, which means a large number of sample types should be tested to gain experimental evidence to define the margin for each interface. This paper demonstrates a method to test multiple samples at a fixed DC voltage stress until the event of a breakdown, and presents test results from 6 single-sided encapsulated PCB samples.

  6. Tests of industrial ethylene-propylene rubber high voltage cable for cryogenic use

    CERN Document Server

    Balhan, B; Goddard, B; Muratori, G; Otwinowski, S; Rieubland, Jean Michel; Wang, H; CERN. Geneva. SPS and LEP Division

    1999-01-01

    At the beginning of 1999 UCLA has received a prototype High Voltage Cryogenic Cable supplied fee of charge by Pirelli. The cable is intended for more than ten years of service at 100 kV D.C. and liquid argon temperature. Thecable uses an all welded construction, whichi is axially tight and free of ionizable voids. The cable was submitted to a number of mechanical and electrical tests as described below.

  7. Test Results from a Simulated High Voltage Lunar Power Transmission Line

    Science.gov (United States)

    Birchenough, Arthur; Hervol, David

    2008-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was modified to simulate high voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high frequency AC power to a lunar facility located at a distance.

  8. Test Results From a Simulated High-Voltage Lunar Power Transmission Line

    Science.gov (United States)

    Birchenough, Arthur; Hervol, David

    2008-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio was modified to simulate high-voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high-frequency ac power to a lunar facility located at a distance.

  9. Performance and Environmental Test Results of the High Voltage Hall Accelerator Engineering Development Unit

    Science.gov (United States)

    Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Shastry, Rohit; Pinero, Luis; Peterson, Todd; Mathers, Alex

    2012-01-01

    NASA Science Mission Directorate's In-Space Propulsion Technology Program is sponsoring the development of a 3.5 kW-class engineering development unit Hall thruster for implementation in NASA science and exploration missions. NASA Glenn and Aerojet are developing a high fidelity high voltage Hall accelerator that can achieve specific impulse magnitudes greater than 2,700 seconds and xenon throughput capability in excess of 300 kilograms. Performance, plume mappings, thermal characterization, and vibration tests of the high voltage Hall accelerator engineering development unit have been performed. Performance test results indicated that at 3.9 kW the thruster achieved a total thrust efficiency and specific impulse of 58%, and 2,700 sec, respectively. Thermal characterization tests indicated that the thruster component temperatures were within the prescribed material maximum operating temperature limits during full power thruster operation. Finally, thruster vibration tests indicated that the thruster survived the 3-axes qualification full-level random vibration test series. Pre and post-vibration test performance mappings indicated almost identical thruster performance. Finally, an update on the development progress of a power processing unit and a xenon feed system is provided.

  10. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  11. Technological Aspects: High Voltage

    CERN Document Server

    Faircloth, D C

    2013-01-01

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered.

  12. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  13. Design, construction, and test of a passive optical prototype high voltage instrument transformer

    DEFF Research Database (Denmark)

    Christensen, Lars Hofmann

    1995-01-01

    This paper describes an optical voltage transformer (OVT) for a 132-130 kV system based on the Pockels effect in a Bi4Ge3O12 crystal. Different from the majority of OVTs reported, this construction does not use any capacitive voltage division. To accomplish this, it was necessary to redesign...... the optical modulator. A prototype of the OVT has been constructed and tested...

  14. Compact Low-Voltage, High-Power, Multi-beam Klystron for ILC: Initial Test Results

    CERN Document Server

    Teryaev, V E; Kazakov, S Yu; Hirshfield, J L; Ives, R L; Marsden, D; Collins, G; Karimov, R; Jensen, R

    2015-01-01

    Initial test results of an L-band multi-beam klystron with parameters relevant for ILC are presented. The chief distinction of this tube from MBKs already developed for ILC is its low operating voltage of 60 kV, a virtue that implies considerable technological simplifications in the accelerator complex. To demonstrate the concept underlying the tubes design, a six-beamlet quadrant (a 54 inch high one-quarter portion of the full 1.3 GHz tube) was built and recently underwent initial tests, with main goals of demonstrating rated gun perveance, rated gain, and at least one-quarter of the full 10-MW rated power. Our initial three-day conditioning campaign without RF drive (140 microsec pulses @ 60 Hz) was stopped at 53% of full rated duty because of time-limits at the test-site; no signs appeared that would seem to prevent achieving full duty operation (i.e., 1.6 msec pulses @ 10 Hz). The subsequent tests with 10-15 microsec RF pulses confirmed the rated gain, produced output powers of up to 2.86 MW at 60 kV with...

  15. ELABORATION AND TESTING OF SOFTWARE FOR SIGNAL PROCESSING OF RESISTIVE HIGH VOLTAGE DIVIDER

    Directory of Open Access Journals (Sweden)

    Sit М.

    2009-12-01

    Full Text Available Mathematical tools and the software for input in the computer of signals of a resistive divider of a high voltage of the industrial frequency, providing a split-hair accuracy of measurement of parameters of the basic and harmonics which are divisible to the basic is developed.

  16. High-voltage picoamperemeter

    Energy Technology Data Exchange (ETDEWEB)

    Bugl, Andrea; Ball, Markus; Boehmer, Michael; Doerheim, Sverre; Hoenle, Andreas; Konorov, Igor [Technische Universitaet Muenchen, Garching (Germany); Ketzer, Bernhard [Technische Universitaet Muenchen, Garching (Germany); Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany)

    2014-07-01

    Current measurements in the nano- and picoampere region on high voltage are an important tool to understand charge transfer processes in micropattern gas detectors like the Gas Electron Multiplier (GEM). They are currently used to e.g. optimize the field configuration in a multi-GEM stack to be used in the ALICE TPC after the upgrade of the experiment during the 2nd long shutdown of the LHC. Devices which allow measurements down to 1pA at high voltage up to 6 kV have been developed at TU Muenchen. They are based on analog current measurements via the voltage drop over a switchable shunt. A microcontroller collects 128 digital ADC values and calculates their mean and standard deviation. This information is sent with a wireless transmitting unit to a computer and stored in a root file. A nearly unlimited number of devices can be operated simultaneously and read out by a single receiver. The results can also be displayed on a LCD directly at the device. Battery operation and the wireless readout are important to protect the user from any contact to high voltage. The principle of the device is explained, and systematic studies of their properties are shown.

  17. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  18. Portable High Voltage Impulse Generator

    Directory of Open Access Journals (Sweden)

    S. Gómez

    2011-07-01

    Full Text Available This paper presents a portable high voltage impulse generator which was designed and built with insulation up to 20 kV. This design was based on previous work in which simulation software for standard waves was developed. Commercial components and low-cost components were used in this work; however, these particular elements are not generally used for high voltage applications. The impulse generators used in industry and laboratories are usually expensive; they are built to withstand extra high voltage and they are big, making them impossible to transport. The proposed generator is portable, thereby allowing tests to be made on devices that cannot be moved from their location. The results obtained with the proposed impulse generator were satisfactory in terms of time and waveforms compared to other commercial impulse generators and the standard impulse wave simulator.

  19. Field testing, modelling and analysis of ferroresonance in a high-voltage power system

    Science.gov (United States)

    Jacobson, David Allan Nils

    2000-11-01

    Catastrophic equipment failures continue to occur today due to ferroresonance even though this phenomenon has been extensively studied over the past ninety years. This thesis is concerned with the tasks of defining where ferroresonance problems can exist in a high voltage power system, of determining methods for displaying safety margins between nonferroresonant and ferroresonant operating regions and improving upon existing ferroresonance simulation techniques. Several different ferroresonant circuits have been modelled and compared with field measurements taken on the Manitoba Hydro 230-kV power system or compared with laboratory measurements including: a de-energized transformer connected to the grading capacitance of an open circuit breaker, a transformer-terminated doublecircuit transmission line and a coupling capacitor voltage transformer. In a high voltage power system, the most prevalent ferroresonance circuit occurs between a de-energized transformer and the grading capacitor of an open circuit breaker. Experimental work has shown that losses in a practical transformer are much larger during ferroresonance oscillation modes than predicted by conventional modelling techniques. A simple switched eddy-current loss resistor is found able to model the losses during subharmonic and fundamental frequency ferroresonance in a laboratory transformer. A major contribution of this work is a new method of visualizing the margin between nonferroresonant and ferroresonant states in a transformer/grading capacitor circuit has been developed. A general set of averaged equations is derived that permit the analysis of an nth order polynomial approximation of the magnetization curve. The location of the saddle points and slope of the stable manifold through the saddle points can be determined for a particular transformer under study. The Limacon of Pascal is found to be a good approximation to the geometric shape of the basin of attraction of the period-1 ferroresonant

  20. Design of load-to-failure tests of high-voltage insulation breaks for ITER's cryogenic network

    CERN Document Server

    Langeslag, S A E; Aviles Santillana, I; Sgobba, S; Foussat, A

    2015-01-01

    The development of new generation superconducting magnets for fusion research, such as the ITER experiment, is largely based on coils wound with so-called cable-in-conduit conductors. The concept of the cable-in-conduit conductor is based on a direct cooling principle, by supercritical helium, flowing through the central region of the conductor, in close contact with the superconducting strands. Consequently, a direct connection exists between the electrically grounded helium coolant supply line and the highly energised magnet windings. Various insulated regions, constructed out of high-voltage insulation breaks, are put in place to isolate sectors with different electrical potential. In addition to high voltages and significant internal helium pressure, the insulation breaks will experience various mechanical forces resulting from differential thermal contraction phenomena and electro-magnetic loads. Special test equipment was designed, prepared and employed to assess the mechanical reliability of the insul...

  1. Characterisation of the VELO High Voltage System

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L

    2008-01-01

    The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; vercation of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence th...

  2. Characterisation of the VELO High Voltage System

    CERN Document Server

    Rakotomiaramanana, B; Parkes, C; Eklund, L

    2008-01-01

    The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; verification of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence...

  3. High Voltage Distribution

    Science.gov (United States)

    Norbeck, Edwin; Miller, Michael; Onel, Yasar

    2010-11-01

    For detector arrays that require 5 to 10 kV at a few microamps each for hundreds of detectors, using hundreds of HV power supplies is unreasonable. Bundles of hundreds of HV cables take up space that should be filled with detectors. A typical HV module can supply 1 ma, enough current for hundreds of detectors. It is better to use a single HV module and distribute the current as needed. We show a circuit that, for each detector, measures the current, cuts off the voltage if the current exceeds a set maximum, and allows the HV to be turned on or off from a control computer. The entire array requires a single HV cable and 2 or 3 control lines. This design provides the same voltage to all of the detectors, the voltage set by the single HV module. Some additional circuitry would allow a computer controlled voltage drop between the HV and each individual detector.

  4. Design of load-to-failure tests of high-voltage insulation breaks for ITER's cryogenic network

    Science.gov (United States)

    Langeslag, S. A. E.; Rodriguez Castro, E.; Aviles Santillana, I.; Sgobba, S.; Foussat, A.

    2015-12-01

    The development of new generation superconducting magnets for fusion research, such as the ITER experiment, is largely based on coils wound with so-called cable-in-conduit conductors. The concept of the cable-in-conduit conductor is based on a direct cooling principle, by supercritical helium, flowing through the central region of the conductor, in close contact with the superconducting strands. Consequently, a direct connection exists between the electrically grounded helium coolant supply line and the highly energised magnet windings. Various insulated regions, constructed out of high-voltage insulation breaks, are put in place to isolate sectors with different electrical potential. In addition to high voltages and significant internal helium pressure, the insulation breaks will experience various mechanical forces resulting from differential thermal contraction phenomena and electro-magnetic loads. Special test equipment was designed, prepared and employed to assess the mechanical reliability of the insulation breaks. A binary test setup is proposed, where mechanical failure is assumed when leak rate of gaseous helium exceeds 10-9·Pa·m3/s. The test consists of a load-to-failure insulation break charging, in tension, while immersed in liquid nitrogen at the temperature of 77 K. Leak tightness during the test is monitored by measuring the leak rate of the gaseous helium, directly surrounding the insulation break, with respect to the existing vacuum inside the insulation break. The experimental setup is proven effective, and various insulation breaks performed beyond expectations.

  5. A fully enclosed, compact standard lightning impulse generator for testing ultra-high-voltage-class gas-insulated switchgears with high capacitance

    Science.gov (United States)

    Wen, Tao; Zhang, Qiaogen; Zhang, Lingli; Zhao, Junping; Liu, Xuandong; Li, Xiaoang; Guo, Can; You, Haoyang; Chen, Weijiang; Yin, Yu; Shi, Weidong

    2016-03-01

    At present, conducting standard lightning impulse (LI) tests in the field for gas-insulated switchgear (GIS) equipment is difficult because of the high capacitance of the test equipment and large circuit inductance of traditional impulse devices, which leads to a wavefront time Tf ≥ 2.5 μs. A novel fully enclosed, compact standard LI generator for testing ultra-high-voltage-class GIS equipment with high capacitance is presented to solve the problem of Tf exceeding the standard during LI voltage tests for actual large-sized equipment. The impulse generator is installed in a metal vessel filled with SF6 or SF6/N2 gas mixture at a pressure of 0.3-0.5 MPa, providing a more compact structure and a lower series inductance. A newly developed conical voltage sensor is used to accurately measure the output voltage waveform. Two test modes (via bushing docking and direct docking) for the GIS test based on the impulse generator are introduced. Calculation results show that the impulse generator can generate an LI test waveform following the present IEC standard for the test of equipment with capacitance >10 000 pF.

  6. General Consideration of Measuring System for Operational Test of Thyristor Valves of Ultra High Voltage DC Power Transmission

    Institute of Scientific and Technical Information of China (English)

    ZHOU Hui-gao; XU Fan; ZHANG Chang-chun; HU Zhi-long; LIU Pu; HUANG Xi-dong; WAN Gan; DING Qian

    2011-01-01

    Thyristor valve is one of the key equipments for ultra high voltage direct current (UHVDC)power transmission projects.Before being installed on site,they need to be tested in a laboratory in order to verify their operational performance to satisfy the technical specification of project related.Test facilities for operational tests of thyristor valves are supposed to enable to undertake more severe electrical stresses than those being applied in the thyristor valves under test (test objects).On the other hand,the stresses applied into the test objects are neither higher nor lower than specified by the specification,because inappropriate stresses applied would result in incorrect evaluation of performance on the test objects,more seriously,would cuase the damage of test objects with expensive cost losing.Generally,the process of operational tests is complicated and performed in a complex synthetic test circuit(hereafter as STC),where there are a lot of sensors used for measuring,monitoring and protection on line to ensure that the test circuit functions in good condition.Therefore,the measuring systems embedded play a core role in STC,acting like "eyes".Based on the first project of building up a STC in China,experience of planning measuring systems is summarized so as to be referenced by related engineers.

  7. Improvement and test of high power amplifier high voltage interlock circuit%高功放高压联锁电路改进与测试

    Institute of Scientific and Technical Information of China (English)

    金华松; 邱冬冬; 刘斯亮

    2012-01-01

    Whether the device can work regularly was determined by the performance of high voltage interlock directly. Through the operating principle analysis of high voltage interlock circuit and AC time delayer of high power amplifier based on CPI mechanical cabinet, an improved high voltage interlock circuit solution and a test method applied in AC time delayer are studied. The improved interlock circuit overcomes the drawbacks of original high voltage interlock solution. The designed test circuit can carry out quantitative test of AC time delayer parameters.%高压联锁性能的好坏直接影响设备能否正常工作.通过分析CPI高功放(HPA)的延时加高压程序、高压联锁电路和交流延时器工作原理,研究出一种新改选的高压联锁电路方案和用于交流延时器的测试方法.分析阐述表明,该方案和测试方法克服了CPI高功放的高压联锁方案的弊端.另外,根据分析结果设计了延时测试电路,它可对交流延时器性能参数进行定量测试.

  8. Optimal planning of series resistor to control time constant of test circuit for high-voltage AC circuit-breakers

    Directory of Open Access Journals (Sweden)

    Yoon-Ho Kim

    2016-01-01

    Full Text Available The equivalent test circuit that can deliver both short-circuit current and recovery voltage is used to verify the performance of high-voltage circuit breakers. Most of the parameters in this circuit can be obtained by using a simple calculation or a simulation program. The ratings of the circuit breaker include rated short-circuit breaking current, rated short-circuit making current, rated operating sequence of the circuit breaker and rated short-time current. Among these ratings, the short-circuit making capacity of the circuit breaker is expressed in peak value and not in RMS value similar to breaking capacity. A series resistor or super-excitation is used to control the peak value of the short-circuit current in the equivalent test circuit. When using a series resistor, a higher rating of circuit breakers leads to a higher thermal capacity, thereby requiring additional space. Therefore, an effective, optimal design of the series resistor is essential. This paper proposes a method for reducing thermal capacity and selecting the optimal resistance to limit the making current by controlling the DC time constant of the test circuit.

  9. Electronic Voltage and Current Transformers Testing Device

    Directory of Open Access Journals (Sweden)

    Yong Xiao

    2012-01-01

    Full Text Available A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz. The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware.

  10. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  11. Use of vacuum tubes in test instrumentation for measuring characteristics of fast high-voltage semiconductor devices

    Science.gov (United States)

    Berning, D.

    1981-01-01

    Circuits are described that permit measurement of fast events occurring in power semiconductors. These circuits were developed for the dynamic characterization of transistors used in inductive-load switching applications. Fast voltage clamping using vacuum diodes is discussed, and reference is made to a unique circuit that was built for performing nondestructive, reverse-bias, second-breakdown tests on transistors.

  12. First test of a high voltage feedthrough for liquid Argon TPCs connected to a 300 kV power supply

    CERN Document Server

    Cantini, C; Bueno, L Molina; Murphy, S; Radics, B; Regenfus, C; Rigaut, Y-A; Rubbia, A; Sergiampietri, F; Viant, T; Wu, S

    2016-01-01

    Voltages above a hundred kilo-volt will be required to generate the drift field of future very large liquid Argon Time Projection Chambers. The most delicate component is the feedthrough whose role is to safely deliver the very high voltage to the cathode through the thick insulating walls of the cryostat without compromising the purity of the argon inside. This requires a feedthrough that is typically meters long and carefully designed to be vacuum tight and have small heat input. Furthermore, all materials should be carefully chosen to allow operation in cryogenic conditions. In addition, electric fields in liquid argon should be kept below a threshold to reduce risks of discharges. The combination of all above requirements represents significant challenges from the design and manufacturing perspective. In this paper, we report on the successful operation of a feedthrough satisfying all the above requirements. The details of the feedthrough design and its manufacturing steps are provided. Very high voltages...

  13. Experimental validation of prototype high voltage bushing

    Science.gov (United States)

    Shah, Sejal; Tyagi, H.; Sharma, D.; Parmar, D.; M. N., Vishnudev; Joshi, K.; Patel, K.; Yadav, A.; Patel, R.; Bandyopadhyay, M.; Rotti, C.; Chakraborty, A.

    2017-08-01

    Prototype High voltage bushing (PHVB) is a scaled down configuration of DNB High Voltage Bushing (HVB) of ITER. It is designed for operation at 50 kV DC to ensure operational performance and thereby confirming the design configuration of DNB HVB. Two concentric insulators viz. Ceramic and Fiber reinforced polymer (FRP) rings are used as double layered vacuum boundary for 50 kV isolation between grounded and high voltage flanges. Stress shields are designed for smooth electric field distribution. During ceramic to Kovar brazing, spilling cannot be controlled which may lead to high localized electrostatic stress. To understand spilling phenomenon and precise stress calculation, quantitative analysis was performed using Scanning Electron Microscopy (SEM) of brazed sample and similar configuration modeled while performing the Finite Element (FE) analysis. FE analysis of PHVB is performed to find out electrical stresses on different areas of PHVB and are maintained similar to DNB HV Bushing. With this configuration, the experiment is performed considering ITER like vacuum and electrical parameters. Initial HV test is performed by temporary vacuum sealing arrangements using gaskets/O-rings at both ends in order to achieve desired vacuum and keep the system maintainable. During validation test, 50 kV voltage withstand is performed for one hour. Voltage withstand test for 60 kV DC (20% higher rated voltage) have also been performed without any breakdown. Successful operation of PHVB confirms the design of DNB HV Bushing. In this paper, configuration of PHVB with experimental validation data is presented.

  14. Design and Construction of a Test Bench to Characterize Efficiency and Reliability of High Voltage Battery Energy Storage Systems

    DEFF Research Database (Denmark)

    Blank, Tobias; Thomas, Stephan; Roggendorf, Christoph

    2010-01-01

    Stationary battery energy storage systems are widely used for uninterruptible power supply systems. Furthermore, they are able to provide grid services. This yields in rising installed power and capacity. One possibility uses high voltage batteries. This results in an improvement of the overall s...

  15. Design and Construction of a Test Bench to Characterize Efficiency and Reliability of High Voltage Battery Energy Storage Systems

    DEFF Research Database (Denmark)

    Blank, Tobias; Thomas, Stephan; Roggendorf, Christoph

    2010-01-01

    Stationary battery energy storage systems are widely used for uninterruptible power supply systems. Furthermore, they are able to provide grid services. This yields in rising installed power and capacity. One possibility uses high voltage batteries. This results in an improvement of the overall...

  16. The high voltage homopolar generator

    Science.gov (United States)

    Price, J. H.; Gully, J. H.; Driga, M. D.

    1986-11-01

    System and component design features of proposed high voltage homopolar generator (HVHPG) are described. The system is to have an open circuit voltage of 500 V, a peak output current of 500 kA, 3.25 MJ of stored inertial energy and possess an average magnetic-flux density of 5 T. Stator assembly components are discussed, including the stator, mount structure, hydrostatic bearings, main and motoring brushgears and rotor. Planned operational procedures such as monitoring the rotor to full speed and operation with a superconducting field coil are delineated.

  17. Transient voltage sharing in series-coupled high voltage switches

    Directory of Open Access Journals (Sweden)

    Editorial Office

    1992-07-01

    Full Text Available For switching voltages in excess of the maximum blocking voltage of a switching element (for example, thyristor, MOSFET or bipolar transistor such elements are often coupled in series - and additional circuitry has to be provided to ensure equal voltage sharing. Between each such series element and system ground there is a certain parasitic capacitance that may draw a significant current during high-speed voltage transients. The "open" switch is modelled as a ladder network. Analy­sis reveals an exponential progression in the distribution of the applied voltage across the elements. Overstressing thus oc­curs in some of the elements at levels of the total voltage that are significantly below the design value. This difficulty is overcome by grading the voltage sharing circuitry, coupled in parallel with each element, in a prescribed manner, as set out here.

  18. Advances in high voltage engineering

    CERN Document Server

    Haddad, A

    2005-01-01

    This book addresses the very latest research and development issues in high voltage technology and is intended as a reference source for researchers and students in the field, specifically covering developments throughout the past decade. This unique blend of expert authors and comprehensive subject coverage means that this book is ideally suited as a reference source for engineers and academics in the field for years to come.

  19. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    Science.gov (United States)

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  20. Voltage, Temperature, Frequency Margin Test Report

    DEFF Research Database (Denmark)

    Denver, Troelz

    1999-01-01

    The purpose of the tests is to establish the camera functionality when it is exposed to an extreme environment for prolonged periods, thus simulating the end of life performance. This environment covers temperature, input clock frequency and supply voltage variation......The purpose of the tests is to establish the camera functionality when it is exposed to an extreme environment for prolonged periods, thus simulating the end of life performance. This environment covers temperature, input clock frequency and supply voltage variation...

  1. Test setup for accelerated test of high power IGBT modules with online monitoring of Vce and Vf voltage during converter operation

    DEFF Research Database (Denmark)

    de Vega, Angel Ruiz; Ghimire, Pramod; Pedersen, Kristian Bonderup;

    2014-01-01

    of the device in real application. The hypothesis is that ageing of power modules closer to real environment including cooling system, full dc-link voltage and continuous PWM operation could lead to more accurate study of failure mechanism. A new type of test setup is proposed, which can create different real...

  2. High voltage source control on FODS

    Science.gov (United States)

    Patalakha, D. I.; Kalinin, A. Yu; Kulagin, N. V.

    2017-01-01

    The implementation of the high voltage power supply control system (HVPSCS) for experimental setup FODS (FOcusing Doublearmed Spectrometer) at accelerator U-70 of the Federal State Budgetary Institution State Research Center Of Russia Institute for High Energy Physics of the National Research Centre “Kurchatov Institute” (hereinafter referred to as IHEP) or for the test bench of the detector components is considered. The required set of hardware is defined and the appropriate software to operate HVPSCS is written in C/C++ codes. The date acquisition (DAQ) system [1] makes automatic control on HVPSCS for data taking run. It allows to get the dependence of appropriate detector parameters on the high voltage supply values and choose its optimal values for FODS detectors. The test run results of HVPSCS are presented.

  3. Isolated Fast High-Voltage Switching Circuit

    Science.gov (United States)

    Rizzi, Anthony

    1992-01-01

    Electrically isolated switching circuit supplies pulses at potentials up to 6.5 kV and currents up to 6.5 A, lasting as long as few microseconds. Turn-on time about 40 ns; turn-off time about 3 microseconds. Electrically isolated from control circuitry by means of fiber-optic signal coupling and isolated power supply. Electrical isolation protects both technician and equipment. This and similar circuits useful in such industrial and scientific applications as high-voltage, high-frequency test equipment; electrostatic-discharge test equipment; plasma-laboratory instrumentation; spark chambers; and electromagnetic-interference test equipment.

  4. High voltage load resistor array

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  5. High voltage pulse generator. [Patent application

    Science.gov (United States)

    Fasching, G.E.

    1975-06-12

    An improved high-voltage pulse generator is described which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of the first rectifier connected between the first and second capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. The output voltage can be readily increased by adding additional charging networks. The circuit allows the peak level of the output to be easily varied over a wide range by using a variable autotransformer in the charging circuit.

  6. Developement of new measuring techniques. A measuring system for testing GIS disconnectors in a high voltage laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Carubelli, C.; Cremonesi, F.; Santagostino, G.

    1988-10-01

    Within the framework of the cooperation between CESI (Italy) and the CPRI (Central Power Research Institute), the problem of a fast and accurate measurements systems for gas-insulated substations (GIS) disconnector testing was analyzed. The particular complexity of the transients to be studied has led to the development of a composite system in which the high frequency components are dealt with by analog techniques and medium frequency components are handled with digital techniques. Sophisticate software was developed to combine the measurement results. Further improvements are expected with the development of a fiber-optics link with an extended bandwidth and the adoption of a digital oscilloscope in order to simplify the overall management of the tests.

  7. COTS Li-Ion Cells in High Voltage Batteries

    Science.gov (United States)

    Davies, Francis; Darcy, Eric; Jeevarajan, Judy; Cowles, Phil

    2003-01-01

    Testing at NASA JSC and COMDEV shows that Commercial Off the Shelf (COTS) Li Ion cells can not be used in high voltage batteries safely without considering the voltage stresses that may be put on the protective devices in them during failure modes.

  8. Compact, Lightweight, High Voltage Propellant Isolators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  9. Compact, Lightweight, High Voltage Propellant Isolators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  10. High voltage electricity installations a planning perspective

    CERN Document Server

    Jay, Stephen Andrew

    2006-01-01

    The presence of high voltage power lines has provoked widespread concern for many years. High Voltage Electricity Installations presents an in-depth study of policy surrounding the planning of high voltage installations, discussing the manner in which they are percieved by the public, and the associated environmental issues. An analysis of these concerns, along with the geographical, environmental and political influences that shape their expression, is presented. Investigates local planning policy in an area of the energy sector that is of highly topical environmental and public concern Cover

  11. Radiatively heated high voltage pyroelectric crystal pulser

    Energy Technology Data Exchange (ETDEWEB)

    Antolak, A.J., E-mail: antolak@sandia.gov [Sandia National Laboratories, Livermore, CA 94550 (United States); Chen, A.X. [Sandia National Laboratories, Livermore, CA 94550 (United States); Leung, K.-N. [Sandia National Laboratories, Livermore, CA 94550 (United States); Nuclear Engineering Department, University of California, Berkeley (United States); Morse, D.H.; Raber, T.N. [Sandia National Laboratories, Livermore, CA 94550 (United States)

    2014-01-21

    Thin lithium tantalate pyroelectric crystals in a multi-stage pulser were heated by quartz lamps during their charging phase to generate high voltage pulses. The charging voltage was determined empirically based on the measured breakdown voltage in air and verified by the induced breakdown voltage of an external high voltage power supply. A four-stage pyroelectric crystal device generated pulse discharges of up to 86 kV using both quartz lamps (radiative) and thermoelectric (conductive) heating. Approximately 50 mJ of electrical energy was harvested from the crystals when radiatively heated in air, and up to 720 mJ was produced when the crystals were submerged in a dielectric fluid. It is anticipated that joule-level pulse discharges could be obtained by employing additional stages and optimizing the heating configuration.

  12. Safe epoxy encapsulant for high voltage magnetics

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, R.O.; Archer, W.E.

    1998-01-01

    This paper describes the use of Formula 456, an aliphatic amine cured epoxy for impregnating coils and high voltage transformers. Sandia has evaluated a number of MDA-free epoxy encapsulants which relied on either anhydride or other aromatic amine curing agents. The use of aliphatic amine curing agents was more recently evaluated and has resulted in the definition of Formula 456 resin. Methylene dianiline (MDA) has been used for more than 20 years as the curing agent for various epoxy formulations throughout the Department of Energy and much of industry. Sandia National Laboratories began the process of replacing MDA with other formulations because of regulations imposed by OSHA on the use of MDA. OSHA has regulated MDA because it is a suspect carcinogen. Typically the elimination of OSHA-regulated materials provides a rare opportunity to qualify new formulations in a range of demanding applications. It was important to take full advantage of that opportunity, although the associated materials qualification effort was costly. Small high voltage transformers are one of those demanding applications. The successful implementation of the new formulation for high reliability transformers will be described. The test results that demonstrate the parts are qualified for use in DOE weapon systems will be presented.

  13. High voltage and electrical insulation engineering

    CERN Document Server

    Arora, Ravindra

    2011-01-01

    "The book is written for students as well as for teachers and researchers in the field of High Voltage and Insulation Engineering. It is based on the advance level courses conducted at TU Dresden, Germany and Indian Institute of Technology Kanpur, India. The book has a novel approach describing the fundamental concept of field dependent behavior of dielectrics subjected to high voltage. There is no other book in the field of high voltage engineering following this new approach in describing the behavior of dielectrics. The contents begin with the description of fundamental terminology in the subject of high voltage engineering. It is followed by the classification of electric fields and the techniques of field estimation. Performance of gaseous, liquid and solid dielectrics under different field conditions is described in the subsequent chapters. Separate chapters on vacuum as insulation and the lightning phenomenon are included"--

  14. Steady state tests of high voltage ceramic feedthroughs and co-axial transmission line of ICRF heating system for the Large Helical Device

    Energy Technology Data Exchange (ETDEWEB)

    Mutoh, Takashi; Kumazawa, Ryuhei; Seki, Tetsuo; Simpo, Fujio; Nomura, Goro; Ido, Tsuyoshi; Watari, Tetsuo [National Inst. for Fusion Science, Toki, Gifu (Japan); Norterdaeme, J.M.

    1998-06-01

    Steady state ICRF heating technologies have been developed to heat plasma for more than 30 minutes in the LHD. Steady state operation tests of high voltage up to 40 kV{sub OP} for more than 30 minutes were carried out on the RF vacuum feedthroughs and the co-axial transmission line in the test set. Four types of ceramic feedthroughs each having a diameter of 240 mm were tested. The cone-type alumina ceramic and the cylinder-type silicon nitride composite-ceramic feedthroughs produced good performances of 40 kV/30 minutes and 50 kV/10 seconds. The others had vacuum leaks when subjected to a long pulse duration. The temperature of the cone-type alumina ceramic feedthrough was measured during the ICRF operations. By using gas-cooling techniques, the temperature increase of the ceramic was substantially reduced and saturated within 20 minutes. Without gas-cooling, the temperature increased linearly and did not saturated. So, this approach could not be used for steady state. The RF dissipation on the ceramic was calculated using the finite element computer code (ANSYS). It was found that damaged feedthroughs had local high heat spots, which could result in vacuum leaks. A water-cooled co-axial transmission line of 240 mm diameter was designed and tested. The specially designed connector components and Teflon insulator disks were tested. During the test, the insulation gases of nitrogen, sulfur hexafluoride and carbon dioxide were used to compare the capability of insulation for steady state. For the duration of a 10-second pulse, these gases performed well up to 60 kV{sub OP}. However, for steady state operation, carbon dioxide gas could not withstand voltages above 40 kV{sub OP}. The connector components of the transmission line performed without problems below 50 kV{sub OP} and 1 kA{sub OP} for a 30-minute operation. The performance of the feedthroughs and transmission line exceeded the specifications for steady state heating in the LHD. (J.P.N.)

  15. Programmable high voltage power supply with regulation confined to the high voltage section

    Science.gov (United States)

    Castell, Karen D. (Inventor); Ruitberg, Arthur P. (Inventor)

    1994-01-01

    A high voltage power supply in a dc-dc converter configuration includes a pre-regulator which filters and regulates the dc input and drives an oscillator which applies, in turn, a low voltage ac signal to the low side of a step-up high voltage transformer. The high voltage side of the transformer drives a voltage multiplier which provides a stepped up dc voltage to an output filter. The output voltage is sensed by a feedback network which then controls a regulator. Both the input and output of the regulator are on the high voltage side, avoiding isolation problems. The regulator furnishes a portion of the drive to the voltage multiplier, avoiding having a regulator in series with the load with its attendant, relatively high power losses. This power supply is highly regulated, has low power consumption, a low parts count and may be manufactured at low cost. The power supply has a programmability feature that allows for the selection of a large range of output voltages.

  16. Integration Tests of the 4 kW-Class High Voltage Hall Accelerator Power Processing Unit with the HiVHAc and the SPT-140 Hall Effect Thrusters

    Science.gov (United States)

    Kamhawi, Hani; Pinero, Luis; Haag, Thomas; Huang, Wensheng; Ahern, Drew; Liang, Ray; Shilo, Vlad

    2016-01-01

    NASA's Science Mission Directorate is sponsoring the development of a 4 kW-class Hall propulsion system for implementation in NASA science and exploration missions. The main components of the system include the High Voltage Hall Accelerator (HiVHAc), an engineering model power processing unit (PPU) developed by Colorado Power Electronics, and a xenon flow control module (XFCM) developed by VACCO Industries. NASA Glenn Research Center is performing integrated tests of the Hall thruster propulsion system. This paper presents results from integrated tests of the PPU and XFCM with the HiVHAc engineering development thruster and a SPT-140 thruster provided by Space System Loral. The results presented in this paper demonstrate thruster discharge initiation along with open-loop and closed-loop control of the discharge current with anode flow for both the HiVHAc and the SPT-140 thrusters. Integrated tests with the SPT-140 thruster indicated that the PPU was able to repeatedly initiate the thruster's discharge, achieve steady state operation, and successfully throttle the thruster between 1.5 and 4.5 kW. The measured SPT-140 performance was identical to levels reported by Space Systems Loral.

  17. 76 FR 70721 - Voltage Coordination on High Voltage Grids; Notice of Staff Workshop

    Science.gov (United States)

    2011-11-15

    ... Energy Regulatory Commission Voltage Coordination on High Voltage Grids; Notice of Staff Workshop Take notice that the Federal Energy Regulatory Commission will hold a Workshop on Voltage Coordination on High Voltage Grids on Thursday, December 1, 2011 from 9 a.m. to 4:30 p.m. This staff-led workshop will be...

  18. Modeling of long High Voltage AC Underground

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Bak, Claus Leth; Wiechowski, W. T.

    2010-01-01

    This paper presents the work and findings of a PhD project focused on accurate high frequency modelling of long High Voltage AC Underground cables. The project is cooperation between Aalborg University and Energinet.dk. The objective of the project is to investigate the accuracy of most up to date...

  19. Reliability and Characterization of High Voltage Power Capacitors

    Science.gov (United States)

    2014-03-01

    ix LIST OF FIGURES Figure 1.   System level overview of IPC EVCS (from [3]). ..............................................2   Figure 2...permittivity EVCS electric vehicle charging system GPIB general-purpose interface bus GW giga-watt HVST high voltage stress test IV current voltage...Power Converter (IPC). This converter is being used for the Electric Vehicle Charging Station ( EVCS ), currently being investigated and installed in

  20. High voltage pulsed cable design: a practical example

    Energy Technology Data Exchange (ETDEWEB)

    Kewish, R.W. Jr.; Boicourt, G.P.

    1979-01-01

    The design of optimum high voltage pulse cable is difficult because very little emperical data are available on performance in pulsed applications. This paper follows the design and testing of one high voltage pulse cable, 40/100 trigger cable. The design was based on an unproven theory and the impressive outcome lends support to the theory. The theory is outlined and it is shown that there exists an inductance which gives a cable of minimum size for a given maximum stress. Test results on cable manufactured according to the design are presented and compared with the test results on the cable that 40/100 replaces.

  1. High Input Voltage, Silicon Carbide Power Processing Unit Performance Demonstration

    Science.gov (United States)

    Bozak, Karin E.; Pinero, Luis R.; Scheidegger, Robert J.; Aulisio, Michael V.; Gonzalez, Marcelo C.; Birchenough, Arthur G.

    2015-01-01

    A silicon carbide brassboard power processing unit has been developed by the NASA Glenn Research Center in Cleveland, Ohio. The power processing unit operates from two sources: a nominal 300 Volt high voltage input bus and a nominal 28 Volt low voltage input bus. The design of the power processing unit includes four low voltage, low power auxiliary supplies, and two parallel 7.5 kilowatt (kW) discharge power supplies that are capable of providing up to 15 kilowatts of total power at 300 to 500 Volts (V) to the thruster. Additionally, the unit contains a housekeeping supply, high voltage input filter, low voltage input filter, and master control board, such that the complete brassboard unit is capable of operating a 12.5 kilowatt Hall effect thruster. The performance of the unit was characterized under both ambient and thermal vacuum test conditions, and the results demonstrate exceptional performance with full power efficiencies exceeding 97%. The unit was also tested with a 12.5kW Hall effect thruster to verify compatibility and output filter specifications. With space-qualified silicon carbide or similar high voltage, high efficiency power devices, this would provide a design solution to address the need for high power electric propulsion systems.

  2. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F.; Yee, Daniel D.

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  3. Planar multijunction high voltage solar cells

    Science.gov (United States)

    Evans, J. C., Jr.; Chai, A. T.; Goradia, C.

    1980-01-01

    Technical considerations, preliminary results, and fabrication details are discussed for a family of high-voltage planar multi-junction (PMJ) solar cells which combine the attractive features of planar cells with conventional or interdigitated back contacts and the vertical multijunction (VMJ) solar cell. The PMJ solar cell is internally divided into many voltage-generating regions, called unit cells, which are internally connected in series. The key to obtaining reasonable performance from this device was the separation of top surface field regions over each active unit cell. Using existing solar cell fabricating methods, output voltages in excess of 20 volts per linear centimeter are possible. Analysis of the new device is complex, and numerous geometries are being studied which should provide substantial benefits in both normal sunlight usage as well as with concentrators.

  4. The VELO High Voltage System Control Software

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L; De Capua, S

    2010-01-01

    This note describes the VELO high voltage control software. The implementation of its structure as a PVSS Finite State Machine is emphasized. The main error conditions that may occur during operation is also discussed. The VELO HV software conforms to the specification of the VELO.

  5. An Inexpensive Source of High Voltage

    Science.gov (United States)

    Saraiva, Carlos

    2012-01-01

    As a physics teacher I like recycling old apparatus and using them for demonstrations in my classes. In physics laboratories in schools, sources of high voltage include induction coils or electronic systems that can be bought from companies that sell lab equipment. But these sources can be very expensive. In this article, I will explain how you…

  6. Improved Lifetime High Voltage Switch Electrode.

    Science.gov (United States)

    2014-09-26

    capabilities of spark switches (e.g., saturable magnetic reactors, ignitions, and high power vacuum tubes), none has the combined high voltage, high...series impedance of the switch . Additionally, the eroded material may be deposited on internal insulators , thereby inducing pretriggering and erratic...of dry air, a typical spark switch insulating gas. -7- ENERGETIC IONS FROM ION IMPLANTER 0 0 0 0 -0 0 00000 0 0 oSUBSTRATE 0 - 0 o 0 SAMPLE= ’ 0• 0 U 0

  7. High Voltage Test Apparatus for a Neutron EDM Experiment and Lower Limit on the Dielectric Strength of Liquid Helium at Large Volumes

    CERN Document Server

    Long, J C; Boissevain, J G; Clark, D J; Cooper, M D; Gómez, J J; Lamoreaux, S K; Mischke, R E; Penttila, S I

    2006-01-01

    A new search for a permanent electric dipole moment (EDM) of the neutron is underway using ultracold neutrons produced and held in a bath of superfluid helium. Attaining the target sensitivity requires maintaining an electric field of several tens of kilovolts per centimeter across the experimental cell, which is nominally 7.5 cm wide and will contain about 4 liters of superfluid. The electrical properties of liquid helium are expected to be sufficient to meet the design goals, but little is known about these properties for volumes and electrode spacings appropriate to the EDM experiment. Furthermore, direct application of the necessary voltages from an external source to the experimental test cell is impractical. An apparatus to amplify voltages in the liquid helium environment and to test the electrical properties of the liquid for large volumes and electrode spacings has been constructed. The device consists of a large-area parallel plate capacitor immersed in a 200 liter liquid helium dewar. Preliminary r...

  8. 30 CFR 75.804 - Underground high-voltage cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage cables. 75.804 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.804 Underground high-voltage cables. (a) Underground high-voltage cables used in resistance...

  9. 30 CFR 77.810 - High-voltage equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage equipment; grounding. 77.810... COAL MINES Surface High-Voltage Distribution § 77.810 High-voltage equipment; grounding. Frames, supporting structures, and enclosures of stationary, portable, or mobile high-voltage equipment shall...

  10. High Voltage Test Power’s Fast Cutting-off Device Based on Infrared%基于红外线的高压试验电源快速切断装置

    Institute of Scientific and Technical Information of China (English)

    胡双双; 周刚; 胡海平; 邱东晓; 金海; 潘克菲

    2015-01-01

    High voltage power system during the test will generate tens of kilovolts or more high-pressure. Therefore,to ensure the safety of persons and equipment is a basic requirement.However,approaches of the traditional use of ropes or fence to seclude the high voltage test area can not protect the safety of personnel and equipment at the root when testing personnel or foreign body mistakenly go in the charged region.This paper presented a program of fast high voltage test power cut-off device based on infrared.It can make audible voice alarm,at the same time quickly cut off high voltage power supply,to ensure the safety of persons and equipment from the source,when testing personnel or foreign objects mistakenly go in the charged region.%提出了一种基于红外线的高压试验电源快速切断的方案,并设计了装置的硬件电路和系统软件。经现场试验,当有人员或异物误入带电区域时,发出声光语音报警的同时快速切断高压电源,从源头上保证人身和设备安全。

  11. High Voltage Design Guide. Volume V. Spacecraft

    Science.gov (United States)

    1983-01-01

    connector are soldered, with the possible exception of very high voltage points. Even then rudimentary connectors such as that shown In figura 13 ar used...addition, large stresses will be imposed on the struc- tural (high resistance) member. This conductor movement will flex and stretch the conductors, placing...materials used for airplane systems provided they meet the electrical, chemical, and mechanical characteristic requirements imposed by the design

  12. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    , and remote power generation for light towers, camper vans, boats, beacons, and buoys etc. A review of current state-of-the-art is presented. The best performing converters achieve moderately high peak efficiencies at high input voltage and medium power level. However, system dimensioning and cost are often......The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based...... determined by the performance at the system worst case operating point which is usually at minimum input voltage and maximum power. Except for the non-regulating V6 converters, all published solutions exhibit a very significant drop in conversion efficiency at minimum input voltage and maximum output power...

  13. A high voltage programmable ramp generator

    Science.gov (United States)

    Upadhyay, J.; Joshi, M. J.; Deshpande, P. P.; Sharma, M. L.; Navathe, C. P.

    2008-05-01

    In this paper, a ramp generator with programmable slope is presented. It consists of a high voltage step generator, followed by integrator. The capacitor and inductor in the integrator are designed such that they can be varied by a microcontroller. This circuit generates two bipolar ramps with fastest speed <1ns and provides continuous speed variation from 6to30ns for a ramp of 500V. This is being developed as a part of automated streak camera for deflection of electron beam.

  14. Electric Insulation Detection Method for High-voltage Insulators

    Directory of Open Access Journals (Sweden)

    Wang Jiajun

    2013-07-01

    Full Text Available The principle of partial discharge detection is that through partial bridged discharge under high voltage electric field, it detects the inner air-filled cavity of high-voltage insulators. And it is a nondestructive detection method based on discharge magnitude to judge the insulation quality. The detecting system that adopts the partial discharge detection is more rigorous than testing system for electricity products, which must have small discharge capacity and higher sensitivity. This paper describes the principles of partial discharge detection and analysis insulation detection.

  15. High-voltage live cleaning robot design based on security

    Institute of Scientific and Technical Information of China (English)

    XIE Xiao-peng; XIA Hong-wei; YANG Ru-qing

    2005-01-01

    High-Voltage Live Cleaning Robot works in a hot-line environment (220 kV/330 kV), and so the safety of its application and equipment is most important. In terms of safety, the designs of robot mechanism and control system have been discussed, and the test data are given regarding the control system of a model machine. The model machine of a high-voltage live cleaning robot can satisfy the needs of basic cleaning in common conditions. From manual operation to automation, the cleaning efficiency is improved. The robot can decrease the amount of work, and guarantee security. Among high-voltage live cleaning equipment in China, the cleaning robot is advanced in automation and intelligence.

  16. Implementation of an outline of transformer induced voltage tests

    Directory of Open Access Journals (Sweden)

    Orestes Hernández Areu

    2010-02-01

    Full Text Available The results of the developed work for the implementation of the induced voltage test to be applied to single phase distribution transformers in the Researches and Electroenergetic Tests Center (CIPEL of Cuba, are presented, The test outline was obtained starting from the employment of a motor - generator group, with an external voltage regulator and using a frequency converter to obtain the necessary frequency for this type of test.

  17. High Voltage in Noble Liquids for High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Rebel, B. [Fermilab; Bernard, E. [Yale U.; Faham, C. H. [LBL, Berkeley; Ito, T. M. [Los Alamos; Lundberg, B. [Maryland U.; Messina, M. [Columbia U.; Monrabal, F. [Valencia U., IFIC; Pereverzev, S. P. [LLNL, Livermore; Resnati, F. [Zurich, ETH; Rowson, P. C. [SLAC; Soderberg, M. [Fermilab; Strauss, T. [Bern U.; Tomas, A. [Imperial Coll., London; Va' vra, J. [SLAC; Wang, H. [UCLA

    2014-08-22

    A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at developing high voltage systems in noble liquids.

  18. Maintenance Optimization of High Voltage Substation Model

    Directory of Open Access Journals (Sweden)

    Jan Gala

    2008-01-01

    Full Text Available The real system from practice is selected for optimization purpose in this paper. We describe the real scheme of a high voltage (HV substation in different work states. Model scheme of the HV substation 22 kV is demonstrated within the paper. The scheme serves as input model scheme for the maintenance optimization. The input reliability and cost parameters of all components are given: the preventive and corrective maintenance costs, the actual maintenance period (being optimized, the failure rate and mean time to repair - MTTR.

  19. History of high-voltage ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Singer, E.

    In principle, the feldspar porcelain used for making tableware way back in the 18th century already would have been good enough for electrical purposes, especially for making high-voltage insulators. Thus, further advances in that sector were made for reasons of economy and better process engineering. This would include things like improving the material's green workability. Then, in 1918, Gilchrist and Klinefelter called attention to property changes in the raw materials triangle kaolinquartz-feldspar. Additional glass matrix increases the finished material's dielectric strength, while a larger share of kaolin improves its heat resistance, and a mixture of quartz and feldspar adds more strength.

  20. High-Voltage, Low-Power BNC Feedthrough Terminator

    Science.gov (United States)

    Bearden, Douglas

    2012-01-01

    This innovation is a high-voltage, lowpower BNC (Bayonet Neill-Concelman) feedthrough that enables the user to terminate an instrumentation cable properly while connected to a high voltage, without the use of a voltage divider. This feedthrough is low power, which will not load the source, and will properly terminate the instrumentation cable to the instrumentation, even if the cable impedance is not constant. The Space Shuttle Program had a requirement to measure voltage transients on the orbiter bus through the Ground Lightning Measurement System (GLMS). This measurement has a bandwidth requirement of 1 MHz. The GLMS voltage measurement is connected to the orbiter through a DC panel. The DC panel is connected to the bus through a nonuniform cable that is approximately 75 ft (approximately equal to 23 m) long. A 15-ft (approximately equal to 5-m), 50-ohm triaxial cable is connected between the DC panel and the digitizer. Based on calculations and simulations, cable resonances and reflections due to mismatched impedances of the cable connecting the orbiter bus and the digitizer causes the output not to reflect accurately what is on the bus. A voltage divider at the DC panel, and terminating the 50-ohm cable properly, would eliminate this issue. Due to implementation issues, an alternative design was needed to terminate the cable properly without the use of a voltage divider. Analysis shows how the cable resonances and reflections due to the mismatched impedances of the cable connecting the orbiter bus and the digitizer causes the output not to reflect accurately what is on the bus. After simulating a dampening circuit located at the digitizer, simulations were performed to show how the cable resonances were dampened and the accuracy was improved significantly. Test cables built to verify simulations were accurate. Since the dampening circuit is low power, it can be packaged in a BNC feedthrough.

