WorldWideScience

Sample records for high quality standard

  1. Air Quality Standards for Particulate Matter (PM) at high altitude cities

    International Nuclear Information System (INIS)

    Bravo Alvarez, H.; Sosa Echeverria, R.; Sanchez Alvarez, P.; Krupa, S.

    2013-01-01

    The Air Quality Standards for Particulate Matter (PM) at high altitude urban areas in different countries, must consider the pressure and temperature due to the effect that these parameters have on the breath volume. This paper shows the importance to correct Air Quality Standards for PM considering pressure and temperature at different altitudes. Specific factors were suggested to convert the information concerning PM, from local to standard conditions, and adjust the Air Quality Standards for different high altitudes cities. The correction factors ranged from: 1.03 for Santiago de Chile to 1.47 for El Alto Bolivia. Other cities in this study include: Mexico City, México; La Paz, Bolivia; Bogota, Cali and Medellin, Colombia; Quito, Ecuador and Cuzco, Peru. If these corrections are not considered, the atmospheric concentrations will be underestimated. - Highlights: ► AQS for particulate matter concentrations adjusted by pressure and temperature. ► Particulate matter concentrations can be underestimated in high altitude Cities. ► Particulate matter concentrations must be compared under the same conditions. - In order to compare high altitude atmospheric PM concentrations with AQS, one must consider T and P of the sampling site.

  2. Learning Disabilities and Achieving High-Quality Education Standards

    Science.gov (United States)

    Gartland, Debi; Strosnider, Roberta

    2017-01-01

    This is an official document of the National Joint Committee on Learning Disabilities (NJCLD), of which Council for Learning Disabilities is a long-standing, active member. With this position paper, NJCLD advocates for the implementation of high-quality education standards (HQES) for students with learning disabilities (LD) and outlines the…

  3. Quality of semantic standards

    NARCIS (Netherlands)

    Folmer, Erwin Johan Albert

    2012-01-01

    Little scientific literature addresses the issue of quality of semantic standards, albeit a problem with high economic and social impact. Our problem survey, including 34 semantic Standard Setting Organizations (SSOs), gives evidence that quality of standards can be improved, but for improvement a

  4. Clinical quality standards for radiotherapy

    Science.gov (United States)

    2012-01-01

    Aim of the study The technological progress that is currently being witnessed in the areas of diagnostic imaging, treatment planning systems and therapeutic equipment has caused radiotherapy to become a high-tech and interdisciplinary domain involving staff of various backgrounds. This allows steady improvement in therapy results, but at the same time makes the diagnostic, imaging and therapeutic processes more complex and complicated, requiring every stage of those processes to be planned, organized, controlled and improved so as to assure high quality of services provided. The aim of this paper is to present clinical quality standards for radiotherapy as developed by the author. Material and methods In order to develop the quality standards, a comparative analysis was performed between European and Polish legal acts adopted in the period of 1980-2006 and the universal industrial ISO 9001:2008 standard, defining requirements for quality management systems, and relevant articles published in 1984-2009 were reviewed, including applicable guidelines and recommendations of American, international, European and Polish bodies, such as the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy & Oncology (ESTRO), the International Atomic Energy Agency (IAEA), and the Organisation of European Cancer Institutes (OECI) on quality assurance and management in radiotherapy. Results As a result, 352 quality standards for radiotherapy were developed and categorized into the following three groups: 1 – organizational standards; 2 – physico-technical standards and 3 – clinical standards. Conclusion Proposed clinical quality standards for radiotherapy can be used by any institution using ionizing radiation for medical purposes. However, standards are of value only if they are implemented, reviewed, audited and improved, and if there is a clear mechanism in place to monitor and address failure to meet agreed standards. PMID:23788854

  5. The Measurement of Quality of Semantic Standards : the Application of a Quality Model on the SETU standard for eGovernment

    NARCIS (Netherlands)

    Folmer, Erwin; van Bekkum, Michael; Oude Luttighuis, Paul; van Hillegersberg, Jos

    2011-01-01

    eGovernment interoperability should be dealt with using high-quality standards. A quality model for standards is presented based on knowledge from the software engineering domain. In the tradition of action research the model is used on the SETU standard, a standard that is mandatory in the public

  6. British standard (BS) 5750--quality assurance?

    Science.gov (United States)

    Pratt, D J

    1995-04-01

    BS5750 is the British Standard on "Quality Systems". Its equivalent in European Standards is EN29000 and in the International Standards Organisation ISO9000. This paper points out that these standards lay down formalised procedures and require documentation but do not ipso facto lead to quality assurance. The author points to the Japanese post-war industrial success as being an example of Total Quality Management within the framework provided by the philosophy of Dr. W. Edwards Deming (1988 and 1993). This philosophy on the management of "systems" to provide high quality products and services is briefly outlined. The author argues that improvement in prosthetic and orthotic services will not be reached through implementation of BS5750 but rather through radical rethinking and the adoption and application of the Deming philosophy.

  7. GENERIC QUALITY STANDARDS VS. SPECIFIC QUALITY STANDARDS: THE CASE OF HIGHER EDUCATION

    Directory of Open Access Journals (Sweden)

    Laila El Abbadi

    2011-06-01

    Full Text Available Quality as a new requirement for the field of higher education leads institutions to seek to satisfy generic or specific quality standards imposed directly or indirectly by its customers. The aim of this study is to compare between ISO9001, as a generic quality standard, and the Code of Practice of the Quality Assurance Agency for Higher Education (QAA, as a specific quality standard. A correlation matrix is drawn and correlation rates are calculated to show similarities and differences between them. This paper shows, first, that ISO9001 and QAA Code of Practice are compatible. Second, implementing a quality management system in accordance with ISO9001 requirements can constitute an adequate framework for the application of the QAA Code of Practice requirements. Third, to make the ISO9001 requirements closer to a specific quality standard in the field of higher education, it is recommended to complete these standards by specific requirements to the field of higher education.

  8. Quality Assurance Standards for Symptomatic Breast Disease Services

    OpenAIRE

    Department of Health (Ireland)

    2007-01-01

    Quality Assurance Standards for Symptomatic Breast Disease Services People in Ireland have a right to expect that medical care be of good quality. They expect that standards of care are consistently high. They expect that access to care is easy, speedy, effective and efficient. Society expects quality of care to measure up to international norms of good practice. Such assurance can be given by auditing the quality of activity. Click here to download PDF 606kb

  9. NAGC Pre-K-Grade 12 Gifted Education Programming Standards: A Guide to Planning and Implementing High-Quality Services

    Science.gov (United States)

    Johnsen, Susan K., Ed.

    2012-01-01

    The new Pre-K-Grade 12 Gifted Education Programming Standards should be part of every school district's repertoire of standards to ensure that the learning needs of advanced students are being met. "NAGC Pre-K-Grade 12 Gifted Education Programming Standards: A Guide to Planning and Implementing High-Quality Services" details six standards that…

  10. New Quality Standards of Testing Idlers for Highly Effective Belt Conveyors

    Science.gov (United States)

    Król, Robert; Gladysiewicz, Lech; Kaszuba, Damian; Kisielewski, Waldemar

    2017-12-01

    The paper presents result of research and analyses carried out into the belt conveyors idlers’ rotational resistance which is one of the key factor indicating the quality of idlers. Moreover, idlers’ rotational resistance is important factor in total resistance to motion of belt conveyor. The evaluation of the technical condition of belt conveyor idlers is carried out in accordance with actual national and international standards which determine the methodology of measurements and acceptable values of measured idlers’ parameters. Requirements defined by the standards, which determine the suitability of idlers to a specific application, despite the development of knowledge on idlers and quality of presently manufactured idlers maintain the same level of parameters values over long periods of time. Nowadays the need to implement new, efficient and economically justified solution for belt conveyor transportation systems characterized by long routes and energy-efficiency is often discussed as one of goals in belt conveyors’ future. One of the basic conditions for achieving this goal is to use only carefully selected idlers with low rotational resistance under the full range of operational loads and high durability. Due to this it is necessary to develop new guidelines for evaluation of the technical condition of belt conveyor idlers in accordance with actual standards and perfecting of existing and development of new methods of idlers testing. The changes in particular should concern updating of values of parameters used for evaluation of the technical condition of belt conveyor idlers in relation to belt conveyors’ operational challenges and growing demands in terms of belt conveyors’ energy efficiency.

  11. Standards and quality

    CERN Document Server

    El-Tawil, Anwar

    2015-01-01

    The book brings together a number of subjects of prime importance for any practicing engineer and, students of engineering. The book explains the concepts and functions of voluntary standards, mandatory technical regulations, conformity assessment (testing and measurement of products), certification, quality and quality management systems as well as other management systems such as environmental, social responsibility and food safety management systems.The book also gives a comprehensive description of the role of metrology systems that underpin conformity assessment. A description is given of typical national systems of standards, quality and metrology and how they relate directly or through regional structures to international systems. The book also covers the relation between standards and trade and explains the context and stipulations of the Technical Barriers to Trade Agreement of the World Trade Organization (WTO).

  12. Requirements of quality standards

    International Nuclear Information System (INIS)

    Mueller, J.

    1977-01-01

    The lecture traces the development of nuclear standards, codes, and Federal regulations on quality assurance (QA) for nuclear power plants and associated facilities. The technical evolution of the last twelve years, especially in the area of nuclear technology, led to different activities and regulatory initiatives, and the present result is: several nations have their own homemade standards. The lecture discusses the former and especially current activities in standard development, and gives a description of the requirements of QA-standards used in USA and Europe, especially Western Germany. Furthermore the lecture attempts to give a comparison and an evaluation of the international quality standards from the author's viewpoint. Finally the lecture presents an outlook for the future international implications of QA-standards. There is an urgent need within the nuclear industry for simplification and standardization of QA-standards. The relationship between the various standards, and the applicability of the standards need clarification and a better transparancy. To point out these problems is the purpose of the lecture. (orig.) [de

  13. Quality standards for bone conduction implants.

    Science.gov (United States)

    Gavilan, Javier; Adunka, Oliver; Agrawal, Sumit; Atlas, Marcus; Baumgartner, Wolf-Dieter; Brill, Stefan; Bruce, Iain; Buchman, Craig; Caversaccio, Marco; De Bodt, Marc T; Dillon, Meg; Godey, Benoit; Green, Kevin; Gstoettner, Wolfgang; Hagen, Rudolf; Hagr, Abdulrahman; Han, Demin; Kameswaran, Mohan; Karltorp, Eva; Kompis, Martin; Kuzovkov, Vlad; Lassaletta, Luis; Li, Yongxin; Lorens, Artur; Martin, Jane; Manoj, Manikoth; Mertens, Griet; Mlynski, Robert; Mueller, Joachim; O'Driscoll, Martin; Parnes, Lorne; Pulibalathingal, Sasidharan; Radeloff, Andreas; Raine, Christopher H; Rajan, Gunesh; Rajeswaran, Ranjith; Schmutzhard, Joachim; Skarzynski, Henryk; Skarzynski, Piotr; Sprinzl, Georg; Staecker, Hinrich; Stephan, Kurt; Sugarova, Serafima; Tavora, Dayse; Usami, Shin-Ichi; Yanov, Yuri; Zernotti, Mario; Zorowka, Patrick; de Heyning, Paul Van

    2015-01-01

    Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.

  14. Web 2.0-based crowdsourcing for high-quality gold standard development in clinical natural language processing.

    Science.gov (United States)

    Zhai, Haijun; Lingren, Todd; Deleger, Louise; Li, Qi; Kaiser, Megan; Stoutenborough, Laura; Solti, Imre

    2013-04-02

    A high-quality gold standard is vital for supervised, machine learning-based, clinical natural language processing (NLP) systems. In clinical NLP projects, expert annotators traditionally create the gold standard. However, traditional annotation is expensive and time-consuming. To reduce the cost of annotation, general NLP projects have turned to crowdsourcing based on Web 2.0 technology, which involves submitting smaller subtasks to a coordinated marketplace of workers on the Internet. Many studies have been conducted in the area of crowdsourcing, but only a few have focused on tasks in the general NLP field and only a handful in the biomedical domain, usually based upon very small pilot sample sizes. In addition, the quality of the crowdsourced biomedical NLP corpora were never exceptional when compared to traditionally-developed gold standards. The previously reported results on medical named entity annotation task showed a 0.68 F-measure based agreement between crowdsourced and traditionally-developed corpora. Building upon previous work from the general crowdsourcing research, this study investigated the usability of crowdsourcing in the clinical NLP domain with special emphasis on achieving high agreement between crowdsourced and traditionally-developed corpora. To build the gold standard for evaluating the crowdsourcing workers' performance, 1042 clinical trial announcements (CTAs) from the ClinicalTrials.gov website were randomly selected and double annotated for medication names, medication types, and linked attributes. For the experiments, we used CrowdFlower, an Amazon Mechanical Turk-based crowdsourcing platform. We calculated sensitivity, precision, and F-measure to evaluate the quality of the crowd's work and tested the statistical significance (Pcrowdsourced and traditionally-developed annotations. The agreement between the crowd's annotations and the traditionally-generated corpora was high for: (1) annotations (0.87, F-measure for medication names

  15. 40 CFR 130.3 - Water quality standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Water quality standards. 130.3 Section... QUALITY PLANNING AND MANAGEMENT § 130.3 Water quality standards. A water quality standard (WQS) defines the water quality goals of a water body, or portion thereof, by designating the use or uses to be made...

  16. Quality model for semantic IS standards

    NARCIS (Netherlands)

    Folmer, Erwin Johan Albert

    2011-01-01

    Semantic IS (Information Systems) standards are essential for achieving interoperability between organizations. However a recent survey suggests that not the full benefits of standards are achieved, due to the quality issues. This paper presents a quality model for semantic IS standards, that should

  17. STANDARDIZING QUALITY ASSESSMENT OF FUSED REMOTELY SENSED IMAGES

    Directory of Open Access Journals (Sweden)

    C. Pohl

    2017-09-01

    Full Text Available The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  18. Standardizing Quality Assessment of Fused Remotely Sensed Images

    Science.gov (United States)

    Pohl, C.; Moellmann, J.; Fries, K.

    2017-09-01

    The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment) in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS) to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR) and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  19. National Water Quality Standards Database (NWQSD)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The National Water Quality Standards Database (WQSDB) provides access to EPA and state water quality standards (WQS) information in text, tables, and maps. This data...

  20. [Study on seed quality test and quality standard of Lonicera macranthoides].

    Science.gov (United States)

    Zhang, Ying; Xu, Jin; Li, Long-Yun; Cui, Guang-Lin; She, Yue-Hui

    2016-04-01

    Referring to the rules for agricultural seed testing (GB/T 3543-1995) issued by China, the test of sampling, purity, thousand seed weight, moisture, viability, relative conductivity and germination rate had been studied for seed quality test methods of Lonicera macranthoides. The seed quality from 38 different collection areas was measured to establish quality classification standard by K-means clustering. The results showed that at least 7.5 g seeds should be sampled, and passed 20-mesh sieve for purity analysis.The 500-seed method used to measure thousand seed weight. The moisture was determined by crushed seeds dried in high temperature (130±2) ℃ for 3 h.The viability determined by 25 ℃ 0.1% TTC stained 5h in dark. 1.0 g seeds soaked in 50 ml ultra pure water in 25 ℃ for 12 hours to determine the relative conductivity. The seed by 4 ℃stratification for 80 days were cultured on paper at 15 ℃. Quality of the seeds from different areas was divided into three grades. The primary seed quality classification standard was established.The I grade and II grade were recommend use in production. Copyright© by the Chinese Pharmaceutical Association.

  1. Standardized quality in MOOC based learning

    Directory of Open Access Journals (Sweden)

    Maiorescu Irina

    2015-04-01

    Full Text Available Quality in the field of e-learning and, particularly, in the field of MOOC( Massive Open Online Courses, is a topic of growing importance in both academic institutions and in the private sector as it has generally been proved that quality management can contribute to improving the performance of organizations, regardless of their object of activity. Despite the fact that there are standards relating to quality management in a general manner, professionals, academic staff, specialists and bodies felt the need for having a standardized approach of the quality in the sector of e-learning. Therefore, in the last years, in different countries quality guidelines have been developed and used for e-Learning or distance education (for example the ASTD criteria for e- Learning, the BLA Quality Mark, Quality Platform Learning by D-ELAN etc.. The current paper aims to give insights to this new form of online education provided by MOOC platforms using the specific quality standard approach.

  2. Life quality and living standards in big cities under conditions of high-rise construction development

    Science.gov (United States)

    Avdeeva, Elena; Averina, Tatiana; Kochetova, Larisa

    2018-03-01

    Modern urbanization processes occurring on a global scale inevitably lead to an increase in population density in large cities. People assess the state of life quality and living standards of megalopolises under conditions of high-rise construction development ambiguously. Using SWOT analysis, the authors distinguished positive and negative aspects of high-rise construction, highlighted threats to its development and its opportunities. The article considers the model of development of the city's industry and infrastructure, which enables determining the optimal volume of production by sectors and branches of city economy in order to increase its innovative, production and economic potential and business activity.

  3. British Thoracic Society quality standards for the investigation and management of pulmonary nodules

    Science.gov (United States)

    Baldwin, David; Callister, Matthew; Akram, Ahsan; Cane, Paul; Draffan, Jeanette; Franks, Kevin; Gleeson, Fergus; Graham, Richard; Malhotra, Puneet; Pearson, Philip; Subesinghe, Manil; Waller, David; Woolhouse, Ian

    2018-01-01

    Introduction The purpose of the quality standards document is to provide healthcare professionals, commissioners, service providers and patients with a guide to standards of care that should be met for the investigation and management of pulmonary nodules in the UK, together with measurable markers of good practice. Methods Development of British Thoracic Society (BTS) Quality Standards follows the BTS process of quality standard production based on the National Institute for Health and Care Excellence process manual for the development of quality standards. Results 7 quality statements have been developed, each describing a key marker of high-quality, cost-effective care for the investigation and management of pulmonary nodules, and each statement is supported by quality measures that aim to improve the structure, process and outcomes of healthcare. Discussion BTS Quality Standards for the investigation and management of pulmonary nodules form a key part of the range of supporting materials that the Society produces to assist in the dissemination and implementation of guideline recommendations. PMID:29682290

  4. National standards for high school psychology curricula.

    Science.gov (United States)

    2013-01-01

    The National Standards for High School Psychology Curricula attempts to represent current knowledge in the field of psychology in developmentally appropriate ways. Psychology is a popular high school course, one that can introduce students to scientific ideas and engage students in the learning process. However, it is difficult for even the best of teachers to present all of psychology in a single course for students who begin with virtually no formal knowledge of psychology. The standards presented here constitute the first of two reports in this issue of the American Psychologist (January 2013) representing recent American Psychological Association (APA) policies that support high-quality instruction in the teaching of high school psychology. These standards provide curricular benchmarks for student learning in the high school course.

  5. Assessing Quality of Data Standards: Framework and Illustration Using XBRL GAAP Taxonomy

    Science.gov (United States)

    Zhu, Hongwei; Wu, Harris

    The primary purpose of data standards or metadata schemas is to improve the interoperability of data created by multiple standard users. Given the high cost of developing data standards, it is desirable to assess the quality of data standards. We develop a set of metrics and a framework for assessing data standard quality. The metrics include completeness and relevancy. Standard quality can also be indirectly measured by assessing interoperability of data instances. We evaluate the framework using data from the financial sector: the XBRL (eXtensible Business Reporting Language) GAAP (Generally Accepted Accounting Principles) taxonomy and US Securities and Exchange Commission (SEC) filings produced using the taxonomy by approximately 500 companies. The results show that the framework is useful and effective. Our analysis also reveals quality issues of the GAAP taxonomy and provides useful feedback to taxonomy users. The SEC has mandated that all publicly listed companies must submit their filings using XBRL. Our findings are timely and have practical implications that will ultimately help improve the quality of financial data.

  6. 78 FR 54517 - Water Quality Standards Regulatory Clarifications

    Science.gov (United States)

    2013-09-04

    ... 131 Water Quality Standards Regulatory Clarifications; Proposed Rule #0;#0;Federal Register / Vol. 78... AGENCY 40 CFR Part 131 [EPA-HQ-OW-2010-0606; FRL-9839-7] RIN 2040-AF 16 Water Quality Standards... Environmental Protection Agency (EPA) is proposing changes to the federal water quality standards (WQS...

  7. Study on Quality Standard of Processed Curcuma Longa Radix

    Directory of Open Access Journals (Sweden)

    Zhimin Chen

    2017-01-01

    Full Text Available To control the quality of Curcuma Longa Radix by establishing quality standards, this paper increased the contents of extract and volatile oil determination. Meanwhile, the curcumin was selected as the internal marker, and the relative correlation factors (RCFs of demethoxycurcumin and bisdemethoxycurcumin were established by high performance liquid chromatography (HPLC. The contents of multicomponents were calculated based on their RCFs. The rationality and feasibility of the methods were evaluated by comparison of the quantitative results between external standard method (ESM and quantitative analysis of multicomponents by single-marker (QAMS. Ethanol extracts ranged from 9.749 to 15.644% and the mean value was 13.473%. The volatile oil ranged from 0.45 to 0.90 mL/100 g and the mean value was 0.66 mL/100 g. This method was accurate and feasible and could provide a reference for further comprehensive and effective control of the quality standard of Curcuma Longa Radix and its processed products.

  8. Study on Quality Standard of Processed Curcuma Longa Radix

    Science.gov (United States)

    Zhao, Yongfeng; Quan, Liang; Zhou, Haiting; Cao, Dong; Li, Wenbing; Yang, Zhuo

    2017-01-01

    To control the quality of Curcuma Longa Radix by establishing quality standards, this paper increased the contents of extract and volatile oil determination. Meanwhile, the curcumin was selected as the internal marker, and the relative correlation factors (RCFs) of demethoxycurcumin and bisdemethoxycurcumin were established by high performance liquid chromatography (HPLC). The contents of multicomponents were calculated based on their RCFs. The rationality and feasibility of the methods were evaluated by comparison of the quantitative results between external standard method (ESM) and quantitative analysis of multicomponents by single-marker (QAMS). Ethanol extracts ranged from 9.749 to 15.644% and the mean value was 13.473%. The volatile oil ranged from 0.45 to 0.90 mL/100 g and the mean value was 0.66 mL/100 g. This method was accurate and feasible and could provide a reference for further comprehensive and effective control of the quality standard of Curcuma Longa Radix and its processed products. PMID:29375640

  9. Rethinking Space Design Standards Toward Quality Affordable Housing In Malaysia

    Directory of Open Access Journals (Sweden)

    Ishak Nor Haniza

    2016-01-01

    Full Text Available Provision of affordable housing is important to low- and middle-income population. A fit form of house will not only fulfil a basic human need for shelter, but it also contributes to physical and psychological well-being of the occupants. Excellent quality and affordable housing is an indication of a high quality of life. While writings exist on various aspects of the quality of affordable housing in Malaysia, discussion regarding space and design standards has scarcely been given any serious academic attention. Standards concerning residential development usually cover different aspects or stages of the development process. They can include planning standards, design standards, space standards and technical construction standards. The main concern of this paper is on space and design standards specifically. Space standard can be defined as a set of framework which dictates fixed internal space minimums. Meanwhile, design standard indicates design guidelines to ensure the functionality, comfortability and habitability of the house. This paper is concerned exclusively with indoor spaces of a house excluding external circulation spaces and service facilities (in case of strata housing. Its interest is in internal space as an aspect of housing quality. It can be concluded that one of the way forward will be to find the balance between providing adequate minimum spaces for resident satisfactions and having economic values for housing developers. This paper may be used as a valuable reference for authorities and policy makers to better address the best housing space design standards that would benefit not only the occupants, but also the local government and developers alike.

  10. 40 CFR 35.2111 - Revised water quality standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Revised water quality standards. 35... stream segments which have not, at least once since December 29, 1981, had their water quality standards...) The State has in good faith submitted such water quality standards and the Regional Administrator has...

  11. Organizational, technical, physical and clinical quality standards for radiotherapy

    Science.gov (United States)

    Bogusz-Czerniewicz, Marta; Kaźmierczak, Daniel

    2012-01-01

    Background Indisputably, radiotherapy has become an entirely interdisciplinary specialty. This situation requires efficient planning, verification, monitoring, quality control and constant improvement of all aspects of service delivery, referring both to patients’ (including diagnosis, prescription and method of treatment, its justification, realization and follow up) and organizational, technical and physics matters. Aim The aim of this work was to develop technical, physics and clinical quality standards for radiotherapy. This paper presents chosen standards for each of the aforementioned category. Materials and methods For the development of quality standards the comparison analysis of EU and Polish acts of law passed between 1980 and 2010 was conducted, the universal industrial ISO norm 9001:2008 referring to quality management system was reviewed. Recommendations of this norm were completed with detailed quality standards based on the author's 11 year work experience and the review of articles on quality assurance and quality control standards for radiotherapy published between 1984 and 2009 and the review of current recommendations and guidelines of American, International, European and National bodies (associations, societies, agencies such as AAPM, ESTRO, IAEA, and OECI) for quality assurance and quality management in radiotherapy. Results As a result 352 quality standards for radiotherapy were developed and categorized into the following three groups: (1) organizational standards, (2) physics and technical standards and (3) clinical standards. Conclusions Proposed quality standards for radiotherapy, can be used by any institution using ionizing radiation for medical procedures. Nevertheless standards are only of value if they are implemented, reviewed, audited and improved and if there is a clear mechanism in place to monitor and address failure to meet agreed standards. PMID:24377023

  12. Air Quality of Beijing and Impacts of the New Ambient Air Quality Standard

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2015-08-01

    Full Text Available Beijing has been publishing daily reports on its air quality since 2000, and while the air pollution index (API shows that the air quality has improved greatly since 2000, this is not the perception of Beijing’s residents. The new national ambient air quality standard (NAAQS-2012, which includes the monitoring of PM2.5, has posed stricter standards for evaluating air quality. With the new national standard, the air quality in Beijing is calculated using both NAAQS-2012 and the previous standard. The annual attainment rate has dropped from 75.5% to 50.7%. The spatial analysis of air quality shows that only a background station could attain the national standard, while urban and suburban stations exceed the national standard. Among the six pollutants included in the NAAQS-2012, PM2.5 is the major contributor to the air quality index (AQI comparing with the five other pollutants. The results indicate that under previous NAAQS without PM2.5 monitoring, the air quality has improved greatly in the past decade.  By considering PM2.5, the air quality attainment has dropped greatly. Furthermore, a great effort is needed for local government to bring down the PM2.5 concentration.

  13. Zerodur polishing process for high surface quality and high efficiency

    International Nuclear Information System (INIS)

    Tesar, A.; Fuchs, B.

    1992-08-01

    Zerodur is a glass-ceramic composite importance in applications where temperature instabilities influence optical and mechanical performance, such as in earthbound and spaceborne telescope mirror substrates. Polished Zerodur surfaces of high quality have been required for laser gyro mirrors. Polished surface quality of substrates affects performance of high reflection coatings. Thus, the interest in improving Zerodur polished surface quality has become more general. Beyond eliminating subsurface damage, high quality surfaces are produced by reducing the amount of hydrated material redeposited on the surface during polishing. With the proper control of polishing parameters, such surfaces exhibit roughnesses of < l Angstrom rms. Zerodur polishing was studied to recommend a high surface quality polishing process which could be easily adapted to standard planetary continuous polishing machines and spindles. This summary contains information on a polishing process developed at LLNL which reproducibly provides high quality polished Zerodur surfaces at very high polishing efficiencies

  14. State Air Quality Standards.

    Science.gov (United States)

    Pollution Engineering, 1978

    1978-01-01

    This article presents in tabular form the air quality standards for sulfur dioxide, carbon monoxide, nitrogen dioxide, photochemicals, non-methane hydrocarbons and particulates for each of the 50 states and the District of Columbia. (CS)

  15. standards used for quality control of nuclear fuels

    International Nuclear Information System (INIS)

    Guereli, L; Can, S.

    1997-01-01

    Nuclear fuels and fuel materials are subject to stringent restrictions as to their quality. The standards and regulations that apply vary according to reactor type and country and the standards are stated in the quality assurance documents. The concept of quality assurance has altered the conventional quality control tests and procedures, defining which control tests are to be applied and how. Although most of the tests and measurements allow the determination of tolerances to be decided according to the agreement between the buyer and the seller, exacting procedures apply to which instruments and equipment are used for these tests and measurements, how these instruments are standardized.Detailed explanations of test methods and their documentation is a requirement in all standards. The purpose of this work is to study which standards, tests and measurements apply to the nuclear fuel production. Only the standards that apply to various stages of the nuclear fuel production (powder preparation, pellet production, fuel element and fuel assembly fabrication) are reviewed. Process and documentation control, design and licensing requirements and the frequency of inspections are quality assurance subjects. Some ASTM standards are given as examples

  16. Air Pollution Monitoring | Air Quality Planning & Standards ...

    Science.gov (United States)

    2016-06-08

    The basic mission of the Office of Air Quality Planning and Standards is to preserve and improve the quality of our nation's air. To accomplish this, OAQPS must be able to evaluate the status of the atmosphere as compared to clean air standards and historical information.

  17. A comparative analysis of quality management standards for contract research organisations in clinical trials.

    Science.gov (United States)

    Murray, Elizabeth; McAdam, Rodney

    2007-01-01

    This article compares and contrasts the main quality standards in the highly regulated pharmaceutical industry with specific focus on Good Clinical Practice (GCP), the standard for designing, conducting, recording and reporting clinical trials involving human participants. Comparison is made to ISO quality standards, which can be applied to all industries and types of organisation. The study is then narrowed to that of contract research organisations (CROs) involved in the conduct of clinical trials. The paper concludes that the ISO 9000 series of quality standards can act as a company-wide framework for quality management within such organisations by helping to direct quality efforts on a long-term basis without any loss of compliance. This study is valuable because comparative analysis in this domain is uncommon.

  18. Quality assurance: Importance of systems and standard operating procedures.

    Science.gov (United States)

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  19. Quality assurance: Importance of systems and standard operating procedures

    Directory of Open Access Journals (Sweden)

    Kishu Manghani

    2011-01-01

    Full Text Available It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  20. Do semantic standards lack quality? A survey among 34 semantic standards

    NARCIS (Netherlands)

    Folmer, E.J.A.; Oude Luttighuis, P.H.W.M.; Hillegersberg, J. van

    2011-01-01

    The adoption of standards to improve interoperability in the automotive, aerospace, shipbuilding and other sectors could save billions. While interoperability standards have been created for a number of industries, problems persist, suggesting a lack of quality of the standards themselves. The issue

  1. Do semantic standards lack quality? A survey among 34 semantic standards.

    NARCIS (Netherlands)

    Folmer, Erwin Johan Albert; Oude Luttighuis, Paul; van Hillegersberg, Jos

    2011-01-01

    The adoption of standards to improve interoperability in the automotive, aerospace, shipbuilding and other sectors could save billions. While interoperability standards have been created for a number of industries, problems persist, suggesting a lack of quality of the standards themselves. The issue

  2. A Microfluidic Immunostaining System Enables Quality Assured and Standardized Immunohistochemical Biomarker Analysis

    Science.gov (United States)

    Kwon, Seyong; Cho, Chang Hyun; Kwon, Youngmee; Lee, Eun Sook; Park, Je-Kyun

    2017-04-01

    Immunohistochemistry (IHC) plays an important role in biomarker-driven cancer therapy. Although there has been a high demand for standardized and quality assured IHC, it has rarely been achieved due to the complexity of IHC testing and the subjective validation-based process flow of IHC quality control. We present here a microfluidic immunostaining system for the standardization of IHC by creating a microfluidic linearly graded antibody (Ab)-staining device and a reference cell microarray. Unlike conventional efforts, our system deals primarily with the screening of biomarker staining conditions for quantitative quality assurance testing in IHC. We characterized the microfluidic matching of Ab staining intensity using three HER2 Abs produced by different manufacturers. The quality of HER2 Ab was also validated using tissues of breast cancer patients, demonstrating that our system is an efficient and powerful tool for the standardization and quality assurance of IHC.

  3. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  4. Higher Education Quality Assessment Model: Towards Achieving Educational Quality Standard

    Science.gov (United States)

    Noaman, Amin Y.; Ragab, Abdul Hamid M.; Madbouly, Ayman I.; Khedra, Ahmed M.; Fayoumi, Ayman G.

    2017-01-01

    This paper presents a developed higher education quality assessment model (HEQAM) that can be applied for enhancement of university services. This is because there is no universal unified quality standard model that can be used to assess the quality criteria of higher education institutes. The analytical hierarchy process is used to identify the…

  5. Evaluating Education Quality in Terms of ISO9000 Standards

    Science.gov (United States)

    Fengchun, Cheng; Vogel, Linda R.; Zhaoyu, Zheng

    2014-01-01

    While nations measure the quality of educational systems by different standards, many nations, such as China, have adopted the ISO9000 quality standards to assess the quality of schools. This article explores the various elements of the the ISO9000 standards and how each element relates to the various groups that are consumers or stakeholders in…

  6. 40 CFR 131.22 - EPA promulgation of water quality standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false EPA promulgation of water quality... PROGRAMS WATER QUALITY STANDARDS Procedures for Review and Revision of Water Quality Standards § 131.22 EPA promulgation of water quality standards. (a) If the State does not adopt the changes specified by the Regional...

  7. 77 FR 30087 - Air Quality Designations for the 2008 Ozone National Ambient Air Quality Standards

    Science.gov (United States)

    2012-05-21

    ... and 81 Air Quality Designations for the 2008 Ozone National Ambient Air Quality Standards; Implementation of the 2008 National Ambient Air Quality Standards for Ozone: Nonattainment Area Classifications...-9668-2] RIN 2060-AP37 Air Quality Designations for the 2008 Ozone National Ambient Air Quality...

  8. Synthetic salt cake standards for analytical laboratory quality control

    International Nuclear Information System (INIS)

    Schilling, A.E.; Miller, A.G.

    1980-01-01

    The validation of analytical results in the characterization of Hanford Nuclear Defense Waste requires the preparation of synthetic waste for standard reference materials. Two independent synthetic salt cake standards have been prepared to monitor laboratory quality control for the chemical characterization of high-level salt cake and sludge waste in support of Rockwell Hanford Operations' High-Level Waste Management Program. Each synthetic salt cake standard contains 15 characterized chemical species and was subjected to an extensive verification/characterization program in two phases. Phase I consisted of an initial verification of each analyte in salt cake form in order to determine the current analytical capability for chemical analysis. Phase II consisted of a final characterization of those chemical species in solution form where conflicting verification data were observed. The 95 percent confidence interval on the mean for the following analytes within each standard is provided: sodium, nitrate, nitrite, phosphate, carbonate, sulfate, hydroxide, chromate, chloride, fluoride, aluminum, plutonium-239/240, strontium-90, cesium-137, and water

  9. Standardization and quality management in next-generation sequencing.

    Science.gov (United States)

    Endrullat, Christoph; Glökler, Jörn; Franke, Philipp; Frohme, Marcus

    2016-09-01

    DNA sequencing continues to evolve quickly even after > 30 years. Many new platforms suddenly appeared and former established systems have vanished in almost the same manner. Since establishment of next-generation sequencing devices, this progress gains momentum due to the continually growing demand for higher throughput, lower costs and better quality of data. In consequence of this rapid development, standardized procedures and data formats as well as comprehensive quality management considerations are still scarce. Here, we listed and summarized current standardization efforts and quality management initiatives from companies, organizations and societies in form of published studies and ongoing projects. These comprise on the one hand quality documentation issues like technical notes, accreditation checklists and guidelines for validation of sequencing workflows. On the other hand, general standard proposals and quality metrics are developed and applied to the sequencing workflow steps with the main focus on upstream processes. Finally, certain standard developments for downstream pipeline data handling, processing and storage are discussed in brief. These standardization approaches represent a first basis for continuing work in order to prospectively implement next-generation sequencing in important areas such as clinical diagnostics, where reliable results and fast processing is crucial. Additionally, these efforts will exert a decisive influence on traceability and reproducibility of sequence data.

  10. Quality control and quality standards for the production of bone allografts in China

    International Nuclear Information System (INIS)

    Sun Shiquan; Li Youchen

    1999-01-01

    There is a rapid progress of tissue banking especially Bone Banking in China, In order to strengthen the control on medical devices, Ministry of Public Health (MPH) issued the 'Regulation on Supervision of Critical Medical Devices, MPH Decree No. 54' in 1997. The SPTB was requested to submit new application for the approval of production and providing of tissue allografts. The needed documents are clinical reports, package insert, quality standards of product, Quality System Regulation (QSR) and audit report. Quality System Regulation document adopted the GMP standard for medical devices of FDA, US (21 CFR 620-1997). SPTB will amend the existed Quality Manual to suit the requirement of QSR. Referring to the AATB Standards, SPTB established 'Technical Standards' for Tissue Banking and was approved by the local government, which will be the supplement of the submitted QSR document. Considering the need of market control, MPH requested to submit a 'Quality Standard of Product' and the method of inspection. SPTB has completed such standards for final inspection of bone products, which includes the test for residual water, microbiology, bone species, colour and structure. In addition, the Tissue Bank has completed standards for in process inspection, which includes residual blood, radiation sterilization, initial bioburden, package leakage and biomechanics. In-process inspection is important for the control of non-conforming final products to assure the safety and efficacy of bone grafts. Methods of in process inspection and final inspection are described and discussed in this paper

  11. Knowledge, attitude, and practice of quality standards in small-sized public hospitals, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Fahad Khamis Alomari

    2015-01-01

    Full Text Available Objectives: The aim of this study was to assess current situations in small size hospitals regarding knowledge of staff, their attitude and practice of quality standards, in order to set a plan to improve the current situations and overcome barriers of quality practice. Materials and Methods: A descriptive cross-sectional research was conducted by a validated self-administered questionnaire using systematic random technique. Results: The study included about 37.7% Physicians followed by 28.3% nurses, and 18.8% administrators. Median percentage of participants′ knowledge and attitude scores regarding healthcare quality was 48% and 80% respectively. Meanwhile, the median percentage of participants′ perception toward hospital support and implementation of healthcare quality was 54% and 50% respectively. The main barriers for quality standards implementation and practicing were; staff resistance (84.8% followed by deficient knowledge (81.1%. Knowledge showed significant positive correlation with hospital application of quality standards (P = 0.001. Conclusion: The researcher concluded that improvement of knowledge and attitude toward implementation of quality standards as well as leadership commitment to quality and change management were a critical element for organisational shifting transformation to implementing quality of care. Focusing on small hospital and providing more support with all resources for implementation of quality standards through proper education and training for all staff categories are highly recommended.

  12. Ambient assisted living healthcare frameworks, platforms, standards, and quality attributes.

    Science.gov (United States)

    Memon, Mukhtiar; Wagner, Stefan Rahr; Pedersen, Christian Fischer; Beevi, Femina Hassan Aysha; Hansen, Finn Overgaard

    2014-03-04

    Ambient Assisted Living (AAL) is an emerging multi-disciplinary field aiming at exploiting information and communication technologies in personal healthcare and telehealth systems for countering the effects of growing elderly population. AAL systems are developed for personalized, adaptive, and anticipatory requirements, necessitating high quality-of-service to achieve interoperability, usability, security, and accuracy. The aim of this paper is to provide a comprehensive review of the AAL field with a focus on healthcare frameworks, platforms, standards, and quality attributes. To achieve this, we conducted a literature survey of state-of-the-art AAL frameworks, systems and platforms to identify the essential aspects of AAL systems and investigate the critical issues from the design, technology, quality-of-service, and user experience perspectives. In addition, we conducted an email-based survey for collecting usage data and current status of contemporary AAL systems. We found that most AAL systems are confined to a limited set of features ignoring many of the essential AAL system aspects. Standards and technologies are used in a limited and isolated manner, while quality attributes are often addressed insufficiently. In conclusion, we found that more inter-organizational collaboration, user-centered studies, increased standardization efforts, and a focus on open systems is needed to achieve more interoperable and synergetic AAL solutions.

  13. Ambient Assisted Living Healthcare Frameworks, Platforms, Standards, and Quality Attributes

    Directory of Open Access Journals (Sweden)

    Mukhtiar Memon

    2014-03-01

    Full Text Available Ambient Assisted Living (AAL is an emerging multi-disciplinary field aiming at exploiting information and communication technologies in personal healthcare and telehealth systems for countering the effects of growing elderly population. AAL systems are developed for personalized, adaptive, and anticipatory requirements, necessitating high quality-of-service to achieve interoperability, usability, security, and accuracy. The aim of this paper is to provide a comprehensive review of the AAL field with a focus on healthcare frameworks, platforms, standards, and quality attributes. To achieve this, we conducted a literature survey of state-of-the-art AAL frameworks, systems and platforms to identify the essential aspects of AAL systems and investigate the critical issues from the design, technology, quality-of-service, and user experience perspectives. In addition, we conducted an email-based survey for collecting usage data and current status of contemporary AAL systems. We found that most AAL systems are confined to a limited set of features ignoring many of the essential AAL system aspects. Standards and technologies are used in a limited and isolated manner, while quality attributes are often addressed insufficiently. In conclusion, we found that more inter-organizational collaboration, user-centered studies, increased standardization efforts, and a focus on open systems is needed to achieve more interoperable and synergetic AAL solutions.

  14. FACTORS DESCRIBING STUDENTS´ PERCEPTION ON EDUCATION QUALITY STANDARDS

    Directory of Open Access Journals (Sweden)

    Lucie Vnoučková

    2017-12-01

    Full Text Available Education quality assurance is the necessity for today’s competitive environment in university education. Quality assurance standards and strategies are being used in most of universities and higher education institutions. But the perception of quality standards is being usually seen from the perspective of a university management. This study aims to analyze and present perceptions of students towards a measurement of education quality standards and to identify significant groups of students according to their preferences in education quality. Students’ questionnaires and focus groups collected the data. Two dimensional and multi-dimensional statistical methods were used to evaluate the results. The outputs show five groups of students based on their perception of the education quality. Examination of students’ interest in specific areas, subjects and courses leads to identification of factors which affect their preferences in education. The paper found five significant groups of perceived quality by students. These are Quality receptionists, Business oriented, Expert innovators, Distance learners and Arrangement oriented. Limit of the study is a narrow focus on one private university. This study may encourage other papers to develop and test further the impact of education quality on students’ preferences for measurable improvements. The paper is an extension of the conference paper presented on ERIE conference 2017.

  15. The case for regime-based water quality standards

    Science.gov (United States)

    G.C. Poole; J.B. Dunham; D.M. Keenan; S.T. Sauter; D.A. McCullough; C. Mebane; J.C. Lockwood; D.A. Essig; M.P. Hicks; D.J. Sturdevant; E.J. Materna; S.A. Spalding; J. Risley; M. Deppman

    2004-01-01

    Conventional water quality standards have been successful in reducing the concentration of toxic substances in US waters. However, conventional standards are based on simple thresholds and are therefore poorly structured to address human-caused imbalances in dynamic, natural water quality parameters, such as nutrients, sediment, and temperature. A more applicable type...

  16. 40 CFR 131.20 - State review and revision of water quality standards.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) WATER PROGRAMS WATER QUALITY STANDARDS Procedures for Review and Revision of Water Quality Standards § 131.20 State review and revision of water quality standards. (a) State review. The State shall... reviewing applicable water quality standards and, as appropriate, modifying and adopting standards. Any...

  17. Study on the testing standards of quality assurance for CT image

    International Nuclear Information System (INIS)

    Liu Jingxin; Yang Haishan; Liu Gang; Wang Liyun

    2000-01-01

    Objective: To establish national testing standards of quality assurance for CT image. Methods: 104 sets of CT system were tested using quality assurance test phantoms and devices including American RMI 461A, RMI 463, MDH 1015 C with ION Chamber, Sweden UNF 9004 kvp meter. These CT were made from different manufacturers including out of date of CT and state-of-art spiral CT system. Thirteen kinds of standards on CT from different countries and 87 sets of technical specifications of CT were collected. The results of the test were compared using phantoms of RMI, Victoreen, Catphan on the same CT system (Siemens HQS). Results: Based on the test results of this study, with reference to the foreign standards and some of regulations in China, CT test items should include high contrast resolution, low contrast resolution, noise, uniformity, mean CT unit, dose slice thickness, localization light, positioning of patient support and gantry tilt. Standards including acceptance test, status test, and constancy test were made in specification. Among them, constancy test equals to IEC 122-2-6; items and results in acceptance test are stricter than in the status test; and low contrast resolution, uniformity, localization light accuracy and positioning of patient support in the acceptance test are even stricter than that in foreign standards. Conclusion: The testing standards of quality assurance for CT developed in this study shows practical and useful in China, which supplemented to the existing international standards

  18. Re-Establishment of Standard Radiation Qualities for Calibration of Dosemeter in Diagnostic Radiology - RQR Series

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Norhayati Abdullah; Mohd Firdaus Abd Rahman

    2016-01-01

    After repairing the high voltage (HV) generator for Philips MG165 X-Ray Machine, the reestablishment of the standard radiation qualities has been done at Medical Physics Calibration Laboratory to meet the IEC and IAEA standard. Standard radiation qualities are the important criteria for calibration of dosemeter in diagnostic radiology. Standard radiation qualities are defined as the added filtration needed to produce and the half value layer (HVL) of the beam for specifies x-ray tube kilo voltage (kV). For calibration of dosemeter in diagnostic radiology, standard radiation qualities RQR represent the beam incident on the patient in general radiography, fluoroscopy and dental application. The HVL were measured using PTW ion chamber of volume 1 cm"3 with PTW electrometer and aluminium filter with 99.9 % purity was used as additional filter for RQR and filter for HVL. The first establishment of standard radiation qualities was made in 2009 for the radiation qualities of RQR. The results of additional filter and 1st HVL from 2009 to 2016 will be discussed further in paper. The ratios of the measured HVL to the standard IEC HVL value for the RQR series also described in this paper. The details of the measurement and the results are described in this paper. (author)

  19. 40 CFR 131.21 - EPA review and approval of water quality standards.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) WATER PROGRAMS WATER QUALITY STANDARDS Procedures for Review and Revision of Water Quality Standards § 131.21 EPA review and approval of water quality standards. (a) After the State submits its... analysis. (b) The Regional Administrator's approval or disapproval of a State water quality standard shall...

  20. 76 FR 72097 - Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards

    Science.gov (United States)

    2011-11-22

    ... Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY: This rule establishes air quality designations for most areas in the United States for the 2008 lead (Pb) National Ambient Air Quality Standards...

  1. ISO 9001:2000--setting the standard for quality management.

    Science.gov (United States)

    Edelstein, M E

    2001-04-01

    How will you approach the next quality management initiative? This article offers an introduction to the ISO 9001:2000 quality management system standards that can be applied to the HIM industry and how these standards can improve your department's policies and procedures.

  2. [Discussion on research thinking of traditional Chinese medicine standardization system based on whole process quality control].

    Science.gov (United States)

    Dong, Ling; Sun, Yu; Pei, Wen-Xuan; Dai, Jun-Dong; Wang, Zi-Yu; Pan, Meng; Chen, Jiang-Peng; Wang, Yun

    2017-12-01

    The concept of "Quality by design" indicates that good design for the whole life cycle of pharmaceutical production enables the drug to meet the expected quality requirements. Aiming at the existing problems of the traditional Chinese medicine (TCM) industry, the TCM standardization system was put forward in this paper from the national strategic level, under the guidance by the idea of quality control in international manufacturing industry and with considerations of TCM industry's own characteristics and development status. The connotation of this strategy was to establish five interrelated systems: multi-indicators system based on tri-indicators system, quality standard and specification system of TCM herbal materials and decoction pieces, quality traceability system, data monitoring system based on whole-process quality control, and whole-process quality management system of TCM, and achieve the whole process systematic and scientific study in TCM industry through "top-level design-implement in steps-system integration" workflow. This article analyzed the correlation between the quality standards of all links, established standard operating procedures of each link and whole process, and constructed a high standard overall quality management system for TCM industry chains, in order to provide a demonstration for the establishment of TCM whole-process quality control system and provide systematic reference and basis for standardization strategy in TCM industry. Copyright© by the Chinese Pharmaceutical Association.

  3. The emerging High Efficiency Video Coding standard (HEVC)

    International Nuclear Information System (INIS)

    Raja, Gulistan; Khan, Awais

    2013-01-01

    High definition video (HDV) is becoming popular day by day. This paper describes the performance analysis of latest upcoming video standard known as High Efficiency Video Coding (HEVC). HEVC is designed to fulfil all the requirements for future high definition videos. In this paper, three configurations (intra only, low delay and random access) of HEVC are analyzed using various 480p, 720p and 1080p high definition test video sequences. Simulation results show the superior objective and subjective quality of HEVC

  4. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

    Science.gov (United States)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

  5. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics, Three Decades of High-quality, Technically-rigorous Normalization

    Science.gov (United States)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high quality, rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards provide accurate, reliable, repeatable and complete data. Within Committee C28 users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, nearly 50 standards since the Committees founding in 1986. This paper provides a retrospective review of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of advanced ceramics standards to demonstrate their practical applications.

  6. Quality standards in 480 pancreatic resections: a prospective observational study

    Directory of Open Access Journals (Sweden)

    Francisco Javier Herrera-Cabezón

    2015-03-01

    Full Text Available Pancreatic resection is a standard procedure for the treatment of periampullary tumors. Morbidity and mortality are high, and quality standards are scarce in our setting. International classifications of complications (Clavien-Dindo and those specific for pancreatectomies (ISGPS allow adequate case comparisons. The goals of our work are to describe the morbidity and mortality of 480 pancreatectomies using the international classifications ISGPS and Clavien-Dindo to help establish a quality standard in our setting and to compare the results of CPD with reconstruction by pancreaticogastrostomy (1,55 versus 177 pancreaticojejunostomy. We report 480 resections including 337 duodenopancreatectomies, 116 distal pancreatectomies, 11 total pancreatectomies, 10 central pancreatectomies, and 6 enucleations. Results for duodenopancreatectomy include: 62 % morbidity (Clavien ≥ III 25.9 %, 12.3 % reinterventions, and 3.3 % overall mortality. For reconstruction by pancreaticojejunostomy: 71.2 % morbidity (Clavien ≥ III 34.4 %, 17.5 % reinterventions, and 3.3 % mortality. For reconstruction by pancreaticogastrostomy: 51 % morbidity (Clavien ≥ III 15.4%, 6.4 % reinterventions, and 3.2 % mortality. Differences are significant except for mortality. We conclude that our series meets quality criteria as compared to other groups. Reconstruction with pancreaticogastrostomy significantly reduces complication number and severity, as well as pancreatic fistula and reintervention rates.

  7. Standards of care and quality indicators for multidisciplinary care models for psoriatic arthritis in Spain.

    Science.gov (United States)

    Gratacós, Jordi; Luelmo, Jesús; Rodríguez, Jesús; Notario, Jaume; Marco, Teresa Navío; de la Cueva, Pablo; Busquets, Manel Pujol; Font, Mercè García; Joven, Beatriz; Rivera, Raquel; Vega, Jose Luis Alvarez; Álvarez, Antonio Javier Chaves; Parera, Ricardo Sánchez; Carrascosa, Jose Carlos Ruiz; Martínez, Fernando José Rodríguez; Sánchez, José Pardo; Olmos, Carlos Feced; Pujol, Conrad; Galindez, Eva; Barrio, Silvia Pérez; Arana, Ana Urruticoechea; Hergueta, Mercedes; Coto, Pablo; Queiro, Rubén

    2018-06-01

    To define and give priority to standards of care and quality indicators of multidisciplinary care for patients with psoriatic arthritis (PsA). A systematic literature review on PsA standards of care and quality indicators was performed. An expert panel of rheumatologists and dermatologists who provide multidisciplinary care was established. In a consensus meeting group, the experts discussed and developed the standards of care and quality indicators and graded their priority, agreement and also the feasibility (only for quality indicators) following qualitative methodology and a Delphi process. Afterwards, these results were discussed with 2 focus groups, 1 with patients, another with health managers. A descriptive analysis is presented. We obtained 25 standards of care (9 of structure, 9 of process, 7 of results) and 24 quality indicators (2 of structure, 5 of process, 17 of results). Standards of care include relevant aspects in the multidisciplinary care of PsA patients like an appropriate physical infrastructure and technical equipment, the access to nursing care, labs and imaging techniques, other health professionals and treatments, or the development of care plans. Regarding quality indicators, the definition of multidisciplinary care model objectives and referral criteria, the establishment of responsibilities and coordination among professionals and the active evaluation of patients and data collection were given a high priority. Patients considered all of them as important. This set of standards of care and quality indicators for the multidisciplinary care of patients with PsA should help improve quality of care in these patients.

  8. The Quality Control of Reference Standards in Metrology Dosimetry

    International Nuclear Information System (INIS)

    Lazarevic, Dj.; Ciraj Bjelac, O.; Kovacevic, M.; Vukcevic, M.

    2008-01-01

    This works presents the quality control tests applied to two types of ionization chambers with suitable electrometers. Measuring assemblies were tested in order to assess their performance and adequacy for use as reference standards in ionising radiation metrology laboratory for calibrations in the field of radiotherapy and radiation protection. Two types of ionizing chambers (Farmer type, 0.6 cm 3 and spherical ionizing chamber, 1 l) with suitable electrometers were tested. Following test were performed: repeatability, long term stability, polarity and leakage current measurement. All tested measuring assemblies demonstrated proper performance, correctness and high reliance of measurements, since all implemented quality control test results were within acceptable limits. (author)

  9. Environmental Quality Standards in the EC-Water Framework Directive

    DEFF Research Database (Denmark)

    Jirka, Gerhard H.; Burrows, Richard; Larsen, Torben

    2004-01-01

    The "combined approach" in the new EC-Water Framework Directive(WFD) consisting of environmental quality standards in addition to emission limit values promises improvements in the quality characteristics of surface water. However, the specification of where in the water body the environmental...... quality standards apply is missing in the WFD. The omission will limit its administrative implementation. A clear mixing zone regulation is needed so that the quality objectives of the WFD are not jeopardized. This need is demonstrated using the examples of point source discharges into rivers and coastal...

  10. New international and national standards concerning quality systems

    International Nuclear Information System (INIS)

    Petrick, K.; Reihlen, H.

    1987-01-01

    The history and contents of the latest standards DIN ISO 9000 through DIN ISO 9004 concerning quality systems are outlined. Information is given referring to the establishment of an in-house quality system, and to quality assurance requirements put down in a three-step quality assurance system for contractual purposes. The services available for certification of quality systems by the 'DQS' and legal aspects are mentioned. (HP)

  11. 40 CFR 121.25 - Adoption of new water quality standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Adoption of new water quality... Administrator § 121.25 Adoption of new water quality standards. (a) In any case where: (1) A license or permit was issued without certification due to the absence of applicable water quality standards; and (2...

  12. British Thoracic Society Quality Standards for acute non-invasive ventilation in adults

    Science.gov (United States)

    Davies, Michael; Allen, Martin; Bentley, Andrew; Bourke, Stephen C; Creagh-Brown, Ben; D’Oliveiro, Rachel; Glossop, Alastair; Gray, Alasdair; Jacobs, Phillip; Mahadeva, Ravi; Moses, Rachael; Setchfield, Ian

    2018-01-01

    Introduction The purpose of the quality standards document is to provide healthcare professionals, commissioners, service providers and patients with a guide to standards of care that should be met for the provision of acute non-invasive ventilation in adults together with measurable markers of good practice. Methods Development of British Thoracic Society (BTS) Quality Standards follows the BTS process of quality standard production based on the National Institute for Health and Care Excellence process manual for the development of quality standards. Results 6 quality statements have been developed, each describing a standard of care for the provision of acute non-invasive ventilation in the UK, together with measurable markers of good practice. Conclusion BTS Quality Standards for acute non-invasive ventilation in adults form a key part of the range of supporting materials that the Society produces to assist in the dissemination and implementation of guideline’s recommendations. PMID:29636979

  13. Quality assurance in cancer management. Impact of quality standards on treatment accuracy: The experience of the EORTC

    International Nuclear Information System (INIS)

    Bernier, J.

    1997-01-01

    There is thus a need to ensure that the same quality of treatment is offered to all cancer patients in Europe. A research of this kind must be aimed at identifying which steps in the complex treatment processes are more error prove, which of those can most effectively be corrected, and which procedures could be taken over by countries, or individual centers to monitor themselves the quality of their treatment procedures. To achieve this goals, the EORTC Radiotherapy Co-operative Group has put a major effort in the development of two Quality Assurance programs: the Physics Audit program (PAQ) and in the Assurance of Protocol Compliance Program (APCP). In the PAO, a first survey conducted in 1986, on the radiotherapy infrastructure in European Centers participating in clinical trials showed that 20% of the centers encountered difficulties to comply with the EORTC requirements due to imbalance in staff or equipment. Besides radiotherapy infrastructure, the beam output was checked in 50 centers: a major problem was detected in 30% of the checked electron beams. Dosimetric recommendations were sent out to all radio-oncology departments active in the EORTC and a mailed measurement procedure was developed for the verification of the beam output in photon beams. The EORTC Radiotherapy Group has demonstrated that multicenter QA programs permit, through the pooling of a large number of data, auditing by specialists of implemented Quality Standards both in radiation physics and in clinical oncology, contributing to the basis for the development of harmonized quality procedures and standards in the therapeutic management of cancer. This type of QA program should also foster the interaction between several medical disciplines and promote the application of Quality Standards in community level hospitals. Current efforts are also put forth to develop common research instruments, such as the processing of database and MRI or CT-scan images through teleconferencing and the set up

  14. Publication and Distribution of Chinese Standard and Quality Books

    Institute of Scientific and Technical Information of China (English)

    Bai Demei

    2010-01-01

    @@ 1.A Brief Introduction to SPC Standards Press of China (SPC),founded in October,1963,is the largest publisher of standard and quality products in China.It publishes national standards,trade standards,and audio,video,electronic,and network products.

