WorldWideScience

Sample records for high temporal contrast

  1. Generation of 25-TW Femtosecond Laser Pulses at 515 nm with Extremely High Temporal Contrast

    Directory of Open Access Journals (Sweden)

    Marco Hornung

    2015-12-01

    Full Text Available We report on the frequency doubling of femtosecond laser pulses at 1030 nm center wavelength generated from the fully diode-pumped laser system POLARIS. The newly generated pulses at a center wavelength of 515 nm have a pulse energy of 3 J with a pulse duration of 120 fs. On the basis of initially ultra-high contrast seed pulses we expect a temporal intensity contrast better 10 17 200 ps before the peak of the main pulse. We analyzed the temporal intensity contrast from milliseconds to femtoseconds with a dynamic range covering more than 20 orders of magnitude. The pulses were focussed with a f/2-focussing parabola resulting in a peak intensity exceeding 10 20 W / cm 2 . The peak power and intensity are to the best of our knowledge the highest values for 515 nm-laser-pulses achieved so far.

  2. Laser-matter interaction at high intensity and high temporal contrast; Interaction laser matiere a haut flux et fort contraste temporel

    Energy Technology Data Exchange (ETDEWEB)

    Doumy, G

    2006-01-15

    The continuous progress in the development of laser installations has already lead to ultra-short pulses capable of achieving very high focalized intensities (I > 10{sup 18} W/cm{sup 2}). At these intensities, matter presents new non-linear behaviours, due to the fact that the electrons are accelerated to relativistic speeds. The experimental access to this interaction regime on solid targets has long been forbidden because of the presence, alongside the femtosecond pulse, of a pedestal (mainly due to the amplified spontaneous emission (ASE) which occurs in the laser chain) intense enough to modify the state of the target. In this thesis, we first characterized, both experimentally and theoretically, a device which allows an improvement of the temporal contrast of the pulse: the Plasma Mirror. It consists in adjusting the focusing of the pulse on a dielectric target, so that the pedestal is mainly transmitted, while the main pulse is reflected by the overcritical plasma that it forms at the surface. The implementation of such a device on the UHI 10 laser facility (CEA Saclay - 10 TW - 60 fs) then allowed us to study the interaction between ultra-intense, high contrast pulses with solid targets. In a first part, we managed to generate and characterize dense plasmas resulting directly from the interaction between the main pulse and very thin foils (100 nm). This characterization was realized by using an XUV source obtained by high order harmonics generation in a rare gas jet. In a second part, we studied experimentally the phenomenon of high order harmonics generation on solid targets, which is still badly understood, but could potentially lead to a new kind of energetic ultra-short XUV sources. (author)

  3. Assessment of cardiac time intervals using high temporal resolution real-time spiral phase contrast with UNFOLDed-SENSE.

    Science.gov (United States)

    Kowalik, Grzegorz T; Knight, Daniel S; Steeden, Jennifer A; Tann, Oliver; Odille, Freddy; Atkinson, David; Taylor, Andrew; Muthurangu, Vivek

    2015-02-01

    To develop a real-time phase contrast MR sequence with high enough temporal resolution to assess cardiac time intervals. The sequence utilized spiral trajectories with an acquisition strategy that allowed a combination of temporal encoding (Unaliasing by fourier-encoding the overlaps using the temporal dimension; UNFOLD) and parallel imaging (Sensitivity encoding; SENSE) to be used (UNFOLDed-SENSE). An in silico experiment was performed to determine the optimum UNFOLD filter. In vitro experiments were carried out to validate the accuracy of time intervals calculation and peak mean velocity quantification. In addition, 15 healthy volunteers were imaged with the new sequence, and cardiac time intervals were compared to reference standard Doppler echocardiography measures. For comparison, in silico, in vitro, and in vivo experiments were also carried out using sliding window reconstructions. The in vitro experiments demonstrated good agreement between real-time spiral UNFOLDed-SENSE phase contrast MR and the reference standard measurements of velocity and time intervals. The protocol was successfully performed in all volunteers. Subsequent measurement of time intervals produced values in keeping with literature values and good agreement with the gold standard echocardiography. Importantly, the proposed UNFOLDed-SENSE sequence outperformed the sliding window reconstructions. Cardiac time intervals can be successfully assessed with UNFOLDed-SENSE real-time spiral phase contrast. Real-time MR assessment of cardiac time intervals may be beneficial in assessment of patients with cardiac conditions such as diastolic dysfunction. © 2014 Wiley Periodicals, Inc.

  4. Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI.

    Directory of Open Access Journals (Sweden)

    Laurent Bonnemains

    Full Text Available During paediatric cardiac Cine-MRI, data acquired during cycles of different lengths must be combined. Most of the time, Feinstein's model is used to project multiple cardiac cycles of variable lengths into a mean cycle.To assess the effect of Feinstein projection on temporal resolution of Cine-MRI.1/The temporal errors during Feinstein's projection were computed in 306 cardiac cycles fully characterized by tissue Doppler imaging with 6-phase analysis (from a population of 7 children and young adults. 2/The effects of these temporal errors on tissue velocities were assessed by simulating typical tissue phase mapping acquisitions and reconstructions. 3/Myocardial velocities curves, extracted from high-resolution phase-contrast cine images, were compared for the 6 volunteers with lowest and highest heart rate variability, within a population of 36 young adults.1/The mean of temporal misalignments was 30 ms over the cardiac cycle but reached 60 ms during early diastole. 2/During phase contrast MRI simulation, early diastole velocity peaks were diminished by 6.1 cm/s leading to virtual disappearance of isovolumic relaxation peaks. 3/The smoothing and erasing of isovolumic relaxation peaks was confirmed on tissue phase mapping velocity curves, between subjects with low and high heart rate variability (p = 0.05.Feinstein cardiac model creates temporal misalignments that impair high temporal resolution phase contrast cine imaging when beat-to-beat heart rate is changing.

  5. High-Spatial- and High-Temporal-Resolution Dynamic Contrast-enhanced MR Breast Imaging with Sweep Imaging with Fourier Transformation: A Pilot Study

    Science.gov (United States)

    Benson, John C.; Idiyatullin, Djaudat; Snyder, Angela L.; Snyder, Carl J.; Hutter, Diane; Everson, Lenore I.; Eberly, Lynn E.; Nelson, Michael T.; Garwood, Michael

    2015-01-01

    Purpose To report the results of sweep imaging with Fourier transformation (SWIFT) magnetic resonance (MR) imaging for diagnostic breast imaging. Materials and Methods Informed consent was obtained from all participants under one of two institutional review board–approved, HIPAA-compliant protocols. Twelve female patients (age range, 19–54 years; mean age, 41.2 years) and eight normal control subjects (age range, 22–56 years; mean age, 43.2 years) enrolled and completed the study from January 28, 2011, to March 5, 2013. Patients had previous lesions that were Breast Imaging Reporting and Data System 4 and 5 based on mammography and/or ultrasonographic imaging. Contrast-enhanced SWIFT imaging was completed by using a 4-T research MR imaging system. Noncontrast studies were completed in the normal control subjects. One of two sized single-breast SWIFT-compatible transceiver coils was used for nine patients and five controls. Three patients and five control subjects used a SWIFT-compatible dual breast coil. Temporal resolution was 5.9–7.5 seconds. Spatial resolution was 1.00 mm isotropic, with later examinations at 0.67 mm isotropic, and dual breast at 1.00 mm or 0.75 mm isotropic resolution. Results Two nonblinded breast radiologists reported SWIFT image findings of normal breast tissue, benign fibroadenomas (six of six lesions), and malignant lesions (10 of 12 lesions) concordant with other imaging modalities and pathologic reports. Two lesions in two patients were not visualized because of coil field of view. The images yielded by SWIFT showed the presence and extent of known breast lesions. Conclusion The SWIFT technique could become an important addition to breast imaging modalities because it provides high spatial resolution at all points during the dynamic contrast-enhanced examination. © RSNA, 2014 PMID:25247405

  6. Multiecho pseudo-golden angle stack of stars thermometry with high spatial and temporal resolution using k-space weighted image contrast.

    Science.gov (United States)

    Svedin, Bryant T; Payne, Allison; Bolster, Bradley D; Parker, Dennis L

    2017-06-22

    Implement and evaluate a 3D MRI method to measure temperature changes with high spatial and temporal resolution and large field of view. A multiecho pseudo-golden angle stack-of-stars (SOS) sequence with k-space weighted image contrast (KWIC) reconstruction was implemented to simultaneously measure multiple quantities, including temperature, initial signal magnitude M(0), transverse relaxation time ( T2*), and water/fat images. Respiration artifacts were corrected using self-navigation. KWIC artifacts were removed using a multi-baseline library. The phases of the multiple echo images were combined to improve proton resonance frequency precision. Temperature precision was tested through in vivo breast imaging (N = 5 healthy volunteers) using both coronal and sagittal orientations and with focused ultrasound (FUS) heating in a pork phantom using a breast specific MR-guided FUS system. Temperature measurement precision was significantly improved after echo combination when compared with the no echo combination case (spatial average of the standard deviation through time of 0.3-1.0 and 0.7-1.9°C, respectively). Temperature measurement accuracy during heating was comparable to a 3D seg-EPI sequence. M(0) and T2* values showed temperature dependence during heating in pork adipose tissue. A self-navigated 3D multiecho SOS sequence with dynamic KWIC reconstruction is a promising thermometry method that provides multiple temperature sensitive quantitative values. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  7. Generation of ultra-intense and ultra-short laser pulses with high temporal contrast; Generation d'impulsions laser ultra-breves et ultra-intenses a contraste temporel eleve

    Energy Technology Data Exchange (ETDEWEB)

    Julien, A

    2006-03-15

    The topic of this thesis work concerns the design and the characterization of an efficient device devoted to the temporal contrast improvement for ultra-intense femtosecond laser pulses. The contrast is defined as the intensity ratio between the main femtosecond pulse and its nanosecond pedestal. This pedestal is the amplified spontaneous emission (ASE), inherent with laser amplification mechanism. The ASE background has dramatic effects for laser-matter interactions on a solid target. The presented work consists in the theoretical and experimental study of a temporal filter based on a third order nonlinear effect acting on the pulse polarization. We have studied several kinds of nonlinear filters. The selected device is based on the process of cross-polarized wave generation (XPW) in crystals with an anisotropic third-order nonlinear susceptibility. This nonlinear filter has been experimented on various femtosecond systems. It allows a contrast improvement of several orders of magnitude, as demonstrated by temporal profiles measurements on a large intensity dynamic. A device to improve the nonlinear process conversion efficiency, it means the filter transmission, has also been achieved. This method is based on constructive interferences between XPW signals generated in different crystals. This setup has made it possible to reach experimentally the maximum theoretical efficiency ( >20%) and in the same time ensures the system stability. At least, we have demonstrated that the filter preserves, or even improves, spectral and spatial qualities of the laser pulse. These results are thus particularly promising and allow contemplating the implementation of the filter in current femtosecond systems. (author)

  8. Temporal adaptation enhances efficient contrast gain control on natural images.

    Directory of Open Access Journals (Sweden)

    Fabian Sinz

    Full Text Available Divisive normalization in primary visual cortex has been linked to adaptation to natural image statistics in accordance to Barlow's redundancy reduction hypothesis. Using recent advances in natural image modeling, we show that the previously studied static model of divisive normalization is rather inefficient in reducing local contrast correlations, but that a simple temporal contrast adaptation mechanism of the half-saturation constant can substantially increase its efficiency. Our findings reveal the experimentally observed temporal dynamics of divisive normalization to be critical for redundancy reduction.

  9. Associations Between Spatial and Temporal Contrast Sensitivity and Reading

    NARCIS (Netherlands)

    Brussee, Tamara; van den Berg, Thomas J T P; van Nispen, Ruth M A; van Rens, Ger H M B

    2017-01-01

    PURPOSE: To gain insight into the association between optical and neural components of contrast sensitivity (CS), operationalized as spatial CS (optical and neural) or temporal CS (solely neural), and reading speed in a clinical sample of healthy adults of various ages. Furthermore, precision and

  10. Temporal subtraction contrast-enhanced dedicated breast CT

    Science.gov (United States)

    Gazi, Peymon M.; Aminololama-Shakeri, Shadi; Yang, Kai; Boone, John M.

    2016-09-01

    The development of a framework of deformable image registration and segmentation for the purpose of temporal subtraction contrast-enhanced breast CT is described. An iterative histogram-based two-means clustering method was used for the segmentation. Dedicated breast CT images were segmented into background (air), adipose, fibroglandular and skin components. Fibroglandular tissue was classified as either normal or contrast-enhanced then divided into tiers for the purpose of categorizing degrees of contrast enhancement. A variant of the Demons deformable registration algorithm, intensity difference adaptive Demons (IDAD), was developed to correct for the large deformation forces that stemmed from contrast enhancement. In this application, the accuracy of the proposed method was evaluated in both mathematically-simulated and physically-acquired phantom images. Clinical usage and accuracy of the temporal subtraction framework was demonstrated using contrast-enhanced breast CT datasets from five patients. Registration performance was quantified using normalized cross correlation (NCC), symmetric uncertainty coefficient, normalized mutual information (NMI), mean square error (MSE) and target registration error (TRE). The proposed method outperformed conventional affine and other Demons variations in contrast enhanced breast CT image registration. In simulation studies, IDAD exhibited improvement in MSE (0-16%), NCC (0-6%), NMI (0-13%) and TRE (0-34%) compared to the conventional Demons approaches, depending on the size and intensity of the enhancing lesion. As lesion size and contrast enhancement levels increased, so did the improvement. The drop in the correlation between the pre- and post-contrast images for the largest enhancement levels in phantom studies is less than 1.2% (150 Hounsfield units). Registration error, measured by TRE, shows only submillimeter mismatches between the concordant anatomical target points in all patient studies. The algorithm was

  11. A new technique for quantifying temporal envelope contrasts.

    Science.gov (United States)

    Fortune, T W; Woodruff, B D; Preves, D A

    1994-02-01

    A new technique has been developed for precisely quantifying the temporal contrasts that exist between two sound samples. This technique is based on envelope subtraction, and generates an Envelope Difference Index that may be used to help clarify whether alteration of the natural speech envelope via amplification improves or degrades speech intelligibility. The Envelope Difference Index method may also be used to assess hearing aid saturation, and may have other applications as well. The technique is applicable whenever a precise quantification of the difference between two temporal envelopes is required, regardless of stimulus duration.

  12. Associations Between Spatial and Temporal Contrast Sensitivity and Reading.

    Science.gov (United States)

    Brussee, Tamara; van den Berg, Thomas J T P; van Nispen, Ruth M A; van Rens, Ger H M B

    2017-03-01

    To gain insight into the association between optical and neural components of contrast sensitivity (CS), operationalized as spatial CS (optical and neural) or temporal CS (solely neural), and reading speed in a clinical sample of healthy adults of various ages. Furthermore, precision and agreement of the two methods were assessed. The Mars test and the temporal CS implementation of the C-Quant device were used to measure spatial CS and temporal CS, respectively. Tests were performed with 71 normally sighted adults: mean age 55 (range 18-86) years. Pearson's correlation analyses were performed between spatial CS or temporal CS, and reading speed and partial correlations controlled for age are presented. Precision of the measurement was defined by the coefficient of repeatability and repeated measures standard deviations. Differences between spatial CS and temporal CS values were determined with 95% limits of agreement. A correlation was found between reading speed and both spatial CS (r = 0.470; P reading speed indicating that, besides optical components, neural aspects may be important in defining reading speed. The stronger correlation between spatial CS and reading speed is suggested to reflect a deterioration of both optical and neural factors with increasing age. The coefficients of repeatability for spatial CS and temporal CS found in the present study are in agreement with previous research, and the difference found between the two methods might be attributed to the psychometric differences between the methods.

  13. Spatial and Temporal Control of Cavitation Allows High In Vitro Transfection Efficiency in the Absence of Transfection Reagents or Contrast Agents.

    Science.gov (United States)

    Chettab, Kamel; Roux, Stéphanie; Mathé, Doriane; Cros-Perrial, Emeline; Lafond, Maxime; Lafon, Cyril; Dumontet, Charles; Mestas, Jean-Louis

    2015-01-01

    Sonoporation using low-frequency high-pressure ultrasound (US) is a non-viral approach for in vitro and in vivo gene delivery. In this study, we developed a new sonoporation device designed for spatial and temporal control of ultrasound cavitation. The regulation system incorporated in the device allowed a real-time control of the cavitation level during sonoporation. This device was evaluated for the in vitro transfection efficiency of a plasmid coding for Green Fluorescent Protein (pEGFP-C1) in adherent and non-adherent cell lines. The transfection efficiency of the device was compared to those observed with lipofection and nucleofection methods. In both adherent and non-adherent cell lines, the sonoporation device allowed high rate of transfection of pEGFP-C1 (40-80%), as determined by flow cytometry analysis of GFP expression, along with a low rate of mortality assessed by propidium iodide staining. The transfection efficiency and toxicity of sonoporation on the non-adherent cell lines Jurkat and K562 were similar to those of nucleofection, while these two cell lines were resistant to transfection by lipofection. Moreover, sonoporation was used to produce three stably transfected human lymphoma and leukemia lines. Significant transfection efficiency was also observed in two fresh samples of human acute myeloid leukemia cells. In conclusion, we developed a user-friendly and cost-effective ultrasound device, well adapted for routine in vitro high-yield transfection experiments and which does not require the use of any transfection reagent or gas micro-bubbles.

  14. Offset analgesia: a temporal contrast mechanism for nociceptive information.

    Science.gov (United States)

    Yelle, Marc D; Rogers, June M; Coghill, Robert C

    2008-01-01

    Temporal filtering of afferent information is an intrinsic component of the processing of numerous types of sensory information. To date, no temporal filtering mechanism has been identified for nociceptive information. The phenomenon of offset analgesia, the disproportionately large decrease in perceived pain following slight decreases in noxious thermal intensity, however, suggests the existence of such a mechanism. To test the hypothesis that a temporal filtering mechanism is engaged during noxious stimulus offset, subjects rated heat pain intensity while stimulus fall rates were varied from -0.5 to -5.0 degrees C/s. In the absence of a temporal filtering mechanism, pain intensity would be expected to decrease in direct proportion to the stimulus fall rate. However, psychophysical fall rates were considerably faster than stimulus fall rates, such that subjects reported no pain while stimulus temperatures were clearly within the noxious range (47.2 degrees C). In addition, paired noxious stimuli were presented simultaneously to determine if offset analgesia evoked by one stimulus could inhibit pain arising from a separate population of primary afferent neurons. Pain ratings were significantly lower than those reported from two constant 49 degrees C stimuli when offset analgesia was induced proximal to, but not distal to, a second noxious stimulus. These asymmetric spatial interactions are not readily explained by peripheral mechanisms. Taken together, these findings indicate that offset analgesia is mediated in part by central mechanisms and reflect a temporal filtering of the sensory information that enhances the contrast of dynamic decreases in noxious stimulus intensity.

  15. High-contrast imaging testbed

    Energy Technology Data Exchange (ETDEWEB)

    Baker, K; Silva, D; Poyneer, L; Macintosh, B; Bauman, B; Palmer, D; Remington, T; Delgadillo-Lariz, M

    2008-01-23

    Several high-contrast imaging systems are currently under construction to enable the detection of extra-solar planets. In order for these systems to achieve their objectives, however, there is considerable developmental work and testing which must take place. Given the need to perform these tests, a spatially-filtered Shack-Hartmann adaptive optics system has been assembled to evaluate new algorithms and hardware configurations which will be implemented in these future high-contrast imaging systems. In this article, construction and phase measurements of a membrane 'woofer' mirror are presented. In addition, results from closed-loop operation of the assembled testbed with static phase plates are presented. The testbed is currently being upgraded to enable operation at speeds approaching 500 hz and to enable studies of the interactions between the woofer and tweeter deformable mirrors.

  16. High index contrast photonics platform

    Science.gov (United States)

    Chu, Sai T.; Little, Brent E.; Hryniewicz, John V.; Johnson, Fred G.; King, Oliver; Gill, Dave; Chen, Wenlu; Chen, Wei

    2005-10-01

    A new low-loss high-index-contrast photonics platform has been developed for integrated optics and microwave photonics. The platform consists of a material system that has an index contrast that is adjustable from 0 to 25% and which is processed using conventional CMOS tools. The platform allows one to four orders of magnitude reduction in the size of optical components compared with conventional planar technologies. As an example, meter long path lengths occupy coils that are millimeters in diameter. Microwave photonic building blocks that are enabled include large bit count programmable delay lines for beam steering and shaping that fit in less than a square centimeter and which have delays controllable from 5 fsec to 10 nsec. Also enabled are arrays of high order tunable filters, a hundred micrometers in size, having linewidths ranging from tens of MHz to tens of GHz. These filters can be tuned over several hundred GHz, and when placed in Vernier architectures can be tuned across the C band (5 THz). An optical chip typically consists of dozens of optical elements. Each element is placed in its own micro-control loop that consists of a thin film heater for thermo-optic control and a thermistor for electronic feedback. The micro-control loops impart intelligence to the optical chip.

  17. Electrophysiological measures of temporal resolution, contrast sensitivity and spatial resolving power in sharks.

    Science.gov (United States)

    Ryan, Laura A; Hemmi, Jan M; Collin, Shaun P; Hart, Nathan S

    2017-03-01

    In most animals, vision plays an important role in detecting prey, predators and conspecifics. The effectiveness of vision in assessing cues such as motion and shape is influenced by the ability of the visual system to detect changes in contrast in both space and time. Understanding the role vision plays in shark behaviour has been limited by a lack of knowledge about their temporal resolution, contrast sensitivity and spatial resolution. In this study, an electrophysiological approach was used to compare these measures across five species of sharks: Chiloscyllium punctatum, Heterodontus portusjacksoni, Hemiscyllium ocellatum, Mustelus mustelus and Haploblepharus edwardsii. All shark species were highly sensitive to brightness contrast and were able to detect contrast differences as low as 1.6%. Temporal resolution of flickering stimuli ranged from 28 to 44 Hz. Species that inhabit brighter environments were found to have higher temporal resolution. Spatial resolving power was estimated in C. punctatum, H. portusjacksoni and H. ocellatum and ranged from 0.10 to 0.35 cycles per degree, which is relatively low compared to other vertebrates. These results suggest that sharks have retinal adaptations that enhance contrast sensitivity at the expense of temporal and spatial resolution, which is beneficial for vision in dimly lit and/or low contrast aquatic environments.

  18. High temporal and spatial resolution 3D time-resolved contrast-enhanced magnetic resonance angiography of the hands and feet.

    Science.gov (United States)

    Haider, Clifton R; Riederer, Stephen J; Borisch, Eric A; Glockner, James F; Grimm, Roger C; Hulshizer, Thomas C; Macedo, Thanila A; Mostardi, Petrice M; Rossman, Phillip J; Vrtiska, Terri J; Young, Phillip M

    2011-07-01

    Methods are described for generating 3D time-resolved contrast-enhanced magnetic resonance (MR) angiograms of the hands and feet. Given targeted spatial resolution and frame times, it is shown that acceleration of about one order of magnitude or more is necessary. This is obtained by a combination of 2D sensitivity encoding (SENSE) and homodyne (HD) acceleration methods. Image update times from 3.4-6.8 seconds are provided in conjunction with view sharing. Modular receiver coil arrays are described which can be designed to the targeted vascular region. Images representative of the technique are generated in the vasculature of the hands and feet in volunteers and in patient studies. Copyright © 2011 Wiley-Liss, Inc.

  19. Generation And Measurement Of High Contrast Ultrashort Intense Laser Pulses

    CERN Document Server

    Konoplev, O A

    2000-01-01

    In this thesis, the generation and measurement of high contrast, intense, ultrashort pulses have been studied. Various factors affecting the contrast and pulse shape of ultrashort light pulses from a chirped pulse amplification (CPA) laser system are identified. The level of contrast resulting from influence of these factors is estimated. Methods for improving and controlling the pulse shape and increasing the contrast are discussed. Ultrahigh contrast, 1-ps pulses were generated from a CPA system with no temporal structure up to eleven orders of magnitude. This is eight orders of magnitude higher contrast than the original pulse. This contrast boost was achieved using two techniques. One is the optical pulse cleaning based on the nonlinear birefringence of the chirping fiber and applied to the pulses before amplification. The other is the fast saturable absorber. The fast saturable absorber was placed after amplification and compression of the pulse. The measurements of high-contrast, ultrashort pulse with h...

  20. Adding temporally localized noise can enhance the contribution of target knowledge on contrast detection.

    Science.gov (United States)

    Silvestre, Daphné; Cavanagh, Patrick; Arleo, Angelo; Allard, Rémy

    2017-02-01

    External noise paradigms are widely used to characterize sensitivity by comparing the effect of a variable on contrast threshold when it is limited by internal versus external noise. A basic assumption of external noise paradigms is that the processing properties are the same in low and high noise. However, recent studies (e.g., Allard & Cavanagh, 2011; Allard & Faubert, 2014b) suggest that this assumption could be violated when using spatiotemporally localized noise (i.e., appearing simultaneously and at the same location as the target) but not when using spatiotemporally extended noise (i.e., continuously displayed, full-screen, dynamic noise). These previous findings may have been specific to the crowding and 0D noise paradigms that were used, so the purpose of the current study is to test if this violation of noise-invariant processing also occurs in a standard contrast detection task in white noise. The rationale of the current study is that local external noise triggers the use of recognition rather than detection and that a recognition process should be more affected by uncertainty about the shape of the target than one involving detection. To investigate the contribution of target knowledge on contrast detection, the effect of orientation uncertainty was evaluated for a contrast detection task in the absence of noise and in the presence of spatiotemporally localized or extended noise. A larger orientation uncertainty effect was observed with temporally localized noise than with temporally extended noise or with no external noise, indicating a change in the nature of the processing for temporally localized noise. We conclude that the use of temporally localized noise in external noise paradigms risks triggering a shift in process, invalidating the noise-invariant processing required for the paradigm. If, instead, temporally extended external noise is used to match the properties of internal noise, no such processing change occurs.

  1. Talk of change: Temporal contrasts and collective identities

    NARCIS (Netherlands)

    Ybema, S.B.

    2010-01-01

    While temporality is generally acknowledged as a critical ingredient in processes of identity formation, studies of identity talk usually assume collective identity is essentially about establishing or facilitating a sense of temporal self-continuity. These studies do not detail how organizational

  2. Transmission grating stretcher for contrast enhancement of high power lasers.

    Science.gov (United States)

    Tang, Yunxin; Hooker, Chris; Chekhlov, Oleg; Hawkes, Steve; Collier, John; Rajeev, P P

    2014-12-01

    We propose, for the first time, a transmission grating stretcher for high power lasers and demonstrate its superiority over conventional, reflective gold grating stretchers in terms of pulse temporal quality. We show that, compared to a conventional stretcher with the same stretching factor, the transmission-grating based stretcher yields more than an order of magnitude improvement in the contrast pedestal. We have also quantitatively characterized the roughness of the grating surfaces and estimated its impact on the contrast pedestal.

  3. Temporal clauses with conditional value in legal language (contrastive study

    Directory of Open Access Journals (Sweden)

    Iva Svobodová

    2017-12-01

    Full Text Available This study is a summary of a qualitative and quantitative linguistic investigation of the Portuguese and Brazilian Penal Code, and contains important results pertaining to the temporal clauses introduced by the connector quando. We focused on its semantic conditional features, suggesting the name pseudo-temporal clauses for these hypotactic constructions and observe the relation between the occurrence of different verbal modes and the semantic interpretation. We verify, in both the texts, the temporal clauses introduced by quando have an evident conditional value. On the other side, the compared texts are different regarding the selection of the verbal mode. The Portuguese Penal Code preferred, evidently, the subjunctive mode and in the Brazilian one the indicative mode. We explained this divergence by semantic and pragmatic factors.

  4. Contrasting temporal trend discovery for large healthcare databases.

    Science.gov (United States)

    Hrovat, Goran; Stiglic, Gregor; Kokol, Peter; Ojsteršek, Milan

    2014-01-01

    With the increased acceptance of electronic health records, we can observe the increasing interest in the application of data mining approaches within this field. This study introduces a novel approach for exploring and comparing temporal trends within different in-patient subgroups, which is based on associated rule mining using Apriori algorithm and linear model-based recursive partitioning. The Nationwide Inpatient Sample (NIS), Healthcare Cost and Utilization Project (HCUP), Agency for Healthcare Research and Quality was used to evaluate the proposed approach. This study presents a novel approach where visual analytics on big data is used for trend discovery in form of a regression tree with scatter plots in the leaves of the tree. The trend lines are used for directly comparing linear trends within a specified time frame. Our results demonstrate the existence of opposite trends in relation to age and sex based subgroups that would be impossible to discover using traditional trend-tracking techniques. Such an approach can be employed regarding decision support applications for policy makers when organizing campaigns or by hospital management for observing trends that cannot be directly discovered using traditional analytical techniques. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. NASA High Contrast Imaging for Exoplanets

    Science.gov (United States)

    Lyon, Richard G.

    2008-01-01

    Described is NASA's ongoing program for the detection and characterization of exosolar planets via high-contrast imaging. Some of the more promising proposed techniques under assessment may enable detection of life outside our solar system. In visible light terrestrial planets are approximately 10(exp -10) dimmer than the parent star. Issues such as diffraction, scatter, wavefront, amplitude and polarization all contribute to a reduction in contrast. An overview of the techniques will be discussed.

  6. Homogenization of High-Contrast Brinkman Flows

    KAUST Repository

    Brown, Donald L.

    2015-04-16

    Modeling porous flow in complex media is a challenging problem. Not only is the problem inherently multiscale but, due to high contrast in permeability values, flow velocities may differ greatly throughout the medium. To avoid complicated interface conditions, the Brinkman model is often used for such flows [O. Iliev, R. Lazarov, and J. Willems, Multiscale Model. Simul., 9 (2011), pp. 1350--1372]. Instead of permeability variations and contrast being contained in the geometric media structure, this information is contained in a highly varying and high-contrast coefficient. In this work, we present two main contributions. First, we develop a novel homogenization procedure for the high-contrast Brinkman equations by constructing correctors and carefully estimating the residuals. Understanding the relationship between scales and contrast values is critical to obtaining useful estimates. Therefore, standard convergence-based homogenization techniques [G. A. Chechkin, A. L. Piatniski, and A. S. Shamev, Homogenization: Methods and Applications, Transl. Math. Monogr. 234, American Mathematical Society, Providence, RI, 2007, G. Allaire, SIAM J. Math. Anal., 23 (1992), pp. 1482--1518], although a powerful tool, are not applicable here. Our second point is that the Brinkman equations, in certain scaling regimes, are invariant under homogenization. Unlike in the case of Stokes-to-Darcy homogenization [D. Brown, P. Popov, and Y. Efendiev, GEM Int. J. Geomath., 2 (2011), pp. 281--305, E. Marusic-Paloka and A. Mikelic, Boll. Un. Mat. Ital. A (7), 10 (1996), pp. 661--671], the results presented here under certain velocity regimes yield a Brinkman-to-Brinkman upscaling that allows using a single software platform to compute on both microscales and macroscales. In this paper, we discuss the homogenized Brinkman equations. We derive auxiliary cell problems to build correctors and calculate effective coefficients for certain velocity regimes. Due to the boundary effects, we construct

  7. Temporal variability in taxonomic and trait compositions of invertebrate assemblages in two climatic regions with contrasting flow regimes.

    Science.gov (United States)

    Dolédec, Sylvain; Tilbian, Jessica; Bonada, Núria

    2017-12-01

    Understanding natural temporal changes in Mediterranean rivers with contrasting flow regimes in relation to those of temperate rivers may prove helpful in predicting effects of climate change on aquatic biodiversity. We aimed to compare temporal variability in taxonomic and trait compositions of nearly natural rivers in two climatic regions with varying flow regimes to address the effects of future climate changes on aquatic biodiversity in reference conditions. We analysed taxonomic and biological trait compositions using the Foucard multivariate method to compare within-site temporal variability levels and the evolution of within-date spatial variability patterns. In addition, we assessed the effects of temporal variability levels on taxonomic and functional diversity and on community specialization. Our results reveal (i) highly fluctuating environments of the Mediterranean region, particularly in intermittent rivers, which lead to higher levels of temporal variability in both taxonomic and trait compositions of benthic invertebrate assemblages, with marked synchrony in Mediterranean streams linked to contrasting flow characteristics; (ii) higher degrees of taxonomic richness associated with higher levels of functional diversity in Mediterranean rivers relative to temperate rivers, (iii) higher temporal stability for functional diversity and trait compositions of benthic invertebrate assemblages than for taxonomic richness and compositions; and (iv) a recovery of all diversity metrics following drying events in intermittent sites. This study offers insight into a rarely addressed question concerning the temporal variability of trait compositions in benthic invertebrate assemblages among rivers differing in terms of flow regimes. It suggests that temperate rivers will experience higher levels of temporal variability in terms of taxonomic and trait compositions under future climatic change scenarios, even in sites that will remain perennial, resulting in higher

  8. High-index-contrast subwavelength grating VCSEL

    DEFF Research Database (Denmark)

    Gilet, Philippe; Olivier, Nicolas; Grosse, Philippe

    2010-01-01

    In this article, we report our results on 980nm high-index-contrast subwavelength grating (HCG) VCSELs for optical interconnection applications. In our structure, a thin undoped HCG layer replaces a thick p-type Bragg mirror. The HCG mirror can feasibly achieve polarization-selective reflectivities...... structures. These results build a bridge between a standard VCSEL and a hybrid laser on silicon, making them of potential use for the realization of silicon photonics....

  9. 1550 nm high contrast grating VCSEL.

    Science.gov (United States)

    Chase, Christopher; Rao, Yi; Hofmann, Werner; Chang-Hasnain, Connie J

    2010-07-19

    We demonstrate an electrically pumped high contrast grating (HCG) VCSEL operating at 1550 nm incorporating a proton implant-defined aperture. Output powers of >1 mW are obtained at room temperature under continuous wave operation. Devices operate continuous wave at temperatures exceeding 60 degrees C. The novel device design, which is grown in a single epitaxy step, may enable lower cost long wavelength VCSELs.

  10. First Bloch eigenvalue in high contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Briane, Marc, E-mail: mbriane@insa-rennes.fr [Institut de Recherche Mathématique de Rennes, INSA de Rennes (France); Vanninathan, Muthusamy, E-mail: vanni@math.tifrbng.res.in [TIFR-CAM, Bangalore (India)

    2014-01-15

    This paper deals with the asymptotic behavior of the first Bloch eigenvalue in a heterogeneous medium with a high contrast εY-periodic conductivity. When the conductivity is bounded in L{sup 1} and the constant of the Poincaré-Wirtinger weighted by the conductivity is very small with respect to ε{sup −2}, the first Bloch eigenvalue converges as ε → 0 to a limit which preserves the second-order expansion with respect to the Bloch parameter. In dimension two the expansion of the limit can be improved until the fourth-order under the same hypotheses. On the contrary, in dimension three a fibers reinforced medium combined with a L{sup 1}-unbounded conductivity leads us to a discontinuity of the limit first Bloch eigenvalue as the Bloch parameter tends to zero but remains not orthogonal to the direction of the fibers. Therefore, the high contrast conductivity of the microstructure induces an anomalous effect, since for a given low-contrast conductivity the first Bloch eigenvalue is known to be analytic with respect to the Bloch parameter around zero.

  11. Distortions of temporal integration and perceived order caused by the interplay between stimulus contrast and duration

    NARCIS (Netherlands)

    Akyürek, Elkan G.; de Jong, Ritske

    2017-01-01

    Stimulus contrast and duration effects on visual temporal integration and order judgment were examined in a unified paradigm. Stimulus onset asynchrony was governed by the duration of the first stimulus in Experiment 1, and by the interstimulus interval in Experiment 2. In Experiment 1, integration

  12. Halftoning for high-contrast imaging

    Directory of Open Access Journals (Sweden)

    Kasper M.

    2011-07-01

    Full Text Available High-contrast instruments, such as SPHERE (upcoming planet finder instrument for the ESO-VLT, or EPICS (planet hunter project for the future E-ELT, will require customized components with spatially varying transmission (e.g. coronagraphs, optical components that reduce the contrast between a companion and its parent star. The goal of these sub-systems is to control the spatial transmission, either in a pupil plane (pupil apodization, or in a focal plane of the instrument (occulting mask, i.e. low-frequency filter. Reliably producing components with spatially varying transmission is not trivial, and different techniques have been already investigated for application to astronomy (e.g. metal deposition with spatially-varying thickness, or high-energy beam sensitive glass using e-beam lithography. We present some results related to the recent development of components with spatially varying transmission using a relatively simple technique analogous to the digital halftoning process used for printing applications.

  13. Integration of spatio-temporal contrast sensitivity with a multi-slice channelized Hotelling observer

    Science.gov (United States)

    Avanaki, Ali N.; Espig, Kathryn S.; Marchessoux, Cedric; Krupinski, Elizabeth A.; Bakic, Predrag R.; Kimpe, Tom R. L.; Maidment, Andrew D. A.

    2013-03-01

    Barten's model of spatio-temporal contrast sensitivity function of human visual system is embedded in a multi-slice channelized Hotelling observer. This is done by 3D filtering of the stack of images with the spatio-temporal contrast sensitivity function and feeding the result (i.e., the perceived image stack) to the multi-slice channelized Hotelling observer. The proposed procedure of considering spatio-temporal contrast sensitivity function is generic in the sense that it can be used with observers other than multi-slice channelized Hotelling observer. Detection performance of the new observer in digital breast tomosynthesis is measured in a variety of browsing speeds, at two spatial sampling rates, using computer simulations. Our results show a peak in detection performance in mid browsing speeds. We compare our results to those of a human observer study reported earlier (I. Diaz et al. SPIE MI 2011). The effects of display luminance, contrast and spatial sampling rate, with and without considering foveal vision, are also studied. Reported simulations are conducted with real digital breast tomosynthesis image stacks, as well as stacks from an anthropomorphic software breast phantom (P. Bakic et al. Med Phys. 2011). Lesion cases are simulated by inserting single micro-calcifications or masses. Limitations of our methods and ways to improve them are discussed.

  14. High-contrast and fast electrochromic switching enabled by plasmonics

    Science.gov (United States)

    Talin, Albert; Xu, Ting; Walter, Erich; Agrawal, Amit; Bohn, Christopher; Velmurugan, Jeyavel; Zhu, Wenqi; Lezec, Henri

    With vibrant colors and simple, room-temperature processing methods, electrochromic polymers have long attracted attention as active materials for flexible, low-power consuming devices such as smart windows and displays. However, despite their many advantages, slow switching speed and complexity of combining several separate polymers to achieve full-color gamut has limited electrochromic materials to niche applications. Here we exploit the enhanced light-matter interaction associated with the deep-subwavelength mode confinement of surface plasmon polaritons propagating in metallic nanoslit arrays coated with ultra-thin electrochromic polymers to build a novel configuration for achieving high-contrast and fast electrochromic switching. The switchable configuration retains the short temporal charge-diffusion characteristics of thin electrochromic films while maintaining the high optical-contrast associated with thicker electrochromic coatings. We further demonstrate that by controlling the pitch of the nanoslit arrays, it is possible to achieve a full-color response with high-contrast and fast switching-speeds while relying on just one electrochromic polymer.

  15. Contrasting Effects of Vocabulary Knowledge on Temporal and Parietal Brain Structure across Lifespan

    Science.gov (United States)

    Richardson, Fiona M.; Thomas, Michael S. C.; Filippi, Roberto; Harth, Helen; Price, Cathy J.

    2010-01-01

    Using behavioral, structural, and functional imaging techniques, we demonstrate contrasting effects of vocabulary knowledge on temporal and parietal brain structure in 47 healthy volunteers who ranged in age from 7 to 73 years. In the left posterior supramarginal gyrus, vocabulary knowledge was positively correlated with gray matter density in teenagers but not adults. This region was not activated during auditory or visual sentence processing, and activation was unrelated to vocabulary skills. Its gray matter density may reflect the use of an explicit learning strategy that links new words to lexical or conceptual equivalents, as used in formal education and second language acquisition. By contrast, in left posterior temporal regions, gray matter as well as auditory and visual sentence activation correlated with vocabulary knowledge throughout lifespan. We propose that these effects reflect the acquisition of vocabulary through context, when new words are learnt within the context of semantically and syntactically related words. PMID:19366285

  16. Contrasting effects of vocabulary knowledge on temporal and parietal brain structure across lifespan.

    Science.gov (United States)

    Richardson, Fiona M; Thomas, Michael S C; Filippi, Roberto; Harth, Helen; Price, Cathy J

    2010-05-01

    Using behavioral, structural, and functional imaging techniques, we demonstrate contrasting effects of vocabulary knowledge on temporal and parietal brain structure in 47 healthy volunteers who ranged in age from 7 to 73 years. In the left posterior supramarginal gyrus, vocabulary knowledge was positively correlated with gray matter density in teenagers but not adults. This region was not activated during auditory or visual sentence processing, and activation was unrelated to vocabulary skills. Its gray matter density may reflect the use of an explicit learning strategy that links new words to lexical or conceptual equivalents, as used in formal education and second language acquisition. By contrast, in left posterior temporal regions, gray matter as well as auditory and visual sentence activation correlated with vocabulary knowledge throughout lifespan. We propose that these effects reflect the acquisition of vocabulary through context, when new words are learnt within the context of semantically and syntactically related words.

  17. The advantage of high relaxivity contrast agents in brain perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Cotton, F. [MRI Center, Centre Hospitalier Lyon Sud, Pierre Benite (France); CREATIS, INSA-502, Villeurbanne (France); Lab. d' Anatomie, UFR Laennec, Lyon (France); Hermier, M. [CREATIS, INSA-502, Villeurbanne (France); MRI Center, Neurologic Hospital, Lyon (France)

    2006-01-10

    Accurate MRI characterization of brain lesions is critical for planning therapeutic strategy, assessing prognosis and monitoring response to therapy. Conventional MRI with gadolinium-based contrast agents is useful for the evaluation of brain lesions, but this approach primarily depicts areas of disruption of the blood-brain barrier (BBB) rather than tissue perfusion. Advanced MR imaging techniques such as dynamic contrast agent-enhanced perfusion MRI provide physiological information that complements the anatomic data available from conventional MRI. We evaluated brain perfusion imaging with gadobenate dimeglumine (Gd-BOPTA, MultiHance; Bracco Imaging, Milan, Italy). The contrast-enhanced perfusion technique was performed on a Philips Intera 1.5-T MR system. The technique used to obtain perfusion images was dynamic susceptibility contrast-enhanced MRI, which is highly sensitive to T2* changes. Combined with PRESTO perfusion imaging, SENSE is applied to double the temporal resolution, thereby improving the signal intensity curve fit and, accordingly, the accuracy of the derived parametric images. MultiHance is the first gadolinium MR contrast agent with significantly higher T1 and T2 relaxivities than conventional MR contrast agents. The higher T1 relaxivity, and therefore better contrast-enhanced T1-weighted imaging, leads to significantly improved detection of BBB breakdown and hence improved brain tumor conspicuity and delineation. The higher T2 relaxivity allows high-quality T2*-weighted perfusion MRI and the derivation of good quality relative cerebral blood volume (rCBV) maps. We determined the value of MultiHance for enhanced T2*-weighted perfusion imaging of histologically proven (by surgery or stereotaxic biopsy) intraaxial brain tumors (n=80), multiple sclerosis lesions (n=10), abscesses (n=4), neurolupus (n=15) and stroke (n=16). All the procedures carried out were safe and no adverse events occurred. The acquired perfusion images were of good quality in

  18. Temporal Dynamics of Soil Microbial Communities below the Seedbed under Two Contrasting Tillage Regimes

    Directory of Open Access Journals (Sweden)

    Florine Degrune

    2017-06-01

    Full Text Available Agricultural productivity relies on a wide range of ecosystem services provided by the soil biota. Plowing is a fundamental component of conventional farming, but long-term detrimental effects such as soil erosion and loss of soil organic matter have been recognized. Moving towards more sustainable management practices such as reduced tillage or crop residue retention can reduce these detrimental effects, but will also influence structure and function of the soil microbiota with direct consequences for the associated ecosystem services. Although there is increasing evidence that different tillage regimes alter the soil microbiome, we have a limited understanding of the temporal dynamics of these effects. Here, we used high-throughput sequencing of bacterial and fungal ribosomal markers to explore changes in soil microbial community structure under two contrasting tillage regimes (conventional and reduced tillage either with or without crop residue retention. Soil samples were collected over the growing season of two crops (Vicia faba and Triticum aestivum below the seedbed (15–20 cm. Tillage, crop and growing stage were significant determinants of microbial community structure, but the impact of tillage showed only moderate temporal dependency. Whereas the tillage effect on soil bacteria showed some temporal dependency and became less strong at later growing stages, the tillage effect on soil fungi was more consistent over time. Crop residue retention had only a minor influence on the community. Six years after the conversion from conventional to reduced tillage, soil moisture contents and nutrient levels were significantly lower under reduced than under conventional tillage. These changes in edaphic properties were related to specific shifts in microbial community structure. Notably, bacterial groups featuring copiotrophic lifestyles or potentially carrying the ability to degrade more recalcitrant compounds were favored under conventional

  19. Temporal Dynamics of Soil Microbial Communities below the Seedbed under Two Contrasting Tillage Regimes.

    Science.gov (United States)

    Degrune, Florine; Theodorakopoulos, Nicolas; Colinet, Gilles; Hiel, Marie-Pierre; Bodson, Bernard; Taminiau, Bernard; Daube, Georges; Vandenbol, Micheline; Hartmann, Martin

    2017-01-01

    Agricultural productivity relies on a wide range of ecosystem services provided by the soil biota. Plowing is a fundamental component of conventional farming, but long-term detrimental effects such as soil erosion and loss of soil organic matter have been recognized. Moving towards more sustainable management practices such as reduced tillage or crop residue retention can reduce these detrimental effects, but will also influence structure and function of the soil microbiota with direct consequences for the associated ecosystem services. Although there is increasing evidence that different tillage regimes alter the soil microbiome, we have a limited understanding of the temporal dynamics of these effects. Here, we used high-throughput sequencing of bacterial and fungal ribosomal markers to explore changes in soil microbial community structure under two contrasting tillage regimes (conventional and reduced tillage) either with or without crop residue retention. Soil samples were collected over the growing season of two crops ( Vicia faba and Triticum aestivum ) below the seedbed (15-20 cm). Tillage, crop and growing stage were significant determinants of microbial community structure, but the impact of tillage showed only moderate temporal dependency. Whereas the tillage effect on soil bacteria showed some temporal dependency and became less strong at later growing stages, the tillage effect on soil fungi was more consistent over time. Crop residue retention had only a minor influence on the community. Six years after the conversion from conventional to reduced tillage, soil moisture contents and nutrient levels were significantly lower under reduced than under conventional tillage. These changes in edaphic properties were related to specific shifts in microbial community structure. Notably, bacterial groups featuring copiotrophic lifestyles or potentially carrying the ability to degrade more recalcitrant compounds were favored under conventional tillage, whereas

  20. High Framerate Imaging of Ultrasound Contrast Agents

    OpenAIRE

    Viti, Jacopo

    2016-01-01

    markdownabstractUltrasound contrast agents (UCAs) consists of a suspension of tiny gas bubbles that is injected into a patient's bloodstream to enhance the visualization of blood in ultrasound images. As UCAs respond differently to ultrasound pulses compared to the surrounding soft tissues and blood, it is possible to employ specialized techniques to identify and isolate UCAs in an ultrasound image. This is commonly referred to as Ultrasound Contrast Imaging. This PhD thesis evaluates several...

  1. Measuring sparse temporal-variation for accurate registration of dynamic contrast-enhanced breast MR images.

    Science.gov (United States)

    Zheng, Yuanjie; Wei, Benzheng; Liu, Hui; Xiao, Rui; Gee, James C

    2015-12-01

    Accurate registration of dynamic contrast-enhanced (DCE) MR breast images is challenging due to the temporal variations of image intensity and the non-rigidity of breast motion. The former can cause the well-known tumor shrinking/expanding problem in registration process while the latter complicates the task by requiring an estimation of non-rigid deformation. In this paper, we treat the intensity's temporal variations as "corruptions" which spatially distribute in a sparse pattern and model them with a L1 norm and a Lorentzian norm. We show that these new image similarity measurements can characterize the non-Gaussian property of the difference between the pre-contrast and post-contrast images and help to resolve the shrinking/expanding problem by forgiving significant image variations. Furthermore, we propose an iteratively re-weighted least squares based method and a linear programming based technique for optimizing the objective functions obtained using these two novel norms. We show that these optimization techniques outperform the traditional gradient-descent approach. Experimental results with sequential DCE-MR images from 28 patients show the superior performances of our algorithms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Dendrimers as high relaxivity MR contrast agents.

    Science.gov (United States)

    Longmire, Michelle R; Ogawa, Mikako; Choyke, Peter L; Kobayashi, Hisataka

    2014-01-01

    Dendrimers are versatile macromolecules with tremendous potential as magnetic resonance imaging (MRI) contrast agents. Dendrimer-based agents provide distinct advantages over low-molecular-weight gadolinium chelates, including enhanced r1 relaxivity due to slow rotational dynamics, tunable pharmacokinetics that can be adapted for blood pool, liver, kidney, and lymphatic imaging, the ability to be a drug carrier, and flexibility for labeling due to their inherent multivalency. Clinical applications are increasingly being developed, particularly in lymphatic imaging. Herein we present a broad overview of dendrimer-based MRI contrast agents with attention to the unique chemistry and physical properties as well as emerging clinical applications. © 2013 Wiley Periodicals, Inc.

  3. High Framerate Imaging of Ultrasound Contrast Agents

    NARCIS (Netherlands)

    J. Viti (Jacopo)

    2016-01-01

    markdownabstractUltrasound contrast agents (UCAs) consists of a suspension of tiny gas bubbles that is injected into a patient's bloodstream to enhance the visualization of blood in ultrasound images. As UCAs respond differently to ultrasound pulses compared to the surrounding soft tissues and

  4. Carrier-envelope-phase stable, high-contrast, double chirped-pulse-amplification laser system.

    Science.gov (United States)

    Jullien, Aurélie; Ricci, Aurélien; Böhle, Frederik; Rousseau, Jean-Philippe; Grabielle, Stéphanie; Forget, Nicolas; Jacqmin, Hermance; Mercier, Brigitte; Lopez-Martens, Rodrigo

    2014-07-01

    We present the first carrier-envelope-phase stable chirped-pulse amplifier (CPA) featuring high temporal contrast for relativistic intensity laser-plasma interactions at 1 kHz repetition rate. The laser is based on a double-CPA architecture including cross-polarized wave (XPW) filtering technique and a high-energy grism-based compressor. The 8 mJ, 22 fs pulses feature 10⁻¹¹ temporal contrast at -20  ps and a carrier-envelope-phase drift of 240 mrad root mean square.

  5. Stability of Temporal Contrasts across Speaking Styles in English and Croatian.

    Science.gov (United States)

    Smiljanic, Rajka; Bradlow, Ann R

    2008-01-01

    In this paper we investigate the effect of clear speech, a distinct, listener-oriented, intelligibility-enhancing mode of speech production, on vowel and stop consonant contrasts along the temporal dimension in English and Croatian. Our previous work has shown that, in addition to enhancing the overall acoustic salience of the speech signal through a decrease in speaking rate and expansion of pitch range, clear speech modifications increased the spectral distances between vowel categories in both languages despite the different sizes of their vowel inventories (+10 in English, 5 in Croatian). Here, we examine how clear speech affects the duration of English tense ('long') vs. lax ('short') vowels, English vowels preceding voiced ('long') vs. voiceless ('short') coda stops, Croatian long vs. short vowels and Croatian and English VOT duration for voiced and voiceless stops. Overall, the results showed that the proportional distance between the 'short' and 'long' vowel categories and between the voiced and voiceless stop categories was remarkably stable across the two speaking styles in both languages. These results suggest that, in combination with the spectral enhancement of vowel contrasts, language-specific pronunciation norms along the temporal dimension are maintained in clear and conversational speech.

  6. Quantitative Evaluation of Temporal Regularizers in Compressed Sensing Dynamic Contrast Enhanced MRI of the Breast

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2017-01-01

    Full Text Available Purpose. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI is used in cancer imaging to probe tumor vascular properties. Compressed sensing (CS theory makes it possible to recover MR images from randomly undersampled k-space data using nonlinear recovery schemes. The purpose of this paper is to quantitatively evaluate common temporal sparsity-promoting regularizers for CS DCE-MRI of the breast. Methods. We considered five ubiquitous temporal regularizers on 4.5x retrospectively undersampled Cartesian in vivo breast DCE-MRI data: Fourier transform (FT, Haar wavelet transform (WT, total variation (TV, second-order total generalized variation (TGVα2, and nuclear norm (NN. We measured the signal-to-error ratio (SER of the reconstructed images, the error in tumor mean, and concordance correlation coefficients (CCCs of the derived pharmacokinetic parameters Ktrans (volume transfer constant and ve (extravascular-extracellular volume fraction across a population of random sampling schemes. Results. NN produced the lowest image error (SER: 29.1, while TV/TGVα2 produced the most accurate Ktrans (CCC: 0.974/0.974 and ve (CCC: 0.916/0.917. WT produced the highest image error (SER: 21.8, while FT produced the least accurate Ktrans (CCC: 0.842 and ve (CCC: 0.799. Conclusion. TV/TGVα2 should be used as temporal constraints for CS DCE-MRI of the breast.

  7. Quantitative Evaluation of Temporal Regularizers in Compressed Sensing Dynamic Contrast Enhanced MRI of the Breast.

    Science.gov (United States)

    Wang, Dong; Arlinghaus, Lori R; Yankeelov, Thomas E; Yang, Xiaoping; Smith, David S

    2017-01-01

    Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is used in cancer imaging to probe tumor vascular properties. Compressed sensing (CS) theory makes it possible to recover MR images from randomly undersampled k-space data using nonlinear recovery schemes. The purpose of this paper is to quantitatively evaluate common temporal sparsity-promoting regularizers for CS DCE-MRI of the breast. We considered five ubiquitous temporal regularizers on 4.5x retrospectively undersampled Cartesian in vivo breast DCE-MRI data: Fourier transform (FT), Haar wavelet transform (WT), total variation (TV), second-order total generalized variation (TGV α(2)), and nuclear norm (NN). We measured the signal-to-error ratio (SER) of the reconstructed images, the error in tumor mean, and concordance correlation coefficients (CCCs) of the derived pharmacokinetic parameters K(trans) (volume transfer constant) and ve (extravascular-extracellular volume fraction) across a population of random sampling schemes. NN produced the lowest image error (SER: 29.1), while TV/TGV α(2) produced the most accurate K(trans) (CCC: 0.974/0.974) and ve (CCC: 0.916/0.917). WT produced the highest image error (SER: 21.8), while FT produced the least accurate K(trans) (CCC: 0.842) and ve (CCC: 0.799). TV/TGV α(2) should be used as temporal constraints for CS DCE-MRI of the breast.

  8. Contrasting spatial and temporal responses of bird communities to landscape changes.

    Science.gov (United States)

    Bonthoux, Sébastien; Barnagaud, Jean-Yves; Goulard, Michel; Balent, Gérard

    2013-06-01

    Quantifying the impact of land-use changes on biodiversity is a major challenge in conservation ecology. Static spatial relationships between bird communities and agricultural landscapes have been extensively studied. Yet, their ability to mirror the effects of temporal land-use dynamics remains to be demonstrated. Here, we test whether such space-for-time substitution approaches are relevant for explaining temporal variations in farmland bird communities. We surveyed 256 bird communities in an agricultural landscape in southwest France at the same locations in 1982 and 2007, and quantified the same seven landscape descriptors for each period. We compared the effects of spatial and temporal landscape changes over this 25-year period on bird species distributions and three community-level metrics: species richness and two community indices reflecting birds' specialisation regarding local vegetation structure (local CSI) and landscape composition (landscape CSI). Landscape heterogeneity decreased between 1982 and 2007 and crop area increased sharply at the expense of grassland as a result of agricultural intensification. We found that the correlations between temporal changes in bird distributions or community metrics and landscape components were less consistent than their spatial relationships in each year. This result advocates caution when using a space-for-time substitution approach to assess the effects of landscape changes on biodiversity. Additionally, community metrics showed contrasted responses to landscape changes. Species richness and local CSI for each period were negatively related to the area of crops and positively related to landscape heterogeneity. Conversely, the landscape CSI was positively related to the area of crop and negatively to landscape heterogeneity. To understand the ecological processes linked to changes in farm landscapes, our study underlines the need to develop long-term studies with bird and habitat data collected during several

  9. Application of dynamic susceptibility contrast-enhanced perfusion in temporal lobe epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Wu; Wang, Xiaoyi; Xie, Fangfang; Liao, Weihua [Dept. of Radiology, Xiangya Hospital of Central South Univ., Changsha (China)], e-mail: doctoring@sina.com

    2013-02-15

    Background: Accurately locatithe epileptogenic focus in temporal lobe epilepsy (TLE) is important in clinical practice. Single-photon emission computed tomography (SPECT) and positron-emission tomography (PET) have been widely used in the lateralization of TLE, but both have limitations. Magnetic resonance perfusion imaging can accurately and reliably reflect differences in cerebral blood flow and volume. Purpose: To investigate the diagnostic value of dynamic susceptibility contrast-enhanced (DSC) perfusion magnetic resonance imaging (MRI) in the lateralization of the epileptogenic focus in TLE. Material and Methods: Conventional MRI and DSC-MRI scanning was performed in 20 interictal cases of TLE and 20 healthy volunteers. The relative cerebral blood volume (rCBV) and relative cerebral blood flow (rCBF) of the bilateral mesial temporal lobes of the TLE cases and healthy control groups were calculated. The differences in the perfusion asymmetry indices (AIs), derived from the rCBV and rCBF of the bilateral mesial temporal lobes, were pared between the two groups. Results: In the control group, there were no statistically significant differences between the left and right sides in terms of rCBV (left 1.55 {+-} 0.32, right 1.57 {+-} 0.28) or rCBF (left 99.00 {+-} 24.61, right 100.38 {+-} 23.46) of the bilateral mesial temporal lobes. However, in the case group the ipsilateral rCBV and rCBF values (1.75 {+-} 0.64 and 96.35 {+-} 22.63, respectively) were markedly lower than those of the contralateral side (2.01 {+-} 0.79 and 108.56 {+-} 26.92; P < 0.05). Both the AI of the rCBV (AIrCBV; 13.03 {+-} 10.33) and the AI of the rCBF (AIrCBF; 11.24 {+-} 8.70) of the case group were significantly higher than that of the control group (AIrCBV 5.55 {+-} 3.74, AIrCBF 5.12 {+-} 3.48; P < 0.05). The epileptogenic foci of nine patients were correctly lateralized using the 95th percentile of the AIrCBV and AIrCBF of the control group as the normal upper limits. Conclusion: In

  10. Reduced-Contrast Approximations for High-Contrast Multiscale Flow Problems

    KAUST Repository

    Chung, Eric T.

    2010-01-01

    In this paper, we study multiscale methods for high-contrast elliptic problems where the media properties change dramatically. The disparity in the media properties (also referred to as high contrast in the paper) introduces an additional scale that needs to be resolved in multiscale simulations. First, we present a construction that uses an integral equation to represent the highcontrast component of the solution. This representation involves solving an integral equation along the interface where the coefficients are discontinuous. The integral representation suggests some multiscale approaches that are discussed in the paper. One of these approaches entails the use of interface functions in addition to multiscale basis functions representing the heterogeneities without high contrast. In this paper, we propose an approximation for the solution of the integral equation using the interface problems in reduced-contrast media. Reduced-contrast media are obtained by lowering the variance of the coefficients. We also propose a similar approach for the solution of the elliptic equation without using an integral representation. This approach is simpler to use in the computations because it does not involve setting up integral equations. The main idea of this approach is to approximate the solution of the high-contrast problem by the solutions of the problems formulated in reduced-contrast media. In this approach, a rapidly converging sequence is proposed where only problems with lower contrast are solved. It was shown that this sequence possesses the convergence rate that is inversely proportional to the reduced contrast. This approximation allows choosing the reduced-contrast problem based on the coarse-mesh size as discussed in this paper. We present a simple application of this approach to homogenization of elliptic equations with high-contrast coefficients. The presented approaches are limited to the cases where there are sharp changes in the contrast (i.e., the high

  11. CONTRAST

    DEFF Research Database (Denmark)

    Kristensen, Thomas Krogsgaard

    2007-01-01

    Dette er en afrapportering fra den årlige CONTRAST workshop, der i 2007 blev afholdt i Yaoundé, Cameroon.......Dette er en afrapportering fra den årlige CONTRAST workshop, der i 2007 blev afholdt i Yaoundé, Cameroon....

  12. Fish and Phytoplankton Exhibit Contrasting Temporal Species Abundance Patterns in a Dynamic North Temperate Lake

    Science.gov (United States)

    Hansen, Gretchen J. A.; Carey, Cayelan C.

    2015-01-01

    Temporal patterns of species abundance, although less well-studied than spatial patterns, provide valuable insight to the processes governing community assembly. We compared temporal abundance distributions of two communities, phytoplankton and fish, in a north temperate lake. We used both 17 years of observed relative abundance data as well as resampled data from Monte Carlo simulations to account for the possible effects of non-detection of rare species. Similar to what has been found in other communities, phytoplankton and fish species that appeared more frequently were generally more abundant than rare species. However, neither community exhibited two distinct groups of “core” (common occurrence and high abundance) and “occasional” (rare occurrence and low abundance) species. Both observed and resampled data show that the phytoplankton community was dominated by occasional species appearing in only one year that exhibited large variation in their abundances, while the fish community was dominated by core species occurring in all 17 years at high abundances. We hypothesize that the life-history traits that enable phytoplankton to persist in highly dynamic environments may result in communities dominated by occasional species capable of reaching high abundances when conditions allow. Conversely, longer turnover times and broad environmental tolerances of fish may result in communities dominated by core species structured primarily by competitive interactions. PMID:25651399

  13. Temporal assessment of microbial communities in soils of two contrasting mangroves.

    Science.gov (United States)

    Rigonato, Janaina; Kent, Angela D; Gumiere, Thiago; Branco, Luiz Henrique Zanini; Andreote, Fernando Dini; Fiore, Marli Fátima

    Variations in microbial communities promoted by alterations in environmental conditions are reflected in similarities/differences both at taxonomic and functional levels. Here we used a natural gradient within mangroves from seashore to upland, to contrast the natural variability in bacteria, cyanobacteria and diazotroph assemblages in a pristine area compared to an oil polluted area along a timespan of three years, based on ARISA (bacteria and cyanobacteria) and nifH T-RFLP (diazotrophs) fingerprinting. The data presented herein indicated that changes in all the communities evaluated were mainly driven by the temporal effect in the contaminated area, while local effects were dominant on the pristine mangrove. A positive correlation of community structure between diazotrophs and cyanobacteria was observed, suggesting the functional importance of this phylum as nitrogen fixers in mangroves soils. Different ecological patterns explained the microbial behavior in the pristine and polluted mangroves. Stochastic models in the pristine mangrove indicate that there is not a specific environmental factor that determines the bacterial distribution, while cyanobacteria and diazotrophs better fitted in deterministic model in the same area. For the contaminated mangrove site, deterministic models better represented the variations in the communities, suggesting that the presence of oil might change the microbial ecological structures over time. Mangroves represent a unique environment threatened by global change, and this study contributed to the knowledge of the microbial distribution in such areas and its response on persistent contamination historic events. Copyright © 2017 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  14. Asymptotic expansions for high-contrast linear elasticity

    KAUST Repository

    Poveda, Leonardo A.

    2015-03-01

    We study linear elasticity problems with high contrast in the coefficients using asymptotic limits recently introduced. We derive an asymptotic expansion to solve heterogeneous elasticity problems in terms of the contrast in the coefficients. We study the convergence of the expansion in the H1 norm. © 2015 Elsevier B.V.

  15. Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Mo, E-mail: Sunmo.Kim@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada); Haider, Masoom A. [Department of Medical Imaging, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5, Canada and Department of Medical Imaging, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Yeung, Ivan W. T. [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada); Department of Medical Physics, Stronach Regional Cancer Centre, Southlake Regional Health Centre, Newmarket, Ontario L3Y 2P9 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)

    2016-01-15

    Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the

  16. High Contrast Vacuum Nuller Testbed (VNT) Contrast, Performance and Null Control

    Science.gov (United States)

    Lyon, Richard G.; Clampin, Mark; Petrone, Peter; Mallik, Udayan; Madison, Timothy; Bolcar, Matthew R.

    2012-01-01

    Herein we report on our Visible Nulling Coronagraph high-contrast result of 109 contrast averaged over a focal planeregion extending from 14 D with the Vacuum Nuller Testbed (VNT) in a vibration isolated vacuum chamber. TheVNC is a hybrid interferometriccoronagraphic approach for exoplanet science. It operates with high Lyot stopefficiency for filled, segmented and sparse or diluted-aperture telescopes, thereby spanning the range of potential futureNASA flight telescopes. NASAGoddard Space Flight Center (GSFC) has a well-established effort to develop the VNCand its technologies, and has developed an incremental sequence of VNC testbeds to advance this approach and itsenabling technologies. These testbeds have enabled advancement of high-contrast, visible light, nulling interferometry tounprecedented levels. The VNC is based on a modified Mach-Zehnder nulling interferometer, with a W configurationto accommodate a hex-packed MEMS based deformable mirror, a coherent fiber bundle and achromatic phase shifters.We give an overview of the VNT and discuss the high-contrast laboratory results, the optical configuration, criticaltechnologies and null sensing and control.

  17. Asymptotic expansions for high-contrast elliptic equations

    KAUST Repository

    Calo, Victor M.

    2014-03-01

    In this paper, we present a high-order expansion for elliptic equations in high-contrast media. The background conductivity is taken to be one and we assume the medium contains high (or low) conductivity inclusions. We derive an asymptotic expansion with respect to the contrast and provide a procedure to compute the terms in the expansion. The computation of the expansion does not depend on the contrast which is important for simulations. The latter allows avoiding increased mesh resolution around high conductivity features. This work is partly motivated by our earlier work in [Domain decomposition preconditioners for multiscale flows in high-contrast media, Multiscale Model Simul. 8 (2010) 1461-1483] where we design efficient numerical procedures for solving high-contrast problems. These multiscale approaches require local solutions and our proposed high-order expansion can be used to approximate these local solutions inexpensively. In the case of a large-number of inclusions, the proposed analysis can help to design localization techniques for computing the terms in the expansion. In the paper, we present a rigorous analysis of the proposed high-order expansion and estimate the remainder of it. We consider both high-and low-conductivity inclusions. © 2014 World Scientific Publishing Company.

  18. Dynamic Contrast-Enhanced MRI of Cervical Cancers: Temporal Percentile Screening of Contrast Enhancement Identifies Parameters for Prediction of Chemoradioresistance

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Erlend K.F. [Department of Medical Physics, Oslo University Hospital, Oslo (Norway); Hole, Knut Hakon; Lund, Kjersti V. [Department of Radiology, Oslo University Hospital, Oslo (Norway); Sundfor, Kolbein [Department of Gynaecological Oncology, Oslo University Hospital, Oslo (Norway); Kristensen, Gunnar B. [Department of Gynaecological Oncology, Oslo University Hospital, Oslo (Norway); Institute for Medical Informatics, Oslo University Hospital, Oslo (Norway); Lyng, Heidi [Department of Radiation Biology, Oslo University Hospital, Oslo (Norway); Malinen, Eirik, E-mail: eirik.malinen@fys.uio.no [Department of Medical Physics, Oslo University Hospital, Oslo (Norway); Department of Physics, University of Oslo, Oslo (Norway)

    2012-03-01

    Purpose: To systematically screen the tumor contrast enhancement of locally advanced cervical cancers to assess the prognostic value of two descriptive parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Methods and Materials: This study included a prospectively collected cohort of 81 patients who underwent DCE-MRI with gadopentetate dimeglumine before chemoradiotherapy. The following descriptive DCE-MRI parameters were extracted voxel by voxel and presented as histograms for each time point in the dynamic series: normalized relative signal increase (nRSI) and normalized area under the curve (nAUC). The first to 100th percentiles of the histograms were included in a log-rank survival test, resulting in p value and relative risk maps of all percentile-time intervals for each DCE-MRI parameter. The maps were used to evaluate the robustness of the individual percentile-time pairs and to construct prognostic parameters. Clinical endpoints were locoregional control and progression-free survival. The study was approved by the institutional ethics committee. Results: The p value maps of nRSI and nAUC showed a large continuous region of percentile-time pairs that were significantly associated with locoregional control (p < 0.05). These parameters had prognostic impact independent of tumor stage, volume, and lymph node status on multivariate analysis. Only a small percentile-time interval of nRSI was associated with progression-free survival. Conclusions: The percentile-time screening identified DCE-MRI parameters that predict long-term locoregional control after chemoradiotherapy of cervical cancer.

  19. Slice-accelerated gradient-echo echo planar imaging dynamic susceptibility contrast-enhanced MRI with blipped CAIPI: effect of increasing temporal resolution.

    Science.gov (United States)

    Takamura, Tomohiro; Hori, Masaaki; Kamagata, Koji; Kumamaru, Kanako K; Irie, Ryusuke; Hagiwara, Akifumi; Hamasaki, Nozomi; Aoki, Shigeki

    2018-01-01

    To assess the influence of high temporal resolution on the perfusion measurements and image quality of perfusion maps, by applying simultaneous-multi-slice acquisition (SMS) dynamic susceptibility contrast-enhanced (DSC) magnetic resonance imaging (MRI). DSC-MRI data using SMS gradient-echo echo planar imaging sequences in 10 subjects with no intracranial abnormalities were retrospectively analyzed. Three additional data sets with temporal resolution of 1.0, 1.5, and 2.0 s were created from the raw data sets of 0.5 s. Cerebral blood flow (CBF), cerebral blood volume, mean transit time (MTT), time to peak (TTP), and time to maximum tissue residue function (T max ) measurements were performed, as was visual perfusion map analysis. The perfusion parameter for temporal resolution of 0.5 s (reference) was compared with each synthesized perfusion parameter. CBF, MTT, and TTP values at temporal resolutions of 1.5 and 2.0 s differed significantly from the reference. The image quality of MTT, TTP, and T max maps deteriorated with decreasing temporal resolution. The temporal resolution of DSC-MRI influences perfusion parameters and SMS DSC-MRI provides better image quality for MTT, TTP, and T max maps.

  20. Phase contrast imaging with coherent high energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Snigireva, I. [ESRF, Grenoble (France)

    1997-02-01

    X-ray imaging concern high energy domain (>6 keV) like a contact radiography, projection microscopy and tomography is used for many years to discern the features of the internal structure non destructively in material science, medicine and biology. In so doing the main contrast formation is absorption that makes some limitations for imaging of the light density materials and what is more the resolution of these techniques is not better than 10-100 {mu}m. It was turned out that there is now way in which to overcome 1{mu}m or even sub-{mu}m resolution limit except phase contrast imaging. It is well known in optics that the phase contrast is realised when interference between reference wave front and transmitted through the sample take place. Examples of this imaging are: phase contrast microscopy suggested by Zernike and Gabor (in-line) holography. Both of this techniques: phase contrast x-ray microscopy and holography are successfully progressing now in soft x-ray region. For imaging in the hard X-rays to enhance the contrast and to be able to resolve phase variations across the beam the high degree of the time and more importantly spatial coherence is needed. Because of this it was reasonable that the perfect crystal optics was involved like Bonse-Hart interferometry, double-crystal and even triple-crystal set-up using Laue and Bragg geometry with asymmetrically cut crystals.

  1. Futures full of promise, futures of despair. Contrasting temporalities in the life narrative of young Czechs

    Directory of Open Access Journals (Sweden)

    Haldis Haukanes

    2017-06-01

    Full Text Available On the backdrop of increasing anxieties about the state of the world and its future found among by scholars and grassroots alike, this article explores young people’s narratives of the future, paying particular attention to dominant temporal structures through which the young people frame their expectations and imagine their lives to come. The article builds on research with young Czechs in three different regions of the country, carried out in the years 2007–2009 and 2014–2016. In addition it incorporates elements from my former work on post-socialist transformations in rural Czech Republic. Drawing on anthropological debates about time, agency and social change, and on recent scholarship on nostalgia, I argue for the necessity of a diversified understanding of temporality when analysing narrations of both lived lives and future visions; linear and reproductive temporalities appear to co-exist with conceptions of time as accelerated, incoherent and unpredictable. Further, I argue that time or temporality is not just something which people are subject to; it also involves agency. This implies that well-established temporal frameworks can be used to narrate expectations for the future, or that different temporal frameworks can be strategically combined to manage both the present and the future.

  2. Polarization-Independent Wideband High-Index-Contrast Grating Mirror

    DEFF Research Database (Denmark)

    Bekele, Dagmawi Alemayehu; Park, Gyeong Cheol; Malureanu, Radu

    2015-01-01

    Island-type two-dimensional high-index-contrast grating mirror based on a standard silicon-on-insulator wafer have been experimentally demonstrated. The measured spectra shows a bandwidth of ∼192 nm with a reflectivity over 99% as well as polarization independence. Numerical simulations show...... that the designed mirror has large tolerance to fabrication errors....

  3. The V-SHARK high contrast imager at LBT

    Science.gov (United States)

    Pedichini, F.; Ambrosino, F.; Centrone, M.; Farinato, J.; Li Causi, G.; Pinna, E.; Puglisi, A.; Stangalini, M.; Testa, V.

    2016-08-01

    In the framework of the SHARK project the visible channel is a novel instrument synergic to the NIR channel and exploiting the performances of the LBT XAO at visible wavelengths. The status of the project is presented together with the design study of this innovative instrument optimized for high contrast imaging by means of high frame rate. Its expected results will be presented comparing the simulations with the real data of the "Forerunner" experiment taken at 630nm.