  1. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  2. High-Voltage, Asymmetric-Waveform Generator

    Science.gov (United States)

    Beegle, Luther W.; Duong, Tuan A.; Duong, Vu A.; Kanik, Isik

    2008-01-01

    The shapes of waveforms generated by commercially available analytical separation devices, such as some types of mass spectrometers and differential mobility spectrometers are, in general, inadequate and result in resolution degradation in output spectra. A waveform generator was designed that would be able to circumvent these shortcomings. It is capable of generating an asymmetric waveform, having a peak amplitude as large as 2 kV and frequency of several megahertz, which can be applied to a capacitive load. In the original intended application, the capacitive load would consist of the drift plates in a differential-mobility spectrometer. The main advantage to be gained by developing the proposed generator is that the shape of the waveform is made nearly optimum for various analytical devices requiring asymmetric-waveform such as differential-mobility spectrometers. In addition, this waveform generator could easily be adjusted to modify the waveform in accordance with changed operational requirements for differential-mobility spectrometers. The capacitive nature of the load is an important consideration in the design of the proposed waveform generator. For example, the design provision for shaping the output waveform is based partly on the principle that (1) the potential (V) on a capacitor is given by V=q/C, where C is the capacitance and q is the charge stored in the capacitor; and, hence (2) the rate of increase or decrease of the potential is similarly proportional to the charging or discharging current. The proposed waveform generator would comprise four functional blocks: a sine-wave generator, a buffer, a voltage shifter, and a high-voltage switch (see Figure 1). The sine-wave generator would include a pair of operational amplifiers in a feedback configuration, the parameters of which would be chosen to obtain a sinusoidal timing signal of the desired frequency. The buffer would introduce a slight delay (approximately equal to 20 ns) but would otherwise

  3. High perfomance selectable value transportable high dc Voltage standard

    CERN Document Server

    Galliana, Flavio; Tet, Luca Roncaglione

    2016-01-01

    At National Institute of Metrological Research (INRIM), a selectable-value Transportable High dcVoltage Standard (THVS) operating in the range from 10 V to 100 V in steps of 10 V, was developed. This Standard was built to cover the lack of high level dc Voltage Standards at voltages higher than 10 V to employ as laboratory (local) or travelling Standards for Inter-Laboratory Comparisons (ILCs). A ground-mobile electronic technique was used to enhance the accuracy of the THVS at the higher values. The THVS shows better noise, better short-mid-term stability than top level dc Voltage and multifunction calibrators (MFCs) and better suitability and insensibility to be transported than these instruments. The project is extensible to 1000 V.

  4. Development of a Remote Insulation Test Device for High-Voltage Electrical Motors%一种远程高压电机绝缘测试装置的开发研究

    Institute of Scientific and Technical Information of China (English)

    何锁侠; 佟洪明; 肖骥; 李开寒

    2014-01-01

    介绍了一种远程高压电机绝缘测试装置。根据系统需求,独自研发了一种加入了RS-485通信模块和控制模块的新一代电子式电阻表。基于西门子S7-200型PLC对高压电机绝缘监测设备、高压继电器、机械抓进行控制。建立了触摸屏、PLC、绝缘检测仪之间的通讯,实现了高压电机绝缘的远程测量功能。通过运用本装置,提高了高压电机绝缘检测的自动化水平,降低了设备维修频率,并保障了工人的人身安全。%A remote insulation test device for high -voltage electrical motors is introduced. To meet system requirement, a new -generation electronic insulation tester incorporating RS -485 communication module and control module was independently developed. Based on Siemens S7-200 PLC the system can control high-voltage motor insulation monitoring devices, high voltage relays and mechanical grips. Communication between the touch screen, PLC and insulation tester was established, realizing remote insulation measurement for high voltage motors. The device improves the automation level of high-voltage motor insulation test, reduces the frequency of equipment maintenance and ensures personal safety.

  5. Optimal planning of high voltage distribution substations

    Institute of Scientific and Technical Information of China (English)

    YU Yixin; YAN Xuefei; ZHANG Yongwu

    2007-01-01

    Aimed at solving the problem of optimal planning for high voltage distribution substations,an efficient method is put forward.The method divides the problem into two sub-problems:source locating and combinational optimization.The algorithm of allocating and locating alternatively (ALA) is widely used to deal with the source locating problem,but it is dependent on the initial location to a large degree.Thus,some modifications were made to the ALA algorithm,which could greatly improve the quality of solutions.In addition,considering the non-convex and nonconcave nature of the sub-problem of combinational optimization,the branch-and-bound technique was adopted to obtain or approximate a global optimal solution.To improve the efficiency of the branch-and-bound technique,some heuristic principles were proposed to cut those branches that may generate a global optimization solution with low probability.Examples show that the proposed algorithm meets the requirement of engineering and it is an effective approach to rapidly solve the problem of optimal planning for high voltage distribution substations.

  6. Program-Controlled High Voltage Module in Active Voltage Dividers(AVD) for MPGD

    CERN Document Server

    Ginting, Muhammad Fadhil

    2016-01-01

    Micro Pattern Gas Detectors (MPGD) applications are rapidly developing and became an important part of upgrades for the LHC detectors. RD51/CERN have worked on Active Voltage Divider (AVD) technology for multistage MPGDs, One of the next developments for the AVD is to design and integrate high voltage module in a single box. The Program-Controlled High Voltage Module, part of one AIDA2020 project, has been successfully designed and developed, and can be integrated in AVD design.

  7. High Voltage Power Transmission for Wind Energy

    Science.gov (United States)

    Kim, Young il

    The high wind speeds and wide available area at sea have recently increased the interests on offshore wind farms in the U.S.A. As offshore wind farms become larger and are placed further from the shore, the power transmission to the onshore grid becomes a key feature. Power transmission of the offshore wind farm, in which good wind conditions and a larger installation area than an onshore site are available, requires the use of submarine cable systems. Therefore, an underground power cable system requires unique design and installation challenges not found in the overhead power cable environment. This paper presents analysis about the benefit and drawbacks of three different transmission solutions: HVAC, LCC/VSC HVDC in the grid connecting offshore wind farms and also analyzed the electrical characteristics of underground cables. In particular, loss of HV (High Voltage) subsea power of the transmission cables was evaluated by the Brakelmann's theory, taking into account the distributions of current and temperature.

  8. High Voltage GaN Schottky Rectifiers

    Energy Technology Data Exchange (ETDEWEB)

    CAO,X.A.; CHO,H.; CHU,S.N.G.; CHUO,C.-C.; CHYI,J.-I.; DANG,G.T.; HAN,JUNG; LEE,C.-M.; PEARTON,S.J.; REN,F.; WILSON,R.G.; ZHANG,A.P.

    1999-10-25

    Mesa and planar GaN Schottky diode rectifiers with reverse breakdown voltages (V{sub RB}) up to 550V and >2000V, respectively, have been fabricated. The on-state resistance, R{sub ON}, was 6m{Omega}{center_dot} cm{sup 2} and 0.8{Omega}cm{sup 2}, respectively, producing figure-of-merit values for (V{sub RB}){sup 2}/R{sub ON} in the range 5-48 MW{center_dot}cm{sup -2}. At low biases the reverse leakage current was proportional to the size of the rectifying contact perimeter, while at high biases the current was proportional to the area of this contact. These results suggest that at low reverse biases, the leakage is dominated by the surface component, while at higher biases the bulk component dominates. On-state voltages were 3.5V for the 550V diodes and {ge}15 for the 2kV diodes. Reverse recovery times were <0.2{micro}sec for devices switched from a forward current density of {approx}500A{center_dot}cm{sup -2} to a reverse bias of 100V.

  9. High-frequency graphene voltage amplifier.

    Science.gov (United States)

    Han, Shu-Jen; Jenkins, Keith A; Valdes Garcia, Alberto; Franklin, Aaron D; Bol, Ageeth A; Haensch, Wilfried

    2011-09-14

    While graphene transistors have proven capable of delivering gigahertz-range cutoff frequencies, applying the devices to RF circuits has been largely hindered by the lack of current saturation in the zero band gap graphene. Herein, the first high-frequency voltage amplifier is demonstrated using large-area chemical vapor deposition grown graphene. The graphene field-effect transistor (GFET) has a 6-finger gate design with gate length of 500 nm. The graphene common-source amplifier exhibits ∼5 dB low frequency gain with the 3 dB bandwidth greater than 6 GHz. This first AC voltage gain demonstration of a GFET is attributed to the clear current saturation in the device, which is enabled by an ultrathin gate dielectric (4 nm HfO(2)) of the embedded gate structures. The device also shows extrinsic transconductance of 1.2 mS/μm at 1 V drain bias, the highest for graphene FETs using large-scale graphene reported to date.

  10. Review on Out-Of-Phase Making and Breaking Test Method of High-Voltage Circuit Breaker%高压断路器失步开合试验方法的评述

    Institute of Scientific and Technical Information of China (English)

    吴盛刚; 张建新; 赵建沛; 王鹏飞; 周跃刚

    2013-01-01

    Description was made to the multiple test circuits and the test conditions of high-voltage circuit breakers in carrying out out-of-phase making and breaking test and comparison was made to their advantages and disadvantages. According to the actual test conditions in test station, this paper selected transformer double-circuit which is convenient to carry out and parallel voltage injec-tion circuit and calculated parameters of 126 kV level test loop. Simulation was carried out for the relevant transient recovery voltage waveforms. The result is in conformity with the expected requirements, so it can be implemented.%阐述了高压断路器进行失步开合试验的多种试验线路及其试验条件,并比较了各自的优缺点。根据试验站的具体设备条件,选取了便于实施的变压器双联电路和并联电压引入回路,并计算了126 kV级试验回路的参数,对相应的瞬态恢复电压TRV波形进行了仿真,其结果符合预期要求,故可以实施。

  11. Transformerless DC-DC Converter Using Cockcroft-Walton Voltage Multiplier to Obtain High DC Voltage

    Directory of Open Access Journals (Sweden)

    Meghana G Naik,

    2014-11-01

    Full Text Available In the present scenario the use of transformer for high voltages in converter circuit reduces the overall operating efficiency due to leakage inductance and use of transformer also increases the operational cost. . Therefore the proposed system is implemented with transformer less DC-DC converter so as to obtain high DC voltage with the use of nine stage Cockcroft-Walton (CW voltage multiplier. The proposed converter operates in CCM (continuous conduction mode, so that the converter switch stress, the switching losses are reduced. The DC voltage at the input of the proposed model is low and is boosted up by boost inductor (Ls in DC-DC converter stage and performs inverter operation. The number of stages in CW-voltage multiplier circuit is applied with low input pulsating DC (AC Voltage voltage where it is getting converted to high DC output voltage. The proposed converter switches operates at two independent frequencies, modulating (fsm andalternating (fsc frequency. The fsm operates at higher frequency of the output while the fsc operates at lower frequency of the desired output voltage ripple and the output ripples can be adjusted by the switch Sc1 and Sc2. The regulation of the output voltage is achieved by controlling the Duty ratio.The simulation is carried over by the MATLABSIMULINK.

  12. A High-Voltage Level Tolerant Transistor Circuit

    NARCIS (Netherlands)

    Annema, Anne Johan; Geelen, Godefridus Johannes Gertrudis Maria

    2001-01-01

    A high-voltage level tolerant transistor circuit, comprising a plurality of cascoded transistors, including a first transistor (T1) operatively connected to a high-voltage level node (3) and a second transistor (T2) operatively connected to a low-voltage level node (2). The first transistor (T1) con

  13. HIGH VOLTAGE SAFETY MANAGEMENT SYSTEM OF ELECTRIC VEHICLE

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    In order to improve the drivability and energy efficiency of electric vehicle (EV), more and more batteries are connected in series with high voltage which makes it necessary to monitor the electric parameters of high voltage system (HVS) to ensure the high voltage safety. A high voltage safety management system is developed to solve this critical issue. Several key electric parameters including pre-charge, contact resistance, insulation resistance and remaining capacity are monitored and analyzed based on the presented equivalent models. An electronic unit called high voltage safety controller is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated and the on-line electric parameters monitor strategy is discussed. The real vehicle experiment results indicate that the high voltage safety management system designed is suitable for EV application.

  14. Plasma response to transient high voltage pulses

    Indian Academy of Sciences (India)

    S Kar; S Mukherjee

    2013-07-01

    This review reports on plasma response to transient high voltage pulses in a low pressure unmagnetized plasma. Mainly, the experiments are reviewed, when a disc electrode (metallic and dielectric) is biased pulsed negative or positive. The main aim is to review the electron loss in plasmas and particle balance during the negative pulse electrode biasing, when the applied pulse width is less than the ion plasma period. Though the applied pulse width is less than the ion plasma period, ion rarefaction waves are excited. The solitary electron holes are reviewed for positive pulsed bias to the electrode. Also the excitation of waves (solitary electron and ion holes) is reviewed for a metallic electrode covered by a dielectric material. The wave excitation during and after the pulse withdrawal, excitation and propagation characteristics of various electrostatic plasma waves are reviewed here.

  15. RICH High Voltages & PDF Analysis @ LHCb

    CERN Multimedia

    Fanchini, E

    2009-01-01

    In the LHCb experiment an important issue is the identification of the hadrons of the final states of the B mesons decays. Two RICH subdetectors are devoted to this task, and the Hybrid Photon Detectors (HPDs) are the photodetectors used to detect Cherenkov light. In this poster there is a description of how the very high voltage (-18 KV) supply stability used to power the HPDs is monitored. It is also presented the basics of a study which can be done with the first collision data: the analysis of the dimuons from the Drell-Yan process. This process is well known and the acceptance of the LHCb detector in terms of pseudorapidity will be very useful to improve the knowledge of the proton structure functions or, alternatively, try to estimate the luminosity from it.

  16. Simulation Test System of Non-Contact D-dot Voltage Transformer

    Science.gov (United States)

    Yang, Jie; Wang, Jingang; Luo, Ruixi; Gao, Can; Songnong, Li; Kongjun, Zhou

    2016-04-01

    The development trend of future voltage transformer in smart grid is non-contact measurement, miniaturization and intellectualization. This paper proposes one simulation test system of non-contact D-dot transformer for voltage measurement. This simulation test system consists of D-dot transformer, signal processing circuit and ground PC port. D-dot transformer realizes the indirect voltage measurement by measuring the change rate of electric displacement vector, a non-contact means (He et al. 2004, Principles and experiments of voltage transformer based on self-integrating D-dot probe. Proc CSEE 2014;15:2445-51). Specific to the characteristics of D-dot transformer signals, signal processing circuits with strong resistance to interference and distortion-free amplified sensor output signal are designed. WIFI wireless network is used to transmit the voltage detection to LabVIEW-based ground collection port and LabVIEW technology is adopted for signal reception, data processing and analysis and other functions. Finally, a test platform is established to simulate the performance of the whole test system of single-phase voltage transformer. Test results indicate that this voltage transformer has sound real-time performance, high accuracy and fast response speed and the simulation test system is stable and reliable and can be a new prototype of voltage transformers.

  17. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    , and remote power generation for light towers, camper vans, boats, beacons, and buoys etc. In chapter 2, a review of current state-of-the-art is presented. The best performing converters achieve moderately high peak efficiencies at high input voltage and medium power level. However, system dimensioning...

  18. Impact of Solar Array Designs on High Voltage Operations

    Science.gov (United States)

    Brandhorst, Henry W., Jr.; Ferguson, Dale; Piszczor, Mike; ONeill, Mark

    2006-01-01

    As power levels of advanced spacecraft climb above 25 kW, higher solar array operating voltages become attractive. Even in today s satellites, operating spacecraft buses at 100 V and above has led to arcing in GEO communications satellites, so the issue of spacecraft charging and solar array arcing remains a design problem. In addition, micrometeoroid impacts on all of these arrays can also lead to arcing if the spacecraft is at an elevated potential. For example, tests on space station hardware disclosed arcing at 75V on anodized A1 structures that were struck with hypervelocity particles in Low Earth Orbit (LEO) plasmas. Thus an understanding of these effects is necessary to design reliable high voltage solar arrays of the future, especially in light of the Vision for Space Exploration of NASA. In the future, large GEO communication satellites, lunar bases, solar electric propulsion missions, high power communication systems around Mars can lead to power levels well above 100 kW. As noted above, it will be essential to increase operating voltages of the solar arrays well above 80 V to keep the mass of cabling needed to carry the high currents to an acceptable level. Thus, the purpose of this paper is to discuss various solar array approaches, to discuss the results of testing them at high voltages, in the presence of simulated space plasma and under hypervelocity impact. Three different types of arrays will be considered. One will be a planar array using thin film cells, the second will use planar single or multijunction cells and the last will use the Stretched Lens Array (SLA - 8-fold concentration). Each of these has different approaches for protection from the space environment. The thin film cell based arrays have minimal covering due to their inherent radiation tolerance, conventional GaAs and multijunction cells have the traditional cerium-doped microsheet glasses (of appropriate thickness) that are usually attached with Dow Corning DC 93-500 silicone

  19. Energy Storage Options for Voltage Support in Low-Voltage Grids with High Penetration of Photovoltaic

    DEFF Research Database (Denmark)

    Marra, Francesco; Tarek Fawzy, Y.; Bülo, Thorsten

    2012-01-01

    The generation of power by photovoltaic (PV) systems is constantly increasing in low-voltage (LV) distribution grids, in line with the European environmental targets. To cope with the effects on grid voltage profiles during high generation and low demand periods, new solutions need to be establis...

  20. Advances in high voltage power switching with GTOs

    Energy Technology Data Exchange (ETDEWEB)

    Podlesak, T.F. (US Army Electronic Technology and Devices Lab., Fort Monmouth, NJ (US)); McMurray, J.A. (Vitronics, Eatontown, NJ (US)); Carter, J.L.

    1990-12-01

    The control of high voltage at high power, particularly opening switches, has been difficult in the past. Using gate turnoff thyristors (GTOs) arranged in series enables large currents to be switched at high voltage. A high voltage opening switch has been successfully demonstrated in our laboratory. This switch uses GTOs in series and successfully operates at voltages higher than the rated voltage of the individual devices. It is believed that this is the first time this has been successfully demonstrated, in that GTOs have been operated in series before, but always in a manner as to not exceed the voltage capability of the individual devices. In short, the devices have not worked together, sharing the voltage, but one device has been operated using several backup devices. Of particular interest is how well the individual devices share the voltage applied to them. Equal voltage sharing between devices is absolutely essential, in order to not exceed the voltage rating of any of the devices in the series chain. This is accomplished at high (microsecond) switching speeds. Thus, the system is useful for high frequency applications as well as high power, making for a flexible circuit system element. This paper reports on this demonstration system that is rated at 5 KV and uses 1 KV devices. A larger 24 KV system is under design and will use 4.5 KV devices. In order to design the 24 KV switch, the safe operating area of the large devices must be known thoroughly.

  1. LED-Based High-Voltage Lines Warning System

    Directory of Open Access Journals (Sweden)

    Eldar MUSA

    2013-04-01

    Full Text Available LED-based system, running with the current of high-voltage lines and converting the current flowing through the line into the light by using a toroid transformer, has been developed. The transformer’s primary winding is constituted by the high voltage power line. Toroidal core consists of two equal parts and the secondary windings are evenly placed on these two parts. The system is mounted on the high-voltage lines as a clamp. The secondary winding ends are connected in series by the connector on the clamp. LEDs are supplied by the voltage at the ends of secondary. Current flowing through highvoltage transmission lines is converted to voltage by the toroidal transformer and the light emitting LEDs are supplied with this voltage. The theory of the conversion of the current flowing through the line into the light is given. The system, running with the current of the line and converting the current into the light, has been developed. System has many application areas such as warning high voltage lines (warning winches to not hinder the high-voltage lines when working under the lines, warning planes to not touch the high-voltage lines, remote measurement of high-voltage line currents, and local illumination of the line area

  2. Pickup impact on high-voltage multifinger LDMOS-SCR with low trigger voltage and high failure current

    Science.gov (United States)

    Yang, Liu; Jin, Xiangliang; Wang, Yang; Zhou, Acheng

    2015-12-01

    The impact of inserting P+ pickup on high-voltage multi-finger laterally diffused metal-oxide-semiconductor-silicon-controlled rectifier (LDMOS-SCR) has been studied in this article. Four-finger LDMOS-SCR structures with finger length of 50 μm using 0.5 μm 18 V complementarily diffused metal oxide semiconductor (CDMOS) process were fabricated and tested. Theoretical analysis is carried out to make detailed comparisons between LDMOS-SCR with and without P+ pickup. It verifies that the multi-finger LDMOS-SCR with P+ pickup has greater electrostatic discharge (ESD) robustness and effectiveness. Furthermore, transmission line pulse (TLP) test has been done and the results show that the trigger voltage (Vt1) of the LDMOS-SCR with P+ pickup remarkably decreases from 46.19 to 35.39 V and the second breakdown current (It2) effectively increases from 8.13 to 10.08 A.

  3. High Voltage Applications of Explosively Formed Fuses

    Science.gov (United States)

    Tasker, D. G.; Goforth, J. H.; Fowler, C. M.; Herrera, D. H.; King, J. C.; Lopez, E. A.; Martinez, E. C.; Oona, H.; Marsh, S. P.; Reinovsky, R. E.; Stokes, J.; Tabaka, L. J.; Torres, D. T.; Sena, F. C.; Kiuttu, G.; Degnan, J.

    2004-11-01

    At Los Alamos, we have primarily applied Explosively Formed Fuse (EFF) techniques to high current systems. In these systems, the EFF has interrupted currents from 19-25 MA, thus diverting the current to low inductance loads. The transferred current magnitude is determined by the ratio of storage inductance to load inductance and, with dynamic loads, the current has ranged from 12-20 MA. In a system with 18 MJ stored energy, the switch operates at a power of up to 6 TW. We are now investigating the use of the EFF technique to apply high voltages to high impedance loads in systems that are more compact. In these systems we are exploring circuits with EFF lengths from 43-100 cm, which have storage inductances large enough to apply 300-500 kV across high impedance loads. Experimental results and design considerations are presented. Using cylindrical EFF switches of 10 cm diameter and 43 cm length, currents of approximately 3 MA were interrupted producing ~200 kV. This indicates the switch had an effective resistance of ~100 mΩ where 150-200 mΩ was expected. To understand the lower performance, several parameters were studied including electrical conduction through the explosive products; current density; explosive initiation; insulator type and conductor thickness. The results show a number of interesting features, most notably that the primary mechanism of switch operation is mechanical and not electrical fusing of the conductor. Switches opening on a 1-10 μs time scale with resistances starting at 50 μΩ and increasing to perhaps 1 Ω now seem possible to construct using explosive charges as small as a few pounds.

  4. Hazard classification assessment for the High Voltage Initiator

    Energy Technology Data Exchange (ETDEWEB)

    Cogan, J.D.

    1994-04-19

    An investigation was conducted to determine whether the High Voltage Initiator (Sandia p number 395710; Navy NAVSEA No. 6237177) could be assigned a Department of Transportation (DOT) hazard classification of ``IGNITERS, 1.4G, UN0325`` under Code of Federal Regulations, 49 CFR 173.101, when packaged per Mound drawing NXB911442. A hazard classification test was performed, and the test data led to a recommended hazard classification of ``IGNITERS, 1.4G, UN0325,`` based on guidance outlined in DOE Order 1540.2 and 49 CFR 173.56.

  5. Computer Controlled High Precise,High Voltage Pules Generator

    Institute of Scientific and Technical Information of China (English)

    但果; 邹积岩; 丛吉远; 董恩源

    2003-01-01

    High precise, high voltage pulse generator made up of high-power IGBT and pulse transformers controlled by a computer are described. A simple main circuit topology employed in this pulse generator can reduce the cost meanwhile it still meets special requirements for pulsed electric fields (PEFs) in food process. The pulse generator utilizes a complex programmable logic device (CPLD) to generate trigger signals. Pulse-frequency, pulse-width and pulse-number are controlled via RS232 bus by a computer. The high voltage pulse generator well suits to the application for fluid food non-thermal effect in pulsed electric fields, for it can increase and decrease by the step length 1.

  6. Voltage stress effects on microcircuit accelerated life test failure rates

    Science.gov (United States)

    Johnson, G. M.

    1976-01-01

    The applicability of Arrhenius and Eyring reaction rate models for describing microcircuit aging characteristics as a function of junction temperature and applied voltage was evaluated. The results of a matrix of accelerated life tests with a single metal oxide semiconductor microcircuit operated at six different combinations of temperature and voltage were used to evaluate the models. A total of 450 devices from two different lots were tested at ambient temperatures between 200 C and 250 C and applied voltages between 5 Vdc and 15 Vdc. A statistical analysis of the surface related failure data resulted in bimodal failure distributions comprising two lognormal distributions; a 'freak' distribution observed early in time, and a 'main' distribution observed later in time. The Arrhenius model was shown to provide a good description of device aging as a function of temperature at a fixed voltage. The Eyring model also appeared to provide a reasonable description of main distribution device aging as a function of temperature and voltage. Circuit diagrams are shown.

  7. High voltage magnetic pulse generation using capacitor discharge technique

    Directory of Open Access Journals (Sweden)

    M. Rezal

    2014-12-01

    Full Text Available A high voltage magnetic pulse is designed by applying an electrical pulse to the coil. Capacitor banks are developed to generate the pulse current. Switching circuit consisting of Double Pole Double Throw (DPDT switches, thyristor, and triggering circuit is developed and tested. The coil current is measured using a Hall-effect current sensor. The magnetic pulse generated is measured and tabulated in a graph. Simulation using Finite Element Method Magnetics (FEMM is done to compare the results obtained between experiment and simulation. Results show that increasing the capacitance of the capacitor bank will increase the output voltage. This technology can be applied to areas such as medical equipment, measurement instrument, and military equipment.

  8. Health problems from radiation of high-voltage facilities

    Directory of Open Access Journals (Sweden)

    Hossein Ali Yousefi Rizi

    2013-01-01

    Full Text Available Aims: The aim of this study was to survey the health problems caused by exposure to high-voltage facility radiation. Materials and Methods: Sampling included workers exposed to electromagnetic fields at high-voltage facilities. The strength of the electric and magnetic fields was determined by a field meter. A questionnaire was used to evaluate the prevalence of subjective and psychological symptoms. Statistical descriptive used and data analyzed by a Student′s t-tests. Results: This study indicates that increased symptoms among the exposed workers including depression, anxiety, hostility, paranoia, inter-sensitivity, and obsession-compulsion. Some of the self-reported symptoms were, headache (53.5%, fatigue (35.6%, difficulties in concentration (32.5%, vertigo/dizziness (30.4%, attention disorders (28.8%, nervousness (28.1%, and palpitations (14.7%. A significant relationship was observed between the exposure to the electromagnetic field and psychological symptoms (P < 0.05. Conclusion: Radiation of high-voltage facilities probably increased the risk of mental disorders and intensified them in susceptible workers, especially depression. This finding confirmed the results obtained in provocative studies that indicated an increase in the risk of psychological symptoms, which was put forth by several investigators Observation of occupational health and other control measures play an important role in decreasing the symptoms.

  9. An Optoelectronic High-voltage Probe for Measuring Impulse Voltage Distribution of HVDC Converter Valve

    Institute of Scientific and Technical Information of China (English)

    方志; 邱毓昌

    2007-01-01

    A high-voltage optoelectronic probe is developed for measuring impulse voltage distribution along thyristor units in the HVDC converter valve. The dimension of the resistive voltage divider is optimized by means of numerical compttation of electric field. A pulse frequency modulation (PFM) mode is adopted for the data transmission link because of its immunity to high-intensity electromagnetic interference. Experimental results indicate that the linearity deviation for the whole measuring system is within ± 0.15 %, and therefore it can meet requirements specified by IEC60700-1.

  10. High voltage switches having one or more floating conductor layers

    Energy Technology Data Exchange (ETDEWEB)

    Werne, Roger W.; Sampayan, Stephen; Harris, John Richardson

    2015-11-24

    This patent document discloses high voltage switches that include one or more electrically floating conductor layers that are isolated from one another in the dielectric medium between the top and bottom switch electrodes. The presence of the one or more electrically floating conductor layers between the top and bottom switch electrodes allow the dielectric medium between the top and bottom switch electrodes to exhibit a higher breakdown voltage than the breakdown voltage when the one or more electrically floating conductor layers are not present between the top and bottom switch electrodes. This increased breakdown voltage in the presence of one or more electrically floating conductor layers in a dielectric medium enables the switch to supply a higher voltage for various high voltage circuits and electric systems.

  11. Study of High Voltage AC Underground Cable Systems

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Bak, Claus Leth; Wiechowski, Wojciech T.

    2010-01-01

    High-Voltage cables are starting to be more often used to transmit electric energy at high-voltage levels, introducing in the electric grid phenomena that are uncommon when using Overhead Lines. Under the phenomena worthy of special attention are those related with the cable energisation and deen...

  12. A Study on Measurement Error during Alternating Current Induced Voltage Tests on Large Transformers

    Institute of Scientific and Technical Information of China (English)

    WANG Xuan; LI Yun-ge; CAO Xiao-long; LIU Ying

    2006-01-01

    The large transformer is pivotal equipment in an electric power supply system; Its partial discharge test and the induced voltage withstand test on large transformers are carried out at a frequency about twice the working frequency. If the magnetizing inductance cannot compensate for the stray capacitance, the test sample turns into a capacitive load and a capacitive rise exhibits in the testing circuit. For self-restoring insulation, a method has been recommended in IEC60-1 that an unapproved measuring system be calibrated by an approved system at a voltage not less than 50% of the rated testing voltage, and the result then be extrapolated linearly. It has been found that this method leads to great error due to the capacitive rise if it is not correctly used during a withstand voltage test under certain testing conditions, especially for a test on high voltage transformers with large capacity. Since the withstand voltage test is the most important means to examine the operation reliability of a transformer, and it can be destructive to the insulation, a precise measurement must be guaranteed. In this paper a factor, named as the capacitive rise factor, is introduced to assess the rise. The voltage measurement error during the calibration is determined by the parameters of the test sample and the testing facilities, as well as the measuring point. Based on theoretical analysis in this paper, a novel method is suggested and demonstrated to estimate the error by using the capacitive rise factor and other known parameters of the testing circuit.

  13. Multiple High Voltage Pulse Stressing of Polymer Thick Film Resistors

    Directory of Open Access Journals (Sweden)

    Busi Rambabu

    2014-01-01

    Full Text Available The purpose of this paper is to study high voltage interactions in polymer thick film resistors, namely, polyvinyl chloride- (PVC- graphite thick film resistors, and their applications in universal trimming of these resistors. High voltages in the form of impulses for various pulse durations and with different amplitudes have been applied to polymer thick film resistors and we observed the variation of resistance of these resistors with high voltages. It has been found that the resistance of polymer thick film resistors decreases in the case of higher resistivity materials and the resistance of polymer thick film resistor increases in the case of lower resistivity materials when high voltage impulses are applied to them. It has been also found that multiple high voltage pulse (MHVP stressing can be used to trim the polymer thick film resistors either upwards or downwards.

  14. CFD Simulation of Transonic Flow in High-Voltage Circuit Breaker

    Directory of Open Access Journals (Sweden)

    Xiangyang Ye

    2012-01-01

    Full Text Available A high-voltage circuit breaker is an indispensable piece of equipment in the electric transmission and distribution systems. Transonic flow typically occurs inside breaking chamber during the current interruption, which determines the insulating characteristics of gas. Therefore, accurate compressible flow simulations are required to improve the prediction of the breakdown voltages in various test duties of high-voltage circuit breakers. In this work, investigation of the impact of the solvers on the prediction capability of the breakdown voltages in capacitive switching is presented. For this purpose, a number of compressible nozzle flow validation cases have been presented. The investigation is then further extended for a real high-voltage circuit breaker geometry. The correlation between the flow prediction accuracy and the breakdown voltage prediction capability is identified.

  15. Voltage Balancing Method on Expert System for 51-Level MMC in High Voltage Direct Current Transmission

    Directory of Open Access Journals (Sweden)

    Yong Chen

    2016-01-01

    Full Text Available The Modular Multilevel Converters (MMC have been a spotlight for the high voltage and high power transmission systems. In the VSC-HVDC (High Voltage Direct Current based on Voltage Source Converter transmission system, the energy of DC link is stored in the distributed capacitors, and the difference of capacitors in parameters and charge rates causes capacitor voltage balance which affects the safety and stability of HVDC system. A method of MMC based on the expert system for reducing the frequency of the submodules (SMs of the IGBT switching frequency is proposed. Firstly, MMC with 51 levels for HVDC is designed. Secondly, the nearest level control (NLC for 51-level MMC is introduced. Thirdly, a modified capacitor voltage balancing method based on expert system for MMC-based HVDC transmission system is proposed. Finally, a simulation platform for 51-level Modular Multilevel Converter is constructed by using MATLAB/SIMULINK. The results indicate that the strategy proposed reduces the switching frequency on the premise of keeping submodule voltage basically identical, which greatly reduces the power losses for MMC-HVDC system.

  16. Electrical system architecture having high voltage bus

    Science.gov (United States)

    Hoff, Brian Douglas [East Peoria, IL; Akasam, Sivaprasad [Peoria, IL

    2011-03-22

    An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

  17. Living and Working Safely Around High-Voltage Power Lines.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    2001-06-01

    High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

  18. Planar LTCC transformers for high voltage flyback converters.

    Energy Technology Data Exchange (ETDEWEB)

    Schofield, Daryl (NASCENT Technology Inc. , Watertown, SD); Schare, Joshua M.; Glass, Sarah Jill; Roesler, Alexander William; Ewsuk, Kevin Gregory; Slama, George (NASCENT Technology Inc. , Watertown, SD); Abel, Dave (NASCENT Technology Inc. , Watertown, SD)

    2007-06-01

    This paper discusses the design and use of low-temperature (850 C to 950 C) co-fired ceramic (LTCC) planar magnetic flyback transformers for applications that require conversion of a low voltage to high voltage (> 100V) with significant volumetric constraints. Measured performance and modeling results for multiple designs showed that the LTCC flyback transformer design and construction imposes serious limitations on the achievable coupling and significantly impacts the transformer performance and output voltage. This paper discusses the impact of various design factors that can provide improved performance by increasing transformer coupling and output voltage. The experiments performed on prototype units demonstrated LTCC transformer designs capable of greater than 2 kV output. Finally, the work investigated the effect of the LTCC microstructure on transformer insulation. Although this paper focuses on generating voltages in the kV range, the experimental characterization and discussion presented in this work applies to designs requiring lower voltage.

  19. A 600kV 15mA Cockcroft-Walton high-voltage power supply with high stability and low-ripple voltage

    Energy Technology Data Exchange (ETDEWEB)

    Su Tongling [Department of Modern Physics, Lanzhou University, Lanzhou 730000 (China); Zhang Yimin [Department of Modern Physics, Lanzhou University, Lanzhou 730000 (China)]. E-mail: zhangyim03@st.lzu.edu.cn; Chen Shangwen [Department of Modern Physics, Lanzhou University, Lanzhou 730000 (China); Liu Yantong [Department of Modern Physics, Lanzhou University, Lanzhou 730000 (China); Lv Huiyi [Department of Modern Physics, Lanzhou University, Lanzhou 730000 (China); Liu Jiangtao [Department of Modern Physics, Lanzhou University, Lanzhou 730000 (China)

    2006-05-10

    A Cockcroft-Walton high-voltage power supply with high stability and low-ripple voltage has been developed. This power supply has been operated in a ns pulse neutron generator. The maximum non-load voltage is 600kV while the working voltage and load current are 550kV and 15mA, respectively. The tested results indicate that when the power supply is operated at 300kV, 6.7mA and the input voltage varies +/-10%, the long-term stability of the output voltage is S=(0.300-1.006)x10{sup -3}. The ripple voltage is {delta}U{sub P-P}=6.2V at 300kV, 6.8-8.3mA and the ratio of {delta}U{sub P-P} to the output voltage V{sub H} is {delta}U{sub P-P}/V{sub H}=2.1x10{sup -5}.

  20. THE EFFECT OF LIGHTNING ON HIGH VOLTAGE ELECTRICAL SUBSTATIONS’ LOW VOLTAGE SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. I. Fursanov

    2016-01-01

    Full Text Available The article presents the results of studies of the effects of lightning on low voltage systems of high voltage electrical substations with outdoor switchgears of 110 kV. The topicality of research is associated with a wide spreading of such substations as well as with a high reliability requirements of their work and, also, with their widespread distribution and high probability of lightning strikes to the substation or around it. The highest probable and the most dangerous effects of lightning on low voltage systems of a substation are determined on the basis of critical review and special literature analysis and, also, of systematization of practical information that had been collected during the survey of operating substations. Adequate physical models were developed for the list of hazardous effects based on physical processes of lightning. A model of each effect was studied on the basis of the sensitivity theory. The accuracy and adequacy of the models were verified by means of comparison of calculation results for the models under investigation with the results of calculations fulfilled in accordance with specialized programs, as well as from practical or theoretical data obtained by other authors. The factors that had been included in the models were studied and were defined in accordance with their nature (natural or artificial, the range of possible values in a substation was determined; the coefficients of elasticity were calculated. The obtained results enable to ascertain the contribution of the factor in the effect of lightning and the ability to control the factor. The relationship between the factors and the effects of lightning are shown as graphs. For practical application the information, obtained as the result of the research, was organized in the form of checklists that can be applied when collecting baseline information to develop the lightning protection of the substation, to examine the existing lightning protection, to

  1. Switchgear installations for extremely high voltages

    Energy Technology Data Exchange (ETDEWEB)

    Muller, M.; Stepinski, B.

    1964-01-01

    The methods by which 750-kV installations can be economically constructed are described. Besides the choice of phase distances and conductors, the possible layouts and circuitry are dealt with and illustrated by results obtained from the basic studies of 750-kV equipment. In conclusion, a comparison of costs is made, both for the individual components and for the overall financial outlay for the arrangements considered; the total and itemized costs of compounds for voltages of 245 to 750 kV according to the present state of the art are also discussed.

  2. High-voltage air-core pulse transformers

    Energy Technology Data Exchange (ETDEWEB)

    Rohwein, G. J.

    1981-01-01

    General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

  3. High voltage high repetition rate pulse using Marx topology

    Science.gov (United States)

    Hakki, A.; Kashapov, N.

    2015-06-01

    The paper describes Marx topology using MOSFET transistors. Marx circuit with 10 stages has been done, to obtain pulses about 5.5KV amplitude, and the width of the pulses was about 30μsec with a high repetition rate (PPS > 100), Vdc = 535VDC is the input voltage for supplying the Marx circuit. Two Ferrite ring core transformers were used to control the MOSFET transistors of the Marx circuit (the first transformer to control the charging MOSFET transistors, the second transformer to control the discharging MOSFET transistors).

  4. High voltage, low inductance hydrogen thyratron study program

    Science.gov (United States)

    Caristi, R. F.; Turnquist, D.

    1981-01-01

    The second phase of a multi-phase program of research and development to gain the information necessary to fabricate a high voltage, low inductance hydrogen thyratron switch has now been completed. The thyratron is to be capable of switching tens of kiloamperes within tens of nanoseconds at voltage levels as high as 250 kV. To achieve low inductance, the thyratron is operated within a close-fitting coaxial current return. Both the tube and the return are made physically short, and the tube is designed such that the discharge is constrained to flow principally at the outer reaches of the device. A technique has been developed for modelling various types of box grids and then using computer-generated field plots to aid in the specifics of grid design. This model has been used to generate a comprehensive set of theoretical relations that are useful to determine the anode dissipation to be expected. Experimental results are described and discussed. Included are the ceramic test results, holdoff vs. time on charge and gas pressure, stage voltage addition, operation at high pulse repetition rates, current rise time as a function of gas pressure, and the triggering characteristics of multi-stage, box-grid tubes. Finally, the design of an intermediate experimental tube is discussed at length. This tube is expected to have an inductance less than 50 nH and to operate at 150 kV. Its design is based on both the theoretical and experimental results obtained during this phase of the research program. The overall conclusion is that a hydrogen thyratron capable of achieving the program's objectives is a feasible proposition.

  5. Highly-Efficient and Modular Medium-Voltage Converters

    Science.gov (United States)

    2015-09-28

    4. TITLE AND SUBTITLE Highly-Efficient and Modula Medium -Voltage Converters 6. AUTHOR(S) Maryam Saeedifard 7. PERFORMING ORGANIZATIC i NAME(S...realization of highly efficient, modular medium - voltage dc-ac and dc-dc energy conversion systems by development of new control strategies that improve the...Z39.18 a 01^ 100(0^5 Final Report for Grant N00014-14-1-0615 Highly-Efficient and Modular Medium -Voltage Converters Lead Organization: Georgia Tech

  6. System for instrumenting and manipulating apparatuses in high voltage

    Science.gov (United States)

    Jordan, Kevin

    2016-06-07

    A system for energizing, operating and manipulating apparatuses in high voltage systems. The system uses a dielectric gas such as SF.sub.6 as a driving power supply for a pneumatic motor which ultimately charges a battery or other energy storage device. The stored energy can then be used for instrumentation equipment, or to power any electrical equipment, in the high voltage deck. The accompanying method provides for the use of the SF6 system for operating an electrical device in a high-voltage environment.

  7. A Novel Series Connected Batteries State of High Voltage Safety Monitor System for Electric Vehicle Application

    Directory of Open Access Journals (Sweden)

    Qiang Jiaxi

    2013-01-01

    Full Text Available Batteries, as the main or assistant power source of EV (Electric Vehicle, are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS, the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application.

  8. High Voltage Breakdown Levels in Various EPC Potting Materials

    Science.gov (United States)

    Komm, David S.

    2006-01-01

    This viewgraph presentation reviews exploration activities at JPL into various potting materials. Since high power space-borne microwave transmitters invariably use a vacuum tube as a final power amplifier, and this tube requires high electrode voltages for operation. The associated high voltage insulation typically represents a significant fraction of the mass of the transmitter. Since mass is always a premium resource on board spacecraft, we have been investigating materials with the potential to reduce the mass required for our applications here at JPL. This paper describes electrical breakdown results obtained with various potting materials. Conathane EN-11 (polyurethane) is the traditional HVPS encapsulant at JPL, but due to temperature limitations and durability issues it was deemed inappropriate for the particular application (i.e., CloudSat radar). The choices for the best available materials were epoxies, or silicones. Epoxies are too rigid, and were deemed inadvisable. Two silicones were further investigated (i.e.,ASTM E595- 93e2: GE RTV566(R) and Dow Corning 93-500X(R), another compound was considered (i.e., DC material, Sylgard 184(R)). "Loading" (adding filler materials) the potting compound will frequently alter the final material properties. Powdered alumina and borosilicate glass known as "microballoons" were investigated as possible loading materials. The testing of the materials is described. Each of the two loading materials offers advantages and disadvantages. The advantages and disadvantages are described.

  9. A Method of Unbalanced Current Off-line Test for High-voltage Capacitors in Converter Station%换流站高压电容器不平衡电流离线测试方法

    Institute of Scientific and Technical Information of China (English)

    吴鹏; 摆亲; 刘志远; 张振宇

    2014-01-01

    对换流站高压电容器不平衡电流理论计算进行简单推导,并以不同工频电压作用下不平衡电流的线性关系为基本原理,介绍了低工频电压下离线试验测试不平衡电流大小与理论计算值之间的差别,并通过对误差由浅入深地分析,从而得出现场运行维护人员提高不平衡电流测试值准确性的关键方法,即合理优化现场试验接线以减少电磁干扰,并适当对比理论计算值与离线试验测试值的方法,从而确保桥臂不平衡电流离线测试值的准确性。通过电容器调整或更换,满足了离线测试不平衡电流大小要求,能保障设备投入电网后的稳定运行。%This paper describes the unbalanced current theoretical formula of the high-voltage capacitors in a converter station, and with the linear relationship of unbalanced current under the action of different power frequency voltages as the basic principle,the difference between the unbalanced current theoretical value and off-line testing value under low power frequency voltage is accounted for.Through analysis of the cause of the difference from shallow to deep,the conclusion is reached that the key method by which the field maintenance personnel can improve the accuracy of unbalanced current test is through rational and optimized test wiring to reduce electromagnetic interference and appropriately compare theoretical value with off-line test value to ensure the accuracy of the bridge arm unbalanced current off-line test value.Through the capacitor adj ustment or replacement,the off-line test values of the unbalanced current are up to requirement for ensuring stable equipment work in operation.

  10. Role of Stress Voltage on Structural Degradation of GaN High-Electron-Mobility Transistors

    Science.gov (United States)

    2010-01-01

    GaN high-electron-mobility transistors ( HEMTs ) under high- voltage electrical stress degradation in the drain and gate current is electric field... GaN HEMTs after long-term DC and RF life tests at high voltage [12–16]. Crystallographic defects such as pits and cracks have been observed at the...created by high-voltage stress in GaN HEMTs . A complementary study of the evolution of these de- fects in the cross section as a function of stress

  11. Enhanced Model of Nonlinear Spiral High Voltage Divider

    Directory of Open Access Journals (Sweden)

    V. Panko

    2015-04-01

    Full Text Available This paper deals with the enhanced accurate DC and RF model of nonlinear spiral polysilicon voltage divider. The high resistance polysilicon divider is a sensing part of the high voltage start-up MOSFET transistor that can operate up to 700 V. This paper presents the structure of a proposed model, implemented voltage, frequency and temperature dependency, and scalability. A special attention is paid to the ability of the created model to cover the mismatch and influence of a variation of process parameters on the device characteristics. Finally, the comparison of measured data vs. simulation is presented in order to confirm the model validity and a typical application is demonstrated.

  12. Integrated differential high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Farch, Kjartan

    2015-01-01

    In this paper an integrated differential high-voltage transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is designed and implemented in a 0.35 μm high-voltage process. Measurements are performed on the integrated circuit in order...... to assess its performance. The circuit generates pulses at differential voltage levels of 60V, 80V and 100 V, a frequency up to 5MHz and a measured driving strength of 1.75 V/ns with the CMUT connected. The total on-chip area occupied by the transmitting circuit is 0.18 mm2 and the power consumption...

  13. Low-profile high-voltage compact gas switch

    Energy Technology Data Exchange (ETDEWEB)

    Goerz, D.A.; Wilson, M.J.; Speer, R.D.

    1997-06-30

    This paper discusses the development and testing of a low-profile, high-voltage, spark-gap switch designed to be closely coupled with other components into an integrated high-energy pulsed-power source. The switch is designed to operate at 100 kV using SF6 gas pressurized to less than 0.7 MPa. The volume of the switch cavity region is less than 1.5 cm3, and the field stress along the gas-dielectric interface is as high as 130 kV/cm. The dielectric switch body has a low profile that is only I -cm tall at its greatest extent and nominally 2-mm thick over most of its area. This design achieves a very low inductance of less than 5 nH, but results in field stresses exceeding 500 kV/cm in the dielectric material. Field modeling was done to determine the appropriate shape for the highly stressed insulator and electrodes, and special manufacturing techniques were employed to mitigate the usual mechanisms that induce breakdown and failure in solid dielectrics. Static breakdown tests verified that the switch operates satisfactorily at 100 kV levels. The unit has been characterized with different shaped electrodes having nominal gap spacings of 2.0, 2.5, and 3.0 mm. The relationship between self-break voltage and operating pressure agrees well with published data on gas properties, accounting for the field enhancements of the electrode shapes being used. Capacitor discharge tests in a low inductance test fixture exhibited peak currents up to 25 kA with characteristic frequencies of the ringdown circuit ranging from 10 to 20 MHz. The ringdown waveforms and scaling of measured parameters agree well with circuit modeling of the switch and test fixture. Repetitive operation has been demonstrated at moderate rep-rates up to 15 Hz, limited by the power supply being used. Preliminary tests to evaluate lifetime of the compact switch assembly have been encouraging. In one case, after more than 7,000 high-current ringdown tests with approximately 30 C of total charge transferred, the

  14. High Voltage Bi-directional Flyback Converter for Capacitive Actuator

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    This paper presents a high voltage DC-DC converter topology for bi-directional energy transfer between a low voltage DC source and a high voltage capacitive load. The topology is a bi-directional flyback converter with variable switching frequency control during the charge mode, and constant...... switching frequency control during the discharge mode. The converter is capable of charging the capacitive load from 24 V DC source to 2.5 kV, and discharges it to 0 V. The flyback converter has been analyzed in detail during both charge and discharge modes, by considering all the parasitic elements...... in the converter, including the most dominating parameters of the high voltage transformer viz., self-capacitance and leakage inductance. The specific capacitive load for this converter is a dielectric electro active polymer (DEAP) actuator, which can be used as an effective replacement for conventional actuators...

