WorldWideScience

Sample records for high power millimeter-waves

  1. Microfabricated Millimeter-Wave High-Power Vacuum Electronic Amplifiers

    Science.gov (United States)

    2015-01-01

    colin.joye@nrl.navy.mil Microfabricated Millimeter-Wave High-Power Vacuum Electronic Amplifiers Figure 2. Results from the 220 GHz TWT . (a) Small signal...Completed tube under hot test. 220 GHz TWT Demonstration The 220 GHz TWT device was based on spare parts from a commercially available CPI VKY2444T G...existing parts, our TWT bested this COTS EIK performance by a factor of 12x in power and 50x in bandwidth for the same size, weight and prime power

  2. Millimeter-wave power amplifiers

    CERN Document Server

    du Preez, Jaco

    2017-01-01

    This book provides a detailed review of millimeter-wave power amplifiers, discussing design issues and performance limitations commonly encountered in light of the latest research. Power amplifiers, which are able to provide high levels of output power and linearity while being easily integrated with surrounding circuitry, are a crucial component in wireless microwave systems. The book is divided into three parts, the first of which introduces readers to mm-wave wireless systems and power amplifiers. In turn, the second focuses on design principles and EDA concepts, while the third discusses future trends in power amplifier research. The book provides essential information on mm-wave power amplifier theory, as well as the implementation options and technologies involved in their effective design, equipping researchers, circuit designers and practicing engineers to design, model, analyze, test and implement high-performance, spectrally clean and energy-efficient mm-wave systems.

  3. Strong Scattering of High Power Millimeter Waves in Tokamak Plasmas with Tearing Modes

    DEFF Research Database (Denmark)

    Westerhof, E.; Nielsen, Stefan Kragh; Oosterbeek, J.W.

    2009-01-01

    In tokamak plasmas with a tearing mode, strong scattering of high power millimeter waves, as used for heating and noninductive current drive, is shown to occur. This new wave scattering phenomenon is shown to be related to the passage of the O point of a magnetic island through the high power...... heating beam. The density determines the detailed phasing of the scattered radiation relative to the O-point passage. The scattering power depends strongly nonlinearly on the heating beam power. ©2009 The American Physical Society...

  4. Design of a Millimeter-Wave Concentrator for Beam Reception in High-Power Wireless Power Transfer

    Science.gov (United States)

    Fukunari, Masafumi; Wongsuryrat, Nat; Yamaguchi, Toshikazu; Nakamura, Yusuke; Komurasaki, Kimiya; Koizumi, Hiroyuki

    2017-02-01

    This study examined the performance of a developed taper-tube concentrator for 94-GHz millimeter-wave beam reception during wireless power transfer. The received energy is converted into kinetic energy of a working gas in the tube to drive an engine or thruster. The concentrator, which is assumed to have mirror reflection of millimeter waves in it, is designed to be shorter than conventional tapered waveguides of millimeter waves. A dimensionless design law of a concentrator is proposed based on geometric optics theory. Because the applicability of geometric optics theory is unclear, the ratio of its bore diameter to its wavelength was set as small compared to those in other possible applications. Then, the discrepancy between the designed and measured power reception was examined. Results show that the maximum discrepancy was as low as 7 % for the bore-to-wavelength ratio of 20 at the narrow end of the concentrator.

  5. Novel organic SMD package for high-power millimeter wave MMICs

    NARCIS (Netherlands)

    Heijningen, M. van; Friday, J.

    2004-01-01

    In this paper a novel low-cost SMD package for high-power MMICs is presented. Due to the special design this package has a very low thermal resistance and low parasitic ground inductance. 3D EM simulations of a packaged through-line correspond well with measurements. Measurement results of a 1 Watt

  6. Assessment methodology of counter-personnel high power electromagnetic millimeter wave effects

    NARCIS (Netherlands)

    Valente, F.; Horst, M.J. van der; Paulissen, J.J.M.; Zwamborn, A.P.M.; Toet, A.

    2013-01-01

    The group of NLW that arguably offers the largest amount of useful applications are based on high power electromagnetic millimetre wave technology. This group is often referred to as ‘Active Denial Systems’ (ADS), since they are primarily aimed at deterring and dispersing people out of an area. The

  7. Millimeter-Wave Power-Combining with Radiating Oscillator Arrays.

    Science.gov (United States)

    York, Robert Armstrong

    The next generation of communications and radar systems will soon begin to exploit the millimeter-wave portion of the electromagnetic spectrum. Such systems will require a high-power source of millimeter-wave energy, ideally small, lightweight, highly efficient, and failure -proof over a span of decades. Circuits using semiconductor devices have proved useful for this purpose at lower frequencies, but unfortunately the power generating capacity of solid -state devices diminishes quickly as frequencies approach 100 GHz. This has forced designers to use bulky, inefficient, and unreliable (but high-power) vacuum-tube sources. Combining the power produced by a large number of individual solid-state devices has been suggested as a means of overcoming the inherent limitations of millimeter -wave devices. In order to compete with vacuum-tube sources, power-combiners would require up to 1000 devices, presenting a difficult engineering challenge. This thesis introduces one possible solution to this problem. The proposed concept uses arrays of millimeter-wave oscillators, where each oscillator contains one or more active devices in a planar radiating structure. The oscillators are weakly coupled to synchronize frequency and phase relationships, and the power produced by each oscillator is radiatively combined in free-space, which gives rise to very high combining efficiencies. The array concept has been demonstrated at microwave frequencies using both Gunn and MESFET devices in a 4 x 4 patch antenna configuration. The Gunn array produced 22 Watts Equivalent Radiated Power (ERP), and the MESFET array produced 10 Watts ERP. A new theory has been developed which describes the coupled-oscillator dynamics, and has been shown to accurately predict experimentally observed effects. In addition to strict CW power-combining, a new mode of operation has been discovered which enables the same arrays to generate high-power pulses of energy. This new effect involves a "mode

  8. Research on Novel High-Power Microwave/Millimeter Wave Sources and Applications

    Science.gov (United States)

    2010-08-28

    theoretical support for the experiments at UC Davis aimed at the development of a zero-drive stable W-band gyrotron traveling-wave amplifier (Gyro- TWT ). The...this gyro- TWT ; namely, a new type of electron gun based on the robust, long-lived, clean, low work function, high current density thermionic cathodes...recently developed at UC Davis under the sponsorship of MURI-04. This is an electron gun to be used for the zero-drive stable Gyro- TWT . Our

  9. Experimental Verification on Remote Detectability of Concealed Radioactive Material Based on the Plasma Discharge Delay Time using High-Power Millimeter-Wave

    Science.gov (United States)

    Kim, Dongsung; Yu, Dongho; Sawant, Ashwini; Choe, Mun Seok; Lee, Ingeun; Choi, Eunmi

    2016-10-01

    We experimentally demonstrate a remote detection method of a radioactive source by plasma breakdown using high-power millimeter-wave source, gyrotron. A number of free electrons near the radioactive source are much higher than those of without the radioactive source (roughly 10 particles/cm3) owing to the interaction of air molecules and strong gamma rays generated by radioactive material. The RF wave beam is focused in ambient air, and the plasmas discharge occurs involving random delay time which means a time interval between the RF wave and a fluorescent light caused by the plasma. We observed that the delay time decreased significantly due to the high density of free electrons in Ar plasma with an existence of Co60 radioactive material. This technique of delay time measurement shows 1000 times more sensitive than a method of detectable mass equation to identify the existence of radioactive source remotely. It is the first experimental verification of radioactive material detection using a high power gyrotron. This study shows that a remote detection of radioactive material based on analysis of precise delay time measurement could be feasible by using a high power millimeter/THz wave gyrotron. NRF-2013R1A1A2061062, NRF-2012-Global Ph.D. Fellowship Program.

  10. System using a megawatt class millimeter wave source and a high-power rectenna to beam power to a suspended platform

    Energy Technology Data Exchange (ETDEWEB)

    Caplan, Malcolm; Friedman, Herbert W.

    2005-07-19

    A system for beaming power to a high altitude platform is based upon a high power millimeter gyrotron source, optical transmission components, and a high-power receiving antenna (i.e., a rectenna) capable of rectifying received millimeter energy and converting such energy into useable electrical power.

  11. Millimeter-Wave Wireless Power Transfer Technology for Space Applications

    Science.gov (United States)

    Chattopadhyay, Goutam; Manohara, Harish; Mojarradi, Mohammad M.; Vo, Tuan A.; Mojarradi, Hadi; Bae, Sam Y.; Marzwell, Neville

    2008-01-01

    In this paper we present a new compact, scalable, and low cost technology for efficient receiving of power using RF waves at 94 GHz. This technology employs a highly innovative array of slot antennas that is integrated on substrate composed of gold (Au), silicon (Si), and silicon dioxide (SiO2) layers. The length of the slots and spacing between them are optimized for a highly efficient beam through a 3-D electromagnetic simulation process. Antenna simulation results shows a good beam profile with very low side lobe levels and better than 93% antenna efficiency.

  12. High-gradient Millimeter-wave Accelerator on a Planar Dielectric Substrate/011

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Marc E

    2000-10-27

    We report the first high gradient studies of a millimeter-wave accelerator, employing for the first time a planar dielectric accelerator, powered by means of a 0.5-A, 300-MeV, 11.424-GHz drive electron beam, synchronous at the 8-th harmonic, 91.392 GHz. Embedded in a ring-resonator circuit within the electron beamline vacuum, this structure was operated at 20 MeV/m, with a circulating power of 200 kW, for 2 x 10{sup 5} pulses, with no sign of breakdown, dielectric charging or other deleterious high-gradient phenomena. We also present the first measurement of the quadrupolar content of an accelerating mode.

  13. Microwave and Millimeter-Wave Signal Power Generation

    DEFF Research Database (Denmark)

    Hadziabdic, Dzenan

    and relative bandwidth was 45%. Resistive loadings were used to ensure even and odd-mode stability. Another need in many direct conversion systems and image reject receivers is to generate signals with accurate quadrature offset. Only limited work has been published on design and analysis of mm-wave quadrature...... unwanted oscillations was proposed. The frequency tuning combines modulation of the coupling strength and modulation of the HBT capacitances. The developed QVCO demonstrated around -14.7 dBm power per single-ended output and state-of-the-art frequency and tuning range, 37-47.8 GHz. Simulated phase noise...

  14. Study on Millimeter-Wave Vivaldi Rectenna and Arrays with High Conversion Efficiency

    Directory of Open Access Journals (Sweden)

    Guan-Nan Tan

    2016-01-01

    Full Text Available A novel Vivaldi rectenna operated at 35 GHz with high millimeter wave to direct current (MMW-to-DC conversion efficiency is presented and the arrays are investigated. The measured conversion efficiency is 51.6% at 35 GHz and the efficiency higher than 30% is from 33.2 GHz to 36.6 GHz when the input MMW power is 79.4 mW. The receiving Vivaldi antenna loaded with metamaterial units has a high gain of 10.4 dBi at 35 GHz. A SIW- (substrate integrated waveguide- to-microstrip transition is designed not only to integrate the antenna with the rectifying circuit directly but also to provide the DC bypass for the rectifying circuit. When the power density is 8.7 mW/cm2, the received MMW power of the antenna is 5.6 mW, and the maximum conversion efficiency of the rectenna element is 31.5%. The output DC voltage of the element is nearly the same as that of the parallel array and is about half of the series array. The DC power obtained by the 1 × 2 rectenna arrays is about two times as much as that of the element. The conversion efficiencies of the arrays are very close to that of the element. Large scale arrays could be expended for collecting more DC power.

  15. Measurements on Fast switches and combiners (FADIS-BC for High-Power Millimeter-wave beams based on dielectric beam splitters

    Directory of Open Access Journals (Sweden)

    Moro A.

    2012-09-01

    Full Text Available An upgraded version of a quasi-optical diplexer combiner, based on a resonating system coupling two transmission lines using three Dielectric Beam Splitters, has been realized and tested. This device is principally thought to combine power coming from different transmission lines into a single output or to switch the injected power between different outputs, but it could also be used as mode filter or in line viewing system for Electron Cyclotron Emission (ECE or Collective Thomson Scattering (CTS diagnostics. The design was implemented in order to link two transmission lines of the ECRH system on FTU, for power combination of two beams into a single line of the new ECRH launcher recently installed. This device is based on Dielectric Beam Splitters (DBS; it has been tested at low power in order to confirm the splitting ratio foreseen from simulation and its efficiency has been evaluated measuring the beam exiting the system. The design and the characterization of the diplexer combiner are reported in this paper.

  16. Wafer scale millimeter-wave integrated circuits based on epitaxial graphene in high data rate communication.

    Science.gov (United States)

    Habibpour, Omid; He, Zhongxia Simon; Strupinski, Wlodek; Rorsman, Niklas; Zirath, Herbert

    2017-02-01

    In recent years, the demand for high data rate wireless communications has increased dramatically, which requires larger bandwidth to sustain multi-user accessibility and quality of services. This can be achieved at millimeter wave frequencies. Graphene is a promising material for the development of millimeter-wave electronics because of its outstanding electron transport properties. Up to now, due to the lack of high quality material and process technology, the operating frequency of demonstrated circuits has been far below the potential of graphene. Here, we present monolithic integrated circuits based on epitaxial graphene operating at unprecedented high frequencies (80-100 GHz). The demonstrated circuits are capable of encoding/decoding of multi-gigabit-per-second information into/from the amplitude or phase of the carrier signal. The developed fabrication process is scalable to large wafer sizes.

  17. Wafer scale millimeter-wave integrated circuits based on epitaxial graphene in high data rate communication

    Science.gov (United States)

    Habibpour, Omid; He, Zhongxia Simon; Strupinski, Wlodek; Rorsman, Niklas; Zirath, Herbert

    2017-02-01

    In recent years, the demand for high data rate wireless communications has increased dramatically, which requires larger bandwidth to sustain multi-user accessibility and quality of services. This can be achieved at millimeter wave frequencies. Graphene is a promising material for the development of millimeter-wave electronics because of its outstanding electron transport properties. Up to now, due to the lack of high quality material and process technology, the operating frequency of demonstrated circuits has been far below the potential of graphene. Here, we present monolithic integrated circuits based on epitaxial graphene operating at unprecedented high frequencies (80-100 GHz). The demonstrated circuits are capable of encoding/decoding of multi-gigabit-per-second information into/from the amplitude or phase of the carrier signal. The developed fabrication process is scalable to large wafer sizes.

  18. On Bit Error Probability and Power Optimization in Multihop Millimeter Wave Relay Systems

    KAUST Repository

    Chelli, Ali

    2018-01-15

    5G networks are expected to provide gigabit data rate to users via millimeter-wave (mmWave) communication technology. One of the major problem faced by mmWaves is that they cannot penetrate buildings. In this paper, we utilize multihop relaying to overcome the signal blockage problem in mmWave band. The multihop relay network comprises a source device, several relay devices and a destination device and uses device-todevice communication. Relay devices redirect the source signal to avoid the obstacles existing in the propagation environment. Each device amplifies and forwards the signal to the next device, such that a multihop link ensures the connectivity between the source device and the destination device. We consider that the relay devices and the destination device are affected by external interference and investigate the bit error probability (BEP) of this multihop mmWave system. Note that the study of the BEP allows quantifying the quality of communication and identifying the impact of different parameters on the system reliability. In this way, the system parameters, such as the powers allocated to different devices, can be tuned to maximize the link reliability. We derive exact expressions for the BEP of M-ary quadrature amplitude modulation (M-QAM) and M-ary phase-shift keying (M-PSK) in terms of multivariate Meijer’s G-function. Due to the complicated expression of the exact BEP, a tight lower-bound expression for the BEP is derived using a novel Mellin-approach. Moreover, an asymptotic expression for the BEP at high SIR regime is derived and used to determine the diversity and the coding gain of the system. Additionally, we optimize the power allocation at different devices subject to a sum power constraint such that the BEP is minimized. Our analysis reveals that optimal power allocation allows achieving more than 3 dB gain compared to the equal power allocation.This research work can serve as a framework for designing and optimizing mmWave multihop

  19. Millimeter Wave Fabry-Perot Resonator Antenna Fed by CPW with High Gain and Broadband

    OpenAIRE

    Xue-Xia Yang; Guan-Nan Tan; Bing Han; Hai-Gao Xue

    2016-01-01

    A novel millimeter wave coplanar waveguide (CPW) fed Fabry-Perot (F-P) antenna with high gain, broad bandwidth, and low profile is reported. The partially reflective surface (PRS) and the ground form the F-P resonator cavity, which is filled with the same dielectric substrate. A dual rhombic slot loop on the ground acts as the primary feeding antenna, which is fed by the CPW and has broad bandwidth. In order to improve the antenna gain, metal vias are inserted surrounding the F-P cavity. A CP...

  20. Design and modeling of InP DHBT power amplifiers at millimeter-wave frequencies

    DEFF Research Database (Denmark)

    Yan, Lei; Johansen, Tom K.

    2012-01-01

    In this paper, the design and modeling of InP DHBT based millimeter-wave(mm-wave) power amplifiers is described. This includes the modeling of InP DHBT devices and layout parasitics. An EM-circuit co-simulation approach is described to allow all parasitics to be modeled for accurate circuit...... performance evaluation. A single-branch cascode based PA using single-finger InP DHBT devices shows a measured power gain of 9.2dB and a saturated output power of 12.3dBm at 67.2GHz. The output power at 1dB compression is 9.0dBm. A similar two-way combined cascode based PA using three-finger devices...... demonstrates a power gain of 4.5dB with a saturated output power of 14.2dBm at 69.2GHz. © 2012 European Microwave Assoc....

  1. First Eigenmode Transmission by High Efficient CSI Estimation for Multiuser Massive MIMO Using Millimeter Wave Bands

    Directory of Open Access Journals (Sweden)

    Kazuki Maruta

    2016-07-01

    Full Text Available Drastic improvements in transmission rate and system capacity are required towards 5th generation mobile communications (5G. One promising approach, utilizing the millimeter wave band for its rich spectrum resources, suffers area coverage shortfalls due to its large propagation loss. Fortunately, massive multiple-input multiple-output (MIMO can offset this shortfall as well as offer high order spatial multiplexing gain. Multiuser MIMO is also effective in further enhancing system capacity by multiplexing spatially de-correlated users. However, the transmission performance of multiuser MIMO is strongly degraded by channel time variation, which causes inter-user interference since null steering must be performed at the transmitter. This paper first addresses the effectiveness of multiuser massive MIMO transmission that exploits the first eigenmode for each user. In Line-of-Sight (LoS dominant channel environments, the first eigenmode is chiefly formed by the LoS component, which is highly correlated with user movement. Therefore, the first eigenmode provided by a large antenna array can improve the robustness against the channel time variation. In addition, we propose a simplified beamforming scheme based on high efficient channel state information (CSI estimation that extracts the LoS component. We also show that this approximate beamforming can achieve throughput performance comparable to that of the rigorous first eigenmode transmission. Our proposed multiuser massive MIMO scheme can open the door for practical millimeter wave communication with enhanced system capacity.

  2. Power line characterization from an airborne data collection with a millimeter wave radar

    Science.gov (United States)

    Goshi, Darren S.; Bui, Long Q.

    2014-05-01

    Enhancing the operational safety of small, maneuverable rotorcraft has been a critical consideration in the development of next generation situational awareness sensor suites. From landing assistance to target detection and obstacle avoidance, millimeter wave radars have become the leading candidate for such solutions due to their ability to operate in degraded visual environments, whether it is weather, induced debris, or night conditions that must be dealt with. Power lines pose arguably the largest safety risk for helicopter operation due to their difficulty in detection and proper identification to support avoidance maneuvering, where even under perfect conditions they can be nearly invisible to the naked eye. The backscatter phenomenology from braided power lines has been well-studied and formulated in previous literature, albeit mainly in controlled laboratory settings or limited field trials. Subsequently, the ability to simply detect power lines at operational distances up to around 2 km has been demonstrated. In this work, an analysis is performed on the measureable characteristics of power lines captured in a representative operational environment for helicopters. The test location included a diverse set of power line configurations with surrounding ground and tower clutter, representing a realistic scenario. A radiometrically calibrated w-band real-beam FMCW sensor allows the study and estimation of target RCS, as well as evaluation against the developed theory. All analysis is performed on dynamically captured data from a helicopter, where platform dynamics and system stability also play a significant role in a processed result. Results from this work will aid the effective development of next generation situational awareness systems.

  3. Millimeter Wave Hybrid Photonic Wireless Links for High-Speed Wireless Access and Mobile Fronthaul

    DEFF Research Database (Denmark)

    Rommel, Simon

    require a complete re-thinking of radio access networks – one important aspect of which is the introduction of millimeter wave communications, which is expected to play a key role. Millimeter wave hybrid photonic wireless links seamlessly merge the wired optical and wireless radio network segments...... of spectral efficiency is achieved for rof links in W-band using multi-band carrierless amplitude phase modulation (multicap), the first experimental validation of wavelet coding for robustness against frequency fading is performed, and the combination of multicap with non-orthogonal multiple access...... and combine the best of both technologies, offering very large capacity and bridging long distances with optical fiber, while retaining the flexibility and easy deployment of wireless communications. The research in this thesis experimentally investigates millimeter wave (mmw) hybrid photonic wireless links...

  4. The high resolution spectrum of methyltrioxorhenium reinvestigated with new infrared and millimeter-wave measurements

    CERN Document Server

    Asselin, Pierre; Huet, Thérèse; Margulès, Laurent; Motiyenko, Roman; Hendricks, Richard; Tarbutt, Michael; Tokunaga, Sean; Darquié, Benoît

    2016-01-01

    Following our first paper about high resolution spectroscopy of methyltrioxorhenium (MTO) [Stoeffler et al. PCCP, 13, 854, (2011)], the present study reports a deeper investigation of the ground state, and Re=O antisymmetric (nu\\_as) and symmetric (nu\\_s) stretching excited states of both CH3(187Re)O3 and CH3(185Re)O3 isotopologues, thanks to new devices implemented within our consortium. We carry out high resolution millimeter-wave (MMW) and infrared (IR) spectroscopy in room temperature absorption cells, in a pulsed supersonic jet and in a cryogenic buffer gas cell. This collection of sensitive spectrometers enables us to probe both levels of a vibrational transition in low and room temperature gaseous environments. We thus report a new series of measurements providing particularly accurate rotational and rovibrational data for such a large and heavy organometallic molecule that is solid at room temperature.The combination of the new MMW and IR data leads to an improvement of the rovibrational model of MTO:...

  5. Millimeter Wave Fabry-Perot Resonator Antenna Fed by CPW with High Gain and Broadband

    Directory of Open Access Journals (Sweden)

    Xue-Xia Yang

    2016-01-01

    Full Text Available A novel millimeter wave coplanar waveguide (CPW fed Fabry-Perot (F-P antenna with high gain, broad bandwidth, and low profile is reported. The partially reflective surface (PRS and the ground form the F-P resonator cavity, which is filled with the same dielectric substrate. A dual rhombic slot loop on the ground acts as the primary feeding antenna, which is fed by the CPW and has broad bandwidth. In order to improve the antenna gain, metal vias are inserted surrounding the F-P cavity. A CPW-to-microstrip transition is designed to measure the performances of the antenna and extend the applications. The measured impedance bandwidth of S11 less than −10 dB is from 34 to 37.7 GHz (10.5%, and the gain is 15.4 dBi at the center frequency of 35 GHz with a 3 dB gain bandwidth of 7.1%. This performance of the antenna shows a tradeoff among gain, bandwidth, and profile.

  6. Topics in millimeter wave technology

    CERN Document Server

    Button, Kenneth

    1988-01-01

    Topics in Millimeter Wave Technology, Volume 1 presents topics related to millimeter wave technology, including fin-lines and passive components realized in fin-lines, suspended striplines, suspended substrate microstrips, and modal power exchange in multimode fibers. A miniaturized monopulse assembly constructed in planar waveguide with multimode scalar horn feeds is also described. This volume is comprised of five chapters; the first of which deals with the analysis and synthesis techniques for fin-lines as well as the various passive components realized in fin-line. Tapers, discontinuities,

  7. Design of InP DHBT power amplifiers at millimeter-wave frequencies using interstage matched cascode technique

    DEFF Research Database (Denmark)

    Yan, Lei; Johansen, Tom Keinicke

    2013-01-01

    In this paper, the design of InP DHBT based millimeter-wave(mm-wave) power amplifiers(PAs) using an interstage matched cascode technique is presented. The output power of a traditional cascode is limited by the early saturation of the common-base(CB) device. The interstage matched cascode can...... be employed to improve the power handling ability through optimizing the input impedance of the CB device. The minimized power mismatch between the CB and the common-emitter(CE) devices results in an improved saturated output power. To demonstrate the technique for power amplifier designs at mm......-wave frequencies, a single-branch cascode based PA using single-finger devices and a two-way combined based PA using three-finger devices are fabricated. The single-branch design shows a measured power gain of 9.2dB and a saturated output power of 12.3dBm at 67.2GHz and the two-way combined design shows a power...

  8. Improvement of breakdown characteristics of an AlGaN/GaN HEMT with a U-type gate foot for millimeter-wave power application

    Science.gov (United States)

    Kong, Xin; Wei, Ke; Liu, Guo-Guo; Liu, Xin-Yu

    2012-12-01

    In this study, the physics-based device simulation tool Silvaco ATLAS is used to characterize the electrical properties of an AlGaN/GaN high electron mobility transistor (HEMT) with a U-type gate foot. The U-gate AlGaN/GaN HEMT mainly features a gradually changed sidewall angle, which effectively mitigates the electric field in the channel, thus obtaining enhanced off-state breakdown characteristics. At the same time, only a small additional gate capacitance and decreased gate resistance ensure excellent RF characteristics for the U-gate device. U-gate AlGaN/GaN HEMTs are feasible through adjusting the etching conditions of an inductively coupled plasma system, without introducing any extra process steps. The simulation results are confirmed by experimental measurements. These features indicate that U-gate AlGaN/GaN HEMTs might be promising candidates for use in millimeter-wave power applications.

  9. Focusing millimeter wave radar for radial gap measurements in power plant combustion turbines; Fokussierendes Radarverfahren im Millimeterwellenbereich zur Radialspaltmessung in Kraftwerksturbinen

    Energy Technology Data Exchange (ETDEWEB)

    Schicht, Andreas

    2011-07-11

    In this work a method for spatially resolved radial gap measurements in power plant combustion turbines by means of an autofocusing imaging radar technique in the millimeter wave range was developed and verified experimentally. The radial gap measurement has been subject of engineering studies for many years, as a reliable, simple solution does not seem to be possible due to the given boundary conditions. These include on the one hand the adverse measurement conditions such as high temperature and pressure, corrosive atmosphere and high speed of motion. On the other hand, the geometrical structure of the rotor blades at their tips turns out to be a key problem for the distance measurement. In particular, the blade tip is composed of small extended portions forming thin ribs of only a few millimeters width. Many established distance sensors like e. g. capacitive sensors cannot detect the correct tip clearance of the blade edge independently from other structures on the blade end only due to their large surface area and thus their lack of spatial resolution. The problem of small structure sizes is overcome by choosing a synthetic aperture radar (SAR) in the millimeter wave range capable of resolving the edges of a typical blade tip. The clearance is determined by measuring the reflection at the blade tip while passing by the antenna, subsequently focusing the data by means of a matched filter operation and interpreting the phase of the blade edge reflection according to the CW radar principle. For this, an autofocus approach was developed, which provides an estimate of the clearance as a first result, which is utilized to overcome the phase ambiguity and thus to increase the measurement range. The autofocus algorithm applies a weighted phase gradient of the point-like blade edge reflection as cost function and sensitive indicator for the focal quality.