  15. An Approach to Establishing International Quality Standards for Medical Travel

    Directory of Open Access Journals (Sweden)

    Ondřej eKácha

    2016-03-01

    Full Text Available Traveling abroad to receive a non-elective treatment is expanding each year. Such rising popularity of medical travel and the absence of clear minimum quality requirements in this area urgently calls for setting international standards to ensure good practice and patient safety. The aim of this study is to identify the key domains in medical travel where such quality standards should be established. Drawing from the evidence-based OECD framework and an extensive literature review, this study proposes three critical areas for international quality standards in medical travel: minimum standards of health care facilities and third-party agencies, financial responsibility and patient-centeredness. Several cultural challenges are subsequently introduced that may pose a barrier to the development of the guidelines and should be additionally taken into consideration. Establishing international quality standards in medical travel enhances the benefits to patients and providers, which is urgently needed given the rapid growth in this industry.

  16. Establishment of quality, reliability and design standards for low, medium, and high power microwave hybrid microcircuits

    Science.gov (United States)

    Robinson, E. A.

    1973-01-01

    Quality, reliability, and design standards for microwave hybrid microcircuits were established. The MSFC Standard 85M03926 for hybrid microcircuits was reviewed and modifications were generated for use with microwave hybrid microcircuits. The results for reliability tests of microwave thin film capacitors, transistors, and microwave circuits are presented. Twenty-two microwave receivers were tested for 13,500 unit hours. The result of 111,121 module burn-in and operating hours for an integrated solid state transceiver module is reported.

  17. Quality management manual for production of high quality cassava flour

    DEFF Research Database (Denmark)

    Dziedzoave, Nanam Tay; Abass, Adebayo Busura; Amoa-Awua, Wisdom K.

    The high quality cassava flour (HQCF) industry has just started to evolve in Africa and elsewhere. The sustainability of the growing industry, the profitability of small- and medium-scale enterprises (SMEs) that are active in the industry and good-health of consumers can best be guaranteed through...... the adoption of proper quality and food safety procedures. Cassava processing enterprises involved in the productionof HQCF must therefore be commited to the quality and food safety of the HQCF. They must have the right technology, appropriate processing machhinery, standard testing instruments...... and the necessary technical expertise. This quality manual was therefore developed to guide small- to medium-scale cassava in the design and implematation of Hazard Analysis Critical Control Point (HACCP) system and Good manufacturing Practices (GMP) plans for HQCF production. It describes the HQCF production...

  18. Quality and standards in electronics

    CERN Document Server

    Tricker, Ray

    1997-01-01

    A manufacturer or supplier of electronic equipment or components needs to know the precise requirements for component certification and quality conformance to meet the demands of the customer. This book ensures that the professional is aware of all the UK, European and International necessities, knows the current status of these regulations and standards, and where to obtain them.

  19. UK key performance indicators and quality assurance standards for colonoscopy.

    Science.gov (United States)

    Rees, Colin J; Thomas Gibson, Siwan; Rutter, Matt D; Baragwanath, Phil; Pullan, Rupert; Feeney, Mark; Haslam, Neil

    2016-12-01

    Colonoscopy should be delivered by endoscopists performing high quality procedures. The British Society of Gastroenterology, the UK Joint Advisory Group on GI Endoscopy, and the Association of Coloproctology of Great Britain and Ireland have developed quality assurance measures and key performance indicators for the delivery of colonoscopy within the UK. This document sets minimal standards for delivery of procedures along with aspirational targets that all endoscopists should aim for. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. Does Deregulation of Quality Standards in Telecomunications Improve Social Welfare? A Methodological Note Does Deregulation of Quality Standards in Telecomunications Improve Social Welfare? A Methodological Note

    OpenAIRE

    Felipe Morandé

    1990-01-01

    Does Deregulation of Quality Standards in Telecomunications Improve Social Welfare? A Methodological Note One of the main reasons behind the bit difference observed in the per capita number of telephones between develope and developing countries is the high capital cost -a scarce resource in LDC's- of expanding telecommunications infrastructure. A reasonable question to raise in this context is the extent to which that high capital cost of investment could be diminished if international quali...

  1. Review and comparison of quality standards, guidelines and regulations for laboratories

    Directory of Open Access Journals (Sweden)

    Tjeerd A.M. Datema

    2011-12-01

    Full Text Available Background: The variety and number of laboratory quality standards, guidelines and regulations (hereafter: quality documents makes it difficult to choose the most suitable one for establishing and maintaining a laboratory quality management system. Objectives: There is a need to compare the characteristics, suitability and applicability of quality documents in view of the increasing efforts to introduce quality management in laboratories, especially in clinical diagnostic laboratories in low income and middle income countries. This may provide valuable insights for policy makers developing national laboratory policies, and for laboratory managers and quality officers in choosing the most appropriate quality document for upgrading their laboratories. Method: We reviewed the history of quality document development and then selected a subset based on their current use. We analysed these documents following a framework for comparison of quality documents that was adapted from the Clinical Laboratory Standards Institute guideline GP26 Quality management system model for clinical laboratory services. Results: Differences were identified between national and international, and non-clinical and clinical quality documents. The most salient findings were the absence of provisions on occurrence management and customer service in almost all non-clinical quality documents, a low number of safety requirements aimed at protecting laboratory personnel in international quality documents and no requirements regarding ethical behaviour in almost all quality documents. Conclusion: Each laboratory needs to investigate whether national regulatory standards are present. These are preferred as they most closely suit the needs of laboratories in the country. A laboratory should always use both a standard and a guideline: a standard sums up the requirements to a quality management system, a guideline describes how quality management can be integrated in the laboratory

  2. 78 FR 66655 - Consumer Information; Uniform Tire Quality Grading Standards

    Science.gov (United States)

    2013-11-06

    ... information indicating the relative performance of passenger car tires in the areas of treadwear, traction... [Docket No. NHTSA-2013-0120] RIN 2127-AL49 Consumer Information; Uniform Tire Quality Grading Standards...). ACTION: Interim final rule; request for comments. SUMMARY: The Uniform Tire Quality Grading Standards...

  3. Tropical Fruit Pulps: Processing, Product Standardization and Main Control Parameters for Quality Assurance

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo de Farias Silva

    2017-05-01

    Full Text Available ABSTRACT Fruit pulp is the most basic food product obtained from fresh fruit processing. Fruit pulps can be cold stored for long periods of time, but they also can be used to fabricate juices, ice creams, sweets, jellies and yogurts. The exploitation of tropical fruits has leveraged the entire Brazilian fruit pulp sector due mainly to the high acceptance of their organoleptic properties and remarkable nutritional facts. However, several works published in the last decades have pointed out unfavorable conditions regarding the consumption of tropical fruit pulps. This negative scenario has been associated with unsatisfactory physico-chemical and microbiological parameters of fruits pulps as outcomes of little knowledge and improper management within the fruit pulp industry. There are protocols for delineating specific identity and quality standards (IQSs and standardized good manufacturing practices (GMP for fruit pulps, which also embrace standard operating procedures (SOPs and hazard analysis and critical control points (HACCP, although this latter is not considered mandatory by the Brazilian legislation. Unfortunately, the lack of skilled labor, along with failures in complying established protocols have impaired quality of fruit pulps. It has been necessary to collect all information available with the aim to identify the most important hazards within fruit pulp processing lines. Standardizing methods and practices within the Brazilian fruit pulp industry would assurance high quality status to tropical fruit pulps and the commercial growth of this vegetal product towards international markets.

  4. Implementation of quality standards in an individual monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hyvoenen, H.; Vartiainen, E

    2001-07-01

    In this paper the implementation of a quality system to the procedures of an individual monitoring service (IMS) is described from the practical perspective. The IMS of the Radiation and Nuclear Safety Authority (STUK) is used as an example. The IMS of STUK monitors about 8500 persons mainly working in hospitals, industry and research centres. The current thermoluminescence dosemeter (TLD) system was introduced in 1992 and the whole service changed to TLDs in 1995. The quality system compatible with the quality standards was introduced in 1999. An application for accreditation to full EN45001 and ISO/IEC Guide 25 was made in December 1999, accreditation was achieved in August 2000 by the Finnish Accreditation Service (FINAS). The considerations needed for the quality system to fulfil the requirements of the quality standards are reported. (author)

  5. Implementation of quality standards in an individual monitoring service

    International Nuclear Information System (INIS)

    Hyvoenen, H.; Vartiainen, E.

    2001-01-01

    In this paper the implementation of a quality system to the procedures of an individual monitoring service (IMS) is described from the practical perspective. The IMS of the Radiation and Nuclear Safety Authority (STUK) is used as an example. The IMS of STUK monitors about 8500 persons mainly working in hospitals, industry and research centres. The current thermoluminescence dosemeter (TLD) system was introduced in 1992 and the whole service changed to TLDs in 1995. The quality system compatible with the quality standards was introduced in 1999. An application for accreditation to full EN45001 and ISO/IEC Guide 25 was made in December 1999, accreditation was achieved in August 2000 by the Finnish Accreditation Service (FINAS). The considerations needed for the quality system to fulfil the requirements of the quality standards are reported. (author)

  6. Quality assurance requirements in various codes and standards

    International Nuclear Information System (INIS)

    Shaaban, H.I.; EL-Sayed, A.; Aly, A.E.

    1987-01-01

    The quality assurance requirements in various countries and according to various international codes and standards are presented, compared and critically discussed. Cases of developing countries are also discussed, and the use of IAEA code of practice and other codes for quality assurance in these countries is reviewed. Recommendations are made regarding the quality assurance system to be applied for Egypt's nuclear power plants

  7. 25 CFR 273.38 - Equal quality and standard of education.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Equal quality and standard of education. 273.38 Section... EDUCATION ASSISTANCE ACT PROGRAM EDUCATION CONTRACTS UNDER JOHNSON-O'MALLEY ACT Funding Provisions § 273.38 Equal quality and standard of education. Contracts with State education agencies or school districts...

  8. 40 CFR 125.61 - Existence of and compliance with applicable water quality standards.

    Science.gov (United States)

    2010-07-01

    ... applicable water quality standards. 125.61 Section 125.61 Protection of Environment ENVIRONMENTAL PROTECTION... Water Act § 125.61 Existence of and compliance with applicable water quality standards. (a) There must exist a water quality standard or standards applicable to the pollutant(s) for which a section 301(h...

  9. Progress in France of the standardization of multi-level quality assurance

    International Nuclear Information System (INIS)

    Debout, E.

    1982-01-01

    Quality assurance has evolved in a steady but somewhat haphazard manner in various industries, each of which has drawn up its own standards. Examples of this are the armaments industry under the auspices of NATO, nuclear energy (IAEA guides), the French aerospace industries and the Industrial Monitoring Service for Armaments in France. For the sake of both the supplier companies and the customers, these differing and sometimes incompatible requirements should be brought into line. At the instigation of the French Association for Industrial Quality Control (AFCIQ), the French Association for Standardization (AFNOR) is therefore in the process of publishing a series of documents on quality management and assurance. For its part, the International Organization for Standardization (ISO) has set up a committee (TC 176) to standardize quality assurance. The different documents provide for various levels of quality assurance, the compatibility of which will have to be closely monitored. (author)

  10. Reporting systems in gastrointestinal endoscopy: Requirements and standards facilitating quality improvement: European Society of Gastrointestinal Endoscopy position statement

    NARCIS (Netherlands)

    Bretthauer, Michael; Aabakken, Lars; Dekker, Evelien; Kaminski, Michal F.; Rösch, Thomas; Hultcrantz, Rolf; Suchanek, Stepan; Jover, Rodrigo; Kuipers, Ernst J.; Bisschops, Raf; Spada, Cristiano; Valori, Roland; Domagk, Dirk; Rees, Colin; Rutter, Matthew D.

    2016-01-01

    To develop standards for high quality of gastrointestinal endoscopy, the European Society of Gastrointestinal Endoscopy (ESGE) has established the ESGE Quality Improvement Committee. A prerequisite for quality assurance and improvement for all gastrointestinal endoscopy procedures is

  11. Stainless steel fabrication for high quality requirements in the nuclear industry

    International Nuclear Information System (INIS)

    Wareing, A.J.

    1990-01-01

    In this paper the author explains the welding procedures and practices adopted within the nuclear industry to achieve the high quality and standards of welds required. The changeover to mechanised welding, orbital TIG welding and synergic MIG welding, has resulted in consistent achievement of high quality standards as well as optimising the productivity. However, the use of mechanised welding machines does require the welder operating them to be fully trained and qualified. The formally organised training courses are described and the cost savings and production rates achieved by utilising the mechanised method are discussed. (author)

  12. 26 CFR 1.23-4 - Performance and quality standards. [Reserved

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 1 2010-04-01 2010-04-01 true Performance and quality standards. [Reserved] 1.23-4 Section 1.23-4 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY INCOME TAX INCOME TAXES Changes in Rates During A Taxable Year § 1.23-4 Performance and quality standards. [Reserved...

  13. Accounting quality and the adoption of IASB standards: portuguese evidence

    Directory of Open Access Journals (Sweden)

    Ana Isabel Morais

    2008-12-01

    Full Text Available Through rule 1606/2002 by the European Commission, Portuguese listed firms were required to adopt IASB standards in the preparation and presentation of consolidated accounts for the periods beginning on or after 2005. IASB standards are developed in environments where accounting practices are especially directed at the private sector, reporting rules are largely unaffected by taxation requirements and capital is traditionally raised in public markets. However, in Portugal, financial reporting is closely related to tax reporting and banks play a key role in providing finance and inside access to information. We investigate whether adopting IASB standards is associated with higher earnings quality and higher value relevance. We compare the earnings quality and value relevance of accounting data of 34 Portuguese listed firms before (1995-2004 and after (2004-2005 the adoption of IASB standards. We find that firms, during the period when they adopt IASB standards, report less smooth earnings than those firms in periods when they adopted national accounting standards, which seems to suggest an improvement in earnings quality. However, we also find that the value relevance of accounting information decreases with the adoption of IASB standards.

  14. The spectra of the standard x-ray qualities used in STUK's Radiation Metrology Laboratory

    International Nuclear Information System (INIS)

    Tapiovaara, T.; Tapiovaara, M.; Siiskonen, T.; Hakanen, A.

    2008-02-01

    This report presents the fluence spectra of the standard x-radiation qualities used in the Radiation Dosimetry Laboratory of Radiation and Nuclear Safety Authority (STUK). The spectra were measured in August 2007. The radiation qualities characterised in the report are the ISO Narrow spectrum series (ISO N10-N200, ISO 4037-1:1996) and both of the RQR-spectrum series specified by the IEC (IEC 1267:1994 and IEC 61267:2005). The measurements were made using a high purity Ge-detector and the measured pulse height spectra were corrected to fluence spectra. Spectral characteristics were computed from the spectral data and compared to the requirements in the standards and to the values given in the quality manual of the laboratory. (orig.)

  15. An IEC standard on quality assurance for diagnostic X-ray systems

    International Nuclear Information System (INIS)

    Boer, J.A. den

    1985-01-01

    A presentation is given of some characteristics of the International Electrotechnical Commission (IEC). This is followed by a short discussion of general aspects of quality assurance in the diagnostic department. From this discussion it becomes apparent to which aspects of quality assurance IEC can contribute. Within that framework a working group of Sub-Committee 62 is at present active in developing a standard on quality assurance for diagnostic X-ray systems. The standard will contain a set of constancy tests that is claimed to allow a balanced quality assurance programme. The democratic procedure of IEC should guarantee that the proposed standard gains wide acceptance. (author)

  16. Health care in small prisons: incorporating high-quality standards.

    Science.gov (United States)

    Rieder, Jean-Pierre; Casillas, Alejandra; Mary, Gérard; Secretan, Anne-Dominique; Gaspoz, Jean-Michel; Wolff, Hans

    2013-01-01

    In the past, health management in Geneva's six post-trial prisons had been variable and inconsistent. In 2008, the unit of penitentiary medicine of the Geneva University Hospitals was mandated to re-organize and provide health care at all six prison facilities. The specific aim of this paper is to outline the example as a practical solution to some of the common challenges in unifying the structure and process of health services across multiple small facilities, while meeting European prison health and local quality standards. Geneva's post-trial prisons are small and close to one another in geographical proximity - ideal conditions for the construction of a health mobile team (HMT). This multidisciplinary mobile team operated like a community ambulatory care model; it was progressively launched in all prison facilities in Geneva. The authors incorporated an implementation strategy where health providers partnered with prison and community stakeholders in the health delivery model's development and adaption process. The model's strategic initiatives are described along the following areas, in light of other international prison health activity and prior care models: access to a health care professional, equivalence of care, patient consent, confidentiality, humanitarian interventions, and professional competence and independence. From the perspective of the HMT members, the authors provide the "lessons learned" through this experience, especially to providers who are working on prison health services reform and coordination improvement. The paper particularly stresses the importance of partnering with community health stakeholders and prison staff, a key component to the approach.

  17. High dose gamma-ray standard

    International Nuclear Information System (INIS)

    Macrin, R.; Moraru, R.

    1999-01-01

    The high gamma-ray doses produced in a gamma irradiator are used, mainly, for radiation processing, i.e. sterilization of medical products, processing of food, modifications of polymers, irradiation of electronic devices, a.s.o. The used absorbed doses depend on the application and cover the range 10 Gy to 100 MGy. The regulations in our country require that the response of the dosimetry systems, used for the irradiation of food and medical products, be calibrated and traceable to the national standards. In order to be sure that the products receive the desired absorbed dose, appropriate dosimetric measurements must be performed, including the calibration of the dosemeters and their traceability to the national standards. The high dose gamma-ray measurements are predominantly based on the use of reference radiochemical dosemeters. Among them the ferrous sulfate can be used as reference dosemeter for low doses (up to 400 Gy) but due to its characteristics it deserves to be considered a standard dosemeter and to be used for transferring the conventional absorbed dose to other chemical dosemeters used for absorbed doses up to 100 MGy. The study of the ferrous sulfate dosemeter consisted in preparing many batches of solution by different operators in quality assurance conditions and in determining for all batches the linearity, the relative intrinsic error, the repeatability and the reproducibility. The principal results are the following: the linear regression coefficient: 0.999, the relative intrinsic error: max.6 %, the repeatability (for P* = 95 %): max.3 %, the reproducibility (P* = 95%): max.5 %. (authors)

  18. The International Standards for Solar Thermal Collectors and Components as a Medium of Quality Assurance

    International Nuclear Information System (INIS)

    Alkishriwi, Nouri; Schorn, Christian A.; Theis, Danjana

    2014-01-01

    regarding a product are fulfilled. In a certification process based on specified certification rules an authorized certification body is confirming that a solar thermal product has passed performance tests, reliability tests and further requirements according to the standards. In Europe a certification body holds an accreditation according to EN45011. At international level the standard ISO/IEC17065 is in force. Test results as a basis for product certification are determined by solar thermal test laboratories. The implementation and the business operation of such a solar thermal test laboratory is an important element within the national/regional solar thermal market. To ensure the quality of the products and to attend the role of an observer on the market, the test facility has to fulfill a number of requirements. Besides the necessary technical equipment and the implementation of tests in accordance with the various national and international standards, the laboratory shall realize a quality management system to guarantee the quality of tests and services. Based on the technical equipment, the testing scope and an implemented Quality Management System (QMS), the test laboratory can achieve an accreditation according to ISO/IEC17025 as basis for independent third party testing. Independent testing and evaluation of solar thermal collectors and components like hot water stores and controllers offers an important medium for quality assurance. To guarantee a high degree of product quality and consumer protection a quality system for the solar thermal market is necessary. Core of the quality assurance of a functioning solar thermal market are the national standards body, which is developing standards and regulations as a working basis ill technical committees, the national metrology institute that guarantees the traceability of measurements on fundamental and natural constants, and finally the national accreditation body which ensures the conformity of the various actors to a

  19. 78 FR 20252 - Water Quality Standards; Withdrawal of Certain Federal Water Quality Criteria Applicable to...

    Science.gov (United States)

    2013-04-04

    ... Water Quality Standards; Withdrawal of Certain Federal Water Quality Criteria Applicable to California... aquatic life water quality criteria applicable to waters of New Jersey, Puerto Rico, and California's San Francisco Bay. In 1992, EPA promulgated the National Toxics Rule or NTR to establish numeric water quality...

  20. Coordinating standards and applications for optical water quality sensor networks

    Science.gov (United States)

    Bergamaschi, B.; Pellerin, B.

    2011-01-01

    Joint USGS-CUAHSI Workshop: In Situ Optical Water Quality Sensor Networks; Shepherdstown, West Virginia, 8-10 June 2011; Advanced in situ optical water quality sensors and new techniques for data analysis hold enormous promise for advancing scientific understanding of aquatic systems through measurements of important biogeochemical parameters at the time scales over which they vary. High-frequency and real-time water quality data also provide the opportunity for early warning of water quality deterioration, trend detection, and science-based decision support. However, developing networks of optical sensors in freshwater systems that report reliable and comparable data across and between sites remains a challenge to the research and monitoring community. To address this, the U.S. Geological Survey (USGS) and the Consortium of Universities for the Advancement of Hydrologic Science, Inc. (CUAHSI), convened a 3-day workshop to explore ways to coordinate development of standards and applications for optical sensors, as well as handling, storage, and analysis of the continuous data they produce.

  1. Improving high quality, equitable maternal health services in Malawi ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Improving high quality, equitable maternal health services in Malawi (IMCHA) ... In response, the Ministry of Health implemented a Standards-Based Management and Recognition for Reproductive Health initiative to improve ... Total funding.

  2. Stable aesthetic standards delusion: changing 'artistic quality' by elaboration.

    Science.gov (United States)

    Carbon, Claus-Christian; Hesslinger, Vera M

    2014-01-01

    The present study challenges the notion that judgments of artistic quality are based on stable aesthetic standards. We propose that such standards are a delusion and that judgments of artistic quality are the combined result of exposure, elaboration, and discourse. We ran two experiments using elaboration tasks based on the repeated evaluation technique in which different versions of the Mona Lisa had to be elaborated deeply. During the initial task either the version known from the Louvre or an alternative version owned by the Prado was elaborated; during the second task both versions were elaborated in a comparative fashion. After both tasks multiple blends of the two versions had to be evaluated concerning several aesthetic key variables. Judgments of artistic quality of the blends were significantly different depending on the initially elaborated version of the Mona Lisa, indicating experience-based aesthetic processing, which contradicts the notion of stable aesthetic standards.

  3. Improving the safety and quality of nursing care through standardized operating procedures in Bosnia and Herzegovina.

    Science.gov (United States)

    Ausserhofer, Dietmar; Rakic, Severin; Novo, Ahmed; Dropic, Emira; Fisekovic, Eldin; Sredic, Ana; Van Malderen, Greet

    2016-06-01

    We explored how selected 'positive deviant' healthcare facilities in Bosnia and Herzegovina approach the continuous development, adaptation, implementation, monitoring and evaluation of nursing-related standard operating procedures. Standardized nursing care is internationally recognized as a critical element of safe, high-quality health care; yet very little research has examined one of its key instruments: nursing-related standard operating procedures. Despite variability in Bosnia and Herzegovina's healthcare and nursing care quality, we assumed that some healthcare facilities would have developed effective strategies to elevate nursing quality and safety through the use of standard operating procedures. Guided by the 'positive deviance' approach, we used a multiple-case study design to examine a criterion sample of four facilities (two primary healthcare centres and two hospitals), collecting data via focus groups and individual interviews. In each studied facility, certification/accreditation processes were crucial to the initiation of continuous development, adaptation, implementation, monitoring and evaluation of nursing-related SOPs. In one hospital and one primary healthcare centre, nurses working in advanced roles (i.e. quality coordinators) were responsible for developing and implementing nursing-related standard operating procedures. Across the four studied institutions, we identified a consistent approach to standard operating procedures-related processes. The certification/accreditation process is enabling necessary changes in institutions' organizational cultures, empowering nurses to take on advanced roles in improving the safety and quality of nursing care. Standardizing nursing procedures is key to improve the safety and quality of nursing care. Nursing and Health Policy are needed in Bosnia and Herzegovina to establish a functioning institutional framework, including regulatory bodies, educational systems for developing nurses' capacities or the

  4. Do Energy Efficiency Standards Improve Quality? Evidence from a Revealed Preference Approach

    Energy Technology Data Exchange (ETDEWEB)

    Houde, Sebastien [Univ. of Maryland, College Park, MD (United States); Spurlock, C. Anna [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-06-01

    Minimum energy efficiency standards have occupied a central role in U.S. energy policy for more than three decades, but little is known about their welfare effects. In this paper, we employ a revealed preference approach to quantify the impact of past revisions in energy efficiency standards on product quality. The micro-foundation of our approach is a discrete choice model that allows us to compute a price-adjusted index of vertical quality. Focusing on the appliance market, we show that several standard revisions during the period 2001-2011 have led to an increase in quality. We also show that these standards have had a modest effect on prices, and in some cases they even led to decreases in prices. For revision events where overall quality increases and prices decrease, the consumer welfare effect of tightening the standards is unambiguously positive. Finally, we show that after controlling for the effect of improvement in energy efficiency, standards have induced an expansion of quality in the non-energy dimension. We discuss how imperfect competition can rationalize these results.

  5. DOE standard: Quality assurance inspection and testing of HEPA filters

    International Nuclear Information System (INIS)

    1999-02-01

    This standard establishes essential elements for the quality assurance inspection and testing of HEPA filters by US Department of Energy (DOE)-accepted Filter Test Facilities (FTF). The standard specifies HEPA filter quality assurance inspection and testing practices established in DOE-STD-3022-98, DOE HEPA Filter Test Program, and provides a basis for the preparation of written operating procedures for primary FTF functions

  6. Quality standards and requirements for solid recovered fuels: a review.

    Science.gov (United States)

    Flamme, Sabine; Geiping, Julia

    2012-04-01

    The utilization of solid recovered fuels (SRF) for energy recovery has been increasing steadily in recent years, and this development is set to continue. In order to use SRF efficiently, it is necessary to define quality standards and introduce targeted quality assurance measures. SRF can be used both in mono-incineration and in co-incineration systems, for instance in power generation and cement plants; but as quality requirements differ, it is necessary to unambiguously define the term 'solid recovered fuel'. The purpose of this article is to provide an overview of the origin, development and the current status of quality assurance for SRF. The basic principles of quality assurance for SRF are explained with reference to the development of the German RAL Quality Assurance System and in addition specifications that have emerged from European standardization work of CEN/TC 343 are analysed.

  7. Search for adequate quality standards for neutron radiography of nuclear fuel

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1983-01-01

    Unlike in other fields of industrial radiography, where standard methods and procedures are used to control the quality of the radiographic image, no such standard exists for neutron radiography of nuclear fuel. To fill that gap it was felt that standardization work ought to be started in that field, too. Accordingly in 1979 an Euratom Neutron Radiography Working Group was constituted, which initiated standardization work in the field of neutron radiography of nuclear fuel. Finding adequate standards for image quality of neutron radiographs and checking the accuracy of dimension measurements from them were given first priority. (Auth.)

  8. Medical laboratories in sub-Saharan Africa that meet international quality standards.

    Science.gov (United States)

    Schroeder, Lee F; Amukele, Timothy

    2014-06-01

    A recent survey of laboratories in Kampala, Uganda, demonstrated that only 0.3% of laboratories (3/954) met international quality standards. To benchmark laboratory quality throughout the rest of sub-Saharan Africa (SSA), we compiled a list of SSA laboratories meeting international quality standards. Accrediting bodies were queried via online registries or direct communication in May 2013. There were 380 laboratories accredited to international standards in SSA. Ninety-one percent were in South Africa. Thirty-seven of 49 countries had no laboratories accredited to international quality standards. Accredited laboratory density (per million people) in South Africa, Namibia, and Botswana were similar to those in many European countries. Single variable linear regression showed a correlation between accredited laboratory density and health expenditures per person (adjusted R(2) = 0.81, P clinical laboratory. For those that do, there is a strong correlation between country-specific accredited laboratory density and per-capita health expenditures. Copyright© by the American Society for Clinical Pathology.

  9. Bread-Making Quality of Standard Winter Wheat Cultivars

    OpenAIRE

    Ćurić, Duška; Novotni, Dubravka; Bauman, Ingrid; Krička, Tajana; Jukić, Željko; Voća, Neven; Kiš, Darko

    2009-01-01

    The purpose of this study was to define an impact of the cultivar, year and cultivation area of the standard Croatian winter wheat on the bread-making quality. The bread-making quality of cultivars ‘Divana’, ‘Žitarka’ and ‘Sana’ from the crop years 1998, 2000, 2002, 2004 and 2006, and from Zagreb and Osijek location was analyzed. Wheat from the cultivar tests cultivated under the same agro technological conditions was used for this testing. The tested winter wheat bread-making quality primari...

  10. 42 CFR 493.1299 - Standard: Postanalytic systems quality assessment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Postanalytic systems quality assessment. 493.1299 Section 493.1299 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH....1291. (b) The postanalytic systems quality assessment must include a review of the effectiveness of...

  11. 42 CFR 493.1249 - Standard: Preanalytic systems quality assessment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Preanalytic systems quality assessment. 493.1249 Section 493.1249 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH....1241 through 493.1242. (b) The preanalytic systems quality assessment must include a review of the...

  12. The impact of laboratory quality assurance standards on laboratory operational performance

    Directory of Open Access Journals (Sweden)

    E Ratseou

    2014-01-01

    Full Text Available It has become a trend for companies to implement and be certified to various quality management systems so as to improve consistency, reliability, and quality of product delivery to customers. The most common quality management systems adopted are the ISO 9000 series of standards for manufacturing and services related organisations, with ISO 17025 and Good Laboratory Practices (GLP standards adopted specifically by laboratories as quality assurance initiatives. There are various reports on the impact of the ISO 9000 series on organisational performance but no studies or reports have been done on the performance of laboratory standards. Therefore this article reports on a study conducted to investigate the impact of ISO 17025 and GLP on the operational performance of both commercial and non-commercial laboratories. A qualitative research study was conducted to examine the impact standards on the aspects of health and safety, supplier selection and performance, human resources, customer satisfaction and profitability of the laboratory. The data collected suggest that there is no difference in laboratory operational performance with or without the standards. In other words it appears that the basic fundamental requirements inherent with laboratories are sufficient to perform both operationally and optimally. This leads to the view that standards are implemented as a customer requirement and not as an operational requirement.

  13. Quality standards: Comparison between IAEA 50-C/SG-Q and ISO 9001:2000

    International Nuclear Information System (INIS)

    2002-01-01

    The International Atomic Energy Agency (IAEA) has the statutory mandate to seek to accelerate and enlarge the contribution of atomic energy to peace, health and prosperity throughout the world. As part of the activities to achieve its objectives, the IAEA is authorized to establish standards of safety for the protection of health and the minimization of danger to life and property. The standards of safety developed by the IAEA are recommendations for use by its Member States in the framework of national regulations for the safe utilization of nuclear energy. Such standards should be considered as nuclear safety regulatory documents. The standards developed by the International Organization for Standardization (ISO) are complementary technical documents emphasizing industrial application and contractual aspects. Regarding the quality assurance topic, the IAEA developed the publication Safety Series No. 50-C/SG-Q, Quality Assurance for Safety in Nuclear Power Plants and other Nuclear Installations, which is mostly used directly or indirectly to establish the nuclear safety requirements at the nuclear utility-regulator interface. The ISO 9001:2000 standard, Quality Management Systems Requirements, is often used to define the quality management system requirements at the utility-supplier interface. The relationship between the IAEA and ISO quality standards is growing in significance owing to their increasing impact upon utilities (owners/operators of nuclear facilities) and their contractors/suppliers. The relationship between the IAEA and ISO standards is considered critical in particular with respect to contractors/suppliers with a small range of nuclear supplies. These contractors-suppliers are not always willing to prepare special quality assurance programmes based on nuclear safety standards. On the other hand, these contractors/suppliers may be qualified on the basis of the ISO quality standard. In any case, for delivering nuclear items and services the

  14. Minimum quality standards and international trade

    DEFF Research Database (Denmark)

    Baltzer, Kenneth Thomas

    2011-01-01

    This paper investigates the impact of a non-discriminating minimum quality standard (MQS) on trade and welfare when the market is characterized by imperfect competition and asymmetric information. A simple partial equilibrium model of an international Cournot duopoly is presented in which a domes...... prefer different levels of regulation. As a result, international trade disputes are likely to arise even when regulation is non-discriminating....

  15. 42 CFR 493.1289 - Standard: Analytic systems quality assessment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Analytic systems quality assessment. 493.1289 Section 493.1289 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND... through 493.1283. (b) The analytic systems quality assessment must include a review of the effectiveness...

  16. [Application of traditional Chinese medicine reference standards in quality control of Chinese herbal pieces].

    Science.gov (United States)

    Lu, Tu-Lin; Li, Jin-Ci; Yu, Jiang-Yong; Cai, Bao-Chang; Mao, Chun-Qin; Yin, Fang-Zhou

    2014-01-01

    Traditional Chinese medicine (TCM) reference standards plays an important role in the quality control of Chinese herbal pieces. This paper overviewed the development of TCM reference standards. By analyzing the 2010 edition of Chinese pharmacopoeia, the application of TCM reference standards in the quality control of Chinese herbal pieces was summarized, and the problems exiting in the system were put forward. In the process of improving the quality control level of Chinese herbal pieces, various kinds of advanced methods and technology should be used to research the characteristic reference standards of Chinese herbal pieces, more and more reasonable reference standards should be introduced in the quality control system of Chinese herbal pieces. This article discussed the solutions in the aspect of TCM reference standards, and future development of quality control on Chinese herbal pieces is prospected.

  17. Safety implications of standardized continuous quality improvement programs in community pharmacy.

    Science.gov (United States)

    Boyle, Todd A; Ho, Certina; Mackinnon, Neil J; Mahaffey, Thomas; Taylor, Jeffrey M

    2013-06-01

    Standardized continuous quality improvement (CQI) programs combine Web-based technologies and standardized improvement processes, tools, and expectations to enable quality-related events (QREs) occurring in individual pharmacies to be shared with pharmacies in other jurisdictions. Because standardized CQI programs are still new to community pharmacy, little is known about how they impact medication safety. This research identifies key aspects of medication safety that change as a result of implementing a standardized CQI program. Fifty-three community pharmacies in Nova Scotia, Canada, adopted the SafetyNET-Rx standardized CQI program in April 2010. The Institute for Safe Medication Practices (ISMP) Canada's Medication Safety Self-Assessment (MSSA) survey was administered to these pharmacies before and 1 year into their use of the SafetyNET-Rx program. The nonparametric Wilcoxon signed-rank test was used to explore where changes in patient safety occurred as a result of SafetyNETRx use. Significant improvements occurred with quality processes and risk management, staff competence, and education, and communication of drug orders and other information. Patient education, environmental factors, and the use of devices did not show statistically significant changes. As CQI programs are designed to share learning from QREs, it is reassuring to see that the largest improvements are related to quality processes, risk management, staff competence, and education.

  18. Standard setting and quality of assessment: A conceptual approach ...

    African Journals Online (AJOL)

    Quality performance standards and the effect of assessment outcomes are important in the educational milieu, as assessment remains the representative ... not be seen as a methodological process of setting pass/fail cut-off points only, but as a powerful catalyst for quality improvements in HPE by promoting excellence in ...

  19. Round table discussion: Quality control and standardization of nuclear medicine software

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    In summary the round table came to the following important conclusions: Nuclear medicine software systems need better documentation, especially regarding details of algorithms and limitations, and user friendliness could be considerably improved. Quality control of software is an integral part of quality assurance in nuclear medicine and should be performed at all levels of the software. Quality control of applications software should preferably be performed with assistance of generally accepted software phantoms. A basic form of standardization was welcomed and partly regarded as essential by all participants. Some areas such as patient study files could be standardized in the near future, whereas other areas such as the standardization of clinical applications programs or acquisition protocols still present major difficulties. An international cooperation in the field of standardization of software and other topics has already been started on the European level and should be continued and supported. (orig.)

  20. Requirements and standards facilitating quality improvement for reporting systems in gastrointestinal endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement

    NARCIS (Netherlands)

    Bretthauer, Michael; Aabakken, Lars; Dekker, Evelien; Kaminski, Michal F.; Rösch, Thomas; Hultcrantz, Rolf; Suchanek, Stepan; Jover, Rodrigo; Kuipers, Ernst J.; Bisschops, Raf; Spada, Cristiano; Valori, Roland; Domagk, Dirk; Rees, Colin; Rutter, Matthew D.

    2016-01-01

    To develop standards for high quality in gastrointestinal (GI) endoscopy, the European Society of Gastrointestinal Endoscopy (ESGE) has established the ESGE Quality Improvement Committee. A prerequisite for quality assurance and improvement for all GI endoscopy procedures is state-of-the-art

  1. EXPERT-ANALITICAL MONITORING OF LEARNING PROCESS QUALITY IN HIGH SCHOOL

    Directory of Open Access Journals (Sweden)

    T. M. Korotun

    2010-10-01

    Full Text Available The technological model is proposed for monitoring process of learning process quality in high school compliant with current European and home standards. The mathematical methods are elaborated for diverse activities as to learning process objects quality determination unified support. They self-consistently combine: automatic expert evaluation with Bayesian net and Value tree models; Delphi technique enhancement; best practices for education quality assessment. Quality estimates’ consistency index is introduced for their choice and acceptability analysis. Its permanent increasing over monitoring stages is guaranteed. The tools for these stages’ automatic support are described.

  2. Impact of model uncertainty on soil quality standards for cadmium in rice paddy fields

    International Nuclear Information System (INIS)

    Roemkens, P.F.A.M.; Brus, D.J.; Guo, H.Y.; Chu, C.L.; Chiang, C.M.; Koopmans, G.F.

    2011-01-01

    At present, soil quality standards used for agriculture do not consider the influence of pH and CEC on the uptake of pollutants by crops. A database with 750 selected paired samples of cadmium (Cd) in soil and paddy rice was used to calibrate soil to plant transfer models using the soil metal content, pH, and CEC or soil Cd and Zn extracted by 0.01 M CaCl 2 as explanatory variables. The models were validated against a set of 2300 data points not used in the calibration. These models were then used inversely to derive soil quality standards for Japonica and Indica rice cultivars based on the food quality standards for rice. To account for model uncertainty, strict soil quality standards were derived considering a maximum probability that rice exceeds the food quality standard equal to 10 or 5%. Model derived soil standards based on Aqua Regia ranged from less than 0.3 mg kg -1 for Indica at pH 4.5 to more than 6 mg kg -1 for Japonica-type cultivars in clay soils at pH 7. Based on the CaCl 2 extract, standards ranged from 0.03 mg kg -1 Cd for Indica cultivars to 0.1 mg kg -1 Cd for Japonica cultivars. For both Japonica and Indica-type cultivars, the soil quality standards must be reduced by a factor of 2 to 3 to obtain the strict standards. The strong impact of pH and CEC on soil quality standards implies that it is essential to correct for soil type when deriving national or local standards. Validation on the remaining 2300 samples indicated that both types of models were able to accurately predict (> 92%) whether rice grown on a specific soil will meet the food quality standard used in Taiwan. - Research highlights: → Cadmium uptake by Japonica and Indica rice varieties depends on soil pH and CEC. → Food safety based soil standards range from 0.3 (Indica) to 6 mg kg -1 (Japonica). → Model uncertainty leads to strict soil standards of less than 0.1 mg kg -1 for Indica. → Soil pH and CEC should be considered to obtain meaningful standards for agriculture.

  3. 78 FR 58500 - Water Quality Standards Regulatory Clarifications Proposed Rule; Public Meeting and Public Webinars

    Science.gov (United States)

    2013-09-24

    ... the proposed rule ``Water Quality Standards Regulatory Clarifications,'' which was published... the federal water quality standards (WQS) regulation at 40 CFR Part 131 which helps implement the..., the proposed rule will lead to improved water quality standard development, implementation and...

  4. Quality leadership skills Standards of Leadership Behavior

    CERN Document Server

    Leatherman, Richard W

    2008-01-01

    Would you like to really know how to empower employees to take greater charge over their careers? To teach employees how to take more responsibility for their performance appraisals? To delegate work to employees? You'll get clear direction in Quality Leadership - a practical manual that addresses today's need for quality performance and gives techniques for handling a wide array of employee problems. This how-to-do-it resource for new and future leaders explains basic leadership tasks in a simple, step-by-step manner. It is full of practical advice - not theories - and outlines clear standard

  5. 42 CFR 440.260 - Methods and standards to assure quality of services.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Methods and standards to assure quality of services. 440.260 Section 440.260 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH... and Limits Applicable to All Services § 440.260 Methods and standards to assure quality of services...

  6. 40 CFR 131.8 - Requirements for Indian Tribes to administer a water quality standards program.

    Science.gov (United States)

    2010-07-01

    ... administer a water quality standards program. 131.8 Section 131.8 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY STANDARDS General Provisions § 131.8 Requirements for Indian Tribes to administer a water quality standards program. (a) The Regional Administrator, as...

  7. INCITS W1.1 development update: appearance-based image quality standards for printers

    Science.gov (United States)

    Zeise, Eric K.; Rasmussen, D. René; Ng, Yee S.; Dalal, Edul; McCarthy, Ann; Williams, Don

    2008-01-01

    In September 2000, INCITS W1 (the U.S. representative of ISO/IEC JTC1/SC28, the standardization committee for office equipment) was chartered to develop an appearance-based image quality standard. (1),(2) The resulting W1.1 project is based on a proposal (3) that perceived image quality can be described by a small set of broad-based attributes. There are currently six ad hoc teams, each working towards the development of standards for evaluation of perceptual image quality of color printers for one or more of these image quality attributes. This paper summarizes the work in progress of the teams addressing the attributes of Macro-Uniformity, Colour Rendition, Gloss & Gloss Uniformity, Text & Line Quality and Effective Resolution.

  8. Impact of model uncertainty on soil quality standards for cadmium in rice paddy fields

    Energy Technology Data Exchange (ETDEWEB)

    Roemkens, P.F.A.M., E-mail: paul.romkens@wur.nl [Soil Science Center, Alterra, WageningenUR. P.O. Box 47, 6700AA Wageningen (Netherlands); Brus, D.J. [Soil Science Center, Alterra, WageningenUR. P.O. Box 47, 6700AA Wageningen (Netherlands); Guo, H.Y.; Chu, C.L.; Chiang, C.M. [Taiwan Agricultural Research Institute (TARI), Wufong, Taiwan (China); Koopmans, G.F. [Soil Science Center, Alterra, WageningenUR. P.O. Box 47, 6700AA Wageningen (Netherlands); Department of Soil Quality, Wageningen University, WageningenUR. P.O. Box 47, 6700AA, Wageningen (Netherlands)

    2011-08-01

    At present, soil quality standards used for agriculture do not consider the influence of pH and CEC on the uptake of pollutants by crops. A database with 750 selected paired samples of cadmium (Cd) in soil and paddy rice was used to calibrate soil to plant transfer models using the soil metal content, pH, and CEC or soil Cd and Zn extracted by 0.01 M CaCl{sub 2} as explanatory variables. The models were validated against a set of 2300 data points not used in the calibration. These models were then used inversely to derive soil quality standards for Japonica and Indica rice cultivars based on the food quality standards for rice. To account for model uncertainty, strict soil quality standards were derived considering a maximum probability that rice exceeds the food quality standard equal to 10 or 5%. Model derived soil standards based on Aqua Regia ranged from less than 0.3 mg kg{sup -1} for Indica at pH 4.5 to more than 6 mg kg{sup -1} for Japonica-type cultivars in clay soils at pH 7. Based on the CaCl{sub 2} extract, standards ranged from 0.03 mg kg{sup -1} Cd for Indica cultivars to 0.1 mg kg{sup -1} Cd for Japonica cultivars. For both Japonica and Indica-type cultivars, the soil quality standards must be reduced by a factor of 2 to 3 to obtain the strict standards. The strong impact of pH and CEC on soil quality standards implies that it is essential to correct for soil type when deriving national or local standards. Validation on the remaining 2300 samples indicated that both types of models were able to accurately predict (> 92%) whether rice grown on a specific soil will meet the food quality standard used in Taiwan. - Research highlights: {yields} Cadmium uptake by Japonica and Indica rice varieties depends on soil pH and CEC. {yields} Food safety based soil standards range from 0.3 (Indica) to 6 mg kg{sup -1} (Japonica). {yields} Model uncertainty leads to strict soil standards of less than 0.1 mg kg{sup -1} for Indica. {yields} Soil pH and CEC should be

  9. [Study on quality standard of Mucuna pruriens var. utilis].

    Science.gov (United States)

    Wu, Shi-Hong; Jiang, Wei-Zhe; Lv, Li; Wu, Ling-Ling; Lv, Cong; Shi, Xiao-Xia; Su, Gui-Liang

    2009-03-01

    To provide scientific basis for the utilization and development of Mucuna pruriens var. utilis by establishing its quality control standard. The bioactive constituents were analyzed by TLC and HPLC. Moisture, ash and the extracts of Mucuna pruriens var. utilis were all determined. The TLC spots of levodopa had similar color with the control group at the same position. The results of HPLC quantitative analysis showed that the linear range of levodopa was 26.45 to approximately 132.25 microg/mL, r = 0.9992, and the average recovery rate was 103.8%, RSD = 1.85%. This method is convenient, accurate, reliable with good reproducibility, so it can be used to establish quality standard for the medicinal material.

  10. Brief review of German standards for quality audits in automotive production

    Directory of Open Access Journals (Sweden)

    Yulia Šurinová

    2013-04-01

    Full Text Available Quality management systems (QMS in the automotive industry have several differences in comparison with other industrial factories. Each customer has his own specific requirements, the so-called CSRs (Customer Specific Requirements. Audits are one of the core-tools of quality management to make the PDCA cycle work. It is clear that compliance to ISO/TS 16949:2009 requirements is a condition for supplying the automotive industry. But there are some standards which co-exist together with the official ISO9001 Q-management systems standards and technical specification ISO/TS16949. What are those specific standards in the automotive industry and which standard should be used and why – those are the questions to be answered in this article.

  11. Developing quality standards for physical properties of mineral wool plugs

    NARCIS (Netherlands)

    Blok, C.; Berg, van den C.C.; Winkel, van A.

    2014-01-01

    The KIWA certification guidelines for mineral wool products contain standards for slabs and blocks. Propagators would like to introduce quality standards for mineral wool plugs as well. Main concerns were effects of too dense plugs on plant growth, and handling problems with too fluffy or broken

  12. Image quality assesment using NEMA NU 4/2008 standards in small animal PET scanner

    International Nuclear Information System (INIS)

    Gontijo, Rodrigo M.G.; Ferreira, Andréa V.; Silva, Juliana B.; Mamede, Marcelo

    2017-01-01

    In Brazil, there are few micro PET in use and a quality control protocols standardization are needed to harmonize their use in the research field. Thus, the purpose of this study is to characterize the image quality performance of the micro PET scanner (Lab PET 4, GE healthcare Technologies, Waukesha, WI) using the NEMA NU 4/ 2008 standards and specific phantom. The NEMA image-quality (IQ) phantom consists of 3 different regions to analyze distinct characteristics: image noise (%SD), expressed as percentage SD in a uniform region (%SD), recovery coefficient (RC) and Spill-over (SOR) in air and water. The IQ phantom was filled with 18 F-FDG calibrated at the beginning of acquisition, placed in the center of the field-of-view (FOV) and measured with the typical whole body imaging protocol. The images were reconstructed with different reconstruction methods (FBP-2D; MLEM-3D and OSEM-3D); with and without high resolution (HR) when possible. The results were compared. The LabPET 4 system produces appropriate image and with performance according to the literature. The present study is an initial step to verify the NEMA NU 4/2008 use in the Brazilian scenario for further standardization. (author)

  13. Image quality assesment using NEMA NU 4/2008 standards in small animal PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    Gontijo, Rodrigo M.G.; Ferreira, Andréa V.; Silva, Juliana B.; Mamede, Marcelo, E-mail: rodrigo.gontijo@cdtn.br, E-mail: rodrigogadelhagontijo1@hotmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    In Brazil, there are few micro PET in use and a quality control protocols standardization are needed to harmonize their use in the research field. Thus, the purpose of this study is to characterize the image quality performance of the micro PET scanner (Lab PET 4, GE healthcare Technologies, Waukesha, WI) using the NEMA NU 4/ 2008 standards and specific phantom. The NEMA image-quality (IQ) phantom consists of 3 different regions to analyze distinct characteristics: image noise (%SD), expressed as percentage SD in a uniform region (%SD), recovery coefficient (RC) and Spill-over (SOR) in air and water. The IQ phantom was filled with {sup 18}F-FDG calibrated at the beginning of acquisition, placed in the center of the field-of-view (FOV) and measured with the typical whole body imaging protocol. The images were reconstructed with different reconstruction methods (FBP-2D; MLEM-3D and OSEM-3D); with and without high resolution (HR) when possible. The results were compared. The LabPET 4 system produces appropriate image and with performance according to the literature. The present study is an initial step to verify the NEMA NU 4/2008 use in the Brazilian scenario for further standardization. (author)

  14. Quality of Standard Reference Materials for Short Time Activation Analysis

    International Nuclear Information System (INIS)

    Ismail, S.S.; Oberleitner, W.

    2003-01-01

    Some environmental reference materials (CFA-1633 b, IAEA-SL-1, SARM-1,BCR-176, Coal-1635, IAEA-SL-3, BCR-146, and SRAM-5) were analysed by short-time activation analysis. The results show that these materials can be classified in three groups, according to their activities after irradiation. The obtained results were compared in order to create a quality index for determination of short-lived nuclides at high count rates. It was found that Cfta is not a suitable standard for determining very short-lived nuclides (half-lives<1 min) because the activity it produces is 15-fold higher than that SL-3. Biological reference materials, such as SRM-1571, SRM-1573, SRM-1575, SRM-1577, IAEA-392, and IAEA-393, were also investigated by a higher counting efficiency system. The quality of this system and its well-type detector for investigating short-lived nuclides was discussed

  15. 38 CFR 17.155 - Minimum standards of safety and quality for automotive adaptive equipment.

    Science.gov (United States)

    2010-07-01

    ... safety and quality for automotive adaptive equipment. 17.155 Section 17.155 Pensions, Bonuses, and... Minimum standards of safety and quality for automotive adaptive equipment. (a) The Under Secretary for... officials that it meets implicit standards of safety and quality adopted by the industry or as later...

  16. Respect of standard air quality in major italian towns

    International Nuclear Information System (INIS)

    Valerio, F.

    1995-01-01

    In 1983 air quality standards, related to SO 2 , NO 2 , CO, airborne particulate, lead, O 3 were introduced in italian legislation. Now, SO 2 and lead concentrations are rapidly decreasing everywhere thanks to drastic reductions of sulphur and lead in fuels. The situation is still critic in many urban areas as far as NO 2 and CO are concerned. The increasing number of automobiles circulating in italian urban areas (+43% from 1980 to 1988) is probably reducing the positive effects expected from more efficient and less polluting engines. Electric public transport, aiming at low interference with private traffic, and a different urban organization, aiming at reducing compulsory mobility, could be the proper choices to offer italians both higher standards of urban life and air quality

  17. Extent of Implementing Accreditation and Quality Assurance Standards in Azal University of Human Development from the Faculty Members’ Perspective

    Directory of Open Access Journals (Sweden)

    Mohammed Zain Saleh ALSadi

    2017-10-01

    Full Text Available The research aimed to find out how far accreditation and quality assurance standards in Azal University for human development are implemented from the perspective of faculty members. To achieve this objective, to the researchers adopted descriptive analytical approach techniques. The research population was all the teaching staff at the university; and the sample consisted of (94 faculty members, (48.45 % of the total number of the population. A questionnaire was designed to collect data relevant to the testing of the research objectives. The questionnaire consisted of two parts: the first included the personal data, while the second part included the standards of accreditation and quality assurance. The study revealed the following results: The mean of implementing standards as a whole was (3.44, the standard deviation (0.76, and the extent of the using the standards was (high. There were no significant differences between the research participants’ responses about the extent of using the standards due to the variables (gender – Qualification – college type – years of teaching experience. In light of the results of the study, a set of recommendations were presented, including the need to provide the necessary requirements for implementing accreditation and quality assurance standards, whether material, human or financial resources, and creating a positive conducive learning environment to be suitable and ready for a complete implementation of quality standards. One of the main suggestions made by the research was to conduct a similar study on government and private universities and community colleges in Yemen. Keywords: Quality Assurance and accreditation; Azal University of Human Development.

  18. Automotive standard ISO/TS 16949 as a quality determinant

    Directory of Open Access Journals (Sweden)

    Joanna Rosak-Szyrocka

    2016-03-01

    Full Text Available The main aim of this paper is to present the standard ISO/TS 16949. In the modern world of competition, quality is one of the most important factors. Modern organizations should gamble on quality, regardless of the type of business, because it is the basic form of running a business effectively. It is not only a factor of market success, but also an indication of organizational culture.

  19. The role of Health Impact Assessment in the setting of air quality standards: An Australian perspective

    Energy Technology Data Exchange (ETDEWEB)

    Spickett, Jeffery, E-mail: J.Spickett@curtin.edu.au [WHO Collaborating Centre for Environmental Health Impact Assessment (Australia); Faculty of Health Sciences, School of Public Health, Curtin University, Perth, Western Australia (Australia); Katscherian, Dianne [WHO Collaborating Centre for Environmental Health Impact Assessment (Australia); Faculty of Health Sciences, School of Public Health, Curtin University, Perth, Western Australia (Australia); Harris, Patrick [CHETRE — UNSW Research Centre for Primary Health Care and Equity, University of New South Wales (Australia)

    2013-11-15

    The approaches used for setting or reviewing air quality standards vary from country to country. The purpose of this research was to consider the potential to improve decision-making through integration of HIA into the processes to review and set air quality standards used in Australia. To assess the value of HIA in this policy process, its strengths and weaknesses were evaluated aligned with review of international processes for setting air quality standards. Air quality standard setting programmes elsewhere have either used HIA or have amalgamated and incorporated factors normally found within HIA frameworks. They clearly demonstrate the value of a formalised HIA process for setting air quality standards in Australia. The following elements should be taken into consideration when using HIA in standard setting. (a) The adequacy of a mainly technical approach in current standard setting procedures to consider social determinants of health. (b) The importance of risk assessment criteria and information within the HIA process. The assessment of risk should consider equity, the distribution of variations in air quality in different locations and the potential impacts on health. (c) The uncertainties in extrapolating evidence from one population to another or to subpopulations, especially the more vulnerable, due to differing environmental factors and population variables. (d) The significance of communication with all potential stakeholders on issues associated with the management of air quality. In Australia there is also an opportunity for HIA to be used in conjunction with the NEPM to develop local air quality standard measures. The outcomes of this research indicated that the use of HIA for air quality standard setting at the national and local levels would prove advantageous. -- Highlights: • Health Impact Assessment framework has been applied to a policy development process. • HIA process was evaluated for application in air quality standard setting.

  20. Quality Management Systems And Impact From Standardization In Albanian Companies

    Directory of Open Access Journals (Sweden)

    Ira Zoga Gjika

    2015-08-01

    Full Text Available The increase of competition in the local and regional markets is forcing companies to provide high quality products and services as well as to continuously improve their activities. The quality management systems and standard implementation in Albanian companies are the at the focus of this paper with the intention to evidence the actual situation and the results achieved from the certification process. The implementation of ISO standard requirements together with the assessment of the benefits deriving from it is a relatively new experience for Albanian companies and slightly developed in our economic literature. Consequently this work follows a combined approach of reviewing the relevant rich literature of the last decades with the empirical survey of some Albanian companies that have chosen ISO certification as an instrument to gain competitive advantage in the market. The analysis of factors that drive companies towards such time consuming costly and managerially- wise committed process is one of main study objectives. It is followed by the assessment of benefits deriving from this process for companies in quantitative and qualitative terms. Comparing the expected advantages from the certification with those actually obtained might assist companies themselves to improve their processes. From the other side this comparison serves as a basis for suggestions and recommendations to other companies that intend to make good use of advantages the ISO certification.

  1. Standards and laws for indoor air quality in Russia

    International Nuclear Information System (INIS)

    Bitkolov, N.; Musijchuk, Y.

    1997-01-01

    The air quality of indoor air in Russia, including the special problems of air quality with regard to radioactive contamination, is determined by a number of statutes, standards and regulations. All these are based on the biological principles that the maximum allowable concentrations of pollutants (MAC) and the prescribed radioactive safety dose limits should not be exceeded. The standards cover the air in the working zones of all ministries and departments, and are for trade unions, public and cooperative organisations and foundations. The basic Russian law for air quality is 'The Law on Environmental Nature Protection' (19.2.1991) which assures the right to health protection from adverse environmental effects. In the field of radioactive safety 'The Federal Law on Radioactive Safety' (9.1.1996) is the primary law and in accordance with it, every citizen living in Russia has the right to protection for the present and future generations from health-related deleterious effects of atomic radiation. The laws on air quality are part of the Russian Federation legal system and are secured in the Constitution. The air quality must be controlled by the Goscomgidromet and the Sunepidnadzor of Russia. In compliance with these laws everybody has the right to a favourable environment and the duty to protect, preserve and maintain it. The air environment is unique and common to all, thus economic cooperation dictates that a dedicated approach to air quality and air quality regulations would be the most appropriate way to preserve it. It appears judicious to join forces in the name of European ecological safety. To do this, it is necessary to combine the national means and secure. (author) 4 figs

  2. Reducing the risk of failure: Software Quality assurance standards and methods

    International Nuclear Information System (INIS)

    Elphick, J.; Cope, H.