  15. A compact, all solid-state LC high voltage generator.

    Science.gov (United States)

    Fan, Xuliang; Liu, Jinliang

    2013-06-01

    LC generator is widely applied in the field of high voltage generation technology. A compact and all solid-state LC high voltage generator based on saturable pulse transformer is proposed in this paper. First, working principle of the generator is presented. Theoretical analysis and circuit simulation are used to verify the design of the generator. Experimental studies of the proposed LC generator with two-stage main energy storage capacitors are carried out. And the results show that the proposed LC generator operates as expected. When the isolation inductance is 27 μH, the output voltage is 1.9 times larger than the charging voltage on single capacitor. The multiplication of voltages is achieved. On the condition that the primary energy storage capacitor is charged to 857 V, the output voltage of the generator can reach to 59.5 kV. The step-up ratio is nearly 69. When self breakdown gas gap switch is used as main switch, the rise time of the voltage pulse on load resistor is 8.7 ns. It means that the series-wound inductance in the discharging circuit is very small in this system. This generator can be employed in two different applications.

  16. High performance dc-dc conversion with voltage multipliers

    Science.gov (United States)

    Harrigill, W. T.; Myers, I. T.

    1974-01-01

    The voltage multipliers using capacitors and diodes first developed by Cockcroft and Walton in 1932 were reexamined in terms of state of the art fast switching transistors and diodes, and high energy density capacitors. Because of component improvements, the voltage multiplier, used without a transformer, now appears superior in weight to systems now in use for dc-dc conversion. An experimental 100-watt 1000-volt dc-dc converter operating at 100 kHz was built, with a component weight of about 1 kg/kW. Calculated and measured values of output voltage and efficiency agreed within experimental error.

  17. High-frequency high-voltage high-power DC-to-DC converters

    Science.gov (United States)

    Wilson, T. G.; Owen, H. A.; Wilson, P. M.

    1982-01-01

    A simple analysis of the current and voltage waveshapes associated with the power transistor and the power diode in an example current-or-voltage step-up (buck-boost) converter is presented. The purpose of the analysis is to provide an overview of the problems and design trade-offs which must be addressed as high-power high-voltage converters are operated at switching frequencies in the range of 100 kHz and beyond. Although the analysis focuses on the current-or-voltage step-up converter as the vehicle for discussion, the basic principles presented are applicable to other converter topologies as well.

  18. Planar LTCC transformers for high voltage flyback converters: Part II.

    Energy Technology Data Exchange (ETDEWEB)

    Schofield, Daryl (NASCENTechnology, Inc., Watertown, SD); Schare, Joshua M., Ph.D.; Slama, George (NASCENTechnology, Inc., Watertown, SD); Abel, David (NASCENTechnology, Inc., Watertown, SD)

    2009-02-01

    This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

  19. On-chip High-Voltage Generator Design

    CERN Document Server

    Tanzawa, Toru

    2013-01-01

    This book describes high-voltage generator design with switched-capacitor multiplier techniques.  The author provides various design techniques for switched-capacitor on-chip high-voltage generators, including charge pump circuits, regulators, level shifters, references, and oscillators.  Readers will see these techniques applied to system design in order to address the challenge of how the on-chip high-voltage generator is designed for Flash memories, LCD drivers, and other semiconductor devices to optimize the entire circuit area and power efficiency with a low voltage supply, while minimizing the cost.   ·         Shows readers how to design charge pump circuits with lower voltage operation, higher power efficiency, and smaller circuit area; ·         Describes comprehensive circuits and systems design of on-chip high-voltage generators; ·         Covers all the component circuit blocks, including charge pumps, pump regulators, level shifters, oscillators, and references.

  20. A New Phase-Shifted Cascade High Voltage Inverter

    Institute of Scientific and Technical Information of China (English)

    Lau Eng Tin

    2005-01-01

    This paper presents a unique novel design of the phase-shifted cascade high voltage inverter. Thehigh voltage inverter utilizes fewer power switches and supplies a balance load. The usage of phase shifttransformer and phase shifting SPWM ensures that input and output harmonic wave content is low and outputvoltage change (du/dt) has a low rate, meeting all the requirements of the power authorities. The most out-standing feature is the energy saving with very fast cost recovery.

  1. Requirement of ultra-high voltage GIS arrester to voltage gradient of metal-oxide varistor

    Institute of Scientific and Technical Information of China (English)

    HE JinLiang; HU Jun; MENG BoWen; ZHANG Bo; ZHU Bin; CHEN ShuiMing; ZENG Rong

    2009-01-01

    The surge arrestor with excellent protection characteristics would decrease the overvoltage level ap-plied on the power apparatus to reduce their insulation levels and manufacturing bottleneck. The ar-restor for the 1000-kV ultra-high voltage ac power transmission system is designed as tank-type structure. The field-circuit combination numerical method combining the three-dimensional finite ele-ment method with circuit is proposed to analyze the potential distribution of GIS arrester. By comparing several design schemes, the most effective method to improve the potential distribution along the varistor column is to increase the voltage gradient of the ZnO varistor. Synthesizing several influential factors, the suitable voltage gradient of ZnO varistor should be controlled to 435 V/mm, and the re-sulted nonuniform degree of the potential distribution along the varistor column inside the GIS arrestor would be controlled smaller than 10%. The result in this paper provides the fundamental technical in-dex for the study of the high voltage gradient ZnO varistors.

  2. Requirement of ultra-high voltage GIS arrester to voltage gradient of metal-oxide varistor

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The surge arrester with excellent protection characteristics would decrease the overvoltage level ap- plied on the power apparatus to reduce their insulation levels and manufacturing bottleneck. The arrester for the 1000-kV ultra-high voltage ac power transmission system is designed as tank-type structure. The field-circuit combination numerical method combining the three-dimensional finite element method with circuit is proposed to analyze the potential distribution of GIS arrester. By comparing several design schemes, the most effective method to improve the potential distribution along the varistor column is to increase the voltage gradient of the ZnO varistor. Synthesizing several influential factors, the suitable voltage gradient of ZnO varistor should be controlled to 435 V/mm, and the resulted nonuniform degree of the potential distribution along the varistor column inside the GIS arrester would be controlled smaller than 10%. The result in this paper provides the fundamental technical index for the study of the high voltage gradient ZnO varistors.

  3. 30 CFR 77.807-1 - High-voltage powerlines; clearances above ground.

    Science.gov (United States)

    2010-07-01

    ... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-1 High-voltage powerlines; clearances above ground. High-voltage powerlines located above driveways, haulageways, and railroad tracks...

  4. Temperature Stabilized Characterization of High Voltage Power Supplies

    CERN Document Server

    Krarup, Ole

    2017-01-01

    High precision measurements of the masses of nuclear ions in the ISOLTRAP experiment relies on an MR-ToF. A major source of noise and drift is the instability of the high voltage power supplies employed. Electrical noise and temperature changes can broaden peaks in time-of-flight spectra and shift the position of peaks between runs. In this report we investigate how the noise and drift of high-voltage power supplies can be characterized. Results indicate that analog power supplies generally have better relative stability than digitally controlled ones, and that the high temperature coefficients of all power supplies merit efforts to stabilize them.

  5. High voltage switch triggered by a laser-photocathode subsystem

    Science.gov (United States)

    Chen, Ping; Lundquist, Martin L.; Yu, David U. L.

    2013-01-08

    A spark gap switch for controlling the output of a high voltage pulse from a high voltage source, for example, a capacitor bank or a pulse forming network, to an external load such as a high gradient electron gun, laser, pulsed power accelerator or wide band radar. The combination of a UV laser and a high vacuum quartz cell, in which a photocathode and an anode are installed, is utilized as triggering devices to switch the spark gap from a non-conducting state to a conducting state with low delay and low jitter.

  6. Voltage source inverters for high power, variable-voltage DC power sources

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z. [Department of Engineering and Technology, De Montfort University, Queens Building, The Gateway, Leicester, LE1 9BH, (United Kingdom); Spooner, E. [School of Engineering, University of Durham, Science Laboratories, South Rd, Durham, DRI 3LE, (United Kingdom)

    2001-09-01

    The paper discusses the applications of voltage source inverter (VSI) based power electronic systems for interfacing variable-voltage DC sources to the grid. A variable-speed wind power conversion system is used for illustration, where the VSI-based interface needs to convert a variable DC voltage to a nearly constant AC voltage with high-quality power. The power control principles of VSI are described. Various system configurations and switching strategies are examined by analysis, simulation and experimental methods. It is shown that better utilisation of semiconductors and more flexible control may be achieved by using a separately controlled DC link, rather than a directly connected VSI that has to operate at a lower modulation ratio at higher power. In some cases, multipulse inverter structures may be preferred, despite higher component count, because of reduced switching losses, fault tolerance and the absence of filters. The solutions developed in the study could be applied at a different scale to other renewable energy sources, such as wave or solar photovoltaic devices. (Author)

  7. Experimental investigation of SDBD plasma actuator driven by AC high voltage with a superimposed positive pulse bias voltage

    Science.gov (United States)

    Qi, Xiao-Hua; Yan, Hui-Jie; Yang, Liang; Hua, Yue; Ren, Chun-Sheng

    2017-08-01

    In this work, a driven voltage consisting of AC high voltage with a superimposed positive pulse bias voltage ("AC+ Positive pulse bias" voltage) is adopted to study the performance of a surface dielectric barrier discharge plasma actuator under atmospheric conditions. To compare the performance of the actuator driven by single-AC voltage and "AC+ Positive pulse bias" voltage, the actuator-induced thrust force and power consumption are measured as a function of the applied AC voltage, and the measured results indicate that the thrust force can be promoted significantly after superimposing the positive pulse bias voltage. The physical mechanism behind the thrust force changes is analyzed by measuring the optical properties, electrical characteristics, and surface potential distribution. Experimental results indicate that the glow-like discharge in the AC voltage half-cycle, next to the cycle where a bias voltage pulse has been applied, is enhanced after applying the positive pulse bias voltage, and this perhaps is the main reason for the thrust force increase. Moreover, surface potential measurement results reveal that the spatial electric field formed by the surface charge accumulation after positive pulse discharge can significantly affect the applied external electric field, and this perhaps can be responsible for the experimental phenomenon that the decrease of thrust force is delayed by pulse bias voltage action after the filament discharge occurs in the glow-like discharge region. The schlieren images further verify that the actuator-induced airflow velocity increases with the positive pulse voltage.

  8. Artifical Excitation of Ferro-Resonance for Testing Electrotechnical Equipment in Distribution Devices with Increased Voltage

    Directory of Open Access Journals (Sweden)

    Ye. V. Dmitriev

    2006-01-01

    Full Text Available On the basis of the developed device for protection against of ferro-resonant and high-frequency cumulative over-voltages an algorithm for obtaining a voltage imitating ferro-resonant over-voltages is proposed in the paper. This algorithm presupposes to apply a voltage to the secondary transformer side from an extraneous source is proposed.

  9. High-Capacity, High-Voltage Composite Oxide Cathode Materials

    Science.gov (United States)

    Hagh, Nader M.

    2015-01-01

    This SBIR project integrates theoretical and experimental work to enable a new generation of high-capacity, high-voltage cathode materials that will lead to high-performance, robust energy storage systems. At low operating temperatures, commercially available electrode materials for lithium-ion (Li-ion) batteries do not meet energy and power requirements for NASA's planned exploration activities. NEI Corporation, in partnership with the University of California, San Diego, has developed layered composite cathode materials that increase power and energy densities at temperatures as low as 0 degC and considerably reduce the overall volume and weight of battery packs. In Phase I of the project, through innovations in the structure and morphology of composite electrode particles, the partners successfully demonstrated an energy density exceeding 1,000 Wh/kg at 4 V at room temperature. In Phase II, the team enhanced the kinetics of Li-ion transport and electronic conductivity at 0 degC. An important feature of the composite cathode is that it has at least two components that are structurally integrated. The layered material is electrochemically inactive; however, upon structural integration with a spinel material, the layered material can be electrochemically activated and deliver a large amount of energy with stable cycling.

  10. Dielectric insulation and high-voltage issues

    CERN Document Server

    Tommasini, D

    2010-01-01

    Electrical faults are in most cases dramatic events for magnets, due to the large stored energy which is potentially available to be dissipated at the fault location. After a reminder of the principles of electrostatics in Section 1, the basic mechanisms of conduction and breakdown in dielectrics are summarized in Section 2. Section 3 introduces the types and function of the electrical insulation in magnets, and Section 4 its relevant failure mechanisms. Section 5 deals with ageing and, finally, Section 6 gives some principles for testing. Though the School specifically dealt with warm magnets, for completeness some principles of dielectric insulation for superconducting accelerator magnets are briefly summarized in a dedicated appendix.

  11. A consistent approach to estimate the breakdown voltage of high voltage electrodes under positive switching impulses

    Science.gov (United States)

    Arevalo, L.; Wu, D.; Jacobson, B.

    2013-08-01

    The main propose of this paper is to present a physical model of long air gap electrical discharges under positive switching impulses. The development and progression of discharges in long air gaps are attributable to two intertwined physical phenomena, namely, the leader channel and the streamer zone. Experimental studies have been used to develop empirical and physical models capable to represent the streamer zone and the leader channel. The empirical ones have led to improvements in the electrical design of high voltage apparatus and insulation distances, but they cannot take into account factors associated with fundamental physics and/or the behavior of materials. The physical models have been used to describe and understand the discharge phenomena of laboratory and lightning discharges. However, because of the complex simulations necessary to reproduce real cases, they are not in widespread use in the engineering of practical applications. Hence, the aim of the work presented here is to develop a model based on physics of the discharge capable to validate and complement the existing engineering models. The model presented here proposes a new geometrical approximation for the representation of the streamer and the calculation of the accumulated electrical charge. The model considers a variable streamer region that changes with the temporal and spatial variations of the electric field. The leader channel is modeled using the non local thermo-equilibrium equations. Furthermore, statistical delays before the inception of the first corona, and random distributions to represent the tortuous nature of the path taken by the leader channel were included based on the behavior observed in experimental tests, with the intention of ensuring the discharge behaved in a realistic manner. For comparison purposes, two different gap configurations were simulated. A reasonable agreement was found between the physical model and the experimental test results.

  12. An optical remote controlled high voltage dome for electron microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Ruan, S. [The Enrico Fermi Institute, The University of Chicago, Chicago, Illinois 60637 (United States); Kapp, O.H. [The Department of Radiology and the Enrico Fermi Institute, The University of Chicago, Chicago, Illinois 60637 (United States)

    1995-08-01

    A low cost high voltage dome has been completed for an electron microscope with a thermal emission tip as electron source. Two fibers are used to provide communication across the high electrical field zone between the computer and the dome. This system provides a reliable method to operate the dome circuitry (floating at high voltage) and ensures the safety of both the computer system and the operator. Because of the application of ``dummy`` serial data transfer, the least number of fibers and associated components are used, providing a relatively low-cost solution to this problem. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  13. A design of High-precision High-Voltage Fiber-Optic Analog Signal Isolation Converter

    Institute of Scientific and Technical Information of China (English)

    李建伟; 许留伟; 刘小宁; 杨雷

    2002-01-01

    This paper introduces a design of high-prectison high-voltage fiber-optic analog sig-nal isoaltion converter based on the technology of Voltage-to-Fequency (V/F)and Frequency -to Voltage(F/V) conversion It describes the principle ,system configuration and hardware design

  14. High-voltage pulsed generator for dynamic fragmentation of rocks.

    Science.gov (United States)

    Kovalchuk, B M; Kharlov, A V; Vizir, V A; Kumpyak, V V; Zorin, V B; Kiselev, V N

    2010-10-01

    A portable high-voltage (HV) pulsed generator has been designed for rock fragmentation experiments. The generator can be used also for other technological applications. The installation consists of low voltage block, HV block, coaxial transmission line, fragmentation chamber, and control system block. Low voltage block of the generator, consisting of a primary capacitor bank (300 μF) and a thyristor switch, stores pulse energy and transfers it to the HV block. The primary capacitor bank stores energy of 600 J at the maximum charging voltage of 2 kV. HV block includes HV pulsed step up transformer, HV capacitive storage, and two electrode gas switch. The following technical parameters of the generator were achieved: output voltage up to 300 kV, voltage rise time of ∼50 ns, current amplitude of ∼6 kA with the 40 Ω active load, and ∼20 kA in a rock fragmentation regime (with discharge in a rock-water mixture). Typical operation regime is a burst of 1000 pulses with a frequency of 10 Hz. The operation process can be controlled within a wide range of parameters. The entire installation (generator, transmission line, treatment chamber, and measuring probes) is designed like a continuous Faraday's cage (complete shielding) to exclude external electromagnetic perturbations.

  15. The dynamic response of a hot-wire anemometer: IV. Sine-wave voltage perturbation testing for near-wall hot-wire/film probes and the presence of low-high frequency response characteristics

    Science.gov (United States)

    Teo, C. J.; Khoo, B. C.; Teo, C. J.; Chew, Y. T.

    2001-01-01

    Experiments were performed using the electronic sine-wave voltage-perturbation test to systematically study the frequency responses of near-wall hot-wire probes subjected in turn to varying magnitudes of convective velocity and different effects of wall influence. In addition, quartz-substrate hot-film gauges with various thicknesses of quartz coating were also investigated. Results of the high cut-off frequency obtained using the sine-wave test (fsine) were found to be in fair agreement with those obtained using the square-wave test (fS) both for hot-wire and for hot-film sensors. The sine-wave test response curve exhibited a distinct bulging effect for the hot-film gauges. For the hot-wire sensors, a much weaker bulging effect was also observed. In contrast to fS and fsine, the low frequency response characteristic corresponding to the location of the bulging effect (fbulge) compared much more favourably with the dynamic frequency response (fD) obtained by Khoo et al and Chew et al using a known near-wall fluctuating flow field. Freymuth's theory for non-cylindrical hot-film sensors incorporating the Bellhouse-Schultz model was applied to predict the responses of the hot-film wall gauges when they were subjected to electronic sine-wave testing and dynamic perturbation testing under different parametric conditions. Although it is one-dimensional in nature, the model is capable of predicting most of the trends observed in the present study and previous works by Khoo et al (1998a) and Chew et al (1998a).

  16. OFDM-based Low-voltage Powerline High Rate Communication

    Institute of Scientific and Technical Information of China (English)

    ZHANG You-bing(张有兵); CHENG Shi-jie(程时杰); Joseph Nguimbis; XIONG Lan(熊兰)

    2004-01-01

    Based on the experimental results, a simplified model for low-voltage powerline used as a high frequency communication channel is presented. With this model, the Orthogonal Frequency Division Multiplexing (OFDM) based high rate digital communication over low-voltage powerline is analyzed and simulated. The capability of thc signal transmission system in overcoming multi-path interference and selection of the system parameters are discussed. And time-domain simulation is carried out to investigate the transmission capability of the OFDM cammunication system for different mapping schemes and transmission power levels. Simulation results show that it is possible to realize high rate digital communication over iow-voltage powerliue using OFDM when the transmitted power is large enough.

  17. Integrated reconfigurable high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Jørgensen, Ivan Harald Holger

    2015-01-01

    In this paper a high-voltage transmitting circuit aimed for capacitive micromachined ultrasonic transducers (CMUTs) used in scanners for medical applications is designed and implemented in a 0.35 μm high-voltage CMOS process. The transmitting circuit is reconfigurable externally making it able...... performance. The design occupies an on-chip area of 0.938 mm2 and the power consumption of a 128-element transmitting circuit array that would be used in an portable ultrasound scanner is found to be a maximum of 181 mW....

  18. Integrated reconfigurable high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Jørgensen, Ivan Harald Holger;

    2015-01-01

    In this paper a high-voltage transmitting circuit aimed for capacitive micromachined ultrasonic transducers (CMUTs) used in scanners for medical applications is designed and implemented in a 0.35 μm high-voltage CMOS process. The transmitting circuit is reconfigurable externally making it able...... performance. The design occupies an on-chip area of 0.938 mm2 and the power consumption of a 128-element transmitting circuit array that would be used in an portable ultrasound scanner is found to be a maximum of 181 mW....

  19. High-voltage breakdown studies on Si microstrip detectors

    CERN Document Server

    Albergo, S; Azzi, P; Babucci, E; Bacchetta, N; Bader, A J; Bagliesi, G; Basti, A; Biggeri, U; Bilei, G M; Bisello, D; Boemi, D; Bosi, F; Borrello, L; Bozzi, C; Braibant, S; Breuker, Horst; Bruzzi, Mara; Buffini, A; Busoni, S; Calefato, G; Candelori, A; Caner, A; Castaldi, R; Castro, A; Catacchini, E; Checcucci, B; Ciampolini, P; Civinini, C; Creanza, D; D'Alessandro, R; Da Rold, M; Demaria, N; De Palma, M; Dell'Orso, R; Marina, R D; Dutta, S; Eklund, C; Peisert, Anna; Feld, L; Fiore, L; Focardi, E; French, M; Freudenreich, Klaus; Fürtjes, A; Giassi, A; Giorgi, M A; Giraldo, A; Glessing, B; Gu, W H; Hall, G; Hammarström, R; Hebbeker, T; Hrubec, Josef; Muhtinen, M; Kaminski, A; Karimäki, V; Saint-Koenig, M; Krammer, Manfred; Lariccia, P; Lenzi, M; Loreti, M; Lübelsmeyer, K; Lustermann, W; Mättig, P; Maggi, G; Mannelli, M; Mantovani, G C; Marchioro, A; Mariotti, C; Martignon, G; McEvoy, B; Meschini, M; Messineo, A; My, S; Paccagnella, A; Palla, Fabrizio; Pandoulas, D; Papi, A; Parrini, G; Passeri, D; Pieri, M; Piperov, S; Potenza, R; Radicci, V; Raffaelli, F; Raymond, M; Santocchia, A; Schmitt, B; Selvaggi, G; Servoli, L; Sguazzoni, G; Siedling, R; Silvestris, L; Skog, K; Starodumov, Andrei; Stavitski, I; Stefanini, G; Tempesta, P; Tonelli, G; Tricomi, A; Tuuva, T; Vannini, C; Verdini, P G; Viertel, Gert M; Zie, Z; Li Ya Hong; Watts, S; Wittmer, B

    1999-01-01

    The breakdown performance of CMS barrel module prototype detectors and test devices with single and multi-guard structures were studied before and after neutron irradiation up to 2-10/sup 14/ 1 MeV equivalent neutrons. Before irradiation avalanche breakdown occurred at the guard ring implant edges. We measured 100-300 V higher breakdown voltage values for the devices with multi-guard than for devices with single-guard ring, After irradiation and type inversion the breakdown was smoother than before irradiation and the breakdown voltage value increased to 500-600 V for most of the devices. (9 refs).

  20. High-voltage, high-current, solid-state closing switch

    Energy Technology Data Exchange (ETDEWEB)

    Focia, Ronald Jeffrey

    2017-08-22

    A high-voltage, high-current, solid-state closing switch uses a field-effect transistor (e.g., a MOSFET) to trigger a high-voltage stack of thyristors. The switch can have a high hold-off voltage, high current carrying capacity, and high time-rate-of-change of current, di/dt. The fast closing switch can be used in pulsed power applications.

  1. Digitally Programmable High-Q Voltage Mode Universal Filter

    Directory of Open Access Journals (Sweden)

    D. Singh

    2013-12-01

    Full Text Available A new low-voltage low-power CMOS current feedback amplifier (CFA is presented in this paper. This is used to realize a novel digitally programmable CFA (DPCFA using transistor arrays and MOS switches. The proposed realizations nearly allow rail-to-rail swing capability at all the ports. Class-AB output stage ensures low power dissipation and high current drive capability. The proposed CFA/ DPCFA operates at supply voltage of ±0.75 V and exhibits bandwidth better than 95 MHz. An application of the DPCFA to realize a novel voltage mode high-Q digitally programmable universal filter (UF is given. Performances of all the proposed circuits are verified by PSPICE simulation using TSMC 0.25μm technology parameters.

  2. Cardiac stimulation with high voltage discharge from stun guns.

    Science.gov (United States)

    Nanthakumar, Kumaraswamy; Massé, Stephane; Umapathy, Karthikeyan; Dorian, Paul; Sevaptsidis, Elias; Waxman, Menashe

    2008-05-20

    The ability of an electrical discharge to stimulate the heart depends on the duration of the pulse, the voltage and the current density that reaches the heart. Stun guns deliver very short electrical pulses with minimal amount of current at high voltages. We discuss external stimulation of the heart by high voltage discharges and review studies that have evaluated the potential of stun guns to stimulate cardiac muscle. Despite theoretical analyses and animal studies which suggest that stun guns cannot and do not affect the heart, 3 independent investigators have shown cardiac stimulation by stun guns. Additional research studies involving people are needed to resolve the conflicting theoretical and experimental findings and to aid in the design of stun guns that are unable to stimulate the heart.

  3. High Voltage Operation of Helical Pulseline Structures for Ion Acceleration

    CERN Document Server

    Waldron, William; Reginato, Lou

    2005-01-01

    The basic concept for the acceleration of heavy ions using a helical pulseline requires the launching of a high voltage traveling wave with a waveform determined by the beam transport physics in order to maintain stability and acceleration.* This waveform is applied to the front of the helix, creating over the region of the ion bunch a constant axial acceleration electric field that travels down the line in synchronism with the ions. Several methods of driving the helix have been considered. Presently, the best method of generating the waveform and also maintaining the high voltage integrity appears to be a transformer primary loosely coupled to the front of the helix, generating the desired waveform and achieving a voltage step-up from primary to secondary (the helix). This can reduce the drive voltage that must be brought into the helix enclosure through the feedthroughs by factors of 5 or more. The accelerating gradient is limited by the voltage holding of the vacuum insulator, and the material and helix g...

  4. Determination of threshold and maximum operating electric stresses for selected high voltage insulation. Task 3: Investigation of high voltage capacitor insulation

    Science.gov (United States)

    Sosnowski, M.; Eager, G. S., Jr.

    1984-03-01

    The threshold voltage of capacitor insulation was investigated. The experimental work was performed on samples prepared from commercial polypropylene insulated, liquid-filled capacitors. The samples were vacuum-impregnated with the original capacitor insulating liquid obtained from the manufacturer. A limited number of full-size capacitor elements also were tested. Impulse voltage breakdown tests with dc voltage prestressing were performed at room temperature and 75 C. From the results of these tests, the threshold voltage of the samples of the capacitor insulation was determined at both temperatures and that of the whole capacitor elements at room temperature. The threshold voltage of the capacitor insulation was found to be approximately equal to the impulse breakdown voltage. No difference was found between the threshold voltage at room temperature and at 75 C. The threshold voltage of the whole capacitor elements at room temperature was found to be equal to approximately 80% of the threshold voltage of the capacitor insulation samples.

  5. High Input Voltage Discharge Supply for High Power Hall Thrusters Using Silicon Carbide Devices

    Science.gov (United States)

    Pinero, Luis R.; Scheidegger, Robert J.; Aulsio, Michael V.; Birchenough, Arthur G.

    2014-01-01

    A power processing unit for a 15 kW Hall thruster is under development at NASA Glenn Research Center. The unit produces up to 400 VDC with two parallel 7.5 kW discharge modules that operate from a 300 VDC nominal input voltage. Silicon carbide MOSFETs and diodes were used in this design because they were the best choice to handle the high voltage stress while delivering high efficiency and low specific mass. Efficiencies in excess of 97 percent were demonstrated during integration testing with the NASA-300M 20 kW Hall thruster. Electromagnet, cathode keeper, and heater supplies were also developed and will be integrated with the discharge supply into a vacuum-rated brassboard power processing unit with full flight functionality. This design could be evolved into a flight unit for future missions that requires high power electric propulsion.

  6. 30 CFR 75.822 - Underground high-voltage longwall cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage longwall cables. 75... MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.822 Underground high-voltage longwall cables. In addition to the high...

  7. Ultra-compact Marx-type high-voltage generator

    Science.gov (United States)

    Goerz, David A.; Wilson, Michael J.

    2000-01-01

    An ultra-compact Marx-type high-voltage generator includes individual high-performance components that are closely coupled and integrated into an extremely compact assembly. In one embodiment, a repetitively-switched, ultra-compact Marx generator includes low-profile, annular-shaped, high-voltage, ceramic capacitors with contoured edges and coplanar extended electrodes used for primary energy storage; low-profile, low-inductance, high-voltage, pressurized gas switches with compact gas envelopes suitably designed to be integrated with the annular capacitors; feed-forward, high-voltage, ceramic capacitors attached across successive switch-capacitor-switch stages to couple the necessary energy forward to sufficiently overvoltage the spark gap of the next in-line switch; optimally shaped electrodes and insulator surfaces to reduce electric field stresses in the weakest regions where dissimilar materials meet, and to spread the fields more evenly throughout the dielectric materials, allowing them to operate closer to their intrinsic breakdown levels; and uses manufacturing and assembly methods to integrate the capacitors and switches into stages that can be arranged into a low-profile Marx generator.

  8. High impulse voltage and current measurement techniques fundamentals, measuring instruments, measuring methods

    CERN Document Server

    Schon, Klaus

    2013-01-01

    Equipment to be installed in electric power-transmission and distribution systems must pass acceptance tests with standardized high-voltage or high-current test impulses which simulate the stress on the insulation caused by external lightning discharges and switching operations in the grid. High impulse voltages and currents are also used in many other fields of science and engineering for various applications. Therefore, precise impulse-measurement techniques are necessary, either to prevent an over- or understressing of the insulation or to guarantee the effectiveness and quality of the application. The book deals with: principal generator circuits for generating high-voltage and high-current impulses measuring systems and their calibration according to IEC 60060 and IEC 62475 methods of estimating uncertainties of measurement mathematical and experimental basis for characterizing the transfer behavior of spatially extended systems used for measuring fast transients. This book is intended for engineers and ...

  9. Marine High Voltage Power Conditioning and Transmission System with Integrated Storage DE-EE0003640 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Frank Hoffmann, PhD; Aspinall, Rik

    2012-12-10

    Design, Development, and test of the three-port power converter for marine hydrokinetic power transmission. Converter provides ports for AC/DC conversion of hydrokinetic power, battery storage, and a low voltage to high voltage DC port for HVDC transmission to shore. The report covers the design, development, implementation, and testing of a prototype built by PPS.

  10. Digital measurement system for the LHC klystron high voltage modulator.

    CERN Document Server

    Mikkelsen, Anders

    Accelerating voltage in the Large Hadron Collider (LHC) is created by a means of 16 superconducting standing wave RF cavities, each fed by a 400MHz/300kW continuous wave klystron amplifier. Part of the upgrade program for the LHC long shutdown one is to replace the obsolete analogue current and voltage measurement circuitry located in the high voltage bunkers by a new, digital system, using ADCs and optical fibres. A digital measurement card is implemented and integrated into the current HV modulator oil tank (floating at -58kV) and interfaced to the existing digital VME boards collecting the data for several klystrons at the ground potential. Measured signals are stored for the logging, diagnostics and post-mortem analysis purposes.

  11. [Fatal electric arc accidents due to high voltage].

    Science.gov (United States)

    Strauch, Hansjürg; Wirth, Ingo

    2004-01-01

    The frequency of electric arc accidents has been successfully reduced owing to preventive measures taken by the professional association. However, the risk of accidents has continued to exist in private setting. Three fatal electric arc accidents caused by high voltage are reported with reference to the autopsy findings.

  12. Optical Spectra of the High Voltage Erosive Water Discharge

    CERN Document Server

    Pirozerski, A L

    2008-01-01

    In the present paper kinetics of emission spectra of the high voltage erosive water discharge at near ultraviolet and visible spectral ranges has been investigated. Obtained results show a similarity of physical properties of this discharge (and of corresponding plasmoids) to that of some other types of erosional discharges which also result in the formation of dust-gas fireballs.

  13. Intense neutron source: high-voltage power supply specifications

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, A.A.

    1980-08-01

    This report explains the need for and sets forth the electrical, mechanical and safety specifications for a high-voltage power supply to be used with the intense neutron source. It contains sufficient information for a supplier to bid on such a power supply.

  14. Measurements for validation of high voltage underground cable modelling

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Gudmundsdottir, Unnur Stella; Wiechowski, Wojciech Tomasz

    2009-01-01

    This paper discusses studies concerning cable modelling for long high voltage AC cable lines. In investigating the possibilities of using long cables instead of overhead lines, the simulation results must be trustworthy. Therefore a model validation is of great importance. This paper describes...

  15. Space charge accumulation in polymeric high voltage DC cable systems

    NARCIS (Netherlands)

    Bodega, R.

    2006-01-01

    One of the intrinsic properties of the polymeric high voltage (HV) direct current (DC) cable insulation is the accumulation of electrostatic charges. Accumulated charges distort the initial Laplacian distribution of the electric field, leading to a local field enhancement that may cause insulation d

  16. 30 CFR 18.53 - High-voltage longwall mining systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage longwall mining systems. 18.53... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor-starter enclosure, with the exception of a controller on a high-voltage shearer, the disconnect...

  17. 30 CFR 77.802 - Protection of high-voltage circuits; neutral grounding resistors; disconnecting devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of high-voltage circuits; neutral... AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.802 Protection of high-voltage circuits; neutral grounding resistors; disconnecting devices. High-voltage...

  18. 30 CFR 75.810 - High-voltage trailing cables; splices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; splices. 75.810... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.810 High-voltage trailing cables; splices. In the case of high-voltage cables used as...

  19. 30 CFR 75.812-2 - High-voltage power centers and transformers; record of examination.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage power centers and transformers... High-Voltage Distribution § 75.812-2 High-voltage power centers and transformers; record of examination... record shall be kept in a book approved by the Secretary. High-Voltage Longwalls Source: 67 FR 11001,...

  20. 30 CFR 77.804 - High-voltage trailing cables; minimum design requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; minimum design... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.804 High-voltage trailing cables; minimum design requirements. (a) High-voltage trailing cables used in resistance grounded systems shall...

  1. 30 CFR 77.800 - High-voltage circuits; circuit breakers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage circuits; circuit breakers. 77.800... COAL MINES Surface High-Voltage Distribution § 77.800 High-voltage circuits; circuit breakers. High-voltage circuits supplying power to portable or mobile equipment shall be protected by suitable...

  2. An atmospheric pressure plasma source driven by a train of monopolar high voltage pulses superimposed to a dc voltage

    OpenAIRE

    Stoican, O.S.

    2011-01-01

    Abstract An atmospheric pressure plasma source supplied by an electrical circuit consisting of two voltage sources in parallel connection is reported. One of them is a low-power self-oscillating flyback converter which produces negative voltage pulses with an amplitude of several kilovolts. The high voltage pulses are necessary to ignite an electrical discharge between the electrodes at atmospheric pressure. An additional dc source delivering several hundreds of volts at a few hund...

  3. Next generation KATRIN high precision voltage divider for voltages up to 65kV

    CERN Document Server

    Bauer, S; Hochschulz, F; Ortjohann, H -W; Rosendahl, S; Thümmler, T; Schmidt, M; Weinheimer, C

    2013-01-01

    The KATRIN (KArlsruhe TRItium Neutrino) experiment aims to determine the mass of the electron antineutrino with a sensitivity of 200meV by precisely measuring the electron spectrum of the tritium beta decay. This will be done by the use of a retarding spectrometer of the MAC-E-Filter type. To achieve the desired sensitivity the stability of the retarding potential of -18.6kV has to be monitored with a precision of 3ppm over at least two months. Since this is not feasible with commercial devices, two ppm-class high voltage dividers were developed, following the concept of the standard divider for DC voltages of up to 100kV of the Physikalisch-Technische Bundesanstalt (PTB). In order to reach such high accuracies different effects have to be considered. The two most important ones are the temperature dependence of resistance and leakage currents, caused by insulators or corona discharges. For the second divider improvements were made concerning the high-precision resistors and the thermal design of the divider....

  4. Silicon solar cells with high open-circuit voltage

    Science.gov (United States)

    Minnucci, J. A.; Matthei, K. W.; Kirkpatrick, A. R.; Mccrosky, A.

    1980-01-01

    Open-circuit voltages as high as 0.645 V (AM0-25 C) have been obtained by a new process developed for low-resistivity silicon. The method utilizes high-dose phosphorus implantation, followed by furnace annealing and simultaneous oxide growth to form high-efficiency, shallow junctions. The effect of the thermally grown oxide is a reduction of surface recombination velocity; the oxide also acts as a moderately efficient AR coating. Boron doped silicon with resistivities from 0.1 to 0.3 ohm-cm has been processed according to this sequence; results show highest open-circuit voltage is attained with 0.1-ohm-cm starting material. The effects of bandgap narrowing, caused by high doping concentrations in the junction, were also investigated by implanting phosphorus over a wide range of dose levels.

  5. Electronic Current Transducer (ECT) for high voltage dc lines

    Science.gov (United States)

    Houston, J. M.; Peters, P. H., Jr.; Summerayes, H. R., Jr.; Carlson, G. J.; Itani, A. M.

    1980-02-01

    The development of a bipolar electronic current transducer (ECT) for measuring the current in a high voltage dc (HVDC) power line at line potential is discussed. The design and construction of a free standing ECT for use on a 400 kV line having a nominal line current of 2000 A is described. Line current is measured by a 0.0001 ohm shunt whose voltage output is sampled by a 14 bit digital data link. The high voltage interface between line and ground is traversed by optical fibers which carry digital light signals as far as 300 m to a control room where the digital signal is converted back to an analog representation of the shunt voltage. Two redundant electronic and optical data links are used in the prototype. Power to operate digital and optical electronics and temperature controlling heaters at the line is supplied by a resistively and capacitively graded 10 stage cascade of ferrite core transformers located inside the hollow, SF6 filled, porcelain support insulator. The cascade is driven by a silicon controlled rectifier inverter which supplies about 100 W of power at 30 kHz.

  6. 30 CFR 75.705-2 - Repairs to energized surface high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Repairs to energized surface high-voltage lines... Repairs to energized surface high-voltage lines. An energized high-voltage surface line may be repaired... on power circuits with a phase-to-phase nominal voltage no greater than 15,000 volts; (3)...

  7. 30 CFR 77.704-2 - Repairs to energized high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Repairs to energized high-voltage lines. 77.704... UNDERGROUND COAL MINES Grounding § 77.704-2 Repairs to energized high-voltage lines. An energized high-voltage... repairs will be performed on power circuits with a phase-to-phase nominal voltage no greater than...

  8. A novel high-voltage device structure with an N+ ring in substrate and the breakdown voltage model

    Institute of Scientific and Technical Information of China (English)

    Li Qi; Zhu Jinluan; Wang Weidong; Yue Hongwei; Jin Liangnian

    2011-01-01

    A novel high-voltage device structure with a floating heavily doped N+ ring embedded in the substrate is reported,which is called FR LDMOS.When the N+ ring is introduced in the device substrate,the electric field peak of the main junction is reduced due to the transfer of the voltage from the main junction to the N+ ring junction,and the vertical breakdown characteristic is improved significantly.Based on the Poisson equation of cylindrical coordinates,a breakdown voltage model is developed.The numerical results indicate that the breakdown voltage of the proposed device is increased by 56% in comparison to conventional LDMOS.

  9. An ultra-low noise, high-voltage piezo driver

    CERN Document Server

    Pisenti, N C; Reschovsky, B J; Barker, D S; Campbell, G K

    2016-01-01

    We present an ultra-low noise, high-voltage driver suited for use with piezoelectric actuators and other low-current applications. The architecture uses a flyback switching regulator to generate up to 250V in our current design, with an output of 1 kV or more possible with small modifications. A high slew-rate op-amp suppresses the residual switching noise, yielding a total RMS noise of $\\approx 100\\mu$V (1 Hz--100 kHz). A low-voltage ($\\pm 10$V), high bandwidth signal can be summed with unity gain directly onto the output, making the driver well-suited for closed-loop feedback applications. Digital control enables both repeatable setpoints and sophisticated control logic, and the circuit consumes less than 150mA at $\\pm 15$V.

  10. 变频串联谐振技术在高压电缆交接试验中的应用%Application of Variable-Frequency Series Resonance Technology in Hand-over Acceptance Tests of High Voltage Power Cables

    Institute of Scientific and Technical Information of China (English)

    赵金明; 段肖华

    2012-01-01

    变频串联谐振耐压试验技术是当前高压试验的一种新方法.变频串联谐振的原理、组成及优点等进行了阐述,并对此技术在高压电缆交接试验中的应用进行了分析探讨,通过实例表明:此方法是科学、实用、高效的.%Variable-frequency series resonance withstand voltage technology is a new method widely in high voltage tests. This paper introduces the principle, composition and advantages of the technology, and discusses its applications in the acceptance tests of high voltage power cables. The actual examples show that the method is scientific and practical and efficient.

  11. High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    Science.gov (United States)

    Shimer, Daniel W.; Lange, Arnold C.

    1995-01-01

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  12. High Output Voltage Based Multiphase Step-Up DC-DC Converter Topology with Voltage Doubler Rectifiers

    Directory of Open Access Journals (Sweden)

    Liao Xiaozhong

    2013-02-01

    Full Text Available High Output Voltage Based Multiphase Step-Up DC-DC Converter topology with voltage doubler rectifiers is presented in this paper. High output voltage is obtained due to the series combination of voltage doubler rectifiers on the secondary side of high frequency transformers. This topology is useful in the application where the output voltage is greater than the input. The two loop control strategy has been developed in order to analyze the stable and effective working of the converter topology. Therefore the working mode analysis of the converter topology has been described in detail. The multiphase step-up DC-DC converter topology is first simulated on MATLAB and then a prototype has been designed in order to verify the simulation and experimental results. Finally the simulation and experimental results are found to be satisfactory.

  13. Bottlenecks reduction using superconductors in high voltage transmission lines

    Directory of Open Access Journals (Sweden)

    Daloub Labib

    2016-01-01

    Full Text Available Energy flow bottlenecks in high voltage transmission lines known as congestions are one of the challenges facing power utilities in fast developing countries. Bottlenecks occur in selected power lines when transmission systems are operated at or beyond their transfer limits. In these cases, congestions result in preventing new power supply contracts, infeasibility in existing contracts, price spike and market power abuse. The “Superconductor Technology” in electric power transmission cables has been used as a solution to solve the problem of bottlenecks in energy transmission at high voltage underground cables and overhead lines. The increase in demand on power generation and transmission happening due to fast development and linked to the intensive usage of transmission network in certain points, which in turn, lead to often frequent congestion in getting the required power across to where it is needed. In this paper, a bottleneck in high voltage double overhead transmission line with Aluminum Conductor Steel Reinforced was modeled using conductor parameters and replaced by Gap-Type Superconductor to assess the benefit of upgrading to higher temperature superconductor and obtain higher current carrying capacity. This proved to reduce the high loading of traditional aluminum conductors and allow more power transfer over the line using superconductor within the same existing right-of-way, steel towers, insulators and fittings, thus reducing the upgrade cost of building new lines.

  14. A Review of High Voltage Drive Amplifiers for Capacitive Actuators

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.

    2012-01-01

    This paper gives an overview of the high voltage amplifiers, which are used to drive capacitive actuators. The amplifiers for both piezoelectric and DEAP (dielectric electroactive polymer) actuator are discussed. The suitable topologies for driving capacitive actuators are illustrated in detail, ......, including linear as well as switched mode amplifiers. In the past much attention has been paid on the driver for piezoelectric actuator. As DEAP is a type of new material, there is not much literature reference for it.......This paper gives an overview of the high voltage amplifiers, which are used to drive capacitive actuators. The amplifiers for both piezoelectric and DEAP (dielectric electroactive polymer) actuator are discussed. The suitable topologies for driving capacitive actuators are illustrated in detail...

  15. Design and validation of a high-voltage levitation circuit for electrostatic accelerometers.

    Science.gov (United States)

    Li, G; Wu, S C; Zhou, Z B; Bai, Y Z; Hu, M; Luo, J

    2013-12-01

    A simple high-voltage circuit with a voltage range of 0 to 900 V and an open-loop bandwidth of 11 kHz is realized by using an operational amplifier and a MOSFET combination. The circuit is used for the levitation of a test mass of 71 g, suspended below the top-electrodes with a gap distance of 57 μm, so that the performance of an electrostatic accelerometer can be tested on the ground. The translation noise of the accelerometer, limited by seismic noise, is about 4 × 10(-8) m/s(2)/Hz(1/2) at 0.1 Hz, while the high-voltage coupling noise is one-order of magnitude lower.

  16. High voltage generator circuit with low power and high efficiency applied in EEPROM

    Institute of Scientific and Technical Information of China (English)

    Liu Yan; Zhang Shilin; Zhao Yiqiang

    2012-01-01

    This paper presents a low power and high efficiency high voltage generator circuit embedded in electrically erasable programmable read-only memory (EEPROM).The low power is minimized by a capacitance divider circuit and a regulator circuit using the controlling clock switch technique.The high efficiency is dependent on the zero threshold voltage (Vth) MOSFET and the charge transfer switch (CTS) charge pump.The proposed high voltage generator circuit has been implemented in a 0.35μm EEPROM CMOS process.Measured results show that the proposed high voltage generator circuit has a low power consumption of about 150.48 μW and a higher pumping efficiency (83.3%) than previously reported circuits.This high voltage generator circuit can also be widely used in low-power flash devices due to its high efficiency and low power dissipation.

  17. High voltage systems (tube-type microwave)/low voltage system (solid-state microwave) power distribution

    Science.gov (United States)

    Nussberger, A. A.; Woodcock, G. R.

    1980-01-01

    SPS satellite power distribution systems are described. The reference Satellite Power System (SPS) concept utilizes high-voltage klystrons to convert the onboard satellite power from dc to RF for transmission to the ground receiving station. The solar array generates this required high voltage and the power is delivered to the klystrons through a power distribution subsystem. An array switching of solar cell submodules is used to maintain bus voltage regulation. Individual klystron dc voltage conversion is performed by centralized converters. The on-board data processing system performs the necessary switching of submodules to maintain voltage regulation. Electrical power output from the solar panels is fed via switch gears into feeder buses and then into main distribution buses to the antenna. Power also is distributed to batteries so that critical functions can be provided through solar eclipses.

  18. Rad-Hard, Miniaturized, Scalable, High-Voltage Switching Module for Power Applications Rad-Hard, Miniaturized

    Science.gov (United States)

    Adell, Philippe C.; Mojarradi, Mohammad; DelCastillo, Linda Y.; Vo, Tuan A.

    2011-01-01

    A paper discusses the successful development of a miniaturized radiation hardened high-voltage switching module operating at 2.5 kV suitable for space application. The high-voltage architecture was designed, fabricated, and tested using a commercial process that uses a unique combination of 0.25 micrometer CMOS (complementary metal oxide semiconductor) transistors and high-voltage lateral DMOS (diffusion metal oxide semiconductor) device with high breakdown voltage (greater than 650 V). The high-voltage requirements are achieved by stacking a number of DMOS devices within one module, while two modules can be placed in series to achieve higher voltages. Besides the high-voltage requirements, a second generation prototype is currently being developed to provide improved switching capabilities (rise time and fall time for full range of target voltages and currents), the ability to scale the output voltage to a desired value with good accuracy (few percent) up to 10 kV, to cover a wide range of high-voltage applications. In addition, to ensure miniaturization, long life, and high reliability, the assemblies will require intensive high-voltage electrostatic modeling (optimized E-field distribution throughout the module) to complete the proposed packaging approach and test the applicability of using advanced materials in a space-like environment (temperature and pressure) to help prevent potential arcing and corona due to high field regions. Finally, a single-event effect evaluation would have to be performed and single-event mitigation methods implemented at the design and system level or developed to ensure complete radiation hardness of the module.

  19. Design and Implementation of a High-Voltage Generator with Output Voltage Control for Vehicle ER Shock-Absorber Applications

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2013-01-01

    Full Text Available A self-oscillating high-voltage generator is proposed to supply voltage for a suspension system in order to control the damping force of an electrorheological (ER fluid shock absorber. By controlling the output voltage level of the generator, the damping force in the ER fluid shock absorber can be adjusted immediately. The shock absorber is part of the suspension system. The high-voltage generator drives a power transistor based on self-excited oscillation, which converts dc to ac. A high-frequency transformer with high turns ratio is used to increase the voltage. In addition, the system uses the car battery as dc power supply. By regulating the duty cycle of the main switch in the buck converter, the output voltage of the buck converter can be linearly adjusted so as to obtain a specific high voltage for ER. The driving system is self-excited; that is, no additional external driving circuit is required. Thus, it reduces cost and simplifies system structure. A prototype version of the actual product is studied to measure and evaluate the key waveforms. The feasibility of the proposed system is verified based on experimental results.