  10. Power line identification of millimeter wave radar based on PCA-GS-SVM

    Science.gov (United States)

    Fang, Fang; Zhang, Guifeng; Cheng, Yansheng

    2017-12-01

    Aiming at the problem that the existing detection method can not effectively solve the security of UAV's ultra low altitude flight caused by power line, a power line recognition method based on grid search (GS) and the principal component analysis and support vector machine (PCA-SVM) is proposed. Firstly, the candidate line of Hough transform is reduced by PCA, and the main feature of candidate line is extracted. Then, upport vector machine (SVM is) optimized by grid search method (GS). Finally, using support vector machine classifier optimized parameters to classify the candidate line. MATLAB simulation results show that this method can effectively identify the power line and noise, and has high recognition accuracy and algorithm efficiency.

  11. Millimeter-wave antennas configurations and applications

    CERN Document Server

    du Preez, Jaco

    2016-01-01

    This book comprehensively reviews the state of the art in millimeter-wave antennas, traces important recent developments and provides information on a wide range of antenna configurations and applications. While fundamental theoretical aspects are discussed whenever necessary, the book primarily focuses on design principles and concepts, manufacture, measurement techniques, and practical results. Each of the various antenna types scalable to millimeter-wave dimensions is considered individually, with coverage of leaky-wave and surface-wave antennas, printed antennas, integrated antennas, and reflector and lens systems. The final two chapters address the subject from a systems perspective, providing an overview of supporting circuitry and examining in detail diverse millimeter-wave applications, including high-speed wireless communications, radio astronomy, and radar. The vast amount of information now available on millimeter-wave systems can be daunting for researchers and designers entering the field. This b...

  12. Millimeter-Wave Dielectric Properties of Single Crystal Ferroelectric and Dielectric Materials

    Energy Technology Data Exchange (ETDEWEB)

    McCloy, John S.; Korolev, Konstantin A.; Li, Zijing; Afsar, Mohammed N.; Sundaram, S. K.

    2011-01-03

    Transmittance measurements on various single crystal ferroelectric materials over a broad millimeter-wave frequency range have been performed. Frequency dependence of the complex dielectric permittivity has been determined in the millimeter wave region for the first time. The measurements have been employed using a free-space quasi-optical millimeter-wave spectrometer equipped with a set of high power backward wave oscillators (BWOs) as sources of coherent radiation, tunable in the range from 30 - 120 GHz. The uncertainties and possible sources of instrumentation and measurement errors related to the free-space millimeter-wave technique are discussed. This work has demonstrated that precise MMW permittivities can be obtained even on small thin crystals using the BWO quasi-optical approach.

  13. Low-power Broadband Digitizer for Millimeter-Wave Sensor Array Readout Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Multiplexing in frequency domain using a bank of high-Q micro-resonators is an emerging method of reading out large arrays of transition-edge sensors and...

  14. Universal Millimeter-Wave Radar Front End

    Science.gov (United States)

    Perez, Raul M.

    2010-01-01

    A quasi-optical front end allows any arbitrary polarization to be transmitted by controlling the timing, amplitude, and phase of the two input ports. The front end consists of two independent channels horizontal and vertical. Each channel has two ports transmit and receive. The transmit signal is linearly polarized so as to pass through a periodic wire grid. It is then propagated through a ferrite Faraday rotator, which rotates the polarization state 45deg. The received signal is propagated through the Faraday rotator in the opposite direction, undergoing a further 45 of polarization rotation due to the non-reciprocal action of the ferrite under magnetic bias. The received signal is now polarized at 90deg relative to the transmit signal. This signal is now reflected from the wire grid and propagated to the receive port. The horizontal and vertical channels are propagated through, or reflected from, another wire grid. This design is an improvement on the state of the art in that any transmit signal polarization can be chosen in whatever sequence desired. Prior systems require switching of the transmit signal from the amplifier, either mechanically or by using high-power millimeter-wave switches. This design can have higher reliability, lower mass, and more flexibility than mechanical switching systems, as well as higher reliability and lower losses than systems using high-power millimeter-wave switches.

  15. Strategic Control of 60 GHz Millimeter-Wave High-Speed Wireless Links for Distributed Virtual Reality Platforms

    Directory of Open Access Journals (Sweden)

    Joongheon Kim

    2017-01-01

    Full Text Available This paper discusses the stochastic and strategic control of 60 GHz millimeter-wave (mmWave wireless transmission for distributed and mobile virtual reality (VR applications. In VR scenarios, establishing wireless connection between VR data-center (called VR server (VRS and head-mounted VR device (called VRD allows various mobile services. Consequently, utilizing wireless technologies is obviously beneficial in VR applications. In order to transmit massive VR data, the 60 GHz mmWave wireless technology is considered in this research. However, transmitting the maximum amount of data introduces maximum power consumption in transceivers. Therefore, this paper proposes a dynamic/adaptive algorithm that can control the power allocation in the 60 GHz mmWave transceivers. The proposed algorithm dynamically controls the power allocation in order to achieve time-average energy-efficiency for VR data transmission over 60 GHz mmWave channels while preserving queue stabilization. The simulation results show that the proposed algorithm presents desired performance.

  16. Millimeter waves or extremely high frequency electromagnetic fields in the environment: what are their effects on bacteria?

    Science.gov (United States)

    Soghomonyan, Diana; Trchounian, Karen; Trchounian, Armen

    2016-06-01

    Millimeter waves (MMW) or electromagnetic fields of extremely high frequencies at low intensity is a new environmental factor, the level of which is increased as technology advance. It is of interest that bacteria and other cells might communicate with each other by electromagnetic field of sub-extremely high frequency range. These MMW affected Escherichia coli and many other bacteria, mainly depressing their growth and changing properties and activity. These effects were non-thermal and depended on different factors. The significant cellular targets for MMW effects could be water, cell plasma membrane, and genome. The model for the MMW interaction with bacteria is suggested; a role of the membrane-associated proton FOF1-ATPase, key enzyme of bioenergetic relevance, is proposed. The consequences of MMW interaction with bacteria are the changes in their sensitivity to different biologically active chemicals, including antibiotics. Novel data on MMW effects on bacteria and their sensitivity to different antibiotics are presented and discussed; the combined action of MMW and antibiotics resulted with more strong effects. These effects are of significance for understanding changed metabolic pathways and distinguish role of bacteria in environment; they might be leading to antibiotic resistance in bacteria. The effects might have applications in the development of technique, therapeutic practices, and food protection technology.

  17. High temperature millimeter wave radiometric and interferometric measurements of slag-refractory interaction for application to coal gasifiers

    Energy Technology Data Exchange (ETDEWEB)

    McCloy, John S.; Crum, Jarrod V.; Sundaram, S. K.; Slaugh, Ryan W.; Woskov, Paul P.

    2011-09-17

    Millimeter wave (MMW) radiometry can be used for simultaneous measurement of emissivity and temperature of materials under extreme environments (high temperature, pressure, and corrosive environments) such as in slagging coal gasifiers, where sensors have been identified as a key enabling technology need for process optimization. We present a state-of-the-art dual-channel MMW heterodyne radiometer with active interferometric capability that allows simultaneous radiometric measurements of sample temperature, emissivity, and flow dynamics to over 1873 K. Interferometric capability is supplied via a probe signal originating from the 137 GHz radiometer local oscillator (LO). The interferometric 'video' channels allow measurement of additional parameters simultaneously, such as volume expansion, thickness change, and slag viscosity along with temperature or emissivity. This capability has been used to demonstrate measurement of temperature and simulated coal slag infiltration into a chromia refractory brick sample as well as slag flow down a vertically placed refractory brick. Observed phenomena include slag melting and slumping, slag reboil and foam with oxygen evolution, and eventual failure of the alumina crucible through corrosion by the molten slag. These results show the promise of the MMW system for extracting quantitative and qualitative process parameters from operating slagging coal gasifiers, providing valuable information for process efficiency, control, and increased productivity.

  18. Compressive passive millimeter wave imager

    Science.gov (United States)

    Gopalsami, Nachappa; Liao, Shaolin; Elmer, Thomas W; Koehl, Eugene R; Heifetz, Alexander; Raptis, Apostolos C

    2015-01-27

    A compressive scanning approach for millimeter wave imaging and sensing. A Hadamard mask is positioned to receive millimeter waves from an object to be imaged. A subset of the full set of Hadamard acquisitions is sampled. The subset is used to reconstruct an image representing the object.

  19. Development of a High Resolution Airborne Millimeter Wave FM-CW SAR

    NARCIS (Netherlands)

    Meta, A.; Wit, J.J.M. de; Hoogeboom, P.

    2004-01-01

    The combination of compact FM-CW radar technology and high resolution SAR processing techniques should pave the way for the development of a small, lightweight and cost effective imaging radar. In the field of airborne earth observation, SAR is however a novel application for FM-CW radars. At IRCTR

  20. Development of Signal Processing Algorithms for High Resolution Airborne Millimeter Wave FMCW SAR

    NARCIS (Netherlands)

    Meta, A.; Hoogeboom, P.

    2005-01-01

    For airborne earth observation applications, there is a special interest in lightweight, cost effective, imaging sensors of high resolution. The combination of Frequency Modulated Continuous Wave (FMCW) technology and Synthetic Aperture Radar (SAR) techniques can lead to such a sensor. In this

  1. High quality silicon-based substrates for microwave and millimeter wave passive circuits

    Science.gov (United States)

    Belaroussi, Y.; Rack, M.; Saadi, A. A.; Scheen, G.; Belaroussi, M. T.; Trabelsi, M.; Raskin, J.-P.

    2017-09-01

    Porous silicon substrate is very promising for next generation wireless communication requiring the avoidance of high-frequency losses originating from the bulk silicon. In this work, new variants of porous silicon (PSi) substrates have been introduced. Through an experimental RF performance, the proposed PSi substrates have been compared with different silicon-based substrates, namely, standard silicon (Std), trap-rich (TR) and high resistivity (HR). All of the mentioned substrates have been fabricated where identical samples of CPW lines have been integrated on. The new PSi substrates have shown successful reduction in the substrate's effective relative permittivity to values as low as 3.7 and great increase in the substrate's effective resistivity to values higher than 7 kΩ cm. As a concept proof, a mm-wave bandpass filter (MBPF) centred at 27 GHz has been integrated on the investigated substrates. Compared with the conventional MBPF implemented on standard silicon-based substrates, the measured S-parameters of the PSi-based MBPF have shown high filtering performance, such as a reduction in insertion loss and an enhancement of the filter selectivity, with the joy of having the same filter performance by varying the temperature. Therefore, the efficiency of the proposed PSi substrates has been well highlighted. From 1994 to 1995, she was assistant of physics at (USTHB), Algiers . From 1998 to 2011, she was a Researcher at characterization laboratory in ionized media and laser division at the Advanced Technologies Development Center. She has integrated the Analog Radio Frequency Integrated Circuits team as Researcher since 2011 until now in Microelectronic and Nanotechnology Division at Advanced Technologies Development Center (CDTA), Algiers. She has been working towards her Ph.D. degree jointly at CDTA and Ecole Nationale Polytechnique, Algiers, since 2012. Her research interest includes fabrication and characterization of microwave passive devices on porous

  2. Millimeter waves: acoustic and electromagnetic.

    Science.gov (United States)

    Ziskin, Marvin C

    2013-01-01

    This article is the presentation I gave at the D'Arsonval Award Ceremony on June 14, 2011 at the Bioelectromagnetics Society Annual Meeting in Halifax, Nova Scotia. It summarizes my research activities in acoustic and electromagnetic millimeter waves over the past 47 years. My earliest research involved acoustic millimeter waves, with a special interest in diagnostic ultrasound imaging and its safety. For the last 21 years my research expanded to include electromagnetic millimeter waves, with a special interest in the mechanisms underlying millimeter wave therapy. Millimeter wave therapy has been widely used in the former Soviet Union with great reported success for many diseases, but is virtually unknown to Western physicians. I and the very capable members of my laboratory were able to demonstrate that the local exposure of skin to low intensity millimeter waves caused the release of endogenous opioids, and the transport of these agents by blood flow to all parts of the body resulted in pain relief and other beneficial effects. Copyright © 2012 Wiley Periodicals, Inc.

  3. Convergence of millimeter-wave and photonic interconnect systems for very-high-throughput digital communication applications

    Science.gov (United States)

    Fan, Shu-Hao

    In the past, radio-frequency signals were commonly used for low-speed wireless electronic systems, and optical signals were used for high-speed wired communication systems. However, as the emergence of new millimeter-wave technology, which is capable of providing multi-gigabit transmission over a wireless radio-frequency channel, the borderline between radio-frequency and optical transport systems becomes blurred. As a result, there are ample opportunities to design and develop next-generation broadband systems by combining the advantages of these two technologies to overcome inherent limitations of various broadband end-to-end interconnects, such as signal generation, transportation, data recovery, and synchronization. For the transmission distances of a few centimeters to thousands of kilometers, the integration of radio-frequency electronics and photonics to build radio-over-fiber systems ushers in a new era of research opportunity for the upcoming very-high-throughput broadband services. Recent developments in radio-over-fiber systems have garnered momentum to be recognized as the most promising solution for the backhaul transmission of multi-gigabit wireless access networks, especially for the license-free, very-high-throughput 60-GHz band. Adopting radio-over-fiber systems in local-access or in-building networks can greatly extend 60-GHz signal reach by using ultra-low loss optical fibers. However, systems operating at such high frequency are difficult to generate in an old fashion way. In this dissertation, several novel techniques of homodyne and heterodyne optical-carrier suppressions for radio-over-fiber systems are investigated and various system architectures are designed to overcome these limitations of 60-GHz wireless access networks, bringing the dream of delivering multi-gigabit wireless services of any content, at anytime and anywhere closer to the reality. In addition to the advantages for the access networks, extremely high spectral efficiency

  4. Superconducting submillimeter and millimeter wave detectors

    Energy Technology Data Exchange (ETDEWEB)

    Nahum, M.

    1992-10-20

    The series of projects described in this dissertation was stimulated by the discovery of high temperature superconductivity. Our goal was to develop useful applications which would be competitive with the current state of technology. The high-[Tc] microbolometer was developed into the most sensitive direct detector of millimeter waves, when operated at liquid nitrogen temperatures. The thermal boundary resistance of thin YBa[sub 2]Cu[sub 3]0[sub 7-[delta

  5. Millimeter Wave Holographical Inspection of Honeycomb Composites

    Science.gov (United States)

    Case, J. T.; Kharkovsky, S.; Zoughi, R.; Stefes, G.; Hepburn, Frank L.; Hepburn, Frank L.

    2007-01-01

    Multi-layered composite structures manufactured with honeycomb, foam or balsa wood cores are finding increasing utility in a variety of aerospace, transportation, and infrastructure applications. Due to the low conductivity and inhomogeneity associated with these composites standard nondestructive testing (NDT) methods are not always capable of inspecting their interior for various defects caused during the manufacturing process or as a result of in-service loading. On the contrary, microwave and millimeter wave NDT methods are well-suited for inspecting these structures since signals at these frequencies readily penetrate through these structures and reflect from different interior boundaries revealing the presence of a wide range of defects such as disbond, delamination, moisture and oil intrusion, impact damage, etc. Millimeter wave frequency spectrum spans 30 GHz - 300 GHz with corresponding wavelengths of 10 - 1 mm. Due to the inherent short wavelengths at these frequencies, one can produce high spatial resolution images of these composites either using real-antenna focused or synthetic-aperture focused methods. In addition, incorporation of swept-frequency in the latter method (i.e., holography) results in high-resolution three-dimensional images. This paper presents the basic steps behind producing such images at millimeter wave frequencies and the results of two honeycomb composite panels are demonstrated at Q-band (33-50 GHz). In addition, these results are compared to previous results using X-ray computed tomography.

  6. Millimeter Wave Holographical Inspection of Honeycomb Composites

    Science.gov (United States)

    Case, J. T.; Kharkovsky, S.; Zoughi, R.; Steffes, G.; Hepburn, F. L.

    2008-02-01

    Multi-layered composite structures manufactured with honeycomb, foam, or balsa wood cores are finding increasing utility in a variety of aerospace, transportation, and infrastructure applications. Due to the low conductivity and inhomogeneity associated with these composites, standard nondestructive testing (NDT) methods are not always capable of inspecting their interior for various defects caused during the manufacturing process or as a result of in-service loading. On the contrary, microwave and millimeter wave NDT methods are well-suited for inspecting these structures since signals at these frequencies readily penetrate through these structures and reflect from different interior boundaries revealing the presence of a wide range of defects such as isband, delamination, moisture and oil intrusion, impact damage, etc. Millimeter wave frequency spectrum spans 30 GHz-300 GHz with corresponding wavelengths of 10-1 mm. Due to the inherent short wavelengths at these frequencies, one can produce high spatial resolution images of these composites either using real-antenna focused or synthetic-aperture focused methods. In addition, incorporation of swept-frequency in the latter method (i.e., holography) results in high-resolution three-dimensional images. This paper presents the basic steps behind producing such images at millimeter wave frequencies and the results of two honeycomb composite panels are demonstrated at Q-band (33-50 GHz). In addition, these results are compared to previous results using X-ray computed tomography.

  7. An Ultra-Wideband Millimeter-Wave Phased Array

    Science.gov (United States)

    Novak, Markus H.; Miranda, Felix A.; Volakis, John L.

    2016-01-01

    Wideband millimeter-wave arrays are of increasing importance due to their growing use in high data rate systems, including 5G communication networks. In this paper, we present a new class of ultra-wideband millimeter wave arrays that operate from nearly 20 GHz to 90 GHz. The array is based on tightly coupled dipoles. Feeding designs and fabrication challenges are presented, and a method for suppressing feed resonances is provided.

  8. Millimeter-wave interconnects for microwave-frequency quantum machines

    Science.gov (United States)

    Pechal, Marek; Safavi-Naeini, Amir H.

    2017-10-01

    Superconducting microwave circuits form a versatile platform for storing and manipulating quantum information. A major challenge to further scalability is to find approaches for connecting these systems over long distances and at high rates. One approach is to convert the quantum state of a microwave circuit to optical photons that can be transmitted over kilometers at room temperature with little loss. Many proposals for electro-optic conversion between microwave and optics use optical driving of a weak three-wave mixing nonlinearity to convert the frequency of an excitation. Residual absorption of this optical pump leads to heating, which is problematic at cryogenic temperatures. Here we propose an alternative approach where a nonlinear superconducting circuit is driven to interconvert between microwave-frequency (7 ×109 Hz) and millimeter-wave-frequency photons (3 ×1011 Hz). To understand the potential for quantum state conversion between microwave and millimeter-wave photons, we consider the driven four-wave mixing quantum dynamics of nonlinear circuits. In contrast to the linear dynamics of the driven three-wave mixing converters, the proposed four-wave mixing converter has nonlinear decoherence channels that lead to a more complex parameter space of couplings and pump powers that we map out. We consider physical realizations of such converter circuits by deriving theoretically the upper bound on the maximum obtainable nonlinear coupling between any two modes in a lossless circuit, and synthesizing an optimal circuit based on realistic materials that saturates this bound. Our proposed circuit dissipates less than 10-9 times the energy of current electro-optic converters per qubit. Finally, we outline the quantum link budget for optical, microwave, and millimeter-wave connections, showing that our approach is viable for realizing interconnected quantum processors for intracity or quantum data center environments.

  9. Considerations for millimeter wave printed antennas

    Science.gov (United States)

    Pozar, D. M.

    1983-01-01

    Calculated data are presented on the performance of printed antenna elements on substrates which may be electrically thick, as would be the case for printed antennas at millimeter wave frequencies. Printed dipoles and microstrip patch antennas on polytetrafluoroethylene (PTFE), quartz, and gallium arsenide substrates are considered. Data are given for resonant length, resonant resistance, bandwidth, loss due to surface waves, loss due to dielectric heating, and mutual coupling. Also presented is an optimization procedure for maximizing or minimizing power launched into surface waves from a multielement printed antenna array. The data are calculated by a moment method solution.

  10. Cylindrical millimeter-wave imaging technique for concealed weapon detection

    Science.gov (United States)

    Sheen, David M.; McMakin, Douglas L.; Hall, Thomas E.

    1998-03-01

    A novel cylindrical millimeter-wave imaging technique has been developed at the Pacific Northwest National Laboratory for the detection of metallic and non-metallic concealed weapons. This technique uses a vertical array of millimeter- wave antennas which is mechanically swept around a person in a cylindrical fashion. The wideband millimeter-wave data is mathematically reconstructed into a series of high- resolution images of the person being screened. Clothing is relatively transparent to millimeter-wave illumination,whereas the human body and concealed items are reflective at millimeter wavelengths. Differences in shape and reflectivity are revealed in the images and allow a human operator to detect and identify concealed weapons. A full 360 degree scan is necessary to fully inspect a person for concealed items. The millimeter-wave images can be formed into a video animation sequence in which the person appears to rotate in front of a fixed illumination source.This is s convenient method for presenting the 3D image data for analysis. This work has been fully sponsored by the FAA. An engineering prototype based on the cylindrical imaging technique is presently under development. The FAA is currently opposed to presenting the image data directly to the operator due to personal privacy concerns. A computer automated system is desired to address this problem by eliminating operator viewing of the imagery.

  11. Millimeter-wave Instrumentation Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Millimeter-wave Instrumentation Test Facility conducts basic research in propagation phenomena, remote sensing, and target signatures. The facility has a breadth...

  12. Millimeter wave imaging: a historical review

    Science.gov (United States)

    Appleby, Roger; Robertson, Duncan A.; Wikner, David

    2017-05-01

    The SPIE Passive and Active Millimeter Wave Imaging conference has provided an annual focus and forum for practitioners in the field of millimeter wave imaging for the past two decades. To celebrate the conference's twentieth anniversary we present a historical review of the evolution of millimeter wave imaging over the past twenty years. Advances in device technology play a fundamental role in imaging capability whilst system architectures have also evolved. Imaging phenomenology continues to be a crucial topic underpinning the deployment of millimeter wave imaging in diverse applications such as security, remote sensing, non-destructive testing and synthetic vision.

  13. Micro hot embossed plastic millimeter-wave systems

    Science.gov (United States)

    Cai, Ying; Sammoura, Firas; Chi, Chen-Yu; Lin, Liwei; Chiao, J.-C.

    2005-12-01

    Recently, millimeter-wave devices have been attracted more attentions in applications owing to their short wavelengths, higher resolutions, broader bandwidths and higher environmental tolerance. The great challenges of high fabrication and assembly costs, bulky volumes, and heavy weights of millimeter-wave systems call for new integrated manufacturing techniques. The hot embossing technique could address these challenges. In this paper, a review of micro plastic hot embossing was given for the fabrication of miniaturized millimeter-wave systems. The micro hot embossing on plastic materials demonstrated its advantages on significant costs, volume and weight reduction, while maintaining high performances. We have designed, fabricated and characterized a W-band rectangular waveguide and a W-band iris waveguide filter with integrated plastic flanges using micro hot embossing and selective electroplating. In this paper, we reviewed the results and discussed the design methodology in details for the micromachined components. The prototype devices showed promise for the system designs.

  14. Millimeter-Wave Receiver Concepts for 77 GHz Automotive Radar in Silicon-Germanium Technology

    CERN Document Server

    Kissinger, Dietmar

    2012-01-01

    The book presents the analysis and design of integrated automotive radar receivers in Silicon-Germanium technology, for use in complex multi-channel radar transceiver front-ends in the 77GHz frequency band. The main emphasis of the work is the realization of high-linearity and low-power modular receiver channels as well as the investigation of millimeter-wave integrated test concepts for the receiver front-end.

  15. A 31.7-GHz high linearity millimeter-wave CMOS LNA using an ultra-wideband input matching technique

    Science.gov (United States)

    Geliang, Yang; Zhigong, Wang; Zhiqun, Li; Qin, Li; Zhu, Li; Faen, Liu

    2012-12-01

    A CMOS low-noise amplifier (LNA) operating at 31.7 GHz with a low input return loss (S11) and high linearity is proposed. The wideband input matching was achieved by employing a simple LC compounded network to generate more than one S11 dip below -10 dB level. The principle of the matching circuit is analyzed and the critical factors with significant effect on the input impedance (Zin) are determined. The relationship between the input impedance and the load configuration is explored in depth, which is seldom concentrated upon previously. In addition, the noise of the input stage is modeled using a cascading matrix instead of conventional noise theory. In this way Zin and the noise figure can be calculated using one uniform formula. The linearity analysis is also performed in this paper. Finally, an LNA was designed for demonstration purposes. The measurement results show that the proposed LNA achieves a maximum power gain of 9.7 dB and an input return loss of RF CMOS process and occupies an area of 755 × 670 μm2 including pads. The whole circuit dissipates a DC power of 24 mW from one 1.3-V supply.

  16. Virtual Cathode Theory and Design of a Millimeter Wave Vircator

    Science.gov (United States)

    1983-01-01

    Power Electron and Ion Beam Research ana Technology, (Cornell University, 1977), p. 649. 76 REFERENCES (Continued) 24. J. M. Buzzi, H. J. Doucet, B... Freud , P. C. Efthimion, and A. K. Kinkead, "Study of Emission Spectrum in a Millimeter-Wave Free-Electron Laser Operating in the Collective Regime," Bull

  17. Millimeter-wave gyrotron traveling-wave tube amplifiers

    CERN Document Server

    Du, Chao-Hai

    2014-01-01

    A gyrotron traveling-wave amplifier (gyro-TWT) with the high-power and broad-band capabilities is considered as a turn-on key for next generation high-resolution radar. The book presents comprehensive theory, methods, and physics related to gyro-TWT. The most challenging problem of instability competition has been for the first time addressed in a focused and systematic way, and reported via concise states and vivid pictures. The book is likely to meet the interest of researchers and engineers in radar and microwave technology, who would like to study the gyro-TWTs and to promote its application in millimeter-wave radars.   Chao-Hai Du is a research professor, and Pu-Kun Liu is a full professor, at Peking University, Beijing, P. R. China.