    1992-01-01

    An effective Software Quality Assurance (SQA) program provides an overall approach to software engineering and the establishment of proven methods for the production of reliable software. And, in the authors experience, the overall costs for the software life are diminished with the application of quality methods. In their experience, the issues for implementing quality standards and practices are many. This paper addresses those issues as well as the lessons learned from developing and implementing a number of software quality assurance programs. Their experience includes the development and implementation of their own NRC accepted SQA program and an SQA program for an engineering software developer, as well as developing SQA procedures, standards, and methods for utilities, medical and commercial clients. Some of the issues addressed in this paper are: setting goals and defining quality; applying the software life cycle; addressing organizational issues; providing flexibility and increasing productivity; producing effective documentation; maintaining quality records; Imposing software configuration management; conducting reviews, audits, and controls; verification and validation; and controlling software procurement

  3. The Nencki Affective Picture System (NAPS): introduction to a novel, standardized, wide-range, high-quality, realistic picture database.

    Science.gov (United States)

    Marchewka, Artur; Zurawski, Łukasz; Jednoróg, Katarzyna; Grabowska, Anna

    2014-06-01

    Selecting appropriate stimuli to induce emotional states is essential in affective research. Only a few standardized affective stimulus databases have been created for auditory, language, and visual materials. Numerous studies have extensively employed these databases using both behavioral and neuroimaging methods. However, some limitations of the existing databases have recently been reported, including limited numbers of stimuli in specific categories or poor picture quality of the visual stimuli. In the present article, we introduce the Nencki Affective Picture System (NAPS), which consists of 1,356 realistic, high-quality photographs that are divided into five categories (people, faces, animals, objects, and landscapes). Affective ratings were collected from 204 mostly European participants. The pictures were rated according to the valence, arousal, and approach-avoidance dimensions using computerized bipolar semantic slider scales. Normative ratings for the categories are presented for each dimension. Validation of the ratings was obtained by comparing them to ratings generated using the Self-Assessment Manikin and the International Affective Picture System. In addition, the physical properties of the photographs are reported, including luminance, contrast, and entropy. The new database, with accompanying ratings and image parameters, allows researchers to select a variety of visual stimulus materials specific to their experimental questions of interest. The NAPS system is freely accessible to the scientific community for noncommercial use by request at http://naps.nencki.gov.pl .

  4. National BTS bronchiectasis audit 2012: is the quality standard being adhered to in adult secondary care?

    Science.gov (United States)

    Hill, Adam T; Routh, Chris; Welham, Sally

    2014-03-01

    A significant step towards improving care of patients with non-cystic fibrosis bronchiectasis was the creation of the British Thoracic Society (BTS) national guidelines and the quality standard. A BTS bronchiectasis audit was conducted between 1 October and 30 November 2012, in adult patients with bronchiectasis attending secondary care, against the BTS quality standard. Ninety-eight institutions took part, submitting a total of 3147 patient records. The audit highlighted the variable adoption of the quality standard. It will allow the host institutions to benchmark against UK figures and drive quality improvement programmes to promote the quality standard and improve patient care.

  5. Standards - the common element in providing the safety, quality and performance of the medical practice

    Science.gov (United States)

    Greabu, Mihai

    2009-01-01

    Knowing and applying standards is an opportunity of the years 2007-2008 in any kind of field where a successful activity is intended and this assures a certain way towards competence and quality. The most recent German studies highlighted, to the surprise of the specialists, that standardization holds the second place, after the material means, in the row of the elements considered to be decisive for the success of a business. The existence of standards and the concern for their implementation in the activity provides a high technical and quality level of the products services offered to the clients and the increase in the level of competence of the personnel, who will be able to cope with all the challenges. This need comes from the process of Romania’s accession to the European Union. There are a lot of reasons why standards represent a fundamental part of our daily life. Practically, we are surrounded by standards. Everything is „working” well and it is efficient if the standards used as a base for manufacturing „things” have been correctly developed and applied. Standards open communication channels and commercial channels, promote the understanding of technical products, the compatibility of products and services, facilitate mass production and, most importantly, they are the necessary base for the achievement of the objectives in the fields of health and safety and a better quality of life. The transition towards the global market needs an instrument for the removal of the barriers to the application of the latest discoveries in the field of medical instruments, materials and manual labor. Each medical device, equipment and material used in the Dental and General Medicine is standardized, in fact that leads to their better knowing and provides controllable treatment for manual labor with predictable and repeatable results. This presentation intends to make a survey of some general aspects on standardization as well as a review of the standards in

  6. Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267

    International Nuclear Information System (INIS)

    Correa, Eduardo de Lima

    2010-01-01

    In this work it was developed and applied a quality control program of the X radiation system (160 kV, constant potential, target of tungsten) of the Calibration Laboratory of IPEN(LCI) in the energy range relative to mammography beams (from 25 kV to 35 kV). The X radiation standards beams, level mammography, using molybdenum and aluminum as additional filtration, were established after the application of this quality control program following national and international recommendations. The reference ionization chamber has traceability to PTB and was regularly submitted to quality control tests for evaluation and analysis of its performance. The radiation qualities emerging from the X-radiation assembly (RQR-M), based on a phantom made up of an aluminum added filter (RQA-M), narrow beam condition (RQN-M) and broad beam condition (RQB-M), following the recommendations of the international standard IEC 61267 (2005) and the IAEA code of practice, TRS 457 (2007) were established. For the implantation of RQN-M and RQB-M radiation qualities, two mammography phantoms were developed. The half-value layers found are those presented by the German primary laboratory PTB, and varied from 0.35 to 1.21 mm Al. The air kerma rates were obtained for all the 15 implanted qualities. (author)

  7. 76 FR 76048 - Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards

    Science.gov (United States)

    2011-12-06

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 81 [EPA-HQ-OAR-2009-0443; FRL-9492-3] RIN 2060-AR17 Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards Correction In rule document 2011-29460 appearing on pages 72097-72120 in the issues of Tuesday, November 22, 2011...

  8. Standard Practice for Quality Management Systems for Nondestructive Testing Agencies

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers general requirements for the establishment and maintenance of a quality management system for agencies engaged in nondestructive testing (NDT). 1.2 This practice utilizes criteria contained in Practice E 543. 1.3 This practice utilizes criteria contained in American National Standard ANSI/ISO/ASQ Q9001–2000, Quality management systems—Requirements. 1.4 This practice recognizes the importance of establishing minimum safety criteria. 1.5 The use of SI or inch-pound units, or combinations thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.6 This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this practice to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Safety and quality management at the high flux reactor Petten

    International Nuclear Information System (INIS)

    Zurita, A.; Ahlf, J.

    1995-01-01

    The High Flux Reactor (HFR) is one high power multi-purpose materials testing research reactor of the tank-in-pool type, cooled and moderated by light-water. It is operated at 45 MW at a prescribed schedule of 11 cycles per year, each comprising 25 operation days and three shut-down days. Since the licence for the operation of HFR was granted in 1962, a total of 14 amendments to the original licence have been made following different modifications in the installations. In the meantime, international nuclear standards were developed, especially in the framework of the NUSS programme of the IAEA, which were adopted by the Dutch Licensing Authorities. In order to implement the new standards, the situation at the HFR was comprehensively reviewed in the course of an audit performed by the Dutch Licensing Authorities in 1988. This also resulted in formulating the task of setting-up an 'HFR - Integral Quality Assurance Handbook' (HFR-IQAD) involving both organizations JRCIAM and ECN, which had the unique framework and basic guideline to assure the safe and efficient operation and exploitation of the HFR and to promote safety and quality in all aspects of HFR related activities. The assurance of safe and efficient operation and exploitation of the HFR is condensed together under the concepts of safety and quality of services and is achieved through the safety and quality management. (orig.)

  10. Carbon finance and pro-poor co-benefits: The Gold Standard and Climate, Community and Biodiversity Standards

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Rachel

    2011-04-15

    This paper assesses the practical contribution of the Gold Standard (GS) and Climate Community and Biodiversity (CCB) Standards to local development through the identification of high quality carbon offset projects and ensuring high standards of consultation with local communities during project development and implementation. It is based on desk research, involving analysis of the GS and CCB Standards' project databases, project design documents, and secondary literature. In addition, over 20 representatives of the two standards systems, project developers, NGO representatives, and researchers were interviewed. The paper concludes that both standard systems successfully reward high quality projects which have a demonstrated commitment to local consultations and sustainable development benefits. Moreover, they serve to give well-meaning project developers frameworks with which to ensure that a wide range of criteria are considered in planning and implementing projects. As voluntary standards, it is unrealistic to expect either the GS or CCB Standards to improve poor-quality or unsustainable projects.

  11. Carbon finance and pro-poor co-benefits: The Gold Standard and Climate, Community and Biodiversity Standards

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Rachel

    2011-04-15

    This paper assesses the practical contribution of the Gold Standard (GS) and Climate Community and Biodiversity (CCB) Standards to local development through the identification of high quality carbon offset projects and ensuring high standards of consultation with local communities during project development and implementation. It is based on desk research, involving analysis of the GS and CCB Standards' project databases, project design documents, and secondary literature. In addition, over 20 representatives of the two standards systems, project developers, NGO representatives, and researchers were interviewed. The paper concludes that both standard systems successfully reward high quality projects which have a demonstrated commitment to local consultations and sustainable development benefits. Moreover, they serve to give well-meaning project developers frameworks with which to ensure that a wide range of criteria are considered in planning and implementing projects. As voluntary standards, it is unrealistic to expect either the GS or CCB Standards to improve poor-quality or unsustainable projects.

  12. BRC/IoP standard importance in packaging quality assurance

    Directory of Open Access Journals (Sweden)

    Agnieszka Kawecka

    2014-10-01

    Full Text Available BRC/IoP (British Retail Consortium / Institute of Packaging is the only industry standard dedicated entrepreneurs operating in the packaging industry, primarily intended for contact with food. The requirements of the BRC / IoP guarantee the safety of packaging and fulfillment of all legal and hygienic requirements. The article presents the main features of the standard, the basic requirements contained in the document and the results of research on the implementation of quality management systems, including standard BRC / IoP and the actions that are required checklists. It is noticeable that there is little interest in certification BRC / IoP, due to low awareness of the standard, despite the fulfillment of some of the basic requirements of the surveyed companies.

  13. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 2

    International Nuclear Information System (INIS)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction

  14. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction.

  15. Experimental investigation on water quality standard of Yangtze River water source heat pump.

    Science.gov (United States)

    Qin, Zenghu; Tong, Mingwei; Kun, Lin

    2012-01-01

    Due to the surface water in the upper reaches of Yangtze River in China containing large amounts of silt and algae, high content of microorganisms and suspended solids, the water in Yangtze River cannot be used for cooling a heat pump directly. In this paper, the possibility of using Yangtze River, which goes through Chongqing, a city in southwest China, as a heat source-sink was investigated. Water temperature and quality of the Yangtze River in the Chongqing area were analyzed and the performance of water source heat pump units in different sediment concentrations, turbidity and algae material conditions were tested experimentally, and the water quality standards, in particular surface water conditions, in the Yangtze River region that adapt to energy-efficient heat pumps were also proposed. The experimental results show that the coefficient of performance heat pump falls by 3.73% to the greatest extent, and the fouling resistance of cooling water in the heat exchanger increases up to 25.6% in different water conditions. When the sediment concentration and the turbidity in the river water are no more than 100 g/m3 and 50 NTU respectively, the performance of the heat pump is better, which can be used as a suitable river water quality standard for river water source heat pumps.

  16. Stability of Working Reference Standards for Hybrid K-Edge Densitometer Quality Assurance

    International Nuclear Information System (INIS)

    Guzzardo, T.; Pickett, C.A.; McElroy, R.; Croft, S.; Garrison, J.; Venkataraman, R.

    2015-01-01

    The relatively short working life of aqueous solution standards of actinides for the calibration and quality control of Hybrid K-Edge Densitometer (HKED) measurements necessitates the development of a stable matrix material less susceptible to degradation. Degradation in the form of evaporation, radiolysis, settling, sloshing, and sediment formation can all reduce the reliability and working life of an aqueous standard. These factors make aqueous solutions inadequate for long-term quality assurance measurements designed to detect weak or subtle trends in system performance. Epoxy, studied here, is an alternative matrix material that may be less vulnerable to degradation. An additional benefit of epoxy is that standards can easily be characterized as sealed sources which allows for simplified administrative controls during shipping and storage. The stability of working reference standards consisting of U 3 O 8 in an epoxy matrix for use in the HKED has been tracked for over three years through repeated X-ray Fluorescence (XRF) and K-Edge (KED) measurements. A set of six epoxy standards ranging in concentration from 1 g/l to 76 g/l uranium were determined to be stable, within the expected accuracy of the system, over the period of analysis. During this time, no effort was made to enhance the stability of the epoxy standards; the radial measurement position was not controlled and in the middle of the analysis period the HKED system and standards were shipped from the vendor's factory to the customer. Epoxy standards afford numerous benefits over those created from aqueous solutions and should be considered when developing HKED standards for quality assurance measurements. The stability of the epoxy allows the development of working standards of a stability and robustness sufficient for use in a proposed international round-robin exercise based on the exchange of such standards. (author)

  17. Revision of the ASME nuclear quality assurance standard and its historical background

    International Nuclear Information System (INIS)

    Suzuki, Tetsuya

    2009-01-01

    ASME NQA-1-2008 'Quality Assurance Requirements for Nuclear Facility Applications' will be endorsed by US NRC by the end of 2009. This standard will apply to design, construction and operation of nuclear power plants newly erected in USA. It is important to Japanese vendors developing nuclear business in USA. Historical background, significance of revision and main revised points of the ASME nuclear quality assurance standard are described in the present paper. (T. Tanaka)

  18. Quality assurance standards: comparison between IAEA 50-C/SG-Q and ISO 9001:1994

    International Nuclear Information System (INIS)

    2000-11-01

    The International Atomic Energy Agency (IAEA) and the International Organization for Standardization (ISO) agreement regarding the scope and coverage of documents published by both organizations points out that the standards of safety developed by the IAEA are recommendations for use by its Member States in the framework of national regulations for the safe utilization of nuclear energy. Such standards should be considered as nuclear safety regulatory documents. The standards developed by the ISO are complementary technical documents emphasizing industrial application and contractual aspects. Regarding the quality assurance topic, the IAEA standards 50-C/SG-Q are mostly used directly or indirectly to establish the nuclear safety requirements at the utility-regulatory interface. The industrial ISO 9001 standards have progressively been used to implement the quality assurance requirements at the interface utility-supplier. The relationship between both standards is growing in significance owing to the impact upon the owners/operators of nuclear facilities and their contractors/suppliers. The relationship between the IAEA and ISO standards is considered critical, in particular regarding suppliers with a small range of nuclear supplies. These organizations are not always willing to prepare special quality assurance programmes based on nuclear safety standards. On the other hand, these organizations may be qualified on the basis of the ISO quality assurance standards. In any case, for delivering nuclear items and services the quality assurance programme must comply with the requirements established in the nuclear safety regulatory standards. This implies that the utility-supplier will have to demonstrate that the acceptable degree of quality assurance in relation to nuclear safety is accomplished. This may be achieved by imposing additional requirements on the supplier over and above those contained within the ISO. In order to provide a description of the differences

  19. Constructing Assessment Model of Primary and Secondary Educational Quality with Talent Quality as the Core Standard

    Science.gov (United States)

    Chen, Benyou

    2014-01-01

    Quality is the core of education and it is important to standardization construction of primary and secondary education in urban (U) and rural (R) areas. The ultimate goal of the integration of urban and rural education is to pursuit quality urban and rural education. Based on analysing the related policy basis and the existing assessment models…

  20. The health benefits of attaining and strengthening air quality standards in Cape Town

    Directory of Open Access Journals (Sweden)

    Samantha Keen

    2016-12-01

    Full Text Available The link between pollution and poor health and mortality has been established globally. Developing countries carry most of the burden of ill health from air pollution, and urban centres like the City of Cape Town even more so. Effective air quality management to protect human health relies on the attainment of air quality standards. This study uses the Benefits Mapping and Analysis Program (BenMAP along with a locally derived exposure-response function and air quality monitor data to investigate whether the consistent attainment of current or more stringent air quality standards would avoid loss of life. The results show that attaining the PM10 24-hour mean South Africa National Standard limit and the PM10 and SO2 24-hour mean World Health Organisation guidelines in Cape Town reduces levels of pollutants and does reduce excess risk of mortality in Cape Town.

  1. A Risk and Standards Based Approach to Quality Assurance in Australia's Diverse Higher Education Sector

    Science.gov (United States)

    Australian Government Tertiary Education Quality and Standards Agency, 2015

    2015-01-01

    The Australian Government Tertiary Education Quality and Standards Agency's (TEQSA's) role is to assure that quality standards are being met by all registered higher education providers. This paper explains how TEQSA's risk-based approach to assuring higher education standards is applied in broad terms to a diverse sector. This explanation is…

  2. 75 FR 4173 - Water Quality Standards for the State of Florida's Lakes and Flowing Waters

    Science.gov (United States)

    2010-01-26

    ... Part III Environmental Protection Agency 40 CFR Part 131 Water Quality Standards for the State of...-HQ-OW-2009-0596; FRL-9105-1] RIN 2040-AF11 Water Quality Standards for the State of Florida's Lakes... Environmental Protection Agency (EPA) is proposing numeric nutrient water quality criteria to protect aquatic...

  3. Requirements for a quality measurement instrument for semantic standards

    NARCIS (Netherlands)

    Folmer, E.J.A.; Krukkert, D.; Oude Luttighuis, P.; Hillegersberg van, J. van

    2010-01-01

    This study describes requirements for an instrument to measure the quality of semantic standards. A situational requirements engineering method was used, resulting in a goal-tree in which requirements are structured. This structure shows requirements related to the input of the instrument; stating

  4. Review of Special Standards in Quality Management Systems Audits in Automotive Production

    Science.gov (United States)

    Šurinová, Yulia

    2013-12-01

    Quality management systems (QMS) in automotive industry generally have several differences in comparison with other industrial branches. Different customers have their own specific requirements, including requirements for quality audits. Audits are one of the coretools of quality management to make the PDCA (Plan - Do - Check - Act) cycle work. As a matter of fact, compliance with ISO/TS 16949:2009 requirements is a condition for supplying the automotive industry. However, there are some standards which co-exist together with the ISO 9001 based management systems and technical specification for QMS in automotive ISO/TS16949. Which are those specific standards in automotive industry and what standard to use and why - those are the questions to be answered in this paper. The aim of the paper is to review what standards are used for audits implementation in automotive industry in the Slovak Republic, and why the organizations keep following those "extra" standards even if certification for ISO/TS 16949 is required by all the car makers. The paper is structured as follows: after short introduction to the topic and related terms, presented is our methodology. . In the third section, the achieved results are discussed. And finally, the principal findings of the paper, limitations and conclusions are presented.

  5. SafeCare: An Innovative Approach for Improving Quality Through Standards, Benchmarking, and Improvement in Low- and Middle- Income Countries.

    Science.gov (United States)

    Johnson, Michael C; Schellekens, Onno; Stewart, Jacqui; van Ostenberg, Paul; de Wit, Tobias Rinke; Spieker, Nicole

    2016-08-01

    In low- and middle-income countries (LMICs), patients often have limited access to high-quality care because of a shortage of facilities and human resources, inefficiency of resource allocation, and limited health insurance. SafeCare was developed to provide innovative health care standards; surveyor training; a grading system for quality of care; a quality improvement process that is broken down into achievable, measurable steps to facilitate incremental improvement; and a private sector-supported health financing model. Three organizations-PharmAccess Foundation, Joint Commission International, and the Council for Health Service Accreditation of Southern Africa-launched SafeCare in 2011 as a formal partnership. Five SafeCare levels of improvement are allocated on the basis of an algorithm that incorporates both the overall score and weighted criteria, so that certain high-risk criteria need to be in place before a facility can move to the next SafeCare certification level. A customized quality improvement plan based on the SafeCare assessment results lists the specific, measurable activities that should be undertaken to address gaps in quality found during the initial assessment and to meet the nextlevel SafeCare certificate. The standards have been implemented in more than 800 primary and secondary facilities by qualified local surveyors, in partnership with various local public and private partner organizations, in six sub-Saharan African countries (Ghana, Kenya, Nigeria, Namibia, Tanzania, and Zambia). Expanding access to care and improving health care quality in LMICs will require a coordinated effort between institutions and other stakeholders. SafeCare's standards and assessment methodology can help build trust between stakeholders and lay the foundation for country-led quality monitoring systems.

  6. Variegated operation of MAPS reactors after enmasse' coolant channel replacement: a tale-tell signature of high standard fuel bundle production quality

    International Nuclear Information System (INIS)

    Jena, J.K.; Sahu, J.K.; Arularasan, V.; Sivagurnathan, D.; Rathakrishnan, S.; Ramamurthy, K.

    2009-01-01

    After the Enmasse' Coolant Channel Replacement (EMCCR) of both the reactors of Madras Atomic Power Station (MAPS), they have put up a good performance, as far as core integrity is considered. This is a tale-tell signature of the high quality of the fuel bundles manufactured by Nuclear Fuel Complex (NFC), Hyderabad. Both the reactor cores have been loaded with various types of fuel bundles viz. Natural Uranium (NU), Depleted Uranium (DU), and Deeply Depleted Uranium (DDU) and were operated at different power level with different flux configuration at different stages of operation. Even around 1026 low burn up bundle (<2500 MWD/TeU) were transferred from MAPS-1 to MAPS-2, first time in the history of PHWRS. During all such variegated operations, the Primary Heat Transport (PHT) system 131 I activity, which is synonymous with the core integrity, was maintaining low for most of the reactor operation period. However, recently a low burn up fuel bundle failure has been observed in MAPS-1. Even though the overall failure rate is very low, the cause of such failure needs to be ascertained for taking appropriate action to maintain the high standards of quality in the manufacturing process of the fuel bundles. (author)

  7. The importance of standardized observations to evaluate nutritional care quality in the survey process.

    Science.gov (United States)

    Schnelle, John F; Bertrand, Rosanna; Hurd, Donna; White, Alan; Squires, David; Feuerberg, Marvin; Hickey, Kelly; Simmons, Sandra F

    2009-10-01

    Guidelines written for government surveyors who assess nursing home (NH) compliance with federal standards contain instructions to observe the quality of mealtime assistance. However, these instructions are vague and no protocol is provided for surveyors to record observational data. This study compared government survey staff observations of mealtime assistance quality to observations by research staff using a standardized protocol that met basic standards for accurate behavioral measurement. Survey staff used either the observation instructions in the standard survey process or those written for the revised Quality Improvement Survey (QIS). Trained research staff observed mealtime care in 20 NHs in 5 states during the same time period that survey staff evaluated care in the same facilities, although it could not be determined if survey and research staff observed the same residents during the same meals. Ten NHs were evaluated by government surveyors using the QIS survey instructions and 10 NHs were evaluated by surveyors using the standard survey instructions. Research staff observations using a standardized observation protocol identified a higher proportion of residents receiving inadequate feeding assistance during meals relative to survey staff using either the standard or QIS survey instructions. For example, more than 50% of the residents who ate less than half of their meals based on research staff observation were not offered an alternative to the served meal, and the lack of alternatives, or meal substitutions, was common in all 20 NHs. In comparison, the QIS survey teams documented only 2 instances when meal substitutes were not offered in 10 NHs and the standard survey teams documented no instances in 10 NHs. Standardized mealtime observations by research staff revealed feeding assistance care quality issues in all 20 study NHs. Surveyors following the instructions in either the standard or revised QIS surveys did not detect most of these care quality

  8. A strategy to develop and implement Canadian standards for quality assurance in radiation therapy

    International Nuclear Information System (INIS)

    1999-05-01

    In Canada, the Atomic Energy Control Board (AECB) regulates the limits of radiation exposure to the public and to workers in industry. In 1993, it discussed the fact that the safety of radiation therapy patients who receive medical exposures is not regulated [AE93]. The Group of Medical Advisors (GMA) to the AECB initiated a research contract to review quality assurance in Canadian radiation oncology centres and nuclear medicine departments. The review [MA95] revealed that the level of quality assurance in radiation therapy facilities varied across the country. As a result, the GMA undertook its own review of quality assurance in radiation therapy centres and made recommendations on how to achieve a uniform national system [MA98]. In response to the GMA report, the President of the AECB formed a Joint Working Group (JWG-11) to propose how Canadian Standards for Quality Assurance in Radiation Therapy could be developed and implemented. These national standards for quality assurance will serve as a common basis for establishing and evaluating quality assurance programs at individual radiation therapy centres. These standards should address the structure of quality assurance programs and quality assurance for radiation therapy equipment, personnel, and procedures. (author)

  9. Implementation of ISO 9000 Quality Standard into Adult Education

    Directory of Open Access Journals (Sweden)

    Andrej Sotošek

    2000-12-01

    Full Text Available Competition in the field of adult education in Slovenia has become very tough  in the second half of the 1990s. Therefore, educational institutions are forced to use every advantage over the competitors in the educational market. One of them is the quality system in educational process. Such competitive position setting strategic development objectives is also the strategy of UPI - Ljudska univerza Žalec. Through development objectives, relationships with our partners and customers, as well as on the basis of analysis of the position and connections of Slovenia within the European Union and its involvement in international projects we estimated that we should set up a quality system in our institution involving managerial, organisational and professional function. It is important that the system should be comparable and verifiable according to the European standards. We have chosen the Quality System according to ISO 9000 quality standards as the most suitable model. It offers an institutional framework as well as a good basis for an internal and external verification of the efficiency of the system in real life. It also enables corrections to deviations. However, it lacks a stronger stress on internal self-control and self-evaluation, which is emphasised in the model of quality assurance in education developed by a group of experts to order of Ministry of Education and Sport. Both model s can be combined and are mutually compatible. I am convinced of the great importance of self-evaluation in education. Yet, without an appropriate institutional framework and basic external verification the self-evaluation remains on the interna! and subjective level of judgement within an individual educational institution.

  10. Producing high-quality negatives from ERTS black-and-white transparancies

    Science.gov (United States)

    Richard J. Myhre

    1973-01-01

    A method has been devised for producing high-quality black-and-white negatives quickly and efficiently from dense transparencies orgininating from Earth Resources Technology Satellite imagery. Transparencies are evaluated on a standard light source to determine exposure and processing information needed for making negatives. A “System ASA Rating” was developed by...

  11. Rapid COJEC versus standard induction therapies for high-risk neuroblastoma.

    Science.gov (United States)

    Peinemann, Frank; Tushabe, Doreen A; van Dalen, Elvira C; Berthold, Frank

    2015-05-19

    Neuroblastoma is a rare malignant disease and mainly affects infants and very young children. The tumors mainly develop in the adrenal medullary tissue and an abdominal mass is the most common presentation. The high-risk group is characterized by metastasis and other characteristics that increase the risk for an adverse outcome. In the rapid COJEC induction schedule, higher single doses of selected drugs than standard induction schedules are administered over a substantially shorter treatment period, with shorter intervals between cycles. Shorter intervals and higher doses increase the dose intensity of chemotherapy and might improve survival. The aim of this study was to evaluate the efficacy and adverse events of the rapid COJEC induction schedule as compared to standard induction schedules in patients with high-risk neuroblastoma (as defined by the International Neuroblastoma Risk Group (INRG) classification system). Outcomes of interest were complete response, early toxicity and treatment-related mortality as primary endpoints and overall survival, progression- and event-free survival, late non-hematological toxicity, and health-related quality of life as secondary endpoints. We searched the electronic databases CENTRAL (2014, Issue 11), MEDLINE (PubMed), and EMBASE (Ovid) for articles from inception to 11 November 2014. Further searches included trial registries, conference proceedings, and reference lists of recent reviews and relevant articles. We did not apply limits on publication year or languages. Randomized controlled trials evaluating the rapid COJEC induction schedule for high-risk neuroblastoma patients compared to standard induction schedules. Two review authors performed study selection, abstracted data on study and patient characteristics, and assessed risk of bias independently. We resolved differences by discussion or by appeal to a third review author. We performed analyses according to the guidelines of the Cochrane Handbook for Systematic

  12. Standardization of Image Quality Analysis – ISO 19264

    DEFF Research Database (Denmark)

    Wüller, Dietmar; Kejser, Ulla Bøgvad

    2016-01-01

    There are a variety of image quality analysis tools available for the archiving world, which are based on different test charts and analysis algorithms. ISO has formed a working group in 2012 to harmonize these approaches and create a standard way of analyzing the image quality for archiving...... systems. This has resulted in three documents that have been or are going to be published soon. ISO 19262 defines the terms used in the area of image capture to unify the language. ISO 19263 describes the workflow issues and provides detailed information on how the measurements are done. Last...... but not least ISO 19264 describes the measurements in detail and provides aims and tolerance levels for the different aspects. This paper will present the new ISO 19264 technical specification to analyze image quality based on a single capture of a multi-pattern test chart, and discuss the reasoning behind its...

  13. The negotiation of quality standards: A social interactionists approach to fruit and vegetable distribution in Argentina

    NARCIS (Netherlands)

    Arce, A.M.G.; Viteri, M.L.

    2013-01-01

    This article addresses food quality standards. It suggests that writing on standards creates a flat view of the subject, failing to grasp the richness of the multiple self-organizing practices that shape quality within functioning markets. The article documents the social dimension of quality and

  14. Using Early Learning Standards to Provide High-Quality Education for All Children: The Early Learning Guidelines Toolkit

    Science.gov (United States)

    Flores, Roseanne L.; Curby, Timothy W.; Coleman, Hardin; Melo, Kristan

    2016-01-01

    Today with the rise in the number of 3- to 6-year-old children enrolled in center-based early childhood programs, and a focus on program quality, it becomes imperative for educators to have a better understanding of the role research plays in establishing high-quality programs as these programs provide much of the foundation that supports early…

  15. ISO 9000 and quality standards improvement in the maintenance ...

    African Journals Online (AJOL)

    This study investigated ISO 9000 as a tool for improving quality standards in ... The study used cross-sectional descriptive research design, using quantitative research ... enhance business performance and competiveness of manufacturing firms. ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  16. A holistic strategy for quality and safety control of traditional Chinese medicines by the "iVarious" standard system.

    Science.gov (United States)

    Chen, Anzhen; Sun, Lei; Yuan, Hang; Wu, Aiying; Lu, Jingguang; Ma, Shuangcheng

    2017-10-01

    An effective quality control system is the key to ensuring the quality, safety and efficacy of traditional Chinese medicines (TCMs). However, the current quality standard research lacks the top-design and systematic design, mostly based on specific technologies or evaluation methods. To resolve the challenges and questions of quality control of TCMs, a brand-new quality standard system, named "iVarious", was proposed. The system comprises eight elements in a modular format. Meaning of every element was specifically illustrated via corresponding research instances. Furthermore, frankincense study was taken as an example for demonstrating standards and research process, based on the "iVarious" system. This system highlighted a holistic strategy for effectiveness, security, integrity and systematization of quality and safety control standards of TCMs. The establishment of "iVarious" integrates multi-disciplinary technologies and progressive methods, basis elements and key points of standard construction. The system provides a novel idea and technological demonstration for regulation establishment of TCMs quality standards.

  17. Quality Service Standard of Food and Beverage Service Staff in Hotel

    OpenAIRE

    Thanasit Suksutdhi

    2014-01-01

    This survey research aims to study the standard of service quality of food and beverage service staffs in hotel business by studying the service standard of three sample hotels, Siam Kempinski Hotel Bangkok, Four Seasons Resort Chiang Mai, and Banyan Tree Phuket. In order to find the international service standard of food and beverage service, triangular research, i.e. quantitative, qualitative, and survey were employed. In this research, questionnaires and in-depth interview were used for ge...

  18. IEEE [Institute of Electrical and Electronics Engineers] standards and nuclear software quality engineering

    International Nuclear Information System (INIS)

    Daughtrey, T.

    1988-01-01

    Significant new nuclear-specific software standards have recently been adopted under the sponsorship of the American Nuclear Society and the American Society of Mechanical Engineers. The interest of the US Nuclear Regulatory Commission has also been expressed through their issuance of NUREG/CR-4640. These efforts all indicate a growing awareness of the need for thorough, referenceable expressions of the way to build in and evaluate quality in nuclear software. A broader professional perspective can be seen in the growing number of software engineering standards sponsored by the Institute of Electrical and Electronics Engineers (IEEE) Computer Society. This family of standards represents a systematic effort to capture professional consensus on quality practices throughout the software development life cycle. The only omission-the implementation phase-is treated by accepted American National Standards Institute or de facto standards for programming languages

  19. Standard guide for establishing a quality assurance program for uranium conversion facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide provides guidance and recommended practices for establishing a comprehensive quality assurance program for uranium conversion facilities. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate health and safety practices and determine the applicability of regulatory limitations prior to use. 1.3 The basic elements of a quality assurance program appear in the following order: FUNCTION SECTION Organization 5 Quality Assurance Program 6 Design Control 7 Instructions, Procedures & Drawings 8 Document Control 9 Procurement 10 Identification and Traceability 11 Processes 12 Inspection 13 Control of Measuring and Test Equipment 14 Handling, Storage and Shipping 15 Inspection, Test and Operating Status 16 Control of Nonconforming Items 17 Corrective Actions 18 Quality Assurance Records 19 Audits 20 TABLE 1 NQA-1 Basic Requirements Relat...

  20. [Study on seed quality test and quality standard of Pesudostellaria heterophylla].

    Science.gov (United States)

    Xiao, Cheng-Hong; Zhou, Tao; Jiang, Wei-Ke; Chen, Min; Xiong, Hou-Xi; Liao, Ming-Wu

    2014-08-01

    Referring to the rules for agricultural seed testing (GB /T 3543-1995) issued by China, the test of sampling, seed purity, weight per 1 000 seeds, seed moisture, seed viability and germination rate had been studied for screening seed quality test methods of Pesudostellaria heterophylla. The seed quality from different collection areas was measured. The results showed that at least 6.5 g seeds should be sampled and passed through 10-mesh sieve for purity analysis. The weight of 1 000 seeds was determined by using the 500-seed method. The phenotypic observation and size measurement were used for authenticity testing. The seed moisture was determined under the higher temperature (130 ± 2) degrees C for 5 hours. The seeds were dipped into 0.2% TTC sustaining 1 hour at 40 degrees C, then the viability could be determined. The break dormancy seeds were cultured on sand at 10 degrees C. K cluster analysis was applied for the data analysis, the seed quality from different collection areas grading of P. Heterophylla was described as three grades. The seed quality of each grade should reach following requirements: for first grade seeds, germination rate ≥ 86%, 1 000-grain weight ≥ 2.59 g, purity ≥ 87%, moisture ≤ 13.1%; for second grade seeds, germination rate ≥ 70%, 1 000-grain weight ≥ 2.40 g, purity ≥ 77%, moisture ≤ 14.3%; for third grade seeds, germination rate ≥ 41%, 1 000-grain weight ≥ 2.29 g, purity ≥ 76%, moisture ≤ 15.8%. The seed testing methods for quality items of P. heterophylla had been initially established, as well as the primary P. heterophylla seed quality classification standard.

  1. Russian Higher Education and European Standards of Quality Assurance

    Science.gov (United States)

    Motova, Galina; Pykko, Ritta

    2012-01-01

    This article considers the relevance and implementation of European approaches to quality assurance in the context of the Russian educational system. It covers the issues of transformation of the higher education system during the post-Soviet period, specific features of the state accreditation system, the impact of the European Standards and…

  2. Haugh Unit: Gold Standard of Egg Quality

    Science.gov (United States)

    Rapidly determining shell egg quality in an objective manner is not an easy task. Candling is most often utilized as a quick method for assessing egg quality in a non-destructive manner, but it is a highly subjective method. As you have experienced this week, when candling, it is almost impossibl...

  3. Solution standards for quality control of nuclear-material analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.

    1981-01-01

    Analytical chemistry measurement control depends upon reliable solution standards. At the Savannah River Plant Control Laboratory over a thousand analytical measurements are made daily for process control, product specification, accountability, and nuclear safety. Large quantities of solution standards are required for a measurement quality control program covering the many different analytical chemistry methods. Savannah River Plant produced uranium, plutonium, neptunium, and americium metals or oxides are dissolved to prepare stock solutions for working or Quality Control Standards (QCS). Because extensive analytical effort is required to characterize or confirm these solutions, they are prepared in large quantities. These stock solutions are diluted and blended with different chemicals and/or each other to synthesize QCS that match the matrices of different process streams. The target uncertainty of a standard's reference value is 10% of the limit of error of the methods used for routine measurements. Standard Reference Materials from NBS are used according to special procedures to calibrate the methods used in measuring the uranium and plutonium standards so traceability can be established. Special precautions are required to minimize the effects of temperature, radiolysis, and evaporation. Standard reference values are periodically corrected to eliminate systematic errors caused by evaporation or decay products. Measurement control is achieved by requiring analysts to analyze a blind QCS each shift a measurement system is used on plant samples. Computer evaluation determines whether or not a measurement is within the +- 3 sigma control limits. Monthly evaluations of the QCS measurements are made to determine current bias correction factors for accountability measurements and detect significant changes in the bias and precision statistics. The evaluations are also used to plan activities for improving the reliability of the analytical chemistry measurements

  4. Acidic precipitation: considerations for an air-quality standard

    Energy Technology Data Exchange (ETDEWEB)

    Evans, L.S.; Hendrey, G.R.; Stensland, G.J.; Johnson, D.W.; Francis, A.J.

    1980-01-01

    Acidic precipitation, wet or frozen deposition with a hydrogen ion concentration greatern than 2.5 ..mu..eq l/sup -1/ is a significant air pollution problem in the United States. The chief anions accounting for the hydrogen ions in rainfall are nitrate and sulfate. Agricultural systems are more likely to derive net nutritional benefits from increasing inputs of acidic rain than are forest systems when soils alone are considered. Agricultural soils may benefit because of the high N and S requirements of agricultural plants. Detrimental effects to forest soils may result if atmospheric H/sup +/ inputs significantly add to or exceed H/sup +/ production by soils. Acidification of fresh waters of southern Scandinavia, southwestern Scotland, southeastern Canada, and northeastern United States is caused by acid deposition. Areas of these regions in which this acidification occurs have in common, highly acidic precipitation with volume weighted mean annual H/sup +/ concentrations of 25 ..mu..eq l/sup -1/ or higher and slow weathering granitic or precambrian bedrock with thin soils deficient in minerals which would provide buffer capacity. Biological effects of acidification of fresh waters are detectable below pH 6.0. As lake and stream pH levels decrease below pH. 6.0, many species of plants, invertebrates, and vertebrates are progressively eliminated. Generally, fisheries are impacted below pH 5.0 and are completely destroyed below pH 4.8. There are few studies that document effects of acidic precipitation on terrestrial vegetation to establish an air quality standard. It must be demonstrated that current levels of precipitation acidity alone significantly injure terrestrial vegetation. In terms of documented damanges, current research indicates that establishing a standard for precipitation for the volume weighted annual H/sup +/ concentration at 25 ..mu..eq l/sup -1/ may protect the most sensitive areas from permanent lake acidification.

  5. Model for selecting quality standards for a salad bar through identifying elements of customer satisfaction.

    Science.gov (United States)

    Ouellet, D; Norback, J P

    1993-11-01

    Continuous quality improvement is the new requirement of the Joint Commission on Accreditation of Healthcare Organizations. This means that meeting quality standards will not be enough. Dietitians will need to improve those standards and the way they are selected. Because quality is defined in terms of the customers, all quality improvement projects must start by defining what customers want. Using a salad bar as an example, this article presents and illustrates a technique developed in Japan to identify which elements in a product or service will satisfy or dissatisfy consumers. Using a model and a questionnaire format developed by Kano and coworkers, 273 students were surveyed to classify six quality elements of a salad bar. Four elements showed a dominant "must-be" characteristic: food freshness, labeling of the dressings, no spills in the food, and no spills on the salad bar. The two other elements (food easy to reach and food variety) showed a dominant one-dimensional characteristic. By better understanding consumer perceptions of quality elements, foodservice managers can select quality standards that focus on what really matters to their consumers.

  6. 77 FR 25721 - Small Entity Compliance Guide: Bottled Water: Quality Standard: Establishing an Allowable Level...

    Science.gov (United States)

    2012-05-01

    ...] Small Entity Compliance Guide: Bottled Water: Quality Standard: Establishing an Allowable Level for di(2... ``Bottled Water: Quality Standard: Establishing an Allowable Level for di(2- ethylhexyl)phthalate--Small... an allowable level for di(2- ethylhexyl)phthalate (DEHP). This final rule is effective April 16, 2012...

  7. Implementation and translation: from European standards and guidelines for quality assurance to education quality work in higher education institutions

    NARCIS (Netherlands)

    Westerheijden, Donald F.; Kohoutek, Jan; Eggins, Heather

    2014-01-01

    The Standards and Guidelines for Quality Assurance in the European Higher Education Area (ESG for short) have been part of the regulative infrastructure of the European Higher Education Area (EHEA) since 2005 (European Association for Quality Assurance in Higher Education, 2009).

  8. Correlation pattern recognition: optimal parameters for quality standards control of chocolate marshmallow candy

    Science.gov (United States)

    Flores, Jorge L.; García-Torales, G.; Ponce Ávila, Cristina

    2006-08-01

    This paper describes an in situ image recognition system designed to inspect the quality standards of the chocolate pops during their production. The essence of the recognition system is the localization of the events (i.e., defects) in the input images that affect the quality standards of pops. To this end, processing modules, based on correlation filter, and segmentation of images are employed with the objective of measuring the quality standards. Therefore, we designed the correlation filter and defined a set of features from the correlation plane. The desired values for these parameters are obtained by exploiting information about objects to be rejected in order to find the optimal discrimination capability of the system. Regarding this set of features, the pop can be correctly classified. The efficacy of the system has been tested thoroughly under laboratory conditions using at least 50 images, containing 3 different types of possible defects.

  9. Establishment of standard x-ray qualities to be used in diagnostic level at SSDLs

    International Nuclear Information System (INIS)

    A-Aziz, R.O.

    2007-08-01

    The objective of the present work is to modify x-ray machine (used by the secondary standard dosimetry laboratory in Sudan) to produce x-ray qualities suitable for the calibration at diagnostic level. It based on experimental evaluations. The importance of this study appears in development of protocols to calibrate the instruments used in diagnostic radiology in by good response of the instruments and low cost. In particular, the half value layer (HVL) values for the following qualities 40, 60, 80, 100, 120 and 150 were determined using various attenuation layers. Ionization chamber was used to determine the free air kerma rate at a distance of 100 cm from the x-ray generator. The obtained HVL values were compared with standard values of diagnostic levels. It was observed that the HVL of the present x-ray machine in most qualities are smaller than the standard ones. An approved method (described in the standard IEC 61267) was applied to determine the amount of additional filtration required to meet the standard values. The results show that the available cupper layers were not suitable for this purpose as most of the x-ray was absorbed in the material. Aluminum layers, on the other hand , show good performances to reduce the beams to the desired levels. The amount of additional filtration (from aluminum layers) needed in order to establish standard x-ray qualities to be used in diagnostic level were determined.(Author)

  10. From 'Compliance-based' to 'Performance-based' Quality - A trend in and evolution of U. S. quality standards

    International Nuclear Information System (INIS)

    Brown, Douglas A.; Taylor, H. Stephen; Johnson, Robert B.; Erler, Bryan A.; Daley, Thomas J.

    1995-01-01

    This paper traces the evolution of quality systems for nuclear power plant design, procurement, fabrication, installation, pre-operational testing, operations and maintenance in the U. S., as reflected in consensus standards such as N45.2, NQA-1, etc. Using a 'Defense-In-Depth' Quality Model, it highlights the changes in understanding where the responsibilities for quality should reside. Industries' growing recognition and operating experience show that a 'graded' approach to quality, based on safety significance, can be used to determine which quality criteria apply and the depth of implementing those criteria, resulting in potential long term cost savings and increased effectiveness) is also examined and discussed. Together, these two approaches form the basis for a performance-based quality system suitable for the business and technical environment of the 1990's and beyond. Performance-based Quality System - an approach that focuses on the end results, not the process, that directly contribute to safe and reliable plant operations. This approach includes monitoring performance or condition against predetermined, licensee-established goals, limits, or criteria in a manner sufficient to provide reasonable assurance that the safety function will be fulfilled. These criteria are based upon the design basis safety function, operating experience, and pertinent reliability studies. A licensee is allowed the flexibility to determine how best to achieve the results and adjust the application of quality elements accordingly. The roles of the individual worker, site/line supervision and management, independent quality verifiers (QA and QC), and external regulators are examined in the context of where and how industry quality standards have historically placed emphasis and accountability. The changes in these standards and their of effects are illustrated. Based on industry experience, the current understanding of the controls necessary to achieve safe, reliable and

  11. Routine chest and abdominal high-pitch CT: An alternative low dose protocol with preserved image quality

    International Nuclear Information System (INIS)

    Amacker, Nadja A.; Mader, Caecilia; Alkadhi, Hatem; Leschka, Sebastian; Frauenfelder, Thomas

    2012-01-01

    Objective: To investigate the radiation dose and image quality of the high-pitch dual source computer tomography (DSCT) for routine chest and abdominal scans. Methods: 130 consecutive patients (62 female, 68 male, median age 55 years) were included. All patients underwent 128-slice high-pitch DSCT (chest n = 99; abdomen n = 84) at a pitch of 3.2. Two observers independently rated image quality using a 4-point score (1: excellent to 4: non-diagnostic). Image noise was measured and operational radiation dose quantities were recorded. An additional group of 132 patients (chest, n = 80; abdomen n = 52) scanned with standard-pitch CT matched for age, gender, and body mass index (BMI) served as control group. Results: Interobserver agreement for image quality rating was good (k = 0.74). Subjective image quality of high-pitch CT was diagnostic in all patients (median score chest; 2, median score abdomen: 2). Image noise of high-pitch CT was comparable to standard-pitch for the chest (p = 0.32) but increased in the abdomen (p < 0.0001). For high-pitch CT radiation dose was 4.4 ± 0.9 mSv (chest) and 6.5 ± 1.2 mSv (abdomen). These values were significantly lower compared to standard-pitch CT (chest: 5.5 ± 1.2 mSv; abdomen: 11.3 ± 3.8 mSv). Conclusion: Based on the technical background high-pitch dual source CT may serve as an alternative scan mode for low radiation dose routine chest and abdominal CT.

  12. International Financial Reporting Standards Convergence and Quality of Accounting Information: Evidence from Indonesia

    OpenAIRE

    Yusrina, Hasyyati; Mukhtaruddin, Mukhtaruddin; Fuadah, Luk Luk; Sulong, Zunaidah

    2017-01-01

    The International Financial Reporting Standards (IFRS) initiated by International Accounting Standard Board (IASB) are principle-based standard that require extensive disclosure of financial statements and accounting information as compared to prior standard that is the Generally Accepted Accounting Principles (GAAP) to better reflect the overall quality of company’s performance. Therefore, the IFRS convergence is expected to improve the reliability of financial reporting by limiting opportun...

  13. Isolation of high quality RNA from pistachio (Pistacia vera L.) and other woody plants high in secondary metabolites.

    Science.gov (United States)

    Moazzam Jazi, Maryam; Rajaei, Saideh; Seyedi, Seyed Mahdi

    2015-10-01

    The quality and quantity of RNA are critical for successful downstream transcriptome-based studies such as microarrays and RNA sequencing (RNA-Seq). RNA isolation from woody plants, such as Pistacia vera, with very high amounts of polyphenols and polysaccharides is an enormous challenge. Here, we describe a highly efficient protocol that overcomes the limitations posed by poor quality and low yield of isolated RNA from pistachio and various recalcitrant woody plants. The key factors that resulted in a yield of 150 μg of high quality RNA per 200 mg of plant tissue include the elimination of phenol from the extraction buffer, raising the concentration of β-mercaptoethanol, long time incubation at 65 °C, and nucleic acid precipitation with optimized volume of NaCl and isopropyl alcohol. Also, the A260/A280 and A260/A230 of extracted RNA were about 1.9-2.1and 2.2-2.3, respectively, revealing the high purity. Since the isolated RNA passed highly stringent quality control standards for sensitive reactions, including RNA sequencing and real-time PCR, it can be considered as a reliable and cost-effective method for RNA extraction from woody plants.

  14. Environmental Monitoring, Water Quality - MO 2009 Water Quality Standards - Table G Lake Classifications and Use Designations (SHP)

    Data.gov (United States)

    NSGIC State | GIS Inventory — This data set contains Missouri Water Quality Standards (WQS) lake classifications and use designations described in the Missouri Code of State Regulations (CSR), 10...

  15. Highly purified water production technology. The influence of water purity on steam quality

    International Nuclear Information System (INIS)

    Ganter, J.

    1975-01-01

    The fundamental question related to high-pressure steam generation, intended for powering steam turbines, concerns steam production conditions based on constant quality standards. The characteristics of water (salinity, silica concentration) are indicated for a given steam quality as a function of the pressure. Two processes for the purification of feedwater for high pressure boilers are described: a treatment using precoated cellulose or resin filters and a treatment using mixed-bed ion exchangers. When ultrapure water is required, the demineralized water is filtred using microfiltration and ultrafiltration processes [fr

  16. China's High-technology Standards Development

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    There are several major technology standards, including audio video coding (AVS), automotive electronics, third generation (3G) mobile phones, mobile television, wireless networks and digital terrestrial television broadcasting, that have been released or are currently under development in China. This article offers a detailed analysis of each standard and studies their impact on China's high-technology industry.

  17. A holistic strategy for quality and safety control of traditional Chinese medicines by the “iVarious” standard system

    Directory of Open Access Journals (Sweden)

    Anzhen Chen

    2017-10-01

    Full Text Available An effective quality control system is the key to ensuring the quality, safety and efficacy of traditional Chinese medicines (TCMs. However, the current quality standard research lacks the top-design and systematic design, mostly based on specific technologies or evaluation methods. To resolve the challenges and questions of quality control of TCMs, a brand-new quality standard system, named “iVarious”, was proposed. The system comprises eight elements in a modular format. Meaning of every element was specifically illustrated via corresponding research instances. Furthermore, frankincense study was taken as an example for demonstrating standards and research process, based on the “iVarious” system. This system highlighted a holistic strategy for effectiveness, security, integrity and systematization of quality and safety control standards of TCMs. The establishment of “iVarious” integrates multi-disciplinary technologies and progressive methods, basis elements and key points of standard construction. The system provides a novel idea and technological demonstration for regulation establishment of TCMs quality standards.

  18. Establishment of quality assessment standard for mammographic equipment: evaluation of phantom and clinical images

    International Nuclear Information System (INIS)

    Lee, Sung Hoon; Choe, Yeon Hyeon; Chung, Soo Young

    2005-01-01

    The purpose of this study was to establish a quality standard for mammographic equipment Korea and to eventually improve mammographic quality in clinics and hospitals throughout Korea by educating technicians and clinic personnel. For the phantom test and on site assessment, we visited 37 sites and examined 43 sets of mammographic equipment. Items that were examined include phantom test, radiation dose measurement, developer assessment, etc. The phantom images were assessed visually and by optical density measurements. For the clinical image assessment, clinical images from 371 sites were examined following the new Korean standard for clinical image evaluation. The items examined include labeling, positioning, contrast, exposure, artifacts, collimation among others. Quality standard of mammographic equipment was satisfied in all equipment on site visits. Average mean glandular dose was 114.9 mRad. All phantom image test scores were over 10 points (average, 10.8 points). However, optical density measurements were below 1.2 in 9 sets of equipment (20.9%). Clinical image evaluation revealed appropriate image quality in 83.5%, while images from non-radiologist clinics were adequate in 74.6% (91/122), which was the lowest score of any group. Images were satisfactory in 59.0% (219/371) based on evaluation by specialists following the new Korean standard for clinical image evaluation. Satisfactory images had a mean score of 81.7 (1 S.D. =8.9) and unsatisfactory images had a mean score of 61.9 (1 S.D = 11). The correlation coefficient between the two observers was 0.93 (ρ < 0.01) in 49 consecutive cases. The results of the phantom tests suggest that optical density measurements should be performed as part of a new quality standard for mammographic equipment. The new clinical evaluation criteria that was used in this study can be implemented with some modifications for future mammography quality control by the Korean government

  19. 77 FR 74985 - Water Quality Standards for the State of Florida's Streams and Downstream Protection Values for...

    Science.gov (United States)

    2012-12-18

    ... Water Quality Standards for the State of Florida's Streams and Downstream Protection Values for Lakes... its numeric water quality standards for nutrients in Florida that were promulgated and published on.... Water Quality Criteria D. EPA Determination Regarding Florida and EPA's Rulemaking E. EPA Promulgation...

  20. Technical quality assessment of breast ultrasound according to American College of Radiology (ACR) Standards

    International Nuclear Information System (INIS)

    Ko, Kyung Hee; Kim, Eun Kyung; Kim, Young Ah; Son, Eun Ju; Oh, Ki Keun; Chung, Sun Yang

    2003-01-01

    To evaluate the technical quality of breast ultrasound based on American College of Radiology(ACR) standards. Between March 2002 and July 2002, ninety three breast sonograms obtained from 73 institutions were evaluated based on ACR standards for the hardware, technical settings, labeling of the images and identification. Of 93 breast sonograms, a satisfactory compliance with all ACR standards in the performance of breast US examinations was documented in 31% while the remaining 69% did not fully meet all ACR standards. 4.3% of breast US examinations were performed with a convex transducers, and the focal zone was inappropriately positioned in 14.2%. Gray-scale gain was subjectively characterized as inappropriate in 26.9%, and the size of lesion was not measured in 7.5%. Anatomic location of lesions was inappropriately described in 9.3%. The orientation of an US transducer was not properly labeled on any images in 33.3%. Inadequate recording of patient's information was noted in 43.3%. 50% of sonograms at University medical centers and larger general hospitals fully met all ACR standards while 36.8% at radiologic clinics and 12.1% at other private clinics met all ACR standards. Overall, 69% of breast sonograms failed to meet the quality criteria of the ACR standards. Therefore, it is essential to educate the basic technical details in performing breast US for the quality control.

  1. The Harvard Automated Processing Pipeline for Electroencephalography (HAPPE): Standardized Processing Software for Developmental and High-Artifact Data.

    Science.gov (United States)

    Gabard-Durnam, Laurel J; Mendez Leal, Adriana S; Wilkinson, Carol L; Levin, April R

    2018-01-01

    Electroenchephalography (EEG) recordings collected with developmental populations present particular challenges from a data processing perspective. These EEGs have a high degree of artifact contamination and often short recording lengths. As both sample sizes and EEG channel densities increase, traditional processing approaches like manual data rejection are becoming unsustainable. Moreover, such subjective approaches preclude standardized metrics of data quality, despite the heightened importance of such measures for EEGs with high rates of initial artifact contamination. There is presently a paucity of automated resources for processing these EEG data and no consistent reporting of data quality measures. To address these challenges, we propose the Harvard Automated Processing Pipeline for EEG (HAPPE) as a standardized, automated pipeline compatible with EEG recordings of variable lengths and artifact contamination levels, including high-artifact and short EEG recordings from young children or those with neurodevelopmental disorders. HAPPE processes event-related and resting-state EEG data from raw files through a series of filtering, artifact rejection, and re-referencing steps to processed EEG suitable for time-frequency-domain analyses. HAPPE also includes a post-processing report of data quality metrics to facilitate the evaluation and reporting of data quality in a standardized manner. Here, we describe each processing step in HAPPE, perform an example analysis with EEG files we have made freely available, and show that HAPPE outperforms seven alternative, widely-used processing approaches. HAPPE removes more artifact than all alternative approaches while simultaneously preserving greater or equivalent amounts of EEG signal in almost all instances. We also provide distributions of HAPPE's data quality metrics in an 867 file dataset as a reference distribution and in support of HAPPE's performance across EEG data with variable artifact contamination and

  2. The Harvard Automated Processing Pipeline for Electroencephalography (HAPPE: Standardized Processing Software for Developmental and High-Artifact Data

    Directory of Open Access Journals (Sweden)

    Laurel J. Gabard-Durnam

    2018-02-01

    Full Text Available Electroenchephalography (EEG recordings collected with developmental populations present particular challenges from a data processing perspective. These EEGs have a high degree of artifact contamination and often short recording lengths. As both sample sizes and EEG channel densities increase, traditional processing approaches like manual data rejection are becoming unsustainable. Moreover, such subjective approaches preclude standardized metrics of data quality, despite the heightened importance of such measures for EEGs with high rates of initial artifact contamination. There is presently a paucity of automated resources for processing these EEG data and no consistent reporting of data quality measures. To address these challenges, we propose the Harvard Automated Processing Pipeline for EEG (HAPPE as a standardized, automated pipeline compatible with EEG recordings of variable lengths and artifact contamination levels, including high-artifact and short EEG recordings from young children or those with neurodevelopmental disorders. HAPPE processes event-related and resting-state EEG data from raw files through a series of filtering, artifact rejection, and re-referencing steps to processed EEG suitable for time-frequency-domain analyses. HAPPE also includes a post-processing report of data quality metrics to facilitate the evaluation and reporting of data quality in a standardized manner. Here, we describe each processing step in HAPPE, perform an example analysis with EEG files we have made freely available, and show that HAPPE outperforms seven alternative, widely-used processing approaches. HAPPE removes more artifact than all alternative approaches while simultaneously preserving greater or equivalent amounts of EEG signal in almost all instances. We also provide distributions of HAPPE's data quality metrics in an 867 file dataset as a reference distribution and in support of HAPPE's performance across EEG data with variable artifact

  3. Measuring the Software Product Quality during the Software Development Life-Cycle: An ISO Standards Perspective

    OpenAIRE

    Rafa E. Al-Qutaish

    2009-01-01

    Problem statement: The International Organization for Standardization (ISO) published a set of international standards related to the software engineering, such as ISO 12207 and ISO 9126. However, there is a set of cross-references between the two standards. Approach: The ISO 9126 on software product quality and ISO 12207 on software life cycle processes had been analyzed to invistigate the relationships between them and to make a mapping from the ISO 9126 quality characteristics to the ISO 1...