  4. Gd-HOPO Based High Relaxivity MRI Contrast Agents

    Energy Technology Data Exchange (ETDEWEB)

    Datta, Ankona; Raymond, Kenneth

    2008-11-06

    Tris-bidentate HOPO-based ligands developed in our laboratory were designed to complement the coordination preferences of Gd{sup 3+}, especially its oxophilicity. The HOPO ligands provide a hexadentate coordination environment for Gd{sup 3+} in which all he donor atoms are oxygen. Because Gd{sup 3+} favors eight or nine coordination, this design provides two to three open sites for inner-sphere water molecules. These water molecules rapidly exchange with bulk solution, hence affecting the relaxation rates of bulk water olecules. The parameters affecting the efficiency of these contrast agents have been tuned to improve contrast while still maintaining a high thermodynamic stability for Gd{sup 3+} binding. The Gd- HOPO-based contrast agents surpass current commercially available agents ecause of a higher number of inner-sphere water molecules, rapid exchange of inner-sphere water molecules via an associative mechanism, and a long electronic relaxation time. The contrast enhancement provided by these agents is at least twice that of commercial contrast gents, which are based on polyaminocarboxylate ligands.

  5. Spatial and temporal variability of grass cover in two olive grove catchments on contrasting soil types

    Science.gov (United States)

    Aguilera, Laura; Taguas, Encarnación V.; Gimeno, Enrique; Gómez, José A.

    2013-04-01

    Mediterranean climate conditions -characterized by the concentration of the precipitation in the seasons of autumn and spring, the low temperatures in winter and extremely warm and dry summers- determine that ground cover by adventitious (or cover crop) vegetation shows significant seasonal and annual variability. In addition, its spatial variability associates also, partially, to water availability among the landscape. This is especially relevant in olive orchards, an agricultural system under high erosion risk in the region where the establishment of herbaceous cover has proved to improve soil protection reducing erosion risk, as well as the improvement of soil properties (Gómez et al., 2009). All these benefits are based on small scale studies where full ground cover by the cover crop is relatively easy to obtain. However, few information is available about the actual ground cover achieved at farm scale, although preliminary observations suggests that this might be extremely variable (Gómez and Giráldez, 2009). This study presents the preliminary results evaluating the spatial and temporal evolution of ground cover by adventitious vegetation (the preferred option by farmers to achieve a cover crop) in two commercial olive farms during 2 hydrological years (2011-2012). The study was conducted in two farms located in the province of Cordoba, Southern Spain. Both were olive orchards grown under deficit irrigation systems and present a gauge station where rainfall, runoff and sediment loads have been measured from the year 2005. The soil management in "La Conchuela" farm was based in the use of herbicide in the line of olive trees to keep the bare soil all year round, and the application of selective herbicide in the lane between the olive trees to promote the grown of graminaceae grasses . In addition, the grass is mechanically killed in June. In the another farm, "Arroyo Blanco", the grass spontaneous cover is allowed until mid-spring in which is also

  6. Moderate contrast in the evaluation of paintings is liked more but remembered less than high contrast

    National Research Council Canada - National Science Library

    Dijkstra, Katinka; van Dongen, N.N.N

    2017-01-01

    .... The results indicated that for art appreciation, a moderate increase in contrast resulted in the highest appreciation for paintings whereas recognition memory was better for paintings with a higher increase in contrast...

  7. Topological Data Analysis of High-Resolution Temporal Rainfall

    Science.gov (United States)

    Carsteanu, Alin Andrei; Fernández Méndez, Félix; Vásquez Aguilar, Raciel

    2017-04-01

    This study applies topological data analysis (TDA) to the state space representations of high-resolution temporal rainfall intensity data from Iowa City (IIHR, U of Iowa). Using a sufficient embedding dimension, topological properties of the underlying manifold are depicted.

  8. Computationally Designed Oligomers for High Contrast Black Electrochromic Polymers

    Science.gov (United States)

    2017-05-05

    AFRL-AFOSR-VA-TR-2017-0097 Computationally Designed Oligomers for High Contrast Black Electrochromic Polymers Aimee Tomlinson University Of North...Black Electrochromic FA9550-15-1-0181 Polymers 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6.AUTHO~ 5d. PROJECT NUMBER AimeeL. T . Se. TASK...neraly black neutral state. Additionally, upon oxidation these polymers would have litte to no tailing form the near IR thereby guaranteeing nearly a I

  9. High-contrast x-ray microtomography in dental research

    Science.gov (United States)

    Davis, Graham; Mills, David

    2017-09-01

    X-ray microtomography (XMT) is a well-established technique in dental research. The technique has been used extensively to explore the complex morphology of the root canal system, and to qualitatively and quantitatively evaluate root canal instrumentation and filling efficacy in extracted teeth; enabling different techniques to be compared. Densitometric information can be used to identify and map demineralized tissue resulting from tooth decay (caries) and, in extracted teeth, the method can be used to evaluate different methods of excavation. More recently, high contrast XMT is being used to investigate the relationship between external insults to teeth and the pulpal reaction. When such insults occur, fluid may flow through dentinal tubules as a result of cracking or porosity in enamel. Over time, there is an increase in mineralization along the paths of the tubules from the pulp to the damaged region in enamel and this can be visualized using high contrast XMT. The scanner used for this employs time-delay integration to minimize the effects of detector inhomogeneity in order to greatly increase the upper limit on signal-to-noise ratio that can be achieved with long exposure times. When enamel cracks are present in extracted teeth, the presence of these pathways indicates that the cracking occurred prior to extraction. At high contrast, growth lines are occasionally seen in deciduous teeth which may have resulted from periods of maternal illness. Various other anomalies in mineralization resulting from trauma or genetic abnormalities can also be investigated using this technique.

  10. High contrast observations of bright stars with a starshade

    Science.gov (United States)

    Harness, Anthony; Cash, Webster; Warwick, Steve

    2017-12-01

    Starshades are a leading technology to enable the direct detection and spectroscopic characterization of Earth-like exoplanets. In an effort to advance starshade technology through system level demonstrations, the McMath-Pierce Solar Telescope was adapted to enable the suppression of astronomical sources with a starshade. The long baselines achievable with the heliostat provide measurements of starshade performance at a flight-like Fresnel number and resolution, aspects critical to the validation of optical models. The heliostat has provided the opportunity to perform the first astronomical observations with a starshade and has made science accessible in a unique parameter space, high contrast at moderate inner working angles. On-sky images are valuable for developing the experience and tools needed to extract science results from future starshade observations. We report on high contrast observations of nearby stars provided by a starshade. We achieve 5.6 × 10- 7 contrast at 30 arcseconds inner working angle on the star Vega and provide new photometric constraints on background stars near Vega.

  11. Moderate Contrast in the Evaluation of Paintings Is Liked More but Remembered Less than High Contrast

    Directory of Open Access Journals (Sweden)

    Katinka Dijkstra

    2017-09-01

    Full Text Available Many visual aspects of paintings, as well as exposure to art and cultural norms, contribute to the aesthetic evaluation of paintings. The current study looked at heightened visual contrast as an important factor in the appreciation of paintings. Participants evaluated abstract digitized paintings that were manipulated in contrast for an appreciation task and were later presented with these paintings in a memory task. The results indicated that for art appreciation, a moderate increase in contrast resulted in the highest appreciation for paintings whereas recognition memory was better for paintings with a higher increase in contrast. These results replicate earlier findings with regard to the role of contrast in aesthetic perception and extend these findings by demonstrating a surprising different effect of contrast manipulation for recognition memory. Confidence with which memory decisions were made was in line with art appreciation decisions not memory performance.

  12. Moderate Contrast in the Evaluation of Paintings Is Liked More but Remembered Less than High Contrast.

    Science.gov (United States)

    Dijkstra, Katinka; van Dongen, Noah N N

    2017-01-01

    Many visual aspects of paintings, as well as exposure to art and cultural norms, contribute to the aesthetic evaluation of paintings. The current study looked at heightened visual contrast as an important factor in the appreciation of paintings. Participants evaluated abstract digitized paintings that were manipulated in contrast for an appreciation task and were later presented with these paintings in a memory task. The results indicated that for art appreciation, a moderate increase in contrast resulted in the highest appreciation for paintings whereas recognition memory was better for paintings with a higher increase in contrast. These results replicate earlier findings with regard to the role of contrast in aesthetic perception and extend these findings by demonstrating a surprising different effect of contrast manipulation for recognition memory. Confidence with which memory decisions were made was in line with art appreciation decisions not memory performance.

  13. Electron acceleration via high contrast laser interacting with submicron clusters

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Lu; Chen Liming; Wang Weiming; Yan Wenchao; Yuan Dawei; Mao Jingyi; Wang Zhaohua; Liu Cheng; Shen Zhongwei; Li Yutong; Dong Quanli; Lu Xin; Ma Jinglong; Wei Zhiyi [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, CAS, Beijing 100080 (China); Faenov, Anatoly; Pikuz, Tatiana [Joint Institute for High Temperature of the Russian Academy of Sciences, Izhorskaya 13/19, Moscow 127412 (Russian Federation); Quantum Beams Science Directorate, JAEA, Kizugawa, Kyoto (Japan); Li Dazhang [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, CAS, Beijing 100080 (China); Institute of High Energy Physics, CAS, Beijing 100049 (China); Sheng Zhengming [Department of Physics, Shanghai Jiao Tong University, Shanghai 200240 (China); Zhang Jie [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, CAS, Beijing 100080 (China); Department of Physics, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2012-01-02

    We experimentally investigated electron acceleration from submicron size argon clusters-gas target irradiated by a 100 fs, 10 TW laser pulses having a high-contrast. Electron beams are observed in the longitudinal and transverse directions to the laser propagation. The measured energy of the longitudinal electron reaches 600 MeV and the charge of the electron beam in the transverse direction is more than 3 nC. A two-dimensional particle-in-cell simulation of the interaction has been performed and it shows an enhancement of electron charge by using the cluster-gas target.

  14. High Contrast Imaging of Exoplanets and Exoplanetary Systems with JWST

    Science.gov (United States)

    Hinkley, Sasha; Skemer, Andrew; Biller, Beth; Baraffe, I.; Bonnefoy, M.; Bowler, B.; Carter, A.; Chen, C.; Choquet, E.; Currie, T.; Danielski, C.; Fortney, J.; Grady, C.; Greenbaum, A.; Hines, D.; Janson, M.; Kalas, P.; Kennedy, G.; Kraus, A.; Lagrange, A.; Liu, M.; Marley, M.; Marois, C.; Matthews, B.; Mawet, D.; Metchev, S.; Meyer, M.; Millar-Blanchaer, M.; Perrin, M.; Pueyo, L.; Quanz, S.; Rameau, J.; Rodigas, T.; Sallum, S.; Sargent, B.; Schlieder, J.; Schneider, G.; Stapelfeldt, K.; Tremblin, P.; Vigan, A.; Ygouf, M.

    2017-11-01

    JWST will transform our ability to characterize directly imaged planets and circumstellar debris disks, including the first spectroscopic characterization of directly imaged exoplanets at wavelengths beyond 5 microns, providing a powerful diagnostic of cloud particle properties, atmospheric structure, and composition. To lay the groundwork for these science goals, we propose a 39-hour ERS program to rapidly establish optimal strategies for JWST high contrast imaging. We will acquire: a) coronagraphic imaging of a newly discovered exoplanet companion, and a well-studied circumstellar debris disk with NIRCam & MIRI; b) spectroscopy of a wide separation planetary mass companion with NIRSPEC & MIRI; and c) deep aperture masking interferometry with NIRISS. Our primary goals are to: 1) generate representative datasets in modes to be commonly used by the exoplanet and disk imaging communities; 2) deliver science enabling products to empower a broad user base to develop successful future investigations; and 3) carry out breakthrough science by characterizing exoplanets for the first time over their full spectral range from 2-28 microns, and debris disk spectrophotometry out to 15 microns sampling the 3 micron water ice feature. Our team represents the majority of the community dedicated to exoplanet and disk imaging and has decades of experience with high contrast imaging algorithms and pipelines. We have developed a collaboration management plan and several organized working groups to ensure we can rapidly and effectively deliver high quality Science Enabling Products to the community.

  15. Temporal Processing Capacity in High-Level Visual Cortex Is Domain Specific.

    Science.gov (United States)

    Stigliani, Anthony; Weiner, Kevin S; Grill-Spector, Kalanit

    2015-09-09

    Prevailing hierarchical models propose that temporal processing capacity--the amount of information that a brain region processes in a unit time--decreases at higher stages in the ventral stream regardless of domain. However, it is unknown if temporal processing capacities are domain general or domain specific in human high-level visual cortex. Using a novel fMRI paradigm, we measured temporal capacities of functional regions in high-level visual cortex. Contrary to hierarchical models, our data reveal domain-specific processing capacities as follows: (1) regions processing information from different domains have differential temporal capacities within each stage of the visual hierarchy and (2) domain-specific regions display the same temporal capacity regardless of their position in the processing hierarchy. In general, character-selective regions have the lowest capacity, face- and place-selective regions have an intermediate capacity, and body-selective regions have the highest capacity. Notably, domain-specific temporal processing capacities are not apparent in V1 and have perceptual implications. Behavioral testing revealed that the encoding capacity of body images is higher than that of characters, faces, and places, and there is a correspondence between peak encoding rates and cortical capacities for characters and bodies. The present evidence supports a model in which the natural statistics of temporal information in the visual world may affect domain-specific temporal processing and encoding capacities. These findings suggest that the functional organization of high-level visual cortex may be constrained by temporal characteristics of stimuli in the natural world, and this temporal capacity is a characteristic of domain-specific networks in high-level visual cortex. Significance statement: Visual stimuli bombard us at different rates every day. For example, words and scenes are typically stationary and vary at slow rates. In contrast, bodies are dynamic

  16. Concentric circular focusing reflector realized using high index contrast gratings

    Science.gov (United States)

    Fang, Wenjing; Huang, Yongqing; Fei, Jiarui; Duan, Xiaofeng; Liu, Kai; Ren, Xiaomin

    2017-11-01

    A non-periodic concentric circular high index contrast grating (CC-HCG) focusing reflector on 500 nm silicon-on-insulator (SOI) platform is fabricated and experimentally demonstrated. The proposed mirror is realized with phase modulation of wave front in a high reflectivity region. The circular structure based HCG focusing reflector has a spot of high concentration at the 10.87 mm with normal incidence for radially polarization, along with the center wavelength set at 1550 nm. The FWHM spot size of the focusing beam decreases to 260 μm, and the intensity increases to 1.26 compared with the incident beam. The focusing efficiency of about 80% is observed at 1550 nm in the experimental measurement.

  17. 1060-nm Tunable Monolithic High Index Contrast Subwavelength Grating VCSEL

    DEFF Research Database (Denmark)

    Ansbæk, Thor; Chung, Il-Sug; Semenova, Elizaveta

    2013-01-01

    We present the first tunable vertical-cavity surface-emitting laser (VCSEL) where the top distributed Bragg reflector has been completely substituted by an air-cladded high-index-contrast subwavelength grating (HCG) mirror. In this way, an extended cavity design can be realized by reducing...... the reflection at the semiconductor #x2013;air interface using an anti-reflective coating (ARC). We demonstrate how the ARC can be integrated in a monolithic structure by oxidizing AlGaAs with high Al-content. The HCG VCSEL has the potential to achieve polarization stable single-mode output with high tuning...... efficiency. The HCG VCSEL shows a total tuning range of 16 nm around an emission wavelength of 1060 nm with 1-mW output power....

  18. Modeling the subjective quality of highly contrasted videos displayed on LCD with local backlight dimming.

    Science.gov (United States)

    Mantel, Claire; Bech, Søren; Korhonen, Jari; Forchhammer, Søren; Pedersen, Jesper Melgaard

    2015-02-01

    Local backlight dimming is a technology aiming at both saving energy and improving visual quality on television sets. As the rendition of the image is specified locally, the numerical signal corresponding to the displayed image needs to be computed through a model of the display. This simulated signal can then be used as input to objective quality metrics. The focus of this paper is on determining which characteristics of locally backlit displays influence quality assessment. A subjective experiment assessing the quality of highly contrasted videos displayed with various local backlight-dimming algorithms is set up. Subjective results are then compared with both objective measures and objective quality metrics using different display models. The first analysis indicates that the most significant objective features are temporal variations, power consumption (probably representing leakage), and a contrast measure. The second analysis shows that modeling of leakage is necessary for objective quality assessment of sequences displayed with local backlight dimming.

  19. Moderate Contrast in the Evaluation of Paintings Is Liked More but Remembered Less than High Contrast

    OpenAIRE

    Katinka Dijkstra; Noah N. N. van Dongen

    2017-01-01

    Many visual aspects of paintings, as well as exposure to art and cultural norms, contribute to the aesthetic evaluation of paintings. The current study looked at heightened visual contrast as an important factor in the appreciation of paintings. Participants evaluated abstract digitized paintings that were manipulated in contrast for an appreciation task and were later presented with these paintings in a memory task. The results indicated that for art appreciation, a moderate increase in cont...

  20. Multi-wavelength VCSEL arrays using high-contrast gratings

    Science.gov (United States)

    Haglund, Erik; Gustavsson, Johan S.; Sorin, Wayne V.; Bengtsson, Jörgen; Fattal, David; Haglund, Àsa; Tan, Michael; Larsson, Anders

    2017-02-01

    The use of a high-contrast grating (HCG) as the top mirror in a vertical-cavity surface-emitting laser (VCSEL) allows for setting the resonance wavelength by the grating parameters in a post-epitaxial growth fabrication process. Using this technique, we demonstrate electrically driven multi-wavelength VCSEL arrays at 980 nm wavelength. The VCSELs are GaAs-based and the suspended GaAs HCGs were fabricated using electron-beam lithography, dry etching and selective removal of an InGaP sacrificial layer. The air-coupled cavity design enabled 4-channel arrays with 5 nm wavelength spacing and sub-mA threshold currents thanks to the high HCG reflectance.

  1. Double high refractive-index contrast grating VCSEL

    Science.gov (United States)

    Gebski, Marcin; Dems, Maciej; Wasiak, Michał; Sarzała, Robert P.; Lott, J. A.; Czyszanowski, Tomasz

    2015-03-01

    Distributed Bragg reflectors (DBRs) are typically used as the highly reflecting mirrors of vertical-cavity surface-emitting lasers (VCSELs). In order to provide optical field confinement, oxide apertures are often incorporated in the process of the selective wet oxidation of high aluminum-content DBR layers. This technology has some potential drawbacks such as difficulty in controlling the uniformity of the oxide aperture diameters across a large-diameter (≥ 6 inch) production wafers, high DBR series resistance especially for small diameters below about 5 μm despite elaborate grading and doping schemes, free carrier absorption at longer emission wavelengths in the p-doped DBRs, reduced reliability for oxide apertures placed close to the quantum wells, and low thermal conductivity for transporting heat away from the active region. A prospective alternative mirror is a high refractive index contrast grating (HCG) monolithically integrated with the VCSEL cavity. Two HCG mirrors potentially offer a very compact and simplified VCSEL design although the problems of resistance, heat dissipation, and reliability are not completely solved. We present an analysis of a double HCG 980 nm GaAs-based ultra-thin VCSEL. We analyze the optical confinement of such a structure with a total optical thickness is ~1.0λ including the optical cavity and the two opposing and parallel HCG mirrors.

  2. Moderate contrast in the evaluation of paintings is liked more but remembered less than high contrast

    NARCIS (Netherlands)

    K. Dijkstra (Katinka); van Dongen, N.N.N. (Noah N.N.)

    2017-01-01

    textabstractMany visual aspects of paintings, as well as exposure to art and cultural norms, contribute to the aesthetic evaluation of paintings. The current study looked at heightened visual contrast as an important factor in the appreciation of paintings. Participants evaluated abstract digitized

  3. Optimal parameters of monolithic high-index contrast grating VCSELs

    Science.gov (United States)

    Marciniak, Magdalena; Gebski, Marcin; Dems, Maciej; Czyszanowski, Tomasz

    2016-04-01

    Monolithic High refractive index Contrast Grating (MHCG) allows several-fold size reduction of epitaxial structure of VCSEL and facilitates VCSEL fabrication in all photonic material systems. MHCGs can be fabricated of material which refractive index is higher than 1.75 without the need of the combination of low and high refractive index materials. MHCGs have a great application potential in optoelectronic devices, especially in phosphide- and nitride-based VCSELs, which suffer from the lack of efficient monolithically integrated DBR mirrors. MHCGs can simplify the construction of VCSELs, reducing their epitaxial design to monolithic wafer with carrier confinement and active region inside and etched stripes on both surfaces in post processing. In this paper we present results of numerical analysis of MHCGs as a high reflective mirrors for broad range of refractive indices that corresponds to plethora of materials typically used in optoelectronics. Our calculations base on a three-dimensional, fully vectorial optical model. We investigate the reflectance of the MHCG mirrors of different design as the function of the refractive index and we show the optimal geometrical parameters of MHCG enabling nearly 100% reflectance and broad reflection stop-band. We show that MHCG can be designed based on most of semiconductors materials and for any incident light wavelength from optical spectrum.

  4. Monolithic subwavelength high refractive-index-contrast grating VCSELs

    Science.gov (United States)

    Gebski, Marcin; Dems, Maciej; Lott, James A.; Czyszanowski, Tomasz

    2016-03-01

    In this paper we present optical design and simulation results of vertical-cavity surface-emitting lasers (VCSELs) that incorporate monolithic subwavelength high refractive-index-contrast grating (MHCG) mirrors - a new variety of HCG mirror that is composed of high index material surrounded only on one side by low index material. We show the impact of an MHCG mirror on the performance of 980 nm VCSELs designed for high bit rate and energy-efficient optical data communications. In our design, all or part of the all-semiconductor top coupling distributed Bragg reflector mirror is replaced by an undoped gallium-arsenide MHCG. We show how the optical field intensity distribution of the VCSEL's fundamental mode is controlled by the combination of the number of residual distributed Bragg reflector (DBR) mirror periods and the physical design of the topmost gallium-arsenide MHCG. Additionally, we numerically investigate the confinement factors of our VCSELs and show that this parameter for the MHCG DBR VCSELs may only be properly determined in two or three dimensions due to the periodic nature of the grating mirror.

  5. Generating high-temporal and spatial resolution tir image data

    NARCIS (Netherlands)

    Herrero Huerta, M.; Lagüela, S.; Alfieri, S.M.; Menenti, M.; Lichti, D.; Weng, Q

    2017-01-01

    Remote sensing imagery to monitor global biophysical dynamics requires the availability of thermal infrared data at high temporal and spatial resolution because of the rapid development of crops during the growing season and the fragmentation of most agricultural landscapes. Conversely, no single

  6. Temporal dynamics of high repetition rate pulsed single longitudinal ...

    Indian Academy of Sciences (India)

    Theoretical and experimental studies of temporal dynamics of grazing incidence grating (GIG) cavity, single-mode dye laser pumped by high repetition rate copper vapour laser (CVL) are presented. Spectral chirp of the dye laser as they evolve in the cavity due to transient phase dynamics of the amplifier gain medium is ...

  7. Compressed sensing for high frame rate, high resolution and high contrast ultrasound imaging.

    Science.gov (United States)

    Jing Liu; Qiong He; Jianwen Luo

    2015-08-01

    Compressed sensing (CS) or compressive sampling allows much lower sampling frequency than the Nyquist sampling frequency. In this paper, we propose a novel technique, named compressed sensing based synthetic transmit aperture (CS-STA), to speed up the acquisition of ultrasound imaging. Ultrasound transducer transmits plane wave with random apodizations for several times and receives the corresponding echoes. The full dataset of STA is then recovered from the recorded echoes using a CS reconstruction algorithm. Finally, a standard STA beamforming is performed on the dataset to form a B-mode image. When the number of CS-STA firings is smaller than the number of STA firings, higher frame rate is achieved. In addition, CS-STA maintains the high resolution of STA because of the CS recovered full dataset of STA, and improves the contrast due to plane wave firings. Computer simulations and phantom experiments are carried out to investigate the feasibility and performance of the proposed CS-STA method. The CS-STA method is proven to be capable of obtaining simultaneously high frame rate, high solution and high contrast ultrasound imaging.

  8. High temporal resolution functional MRI using parallel echo volumar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rabrait, C.; Ciuciu, P.; Ribes, A.; Poupon, C.; Dehaine-Lambertz, G.; LeBihan, D.; Lethimonnier, F. [CEA Saclay, DSV, I2BM, Neurospin, F-91191 Gif Sur Yvette (France); Le Roux, P. [GEHC, Buc (France); Dehaine-Lambertz, G. [Unite INSERM 562, Gif Sur Yvette (France)

    2008-07-01

    Purpose: To combine parallel imaging with 3D single-shot acquisition (echo volumar imaging, EVI) in order to acquire high temporal resolution volumar functional MRI (fMRI) data. Materials and Methods: An improved EVI sequence was associated with parallel acquisition and field of view reduction in order to acquire a large brain volume in 200 msec. Temporal stability and functional sensitivity were increased through optimization of all imaging parameters and Tikhonov regularization of parallel reconstruction. Two human volunteers were scanned with parallel EVI in a 1.5 T whole-body MR system, while submitted to a slow event-related auditory paradigm. Results: Thanks to parallel acquisition, the EVI volumes display a low level of geometric distortions and signal losses. After removal of low-frequency drifts and physiological artifacts,activations were detected in the temporal lobes of both volunteers and voxel-wise hemodynamic response functions (HRF) could be computed. On these HRF different habituation behaviors in response to sentence repetition could be identified. Conclusion: This work demonstrates the feasibility of high temporal resolution 3D fMRI with parallel EVI. Combined with advanced estimation tools,this acquisition method should prove useful to measure neural activity timing differences or study the nonlinearities and non-stationarities of the BOLD response. (authors)

  9. Active optics: off axis aspherics generation for high contrast imaging

    Science.gov (United States)

    Hugot, E.; Laslandes, M.; Ferrari, M.; Vives, S.; Moindrot, S.; El Hadi, K.; Dohlen, K.

    2017-11-01

    Active Optics methods, based on elasticity theory, allow the aspherisation of optical surfaces by stress polishing but also active aspherisation in situ. Researches in this field will impact the final performance and the final cost of any telescope or instrument. The stress polishing method is well suited for the superpolishing of aspheric components for astronomy. Its principle relies on spherical polishing with a full-sized tool of a warped substrate, which becomes aspherical once unwarped. The main advantage of this technique is the very high optical quality obtained either on form or on high spatial frequency errors. Furthermore, the roughness can be decreased down to a few angstroms, thanks the classical polishing with a large pitch tool, providing a substantial gain on the final scientific performance, for instance on the contrast on coronagraphic images, but also on the polishing time and cost. Stress polishing is based on elasticity theory, and requires an optimised deformation system able to provide the right aspherical form on the optical surface during polishing. The optical quality of the deformation is validated using extensive Finite Element Analysis, allowing an estimation of residuals and an optimisation of the warping harness. We describe here the work realised on stress polishing of toric mirrors for VLT-SPHERE and then our actual work on off axis aspherics (OAA) for the ASPIICS-Proba3 mission for solar coronagraphy. The ASPIICS optical design made by Vives et al is a three mirrors anastigmat including a concave off axis hyperboloid and a convex off axis parabola (OAP). We are developing a prototype in order to demonstrate the feasibility of this type of surface, using a multi-mode warping harness (Lemaitre et al). Furthermore, we present our work on variable OAP, meaning the possibility to adjust the shape of a simple OAP in situ with a minimal number of actuators, typically one actuator per optical mode (Focus, Coma and Astigmatism

  10. High monetary reward rates and caloric rewards decrease temporal persistence.

    Science.gov (United States)

    Fung, Bowen J; Bode, Stefan; Murawski, Carsten

    2017-02-22

    Temporal persistence refers to an individual's capacity to wait for future rewards, while forgoing possible alternatives. This requires a trade-off between the potential value of delayed rewards and opportunity costs, and is relevant to many real-world decisions, such as dieting. Theoretical models have previously suggested that high monetary reward rates, or positive energy balance, may result in decreased temporal persistence. In our study, 50 fasted participants engaged in a temporal persistence task, incentivised with monetary rewards. In alternating blocks of this task, rewards were delivered at delays drawn randomly from distributions with either a lower or higher maximum reward rate. During some blocks participants received either a caloric drink or water. We used survival analysis to estimate participants' probability of quitting conditional on the delay distribution and the consumed liquid. Participants had a higher probability of quitting in blocks with the higher reward rate. Furthermore, participants who consumed the caloric drink had a higher probability of quitting than those who consumed water. Our results support the predictions from the theoretical models, and importantly, suggest that both higher monetary reward rates and physiologically relevant rewards can decrease temporal persistence, which is a crucial determinant for survival in many species. © 2017 The Authors.

  11. Monolithic high-index contrast grating: a material independent high-reflectance VCSEL mirror.

    Science.gov (United States)

    Gębski, M; Dems, M; Szerling, A; Motyka, M; Marona, L; Kruszka, R; Urbańczyk, D; Walczakowski, M; Pałka, N; Wójcik-Jedlińska, A; Wang, Q J; Zhang, D H; Bugajski, M; Wasiak, M; Czyszanowski, T

    2015-05-04

    In this paper we present an extensive theoretical and numerical analysis of monolithic high-index contrast grating, facilitating simple manufacture of compact mirrors for very broad spectrum of vertical-cavity surface-emitting lasers (VCSELs) emitting from ultraviolet to mid-infrared. We provide the theoretical background explaining the phenomenon of high reflectance in monolithic subwavelength gratings. In addition, by using a three-dimensional, fully vectorial optical model, verified by comparison with the experiment, we investigate the optimal parameters of high-index contrast grating enabling more than 99.99% reflectance in the diversity of photonic materials and in the broad range of wavelengths.

  12. Psychophysics, reliability, and norm values for temporal contrast sensitivity implemented on the two alternative forced choice C-Quant device.

    Science.gov (United States)

    van den Berg, Thomas J T P; Franssen, Luuk; Kruijt, Bastiaan; Coppens, Joris E

    2011-08-01

    The current paper describes the design and population testing of a flicker sensitivity assessment technique corresponding to the psychophysical approach for straylight measurement. The purpose is twofold: to check the subjects' capability to perform the straylight test and as a test for retinal integrity for other purposes. The test was implemented in the Oculus C-Quant straylight meter, using homemade software (MATLAB). The geometry of the visual field lay-out was identical, as was the subjects' 2AFC task. A comparable reliability criterion ("unc") was developed. Outcome measure was logTCS (temporal contrast sensitivity). The population test was performed in science fair settings on about 400 subjects. Moreover, 2 subjects underwent extensive tests to check whether optical defects, mimicked with trial lenses and scatter filters, affected the TCS outcome. Repeated measures standard deviation was 0.11 log units for the reference population. Normal values for logTCS were around 2 (threshold 1%) with some dependence on age (range 6 to 85 years). The test outcome did not change upon a tenfold (optical) deterioration in visual acuity or straylight. The test has adequate precision for checking a subject's capability to perform straylight assessment. The unc reliability criterion ensures sufficient precision, also for assessment of retinal sensitivity loss.

  13. Electrical Capacitance Volume Tomography with High-Contrast Dielectrics

    Science.gov (United States)

    Nurge, Mark

    2010-01-01

    The Electrical Capacitance Volume Tomography (ECVT) system has been designed to complement the tools created to sense the presence of water in nonconductive spacecraft materials, by helping to not only find the approximate location of moisture but also its quantity and depth. The ECVT system has been created for use with a new image reconstruction algorithm capable of imaging high-contrast dielectric distributions. Rather than relying solely on mutual capacitance readings as is done in traditional electrical capacitance tomography applications, this method reconstructs high-resolution images using only the self-capacitance measurements. The image reconstruction method assumes that the material under inspection consists of a binary dielectric distribution, with either a high relative dielectric value representing the water or a low dielectric value for the background material. By constraining the unknown dielectric material to one of two values, the inverse math problem that must be solved to generate the image is no longer ill-determined. The image resolution becomes limited only by the accuracy and resolution of the measurement circuitry. Images were reconstructed using this method with both synthetic and real data acquired using an aluminum structure inserted at different positions within the sensing region. The cuboid geometry of the system has two parallel planes of 16 conductors arranged in a 4 4 pattern. The electrode geometry consists of parallel planes of copper conductors, connected through custom-built switch electronics, to a commercially available capacitance to digital converter. The figure shows two 4 4 arrays of electrodes milled from square sections of copper-clad circuit-board material and mounted on two pieces of glass-filled plastic backing, which were cut to approximately square shapes, 10 cm on a side. Each electrode is placed on 2.0-cm centers. The parallel arrays were mounted with the electrode arrays approximately 3 cm apart. The open ends

  14. Spatial and temporal instabilities in high voltage power devices

    Energy Technology Data Exchange (ETDEWEB)

    Milady, Saeed

    2010-01-29

    Dynamic avalanche can occur during the turn-off process of high voltage bipolar devices, e.g. IGBTs and p{sup +}n{sup -}n{sup +} power diodes, that may result in spatial instabilities of the homogeneous current density distribution across the device and the formation of current filaments. Filaments may cause the destruction of the device, mainly because of the high local temperatures. The first part of this work is dedicated to the current filament behavior. The positive feedback mechanisms caused by the transient current flow through the gate capacitance of an IGBT operating under short circuit conditions may result in oscillations and temporal instabilities of the IGBT current. The oscillations may cause electromagnetic interference (EMI). Furthermore, the positive feedback mechanism may accelerate the over-heating of the device and result in a thermal run-away. This is the subject of the second part of this work. In the first part of this work using the device simulation results of power diodes the underlying physical mechanisms of the filament dynamic is investigated. Simulation results of diode structures with evenly distributed doping inhomogeneities show that, the filament motion gets smoother as the distance between the inhomogeneities decreases. Hopping to faraway inhomogeneities turns into the hopping to neighboring ones and finally a smooth motion. In homogeneous structures the slow inhibitory effect of the electron-hole plasma extraction and the fast activation, due to hole current flowing along the filament, result in a smooth filament motion. An analytical model for the filament velocity under isothermal conditions is presented that can reproduce the simulation data satisfactorily. The influence of the boundary conditions on the filament behavior is discussed. The positive beveled edge termination prohibits a long stay of the filament at the edge reducing the risk of filament pinning. Self-heating effects may turn the initially electrically triggered

  15. Time-dependent convective flows with high viscosity contrasts under micro gravity conditions.

    Science.gov (United States)

    Zaussinger, Florian; Egbers, Christoph; Krebs, Andreas; Schwarzbach, Felix; Kunze, Christian

    2015-04-01

    Thermal driven convection in spherical geometry is of main interest in geo- and astrophysical research. To capture certain aspects of temperature dependent viscosity we investigate the micro-gravity experiment GeoFlow-IIb, located on the ISS. This unique experimental setup consists of a bottom heated and top cooled spherical gap, filled with the silicon oil 1-Nonanol. However, rotation and varying temperature gradients can be applied, to spread the experimental parameter space. The main focus of the current mission is the investigation of time dependent convective flow structures. Since the ISS requirements makes it impossible to use tracer particles, the flow structures are captured by interferometry, whose outcome is analysed by an ground based adapted image processing technique. To guarantee valid results the experimental time of each parameter is in the order of the thermal time scale, which is about 40 min. We are presenting latest results of plume-like and sheet-like time-dependent convective patterns in the spherical shell, their evolution and temporal behaviour under high viscosity contrasts. Due to an unexpected nonlinear coupling between the temperature dependent viscosity of the working fluid and the applied dielectrophoretic force field, we are able to maintain a viscosity contrast of 50 and more. This gives the chance to compare cautiously our experimental results with theoretical assumptions of the mantle convection theory. Besides, numerical simulations in the same parameter regime are performed, which give the opportunity to deduce the internal structure of the experimental flow flied. The main focus of the presented results are the long time temporal evolution of convective plumes in the spherical gap, image capturing- and processing techniques and the deduction of the internal flow field based on planar interferometry pictures.

  16. Ultrafast pump-probe microscopy with high temporal dynamic range.

    Science.gov (United States)

    Domke, Matthias; Rapp, Stephan; Schmidt, Michael; Huber, Heinz P

    2012-04-23

    Ultrafast pump-probe microscopy is a common method for time and space resolved imaging of short and ultra-short pulse laser ablation. The temporal delay between the ablating pump pulse and the illuminating probe pulse is tuned either by an optical delay, resulting in several hundred femtoseconds temporal resolution for delay times up to a few ns, or by an electronic delay, resulting in several nanoseconds resolution for longer delay times. In this work we combine both delay types for temporally high resolved observations of complete ablation processes ranging from femtoseconds to microseconds, while ablation is initiated by an ultrafast 660 fs laser pump pulse. For this purpose, we also demonstrate the calibration of the delay time zero point, the synchronization of both probe sources, as well as a method for image quality enhancing. In addition, we present for the first time to our knowledge pump-probe microscopy investigations of the complete substrate side selective ablation process of molybdenum films on glass. The initiation of mechanical film deformation is observed at about 400 ps, continues until approximately 15 ns, whereupon a Mo disk is sheared off free from thermal effects due to a directly induced laser lift-off ablation process. © 2012 Optical Society of America

  17. Development of microbubble contrast agents for high frequency ultrasound microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Se Jung; Kim, Eun A; Park, Sung Hoon; Lee, Hye Jin; Jun, Hong Young; Byun, Seung Jae; Yoon, Kwon Ha [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2007-05-15

    To develop optimal microbubble contrast agents (MBCAs) for performing ultrasound microscopy when examining small animals. We prepared three types of MBCAs. First, a mixture of three parts of 40% dextran and one part of 5% human serum albumin were sonicated with perfluorocarbon (PFC) (MB{sub 1}-D40A5P). Second, three parts of 40% dextran and one part of 1% human serum albumin were sonicated with PFC (MB{sub 2}-D40A1P). Third, all parts of 1% bovine serum albumin were sonicated with PFC (MB{sub 3}-A1P). We measured the microbubbles' sizes and concentrations with using image analysis software. The acoustic properties of the microbubbles were assessed both in vitro and in vivo. The majority of the MB{sub 1}-D40A5Ps had a diameter of 2-5 {mu} m, the mean diameter of the MB{sub 2}-D40A1Ps was 2.5 {mu} m, and the mean diameter of the MB{sub 3}-A1Ps was less than 2.0 {mu} m. Among the microbubbles, the MB{sub 1}-D40A5Ps and MB{sub 2}-D40A1Ps showed increased echogenicity in the abdominal vessels, but the duration of their contrast effect was less than 30 sec. On the contrary, the MB3-A1Ps exhibited strong enhancement in the vessels and their duration was greater than 120 sec. A microbubble contrast agent consisting of all parts of 1% serum albumin sonicated with PFC is an effective contrast agent for ultrasound microscopy.

  18. Ultra high spatial and temporal resolution breast imaging at 7T.

    Science.gov (United States)

    van de Bank, B L; Voogt, I J; Italiaander, M; Stehouwer, B L; Boer, V O; Luijten, P R; Klomp, D W J

    2013-04-01

    There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast-Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra-high spatial resolution can generally not be obtained during contrast uptake, whereas the relatively low spatial resolution of functional imaging (e.g. diffusion and perfusion) limits the detection of small lesions. To be able to increase spatial as well as temporal resolution simultaneously, the sensitivity of MR detection needs to increase as well as the ability to effectively accelerate the acquisition. The required gain in signal-to-noise ratio (SNR) can be obtained at 7T, whereas acceleration can be obtained with high-density receiver coil arrays. In this case, morphological imaging can be merged with DCE-MRI, and other functional techniques can be obtained at higher spatial resolution, and with less distortion [e.g. Diffusion Weighted Imaging (DWI)]. To test the feasibility of this concept, we developed a unilateral breast coil for 7T. It comprises a volume optimized dual-channel transmit coil combined with a 30-channel receive array coil. The high density of small coil elements enabled efficient acceleration in any direction to acquire ultra high spatial resolution MRI of close to 0.6 mm isotropic detail within a temporal resolution of 69 s, high spatial resolution MRI of 1.5 mm isotropic within an ultra high temporal resolution of 6.7 s and low distortion DWI at 7T, all validated in phantoms, healthy volunteers and a patient with a lesion in the right breast classified as Breast Imaging Reporting and Data System (BI-RADS) IV. Copyright © 2012 John Wiley & Sons, Ltd.

  19. Beam collimation with polycapillary x-ray optics for high contrast high resolution monochromatic imaging.

    Science.gov (United States)

    Sugiro, Francisca R; Li, Danhong; MacDonald, C A

    2004-12-01

    Monochromatic imaging can provide better contrast and resolution than conventional broadband radiography. In broadband systems, low energy photons do not contribute to the image, but are merely absorbed, while high energy photons produce scattering that degrades the image. By tuning to the optimal energy, one can eliminate undesirable lower and higher energies. Monochromatization is achieved by diffraction from a single crystal. A crystal oriented to diffract at a particular energy, in this case the characteristic line energy, diffracts only those photons within a narrow range of angles. The resultant beam from a divergent source is nearly parallel, but not very intense. To increase the intensity, collimation was performed with polycapillary x-ray optics, which can collect radiation from a divergent source and redirect it into a quasi parallel beam. Contrast and resolution measurements were performed with diffracting crystals with both high and low angular acceptance. Testing was first done at 8 keV with an intense copper rotating anode x-ray source, then 17.5 keV measurements were made with a low power molybdenum source. At 8 keV, subject contrast was a factor of five higher than for the polychromatic case. At 17.5 keV, monochromatic contrast was two times greater than the conventional polychromatic contrast. The subject contrasts measured at both energies were in good agreement with theory. An additional factor of two increase in contrast, for a total gain of four, is expected at 17.5 keV from the removal of scatter. Scatter might be simply removed using an air gap, which does not degrade resolution with a parallel beam.

  20. Magnetic Particle Imaging for High Temporal Resolution Assessment of Aneurysm Hemodynamics.

    Directory of Open Access Journals (Sweden)

    Jan Sedlacik

    Full Text Available The purpose of this work was to demonstrate the capability of magnetic particle imaging (MPI to assess the hemodynamics in a realistic 3D aneurysm model obtained by additive manufacturing. MPI was compared with magnetic resonance imaging (MRI and dynamic digital subtraction angiography (DSA.The aneurysm model was of saccular morphology (7 mm dome height, 5 mm cross-section, 3-4 mm neck, 3.5 mm parent artery diameter and connected to a peristaltic pump delivering a physiological flow (250 mL/min and pulsation rate (70/min. High-resolution (4 h long 4D phase contrast flow quantification (4D pc-fq MRI was used to directly assess the hemodynamics of the model. Dynamic MPI, MRI, and DSA were performed with contrast agent injections (3 mL volume in 3 s through a proximally placed catheter.4D pc-fq measurements showed distinct pulsatile flow velocities (20-80 cm/s as well as lower flow velocities and a vortex inside the aneurysm. All three dynamic methods (MPI, MRI, and DSA also showed a clear pulsation pattern as well as delayed contrast agent dynamics within the aneurysm, which is most likely caused by the vortex within the aneurysm. Due to the high temporal resolution of MPI and DSA, it was possible to track the contrast agent bolus through the model and to estimate the average flow velocity (about 60 cm/s, which is in accordance with the 4D pc-fq measurements.The ionizing radiation free, 4D high resolution MPI method is a very promising tool for imaging and characterization of hemodynamics in human. It carries the possibility of overcoming certain disadvantages of other modalities like considerably lower temporal resolution of dynamic MRI and limited 2D characteristics of DSA. Furthermore, additive manufacturing is the key for translating powerful pre-clinical techniques into the clinic.

  1. Photoacoustic lymphatic imaging with high spatial-temporal resolution

    Science.gov (United States)

    Martel, Catherine; Yao, Junjie; Huang, Chih-Hsien; Zou, Jun; Randolph, Gwendalyn J.; Wang, Lihong V.

    2014-11-01

    Despite its critical function in coordinating the egress of inflammatory and immune cells out of tissues and maintaining fluid balance, the causative role of lymphatic network dysfunction in pathological settings is still understudied. Engineered-animal models and better noninvasive high spatial-temporal resolution imaging techniques in both preclinical and clinical studies will help to improve our understanding of different lymphatic-related pathologic disorders. Our aim was to take advantage of our newly optimized noninvasive wide-field fast-scanning photoacoustic (PA) microcopy system to coordinately image the lymphatic vasculature and its flow dynamics, while maintaining high resolution and detection sensitivity. Here, by combining the optical-resolution PA microscopy with a fast-scanning water-immersible microelectromechanical system scanning mirror, we have imaged the lymph dynamics over a large field-of-view, with high spatial resolution and advanced detection sensitivity. Depending on the application, lymphatic vessels (LV) were spectrally or temporally differentiated from blood vessels. Validation experiments were performed on phantoms and in vivo to identify the LV. Lymphatic flow dynamics in nonpathological and pathological conditions were also visualized. These results indicate that our newly developed PA microscopy is a promising tool for lymphatic-related biological research.

  2. Post-processing of high-contrast observations of exoplanets

    Directory of Open Access Journals (Sweden)

    Gladysz S.

    2011-07-01

    Full Text Available Post-processing of images delivered by the eXtreme Adaptive Optics (XAO instrumentation is a crucial step which can increase achievable contrast even by two orders of magnitude. In this communication I present a new class of algorithms for detection of extrasolar planets from a sequence of adaptive-optics-corrected images. In general, the methods discriminate between real sources and stellar PSF features based on statistics of recorded intensity. The methods are particularly useful in dealing with static speckles which are the greatest obstacle in detecting exoplanets.

  3. P1-5: Effect of Luminance Contrast on the Color Selective Responses in the Inferior Temporal Cortex Neurons of the Macaque Monkey

    Directory of Open Access Journals (Sweden)

    Tomoyuki Namima

    2012-10-01

    Full Text Available Although the relationship between color signal and luminance signal is an important problem in visual perception, relatively little is known about how the luminance contrast affects the responses of color selective neurons in the visual cortex. In this study, we examined this problem in the inferior temporal (IT of the awake monkey performing a visual fixation task. Single neuron activities were recorded from the anterior and posterior color selective regions in IT cortex (AITC and PITC identified in previous studies where color selective neurons are accumulated. Color stimuli consisted of 28 stimuli that evenly distribute across the gamut of the CRT display defined on the CIE- xychromaticity diagram at two different luminance levels (5 cd/m 2or 20 cd/m 2 and 2 stimuli at white points. The background was maintained at 10 cd/m 2gray. We found that the effect of luminance contrast on the color selectivity was markedly different between AITC and PITC. When we examined the correlation between the responses to the bright stimuli and those to the dark stimuli with the same chromaticity coordinates, most AITC neurons exhibited high correlation whereas many PITC neurons showed no correlation or only weak correlation. In PITC, the effect was specifically large for neutral colors (white, gray, black and for colors with low saturation. These results indicate that the effect of luminance contrast on the color selective responses differs across different areas and suggest that the separation between color signal and luminance signal involves a higher stage of the cortical color processing.

  4. Synthesis of rainfall time series in a high temporal resolution

    Science.gov (United States)

    Callau Poduje, Ana Claudia; Haberlandt, Uwe

    2014-05-01

    In order to optimize the design and operation of urban drainage systems, long and continuous rain series in a high temporal resolution are essential. As the length of the rainfall records is often short, particularly the data available with the temporal and regional resolutions required for urban hydrology, it is necessary to find some numerical representation of the precipitation phenomenon to generate long synthetic rainfall series. An Alternating Renewal Model (ARM) is applied for this purpose, which consists of two structures: external and internal. The former is the sequence of wet and dry spells, described by their durations which are simulated stochastically. The internal structure is characterized by the amount of rain corresponding to each wet spell and its distribution within the spell. A multivariate frequency analysis is applied to analyze the internal structure of the wet spells and to generate synthetic events. The stochastic time series must reproduce the statistical characteristics of observed high resolution precipitation measurements used to generate them. The spatio-temporal interdependencies between stations are addressed by resampling the continuous synthetic series based on the Simulated Annealing (SA) procedure. The state of Lower-Saxony and surrounding areas, located in the north-west of Germany is used to develop the ARM. A total of 26 rainfall stations with high temporal resolution records, i.e. rainfall data every 5 minutes, are used to define the events, find the most suitable probability distributions, calibrate the corresponding parameters, simulate long synthetic series and evaluate the results. The length of the available data ranges from 10 to 20 years. The rainfall series involved in the different steps of calculation are compared using a rainfall-runoff model to simulate the runoff behavior in urban areas. The EPA Storm Water Management Model (SWMM) is applied for this evaluation. The results show a good representation of the

  5. Generating High-Temporal and Spatial Resolution TIR Image Data

    Science.gov (United States)

    Herrero-Huerta, M.; Lagüela, S.; Alfieri, S. M.; Menenti, M.

    2017-09-01

    Remote sensing imagery to monitor global biophysical dynamics requires the availability of thermal infrared data at high temporal and spatial resolution because of the rapid development of crops during the growing season and the fragmentation of most agricultural landscapes. Conversely, no single sensor meets these combined requirements. Data fusion approaches offer an alternative to exploit observations from multiple sensors, providing data sets with better properties. A novel spatio-temporal data fusion model based on constrained algorithms denoted as multisensor multiresolution technique (MMT) was developed and applied to generate TIR synthetic image data at both temporal and spatial high resolution. Firstly, an adaptive radiance model is applied based on spectral unmixing analysis of . TIR radiance data at TOA (top of atmosphere) collected by MODIS daily 1-km and Landsat - TIRS 16-day sampled at 30-m resolution are used to generate synthetic daily radiance images at TOA at 30-m spatial resolution. The next step consists of unmixing the 30 m (now lower resolution) images using the information about their pixel land-cover composition from co-registered images at higher spatial resolution. In our case study, TIR synthesized data were unmixed to the Sentinel 2 MSI with 10 m resolution. The constrained unmixing preserves all the available radiometric information of the 30 m images and involves the optimization of the number of land-cover classes and the size of the moving window for spatial unmixing. Results are still being evaluated, with particular attention for the quality of the data streams required to apply our approach.

  6. GENERATING HIGH-TEMPORAL AND SPATIAL RESOLUTION TIR IMAGE DATA

    Directory of Open Access Journals (Sweden)

    M. Herrero-Huerta

    2017-09-01

    Full Text Available Remote sensing imagery to monitor global biophysical dynamics requires the availability of thermal infrared data at high temporal and spatial resolution because of the rapid development of crops during the growing season and the fragmentation of most agricultural landscapes. Conversely, no single sensor meets these combined requirements. Data fusion approaches offer an alternative to exploit observations from multiple sensors, providing data sets with better properties. A novel spatio-temporal data fusion model based on constrained algorithms denoted as multisensor multiresolution technique (MMT was developed and applied to generate TIR synthetic image data at both temporal and spatial high resolution. Firstly, an adaptive radiance model is applied based on spectral unmixing analysis of . TIR radiance data at TOA (top of atmosphere collected by MODIS daily 1-km and Landsat – TIRS 16-day sampled at 30-m resolution are used to generate synthetic daily radiance images at TOA at 30-m spatial resolution. The next step consists of unmixing the 30 m (now lower resolution images using the information about their pixel land-cover composition from co-registered images at higher spatial resolution. In our case study, TIR synthesized data were unmixed to the Sentinel 2 MSI with 10 m resolution. The constrained unmixing preserves all the available radiometric information of the 30 m images and involves the optimization of the number of land-cover classes and the size of the moving window for spatial unmixing. Results are still being evaluated, with particular attention for the quality of the data streams required to apply our approach.

  7. High Atomic Number Contrast Media Offer Potential for Radiation Dose Reduction in Contrast-Enhanced Computed Tomography.

    Science.gov (United States)

    Roessler, Ann-Christin; Hupfer, Martin; Kolditz, Daniel; Jost, Gregor; Pietsch, Hubertus; Kalender, Willi A

    2016-04-01

    Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for further dose reduction using high-atomic-number elements such as hafnium and tungsten. As in previous studies, spectra were determined for which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) is minimized. We used 2 different quasi-anthropomorphic phantoms representing the liver cross-section of a normal adult and an obese adult patient with the lateral widths of 360 and 460 mm and anterior-posterior heights of 200 and 300 mm, respectively. We simulated and measured on 2 different scanners with x-ray spectra from 80 to 140 kV and from 70 to 150 kV, respectively. We determined the contrast for iodine-, hafnium-, and tungsten-based contrast media, the noise, and 3-dimensional dose distributions at all available tube voltages by measurements and by simulations. The dose-weighted CNR was determined as optimization parameter. Simulations and measurements were in good agreement regarding their dependence on energy for all parameters investigated. Hafnium provided the best performance for normal and for obese patient phantoms, indicating a dose reduction potential of 30% for normal and 50% for obese patients at 120 kV compared with iodine; this advantage increased further with higher kV values. Dose-weighted CNR values for tungsten were always slightly below the hafnium results. Iodine proved to be the superior choice at voltage values of 80 kV and below. Hafnium and tungsten both seem to be candidates for contrast-medium-enhanced CT of normal and obese adult patients with strongly reduced radiation dose at unimpaired image quality. Computed tomography examinations of obese patients will decrease in dose for higher kV values.

  8. High temporal frequency measurements of greenhouse gas emissions from soils

    Science.gov (United States)

    Savage, K.; Phillips, R.; Davidson, E.

    2014-05-01

    Carbon dioxide (CO2), methane (CH4), and nitrous oxide (N2O) are the most important anthropogenic greenhouse gases (GHGs). Variation in soil moisture can be very dynamic, and it is one of the dominant factors controlling the net exchange of these three GHGs. Although technologies for high-frequency, precise measurements of CO2 have been available for years, methods for measuring soil fluxes of CH4 and N2O at high temporal frequency have been hampered by lack of appropriate technology for in situ real-time measurements. A previously developed automated chamber system for measuring CO2 flux from soils was configured to run in line with a new quantum cascade laser (QCLAS) instrument that measures N2O and CH4. Here we present data from a forested wetland in Maine and an agricultural field in North Dakota, which provided examples of both net uptake and production for N2O and CH4. The objective was to provide a range of conditions in which to run the new system and to compare results to a traditional manual static-chamber method. The high-precision and more-than-10-times-lower minimum detectable flux of the QCLAS system, compared to the manual system, provided confidence in measurements of small N2O uptake in the forested wetland. At the agricultural field, the greatest difference between the automated and manual sampling systems came from the effect of the relatively infrequent manual sampling of the high spatial variation, or "hot spots", in GHG fluxes. Hot spots greatly influenced the seasonal estimates, particularly for N2O, over one 74-day alfalfa crop cycle. The high temporal frequency of the automated system clearly characterized the transient response of all three GHGs to precipitation and demonstrated a clear diel pattern related to temperature for GHGs. A combination of high-frequency automated and spatially distributed chambers would be ideal for characterizing hot spots and "hot moments" of GHG fluxes.

  9. High contrast ultrasound images of defects in food package seals.

    Science.gov (United States)

    Frazier, C H; Tian, Q; Ozguler, A; Morris, S A; O'Brien, W R

    2000-01-01

    Previous work to detect defects in food packaging seals using pulse-echo ultrasound inspired the backscattered amplitude integral (BAI) imaging technique, which could reliably identify channels with diameters 38 microm or larger at a center frequency of 17.3 MHz (lambda=86 microm). The current study presents two new processing techniques that more reliably reveal smaller channels ( approximately 6 microm in diameter). The RF sampling technique (RFS) displays a single, time-gated, pressure value from the received (not envelope-detected) RF waveform at each transducer position. The RF correlation technique (RFC) calculates the correlation coefficients of the RF signals with a reference signal that does not pass through a channel. The correlation coefficient can be calculated for the entire RF signal (RFCE) or over a short segment of the RF signal (RFCS). The performance of these imaging methods for detecting channel defects is investigated for plastic and aluminum foil trilaminate films with 6, 10, 15, 38, and 50 microm channels filled with water or air. Data are collected with a focused ultrasound transducer (17.3 MHz, 6.35 mm in diameter, f/2, 173 microm -6 dB pulse-echo lateral beamwidth at the focus) scanned over a rectangular grid, keeping the package in the focus. Performance is measured using detection rates, image contrast, and contrast-to-noise ratio (CNR). Both RFS and RFCS have improved detection rates relative to BAI for channels 15 microm or smaller. The RFCS technique is the most effective at smoothing the background, leading to the greatest CNR improvements.

  10. Modified point spread function for efficient high dynamic range LED backlight capable of high uniformity, high contrast, and smooth gradients.

    Science.gov (United States)

    Emmel, Jakob; Whitehead, Lorne A

    2013-12-01

    We investigate the effect of new point spread functions (PSFs) on the uniformity and contrast of high dynamic range displays that use local dimming of LEDs to yield a large dynamic range. A PSF shaped like a quadratic B-spline was hypothesized to create a uniform brightness backlight, as well as producing linear and quadratic gradients, while maintaining a very high contrast. We have found a practical optical structure to produce such a PSF, yielding a nonuniformity of only ±0.8%, while enabling a contrast ratio of 5∶1 and 33∶1 over distances of one and two unit cell spacings, respectively.

  11. Spatio-Temporal Variations of Marine Biofilm Communities Colonizing Artificial Substrata Including Antifouling Coatings in Contrasted French Coastal Environments.

    Science.gov (United States)

    Briand, Jean-François; Barani, Aude; Garnier, Cédric; Réhel, Karine; Urvois, Félix; LePoupon, Christophe; Bouchez, Agnès; Debroas, Didier; Bressy, Christine

    2017-10-01

    Surface colonization in seawater first corresponds to the selection of specific microbial biofilm communities. By coupling flow cytometry, microscopy and high throughput sequencing (HTS, 454 pyrosequencing) with artificial surfaces and environmental analyses, we intend to identify the contribution of biofilm community drivers at two contrasted French sites, one temperate and eutrophic (Lorient, Atlantic coast) and the other at a mesotrophic but highly contaminated bay (Toulon, North-Western Mediterranean Sea). Microbial communities were shaped by high temperatures, salinity and lead at Toulon by but nutrients and DOC at Lorient. Coatings including pyrithione exhibited a significant decrease of their microbial densities except for nanoeukaryotes. Clustering of communities was mainly based on the surface type and secondly the site, whereas seasons appeared of less importance. The in-depth HTS revealed that γ- and α-proteobacteria, but also Bacteroidetes, dominated highly diversified bacterial communities with a relative low β-diversity. Sensitivity to biocides released by the tested antifouling coatings could be noticed at different taxonomic levels: the percentage of Bacteroidetes overall decreased with the presence of pyrithione, whereas the α/γ-proteobacteria ratio decreased at Toulon when increased at Lorient. Small diatom cells (Amphora and Navicula spp.) dominated on all surfaces, whereas site-specific sub-dominant taxa appeared clearly more sensitive to biocides. This overall approach exhibited the critical significance of surface characteristics in biofilm community shaping.

  12. High-performance axicon lenses based on high-contrast, multilayer gratings

    Science.gov (United States)

    Doshay, Sage; Sell, David; Yang, Jianji; Yang, Rui; Fan, Jonathan A.

    2018-01-01

    Axicon lenses are versatile optical elements that can convert Gaussian beams to Bessel-like beams. In this letter, we demonstrate that axicons operating with high efficiencies and at large angles can be produced using high-contrast, multilayer gratings made from silicon. Efficient beam deflection of incident monochromatic light is enabled by higher-order optical modes in the silicon structure. Compared to diffractive devices made from low-contrast materials such as silicon dioxide, our multilayer devices have a relatively low spatial profile, reducing shadowing effects and enabling high efficiencies at large deflection angles. In addition, the feature sizes of these structures are relatively large, making the fabrication of near-infrared devices accessible with conventional optical lithography. Experimental lenses with deflection angles as large as 40° display field profiles that agree well with theory. Our concept can be used to design optical elements that produce higher-order Bessel-like beams, and the combination of high-contrast materials with multilayer architectures will more generally enable new classes of diffractive photonic structures.

  13. Transient analysis of electromagnetic wave interactions on high-contrast scatterers using volume electric field integral equation

    KAUST Repository

    Sayed, Sadeed Bin

    2014-07-01

    A marching on-in-time (MOT)-based time domain volume electric field integral equation (TD-VEFIE) solver is proposed for accurate and stable analysis of electromagnetic wave interactions on high-contrast scatterers. The stability is achieved using band-limited but two-sided (non-causal) temporal interpolation functions and an extrapolation scheme to cast the time marching into a causal form. The extrapolation scheme is designed to be highly accurate for oscillating and exponentially decaying fields, hence it accurately captures the physical behavior of the resonant modes that are excited inside the dielectric scatterer. Numerical results demonstrate that the resulting MOT scheme maintains its stability as the number of resonant modes increases with the contrast of the scatterer.

  14. Novel High Spatiotemporal Resolution Versus Standard-of-Care Dynamic Contrast-Enhanced Breast MRI: Comparison of Image Quality.

    Science.gov (United States)

    Morrison, Courtney K; Henze Bancroft, Leah C; DeMartini, Wendy B; Holmes, James H; Wang, Kang; Bosca, Ryan J; Korosec, Frank R; Strigel, Roberta M

    2017-04-01

    Currently, dynamic contrast-enhanced (DCE) breast magnetic resonance imaging (MRI) prioritizes spatial resolution over temporal resolution given the limitations of acquisition techniques. The purpose of our intrapatient study was to assess the ability of a novel high spatial and high temporal resolution DCE breast MRI method to maintain image quality compared with the clinical standard-of-care (SOC) MRI. Thirty patients, each demonstrating a focal area of enhancement (29 benign, 1 cancer) on their SOC MRI, consented to undergo a research DCE breast MRI on a second date. For the research DCE MRI, a method (DIfferential Subsampling with Cartesian Ordering [DISCO]) using pseudorandom k-space sampling, view sharing reconstruction, 2-point Dixon fat-water separation, and parallel imaging was used to produce images with an effective temporal resolution 6 times faster than the SOC MRI (27 vs 168 seconds, respectively). Both the SOC and DISCO MRI scans were acquired with matching spatial resolutions of 0.8 × 0.8 × 1.6 mm. Image quality (distortion/artifacts, resolution, fat suppression, lesion conspicuity, perceived signal-to-noise ratio, and overall image quality) was scored by 3 radiologists in a blinded reader study. Differences in image quality scores between the DISCO and SOC images were all less than 0.8 on a 10-point scale, and both methods were assessed as providing diagnostic image quality in all cases. DISCO images with the same high spatial resolution, but 6 times the effective temporal resolution as the SOC MRI scans, were produced, yielding 20 postcontrast time points with DISCO compared with 3 for the SOC MRI, over the same total time interval. DISCO provided comparable image quality compared with the SOC MRI, while also providing 6 times faster effective temporal resolution and the same high spatial resolution.

  15. Co-production of contrastive prosodic focus and manual gestures : temporal coordination and effects on the acoustic and articulatory correlates of focus

    OpenAIRE

    Roustan, Benjamin; Dohen, Marion

    2010-01-01

    International audience; Speech, and prosody in particular, is tightly linked to manual gestures. This study investigates the coordination of prosodic contrastive focus and different manual gestures (pointing, beat and control gestures). We used motion capture on ten speakers to explore this issue. The results show that prosodic focus "attracts" the manual gesture whichever its type, the temporal alignment being stricter for pointing and mainly realized between the apex of the pointing gesture...

  16. High functional load inhibits phonological contrast loss: a corpus study.

    Science.gov (United States)

    Wedel, Andrew; Kaplan, Abby; Jackson, Scott

    2013-08-01

    For nearly a century, linguists have suggested that diachronic merger is less likely between phonemes with a high functional load--that is, phonemes that distinguish many words in the language in question. However, limitations in data and computational power have made assessing this hypothesis difficult. Here we present the first larger-scale study of the functional load hypothesis, using data from sound changes in a diverse set of languages. Our results support the functional load hypothesis: phoneme pairs undergoing merger distinguish significantly fewer minimal pairs in the lexicon than unmerged phoneme pairs. Furthermore, we show that higher phoneme probability is positively correlated with merger, but that this effect is stronger for phonemes that distinguish no minimal pairs. Finally, within our dataset we find that minimal pair count and phoneme probability better predict merger than change in system entropy at the lexical or phoneme level. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. High spatiotemporal resolution measurement of regional lung air volumes from 2D phase contrast x-ray images

    Energy Technology Data Exchange (ETDEWEB)

    Leong, Andrew F. T.; Islam, M. Sirajul; Kitchen, Marcus J. [School of Physics, Monash University, Victoria 3800 (Australia); Fouras, Andreas [Division of Biological Engineering, Monash University, Victoria 3800 (Australia); Wallace, Megan J.; Hooper, Stuart B. [Ritchie Centre and Department of Obstetrics and Gynaecology, Monash Institute of Medical Research, Monash University, Victoria 3168 (Australia)

    2013-04-15

    Purpose: Described herein is a new technique for measuring regional lung air volumes from two-dimensional propagation-based phase contrast x-ray (PBI) images at very high spatial and temporal resolution. Phase contrast dramatically increases lung visibility and the outlined volumetric reconstruction technique quantifies dynamic changes in respiratory function. These methods can be used for assessing pulmonary disease and injury and for optimizing mechanical ventilation techniques for preterm infants using animal models. Methods: The volumetric reconstruction combines the algorithms of temporal subtraction and single image phase retrieval (SIPR) to isolate the image of the lungs from the thoracic cage in order to measure regional lung air volumes. The SIPR algorithm was used to recover the change in projected thickness of the lungs on a pixel-by-pixel basis (pixel dimensions {approx}16.2 {mu}m). The technique has been validated using numerical simulation and compared results of measuring regional lung air volumes with and without the use of temporal subtraction for removing the thoracic cage. To test this approach, a series of PBI images of newborn rabbit pups mechanically ventilated at different frequencies was employed. Results: Regional lung air volumes measured from PBI images of newborn rabbit pups showed on average an improvement of at least 20% in 16% of pixels within the lungs in comparison to that measured without the use of temporal subtraction. The majority of pixels that showed an improvement was found to be in regions occupied by bone. Applying the volumetric technique to sequences of PBI images of newborn rabbit pups, it is shown that lung aeration at birth can be highly heterogeneous. Conclusions: This paper presents an image segmentation technique based on temporal subtraction that has successfully been used to isolate the lungs from PBI chest images, allowing the change in lung air volume to be measured over regions as small as the pixel size. Using

  18. Improvements on Fresnel arrays for high contrast imaging

    Science.gov (United States)

    Wilhem, Roux; Laurent, Koechlin

    2018-01-01

    The Fresnel Diffractive Array Imager (FDAI) is based on a new optical concept for space telescopes, developed at Institut de Recherche en Astrophysique et Planétologie (IRAP), Toulouse, France. For the visible and near-infrared it has already proven its performances in resolution and dynamic range. We propose it now for astrophysical applications in the ultraviolet with apertures from 6 to 30 meters, aimed at imaging in UV faint astrophysical sources close to bright ones, as well as other applications requiring high dynamic range. Of course the project needs first a probatory mission at small aperture to validate the concept in space. In collaboration with institutes in Spain and Russia, we will propose to board a small prototype of Fresnel imager on the International Space Station (ISS), with a program combining technical tests and astrophysical targets. The spectral domain should contain the Lyman-α line (λ = 121 nm). As part of its preparation, we improve the Fresnel array design for a better Point Spread Function in UV, presently on a small laboratory prototype working at 260 nm. Moreover, we plan to validate a new optical design and chromatic correction adapted to UV. In this article we present the results of numerical propagations showing the improvement in dynamic range obtained by combining and adapting three methods : central obturation, optimization of the bars mesh holding the Fresnel rings, and orthogonal apodization. We briefly present the proposed astrophysical program of a probatory mission with such UV optics.

  19. High Resolution Spatial and Temporal Mapping of Traffic-Related Air Pollutants

    Directory of Open Access Journals (Sweden)

    Stuart Batterman

    2015-04-01

    Full Text Available Vehicle traffic is one of the most significant emission sources of air pollutants in urban areas. While the influence of mobile source emissions is felt throughout an urban area, concentrations from mobile emissions can be highest near major roadways. At present, information regarding the spatial and temporal patterns and the share of pollution attributable to traffic-related air pollutants is limited, in part due to concentrations that fall sharply with distance from roadways, as well as the few monitoring sites available in cities. This study uses a newly developed dispersion model (RLINE and a spatially and temporally resolved emissions inventory to predict hourly PM2.5 and NOx concentrations across Detroit (MI, USA at very high spatial resolution. Results for annual averages and high pollution days show contrasting patterns, the need for spatially resolved analyses, and the limitations of surrogate metrics like proximity or distance to roads. Data requirements, computational and modeling issues are discussed. High resolution pollutant data enable the identification of pollutant “hotspots”, “project-level” analyses of transportation options, development of exposure measures for epidemiology studies, delineation of vulnerable and susceptible populations, policy analyses examining risks and benefits of mitigation options, and the development of sustainability indicators integrating environmental, social, economic and health information.

  20. Coronary computed tomography angiography - Tolerability of β-blockers and contrast media, and temporal changes in radiation dose

    DEFF Research Database (Denmark)

    Pedersen, Charlotte; Thomsen, Camilla F; Hosbond, Susanne Elisabeth

    2014-01-01

    Abstract Objective: To determine the risk of administration of β-blockers, contrast induced nephropathy (CIN) and trend in x-rays use, during coronary computed tomography angiography (CCTA). Methods: A total of 416 patients were referred for elective CCTA. To achieve a resting heart rate below 60.......0001. Conclusions: In terms of side effects to β-blockers and contrast media, there were no short term complications to CCTA. Furthermore the radiation dose was dramatically diminished over the last three years....

  1. Combining high-dispersion spectroscopy with high contrast imaging: Probing rocky planets around our nearest neighbors

    Science.gov (United States)

    Snellen, I.; de Kok, R.; Birkby, J. L.; Brandl, B.; Brogi, M.; Keller, C.; Kenworthy, M.; Schwarz, H.; Stuik, R.

    2015-04-01

    Context. Ground-based high-dispersion (R ~ 100 000) spectroscopy (HDS) is proving to be a powerful technique with which to characterize extrasolar planets. The planet signal is distilled from the bright starlight, combining ral and time-differential filtering techniques. In parallel, high-contrast imaging (HCI) is developing rapidly, aimed at spatially separating the planet from the star. While HDS is limited by the overwhelming noise from the host star, HCI is limited by residual quasi-static speckles. Both techniques currently reach planet-star contrast limits down to ~10-5, albeit for very different types of planetary systems. Aims: In this work, we discuss a way to combine HDS and HCI (HDS+HCI). For a planet located at a resolvable angular distance from its host star, the starlight can be reduced up to several orders of magnitude using adaptive optics and/or coronography. In addition, the remaining starlight can be filtered out using high-dispersion spectroscopy, utilizing the significantly different (or Doppler shifted) high-dispersion spectra of the planet and star. In this way, HDS+HCI can in principle reach contrast limits of ~10-5 × 10-5, although in practice this will be limited by photon noise and/or sky-background. In contrast to current direct imaging techniques, such as Angular Differential Imaging and Spectral Differential Imaging, it will work well at small working angles and is much less sensitive to speckle noise. For the discovery of previously unknown planets HDS+HCI requires a high-contrast adaptive optics system combined with a high-dispersion R ~ 100 000 integral field spectrograph (IFS). This combination currently does not exist, but is planned for the European Extremely Large Telescope. Methods: We present simulations of HDS+HCI observations with the E-ELT, both probing thermal emission from a planet at infrared wavelengths, and starlight reflected off a planet atmosphere at optical wavelengths. For the infrared simulations we use the

  2. Temporal changes in greenspace in a highly urbanized region.

    Science.gov (United States)

    Dallimer, Martin; Tang, Zhiyao; Bibby, Peter R; Brindley, Paul; Gaston, Kevin J; Davies, Zoe G

    2011-10-23

    The majority of the world's population now lives in towns and cities, and urban areas are expanding faster than any other land-use type. In response to this phenomenon, two opposing arguments have emerged: whether cities should 'sprawl' into the wider countryside, or 'densify' through the development of existing urban greenspace. However, these greenspaces are increasingly recognized as being central to the amelioration of urban living conditions, supporting biodiversity conservation and ecosystem service provision. Taking the highly urbanized region of England as a case study, we use data from a variety of sources to investigate the impact of national-level planning policy on temporal patterns in the extent of greenspace in cities. Between 1991 and 2006, greenspace showed a net increase in all but one of 13 cities. However, the majority of this gain occurred prior to 2001, and greenspace has subsequently declined in nine cities. Such a dramatic shift in land use coincides with policy reforms in 2000, which favoured densification. Here, we illustrate the dynamic and policy-responsive nature of urban land use, thereby highlighting the need for a detailed investigation of the trade-offs associated with different mechanisms of urban densification to optimize and secure the diverse benefits associated with greenspaces.

  3. Continuously tunable photonic fractional Hilbert transformer using a high-contrast germanium-doped silica-on-silicon microring resonator.

    Science.gov (United States)

    Shahoei, Hiva; Dumais, Patrick; Yao, Jianping

    2014-05-01

    We propose and experimentally demonstrate a continuously tunable fractional Hilbert transformer (FHT) based on a high-contrast germanium-doped silica-on-silicon (SOS) microring resonator (MRR). The propagation loss of a high-contrast germanium-doped SOS waveguide can be very small (0.02 dB/cm) while the lossless bend radius can be less than 1 mm. These characteristics lead to the fabrication of an MRR with a high Q-factor and a large free-spectral range (FSR), which is needed to implement a Hilbert transformer (HT). The SOS MRR is strongly polarization dependent. By changing the polarization direction of the input signal, the phase shift introduced at the center of the resonance spectrum is changed. The tunable phase shift at the resonance wavelength can be used to implement a tunable FHT. A germanium-doped SOS MRR with a high-index contrast of 3.8% is fabricated. The use of the fabricated MRR for the implementation of a tunable FHT with tunable orders at 1, 0.85, 0.95, 1.05, and 1.13 for a Gaussian pulse with the temporal full width at half-maximum of 80 ps is experimentally demonstrated.