  18. Passive front-ends for wideband millimeter wave electronic warfare

    Science.gov (United States)

    Jastram, Nathan Joseph

    This thesis presents the analysis, design and measurements of novel passive front ends of interest to millimeter wave electronic warfare systems. However, emerging threats in the millimeter waves (18 GHz and above) has led to a push for new systems capable of addressing these threats. At these frequencies, traditional techniques of design and fabrication are challenging due to small size, limited bandwidth and losses. The use of surface micromachining technology for wideband direction finding with multiple element antenna arrays for electronic support is demonstrated. A wideband tapered slot antenna is first designed and measured as an array element for the subsequent arrays. Both 18--36 GHz and 75--110 GHz amplitude only and amplitude/phase two element direction finding front ends are designed and measured. The design of arrays using Butler matrix and Rotman lens beamformers for greater than two element direction finding over W band and beyond using is also presented. The design of a dual polarized high power capable front end for electronic attack over an 18--45 GHz band is presented. To combine two polarizations into the same radiating aperture, an orthomode transducer (OMT) based upon a new double ridge waveguide cross section is developed. To provide greater flexibility in needed performance characteristics, several different turnstile junction matching sections are tested. A modular horn section is proposed to address flexible and ever changing operational requirements, and is designed for performance criteria such as constant gain, beamwidth, etc. A multi-section branch guide coupler and low loss Rotman lens based upon the proposed cross section are also developed. Prototyping methods for the herein designed millimeter wave electronic warfare front ends are investigated. Specifically, both printed circuit board (PCB) prototyping of micromachined systems and 3D printing of conventionally machined horns are presented. A 4--8 GHz two element array with

  19. Millimeter-Wave Atmospheric Sounder (MAS)

    Science.gov (United States)

    Hartmann, G. K.

    1988-01-01

    MAS is a remote sensing instrument for passive sounding (limb sounding) of the earth's atmosphere from the Space Shuttle. The main objective of the MAS is to study the composition and dynamic structure of the stratosphere, mesosphere, and lower thermosphere in the height range 20 to 100 km, the region known as the middle atmosphere. The MAS will be flown on the Atmospheric Laboratory for Applications and Science (ATLAS 1) NASA mission scheduled for late 1990. The Millimeter-Wave Atmospheric Sounder will provide, for the first time, information obtained simultaneously on the temperature and on ozone concentrations in the 20 to 90 km altitude region. The information will cover a large area of the globe, will have high accuracy and high vertical resolution, and will cover both day and night times. Additionally, data on the two important molecules, H2O and ClO, will also be provided.

  20. Millimeter-wave sensor image enhancement

    Science.gov (United States)

    Wilson, William J.; Suess, Helmut

    1989-01-01

    Images from an airborne, scanning radiometer operating at a frequency of 98 GHz have been analyzed. The millimeter-wave images were obtained in 1985-1986 using the JPL millimeter-wave imaging sensor. The goal of this study was to enhance the information content of these images and make their interpretation easier. A visual-interpretative approach was used for information extraction from the images. This included application of nonlinear transform techniques for noise reduction and for color, contrast, and edge enhancement. Results of using the techniques on selected millimeter-wave images are discussed.

  1. Imaging of spatial distributions of the millimeter wave intensity by using the Visible Continuum Radiation from a discharge in a Cs-Xe mixture. Part II: Demonstration of application capabilities of the technique

    Science.gov (United States)

    Gitlin, M. S.; Glyavin, M. Yu.; Fedotov, A. E.; Tsvetkov, A. I.

    2017-07-01

    The paper presents the second part of the review on a high-sensitive technique for time-resolved imaging and measurements of the 2D intensity profiles of millimeter-wave radiation by means of Visible Continuum Radiation emitted by the positive column of a medium-pressure Cs-Xe DC Discharge (VCRD method). The first part of the review was focused on the operating principles and fundamentals of this new technique [Plasma Phys. Rep. 43, 253 (2017)]. The second part of the review focuses on experiments demonstrating application of this imaging technique to measure the parameters of radiation at the output of moderate-power millimeter-wave sources. In particular, the output waveguide mode of a moderate-power W-band gyrotron with a pulsed magnetic field was identified and the relative powers of some spurious modes at the outputs of this gyrotron and a pulsed D-band orotron were evaluated. The paper also reviews applications of the VCRD technique for real-time imaging and nondestructive testing with a frame rate of higher than 10 fps by using millimeter waves. Shadow projection images of objects opaque and transparent for millimeter waves have been obtained using pulsed watt-scale millimeter waves for object illumination. Near video frame rate millimeter-wave shadowgraphy has been demonstrated. It is shown that this technique can be used for single-shot screening (including detection of concealed objects) and time-resolved imaging of time-dependent processes.

  2. Millimeter wave spectra of carbonyl cyanide ⋆

    Science.gov (United States)

    Bteich, S.B.; Tercero, B.; Cernicharo, J.; Motiyenko, R.A.; Margulès, L.; Guillemin, J.-C.

    2016-01-01

    Context More than 30 cyanide derivatives of simple organic molecules have been detected in the interstellar medium, but only one dicarbonitrile has been found and that very recently. There is still a lack of high-resolution spectroscopic data particularly for dinitriles derivatives. The carbonyl cyanide molecule is a new and interesting candidate for astrophysical detection. It could be formed by the reaction of CO and CN radicals, or by substitution of the hydrogen atom by a cyano group in cyanoformaldehyde, HC(=O)CN, that has already been detected in the interstellar medium. Aims The available data on the rotational spectrum of carbonyl cyanide is limited in terms of quantum number values and frequency range, and does not allow accurate extrapolation of the spectrum into the millimeter-wave range. To provide a firm basis for astrophysical detection of carbonyl cyanide we studied its millimeter-wave spectrum. Methods The rotational spectrum of carbonyl cyanide was measured in the frequency range 152 - 308 GHz and analyzed using Watson’s A- and S-reduction Hamiltonians. Results The ground and first excited state of v5 vibrational mode were assigned and analyzed. More than 1100 distinct frequency lines of the ground state were fitted to produce an accurate set of rotational and centrifugal distortion constants up to the eighth order. The frequency predictions based on these constants should be accurate enough for astrophysical searches in the frequency range up to 500 GHz and for transition involving energy levels with J ≤ 100 and Ka ≤ 42. Based on the results we searched for interstellar carbonyl cyanide in available observational data without success. Thus, we derived upper limits to its column density in different sources. PMID:27738349

  3. Detecting Extrasolar Planets With Millimeter-Wave Observatories

    Science.gov (United States)

    1996-01-01

    Do nearby stars have planetary systems like our own? How do such systems evolve? How common are such systems? Proposed radio observatories operating at millimeter wavelengths could start answering these questions within the next 6-10 years, according to scientists at the National Radio Astronomy Observatory (NRAO). Bryan Butler, Robert Brown, Richard Simon, Al Wootten and Darrel Emerson, all of NRAO, presented their findings today to the American Astronomical Society meeting in San Antonio, TX. Detecting planets circling other stars is a particularly difficult task, and only a few such planets have been discovered so far. In order to answer fundamental questions about planetary systems and their origin, scientists need to find and study many more extrasolar planets. According to the NRAO scientists, millimeter-wavelength observatories could provide valuable information about extrasolar planetary systems at all stages of their evolution. "With instruments planned by 2005, we could detect planets the size of Jupiter around a solar-type star out to a distance of 100 light-years," said Robert Brown, Associate Director of NRAO. "That means," he added, "that we could survey approximately 2,000 stars of different types to learn if they have planets this size." Millimeter waves occupy the portion of the electromagnetic spectrum between radio microwaves and infrared waves. Telescopes for observing at millimeter wavelengths utilize advanced electronic equipment similar to that used in radio telescopes observing at longer wavelengths. Millimeter-wave observatories offer a number of advantages in the search for extrasolar planets. Planned multi-antenna millimeter-wave telescopes can provide much higher resolving power, or ability to see fine detail, than current optical or infrared telescopes. Millimeter-wave observations would not be degraded by interference from the "zodiacal light" reflected by interplanetary dust, either in the extrasolar system or our own solar system

  4. Development of a Millimeter-Wave Beam Position and Profile Monitor for Transmission Efficiency Improvement in an ECRH System

    Directory of Open Access Journals (Sweden)

    Shimozuma T.

    2015-01-01

    Full Text Available In a high power Electron Cyclotron Resonance Heating (ECRH system, a long-distance and low-loss transmission system is required to realize effective heating of nuclear fusion-relevant plasmas. A millimeter-wave beam position and profile monitor, which can be used in a high-power, evacuated, and cooled transmission line, is proposed, designed, manufactured, and tested. The beam monitor consists of a reflector, Peltier-device array and a heat-sink. It was tested using simulated electric heater power or gyrotron output power. The data obtained from the monitor were well agreed with the heat source position and profile. The methods of data analysis and mode-content analysis of a propagating millimeter-wave in the corrugated wave-guide are proposed.

  5. High-Resolution FTIR and Millimeter-Wave Study of D 3SiF: The Ground, v3 = 1, and v6 = 1 and 2 States

    Science.gov (United States)

    Sari-Zizi, N. Ben; Najib, H.; Bürger, H.; Mkadmi, E. B.; Kisiel, Z.; Tretyakov, M. Yu; Demaison, J.; Margulès, L.; Pracna, P.

    1999-09-01

    The ν6 (555.453 cm-1), the ν3 (888.899 cm-1), and the very weak 2ν6 infrared bands (2ν∓26 1101.734 cm-1, 2ν06 1100.102 cm-1) for the 28Si species of D3SiF have been recorded with a resolution of 3.3, 2.4, and 5.0 × 10-3 cm-1, respectively. Millimeter-wave spectra up to 640 GHz of D3SiF in the ground, v3 = 1, and v6 = 1 and 2 states were measured. Ground state constants complete up to H constants including the K-dependent parameters A0, D0K, and H0K as obtained by the ν±16/2ν±26-ν±16/2ν∓26 loop method were determined by a merge of 2388 ground state combination differences with 59 rotational data. The v3 = 1 and v6 = 1 and 2 levels appear to be unperturbed intervibrationally for the J and K values that could be accessed. However, Δl = Δk = ±2 and Δl = ±2, Δk = ∓4 interactions affect the v6 = 1 level while the v6 = 2 levels undergo three interactions of Δl = Δk = ±2, Δl = ±2, Δk = ∓1 and Δl = ±4, Δk = ∓2 type. Typically, for the different bands, 2000-4000 pieces of infrared data augmented by 36-120 rotational data were fitted together. Owing to the weakness of the 2ν6 band, the body of v6 = 2 data was enlarged by energies that are deduced from the 2ν6-ν6 and ν6 bands and which span in particular high K values. Comparison with available ab initio data derived from the harmonic and anharmonic force fields is made.

  6. Millimeter wave spectra of carbonyl cyanide

    Science.gov (United States)

    Bteich, S. B.; Tercero, B.; Cernicharo, J.; Motiyenko, R. A.; Margulès, L.; Guillemin, J.-C.

    2016-07-01

    Context. More than 30 cyanide derivatives of simple organic molecules have been detected in the interstellar medium, but only one dicarbonitrile has been found and that very recently. There is still a lack of high-resolution spectroscopic data particularly for dinitriles derivatives. The carbonyl cyanide molecule is a new and interesting candidate for astrophysical detection. It could be formed by the reaction of CO and CN radicals, or by substitution of the hydrogen atom by a cyano group in cyanoformaldehyde, HC(=O)CN, that has already been detected in the interstellar medium. Aims: The available data on the rotational spectrum of carbonyl cyanide is limited in terms of quantum number values and frequency range, and does not allow accurate extrapolation of the spectrum into the millimeter-wave range. To provide a firm basis for astrophysical detection of carbonyl cyanide we studied its millimeter-wave spectrum. Methods: The rotational spectrum of carbonyl cyanide was measured in the frequency range 152-308 GHz and analyzed using Watson's A- and S-reduction Hamiltonians. Results: The ground and first excited state of v5 vibrational mode were assigned and analyzed. More than 1100 distinct frequency lines of the ground state were fitted to produce an accurate set of rotational and centrifugal distortion constants up to the eighth order. The frequency predictions based on these constants should be accurate enough for astrophysical searches in the frequency range up to 500 GHz and for transition involving energy levels with J ≤ 100 and Ka ≤ 42. Based on the results we searched for interstellar carbonyl cyanide in available observational data without success. Thus, we derived upper limits to its column density in different sources. This paper makes use of the following ALMA data: ADS/JAO.ALMA#2011.0.00009.SV. ALMA is a partnership of ESO (representing its member states), NSF (USA), and NINS (Japan) with NRC (Canada), NSC, and ASIAA (Taiwan), and KASI (Republic of

  7. Superconducting submillimeter and millimeter wave detectors

    Energy Technology Data Exchange (ETDEWEB)

    Nahum, Michael [Univ. of California, Berkeley, CA (United States)

    1992-10-20

    The series of projects described in this dissertation was stimulated by the discovery of high temperature superconductivity. Our goal was to develop useful applications which would be competitive with the current state of technology. The high-Tc microbolometer was developed into the most sensitive direct detector of millimeter waves, when operated at liquid nitrogen temperatures. The thermal boundary resistance of thin YBa2Cu307-δ films was subsequently measured and provided direct evidence for the bolometric response of high-Tc films to fast (ns) laser pulses. The low-Tc microbolometer was developed and used to make the first direct measurements of the frequency dependent optical efficiency of planar lithographed antennas. The hot-electron microbolometer was invented less than a year prior to the writing of this dissertation. Our analysis, presented here, indicates that it should be possible to attain up to two orders of magnitude higher sensitivity than that of the best available direct detectors when operated at the same temperature. The temperature readout scheme for this device could also be used to measure the intrinsic interaction between electrons and phonons in a metal with a sensitivity that is five orders of magnitude better than in previous measurements. Preliminary measurements of quasiparticle trapping effects at the interface between a metal and a superconductor are also presented.

  8. CMOS front ends for millimeter wave wireless communication systems

    CERN Document Server

    Deferm, Noël

    2015-01-01

    This book focuses on the development of circuit and system design techniques for millimeter wave wireless communication systems above 90GHz and fabricated in nanometer scale CMOS technologies. The authors demonstrate a hands-on methodology that was applied to design six different chips, in order to overcome a variety of design challenges. Behavior of both actives and passives, and how to design them to achieve high performance is discussed in detail. This book serves as a valuable reference for millimeter wave designers, working at both the transistor level and system level.   Discusses advantages and disadvantages of designing wireless mm-wave communication circuits and systems in CMOS; Analyzes the limitations and pitfalls of building mm-wave circuits in CMOS; Includes mm-wave building block and system design techniques and applies these to 6 different CMOS chips; Provides guidelines for building measurement setups to evaluate high-frequency chips.  

  9. Low Noise Amplifier Receivers from Millimeter Wave Atmospheric Remote Sensing

    Science.gov (United States)

    Kangaslahti, Pekka; Lim, Boon; Gaier, Todd; Tanner, Alan; Varonen, Mikko; Samoska, Lorene; Brown, Shannon; Lambrigsten, Bjorn; Reising, Steven; Tanabe, Jordan; hide

    2012-01-01

    We currently achieve 3.4 dB noise figure at 183GHz and 2.1 dB noise figure at 90 GHz with our MMIC low noise amplifiers (LNAs) in room temperature. These amplifiers and the receivers we have built using them made it possible to conduct highly accurate airborne measurement campaigns from the Global Hawk unmanned aerial vehicle, develop millimeter wave internally calibrated radiometers for altimeter radar path delay correction, and build prototypes of large arrays of millimeter receivers for a geostationary interferometric sounder. We use the developed millimeter wave receivers to measure temperature and humidity profiles in the atmosphere and in hurricanes as well as to characterize the path delay error in ocean topography altimetry.

  10. Millimeter-wave/infrared rectenna development at Georgia Tech

    Science.gov (United States)

    Gouker, Mark A.

    1989-01-01

    The key design issues of the Millimeter Wave/Infrared (MMW/IR) monolithic rectenna have been resolved. The work at Georgia Tech in the last year has focused on increasing the power received by the physically small MMW rectennas in order to increase the rectification efficiency. The solution to this problem is to place a focusing element on the back side of the substrate. The size of the focusing element can be adjusted to help maintain the optimum input power density not only for different power densities called for in various mission scenarios, but also for the nonuniform power density profile of a narrow EM-beam.

  11. Millimeter-Wave Integrated Circuit Design for Wireless and Radar Applications

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Krozer, Viktor; Vidkjær, Jens

    2006-01-01

    This paper describes a quadrature voltage-controlled oscillator (QVCO), frequency doubler, and sub-harmonic mixer (SHM) for a millimeter-wave (mm-wave) front-end implemented in a high-speed InP DHBT technology. The QVCO exhibits large tuning range from 38 to 47.8 GHz with an output power around -15...... from 40-50 GHz. To the authors knowledge the QVCO, frequency doubler, and SHM presents the first mm-wave implementations of these circuits in InP DHBT technology....

  12. Identifying explosives using broadband millimeter-wave imaging

    Science.gov (United States)

    Weatherall, James C.; Yam, Kevin; Barber, Jeffrey; Smith, Barry T.; Smith, Peter R.; Greca, Joseph

    2017-05-01

    Millimeter wave imaging is employed in Advanced Technology Imaging (AIT) systems to screen personnel for concealed explosives and weapons. AIT systems deployed in airports auto-detect potential threats by highlighting their location on a generic outline of a person using imaging data collected over a range of frequency. We show how the spectral information from the imaging data can be used to identify the composition of an anomalous object, in particular if it is an explosive material. The discriminative value of the technique was illustrated on military sheet explosive using millimeter-wave reflection data at frequencies 18 - 40 GHz, and commercial explosives using 2 - 18 GHz, but the free-space measurement was limited to a single horn with a large-area sample. This work extends the method to imaging data collected at high resolution with a 18 - 40 GHz imaging system. The identification of explosives is accomplished by extracting the dielectric constant from the free-space, multifrequency data. The reflection coefficient is a function of frequency because of propagation effects associated with the material's complex dielectric constant, which include interference from multiple reflections and energy loss in the sample. The dielectric constant is obtained by numerically fitting the reflection coefficient as a function of frequency to an optical model. In principal, the implementation of this technique in standoff imaging systems would allow threat assessment to be accomplished within the scope of millimeter-wave screening.

  13. Millimeter-wave receiver design for plasma diagnostics

    DEFF Research Database (Denmark)

    Leipold, Frank; Hansen, S. K.; Jacobsen, Asger Schou

    2016-01-01

    Scattered millimeter waves entering from the collective Thomson scattering diagnostic at ASDEX Upgrade fusion device are generally elliptically polarized. In order to convert the millimeter waves to linearly polarized waves (required for the detector), birefringent window assemblies (sapphire) ha...

  14. Diagnosis and Treatment of Neurological Disorders by Millimeter-Wave Stimulation

    Science.gov (United States)

    Siegel, Peter H.; Pikov, Victor

    2011-01-01

    Increasingly, millimeter waves are being employed for telecomm, radar, and imaging applications. To date in the U.S, however, very few investigations on the impact of this radiation on biological systems at the cellular level have been undertaken. In the beginning, to examine the impact of millimeter waves on cellular processes, researchers discovered that cell membrane depolarization may be triggered by low levels of integrated power at these high frequencies. Such a situation could be used to advantage in the direct stimulation of neuronal cells for applications in neuroprosthetics and diagnosing or treating neurological disorders. An experimental system was set up to directly monitor cell response on exposure to continuous-wave, fixed-frequency, millimeter-wave radiation at low and modest power levels (0.1 to 100 safe exposure standards) between 50 and 100 GHz. Two immortalized cell lines derived from lung and neuronal tissue were transfected with green fluorescent protein (GFP) that locates on the inside of the cell membrane lipid bi-layer. Oxonol dye was added to the cell medium. When membrane depolarization occurs, the oxonal bound to the outer wall of the lipid bi-layer can penetrate close to the inner wall where the GFP resides. Under fluorescent excitation (488 nm), the normally green GFP (520 nm) optical signal quenches and gives rise to a red output when the oxonol comes close enough to the GFP to excite a fluorescence resonance energy transfer (FRET) with an output at 620 nm. The presence of a strong FRET signature upon exposures of 30 seconds to 2 minutes at 5-10 milliwatts per square centimeter RF power at 50 GHz, followed by a return to the normal 520-nm GFP signal after a few minutes indicating repolarization of the membrane, indicates that low levels of RF energy may be able to trigger non-destructive membrane depolarization without direct cell contact. Such a mechanism could be used to stimulate neuronal cells in the cortex without the need for

  15. COMSTAR Millimeter-Wave Propagation Measurements,

    Science.gov (United States)

    1980-04-01

    downlink frequency. 2,3 In addition, NASA collected some simultan- eous 15- and 32-GHz attenuation data at the Rosman , North Carolina site. ATS-6...moving in azimuth and elevation when using suntrackers. Two NASA research satellites, ATS-5 and ATS-6, offered the first opportunity to utilize...communications, Proceedings of IEEE 63:1308-1331. 2. Ippolito, L.J. (1970) Millimeter-Wave Propagation Experiments Utilizing the ATS-5 Satellite, NASA

  16. The University of Texas Millimeter Wave Observatory

    Science.gov (United States)

    Vanden Bout, Paul A.; Davis, John H.; Loren, Robert B.

    2012-11-01

    This is an account of the Millimeter Wave Observatory (MWO), a 4.9 m diameter antenna facility that pioneered continuum observations of planets and spectroscopy of interstellar molecules from 1971 to 1988. The circumstances of its founding, development of its instrumentation, and major research contributions are discussed. The MWO role in training of personnel in this new field is illustrated by a listing of student and postdoctoral observers, with titles of PhD theses that included MWO data.

  17. Dielectric Antennas for Millimeter-Wave Applications.

    Science.gov (United States)

    1980-05-01

    lode 0 2 3 4I BIm )N-2 Figure 1. Norma idlclwv nubroard tprdinHpae Ik E 0 00 E-~ I(D IIU-) C)E c aC m fl -z 0)0 -00~ 0 N6 0 00 E-e 0 a) c N, E...J., September 1969, pp. 2071-2102. [10) ITANAMI, T. and SHINDOS, S., "Channel dropping filter for millimeter- wave integrated circuits," IEEE Trans...band-reject filters," IEEE Trans. Microwave Theory Tech., Vol. MTT-25, No. 12, December 1977, pp. 1134-1138. (161 KLOHN, K.L., HORN, R.E. and JACOBS, H

  18. Critical object recognition in millimeter-wave images with robustness to rotation and scale.

    Science.gov (United States)

    Mohammadzade, Hoda; Ghojogh, Benyamin; Faezi, Sina; Shabany, Mahdi

    2017-06-01

    Locating critical objects is crucial in various security applications and industries. For example, in security applications, such as in airports, these objects might be hidden or covered under shields or secret sheaths. Millimeter-wave images can be utilized to discover and recognize the critical objects out of the hidden cases without any health risk due to their non-ionizing features. However, millimeter-wave images usually have waves in and around the detected objects, making object recognition difficult. Thus, regular image processing and classification methods cannot be used for these images and additional pre-processings and classification methods should be introduced. This paper proposes a novel pre-processing method for canceling rotation and scale using principal component analysis. In addition, a two-layer classification method is introduced and utilized for recognition. Moreover, a large dataset of millimeter-wave images is collected and created for experiments. Experimental results show that a typical classification method such as support vector machines can recognize 45.5% of a type of critical objects at 34.2% false alarm rate (FAR), which is a drastically poor recognition. The same method within the proposed recognition framework achieves 92.9% recognition rate at 0.43% FAR, which indicates a highly significant improvement. The significant contribution of this work is to introduce a new method for analyzing millimeter-wave images based on machine vision and learning approaches, which is not yet widely noted in the field of millimeter-wave image analysis.

  19. 77 FR 3386 - Export and Reexport License Requirements for Certain Microwave and Millimeter Wave Electronic...

    Science.gov (United States)

    2012-01-24

    ... imposed a license requirement on exports and reexports to all destinations other than Canada of two types... mobility transistors and packaged microwave ``monolithic integrated circuits'' power amplifiers that meet... reexports to all destinations other than Canada of two types of microwave and millimeter wave electronic...

  20. Millimeter Wave Rheometry: Theory and Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Jaehun; McCloy, John S.; Crum, J. V.; Sundaram, S. K.

    2011-01-29

    A novel millimeter wave (MMW) rheometry is developed to determine the viscosity of fluid based on an unsteady film flow in an inclined plane. The method measures fringes due to MMW interference between the front and back surfaces of the fluid flowing across the field of view of a ceramic wave guide coupled to a MMW receiver. With knowledge of the dielectric constant, the interference fringe spacing is used to calculate the thickness of the fluid layer. This thickness is then transformed into the viscosity by means of a simple hydrodynamic theory. Our results show that the MMW rheometry can easily distinguish between the 30, 100, and 200 Pa•s silicone oils. The geometry of the method allows for potential industrial applications such as measuring viscosity of the flowing slag in slagging coal gasifiers. The MMW rheometry with simple modifications can be easily extended to measure important non-Newtonian fluid characteristics such as yield stress.

  1. Contact Whiskers for Millimeter Wave Diodes

    Science.gov (United States)

    Kerr, A. R.; Grange, J. A.; Lichtenberger, J. A.

    1978-01-01

    Several techniques are investigated for making short conical tips on wires (whiskers) used for contacting millimeter-wave Schottky diodes. One procedure, using a phosphoric and chromic acid etching solution (PCE), is found to give good results on 12 microns phosphor-bronze wires. Full cone angles of 60 degrees-80 degrees are consistently obtained, compared with the 15 degrees-20 degrees angles obtained with the widely used sodium hydroxide etch. Methods are also described for cleaning, increasing the tip diameter (i.e. blunting), gold plating, and testing the contact resistance of the whiskers. The effects of the whisker tip shape on the electrical resistance, inductance, and capacitance of the whiskers are studied, and examples given for typical sets of parameters.

  2. Thermoreflectance temperature measurement with millimeter wave

    Energy Technology Data Exchange (ETDEWEB)

    Pradere, C., E-mail: christophe.pradere@ensam.eu; Caumes, J.-P.; BenKhemis, S.; Palomo, E.; Batsale, J.-C. [I2M (Institut de Mécanique et d’Ingénierie de Bordeaux) UMR CNRS 5295, TREFLE Department, Esplanade des Arts et Métiers, F-33405 Talence Cedex (France); Pernot, G.; Dilhaire, S. [LOMA UMR 5798: CNRS-UB1, 351 Cours de la Libération, 33405 Talence Cedex (France)

    2014-06-15

    GigaHertz (GHz) thermoreflectance technique is developed to measure the transient temperature of metal and semiconductor materials located behind an opaque surface. The principle is based on the synchronous detection, using a commercial THz pyrometer, of a modulated millimeter wave (at 110 GHz) reflected by the sample hidden behind a shield layer. Measurements were performed on aluminum, copper, and silicon bulks hidden by a 5 cm thick Teflon plate. We report the first measurement of the thermoreflectance coefficient which exhibits a value 100 times higher at 2.8 mm radiation than those measured at visible wavelengths for both metallic and semiconductor materials. This giant thermoreflectance coefficient κ, close to 10{sup −3} K{sup −1} versus 10{sup −5} K{sup −1} for the visible domain, is very promising for future thermoreflectance applications.