  4. 75 FR 45579 - Water Quality Standards for the State of Florida's Lakes and Flowing Waters; Supplemental Notice...

    Science.gov (United States)

    2010-08-03

    ... Water Quality Standards for the State of Florida's Lakes and Flowing Waters; Supplemental Notice of Data...), proposing numeric nutrient water quality criteria to protect aquatic life in lakes and flowing waters within... will consider the comments received before finalizing the proposed rule, ``Water Quality Standards for...

  5. The hazardous priority substances in Italy: National rules and environmental quality standard in marine environment

    International Nuclear Information System (INIS)

    Maggi, Chiara; Onorati, Fulvio; Lamberti, Claudia Virno; Cicero, Anna Maria

    2008-01-01

    Article number 16 of the Water Framework Directive (Directive 2000/60/EC) lays down the community strategy for establishment of harmonised quality standards for the priority substances and other substances posing a significant risk to the aquatic environment. In order to achieve the protection objectives of the Directive 2000/60/EC, the Italian Ministry of the Environment proposed the quality standards for surface water, sediments and biota related to the priority substances listed in the decision No. 2455/2001/EC of the European Parliament and of the Council of November 20 (2001) [Decision N. 2455/2001/EC of the European Parliament and of the Council of 20 November 2001. The list of priority substances in the field of water policy and amending Directive 2000/60/EC. Official Journal of the European Communities, 15.12.2001, p. 5]. Particularly, for the protection of the marine environment, the proposed Italian rules state that, from 1 January 2021, the concentrations of the hazardous priority substances in Italian marine and lagoon waters must be near the natural background for natural substances, like metals, and near zero for the anthropogenic one. According to Directive 2000/60/EC, the Italian Ministry of Environment issued in 2003 Decree 367 in which has derived 160 Environmental Quality Standard (EQS) for water and 27 Environmental Quality Objective (EQO) for sediment of marine coastal area, lagoons and coastal ponds. Biota quality standards have still to be fixed. The paper illustrates the criteria applied for the definition of the quality standards and some comments are presented

  6. Harmonization of monographic standards is needed to ensure the quality of Chinese medicinal materials

    Directory of Open Access Journals (Sweden)

    Zhao Sandy

    2009-09-01

    Full Text Available Abstract This article provides an overview on the regulations of Chinese medicinal materials (CMMs in various countries and regions. Harmonization of CMM monographs would provide standards for the quality control of CMM products and play an important role in the modernization and globalization of Chinese medicine. A harmonized regulatory system would improve the quality of CMMs thereby ensuring the safety of the products and assisting Chinese medicine practitioners in their practice. The fast growing demand worldwide for traditional medicines calls for harmonized monographic standards to safeguard the safety and quality of CMM products.

  7. [Procedure of seed quality testing and seed grading standard of Prunus humilis].

    Science.gov (United States)

    Wen, Hao; Ren, Guang-Xi; Gao, Ya; Luo, Jun; Liu, Chun-Sheng; Li, Wei-Dong

    2014-11-01

    So far there exists no corresponding quality test procedures and grading standards for the seed of Prunus humilis, which is one of the important source of base of semen pruni. Therefor we set up test procedures that are adapt to characteristics of the P. humilis seed through the study of the test of sampling, seed purity, thousand-grain weight, seed moisture, seed viability and germination percentage. 50 cases of seed specimens of P. humilis tested. The related data were analyzed by cluster analysis. Through this research, the seed quality test procedure was developed, and the seed quality grading standard was formulated. The seed quality of each grade should meet the following requirements: for first grade seeds, germination percentage ≥ 68%, thousand-grain weight 383 g, purity ≥ 93%, seed moisture ≤ 5%; for second grade seeds, germination percentage ≥ 26%, thousand-grain weight ≥ 266 g, purity ≥ 73%, seed moisture ≤9%; for third grade seeds, germination percentage ≥ 10%, purity ≥ 50%, thousand-grain weight ≥ 08 g, seed moisture ≤ 13%.

  8. On criteria for examining analysis quality with standard reference material

    International Nuclear Information System (INIS)

    Yang Huating

    1997-01-01

    The advantages and disadvantages and applicability of some criteria for examining analysis quality with standard reference material are discussed. The combination of the uncertainties of the instrument examined and the reference material should be determined on the basis of specific situations. Without the data of the instrument's uncertainty, it would be applicable to substitute the standard deviation multiplied by certain times for the uncertainty. The result of the examining should not result in more error reported in routine measurements than it really is. Over strict examining should also be avoided

  9. Paediatric rehabilitation treatment standards: a method for quality assurance in Germany

    Directory of Open Access Journals (Sweden)

    Jutta Ahnert

    2014-07-01

    Full Text Available Over the last few years, the German Pension Insurance has implemented a new method of quality assurance for inpatient rehabilitation of children and adolescents diagnosed with bronchial asthma, obesity, or atopic dermatitis: the so-called rehabilitation treatment standards (RTS. They aim at promoting a comprehensive and evidence-based care in rehabilitation. Furthermore, they are intended to make the therapeutic processes in medical rehabilitation as well as potential deficits more transparent. The development of RTS was composed of five phases during which current scientific evidence, expert knowledge, and patient expectations were included. Their core element is the specification of evidence-based treatment modules that describe a good rehabilitation standard for children diagnosed with bronchial asthma, obesity, or atopic dermatitis. Opportunities and limitations of the RTS as a tool for quality assurance are discussed.

  10. X radiation qualities characterization following the standard IEC 61267 recommendations at the calibration laboratory of IPEN

    International Nuclear Information System (INIS)

    Franciscatto, Priscila Cerutti

    2009-01-01

    This work presents a methodology for the X radiation qualities characterization following the new recommendations of the standard 61267 of the International Electrotechnical Commission (IEC) to establish a new procedure for calibration of dosimetric systems used in the field of diagnostic radiology. The reference qualities radiation of IEC 61267: RQR 2 to RQR 10, RQA 2 to RQA 10, RQB 2 to RQB 10 and RQN 2 to RQN 10 were implanted at the calibration laboratory of IPEN (LCI). Their characteristics were analyzed through measurements of beam parameters such as: Practical peak voltage (PPV), specific additional filtrations for each qualities (high purity aluminum of about 99.9%), 1st and 2nd Half Value Layers, homogeneity coefficient. The inherent filtration of the X ray tube was also determined. With the establishment of these radiation qualities, the LCI will be ready to calibrate the measuring instruments of radiation in the new qualities, allowing an improvement in radiological services offered by IPEN. (author)

  11. Cultivating Common Ground: Integrating Standards-Based Visual Arts, Math and Literacy in High-Poverty Urban Classrooms

    Science.gov (United States)

    Cunnington, Marisol; Kantrowitz, Andrea; Harnett, Susanne; Hill-Ries, Aline

    2014-01-01

    The "Framing Student Success: Connecting Rigorous Visual Arts, Math and Literacy Learning" experimental demonstration project was designed to develop and test an instructional program integrating high-quality, standards-based instruction in the visual arts, math, and literacy. Developed and implemented by arts-in-education organization…

  12. Subjective Video Quality Assessment in H.264/AVC Video Coding Standard

    Directory of Open Access Journals (Sweden)

    Z. Miličević

    2012-11-01

    Full Text Available This paper seeks to provide an approach for subjective video quality assessment in the H.264/AVC standard. For this purpose a special software program for the subjective assessment of quality of all the tested video sequences is developed. It was developed in accordance with recommendation ITU-T P.910, since it is suitable for the testing of multimedia applications. The obtained results show that in the proposed selective intra prediction and optimized inter prediction algorithm there is a small difference in picture quality (signal-to-noise ratio between decoded original and modified video sequences.

  13. Standardized measurement of quality of life after incisional hernia repair

    DEFF Research Database (Denmark)

    Jensen, Kristian K; Henriksen, Nadia A; Harling, Henrik

    2014-01-01

    repair. The aim of this systematic review was to analyze existing standardized methods to measure quality of life after incisional hernia repair. DATA SOURCES: A PubMed and Embase search was carried out together with a cross-reference search of eligible papers, giving a total of 26 included studies...

  14. 76 FR 38592 - Phosphorus Water Quality Standards for Florida Everglades

    Science.gov (United States)

    2011-07-01

    ..., Standards and Health Protection Division, Office of Science and Technology, Mail Code: 4305T, Environmental... Elimination System (NPDES) permit limits. With this in mind, categories and entities that may ultimately be... of the water and water quality criteria necessary to protect those uses. States must submit any new...

  15. Certified standards and vertical coordination in aquaculture

    DEFF Research Database (Denmark)

    Trifkovic, Neda

    2014-01-01

    This paper explores the interaction between food standards and vertical coordination in the Vietnamese pangasius sector. For farmers and processors alike, the adoption of standards is motivated by a desire to improve market access by ensuring high quality supply. Instead of encouraging the applic......This paper explores the interaction between food standards and vertical coordination in the Vietnamese pangasius sector. For farmers and processors alike, the adoption of standards is motivated by a desire to improve market access by ensuring high quality supply. Instead of encouraging...... the application of standards and contract farming, processing companies prefer to vertically integrate primary production largely due to concerns over the stable supply of pangasius with satisfactory quality and safety attributes. These tendencies increase the market dominance of industrial farming and worsen...

  16. OZONE AMBIENT AIR QUALITY STANDARD HAS BENEFICIAL EFFECT ON PONDEROSA PINE IN CALIFORNIA

    Science.gov (United States)

    Ambient air quality standards and control strategies are implemented to protect humans and vegetation from adverse effects. However, to date there has not been a simple and objective method to determine if the standards and resultant control strategies have reduced O3 impacts on ...

  17. Development of quality standards in inflammatory bowel disease management and design of an evaluation tool of nursing care.

    Science.gov (United States)

    Torrejón, Antonio; Oltra, Lorena; Hernández-Sampelayo, Paloma; Marín, Laura; García-Sánchez, Valle; Casellas, Francesc; Alfaro, Noelia; Lázaro, Pablo; Vera, María Isabel

    2013-01-01

    nursing management of inflammatory bowel disease (IBD) is highly relevant for patient care and outcomes. However, there is evidence of substantial variability in clinical practices. The objectives of this study were to develop standards of healthcare quality for nursing management of IBD and elaborate the evaluation tool "Nursing Care Quality in IBD Assessment" (NCQ-IBD) based on these standards. a 178-item healthcare quality questionnaire was developed based on a systematic review of IBD nursing management literature. The questionnaire was used to perform two 2-round Delphi studies: Delphi A included 27 IBD healthcare professionals and Delphi B involved 12 patients. The NCQ-IBD was developed from the list of items resulting from both Delphi studies combined with the Scientific Committee´s expert opinion. the final NCQ-IBD consists of 90 items, organized in13 sections measuring the following aspects of nursing management of IBD: infrastructure, services, human resources, type of organization, nursing responsibilities, nurse-provided information to the patient, nurses training, annual audits of nursing activities, and nursing research in IBD. Using the NCQ-IBD to evaluate these components allows the rating of healthcare quality for nursing management of IBD into 4 categories: A (highest quality) through D (lowest quality). the use of the NCQ-IBD tool to evaluate nursing management quality of IBD identifies areas in need of improvement and thus contribute to an enhancement of care quality and reduction in clinical practice variations.

  18. Applying policy and health effects of air pollution in South Korea: focus on ambient air quality standards

    Science.gov (United States)

    Ha, Jongsik

    2014-01-01

    Objectives South Korea’s air quality standards are insufficient in terms of establishing a procedure for their management. The current system lacks a proper decision-making process and prior evidence is not considered. The purpose of this study is to propose a measure for establishing atmospheric environmental standards in South Korea that will take into consideration the health of its residents. Methods In this paper, the National Ambient Air Quality Standards (NAAQS) of the US was examined in order to suggest ways, which consider health effects, to establish air quality standards in South Korea. Up-to-date research on the health effects of air pollution was then reviewed, and tools were proposed to utilize the key results. This was done in an effort to ensure the reliability of the standards with regard to public health. Results This study showed that scientific research on the health effects of air pollution and the methodology used in the research have contributed significantly to establishing air quality standards. However, as the standards are legally binding, the procedure should take into account the effects on other sectors. Realistically speaking, it is impossible to establish standards that protect an entire population from air pollution. Instead, it is necessary to find a balance between what should be done and what can be done. Conclusions Therefore, establishing air quality standards should be done as part of an evidence-based policy that identifies the health effects of air pollution and takes into consideration political, economic, and social contexts. PMID:25300297

  19. [Quality management is associated with high quality services in health care].

    Science.gov (United States)

    Nielsen, Tenna Hassert; Riis, Allan; Mainz, Jan; Jensen, Anne-Louise Degn

    2013-12-09

    In these years, quality management has been the focus in order to meet high quality services for the patients in Danish health care. This article provides information on quality management and quality improvement and it evaluates its effectiveness in achieving better organizational structures, processes and results in Danish health-care organizations. Our findings generally support that quality management is associated with high quality services in health care.

  20. Economic Integration and Quality Standards in a Duopoly Model with Horizontal and Vertical Product Differentiation

    DEFF Research Database (Denmark)

    Nielsen, Jørgen Ulff-Møller; Hansen, Jørgen Drud

    This paper examines the effects of trade barriers on quality levels in a duopoly model for two countries with one producer in each country. The products are both vertically and horizontally differentiated. In absence of quality regulation, the two producers determine prices and quality levels...... standards are also ambiguous depending on the parameters of the model. Keywords: Vertical product differentiation; horizontal product differentiation; market integration; duopoly; minimum quality standard. JEL: F12, F13, F14....... product. On the unregulated markets, integration increases welfare in both countries if they are almost of similar size. However, if the countries are very asymmetrical with respect to size, market integration may harm welfare in the large country. Welfare effects by introduction of minimum quality...

  1. Setting ambient air quality standards for particulate matter

    International Nuclear Information System (INIS)

    McClellan, Roger O.

    2002-01-01

    Ambient air particulate matter (PM), unspecified as to chemical composition, is of concern because of its health effects. Air quality standards for PM have been established in many countries. The earliest standards were based on threshold models and use of a margin of safety. Initially, standards were based on the mass of total suspended material. In the 1980s a shift to a size-specific standard, PM 10 , began. PM 10 is the fraction of PM captured with 50% efficiency at 10 μm and greater efficiency at smaller sizes. In the late 1990s, standards were proposed for PM 2.5 , which is captured with 50% efficiency at 2.5 μm. The standards for PM are based almost exclusively on human epidemiological data, with laboratory animal and in vitro data used in a supporting role. During the 1990s, new statistical tools began to be used and demonstrated an association between increased PM and an increase in cardiorespiratory morbidity and mortality. The analyses are complicated by the effects of other pollutants such as ozone. Effects have been observed down to 10-20 μg of PM 10 per cubic meter, levels equal to or below background in many parts of the world. In many studies there has been no evidence of a threshold. In the absence of a threshold, a critical issue becomes how to determine how low is low enough? This paper reviews the current literature on PM health effects and suggests research avenues that may yield data which, combined with public policy considerations, may be able to address the issue of 'how low is low enough?'

  2. Key factors for a high-quality peritoneal dialysis program--the role of the PD team and continuous quality improvement.

    Science.gov (United States)

    Fang, Wei; Ni, Zhaohui; Qian, Jiaqi

    2014-06-01

    The proportion of end-stage renal disease (ESRD) patients on peritoneal dialysis (PD) has increased very fast in China over the last decade. Renji Hospital, affiliated with Shanghai Jiaotong University School of Medicine, is a recognized high-quality PD unit with a high PD utilization rate, excellent patient and technique survival (1-year and 5-year patient survival rate of 93% and 71%, and 1-year and 5-year technique survival of 96% and 82%, respectively), low peritonitis rate and a well-documented good quality of life of the treated patients. We believe that a dedicated and experienced PD team, a structured patient training program, continuous patient support, establishing and utilizing standardized protocols, starting PD with low dialysis dose, monitoring key performance indicators (KPIs), and continuous quality improvement (CQI) are the key factors underlying this successful PD program. Copyright © 2014 International Society for Peritoneal Dialysis.

  3. Standards for the culture and quality control of umbilical cord mesenchymal stromal cells for neurorestorative clinical application (2017

    Directory of Open Access Journals (Sweden)

    Ao Q

    2017-12-01

    Full Text Available Qiang Ao,1,* Juan Xiao,2,3,* Yanqiu Yu,4 Gengsheng Mao,2 Qingyan Zou,5 Wenyong Gao,2,3 Hongyun Huang2,3 On behalf of Neurorestoratology Professional Committee of Chinese Medical Doctor Association (Chinese Association of Neurorestoratology 1Department of Tissue Engineering, China Medical University, Shen Yang, 2Institute of Neurorestoratology, General Hospital of Armed Police Forces, Beijing, 3Cell Therapy Center, Beijing Hongtianji Neuroscience Academy, Beijing, 4Department of Pathophysiology, China Medical University, Shen Yang, 5Guangdong 999 Brain Hospital, Guangzhou, People’s Republic of China *These authors contributed equally to this work Abstract: Formulating common standards for the culture and quality control of umbilical cord mesenchymal stromal cells (MSCs is crucial for the standardization of clinical neurorestorative therapy. But to date, there have been no standardized guidelines for the culture and quality control of MSCs in neurorestorative clinical application. Based on a relatively comprehensive review of published clinical studies as well as the existing methods of MSC culture and quality control, the Chinese Association of Neurorestoratology has developed standards for the culture and quality control of umbilical cord MSCs which possess the potential in neurorestorative clinical application. These guidelines include standardized training and management procedures for laboratory operators; standardized use and management of materials and equipment; standardized collection, culture and proliferation of umbilical cord MSCs; standardized management for cell preservation, transport and related safeguard measures; as well as standardization of a clean environment, routine maintenance and related tests and examinations and so on. These guidelines represent the minimum required standards for the culture and quality control of umbilical cord MSCs for potential use in current neurorestorative clinical therapy, and will be further

  4. Study of relationship between radioactivity distribution, contamination burden and quality standard, accommodate energy of code river Yogyakarta

    International Nuclear Information System (INIS)

    Agus Taftazani and Muzakky

    2009-01-01

    Study of relationship between distribution, contamination burden of gross β radioactivity and natural radionuclide in water and sediment sample from 11 observation station Code river to quality standard and maximum capacity of Code river have been done. Natural radio nuclides identification and gross β radioactivity measurement of condensed water, dry and homogeneous sediment powder (past through 100 mesh sieve) samples have been done by using spectrometer and GM counter. Radioactivity data was analyzed descriptive with histogram to show the spreading pattern of data. Contamination burden data, quality standard and maximum capacity of river Code was to descriptive analyzed by line diagram to knowing relationship between contamination burden, quality standard, and maximum capacity of Code river. The observation of water and sediment at 11 observation station show that the emitter natural radionuclides: 210 Pb, 212 Pb, 214 Pb, 226 Ra, 208 Tl, 214 Bi, 228 Ac and 40 K were detected. The analytical result conclusion was that the pattern spread of average activity gross β and were increase from upstream to downstream of the Code river samples. Contamination burden, quality standard and maximum capacity of radionuclide activity of 210 Pb, 212 Pb, 226 Ra and 228 Ac were more smaller than quality standard of river water according to regulation of Nuclear Energy Regulatory Agency 02/Ka-BAPETEN/V-99 concerning quality standard of radioactivity. It’s mean that Code river still in good contamination burden for the four radionuclides. (author)

  5. [Study on quality standards of decoction pieces of salt Alpinia].

    Science.gov (United States)

    Li, Wenbing; Hu, Changjiang; Long, Lanyan; Huang, Qinwan; Xie, Xiuqiong

    2010-12-01

    To establish the quality criteria for decoction pieces of salt Alpinia. Decoction pieces of salt Alpinia were measured with moisture, total ash, acid-insoluble ash, water-extract and volatile oils according to the procedures recorded in the Chinese Pharmacopoeia 2010. The content of Nootkatone was determined by HPLC, and NaCl, by chloridion electrode method. We obtained results of total ash, acid-insoluble ash, water-extract and volatile oils of 10 batches of decoction pieces of salt Alpinia moisture; Meanwhile we set the HPLC and chloridion electrode method. This research established a fine quality standard for decoction pieces of salt Alpinia.

  6. Determination of quality standard of cemented radioactive wastes

    International Nuclear Information System (INIS)

    Johan, B.

    1997-01-01

    The standard determination of cemented low activity radioactive waste has been carried out. This study was intended to find the quality of immobilized product as a guaranty to the public and the environmental safety. As preliminary study, there parameters type have been studied i.e, the density, compressive strength and the leaching rate. By adopted the formulations of advanced country and field data, it can be concluded that the cementation waste should have the density, p, between 1.70 and 2.50 g.cm - 3, the compressive strength, S, between 20 and 50 N.mm - 2, the leaching rates R n between 1.70 x 10 - 2 and 2.50 x 10 - 3 g.cm - 2.day - 1 and after 150 days leaching time the leaching rate R n - 3 g.cm - 2.day - 1. This study is expected to be used to propose the Indonesian National Standard (INS) (author)

  7. E-Learning Quality Standards for Consumer Protection and Consumer Confidence: A Canadian Case Study in E-Learning Quality Assurance

    Science.gov (United States)

    Barker, Kathryn Chang

    2007-01-01

    Emerging concerns about quality of e-learning products and services animated a project in Canada to create quality standards that derived primarily from the needs of consumer, that could be used to guide the development and choice of e-learning at all levels of education and training, and that could be implemented in a simple manner. A set of…

  8. Green Roofs: Standardization and Quality Control of Processes in Green Construction

    Directory of Open Access Journals (Sweden)

    Korol Elena

    2017-01-01

    Full Text Available The article considers the problems of standardization and quality control of processes in the construction, improvement of integrated safety of buildings and the implementation of innovative green building technologies, the use of national standards as well as international rating systems for green buildings evaluation. This is one of the priority directions in development of the modern construction. The aim of this study is the analysis of the green roof systems and international standards, which were carried out in the green building industry. The authors have studied traditional and innovative solutions of rational using natural resources and energy, the green roof system with integration of supported solar and wind energy collecting and converting devices and of irrigation system. Some studies provide evidence for the benefits of the modular green roof system in urban green space with microclimate differences. This article presents a new research which advances our knowledge of the economic and environmental services provided by the green roof system. Research reported here also considers the analysis of the Russian and international legislation of the quality control of processes in green construction.

  9. 77 FR 74449 - Water Quality Standards for the State of Florida's Lakes and Flowing Waters; Proposed Rule; Stay

    Science.gov (United States)

    2012-12-14

    ... Water Quality Standards for the State of Florida's Lakes and Flowing Waters; Proposed Rule; Stay AGENCY... Protection Agency (EPA) proposes to temporarily stay our regulation the ``Water Quality Standards for the... Information Does this action apply to me? Citizens concerned with water quality in Florida may be interested...

  10. Labor Standards and Quality of Employment in Latin America

    Directory of Open Access Journals (Sweden)

    Graciela Bensusán

    2009-07-01

    Full Text Available This paper discusses the role of national and international labor standards and refers to the need to curb the deterioration of employment quality and to promote decent work in the context of strong competitive pressures, network companies and productive chains spread throughout the world, from a Latin American perspective. It reviews the number of ratifications of fundamental international agreements' and the problems involved in their implementation; the relation between these shortcomings and the quality of jobs, as well as the advantages and disadvantages of different alternatives aimed at halting job deterioration. It concludes by pointing out the importance of national legislation and public tools aimed at improved enforcement, in the absence of global and international coercive mechanisms.

  11. The effect of the SQUIRE (Standards of QUality Improvement Reporting Excellence) guidelines on reporting standards in the quality improvement literature: a before-and-after study.

    Science.gov (United States)

    Howell, Victoria; Schwartz, Amanda Eva; O'Leary, James Daniel; Mc Donnell, Conor

    2015-06-01

    The SQUIRE (Standards of QUality Improvement Reporting Excellence) guidelines were developed to improve the reporting of quality improvement (QI) projects. The effect of the guidelines on the completeness of reporting in the QI literature is unknown. Our primary objective was to determine if the completeness of reporting in the QI literature has been improved[OUP_CE13] since the introduction of the SQUIRE guidelines. We performed a before-and-after evaluation of QI articles selected from four prominent journals of healthcare quality. Twenty-five articles published in each of two time periods (2006-2008 and 2010-2011) were confirmed to be QI projects using a standardised definition and were independently evaluated by two investigators as an interim evaluation of a planned larger sample. Articles were assessed using 50 statements of the SQUIRE guidelines, and the overall change in the completeness of reporting between the two groups was determined. The value of pimprovement observed in the completeness of reporting of QI projects after the publication of the SQUIRE guidelines, and the study was stopped early. There is potential for improvement in reporting standards, particularly for those guideline items or statements specific to QI projects. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. 75 FR 61413 - Notice of Availability of Biotechnology Quality Management System Audit Standard and Evaluation...

    Science.gov (United States)

    2010-10-05

    ...] Notice of Availability of Biotechnology Quality Management System Audit Standard and Evaluation of... the public that the Animal and Plant Health Inspection Service has developed an audit standard for its biotechnology compliance assistance program. The audit standard, which was made available in draft form for...

  13. Profiling and sorting Mangifera Indica morphology for quality attributes and grade standards using integrated image processing algorithms

    Science.gov (United States)

    Balbin, Jessie R.; Fausto, Janette C.; Janabajab, John Michael M.; Malicdem, Daryl James L.; Marcelo, Reginald N.; Santos, Jan Jeffrey Z.

    2017-06-01

    Mango production is highly vital in the Philippines. It is very essential in the food industry as it is being used in markets and restaurants daily. The quality of mangoes can affect the income of a mango farmer, thus incorrect time of harvesting will result to loss of quality mangoes and income. Scientific farming is much needed nowadays together with new gadgets because wastage of mangoes increase annually due to uncouth quality. This research paper focuses on profiling and sorting of Mangifera Indica using image processing techniques and pattern recognition. The image of a mango is captured on a weekly basis from its early stage. In this study, the researchers monitor the growth and color transition of a mango for profiling purposes. Actual dimensions of the mango are determined through image conversion and determination of pixel and RGB values covered through MATLAB. A program is developed to determine the range of the maximum size of a standard ripe mango. Hue, light, saturation (HSL) correction is used in the filtering process to assure the exactness of RGB values of a mango subject. By pattern recognition technique, the program can determine if a mango is standard and ready to be exported.

  14. Guidelines for preparing high school psychology teachers: course-based and standards-based approaches.

    Science.gov (United States)

    2013-01-01

    Psychology is one of the most popular elective high school courses. The high school psychology course provides the foundation for students to benefit from psychological perspectives on personal and contemporary issues and learn the rules of evidence and theoretical frameworks of the discipline. The guidelines presented here constitute the second of two reports in this issue of the American Psychologist (January 2013) representing recent American Psychological Association (APA) policies that support high-quality instruction in the teaching of high school psychology. These guidelines, aligned to the standards presented in the preceding report, describe models for the preparation of preservice psychology teachers. The two reports together demonstrate the rigor and competency that should be expected in psychology instruction at the high school level.

  15. Student Writing Accepted as High-Quality Responses to Analytic Text-Based Writing Tasks

    Science.gov (United States)

    Wang, Elaine; Matsumura, Lindsay Clare; Correnti, Richard

    2018-01-01

    Literacy standards increasingly emphasize the importance of analytic text-based writing. Little consensus exists, however, around what high-quality student responses should look like in this genre. In this study, we investigated fifth-grade students' writing in response to analytic text-based writing tasks (15 teachers, 44 writing tasks, 88 pieces…

  16. Identification of Water Quality Significant Parameter with Two Transformation/Standardization Methods on Principal Component Analysis and Scilab Software

    Directory of Open Access Journals (Sweden)

    Jovan Putranda

    2016-09-01

    Full Text Available Water quality monitoring is prone to encounter error on its recording or measuring process. The monitoring on river water quality not only aims to recognize the water quality dynamic, but also to evaluate the data to create river management policy and water pollution in order to maintain the continuity of human health or sanitation requirement, and biodiversity preservation. Evaluation on water quality monitoring needs to be started by identifying the important water quality parameter. This research objected to identify the significant parameters by using two transformation or standardization methods on water quality data, which are the river Water Quality Index, WQI (Indeks Kualitas Air, Sungai, IKAs transformation or standardization method and transformation or standardization method with mean 0 and variance 1; so that the variability of water quality parameters could be aggregated with one another. Both of the methods were applied on the water quality monitoring data which its validity and reliability have been tested. The PCA, Principal Component Analysis (Analisa Komponen Utama, AKU, with the help of Scilab software, has been used to process the secondary data on water quality parameters of Gadjah Wong river in 2004-2013, with its validity and reliability has been tested. The Scilab result was cross examined with the result from the Excel-based Biplot Add In software. The research result showed that only 18 from total 35 water quality parameters that have passable data quality. The two transformation or standardization data methods gave different significant parameter type and amount result. On the transformation or standardization mean 0 variances 1, there were water quality significant parameter dynamic to mean concentration of each water quality parameters, which are TDS, SO4, EC, TSS, NO3N, COD, BOD5, Grease Oil and NH3N. On the river WQI transformation or standardization, the water quality significant parameter showed the level of

  17. 40 CFR Appendix S to Part 50 - Interpretation of the Primary National Ambient Air Quality Standards for Oxides of Nitrogen...

    Science.gov (United States)

    2010-07-01

    ... Ambient Air Quality Standards for Oxides of Nitrogen (Nitrogen Dioxide) S Appendix S to Part 50 Protection... National Ambient Air Quality Standards for Oxides of Nitrogen (Nitrogen Dioxide) 1. General (a) This... national ambient air quality standards for oxides of nitrogen as measured by nitrogen dioxide (“NO2 NAAQS...

  18. Could Innovation also Emerge from the Public Sector? Creating an ISO-like Judiciary Quality Management Standard.

    Directory of Open Access Journals (Sweden)

    Rodrigo Murillo

    2013-10-01

    Full Text Available This paper explores the conceptual differences between the GICA-Justicia Project initiative and other available models, process performance guidelines, and tools. Comparison was basically carried out through a review of specialized literature, papers, and reports; semi-structured interviews and focus groups with experts in the judicial quality assurance field from different countries; and applying the authors’ experience as technical counterparts in the GICA-Justicia Project (co-authoring a Quality Management Standard and training/auditing during the Quality Management System deployment and accreditation stages.  The paper is meant to unveil how the GICA-Justicia Quality Management Model and the GICA-Justicia Quality Management Standard, as  GICA-Justicia Project by-products, combine to create an innovative process performance approach to quality assurance in judicial environments.

  19. Study on the Introduction of High-Quality Educational Resources for Sino-Foreign Cooperative Education

    Science.gov (United States)

    Jinhui, Lin

    2016-01-01

    In Sino-foreign cooperative education, high-quality introduced educational resources must benefit the growth and development of students, facilitate the school's capacity building and the improvement of overall educational standards, and promote national socioeconomic development. It is necessary to establish and perfect the various working…

  20. The Implementation of a Quality Management Standard in a Food SME: A Network Learning Perspective

    Directory of Open Access Journals (Sweden)

    Zam-Zam Abdirahman

    2013-02-01

    Full Text Available In the modern agrifood economies, the development of quality management standards is crucial, and food small and medium enterprises (SMEs usually face difficulties in implementing them. In this context, the aim of the article is two‐fold. Firstly it is to craft an original analytical framework in line with the literature on innovation networks and related learning effects specifically devoted to the study of quality management standards implementation. Secondly the objective of the article is to apply this framework to a specific food SME case in order to test it and to identify the key network learningeffects that occur during the implementation of a quality management standard, namely the ISO 22000 standard for food safety. From this research, the practical output will be to propose tools to enhance food SMEs’ innovative capacity, through an improvement of their insertion in active formal and/or informal innovation networks. These specific tools will be especially targeted towards the strengthening of learning processes between the SME and the partners involved in the implementation.

  1. High-speed nuclear quality pulse height analyzer for synchrotron-based applications

    International Nuclear Information System (INIS)

    Beche, Jean-Francois; Bucher, Jerome J.; Fabris, Lorenzo; Riot, Vincent J.

    2001-01-01

    A high throughput Pulse Height Analyzer system for synchrotron-based applications requiring high resolution, high processing speed and low dead time has been developed. The system is comprised of a 120ns 12-bit nuclear quality Analog to Digital converter with a self-adaptive fast peak detector-stretcher and a custom-made fast histogramming memory module that records and processes the digitized data. The histogramming module is packaged in a VME or VXI compatible interface. Data is transferred through a fast optical link from the memory interface to a computer. A dedicated data acquisition program matches the hardware characteristics of the histogramming memory module. The data acquisition system allows for two data collection modes: ''standard'' data acquisition mode where the data is accumulated and read in synchronization with an external trigger and ''live'' data acquisition mode where the system operates as a standard Pulse Height Analyzer. The acquisition, standard or live, can be performed on several channels simultaneously. A two-channel prototype has been demonstrated at the Stanford Synchrotron Radiation Laboratory accelerator in conjunction with an X-ray Fluorescence Absorption Spectroscopy experiment. A detailed description of the entire system is given and experimental data is shown

  2. Head-To-Head Comparison Between High- and Standard-b-Value DWI for Detecting Prostate Cancer: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup

    2018-01-01

    The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.

  3. Quality control and standardization of forearm X-ray osteodensitometry

    International Nuclear Information System (INIS)

    Boyanov, M.

    2000-01-01

    Quality control (QC) has an essential practical bearing on the proper function of the equipment used for bone density measurement. Special attention is likewise focused on the issue of standardization of the results afforded by different osteodensitometry instruments. It is the purpose of the study to assay QC of a single-energy x-ray forearm osteodensitometry unit DTX-100 covering a 3 year period, and compare the data on bone mineral density (BMD) produced by three different devices. Long-term BMD reproducibility in vitro, expressed as coefficient of variation, amounts to 0.55 per cent. Except for a two week period, no deviation from the normal function of the instrument is documented. Failing to comply with the manufacturer's instructions may discredit QC efficacy. On comparative assessment of the results produced by different osteodensitometers, differences in vivo may reach up to 1.2 standard deviation. Definite regions of special interest, feasible for comparison, are recommended. In conclusion special emphasis is laid on the necessity of performing through QC, measurement results standardization and accreditation of a reference osteodensitometry center

  4. Neurorestorative clinical application standards for the culture and quality control of olfactory ensheathing cells

    Directory of Open Access Journals (Sweden)

    Xiao J

    2017-09-01

    Full Text Available Juan Xiao,1,2 Lin Chen,3 Gengsheng Mao,1 Wenyong Gao,1,2 Ming Lu,4 Xijing He,5 Hongyun Huang1,2 On behalf of the Neurorestoratology Professional Committee of Chinese Medical Doctors Association (Chinese Association of Neurorestoratology 1Institute of Neurorestoratology, The General Hospital of Chinese People’s Armed Police Forces, Beijing, People’s Republic of China; 2Cell Therapy Center, Beijing Hongtianji Neuroscience Academy, Beijing, People’s Republic of China; 3Department of Neurosurgery, Tsinghua University Yuquan Hospital, Beijing, People’s Republic of China; 4Department of Neurosurgery, 163 Hospital of PLA (Second Affiliated Hospital of Hunan Normal University, Changsha, Hunan Province, People’s Republic of China; 5Department of Orthopedics, Second Affiliated Hospital of Xi’an Jiaotong University, Xian, Shanxi Provine, People’s Republic of China Abstract: Olfactory ensheathing cells (OECs are a novel type of glial cell that can perform and promote many neurorestorative processes in vivo after transplant. To date, dozens of preclinical and clinical studies have confirmed that OECs have unique restoring effects in animal models and human subjects with neurological degeneration or damage, such as spinal cord injury, stroke, cerebral palsy, traumatic brain injury, and motor neuron disease (amyotrophic lateral sclerosis. To ensure the safety and effectiveness of clinical applications utilizing this type of cell, it is important to standardize cell-culture and quality-control processes. Based on a comprehensive review of published clinical studies, as well as existing methods of OEC culture and quality control currently utilized by hospitals and biomedical enterprises, the Chinese Association of Neurorestoratology has developed a set of standards for the culture and quality control of olfactory ensheathing cells for use in clinical applications. These guidelines include standardized training and management procedures for

  5. Establishment of a Quality Management System Based on ISO 9001 Standard in a Public Service Fungal Culture Collection

    Science.gov (United States)

    Simões, Marta F.; Dias, Nicolina; Santos, Cledir; Lima, Nelson

    2016-01-01

    Collaborations between different Microbiological Resource Centres (mBRCs) and ethical sourcing practices are mandatory to guarantee biodiversity conservation, successful and sustainable preservation and fair share of benefits that arise from the use of genetic resources. Since microbial Culture Collections (CCs) are now engaged in meeting high quality operational standards, they are facing the challenge of establishing quality control criteria to certify their biological materials. The authentication/certification of strains is nowadays a demand from the bioeconomy sector for the global operation of mBRCs. The achievement of consistent quality assurance and trust within the mBRCs and microbial CCs context is a dynamic and never-ending process. A good option to facilitate that process is to implement a Quality Management System (QMS) based on the ISO 9001 standard. Here, we report a detailed description of all the steps taken for the QMS implementation at the Portuguese CC of filamentous fungi: Micoteca da Universidade do Minho (MUM). Our aim is to provide guidelines for the certification of other CCs, so that they can also enhance the search and choice of the most consistent, reliable, and effective operating methods, with assured procedures and validation of preservation; and guarantee trustworthy relations with all stakeholders. PMID:27681915

  6. Establishment of a Quality Management System Based on ISO 9001 Standard in a Public Service Fungal Culture Collection

    KAUST Repository

    Simoes, Marta

    2016-06-22

    Collaborations between different Microbiological Resource Centres (mBRCs) and ethical sourcing practices are mandatory to guarantee biodiversity conservation, successful and sustainable preservation and fair share of benefits that arise from the use of genetic resources. Since microbial Culture Collections (CCs) are now engaged in meeting high quality operational standards, they are facing the challenge of establishing quality control criteria to certify their biological materials. The authentication/certification of strains is nowadays a demand from the bioeconomy sector for the global operation of mBRCs. The achievement of consistent quality assurance and trust within the mBRCs and microbial CCs context is a dynamic and never-ending process. A good option to facilitate that process is to implement a Quality Management System (QMS) based on the ISO 9001 standard. Here, we report a detailed description of all the steps taken for the QMS implementation at the Portuguese CC of filamentous fungi: Micoteca da Universidade do Minho (MUM). Our aim is to provide guidelines for the certification of other CCs, so that they can also enhance the search and choice of the most consistent, reliable, and effective operating methods, with assured procedures and validation of preservation; and guarantee trustworthy relations with all stakeholders.

  7. Establishment of a Quality Management System Based on ISO 9001 Standard in a Public Service Fungal Culture Collection.

    Science.gov (United States)

    Simões, Marta F; Dias, Nicolina; Santos, Cledir; Lima, Nelson

    2016-06-22

    Collaborations between different Microbiological Resource Centres (mBRCs) and ethical sourcing practices are mandatory to guarantee biodiversity conservation, successful and sustainable preservation and fair share of benefits that arise from the use of genetic resources. Since microbial Culture Collections (CCs) are now engaged in meeting high quality operational standards, they are facing the challenge of establishing quality control criteria to certify their biological materials. The authentication/certification of strains is nowadays a demand from the bioeconomy sector for the global operation of mBRCs. The achievement of consistent quality assurance and trust within the mBRCs and microbial CCs context is a dynamic and never-ending process. A good option to facilitate that process is to implement a Quality Management System (QMS) based on the ISO 9001 standard. Here, we report a detailed description of all the steps taken for the QMS implementation at the Portuguese CC of filamentous fungi: Micoteca da Universidade do Minho (MUM). Our aim is to provide guidelines for the certification of other CCs, so that they can also enhance the search and choice of the most consistent, reliable, and effective operating methods, with assured procedures and validation of preservation; and guarantee trustworthy relations with all stakeholders.

  8. A quality control of proteomic experiments based on multiple isotopologous internal standards

    Directory of Open Access Journals (Sweden)

    Adele Bourmaud

    2015-09-01

    Full Text Available The harmonization of proteomics experiments facilitates the exchange and comparison of results. The definition of standards and metrics ensures reliable and consistent data quality. An internal quality control procedure was developed to assess the different steps of a proteomic analysis workflow and perform a system suitability test. The method relies on a straightforward protocol using a simple mixture of exogenous proteins, and the sequential addition of two sets of isotopically labeled peptides added to reference samples. This internal quality control procedure was applied to plasma samples to demonstrate its easy implementation, which makes it generic for most proteomics applications.

  9. Comparison of myocardial perfusion imaging between the new high-speed gamma camera and the standard anger camera

    International Nuclear Information System (INIS)

    Tanaka, Hirokazu; Chikamori, Taishiro; Hida, Satoshi

    2013-01-01

    Cadmium-zinc-telluride (CZT) solid-state detectors have been recently introduced into the field of myocardial perfusion imaging. The aim of this study was to prospectively compare the diagnostic performance of the CZT high-speed gamma camera (Discovery NM 530c) with that of the standard 3-head gamma camera in the same group of patients. The study group consisted of 150 consecutive patients who underwent a 1-day stress-rest 99m Tc-sestamibi or tetrofosmin imaging protocol. Image acquisition was performed first on a standard gamma camera with a 15-min scan time each for stress and for rest. All scans were immediately repeated on a CZT camera with a 5-min scan time for stress and a 3-min scan time for rest, using list mode. The correlations between the CZT camera and the standard camera for perfusion and function analyses were strong within narrow Bland-Altman limits of agreement. Using list mode analysis, image quality for stress was rated as good or excellent in 97% of the 3-min scans, and in 100% of the ≥4-min scans. For CZT scans at rest, similarly, image quality was rated as good or excellent in 94% of the 1-min scans, and in 100% of the ≥2-min scans. The novel CZT camera provides excellent image quality, which is equivalent to standard myocardial single-photon emission computed tomography, despite a short scan time of less than half of the standard time. (author)

  10. 76 FR 22665 - Release of Final Document Related to the Review of the National Ambient Air Quality Standards for...

    Science.gov (United States)

    2011-04-22

    ... criteria. The revised air quality criteria reflect advances in scientific knowledge on the effects of the... National Ambient Air Quality Standards, contains staff analyses of the scientific bases for alternative... Document Related to the Review of the National Ambient Air Quality Standards for Particulate Matter AGENCY...

  11. 40 CFR Appendix R to Part 50 - Interpretation of the National Ambient Air Quality Standards for Lead

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Interpretation of the National Ambient Air Quality Standards for Lead R Appendix R to Part 50 Protection of Environment ENVIRONMENTAL.... 50, App. R Appendix R to Part 50—Interpretation of the National Ambient Air Quality Standards for...

  12. Construction of High-Quality Camel Immune Antibody Libraries.

    Science.gov (United States)

    Romão, Ema; Poignavent, Vianney; Vincke, Cécile; Ritzenthaler, Christophe; Muyldermans, Serge; Monsion, Baptiste

    2018-01-01

    Single-domain antibodies libraries of heavy-chain only immunoglobulins from camelids or shark are enriched for high-affinity antigen-specific binders by a short in vivo immunization. Thus, potent binders are readily retrieved from relatively small-sized libraries of 10 7 -10 8 individual transformants, mostly after phage display and panning on a purified target. However, the remaining drawback of this strategy arises from the need to generate a dedicated library, for nearly every envisaged target. Therefore, all the procedures that shorten and facilitate the construction of an immune library of best possible quality are definitely a step forward. In this chapter, we provide the protocol to generate a high-quality immune VHH library using the Golden Gate Cloning strategy employing an adapted phage display vector where a lethal ccdB gene has to be substituted by the VHH gene. With this procedure, the construction of the library can be shortened to less than a week starting from bleeding the animal. Our libraries exceed 10 8 individual transformants and close to 100% of the clones harbor a phage display vector having an insert with the length of a VHH gene. These libraries are also more economic to make than previous standard approaches using classical restriction enzymes and ligations. The quality of the Nanobodies that are retrieved from immune libraries obtained by Golden Gate Cloning is identical to those from immune libraries made according to the classical procedure.

  13. Ideology and Audit Culture: Standardized Service Quality Surveys in Academic Libraries

    Science.gov (United States)

    Lilburn, Jeff

    2017-01-01

    This article examines the relationship between the standardized service quality survey LibQUAL+ and the rise of audit culture. Recent scholarship examining assessment and accountability systems and the ideological principles driving their implementation in higher education raises concerns about the impact these systems have on teaching, learning,…

  14. Standard Review Plan for Environmental Restoration Program Quality Management Plans

    International Nuclear Information System (INIS)

    1993-12-01

    The Department of Energy, Richland Operations Office (RL) Manual Environmental Restoration Program Quality System Requirements (QSR) for the Hanford Site, defines all quality requirements governing Hanford Environmental Restoration (ER) Program activities. The QSR requires that ER Program participants develop Quality Management Plans (QMPs) that describe how the QSR requirements will be implemented for their assigned scopes of work. This standard review plan (SRP) describes the ER program participant responsibilities for submittal of QMPs to the RL Environmental Restoration Division for review and the RL methodology for performing the reviews of participant QMPS. The SRP serves the following functions: acts as a guide in the development or revision of QMPs to assure that the content is complete and adequate; acts as a checklist to be used by the RL staff in their review of participant QMPs; acts as an index or matrix between the requirements of the QSR and implementing methodologies described in the QMPs; decreases the time and subjectivity of document reviews; and provides a formal, documented method for describing exceptions, modifications, or waivers to established ER Program quality requirements

  15. Concept of Draft International Standard for a Unified Approach to Space Program Quality Assurance

    Science.gov (United States)

    Stryzhak, Y.; Vasilina, V.; Kurbatov, V.

    2002-01-01

    For want of the unified approach to guaranteed space project and product quality assurance, implementation of many international space programs has become a challenge. Globalization of aerospace industry and participation of various international ventures with diverse quality assurance requirements in big international space programs requires for urgent generation of unified international standards related to this field. To ensure successful fulfillment of space missions, aerospace companies should design and process reliable and safe products with properties complying or bettering User's (or Customer's) requirements. Quality of the products designed or processed by subcontractors (or other suppliers) should also be in compliance with the main user (customer)'s requirements. Implementation of this involved set of unified requirements will be made possible by creating and approving a system (series) of international standards under a generic title Space Product Quality Assurance based on a system consensus principle. Conceptual features of the baseline standard in this system (series) should comprise: - Procedures for ISO 9000, CEN and ECSS requirements adaptation and introduction into space product creation, design, manufacture, testing and operation; - Procedures for quality assurance at initial (design) phases of space programs, with a decision on the end product made based on the principle of independence; - Procedures to arrange incoming inspection of products delivered by subcontractors (including testing, audit of supplier's procedures, review of supplier's documentation), and space product certification; - Procedures to identify materials and primary products applied; - Procedures for quality system audit at the component part, primary product and materials supplier facilities; - Unified procedures to form a list of basic performances to be under configuration management; - Unified procedures to form a list of critical space product components, and unified

  16. [Implementation of the technical requirements of the UNE-EN-ISO 15189 quality standard in a mycobacterial laboratory].

    Science.gov (United States)

    Guna Serrano, M del Remedio; Ocete Mochón, M Dolores; Lahiguera, M José; Bresó, M Carmen; Gimeno Cardona, Concepción

    2013-02-01

    The UNE-EN-ISO 15189:2007 standard defines the requirements for quality and competence that must be met by medical laboratories. These laboratories should use this international standard to develop their own quality management systems and to evaluate their own competencies; in turn, this standard will be used by accreditation bodies to confirm or recognize the laboratories' competence. In clinical microbiology laboratories, application of the standard implies the implementation of the technical and specific management requirements that must be met to achieve optimal quality when carrying out microbiological tests. In Spain, accreditation is granted by the Spanish Accreditation Body (Entidad Nacional de Acreditación). This review aims to discuss the practical application of the standard's technical requirements in mycobacterial laboratory. Firstly, we define the scope of accreditation. Secondly, we specify how the items of the standard on personnel management, control of equipment, environmental facilities, method validation, internal controls and customer satisfaction surveys were developed and implemented in our laboratory. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  17. An application of the IAEA GCS-R-3 Standard in Nuclear Quality Management System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. I.; Juhn, P. E. [TUEV SUED Korea, Seoul (Korea, Republic of); Kwon, M. J. [TUEV SUED KOCEN, Seoul (Korea, Republic of)

    2012-03-15

    IAEA GCS-R-3 Standard (2006) is intended to help nuclear community establishing a nuclear quality management system that integrates such 6 elements as safety, health, environment, security, quality and economics. In the present paper, the management principles of GCS-R-3 Standard are compared with those of ISO 9001 and ASME N/A-1 Codes and Standards. The paper also summarizes the worldwide survey on application of GS-R-3, which was conducted by the TUEV SUED Korea in 2011. The result concludes that the top priority should be given to safety upon which the management system must be based, in proper coordination with other 5 elements to enhance nuclear safety, in particular after Fukushima Dais-Ici nuclear power accidents on 11{sup th} March 2011 in Japan.

  18. Development of standardized laboratory methods and quality processes for a phase III study of the RTS, S/AS01 candidate malaria vaccine

    Directory of Open Access Journals (Sweden)

    Carter Terrell

    2011-08-01

    Full Text Available Abstract Background A pivotal phase III study of the RTS,S/AS01 malaria candidate vaccine is ongoing in several research centres across Africa. The development and establishment of quality systems was a requirement for trial conduct to meet international regulatory standards, as well as providing an important capacity strengthening opportunity for study centres. Methods Standardized laboratory methods and quality assurance processes were implemented at each of the study centres, facilitated by funding partners. Results A robust protocol for determination of parasite density based on actual blood cell counts was set up in accordance with World Health Organization recommendations. Automated equipment including haematology and biochemistry analyzers were put in place with standard methods for bedside testing of glycaemia, base excess and lactacidaemia. Facilities for X-rays and basic microbiology testing were also provided or upgraded alongside health care infrastructure in some centres. External quality assurance assessment of all major laboratory methods was established and method qualification by each laboratory demonstrated. The resulting capacity strengthening has ensured laboratory evaluations are conducted locally to the high standards required in clinical trials. Conclusion Major efforts by study centres, together with support from collaborating parties, have allowed standardized methods and robust quality assurance processes to be put in place for the phase III evaluation of the RTS, S/AS01 malaria candidate vaccine. Extensive training programmes, coupled with continuous commitment from research centre staff, have been the key elements behind the successful implementation of quality processes. It is expected these activities will culminate in healthcare benefits for the subjects and communities participating in these trials. Trial registration Clinicaltrials.gov NCT00866619

  19. A case study: forming an effective quality management system according to ISO 9000 standards

    OpenAIRE

    Zağyapan, Orhan

    1995-01-01

    Ankara : The Faculty of Management and the Graduate School of Business Administration of Bilkent Univ., 1995. Thesis (Master's) -- Bilkent University, 1995. Includes bibliographical references leaves 87-88 In today's world, companies which adopt themselves to certain internationally recognized standards are one step ahead of their competitors. ISO 9000 Quality System Standards captured the most attention among all. The aim of the standard is to provide an international bench...

  20. Fabricating High-Quality 3D-Printed Alloys for Dental Applications

    Directory of Open Access Journals (Sweden)

    Min-Ho Hong

    2017-07-01

    Full Text Available Metal additive manufacturing (AM, especially selective laser melting (SLM, has been receiving particular attention because metallic functional structures with complicated configurations can be effectively fabricated using the technique. However, there still exist some future challenges for the fabrication of high-quality SLM products for dental applications. First, the surface quality of SLM products should be further improved by standardizing the laser process parameters or by appropriately post-treating the surface. Second, it should be guaranteed that dental SLM restorations have good dimensional accuracy and, in particular, a good marginal fit. Third, a definitive standard regarding building and scanning strategies, which affect the anisotropy, should be established to optimize the mechanical properties and fatigue resistance of SLM dental structures. Fourth, the SLM substructure’s bonding and support to veneering ceramic should be further studied to facilitate the use of esthetic dental restorations. Finally, the biocompatibility of SLM dental alloys should be carefully examined and improved to minimize the potential release of toxic metal ions from the alloys. Future research of SLM should focus on solving the above challenges, as well as on fabricating dental structures with “controlled” porosity.

  1. Development of standard reference samples for diffractometry

    International Nuclear Information System (INIS)

    Galvao, Antonio de Sant'Ana

    2011-01-01

    In this work, samples of standard reference materials for diffractometry of polycrystals were developed. High-purity materials were submitted to mechanical and thermal treatments in order to present the adequate properties to be used as high-quality standard reference materials for powder diffraction, comparable to the internationally recognized produced by the USA National Institute of Standards and Technology NIST, but at lower costs. The characterization of the standard materials was performed by measurements in conventional X-ray diffraction diffractometers, high resolution neutron diffraction and high-resolution synchrotron diffraction. The lattice parameters were calculated by extrapolation of the values obtained from each X-ray reflection against cos 2 θ by the Least-Squares Method. The adjustments were compared to the values obtained by the Rietveld Method, using program GSAS. The materials thus obtained were the α-alumina, yttrium oxide, silicon, cerium oxide, lanthanum hexaboride and lithium fluoride. The standard reference materials produced present quality similar or, in some cases, superior to the standard reference materials produced and commercialized by the NIST. (author)

  2. Availability of Quality Standards in the Special Education Program at Majmaah University - Saudi Arabia, from the Perspectives of Teachers and 8th level Students

    Directory of Open Access Journals (Sweden)

    Omar Khalil Mousa Atiyat

    2017-11-01

    Full Text Available The aim of the study was to assess to what extent the quality standards in the Special Education Program at Majmaah University, were available from the point of view of faculty members and 8th level students who were expected to graduate, in the light of a number of variables. To achieve the objectives of the study, the researcher  used a  descriptive survey method and developed a questionnaire, consisting of six areas:  (objectives of the program, teaching methods, and curriculum,  students’ evaluation, facilities and services, and field training. The study sample consisted of all faculty members at the Department of Special Education in the College of Education, totaling (42 faculty members, and (62 8th Level students who were expected to graduate in the academic year 2015 / 2016.  The study results revealed the availability of quality standards in the program to a high degree from the point of view of faculty members, and in all the areas of the questionnaire, with a slight variation between these areas  "standards ". The standard “objectives of the program” ranked first, while the standard “facilities and services” ranked last. From the students’ perspective, on the other hand, the results indicated that  quality standards, which are related to program objectives only, were available in the program  to a high degree. In other areas of the questionnaire, students’ perspectives had a medium degree. The results of the study did not show any significant differences at the level (α = 0.05 between the means of the faculty members perspectives, attributed to the variables (gender, years of experience, but there were statistically significant differences (α=0.05, attributed to the impact of level of education, in favor of MA and PhD holders. Also, the results did not reveal any significant differences at the level (α = 0.05 between the means of the students’ perspectives due to the variable (GPA, gender. Keywords: Graduate

  3. Standards for the High School Psychology Course. ERIC Digest.

    Science.gov (United States)

    Morganett, L. Lee

    The latest contribution to the content standards boom that began in the 1990s comes from the American Psychological Association (APA), which recently published "National Standards for the Teaching of High School Psychology." This Digest discusses: (1) the origin and purposes of the project to develop standards for high school psychology…

  4. Teaching High School Physical Education According to National Standards: The 6 Verbs of Success--Demonstrate, Understand, Participate, Achieve, Exhibit and Value

    Science.gov (United States)

    Bert, Greg

    2010-01-01

    The six national content standards from NASPE define what a student should know and be able to do as a result of a high quality physical education program. The "NASPE SIX" serve as a North Star to guide teachers as they prepare and implement programs. Simply stated, the NASPE Standards for Physical Education are all about six simple…

  5. Making Retail Supply Chains Sustainable: Upgrading Opportunities for Developing Country Suppliers under Voluntary Quality Standards

    NARCIS (Netherlands)

    J.C.A.C. van Wijk (Jeroen); M. Danse (Myrtille); R.J.M. van Tulder (Rob)

    2008-01-01

    textabstractThis paper examines the sustainability claims of private quality standards, voluntary adopted by supermarket to improve the quality of products in respect of food safety, and environmental and social sustainability. The concept of ‘sustainability’ is defined as the opportunity for

  6. Quality control provisions applied in the preparation and characterization of Pu-bearing PERLA standards

    International Nuclear Information System (INIS)

    Guardini, S.; Guzzi, G.; Mousty, F.; Kuhn, E.; Regge, P. de

    1990-01-01

    This report describes the work carried out at the different laboratories where Pu-bearing samples, intended for use as reference materials for NDA measurements, were prepared and characterized. The standard samples were produced from PuO2 and MOX batches of different nature and are at present stored in the PERLA facility at the Institute for Safety Technology of the JRC Ispra and are available for use. Particular attention is paid to the quality control procedures adopted during the sampling, preparation and analysis of the material, to fulfil the requirements established a priori for NDA standards to be used in Safeguards. The results of the different quality control checks are presented and discussed. The drawings of the containers for the PuO2 and MOX powders and of the special fuel rods for MOX pellets are also presented. This report is intended for use in conjunction with the PERLA STANDARD CERTIFICATES which are issued for each type of material considered, and gives to the user the possibility of tracing all analytical data back to primary standards

  7. High-quality compressive ghost imaging

    Science.gov (United States)

    Huang, Heyan; Zhou, Cheng; Tian, Tian; Liu, Dongqi; Song, Lijun

    2018-04-01

    We propose a high-quality compressive ghost imaging method based on projected Landweber regularization and guided filter, which effectively reduce the undersampling noise and improve the resolution. In our scheme, the original object is reconstructed by decomposing of regularization and denoising steps instead of solving a minimization problem in compressive reconstruction process. The simulation and experimental results show that our method can obtain high ghost imaging quality in terms of PSNR and visual observation.