  20. High Voltage Coaxial Vacuum Gap Breakdown for Pulsed Power Liners

    Science.gov (United States)

    Cordaro, Samuel; Bott-Suzuki, Simon; Caballero Bendixsen, Luis Sebastian

    2015-11-01

    The dynamics of Magnetized Liner Inertial Fusion (MagLIF)1, are presently under detailed study at Sandia National Laboratories. Alongside this, a comprehensive analysis of the influence of the specific liner design geometry in the MagLIF system on liner initiation is underway in the academic community. Recent work at UC San Diego utilizes a high voltage pulsed system (25kV, 150ns) to analyze the vacuum breakdown stage of liner implosion. Such experimental analyses are geared towards determining how the azimuthal symmetry of coaxial gap breakdown affect plasma initiation within the liner. The final aim of the experimental analysis is to assess to what scale symmetry remains important at high (MV) voltages. An analysis of the above will utilize plasma self-emission via optical MCP, current measurements, voltage measurements near the gap, exact location of breakdown via 2D b-dot probe triangulation, as well as measuring the evolution of the B-field along the length of the liner via b-dot array. Results will be discussed along with analytical calculations of breakdown mechanisms

  1. Modeling of High-voltage Breakdown in Helium

    Science.gov (United States)

    Xu, Liang; Khrabrov, Alexander; Kaganovich, Igor; Sommerer, Timothy

    2016-09-01

    We investigate the breakdown in extremely high reduced electric fields (E/N) between parallel-plate electrodes in helium. The left branch of the Paschen curve in the voltage range of 20-350kV and inter-electrode gap range of 0.5-3.5cm is studied analytically and with Monte-Carlo/PIC simulations. The model incorporates electron, ion, and fast neutral species whose energy-dependent anisotropic scattering, as well as backscattering at the electrodes, is carefully taken into account. Our model demonstrates that (1) anisotropic scattering is indispensable for producing reliable results at such high voltage and (2) due to the heavy species backscattered at cathode, breakdown can occur even without electron- and ion-induced ionization of the background gas. Fast atoms dominate in the breakdown process more and more as the applied voltage is increased, due to their increasing ionization cross-section and to the copious flux of energetic fast atoms generated in charge-exchange collisions.

  2. Control system design of high-voltage live cleaning robot based on security

    Institute of Scientific and Technical Information of China (English)

    谢霄鹏; 夏红卫; 杨汝清

    2004-01-01

    High-voltage live cleaning robot works in the hot-line environment (220 kV/330 kV), and so the safety of its application and equipment is most important. In terms of safety, the designs of robot mechanism and control system have been discussed, and the test data are given in control system of model machine. The model machine of high-voltage live cleaning robot can meet the need of cleaning basically in common condition. From manual operation to automation, the cleaning efficiency is improved. The robot can decrease amount of work, and ensure the security. Among high-voltage live cleaning equipment in China, the cleaning robot is advanced in automation and intelligence.

  3. Experimental validation of a high voltage pulse measurement method.

    Energy Technology Data Exchange (ETDEWEB)

    Cular, Stefan; Patel, Nishant Bhupendra; Branch, Darren W.

    2013-09-01

    This report describes X-cut lithium niobates (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensors U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

  4. New drain current model for nano-meter MOS transistors on-chip threshold voltage test

    NARCIS (Netherlands)

    Wan, Jinbo; Kerkhoff, Hans G.

    2015-01-01

    Traditional reliability tests use complicated equipment, like probe stations and semiconductor parameter analyzers, to measure changes in transistors' threshold voltages, which are both expensive and time consuming. This paper provides an idea to test the threshold voltage with existing low-to-moder

  5. Electronically Tunable High Input Impedance Voltage-Mode Multifunction Filter

    Science.gov (United States)

    Chen, Hua-Pin; Yang, Wan-Shing

    A novel electronically tunable high input impedance voltage-mode multifunction filter with single inputs and three outputs employing two single-output-operational transconductance amplifiers, one differential difference current conveyor and two capacitors is proposed. The presented filter can be realized the highpass, bandpass and lowpass functions, simultaneously. The input of the filter exhibits high input impedance so that the synthesized filter can be cascaded without additional buffers. The circuit needs no any external resistors and employs two grounded capacitors, which is suitable for integrated circuit implementation.

  6. A magnesium–sodium hybrid battery with high operating voltage

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Hui; Li, Yifei; Liang, Yanliang; Li, Guosheng; Sun, Cheng-Jun; Ren, Yang; Lu, Yuhao; Yao, Yan

    2016-06-10

    We report a high performance magnesium-sodium hybrid battery utilizing a magnesium-sodium dual-salt electrolyte, a magnesium anode, and a Berlin green cathode. The cell delivers an average discharge voltage of 2.2 V and a reversible capacity of 143 mAh g-1. We also demonstrate the cell with an energy density of 135 Wh kg-1 and a high power density of up to 1.67 kW kg-1.

  7. Efficient Parametric Identification Method for High Voltage Pulse Transformers

    CERN Document Server

    Aguglia, D; Viarouge, P; Cros, J

    2014-01-01

    This paper presents a new identification method for a pulse transformer equivalent circuit. It is based on an analytical approximation of the frequency-domain impedance data derived from a no-load test with open-circuited secondary winding and only requires measurements of primary current and voltage without phase data. Compared with time consuming and complex methods based on off-line non-linear identification procedures, this simple method also gives an estimation of the error on the identified parameters. The method is validated on an existing pulse transformer.

  8. New perspectives in vacuum high voltage insulation. II. Gas desorption

    CERN Document Server

    Diamond, W T

    1998-01-01

    An examination has been made of gas desorption from unbaked electrodes of copper, niobium, aluminum, and titanium subjected to high voltage in vacuum. It has been shown that the gas is composed of water vapor, carbon monoxide, and carbon dioxide, the usual components of vacuum outgassing, plus an increased yield of hydrogen and light hydrocarbons. The gas desorption was driven by anode conditioning as the voltage was increased between the electrodes. The gas is often desorbed as microdischarges-pulses of a few to hundreds of microseconds-and less frequently in a more continuous manner without the obvious pulsed structure characteristic of microdischarge activity. The quantity of gas released was equivalent to many monolayers and consisted mostly of neutral molecules with an ionic component of a few percent. A very significant observation was that the gas desorption was more dependent on the total voltage between the electrodes than on the electric field. It was not triggered by field-emitted electrons but oft...

  9. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    Directory of Open Access Journals (Sweden)

    C. Yong-Nong

    2013-03-01

    Full Text Available In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The powersupply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to theindispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer needconsidering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, butalso parasitic capacitance resulted from the insulation wrappings on the high-voltage side. This research exhibits asimple approach to measuring equivalent circuit parameters of the high-frequency, high-voltage transformer with straycapacitance being introduced into the conventional modeling. The proposed modeling scheme provides not only aprecise measurement procedure but also effective design information for series-load resonant converter. The plasmadischarging plate is designed as part of the electric circuit in the series load-resonant converter and the circuit modelof the plasma discharging plate is also conducted as well. Thus, the overall model of the high-voltage plasmagenerator is built and the designing procedures for appropriate selections of the corresponding resonant-circuitparameters can be established. Finally, a high-voltage plasma generator with 220V, 60Hz, and 1kW input, along witha 22 kHz and over 8kV output, is realized and implemented.

  10. Unlikely Combination of Experiments With a Novel High-Voltage CIGS Photovoltaic Array: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    del Cueto, J. A.; Sekulic, B. R.

    2006-05-01

    A new high-voltage array comprising bipolar strings of copper indium gallium diselenide (CIGS) photovoltaic (PV) modules was inaugurated in 2005. It is equipped with a unique combination of tests, which likely have never before been deployed simultaneously within a single array: full current-voltage (I-V) traces, high-voltage leakage current measurements, and peak-power tracking or temporal stepped-bias profiling. The array nominally produces 1 kW power at 1 sun. The array's electrical characteristics are continuously monitored and controlled with a programmable electronic load interfaced to a data acquisition system (DAS), that also records solar and meteorological data. The modules are mounted with their frames electrically isolated from earth ground, in order to facilitate measurement of the leakage currents that arise between the high voltage bias developed in the series-connected cells and modules and their mounting frames. Because the DAS can perform stepped biasing of the array as a function of time, synchronous detection of the leakage current data with alternating bias is available. Leakage current data and their dependence on temperature and voltage are investigated. Array power data are analyzed across a wide range of varying illuminations and temperatures from the I-V traces. Array performance is also analyzed from an energy output perspective using peak-power tracking data.

  11. Connection for transfer of Liquid Nitrogen from High Voltage to ground potential

    DEFF Research Database (Denmark)

    Rasmussen, Claus Nygaard; Hansen, Finn; Willén, Dag

    2001-01-01

    In order to operate a superconducting cable conductor it must be kept at a cryogenic temperature (e.g. using liquid nitrogen). The superconducting cable conductor is at high voltage and the cooling equipment is kept at ground potential. This requires a thermally insulating connection that is also...... strength. However, samples of ExpancelÒ (polymer foam) have recently proved to withstand large electrical fields at room temperature as well as at cryogenic temperatures. In this work, two prototype devices have been tested with respect to the partial discharge inception voltage, thermal insulation...

  12. A novel high voltage start up circuit for an integrated switched mode power supply

    Energy Technology Data Exchange (ETDEWEB)

    Hu Hao; Chen Xingbi, E-mail: huhao21@uestc.edu.c [State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054 (China)

    2010-09-15

    A novel high voltage start up circuit for providing an initial bias voltage to an integrated switched mode power supply (SMPS) is presented. An enhanced mode VDMOS transistor, the gate of which is biased by a floating p-island, is used to provide start up current and sustain high voltage. An NMOS transistor having a high source to ground breakdown voltage is included to extend the bias voltage range to the SMPS. Simulation results indicate that the high voltage start up circuit can start and restart as designed. The proposed structure is believed to be more energy saving and cost-effective compared with other solutions. (semiconductor devices)

  13. SEMICONDUCTOR DEVICES: A novel high voltage start up circuit for an integrated switched mode power supply

    Science.gov (United States)

    Hao, Hu; Xingbi, Chen

    2010-09-01

    A novel high voltage start up circuit for providing an initial bias voltage to an integrated switched mode power supply (SMPS) is presented. An enhanced mode VDMOS transistor, the gate of which is biased by a floating p-island, is used to provide start up current and sustain high voltage. An NMOS transistor having a high source to ground breakdown voltage is included to extend the bias voltage range to the SMPS. Simulation results indicate that the high voltage start up circuit can start and restart as designed. The proposed structure is believed to be more energy saving and cost-effective compared with other solutions.

  14. Development of a Marx-coupled trigger generator with high voltages and low time delay

    Science.gov (United States)

    Hu, Yixiang; Zeng, Jiangtao; Sun, Fengju; Cong, Peitian; Su, Zhaofeng; Yang, Shi; Zhang, Xinjun; Qiu, Ai'ci

    2016-10-01

    Coupled by the Marx of the "JianGuang-I" facility, a high voltage, low time-delay trigger generator was developed. Working principles of this trigger generator and its key issues were described in detail. Structures of this generator were also carefully designed and optimized. Based on the "JianGuang-I" Marx generator, a test stand was established. And a series of experiment tests were carried out to the study performance of this trigger generator. Experiment results show that the output voltage of this trigger generator can be continuously adjusted from 58 kV to 384 kV. The time delay (from the beginning of the Marx-discharging pulse to the time that the output pulse of the trigger generator arises) of this trigger pulse is about 200 ns and its peak time (0%˜100%) is less than 50 ns. Experiment results also indicate that the time-delay jitter of trigger voltages decreases rapidly with the increase in the peak voltage of trigger pulses. When the trigger voltage is higher than 250 kV, the time-delay jitters (the standard deviation) are less than 7.7 ns.

  15. A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

    Science.gov (United States)

    Pei, Chengquan; Tian, Jinshou; Liu, Zhen; Qin, Hong; Wu, Shengli

    2017-04-01

    A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.

  16. Properties of Polymer Composites Used in High-Voltage Applications

    Directory of Open Access Journals (Sweden)

    Ilona Pleşa

    2016-04-01

    Full Text Available The present review article represents a comprehensive study on polymer micro/nanocomposites that are used in high-voltage applications. Particular focus is on the structure-property relationship of composite materials used in power engineering, by exploiting fundamental theory as well as numerical/analytical models and the influence of material design on electrical, mechanical and thermal properties. In addition to describing the scientific development of micro/nanocomposites electrical features desired in power engineering, the study is mainly focused on the electrical properties of insulating materials, particularly cross-linked polyethylene (XLPE and epoxy resins, unfilled and filled with different types of filler. Polymer micro/nanocomposites based on XLPE and epoxy resins are usually used as insulating systems for high-voltage applications, such as: cables, generators, motors, cast resin dry-type transformers, etc. Furthermore, this paper includes ample discussions regarding the advantages and disadvantages resulting in the electrical, mechanical and thermal properties by the addition of micro- and nanofillers into the base polymer. The study goals are to determine the impact of filler size, type and distribution of the particles into the polymer matrix on the electrical, mechanical and thermal properties of the polymer micro/nanocomposites compared to the neat polymer and traditionally materials used as insulation systems in high-voltage engineering. Properties such as electrical conductivity, relative permittivity, dielectric losses, partial discharges, erosion resistance, space charge behavior, electric breakdown, tracking and electrical tree resistance, thermal conductivity, tensile strength and modulus, elongation at break of micro- and nanocomposites based on epoxy resin and XLPE are analyzed. Finally, it was concluded that the use of polymer micro/nanocomposites in electrical engineering is very promising and further research work

  17. DEMONSTRATION BULLETIN: HIGH VOLTAGE ELECTRON BEAM TECHNOLOGY - HIGH VOLTAGE ENVIRONMENTAL APPLICATIONS, INC.

    Science.gov (United States)

    The high energy electron beam irradiation technology is a low temperature method for destroying complex mixtures of hazardous organic chemicals in solutions containing solids. The system consists of a computer-automated, portable electron beam accelerator and a delivery system. T...

  18. Optical cable in lightning wires of high voltage networks. Optische kabel in bliksemdraden van hoogspanningsnetten

    Energy Technology Data Exchange (ETDEWEB)

    Van Eck, J.T. (NKF Kabel BV, Delft (Netherlands))

    1990-12-01

    The design criteria for OPGW cables, various solutions available in the market and the particular choice of NKF Kabel BV for this type of cable are described. The test program performed to verify the design as well as the results of a number of complementary tests are given. Furthermore some practical considerations with respect to the installation of said cables in the high voltage network have been drawn up. 12 ills., 8 tabs.

  19. High Voltage Operation of heavily irradiated silicon microstrip detectors

    CERN Document Server

    Gu, W H; Angarano, M M; Bader, A; Biggeri, U; Boemi, D; Braibant, S; Breuker, H; Bruzzi, Mara; Caner, A; Catacchini, E; Civinini, C; Creanza, D; D'Alessandro, R; Demaria, N; Eklund, C; Peisert, Anna; Feld, L; Fiore, L; Focardi, E; Fürtjes, A; Glessing, B; Hall, G; Hammerstrom, R; Dollan, Ralph; Huhtinen, M; Karimäki, V; König, S; Lenzi, M; Lübelsmeyer, K; Maggi, G; Mannelli, M; Marchioro, A; Mariotti, C; Mättig, P; McEvoy, B; Meschini, M; My, S; Pandoulas, D; Parrini, G; Pieri, M; Dollan, Ralph; Potenza, R; Raso, G; Raymond, M; Schmitt, B; Selvaggi, G; Siedling, R; Silvestris, L; Skog, K; Stefanini, G; Tempesta, P; Tricomi, A; Watts, S; Wittmer, B; De Palma, M

    1999-01-01

    We discuss the results obtained from the R&D studies, done within the CMS experiment at LHC related to the behaviour of silicon microstrip prototype detectors when they are operated at high bias voltages before and after heavy irradiation, simulating up to 10 years of LHC running conditions. We have found detectors from several manufacturesrs that are able to work at V_bias > 500 Volts before and after the irradiation procedure, maintaining an acceptable performance with S/N > 14, efficiency close to 100% and few ghost hits.

  20. A High-Voltage Bipolar Transconductance Amplifier for Electrotactile Stimulation

    Science.gov (United States)

    Schaning, Matthew A.; Kaczmarek, Kurt A.

    2008-01-01

    This article describes a high-performance transconductance amplifier specifically designed for electrotactile (electrocutaneous) stimulation. It enables voltages up to ±600 V to be produced at the output which will allow the psychophysiological performance associated with stimulation of the fingertip using various stimulation waveforms to be studied more thoroughly. The design has a transconductance of up to 20 mA/V, an 8.8-MΩ output resistance, and can provide output currents up to ±20 mA. A complete schematic diagram is presented along with a discussion of theory of operation and safety issues as well as performance and derating plots from the implemented design. PMID:18838369

  1. High Luminosity LHC matching section layout vs crab cavity voltage

    CERN Document Server

    Dalena, B; Chance, A; De Maria, R; Fartoukh, S

    2013-01-01

    In the framework of the HiLumi-LHC project we present a new possible variant for the layout of the LHC matching section located in the high luminosity insertions. This layout is optimized to reduce the demand on the voltage of the crab cavities, while substantially improving the optics squeeze-ability, both in ATS [1] and non-ATS mode. This new layout will be described in details together with its performance figures in terms of mechanical acceptance, chromatic properties and optics flexibility.

  2. Simulation Research of Transient Over-voltage on High-voltage Shunt Capacitor Banks

    Institute of Scientific and Technical Information of China (English)

    HU Quan-wei; ZHOU Xing-xing; SI Wen-rong; ZHANG Yang; LI Jur-hao; LI Yan-ming

    2011-01-01

    With the development of power systems,a large number of shunt capacitors are used to improve power quality in the distribution network.The shunt capacitor banks are operated much frequently,as a result,the capacitor banks will bear large numbers of over-voltage inevitably.If the over-voltage exceeds certain amplitude,the capacitor will be damaged.This paper aims at the capacitor banks in the 35 kV side of Shanghai Xu-xing 500 kV substation,and applies ATP-EMTP to simulate the over-voltages generated by operating the switches under different angles of the source.Finally,according to the results of simulation and theoretical analysis,a best choice (i.e.angles of the source) to switch on capacitor banks is proposed.In this case the over-voltage on the capacitor will be limited to lowest.

  3. Stress-dependent voltage offsets from polymer insulators used in rock mechanics and material testing

    Science.gov (United States)

    Carlson, G. G.; Dahlgren, R.; Vanderbilt, V. C.; Johnston, M. J.; Dunson, C.; Gray, A.; Freund, F.

    2013-12-01

    Dielectric insulators are used in a variety of laboratory settings when performing experiments in rock mechanics, petrology, and electromagnetic studies of rocks in the fields of geophysics, material science, and civil engineering. These components may be used to electrically isolate geological samples from the experimental equipment, to perform a mechanical compliance function between brittle samples and the loading equipment, to match ultrasonic transducers, or perform other functions. In many experimental configurations the insulators bear the full brunt of force applied to the sample but do not need to withstand high voltages, therefore the insulators are often thin sheets of mechanically tough polymers. From an instrument perspective, transduction from various types of mechanical perturbation has been qualitatively compared for a number of polymers [1, 2] and these error sources are readily apparent during high-impedance measurements if not mitigated. However even when following best practices, a force-dependent voltage signal still remains and its behavior is explored in this presentation. In this experiment two thin sheets (0.25 mm) of high-density polyethylene (HDPE) were set up in a stack, held alternately between three aluminum bars; this stack was placed on the platen of a 60T capacity hydraulic testing machine. The surface area, A, over which the force is applied to the PE sheets in this sandwich is roughly 40 square cm, each sheet forming a parallel-plate capacitor having roughly 320 pF [3], assuming the relative dielectric permittivity of PE is ~2.3. The outer two aluminum bars were connected to the LO input of the electrometer and the central aluminum bar was connected to the HI input of a Keithley model 617 electrometer. Once the stack is mechanically well-seated with no air gaps, the voltage offset is observed to be a linear function of the baseline voltage for a given change in applied force. For a periodically applied force of 66.7 kN the voltage

  4. Development of ultra-short high voltage pulse technology using magnetic pulse compression

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Byung Heon; Kim, S. G.; Nam, S. M.; Lee, B. C.; Lee, S. M.; Jeong, Y. U.; Cho, S. O.; Jin, J. T.; Choi, H. L

    1998-01-01

    The control circuit for high voltage switches, the saturable inductor for magnetic assist, and the magnetic pulse compression circuit were designed, constructed, and tested. The core materials of saturable inductors in magnetic pulse compression circuit were amorphous metal and ferrite and total compression stages were 3. By the test, in high repetition rate, high pulse compression were certified. As a result of this test, it became possible to increase life-time of thyratrons and to replace thyratrons by solid-state semiconductor switches. (author). 16 refs., 16 tabs.

  5. Survey of high voltage electron microscopy worldwide in 1998.

    Energy Technology Data Exchange (ETDEWEB)

    Allen, C. W.

    1998-03-05

    High voltage TEMs were introduced commercially thirty years ago, with the installations of 500 kV Hitachi instruments at the Universities of Nagoya and Tokyo. Since that time 53 commercial instruments, having maximum accelerating potentials of 0.5-3.5 MV, will have been delivered by the end of 1998. Table 1 summarizes the sites and some information regarding those HVEMS which are available in 1998. This corrects, updates and expands an earlier report of this sort [2]. There have been three commercial HVEM manufacturers: AEI (UK), Hitachi and JEOL (Japan). The proportion of the total number of HVEMS produced by each manufacturer is similar to that reflected in Table 1: AEI and Kratos/AEI (12), Hitachi (20) and JEOL (21). The term Kratos/AEI refers to instruments delivered after the takeover of AEI by Grates in the late 1970's. In Table 1 only maximum accelerating potentials are listed, which is generally also the design value for which the resolution for imaging was optimized. It is important to realize that in many applications, especially those studying irradiation effects, much lower voltages may be employed somewhat routinely to minimize atom displacements by the incident electron beam during analysis. These minimum values range from 100 kV for the AEI and Kratos/AEI instruments to typically 400 kV for the current generation of atomic resolution instruments, the latter being well above the thresholds for displacement in light elements such as Al and Si and for displacement of anions in many ceramic materials such as the high Tc superconductors, for example. An additional potential problem is electron-induced sputtering and differential sputtering (unequal sputtering rates in multicomponent materials), especially when accurate elemental microanalysis is being attempted. These same issues may arise for intermediate voltage TEMs as well, of course.

  6. 30 CFR 77.704-1 - Work on high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines. 77.704-1 Section 77... MINES Grounding § 77.704-1 Work on high-voltage lines. (a) No high-voltage line shall be regarded as... provided in § 77.103) that such high-voltage line has been deenergized and grounded. Such qualified...

  7. Novel Interleaved Converter with Extra-High Voltage Gain to Process Low-Voltage Renewable-Energy Generation

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2016-10-01

    Full Text Available This paper presents a novel interleaved converter (NIC with extra-high voltage gain to process the power of low-voltage renewable-energy generators such as photovoltaic (PV panel, wind turbine, and fuel cells. The NIC can boost a low input voltage to a much higher voltage level to inject renewable energy to DC bus for grid applications. Since the NIC has two circuit branches in parallel at frond end to share input current, it is suitable for high power applications. In addition, the NIC is controlled in an interleaving pattern, which has the advantages that the NIC has lower input current ripple, and the frequency of the ripple is twice the switching frequency. Two coupled inductors and two switched capacitors are incorporated to achieve a much higher voltage gain than conventional high step-up converters. The proposed NIC has intrinsic features such as leakage energy totally recycling and low voltage stress on power semiconductor. Thorough theoretical analysis and key parameter design are presented in this paper. A prototype is built for practical measurements to validate the proposed NIC.

  8. Study of DC Circuit Breaker of H2-N2 Mixture Gas for High Voltage

    Science.gov (United States)

    Shiba, Yuji; Morishita, Yukinaga; Kaneko, Shuhei; Okabe, Shigemitsu; Mizoguchi, Hitoshi; Yanabu, Satoru

    Global warming caused by CO2 etc. is a field where the concern is very high. Especially, automobile emissions are problem for it. Therefore, the hybrid car is widely development and used recently. Hybrid car used electric power and gasoline. So, the car reduces CO2. Hybrid car has engine and motor. To rotate the motor, hybrid car has battery. This battery is large capacity. Therefore, the relay should interrupt high DC current for the switch of the motor and the engine. So, hybrid car used hydrogen gas filling relay We studied interruption test for the research of a basic characteristic of hydrogen gas. DC current has not current zero point. So, it is necessary to make the current zero by high arc voltage and forcible current zero point. The loss coefficient and arc voltage of hydrogen is high. Therefore, we studied interruption test for used high arc voltage. We studied interruption test and dielectric breakdown test of air, pure Hydrogen, and Hydrogen- nitrogen mixture gas. As a result, we realized H2-N2(80%-20%) is the best gas.

  9. A high voltage ratio and low ripple interleaved DC-DC converter for fuel cell applications.

    Science.gov (United States)

    Chang, Long-Yi; Chao, Kuei-Hsiang; Chang, Tsang-Chih

    2012-01-01

    This paper proposes a high voltage ratio and low ripple interleaved boost DC-DC converter, which can be used to reduce the output voltage ripple. This converter transfers the low DC voltage of fuel cell to high DC voltage in DC link. The structure of the converter is parallel with two voltage-doubler boost converters by interleaving their output voltages to reduce the voltage ripple ratio. Besides, it can lower the current stress for the switches and inductors in the system. First, the PSIM software was used to establish a proton exchange membrane fuel cell and a converter circuit model. The simulated and measured results of the fuel cell output characteristic curve are made to verify the correctness of the established simulation model. In addition, some experimental results are made to validate the effectiveness in improving output voltage ripple of the proposed high voltage ratio interleaved boost DC-DC converters.

  10. Effects of vinylene carbonate on high temperature storage of high voltage Li-ion batteries

    Science.gov (United States)

    Eom, Ji-Yong; Jung, In-Ho; Lee, Jong-Hoon

    The effects of vinylene carbonate (VC) on high temperature storage of high voltage Li-ion batteries are investigated. 1.3 M of LiPF 6 dissolved in ethylene carbonate (EC), ethylmethyl carbonate (EMC) and dimethyl carbonate (DMC) of 3:3:4 volume ratio is used as original electrolyte for 18650 cylindrical cells with LiCoO 2 cathode and graphite anode. VC is then added to electrolyte. At the initial stage of the high temperature storage, higher open-circuit voltage (OCV) is maintained when increasing the VC concentration. As the storage time increases, OCV of higher VC concentration drops gradually, and then the gas evolution takes place abruptly. Gas analysis shows methane (CH 4) decreases with increase of the VC concentration due to formation of stable solid electrolyte interface (SEI) layer on the graphite. Since the residual VC after formation of the SEI layer decomposes on the cathode surface, carbon dioxide (CO 2) dramatically increases on the cathode with the VC concentration, leaving poly(VC) film at the anode surface, as suggested by XPS test results.

  11. 30 CFR 75.511 - Low-, medium-, or high-voltage distribution circuits and equipment; repair.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Low-, medium-, or high-voltage distribution... Electrical Equipment-General § 75.511 Low-, medium-, or high-voltage distribution circuits and equipment; repair. No electrical work shall be performed on low-, medium-, or high-voltage distribution circuits or...

  12. 30 CFR 75.705-1 - Work on high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines. 75.705-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.705-1 Work on high-voltage lines. (a) Section 75.705 specifically prohibits work on energized high-voltage lines underground;...

  13. 30 CFR 77.807-3 - Movement of equipment; minimum distance from high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... high-voltage lines. 77.807-3 Section 77.807-3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-3 Movement of equipment; minimum distance from high-voltage lines. When any part of any equipment operated on the surface of...

  14. 30 CFR 75.705-10 - Tying into energized high-voltage surface circuits.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tying into energized high-voltage surface....705-10 Tying into energized high-voltage surface circuits. If the work of forming an additional circuit by tying into an energized high-voltage surface line is performed from the ground, any...

  15. 21 CFR 892.1700 - Diagnostic x-ray high voltage generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic x-ray high voltage generator. 892.1700... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1700 Diagnostic x-ray high voltage generator. (a) Identification. A diagnostic x-ray high voltage generator is a device that is intended...

  16. 30 CFR 75.811 - High-voltage underground equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage underground equipment; grounding... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.811 High-voltage underground equipment; grounding. Frames, supporting structures...

  17. 30 CFR 77.704-10 - Tying into energized high-voltage surface circuits.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tying into energized high-voltage surface... AREAS OF UNDERGROUND COAL MINES Grounding § 77.704-10 Tying into energized high-voltage surface circuits. If the work of forming an additional circuit by tying into an energized high-voltage surface line...

  18. 30 CFR 75.800 - High-voltage circuits; circuit breakers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage circuits; circuit breakers. 75.800... § 75.800 High-voltage circuits; circuit breakers. High-voltage circuits entering the underground area of any coal mine shall be protected by suitable circuit breakers of adequate interrupting...

  19. Design and Simulation Test of an Open D-Dot Voltage Sensor

    Directory of Open Access Journals (Sweden)

    Yunjie Bai

    2015-09-01

    Full Text Available Nowadays, sensor development focuses on miniaturization and non-contact measurement. According to the D-dot principle, a D-dot voltage sensor with a new structure was designed based on the differential D-dot sensor with a symmetrical structure, called an asymmetric open D-dot voltage sensor. It is easier to install. The electric field distribution of the sensor was analyzed through Ansoft Maxwell and an open D-dot voltage sensor was designed. This open D-voltage sensor is characteristic of accessible insulating strength and small electric field distortion. The steady and transient performance test under 10 kV-voltage reported satisfying performances of the designed open D-dot voltage sensor. It conforms to requirements for a smart grid measuring sensor in intelligence, miniaturization and facilitation.

  20. Evaluation of Niobium as Candidate Electrode Material for DC High Voltage Photoelectron Guns

    Science.gov (United States)

    BastaniNejad, M.; Mohamed, Abdullah; Elmustafa, A. A.; Adderley, P.; Clark, J.; Covert, S.; Hansknecht, J.; Hernandez-Garcia, C.; Poelker, M.; Mammei, R.; hide

    2012-01-01

    The field emission characteristics of niobium electrodes were compared to those of stainless steel electrodes using a DC high voltage field emission test apparatus. A total of eight electrodes were evaluated: two 304 stainless steel electrodes polished to mirror-like finish with diamond grit and six niobium electrodes (two single-crystal, two large-grain, and two fine-grain) that were chemically polished using a buffered-chemical acid solution. Upon the first application of high voltage, the best large-grain and single-crystal niobium electrodes performed better than the best stainless steel electrodes, exhibiting less field emission at comparable voltage and field strength. In all cases, field emission from electrodes (stainless steel and/or niobium) could be significantly reduced and sometimes completely eliminated, by introducing krypton gas into the vacuum chamber while the electrode was biased at high voltage. Of all the electrodes tested, a large-grain niobium electrode performed the best, exhibiting no measurable field emission (< 10 pA) at 225 kV with 20 mm cathode/anode gap, corresponding to a field strength of 18:7 MV/m.

  1. Pollution Maintenance Techniques in Coastal High Voltage Installations

    Directory of Open Access Journals (Sweden)

    E. Pyrgioti

    2011-02-01

    Full Text Available Pollution of outdoor high voltage insulators is a common problem for utilities, with a considerable impact to power system reliability. In an effort to prevent possible flashovers due to pollution, many methods have been applied, aiming to improve the insulation performance, either by suppressing the formation of surface conductivity or by increasing the possible insulation level. In the case of substations, the selection of the appropriate technique is complex due to certain issues correlated to the nature of the installation. In this paper, several techniques usually implemented by utilities, are investigated based on the experienced gained in the case of Crete, a Greek island in southern Europe, where due to the coastal development of the power system, the majority of high voltage installations are exposed to intense marine pollution. The technique of coating insulators with Room Temperature Vulcanized Silicone Rubber (RTV SIR has proved rather efficient and therefore is presented extendedly. Correlation of the material behaviour with environmental conditions is discussed and results from long term monitoring, including environmental parameters and leakage current measurements, in a 150 kV Substation are presented. It is shown that RTV SIR coatings have remarkably suppressed surface activity and that porcelain insulators exhibit different activity period when coated.

  2. A high-voltage rechargeable magnesium-sodium hybrid battery

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yifei; An, Qinyou; Cheng, Yingwen; Liang, Yanliang; Ren, Yang; Sun, Cheng-Jun; Dong, Hui; Tang, Zhongjia; Li, Guosheng; Yao, Yan

    2017-04-01

    Growing global demand of safe and low-cost energy storage technology triggers strong interests in novel battery concepts beyond state-of-art Li-ion batteries. Here we report a high-voltage rechargeable Mg–Na hybrid battery featuring dendrite-free deposition of Mg anode and Na-intercalation cathode as a low-cost and safe alternative to Li-ion batteries for large-scale energy storage. A prototype device using a Na3V2(PO4)3 cathode, a Mg anode, and a Mg–Na dual salt electrolyte exhibits the highest voltage (2.60 V vs. Mg) and best rate performance (86% capacity retention at 10C rate) among reported hybrid batteries. Synchrotron radiation-based X-ray absorption near edge structure (XANES), atomic-pair distribution function (PDF), and high-resolution X-ray diffraction (HRXRD) studies reveal the chemical environment and structural change of Na3V2(PO4)3 cathode during the Na ion insertion/deinsertion process. XANES study shows a clear reversible shift of vanadium K-edge and HRXRD and PDF studies reveal a reversible two-phase transformation and V–O bond length change during cycling. The energy density of the hybrid cell could be further improved by developing electrolytes with a higher salt concentration and wider electrochemical window. This work represents a significant step forward for practical safe and low-cost hybrid batteries.

  3. Nickel-gallium arsenide high-voltage power Schottky diodes

    Science.gov (United States)

    Ashkinazi, G.; Hadas, Tz.; Meyler, B.; Nathan, M.; Zolotarevski, L.; Zolotarevski, O.

    1993-01-01

    A power GaAs Schottky diode (SD) with a chemically deposited Ni barrier was designed, fabricated and tested. The diode has a reverse breakdown voltage VBR of 140 V, forward voltage drop VF (at 50 A/cm 2) of 0.7 V at 23°C, 0.5 V at 150°C and 0.3 V at 250°C, and reverse leakage current densities jR (at -50 V) of 0.1 μA/cm 2 at 23°C and 1 mA/cm 2 at 150°C. Calculated forward and reverse I- V characteristics using a simple self-consistent computer model are in good agreement with measured values. Calculated characteristics of a silicon SD with identical structure parameters, using the same model, show much poorer VBR, VF and jR values. The theoretical maximum value of VBR is physically limited by the largest allowed VF. For a V Fof ⋍1.6 V, V BR.maxis ⋍200 V in Si and ⋍800 simple technology allows manufacturing of large area GaAs Schottky diodes with average currents up to V in GaAs SDs. Our relatively 100 A.

  4. Evolution of recrystallization textures in high voltage aluminum capacitor foils

    Institute of Scientific and Technical Information of China (English)

    刘楚明; 张新明; 周鸿章; 陈志永; 邓运来; 周卓平

    2001-01-01

    The evolution of recrystallization textures in high voltage aluminum capacitor foils which are produced with a high level of cold reduction was tracked by analysis of microstructure and crystallographic texture. The results show that the deformation textures are mainly composed of S-orientation, Cu-orientation and a little Bs-orientation. During the low temperature stages of final annealing, the iron precipitates first along the sub-grain boundaries, and the Fe concentration in the matrix becomes low. Then, the cube grains nucleate preferably into the sub-grains. At high temperature stages, the cube nuclei can grow preferably because of their 40°〈111〉 orientation relationship to the S orientation, the main component of the rolling texture. Finally, the cube texture is sharply strong and the R orientation is very weak in the foils.

  5. Class D audio amplifiers for high voltage capacitive transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis

    voltage capacitive transducers can be constructed with THD+N below 0.1 % and peak efficiency above 80 %. However the complexity of the amplifier combined with the current high cost of components, makes the technology of DEAP based loudspeaker unfeasible. Suggestions to future work in the pursuit...... of high volume, weight, and cost. High efficient class D amplifiers are now widely available offering power densities, that their linear counterparts can not match. Unlike the technology of audio amplifiers, the loudspeaker is still based on the traditional electrodynamic transducer invented by C.W. Rice....... Due to the similarities between the electrostatic loudspeaker and the DEAP transducer, the state-of-the-art has a special focus on amplifiers for electrostatic loudspeakers. Amplifiers for other type of capacitive transducers like piezoelectric ones are also considered. Finally the current state...

  6. Design of the all solid high-voltage power supply for a gyrotron body

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Yihua [School of Mathematics and Physics, University of South China, Hengyang, 421001 (China); Chen, Wenguang, E-mail: 430000485393@usc.edu.cn [School of Electrical Engineering, University of South China, Hengyang, 421001 (China); Hu, Bo [School of Electrical Engineering, University of South China, Hengyang, 421001 (China); Rao, Jun; Huang, Mei; Kang, Zihua; Feng, Kun [Southwestern Institute of Physics, Chengdu, 610041 (China); Huang, Jiaqi [School of Electrical Engineering, University of South China, Hengyang, 421001 (China)

    2017-04-15

    Highlights: • Completed design of all solid-state high-voltage power supply for gyrotron body on HL-2M ECRH. • Consist of 58 PSM modules and one BUCK module, controlled by DSP system. • Fabricated full voltage 35 kV, 200 mA BPS and tested in dummy load. • The BPS can operate in three modes: single pulse mode, multi-pulse modulation mode and the six-level preset mode. - Abstract: Gyrotron plays an important role in the research of electron cyclotron resonance heating (ECRH) on Tokomak. The high-frequency switched power supply technology and pulse step modulation (PSM) technology are used in the development of the all solid high-voltage body power supply (BPS) for 1 MW/105 GHz Gyrotron on ECRH system. Firstly, the basic structure of the BPS and its control system are introduced. Secondly, the software control algorithm of voltage stabilization and modulate method are developed. Finally, the design is verified by the experiments. The experimental results of the single pulse mode, the multi-pulse modulation mode and the six-level preset mode, are shown. The output voltage of the power supply can reach 35 kV and the current at about 200 mA, which are adjustable in the full range. The maximum modulation frequency can reach 1 kHz and the front edge of the pulse can be adjust from 0 to 3 ms and the accuracy of the output voltage is less than 100 V. The results show that the control method is feasible and can be applied to other high power microwave sources.

  7. Compact high voltage, high peak power, high frequency transformer for converter type modulator applications.

    Science.gov (United States)

    Reghu, T; Mandloi, V; Shrivastava, Purushottam

    2016-04-01

    The design and development of a compact high voltage, high peak power, high frequency transformer for a converter type modulator of klystron amplifiers is presented. The transformer has been designed to operate at a frequency of 20 kHz and at a flux swing of ±0.6 T. Iron (Fe) based nanocrystalline material has been selected as a core for the construction of the transformer. The transformer employs a specially designed solid Teflon bobbin having 120 kV insulation for winding the high voltage secondary windings. The flux swing of the core has been experimentally found by plotting the hysteresis loop at actual operating conditions. Based on the design, a prototype transformer has been built which is per se a unique combination of high voltage, high frequency, and peak power specifications. The transformer was able to provide 58 kV (pk-pk) at the secondary with a peak power handling capability of 700 kVA. The transformation ratio was 1:17. The performance of the transformer is also presented and discussed.

  8. High Efficiency Interleaved Active Clamped Dc-Dc Converter with Fuel Cell for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Sona P

    2014-02-01

    Full Text Available A high efficiency interleaved ZVS active clamped current fed dc-dc converter is proposed in this paper specially used for fuel cell applications. As the fuel cell output is very low we are in need of a step up dc-dc converter. Here a current fed dc-dc converter is used. Two current fed dc-dc converters are interleaved by connecting their inputs in parallel and outputs in series. With this proposed methodology input current ripples in the fuel cell stacks can be reduced and a regulated output voltage ripples can be obtained. The active clamping circuit used in this model absorbs the turn off voltage spikes hence low voltage devices with low on state resistance can be used.Voltage doubler circuits will give double the output voltage than normal with smaller transformer turns ratio and flexibility. The proposed method is simulated in MATLAB for verifying the accuracy of the proposed design.

  9. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Marzocchi, Badder

    2017-01-01

    The CMS Electromagnetic Calorimeter is made of scintillating lead tungstate crystals, using avalanche photodiodes (APD) as photo-detectors in the barrel part. The high voltage system, consisting of 1224 channels, biases groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  10. Development of high voltage power supply for the KSTAR 170 GHz ECH and CD system

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, J.H., E-mail: jhjeong@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Bae, Y.S.; Joung, M.; Kim, H.J.; Park, S.I.; Han, W.S.; Kim, J.S.; Yang, H.L.; Kwak, J.G. [National Fusion Research Institute, Daejeon (Korea, Republic of); Sakamoto, K.; Kajiwara, K.; Oda, Y.; Hayashi, K. [Japan Atomic Energy Agency, Naka (Japan)

    2013-06-15

    switch is also introduced between the body and collector for high frequency RF modulation. This paper describes the key features of the high voltage power supply system of the KSTAR 170 GHz gyrotron as well as the test results of the power supply.

  11. Propylene based systems for high voltage cable insulation applications

    Energy Technology Data Exchange (ETDEWEB)

    Hosier, I L; Vaughan, A S; Swingler, S G [ECS, University of Southampton, Highfield, Southampton, SO17 1BJ (United Kingdom); Cozzarini, L, E-mail: ILH@ecs.soton.ac.u [DMRN, University of Trieste, Via Valerio 6A, 34127 Trieste (Italy)

    2009-08-01

    Crosslinked polyethylene (XLPE) remains the material of choice for extruded high voltage cables, possessing excellent thermo-mechanical and electrical properties. However, it is not easily recyclable posing questions as to its long term sustainability. Whilst both polyethylene and polypropylene are widely recycled and provide excellent dielectric properties, polypropylene has significantly better mechanical integrity at high temperatures than polyethylene. However, while isotactic polypropylene is too stiff at room temperature for incorporation into a cable system, previous studies by the authors have indicated that this limitation can be overcome by using a propylene-ethylene copolymer. Whilst these previous studies considered unrelated systems, the current study aims to quantify the usefulness of a series of related random propylene-ethylene co-polymers and assesses their potential for replacing XLPE.

  12. High-voltage atmospheric breakdown across intervening rutile dielectrics.

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, Kenneth Martin; Simpson, Sean; Coats, Rebecca Sue; Jorgenson, Roy Eberhardt; Hjalmarson, Harold Paul; Pasik, Michael Francis

    2013-09-01

    This report documents work conducted in FY13 on electrical discharge experiments performed to develop predictive computational models of the fundamental processes of surface breakdown in the vicinity of high-permittivity material interfaces. Further, experiments were conducted to determine if free carrier electrons could be excited into the conduction band thus lowering the effective breakdown voltage when UV photons (4.66 eV) from a high energy pulsed laser were incident on the rutile sample. This report documents the numerical approach, the experimental setup, and summarizes the data and simulations. Lastly, it describes the path forward and challenges that must be overcome in order to improve future experiments for characterizing the breakdown behavior for rutile.

  13. High Voltage Dielectrophoretic and Magnetophoretic Hybrid Integrated Circuit / Microfluidic Chip

    Science.gov (United States)

    Issadore, David; Franke, Thomas; Brown, Keith A.; Hunt, Thomas P.; Westervelt, Robert M.

    2010-01-01

    A hybrid integrated circuit (IC) / microfluidic chip is presented that independently and simultaneously traps and moves microscopic objects suspended in fluid using both electric and magnetic fields. This hybrid chip controls the location of dielectric objects, such as living cells and drops of fluid, on a 60 × 61 array of pixels that are 30 × 38 μm2 in size, each of which can be individually addressed with a 50 V peak-to-peak, DC to 10 MHz radio frequency voltage. These high voltage pixels produce electric fields above the chip’s surface with a magnitude , resulting in strong dielectrophoresis (DEP) forces . Underneath the array of DEP pixels there is a magnetic matrix that consists of two perpendicular sets of 60 metal wires running across the chip. Each wire can be sourced with 120 mA to trap and move magnetically susceptible objects using magnetophoresis (MP). The DEP pixel array and magnetic matrix can be used simultaneously to apply forces to microscopic objects, such as living cells or lipid vesicles, that are tagged with magnetic nanoparticles. The capabilities of the hybrid IC / microfluidic chip demonstrated in this paper provide important building blocks for a platform for biological and chemical applications. PMID:20625468

  14. An Internal ALD-Based High Voltage Divider and Signal Circuit for MCP-based Photodetectors

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Bernhard W.; Elagin, Andrey; Elam, Jeffrey W.; Frisch, Henry J.; Genat, Jean-Francois; Gregar, Joseph S.; Mane, Anil U.; Minot, Michael J.; Northrup, Richard; Obaid, Razib; Oberla, Eric; Alexander, Vostrikov; Wetstein, Matthew

    2015-04-21

    We describe a pin-less design for the high voltage (HV) resistive divider of the all-glass LAPPD (TM) 8 in,square thin photodetector module. The divider, which distributes high voltage applied to the photocathode to the two micro-channel plates (MCPs) that constitute the amplification stage, is comprised of the two MCPs and three glass mechanical spacers, each of which is coated with a resistive layer using atomic layer deposition (ALD). The three glass grid spacers and the two MCPs form a continuous resistive path between cathode and anode, with the voltages across the MCPs and the spacers determined by the resistance of each. High voltage is applied on an external tab on the top glass window that connects to the photocathode through the metal seal. The DC ground is supplied by microstrips on the bottom glass plate that form the high-bandwidth anode. The microstrips exit the package through the glass-frit seal of the anode base-plate and the package sidewall. The divider is thus completely internal, with no HV pins penetrating the low-profile flat glass package. Measurements of the performance of the divider are presented for the 8 in.-square MCP and spacer package in a custom test fixture and for an assembled externally pumped LAPPD (TM) prototype with an aluminum photocathode. (C) 2015 Elsevier B.V. All rights reserved.

  15. 250 kV 6 mA compact Cockcroft-Walton high-voltage power supply.

    Science.gov (United States)

    Ma, Zhan-Wen; Su, Xiao-Dong; Lu, Xiao-Long; Wei, Zhen; Wang, Jun-Run; Huang, Zhi-Wu; Miao, Tian-You; Su, Tong-Ling; Yao, Ze-En

    2016-08-01

    A compact power supply system for a compact neutron generator has been developed. A 4-stage symmetrical Cockcroft-Walton circuit is adopted to produce 250 kV direct current high-voltage. A 2-stage 280 kV isolation transformer system is used to drive the ion source power supply. For a compact structure, safety, and reliability during the operation, the Cockcroft-Walton circuit and the isolation transformer system are enclosed in an epoxy vessel containing the transformer oil whose size is about ∅350 mm × 766 mm. Test results indicate that the maximum output voltage of the power supply is 282 kV, and the stability of the output voltage is better than 0.63% when the high voltage power supply is operated at 250 kV, 6.9 mA with the input voltage varying ±10%.

  16. 250 kV 6 mA compact Cockcroft-Walton high-voltage power supply

    Science.gov (United States)

    Ma, Zhan-Wen; Su, Xiao-Dong; Lu, Xiao-Long; Wei, Zhen; Wang, Jun-Run; Huang, Zhi-Wu; Miao, Tian-You; Su, Tong-Ling; Yao, Ze-En

    2016-08-01

    A compact power supply system for a compact neutron generator has been developed. A 4-stage symmetrical Cockcroft-Walton circuit is adopted to produce 250 kV direct current high-voltage. A 2-stage 280 kV isolation transformer system is used to drive the ion source power supply. For a compact structure, safety, and reliability during the operation, the Cockcroft-Walton circuit and the isolation transformer system are enclosed in an epoxy vessel containing the transformer oil whose size is about ∅350 mm × 766 mm. Test results indicate that the maximum output voltage of the power supply is 282 kV, and the stability of the output voltage is better than 0.63% when the high voltage power supply is operated at 250 kV, 6.9 mA with the input voltage varying ±10%.

  17. Human-rated Safety Certification of a High Voltage Robonaut Lithium-ion Battery

    Science.gov (United States)

    Jeevarajan, Judith; Yayathi, S.; Johnson, M.; Waligora, T.; Verdeyen, W.

    2013-01-01

    NASA's rigorous certification process is being followed for the R2 high voltage battery program for use of R2 on International Space Station (ISS). Rigorous development testing at appropriate levels to credible off-nominal conditions and review of test data led to design improvements for safety at the virtual cell, cartridge and battery levels. Tests were carried out at all levels to confirm that both hardware and software controls work. Stringent flight acceptance testing of the flight battery will be completed before launch for mission use on ISS.

  18. Automatic Functional Step-up System in High-Voltage Installation

    Institute of Scientific and Technical Information of China (English)

    陈方泉; 严一白; 宋进; 林财兴

    2004-01-01

    This article describes automatic functional step-up systems in high-voltage installation, with emphases on functional process of step-up and step-down, two-circuit control and elimination of tip burr voltage.

  19. Unique Power Dense, Configurable, Robust, High-Voltage Power Supplies Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Princeton Power will develop and deliver three small, lightweight 50 W high-voltage power supplies that have a configurable output voltage range from 500 to 50 kVDC....

  20. Battery powered high output voltage bidirectional flyback converter for cylindrical DEAP actuator

    DEFF Research Database (Denmark)

    Huang, Lina; Thummala, Prasanth; Zhang, Zhe;

    2012-01-01

    DEAP (Dielectric Electro Active Polymer) actuator is essentially a capacitive load and can be applied in various actuation occasions. However, high voltage is needed to actuate it. In this paper, a high voltage bidirectional flyback converter with low input voltage is presented. The fundamental....... The design parameters for flyback transformer and snubber circuits are illustrated. Moreover, the experimental waveforms are provided....