  3. Thermoreflectance temperature measurement with millimeter wave

    Science.gov (United States)

    Pradere, C.; Caumes, J.-P.; BenKhemis, S.; Pernot, G.; Palomo, E.; Dilhaire, S.; Batsale, J.-C.

    2014-06-01

    GigaHertz (GHz) thermoreflectance technique is developed to measure the transient temperature of metal and semiconductor materials located behind an opaque surface. The principle is based on the synchronous detection, using a commercial THz pyrometer, of a modulated millimeter wave (at 110 GHz) reflected by the sample hidden behind a shield layer. Measurements were performed on aluminum, copper, and silicon bulks hidden by a 5 cm thick Teflon plate. We report the first measurement of the thermoreflectance coefficient which exhibits a value 100 times higher at 2.8 mm radiation than those measured at visible wavelengths for both metallic and semiconductor materials. This giant thermoreflectance coefficient κ, close to 10-3 K-1 versus 10-5 K-1 for the visible domain, is very promising for future thermoreflectance applications.

  4. A flexible millimeter-wave radio-over-fiber system for various transmission bit rate

    Science.gov (United States)

    Yang, Tao; Gao, Mingyi; Qian, Jiaqin; Zhang, Junfeng; Chen, Wei

    2017-11-01

    In this paper, we propose a flexible scheme to generate millimeter-waves (MMWs) for millimeter-wave radio-over-fiber (MMW-RoF) system. The proposed scheme has two configurations to adapt to various transmission bit rate by slightly rearranging the allocation of the system. The main structure of the system is cascaded LiNbO3 Mach-Zehnder modulators (LiNbO3-MZMs). The first configuration is cost effective method, where we utilize a wavelength division multiplexing de-multiplexer (WDM Demux) and an optical splitter (OS) to generate two unmodulated optical signals and a modulated optical signal. Each unmodulated optical signal and the modulated signal will form an optical single sideband (OSSB) modulation and therefore we simultaneously achieve a Q-band (45 GHz) and a V-band (60 GHz) MMWs in the receiver. The bit-error-ratio (BER) curves show that the power penalties of 45 GHz and 60 GHz are 0.6 dB and 1.1 dB at a BER of 1 × 10-9 with 2.5 Gb/s transmission data rate and 50 km fiber transmission distances. The second configuration can accommodate high bit rate, where few optical devices is rearranged to only generate a 60 GHz MMW with 40 Gb/s 4 quadrature amplitude modulation orthogonal frequency division multiplexing (4-QAM OFDM) signals. The power penalty is 1.1 dB at a BER of 1 × 10-9 with 50 km fiber transmission distances. Therefore, the proposed scheme can flexibly generate either two Q&V-band MMWs (45 GHz and 60 GHz) for the applications of the low data-rate transmission systems or one V-band MMW (60 GHz) for the applications of the high data-rate transmission systems.

  5. An Alternative Millimeter Wave Oscillator using a Dielectric Puck in the Whispering Gallery Mode Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A majority of millimeter wave based systems used for space exploration, communications and research, require a millimeter wave oscillator. These oscillators have...

  6. 3D Imaging Millimeter Wave Circular Synthetic Aperture Radar

    Directory of Open Access Journals (Sweden)

    Renyuan Zhang

    2017-06-01

    Full Text Available In this paper, a new millimeter wave 3D imaging radar is proposed. The user just needs to move the radar along a circular track, and high resolution 3D imaging can be generated. The proposed radar uses the movement of itself to synthesize a large aperture in both the azimuth and elevation directions. It can utilize inverse Radon transform to resolve 3D imaging. To improve the sensing result, the compressed sensing approach is further investigated. The simulation and experimental result further illustrated the design. Because a single transceiver circuit is needed, a light, affordable and high resolution 3D mmWave imaging radar is illustrated in the paper.

  7. 77 FR 1017 - Export and Reexport License Requirements for Certain Microwave and Millimeter Wave Electronic...

    Science.gov (United States)

    2012-01-09

    ... reexports to all destinations other than Canada of two types of microwave and millimeter wave electronic components. The two components are packaged high electron mobility transistors and packaged microwave... license requirement on exports and reexports to all destinations other than Canada of two types of...

  8. Millimeter wave detection of nuclear radiation: an alternative detection mechanism.

    Science.gov (United States)

    Gopalsami, N; Chien, H T; Heifetz, A; Koehl, E R; Raptis, A C

    2009-08-01

    We present a nuclear radiation detection mechanism using millimeter waves as an alternative to conventional detection. It is based on the concept that nuclear radiation causes ionization of air and that if we place a dielectric material near the radiation source, it acts as a charge accumulator of the air ions. We have found that millimeter waves can interrogate the charge cloud on the dielectric material remotely. This concept was tested with a standoff millimeter wave system by monitoring the charge levels on a cardboard tube placed in an x-ray beam.

  9. Millimeter wave detection of nuclear radiation - an alternative detection mechanism.

    Energy Technology Data Exchange (ETDEWEB)

    Gopalsami, N.; Chien, H. T.; Heifetz, A.; Koehl, E. R.; Raptis, A. C.; Nuclear Engineering Division

    2009-08-01

    We present a nuclear radiation detection mechanism using millimeter waves as an alternative to conventional detection. It is based on the concept that nuclear radiation causes ionization of air and that if we place a dielectric material near the radiation source, it acts as a charge accumulator of the air ions. We have found that millimeter waves can interrogate the charge cloud on the dielectric material remotely. This concept was tested with a standoff millimeter wave system by monitoring the charge levels on a cardboard tube placed in an x-ray beam.

  10. Millimeter wave detection of nuclear radiation: An alternative detection mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Gopalsami, N.; Chien, H. T.; Heifetz, A.; Koehl, E. R.; Raptis, A. C. [Nuclear Engineering Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    2009-08-15

    We present a nuclear radiation detection mechanism using millimeter waves as an alternative to conventional detection. It is based on the concept that nuclear radiation causes ionization of air and that if we place a dielectric material near the radiation source, it acts as a charge accumulator of the air ions. We have found that millimeter waves can interrogate the charge cloud on the dielectric material remotely. This concept was tested with a standoff millimeter wave system by monitoring the charge levels on a cardboard tube placed in an x-ray beam.

  11. Millimeter-Wave Thermal Analysis Development and Application to GEN IV Reactor Materials

    Energy Technology Data Exchange (ETDEWEB)

    Wosko, Paul; Sundram, S. K.

    2012-10-16

    New millimeter-wave thermal analysis instrumentation has been developed and studied for characterization of materials required for diverse fuel and structural needs in high temperature reactor environments such as the Next Generation Nuclear Plant (NGNP). A two-receiver 137 GHz system with orthogonal polarizations for anisotropic resolution of material properties has been implemented at MIT. The system was tested with graphite and silicon carbide specimens at temperatures up to 1300 ºC inside an electric furnace. The analytic and hardware basis for active millimeter-wave radiometry of reactor materials at high temperature has been established. Real-time, non contact measurement sensitivity to anisotropic surface emissivity and submillimeter surface displacement was demonstrated. The 137 GHz emissivity of reactor grade graphite (NBG17) from SGL Group was found to be low, ~ 5 %, in the 500 – 1200 °C range and increases by a factor of 2 to 4 with small linear grooves simulating fracturing. The low graphite emissivity would make millimeter-wave active radiometry a sensitive diagnostic of graphite changes due to environmentally induced stress fracturing, swelling, or corrosion. The silicon carbide tested from Ortek, Inc. was found to have a much higher emissivity at 137 GHz of ~90% Thin coatings of silicon carbide on reactor grade graphite supplied by SGL Group were found to be mostly transparent to millimeter-waves, increasing the 137 GHz emissivity of the coated reactor grade graphite to about ~14% at 1250 ºC.

  12. Passive millimeter wave simulation in blender

    Science.gov (United States)

    Murakowski, Maciej

    Imaging in the millimeter wave (mmW) frequency range is being explored for applications where visible or infrared (IR) imaging fails, such as through atmospheric obscurants. However, mmW imaging is still in its infancy and imager systems are still bulky, expensive, and fragile, so experiments on imaging in real-world scenarios are difficult or impossible to perform. Therefore, a simulation system capable of predicting mmW phenomenology would be valuable in determining the requirements (e.g. resolution or noise floor) of an imaging system for a particular scenario and aid in the design of such an imager. Producing simulation software for this purpose is the objective of the work described in this thesis. The 3D software package Blender was modified to simulate the images produced by a passive mmW imager, based on a Geometrical Optics approach. Simulated imagery was validated against experimental data and the software was applied to novel imaging scenarios. Additionally, a database of material properties for use in the simulation was collected.

  13. Low-Cost and High-Gain SIW Circularly Polarized Circular-Horn-Loaded Antenna for Broadband Millimeter-Wave Applications

    Directory of Open Access Journals (Sweden)

    Ming Du

    2017-09-01

    Full Text Available A wideband, low-cost and high-gain circularly polarized (CP circular-horn-loaded antenna based on substrate integrated waveguide (SIW technology operating at Ka band is presented. The proposed antenna, which is built on a single-layer substrate, consists of five parts: a short-ended SIW, a centro-symmetric wide slot, an L-shaped probe, a circular horn and a transition from SIW to air-filled rectangular waveguide for measurement. The slot is etched on the upper ground of the SIW, while the L-shaped probe for generating CP wave is printed inside the slot and connected to the SIW. A circular horn is also loaded on the surface of the SIW slot for high gain. Then, the proposed antenna with a dimension of 45×45×24.16 mm3 was fabricated and measured. The measured results show that the antenna has a wide impedance matching bandwidth of 28.6% from 30 to 40 GHz for |S11| ≤10 dB and a wide axial ratio (AR bandwidth of 22.8% from 31.5 to 39.6 GHz for AR ≤ 3 dB. The measured maximum gain is 15.6 dBi at 36 GHz with slight fluctuations over the 30–40-GHz frequency range. This kind of antenna merits low cost and easy integration with common differential circuits at the same time.

  14. Innovative systems for cultural heritage conservation. Millimeter wave application for non-invasive monitoring and treatment of works of art.

    Science.gov (United States)

    Bruno, Bisceglia; De Leo, Roberto; Pastore, Anna Pia; von Gratowski, Svetlana; Meriakri, Viatcheslav

    2011-01-01

    A novel non invasive technique and a suitable apparatus for disinfestation of artworks is introduced. Non destructive and non invasive techniques are often irreplaceable in order to preserve and restore cultural heritage objects in its structure and shape. Although many techniques are available for art and archaeological works the non invasive methods are preferred as they leave the object untouched after treatment. Environmental parameters, such as humidity, can damage culture heritage objects and also results in spring up variety of pests and other micro-organisms. Non-invasive monitoring of these damage and also disinfestation treatments and drying with help of electromagnetic waves are preferred as they keep the object untouched after treatment. Application of millimeter waves for solving this problem is discussed here. Millimeter waves have high spatial resolution and absorption in water as well as in bio-objects that are usually moist and at the same time minimal interaction with dry culture heritage objects by itself. Different phases of the microwaves treatment (MW) of artworks are described, some results are shown and discussed. Many biological forms don't survive over a certain temperature, called lethal temperature which, for most xylophages is about 53-55 degrees C, while for moulds and funguses is between 65 and 70 degrees C. In order to evaluate the management of disinfestation of works of art, incident power, temperature, exposure time were monitored. The monitoring of temperature is essential in order to prevent damages. A computer simulation allows to predict and monitor the heating process.

  15. Gram Schmidt Based Greedy Hybrid Precoding for Frequency Selective Millimeter Wave MIMO Systems

    OpenAIRE

    Alkhateeb, Ahmed; Heath Jr., Robert W.

    2016-01-01

    Hybrid analog/digital precoding allows millimeter wave MIMO systems to leverage large antenna array gains while permitting low cost and power consumption hardware. Most prior work has focused on hybrid precoding for narrow-band mmWave systems. MmWave systems, however, will likely operate on wideband channels with frequency selectivity. Therefore, this paper considers frequency selective hybrid precoding with RF beamforming vectors taken from a quantized codebook. For this system, a low-comple...

  16. First lasing of the KAERI millimeter-wave free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B.C.; Jeong, Y.U.; Cho, S.O. [Korea Atomic Energy Research Institute, Taejon (Korea, Democratic People`s Republic of)] [and others

    1995-12-31

    The millimeter-wave FEL program at KAERI aims at the generation of high-power CW laser beam with high efficiency at the wavelength of 3{approximately}10 mm for the application in plasma heating and in power beaming. In the first oscillation experiment, the FEL has lased at the wavelength of 10 mm with the pulsewidth of 10{approximately}30 {mu}s. The peak power is about 1 kW The FEL is driven by a recirculating electrostatic accelerator having tandem geometry. The energy and the current of the electron beam are 400 keV and 2 A, respectively. The FEL resonator is located in the high-voltage terminal and is composed of a helical undulator, two mesh mirrors, and a cylindrical waveguide. The parameters of the permanent-magnet helical undulator are : period = 32 mm, number of periods = 20, magnetic field = 1.3 kG. At present, with no axial guiding magnetic field only 15 % of the injected beam pass through the undulator. Transport ratio of the electron beam through the undulator is very sensitive to the injection parameters such as the diameter and the divergence of the electron beam Simulations show that, with unproved injection condition, the FEL can generate more than 50 kW of average power in CW operation. Details of the experiments, including the spectrum measurement and the recirculation of electron beam, are presented.

  17. Soft Computing Methods for Microwave and Millimeter-Wave Design Problems

    CERN Document Server

    Chauhan, Narendra; Mittal, Ankush

    2012-01-01

    The growing commercial market of Microwave/ Millimeter wave industry over the past decade has led to the explosion of interests and opportunities for the design and development of microwave components.The design of most microwave components requires the use of commercially available electromagnetic (EM) simulation tools for their analysis. In the design process, the simulations are carried out by varying the design parameters until the desired response is obtained. The optimization of design parameters by manual searching is a cumbersome and time consuming process. Soft computing methods such as Genetic Algorithm (GA), Artificial Neural Network (ANN) and Fuzzy Logic (FL) have been widely used by EM researchers for microwave design since last decade. The aim of these methods is to tolerate imprecision, uncertainty, and approximation to achieve robust and low cost solution in a small time frame.  Modeling and optimization are essential parts and powerful tools for the microwave/millimeter wave design. This boo...

  18. Low-Intensity Electromagnetic Millimeter Waves for Pain Therapy

    Directory of Open Access Journals (Sweden)

    Taras I. Usichenko

    2006-01-01

    Full Text Available Millimeter wave therapy (MWT, a non-invasive complementary therapeutic technique is claimed to possess analgesic properties. We reviewed the clinical studies describing the pain-relief effect of MWT. Medline-based search according to review criteria and evaluation of methodological quality of the retrieved studies was performed. Of 13 studies, 9 of them were randomized controlled trials (RCTs, only three studies yielded more than 3 points on the Oxford scale of methodological quality of RCTs. MWT was reported to be effective in the treatment of headache, arthritic, neuropathic and acute postoperative pain. The rapid onset of pain relief during MWT lasting hours to days after, remote to the site of exposure (acupuncture points, was the most characteristic feature in MWT application for pain relief. The most commonly used parameters of MWT were the MW frequencies between 30 and 70 GHz and power density up to 10 mW cm−2. The promising results from pilot case series studies and small-size RCTs for analgesic/hypoalgesic effects of MWT should be verified in large-scale RCTs on the effectiveness of this treatment method.

  19. Enhanced Next Generation Millimeter-Wave Multicarrier System with Generalized Frequency Division Multiplexing

    Directory of Open Access Journals (Sweden)

    Hidekazu Shimodaira

    2016-01-01

    Full Text Available Orthogonal Frequency Division Multiplexing (OFDM is a popular multicarrier technique used to attain high spectral efficiencies. It also has other advantages such as multipath tolerance and ease of implementation. However, OFDM based systems suffer from high Peak-to-Average Power Ratio (PAPR problem. Because of the nonlinearity of the power amplifiers, the high PAPR causes significant distortion in the transmitted signal for millimeter-wave (mmWave systems. To alleviate the high PAPR problem, this paper utilizes Generalized Frequency Division Multiplexing (GFDM which can achieve high spectral efficiency as well as low PAPR. In this paper, we show the performance of GFDM using the IEEE 802.11ad multicarrier frame structures. IEEE 802.11ad is considered one of the most successful industry standards utilizing unlicensed mmWave frequency band. In addition, this paper indicates the feasibility of using GFDM for the future standards such as IEEE 802.11ay. This paper studies the performance improvements in terms of PAPR reduction for GFDM. Based on the performance results, the optimal numbers of subcarriers and subsymbols are calculated for PAPR reduction while minimizing the Bit Error Rate (BER performance degradation. Moreover, transmitter side ICI (Intercarrier Interference reduction is introduced to reduce the receiver load.

  20. Millimeter Wave Radiations Affect Membrane Hydration in Phosphatidylcholine Vesicles

    Directory of Open Access Journals (Sweden)

    Giuseppe Chidichimo

    2013-07-01

    Full Text Available A clear understanding of the response of biological systems to millimeter waves exposure is of increasing interest for the scientific community due to the recent convincing use of these radiations in the ultrafast wireless communications. Here we report a deuterium nuclear magnetic resonance spectroscopy (2H-NMR investigation on the effects of millimeter waves in the 53–78 GHz range on phosphocholine bio-mimetic membranes. Millimeter waves significantly affect the polar interface of the membrane causing a decrease of the heavy water quadrupole splitting. This effect is as important as inducing the transition from the fluid to the gel phase when the membrane exposure occurs in the neighborhood of the transition point. On the molecular level, the above effect can be well explained by membrane dehydration induced by the radiation.

  1. Millimeter-wave spectra of the Jovian planets

    Science.gov (United States)

    Joiner, Joanna; Steffes, Paul G.

    1991-01-01

    The millimeter wave portion of the electromagnetic spectrum is critical for understanding the subcloud atmospheric structure of the Jovian planets (Jupiter, Saturn, Uranus, and Neptune). This research utilizes a combination of laboratory measurements, computer modeling, and radio astronomical observation in order to obtain a better understanding of the millimeter-wave spectra of the Jovian planets. The pressure broadened absorption from gaseous ammonia (NH3) and hydrogen sulfide (H2S) was measured in the laboratory under simulated conditions for the Jovian atmospheres. Researchers developed new formalisms for computing the absorptivity of gaseous NH3 and H2S based on their laboratory measurements. They developed a radiative transfer and thermochemical model to predict the abundance and distribution of absorbing constituents in the Jovian atmospheres. They used the model to compute the millimeter wave emission from the Jovian planets.

  2. Near-Field Cross Section Imaging of Wideband Millimeter Wave

    Directory of Open Access Journals (Sweden)

    Kan Yingzhi

    2016-01-01

    Full Text Available Near-field millimeter wave imaging has been a hot topic recent years for its importance applications in the area of anti-terrorism. The penetrating characteristic of millimeter wave is of significant importance to security, such as the concealed weapons detection, ground-penetrating radar imaging, through-barrier imaging and so on. Cross section imaging is a basic aspect for near-field millimeter wave imaging, which includes antenna array distribution and wideband signal processing. This paper utilizes back projection method in space area to realize ultra-band nearfield cross section imaging. We induce two dimensional direction integral formulas to obtain the reconstruction image of the near-field imaging area, and the simulation results validate the effectiveness of this imaging algorithm.

  3. Review on Millimeter Wave Antennas- Potential Candidate for 5G Enabled Applications

    Directory of Open Access Journals (Sweden)

    M. A. Matin

    2016-12-01

    Full Text Available The millimeter wave (mmWave band is considered as the potential candidate for high speed communication services in 5G networks due to its huge bandwidth. Moreover, mmWave frequencies lead to miniaturization of RF front end including antennas. In this article, we provide an overview of recent research achievements of millimeter-wave antenna design along with the design considerations for compact antennas and antennas in package/on chip, mostly in the 60 GHz band is described along with their inherent benefits and challenges. A comparative analysis of various designs is also presented. The antennas with wide bandwidth, high-gain, compact size and low profile with easiness of integration in-package or on-chip with other components are required for 5G enabled applications.

  4. The investigation of using 5G millimeter-wave communications links for environmental monitoring

    Science.gov (United States)

    Han, Congzheng

    2017-04-01

    There has been significantly increasing recognition that millimeter waves from 30 GHz to 300 GHz as carriers for future 5G cellular networks. This is good for high speed, line-of-sight communication, potentially using very densely deployed infrastructure involving many small cells. High resolution, continuous and accurate monitoring of environmental conditions, such as rainfall and water vapor are of great important to meteorology, hydrology (e.g. flood warning), agriculture, environmental policy (e.g. pollution regulation) and weather forecasting. We have built a 28GHz measurement link at our research institute in central Beijing, China. This work will study the potential of using millimeter wave based wireless links to monitor environmental conditions including rainfall and water vapor.

  5. Microwave and millimeter-wave remote sensing for security applications

    CERN Document Server

    Nanzer, Jeffrey

    2012-01-01

    Microwave and millimeter-wave remote sensing techniques are fast becoming a necessity in many aspects of security as detection and classification of objects or intruders becomes more difficult. This groundbreaking resource offers you expert guidance in this burgeoning area. It provides you with a thorough treatment of the principles of microwave and millimeter-wave remote sensing for security applications, as well as practical coverage of the design of radiometer, radar, and imaging systems. You learn how to design active and passive sensors for intruder detection, concealed object detection,

  6. A Multiband OFDMA Heterogeneous Network for Millimeter Wave 5G Wireless Applications

    OpenAIRE

    Niknam, Solmaz; Nasir, Ali A.; Mehrpouyan, Hani; Natarajan, Balasubramaniam

    2016-01-01

    Emerging fifth generation (5G) wireless networks require massive bandwidth in higher frequency bands, extreme network densities, and flexibility of supporting multiple wireless technologies in order to provide higher data rates and seamless coverage. It is expected that utilization of the large bandwidth in the millimeter-wave (mmWave) band and deployment of heterogeneous networks (HetNets) will help address the data rate requirements of 5G networks. However, high pathloss and shadowing in th...

  7. Optical Synthesis of Terahertz and Millimeter-Wave Frequencies with Discrete Mode Diode Lasers

    CERN Document Server

    O'Brien, Stephen; Bitauld, David; Brandonisio, Nicola; Amann, Andreas; Phelan, Richard; Kelly, Brian; O'Gorman, James

    2010-01-01

    It is shown that optical synthesis of terahertz and millimeter-wave frequencies can be achieved using two-mode and mode-locked discrete mode diode lasers. These edge-emitting devices incorporate a spatially varying refractive index profile which is designed according to the spectral output desired of the laser. We first demonstrate a device which supports two primary modes simultaneously with high spectral purity. In this case sinusoidal modulation of the optical intensity at terahertz frequencies can be obtained. Cross saturation of the material gain in quantum well lasers prevents simultaneous lasing of two modes with spacings in the millimeter-wave region. We show finally that by mode-locking of devices that are designed to support a minimal set of four primary modes, we obtain a sinusoidal modulation of the optical intensity in this frequency region.

  8. Millimeter wave radiometer installation in Río Gallegos, southern Argentina

    Science.gov (United States)

    Orte, P. F.; Salvador, J.; Wolfram, E.; D'Elia, R.; Nagahama, T.; Kojima, Y.; Tanada, R.; Kuwahara, T.; Morihira, A.; Quel, E.; Mizuno, A.

    2011-05-01

    With the aim of contribution to the study of atmospheric ozone layer, a new sensitive radiometer for atmospheric minor constituents has been installed in the Observatorio Atmosférico de la Patagonia Austral, División LIDAR, CEILAP (CITEDEF-CONICET), in October 2010. This observatory is established in the city of Rio Gallegos (51° 36' S, 69° 19' W), Argentina, close to the spring ozone hole. The millimeter wave radiometer was developed in STEL (Solar Terrestrial Environment Laboratory), Nagoya University, Japan. This passive remote sensing instrument is able to measure the ozone (O3) amount in the high stratosphere and mesosphere continuously and automatically with a high time resolution. The millimeter wave radiometer ozone profiles will be supplemented with the ozone profiles obtained from the DIAL system existent in the observatory. The millimeter wave radiometer is based on the spectral signal detection from the atmosphere due to the molecular rotational transition of molecules under study. The operation is based on a superheterodyne system which uses a Superconductor-Insulator-Superconductor (SIS) mixer receiver operating at 203.6GHz. The SIS mixer junction consists of a sandwich structure of Nb/AlOx/Nb, and is cooled to 4.2K with a closed cycle He-gas refrigerator. Two additional heterodyne-mixed stages are realized with the aim to shift the measured spectral line until a frequency around of 500 MHz. A FFT (Fast Fourier Transform) spectrometer system is used as a back end. The aims of this work are to show the potential of the millimeter wave radiometer installed in the subpolar latitudes close to the polar ozone hole and to present the preliminary result of the first measurements.

  9. Millimeter wave VAlidation STandard (mm-VAST) antenna. Abstract

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.

    This document outlines the background, objectives and the main results of the project “Millimeter wave VAlidation STandard (mm-VAST) antenna” completed by the Technical University of Denmark (DTU) in collaboration with Danish company TICRA for the European Space Agency (ESA) under ESA contract no...

  10. Digitally assisted analog beamforming for millimeter-wave communication

    NARCIS (Netherlands)

    Kokkeler, Andre B.J.; Smit, Gerardus Johannes Maria

    2015-01-01

    The paper addresses the research question on how digital beamsteering algorithms can be combined with analog beamforming in the context of millimeter-wave communication for next generation (5G) cellular systems. Key is the use of coarse quantisation of the individual antenna signals next to the

  11. multiband millimeter wave t-shaped antenna with optimized patch ...

    African Journals Online (AJOL)

    Adamu Halilu

    This paper proposed a simple T-shaped patch antenna for millimeter waveband frequency operation. Millimeter wave is a frequency ranges between 30GHz to 300GHz in an electromagnetic spectrum. The proposed antenna consists of T- shape radiating patch mounted on rectangular substrate (FR4-4) and microstrip line ...

  12. Broadband notch filter design for millimeter-wave plasma diagnostics

    DEFF Research Database (Denmark)

    Furtula, Vedran; Michelsen, Poul; Leipold, Frank

    2010-01-01

    Notch filters are integrated in plasma diagnostic systems to protect millimeter-wave receivers from intensive stray radiation. Here we present a design of a notch filter with a center frequency of 140 GHz, a rejection bandwidth of ∼ 900 MHz, and a typical insertion loss below 2 dB in the passband...

  13. Millimeter wave VAlidation STandard (mm-VAST) antenna

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.