  4. Multiplatform observations enabling albedo retrievals with high temporal resolution

    Science.gov (United States)

    Riihelä, Aku; Manninen, Terhikki; Key, Jeffrey; Sun, Qingsong; Sütterlin, Melanie; Lattanzio, Alessio; Schaaf, Crystal

    2017-04-01

    In this paper we show that combining observations from different polar orbiting satellite families (such as AVHRR and MODIS) is physically justifiable and technically feasible. Our proposed approach will lead to surface albedo retrievals at higher temporal resolution than the state of the art, with comparable or better accuracy. This study is carried out in the World Meteorological Organization (WMO) Sustained and coordinated processing of Environmental Satellite data for Climate Monitoring (SCOPE-CM) project SCM-02 (http://www.scope-cm.org/projects/scm-02/). Following a spectral homogenization of the Top-of-Atmosphere reflectances of bands 1 & 2 from AVHRR and MODIS, both observation datasets are atmospherically corrected with a coherent atmospheric profile and algorithm. The resulting surface reflectances are then fed into an inversion of the RossThick-LiSparse-Reciprocal surface bidirectional reflectance distribution function (BRDF) model. The results of the inversion (BRDF kernels) may then be integrated to estimate various surface albedo quantities. A key principle here is that the larger number of valid surface observations with multiple satellites allows us to invert the BRDF coefficients within a shorter time span, enabling the monitoring of relatively rapid surface phenomena such as snowmelt. The proposed multiplatform approach is expected to bring benefits in particular to the observation of the albedo of the polar regions, where persistent cloudiness and long atmospheric path lengths present challenges to satellite-based retrievals. Following a similar logic, the retrievals over tropical regions with high cloudiness should also benefit from the method. We present results from a demonstrator dataset of a global combined AVHRR-GAC and MODIS dataset covering the year 2010. The retrieved surface albedo is compared against quality-monitored in situ albedo observations from the Baseline Surface Radiation Network (BSRN). Additionally, the combined retrieval

  5. Imaging of vaporised sub-micron phase change contrast agents with high frame rate ultrasound and optics.

    Science.gov (United States)

    Lin, Shengtao; Zhang, Ge; Jamburidze, Akaki; Chee, Melisse; Leow, Chee Hau; Garbin, Valeria; Tang, Meng-Xing

    2018-01-31

    Phase-change ultrasound contrast agent (PCCA), or nanodroplet shows promises as an alternative to conventional microbubble agent over a wide range of diagnostic applications. In the meantime, high-frame-rate (HFR) ultrasound imaging with microbubbles enables unprecedentedly temporal resolution compared to traditional contrast-enhanced ultrasound imaging. The combination of HFR ultrasound imaging and PCCAs can offer opportunities to observe and better understand PCCA behaviour after vaporisation capturing the fast phenomenon at a high temporal resolution. In this study, we utilised HFR ultrasound at frame rates in the kilohertz range (5-20 kHz) to image the native and size-selected PCCA populations immediately after vaporisation in vitro with clinical acoustic parameters. The size-selected PCCAs through filtration are shown to preserve submicron-sized (mean diameter < 200 nm) population without micron-sized outliers (> 1 µm) that are originally from the native PCCA emulsion. The results demonstrate imaging signals with different amplitude and temporal features compared to that of microbubbles. Compared with microbubbles, both B-mode and Pulse-Inversion (PI) signals from vaporised PCCA populations were reduced significantly in the first tens of milliseconds, while only B-mode signals from the PCCAs recovered during the next 400 ms, suggesting significant changes to the size distribution of PCCAs after vaporisation. It is also shown that such recovery in signal over time is not evident when using size-selective PCCAs. Furthermore, it was found that signals from the vaporised PCCA populations are affected by the amplitude and frame rate of the HFR ultrasound imaging. Using high-speed optical camera observation (30 kHz), we observed the particle size change in the vaporised PCCA populations exposed to the HFR ultrasound imaging pulses. These findings can benefit the understandings of PCCA behaviour under HFR ultrasound imaging. © 2018 Institute of Physics and

  6. Dynamic full field optical coherence tomography: subcellular metabolic contrast revealed in tissues by temporal analysis of interferometric signals

    CERN Document Server

    Apelian, Clement; Thouvenin, Olivier; Boccara, A Claude

    2016-01-01

    We developed a new endogenous approach to reveal subcellular metabolic contrast in fresh ex vivo tissues taking advantage of the time dependence of the full field optical coherence tomography interferometric signals. This method reveals signals linked with local activity of the endogenous scattering elements which can reveal cells where other imaging techniques fail or need exogenous contrast agents. We benefit from the micrometric transverse resolution of full field OCT to image intracellular features. We used this time dependence to identify different dynamics at the millisecond scale on a wide range of organs in normal or pathological conditions.

  7. Relationship between size summation properties, contrast sensitivity and response latency in the dorsomedial and middle temporal areas of the primate extrastriate cortex.

    Directory of Open Access Journals (Sweden)

    Leo L Lui

    Full Text Available Analysis of the physiological properties of single neurons in visual cortex has demonstrated that both the extent of their receptive fields and the latency of their responses depend on stimulus contrast. Here, we explore the question of whether there are also systematic relationships between these response properties across different cells in a neuronal population. Single unit recordings were obtained from the middle temporal (MT and dorsomedial (DM extrastriate areas of anaesthetized marmoset monkeys. For each cell, spatial integration properties (length and width summation, as well as the presence of end- and side-inhibition within 15° of the receptive field centre were determined using gratings of optimal direction of motion and spatial and temporal frequencies, at 60% contrast. Following this, contrast sensitivity was assessed using gratings of near-optimal length and width. In both areas, we found a relationship between spatial integration and contrast sensitivity properties: cells that summated over smaller areas of the visual field, and cells that displayed response inhibition at larger stimulus sizes, tended to show higher contrast sensitivity. In a sample of MT neurons, we found that cells showing longer latency responses also tended to summate over larger expanses of visual space in comparison with neurons that had shorter latencies. In addition, longer-latency neurons also tended to show less obvious surround inhibition. Interestingly, all of these effects were stronger and more consistent with respect to the selectivity for stimulus width and strength of side-inhibition than for length selectivity and end-inhibition. The results are partially consistent with a hierarchical model whereby more extensive receptive fields require convergence of information from larger pools of "feedforward" afferent neurons to reach near-optimal responses. They also suggest that a common gain normalization mechanism within MT and DM is involved, the

  8. Multivalent, high-relaxivity MRI contrast agents using rigid cysteine-reactive gadolinium complexes.

    Science.gov (United States)

    Garimella, Praveena D; Datta, Ankona; Romanini, Dante W; Raymond, Kenneth N; Francis, Matthew B

    2011-09-21

    MRI contrast agents providing very high relaxivity values can be obtained through the attachment of multiple gadolinium(III) complexes to the interior surfaces of genome-free viral capsids. In previous studies, the contrast enhancement was predicted to depend on the rigidity of the linker attaching the MRI agents to the protein surface. To test this hypothesis, a new set of Gd-hydroxypyridonate based MRI agents was prepared and attached to genetically introduced cysteine residues through flexible and rigid linkers. Greater contrast enhancements were seen for MRI agents that were attached via rigid linkers, validating the design concept and outlining a path for future improvements of nanoscale MRI contrast agents.

  9. The Effect of Attention on Neuronal Responses to High and Low Contrast Stimuli

    Science.gov (United States)

    Lee, Joonyeol

    2010-01-01

    It remains unclear how attention affects the tuning of individual neurons in visual cerebral cortex. Some observations suggest that attention preferentially enhances responses to low contrast stimuli, whereas others suggest that attention proportionally affects responses to all stimuli. Resolving how attention affects responses to different stimuli is essential for understanding the mechanism by which it acts. To explore the effects of attention on stimuli of different contrasts, we recorded from individual neurons in the middle temporal visual area (MT) of rhesus monkeys while shifting their attention between preferred and nonpreferred stimuli within their receptive fields. This configuration results in robust attentional modulation that makes it possible to readily distinguish whether attention acts preferentially on low contrast stimuli. We found no evidence for greater enhancement of low contrast stimuli. Instead, the strong attentional modulations were well explained by a model in which attention proportionally enhances responses to stimuli of all contrasts. These data, together with observations on the effects of attention on responses to other stimulus dimensions, suggest that the primary effect of attention in visual cortex may be to simply increase the strength of responses to all stimuli by the same proportion. PMID:20538780

  10. Tunable VCSEL with ultra-thin high contrast grating for high-speed tuning.

    Science.gov (United States)

    Zhou, Ye; Huang, Michael C; Chang-Hasnain, Connie J

    2008-09-01

    We report a nano-electromechanical optoelectronic (NEMO) tunable vertical-cavity surface-emitting laser (VCSEL) with an ultra-thin (145 nm) electrostatically actuated high-index-contrast subwavelength grating (HCG) designed to strongly reflect TE-polarized light. Single mode emission (SMSR >45 dB) and continuous wavelength tuning (approximately 4 nm) were obtained at room temperature with output power up to 2 mW under continuous wave (CW) operation. A record short wavelength tuning time (approximately 90 ns) is experimentally demonstrated, which is >100 times faster than previously reported DBR-based tunable VCSELs and a 1.7 times improvement over the previously reported TM polarized NEMO tunable VCSELs.

  11. Coronary computed tomography angiography - tolerability of β-blockers and contrast media, and temporal changes in radiation dose.

    Science.gov (United States)

    Pedersen, Charlotte; Thomsen, Camilla F; Hosbond, Susanne E; Thomassen, Anders; Mickley, Hans; Diederichsen, Axel C P

    2014-10-01

    To determine the risk in administering β-blockers, contrast-induced nephropathy (CIN) and the trend in X-ray use, during coronary computed tomography angiography (CCTA). A total of 416 patients were referred for elective CCTA. To achieve a resting heart rate below 60 beats per minute, oral and/or intravenous β-blockers were administered. Using questionnaires, information on the adverse effects of β-blockers was collected from the patients. The levels of s-creatinine and estimated GFR (eGFR) were measured before and after contrast enhanced CCTA. Radiation exposure was compared with the exposure 3 years earlier. There was no significant difference in the symptoms (dizziness, lipothymia and palpitations) between patients with and patients without β-blocker pretreatment. Compared to baseline values, the decrease in s-creatinine was not significant (75.2 vs. 74.6 μmol/L, p = 0.09), while the increase in eGFR was not significant (78 vs. 79 mL/min, p = 0.17). Also, subgroups of patients with hypertension, hypercholesterolemia, diabetes or pre-existing slight impairment in renal function did not develop CIN. The mean radiation exposure decreased from 17.5 to 6.7 mSv, p < 0.0001. In terms of the side effects of β-blockers and contrast media, there were no short term complications to CCTA. Furthermore, the radiation dose has been dramatically diminished over the last three years.

  12. Fat suppression techniques for obtaining high resolution dynamic contrast enhanced bilateral breast MR images at 7T.

    Science.gov (United States)

    van der Velden, Tijl A; Schmitz, Alexander M Th; Gilhuijs, Kenneth G A; Veldhuis, Wouter B; Luijten, Peter R; Boer, Vincent O; Klomp, Dennis W J

    2016-05-01

    To compare water selective excitation (WSE) and Dixon fat suppression in the context of high-resolution dynamic contrast enhanced MRI of the breast at 7T. Ten healthy volunteers and one patient with a malignant breast lesion were scanned at 7T. The MRI protocol contained 3D T1-weighted gradient echo images obtained with both WSE fat suppression, multi echo Dixon fat suppression, and without fat suppression. Images were acquired at a (0.8mm)(3) or (0.7mm)(3) isotropic resolution with equal field of view and optimized such to obtain a maximal SNR. Image quality was scored qualitatively on overall image quality, sharpness of anatomical details, presence of artifacts, inhomogeneous fat suppression and the presence of water-fat shift. A quantitative scoring was obtained from the signal to noise ratio and contrast to noise ratio. WSE scored significantly better in terms of overall image quality and the absence of artifacts. No significant difference in contrast to noise ratio was found between the two fat suppression methods. When maximizing temporal and spatial resolution of high resolution DCE MRI of the breast, water selective excitation provides better image quality than multi echo Dixon at 7T. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Towards Ultra-High Q Microresonators in High-Index Contrast AlGaAs-On-Insulator

    DEFF Research Database (Denmark)

    Pu, Minhao; Kamel, Ayman Nassar; Stassen, Erik

    2017-01-01

    We demonstrate an AlGaAs-on-insulator microresonator with intrinsic Q as high as 690,000. We optimized the fabrication and investigated the impact of waveguide dimension on the Q in such a high-index contrast platform.......We demonstrate an AlGaAs-on-insulator microresonator with intrinsic Q as high as 690,000. We optimized the fabrication and investigated the impact of waveguide dimension on the Q in such a high-index contrast platform....

  14. Temporal dynamics of high repetition rate pulsed single longitudinal ...

    Indian Academy of Sciences (India)

    tion dynamics closely affects both spectral and temporal behaviour of the dye laser. The frequency chirp of the dye laser during the evolution due to pulsation of population is studied for our cavity and the results are presented. 2. Experimental method. Figure 1 shows the schematic of the single longitudinal mode (SLM) dye ...

  15. High-Contrast Coronagraph Performance in the Presence of DM Actuator Defects

    Science.gov (United States)

    Sidick, Erkin; Shaklan, Stuart; Cady, Eric

    2015-01-01

    Deformable Mirrors (DMs) are critical elements in high contrast coronagraphs, requiring precision and stability measured in picometers to enable detection of Earth-like exoplanets. Occasionally DM actuators or their associated cables or electronics fail, requiring a wavefront control algorithm to compensate for actuators that may be displaced from their neighbors by hundreds of nanometers. We have carried out experiments on our High-Contrast Imaging Testbed (HCIT) to study the impact of failed actuators in partial fulfillment of the Terrestrial Planet Finder Coronagraph optical model validation milestone. We show that the wavefront control algorithm adapts to several broken actuators and maintains dark-hole contrast in broadband light.

  16. Temporal patterns of ant diversity across a mountain with climatically contrasting aspects in the tropics of Africa.

    Directory of Open Access Journals (Sweden)

    Thinandavha Caswell Munyai

    Full Text Available Factors that drive species richness over space and time are still poorly understood and are often context specific. Identifying these drivers for ant diversity has become particularly relevant within the context of contemporary global change events. We report on a long-term bi-annual (wet and dry seasons, standardized sampling of epigeal ants over a five year period on the mesic and arid aspects of an inselberg (Soutpansberg Mountain Range in the tropics of Africa. We detail seasonal, annual and long-term trends of species density, test the relative contribution of geometric constraints, energy, available area, climate, local environmental variables, time, and space in explaining ant species density patterns through Generalized Linear Mixed Models (GLMM where replicates were included as random factors to account for temporal pseudo-replication. Seasonal patterns were very variable and we found evidence of decreased seasonal variation in species density with increased elevation. The extent and significance of a decrease in species density with increased elevation varied with season. Annual patterns point to an increase in ant diversity over time. Ant density patterns were positively correlated with mean monthly temperature but geometric constraints dominated model performance while soil characteristics were minor correlates. These drivers and correlates accounted for all the spatio-temporal variability in the database. Ant diversity was therefore mainly determined by geometric constraints and temperature while soil characteristics (clay and carbon content accounted for smaller but significant amounts of variation. This study documents the role of season, elevation and their interaction in affecting ant species densities while highlighting the importance of neutral processes and temperature in driving these patterns.

  17. Temporal patterns of ant diversity across a mountain with climatically contrasting aspects in the tropics of Africa.

    Science.gov (United States)

    Munyai, Thinandavha Caswell; Foord, Stefan Hendrik

    2015-01-01

    Factors that drive species richness over space and time are still poorly understood and are often context specific. Identifying these drivers for ant diversity has become particularly relevant within the context of contemporary global change events. We report on a long-term bi-annual (wet and dry seasons), standardized sampling of epigeal ants over a five year period on the mesic and arid aspects of an inselberg (Soutpansberg Mountain Range) in the tropics of Africa. We detail seasonal, annual and long-term trends of species density, test the relative contribution of geometric constraints, energy, available area, climate, local environmental variables, time, and space in explaining ant species density patterns through Generalized Linear Mixed Models (GLMM) where replicates were included as random factors to account for temporal pseudo-replication. Seasonal patterns were very variable and we found evidence of decreased seasonal variation in species density with increased elevation. The extent and significance of a decrease in species density with increased elevation varied with season. Annual patterns point to an increase in ant diversity over time. Ant density patterns were positively correlated with mean monthly temperature but geometric constraints dominated model performance while soil characteristics were minor correlates. These drivers and correlates accounted for all the spatio-temporal variability in the database. Ant diversity was therefore mainly determined by geometric constraints and temperature while soil characteristics (clay and carbon content) accounted for smaller but significant amounts of variation. This study documents the role of season, elevation and their interaction in affecting ant species densities while highlighting the importance of neutral processes and temperature in driving these patterns.

  18. Techniques for High Contrast Imaging in Multi-Star Systems II: Multi-Star Wavefront Control

    Science.gov (United States)

    Sirbu, D.; Thomas, S.; Belikov, R.

    2017-01-01

    Direct imaging of exoplanets represents a challenge for astronomical instrumentation due to the high-contrast ratio and small angular separation between the host star and the faint planet. Multi-star systems pose additional challenges for coronagraphic instruments because of the diffraction and aberration leakage introduced by the additional stars, and as a result are not planned to be on direct imaging target lists. Multi-star wavefront control (MSWC) is a technique that uses a coronagraphic instrument's deformable mirror (DM) to create high-contrast regions in the focal plane in the presence of multiple stars. Our previous paper introduced the Super-Nyquist Wavefront Control (SNWC) technique that uses a diffraction grating to enable the DM to generate high-contrast regions beyond the nominal controllable region. These two techniques can be combined to generate high-contrast regions for multi-star systems at any angular separations. As a case study, a high-contrast wavefront control (WC) simulation that applies these techniques shows that the habitable region of the Alpha Centauri system can be imaged reaching 8 times 10(exp -9) mean contrast in 10 percent broadband light in one-sided dark holes from 1.6-5.5 lambda (wavelength) divided by D (distance).

  19. High Spatio-Temporal-Resolution Detection of Chlorophyll Fluorescence Dynamics from a Single Chloroplast with Confocal Imaging Fluorometer

    CERN Document Server

    Tseng, Yi-Chin

    2016-01-01

    Chlorophyll fluorescence (CF) is a key indicator to study plant physiology or photosynthesis efficiency. Conventionally, CF is characterized by fluorometers, which only allows ensemble measurement through wide-field detection. For imaging fluorometers, the typical spatial and temporal resolutions are on the order of millimeter and second, far from enough to study cellular/sub-cellular CF dynamics. In addition, due to the lack of optical sectioning capability, conventional imaging fluorometers cannot identify CF from a single cell or even a single chloroplast. Here we demonstrated a novel fluorometer based on confocal imaging, that not only provides high contrast images, but also allows CF measurement with spatiotemporal resolution as high as micrometer and millisecond. CF transient (the Kautsky curve) from a single chloroplast is successfully obtained, with both the temporal dynamics and the intensity dependences corresponding well to the ensemble measurement from conventional studies. The significance of con...

  20. Comparison between high- and zero-contrast gratings as VCSEL mirrors

    Science.gov (United States)

    Liu, Anjin; Zheng, Wanhua; Bimberg, Dieter

    2017-04-01

    This study presents a comparison between high-contrast gratings (HCGs) and zero-contrast gratings (ZCGs) for high-speed vertical-cavity surface-emitting lasers (VCSELs). Both types of gratings exhibit high reflectivities beyond 99.5% due to the destructive interference at the output plane, but the HCG has a broader high reflectivity band. The HCG has a lower reflection delay time and smaller energy penetration length than the ZCG. The HCG has poorer mode selectivity for the VCSEL than the ZCG. The fabrication of the ZCG is less complex but with tight fabrication tolerances.

  1. High-Index Contrast Silicon Rich Silicon Nitride Optical Waveguides and Devices

    DEFF Research Database (Denmark)

    Philipp, Hugh Taylor

    2004-01-01

    This research focused on the realization of high-density integrated optical devices made with high-index contrast waveguides. The material platform used for to develop these devices was modeled after standard silicon on silicon technology. The high-index waveguide core material was silicon rich...... silicon nitride. This provided a sharp contrast with silica and made low-loss waveguide bending radii less than 25mm possible. An immediate consequence of such small bending radii is the ability to make practical ring resonator based devices with a large free spectral range. Several ring resonator based...... devices have been demonstrated. Directly UV-written waveguides have also been used with high-index contrast ring resonators to make hybrid devices. These hybrid devices are interesting because of the possibility of making practical low insertion-loss devices that utilize the benefits of a high...

  2. Efficient multi-keV X-ray generation from high-contrast laser plasma interaction

    Directory of Open Access Journals (Sweden)

    Zhang Z.

    2013-11-01

    Full Text Available Kα line emission from Mo was experimentally and theoretically studied using clean, ultrahigh-intensity femtosecond laser pulses. The absolute yields of Kα x-rays at 17 keV from Mo were measured as a function of the laser pulse contrast ratio and irradiation intensity. Significantly enhanced Kα yields were obtained by employing high contrast ratio at optimum irradiance. Conversion efficiencies of 4.28 × 10−5/sr, the highest values obtained to date, was demonstrated with contrast ratios in the range of 10−10 to 10−11.

  3. High-resolution cell outline segmentation and tracking from phase-contrast microscopy images

    OpenAIRE

    Ambühl, Mark; Brepsant, C.; Meister, Jean-Jacques; Verkhovsky, Alexander; Sbalzarini, I. F.

    2012-01-01

    Accurate extraction of cell outlines from microscopy images is essential for analysing the dynamics of migrating cells. Phase-contrast microscopy is one of the most common and convenient imaging modalities for observing cell motility because it does not require exogenous labelling and uses only moderate light levels with generally negligible phototoxicity effects. Automatic extraction and tracking of high-resolution cell outlines from phase-contrast images, however, is difficult due to comple...

  4. The LBTI Fizeau imager - I. Fundamental gain in high-contrast imaging

    Science.gov (United States)

    Patru, F.; Esposito, S.; Puglisi, A.; Riccardi, A.; Pinna, E.; Arcidiacono, C.; Antichi, J.; Mennesson, B.; Defrère, D.; Hinz, P. M.; Hill, J. M.

    2017-12-01

    We show by numerical simulations a fundamental gain in contrast when combining coherently monochromatic light from two adaptive optics (AO) telescopes instead of using a single stand-alone AO telescope, assuming efficient control and acquisition systems at high speed. A contrast gain map is defined as the normalized point spread functions (PSFs) ratio of a single Large Binocular Telescope (LBT) aperture over the dual Large Binocular Telescope Interferometer (LBTI) aperture in Fizeau mode. The global gain averaged across the AO-corrected field of view is improved by a factor of 2 in contrast in long exposures and by a factor of 10 in contrast in short exposures (i.e. in exposures, respectively, longer or shorter than the coherence time). The fringed speckle halo in short exposures contains not only high-angular resolution information, as stated by speckle imaging and speckle interferometry, but also high-contrast imaging information. A high-gain zone is further produced in the valleys of the PSF formed by the dark Airy rings and/or the dark fringes. Earth rotation allows us to exploit various areas in the contrast gain map. A huge-contrast gain in narrow zones can be achieved when both a dark fringe and a dark ring overlap on to an exoplanet. Compared to a single 8-m LBT aperture, the 23-m LBTI Fizeau imager can provide a gain in sensitivity (by a factor of 4), a gain in angular resolution (by a factor of 3) and, as well, a gain in raw contrast (by a factor of 2-1000 varying over the AO-corrected field of view).

  5. Mathematical impairment associated with high-contrast abnormalities in change detection and magnocellular visual evoked response.

    Science.gov (United States)

    Jastrzebski, Nicola R; Crewther, Sheila G; Crewther, David P

    2015-10-01

    The cause of developmental dyscalculia, a specific deficit in acquisition of arithmetic skills, particularly of enumeration, has never been investigated with respect to the patency of the visual magnocellular system. Here, the question of dysfunction of the afferent magnocellular cortical input and its dorsal stream projections was tested directly using nonlinear analysis of the visual evoked potential (VEP) and through the psychophysical ability to rapidly detect visual change. A group of young adults with self-reported deficiencies of arithmetical ability, showed marked impairment in magnitude estimation and enumeration performance-though not in lexical decision reaction times when compared with an arithmetically capable group controlled for age and handedness. Multifocal nonlinear VEPs were recorded at low (24 %) and high (96 %) contrast. First- and second-order VEP kernels were comparable between groups at low contrast, but not at high contrast. The mathematically impaired group showed an abnormal lack of contrast saturation in the shortest latency first-order peak (N60) and a delayed P100 positivity in the first slice of the second-order kernel. Both features have previously been argued to be physiological markers of magnocellular function. Mathematically impaired participants also performed worse on a gap paradigm change detection for digit task showing increased reaction times for high-contrast stimuli but not for low-contrast stimuli compared with controls. The VEP results give direct evidence of abnormality in the occipital processing of magnocellular information in those with mathematical impairment. The anomalous high visual contrast physiological and psychophysical performance suggests an abnormality in the inhibitory processes that normally result in saturation of contrast gain in the magnocellular system.

  6. Cost-effectiveness of iso- versus low-osmolality contrast media in outpatients with high risk of contrast medium-induced nephropathy.

    Science.gov (United States)

    Chicaíza-Becerra, Liliana Alejandra; García-Molina, Mario; Gamboa, Óscar

    2012-06-01

    Contrast media can cause acute renal failure by direct toxic effects on the tubular cells and kidney ischemia. Diabetics and hospitalized patients have a greater risk of developing contrast-induced nephropathy than the general population. The cost effectiveness of iso and low-osmolality contrast media was assessed in high risk outpatients. The analysis was based on a systematic literature review comparing the nephrotoxic effects of iso- to low-osmolality contrast media. Only direct costs were considered; these were obtained from the official tariff manual. Incremental cost-effectiveness ratios, efficiency curves and acceptability curves were calculated. Univariate sensitivity analyses were performed for costs and effects, as well as probabilistic analyses. Zero and 3% discounts were applied to results. The cost-effectiveness threshold was equal to the per capita GDP per life-year gained. Alternatives with Iopamidol and Iodixanol are preferable to the others, because both reduce risk of contrast-induced nephropathy and are less costly. The incremental cost-effectiveness of the Iodixanol alternative compared to the Iopamidol alternative is US$ 14,660 per additional life year gained; this is more than twice the threshold. The low-osmolality contrast medium, Iopamidol, appears to be cost-effective when compared with Iohexol or other low-osmolality contrast media (Iopromide, Iobitridol, Iomeprol, Iopentol and Ioxilan) in contrast-induced nephropathy, high-risk outpatients. The choice of the iso-osmolality contrast medium, Iodixanol, depends on its cost per vial and on the willingness to pay.

  7. Spatio-temporal patterns and environmental controls of small pelagic fish body condition from contrasted Mediterranean areas

    Science.gov (United States)

    Brosset, Pablo; Fromentin, Jean-Marc; Van Beveren, Elisabeth; Lloret, Josep; Marques, Virginie; Basilone, Gualtiero; Bonanno, Angelo; Carpi, Piera; Donato, Fortunata; Čikeš Keč, Vanja; De Felice, Andrea; Ferreri, Rosalia; Gašparević, Denis; Giráldez, Ana; Gücü, Ali; Iglesias, Magdalena; Leonori, Iole; Palomera, Isabel; Somarakis, Stylianos; Tičina, Vjekoslav; Torres, Pedro; Ventero, Ana; Zorica, Barbara; Ménard, Frédéric; Saraux, Claire

    2017-02-01

    Small pelagic fish are among the most ecologically and economically important marine fish species and are characterized by large fluctuations all over the world. In the Mediterranean Sea, low catches and biomass of anchovies and sardines have been described in some areas during the last decade, resulting in important fisheries crises. Therefore, we studied anchovy and sardine body condition variability, a key index of population health and its response to environmental and anthropogenic changes. Wide temporal and spatial patterns were investigated by analyzing separately data from scientific surveys and fisheries in eight Mediterranean areas between 1975 and 2015. Results showed that anchovy and sardine body condition as well as maximum size in some areas sharply decreased in most Mediterranean areas along years (except in the Northern Alboran Sea). Despite this general pattern, well-marked environmental differences between sub-regions were highlighted by several analyses and variations in body condition were not found to be homogeneous over all the Mediterranean Sea. Further, other analyses revealed that except for the Adriatic where major changes towards a lower body condition were concomitant with a decrease in river runoffs and chl-a concentration, no concomitant environmental regime shift was detected in other areas. Together, these analyses highlighted the current poor body condition of almost all small pelagic fish populations in the Mediterranean. Yet, global environmental indices could not explain the observed changes and the general decrease in condition might more likely come from regional environmental and/or anthropogenic (fishing) effects. A prolonged state of poor fish body condition, together with an observed reduced size and early age-at-maturity may have strong ecological, economic and social consequences all around the Mediterranean Sea.

  8. Control of energy spread and dark current in proton and ion beams generated in high-contrast laser solid interactions.

    Science.gov (United States)

    Dollar, F; Matsuoka, T; Petrov, G M; Thomas, A G R; Bulanov, S S; Chvykov, V; Davis, J; Kalinchenko, G; McGuffey, C; Willingale, L; Yanovsky, V; Maksimchuk, A; Krushelnick, K

    2011-08-05

    By using temporal pulse shaping of high-contrast, short pulse laser interactions with solid density targets at intensities of 2 × 10(21) W cm(-2) at a 45° incident angle, we show that it is possible to reproducibly generate quasimonoenergetic proton and ion energy spectra. The presence of a short pulse prepulse 33 ps prior to the main pulse produced proton spectra with an energy spread between 25% and 60% (ΔE/E) with energy of several MeV, with light ions becoming quasimonoenergetic for 50 nm targets. When the prepulse was removed, the energy spectra was broad. Numerical simulations suggest that expansion of the rear-side contaminant layer allowed for density conditions that prevented the protons from being screened from the sheath field, thus providing a low energy cutoff in the observed spectra normal to the target surface.

  9. Diffuse back-illumination setup for high temporally resolved extinction imaging

    DEFF Research Database (Denmark)

    Westlye, Fredrik Ree; Penney, Keith; Ivarsson, Anders

    2017-01-01

    in the optical system, enabling minimal exposure times and high-temporal resolution capabilities. The setup uses a customized engineered diffuser to transmit a constant radiance within a limited angular range such that radiant intensity is maximized while fulfilling the lighting criteria for optimal beam......This work presents the development of an optical setup for quantitative, high-temporal resolution line-of-sight extinction imaging in harsh optical environments. The application specifically targets measurements of automotive fuel sprays at high ambient temperature and pressure conditions where...... attenuation caused by refractive index gradients by an order of magnitude compared to previous high-temporal resolution setups....

  10. 3D-CT of the temporal bone area with high-speed processing

    Energy Technology Data Exchange (ETDEWEB)

    Hattori, Taku [Nagoya Univ. (Japan). Branch Hospital

    1994-12-01

    Three-dimentional (3D)-CT was introduced to represent abnormal findings in the temporal bone area utilizing a SOMATOM DRH CT scanner with accessory 3D reconstruction software and an exclusive high-speed 3D processing system, VOXEL FLINGER. In a patient with eosinophilic granuloma, a defect in the squamous part of the temporal bone was demonstrated suggesting exposure of the dura mater during surgery. In a patient with a normal ear, well-developed mastoid cavity, a part of the handle and the head of the malleus, the incudomalleal joint, the short limb, body and a part of the long limb of the incus and the round window niche were demonstrated. In a case of chronic otitis media, poorly developed mastoid cavity and a possible defect of the tip of the long limb of the incus were demonstrated, in contrast to the patient with the normal ear. 3D-CT yields objective and solid images which are useful for diagnosis, treatment planning and explanation of the pathology to patients and their family. To obtain convincing 3D images, physicians themselves have to choose exact rotation angles. It is not adequate to reconstruct original CT data using a CT computer with accessory 3D software whose processing capability is not good enough for this purpose. The conclusion is as follows: (1) it is necessary and effective to transfer original CT data into the memory of the exclusive high-speed 3D processing system and (2) process the data by the voxel memory method to establish a clinically valuable 3D-CT imaging system. (author).

  11. Temporal variation in earthworm abundance and diversity along hedgerow-to-field transects in contrasting agricultural land uses

    Science.gov (United States)

    Prendergast-Miller, Miranda T.; Jones, David; Hodson, Mark E.

    2017-04-01

    Earthworms are regarded as ecosystem engineers, integral to soil processes such as aggregation, nutrient cycling, water infiltration, plant growth and microbial function. Earthworm surveys were conducted for one year on hedge-to-field transects in arable and pasture fields (Yorkshire, UK). The transects incorporated hedgerow and field margin habitats and extended 60 m into the arable or pasture field. At defined distances, earthworm abundance and biomass were recorded, and earthworms were identified to species and ecological group. Soil density, moisture and temperature were also measured. Additional transects were surveyed on experimental plots with arable-to-ley conversions in the arable fields (wheat crop to grass-clover ley), and tilled plots in the pasture fields (grass-clover ley to wheat crop). The conversion plots were established to determine the benefit of grass-clover leys on soil function; and the tilled pasture plots were established to compare the impact of conventional or minimum tillage practices on earthworm abundance and diversity. A baseline survey was conducted before establishment of the experimental ley and tillage plots. The results showed differences in earthworm abundance, with greater earthworm numbers in the pasture soils compared to arable soils. In both soils, abundance of ecological group was endogeic > epigeic > anecic, and each group was dominated by the same species: Allolobophora chlorotica, Lumbricus castaneus and Apporectodea longa. After one year of treatment, there was some indication of increased earthworm abundance in the arable-to-ley conversion strips. Conversely, tillage in the pasture plots tended to reduce earthworm abundance, and conventional tillage tended to have the greater impact. However, within these major changes, there was also evidence of spatial (distance along transect; field location) and temporal (seasonal) variation on earthworm abundance. Although conversion to ley or tillage did not alter the pattern of

  12. Pupil dilation deconvolution reveals the dynamics of attention at high temporal resolution

    NARCIS (Netherlands)

    Wierda, Stefan M.; van Rijn, Hedderik; Taatgen, Niels A.; Martens, Sander

    2012-01-01

    The size of the human pupil increases as a function of mental effort. However, this response is slow, and therefore its use is thought to be limited to measurements of slow tasks or tasks in which meaningful events are temporally well separated. Here we show that high-temporal-resolution tracking of

  13. Temporal change of enhancement after gadolinium injection on contrast-enhanced CMR in reperfused acute myocardial infarction.

    Science.gov (United States)

    Matsumoto, Hidenari; Matsuda, Tetsuya; Miyamoto, Kenichi; Shimada, Toshihiko; Ushimaru, Shunpei; Mikuri, Mikiko; Yamazaki, Taketoshi

    2015-01-01

    A recent report demonstrated that early enhancement on contrast-enhanced cardiac magnetic resonance (CE-CMR) correlated with myocardial edema detected by T2-weighted CMR in reperfused acute myocardial infarction (AMI). However, the time at which the enhancement in salvaged myocardium disappears is yet to be determined. We aimed to examine the time course of the enhancement with the use of different quantification techniques and to compare the extent of enhancement with the myocardial edema. CE-CMR was performed at 2-20 min after gadolinium administration in 32 AMI patients. The extent of enhancement (% myocardium) was quantified by manual delineation and the threshold methods of 2-5 SDs above remote myocardium. In subendocardial infarct, the enhancement was greatest at 2 min regardless of the quantification techniques and decreased with time, particularly in the first 6 min. In transmural infarct, the change in the size of enhancement was modest although the time course of enhancement varied according to the quantification techniques. The sizes of enhancement were not significantly different between 15 and 20 min regardless of the techniques and infarct transmurality. The best agreement with myocardial edema was found at 2 min with average differences of 0.5% and -1.2% and limits of agreement of ±20.2% and ±21.2% for the manual and 2-SD techniques, respectively. The optimal timing for delineation of salvaged myocardium on CE-CMR is at 2min when the manual or 2-SD technique was employed. Imaging needs to be completed in a short time (ideally within a minute) because of rapid reduction of enhancement in salvaged myocardium. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  14. High-contrast en bloc staining of neuronal tissue for field emission scanning electron microscopy.

    Science.gov (United States)

    Tapia, Juan Carlos; Kasthuri, Narayanan; Hayworth, Kenneth J; Schalek, Richard; Lichtman, Jeff W; Smith, Stephen J; Buchanan, JoAnn

    2012-01-12

    Conventional heavy metal poststaining methods on thin sections lend contrast but often cause contamination. To avoid this problem, we tested several en bloc staining techniques to contrast tissue in serial sections mounted on solid substrates for examination by field emission scanning electron microscopy (FESEM). Because FESEM section imaging requires that specimens have higher contrast and greater electrical conductivity than transmission electron microscopy (TEM) samples, our technique uses osmium impregnation (OTO) to make the samples conductive while heavily staining membranes for segmentation studies. Combining this step with other classic heavy metal en bloc stains, including uranyl acetate (UA), lead aspartate, copper sulfate and lead citrate, produced clean, highly contrasted TEM and scanning electron microscopy (SEM) samples of insect, fish and mammalian nervous systems. This protocol takes 7-15 d to prepare resin-embedded tissue, cut sections and produce serial section images.

  15. High-Temporal-Resolution High-Spatial-Resolution Spaceborne SAR Based on Continuously Varying PRF.

    Science.gov (United States)

    Men, Zhirong; Wang, Pengbo; Li, Chunsheng; Chen, Jie; Liu, Wei; Fang, Yue

    2017-07-25

    Synthetic Aperture Radar (SAR) is a well-established and powerful imaging technique for acquiring high-spatial-resolution images of the Earth's surface. With the development of beam steering techniques, sliding spotlight and staring spotlight modes have been employed to support high-spatial-resolution applications. In addition to this strengthened high-spatial-resolution and wide-swath capability, high-temporal-resolution (short repeat-observation interval) represents a key capability for numerous applications. However, conventional SAR systems are limited in that the same patch can only be illuminated for several seconds within a single pass. This paper considers a novel high-squint-angle system intended to acquire high-spatial-resolution spaceborne SAR images with repeat-observation intervals varying from tens of seconds to several minutes within a single pass. However, an exponentially increased range cell migration would arise and lead to a conflict between the receive window and 'blind ranges'. An efficient data acquisition technique for high-temporal-resolution, high-spatial-resolution and high-squint-angle spaceborne SAR, in which the pulse repetition frequency (PRF) is continuously varied according to the changing slant range, is presented in this paper. This technique allows echo data to remain in the receive window instead of conflicting with the transmitted pulse or nadir echo. Considering the precision of hardware, a compromise and practical strategy is also proposed. Furthermore, a detailed performance analysis of range ambiguities is provided with respect to parameters of TerraSAR-X. For strong point-like targets, the range ambiguity of this technique would be better than that of uniform PRF technique. For this innovative technique, a resampling strategy and modified imaging algorithm have been developed to handle the non-uniformly sampled echo data. Simulations are performed to validate the efficiency of the proposed technique and the associated

  16. High-dose N-acetylcysteine for the prevention of contrast-induced nephropathy.

    Science.gov (United States)

    Trivedi, Hariprasad; Daram, Sumanth; Szabo, Aniko; Bartorelli, Antonio L; Marenzi, Giancarlo

    2009-09-01

    Whether N-acetylcysteine is beneficial for the prevention of contrast-induced nephropathy is uncertain. We conducted a meta-analysis to evaluate the efficacy of high-dose N-acetylcysteine for the prevention of contrast-induced nephropathy. Our prespecified inclusion criteria were as follows: adult subjects; English language literature; administration of high-dose N-acetylcysteine a priori defined as a daily dose greater than 1200 mg or a single periprocedural dose (within 4 hours of contrast exposure) greater than 600 mg; prospective trials of individuals randomized to N-acetylcysteine, administered orally or intravenously, versus a control group; and trials that included the end point of the incidence of contrast-induced nephropathy. Trials that compared N-acetylcysteine with another active treatment were excluded. Sixteen comparisons of patients randomized to high-dose N-acetylcysteine versus controls met our prespecified inclusion criteria with a total sample size of 1677 subjects (842 assigned to high-dose N-acetylcysteine and 835 assigned to the control arm). The average population age was 68 years, 38.7% were diabetic, and the majority was male (67.8% of reported instances). The weighted mean baseline creatinine of the overall population was 1.58 mg/dL. No significant heterogeneity was detected (P = .09; I(2) = 34%). The overall effect size assuming a common odds ratio revealed an odds ratio of 0.46 (95% confidence interval [CI], 0.33-0.63) for the occurrence of contrast-induced nephropathy with the use of high-dose N-acetylcysteine. The results of the more conservative random effects approach were similar (odds ratio = 0.52; 95% CI, 0.34-0.78). There was no evidence of publication bias (P = .34). Our results suggest that high-dose N-acetylcysteine decreases the incidence of contrast-induced nephropathy.

  17. Optical loss reduction in high-index-contrast chalcogenide glass waveguides via thermal reflow.

    Science.gov (United States)

    Hu, Juejun; Feng, Ning-Ning; Carlie, Nathan; Petit, Laeticia; Agarwal, Anu; Richardson, Kathleen; Kimerling, Lionel

    2010-01-18

    A thermal reflow technique is applied to high-index-contrast, sub-micron waveguides in As(2)S(3) chalcogenide glass to reduce the sidewall roughness and associated optical scattering loss. We show that the reflow process effectively decreases sidewall roughness of chalcogenide glass waveguides. A kinetic model is presented to quantitatively explain the sidewall roughness evolution during thermal reflow. Further, we develop a technique to calculate waveguide optical loss using the roughness evolution model, and predict the ultimate low loss limit in reflowed high-index-contrast glass waveguides. Up to 50% optical loss reduction after reflow treatment is experimentally observed, and the practical loss limiting factors are discussed.

  18. Performance Sensitivity Studies on the PIAA Implementation of the High-Contrast Imaging Testbed

    Science.gov (United States)

    Sidick, Erkin; Lou, John; Shaklan, Stuart; Levine, Marie

    2010-01-01

    This slide presentation reviews the sensitivity studies on the Phase-Induced Amplitude Apodization (PIAA), or pupil mapping using the High-Contrast Imaging Testbed (HCIT). PIAA is a promising technique in high-dynamic range stellar coronagraph. This presentation reports on the investigation of the effects of the phase and rigid-body errors of various optics on the narrowband contrast performance of the PIAA/HCIT hybrid system. The results have shown that the 2-step wavefront control method utilizing 2-DMs is quite effective in compensating the effects of realistic phase and rigid-body errors of various optics

  19. Monolithically integrated multi-wavelength VCSEL arrays using high-contrast gratings.

    Science.gov (United States)

    Karagodsky, Vadim; Pesala, Bala; Chase, Christopher; Hofmann, Werner; Koyama, Fumio; Chang-Hasnain, Connie J

    2010-01-18

    We propose a novel design for multi-wavelength arrays of vertical cavity surface-emitting lasers (VCSELs) using high-contrast gratings (HCGs) as top mirrors. A range of VCSEL cavity wavelengths in excess of 100 nm is predicted by modifying only the period and duty-cycle of the high-contrast gratings, while leaving the epitaxial layer thickness unchanged. VCSEL arrays fabricated with this novel design can easily accommodate the entire Er-doped fiber amplifier bandwidth with emission wavelengths defined solely by lithography with no restrictions in physical layout. Further, the entire process is identical to that of solitary VCSELs, facilitating cost-effective manufacturing.

  20. Contrasting Complement Control, Temporal Adjunct Control and Controlled Verbal Gerund Subjects in ASD: The Role of Contextual Cues in Reference Assignment

    OpenAIRE

    Janke, Vikki; Perovic, Alexandra

    2017-01-01

    This study examines two complex syntactic dependencies (complement control and sentence-final temporal adjunct control) and one pragmatic dependency (controlled verbal gerund subjects) in children with ASD. Sixteen high-functioning (HFA) children (aged 6 to 16) with a diagnosis of autism and no language impairment, matched on age, gender and non-verbal MA to one TD control group, and on age, gender and verbal MA to another TD control group, undertook three picture-selection tasks. Task 1 meas...

  1. Contrasting complement control, temporal adjunct control and controlled verbal gerund subjects in ASD: The role of contextual cues in reference assignment

    OpenAIRE

    Janke, V.; Perovic, A.

    2017-01-01

    This study examines two complex syntactic dependencies (complement control and sentence-final temporal adjunct control) and one pragmatic dependency (controlled verbal gerund subjects) in children with ASD. Sixteen high-functioning (HFA) children (aged 6–16) with a diagnosis of autism and no language impairment, matched on age, gender and non-verbal MA to one TD control group, and on age, gender and verbal MA to another TD control group, undertook three picture-selection tasks....

  2. Analysis of Spatio-Temporal Patterns of Leaf Area Index in Different Forest Types of India Using High Temporal Remote Sensing Data

    Science.gov (United States)

    Chhabra, A.; Panigrahy, S.

    2011-08-01

    Knowledge of temporal variations of Leaf Area Index (LAI) aids in understanding the climate-vegetation interaction of different vegetative systems. This information is amenable from high temporal remote sensing data. India has around 78.37 million hectare, accounting for 23.84% of the geographic area of the country under forest/tree cover. India has a diverse set of vegetation types ranging from tropical evergreen to dry deciduous. We present a detailed spatio-temporal and inter-seasonal analysis of LAI patterns in different forest types of India using MODIS 8-day composites global LAI/fPAR product for the year 2005 at 1-km spatial resolution. A forest cover mask was generated using SPOT 1-km landuse/landcover classification over the Indian region. The range of estimated LAI varied from 0.1-6.9 among the different forest types. Maximum LAI was observed in tropical evergreen forests in North-Eastern region and Western Ghats. Low LAI was observed in Central Indian region due to predominance of dry deciduous forests. The spatial patterns of seasonal variations detected that for most of the forest types, the peak LAI values were observed during September and October months of the autumn season in contrast to minimum LAI during summer season. The mean LAI and standard deviation for each 8-day LAI composite were also computed and mean monthly LAI profiles were derived for each forest type classified on the basis of their geographical locations. These results are useful indicators for detailed understanding of phenological sequence and may also serve as important inputs for deriving bioclimatic indices for different forest types of India.

  3. The growing population of dark objects that have high emissivity contrast

    Science.gov (United States)

    Sunshine, Jessica M.; Kelley, Michael S. P.; McAdam, Margaret M.

    2017-10-01

    At visible and near-infrared wavelengths dark asteroids, Trojan asteroids, and cometary nuclei are largely featureless and are thus characterized and compared primarily based on differences in their spectral slopes. In contrast, in the mid-infrared a series of telescopic observations (e.g., ISO, Spitzer, SOFIA) have revealed subtle but clear silicate emissions in the 9-11 µm region. For the most part, these features are very low in spectral contrast (~5%). However, Emery et al. (2006) showed that Spitzer spectra of Trojan asteroids can have much larger spectral contrast (~10-15%) akin to cometary comae and dust in planetary disks. Similar high-contrast silicate features were found by Kelley et al. (2017) in Spitzer spectra of bare cometary nuclei. Together these results suggest the presence of fine grained and likely highly porous surfaces (Emery et al., 2006; Vernazza et al., 2012). Here we report on archival spectroscopy with the Spitzer Space Telescope that shows two mainbelt asteroids 267 Tirza (D-type; 55 km diameter) and 1284 Lativa (T/L-type; 40 km diameter) also have strong 10 µm silicate emission features. Moreover, the shapes of their silicate features match those of the other Trojan D-types; the best agreement is with 1172 Aneas. If high porosity is responsible for the enhanced spectra contrast in these objects, that porosity must now be explained for objects over an extended range of heliocentric distances, sizes, and that likely have different accretionary and impact histories.

  4. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brun, E., E-mail: emmanuel.brun@esrf.fr [European Synchrotron Radiation Facility (ESRF), Grenoble 380000, France and Department of Physics, Ludwig-Maximilians University, Garching 85748 (Germany); Grandl, S.; Sztrókay-Gaul, A.; Gasilov, S. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Barbone, G. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Mittone, A.; Coan, P. [Department of Physics, Ludwig-Maximilians University, Garching 85748, Germany and Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Bravin, A. [European Synchrotron Radiation Facility (ESRF), Grenoble 380000 (France)

    2014-11-01

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  5. Highly magnetic iron carbide nanoparticles as effective T(2) contrast agents.

    Science.gov (United States)

    Huang, Guoming; Hu, Juan; Zhang, Hui; Zhou, Zijian; Chi, Xiaoqin; Gao, Jinhao

    2014-01-21

    This paper reports that iron carbide nanoparticles with high air-stability and strong saturation magnetization can serve as effective T2 contrast agents for magnetic resonance imaging. Fe5C2 nanoparticles (~20 nm in diameter) exhibit strong contrast enhancement with an r2 value of 283.2 mM(-1) S(-1), which is about twice as high as that of spherical Fe3O4 nanoparticles (~140.9 mM(-1) S(-1)). In vivo experiments demonstrate that Fe5C2 nanoparticles are able to produce much more significant MRI contrast enhancement than conventional Fe3O4 nanoparticles in living subjects, which holds great promise in biomedical applications.

  6. Low-signal, coronagraphic wavefront estimation with Kalman filtering in the high contrast imaging testbed

    Science.gov (United States)

    Riggs, A. J. Eldorado; Cady, Eric J.; Prada, Camilo M.; Kern, Brian D.; Zhou, Hanying; Kasdin, N. Jeremy; Groff, Tyler D.

    2016-07-01

    For direct imaging and spectral characterization of cold exoplanets in reflected light, the proposed Wide-Field Infrared Survey Telescope (WFIRST) Coronagraph Instrument (CGI) will carry two types of coronagraphs. The High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Laboratory has been testing both coronagraph types and demonstrated their abilities to achieve high contrast. Focal plane wavefront correction is used to estimate and mitigate aberrations. As the most time-consuming part of correction during a space mission, the acquisition of probed images for electric field estimation needs to be as short as possible. We present results from the HCIT of narrowband, low-signal wavefront estimation tests using a shaped pupil Lyot coronagraph (SPLC) designed for the WFIRST CGI. In the low-flux regime, the Kalman filter and iterated extended Kalman filter provide faster correction, better achievable contrast, and more accurate estimates than batch process estimation.

  7. Domain Decomposition Preconditioners for Multiscale Flows in High-Contrast Media

    KAUST Repository

    Galvis, Juan

    2010-01-01

    In this paper, we study domain decomposition preconditioners for multiscale flows in high-contrast media. We consider flow equations governed by elliptic equations in heterogeneous media with a large contrast in the coefficients. Our main goal is to develop domain decomposition preconditioners with the condition number that is independent of the contrast when there are variations within coarse regions. This is accomplished by designing coarse-scale spaces and interpolators that represent important features of the solution within each coarse region. The important features are characterized by the connectivities of high-conductivity regions. To detect these connectivities, we introduce an eigenvalue problem that automatically detects high-conductivity regions via a large gap in the spectrum. A main observation is that this eigenvalue problem has a few small, asymptotically vanishing eigenvalues. The number of these small eigenvalues is the same as the number of connected high-conductivity regions. The coarse spaces are constructed such that they span eigenfunctions corresponding to these small eigenvalues. These spaces are used within two-level additive Schwarz preconditioners as well as overlapping methods for the Schur complement to design preconditioners. We show that the condition number of the preconditioned systems is independent of the contrast. More detailed studies are performed for the case when the high-conductivity region is connected within coarse block neighborhoods. Our numerical experiments confirm the theoretical results presented in this paper. © 2010 Society for Industrial and Applied Mathematics.

  8. Whole-Body High-Pitch CT Angiography: Strategies to Reduce Radiation Dose and Contrast Volume.

    Science.gov (United States)

    Manneck, Sebastian; Hurwitz, Lynne M; Seaman, Danielle M; Heye, Tobias; Boll, Daniel T

    2017-10-05

    The purpose of this study was to assess the noninferiority of dual-source high-pitch CT angiography (CTA) performed with high-concentration (iopamidol 370) low-volume (60 mL) iodinated contrast material at low voltage (100 kVp) in comparison with dual-source high-pitch CTA with standard-of-care low-concentration (iopamidol 300) standard-volume (75 mL) iodinated contrast material at high voltage (120 kVp) to determine whether use of the high-concentration low-volume method would afford a reduction in radiation dose and contrast volume without negatively affecting vascular opacification. This study had three arms. A phantom was used to assess vascular contrast enhancement at different iodine and saline solution dilutions with iopamidol 300 or 370 to compare lower-iodination (iopamidol 300) high-voltage (120 kVp) high-pitch (120 kVp, 250 mAs) imaging with higher-iodination (iopamidol 370) low-voltage (100 kVp) high-pitch (100 kVp, 100-240 mAs) acquisition. Metal-oxide-semiconductor field-effect transistors were placed in an anthropomorphic phantom to extract organ-based radiation profiles, and ANOVA was performed. The study prospectively enrolled 150 patients: 50 patients received 75 mL iopamidol 300, and image acquisition was performed at 120 kVp and 250 mAs; 50 patients received 75 mL iopamidol 370, and acquisition was performed at 100 kVp and 240 mAs; and 50 patients received 60 mL iopamidol, and acquisition was performed at 370 at 100 kVp and 240 mAs. Vascular signal-to-noise ratio was evaluated at 18 anatomic locations. Longitudinal signal-to-noise ratio was used to assess homogeneity of contrast enhancement. Size-specific dose estimates were calculated. Statistical analyses were performed by ANOVA. Noninferiority of high-concentration (iopamidol 370) low-voltage (100 kVp) high-pitch acquisitions compared with low-concentration (iopamidol 300) high-voltage (120 kVp) high-pitch acquisition was achieved at 170 mAs in vitro. Radiation assessment showed significant

  9. Efficient quality-eactor estimation of a vertical cavity employing a high-contrast grating

    DEFF Research Database (Denmark)

    Taghizadeh, Alireza; Mørk, Jesper; Chung, Il-Sug

    2017-01-01

    Hybrid vertical cavity lasers employing high-contrast grating reflectors are attractive for Si-integrated light source applications. Here, a method for reducing a three-dimensional (3D) optical simulation of this laser structure to lower-dimensional simulations is suggested, which allows for very...

  10. Experiencing More Mathematics Anxiety than Expected? Contrasting Trait and State Anxiety in High Achieving Students

    Science.gov (United States)

    Roos, A.-L.; Bieg, M.; Goetz, T.; Frenzel, A. C.; Taxer, J.; Zeidner, M.

    2015-01-01

    This study examined mathematics anxiety among high and low achieving students (N = 237, grades 9 and 10) by contrasting trait (habitual) and state (momentary) assessments of anxiety. Previous studies have found that trait anxiety measures are typically rated higher than state measures. Furthermore, the academic self-concept has been identified to…

  11. Dynamical dispersion engineering in coupled vertical cavities employing a high-contrast grating

    DEFF Research Database (Denmark)

    Taghizadeh, Alireza; Chung, Il-Sug

    2017-01-01

    strength. This can be implemented by employing a high-contrast grating (HCG) as the coupling reflector in a system of two coupled vertical cavities, and engineering both the HCG reflection phase and amplitude response. Several examples of HCG-based coupled cavities with novel features are discussed...

  12. High-energy x-ray grating-based phase-contrast radiography of human anatomy

    Science.gov (United States)

    Horn, Florian; Hauke, Christian; Lachner, Sebastian; Ludwig, Veronika; Pelzer, Georg; Rieger, Jens; Schuster, Max; Seifert, Maria; Wandner, Johannes; Wolf, Andreas; Michel, Thilo; Anton, Gisela

    2016-03-01

    X-ray grating-based phase-contrast Talbot-Lau interferometry is a promising imaging technology that has the potential to raise soft tissue contrast in comparison to conventional attenuation-based imaging. Additionally, it is sensitive to attenuation, refraction and scattering of the radiation and thus provides complementary and otherwise inaccessible information due to the dark-field image, which shows the sub-pixel size granularity of the measured object. Until recent progress the method has been mainly limited to photon energies below 40 keV. Scaling the method to photon energies that are sufficient to pass large and spacious objects represents a challenging task. This is caused by increasing demands regarding the fabrication process of the gratings and the broad spectra that come along with the use of polychromatic X-ray sources operated at high acceleration voltages. We designed a setup that is capable to reach high visibilities in the range from 50 to 120 kV. Therefore, spacious and dense parts of the human body with high attenuation can be measured, such as a human knee. The authors will show investigations on the resulting attenuation, differential phase-contrast and dark-field images. The images experimentally show that X-ray grating-based phase-contrast radiography is feasible with highly absorbing parts of the human body containing massive bones.

  13. Modeling the Subjective Quality of Highly Contrasted Videos Displayed on LCD With Local Backlight Dimming

    DEFF Research Database (Denmark)

    Mantel, Claire; Bech, Søren; Korhonen, Jari

    2015-01-01

    signal can then be used as input to objective quality metrics. The focus of this paper is on determining which characteristics of locally backlit displays influence quality assessment. A subjective experiment assessing the quality of highly contrasted videos displayed with various local backlight...

  14. Broadband MEMS-tunable high-index-contrast subwavelength grating long-wavelength VCSEL

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Iakovlev, Vladimir; Sirbu, Alexei

    2010-01-01

    A widely-tunable single-mode 1.3 μm vertical-cavity surface-emitting laser structure incorporating a microelectromechanical system-tunable high-index-contrast subwavelength grating (HCG) mirror is suggested and numerically investigated. A linear tuning range of 100 nm and a wavelength tuning effi...

  15. VCSELs with a high-index-contrast grating for mode-division multiplexing

    DEFF Research Database (Denmark)

    Ran, Qijiang; Mørk, Jesper

    2013-01-01

    A novel vertical-cavity surface-emitting laser (VCSEL) structure for space division multiplexing (SDM) is proposed and numerically investigated. This laser structure employs a high-index-contrast grating (HCG) as a light-emitting mirror. The reflectivity of the HCG mirror is spatially modulated......-integrated VCSEL approach can be a much more compact and cheaper alternative....

  16. A high resolution temporal study of phytoplankton bloom dynamics in the eutrophic Taw Estuary (SW England).

    Science.gov (United States)

    Maier, Gerald; Glegg, Gillian A; Tappin, Alan D; Worsfold, Paul J

    2012-09-15

    The Taw Estuary (SW England) is eutrophic as a result of enhanced nutrient inputs from its catchment. However, factors influencing the timing and extent of phytoplankton bloom formation are not fully understood in this system. In this study, high resolution chemical and biological sampling was undertaken in late-winter/spring and summer 2008 in order to gain further insights into bloom dynamics in the Taw Estuary. Temporal variations in chlorophyll a maxima in the upper and middle estuary during summer were controlled by river flow and tidal amplitude, with nutrient limitation probably less important. Concentrations of chlorophyll a were highest during low river flow and neap tides. Increased river flows advected the chlorophyll maximum to the outer estuary, and under highest river discharges, chlorophyll a concentrations were further reduced. This feature was even more pronounced when spring tides coincided with high flows. The main bloom species were the diatoms Asterionellopsis glacialis and Thalassiosira guillardii. Using two multivariate statistical techniques in combination, five distinct physical and biogeochemical states in the Taw estuarine waters were identified. These states can be summarised as: A(1), high chlorophyll a, high temperature, long residence times, nutrient depletion; A(2), strong coastal water influence; B(1), decreasing chlorophyll a, increasing river flow and/or spring tides; B(2), transitional between states A(1) and B(3); B(3), high river flow. It was thus possible to differentiate between contrasting environmental conditions that were either beneficial or detrimental for the development of algal blooms. A conceptual model of diatom - dominated primary production for the Taw Estuary is proposed which describes how physical controls (river flow, tidal state) moderate plankton biomass production in the upper and mid - estuarine regions. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Rational design, synthesis, and characterization of highly fluorescent optical switches for high-contrast optical lock-in detection (OLID) imaging microscopy in living cells.

    Science.gov (United States)

    Petchprayoon, Chutima; Yan, Yuling; Mao, Shu; Marriott, Gerard

    2011-02-01

    A major challenge in cell biology is to elucidate molecular mechanisms that underlie the spatio-temporal control of cellular processes. These studies require microscope imaging techniques and associated optical probes that provide high-contrast and high-resolution images of specific proteins and their complexes. Auto-fluorescence however, can severely compromise image contrast and represents a fundamental limitation for imaging proteins within living cells. We have previously shown that optical switch probes and optical lock-in detection (OLID) image microscopy improve image contrast in high background environments. Here, we present the design, synthesis, and characterization of amino-reactive and cell permeable optical switches that integrate the highly fluorescent fluorophore, tetramethylrhodamine (TMR) and spironaphthoxazine (NISO), a highly efficient optical switch. The NISO moiety in TMR-NISO undergoes rapid and reversible, excited-state driven transitions between a colorless spiro (SP)-state and a colored merocyanine (MC)-state in response to irradiation with 365 and >530nm light. In the MC-state, the TMR (donor) emission is almost completely extinguished by Förster resonance energy transfer (FRET) to the MC probe (acceptor), whereas in the colorless SP-state, the quantum yield for TMR fluorescence is maximal. Irradiation of TMR-NISO with a defined sequence of 365 and 546nm manipulates the levels of SP and MC with concomitant modulation of FRET efficiency and the TMR fluorescence signal. High fidelity optical switching of TMR fluorescence is shown for TMR-NISO probes in vitro and for membrane permeable TMR-NISO within living cells. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Optical phased array using high-contrast grating all-pass filters for fast beam steering

    Science.gov (United States)

    Yang, Weijian; Sun, Tianbo; Rao, Yi; Chan, Trevor; Megens, Mischa; Yoo, Byung-Wook; Horsley, David A.; Wu, Ming C.; Chang-Hasnain, Connie J.

    2013-03-01

    A novel 8x8 optical phased array based on high-contrast grating (HCG) all-pass filters (APFs) is experimentally demonstrated with high speed beam steering. Highly efficient phase tuning is achieved by micro-electro-mechanical actuation of the HCG to tune the cavity length of the APFs. Using APF phase-shifters allows a large phase shift with an actuation range of only tens of nanometers. The ultrathin HCG further ensures a high tuning speed (0.626 MHz). Both one-dimensional and two-dimensional HCGs are demonstrated as the actuation mirrors of the APF arrays with high beam steering performance.

  19. CHIPS: The Carina High-contrast Imaging Project of massive Stars

    Science.gov (United States)

    Rainot, Alan; Sana, Hugues; Gomez-Gonzalez, Carlos A.; Absil, Olivier; Delorme, Philippe; Almeida, Leonardo; Caballero-Nieves, Saida; Kratter, Kaitlin; Lacour, Sylvestre; Le Bouquin, Jean-Baptiste; Pueyo, Laurent; Zinnecker, Hans

    2017-11-01

    The formation of massive stars remains one of the most intriguing questions in astrophysics today. The main limitations result from the difficulty to obtain direct observational constraints on the formation process itself. In this context, the Carina High-contrast Imaging Project of massive Stars (CHIPS) aims to observe all 80+ O stars in the Carina nebula using the new VLT 2nd-generation extreme-AO instrument SPHERE. This instrument offers unprecedented imaging contrast allowing us to detect the faintest companions around massive stars. These novel observational constraints will help to discriminate between the different formation scenarios by comparing their predictions for companion statistics and properties.

  20. A low-threshold high-index-contrast grating (HCG)-based organic VCSEL

    Science.gov (United States)

    Shayesteh, Mohammad Reza; Darvish, Ghafar; Ahmadi, Vahid

    2015-12-01

    We propose a low-threshold high-index-contrast grating (HCG)-based organic vertical-cavity surface-emitting laser (OVCSEL). The device has the feasibility to apply both electrical and optical excitation. The microcavity of the laser is a hybrid photonic crystal (HPC) in which the top distributed Bragg reflector (DBR) is replaced by a sub-wavelength high-contrast-grating layer, and provides a high-quality factor. The simulated quality factor of the microcavity is shown to be as high as 282,000. We also investigate the threshold behavior and the dynamics of the OVCSEL optically pumped with sub-picosecond pulses. Results from numerical simulation show that lasing threshold is 75 nJ/cm2.

  1. High-index-contrast grating reflector with beam steering ability for the transmitted beam

    DEFF Research Database (Denmark)

    Carletti, Luca; Malureanu, Radu; Mørk, Jesper

    2011-01-01

    High-index contrast grating mirrors providing wave front control of the transmitted light as well as high reflectivity over a broad bandwidth are suggested and both numerically and experimentally investigated. General design rules to engineer these structures for different applications are derive....... Such grating mirrors would have a significant impact on low cost laser fabrication, since a more efficient integration of optoelectronic modules can be achieved by avoiding expensive external lens systems.......High-index contrast grating mirrors providing wave front control of the transmitted light as well as high reflectivity over a broad bandwidth are suggested and both numerically and experimentally investigated. General design rules to engineer these structures for different applications are derived...

  2. Achieving High Contrast for Exoplanet Imaging with a Kalman Filter and Stroke Minimization

    Science.gov (United States)

    Eldorado Riggs, A. J.; Groff, T. D.; Kasdin, N. J.; Carlotti, A.; Vanderbei, R. J.

    2014-01-01

    High contrast imaging requires focal plane wavefront control and estimation to correct aberrations in an optical system; non-common path errors prevent the use of conventional estimation with a separate wavefront sensor. The High Contrast Imaging Laboratory (HCIL) at Princeton has led the development of several techniques for focal plane wavefront control and estimation. In recent years, we developed a Kalman filter for optimal wavefront estimation. Our Kalman filter algorithm is an improvement upon DM Diversity, which requires at least two images pairs each iteration and does not utilize any prior knowledge of the system. The Kalman filter is a recursive estimator, meaning that it uses the data from prior estimates along with as few as one new image pairs per iteration to update the electric field estimate. Stroke minimization has proven to be a feasible controller for achieving high contrast. While similar to a variation of Electric Field Conjugation (EFC), stroke minimization achieves the same contrast with less stroke on the DMs. We recently utilized these algorithms to achieve high contrast for the first time in our experiment at the High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Laboratory (JPL). Our HCIT experiment was also the first demonstration of symmetric dark hole correction in the image plane using two DMs--this is a major milestone for future space missions. Our ongoing work includes upgrading our optimal estimator to include an estimate of the incoherent light in the system, which allows for simultaneous estimation of the light from a planet along with starlight. The two-DM experiment at the HCIT utilized a shaped pupil coronagraph. Those tests utilized ripple style, free-standing masks etched out of silicon, but our current work is in designing 2-D optimized reflective shaped pupils. In particular, we have created several designs for the AFTA telescope, whose pupil presents major hurdles because of its atypical pupil obstructions. Our

  3. A high-power fiber-coupled semiconductor light source with low spatio-temporal coherence

    Science.gov (United States)

    Schittko, Robert; Mazurenko, Anton; Tai, M. Eric; Lukin, Alexander; Rispoli, Matthew; Menke, Tim; Kaufman, Adam M.; Greiner, Markus

    2017-04-01

    Interference-induced distortions pose a significant challenge to a variety of experimental techniques, ranging from full-field imaging applications in biological research to the creation of optical potentials in quantum gas microscopy. Here, we present a design of a high-power, fiber-coupled semiconductor light source with low spatio-temporal coherence that bears the potential to reduce the impact of such distortions. The device is based on an array of non-lasing semiconductor emitters mounted on a single chip whose optical output is coupled into a multi-mode fiber. By populating a large number of fiber modes, the low spatial coherence of the input light is further reduced due to the differing optical path lengths amongst the modes and the short coherence length of the light. In addition to theoretical calculations showcasing the feasibility of this approach, we present experimental measurements verifying the low degree of spatial coherence achievable with such a source, including a detailed analysis of the speckle contrast at the fiber end. We acknowledge support from the National Science Foundation, the Gordon and Betty Moore Foundation's EPiQS Initiative, an Air Force Office of Scientific Research MURI program and an Army Research Office MURI program.

  4. High-Contrast Imaging using Adaptive Optics for Extrasolar Planet Detection

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Julia Wilhelmsen [Univ. of California, Davis, CA (United States)

    2006-01-01

    Direct imaging of extrasolar planets is an important, but challenging, next step in planetary science. Most planets identified to date have been detected indirectly--not by emitted or reflected light but through the effect of the planet on the parent star. For example, radial velocity techniques measure the doppler shift in the spectrum of the star produced by the presence of a planet. Indirect techniques only probe about 15% of the orbital parameter space of our solar system. Direct methods would probe new parameter space, and the detected light can be analyzed spectroscopically, providing new information about detected planets. High contrast adaptive optics systems, also known as Extreme Adaptive Optics (ExAO), will require contrasts of between 10-6 and 10-7 at angles of 4-24 λ/D on an 8-m class telescope to image young Jupiter-like planets still warm with the heat of formation. Contrast is defined as the intensity ratio of the dark wings of the image, where a planet might be, to the bright core of the star. Such instruments will be technically challenging, requiring high order adaptive optics with > 2000 actuators and improved diffraction suppression. Contrast is ultimately limited by residual static wavefront errors, so an extrasolar planet imager will require wavefront control with an accuracy of better than 1 nm rms within the low- to mid-spatial frequency range. Laboratory demonstrations are critical to instrument development. The ExAO testbed at the Laboratory for Adaptive Optics was designed with low wavefront error and precision optical metrology, which is used to explore contrast limits and develop the technology needed for an extrasolar planet imager. A state-of-the-art, 1024-actuator micro-electrical-mechanical-systems (MEMS) deformable mirror was installed and characterized to provide active wavefront control and test this novel technology. I present 6.5 x 10-8 contrast measurements with a prolate shaped pupil and

  5. Temporal optimization of ultrabroadband high-energy OPCPA

    National Research Council Canada - National Science Library

    Jeffrey Moses; Cristian Manzoni; Shu-Wei Huang; Giulio Cerullo; Franz X. Kaertner

    2009-01-01

    We present general guidelines for the design of ultrabroadband, high-energy optical parametric chirped-pulse amplifiers, where maximization of both conversion efficiency and bandwidth and simultaneous...

  6. Improved contrast for high frame rate imaging using coherent compounding combined with spatial matched filtering.

    Science.gov (United States)

    Lou, Yang; Yen, Jesse T

    2017-07-01

    The concept of high frame rate ultrasound imaging (typically greater than 1000 frames per second) has inspired new fields of clinical applications for ultrasound imaging such as fast cardiovascular imaging, fast Doppler imaging and real-time 3D imaging. Coherent plane-wave compounding is a promising beamforming technique to achieve high frame rate imaging. By combining echoes from plane waves with different angles, dynamic transmit focusing is efficiently accomplished at all points in the image field. Meanwhile, the image frame rate can still be kept at a high level. Spatial matched filtering (SMF) with plane-wave insonification is a novel ultrafast beamforming method. An analytical study shows that SMF is equivalent to synthetic aperture methods that can provide dynamic transmit-receive focusing throughout the field of view. Experimental results show that plane-wave SMF has better performance than dynamic-receive focusing. In this paper, we propose integrating coherent plane-wave compounding with SMF to obtain greater image contrast. By using a combination of SMF beamformed images, image contrast is improved without degrading its high frame rate capabilities. The performance of compounded SMF (CSMF) is evaluated and compared with that of synthetic aperture focusing technique (SAFT) beamforming and compounded dynamic-receive-focus (CDRF) beamforming. The image quality of different beamforming methods was quantified in terms of contrast-to-noise ratio (CNR). Our results show that the new SMF based plane-wave compounding method provides better contrast than DAS based compounding method. Also CSMF can obtain a similar contrast level to dynamic transmit-receive focusing with only 21 transmit events. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Mode decomposition methods for flows in high-contrast porous media. A global approach

    KAUST Repository

    Ghommem, Mehdi

    2014-01-01

    We apply dynamic mode decomposition (DMD) and proper orthogonal decomposition (POD) methods to flows in highly-heterogeneous porous media to extract the dominant coherent structures and derive reduced-order models via Galerkin projection. Permeability fields with high contrast are considered to investigate the capability of these techniques to capture the main flow features and forecast the flow evolution within a certain accuracy. A DMD-based approach shows a better predictive capability due to its ability to accurately extract the information relevant to long-time dynamics, in particular, the slowly-decaying eigenmodes corresponding to largest eigenvalues. Our study enables a better understanding of the strengths and weaknesses of the applicability of these techniques for flows in high-contrast porous media. Furthermore, we discuss the robustness of DMD- and POD-based reduced-order models with respect to variations in initial conditions, permeability fields, and forcing terms. © 2013 Elsevier Inc.

  8. Fundamental limitations of high contrast imaging set by small sample statistics

    Energy Technology Data Exchange (ETDEWEB)

    Mawet, D.; Milli, J.; Wahhaj, Z. [European Southern Observatory, Alonso de Cordóva 3107, Vitacura, Santiago (Chile); Pelat, D. [LUTH, Observatoire de Paris, CNRS, UPMC and University Paris Diderot, 5 place Jules Janssen, F-92195 Meudon (France); Absil, O.; Delacroix, C. [Département d' Astrophysique, Géophysique et Océanographie, Université de Liège, 17 Allée du Six Août, B-4000 Liège (Belgium); Boccaletti, A. [LESIA, Observatoire de Paris, CNRS, UPMC and University Paris Diderot, 5 place Jules Janssen, F-92195 Meudon (France); Kasper, M. [European Southern Observatory Headquarters, Karl-Schwarzschild-Strasse 2, D-85748 Garching bei München (Germany); Kenworthy, M. [Leiden Observatory, Leiden University, P.O. Box 9513, 2300-RA Leiden (Netherlands); Marois, C. [NRC, Herzberg Institute of Astrophysics, Victoria, BC V9E 2E7 (Canada); Mennesson, B. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Pueyo, L. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States)

    2014-09-10

    In this paper, we review the impact of small sample statistics on detection thresholds and corresponding confidence levels (CLs) in high-contrast imaging at small angles. When looking close to the star, the number of resolution elements decreases rapidly toward small angles. This reduction of the number of degrees of freedom dramatically affects CLs and false alarm probabilities. Naively using the same ideal hypothesis and methods as for larger separations, which are well understood and commonly assume Gaussian noise, can yield up to one order of magnitude error in contrast estimations at fixed CL. The statistical penalty exponentially increases toward very small inner working angles. Even at 5-10 resolution elements from the star, false alarm probabilities can be significantly higher than expected. Here we present a rigorous statistical analysis that ensures robustness of the CL, but also imposes a substantial limitation on corresponding achievable detection limits (thus contrast) at small angles. This unavoidable fundamental statistical effect has a significant impact on current coronagraphic and future high-contrast imagers. Finally, the paper concludes with practical recommendations to account for small number statistics when computing the sensitivity to companions at small angles and when exploiting the results of direct imaging planet surveys.