  1. 30 CFR 57.12071 - Movement or operation of equipment near high-voltage powerlines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Movement or operation of equipment near high-voltage powerlines. 57.12071 Section 57.12071 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION...-voltage powerlines. When equipment must be moved or operated near energized high-voltage powerlines...

  2. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Science.gov (United States)

    2010-07-01

    ...-voltage power lines. 56.12071 Section 56.12071 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... NONMETAL MINES Electricity § 56.12071 Movement or operation of equipment near high-voltage power lines. When equipment must be moved or operated near energized high-voltage powerlines (other than...

  3. 30 CFR 77.807-2 - Booms and masts; minimum distance from high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ...-voltage lines. 77.807-2 Section 77.807-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-2 Booms and masts; minimum distance from high-voltage lines. The booms and masts of equipment operated on the surface of...

  4. Biological and Agricultural Studies on Application of Discharge Plasma and Electromagnetic Fields 4. Destruction of Weeds by High Voltage Discharge

    Science.gov (United States)

    Mizuno, Akira

    In an attempt to replace chemicals for weed control, high voltage spark discharge has been applied. With the application of high voltage, discharge takes place, and current flows through the stem and root. Microscopic observation indicates that cells are damaged. The electrical resistance of the damage plant’s stems and roots decreased significantly. Several different types of apparatus were constructed, and field test results show the effectiveness of electrical discharge for weed control.

  5. Understanding and Improving High Voltage Vacuum Insulators for Microsecond Pulses

    Energy Technology Data Exchange (ETDEWEB)

    Javedani, J B; Goerz, D A; Houck, T L; Lauer, E J; Speer, R D; Tully, L K; Vogtlin, G E; White, A D

    2007-03-05

    High voltage insulation is one of the main areas of pulsed power research and development, and dielectric breakdown is usually the limiting factor in attaining the highest possible performance in pulsed power devices. For many applications the delivery of pulsed power into a vacuum region is the most critical aspect of operation. The surface of an insulator exposed to vacuum can fail electrically at an applied field more than an order or magnitude below the bulk dielectric strength of the insulator. This mode of breakdown, called surface flashover, imposes serious limitations on the power flow into a vacuum region. This is especially troublesome for applications where high voltage conditioning of the insulator and electrodes is not practical and for applications where relatively long pulses, on the order of several microseconds, are required. The goal of this project is to establish a sound fundamental understanding of the mechanisms that lead to surface flashover, and then evaluate the most promising techniques to improve vacuum insulators and enable high voltage operation at stress levels near the intrinsic bulk breakdown limits of the material. The approach we proposed and followed was to develop this understanding through a combination of theoretical and computation methods coupled with experiments to validate and quantify expected behaviors. In this report we summarize our modeling and simulation efforts, theoretical studies, and experimental investigations. The computational work began by exploring the limits of commercially available codes and demonstrating methods to examine field enhancements and defect mechanisms at microscopic levels. Plasma simulations with particle codes used in conjunction with circuit models of the experimental apparatus enabled comparisons with experimental measurements. The large scale plasma (LSP) particle-in-cell (PIC) code was run on multiprocessor platforms and used to simulate expanding plasma conditions in vacuum gap regions

  6. Simulation Model solves exact the Enigma named Generating high Voltages and high Frequencies by Tesla Coil

    Directory of Open Access Journals (Sweden)

    Simo Janjanin

    2016-11-01

    Full Text Available Simulation model of Tesla coil has been successfully completed, and has been verified the procedure and functioning. The literature and documentation for the model were taken from the rich sources, especially the copies of Tesla patents. The oscillating system‟s electrical scheme consists of the voltage supply 220/50 Hz, Fe transformer, capacitor and belonging chosen electrical components, the air gap in the primary Tesla coil (air transformer and spark gap in the exit of the coil. The investigation of the oscillating process Tesla coil‟s system using the simulation model in MATLAB & SIMULINK have given the exact solution the enigma named the generating high voltage and high frequency the Tesla‟s coil. The inductance voltage from the spark current in the primary (coil with its high voltage impulse excites the oscillating series circuit Ce-L3-R3 on the secondary of the air transformer to its own damped oscillations

  7. Reliability of High-Voltage Tantalum Capacitors. Parts 3 and 4)

    Science.gov (United States)

    Teverovsky, Alexander

    2010-01-01

    Weibull grading test is a powerful technique that allows selection and reliability rating of solid tantalum capacitors for military and space applications. However, inaccuracies in the existing method and non-adequate acceleration factors can result in significant, up to three orders of magnitude, errors in the calculated failure rate of capacitors. This paper analyzes deficiencies of the existing technique and recommends more accurate method of calculations. A physical model presenting failures of tantalum capacitors as time-dependent-dielectric-breakdown is used to determine voltage and temperature acceleration factors and select adequate Weibull grading test conditions. This model is verified by highly accelerated life testing (HALT) at different temperature and voltage conditions for three types of solid chip tantalum capacitors. It is shown that parameters of the model and acceleration factors can be calculated using a general log-linear relationship for the characteristic life with two stress levels.

  8. Hybrid-PIC Modeling of a High-Voltage, High-Specific-Impulse Hall Thruster

    Science.gov (United States)

    Smith, Brandon D.; Boyd, Iain D.; Kamhawi, Hani; Huang, Wensheng

    2013-01-01

    The primary life-limiting mechanism of Hall thrusters is the sputter erosion of the discharge channel walls by high-energy propellant ions. Because of the difficulty involved in characterizing this erosion experimentally, many past efforts have focused on numerical modeling to predict erosion rates and thruster lifespan, but those analyses were limited to Hall thrusters operating in the 200-400V discharge voltage range. Thrusters operating at higher discharge voltages (V(sub d) >= 500 V) present an erosion environment that may differ greatly from that of the lower-voltage thrusters modeled in the past. In this work, HPHall, a well-established hybrid-PIC code, is used to simulate NASA's High-Voltage Hall Accelerator (HiVHAc) at discharge voltages of 300, 400, and 500V as a first step towards modeling the discharge channel erosion. It is found that the model accurately predicts the thruster performance at all operating conditions to within 6%. The model predicts a normalized plasma potential profile that is consistent between all three operating points, with the acceleration zone appearing in the same approximate location. The expected trend of increasing electron temperature with increasing discharge voltage is observed. An analysis of the discharge current oscillations shows that the model predicts oscillations that are much greater in amplitude than those measured experimentally at all operating points, suggesting that the differences in oscillation amplitude are not strongly associated with discharge voltage.

  9. High Voltage Performance of the Beam Screen of the LHC Injection Kicker Magnets

    CERN Document Server

    Barnes, MJ; Bregliozzi, G; Calatroni, S; Costa Pinto, P; Day, H; Ducimetière, L; Kramer, T; Namora, V; Mertens, V; Taborelli, M

    2014-01-01

    The LHC injection kicker magnets include beam screens to shield the ferrite yokes against wakefields resulting from the high intensity beam. The screening is provided by conductors lodged in the inner wall of a ceramic support tube. The design of the beam screen has been upgraded to overcome limitations and permit LHC operation with increasingly higher bunch intensity and short bunch lengths: the new design also significantly reduces the electric field associated with the screen conductors, decreasing the probability of electrical breakdown. The high voltage conditioning process for the upgraded kicker magnets is presented and discussed. In addition a test setup has been utilized to study flashover, on the inner wall of the ceramic tube, as a function of both applied voltage and vacuum pressure: results from the test setup are presented.

  10. Research on The Mechanical State Parameter Extraction Method of High Voltage Circuit Breakers

    Directory of Open Access Journals (Sweden)

    Yang Tianxu

    2013-05-01

    Full Text Available High voltage circuit breakers play an important role in the power system. So it is necessary to implement the state detection of breakers in order to ensure stable and reliable running of the grid. The purpose of state detection is to provide reliable basis of maintenance by extracting mechanical state parameters accurately. This paper mainly focuses on the coil current signal feature extraction algorithm. To settle the problem of too much noise mixed with the current signal and signal distortion, the discrete wavelet transform algorithm is used to extract the coil current signal parameters. This paper also designs the FIR filter to extract stroke and speed parameters from travel-time waveform. The experiments show that the difference between the theoretical results and test results processed by the method in this paper is very small and the test results are able to accurately reflect operation states and mechanical features of high voltage circuit breakers.

  11. Evaluation of Epoxy Nanocomposites for High Voltage Insulation

    Science.gov (United States)

    Iyer, Ganpathy

    Polymeric materials containing nanometer (nm) size particles are being introduced to provide compact shapes for low and medium voltage insulation equipment. The nanocomposites may provide superior electrical performance when compared with those available currently, such as lower dielectric losses and increased dielectric strength, tracking and erosion resistance, and surface hydrophobicity. All of the above mentioned benefits can be achieved at a lower filler concentration (resistance tests were conducted over 500 hours to monitor degradation in the samples due to corona. These tests revealed improvements in partial discharge endurance of nanocomposite samples. These improvements could not be adequately explained using a macroscopic quantity such as thermal conductivity. Thermo gravimetric analysis (TGA) showed higher weight loss initiation temperatures for nanofilled samples which is in agreement with the corona resistance experimental results. Theoretical models have also been developed in this work to complement the results of the corona resistance experiment and the TGA analysis. Degradation model was developed to map the erosion path using Dijkstra's shortest path algorithm. A thermal model was developed to calculate the localized temperature distribution in the micro and nano-filled samples using the PDE toolbox in MATLAB. Both the models highlight the fact that improvement in nanocomposites is not limited to the filler concentrations that were tested experimentally.

  12. High Voltage Installation of PS Linac 1 Preinjector

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The high-voltage installation of the linac 1 preinjector in its house-sized Faraday cage. Originally driven by a 520 kV Cockcroft-Walton generator, at the time of this picture the HV came from a 520 kV SAMES generator. The column in the front carries a capacitor. The cubicle in the right background is the electronics platform (see 7403120). The round structure at left houses the ion source, from where the protons (and sometimes other ions), electrostatically accelerated to 520 keV, enter the Alvarez structure of linac 1, to be accelerated to 50 MeV. Jean-Luc Vallet is busy with servicing the installation. See also 7403064X, 7403066X.

  13. Control Strategy for Cascaded Medium - High Voltage STATCOM

    Directory of Open Access Journals (Sweden)

    Libing Chen

    2013-12-01

    Full Text Available Control strategy is researched for cascaded medium high static synchronous compensator to provide synthetic compensation ability of reactive power, harmonics and asymmetric currents. Basing on selective harmonic compensation strategy, a reference current detection method utilizing the combination of synchronous reference frame transformation and discrete Fourier transformation is proposed. The tracking control of instruction current is implemented by multi-carrier pulse width modulation (PWM. In allusion to the multi-carrier PWM, the capacitor voltage balancing control at the dc side is realized by a type of software based on the energy balance principle of the inverter bridge. The proposed control strategy is convenient for engineering implementation given its low calculation burden and simplicity. The effectiveness of the proposed control strategy is proven by both simulation and experimental results.

  14. High voltage direct current modelling in optimal power flows

    Energy Technology Data Exchange (ETDEWEB)

    Ambriz-Perez, H. [Comision Federal de Electricidad, Mexico, Unidad de Ingenieria Especializada, Rio Rodano No. 14 - Piso 10, Sala 1002, Col. Cuauhtemoc, C.P. 06598, Mexico, D.F. (Mexico); Acha, E. [Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow G128LT, Scotland (United Kingdom); Fuerte-Esquivel, C.R. [Faculty of Electrical Engineering, Universidad Michoacana de San Nicolas de Hidalgo, Morelia 58030, Michoacan (Mexico)

    2008-03-15

    Two-terminal high voltage direct current (HVDC) transmission links are in operation throughout the world. They are key elements in electrical power networks; their representation is oversimplified or ignored in most power system studies. This is particularly the case in Optima Power Flow (OPF) studies. Hence, an OPF program has been extended to incorporate HVDC links, taking due account of overlapping and power transfer control characteristics. This is a new development in Newton Optimal Power Flows, where the converter equations are included directly in the matrix W. The method is indeed a unified one since the solution vector is extended to accommodate the DC variables. The HVDC link model correctly takes into account the relevant DC limit variables. The impact of HVDC links on OPF studies is illustrated by numeric examples, which includes a 5-node system, the AEP 14-node and a 166-node system. (author)

  15. High-voltage, low-inductance gas switch

    Science.gov (United States)

    Gruner, Frederick R.; Stygar, William A.

    2016-03-22

    A low-inductance, air-insulated gas switch uses a de-enhanced annular trigger ring disposed between two opposing high voltage electrodes. The switch is DC chargeable to 200 kilovolts or more, triggerable, has low jitter (5 ns or less), has pre-fire and no-fire rates of no more than one in 10,000 shots, and has a lifetime of greater than 100,000 shots. Importantly, the switch also has a low inductance (less than 60 nH) and the ability to conduct currents with less than 100 ns rise times. The switch can be used with linear transformer drives or other pulsed-power systems.

  16. Investigation into the High Voltage Shutdown of the Oxygen Generator System in the International Space Station

    Science.gov (United States)

    Carpenter, Joyce E.; Gentry, Gregory J.; Diderich, Greg S.; Roy, Robert J.; Golden, John L.; VanKeuren, Steve; Steele, John W.; Rector, Tony J.; Varsik, Jerome D.; Montefusco, Daniel J.; Wilson, Mark E.; Worthy, Erica S.

    2012-01-01

    The Oxygen Generation System (OGS) Hydrogen Dome Assembly Orbital Replacement Unit (ORU) serial number 00001 suffered a cell stack high-voltage shutdown on July 5, 2010. The Hydrogen Dome Assembly ORU was removed and replaced with the on-board spare ORU serial number 00002 to maintain OGS operation. The Hydrogen Dome Assembly ORU was returned from ISS on STS-133/ULF-5 in March 2011 with test, teardown and evaluation (TT&E) and failure analysis to follow.

  17. Plasma Interaction with International Space Station High Voltage Solar Arrays

    Science.gov (United States)

    Heard, John W.

    2002-01-01

    The International Space Station (ISS) is presently being assembled in low-earth orbit (LEO) operating high voltage solar arrays (-160 V max, -140 V typical with respect to the ambient atmosphere). At the station's present altitude, there exists substantial ambient plasma that can interact with the solar arrays. The biasing of an object to an electric potential immersed in plasma creates a plasma "sheath" or non-equilibrium plasma around the object to mask out the electric fields. A positively biased object can collect electrons from the plasma sheath and the sheath will draw a current from the surrounding plasma. This parasitic current can enter the solar cells and effectively "short out" the potential across the cells, reducing the power that can be generated by the panels. Predictions of collected current based on previous high voltage experiments (SAMPIE (Solar Array Module Plasma Interactions Experiment), PASP+ (Photovoltaic Array Space Power) were on the order of amperes of current. However, present measurements of parasitic current are on the order of several milliamperes, and the current collection mainly occurs during an "eclipse exit" event, i.e., when the space station comes out of darkness. This collection also has a time scale, t approx. 1000 s, that is much slower than any known plasma interaction time scales. The reason for the discrepancy between predictions and present electron collection is not understood and is under investigation by the PCU (Plasma Contactor Unit) "Tiger" team. This paper will examine the potential structure within and around the solar arrays, and the possible causes and reasons for the electron collection of the array.

  18. Architecture for a High-to-Medium-Voltage Power Converter

    Science.gov (United States)

    Vorpenian, Vatche

    2008-01-01

    A power converter now undergoing development is required to operate at a DC input potential ranging between 5.5 and 10 kV and a DC output potential of 400 V at a current up to 25 A. This power converter is also required to be sufficiently compact and reliable to fit and operate within the confines of a high-pressure case to be lowered to several miles (approx.5 km) below the surface of the ocean. The architecture chosen to satisfy these requirements calls for a series/ parallel arrangement of 48 high-frequency, pulse-width-modulation (PWM), transformer-isolation DC-to-DC power converter blocks. The input sides of the converter blocks would be connected in series so that the input potential would be divided among them, each of them being exposed to an input potential of no more than 10 kV/48 . 210 V. The series connection of inputs would also enforce a requirement that all the converter blocks operate at the same input current. The outputs of the converter blocks would be connected in a matrix comprising 6 parallel legs, each leg being a cascade of eight outputs wired in series (see figure). All the converter blocks would be identical within the tolerances of the values of their components. A single voltage feedback loop would regulate the output potential. All the converter blocks would be driven by the same PWM waveform generated by this feedback loop. The power transformer of each converter block would have a unity turns ratio and would be capable of withstanding as much as 10 kVDC between its primary and secondary windings. (Although, in general, the turns ratio could be different from unity, the simplest construction for minimizing leakage and maximizing breakdown voltage is attained at a turns ratio of unity.)

  19. High performance AC–DC control power supply for low voltage ride through inverters

    Indian Academy of Sciences (India)

    K Saichand; Akshay Kumrawat; Vinod John

    2016-02-01

    This paper presents a control power supply (CPS) design which is used to feed power to the subsystems of a power converter. The CPS design presented here maintains a constant 24Vdc output even over a wide (90Vrms to 270Vrms ) ac voltage variation at its input for a High Power Converter (HPC). The circuit design and closed loop control design of such a CPS are presented. During starting, the power supply to the control circuitry of the CPS in turn is obtained using a separate start-up power supply. The various design issues and details of the on-board power supply and start-up power circuit to ensure the reliable start-up and shut down of the CPS are analyzed. The CPS was tested for wide input voltage range (vin) and the performance validates the design. The CPS has also been tested for an input side voltage sag and its performance allows the HPC to meet the low voltage ride-through requirements.

  20. Test of the Tandem transmission at low terminal voltages

    Energy Technology Data Exchange (ETDEWEB)

    Rehm, K.E.; Blumenthal, D.; Gehring, J. [and others

    1995-08-01

    For a planned experiment with {sup 18}F beams at energies below 1 MeV/u the transmission of the Tandem-Linac system was investigated. The energies required in the experiment are typically around 600 keV/u, which for the most abundant charge states for F(4{sup +}) corresponds to terminal voltages between 2-3 MV. We studied the transmission from the source to the tandem accelerator and to the spectrograph in area II with {sup 18}O and {sup 19}F beams using two different approaches. In the first method only the tandem accelerator was used producing a 14-MeV DC {sup 18}O beam. In the second method a pulsed beam was accelerated to 33 MeV with the tandem accelerator followed by deceleration to 14 MeV with the first 9 resonators of ATLAS. The total transmission from ion source to target was in both cases about 10%. Because of the smaller complexity we used the first method for the {sup 18}F experiment. In future runs we are planning to use the electrostatic lens in the terminal of the tandem to improve the overall transmission.

  1. High voltage and high specific capacity dual intercalating electrode Li-ion batteries

    Science.gov (United States)

    West, William C. (Inventor); Blanco, Mario (Inventor)

    2010-01-01

    The present invention provides high capacity and high voltage Li-ion batteries that have a carbonaceous cathode and a nonaqueous electrolyte solution comprising LiF salt and an anion receptor that binds the fluoride ion. The batteries can comprise dual intercalating electrode Li ion batteries. Methods of the present invention use a cathode and electrode pair, wherein each of the electrodes reversibly intercalate ions provided by a LiF salt to make a high voltage and high specific capacity dual intercalating electrode Li-ion battery. The present methods and systems provide high-capacity batteries particularly useful in powering devices where minimizing battery mass is important.

  2. Atmospheric pressure microplasmas in ZnO nanoforests under high voltage stress

    Directory of Open Access Journals (Sweden)

    Nafisa Noor

    2015-09-01

    Full Text Available Atmospheric pressure ZnO microplasmas have been generated by high amplitude single pulses and DC voltages applied using micrometer-separated probes on ZnO nanoforests. The high voltage stress triggers plasma breakdown and breakdown in the surrounding air followed by sublimation of ZnO resulting in strong blue and white light emission with sharp spectral lines and non-linear current-voltage characteristics. The nanoforests are made of ZnO nanorods (NRs grown on fluorine doped tin oxide (FTO glass, poly-crystalline silicon and bulk p-type silicon substrates. The characteristics of the microplasmas depend strongly on the substrate and voltage parameters. Plasmas can be obtained with pulse durations as short as ∼1 μs for FTO glass substrate and ∼100 ms for the silicon substrates. Besides enabling plasma generation with shorter pulses, NRs on FTO glass substrate also lead to better tunability of the operating gas temperature. Hot and cold ZnO microplasmas have been observed with these NRs on FTO glass substrate. Sputtering of nanomaterials during plasma generation in the regions surrounding the test area has also been noticed and result in interesting ZnO nanostructures (‘nano-flowers’ and ‘nano-cauliflowers’. A practical way of generating atmospheric pressure ZnO microplasmas may lead to various lighting, biomedical and material processing applications.

  3. First high-voltage measurements using Ca{sup +} ions at the ALIVE experiment

    Energy Technology Data Exchange (ETDEWEB)

    König, K., E-mail: kkoenig@ikp.tu-darmstadt.de [Technische Universität Darmstadt, Institut für Kernphysik (Germany); Geppert, Ch. [Universität Mainz, Institut für Kernchemie (Germany); Krämer, J.; Maaß, B. [Technische Universität Darmstadt, Institut für Kernphysik (Germany); Otten, E. W. [Universität Mainz, Institut für Physik (Germany); Ratajczyk, T.; Nörtershäuser, W. [Technische Universität Darmstadt, Institut für Kernphysik (Germany)

    2017-11-15

    Many physics experiments depend on accurate high-voltage measurements to determine for example the exact retardation potential of an electron spectrometer as in the KATRIN experiment or the acceleration voltage of the ions at ISOL facilities. Until now only precision high-voltage dividers can be used to measure voltages up to 65 kV with an accuracy of 1 ppm. However, these dividers need frequent calibration and cross-checking and the direct traceability is not given. In this article we will describe the status of an experiment which aims to measure high voltages using collinear laser spectroscopy and which has the potential to provide a high-voltage standard and hence, a calibration source for precision high-voltage dividers on the 1 ppm level.

  4. Evaluation of high temperature dielectric films for high voltage power electronic applications

    Science.gov (United States)

    Suthar, J. L.; Laghari, J. R.

    1992-01-01

    Three high temperature films, polyimide, Teflon perfluoroalkoxy and poly-P-xylene, were evaluated for possible use in high voltage power electronic applications, such as in high energy density capacitors, cables and microelectronic circuits. The dielectric properties, including permittivity and dielectric loss, were obtained in the frequency range of 50 Hz to 100 kHz at temperatures up to 200 C. The dielectric strengths at 60 Hz were determined as a function of temperature to 250 C. Confocal laser microscopy was performed to diagnose for voids and microimperfections within the film structure. The results obtained indicate that all films evaluated are capable of maintaining their high voltage properties, with minimal degradation, at temperatures up to 200 C. However, above 200 C, they lose some of their electrical properties. These films may therefore become viable candidates for high voltage power electronic applications at high temperatures.

  5. High-Voltage-Input Level Translator Using Standard CMOS

    Science.gov (United States)

    Yager, Jeremy A.; Mojarradi, Mohammad M.; Vo, Tuan A.; Blalock, Benjamin J.

    2011-01-01

    proposed integrated circuit would translate (1) a pair of input signals having a low differential potential and a possibly high common-mode potential into (2) a pair of output signals having the same low differential potential and a low common-mode potential. As used here, "low" and "high" refer to potentials that are, respectively, below or above the nominal supply potential (3.3 V) at which standard complementary metal oxide/semiconductor (CMOS) integrated circuits are designed to operate. The input common-mode potential could lie between 0 and 10 V; the output common-mode potential would be 2 V. This translation would make it possible to process the pair of signals by use of standard 3.3-V CMOS analog and/or mixed-signal (analog and digital) circuitry on the same integrated-circuit chip. A schematic of the circuit is shown in the figure. Standard 3.3-V CMOS circuitry cannot withstand input potentials greater than about 4 V. However, there are many applications that involve low-differential-potential, high-common-mode-potential input signal pairs and in which standard 3.3-V CMOS circuitry, which is relatively inexpensive, would be the most appropriate circuitry for performing other functions on the integrated-circuit chip that handles the high-potential input signals. Thus, there is a need to combine high-voltage input circuitry with standard low-voltage CMOS circuitry on the same integrated-circuit chip. The proposed circuit would satisfy this need. In the proposed circuit, the input signals would be coupled into both a level-shifting pair and a common-mode-sensing pair of CMOS transistors. The output of the level-shifting pair would be fed as input to a differential pair of transistors. The resulting differential current output would pass through six standoff transistors to be mirrored into an output branch by four heterojunction bipolar transistors. The mirrored differential current would be converted back to potential by a pair of diode-connected transistors

  6. Optical fiber imaging for high speed plasma motion diagnostics: applied to low voltage circuit breakers.

    Science.gov (United States)

    McBride, J W; Balestrero, A; Ghezzi, L; Tribulato, G; Cross, K J

    2010-05-01

    An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs. An array of optical fibers allows the formation of low spatial resolution images, with a maximum capture rate of 1 x 10(6) images per second (1 MHz), with 8 bit intensity resolution. Novel software techniques are reported to allow imaging of the arc; and to measure arc trajectories. Results are presented on high current (2 kA) discharge events in a model test fixture and on the application to a commercial low voltage circuit breaker.

  7. DC buffering and floating current for a high voltage IMB application

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, J. L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-08-01

    An interface technique for the latest generation of the Impedance Measurement Box (IMB) has been conceived to enable measurement of impedance spectra for battery modules up to 300V. A 300V capable or higher IMB is an enabling technology for in-situ diagnostics within electric vehicle charging stations or battery back-ups within power distribution sub-stations. It is possible that the existing IMB can be adapted via a 300V interface module to a test battery with voltage significantly greater than 50V. Recently a new concept was conceived for the calibration, algorithm and electronics of the IMB. That algorithm and calibration for that concept have been physically validated. The principal feature of the new electronics is the floating current source excitation of the battery under test. The single ended current excitation of the battery under test, used in the 50V IMB, requires that the negative terminal of the test battery must be the analog ground for the IMB. The new floating current technique allows the test battery to be fully high impedance isolated for a measurement. That isolation will improve IMB noise immunity and enable interrogation of cells internal to a battery module. All these techniques still use the same rapid concept for impedance measurement with the IMB. The purpose of this disclosure is to provide an overview of the analytical validation for three concepts to interface the floating current excitation to a high voltage battery. Recursive simulation models were used in different test scenarios to validate the various new concepts. The analysis will show that it is possible to interface the floating signal current to obtain an impedance measurement on a high voltage test battery. Additionally, the analysis will investigate stress seen by electronics while testing a 300V battery.

  8. Review of Adult Electrical Burn Injury Outcomes Worldwide: An Analysis of Low-Voltage vs High-Voltage Electrical Injury.

    Science.gov (United States)

    Shih, Jessica G; Shahrokhi, Shahriar; Jeschke, Marc G

    The aims of this article are to review low-voltage vs high-voltage electrical burn complications in adults and to identify novel areas that are not recognized to improve outcomes. An extensive literature search on electrical burn injuries was performed using OVID MEDLINE, PubMed, and EMBASE databases from 1946 to 2015. Studies relating to outcomes of electrical injury in the adult population (≥18 years of age) were included in the study. Forty-one single-institution publications with a total of 5485 electrical injury patients were identified and included in the present study. Fourty-four percent of these patients were low-voltage injuries (LVIs), 38.3% high-voltage injuries (HVIs), and 43.7% with voltage not otherwise specified. Forty-four percentage of studies did not characterize outcomes according to LHIs vs HVIs. Reported outcomes include surgical, medical, posttraumatic, and others (long-term/psychological/rehabilitative), all of which report greater incidence rates in HVI than in LVI. Only two studies report on psychological outcomes such as posttraumatic stress disorder. Mortality rates from electrical injuries are 2.6% in LVI, 5.2% in HVI, and 3.7% in not otherwise specified. Coroner's reports revealed a ratio of 2.4:1 for deaths caused by LVI compared with HVI. HVIs lead to greater morbidity and mortality than LVIs. However, the results of the coroner's reports suggest that immediate mortality from LVI may be underestimated. Furthermore, on the basis of this analysis, we conclude that the majority of studies report electrical injury outcomes; however, the majority of them do not analyze complications by low vs high voltage and often lack long-term psychological and rehabilitation outcomes after electrical injury indicating that a variety of central aspects are not being evaluated or assessed.

  9. Design of 154 kV Extra-High-Voltage Prototype SF6 Bushing for Superconducting Electric Power Applications

    Science.gov (United States)

    Koo, Ja-yoon; Seong, Jae-gyu; Hwang, Jae-sang; Lee, Bang-wook; Lee, Sang-hwa

    2012-09-01

    One of the critical components to be developed for high-voltage superconducting devices, such as superconducting transformers, cables, and fault current limiters, is a high-voltage bushing to supply a high current to devices without insulation difficulties in cryogenic environments. Unfortunately, suitable bushings for high-temperature-superconductivity (HTS) equipment have not been fully developed to address cryogenic insulation issues. As a fundamental step towards developing the optimum design of the 154 kV prototype SF6 bushing of HTS devices, the puncture and creepage breakdown voltages of glass-fiber-reinforced-plastic (GFRP) were analyzed with a variety of configurations of electrodes and gap distances in the insulation material. And design factors of high-voltage cryogenic bushings were obtained from the result of tests. Finally, the withstand voltage tests of manufacturing a 154 kV extra-high-voltage (EHV) prototype bushing has been performed. Consequently, we verified the insulation level of the newly designed 154 kV EHV cryogenic prototype bushings for superconducting electric power applications.

  10. Advances in high voltage insulation and arc interruption in SF6 and vacuum

    CERN Document Server

    Maller, V N

    1982-01-01

    Advances in High Voltage Insulation and Arc Interruption in SF6 and Vacuum deals with high voltage breakdown and arc extinction in sulfur hexafluoride (SF6) and high vacuum, with special emphasis on the application of these insulating media in high voltage power apparatus and devices. The design and developmental aspects of various high voltage power apparatus using SF6 and high vacuum are highlighted. This book is comprised of eight chapters and opens with a discussion on electrical discharges in SF6 and high vacuum, along with the properties and handling of SF6 gas. The following chapters fo

  11. Method and system for a gas tube switch-based voltage source high voltage direct current transmission system

    Energy Technology Data Exchange (ETDEWEB)

    She, Xu; Chokhawala, Rahul Shantilal; Zhou, Rui; Zhang, Di; Sommerer, Timothy John; Bray, James William

    2016-12-13

    A voltage source converter based high-voltage direct-current (HVDC) transmission system includes a voltage source converter (VSC)-based power converter channel. The VSC-based power converter channel includes an AC-DC converter and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and a DC-AC inverter include at least one gas tube switching device coupled in electrical anti-parallel with a respective gas tube diode. The VSC-based power converter channel includes a commutating circuit communicatively coupled to one or more of the at least one gas tube switching devices. The commutating circuit is configured to "switch on" a respective one of the one or more gas tube switching devices during a first portion of an operational cycle and "switch off" the respective one of the one or more gas tube switching devices during a second portion of the operational cycle.

  12. Laboratory Investigation on Lightning Flashes to High Voltage Transmission Lines%Laboratory Investigation on Lightning Flashes to High Voltage Transmission Lines

    Institute of Scientific and Technical Information of China (English)

    Thongchai Disyadej; Stanislaw Grzybowski

    2011-01-01

    This paper presents an investigation on the attractive width of high voltage transmission lines to lightning strikes. In order to design the optimal lightning protection, the estimated number of lightning flashes on the line, which is based on its attractive width, needs to be determined. The investigation was performed using experiments with model tests at the Mississippi State University High Voltage Laboratory. For laboratory experiments, a total of 2,100 negative and positive switching impulse voltages were applied to transmission line models from a conducting rod, which represented a lightning downward leader. Different tested models of transmission lines on a scale of 1:100 were used. The effects of overhead ground wires, phase conductors, tower structures, and the magnitude and polarity of lightning strokes were also studied. The attractive width increased gradually with the height of overhead ground wires and towers as well as the magnitude of the lightning stroke current. Impulse polarity had an impact on the at- tractive width, and the attractive width for negative polarity was larger than that {or positive polarity. The taller tower had more effect on flash distribution to transmission lines than the shorter one. The experimental results agree with the actual transmission line observations published in literature. The new expressions for the attractive width of transmission lines, based on the experimental results, were established. The accurate estimation of the attractive width can help electric power utilities plan transmission systems reliably and economically. The detailed description of the back- ground problem, proposed method, experimental results, and analysis are presented in this paper.

  13. High-Voltage LED Light Engine with Integrated Driver

    Energy Technology Data Exchange (ETDEWEB)

    Soer, Wouter [Lumileds LLC, San Jose, CA (United States)

    2016-02-29

    LED luminaires have seen dramatic changes in cost breakdown over the past few years. The LED component cost, which until recently was the dominant portion of luminaire cost, has fallen to a level of the same order as the other luminaire components, such as the driver, housing, optics etc. With the current state of the technology, further luminaire performance improvement and cost reduction is realized most effectively by optimization of the whole system, rather than a single component. This project focuses on improving the integration between LEDs and drivers. Lumileds has developed a light engine platform based on low-cost high-power LEDs and driver topologies optimized for integration with these LEDs on a single substrate. The integration of driver and LEDs enables an estimated luminaire cost reduction of about 25% for targeted applications, mostly due to significant reductions in driver and housing cost. The high-power LEDs are based on Lumileds’ patterned sapphire substrate flip-chip (PSS-FC) technology, affording reduced die fabrication and packaging cost compared to existing technology. Two general versions of PSS-FC die were developed in order to create the desired voltage and flux increments for driver integration: (i) small single-junction die (0.5 mm2), optimal for distributed lighting applications, and (ii) larger multi-junction die (2 mm2 and 4 mm2) for high-power directional applications. Two driver topologies were developed: a tapped linear driver topology and a single-stage switch-mode topology, taking advantage of the flexible voltage configurations of the new PSS-FC die and the simplification opportunities enabled by integration of LEDs and driver on the same board. A prototype light engine was developed for an outdoor “core module” application based on the multi-junction PSS-FC die and the single-stage switch-mode driver. The light engine meets the project efficacy target of 128 lm/W at a luminous flux

  14. High-Voltage LED Light Engine with Integrated Driver

    Energy Technology Data Exchange (ETDEWEB)

    Soer, Wouter [Lumileds LLC, San Jose, CA (United States)

    2016-02-29

    LED luminaires have seen dramatic changes in cost breakdown over the past few years. The LED component cost, which until recently was the dominant portion of luminaire cost, has fallen to a level of the same order as the other luminaire components, such as the driver, housing, optics etc. With the current state of the technology, further luminaire performance improvement and cost reduction is realized most effectively by optimization of the whole system, rather than a single component. This project focuses on improving the integration between LEDs and drivers. Lumileds has developed a light engine platform based on low-cost high-power LEDs and driver topologies optimized for integration with these LEDs on a single substrate. The integration of driver and LEDs enables an estimated luminaire cost reduction of about 25% for targeted applications, mostly due to significant reductions in driver and housing cost. The high-power LEDs are based on Lumileds’ patterned sapphire substrate flip-chip (PSS-FC) technology, affording reduced die fabrication and packaging cost compared to existing technology. Two general versions of PSS-FC die were developed in order to create the desired voltage and flux increments for driver integration: (i) small single-junction die (0.5 mm2), optimal for distributed lighting applications, and (ii) larger multi-junction die (2 mm2 and 4 mm2) for high-power directional applications. Two driver topologies were developed: a tapped linear driver topology and a single-stage switch-mode topology, taking advantage of the flexible voltage configurations of the new PSS-FC die and the simplification opportunities enabled by integration of LEDs and driver on the same board. A prototype light engine was developed for an outdoor “core module” application based on the multi-junction PSS-FC die and the single-stage switch-mode driver. The light engine meets the project efficacy target of 128 lm/W at a luminous flux greater than 4100 lm, a correlated

  15. The Investigation of Field Plate Design in 500 V High Voltage NLDMOS

    Directory of Open Access Journals (Sweden)

    Donghua Liu

    2015-01-01

    Full Text Available This paper presents a 500 V high voltage NLDMOS with breakdown voltage (VBD improved by field plate technology. Effect of metal field plate (MFP and polysilicon field plate (PFP on breakdown voltage improvement of high voltage NLDMOS is studied. The coeffect of MFP and PFP on drain side has also been investigated. A 500 V NLDMOS is demonstrated with a 37 μm drift length and optimized MFP and PFP design. Finally the breakdown voltage 590 V and excellent on-resistance performance (Rsp = 7.88 ohm * mm2 are achieved.

  16. Improvement of high-voltage staircase drive circuit waveform for high-intensity therapeutic ultrasound

    Science.gov (United States)

    Tamano, Satoshi; Jimbo, Hayato; Azuma, Takashi; Yoshizawa, Shin; Fujiwara, Keisuke; Itani, Kazunori; Umemura, Shin-Ichiro

    2016-07-01

    Recently, in the treatment of diseases such as cancer, noninvasive or low-invasive modality, such as high-intensity focused ultrasound (HIFU), has been put into practice as an alternative to open surgery. HIFU induces thermal ablation of the target tissue to be treated. To improve the efficiency of HIFU, we have proposed a “triggered-HIFU” technique, which uses the combination of a short-duration, high-voltage transmission and a long-duration, medium-voltage transmission. In this method, the transmission device must endure high peak voltage for the former and the high time-average power for the latter. The triggered-HIFU sequence requires electronic scanning of the HIFU focus to maximize its thermal efficiency. Therefore, the transmission device must drive an array transducer with the number of elements on the order of a hundred or more, which requires that each part of the device that drives each element must be compact. The purpose of this work is to propose and construct such a transmission device by improving the staircase drive circuit, which we previously proposed. The main point of improvement is that both N and P MOSFETs are provided for each staircase voltage level instead of only one of them. Compared with the previous ultrasonic transmission circuit, high-voltage spikes were significantly reduced, the power consumption was decreased by 26.7%, and the transmission circuit temperature rise was decreased by 14.5 °C in the triggered-HIFU heating mode.

  17. Power supply design for the filament of the high-voltage electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lige; Yang, Lei; Yang, Jun, E-mail: jyang@mail.hust.edu.cn; Huang, Jiang; Liu, Kaifeng; Zuo, Chen

    2015-12-21

    The filament is a key component for the electron emission in the high-voltage electron accelerator. In order to guarantee the stability of the beam intensity and ensure the proper functioning for the power supply in the airtight steel barrel, an efficient filament power supply under accurate control is required. The paper, based on the dual-switch forward converter and synchronous rectification technology, puts forward a prototype of power supply design for the filament of the high-voltage accelerator. The simulation is conducted with MATLAB-Simulink on the main topology and the control method. Loss analysis and thermal analysis are evaluated using the FEA method. Tests show that in this prototype, the accuracy of current control is higher than 97.5%, and the efficiency of the power supply reaches 87.8% when the output current is 40 A.

  18. Daikin Advanced Lithium Ion Battery Technology – High Voltage Electrolyte - REVISED

    Energy Technology Data Exchange (ETDEWEB)

    Sunstrom, Joseph [Daikin America, Inc., Orangeburg, NY (United States); Hendershot, Ron E. [Daikin America, Inc., Orangeburg, NY (United States)

    2017-03-06

    An evaluation of high voltage electrolytes which contain fluorochemicals as solvents/additive has been completed with the objective of formulating a safe, stable electrolyte capable of operation to 4.6 V. Stable cycle performance has been demonstrated in LiNi1/3Mn1/3Co1/3O2 (NMC111)/graphite cells to 4.5 V. The ability to operate at high voltage results in significant energy density gain (>30%) which would manifest as longer battery life resulting in higher range for electric vehicles. Alternatively, a higher energy density battery can be made smaller without sacrificing existing energy. In addition, the fluorinated electrolytes examined showed better safety performance when tested in abuse conditions. The results are promising for future advanced battery development for vehicles as well as other applications.

  19. Design of a high frequency low voltage CMOS operational amplifier

    Directory of Open Access Journals (Sweden)

    Priyanka Kakoty

    2011-03-01

    Full Text Available A method is presented in this paper for the design of a high frequency CMOS operational amplifier (Op-Amp which operates at 3V power supply using tsmc 0.18 micron CMOS technology. The OPAMPdesigned is a two-stage CMOS OPAMP followed by an output buffer. This Operational Transconductance Amplifier (OTA employs a Miller capacitor and is compensated with a current buffer compensation technique. The unique behaviour of the MOS transistors in saturation region not only allows a designer to work at a low voltage, but also at a high frequency. Designing of two-stage op-ampsis a multi-dimensional-optimization problem where optimization of one or more parameters may easily result into degradation of others. The OPAMP is designed to exhibit a unity gain frequency of 2.02GHzand exhibits a gain of 49.02dB with a 60.50 phase margin. As compared to the conventional approach, the proposed compensation method results in a higher unity gain frequency under the same load condition.Design has been carried out in Tanner tools. Simulation results are verified using S-edit and W-edit.

  20. Design of a high frequency low voltage CMOS operational amplifier

    Directory of Open Access Journals (Sweden)

    Priyanka Kakoty

    2011-03-01

    Full Text Available A method is presented in this paper for the design of a high frequency CMOS operational amplifier (Op-Amp which operates at 3V power supply using tsmc 0.18 micron CMOS technology. The OPAMPdesigned is a two-stage CMOS OPAMP followed by an output buffer. This OperationalTransconductance Amplifier (OTA employs a Miller capacitor and is compensated with a current buffercompensation technique. The unique behaviour of the MOS transistors in saturation region not onlyallows a designer to work at a low voltage, but also at a high frequency. Designing of two-stage op-ampsis a multi-dimensional-optimization problem where optimization of one or more parameters may easilyresult into degradation of others. The OPAMP is designed to exhibit a unity gain frequency of 2.02GHzand exhibits a gain of 49.02dB with a 60.50 phase margin. As compared to the conventional approach, theproposed compensation method results in a higher unity gain frequency under the same load condition.Design has been carried out in Tanner tools. Simulation results are verified using S-edit and W-edit.

  1. Characteristics and Breakdown Behaviors of Polysilicon Resistors for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Xiao-Yu Tang

    2015-01-01

    Full Text Available With the rapid development of the power integrated circuit technology, polysilicon resistors have been widely used not only in traditional CMOS circuits, but also in the high voltage applications. However, there have been few detailed reports about the polysilicon resistors’ characteristics, like voltage and temperature coefficients and breakdown behaviors which are critical parameters of high voltage applications. In this study, we experimentally find that the resistance of the polysilicon resistor with a relatively low doping concentration shows negative voltage and temperature coefficients, while that of the polysilicon resistor with a high doping concentration has positive voltage and temperature coefficients. Moreover, from the experimental results of breakdown voltages of the polysilicon resistors, it could be deduced that the breakdown of polysilicon resistors is thermally rather than electrically induced. We also proposed to add an N-type well underneath the oxide to increase the breakdown voltage in the vertical direction when the substrate is P-type doped.

  2. Note: Complementary metal-oxide-semiconductor high voltage pulse generation circuits.

    Science.gov (United States)

    Sun, Jiwei; Wang, Pingshan

    2013-10-01

    We present two types of on-chip pulse generation circuits. The first is based on CMOS pulse-forming-lines (PFLs). It includes a four-stage charge pump, a four-stacked-MOSFET switch and a 5 mm long PFL. The circuit is implemented in a 0.13 μm CMOS process. Pulses of ~1.8 V amplitude with ~135 ps duration on a 50 Ω load are obtained. The obtained voltage is higher than 1.6 V, the rated operating voltage of the process. The second is a high-voltage Marx generator which also uses stacked MOSFETs as high voltage switches. The output voltage is 11.68 V, which is higher than the highest breakdown voltage (~10 V) of the CMOS process. These results significantly extend high-voltage pulse generation capabilities of CMOS technologies.

  3. Push-pull with recovery stage high-voltage DC converter for PV solar generator

    Science.gov (United States)

    Nguyen, The Vinh; Aillerie, Michel; Petit, Pierre; Pham, Hong Thang; Vo, Thành Vinh

    2017-02-01

    A lot of systems are basically developed on DC-DC or DC-AC converters including electronic switches such as MOS or bipolar transistors. The limits of efficiency are quickly reached when high output voltages and high input currents are needed. This work presents a new high-efficiency-high-step-up based on push-pull DC-DC converter integrating recovery stages dedicated to smart HVDC distributed architecture in PV solar energy production systems. Appropriate duty cycle ratio assumes that the recovery stage work with parallel charge and discharge to achieve high step-up voltage gain. Besides, the voltage stress on the main switch is reduced with a passive clamp circuit and thus, low on-state resistance Rdson of the main switch can be adopted to reduce conduction losses. Thus, the efficiency of a basic DC-HVDC converter dedicated to renewable energy production can be further improved with such topology. A prototype converter is developed, and experimentally tested for validation.

  4. A Four-Phase High Voltage Conversion Ratio Bidirectional DC-DC Converter for Battery Applications

    Directory of Open Access Journals (Sweden)

    Li-Kun Xue

    2015-06-01

    Full Text Available This study presents a four-phase interleaved high voltage conversion ratio bidirectional DC-DC converter circuit based on coupled inductors and switched capacitors, which can eliminate the defects of conventional high voltage conversion ratio bidirectional DC-DC converters in terms of high-voltage/current stress, less efficiency and low-power limitation. Parallel channels are used to reduce current stress at the low-voltage side and series connected switched capacitors are used to enlarge voltage conversion ratio, reduce voltage stress and achieve auto current sharing. This paper proposes the operation principle, feature analysis and optimization design considerations. On this basis the objectives of high voltage conversion ratio, low voltage/current stress, high power density, high efficiency and high-power applications can be achieved. Some experimental results based on a 500 W prototype converter (24 V to 48 V at low-voltage side, 400 V at high-voltage side are given to verify the theoretical analysis and the effectiveness of the proposed converter.

  5. Characterization of the voltage control systems and speed of a synchronous machine of high power for short circuit testing; Caracterizacion de los sistemas de control de voltaje y velocidad de una maquina sincrona de alta potencia para pruebas de corto circuito

    Energy Technology Data Exchange (ETDEWEB)

    Segura Ozuna, Victor Octavio; Hernandez Rodriguez, Isaura Victoria; Alcaide Godinez, Indira Xochiquetzal; Garduno Ramirez, Raul; Montero Cervantes, Julio Cesar [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Ruiz Rodriguez, Genaro; Martinez Torres; Ricardo [CFE-LAPEM, Irapuato, Guanajuato (Mexico)

    2012-07-01

    This paper introduces a characterization of the behavior of the speed and voltage control systems of a special purpose synchronous machine (GCC) based on measuring and monitoring physical signals, and recording of the sampled waveforms. Basically, the GCC supplies the energy to perform high-power short-circuits tests to certify electrical equipment and components, as required by the Comision Federal de Electricidad (CFE) in Mexico. The GCC operates alternately as motor and generator. With the GCC operating as motor, speed control during startup, acceleration, re-acceleration and braking is carried out by a static frequency converter (SFC). Complementary, the voltage controller manipulates excitation power to control terminal voltage when the GCC operates as generator and regulates excitation current when the GCC operates as motor. Compared to conventional voltage regulation systems, which must go off in case of short-circuit, the GCC voltage regulator must keep controlling field excitation to maintain the required line current and terminal voltage during short-circuit tests. Monitoring of physical signals was carried out with a portable data acquisition system based on SCXI and PXI digital platforms. A total of 78 signals were monitored with a 6 kHz sampling rate that was enough to obtain detailed signal waveforms. Data captured was processed and plotted for analysis. The signal graphs show the current real behavior of both, the voltage control system and the speed control system, and constitute a precise characterization of their behavior. [Spanish] Este documento presenta una caracterizacion del comportamiento de los sistemas de control de velocidad y voltaje de una maquina sincrona de proposito especial (GCC) basada en la medicion y monitoreo de senales fisicas, asi como en el registro de las formas de onda muestreadas. Basicamente, la GCC suministra la energia para efectuar pruebas de corto circuito de alta potencia para certificar equipo y componentes

  6. BEHAVIOUR OF BACKFILL MATERIALS FOR ELECTRICAL GROUNDING SYSTEMS UNDER HIGH VOLTAGE CONDITIONS

    Directory of Open Access Journals (Sweden)

    S. C. LIM

    2015-06-01

    Full Text Available Backfill materials like Bentonite and cement are effective in lowering grounding resistance of electrodes for a considerable period. During lightning, switching impulses and earth fault occurrences in medium and high voltage networks, the grounding system needs to handle extremely high currents either for a short duration or prolonged period respectively. This paper investigates the behaviour of bentonite, cement and sand under impulse and alternating high voltage (50Hz conditions. Fulguritic-formation was observed in all materials under alternating high voltage. The findings reveal that performance of grounding systems under high voltage conditions may significantly change from the outcomes anticipated at design stage.

  7. SOFT-SWITCHED HIGH STEP-UP DC-DC CONVERTER WITH HIGH VOLTAGE GAIN

    Directory of Open Access Journals (Sweden)

    J.C. PAUL IMMANUEL

    2013-04-01

    Full Text Available This paper presents a new design of soft switched high step-up dc-dc converter with high voltage gain which is suitable for high power applications such as Uninterruptible Power System (UPS, Photo Voltaic system and hybrid electric vehicles. The emergence of this front-end converter is to improve the shape of active input current given to the system. This converter proposes Soft-Switching technique to achieve ZVS turn on of active switches and ZCS turn off of diodes using Lr - Cr resonance in the auxiliary circuit. Therefore reduces the switching losses. Comparatively the voltage conversion ratio of this converter is higher when compared with the ordinary boost converter. Hence the voltage gain of this converter is also higher. A simulation platform is created using MATLAB which illustrates the ZVS and ZCS operation of the switches and diodes. Open loop and closed loop controlled converter systems are modelled and simulated.