  8. Practical considerations for obtaining high quality quantitative computed tomography data of the skeletal system.

    Science.gov (United States)

    Troy, Karen L; Edwards, W Brent

    2018-05-01

    Quantitative CT (QCT) analysis involves the calculation of specific parameters such as bone volume and density from CT image data, and can be a powerful tool for understanding bone quality and quantity. However, without careful attention to detail during all steps of the acquisition and analysis process, data can be of poor- to unusable-quality. Good quality QCT for research requires meticulous attention to detail and standardization of all aspects of data collection and analysis to a degree that is uncommon in a clinical setting. Here, we review the literature to summarize practical and technical considerations for obtaining high quality QCT data, and provide examples of how each recommendation affects calculated variables. We also provide an overview of the QCT analysis technique to illustrate additional opportunities to improve data reproducibility and reliability. Key recommendations include: standardizing the scanner and data acquisition settings, minimizing image artifacts, selecting an appropriate reconstruction algorithm, and maximizing repeatability and objectivity during QCT analysis. The goal of the recommendations is to reduce potential sources of error throughout the analysis, from scan acquisition to the interpretation of results. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. 40 CFR Appendix I to Part 50 - Interpretation of the 8-Hour Primary and Secondary National Ambient Air Quality Standards for Ozone

    Science.gov (United States)

    2010-07-01

    ... Secondary National Ambient Air Quality Standards for Ozone 1. General. This appendix explains the data.... Primary and Secondary Ambient Air Quality Standards for Ozone. 2.1 Data Reporting and Handling Conventions... and Secondary National Ambient Air Quality Standards for Ozone I Appendix I to Part 50 Protection of...

  10. PIAAC Technical Standards and Guidelines

    Science.gov (United States)

    OECD Publishing, 2014

    2014-01-01

    The Programme for International Assessment of Adult Competencies (PIAAC) will establish technical standards and guidelines to ensure that the survey design and implementation processes of PIAAC yield high-quality and internationally comparable data. This document provides a revised version of the technical standards and guidelines originally…

  11. Project Quality Plan

    DEFF Research Database (Denmark)

    Sandborg-Petersen, Ulrik; Øhrstrøm, Peter

    This document defines the procedures, standards, and strategies which will be used to ensure high standards of quality of the work produced within the HANDS project. It contains the following sections...

  12. A direct sensitivity approach to predict hourly ozone resulting from compliance with the National Ambient Air Quality Standard.

    Science.gov (United States)

    Simon, Heather; Baker, Kirk R; Akhtar, Farhan; Napelenok, Sergey L; Possiel, Norm; Wells, Benjamin; Timin, Brian

    2013-03-05

    In setting primary ambient air quality standards, the EPA's responsibility under the law is to establish standards that protect public health. As part of the current review of the ozone National Ambient Air Quality Standard (NAAQS), the US EPA evaluated the health exposure and risks associated with ambient ozone pollution using a statistical approach to adjust recent air quality to simulate just meeting the current standard level, without specifying emission control strategies. One drawback of this purely statistical concentration rollback approach is that it does not take into account spatial and temporal heterogeneity of ozone response to emissions changes. The application of the higher-order decoupled direct method (HDDM) in the community multiscale air quality (CMAQ) model is discussed here to provide an example of a methodology that could incorporate this variability into the risk assessment analyses. Because this approach includes a full representation of the chemical production and physical transport of ozone in the atmosphere, it does not require assumed background concentrations, which have been applied to constrain estimates from past statistical techniques. The CMAQ-HDDM adjustment approach is extended to measured ozone concentrations by determining typical sensitivities at each monitor location and hour of the day based on a linear relationship between first-order sensitivities and hourly ozone values. This approach is demonstrated by modeling ozone responses for monitor locations in Detroit and Charlotte to domain-wide reductions in anthropogenic NOx and VOCs emissions. As seen in previous studies, ozone response calculated using HDDM compared well to brute-force emissions changes up to approximately a 50% reduction in emissions. A new stepwise approach is developed here to apply this method to emissions reductions beyond 50% allowing for the simulation of more stringent reductions in ozone concentrations. Compared to previous rollback methods, this

  13. Standard values of quality and ore mining costs in management of multi-plant mining company

    Energy Technology Data Exchange (ETDEWEB)

    Kudelko, Jan [KGHM CUPRUM Research and Development Center, Wroclaw (Poland); Wirth, Herbert [KGHM Polska Miedz S.A., Lubin (Poland)

    2010-03-15

    Profitability of copper deposit mining depends on three basic variables, electrolytic copper price, manufacturing and selling costs of copper and company property involved in production process. If the company property is adjusted to its tasks then the mining profiability depends on costs of copper mining and selling, because the price is the external variable defined by the market. We can shape the costs in two (complementary) ways, traditionally, reducing the labor, material and power consumption, and by adjusting the quality of mined ore (copper content) to the level required by the current copper prices. Required quality of copper ore in the whole company we determine according to the accepted profitability criteria and then we determine quality standard for individual mines. Algorithms determining the ore quality standard resulting from current market price of copper are presented in the paper. Calculation models for the mined ore quality standards, unit mining costs per one ton of copper, electrolytic copper production and ore output are given. Standards were established for one variable assuming that the other variables are determined in this calculation. Innovative solution, presented in the paper, is the method of decomposition of the company controllable variables into the tasks for individual mines providing reaching the targets to the whole technological circuit. Using the models, having relatively few data, it will be possible to calculate quickly the values which are interesting for managers such as for example the prognosis of rate of return (economic or operational), required copper content in the mined ore for the whole company and individual mines at given rate of return or boundary level of copper content in comparison with cost and production level. Examples of calculation are provided. (orig.)

  14. Use of MODIS Terra Imagery to Estimate Surface Water Quality Standards, Using Lake Thonotosassa, Florida, as a Case Study

    Science.gov (United States)

    Moreno, Max J.; Al-Hamdan, Mohammad Z.; Estes, Maurice G., Jr.; Rickman, Douglas L.

    2010-01-01

    Lake Thonotosassa is a highly eutrophied lake located in an area with rapidly growing population in the Tampa Bay watershed, Florida. The Florida Administrative Code has designated its use for "recreation, propagation and maintenance of a healthy, well-balanced population of fish and wildlife." Although this lake has been the subject of efforts to improve water quality since 1970, overall water quality has remained below the acceptable state standards, and has a high concentration of nutrients. This condition is of great concern to public health since it has favored episodic blooms of Cyanobacteria. Some Cyanobacterial species release toxins that can reach humans through drinking water, fish consumption, and direct contact with contaminated water. The lake has been historically popular for fishing and water sports, and its overflow water drains into the Hillsborough River, the main supply of municipal water for the City of Tampa, this explains why it has being constantly monitored in situ for water quality by the Environmental Protection Commission of Hillsborough County (EPC). Advances in remote sensing technology, however, open the possibility of facilitating similar types of monitoring in this and similar lakes, further contributing to the implementation of surveillance systems that would benefit not just public health, but also tourism and ecosystems. Although traditional application of this technology to water quality has been focused on much larger coastal water bodies like bays and estuaries, this study evaluates the feasibility of its application on a 46.6 km2 freshwater lake. Using surface reflectance products from Moderate-Resolution Imaging Spectroradiometer (MODIS) Terra, this study evaluates associations between remotely sensed data and in situ data from the EPC. The parameters analyzed are the surface water quality standards used by the State of Florida and general indicators of trophic status.

  15. Assessing the quality of decision support technologies using the International Patient Decision Aid Standards instrument (IPDASi.

    Directory of Open Access Journals (Sweden)

    Glyn Elwyn

    Full Text Available To describe the development, validation and inter-rater reliability of an instrument to measure the quality of patient decision support technologies (decision aids.Scale development study, involving construct, item and scale development, validation and reliability testing.There has been increasing use of decision support technologies--adjuncts to the discussions clinicians have with patients about difficult decisions. A global interest in developing these interventions exists among both for-profit and not-for-profit organisations. It is therefore essential to have internationally accepted standards to assess the quality of their development, process, content, potential bias and method of field testing and evaluation.Scale development study, involving construct, item and scale development, validation and reliability testing.Twenty-five researcher-members of the International Patient Decision Aid Standards Collaboration worked together to develop the instrument (IPDASi. In the fourth Stage (reliability study, eight raters assessed thirty randomly selected decision support technologies.IPDASi measures quality in 10 dimensions, using 47 items, and provides an overall quality score (scaled from 0 to 100 for each intervention. Overall IPDASi scores ranged from 33 to 82 across the decision support technologies sampled (n = 30, enabling discrimination. The inter-rater intraclass correlation for the overall quality score was 0.80. Correlations of dimension scores with the overall score were all positive (0.31 to 0.68. Cronbach's alpha values for the 8 raters ranged from 0.72 to 0.93. Cronbach's alphas based on the dimension means ranged from 0.50 to 0.81, indicating that the dimensions, although well correlated, measure different aspects of decision support technology quality. A short version (19 items was also developed that had very similar mean scores to IPDASi and high correlation between short score and overall score 0.87 (CI 0.79 to 0.92.This work

  16. The Quality of Teaching Staff: Higher Education Institutions' Compliance with the European Standards and Guidelines for Quality Assurance--The Case of Portugal

    Science.gov (United States)

    Cardoso, Sónia; Tavares, Orlanda; Sin, Cristina

    2015-01-01

    In recent years, initiatives for the improvement of teaching quality have been pursued both at European and national levels. Such is the case of the European Standards and Guidelines for Quality Assurance (ESG) and of legislation passed by several European countries, including Portugal, in response to European policy developments driven by the…

  17. Fabrication of high-quality brazed joints

    International Nuclear Information System (INIS)

    Orlov, A.V.

    1980-01-01

    Problem of ensuring of joint high-quality when brazing different parts in power engineering is considered. To obtain high-quality joints it is necessary to correctly design brazed joint and to choose a gap width, overlap length and fillet radius; to clean up carefully the surfaces to be brazed and fix them properly one relative to another; to apply a solder so as to provide its flowing into the gap and sticking in it; to exactly regulate thermal conditions of brazing. High quality and reliability of brazed joints are ensured by the application of solders based on noble metals, and cheap solders based on nickel, manganese and copper. Joints brazed with nickel base solders may operate at temperatures as high as 888 deg C

  18. Will the circle be unbroken: a history of the U.S. National Ambient Air Quality Standards.

    Science.gov (United States)

    Bachmann, John

    2007-06-01

    In celebration of the 100th anniversary of the Air & Waste Management Association, this review examines the history of air quality management (AQM) in the United States over the last century, with an emphasis on the ambient standards programs established by the landmark 1970 Clean Air Act (CAA) Amendments. The current CAA system is a hybrid of several distinct air pollution control philosophies, including the recursive or circular system driven by ambient standards. Although this evolving system has resulted in tremendous improvements in air quality, it has been far from perfect in terms of timeliness and effectiveness. The paper looks at several periods in the history of the U.S. program, including: (1) 1900-1970, spanning the early smoke abatement and smog control programs, the first federal involvement, and the development of a hybrid AQM approach in the 1970 CAA; (2) 1971-1976, when the first National Ambient Air Quality Standards (NAAQS) were set and implemented; (3) 1977-1993, a period of the first revisions to the standards, new CAA Amendments, delays in implementation and decision-making, and key science/policy/legislative developments that would alter both the focus and scale of air pollution programs and how they are implemented; and (4) 1993-2006, the second and third wave of NAAQS revisions and their implementation in the context of the 1990 CAA. This discussion examines where NAAQS have helped drive implementation programs and how improvements in both effects and air quality/control sciences influenced policy and legislation to enhance the effectiveness of the system over time. The review concludes with a look toward the future of AQM, emphasizing challenges and ways to meet them. The most significant of these is the need to make more efficient progress toward air quality goals, while adjusting the system to address the growing intersections between air quality management and climate change.

  19. 77 FR 74923 - Water Quality Standards for the State of Florida's Estuaries, Coastal Waters, and South Florida...

    Science.gov (United States)

    2012-12-18

    ... proposing numeric water quality criteria to protect ecological systems, aquatic life, and human health from... III surface waters share water quality criteria established to protect fish consumption, recreation... Water Quality Standards for the State of Florida's Estuaries, Coastal Waters, and South Florida Inland...

  20. Vocational High School Effectiveness Standard ISO 9001: 2008 for Achievement Content Standards, Standard Process and Competency Standards Graduates

    Directory of Open Access Journals (Sweden)

    Yeni Ratih Pratiwi

    2014-06-01

    Full Text Available Efektivitas Sekolah Menengah Kejuruan Berstandar ISO 9001:2008 terhadap Pencapaian Standar Isi, Standar Proses dan Standar Kompetensi Lulusan Abstract: The purpose of this study was to determine differences in the effectiveness of the achievement of the content standards, process standards, and competency standards in vocational already standard ISO 9001: 2008 with CMS that has not been standardized ISO 9001: 2008 both in public schools and private schools. Data collection using the questionnaire enclosed Likert scale models. Analysis of data using one-way ANOVA using SPSS. The results showed: (1 there is no difference in effectiveness between public SMK ISO standard ISO standards with private SMK (P = 0.001; (2 there are differences in the effectiveness of public SMK SMK ISO standards with ISO standards have not (P = 0.000; (3 there are differences in the effectiveness of public SMK ISO standards with private vocational yet ISO standards (P = 0.000; (4 there are differences in the effectiveness of the private vocational school with vocational standard ISO standard ISO country has not (P = 0.015; (5 there are differences in the effectiveness of the private vocational bertandar ISO with private vocational yet standardized ISO (P = 0.000; (6 there was no difference in the effectiveness of public SMK has not been standardized by the ISO standard ISO private SMK yet. Key Words: vocational high school standards ISO 9001: 2008, the standard content, process standards, competency standards Abstrak: Tujuan penelitian ini untuk mengetahui perbedaan efektivitas pencapaian standar isi, standar proses, dan standar kompetensi lulusan pada SMK yang sudah berstandar ISO 9001:2008 dengan SMK yang belum berstandar ISO 9001:2008 baik pada sekolah negeri maupun sekolah swasta. Pengumpulan data menggunakan kuisioner tertutup model skala likert. Analisis data menggunakan ANOVA one way menggunakan program SPSS. Hasil penelitian menunjukkan: (1 ada perbedaan

  1. Integration of Engineering Education by High School Teachers to Meet Standards in the Physics Classroom

    Science.gov (United States)

    Kersten, Jennifer Anna

    In recent years there has been increasing interest in engineering education at the K-12 level, which has resulted in states adopting engineering standards as a part of their academic science standards. From a national perspective, the basis for research into engineering education at the K-12 level is the belief that it is of benefit to student learning, including to "improve student learning and achievement in science and mathematics; increase awareness of engineering and the work of engineers; boost youth interest in pursuing engineering as a career; and increase the technological literacy of all students" (National Research Council, 2009a, p. 1). The above has led to a need to understand how teachers are currently implementing engineering education in their classrooms. High school physics teachers have a history of implementing engineering design projects in their classrooms, thus providing an appropriate setting to look for evidence of quality engineering education at the high school level. Understanding the characteristics of quality engineering integration can inform curricular and professional development efforts for teachers asked to implement engineering in their classrooms. Thus, the question that guided this study is: How, and to what extent, do physics teachers represent quality engineering in a physics unit focused on engineering? A case study research design was implemented for this project. Three high school physics teachers were participants in this study focused on the integration of engineering education into the physics classroom. The data collected included observations, interviews, and classroom documents that were analyzed using the Framework for Quality K-12 Engineering Education (Moore, Glancy et al., 2013). The results provided information about the areas of the K-12 engineering framework addressed during these engineering design projects, and detailed the quality of these lesson components. The results indicate that all of the design

  2. A potential gender bias in assessing quality of life - a standard gamble experiment among university students.

    Science.gov (United States)

    Obaidi, Leath Al; Mahlich, Jörg

    2015-01-01

    There are several methodologies that can be used for evaluating patients' perception of their quality of life. Most commonly, utilities are directly elicited by means of either the time-trade-off or the standard-gamble method. In both methods, risk attitudes determine the quality of life values. Quality of life values among 31 Austrian undergraduate students were elicited by means of the standard gamble approach. The impact of several variables such as gender, side job, length of study, and living arrangements on the quality of life were identified using different types of regression techniques (ordinary least squares, generalized linear model, Betafit). Significant evidence was found that females are associated with a higher quality of life in all specifications of our estimations. The observed gender differences in quality of life can be attributed to a higher degree of risk aversion of women. A higher risk aversion leads to a higher valuation of given health states and a potential gender bias in health economic evaluations. This result could have implications for health policy planners when it comes to budget allocation decisions.

  3. Preparation of high purity plutonium oxide for radiochemistry instrument calibration standards and working standards

    International Nuclear Information System (INIS)

    Wong, A.S.; Stalnaker, N.D.

    1997-04-01

    Due to the lack of suitable high level National Institute of Standards and Technology (NIST) traceable plutonium solution standards from the NIST or commercial vendors, the CST-8 Radiochemistry team at Los Alamos National Laboratory (LANL) has prepared instrument calibration standards and working standards from a well-characterized plutonium oxide. All the aliquoting steps were performed gravimetrically. When a 241 Am standardized solution obtained from a commercial vendor was compared to these calibration solutions, the results agreed to within 0.04% for the total alpha activity. The aliquots of the plutonium standard solutions and dilutions were sealed in glass ampules for long term storage

  4. Using National Ambient Air Quality Standards for fine particulate matter to assess regional wildland fire smoke and air quality management.

    Science.gov (United States)

    Schweizer, Don; Cisneros, Ricardo; Traina, Samuel; Ghezzehei, Teamrat A; Shaw, Glenn

    2017-10-01

    Wildland fire is an important ecological process in the California Sierra Nevada. Personal accounts from pre-20th century describe a much smokier environment than present day. The policy of suppression beginning in the early 20th century and climate change are contributing to increased megafires. We use a single particulate monitoring site at the wildland urban interface to explore impacts from prescribed, managed, and full suppression wildland fires from 2006 to 2015 producing a contextual assessment of smoke impacts over time at the landscape level. Prescribed fire had little effect on local fine particulate matter (PM 2.5 ) air quality with readings typical of similar non-fire times; hourly and daily good to moderate Air Quality Index (AQI) for PM 2.5 , maximum hourly concentrations 21-103 μg m -3 , and mean concentrations between 7.7 and 13.2 μg m -3 . Hourly and daily AQI was typically good or moderate during managed fires with 3 h and one day reaching unhealthy while the site remained below National Ambient Air Quality Standards (NAAQS), with maximum hourly concentrations 27-244 μg m -3 , and mean concentrations 6.7-11.7 μg m -3 . The large high intensity fire in this area created the highest short term impacts (AQI unhealthy for 4 h and very unhealthy for 1 h), 11 unhealthy for sensitive days, and produced the only annual value (43.9 μg m -3 ) over the NAAQS 98th percentile for PM 2.5 (35 μg m -3 ). Pinehurst remained below the federal standards for PM 2.5 when wildland fire in the local area was managed to 7800 ha (8-22% of the historic burn area). Considering air quality impacts from smoke using the NAAQS at a landscape level over time can give land and air managers a metric for broader evaluation of smoke impacts particularly when assessing ecologically beneficial fire. Allowing managers to control the amount and timing of individual wildland fire emissions can help lessen large smoke impacts to public health from a megafire

  5. Perceptions About The ISO 9000 Quality System Standard Revision And Its Value: The Dutch Experience

    NARCIS (Netherlands)

    A. van der Wiele (Ton); J.D. van Iwaarden (Jos); A.R.T. Williams (Roger); B.G. Dale (Barry)

    2004-01-01

    textabstractThe aim of the research reported in this paper is to assess the relative value of the 2000 version of the ISO 9000 series of quality management system standards in comparison to the 1994 version. 773 organisations in the Netherlands which have all been certified to the ISO 9000 standard

  6. THE EFFECT OF UNEQUAL DISTRIBUTION OF THE STANDARD AND QUALITY OF

    Directory of Open Access Journals (Sweden)

    JELENA TOSKOVIC

    2015-10-01

    Full Text Available In the early 1990s the Western Balkan countries entered the transition process which involved the transition from a centrally-planned to a market economy. Thus, these countries were forced to adhere to the basic neoliberal principles based on the Washington consensus, which has promoted the liberalization, privatization and stabilization. This model, in all transition countries, and thus the countries of the Western Balkans (Albania, Bosnia and Herzegovina, FYR Macedonia, Montenegro, Serbia, was governed by the same guidelines. However, the consequence occurred but economic and social crisis that led to decades of growth of economic inequality. Deformation of the unequal distribution led to the economic and social stratification which is disabled out of the economic crisis in which these countries found. In this paper we analyzed indicators Gini coefficient, the standard of living and quality of life that affect the life of the inhabitants of the Western Balkans. Gini coefficient as the most commonly used measure for measuring economic inequality, measured the distribution of income or consumption expenditure among households or individuals who within an economy deviates from the even distribution. The standard of living is determined by the totality of the conditions of life and work of the individual layers of the population of a country in a given time period.It is related to quality of life and is used for comparative reviews and comparisons of geographic areas, a number of vacation days, and then to compare different periods in history and more. Quality of life is intangible thesis, which includes the assessment of quality of life factors such as employment, income, health, education, science, energy, knowledge and technology, the environment, human rights, protection and recreation, infrastructure, national security, public safety, etc. All these factors combine to affect the life of the population, which from the beginning of the

  7. Perceptual video quality assessment in H.264 video coding standard using objective modeling.

    Science.gov (United States)

    Karthikeyan, Ramasamy; Sainarayanan, Gopalakrishnan; Deepa, Subramaniam Nachimuthu

    2014-01-01

    Since usage of digital video is wide spread nowadays, quality considerations have become essential, and industry demand for video quality measurement is rising. This proposal provides a method of perceptual quality assessment in H.264 standard encoder using objective modeling. For this purpose, quality impairments are calculated and a model is developed to compute the perceptual video quality metric based on no reference method. Because of the shuttle difference between the original video and the encoded video the quality of the encoded picture gets degraded, this quality difference is introduced by the encoding process like Intra and Inter prediction. The proposed model takes into account of the artifacts introduced by these spatial and temporal activities in the hybrid block based coding methods and an objective modeling of these artifacts into subjective quality estimation is proposed. The proposed model calculates the objective quality metric using subjective impairments; blockiness, blur and jerkiness compared to the existing bitrate only calculation defined in the ITU G 1070 model. The accuracy of the proposed perceptual video quality metrics is compared against popular full reference objective methods as defined by VQEG.

  8. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  9. Quality Assurance in Nuclear Fuel Research at the Laboratory of High- and Medium-level Activity at SCK-CEN

    Energy Technology Data Exchange (ETDEWEB)

    Sannen, L.; Gys, A.; Verwerft, M

    1999-10-01

    Quality assurance in nuclear fuel research demands specific calibration and validation methodologies. Indeed the analytical experiments in hot-cells on highly radioactive objects are non-standard and many times unique. The standards and validation methods developed for and applied to the main nuclear fuel research experiments in the hot laboratories of the Belgian Nuclear Research Centre SCK-CEN are outlined.

  10. Quality Assurance in Nuclear Fuel Research at the Laboratory of High- and Medium-level Activity at SCK-CEN

    International Nuclear Information System (INIS)

    Sannen, L.; Gys, A.; Verwerft, M.

    1999-10-01

    Quality assurance in nuclear fuel research demands specific calibration and validation methodologies. Indeed the analytical experiments in hot-cells on highly radioactive objects are non-standard and many times unique. The standards and validation methods developed for and applied to the main nuclear fuel research experiments in the hot laboratories of the Belgian Nuclear Research Centre SCK-CEN are outlined

  11. C++ Coding Standards 101 Rules, Guidelines, and Best Practices

    CERN Document Server

    Sutter, Herb

    2005-01-01

    Consistent, high-quality coding standards improve software quality, reduce time-to-market, promote teamwork, eliminate time wasted on inconsequential matters, and simplify maintenance. Now, two of the world's most respected C++ experts distill the rich collective experience of the global C++ community into a set of coding standards that every developer and development team can understand and use as a basis for their own coding standards.

  12. Development of quality standards of medicinal mistletoe – Helicanthes elastica (Desr. Danser employing Pharmacopoeial procedures

    Directory of Open Access Journals (Sweden)

    K.N. Sunil Kumar

    2016-11-01

    Full Text Available Helicanthes elastica (Desr. Danser (Loranthaceae, commonly known as Indian mango mistletoe, is a parasitic shrub found widely growing on mango trees in southern India. Development of monographic quality standards is need of the hour for Pharmacopoeial/extra-Pharmacopoeial and folk medicinal plants. Systematic pharmacognostical evaluation of leaves of H. elastica has been carried out employing Pharmacopoeial procedures of testing herbal drugs. Macro–microscopic features of H. elastica leaf were recorded. Ethanolic extract was tested positive for alkaloids, steroids, carbohydrates, tannins, saponins and phenols. HPTLC fingerprint profile was developed for the identification of extracts using reference standard β-sitosterol glucoside. Results of the present investigation would serve as a source of pharmacognostical information and a document to control the quality of H. elastica (Desr. Danser. Keywords: HPTLC, Mango mistletoe, Medicinal plant monograph, Quality control

  13. A Proposed Framework for Applying the National Standards of Quality Assurance in Higher Education in Sudan from the Teaching Staff’s Perspective - Faculties of Business Administration

    Directory of Open Access Journals (Sweden)

    Alfatih Alamin Elfaki

    2017-08-01

    Full Text Available This study aimed to clarify the importance of having national standards and their role in achieving quality, as well as establishing a framework for the actual application of national standards in quality assurance so as to achieve quality in higher education institutions. The researchers  followed a descriptive analytical method to achieve the objectives of the study and developed a questionnaire covering primary and secondary variables that have a role in the design of specific models to help in applying the national standards by the Sudanese universities. The questionnaire included one dependent variable; the effective application of national standards of quality assurance in higher education institutions, and the four main variables (independent are: the national standards of quality assurance in higher education in Sudan, the standard of quality assurance, the standard of teaching and learning and the standard of scientific research and publication. The study revealed a number of conclusions: there were statistically significant differences in the extent of familiarity with the  national quality assurance standards in Sudan according to the academic rank of the  faculty members; there were also significant differences in the extent of compliance with the  national quality assurance standards in Sudan according to the academic rank of the faculty members; there was full agreement between the national standards for quality assurance in Sudan and the international standards for quality assurance; and  there were statistically significant differences in that the absence of specific models would have a negative impact on effective application of national standards of quality assurance in higher education in Sudan, according to the academic rank of the faculty members. Keywords: Quality, The program, Standards, University, Total quality management.

  14. The critical role of nurses to the successful implementation of the National Safety and Quality Health Service Standards.

    Science.gov (United States)

    Twigg, Diane E; Duffield, Christine; Evans, Gemma

    2013-09-01

    The National Safety and Quality Health Service Standards requires health service compliance by 2013 and covers several areas including governance arrangements, partnerships with consumers and eight key clinical processes. Nurses in Australia comprise 62% of the hospital workforce, are the largest component and hence play a critical role in meeting these standards and improving the quality of patient care. Several of the standards are influenced by nursing interventions, which incorporate any direct-care treatment that the nurse performs for a patient that may be nurse or physician initiated. The ability for nurses to undertake these interventions is influenced by the hours of care available, the skill mix of the nursing workforce and the environment in which they practice. Taking into consideration the predicted nursing shortages, the challenge to successfully implement the National Safety and Quality Health Service Standards will be great. This paper examines the role of nursing in the delivery of the National Standards, analyses the evidence with regard to nursing-sensitive outcomes and discusses the implications for health service decision makers and policy.

  15. Small scale biomass heating systems: Standards, quality labelling and market driving factors - An EU outlook

    International Nuclear Information System (INIS)

    Verma, V.K.; De Ruyck, J.; Bram, S.

    2009-01-01

    In the present study a comparative evaluation of several existing quality labels and standards for small scale biomass heating systems (BHS) and the biomass fuels they use was performed. With the introduction of pellet fuels, biomass heating technology achieved enough maturity to successfully compete with oil/gas heating devices in terms of ease of use, utilization of energy and pollutant emissions. From indoor air quality and related health risks point of view, quality labelling of both BHS and fuel they use leads to stricter emissions, efficiency and safety requirements as compared to National and EU standards. Several measures supporting this green energy market in the active countries (Sweden, Nordic countries, Germany, France and Austria) were investigated. It was found that policies and financial incentives such as the Finance Law (2005-2009) in France and Market Incentives Programme (1999-2006) in Germany are the most successful. German regulations and quality label (Blue Angel) provide the stringent quality requirements for residential BHS. In Belgium, Wallonia is the most active region for biomass energy utilization (83.5 MW for residential heating in 2007). A quality label for small scale BHS however does not yet exist. An equivalent label (Optimaz) exists for oil fired residential boilers. Emphasis has been placed upon using Optimaz as a reference and to compare with other existing quality labels. As a result, an effort had been made to move ahead in the preliminary study for development of a quality label for Belgian. (author)

  16. A potential gender bias in assessing quality of life – a standard gamble experiment among university students

    Directory of Open Access Journals (Sweden)

    Al Obaidi L

    2015-04-01

    Full Text Available Leath Al Obaidi,1 Jörg Mahlich2,3 1University of Nottingham, School of Economics, Nottingham, UK; 2Health Economics, Janssen KK, Tokyo, Japan; 3Düsseldorf Institute for Competition Economics (DICE, University of Düsseldorf, Düsseldorf, Germany Background: There are several methodologies that can be used for evaluating patients' perception of their quality of life. Most commonly, utilities are directly elicited by means of either the time-trade-off or the standard-gamble method. In both methods, risk attitudes determine the quality of life values. Methods: Quality of life values among 31 Austrian undergraduate students were elicited by means of the standard gamble approach. The impact of several variables such as gender, side job, length of study, and living arrangements on the quality of life were identified using different types of regression techniques (ordinary least squares, generalized linear model, Betafit. Results: Significant evidence was found that females are associated with a higher quality of life in all specifications of our estimations. Discussion: The observed gender differences in quality of life can be attributed to a higher degree of risk aversion of women. A higher risk aversion leads to a higher valuation of given health states and a potential gender bias in health economic evaluations. This result could have implications for health policy planners when it comes to budget allocation decisions. Keywords: quality of life, gender, risk aversion, standard gamble, students 

  17. Availability of high quality weather data measurements

    DEFF Research Database (Denmark)

    Andersen, Elsa; Johansen, Jakob Berg; Furbo, Simon

    In the period 2016-2017 the project “Availability of high quality weather data measurements” is carried out at Department of Civil Engineering at the Technical University of Denmark. The aim of the project is to establish measured high quality weather data which will be easily available...... for the building energy branch and the solar energy branch in their efforts to achieve energy savings and for researchers and students carrying out projects where measured high quality weather data are needed....

  18. Application of principles of quality assurance recommended by ISO 9000 Standards to Regulatory Program

    International Nuclear Information System (INIS)

    Jova Sed, Luis Andres; Bilbao Alfonso, Alejandro Victor

    2001-01-01

    For several years, the necessity of applying the programs of quality assurance to the radiation protection activities has been highlighted; however there has been little progress in this direction, even in the philosophical and methodological development of the topic. The objective of this work is to transmit some recommendations of how the Regulatory Authorities of developing countries can organize the quality assurance system of their own activity, following the main precepts of the international standard series ISO 9000. In very tight synthesis it describes the importance that has the definition of a policy of quality for a Regulatory Authority, the quality objectives, the definition of the responsibilities and attributions in relation with quality assurance, and others elements of the ISO 9000, and how to apply it. (author)

  19. Performance study of the primary standard ionization chamber for deployment of the diagnostic radiology qualities

    International Nuclear Information System (INIS)

    Cardoso, Ricardo de Souza; Bossio, Francisco; Quaresma, Daniel da Silva; Peixoto, Jose Guilherme Pereira

    2013-01-01

    Activities radiotherapy, diagnostic radiology and radiation protection, require knowledge of physical and dosimetric parameters, to be applied safely. Aiming to meet demand in Brazil, the National Laboratory of Metrology of Ionising Radiation - LNMRI - is deploying the primary standard for the calibration of secondary standard chambers, used in quality control in hospitals, clinics and industries. (author)

  20. A Study on Financial Reporting Standards and Accounting Quality- Evidence from China

    Science.gov (United States)

    Liou, Cheng-Hwai

    2013-02-01

    According to institutional theorists, the forms and business models of corporation are mainly shaped by factors such as politics, regulations, social norms and cultures. This paper examines how the International Financial Reporting Standards (IFRS) and institutional environment influence the accounting quality, in response to the threat of political extraction in China. We took mainland China as an example instead in our study, following the accounting quality definition of Barth et al. [2], we found that the developments of Chinese government performance audit are conspicuously different by region; to reflect such differences, we elaborated our research by dividing mainland China into 31 categories (provinces or cities). We set 2003-2010 as the time horizon for this study. After testing the Regression model, our empirical research achieved two conclusions: 1) IFRS adoption in China should significantly improve the accounting quality, and 2) IFRS and institutional environment should synthetically influence the quality of accounting as well.

  1. Soil quality standards and guidelines for forest sustainability in northwestern North America

    Science.gov (United States)

    Deborah Page-Dumroese; Martin Jurgensen; William Elliot; Thomas Rice; John Nesser; Thomas Collins; Robert. Meurisse

    2000-01-01

    Soil quality standards and guidelines of the USDA Forest Service were some of the first in the world to be developed to evaluate changes in forest soil productivity and sustainability after harvesting and site preparation. International and national development of criteria and indicators for maintenance of soil productivity make it imperative to have adequate threshold...

  2. Relating road salt to exceedances of the water quality standard for chloride in New Hampshire streams.

    Science.gov (United States)

    Trowbridge, Philip R; Kahl, J Steve; Sassan, Dari A; Heath, Douglas L; Walsh, Edward M

    2010-07-01

    Six watersheds in New Hampshire were studied to determine the effects of road salt on stream water quality. Specific conductance in streams was monitored every 15 min for one year using dataloggers. Chloride concentrations were calculated from specific conductance using empirical relationships. Stream chloride concentrations were directly correlated with development in the watersheds and were inversely related to streamflow. Exceedances of the EPA water quality standard for chloride were detected in the four watersheds with the most development. The number of exceedances during a year was linearly related to the annual average concentration of chloride. Exceedances of the water quality standard were not predicted for streams with annual average concentrations less than 102 mg L(-1). Chloride was imported into three of the watersheds at rates ranging from 45 to 98 Mg Cl km(-2) yr(-1). Ninety-one percent of the chloride imported was road salt for deicing roadways and parking lots. A simple, mass balance equation was shown to predict annual average chloride concentrations from streamflow and chloride import rates to the watershed. This equation, combined with the apparent threshold for exceedances of the water quality standard, can be used for screening-level TMDLs for road salt in impaired watersheds.

  3. An investigation on comprehensive evaluation and standard of image quality of high voltage chest radiograph

    International Nuclear Information System (INIS)

    Yan Shulin; Li Shuopeng; Zhao Bo; Niu Yantao

    1998-01-01

    Purpose: Based on clinical diagnostic demand, patient irradiation dose and imaging technical parameters, to establish a comprehensive evaluation method and standard in chest radiograph. Methods: (1) From 10 normal chest radiographs, the authors selected the evaluation area on thoracic PA (posteroanterior) radiographs and set up standard for diagnostic demand; (2) Using chest CT scans of 20 males and 20 females, the authors calculated the ratio of lung field to mediastinum; (3) Selecting 100 chest films using 125 kVp, the authors measured the standard density values of each evaluation area; (4) Body surface irradiation doses of 478 normal adults were measured. Results: (1) Based on diagnostic demand, the authors confirmed 7 evaluation areas and 4 physical evaluation factors. At the same time, evaluation standards were obtained; (2) Comprehensive evaluation methods were established; (3) Standard height, weight and body surface irradiation dose of Chinese normal adults were investigated preliminarily. Conclusion: Based on the concept of comprehensive evaluation, investigation on the evaluation methods and standard in chest PA radiograph was carried out which might be taken as the foundation for future approach on nation-wide basis

  4. Seminar on standards, standardization, quality control and interlaboratory test programmes

    Energy Technology Data Exchange (ETDEWEB)

    de Bievre, P. [Central Bureau for Nuclear Measurements, Geel (Belgium)

    1978-12-15

    The author gives a resume on the proper use of standards and standardization of measurement procedures. Results of measurements obtained on the same instrument and on the same series of standards of different isotopic compositions are displayed.

  5. Living up to high standards and psychological distress

    NARCIS (Netherlands)

    Van Yperen, N.W.; Hagedoorn, Mariët

    We argue and demonstrate that setting high standards, an essential aspect of perfectionism, is not associated with maladaptive responses in and of itself. Rather, our findings suggest that people's responses to their perceptions that they consistently fail to meet their own standards are

  6. Importance of the Primary Radioactivity Standard Laboratory and Implementation of its Quality Management

    Science.gov (United States)

    Sahagia, Maria; Razdolescu, Anamaria Cristina; Luca, Aurelian; Ivan, Constantin

    2007-04-01

    The paper presents some specific aspects of the implementation of the quality management in the Radionuclide Metrology Laboratory, from IFIN-HH, the owner of the primary Romanian standard in radioactivity. The description of the accreditation, according to the EN ISO/IEC 17025:2005, is presented.

  7. Importance of the Primary Radioactivity Standard Laboratory and Implementation of its Quality Management

    International Nuclear Information System (INIS)

    Sahagia, Maria; Razdolescu, Anamaria Cristina; Luca, Aurelian; Ivan, Constantin

    2007-01-01

    The paper presents some specific aspects of the implementation of the quality management in the Radionuclide Metrology Laboratory, from IFIN-HH, the owner of the primary Romanian standard in radioactivity. The description of the accreditation, according to the EN ISO/IEC 17025:2005, is presented

  8. Raising the Bar on Faculty Productivity: Realigning Performance Standards to Enhance Quality Trajectories

    Science.gov (United States)

    Hardré, Patricia L.

    2014-01-01

    Many universities have observed needs and shared goals that include increasing faculty members' research productivity (in quantity or quality). Strategies for raising faculty performance include revising standards and supporting valued outcomes with rewards and incentives. One college at a research-extensive university received institutional…

  9. Instrumentation Standard Architectures for Future High Availability Control Systems

    International Nuclear Information System (INIS)

    Larsen, R.S.

    2005-01-01

    Architectures for next-generation modular instrumentation standards should aim to meet a requirement of High Availability, or robustness against system failure. This is particularly important for experiments both large and small mounted on production accelerators and light sources. New standards should be based on architectures that (1) are modular in both hardware and software for ease in repair and upgrade; (2) include inherent redundancy at internal module, module assembly and system levels; (3) include modern high speed serial inter-module communications with robust noise-immune protocols; and (4) include highly intelligent diagnostics and board-management subsystems that can predict impending failure and invoke evasive strategies. The simple design principles lead to fail-soft systems that can be applied to any type of electronics system, from modular instruments to large power supplies to pulsed power modulators to entire accelerator systems. The existing standards in use are briefly reviewed and compared against a new commercial standard which suggests a powerful model for future laboratory standard developments. The past successes of undertaking such projects through inter-laboratory engineering-physics collaborations will be briefly summarized

  10. Highly qualified does not equal high quality: A study of urban stakeholders' perceptions of quality in science teaching

    Science.gov (United States)

    Miranda, Rommel Joseph

    By employing qualitative methods, this study sought to determine the perceptions that urban stakeholders hold about what characteristics should distinguish a high school science teacher whom they would consider to demonstrate high quality in science teaching. A maximum variation sample of six science teachers, three school administrators, six parents and six students from a large urban public school district were interviewed using semi-structured, in-depth interview techniques. From these data, a list of observable characteristics which urban stakeholders hold as evidence of high quality in science teaching was generated. Observational techniques were utilized to determine the extent to which six urban high school science teachers, who meet the NCLB Act criteria for being "highly qualified", actually possessed the characteristics which these stakeholders hold as evidence of high quality in science teaching. Constant comparative analysis was used to analyze the data set. The findings suggest that urban stakeholders perceive that a high school science teacher who demonstrates high quality in science teaching should be knowledgeable about their subject matter, their student population, and should be resourceful; should possess an academic background in science and professional experience in science teaching; should exhibit professionalism, a passion for science and teaching, and a dedication to teaching and student learning; should be skillful in planning and preparing science lessons and in organizing the classroom, in presenting the subject matter to students, in conducting a variety of hands-on activities, and in managing a classroom; and should assess whether students complete class goals and objectives, and provide feedback about grades for students promptly. The findings further reveal that some of the urban high school science teachers who were deemed to be "highly qualified", as defined by the NCLB Act, engaged in practices that threatened quality in science

  11. Leveraging Standards to Promote Program Quality

    Science.gov (United States)

    Young, Michelle D.; Mawhinney, Hanna; Reed, Cynthia J.

    2016-01-01

    Standards provide a foundation for thinking about leadership development and practice. This article explores three sets of standards that impact educational leadership preparation: (a) the recently revised Interstate School Leaders Licensure Consortium (ISLLC) standards, which are now known as the Practice Standards for Educational Leaders (PSEL);…

  12. Fast High-Quality Noise

    DEFF Research Database (Denmark)

    Frisvad, Jeppe Revall; Wyvill, Geoff

    2007-01-01

    At the moment the noise functions available in a graphics programmer's toolbox are either slow to compute or they involve grid-line artifacts making them of lower quality. In this paper we present a real-time noise computation with no grid-line artifacts or other regularity problems. In other words......, we put a new tool in the box that computes fast high-quality noise. In addition to being free of artifacts, the noise we present does not rely on tabulated data (everything is computed on the fly) and it is easy to adjust quality vs. quantity for the noise. The noise is based on point rendering (like...... spot noise), but it extends to more than two dimensions. The fact that it is based on point rendering makes art direction of the noise much easier....

  13. Functions of standard CPR training on performance qualities of medical volunteers for Mt. Taishan International Mounting Festival.

    Science.gov (United States)

    Fanshan, Meng; Lin, Zhao; Wenqing, Liu; Chunlei, Lu; Yongqiang, Liu; Naiyi, Li

    2013-01-01

    Cardiopulmonary resuscitation (CPR) is a sudden emergency procedure that requires a rapid and efficient response, and personnel training in lifesaving procedures. Regular practice and training are necessary to improve resuscitation skills and reduce anxiety among the staff. As one of the most important skills mastered by medical volunteers serving for Mt. Taishan International Mounting Festival, we randomly selected some of them to evaluate the quality of CPR operation and compared the result with that of the untrained doctors and nurses. In order to evaluate the functions of repeating standard CPR training on performance qualities of medical volunteers for Mt. Taishan International Mounting Festival, their performance qualities of CPR were compared with those of the untrained medical workers working in emergency departments of hospitals in Taian. The CPR performance qualities of 52 medical volunteers (Standard Training Group), who had continually taken part in standard CPR technical training for six months, were tested at random and were compared with those of 68 medical workers (Compared Group) working in emergency departments of hospitals in Taian who hadn't attended CPR training within a year. The QCPR 3535 monitor (provided by Philips Company) was used to measure the standard degree of single simulated CPR performance, including the chest compression depth, frequency, released pressure between compressions and performance time of compression and ventilation, the results of which were recorded in the table and the number of practical compression per minute was calculated. The data were analyzed by x2 Test and t Test. The factors which would influence CPR performance, including gender, age, placement, hand skill, posture of compression and frequency of training, were classified and given parameters, and were put to Logistic repression analysis. The CPR performance qualities of volunteers were much higher than those of the compared group. The overall pass rates

  14. Assuring quality in high-consequence engineering

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Marcey L.; Kolb, Rachel R.

    2014-03-01

    In high-consequence engineering organizations, such as Sandia, quality assurance may be heavily dependent on staff competency. Competency-dependent quality assurance models are at risk when the environment changes, as it has with increasing attrition rates, budget and schedule cuts, and competing program priorities. Risks in Sandia's competency-dependent culture can be mitigated through changes to hiring, training, and customer engagement approaches to manage people, partners, and products. Sandia's technical quality engineering organization has been able to mitigate corporate-level risks by driving changes that benefit all departments, and in doing so has assured Sandia's commitment to excellence in high-consequence engineering and national service.

  15. Determination of water environment standards based on water quality criteria in China: Limitations and feasibilities.

    Science.gov (United States)

    Wang, Tieyu; Zhou, Yunqiao; Bi, Cencen; Lu, Yonglong; He, Guizhen; Giesy, John P

    2017-07-01

    There is a need to formulate water environment standards (WESs) from the current water quality criteria (WQC) in China. To this end, we briefly summarize typical mechanisms applied in several countries with longer histories of developing WESs, and three limitations to formulating WESs in China were identified. After analyzing the feasibility factors including economic development, scientific support capability and environmental policies, we realized that China is still not ready for a complete change from its current nation-wide unified WES system to a local-standard-based system. Thus, we proposed a framework for transformation from WQC to WESs in China. The framework consists of three parts, including responsibilities, processes and policies. The responsibilities include research authorization, development of guidelines, and collection of information, at both national and local levels; the processes include four steps and an impact factor system to establish water quality standards; and the policies include seven specific proposals. Copyright © 2016. Published by Elsevier B.V.

  16. Section for Standard and Patents - Standardization and Patents

    International Nuclear Information System (INIS)

    Wojtowicz, S.; Trechcinski, R.; Rybka, M.; Ryszkowska, A.; Wardaszko, J.

    1997-01-01

    Full text: The most important tasks of the Section in 1996 were: preparation of national standards and program of future work on standards for nuclear instrumentation and electronic equipment in nuclear engineering; organization of activities and participation in the meetings of the Commissions for Standardization No 173 Microprocessor Systems, No 266 Nuclear Instrumentation; giving opinions and expertises on national and international standards for equipment in nuclear engineering; cooperation with the Commission for Standardization No 246 Radiological Protection; control of inventiveness activity; The quality of the technical products is being improved by: a) selection of the proper types of interface systems, technical coordination and quality control; b) creation of standards at a high technical level; The Section works mainly for the Polish Committee for Standardization, the National Atomic Energy Agency, Association of Polish Electrical Engineers and Research Institutes in Poland. The activity of the Section is useful for all national institutions where backplane busses and nuclear electronic equipment is produced or used. The Section participates in the following international organizations: IEC (International Electrotechnical Commission) TC 45 (Nuclear Instrumentation); ISO/IEC Joint Technical Committee ISO/IEC JTCl SC26 (Microprocessor systems); ESONE (European Studies on Norms for Electronics); The section takes part in popularization of nuclear technology and instrumentation in the following ways: distribution of standards and technical documentation to national institutions dealing with nuclear apparatus; collecting and distributing technical information from international organizations (e.g. ESONE); organization of technical and scientific, national and international conferences (New Generation Nuclear Power Plants - September 96, QNX in Real World - January 96); participation in the technical conference organized by the Polish Committee for

  17. H{sub 2}O{sub 2}-molecular beam epitaxy of high quality ZnO

    Energy Technology Data Exchange (ETDEWEB)

    El Shaer, A.; Bakin, A.; Che Mofor, A.; Kreye, M.; Waag, A. [Technical University Braunschweig, Institute of Semiconductor Technology, Braunschweig (Germany); Blaesing, J.; Krost, A. [Otto-von-Guericke-University, Institute of Experimental Physics, Magdeburg (Germany); Stoimenos, J. [Aristotele University, Physics Department, Thessaloniki (Greece); Pecz, B. [Hungarian Academy of Sciences, Research Institute for Technical Physics and Materials Science, P.O. Box 49, Budapest (Hungary)

    2007-07-15

    We have studied the growth and characterization of ZnO epilayers on (0001)-sapphire by H{sub 2}O{sub 2}-molecular beam epitaxy (MBE). A high temperature (HT) MgO buffer followed by a low-temperature ZnO buffer was introduced in order to accommodate the lattice mismatch between ZnO and sapphire. The surface morphology of the samples was studied using atomic force microscopy (AFM), and scanning electron microscopy (SEM). The crystalline quality of the layers was investigated by employing high resolution X-ray diffractometry (HRXRD) and high resolution transmission electron microscopy (HRTEM). The electrical properties of the grown ZnO layers were studied by Hall-effect measurements in a standard van der Pauw configuration. The measured surface roughness for the best layers is as low as 0.26 nm rms. HRXRD measurements of the obtained ZnO layers show excellent quality of the single crystalline ZnO heteroepitaxially grown on (0001)-sapphire with a HT MgO buffer layers. The influence of the growth conditions on the crystalline quality is discussed. The FWHM of the HRXRD (0002) rocking curves measured for the 2-inch ZnO-on-sapphire is as low as 27 arcsec with a very high lateral homogeneity across the whole 2-inch ZnO epilayers. The results indicate that H{sub 2}O{sub 2}-MBE is a suitable technique to fabricate ZnO epilayers of very high quality. (orig.)

  18. A high throughput DNA extraction method with high yield and quality

    Directory of Open Access Journals (Sweden)

    Xin Zhanguo

    2012-07-01

    Full Text Available Abstract Background Preparation of large quantity and high quality genomic DNA from a large number of plant samples is a major bottleneck for most genetic and genomic analyses, such as, genetic mapping, TILLING (Targeting Induced Local Lesion IN Genome, and next-generation sequencing directly from sheared genomic DNA. A variety of DNA preparation methods and commercial kits are available. However, they are either low throughput, low yield, or costly. Here, we describe a method for high throughput genomic DNA isolation from sorghum [Sorghum bicolor (L. Moench] leaves and dry seeds with high yield, high quality, and affordable cost. Results We developed a high throughput DNA isolation method by combining a high yield CTAB extraction method with an improved cleanup procedure based on MagAttract kit. The method yielded large quantity and high quality DNA from both lyophilized sorghum leaves and dry seeds. The DNA yield was improved by nearly 30 fold with 4 times less consumption of MagAttract beads. The method can also be used in other plant species, including cotton leaves and pine needles. Conclusion A high throughput system for DNA extraction from sorghum leaves and seeds was developed and validated. The main advantages of the method are low cost, high yield, high quality, and high throughput. One person can process two 96-well plates in a working day at a cost of $0.10 per sample of magnetic beads plus other consumables that other methods will also need.

  19. A high-throughput system for high-quality tomographic reconstruction of large datasets at Diamond Light Source.

    Science.gov (United States)

    Atwood, Robert C; Bodey, Andrew J; Price, Stephen W T; Basham, Mark; Drakopoulos, Michael

    2015-06-13

    Tomographic datasets collected at synchrotrons are becoming very large and complex, and, therefore, need to be managed efficiently. Raw images may have high pixel counts, and each pixel can be multidimensional and associated with additional data such as those derived from spectroscopy. In time-resolved studies, hundreds of tomographic datasets can be collected in sequence, yielding terabytes of data. Users of tomographic beamlines are drawn from various scientific disciplines, and many are keen to use tomographic reconstruction software that does not require a deep understanding of reconstruction principles. We have developed Savu, a reconstruction pipeline that enables users to rapidly reconstruct data to consistently create high-quality results. Savu is designed to work in an 'orthogonal' fashion, meaning that data can be converted between projection and sinogram space throughout the processing workflow as required. The Savu pipeline is modular and allows processing strategies to be optimized for users' purposes. In addition to the reconstruction algorithms themselves, it can include modules for identification of experimental problems, artefact correction, general image processing and data quality assessment. Savu is open source, open licensed and 'facility-independent': it can run on standard cluster infrastructure at any institution.

  20. Concrete Waste Recycling Process for High Quality Aggregate

    International Nuclear Information System (INIS)

    Ishikura, Takeshi; Fujii, Shin-ichi

    2008-01-01

    Large amount of concrete waste generates during nuclear power plant (NPP) dismantling. Non-contaminated concrete waste is assumed to be disposed in a landfill site, but that will not be the solution especially in the future, because of decreasing tendency of the site availability and natural resources. Concerning concrete recycling, demand for roadbeds and backfill tends to be less than the amount of dismantled concrete generated in a single rural site, and conventional recycled aggregate is limited of its use to non-structural concrete, because of its inferior quality to ordinary natural aggregate. Therefore, it is vital to develop high quality recycled aggregate for general uses of dismantled concrete. If recycled aggregate is available for high structural concrete, the dismantling concrete is recyclable as aggregate for industry including nuclear field. Authors developed techniques on high quality aggregate reclamation for large amount of concrete generated during NPP decommissioning. Concrete of NPP buildings has good features for recycling aggregate; large quantity of high quality aggregate from same origin, record keeping of the aggregate origin, and little impurities in dismantled concrete such as wood and plastics. The target of recycled aggregate in this development is to meet the quality criteria for NPP concrete as prescribed in JASS 5N 'Specification for Nuclear Power Facility Reinforced Concrete' and JASS 5 'Specification for Reinforced Concrete Work'. The target of recycled aggregate concrete is to be comparable performance with ordinary aggregate concrete. The high quality recycled aggregate production techniques are assumed to apply for recycling for large amount of non-contaminated concrete. These techniques can also be applied for slightly contaminated concrete dismantled from radiological control area (RCA), together with free release survey. In conclusion: a technology on dismantled concrete recycling for high quality aggregate was developed

  1. Standard review plan for the review of environmental restoration remedial action quality assurance program plans

    International Nuclear Information System (INIS)

    1991-09-01

    This plan establishes both the scope of the review and the acceptance criteria to be utilized for the review of Quality Assurance Program Plans (QAPPs) developed in accordance with the requirements of DOE/RL-90-28. DOE/RL-90-28, the Environmental Restoration Remedial Action Quality Assurance Requirements Document (QARD) defines all quality assurance (QA) requirements governing activities that affect the quality of the Environmental Restoration Remedial Action (ERRA) program at the Hanford Site. These requirements are defined in three parts, Part 1 of Quality Management and Administration tasks, Part 2 for Environmental Data Operations, and Part 3 of the Design and Construction of items, systems, and facilities. The purpose of this document is to identify the scope of the review by the DOE Field Office, Richland staff, and establish the acceptance criteria (Parts 1, 2, and 3) that the DOE Field Office, Richland staff will utilize to evaluate the participant QAPPs. Use of the standard review plan will (1) help ensure that participant QAPPs contain the information required by DOE/RL-90-28, (2) aid program participant and DOE Field Office, Richland staff is ensuring that the information describing the participant's QAPP is complete, (3) help persons regarding DOE/RL- 90-28 to locate information, and (4) contribute to decreasing the time needed for the review process. In addition, the Standard Review Plan (SRP) ensures the quality and uniformity of the staff reviews and presents a well-defined base from which to evaluate compliance of participant quality programs against DOE/RL-90-28

  2. National Standards for High School Psychology Curricula

    Science.gov (United States)

    American Psychologist, 2013

    2013-01-01

    The "National Standards for High School Psychology Curricula" attempts to represent current knowledge in the field of psychology in developmentally appropriate ways. Psychology is a popular high school course, one that can introduce students to scientific ideas and engage students in the learning process. However, it is difficult for even the best…

  3. Assessing the service quality of Iran military hospitals: Joint Commission International standards and Analytic Hierarchy Process (AHP) technique

    Science.gov (United States)

    Bahadori, Mohammadkarim; Ravangard, Ramin; Yaghoubi, Maryam; Alimohammadzadeh, Khalil

    2014-01-01

    Background: Military hospitals are responsible for preserving, restoring and improving the health of not only armed forces, but also other people. According to the military organizations strategy, which is being a leader and pioneer in all areas, providing quality health services is one of the main goals of the military health care organizations. This study was aimed to evaluate the service quality of selected military hospitals in Iran based on the Joint Commission International (JCI) standards and comparing these hospitals with each other and ranking them using the analytic hierarchy process (AHP) technique in 2013. Materials and Methods: This was a cross-sectional and descriptive study conducted on five military hospitals, selected using the purposive sampling method, in 2013. Required data collected using checklists of accreditation standards and nominal group technique. AHP technique was used for prioritizing. Furthermore, Expert Choice 11.0 was used to analyze the collected data. Results: Among JCI standards, the standards of access to care and continuity of care (weight = 0.122), quality improvement and patient safety (weight = 0.121) and leadership and management (weight = 0.117) had the greatest importance, respectively. Furthermore, in the overall ranking, BGT (weight = 0.369), IHM (0.238), SAU (0.202), IHK (weight = 0.125) and SAB (weight = 0.066) ranked first to fifth, respectively. Conclusion: AHP is an appropriate technique for measuring the overall performance of hospitals and their quality of services. It is a holistic approach that takes all hospital processes into consideration. The results of the present study can be used to improve hospitals performance through identifying areas, which are in need of focus for quality improvement and selecting strategies to improve service quality. PMID:25250364

  4. Assessing the service quality of Iran military hospitals: Joint Commission International standards and Analytic Hierarchy Process (AHP) technique.