  9. Novel Gd nanoparticles enhance vascular contrast for high-resolution magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Tot Bui

    2010-09-01

    Full Text Available Gadolinium (Gd, with its 7 unpaired electrons in 4f orbitals that provide a very large magnetic moment, is proven to be among the best agents for contrast enhanced MRI. Unfortunately, the most potent MR contrast agent based on Gd requires relatively high doses of Gd. The Gd-chelated to diethylene-triamine-penta-acetic acid (DTPA, or other derivatives (at 0.1 mmole/kg recommended dose, distribute broadly into tissues and clear through the kidney. These contrast agents carry the risk of Nephrogenic Systemic Fibrosis (NSF, particularly in kidney impaired subjects. Thus, Gd contrast agents that produce higher resolution images using a much lower Gd dose could address both imaging sensitivity and Gd safety.To determine whether a biocompatible lipid nanoparticle with surface bound Gd can improve MRI contrast sensitivity, we constructed Gd-lipid nanoparticles (Gd-LNP containing lipid bound DTPA and Gd. The Gd-LNP were intravenously administered to rats and MR images collected. We found that Gd in Gd-LNP produced a greater than 33-fold higher longitudinal (T(1 relaxivity, r(1, constant than the current FDA approved Gd-chelated contrast agents. Intravenous administration of these Gd-LNP at only 3% of the recommended clinical Gd dose produced MRI signal-to-noise ratios of greater than 300 in all vasculatures. Unlike current Gd contrast agents, these Gd-LNP stably retained Gd in normal vasculature, and are eliminated predominately through the biliary, instead of the renal system. Gd-LNP did not appear to accumulate in the liver or kidney, and was eliminated completely within 24 hrs.The novel Gd-nanoparticles provide high quality contrast enhanced vascular MRI at 97% reduced dose of Gd and do not rely on renal clearance. This new agent is likely to be suitable for patients exhibiting varying degrees of renal impairment. The simple and adaptive nanoparticle design could accommodate ligand or receptor coating for drug delivery optimization and in vivo drug

  10. Characterization of a high-energy in-line phase contrast tomosynthesis prototype.

    Science.gov (United States)

    Wu, Di; Yan, Aimin; Li, Yuhua; Wong, Molly D; Zheng, Bin; Wu, Xizeng; Liu, Hong

    2015-05-01

    In this research, a high-energy in-line phase contrast tomosynthesis prototype was developed and characterized through quantitative investigations and phantom studies. The prototype system consists of an x-ray source, a motorized rotation stage, and a CMOS detector with a pixel pitch of 0.05 mm. The x-ray source was operated at 120 kVp for this study, and the objects were mounted on the rotation stage 76.2 cm (R1) from the source and 114.3 cm (R2) from the detector. The large air gap between the object and detector guarantees sufficient phase-shift effects. The quantitative evaluation of this prototype included modulation transfer function and noise power spectrum measurements conducted under both projection mode and tomosynthesis mode. Phantom studies were performed including three custom designed phantoms with complex structures: a five-layer bubble wrap phantom, a fishbone phantom, and a chicken breast phantom with embedded fibrils and mass structures extracted from an ACR phantom. In-plane images of the phantoms were acquired to investigate their image qualities through observation, intensity profile plots, edge enhancement evaluations, and/or contrast-to-noise ratio calculations. In addition, the robust phase-attenuation duality (PAD)-based phase retrieval method was applied to tomosynthesis for the first time in this research. It was utilized as a preprocessing method to fully exhibit phase contrast on the angular projection before reconstruction. The resolution and noise characteristics of this high-energy in-line phase contrast tomosynthesis prototype were successfully investigated and demonstrated. The phantom studies demonstrated that this imaging prototype can successfully remove the structure overlapping in phantom projections, obtain delineate interfaces, and achieve better contrast-to-noise ratio after applying phase retrieval to the angular projections. This research successfully demonstrated a high-energy in-line phase contrast tomosynthesis

  11. Automated land cover change detection: the quest for meaningful high temporal time series extraction

    CSIR Research Space (South Africa)

    Salmon, BP

    2010-07-01

    Full Text Available detection, clustering, satellite, time series. 1. INTRODUCTION The transformation of natural vegetation by practices such as deforestation, agricultural expansion and urbanization, has significant impacts on hydrology, ecosystems and climate [1...]. Coarse resolution satellite data provide the only regional, spa- tial, long-term and high temporal measurements for monitor- ing the earth’s surface. Automated land cover change detec- tion at regional or global scales, using hyper-temporal, coarse...

  12. Specular Reflectivity and Hot-Electron Generation in High-Contrast Relativistic Laser-Plasma Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, Gregory Elijah [The Ohio State Univ., Columbus, OH (United States)

    2013-01-01

    Ultra-intense laser (> 1018 W/cm2) interactions with matter are capable of producing relativistic electrons which have a variety of applications in state-of-the-art scientific and medical research conducted at universities and national laboratories across the world. Control of various aspects of these hot-electron distributions is highly desired to optimize a particular outcome. Hot-electron generation in low-contrast interactions, where significant amounts of under-dense pre-plasma are present, can be plagued by highly non-linear relativistic laser-plasma instabilities and quasi-static magnetic field generation, often resulting in less than desirable and predictable electron source characteristics. High-contrast interactions offer more controlled interactions but often at the cost of overall lower coupling and increased sensitivity to initial target conditions. An experiment studying the differences in hot-electron generation between high and low-contrast pulse interactions with solid density targets was performed on the Titan laser platform at the Jupiter Laser Facility at Lawrence Livermore National Laboratory in Livermore, CA. To date, these hot-electrons generated in the laboratory are not directly observable at the source of the interaction. Instead, indirect studies are performed using state-of-the-art simulations, constrained by the various experimental measurements. These measurements, more-often-than-not, rely on secondary processes generated by the transport of these electrons through the solid density materials which can susceptible to a variety instabilities and target material/geometry effects. Although often neglected in these types of studies, the specularly reflected light can provide invaluable insight as it is directly influenced by the interaction. In this thesis, I address the use of (personally obtained) experimental specular reflectivity measurements to indirectly study hot-electron generation in the context of high-contrast, relativistic

  13. High contrast ballistic imaging using femtosecond optical Kerr gate of tellurite glass.

    Science.gov (United States)

    Tan, Wenjiang; Zhou, Zhiguang; Lin, Aoxiang; Si, Jinhai; Zhan, Pingping; Wu, Bin; Hou, Xun

    2013-03-25

    We investigated the ballistic imaging technique using femtosecond optical Kerr gate of a tellurite glass. High contrast images of an object hidden behind turbid media were obtained. Compared to the conventional femtosecond optical Kerr gate using fused quartz, the optical Kerr gate using tellurite glass has more capacity to acquire high quality images of the object hidden behind a high optical density turbid medium. The experimental results indicated that the tellurite glass is a good candidate as the optical Kerr material for the ballistic imaging technique due to its large optical nonlinearity.

  14. High-resolution breast tomography at high energy: a feasibility study of phase contrast imaging on a whole breast

    Science.gov (United States)

    Sztrókay, A.; Diemoz, P. C.; Schlossbauer, T.; Brun, E.; Bamberg, F.; Mayr, D.; Reiser, M. F.; Bravin, A.; Coan, P.

    2012-05-01

    Previous studies on phase contrast imaging (PCI) mammography have demonstrated an enhancement of breast morphology and cancerous tissue visualization compared to conventional imaging. We show here the first results of the PCI analyser-based imaging (ABI) in computed tomography (CT) mode on whole and large (>12 cm) tumour-bearing breast tissues. We demonstrate in this work the capability of the technique of working at high x-ray energies and producing high-contrast images of large and complex specimens. One entire breast of an 80-year-old woman with invasive ductal cancer was imaged using ABI-CT with monochromatic 70 keV x-rays and an area detector of 92×92 µm2 pixel size. Sagittal slices were reconstructed from the acquired data, and compared to corresponding histological sections. Comparison with conventional absorption-based CT was also performed. Five blinded radiologists quantitatively evaluated the visual aspects of the ABI-CT images with respect to sharpness, soft tissue contrast, tissue boundaries and the discrimination of different structures/tissues. ABI-CT excellently depicted the entire 3D architecture of the breast volume by providing high-resolution and high-contrast images of the normal and cancerous breast tissues. These results are an important step in the evolution of PCI-CT towards its clinical implementation.

  15. Photoacoustic contrast imaging of biological tissues with nanodiamonds fabricated for high near-infrared absorbance.

    Science.gov (United States)

    Zhang, Ti; Cui, Huizhong; Fang, Chia-Yi; Su, Long-Jyun; Ren, Shenqiang; Chang, Huan-Cheng; Yang, Xinmai; Forrest, M Laird

    2013-02-01

    Radiation-damaged nanodiamonds (DNDs) are potentially ideal optical contrast agents for photoacoustic (PA) imaging in biological tissues due to their low toxicity and high optical absorbance. PA imaging contrast agents have been limited to quantum dots and gold particles, since most existing carbon-based nanoparticles, including fluorescent nanodiamonds, do not have sufficient optical absorption in the near-infrared (NIR) range. A new DND by He+ ion beam irradiation with very high NIR absorption was synthesized. These DNDs produced a 71-fold higher PA signal on a molar basis than similarly dimensioned gold nanorods, and 7.1 fmol of DNDs injected into rodents could be clearly imaged 3 mm below the skin surface with PA signal enhancement of 567% using an 820-nm laser wavelength.

  16. Multiscale modeling of high contrast brinkman equations with applications to deformable porous media

    KAUST Repository

    Brown, Donald

    2013-06-18

    Simulating porous media flows has a wide range of applications. Often, these applications involve many scales and multi-physical processes. A useful tool in the analysis of such problems in that of homogenization as an averaged description is derived circumventing the need for complicated simulation of the fine scale features. In this work, we recall recent developments of homogenization techniques in the application of flows in deformable porous media. In addition, homogenization of media with high-contrast. In particular, we recall the main ideas of the homogenization of slowly varying Stokes flow and summarize the results of [4]. We also present the ideas for extending these techniques to high-contrast deformable media [3]. These ideas are connected by the modeling of multiscale fluid-structure interaction problems. © 2013 American Society of Civil Engineers.

  17. High-contrast imaging of mycobacterium tuberculosis using third-harmonic generation microscopy

    Science.gov (United States)

    Kim, Bo Ram; Lee, Eungjang; Park, Seung-Han

    2015-07-01

    Nonlinear optical microcopy has become an important tool in investigating biomaterials due to its various advantages such as label-free imaging capabilities. In particular, it has been shown that third-harmonic generation (THG) signals can be produced at interfaces between an aqueous medium (e.g. cytoplasm, interstitial fluid) and a mineralized lipidic surface. In this work, we have demonstrated that label-free high-contrast THG images of the mycobacterium tuberculosis can be obtained using THG microscopy.

  18. High contrast soft tissue imaging based on multi-energy x-ray

    Science.gov (United States)

    Oh, Hyun-Hwa; Sung, Young-Hun; Kim, Sung-Su; Kwon, Jae-Hyun; Lee, Seong-Deok; Kim, Chang-Yeong

    2011-03-01

    Breast soft tissues have similar x-ray attenuations to mass tissue. Overlapping breast tissue structure often obscures mass and microcalcification, essential to the early detection of breast cancer. In this paper, we propose new method to generate the high contrast mammogram with distinctive features of a breast cancer by using multiple images with different x-ray energy spectra. On the experiments with mammography simulation and real breast tissues, the proposed method has provided noticeable images with obvious mass structure and microcalifications.

  19. GaAs/AlOx high contrast gratings for 980nm VCSELs

    Science.gov (United States)

    Gebski, M.; Dems, M.; Chen, J.; Qijie, W.; Dao Hua, Z.; Czyszanowski, T.

    2014-02-01

    In this paper we present results of computer optical simulations of VCSEL with modified high refractive index contrast grating (HCG) as a top mirror. We consider the HCG of two different designs which determine the lateral aperture. Such HCG mirror provides selective guiding effect. We show that proper design of aperture of HCG results in almost sixfold increase in cavity Q-factor for zero order mode and a discrimination of higher order modes.

  20. Simple approach for high-contrast optical imaging and characterization of graphene-based sheets

    OpenAIRE

    Jung, Inhwa; Pelton, Matthew; Piner, Richard; Dikin, Dmitriy A.; Stankovich, Sasha; Watcharotone, Supinda; Hausner, Martina; Ruoff, Rodney S.

    2007-01-01

    A simple optical method is presented for identifying and measuring the effective optical properties of nanometer-thick, graphene-based materials, based on the use of substrates consisting of a thin dielectric layer on silicon. High contrast between the graphene-based materials and the substrate is obtained by choosing appropriate optical properties and thickness of the dielectric layer. The effective refractive index and optical absorption coefficient of graphene oxide, thermally reduced grap...

  1. Highly accelerated first-pass contrast-enhanced magnetic resonance angiography of the peripheral vasculature: comparison of gadofosveset trisodium with gadopentetate dimeglumine contrast agents.

    Science.gov (United States)

    Maki, Jeffrey H; Wang, Maisie; Wilson, Gregory J; Shutske, Matthew G; Leiner, Tim

    2009-11-01

    To investigate the blood pool agent gadofosveset trisodium for first-pass, dynamic peripheral contrast-enhanced magnetic resonance angiography (pMRA), and compare the results with a conventional gadolinium contrast agent. A total of 16 patients were imaged at 1.5T using a prototype peripheral vascular coil with high SENSE acceleration. Five received gadopentetate dimeglumine ( approximately 0.25 mmol/kg), and 11 received gadofosveset trisodium (five standard-dose 0.03 mmol/kg, six high-dose 0.05 mmol/kg). Quantitative contrast-enhancement and qualitative image quality evaluation was compared between agents and doses. High-quality diagnostic images were uniformly obtained. The contrast ratio did not significantly differ between gadopentetate dimeglumine and high-dose gadofosveset trisodium, both of which were greater than standard-dose gadofosveset trisodium. High-dose gadofosveset trisodium was equivalent to gadopentetate dimeglumine in image quality and subjective vessel-to-background ratio, but significantly better for depicting small muscular arteries. Standard-dose gadofosveset trisodium showed equivalent image quality and small artery depiction with a slight but significant decrease in vessel-to-background ratio as compared to gadopentatate dimeglumine. Both gadofosveset trisodium doses trended toward more venous enhancement, but this was not a diagnostic problem. First-pass peripheral CE-MRA using gadofosveset trisodium is feasible, yielding image quality comparable to double to triple-dose gadopentetate dimeglumine. Increasing the gadofosveset trisodium dose to 0.05 mmol/kg yields further improvements.

  2. Development of bolometric tomography technique for high-contrast radiation distribution in toroidal devices

    Science.gov (United States)

    Sano, Ryuichi; Mukai, Kiyofumi; Peterson, Byron J.; Fukumoto, Masakatsu; Hoshino, Kazuo

    2017-09-01

    An extended Computed Tomography (CT) technique with a priori information based on Phillips-Tikhonov regularization has been developed to handle a high-contrast radiation distribution, which can result in large reconstruction errors in the region where radiation intensity is low, with few line of sight (LOS) data. Reference profiles generated from LOS data for every time slice are employed as the a priori information. In the extended technique, the weighting parameter for the reference profile is automatically determined from the LOS data, to avoid an inappropriate reference. The extended technique has been examined with a reconstruction test with the previously designed CT system using an infrared imaging video bolometer in JT-60SA. In the reconstructed profile of the high-contrast radiation distribution, the extended technique shows improvement of the weak radiation region, such as the scrape-off layer, without the deterioration of the strong radiation region, such as around the divertor. The results indicate that the extended CT technique can help to handle a high-contrast radiation distribution with few LOS data.

  3. Demonstration of symmetric dark holes using two deformable mirrors at the high-contrast imaging testbed

    Science.gov (United States)

    Riggs, A. J. Eldorado; Groff, Tyler D.; Carlotti, Alexis; Kasdin, N. Jeremy; Cady, Eric J.; Kern, Brian D.; Kuhnert, Andreas

    2013-09-01

    The High Contrast Imaging Laboratory (HCIL) at Princeton has developed several important algorithms and technologies for space-based coronagraphy missions to detect earth-like exoplanets. Before June 2013 the HCIL was the only facility with two deformable mirrors (DMs) in series for focal plane wavefront control, which allows for quasi-static speckle correction on both sides of the image plane. From June through August 2013, the High- Contrast Imaging Testbed (HCIT) at JPL had a second DM installed. In this paper we report on the results of our Technology Development for Exoplanet Missions project to achieve high contrast in two symmetric dark holes using a shaped pupil (SP) coronagraph at the HCIT. Our previous experiment with a similar SP at the HCIT in 2007 yielded single-sided dark holes. That experiment utilized an iterative, batch-process wavefront estimator and Electric Field Conjugation for wavefront control. Our current tests use the faster Kalman filter estimator and the stroke minimization control algorithm. We use the same ripple-style SPs as in the previous HCIT experiment because that mask manufacturing technique proved successful. Our tests of symmetric dark holes in monochromatic light at the HCIT demonstrate Princeton's steady improvements in wavefront control and estimation techniques for a space-based coronagraphy mission.

  4. Mode decomposition methods for flows in high-contrast porous media. Global-local approach

    KAUST Repository

    Ghommem, Mehdi

    2013-11-01

    In this paper, we combine concepts of the generalized multiscale finite element method (GMsFEM) and mode decomposition methods to construct a robust global-local approach for model reduction of flows in high-contrast porous media. This is achieved by implementing Proper Orthogonal Decomposition (POD) and Dynamic Mode Decomposition (DMD) techniques on a coarse grid computed using GMsFEM. The resulting reduced-order approach enables a significant reduction in the flow problem size while accurately capturing the behavior of fully-resolved solutions. We consider a variety of high-contrast coefficients and present the corresponding numerical results to illustrate the effectiveness of the proposed technique. This paper is a continuation of our work presented in Ghommem et al. (2013) [1] where we examine the applicability of POD and DMD to derive simplified and reliable representations of flows in high-contrast porous media on fully resolved models. In the current paper, we discuss how these global model reduction approaches can be combined with local techniques to speed-up the simulations. The speed-up is due to inexpensive, while sufficiently accurate, computations of global snapshots. © 2013 Elsevier Inc.

  5. A Highly Stable Marching-on-in-Time Volume Integral Equation Solver for Analyzing Transient Wave Interactions on High-Contrast Scatterers

    KAUST Repository

    Bagci, Hakan

    2014-01-06

    ). Numerical results demonstrate that this new MOT-VIE solver maintains its stability and accuracy even when used in analyzing transient wave interactions on high-contrast scatterers.

  6. High day- and night-time temperatures affect grain growth dynamics in contrasting rice genotypes.

    Science.gov (United States)

    Shi, Wanju; Yin, Xinyou; Struik, Paul C; Solis, Celymar; Xie, Fangming; Schmidt, Ralf C; Huang, Min; Zou, Yingbin; Ye, Changrong; Jagadish, S V Krishna

    2017-11-02

    Rice grain yield and quality are predicted to be highly vulnerable to global warming. Five genotypes including heat-tolerant and susceptible checks, a heat-tolerant near-isogenic line and two hybrids were exposed to control (31 °C/23 °C, day/night), high night-time temperature (HNT; 31 °C/30 °C), high day-time temperature (HDT; 38 °C/23 °C) and high day- and night-time temperature (HNDT; 38 °C/30 °C) treatments for 20 consecutive days during the grain-filling stage. Grain-filling dynamics, starch metabolism enzymes, temporal starch accumulation patterns and the process of chalk formation were quantified. Compensation between the rate and duration of grain filling minimized the impact of HNT, but irreversible impacts on seed-set, grain filling and ultimately grain weight were recorded with HDT and HNDT. Scanning electron microscopy demonstrated irregular and smaller starch granule formation affecting amyloplast build-up with HDT and HNDT, while a quicker but normal amylopast build-up was recorded with HNT. Our findings revealed temporal variation in the starch metabolism enzymes in all three stress treatments. Changes in the enzymatic activity did not derail starch accumulation under HNT when assimilates were sufficiently available, while both sucrose supply and the conversion of sucrose into starch were affected by HDT and HNDT. The findings indicate differential mechanisms leading to high day and high night temperature stress-induced loss in yield and quality. Additional genetic improvement is needed to sustain rice productivity and quality under future climates. © Society for Experimental Biology 2017.

  7. Topography improvements in MEMS DMs for high-contrast, high-resolution imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop and demonstrate an innovative microfabrication process to substantially improve the surface quality achievable in high-resolution...

  8. High contrast reflectance imaging of simulated lesions on tooth occlusal surfaces at near-IR wavelengths.

    Science.gov (United States)

    Fried, William A; Fried, Daniel; Chan, Kenneth H; Darling, Cynthia L

    2013-10-01

    In vivo and in vitro studies have shown that high contrast images of tooth demineralization can be acquired in the near-infrared (near-IR) without the interference of stain. The purpose of this study is to compare the lesion contrast in reflectance at near-IR wavelengths coincident with high water absorption with those in the visible, the near-IR at 1,300 nm and with fluorescence measurements for early lesions in occlusal surfaces. Twenty-four human molars were used in this in vitro study. Teeth were painted with an acid-resistant varnish, leaving a 4 × 4 mm window in the occlusal surface of each tooth exposed for demineralization. Artificial lesions were produced in the exposed windows after 1- and 2-day exposure to a demineralizing solution at pH 4.5. Lesions were imaged using near-IR reflectance at three wavelengths, 1,300, 1,460, and 1,600 nm using a high definition InGaAs camera. Visible light reflectance, and fluorescence with 405 nm excitation and detection at wavelengths greater than 500 nm were also used to acquire images for comparison. Crossed polarizers were used for reflectance measurements to reduce interference from specular reflectance. The contrast of both the 1- and 2-day lesions were significantly higher (P reflectance imaging at 1,460 and 1,600 nm than it was for near-IR reflectance imaging at 1,300 nm, visible reflectance imaging, and fluorescence. The markedly higher contrast at 1,460 and 1,600 nm wavelengths, coincident with higher water absorption, suggest that these wavelengths are better suited than 1,300 nm for imaging early/shallow demineralization on tooth surfaces. © 2013 Wiley Periodicals, Inc.

  9. Tunable Resonant-Cavity-Enhanced Photodetector with Double High-Index-Contrast Grating Mirrors

    DEFF Research Database (Denmark)

    Learkthanakhachon, Supannee; Yvind, Kresten; Chung, Il-Sug

    2013-01-01

    In this paper, we propose a broadband-tunable resonant-cavity-enhanced photodetector (RCE-PD) structure with double high-index-contrast grating (HCG) mirrors and numerically investigate its characteristics. The detector is designed to operate at 1550-nm wavelength. The detector structure consists...... of a top InP HCG mirror, a p-i-n photodiode embedding multiple quantum wells, and a Si HCG mirror formed in the Si layer of a silicon-on-insulator wafer. The detection wavelength can be changed by moving the top InP HCG mirror suspended in the air. High reflectivity and small penetration length of HCGs...

  10. High sensitivity contrast enhanced optical coherence tomography for functional in vivo imaging

    Science.gov (United States)

    Liba, Orly; SoRelle, Elliott D.; Sen, Debasish; de la Zerda, Adam

    2017-02-01

    In this study, we developed and applied highly-scattering large gold nanorods (LGNRs) and custom spectral detection algorithms for high sensitivity contrast-enhanced optical coherence tomography (OCT). We were able to detect LGNRs at a concentration as low as 50 pM in blood. We used this approach for noninvasive 3D imaging of blood vessels deep in solid tumors in living mice. Additionally, we demonstrated multiplexed imaging of spectrally-distinct LGNRs that enabled observations of functional drainage in lymphatic networks. This method, which we call MOZART, provides a platform for molecular imaging and characterization of tissue noninvasively at cellular resolution.

  11. Characterisation of a turbulent module for the MITHIC high-contrast imaging testbed

    Science.gov (United States)

    Vigan, A.; Postnikova, M.; Caillat, A.; Sauvage, J.-F.; Dohlen, K.; El Hadi, K.; Fusco, T.; Lamb, M.; N'Diaye, M.

    2016-07-01

    Future high-contrast imagers on ground-based extremely large telescopes will have to deal with the segmentation of the primary mirrors. Residual phase errors coming from the phase steps at the edges of the segments will have to be minimized in order to reach the highest possible wavefront correction and thus the best contrast performance. To study these effects, we have developed the MITHIC high-contrast testbed, which is designed to test various strategies for wavefront sensing, including the Zernike sensor for Extremely accurate measurements of Low-level Differential Aberrations (ZELDA) and COronagraphic Focal-plane wave-Front Estimation for Exoplanet detection (COFFEE). We recently equipped the bench with a new atmospheric turbulence simulation module that offers both static phase patterns representing segmented primary mirrors and continuous phase strips representing atmospheric turbulence filtered by an AO or an XAO system. We present a characterisation of the module using different instruments and wavefront sensors, and the first coronagraphic measurements obtained on MITHIC.

  12. Contrast MR of the brain after high-perfusion cardiopulmonary bypass

    Energy Technology Data Exchange (ETDEWEB)

    Simonson, T.M.; Yuh, W.T.C.; Hindman, B.J.; Embrey, R.P.; Halloran, J.I.; Behrendt, D.M. (Univ. of Iowa College of Medicine, Iowa City, IA (United States))

    1994-01-01

    To study the efficacy of contrast MR imaging in the evaluation of central nervous system complications in the cardiopulmonary bypass patient and attempt to explain their pathophysiology based on the MR appearance and the cardiopulmonary bypass protocol. Nineteen patients were prospectively studied with contrast MR examinations the day before and 3 to 7 days after cardiopulmonary bypass, to determine the nature, extent, and number of new postoperative MR abnormalities. Cardiopulmonary bypass parameters used in our institution included: membrane oxygenation, arterial filtration with a pore size of 25 [mu]m, and a relatively high perfusion rate to produce a cardiac index of 2.0 to 2.5 L min per m[sup 2]. The preoperative noncontrast MR examination showed age-related changes and/or signs of ischemia in 60% of patients on the day before surgery. However, there was no abnormal enhancement or new T2 abnormalities on any postoperative MR examination to suggest hypoperfusion or emboli. None of the 19 patients developed overt neurologic deficits postoperatively. Review of the cardiopulmonary bypass protocol used indicated significant variations in technique at different institutions. Contrast MR imaging demonstrated no new abnormalities in patients after cardiopulmonary bypass performed with strict in-line arterial filtration and relatively high perfusion. MR imaging is feasible in the early postoperative period after cardiopulmonary bypass and may offer a convenient method for evaluation of the neurologic impact of technical factors associated with cardiopulmonary bypass. 17 refs.

  13. Contrast sensitivity test and conventional and high frequency audiometry: information beyond that required to prescribe lenses and headsets

    Science.gov (United States)

    Comastri, S. A.; Martin, G.; Simon, J. M.; Angarano, C.; Dominguez, S.; Luzzi, F.; Lanusse, M.; Ranieri, M. V.; Boccio, C. M.

    2008-04-01

    In Optometry and in Audiology, the routine tests to prescribe correction lenses and headsets are respectively the visual acuity test (the first chart with letters was developed by Snellen in 1862) and conventional pure tone audiometry (the first audiometer with electrical current was devised by Hartmann in 1878). At present there are psychophysical non invasive tests that, besides evaluating visual and auditory performance globally and even in cases catalogued as normal according to routine tests, supply early information regarding diseases such as diabetes, hypertension, renal failure, cardiovascular problems, etc. Concerning Optometry, one of these tests is the achromatic luminance contrast sensitivity test (introduced by Schade in 1956). Concerning Audiology, one of these tests is high frequency pure tone audiometry (introduced a few decades ago) which yields information relative to pathologies affecting the basal cochlea and complements data resulting from conventional audiometry. These utilities of the contrast sensitivity test and of pure tone audiometry derive from the facts that Fourier components constitute the basis to synthesize stimuli present at the entrance of the visual and auditory systems; that these systems responses depend on frequencies and that the patient's psychophysical state affects frequency processing. The frequency of interest in the former test is the effective spatial frequency (inverse of the angle subtended at the eye by a cycle of a sinusoidal grating and measured in cycles/degree) and, in the latter, the temporal frequency (measured in cycles/sec). Both tests have similar duration and consist in determining the patient's threshold (corresponding to the inverse multiplicative of the contrast or to the inverse additive of the sound intensity level) for each harmonic stimulus present at the system entrance (sinusoidal grating or pure tone sound). In this article the frequencies, standard normality curves and abnormal threshold shifts

  14. Diffuse back-illumination setup for high temporally resolved extinction imaging

    DEFF Research Database (Denmark)

    Westlye, Fredrik Ree; Penney, Keith; Ivarsson, Anders

    2017-01-01

    This work presents the development of an optical setup for quantitative, high-temporal resolution line-of-sight extinction imaging in harsh optical environments. The application specifically targets measurements of automotive fuel sprays at high ambient temperature and pressure conditions where...

  15. High ambient contrast ratio OLED and QLED without a circular polarizer

    Science.gov (United States)

    Tan, Guanjun; Zhu, Ruidong; Tsai, Yi-Shou; Lee, Kuo-Chang; Luo, Zhenyue; Lee, Yuh-Zheng; Wu, Shin-Tson

    2016-08-01

    A high ambient contrast ratio display device using a transparent organic light emitting diode (OLED) or transparent quantum-dot light-emitting diode (QLED) with embedded multilayered structure and absorber is proposed and its performance is simulated. With the help of multilayered structure, the device structure allows almost all ambient light to get through the display device and be absorbed by the absorber. Because the reflected ambient light is greatly reduced, the ambient contrast ratio of the display system is improved significantly. Meanwhile, the multilayered structure helps to lower the effective refractive index, which in turn improves the out-coupling efficiency of the display system. Potential applications for sunlight readable flexible and rollable displays are emphasized.

  16. A New Standard for Assessing the Performance of High Contrast Imaging Systems

    Science.gov (United States)

    Jensen-Clem, Rebecca; Mawet, Dimitri; Gomez Gonzalez, Carlos A.; Absil, Olivier; Belikov, Ruslan; Currie, Thayne; Kenworthy, Matthew A.; Marois, Christian; Mazoyer, Johan; Ruane, Garreth; Tanner, Angelle; Cantalloube, Faustine

    2018-01-01

    As planning for the next generation of high contrast imaging instruments (e.g., WFIRST, HabEx, and LUVOIR, TMT-PFI, EELT-EPICS) matures and second-generation ground-based extreme adaptive optics facilities (e.g., VLT-SPHERE, Gemini-GPI) finish their principal surveys, it is imperative that the performance of different designs, post-processing algorithms, observing strategies, and survey results be compared in a consistent, statistically robust framework. In this paper, we argue that the current industry standard for such comparisons—the contrast curve—falls short of this mandate. We propose a new figure of merit, the “performance map,” that incorporates three fundamental concepts in signal detection theory: the true positive fraction, the false positive fraction, and the detection threshold. By supplying a theoretical basis and recipe for generating the performance map, we hope to encourage the widespread adoption of this new metric across subfields in exoplanet imaging.

  17. Ultra-High-Contrast Laser Acceleration of Relativistic Electrons in Solid Targets

    Energy Technology Data Exchange (ETDEWEB)

    Higginson, Drew Pitney [Univ. of California, San Diego, CA (United States)

    2013-01-01

    The cone-guided fast ignition approach to Inertial Con nement Fusion requires laser-accelerated relativistic electrons to deposit kilojoules of energy within an imploded fuel core to initiate fusion burn. One obstacle to coupling electron energy into the core is the ablation of material, known as preplasma, by laser energy proceeding nanoseconds prior to the main pulse. This causes the laser-absorption surface to be pushed back hundreds of microns from the initial target surface; thus increasing the distance that electrons must travel to reach the imploded core. Previous experiments have shown an order of magnitude decrease in coupling into surrogate targets when intentionally increasing the amount of preplasma. Additionally, for electrons to deposit energy within the core, they should have kinetic energies on the order of a few MeV, as less energetic electrons will be stopped prior to the core and more energetic electrons will pass through the core without depositing much energy. Thus a quantitative understanding of the electron energy spectrum and how it responds to varied laser parameters is paramount for fast ignition. For the rst time, this dissertation quantitatively investigates the acceleration of electrons using an ultra-high-contrast laser. Ultra-high-contrast lasers reduce the laser energy that reaches the target prior to the main pulse; drastically reducing the amount of preplasma. Experiments were performed in a cone-wire geometry relevant to fast ignition. These experiments irradiated the inner-tip of a Au cone with the laser and observed electrons that passed through a Cu wire attached to the outer-tip of the cone. The total emission of K x-rays is used as a diagnostic to infer the electron energy coupled into the wire. Imaging the x-ray emission allowed an e ective path-length of electrons within the wire to be determined, which constrained the electron energy spectrum. Experiments were carried out on the ultra-high-contrast Trident laser at Los

  18. Multi-parameter optimization of monolithic high-index contrast grating reflectors

    Science.gov (United States)

    Marciniak, Magdalena; Gebski, Marcin; Dems, Maciej; Wasiak, Michał; Czyszanowski, Tomasz

    2016-03-01

    Conventional High-index Contrast Gratings (HCG) consist of periodically distributed high refractive index stripes surrounded by low index media. Practically, such low/high index stack can be fabricated in several ways however low refractive index layers are electrical insulators of poor thermal conductivities. Monolithic High-index Contrast Gratings (MHCGs) overcome those limitations since they can be implemented in any material with a real refractive index larger than 1.75 without the need of the combination of low and high refractive index materials. The freedom of use of various materials allows to provide more efficient current injection and better heat flow through the mirror, in contrary to the conventional HCGs. MHCGs can simplify the construction of VCSELs, reducing their epitaxial design to monolithic wafer with carrier confinement and active region inside and etched stripes on both surfaces in post processing. We present numerical analysis of MHCGs using a three-dimensional, fully vectorial optical model. We investigate possible designs of MHCGs using multidimensional optimization of grating parameters for different refractive indices.

  19. Practical Considerations for High Spatial and Temporal Resolution Dynamic Transmission Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, M; Boyden, K; Browning, N D; Campbell, G H; Colvin, J D; DeHope, B; Frank, A M; Gibson, D J; Hartemann, F; Kim, J S; King, W E; LaGrange, T B; Pyke, B J; Reed, B W; Shuttlesworth, R M; Stuart, B C; Torralva, B R

    2006-05-01

    Although recent years have seen significant advances in the spatial resolution possible in the transmission electron microscope (TEM), the temporal resolution of most microscopes is limited to video rate at best. This lack of temporal resolution means that our understanding of dynamic processes in materials is extremely limited. High temporal resolution in the TEM can be achieved, however, by replacing the normal thermionic or field emission source with a photoemission source. In this case the temporal resolution is limited only by the ability to create a short pulse of photoexcited electrons in the source, and this can be as short as a few femtoseconds. The operation of the photo-emission source and the control of the subsequent pulse of electrons (containing as many as 5 x 10{sup 7} electrons) create significant challenges for a standard microscope column that is designed to operate with a single electron in the column at any one time. In this paper, the generation and control of electron pulses in the TEM to obtain a temporal resolution <10{sup -6} s will be described and the effect of the pulse duration and current density on the spatial resolution of the instrument will be examined. The potential of these levels of temporal and spatial resolution for the study of dynamic materials processes will also be discussed.

  20. Practical considerations for high spatial and temporal resolution dynamic transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, Michael R. [Materials Science and Technology Division, Chemistry and Materials Science Directorate, Lawrence Livermore National Laboratory, P.O. Box 808, L-356, Livermore, CA 94550 (United States)], E-mail: armstrong30@llnl.gov; Boyden, Ken [Materials Science and Technology Division, Chemistry and Materials Science Directorate, Lawrence Livermore National Laboratory, P.O. Box 808, L-356, Livermore, CA 94550 (United States); Browning, Nigel D. [Materials Science and Technology Division, Chemistry and Materials Science Directorate, Lawrence Livermore National Laboratory, P.O. Box 808, L-356, Livermore, CA 94550 (United States); Department of Chemical Engineering and Materials Science, University of California-Davis, One Shields Avenue, Davis, CA 95616 (United States); Campbell, Geoffrey H.; Colvin, Jeffrey D.; De Hope, William J.; Frank, Alan M. [Materials Science and Technology Division, Chemistry and Materials Science Directorate, Lawrence Livermore National Laboratory, P.O. Box 808, L-356, Livermore, CA 94550 (United States); Gibson, David J.; Hartemann, Fred [N Division, Physics and Advanced Technologies Directorate, Lawrence Livermore National Laboratory, P.O. Box 808, L-280, Livermore, CA 94550 (United States); Kim, Judy S. [Materials Science and Technology Division, Chemistry and Materials Science Directorate, Lawrence Livermore National Laboratory, P.O. Box 808, L-356, Livermore, CA 94550 (United States); Department of Chemical Engineering and Materials Science, University of California-Davis, One Shields Avenue, Davis, CA 95616 (United States); King, Wayne E.; La Grange, Thomas B.; Pyke, Ben J.; Reed, Bryan W.; Shuttlesworth, Richard M.; Stuart, Brent C.; Torralva, Ben R. [Materials Science and Technology Division, Chemistry and Materials Science Directorate, Lawrence Livermore National Laboratory, P.O. Box 808, L-356, Livermore, CA 94550 (United States)

    2007-04-15

    Although recent years have seen significant advances in the spatial resolution possible in the transmission electron microscope (TEM), the temporal resolution of most microscopes is limited to video rate at best. This lack of temporal resolution means that our understanding of dynamic processes in materials is extremely limited. High temporal resolution in the TEM can be achieved, however, by replacing the normal thermionic or field emission source with a photoemission source. In this case the temporal resolution is limited only by the ability to create a short pulse of photoexcited electrons in the source, and this can be as short as a few femtoseconds. The operation of the photo-emission source and the control of the subsequent pulse of electrons (containing as many as 5x10{sup 7} electrons) create significant challenges for a standard microscope column that is designed to operate with a single electron in the column at any one time. In this paper, the generation and control of electron pulses in the TEM to obtain a temporal resolution <10{sup -6} s will be described and the effect of the pulse duration and current density on the spatial resolution of the instrument will be examined. The potential of these levels of temporal and spatial resolution for the study of dynamic materials processes will also be discussed.

  1. Object Manifold Alignment for Multi-Temporal High Resolution Remote Sensing Images Classification

    Science.gov (United States)

    Gao, G.; Zhang, M.; Gu, Y.

    2017-05-01

    Multi-temporal remote sensing images classification is very useful for monitoring the land cover changes. Traditional approaches in this field mainly face to limited labelled samples and spectral drift of image information. With spatial resolution improvement, "pepper and salt" appears and classification results will be effected when the pixelwise classification algorithms are applied to high-resolution satellite images, in which the spatial relationship among the pixels is ignored. For classifying the multi-temporal high resolution images with limited labelled samples, spectral drift and "pepper and salt" problem, an object-based manifold alignment method is proposed. Firstly, multi-temporal multispectral images are cut to superpixels by simple linear iterative clustering (SLIC) respectively. Secondly, some features obtained from superpixels are formed as vector. Thirdly, a majority voting manifold alignment method aiming at solving high resolution problem is proposed and mapping the vector data to alignment space. At last, all the data in the alignment space are classified by using KNN method. Multi-temporal images from different areas or the same area are both considered in this paper. In the experiments, 2 groups of multi-temporal HR images collected by China GF1 and GF2 satellites are used for performance evaluation. Experimental results indicate that the proposed method not only has significantly outperforms than traditional domain adaptation methods in classification accuracy, but also effectively overcome the problem of "pepper and salt".

  2. Digital differential interference contrast autofocus for high-resolution oil-immersion microscopy.

    Science.gov (United States)

    Shen, Feimo; Hodgson, Louis; Price, Jeffrey H; Hahn, Klaus M

    2008-07-01

    Continued advances in cellular fluorescent biosensors enable studying intracellular protein dynamics in individual, living cells. Autofocus is valuable in such studies to compensate for temperature drift, uneven substrate over multiple fields of view, and cell growth during long-term high-resolution time-lapse studies of hours to days. Observing cellular dynamics with the highest possible resolution and sensitivity motivates the use of high numerical aperture (NA) oil-immersion objectives, and control of fluorescence exposure to minimize phototoxicity. To limit phototoxicity, to maximize light throughput of the objective for biosensor studies, and because phase contrast is distorted by the meniscus in microtiter plates, we studied autofocus in differential interference contrast (DIC) microscopy with a 60x 1.45 NA oil objective after removing the analyzer from the fluorescent light path. Based on a study of the experimental DIC modulation transfer function, we designed a new bandpass digital filter for measuring image sharpness. Repeated tests of DIC autofocus with this digital filter on 225 fields-of-view resulted in a precision of 8.6 nm (standard deviation). Autofocus trials on specimens with thicknesses from 9.47 to 33.20 mum, controlled by cell plating density, showed that autofocus precision was independent of specimen thickness. The results demonstrated that the selected spatial frequencies enabled very high-precision autofocus for high NA DIC automated microscopy, thereby potentially removing the problems of meniscus distortion in phase contrast imaging of microtiter plates and rendering the toxicity of additional fluorescence exposure unnecessary. (c) 2008 International Society for Advancement of Cytometry

  3. High-SNR multiple T2(*)-contrast magnetic resonance imaging using a robust denoising method based on tissue characteristics.

    Science.gov (United States)

    Eo, Taejoon; Kim, Taeseong; Jun, Yohan; Lee, Hongpyo; Ahn, Sung Soo; Kim, Dong-Hyun; Hwang, Dosik

    2017-06-01

    To develop an effective method that can suppress noise in successive multiecho T 2 (*)-weighted magnetic resonance (MR) brain images while preventing filtering artifacts. For the simulation experiments, we used multiple T 2 -weighted images of an anatomical brain phantom. For in vivo experiments, successive multiecho MR brain images were acquired from five healthy subjects using a multiecho gradient-recalled-echo (MGRE) sequence with a 3T MRI system. Our denoising method is a nonlinear filter whose filtering weights are determined by tissue characteristics among pixels. The similarity of the tissue characteristics is measured based on the l 2 -difference between two temporal decay signals. Both numerical and subjective evaluations were performed in order to compare the effectiveness of our denoising method with those of conventional filters, including Gaussian low-pass filter (LPF), anisotropic diffusion filter (ADF), and bilateral filter. Root-mean-square error (RMSE), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were used in the numerical evaluation. Five observers, including one radiologist, assessed the image quality and rated subjective scores in the subjective evaluation. Our denoising method significantly improves RMSE, SNR, and CNR of numerical phantom images, and CNR of in vivo brain images in comparison with conventional filters (P structure conspicuity (8.2 to 9.4 out of 10) and naturalness (9.2 to 9.8 out of 10) among the conventional filters in the subjective evaluation. This study demonstrates that high-SNR multiple T 2 (*)-contrast MR images can be obtained using our denoising method based on tissue characteristics without noticeable artifacts. Evidence level: 2 J. MAGN. RESON. IMAGING 2017;45:1835-1845. © 2016 International Society for Magnetic Resonance in Medicine.

  4. X-ray phase-contrast tomography for high-spatial-resolution zebrafish muscle imaging

    Science.gov (United States)

    Vågberg, William; Larsson, Daniel H.; Li, Mei; Arner, Anders; Hertz, Hans M.

    2015-11-01

    Imaging of muscular structure with cellular or subcellular detail in whole-body animal models is of key importance for understanding muscular disease and assessing interventions. Classical histological methods for high-resolution imaging methods require excision, fixation and staining. Here we show that the three-dimensional muscular structure of unstained whole zebrafish can be imaged with sub-5 μm detail with X-ray phase-contrast tomography. Our method relies on a laboratory propagation-based phase-contrast system tailored for detection of low-contrast 4-6 μm subcellular myofibrils. The method is demonstrated on 20 days post fertilization zebrafish larvae and comparative histology confirms that we resolve individual myofibrils in the whole-body animal. X-ray imaging of healthy zebrafish show the expected structured muscle pattern while specimen with a dystrophin deficiency (sapje) displays an unstructured pattern, typical of Duchenne muscular dystrophy. The method opens up for whole-body imaging with sub-cellular detail also of other types of soft tissue and in different animal models.

  5. VIP: Vortex Image Processing Package for High-contrast Direct Imaging

    Science.gov (United States)

    Gomez Gonzalez, Carlos Alberto; Wertz, Olivier; Absil, Olivier; Christiaens, Valentin; Defrère, Denis; Mawet, Dimitri; Milli, Julien; Absil, Pierre-Antoine; Van Droogenbroeck, Marc; Cantalloube, Faustine; Hinz, Philip M.; Skemer, Andrew J.; Karlsson, Mikael; Surdej, Jean

    2017-07-01

    We present the Vortex Image Processing (VIP) library, a python package dedicated to astronomical high-contrast imaging. Our package relies on the extensive python stack of scientific libraries and aims to provide a flexible framework for high-contrast data and image processing. In this paper, we describe the capabilities of VIP related to processing image sequences acquired using the angular differential imaging (ADI) observing technique. VIP implements functionalities for building high-contrast data processing pipelines, encompassing pre- and post-processing algorithms, potential source position and flux estimation, and sensitivity curve generation. Among the reference point-spread function subtraction techniques for ADI post-processing, VIP includes several flavors of principal component analysis (PCA) based algorithms, such as annular PCA and incremental PCA algorithms capable of processing big datacubes (of several gigabytes) on a computer with limited memory. Also, we present a novel ADI algorithm based on non-negative matrix factorization, which comes from the same family of low-rank matrix approximations as PCA and provides fairly similar results. We showcase the ADI capabilities of the VIP library using a deep sequence on HR 8799 taken with the LBTI/LMIRCam and its recently commissioned L-band vortex coronagraph. Using VIP, we investigated the presence of additional companions around HR 8799 and did not find any significant additional point source beyond the four known planets. VIP is available at http://github.com/vortex-exoplanet/VIP and is accompanied with Jupyter notebook tutorials illustrating the main functionalities of the library.

  6. Numerical Investigation of Vertical Cavity Lasers With High-Contrast Gratings Using the Fourier Modal Method

    DEFF Research Database (Denmark)

    Taghizadeh, Alireza; Mørk, Jesper; Chung, Il-Sug

    2016-01-01

    We explore the use of a modal expansion technique, Fourier modal method (FMM), for investigating the optical properties of vertical cavities employing high-contrast gratings (HCGs). Three techniques for determining the resonance frequency and quality factor (Q-factor) of a cavity mode are compared......, the scattering losses of several HCG-based vertical cavities with inplane heterostructures which have promising prospects for fundamental physics studies and on-chip laser applications, are investigated. This type of parametric study of 3D structures would be numerically very demanding using spatial...

  7. High-contrast grating reflectors for 980 nm vertical-cavity surface-emitting lasers

    Science.gov (United States)

    Gebski, M.; Kuzior, O.; Wasiak, M.; Szerling, A.; Wójcik-Jedlińska, A.; Pałka, N.; Dems, M.; Xie, Y. Y.; Xu, Z. J.; Wang, Q. J.; Zhang, D. H.; Czyszanowski, T.

    2015-02-01

    This paper presents results of computer simulation of 1D monolithic high refractive index contrast grating (MHCG) reflector also called surface grating reflector (SGR). We analyzed optical properties of the GaAs reflector designed for 980 nm wavelength with respect to the grating parameters variation. We also determined the electric field patterns after reflection from the structure in several cases of parameters variation. We show that thanks to the scalability and design simplicity, proposed design is a promising candidate for simple, next generation vertical cavity surface emitting lasers emitting from ultra-violet to infrared.

  8. High contrast imaging with the JWST-NIRSpec Integral Field Unit

    Science.gov (United States)

    Ygouf, Marie; Beichman, Charles A.; Hodapp, Klaus W.; Roellig, Thomas L.; NIRCam GTO

    2017-06-01

    With its integral field unit, the near-infrared spectrograph NIRSpec on JWST will allow to measure high-resolution spectra into the 3-5 μm range with an increased sensitivity over ground-based systems. This capability will considerably extend our knowledge of brown dwarfs and bright exoplanets at large separations from their host star. But because there is not any coronagraph on NIRSpec, the performance in term of contrast at close separation will be extremely limited. In this communication, we explore possibilities to further push this limitation by comparing different observing strategies and associated post-processing techniques.

  9. Probing ultrafast dynamics of solid-density plasma generated by high-contrast intense laser pulses

    Science.gov (United States)

    Jana, Kamalesh; Blackman, David R.; Shaikh, Moniruzzaman; Lad, Amit D.; Sarkar, Deep; Dey, Indranuj; Robinson, Alex P. L.; Pasley, John; Ravindra Kumar, G.

    2018-01-01

    We present ultrafast dynamics of solid-density plasma created by high-contrast (picosecond contrast ˜10-9), high-intensity (˜4 × 1018 W/cm2) laser pulses using time-resolved pump-probe Doppler spectrometry. Experiments show a rapid rise in blue-shift at early time delay (2-4.3 ps) followed by a rapid fall (4.3-8.3 ps) and then a slow rise in blue-shift at later time delays (>8.3 ps). Simulations show that the early-time observations, specifically the absence of any red-shifting of the reflected probe, can only be reproduced if the front surface is unperturbed by the laser pre-pulse at the moment that the high intensity pulse arrives. A flexible diagnostic which is capable of diagnosing the presence of low-levels of pre-plasma formation would be useful for potential applications in laser-produced proton and ion production, such as cancer therapy and security imaging.

  10. Recursive starlight and bias estimation for high-contrast imaging with an extended Kalman filter

    Science.gov (United States)

    Riggs, A. J. Eldorado; Kasdin, N. Jeremy; Groff, Tyler D.

    2016-01-01

    For imaging faint exoplanets and disks, a coronagraph-equipped observatory needs focal plane wavefront correction to recover high contrast. The most efficient correction methods iteratively estimate the stellar electric field and suppress it with active optics. The estimation requires several images from the science camera per iteration. To maximize the science yield, it is desirable both to have fast wavefront correction and to utilize all the correction images for science target detection. Exoplanets and disks are incoherent with their stars, so a nonlinear estimator is required to estimate both the incoherent intensity and the stellar electric field. Such techniques assume a high level of stability found only on space-based observatories and possibly ground-based telescopes with extreme adaptive optics. In this paper, we implement a nonlinear estimator, the iterated extended Kalman filter (IEKF), to enable fast wavefront correction and a recursive, nearly-optimal estimate of the incoherent light. In Princeton's High Contrast Imaging Laboratory, we demonstrate that the IEKF allows wavefront correction at least as fast as with a Kalman filter and provides the most accurate detection of a faint companion. The nonlinear IEKF formalism allows us to pursue other strategies such as parameter estimation to improve wavefront correction.

  11. Polarization-independent high-index contrast grating and its fabrication tolerances

    DEFF Research Database (Denmark)

    Ikeda, Kazuhiro; Takeuchi, Kazuma; Takayose, Kentaro

    2013-01-01

    A polarization-independent, high-index contrast grating (HCG) with a single layer of cross stripes allowing simple fabrication is proposed. Since the cross stripes structure can be suspended in air by selectively wet-etching the layer below, all the layers can be grown at once when implemented...... for vertical-cavity surface-emitting lasers. We optimized the structure to have a broad and high reflectivity band centered at around 1xA0;x3BC;m using a finite difference time domain method, and obtained an 80xA0;nm high reflectivity band centered at 0.97xA0;x3BC;m in which the reflectivity exceeded 99.5 We...

  12. Optimization of VCSELs incorporating monolithic subwavelength high-refractive-index contrast surface grating mirrors

    Science.gov (United States)

    Gebski, Marcin; Marciniak, Magdalena; Dems, Maciej; Czyszanowski, Tomasz; Lott, James A.

    2017-02-01

    We present results of computer simulations of vertical cavity surface emitting lasers (VCSELs) using novel, highreflectivity monolithic high refractive-index contrast grating (MHCG) mirrors and their more advanced version, partially covered by a thin metal layer - metallic MHCG (mMHCG) mirrors. The first experimental realization of this new class of mirrors is presented and discussed. We show that the metal layer does not deteriorate the high reflectivity of an mMHCG mirror, but in contrary, is a crucial element which allows high reflectivity and additionally opens a way for a more efficient electrical pumping of a VCSEL. Comparison of results of thermal-electrical-carrier-gain self-consistent simulations of both MHCG- and mMHCG-based VCSELs is presented and discussed. It is shown that using mHCG mirror as a top mirror of a VCSEL improves electrical characteristics and greatly decreases the differential resistance of the device.

  13. Scanning EM of non-heavy metal stained biosamples: Large-field of view, high contrast and highly efficient immunolabeling

    Energy Technology Data Exchange (ETDEWEB)

    Kuipers, Jeroen; Boer, Pascal de; Giepmans, Ben N.G., E-mail: b.n.g.giepmans@umcg.nl

    2015-10-01

    Scanning electron microscopy (SEM) is increasing its application in life sciences for electron density measurements of ultrathin sections. These are traditionally analyzed with transmission electron microscopy (TEM); by most labs, SEM analysis still is associated with surface imaging only. Here we report several advantages of SEM for thin sections over TEM, both for structural inspection, as well as analyzing immuno-targeted labels such as quantum dots (QDs) and gold, where we find that QD-labeling is ten times more efficient than gold-labeling. Furthermore, we find that omitting post-staining with uranyl and lead leads to QDs readily detectable over the ultrastructure, but under these conditions ultrastructural contrast was even almost invisible in TEM examination. Importantly, imaging in SEM with STEM detection leads to both outstanding QDs and ultrastructural contrast. STEM imaging is superior over back-scattered electron imaging of these non-contrasted samples, whereas secondary electron detection cannot be used at all. We conclude that examination of ultrathin sections by SEM, which may be immunolabeled with QDs, will allow rapid and straightforward analysis of large fields with more efficient labeling than can be achieved with immunogold. The large fields of view routinely achieved with SEM, but not with TEM, allows straightforward raw data sharing using virtual microscopy, also known as nanotomy when this concerns EM data in the life sciences. - Highlights: • High resolution and large fields of view via nanotomy or virtual microscopy. • Highly relevant for EM‐datasets where information density is high. • Sample preparation with low contrast good for STEM, not TEM. • Quantum dots now stand out in STEM‐based detection. • 10 Times more efficient labeling with quantum dots compared to gold.

  14. Modified ideal observer model (MIOM) for high-contrast and high-spatial resolution CT imaging tasks.

    Science.gov (United States)

    Cruz-Bastida, Juan P; Gomez-Cardona, Daniel; Garrett, John; Szczykutowicz, Timothy; Chen, Guang-Hong; Li, Ke

    2017-09-01

    Although a variety of mathematical observer models have been developed to predict human observer performance for low contrast lesion detection tasks, their predictive power for high contrast and high spatial resolution discrimination imaging tasks, including those in CT bone imaging, could be limited. The purpose of this work was to develop a modified observer model that has improved correlation with human observer performance for these tasks. The proposed observer model, referred to as the modified ideal observer model (MIOM), uses a weight function to penalize components in the task function that have less contribution to the actual human observer performance for high contrast and high spatial resolution discrimination tasks. To validate MIOM, both human observer and observer model studies were performed, each using exactly the same CT imaging task [discrimination of a connected component in a high contrast (1000 HU) high spatial resolution bone fracture model (0.3 mm)] and experimental CT image data. For the human observer studies, three physicist observers rated the connectivity of the fracture model using a five-point Likert scale; for the observer model studies, a total of five observer models, including both conventional models and the proposed MIOM, were used to calculate the discrimination capability of the CT images in resolving the connected component. Images used in the studies encompassed nine different reconstruction kernels. Correlation between human and observer model performance for these kernels were quantified using the Spearman rank correlation coefficient (ρ). After the validation study, an example application of MIOM was presented, in which the observer model was used to select the optimal reconstruction kernel for a High-Resolution (Hi-Res, GE Healthcare) CT scan technique. The performance of the proposed MIOM correlated well with that of the human observers with a Spearman rank correlation coefficient ρ of 0.88 (P = 0.003). In comparison

  15. Erythrocyte orientation and lung conductivity analysis with a high temporal resolution FEM model for bioimpedance measurements

    NARCIS (Netherlands)

    Ulbrich, M.; Paluchowski, P.; Muehlsteff, J.; Leonhardt, S.

    2012-01-01

    Impedance cardiography (ICG) is a simple and cheap method to acquirehemodynamic parameters. In this work, the influence of three dynamic physiological sources has been analyzed using a model of the humanthorax with a high temporal resolution. Therefore, simulations havebeen conducted using the

  16. High Relaxivity Gadolinium Hydroxypyridonate-Viral Capsid Conjugates: Nano-sized MRI Contrast Agents

    Energy Technology Data Exchange (ETDEWEB)

    Meux, Susan C.; Datta, Ankona; Hooker, Jacob M.; Botta, Mauro; Francis, Matthew B.; Aime, Silvio; Raymond, Kenneth N.

    2007-08-29

    High relaxivity macromolecular contrast agents based on the conjugation of gadolinium chelates to the interior and exterior surfaces of MS2 viral capsids are assessed. The proton nuclear magnetic relaxation dispersion (NMRD) profiles of the conjugates show up to a five-fold increase in relaxivity, leading to a peak relaxivity (per Gd{sup 3+} ion) of 41.6 mM{sup -1}s{sup -1} at 30 MHz for the internally modified capsids. Modification of the exterior was achieved through conjugation to flexible lysines, while internal modification was accomplished by conjugation to relatively rigid tyrosines. Higher relaxivities were obtained for the internally modified capsids, showing that (1) there is facile diffusion of water to the interior of capsids and (2) the rigidity of the linker attaching the complex to the macromolecule is important for obtaining high relaxivity enhancements. The viral capsid conjugated gadolinium hydroxypyridonate complexes appear to possess two inner-sphere water molecules (q = 2) and the NMRD fittings highlight the differences in the local motion for the internal ({tau}{sub RI} = 440 ps) and external ({tau}{sub RI} = 310 ps) conjugates. These results indicate that there are significant advantages of using the internal surface of the capsids for contrast agent attachment, leaving the exterior surface available for the installation of tissue targeting groups.

  17. Early-results from SHINE, the SPHERE High-Contrast Imaging Survey for Exoplanets

    Science.gov (United States)

    Langlois, M.

    2017-09-01

    With the development of high contrast imaging techniques and instruments, vast efforts have been devoted during the past decades to detect and characterize lighter, cooler and closer companions to nearby stars, and ultimately image new planetary systems. Complementary to other planet-hunting techniques, this approach has opened a new astrophysical window to study the physical properties and the formation mechanisms of brown dwarfs and planets. With the SPHERE XAO instrument first Light at VLT in May 2014, we have initiated with SHINE, the Sphere High-contrast-ImagiNg survey for Exoplanets, a systematic characterization of 400-600 young, nearby stars close environment aimed at hunting and studying the physical and statistical properties of the giant planet population at wide orbits (>5 AU) between 2015 and 2020. In this talk, we will briefly present the main properties of the SHINE sample, the observing and data reduction and analysis strategy, the current detection performances achieved with the combination of both near-infrared instruments IRDIS and IFS, finally the key early-results obtained so far with the characterization of giant planets, the study of planetary system architectures, finally the first exploitation of the statistical information after 2.5 years of operation.

  18. Current Status of the High Contrast Imager for Complex Aperture Telescopes (HiCAT) Testbed

    Science.gov (United States)

    Brooks, Keira; Brady, Gregory; Brito, Arturo; Comeau, Tom; Dillon, Thomas; Choquet, Elodie; Egron, Sylvain; Rob, Gontrum; John, Hagopian; Leboulleux, Lucie; Perrin, Marshall; Petrone, Peter; Pueyo, Laurent; Mazoyer, Johan; Moriarty, Christopher; N’Diaye, Mamadou; Eldorado Riggs, A. J.; Shiri, Ron; Sivaramakrishnan, Anand; St. Laurent, Kathryn; Valenzuela, Ana Maria; Zimmerman, Neil; Soummer, Remi; JHU Mechanical Engineering Senior Design Team

    2018-01-01

    The coming decades will bring the next space telescopes to take on the ambitious goal of exoplanet discovery via direct imaging, driving the development of innovative coronagraphic solutions. High contrast imager for Complex Aperture Telescopes (HiCAT) is an optical testbed meant to test such solutions for complex aperture telescopes, such as the Large UV/Optical/InfraRed surveyor (LUVOIR), or any other segmented space observatory. High contrast imaging becomes more demanding with the addition of segments, a secondary mirror obscuration, and support structure. LUVOIR, a candidate for the next-next generation major space telescope funded in part by NASA, will have all three. In the past year, HiCAT has made significant hardware and software updates in order to meet the needs of LUVOIR. In addition to completely overhauling the software that runs the testbed, we have received the first two custom-made apodizers for the Apodized Pupil Lyot Coronagraph (APLC) that we are testing for LUVOIR, and are continuing the development of the wavefront sensing and control. This poster will serve to give an update on these, and other, changes, as well as the most recent results.

  19. High-contrast laser acceleration of relativistic electrons in solid cone-wire targets

    Energy Technology Data Exchange (ETDEWEB)

    Higginson, D. P. [Univ. of California-San Diego, La Jolla, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Link, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sawada, H. [Univ. of California-San Diego, La Jolla, CA (United States); Wilks, S. C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chawla, S. R. [Univ. of California-San Diego, La Jolla, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chen, C. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jarrott, L. C. [Univ. of California-San Diego, La Jolla, CA (United States); Flippo, K. A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McLean, H. S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Patel, P. K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Perez, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Beg, F. N. [Univ. of California-San Diego, La Jolla, CA (United States); Bartal, T. [Univ. of California-San Diego, La Jolla, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wei, M. S. [General Atomics, San Diego, CA (United States)

    2015-12-31

    Optimization of electron coupling into small solid angles is of extreme importance to applications, such as Fast Ignition, that require maximum electron energy deposition within a small volume. To optimize this coupling, we use the ultra-high-contrast Trident laser, which remains below intensity of 1011 W/cm2 until < 0.1 ns before the main pulse, while still attaining high-energy, 75 J, and peak intensity of 5 x 1019 W/cm2. Using a cone-wire target, we find that the coupling into the 40 μm diameter wire is increased by a factor of 2.7x over the low-contrast Titan laser at similar peak intensity. Full-scale simulations are used to model the laser interaction and quantitatively reproduce the experimental results. These show that increase in coupling is due to both a closer interaction, as well as the reduction of laser filamentation and self-focusing.

  20. High-field magnetic resonance imaging of the human temporal lobe

    Directory of Open Access Journals (Sweden)

    Luis M. Colon-Perez

    2015-01-01

    Conclusions: Fresh ex vivo MR imaging, along with tractography, revealed complex intra-temporal structural variation corresponding to neuronal cell body layers, dendritic fields, and axonal projection systems evident histologically. This is the first study to describe in detail the human temporal lobe structural organization using high-field MR imaging and tractography. By preserving the 3-dimensional structures of the hippocampus and surrounding structures, specific changes in anatomy may inform us about the changes that occur in TLE in relation to the disease process and structural underpinnings in epilepsy-related memory dysfunction.

  1. Robust free-breathing SASHA T1 mapping with high-contrast image registration.

    Science.gov (United States)

    Chow, Kelvin; Yang, Yang; Shaw, Peter; Kramer, Christopher M; Salerno, Michael

    2016-08-17

    Many widely used myocardial T1 mapping sequences use breath-hold acquisitions that limit the precision of calculated T1 maps. The SAturation-recovery single-SHot Acquisition (SASHA) sequence has high accuracy with robustness against systematic confounders, but has poorer precision compared to the commonly used MOdified Look-Locker Inversion recovery (MOLLI) sequence. We propose a novel method for generating high-contrast SASHA images to enable a robust image registration approach to free-breathing T1 mapping with high accuracy and precision. High-contrast (HC) images were acquired in addition to primary variable flip angle (VFA) SASHA images by collecting an additional 15 k-space lines and sharing k-space data with the primary image. The number of free-breathing images and their saturation recovery times were optimized through numerical simulations. Accuracy and precision of T1 maps using the proposed SASHA-HC sequence was compared in 10 volunteers at 1.5 T to MOLLI, a breath-hold SASHA-VFA sequence, and free-breathing SASHA-VFA data processed using conventional navigator gating and standard image registration. Free-breathing T1 maps from 15 patients and 10 volunteers were graded by blinded observers for sharpness and artifacts. Difference images calculated by subtracting HC and primary SASHA images had greater tissue-blood contrast than the primary images alone, with a 3× improvement for 700 ms TS saturation recovery images and a 6× increase in tissue-blood contrast for non-saturated images. Myocardial T1s calculated in volunteers with free-breathing SASHA-HC were similar to standard breath-hold SASHA-VFA (1156.1 ± 28.1 ms vs 1149.4 ± 26.5 ms, p >0.05). The standard deviation of myocardial T1 values using a 108 s free-breathing SASHA-HC (36.2 ± 3.1 ms) was 50 % lower (p T1 map quality scores in volunteers were higher with SASHA-HC (4.7 ± 0.3 out of 5) than navigator gating (3.6 ± 0.4, p T1 maps had comparable precision to

  2. Ultra-high field upper extremity peripheral nerve and non-contrast enhanced vascular imaging.

    Directory of Open Access Journals (Sweden)

    Shailesh B Raval

    Full Text Available The purpose of this study was to explore the efficacy of Ultra-high field [UHF] 7 Tesla [T] MRI as compared to 3T MRI in non-contrast enhanced [nCE] imaging of structural anatomy in the elbow, forearm, and hand [upper extremity].A wide range of sequences including T1 weighted [T1] volumetric interpolate breath-hold exam [VIBE], T2 weighted [T2] double-echo steady state [DESS], susceptibility weighted imaging [SWI], time-of-flight [TOF], diffusion tensor imaging [DTI], and diffusion spectrum imaging [DSI] were optimized and incorporated with a radiofrequency [RF] coil system composed of a transverse electromagnetic [TEM] transmit coil combined with an 8-channel receive-only array for 7T upper extremity [UE] imaging. In addition, Siemens optimized protocol/sequences were used on a 3T scanner and the resulting images from T1 VIBE and T2 DESS were compared to that obtained at 7T qualitatively and quantitatively [SWI was only qualitatively compared]. DSI studio was utilized to identify nerves based on analysis of diffusion weighted derived fractional anisotropy images. Images of forearm vasculature were extracted using a paint grow manual segmentation method based on MIPAV [Medical Image Processing, Analysis, and Visualization].High resolution and high quality signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]-images of the hand, forearm, and elbow were acquired with nearly homogeneous 7T excitation. Measured [performed on the T1 VIBE and T2 DESS sequences] SNR and CNR values were almost doubled at 7T vs. 3T. Cartilage, synovial fluid and tendon structures could be seen with higher clarity in the 7T T1 and T2 weighted images. SWI allowed high resolution and better quality imaging of large and medium sized arteries and veins, capillary networks and arteriovenous anastomoses at 7T when compared to 3T. 7T diffusion weighted sequence [not performed at 3T] demonstrates that the forearm nerves are clearly delineated by fiber tractography. The

  3. Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue

    Energy Technology Data Exchange (ETDEWEB)

    Jakubek, Jan [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Granja, Carlos [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic)]. E-mail: carlos.granja@utef.cvut.cz; Dammer, Jiri [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Hanus, Robert [Institute of Organic Chemistry and Biochemistry, Academy of Sciences, CZ-166 10 Prague 6 (Czech Republic); Holy, Tomas [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Pospisil, Stanislav [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Tykva, Richard [Institute of Organic Chemistry and Biochemistry, Academy of Sciences, CZ-166 10 Prague 6 (Czech Republic); Uher, Josef [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Vykydal, Zdenek [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic)

    2007-02-01

    A tabletop system for digital high resolution and high sensitivity X-ray micro-radiography has been developed for small-animal and soft-tissue imaging. The system is based on a micro-focus X-ray tube and the semiconductor hybrid position sensitive Medipix2 pixel detector. Transmission radiography imaging, conventionally based only on absorption, is enhanced by exploiting phase-shift effects induced in the X-ray beam traversing the sample. Phase contrast imaging is realized by object edge enhancement. DAQ is done by a novel fully integrated USB-based readout with online image generation. Improved signal reconstruction techniques make use of advanced statistical data analysis, enhanced beam hardening correction and direct thickness calibration of individual pixels. 2D and 3D micro-tomography images of several biological samples demonstrate the applicability of the system for biological and medical purposes including in-vivo and time dependent physiological studies in the life sciences.

  4. Detection of admittivity anomaly on high-contrast heterogeneous backgrounds using frequency difference EIT.

    Science.gov (United States)

    Jang, J; Seo, J K

    2015-06-01

    This paper describes a multiple background subtraction method in frequency difference electrical impedance tomography (fdEIT) to detect an admittivity anomaly from a high-contrast background conductivity distribution. The proposed method expands the use of the conventional weighted frequency difference EIT method, which has been used limitedly to detect admittivity anomalies in a roughly homogeneous background. The proposed method can be viewed as multiple weighted difference imaging in fdEIT. Although the spatial resolutions of the output images by fdEIT are very low due to the inherent ill-posedness, numerical simulations and phantom experiments of the proposed method demonstrate its feasibility to detect anomalies. It has potential application in stroke detection in a head model, which is highly heterogeneous due to the skull.

  5. High-contrast red-green-blue tricolor fluorescence switching in bicomponent molecular film.

    Science.gov (United States)

    Kim, Hyeong-Ju; Whang, Dong Ryeol; Gierschner, Johannes; Lee, Chong Han; Park, Soo Young

    2015-03-27

    Highly efficient red-green-blue (RGB) tricolor luminescence switching was demonstrated in a bicomponent solid film consisting of (2Z,2'Z)-2,2'-(1,4-phenylene)bis(3-(4-butoxyphenyl)acrylonitrile) (DBDCS) and (2Z,2'Z)-3,3'-(2,5-bis(6-(9H-carbazol-9-yl)hexyloxy)-1,4-phenylene)bis(2-(3,5-bis(trifluoromethyl)phenyl)acrylonitrile) (m-BHCDCS). Reversible RGB luminescence switching with a high ratiometric color contrast (λ(em)=594, 527, 458 nm for red, green, and blue, respectively) was realized by different external stimuli such as heat, solvent vapor exposure, and mechanical force. It was shown that Förster resonance energy transfer in the bicomponent mixture could be efficiently switched on and off through supramolecular control. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Mathematical and computational modeling of a ferrofluid deformable mirror for high-contrast imaging

    Science.gov (United States)

    Lemmer, Aaron J.; Griffiths, Ian M.; Groff, Tyler D.; Rousing, Andreas W.; Kasdin, N. Jeremy

    2016-07-01

    Deformable mirrors (DMs) are an enabling and mission-critical technology in any coronagraphic instrument designed to directly image exoplanets. A new ferro fluid deformable mirror technology for high-contrast imaging is currently under development at Princeton, featuring a flexible optical surface manipulated by the local electromagnetic and global hydraulic actuation of a reservoir of ferro fluid. The ferro fluid DM is designed to prioritize high optical surface quality, high-precision/low-stroke actuation, and excellent low-spatial-frequency performance - capabilities that meet the unique demands of high-contrast coronagraphy in a space-based platform. To this end, the ferro-fluid medium continuously supports the DM face sheet, a configuration that eliminates actuator print-through (or, quilting) by decoupling the nominal surface figure from the geometry of the actuator array. The global pressure control allows independent focus actuation. In this paper we describe an analytical model for the quasi-static deformation response of the DM face sheet to both magnetic and pressure actuation. These modeling efforts serve to identify the key design parameters and quantify their contributions to the DM response, model the relationship between actuation commands and DM surface-profile response, and predict performance metrics such as achievable spatial resolution and stroke precision for specific actuator configurations. Our theoretical approach addresses the complexity of the boundary conditions associated with mechanical mounting of the face sheet, and makes use of asymptotic approximations by leveraging the three distinct length scales in the problem - namely, the low-stroke ( nm) actuation, face sheet thickness ( mm), and mirror diameter (cm). In addition to describing the theoretical treatment, we report the progress of computational multi physics simulations which will be useful in improving the model fidelity and in drawing conclusions to improve the design.

  7. High-contrast gratings for long-wavelength laser integration on silicon

    Science.gov (United States)

    Sciancalepore, Corrado; Descos, Antoine; Bordel, Damien; Duprez, Hélène; Letartre, Xavier; Menezo, Sylvie; Ben Bakir, Badhise

    2014-02-01

    Silicon photonics is increasingly considered as the most promising way-out to the relentless growth of data traffic in today's telecommunications infrastructures, driving an increase in transmission rates and computing capabilities. This is in fact challenging the intrinsic limit of copper-based, short-reach interconnects and microelectronic circuits in data centers and server architectures to offer enough modulation bandwidth at reasonable power dissipation. In the context of the heterogeneous integration of III-V direct-bandgap materials on silicon, optics with high-contrast metastructures enables the efficient implementation of optical functions such as laser feedback, input/output (I/O) to active/passive components, and optical filtering, while heterogeneous integration of III-V layers provides sufficient optical gain, resulting in silicon-integrated laser sources. The latest ensure reduced packaging costs and reduced footprint for the optical transceivers, a key point for the short reach communications. The invited talk will introduce the audience to the latest breakthroughs concerning the use of high-contrast gratings (HCGs) for the integration of III-V-on-Si verticalcavity surface-emitting lasers (VCSELs) as well as Fabry-Perot edge-emitters (EELs) in the main telecom band around 1.55 μm. The strong near-field mode overlap within HCG mirrors can be exploited to implement unique optical functions such as dense wavelength division multiplexing (DWDM): a 16-λ100-GHz-spaced channels VCSEL array is demonstrated. On the other hand, high fabrication yields obtained via molecular wafer bonding of III-V alloys on silicon-on-insulator (SOI) conjugate excellent device performances with cost-effective high-throughput production, supporting industrial needs for a rapid research-to-market transfer.