  8. Preparation of Power Distribution System for High Penetration of Renewable Energy Part I. Dynamic Voltage Restorer for Voltage Regulation Pat II. Distribution Circuit Modeling and Validation

    Science.gov (United States)

    Khoshkbar Sadigh, Arash

    Part I: Dynamic Voltage Restorer In the present power grids, voltage sags are recognized as a serious threat and a frequently occurring power-quality problem and have costly consequence such as sensitive loads tripping and production loss. Consequently, the demand for high power quality and voltage stability becomes a pressing issue. Dynamic voltage restorer (DVR), as a custom power device, is more effective and direct solutions for "restoring" the quality of voltage at its load-side terminals when the quality of voltage at its source-side terminals is disturbed. In the first part of this thesis, a DVR configuration with no need of bulky dc link capacitor or energy storage is proposed. This fact causes to reduce the size of the DVR and increase the reliability of the circuit. In addition, the proposed DVR topology is based on high-frequency isolation transformer resulting in the size reduction of transformer. The proposed DVR circuit, which is suitable for both low- and medium-voltage applications, is based on dc-ac converters connected in series to split the main dc link between the inputs of dc-ac converters. This feature makes it possible to use modular dc-ac converters and utilize low-voltage components in these converters whenever it is required to use DVR in medium-voltage application. The proposed configuration is tested under different conditions of load power factor and grid voltage harmonic. It has been shown that proposed DVR can compensate the voltage sag effectively and protect the sensitive loads. Following the proposition of the DVR topology, a fundamental voltage amplitude detection method which is applicable in both single/three-phase systems for DVR applications is proposed. The advantages of proposed method include application in distorted power grid with no need of any low-pass filter, precise and reliable detection, simple computation and implementation without using a phased locked loop and lookup table. The proposed method has been verified

  9. Design and Development of a Series Switch for High Voltage in RF Heating

    Science.gov (United States)

    Patel, Himanshu K.; Shah, Deep; Thacker, Mauli; Shah, Atman

    2013-02-01

    Plasma is the fourth state of matter. To sustain plasma in its ionic form very high temperature is essential. RF heating systems are used to provide the required temperature. Arching phenomenon in these systems can cause enormous damage to the RF tube. Heavy current flows across the anode-cathode junction, which need to be suppressed in minimal time for its protection. Fast-switching circuit breakers are used to cut-off the load from the supply in cases of arching. The crowbar interrupts the connection between the high voltage power supply (HVPS) and the RF tube for a temporary period between which the series switch has to open. The crowbar shunts the current across the load but in the process leads to short circuiting the HVPS. Thus, to protect the load as well as the HVPS a series switch is necessary. This paper presents the design and development of high voltage Series Switch for the high power switching applications. Fiber optic based Optimum triggering scheme is designed and tested to restrict the time delay well within the stipulated limits. The design is well supported with the experimental results for the whole set-up along with the series switch at various voltage level before its approval for operation at 5.2 kV.

  10. An Underappreciated Radiation Hazard from High Voltage Electrodes in Vacuum

    CERN Document Server

    West, Adam; DeMille, David; West, Elizabeth; Panda, Cristian; Doyle, John; Gabrielse, Gerald; Kryskow, Adam; Mitchell, Corinne

    2016-01-01

    The use of high voltage (HV) electrodes in vacuum is commonplace in physics laboratories. In such systems, it has long been known that electron emission from an HV cathode can lead to bremsstrahlung X-rays; indeed, this is the basic principle behind the operation of standard X-ray sources. However, in laboratory setups where X-ray production is not the goal and no electron source is deliberately introduced, field-emitted electrons accelerated by HV can produce X-rays as an unintended hazardous byproduct. Both the level of hazard and the safe operating regimes for HV vacuum electrode systems are not widely appreciated, at least in university laboratories. A reinforced awareness of the radiation hazards associated with vacuum HV setups would be beneficial. We present a case study of a HV vacuum electrode device operated in a university atomic physics laboratory. We describe the characterisation of the observed X-ray radiation, its relation to the observed leakage current in the device, the steps taken to contai...

  11. An Underappreciated Radiation Hazard from High Voltage Electrodes in Vacuum.

    Science.gov (United States)

    West, Adam D; Lasner, Zack; DeMille, David; West, Elizabeth P; Panda, Cristian D; Doyle, John M; Gabrielse, Gerald; Kryskow, Adam; Mitchell, Corinne

    2017-01-01

    The use of high voltage (HV) electrodes in vacuum is commonplace in physics laboratories. In such systems, it has long been known that electron emission from an HV cathode can lead to bremsstrahlung x rays; indeed, this is the basic principle behind the operation of standard x-ray sources. However, in laboratory setups where x-ray production is not the goal and no electron source is deliberately introduced, field-emitted electrons accelerated by HV can produce x rays as an unintended hazardous byproduct. Both the level of hazard and the safe operating regimes for HV vacuum electrode systems are not widely appreciated, at least in university laboratories. A reinforced awareness of the radiation hazards associated with vacuum HV setups would be beneficial. The authors present a case study of a HV vacuum electrode device operated in a university atomic physics laboratory. They describe the characterization of the observed x-ray radiation, its relation to the observed leakage current in the device, the steps taken to contain and mitigate the radiation hazard, and suggested safety guidelines.

  12. A new aluminium-ion battery with high voltage, high safety and low cost.

    Science.gov (United States)

    Sun, Haobo; Wang, Wei; Yu, Zhijing; Yuan, Yan; Wang, Shuai; Jiao, Shuqiang

    2015-07-28

    A new kind of Al-ion battery with carbon paper as the cathode, high-purity Al foil as the anode and ionic liquid as the electrolyte is proposed in this work. The significance of the presented battery is going to be an extremely high average voltage plateau of ca. 1.8 V vs. Al(3+)/Al.

  13. High Bandwidth Zero Voltage Injection Method for Sensorless Control of PMSM

    DEFF Research Database (Denmark)

    Ge, Xie; Lu, Kaiyuan; Kumar, Dwivedi Sanjeet

    2014-01-01

    High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses to be inj...... in a fast current regulation performance. Injection of zero voltage also minimizes the inverter voltage error effects caused by the dead-time.......High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses...... to be injected before the position may be estimated. In this paper, a single pulse zero voltage injection method is proposed. The rotor position is directly estimated from the current ripple at half of the switching frequency. No machine parameters are needed and using of filters is avoided. This results...

  14. 高压输电线路无线电干扰和电磁散射对GPS卫星信号影响测试及分析%Test and Analysis on Effect of High Voltage Transmission Lines Corona Radio Interference and Scattering to GPS Signal

    Institute of Scientific and Technical Information of China (English)

    刘兴发; 尹晖; 邬雄; 张建功; 裴春明; 干喆渊

    2011-01-01

    of GPS satellite signal scattering change the satellite signal amplitude,phase and path,and GPS receivers may produce positioning error.Through the field test,data received from 24 spots are tested.The test results show that,with the points test line 0 m,far from 30 m,60 m,120 m and 180 m,coordinate precision hardly changes,and no obvious rule of distance is found.GPS in high voltage transmission line erea can reduce theprotection distance of 50 m.

  15. [Transient high frequency nodal rhythm after a high voltage electric shock. Report of one case].

    Science.gov (United States)

    Supervía, August; Del Baño, Francisco; Aguirre, Alfons; Membrilla, Estela

    2013-09-01

    Electrical shock can cause a direct myocardial damage and different types of arrhythmias, which are uncommon and occur more often when there is a high voltage exposure. We report a 19-year-old male that received a high voltage shock, falling thereafter from an altitude of four meters. On admission to the emergency room, he had second and third degree burns in the right hand and the left thigh. The electrocardiogram showed a nodal rhythm of 72 beats per minute. After four hours of monitoring, sinus rhythm returned spontaneously.

  16. Method and apparatus for connecting high voltage leads to a high temperature super-conducting transformer

    Science.gov (United States)

    Golner, Thomas M.; Mehta, Shirish P.

    2005-07-26

    A method and apparatus for connecting high voltage leads to a super-conducting transformer is provided that includes a first super-conducting coil set, a second super-conducting coil set, and a third super-conducting coil set. The first, second and third super-conducting coil sets are connected via an insulated interconnect system that includes insulated conductors and insulated connectors that are utilized to connect the first, second, and third super-conducting coil sets to the high voltage leads.

  17. Design of a high voltage stimulator chip for a stroke rehabilitation system.

    Science.gov (United States)

    Zeng, Lei; Yi, Xin; Lu, Sheng; Lou, Yuan; Jiang, Jianfei; Qu, Hongen; Lan, Ning; Wang, Guoxing

    2013-01-01

    This paper describes the design of an 8-channel high voltage stimulator chip for rehabilitation of stroke patients through surface stimulation, which requires high stimulation currents and high compliance voltage. The chip gets stimulation control data through its Serial Peripheral Interface (SPI), and can accordingly generate biphasic stimulation currents with different amplitudes, duration, frequencies and polarities independently for each channel. The current driver is implemented with thick oxide devices with a supply voltage up to 90V. The chip is designed in a 0.35εm X-FAB high voltage process.

  18. Development of high-voltage pulse generator with variable amplitude and duration

    Science.gov (United States)

    Upadhyay, J.; Sharma, M. L.; Ahuja, Aakash B.; Navathe, C. P.

    2014-06-01

    A high voltage pulse generator with variable amplitude (100-3000 V) and duration (100-2000 μs) has been designed and developed. The variable duration pulse has been generated by adopting a simple and novel technique of varying the turn off delay time of a high voltage Metal Oxide Semiconductor Field Effect Transistor (MOSFET) based switch by varying external gate resistance. The pulse amplitude is made variable by adjusting biasing supply of the high voltage switch. The high voltage switch has been developed using a MOSFET based stack of 3 kV rating with switching time of 7 ns.

  19. Design and Construction of Low Cost High Voltage dc Power Supply for Constant Power Operation

    Science.gov (United States)

    Kumar, N. S.; Jayasankar, V.

    2013-06-01

    Pulsed load applications like laser based systems need high voltage dc power supplies with better regulation characteristics. This paper presents the design, construction and testing of dc power supply with 1 kV output at 300 W power level. The designed converter has half bridge switched mode power supply (SMPS) configuration with 20 kHz switching. The paper covers the design of half bridge inverter, closed loop control, High frequency transformer and other related electronics. The designed power supply incorporates a low cost OPAMP based feedback controller which is designed using small signal modelling of the converter. The designed converter was constructed and found to work satisfactorily as per the specifications.

  20. A novel on-chip high to low voltage power conversion circuit

    Institute of Scientific and Technical Information of China (English)

    Wang Hui; Wang Songlin; Lai Xinquan; Ye Qiang; Mou Zaixin; Li Xianrui; Guo Baolong

    2009-01-01

    A novel power supply transform technique for high voltage IC based on the TSMC 0.6μm BCD process is achieved. An adjustable bandgap voltage reference is presented which is different from the traditional power supply transform technique. It can be used as an internal power supply for high voltage IC by using the push-pull output stage to enhance its load capability. High-order temperature compensated circuit is designed to ensure the precision of the reference. Only 0.01 mm2 area is occupied using this novel power supply technique. Compared with traditional technique, 50% of the area is saved, 40% quiescent power loss is decreased, and the temperature coefficient of the reference is only 4.48 ppm/℃. Compared with the traditional LDO (low dropout) regulator, this power conversion architecture does not need external output capacitance and decreases the chip-pin and external components, so the PCB area and design cost are also decreased. The testing results show that this circuit works well.

  1. Modeling and experimental testing activity of the Voltage Optimization Unit

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Hu, Junjie; Marinelli, Mattia

    cost investments of to the system operator, thus a proactive tap algorithm is developed and tested in this project, relying on local measurements. In addition, we also compared the experimental result with the one simulated in the DigSilent PowerFactory software environment (the software used...... the voltage problems in presence of photovoltaic distributed generation, using Bistrup distribution grid (DONG Energy) as a test case. This second report presents the experimental results of the testing activity of the Voltage Optimization Unit (VOU), i.e., a distribution transformer with single-phase on......-load tap changers (OLTC) in an experimental low voltage grid. Both the transformer internal behavior and its effective operations under different unbalanced bidirectional power flow conditions have been investigated. Moreover, different control logics are analyzed based on their control objectives and control...

  2. A High Voltage High Frequency Resonant Inverter for Supplying DBD Devices with Short Discharge Current Pulses

    OpenAIRE

    Bonnin, Xavier; Brandelero, Julio; Videau, Nicolas; Piquet, Hubert; Meynard, Thierry

    2014-01-01

    International audience; In this paper, the merits of a high-frequency resonant converter for supplying dielectric barrier discharges (DBD) devices are established. It is shown that, thanks to its high-frequency operating condition, such a converter allows to supply DBD devices with short discharge current pulses, a high repetition rate, and to control the injected power. In addition, such a topology eliminates the matter of connecting a high-voltage transformer directly across the DBD device ...

  3. Investigation of the Effects of Facility Background Pressure on the Performance and Voltage-Current Characteristics of the High Voltage Hall Accelerator

    Science.gov (United States)

    Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Spektor, Rostislav

    2014-01-01

    The National Aeronautics and Space Administration (NASA) Science Mission Directorate In-Space Propulsion Technology office is sponsoring NASA Glenn Research Center to develop a 4 kW-class Hall thruster propulsion system for implementation in NASA science missions. A study was conducted to assess the impact of varying the facility background pressure on the High Voltage Hall Accelerator (HiVHAc) thruster performance and voltage-current characteristics. This present study evaluated the HiVHAc thruster performance in the lowest attainable background pressure condition at NASA GRC Vacuum Facility 5 to best simulate space-like conditions. Additional tests were performed at selected thruster operating conditions to investigate and elucidate the underlying physics that change during thruster operation at elevated facility background pressure. Tests were performed at background pressure conditions that are three and ten times higher than the lowest realized background pressure. Results indicated that the thruster discharge specific impulse and efficiency increased with elevated facility background pressure. The voltage-current profiles indicated a narrower stable operating region with increased background pressure. Experimental observations of the thruster operation indicated that increasing the facility background pressure shifted the ionization and acceleration zones upstream towards the thruster's anode. Future tests of the HiVHAc thruster are planned at background pressure conditions that are expected to be two to three times lower than what was achieved during this test campaign. These tests will not only assess the impact of reduced facility background pressure on thruster performance, voltage-current characteristics, and plume properties; but will also attempt to quantify the magnitude of the ionization and acceleration zones upstream shifting as a function of increased background pressure.

  4. High-Mixed-Voltage Analog and RF Circuit Techniques for Nanoscale CMOS

    CERN Document Server

    Mak, Pui-In

    2012-01-01

    This book presents high-/mixed-voltage analog and radio frequency (RF) circuit techniques for developing low-cost multistandard wireless receivers in nm-length CMOS processes.  Key benefits of high-/mixed-voltage RF and analog CMOS circuits are explained, state-of-the-art examples are studied, and circuit solutions before and after voltage-conscious design are compared. Three real design examples are included, which demonstrate the feasibility of high-/mixed-voltage circuit techniques.    Provides a valuable summary and real case studies of the state-of-the-art in high-/mixed-voltage circuits and systems; Includes novel high-/mixed-voltage analog and RF circuit techniques – from concept to practice; Describes the first high-voltage-enabled mobile-TVRF front-end in 90nm CMOS and the first mixed-voltage full-band mobile-TV Receiver in 65nm CMOS; Demonstrates the feasibility of high-/mixed-voltage circuit techniques with real design examples.  

  5. Capacitance of High-Voltage Coaxial Cable in Plasma Immersion Ion Implantation

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Plasma immersion ion implantation (PIII) is an excellent technique for the surface modification of complex-shaped components. Owing to pulsed operation mode of the high voltage and large slew rate, the capacitance on the high-voltage coaxial cable can be detrimental to the processand cannot be ignored. In fact, a significant portion of the rise-time/fall-time of the implantation voltage pulse and big initial current can be attributed to the coaxial cable.

  6. Threshold-voltage modulated phase change heterojunction for application of high density memory

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Baihan; Tong, Hao, E-mail: tonghao@hust.edu.cn; Qian, Hang; Miao, Xiangshui [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China); School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2015-09-28

    Phase change random access memory is one of the most important candidates for the next generation non-volatile memory technology. However, the ability to reduce its memory size is compromised by the fundamental limitations inherent in the CMOS technology. While 0T1R configuration without any additional access transistor shows great advantages in improving the storage density, the leakage current and small operation window limit its application in large-scale arrays. In this work, phase change heterojunction based on GeTe and n-Si is fabricated to address those problems. The relationship between threshold voltage and doping concentration is investigated, and energy band diagrams and X-ray photoelectron spectroscopy measurements are provided to explain the results. The threshold voltage is modulated to provide a large operational window based on this relationship. The switching performance of the heterojunction is also tested, showing a good reverse characteristic, which could effectively decrease the leakage current. Furthermore, a reliable read-write-erase function is achieved during the tests. Phase change heterojunction is proposed for high-density memory, showing some notable advantages, such as modulated threshold voltage, large operational window, and low leakage current.

  7. The thermal regime around buried submarine high-voltage cables

    Science.gov (United States)

    Emeana, C. J.; Hughes, T. J.; Dix, J. K.; Gernon, T. M.; Henstock, T. J.; Thompson, C. E. L.; Pilgrim, J. A.

    2016-08-01

    The expansion of offshore renewable energy infrastructure and the need for trans-continental shelf power transmission require the use of submarine high-voltage (HV) cables. These cables have maximum operating surface temperatures of up to 70 °C and are typically buried 1-2 m beneath the seabed, within the wide range of substrates found on the continental shelf. However, the heat flow pattern and potential effects on the sedimentary environments around such anomalously high heat sources in the near-surface sediments are poorly understood. We present temperature measurements from a 2-D laboratory experiment representing a buried submarine HV cable, and identify the thermal regimes generated within typical unconsolidated shelf sediments—coarse silt, fine sand and very coarse sand. We used a large (2 × 2.5 m2) tank filled with water-saturated spherical glass beads (ballotini) and instrumented with a buried heat source and 120 thermocouples to measure the time-dependent 2-D temperature distributions. The observed and corresponding Finite Element Method simulations of the steady state heat flow regimes and normalized radial temperature distributions were assessed. Our results show that the heat transfer and thus temperature fields generated from submarine HV cables buried within a range of sediments are highly variable. Coarse silts are shown to be purely conductive, producing temperature increases of >10 °C up to 40 cm from the source of 60 °C above ambient; fine sands demonstrate a transition from conductive to convective heat transfer between cf. 20 and 36 °C above ambient, with >10 °C heat increases occurring over a metre from the source of 55 °C above ambient; and very coarse sands exhibit dominantly convective heat transfer even at very low (cf. 7 °C) operating temperatures and reaching temperatures of up to 18 °C above ambient at a metre from the source at surface temperatures of only 18 °C. These findings are important for the surrounding near

  8. High-PSRR High-Order Curvature-Compensated CMOS Bandgap Voltage Reference

    Institute of Scientific and Technical Information of China (English)

    Qianneng Zhou; Yunsong Li; Jinzhao Lin; Hongjuan Li; Yu Pang; Wei Luo

    2015-01-01

    A high⁃PSRR high⁃order curvature⁃compensated CMOS bandgap voltage reference (BGR), which has the performances of high power supply rejection ratio ( PSRR) and low temperature coefficient, is designed in SMIC 0�18 μm CMOS process. Compared to the conventional curvature⁃compensated BGR which adopted a piecewise⁃linear current, the temperature characterize of the proposed BGR is effectively improved by adopting two kinds of current including a piecewise⁃linear current and a current proportional 1�5 party to the absolute temperature T. By adopting a low dropout ( LDO) regulator whose output voltage is the operating supply voltage of the proposed BGR core circuit instead of power supply voltage VDD , the proposed BGR with LDO regulator achieves a well PSRR performance than the BGR without LDO regulator. Simulation results show that the proposed BGR with LDO regulator achieves a temperature coefficient of 2�1 × 10-6/℃ with a 1�8 V power supply voltage and a line regulation of 4�9 μV/V at 27 ℃. The proposed BGR with LDO regulator at 10 Hz, 100 Hz, 1 kHz, 10 kHz and 100 kHz have the PSRR of -106�388, -106�388, -106�38, -105�93 and-88�67 dB respectively.

  9. A test technique for measuring lightning-induced voltages on aircraft electrical circuits

    Science.gov (United States)

    Walko, L. C.

    1974-01-01

    The development of a test technique used for the measurement of lightning-induced voltages in the electrical circuits of a complete aircraft is described. The resultant technique utilizes a portable device known as a transient analyzer capable of generating unidirectional current impulses similar to lightning current surges, but at a lower current level. A linear relationship between the magnitude of lightning current and the magnitude of induced voltage permitted the scaling up of measured induced values to full threat levels. The test technique was found to be practical when used on a complete aircraft.

  10. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Fasanella, Giuseppe

    2016-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillating lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  11. High precision, low disturbance calibration system for the CMS Barrel Electromagnetic Calorimeter High Voltage apparatus

    Science.gov (United States)

    Fasanella, G.

    2017-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillation lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3%/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  12. Investigating Enhancement Mode Gallium Nitride Power FETs in High Voltage, High Frequency Soft Switching Converters

    DEFF Research Database (Denmark)

    Nour, Yasser; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2016-01-01

    An increased attention has been detected to develop smaller and lighter high voltage power converters in the range of 50V to 400V domain. The main applications for these converters are mainly focused for Power over Ethernet (PoE), LED lighting and AC adapters. This work will discuss a study...

  13. Investigating Enhancement Mode Gallium Nitride Power FETs in High Voltage, High Frequency Soft Switching Converters

    DEFF Research Database (Denmark)

    Nour, Yasser; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2016-01-01

    An increased attention has been detected to develop smaller and lighter high voltage power converters in the range of 50V to 400V domain. The main applications for these converters are mainly focused for Power over Ethernet (PoE), LED lighting and AC adapters. This work will discuss a study of us...

  14. Atomic layer deposition encapsulated activated carbon electrodes for high voltage stable supercapacitors.

    Science.gov (United States)

    Hong, Kijoo; Cho, Moonkyu; Kim, Sang Ouk

    2015-01-28

    Operating voltage enhancement is an effective route for high energy density supercapacitors. Unfortunately, widely used activated carbon electrode generally suffers from poor electrochemical stability over 2.5 V. Here we present atomic layer deposition (ALD) encapsulation of activated carbons for high voltage stable supercapacitors. Two-nanometer-thick Al2O3 dielectric layers are conformally coated at activated carbon surface by ALD, well-maintaining microporous morphology. Resultant electrodes exhibit excellent stability at 3 V operation with 39% energy density enhancement from 2.5 V operation. Because of the protection of surface functional groups and reduction of electrolyte degradation, 74% of initial voltage was maintained 50 h after full charge, and 88% of capacitance was retained after 5000 cycles at 70 °C accelerated test, which correspond to 31 and 17% improvements from bare activated carbon, respectively. This ALD-based surface modification offers a general method to enhance electrochemical stability of carbon materials for diverse energy and environmental applications.

  15. Study on the Test Method of Initiation Energy Matching for High Voltage Pulse Power Source and Slapper%高压脉冲功率源与冲击片雷管发火能量匹配关系特性试验方法

    Institute of Scientific and Technical Information of China (English)

    韩克华; 王丽萍; 任西; 褚恩义

    2012-01-01

    Aimed at the problem of initiation energy matching for high voltage pulse power source with cable and slapper, the test method of initiation energy matching was put forward. For the cable connected to the output of high voltage pulse power source condition, the data of the short circuit discharge were obtained by the test device, meanwhile, the theoretic analysis and verification test of slapper initiation were carried out The results indicated that when the cable of 100mm was connected to the output of high voltage pulse power source, the initiation voltage of slapper was risen 300V, the corresponding output energy equals to that without cable. The test method not only protect the initiation device and retrench the test cost, but also ensure the reliability of slapper initiation.%针对高压脉冲功率源接入引出电缆后与冲击片雷管发火能量的匹配问题,提出了高压脉冲功率源与冲击片雷管发火能量的匹配关系特性试验方法,通过试验装置测试了接入引出电缆后冲击片雷管短路放电性能参数,并进行了理论分析及冲击片雷管发火验证试验.结果表明:在脉冲功率源输出端增加100mm的引出电缆后,冲击片雷管发火电压需提升300V,此时输出能量等价于未接入引出电缆时的发火能量.该方法在冲击片雷管发火试验以及传爆序列试验中,既能保护起爆装置,节约试验成本,又能保证冲击片雷管可靠起爆.

  16. Integrated Reconfigurable High-Voltage Transmitting Circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Jørgensen, Ivan Harald Holger

    2014-01-01

    -out and measurements are performed on the integrated circuit. The transmitting circuit is reconfigurable externally making it able to drive a wide variety of CMUTs. The transmitting circuit can generate several pulse shapes, pulse voltages up to 100 V, maximum pulse range of 50 V and frequencies up to 5 MHz. The area...

  17. Analysis of transistor and snubber turn-off dynamics in high-frequency high-voltage high-power converters

    Science.gov (United States)

    Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.

    1982-01-01

    Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.

  18. Analysis of transistor and snubber turn-off dynamics in high-frequency high-voltage high-power converters

    Science.gov (United States)

    Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.

    Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.

  19. A new low-voltage and high-speed sense amplifier for flash memory

    Institute of Scientific and Technical Information of China (English)

    Guo Jiarong; Ran Feng

    2011-01-01

    A new low-voltage and high-speed sense amplifier is presented,based on a very simple direct currentmode comparison.It adopts low-voltage reference current extraction and a dynamic output method to realize its performance indicators such as low voltage,low power and high precision.The proposed amplifier can sense a 0.5 μA current gap and work with a lowest voltage of 1 V.In addition,the current power of a single amplifier is optimized by 15%.

  20. High Voltage EEE Parts for EMA/EHA Applications on Manned Launch Vehicles

    Science.gov (United States)

    Griffin, Trent; Young, David

    2011-01-01

    The objective of this paper is an assessment of high voltage electronic components required for high horsepower electric thrust vector control (TVC) systems for human spaceflight launch critical application. The scope consists of creating of a database of available Grade 1 electrical, electronic and electromechanical (EEE) parts suited to this application, a qualification path for potential non-Grade 1 EEE parts that could be used in these designs, and pathfinder testing to validate aspects of the proposed qualification plan. Advances in the state of the art in high power electric power systems enable high horsepower electric actuators, such as the electromechnical actuator (EMA) and the electro-hydrostatic actuator (EHA), to be used in launch vehicle TVC systems, dramaticly reducing weight, complexity and operating costs. Designs typically use high voltage insulated gate bipolar transistors (HV-IGBT). However, no Grade 1 HV-IGBT exists and it is unlikely that market factors alone will produce such high quality parts. Furthermore, the perception of risk, the lack of qualification methodoloy, the absence of manned space flight heritage and other barriers impede the adoption of commercial grade parts onto the critical path. The method of approach is to identify high voltage electronic component types and key parameters for parts currently used in high horsepower EMA/EHA applications, to search for higher quality substitutes and custom manufacturers, to create a database for these parts, and then to explore ways to qualify these parts for use in human spaceflight launch critical application, including grossly derating and possibly treating hybrid parts as modules. This effort is ongoing, but results thus far include identification of over 60 HV-IGBT from four manufacturers, including some with a high reliability process flow. Voltage ranges for HV-IGBT have been identified, as has screening tests used to characterize HV-IGBT. BSI BS ISO 21350 Space systems Off

  1. High Energy Density Battery Lithium Thionyl Chloride Improved Reverse Voltage Design.

    Science.gov (United States)

    1981-12-01

    BATTERY LITHIUM THIONYL CHLORIDE IMPROVED R-ETC(U) DEC 81 A E ZOLLA N660011-C-0310...HIGH ENERGY DENSITY BATTERY LITHIUM THIONYL CHLORIDE IMPROVED REVERSE VOLTAGE DESIGN Dr. A. E. Zolla Altus Corporation C:1 1610 Crane Court San Jose...reverse aide If necesary and identify by block number) Lithium Battery Lithium Thionyl Chloride High Energy Density Battery Voltage Reversal Battery

  2. 30 CFR 75.802 - Protection of high-voltage circuits extending underground.

    Science.gov (United States)

    2010-07-01

    ... underground. 75.802 Section 75.802 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.802 Protection of high-voltage circuits extending underground. (a) Except as...

  3. Debugging on High-voltage Power Supply,Focusing Power Supply and Magnetic Field Power Supply

    Institute of Scientific and Technical Information of China (English)

    TU; Rui

    2015-01-01

    High-voltage power supply,focusing power supply and magnetic field power supply are the main parts of the power supply system of the EMIS(Electro-Magnetic Isotope Separator)supplying the ion source.In 2015,a high-voltage power supply,power supply for focusing and

  4. High-voltage, short-risetime pulse generator based on a ferrite pulse sharpener

    Energy Technology Data Exchange (ETDEWEB)

    Seddon, N.; Thornton, E.

    1988-11-01

    A high-voltage, short-risetime pulse generator is described. The generator consists of a Marx bank, which produces an initial high-voltage pulse, and a ferrite pulse sharpener that reduces the risetime of the pulse. The generator delivers 70-kV, 350-ps risetime pulses into a 50-..cap omega.. load.

  5. MATHEMATICAL MODEL OF HYBRID ELECTRIC VEHICLE HIGH-VOLTAGE BATTERY IDENTIFICATION

    Directory of Open Access Journals (Sweden)

    S. Serikov

    2010-01-01

    Full Text Available The mathematical model of hybrid electric vehicle NiMH high-voltage battery is obtained. This model allows to explore the interaction of vehicle tractive electric drive and high-voltage battery at the electric motive power motion and in the process of recuperation of braking kinetic energy.

  6. High voltage bus and auxiliary heater control system for an electric or hybrid vehicle

    Science.gov (United States)

    Murty, Balarama Vempaty

    2000-01-01

    A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

  7. Design and Implementation of a High Efficiency, Low Component Voltage Stress, Single-Switch High Step-Up Voltage Converter for Vehicular Green Energy Systems

    Directory of Open Access Journals (Sweden)

    Yu-En Wu

    2016-09-01

    Full Text Available In this study, a novel, non-isolated, cascade-type, single-switch, high step-up DC/DC converter was developed for green energy systems. An integrated coupled inductor and voltage lift circuit were applied to simplify the converter structure and satisfy the requirements of high efficiency and high voltage gain ratios. In addition, the proposed structure is controllable with a single switch, which effectively reduces the circuit cost and simplifies the control circuit. With the leakage inductor energy recovery function and active voltage clamp characteristics being present, the circuit yields optimizable conversion efficiency and low component voltage stress. After the operating principles of the proposed structure and characteristics of a steady-state circuit were analyzed, a converter prototype with 450 W, 40 V of input voltage, 400 V of output voltage, and 95% operating efficiency was fabricated. The Renesas MCU RX62T was employed to control the circuits. Experimental results were analyzed to validate the feasibility and effectiveness of the proposed system.

  8. Optical fiber sensor of partial discharges in High Voltage DC experiments

    Science.gov (United States)

    Búa-Núñez, I.; Azcárraga-Ramos, C. G.; Posada-Román, J. E.; Garcia-Souto, J. A.

    2014-05-01

    A setup simulating High Voltage DC (HVDC) transformers barriers was developed to demonstrate the effectiveness of an optical fiber (OF) sensor in detecting partial discharges (PD) under these peculiar conditions. Different PD detection techniques were compared: electrical methods, and acoustic methods. Standard piezoelectric sensors (R15i-AST) and the above mentioned OF sensors were used for acoustic detection. The OF sensor was able to detect PD acoustically with a sensitivity better than the other detection methods. The multichannel instrumentation system was tested in real HVDC conditions with the aim of analyzing the behavior of the insulation (mineral oil/pressboard).

  9. Synthesis gas regeneration electrotechnology using volume high-voltage pulsed discharges: corona and barrier ones

    Directory of Open Access Journals (Sweden)

    M.I. Boyko

    2014-09-01

    Full Text Available Factory testing of a created high-voltage complex (plant has been conducted. The complex consists of two pulse generators with the repetition rate of up to 50,000 pulses per second and load reactors with pulsed discharges - corona and barrier ones. Transistor (IGBT keys are used as energy switches. The efficient mode of coke gas methane conversion (steam reforming to syngas has been obtained with application of the complex created. A unidirectional action of the pulsed discharges, the gas mixture temperature, and a nickel catalyst has reduced the specific energy consumption for synthesis gas regeneration during the conversion. A feasible mechanism of this conversion is described.

  10. Evaluation and Simulation of Black-box Arc Models for High-Voltage Circuit-Breakers

    OpenAIRE

    Gustavsson, Niklas

    2004-01-01

    The task for this Master thesis was to evaluate different black-box arc models for circuit-breakers with the purpose of finding criteria for the breaking ability. A black-box model is a model that requires no knowledge from the user of the underlying physical processes. Black-box arc models have been used in circuit-breaker development for many years. Arc voltages from tests made in the High Power Laboratory in Ludvika were used for validation, along with the resistance calculated at current ...

  11. HIGH VOLTAGE SMALL – SIZED ALTERNATIVE CURRENT RESISTIVE DIVIDERS FROM MICROWIRE

    Directory of Open Access Journals (Sweden)

    Berzan V.P.

    2011-04-01

    Full Text Available The paper discusses the design parameters and characteristics of the new product, the resistive voltage divider produced from microwire for measuring high-voltage alternating current. Resistive dividers are designed for use in AC circuits and power-frequency electric traction network traffic. Dividers have smaller mass-dimensional size compared with the measuring voltage transformers and higher accuracy class 0.2 at a fixed frequency.

  12. Analysis of cutting-edge techniques in the high voltage and high power adjustable speed drive systems

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The high voltage and high power adjustable speed drive (ASD) system is one of the most attractive fields in power electronics, and it is also a very crucial technique for energy saving and emission reduction. This paper discussed and analyzed the main cutting-edge knowledge and issues in the process of exploiting the high voltage and high power ASD system.

  13. Degradation of Photovoltaic Modules Under High Voltage Stress in the Field: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    del Cueto, J. A.; Rummel, S. R.

    2010-08-01

    The degradation in performance for eight photovoltaic (PV) modules stressed at high voltage (HV) is presented. Four types of modules--tandem-junction and triple-junction amorphous thin-film silicon, plus crystalline and polycrystalline silicon modules--were tested, with a pair of each biased at opposite polarities. They were deployed outdoors between 2001 and 2009 with their respective HV leakage currents through the module encapsulation continuously monitored with a data acquisition system, along with air temperature and relative humidity. For the first 5 years, all modules were biased continuously at fixed 600 VDC, day and night. In the last 2 years, the modules were step-bias stressed cyclically up and down in voltage between 10 and 600 VDC, in steps of tens to hundreds of volts. This allowed characterization of leakage current versus voltage under a large range of temperature and moisture conditions, facilitating determination of leakage paths. An analysis of the degradation is presented, along with integrated leakage charge. In HV operation: the bulk silicon modules degraded either insignificantly or at rates of 0.1%/yr higher than modules not biased at HV; for the thin-film silicon modules, the added loss rates are insignificant for one type, or 0.2%/yr-0.6%/yr larger for the other type.

  14. Humidity Steady State Low Voltage Testing of MLCCs (Based on NESC Technical Assessment Report)

    Science.gov (United States)

    Sampson, Mike; Brusse, Jay; Teverovsky, Alexander

    2011-01-01

    Review of the low voltage reduced Insulation Resistance (IR) failure phenomenon in Multilayer ceramic capacitors (MLCCs)and NASA approaches to contend with this risk. 1. Analyze published materials on root cause mechanisms. 2. Investigate suitability of current test methods to assess MLCC lots for susceptibility. 3. Review current NASA parts selection and application guidelines in consideration of benefits vs. disadvantages.

  15. Loading Analysis of Modular Multi-level Converter for Offshore High-voltage DC Application under Various Grid Faults

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang;

    2016-01-01

    The modular multi-level converter has become an interesting candidate in high-voltage DC systems due to its higher voltage levels and modular construction. Low-voltage ride-through is an important grid requirement for modular multi-level converter–high-voltage DC since not only causes control cha...... be of importance for the design of the cooling system....

  16. Investigation of Threshold Voltage Variability at High Temperature Using Takeuchi Plot

    Science.gov (United States)

    Tsunomura, Takaaki; Nishida, Akio; Hiramoto, Toshiro

    2010-05-01

    The property of metal-oxide-semiconductor field-effect transistors' (MOSFETs) threshold voltage (VT) variability at high temperature is investigated by evaluating the device matrix array test element group (DMA-TEG). It is revealed that VT variation is lower at high temperature than at room temperature, and that VT at high temperature has a strong correlation with VT at room temperature. The normal property of VT variability both at room and high temperatures is validated using the normal probability plot. The decrease in VT variation at high temperature stems from the reduction of the channel depletion layer width (Wdep). The temperature dependence of VT variation is evaluated using the Takeuchi plot, the VT variation normalization method. It is revealed that the change in BVT, the parameter of VT variation in the Takeuchi plot, is very small with varying temperature.

  17. Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through

    Directory of Open Access Journals (Sweden)

    Yun Wang

    2014-06-01

    Full Text Available This paper presents a fast coordinated control scheme of the rotor side converter (RSC, the Direct Current (DC chopper and the grid side converter (GSC of doubly fed induction generator (DFIG wind turbine generators (WTGs to improve the low voltage ride through (LVRT and high voltage ride through (HVRT capability of the DFIG WTGs. The characteristics of DFIG WTGs under voltage sags and swells were studied focusing on the DFIG WTG stator flux and rotor voltages during the transient periods of grid voltage changes. The protection schemes of the rotor crowbar circuit and the DC chopper circuit were proposed considering the characteristics of the DFIG WTGs during voltage changes. The fast coordinated control of RSC and GSC were developed based on the characteristic analysis in order to realize efficient LVRT and HVRT of the DFIG WTGs. The proposed fast coordinated control schemes were verified by time domain simulations using Matlab-Simulink.

  18. Summary of transient high-voltage calculations for the FRX-C experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kewish, R.W. Jr.; Rej, D.J.

    1982-06-01

    Calculations of the electrical circuit equations are performed over a wide range of parameters corresponding to the FRX-C field-reversed THETA-pinch experiment at Los Alamos. Without any plasma or external damping, serious voltage doubling and quadrupling of the main capacitor bank charge voltage are observed. These oscillating high voltages are found to be adequately suppressed by the strategic placement of external snubber circuitry. On the other hand, no doubling of the THETA-pinch preionization bank charge voltage is found. Calculations of the equations for the z-pinch preionization circuit are also performed.

  19. DEVELOPMENT OF HIGH-VOLTAGE HIGH-FREQUENCY POWER SUPPLY FOR OZONE GENERATION

    Directory of Open Access Journals (Sweden)

    NACERA HAMMADI

    2016-05-01

    Full Text Available A high-voltage high-frequency power supply for ozone generation is presented in this paper. Ozone generation is intended to be used in air and in water disinfection. A power stage consisting of a single-phase full bridge inverter for regulating the output power, a current push-pull inverter (driver and a control circuit are described and analyzed. This laboratory build power supply using a high voltage ferrite transformer and a PIC microcontroller was employed to energize a dielectric barrier discharge (DBD ozone generator. The inverter working on the basis of control strategy is of simple structure and has a variation range of the working frequency in order to obtain the optimal frequency value. The experimental results concerning electrical characterization and water treatment using a cylindrical DBD ozone generator supplied by this power supply are given in the end.

  20. Performance of a Remote High Voltage Power Supply for the Phase II Upgrade of the ATLAS Tile Calorimeter

    CERN Document Server

    Vazeille, Francois; The ATLAS collaboration

    2015-01-01

    The experience gained in the working of the present High Voltage system of the Tile calorimeter of the ATLAS detector and the new HL-LHC constraints, in particular the increase of the radiation, lead to the proposal of moving the embedded regulation system to be a remote system in the counting room, by adding easily new functionalities. This system is using the same regulation scheme as the current one and distributes the individual High Voltage settings with multi-conductor cables. The tests show that it reaches the same performance in terms of regulation stability and noise, with a permanent access to the electronics.

  1. Spatial and temporal instabilities in high voltage power devices

    Energy Technology Data Exchange (ETDEWEB)

    Milady, Saeed

    2010-01-29

    Dynamic avalanche can occur during the turn-off process of high voltage bipolar devices, e.g. IGBTs and p{sup +}n{sup -}n{sup +} power diodes, that may result in spatial instabilities of the homogeneous current density distribution across the device and the formation of current filaments. Filaments may cause the destruction of the device, mainly because of the high local temperatures. The first part of this work is dedicated to the current filament behavior. The positive feedback mechanisms caused by the transient current flow through the gate capacitance of an IGBT operating under short circuit conditions may result in oscillations and temporal instabilities of the IGBT current. The oscillations may cause electromagnetic interference (EMI). Furthermore, the positive feedback mechanism may accelerate the over-heating of the device and result in a thermal run-away. This is the subject of the second part of this work. In the first part of this work using the device simulation results of power diodes the underlying physical mechanisms of the filament dynamic is investigated. Simulation results of diode structures with evenly distributed doping inhomogeneities show that, the filament motion gets smoother as the distance between the inhomogeneities decreases. Hopping to faraway inhomogeneities turns into the hopping to neighboring ones and finally a smooth motion. In homogeneous structures the slow inhibitory effect of the electron-hole plasma extraction and the fast activation, due to hole current flowing along the filament, result in a smooth filament motion. An analytical model for the filament velocity under isothermal conditions is presented that can reproduce the simulation data satisfactorily. The influence of the boundary conditions on the filament behavior is discussed. The positive beveled edge termination prohibits a long stay of the filament at the edge reducing the risk of filament pinning. Self-heating effects may turn the initially electrically triggered

  2. An Integrated Chip High-Voltage Power Receiver for Wireless Biomedical Implants

    Directory of Open Access Journals (Sweden)

    Vijith Vijayakumaran Nair

    2015-06-01

    Full Text Available In near-field wireless-powered biomedical implants, the receiver voltage largely overrides the compliance of low-voltage power receiver systems. To limit the induced voltage, generally, low-voltage topologies utilize limiter circuits, voltage clippers or shunt regulators, which are power-inefficient methods. In order to overcome the voltage limitation and improve power efficiency, we propose an integrated chip high-voltage power receiver based on the step down approach. The topology accommodates voltages as high as 30 V and comprises a high-voltage semi-active rectifier, a voltage reference generator and a series regulator. Further, a battery management circuit that enables safe and reliable implant battery charging based on analog control is proposed and realized. The power receiver is fabricated in 0.35-μm high-voltage Bipolar-CMOS-DMOStechnology based on the LOCOS0.35-μm CMOS process. Measurement results indicate 83.5% power conversion efficiency for a rectifier at 2.1 mA load current. The low drop-out regulator based on the current buffer compensation and buffer impedance attenuation scheme operates with low quiescent current, reduces the power consumption and provides good stability. The topology also provides good power supply rejection, which is adequate for the design application. Measurement results indicate regulator output of 4 ± 0.03 V for input from 5 to 30 V and 10 ± 0.05 V output for input from 11 to 30 V with load current 0.01–100 mA. The charger circuit manages the charging of the Li-ion battery through all if the typical stages of the Li-ion battery charging profile.

  3. Nonlinear Parasitic Capacitance Modelling of High Voltage Power MOSFETs in Partial SOI Process

    DEFF Research Database (Denmark)

    Fan, Lin; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2016-01-01

    : off-state, sub-threshold region, and on-state in the linear region. A high voltage power MOSFET is designed in a partial Silicon on Insulator (SOI) process, with the bulk as a separate terminal. 3D plots and contour plots of the capacitances versus bias voltages for the transistor summarize...

  4. Response of low voltage networks with high penetration of photovoltaic systems to transmission network faults

    NARCIS (Netherlands)

    Skaloumpakas, K.; Boemer, J.C.; Van Ruitenbeek, E.; Gibescu, M.

    2014-01-01

    The installed capacity of photovoltaic (PV) systems connected to low voltage (LV) networks in Germany has increased to more than 25 GW. Current grid codes still mandate these PV systems to disconnect in case of voltage dips below 0.8 p.u. The resulting response of LV distribution systems with high p

  5. Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Xu, Honghua

    2014-01-01

    This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the DC chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) which is to improve the low voltage ride through (LVRT) and high voltage ride through (...... verified by time domain simulations using MATLAB-Simulink....

  6. Electronics drivers for high voltage dielectric electro active polymer (DEAP) applications

    DEFF Research Database (Denmark)

    Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    ), but the voltage balancing across the series - connected high voltage IGBTs is a critical issue and accordi ngly a novel gate driver circuitry is proposed and equipped; due to the requirements of the audio products, such as low distortion and noise, the multi - level Buck converter based Class - D amplifier...

  7. Development of Fiber Optically Driven Instrument for High-voltage Line Current

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The measurement theorem of fiber optically driven instrument for high-voltage line current is presented. The PLL voltage-frequency-narrow pulse principle and its micro-consumption mechanism are proposed, followed by analysis on the two main factors affecting PLL measurement precision. A software design scheme using 80C196KB micro-controller is introduced. The experiment result is satisfactory.

  8. The Dynamic Fracture Process in Rocks Under High-Voltage Pulse Fragmentation

    Science.gov (United States)

    Cho, Sang Ho; Cheong, Sang Sun; Yokota, Mitsuhiro; Kaneko, Katsuhiko

    2016-10-01

    High-voltage pulse technology has been applied to rock excavation, liberation of microfossils, drilling of rocks, oil and water stimulation, cleaning castings, and recycling products like concrete and electrical appliances. In the field of rock mechanics, research interest has focused on the use of high-voltage pulse technology for drilling and cutting rocks over the past several decades. In the use of high-voltage pulse technology for drilling and cutting rocks, it is important to understand the fragmentation mechanism in rocks subjected to high-voltage discharge pulses to improve the effectiveness of drilling and cutting technologies. The process of drilling rocks using high-voltage discharge is employed because it generates electrical breakdown inside the rocks between the anode and cathode. In this study, seven rock types and a cement paste were electrically fractured using high-voltage pulse discharge to investigate their dielectric breakdown properties. The dielectric breakdown strengths of the samples were compared with their physical and mechanical properties. The samples with dielectric fractured were scanned using a high-resolution X-ray computed tomography system to observe the fracture formation associated with mineral constituents. The fracture patterns of the rock samples were analyzed using numerical simulation for high-voltage pulse-induced fragmentation that adopts the surface traction and internal body force conditions.

  9. Effects of elevation change on mental stress in high-voltage transmission tower construction workers.

    Science.gov (United States)

    Hsu, Feng-Wen; Lin, Chiuhsiang Joe; Lee, Yung-Hui; Chen, Hung-Jen

    2016-09-01

    High-voltage transmission tower construction is a high-risk operation due to the construction site locations, extreme climatic factors, elevated working surfaces, and narrow working space. To comprehensively enhance our understanding of the psychophysiological phenomena of workers in extremely high tower constructions, we carried out a series of field experiments to test and compare three working surface heights in terms of frequency-domain heart rate variability (HRV) measurements. Twelve experienced male workers participated in this experiment. The dependent variables, namely, heart rate (HR), normalized low-frequency power (nLF), normalized high-frequency power (nHF), and LF-to-HF power ratio (LF/HF), were measured with the Polar RS800CX heart rate monitor. The experimental results indicated that the task workload was similar between working surface heights. Tower construction workers perceived an increased level of mental stress as working surface height increased.

  10. Experimental study on high-voltage solar array sustained arc discharge induced by high charging

    Institute of Scientific and Technical Information of China (English)

    LI Kai; XIE ErQing; WANG Li; LIU YanXia; YANG Yang; SUN YanZheng; CUI XinYu; MAI ShengLi

    2007-01-01

    It has been reported that sustained arc discharge induced by electrostatic discharge (ESD) could cause permanent damage to high-power and high-voltage solar array of spacecrafts. The paper focuses on ESD simulating experiments on Si and GaAs samples, and induces sustained arc discharge. The physical mechanism of sustained arc discharge is discussed by comparing the charging/discharging phenomena between Si and GaAs samples. The experiments show that sustained arc discharge can produce a permanent short-circuit channel between solar cell strings through which the solar array's photovoltaic power may flow out sustainedly. The analyses show that sustained arc discharge strongly depends on solar array structure, solar array operating voltage, ESD characteristics and cell materials.

  11. Experimental study on high-voltage solar array sustained arc discharge induced by high charging

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    It has been reported that sustained arc discharge induced by electrostatic discharge (ESD) could cause permanent damage to high-power and high-voltage solar array of spacecrafts. The paper focuses on ESD simulating experiments on Si and GaAs samples, and induces sustained arc discharge. The physical mechanism of sustained arc discharge is discussed by comparing the charging/discharging phenomena between Si and GaAs samples. The experiments show that sustained arc discharge can produce a permanent short-circuit channel between solar cell strings through which the solar array’s photovoltaic power may flow out sustainedly. The analyses show that sustained arc discharge strongly depends on solar array structure, solar array operating voltage, ESD characteristics and cell materials.