    This document summarizes the main results of the project “Millimeter wave VAlidation STandard (mm-VAST) antenna” completed by the Technical University of Denmark (DTU) in collaboration with Danish company TICRA for the European Space Agency (ESA) under ESA contract no. 4000109866/13/NL/MH....

  14. Spatial Stationarity of Ultrawideband and Millimeter Wave Radio Channels

    DEFF Research Database (Denmark)

    Yi, Tan; Nielsen, Jesper Ødum; Pedersen, Gert F.

    2016-01-01

    For radio channels with broad bandwidth resource, such as those often used for ultrawideband (UWB) and millimeter wave (mmwave) systems, the Wide-Sense Stationary Uncorrelated Scattering (WSSUS) and spatial stationary assumptions are more critical than typical cellular channels with very limited...

  15. RF Performance of Layer-Structured Broadband Passive Millimeter-Wave Imaging System

    Directory of Open Access Journals (Sweden)

    Kunio Sakakibara

    2016-01-01

    Full Text Available Low profile and simple configuration are advantageous for RF module in passive millimeter-wave imaging system. High sensitivity over broad operation bandwidth is also necessary to detect right information from weak signal. We propose a broadband layer-structured module with low profile, simple structure, and ease of manufacture. This module is composed of a lens antenna and a detector module that consists of a detector circuit and a broadband microstrip-to-waveguide transition. The module forms a layer structure as a printed substrate with detector circuit is fixed between two metal plates with horn antennas and back-short waveguides. We developed a broadband passive millimeter-wave imaging module composed of a lens antenna and a detector module in this work. The gain and the antenna efficiency were measured, and the broadband operation was observed for the lens antenna. For the detector module, peak sensitivity was 8100 V/W. Furthermore, the detector module recognized a difference in the absorber’s temperature. The designs of the lens antenna and the detector module are presented and the RF performances of these components are reported. Finally, passive millimeter-wave imaging of a car, a human, and a metal plate in clothes is demonstrated in this paper.

  16. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network.

    Science.gov (United States)

    Lin, Kai; Wang, Di; Hu, Long

    2016-07-01

    With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC). The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S) evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods.

  17. Millimeter-wave Interferometric Synthetic Aperture Radar Data Imaging Based on Terrain Surface Projection

    Directory of Open Access Journals (Sweden)

    Wei Shun-jun

    2015-02-01

    Full Text Available Millimeter-wave Interferometric Synthetic Aperture Radar (InSAR has smaller size, lower weight, and higher resolution compared with other bands. Thus, it has become a hot research topic. However, owing to its shorter wavelength, millimeter-wave InSAR data processing requires high-precision measurements of platform motion. For nonideal trajectories, traditional methods face difficulties in echo imaging and interferogram extraction. In addition, existing methods mainly produce SAR images based on plane projection. When the terrain changes abruptly, these methods may cause strong interferometric phase unwrapping and geometric distortion in SAR images. To overcome the abovementioned disadvantages of conventional methods in millimeter-wave InSAR imaging, an approach based on terrain surface projection is proposed. The echoes of different antennas are projected on the same terrain surface space for data imaging and interferogram extraction. In addition, the relation between terrain elevation and interferometric phase is derived. Simulations and experimental results verify the effectiveness of the proposed method; furthermore, the proposed approach improves the precision of interferometric phase extraction in complex motion conditions, while minimizing geometric distortion and phase wrapping in rough terrain, which is more conducive to terrain description and elevation inversion.

  18. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network

    Directory of Open Access Journals (Sweden)

    Kai Lin

    2016-07-01

    Full Text Available With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC. The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods.

  19. A Tutorial on Optical Feeding of Millimeter-Wave Phased Array Antennas for Communication Applications

    Directory of Open Access Journals (Sweden)

    Ivan Aldaya

    2015-01-01

    Full Text Available Given the interference avoidance capacity, high gain, and dynamical reconfigurability, phased array antennas (PAAs have emerged as a key enabling technology for future broadband mobile applications. This is especially important at millimeter-wave (mm-wave frequencies, where the high power consumption and significant path loss impose serious range constraints. However, at mm-wave frequencies the phase and amplitude control of the feeding currents of the PAA elements is not a trivial issue because electrical beamforming requires bulky devices and exhibits relatively narrow bandwidth. In order to overcome these limitations, different optical beamforming architectures have been presented. In this paper we review the basic principles of phased arrays and identify the main challenges, that is, integration of high-speed photodetectors with antenna elements and the efficient optical control of both amplitude and phase of the feeding current. After presenting the most important solutions found in the literature, we analyze the impact of the different noise sources on the PAA performance, giving some guidelines for the design of optically fed PAAs.

  20. GPM GROUND VALIDATION CONICAL SCANNING MILLIMETER-WAVE IMAGING RADIOMETER (COSMIR) GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Conical Scanning Millimeter-wave Imaging Radiometer (COSMIR) GCPEx dataset used the Conical Scanning Millimeter-wave Imaging Radiometer...

  1. Harmonic analysis approach to the 'TunneLadder' - A modified Karp circuit for millimeter-wave TWTA's

    Science.gov (United States)

    Kosmahl, H. G.; Palmer, R. W.

    1982-05-01

    A field approach to the summed harmonic analysis of the TunneLadder structure, or modified forward-wave Karp circuit, is developed by combining TM(01) and TE(11) modes. Results suggest the suitability of this structure as a high-impedance, about 1-% bandwidth circuit, millimeter-wave forward-wave-type amplifier that is voltage tunable over about a 5-% frequency range and has excellent power handling ability. Theory gives good agreement with experimental results obtained by Karp in omega-beta dispersion and predicts qualitatively the appearances of the antisymmetric mode discussed and of the so called Hightron mode that was discussed earlier in White, Enderby and Birdsall (1964), and Enderby (1964), in addition to the desired symmetric mode.

  2. Harmonic analysis approach to the 'TunneLadder' - A modified Karp circuit for millimeter-wave TWTA's

    Science.gov (United States)

    Kosmahl, H. G.; Palmer, R. W.

    1982-01-01

    A field approach to the summed harmonic analysis of the TunneLadder structure, or modified forward-wave Karp circuit, is developed by combining TM(01) and TE(11) modes. Results suggest the suitability of this structure as a high-impedance, about 1-% bandwidth circuit, millimeter-wave forward-wave-type amplifier that is voltage tunable over about a 5-% frequency range and has excellent power handling ability. Theory gives good agreement with experimental results obtained by Karp in omega-beta dispersion and predicts qualitatively the appearances of the antisymmetric mode discussed and of the so called Hightron mode that was discussed earlier in White, Enderby and Birdsall (1964), and Enderby (1964), in addition to the desired symmetric mode.

  3. Peering inside microplasmas sustained by microwaves, millimeter waves and beyond

    Science.gov (United States)

    Hopwood, Jeffrey

    2016-09-01

    Atmospheric microplasmas are experimentally investigated over a range of excitation frequency from 0.5 to 12 GHz. A validated fluid model correctly predicts the measured electron density in this band of operation. This model is then extended to predict plasma behavior up to 0.4 THz. At constant power (0.25 W), the central electron density increases to 5x1014 cm-3 as the microwave frequency increases toward the electron energy dissipation frequency of 5 GHz (in argon). Above 5 GHz, the argon plasma density remains approximately constant, but the electrode voltage decreases to less than 5 volts in amplitude. This is remarkable in that the microwave potential is less than the excitation potential of argon. In the millimeter wave band, we observe series resonance between the plasma inductance and sheath capacitance at 30 GHz. The parallel resonance results in strong electron oscillation within the microplasma at the position where the electron plasma frequency is equal to the excitation frequency ( 200 GHz). Crossing resonance boundaries changes the nature of the microplasma impedance between capacitive, resistive, and inductive. In addition to linear behavior, we also present models and measurements of microplasma nonlinearity. Nonlinearity generates harmonic plasma currents and is due primarily to dynamic sheath expansion and electron conduction currents. In total, the microplasma provides a rich variety of electromagnetic behaviors that can be incorporated into plasma-reconfigurable metamaterials and photonic crystals. This work was supported by the Air Force Office of Scientific Research under Award No. FA9550-14-10317 with Dr. Mitat Birkan as the program manager.

  4. Design of polarizers for a mega-watt long-pulse millimeter-wave transmission line on the large helical device.

    Science.gov (United States)

    Ii, T; Kubo, S; Shimozuma, T; Kobayashi, S; Okada, K; Yoshimura, Y; Igami, H; Takahashi, H; Ito, S; Mizuno, Y; Okada, K; Makino, R; Kobayashi, K; Goto, Y; Mutoh, T

    2015-02-01

    The polarizer is one of the critical components in a high-power millimeter-wave transmission line. It requires full and highly efficient coverage of any polarization states, high-power tolerance, and low-loss feature. Polarizers with rounded shape at the edge of the periodic groove surface are designed and fabricated by the machining process for a mega-watt long-pulse millimeter-wave transmission line of the electron cyclotron resonance heating system in the large helical device. The groove shape of λ/8- and λ/4-type polarizers for an 82.7 GHz transmission line is optimally designed in an integral method developed in the vector theories of diffraction gratings so that the efficiency to realize any polarization state can be maximized. The dependence of the polarization states on the combination of the two polarizer rotation angles (Φλ/8, Φλ/4) is examined experimentally in a low-power test with the newly developed polarization monitor. The results show that the measured polarization characteristics are in good agreement with the calculated ones.

  5. Effect of acute millimeter wave exposure on dopamine metabolism of NGF-treated PC12 cells

    Science.gov (United States)

    Haas, Alexis J.; Le Page, Yann; Zhadobov, Maxim; Sauleau, Ronan; Saligaut, Christian

    2017-01-01

    Abstract Several forthcoming wireless telecommunication systems will use electromagnetic frequencies at millimeter waves (MMWs), and technologies developed around the 60-GHz band will soon know a widespread distribution. Free nerve endings within the skin have been suggested to be the targets of MMW therapy which has been used in the former Soviet Union. So far, no studies have assessed the impact of MMW exposure on neuronal metabolism. Here, we investigated the effects of a 24-h MMW exposure at 60.4 GHz, with an incident power density (IPD) of 5 mW/cm², on the dopaminergic turnover of NGF-treated PC12 cells. After MMW exposure, both intracellular and extracellular contents of dopamine (DA) and 3,4-dihydroxyphenylacetic acid (DOPAC) were studied using high performance liquid chromatography. Impact of exposure on the dopamine transporter (DAT) expression was also assessed by immunocytochemistry. We analyzed the dopamine turnover by assessing the ratio of DOPAC to DA, and measuring DOPAC accumulation in the medium. Neither dopamine turnover nor DAT protein expression level were impacted by MMW exposure. However, extracellular accumulation of DOPAC was found to be slightly increased, but not significantly. This result was related to the thermal effect, and overall, no evidence of non-thermal effects of MMW exposure were observed on dopamine metabolism. PMID:28339776

  6. REMOTE DETECTION OF RADIOACTIVE PLUMES USING MILLIMETER WAVE TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    Barnowski, R.; Chien; H.; Gopalsami, N.

    2009-01-01

    The reprocessing of spent nuclear fuel, a common method for manufacturing weapons-grade special nuclear materials, is accompanied by the release of fi ssion products trapped within the fuel. One of these fi ssion products is a radioactive isotope of Krypton (Kr-85); a pure β- emitter with a half-life of 10.72 years. Due to its chemical neutrality and relatively long half life, nearly all of the Kr-85 is released into the surrounding air during reprocessing, resulting in a concentration of Kr-85 near the source that is several orders of magnitude higher than the typical background (atmospheric) concentrations. This high concentration of Kr-85 is accompanied by a proportionately high increase in air ionization due to the release of beta radiation from Kr-85 decay. Millimeter wave (MMW) sensing technology can be used to detect the presence of Kr-85 induced plumes since a high concentration of ions in the air increases the radar cross section due to a combination of atmospheric phenomena. Possible applications for this technology include the remote sensing of reprocessing activities across national borders bolstering global anti-proliferation initiatives. The feasibility of using MMW radar technology to uniquely detect the presence of Kr-85 can be tested using commercial ion generators or sealed radioactive sources in the laboratory. In this paper we describe our work to derive an ion dispersion model that will describe the spatial distribution of ions from Kr-85 and other common lab sources. The types and energies of radiation emitted by isotopes Co-60 and Cs-137 were researched, and these parameters were incorporated into these dispersion models. Our results can be compared with the results of MMW detection experiments in order to quantify the relationship between radar cross section and air ionization as well as to further calibrate the MMW detection equipment.

  7. Infrared and millimeter waves v.14 millimeter components and techniques, pt.V

    CERN Document Server

    Button, Kenneth J

    1985-01-01

    Infrared and Millimeter Waves, Volume 14: Millimeter Components and Techniques, Part V is concerned with millimeter-wave guided propagation and integrated circuits. In addition to millimeter-wave planar integrated circuits and subsystems, this book covers transducer configurations and integrated-circuit techniques, antenna arrays, optoelectronic devices, and tunable gyrotrons. Millimeter-wave gallium arsenide (GaAs) IMPATT diodes are also discussed. This monograph is comprised of six chapters and begins with a description of millimeter-wave integrated-circuit transducers, focusing on vario

  8. Deep Geothermal Drilling Using Millimeter Wave Technology. Final Technical Research Report

    Energy Technology Data Exchange (ETDEWEB)

    Oglesby, Kenneth [Impact Technologies LLC, Tulsa, OK (United States); Woskov, Paul [MIT (Massachusetts Inst. of Technology), Cambridge, MA (United States); Einstein, Herbert [MIT (Massachusetts Inst. of Technology), Cambridge, MA (United States); Livesay, Bill [MIT (Massachusetts Inst. of Technology), Cambridge, MA (United States)

    2014-12-30

    Conventional drilling methods are very mature, but still have difficulty drilling through very deep,very hard and hot rocks for geothermal, nuclear waste entombment and oil and gas applications.This project demonstrated the capabilities of utilizing only high energy beams to drill such rocks,commonly called ‘Direct Energy Drilling’, which has been the dream of industry since the invention of the laser in the 1960s. A new region of the electromagnetic spectrum, millimeter wave (MMW) wavelengths at 30-300 giga-hertz (GHz) frequency was used to accomplish this feat. To demonstrate MMW beam drilling capabilities a lab bench waveguide delivery, monitoring and instrument system was designed, built and tested around an existing (but non-optimal) 28 GHz frequency, 10 kilowatt (kW) gyrotron. Low waveguide efficiency, plasma generation and reflected power challenges were overcome. Real-time monitoring of the drilling process was also demonstrated. Then the technical capability of using only high power intense millimeter waves to melt (with some vaporization) four different rock types (granite, basalt, sandstone, limestone) was demonstrated through 36 bench tests. Full bore drilling up to 2” diameter (size limited by the available MMW power) was demonstrated through granite and basalt samples. The project also demonstrated that MMW beam transmission losses through high temperature (260°C, 500oF), high pressure (34.5 MPa, 5000 psi) nitrogen gas was below the error range of the meter long path length test equipment and instruments utilized. To refine those transmission losses closer, to allow extrapolation to very great distances, will require a new test cell design and higher sensitivity instruments. All rock samples subjected to high peak temperature by MMW beams developed fractures due to thermal stresses, although the peak temperature was thermodynamically limited by radiative losses. Therefore, this limited drill rate and rock strength data were not able to be

  9. Millimeter-wave Signature of Strange Matter Stars

    OpenAIRE

    Broderick, J. J.; Herrin, E. T.; Krisher, T. P.; Morgan, D L; Rosenbaum, D. C.; Sher, M.; Teplitz, V. L.

    1997-01-01

    One of the most important questions in the study of compact objects is the nature of pulsars, including whether they consist of neutron star matter or strange quark matter (SQM). However, few mechanisms for distinguishing between these two possibilities have been proposed. The purpose of this Letter is to show that a strange star (one made of SQM) will have a vibratory mode with an oscillation frequency of approximately 250 GHz (millimeter wave). This mode corresponds to motion of the center ...

  10. Planar Millimeter-Wave Antennas: A Comparative Study

    Directory of Open Access Journals (Sweden)

    K. Pitra

    2011-04-01

    Full Text Available The paper describes the design and the experimental verification of three types of wideband antennas. Attention is turned to the bow-tie antenna, the Vivaldi antenna and the spiral antenna designed for the operation at millimeter waves. Bandwidth, input impedance, gain, and directivity pattern are the investigated parameters. Antennas are compared considering computer simulations in CST Microwave Studio and measured data.

  11. WDM Phase-Modulated Millimeter-Wave Fiber Systems

    DEFF Research Database (Denmark)

    Yu, Xianbin; Prince, Kamau; Gibbon, Timothy Braidwood

    2012-01-01

    This chapter presents a computer simulation case study of two typical WDM phase-modulated millimeter-wave systems. The phase-modulated 60 GHz fiber multi-channel transmission systems employ single sideband (SSB) and double sideband subcarrier modulation (DSB-SC) schemes and present one...... of the latest research efforts in the rapidly emerging Radio-over-Fiber (RoF) application space for in-house access networks....

  12. Microfabrication Techniques for Millimeter Wave Vacuum Electronics

    Science.gov (United States)

    2015-01-01

    Figure 4. (a) 220 GHz TWT circuit fabricated by UV-LIGA, (b) completed compact tube, (c) small signal gain, (d) power drive curve achieving 63 W...output. Demonstration A 220 GHz traveling wave tube ( TWT ) circuit was created using the UV-LIGA method with a photomask in two layers with the...gain TWTs . Acknowledgements This work was funded by the U.S. Office of Naval Research. The authors wish to thank R. E. Myers, B. S. Albright, and

  13. Design and Fabrication of Millimeter Wave Hexagonal Nano-Ferrite Circulator on Silicon CMOS Substrate

    Science.gov (United States)

    Oukacha, Hassan

    The rapid advancement of Complementary Metal Oxide Semiconductor (CMOS) technology has formed the backbone of the modern computing revolution enabling the development of computationally intensive electronic devices that are smaller, faster, less expensive, and consume less power. This well-established technology has transformed the mobile computing and communications industries by providing high levels of system integration on a single substrate, high reliability and low manufacturing cost. The driving force behind this computing revolution is the scaling of semiconductor devices to smaller geometries which has resulted in faster switching speeds and the promise of replacing traditional, bulky radio frequency (RF) components with miniaturized devices. Such devices play an important role in our society enabling ubiquitous computing and on-demand data access. This thesis presents the design and development of a magnetic circulator component in a standard 180 nm CMOS process. The design approach involves integration of nanoscale ferrite materials on a CMOS chip to avoid using bulky magnetic materials employed in conventional circulators. This device constitutes the next generation broadband millimeter-wave circulator integrated in CMOS using ferrite materials operating in the 60GHz frequency band. The unlicensed ultra-high frequency spectrum around 60GHz offers many benefits: very high immunity to interference, high security, and frequency re-use. Results of both simulations and measurements are presented in this thesis. The presented results show the benefits of this technique and the potential that it has in incorporating a complete system-on-chip (SoC) that includes low noise amplifier, power amplier, and antenna. This system-on-chip can be used in the same applications where the conventional circulator has been employed, including communication systems, radar systems, navigation and air traffic control, and military equipment. This set of applications of

  14. Microfabricated Millimeter-Wave Antenna Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal addresses the need for an antenna technology platform that meets the requirements of high-performance materials, exacting dimensional tolerances, and...

  15. Caching Meets Millimeter Wave Communications for Enhanced Mobility Management in 5G Networks

    OpenAIRE

    Semiari, Omid; Saad, Walid; Bennis, Mehdi; Maham, Behrouz

    2017-01-01

    One of the most promising approaches to overcome the uncertainty and dynamic channel variations of millimeter wave (mmW) communications is to deploy dual-mode base stations that integrate both mmW and microwave ($\\mu$W) frequencies. If properly designed, such dual-mode base stations can enhance mobility and handover in highly mobile wireless environments. In this paper, a novel approach for analyzing and managing mobility in joint $\\mu$W-mmW networks is proposed. The proposed approach leverag...

  16. Liquid Crystal-Reconfigurable Antenna Concepts for Space Applications at Microwave and Millimeter Waves

    Directory of Open Access Journals (Sweden)

    A. Gaebler

    2009-01-01

    Full Text Available Novel approaches of tunable devices for millimeter wave applications based on liquid crystal (LC are presented. In the first part of the paper, a novel concept of a tunable LC phase shifter realized in Low Temperature Cofired Ceramics technology is shown while the second part of the paper deals with a tunable high-gain antenna based on an LC tunable reflectarray. The reflectarray features continuously beam scanning in between ±25∘. Also first investigations on radiation hardness of LCs are carried out, indicating that LCs might be suitable for space applications.

  17. An Off-Grid Turbo Channel Estimation Algorithm for Millimeter Wave Communications

    Directory of Open Access Journals (Sweden)

    Lingyi Han

    2016-09-01

    Full Text Available The bandwidth shortage has motivated the exploration of the millimeter wave (mmWave frequency spectrum for future communication networks. To compensate for the severe propagation attenuation in the mmWave band, massive antenna arrays can be adopted at both the transmitter and receiver to provide large array gains via directional beamforming. To achieve such array gains, channel estimation (CE with high resolution and low latency is of great importance for mmWave communications. However, classic super-resolution subspace CE methods such as multiple signal classification (MUSIC and estimation of signal parameters via rotation invariant technique (ESPRIT cannot be applied here due to RF chain constraints. In this paper, an enhanced CE algorithm is developed for the off-grid problem when quantizing the angles of mmWave channel in the spatial domain where off-grid problem refers to the scenario that angles do not lie on the quantization grids with high probability, and it results in power leakage and severe reduction of the CE performance. A new model is first proposed to formulate the off-grid problem. The new model divides the continuously-distributed angle into a quantized discrete grid part, referred to as the integral grid angle, and an offset part, termed fractional off-grid angle. Accordingly, an iterative off-grid turbo CE (IOTCE algorithm is proposed to renew and upgrade the CE between the integral grid part and the fractional off-grid part under the Turbo principle. By fully exploiting the sparse structure of mmWave channels, the integral grid part is estimated by a soft-decoding based compressed sensing (CS method called improved turbo compressed channel sensing (ITCCS. It iteratively updates the soft information between the linear minimum mean square error (LMMSE estimator and the sparsity combiner. Monte Carlo simulations are presented to evaluate the performance of the proposed method, and the results show that it enhances the angle

  18. An Off-Grid Turbo Channel Estimation Algorithm for Millimeter Wave Communications.

    Science.gov (United States)

    Han, Lingyi; Peng, Yuexing; Wang, Peng; Li, Yonghui

    2016-09-22

    The bandwidth shortage has motivated the exploration of the millimeter wave (mmWave) frequency spectrum for future communication networks. To compensate for the severe propagation attenuation in the mmWave band, massive antenna arrays can be adopted at both the transmitter and receiver to provide large array gains via directional beamforming. To achieve such array gains, channel estimation (CE) with high resolution and low latency is of great importance for mmWave communications. However, classic super-resolution subspace CE methods such as multiple signal classification (MUSIC) and estimation of signal parameters via rotation invariant technique (ESPRIT) cannot be applied here due to RF chain constraints. In this paper, an enhanced CE algorithm is developed for the off-grid problem when quantizing the angles of mmWave channel in the spatial domain where off-grid problem refers to the scenario that angles do not lie on the quantization grids with high probability, and it results in power leakage and severe reduction of the CE performance. A new model is first proposed to formulate the off-grid problem. The new model divides the continuously-distributed angle into a quantized discrete grid part, referred to as the integral grid angle, and an offset part, termed fractional off-grid angle. Accordingly, an iterative off-grid turbo CE (IOTCE) algorithm is proposed to renew and upgrade the CE between the integral grid part and the fractional off-grid part under the Turbo principle. By fully exploiting the sparse structure of mmWave channels, the integral grid part is estimated by a soft-decoding based compressed sensing (CS) method called improved turbo compressed channel sensing (ITCCS). It iteratively updates the soft information between the linear minimum mean square error (LMMSE) estimator and the sparsity combiner. Monte Carlo simulations are presented to evaluate the performance of the proposed method, and the results show that it enhances the angle detection

  19. Handbook of RF, microwave, and millimeter-wave components

    CERN Document Server

    Smolskiy, Sergey M; Kochemasov, Victor N

    2012-01-01

    This unique and comprehensive resource offers you a detailed treatment of the operations principles, key parameters, and specific characteristics of active and passive RF, microwave, and millimeter-wave components. The book covers both linear and nonlinear components that are used in a wide range of application areas, from communications and information sciences, to avionics, space, and military engineering. This practical book presents descriptions and clear examples and of the best materials and products used in the field, including laminates, prepregs, substrates; microstrip, coaxial and wa

  20. Millimeter Wave Radar for Atmospheric Turbulence Characterization and Wind Profiling for Improved Naval Operations

    Science.gov (United States)

    2016-12-29

    we consider the capabilities of a millimeter-wave radar to make atmospheric air flow measurements relevant to naval operations . The measurements could...Conclusions 14 References 14 1iii Millimeter Wave Radar for Atmospheric Turbulence Characterization and Wind Profiling for Improved Naval Operations Ben Rock... operations . We begin with a discussion of previous efforts to mitigate the aforementioned difficulties, and argue that millimeter wave radar techniques can be

  1. Quantum-limited detection of millimeter waves using superconducting tunnel junctions

    Energy Technology Data Exchange (ETDEWEB)

    Mears, C.A.

    1991-09-01

    The quasiparticle tunneling current in a superconductor-insulator- superconductor (SIS) tunnel junction is highly nonlinear. Such a nonlinearity can be used to mix two millimeter wave signals to produce a signal at a much lower intermediate frequency. We have constructed several millimeter and sub-millimeter wave SIS mixers in order to study high frequency response of the quasiparticle tunneling current and the physics of high frequency mixing. We have made the first measurement of the out-of-phase tunneling currents in an SIS tunnel junction. We have developed a method that allows us to determine the parameters of the high frequency embedding circuit by studying the details of the pumped I-V curve. We have constructed a 80--110 GHz waveguide-based mixer test apparatus that allows us to accurately measure the gain and added noise of the SIS mixer under test. Using extremely high quality tunnel junctions, we have measured an added mixer noise of 0.61 {plus minus} 0.36 quanta, which is within 25 percent of the quantum limit imposed by the Heisenberg uncertainty principle. This measured performance is in excellent agreement with that predicted by Tucker's theory of quantum mixing. We have also studied quasioptically coupled millimeter- and submillimeter-wave mixers using several types of integrated tuning elements. 83 refs.