    Science.gov (United States)

    Bahadori, Mohammadkarim; Ravangard, Ramin; Yaghoubi, Maryam; Alimohammadzadeh, Khalil

    2014-01-01

    Military hospitals are responsible for preserving, restoring and improving the health of not only armed forces, but also other people. According to the military organizations strategy, which is being a leader and pioneer in all areas, providing quality health services is one of the main goals of the military health care organizations. This study was aimed to evaluate the service quality of selected military hospitals in Iran based on the Joint Commission International (JCI) standards and comparing these hospitals with each other and ranking them using the analytic hierarchy process (AHP) technique in 2013. This was a cross-sectional and descriptive study conducted on five military hospitals, selected using the purposive sampling method, in 2013. Required data collected using checklists of accreditation standards and nominal group technique. AHP technique was used for prioritizing. Furthermore, Expert Choice 11.0 was used to analyze the collected data. Among JCI standards, the standards of access to care and continuity of care (weight = 0.122), quality improvement and patient safety (weight = 0.121) and leadership and management (weight = 0.117) had the greatest importance, respectively. Furthermore, in the overall ranking, BGT (weight = 0.369), IHM (0.238), SAU (0.202), IHK (weight = 0.125) and SAB (weight = 0.066) ranked first to fifth, respectively. AHP is an appropriate technique for measuring the overall performance of hospitals and their quality of services. It is a holistic approach that takes all hospital processes into consideration. The results of the present study can be used to improve hospitals performance through identifying areas, which are in need of focus for quality improvement and selecting strategies to improve service quality.

  5. [Quality assurance and quality management in intensive care].

    Science.gov (United States)

    Notz, K; Dubb, R; Kaltwasser, A; Hermes, C; Pfeffer, S

    2015-11-01

    Treatment success in hospitals, particularly in intensive care units, is directly tied to quality of structure, process, and outcomes. Technological and medical advancements lead to ever more complex treatment situations with highly specialized tasks in intensive care nursing. Quality criteria that can be used to describe and correctly measure those highly complex multiprofessional situations have only been recently developed and put into practice.In this article, it will be shown how quality in multiprofessional teams can be definded and assessed in daily clinical practice. Core aspects are the choice of a nursing theory, quality assurance measures, and quality management. One possible option of quality assurance is the use of standard operating procedures (SOPs). Quality can ultimately only be achieved if professional groups think beyond their boundaries, minimize errors, and establish and live out instructions and SOPs.

  6. Opinions on Fresh Produce Food Safety and Quality Standards by Fresh Produce Supply Chain Experts from the Global South and North.

    Science.gov (United States)

    Jacxsens, Liesbeth; Van Boxstael, Sigrid; Nanyunja, Jessica; Jordaan, Danie; Luning, Pieternel; Uyttendaele, Mieke

    2015-10-01

    This study describes the results of an on-line survey of fresh produce supply chain experts who work with producers from the Global North (n = 41, 20 countries) and the Global South (n = 63, 29 countries). They expressed their opinion using 1 to 5 Likert scales on several items related to four types of food safety and quality standards and legislation: Codex Alimentarius standards, European Union legislation, national legislation, and private standards. The results reflect the different circumstances under which the Southern and Northern producers operate in relation to the local organization, regulation, and support of the sector; but they also indicate similar challenges, in particular, the challenge of private standards, which were perceived to demand a higher implementation effort than the other three types of standards. Private standards were also strongly perceived to exclude Southern and Northern small- and medium-scale producers from high-value markets, whereas European Union legislation was perceived to strongly exclude, in particular, small- and medium-scale Southern producers. The results further highlight concerns about costly control measures and third-party certification that are required by downstream buyers but that are mostly paid for by upstream suppliers. Food standards are seen in their dual role as a catalyst for implementation of structured food safety management systems on the one hand and as a nontariff barrier to trade on the other hand. The results of the survey also pointed up the advantages of enforcing food safety and food quality standards in terms of knowledge spillover to noncertified activities, increased revenues, and improved food safety of delivered produce. Survey results highlight the importance of technical assistance and support of producers by governments and producer cooperatives or trade associations in the implementation and certification of food standards, along with increased awareness of and training of individuals in

  7. The need for a quality standard for assurance in medical research laboratories

    Directory of Open Access Journals (Sweden)

    S Cohen

    2014-01-01

    Full Text Available The objective of this article is to show the results of a research study conducted to evaluate the need for a quality standard specific for medical research laboratories based on the shortfalls of ISO 15189 when used for this purpose. A qualitative research methodology was used, which comprised of collecting data from 20 well-qualified and experienced medical laboratory personnel by means of interviews based on a framework developed from a literature review. The data were analysed by means of a thematic technique and the results were verified by a team of medical researchers. The seven themes arising from the analyses were inflexibility; ambiguity; unfair requirements; inappropriate focus; inadequacy for research; renewal; and acceptance for accreditation. The results indicated that the ISO 15189 standard in its present content does not totally suit medical research laboratories and shows support for the development of a standard specific for research laboratories.

  8. Standards, calibration and quality assurance of 222Rn measurements in Sweden

    International Nuclear Information System (INIS)

    Falk, R.; Hagberg, N.; Mjoenes, L.; Moere, H.; Nyblom, L.; Swedjemark, G.A.

    1994-01-01

    Inhaled decay products of 222 Rn are the dominant components of the natural radiation exposure to the general population. Limits have been introduced in Sweden, and recommendations were made in 1980 for decreasing indoor 222 Rn concentration. The need for the coordinated calibration of measuring instruments as well as for quality assurance was obvious for both health and economic reasons. 222 Rn measurements in Sweden are based on standards traceable to the National Institute of Standard and Technology (NIST) through the use of standard reference material 226 Ra. Standards for both 222 Rn and short-lived 222 Rn progeny are described together with the reference instrument adopted for these studies. The calibration of field instruments was performed in a ''radon room'', a climate chamber in which it is possible to vary and monitor the concentration of 222 Rn as well as other characteristics of the indoor air such as temperature, humidity, ventilation rate and aerosol concentration. The rules and regulations for field measurements imply a calibration of the instruments yearly, as well as accreditation and training for the companies that carry out the measurements. Examples are given of the official measurement protocols used for the different types of instruments. (orig.)

  9. Classification and Quality Standards of Heart Failure Units: Scientific Consensus of the Spanish Society of Cardiology.

    Science.gov (United States)

    Anguita Sánchez, Manuel; Lambert Rodríguez, José Luis; Bover Freire, Ramón; Comín Colet, Josep; Crespo Leiro, María G; González Vílchez, Francisco; Manito Lorite, Nicolás; Segovia Cubero, Javier; Ruiz Mateas, Francisco; Elola Somoza, Francisco Javier; Íñiguez Romo, Andrés

    2016-10-01

    The prevalence of heart failure remains high and represents the highest disease burden in Spain. Heart failure units have been developed to systematize the diagnosis, treatment, and clinical follow-up of heart failure patients, provide a structure to coordinate the actions of various entities and personnel involved in patient care, and improve prognosis and quality of life. There is ample evidence on the benefits of heart failure units or programs, which have become widespread in Spain. One of the challenges to the analysis of heart failure units is standardization of their classification, by determining which "programs" can be identified as heart failure "units" and by characterizing their complexity level. The aim of this article was to present the standards developed by the Spanish Society of Cardiology to classify and establish the requirements for heart failure units within the SEC-Excellence project. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Consideration of the relevance of standard quality techniques in Mass Customisation

    OpenAIRE

    Brabazon, Philip G.; MacCarthy, Bart L.

    2007-01-01

    The business philosophy of Mass Customisation (MC) implies rapid response to customer requests, high efficiency and limited cost overheads of customisation. Furthermore, it also implies the quality benefits of the mass production paradigm are guaranteed. However, traditional quality science in manufacturing is premised on volume production of uniform products rather than of differentiated products associated with MC. This creates quality challenges and raises questions over the suitability ...

  11. Impact of National Ambient Air Quality Standards Nonattainment Designations on Particulate Pollution and Health.

    Science.gov (United States)

    Zigler, Corwin M; Choirat, Christine; Dominici, Francesca

    2018-03-01

    Despite dramatic air quality improvement in the United States over the past decades, recent years have brought renewed scrutiny and uncertainty surrounding the effectiveness of specific regulatory programs for continuing to improve air quality and public health outcomes. We employ causal inference methods and a spatial hierarchical regression model to characterize the extent to which a designation of "nonattainment" with the 1997 National Ambient Air Quality Standard for ambient fine particulate matter (PM2.5) in 2005 causally affected ambient PM2.5 and health outcomes among over 10 million Medicare beneficiaries in the Eastern United States in 2009-2012. We found that, on average across all retained study locations, reductions in ambient PM2.5 and Medicare health outcomes could not be conclusively attributed to the nonattainment designations against the backdrop of other regional strategies that impacted the entire Eastern United States. A more targeted principal stratification analysis indicates substantial health impacts of the nonattainment designations among the subset of areas where the designations are estimated to have actually reduced ambient PM2.5 beyond levels achieved by regional measures, with noteworthy reductions in all-cause mortality, chronic obstructive pulmonary disorder, heart failure, ischemic heart disease, and respiratory tract infections. These findings provide targeted evidence of the effectiveness of local control measures after nonattainment designations for the 1997 PM2.5 air quality standard.

  12. High-Voltage-Input Level Translator Using Standard CMOS

    Science.gov (United States)

    Yager, Jeremy A.; Mojarradi, Mohammad M.; Vo, Tuan A.; Blalock, Benjamin J.

    2011-01-01

    proposed integrated circuit would translate (1) a pair of input signals having a low differential potential and a possibly high common-mode potential into (2) a pair of output signals having the same low differential potential and a low common-mode potential. As used here, "low" and "high" refer to potentials that are, respectively, below or above the nominal supply potential (3.3 V) at which standard complementary metal oxide/semiconductor (CMOS) integrated circuits are designed to operate. The input common-mode potential could lie between 0 and 10 V; the output common-mode potential would be 2 V. This translation would make it possible to process the pair of signals by use of standard 3.3-V CMOS analog and/or mixed-signal (analog and digital) circuitry on the same integrated-circuit chip. A schematic of the circuit is shown in the figure. Standard 3.3-V CMOS circuitry cannot withstand input potentials greater than about 4 V. However, there are many applications that involve low-differential-potential, high-common-mode-potential input signal pairs and in which standard 3.3-V CMOS circuitry, which is relatively inexpensive, would be the most appropriate circuitry for performing other functions on the integrated-circuit chip that handles the high-potential input signals. Thus, there is a need to combine high-voltage input circuitry with standard low-voltage CMOS circuitry on the same integrated-circuit chip. The proposed circuit would satisfy this need. In the proposed circuit, the input signals would be coupled into both a level-shifting pair and a common-mode-sensing pair of CMOS transistors. The output of the level-shifting pair would be fed as input to a differential pair of transistors. The resulting differential current output would pass through six standoff transistors to be mirrored into an output branch by four heterojunction bipolar transistors. The mirrored differential current would be converted back to potential by a pair of diode-connected transistors

  13. Quality between mechanical compression on reducible stretcher versus manual compression on standard stretcher in small elevator.

    Science.gov (United States)

    Kim, Tae Han; Hong, Ki Jeong; Sang Do, Shin; Kim, Chu Hyun; Song, Sung Wook; Song, Kyoung Jun; Ro, Young Sun; Ahn, Ki Ok; Jang, Dayea Beatrice

    2016-08-01

    Manual cardiopulmonary resuscitation (CPR) during vertical transport in small elevators using standard stretcher for out-of-hospital cardiac arrest can raise concerns with diminishing quality. Mechanical CPR on a reducible stretcher (RS-CPR) that can be shortened in the length was tested to compare the CPR quality with manual CPR on a standard stretcher (SS-CPR). A randomized crossover manikin simulation was designed. Three teams of emergency medical technicians were recruited to perform serial CPR simulations using two different protocols (RS-CPR and SS-CPR) according to a randomization; the first 6 minutes of manual CPR at the scene was identical for both scenarios and two different protocols during vertical transport in a small elevator followed on a basis of cross-over assignment. The LUCAS-2 Chest Compression System (Zolife AB, Lund, Sweden) was used for RS-CPR. CPR quality was measured using a resuscitation manikin (Resusci Anne QCPR, Laerdal Medical, Stavanger, Norway) in terms of no flow fraction, compression depth, and rate (median and IQR). A total of 42 simulations were analyzed. CPR quality did not differ significantly at the scene. No flow fraction (%) was significantly lower when the stretcher was moving in RS-CPR then SS-CPR (36.0 (33.8-38.7) vs 44.0 (36.8-54.4), P< .01). RS-CPR showed significantly better quality than SS-CPR; 93.2 (50.6-95.6) vs 14.8 (0-20.8) for adequate depth (P< 0.01), and 97.5 (96.6-98.2) vs 68.9(43.4-78.5) for adequate rate (P< .01). Mechanical CPR on a reducible stretcher during vertical transport showed significant improvement in CPR quality in terms of no-flow fraction, compression depth, and rate compared with manual CPR on a standard stretcher. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Effect of forage quality in faeces from different ruminant species fed high and low quality forage

    DEFF Research Database (Denmark)

    Jalali, A R; Nørgaard, P; Nielsen, M O

    2010-01-01

    Effect of forage quality in faeces from different ruminant species fed high and low quality forage......Effect of forage quality in faeces from different ruminant species fed high and low quality forage...

  15. Towards the proposal of an environmental quality standard for uranium in fresh water

    International Nuclear Information System (INIS)

    Beaugelin-Seiller, K.; Garnier-Laplace, J.; Gilbin, R.

    2009-01-01

    This report presents elements gathered by the IRSN to contribute to the determination of the standard of environmental quality related to uranium. After a presentation of values published by different bodies for the protection of the aquatic environment (water quality criteria), this report describes the determination of the fresh water chronic PNEC (Predicted No Effect Concentration) of uranium: method, available chronic eco-toxicity data and selection principles, PNEC obtained by applying safety factors or by statistical approach, PNEC per bio-availability domain, practical elements for a correct use of a PNEC. It finally proposes a PNEC for fresh water

  16. Effect of Fermentation Conditions and Plucking Standards of Tea Leaves on the Chemical Components and Sensory Quality of Fermented Juice

    Directory of Open Access Journals (Sweden)

    Ping Tang

    2018-01-01

    Full Text Available The effects of fermentation conditions (temperature, time, and pH and plucking standards (one leaf and a bud to four leaves and a bud on the chemical components and sensory quality of the fermented juices processed from crushed fresh tea leaves were investigated. The results showed that optimum fermentation conditions that resulted in fermented juices of the best sensory quality and the highest content of TFs were a temperature of 35°C, time duration of 75 min, and pH 5.1. The fermented juices processed from new shoots with three leaves and a bud or four leaves and a bud afforded high overall acceptability and TF concentration. These differences arise because tea leaves with different plucking standards have different catechin content and enzyme activities. Fermented tea juice possessed higher concentrations of chemical components such as soluble solids, amino acids, and TFs and exhibited better sensory quality as compared to black tea infusion. The TF concentrations decreased as the pH of the fermenting juice increased, and the fermented juice showed the best overall acceptability. These results provide essential information for the improvement of the processing of black tea beverage by suggesting fermentation of fresh tea leaves as a better alternative to their infusion.

  17. Ovarian stimulation and embryo quality

    NARCIS (Netherlands)

    Baart, Esther; Macklon, Nick S.; Fauser, Bart J. C. M.

    To Study the effects of different ovarian stimulation approaches on oocyte and embryo quality, it is imperative to assess embryo quality with a reliable and objective method. Embryos rated as high quality by standardized morphological assessment are associated with higher implantation and pregnancy

  18. Evaluation of the New DIN Standard for Quality Assurance of Diagnostic Displays - Technical Review DIN 6868-157.

    Science.gov (United States)

    Entz, Kathrin; Sommer, Alexander; Lenzen, Horst

    2018-01-01

    Acceptance and regular constancy tests are necessary to ensure the quality of diagnostic displays. In November 2014, a new standard (DIN 6868-157) was published which defines the test procedure and limiting values. There are several substantial changes compared with the previous standard DIN V 6868-57, i. e. considering the complete image display system including workstation and application software instead of only the displays. Since its publication, the new standard has raised many questions. This technical review aims to show the strengths and weaknesses of the new standard. Positive aspects are the introduction of a limiting value for the illuminance and the extension of the interval for constancy tests from 3 to 6 six months. The daily constancy test on the other hand, raises several problems and should be replaced by a randomized test. Additionally, the medical relevance is critically questioned and an overview of software for the quality assurance will be given.   · Acceptance and constancy tests for diagnostic displays are defined in DIN 6868-157.. · The new standards has positive and negative aspects.. · Randomized tests should be introduced.. · Entz K, Sommer A, Lenzen H. DIN 6868-157: Image Quality Assurance in Diagnostic X-ray Departments - X-ray Ordinance Acceptance and Constancy Test of Image Display Systems in their Environment - Technical Review -. Fortschr Röntgenstr 2018; 190: 51 - 60. © Georg Thieme Verlag KG Stuttgart · New York.

  19. TOTAL QUALITY MANAGEMENT IN HIGH EDUCATION

    Directory of Open Access Journals (Sweden)

    Hasan SERİN, Alper AYTEKİN

    2009-01-01

    Full Text Available The approach of Total Quality Management (TQM has been even more common and most recently its use in high education has been discussed. Likewise the enterprises producing various products, universities have also inputs, processes, and outputs. Due to conditions of competition, universities have to improve the qualities of these inputs, processes, and outputs, according to satisfaction, demands, and expectations of internal and external customers. If the TQM has been implemented in the universities with a manner that aims for customer satisfaction (students, lecturers, public and private establishments, and families, supports constant development, ensures participatory approach, and encourages working in groups, it will provide universities with effectiveness, efficiency, dynamics, and economics. In this study, common problems of universities, definitions of quality and TQM in high education, customer concept at universities, and factors affecting the quality of education have been explained. Besides, in order TQM approach to be successfully implemented in the universities, various suggestions have been presented.

  20. Quality beyond compliance.

    Science.gov (United States)

    Centanni, N; Monroe, M; White, L; Larson, R

    1999-01-01

    The service sector within the biopharmaceutical industry has experienced phenomenal growth over the past decade. In the highly regulated Good Laboratory Practices environment, the need for timely, high-quality service, accurate results, and on-time deliverables becomes paramount for the success and profitability of biopharmaceutical companies. The quality assurance process is a vital component of this drug product-development cycle and ensures compliance to the highest domestic and international regulatory standards. Quality-assurance professionals historically have held the role of independent auditors of the processes, who certify that results meet current standards of practice. Covance, a contract research organization that includes Good Laboratory Practices laboratories, reorganized and expanded the functional responsibilities of its quality assurance team in 1997. Auditors and quality assurance professionals have assumed roles beyond traditional compliance auditing and are forging new leadership and mentoring roles as process-improvement specialists. The results have been tangible, measurable benefits for clients and the Covance organization. This article provides an overview of this cultural change and the processes put in place to improve efficiency, productivity, and customer and employee satisfaction.

  1. Accounting for both local aquatic community composition and bioavailability in setting site-specific quality standards for zinc.

    Science.gov (United States)

    Peters, Adam; Simpson, Peter; Moccia, Alessandra

    2014-01-01

    Recent years have seen considerable improvement in water quality standards (QS) for metals by taking account of the effect of local water chemistry conditions on their bioavailability. We describe preliminary efforts to further refine water quality standards, by taking account of the composition of the local ecological community (the ultimate protection objective) in addition to bioavailability. Relevance of QS to the local ecological community is critical as it is important to minimise instances where quality classification using QS does not reconcile with a quality classification based on an assessment of the composition of the local ecology (e.g. using benthic macroinvertebrate quality assessment metrics such as River InVertebrate Prediction and Classification System (RIVPACS)), particularly where ecology is assessed to be at good or better status, whilst chemical quality is determined to be failing relevant standards. The alternative approach outlined here describes a method to derive a site-specific species sensitivity distribution (SSD) based on the ecological community which is expected to be present at the site in the absence of anthropogenic pressures (reference conditions). The method combines a conventional laboratory ecotoxicity dataset normalised for bioavailability with field measurements of the response of benthic macroinvertebrate abundance to chemical exposure. Site-specific QSref are then derived from the 5%ile of this SSD. Using this method, site QSref have been derived for zinc in an area impacted by historic mining activities. Application of QSref can result in greater agreement between chemical and ecological metrics of environmental quality compared with the use of either conventional (QScon) or bioavailability-based QS (QSbio). In addition to zinc, the approach is likely to be applicable to other metals and possibly other types of chemical stressors (e.g. pesticides). However, the methodology for deriving site-specific targets requires

  2. Analysis of high-quality modes in open chaotic microcavities

    International Nuclear Information System (INIS)

    Fang, W.; Yamilov, A.; Cao, H.

    2005-01-01

    We present a numerical study of the high-quality modes in two-dimensional dielectric stadium microcavities. Although the classical ray mechanics is fully chaotic in a stadium billiard, all of the high-quality modes show a 'strong scar' around unstable periodic orbits. When the deformation (ratio of the length of the straight segments over the diameter of the half circles) is small, the high-quality modes correspond to whispering-gallery-type trajectories and their quality factors decrease monotonically with increasing deformation. At large deformation, each high-quality mode is associated with multiple unstable periodic orbits. Its quality factor changes nonmonotonically with the deformation, and there exists an optimal deformation for each mode at which its quality factor reaches a local maximum. This unusual behavior is attributed to the interference of waves propagating along different constituent orbits that could minimize light leakage out of the cavity

  3. Quality Customer Service Action Plan

    International Nuclear Information System (INIS)

    2008-12-01

    Since its establishment in 1992 the RPII has been committed to the provision of high quality services to its customers. This report outlines how the RPII will work towards providing a high quality service to our customers and the standards we aim for in the provision of our services

  4. A reference standard-based quality assurance program for radiology.

    Science.gov (United States)

    Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J

    2010-01-01

    The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. [Quality assurance and certification of a hemodialysis unit according to the ISO-9001-2000 standards].

    Science.gov (United States)

    Arenas, M D; Gil, M T; Egea, J J; Sirvent, A E; Giménez, A

    2003-01-01

    We report the experience of three hemodialysis centers registered with the ISO 9001-2000 standard, regarding the development of a quality measure system and providing an analysis of this system and its advantages and disadvantages.

  6. Air kerma standardization for diagnostic radiology in a secondary standard laboratory

    International Nuclear Information System (INIS)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P.; Lopes, Ricardo T.

    2009-01-01

    The demand for calibration services and quality control in diagnostic radiology has grown in the country since the publication of the governmental regulation 453, issued by the Brazilian Ministry of Health in 1998. At that time, to produce results facing the new legislation, many laboratories used different standards and radiation qualities, some of which could be inadequate. The international standards neither supplied consistent radiation qualities and standardization for the different types of equipment available. This situation changed with the publication of the new edition of the IEC 61267 standard, published in 2005. The objective of this work was to implement the standardization of the air kerma for the unatenuated qualities (RQR) of IEC 61267 in the National Laboratory of Metrology of the Ionizing Radiations (LNMRI) of the Institute of Radiation Protection and Dosimetry (IRD). Technical procedures were developed together with uncertainty budget. Results of interlaboratory comparisons demonstrate that the quantity is standardized and internationally traceable. (author)

  7. Kurumsal Yönetim Standartları Ağırlıklandırılmış Kalite Analizi (Corporate Governance Standards Weighted Quality Analysis

    Directory of Open Access Journals (Sweden)

    İbrahim H. KAYRAL

    2016-03-01

    Full Text Available Providing health and health services always plays important role in maintenance of human life in a quality way and protection of its continuity. The most important factors to achieve health services quality are the structure of hospital management, institutionalization and the success of the strategic management process. It is closely associated with the hospital's level of institutionalization to achieve effectively managing hospital services in its complex structure. This study aims to achieve the standards of quality analysis of Corporate Services and Support Services Health Services dimensions of the Standards of Quality in Health Hospital Kit with the weighted Multidimensional Quality Model. For this purpose; by determining the distribution in terms of structure, process and outcomes technical and functional quality were evaluated by the analysis of standards and standards' points with the model. As a result, SKS-Hospital was found to have the strengths in terms of institutionalization and weaknesses on behalf ÇBKM and additionally SKS-Hospital has been proposed to strengthen the outcome-oriented standards for institutionalization and to improve the efficiency of hospital management.

  8. High Framingham risk score decreases quality of life in adults

    Directory of Open Access Journals (Sweden)

    Christian Yosaputra

    2010-04-01

    Full Text Available Cardiovascular disease (CVD risk factors, such as diabetes, hypertension, hypercholesterolemia, smoking, and obesity tend to occur together in the general population. Increasing prevalence of multiple CVD risk factors has been related to increased risk of death from coronary heart disease and stroke. Studies have suggested that people with several risk factors of CVD may have impaired health-related quality of life. The objective of this study was to assess the association of CVD risk factors with quality of life (QOL among adults aged 40 to 65 years. A cross-sectional study was conducted involving 220 subjects 40 - 65 years of age at a health center. The CVD risk factors were assessed using the Framingham risk score that is the standard instrument for assessment of the risk of a first cardiac event. The risk factors assessed were age, smoking, blood pressure, total cholesterol and high density lipoprotein cholesterol concentrations. QOL was assessed by means of the WHOQOL-BREF instrument that had been prevalidated. The results of the study showed that 28.2% of subjects were smokers, 56.4% had stage 1 hypertension, 42.8% high total cholesterol and 13.6% low HDL cholesterol. The high risk group amounted to 45.5% and 42.3% constitued an intermediate risk group. High CVD risk scores were significantly associated with a low QOL for all domains (physical, psychological, social and environment (p=0.000. Preventing or reducing the multiple CVD risk factors to improve QOL is necessary among adults.

  9. DAG expression: high-throughput gene expression analysis of real-time PCR data using standard curves for relative quantification.

    Directory of Open Access Journals (Sweden)

    María Ballester

    Full Text Available BACKGROUND: Real-time quantitative PCR (qPCR is still the gold-standard technique for gene-expression quantification. Recent technological advances of this method allow for the high-throughput gene-expression analysis, without the limitations of sample space and reagent used. However, non-commercial and user-friendly software for the management and analysis of these data is not available. RESULTS: The recently developed commercial microarrays allow for the drawing of standard curves of multiple assays using the same n-fold diluted samples. Data Analysis Gene (DAG Expression software has been developed to perform high-throughput gene-expression data analysis using standard curves for relative quantification and one or multiple reference genes for sample normalization. We discuss the application of DAG Expression in the analysis of data from an experiment performed with Fluidigm technology, in which 48 genes and 115 samples were measured. Furthermore, the quality of our analysis was tested and compared with other available methods. CONCLUSIONS: DAG Expression is a freely available software that permits the automated analysis and visualization of high-throughput qPCR. A detailed manual and a demo-experiment are provided within the DAG Expression software at http://www.dagexpression.com/dage.zip.

  10. Survey of image quality and patient dose in simple radiographic examinations: establishing guidance levels and comparison with international standards

    International Nuclear Information System (INIS)

    Manatrakul, N.; Bunsoong, T.; Krisanachinda, A.; Suwanpradit, P.; Rungruengthanakit, P.; Kanchart, S.; Chaiwong, Rajikorn; Tsapakig, V.A.

    2008-01-01

    Purpose: To investigate image quality and patient dose for commonly radiographic examinations in Thailand, to establish national reference or guidance levels (GL) and compare with international standards, as part of an International Atomic Energy Agency (IAEA) project on Radiation Protection of Patients and Medical Exposure Control (RAS/9/034 and RAS/9/047). Materials and Methods: Film reject rate analysis, image quality and patient dose assessment before and after Quality Control (QC) implementation were investigated in 8 X-ray machines in 4 hospitals. Air kerma (in mGy) at 1 meter focus-detector-distance for different kVp settings for each X-ray machines were measured using an ionization chamber under standardized condition. The entrance skin air kerma (ESAK) for Chest PA, Lumbar spine AP, Lumbar spine LAT, Pelvis AP, Abdomen AP, Skull AP and Skull LAT were calculated for at least 10 adult patients of average body mass (60 to 80 kg) for each projection. The obtained values were compared with international standards. Results: The highest film rejection rate reduction recorded after corrective actions from 9.15% to 6.8%. Mean ESAK values were less than international standards both before and after QC implementation in all projections but Chest PA projection. Maximum ESAK in Chest PA projection before corrective action was 0.55 mGy which was higher than the IAEA GL of 0.2 mGy. However, it was reduced to 0.25 mGy after QC tests on X- ray machine and using high kilovoltage (kV) technique. Conclusion: Proposed national GL of Thailand were obtained by estimating the 3rd quartile of the whole sample: Chest PA: 0.1 mGy, Lumbar Spine AP: 2.1 mGy, Lumbar Spine LAT: 6.3 mGy, Pelvis AP: 1.8 mGy, Abdomen: 1.5 mGy, Skull PA: 1.3 mGy and Skull LAT: 0.9 mGy. (author)

  11. Extralevator Abdominal Perineal Excision Versus Standard Abdominal Perineal Excision: Impact on Quality of the Resected Specimen and Postoperative Morbidity.

    Science.gov (United States)

    Habr-Gama, Angelita; São Julião, Guilherme P; Mattacheo, Adrian; de Campos-Lobato, Luiz Felipe; Aleman, Edgar; Vailati, Bruna B; Gama-Rodrigues, Joaquim; Perez, Rodrigo Oliva

    2017-08-01

    Abdominal perineal excision (APE) has been associated with a high risk of positive circumferential resection margin (CRM+) and local recurrence rates in the treatment of rectal cancer. An alternative extralevator approach (ELAPE) has been suggested to improve the quality of resection by avoiding coning of the specimen decreasing the risk of tumor perforation and CRM+. The aim of this study is to compare the quality of the resected specimen and postoperative complication rates between ELAPE and "standard" APE. All patients between 1998 and 2014 undergoing abdominal perineal excision for primary or recurrent rectal cancer at a single Institution were reviewed. Between 1998 and 2008, all patients underwent standard APE. In 2009 ELAPE was introduced at our Institution and all patients requiring APE underwent this alternative procedure (ELAPE). The groups were compared according to pathological characteristics, specimen quality (CRM status, perforation and failure to provide the rectum and anus in a single specimen-fragmentation) and postoperative morbidity. Fifty patients underwent standard APEs, while 22 underwent ELAPE. There were no differences in CRM+ (10.6 vs. 13.6%; p = 0.70) or tumor perforation rates (8 vs. 0%; p = 0.30) between APE and ELAPE. However, ELAPE were less likely to result in a fragmented specimen (42 vs. 4%; p = 0.002). Advanced pT-stage was also a risk factor for specimen fragmentation (p = 0.03). There were no differences in severe (Grade 3/4) postoperative morbidity (13 vs. 10%; p = 0.5). Perineal wound dehiscences were less frequent among ELAPE (52 vs 13%; p < 0.01). Despite short follow-up (median 21 mo.), 2-year local recurrence-free survival was better for patients undergoing ELAPE when compared to APE (87 vs. 49%; p = 0.04). ELAPE may be safely implemented into routine clinical practice with no increase in postoperative morbidity and considerable improvements in the quality of the resected specimen of patients with low rectal

  12. A standards-based approach to quality improvement for HIV services at Zambia Defence Force facilities: results and lessons learned.

    Science.gov (United States)

    Kols, Adrienne; Kim, Young-Mi; Bazant, Eva; Necochea, Edgar; Banda, Joseph; Stender, Stacie

    2015-07-01

    The Zambia Defence Force adopted the Standards-Based Management and Recognition approach to improve the quality of the HIV-related services at its health facilities. This quality improvement intervention relies on comprehensive, detailed assessment tools to communicate and verify adherence to national standards of care, and to test and implement changes to improve performance. A quasi-experimental evaluation of the intervention was conducted at eight Zambia Defence Force primary health facilities (four facilities implemented the intervention and four did not). Data from three previous analyses are combined to assess the effect of Standards-Based Management and Recognition on three domains: facility readiness to provide services; observed provider performance during antiretroviral therapy (ART) and antenatal care consultations; and provider perceptions of the work environment. Facility readiness scores for ART improved on four of the eight standards at intervention sites, and one standard at comparison sites. Facility readiness scores for prevention of mother-to-child transmission (PMTCT) of HIV increased by 15 percentage points at intervention sites and 7 percentage points at comparison sites. Provider performance improved significantly at intervention sites for both ART services (from 58 to 84%; P improved at intervention sites and declined at comparison sites; differences in trends between study groups were significant for eight items. A standards-based approach to quality improvement proved effective in supporting healthcare managers and providers to deliver ART and PMTCT services in accordance with evidence-based standards in a health system suffering from staff shortages.

  13. High beam quality and high energy short-pulse laser with MOPA

    Science.gov (United States)

    Jin, Quanwei; Pang, Yu; Jiang, JianFeng; Tan, Liang; Cui, Lingling; Wei, Bin; Sun, Yinhong; Tang, Chun

    2018-03-01

    A high energy, high beam quality short-pulse diode-pumped Nd:YAG master oscillator power-amplifier (MOPA) laser with two amplifier stages is demonstrated. The two-rod birefringence compensation was used as beam quality controlling methods, which presents a short-pulse energy of 40 mJ with a beam quality value of M2 = 1.2 at a repetition rate of 400Hz. The MOPA system delivers a short-pulse energy of 712.5 mJ with a pulse width of 12.4 ns.The method of spherical aberration compensation is improved the beam quality, a M2 factor of 2.3 and an optical-to-optical efficiency of 27.7% is obtained at the maximum laser out power.The laser obtained 1.4J out energy with polarization integration.

  14. High quality-factor optical resonators

    International Nuclear Information System (INIS)

    Henriet, Rémi; Salzenstein, Patrice; Coillet, Aurélien; Saleh, Khaldoun; Chembo, Yanne K; Ristic, Davor; Ferrari, Maurizio; Mortier, Michel; Rasoloniaina, Alphonse; Dumeige, Yannick; Féron, Patrice; Cibiel, Gilles; Llopis, Olivier

    2014-01-01

    Various resonators are investigated for microwave photonic applications. Micro-sphere, disk and fiber ring resonators were designed, realized and characterized. Obtained quality factors are as high as Q = 10 10 . (paper)

  15. Ultra-high energy physics and standard basic principles

    Directory of Open Access Journals (Sweden)

    Gonzalez-Mestres Luis

    2014-04-01

    Full Text Available It has not yet been elucidated whether the observed flux suppression for ultra-high energy cosmic rays (UHECR at energies above ≃ 4 x 1019 eV is a signature of the Greisen-Zatsepin-Kuzmin (GZK cutoff or a consequence of other phenomena. In both cases, violations of the standard fundamental principles of Physics can be present and play a significant role. They can in particular modify cosmic-ray interactions, propagation or acceleration at very high energy. Thus, in a long-term program, UHECR data can hopefully be used to test relativity, quantum mechanics, energy and momentum conservation, vacuum properties... as well as the elementariness of standard particles. Data on cosmic rays at energies ≃ 1020 eV may also be sensitive to new physics generated well beyond Planck scale. A typical example is provided by the search for possible signatures of a Lorentz symmetry violation (LSV associated to a privileged local reference frame (the "vacuum rest frame", VRF. If a VRF exists, the internal structure of standard particles at ultra-high energy can undergo substantial modifications. Similarly, the conventional particle symmetries may cease to be valid at such energies instead of heading to a grand unification and the structure of vacuum may no longer be governed by standard quantum field theory. Then, the question whether the notion of Planck scale still makes sense clearly becomes relevant and the very grounds of Cosmology can undergo essential modifications. UHECR studies naturally interact with the interpretation of WMAP and Planck observations. Recent Planck data analyses tend to confirm the possible existence of a privileged space direction. If the observed phenomenon turns out to be a signature of the spinorial space-time (SST we suggested in 1996-97, then conventional Particle Physics may correspond to the local properties of standard matter at low enough energy and large enough distances. This would clearly strengthen the cosmological

  16. The Legislative Requirements for Measuring Quality in Transnational Education: Understanding Divergence While Maintaining Standards

    Science.gov (United States)

    Bentley, Duncan; Henderson, Fiona; Lim, Choon Boey

    2017-01-01

    Australian universities have been actively engaged in transnational education since the 1990s. The challenges of assuring quality have seen a changing regulatory framework increasingly designed to ensure equivalence of standards wherever a course of study is offered and however it is delivered. Transnational Higher Education has grown…

  17. Quality system for Medical laboratories

    Directory of Open Access Journals (Sweden)

    Shiva Raj K.C.

    2015-03-01

    Full Text Available According to William Edwards Deming “Good quality does not necessarily mean high quality. Instead it means a predicable degree of uniformity and dependability at low cost with a quality suited to the market.” Whereas according to famous engineer and management consultant Joseph M. Juran quality is “fitness for purpose”. It should meet the customers’ expectations and requirements, should be cost effective.ISO began in 1926 as the International Federation of the National Standardizing Associations (ISA. The name, "ISO" was derived from the Greek word "isos" meaning "equal". (The relation to standards is that if two objects meet the same standard, they should be equal. This name eliminates any confusion that could result from the translation of "International Organization for Standardization" into different languages which would lead to different acronyms.In health sector, quality plays pivotal role, as it is directly related to patient’s care. Earlier time, health service was simple, quite safe but ineffective. Now health care system is an organizational system with more complex processes to deliver care. Medical laboratory service is an integral part in patient’s management system. So, for everyone involved in the treatment of the patient, the accuracy, reliability and safety of those services must be the primary concerns. Accreditation is a significant enabler of quality, thereby delivering confidence to healthcare providers, clinicians, the medical laboratories and the patients themselves.ISO announced meeting in Philadelphia to form a technical committee to develop a new standard for medical laboratory quality. It took 7 years for the creation of a new Quality standard for medical laboratories. It was named as “ISO 15189” and was first published in 2003. The ISO has released three versions of the standard. The first two were released in 2003 and 2007. In 2012, a revised and updated version of the standard, ISO 15189

  18. Software Quality Assurance and Controls Standard

    Science.gov (United States)

    2010-04-27

    dassurance a wor pro uc s an processes comply with predefined provisions and plans. • According to International Standard (IS) 12207 – of the 44...from document (plan) focus to process focus – Alignment with framework standard IS 12207 software life cycle (SLC) processes with exact...Books and P blications IEEE Software and Systems Engineering curriculum ABET u Certified Software Development Professional Standards ISO /IEC

  19. 77 FR 39205 - Public Hearings for Proposed Rules-National Ambient Air Quality Standards for Particulate Matter

    Science.gov (United States)

    2012-07-02

    ..., respectively, and to make corresponding revisions to the data handling conventions for PM and ambient air.... Environmental Protection Agency, Office of Air Quality Planning and Standards, Ariel Rios Building, 1200...

  20. High-quality cardiopulmonary resuscitation: current and future directions.

    Science.gov (United States)

    Abella, Benjamin S

    2016-06-01

    Cardiopulmonary resuscitation (CPR) represents the cornerstone of cardiac arrest resuscitation care. Prompt delivery of high-quality CPR can dramatically improve survival outcomes; however, the definitions of optimal CPR have evolved over several decades. The present review will discuss the metrics of CPR delivery, and the evidence supporting the importance of CPR quality to improve clinical outcomes. The introduction of new technologies to quantify metrics of CPR delivery has yielded important insights into CPR quality. Investigations using CPR recording devices have allowed the assessment of specific CPR performance parameters and their relative importance regarding return of spontaneous circulation and survival to hospital discharge. Additional work has suggested new opportunities to measure physiologic markers during CPR and potentially tailor CPR delivery to patient requirements. Through recent laboratory and clinical investigations, a more evidence-based definition of high-quality CPR continues to emerge. Exciting opportunities now exist to study quantitative metrics of CPR and potentially guide resuscitation care in a goal-directed fashion. Concepts of high-quality CPR have also informed new approaches to training and quality improvement efforts for cardiac arrest care.

  1. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    Science.gov (United States)

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  2. 75 FR 39252 - Release of Final Documents Related to the Review of the National Ambient Air Quality Standards...

    Science.gov (United States)

    2010-07-08

    ... Quality Standards: Scope and Methods Plan for Health Risk and Exposure Assessment and Particulate Matter... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OAR-2007-0492; FRL-9171-8] Release of Final Documents...: Environmental Protection Agency (EPA). ACTION: Notice of Availability. SUMMARY: The Office of Air Quality...

  3. Engineering high quality medical software

    CERN Document Server

    Coronato, Antonio

    2018-01-01

    This book focuses on high-confidence medical software in the growing field of e-health, telecare services and health technology. It covers the development of methodologies and engineering tasks together with standards and regulations for medical software.

  4. The preparation of large standards for NDA measurements

    International Nuclear Information System (INIS)

    Guardini, S.

    1991-01-01

    The accuracy of a nuclear material balance determination is dependent on the reference materials used to calibrate. The calibration needs of nondestructive assay techniques differ from the needs of destructive techniques: nondestructive techniques use the reference materials more than once and can require larger masses of special nuclear material. Therefore, the expertise inherited from destructive methods is not destructive measurements. The procurement process for reference materials is expensive and complex. Careful specification of the desired attributes defines the required quality measures. A detailed procurement plan, agreed upon and documented before acquisition starts, is crucial to obtaining a set of high quality references materials. The acquisition of some recent Los Alamos standards and the Ispra PERLA (Performance Laboratory) standards are following such plans. To date, plutonium oxide standards of three burnups ranging to 2.5 kg and uranium oxide standards of four (high) enrichments ranging to 1.5 kg are in routine use for calibration, performance evaluation and training. In this paper, the authors discuss an alternative

  5. ISO certification pays off in quality improvement

    International Nuclear Information System (INIS)

    Vermeer, F.J.G.

    1992-01-01

    This paper reports that by obtaining and maintaining International Standards Organization (ISO) 9001 certification, a company can improve its quality control system, cut waste, and motivate its employees. In so doing it improves its competitive position in both international and domestic markets. The success of a number of countries (notably Japan) in the world markets has focused the attention of the industrialized countries on improving quality levels and striving for a unified, worldwide quality standard. This has been particularly true in Europe; with several countries competing in a single market, a common quality standard has been a highly desirable goal for decades. One of the first multinational quality standards evolved in the European Community, which is estimated to become a single market with a gross national product of $4.5 trillion by 1992. As a consequence, in 1987 the International Standards Organization created ISO 9000, a single standard to ensure uniform quality in products and services offered with this growing market. U.S. petroleum and natural gas companies must recognize and implement the ISO 9000 standards or possibly lose international markets. If the present worldwide trend towards ISO 9000 continues (and there is no reason to believe that it will not), the standards will be just as important in the domestic market

  6. Evaluating the U.S. Food Safety Modernization Act Produce Safety Rule Standard for Microbial Quality of Agricultural Water for Growing Produce.

    Science.gov (United States)

    Havelaar, Arie H; Vazquez, Kathleen M; Topalcengiz, Zeynal; Muñoz-Carpena, Rafael; Danyluk, Michelle D

    2017-10-09

    The U.S. Food and Drug Administration (FDA) has defined standards for the microbial quality of agricultural surface water used for irrigation. According to the FDA produce safety rule (PSR), a microbial water quality profile requires analysis of a minimum of 20 samples for Escherichia coli over 2 to 4 years. The geometric mean (GM) level of E. coli should not exceed 126 CFU/100 mL, and the statistical threshold value (STV) should not exceed 410 CFU/100 mL. The water quality profile should be updated by analysis of a minimum of five samples per year. We used an extensive set of data on levels of E. coli and other fecal indicator organisms, the presence or absence of Salmonella, and physicochemical parameters in six agricultural irrigation ponds in West Central Florida to evaluate the empirical and theoretical basis of this PSR. We found highly variable log-transformed E. coli levels, with standard deviations exceeding those assumed in the PSR by up to threefold. Lognormal distributions provided an acceptable fit to the data in most cases but may underestimate extreme levels. Replacing censored data with the detection limit of the microbial tests underestimated the true variability, leading to biased estimates of GM and STV. Maximum likelihood estimation using truncated lognormal distributions is recommended. Twenty samples are not sufficient to characterize the bacteriological quality of irrigation ponds, and a rolling data set of five samples per year used to update GM and STV values results in highly uncertain results and delays in detecting a shift in water quality. In these ponds, E. coli was an adequate predictor of the presence of Salmonella in 150-mL samples, and turbidity was a second significant variable. The variability in levels of E. coli in agricultural water was higher than that anticipated when the PSR was finalized, and more detailed information based on mechanistic modeling is necessary to develop targeted risk management strategies.

  7. Impact of model uncertainty on soil quality standards for cadmium in rice paddy fields

    NARCIS (Netherlands)

    Römkens, P.F.A.M.; Brus, D.J.; Guo, H.Y.; Chu, C.L.; Chiang, C.M.; Koopmans, G.F.

    2011-01-01

    At present, soil quality standards used for agriculture do not consider the influence of pH and CEC on the uptake of pollutants by crops. A database with 750 selected paired samples of cadmium (Cd) in soil and paddy rice was used to calibrate soil to plant transfer models using the soil metal

  8. Quality Assurance Strategy for Existing Homes: Final Quality Management Primer for High Performing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Del Bianco, M.; Taggart, J.; Sikora, J.; Wood, A.

    2012-12-01

    This guide is designed to help Building America (BA) Teams understand quality management and its role in transitioning from conventional to high performance home building and remodeling. It explains what quality means, the value of quality management systems, the unique need for QMS when building high performing homes, and the first steps to a implementing a comprehensive QMS. This document provides a framework and context for BA teams when they encounter builders and remodelers.

  9. Quality Assurance Strategy for Existing Homes. Final Quality Management Primer for High Performing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Del Bianco, M. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Taggart, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Sikora, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Wood, A. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States)

    2012-12-01

    This guide is designed to help Building America (BA) teams understand quality management and its role in transitioning from conventional to high performance home building and remodeling. It explains what quality means, the value of quality management systems, the unique need for QMS when building high performing homes, and the first steps to a implementing a comprehensive QMS. This document provides a framework and context for BA teams when they encounter builders and remodelers.

  10. Quantitative chemical analysis for the standardization of copaiba oil by high resolution gas chromatography

    International Nuclear Information System (INIS)

    Tappin, Marcelo R.R.; Pereira, Jislaine F.G.; Lima, Lucilene A.; Siani, Antonio C.; Mazzei, Jose L.; Ramos, Monica F.S.

    2004-01-01

    Quantitative GC-FID was evaluated for analysis of methylated copaiba oils, using trans-(-)-caryophyllene or methyl copalate as external standards. Analytical curves showed good linearity and reproducibility in terms of correlation coefficients (0.9992 and 0.996, respectively) and relative standard deviation (< 3%). Quantification of sesquiterpenes and diterpenic acids were performed with each standard, separately. When compared with the integrator response normalization, the standardization was statistically similar for the case of methyl copalate, but the response of trans-(-)-caryophyllene was statistically (P < 0.05) different. This method showed to be suitable for classification and quality control of commercial samples of the oils. (author)

  11. Setting standards and monitoring quality in the NHS 1999-2013: a classic case of goal conflict.

    Science.gov (United States)

    Littlejohns, Peter; Knight, Alec; Littlejohns, Anna; Poole, Tara-Lynn; Kieslich, Katharina

    2017-04-01

    2013 saw the National Health Service (NHS) in England severely criticized for providing poor quality despite successive governments in the previous 15 years, establishing a range of new institutions to improve NHS quality. This study seeks to understand the contributions of political and organizational influences in enabling the NHS to deliver high-quality care through exploring the experiences of two of the major new organizations established to set standards and monitor NHS quality. We used a mixed method approach: first a cross-sectional, in-depth qualitative interview study and then the application of principal agent modeling (Waterman and Meier broader framework). Ten themes were identified as influencing the functioning of the NHS regulatory institutions: socio-political environment; governance and accountability; external relationships; clarity of purpose; organizational reputation; leadership and management; organizational stability; resources; organizational methods; and organizational performance. The organizations could be easily mapped onto the framework, and their transience between the different states could be monitored. We concluded that differing policy objectives for NHS quality monitoring resulted in central involvement and organizational change. This had a disruptive effect on the ability of the NHS to monitor quality. Constant professional leadership, both clinical and managerial, and basing decisions on best evidence, both technical and organizational, helped one institution to deliver on its remit, even within a changing political/policy environment. Application of the Waterman-Meier framework enabled an understanding and description of the dynamic relationship between central government and organizations in the NHS and may predict when tensions will arise in the future. © 2016 The Authors. The International Journal of Health Planning and Management Published by John Wiley & Sons Ltd. © 2016 The Authors. The International Journal of Health

  12. The radiological examination standards of East Germany as a means of quality assurance and radiation protection

    International Nuclear Information System (INIS)

    Angerstein, W.

    1988-01-01

    The standards (technical standards) define the minimum expenditure required for an X-ray examination. They must be reconfirmed about every 5 years. The regulations refer to basic care and do not restrict the possibility of carrying out additional examinations. Their observance ensures an optimum quality of the diagnosis and an optimum comparability of the pictures and a radiation burden that is as low as possible under realizable conditions (expenditure). The standards regulate the extent of the examinations (minimal number of the pictures to be taken) and also the periodic sequence of the pictures in the case of angiocardiographies. Some types of examinations require special standards for examinations of adults and children. (orig./DG) [de

  13. Limitations of ambient air quality standards in evaluating indoor environments

    International Nuclear Information System (INIS)

    Peterson, J.E.

    1992-01-01

    Analysis of the kinds of data used for the derivation of ambient air quality standards (AAQSs) for carbon monoxide and ozone shows that these values are based on the toxicology of the materials and thus are suitable for evaluating potential health effects of indoor environments, especially on the very young, the aged, and the infirm. A similar analysis shows that the AAQSs for suspended particulate matter, nitrogen dioxide, and sulfur dioxide are strictly empirical and that they should not be used for any but their first, intended purpose. The AAQSs for non-methane hydrocarbons are based on photochemical smog production, not injury of any kind, and have no utility for indoor environment evaluation

  14. Investigating the Availability of Quality Assurance Standards of Academic Programs in the Music Teacher Preparation Program- University of Jordan, from the Students’ Perspective

    Directory of Open Access Journals (Sweden)

    Nedal M. Nsairat

    2017-08-01

    Full Text Available This study aimed to find out how far quality assurance standards were applied in the music teacher preparation program at the University of Jordan, from the viewpoint of the students enrolled in the same program. The population of this study consisted of all the students (53 enrolled in the program , and majoring in music education and music performance. The study followed a descriptive analytical approach to collect the data. The study results revealed the extent of relevance of the BA program of preparing music teachers in the University of Jordan, which came as a result of applying each quality assurance standard in the program except the standard of facilities and equipment. In light of the findings, the study recommended that all those in charge of the educational process should pay more heed to certification programs of music teacher education. This should be done by designing and implementing programs to support this type of program, so as to be in conformity with quality assurance standards of music teacher education. Keywords: Preparation , Music teacher education , Standard , Quality assurance.

  15. High quality transmission Kikuchi diffraction analysis of deformed alloys - Case study

    International Nuclear Information System (INIS)

    Tokarski, Tomasz; Cios, Grzegorz; Kula, Anna; Bała, Piotr

    2016-01-01

    Modern scanning electron microscopes (SEM) equipped with thermally assisted field emission guns (Schottky FEG) are capable of imaging with a resolution in the range of several nanometers or better. Simultaneously, the high electron beam current can be used, which enables fast chemical and crystallographic analysis with a higher resolution than is normally offered by SEM with a tungsten cathode. The current resolution that limits the EDS and EBSD analysis is related to materials' physics, particularly to the electron-specimen interaction volume. The application of thin, electron-transparent specimens, instead of bulk samples, improves the resolution and allows for the detailed analysis of very fine microstructural features. Beside the typical imaging mode, it is possible to use a standard EBSD camera in such a configuration that only transmitted and scattered electrons are detected. This modern approach was successfully applied to various materials giving rise to significant resolution improvement, especially for the light element magnesium based alloys. This paper presents an insight into the application of the transmission Kikuchi diffraction (TKD) technique applied to the most troublesome, heavily-deformed materials. In particular, the values of the highest possible acquisition rates for high resolution and high quality mapping were estimated within typical imaging conditions of stainless steel and magnesium-yttrium alloy. - Highlights: •Monte Carlo simulations were used to simulate EBSD camera intensity for various measuring conditions. •Transmission Kikuchi diffraction parameters were evaluated for highly deformed, light and heavy elements based alloys. •High quality maps with 20 nm spatial resolution were acquired for Mg and Fe based alloys. •High speed TKD measurements were performed at acquisition rates comparable to the reflection EBSD.

  16. Delivering high quality hip fracture rehabilitation: the perspective of occupational and physical therapy practitioners.

    Science.gov (United States)

    Leland, Natalie E; Lepore, Michael; Wong, Carin; Chang, Sun Hwa; Freeman, Lynn; Crum, Karen; Gillies, Heather; Nash, Paul

    2018-03-01

    The majority of post-acute hip fracture rehabilitation in the US is delivered in skilled nursing facilities (SNFs). Currently, there are limited guidelines that equip occupational and physical therapy practitioners with a summary of what constitutes evidence-based high quality rehabilitation. Thus, this study aimed to identify rehabilitation practitioners' perspectives on the practices that constitute high quality hip fracture rehabilitation. Focus groups were conducted with 99 occupational and physical therapy practitioners working in SNFs in southern California. Purposive sampling of facilities was conducted to capture variation in key characteristics known to impact care delivery for this patient population (e.g., financial resources, staffing, and patient case-mix). Questions aimed to elicit practitioners' perspectives on high quality hip fracture rehabilitation practices. Each session was audio-recorded and transcribed. Data were systematically analyzed using a modified grounded theory approach. Seven themes emerged: objectives of care; first 72 h; positioning, pain, and precautions; use of standardized assessments; episode of care practices; facilitating insight into progress; and interdisciplinary collaboration. Clinical guidelines are critical tools to facilitate clinical decision-making and achieve desired patient outcomes. The findings of this study highlight the practitioners' perspective on what constitutes high quality hip fracture rehabilitation. This work provides critical information to advance the development of stakeholder-driven rehabilitation clinical guidelines. Future research is needed to verify the findings from other stakeholders (e.g., patients), ensure the alignment of our findings with current evidence, and develop measures for evaluating their delivery and relationship to desired outcomes. Implications for Rehabilitation This study highlights occupational and physiotherapy therapy practitioners' perspectives on the cumulative best

  17. Inequality in Preschool Quality? Community-Level Disparities in Access to High-Quality Learning Environments

    Science.gov (United States)

    Bassok, Daphna; Galdo, Eva

    2016-01-01

    In recent years, unequal access to high-quality preschool has emerged as a growing public policy concern. Because of data limitations, it is notoriously difficult to measure disparities in access to early learning opportunities across communities and particularly challenging to quantify gaps in access to "high-quality" programs. Research…

  18. Sensory Quality of Standard and Light Mayonnaise during Storage

    Directory of Open Access Journals (Sweden)

    Romana Karas

    2002-01-01

    Full Text Available The effects of ingredients on the quality and stability of two kinds of mayonnaise after it has been stored in a refrigerator (t = 5–8 °C and at room temperature (t = 20–25 °C were examined in this research. Fresh mayonnaise samples were examined by sensory analysis (analytical descriptive test and physico-chemical analyses (pH, acid and peroxide values first after being stored for one month and then after two months. The effects of individual factors were examined and the results were statistically valued. The results show that fresh standard mayonnaise containing 75 % of oil as opposed to low-fat mayonnaise (light mayonnaise containing 49 % of oil gained higher grades for most sensory attributes. Storage temperature, storage time and type of mayonnaise influence significantly (P≤0.001 the stability, homogeneity, mouth feeling, acid odour and flavour, rancidity, pH, acid and peroxide values. At any point of storage and under both temperature regimes, the samples of light mayonnaise had lower pH value and higher acid value in comparison with standard mayonnaise. Regardless of storage conditions irrespective of the recipe for their preparation, pH value was declining, whereas acid and peroxide values increased in all types of mayonnaise. Some meaningful statistically significant correlations (r > 0.70 exist between sensory and physico-chemical parametres of mayonnaise.

  19. Quality of record linkage in a highly automated cancer registry that relies on encrypted identity data

    Directory of Open Access Journals (Sweden)

    Schmidtmann, Irene

    2016-06-01

    Full Text Available Objectives: In the absence of unique ID numbers, cancer and other registries in Germany and elsewhere rely on identity data to link records pertaining to the same patient. These data are often encrypted to ensure privacy. Some record linkage errors unavoidably occur. These errors were quantified for the cancer registry of North Rhine Westphalia which uses encrypted identity data. Methods: A sample of records was drawn from the registry, record linkage information was included. In parallel, plain text data for these records were retrieved to generate a gold standard. Record linkage error frequencies in the cancer registry were determined by comparison of the results of the routine linkage with the gold standard. Error rates were projected to larger registries.Results: In the sample studied, the homonym error rate was 0.015%; the synonym error rate was 0.2%. The F-measure was 0.9921. Projection to larger databases indicated that for a realistic development the homonym error rate will be around 1%, the synonym error rate around 2%.Conclusion: Observed error rates are low. This shows that effective methods to standardize and improve the quality of the input data have been implemented. This is crucial to keep error rates low when the registry’s database grows. The planned inclusion of unique health insurance numbers is likely to further improve record linkage quality. Cancer registration entirely based on electronic notification of records can process large amounts of data with high quality of record linkage.