  12. Installation for Treatment of Agricultural Products Using High-Voltage Discharges

    Directory of Open Access Journals (Sweden)

    Popescu V.S.

    2015-12-01

    Full Text Available The paper presents the results of the study on the determination and optimization of construction and technology parameters of an electro hydraulic installation developed for research in view of its use in primary processing of agricultural products. Unlike other processing technologies, the proposed technology using electro hydraulic effect requires the application of an installation, which is simple in terms of construction, has low cost, is reliable, easy to use and can be widely applied in various branches of agriculture including primary processing of agricultural products and for sterilizing liquids. The problem of using electro hydraulic effect consists in the correct dimensioning of the installation parameters to obtain high voltage pulses, in comparison with the dimensions of the chamber with electrodes, wherein the liquid processing is carried out. For dimensioning and development of the proposed installation, the necessary parameters were determined by calculation and were confirmed by conducting operational tests. The performed calculation and tests on the operation of the installation under laboratory conditions gave the possibility of dimensioning and optimization of the construction and technological parameters of electro-hydraulic installation, i.e. voltage level, the distance between the electrodes, the volume of the treated liquid, the treatment pulse number and the energy pulsed discharge. The values of the design parameters have allowed to develop and commission the installation, which will allow further tests on use of the electro-hydraulic effect in the processing the agricultural products in the Republic of Moldova.

  13. High Voltage Power Converter for Large Wind Turbine

    DEFF Research Database (Denmark)

    Sztykiel, Michal

    performance has been achieved by the transformer-less turbine with a back-to-back modular multilevel converter (MMC) topology, which is single grounded only through its DC link common-mode point. It has also occurred that the results derived from losses and short circuit analyses have become advantageous over...... system operates at 20 kV level - identical as for the collector distribution network. Medium voltage operation allows the converter unit along with the filter to be installed on the base platform inside the tower. In this manner, more space in the nacelle can be flexibly accommodated by the mechanical...

  14. Comparative study of high voltage bushing designs suitable for apparatus containing cryogenic helium gas

    Science.gov (United States)

    Rodrigo, H.; Graber, L.; Kwag, D. S.; Crook, D. G.; Trociewitz, B.

    2013-10-01

    The high voltage bushing forms a critical part of any termination on cables, transformers and other power system devices. Cryogenic entities such as superconducting cables or fault current limiters add more complexity to the design of the bushing. Even more complex are bushings designed for superconducting devices which are cooled by high pressure helium gas. When looking for a bushing suitable for dielectric cable tests in a helium gas cryostat no appropriate device could be found that fulfilled the criterion regarding partial discharge inception voltage level. Therefore we decided to design and manufacture a bushing in-house. In the present work we describe the dielectric tests and operational experience on three types of bushings: One was a modified commercially available ceramics feed through which we adopted for our special need. The second bushing was made of an epoxy resin, with an embedded copper squirrel cage arrangement at the flange, extending down about 30 cm into the cold end of the bushing. This feature reduced the electric field on the surface of the bushing to a negligible value. The third bushing was based on a hollow body consisting of glass fiber reinforced polymer and stainless steel filled with liquid nitrogen. The measurements showed that the dielectric quality of all three bushings exceeded the requirements for the intended purpose. The partial discharge (PD) data from these studies will be used for the design and fabrication of a cable termination for a specialized application on board a US Navy ship.

  15. Selection of a suitable vegetable oil for high voltage insulation applications

    Science.gov (United States)

    Hosier, I. L.; Guushaa, A.; Vaughan, A. S.; Swingler, S. G.

    2009-08-01

    Many items of high voltage plant employ a liquid both as a dielectric and a coolant. Currently these systems use a mineral oil, however, this suffers from the drawback of being potentially toxic and hence leakages and eventual disposal can be serious issues. To overcome this problem, an increasing trend in the UK is to backfill existing paper/oil cable systems with dodecylbenzene (DDB). This fluid possesses the advantages of improved gas absorption, good dielectric properties and biodegradability; nevertheless it is still derived from crude oil, a non-renewable resource. Vegetable oils offer the added advantage of being renewable although many types are available with very different properties. In order to select a suitable vegetable oil for high voltage applications, a standardised ageing and testing regime is required. In this paper, a wide range of vegetable oils were subjected to controlled laboratory ageing and the resulting aged oils were characterised by a number of analytical techniques. The results from these tests were then used to rank the different oils, and to select the most ageing resistant oil.

  16. Automatic System for the D.C. High Voltage Qualification of the Superconducting Electrical Circuits of the LHC Machine

    CERN Document Server

    Bozzini, D; Russenschuck, Stephan; Bednarek, M; Jurkiewicz, P; Kotarba, A; Ludwin, J; Olek, S

    2008-01-01

    A d.c. high voltage test system has been developed to verify automatically the insulation resistance of the powering circuits of the LHC. In the most complex case, up to 72 circuits share the same volume inside cryogenic lines. Each circuit can have an insulation fault versus any other circuit or versus ground. The system is able to connect up to 80 circuits and apply a voltage up to 2 kV D.C. The leakage current flowing through each circuit is measured within a range of 1 nA to 1.6 mA. The matrix of measurements allows characterizing the paths taken by the currents and locating weak points of the insulation between circuits. The system is composed of a D.C. voltage source and a data acquisition card. The card is able to measure with precision currents and voltages and to drive up to 5 high voltage switching modules offering 16 channels each. A LabVIEW application controls the system for an automatic and safe operation. This paper describes the hardware and software design, the testing methodology and the res...

  17. A New High Frequency Injection Method Based on Duty Cycle Shifting without Maximum Voltage Magnitude Loss

    DEFF Research Database (Denmark)

    Wang, Dong; Lu, Kaiyuan; Rasmussen, Peter Omand

    2015-01-01

    The conventional high frequency signal injection method is to superimpose a high frequency voltage signal to the commanded stator voltage before space vector modulation. Therefore, the magnitude of the voltage used for machine torque production is limited. In this paper, a new high frequency...... injection method, in which high frequency signal is generated by shifting the duty cycle between two neighboring switching periods, is proposed. This method allows injecting a high frequency signal at half of the switching frequency without the necessity to sacrifice the machine fundamental voltage...... amplitude. This may be utilized to develop new position estimation algorithm without involving the inductance in the medium to high speed range. As an application example, a developed inductance independent position estimation algorithm using the proposed high frequency injection method is applied to drive...

  18. Novel substrate trigger SCR-LDMOS stacking structure for high-voltage ESD protection application

    Institute of Scientific and Technical Information of China (English)

    马金荣; 乔明; 张波

    2015-01-01

    A novel substrate trigger semiconductor control rectifier-laterally diffused metal–oxide semiconductor (STSCR-LDMOS) stacked structure is proposed and simulated using the transimission line pulser (TLP) multiple-pulse simulation method in a 0.35-µm, 60-V biploar-CMOS-DMOS (BCD) process without additional masks. On account of a very low holding voltage, it is susceptible to latch-up-like danger for the semiconductor control rectifier-laterally diffused metal–oxide semiconductor (SCR-LDMOS) in high-voltage electro-static discharge (ESD) protection applications. Although the conventional stacking structure has achieved strong latch-up immunity by increasing holding voltage, excessive high trigger voltage does not meet requirements for an ESD protection device. The holding voltage of the proposed stacked structure is proportional to the stacking number, whereas the trigger voltage remains nearly the same. A high holding voltage of 30.6 V and trigger voltage of 75.4 V are achieved.

  19. Voltage dip generator for testing wind turbines connected to electrical networks

    Energy Technology Data Exchange (ETDEWEB)

    Veganzones, C.; Martinez, S.; Platero, C.A.; Blazquez, F.; Ramirez, D.; Arribas, J.R.; Merino, J.; Gordillo, F. [Department of Electrical Engineering, ETSII, Universidad Politecnica de Madrid, C/Jose Gutierrez Abascal 2, 28006 Madrid (Spain); Sanchez, J.A.; Herrero, N. [Department of Civil Engineering, Hydraulics and Energy, ETSICCP, Universidad Politecnica de Madrid, Ciudad Universitaria, s/n. 28040 Madrid (Spain)

    2011-05-15

    This paper describes a new voltage dip generator that allows the shape of the time profile of the voltage generated to be configured. The use of this device as a tool to test the fault ride-through capability of wind turbines connected to the electricity grid can provide some remarkable benefits: First, this system offers the possibility of adapting the main features of the time-voltage profile generated (dip depth, dip duration, the ramp slope during the recovery process after clearing fault, etc.) to the specific requirements set forth by the grid operation codes, in accordance with different network electrical systems standards. Second, another remarkable ability of this system is to provide sinusoidal voltage and current wave forms during the overall testing process without the presence of harmonic components. This is made possible by the absence of electronic converters. Finally, the paper includes results and a discussion on the experimental data obtained with the use of a reduced size laboratory prototype that was constructed to validate the operating features of this new device. (author)

  20. On-chip high-voltage generator design design methodology for charge pumps

    CERN Document Server

    Tanzawa, Toru

    2016-01-01

    This book provides various design techniques for switched-capacitor on-chip high-voltage generators, including charge pump circuits, regulators, level shifters, references, and oscillators.  Readers will see these techniques applied to system design in order to address the challenge of how the on-chip high-voltage generator is designed for Flash memories, LCD drivers, and other semiconductor devices to optimize the entire circuit area and power efficiency with a low voltage supply, while minimizing the cost.  This new edition includes a variety of useful updates, including coverage of power efficiency and comprehensive optimization methodologies for DC-DC voltage multipliers, modeling of extremely low voltage Dickson charge pumps, and modeling and optimum design of AC-DC switched-capacitor multipliers for energy harvesting and power transfer for RFID.

  1. Analysis of trigger behavior of high voltage LDMOS under TLP and VFTLP stress

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Jing; Qian Qinsong; Sun Weifeng; Liu Siyang, E-mail: zhj_seu@126.co [National ASIC System Engineering Research Center, Southeast University, Nanjing 210096 (China)

    2010-01-15

    The physical mechanisms triggering electrostatic discharge (ESD) in high voltage LDMOS power transistors (> 160 V) under transmission line pulsing (TLP) and very fast transmission line pulsing (VFTLP) stress are investigated by TCAD simulations using a set of macroscopic physical models related to previous studies implemented in Sentaurus Device. Under VFTLP stress, it is observed that the triggering voltage of the high voltage LDMOS obviously increases, which is a unique phenomenon compared with the low voltage ESD protection devices like NMOS and SCR. The relationship between the triggering voltage increase and the parasitic capacitances is also analyzed in detail. A compact equivalent circuit schematic is presented according to the investigated phenomena. An improved structure to alleviate this effect is also proposed and confirmed by the experiments. (semiconductor devices)

  2. Process engineering of high voltage alginate encapsulation of mesenchymal stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Gryshkov, Oleksandr, E-mail: gryshkov@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Pogozhykh, Denys, E-mail: pogozhykh@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Zernetsch, Holger, E-mail: zernetsch@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Hofmann, Nicola, E-mail: hofmann@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Mueller, Thomas, E-mail: mueller.thomas@mh-hannover.de [Institute for Transfusion Medicine, Medical School Hannover, D-30625 Hannover (Germany); Glasmacher, Birgit, E-mail: glasmacher@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany)

    2014-03-01

    Encapsulation of stem cells in alginate beads is promising as a sophisticated drug delivery system in treatment of a wide range of acute and chronic diseases. However, common use of air flow encapsulation of cells in alginate beads fails to produce beads with narrow size distribution, intact spherical structure and controllable sizes that can be scaled up. Here we show that high voltage encapsulation (≥ 15 kV) can be used to reproducibly generate spherical alginate beads (200–400 μm) with narrow size distribution (± 5–7%) in a controlled manner under optimized process parameters. Flow rate of alginate solution ranged from 0.5 to 10 ml/h allowed producing alginate beads with a size of 320 and 350 μm respectively, suggesting that this approach can be scaled up. Moreover, we found that applied voltages (15–25 kV) did not alter the viability and proliferation of encapsulated mesenchymal stem cells post-encapsulation and cryopreservation as compared to air flow. We are the first who employed a comparative analysis of electro-spraying and air flow encapsulation to study the effect of high voltage on alginate encapsulated cells. This report provides background in application of high voltage to encapsulate living cells for further medical purposes. Long-term comparison and work on alginate–cell interaction within these structures will be forthcoming. - Highlights: • High voltage alginate encapsulation of mesenchymal stem cells (MSCs) was designed. • Reproducible and spherical alginate beads were generated via high voltage. • Air flow encapsulation was utilized as a comparative approach to high voltage. • High voltage did not alter the viability and proliferation of encapsulated MSCs. • High voltage encapsulation can be scaled up and applied in cell-based therapy.

  3. Realization of a high voltage generator by series connection of floating modules.

    Science.gov (United States)

    Antonini, P; Benato, A; Borsato, E; Carugno, G; Gobbo, R; Montecassiano, F; Pegoraro, M; Pesavento, G; Zago, M; Zotto, P

    2017-02-01

    A high voltage generator built by a series connection of 100 kV modules was produced. The series connection feasibility is ensured by the inherent floating character of each module which is wireless powered by high efficiency photovoltaic cells illuminated by a laser system. Each module is equipped with a control and monitoring board allowing excellent stabilization of the high voltage output. The performance of the system in terms of reliability, stability, and efficiency was evaluated. In particular using a three module setup, we achieved a maximum voltage of 234 kV with stability better than 0.1%.

  4. The effect of high voltage, high frequency pulsed electric field on slain ovine cortical bone.

    Science.gov (United States)

    Asgarifar, Hajarossadat; Oloyede, Adekunle; Zare, Firuz

    2014-04-01

    High power, high frequency pulsed electric fields known as pulsed power (PP) has been applied recently in biology and medicine. However, little attention has been paid to investigate the application of pulse power in musculoskeletal system and its possible effect on functional behavior and biomechanical properties of bone tissue. This paper presents the first research investigating whether or not PP can be applied safely on bone tissue as a stimuli and what will be the possible effect of these signals on the characteristics of cortical bone by comparing the mechanical properties of this type of bone pre and post expose to PP and in comparison with the control samples. A positive buck-boost converter was applied to generate adjustable high voltage, high frequency pulses (up to 500 V and 10 kHz). The functional behavior of bone in response to pulse power excitation was elucidated by applying compressive loading until failure. The stiffness, failure stress (strength) and the total fracture energy (bone toughness) were determined as a measure of the main bone characteristics. Furthermore, an ultrasonic technique was applied to determine and comprise bone elasticity before and after pulse power stimulation. The elastic property of cortical bone samples appeared to remain unchanged following exposure to pulse power excitation for all three orthogonal directions obtained from ultrasonic technique and similarly from the compression test. Nevertheless, the compressive strength and toughness of bone samples were increased when they were exposed to 66 h of high power pulsed electromagnetic field compared to the control samples. As the toughness and the strength of the cortical bone tissue are directly associated with the quality and integrity of the collagen matrix whereas its stiffness is primarily related to bone mineral content these overall results may address that although, the pulse power stimulation can influence the arrangement or the quality of the collagen network

  5. Study on Miniaturized UHF Antennas for Partial Discharge Detection in High-Voltage Electrical Equipment.

    Science.gov (United States)

    Liu, Jingcun; Zhang, Guogang; Dong, Jinlong; Wang, Jianhua

    2015-11-20

    Detecting partial discharge (PD) is an effective way to evaluate the condition of high-voltage electrical equipment insulation. The UHF detection method has attracted attention due to its high sensitivity, strong interference resistance, and ability to locate PDs. In this paper, a miniaturized equiangular spiral antenna (ESA) for UHF detection that uses a printed circuit board is proposed. I-shaped, L-shaped, and C-shaped microstrip baluns were designed to match the impedance between the ESA and coaxial cable and were verified by a vector network analyzer. For comparison, three other types of UHF antenna were also designed: A microstrip patch antenna, a microstrip slot antenna, and a printed dipole antenna. Their antenna factors were calibrated in a uniform electric field of different frequencies modulated in a gigahertz transverse electromagnetic cell. We performed comparison experiments on PD signal detection using an artificial defect model based on the international IEC 60270 standard. We also conducted time-delay test experiments on the ESA sensor to locate a PD source. It was found that the proposed ESA sensor meets PD signal detection requirements. The sensor's compact size makes it suitable for internal installation in high-voltage electrical equipment.

  6. The commercial development of water repellent coatings for high voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, S. R. [ORNL; Daniel, A. [Southwire Company

    2013-10-31

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy?s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

  7. The commercial development of water repellent coatings for high voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, Scott Robert [ORNL

    2013-10-01

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

  8. Study on Miniaturized UHF Antennas for Partial Discharge Detection in High-Voltage Electrical Equipment

    Directory of Open Access Journals (Sweden)

    Jingcun Liu

    2015-11-01

    Full Text Available Detecting partial discharge (PD is an effective way to evaluate the condition of high-voltage electrical equipment insulation. The UHF detection method has attracted attention due to its high sensitivity, strong interference resistance, and ability to locate PDs. In this paper, a miniaturized equiangular spiral antenna (ESA for UHF detection that uses a printed circuit board is proposed. I-shaped, L-shaped, and C-shaped microstrip baluns were designed to match the impedance between the ESA and coaxial cable and were verified by a vector network analyzer. For comparison, three other types of UHF antenna were also designed: A microstrip patch antenna, a microstrip slot antenna, and a printed dipole antenna. Their antenna factors were calibrated in a uniform electric field of different frequencies modulated in a gigahertz transverse electromagnetic cell. We performed comparison experiments on PD signal detection using an artificial defect model based on the international IEC 60270 standard. We also conducted time-delay test experiments on the ESA sensor to locate a PD source. It was found that the proposed ESA sensor meets PD signal detection requirements. The sensor’s compact size makes it suitable for internal installation in high-voltage electrical equipment.

  9. Design of High-Voltage Switch-Mode Power Amplifier Based on Digital-Controlled Hybrid Multilevel Converter

    Directory of Open Access Journals (Sweden)

    Yanbin Hou

    2016-01-01

    Full Text Available Compared with conventional Class-A, Class-B, and Class-AB amplifiers, Class-D amplifier, also known as switching amplifier, employs pulse width modulation (PWM technology and solid-state switching devices, capable of achieving much higher efficiency. However, PWM-based switching amplifier is usually designed for low-voltage application, offering a maximum output voltage of several hundred Volts. Therefore, a step-up transformer is indispensably adopted in PWM-based Class-D amplifier to produce high-voltage output. In this paper, a switching amplifier without step-up transformer is developed based on digital pulse step modulation (PSM and hybrid multilevel converter. Under the control of input signal, cascaded power converters with separate DC sources operate in PSM switch mode to directly generate high-voltage and high-power output. The relevant topological structure, operating principle, and design scheme are introduced. Finally, a prototype system is built, which can provide power up to 1400 Watts and peak voltage up to ±1700 Volts. And the performance, including efficiency, linearity, and distortion, is evaluated by experimental tests.

  10. Results of the 2015 testbeam of a 180 nm AMS High-Voltage CMOS sensor prototype

    CERN Document Server

    Benoit, M; de Mendizabal, J. Bilbao; Chen, H; Chen, K; Di Bello, F.A; Ferrere, D; Golling, T; Gonzalez-Sevilla, S; Iacobucci, G; Lanni, F; Liu, H; Meng, L; Miucci, A; Muenstermann, D; Nessi, M; Peric, I; Rimoldi, M; Ristic, B; Pinto, M. Vicente Barrero; Vossebeld, J; Weber, M; Wu, W; Xu, L

    2016-01-01

    Active pixel sensors based on the High-Voltage CMOS technology are being investigated as a viable option for the future pixel tracker of the ATLAS experiment at the High-Luminosity LHC. This paper reports on the testbeam measurements performed at the H8 beamline of the CERN Super Proton Synchrotron on a High-Voltage CMOS sensor prototype produced in 180 nm AMS technology. Results in terms of tracking efficiency and timing performance, for different threshold and bias conditions, are shown.

  11. Preparation methodology and possible treatments for improved ceramics for high voltage vacuum applications

    CERN Document Server

    Tan, J

    1998-01-01

    The flashover characteristics of an insulator bridged high voltage vacuum gap can play an important role in the overall performance of a high voltage device, for example in the extreme environments of high energy particle accelerators. The detailed preparation of the insulators is, at present, governed by the commercial production methods and by standard bulk cleaning processes, which for a particular application may be far from optimum. The influence of the mechanical preparation, thermal history and particular cleaning technique have been investigated for commercially available alumina samples, with measurement of surface characteristics by scanning electron microscopy and laser diffraction, measurement of the secondary electron emission curve and analysis of the high voltage performance with the possibility of applied fields up to 200kV/cm. The results of the different measurements are discussed in the overall context of the problems encountered in the full sized high voltage devices, and suggestions are m...

  12. A New High Precision Power Detector of Complex Voltage Signals

    Directory of Open Access Journals (Sweden)

    Petrović Predrag B.

    2015-08-01

    Full Text Available A current-mode bipolar power detector based on a novel synthesis of translinear loop squarer/divider is presented. The circuits consist of a single multiple-output current controlled current differencing transconductance amplifier (MO-CCCDTA, two current controlled conveyors (CCCII, and one resistor and one capacitor that are both grounded. The errors related to the signal processing and errors bound were investigated and presented in the paper. The PSpice simulation and experimental results are depicted, and agree well with the theoretical anticipation. The measurement results show that the scheme improves the accuracy of the detector to better than 0.04 % and wide operating frequency range from 50 Hz to 10 MHz. The maximum power consumption of the detector is approximately 5.80 mW, at ±1.2 V supply voltages.

  13. High voltage conditioning of the electrostatic deflector of MARA

    Science.gov (United States)

    Partanen, J.; Johansen, U.; Sarén, J.; Tuunanen, J.; Uusitalo, J.

    2016-06-01

    MARA is a new recoil mass separator in the Accelerator Laboratory of University of Jyväskylä (JYFL-ACCLAB) with a mass resolving power of 250 and an ion-optical configuration of QQQDEDM . In this paper the construction, control and conditioning of its electrostatic deflector are described. The deflector was designed for voltages up to 500 kV accross the gap, corresponding to a 3.6 MV/m field, to accomodate fusion reactions with inverse kinematics. Titanium electrodes with a beam dump opening in the anode are used. The conditioning procedure, which has been used repeatedly to take the deflector to 450 kV, is described, along with the safety systems and precautions that are in place.

  14. Very low power, high voltage base for a Photo Multiplier Tube for the KM3NeT deep sea neutrino telescope

    CERN Document Server

    Timmer, P; Peek, H

    2010-01-01

    The described system is developed in the framework of a deep-sea submerged Very Large Volume neutrino Telescope where photons are detected by a large number of Photo Multiplier Tubes. These PMTs are placed in optical modules (OM). A basic Cockcroft-Walton (CW) voltage multiplier circuit design is used to generate multiple voltages to drive the dynodes of the photomultiplier tube. To achieve a long lifetime and a high reliability the dissipation in the OM must be kept to the minimum. The design is also constrained by size restrictions, load current, voltage range, and the maximum allowable ripple in the output voltage. A surface mount PMT-base PCB prototype is designed and successfully tested. The system draws less than 1.5 mA of supply current at a voltage of 3.3 V with outputs up to -1400 Vdc cathode voltage, a factor 10 less than the commercially available state of the art

  15. Pattern recognition of typical defects in high-voltage storage capacitors based on DC partial discharge

    Institute of Scientific and Technical Information of China (English)

    WU GuangNing; BIAN ShanShan; ZHOU LiRen; ZHANG XueQin; RAN HanZheng; YU ChengLong

    2009-01-01

    High-voltage storage capacitors(hereinafter call capacitors for short)have been widely used in pulsed power technology.In accordance with the actual work conditions of capacitors,direct current partial discharge(DCPD)detection was put forward.The whole test system was based on the impedance balance circuit characterized by good configuration and anti-interference ability.Through DCPD detection on capacitors which contained four typical defects respectively,test results revealed that DCPD signals could well reflect the state of capacitor insulation.DCPD distribution spectra of capacitors containing four typical defects were obviously different.Defects in capacitors could be exactly judged by computer-aided pattern recognition based on support vector machine(SVM).

  16. Pattern recognition of typical defects in high-voltage storage capacitors based on DC partial discharge

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    High-voltage storage capacitors(hereinafter call capacitors for short)have been widely used in pulsed power technology.In accordance with the actual work conditions of capacitors,direct current partial discharge(DCPD)detection was put forward.The whole test system was based on the impedance balance circuit characterized by good configuration and anti-interference ability.Through DCPD detection on capacitors which contained four typical defects respectively,test results revealed that DCPD signals could well reflect the state of capacitor insulation.DCPD distribution spectra of capacitors containing four typical defects were obviously different.Defects in capacitors could be exactly judged by computer–aided pattern recognition based on support vector machine(SVM).

  17. Frequency-Domain Maximum-Likelihood Estimation of High-Voltage Pulse Transformer Model Parameters

    CERN Document Server

    Aguglia, D

    2014-01-01

    This paper presents an offline frequency-domain nonlinear and stochastic identification method for equivalent model parameter estimation of high-voltage pulse transformers. Such kinds of transformers are widely used in the pulsed-power domain, and the difficulty in deriving pulsed-power converter optimal control strategies is directly linked to the accuracy of the equivalent circuit parameters. These components require models which take into account electric fields energies represented by stray capacitance in the equivalent circuit. These capacitive elements must be accurately identified, since they greatly influence the general converter performances. A nonlinear frequency-based identification method, based on maximum-likelihood estimation, is presented, and a sensitivity analysis of the best experimental test to be considered is carried out. The procedure takes into account magnetic saturation and skin effects occurring in the windings during the frequency tests. The presented method is validated by experim...

  18. Electrooptic Methods for Measurement of Small DC Currents at High Voltage Level

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Beatty, Neville; Skilbreid, Asbjørn Ottar

    1989-01-01

    . The measuring methods can be used both for development and supervision of electrical insulating systems. For DC measurements a system wherein the voltage is applied (across the Pockels cell) not directly but via an electrooptic circuit was developed. This circuit periodically inverts the polarity of the voltage...... fibre to an electrooptic converter. Second, by use of an electronic circuit the measured signal can be converted into a modulated frequency form for transmission along an optical fibre. These systems are described, measurement results are presented and improvements to be made in the future are outlined...... across the cell, effectively applying a square wave voltage with amplitude equal to the DC voltage to be measured. The switching circuit is based around two high voltage transistors TA, TB, with the Pockels cell electrodes being each connected to one of the transistor collectors. The transistor...

  19. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne; Lava, Val

    1994-08-01

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  20. Insulation co-ordination in high-voltage electric power systems

    CERN Document Server

    Diesendorf, W

    2015-01-01

    Insulation Co-ordination in High-Voltage Electric Power Systems deals with the methods of insulation needed in different circumstances. The book covers topics such as overvoltages and lightning surges; disruptive discharge and withstand voltages; self-restoring and non-self-restoring insulation; lightning overvoltages on transmission lines; and the attenuation and distortion of lightning surges. Also covered in the book are topics such as the switching surge designs of transmission lines, as well as the insulation coordination of high-voltage stations. The text is recommended for electrical en

  1. A high-speed CMOS current op amp for very low supply voltage operation

    DEFF Research Database (Denmark)

    Bruun, Erik

    1994-01-01

    A CMOS implementation of a high-gain current mode operational amplifier (op amp) with a single-ended input and a differential output is described. This configuration is the current mode counterpart of the traditional voltage mode op amp. In order to exploit the inherent potential for high speed......, low voltage operation normally associated with current mode analog signal processing, the op amp has been designed to operate off a supply voltage of 1.5 V, and the signal path has been confined to N-channel transistors. With this design, a gain of 94 dB and a gain-bandwidth product of 65 MHz has been...

  2. Development of high voltage dc transmission at Siemens Schuckertwerke up to 1945

    Energy Technology Data Exchange (ETDEWEB)

    Bosch, M.; Schiele, O.

    1966-09-01

    High voltage dc affords advantages over three phase ac in the transmission of power over long distances and over cables, and in the coupling of three phase systems. Mercury arc rectifiers and equipment for dc voltages from 100 to 200 kV were developed and put into service in the period between 1937 and 1945. A few years ago a high voltage dc transmission group was formed by AEG, BBC and Siemens to continue the work interrupted at the end of the war.

  3. High Voltage Bidirectional Flyback Converter Driving DEAP Actuator for Automotive Applications

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.;

    2013-01-01

    DEAP (Dielectric Electro Active Polymer) is a new type of smart material. The actuator based on DEAP material tends to be applied in a variety of occasions. It will have prosperous future when employed in automotive field. This paper is focused on the design and implementation of a low input volt...... voltage and high output voltage bidirectional converter for driving the DEAP actuator. The detailed design and implemented parameters have been summarized, especially for the high voltage transformer. The experiments have been performed to validate the design and implementation....

  4. Study of Energy Losses in High-Voltage Induction Motor Electric Drive

    Directory of Open Access Journals (Sweden)

    Svilen Rachev

    2016-10-01

    Full Text Available The dynamic behavior during operation of the high-voltage induction motor electric drive has been studied by means of mathematical model developed. The purpose is to draw out more clearly picture of operation of high-voltage induction motor drives. The system of differential equations has been transformed and solved using suitable software. As a result the values of the energy losses components in the induction motor have been obtained according to different values of supply voltage and factor of inertia. Some of the study results have been presented graphically. An analysis has been made and conclusions from the results obtained have been done.

  5. HEAT TESTS OF POWER CABLES WITH XLPE INSULATION AT DIRECT VOLTAGES UP TO 110 KV

    Directory of Open Access Journals (Sweden)

    T.Yu. Antonets

    2015-12-01

    Full Text Available In this paper, experiment for determining the temperature difference between the elements of cable and in the open air is considered. The formation of a three cables laid in a plane with different spacing between adjacent cables. Tests to heat of cables for XLPE-polyethylene are used as a solid dielectric insulation. The line to XLPE-cables in group running horizontally, provided that the cables are of equal diameter and emit equal losses. It is limited to the following: the air flow around the cables may be necessary restricted by proximity to next cables. When single-core cables are installed in parallel the load current may not share equally between the parallel cables. This is because a significant proportion of the impedance of large conductors is due to self reactance and mutual reactance. Hence the spacing and relative location of each cable will have an effect on the current sharing. Calculation for each cable configuration is necessary. Possibility of using for determining the thermal properties of XLPE-cables a sheath applied over the cable surface with coefficient convection heat transfer between cable surface and the air region about it of equal zero. The work is devoted to creation of a method for calculation of the current rating of high-voltage cables in conditions function.

  6. Project resumes: biological effects from electric fields associated with high-voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)

  7. A prototype of a high-voltage platform for the KRION ion source

    Science.gov (United States)

    Alexandrov, V. S.; Donets, E. E.; Konnov, G. I.; Kosukhin, V. V.; Sidorova, V. O.; Sidorov, A. I.; Shvetsov, V. S.; Trubnikov, G. V.

    2014-09-01

    A high-voltage platform that has been developed for the KRION ion source is described. The platform design concept is explained. The calculations that have been performed of the influence of the design and materials on the source magnetic field make it possible to define a range of materials suitable for manufacturing the platform. The major components of the high-voltage platform, such as a high-voltage power supplier, and decoupling insulators of the high-voltage power source, and the main and supplementary platforms, are chosen and described. It is determined that, to exclude electric breakdowns and corona discharges, one should use an electrically shielded channel with a cryocooler and power supplies for the KRION-source coupling cables.

  8. HIGH VOLTAGE ENVIRONMENTAL APPLICATIONS, INC.ELECTRON BEAM TECHNOLOGY - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    Science.gov (United States)

    This report evaluates a high-voltage electron beam (E-beam) technology's ability to destroy volatile organic compounds (VOCs) and other contaminants present in liquid wastes. Specifically, this report discusses performance and economic data from a Superfund Innovative Technology...

  9. Circuits protection against interferences in high voltage substations; Protecao de circuitos contra interferencias em subestacoes

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Massayuki [Consultas e Aplicacoes de Engenharia Eletrica Ltda. (CAEEL) (Brazil)

    1989-12-01

    This paper makes a brief analysis of the different phenomena which may cause electromagnetic interference in high voltage substations and suggests adequate solutions to the problem according to the different events that may occur. 5 refs., 1 fig.

  10. Lithium-Ion Electrolytes with Improved Safety Tolerance to High Voltage Systems

    Science.gov (United States)

    Smart, Marshall C. (Inventor); Bugga, Ratnakumar V. (Inventor); Prakash, Surya G. (Inventor); Krause, Frederick C. (Inventor)

    2015-01-01

    The invention discloses various embodiments of electrolytes for use in lithium-ion batteries, the electrolytes having improved safety and the ability to operate with high capacity anodes and high voltage cathodes. In one embodiment there is provided an electrolyte for use in a lithium-ion battery comprising an anode and a high voltage cathode. The electrolyte has a mixture of a cyclic carbonate of ethylene carbonate (EC) or mono-fluoroethylene carbonate (FEC) co-solvent, ethyl methyl carbonate (EMC), a flame retardant additive, a lithium salt, and an electrolyte additive that improves compatibility and performance of the lithium-ion battery with a high voltage cathode. The lithium-ion battery is charged to a voltage in a range of from about 2.0 V (Volts) to about 5.0 V (Volts).

  11. FEA identification of high order generalized equivalent circuits for MF high voltage transformers

    CERN Document Server

    Candolfi, Sylvain; Cros, Jérôme; Aguglia, Davide

    2015-01-01

    This paper presents a specific methodology to derive high order generalized equivalent circuits from electromagnetic finite element analysis for high voltage medium frequency and pulse transformers by splitting the main windings in an arbitrary number of elementary windings. With this modeling approach, the dynamic model of the transformer over a large bandwidth is improved and the order of the generalized equivalent circuit can be adapted to a specified bandwidth. This efficient tool can be used by the designer to quantify the influence of the local structure of transformers on their dynamic behavior. The influence of different topologies and winding configurations is investigated. Several application examples and an experimental validation are also presented.

  12. Very Low Power, Low Voltage, High Accuracy, and High Performance Current Mirror

    Institute of Scientific and Technical Information of China (English)

    Hassan Faraji Baghtash; Khalil Monfaredi; Ahmad Ayatollahi

    2011-01-01

    A novel low power and low voltage current mirror with a very low current copy error is presented and the principle of its operation is discussed.In this circuit,the gain boosting regulated cascode scheme is used to improve the output resistance,while using inverter as an amplifier.The simulation results with HSPICE in TSMC 0.18 μm CMOS technology are given,which verify the high performance of the proposed structure.Simulation results show an input resistance of 0.014 Ω and an output resistance of 3 GΩ.The current copy error is favorable as low as 0.002% together with an input (the minimum input voltage of vin,min~ 0.24 V) and an output (the minimum output voltage of vout,min~ 0.16 V) compliances while working with the 1 V power supply and the 50 μA input current.The current copy error is near zero at the input current of 27 μA.It consumes only 76 μW and introduces a very low output offset current of 50 pA.

  13. AC Voltage Control of DC/DC Converters Based on Modular Multilevel Converters in Multi-Terminal High-Voltage Direct Current Transmission Systems

    Directory of Open Access Journals (Sweden)

    Rui Li

    2016-12-01

    Full Text Available The AC voltage control of a DC/DC converter based on the modular multilevel converter (MMC is considered under normal operation and during a local DC fault. By actively setting the AC voltage according to the two DC voltages of the DC/DC converter, the modulation index can be near unity, and the DC voltage is effectively utilized to output higher AC voltage. This significantly decreases submodule (SM capacitance and conduction losses of the DC/DC converter, yielding reduced capital cost, volume, and higher efficiency. Additionally, the AC voltage is limited in the controllable range of both the MMCs in the DC/DC converter; thus, over-modulation and uncontrolled currents are actively avoided. The AC voltage control of the DC/DC converter during local DC faults, i.e., standby operation, is also proposed, where only the MMC connected on the faulty cable is blocked, while the other MMC remains operational with zero AC voltage output. Thus, the capacitor voltages can be regulated at the rated value and the decrease of the SM capacitor voltages after the blocking of the DC/DC converter is avoided. Moreover, the fault can still be isolated as quickly as the conventional approach, where both MMCs are blocked and the DC/DC converter is not exposed to the risk of overcurrent. The proposed AC voltage control strategy is assessed in a three-terminal high-voltage direct current (HVDC system incorporating a DC/DC converter, and the simulation results confirm its feasibility.

  14. Analysis of predictor factors of limb amputation in patients with high-voltage electrical burns

    OpenAIRE

    2015-01-01

    Background: Limb amputation is considered one of the most devastating consequences of electrical injury. Any factors that correlate with the degree of muscle damage can be used to predict the necessity of limb amputation. The aim of this study was to determine the factors that can be used to predict limb amputation in high-voltage electrically injured patients. Methods: Eighty-two high-voltage electrically injured patients were admitted to the Department of Plastic and Reconstructive Surg...

  15. Review of the Dynamics of Coalescence and Demulsification by High-Voltage Pulsed Electric Fields

    OpenAIRE

    Ye Peng; Tao Liu; Haifeng Gong; Xianming Zhang

    2016-01-01

    The coalescence of droplets in oil can be implemented rapidly by high-voltage pulse electric field, which is an effective demulsification dehydration technological method. At present, it is widely believed that the main reason of pulse electric field promoting droplets coalescence is the dipole coalescence and oscillation coalescence in pulse electric field, and the optimal coalescence pulse electric field parameters exist. Around the above content, the dynamics of high-voltage pulse electric...

  16. Study of the interaction between space plasma and high voltage solar array

    OpenAIRE

    Iwasa, Minoru; TANAKA, KOJI; Sasaki, Susumu; ODAWARA, OSAMU; 岩佐 稔; 田中 孝治; 佐々木 進; 小田原 修

    2006-01-01

    We are studying the problems associated with high voltage power systems in space. Especially we are interested in the potential distribution of the solar array that is resistant to the electrical discharge. We have carried out experiment on the interaction between the space plasma and the high voltage solar array. An array of electrodes distributed on a dielectric material was used to simulate the inter-connectors of the solar array panel in space environment. One of major concerns in the usa...

  17. Study of the plasma interference with high voltage electrode array for space power application

    OpenAIRE

    Iwasa, Minoru; TANAKA, KOJI; Sasaki, Susumu; ODAWARA, OSAMU; 岩佐 稔; 田中 孝治; 佐々木 進; 小田原 修

    2005-01-01

    We are studying the problems associated with high voltage power systems in space. Especially we are interested in the potential distribution of the solar array that is resistant to the electrical discharge. We have carried out experiments on the interaction between the high voltage solar array and the ambient plasma. In the experiment, an array of electrodes distributed on the insulation panel was used to simulate the inter-connectors of the solar array. An electrode array without the insulat...

  18. Finite Element Based Optimal Design Approach for High Voltage Pulse Transformers

    CERN Document Server

    Aguglia, D; Viarouge, P; Cros, J

    2014-01-01

    This paper presents an optimal design methodology of monolithic high voltage pulse transformers based on the direct 2D FEA identification of the electrical equivalent circuit parameters. This method is applied to the preliminary optimal design of the monolithic high voltage pulse transformer for the future CLIC modulators under study at CERN. The feasibility of such a transformer with tight specifications is demonstrated. The predicted performances obtained with the direct 2D FEA optimization process is validated by 3D FEA simulation.

  19. Static Electricity as Part of Electromagnetic Environment on High-Voltage Electrical Substation

    Directory of Open Access Journals (Sweden)

    M. Fursanov

    2012-01-01

    Full Text Available Causes of occurrences electrostatic discharges (ESD on high-voltage electric substation were investigated and dependences values ESD’s on parameters interaction structures, humidity of air were found. Experimental research values ESD’s on high-voltage electric substation and in man-made conditions was fulfilled. Uncertainty measurement’s was taken into consideration by research results analyze. Matching with research of other authors was made. Danger ESD’s for electric devises was established.

  20. Self-Healable Electrical Insulation for High Voltage Applications

    Science.gov (United States)

    Williams, Tiffany S.

    2017-01-01

    Polymeric aircraft electrical insulation normally degrades by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Developing self-healing insulation could be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the insulation. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, establishment of ionic crosslinks could allow for multiple healing events to occur with the added benefit of achieving full recovery strength under certain thermal environments. This could be possible if the operating temperature of the insulator is the same as or close to the temperature where ionic crosslinks are formed. Surlyn, a commercial material with ionic crosslinks, was investigated as a candidate self-healing insulator based off prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was also studied to determine if moisture absorption rates in Surlyn were lower than that of common polyimides.

  1. 30 CFR 75.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits on high-voltage resistance grounded systems. 75.803 Section 75.803 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... High-Voltage Distribution § 75.803 Fail safe ground check circuits on high-voltage resistance...

  2. Environmental and biotechnological applications of high-voltage pulsed discharges in water

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Masayuki [Department of Chemical and Environmental Engineering, Gunma University 1-5-1 Tenjin, Kiryu, Gunma 376-8515 (Japan)], E-mail: mxsato@cee.gunma-u.ac.jp

    2008-05-01

    A high-voltage pulse has wide application in fields such as chemistry, physics and biology and their combinations. The high-voltage pulse forms two kinds of physical processes in water, namely (a) a pulsed electric field (PEF) in the parallel electrode configuration and (b) plasma generation by a pulsed discharge in the water phase with a concentrated electric field. The PEF can be used for inactivation of bacteria in liquid foods as a non-thermal process, and the underwater plasma is applicable not only for the decomposition of organic materials in water but also for biological treatment of wastewater. These discharge states are controlled mainly by the applied pulse voltage and the electrode shape. Some examples of environmental and biotechnological applications of a high-voltage pulse are reviewed.

  3. High voltage transmission lines studies with the use of artificial intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Ekonomou, L. [A.S.PE.T.E. - School of Pedagogical and Technological Education, Department of Electrical Engineering Educators, N. Heraklion, 141 21 Athens (Greece)

    2009-12-15

    The paper presents an alternative approach for the studies of high voltage transmission lines based on artificial intelligence and more specifically artificial neural networks (ANNs). In contrast to the existing conventional-analytical techniques and simulations which are using in the calculations empirical and/or approximating equations, this approach is based only on actual field data and actual measurements. The proposed approach is applied on high voltage transmission lines in order to calculate the lightning outages, on grounding systems in order to assess the grounding resistance and on high voltage transmission lines' polluted insulators in order to estimate the critical flashover voltage. The obtained results are very close to the actual ones for all three case studies, something which clearly implies that the ANN approach is well working and has an acceptable accuracy, constituting an additional tool of electric engineers. (author)

  4. The Thawing Characteristic of Frozen Tofu under High-Voltage Alternating Electric Field

    Directory of Open Access Journals (Sweden)

    Shilong Deng

    2017-01-01

    Full Text Available To systematically and comprehensively investigate the high voltage alternating electric field (HVAEF thawing processing, we investigated the high-voltage electric field thawing characteristic of the frozen tofu at different voltages for alternating current (AC. The thawing time, thawing loss of frozen tofu, and specific energy consumption (SEC of HVEF system were measured. Seven different mathematical models were then compared to simulate thawing time curves based on root mean square error, reduced mean square of deviation, and modeling efficiency. The results showed that the thawing rate of frozen tofu was notably greater in the high-voltage electric field system when compared to control. Both Linear and Quadratic models were the best mathematical models. Therefore, this work presents a facile and effective strategy for experimentally and theoretically determining the HVAEF thawing properties of frozen tofu.

  5. Design and Development of Autonomous High Voltage Driving System for DEAP Actuator in Radiator Thermostat

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.

    2014-01-01

    make a high voltage capacitive load driving system to be necessary. The only energy source battery determines it needs to be an autonomous system. The detailed system specifications have been introduced and the corresponding system level design has been proposed. In addition, the detailed design......In radiator thermostat applications, DEAP (Dielectric Electro Active Polymer) actuator tends to be a good candidate to replace the conventional self-actuating or step motor based actuator due to its intrinsic advantages. The capacitive property and high voltage (HV) driving demand of DEAP actuator...... and implementation information has been provided as well, including the power and control stage inside the high voltage converter, the output voltage measurement circuit, the feedback control, etc. Finally, the experimental results have been provided to validate the capability and performance of the driving system....

  6. The Series Connected Buck Boost Regulator Concept for High Efficiency Light Weight DC Voltage Regulation

    Science.gov (United States)

    Birchenough, Arthur G.

    2003-01-01

    Improvements in the efficiency and size of DC-DC converters have resulted from advances in components, primarily semiconductors, and improved topologies. One topology, which has shown very high potential in limited applications, is the Series Connected Boost Unit (SCBU), wherein a small DC-DC converter output is connected in series with the input bus to provide an output voltage equal to or greater than the input voltage. Since the DC-DC converter switches only a fraction of the power throughput, the overall system efficiency is very high. But this technique is limited to applications where the output is always greater than the input. The Series Connected Buck Boost Regulator (SCBBR) concept extends partial power processing technique used in the SCBU to operation when the desired output voltage is higher or lower than the input voltage, and the implementation described can even operate as a conventional buck converter to operate at very low output to input voltage ratios. This paper describes the operation and performance of an SCBBR configured as a bus voltage regulator providing 50 percent voltage regulation range, bus switching, and overload limiting, operating above 98 percent efficiency. The technique does not provide input-output isolation.

  7. Analysis of cutting-edge techniques in the high voltage and high power adjustable speed drive systems

    Institute of Scientific and Technical Information of China (English)

    ZHAO ZhengMing; BAI Hua; YUAN LiQiang

    2009-01-01

    The high voltage and high power adjustable speed drive (ASD) system is one of the most attractive fields in power electronics, and it is also a very crucial technique for energy saving and emission re-duction. This paper discussed and analyzed the main cutting-edge knowledge and issues in the proc-ess of exploiting the high voltage and high power ASD system.

  8. The 100 kV Faraday cage (High Voltage Deck) for the SPIDER experiment

    Energy Technology Data Exchange (ETDEWEB)

    Boldrin, Marco, E-mail: marco.boldrin@igi.cnr.it [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A.), Corso Stati Uniti 4, 35127 Padova (Italy); Grando, Luca; Pesce, Alberto; Recchia, Mauro; Toigo, Vanni [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A.), Corso Stati Uniti 4, 35127 Padova (Italy); Gutierrez, Daniel; Simon, Muriel [Fusion for Energy, c/o Josep Pla 2, 08019 Barcelona (Spain); Faoro, Giovanni; Guion, Andrea; Maggiora, Edoardo; Pedron, Diego [COELME – Costruzioni Elettromeccaniche S.p.A., via G. Galilei no. 1/2, 30036 S. Maria di Sala, Venezia (Italy); Roman, Anita [Studio di Ingegneria RS s.r.l., Viale dell’Arcella 1, 35153 Padova (Italy); Decamps, Hans [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2015-10-15

    Highlights: • A 100 keV experiment is under construction to optimize ITER NBI Ion Source. • The Ion Source Power Supplies are hosted inside a wide −100 kVdc Faraday cage (HVD). • The paper reports on the design solutions of the HVD. • Electrostatic and electromagnetic analyses are presented. • Procurement activities status is reported. - Abstract: In order to optimize the design and operation of the Ion Source for the ITER Neutral Beam Injector (NBI), a dedicated 100 keV Ion Source, identified as Source for the Production of Ions of Deuterium Extracted from RF plasma (SPIDER), is under construction in the Neutral Beam Test Facility, at the Consorzio RFX premises, in Padua, Italy. The Ion Source, polarized at −112 kVdc voltage, will produce negative ions (Deuterium D{sup −} or Hydrogen H{sup −}) which, extracted from the Plasma Grid with an extraction voltage up to 12 keV, are accelerated up to 100 keV by the 100 kVdc Power Supply (100 kV PS). The required Ion Source and the Extraction Power Supplies (ISEPS) system and the associated diagnostics are hosted inside a High Voltage Deck (HVD), a −100 kVdc air-insulated Faraday cage. These power supplies and various diagnostics and control equipment are connected to the Ion Source by means of a High Voltage Transmission Line (TL). The HVD (procurement started mid 2013; delivery on site in the second half of 2014) will consist of a wide structure (13 m (L) × 11 m (W) × 5 m (H)), designed to support the weight of the ISEPS components, mounted on supporting insulators and clad with a conductive metal sheet in order to reduce the electromagnetic interference (EMI). The paper reports on the design solutions of the HVD focusing on insulation, mechanical, thermal and EMI issues. The details of the main HVD interfaces with the TL and with insulating transformer are also described. Finite Element (FE) analyses have been performed, on the one hand, to verify the configuration from the electrostatic point of

  9. Testing and analysis of tube voltage and tube current in the radiation generator for mammography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hong Ryang; Hong, Dong Hee [Dept. of Health Care, Hanseo University, Seosan (Korea, Republic of); Han, Beom Hui [Dept. of Radiological Science, Seonam University, Namwon (Korea, Republic of)

    2014-03-15

    Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant , manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration 'about the safety of diagnostic radiation generator rule' specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

  10. High-voltage thin-absorber photovoltaic device structures for efficient energy harvesting

    Science.gov (United States)

    Welser, Roger E.; Pethuraja, Gopal G.; Zeller, John W.; Sood, Ashok K.; Sablon, Kimberly A.; Dhar, Nibir K.