  2. Quantum-limited detection of millimeter waves using superconducting tunnel junctions

    Energy Technology Data Exchange (ETDEWEB)

    Mears, Carl Atherton [Univ. of California, Berkeley, CA (United States)

    1991-09-01

    The quasiparticle tunneling current in a superconductor-insulator- superconductor (SIS) tunnel junction is highly nonlinear. Such a nonlinearity can be used to mix two millimeter wave signals to produce a signal at a much lower intermediate frequency. We have constructed several millimeter and sub-millimeter wave SIS mixers in order to study high frequency response of the quasiparticle tunneling current and the physics of high frequency mixing. We have made the first measurement of the out-of-phase tunneling currents in an SIS tunnel junction. We have developed a method that allows us to determine the parameters of the high frequency embedding circuit by studying the details of the pumped I-V curve. We have constructed a 80--110 GHz waveguide-based mixer test apparatus that allows us to accurately measure the gain and added noise of the SIS mixer under test. Using extremely high quality tunnel junctions, we have measured an added mixer noise of 0.61 ± 0.36 quanta, which is within 25 percent of the quantum limit imposed by the Heisenberg uncertainty principle. This measured performance is in excellent agreement with that predicted by Tucker`s theory of quantum mixing. We have also studied quasioptically coupled millimeter- and submillimeter-wave mixers using several types of integrated tuning elements. 83 refs.

  3. Millimeter Wave Spectroscopy in a Semi-Confocal Fabry-Perot Cavity

    Science.gov (United States)

    Drouin, Brian; Tang, Adrian; Reck, Theodore J.; Nemchick, Deacon J.; Cich, Matthew J.; Crawford, Timothy J.; Raymond, Alexander W.; Chang, M.-C. Frank; Kim, Rod M.

    2017-06-01

    A new generation of CMOS circuits operating at 89-104 GHz with improved output power and pulse switch isolation have enhanced the performance of the miniaturized pulsed-echo Fourier transform spectrometer under development for planetary exploration at the Jet Propulsion laboratory. Additional progress has been made by creating a waveguide-fed structure for the novel planar coupler design. This structure has enabled characterization of each component in the system and enabled spectroscopy to be done with conventional millimeter hardware that enables (1) direct comparisons to the CMOS components, (2) enhanced bandwidth of 74-109 GHz, and (3) amplification of the transmitter prior to cavity injection. We have now demonstrated the technique with room temperature detections on multiple species including N_2O, OCS, CH_3CN, CH_3OH, CH_3NH_2, CH_3CHO, CH_3Cl, HDO, D_2O, CH_3CH_2CN and CH_3CH_2OH. Of particular interest to spectroscopic work in the millimeter range is the ongoing incorporation of a ΔΣ radio-frequency source into the millimeter-wave lock-loop - this has improved the phase-noise of the tunable CMOS transceiver to better than the room-temperature Doppler limit and provides a promising source for general use that may replace the high end microwave synthesizers. We are in the process of building a functional interface to the various subsystems. We will present a trade-space study to determine the optimal operating conditions of the pulse-echo system.

  4. Characteristics of enhanced-mode AlGaN/GaN MIS HEMTs for millimeter wave applications

    Science.gov (United States)

    Lee, Jong-Min; Ahn, Ho-Kyun; Jung, Hyun-Wook; Shin, Min Jeong; Lim, Jong-Won

    2017-09-01

    In this paper, an enhanced-mode (E-mode) AlGaN/GaN high electron mobility transistor (HEMT) was developed by using 4-inch GaN HEMT process. We designed and fabricated Emode HEMTs and characterized device performance. To estimate the possibility of application for millimeter wave applications, we focused on the high frequency performance and power characteristics. To shift the threshold voltage of HEMTs we applied the Al2O3 insulator to the gate structure and adopted the gate recess technique. To increase the frequency performance the e-beam lithography technique was used to define the 0.15 um gate length. To evaluate the dc and high frequency performance, electrical characterization was performed. The threshold voltage was measured to be positive value by linear extrapolation from the transfer curve. The device leakage current is comparable to that of the depletion mode device. The current gain cut-off frequency and the maximum oscillation frequency of the E-mode device with a total gate width of 150 um were 55 GHz and 168 GHz, respectively. To confirm the power performance for mm-wave applications the load-pull test was performed. The measured power density of 2.32 W/mm was achieved at frequencies of 28 and 30 GHz.

  5. Compressive Sensing for Millimeter Wave Antenna Array Diagnosis

    KAUST Repository

    Eltayeb, Mohammed E.

    2016-12-19

    The radiation pattern of an antenna array depends on the excitation weights and the geometry of the array. Due to wind and atmospheric conditions, outdoor millimeter wave antenna elements are subject to full or partial blockages from a plethora of particles like dirt, salt, ice, and water droplets. Handheld devices are also subject to blockages from random finger placement and/or finger prints. These blockages cause absorption and scattering to the signal incident on the array, and change the array geometry. This distorts the far-field radiation pattern of the array leading to an increase in the sidelobe level and decrease in gain. This paper studies the effects of blockages on the far-field radiation pattern of linear arrays and proposes two array diagnosis techniques for millimeter wave antenna arrays. The proposed techniques jointly estimate the locations of the blocked antennas and the induced attenuation and phase shifts. Numerical results show that the proposed techniques provide satisfactory results in terms of fault detection with reduced number of measurements (diagnosis time) provided that the number of blockages is small compared to the array size.

  6. Microwave and Millimeter Wave Imaging Using Synthetic Aperture Focusing and Holographical Techniques

    Science.gov (United States)

    Case, Joseph Tobias

    2005-01-01

    Microwave and millimeter wave nondestructive testing and evaluation (NDT&E) methods have shown great potential for determining material composition in composite structures, determining material thickness or debond thickness between two layers, and determining the location and size of flaws, defects, and anomalies. The same testing methods have also shown great potential to produce relatively high-resolution images of voids inside Spray On Foam Insulation (SOFI) test panels using real focused methods employing lens antennas. An alternative to real focusing methods are synthetic focusing methods. The essence of synthetic focusing is to match the phase of the scattered signal to measured points spaced regularly on a plane. Many variations of synthetic focusing methods have already been developed for radars, ultrasonic testing applications, and microwave concealed weapon detection. Two synthetic focusing methods were investigated; namely, a) frequency-domain synthetic aperture focusing technique (FDSAFT), and b) wide-band microwave holography. These methods were applied towards materials whose defects were of low dielectric contrast like air void in SOFI. It is important to note that this investigation used relatively low frequencies from 8.2 GHz to 26.5 GHz that are not conducive for direct imaging of the SOFI. The ultimate goal of this work has been to demonstrate the capability of these methods before they are applied to much higher frequencies such as the millimeter wave frequency spectrum (e.g., 30-300 GHz).

  7. Study of transmission line attenuation in broad band millimeter wave frequency range

    Energy Technology Data Exchange (ETDEWEB)

    Pandya, Hitesh Kumar B. [ITER-India, IPR, Gandhinagar, Gujarat (India); Austin, M. E. [Institute for Fusion Studies, the University of Texas at Austin, Austin, Texas (United States); Ellis, R. F. [Laboratory for Plasma and Fusion Energy Studies, University of Maryland, College Park, Maryland 20742 (United States)

    2013-10-15

    Broad band millimeter wave transmission lines are used in fusion plasma diagnostics such as electron cyclotron emission (ECE), electron cyclotron absorption, reflectometry and interferometry systems. In particular, the ECE diagnostic for ITER will require efficient transmission over an ultra wide band, 100 to 1000 GHz. A circular corrugated waveguide transmission line is a prospective candidate to transmit such wide band with low attenuation. To evaluate this system, experiments of transmission line attenuation were performed and compared with theoretical loss calculations. A millimeter wave Michelson interferometer and a liquid nitrogen black body source are used to perform all the experiments. Atmospheric water vapor lines and continuum absorption within this band are reported. Ohmic attenuation in corrugated waveguide is very low; however, there is Bragg scattering and higher order mode conversion that can cause significant attenuation in this transmission line. The attenuation due to miter bends, gaps, joints, and curvature are estimated. The measured attenuation of 15 m length with seven miter bends and eighteen joints is 1 dB at low frequency (300 GHz) and 10 dB at high frequency (900 GHz), respectively.

  8. Study of transmission line attenuation in broad band millimeter wave frequency range.

    Science.gov (United States)

    Pandya, Hitesh Kumar B; Austin, M E; Ellis, R F

    2013-10-01

    Broad band millimeter wave transmission lines are used in fusion plasma diagnostics such as electron cyclotron emission (ECE), electron cyclotron absorption, reflectometry and interferometry systems. In particular, the ECE diagnostic for ITER will require efficient transmission over an ultra wide band, 100 to 1000 GHz. A circular corrugated waveguide transmission line is a prospective candidate to transmit such wide band with low attenuation. To evaluate this system, experiments of transmission line attenuation were performed and compared with theoretical loss calculations. A millimeter wave Michelson interferometer and a liquid nitrogen black body source are used to perform all the experiments. Atmospheric water vapor lines and continuum absorption within this band are reported. Ohmic attenuation in corrugated waveguide is very low; however, there is Bragg scattering and higher order mode conversion that can cause significant attenuation in this transmission line. The attenuation due to miter bends, gaps, joints, and curvature are estimated. The measured attenuation of 15 m length with seven miter bends and eighteen joints is 1 dB at low frequency (300 GHz) and 10 dB at high frequency (900 GHz), respectively.

  9. Precipitating Snow Retrievals from Combined Airborne Cloud Radar and Millimeter-Wave Radiometer Observations

    Science.gov (United States)

    Grecu, Mircea; Olson, William S.

    2008-01-01

    An algorithm for retrieving snow over oceans from combined cloud radar and millimeter-wave radiometer observations is developed. The algorithm involves the use of physical models to simulate cloud radar and millimeter-wave radiometer observations from basic atmospheric variables such as hydrometeor content, temperature, and relative humidity profiles and is based on an optimal estimation technique to retrieve these variables from actual observations. A high-resolution simulation of a lake-effect snowstorm by a cloud-resolving model is used to test the algorithm. That is, synthetic observations are generated from the output of the cloud numerical model, and the retrieval algorithm is applied to the synthetic data. The algorithm performance is assessed by comparing the retrievals with the reference variables used in synthesizing the observations. The synthetic observation experiment indicates good performance of the retrieval algorithm. The algorithm is also applied to real observations from the Wakasa Bay field experiment that took place over the Sea of Japan in January and February 2003. The application of the retrieval algorithm to data from the field experiment yields snow estimates that are consistent with both the cloud radar and radiometer observations.

  10. Towards 5G: A Photonic Based Millimeter Wave Signal Generation for Applying in 5G Access Fronthaul.

    Science.gov (United States)

    Alavi, S E; Soltanian, M R K; Amiri, I S; Khalily, M; Supa'at, A S M; Ahmad, H

    2016-01-27

    5G communications require a multi Gb/s data transmission in its small cells. For this purpose millimeter wave (mm-wave) RF signals are the best solutions to be utilized for high speed data transmission. Generation of these high frequency RF signals is challenging in electrical domain therefore photonic generation of these signals is more studied. In this work, a photonic based simple and robust method for generating millimeter waves applicable in 5G access fronthaul is presented. Besides generating of the mm-wave signal in the 60 GHz frequency band the radio over fiber (RoF) system for transmission of orthogonal frequency division multiplexing (OFDM) with 5 GHz bandwidth is presented. For the purpose of wireless transmission for 5G application the required antenna is designed and developed. The total system performance in one small cell was studied and the error vector magnitude (EVM) of the system was evaluated.

  11. Module integration and amplifier design optimization for optically enabled passive millimeter-wave imaging

    Science.gov (United States)

    Wright, Andrew A.; Martin, Richard D.; Schuetz, Christopher A.; Shi, Shouyuan; Zhang, Yifei; Yao, Peng; Shreve, Kevin P.; Dillon, Thomas E.; Mackrides, Daniel G.; Harrity, Charles E.; Prather, Dennis W.

    2016-05-01

    This paper will discuss the development of a millimeter-wave (mm-wave) receiver module used in a sparse array passive imaging system. Using liquid crystal polymer (LCP) technology and low power InP low noise amplifiers (LNA), enables the integration of the digital circuitry along with the RF components onto a single substrate significantly improves the size, weight, power, and cost (SWaP-C) of the mm-wave receiver module compared to previous iterations of the module. Also comparing with previous generation modules, the operating frequency has been pushed from 77 GHz to 95 GHz in order to improve the resolution of the captured image from the sparse array imaging system.

  12. Spatial Stationarity of Ultrawideband and Millimeter Wave Radio Channels

    DEFF Research Database (Denmark)

    Yi, Tan; Nielsen, Jesper Ødum; Pedersen, Gert F.

    2016-01-01

    For radio channels with broad bandwidth resource, such as those often used for ultrawideband (UWB) and millimeter wave (mmwave) systems, the Wide-Sense Stationary Uncorrelated Scattering (WSSUS) and spatial stationary assumptions are more critical than typical cellular channels with very limited...... bandwidth resource. This paper studies spatial stationarity and bandwidth dependency of the Multipath Component (MPC) parameters, and the concept of local region of stationarity (LRS) is used as the measure of the physical stationarity region. LRS calculation results based on channel measurements show...... that the size of LRS is bandwidth dependent in all measured bands, 2–4 GHz, 14–16 GHz, and 28–30 GHz. The results in this paper point out that an inappropriate choice of bandwidth in channel parameter estimation could violate spatial stationary assumptions. The paper indicates LRS sizes for different bandwidths...

  13. Laboratory millimeter wave spectrum of N-methylhydroxylamine

    Science.gov (United States)

    Kolesniková, L.; Alonso, E. R.; Mata, S.; Alonso, J. L.

    2017-05-01

    The pure rotational spectrum of N-methylhydroxylamine (CH3NHOH), a potential candidate in the interstellar medium, has been studied in the millimeter-wave region up to 360 GHz. The molecule was liberated from its hydrochloride salt and the ground and six lowest excited vibrational states of the most stable trans conformation as well as the 13C isotopologue in natural abundance have been measured and analyzed. From the observed ground state A-E splittings, a barrier hindering the methyl internal rotation V3 = 1245.8 (46) cm-1 has been derived. The sub-Doppler Lamb-dip technique has been employed to resolve the 14N hyperfine structure of strong transitions. The spectroscopic constants reported in the present study should constitute a solid set of laboratory data to support future searches of N-methylhydroxylamine in the interstellar medium.

  14. Permittivity of water at millimeter wave-lengths

    Science.gov (United States)

    Blue, M. D.

    1976-01-01

    Work performed on the permittivity of seawater and ice at 100 GHz was described. Measurements on water covered the temperature range from 0 to 50 C, while the measurements on ice were taken near - 10 C. In addition, a small number of measurements were made on the reflectivity of absorber materials used in a previous program on research in millimeter wave techniques. Normal incidence reflectivity was measured, and the result was used to obtain the index of refraction. For the case of normal incidence, reflectivity at a fixed temperature was reproducible to 1% for values near 40%. For reflectivity measurements on ice, the lack of attenuation leads to reflection from the back surface of the sample; this complication was circumvented by using a wedge shaped sample and freezing the water in a container lined with absorber material.

  15. Simulating the operation of millimeter-wave imaging systems

    Science.gov (United States)

    Appleby, Roger; Ferguson, Stuart

    2012-10-01

    This paper describes how an open source 3D computer modeling, animation and visualization software package was modified to simulate the millimeter-wave imaging process. The data that describes the scene is specified with a network of interconnected planar triangular polygons. Each polygon is assigned a material type that defines a number of attributes such as thickness, and temperature, the material can also define the optical properties using refractive index or reflectivity, transmission and emissivity. The Bidirectional Reflectance Distribution Function (BRDF) can also be used for reflection from rough surfaces. The scene, which may contain human figures can be animated to show movement. The paper describes the key elements of the radiometric model and how a post processing technique allows a range of different types of imagers to be simulated with noise and depth of field. The paper concludes with some examples and a discussion of how accurate such a modeling approach can be.

  16. Integrated Coherent Radio-over-Fiber Units for Millimeter-Wave Wireless Access

    DEFF Research Database (Denmark)

    Stöhr, A.; Babiel, S.; Chuenchom, M.

    2015-01-01

    to provide wireless services within the E-band (60-90 GHz). In detail, GaAs-based single-sideband millimeter-wave Mach-Zehnder modulators, InP-based millimeter-wave photodiodes featuring rectangular waveguide outputs and monolithically integrated low-linewidth tunable laser diodes as well as Si......Ge-based millimeter-wave RF amplifier technology will be reported. In addition, a new coherent optical heterodyne radio-over–fiber scheme is proposed for seamless integration of next generation millimeter-wave wireless access systems into a next generation passive optical network employing dense or even ultra......-dense WDM. We propose and demonstrate novel radio access units (RAU) using coherent optical heterodyne detection for the generation of the millimeter-wave radio signals in the RAUs. The proposed CRoF concept supports the provision of multiple services over a single optical distribution network including...

  17. On the performance of millimeter wave-based RF-FSO links with HARQ feedback

    KAUST Repository

    Makki, Behrooz

    2016-12-24

    This paper studies the performance of hybrid radio-frequency (RF) and free-space optical (FSO) links in the cases with and without hybrid automatic repeat request (HARQ). Considering millimeter wave (mmwave) characteristics in the RF link and pointing errors in the FSO link, we derive closed-form expressions for the message decoding probabilities as well as the throughput and the outage probability of the RF-FSO setups. We also evaluate the effect of various parameters such as power amplifiers efficiency, different transmission techniques in the FSO link, pointing errors in the FSO link as well as different coherence times/symbol rates of the RF and the FSO links on the throughput and outage probability. The results show the efficiency of the RF-FSO links in different conditions. Moreover, the HARQ can effectively improve the outage probability/energy efficiency, and compensate the effect of hardware impairments in RF-FSO links.

  18. A Millimeter Wave Spectrophotometry by a Wide Band Oscillator of the Ledatron

    Science.gov (United States)

    Suto, Shozo; Ikezawa, Mikihiko

    1983-04-01

    For the purpose of the wavelength scanning spectroscopy in the millimeter wave region, we have made a wide band oscillator using the Ledatron tube. The pulsed output signal is obtained in the wavelength range from 2.6 to 9 mm (1.1 to 3.9 cm-1) almost continuously. The peak output power is over several hundred milliwatts from 4 to 9 mm and over several tens of milliwatts from 2.6 to 4 mm. With this source, a spectrophotometer has been constructed in which light pipes are used as wave guides and the fluctuation of the signal is averaged by a boxcar integrator. A measurement of absorption spectra is demonstrated for a solid state sample of NaCl:OH-.

  19. Phase and Amplitude Drift Research of Millimeter Wave Band Local Oscillator System

    Directory of Open Access Journals (Sweden)

    Changhoon Lee

    2010-06-01

    Full Text Available In this paper, we developed a local oscillator (LO system of millimeter wave band receiver for radio astronomy observation. We measured the phase and amplitude drift stability of this LO system. The voltage control oscillator (VCO of this LO system use the 3 mm band Gunn oscillator. We developed the digital phase locked loop (DPLL module for the LO PLL function that can be computer-controlled. To verify the performance, we measured the output frequency/power and the phase/amplitude drift stability of the developed module and the commercial PLL module, respectively. We show the good performance of the LO system based on the developed PLL module from the measured data analysis. The test results and discussion will be useful tutorial reference to design the LO system for very long baseline interferometry (VLBI receiver and single dish radio astronomy receiver at the 3 mm frequency band.

  20. Multimode fibers in millimeter-wave evolution for 5G cellular networks

    Science.gov (United States)

    Vázquez, C.; Montero, D. S.; Ponce, W.; Lallana, P. C.; Larrabeiti, D.; Montalvo, J.; Tapetado, A.; Pinzón, P. J.

    2016-02-01

    Small-cell and cloud-RAN systems along with the use of the millimeter-wave band have been considered as promising solutions to meet the capacity demand of the future wireless access networks. Radio over Multimode fibers (RoMMF) can play a role in the integrated optical-wireless access systems for next-generation wireless communications, mainly in within-building environments. The numerical results show the effectiveness of MMF to transmit at 60 GHz band with 7- GHz bandwidth for different link lengths and refractive index profiles under restricted mode launching and using narrow linewidth sources. The integration with optically powered remote antenna units is also proposed based on the large core effective area of MMF. Temperature impairments and graded index plastic optical fiber transmission are also discussed.

  1. Effects of Millimeter-Wave Electromagnetic Radiation on the Experimental Model of Migraine.

    Science.gov (United States)

    Sivachenko, I B; Medvedev, D S; Molodtsova, I D; Panteleev, S S; Sokolov, A Yu; Lyubashina, O A

    2016-02-01

    Effects of millimeter-wave electromagnetic radiation (40 GHz frequency, 0.01 mW power) on the spontaneous fi ring of convergent neurons of the spinal trigeminal nucleus and their responses to electrical stimulation of the dura mater were studied in neurophysiological experiments on rats. Irradiation of the area of cutaneous receptive fields of spinal trigeminal nucleus reversibly inhibited both spontaneous discharges and activity induced by electrical stimulation of the dura mater. The second and third exposures to electromagnetic radiation with an interval of 10 min were ineffective. These results suggest that suppression of neuronal excitability in the spinal trigeminal ganglion can be a mechanism of the anti-migraine effects of electromagnetic radiation observed in clinical practice.

  2. Chaotic millimeter wave generation in a helical-waveguide gyro-TWT with delayed feedback

    Science.gov (United States)

    Ginzburg, N. S.; Rozental, R. M.; Sergeev, A. S.; Zotova, I. V.; Tarakanov, V. P.

    2016-10-01

    We demonstrate the possibility of chaotic millimeter wave generation in broadband helical-waveguide gyrotron travelling wave tubes (gyro-TWTs) by introducing external delayed feedback. It is shown that for the realization of "developed" chaos the amplitude characteristic of the amplifier should have the maximum slope in the overdrive regime upon saturation. This can be achieved by proper choosing of cyclotron resonance detuning. According to the time-domain averaged model and 3D particle-in-cell simulations with the parameters of the experimentally realized 35 GHz gyro-TWT, the power of chaotic generation can achieve 50 kW for an electron mean efficiency of about 7% and a spectrum width of 3-4 GHz.

  3. Ultra-Wideband Phased Array for Millimeter-Wave 5G and ISM

    Science.gov (United States)

    Novak, Markus H.; Volakis, John L.; Miranda, Felix A.

    2016-01-01

    Growing mobile data consumption has prompted the exploration of the millimeter-wave spectrum for large bandwidth, high speed communications. However, the allocated bands are spread across a wide swath of spectrum: fifth generation mobile architecture (5G): 28, 38, 39, 64-71 GHz, as well as Industrial, Scientific, and Medical bands (ISM): 24 and 60 GHz. Moreover, high gain phased arrays are required to overcome the significant path loss associated with these frequencies. Further, it is necessary to incorporate several of these applications in a single, small size and low cost platform. To this end, we have developed a scanning, Ultra-Wideband (UWB) array which covers all 5G, ISM, and other mm-W bands from 24-72 GHz. Critically, this is accomplished using mass-production Printed Circuit Board (PCB) fabrication.

  4. Ultra-Wideband Array in PCB for Millimeter-Wave 5G and ISM

    Science.gov (United States)

    Novak, Markus H.; Volakis, John L.; Miranda, Felix A.

    2017-01-01

    Growing mobile data consumption has prompted the exploration of the millimeter-wave spectrum for large bandwidth, high speed communications. However, the allocated bands are spread across a wide swath of spectrum: Fifth generation mobile architecture (5G): 28, 38, 39, 6471 GHz; Industrial, Scientific, and Medical bands (ISM): 24, 60 GHz. Moreover, high gain phased arrays are required to overcome the significant path loss associated with these frequencies. Further, it is necessary to incorporate several of these applications in a single, small size and low cost platform. To this end, we have developed a scanning, Ultra-Wideband (UWB) array which covers all 5G, ISM, and other mm-W bands from 2472 GHz. Critically, this is accomplished using mass-production Printed Circuit Board (PCB) fabrication. The results of this work are presented in this poster.

  5. Image fusion based on millimeter-wave for concealed weapon detection

    Science.gov (United States)

    Zhu, Weiwen; Zhao, Yuejin; Deng, Chao; Zhang, Cunlin; Zhang, Yalin; Zhang, Jingshui

    2010-11-01

    This paper describes a novel multi sensors image fusion technology which is presented for concealed weapon detection (CWD). It is known to all, because of the good transparency of the clothes at millimeter wave band, a millimeter wave radiometer can be used to image and distinguish concealed contraband beneath clothes, for example guns, knives, detonator and so on. As a result, we adopt the passive millimeter wave (PMMW) imaging technology for airport security. However, in consideration of the wavelength of millimeter wave and the single channel mechanical scanning, the millimeter wave image has law optical resolution, which can't meet the need of practical application. Therefore, visible image (VI), which has higher resolution, is proposed for the image fusion with the millimeter wave image to enhance the readability. Before the image fusion, a novel image pre-processing which specifics to the fusion of millimeter wave imaging and visible image is adopted. And in the process of image fusion, multi resolution analysis (MRA) based on Wavelet Transform (WT) is adopted. In this way, the experiment result shows that this method has advantages in concealed weapon detection and has practical significance.

  6. Palm-shaped spectrum generation for dual-band millimeter wave and baseband signals over fiber

    Science.gov (United States)

    Lin, R.; Feng, Z.; Tang, M.; Wang, R.; Fu, S.; Shum, P.; Liu, D.; Chen, J.

    2016-05-01

    In order to offer abundant available bandwidth for radio access networks satisfying future 5G requirements on capacity, this paper proposes a simple and cost-effective palm-shaped spectrum generation scheme that can be used for high capacity radio over fiber (RoF) system. The proposed scheme can simultaneously generate an optical carrier used for upstream and two bands of millimeter wave (MMW) that are capable of carrying different downstream data. The experiment results show that the proposed palm-shaped spectrum generation scheme outperforms optical frequency comb (OFC) based multi-band MMW generation in terms of upstream transmission performance. Furthermore, simulation is carried out with different dual-band MMW configurations to verify the feasibility of using the proposed spectrum generation scheme in the RoF system.

  7. Indoor Operations by FMCW Millimeter Wave SAR Onboard Small UAS: A Simulation Approach

    Directory of Open Access Journals (Sweden)

    Antonio Fulvio Scannapieco

    2016-01-01

    Full Text Available A dedicated system simulator is presented in this paper for indoor operations onboard small Unmanned Aerial Systems (UAS by a novel millimeter wave radar sensor. The sensor relies on the principle of Synthetic Aperture Radar (SAR applied to a Frequency Modulated Continuous Wave (FMCW radar system. Input to the simulator are both design parameters for Synthetic Aperture Radar (SAR, which should be able to cope with the stringent requirements set by indoor operations, and information about platform navigation and observed scene. The scene generation task is described in detail. This is based on models for point target response on either a completely absorbing background or fluctuating background and ray tracing (RT techniques. Results obtained from scene processing are finally discussed, giving further insights on expected results from high-resolution observation of an assigned control volume by this novel SAR sensor.