  8. SPHERE: exo-planets science with the new frontier of high contrast imaging

    Science.gov (United States)

    Claudi, R.; Beuzit, J.-L.; Feldt, M.; Mouillet, D.; Dohlen, K.; Puget, P.; Wildi, F.; Baruffolo, A.; Charton, J.; Antichi, J.; Boccaletti, A.; Desidera, S.; Fusco, T.; Gratton, R.; Langlois, M.; Mesa, D.; Pragt, J.; Raboub, P.; Roelfsema, R.; Saisse, M.; Schmid, H.-M.; Turatto, M.; Moutou, C.; Henning, T.; Udry, S.; Vakili, F.; Waters, R.

    2008-09-01

    ABSTRACT High contrast imaging will be the new frontier of exoplanets search providing the opportunity to have at once a deep glance in the neighborhood of the target star. In addition, coupling integral field spectrographs to extreme adaptive optics module at the focus of 8m telescope class and in future to ELTs, gives also the possibility to have a first order characterization of the exoplanets itself. SPHERE, second generation instrument for VLT, is an exo-solar planet imager, which goal is to detect giant exo-solar planets in the vicinity of bright stars and to characterize them through spectroscopic and polarimetric observations. It is a complete system with a core made of an extreme-Adaptive Optics (AO) turbulence correction, pupil tracker and interferential coronagraphs. At its back end, a differential dual imaging camera (IRDIS) and an integral field spectrograph (IFS) work in the Near Infrared (NIR) Y, J, H and Ks bands (0.95-2.32 μm) and a high resolution polarization camera (ZIMPOL) covers the visible (0.6 - 0.9 μm). The three instruments could work simultaneously. As matter of fact, as the instrument has been thought and designed, It should be considered more like an experiment than a typical ancillary instrumentation. The prime objective of SPHERE is the discovery and study of new planets orbiting stars by direct imaging of the circumstellar environment. The challenge consists in the very large contrast of luminosity between the star and the planet (larger than " 12.5 magnitudes or " 105 flux ratio), at very small angular separations, typically inside the seeing halo. The whole design of SPHERE is therefore optimized towards high contrast performance in a limited field of view and at short distances from the central star. Both evolved and young planetary systems will be detected, respectively through their reflected light (mostly by ZIMPOL) and through the intrinsic planet emission (IRDIS+IFS modes). Both components of the near-infrared arm of SPHERE

  9. High-speed rotational angioplasty-induced echo contrast in vivo and in vitro optical analysis.

    Science.gov (United States)

    Zotz, R J; Erbel, R; Philipp, A; Judt, A; Wagner, H; Lauterborn, W; Meyer, J

    1992-06-01

    High-speed rotational angioplasty is being evaluated as an alternative interventional device for the endovascular treatment of chronic coronary occlusions. It has been postulated that this type of angioplasty device may produce particulate debris or cavitations that induce myocardial ischemia. To determine the clinical presence of myocardial ischemia during rotational angioplasty, echocardiographic monitoring for wall motion abnormalities was performed in 9 patients undergoing rotational atheroablation using the Auth Rotablator for 10-sec intervals at 150,000 and 170,000 rpm. No wall motion abnormalities were detected in 5 patients evaluated with transesophageal echocardiography or in 4 patients monitored transthoracically, although AV block developed in one patient. Video intensitometry of the myocardial contrast effect for rotation times ranging from 3 to 20 sec found transient contrast enhancement of the myocardium supplied by the treated vessel. Intensity varied over time with half-time decay between 5.6 and 40 sec, indicating the likelihood of microcavitation. An in vitro model was constructed to measure the cavitation potential of the Auth Rotablator. A burr of 1.25 mm diameter rotating at 160,000 rpm achieves a velocity in excess of the 14.7 m/sec critical cavitation velocity. Testing the device in fresh human blood and distilled water produced microcavitations responsible for the enhanced echo effect, with the intensity and longevity of cavitation more pronounced in blood and proportional to the rotation time and speed. The mean size of the microcavitation bubbles in water was 90 +/- 33 (52-145) microns measured from photographs taken with a copper vapour laser emitting light pulses of 50 nsec duration as light source. The mean velocity of bubbles was found to be 0.62 +/- 0.30 ranging from 0.23 to 1.04 m/sec. It was measured via the motion of the bubbles during 5 laser pulses within 800 nsec. Clearly, microcavitations are associated with enhanced myocardial

  10. Comparison of synthetic high density lipoprotein (HDL) contrast agents for MR imaging of atherosclerosis.

    Science.gov (United States)

    Cormode, David P; Chandrasekar, Rohith; Delshad, Amanda; Briley-Saebo, Karen C; Calcagno, Claudia; Barazza, Alessandra; Mulder, Willem J M; Fisher, Edward A; Fayad, Zahi A

    2009-05-20

    Determining arterial macrophage expression is an important goal in the molecular imaging of atherosclerosis. Here, we compare the efficacy of two synthetic, high density lipoprotein (HDL) based contrast agents for magnetic resonance imaging (MRI) of macrophage burden. Each form of HDL was labeled with gadolinium and rhodamine to allow MRI and fluorescence microscopy. Either the 37 or 18 amino acid peptide replaced the apolipoprotein A-I in these agents, which were termed 37pA-Gd or 18A-Gd. The diameters of 37pA-Gd and 18A-Gd are 7.6 and 8.0 nm, respectively, while the longitudinal relaxivities are 9.8 and 10.0 (mM s)(-1). 37pA has better lipid binding properties. In vitro tests with J774A.1 macrophages proved the particles possessed the functionality of HDL by eliciting cholesterol efflux and were taken up in a receptor-like fashion by the cells. Both agents produced enhancements in atherosclerotic plaques of apolipoprotein E knockout mice of approximately 90% (n = 7 per agent) and are macrophage specific as evidenced by confocal microscopy on aortic sections. The half-lives of 37pA-Gd and 18A-Gd are 2.6 and 2.1 h, respectively. Despite the more favorable lipid interactions of 37pA, both agents gave similar, excellent contrast for the detection of atherosclerotic macrophages using MRI.

  11. Applications of focused MeV light ion beams for high resolution channeling contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, D.N.; Breese, M.B.H.; Prawer, S.; Dooley, S.P.; Allen, M.G.; Bettiol, A.A.; Saint, A. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Ryan, C.G. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1993-12-31

    The technique of Nuclear Microscopy, utilizing a focused ion probe of typically MeV H{sup +} or He{sup +} ions, can produce images where the contrast depends on typical Ion Beam Analysis (lBA) processes. The probe forming lens system usually utilizes strong focusing, precision magnetic quadrupole lenses and the probe is scanned over the target to produce images. Originally, this imaging technique was developed to utilize backscattered particles with incident beam currents typically of a few nA, and the technique became known as Channeling Contrast Microscopy (CCM). Recently, the technique has been developed further to utilize the forward scattering of ions incident along a major crystal axis in thin crystals. This technique is known as Channeling Scanning Transmission Ion Microscopy (CSTIM). Since nearly all incident ions are detected, CSTIM is highly efficient and very low beam currents are sufficient for imaging, typically as low as a few fA. This allows probes as small as 50 nm to be used. In this paper we briefly review the recent applications of these emerging techniques to a variety of single crystal materials (authors). 13 refs., 5 figs.

  12. Integrated Wavefront Correction and Bias Estimation for the High-Contrast Imaging of Exoplanets

    Science.gov (United States)

    Riggs, A. J. Eldorado

    Just over two decades ago the first planet outside our solar system was found, and thousands more have been discovered since. Nearly all these exoplanets were indirectly detected by sensing changes in their host stars' light. However, exoplanets must be directly imaged to determine their atmospheric compositions and the orbital parameters unavailable from only indirect detections. The main challenge of direct imaging is to observe stellar companions much fainter than the star and at small angular separations. Coronagraphy is one method of suppressing stellar diffraction to provide high star-to-planet contrast, but coronagraphs are extremely sensitive to quasi-static aberrations in the optical system. Active correction of the stellar wavefront is performed with deformable mirrors to recover high-contrast regions in the image. Estimation and control of the stellar electric field is performed iteratively in the camera's focal plane to avoid non-common path aberrations arising from a separate pupil sensor. Estimation can thus be quite time consuming because it requires several high-contrast intensity images per correction iteration. This thesis focuses on efficient focal plane wavefront correction (FPWC) for coronagraphy. Time is a precious commodity for a space telescope, so there is a strong incentive to reduce the total exposure time required for focal plane wavefront estimation. Much of our work emphasizes faster, more robust estimation via Kalman filtering, which optimally combines prior data with new measurements. The other main contribution of this thesis is a paradigm shift in the use of estimation images. Time for FPWC has generally been considered to be lost overhead, but we demonstrate that estimation images can be used for the detection and characterization of exoplanets and disks. These science targets are incoherent with their host stars, so we developed and implemented an iterated extended Kalman filter (IEKF) for simultaneous estimation of the stellar

  13. A High-precision Technique to Correct for Residual Atmospheric Dispersion in High-contrast Imaging Systems

    Science.gov (United States)

    Pathak, P.; Guyon, O.; Jovanovic, N.; Lozi, J.; Martinache, F.; Minowa, Y.; Kudo, T.; Takami, H.; Hayano, Y.; Narita, N.

    2016-12-01

    Direct detection and spectroscopy of exoplanets requires high-contrast imaging. For habitable exoplanets in particular, located at a small angular separation from the host star, it is crucial to employ small inner working angle (IWA) coronagraphs that efficiently suppress starlight. These coronagraphs, in turn, require careful control of the wavefront that directly impacts their performance. For ground-based telescopes, atmospheric refraction is also an important factor, since it results in a smearing of the point-spread function (PSF), that can no longer be efficiently suppressed by the coronagraph. Traditionally, atmospheric refraction is compensated for by an atmospheric dispersion compensator (ADC). ADC control relies on an a priori model of the atmosphere whose parameters are solely based on the pointing of the telescope, which can result in imperfect compensation. For a high-contrast instrument like the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system, which employs very small IWA coronagraphs, refraction-induced smearing of the PSF has to be less than 1 mas in the science band for optimum performance. In this paper, we present the first on-sky measurement and correction of residual atmospheric dispersion. Atmospheric dispersion is measured from the science image directly, using an adaptive grid of artificially introduced speckles as a diagnostic to feedback to the telescope’s ADC. With our current setup, we were able to reduce the initial residual atmospheric dispersion from 18.8 mas to 4.2 in broadband light (y- to H-band) and to 1.4 mas in the H-band only. This work is particularly relevant to the upcoming extremely large telescopes (ELTs) that will require fine control of their ADC to reach their full high-contrast imaging potential.

  14. High resolution three-dimensional cine phase contrast MRI of small intracranial aneurysms using a stack of stars k-space trajectory.

    Science.gov (United States)

    Kecskemeti, Steven; Johnson, Kevin; Wu, Yijing; Mistretta, Charles; Turski, Patrick; Wieben, Oliver

    2012-03-01

    To develop a method for targeted volumetric, three directional cine phase contrast (PC) imaging with high spatial resolution in clinically feasible scan times. A hybrid radial-Cartesian k-space trajectory is used for cardiac gated, volumetric imaging with three directional velocity encoding. Imaging times are reduced by radial undersampling and temporal viewsharing. Phase contrast angiograms are displayed in a new approach that addresses the concern of signal drop out in regions of slow flow. The feasibility of the PC stack of stars (SOS) trajectory was demonstrated with an in vivo study capturing 14 small intracranial aneurysms (2-10 mm). Aneurysm measures from six aneurysms also imaged with digital subtraction angiography (DSA) were compared with linear regression with those from the PC SOS images. All aneurysms were identified on the phase contrast angiograms. The geometric measures from PC SOS and DSA were in good agreement (linear regression: slope = 0.89, intercept = 0.35, R∧2 = 0.88). PC SOS is a promising method for obtaining volumetric angiograms and cine phase contrast velocity measurements in three dimensions. Acquired spatial resolutions of 0.4 × 0.4 × (0.7-1.0) mm make this method especially promising for studying flow in small intracranial aneurysms. Copyright © 2011 Wiley-Liss, Inc.

  15. An Improved Method for Producing High Spatial-Resolution NDVI Time Series Datasets with Multi-Temporal MODIS NDVI Data and Landsat TM/ETM+ Images

    Directory of Open Access Journals (Sweden)

    Yuhan Rao

    2015-06-01

    Full Text Available Due to technical limitations, it is impossible to have high resolution in both spatial and temporal dimensions for current NDVI datasets. Therefore, several methods are developed to produce high resolution (spatial and temporal NDVI time-series datasets, which face some limitations including high computation loads and unreasonable assumptions. In this study, an unmixing-based method, NDVI Linear Mixing Growth Model (NDVI-LMGM, is proposed to achieve the goal of accurately and efficiently blending MODIS NDVI time-series data and multi-temporal Landsat TM/ETM+ images. This method firstly unmixes the NDVI temporal changes in MODIS time-series to different land cover types and then uses unmixed NDVI temporal changes to predict Landsat-like NDVI dataset. The test over a forest site shows high accuracy (average difference: −0.0070; average absolute difference: 0.0228; and average absolute relative difference: 4.02% and computation efficiency of NDVI-LMGM (31 seconds using a personal computer. Experiments over more complex landscape and long-term time-series demonstrated that NDVI-LMGM performs well in each stage of vegetation growing season and is robust in regions with contrasting spatial and spatial variations. Comparisons between NDVI-LMGM and current methods (i.e., Spatial and Temporal Adaptive Reflectance Fusion Model (STARFM, Enhanced STARFM (ESTARFM and Weighted Linear Model (WLM show that NDVI-LMGM is more accurate and efficient than current methods. The proposed method will benefit land surface process research, which requires a dense NDVI time-series dataset with high spatial resolution.

  16. Fish as bioindicators for trace element pollution from two contrasting lakes in the Eastern Rift Valley, Kenya: spatial and temporal aspects.

    Science.gov (United States)

    Plessl, Christof; Otachi, Elick O; Körner, Wilfried; Avenant-Oldewage, Annemariè; Jirsa, Franz

    2017-08-01

    Lake Turkana and Lake Naivasha are two freshwater lakes in the Kenyan Rift Valley that differ significantly in water chemistry and anthropogenic influence: Lake Turkana is believed to be rather pristine and unpolluted, but a previous study has shown rather high levels of Li, Zn, and Cd in the migratory fish species Hydrocynus forskahlii, questioning this pristine status. Lake Naivasha is heavily influenced by agricultural activity in its catchment area and by direct water use, and high levels of metal pollutants have been reported in fish. This study presents the distribution of nine important trace elements in liver and muscle of the nonmigratory red belly tilapia Tilapia zillii from Lake Turkana and from Lake Naivasha (before and after a significant rise in water level due to as yet not fully understood reasons). In addition, trace element levels in the common carp Cyprinus carpio from Lake Naivasha are presented. Metal concentrations measured in the liver and muscle of T. zillii collected in Lake Turkana confirm the pristine status of the study site, but contrast with the results obtained for the migratory H. forskahlii. Comparing T. zillii from the two lakes reveals a clear difference in accumulation patterns between essential and nonessential trace elements: physiologically regulated essential elements are present in a very similar range in fish from both lakes, while levels of nonessential metals reflect short- or long-term exposure to those elements. The comparison of trace element concentrations in the fish samples from Lake Naivasha showed lower levels of most trace elements after the significant increase of the water level. This study demonstrates that fish are valuable bioindicators for evaluating trace element pollution even in contrasting lakes as long as the way-of-life habits of the species are taken into account.

  17. Contrast sensitivity with soft contact lenses compensated for spherical aberration in high ametropia.

    Science.gov (United States)

    De Brabander, J; Chateau, N; Bouchard, F; Guidollet, S

    1998-01-01

    In optical systems, it is usual to compensate for longitudinal spherical aberration. In order to increase image quality, lens surfaces can be made aspheric to bring all object light rays into focus at the image plane. Theoretically, soft contact lenses with high power and spherical surfaces show significant amounts of spherical aberration. The use of spherical aberration-free soft contact lenses could therefore improve retinal image quality in the case of high ametropia. However, because of ocular aberration, accommodation effects, pupil dynamics, contact lens flexure, and positioning, the computation of the spherical aberration induced when a contact lens is placed on the eye is complicated. In this study, the spatial contrast sensitivity (CS) of 61 high ametropes wearing soft contact lenses with, and without, in-air spherical aberration compensation is measured. A slightly better overall performance was found with the standard lenses. There was no significant influence by the type of ametropia, age, and gender. If individual results are considered, clinically significant differences between the two lens groups are observed in approximately 30% of the cases. It seems that correcting in-air soft contact lens spherical aberration systematically is of no clinical interest. However, selective manipulation of spherical aberration could, in high power soft contact lenses, significantly improve CS in individuals.

  18. Scaling Limit of Symmetric Random Walk in High-Contrast Periodic Environment

    Science.gov (United States)

    Piatnitski, A.; Zhizhina, E.

    2017-09-01

    The paper deals with the asymptotic properties of a symmetric random walk in a high contrast periodic medium in Z^d , d≥1 . From the existing homogenization results it follows that under diffusive scaling the limit behaviour of this random walk need not be Markovian. The goal of this work is to show that if in addition to the coordinate of the random walk in Z^d we introduce an extra variable that characterizes the position of the random walk inside the period then the limit dynamics of this two-component process is Markov. We describe the limit process and observe that the components of the limit process are coupled. We also prove the convergence in the path space for the said random walk.

  19. High contrast XMT studies of in-situ electrochemical dissolution of broken dental tools

    Science.gov (United States)

    Mills, David; Mitchell, Alison; Khine, Sean; Davis, Graham

    2016-10-01

    Fracture of nickel-titanium (NiTi) endodontic files is an uncommon but potentially damaging occurrence during root canal preparation. If the broken portion of the file remains inside the tooth canal it can prevent complete preparation of the root canal with consequent negative impact on treatment outcomes. Removal of file fragment from the tooth canal is currently a mechanical process, which due to the limited working space and restricted view can lead to further problems including perforation of the tooth. Electrochemical dissolution is a relatively new method proposed to dissolve a fractured instrument, fully or partially within the canal, to enable its removal. In this article we explore the effects of electrochemical dissolution on the root canal environment using high contrast time delay integration (TDI) X-ray micro-tomography (XMT) designed specifically for dental research.

  20. The Nonlinear Statistics of High-contrast Patches in Natural Images

    DEFF Research Database (Denmark)

    Lee, Ann; Pedersen, Kim Steenstrup; Mumford, David

    2003-01-01

    described. In this study, we explore the space of data points representing the values of 3 × 3 high-contrast patches from optical and 3D range images. We find that the distribution of data is extremely sparse with the majority of the data points concentrated in clusters and non-linear low......-dimensional manifolds. Furthermore, a detailed study of probability densities allows us to systematically distinguish between images of different modalities (optical versus range), which otherwise display similar marginal distributions. Our work indicates the importance of studying the full probability distribution...... of natural images, not just marginals, and the need to understand the intrinsic dimensionality and nature of the data. We believe that object-like structures in the world and the sensor properties of the probing device generate observations that are concentrated along predictable shapes in state space. Our...

  1. Scaling Limit of Symmetric Random Walk in High-Contrast Periodic Environment

    Science.gov (United States)

    Piatnitski, A.; Zhizhina, E.

    2017-11-01

    The paper deals with the asymptotic properties of a symmetric random walk in a high contrast periodic medium in Z^d, d≥1. From the existing homogenization results it follows that under diffusive scaling the limit behaviour of this random walk need not be Markovian. The goal of this work is to show that if in addition to the coordinate of the random walk in Z^d we introduce an extra variable that characterizes the position of the random walk inside the period then the limit dynamics of this two-component process is Markov. We describe the limit process and observe that the components of the limit process are coupled. We also prove the convergence in the path space for the said random walk.

  2. Multipath trapping dynamics of nanoparticles towards an integrated waveguide with a high index contrast

    Science.gov (United States)

    Tian, Hao; Kimerling, Lionel C.; Michel, Jurgen; Li, Guifang; Zhang, Lin

    2017-02-01

    Optical trapping and manipulation of nanoparticles in integrated photonics devices have recently received increasingly more attention and greatly facilitated the advances in lab-on-chip technologies. In this work, by solving motion equation numerically, we study the trapping dynamics of a nanoparticle near a high-index-contrast slot waveguide, under the influence of water flow perpendicular to the waveguide. It is shown that a nanoparticle can go along different paths before it gets trapped, strongly depending on its initial position relative to the integrated waveguide. Due to localized optical field enhancement on waveguide sidewalls, there are multiple trapping positions, with a critical area where particle trapping and transport are unstable. As the water velocity increases, the effective trapping range shrinks, but with a rate that is smaller than the increasing of water velocity. Finally, the trapping range is shown to decrease for smaller slot width that is below 100 nm, even though smaller slot width generates stronger local optical force.

  3. An optimal high contrast e-beam lithography process for the patterning of dense fin networks

    Energy Technology Data Exchange (ETDEWEB)

    Fruleux-Cornu, F. [Institut d' Electronique, de Microelectronique et de Nanotechnologie, CNRS UMR 8520, Avenue Poincare, BP 60069, 59652 Villeneuve d' Ascq cedex (France)]. E-mail: frederique.fruleux@isen.fr; Penaud, J. [Institut d' Electronique, de Microelectronique et de Nanotechnologie, CNRS UMR 8520, Avenue Poincare, BP 60069, 59652 Villeneuve d' Ascq cedex (France); Dubois, E. [Institut d' Electronique, de Microelectronique et de Nanotechnologie, CNRS UMR 8520, Avenue Poincare, BP 60069, 59652 Villeneuve d' Ascq cedex (France); Francois, M. [Institut d' Electronique, de Microelectronique et de Nanotechnologie, CNRS UMR 8520, Avenue Poincare, BP 60069, 59652 Villeneuve d' Ascq cedex (France); Muller, M. [Institut d' Electronique, de Microelectronique et de Nanotechnologie, CNRS UMR 8520, Avenue Poincare, BP 60069, 59652 Villeneuve d' Ascq cedex (France)

    2006-07-15

    There are many difficulties to overcome towards the integration of 10 nm CMOS technology. One such major challenge is to keep a tight control of the leakage current of devices while increasing the current drive at a reduced supply voltage. In this context, multi-gated structures, which are used to control the transport in ultra-thin channel (e.g. FinFET), are a promising solution. A critical step during the fabrication process of a FinFET is the patterning of dense, high aspect ratio fins. High demand is therefore placed on e-beam lithography techniques to obtain narrow, sharp, densely packed resist lines. This paper presents a detailed study on the optimum e-beam exposure process using a negative tone e-beam resist, namely Hydrogen Silsesquioxane (HSQ). The impact of the pre-exposure bake temperature, of the Tetramethyl Ammonium Hydroxide (TMAH) concentration in development solution and of development time has been investigated. The standard process uses 2.38% TMAH as a developer, samples being pre-baked on a hotplate at a temperature between 150 and 220 deg. C for 2 min. By using a lower pre-bake temperature of 90 deg. C and a more concentrated TMAH solution dosed at 25%, a seven-fold improvement of contrast can be obtained in terms of contrast values. Cross sectional SEM views show fin networks with a pitch ranging from 40 nm to 200 nm. The line profiles are steep and an excellent uniformity is obtained across the whole network, even for lines located at the edge. Dense patterns are presented with lines as narrow as 15 nm and with a 25 nm space.

  4. High-contrast fluorescence imaging in fixed and living cells using optimized optical switches.

    Directory of Open Access Journals (Sweden)

    Liangxing Wu

    Full Text Available We present the design, synthesis and characterization of new functionalized fluorescent optical switches for rapid, all-visible light-mediated manipulation of fluorescence signals from labelled structures within living cells, and as probes for high-contrast optical lock-in detection (OLID imaging microscopy. A triazole-substituted BIPS (TzBIPS is identified from a rational synthetic design strategy that undergoes robust, rapid and reversible, visible light-driven transitions between a colorless spiro- (SP and a far-red absorbing merocyanine (MC state within living cells. The excited MC-state of TzBIPS may also decay to the MC-ground state emitting near infra-red fluorescence, which is used as a sensitive and quantitative read-out of the state of the optical switch in living cells. The SP to MC transition for a membrane-targeted TzBIPS probe (C₁₂-TzBIPS is triggered at 405 nm at an energy level compatible with studies in living cells, while the action spectrum of the reverse transition (MC to SP has a maximum at 650 nm. The SP to MC transition is complete within the 790 ns pixel dwell time of the confocal microscope, while a single cycle of optical switching between the SP and MC states in a region of interest is complete within 8 ms (125 Hz within living cells, the fastest rate attained for any optical switch probe in a biological sample. This property can be exploited for real-time correction of background signals in living cells. A reactive form of TzBIPS is linked to secondary antibodies and used, in conjunction with an enhanced scope-based analysis of the modulated MC-fluorescence in immuno-stained cells, for high-contrast immunofluorescence microscopic analysis of the actin cytoskeleton.

  5. A hyper-temporal remote sensing protocol for high-resolution mapping of ecological sites.

    Science.gov (United States)

    Maynard, Jonathan J; Karl, Jason W

    2017-01-01

    Ecological site classification has emerged as a highly effective land management framework, but its utility at a regional scale has been limited due to the spatial ambiguity of ecological site locations in the U.S. or the absence of ecological site maps in other regions of the world. In response to these shortcomings, this study evaluated the use of hyper-temporal remote sensing (i.e., hundreds of images) for high spatial resolution mapping of ecological sites. We posit that hyper-temporal remote sensing can provide novel insights into the spatial variability of ecological sites by quantifying the temporal response of land surface spectral properties. This temporal response provides a spectral 'fingerprint' of the soil-vegetation-climate relationship which is central to the concept of ecological sites. Consequently, the main objective of this study was to predict the spatial distribution of ecological sites in a semi-arid rangeland using a 28-year time series of normalized difference vegetation index from Landsat TM 5 data and modeled using support vector machine classification. Results from this study show that support vector machine classification using hyper-temporal remote sensing imagery was effective in modeling ecological site classes, with a 62% correct classification. These results were compared to Gridded Soil Survey Geographic database and expert delineated maps of ecological sites which had a 51 and 89% correct classification, respectively. An analysis of the effects of ecological state on ecological site misclassifications revealed that sites in degraded states (e.g., shrub-dominated/shrubland and bare/annuals) had a higher rate of misclassification due to their close spectral similarity with other ecological sites. This study identified three important factors that need to be addressed to improve future model predictions: 1) sampling designs need to fully represent the range of both within class (i.e., states) and between class (i.e., ecological sites

  6. A Novel and Inexpensive Method for Measuring Volcanic Plume Water Fluxes at High Temporal Resolution

    Directory of Open Access Journals (Sweden)

    Tom D. Pering

    2017-02-01

    Full Text Available Water vapour (H2O is the dominant species in volcanic gas plumes. Therefore, measurements of H2O fluxes could provide valuable constraints on subsurface degassing and magmatic processes. However, due to the large and variable concentration of this species in the background atmosphere, little attention has been devoted to monitoring the emission rates of this species from volcanoes. Instead, the focus has been placed on remote measurements of SO2, which is present in far lower abundances in plumes, and therefore provides poorer single flux proxies for overall degassing conditions. Here, we present a new technique for the measurement of H2O emissions at degassing volcanoes at high temporal resolution (≈1 Hz, via remote sensing with low cost digital cameras. This approach is analogous to the use of dual band ultraviolet (UV cameras for measurements of volcanic SO2 release, but is focused on near infrared absorption by H2O. We report on the field deployment of these devices on La Fossa crater, Vulcano Island, and the North East Crater of Mt. Etna, during which in-plume calibration was performed using a humidity sensor, resulting in estimated mean H2O fluxes of ≈15 kg·s−1 and ≈34 kg·s−1, respectively, in accordance with previously reported literature values. By combining the Etna data with parallel UV camera and Multi-GAS observations, we also derived, for the first time, a combined record of 1 Hz gas fluxes for the three most abundant volcanic gas species: H2O, CO2, and SO2. Spectral analysis of the Etna data revealed oscillations in the passive emissions of all three species, with periods spanning ≈40–175 s, and a strong degree of correlation between the periodicity manifested in the SO2 and H2O data, potentially related to the similar exsolution depths of these two gases. In contrast, there was a poorer linkage between oscillations in these species and those of CO2, possibly due to the deeper exsolution of carbon dioxide, giving

  7. Contrasting Complement Control, Temporal Adjunct Control and Controlled Verbal Gerund Subjects in ASD: The Role of Contextual Cues in Reference Assignment.

    Science.gov (United States)

    Janke, Vikki; Perovic, Alexandra

    2017-01-01

    This study examines two complex syntactic dependencies (complement control and sentence-final temporal adjunct control) and one pragmatic dependency (controlled verbal gerund subjects) in children with ASD. Sixteen high-functioning (HFA) children (aged 6-16) with a diagnosis of autism and no language impairment, matched on age, gender and non-verbal MA to one TD control group, and on age, gender and verbal MA to another TD control group, undertook three picture-selection tasks. Task 1 measured their base-line interpretations of the empty categories (ec). Task 2 preceded these sentence sets with a weakly established topic cueing an alternative referent and Task 3 with a strongly established topic cueing an alternative referent. In complement control (Ron persuaded Hermione ec to kick the ball) and sentence-final temporal adjunct control (Harry tapped Luna while ec feeding the owl), the reference of the ec is argued to be related obligatorily to the object and subject respectively. In controlled verbal-gerund subjects (VGS) (ec Rowing the boat clumsily made Luna seasick), the ec's reference is resolved pragmatically. Referent choices across the three tasks were compared. TD children chose the object uniformly in complement control across all tasks but in adjunct control, preferences shifted toward the object in Task 3. In controlled VGSs, they exhibited a strong preference for an internal-referent interpretation in Task 1, which shifted in the direction of the cues in Tasks 2 and 3. HFA children gave a mixed performance. They patterned with their TD counterparts on complement control and controlled VGSs but performed marginally differently on adjunct control: no TD groups were influenced by the weakly established topic in Task 2 but all groups were influenced by the strongly established topic in Task 3. HFA children were less influenced than the TD children, resulting in their making fewer object choices overall but revealing parallel patterns of performance. In this

  8. A hardware architecture for real-time shadow removal in high-contrast video

    Science.gov (United States)

    Verdugo, Pablo; Pezoa, Jorge E.; Figueroa, Miguel

    2017-09-01

    Broadcasting an outdoor sports event at daytime is a challenging task due to the high contrast that exists between areas in the shadow and light conditions within the same scene. Commercial cameras typically do not handle the high dynamic range of such scenes in a proper manner, resulting in broadcast streams with very little shadow detail. We propose a hardware architecture for real-time shadow removal in high-resolution video, which reduces the shadow effect and simultaneously improves shadow details. The algorithm operates only on the shadow portions of each video frame, thus improving the results and producing more realistic images than algorithms that operate on the entire frame, such as simplified Retinex and histogram shifting. The architecture receives an input in the RGB color space, transforms it into the YIQ space, and uses color information from both spaces to produce a mask of the shadow areas present in the image. The mask is then filtered using a connected components algorithm to eliminate false positives and negatives. The hardware uses pixel information at the edges of the mask to estimate the illumination ratio between light and shadow in the image, which is then used to correct the shadow area. Our prototype implementation simultaneously processes up to 7 video streams of 1920×1080 pixels at 60 frames per second on a Xilinx Kintex-7 XC7K325T FPGA.

  9. Inference of selection based on temporal genetic differentiation in the study of highly polymorphic multigene families.

    Directory of Open Access Journals (Sweden)

    Mark McMullan

    Full Text Available The co-evolutionary arms race between host immune genes and parasite virulence genes is known as Red Queen dynamics. Temporal fluctuations in allele frequencies, or the 'turnover' of alleles at immune genes, are concordant with predictions of the Red Queen hypothesis. Such observations are often taken as evidence of host-parasite co-evolution. Here, we use computer simulations of the Major Histocompatibility Complex (MHC of guppies (Poecilia reticulata to study the turnover rate of alleles (temporal genetic differentiation, G'(ST. Temporal fluctuations in MHC allele frequencies can be ≥≤order of magnitude larger than changes observed at neutral loci. Although such large fluctuations in the MHC are consistent with Red Queen dynamics, simulations show that other demographic and population genetic processes can account for this observation, these include: (1 overdominant selection, (2 fluctuating population size within a metapopulation, and (3 the number of novel MHC alleles introduced by immigrants when there are multiple duplicated genes. Synergy between these forces combined with migration rate and the effective population size can drive the rapid turnover in MHC alleles. We posit that rapid allelic turnover is an inherent property of highly polymorphic multigene families and that it cannot be taken as evidence of Red Queen dynamics. Furthermore, combining temporal samples in spatial F(ST outlier analysis may obscure the signal of selection.

  10. High-speed quantitative phase imaging using time-stretch spectral shearing contrast (Conference Presentation)

    Science.gov (United States)

    Bosworth, Bryan; Foster, Mark A.

    2017-02-01

    Photonic time-stretch microscopy (TSM) provides an ideal platform for high-throughput imaging flow cytometry, affording extremely high shutter speeds and frame rates with high sensitivity. In order to resolve weakly scattering cells in biofluid and solve the issue of signal-to-noise in cell labeling specificity of biomarkers in imaging flow cytometry, several quantitative phase (QP) techniques have recently been adapted to TSM. However, these techniques have relied primarily on sensitive free-space optical configurations to generate full electric field measurements. The present work draws from the field of ultrashort pulse characterization to leverage the coherence of the ultrashort optical pulses integral to all TSM systems in order to do self-referenced single-shot quantitative phase imaging in a TSM system. Self-referencing is achieved via spectral shearing interferometry in an exceptionally stable and straightforward Sagnac loop incorporating an electro-optic phase modulator and polarization-maintaining fiber that produce sheared and unsheared copies of the pulse train with an inter-pulse delay determined by polarization mode dispersion. The spectral interferogram then yields a squared amplitude and a phase derivative image that can be integrated for conventional phase. We apply this spectral shearing contrast microscope to acquire QP images on a high-speed flow microscope at 90-MHz line rates with <400 pixels per line. We also consider the extension of this technique to compressed sensing (CS) acquisition by intensity modulating the interference spectra with pseudorandom binary waveforms to reconstruct the images from a highly sub-Nyquist number of random inner products, providing a path to even higher operating rates and reduced data storage requirements.

  11. High grade hemangioendothelioma of the temporal bone in a child: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Lim; Im, Soo Ah; Lim, Gye Yeon; Chun, Ho Jong; Lee, Hee Jeong; Park, Hyun Jin; Byun, Jae Young [The Catholic University of Korea, College of Medicine, Seoul (Korea, Republic of)

    2004-09-15

    Hemangioendothelioma is a rare vascular tumor characterized by endothelial tumor cells and variable malignant behavior, and it's not common for this lesion to involve the bone. Although there are a few reports of cranial involvement by hemangioendothelioma, only rare cases arising in temporal bone have been published. We present the radiologic findings of a 7-year-old boy who had a high grade hemangioendothelioma involving the temporal bone with intracranial extension. Evidence of flow voids on MR images suggested a tumor of vascular origin, and the ill-defined margins, cortical destruction and intracranial extension on the CT and MR images were correlated with the tumor's high histologic grade.

  12. Imaging Shock Waves in Diamond with Both High Temporal and Spatial Resolution at an XFEL.

    Science.gov (United States)

    Schropp, Andreas; Hoppe, Robert; Meier, Vivienne; Patommel, Jens; Seiboth, Frank; Ping, Yuan; Hicks, Damien G; Beckwith, Martha A; Collins, Gilbert W; Higginbotham, Andrew; Wark, Justin S; Lee, Hae Ja; Nagler, Bob; Galtier, Eric C; Arnold, Brice; Zastrau, Ulf; Hastings, Jerome B; Schroer, Christian G

    2015-06-18

    The advent of hard x-ray free-electron lasers (XFELs) has opened up a variety of scientific opportunities in areas as diverse as atomic physics, plasma physics, nonlinear optics in the x-ray range, and protein crystallography. In this article, we access a new field of science by measuring quantitatively the local bulk properties and dynamics of matter under extreme conditions, in this case by using the short XFEL pulse to image an elastic compression wave in diamond. The elastic wave was initiated by an intense optical laser pulse and was imaged at different delay times after the optical pump pulse using magnified x-ray phase-contrast imaging. The temporal evolution of the shock wave can be monitored, yielding detailed information on shock dynamics, such as the shock velocity, the shock front width, and the local compression of the material. The method provides a quantitative perspective on the state of matter in extreme conditions.

  13. Pulsed EM Field Response of a Thin, High-Contrast, Finely Layered Structure With Dielectric and Conductive Properties

    NARCIS (Netherlands)

    De Hoop, A.T.; Jiang, L.

    2009-01-01

    The response of a thin, high-contrast, finely layered structure with dielectric and conductive properties to an incident, pulsed, electromagnetic field is investigated theoretically. The fine layering causes the standard spatial discretization techniques to solve Maxwell's equations numerically to

  14. Risk factors associated with spatio-temporal clusters of high mortality in Danish swine herds

    DEFF Research Database (Denmark)

    Lopes Antunes, Ana Carolina; Ersbøll, Annette; Bihrmann, Kristine

    What were our motivation and objective? Mortality data are recorded to fulfill the European Commission requirements which ensures a continuous data flow for a surveillance system. Before using these data as part of a syndromic surveillance system, it is necessary to understand why increasing...... changes in mortality happen. The aim of this study was to identify spatio-temporal clusters of high mortality in Danish swine herds and associated risk factors....

  15. Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function.

    Science.gov (United States)

    Goebel, Juliane; Nensa, Felix; Schemuth, Haemi P; Maderwald, Stefan; Gratz, Marcel; Quick, Harald H; Schlosser, Thomas; Nassenstein, Kai

    2016-08-01

    To assess two compressed sensing cine magnetic resonance imaging (MRI) sequences with high spatial or high temporal resolution in comparison to a reference steady-state free precession cine (SSFP) sequence for reliable quantification of left ventricular (LV) volumes. LV short axis stacks of two compressed sensing breath-hold cine sequences with high spatial resolution (SPARSE-SENSE HS: temporal resolution: 40 msec, in-plane resolution: 1.0 × 1.0 mm(2) ) and high temporal resolution (SPARSE-SENSE HT: temporal resolution: 11 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) and of a reference cine SSFP sequence (standard SSFP: temporal resolution: 40 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) were acquired in 16 healthy volunteers on a 1.5T MR system. LV parameters were analyzed semiautomatically twice by one reader and once by a second reader. The volumetric agreement between sequences was analyzed using paired t-test, Bland-Altman plots, and Passing-Bablock regression. Small differences were observed between standard SSFP and SPARSE-SENSE HS for stroke volume (SV; -7 ± 11 ml; P = 0.024), ejection fraction (EF; -2 ± 3%; P = 0.019), and myocardial mass (9 ± 9 g; P = 0.001), but not for end-diastolic volume (EDV; P = 0.079) and end-systolic volume (ESV; P = 0.266). No significant differences were observed between standard SSFP and SPARSE-SENSE HT regarding EDV (P = 0.956), SV (P = 0.088), and EF (P = 0.103), but for ESV (3 ± 5 ml; P = 0.039) and myocardial mass (8 ± 10 ml; P = 0.007). Bland-Altman analysis showed good agreement between the sequences (maximum bias ≤ -8%). Two compressed sensing cine sequences, one with high spatial resolution and one with high temporal resolution, showed good agreement with standard SSFP for LV volume assessment. J. Magn. Reson. Imaging 2016;44:366-374. © 2016 Wiley Periodicals, Inc.

  16. [Comparison of diagnostic quality in hysterosalpingography between iodinated non-ionic contrast media with low and high osmolarity].

    Science.gov (United States)

    Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V

    Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.

  17. Spatial and temporal variations of the high-altitude cusp precipitation

    Directory of Open Access Journals (Sweden)

    Z. Němeček

    2004-07-01

    Full Text Available Structured dispersion patterns of the ion precipitation in low- and mid-altitude cusp regions have been reported by many authors. These patterns are interpreted either as temporal features in terms of the pulsed reconnection model or as spatial changes caused by a combination of the particle velocity with the convection of magnetic field lines. It is generally expected that the spatial dispersion is predominantly observed in lower altitudes where the spacecraft crosses a wide range of geomagnetic coordinates in a short time, whereas the high-altitude spacecraft observes temporal changes because it stays nearly on the same field line for a long time. We have analyzed one pass of the INTERBALL-1/MAGION-4 satellite pair through the high-altitude cusp and found that both temporal and spatial dispersion effects are important even in the magnetopause vicinity. The analysis of the present event shows a spatial nature of the observed dispersion in the LLBL and in the plasma mantle. We have identified two sources of a mantle precipitation operating simultaneously. Our investigations suggest that besides already reported latitudinal dispersion, the longitudinal dispersion can be observed during intervals of sufficiently high east-west interplanetary magnetic field component.

  18. High aspect ratio gratings for X-ray phase contrast imaging

    Science.gov (United States)

    Mohr, Jürgen; Grund, Thomas; Kunka, Danays; Kenntner, Johannes; Leuthold, Juerg; Meiser, Jan; Schulz, Joachim; Walter, Marco

    2012-07-01

    Differential phase contrast X-ray imaging (DPCI) has gained a lot of interest in the past years. It is based on X-ray grating interferometry and the image quality is strongly dependant on the grating quality. Periodic line and space structures with periods in the micron range are required for the source and absorption grating. In case of energies > 30 keV their height should be larger than 100 μm resulting in aspect ratios of more than 100. Deep X-ray lithography and gold electroforming (LIGA technology) is used to fabricate these challenging structures. After resist, design and process optimization gratings with 2.4 μm period have been electroformed up to 120 μm, Visibilities of up to 70% for 29 keV and up to 20% for 52 keV have been achieved for monochromatic synchrotron light. Structures with larger periods could be manufactured up to 200 μm; further increase of the height and the gratings quality is possible yielding to high performance gratings also for high energies.

  19. Innovations in contrast enhanced high resolution ultrasound improve sonographic imaging of the intestine.

    Science.gov (United States)

    Girlich, C; Schacherer, D; Lamby, P; Scherer, M N; Schreyer, A G; Jung, E M

    2010-01-01

    The aim was to describe the perfusion pattern of the inflamed bowel wall and the surrounding tissue in inflammatory bowel disease and diverticulitis of the sigmoid colon applying a high resolution matrix transducer and the new hybrid technique. We performed contrast enhanced ultrasound (CEUS) using an updated version of the 1-5 MHz (C1-5-D convex probe) and the 6-9 MHz probe (9L-D linear probe) as well as a matrix 6-15 MHz transducer (ML 6-15-D Matrix Array Linear Probe) and updated post-processing procedures to examine microvascularization of inflamed bowel wall in Crohn's disease (11 patients), ulcerative colitis (1 patient) and diverticulitis of the sigmoid colon (2 patients). Assessment of mural microvascularization was successful as well as identification of fistulas (2 patients) and covered perforation (1 patient). Moreover analysis of time intensity curves revealed increase of signal intensity up to 20 dB. Summarizing, application of high resolution linear probes and use of updated post-processing methods substantially improve detection of inflammation-caused increased microcirculation of the bowel wall and the surrounding tissue as well as identification of complications as fistulas or covered perforations.

  20. Implantation of high concentration noble gases in cubic zirconia and silicon carbide: A contrasted radiation tolerance

    Energy Technology Data Exchange (ETDEWEB)

    Velişa, Gihan, E-mail: gihan@tandem.nipne.ro [Horia Hulubei National Institute for Physics and Nuclear Engineering, P.O.B. MG-6, 077125 Magurele (Romania); Debelle, Aurélien; Thomé, Lionel; Mylonas, Stamatis [Centre de Sciences Nucléaires et de Sciences de la Matière, CNRS-IN2P3-Université Paris-Sud, Bât. 108, F-91405 Orsay (France); Vincent, Laetitia [Centre de Sciences Nucléaires et de Sciences de la Matière, CNRS-IN2P3-Université Paris-Sud, Bât. 108, F-91405 Orsay (France); Institut d’Electronique Fondamentale, Université Paris-Sud, UMR 8622, Bât. 220, 91405 Orsay (France); Boulle, Alexandre [Science des Procédés Céramiques et de Traitements de Surface, CNRS UMR 7315, Centre Européen de la Céramique, 12 rue Atlantis, 87068 Limoges (France); Jagielski, Jacek [Institute for Electronic Materials Technology, Wolczynska 133, 01-919 Warsaw (Poland); National Center for Nuclear Research, PL-05-400 Swierk/Otwock (Poland); Pantelica, Dan [Horia Hulubei National Institute for Physics and Nuclear Engineering, P.O.B. MG-6, 077125 Magurele (Romania)

    2014-08-01

    The modifications of the microstructure of yttria-stabilized cubic zirconia and silicon carbide single crystals implanted with high concentrations of noble gas ions and subsequently annealed at high temperature were characterized using RBS/C, XRD and TEM. It is found that the annealing behavior is strongly dependent on both the material and the implanted noble gases. Ar-implanted yttria-stabilized zirconia shows no significant microstructural modification upon annealing at 800 °C, e.g. dislocations are still present and the size of the Ar bubbles does not evolve. This is in strong contrast with previous observations on helium-implanted zirconia, where the formation of bubbles and elongated fractures were observed. In the case of SiC, thermal annealing at 1000 °C shows an enhanced damage recovery when He is implanted as compared to Ar implantation and the recrystallization of the matrix is accompanied with the release of noble gas atoms. This difference can be ascribed to different atomic radii, and thus mobility of implanted species.

  1. Two dimensional analysis of finite size high-contrast gratings for applications in VCSELs.

    Science.gov (United States)

    Liu, Anjin; Hofmann, Werner; Bimberg, Dieter

    2014-05-19

    2-dimensional simulations of high-contrast gratings (HCGs) of finite size are carried out, targeting at their applications in vertical-cavity surface-emitting lasers (VCSELs). Finite HCGs show a very different behavior from infinite grating ones. The reflectivity of a finite HCG strongly depends on the HCG size and the source size. Our simulation results predict finite reflectivity and transmission values, well consistent with reported experimental results. The band of high reflectivity (>99.5%) of finite HCGs is less broad as compared to the infinite case. Losses into a guided mode excited in the HCG plane are identified as being at the root. This guided mode is excited due to the nonzero angular components in the finite source size, and greatly enhances the transmission and the light leakage from the slab. In addition, the simulation results show that the details of the finite HCG can shape the output beam, whilst a Gaussian-like reflected wave is typically achieved. Our simulations can explain the current discrepancies between numerical predictions of reflectivities approaching 100% and working HCG-VCSELs showing finite reflectivities and nearly Gaussian-like output. Consequently, our analysis of finite HCGs is indispensable for HCG-VCSEL design.

  2. High-contrast visualization of graphene oxide on dye-sensitized glass, quartz, and silicon by fluorescence quenching.

    Science.gov (United States)

    Treossi, Emanuele; Melucci, Manuela; Liscio, Andrea; Gazzano, Massimo; Samorì, Paolo; Palermo, Vincenzo

    2009-11-04

    We present a novel approach for detecting and visualizing graphene oxide (GO) with high contrast on different substrates, including glass, quartz, and silicon. Visualization of GO sheets is accomplished through quenching the fluorescence of a thiophene dye, giving high optical contrast without the need to use interference methods. A comparison of fluorescence, AFM, and XRD measurements confirmed that even a single GO sheet can completely quench the fluorescence and thus be quickly visualized.

  3. On filtration for high-energy phase-contrast x-ray imaging

    Science.gov (United States)

    Riess, Christian; Mohamed, Ashraf; Hinshaw, Waldo; Fahrig, Rebecca

    2015-03-01

    Phase-sensitive x-ray imaging promises unprecedented soft-tissue contrast and resolution. However, several practical challenges have to be overcome when using the setup in a clinical environment. The system design that is currently closest to clinical use is the grating-based Talbot-Lau interferometer (GBI).1-3 The requirements for patient imaging are low patient dose, fast imaging time, and high image quality. For GBI, these requirements can be met most successfully with a narrow energy width, high- ux spectrum. Additionally, to penetrate a human-sized object, the design energy of the system has to be well above 40 keV. To our knowledge, little research has been done so far to investigate optimal GBI filtration at such high x-ray energies. In this paper, we study different filtration strategies and their impact on high-energy GBI. Specifically, we compare copper filtration at low peak voltage with equal-absorption, equal-imaging time K-edge filtration of spectra with higher peak voltage under clinically realistic boundary conditions. We specifically focus on a design energy of 59 keV and investigate combinations of tube current, peak voltage, and filtration that lead to equal patient absorption. Theoretical considerations suggest that the K edge of tantalum might provide a transmission pocket at around 59 keV, yielding a well-shaped spectrum. Although one can observe a slight visibility benefit when using tungsten or tantalum filtration, experimental results indicate that visibility benefits most from a low x-ray tube peak voltage.

  4. Automatic temporal expectancy: a high-density event-related potential study.

    Directory of Open Access Journals (Sweden)

    Giovanni Mento

    Full Text Available How we compute time is not fully understood. Questions include whether an automatic brain mechanism is engaged in temporally regular environmental structure in order to anticipate events, and whether this can be dissociated from task-related processes, including response preparation, selection and execution. To investigate these issues, a passive temporal oddball task requiring neither time-based motor response nor explicit decision was specifically designed and delivered to participants during high-density, event-related potentials recording. Participants were presented with pairs of audiovisual stimuli (S1 and S2 interspersed with an Inter-Stimulus Interval (ISI that was manipulated according to an oddball probabilistic distribution. In the standard condition (70% of trials, the ISI lasted 1,500 ms, while in the two alternative, deviant conditions (15% each, it lasted 2,500 and 3,000 ms. The passive over-exposition to the standard ISI drove participants to automatically and progressively create an implicit temporal expectation of S2 onset, reflected by the time course of the Contingent Negative Variation response, which always peaked in correspondence to the point of S2 maximum expectation and afterwards inverted in polarity towards the baseline. Brain source analysis of S1- and ISI-related ERP activity revealed activation of sensorial cortical areas and the supplementary motor area (SMA, respectively. In particular, since the SMA time course synchronised with standard ISI, we suggest that this area is the major cortical generator of the temporal CNV reflecting an automatic, action-independent mechanism underlying temporal expectancy.

  5. Ultra high spatial and temporal resolution breast imaging at 7T

    NARCIS (Netherlands)

    Bank, B.L. van de; Voogt, I.J.; Italiaander, M.; Stehouwer, B.L.; Boer, V.O.; Luijten, P.R.; Klomp, D.W.J.

    2013-01-01

    There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast-Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra-high spatial

  6. Spreading pattern of contrast medium in the high thoracic epidural space in rabbits: the effect of neck flexion and extension.

    Science.gov (United States)

    Kim, Mi-Hyun; Lim, Young Jin; Hong, Deok-Man; Jeon, Yun-Seok; Park, Hee Pyoung; Jeon, Young-Tae; Shin, Soon Young; Han, Sun Sook

    2010-08-01

    Neck flexion has been shown to increase cranial spread of contrast agent when a small fixed volume was injected into the high thoracic epidural space. The purpose of this study was to evaluate the effect of volume of contrast medium on its distribution through the high thoracic epidural space during neck extension and flexion using the rabbit model. An epidural catheter was introduced into the epidural space of New Zealand white rabbits with the tip located at the T3-4 intervertebral level. The neck was extended or flexed (n = 8 for each group), and the contrast medium was injected with the volume increasing by increments of 0.1 ml/kg, up to 0.3 ml/kg. The spread of contrast medium was determined by counting the number of vertebral body units using lateral epidurographic images. In both groups, the total spread of contrast medium was similar, increasing continuously with injected volume. The cranial spread was greater in the flexion group than the extension group. However, the caudal spread was greater in the extension than in the flexion group. In the extension group, the contrast medium spread caudally about twice as far as it spread cranially, but there was no statistically significant difference between cranial and caudal spread in the flexion group. In the high thoracic epidural space of rabbit, the contrast medium of varying doses showed limited cranial spread. The flexion of the neck increased cranial spread and extension of the neck increased caudal spread.

  7. High Spatiotemporal Resolution Dynamic Contrast-Enhanced MR Enterography in Crohn Disease Terminal Ileitis Using Continuous Golden-Angle Radial Sampling, Compressed Sensing, and Parallel Imaging.

    Science.gov (United States)

    Ream, Justin M; Doshi, Ankur; Lala, Shailee V; Kim, Sooah; Rusinek, Henry; Chandarana, Hersh

    2015-06-01

    The purpose of this article was to assess the feasibility of golden-angle radial acquisition with compress sensing reconstruction (Golden-angle RAdial Sparse Parallel [GRASP]) for acquiring high temporal resolution data for pharmacokinetic modeling while maintaining high image quality in patients with Crohn disease terminal ileitis. Fourteen patients with biopsy-proven Crohn terminal ileitis were scanned using both contrast-enhanced GRASP and Cartesian breath-hold (volume-interpolated breath-hold examination [VIBE]) acquisitions. GRASP data were reconstructed with 2.4-second temporal resolution and fitted to the generalized kinetic model using an individualized arterial input function to derive the volume transfer coefficient (K(trans)) and interstitial volume (v(e)). Reconstructions, including data from the entire GRASP acquisition and Cartesian VIBE acquisitions, were rated for image quality, artifact, and detection of typical Crohn ileitis features. Inflamed loops of ileum had significantly higher K(trans) (3.36 ± 2.49 vs 0.86 ± 0.49 min(-1), p < 0.005) and v(e) (0.53 ± 0.15 vs 0.20 ± 0.11, p < 0.005) compared with normal bowel loops. There were no significant differences between GRASP and Cartesian VIBE for overall image quality (p = 0.180) or detection of Crohn ileitis features, although streak artifact was worse with the GRASP acquisition (p = 0.001). High temporal resolution data for pharmacokinetic modeling and high spatial resolution data for morphologic image analysis can be achieved in the same acquisition using GRASP.

  8. Temporal and spatial multiplexed infrared single-photon counter based on high-speed avalanche photodiode.

    Science.gov (United States)

    Chen, Xiuliang; Ding, Chengjie; Pan, Haifeng; Huang, Kun; Laurat, Julien; Wu, Guang; Wu, E

    2017-03-15

    We report on a high-speed temporal and spatial multiplexed single-photon counter with photon-number-resolving capability up to four photons. The infrared detector combines a fiber loop to split, delay and recombine optical pulses and a 200 MHz dual-channel single-photon detector based on InGaAs/InP avalanche photodiode. To fully characterize the photon-number-resolving capability, we perform quantum detector tomography and then reconstruct its positive-operator-valued measure and the associated Wigner functions. The result shows that, despite of the afterpulsing noise and limited system detection efficiency, this temporal and spatial multiplexed single-photon counter can already find applications for large repetition rate quantum information schemes.

  9. High seed dispersal ability of Pinus canariensis in stands of contrasting density inferred from genotypic data

    Directory of Open Access Journals (Sweden)

    Unai López de Heredia

    2015-04-01

    Full Text Available Aim of the study: Models that combine parentage analysis from molecular data with spatial information of seeds and seedlings provide a framework to describe and identify the factors involved in seed dispersal and recruitment of forest species. In the present study we used a spatially explicit method (the gene shadow model in order to assess primary and effective dispersal in Pinus canariensis. Area of study: Pinus canariensis is endemic to the Canary Islands (Spain. Sampling sites were a high density forest in southern slopes of Tenerife and a low density stand in South Gran Canaria. Materials and methods: We fitted models based on parentage analysis from seeds and seedlings collected in two sites with contrasting stand density, and then compared the resulting dispersal distributions. Main results: The results showed that: 1 P. canariensis has a remarkable dispersal ability compared to other pine species; 2 there is no discordance between primary and effective dispersals, suggesting limited secondary dispersal by animals and lack of Janzen-Connell effect; and 3 low stand densities enhance the extent of seed dispersal, which was higher in the low density stand. Research highlights: The efficient dispersal mechanism of P. canariensis by wind inferred by the gene shadow model is congruent with indirect measures of gene flow, and has utility in reconstructing past demographic events and in predicting future distribution ranges for the species.

  10. Complete sparing of high-contrast color input to motion perception in cortical color blindness.

    Science.gov (United States)

    Cavanagh, P; Hénaff, M A; Michel, F; Landis, T; Troscianko, T; Intriligator, J

    1998-07-01

    It is widely held that color and motion are processed by separate parallel pathways in the visual system, but this view is difficult to reconcile with the fact that motion can be detected in equiluminant stimuli that are defined by color alone. To examine the relationship between color and motion, we tested three patients who had lost their color vision following cortical damage (central achromatopsia). Despite their profound loss in the subjective experience of color and their inability to detect the motion of faint colors, all three subjects showed surprisingly strong responses to high-contrast, moving color stimuli--equal in all respects to the performance of subjects with normal color vision. The pathway from opponent-color detectors in the retina to the motion analysis areas must therefore be independent of the damaged color centers in the occipitotemporal area. It is probably also independent of the motion analysis area MT/V5, because the contribution of color to motion detection in these patients is much stronger than the color response of monkey area MT.

  11. Heterogeneously integrated long-wavelength VCSEL using silicon high contrast grating on an SOI substrate.

    Science.gov (United States)

    Ferrara, James; Yang, Weijian; Zhu, Li; Qiao, Pengfei; Chang-Hasnain, Connie J

    2015-02-09

    We report an electrically pumped hybrid cavity AlGaInAs-silicon long-wavelength VCSEL using a high contrast grating (HCG) reflector on a silicon-on-insulator (SOI) substrate. The VCSEL operates at silicon transparent wavelengths ~1.57 μm with >1 mW CW power outcoupled from the semiconductor DBR, and single-mode operation up to 65 °C. The thermal resistance of our device is measured to be 1.46 K/mW. We demonstrate >2.5 GHz 3-dB direct modulation bandwidth, and show error-free transmission over 2.5 km single mode fiber under 5 Gb/s direct modulation. We show a theoretical design of SOI-HCG serving both as a VCSEL reflector as well as waveguide coupler for an in-plane SOI waveguide, facilitating integration of VCSEL with in-plane silicon photonic circuits. The novel HCG-VCSEL design, which employs scalable flip-chip eutectic bonding, may enable low cost light sources for integrated optical links.

  12. Multiscale finite element methods for high-contrast problems using local spectral basis functions

    KAUST Repository

    Efendiev, Yalchin

    2011-02-01

    In this paper we study multiscale finite element methods (MsFEMs) using spectral multiscale basis functions that are designed for high-contrast problems. Multiscale basis functions are constructed using eigenvectors of a carefully selected local spectral problem. This local spectral problem strongly depends on the choice of initial partition of unity functions. The resulting space enriches the initial multiscale space using eigenvectors of local spectral problem. The eigenvectors corresponding to small, asymptotically vanishing, eigenvalues detect important features of the solutions that are not captured by initial multiscale basis functions. Multiscale basis functions are constructed such that they span these eigenfunctions that correspond to small, asymptotically vanishing, eigenvalues. We present a convergence study that shows that the convergence rate (in energy norm) is proportional to (H/Λ*)1/2, where Λ* is proportional to the minimum of the eigenvalues that the corresponding eigenvectors are not included in the coarse space. Thus, we would like to reach to a larger eigenvalue with a smaller coarse space. This is accomplished with a careful choice of initial multiscale basis functions and the setup of the eigenvalue problems. Numerical results are presented to back-up our theoretical results and to show higher accuracy of MsFEMs with spectral multiscale basis functions. We also present a hierarchical construction of the eigenvectors that provides CPU savings. © 2010.

  13. Comparison of two hemofiltration protocols for prevention of contrast-induced nephropathy in high-risk patients.

    Science.gov (United States)

    Marenzi, Giancarlo; Lauri, Gianfranco; Campodonico, Jeness; Marana, Ivana; Assanelli, Emilio; De Metrio, Monica; Grazi, Marco; Veglia, Fabrizio; Fabbiocchi, Franco; Montorsi, Piero; Bartorelli, Antonio L

    2006-02-01

    Contrast-induced nephropathy is a complication of contrast medium administration during diagnostic and interventional procedures, with important prognostic relevance. Patients with chronic kidney disease have a higher risk for contrast-induced nephropathy and poorer outcome. In patients with chronic kidney disease, hemofiltration reduces contrast-induced nephropathy incidence and improves long-term survival. We assessed the mechanisms involved in the prophylactic effect of hemofiltration and of the most effective hemofiltration protocol to prevent contrast-induced nephropathy in patients with chronic kidney disease. We randomized 92 patients with chronic kidney disease (creatinine clearance 25% increase in creatinine) and the in-hospital clinical course were compared in the three groups. Twelve patients (40%) in the control group, 8 patients (26%) in the post-hemofiltration group, and 1 patient (3%) in the pre/post-hemofiltration group experienced contrast-induced nephropathy (P = .0013); hemodialysis was required in 9 (30%), three (10%), and zero (0%) patients, respectively (P = .002). In-hospital mortality was 20%, 10%, and 0%, respectively (P = .03). Hemofiltration is an effective strategy for contrast-induced nephropathy prevention in patients with chronic kidney disease who are undergoing cardiovascular procedures. Pre-hemofiltration is required to obtain the full clinical benefit, suggesting that, among different mechanisms possibly involved, high-volume controlled hydration before contrast media exposure plays a major role.

  14. Suppression of high-density artefacts in x-ray CT images using temporal digital subtraction with application to cryotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Baissalov, R.; Sandison, G.A.; Rewcastle, J.C. [Department of Medical Physics, Tom Baker Cancer Center, Calgary, Canada, T2N 4N2 2 Department of Physics and Astronomy, University of Calgary, Calgary T2N 2N4 (Canada); Donnelly, B.J. [Department of Surgery, Tom Baker Cancer Center, Calgary, Canada, T2N 4N2 4 Department of Surgery, Foothills Hospital, Calgary T2N 2T7 (Canada); Saliken, J.C. [Department of Surgery, Tom Baker Cancer Center, Calgary T2N 4N2 (Canada); Department of Diagnostic Imaging, Foothills Hospital, Calgary T2N 2T7 (Canada); McKinnon, J.G. [Department of Surgery, Foothills Hospital, Calgary T2N 2T7 (Canada); Muldrew, K. [Department of Surgery, Faculty of Medicine, University of Calgary, Calgary T2N 2T7 (Canada)

    2000-05-01

    Image guidance in cryotherapy is usually performed using ultrasound. Although not currently in routine clinical use, x-ray CT imaging is an alternative means of guidance that can display the full 3D structure of the iceball, including frozen and unfrozen regions. However, the quality of x-ray CT images is compromised by the presence of high-density streak artefacts. To suppress these artefacts we applied temporal digital subtraction (TDS). This TDS method has the added advantage of improving the grey-scale contrast between frozen and unfrozen tissue in the CT images. Two sets of CT images were taken of a phantom material, cryoprobes and a urethral warmer (UW) before and during the cryoprobe freeze cycle. The high-density artefacts persisted in both image sets. TDS was performed on these two image sets using the corresponding mask image of unfrozen material and the same geometrical configuration of the cryoprobes and the UW. The resultant difference image had a significantly reduced artefact content. Thus TDS can be used to significantly suppress or eliminate high-density CT streak artefacts without reducing the metallic content of the cryoprobes. In vivo study needs to be conducted to establish the utility of this TDS procedure for CT assisted prostate or liver cryotherapy. Applying TDS in x-ray CT guided cryotherapy will facilitate estimation of the number and location of all frozen and unfrozen regions, potentially making cryotherapy safer and less operator dependent. (author)

  15. Spatiotemporal specificity of contrast adaptation in mouse primary visual cortex

    Directory of Open Access Journals (Sweden)

    Emily Elizabeth LeDue

    2013-10-01

    Full Text Available Prolonged viewing of high contrast gratings alters perceived stimulus contrast, and produces characteristic changes in the contrast response functions of neurons in the primary visual cortex (V1. This is referred to as contrast adaptation. Although contrast adaptation has been well studied, its underlying neural mechanisms are not well understood. Therefore, we investigated contrast adaptation in mouse V1 with the goal of establishing a quantitative description of this phenomenon in a genetically manipulable animal model. One interesting aspect of contrast adaptation that has been observed both perceptually and in single unit studies is its specificity for the spatial and temporal characteristics of the stimulus. Therefore in the present work we determined if the magnitude of contrast adaptation in mouse V1 neurons was dependent on the spatial frequency and temporal frequency of the adapting grating. We used protocols that were readily comparable with previous studies in cats and primates, and also a novel contrast ramp stimulus that characterized the spatial and temporal specificity of contrast adaptation simultaneously. Similar to previous work in higher mammals, we found that contrast adaptation was strongest when the spatial frequency and temporal frequency of the adapting grating matched the test stimulus. This suggests similar mechanisms underlying contrast adaptation across animal models and indicates that the rapidly advancing genetic tools available in mice could be used to provide insights into this phenomenon.

  16. Multilevel markov chain monte carlo method for high-contrast single-phase flow problems

    KAUST Repository

    Efendiev, Yalchin R.

    2014-12-19

    In this paper we propose a general framework for the uncertainty quantification of quantities of interest for high-contrast single-phase flow problems. It is based on the generalized multiscale finite element method (GMsFEM) and multilevel Monte Carlo (MLMC) methods. The former provides a hierarchy of approximations of different resolution, whereas the latter gives an efficient way to estimate quantities of interest using samples on different levels. The number of basis functions in the online GMsFEM stage can be varied to determine the solution resolution and the computational cost, and to efficiently generate samples at different levels. In particular, it is cheap to generate samples on coarse grids but with low resolution, and it is expensive to generate samples on fine grids with high accuracy. By suitably choosing the number of samples at different levels, one can leverage the expensive computation in larger fine-grid spaces toward smaller coarse-grid spaces, while retaining the accuracy of the final Monte Carlo estimate. Further, we describe a multilevel Markov chain Monte Carlo method, which sequentially screens the proposal with different levels of approximations and reduces the number of evaluations required on fine grids, while combining the samples at different levels to arrive at an accurate estimate. The framework seamlessly integrates the multiscale features of the GMsFEM with the multilevel feature of the MLMC methods following the work in [26], and our numerical experiments illustrate its efficiency and accuracy in comparison with standard Monte Carlo estimates. © Global Science Press Limited 2015.

  17. Zernike phase contrast in high-energy x-ray transmission microscopy based on refractive optics.

    Science.gov (United States)

    Falch, Ken Vidar; Lyubomirsky, Mikhail; Casari, Daniele; Snigirev, Anatoly; Snigireva, Irina; Detlefs, Carsten; Michiel, Marco Di; Lyatun, Ivan; Mathiesen, Ragnvald H

    2018-01-01

    The current work represents the first implementation of Zernike phase contrast for compound refractive lens based x-ray microscopy, and also the first successful Zernike phase contrast experiment at photon energies above 12 keV. Phase contrast was achieved by fitting a compound refractive lens with a circular phase plate. The resolution is demonstrated to be sub-micron, and can be improved using already existing technology. The possibility of combining the technique with polychromatic radiation is considered, and a preliminary test experiment was performed with positive results. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Discrete nanomolecular polyhedral borane scaffold supporting multiple gadolinium(III) complexes as a high performance MRI contrast agent.

    Science.gov (United States)

    Goswami, Lalit N; Ma, Lixin; Chakravarty, Shatadru; Cai, Quanyu; Jalisatgi, Satish S; Hawthorne, M Frederick

    2013-02-18

    An icosahedral closo-B(12)(2-) scaffold supports 12 copies of Gd(3+)-chelate held in close proximity with each other by suitable linkers which employ azide-alkyne click chemistry. This design is the first member of a new class of polyfunctional MRI contrast agents carrying a high payload of Gd(3+)-chelate in a sterically constrained configuration. The resulting contrast agent shows higher relaxivity values at high magnetic fields. MRI contrast agents currently in use are not as effective in this regard, presumably due to a lack of steric constraint of gadolinium centers and lower water exchange rates. In vivo MRI studies in mice show excellent contrast enhancement even at one-seventh of the safe clinical dose (0.04 mmol Gd/kg) for up to a 1 h exposure.

  19. Topology Optimization Using Multiscale Finite Element Method for High-Contrast Media

    DEFF Research Database (Denmark)

    Lazarov, Boyan Stefanov

    2014-01-01

    . The approach is relatively easy for parallelization, due to the complete independence of the subproblems, and ensures contrast independent convergence of the iterative state problem solvers. Several modifications for reducing the computational cost in connection to topology optimization are discussed...

  20. Low-Cost Ultra-High Spatial and Temporal Resolution Mapping of Intertidal Rock Platforms

    Science.gov (United States)

    Bryson, M.; Johnson-Roberson, M.; Murphy, R.

    2012-07-01

    Intertidal ecosystems have primarily been studied using field-based sampling; remote sensing offers the ability to collect data over large areas in a snapshot of time which could compliment field-based sampling methods by extrapolating them into the wider spatial and temporal context. Conventional remote sensing tools (such as satellite and aircraft imaging) provide data at relatively course, sub-meter resolutions or with limited temporal resolutions and relatively high costs for small-scale environmental science and ecology studies. In this paper, we describe a low-cost, kite-based imaging system and photogrammetric pipeline that was developed for constructing highresolution, 3D, photo-realistic terrain models of intertidal rocky shores. The processing pipeline uses automatic image feature detection and matching, structure-from-motion and photo-textured terrain surface reconstruction algorithms that require minimal human input and only a small number of ground control points and allow the use of cheap, consumer-grade digital cameras. The resulting maps combine colour and topographic information at sub-centimeter resolutions over an area of approximately 100m, thus enabling spatial properties of the intertidal environment to be determined across a hierarchy of spatial scales. Results of the system are presented for an intertidal rock platform at Cape Banks, Sydney, Australia. Potential uses of this technique include mapping of plant (micro- and macro-algae) and animal (e.g. gastropods) assemblages at multiple spatial and temporal scales.

  1. Failure Prognosis of High Voltage Circuit Breakers with Temporal Latent Dirichlet Allocation

    Directory of Open Access Journals (Sweden)

    Gaoyang Li

    2017-11-01

    Full Text Available The continual accumulation of power grid failure logs provides a valuable but rarely used source for data mining. Sequential analysis, aiming at exploiting the temporal evolution and exploring the future trend in power grid failures, is an increasingly promising alternative for predictive scheduling and decision-making. In this paper, a temporal Latent Dirichlet Allocation (TLDA framework is proposed to proactively reduce the cardinality of the event categories and estimate the future failure distributions by automatically uncovering the hidden patterns. The aim was to model the failure sequence as a mixture of several failure patterns, each of which was characterized by an infinite mixture of failures with certain probabilities. This state space dependency was captured by a hierarchical Bayesian framework. The model was temporally extended by establishing the long-term dependency with new co-occurrence patterns. Evaluation of the high voltage circuit breakers (HVCBs demonstrated that the TLDA model had higher fidelities of 51.13%, 73.86%, and 92.93% in the Top-1, Top-5, and Top-10 failure prediction tasks over the baselines, respectively. In addition to the quantitative results, we showed that the TLDA can be successfully used for extracting the time-varying failure patterns and capture the failure association with a cluster coalition method.

  2. Tracking channel bed resiliency in forested mountain catchments using high temporal resolution channel bed movement

    Science.gov (United States)

    Martin, Sarah E.; Conklin, Martha H.

    2018-01-01

    This study uses continuous-recording load cell pressure sensors in four, high-elevation (1500-1800 m), Sierra Nevada headwater streams to collect high-temporal-resolution, bedload-movement data for investigating the channel bed movement patterns within these streams for water years 2012-2014. Data show an annual pattern where channel bed material in the thalweg starts to build up in early fall, peaks around peak snow melt, and scours back to baseline levels during hydrograph drawdown and base flow. This pattern is punctuated by disturbance and recovery of channel bed material associated with short-term storm events. A conceptual model, linking sediment sources at the channel margins to patterns of channel bed fill and scour in the thalweg, is proposed building on the results of Martin et al. (2014). The material in the thalweg represents a balance between sediment supply from the channel margins and sporadic, conveyor-belt-like downstream transport in the thalweg. The conceptual model highlights not only the importance of production and transport rates but also that seasonal connectedness between the margins and thalweg is a key sediment control, determining the accumulation rate of sediment stores at the margins and the redistribution of sediment from margins to thalweg that feeds the conveyor belt. Disturbance and recovery cycles are observed at multiple temporal scales; but long term, the channel beds are stable, suggesting that the beds act as short-term storage for sediment but are in equilibrium interannually. The feasibility of use for these sensors in forested mountain stream environments is tested. Despite a high failure rate (50%), load cell pressure sensors show potential for high-temporal-resolution bedload measurements, allowing for the collection of channel bed movement data to move beyond time-integrated change measurements - where many of the subtleties of bedload movement patterns may be missed - to continuous and/or real-time measurements. This

  3. Evaluation of fast highly undersampled contrast-enhanced MR angiography (sparse CE-MRA) in intracranial applications - initial study

    Energy Technology Data Exchange (ETDEWEB)

    Gratz, Marcel; Quick, Harald H. [University of Duisburg-Essen, Erwin L. Hahn Institute for MR Imaging, Essen (Germany); University Hospital Essen, High Field and Hybrid MR Imaging, Essen (Germany); Schlamann, Marc [University Hospital Giessen and Marburg GmbH, Neuroradiology, Giessen (Germany); University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Goericke, Sophia [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Maderwald, Stefan [University of Duisburg-Essen, Erwin L. Hahn Institute for MR Imaging, Essen (Germany)

    2017-03-15

    To assess the image quality of sparsely sampled contrast-enhanced MR angiography (sparse CE-MRA) providing high spatial resolution and whole-head coverage. Twenty-three patients scheduled for contrast-enhanced MR imaging of the head, (N = 19 with intracranial pathologies, N = 9 with vascular diseases), were included. Sparse CE-MRA at 3 Tesla was conducted using a single dose of contrast agent. Two neuroradiologists independently evaluated the data regarding vascular visibility and diagnostic value of overall 24 parameters and vascular segments on a 5-point ordinary scale (5 = very good, 1 = insufficient vascular visibility). Contrast bolus timing and the resulting arterio-venous overlap was also evaluated. Where available (N = 9), sparse CE-MRA was compared to intracranial Time-of-Flight MRA. The overall rating across all patients for sparse CE-MRA was 3.50 ± 1.07. Direct influence of the contrast bolus timing on the resulting image quality was observed. Overall mean vascular visibility and image quality across different features was rated good to intermediate (3.56 ± 0.95). The average performance of intracranial Time-of-Flight was rated 3.84 ± 0.87 across all patients and 3.54 ± 0.62 across all features. Sparse CE-MRA provides high-quality 3D MRA with high spatial resolution and whole-head coverage within short acquisition time. Accurate contrast bolus timing is mandatory. (orig.)