  20. Low-quality birds do not display high-quality signals: The cysteine-pheomelanin mechanism of honesty

    Science.gov (United States)

    Galván, Ismael; Wakamatsu, Kazumasa; Camarero, Pablo R; Mateo, Rafael; Alonso-Alvarez, Carlos

    2015-01-01

    The mechanisms that make that the costs of producing high-quality signals are unaffordable to low-quality signalers are a current issue in animal communication. The size of the melanin-based bib of male house sparrows Passer domesticus honestly signals quality. We induced the development of new bibs while treating males with buthionine-sulfoximine (BSO), a substance that depletes the levels of the antioxidant glutathione (GSH) and the amino acid cysteine, two elements that switch melanogenesis from eumelanin to pheomelanin. Final bib size is negatively related to pheomelanin levels in the bib feathers. BSO reduced cysteine and GSH levels in all birds, but improved phenotypes (bibs larger than controls) were only expressed by high-quality birds (BSO birds with largest bibs initially). Negative associations between final bib size and cysteine levels in erythrocytes, and between pheomelanin and cysteine levels, were observed in high-quality birds only. These findings suggest that a mechanism uncoupling pheomelanin and cysteine levels may have evolved in low-quality birds to avoid producing bibs of size not corresponding to their quality and greater relative costs. Indeed, greater oxidative stress in cells was not observed in low-quality birds. This may represent the first mechanism maintaining signal honesty without producing greater relative costs on low-quality signalers. PMID:25330349

  1. Quality in colonoscopy: European perspectives and practice

    NARCIS (Netherlands)

    Rees, Colin J.; Rajasekhar, Praveen T.; Rutter, Matthew D.; Dekker, Evelein

    2014-01-01

    Colonoscopy is the 'gold standard' investigation of the colon. High quality colonoscopy is essential to diagnose early cancer and reduce its incidence through the detection and removal of pre-malignant adenomas. In this review, we discuss the key components of a high quality colonoscopy, review

  2. Experience in the application of NUSS and Canadian quality assurance standards for overseas CANDU projects

    International Nuclear Information System (INIS)

    Simmons, R.B.V.; Thomas, R.A.

    1984-10-01

    The Canadian QA standards - the CSA Z299 series for manufacture, which first appeared in 1975, and the CSA N286 series for all other phases of plant life which appeared in 1979, have been based on experience with the CANDU reactor program. The CSA Technical Committee responsible for issue and for updating the two series have a direct liaison with the IAEA Technical Review Committee for Quality Assurance. Ontario Hydro, which has a substantial commitment to nuclear power using CANDU reactors, has played a large part in the Canadian QA standards program. Atomic Energy of Canada Limited has also taken a major part in the development of CSA QA standards. As a main contractor the Company has supplied CANDU plants in Canada and to Argentina, South Korea and Romania. Because of the compatibility of the Canadian QA standards used, the Embalse plant in Argentina and the Wolsung 1 plant in Korea, are essentially in compliance with NUSS QA standards. The plant under construction at Cernavoda in Romania similarly follows Canadian QA standards

  3. Re-Conceptualizing Extra Help for High School Students in a High Standards Era.

    Science.gov (United States)

    Balfanz, Robert; McPartland, James; Shaw, Alta

    The push for higher academic standards has resulted in an increase in the numbers of high school students needing extra help. The need for extra help is most pervasive in high-poverty areas and most high school students need extra help not in traditional basic elementary skills but in reading, mathematics, and advanced reasoning skills. Most…

  4. Emblems of Quality in Higher Education. Developing and Sustaining High-Quality Programs.

    Science.gov (United States)

    Haworth, Jennifer Grant; Conrad, Clifton F.

    This book proposes an "engagement" theory of program quality to evaluate and improve higher education programs at all degree levels. Based on interviews with 781 participants in a national study of Masters degree programs, it focuses on the interactive roles of students, faculty, and administrators in developing high-quality programs…

  5. Alternative quality standards in qualitative research?

    NARCIS (Netherlands)

    Poortman, Cindy Louise; Schildkamp, Kim

    2011-01-01

    Qualitative researchers often use other principles for judging the quality of their study than quantitative researchers. This inhibits a straightforward assessment of the quality and comparability of different types of studies, as well as decision-making about their usefulness for further research

  6. A fast transfer-free synthesis of high-quality monolayer graphene on insulating substrates by a simple rapid thermal treatment.

    Science.gov (United States)

    Wu, Zefei; Guo, Yanqing; Guo, Yuzheng; Huang, Rui; Xu, Shuigang; Song, Jie; Lu, Huanhuan; Lin, Zhenxu; Han, Yu; Li, Hongliang; Han, Tianyi; Lin, Jiangxiazi; Wu, Yingying; Long, Gen; Cai, Yuan; Cheng, Chun; Su, Dangsheng; Robertson, John; Wang, Ning

    2016-02-07

    The transfer-free synthesis of high-quality, large-area graphene on a given dielectric substrate, which is highly desirable for device applications, remains a significant challenge. In this paper, we report on a simple rapid thermal treatment (RTT) method for the fast and direct growth of high-quality, large-scale monolayer graphene on a SiO2/Si substrate from solid carbon sources. The stack structure of a solid carbon layer/copper film/SiO2 is adopted in the RTT process. The inserted copper film does not only act as an active catalyst for the carbon precursor but also serves as a "filter" that prevents premature carbon dissolution, and thus, contributes to graphene growth on SiO2/Si. The produced graphene exhibits a high carrier mobility of up to 3000 cm(2) V(-1) s(-1) at room temperature and standard half-integer quantum oscillations. Our work provides a promising simple transfer-free approach using solid carbon sources to obtain high-quality graphene for practical applications.

  7. MALDI-TOF MS for quality control of high protein content sport supplements.

    Science.gov (United States)

    De Ceglie, Cristina; Calvano, Cosima D; Zambonin, Carlo G

    2015-06-01

    High protein content sport nutritional supplements are found as powder products containing, as ingredients, amino acids and proteins with important nutritional values as milk, soy and egg proteins. An EU Food Supplements Directive (2002) requires that supplements should be safe, both in dosages and in purity. It is important, then, to develop rapid and sensitive methods to be employed for the quality control of these substances. In this work, we apply, for the first time, matrix-assisted laser desorption ionization-mass spectrometry as a fast, reproducible and sensitive method for the quality control of sport nutritional supplements based on proteins. To this aim, several commercial egg- and/or milk-based powder products have been processed by in gel or in solution digestion and analyzed in comparison to pure standard products. This strategy allowed to assess the reliability of the indications on proteins (as caseins, whey proteins and ovalbumin) declared in the label of several sport nutritional supplements. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. [Implementation of quality standard UNE-EN ISO/IEC 17043 in the External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology].

    Science.gov (United States)

    Poveda Gabaldón, Marta; Ovies, María Rosario; Orta Mira, Nieves; Serrano, M del Remedio Guna; Avila, Javier; Giménez, Alicia; Cardona, Concepción Gimeno

    2011-12-01

    The quality standard "UNE-EN-ISO 17043: 2010. Conformity assessment. General requirements for proficiency testing" applies to centers that organize intercomparisons in all areas. In the case of clinical microbiology laboratories, these intercomparisons must meet the management and technical standards required to achieve maximum quality in the performance of microbiological analysis and the preparation of test items (sample, product, data or other information used in the proficiency test) to enable them to be accredited. Once accredited, these laboratories can operate as a tool for quality control laboratories and competency assessment. In Spain, accreditation is granted by the Spanish Accreditation Body [Entidad Nacional de Acreditación (ENAC)]. The objective of this review is to explain how to apply the requirements of the standard to laboratories providing intercomparisons in the field of clinical microbiology (the organization responsible for all the tasks related to the development and operation of a proficiency testing program). This requires defining the scope and specifying the technical requirements (personnel management, control of equipment, facilities and environment, the design of the proficiency testing and data analysis for performance evaluation, communication with participants and confidentiality) and management requirements (document control, purchasing control, monitoring of complaints / claims, non-compliance, internal audits and management reviews). Copyright © 2011 Elsevier España S.L. All rights reserved.

  9. Issues related to the USEPA probabilistic standard for geologic disposal of high-level radioactive waste

    International Nuclear Information System (INIS)

    Okrent, D.

    1993-01-01

    This paper asks whether some of the fundamental bases for the 1985 USEPA standard on disposal of high level radioactive wastes (40 CFR Part 191) warrant re-examination. Similar questions also apply to the bases for the radioactive waste disposal requirements proposed by most other countries. It is suggested that the issue of intergenerational equity has been dealt with from too narrow a perspective. Not only should radioactive and nonradioactive hazardous waste disposal be regulated from a consistent philosophic basis, but the regulation of waste disposal itself should be embedded in the broader issues of intergenerational conservation of options, conservation of quality, and conservation of access. (author). 25 refs

  10. Fuzzy system for risk analysis in software projects through the attributes of quality standards iso 25000

    Directory of Open Access Journals (Sweden)

    Chau Sen Shia

    2014-02-01

    Full Text Available With the growth in demand for products and services in the IT area, companies encounter difficulties in establishing a metric or measure of quality of services to address measurably qualitative values in their planning. In this work fuzzy logic, standard SQuaRE (measurement of the quality of software products, Likertscale, GQM method (Goal-Question-Metric -indicator of quality of Software and the project risk analysis model of Boehm were used to assess the quality of services and decision-making, according to your demand and requests for software development. With the aim of improving the quality in the provision of services, the application is used to integrate the team and follow the life cycle of a project from its initial phase, and to assist in the comparison with the proposed schedule during the requirements elicitation.

  11. The comparison of high and standard definition computed ...

    African Journals Online (AJOL)

    The comparison of high and standard definition computed tomography techniques regarding coronary artery imaging. A Aykut, D Bumin, Y Omer, K Mustafa, C Meltem, C Orhan, U Nisa, O Hikmet, D Hakan, K Mert ...

  12. Electronic laboratory quality assurance program: A method of enhancing the prosthodontic curriculum and addressing accreditation standards.

    Science.gov (United States)

    Moghadam, Marjan; Jahangiri, Leila

    2015-08-01

    An electronic quality assurance (eQA) program was developed to replace a paper-based system and to address standards introduced by the Commission on Dental Accreditation (CODA) and to improve educational outcomes. This eQA program provides feedback to predoctoral dental students on prosthodontic laboratory steps at New York University College of Dentistry. The purpose of this study was to compare the eQA program of performing laboratory quality assurance with the former paper-based format. Fourth-year predoctoral dental students (n=334) who experienced both the paper-based and the electronic version of the quality assurance program were surveyed about their experiences. Additionally, data extracted from the eQA program were analyzed to identify areas of weakness in the curriculum. The study findings revealed that 73.8% of the students preferred the eQA program to the paper-based version. The average number of treatments that did not pass quality assurance standards was 119.5 per month. This indicated a 6.34% laboratory failure rate. Further analysis of these data revealed that 62.1% of the errors were related to fixed prosthodontic treatment, 27.9% to partial removable dental prostheses, and 10% to complete removable dental prostheses in the first 18 months of program implementation. The eQA program was favored by dental students who have experienced both electronic and paper-based versions of the system. Error type analysis can yield the ability to create customized faculty standardization sessions and refine the didactic and clinical teaching of the predoctoral students. This program was also able to link patient care activity with the student's laboratory activities, thus addressing the latest requirements of the CODA regarding the competence of graduates in evaluating laboratory work related to their patient care. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Long quantum channels for high-quality entanglement transfer

    International Nuclear Information System (INIS)

    Banchi, L; Apollaro, T J G; Cuccoli, A; Verrucchi, P; Vaia, R

    2011-01-01

    High-quality quantum-state and entanglement transfer can be achieved in an unmodulated spin bus operating in the ballistic regime, which occurs when the endpoint qubits A and B are nonperturbatively coupled to the chain by a suitable exchange interaction j 0 . Indeed, the transition amplitude characterizing the transfer quality exhibits a maximum for a finite optimal value j opt 0 (N), where N is the channel length. We show that j opt 0 (N) scales as N -1/6 for large N and that it ensures a high-quality entanglement transfer even in the limit of arbitrarily long channels, almost independently of the channel initialization. For instance, for any chain length the average quantum-state transmission fidelity exceeds 90% and decreases very little in a broad neighbourhood of j opt 0 (N). We emphasize that, taking the reverse point of view, should j 0 be experimentally constrained, high-quality transfer can still be obtained by adjusting the channel length to its optimal value. (paper)

  14. The History of Infant Formula: Quality, Safety, and Standard Methods.

    Science.gov (United States)

    Wargo, Wayne F

    2016-01-01

    Food-related laws and regulations have existed since ancient times. Egyptian scrolls prescribed the labeling needed for certain foods. In ancient Athens, beer and wines were inspected for purity and soundness, and the Romans had a well-organized state food control system to protect consumers from fraud or bad produce. In Europe during the Middle Ages, individual countries passed laws concerning the quality and safety of eggs, sausages, cheese, beer, wine, and bread; some of these laws still exist today. But more modern dietary guidelines and food regulations have their origins in the latter half of the 19th century when the first general food laws were adopted and basic food control systems were implemented to monitor compliance. Around this time, science and food chemistry began to provide the tools to determine "purity" of food based primarily on chemical composition and to determine whether it had been adulterated in any way. Since the key chemical components of mammalian milk were first understood, infant formulas have steadily advanced in complexity as manufacturers attempt to close the compositional gap with human breast milk. To verify these compositional innovations and ensure product quality and safety, infant formula has become one of the most regulated foods in the world. The present paper examines the historical development of nutritional alternatives to breastfeeding, focusing on efforts undertaken to ensure the quality and safety from antiquity to present day. The impact of commercial infant formulas on global regulations is addressed, along with the resulting need for harmonized, fit-for-purpose, voluntary consensus standard methods.

  15. Standards of Quality: Accreditation Guidelines Redesigned

    Science.gov (United States)

    Forsythe, Hazel; Andrews, Frances; Stanley, M. Sue; Anderson, Carol L.

    2011-01-01

    To ensure optimal standards for AAFCS program accreditation, the Council for Accreditation (CFA) conducted a review and revision of the "2001 AAFCS Standards for Accreditation." The CFA took a three-pronged approach including (a) a review of academic accreditations that had relationships to the FCS disciplines, (b) concept, content, and process…

  16. Large scale commercial fabrication of high quality graphene-based assays for biomolecule detection

    Science.gov (United States)

    Lerner, Mitchell; Gao, Yingning; Goldsmith, Brett; Barron, Francie

    Large numbers of high quality graphene transistors with mobility approximately 5000 cm2 / V * s were fabricated by chemical vapor deposition and packaged into ceramic carriers with an open cavity design. The ceramic carrier is compatible with standard electronics assembly, enabling the readout of graphene properties on the benchtop without large, expensive probing systems. After chemical functionalization, these sensors demonstrate sensitivity in the pM range and selectivity to many classes of biomolecules as a three terminal liquid-gated field effect transistor. High precision measurements of protein kinetics captured using this technology, commercially known as AGILE R100, are comparable and can exceed the capabilities of state-of-the-art biomolecule characterization tools. Recently published in Sensors and Actuators B

  17. Measurement quality assurance

    International Nuclear Information System (INIS)

    Eisenhower, E.H.

    1988-01-01

    The quality of a radiation protection program can be no better than the quality of the measurements made to support it. In many cases, that quality is unknown and is merely implied on the basis of a calibration of a measuring instrument. If that calibration is inappropriate or is performed improperly, the measurement result will be inaccurate and misleading. Assurance of measurement quality can be achieved if appropriate procedures are followed, including periodic quality control actions that demonstrate adequate performance. Several national measurement quality assurance (MQA) programs are operational or under development in specific areas. They employ secondary standards laboratories that provide a high-quality link between the National Bureau of Standards and measurements made at the field use level. The procedures followed by these secondary laboratories to achieve MQA will be described, as well as plans for similar future programs. A growing general national interest in quality assurance, combined with strong specific motivations for MQA in the area of ionizing radiation, will provide continued demand for appropriate national programs. Such programs must, however, employ procedures that are cost effective and must be developed with participation by all affected parties

  18. Identifying suitable substrates for high-quality graphene-based heterostructures

    Science.gov (United States)

    Banszerus, L.; Janssen, H.; Otto, M.; Epping, A.; Taniguchi, T.; Watanabe, K.; Beschoten, B.; Neumaier, D.; Stampfer, C.

    2017-06-01

    We report on a scanning confocal Raman spectroscopy study investigating the strain-uniformity and the overall strain and doping of high-quality chemical vapour deposited (CVD) graphene-based heterostuctures on a large number of different substrate materials, including hexagonal boron nitride (hBN), transition metal dichalcogenides, silicon, different oxides and nitrides, as well as polymers. By applying a hBN-assisted, contamination free, dry transfer process for CVD graphene, high-quality heterostructures with low doping densities and low strain variations are assembled. The Raman spectra of these pristine heterostructures are sensitive to substrate-induced doping and strain variations and are thus used to probe the suitability of the substrate material for potential high-quality graphene devices. We find that the flatness of the substrate material is a key figure for gaining, or preserving high-quality graphene.

  19. A lack of standardization: the basis for the ethical issues surrounding quality and performance reports.

    Science.gov (United States)

    Suchy, Kirsten

    2010-01-01

    Consumers in the United States are taking advantage of the proliferation of publicly available, internet-based performance reports and quality appraisals of health plans, healthcare organizations, hospitals, and physicians to aid in their healthcare decision making. However, these appraisal practices have given rise to controversy and debate over certain distinctive ethical issues. This article advocates a standardized ethical framework to guide current and future development and implementation of performance reports. This framework, which would resolve a number of the major issues, includes the following ethical principles to guide the practice of public reporting on the Internet and facilitate enhanced quality improvement in the healthcare industry: legitimacy, data integrity and quality, transparency, informed understanding, equity, privacy and confidentiality, collaboration, accountability, and evaluation and continuous improvement.

  20. Secondary standard dosimetry laboratory at INFLPR

    Energy Technology Data Exchange (ETDEWEB)

    Scarlat, F.; Minea, R.; Scarisoreanu, A.; Badita, E.; Sima, E.; Dumitrascu, M.; Stancu, E.; Vancea, C., E-mail: scarlat.f@gmail.com [National Institute for Laser, Plasma and Radiation Physics - INFLPR, Bucharest (Romania)

    2011-07-01

    National Institute for Laser, Plasma and Radiation Physics (INFLPR) has constructed a High Energy Secondary Standard Dosimetry Laboratory SSDL-STARDOOR - for performing dosimetric calibrations according to ISO IEC SR/EN 17025:2005 standards. This is outfitted with UNIDOS Secondary Standard Dosimeter from PTW (Freiburg Physikalisch-Technische Werksttaten) calibrated at the PTB-Braunschweig (German Federal Institute of Physics and Metrology). A radiation beam of the quality of Q used by our laboratory as calibration source are provided by INFLPR 7 MeV electron beam linear accelerator mounted in our facility. (author)

  1. A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality

    International Nuclear Information System (INIS)

    Favazza, Christopher P; Duan, Xinhui; Zhang, Yi; Yu, Lifeng; Leng, Shuai; Kofler, James M; Bruesewitz, Michael R; McCollough, Cynthia H

    2015-01-01

    Through this investigation we developed a methodology to evaluate and standardize CT image quality from routine abdomen protocols across different manufacturers and models. The influence of manufacturer-specific automated exposure control systems on image quality was directly assessed to standardize performance across a range of patient sizes. We evaluated 16 CT scanners across our health system, including Siemens, GE, and Toshiba models. Using each practice’s routine abdomen protocol, we measured spatial resolution, image noise, and scanner radiation output (CTDI vol ). Axial and in-plane spatial resolutions were assessed through slice sensitivity profile (SSP) and modulation transfer function (MTF) measurements, respectively. Image noise and CTDI vol values were obtained for three different phantom sizes. SSP measurements demonstrated a bimodal distribution in slice widths: an average of 6.2  ±  0.2 mm using GE’s ‘Plus’ mode reconstruction setting and 5.0  ±  0.1 mm for all other scanners. MTF curves were similar for all scanners. Average spatial frequencies at 50%, 10%, and 2% MTF values were 3.24  ±  0.37, 6.20  ±  0.34, and 7.84  ±  0.70 lp cm −1 , respectively. For all phantom sizes, image noise and CTDI vol varied considerably: 6.5–13.3 HU (noise) and 4.8–13.3 mGy (CTDI vol ) for the smallest phantom; 9.1–18.4 HU and 9.3–28.8 mGy for the medium phantom; and 7.8–23.4 HU and 16.0–48.1 mGy for the largest phantom. Using these measurements and benchmark SSP, MTF, and image noise targets, CT image quality can be standardized across a range of patient sizes. (paper)

  2. A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality.

    Science.gov (United States)

    Favazza, Christopher P; Duan, Xinhui; Zhang, Yi; Yu, Lifeng; Leng, Shuai; Kofler, James M; Bruesewitz, Michael R; McCollough, Cynthia H

    2015-11-07

    Through this investigation we developed a methodology to evaluate and standardize CT image quality from routine abdomen protocols across different manufacturers and models. The influence of manufacturer-specific automated exposure control systems on image quality was directly assessed to standardize performance across a range of patient sizes. We evaluated 16 CT scanners across our health system, including Siemens, GE, and Toshiba models. Using each practice's routine abdomen protocol, we measured spatial resolution, image noise, and scanner radiation output (CTDIvol). Axial and in-plane spatial resolutions were assessed through slice sensitivity profile (SSP) and modulation transfer function (MTF) measurements, respectively. Image noise and CTDIvol values were obtained for three different phantom sizes. SSP measurements demonstrated a bimodal distribution in slice widths: an average of 6.2  ±  0.2 mm using GE's 'Plus' mode reconstruction setting and 5.0  ±  0.1 mm for all other scanners. MTF curves were similar for all scanners. Average spatial frequencies at 50%, 10%, and 2% MTF values were 3.24  ±  0.37, 6.20  ±  0.34, and 7.84  ±  0.70 lp cm(-1), respectively. For all phantom sizes, image noise and CTDIvol varied considerably: 6.5-13.3 HU (noise) and 4.8-13.3 mGy (CTDIvol) for the smallest phantom; 9.1-18.4 HU and 9.3-28.8 mGy for the medium phantom; and 7.8-23.4 HU and 16.0-48.1 mGy for the largest phantom. Using these measurements and benchmark SSP, MTF, and image noise targets, CT image quality can be standardized across a range of patient sizes.

  3. THE VALUE RELEVANCE OF INTERNATIONAL ACCOUNTING STANDARD IMPLEMENTATION AND AUDIT QUALITY

    Directory of Open Access Journals (Sweden)

    Hanifa Zulhaimi

    2015-12-01

    Full Text Available The implementation of international accounting standards in Indonesia has significantly affected financial reporting. It increases information relevance for the investors because a fair value comprehensively represents assets and liabilities of an entity as of the balance sheet date. However, this triggers polemics over the value relevance of International Financial Reporting Standard (IFRS. This can be seen from stock price decline. This study aims to find out the effect of net income and other comprehensive income on stock price and to observe the effect of other comprehensive income moderated by audit quality. Furthermore this study also aims to find out the effect of  the subjectivity of OCI components. Using a sample of 79 companies, the writer analyzes 2014 financial statements derived from Indonesia Stock Exchange. Based on the result, the predetermined hypotheses are unable to prove. Net income is the only variable that affects stock return. Thus it can be concluded that net income has a value relevance for the investors in making economic decisions.

  4. E's Are Good: Standards of Quality in Public Administration as Reflected in Discourse on Canadian Public Policy Design

    Science.gov (United States)

    Baker, Dana Lee; Miller, Audrey Anna; Bratton, Todd

    2015-01-01

    Promoting understanding of quality in the context of good governance can be a challenging classroom exercise not only because of the potential for hijacking politicization of the discussion, but also because of the variety of ways in which public sector goals can be defined, even in the context of a single policy. Standards of quality in the…

  5. Quantity and quality of food losses along the Swiss potato supply chain: Stepwise investigation and the influence of quality standards on losses.

    Science.gov (United States)

    Willersinn, Christian; Mack, Gabriele; Mouron, Patrik; Keiser, Andreas; Siegrist, Michael

    2015-12-01

    This paper presents the results of a stepwise investigation of the quantity and quality of food losses along the Swiss potato supply chain. Quantitative data were collected from field trials, from structured interviews with wholesalers, processors and retailers, and from consumer surveys in combination with a 30-day diary study. The "Swiss trade customs for potatoes" pose the basis for the qualitative evaluation of losses. The influences of technological, institutional (business and economy; legislation and policy), and social drivers on the generation of fresh potato and processed potato products losses were assessed. Losses due to quality standards driven by food safety and consumer preferences for certain aesthetic standards have been evaluated too. Across the entire potato value chain, approximately 53-55% of the initial fresh potato production and 41-46% of the initial processing potato production are finally lost. Losses between organic and non-organic supply chains differ from 2% to 5%. From the total initial fresh potato production, 15-24% gets lost during agricultural production, a further 12-24% at wholesalers, 1-3% at retailers, and 15% at private households. In comparison, 5-11% of the initial production gets lost at wholesalers, a further 14-15% during processing, 0% at retailers, and 2% at private households. Losses during agricultural production do not vary much (13-25%) between fresh and processing potatoes. Approximately half of total potato losses occur because potatoes do not meet quality standards. 25-34% of these quality-driven losses are caused by food safety reasons, and the remainder are caused by consumer preferences or suitability for storage. In total, social drivers (e.g., consumer preferences, behavior, or socio-demographical factors) are responsible for two-thirds to three-fourths of all fresh potato losses and 40-45% of all processing potato losses. Technological drivers cause circa one-third of the total processing potato losses. The

  6. [European community guidelines and standards in indoor air quality: what proposals for Italy].

    Science.gov (United States)

    Settimo, Gaetano; D'Alessandro, Daniela

    2014-01-01

    Indoor air quality is an issue on which to focus because of the increasing number of exposed population and in view of the strong public feeling on this issue. This paper reports the rules of EU and several European countries about indoor air quality, focusing on the initiatives performed in Italy to respond to WHO recommendations. Several EU countries have introduced in their legislation rules relating to indoor air quality. At the moment, in Italy, a reference rule has not been issued. For this reason, up to date main informations concerning some guidelines or reference values in indoor air, to be used for a first comparison, are those obtained by the scientific literature, or by the guidelines issued by other European countries or, for analogy, by other standard values such as limit or reference values regarding outdoor air. Even the EU, while reaffirming the priority of energy efficiency measures, recommends healthier indoor environments and the development of a specific European strategy on the issue of indoor air quality. The National Study Group on indoor pollution of the Italian National Health Institute (ISS), is working for the development of shared technical and scientific documents, in order to provide greater uniformity of actions at national level, waiting for a legal framework for indoor air quality, in the light of the indication already produced by the WHO.

  7. Using a Standardized Task to Assess the Quality of Teacher-Child Dyadic Interactions in Preschool

    Science.gov (United States)

    Whittaker, Jessica E. V.; Williford, Amanda P.; Carter, Lauren M.; Vitiello, Virginia E.; Hatfield, Bridget E.

    2018-01-01

    Research Findings: This study explored the quality of teacher-child interactions within the context of a newly developed standardized task, Teacher-Child Structured Play Task (TC-SPT). A sample of 146 teachers and 345 children participated. Children who displayed the highest disruptive behaviors within each classroom were selected to participate.…

  8. Prodigious Effects of Concentration Intensification on Nanoparticle Synthesis: A High-Quality, Scalable Approach

    KAUST Repository

    Williamson, Curtis B.

    2015-12-23

    © 2015 American Chemical Society. Realizing the promise of nanoparticle-based technologies demands more efficient, robust synthesis methods (i.e., process intensification) that consistently produce large quantities of high-quality nanoparticles (NPs). We explored NP synthesis via the heat-up method in a regime of previously unexplored high concentrations near the solubility limit of the precursors. We discovered that in this highly concentrated and viscous regime the NP synthesis parameters are less sensitive to experimental variability and thereby provide a robust, scalable, and size-focusing NP synthesis. Specifically, we synthesize high-quality metal sulfide NPs (<7% relative standard deviation for Cu2-xS and CdS), and demonstrate a 10-1000-fold increase in Cu2-xS NP production (>200 g) relative to the current field of large-scale (0.1-5 g yields) and laboratory-scale (<0.1 g) efforts. Compared to conventional synthesis methods (hot injection with dilute precursor concentration) characterized by rapid growth and low yield, our highly concentrated NP system supplies remarkably controlled growth rates and a 10-fold increase in NP volumetric production capacity (86 g/L). The controlled growth, high yield, and robust nature of highly concentrated solutions can facilitate large-scale nanomanufacturing of NPs by relaxing the synthesis requirements to achieve monodisperse products. Mechanistically, our investigation of the thermal and rheological properties and growth rates reveals that this high concentration regime has reduced mass diffusion (a 5-fold increase in solution viscosity), is stable to thermal perturbations (64% increase in heat capacity), and is resistant to Ostwald ripening.

  9. CPD Aligned to Competency Standards to Support Quality Practice

    Directory of Open Access Journals (Sweden)

    Rose Nash

    2017-02-01

    Full Text Available As medication experts, pharmacists are key members of the patient’s healthcare team. Pharmacists must maintain their competence to practice to remain responsive to the increasingly complex healthcare sector. This paper seeks to determine how competence training for pharmacists may enhance quality in their professional development. Results of two separately administered surveys (2012 and 2013 were compared to examine the reported continued professional development (CPD practices of Australian pharmacists. Examination of results from both studies enabled a focus on how the competency standards inform CPD practice.In the survey administered in 2012, 91% (n = 253/278 pharmacists reported that they knew their current registration requirements. However, in the survey administered in 2013, only 43% (n = 46/107 reported utilization of the National Competency Standards Framework for Pharmacists in Australia (NCS to self-asses their practice as part of their annual re-registration requirements. Fewer, 23% (n = 25/107, used the NCS to plan their CPD. This may be symptomatic of poor familiarity with the NCS, uncertainty around undertaking self-directed learning as part of a structured learning plan and/or misunderstandings around what CPD should include. This is supported by thematic analysis of pharmacists’ social media comments. Initial and ongoing competence training to support meaningful CPD requires urgent attention in Australia. The competence (knowledge, skills and attributes required to engage in meaningful CPD practice should be introduced and developed prior to entry into practice; other countries may find they are in a similar position.

  10. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    Science.gov (United States)

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  11. Improving the quality of maternal and neonatal care: the role of standard based participatory assessments.

    Directory of Open Access Journals (Sweden)

    Giorgio Tamburlini

    Full Text Available BACKGROUND: Gaps in quality of care are seriously affecting maternal and neonatal health globally but reports of successful quality improvement cycles implemented at large scale are scanty. We report the results of a nation-wide program to improve quality of maternal and neonatal hospital care in a lower-middle income country focusing on the role played by standard-based participatory assessments. METHODS: Improvements in the quality of maternal and neonatal care following an action-oriented participatory assessment of 19 areas covering the whole continuum from admission to discharge were measured after an average period of 10 months in four busy referral maternity hospitals in Uzbekistan. Information was collected by a multidisciplinary national team with international supervision through visit to hospital services, examination of medical records, direct observation of cases and interviews with staff and mothers. Scores (range 0 to 3 attributed to over 400 items and combined in average scores for each area were compared with the baseline assessment. RESULTS: Between the first and the second assessment, all four hospitals improved their overall score by an average 0.7 points out of 3 (range 0.4 to 1, i.e. by 22%. The improvements occurred in all main areas of care and were greater in the care of normal labor and delivery (+0.9, monitoring, infection control and mother and baby friendly care (+0.8 the role of the participatory action-oriented approach in determining the observed changes was estimated crucial in 6 out of 19 areas and contributory in other 8. Ongoing implementation of referral system and new classification of neonatal deaths impede the improved process of care to be reflected in current statistics. CONCLUSIONS: Important improvements in the quality of hospital care provided to mothers and newborn babies can be achieved through a standard-based action-oriented and participatory assessment and reassessment process.

  12. Image quality of low-dose CCTA in obese patients: impact of high-definition computed tomography and adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Gebhard, Cathérine; Fuchs, Tobias A; Fiechter, Michael; Stehli, Julia; Stähli, Barbara E; Gaemperli, Oliver; Kaufmann, Philipp A

    2013-10-01

    The accuracy of coronary computed tomography angiography (CCTA) in obese persons is compromised by increased image noise. We investigated CCTA image quality acquired on a high-definition 64-slice CT scanner using modern adaptive statistical iterative reconstruction (ASIR). Seventy overweight and obese patients (24 males; mean age 57 years, mean body mass index 33 kg/m(2)) were studied with clinically-indicated contrast enhanced CCTA. Thirty-five patients underwent a standard definition protocol with filtered backprojection reconstruction (SD-FBP) while 35 patients matched for gender, age, body mass index and coronary artery calcifications underwent a novel high definition protocol with ASIR (HD-ASIR). Segment by segment image quality was assessed using a four-point scale (1 = excellent, 2 = good, 3 = moderate, 4 = non-diagnostic) and revealed better scores for HD-ASIR compared to SD-FBP (1.5 ± 0.43 vs. 1.8 ± 0.48; p ASIR as compared to 1.4 ± 0.4 mm for SD-FBP (p ASIR (388.3 ± 109.6 versus 350.6 ± 90.3 Hounsfield Units, HU; p ASIR vs. SD-ASIR respectively). Compared to a standard definition backprojection protocol (SD-FBP), a newer high definition scan protocol in combination with ASIR (HD-ASIR) incrementally improved image quality and visualization of distal coronary artery segments in overweight and obese individuals, without increasing image noise and radiation dose.

  13. The Impact of the Housing Quality on the Socio-Economic Standard of the EU Countries

    Directory of Open Access Journals (Sweden)

    Daniela Špirková

    2017-01-01

    Full Text Available The paper deals with the qualitative characteristics of the housing in the EU countries. On the one hand there is a problem with housing itself and on the other hand there is a problem with the housing quality with its significant impact on the quality of life. The housing quality is defined by the attributes mentioned in the EQLS survey. The examined characters are the dwelling stock, the space problem, the rot problem, the damp problem, the toilet problem, the bath problem, the garden problem, the rent problem, the utility problem and the heating problem. The housing quality is affected by the public expenses on the housing and the community amenities per capita. The relations between the qualitative characteristics mutually and the qualitative characteristics and the public expenditures on the housing and the community amenities are examined by the correlation and regression analysis. The aim of the article is to point out to the dependence between the expenses and the housing quality in the EU countries. The mentioned relation strongly implicates the socio-economic standard of these countries.

  14. A nuclear standard high-efficiency adsorber for iodine

    International Nuclear Information System (INIS)

    Wang Jianmin; Qian Yinge

    1988-08-01

    The structure of a nuclear standard high-efficiency adsorber, adsorbent and its performance are introduced. The performance and structure were compared with the same kind product of other firms. The results show that the leakage rate is less than 0.005%

  15. Evaluation of Arabic Language Learning Program for Non-Native Speakers in Saudi Electronic University According to Total Quality Standards

    Science.gov (United States)

    Alowaydhi, Wafa Hafez

    2016-01-01

    The current study aimed at standardizing the program of learning Arabic for non-native speakers in Saudi Electronic University according to certain standards of total quality. To achieve its purpose, the study adopted the descriptive analytical method. The author prepared a measurement tool for evaluating the electronic learning programs in light…

  16. Quality Management of University Education in Nigeria: an Appraisal

    African Journals Online (AJOL)

    Quality management in education is about all the various organized activities that culminate in the production of a given output that conforms to set standard. It is geared towards high standards and a zero tolerance level for wastage in the educational enterprise. This paper examined quality management of University ...

  17. Hot Water Treatment, Trunk Diseases and Other Critical Factors in the Production of High-Quality Grapevine Planting Material

    Directory of Open Access Journals (Sweden)

    H. Waite

    2007-04-01

    Full Text Available This review describes the critical factors on which successful grapevine propagation depends and discusses the steps that can be taken to improve the quality of planting material available to growers. Spasmodic occurrences of young vine decline and the failure of planting material have plagued the wine industry since the 1990s. The syndrome now described as Petri disease has been identified as the probable cause of many of the failures, but hot water treatment (HWT of dormant cuttings (50°C/30 min, for the control of Phaeomoniella chlamydospora and other endogenous pathogens, has also been implicated in the losses. HWT is known to cause a temporary switch to fermentative respiration and early retarded growth in treated material, particularly in Pinot Noir, but the effects of HWT on dormant vine tissue are not yet fully understood. Poor nursery hygiene and poor storage and handling practices during propagation and planting have also been implicated in vine failure. Demand for planting material has exceeded supply and there has been little incentive for nurseries to improve their standards. The quality of planting material could be significantly improved by changing nursery practices, particularly by discontinuing the practice of soaking cuttings in water, treated or untreated, and by improving general standards of nursery hygiene and the management of cool rooms. There is a need to develop a set of universal quality standards for cuttings and rooted vines. Growers also need to be made aware of the characteristics and benefits of high quality planting material.

  18. Irrigation Water Quality Standards for Indirect Wastewater Reuse in Agriculture: A Contribution toward Sustainable Wastewater Reuse in South Korea

    Directory of Open Access Journals (Sweden)

    Hanseok Jeong

    2016-04-01

    Full Text Available Climate change and the subsequent change in agricultural conditions increase the vulnerability of agricultural water use. Wastewater reuse is a common practice around the globe and is considered as an alternative water resource in a changing agricultural environment. Due to rapid urbanization, indirect wastewater reuse, which is the type of agricultural wastewater reuse that is predominantly practiced, will increase, and this can cause issues of unplanned reuse. Therefore, water quality standards are needed for the safe and sustainable practice of indirect wastewater reuse in agriculture. In this study, irrigation water quality criteria for wastewater reuse were discussed, and the standards and guidelines of various countries and organizations were reviewed to suggest preliminary standards for indirect wastewater reuse in South Korea. The proposed standards adopted a probabilistic consideration of practicality and classified the use of irrigation water into two categories: upland and rice paddy. The standards suggest guidelines for E. coli, electric conductivity (EC, turbidity, suspended solids (SS, biochemical oxygen demand (BOD, pH, odor, and trace elements. Through proposing the standards, this study attempts to combine features of both the conservative and liberal approaches, which in turn could suggest a new and sustainable practice of agricultural wastewater reuse.

  19. Quality management standards for facility services in the Italian health care sector.

    Science.gov (United States)

    Cesarotti, Vittorio; Di Silvio, Bruna

    2006-01-01

    Health care, one of the most dynamic sectors in Italy, is studied with a particular focus on outsourcing non-core activities such as facility management (FM) services. The project's goals are to define national standards to balance and control facility service evolution, and to drive FM services towards organisational excellence. The authors, in cooperation with a pool of facility service providers and hospitals managers, studied cleaning services--one of the most critical areas. This article describes the research steps and findings following definition and publication of the Italian standard and its application to an international benchmarking process. The method chosen for developing the Italian standard was to merge technical, strategic and organisational aspects with the goal of standardising the contracting system, giving service providers the chance to improve efficiency and quality, while helping healthcare organisations gain from a better, more reliable and less expensive service. The Italian standard not only improved services but also provided adequate control systems for outsourcing organisations. In this win-win context, it is hoped to continually drive FM services towards organisational excellence. This study is specific to the Italian national healthcare system. However, the strategic dynamics described are common to many other contexts. A systematic method for improving hospital FM services is presented. The authors believe that lessons learned from their Italian case study can be used to better understand and drive similar services in other countries or in other FM service outsourcing sectors.

  20. A pioneering application of NQA-1 quality assurance standards in the development of software

    International Nuclear Information System (INIS)

    Weisbin, A.N.

    1988-01-01

    The application of NQA-1 Quality Assurance Standards to computer software programs has been recent at the Oak Ridge National Laboratory. One reason for systematically applying quality assurance to computer software is the extensive use of results from computer programs. to characterize potential sites for nuclear waste repositories leading ultimately to important policy making decisions. Because data from these programs characterize the likely radioactivity profile for many hundreds of years, experimental validation is not feasible. The Sensitivity and Uncertainty Analysis Methods Development Project (SUAMDP) was developed to formulate and utilize efficient and comprehensive methods for determining sensitivities of calculated results with respect to changes in all input parameters. The computerized methodology was embodied in the Gradient Enhanced Software System (GRESS). Due to the fact that GRESS was to be used in the site characterization for waste storage, stringent NQA-1 requirements were imposed by the sponsor. A working relationship between the Oak Ridge National Laboratory (ORNL) Quality Department and the research scientists developing GRESS was essential in achieving understanding and acceptance of the quality assurance requirements as applied to the SUAMDP. The relationship resulted in the SUAMDP becoming the first software project at ORNL to develop a comprehensive NQA-1 Quality Assurance Plan; this plan now serves as a model for software quality assurance at ORNL. This paper describes the evolution of this plan and its impact on the application of quality assurance procedures to software

  1. MR imaging of the articular cartilage of the knee with arthroscopy as gold standard: assessment of methodological quality of clinical studies

    International Nuclear Information System (INIS)

    Duchateau, Florence; Berg, Bruno C. vande

    2002-01-01

    The purpose of this study was to assess the methodological quality of articles addressing the value of MR imaging of the knee cartilage with arthroscopy as a standard. Relevant papers were selected after Medline review (MEDLINE database search including the terms ''cartilage'' ''knee'', ''MR'' and ''arthroscopy''). Two observers reviewed independently 29 selected articles to determine how each study had met 15 individual standards that had been previously developed to assess the methodological quality of clinical investigations. The following criteria were met in variable percentage of articles including adequate definition of purpose (100%), statistical analysis (90%), avoidance of verification bias (86%), patient population description (83%), reference standard (79%), review bias (79%), study design (66%), inclusion criteria (41%) and method of analysis (41.5%), avoidance of diagnostic-review bias (24%), exclusion criteria (21%), indeterminate examination results (17%), analysis criteria (14%), interobserver reliability (14%) and intraobserver reliability (7%). The assessment of the methodological quality of clinical investigations addressing the value of MR imaging in the evaluation of the articular cartilage of the knee with arthroscopy as the standard of reference demonstrated that several standards were rarely met in the literature. Efforts should be made to rely on clearly defined lesion criteria and to determine reliability of the observations. (orig.)

  2. The FBI compression standard for digitized fingerprint images

    Energy Technology Data Exchange (ETDEWEB)

    Brislawn, C.M.; Bradley, J.N. [Los Alamos National Lab., NM (United States); Onyshczak, R.J. [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Hopper, T. [Federal Bureau of Investigation, Washington, DC (United States)

    1996-10-01

    The FBI has formulated national standards for digitization and compression of gray-scale fingerprint images. The compression algorithm for the digitized images is based on adaptive uniform scalar quantization of a discrete wavelet transform subband decomposition, a technique referred to as the wavelet/scalar quantization method. The algorithm produces archival-quality images at compression ratios of around 15 to 1 and will allow the current database of paper fingerprint cards to be replaced by digital imagery. A compliance testing program is also being implemented to ensure high standards of image quality and interchangeability of data between different implementations. We will review the current status of the FBI standard, including the compliance testing process and the details of the first-generation encoder.

  3. Building America Case Study: Standard- Versus High-Velocity Air Distribution in High-Performance Townhomes, Denver, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    2017-06-09

    IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore the small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements. Ultimately, the builder decided that adoption of these practices would be too disruptive midstream in the construction cycle. However, the townhomes met the ENERGY STAR Version 3.0 program requirements.

  4. Comparison of the image quality between volumetric and conventional high-resolution CT with 64-slice row CT

    International Nuclear Information System (INIS)

    Gao Yanli; Zhang Lei; Zhao Xia; Ma Min; Zhai Renyou

    2008-01-01

    Objective: To compare the image quality between volumetric high-resolution CT (VHRCT) and conventional high-resolution CT (CHRCT), and investigate the feasibility of VHRCT. Methods: Catphan 412 phantom was scanned with protocols of CHRCT and VHRCT on a set of GE Lightspeed VCT. The spatial-resolution (LP/cm), noise (standard deviation in an ROI) and radiation close (CTDI) were recorded for each CT scan. Difference of noise between CHRCT and VHRCT were evaluated by paired t test. In clinical study, 32 patients were scanned with VHRCT and CHRCT protocols. The image quality of CHRCT and VHRCT was rated and compared. The quality difference between CHRCT and VHRCT was assessed by Wilcoxon paired signed rank sum test. Results: In phantom study, the in-plane spatial-resolution of both VHRCT and CHRCT was 11 LP/cm for axial images and 12 LP/cm for coronal reformatted images. The noise of VHRCT and CHRCT was (69.18±2.77)HU and (54.62±2.12) HU respectively (t=-15.929, P 0.05). The quality assessment scores of VHRCT coronal reformatted images and CHRCT coronal reformatted images were 3.05 and 1.88 respectively with significant difference (Z= -5.088, P<0.01). Conclusion: The image quality of VHRCT cross-sectional image is similar to that of CHRCT. Multiplanar images with high resolution of VHRCT are recommended. The radiation dose of VHRCT remains to be optimized. (authors)

  5. Future of Software Engineering Standards

    Science.gov (United States)

    Poon, Peter T.

    1997-01-01

    In the new millennium, software engineering standards are expected to continue to influence the process of producing software-intensive systems which are cost-effetive and of high quality. These sytems may range from ground and flight systems used for planetary exploration to educational support systems used in schools as well as consumer-oriented systems.

  6. High quality data: An evaluation of AIM data quality and data quality procedures

    Science.gov (United States)

    The goal of every monitoring program is to collect high-quality data which can then be used to provide information to decision makers. The Bureau of Land Management (BLM) Assessment, Inventory, and Monitoring (AIM) program is one such data set which provides rangeland status, condition, and trend in...

  7. Students as Stakeholders in the Policy Context of the European Standards and Guidelines for Quality Assurance in Higher Education Institutions

    NARCIS (Netherlands)

    Logermann, Frauke; Leisyte, Liudvika; Curaj, Adrian; Matei, Liviu; Pricopie, Remus; Salmi, Jamil; Scott, Peter

    2015-01-01

    The European Standard and Guidelines for Quality Assurance (ESG) of 2005 can be defined as one of the major Bologna documents aimed at furthering the role of students as stakeholders in internal quality assurance processes at higher education institutions (HEIs). Still little is known about

  8. 76 FR 64810 - Beverages: Bottled Water Quality Standard; Establishing an Allowable Level for di(2-ethylhexyl...

    Science.gov (United States)

    2011-10-19

    .... FDA 1993-N-0259 (Formerly Docket No. 1993N-0085)] Beverages: Bottled Water Quality Standard... evidence from two studies puts previous concerns to rest concerning the effects of DEHP consumption in... increase costs for consumers for beverages packaged in plastic bottles. However, this rule does not...

  9. FINANCIAL ACCOUNTING QUALITY AND ITS DEFINING CHARACTERISTICS

    Directory of Open Access Journals (Sweden)

    Andra M. ACHIM

    2014-11-01

    Full Text Available The importance ofhigh-quality financial statements is highlighted by the main standard-setting institutions activating in the field of accounting and reporting. These have issued Conceptual Frameworks which state and describe the qualitative characteristics of accounting information. In this qualitative study, the research methodology consists of reviewing the literature related to the definition of accounting quality and striving for understanding how it can be explained. The main objective of the study is to identify the characteristics information should possess in order to be of high quality. These characteristics also contribute to the way of defining financial accounting quality. The main conclusions that arise from this research are represented by the facts that indeed financial accounting quality cannot be uniquely defined and that financial information is of good quality when it enhances the characteristics incorporated in the conceptual frameworks issued by both International Accounting Standards Board and Financial Accounting Standards Board.

  10. Surveying drinking water quality (Balikhlou River, Ardabil Province, Iran)

    Science.gov (United States)

    Aalipour erdi, Mehdi; Gasempour niari, Hassan; Mousavi Meshkini, Seyyed Reza; Foroug, Somayeh

    2018-03-01

    Considering the importance of Balikhlou River as one of the most important water sources of Ardabil, Nir and Sarein cities, maintaining water quality of this river is the most important goals in provincial and national levels. This river includes a wide area that provides agricultural, industrial and drinking water for the residents. Thus, surveying the quality of this river is important in planning and managing of region. This study examined the quality of river through eight physicochemical parameters (SO4, No3, BOD5, TDS, turbidity, pH, EC, COD) in two high- and low-water seasons by international and national standards in 2013. For this purpose, a review along the river has been done in five stations using t test and SPSS software. Model results showed that the amount difference in TDS and EC with WHO standards, and TDS rates with Iran standards in low-water seasons, pH and EC with WHO standards in high-water seasons, is not significant in high-water season; but for pH and SO4 parameters, turbidity and NO3 in both standards and EC value with WHO standard in low-water season and pH, EC, SO4 parameters and turbidity and NO3 in high-water season have significant difference from 5 to 1%, this shows the ideal limit and lowness of parameters for different usage.

  11. Health-related quality of life in children with high-functioning autism.

    Science.gov (United States)

    Potvin, Marie-Christine; Snider, Laurie; Prelock, Patricia A; Wood-Dauphinee, Sharon; Kehayia, Eva

    2015-01-01

    The health-related quality of life of school-aged children with high-functioning autism is poorly understood. The objectives of this study were to compare the health-related quality of life of children with high-functioning autism to that of typically developing peers and to compare child-self and parent-proxy reports of health-related quality of life of children. A cross-sectional study of children with high-functioning autism (n = 30) and peers (n = 31) was conducted using the Pediatric Quality of Life Inventory 4.0 Generic Core Scales. Children with high-functioning autism had significantly poorer health-related quality of life than peers whether reported by themselves (p children and parental scores suggested variance in points of view. This study specifically investigated health-related quality of life in children with high-functioning autism as compared to a sample of peers, from the child's perspective. It strengthens earlier findings that children with high-functioning autism experience poorer health-related quality of life than those without this disorder and points to the importance of clinicians working with families to identify areas in a child's life that promote or hinder their sense of well-being. © The Author(s) 2013.

  12. 40 CFR Appendix P to Part 50 - Interpretation of the Primary and Secondary National Ambient Air Quality Standards for Ozone

    Science.gov (United States)

    2010-07-01

    ... the data handling procedures for the reported data). 2.3Comparisons with the Primary and Secondary... Secondary National Ambient Air Quality Standards for Ozone P Appendix P to Part 50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY...

  13. 10 CFR 72.144 - Quality assurance program.

    Science.gov (United States)

    2010-01-01

    ... quality history and degree of standardization of the item. (d) The licensee, applicant for a license... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance program. 72.144 Section 72.144 Energy... NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C WASTE Quality...

  14. Assessment of three medical and research laboratories using WHO AFRO_SLIPTA Quality Standards in Southwestern Uganda: a long way to go.

    Science.gov (United States)

    Taremwa, Ivan Mugisha; Ampaire, Lucas; Iramiot, Jacob; Muhwezi, Obed; Matte, Aloysius; Itabangi, Herbert; Mbabazi, Hope; Atwebembeire, Jeninah; Kamwine, Monicah; Katawera, Victoria; Mbalibulha, Yona; Orikiriza, Patrick; Boum, Yap

    2017-01-01

    While the laboratory represents more than 70% of clinical diagnosis and patient management, access to reliable and quality laboratory diagnostics in sub-Saharan Africa remains a challenge. To gain knowledge and suggest evidence based interventions towards laboratory improvement in Southwestern Uganda, we assessed the baseline laboratory quality standards in three medical and research laboratories in Southwestern Uganda. We conducted a cross sectional survey from October, 2013 to April, 2014. Selected laboratories, including one private research, one private for profit and one public laboratory, were assessed using the WHO AFRO_SLIPTA checklist and baseline scores were determined. The three laboratories assessed met basic facility requirements, had trained personnel, and safety measures in place. Sample reception was properly designed and executed with a well designated chain of custody. All laboratories had sufficient equipment for the nature of work they were involved in. However, we found that standard operating procedures were incomplete in all three laboratories, lack of quality audit schemes by two laboratories and only one laboratory enrolled into external quality assurance schemes. The SLIPTA scores were one star for the research laboratory and no star for both the public and private-for-profit laboratories. While most of the laboratory systems were in place, the low scores obtained by the assessed laboratories reflect the need for improvement to reach standards of quality assured diagnostics in the region. Therefore, routine mentorship and regional supportive supervision are necessary to increase the quality of laboratory services.

  15. Improving voluntary medical male circumcision standards ...

    African Journals Online (AJOL)

    Voluntary medical male circumcision (VMMC) has been demonstrated to reduce the transmission of HIV by 60%. Scaling up VMMC services requires that they be of high quality, socially accepted, and effective. We evaluated an intervention aimed at improving VMMC standards adherence and patient follow-up rates in nine ...

  16. Standard test of labelling efficiency for quality control of no carrier added 90YCl3

    International Nuclear Information System (INIS)

    Beran, M.; Eigner Henke, K.; Srank, J.; Melichar, F.

    2007-01-01

    Particle emitting radionuclides (e.g. beta-emitters 90 Y and 177 Lu, alpha-emitter 211 At, Auger electron emitter 165 Er or positron emitter 86 Y) are beeing more and more frequently used in research and clinical practice for imaging and targeted therapy in nuclear medicine. This radiometals, altogether three valent lanthanides or actinides with high specific radioactivity, coupled to biomolecule carriers (peptides or monoclonal antibodies) through chelating link (e.g. DTPA or DOTA) are targeted against specific antigens and receptors of diseased tissues in order to obtain their image or to cause their radiation ablation. The radionuclide precursor 90 YCl 3 (solution of hard β-emitter 90 Y in a diluted HCl) with high purity and specific activity is already commercially produced and successfully used in nuclear medicine, e.g. for radioimmunotherapy of Lymphoma. Specification and purity of our product obtained by extraction 90 Sr/ 90 Y generator (using technology of centrifuge extractors with di-2-ethylhexylphosphoric acid) is examined and compared to other similar products in this contribution. A standard method for determination of labelling efficiency of the precursor with DOTA Octreotide (DOTATATE) using ITLC/SG chromatography is also described and proposed for quality assesment. (Author)

  17. A global standardization trend for high-speed client and line side transceivers

    Science.gov (United States)

    Isono, Hideki

    2015-03-01

    Seeing the recent vast data increase in information industry, IT society will move into the new era of Zettabyte in a few years. Under these circumstances, high-speed and high-capacity optical communication systems have been deployed in the industry. Especially high speed optical transceivers are key devices to realize high-speed systems, and the practical development is accelerated. In order to develop these leading edge products timely, the global standard criteria are strongly required in the industry. Based on these backgrounds, the forum standardization bodies such as OIF PLLWG/ IEEE802.3 are energetically creating the de-fact standards. With regard to 100G/400G standardization activities, IEEE802.3 leads the client side, and OIF PLL-WG leads the line side, and both of them play important roles in the industry. In the previous Photonics West conferences, the activities of these standardization bodies till 2013 were reported. In 2014, the discussions of 400G client side transceiver projects have made some progress in IEEE802.3, whose baseline technologies are about to be fixed. Also 100G transceiver projects for metro applications in the line side, whose target profile is CFP2 form factor, have been discussed in OIF PLL-WG. In this paper, these high-end standardization topics are introduced and the future products direction is also discussed from the technical point of view. In order to realize these small form factor and cost effective transceivers, the device integration technologies, the low power device/electrical circuit technologies, and the development of high speed electrical interface such as 25G/50G are key factors.

  18. 6. Seminar of the IIE-ININ-IMP on technological specialties. Topic 11: standards and quality assurance

    International Nuclear Information System (INIS)

    1992-01-01

    The document includes 8 papers presented at the 6. Seminar of the IIE-ININ-IMP (Mexico) on technological specialties in the field of standards and quality assurance. (Topic 11). From these, 2 papers were in INIS subject scope and a separate abstract was prepared for each of them

  19. Synergy among School and District Leaders in the Application of Quality Standards in Kuwaiti Public Schools

    Science.gov (United States)

    Aldaihani, Sultan Ghaleb

    2017-01-01

    This study sought to identify existing levels of synergy, or cooperation and compatibility, among school and district leaders and the impact of synergy on standards of quality in Kuwaiti schools. The researcher employed a qualitative methodology based on interviews with principals and administrators representing the six educational districts in…

  20. Image Quality in High-resolution and High-cadence Solar Imaging

    Science.gov (United States)

    Denker, C.; Dineva, E.; Balthasar, H.; Verma, M.; Kuckein, C.; Diercke, A.; González Manrique, S. J.

    2018-03-01

    Broad-band imaging and even imaging with a moderate bandpass (about 1 nm) provides a photon-rich environment, where frame selection (lucky imaging) becomes a helpful tool in image restoration, allowing us to perform a cost-benefit analysis on how to design observing sequences for imaging with high spatial resolution in combination with real-time correction provided by an adaptive optics (AO) system. This study presents high-cadence (160 Hz) G-band and blue continuum image sequences obtained with the High-resolution Fast Imager (HiFI) at the 1.5-meter GREGOR solar telescope, where the speckle-masking technique is used to restore images with nearly diffraction-limited resolution. The HiFI employs two synchronized large-format and high-cadence sCMOS detectors. The median filter gradient similarity (MFGS) image-quality metric is applied, among others, to AO-corrected image sequences of a pore and a small sunspot observed on 2017 June 4 and 5. A small region of interest, which was selected for fast-imaging performance, covered these contrast-rich features and their neighborhood, which were part of Active Region NOAA 12661. Modifications of the MFGS algorithm uncover the field- and structure-dependency of this image-quality metric. However, MFGS still remains a good choice for determining image quality without a priori knowledge, which is an important characteristic when classifying the huge number of high-resolution images contained in data archives. In addition, this investigation demonstrates that a fast cadence and millisecond exposure times are still insufficient to reach the coherence time of daytime seeing. Nonetheless, the analysis shows that data acquisition rates exceeding 50 Hz are required to capture a substantial fraction of the best seeing moments, significantly boosting the performance of post-facto image restoration.