  8. Review of 3D Printed Millimeter-Wave and Terahertz Passive Devices

    Directory of Open Access Journals (Sweden)

    Bing Zhang

    2017-01-01

    Full Text Available The 3D printing technology is catching attention nowadays. It has certain advantages over the traditional fabrication processes. We give a chronical review of the 3D printing technology from the time it was invented. This technology has also been used to fabricate millimeter-wave (mmWave and terahertz (THz passive devices. Though promising results have been demonstrated, the challenge lies in the fabrication tolerance improvement such as dimensional tolerance and surface roughness. We propose the design methodology of high order device to circumvent the dimensional tolerance and suggest specific modelling of the surface roughness of 3D printed devices. It is believed that, with the improvement of the 3D printing technology and related subjects in material science and mechanical engineering, the 3D printing technology will become mainstream for mmWave and THz passive device fabrication.

  9. Random-Access Technique for Self-Organization of 5G Millimeter-Wave Cellular Communications

    Directory of Open Access Journals (Sweden)

    Jasper Meynard Arana

    2016-01-01

    Full Text Available The random-access (RA technique is a key procedure in cellular networks and self-organizing networks (SONs, but the overall processing time of this technique in millimeter-wave (mm-wave cellular systems with directional beams is very long because RA preambles (RAPs should be transmitted in all directions of Tx and Rx beams. In this paper, two different types of preambles (RAP-1 and RAP-2 are proposed to reduce the processing time in the RA stage. After analyzing the correlation property, false-alarm probability, and detection probability of the proposed RAPs, we perform simulations to show that the RAP-2 is suitable for RA in mm-wave cellular systems with directional beams because of the smaller processing time and high detection probability in multiuser environments.

  10. Millimeter-wave and Terahertz Reconfigurable Radio-over-Fiber Systems

    DEFF Research Database (Denmark)

    Vegas Olmos, Juan José

    on photonic technologies enable to generate, transport and radiate in a straight forward manner microwave and millimeter wave signals. Although electronic technologies are able to sustain an increase in frequency from a technology point of view, with current developments hitting the Terahertz regime...... when deploying fiber is not an option. Radio-over-Fiber (RoF) technologies have evolved from a blue sky academic topic in the 90s to a main driver within the current quest for the 5th generation mobile systems (5G). A twist in RoF technologies is that it has found along the way niches in areas non...... purely related to communication technologies (ICT) applications: distribution of highly pure clock signals for radio telescopes, photonic-based coherent radar and fiber optic sensing. It is however in the communication arena where RoF seems to be able to provide a technological edge; RoF techniques based...

  11. Optical and millimeter-wave radio seamless MIMO transmission based on a radio over fiber technology.

    Science.gov (United States)

    Kanno, Atsushi; Kuri, Toshiaki; Hosako, Iwao; Kawanishi, Tetsuya; Yoshida, Yuki; Yasumura, Yoshihiro; Kitayama, Ken-ichi

    2012-12-31

    Multi-input multi-output (MIMO) transmission of two millimeter-wave radio signals seamlessly converted from polarization-division-multiplexed quadrature-phase-shift-keying optical signals is successfully demonstrated, where a radio access unit basically consisting of only optical-to-electrical converters and a radio receiver performs total signal equalization of both the optical and the radio paths and demodulation with digital signal processing (DSP). Orthogonally polarized optical components that are directly converted to two-channel radio components can be demultiplexed and demodulated with high-speed DSP as in optical digital coherent detection. 20-Gbaud optical and radio seamless MIMO transmission provides a total capacity of 74.4 Gb/s with a forward error correction overhead of 7%.

  12. On the Security of Millimeter Wave Vehicular Communication Systems Using Random Antenna Subsets

    KAUST Repository

    Eltayeb, Mohammed E.

    2017-03-20

    Millimeter wave (mmWave) vehicular communication systems have the potential to improve traffic efficiency and safety. Lack of secure communication links, however, may lead to a formidable set of abuses and attacks. To secure communication links, a physical layer precoding technique for mmWave vehicular communication systems is proposed in this paper. The proposed technique exploits the large dimensional antenna arrays available at mmWave systems to produce direction dependent transmission. This results in coherent transmission to the legitimate receiver and artificial noise that jams eavesdroppers with sensitive receivers. Theoretical and numerical results demonstrate the validity and effectiveness of the proposed technique and show that the proposed technique provides high secrecy throughput when compared to conventional array and switched array transmission techniques.

  13. Multispectral illumination and image processing techniques for active millimeter-wave concealed object detection.

    Science.gov (United States)

    Zhang, Lixiao; Stiens, Johan; Elhawil, Amna; Vounckx, Roger

    2008-12-01

    Active millimeter-wave imaging systems for concealed object detection offer the possibility of much higher image contrast than passive systems, especially in indoor applications. By studying active millimeter-wave images of different test objects derived in the W band, we show that multispectral illumination is critical to the detectability of targets. We also propose to use image change detection techniques, including image differencing, normalized difference vegetation index, and principle component analysis to process the multispectral millimeter-wave images. The results demonstrate that multispectral illumination can significantly reveal the object features hidden by image artifacts and improve the appearance of the objects.

  14. Infrared and millimeter waves v.15 millimeter components and techniques, pt.VI

    CERN Document Server

    Button, Kenneth J

    1986-01-01

    Infrared and Millimeter Waves, Volume 15: Millimeter Components and Techniques, Part VI is concerned with millimeter-wave guided propagation and integrated circuits. This book covers low-noise receiver technology for near-millimeter wavelengths; dielectric image-line antennas; EHF satellite communications (SATCOM) terminal antennas; and semiconductor antennas for millimeter-wave integrated circuits. A scanning airborne radiometer for 30 and 90 GHz and a self-oscillating mixer are also described. This monograph is comprised of six chapters and begins with a discussion on the design of low-n

  15. High power switching and other high power devices

    Science.gov (United States)

    Gundersen, Martin

    1992-09-01

    High power thyratrons and devices such as high power microwave sources have cathode-related performance limits. Research is described of a simple, robust 'super-emissive' cathode that produces greater than 10,000 A/sq cm from a macroscopic area (approx. 1 sq cm), and operates with a low pressure (approx. 0.1 torr), spatially uniform glow plasma (density greater than 1015 cu cm). The cathode also can operate as a hollow cathode, and is at the heart of the operation of the pseudospark and back-lighted thyratron. The physics of this hollow and super-emissive cathode is very rich. The hollow cathode geometry traps electrons in the hollow cathode backspace. The lifetime of these electrons enables them to ionize a spatially homogeneous high density glow, and this hollow cathode mode of operation is responsible for certain types of electron and ion beam behavior. A plasma cathode sheath that is formed during this phase leads to super-emissive behavior, which is responsible for high current emission. Super-emissive cathode thyratron-type switches (with higher peak current, voltage, di/dt) being developed for pulsed power switching of lasers, accelerators, high current and high coulomb transfer, Marx bank operation, transfer of technology to commercial applications, high current electron beams, and millimeter wave generation (1 to 100 GHz) are described.

  16. Improved-resolution millimeter-wave imaging through structured illumination.

    Science.gov (United States)

    Shayei, Ali; Kavehvash, Zahra; Shabany, Mahdi

    2017-05-20

    A resolution-improved active millimeter-wave (MMW) imaging structure, based on the theory of structured illumination, is proposed in this paper. The structured illumination is a well-defined concept for surpassing the diffraction limit in optical microscopy, where imposing grating patterns on the targeted object could help in moving the object frequency spectrum along the desired direction in the spatial frequency domain. This frequency shift helps in passing different parts of the object's frequency spectrum through the diffraction filter. The combination of resultant images provides a framework to pass a wider frequency band of the object, thereby achieving super-resolution. This idea has not yet been employed for MMW image resolution improvement due to practical limitations in producing the desired grating patterns. Therefore, a desired fringe pattern is produced here and tailored for a MMW imaging system through antenna array synthesis. In the proposed scheme, the structured illumination has been implemented for improving the MMW image resolution. Furthermore, an adaptive approach has been proposed in order to generalize the structure for resolution improvement in all required directions in a very fast manner. Electromagnetic simulation results show at most twofold improvement in the image resolution through the proposed MMW imaging structure.

  17. Passive millimeter-wave video camera for aviation applications

    Science.gov (United States)

    Fornaca, Steven W.; Shoucri, Merit; Yujiri, Larry

    1998-07-01

    Passive Millimeter Wave (PMMW) imaging technology offers significant safety benefits to world aviation. Made possible by recent technological breakthroughs, PMMW imaging sensors provide visual-like images of objects under low visibility conditions (e.g., fog, clouds, snow, sandstorms, and smoke) which blind visual and infrared sensors. TRW has developed an advanced, demonstrator version of a PMMW imaging camera that, when front-mounted on an aircraft, gives images of the forward scene at a rate and quality sufficient to enhance aircrew vision and situational awareness under low visibility conditions. Potential aviation uses for a PMMW camera are numerous and include: (1) Enhanced vision for autonomous take- off, landing, and surface operations in Category III weather on Category I and non-precision runways; (2) Enhanced situational awareness during initial and final approach, including Controlled Flight Into Terrain (CFIT) mitigation; (3) Ground traffic control in low visibility; (4) Enhanced airport security. TRW leads a consortium which began flight tests with the demonstration PMMW camera in September 1997. Flight testing will continue in 1998. We discuss the characteristics of PMMW images, the current state of the technology, the integration of the camera with other flight avionics to form an enhanced vision system, and other aviation applications.

  18. Millimeter-wave imaging diagnostics systems on the EAST tokamak (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Y. L.; Xie, J. L., E-mail: jlxie@ustc.edu.cn; Yu, C. X.; Zhao, Z. L.; Gao, B. X.; Chen, D. X.; Liu, W. D.; Liao, W.; Qu, C. M.; Luo, C. [School of Physics, University of Science and Technology of China, Anhui 230026 (China); Hu, X.; Spear, A. G.; Luhmann, N. C.; Domier, C. W.; Chen, M.; Ren, X. [University of California, Davis, California 95616 (United States); Tobias, B. J. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2016-11-15

    Millimeter-wave imaging diagnostics, with large poloidal span and wide radial range, have been developed on the EAST tokamak for visualization of 2D electron temperature and density fluctuations. A 384 channel (24 poloidal × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system in F-band (90-140 GHz) was installed on the EAST tokamak in 2012 to provide 2D electron temperature fluctuation images with high spatial and temporal resolution. A co-located Microwave Imaging Reflectometry (MIR) will be installed for imaging of density fluctuations by December 2016. This “4th generation” MIR system has eight independent frequency illumination beams in W-band (75-110 GHz) driven by fast tuning synthesizers and active multipliers. Both of these advanced millimeter-wave imaging diagnostic systems have applied the latest techniques. A novel design philosophy “general optics structure” has been employed for the design of the ECEI and MIR receiver optics with large aperture. The extended radial and poloidal coverage of ECEI on EAST is made possible by innovations in the design of front-end optics. The front-end optical structures of the two imaging diagnostics, ECEI and MIR, have been integrated into a compact system, including the ECEI receiver and MIR transmitter and receiver. Two imaging systems share the same mid-plane port for simultaneous, co-located 2D fluctuation measurements of electron density and temperature. An intelligent remote-control is utilized in the MIR electronics systems to maintain focusing at the desired radial region even with density variations by remotely tuning the probe frequencies in about 200 μs. A similar intelligent technique has also been applied on the ECEI IF system, with remote configuration of the attenuations for each channel.

  19. Miniaturized MMIC-Based Millimeter-Wave Frequency Synthesizers for Space Applications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — MMIC technology provides the technology base to reduce the size and weight of microwave and millimeter wave (MMW) equipment on board airborne and space-based...

  20. GPM GROUND VALIDATION CONICAL SCANNING MILLIMETER-WAVE IMAGING RADIOMETER (COSMIR) GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) dataset for the GPM Cold-season Precipitation Experiment (GCPEx) plays the role as an airborne...

  1. GPM GROUND VALIDATION CONICAL SCANNING MILLIMETER-WAVE IMAGING RADIOMETER (COSMIR) MC3E V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) dataset for the Midlatitude Continental Convective Clouds Experiment (MC3E) plays the role as an...

  2. GPM GROUND VALIDATION CONICAL SCANNING MILLIMETER-WAVE IMAGING RADIOMETER (COSMIR) IPHEx V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) IPHEx dataset includes data gathered during the Integrated Precipitation and...

  3. Seamless Optical Fiber-Wireless Millimeter- Wave Transmission Link for Access Networks

    DEFF Research Database (Denmark)

    Pang, Xiaodan; Lebedev, Alexander; Vegas Olmos, Juan José

    2013-01-01

    This paper presents an experimental demonstration of a millimeter-wave wireless bridge in the W-band for transparent broadband fiber access in the sub-urban areas, where full fiber connections are impracticable....

  4. A Temporal Millimeter Wave Propagation Model for Tunnels Using Ray Frustum Techniques and FFT

    Directory of Open Access Journals (Sweden)

    Choonghyen Kwon

    2014-01-01

    Full Text Available A temporal millimeter wave propagation model for tunnels is presented using ray frustum techniques and fast Fourier transform (FFT. To directly estimate or simulate effects of millimeter wave channel properties on the performance of communication services, time domain impulse responses of demodulated signals should be obtained, which needs rather large computation time. To mitigate the computational burden, ray frustum techniques are used to obtain frequency domain transfer function of millimeter wave propagation environment and FFT of equivalent low pass signals are used to retrieve demodulated waveforms. This approach is numerically efficient and helps to directly estimate impact of tunnel structures and surfaces roughness on the performance of millimeter wave communication services.

  5. GPM Ground Validation Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) OLYMPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) OLYMPEX dataset consists of brightness temperatures from 9 channels as...

  6. 60-GHz Millimeter-wave Over Fiber with Directly Modulated Dual-mode Laser Diode

    Science.gov (United States)

    Tsai, Cheng-Ting; Lin, Chi-Hsiang; Lin, Chun-Ting; Chi, Yu-Chieh; Lin, Gong-Ru

    2016-06-01

    A directly modulated dual-mode laser diode (DMLD) with third-order intermodulation distortion (IMD3) suppression is proposed for a 60-GHz millimeter-wave over fiber (MMWoF) architecture, enabling new fiber-wireless communication access to cover 4-km single-mode-fiber (SMF) and 3-m wireless 16-QAM OFDM transmissions. By dual-mode injection-locking, the throughput degradation of the DMLD is mitigated with saturation effect to reduce its threshold, IMD3 power and relative intensity noise to 7.7 mA, -85 dBm and -110.4 dBc/Hz, respectively, providing huge spurious-free dynamic range of 85.8 dB/Hz2/3. This operation suppresses the noise floor of the DMLD carried QPSK-OFDM spectrum by 5 dB. The optical receiving power is optimized to restrict the power fading effect for improving the bit error rate to 1.9 × 10-3 and the receiving power penalty to 1.1 dB. Such DMLD based hybrid architecture for 60-GHz MMW fiber-wireless access can directly cover the current optical and wireless networks for next-generation indoor and short-reach mobile communications.

  7. Millimeter Wave Multi-user Performance Evaluation Based on Measured Channels with Virtual Antenna Array Channel Sounder

    DEFF Research Database (Denmark)

    Mbugua, Allan Wainaina; Fan, Wei; Ji, Yilin

    2018-01-01

    Virtual antenna arrays are versatile and costeffective tools for millimeter-wave (mm-wave) channel characterization. Massive sampling of the channel in space with virtual antenna arrays enables high spatial resolution in channel sounding. In this paper a uniform cubic array (UCuA) is used...... rectangular array (URA) which acts as the base station (BS) and with users under LOS and OLOS conditions. Results show interference suppression with zero forcing beamforming (ZF-BF) performs well even in critical multi-user scenarios based on the measured channels, i.e. a scenario with closely spaced users...

  8. Switchable Multi-Frequency MMIC Oscillator for the 60 GHz Millimeter Wave Band

    Science.gov (United States)

    Taillefer, Eddy; Kitazawa, Shoichi; Ueba, Masazumi

    We propose a proof-of-concept of a switchable multi-frequency MMIC (monolithic microwave integrated circuit) oscillator device, operating in the 60GHz millimeter wave band, which is implemented in GaAs p-HEMT transistor technology. Oscillators that can switch between two frequencies have been designed, fabricated and evaluated. The oscillator uses a cross-coupled FET topology, combined with a bent asymmetric coplanar stripline for the resonator, and a switched-capacitor for the frequency switching components. The oscillator generates two oscillations at ƒ/2 and ƒ where ƒ is the target frequency of around 60GHz. The switchable oscillator has been demonstrated for the range of frequency from 44GHz to 68.9GHz. Moreover, the designed oscillator exhibits a wide-band negative resistance property that allows fabricating switchable oscillators covering the 50 to 75GHz V-band. An evaluated switchable oscillator delivers -17.09dBm and -13.72dBm output power at 62.45GHz and 64.78GHz, for a supplied power of 40.6mW and 39.1mW, respectively.

  9. Gigabit radio-over-fiber link for converged baseband and millimeter-wave band signal transmission using cascaded injection-locked Fabry-Pérot laser diodes.

    Science.gov (United States)

    Hong, Moon-Ki; Won, Yong-Yuk; Han, Sang-Kook

    2009-05-11

    A novel scheme, for both baseband and millimeter-wave band gigabit data transmission in radio-over-fiber system, is proposed and experimentally demonstrated by using cascaded injection-locked Fabry- Pérot laser diodes. It was able to improve suppression ratio of carrier suppressed signal using the cascaded injection-locking. The suppression ratio improvement of the optical carrier suppressed signal of 20 dB was verified. Applying this mechanism, 60-GHz millimeter-wave carrier of enhanced signal quality could be accomplished. Its peak power and phase noise were obtained as -40 dBm and -103.5 dBm/Hz respectively, which was suitable for 60-GHz data transmission. In addition, a successful bidirectional transmission of 1.25-Gbps wired and wireless data was achieved by adopting remodulation technique using a gain-saturated reflective semiconductor optical amplifier for uplink.

  10. Enabling technologies for millimeter-wave radio-over-fiber systems in next generation heterogeneous mobile access networks

    Science.gov (United States)

    Zhang, Junwen; Yu, Jianjun; Wang, Jing; Xu, Mu; Cheng, Lin; Lu, Feng; Shen, Shuyi; Yan, Yan; Cho, Hyunwoo; Guidotti, Daniel; Chang, Gee-kung

    2017-01-01

    Fifth-generation (5G) wireless access network promises to support higher access data rate with more than 1,000 times capacity with respect to current long-term evolution (LTE) systems. New radio-access-technologies (RATs) based on higher carrier frequencies to millimeter-wave (MMW) radio-over-fiber, and carrier-aggregation (CA) using multi-band resources are intensively studied to support the high data rate access and effectively use of frequency resources in heterogeneous mobile network (Het-Net). In this paper, we investigate several enabling technologies for MMW RoF systems in 5G Het-Net. Efficient mobile fronthaul (MFH) solutions for 5G centralized radio access network (C-RAN) and beyond are proposed, analyzed and experimentally demonstrated based on the analog scheme. Digital predistortion based on memory polynomial for analog MFH linearization are presented with improved EVM performances and receiver sensitivity. We also propose and experimentally demonstrate a novel inter-/intra- RAT CA scheme for 5G Het- Net. The real-time standard 4G-LTE signal is carrier-aggregated with three broadband 60GHz MMW signals based on proposed optical-domain band-mapping method. RATs based on new waveforms have also been studied here to achieve higher spectral-efficiency (SE) in asynchronous environments. Full-duplex asynchronous quasi-gapless carrier aggregation scheme for MMW ROF inter-/intra-RAT based on the FBMC is also presented with 4G-LTE signals. Compared with OFDM-based signals with large guard-bands, FBMC achieves higher spectral-efficiency with better EVM performance at less received power and smaller guard-bands.

  11. Transcriptome analysis reveals the contribution of thermal and the specific effects in cellular response to millimeter wave exposure.

    Directory of Open Access Journals (Sweden)

    Denis Habauzit

    Full Text Available Radiofrequency radiations constitute a new form of environmental pollution. Among them, millimeter waves (MMW will be widely used in the near future for high speed communication systems. This study aimed therefore to evaluate the biocompatibility of MMW at 60 GHz. For this purpose, we used a whole gene expression approach to assess the effect of acute 60 GHz exposure on primary cultures of human keratinocytes. Controls were performed to dissociate the electromagnetic from the thermal effect of MMW. Microarray data were validated by RT-PCR, in order to ensure the reproducibility of the results. MMW exposure at 20 mW/cm2, corresponding to the maximum incident power density authorized for public use (local exposure averaged over 1 cm2, led to an increase of temperature and to a strong modification of keratinocyte gene expression (665 genes differentially expressed. Nevertheless, when temperature is artificially maintained constant, no modification in gene expression was observed after MMW exposure. However, a heat shock control did not mimic exactly the MMW effect, suggesting a slight but specific electromagnetic effect under hyperthermia conditions (34 genes differentially expressed. By RT-PCR, we analyzed the time course of the transcriptomic response and 7 genes have been validated as differentially expressed: ADAMTS6, NOG, IL7R, FADD, JUNB, SNAI2 and HIST1H1A. Our data evidenced a specific electromagnetic effect of MMW, which is associated to the cellular response to hyperthermia. This study raises the question of co-exposures associating radiofrequencies and other environmental sources of cellular stress.

  12. Low-latency fiber-millimeter-wave system for future mobile fronthauling

    Science.gov (United States)

    Tien Dat, Pham; Kanno, Atsushi; Yamamoto, Naokatsu; Kawanishi, Tetsuya

    2016-02-01

    A seamless combination of fiber and millimeter-wave (MMW) systems can be very attractive for future heterogeneous mobile networks such as 5G because of its flexibility and high bandwidth. Analog mobile signal transmission over seamless fiber-MMW systems is very promising to reduce the latency and the required band-width, and to simplify the systems. However, stable and high-performance seamless systems are indispensable to conserve the quality of the analog signal transmission. In this paper, we present several technologies to develop such seamless fiber-MMW systems. In the downlink direction, a high-performance system can be realized using a high-quality optical MMW signal generator and a self-homodyne MMW signal detector. In the uplink direction, a cascade of radio-on-radio and radio-over-fiber systems using a burst-mode optical amplifier can support bursty radio signal transmission. A full-duplex transmission with negligible interference effects can be realized using frequency multiplexing in the radio link and wavelength-division multiplexing in the optical link. A high-spectral efficiency MMW-over-fiber system using an intermediate frequency-over-fiber system and a high-quality remote delivery of a local oscillator signal is highly desirable to reduce the costs.

  13. A Study on Suppression of Electromagnetic Radiation Noise from Wireless Module in Millimeter-Wave Band by Using Alumina Containing Carbon Black

    Science.gov (United States)

    Takase, Yasuharu; Hashimoto, Osamu; Matsumoto, Kouta; Kumada, Taketo

    The unwanted electromagnetic(EM) radiation wave generated from the wireless module in millimeter-wave band used for the car radar influences some error and performance degradation of electronic equipments. In this paper, to reduce this unwanted EM wave, a optimal design to add the function of EM wave absorption to the lid for the module is examined. Therefore the alumina containing carbon black is used as a wave absorption material of the lid. The absorption of 20dB or more is obtained as a measured result with the cover added the EM wave absorption function in 60GHz. Furthermore, we analyzed the wireless module in millimeter-wave band by using the designed material for the lid. It is clarified that the radiation and the reflection electric power are greatly suppressed by loss electric power of the lid. Therefore, the effective data for suppressing the unwanted EM radiation noise from wireless module in millimeter-wave band can be provided.

  14. Research on Ground Motion Metal Target Based on Rocket Projectile by Using Millimeter Wave Radiometer Technology

    Directory of Open Access Journals (Sweden)

    Zhang Dongyang

    2014-06-01

    Full Text Available How to detect the ground motion metal target effectively is an important guarantee for precision strike in the process of Rocket Projectile flight. Accordingly and in view of the millimeter- wave radiation characteristic of the ground motion metal target, a mathematical model was established based on Rocket Projectile about millimeter-wave detection to the ground motion metal target. Through changing various parameters in the process of Rocket Projectile flight, the detection model was studied by simulation. The parameters variation and effective range of millimeter wave radiometer were obtained in the process of rotation and horizontal flight. So a certain theoretical basis was formed for the precision strike to the ground motion metal target.

  15. Large-scale transmission-type multifunctional anisotropic coding metasurfaces in millimeter-wave frequencies

    Science.gov (United States)

    Cui, Tie Jun; Wu, Rui Yuan; Wu, Wei; Shi, Chuan Bo; Li, Yun Bo

    2017-10-01

    We propose fast and accurate designs to large-scale and low-profile transmission-type anisotropic coding metasurfaces with multiple functions in the millimeter-wave frequencies based on the antenna-array method. The numerical simulation of an anisotropic coding metasurface with the size of 30λ × 30λ by the proposed method takes only 20 min, which however cannot be realized by commercial software due to huge memory usage in personal computers. To inspect the performance of coding metasurfaces in the millimeter-wave band, the working frequency is chosen as 60 GHz. Based on the convolution operations and holographic theory, the proposed multifunctional anisotropic coding metasurface exhibits different effects excited by y-polarized and x-polarized incidences. This study extends the frequency range of coding metasurfaces, filling the gap between microwave and terahertz bands, and implying promising applications in millimeter-wave communication and imaging.

  16. THE CHROMOSPHERIC SOLAR MILLIMETER-WAVE CAVITY ORIGINATES IN THE TEMPERATURE MINIMUM REGION

    Energy Technology Data Exchange (ETDEWEB)

    De la Luz, Victor [Instituto Nacional de Astrofisica, Optica y Electronica, Tonantzintla, Puebla, Mexico, Apdo. Postal 51 y 216, 72000 (Mexico); Raulin, Jean-Pierre [CRAAM, Universidade Presbiteriana Mackenzie, Sao Paulo, SP 01302-907 (Brazil); Lara, Alejandro [Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, Mexico 04510 (Mexico)

    2013-01-10

    We present a detailed theoretical analysis of the local radio emission at the lower part of the solar atmosphere. To accomplish this, we have used a numerical code to simulate the emission and transport of high-frequency electromagnetic waves from 2 GHz up to 10 THz. As initial conditions, we used VALC, SEL05, and C7 solar chromospheric models. In this way, the generated synthetic spectra allow us to study the local emission and absorption processes with high resolution in both altitude and frequency. Associated with the temperature minimum predicted by these models, we found that the local optical depth at millimeter wavelengths remains constant, producing an optically thin layer that is surrounded by two layers of high local emission. We call this structure the Chromospheric Solar Millimeter-wave Cavity (CSMC). The temperature profile, which features temperature minimum layers and a subsequent temperature rise, produces the CSMC phenomenon. The CSMC shows the complexity of the relation between the theoretical temperature profile and the observed brightness temperature and may help us to understand the dispersion of the observed brightness temperature in the millimeter wavelength range.