  4. The effect of laser contrast on generation of highly charged Fe ions by ultra-intense femtosecond laser pulses

    Science.gov (United States)

    Faenov, Anatoly Ya.; Alkhimova, Maria A.; Pikuz, Tatiana A.; Skobelev, Igor Yu.; Nishiuchi, Mamiko; Sakaki, Hironao; Pirozhkov, Alexander S.; Sagisaka, Akito; Dover, Nicholas P.; Kondo, Kotaro; Ogura, Koichi; Fukuda, Yuji; Kiriyama, Hiromitsu; Andreev, Alexander; Nishitani, Keita; Miyahara, Takumi; Watanabe, Yukinobu; Pikuz, Sergey A.; Kando, Masaki; Kodama, Ruosuke; Kondo, Kiminori

    2017-07-01

    Experimental studies on the formation of highly charged ions of medium-Z elements using femtosecond laser pulses with different contrast levels were carried out. Multiply charged Fe ions were generated by laser pulses with 35 fs duration and an intensity exceeding 1021 W/cm2. Using high-resolution X-ray spectroscopic methods, bulk electron temperature of the generated plasma has been identified. It is shown that the presence of a laser pre-pulse at a contrast level of 105-106 with respect to the main pulse drastically decreases the degree of Fe ionization. We conclude that an effective source of energetic, multiply charged moderate and high- Z ions based on femtosecond laser-plasma interactions can be created only using laser pulses of ultra-high contrast.

  5. Nomarski serial time-encoded amplified microscopy for high-speed contrast-enhanced imaging of transparent media.

    Science.gov (United States)

    Fard, Ali M; Mahjoubfar, Ata; Goda, Keisuke; Gossett, Daniel R; Di Carlo, Dino; Jalali, Bahram

    2011-12-01

    High-speed high-contrast imaging modalities that enable image acquisition of transparent media without the need for chemical staining are essential tools for a broad range of applications; from semiconductor process monitoring to blood screening. Here we introduce a method for contrast-enhanced imaging of unstained transparent objects that is capable of high-throughput imaging. This method combines the Nomarski phase contrast capability with the ultrahigh frame rate and shutter speed of serial time-encoded amplified microscopy. As a proof of concept, we show imaging of a transparent test structure and white blood cells in flow at a shutter speed of 33 ps and a frame rate of 36.1 MHz using a single-pixel photo-detector. This method is expected to be a valuable tool for high-throughput screening of unstained cells.

  6. Postharvest water relations in cut rose cultivars with contrasting sensivity to high relative air humidity during growth

    NARCIS (Netherlands)

    Fanourakis, D.; Carvalho, S.M.P.; Almeida, D.P.F.; Kooten, van O.; Doorn, van der T.; Heuvelink, E.

    2012-01-01

    A constant high relative air humidity (RH) during cultivation can strongly reduce the vase life in some cut rose cultivars. We studied three contrasting cultivars in their tolerance to high RH in order to analyse in detail the water relations during postharvest and better understand this genotypic

  7. Guideline adherence for identification and hydration of high-risk hospital patients for contrast-induced nephropathy.

    NARCIS (Netherlands)

    Schilp, J.; Blok, C. de; Langelaan, M.; Spreeuwenberg, P.; Wagner, C.

    2014-01-01

    Background: Contrast-induced nephropathy (CIN) is a common cause of acute renal failure in hospital patients. To prevent CIN, identification and hydration of high-risk patients is important. Prevention of CIN by hydration of high-risk patients was one of the themes to be implemented in the Dutch

  8. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B [UT MD Anderson Cancer Center, Houston, TX (United States); Wang, K; Bayram, E [GE Healthcare Technologies, Waukesha, Wisconsin (United States)

    2016-06-15

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  9. A Stable Marching on-in-time Scheme for Solving the Time Domain Electric Field Volume Integral Equation on High-contrast Scatterers

    KAUST Repository

    Sayed, Sadeed Bin

    2015-05-05

    A time domain electric field volume integral equation (TD-EFVIE) solver is proposed for characterizing transient electromagnetic wave interactions on high-contrast dielectric scatterers. The TD-EFVIE is discretized using the Schaubert- Wilton-Glisson (SWG) and approximate prolate spherical wave (APSW) functions in space and time, respectively. The resulting system of equations can not be solved by a straightforward application of the marching on-in-time (MOT) scheme since the two-sided APSW interpolation functions require the knowledge of unknown “future” field samples during time marching. Causality of the MOT scheme is restored using an extrapolation technique that predicts the future samples from known “past” ones. Unlike the extrapolation techniques developed for MOT schemes that are used in solving time domain surface integral equations, this scheme trains the extrapolation coefficients using samples of exponentials with exponents on the complex frequency plane. This increases the stability of the MOT-TD-EFVIE solver significantly, since the temporal behavior of decaying and oscillating electromagnetic modes induced inside the scatterers is very accurately taken into account by this new extrapolation scheme. Numerical results demonstrate that the proposed MOT solver maintains its stability even when applied to analyzing wave interactions on high-contrast scatterers.

  10. The Effect of Spatial and Temporal Resolution of Cine Phase Contrast MRI on Wall Shear Stress and Oscillatory Shear Index Assessment

    NARCIS (Netherlands)

    Cibis, Merih; Potters, Wouter V.; Gijsen, Frank J.; Marquering, Henk; van Ooij, Pim; VanBavel, Ed; Wentzel, Jolanda J.; Nederveen, Aart J.

    2016-01-01

    Introduction Wall shear stress (WSS) and oscillatory shear index (OSI) are associated with atherosclerotic disease. Both parameters are derived from blood velocities, which can be measured with phase-contrast MRI (PC-MRI). Limitations in spatiotemporal resolution of PC-MRI are known to affect these

  11. Contrasting the Chromosomal Organization of Repetitive DNAs in Two Gryllidae Crickets with Highly Divergent Karyotypes.

    Directory of Open Access Journals (Sweden)

    Octavio M Palacios-Gimenez

    Full Text Available A large percentage of eukaryotic genomes consist of repetitive DNA that plays an important role in the organization, size and evolution. In the case of crickets, chromosomal variability has been found using classical cytogenetics, but almost no information concerning the organization of their repetitive DNAs is available. To better understand the chromosomal organization and diversification of repetitive DNAs in crickets, we studied the chromosomes of two Gryllidae species with highly divergent karyotypes, i.e., 2n(♂ = 29,X0 (Gryllus assimilis and 2n = 9, neo-X1X2Y (Eneoptera surinamensis. The analyses were performed using classical cytogenetic techniques, repetitive DNA mapping and genome-size estimation. Conserved characteristics were observed, such as the occurrence of a small number of clusters of rDNAs and U snDNAs, in contrast to the multiple clusters/dispersal of the H3 histone genes. The positions of U2 snDNA and 18S rDNA are also conserved, being intermingled within the largest autosome. The distribution and base-pair composition of the heterochromatin and repetitive DNA pools of these organisms differed, suggesting reorganization. Although the microsatellite arrays had a similar distribution pattern, being dispersed along entire chromosomes, as has been observed in some grasshopper species, a band-like pattern was also observed in the E. surinamensis chromosomes, putatively due to their amplification and clustering. In addition to these differences, the genome of E. surinamensis is approximately 2.5 times larger than that of G. assimilis, which we hypothesize is due to the amplification of repetitive DNAs. Finally, we discuss the possible involvement of repetitive DNAs in the differentiation of the neo-sex chromosomes of E. surinamensis, as has been reported in other eukaryotic groups. This study provided an opportunity to explore the evolutionary dynamics of repetitive DNAs in two non-model species and will contribute to the

  12. Effect of In-plane Mirror Dispersion on Vertical Cavities Based on High-Contrast Grating Mirrors

    DEFF Research Database (Denmark)

    Taghizadeh, Alireza; Mørk, Jesper; Chung, Il-Sug

    2015-01-01

    We report how the in-plane dispersion of a high-index-contrast grating reflector influences the transverse mode properties such as shorter wavelengths for lower-order transverse modes and different transverse-mode wavelength spacings for modes with the same size.......We report how the in-plane dispersion of a high-index-contrast grating reflector influences the transverse mode properties such as shorter wavelengths for lower-order transverse modes and different transverse-mode wavelength spacings for modes with the same size....

  13. Stratified premedication strategy for the prevention of contrast media hypersensitivity in high-risk patients.

    Science.gov (United States)

    Lee, Suh-Young; Yang, Min Suk; Choi, Young-Hoon; Park, Chang Min; Park, Heung-Woo; Cho, Sang Heon; Kang, Hye-Ryun

    2017-03-01

    Although the severity of hypersensitivity reactions to iodinated contrast media varies, it is well correlated with the severity of recurrent reactions; however, prophylaxis protocols are not severity-stratified. To assess the outcomes of tailored prophylaxis according to the severity of hypersensitivity reactions to iodinated contrast media. Our premedication protocols were stratified based on the severity of previous reactions: (1) 4 mg of chlorpheniramine for mild reactions, (2) adding 40 mg of methylprednisolone for moderate reactions, and (3) adding multiple doses of 40 mg of methylprednisolone for severe index reactions. Cases of reexposure in patients with a history of hypersensitivity reactions were routinely monitored and mandatorily recorded. Among a total of 850 patients who underwent enhanced computed tomography after severity-tailored prophylaxis, breakthrough reactions occurred in 17.1%, but most breakthrough reactions (89.0%) were mild and did not require medical treatment. Additional corticosteroid use did not reduce the breakthrough reaction rate in cases with a mild index reaction (16.8% vs 17.2%, P = .70). However, underpremedication with a single dose of corticosteroid revealed significantly higher rates of breakthrough reaction than did double doses of corticosteroid in cases with a severe index reaction (55.6% vs 17.4%, P = .02). Changing the iodinated contrast media resulted in an additional reduction of the breakthrough reaction rate overall (14.9% vs 32.1%, P = .001). In a total severity-based stratified prophylaxis regimens and changing iodinated contrast media can be considered in patients with a history of previous hypersensitivity reaction to iodinated contrast media to reduce the risk of breakthrough reactions. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  14. Coupling temporal and spatial gradient information in high-density unstructured Lagrangian measurements

    Science.gov (United States)

    Wong, Jaime G.; Rosi, Giuseppe A.; Rouhi, Amirreza; Rival, David E.

    2017-10-01

    Particle tracking velocimetry (PTV) produces high-quality temporal information that is often neglected when computing spatial gradients. A method is presented here to utilize this temporal information in order to improve the estimation of spatial gradients for spatially unstructured Lagrangian data sets. Starting with an initial guess, this method penalizes any gradient estimate where the substantial derivative of vorticity along a pathline is not equal to the local vortex stretching/tilting. Furthermore, given an initial guess, this method can proceed on an individual pathline without any further reference to neighbouring pathlines. The equivalence of the substantial derivative and vortex stretching/tilting is based on the vorticity transport equation, where viscous diffusion is neglected. By minimizing the residual of the vorticity-transport equation, the proposed method is first tested to reduce error and noise on a synthetic Taylor-Green vortex field dissipating in time. Furthermore, when the proposed method is applied to high-density experimental data collected with `Shake-the-Box' PTV, noise within the spatial gradients is significantly reduced. In the particular test case investigated here of an accelerating circular plate captured during a single run, the method acts to delineate the shear layer and vortex core, as well as resolve the Kelvin-Helmholtz instabilities, which were previously unidentifiable without the use of ensemble averaging. The proposed method shows promise for improving PTV measurements that require robust spatial gradients while retaining the unstructured Lagrangian perspective.

  15. Trends of labile trace metals in tropical urban water under highly contrasted weather conditions.

    Science.gov (United States)

    Villanueva, J D; Le Coustumer, P; Denis, A; Abuyan, R; Huneau, F; Motelica-Heino, M; Peyraube, N; Celle-Jeanton, H; Perez, T R; Espaldon, M V O

    2015-09-01

    The spatio-temporal trend of trace metals (Cd, Co, Cr, Cu, Ni, Pb, and Zn) in a tropical urban estuary under the influence of monsoon was determined using diffusive gradient in thin films (DGT) in situ samplers. Three different climatic periods were observed: period 1, dry with dredging activity; period 2, intermediate meaning from dry to wet event; and period 3, wet having continuous rainfall. Conforming to monsoon regimes, these periods correspond to the following: transition from winter to summer, winter, and summer monsoons, respectively. The distinction of each period is defined by their specific hydrological and physico-chemical conditions. Substantial concentrations of the trace metals were detected. The distribution and trend of the trace metals under the challenge of a tropical climate were able to follow using DGT as a sensitive in situ sampler. In order to identify the differences among periods, statistical analyses were performed. This allowed discriminating period 2 (oxic water) as significantly different compared to other periods. The spatio-temporal analysis was then applied in order to distinguish the trend of the trace metals. Results showed that the trend of trace metals can be described according to their response to (i) seasonal variations (Cd and Cr), (ii) spatio-temporal conditions (Co, Cu, Ni, and Pb), and (iii) neither (i) nor (ii) meaning exhibiting no response or having constant change (Zn). The correlation of the trace metals and the physico-chemical parameters reveals that Cd, Co, Cu, and Cr are proportional to the dissolved oxygen (DO), Cd and Ni are correlated pH, and Zn lightly influenced by salinity.

  16. High-contrast reflectance imaging of composite restorations color-matched to tooth structure at 1000-2300-nm

    Science.gov (United States)

    Fried, William A.; Simon, Jacob C.; Darling, Cynthia L.; Le, Oanh; Fried, Daniel

    2017-02-01

    A major advantage of composite restoration materials is that they can be color matched to the tooth. However, this presents a challenge when composites fail and they need to be replaced. Dentists typically spend more time repairing and replacing composites than placing new restorations. We have shown in previous studies that high-contrast images of composite can be acquired in occlusal transmission mode at near-IR wavelengths coincident with higher water absorption. The purpose of this study was to determine if similar high-contrast images can be acquired in reflectance mode at longer wavelengths where water absorption is even higher. Extracted human teeth with existing composite restoration (n=14) were imaged at wavelengths from 900-2300 using an extended range InGaAs camera. Our results indicate that NIR wavelengths longer than 1400-nm coincident with higher water absorption yield the highest contrast between dental composites and tooth structure in reflectance.

  17. Pair-Wise, Deformable Mirror, Image Plane-Based Diversity Electric Field Estimation for High Contrast Coronagraphy

    Science.gov (United States)

    Give'on, Amir; Kern, Brian D.; Shaklan, Stuart

    2011-01-01

    In this paper we describe the complex electric field reconstruction from image plane intensity measurements for high contrast coronagraphic imaging. A deformable mirror (DM) surface is modied with pairs of complementary shapes to create diversity in the image plane of the science camera where the intensity of the light is measured. Along with the Electric Field Conjugation correction algorithm, this estimation method has been used in various high contrast imaging testbeds to achieve the best contrasts to date both in narrow and in broad band light. We present the basic methodology of estimation in easy to follow list of steps, present results from HCIT and raise several open quations we are confronted with using this method.

  18. Capturing temporal variation in phosphorus dynamics in groundwater dominated rivers using automated high-frequency sampling

    Science.gov (United States)

    Bieroza, M. Z.; Heathwaite, A. L.; Mullinger, N. J.; Keenan, P. O.

    2012-04-01

    High-frequency river water quality monitoring provides detailed hydrochemical information on the time scale of hydrologic response. Several studies (Kirchner et al., 2004; Johnes, 2007; Cassidy and Jordan, 2011) have shown previously that coarse sampling approaches fail to quantify nutrient and sediment loads and to capture the fine structure of water quality dynamics correctly. A robust analysis of high-frequency nutrient and water quality time series can present a complex conceptual, analytical and computational problem. High-frequency nutrient monitoring provides new evidence of processes and patterns that could not be observed previously using standard coarse resolution sampling schemes. However, to fully utilise the wealth of information contained in high-frequency nutrient data, we need to address the following questions: how to detect complex coupling patterns and processes in high-resolution flow-nutrients data, how do these patterns and processes change throughout the period of observation, and how to distinguish noise signals from an evidence of real processes (Harris and Heathwaite, 2005). Here, hourly measurements of total phosphorus (TP), soluble reactive phosphorus (SRP) and turbidity were carried out using bank side analysers to study the biogeochemical response of a 54 km2 catchment of the River Leith, a tributary of the River Eden (Cumbria, UK). A remote automated mobile lab facilitates real-time high-frequency nutrient and water quality monitoring, with no time delay between collection and analysis of the reactive elements. The objectives of this study were two-fold: first to investigate the intrinsic complexity of the temporal relationship between phosphorus fractions (SRP, TP), turbidity and continuous hydrometric time series and secondly to investigate the possibilities of missing high-frequency phosphorus data infilling using continuous hydrometric time series. Complex non-linear relationships between flow, TP and SRP, turbidity were observed

  19. Anti-biofouling conducting polymer nanoparticles as a label-free optical contrast agent for high resolution subsurface biomedical imaging.

    Science.gov (United States)

    Au, Kin Man; Lu, Zenghai; Matcher, Stephen J; Armes, Steven P

    2013-11-01

    Optical coherence tomography (OCT) is a modern high resolution subsurface medical imaging technique. Herein we describe: (i) the synthesis of a thiophene-functionalized oligo(ethylene glycol) methacrylate (OEGMA)-based statistical copolymer, denoted poly(2TMOI-OEGMA); (ii) the preparation of sterically-stabilized polypyrrole (PPy) nanoparticles of approximately 60 nm diameter; (iii) the evaluation of these nanoparticles as a NIR-absorbing optical contrast agent for high-resolution OCT imaging. We show that poly(2TMOI-OEGMA)-stabilized PPy nanoparticles exhibit similar optical properties to poly(vinyl alcohol) (PVA)-stabilized PPy nanoparticles of comparable size prepared using commercially available PVA. Spectroscopic measurements and Mie calculations indicate that both types of PPy nanoparticles strongly absorb NIR radiation above 1000 nm, suggesting their potential use as OCT contrast agents. In vitro OCT studies indicate that both types of PPy nanoparticles reduce NIR backscattering within homogeneous intralipid tissue phantoms, offering almost identical contrast performance in this medium. However, PVA-stabilized PPy nanoparticles became colloidally unstable when dispersed in physiological buffer and immersed in a solid biotissue phantom and hence failed to generate a strong contrast effect. In contrast, the poly(2TMOI-OEGMA)-stabilized PPy nanoparticles remained well-dispersed and hence exhibited a strong rapid onset contrast effect within the biotissue phantom under identical physiological conditions. Ex vivo studies performed on excised chicken and porcine skin tissue demonstrated that topical administration of a low concentration of poly(2TMOI-OEGMA)-stabilized PPy nanoparticles rapidly enhances OCT image contrast in both cases, allowing key tissue features to be readily identified. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. [Prevention of contrast-induced nephropathy and management of high-risk patients].

    Science.gov (United States)

    Marenzi, Giancarlo

    2009-02-01

    Radiological procedures that utilize intravascular iodinated contrast media are being widely applied for both diagnostic and therapeutic purposes and represent one of the main causes of contrast-induced nephropathy (CIN) and hospital-acquired renal failure. Owing to the lack of any effective treatment, prevention of this iatrogenic disease, which is associated with significant in-hospital and long-term morbidity and mortality and increased costs, is the key strategy. However, prevention of CIN continues to elude clinicians and is a main concern during percutaneous coronary interventions, as patients undergoing these procedures often have multiple comorbidities. The purpose of this article is to examine the risk factors and clinical course of CIN, as well as the most recent studies dealing with its prevention and potential therapeutic interventions, especially during percutaneous coronary interventions.

  1. Electrochromic device of PEDOT-PANI hybrid system for fast response and high optical contrast

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Joo-Hee; Oh, Yeon-Ji; Hwang, Seong-Ju; Choy, Jin-Ho [Center for Intelligent Nano-Bio Materials (CINBM), Department of Chemistry and Nano Sciences, Ewha Womans University, Seoul 120-750 (Korea); Paek, Seung-Min [Center for Intelligent Nano-Bio Materials (CINBM), Department of Chemistry and Nano Sciences, Ewha Womans University, Seoul 120-750 (Korea); Beamline Research Division, Pohang Accelerator Laboratory, Pohang 790-784 (Korea)

    2009-12-15

    An organic-organic hybrid system composed of the polyaniline (PANI) and poly-(3,4-ethylenedioxythiophene) (PEDOT) with controlled thickness was developed successfully in order to realize synergetic effects in electrochromic (EC) properties such as optical contrast and color-switching rate. From the UV transmittance spectra, we found that the optical contrast ({delta}%T) was enhanced up to 6-72% at the wavelength of 580 nm compared with the previous PANI-PEDOT ECDs. Furthermore, the optimized ECD showed an extremely fast response time of less than 160 ms. It is therefore concluded that such a complementary full.cell system of PEDOT-PANI ECD is applicable as an optical device. (author)

  2. Determination of Destructed and Infracted Forest Areas with Multi-temporal High Resolution Satellite Images

    Science.gov (United States)

    Seker, D. Z.; Unal, A.; Kaya, S.; Alganci, U.

    2015-12-01

    Migration from rural areas to city centers and their surroundings is an important problem of not only our country but also the countries that under development stage. This uncontrolled and huge amount of migration brings out urbanization and socio - economic problems. The demand on settling the industrial areas and commercial activities nearby the city centers results with a negative change in natural land cover on cities. Negative impacts of human induced activities on natural resources and land cover has been continuously increasing for decades. The main human activities that resulted with destruction and infraction of forest areas can be defined as mining activities, agricultural activities, industrial / commercial activities and urbanization. Temporal monitoring of the changes in spatial distribution of forest areas is significantly important for effective management and planning progress. Changes can occur as spatially large destructions or small infractions. Therefore there is a need for reliable, fast and accurate data sources. At this point, satellite images proved to be a good data source for determination of the land use /cover changes with their capability of monitoring large areas with reasonable temporal resolutions. Spectral information derived from images provides discrimination of land use/cover types from each other. Developments in remote sensing technology in the last decade improved the spatial resolution of satellites and high resolution images were started to be used to detect even small changes in the land surface. As being the megacity of Turkey, Istanbul has been facing a huge migration for the last 20 years and effects of urbanization and other human based activities over forest areas are significant. Main focus of this study is to determine the destructions and infractions in forest areas of Istanbul, Turkey with 2.5m resolution SPOT 5 multi-temporal satellite imagery. Analysis was mainly constructed on threshold based classification of

  3. Fat suppression techniques for obtaining high resolution dynamic contrast enhanced bilateral breast MR images at 7T

    NARCIS (Netherlands)

    van der Velden, Tijl A; Schmitz, Alexander M Th; Gilhuijs, Kenneth G A; Veldhuis, Wouter B; Luijten, Peter R; Boer, Vincent O; Klomp, DWJ

    2016-01-01

    OBJECTIVES: To compare water selective excitation (WSE) and Dixon fat suppression in the context of high-resolution dynamic contrast enhanced MRI of the breast at 7T. METHODS: Ten healthy volunteers and one patient with a malignant breast lesion were scanned at 7T. The MRI protocol contained 3D

  4. High contrast pet imaging of GRPR expression in prostate cancer using cobalt-labeled bombesin antagonist RM26

    DEFF Research Database (Denmark)

    Mitran, Bogdan; Thisgaard, Helge; Rosenström, Ulrika

    2017-01-01

    ) and 1000 (24 h pi).The favorable biodistribution of cobalt-labeled NOTA-PEG2-RM26 translated into high contrast preclinical PET/CT (using55Co) and SPECT/CT (using57Co) images of PC-3 xenografts.The initial biological results suggest that55Co-NOTA-PEG2-RM26 is a promising tracer for PET visualization...

  5. Anisotropic photoconductivity and current deflection induced in Bi12SiO20 by high contrast interference pattern

    DEFF Research Database (Denmark)

    Kukhtarev, N.V.; Lyuksyutov, S; Buchhave, Preben

    1996-01-01

    We have predicted and observed an anisotropic photocurrent induced in the cubic crystal Bi/sub 12/SiO/sub 20/ by a high-contrast interference pattern. The transverse current detected when the interference pattern is tilted is caused by deflection of the direct current generated by an external...

  6. 80-nm-tunable high-index-contrast subwavelength grating long-wavelength VCSEL: Proposal and numerical simulations

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Mørk, Jesper; Sirbu, Alexei

    2010-01-01

    A widely-tunable single-mode long wavelength vertical-cavity surface-emitting laser structure employing a MEMStunable high-index-contrast subwavelength grating (HCG) is suggested and numerically investigated. A very large 80- nm linear tuning range was obtained as the HCG was actuated by -220 to ...

  7. Fat suppression techniques for obtaining high resolution dynamic contrast enhanced bilateral breast MR images at 7 tesla

    DEFF Research Database (Denmark)

    van der Velden, Tijl A; Schmitz, Alexander M Th; Gilhuijs, Kenneth G A

    2016-01-01

    OBJECTIVES: To compare water selective excitation (WSE) and Dixon fat suppression in the context of high-resolution dynamic contrast enhanced MRI of the breast at 7 tesla. METHODS: Ten healthy volunteers and one patient with a malignant breast lesion were scanned at 7 tesla. The MRI protocol...

  8. Right hemispheric contributions to fine auditory temporal discriminations: high-density electrical mapping of the duration mismatch negativity (MMN

    Directory of Open Access Journals (Sweden)

    Pierfilippo De Sanctis

    2009-04-01

    Full Text Available That language processing is primarily a function of the left hemisphere has led to the supposition that auditory temporal discrimination is particularly well-tuned in the left hemisphere, since speech discrimination is thought to rely heavily on the registration of temporal transitions. However, physiological data have not consistently supported this view. Rather, functional imaging studies often show equally strong, if not stronger, contributions from the right hemisphere during temporal processing tasks, suggesting a more complex underlying neural substrate. The mismatch negativity (MMN component of the human auditory evoked-potential (AEP provides a sensitive metric of duration processing in human auditory cortex and lateralization of MMN can be readily assayed when sufficiently dense electrode arrays are employed. Here, the sensitivity of the left and right auditory cortex for temporal processing was measured by recording the MMN to small duration deviants presented to either the left or right ear. We found that duration deviants differing by just 15% (i.e. rare 115 ms tones presented in a stream of 100 ms tones elicited a significant MMN for tones presented to the left ear (biasing the right hemisphere. However, deviants presented to the right ear elicited no detectable MMN for this separation. Further, participants detected significantly more duration deviants and committed fewer false alarms for tones presented to the left ear during a subsequent psychophysical testing session. In contrast to the prevalent model, these results point to equivalent if not greater right hemisphere contributions to temporal processing of small duration changes.

  9. High-speed spatial frequency domain imaging with temporally modulated light

    Science.gov (United States)

    Applegate, Matthew B.; Roblyer, Darren

    2017-07-01

    Spatial frequency domain imaging (SFDI) is a wide-field diffuse optical technique used to obtain optical properties and chromophore concentrations in highly scattering media, such as biological tissue. Here, we present a method for rapidly acquiring multispectral SFDI data by modulating each illumination wavelength at a different temporal frequency. In the remitted signal, each wavelength is temporally demodulated and processed using conventional SFDI techniques. We demonstrate a proof-of-concept system capable of acquiring wide-field maps (2048×1536 pixels, 8.5×6.4 cm) of optical properties at three wavelengths in under 2.5 s. Data acquired by this method show a good agreement with a commercial SFDI imaging system (with an average error of 13% in absorption and 8% in scattering). Additionally, we show that this strategy is insensitive to ambient lighting conditions, making it more practical for clinical translation. In the future, this technique could be expanded to tens or hundreds of wavelengths without increasing acquisition time.

  10. Efficient temporal and interlayer parameter prediction for weighted prediction in scalable high efficiency video coding

    Science.gov (United States)

    Tsang, Sik-Ho; Chan, Yui-Lam; Siu, Wan-Chi

    2017-01-01

    Weighted prediction (WP) is an efficient video coding tool that was introduced since the establishment of the H.264/AVC video coding standard, for compensating the temporal illumination change in motion estimation and compensation. WP parameters, including a multiplicative weight and an additive offset for each reference frame, are required to be estimated and transmitted to the decoder by slice header. These parameters cause extra bits in the coded video bitstream. High efficiency video coding (HEVC) provides WP parameter prediction to reduce the overhead. Therefore, WP parameter prediction is crucial to research works or applications, which are related to WP. Prior art has been suggested to further improve the WP parameter prediction by implicit prediction of image characteristics and derivation of parameters. By exploiting both temporal and interlayer redundancies, we propose three WP parameter prediction algorithms, enhanced implicit WP parameter, enhanced direct WP parameter derivation, and interlayer WP parameter, to further improve the coding efficiency of HEVC. Results show that our proposed algorithms can achieve up to 5.83% and 5.23% bitrate reduction compared to the conventional scalable HEVC in the base layer for SNR scalability and 2× spatial scalability, respectively.

  11. Highly enhanced and temporally stable field emission from MWCNTs grown on aluminum coated silicon substrate

    Directory of Open Access Journals (Sweden)

    M. Sreekanth

    2015-06-01

    Full Text Available In this work, a detailed field emission study of multi-walled carbon nanotubes (MWCNTs grown on Si and Al coated Si substrates is reported. Morphological and microstructural studies of the films show higher entanglement of CNTs in the case of CNT/Si film as compared to CNT/Al/Si film. Raman studies show that the defect mediated peak (D is substantially suppressed as compared to graphitic peak (G resulting in significant reduction in ID/IG value in CNT/Al/Si film. Field emission (FE current density of CNT/Al/Si film (∼25 mA/cm2 is significantly higher as compared to that of CNT/Si film (∼1.6 mA/cm2. A substantial improvement in temporal stability is also observed in CNT/Al/Si film. This enhancement in field emission current is attributed to strong adhesion between substrate and CNTs, low work function, high local field enhancement factor at the CNT tips and less entanglement of CNTs grown on Al/Si. The temporally stable CNT/Al/Si cold cathode can be a potential candidate to replace conventional electron sources in prototype devices.

  12. Plant tissues in 3D via X-ray tomography: simple contrasting methods allow high resolution imaging.

    Directory of Open Access Journals (Sweden)

    Yannick M Staedler

    Full Text Available Computed tomography remains strongly underused in plant sciences despite its high potential in delivering detailed 3D phenotypical information because of the low X-ray absorption of most plant tissues. Existing protocols to study soft tissues display poor performance, especially when compared to those used on animals. More efficient protocols to study plant material are therefore needed. Flowers of Arabidopsis thaliana and Marcgravia caudata were immersed in a selection of contrasting agents used to treat samples for transmission electron microscopy. Grayscale values for floral tissues and background were measured as a function of time. Contrast was quantified via a contrast index. The thick buds of Marcgravia were scanned to determine which contrasting agents best penetrate thick tissues. The highest contrast increase with cytoplasm-rich tissues was obtained with phosphotungstate, whereas osmium tetroxide and bismuth tatrate displayed the highest contrast increase with vacuolated tissues. Phosphotungstate also displayed the best sample penetration. Furthermore, infiltration with phosphotungstate allowed imaging of all plants parts at a high resolution of 3 µm, which approaches the maximum resolution of our equipment: 1.5 µm. The high affinity of phosphotungstate for vasculature, cytoplasm-rich tissue, and pollen causes these tissues to absorb more X-rays than the surrounding tissues, which, in turn, makes these tissues appear brighter on the scan data. Tissues with different brightness can then be virtually dissected from each other by selecting the bracket of grayscale to be visualized. Promising directions for the future include in silico phenotyping and developmental studies of plant inner parts (e.g., ovules, vasculature, pollen, and cell nuclei via virtual dissection as well as correlations of quantitative phenotypes with omics datasets. Therefore, this work represents a crucial improvement of previous methods, allowing new directions of

  13. Plant tissues in 3D via X-ray tomography: simple contrasting methods allow high resolution imaging.

    Science.gov (United States)

    Staedler, Yannick M; Masson, David; Schönenberger, Jürg

    2013-01-01

    Computed tomography remains strongly underused in plant sciences despite its high potential in delivering detailed 3D phenotypical information because of the low X-ray absorption of most plant tissues. Existing protocols to study soft tissues display poor performance, especially when compared to those used on animals. More efficient protocols to study plant material are therefore needed. Flowers of Arabidopsis thaliana and Marcgravia caudata were immersed in a selection of contrasting agents used to treat samples for transmission electron microscopy. Grayscale values for floral tissues and background were measured as a function of time. Contrast was quantified via a contrast index. The thick buds of Marcgravia were scanned to determine which contrasting agents best penetrate thick tissues. The highest contrast increase with cytoplasm-rich tissues was obtained with phosphotungstate, whereas osmium tetroxide and bismuth tatrate displayed the highest contrast increase with vacuolated tissues. Phosphotungstate also displayed the best sample penetration. Furthermore, infiltration with phosphotungstate allowed imaging of all plants parts at a high resolution of 3 µm, which approaches the maximum resolution of our equipment: 1.5 µm. The high affinity of phosphotungstate for vasculature, cytoplasm-rich tissue, and pollen causes these tissues to absorb more X-rays than the surrounding tissues, which, in turn, makes these tissues appear brighter on the scan data. Tissues with different brightness can then be virtually dissected from each other by selecting the bracket of grayscale to be visualized. Promising directions for the future include in silico phenotyping and developmental studies of plant inner parts (e.g., ovules, vasculature, pollen, and cell nuclei) via virtual dissection as well as correlations of quantitative phenotypes with omics datasets. Therefore, this work represents a crucial improvement of previous methods, allowing new directions of research to be

  14. High gamma oscillations in medial temporal lobe during overt production of speech and gestures.

    Directory of Open Access Journals (Sweden)

    Lars Marstaller

    Full Text Available The study of the production of co-speech gestures (CSGs, i.e., meaningful hand movements that often accompany speech during everyday discourse, provides an important opportunity to investigate the integration of language, action, and memory because of the semantic overlap between gesture movements and speech content. Behavioral studies of CSGs and speech suggest that they have a common base in memory and predict that overt production of both speech and CSGs would be preceded by neural activity related to memory processes. However, to date the neural correlates and timing of CSG production are still largely unknown. In the current study, we addressed these questions with magnetoencephalography and a semantic association paradigm in which participants overtly produced speech or gesture responses that were either meaningfully related to a stimulus or not. Using spectral and beamforming analyses to investigate the neural activity preceding the responses, we found a desynchronization in the beta band (15-25 Hz, which originated 900 ms prior to the onset of speech and was localized to motor and somatosensory regions in the cortex and cerebellum, as well as right inferior frontal gyrus. Beta desynchronization is often seen as an indicator of motor processing and thus reflects motor activity related to the hand movements that gestures add to speech. Furthermore, our results show oscillations in the high gamma band (50-90 Hz, which originated 400 ms prior to speech onset and were localized to the left medial temporal lobe. High gamma oscillations have previously been found to be involved in memory processes and we thus interpret them to be related to contextual association of semantic information in memory. The results of our study show that high gamma oscillations in medial temporal cortex play an important role in the binding of information in human memory during speech and CSG production.

  15. High contrast periodic plasma pattern formation during the laser-induced breakdown in transparent dielectric

    Science.gov (United States)

    Gildenburg, V. B.; Pavlichenko, I. A.

    2017-12-01

    Based on a simple 1D initial-time model, we have carried out the numerical simulation for the spatio-temporal evolution of femtosecond laser pulse induced breakdown in transparent dielectric (fused silica) at the nonlinear stage of the plasma resonance ionization instability. The instability develops from very small seed perturbations of the medium permittivity and results in, because of the strong mutual enhancement of the electric field and plasma density perturbations in the plasma resonance region, the formation of the subwavelength periodic plasma-field structure consisting of the overcritical plasma layers perpendicular to the laser polarization. The calculation of the time-course and spatial profiles of the plasma density, field amplitude, and energy deposition density in the medium during one breakdown pulse has allowed us to establish the main possible scenarios of the process considered and to found the laser intensity range where this process can underlie the nanograting modification of the medium by repeated pulses.

  16. Translation of a High-Level Temporal Model into Lower Level Models: Impact of Modelling at Different Description Levels

    DEFF Research Database (Denmark)

    Kraft, Peter; Sørensen, Jens Otto

    2001-01-01

    The paper attempts theoretically to clarify the interrelation between various levels of descriptions used in the modelling and the programming of information systems. We suggest an analysis where we characterise the description levels with respect to how precisely they may handle information about...... given types of properties, and examine how descriptions on higher levels translate into descriptions on lower levels. Our example looks at temporal properties where the information is concerned with the existence in time. In a high level temporal model with information kept in a three-dimensional space...... the existences in time can be mapped precisely and consistently securing a consistent handling of the temporal properties. We translate the high level temporal model into an entity-relationship model, with the information in a two-dimensional graph, and finally we look at the translations into relational...

  17. The Impact of Horizontal and Temporal Resolution on Convection and Precipitation with High-Resolution GEOS-5

    Science.gov (United States)

    Putman, William P.

    2012-01-01

    Using a high-resolution non-hydrostatic version of GEOS-5 with the cubed-sphere finite-volume dynamical core, the impact of spatial and temporal resolution on cloud properties will be evaluated. There are indications from examining convective cluster development in high resolution GEOS-5 forecasts that the temporal resolution within the model may playas significant a role as horizontal resolution. Comparing modeled convective cloud clusters versus satellite observations of brightness temperature, we have found that improved. temporal resolution in GEOS-S accounts for a significant portion of the improvements in the statistical distribution of convective cloud clusters. Using satellite simulators in GEOS-S we will compare the cloud optical properties of GEOS-S at various spatial and temporal resolutions with those observed from MODIS. The potential impact of these results on tropical cyclone formation and intensity will be examined as well.

  18. High spatial resolution magnetic resonance imaging of experimental cerebral venous thrombosis with a blood pool contrast agent.

    Science.gov (United States)

    Spuentrup, E; Wiethoff, A J; Parsons, E C; Spangenberg, P; Stracke, C P

    2010-06-01

    The purpose of this study was to investigate the feasibility of clot visualization in small sinus and cortical veins with contrast enhanced MRA in a cerebral venous thrombosis animal model using a blood pool contrast agent, Gadofosveset, and high spatial resolution imaging. For induction of cerebral venous thrombosis a recently developed combined interventional and microsurgical model was used. Cerebral sinus and cortical vein thrombosis was induced in six pigs. Two further pigs died during the procedure. Standard structural, time-of-flight- and phase contrast-angiograms were followed by fast time resolved high resolution 3D MRA (4D MRA) and subsequent high spatial resolution 3D MRA in the equilibrium phase with and without addition of parallel imaging. Visualization of the clots using the different sequences was subjectively compared and contrast-to-noise ratio (CNR) was assessed. In the remaining six animals the procedure and MR-imaging protocol including administration of Gadofosveset was successfully completed. The 3D high resolution MRA in the equilibrium phase without the addition of parallel imaging was superior to all the other applied MR measurement techniques in terms of visualization of the clots. Only applying this sequence bridging vein thromboses were also seen as a small filling defect with a high CNR of >18. Only the non-accelerated high spatial resolution 3D MRA in the equilibrium in conjunction with the blood pool agent Gadofosveset allows for high-contrast visualization of very small clots in the cerebral sinus and cortical veins. STATEMENT CLINICAL IMPACT: Detection of cortical vein thrombosis is of high clinical impact. Conventional MRI sequences often fail to visualize the clot. We could demonstrate that, in contrast to conventional sequences, with high spatial resolution 3D MRA in the equilibrium in conjunction with the blood pool agent Gadofosveset very small clots in the cerebral sinus and cortical veins could be successfully visualized. We

  19. The influence of neck flexion and extension on the distribution of contrast medium in the high thoracic epidural space.

    Science.gov (United States)

    Lee, Chul Joong; Jeon, Yunseok; Lim, Young Jin; Bahk, Jae Hyon; Kim, Yong Chul; Lee, Sang Chul; Kim, Chong Sung

    2007-06-01

    For safe and effective thoracic epidural analgesia (TEA), it is important to control the level of TEA and to identify factors that influence its spread. In this study, we observed the distribution of contrast injected into the high thoracic epidural space during neck flexion and extension. An epidural catheter was inserted into the epidural space until its tip was located at the T1-2 intervertebral level. Patients were randomly allocated to three groups (extension, flexion, and neutral groups), and were injected with 5 mL of contrast when the neck was extended, flexed, or in the neutral position. Extent of contrast spread was determined by counting the number of vertebral body units (VBUs) through lateral epidurography. Forty-two patients were equally allocated to the three groups. Radiographic spreads in the cephalad direction (median) was 1.0, 5.5, and 1.5 VBUs in the extension, flexion, and neutral groups, and spread was greater in the flexion than in the other two groups (P flexion, and neutral groups, respectively, which was not significantly different among groups (P = 0.145). Cranial spread of contrast in the high thoracic epidural space is limited. However, neck flexion increases cranial spread. These results suggest that when TEA is high, the tip of the epidural catheter should be located at the upper part of the level to be blocked and that neck flexion may cause an unwanted cervical block.

  20. Direct comparison of high-temporal-resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice.

    Science.gov (United States)

    Roberts, Thomas A; Price, Anthony N; Jackson, Laurence H; Taylor, Valerie; David, Anna L; Lythgoe, Mark F; Stuckey, Daniel J

    2017-10-01

    Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one-dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high-temporal-resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user-independent technique. Here, we investigated the performance of high-temporal-resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in-house, high-temporal-resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom-made, open-source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high-frequency, pulsed-wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high-temporal-resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high-temporal-resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high-temporal-resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression. © 2017 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  1. Asymmetric-detection time-stretch optical microscopy (ATOM) for ultrafast high-contrast cellular imaging in flow

    Science.gov (United States)

    Wong, Terence T. W.; Lau, Andy K. S.; Ho, Kenneth K. Y.; Tang, Matthew Y. H.; Robles, Joseph D. F.; Wei, Xiaoming; Chan, Antony C. S.; Tang, Anson H. L.; Lam, Edmund Y.; Wong, Kenneth K. Y.; Chan, Godfrey C. F.; Shum, Ho Cheung; Tsia, Kevin K.

    2014-01-01

    Accelerating imaging speed in optical microscopy is often realized at the expense of image contrast, image resolution, and detection sensitivity – a common predicament for advancing high-speed and high-throughput cellular imaging. We here demonstrate a new imaging approach, called asymmetric-detection time-stretch optical microscopy (ATOM), which can deliver ultrafast label-free high-contrast flow imaging with well delineated cellular morphological resolution and in-line optical image amplification to overcome the compromised imaging sensitivity at high speed. We show that ATOM can separately reveal the enhanced phase-gradient and absorption contrast in microfluidic live-cell imaging at a flow speed as high as ~10 m/s, corresponding to an imaging throughput of ~100,000 cells/sec. ATOM could thus be the enabling platform to meet the pressing need for intercalating optical microscopy in cellular assay, e.g. imaging flow cytometry – permitting high-throughput access to the morphological information of the individual cells simultaneously with a multitude of parameters obtained in the standard assay. PMID:24413677

  2. Spatiotemporal neurodynamics underlying internally and externally driven temporal prediction: a high spatial resolution ERP study.

    Science.gov (United States)

    Mento, Giovanni; Tarantino, Vincenza; Vallesi, Antonino; Bisiacchi, Patrizia Silvia

    2015-03-01

    Temporal prediction (TP) is a flexible and dynamic cognitive ability. Depending on the internal or external nature of information exploited to generate TP, distinct cognitive and brain mechanisms are engaged with the same final goal of reducing uncertainty about the future. In this study, we investigated the specific brain mechanisms involved in internally and externally driven TP. To this end, we employed an experimental paradigm purposely designed to elicit and compare externally and internally driven TP and a combined approach based on the application of a distributed source reconstruction modeling on a high spatial resolution electrophysiological data array. Specific spatiotemporal ERP signatures were identified, with significant modulation of contingent negative variation and frontal late sustained positivity in external and internal TP contexts, respectively. These different electrophysiological patterns were supported by the engagement of distinct neural networks, including a left sensorimotor and a prefrontal circuit for externally and internally driven TP, respectively.

  3. Measuring Absolute RNA Copy Numbers at High Temporal Resolution Reveals Transcriptome Kinetics in Development

    Directory of Open Access Journals (Sweden)

    Nick D.L. Owens

    2016-01-01

    Full Text Available Transcript regulation is essential for cell function, and misregulation can lead to disease. Despite technologies to survey the transcriptome, we lack a comprehensive understanding of transcript kinetics, which limits quantitative biology. This is an acute challenge in embryonic development, where rapid changes in gene expression dictate cell fate decisions. By ultra-high-frequency sampling of Xenopus embryos and absolute normalization of sequence reads, we present smooth gene expression trajectories in absolute transcript numbers. During a developmental period approximating the first 8 weeks of human gestation, transcript kinetics vary by eight orders of magnitude. Ordering genes by expression dynamics, we find that “temporal synexpression” predicts common gene function. Remarkably, a single parameter, the characteristic timescale, can classify transcript kinetics globally and distinguish genes regulating development from those involved in cellular metabolism. Overall, our analysis provides unprecedented insight into the reorganization of maternal and embryonic transcripts and redefines our ability to perform quantitative biology.

  4. High contrast optical imaging methods for image guided laser ablation of dental caries lesions

    Science.gov (United States)

    LaMantia, Nicole R.; Tom, Henry; Chan, Kenneth H.; Simon, Jacob C.; Darling, Cynthia L.; Fried, Daniel

    2014-02-01

    Laser based methods are well suited for automation and can be used to selectively remove dental caries to minimize the loss of healthy tissues and render the underlying enamel more resistant to acid dissolution. The purpose of this study was to determine which imaging methods are best suited for image-guided ablation of natural non-cavitated carious lesions on occlusal surfaces. Multiple caries imaging methods were compared including near-IR and visible reflectance and quantitative light fluorescence (QLF). In order for image-guided laser ablation to be feasible, chemical and physical modification of tooth surfaces due to laser irradiation cannot greatly reduce the contrast between sound and demineralized dental hard tissues. Sound and demineralized surfaces of 48 extracted human molar teeth with non-cavitated lesions were examined. Images were acquired before and after laser irradiation using visible and near-IR reflectance and QLF at several wavelengths. Polarization sensitive-optical coherence tomography was used to confirm that lesions were present. The highest contrast was attained at 1460-nm and 1500-1700-nm, wavelengths coincident with higher water absorption. The reflectance did not decrease significantly after laser irradiation for those wavelengths.

  5. Patients at high risk of adverse events from intravenous contrast media after computed tomography examination

    Energy Technology Data Exchange (ETDEWEB)

    Reddan, Donal [University College Galway Hospitals, Unit 7, Merlin Park Hospital, Galway (Ireland)]. E-mail: donal.reddan@mailn.hse.ie

    2007-05-15

    Adverse reactions to iodinated contrast media (CM) may occur and require prompt recognition and treatment. Although adverse reactions to radiocontrast agents cannot be eliminated, an important first step toward reducing their incidence is to identify patients at greatest risk. Prior to examinations using CM, patients should be adequately assessed by obtaining thorough medical histories and using simple screening tests. Studies have demonstrated that patients with a history of asthma, allergy, hyperthyroidism, and previous reaction to CM are at risk for severe reactions to iodinated CM. Renal adverse reactions reportedly occur more frequently in patients with pre-existing chronic kidney disease, especially those with diabetic nephropathy. Patients with congestive heart failure, dehydration, older age, and those who use nephrotoxic medications are also at risk for developing contrast-associated nephropathy. The occurrence of adverse events may be further increased in patients with multiple risk factors. As the number of patients undergoing computed tomography procedures continues to increase, it is essential for physicians to be able to identify patients at risk for adverse events of CM. Patient-related risk factors are discussed and simple tools for risk stratification presented.

  6. Hybrid averaging offers high-flow contrast by cost apportionment among imaging time, axial, and lateral resolution in optical coherence tomography angiography.

    Science.gov (United States)

    Li, Peng; Cheng, Yuxuan; Li, Pei; Zhou, Liping; Ding, Zhihua; Ni, Yang; Pan, Cong

    2016-09-01

    The current temporal, wavelength, angular, and spatial averaging approaches trade imaging time and resolution for multiple independent measurements that improve the flow contrast in optical coherence tomography angiography (OCTA). We find that these averaging approaches are equivalent in principle, offering almost the same flow contrast enhancement as the number of averages increases. Based on this finding, we propose a hybrid averaging strategy for contrast enhancement by cost apportionment. We demonstrate that, compared with any individual approach, the hybrid averaging is able to offer a desired flow contrast without severe degradation of imaging time and resolution. Making use of the extended range of a VCSEL-based swept-source OCT, an angular averaging approach by path length encoding is also demonstrated for flow contrast enhancement.

  7. Spatial-temporal trends and risk of suicide in Central Brazil: an ecological study contrasting indigenous and non-indigenous populations.

    Science.gov (United States)

    Orellana, Jesem D; Balieiro, Antônio A; Fonseca, Fernanda R; Basta, Paulo C; Souza, Maximiliano L Ponte de

    2016-01-01

    To examine spatial-temporal distribution and risk of suicide, as well as trends in suicide mortality rates, in the indigenous and non-indigenous population of the state of Mato Grosso do Sul, Brazil. Data were obtained from the Information Department of the Brazilian Unified Health System. Deaths recorded as voluntary self-inflicted injuries (ICD-10 codes X60.0 to X84.9) were considered suicide. Suicide rates were estimated and adjusted by age in the population > 9 years of age. Kernel analysis was used to assess the spatial distribution of suicide cases, while trend analysis was carried out using a non-parametric test (Mann-Kendall). The suicide risk among the indigenous population was 8.1 (95%CI 7.2-9.0) times higher than in the non-indigenous population. For indigenous residents in the 15-24 age group, the risk was 18.5 (95%CI 17.5-19.6) times higher than in the non-indigenous population. The majority of indigenous cases were concentrated in a few villages in reservation areas, mainly occupied by Guarani-Kaiowá and Guarani-Ñandeva groups. Rate patterns remained stable over time in both groups. Suicide is a serious public health problem in Mato Grosso do Sul, and has had an alarming and disproportionate impact on the indigenous population for more than a decade.

  8. High resolution 3D MRI of mouse mammary glands with intra-ductal injection of contrast media.

    Science.gov (United States)

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Roman, Brian B; Jansen, Sanaz A; Macleod, Kay; Conzen, Suzanne D; Karczmar, Gregory S

    2015-01-01

    The purpose of this study was to use high resolution three-dimensional (3D) magnetic resonance imaging (MRI) to study mouse mammary gland ductal architecture based on intra-ductal injection of contrast agents. Female FVB/N mice age 12-20 weeks (n=12), were used in this study. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple. Approximately 20-25μL of a Gadodiamide/Trypan blue/saline solution was injected slowly over one minute into the nipple and duct. To prevent washout of contrast media from ducts due to perfusion, and maximize the conspicuity of ducts on MRI, mice were sacrificed one minute after injection. High resolution 3D T1-weighted images were acquired on a 9.4T Bruker scanner after sacrifice to eliminate motion artifacts and reduce contrast media leakage from ducts. Trypan blue staining was well distributed throughout the ductal tree. MRI showed the mammary gland ductal structure clearly. In spoiled gradient echo T1-weighted images, the signal-to-noise ratio of regions identified as enhancing mammary ducts following contrast injection was significantly higher than that of muscle (pcontrast media (pcontrast agents to measure metabolism or target receptors in normal ducts and ducts with in situ cancers. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Temporal Trends of Sources of Cigarettes among U.S. High School Students: 2001-2015.

    Science.gov (United States)

    Dai, Hongying; Hao, Jianqiang

    2018-01-12

    Restricting the supply of cigarettes to youth plays an important role in reducing youth smoking. The study included data from 8 years of the national Youth Risk Behavior Survey (YRBS) from 2001 to 2015 with 99,572 high school students less than 18 years old. Data were weighted to provide national estimates of the temporal trends of cigarette sources. Each cigarette source was analyzed by a separate multivariable logistic regression model and the linear trend odds ratio (aOR) was adjusted by age, sex, race/ethnicity, and smoking frequency. The current smoking prevalence among U.S. high school students less than 18 years of age declined from 26.9% in 2001 to 9.9% in 2015. Among current smokers, we found an overall downward trend of buying cigarettes in a store (aOR=0.98, CI [0.96 - 1.00]) and an overall upward trend of getting them "some other way" (aOR=1.03, CI [1.01 - 1.05]). The prevalence of purchasing cigarettes in a store significantly declined among smokers aged 16-17, male smokers, white smokers, and daily smokers, but not among other categories. The prevalence of getting cigarettes "some other way" significantly increased across all groups except Hispanic smokers and medium-level or daily smokers. The proportion of high school students reporting that they bought cigarettes from a store has been declining over the years, while the proportion of high schoolers reporting that they got cigarettes "some other way" has been increasing. The temporal trends also varied by age, sex, race/ethnicity, and smoking frequency. Patterns of high school student access to cigarettes have changed from 2001 to 2015, with access from "some other way" becoming more prevalent. The differences in cigarette acquisition by age, sex, race/ethnicity, and smoking frequency highlight the importance of implementing tailored policies and interventions to reduce youth access to cigarettes and prevent youth from smoking. This is not a clinical trial.

  10. High contrast ultrasonic imaging of resin-rich regions in graphite/epoxy composites using entropy

    Science.gov (United States)

    Hughes, Michael S.; McCarthy, John E.; Bruillard, Paul. J.; Marsh, Jon N.; Wickline, Samuel A.

    2016-02-01

    This study compares different approaches for imaging a near-surface resin-rich defect in a thin graphite/epoxy plate using backscattered ultrasound. The specimen was created by cutting a circular hole in the second ply; this region filled with excess resin from the graphite/epoxy sheets during the curing process. Backscat-tered waveforms were acquired using a 4 in. focal length, 5MHz center frequency broadband transducer, scanned on a 100 × 100 grid of points that were 0.03 × 0.03 in. apart. The specimen was scanned with the defect side closest to the transducer. Consequently, the reflection from the resin-rich region cannot be gated from the large front-wall echo. At each point in the grid 256 waveforms were averaged together and subsequently used to produce peak-to-peak, Signal Energy (sum of squared digitized waveform values), as well as entropy images of two different types (a Renyi entropy, and a joint entropy). As the figure shows, all of the entropy images exhibit better border delineation and defect contrast than the either the peak-to-peak or Signal Energy. The best results are obtained using the joint entropy of the backscattered waveforms with a reference function. Two different references are examined. The first is a reflection of the insonifying pulse from a stainless steel reflector. The second is an approximate optimum obtained from an iterative parametric search. The joint entropy images produced using this reference exhibit three times the contrast obtained in previous studies.

  11. High-gamma band fronto-temporal coherence as a measure of functional connectivity in speech motor control.

    Science.gov (United States)

    Kingyon, J; Behroozmand, R; Kelley, R; Oya, H; Kawasaki, H; Narayanan, N S; Greenlee, J D W

    2015-10-01

    The neural basis of human speech is unclear. Intracranial electrophysiological recordings have revealed that high-gamma band oscillations (70-150Hz) are observed in the frontal lobe during speech production and in the temporal lobe during speech perception. Here, we tested the hypothesis that the frontal and temporal brain regions had high-gamma coherence during speech. We recorded electrocorticography (ECoG) from the frontal and temporal cortices of five humans who underwent surgery for medically intractable epilepsy, and studied coherence between the frontal and temporal cortex during vocalization and playback of vocalization. We report two novel results. First, we observed high-gamma band as well as theta (4-8Hz) coherence between frontal and temporal lobes. Second, both high-gamma and theta coherence were stronger when subjects were actively vocalizing as compared to playback of the same vocalizations. These findings provide evidence that coupling between sensory-motor networks measured by high-gamma coherence plays a key role in feedback-based monitoring and control of vocal output for human vocalization. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  12. High-resolution temporal analysis of deep subseafloor microbial communities inhabiting basement fluids

    Science.gov (United States)

    Jungbluth, S.; Lin, H. T.; Hsieh, C. C.; Rappe, M. S.

    2014-12-01

    , demonstrating that high-quality borehole fluid samples may range up to ~45,000 cells x ml-1. This analysis helps to constrain subseafloor biomass estimates, reveals its variability in both short and long temporal scales, and provides a glimpse of the variability in microbial community structure that spans from hours to years.

  13. Anatomic distribution of gadolinium contrast medium by high-resolution magnetic resonance imaging after peribulbar and retrobulbar injections.

    Science.gov (United States)

    Almeida, David R P; Belliveau, Michel J; Enright, Thomas; Islam, Omar; El-Defrawy, Sherif R; Gale, Jeffrey

    2012-06-01

    To examine the anatomic distribution of gadolinium contrast medium by high-resolution surface-coil magnetic resonance imaging after peribulbar and retrobulbar injection. Comparative case series in which 4 healthy volunteers were randomized to peribulbar (n = 2) or retrobulbar (n = 2) injection of gadolinium and lidocaine hydrochloride, 2%, without epinephrine. Magnetic resonance imaging was performed before injection and at 5 minutes and 90 minutes after injection. The peribulbar injection technique resulted in contrast medium primarily in the extraconal space, with no gadolinium observed at the orbital apex; surprisingly, a small amount of contrast medium was observed in the pterygopalatine fossa immediately after peribulbar injection. The retrobulbar injection technique resulted in gadolinium signal diffusely enhancing the intraconal space, orbital apex, optic nerve sheath, and optic canal. The signal intensity was clearly observed in the cavernous sinus surrounding the cavernous portion of the internal carotid artery. A small amount of contrast medium was detected in the pterygopalatine fossa. The retrobulbar injection technique localizes to the intraconal space, with access to intracranial and central nervous system structures via the optic canal, superior orbital fissure, and cavernous sinus. In contrast, the peribulbar injection technique produces a mostly extraconal distribution; however, intraconal solution may communicate with the central nervous system via the inferior orbital fissure and pterygopalatine fossa. This novel finding suggests that peribulbar anesthesia has a readily accessible route for central nervous system toxic effects. Magnetic resonance imaging with gadolinium contrast medium administration provides an important methodological advantage over previously described techniques and is a safe, reproducible, and superior method of orbital imaging.

  14. Spatial and temporal evolution of ion energies in high power impulse magnetron sputtering plasma discharge

    Science.gov (United States)

    Hecimovic, A.; Ehiasarian, A. P.

    2010-09-01

    High power impulse magnetron sputtering (HIPIMS) is a novel deposition technology successfully implemented on full scale industrial machines. HIPIMS utilizes short pulses of high power delivered to the target in order to generate high amount of metal ions. The life-span of ions between the pulses and their energy distribution could strongly influence the properties and characteristics of the deposited coating. In modern industrial coating machines the sample rotates on a substrate holder and changes its position and distance with regard to the magnetron. Time resolved measurements of the ion energy distribution function (IEDF) at different distances from the magnetron have been performed to investigate the temporal evolution of ions at various distances from target. The measurements were performed using two pressures, 1 and 3 Pa to investigate the influence of working gas pressure on IEDF. Plasma sampling energy-resolved mass spectroscopy was used to measure the IEDF of Ti1+, Ti2+, Ar1+, and Ar2+ ions in HIPIMS plasma discharge with titanium (Ti) target in Ar atmosphere. The measurements were done over a full pulse period and the distance between the magnetron and the orifice of the mass spectrometer was changed from 25 to 215 mm.

  15. Scanning EM of non-heavy metal stained biosamples: Large-field of view, high contrast and highly efficient immunolabeling.

    Science.gov (United States)

    Kuipers, Jeroen; de Boer, Pascal; Giepmans, Ben N G

    2015-10-01

    Scanning electron microscopy (SEM) is increasing its application in life sciences for electron density measurements of ultrathin sections. These are traditionally analyzed with transmission electron microscopy (TEM); by most labs, SEM analysis still is associated with surface imaging only. Here we report several advantages of SEM for thin sections over TEM, both for structural inspection, as well as analyzing immuno-targeted labels such as quantum dots (QDs) and gold, where we find that QD-labeling is ten times more efficient than gold-labeling. Furthermore, we find that omitting post-staining with uranyl and lead leads to QDs readily detectable over the ultrastructure, but under these conditions ultrastructural contrast was even almost invisible in TEM examination. Importantly, imaging in SEM with STEM detection leads to both outstanding QDs and ultrastructural contrast. STEM imaging is superior over back-scattered electron imaging of these non-contrasted samples, whereas secondary electron detection cannot be used at all. We conclude that examination of ultrathin sections by SEM, which may be immunolabeled with QDs, will allow rapid and straightforward analysis of large fields with more efficient labeling than can be achieved with immunogold. The large fields of view routinely achieved with SEM, but not with TEM, allows straightforward raw data sharing using virtual microscopy, also known as nanotomy when this concerns EM data in the life sciences. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. "Pseudo washout" sign in high-flow hepatic hemangioma on gadoxetic acid contrast-enhanced MRI mimicking hypervascular tumor.

    Science.gov (United States)

    Doo, Kyung Won; Lee, Chang Hee; Choi, Jae Woong; Lee, Jongmee; Kim, Kyeong Ah; Park, Cheol Min

    2009-12-01

    The purpose of this article is to describe the "pseudo washout" sign of high-flow hepatic hemangioma that mimics hypervascular tumor on gadoxetic acid-enhanced MRI. High-flow hemangiomas might show relatively low signal intensity because of gadoxetic acid contrast uptake in the surrounding normal liver parenchyma during the equilibrium (3-minute delay) phase. Such findings are called pseudo washout and can mimic hypervascular hepatic tumors. However, high-flow hemangioma can be diagnosed by observing bright signal intensity on T2-weighted imaging, arterial phase-dominant enhancement, pseudo washout sign during the equilibrium phase, and isointense or slightly increased signal intensity on subtraction images.

  17. The influence of vegetation covers on soil moisture dynamics at high temporal resolution in scattered tree woodlands of Mediterranean climate

    Science.gov (United States)

    Lozano-Parra, Javier; Schnabel, Susanne; Ceballos-Barbancho, Antonio

    2015-04-01

    Soil water is a key factor that controls the organization and functioning of dryland ecosystems. However, in spite of its great importance in ecohydrological processes, most of the studies focus on daily or longer timescales, while its dynamics at shorter timescales are very little known. The main objective of this work was to determine the role of vegetation covers (grassland and tree canopy) in the soil hydrological response using measurements with high temporal resolution in evergreen oak woodland with Mediterranean climate. For this, soil water content was monitored continuously with a temporal resolution of 30 minutes and by means of capacitance sensors, mainly for the hydrological years 2010-2011 and 2011-2012. They were installed at 5, 10 and 15 cm, and 5 cm above the bedrock and depending on soil profile. This distribution along the soil profile is justified because soils are generally very shallow and most of the roots are concentrated in the upper layer. The sensors were gathered in 8 soil moisture stations in two contrasting situations characterized by different vegetation covers: under tree canopy and in open spaces or grasslands. Soil moisture variations were calculated at rainfall event scale at top soil layer and deepest depth by the difference between the final and initial soil moisture registered by a sensor at the finish and the beginning of the rainfall event, respectively. Besides, as soil moisture changes are strongly influenced by antecedent conditions, different antecedent soil moisture conditions or states, from driest to wettest, were also defined. The works were carried out in 3 experimental farms of the Spanish region of Extremadura. Results obtained revealed that rainwater amount bypassing vegetation covers and reaching the soil may temporarily be modified by covers according to precipitation properties and antecedent environmental conditions (from dry to wet) before the rain episode. Rainfall amounts triggering a positive soil

  18. The TRIDENT laser at LANL: New “dial-a-contrast” and high-contrast experimental capabilities

    Directory of Open Access Journals (Sweden)

    Flippo K.A.

    2013-11-01

    Full Text Available The Trident laser facility at Los Alamos National Laboratory (LANL has served for more than 20 years as an important tool in inertial confinement fusion (ICF and Material Dynamics research. An energy and power upgrade of the short-pulse beam line to 100J / 200 TW was made in 2007 and contrast improvements have been made continually since. The combination of this powerful new short-pulse beamline with the two flexible long pulse beamlines, and a total of three different target areas, makes Trident a highly flexible and versatile research tool for high energy density laboratory plasma (HEDLP research. The newest “Dial-a-Contrast” (DaC features are described, along with nominal performance of the laser at the presently available highest contrast.

  19. Plant Tissues in 3D via X-Ray Tomography: Simple Contrasting Methods Allow High Resolution Imaging

    OpenAIRE

    Yannick M Staedler; David Masson; Jürg Schönenberger

    2013-01-01

    Computed tomography remains strongly underused in plant sciences despite its high potential in delivering detailed 3D phenotypical information because of the low X-ray absorption of most plant tissues. Existing protocols to study soft tissues display poor performance, especially when compared to those used on animals. More efficient protocols to study plant material are therefore needed. Flowers of Arabidopsis thaliana and Marcgravia caudata were immersed in a selection of contrasting agents ...

  20. Photonic heterostructure High Contrast Grating as a novel polarization control and light confinement system in HCG VCSEL

    Science.gov (United States)

    Gebski, M.; Dems, M.; Chen, J.; Qijie, W.; Dao Hua, Z.; Czyszanowski, T.

    2014-05-01

    In this paper we present results of computer optical simulations of VCSEL with modified high refractive index contrast grating (HCG) as a top mirror. We consider the HCG of two different designs which determine the lateral aperture. Such HCG mirror provides selective guiding effect. We show that proper design of aperture of HCG results in almost sixfold increase in cavity Q-factor for zero order mode and a discrimination of higher order modes.

  1. Voiding urosonography including urethrosonography: high-quality examinations with an optimised procedure using a second-generation US contrast agent.

    Science.gov (United States)

    Duran, Carmina; del Riego, Javier; Riera, Luis; Martin, Cesar; Serrano, Carlos; Palaña, Pau

    2012-06-01

    Voiding urosonography (VUS) is established as a technique for detecting vesicoureteral reflux in children. To evaluate the quality of images of the entire urinary tract when using a second-generation US contrast agent and a modified VUS technique. We evaluated 307 VUS examinations performed using SonoVue® in 591 pelvi-ureter units in 295 children of mean age, 27.1 (S.D., 42.5) months, with 154 (50.2%) of the examinations performed in boys; 58 children also underwent VUS using Levovist®. Three criteria were used for quality assessment of the bladder image: (1) progressive incorporation of contrast material in the bladder, (2) homogeneous bladder-filling to maximum capacity, and (3) visualisation of the posterior bladder wall. Criterion 1 was fulfilled in 305 (99.3%), criterion 2 in 304 (99%) and criterion 3 in 304 (99%) studies. In children who underwent VUS with both contrast agents, the concordance between the two techniques was moderate for findings in the bladder (Cohen K = 0.487; P < 0001) and perfect for findings in the male urethra. By a modified technique we obtained high-quality images of the bladder with the second-generation contrast agent.

  2. A general tool for evaluating high-contrast coronagraphic telescope performance error budgets

    Science.gov (United States)

    Marchen, Luis F.; Shaklan, Stuart B.

    2009-08-01

    This paper describes a general purpose Coronagraph Performance Error Budget (CPEB) tool that we have developed under the NASA Exoplanet Exploration Program. The CPEB automates many of the key steps required to evaluate the scattered starlight contrast in the dark hole of a space-based coronagraph. It operates in 3 steps: first, a CodeV or Zemax prescription is converted into a MACOS optical prescription. Second, a Matlab program calls ray-trace code that generates linear beam-walk and aberration sensitivity matrices for motions of the optical elements and line-ofsight pointing, with and without controlled coarse and fine-steering mirrors. Third, the sensitivity matrices are imported by macros into Excel 2007 where the error budget is created. Once created, the user specifies the quality of each optic from a predefined set of PSDs. The spreadsheet creates a nominal set of thermal and jitter motions and combines them with the sensitivity matrices to generate an error budget for the system. The user can easily modify the motion allocations to perform trade studies.

  3. Dark-field hyperlens for high-contrast sub-wavelength imaging

    DEFF Research Database (Denmark)

    Repän, Taavi; Zhukovsky, Sergei; Lavrinenko, Andrei

    2016-01-01

    By now superresolution imaging using hyperbolic metamaterial (HMM) structures – hyperlenses – has been demonstrated both theoretically and experimentally. The hyperlens operation relies on the fact that HMM allows propagation of waves with very large transverse wavevectors, which would be evanesc......By now superresolution imaging using hyperbolic metamaterial (HMM) structures – hyperlenses – has been demonstrated both theoretically and experimentally. The hyperlens operation relies on the fact that HMM allows propagation of waves with very large transverse wavevectors, which would...... be evanescent in common isotropic media (thus giving rise to the diffraction limit). However, nearly all hyperlenses proposed so far have been suitable only for very strong scatterers – such as holes in a metal film. When weaker scatterers, dielectric objects for example, are imaged then incident light forms...... a very strong background, and weak scatterers are not visible due to a poor contrast. We propose a so-called dark-field hyperlens, which would be suitable for imaging of weakly scattering objects. By designing parameters of the HMM, we managed to obtain its response in such way that the hyperlens...

  4. A new emissive projection display technology and a high contrast DLP projection display on black screen

    Science.gov (United States)

    Sun, Ted X.; Cheng, Botao

    2011-03-01

    In this paper, Sun Innovations demonstrates an innovative emissive projection display (EPD) system. It is comprised of a fully transparent fluorescent screen with a UV image projector. The screen can be applied to glass windows or windshield, without affecting visible light transmission. The UV projector can be based on either a DLP (digital light processor) or a laser scanner display engine. For a DLP based projector, a discharge lamp coupled to a set of UV filters can be applied to generate a full color video image on the transparent screen. UV or blue-ray laser diodes of different wavelengths can be combined with scanning mirrors to generate a vector display for full windshield display applications. This display combines the best of both worlds of conventional projection and emissive display technologies. Like a projection display, the screen has no pixel structure and can be manufactured roll to roll; the display is scalable. Like an emissive display (e.g. plasma or CRT), the quality of the image is superior, with very large viewing angles. It also offers some unique features. For example, in addition to a fully transparent display on windows or windshields, it can be applied to a black substrate to create the first front projection display on true "black" screen that has superior image contrast at low projection power. This fundamentally new display platform can enable multiple major commercial applications that can not be addressed by any of the existing display technologies.

  5. A General Tool for Evaluating High-Contrast Coronagraphic Telescope Performance Error Budgets

    Science.gov (United States)

    Marchen, Luis F.; Shaklan, Stuart B.

    2009-01-01

    This paper describes a general purpose Coronagraph Performance Error Budget (CPEB) tool that we have developed under the NASA Exoplanet Exploration Program. The CPEB automates many of the key steps required to evaluate the scattered starlight contrast in the dark hole of a space-based coronagraph. It operates in 3 steps: first, a CodeV or Zemax prescription is converted into a MACOS optical prescription. Second, a Matlab program calls ray-trace code that generates linear beam-walk and aberration sensitivity matrices for motions of the optical elements and line-of-sight pointing, with and without controlled coarse and fine-steering mirrors. Third, the sensitivity matrices are imported by macros into Excel 2007 where the error budget is created. Once created, the user specifies the quality of each optic from a predefined set of PSDs. The spreadsheet creates a nominal set of thermal and jitter motions and combines them with the sensitivity matrices to generate an error budget for the system. The user can easily modify the motion allocations to perform trade studies.

  6. Hybrid Lyot coronagraph for WFIRST: high-contrast broadband testbed demonstration

    Science.gov (United States)

    Seo, Byoung-Joon; Cady, Eric; Gordon, Brian; Kern, Brian; Lam, Raymond; Marx, David; Moody, Dwight; Muller, Richard; Patterson, Keith; Poberezhskiy, Ilya; Mejia Prada, Camilo; Sidick, Erkin; Shi, Fang; Trauger, John; Wilson, Daniel

    2017-09-01

    Hybrid Lyot Coronagraph (HLC) is one of the two operating modes of the Wide-Field InfraRed Survey Telescope (WFIRST) coronagraph instrument. Since being selected by National Aeronautics and Space Administration (NASA) in December 2013, the coronagraph technology is being matured to Technology Readiness Level (TRL) 6 by 2018. To demonstrate starlight suppression in presence of expecting on-orbit input wavefront disturbances, we have built a dynamic testbed in Jet Propulsion Laboratory (JPL) in 2016. This testbed, named as Occulting Mask Coronagraph (OMC) testbed, is designed analogous to the WFIRST flight instrument architecture: It has both HLC and Shape Pupil Coronagraph (SPC) architectures, and also has the Low Order Wavefront Sensing and Control (LOWFS/C) subsystem to sense and correct the dynamic wavefront disturbances. We present upto-date progress of HLC mode demonstration in the OMC testbed. SPC results will be reported separately. We inject the flight-like Line of Sight (LoS) and Wavefront Error (WFE) perturbation to the OMC testbed and demonstrate wavefront control using two deformable mirrors while the LOWFS/C is correcting those perturbation in our vacuum testbed. As a result, we obtain repeatable convergence below 5 × 10-9 mean contrast with 10% broadband light centered at 550 nm in the 360 degrees dark hole with working angle between 3 λ/D and 9 λ/D. We present the key hardware and software used in the testbed, the performance results and their comparison to model expectations.