  1. 76 FR 54293 - Review of National Ambient Air Quality Standards for Carbon Monoxide

    Science.gov (United States)

    2011-08-31

    ...), hypertension (high blood pressure), and peripheral vascular diseases. Heart disease, in turn, comprises several... further concludes that no secondary standard should be set for CO at this time. EPA is also making changes.... Consideration of a Secondary Standard A. Introduction B. Rationale for Proposed Decision C. Comments on...

  2. PROCEDURE FOR ANALYSIS COMPLIANCE WITH QUALITY STANDARDS OFFER OF THE BUFFET RESTAURANT CASONA MELIA SANTIAGO DE CUBA

    Directory of Open Access Journals (Sweden)

    Oscar Parada-Pérez

    2016-01-01

    Full Text Available The company hotel Cuban faces the challenge of the competitiveness and the client’s satisfaction in an environment that demands of actions that they assure the quality. This article has as objective to show the application of a procedure for the evaluation of the standards of quality of the offer in the restaurant buffet La Casona of the Hotel Meliá Santiago de Cuba. The results achieved by the application of the procedure allow to perfect the process of taking of decisions and it contributes to the efficiency of the hotel and the elevation of the quality of the service. 

  3. Causes for variation in pork quality

    NARCIS (Netherlands)

    Wal, van der P.; Engel, B.; Hulsegge, B.

    1997-01-01

    Research was carried out on 260 pigs that were slaughtered in 12 batches in the slaughter facilities of ID-DLO at Zeist. The practical circumstances were highly standardized. The 'animals' meat quality was good with only little variation; 46 animals showed a 'slightly' aberrant quality and 6

  4. Implementation of the OECD principles of good laboratory practice in test facilities complying with a quality system accredited to the ISO/IEC 17025 standard.

    Science.gov (United States)

    Feller, Etty

    2008-01-01

    Laboratories with a quality system accredited to the ISO/IEC 17025 standard have a definite advantage, compared to non-accredited laboratories, when preparing their facilities for the implementation of the principles of good laboratory practice (GLP) of the Organisation for Economic Co-operation and Development (OECD). Accredited laboratories have an established quality system covering the administrative and technical issues specified in the standard. The similarities and differences between the ISO/IEC 17025 standard and the OECD principles of GLP are compared and discussed.

  5. Management system - correlation study between new IAEA standards and the market standards

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Dirceu Paulo de [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Ipero, SP (Brazil)], e-mail: dirceupo@hotmail.com; Zouain, Desiree Moraes [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: dmzouain@ipen.br

    2009-07-01

    In order to answer the growing concern of society with respect of the aspects that affect the quality of life, international and national regulatory bodies have developed standards that enable organizations to establish management systems for quality, environment and sustainable development, health, safety and social responsibility, among other functions. Within this context it is necessary to structure an integrated management system that promotes interests compatibility of several distinct and complementary functions involved. Considering this vision of the management system integration, the International Atomic Energy Agency (IAEA) decided to review the structure of safety standards on Quality Assurance - code and guides 50-C/SGQ1/ 14:1996, publishing, in 2006, IAEA GS-R-3 and IAEA GS-G-3.1 standards, enlarging the management approach of the previous standards, including the possibility of integrating the functions foremost mentioned. This paper presents the results about a correlation study between IAEA management system standards - IAEA GS-R-3: 2006, IAEA GS-G-3.1: 2006 and IAEA DS349 rev. 2007, this latter still a draft standard, with those market management system standards on quality - ISO 9001:2008, environmental - ISO 14001:2004, and occupational health and safety - BS OHSAS 18001:2007, identifying gaps, redundancies and complementarities among their requirements and guidances. The purpose of the study is to provide subsidies that could contribute to the structuring of a management system to nuclear facilities that satisfies, in an integrated manner, the common and complementary requirements and guidances of IAEA and market standards. (author)

  6. Management system - correlation study between new IAEA standards and the market standards

    International Nuclear Information System (INIS)

    Oliveira, Dirceu Paulo de; Zouain, Desiree Moraes

    2009-01-01

    In order to answer the growing concern of society with respect of the aspects that affect the quality of life, international and national regulatory bodies have developed standards that enable organizations to establish management systems for quality, environment and sustainable development, health, safety and social responsibility, among other functions. Within this context it is necessary to structure an integrated management system that promotes interests compatibility of several distinct and complementary functions involved. Considering this vision of the management system integration, the International Atomic Energy Agency (IAEA) decided to review the structure of safety standards on Quality Assurance - code and guides 50-C/SGQ1/ 14:1996, publishing, in 2006, IAEA GS-R-3 and IAEA GS-G-3.1 standards, enlarging the management approach of the previous standards, including the possibility of integrating the functions foremost mentioned. This paper presents the results about a correlation study between IAEA management system standards - IAEA GS-R-3: 2006, IAEA GS-G-3.1: 2006 and IAEA DS349 rev. 2007, this latter still a draft standard, with those market management system standards on quality - ISO 9001:2008, environmental - ISO 14001:2004, and occupational health and safety - BS OHSAS 18001:2007, identifying gaps, redundancies and complementarities among their requirements and guidances. The purpose of the study is to provide subsidies that could contribute to the structuring of a management system to nuclear facilities that satisfies, in an integrated manner, the common and complementary requirements and guidances of IAEA and market standards. (author)

  7. Standard operating procedures for quality audits of 60Co external beam radiotherapy facilities

    International Nuclear Information System (INIS)

    Larrinaga Cortina, E.F.; Dominguez Hung, L.; Campa Menendez, R.

    2001-01-01

    The use of radiotherapy implies the necessity of rigorous quality standards in its different components, aimed to provide the best possible treatment and avoid potential patients' risks, that could even cause him death. Projects of technical cooperation developed in Cuba and supported by the International Atomic Energy Agency address the implementation of Programs of Quality Assurance (PGC) in radiotherapy services. The establishment of the National Quality Audit Program (PNAC) is a superior stage. The National Control Center for Medical Devices, as the national regulator entity for the control and supervision of medical devices in the National Health System, is responsible for the making and execution of the PNAC. The audit modality selected was the inspection visit in situ due to its intrinsic advantages, our geographical extension and the number of radiotherapy services. This paper presents the methodology for the execution of the PNAC, in form of a Normalized Procedure of Operation (PNO) that defines the objectives, scope, terms and definitions, responsibilities, composition and selection of the auditor team, security's conditions, materials and equipment, steps of the audit execution, results calculation and interpretation, records, etc. (author)

  8. The standard of spirometry in the RSA | Basson | South African ...

    African Journals Online (AJOL)

    Standards for high-quality lung function testing have not yet been formally adopted in the RSA, despite the increase in the performance of spirometry. A study was undertaken to determine the standard of spirometry in clinical practice in this country. Forty-five spirometer users agreed to participate. Responses to a ...

  9. Promoting Quality in Education. Schools Can Use Total Quality Management Concepts to Boost Student Performance.

    Science.gov (United States)

    Schargel, Franklin P.

    1991-01-01

    Schools must establish the same quality standards and techniques used by businesses to achieve Total Quality Management (TMQ). TMQ can help public education to respond to the challenges typical of inner-city schools: a high transfer rate; aging faculty; and students with poor reading and math skills, lack of motivation, low self-esteem, and a…

  10. Standardized high current solid targets for cyclotron production of radionuclides

    International Nuclear Information System (INIS)

    Al-Jammaz, Ibrahim

    2000-01-01

    The Cyclotron and Radiopharmaceuticals Department (CRP) is an advanced and modern facility that encompasses two essential components: radioisotope research, and radiopharmaceuticals manufacturing. Radiopharmaceuticals manufacturing program is not only quite unique, but also an essential component of King Faisal Specialist Hospital and Research Center (KFSH and RC) in providing quality patient care for the population of the Kingdom. Accurate diagnosis and therapy with medical imaging equipment requires quality radiopharmaceuticals that are available readily and with reliability. The CRP Department provides that quality and reliability. Research activities of the CRP Department are focused on developing new radiotracers with potential usefulness in biomedical research and clinical applications. Research projects consist of: developing cyclotron targetry for radioisotope production; developing synthesis methods for radiolabeling biomolecules; and developing analytical methods for quality control. The CRP Department operates a semi-commercial radiopharmaceuticals manufacturing program that supplies the diagnostic radioactive products to several hospitals in the Kingdom and neighboring countries. These products for clinical applications are produced according to the international standards of Good Manufacturing Practices of quality and efficacy. At the heart of the radioisotope program is a medium energy cyclotron capable of accelerating a number of particles for transformation of non-radioactive atoms into radionuclides that are the primary sources for research and development activities, and for preparing radiopharmaceuticals. In addition to having the only cyclotron facility in the region, KFSH and RC also has the only Positron Emission Tomography Center (PET) in this part of the world. This combination of cyclotron and the ultra modern PET facility translates into advanced and specialized care for the patients at KFSH and RC

  11. New standard environmental management

    International Nuclear Information System (INIS)

    Andriola, Luca; Luciani, Roberto

    2006-01-01

    The ISO 14001:2004 standard, like ISO 9001:2000 on quality management, transcends the preventive approach (based on a rigid and more or less adequate process-management model still mainly inspired by traditional production methods) and introduces in its stead a highly flexible approach applicable to any socio-economic activity. It is structured by processes rather than system elements, and is based on the quest for efficacy and ongoing improvement [it

  12. High-quality remote interactive imaging in the operating theatre

    Science.gov (United States)

    Grimstead, Ian J.; Avis, Nick J.; Evans, Peter L.; Bocca, Alan

    2009-02-01

    We present a high-quality display system that enables the remote access within an operating theatre of high-end medical imaging and surgical planning software. Currently, surgeons often use printouts from such software for reference during surgery; our system enables surgeons to access and review patient data in a sterile environment, viewing real-time renderings of MRI & CT data as required. Once calibrated, our system displays shades of grey in Operating Room lighting conditions (removing any gamma correction artefacts). Our system does not require any expensive display hardware, is unobtrusive to the remote workstation and works with any application without requiring additional software licenses. To extend the native 256 levels of grey supported by a standard LCD monitor, we have used the concept of "PseudoGrey" where slightly off-white shades of grey are used to extend the intensity range from 256 to 1,785 shades of grey. Remote access is facilitated by a customized version of UltraVNC, which corrects remote shades of grey for display in the Operating Room. The system is successfully deployed at Morriston Hospital, Swansea, UK, and is in daily use during Maxillofacial surgery. More formal user trials and quantitative assessments are being planned for the future.

  13. Determination and validation of soil thresholds for cadmium based on food quality standard and health risk assessment.

    Science.gov (United States)

    Ding, Changfeng; Ma, Yibing; Li, Xiaogang; Zhang, Taolin; Wang, Xingxiang

    2018-04-01

    Cadmium (Cd) is an environmental toxicant with high rates of soil-plant transfer. It is essential to establish an accurate soil threshold for the implementation of soil management practices. This study takes root vegetable as an example to derive soil thresholds for Cd based on the food quality standard as well as health risk assessment using species sensitivity distribution (SSD). A soil type-specific bioconcentration factor (BCF, ratio of Cd concentration in plant to that in soil) generated from soil with a proper Cd concentration gradient was calculated and applied in the derivation of soil thresholds instead of a generic BCF value to minimize the uncertainty. The sensitivity variations of twelve root vegetable cultivars for accumulating soil Cd and the empirical soil-plant transfer model were investigated and developed in greenhouse experiments. After normalization, the hazardous concentrations from the fifth percentile of the distribution based on added Cd (HC5 add ) were calculated from the SSD curves fitted by Burr Type III distribution. The derived soil thresholds were presented as continuous or scenario criteria depending on the combination of soil pH and organic carbon content. The soil thresholds based on food quality standard were on average 0.7-fold of those based on health risk assessment, and were further validated to be reliable using independent data from field survey and published articles. The results suggested that deriving soil thresholds for Cd using SSD method is robust and also applicable to other crops as well as other trace elements that have the potential to cause health risk issues. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  15. Real-World Solutions for Developing High-Quality PHP Frameworks and Applications

    CERN Document Server

    Bergmann, Sebastian

    2011-01-01

    Learn to develop high-quality applications and frameworks in PHP Packed with in-depth information and step-by-step guidance, this book escorts you through the process of creating, maintaining and extending sustainable software of high quality with PHP. World-renowned PHP experts present real-world case studies for developing high-quality applications and frameworks in PHP that can easily be adapted to changing business requirements. . They offer different approaches to solving  typical development and quality assurance problems that every developer needs to know and master.Details the process

  16. Professional Standards for Visual Arts Educators

    Science.gov (United States)

    National Art Education Association, 2009

    2009-01-01

    The National Art Education Association (NAEA) is committed to ensuring that all students have access to a high quality, certified visual arts educator in every K-12 public school across the United States, recognizing that effective arts instruction is a core component of 21st-century education. "Professional Standards for Visual Arts…

  17. 40 CFR 50.11 - National primary and secondary ambient air quality standards for oxides of nitrogen (with...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false National primary and secondary ambient air quality standards for oxides of nitrogen (with nitrogen dioxide as the indicator). 50.11 Section 50.11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL...

  18. Multi-line split DNA synthesis: a novel combinatorial method to make high quality peptide libraries

    Directory of Open Access Journals (Sweden)

    Ueno Shingo

    2004-09-01

    Full Text Available Abstract Background We developed a method to make a various high quality random peptide libraries for evolutionary protein engineering based on a combinatorial DNA synthesis. Results A split synthesis in codon units was performed with mixtures of bases optimally designed by using a Genetic Algorithm program. It required only standard DNA synthetic reagents and standard DNA synthesizers in three lines. This multi-line split DNA synthesis (MLSDS is simply realized by adding a mix-and-split process to normal DNA synthesis protocol. Superiority of MLSDS method over other methods was shown. We demonstrated the synthesis of oligonucleotide libraries with 1016 diversity, and the construction of a library with random sequence coding 120 amino acids containing few stop codons. Conclusions Owing to the flexibility of the MLSDS method, it will be able to design various "rational" libraries by using bioinformatics databases.

  19. Using Quality Management Systems to Improve Test Development and Standards and to Promote Good Practice: A Case Study of Testing Italian as a Foreign Language

    Science.gov (United States)

    Grego Bolli, Giuliana

    2014-01-01

    This article discusses the problem of quality in the production of language tests in the context of Italian language examinations. The concept of quality is closely related to the application of stated standards and related procedures. These standards, developed over the last thirty years, are mainly related to the concepts of the accountability…

  20. Draft of standard for graphite core components in high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Shibata, Taiju; Sawa, Kazuhiro; Eto, Motokuni; Kunimoto, Eiji; Shiozawa, Shusaku; Oku, Tatsuo; Maruyama, Tadashi

    2010-01-01

    For the design of the graphite components in the High Temperature Engineering Test Reactor (HTTR), the graphite structural design code for the HTTR etc. were applied. However, general standard systems for the High Temperature Gas-cooled Reactor (HTGR) have not been established yet. The authors had studied on the technical issues which is necessary for the establishment of a general standard system for the graphite components in the HTGR. The results of the study were documented and discussed at a 'Special committee on research on preparation for codes for graphite components in HTGR' at Atomic Energy Society of Japan (AESJ). As a result, 'Draft of Standard for Graphite Core Components in High Temperature Gas-cooled Reactor.' was established. In the draft standard, the graphite components are classified three categories (A, B and C) in the standpoints of safety functions and possibility of replacement. For the components in the each class, design standard, material and product standards, and in-service inspection and maintenance standard are determined. As an appendix of the design standard, the graphical expressions of material property data of 1G-110 graphite as a function of fast neutron fluence are expressed. The graphical expressions were determined through the interpolation and extrapolation of the irradiated data. (author)

  1. New approaches for the standardization and validation of a real-time qPCR assay using TaqMan probes for quantification of yellow fever virus on clinical samples with high quality parameters.

    Science.gov (United States)

    Fernandes-Monteiro, Alice G; Trindade, Gisela F; Yamamura, Anna M Y; Moreira, Otacilio C; de Paula, Vanessa S; Duarte, Ana Cláudia M; Britto, Constança; Lima, Sheila Maria B

    2015-01-01

    The development and production of viral vaccines, in general, involve several steps that need the monitoring of viral load throughout the entire process. Applying a 2-step quantitative reverse transcription real time PCR assay (RT-qPCR), viral load can be measured and monitored in a few hours. In this context, the development, standardization and validation of a RT-qPCR test to quickly and efficiently quantify yellow fever virus (YFV) in all stages of vaccine production are extremely important. To serve this purpose we used a plasmid construction containing the NS5 region from 17DD YFV to generate the standard curve and to evaluate parameters such as linearity, precision and specificity against other flavivirus. Furthermore, we defined the limits of detection as 25 copies/reaction, and quantification as 100 copies/reaction for the test. To ensure the quality of the method, reference controls were established in order to avoid false negative results. The qRT-PCR technique based on the use of TaqMan probes herein standardized proved to be effective for determining yellow fever viral load both in vivo and in vitro, thus becoming a very important tool to assure the quality control for vaccine production and evaluation of viremia after vaccination or YF disease.

  2. Wavelet/scalar quantization compression standard for fingerprint images

    Energy Technology Data Exchange (ETDEWEB)

    Brislawn, C.M.

    1996-06-12

    US Federal Bureau of Investigation (FBI) has recently formulated a national standard for digitization and compression of gray-scale fingerprint images. Fingerprints are scanned at a spatial resolution of 500 dots per inch, with 8 bits of gray-scale resolution. The compression algorithm for the resulting digital images is based on adaptive uniform scalar quantization of a discrete wavelet transform subband decomposition (wavelet/scalar quantization method). The FBI standard produces archival-quality images at compression ratios of around 15 to 1 and will allow the current database of paper fingerprint cards to be replaced by digital imagery. The compression standard specifies a class of potential encoders and a universal decoder with sufficient generality to reconstruct compressed images produced by any compliant encoder, allowing flexibility for future improvements in encoder technology. A compliance testing program is also being implemented to ensure high standards of image quality and interchangeability of data between different implementations.

  3. Coaching individuals with perfectionistic tendencies When high standards help and hinder

    Directory of Open Access Journals (Sweden)

    Sarah Corrie

    2014-07-01

    Full Text Available Perfectionism has been widely recognised in the clinical field but has received less attention in the coaching psychology literature. Referring to overly high and unforgiving personal standards of performance that are accompanied by harsh self-evaluation when self-imposed standards are not met, perfectionism has the potential to undermine the coachee’s ability to achieve their goals as well as the coaching process itself. In consequence, it is important for practitioners to be able to identify and work effectively with those coachees whose perfectionistic tendencies represent an obstacle to progress. This paper discusses the current literature on perfectionism and provides recommendations on how to work effectively with coachees for whom unremittingly high personal standards are an impediment to personal growth and development.

  4. Monitoring maternal and newborn health outcomes in Bauchi State, Nigeria: an evaluation of a standards-based quality improvement intervention.

    Science.gov (United States)

    Kabo, Ibrahim; Otolorin, Emmanuel; Williams, Emma; Orobaton, Nosa; Abdullahi, Hannatu; Sadauki, Habib; Abdulkarim, Masduk; Abegunde, Dele

    2016-10-01

    This study assessed the correlation between compliance with set performance standards and maternal and neonatal deaths in health facilities. Baseline and three annual follow-up assessments were conducted, and each was followed by a quality improvement initiative using the Standards Based Management and Recognition (SBM-R) approach. Twenty-three secondary health facilities of Bauchi state, Nigeria. Health care workers and maternity unit patients. We examined trends in: (i) achievement of SBM-R set performance standards based on annual assessment data, (ii) the use of maternal and newborn health (MNH) service delivery practices based on data from health facility registers and supportive supervision and (iii) MNH outcomes based on routine service statistics. At the baseline assessment in 2010, the facilities achieved 4% of SBM-R standards for MNH, on average, and this increased to 86% in 2013. Over the same time period, the study measured an increase in the administration of uterotonic for active management of third stage of labor from 10% to 95% and a decline in the incidence of postpartum hemorrhage from 3.3% to 1.9%. Institutional neonatal mortality rate decreased from 9 to 2 deaths per 1000 live births, while the institutional maternal mortality ratio dropped from 4113 to 1317 deaths per 100 000 live births. Scaling up SBM-R for quality improvement has the potential to prevent maternal and neonatal deaths in Nigeria and similar settings. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care.

  5. Quality control of commercial bovine lactoferrin.

    Science.gov (United States)

    Wakabayashi, Hiroyuki; Yamauchi, Koji; Abe, Fumiaki

    2018-06-01

    Herein we review commercial bovine lactoferrin quality issues by describing an example of industrial production, the current status of global quality standardization, and quality-activity concerns for further discussion. Morinaga Milk Industry has been industrially producing bovine lactoferrin in Milei GmbH, Germany, since 1989. We delineate its production and quality as an example of safe and high-quality manufacturing. Currently, global standardization in the quality of bovine lactoferrin is progressing through Novel Food and GRAS in the EU and USA, respectively. Novel Food was applied or notified to seven lactoferrin manufacturers and GRAS was notified to three manufacturers, two of which are for infant use and one is for adult use, by the end of 2017. The specifications of these regulations are relatively high, including more than 95% lactoferrin purity in protein, which means that such companies can supply relatively high-grade lactoferrin. There appear to be several concerns regarding lactoferrin quality affecting activities, including contamination of lipopolysaccharide (LPS) and angiogenin, purity, and degradation of lactoferrin sample. Although LPS is immunologically toxic when invading the body, it is distributed normally in foods and the gut. However, an industrial lactoferrin sample may contain LPS at a maximum LPS/lactoferrin molecule ratio = 1/1724, which means 99.9% of the lactoferrin molecule is LPS-free. It is difficult to speculate that LPS contained in a lactoferrin sample affects its activities. Finally in order to achieve good and reproducible results, we make proposals to researchers a use of high-grade lactoferrin, careful storage, and indication the manufacturers' names and specifications in the paper.

  6. Quality assessment of Chrysanthemum indicum Flower by simultaneous quantification of six major ingredients using a single reference standard combined with HPLC fingerprint analysis

    Directory of Open Access Journals (Sweden)

    Jiao He

    2016-04-01

    Full Text Available Chrysanthemum indicum Flower is usually consumed as functional food. This paper described an improved total quality assessment method for Chrysanthemum indicum Flower by simultaneous quantitation using a single standard to determine multi-components method combined with high performance liquid chromatography fingerprint analysis. Six main components of Chrysanthemum indicum Flower including two flavonoids and four phenolic acids were simultaneously quantified using linarin as the internal reference standard. The method was fully validated with respect to linearity, precision, accuracy, robustness and stability. The validated method was successfully applied to the analysis of thirty three batches of Chrysanthemum indicum Flower samples. Under the same chromatographic conditions, fingerprint analysis in combination with Similarity analysis and principal component analysis was performed to identify the samples from different regions. In general, an effective assessment using a single standard to determinate multi-components method combined with fingerprint analysis make the reliable qualitation and quantitation analysis of Chrysanthemum indicum Flower available.

  7. A standard-driven implementaion of WS-BPEL 2.0

    DEFF Research Database (Denmark)

    Hallwyl, Tim; Henglein, Fritz; Hildebrandt, Thomas

    2010-01-01

    We present a systematic study of the WS-BPEL 2.0 standard based on two complementary methods: the process of constructing a new high-level WS-BPEL implementation driven by the structure of the standard, and an empirical evaluation of existing interpretations of the standard reflected in five widely...... differing results produced by existing implementations on test cases constructed to exercise their interpretation. The core concepts in WS-BPEL have been formalized and analyzed successfully previously. Our choice to study the standard by constructing a high-level, standard-driven implementation rather than...... an abstract, mathematical formalization has made it feasible to cover the complete standard, notably the integration with XPath. Given WS-BPEL's design goal of being platform-independent the inconsistencies are arguably a serious concern since they cannot be attributed to the quality of any particular...

  8. Blueprint for action: steps toward a high-quality, high-value maternity care system.

    Science.gov (United States)

    Angood, Peter B; Armstrong, Elizabeth Mitchell; Ashton, Diane; Burstin, Helen; Corry, Maureen P; Delbanco, Suzanne F; Fildes, Barbara; Fox, Daniel M; Gluck, Paul A; Gullo, Sue Leavitt; Howes, Joanne; Jolivet, R Rima; Laube, Douglas W; Lynne, Donna; Main, Elliott; Markus, Anne Rossier; Mayberry, Linda; Mitchell, Lynn V; Ness, Debra L; Nuzum, Rachel; Quinlan, Jeffrey D; Sakala, Carol; Salganicoff, Alina

    2010-01-01

    Childbirth Connection hosted a 90th Anniversary national policy symposium, Transforming Maternity Care: A High Value Proposition, on April 3, 2009, in Washington, DC. Over 100 leaders from across the range of stakeholder perspectives were actively engaged in the symposium work to improve the quality and value of U.S. maternity care through broad system improvement. A multi-disciplinary symposium steering committee guided the strategy from its inception and contributed to every phase of the project. The "Blueprint for Action: Steps Toward a High Quality, High Value Maternity Care System", issued by the Transforming Maternity Care Symposium Steering Committee, answers the fundamental question, "Who needs to do what, to, for, and with whom to improve the quality of maternity care over the next five years?" Five stakeholder workgroups collaborated to propose actionable strategies in 11 critical focus areas for moving expeditiously toward the realization of the long term "2020 Vision for a High Quality, High Value Maternity Care System", also published in this issue. Following the symposium these workgroup reports and recommendations were synthesized into the current blueprint. For each critical focus area, the "Blueprint for Action" presents a brief problem statement, a set of system goals for improvement in that area, and major recommendations with proposed action steps to achieve them. This process created a clear sightline to action that if enacted could improve the structure, process, experiences of care, and outcomes of the maternity care system in ways that when anchored in the culture can indeed transform maternity care. Copyright 2010 Jacobs Institute of Women

  9. Improved entropy encoding for high efficient video coding standard

    Directory of Open Access Journals (Sweden)

    B.S. Sunil Kumar

    2018-03-01

    Full Text Available The High Efficiency Video Coding (HEVC has better coding efficiency, but the encoding performance has to be improved to meet the growing multimedia applications. This paper improves the standard entropy encoding by introducing the optimized weighing parameters, so that higher rate of compression can be accomplished over the standard entropy encoding. The optimization is performed using the recently introduced firefly algorithm. The experimentation is carried out using eight benchmark video sequences and the PSNR for varying rate of data transmission is investigated. Comparative analysis based on the performance statistics is made with the standard entropy encoding. From the obtained results, it is clear that the originality of the decoded video sequence is preserved far better than the proposed method, though the compression rate is increased. Keywords: Entropy, Encoding, HEVC, PSNR, Compression

  10. Standard practice for determining relative image quality response of industrial radiographic imaging systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This standard provides a practice whereby industrial radiographic imaging systems may be comparatively assessed using the concept of relative image quality response (RIQR). The RIQR method presented within this practice is based upon the use of equivalent penetrameter sensitivity (EPS) described within Practice E 1025 and subsection 5.2 of this practice. Figure 1 illustrates a relative image quality indicator (RIQI) that has four different steel plaque thicknesses (.015, .010, .008, and .005 in.) sequentially positioned (from top to bottom) on a ¾-in. thick steel plate. The four plaques contain a total of 14 different arrays of penetrameter-type hole sizes designed to render varied conditions of threshold visibility ranging from 1.92 % EPS (at the top) to .94 % EPS (at the bottom) when exposed to nominal 200 keV X-ray radiation. Each “EPS” array consists of 30 identical holes; thus, providing the user with a quantity of threshold sensitivity levels suitable for relative image qualitative response com...

  11. Evaluation of the Beam Quality of Intraoral X-ray Equipment using Intraoral Standard Films

    International Nuclear Information System (INIS)

    Lee, Sang Sub; Kwon, Hyok Rak; Sim, Woo Hyoun; Oh, Seung Hyoun; Lee, Ji Youn; Jeon, Kug Jin; Kim, Kee Deog; Park, Chang Seo

    2000-01-01

    This study was to evaluate the beam quality of intraoral X-ray equipment used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. The study was done using the intraoral X-ray equipment used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Most of the HVLs of intraoral X-ray equipment were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANPAS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X-ray equipment should be managed in the planned and organized fashion.

  12. High-rise construction in Russia as one of the objectives of improving the management mechanism for living standards of the population

    Science.gov (United States)

    Sergeeva, Svetlana; Komyshova, Lyudmila; Nagibina, Natalia

    2018-03-01

    The article is aimed at determining the significance of solving the problem of high-rise construction in Russia as one of the tasks of improving the mechanism of managing the living standards of the population. To determine the effectiveness of measures aimed at improving the quality of life management mechanism, the expert evaluation method is used. The paper presents the measures to improve the quality of life and consequently the migration attractiveness of the region. Despite a number of actual difficulties and lack of sufficient experience, there is an interest in the development of high-rise construction. The result of the analysis of the general demographic dynamics for the last fifteen years is shown. Migration is the most mobile tool for managing short-term demographic processes; therefore, great attention should be paid to this component. Moreover, it is necessary to take into account other consequences of migration.

  13. Feasibility of establishing a biosafety level 3 tuberculosis culture laboratory of acceptable quality standards in a resource-limited setting: an experience from Uganda.

    Science.gov (United States)

    Ssengooba, Willy; Gelderbloem, Sebastian J; Mboowa, Gerald; Wajja, Anne; Namaganda, Carolyn; Musoke, Philippa; Mayanja-Kizza, Harriet; Joloba, Moses Lutaakome

    2015-01-15

    Despite the recent innovations in tuberculosis (TB) and multi-drug resistant TB (MDR-TB) diagnosis, culture remains vital for difficult-to-diagnose patients, baseline and end-point determination for novel vaccines and drug trials. Herein, we share our experience of establishing a BSL-3 culture facility in Uganda as well as 3-years performance indicators and post-TB vaccine trials (pioneer) and funding experience of sustaining such a facility. Between September 2008 and April 2009, the laboratory was set-up with financial support from external partners. After an initial procedure validation phase in parallel with the National TB Reference Laboratory (NTRL) and legal approvals, the laboratory registered for external quality assessment (EQA) from the NTRL, WHO, National Health Laboratories Services (NHLS), and the College of American Pathologists (CAP). The laboratory also instituted a functional quality management system (QMS). Pioneer funding ended in 2012 and the laboratory remained in self-sustainability mode. The laboratory achieved internationally acceptable standards in both structural and biosafety requirements. Of the 14 patient samples analyzed in the procedural validation phase, agreement for all tests with NTRL was 90% (P 80% in all years from NTRL, CAP, and NHLS, and culture was 100% for CAP panels and above regional average scores for all years with NHLS. Quarterly DST scores from WHO-EQA ranged from 78% to 100% in 2010, 80% to 100% in 2011, and 90 to 100% in 2012. From our experience, it is feasible to set-up a BSL-3 TB culture laboratory with acceptable quality performance standards in resource-limited countries. With the demonstrated quality of work, the laboratory attracted more research groups and post-pioneer funding, which helped to ensure sustainability. The high skilled experts in this research laboratory also continue to provide an excellent resource for the needed national discussion of the laboratory and quality management systems.

  14. Estimating the Pollution Risk of Cadmium in Soil Using a Composite Soil Environmental Quality Standard

    Science.gov (United States)

    Huang, Biao; Zhao, Yongcun

    2014-01-01

    Estimating standard-exceeding probabilities of toxic metals in soil is crucial for environmental evaluation. Because soil pH and land use types have strong effects on the bioavailability of trace metals in soil, they were taken into account by some environmental protection agencies in making composite soil environmental quality standards (SEQSs) that contain multiple metal thresholds under different pH and land use conditions. This study proposed a method for estimating the standard-exceeding probability map of soil cadmium using a composite SEQS. The spatial variability and uncertainty of soil pH and site-specific land use type were incorporated through simulated realizations by sequential Gaussian simulation. A case study was conducted using a sample data set from a 150 km2 area in Wuhan City and the composite SEQS for cadmium, recently set by the State Environmental Protection Administration of China. The method may be useful for evaluating the pollution risks of trace metals in soil with composite SEQSs. PMID:24672364

  15. [Management of quality in an Intensive Care Unit: implementation of ISO 9001:2008 international standard].

    Science.gov (United States)

    Lorenzo Torrent, R; Sánchez Palacios, M; Santana Cabrera, L; Cobian Martinez, J L; García del Rosario, C

    2010-10-01

    The Quality Management Systems make it possible to prioritize actions to maintain the safety and efficacy of health technologies. The Intensive Care Unit of our hospital has implemented a quality management plan, which has obtained accreditation as "Service Certificate that manages its activities according to UNE-EN ISO 9001:2008" standard. With the application of quality management system, it has been possible to detect the needs that the Service can cover in order to obtain the satisfaction of the patient, relative or health personnel of the other services of the hospital, to improve communications inside and outside of service, to secure greater understanding of the processes of the organization and control of risk, to delimit responsibilities clearly to all the personnel, to make better use of the time and resources and, finally, to improve the motivation of the personnel. Copyright © 2009 Elsevier España, S.L. y SEMICYUC. All rights reserved.

  16. Evaluating the U.S. Food Safety Modernization Act Produce Safety Rule Standard for Microbial Quality of Agricultural Water for Growing Produce

    NARCIS (Netherlands)

    Havelaar, Arie H; Vazquez, Kathleen M; Topalcengiz, Zeynal; Muñoz-Carpena, Rafael; Danyluk, Michelle D

    2017-01-01

    The U.S. Food and Drug Administration (FDA) has defined standards for the microbial quality of agricultural surface water used for irrigation. According to the FDA produce safety rule (PSR), a microbial water quality profile requires analysis of a minimum of 20 samples for Escherichia coli over 2 to

  17. Consumer Quality Index Chronic Skin Disease (CQI-CSD): a new instrument to measure quality of care from the patient's perspective

    NARCIS (Netherlands)

    van Cranenburgh, O. D.; Krol, M. W.; Hendriks, M. C. P.; de Rie, M. A.; Smets, E. M. A.; de Korte, J.; Sprangers, M. A. G.

    2015-01-01

    Assessing quality of care from the patient's perspective is considered to be highly relevant. As a standardized instrument in dermatology was lacking, we developed a patient experience questionnaire regarding chronic skin disease care: the Consumer Quality Index Chronic Skin Disease (CQI-CSD). (i)

  18. Adoption and impact of high quality bambara flour (HQBF ...

    African Journals Online (AJOL)

    Adoption and impact of high quality bambara flour (HQBF) technology in the ... consumer acceptability/quality of products, credit, availability of raw materials, and ... as a result of 12.5 per cent increase in demand for bambara-based products.

  19. Development of a high-quality cut-off wall using electrophoresis

    International Nuclear Information System (INIS)

    Kawachi, T.; Murahashi, H.

    1991-01-01

    Techniques to build a high-quality cut-off wall have been developed for storage facilities of low-level radioactive waste (LLW) as an emergency measures to prevent leakages. The cut-off wall is highly impermeable, nucleid-adsorptive and have long-term durability. Electrophoresis is used to form impermeable membrane of bentonite as main features of the cut-off wall. First of all, laboratory tests have been conducted to study ways of building barriers on site and to collect data on the barriers properties. Afterwards, on-site construction tests of a high-quality cut-off wall have been carried out. In this paper, we describe the process and results on the studies of the high-quality cut-off wall using electrophoresis

  20. Timing of high-quality child care and cognitive, language, and preacademic development.

    Science.gov (United States)

    Li, Weilin; Farkas, George; Duncan, Greg J; Burchinal, Margaret R; Vandell, Deborah Lowe

    2013-08-01

    The effects of high- versus low-quality child care during 2 developmental periods (infant-toddlerhood and preschool) were examined using data from the National Institute of Child Health and Human Development Study of Early Child Care. Propensity score matching was used to account for differences in families who used different combinations of child care quality during the 2 developmental periods. Findings indicated that cognitive, language, and preacademic skills prior to school entry were highest among children who experienced high-quality care in both the infant-toddler and preschool periods, somewhat lower among children who experienced high-quality child care during only 1 of these periods, and lowest among children who experienced low-quality care during both periods. Irrespective of the care received during infancy-toddlerhood, high-quality preschool care was related to better language and preacademic outcomes at the end of the preschool period; high-quality infant-toddler care, irrespective of preschool care, was related to better memory skills at the end of the preschool period. (PsycINFO Database Record (c) 2013 APA, all rights reserved).

  1. Health-Related Quality of Life in Children with High-Functioning Autism

    Science.gov (United States)

    Potvin, Marie-Christine; Snider, Laurie; Prelock, Patricia A.; Wood-Dauphinee, Sharon; Kehayia, Eva

    2015-01-01

    The health-related quality of life of school-aged children with high-functioning autism is poorly understood. The objectives of this study were to compare the health-related quality of life of children with high-functioning autism to that of typically developing peers and to compare child-self and parent-proxy reports of health-related quality of…

  2. High quality digital holographic reconstruction on analog film

    Science.gov (United States)

    Nelsen, B.; Hartmann, P.

    2017-05-01

    High quality real-time digital holographic reconstruction, i.e. at 30 Hz frame rates, has been at the forefront of research and has been hailed as the holy grail of display systems. While these efforts have produced a fascinating array of computer algorithms and technology, many applications of reconstructing high quality digital holograms do not require such high frame rates. In fact, applications such as 3D holographic lithography even require a stationary mask. Typical devices used for digital hologram reconstruction are based on spatial-light-modulator technology and this technology is great for reconstructing arbitrary holograms on the fly; however, it lacks the high spatial resolution achievable by its analog counterpart, holographic film. Analog holographic film is therefore the method of choice for reconstructing highquality static holograms. The challenge lies in taking a static, high-quality digitally calculated hologram and effectively writing it to holographic film. We have developed a theoretical system based on a tunable phase plate, an intensity adjustable high-coherence laser and a slip-stick based piezo rotation stage to effectively produce a digitally calculated hologram on analog film. The configuration reproduces the individual components, both the amplitude and phase, of the hologram in the Fourier domain. These Fourier components are then individually written on the holographic film after interfering with a reference beam. The system is analogous to writing angularly multiplexed plane waves with individual component phase control.

  3. Consistency Across Standards or Standards in a New Business Model

    Science.gov (United States)

    Russo, Dane M.

    2010-01-01

    Presentation topics include: standards in a changing business model, the new National Space Policy is driving change, a new paradigm for human spaceflight, consistency across standards, the purpose of standards, danger of over-prescriptive standards, a balance is needed (between prescriptive and general standards), enabling versus inhibiting, characteristics of success-oriented standards, characteristics of success-oriented standards, and conclusions. Additional slides include NASA Procedural Requirements 8705.2B identifies human rating standards and requirements, draft health and medical standards for human rating, what's been done, government oversight models, examples of consistency from anthropometry, examples of inconsistency from air quality and appendices of government and non-governmental human factors standards.

  4. Employing industrial standards in software engineering for W7X

    Energy Technology Data Exchange (ETDEWEB)

    Kuehner, Georg [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Teilinstitut Greifswald, Wendelsteinstrasse 1, D-17491 Greifswald (Germany)], E-mail: kuehner@ipp.mpg.de; Bluhm, Torsten [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Teilinstitut Greifswald, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Heimann, Peter [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany); Hennig, Christine [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Teilinstitut Greifswald, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Kroiss, Hugo [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany); Krueger, Alexander [University of Applied Sciences, Schwedenschanze 135, 18435 Stralsund (Germany); Laqua, Heike; Lewerentz, Marc [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Teilinstitut Greifswald, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Maier, Josef [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany); Riemann, Heike; Schacht, Joerg; Spring, Anett; Werner, Andreas [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Teilinstitut Greifswald, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Zilker, Manfred [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany)

    2009-06-15

    The stellarator W7X is a large complex experiment designed for continuous operation and planned to be operated for about 20 years. Software support is highly demanded for experiment preparation, operation and data analysis which in turn induces serious non-functional requirements on the software quality like, e.g.: {center_dot}high availability, stability, maintainability vs. {center_dot}high flexibility concerning change of functionality, technology, personnel {center_dot}high versatility concerning the scale of system size and performance These challenges are best met by exploiting industrial experience in quality management and assurance (QM/QA), e.g. focusing on top-down development methods, developing an integral functional system model, using UML as a diagramming standard, building vertical prototypes, support for distributed development, etc., which have been used for W7X, however on an 'as necessary' basis. Proceeding in this manner gave significant results for control, data acquisition, corresponding database-structures and user applications over many years. As soon as production systems started using the software in the labs or on a prototype the development activity demanded to be organized in a more rigorous process mainly to provide stable operation conditions. Thus a process improvement activity was started for stepwise introduction of quality assuring processes with tool support taking standards like CMMI, ISO-15504 (SPICE) as a guideline. Experiences obtained so far will be reported. We conclude software engineering and quality assurance has to be an integral part of systems engineering right from the beginning of projects and be organized according to industrial standards to be prepared for the challenges of nuclear fusion research.

  5. Assessing Ecological Impacts of Shrimp and Sewage Effluent: Biological Indicators with Standard Water Quality Analyses

    Science.gov (United States)

    Jones, A. B.; O'Donohue, M. J.; Udy, J.; Dennison, W. C.

    2001-01-01

    Despite evidence linking shrimp farming to several cases of environmental degradation, there remains a lack of ecologically meaningful information about the impacts of effluent on receiving waters. The aim of this study was to determine the biological impact of shrimp farm effluent, and to compare and distinguish its impacts from treated sewage effluent. Analyses included standard water quality/sediment parameters, as well as biological indicators including tissue nitrogen (N) content, stable isotope ratio of nitrogen (δ 15N), and amino acid composition of inhabitant seagrasses, mangroves and macroalgae. The study area consisted of two tidal creeks, one receiving effluent from a sewage treatment plant and the other from an intensive shrimp farm. The creeks discharged into the western side of Moreton Bay, a sub-tropical coastal embayment on the east coast of Australia. Characterization of water quality revealed significant differences between the creeks, and with unimpacted eastern Moreton Bay. The sewage creek had higher concentrations of dissolved nutrients (predominantly NO-3/NO-2 and PO3-4, compared to NH+4 in the shrimp creek). In contrast, the shrimp creek was more turbid and had higher phytoplankton productivity. Beyond 750 m from the creek mouths, water quality parameters were indistinguishable from eastern Moreton Bay values. Biological indicators detected significant impacts up to 4 km beyond the creek mouths (reference site). Elevated plant δ 15N values ranged from 10·4-19·6‰ at the site of sewage discharge to 2·9-4·5‰ at the reference site. The free amino acid concentration and composition of seagrass and macroalgae was used to distinguish between the uptake of sewage and shrimp derived N. Proline (seagrass) and serine (macroalgae) were high in sewage impacted plants and glutamine (seagrass) and alanine (macroalgae) were high in plants impacted by shrimp effluent. The δ 15N isotopic signatures and free amino acid composition of inhabitant

  6. Development of national standards related to the integrated safety and security of high-rise buildings

    Science.gov (United States)

    Voskresenskaya, Elena; Vorona-Slivinskaya, Lubov

    2018-03-01

    The article considers the issues of developing national standards for high-rise construction. The system of standards should provide industrial, operational, economic and terrorist safety of high-rise buildings and facilities. Modern standards of high-rise construction should set the rules for designing engineering systems of high-rise buildings, which will ensure the integrated security of buildings, increase their energy efficiency and reduce the consumption of resources in construction and operation.

  7. ABACC laboratories quality assurance through Secondary Standards Exchange Program

    International Nuclear Information System (INIS)

    Guidicini, Olga Mafra; Thompson, Jay; Soriano, Michael

    2003-01-01

    In September 1999, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC), with assistance from the New Brunswick Laboratory (NBL) of the U.S. Department of Energy, started a new cooperative activity with, among other objectives, the production and characterization of a traceable uranium secondary standard and the performance of the Third Round Robin for ABACC's laboratory network. Brazil and Argentina have fabricated UO 2 pellets for use as a secondary standard. Samples from the two batches were sent to NBL for the determination of the reference values for both uranium concentration (%U) and isotopic composition for each batch. ABACC and NBL then organized the Third ABACC Round Robin for Brazilian and Argentine laboratories that are part of the ABACC network. The laboratories comprising the network can be used to analyze real samples collected during the ABACC inspections. The Brazilian and Argentine pellets were distributed to all the laboratories together with the protocol to be followed for the uranium concentration analysis, the forms for reporting the measurement results, and natural UO 2 pellets (CETAMA OU1) to be used as reference material. For the laboratories with capability of measuring isotopics, NBL reference material CRM 125-A was provided. Several laboratories from each country provided results. As soon as the measurement results were sent to the organizers, they were statistically evaluated by NBL. During a meeting held at ABACC headquarters with the participation of NBL representatives, the ABACC technical support officer, and representatives of all the participant laboratories, the results were discussed and compared with the reference values. All the laboratories had the occasion, in an open discussion, to explain and show the difficulties and problems they faced during the exercise. ABACC had the opportunity not only to judge the quality of the measurements these laboratories performed, but also to determine

  8. International standards for tuberculosis care: Relevance and implications for laboratory professionals

    Directory of Open Access Journals (Sweden)

    Pai M

    2007-01-01

    Full Text Available On World Tuberculosis (TB Day 2006, the International Standards for Tuberculosis Care (ISTC was officially released and widely endorsed by several agencies and organizations. The ISTC release was the culmination of a year long global effort to develop and set internationally acceptable, evidence-based standards for tuberculosis care. The ISTC describes a widely endorsed level of care that all practitioners, public and private, should seek to achieve in managing individuals who have or are suspected of having, TB and is intended to facilitate the effective engagement of all healthcare providers in delivering high quality care for patients of all ages, including those with smear-positive, smear-negative and extra-pulmonary TB, TB caused by drug-resistant Mycobacterium tuberculosis and TB/HIV coinfection. In this article, we present the ISTC, with a special focus on the diagnostic standards and describe their implications and relevance for laboratory professionals in India and worldwide. Laboratory professionals play a critical role in ensuring that all the standards are actually met by providing high quality laboratory services for smear microscopy, culture and drug susceptibility testing and other services such as testing for HIV infection. In fact, if the ISTC is widely followed, it can be expected that there will be a greater need and demand for quality assured laboratory services and this will have obvious implications for all laboratories in terms of work load, requirement for resources and trained personnel and organization of quality assurance systems.

  9. Mobility particle size spectrometers: harmonization of technical standards and data structure to facilitate high quality long-term observations of atmospheric particle number size distributions

    Directory of Open Access Journals (Sweden)

    A. Wiedensohler

    2012-03-01

    Full Text Available Mobility particle size spectrometers often referred to as DMPS (Differential Mobility Particle Sizers or SMPS (Scanning Mobility Particle Sizers have found a wide range of applications in atmospheric aerosol research. However, comparability of measurements conducted world-wide is hampered by lack of generally accepted technical standards and guidelines with respect to the instrumental set-up, measurement mode, data evaluation as well as quality control. Technical standards were developed for a minimum requirement of mobility size spectrometry to perform long-term atmospheric aerosol measurements. Technical recommendations include continuous monitoring of flow rates, temperature, pressure, and relative humidity for the sheath and sample air in the differential mobility analyzer.

    We compared commercial and custom-made inversion routines to calculate the particle number size distributions from the measured electrical mobility distribution. All inversion routines are comparable within few per cent uncertainty for a given set of raw data.

    Furthermore, this work summarizes the results from several instrument intercomparison workshops conducted within the European infrastructure project EUSAAR (European Supersites for Atmospheric Aerosol Research and ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network to determine present uncertainties especially of custom-built mobility particle size spectrometers. Under controlled laboratory conditions, the particle number size distributions from 20 to 200 nm determined by mobility particle size spectrometers of different design are within an uncertainty range of around ±10% after correcting internal particle losses, while below and above this size range the discrepancies increased. For particles larger than 200 nm, the uncertainty range increased to 30%, which could not be explained. The network reference mobility spectrometers with identical design agreed within ±4% in the

  10. Towards common technical standards

    International Nuclear Information System (INIS)

    Rahmat, H.; Suardi, A.R.

    1993-01-01

    In 1989, PETRONAS launched its Total Quality Management (TQM) program. In the same year the decision was taken by the PETRONAS Management to introduce common technical standards group wide. These standards apply to the design, construction, operation and maintenance of all PETRONAS installations in the upstream, downstream and petrochemical sectors. The introduction of common company standards is seen as part of an overall technical management system, which is an integral part of Total Quality Management. The Engineering and Safety Unit in the PETRONAS Central Office in Kuala Lumpur has been charged with the task of putting in place a set of technical standards throughout PETRONAS and its operating units

  11. Evaluation of medical record quality and communication skills among pediatric interns after standardized parent training history-taking in China.

    Science.gov (United States)

    Yu, Mu Xue; Jiang, Xiao Yun; Li, Yi Juan; Shen, Zhen Yu; Zhuang, Si Qi; Gu, Yu Fen

    2018-02-01

    The effect of using standardized parent training history-taking on the quality of medical records and communication skills among pediatric interns was determined. Fifth-year interns who were undertaking a pediatric clinical practice rotation were randomized to intervention and control groups. All of the pediatric interns received history-taking training by lecture and bedside teaching. The pediatric interns in the intervention group also received standardized parent history-taking training. The following two outcome measures were used: the scores of medical records, which were written by the pediatric interns after history-taking from real parents of pediatric patients; and the communication assessment tool (CAT) assessed by real parents. The general information, history of present illness (HPI), past medical history, personal history, family history, diagnosis, diagnostic analysis, and differential diagnosis scores in the intervention group were significantly higher than the control group (p history-taking is effective in improving the quality of medical records by pediatric interns. Standardized parent training history-taking is a superior teaching tool for clinical reasoning ability, as well as communication skills in clinical pediatric practice.

  12. Seasonal variations of ground water quality and its agglomerates by water quality index

    Directory of Open Access Journals (Sweden)

    S. Sharma

    2016-01-01

    Full Text Available Water is a unique natural resource among all sources available on earth. It plays an important role in economic development and the general well-being of the country. This study aimed at using the application of water quality index in evaluating the ground water quality innorth-east area of Jaipur in pre and post monsoon for public usage. Total eleven physico–chemical characteristics; total dissolved solids, total hardness,chloride, nitrate, electrical conductance, sodium, fluorideand potassium, pH, turbidity, temperature were analyzed and observed values were compared with standard values recommended by Indian standard and World Health Organization. Most of parameter show higher value than permissible limit in pre and post monsoon. Water quality index study showed that drinking water in Amer (221.58,277.70, Lalawas (362.74,396.67, Jaisinghpura area (286.00,273.78 were found to be highly contaminated due to high value of total dissolved solids, electrical conductance, total hardness, chloride, nitrate and sodium.Saipura (122.52, 131.00, Naila (120.25, 239.86, Galta (160.9, 204.1 were found to be moderately contaminated for both monsoons. People dependent on this water may prone to health hazard. Therefore some effective measures are urgently required to enhance the quality of water in these areas.

  13. Seasonal variations of ground water quality and its agglomerates by water quality index

    International Nuclear Information System (INIS)

    Sharma, S.; Chhipa, R.C.

    2016-01-01

    Water is a unique natural resource among all sources available on earth. It plays an important role in economic development and the general well-being of the country. This study aimed at using the application of water quality index in evaluating the ground water quality in north-east area of Jaipur in pre and post monsoon for public usage. Total eleven physico–chemical characteristics; total dissolved solids, total hardness,chloride, nitrate, electrical conductance, sodium, fluoride and potassium, p H, turbidity, temperature) were analyzed and observed values were compared with standard values recommended by Indian standard and World Health Organization. Most of parameter show higher value than permissible limit in pre and post monsoon. Water quality index study showed that drinking water in Amer (221.58,277.70), Lalawas (362.74,396.67), Jaisinghpura area (286.00, 273.78) were found to be highly contaminated due to high value of total dissolved solids, electrical conductance, total hardness, chloride, nitrate and sodium. Saipura (122.52, 131.00), Naila (120.25, 239.86), Galta (160.9, 204.1) were found to be moderately contaminated for both monsoons. People dependent on this water may prone to health hazard. Therefore some effective measures are urgently required to enhance the quality of water in these areas.

  14. German standard and German X-ray guide lines as a guide for quality assurance in X-ray diagnosis

    International Nuclear Information System (INIS)

    Pychlau, P.

    1985-01-01

    The German standard DIN 6868 (in preparation) and parts of the German X-ray Ordinance of 1973 deal with quality assurance in X-ray diagnosis. It is shown that both documents support each other and are a guidance for daily work. (author)

  15. Establishment of a Quality Management System Based on ISO 9001 Standard in a Public Service Fungal Culture Collection

    KAUST Repository

    Simoes, Marta; Dias, Nicolina; Santos, Cledir; Lima, Nelson

    2016-01-01

    to facilitate that process is to implement a Quality Management System (QMS) based on the ISO 9001 standard. Here, we report a detailed description of all the steps taken for the QMS implementation at the Portuguese CC of filamentous fungi: Micoteca da

  16. Next Generation Space Interconnect Standard (NGSIS): a modular open standards approach for high performance interconnects for space

    Science.gov (United States)

    Collier, Charles Patrick

    2017-04-01

    The Next Generation Space Interconnect Standard (NGSIS) effort is a Government-Industry collaboration effort to define a set of standards for interconnects between space system components with the goal of cost effectively removing bandwidth as a constraint for future space systems. The NGSIS team has selected the ANSI/VITA 65 OpenVPXTM standard family for the physical baseline. The RapidIO protocol has been selected as the basis for the digital data transport. The NGSIS standards are developed to provide sufficient flexibility to enable users to implement a variety of system configurations, while meeting goals for interoperability and robustness for space. The NGSIS approach and effort represents a radical departure from past approaches to achieve a Modular Open System Architecture (MOSA) for space systems and serves as an exemplar for the civil, commercial, and military Space communities as well as a broader high reliability terrestrial market.

  17. Development of national standards related to the integrated safety and security of high-rise buildings

    Directory of Open Access Journals (Sweden)

    Voskresenskaya Elena

    2018-01-01

    Full Text Available The article considers the issues of developing national standards for high-rise construction. The system of standards should provide industrial, operational, economic and terrorist safety of high-rise buildings and facilities. Modern standards of high-rise construction should set the rules for designing engineering systems of high-rise buildings, which will ensure the integrated security of buildings, increase their energy efficiency and reduce the consumption of resources in construction and operation.

  18. Variability in sunflower oil quality for biodiesel production: A simulation study

    International Nuclear Information System (INIS)

    Pereyra-Irujo, Gustavo A.; Izquierdo, Natalia G.; Covi, Mauro; Nolasco, Susana M.; Quiroz, Facundo; Aguirrezabal, Luis A.N.

    2009-01-01

    Biodiesel is an alternative fuel made from vegetable oils or animal fats. The fatty acid composition of the feedstock, which varies among and within species, is the main determinant of biodiesel quality. In this work we analyze the variability in biodiesel quality (density, kinematic viscosity, heating value, cetane number and iodine value) obtained from sunflower oil, by means of a validated crop model that predicts the fatty acid composition of one high-oleic, and three traditional (high-linoleic) sunflower hybrids. The model was run with a 10-year average weather data from 56 weather stations in Argentina, and simulation results were compared to the biodiesel standards of Argentina, USA and Europe. We show that biodiesel produced from sunflower oil does not have one fixed quality, but different qualities depending on weather conditions and agricultural practices, and that intraspecific variation in biodiesel quality can be larger than interspecific differences. Our results suggest that (a) sunflower oil from high-oleic hybrids is suitable for biodiesel production (within limits of all analyzed standards), regardless of growing conditions and (b) sunflower oil from traditional hybrids is suitable for biodiesel production under the standards of Argentina and USA, while only certain hybrids grown in warm regions (e.g., Northern Argentina, Southern USA, China, India, Pakistan) are suitable for biodiesel production according to the European standard

  19. Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Morton, Gerard C.; Loblaw, D. Andrew; Chung, Hans; Tsang, Gail; Sankreacha, Raxa; Deabreu, Andrea; Zhang Liying; Mamedov, Alexandre; Cheung, Patrick; Batchelar, Deidre; Danjoux, Cyril; Szumacher, Ewa

    2011-01-01

    Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domain score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose

  20. Quality control of secondary standards and calibration systems, therapy level, of National Laboratory of Metrology from Ionizing Radiations (LNMRI)

    International Nuclear Information System (INIS)

    Cecatti, E.R.; Freitas, L.C. de

    1992-01-01

    The results of quality control program of secondary standards, therapy level, and the calibration system of clinical dosemeters were analysed from 1984, when a change in the laboratory installation occurred and new standards were obtained. The national and the international intercomparisons were emphasised. The results for graphite wall chambers were compared, observing a maximum variation of about 0,6%. In the case of Delrin (TK01) wall chambers, the maximum variation was 1,7%. The results of post intercomparisons with thermoluminescent dosemeters have presented derivations lesser than 1%, securing the standards consistence at LNMRI with the international metrological system. (C.G.C.)