    2014-06-01

    Efficient photovoltaic energy harvesting requires device structures capable of absorbing a wide spectrum of incident radiation and extracting the photogenerated carriers at high voltages. In this paper, we review the impact of active layer thickness on the voltage performance of GaAs-based photovoltaic device structures. We observe that thin absorber structures can be leveraged to increase the operating voltage of energy harvesting devices. Thin absorbers in combination with advanced light trapping structures provide an exciting pathway for enhancing the performance of flexible, lightweight photovoltaic modules suitable for mobile and portable power applications.

  11. High-voltage boost quasi-Z-source isolated DC/DC converter

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    A high-voltage gain two-switch quasi-Z-source isolated DC/DC converter has been presented in this study. It consists of a quasi-Z-source network at its input, a push-pull square-wave inverter at its middle, and a voltage-doubler rectifier at its output. When coordinated appropriately, the new...... converter uses less switches, a smaller common duty cycle and less turns for the transformer when compared with existing topologies. Its size and weight are therefore smaller, whereas its efficiency is higher. It is therefore well-suited for applications, where a wide range of voltage gain is required like...

  12. Modulation Voltage of High T c DC Superconducting Quantum Interference Device with Damping Resistance

    Science.gov (United States)

    Enpuku, Keiji; Doi, Hideki; Tokita, Go; Maruo, Taku

    1994-05-01

    The effect of damping resistance on the voltage versus flux (V -Φ) relation of the high T c dc superconducting quantum interference device (SQUID) is studied experimentally. Dc SQUID using YBaCuO step-edge junction and damping resistance in parallel with SQUID inductance is fabricated. Measured values of modulation voltage in the V -Φ relation are compared with those of the conventional SQUID without damping resistance. It is shown that modulation voltage is much improved by using damping resistance. The obtained experimental results agree reasonably with theoretical predictions reported previously.

  13. Voltage magnitude and margin controller for remote industrial microgrid with high wind penetration

    DEFF Research Database (Denmark)

    Cai, Yu; Lin, Jin; Song, Yonghua

    2013-01-01

    It is well known that the remote industrial microgrid is located at the periphery of the grid, which is weakly connected to the main grid. In order to enhance the voltage stability and ensure a good power quality for industries, a voltage magnitude and margin controller based on wind turbines...... is proposed in this paper. This controller includes two parts to improve voltage stability in different time scales by using local measurements. Case studies conducted for a remote microgrid with high wind penetration have proved the effectiveness of the proposed control scheme....

  14. Modeling of the CIGRE Low Voltage Test Distribution Network and the Development of Appropriate Controllers

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    controller. The control system is tested in the distribution test network set up by CIGRE. The new approach of the PV controller is done in such a way that it can control AC and DC voltage of the PV converter during dynamic conditions. The battery controller is also developed in such a way that it can...... quality issues. The main focus of this paper is on development of controllers for a distribution system with different DG’s and especially development of a Photovoltaic (PV) controller using a Static Compensator (STATCOM) controller and on modeling of a Battery Storage System (BSS) also based on a STATCOM...

  15. Analysis of a modular generator for high-voltage, high-frequency pulsed applications, using low voltage semiconductors (series connected step-up (1:10) transformers

    Science.gov (United States)

    Redondo, L. M.; Fernando Silva, J.; Margato, E.

    2007-03-01

    This article discusses the operation of a modular generator topology, which has been developed for high-frequency (kHz), high-voltage (kV) pulsed applications. The proposed generator uses individual modules, each one consisting of a pulse circuit based on a modified forward converter, which takes advantage of the required low duty cycle to operate with a low voltage clamp reset circuit for the step-up transformer. This reduces the maximum voltage on the semiconductor devices of both primary and secondary transformer sides. The secondary winding of each step-up transformer is series connected, delivering a fraction of the total voltage. Each individual pulsed module is supplied via an isolation transformer. The assembled modular laboratorial prototype, with three 5kV modules, 800V semiconductor switches, and 1:10 step-up transformers, has 80% efficiency, and is capable of delivering, into resistive loads, -15kV/1A pulses with 5μs width, 10kHz repetition rate, with less than 1μs pulse rise time. Experimental results for resistive loads are presented and discussed.

  16. Analysis of a modular generator for high-voltage, high-frequency pulsed applications, using low voltage semiconductors (series connected step-up (1:10) transformers.

    Science.gov (United States)

    Redondo, L M; Fernando Silva, J; Margato, E

    2007-03-01

    This article discusses the operation of a modular generator topology, which has been developed for high-frequency (kHz), high-voltage (kV) pulsed applications. The proposed generator uses individual modules, each one consisting of a pulse circuit based on a modified forward converter, which takes advantage of the required low duty cycle to operate with a low voltage clamp reset circuit for the step-up transformer. This reduces the maximum voltage on the semiconductor devices of both primary and secondary transformer sides. The secondary winding of each step-up transformer is series connected, delivering a fraction of the total voltage. Each individual pulsed module is supplied via an isolation transformer. The assembled modular laboratorial prototype, with three 5 kV modules, 800 V semiconductor switches, and 1:10 step-up transformers, has 80% efficiency, and is capable of delivering, into resistive loads, -15 kV1 A pulses with 5 micros width, 10 kHz repetition rate, with less than 1 micros pulse rise time. Experimental results for resistive loads are presented and discussed.

  17. Integration of offshore wind farms through high voltage direct current networks

    Science.gov (United States)

    Livermore, Luke

    The integration of offshore wind farms through Multi Terminal DC (MTDC) networks into the GB network was investigated. The ability of Voltage Source Converter (VSC) High Voltage Direct Current (HVDC) to damp Subsynchronous Resonance (SSR) and ride through onshore AC faults was studied. Due to increased levels of wind generation in Scotland, substantial onshore and offshore reinforcements to the GB transmission network are proposed. Possible inland reinforcements include the use of series compensation through fixed capacitors. This potentially can lead to SSR. Offshore reinforcements are proposed by two HVDC links. In addition to its primary functions of bulk power transmission, a HVDC link can be used to provide damping against SSR, and this function has been modelled. Simulation studies have been carried out in PSCAD. In addition, a real-time hardware-in-the-loop HVDC test rig has been used to implement and validate the proposed damping scheme on an experimental platform. When faults occur within AC onshore networks, offshore MTDC networks are vulnerable to DC overvoltages, potentially damaging the DC plant and cables. Power reduction and power dissipation control systems were investigated to ride through onshore AC faults. These methods do not require dedicated fast communication systems. Simulations and laboratory experiments are carried out to evaluate the control systems, with the results from the two platforms compared..

  18. Improved modeling of new three-phase high voltage transformer with magnetic shunts

    Directory of Open Access Journals (Sweden)

    Chraygane M.

    2015-03-01

    Full Text Available This original paper deals with a new approach for the study of behavior in nonlinear regime of a new three-phase high voltage power supply for magnetrons, used for the microwave generators in industrial applications. The design of this system is composed of a new three-phase leakage flux transformer supplying by phase a cell, composed of a capacitor and a diode, which multiplies the voltage and stabilizes the current. Each cell. in turn, supplies a single magnetron. An equivalent model of this transformer is developed taking into account the saturation phenomenon and the stabilization process of each magnetron. Each inductance of the model is characterized by a non linear relation between flux and current. This model was tested by EMTP software near the nominal state. The theoretical results were compared to experimental measurements with a good agreement. Relative to the current device, the new systemprovides gains of size, volume, cost of implementation and maintenance which make it more economical.

  19. High-voltage integrated transmitting circuit with differential driving for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Færch, Kjartan Ullitz

    2016-01-01

    In this paper, a high-voltage integrated differential transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is presented. Due to its application, area and power consumption are critical and need to be minimized. The circuitry...... is designed and implemented in AMS 0.35 μ m high-voltage process. Measurements are performed on the fabricated integrated circuit in order to assess its performance. The transmitting circuit consists of a low-voltage control logic, pulse-triggered level shifters and a differential output stage that generates...... pulses at differential voltage levels of 60, 80 and 100 V, a frequency up to 5 MHz and a measured driving strength of 2.03 V/ns with the CMUT electrical model connected. The total on-chip area occupied by the transmitting circuit is 0.18 mm2 and the power consumption at the ultrasound scanner operation...

  20. High-Precision Multi-Wave Rectifier Circuit Operating in Low Voltage + 1.5 Volt Current Mode

    Directory of Open Access Journals (Sweden)

    Bancha Burapattanasiri

    2009-12-01

    Full Text Available This article is present high-precision multi-wave rectifier circuit operating in low voltage +/- 1.5 Volt current modes by CMOS technology 0.5 μm, receive input and give output in current mode, respond at high frequency period. The structure compound with high-speed current comparator circuit, current mirror circuit, and CMOS inverter circuit. PSpice program used for confirmation the performance of testing. The PSpice program shows operating of circuit is able to working at maximum input current 400 μAp-p, maximum frequency responding 200 MHz, high precision and low power losses, and non-precision zero crossing output signal.Keywords-component; rectifier circuit; high-precision; low voltage; current mode;

  1. Extra-High-Voltage DC-DC Boost Converters Topology with Simple Control Strategy

    Directory of Open Access Journals (Sweden)

    K. Rajambal

    2009-01-01

    Full Text Available This paper presents the topology of operating DC-DC buck converter in boost mode for extra-high-voltage applications. Traditional DC-DC boost converters are used in high-voltage applications, but they are not economical due to the limited output voltage, efficiency and they require two sensors with complex control algorithm. Moreover, due to the effect of parasitic elements the output voltage and power transfer efficiency of DC-DC converters are limited. These limitations are overcome by using the voltage lift technique, opens a good way to improve the performance characteristics of DC-DC converter. The technique is applied to DC-DC converter and a simplified control algorithm in this paper. The performance of the controller is studied for both line and load disturbances. These converters perform positive DC-DC voltage increasing conversion with high power density, high efficiency, low cost in simple structure, small ripples, and wide range of control. Simulation results along theoretical analysis are provided to verify its performance.

  2. High voltage trapping effects in GaN-based metal-insulator-semiconductor transistors

    Science.gov (United States)

    Meneghesso, Gaudenzio; Meneghini, Matteo; Silvestri, Riccardo; Vanmeerbeek, Piet; Moens, Peter; Zanoni, Enrico

    2016-01-01

    This paper presents an analysis of the high voltage trapping processes that take place in high-electron mobility transistors based on GaN, with a metal-insulator-semiconductor (MIS) structure. The study is based on combined pulsed and transient measurements, carried out with trapping voltages in the range from 50 to 500 V. The results indicate that: (i) dynamic Ron is maximum for trapping voltages between 200 and 300 V, and decreases for higher voltage levels; (ii) Ron-transient measurements reveal the presence of a dominant trap with activation energy Ea1 = 0.93 eV and of a second trap with activation energy equal to Ea2 = 0.61 eV; (iii) the deep level transient spectroscopy (DLTS) signal associated to trap Ea1 is completely suppressed for high trapping voltages (VDS = 500 V). The results are interpreted by considering that the trap Ea1 is located in the buffer, and originates from CN defects. The exposure to high drain voltages may favor the depletion of such traps, due to a field-assisted de-trapping process or to the presence of vertical leakage paths.

  3. Dynamics of conductive and nonconductive particles under high-voltage electrostatic coupling fields

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    With the high-voltage electrostatic theory and numerical analysis, the dynamics of conductive and nonconductive particles under high-voltage electrostatic coupling fields was studied. The oscillation behavior of the conductive particle between the corona electrode and ground electrode was analyzed and its oscillation amplitude was Sm=(ta+ts)·νm/2. It was found that there was the "lift-off voltage (Ulo)" for the conductive particle between the electrostatic electrode and ground electrode. The concepts of "critical charged rotational speed (n?)", "detaching critical rotational speed of nonconductive particle (n′)" and "ratio of voltage and distance between surface of electrodes (U/D)" were presented and their criteria were established. The trajectories of the conductive particles under the coupling fields of the corona electrode, electrostatic electrode and ground electrode were simulated by the computer. The simulative results were in good agreement with the experimental ones. This research enriches the high-voltage electrostatic theory and provides a theoretic basis for optimization of operating parameters and structure design of high-voltage electrostatic separator.

  4. Stress-Dependent Voltage Offsets From Polymer Insulators Used in Rock Mechanics and Material Testing

    Science.gov (United States)

    Carlson, G. G.; Dahlgren, Robert; Gray, Amber; Vanderbilt, V. C.; Freund, F.; Johnston, M. J.; Dunson, C.

    2013-01-01

    Dielectric insulators are used in a variety of laboratory settings when performing experiments in rock mechanics, petrology, and electromagnetic studies of rocks in the fields of geophysics,material science, and civil engineering. These components may be used to electrically isolate geological samples from the experimental equipment, to perform a mechanical compliance function between brittle samples and the loading equipment, to match ultrasonic transducers, or perform other functions. In manyexperimental configurations the insulators bear the full brunt of force applied to the sample but do not need to withstand high voltages, therefore the insulators are often thin sheets of mechanically tough polymers. From an instrument perspective, transduction from various types of mechanical perturbation has beenqualitatively compared for a number of polymers [1, 2] and these error sources are readily apparent duringhigh-impedance measurements if not mitigated. However even when following best practices, a force dependent voltage signal still remains and its behavior is explored in this presentation. In this experimenttwo thin sheets (0.25 mm) of high-density polyethylene (HDPE) were set up in a stack, held alternatelybetween three aluminum bars; this stack was placed on the platen of a 60T capacity hydraulic testingmachine. The surface area, A, over which the force is applied to the PE sheets in this sandwich is roughly 40 square cm, each sheet forming a parallel-plate capacitor having roughly 320 pF [3], assuming therelative dielectric permittivity of PE is approximately 2.3. The outer two aluminum bars were connected to the LO input ofthe electrometer and the central aluminum bar was connected to the HI input of a Keithley model 617 electrometer. Once the stack is mechanically well-seated with no air gaps, the voltage offset is observed tobe a linear function of the baseline voltage for a given change in applied force. For a periodically appliedforce of 66.7 kN the

  5. High Voltage Hall Accelerator Propulsion System Development for NASA Science Missions

    Science.gov (United States)

    Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Shastry, Rohit; Pinero, Luis; Peterson, Todd; Dankanich, John; Mathers, Alex

    2013-01-01

    NASA Science Mission Directorates In-Space Propulsion Technology Program is sponsoring the development of a 3.8 kW-class engineering development unit Hall thruster for implementation in NASA science and exploration missions. NASA Glenn Research Center and Aerojet are developing a high fidelity high voltage Hall accelerator (HiVHAc) thruster that can achieve specific impulse magnitudes greater than 2,700 seconds and xenon throughput capability in excess of 300 kilograms. Performance, plume mappings, thermal characterization, and vibration tests of the HiVHAc engineering development unit thruster have been performed. In addition, the HiVHAc project is also pursuing the development of a power processing unit (PPU) and xenon feed system (XFS) for integration with the HiVHAc engineering development unit thruster. Colorado Power Electronics and NASA Glenn Research Center have tested a brassboard PPU for more than 1,500 hours in a vacuum environment, and a new brassboard and engineering model PPU units are under development. VACCO Industries developed a xenon flow control module which has undergone qualification testing and will be integrated with the HiVHAc thruster extended duration tests. Finally, recent mission studies have shown that the HiVHAc propulsion system has sufficient performance for four Discovery- and two New Frontiers-class NASA design reference missions.

  6. Surge current capabilities and isothermal current-voltage characteristics of high-voltage 4H-SiC junction barrier Schottky rectifiers

    Science.gov (United States)

    Palmour, J. W.; Levinshtein, M. E.; Ivanov, P. A.; Zhang, Q. J.

    2015-06-01

    Isothermal forward current-voltage characteristics of high-voltage 4H-SiC junction barrier Schottky rectifiers (JBS) have been studied for the first time. Isothermal characteristics were measured with JBS having a blocking voltage of 1700 V up to a current density j  ≈  4200 A cm-2 in the temperature range 297-460 K. Quasi-isothermal current-voltage characteristics of these devices were studied with injection of minority carriers (holes) up to j  ≈  7200 A cm-2 and ambient temperatures of 297 and 460 K. The isothermal forward current-voltage characteristics make it possible to numerically calculate (for example, by an iteration procedure) the overheating in an arbitrary operation mode.

  7. Accelerator mass spectrometer with ion selection in high-voltage terminal

    Science.gov (United States)

    Rastigeev, S. A.; Goncharov, A. D.; Klyuev, V. F.; Konstantinov, E. S.; Kutnyakova, L. A.; Parkhomchuk, V. V.; Petrozhitskii, A. V.; Frolov, A. R.

    2016-12-01

    The folded electrostatic tandem accelerator with ion selection in a high-voltage terminal is the basis of accelerator mass spectrometry (AMS) at the BINP. Additional features of the BINP AMS are the target based on magnesium vapors as a stripper without vacuum deterioration and a time-of-flight telescope with thin films for reliable ion identification. The acceleration complex demonstrates reliable operation in a mode of 1 MV with 50 Hz counting rate of 14C+3 radiocarbon for modern samples (14C/12C 1.2 × 10-12). The current state of the AMS has been considered and the experimental results of the radiocarbon concentration measurements in test samples have been presented.

  8. TCAD simulations of High-Voltage-CMOS Pixel structures for the CLIC vertex detector

    CERN Document Server

    Buckland, Matthew Daniel

    2016-01-01

    The requirements for precision physics and the experimental conditions at CLIC result in stringent constraints for the vertex detector. Capacitively coupled active pixel sensors with 25 μm pitch implemented in a commercial 180 nm High-Voltage CMOS (HV-CMOS) process are currently under study as a candidate technology for the CLIC vertex detector. Laboratory calibration measurements and beam tests with prototypes are complemented by detailed TCAD and electronic circuit simulations, aiming for a comprehensive understanding of the signal formation in the HV-CMOS sensors and subsequent readout stages. In this note 2D and 3D TCAD simulation results of the prototype sensor, the Capacitively Coupled Pixel Detector version three (CCPDv3), will be presented. These include the electric field distribution, leakage current, well capacitance, transient response to minimum ionising particles and charge-collection.

  9. The jointing stress analysis of one-shot seal-off high-voltage vacuum interrupters

    Institute of Scientific and Technical Information of China (English)

    Zhao Zhizhong; Zou Jiyan; Cong Jiyuan; Wen Huabin; Sun Hui

    2006-01-01

    The free shrinkage of ceramic or metal is restricted due to solidification of the solder. Hence the shrinkage stress arises and the jointing strength is reduced during the brazing of high-voltage vacuum interrupters ( HVVIs ) . The solder bound contour was gained by solved energy bound equation. The finite element model of weld beads was established with Surface Evolver software. Then the stress in two different cooling techniques ( natural cooling and force cooling) was calculated with ANSYS. Comparing the stress, a better cooling technique was selected for HVVIs. Its cooling time is shortened by 3 hours while the jointing stress doesn' t increase and the tensile strength of ceramic to metal seal is not decreased. The stress-rupture tests have validated the calculated results. More important, a method is found, by which the brazing technique could be improved in advance instead of blind experiments.

  10. Design and Construction of the 3.2 Mev High Voltage Column for Darht II

    CERN Document Server

    Peters, C; Yu, S; Eylon, S; Henestroza, E

    2000-01-01

    A 3.2 MeV injector has been designed and built for the Darht II Project at Los Alamos Lab. The installation of the complete injector system is nearing completion at this time. The requirements for the injector are to produce a 3.2 MeV, 2000 ampere electron pulse with a flattop width of at least 2-microseconds and emittance of less than 0.15 p cm-rad normalized. A large high voltage column has been built and installed. The column is vertically oriented, is 4.4 meters long, 1.2 meters in diameter, and weights 5700 kilograms. A novel method of construction has been employed which utilizes bonded mycalex insulating rings. This paper will describe the design, construction, and testing completed during construction. Mechanical aspects of the design will be emphasized.

  11. Fast Decoupled Power Flow for Power System with High Voltage Direct Current Transmission Line System

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2010-01-01

    Full Text Available Problem statement: High voltage direct current transmission line system has been widely applied for control power flow in power system. The power flow analysis was the one of powerful tools by which the power system equipped was analyzed both for planning and operation strategies. Approach: This study presented the method to analyze power flow of power system consisted of HVDC system. HVDC was modeled as the complex power injections. The presented complex power injected was incorporated into the existing power flow program based on fast decoupled method. The presented method was tested on the multimachine power system. Results: The transmission line loss of the system with and without HVDC was compared. Conclusion: From the simulation results, the HVDC can reduce transmission line loss of power system.

  12. Pretreatment of food waste with high voltage pulse discharge towards methane production enhancement.

    Science.gov (United States)

    Zou, Lianpei; Ma, Chaonan; Liu, Jianyong; Li, Mingfei; Ye, Min; Qian, Guangren

    2016-12-01

    Anaerobic batch tests were performed to investigate the methane production enhancement and solid transformation rates from food waste (FW) by high voltage pulse discharge (HVPD) pretreatment. The total cumulative methane production with HVPD pretreatment was 134% higher than that of the control. The final volatile solids transformation rates of FW with and without HVPD pretreatment were 54.3% and 32.3%, respectively. Comparison study on HVPD pretreatment with acid, alkali and ultrasonic pretreatments showed that the methane production and COD removal rates of FW pretreated with HVPD were more than 100% higher than the control, but only about 50% higher can be obtained with other pretreatments. HVPD pretreatment could be a promising pretreatment method in the application of energy recovery from FW.

  13. High Voltage Surface Degradation on Carbon Blacks in Lithium Ion Batteries

    DEFF Research Database (Denmark)

    Younesi, Reza

    including carbon black (CB) additives have a potential risk of degradation. Though the weight percentage of CB in commercial batteries is generally very small, the volumetric amount and thus the surface area of CB compose a rather large part of a cathode due to its small particle size (≈ 50 nm) and high......In order to increase the power density of Li-ion batteries, much research is focused on developing cathode materials that can operate at high voltages above 4.5 V with a high capacity, high cycling stability, and rate capability. However, at high voltages all the components of positive electrodes...

  14. High Voltage Surface Degradation on Carbon Blacks in Lithium Ion Batteries

    DEFF Research Database (Denmark)

    Younesi, Reza

    In order to increase the power density of Li-ion batteries, much research is focused on developing cathode materials that can operate at high voltages above 4.5 V with a high capacity, high cycling stability, and rate capability. However, at high voltages all the components of positive electrodes...... including carbon black (CB) additives have a potential risk of degradation. Though the weight percentage of CB in commercial batteries is generally very small, the volumetric amount and thus the surface area of CB compose a rather large part of a cathode due to its small particle size (≈ 50 nm) and high...

  15. Benchmarking of Voltage Sag Generators

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    The increased penetration of renewable energy systems, like photovoltaic and wind power systems, rises the concern about the power quality and stability of the utility grid. Some regulations for Low Voltage Ride-Through (LVRT) for medium voltage or high voltage applications, are coming into force...... to guide these grid-connected distributed power generation systems. In order to verify the response of such systems for voltage disturbance, mainly for evaluation of voltage sags/dips, a Voltage Sag Generator (VSG) is needed. This paper evaluates such sag test devices according to IEC 61000 in order...... to provide cheaper solutions to test against voltage sags. Simulation and experimental results demonstrate that the shunt impedance based VSG solution is the easiest and cheapest one for laboratory test applications. The back-to-back fully controlled converter based VSG is the most flexible solution...

  16. Fast response double series resonant high-voltage DC-DC converter

    Science.gov (United States)

    Lee, S. S.; Iqbal, S.; Kamarol, M.

    2012-10-01

    In this paper, a novel double series resonant high-voltage dc-dc converter with dual-mode pulse frequency modulation (PFM) control scheme is proposed. The proposed topology consists of two series resonant tanks and hence two resonant currents flow in each switching period. Moreover, it consists of two high-voltage transformer with the leakage inductances are absorbed as resonant inductor in the series resonant tanks. The secondary output of both transformers are rectified and mixed before supplying to load. In the resonant mode operation, the series resonant tanks are energized alternately by controlling two Insulated Gate Bipolar Transistor (IGBT) switches with pulse frequency modulation (PFM). This topology operates in discontinuous conduction mode (DCM) with all IGBT switches operating in zero current switching (ZCS) condition and hence no switching loss occurs. To achieve fast rise in output voltage, a dual-mode PFM control during start-up of the converter is proposed. In this operation, the inverter is started at a high switching frequency and as the output voltage reaches 90% of the target value, the switching frequency is reduced to a value which corresponds to the target output voltage. This can effectively reduce the rise time of the output voltage and prevent overshoot. Experimental results collected from a 100-W laboratory prototype are presented to verify the effectiveness of the proposed system.

  17. FPGA-based voltage and current dual drive system for high frame rate electrical impedance tomography.

    Science.gov (United States)

    Khan, Shadab; Manwaring, Preston; Borsic, Andrea; Halter, Ryan

    2015-04-01

    Electrical impedance tomography (EIT) is used to image the electrical property distribution of a tissue under test. An EIT system comprises complex hardware and software modules, which are typically designed for a specific application. Upgrading these modules is a time-consuming process, and requires rigorous testing to ensure proper functioning of new modules with the existing ones. To this end, we developed a modular and reconfigurable data acquisition (DAQ) system using National Instruments' (NI) hardware and software modules, which offer inherent compatibility over generations of hardware and software revisions. The system can be configured to use up to 32-channels. This EIT system can be used to interchangeably apply current or voltage signal, and measure the tissue response in a semi-parallel fashion. A novel signal averaging algorithm, and 512-point fast Fourier transform (FFT) computation block was implemented on the FPGA. FFT output bins were classified as signal or noise. Signal bins constitute a tissue's response to a pure or mixed tone signal. Signal bins' data can be used for traditional applications, as well as synchronous frequency-difference imaging. Noise bins were used to compute noise power on the FPGA. Noise power represents a metric of signal quality, and can be used to ensure proper tissue-electrode contact. Allocation of these computationally expensive tasks to the FPGA reduced the required bandwidth between PC, and the FPGA for high frame rate EIT. In 16-channel configuration, with a signal-averaging factor of 8, the DAQ frame rate at 100 kHz exceeded 110 frames s (-1), and signal-to-noise ratio exceeded 90 dB across the spectrum. Reciprocity error was found to be for frequencies up to 1 MHz. Static imaging experiments were performed on a high-conductivity inclusion placed in a saline filled tank; the inclusion was clearly localized in the reconstructions obtained for both absolute current and voltage mode data.

  18. High-speed, high-voltage pulse generation using avalanche transistor

    Science.gov (United States)

    Yong-sheng, Gou; Bai-yu, Liu; Yong-lin, Bai; Jun-jun, Qin; Xiao-hong, Bai; Bo, Wang; Bing-li, Zhu; Chuan-dong, Sun

    2016-05-01

    In this work, the conduction mechanism of avalanche transistors was demonstrated and the operation condition for generating high-speed pulse using avalanche transistors was illustrated. Based on the above analysis, a high-speed and high-voltage pulse (HHP) generating circuit using avalanche transistors was designed, and its working principle and process were studied. To improve the speed of the output pulse, an approach of reducing the rise time of the leading edge is proposed. Methods for selecting avalanche transistor and reducing the parasitic inductance and capacitance of printed circuit board (PCB) were demonstrated. With these instructions, a PCB with a tapered transmission line was carefully designed and manufactured. Output pulse with amplitude of 2 kV and rise time of about 200 ps was realized with this PCB mounted with avalanche transistors FMMT417, indicating the effectiveness of the HHP generating circuit design.

  19. Design of Test Circuits of DC Circuit Breaker for High Voltage Direct Current (HVDC) Distribution System-Ⅱ%高压直流输电用直流转换开关转换电流试验回路的分析与设计(2)

    Institute of Scientific and Technical Information of China (English)

    那虎; 丁正平; 孙晋峰; 杨俊清; 刘龙开; 袁方; 洪深

    2013-01-01

    For testing the high voltage direct current (HVDC) circuit breakers of HVDC distribution system in laboratory, the working conditions and characteristics of HVDC distribution system are analyzed, and two test circuits for the HVDC circuit breakers are designed according to the grid parameters and working condition requirements, as well as PSCAD simulations. The design of one of the test circuits, named direct test circuit, is described in detail and calculated.%针对超高压直流输变电系统用的直流开关转换设备的检验检测如何在试验室实施,笔者通过对直流输电系统的运行工况及特性进行研究,依据电网参数及工况的要求定性试验方法或方式.通过对转换电流开断能力试验的相关分析及PSCAD仿真试验模拟,设计了两种试验回路以满足试验参数的要求,文中介绍其中之一合成试验回路的设计及分析,并进行计算,对其实施进行了必要的阐述和探讨.

  20. 高压直流输电用直流转换开关转换电流试验回路的分析与设计(1)%Design of Test Circuits of DC Circuit Breaker for High Voltage Direct Current(HVDC) Distribution System-Ⅰ

    Institute of Scientific and Technical Information of China (English)

    那虎; 丁正平; 孙晋峰; 杨俊清; 刘龙开; 袁方; 洪深

    2012-01-01

    For testing the high voltage direct current (HVDC) circuit breakers of HVDC distribution system in laboratory, the working conditions and characteristics of HVDC distribution system are analyzed, and two test circuits for the HVDC circuit breakers are designed according to the grid parameters and working condition requirements, as well as PSCAD simulations. The design of one of the test circuits, named direct test circuit, is described in detail and calculated.%针对超高压直流输变电系统用的直流开关转换设备的检验检测如何在试验室实施,笔者通过对直流输电系统的运行工况及特性进行研究,依据电网参数及工况的要求定性试验方法或方式.通过对转换电流开断能力试验的相关分析及PSCAD仿真试验模拟,设计了两种试验回路以满足试验参数的要求,文中介绍其中之一合成试验回路的设计及分析,并进行计算,对其实施进行了必要的阐述和探讨.

  1. Job Grading Standard for Electrician (High Voltage) WG-2810.

    Science.gov (United States)

    Civil Service Commission, Washington, DC. Bureau of Policies and Standards.

    The standard covers nonsupervisory work involved in installation, test, repair, and maintenance of electric power plant and/or overhead and underground primary electrical distribution systems. These jobs require knowledge and application of electrical principles, procedures, materials, and safety standards governing work on electrical systems…

  2. Characterization of high voltage components using partial discharges; Caracterisation de composants haute tension par decharges partielles

    Energy Technology Data Exchange (ETDEWEB)

    Boucheteau, R.; Biero, H.; Prisset, C. [CEA Le Ripault, 37 - Tours (France)

    1996-12-31

    Because of the increasing size reduction of high voltage components, the classical dielectric control means do not allow to predict neither the in-service breakdown probability, nor the service life of the components even when submitted to a voltage greater to the nominal value of use. Therefore a new approach is developed which is based on the measurement of partial discharges (PD) occurring with respect to the voltage applied. PDs are due to impurities inside the materials. Pertinent parameters, such as the PDs occurrence voltage, the mean discharge current and the maximum charge of PDs are defined in order to determine a correlation between the PDs measurement and the state of the insulating material. The influence of aging is not well known. Thus the materials are submitted to more or less severe environments in order to determine the significant evolutions of PDs. (J.S.) 2 refs.

  3. Low-voltage high-speed coupling modulation in silicon racetrack ring resonators.

    Science.gov (United States)

    Yang, Rui; Zhou, Linjie; Zhu, Haike; Chen, Jianping

    2015-11-02

    We demonstrate a low-voltage high-speed modulator based on a silicon racetrack resonator with a tunable Mach-Zehnder interferometer coupler. Both static measurement and dynamic modulation experiment are carried out. The 3-dB electro-optic bandwidth is measured to be >30 GHz beyond the limit by the cavity photon lifetime. A 32 Gb/s on-off keying (OOK) modulation is realized under a peak-to-peak drive voltage as low as 0.4 V, and a 28 Gb/s binary phase-shift-keying (BPSK) modulation is realized with a drive voltage of 3 V. The low drive voltages results in low energy consumptions of ~13.3 fJ/bit and ~1.2 pJ/bit for OOK and BPSK modulations, respectively.

  4. High-voltage pulse generator with inductive energy storage and thyratron

    CERN Document Server

    Vereshchagin, N M

    2002-01-01

    The high-voltage pulse generator with the energy storage on the basis of the single layer solenoid with inductivity of 10-35 mu H is described. The TGI2-500/20 thyratron able of breaking reliably the current with the amplitude of 800-850 A was used as the current breaker. The voltage on the load is formed in two stages. The first stage is characterized by the voltage of 20-25 kV and the growth time of 150-200 m. At the second stage there takes place fast (approx 60 ns) formation of the voltage up 90 kV. The scheme of the charge quenching decreases the instability of the current breaker time

  5. The world's first high voltage GaN-on-Diamond power semiconductor devices

    Science.gov (United States)

    Baltynov, Turar; Unni, Vineet; Narayanan, E. M. Sankara

    2016-11-01

    This paper presents the detailed fabrication method and extensive electrical characterisation results of the first-ever demonstrated high voltage GaN power semiconductor devices on CVD Diamond substrate. Fabricated circular GaN-on-Diamond HEMTs with gate-to-drain drift length of 17 μm and source field plate length of 3 μm show an off-state breakdown voltage of ∼1100 V. Temperature characterisation of capacitance-voltage characteristics and on-state characteristics provides insight on the temperature dependence of key parameters such as threshold voltage, 2DEG sheet carrier concentration, specific on-state resistance, and drain saturation current in the fabricated devices.

  6. Determination of the aging offset voltage of AMR sensors based on accelerated degradation test

    NARCIS (Netherlands)

    Zambrano, Andreina; Kerkhoff, Hans G.

    2015-01-01

    Usually Anisotropic Magnetoresistance angle sensors are configured with two Wheatstone bridges, but an undesirable offset voltage included in the sensor output affects its accuracy. The total offset voltage combines a voltage due to resistance mismatches during manufacturing and a voltage from inequ

  7. Design and power management of an offshore medium voltage DC microgrid realized through high voltage power electronics technologies and control

    Science.gov (United States)

    Grainger, Brandon Michael

    The growth in the electric power industry's portfolio of Direct Current (DC) based generation and loads have captured the attention of many leading research institutions. Opportunities for using DC based systems have been explored in electric ship design and have been a proven, reliable solution for transmitting bulk power onshore and offshore. To integrate many of the renewable resources into our existing AC grid, a number of power conversions through power electronics are required to condition the equipment for direct connection. Within the power conversion stages, there is always a requirement to convert to or from DC. The AC microgrid is a conceptual solution proposed for integrating various types of renewable generation resources. The fundamental microgrid requirements include the capability of operating in islanding mode and/or grid connected modes. The technical challenges associated with microgrids include (1) operation modes and transitions that comply with IEEE1547 without extensive custom engineering and (2) control architecture and communication. The Medium Voltage DC (MVDC) architecture, explored by the University of Pittsburgh, can be visualized as a special type of DC microgrid. This dissertation is multi-faceted, focused on many design aspects of an offshore DC microgrid. The focal points of the discussion are focused on optimized high power, high frequency magnetic material performance in electric machines, transformers, and DC/DC power converters---all components found within offshore, power system architectures. A new controller design based upon model reference control is proposed and shown to stabilize the electric motor drives (modeled as constant power loads), which serve as the largest power consuming entities in the microgrid. The design and simulation of a state-of-the-art multilevel converter for High Voltage DC (HVDC) is discussed and a component sensitivity analysis on fault current peaks is explored. A power management routine is

  8. High Input Voltage Hall Thruster Discharge Converter Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall scope of this Phase I/II effort is the development of a high efficiency 15kW (nominal) Hall thruster discharge converter. In Phase I, Busek Co. Inc. will...

  9. Anomalous open-circuit voltage from a high-Tc superconducting dynamo

    Science.gov (United States)

    Bumby, C. W.; Jiang, Zhenan; Storey, J. G.; Pantoja, A. E.; Badcock, R. A.

    2016-03-01

    We report on the behavior of a high-Tc superconducting (HTS) homopolar dynamo which outputs a DC open-circuit voltage when the stator is in the superconducting state, but behaves as a conventional AC alternator when the stator is in the normal state. We observe that this time-averaged DC voltage arises from a change in the shape of the AC voltage waveform that is obtained from a normal conducting stator. The measured DC voltage is proportional to frequency, and decreases with increasing flux gap between the rotor magnet and the HTS stator wire. We observe that the DC output voltage decreases to zero at large flux gaps, although small differences between the normal-conducting and superconducting waveforms are still observed, which we attribute to screening currents in the HTS stator wire. Importantly, the normalised pulse shape is found to be a function of the rotor position angle only. Based on these observations, we suggest that the origin of this unexpected DC effect can be explained by a model first proposed by Giaever, which considers the impact of time-varying circulating eddy currents within the HTS stator wire. Such circulating currents form a superconducting shunt path which "short-circuits" the high field region directly beneath the rotor magnet, at those points in the cycle when the rotor magnet partially overlaps the superconducting stator wire. This reduces the output voltage from the device during these periods of the rotor cycle, leading to partial rectification of the output voltage waveform and hence the emergence of a time-averaged DC voltage.

  10. Speed optimized linear-mode high-voltage CMOS avalanche photodiodes with high responsivity.

    Science.gov (United States)

    Enne, R; Steindl, B; Zimmermann, H

    2015-10-01

    Two different speed optimized avalanche photodiodes (APDs) fabricated in a 0.35 μm standard high-voltage (HV) complementary metal-oxide-semiconductor (CMOS) process with a high unamplified responsivity (avalanche gain M=1) of 0.41 A/W at 670 nm are presented. These APDs differ regarding the effective doping of the deep p well (90% and 75%), using lateral well modulation doping. Compared to the -3  dB bandwidth of the unmodulated APD with 100% doping (850 MHz), this optimization leads to an improved bandwidth of 1.02 and 1.25 GHz for the 75% APD and 90% APD, respectively, both at a gain of M=50.

  11. Switch-mode High Voltage Drivers for Dielectric Electro Active Polymer (DEAP) Incremental Actuators

    DEFF Research Database (Denmark)

    Thummala, Prasanth

    , a new bidirectional flyback converter topology with multiple series connected outputs is proposed. A theoretical comparison showed that the proposed converter could improve the overall energy efficiency, lower the cost and reduce the volume of high voltage driver. Key words: high voltage, switch...... operation, and low power consumption. DEAP actuators require very high voltage (2-2.5 kV) to fully elongate them. In general, the elongation or stroke length of a DEAP actuator is of the order of mm. DEAP actuators can be configured to provide incremental motion, thus overcoming the inherent size......-to-stroke implications of conventional linear actuators, where the stroke is limited by their size. In incremental mode, DEAP actuators are several orders of magnitude shorter in their length compared to the stroke/elongation they provide. The dissertation presents design, control and implementation of switch-mode high...

  12. Serially Connected Micro Amorphous Silicon Solar Cells for Compact High-Voltage Sources

    Directory of Open Access Journals (Sweden)

    Jiyoon Nam

    2016-01-01

    Full Text Available We demonstrate a compact amorphous silicon (a-Si solar module to be used as high-voltage power supply. In comparison with the organic solar module, the main advantages of the a-Si solar module are its compatibility with photolithography techniques and relatively high power conversion efficiency. The open circuit voltage of a-Si solar cells can be easily controlled by serially interconnecting a-Si solar cells. Moreover, the a-Si solar module can be easily patterned by photolithography in any desired shapes with high areal densities. Using the photolithographic technique, we fabricate a compact a-Si solar module with noticeable photovoltaic characteristics as compared with the reported values for high-voltage power supplies.

  13. Overview of power converter designs feasible for high voltage transformer-less wind turbine

    DEFF Research Database (Denmark)

    Sztykiel, Michal

    2011-01-01

    voltage design enables low power losses and elimination of bulky step-up transformer from the wind turbine system. However, new challenges appear for such topology, which have to be properly identified and successfully overcome. This paper presents possible concept for transformer-less wind turbine......Many leading wind turbine manufacturers are pushing forward in variable-speed wind turbines, often exceeding 5 MW. Therefore, novel designs and concepts for optimal high power wind turbines appeared. One of the most promising concepts is the high voltage (10-35 kV) transformer-less topology. High...... topology along with an overview of most promising candidates for optimal full-scale power converter design. Study is carried with proposed and justified high voltage wind turbine application along with selection of existing and most promising multilevel power converter topologies, which could...

  14. Non-aqueous electrolyte for high voltage rechargeable magnesium batteries

    Science.gov (United States)

    Doe, Robert Ellis; Lane, George Hamilton; Jilek, Robert E; Hwang, Jaehee

    2015-02-10

    An electrolyte for use in electrochemical cells is provided. The properties of the electrolyte include high conductivity, high Coulombic efficiency, and an electrochemical window that can exceed 3.5 V vs. Mg/Mg.sup.+2. The use of the electrolyte promotes the electrochemical deposition and dissolution of Mg without the use of any Grignard reagents, other organometallic materials, tetraphenyl borate, or tetrachloroaluminate derived anions. Other Mg-containing electrolyte systems that are expected to be suitable for use in secondary batteries are also described.

  15. High Voltage Solar Concentrator Experiment with Implications for Future Space Missions - S6a-35

    Science.gov (United States)

    George, I. S. Mehdi P. J.; O'Neill, M.; Matson, R.; Borckschmidt, A.

    2004-12-01

    This paper describes the design, development, fabrication, and test of a high performance, high voltage solar concentrator array. This assembly is believed to be the first ever terrestrial triple-junction-cell solar array rated at over 1 kW. The concentrator provides over 200 W/square meter power output at a nominal 600 Vdc while operating under terrestrial sunlight. Space-quality materials and fabrication techniques were used for the array, and the 3005-meter elevation installation below the Tropic of Cancer allowed testing as close as possible to space deployment without an actual launch. The array includes two concentrator modules, each with a 3 square meter aperture area. Each concentrator module uses a linear Fresnel lens to focus sunlight onto a photovoltaic receiver that uses 240 series-connected triple-junction solar cells. Operation of the two receivers in series can provide 1200 Vdc which would be adequate for the "direct drive" of some ion engines or microwave transmitters in space. Lens aperture width is 84 cm and the cell active width is 3.2 cm, corresponding to a geometric concentration ratio of 26X. The evaluation includes the concentrator modules, the solar cells, and the materials and techniques used to attach the solar cells to the receiver heat sink. For terrestrial applications, a finned aluminum extrusion was used for the heat sink for the solar cells, maintaining a low cell temperature so that solar cell efficiency remains high.

  16. The design, construction, and operation of long-distance high-voltage electricity transmission technologies.

    Energy Technology Data Exchange (ETDEWEB)

    Molburg, J. C.; Kavicky, J. A.; Picel, K. C.

    2008-03-03

    This report focuses on transmission lines, which operate at voltages of 115 kV and higher. Currently, the highest voltage lines comprising the North American power grid are at 765 kV. The grid is the network of transmission lines that interconnect most large power plants on the North American continent. One transmission line at this high voltage was built near Chicago as part of the interconnection for three large nuclear power plants southwest of the city. Lines at this voltage also serve markets in New York and New England, also very high demand regions. The large power transfers along the West Coast are generally at 230 or 500 kV. Just as there are practical limits to centralization of power production, there are practical limits to increasing line voltage. As voltage increases, the height of the supporting towers, the size of the insulators, the distance between conductors on a tower, and even the width of the right-of-way (ROW) required increase. These design features safely isolate the electric power, which has an increasing tendency to arc to ground as the voltage (or electrical potential) increases. In addition, very high voltages (345 kV and above) are subject to corona losses. These losses are a result of ionization of the atmosphere, and can amount to several megawatts of wasted power. Furthermore, they are a local nuisance to radio transmission and can produce a noticeable hum. Centralized power production has advantages of economies of scale and special resource availability (for instance, hydro resources), but centralized power requires long-distance transfers of power both to reach customers and to provide interconnections for reliability. Long distances are most economically served at high voltages, which require large-scale equipment and impose a substantial footprint on the corridors through which power passes. The most visible components of the transmission system are the conductors that provide paths for the power and the towers that keep these

  17. High-voltage electrode optimization towards uniform surface treatment by a pulsed volume discharge

    Science.gov (United States)

    Ponomarev, A. V.; Pedos, M. S.; Scherbinin, S. V.; Mamontov, Y. I.; Ponomarev, S. V.

    2015-11-01

    In this study, the shape and material of the high-voltage electrode of an atmospheric pressure plasma generation system were optimised. The research was performed with the goal of achieving maximum uniformity of plasma treatment of the surface of the low-voltage electrode with a diameter of 100 mm. In order to generate low-temperature plasma with the volume of roughly 1 cubic decimetre, a pulsed volume discharge was used initiated with a corona discharge. The uniformity of the plasma in the region of the low-voltage electrode was assessed using a system for measuring the distribution of discharge current density. The system's low-voltage electrode - collector - was a disc of 100 mm in diameter, the conducting surface of which was divided into 64 radially located segments of equal surface area. The current at each segment was registered by a high-speed measuring system controlled by an ARM™-based 32-bit microcontroller. To facilitate the interpretation of results obtained, a computer program was developed to visualise the results. The program provides a 3D image of the current density distribution on the surface of the low-voltage electrode. Based on the results obtained an optimum shape for a high-voltage electrode was determined. Uniformity of the distribution of discharge current density in relation to distance between electrodes was studied. It was proven that the level of non-uniformity of current density distribution depends on the size of the gap between electrodes. Experiments indicated that it is advantageous to use graphite felt VGN-6 (Russian abbreviation) as the material of the high-voltage electrode's emitting surface.

  18. Consideration and research of high voltage insulation strategy for ITER Feeder busbar joint

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiongyi [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Song, Yuntao, E-mail: songyt@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Zheng, Jinxing; Yu, Xiaowu; Xiao, Weiwu; Gao, Daming; Tao, Yuming; Wang, Chunyu [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Gung, Chen-yu; Clayton, Nicholas [ITER IO, Tokamak Department, Magnet Division, 13067 St. Paul lez Durance (France); Niu, Erwu [China International Nuclear Fusion Energy Program Execution, Beijing 100086 (China); Chen, Yonghua; Mitcell, Neil [ITER IO, Tokamak Department, Magnet Division, 13067 St. Paul lez Durance (France)

    2013-10-15

    Highlights: • Several rounds insulation trials for ITER Feeder joint were carried out in ASIPP. • Wet-winding, VPI were practiced and attempt for the best impregnation strategy. • Improvement of wet-winding technology with vacuum assistance was realized. • To supplement the electrical test, DR technology was explored for insulation quality inspection. -- Abstract: The ITER Feeder busbar joint is an important component which connects different sections of busbar which run from the high temperature superconducting current leads to the magnet terminals. High voltage insulated bus bar sections will be assembled onto the feeder support structure (called the containment duct), and the joints between sections will be made in situ. The high voltage insulation over the joint is the final step to complete the insulation of the whole bus bar system, and its quality is key to achieving the required electrical performance of the system. The final joint has a complex external configuration with an irregular structure in places, which makes it difficult for the application of the insulation. The limited access in the Feeder and the complex joint external structure make the implementation of the joint insulation hard to solve. The Feeder group at ASIPP has carried out significant R and D for the joint insulation, involving research on the selection of materials, the design of the insulation structure, the curing technology and the quality inspection method. After many rounds of manufacturing and testing, the insulation strategy for the Feeder joint will focus on the so-called “wet-winding” technology. Despite the fact that this process has some intrinsic disadvantages, it is more appropriate for the joint structure compared to other methods. The sub-suppliers to ASIPP have chosen this impregnation method for the feeder qualification activities based on guidance from ASIPP. This paper describes the research procedure of the ITER Feeder busbar joint insulation

  19. A threshold voltage model for high-κgate-dielectric MOSFETs considering fringing-field effect

    Institute of Scientific and Technical Information of China (English)

    Ji Feng; Xu Jing-Ping; Lai Pui-To

    2007-01-01

    In this paper, a threshold voltage model for high-κgate-dielectric metal-oxide-semiconductor field-effect transistors (MOSFETs) is developed, with more accurate boundary conditions of the gate dielectric derived through a conformal mapping transformation method to consider the fringing-field effects including the influences of high-κgate-dielectric and sidewall spacer. Comparing with similar models, the proposed model can be applied to general situations where the gate dielectric and sidewall spacer can have different dielectric constants. The influences of sidewall spacer and high-κgate dielectric on fringing field distribution of the gate dielectric and thus threshold voltage behaviours of a MOSFET are discussed in detail.

  20. High frequency capacitor-diode voltage multiplier dc-dc converter development

    Science.gov (United States)

    Kisch, J. J.; Martinelli, R. M.

    1977-01-01

    A power conditioner was developed which used a capacitor diode voltage multiplier to provide a high voltage without the use of a step-up transformer. The power conditioner delivered 1200 Vdc at 100 watts and was operated from a 120 Vdc line. The efficiency was in excess of 90 percent. The component weight was 197 grams. A modified boost-add circuit was used for the regulation. A short circuit protection circuit was used which turns off the drive circuit upon a fault condition, and recovers within 5 ms after removal of the short. High energy density polysulfone capacitors and high speed diodes were used in the multiplier circuit.