  7. Diagnosis of the hypothenar hammer syndrome by high-resolution contrast-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Winterer, J.T.; Ghanem, N.; Schaefer, O.; Lehnhardt, S.; Thuerl, C.; Laubenberger, J. [Department of Diagnostic Radiology, University of Freiburg, Hugstetter Strasse 55, 79106 Freiburg (Germany); Roth, M. [Center of Geriatric Medicine and Gerontology Freiburg, University of Freiburg, Hugstetter Strasse 55, 79106 Freiburg (Germany); Horch, R.E. [Department of Plastic and Hand Surgery, University of Freiburg, Hugstetter Strasse 55, 79106 Freiburg (Germany)

    2002-10-01

    Our objective was to describe the imaging features of hypothenar hammer syndrome using minimally invasive contrast-enhanced MR angiography in comparison with oscillography study. In five patients with hypothenar hammer syndrome Gd-BOPTA-enhanced elliptically reordered 3D pulse sequence MR was compared with oscillography findings and clinical symptoms focusing on angiographic appearance of vessel injury, distribution pattern of hand vasculature and joining branches between the radial and ulnar artery supply. All patients showed segmental occlusion at the site of trauma impact with varying involvement of the superficial palmar arch, common volar digital arteries. Embolic disease was present in 50% of patients and could be clearly identified with MRA. Good correspondence was found between angiographic appearance including the presence of collaterals, clinical symptoms and oscillography. Bilateral comparison was helpful in distinguishing between vessel variants and pathology. Bilateral Gd-BOPTA-enhanced MR angiography is a minimally invasive method to depict clearly the localization and extent of vessel injury in hypothenar hammer syndrome providing valuable information about distribution pattern of hand vasculature and presence of collaterals; however, no flow data can be obtained. (orig.)

  8. Multilocus sequence analysis of nectar pseudomonads reveals high genetic diversity and contrasting recombination patterns.

    Directory of Open Access Journals (Sweden)

    Sergio Alvarez-Pérez

    Full Text Available The genetic and evolutionary relationships among floral nectar-dwelling Pseudomonas 'sensu stricto' isolates associated to South African and Mediterranean plants were investigated by multilocus sequence analysis (MLSA of four core housekeeping genes (rrs, gyrB, rpoB and rpoD. A total of 35 different sequence types were found for the 38 nectar bacterial isolates characterised. Phylogenetic analyses resulted in the identification of three main clades [nectar groups (NGs 1, 2 and 3] of nectar pseudomonads, which were closely related to five intrageneric groups: Pseudomonas oryzihabitans (NG 1; P. fluorescens, P. lutea and P. syringae (NG 2; and P. rhizosphaerae (NG 3. Linkage disequilibrium analysis pointed to a mostly clonal population structure, even when the analysis was restricted to isolates from the same floristic region or belonging to the same NG. Nevertheless, signatures of recombination were observed for NG 3, which exclusively included isolates retrieved from the floral nectar of insect-pollinated Mediterranean plants. In contrast, the other two NGs comprised both South African and Mediterranean isolates. Analyses relating diversification to floristic region and pollinator type revealed that there has been more unique evolution of the nectar pseudomonads within the Mediterranean region than would be expected by chance. This is the first work analysing the sequence of multiple loci to reveal geno- and ecotypes of nectar bacteria.

  9. Geo-statistical model of Rainfall erosivity by using high temporal resolution precipitation data in Europe

    Science.gov (United States)

    Panagos, Panos; Ballabio, Cristiano; Borrelli, Pasquale; Meusburger, Katrin; Alewell, Christine

    2015-04-01

    Rainfall erosivity (R-factor) is among the 6 input factors in estimating soil erosion risk by using the empirical Revised Universal Soil Loss Equation (RUSLE). R-factor is a driving force for soil erosion modelling and potentially can be used in flood risk assessments, landslides susceptibility, post-fire damage assessment, application of agricultural management practices and climate change modelling. The rainfall erosivity is extremely difficult to model at large scale (national, European) due to lack of high temporal resolution precipitation data which cover long-time series. In most cases, R-factor is estimated based on empirical equations which take into account precipitation volume. The Rainfall Erosivity Database on the European Scale (REDES) is the output of an extensive data collection of high resolution precipitation data in the 28 Member States of the European Union plus Switzerland taking place during 2013-2014 in collaboration with national meteorological/environmental services. Due to different temporal resolutions of the data (5, 10, 15, 30, 60 minutes), conversion equations have been applied in order to homogenise the database at 30-minutes interval. The 1,541 stations included in REDES have been interpolated using the Gaussian Process Regression (GPR) model using as covariates the climatic data (monthly precipitation, monthly temperature, wettest/driest month) from WorldClim Database, Digital Elevation Model and latitude/longitude. GPR has been selected among other candidate models (GAM, Regression Kriging) due the best performance both in cross validation (R2=0.63) and in fitting dataset (R2=0.72). The highest uncertainty has been noticed in North-western Scotland, North Sweden and Finland due to limited number of stations in REDES. Also, in highlands such as Alpine arch and Pyrenees the diversity of environmental features forced relatively high uncertainty. The rainfall erosivity map of Europe available at 500m resolution plus the standard error

  10. High day- and night-time temperatures affect grain growth dynamics in contrasting rice genotypes

    NARCIS (Netherlands)

    Shi, Wanju; Yin, Xinyou; Struik, Paul C.; Solis, Celymar; Xie, Fangming; Schmidt, Ralf C.; Huang, Min; Zou, Yingbin; Ye, Changrong; Jagadish, S.V.K.

    2017-01-01

    Rice grain yield and quality are predicted to be highly vulnerable to global warming. Five genotypes including heat-tolerant and susceptible checks, a heat-tolerant near-isogenic line and two hybrids were exposed to control (31 °C/23 °C, day/night), high night-time temperature (HNT; 31 °C/30 °C),

  11. New Techniques for High-Contrast Imaging with ADI: The ACORNS-ADI SEEDS Data Reduction Pipeline

    Science.gov (United States)

    Brandt, Timothy D.; McElwain, Michael W.; Turner, Edwin L.; Abe, L.; Brandner, W.; Carson, J.; Egner, S.; Feldt, M.; Golota, T.; Grady, C. A.; hide

    2012-01-01

    We describe Algorithms for Calibration, Optimized Registration, and Nulling the Star in Angular Differential Imaging (ACORNS-ADI), a new, parallelized software package to reduce high-contrast imaging data, and its application to data from the Strategic Exploration of Exoplanets and Disks (SEEDS) survey. We implement seyeral new algorithms, includbg a method to centroid saturated images, a trimmed mean for combining an image sequence that reduces noise by up to approx 20%, and a robust and computationally fast method to compute the sensitivitv of a high-contrast obsen-ation everywhere on the field-of-view without introducing artificial sources. We also include a description of image processing steps to remove electronic artifacts specific to Hawaii2-RG detectors like the one used for SEEDS, and a detailed analysis of the Locally Optimized Combination of Images (LOCI) algorithm commonly used to reduce high-contrast imaging data. ACORNS-ADI is efficient and open-source, and includes several optional features which may improve performance on data from other instruments. ACORNS-ADI is freely available for download at www.github.com/t-brandt/acorns_-adi under a BSD license

  12. Removing high contrast artifacts via digital inpainting in cryo-electron tomography: an application of compressed sensing.

    Science.gov (United States)

    Song, Kahye; Comolli, Luis R; Horowitz, Mark

    2012-05-01

    To cope with poor quality in cryo-electron tomography images, electron-dense markers, such as colloidal goldbeads, are often used to assist image registration and analysis algorithms. However, these markers can create artifacts that occlude a specimen due to their high contrast, which can also cause failure of some image processing algorithms. One way of reducing these artifacts is to replace high contrast objects with pixel densities that blend into the surroundings in the projection domain before volume reconstruction. In this paper, we propose digital inpainting via compressed sensing (CS) as a new method to achieve this goal. We show that cryo-ET projections are sparse in the discrete cosine transform (DCT) domain, and, by finding the sparsest DCT domain decompositions given uncorrupted pixels, we can fill in the missing pixel values that are occluded by high contrast objects without discontinuities. Our method reduces visual artifacts both in projections and in tomograms better than conventional algorithms, such as polynomial interpolation and random noise inpainting. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. High-Resolution Ultrasound-Switchable Fluorescence Imaging in Centimeter-Deep Tissue Phantoms with High Signal-To-Noise Ratio and High Sensitivity via Novel Contrast Agents.

    Science.gov (United States)

    Cheng, Bingbing; Bandi, Venugopal; Wei, Ming-Yuan; Pei, Yanbo; D'Souza, Francis; Nguyen, Kytai T; Hong, Yi; Yuan, Baohong

    2016-01-01

    For many years, investigators have sought after high-resolution fluorescence imaging in centimeter-deep tissue because many interesting in vivo phenomena-such as the presence of immune system cells, tumor angiogenesis, and metastasis-may be located deep in tissue. Previously, we developed a new imaging technique to achieve high spatial resolution in sub-centimeter deep tissue phantoms named continuous-wave ultrasound-switchable fluorescence (CW-USF). The principle is to use a focused ultrasound wave to externally and locally switch on and off the fluorophore emission from a small volume (close to ultrasound focal volume). By making improvements in three aspects of this technique: excellent near-infrared USF contrast agents, a sensitive frequency-domain USF imaging system, and an effective signal processing algorithm, for the first time this study has achieved high spatial resolution (~ 900 μm) in 3-centimeter-deep tissue phantoms with high signal-to-noise ratio (SNR) and high sensitivity (3.4 picomoles of fluorophore in a volume of 68 nanoliters can be detected). We have achieved these results in both tissue-mimic phantoms and porcine muscle tissues. We have also demonstrated multi-color USF to image and distinguish two fluorophores with different wavelengths, which might be very useful for simultaneously imaging of multiple targets and observing their interactions in the future. This work has opened the door for future studies of high-resolution centimeter-deep tissue fluorescence imaging.

  14. Fish as bioindicators for trace element pollution from two contrasting lakes in the Eastern Rift Valley, Kenya: spatial and temporal aspects

    OpenAIRE

    Plessl, Christof; Otachi, Elick O.; K?rner, Wilfried; Avenant-Oldewage, Annemari?; Jirsa, Franz

    2017-01-01

    Lake Turkana and Lake Naivasha are two freshwater lakes in the Kenyan Rift Valley that differ significantly in water chemistry and anthropogenic influence: Lake Turkana is believed to be rather pristine and unpolluted, but a previous study has shown rather high levels of Li, Zn, and Cd in the migratory fish species Hydrocynus forskahlii, questioning this pristine status. Lake Naivasha is heavily influenced by agricultural activity in its catchment area and by direct water use, and high levels...

  15. Optophysiological approach to resolve neuronal action potentials with high spatial and temporal resolution in cultured neurons

    Directory of Open Access Journals (Sweden)

    Stephane ePages

    2011-10-01

    Full Text Available Cell to cell communication in the central nervous system is encoded into transient and local membrane potential changes (ΔVm. Deciphering the rules that govern synaptic transmission and plasticity entails to be able to perform Vm recordings throughout the entire neuronal arborization. Classical electrophysiology is, in most cases, not able to do so within small and fragile neuronal subcompartments. Thus, optical techniques based on the use of fluorescent voltage-sensitive dyes (VSDs have been developed. However, reporting spontaneous or small ΔVm from neuronal ramifications has been challenging, in part due to the limited sensitivity and phototoxicity of VSD-based optical measurements. Here we demonstrate the use of water soluble VSD, ANNINE-6plus, with laser scanning microscopy to optically record ΔVm in cultured neurons. We show that the sensitivity (> 10 % of fluorescence change for 100 mV depolarization and time response (submillisecond of the dye allows the robust detection of action potentials (APs even without averaging, allowing the measurement of spontaneous neuronal firing patterns. In addition, we show that back-propagating APs can be recorded, along distinct dendritic sites and within dendritic spines. Importantly, our approach does not induce any detectable phototoxic effect on cultured neurons. This optophysiological approach provides a simple, minimally invasive and versatile optical method to measure electrical activity in cultured neurons with high temporal (ms resolution and high spatial (µm resolution.

  16. Global rainfall erosivity assessment based on high-temporal resolution rainfall records.

    Science.gov (United States)

    Panagos, Panos; Borrelli, Pasquale; Meusburger, Katrin; Yu, Bofu; Klik, Andreas; Jae Lim, Kyoung; Yang, Jae E; Ni, Jinren; Miao, Chiyuan; Chattopadhyay, Nabansu; Sadeghi, Seyed Hamidreza; Hazbavi, Zeinab; Zabihi, Mohsen; Larionov, Gennady A; Krasnov, Sergey F; Gorobets, Andrey V; Levi, Yoav; Erpul, Gunay; Birkel, Christian; Hoyos, Natalia; Naipal, Victoria; Oliveira, Paulo Tarso S; Bonilla, Carlos A; Meddi, Mohamed; Nel, Werner; Al Dashti, Hassan; Boni, Martino; Diodato, Nazzareno; Van Oost, Kristof; Nearing, Mark; Ballabio, Cristiano

    2017-06-23

    The exposure of the Earth's surface to the energetic input of rainfall is one of the key factors controlling water erosion. While water erosion is identified as the most serious cause of soil degradation globally, global patterns of rainfall erosivity remain poorly quantified and estimates have large uncertainties. This hampers the implementation of effective soil degradation mitigation and restoration strategies. Quantifying rainfall erosivity is challenging as it requires high temporal resolution(<30 min) and high fidelity rainfall recordings. We present the results of an extensive global data collection effort whereby we estimated rainfall erosivity for 3,625 stations covering 63 countries. This first ever Global Rainfall Erosivity Database was used to develop a global erosivity map at 30 arc-seconds(~1 km) based on a Gaussian Process Regression(GPR). Globally, the mean rainfall erosivity was estimated to be 2,190 MJ mm ha-1 h-1 yr-1, with the highest values in South America and the Caribbean countries, Central east Africa and South east Asia. The lowest values are mainly found in Canada, the Russian Federation, Northern Europe, Northern Africa and the Middle East. The tropical climate zone has the highest mean rainfall erosivity followed by the temperate whereas the lowest mean was estimated in the cold climate zone.

  17. Diagnostic applications of an optoelectronic device for high temporal resolution of erythrocyte sedimentation (ESR-graphy)

    Science.gov (United States)

    Voeikov, Vladimir L.; Buravleva, Ekaterina; Bulargina, Yulia; Gurfinkel, Youri I.

    2001-10-01

    An automatic device for high-temporal resolution of the process of erythrocytes sedimentation in blood was designed. The position of the boundary between red blood and plasma is registered each 30 sec in several pipettes simultaneously with +/- 10 mkm precision. Data are processed by a PC and presented as velocity-time curves (ESR-grams) and the curves describing time evolution of the boundary position. ESR-grams demonstrate non-monotonous character of erythrocytes sedimentation in blood. Blood of particular donor being in a stable physiological state taken on different days is characterized by similar ESR-grams. Pathological deviations from a normal physiological state are reflected in the shortening of duration of each process stage and increasing of average sedimentation rate. Intravenous infusion of some medical preparations may lead either to improving (prolonging of macrokinetic stages, decreasing of sedimentation rate), or to worsening of studied parameters depending on an individual. The low extent of blood dilution with saline in vitro lead as a rule to decreasing of sedimentation rate and improving of microkinetic parameters of the process. Adding of highly diluted hydrogen peroxide to blood samples of patients resulted in the improving of sedimentation kinetics. ESR-graphy may widen opportunities of practical medicine in diagnostics, prognostics and drug therapy.

  18. Monitoring with high temporal resolution to search for optical transients in the wide field

    Science.gov (United States)

    Beskin, Grigory; Bondar, Sergey; Ivanov, Evgeny; Karpov, Sergey; Katkova, Elena; Pozanenko, Alexei; Guarnieri, Adriano; Bartolini, Corrado; Piccioni, Adalberto; Greco, Giuseppe; Molinari, Emilio; Covino, Stefano

    2008-02-01

    In order to detect and investigate short stochastic optical flares from a number of variable astrophysical objects (GRBs, SNs, flare stars, CVs, X-Ray binaries) of unknown localizations as well as near-earth objects (NEOs), both natural and artificial, it is necessary to perform the systematic monitoring of large regions of the sky with high temporal resolution. Here we describe the design of a system able to perform such a task, which consists of a wide-field camera with high time resolution able to detect and classify the transient events on a subsecond time scale, and a fast robotic telescope aimed to perform their detailed investigation. In a last few years we've created the prototype FAVOR wide-field camera, placed at North Caucasus near Russian 6-m telescope, and a complete two-telescope complex TORTOREM, combining TORTORA wide-field camera with REM robotic telescope and placed at La Silla ESO observatory. Its technical parameters and first results of operation are described.

  19. Estimation of crops biomass and evapotranspiration from high spatial and temporal resolutions remote sensing data

    Science.gov (United States)

    Claverie, Martin; Demarez, Valérie; Duchemin, Benoît.; Ceschia, Eric; Hagolle, Olivier; Ducrot, Danielle; Keravec, Pascal; Beziat, Pierre; Dedieu, Pierre

    2010-05-01

    Carbon and water cycles are closely related to agricultural activities. Agriculture has been indeed identified by IPCC 2007 report as one of the options to sequester carbon in soil. Concerning the water resources, their consumptions by irrigated crops are called into question in view of demographic pressure. In the prospect of an assessment of carbon production and water consumption, the use of crop models at a regional scale is a challenging issue. The recent availability of high spatial resolution (10 m) optical sensors associated to high temporal resolution (1 day) such as FORMOSAT-2 and, in the future, Venµs and SENTINEL-2 will offer new perspectives for agricultural monitoring. In this context, the objective of this work is to show how multi-temporal satellite observations acquired at high spatial resolution are useful for a regional monitoring of following crops biophysical variables: leaf area index (LAI), aboveground biomass (AGB) and evapotranspiration (ET). This study focuses on three summer crops dominant in South-West of France: maize, sunflower and soybean. A unique images data set (82 FORMOSAT-2 images over four consecutive years, 2006-2009) was acquired for this project. The experimental data set includes LAI and AGB measurements over eight agricultural fields. Two fields were intensively monitored where ET flux were measured with a 30 minutes time step using eddy correlation methods. The modelisation approach is based on FAO-56 method coupled with a vegetation functioning model based on Monteith theory: the SAFY model [5]. The model operates at a daily time step model to provide estimates of plant characteristics (LAI, AGB), soil conditions (soil water content) and water use (ET). As a key linking variable, LAI is deduced from FORMOSAT-2 reflectances images, and then introduced into the SAFY model to provide spatial and temporal estimates of these biophysical variables. Most of the SAFY parameters are crop related and have been fixed according to

  20. High-resolution motion compensated MRA in patients with congenital heart disease using extracellular contrast agent at 3 Tesla

    Directory of Open Access Journals (Sweden)

    Dabir Darius

    2012-10-01

    Full Text Available Abstract Background Using first-pass MRA (FP-MRA spatial resolution is limited by breath-hold duration. In addition, image quality may be hampered by respiratory and cardiac motion artefacts. In order to overcome these limitations an ECG- and navigator-gated high-resolution-MRA sequence (HR-MRA with slow infusion of extracellular contrast agent was implemented at 3 Tesla for the assessment of congenital heart disease and compared to standard first-pass-MRA (FP-MRA. Methods 34 patients (median age: 13 years with congenital heart disease (CHD were prospectively examined on a 3 Tesla system. The CMR-protocol comprised functional imaging, FP- and HR-MRA, and viability imaging. After the acquisition of the FP-MRA sequence using a single dose of extracellular contrast agent the motion compensated HR-MRA sequence with isotropic resolution was acquired while injecting the second single dose, utilizing the timeframe before viability imaging. Qualitative scores for image quality (two independent reviewers as well as quantitative measurements of vessel sharpness and relative contrast were compared using the Wilcoxon signed-rank test. Quantitative measurements of vessel diameters were compared using the Bland-Altman test. Results The mean image quality score revealed significantly better image quality of the HR-MRA sequence compared to the FP-MRA sequence in all vessels of interest (ascending aorta (AA, left pulmonary artery (LPA, left superior pulmonary vein (LSPV, coronary sinus (CS, and coronary ostia (CO; all p  Conclusions An ECG- and navigator-gated HR-MRA-protocol with infusion of extracellular contrast agent at 3 Tesla is feasible. HR-MRA delivers significantly better image quality and vessel sharpness compared to FP-MRA. It may be integrated into a standard CMR-protocol for patients with CHD without the need for additional contrast agent injection and without any additional examination time.

  1. High temporal resolution tracing of xylem CO2 transport in oak trees

    Science.gov (United States)

    Bloemen, Jasper; Ingrisch, Johannes; Bahn, Michael

    2016-04-01

    Carbon (C) allocation defines the flows of C between plant organs and their storage pools and metabolic processes and is therefore considered as an important determinant of forest C budgets and their responses to climate change. In trees, assimilates derived from leaf photosynthesis are transported via the phloem to above- and belowground sink tissues, where partitioning between growth, storage, and respiration occurs. At the same time, root- and aboveground respired CO2 can be dissolved in water and transported in the xylem tissue, thereby representing a C flux of large magnitude whose role in C allocation yet is unresolved. In this study, we infused 13C labeled water into the stem base of five year old potted oak (Quercus rubra) trees as a surrogate for respired CO2 to investigate the role of respired CO2 transport in trees in C allocation. We used high-resolution laser-based measurements of the isotopic composition of stem and soil CO2 efflux combined with stem gas probes to monitor the transport of 13C label. The high enrichment of the gas probes in the stem at the bottom of the canopy showed that the label was transported upwards from the base of the tree toward the top. During its ascent, the 13C label was removed from the transpiration stream and lost to the atmosphere at stem level, as was observed using the stem CO2 efflux laser-based measurements. This study is the first to show results from tracing xylem CO2 transport in trees at high temporal resolution using a 13C labeling approach. Moreover, they extend results from previous studies on internal CO2 transport in species with high transpiration rates like poplar to species with lower transpiration rates like oak. Internal transport of CO2 indicates that the current concepts of the tree C allocation need to be revisited, as they show that current gas exchange approach to estimating above- and belowground autotrophic respiration is inadequate.

  2. Pan-Tropical Forest Mapping by Exploiting Textures of Multi-Temporal High Resolution SAR Data

    Science.gov (United States)

    Knuth, R.; Eckardt, R.; Richter, N.; Schmullius, C.

    2012-12-01

    radar images were processed using an operational processing chain that includes radiometric transformation, noise reduction, and georeferencing of the SAR data. In places with pronounced topography both satellites were used as single pass interferometer to derive a digital surface model in order to perform an orthorectification followed by a topographic normalization of the SAR backscatter values. As prescribed by the FAO, the final segment-based classification algorithm was fed by multi-temporal backscatter information, a set of textural features, and information on the degree of coherence between the multi-temporal acquisitions. Validation with available high resolution optical imagery suggests that the produced forest maps possess an overall accuracy of 75 percent or higher.

  3. Generation of quantum beams in large clusters irradiated by Super-Intense, high - contrast femtosecond laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Faenov, A.Ya.; Pikuz, T.A. [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Kyoto (Japan); Joint Institute for High Temperatures RAS, Moscow (Russian Federation); Fukuda, Y.; Nakamura, T.; Bulanov, S.V.; Hayashi, Y.; Kotaki, H.; Pirozhkov, A.S.; Kawachi, T.; Kando, M. [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Kyoto (Japan); Skobelev, I.Yu.; Fortov, V.E. [Joint Institute for High Temperatures RAS, Moscow (Russian Federation); Chen, L.M.; Zhang, L.; Yan, W.C.; Yuan, D.W.; Mao, J.Y.; Wang, Z.H.; Ma, J.L. [Institute of Physics, Chinese Academy of Sciences, Beijing (China); Kato, Y. [The Graduate School for the Creation of New Photonics Industries, Hamamatsu, Shizuoka (Japan)

    2013-02-15

    A short review of our experimental studies on generation of photon and particle beams in submicron clusters irradiated by intense, high-contrast ({proportional_to} 10{sup 8}-10{sup 10}) femtosecond laser pulses is presented. It is shown that highlyefficient laser-cluster interaction allows creating bright sources of X-ray, high-energy electron and ion beams. The examples of applications of femtosecond-laser-produced cluster plasmas (FLPCP) for X-ray and ion beams radiography are presented. (copyright 2013 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. Contrast-enhanced spectral mammography (CESM) versus MRI in the high-risk screening setting: patient preferences and attitudes.

    Science.gov (United States)

    Phillips, Jordana; Miller, Matthew M; Mehta, Tejas S; Fein-Zachary, Valerie; Nathanson, Audrey; Hori, Wendy; Monahan-Earley, Rita; Slanetz, Priscilla J

    Our study evaluates patient preferences toward screening CESM versus MRI. As part of a prospective study, high-risk patients had breast MRI and CESM. Patients completed an anonymous survey to evaluate preferences regarding the two modalities. 88% of participants completed the survey. 79% preferred CESM over MRI if the exams had equal sensitivity. 89% would be comfortable receiving contrast as part of an annual screening test. High-risk populations may accept CESM as a screening exam and may prefer it over screening MRI if ongoing trials demonstrate screening CESM to be clinically non-inferior MRI. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Robust design of Si/Si3N4 high contrast grating mirror for mid-infrared VCSEL application

    CERN Document Server

    Chevallier, Christyves; Genty, Frédéric; Jacquet, Joel

    2012-01-01

    A Si/Si3N4 high contrast grating mirror has been designed for a VCSEL integration in mid-infrared ({\\lambda} = 2.65 $\\mu$m). The use of an optimization algorithm which maximizes a VCSEL mirror quality factor allowed the adjustment of the grating parameters while keeping large and shallow grating pattern. The robustness with respect to fabrication error has been enhanced thanks to a precise study of the grating dimension tolerances. The final mirror exhibits large high reflectivity bandwidth with a polarization selectivity and several percent of tolerance on the grating dimensions.

  6. General Tool for Evaluating High-Contrast Coronagraphic Telescope Performance Error Budgets

    Science.gov (United States)

    Marchen, Luis F.

    2011-01-01

    The Coronagraph Performance Error Budget (CPEB) tool automates many of the key steps required to evaluate the scattered starlight contrast in the dark hole of a space-based coronagraph. The tool uses a Code V prescription of the optical train, and uses MATLAB programs to call ray-trace code that generates linear beam-walk and aberration sensitivity matrices for motions of the optical elements and line-of-sight pointing, with and without controlled fine-steering mirrors (FSMs). The sensitivity matrices are imported by macros into Excel 2007, where the error budget is evaluated. The user specifies the particular optics of interest, and chooses the quality of each optic from a predefined set of PSDs. The spreadsheet creates a nominal set of thermal and jitter motions, and combines that with the sensitivity matrices to generate an error budget for the system. CPEB also contains a combination of form and ActiveX controls with Visual Basic for Applications code to allow for user interaction in which the user can perform trade studies such as changing engineering requirements, and identifying and isolating stringent requirements. It contains summary tables and graphics that can be instantly used for reporting results in view graphs. The entire process to obtain a coronagraphic telescope performance error budget has been automated into three stages: conversion of optical prescription from Zemax or Code V to MACOS (in-house optical modeling and analysis tool), a linear models process, and an error budget tool process. The first process was improved by developing a MATLAB package based on the Class Constructor Method with a number of user-defined functions that allow the user to modify the MACOS optical prescription. The second process was modified by creating a MATLAB package that contains user-defined functions that automate the process. The user interfaces with the process by utilizing an initialization file where the user defines the parameters of the linear model

  7. High spatial resolution hard X-ray microscope using X-ray refractive lens and phase contrast imaging experiments

    CERN Document Server

    Kohmura, Y; Takeuchi, A; Takano, H; Suzuki, Y; Ishikawa, T; Ohigashi, T; Yokosuka, H

    2001-01-01

    A high spatial resolution X-ray microscope was constructed using an X-ray refractive lens as an objective. The spatial resolution was tested using 18 keV X-ray. A 0.4 mu m line and 0.4 mu m space tantalum test pattern was successfully resolved. Using the similar setup with the addition of a phase plate, a Zernike type phase-contrast microscopy experiment was carried out for the phase retrieval of the samples. Two-dimensional phase-contrast images were successfully taken for the first time in the hard X-ray region. Images of a gold mesh sample were analyzed and the validity of this method was indicated. An improvement of the lens, however, is required for the precise phase retrieval of the samples.

  8. Reflective dual-mode liquid crystal display possessing low power consumption and high contrast ratio under ambient light.

    Science.gov (United States)

    Kim, Taehyung; Lee, Joong Ha; Yoon, Tae-Hoon; Choi, Suk-Won

    2012-07-02

    We propose a reflective dual-mode liquid crystal display (RD-LCD) which has advantages of long memory retention time and high contrast ratio. The proposed device adopts ideal bistable characteristics, a cell thickness over pitch (d/p) of 0.25. It can realize long memory retention time, thereby reducing power consumption. In addition, an optical configuration for the RD-LCD makes low light leakages at dark state and shows good dispersion characteristics in both dark and bright states over the entire visible ranges. We experimentally confirmed retention time over 6 months in memory mode and memory and dynamic contrast ratios of 47:1 and 43:1 under ambient light, respectively. As a result, the proposed RD-LCD demonstrates convincingly that it is a candidate for green display.

  9. Repeated, long-distance migrations by a philopatric predator targeting highly contrasting ecosystems

    Science.gov (United States)

    Lea, James S. E.; Wetherbee, Bradley M.; Queiroz, Nuno; Burnie, Neil; Aming, Choy; Sousa, Lara L.; Mucientes, Gonzalo R.; Humphries, Nicolas E.; Harvey, Guy M.; Sims, David W.; Shivji, Mahmood S.

    2015-06-01

    Long-distance movements of animals are an important driver of population spatial dynamics and determine the extent of overlap with area-focused human activities, such as fishing. Despite global concerns of declining shark populations, a major limitation in assessments of population trends or spatial management options is the lack of information on their long-term migratory behaviour. For a large marine predator, the tiger shark Galeocerdo cuvier, we show from individuals satellite-tracked for multiple years (up to 1101 days) that adult males undertake annually repeated, round-trip migrations of over 7,500 km in the northwest Atlantic. Notably, these migrations occurred between the highly disparate ecosystems of Caribbean coral reef regions in winter and high latitude oceanic areas in summer, with strong, repeated philopatry to specific overwintering insular habitat. Partial migration also occurred, with smaller, immature individuals displaying reduced migration propensity. Foraging may be a putative motivation for these oceanic migrations, with summer behaviour showing higher path tortuosity at the oceanic range extremes. The predictable migratory patterns and use of highly divergent ecosystems shown by male tiger sharks appear broadly similar to migrations seen in birds, reptiles and mammals, and highlight opportunities for dynamic spatial management and conservation measures of highly mobile sharks.

  10. A Simplified Method for Upscaling Composite Materials with High Contrast of the Conductivity

    KAUST Repository

    Ewing, R.

    2009-01-01

    A large class of industrial composite materials, such as metal foams, fibrous glass materials, mineral wools, and the like, are widely used in insulation and advanced heat exchangers. These materials are characterized by a substantial difference between the thermal properties of the highly conductive materials (glass or metal) and the insulator (air) as well as low volume fractions and complex network-like structures of the highly conductive components. In this paper we address the important issue for the engineering practice of developing fast, reliable, and accurate methods for computing the macroscopic (upscaled) thermal conductivities of such materials. We assume that the materials have constant macroscopic thermal conductivity tensors, which can be obtained by upscaling techniques based on the postprocessing of a number of linearly independent solutions of the steady-state heat equation on representative elementary volumes (REVs). We propose, theoretically justify, and computationally study a numerical method for computing the effective conductivities of materials for which the ratio δ of low and high conductivities satisfies δ ≪ 1. We show that in this case one needs to solve the heat equation in the region occupied by the highly conductive media only. Further, we prove that under certain conditions on the microscale geometry the proposed method gives an approximation that is O(δ)-close to the upscaled conductivity. Finally, we illustrate the accuracy and the limitations of the method on a number of numerical examples. © 2009 Society for Industrial and Applied Mathematics.

  11. High resolution myocardial magnetic resonance stress perfusion imaging at 3 T using a 1 M contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, Bernhard D.; Seeger, Achim; Doering, Joerg; Kramer, Ulrich; Fenchel, Michael; Claussen, Claus D.; Miller, Stephan [Eberhard Karls University Tuebingen, Department for Diagnostic Radiology, Tuebingen (Germany); Doesch, Christina; Hoevelborn, Tobias; Gawaz, Meinrad P. [Eberhard Karls University Tuebingen, Department for Cardiology, Tuebingen (Germany)

    2010-03-15

    Stress perfusion magnetic resonance imaging (MSPMRI) is an established technique for the assessment of myocardial perfusion. Shortcomings at 1.5 T are low signal to noise ratio (SNR) and contrast to noise ratio (CNR). One approach to overcome these shortcomings is to increase field strength and contrast concentration. The aim of our study was to investigate the diagnostic capability of high resolution MSPMRI at 3-T field strength using a 1 M contrast agent. Fifty-seven patients (62.3{+-} 11.0 years) with symptoms of coronary artery disease (CAD) were examined at 3 T. MMRSPI was assessed using a 2D saturation recovery gradient echo (SR GRE) sequence in short axis orientation (TR 1.9 ms, TE 1.0 ms, flip 12 , 0.1 mmol gadobutrol/kg body weight (bw), 140{mu}g adenosine/kg bw/min). Perfusion images were assessed visually and semiquantitatively (upslope, peak signal intensity (SI), and myocardial perfusion reserve index (MPRI)). Standard of reference was invasive coronary angiography. Stress-induced hypoperfusion was found in 43 patients. Sensitivity for hemodynamically relevant CAD (stenoses greater than 70%) was 95%/98%, specificity 80%/87%, diagnostic accuracy 91%/95% (reader 1/reader 2). The MPRI was significantly lower in hypoperfused myocardium (1.3 {+-} 0.2) compared with normal myocardium (2.6 {+-} 0.7). High resolution MMRSPI at 3 T using 1 M contrast agent under daily routine conditions provides reliable detection of stress-induced myocardial hypoperfusion with higher diagnostic accuracy than 1.5-T conditions. (orig.)

  12. Temporal and voltage stress stability of high performance indium-zinc-oxide thin film transistors

    Science.gov (United States)

    Song, Yang; Katsman, Alexander; Butcher, Amy L.; Paine, David C.; Zaslavsky, Alexander

    2017-10-01

    Thin film transistors (TFTs) based on transparent oxide semiconductors, such as indium zinc oxide (IZO), are of interest due to their improved characteristics compared to traditional a-Si TFTs. Previously, we reported on top-gated IZO TFTs with an in-situ formed HfO2 gate insulator and IZO active channel, showing high performance: on/off ratio of ∼107, threshold voltage VT near zero, extracted low-field mobility μ0 = 95 cm2/V·s, and near-perfect subthreshold slope at 62 mV/decade. Since device stability is essential for technological applications, in this paper we report on the temporal and voltage stress stability of IZO TFTs. Our devices exhibit a small negative VT shift as they age, consistent with an increasing carrier density resulting from an increasing oxygen vacancy concentration in the channel. Under gate bias stress, freshly annealed TFTs show a negative VT shift during negative VG gate bias stress, while aged (>1 week) TFTs show a positive VT shift during negative VG stress. This indicates two competing mechanisms, which we identify as the field-enhanced generation of oxygen vacancies and the field-assisted migration of oxygen vacancies, respectively. A simplified kinetic model of the vacancy concentration evolution in the IZO channel under electrical stress is provided.

  13. Soil wetting processes at high temporal resolution in a semiarid mediterranean watershed with scattered tree cover

    Science.gov (United States)

    Lozano-Parra, Javier; van Schaik, Loes; Schnabel, Susanne; Gómez-Gutiérrez, Álvaro

    2015-04-01

    Soil wetting processes play a key role for the distribution of water and solutes and thereby for the water availability for plants. However, characterization of such processes (from slower to faster flows), frequency of occurrence, and factors that cause them, are still poorly known. This characterization is important in hydrological studies because enables a better understanding of spatio-temporal variability of water resources and allows improving the design of models. Using a method based on the maximal soil water increase registered by a sensor over a minimum given time interval during a rainfall event, types of soil wetting processes were classified and quantified. For this, capacitance sensors which registered the volumetric water content at high temporal resolution (30-min) along of more than two hydrological years (mainly for 2010-2011 and 2011-2012), were installed in soil profiles at 5, 15 cm, and 5 cm above the bedrock and depending on soil depth. This distribution along the soil profile is justified because soils are generally very shallow and most of the roots are concentrated in the upper layer. The sensors were gathered in 9 soil moisture stations characterized by lithology, topographic position, as well as by different vegetation covers: under tree canopy, under shrub, and in open spaces or grasslands. Besides, the data mining technique Multivariate Adaptive Regression Spline (MARS) was used to identify and rank the factors influencing flow types as well as modelling their occurrence. The work was carried out in an experimental catchment of the Spanish region of Extremadura. Results indicated that there is a general behavior or pattern of soil moisture dynamics in the catchment with a dominant occurrence of slower soil wetting processes (>50%), which may be considered as matrix flows, and a low occurrence of those faster processes (process, so that the ecological role of both flow types becomes prominent in water-limited environments. Statistical

  14. Spatial distribution and temporal development of high-mountain lakes in western Austria

    Science.gov (United States)

    Merkl, Sarah; Emmer, Adam; Mergili, Martin

    2015-04-01

    Glacierized high-mountain environments are characterized by active morphodynamics, favouring the rapid appearance and disappearance of lakes. On the one hand, such lakes indicate high-mountain environmental changes such as the retreat of glaciers. On the other hand, they are sometimes susceptible to sudden drainage, leading to glacial lake outburst floods (GLOFs) putting the downstream population at risk. Whilst high-mountain lakes have been intensively studied in the Himalayas, the Pamir, the Andes or the Western Alps, this is not the case for the Eastern Alps. A particular research gap, which is attacked with the present work, concerns the western part of Austria. We consider a study area of approx. 6,140 km², covering the central Alps over most of the province of Tyrol and part of the province of Salzburg. All lakes ≥250 m² located higher than 2000 m asl are mapped from high-resolution Google Earth imagery and orthophotos. The lakes are organized into seven classes: (i) ice-dammed; near-glacial (ii) moraine-dammed and (iii) bedrock-dammed; (iv) moraine-dammed and (v) bedrock-dammed distant to the recent glaciers; (vi) landslide-dammed; (vii) anthropogenic. The temporal development of selected lakes is investigated in detail, using aerial photographs dating back to the 1950s. 1045 lakes are identified in the study area. Only eight lakes are ice-dammed (i). One third of all lakes is located in the immediate vicinity of recent glacier tongues, half of them impounded by moraine (ii), half of them by bedrock (iii). Two thirds of all lakes are impounded by features (either moraines or bedrock) shaped by LIA or Pleistocenic glaciers at some distance to the present glacier tongues (iv and v). Only one landslide-dammed lake (vi) is identified in the study area, whilst 21 lakes are of anthropogenic origin (vii). 72% of all lakes are found at 2250-2750 m asl whilst less than 2% are found above 3000 m asl. The ratio of rock-dammed lakes increases with increasing

  15. Low-stress and high-stress singing have contrasting effects on glucocorticoid response

    Directory of Open Access Journals (Sweden)

    Daisy eFancourt

    2015-09-01

    Full Text Available Performing music in public is widely recognised as a potentially stress-inducing activity. However, despite the interest in music performance as an acute psychosocial stressor, there has been relatively little research on the effects of public performance on the endocrine system. This study examined the impact of singing in a low-stress performance situation and a high-stress live concert on levels of glucocorticoids (cortisol and cortisone in 15 professional singers. The results showed a significant decrease in both cortisol and cortisone across the low-stress condition, suggesting that singing in itself is a stress-reducing (and possibly health-promoting activity, but significant increases across the high-stress condition. This is the first study to demonstrate that singing affects glucocorticoid responses and that these responses are modulated by the conditions of performance.

  16. High contrast switchability of VO2 based metamaterial absorbers with ITO ground plane.

    Science.gov (United States)

    Pradhan, Jitendra K; Anantha Ramakrishna, S; Rajeswaran, Bharathi; Umarji, Arun M; Achanta, Venu Gopal; Agarwal, Amit K; Ghosh, Amitava

    2017-04-17

    A metamaterial consisting of an array of gold micro-disks, separated from a ground plane of indium tin oxide (ITO) by a thin film of vanadium dioxide (VO2), behaves as a perfect absorber at infrared (IR) frequencies at room temperature. This metamaterial, which is transparent to visible light, can be switched to a highly reflecting state for IR light by heating the metamaterial to temperatures larger than the metal-insulator phase transition temperature 68°C of VO2. For a disk diameter of 1.5 μm and VO2 film thickness of 320 nm, two absorption bands are obtained: one, that arises from the metamaterial resonance; and a second peak that arises principally from a Fabry-Pérot resonance. A large change (>78%) occurs in the reflectivity between the low and high temperature phases. IR emittance of the metamaterial was measured with IR cameras and shown to be switchable to result in low emittance at high temperature. Optical readout of the state of VO2 within the metamaterial is demonstrated.

  17. High temporal and spatial variability of atmospheric-methane oxidation in Alpine glacier-forefield soils.

    Science.gov (United States)

    Chiri, Eleonora; Nauer, Philipp A; Rainer, Edda-Marie; Zeyer, Josef; Schroth, Martin H

    2017-07-07

    Glacier-forefield soils can provide a substantial sink for atmospheric CH4, facilitated by aerobic methane-oxidizing bacteria (MOB). However, MOB activity, abundance, and community structure may be affected by soil age, location in different forefield landforms, and temporal fluctuations in soil-physical parameters. We assessed spatial and temporal variability of atmospheric CH4 oxidation in an Alpine glacier forefield during the snow-free season 2013. We quantified CH4 flux in soils of increasing age and in different landforms (sandhill, terrace, floodplain) using soil-gas-profile and static flux-chamber methods. To determine MOB abundance and community structure, we employed pmoA-gene-based quantitative PCR and targeted-amplicon sequencing. Uptake of CH4 increased in magnitude and decreased in variability with increasing soil age. Sandhill soils exhibited CH4 uptake ranging from -0.03- -3.7 mg CH4 m-2 d-1 Floodplain and terrace soils exhibited smaller uptake and even intermittent CH4 emissions. Linear mixed-effect models indicated that soil age and landform were dominating factors shaping CH4 flux, followed by cumulative rainfall (weighted sum ≤ 4 d prior to sampling). Of 31 MOB operational taxonomic units retrieved, ∼30% were potentially novel, and ∼50% were affiliated with Upland Soil Clusters gamma and alpha. The MOB community structures in floodplain and terrace soils were nearly identical, but differed significantly from highly variable sandhill-soil communities. We conclude that soil age and landform modulate the soil CH4 sink strength in glacier forefields, and recent rainfall affects its short-term variability. This should be taken into account when including this environment in future CH4 inventories.Importance Oxidation of methane (CH4) in well-drained, "upland" soils is an important mechanism for the removal of this potent greenhouse gas from the atmosphere. It is largely mediated by aerobic, methane-oxidizing bacteria (MOB). Whereas there is

  18. Evaluation of high resolution spatio-temporal precipitation extremes from a stochastic weather generator

    DEFF Research Database (Denmark)

    Sørup, Hjalte Jomo Danielsen; Christensen, O. B.; Arnbjerg-Nielsen, Karsten

    gauges in the model area. The spatio-temporal performance of the model with respect to precipitation extremes is evaluated in the points of a 2x2 km regular grid covering the full model area. The model satisfactorily reproduces the extreme behaviour of the observed precipitation with respect to event...... intensity levels and unconditional spatial correlation when evaluated using an event based ranking approach at point scale and an advanced spatio-temporal coupling of extreme events. Prospectively the model can be used as a tool to evaluate the impact of climate change without relying onprecipitation output......Spatio-temporal rainfall is modelled for the North-Eastern part of Zealand (Denmark) using the Spatio-Temporal Neyman-Scott Rectangular Pulses model as implemented in the RainSim software. Hourly precipitation series for fitting the model are obtained from a dense network of tipping bucket rain...

  19. Failure Prognosis of High Voltage Circuit Breakers with Temporal Latent Dirichlet Allocation

    National Research Council Canada - National Science Library

    Gaoyang Li; Xiaohua Wang; Aijun Yang; Mingzhe Rong; Kang Yang

    2017-01-01

    .... In this paper, a temporal Latent Dirichlet Allocation (TLDA) framework is proposed to proactively reduce the cardinality of the event categories and estimate the future failure distributions by automatically uncovering the hidden patterns...

  20. The dynamic response of high pressure phase of Si using phase contrast imaging and X-ray diffraction

    Science.gov (United States)

    Lee, H. J.; Galtier, E.; Xing, Z.; Gleason, A.; Granados, E.; Tavella, F.; Schropp, A.; Seiboth, F.; Schroer, C.; Higginbotham, A.; Brown, S.; Arnold, B.; Curiel, R.; Peterswright, D.; Fry, A.; Nagler, B.

    2015-11-01

    Static compression studies have revealed that crystalline silicon undergoes phase transitions from a cubic diamond structure to a variety of phases including body-centered tetragonal phase, an orthorhombic phase, and a hexagonal primitive phase. However, the dynamic response of silicon at high pressure is not well understood. Phase contrast imaging has proven to be a powerful tool for probing density changes caused by the shock propagation into a material. With respect to the elastic and plastic compression, we image shock waves in Si with high spatial resolution using the LCLS X-ray free electron laser and Matter in Extreme Conditions instrument. In this study, the long pulse optical laser with pseudoflat top shape creates high pressures up to 60 GPa. We also measure the crystal structure by observing the X-ray diffraction orthogonal to the shock propagation direction over a range of pressure. In this talk, we will present the capability of simultaneously performing phase contrast imaging and in situ X-ray diffraction during shock loading and will discuss the dynamic response of Si in high pressure phases

  1. Ultra-Low Loss, Chip-Based Hollow-Core Waveguide Using High-Contrast Grating

    Science.gov (United States)

    2011-09-28

    delay circuit can be realized with a device loss that is order of magnitude lower than the current state- of-the-art in on-chip semiconductor...demonstrated as a high reflection mirrors at normal incident angle for VCSELs [5-7]. An HCG structure consists of a single layer of grating composed of a...nonlinearity measurement is currently limited by maximum power level of our EDF A ( ~ 18 dBm), the noise floor of OSA and the insufficient length of the

  2. High temporal resolution mapping of seismic noise sources using heterogeneous supercomputers

    Science.gov (United States)

    Gokhberg, Alexey; Ermert, Laura; Paitz, Patrick; Fichtner, Andreas

    2017-04-01

    Time- and space-dependent distribution of seismic noise sources is becoming a key ingredient of modern real-time monitoring of various geo-systems. Significant interest in seismic noise source maps with high temporal resolution (days) is expected to come from a number of domains, including natural resources exploration, analysis of active earthquake fault zones and volcanoes, as well as geothermal and hydrocarbon reservoir monitoring. Currently, knowledge of noise sources is insufficient for high-resolution subsurface monitoring applications. Near-real-time seismic data, as well as advanced imaging methods to constrain seismic noise sources have recently become available. These methods are based on the massive cross-correlation of seismic noise records from all available seismic stations in the region of interest and are therefore very computationally intensive. Heterogeneous massively parallel supercomputing systems introduced in the recent years combine conventional multi-core CPU with GPU accelerators and provide an opportunity for manifold increase and computing performance. Therefore, these systems represent an efficient platform for implementation of a noise source mapping solution. We present the first results of an ongoing research project conducted in collaboration with the Swiss National Supercomputing Centre (CSCS). The project aims at building a service that provides seismic noise source maps for Central Europe with high temporal resolution (days to few weeks depending on frequency and data availability). The service is hosted on the CSCS computing infrastructure; all computationally intensive processing is performed on the massively parallel heterogeneous supercomputer "Piz Daint". The solution architecture is based on the Application-as-a-Service concept in order to provide the interested external researchers the regular access to the noise source maps. The solution architecture includes the following sub-systems: (1) data acquisition responsible for

  3. Spatial and Temporal High Processing of Visual and Auditory Stimuli in Cervical Dystonia.

    Science.gov (United States)

    Chillemi, Gaetana; Calamuneri, Alessandro; Morgante, Francesca; Terranova, Carmen; Rizzo, Vincenzo; Girlanda, Paolo; Ghilardi, Maria Felice; Quartarone, Angelo

    2017-01-01

    Investigation of spatial and temporal cognitive processing in idiopathic cervical dystonia (CD) by means of specific tasks based on perception in time and space domains of visual and auditory stimuli. Previous psychophysiological studies have investigated temporal and spatial characteristics of neural processing of sensory stimuli (mainly somatosensorial and visual), whereas the definition of such processing at higher cognitive level has not been sufficiently addressed. The impairment of time and space processing is likely driven by basal ganglia dysfunction. However, other cortical and subcortical areas, including cerebellum, may also be involved. We tested 21 subjects with CD and 22 age-matched healthy controls with 4 recognition tasks exploring visuo-spatial, audio-spatial, visuo-temporal, and audio-temporal processing. Dystonic subjects were subdivided in three groups according to the head movement pattern type (lateral: Laterocollis, rotation: Torticollis) as well as the presence of tremor (Tremor). We found significant alteration of spatial processing in Laterocollis subgroup compared to controls, whereas impairment of temporal processing was observed in Torticollis subgroup compared to controls. Our results suggest that dystonia is associated with a dysfunction of temporal and spatial processing for visual and auditory stimuli that could underlie the well-known abnormalities in sequence learning. Moreover, we suggest that different movement pattern type might lead to different dysfunctions at cognitive level within dystonic population.

  4. The Architecture of the LkCa 15 Transitional Disk Revealed By High-Contrast Imaging

    Science.gov (United States)

    Thalmann, C.; Mulders, G. D.; Hodapp, K.; Janson, M.; Grady, C.A.; Min, M.; de Juan Ovelar, M.; Carson, J.; Brandt, T.; Bonnefoy, M.; hide

    2014-01-01

    We present four new epochs of Ks-band images of the young pre-transitional disk around LkCa 15 and perform extensive forward modeling to derive the physical parameters of the disk. We find indications of strongly anisotropic scattering (Henyey-Greenstein g = 0.67 (+0.18/-0.11)) and a significantly tapered gap edge ("round wall") but see no evidence that the inner disk, whose existence is predicted by the spectral energy distribution, shadows the outer regions of the disk visible in our images.We marginally confirm the existence of an offset between the disk center and the star along the line of nodes; however, the magnitude of this offset (x = 27 (+19/-20) mas) is notably lower than that found in our earlier H-band images. Intriguingly, we also find an offset of y = 69 (+49/-25) mas perpendicular to the line of nodes at high significance. If confirmed by future observations, this would imply a highly elliptical - or otherwise asymmetric - disk gap with an effective eccentricity of e ˜ 0.3. Such asymmetry would most likely be the result of dynamical sculpting by one or more unseen planets in the system. Finally, we find that the bright arc of scattered light we see in direct imaging observations originates from the near side of the disk and appears brighter than the far side because of strong forward scattering.

  5. Tropical Refuges with Exceptionally High Phylogenetic Diversity Reveal Contrasting Phylogenetic Structures

    Directory of Open Access Journals (Sweden)

    Lara Pugliesi

    2015-01-01

    Full Text Available Loss of phylogenetic diversity (PD has gained increasing attention in conservation biology. However, PD is not equally distributed in a phylogeny and can be better assessed when species relatedness (phylogenetic structure: PS is also considered. Here, we investigate PD and PS in two refuges of biodiversity in northeastern Brazil: the Bahia Costal Forest (BCF in the Atlantic Forest domain and Chapada Diamantina (CD in the Caatinga domain. We used geographic data of 205 species at two spatial scales and a chronogram of Apocynaceae based on matK sequences to estimate PD and PS. Our results show an exceptionally high PD in both refuges, overdispersed in BCF and clustered in CD, although this difference is less evident or absent for recent relationships, especially at a smaller spatial scale. Overall, PS suggests long-term competitive exclusion under climatic stability, currently balanced by habitat filtering, in BCF, and biome conservatism and limited dispersal leading to in situ diversification and high density of microendemics in CD. The phylogenetically clustered flora in CD, also threatened by climate changes, are naturally more vulnerable than BCF. Therefore, while in situ conservation may ensure protection of biodiversity in BCF, emergency ex situ conservation is strongly recommended in CD.

  6. Identification and characterisation of local aerosol sources using high temporal resolution measurements.

    Science.gov (United States)

    Contini, D; Donateo, A; Cesari, D; Belosi, F; Francioso, S

    2010-09-01

    Aerosol and gaseous pollution measurements were carried out at an urban background site in the south of Italy located near an industrial complex. Collection of 24 h samples of PM10 and PM2.5 and successive chemical quantification of metals were performed. Data were compared with measurements taken at a suburban background site, located at 25 km distance. The comparison showed the presence of an industrial contribution with a well defined chemical emission profile, similar, in terms of metals content, to urban emissions. As this made difficult the quantitative characterisation of the contribution of the two sources to atmospheric PM, a statistical method based on the treatment of data arising from high temporal resolution measurements was developed. Data were taken with a micrometeorological station based on an integrating nephelometer (Mie pDR-1200) for optical detection of PM2.5 concentration, with successive evaluation of vertical turbulent fluxes using the eddy-correlation method. Results show that the contribution from the two sources (urban emissions and industrial releases) have a very different behaviour, with the industrial contribution being present at high wind velocity with short concentration peaks (average duration 4 min) associated to strong positive and negative vertical fluxes. The estimated contribution to PM2.5 is 2.3% over long-term averages. The urban emissions are mainly present at low wind velocity, with longer concentration peaks in the morning and late evening hours, generally associated to small positive vertical fluxes. The characterisation of the contribution was performed using deposition velocity V(d) that is on average -3.5 mm s(-1) and has a diurnal pattern, with negligible values during the night and a minimum value of around -9 mm s(-1) late in the afternoon. Results show a correlation between V(d), friction velocity and wind velocity that could be the basis for a parameterisation of V(d) to be used in dispersion codes.

  7. Highly temporally resolved response to seasonal surface melt of the Zachariae and 79N outlet glaciers in Northeast Greenland

    DEFF Research Database (Denmark)

    Rathmann, N. M.; Hvidberg, C. S.; Solgaard, A. M.

    2017-01-01

    The seasonal response to surface melting of the Northeast Greenland Ice Stream outlets, Zachariae and 79N, is investigated using new highly temporally resolved surface velocity maps for 2016 combined with numerical modelling. The seasonal speed-up at 79N of 0.15km/yr is suggested to be driven by ...

  8. Retooling Laser Speckle Contrast Analysis Algorithm to Enhance Non-Invasive High Resolution Laser Speckle Functional Imaging of Cutaneous Microcirculation

    Science.gov (United States)

    Gnyawali, Surya C.; Blum, Kevin; Pal, Durba; Ghatak, Subhadip; Khanna, Savita; Roy, Sashwati; Sen, Chandan K.

    2017-01-01

    Cutaneous microvasculopathy complicates wound healing. Functional assessment of gated individual dermal microvessels is therefore of outstanding interest. Functional performance of laser speckle contrast imaging (LSCI) systems is compromised by motion artefacts. To address such weakness, post-processing of stacked images is reported. We report the first post-processing of binary raw data from a high-resolution LSCI camera. Sharp images of low-flowing microvessels were enabled by introducing inverse variance in conjunction with speckle contrast in Matlab-based program code. Extended moving window averaging enhanced signal-to-noise ratio. Functional quantitative study of blood flow kinetics was performed on single gated microvessels using a free hand tool. Based on detection of flow in low-flow microvessels, a new sharp contrast image was derived. Thus, this work presents the first distinct image with quantitative microperfusion data from gated human foot microvasculature. This versatile platform is applicable to study a wide range of tissue systems including fine vascular network in murine brain without craniotomy as well as that in the murine dorsal skin. Importantly, the algorithm reported herein is hardware agnostic and is capable of post-processing binary raw data from any camera source to improve the sensitivity of functional flow data above and beyond standard limits of the optical system.

  9. Spatial and temporal heterogeneity in high-grade serous ovarian cancer: a phylogenetic analysis.

    Directory of Open Access Journals (Sweden)

    Roland F Schwarz

    2015-02-01

    Full Text Available The major clinical challenge in the treatment of high-grade serous ovarian cancer (HGSOC is the development of progressive resistance to platinum-based chemotherapy. The objective of this study was to determine whether intra-tumour genetic heterogeneity resulting from clonal evolution and the emergence of subclonal tumour populations in HGSOC was associated with the development of resistant disease.Evolutionary inference and phylogenetic quantification of heterogeneity was performed using the MEDICC algorithm on high-resolution whole genome copy number profiles and selected genome-wide sequencing of 135 spatially and temporally separated samples from 14 patients with HGSOC who received platinum-based chemotherapy. Samples were obtained from the clinical CTCR-OV03/04 studies, and patients were enrolled between 20 July 2007 and 22 October 2009. Median follow-up of the cohort was 31 mo (interquartile range 22-46 mo, censored after 26 October 2013. Outcome measures were overall survival (OS and progression-free survival (PFS. There were marked differences in the degree of clonal expansion (CE between patients (median 0.74, interquartile range 0.66-1.15, and dichotimization by median CE showed worse survival in CE-high cases (PFS 12.7 versus 10.1 mo, p = 0.009; OS 42.6 versus 23.5 mo, p = 0.003. Bootstrap analysis with resampling showed that the 95% confidence intervals for the hazard ratios for PFS and OS in the CE-high group were greater than 1.0. These data support a relationship between heterogeneity and survival but do not precisely determine its effect size. Relapsed tissue was available for two patients in the CE-high group, and phylogenetic analysis showed that the prevalent clonal population at clinical recurrence arose from early divergence events. A subclonal population marked by a NF1 deletion showed a progressive increase in tumour allele fraction during chemotherapy.This study demonstrates that quantitative measures of intra

  10. Resolved complex coastlines and land-sea contrasts in a high-resolution regional climate model

    DEFF Research Database (Denmark)

    Tian, Tian; Boberg, Fredrik; Christensen, Ole BøSsing

    2013-01-01

    system, and (2) examine different ocean responses in coarse and fine grids to atmospheric forcing. The experiments were performed covering the years 1990-2010, both using ERAI lateral boundary conditions. ERAI SSTs generally agree well with satellite SSTs in summer with differences within 1o......C, but the ERAI overestimates the ice extent by 72% in winter due to the coarse resolution in the Baltic Sea. The atmosphere in the Baltic land-sea transition was more sensitive to high-resolution modelled SSTs with a significant improvement in winter, but it also provided a cold bias in summer as a combination...... of errors from both atmospheric and ocean models. Overall, the coupled simulation without observational constraints showed only minor deviations in the air-sea interface in the Baltic coastal region compared to the prescribed simulation, with seasonal mean differences within 2oCin2m air temperatures and 1o...

  11. A novel high-throughput drip-flow system to grow autotrophic biofilms of contrasting diversities

    DEFF Research Database (Denmark)

    Kinnunen, Marta; Dechesne, Arnaud; Albrechtsen, Hans-Jørgen

    . Thus, thicker biofilms are likely to host greater diversity. A system with 40 replicates has been constructed using flow-through polypropylene columns housing a defined number of single-sized glass beads supported by a stainless steel mesh. Biofilms consisting primarily of ammonia oxidizing and nitrite...... are often ill controlled and thus likely to be poorly reproducible. The purpose of this work is to develop a high-throughput continuous-flow system for growing replicate microbial biofilms of varying, but controlled, average thickness and associated community diversity. With these replicate biofilms......, the effect of community composition and diversity on various ecological processes can then be rigorously examined. We hypothesize that the increased loading, resulting in thicker biofilms, will decrease the drift in the community and impose limited environmental filtering by providing more diverse niches...

  12. Applications of Three Dithienylpyrroles-Based Electrochromic Polymers in High-Contrast Electrochromic Devices

    Directory of Open Access Journals (Sweden)

    Yuh-Shan Su

    2017-03-01

    Full Text Available Three dithienylpyrroles (1-(4-(methylthiophenyl-2,5-di(thiophen-2-yl-pyrrole (MPS, 1-(4-methoxyphenyl-2,5-di(thiophen-2-yl-pyrrole (MPO, and 4-(2,5-di(thiophen-2-yl-pyrrol-1-ylbenzonitrile (ANIL were synthesized and their corresponding polydithienylpyrroles (PSNS were electrosynthesized using electrochemical polymerization. Spectroelectrochemical studies indicated that poly(1-(4-(methylthiophenyl-2,5-di(thiophen-2-yl-pyrrole (PMPS film was green, dark green, and brown in the neutral, oxidation, and highly oxidized state, respectively. The incorporation of a MPS unit into the PSNS backbone gave rise to a darker color than those of the MPO and ANIL units in the highly oxidized state. The PMPS film showed higher ΔTmax (54.47% at 940 nm than those of the PMPO (43.87% at 890 nm and PANIL (44.63% at 950 nm films in an ionic liquid solution. Electrochromic devices (ECDs employing PMPS, PMPO, and PANIL as anodic layers and poly(3,4-(2,2-diethypropylenedioxythiophene(PProDOT-Et2 as a cathodic layer were constructed. PMPO/PProDOT-Et2 ECD showed the highest ΔTmax (41.13% and coloration efficiency (674.67 cm2·C−1 at 626 nm, whereas PMPS/PProDOT-Et2 ECD displayed satisfactory ΔTmax (32.51% and coloration efficiency (637.25 cm2·C−1 at 590 nm. Repeated cyclic voltammograms of PMPS/PProDOT-Et2, PMPO/PProDOT-Et2, and PANIL/PProDOT-Et2 ECDs indicated that ECDs had satisfactory redox stability.

  13. Differential responses of seven contrasting species to high light using pigment and chlorophyll a fluorescence

    Directory of Open Access Journals (Sweden)

    Mittal S.

    2011-05-01

    Full Text Available High light intensity may induce severe photodamage to chloroplast and consequently cause decreases in the yield capacity of plants and destruction of pigments, causing an overall yellowing of the foliage. Thus, study related to light adaptation becomes necessary to understand adaptation processes in higher plants on the basis of which they are characterized as full sunlight or shade plants. Chlorophyll can be regarded as an intrinsic fluorescent probe of the photosynthetic system. The ecophysiological parameter related to plant performance and fitness i.e. in-situ chlorophyll fluorescence measurements were determined for different plant species in the medicinal plant garden of Banasthali University, Rajasthan. Miniaturized Pulse Amplitude Modulated Photosynthetic Yield Analyzers are primarily designed for measuring effective quantum yield (ΔF/Fm’ of photosystem II under momentary ambient light in the field. Photosynthetic yield measurements and light-response curves suggested a gradation of sun-adapted to shade-adapted behaviour of these plants in following order Withania somnifera> Catharanthus roseus> Datura stamonium> Vasica minora> Vasica adulta> Rauwolfia serpentina. As indicated by light response curves and pigment analysis, Datura stramonium, Withania somnifera and Catharanthus roseus competed well photosynthetically and are favoured while Rauwolfia serpentina, Vasica minora, Vasica adulta and Plumbago zeylanica were observed to be less competent photosynthetically. These light response curves and resultant cardinal points study gave insight into the ecophysiological characterization of the photosynthetic capacity of the plant and provides highly interesting parameters like electron transport rate, photo-inhibition, photosynthetically active photon flux density and yield on the basis of which light adaptability was screened for seven medicinally important plants.

  14. Therapeutic response assessment of high intensity focused ultrasound therapy for uterine fibroid: Utility of contrast-enhanced ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Xiaodong [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China)]. E-mail: zhouxd@fmmu.edu.cn; Ren Xiaolong [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China)]. E-mail: renxiaolong70@hotmail.com; Zhang Jun [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); He Guangbin [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Zheng Minjuan [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Tian Xue [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Li Li [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Zhu Ting [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Zhang Min [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Wang Lei [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Luo Wen [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China)

    2007-05-15

    Purpose: To assess the utility of contrast-enhanced ultrasonography (ceUS) in the assessment of the therapeutic response to high intensity focused ultrasound (HIFU) ablation in patients with uterine fibroid. Materials and methods: Sixty-four patients with a total of 64 uterine fibroids (mean: 5.3 {+-} 1.2 cm; range: 3.2-8.9 cm) treated with HIFU ablation under the ultrasound guidance were evaluated with ceUS after receiving an intravenous bolus injection of a microbubble contrast agent (SonoVue) within 1 week after intervention. We obtained serial ceUS images during the time period from beginning to 5 min after the initiation of the bolus contrast injection. All of the patients underwent a contrast enhanced MRI (ceMRI) and ultrasound guided needle puncture biopsy within 1 week after HIFU ablation. And as a follow-up, all of the patients underwent US at 1, 3, 6 and 12 months after HIFU treatment. The volume change was observed and compared to pre- and post-HIFU ablation. The results of the ceUS were compared with those of the ceMRI in terms of the presence or absence of residual unablated tumor and pathologic change in the treated lesions. Results: On ceUS, diagnostic accuracy was 100%, while residual unablated tumors were found in three uterine fibroids (4.7%) and failed treatment was found in eight uterine fibroids (12.5%). All the 11 fibroids were subjected to additional HIFU ablation. Of the 58 ablated fibroids without residual tumors on both the ceUS and ceMRI after the HIFU ablation, the volumes of all the fibroids decreased in different degrees during the 1 year follow-up USs. And histologic examinations confirmed findings of necrotic and viable tumor tissue, respectively. Conclusion: CEUS is potentially useful for evaluating the early therapeutic effect of percutaneous HIFU ablation for uterine fibroids.

  15. Grating-based X-ray phase-contrast tomography of atherosclerotic plaque at high photon energies.

    Science.gov (United States)

    Hetterich, Holger; Fill, Sandra; Herzen, Julia; Willner, Marian; Zanette, Irene; Weitkamp, Timm; Rack, Alexander; Schüller, Ulrich; Sadeghi, Mojtaba; Brandl, Richard; Adam-Neumair, Silvia; Reiser, Maximilian; Pfeiffer, Franz; Bamberg, Fabian; Saam, Tobias

    2013-09-01

    Tissue characterization of atherosclerosis by absorption-based imaging methods is limited due to low soft-tissue contrast. Grating-based phase-contrast computed tomography (PC-CT) may become an alternative for plaque assessment if the phase signal can be retrieved at clinically applicable photon energies. The aims of this feasibility study were (i) to characterize arterial vessels at low and high photon energies, (ii) to extract qualitative features and (iii) quantitative phase-contrast Hounsfield units (HU-phase) of plaque components at 53 keV using histopathology as gold standard. Five human carotid artery specimens underwent grating-based PC-CT using synchrotron radiation of either 23 keV or 53 keV and histological work-up. Specimens without advanced atherosclerosis were used to extract signal criteria of vessel layers. Diseased specimens were screened for important plaque components including fibrous tissue (FT), lipid (LIP), necrotic core (NEC), intraplaque hemorrhage (IPH), inflammatory cell infiltration (INF) and calcifications (CA). Qualitative features as well as quantitative HU-phase were analyzed. Thirty-three regions in 6 corresponding PC-CT scans and histology sections were identified. Healthy samples had the same signal characteristics at 23 keV and 53 keV with bright tunica intima and adventitia and dark media. Plaque components showed differences in signal intensity and texture at 53 keV. Quantitative analysis demonstrated the highest HU-phase of soft plaque in dense FT. Less organized LIP, NEC and INF were associated with lower HU-phase values. The highest HU-phase were measured in CA. PC-CT of atherosclerosis is feasible at high, clinically relevant photon energies and provides detailed information about plaque structure including features of high risk vulnerable plaques. Copyright © 2013. Published by Elsevier GmbH.

  16. The role of temporal fine structure information for the low pitch of high-frequency complex tones

    DEFF Research Database (Denmark)

    Santurette, Sébastien; Dau, Torsten

    2011-01-01

    in their waveforms, rather than envelope maxima. Moreover, envelope cues did not take over as the absolute frequency or rank of the lowest component was raised and TFS cues thus became less effective. Instead, the low pitch became less salient. This suggests that complex pitch perception does not rely on envelope......The fused low pitch evoked by complex tones containing only unresolved high-frequency components demonstrates the ability of the human auditory system to extract pitch using a temporal mechanism in the absence of spectral cues. However, the temporal features used by such a mechanism have been...... amplitude fluctuations, or temporal fine structure (TFS), of the conveyed signal can be processed. Using a pitch-matching paradigm, the present study found that the low pitch of inharmonic transposed tones with unresolved components was consistent with the timing between the most prominent TFS maxima...

  17. High-density speckle contrast optical tomography (SCOT) for three dimensional tomographic imaging of the small animal brain.

    Science.gov (United States)

    Dragojević, Tanja; Varma, Hari M; Hollmann, Joseph L; Valdes, Claudia P; Culver, Joseph P; Justicia, Carles; Durduran, Turgut

    2017-06-01

    High-density speckle contrast optical tomography (SCOT) utilizing tens of thousands of source-detector pairs, was developed for in vivo imaging of blood flow in small animals. The reduction in cerebral blood flow (CBF) due to local ischemic stroke in a mouse brain was transcanially imaged and reconstructed in three dimensions. The reconstructed volume was then compared with corresponding magnetic resonance images demonstrating that the volume of reduced CBF agrees with the infarct zone at twenty-four hours. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Strong coupling and high contrast all optical modulation in atomic cladding waveguides

    CERN Document Server

    Stern, Liron; Mazurski, Noa; Levy, Uriel

    2016-01-01

    In recent years we are witnessing a flourish in research aimed to facilitate alkali vapors in guided wave configurations. Owing to the significant reduction in device dimensions, the increase in density of states, the interaction with surfaces and primarily the high intensities carried along the structure, a rich world of light vapor interactions can be studied, and new functionalities, e.g. low power nonlinear light-matter interactions can be achieved. One immense remaining challenge is to study the effects of quantum coherence and shifts in such nano-scale waveguides, characterized by ultra-small mode areas and fast dynamics. Here, we construct a serpentine silicon-nitride wave guide, having atomic vapor as its cladding. The unprecedented mode volume of 5e-13 m^3 supported over a length of 17 mm is used to demonstrate efficient linear and non-linear spectroscopy. Fascinating and important phenomena such as van der Waals shifts, dynamical stark shifts, and coherent effects such as strong coupling (in the for...

  19. High-Contrast Near-Infrared Imaging Polarimetry of the Protoplanetary Disk around RY Tau

    Science.gov (United States)

    Takami, Michihiro; Karr, Jennifer L.; Hashimoto, Jun; Kim, Hyosun; Wisenewski, John; Henning, Thomas; Grady, Carol; Kandori, Ryo; Hodapp, Klaus W.; Kudo, Tomoyuki; hide

    2013-01-01

    We present near-infrared coronagraphic imaging polarimetry of RY Tau. The scattered light in the circumstellar environment was imaged at H-band at a high resolution (approx. 0.05) for the first time, using Subaru-HiCIAO. The observed polarized intensity (PI) distribution shows a butterfly-like distribution of bright emission with an angular scale similar to the disk observed at millimeter wavelengths. This distribution is offset toward the blueshifted jet, indicating the presence of a geometrically thick disk or a remnant envelope, and therefore the earliest stage of the Class II evolutionary phase. We perform comparisons between the observed PI distribution and disk models with: (1) full radiative transfer code, using the spectral energy distribution (SED) to constrain the disk parameters; and (2) monochromatic simulations of scattered light which explore a wide range of parameters space to constrain the disk and dust parameters. We show that these models cannot consistently explain the observed PI distribution, SED, and the viewing angle inferred by millimeter interferometry. We suggest that the scattered light in the near-infrared is associated with an optically thin and geometrically thick layer above the disk surface, with the surface responsible for the infrared SED. Half of the scattered light and thermal radiation in this layer illuminates the disk surface, and this process may significantly affect the thermal structure of the disk.

  20. Enhanced Kα output of Ar and Kr using size optimized cluster target irradiated by high-contrast laser pulses.

    Science.gov (United States)

    Zhang, Lu; Chen, Li-Ming; Yuan, Da-Wei; Yan, Wen-Chao; Wang, Zhao-Hua; Liu, Cheng; Shen, Zhong-Wei; Faenov, Anatoly; Pikuz, Tatiana; Skobelev, Igor; Gasilov, Vladimir; Boldarev, Alexei; Mao, Jing-Yi; Li, Yu-Tong; Dong, Quan-Li; Lu, Xin; Ma, Jing-Long; Wang, Wei-Ming; Sheng, Zheng-Ming; Zhang, Jie

    2011-12-05

    We observed that increasing the clusters size and laser pulse contrast can enhance the X-ray flux emitted by femtosecond-laser-driven-cluster plasma. By focusing a high contrast laser (10(-10)) on large argon clusters, high flux Kα-like X-rays (around 2.96 keV) is generated with a total flux of 2.5 × 10(11) photons/J in 4π and a conversion efficiency of 1.2 × 10-4. In the case of large Kr clusters, the best total flux for L-shell X-rays is 5.3 × 1011 photons/J with a conversion efficiency of 1.3 × 10-4 and, for the Kα X-ray (12.7 keV), it is 8 × 10(8) photons/J with a conversion efficiency of 1.6 × 10-6. Using this X-ray source, a single-shot high-performance X-ray imaging is demonstrated.

  1. Observations of highly sheared turbulence in the H-mode pedestal using Phase Contrast Imaging on DIII-D

    Science.gov (United States)

    Rost, J. C.; Marinoni, A.; Davis, E. M.; Porkolab, M.; Burrell, K. H.

    2017-10-01

    Highly sheared turbulence with short radial correlation lengths has been measured near the top of the H-mode pedestal, in addition to the previously measured highly-sheared turbulence measured in the Er well. Turbulence in regions of large velocity shear is characterized by radial correlation lengths shorter than the poloidal wavelength (L 200 kHz). The phase contrast imaging (PCI) diagnostic on DIII-D is ideally suited to measuring this density turbulence due to the measurement geometry and high frequency bandwidth. Radial localization is achieved by optical filtering, varying the ExB profile, and shifting the plasma position. Reconfiguration of the Er well, such as at the L-H transition or the transition to wide pedestal QH-mode, shows a near-instantaneous change (t < 1 ms) to the sheared turbulence in the Er well ( 1 cm inside the separatrix). In contrast, the sheared turbulence near the top of the pedestal ( 2 cm inside the separatrix) varies over times scales of tens of ms, consistent with pedestal evolution. Work supported by the US Department of Energy under DE-FG02-94ER54235 and DE-FC02-04ER54698.

  2. Contrast Materials

    Science.gov (United States)

    ... safe are contrast materials? Contrast materials are safe drugs; adverse reactions ranging from mild to severe do occur but ... the use of medications such as Beta blockers , NSAIDs , interleukin 2 having received a large amount of ...

  3. Fabrication and characterization of analyzer gratings with high aspect ratios for phase contrast imaging using a Talbot interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Kenntner, Johannes; Altapova, Venera; Grund, Thomas; Pantenburg, Franz Josef; Meiser, Jan; Baumbach, Tilo; Mohr, Juergen [Karlsruhe Institute of Technology (KIT), Institute of Microstructure Technology (IMT), 76021 Karlsruhe (Germany); Karlsruhe Institute of Technology (KIT), Laboratory for Application of Synchrotron Radiation, 76128 Karlsruhe (Germany); Karlsruhe Institute of Technology (KIT), Institute of Microstructure Technology (IMT), 76021 Karlsruhe (Germany); Karlsruhe Institute of Technology (KIT), Laboratory for Application of Synchrotron Radiation, 76128 Karlsruhe (Germany); Karlsruhe Institute of Technology (KIT), Institute of Microstructure Technology (IMT), 76021 Karlsruhe (Germany)

    2012-05-17

    In recent years, X-ray imaging based on the differential phase contrast gained more and more attention to be used in X-ray imaging. Among other techniques like crystal-based diffraction and propagation methods, the grating based Talbot interferometry offers an approach measuring phase modulations of X-rays while passing low absorbing objects. The Talbot interferometer yields for highly efficient X-ray imaging signals for hard X-rays with energies above 10 keV. One factor with high impact on the imaging performance of such grating interferometers is the gratings quality. We introduce a fabrication process allowing both, the fabrication of phase modulating and analyzer gratings with high aspect ratios, up to 100. Structural deviations from the optimal geometry of the gratings are investigated and their influence on the obtained image quality is discussed.

  4. High temporal resolution aberrometry in a 50-eye population and implications for adaptive optics error budget.

    Science.gov (United States)

    Jarosz, Jessica; Mecê, Pedro; Conan, Jean-Marc; Petit, Cyril; Paques, Michel; Meimon, Serge

    2017-04-01

    We formed a database gathering the wavefront aberrations of 50 healthy eyes measured with an original custom-built Shack-Hartmann aberrometer at a temporal frequency of 236 Hz, with 22 lenslets across a 7-mm diameter pupil, for a duration of 20 s. With this database, we draw statistics on the spatial and temporal behavior of the dynamic aberrations of the eye. Dynamic aberrations were studied on a 5-mm diameter pupil and on a 3.4 s sequence between blinks. We noted that, on average, temporal wavefront variance exhibits a n -2 power-law with radial order n and temporal spectra follow a f -1.5 power-law with temporal frequency f . From these statistics, we then extract guidelines for designing an adaptive optics system. For instance, we show the residual wavefront error evolution as a function of the number of corrected modes and of the adaptive optics loop frame rate. In particular, we infer that adaptive optics performance rapidly increases with the loop frequency up to 50 Hz, with gain being more limited at higher rates.

  5. Global assessment of shipping emissions in 2015 on a high spatial and temporal resolution

    Science.gov (United States)

    Johansson, Lasse; Jalkanen, Jukka-Pekka; Kukkonen, Jaakko

    2017-10-01

    We present a comprehensive global shipping emission inventory and the global activities of ships for the year 2015. The emissions were evaluated using the Ship Traffic Emission Assessment Model (STEAM3), which uses Automatic Identification System data to describe the traffic activities of ships. We have improved the model regarding (i) the evaluation of the missing technical specifications of ships, and (ii) the treatment of shipping activities in case of sparse satellite AIS-data. We have developed a model for the collection and processing of available information on the technical specifications, using data assimilation techniques. We have also developed a path regeneration model that constructs, whenever necessary, the detailed geometry of the ship routes. The presented results for fuel consumption were qualitatively in agreement both with those in the 3rd Greenhouse Gas Study of the International Maritime Organisation and those reported by the International Energy Agency. We have also presented high-resolution global spatial distributions of the shipping emissions of NOx, CO2, SO2 and PM2.5. The emissions were also analysed in terms of selected sea areas, ship categories, the sizes of ships and flag states. The emission datasets provided by this study are available upon request; the datasets produced by the model can be utilized as input data for air quality modelling on a global scale, including the full temporal and spatial variation of shipping emissions for the first time. Dispersion modelling using this inventory as input can be used to assess the impacts of various emission abatement scenarios. The emission computation methods presented in this paper could also be used, e.g., to provide annual updates of the global ship emissions.

  6. Examining Spatio-Temporal Intensity-Frequency Variations in Extreme Monsoon Rainfall using High Resolution Data

    Science.gov (United States)

    Devak, M.; Rajendran, V.; C T, D.

    2015-12-01

    The study of extreme events has gained the attention of hydrologists in recent times. Though these events are rare, the effects are catastrophic. It is reported that the frequency of the occurrence of these events has increased in recent decades, and is attributed to the recent revelation of climate change. Numerous studies have pointed out significant changes in extremely heavy precipitation over India, using coarse resolution data. Though there are disagreements in the results and its spatial uniformity, all these studies emphasize the need of fine resolution analysis. Fine resolution analysis is necessary mainly due to the highly heterogeneous characteristics of Indian monsoon, and for the proper employment in flood hazard preparedness and water resources management. The present study aims to analyse the spatio-temporal variation and trends in the intensity and frequency of heavy precipitation during Indian monsoon using 0.25°×0.25° resolution gridded data for a period of 113 years (1901-2013). The exceedance threshold is fixed at 90th percentile of rainfall over 113 years and parameters are defined accordingly. The maximum intensity of each extreme rainfall episode of 30 year moving window has been modelled using Peak Over Threshold based Extreme Value Theory to compute return level (considered for intensity). In addition, the number of such episodes in a particular year has been termed as frequency. Non-parametric Mann-Kendall test has been carried out for both intensity and frequency, to compute the statistical trend. In addition, moving block bootstrap approach has been used to incorporate the serial correlation. The significance of the trend has been evaluated at different significance levels and finally, change in trend over last century has been examined.

  7. Uncoupling High Light Responses from Singlet Oxygen Retrograde Signaling and Spatial-Temporal Systemic Acquired Acclimation.

    Science.gov (United States)

    Carmody, Melanie; Crisp, Peter A; d'Alessandro, Stefano; Ganguly, Diep; Gordon, Matthew; Havaux, Michel; Albrecht-Borth, Verónica; Pogson, Barry J

    2016-07-01

    Distinct ROS signaling pathways initiated by singlet oxygen ((1)O2) or superoxide and hydrogen peroxide have been attributed to either cell death or acclimation, respectively. Recent studies have revealed that more complex antagonistic and synergistic relationships exist within and between these pathways. As specific chloroplastic ROS signals are difficult to study, rapid systemic signaling experiments using localized high light (HL) stress or ROS treatments were used in this study to uncouple signals required for direct HL and ROS perception and distal systemic acquired acclimation (SAA). A qPCR approach was chosen to determine local perception and distal signal reception. Analysis of a thylakoidal ascorbate peroxidase mutant (tapx), the (1)O2-retrograde signaling double mutant (ex1/ex2), and an apoplastic signaling double mutant (rbohD/F) revealed that tAPX and EXECUTER 1 are required for both HL and systemic acclimation stress perception. Apoplastic membrane-localized RBOHs were required for systemic spread of the signal but not for local signal induction in directly stressed tissues. Endogenous ROS treatments revealed a very strong systemic response induced by a localized 1 h induction of (1)O2 using the conditional flu mutant. A qPCR time course of (1)O2 induced systemic marker genes in directly and indirectly connected leaves revealed a direct vascular connection component of both immediate and longer term SAA signaling responses. These results reveal the importance of an EXECUTER-dependent (1)O2 retrograde signal for both local and long distance RBOH-dependent acclimation signaling that is distinct from other HL signaling pathways, and that direct vascular connections have a role in spatial-temporal SAA induction. © 2016 American Society of Plant Biologists. All Rights Reserved.

  8. Mapping temporal changes in connectivity using high-resolution aerial data and object based image analysis

    Science.gov (United States)

    Masselink, Rens; Anders, Niels; Keesstra, Saskia; Seeger, Manuel

    2014-05-01

    Within the field of geomorphology mapping has always been an important tool to interpret spatial and temporal distributions of phenomena and processes at the surface. In the field of connectivity however, although throughout the past decade many articles have been published, there are only very few that go into the mapping of connectivity. This study aimed at developing a new, automated method for mapping connectivity within agricultural catchments. The method, which is a combination of Object-Based Image Analysis (OBIA) and traditional geomorphological field mapping, was applied to two agricultural catchments in Navarre, Spain, both with an area of approximately 2 sq.km. An unmanned aerial vehicle (UAV) was used to take aerial photographs with a resolution of 6 cm, of which a DEM with a 12 cm resolution was created using structure-from-motion photogrammetry. Connectivity was mapped within the study areas using OBIA using a top down method, meaning that connectivity was mapped at different scale levels, starting at the largest scale. Firstly sub-catchments were automatically delineated, after which several characteristics and features that affect connectivity within the sub-catchments were classified, e.g. landuse, landslides, rills, gullies, riparian vegetation, changes in slope, ploughing direction etc. In two consecutive years (2013-2014) photographs were taken and connectivity of both catchments of both years will be compared. Future work will include a quantification of the mapped connectivity (highly connected years vs. low connected years), causes and consequences of these differences in connectivity, comparison to existing connectivity indices and comparison of mapped connectivity in sub-catchments and measured discharge.

  9. High temporal resolution tracing of up-and downward carbon transport in oak trees

    Science.gov (United States)

    Bloemen, Jasper; Ingrisch, Johannes; Bahn, Michael

    2017-04-01

    Carbon (C) allocation defines the flows of C between plant organs and their storage pools and metabolic processes and is therefore considered as an important determinant of forest C budgets and their responses to climate change. In trees, assimilates derived from leaf photosynthesis are transported via the phloem to above- and belowground sink tissues, where partitioning between growth, storage, and respiration occurs. At the same time, root- and aboveground respired CO2 can be dissolved in water and transported in the xylem tissue, thereby representing a secondary C flux of large magnitude. The relative magnitude of both fluxes in a same set of trees and their concurrent role in C allocation remains unclear. In this study, we 13C pulse labeled five year old potted oak (Quercus rubra) trees to investigate both the role of C transport via the phloem and xylem in C allocation. To this end trees were randomly assigned to two 13C labeling experiments: 1) a canopy labeling experiment using transparent canopy chambers and 2) a stem labeling experiment based on the infusion of 13C labeled water in the stem base. We used high-resolution laser-based measurements of the isotopic composition of stem and soil CO2 efflux to monitor both the down-and upward transport of 13C label. Additional tissue samples at stem, canopy and root level were analyzed to validate the assimilation of the label in tree tissues during transport. Overall, after both labeling experiments enrichment was observed in both stem and soil CO2 efflux, showing that the 13C label was removed from both xylem and phloem transport during up- and downward transport, respectively. Higher enrichments of CO2 efflux were observed after stem labeling as compared to canopy labeling, which implies that xylem transport strongly contributes to C lost to the atmosphere. This study is the first to show combined results from tracing of xylem and phloem transport of C for a same set of trees at high temporal resolution using a

  10. Renal insufficiency following contrast media administration trial II (REMEDIAL II): RenalGuard system in high-risk patients for contrast-induced acute kidney injury: rationale and design.

    Science.gov (United States)

    Briguori, Carlo; Visconti, Gabriella; Ricciardelli, Bruno; Condorelli, Gerolama

    2011-04-01

    The combined prophylactic strategy of sodium bicarbonate plus N-acetylsyteine (NAC) seems to be effective in preventing contrast induced acute kidney injury (CI-AKI) in patients at low-to-medium risk. However, in patients at high and very high risk the rate of CI-AKI is still high. In this subset of patients the anticipated advantages of the RenalGuard(tm) System should be investigated. The RenalGuard(tm) System (PLC Medical Systems, Inc., Franklin, MA, USA) is a real-time measurement and real time matched fluid replacement device designed to accommodate the RenalGuard therapy, which is based on the theory that creating and maintaining a high urine output is beneficial by allowing a quick elimination of contrast media, and, therefore, reducing its toxic effects. The REMEDIAL II trial is a randomised, multicentre, investigator-sponsored trial addressing the hypothesis that the RenalGuard System is superior to the prophylaxis with sodium bicarbonate infusion plus NAC in preventing CI-AKI in high and very high risk patients. Consecutive patients with chronic kidney disease (CKD) and at high to very high risk for CI-AKI, referred to our institutions for coronary and/or peripheral procedures, will be randomly assigned to 1) prophylactic administration of sodium bicarbonate plus NAC (control group) and 2) RenalGuard System treatment (RenalGuard group). All enrolled patients must have an estimated glomerular filtration rate ≤ 30 ml/min/1.73 m2 and/or a contrast nephropathy risk score ≥ 11. In all cases iodixanol (an iso-osmolar, non-ionic contrast agent) will be administered. The primary endpoint is an increase of ≥ 0.3 mg/dL in the serum creatinine concentration 48 hours after the procedure. The REMEDIAL II trial will give important answers on how to prevent CI-AKI in high and very high risk patients undergoing contrast media exposure.

  11. Asynchronous single-shot characterization of high-repetition-rate ultrafast waveforms using a time-lens-based temporal magnifier.

    Science.gov (United States)

    Okawachi, Yoshitomo; Salem, Reza; Johnson, Adrea R; Saha, Kasturi; Levy, Jacob S; Lipson, Michal; Gaeta, Alexander L

    2012-12-01

    We demonstrate asynchronous, single-shot characterization of an ultrafast, high-repetition-rate pulse source using a time-lens-based temporal magnifier. We measure a 225 GHz repetition-rate pulse train from a microresonator-based frequency comb. In addition, we show that such a system can be used as a frequency compressor for real-time, high-speed RF spectral characterization.

  12. Searching for fast optical transients by means of a wide-field monitoring observations with high temporal resolution

    Science.gov (United States)

    Beskin, G.; Karpov, S.; Plokhotnichenko, V.; Bondar, S.; Ivanov, E.; Perkov, A.; Greco, G.; Guarnieri, A.; Bartolini, C.

    We discuss the strategy of search for fast optical transients accompanying gamma-ray bursts by means of continuous monitoring of wide sky fields with high temporal resolution. We describe the design, performance and results of our cameras, FAVOR and TORTORA. Also we discuss the perspectives of this strategy and possible design of next-generation equipment for wide-field monitoring which will be able to detect optical transients and to study their color and polarization properties with high time resolution.

  13. 3.0 Tesla high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the pulmonary circulation: initial experience with a 32-channel phased array coil using a high relaxivity contrast agent.

    Science.gov (United States)

    Nael, Kambiz; Fenchel, Michael; Krishnam, Mayil; Finn, J Paul; Laub, Gerhard; Ruehm, Stefan G

    2007-06-01

    To evaluate the technical feasibility of high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with highly accelerated parallel acquisition at 3.0 T using a 32-channel phased array coil, and a high relaxivity contrast agent. Ten adult healthy volunteers (5 men, 5 women, aged 21-66 years) underwent high spatial resolution CE-MRA of the pulmonary circulation. Imaging was performed at 3 T using a 32-channel phase array coil. After intravenous injection of 1 mL of gadobenate dimeglumine (Gd-BOPTA) at 1.5 mL/s, a timing bolus was used to measure the transit time from the arm vein to the main pulmonary artery. Subsequently following intravenous injection of 0.1 mmol/kg of Gd-BOPTA at the same rate, isotropic high spatial resolution data sets (1 x 1 x 1 mm3) CE-MRA of the entire pulmonary circulation were acquired using a fast gradient-recalled echo sequence (TR/TE 3/1.2 milliseconds, FA 18 degrees) and highly accelerated parallel acquisition (GRAPPA x 6) during a 20-second breath hold. The presence of artifact, noise, and image quality of the pulmonary arterial segments were evaluated independently by 2 radiologists. Phantom measurements were performed to assess the signal-to-noise ratio (SNR). Statistical analysis of data was performed by using Wilcoxon rank sum test and 2-sample Student t test. The interobserver variability was tested by kappa coefficient. All studies were of diagnostic quality as determined by both observers. The pulmonary arteries were routinely identified up to fifth-order branches, with definition in the diagnostic range and excellent interobserver agreement (kappa = 0.84, 95% confidence interval 0.77-0.90). Phantom measurements showed significantly lower SNR (P < 0.01) using GRAPPA (17.3 +/- 18.8) compared with measurements without parallel acquisition (58 +/- 49.4). The described 3 T CE-MRA protocol in addition to high T1 relaxivity of Gd-BOPTA provides sufficient SNR to support highly accelerated parallel acquisition

  14. Exploiting Temporal Context in High-Resolution Movement-Related EEG Classification

    Directory of Open Access Journals (Sweden)

    J. Dolezal

    2011-09-01

    Full Text Available The contribution presents an application of a movement-related EEG temporal development classification which improves the classification score of voluntary movements controlled by closely localized regions of the brain. A dynamic Hidden Markov Model-based (HMM classifier specifically designed to capture EEG temporal behavior was used. Surprisingly, HMM classifiers are rarely used for BCI design despite of their advantages. Because of this we also experimented with Learning Vector Quantization, Perceptron, and Support Vector Machine classifiers using a feature space which captures the temporal dynamics of the data. The results presented in this work show that HMM achieves the best performance due to an a priori information on physiological behavior of EEG inserted to the HMM classifier. Feature extraction process and problems with classification were analyzed as well. Classification scores of 66.7% – 94.7% were achieved in our experiments.

  15. High-resolution phase-contrast MRI of aortic and pulmonary blood flow during rest and physical exercise using a MRI compatible bicycle ergometer

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Tim Frederik, E-mail: tim.weber@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Medical Center Heidelberg, INF 110, 69120 Heidelberg (Germany); Department of Radiology, German Cancer Research Center, INF 280, 69120 Heidelberg (Germany); Tengg-Kobligk, Hendrik von, E-mail: hendrik.tengg-kobligk@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Medical Center Heidelberg, INF 110, 69120 Heidelberg (Germany); Department of Radiology, German Cancer Research Center, INF 280, 69120 Heidelberg (Germany); Kopp-Schneider, Annette, E-mail: kopp@dkfz-heidelberg.de [Department of Biostatistics, German Cancer Research Center, INF 280, 69120 Heidelberg (Germany); Ley-Zaporozhan, Julia, E-mail: julia.ley-zaporozhan@med.uni-heidelberg.de [Department of Pediatric Radiology, University Medical Center Heidelberg, INF 430, 69120 Heidelberg (Germany); Kauczor, Hans-Ulrich, E-mail: hans-ulrich.kauczor@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Medical Center Heidelberg, INF 110, 69120 Heidelberg (Germany); Ley, Sebastian, E-mail: sebastian.ley@med.uni.heidelberg.de [Department of Radiology, German Cancer Research Center, INF 280, 69120 Heidelberg (Germany); Department of Pediatric Radiology, University Medical Center Heidelberg, INF 430, 69120 Heidelberg (Germany)

    2011-10-15

    Purpose: To establish high-resolution phase-contrast magnetic resonance imaging (PC-MRI) using a MRI compatible bicycle ergometer to quantify aortic and pulmonary blood flow during resting conditions and exercise. Materials and methods: In 20 healthy volunteers (mean age, 26.8 {+-} 5.0 years) high-resolution PC-MRI (mean temporal resolution, 7.4 {+-} 3.2 ms) was performed in the ascending aorta (AA) and main pulmonary artery (PA) during physical rest and three exercise stages: stage 1, no-load operation; stage 2, heart rate increase 40% compared to rest; stage 3, heart rate increase 80% compared to rest. Flow quantification in AA and PA included flow volume (FV), average velocity (AV), peak velocity (PV) and time to PV (TP). Results: In stage 1 only TP demonstrated a significant change. With progression to stage 2, all parameters altered significantly. Flow measurements during stage 3 evidenced further alterations only of AV and TP regarding both AA and PA. The deviation of the heart rate from the desired target value was significantly higher for stage 3 compared to stage 2, and 15% of the subjects did not reach the desired target heart rate of stage 3 at all. Conclusion: Flow quantification by high-resolution PC-MRI during exercise using a MRI compatible bicycle ergometer is feasible. Medium exercise stages are necessary and sufficient to demonstrate flow alterations in healthy volunteers. PC-MRI ergometry may give insights into aberrant hemodynamic conditions in patients with cardiovascular and pulmonary disease.

  16. A note on variational multiscale methods for high-contrast heterogeneous porous media flows with rough source terms

    KAUST Repository

    Calo, Victor M.

    2011-09-01

    In this short note, we discuss variational multiscale methods for solving porous media flows in high-contrast heterogeneous media with rough source terms. Our objective is to separate, as much as possible, subgrid effects induced by the media properties from those due to heterogeneous source terms. For this reason, enriched coarse spaces designed for high-contrast multiscale problems are used to represent the effects of heterogeneities of the media. Furthermore, rough source terms are captured via auxiliary correction equations that appear in the formulation of variational multiscale methods [23]. These auxiliary equations are localized and one can use additive or multiplicative constructions for the subgrid corrections as discussed in the current paper. Our preliminary numerical results show that one can capture the effects due to both spatial heterogeneities in the coefficients (such as permeability field) and source terms (e.g., due to singular well terms) in one iteration. We test the cases for both smooth source terms and rough source terms and show that with the multiplicative correction, the numerical approximations are more accurate compared to the additive correction. © 2010 Elsevier Ltd.

  17. Piezoelectric Composite Micromachined Multifrequency Transducers for High-Resolution, High-Contrast Ultrasound Imaging for Improved Prostate Cancer Assessment

    Science.gov (United States)

    2016-10-01

    with COMSOL ( COMSOL , Inc., Burlington, MA). After the transducer design and fabrication, the transducer was characterized by measuring electrical... COMSOL simulation; while the aspect ratio of the high frequency layer was designed to be greater than 2 to promote thickness mode operation, which

  18. A method for high-energy, low-dose mammography using edge illumination x-ray phase-contrast imaging

    Science.gov (United States)

    Diemoz, Paul C.; Bravin, Alberto; Sztrókay-Gaul, Anikó; Ruat, Marie; Grandl, Susanne; Mayr, Doris; Auweter, Sigrid; Mittone, Alberto; Brun, Emmanuel; Ponchut, Cyril; Reiser, Maximilian F.; Coan, Paola; Olivo, Alessandro

    2016-12-01

    Since the breast is one of the most radiosensitive organs, mammography is arguably the area where lowering radiation dose is of the uttermost importance. Phase-based x-ray imaging methods can provide opportunities in this sense, since they do not require x-rays to be stopped in tissue for image contrast to be generated. Therefore, x-ray energy can be considerably increased compared to those usually exploited by conventional mammography. In this article we show how a novel, optimized approach can lead to considerable dose reductions. This was achieved by matching the edge-illumination phase method, which reaches very high angular sensitivity also at high x-ray energies, to an appropriate image processing algorithm and to a virtually noise-free detection technology capable of reaching almost 100% efficiency at the same energies. Importantly, while proof-of-concept was obtained at a synchrotron, the method has potential for a translation to conventional sources.

  19. Growth pattern of a common feather moss, Hylocomium splendens, from contrasting water regimes in a high Arctic tundra

    Directory of Open Access Journals (Sweden)

    Takeshi Ueno

    2010-07-01

    Full Text Available Hylocomium splendens, a widespread feather moss, is one of the major plant species found in high-Arctic tundra. It occupies a variety of habitats ranging from exposed dry ground to swampy areas. To clarify the effect of the water regime on the growth pattern of H. splendens, the shoot morphology of H. splendens growing in contrasting water regimes, i.e. hydric, mesic and xeric sites, was investigated using retrospective analyses of growth. The derived growth parameters for H. splendens differed considerably among the sites. The growing period at the hydric, mesic and xeric sites was 1 year, 2 years and 3 years, respectively. The annual increments in segment length and biomass were higher with increasing water availability. These results suggest that water regime has a strong influence on the growth pattern of H. splendens in high-Arctic tundra.

  20. Atmospheric characterization of Proxima b by coupling the SPHERE high-contrast imager to the ESPRESSO spectrograph

    Science.gov (United States)

    Lovis, C.; Snellen, I.; Mouillet, D.; Pepe, F.; Wildi, F.; Astudillo-Defru, N.; Beuzit, J.-L.; Bonfils, X.; Cheetham, A.; Conod, U.; Delfosse, X.; Ehrenreich, D.; Figueira, P.; Forveille, T.; Martins, J. H. C.; Quanz, S. P.; Santos, N. C.; Schmid, H.-M.; Ségransan, D.; Udry, S.

    2017-03-01

    Context. The temperate Earth-mass planet Proxima b is the closest exoplanet to Earth and represents what may be our best ever opportunity to search for life outside the Solar System. Aims: We aim at directly detecting Proxima b and characterizing its atmosphere by spatially resolving the planet and obtaining high-resolution reflected-light spectra. Methods: We propose to develop a coupling interface between the SPHERE high-contrast imager and the new ESPRESSO spectrograph, both installed at ESO VLT. The angular separation of 37 mas between Proxima b and its host star requires the use of visible wavelengths to spatially resolve the planet on a 8.2-m telescope. At an estimated planet-to-star contrast of 10-7 in reflected light, Proxima b is extremely challenging to detect with SPHERE alone. However, the combination of a 103-104 contrast enhancement from SPHERE to the high spectral resolution of ESPRESSO can reveal the planetary spectral features and disentangle them from the stellar ones. Results: We find that significant but realistic upgrades to SPHERE and ESPRESSO would enable a 5σ detection of the planet and yield a measurement of its true mass and albedo in 20-40 nights of telescope time, assuming an Earth-like atmospheric composition. Moreover, it will be possible to probe the O2 bands at 627, 686 and 760 nm, the water vapour band at 717 nm, and the methane band at 715 nm. In particular, a 3.6σ detection of O2 could be made in about 60 nights of telescope time. Those would need to be spread over three years considering optimal observability conditions for the planet. Conclusions: The very existence of Proxima b and the SPHERE-ESPRESSO synergy represent a unique opportunity to detect biosignatures on an exoplanet in the near future. It is also a crucial pathfinder experiment for the development of extremely large telescopes and their instruments, in particular the E-ELT and its high-resolution visible and near-IR spectrograph.

  1. High temporal resolution photography for observing riparian area use and grazing behavior

    Science.gov (United States)

    In 2014, a 2.4 hectare site within the Apache-Sitgreaves National Forest in northeastern Arizona, USA was selected to characterize temporal and spatial patterns of riparian area use. Three consecutive 30, 8, and 46 day time periods representing 1) unrestricted access, 2) prescribed cattle use, and 3...

  2. High-resolution fMRI of Content-sensitive Subsequent Memory Responses in Human Medial Temporal Lobe

    Science.gov (United States)

    Preston, Alison R.; Bornstein, Aaron M.; Hutchinson, J. Benjamin; Gaare, Meghan E.; Glover, Gary H.; Wagner, Anthony D.

    2009-01-01

    The essential role of the medial temporal lobe (MTL) in long-term memory for individual events is well established, yet important questions remain regarding the mnemonic functions of the component structures that constitute the region. Within the hippocampus, recent functional neuroimaging findings suggest that formation of new memories depends on the den tate gyrus and the CA3 field, whereas the contribution of the subiculum may be limited to retrieval. During encoding, it has been further hypothesized that structures within MTL cortex contribute to encoding in a content-sensitive manner, whereas hippocampal structures may contribute to encoding in a more domain-general manner. In the current experiment, high-resolution fMRI techniques were utilized to assess novelty and subsequent memory effects in MTL subregions for two classes of stimuli—faces and scenes. During scanning, participants performed an incidental encoding (target detection) task with novel and repeated faces and scenes. Subsequent recognition memory was indexed for the novel stimuli encountered during scanning. Analyses revealed voxels sensitive to both novel faces and novel scenes in all MTL regions. However, similar percentages of voxels were sensitive to novel faces and scenes in perirhinal cortex, entorhinal cortex, and a combined region comprising the dentate gyrus, CA2, and CA3, whereas parahippocampal cortex, CA1, and subiculum demonstrated greater sensitivity to novel scene stimuli. Paralleling these findings, subsequent memory effects in perirhinal cortex were observed for both faces and scenes, with the magnitude of encoding activation being related to later memory strength, as indexed by a graded response tracking recognition confidence, whereas subsequent memory effects were scene-selective in parahippocampal cortex. Within the hippocampus, encoding activation in the subiculum correlated with subsequent memory for both stimulus classes, with the magnitude of encoding activation varying

  3. Temporal naturalism

    Science.gov (United States)

    Smolin, Lee

    2015-11-01

    Two people may claim both to be naturalists, but have divergent conceptions of basic elements of the natural world which lead them to mean different things when they talk about laws of nature, or states, or the role of mathematics in physics. These disagreements do not much affect the ordinary practice of science which is about small subsystems of the universe, described or explained against a background, idealized to be fixed. But these issues become crucial when we consider including the whole universe within our system, for then there is no fixed background to reference observables to. I argue here that the key issue responsible for divergent versions of naturalism and divergent approaches to cosmology is the conception of time. One version, which I call temporal naturalism, holds that time, in the sense of the succession of present moments, is real, and that laws of nature evolve in that time. This is contrasted with timeless naturalism, which holds that laws are immutable and the present moment and its passage are illusions. I argue that temporal naturalism is empirically more adequate than the alternatives, because it offers testable explanations for puzzles its rivals cannot address, and is likely a better basis for solving major puzzles that presently face cosmology and physics. This essay also addresses the problem of qualia and experience within naturalism and argues that only temporal naturalism can make a place for qualia as intrinsic qualities of matter.

  4. Autonomous agricultural remote sensing systems with high spatial and temporal resolutions

    Science.gov (United States)

    Xiang, Haitao

    In this research, two novel agricultural remote sensing (RS) systems, a Stand-alone Infield Crop Monitor RS System (SICMRS) and an autonomous Unmanned Aerial Vehicles (UAV) based RS system have been studied. A high-resolution digital color and multi-spectral camera was used as the image sensor for the SICMRS system. An artificially intelligent (AI) controller based on artificial neural network (ANN) and an adaptive neuro-fuzzy inference system (ANFIS) was developed. Morrow Plots corn field RS images in the 2004 and 2006 growing seasons were collected by the SICMRS system. The field site contained 8 subplots (9.14 m x 9.14 m) that were planted with corn and three different fertilizer treatments were used among those subplots. The raw RS images were geometrically corrected, resampled to 10cm resolution, removed soil background and calibrated to real reflectance. The RS images from two growing seasons were studied and 10 different vegetation indices were derived from each day's image. The result from the image processing demonstrated that the vegetation indices have temporal effects. To achieve high quality RS data, one has to utilize the right indices and capture the images at the right time in the growing season. Maximum variations among the image data set are within the V6-V10 stages, which indicated that these stages are the best period to identify the spatial variability caused by the nutrient stress in the corn field. The derived vegetation indices were also used to build yield prediction models via the linear regression method. At that point, all of the yield prediction models were evaluated by comparing the R2-value and the best index model from each day's image was picked based on the highest R 2-value. It was shown that the green normalized difference vegetation (GNDVI) based model is more sensitive to yield prediction than other indices-based models. During the VT-R4 stages, the GNDVI based models were able to explain more than 95% potential corn yield

  5. Image Fusion-Based Land Cover Change Detection Using Multi-Temporal High-Resolution Satellite Images

    Directory of Open Access Journals (Sweden)

    Biao Wang

    2017-08-01

    Full Text Available Change detection is usually treated as a problem of explicitly detecting land cover transitions in satellite images obtained at different times, and helps with emergency response and government management. This study presents an unsupervised change detection method based on the image fusion of multi-temporal images. The main objective of this study is to improve the accuracy of unsupervised change detection from high-resolution multi-temporal images. Our method effectively reduces change detection errors, since spatial displacement and spectral differences between multi-temporal images are evaluated. To this end, a total of four cross-fused images are generated with multi-temporal images, and the iteratively reweighted multivariate alteration detection (IR-MAD method—a measure for the spectral distortion of change information—is applied to the fused images. In this experiment, the land cover change maps were extracted using multi-temporal IKONOS-2, WorldView-3, and GF-1 satellite images. The effectiveness of the proposed method compared with other unsupervised change detection methods is demonstrated through experimentation. The proposed method achieved an overall accuracy of 80.51% and 97.87% for cases 1 and 2, respectively. Moreover, the proposed method performed better when differentiating the water area from the vegetation area compared to the existing change detection methods. Although the water area beneath moderate and sparse vegetation canopy was captured, vegetation cover and paved regions of the water body were the main sources of omission error, and commission errors occurred primarily in pixels of mixed land use and along the water body edge. Nevertheless, the proposed method, in conjunction with high-resolution satellite imagery, offers a robust and flexible approach to land cover change mapping that requires no ancillary data for rapid implementation.

  6. Outcomes of corticosteroid prophylaxis for hypersensitivity reactions to low osmolar contrast media in high-risk patients.

    Science.gov (United States)

    Jung, Jae-Woo; Choi, Young Hun; Park, Chang Min; Park, Heung Woo; Cho, Sang-Heon; Kang, Hye-Ryun

    2016-09-01

    Corticosteroid prophylaxis has been widely adopted for the prevention of acute allergic-like reactions to iodinated contrast media, but its use is still controversial because there is no strong evidence supporting its efficacy before administration of nonionic low osmolar contrast media (LOCM). To assess the outcomes of premedication in patients with previous acute allergic-like reactions to LOCM in clinical practice. A retrospective study was performed on 322 high-risk patients who were reexposed to LOCM after premedication composed of antihistamines and/or systemic corticosteroids because of a previous history of acute allergic-like reactions to LOCM. After premedication, 275 patients (85.4%) did not experience any reaction, but 47 patients (14.6%) still experienced a breakthrough reaction. The premedication rate and amount of corticosteroid administered were significantly higher in the nonrecurrence group than in the recurrence group (P = .04 and P = .04, respectively), and a linear trend was observed in the use of corticosteroid premedication and the efficacy of prevention (P for trend = .02). Multivariate binary logistic regression revealed that corticosteroid premedication was effective in preventing recurrence (odds ratio, 0.284; 95% confidence interval, 0.103-0.784). Nonetheless, despite corticosteroid premedication, 3.4% of high-risk patients still experienced moderate to severe reactions, and 14.3% of patients with a severe index reaction again had a severe reaction. Premedication with corticosteroids seems to be helpful in reducing the overall rate of recurrence of acute allergic-like reactions to LOCM in high-risk patients, but patients with severe index reactions are still at risk of developing severe reactions despite corticosteroid premedication. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  7. Transmission electron microscopy of rabbit liver after high-intensity focused ultrasound ablation combined with ultrasound contrast agents.

    Science.gov (United States)

    Jiang, Ying; Tian, Xue; Luo, Wen; Zhou, Xiaodong

    2007-01-01

    The purpose of this study was to observe sequential changes in rabbit liver under transmission electron microscopy after high-intensity focused ultrasound (HIFU) ablation. Thirty rabbits were randomly divided into 2 groups. The livers of rabbits in group A underwent single HIFU ablation; those in group B were given the ultrasound contrast agent Sonovue 0.2 mL/kg before HIFU exposure. Five rabbits from each of the 2 groups were killed at 0 h, 6 d, and 14 d after HIFU ablation. Tissue samples that included targeted and untargeted tissues were observed under transmission electron microscopy. Electron microscopy showed that most of the cell organs in targeted areas of groups A and B disappeared early after HIFU, but the basic cell structure was seen in group A. On the sixth day after HIFU ablation in the 2 groups, all cells in the targeted areas were disrupted and fibrous bands were detected in the rims of targeted areas. In surrounding areas, cell swelling in group B was more severe than in group A, and a greater number of apoptotic bodies were found in group B. The use of an ultrasound contrast agent can enhance the effects of HIFU ablation on the destruction of cell ultrastructure and can enlarge the region of HIFU ablation; this provides experimental evidence for control of HIFU effects.

  8. “House-High Favourites?” – A Contrastive Analysis of Adjective-Noun Collocations in German and English

    Directory of Open Access Journals (Sweden)

    Philippa Maurer-Stroh

    2005-06-01

    Full Text Available Everybody is talking about collocational analyses these days… Despite recent advances in the monolingual sector, the bilingual environment has not yet come under close scrutiny. It is especially the adjective-noun combinations that have become the focus of attention when it comes to contrastive phraseological studies. Adjectives in particular are subject to semantic tailoring and it is important to bear in mind that (predictable interlingual lexical one-to-one occurrence, such as the English starless night and the German sternlose Nacht, is a mere exception rather than the rule in the bilingual adjective-noun state of affairs. Factors that have to be considered are (non- compositionality in contrastive multiword units, like barefaced lie – faustdicke Luge (‘a lie as thick as a man’s fist’, and metaphorical extensions, like haushoher Favorit – hot favourite (*house-high favourite as well as structural differences in the two languages in question, like (at short notice – kurzfristig.

  9. Temporal seizure focus and status epilepticus are associated with high-sensitive troponin I elevation after epileptic seizures.

    Science.gov (United States)

    Chatzikonstantinou, Anastasios; Ebert, Anne D; Hennerici, Michael G

    2015-09-01

    Postictal elevation of high-sensitive troponin I (TNI), a highly specific biomarker for myocardial ischemia, has been reported. We aimed at evaluating its association of high-sensitive troponin I (TNI) with seizure type and focus, as well as vascular risk factors. TNI was measured in 247 patients admitted to our clinic via the emergency room with an acute epileptic seizure. TNI control measurements were performed in 61.5% of cases. All patients underwent electroencephalography and cerebral imaging. Seizure focus - when possible - was determined using results from these examinations as well as clinical data. Of 247 patients, 133 (53.8%) were men, the mean age was 59 ± 18 years. 70 (28.3%) patients had focal and 177 (71.7%) generalized seizures. Status epilepticus was present in 38 cases (15.4%). Mean TNI was 0.05 ± 0.17. TNI was elevated in 27 patients (10.9%). Higher age, status epilepticus and temporal seizure focus were significantly associated with TNI elevation in multivariate analysis. In 21 (13.8%) of the patients with TNI control measurement, TNI was continuously elevated. Higher age and temporal seizure focus were significantly associated with continuously high TNI. Coronary heart disease and vascular risk factors were significantly associated with high TNI only in univariate analysis. No patient had a symptomatic myocardial ischemia. Postictal TNI elevation is relatively common in older patients with status epilepticus or temporal seizure focus. These data support the concept of relevant and possibly dangerous ictal effects on cardiac function especially in temporal lobe seizures. Although the risk of manifest postictal myocardial infarction seems to be very low, selected patients could profit from closer monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Coronary CT angiography using low concentrated contrast media injected with high flow rates: Feasible in clinical practice.

    Science.gov (United States)

    Mihl, Casper; Kok, Madeleine; Wildberger, Joachim E; Altintas, Sibel; Labus, David; Nijssen, Estelle C; Hendriks, Babs M F; Kietselaer, Bas L J H; Das, Marco

    2015-11-01

    Aim of this study was to test the hypothesis that peak injection pressures and image quality using low concentrated contrast media (CM) (240 mg/mL) injected with high flow rates will be comparable to a standard injection protocol (CM: 300 mg/mL) in coronary computed tomographic angiography (CCTA). One hundred consecutive patients were scanned on a 2nd generation dual-source CT scanner. Group 1 (n=50) received prewarmed Iopromide 240 mg/mL at an injection rate of 9 mL/s, followed by a saline chaser. Group 2 (n=50) received the standard injection protocol: prewarmed Iopromide 300 mg/mL; flow rate: 7.2 mL/s. For both protocols, the iodine delivery rate (IDR, 2.16 gI/s) and the total iodine load (22.5 gI) were kept identical. Injection pressure (psi) was continuously monitored by a data acquisition program. Contrast enhancement was measured in the thoracic aorta and all proximal and distal coronary segments. Subjective and objective image quality was evaluated between both groups. No significant differences in peak injection pressures were found between both CM groups (121 ± 5.6 psi vs. 120 ± 5.3 psi, p=0.54). Flow rates of 9 mL/s were safely injected without any complications. No significant differences in contrast-to-noise ratio, signal-to-noise ratio and subjective image quality were found (all p>0.05). No significant differences in attenuation levels were found in the thoracic aorta and all segments of the coronary arteries (all p>0.05). Usage of low iodine concentration CM and injection with high flow rates is feasible. High flow rates (9 mL/s) of Iopromide 240 were safely injected without complications and should not be considered a drawback in clinical practice. No significant differences in peak pressure and image quality were found. This creates a doorway towards applicability of a broad variety in flow rates and IDRs and subsequently more individually tailored injection protocols. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Influence of Game Evolution and the Phase of Competition on Temporal Game Structure in High-Level Table Tennis Tournaments.

    Science.gov (United States)

    Leite, Jorge Vieira de Mello; Barbieri, Fabio Augusto; Miyagi, Willian; Malta, Elvis de Souza; Zagatto, Alessandro Moura

    2017-01-01

    The aims of this study were: a) to investigate the game temporal structure in high-level table tennis competitions; b) to verify the influence of game evolution in international competitions from 2009 to 2012 (World Table Tennis Championships and the Olympic Games) on game temporal structure; c) to compare game temporal structure according to the phase of competition. Comparisons between the three international tournaments demonstrated that rally duration decreased significantly (p < 0.05) during the analyzed period (2009-2012), while the rest time increased (p < 0.05) from 2009 to 2011, but decreased (p < 0.05) from 2011 to 2012. In the competition phase analysis, it was found that rally duration decreased (p < 0.05) in the quarterfinals in relation to the semifinals and finals, while the rest time increased (p < 0.05) from the quarterfinals to semifinals and finals. Based on our findings and previous literature, we concluded that the performance level, game evolution and the competition phase influenced the game temporal structure of table tennis, considering longer rest periods adopted by elite athletes in relation to non-elite athletes, the reduction in rally duration and an increase in rest time over the 2009-2012 period and through the competition phases (quarterfinals to finals).

  12. Influence of Game Evolution and the Phase of Competition on Temporal Game Structure in High-Level Table Tennis Tournaments

    Directory of Open Access Journals (Sweden)

    Leite Jorge Vieira de Mello

    2017-01-01

    Full Text Available The aims of this study were: a to investigate the game temporal structure in high-level table tennis competitions; b to verify the influence of game evolution in international competitions from 2009 to 2012 (World Table Tennis Championships and the Olympic Games on game temporal structure; c to compare game temporal structure according to the phase of competition. Comparisons between the three international tournaments demonstrated that rally duration decreased significantly (p < 0.05 during the analyzed period (2009-2012, while the rest time increased (p < 0.05 from 2009 to 2011, but decreased (p < 0.05 from 2011 to 2012. In the competition phase analysis, it was found that rally duration decreased (p < 0.05 in the quarterfinals in relation to the semifinals and finals, while the rest time increased (p < 0.05 from the quarterfinals to semifinals and finals. Based on our findings and previous literature, we concluded that the performance level, game evolution and the competition phase influenced the game temporal structure of table tennis, considering longer rest periods adopted by elite athletes in relation to non-elite athletes, the reduction in rally duration and an increase in rest time over the 2009-2012 period and through the competition phases (quarterfinals to finals.

  13. Geo-Parcel Based Crop Identification by Integrating High Spatial-Temporal Resolution Imagery from Multi-Source Satellite Data

    Directory of Open Access Journals (Sweden)

    Yingpin Yang

    2017-12-01

    Full Text Available Geo-parcel based crop identification plays an important role in precision agriculture. It meets the needs of refined farmland management. This study presents an improved identification procedure for geo-parcel based crop identification by combining fine-resolution images and multi-source medium-resolution images. GF-2 images with fine spatial resolution of 0.8 m provided agricultural farming plot boundaries, and GF-1 (16 m and Landsat 8 OLI data were used to transform the geo-parcel based enhanced vegetation index (EVI time-series. In this study, we propose a piecewise EVI time-series smoothing method to fit irregular time profiles, especially for crop rotation situations. Global EVI time-series were divided into several temporal segments, from which phenological metrics could be derived. This method was applied to Lixian, where crop rotation was the common practice of growing different types of crops, in the same plot, in sequenced seasons. After collection of phenological features and multi-temporal spectral information, Random Forest (RF was performed to classify crop types, and the overall accuracy was 93.27%. Moreover, an analysis of feature significance showed that phenological features were of greater importance for distinguishing agricultural land cover compared to temporal spectral information. The identification results indicated that the integration of high spatial-temporal resolution imagery is promising for geo-parcel based crop identification and that the newly proposed smoothing method is effective.

  14. Optic disc appearance and retinal temporal vessel arcade geometry in high myopia, as based on follow-up data over 38 years

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Goldschmidt, Ernst

    2010-01-01

    To discuss (i) optic disc appearance and (ii) the retinal course of the temporal vessel arcade in a longitudinal series of high myopia patients followed between the ages of 16 and 54.......To discuss (i) optic disc appearance and (ii) the retinal course of the temporal vessel arcade in a longitudinal series of high myopia patients followed between the ages of 16 and 54....

  15. Bipolar high temporal resolution measurements of snow UV albedo in Sodankylä and Marambio

    Science.gov (United States)

    Meinander, Outi; Kontu, Anna; Asmi, Eija; Sanchez, Ricardo; Mei, Miguel; de Leeuw, Gerrit

    2015-04-01

    In this presentation we will give an overview of our high temporal resolution polar snow UV albedo data from Arctic Sodankylä, and from Marambio, Antarctica. These both are WMO GAW stations with many measurement parameters relevant to the albedo data usage. We will also describe our campaign based polar albedo data (SNORTEX and SOS campaigns), and an important data set of light absorbing impurities (BC) in the Arctic snow. The black carbon (BC) has been estimated to be the second most important human emission after carbon dioxide, in terms of its climate forcing in the present-day atmosphere. The reflectance effect of BC deposited on snow surface is the bigger the smaller the wavelength, i.e. the albedo effect of BC is the biggest at UV. This is also shown in SNICAR-model simulated albedo values. In Sodankylä, our bipolar snow ultraviolet (UV) albedo research started within the International Polar Year (IPY) 2007-2008. In 2007, the continuous Sodankylä snow UV albedo measurements were installed in Sodankylä, in the operational albedo field of the Finnish Meteorological Institute Arctic Research Center (FMI-ARC). These Sodankylä 1-min data during snow time were soon compared with the German Antarctic Neumayer Station UV albedo data, also with the same sensor type. In both data we found an up to 10 % decrease in albedo as a function of time within a day, ranging from 0.77 to 0.67 in Sodankylä and from 0.96 to 0.86 in Neumeyer. Physical explanations to asymmetry were found for cases with high relative humidity and low surface temperature during the previous night, favorable to frost and higher albedo on the next morning; new snow on the previous night; snow melting during day time and refreezing during night. In Marambio, in the beginning of 2013, our new continuous Finnish-Argentinian co-operation snow UV albedo measurements were installed and started as part of a larger continuous meteorological and environmental instrumentation. These new UV radiation data

  16. Ultra-high-field (9.4 T) MRI Analysis of Contrast Agent Transport Across the Blood-Perilymph Barrier and Intrastrial Fluid-Blood Barrier in the Mouse Inner Ear.

    Science.gov (United States)

    Counter, S Allen; Nikkhou-Aski, Sahar; Damberg, Peter; Berglin, Cecilia Engmér; Laurell, Göran

    2017-08-01

    Effective paramagnetic contrast agent for the penetration of the perilymphatic spaces of the scala tympani, scala vestibuli, and scala media of the mouse inner ear can be determined using intravenous injection of various gadolinium (Gd) complexes and ultra-high-field magnetic resonance imaging (MRI) at 9.4 Tesla. A number of contrast agents have been explored in experimental high-field MRI to determine the most effective Gd complex for ideal signal-to-noise ratio and maximal visualization of the in vivo mammalian inner ear in analyzing the temporal and spatial parameters involved in drug penetration of the blood-perilymph barrier and intrastrial fluid-blood barrier in the mouse model using MRI. Gadoteric acid (Dotarem), Gadobutrol (Gadovist), Gadodiamide (Omniscan), Gadopent acid (Magnevist), and Mangafodipir (Teslascan) were administered intravenously using the tail vein of 60 Balb/C mice. High-resolution T1 images of drug penetration were acquired with a horizontal 9.4 T Agilent magnet after intravenously injection. Signal intensity was used as a metric of temporal and spatial parameters of drug delivery and penetration of the perilymphatic and endolymphatic spaces. ANOVA analysis of the area under the curve of intensity enhancement in perilymph revealed a significant difference (p space of the inner ear. Gadoteric acid (Dotarem) demonstrated efficacy as a contrast agent for enhanced visualization of the perilymphatic spaces of the inner ear labyrinthine in the mouse, including the scala tympani and scala vestibuli of the cochlea, and the semicircular canals of the vestibular apparatus. These findings may inform the clinical application of Gd compounds in patients with inner ear fluid disorders and vertigo.

  17. Understanding in-stream temporal coupling of macronutrients based on high-frequency monitoring in groundwater dominated rivers

    Science.gov (United States)

    Bieroza, M. Z.; Heathwaite, A. L.

    2012-04-01

    Developments in high-frequency water quality measurements enable capturing of fine structure of temporal variations in river biogeochemistry. Understanding of the temporal variation in the nutrient source and in-stream processes is critical in restoration of the good ecological and chemical status of river ecosystems. However, to date the in-stream temporal variability of macronutrients captured by high-frequency sampling is poorly understood (Scholefield et al., 2005; Milne et al., 2009; Harris and Heathwaite, 2011). Typically, river water quality monitoring is based on coarse sampling or storm event targeting strategies that miss the low flow water quality dynamics when in-stream processes and chemical-biological interactions may be of the greatest importance. This paper investigates the temporal dynamics and interdependencies between multiple high-frequency (hourly) nutrient and water quality time series collated for the River Leith, a tributary of the River Eden (Cumbria, UK). In-stream nutrients (total phosphorus TP, soluble reactive phosphorus SRP, nitrate nitrogen NO3N) and water quality parameters (turbidity, specific conductivity, pH, temperature, dissolved oxygen, redox potential) were measured by an automated remote mobile lab. A 54 km2 catchment of the River Leith is of mixed geology with Carboniferous limestone overlain by Penrith Sandstone and glacial till deposits. Permeable riverbed deposits create an active groundwater-surface water interface with hyporheic processes potentially exerting control over nutrient cycling. The temporal variation in in-stream nutrients and water quality variables was analysed. Diurnal patterns were observed during low flow conditions for both nutrients and water quality time series. Possible physical and biogeochemical controls on nutrients short-term dynamics were discussed. Antecedent and contemporaneous interdependencies between nutrients, water quality and hydrometric time series were explored in more detail using

  18. High Contrast PET Imaging of GRPR Expression in Prostate Cancer Using Cobalt-Labeled Bombesin Antagonist RM26

    Directory of Open Access Journals (Sweden)

    Bogdan Mitran

    2017-01-01

    Full Text Available High gastrin releasing peptide receptor (GRPR expression is associated with numerous cancers including prostate and breast cancer. The aim of the current study was to develop a 55Co-labeled PET agent based on GRPR antagonist RM26 for visualization of GRPR-expressing tumors. Labeling with 57Co and 55Co, stability, binding specificity, and in vitro and in vivo characteristics of 57Co-NOTA-PEG2-RM26 were studied. NOTA-PEG2-RM26 was successfully radiolabeled with 57Co and 55Co with high yields and demonstrated high stability. The radiopeptide showed retained binding specificity to GRPR in vitro and in vivo. 57Co-NOTA-PEG2-RM26 biodistribution in mice was characterized by rapid clearance of radioactivity from blood and normal non-GRPR-expressing organs and low hepatic uptake. The clearance was predominantly renal with a low degree of radioactivity reabsorption. Tumor-to-blood ratios were approximately 200 (3 h pi and 1000 (24 h pi. The favorable biodistribution of cobalt-labeled NOTA-PEG2-RM26 translated into high contrast preclinical PET/CT (using 55Co and SPECT/CT (using 57Co images of PC-3 xenografts. The initial biological results suggest that 55Co-NOTA-PEG2-RM26 is a promising tracer for PET visualization of GRPR-expressing tumors.

  19. High contrast all-optical diode based on direction-dependent optical bistability within asymmetric ring cavity

    Science.gov (United States)

    Xia, Xiu-Wen; Zhang, Xin-Qin; Xu, Jing-Ping; Yang, Ya-Ping

    2016-08-01

    We propose a simple all-optical diode which is comprised of an asymmetric ring cavity containing a two-level atomic ensemble. Attributed to spatial symmetry breaking of the ring cavity, direction-dependent optical bistability is obtained in a classical bistable system. Therefore, a giant optical non-reciprocity is generated, which guarantees an all-optical diode with a high contrast up to 22 dB. Furthermore, its application as an all-optical logic AND gate is also discussed. Project supported by the National Natural Science Foundation of China (Grant Nos. 11274242, 11474221, and 11574229), the Joint Fund of the National Natural Science Foundation of China and the China Academy of Engineering Physics (Grant No. U1330203), and the National Key Basic Research Special Foundation of China (Grant Nos. 2011CB922203 and 2013CB632701).

  20. Comparison between diffraction contrast tomography and high-energy diffraction microscopy on a slightly deformed aluminium alloy

    Directory of Open Access Journals (Sweden)

    Loïc Renversade

    2016-01-01

    Full Text Available The grain structure of an Al–0.3 wt%Mn alloy deformed to 1% strain was reconstructed using diffraction contrast tomography (DCT and high-energy diffraction microscopy (HEDM. 14 equally spaced HEDM layers were acquired and their exact location within the DCT volume was determined using a generic algorithm minimizing a function of the local disorientations between the two data sets. The microstructures were then compared in terms of the mean crystal orientations and shapes of the grains. The comparison shows that DCT can detect subgrain boundaries with disorientations as low as 1° and that HEDM and DCT grain boundaries are on average 4 µm apart from each other. The results are important for studies targeting the determination of grain volume. For the case of a polycrystal with an average grain size of about 100 µm, a relative deviation of about ≤10% was found between the two techniques.

  1. A multi-wavelength, high-contrast contact radiography system for the study of low-density aerogel foams

    Energy Technology Data Exchange (ETDEWEB)

    Opachich, Y. P., E-mail: opachiyp@nv.doe.gov; Koch, J. A.; Haugh, M. J.; Romano, E.; Lee, J. J.; Huffman, E.; Weber, F. A. [National Security Technologies, LLC, Livermore, California 94550 (United States); Bowers, J. W. [National Security Technologies, LLC, Livermore, California 94550 (United States); University of California at Berkeley, Berkeley, California 94720 (United States); Benedetti, L. R.; Wilson, M.; Prisbrey, S. T.; Wehrenberg, C. E.; Baumann, T. F.; Lenhardt, J. M.; Cook, A.; Arsenlis, A.; Park, H.-S.; Remington, B. A. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)

    2016-07-15

    A multi-wavelength, high contrast contact radiography system has been developed to characterize density variations in ultra-low density aerogel foams. These foams are used to generate a ramped pressure drive in materials strength experiments at the National Ignition Facility and require precision characterization in order to reduce errors in measurements. The system was used to characterize density variations in carbon and silicon based aerogels to ∼10.3% accuracy with ∼30 μm spatial resolution. The system description, performance, and measurement results collected using a 17.8 mg/cc carbon based JX–6 (C{sub 20}H{sub 30}) aerogel are discussed in this manuscript.

  2. Study on differences between high contrast grating reflectors for TM and TE polarizations and their impact on VCSEL designs.

    Science.gov (United States)

    Chung, Il-Sug

    2015-06-29

    A theoretical study of differences in broadband high-index-contrast grating (HCG) reflectors for TM and TE polarizations is presented, covering various grating parameters and properties of HCGs. It is shown that the HCG reflectors for TM polarization (TM HCG reflectors) have much thicker grating thicknesses and smaller grating periods than the TE HCG reflectors. This difference is found to originate from the different boundary conditions met for the electric field of each polarization. Due to this difference, the TM HCG reflectors have much shorter evanescent extension of HCG modes into low-refractive-index media surrounding the HCG. This enables to achieve a very short effective cavity length for VC-SELs, which is essential for ultrahigh speed VCSELs and MEMS-tunable VCSELs. The obtained understandings on polarization dependences will be able to serve as important design guidelines for various HCG-based devices.

  3. Simultaneous generation of ions and high-order harmonics from thin conjugated polymer foil irradiated with ultrahigh contrast laser

    Energy Technology Data Exchange (ETDEWEB)

    Choi, I. W.; Kim, I J.; Pae, K. H.; Nam, K. H.; Lee, C.-L.; Yun, H.; Kim, H. T.; Lee, S. K.; Yu, T. J.; Sung, J. H.; Lee, J. [Advanced Photonics Research Institute, Gwangju Institute of Science and Technology, Gwangju 500-712 (Korea, Republic of); Pirozhkov, A. S.; Ogura, K.; Orimo, S.; Daido, H. [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Kizugawa, Kyoto 619-0215 (Japan)

    2011-10-31

    We report the manufacturing of an (ultra-)thin foil target made of conjugated polymer, poly(9,9'-dioctylfluorene-co-benzothiadiazole) (F8BT), and the simultaneous observation of laser-accelerated ions and second harmonic radiation, when irradiated with ultrahigh-contrast laser pulse at a maximum intensity of 4 x 10{sup 19 }W/cm{sup 2}. Maximum proton energy of 8 MeV is achieved along the target normal direction. Strong second harmonic with over 6% energy ratio compared to fundamental is emitted along the specular direction. Two-dimensional particle-in-cell simulations confirm the simultaneous generation of protons and high-order harmonics, which demonstrates the feasibility of applications requiring particle and radiation sources at once, effectively using the same laser and target.

  4. Maize and sunflower biomass estimation in southwest France using high spatial and temporal resolution remote sensing data

    OpenAIRE

    Claverie, M.; Demarez, V.; Duchemin, B.; Hagolle, O.; Hagolle, Olivier; Ducrot, D.; Marais Sicre, C.; Dejoux, J.-F.; Huc, M.; P. Keravec; Béziat, P.; R. Fieuzal; Ceschia, E.; Dedieu, G.

    2012-01-01

    The recent availability of high spatial and temporal resolution (HSTR) remote sensing data (Formosat-2, and future missions of Ven mu s and Sentinel-2) offers new opportunities for crop monitoring. In this context, we investigated the perspective offered by coupling a simple algorithm for yield estimate (SAFY) with the Formosat-2 data to estimate crop production over large areas. With a limited number of input parameters, the SAFY model enables the simulation of time series of green area inde...

  5. Temporal characterization of plasma cw high-power CO2 laser-matter interaction: contribution to the welding process control

    Science.gov (United States)

    Engel, Thierry; Kane, M.; Fontaine, Joel

    1997-08-01

    During high-power laser welding, gas ionization occurs above the sample. The resulting plasma ignition threshold is related to ionization potential of metallic vapors from the sample, and shielding gases used in the process. In this work, we have characterized the temporal behavior of the radiation emitted by the plasma during laser welding in order to relate the observed signals to the process parameters.

  6. The Moving Group Targets of the SEEDS High-contrast Imaging Survey of Exoplanets and Disks: Results and Observations from the First Three Years

    NARCIS (Netherlands)

    Brandt, T.D.; et al., [Unknown; Thalmann, C.

    2014-01-01

    We present results from the first three years of observations of moving group (MG) targets in the Strategic Exploration of Exoplanets and Disks with Subaru (SEEDS) high-contrast imaging survey of exoplanets and disks using the Subaru telescope. We achieve typical contrasts of ~105 at 1'' and ~106

  7. High-intensity, high-contrast laser pulses generated from the fully diode-pumped Yb:glass laser system POLARIS.

    Science.gov (United States)

    Hornung, Marco; Keppler, Sebastian; Bödefeld, Ragnar; Kessler, Alexander; Liebetrau, Hartmut; Körner, Jörg; Hellwing, Marco; Schorcht, Frank; Jäckel, Oliver; Sävert, Alexander; Polz, Jens; Arunachalam, Ajay Kawshik; Hein, Joachim; Kaluza, Malte C

    2013-03-01

    We report on the first generation of high-contrast, 164 fs duration pulses from the laser system POLARIS reaching focused peak intensities in excess of 2×10(20) W/cm2. To our knowledge, this is the highest peak intensity reported so far that has been achieved with a diode-pumped, solid-state laser. Several passive contrast enhancement techniques have been specially developed and implemented, achieving a relative prepulse intensity smaller than 10(-8) at t=-30 ps before the main pulse. Furthermore a closed-loop adaptive-optics system has been installed. Together with angular chirp compensation, this method has led to a significant reduction of the focal spot size and an increase of the peak intensity.

  8. High-resolution Temporal Representations of Alcohol and Tobacco Behaviors from Social Media Data.

    Science.gov (United States)

    Huang, Tom; Elghafari, Anas; Relia, Kunal; Chunara, Rumi

    2017-11-01

    Understanding tobacco- and alcohol-related behavioral patterns is critical for uncovering risk factors and potentially designing targeted social computing intervention systems. Given that we make choices multiple times per day, hourly and daily patterns are critical for better understanding behaviors. Here, we combine natural language processing, machine learning and time series analyses to assess Twitter activity specifically related to alcohol and tobacco consumption and their sub-daily, daily and weekly cycles. Twitter self-reports of alcohol and tobacco use are compared to other data streams available at similar temporal resolution. We assess if discussion of drinking by inferred underage versus legal age people or discussion of use of different types of tobacco products can be differentiated using these temporal patterns. We find that time and frequency domain representations of behaviors on social media can provide meaningful and unique insights, and we discuss the types of behaviors for which the approach may be most useful.

  9. Evaluation of high resolution spatio-temporal precipitation extremes from a stochastic weather generator

    DEFF Research Database (Denmark)

    Sørup, Hjalte Jomo Danielsen; Christensen, O. B.; Arnbjerg-Nielsen, Karsten

    2017-01-01

    gauges in the model area. The spatiotemporal performance of the model with respect to precipitation extremes is evaluated in the points of a 2x2 km regular grid covering the full model area. The model satisfactorily reproduces the extreme behaviour of the observed precipitation with respect to event...... intensity levels and unconditional spatial correlation when evaluated using an event based ranking approach at point scale and an advanced spatiotemporal coupling of extreme events. Prospectively the model can be used as a tool to evaluate the impact of climate change without relying on precipitation output......Spatio-temporal rainfall is modelled for the North-Eastern part of Zealand (Denmark) using the Spatio-Temporal Neyman-Scott Rectangular Pulses model as implemented in the RainSim software. Hourly precipitation series for fitting the model are obtained from a dense network of tipping bucket rain...

  10. Classification of C3 and C4 Vegetation Types Using MODIS and ETM+ Blended High Spatio-Temporal Resolution Data

    OpenAIRE

    Xiaolong Liu; Yanchen Bo; Jian Zhang; Yaqian He

    2015-01-01

    The distribution of C3 and C4 vegetation plays an important role in the global carbon cycle and climate change. Knowledge of the distribution of C3 and C4 vegetation at a high spatial resolution over local or regional scales helps us to understand their ecological functions and climate dependencies. In this study, we classified C3 and C4 vegetation at a high resolution for spatially heterogeneous landscapes. First, we generated a high spatial and temporal land surface reflectance dataset by b...

  11. Assessment of an Operational System for Crop Type Map Production Using High Temporal and Spatial Resolution Satellite Optical Imagery

    Directory of Open Access Journals (Sweden)

    Jordi Inglada

    2015-09-01

    Full Text Available Crop area extent estimates and crop type maps provide crucial information for agricultural monitoring and management. Remote sensing imagery in general and, more specifically, high temporal and high spatial resolution data as the ones which will be available with upcoming systems, such as Sentinel-2, constitute a major asset for this kind of application. The goal of this paper is to assess to what extent state-of-the-art supervised classification methods can be applied to high resolution multi-temporal optical imagery to produce accurate crop type maps at the global scale. Five concurrent strategies for automatic crop type map production have been selected and benchmarked using SPOT4 (Take5 and Landsat 8 data over 12 test sites spread all over the globe (four in Europe, four in Africa, two in America and two in Asia. This variety of tests sites allows one to draw conclusions applicable to a wide variety of landscapes and crop systems. The results show that a random forest classifier operating on linearly temporally gap-filled images can achieve overall accuracies above 80% for most sites. Only two sites showed low performances: Madagascar due to the presence of fields smaller than the pixel size and Burkina Faso due to a mix of trees and crops in the fields. The approach is based on supervised machine learning techniques, which need in situ data collection for the training step, but the map production is fully automatic.

  12. Quantitative measurement of zinc secretion from pancreatic islets with high temporal resolution using droplet-based microfluidics.

    Science.gov (United States)

    Easley, Christopher J; Rocheleau, Jonathan V; Head, W Steven; Piston, David W

    2009-11-01

    We assayed glucose-stimulated insulin secretion (GSIS) from live, murine islets of Langerhans in microfluidic devices by the downstream formation of aqueous droplets. Zinc ions, which are cosecreted with insulin from beta-cells, were quantitatively measured from single islets with high temporal resolution using a fluorescent indicator, FluoZin-3. Real-time storage of secretions into droplets (volume of 0.470 +/- 0.009 nL) effectively preserves the temporal chemical information, allowing reconstruction of the secretory time record. The use of passive flow control within the device removes the need for syringe pumps, requiring only a single hand-held syringe. Under stimulatory glucose levels (11 mM), bursts of zinc as high as approximately 800 fg islet(-1) min(-1) were measured. Treatment with diazoxide effectively blocked zinc secretion, as expected. High temporal resolution reveals two major classes of oscillations in secreted zinc, with predominate periods at approximately 20-40 s and approximately 5-10 min. The more rapid oscillation periods match closely with those of intraislet calcium oscillations, while the slower oscillations are consistent with insulin pulses typically measured in bulk islet experiments or in the bloodstream. This droplet sampling technique should be widely applicable to time-resolved cellular secretion measurements, either in real-time or for postprocessing.

  13. A comprehensive biomass burning emission inventory with high spatial and temporal resolution in China

    Science.gov (United States)

    Zhou, Ying; Xing, Xiaofan; Lang, Jianlei; Chen, Dongsheng; Cheng, Shuiyuan; Wei, Lin; Wei, Xiao; Liu, Chao

    2017-02-01

    Biomass burning injects many different gases and aerosols into the atmosphere that could have a harmful effect on air quality, climate, and human health. In this study, a comprehensive biomass burning emission inventory including domestic and in-field straw burning, firewood burning, livestock excrement burning, and forest and grassland fires is presented, which was developed for mainland China in 2012 based on county-level activity data, satellite data, and updated source-specific emission factors (EFs). The emission inventory within a 1 × 1 km2 grid was generated using geographical information system (GIS) technology according to source-based spatial surrogates. A range of key information related to emission estimation (e.g. province-specific proportion of domestic and in-field straw burning, detailed firewood burning quantities, uneven temporal distribution coefficient) was obtained from field investigation, systematic combing of the latest research, and regression analysis of statistical data. The established emission inventory includes the major precursors of complex pollution, greenhouse gases, and heavy metal released from biomass burning. The results show that the emissions of SO2, NOx, PM10, PM2.5, NMVOC, NH3, CO, EC, OC, CO2, CH4, and Hg in 2012 are 336.8 Gg, 990.7 Gg, 3728.3 Gg, 3526.7 Gg, 3474.2 Gg, 401.2 Gg, 34 380.4 Gg, 369.7 Gg, 1189.5 Gg, 675 299.0 Gg, 2092.4 Gg, and 4.12 Mg, respectively. Domestic straw burning, in-field straw burning, and firewood burning are identified as the dominant biomass burning sources. The largest contributing source is different for various pollutants. Domestic straw burning is the largest source of biomass burning emissions for all the pollutants considered, except for NH3, EC (firewood), and NOx (in-field straw). Corn, rice, and wheat represent the major crop straws. The combined emission of these three straw types accounts for 80 % of the total straw-burned emissions for each specific pollutant mentioned in this study

  14. Contrastive Lexicology.

    Science.gov (United States)

    Hartmann, R. R. K.

    This paper deals with the relation between etymologically related words in different languages. A survey is made of seven stages in the development of contrastive lexicology. These are: prelinguistic word studies, semantics, lexicography, translation, foreign language learning, bilingualism, and finally contrastive analysis. Concerning contrastive…

  15. Contrasting climate change impact on river flows from high-altitude catchments in the Himalayan and Andes Mountains.

    Science.gov (United States)

    Ragettli, Silvan; Immerzeel, Walter W; Pellicciotti, Francesca

    2016-08-16

    Mountain ranges are the world's natural water towers and provide water resources for millions of people. However, their hydrological balance and possible future changes in river flow remain poorly understood because of high meteorological variability, physical inaccessibility, and the complex interplay between climate, cryosphere, and hydrological processes. Here, we use a state-of-the art glacio-hydrological model informed by data from high-altitude observations and the latest climate change scenarios to quantify the climate change impact on water resources of two contrasting catchments vulnerable to changes in the cryosphere. The two study catchments are located in the Central Andes of Chile and in the Nepalese Himalaya in close vicinity of densely populated areas. Although both sites reveal a strong decrease in glacier area, they show a remarkably different hydrological response to projected climate change. In the Juncal catchment in Chile, runoff is likely to sharply decrease in the future and the runoff seasonality is sensitive to projected climatic changes. In the Langtang catchment in Nepal, future water availability is on the rise for decades to come with limited shifts between seasons. Owing to the high spatiotemporal resolution of the simulations and process complexity included in the modeling, the response times and the mechanisms underlying the variations in glacier area and river flow can be well constrained. The projections indicate that climate change adaptation in Central Chile should focus on dealing with a reduction in water availability, whereas in Nepal preparedness for flood extremes should be the policy priority.

  16. On-sky Closed-loop Correction of Atmospheric Dispersion for High-contrast Coronagraphy and Astrometry

    Science.gov (United States)

    Pathak, P.; Guyon, O.; Jovanovic, N.; Lozi, J.; Martinache, F.; Minowa, Y.; Kudo, T.; Kotani, T.; Takami, H.

    2018-02-01

    Adaptive optic (AO) systems delivering high levels of wavefront correction are now common at observatories. One of the main limitations to image quality after wavefront correction comes from atmospheric refraction. An atmospheric dispersion compensator (ADC) is employed to correct for atmospheric refraction. The correction is applied based on a look-up table consisting of dispersion values as a function of telescope elevation angle. The look-up table-based correction of atmospheric dispersion results in imperfect compensation leading to the presence of residual dispersion in the point spread function (PSF) and is insufficient when sub-milliarcsecond precision is required. The presence of residual dispersion can limit the achievable contrast while employing high-performance coronagraphs or can compromise high-precision astrometric measurements. In this paper, we present the first on-sky closed-loop correction of atmospheric dispersion by directly using science path images. The concept behind the measurement of dispersion utilizes the chromatic scaling of focal plane speckles. An adaptive speckle grid generated with a deformable mirror (DM) that has a sufficiently large number of actuators is used to accurately measure the residual dispersion and subsequently correct it by driving the ADC. We have demonstrated with the Subaru Coronagraphic Extreme AO (SCExAO) system on-sky closed-loop correction of residual dispersion to direct detection of habitable exoplanets with upcoming extremely large telescopes (ELTs) and also provide a diagnostic tool to test the performance of instruments which require sub-milliarcsecond correction.

  17. Quantification of hepatic blood flow using a high-resolution phase-contrast MRI sequence with compressed sensing acceleration.

    Science.gov (United States)

    Dyvorne, Hadrien A; Knight-Greenfield, Ashley; Besa, Cecilia; Cooper, Nancy; Garcia-Flores, Julio; Schiano, Thomas D; Markl, Michael; Taouli, Bachir

    2015-03-01

    OBJECTIVE. The objective of our study was to evaluate the performance of a high-spatial-resolution 2D phase-contrast (PC) MRI technique accelerated with compressed sensing for portal vein (PV) and hepatic artery (HA) flow quantification in comparison with a standard PC MRI sequence. SUBJECTS AND METHODS. In this prospective study, two PC MRI sequences were compared, one with parallel imaging acceleration and low spatial resolution (generalized autocalibrating partial parallel acquisition [GRAPPA]) and one with compressed sensing acceleration and high spatial resolution (sparse). Seventy-six patients were assessed, including 37 patients with cirrhosis. Two observers evaluated PC image quality. Quantitative analyses yielded a mean velocity, flow, and vessel area for the PV and HA and an arterial fraction. The PC techniques were compared using the paired Wilcoxon test and Bland-Altman statistics. The sensitivity of the flow parameters to the severity of cirrhosis was also assessed. RESULTS. Vessel delineation was significantly improved using the PC sparse sequence (p spatial-resolution highly accelerated compressed sensing technique (PC sparse) allows total hepatic blood flow measurements obtained in 1 breath-hold, provides improved delineation of the hepatic vessels compared with a standard PC MRI sequence (GRAPPA), and can potentially be used for the noninvasive assessment of liver cirrhosis.

  18. MR imaging in recurrent pain after back surgery. A comparative study using standard and high doses of gadolinium contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Aakeson, P. [Univ. Hospital, Lund (Sweden). Dep