  17. Simultaneous measurement of temperature and emissivity of lunar regolith simulant using dual-channel millimeter-wave radiometry

    Energy Technology Data Exchange (ETDEWEB)

    McCloy, J. S.; Sundaram, S. K.; Matyas, J.; Woskov, P. P.

    2011-01-01

    Millimeter wave (MMW) radiometry can be used for simultaneous measurement of emissivity and temperature of materials under extreme environments (high temperature, pressure, and corrosive environments). The state-of-the-art dual channel MMW passive radiometer with active interferometric capabilities at 137 GHz described here allows for radiometric measurements of sample temperature and emissivity up to at least 1600 °C with simultaneous measurement of sample surface dynamics. These capabilities have been used to demonstrate dynamic measurement of melting of powders of simulated lunar regolith and static measurement of emissivity of solid samples. The paper presents the theoretical background and basis for the dual-receiver system, describes the hardware in detail, and demonstrates the data analysis. Post-experiment analysis of emissivity versus temperature allows further extraction from the radiometric data of millimeter wave viewing beam coupling factors, which provide corroboratory evidence to the interferometric data of the process dynamics observed. Finally, these results show the promise of the MMW system for extracting quantitative and qualitative process parameters for industrial processes and access to real-time dynamics of materials behavior in extreme environments.

  18. Inspection Of Spray On Foam Insulation (SOFI) Using and Microwave and Millimeter Wave Synthetic Aperture Focusing and Holography

    Science.gov (United States)

    Hepburn, F. L.; Case, J. T.; Zoughi, R.

    2006-01-01

    The Space Shuttle Columbia's catastrophic failure is thought to have been caused by a dislodged piece of external tank spray on foam insulation (SOFI) striking the left wing of the orbiter causing significant damage to some of the reinforced carbon/carbon leading edge wing panels [1]. Microwave and millimeter wave nondestructive evaluation methods have shown great potential for inspecting SOFI for the purpose of detecting anomalies such as small air voids that may cause separation of the SOFI from the external tank during a launch [2,3]. These methods are capable of producing relatively high-resolution images of the interior of SOFI. Although effective, there are some advantages in using synthetic focusing methods as opposed to real focusing methods such as reduced probe size, the ability to determine depth from multiple views, and the ability to slice images due to sufficient range resolution. To this end, synthetic aperture focusing techniques (SAFT) were first pursued for this purpose and later wide-band microwave holography was implemented [4-7]. This paper presents the results of this investigation using frequency domain synthetic aperture focusing technique (FD-SAFT) and wide-band microwave holography methods illustrating their potential capabilities for inspecting the space shuttle's SOFI at millimeter wave frequencies.

  19. 64-GHz millimeter-wave photonic generation with a feasible radio over fiber system

    Science.gov (United States)

    Al-Dabbagh, Rasha K.; Al-Raweshidy, Hamed S.

    2017-02-01

    A full-duplex radio over fiber (RoF) link with the generation of a 64-GHz millimeter wave (mm-wave) is investigated. This system is proposed as a solution to cope with the demands of a multi-Gb/s data transmission in the fifth generation (5G) and beyond for small cell networks. Cost reduction and performance improvement are achieved by simplifying the mm-wave generation method with an RoF technique. High-frequency radio signals are considered challenging in the electrical generation domain; therefore, our photonic generation method is introduced and examined. RoF design is proposed for mm-wave generation using both phase modulation and the effect of stimulated Brillouin scattering in the optical fiber for the first time. RoF system with transmission rates of 5 Gb/s is successfully achieved. In our scheme, one laser source is utilized and a fiber Bragg grating is used for wavelength reuse for the uplink connection. Stable mm-wave RoF link is successfully achieved in up to a 100-km fiber link length with high quality carrier. Simulation results show a reduction in fiber nonlinearity effects and the mm-wave signal has low noise equal to -75 dBm. This study ensures a practical mm-wave RoF link, and it could be appropriate for small cell 5G networks by reducing the installation cost.

  20. Connectivity Analysis of Millimeter-Wave Device-to-Device Networks with Blockage

    Directory of Open Access Journals (Sweden)

    Haejoon Jung

    2016-01-01

    Full Text Available We consider device-to-device (D2D communications in millimeter-wave (mm Wave for the future fifth generation (5G cellular networks. While the mm Wave systems can support multiple D2D pairs simultaneously through beamforming with highly directional antenna arrays, the mm Wave channel is significantly more susceptible to blockage compared to microwave; mm Wave channel studies indicate that if line-of-sight (LoS paths are blocked, reliable mm Wave communications may not be achieved for high data-rate applications. Therefore, assuming that an outage occurs in the absence of the LoS path between two wireless devices by obstructions, we focus on connectivity of the mm Wave D2D networks. We consider two types of D2D communications: direct and indirect schemes. The connectivity performances of the two schemes are investigated in terms of (i the probability to achieve a fully connected network PFC and (ii the average number of reliably connected devices γ. Through analysis and simulation, we show that, as the network size increases, PFC and γ decrease. Also, PFC and γ decrease, when the blockage parameter increases. Moreover, simulation results indicate that the hybrid direct and indirect scheme can improve both PFC and γ up to about 35% compared to the nonhybrid scheme.

  1. A 94-GHz Millimeter-Wave Sensor for Speech Signal Acquisition

    Directory of Open Access Journals (Sweden)

    Jianqi Wang

    2013-10-01

    Full Text Available High frequency millimeter-wave (MMW radar-like sensors enable the detection of speech signals. This novel non-acoustic speech detection method has some special advantages not offered by traditional microphones, such as preventing strong-acoustic interference, high directional sensitivity with penetration, and long detection distance. A 94-GHz MMW radar sensor was employed in this study to test its speech acquisition ability. A 34-GHz zero intermediate frequency radar, a 34-GHz superheterodyne radar, and a microphone were also used for comparison purposes. A short-time phase-spectrum-compensation algorithm was used to enhance the detected speech. The results reveal that the 94-GHz radar sensor showed the highest sensitivity and obtained the highest speech quality subjective measurement score. This result suggests that the MMW radar sensor has better performance than a traditional microphone in terms of speech detection for detection distances longer than 1 m. As a substitute for the traditional speech acquisition method, this novel speech acquisition method demonstrates a large potential for many speech related applications.

  2. Monolithic millimeter-wave diode array beam controllers: Theory and experiment

    Science.gov (United States)

    Sjogren, L. B.; Liu, H.-X. L.; Wang, F.; Liu, T.; Wu, W.; Qin, X.-H.; Chung, E.; Domier, C. W.; Luhmann, N. C., Jr.; Maserjian, J.

    1992-01-01

    In the current work, multi-function beam control arrays have been fabricated and have successfully demonstrated amplitude control of transmitted beams in the W and D bands (75-170 GHz). While these arrays are designed to provide beam control under DC bias operation, new designs for high-speed electronic and optical control are under development. These arrays will fill a need for high-speed watt-level beam switches in pulsed reflectometer systems under development for magnetic fusion plasma diagnostics. A second experimental accomplishment of the current work is the demonstration in the 100-170 GHz (D band) frequency range of a new technique for the measurement of the transmission phase as well as amplitude. Transmission data can serve as a means to extract ('de-embed') the grid parameters; phase information provides more complete data to assist in this process. Additional functions of the array beam controller yet to be tested include electronically controlled steering and focusing of a reflected beam. These have application in the areas of millimeter-wave electronic scanning radar and reflectometry, respectively.

  3. Photonic Implementation of 4-QAM/QPSK Electrical Modulation at Millimeter-Wave Frequency

    DEFF Research Database (Denmark)

    Yu, Xianbin; Jensen, Jesper Bevensee; Tafur Monroy, Idelfonso

    2008-01-01

    We propose a photonic method for generating millimeter-wave 4-QAM/QPSK modulated signals. The method is based on optical phase modulation by multilevel electrical signals and optical carrier-suppression. Simulation results are presented for 2.5 Gsymbol/s 4-QAM and QPSK signals at a 36 GHz carrier....... Furthermore, this method can be extended to generate millimeter-wave m-PSK signals and can be incorporated into broadband radio-over-fiber systems to support wireless/ wireline converged access network....

  4. Coherent laser-millimeter-wave interactions en route to coherent population transfer.

    Science.gov (United States)

    Grimes, David D; Barnum, Timothy J; Zhou, Yan; Colombo, Anthony P; Field, Robert W

    2017-10-14

    We demonstrate coherent two-photon population transfer to Rydberg states of barium atoms using a combination of a pulsed dye laser and a chirped-pulse millimeter-wave spectrometer. Numerical calculations, using a density matrix formalism, reproduce our experimental results and explain the factors responsible for the observed fractional population transferred, optimal experimental conditions, and possibilities for future improvements. The long coherence times associated with the millimeter-wave radiation aid in creating coherence between the ground state and Rydberg states, but higher-coherence laser sources are required to achieve stimulated Raman adiabatic passage and for applications to molecules.

  5. Microwave and Millimeter Wave Imaging of the Space Shuttle External Fuel Tank Spray on Foam Insulation (SOFI) using Synthetic Aperture Focusing Techniques (SAFT}

    Science.gov (United States)

    Case, J. T.; Robbins, J.; Kharkivskiy, S.; Hepburn, F.; Zoughi, R.

    2005-01-01

    The Space Shuttle Columbia s catastrophic failure is thought to have been caused by a dislodged piece of external tank spray on foam insulation (SOFI) striking the left wing of the orbiter causing significant damage to some of the reinforced carbodcarbon leading edge wing panels. Microwave and millimeter wave nondestructive evaluation methods have shown great potential for inspecting SOFI for the purpose of detecting anomalies such as small air voids that may cause separation of the SOFI from the external tank during a launch. These methods are capable of producing relatively high-resolution images of the interior of SOFI particularly when advanced imaging algorithms are incorporated into the overall system. To this end, synthetic aperture focusing techniques (SAFT) are being developed. This paper presents some of the preliminary results of this investigation using SAFT-based methods and microwave holography at relatively low frequencies illustrating their potential capabilities for operation at millimeter wave frequencies.

  6. Microwave and Millimeter Wave Imaging of the Space Shuttle External Fuel Tank Spray on Foam Insulation (SOFI) Using Synthetic Aperture Focusing Techniques (SAFT)

    Science.gov (United States)

    Case, J. T.; Robbins, J.; Kharkovsky, S.; Hepburn, F.; Zoughi, R.

    2006-03-01

    The Space Shuttle Columbia's catastrophic failure is thought to have been caused by a dislodged piece of external tank spray on foam insulation (SOFI) striking the left wing of the orbiter causing significant damage to some of the reinforced carbon/carbon leading edge wing panels. Microwave and millimeter wave nondestructive evaluation methods have shown great potential for inspecting SOFI for the purpose of detecting anomalies such as small air voids that may cause separation of the SOFI from the external tank during a launch. These methods are capable of producing relatively high-resolution images of the interior of SOFI particularly when advanced imaging algorithms are incorporated into the overall system. To this end, synthetic aperture focusing techniques (SAFT) are being developed. This paper presents some of the preliminary results of this investigation using SAFT-based methods and microwave holography at relatively low frequencies illustrating their potential capabilities for operation at millimeter wave frequencies.

  7. Embedded electronics for a video-rate distributed aperture passive millimeter-wave imager

    Science.gov (United States)

    Curt, Petersen F.; Bonnett, James; Schuetz, Christopher A.; Martin, Richard D.

    2013-05-01

    Optical upconversion for a distributed aperture millimeter wave imaging system is highly beneficial due to its superior bandwidth and limited susceptibility to EMI. These features mean the same technology can be used to collect information across a wide spectrum, as well as in harsh environments. Some practical uses of this technology include safety of flight in degraded visual environments (DVE), imaging through smoke and fog, and even electronic warfare. Using fiber-optics in the distributed aperture poses a particularly challenging problem with respect to maintaining coherence of the information between channels. In order to capture an image, the antenna aperture must be electronically steered and focused to a particular distance. Further, the state of the phased array must be maintained, even as environmental factors such as vibration, temperature and humidity adversely affect the propagation of the signals through the optical fibers. This phenomenon cannot be avoided or mitigated, but rather must be compensated for using a closed-loop control system. In this paper, we present an implementation of embedded electronics designed specifically for this purpose. This novel architecture is efficiently small, scalable to many simultaneously operating channels and sufficiently robust. We present our results, which include integration into a 220 channel imager and phase stability measurements as the system is stressed according to MIL-STD-810F vibration profiles of an H-53E heavy-lift helicopter.

  8. A Novel Method for Speech Acquisition and Enhancement by 94 GHz Millimeter-Wave Sensor.

    Science.gov (United States)

    Chen, Fuming; Li, Sheng; Li, Chuantao; Liu, Miao; Li, Zhao; Xue, Huijun; Jing, Xijing; Wang, Jianqi

    2015-12-31

    In order to improve the speech acquisition ability of a non-contact method, a 94 GHz millimeter wave (MMW) radar sensor was employed to detect speech signals. This novel non-contact speech acquisition method was shown to have high directional sensitivity, and to be immune to strong acoustical disturbance. However, MMW radar speech is often degraded by combined sources of noise, which mainly include harmonic, electrical circuit and channel noise. In this paper, an algorithm combining empirical mode decomposition (EMD) and mutual information entropy (MIE) was proposed for enhancing the perceptibility and intelligibility of radar speech. Firstly, the radar speech signal was adaptively decomposed into oscillatory components called intrinsic mode functions (IMFs) by EMD. Secondly, MIE was used to determine the number of reconstructive components, and then an adaptive threshold was employed to remove the noise from the radar speech. The experimental results show that human speech can be effectively acquired by a 94 GHz MMW radar sensor when the detection distance is 20 m. Moreover, the noise of the radar speech is greatly suppressed and the speech sounds become more pleasant to human listeners after being enhanced by the proposed algorithm, suggesting that this novel speech acquisition and enhancement method will provide a promising alternative for various applications associated with speech detection.

  9. A Novel Unit Cell for Active Switches in the Millimeter-Wave Frequency Range

    Science.gov (United States)

    Müller, Daniel; Scherer, Gunnar; Lewark, Ulrich J.; Massler, Hermann; Wagner, Sandrine; Tessmann, Axel; Leuther, Arnulf; Zwick, Thomas; Kallfass, Ingmar

    2018-02-01

    This paper presents a novel transistor unit cell which is intended to realize compact active switches in the high millimeter-wave frequency range. The unit cell consists of the combination of shunt and common gate transistor within a four-finger transistor cell, achieving gain in the amplifying state as well as good isolation in the isolating state. Gate width-dependent characteristics of the unit cell as well as the design of actual switch implementations are discussed in detail. To verify the concept, two switches, a single pole double throw (SPDT) switch and single pole quadruple throw (SP4T) switch, intended for the WR3 frequency range (220-325 GHz) were manufactured and characterized. The measured gain at 250 GHz is 4.6 and 2.2 dB for the SPDT and SP4T switch, respectively. An isolation of more than 24 dB for the SPDT switch and 12.8 dB for the SP4T switch was achieved.

  10. A Novel Method for Speech Acquisition and Enhancement by 94 GHz Millimeter-Wave Sensor

    Directory of Open Access Journals (Sweden)

    Fuming Chen

    2015-12-01

    Full Text Available In order to improve the speech acquisition ability of a non-contact method, a 94 GHz millimeter wave (MMW radar sensor was employed to detect speech signals. This novel non-contact speech acquisition method was shown to have high directional sensitivity, and to be immune to strong acoustical disturbance. However, MMW radar speech is often degraded by combined sources of noise, which mainly include harmonic, electrical circuit and channel noise. In this paper, an algorithm combining empirical mode decomposition (EMD and mutual information entropy (MIE was proposed for enhancing the perceptibility and intelligibility of radar speech. Firstly, the radar speech signal was adaptively decomposed into oscillatory components called intrinsic mode functions (IMFs by EMD. Secondly, MIE was used to determine the number of reconstructive components, and then an adaptive threshold was employed to remove the noise from the radar speech. The experimental results show that human speech can be effectively acquired by a 94 GHz MMW radar sensor when the detection distance is 20 m. Moreover, the noise of the radar speech is greatly suppressed and the speech sounds become more pleasant to human listeners after being enhanced by the proposed algorithm, suggesting that this novel speech acquisition and enhancement method will provide a promising alternative for various applications associated with speech detection.

  11. A 0.1-μm MHEMT millimeter-wave IC technology designed for manufacturability

    Science.gov (United States)

    Rohdin, Hans; Wakita, Arlene; Nagy, Avelina; Robbins, Virginia; Moll, Nick; Su, Chung-yi

    1999-08-01

    We describe and discuss our approach to improved manufacturability of millimeter-wave InP-type HEMT IC technology. The main ingredients are the use of (1) GaAs (rather than InP) as substrate, with a buffer that grades the lattice constant to that of the high-mobility Ga 0.47In 0.53As channel; (2) low-resistance non-alloyed ohmic contacts with good reliability and reproducibility; (3) an e-beam process that produces 0.1-μm T-gate fingers with one exposure and (4) two-step selective etching of the gate trough for good uniformity. The process is compatible with standard GaAs FET IC front and back end unit processes, including backside vias. The yield, uniformity and performance of devices and circuits made on this metamorphic (MHEMT) material are consistently as good as those we get using InP substrates. The reliability of our devices, whether made on GaAs or InP substrates, is limited by impact ionization in the channel, which has also been linked to Rd-degradation and burnout. At low-noise drain bias ( Vd=1 V), where the impact ionization is small, we have demonstrated reliability, i.e. extrapolated MTTF at 125°C channel temperature is >10 6 h. This is as good as FETs made on InP substrates.

  12. Protein changes in macrophages induced by plasma from rats exposed to 35 GHz millimeter waves.

    Science.gov (United States)

    Sypniewska, Roza K; Millenbaugh, Nancy J; Kiel, Johnathan L; Blystone, Robert V; Ringham, Heather N; Mason, Patrick A; Witzmann, Frank A

    2010-12-01

    A macrophage assay and proteomic screening were used to investigate the biological activity of soluble factors in the plasma of millimeter wave-exposed rats. NR8383 rat macrophages were incubated for 24 h with 10% plasma from male Sprague-Dawley rats that had been exposed to sham conditions, or exposed to 42 °C environmental heat or 35 GHz millimeter waves at 75 mW/cm² until core temperature reached 41.0 °C. Two-dimensional polyacrylamide gel electrophoresis, image analysis, and Western blotting were used to analyze approximately 600 protein spots in the cell lysates for changes in protein abundance and levels of 3-nitrotyrosine, a marker of macrophage stimulation. Proteins of interest were identified using peptide mass fingerprinting. Compared to plasma from sham-exposed rats, plasma from environmental heat- or millimeter wave-exposed rats increased the expression of 11 proteins, and levels of 3-nitrotyrosine in seven proteins, in the NR8383 cells. These altered proteins are associated with inflammation, oxidative stress, and energy metabolism. Findings of this study indicate both environmental heat and 35 GHz millimeter wave exposure elicit the release of macrophage-activating mediators into the plasma of rats.

  13. Atropisomerism in bisphenols: free jet absorption millimeter wave study of 2,2$prime;-biphenol

    Science.gov (United States)

    Ottaviani, Paolo; Maris, Assimo; Caminati, Walther

    2004-06-01

    The rotational spectrum of 2,2'-biphenol has been investigated by millimeter wave absorption free jet spectroscopy. The two sides of the phenyl rings with attached the hydroxyl group form a dihedral angle of 112.7°. Each hydroxyl group is nearly co-planar to the ring to which it belongs, and points towards the π system of the adjacent ring.

  14. On the mechanisms of interaction of low-intensity millimeter waves with biological objects

    Energy Technology Data Exchange (ETDEWEB)

    Betskii, O.V.

    1994-07-01

    The interaction of low-intensity millimeter-band electromagnetic waves with biological objects is examined. These waves are widely used in medical practice as a means of physiotherapy for the treatment of various human disorders. Principal attention is given to the mechanisms through which millimeter waves act on the human organism.

  15. A Continuous Millimeter-Wave Imaging Scanner for Art Conservation Science

    Directory of Open Access Journals (Sweden)

    Ayesha Younus

    2011-01-01

    Full Text Available A monochromatic continuous millimeter-wave imaging system coupled with an infrared temperature sensor has been used to investigate artistic objects such as painting artworks or antiquities preserved at the museum of Aquitaine. Especially, 2D and 3D analyses have been performed in order to reveal the internal structure of a nearly 3500-year-old sealed Egyptian jar.

  16. A Continuous Millimeter-Wave Imaging Scanner for Art Conservation Science

    OpenAIRE

    Ayesha Younus; Jean-Pascal Caumes; Simon Salort; Bruno Chassagne; Christophe Pradère; Alain Dautant; Anne Ziéglé; Emmanuel Abraham

    2011-01-01

    International audience; A monochromatic continuous millimeter-wave imaging system coupled with an infrared temperature sensor has been used to investigate artistic objects such as painting artworks or antiquities preserved at the museum of Aquitaine. Especially, 2D and 3D analyses have been performed in order to reveal the internal structure of a nearly 3500-year-old sealed Egyptian jar.

  17. A Novel HBT Frequency Doubler Design for Millimeter-Wave Applications

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Krozer, Viktor; Vidkjær, Jens

    2006-01-01

    In this paper we presents a novel HBT frequency doubler design for millimeter-wave application. A HBT frequency doubler theory is described which leads to accurate design equations for optimal performance. The developed theory shows that an optimal HBT frequency doubler can be achieved using...

  18. Low-cost millimeter-wave transceiver module using SMD packaged MMICs

    NARCIS (Netherlands)

    Heijningen, M. van; Gauthier, G.

    2004-01-01

    This paper presents a novel approach to realize low-cost millimeter-wave modules using only SMD packaged MMICs integrated on a single organic substrate. This approach is demonstrated on a 38 GHz transceiver module for point-to-point LMDS communication systems. The required SMD package technology and

  19. Low-Cost Millimeter-Wave Transceiver Module using SMD packaged MMICs.

    NARCIS (Netherlands)

    2004-01-01

    This paper presents a novel approach to realize low-cost millimeter-wave modules using only SMD packaged MMICs integrated on a single organic substrate. This approach is demonstrated on a 38 GHz transceiver module for point-to-point LMDS communication systems. The required SMD package technology and

  20. Photoluminescence enhancement in manganese-doped magnesium stannate phosphors synthesized by millimeter-wave irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kitaura, M., E-mail: kitaura@fukui-nct.ac.j [Fukui National College of Technology, Sabae, Fukui 916-8507 (Japan); Tani, S.; Mitsudo, S. [Research Center for Development of Far Infrared Region, University of Fukui, Fukui 910-8507 (Japan); Fukui, K. [Department of Electrical and Electronics Engineering, University of Fukui, Fukui 910-8507 (Japan)

    2010-03-15

    We have investigated photoluminescence (PL) of Mg{sub 2}SnO{sub 4}:Mn phosphors synthesized by the irradiation with millimeter-wave of 24 GHz. The PL spectrum at room temperature is dominated by a green band peaking at 500 nm, suggesting the existence of tetrahedral Mn{sup 2+} sites. When the phosphors are grown by the millimeter-wave heating, the 500 nm band is so much intense compared to those by the electric furnace heating. To clarify the origin of the PL enhancement, we have carried out the measurements of scanning electron microscope (SEM) and electron spin resonance (ESR). The SEM image exhibits the growth of small round particles with an average size of 1.6 {mu}m. Such well-grown micron-sized particles were not observed under the electric furnace heating. The ESR spectra exhibit six prominent lines, the intensity of which becomes greater for the phosphors obtained by the millimeter-wave heating. From this observation, it is supposed that the PL enhancement is mainly due to the increase in the number of tetrahedral Mn{sup 2+} sites. Therefore, the millimeter-wave heating has an important advantage over the electric furnace heating in the synthesis of Mg{sub 2}SnO{sub 4}:Mn phosphors.

  1. Fast ion millimeter wave collective Thomson scattering diagnostics on TEXTOR and ASDEX upgrades

    DEFF Research Database (Denmark)

    Michelsen, S.; Korsholm, Søren Bang; Bindslev, H.

    2004-01-01

    Collective Thomson scattering (CTS) diagnostic systems for measuring fast ions in TEXTOR and ASDEX Upgrade are described in this article. Both systems use millimeter waves generated by gyrotrons as probing radiation and the scattered radiation is detected with heterodyne receivers having 40...

  2. Millimeter-wave-induced fluxon pair creation in flux-flow Josephson oscillators

    DEFF Research Database (Denmark)

    Ustinov, A. V.; Mygind, Jesper; Pedersen, Niels Falsig

    1992-01-01

    We now observe a new type of dynamical state in long Josephson junctions. Millimeter-wave irradiation in the frequency range fext=62–77 GHz, was applied to a long junction biased in the flux-flow mode. Besides an ordinary flux-flow step satellite, flux-flow steps with voltage spacing corresponding...

  3. A Novel Reconfigurable Ultra-broadband Millimeter-wave Photonic Harmonic Down-converter

    DEFF Research Database (Denmark)

    Pang, Xiaodan; Zhao, Ying; Deng, Lei

    2011-01-01

    We propose a novel ultra-broadband reconfigurable photonic harmonic mixer functioning as a millimeter-wave downconverter for multigigabit wireless applications. Based on frequency conversion implemented by an optical frequency comb generator, the photonic mixer is able to operate up to 100GHz...

  4. Millimeter-Wave Wireless LAN and Its Extension toward 5G Heterogeneous Networks

    Science.gov (United States)

    Sakaguchi, Kei; Mohamed, Ehab Mahmoud; Kusano, Hideyuki; Mizukami, Makoto; Miyamoto, Shinichi; Rezagah, Roya E.; Takinami, Koji; Takahashi, Kazuaki; Shirakata, Naganori; Peng, Hailan; Yamamoto, Toshiaki; Nanba, Shinobu

    Millimeter-wave (mmw) frequency bands, especially 60 GHz unlicensed band, are considered as a promising solution for gigabit short range wireless communication systems. IEEE standard 802.11ad, also known as WiGig, is standardized for the usage of the 60 GHz unlicensed band for wireless local area networks (WLANs). By using this mmw WLAN, multi-Gbps rate can be achieved to support bandwidth-intensive multimedia applications. Exhaustive search along with beamforming (BF) is usually used to overcome 60 GHz channel propagation loss and accomplish data transmissions in such mmw WLANs. Because of its short range transmission with a high susceptibility to path blocking, multiple number of mmw access points (APs) should be used to fully cover a typical target environment for future high capacity multi-Gbps WLANs. Therefore, coordination among mmw APs is highly needed to overcome packet collisions resulting from un-coordinated exhaustive search BF and to increase the total capacity of mmw WLANs. In this paper, we firstly give the current status of mmw WLANs with our developed WiGig AP prototype. Then, we highlight the great need for coordinated transmissions among mmw APs as a key enabler for future high capacity mmw WLANs. Two different types of coordinated mmw WLAN architecture are introduced. One is the distributed antenna type architecture to realize centralized coordination, while the other is an autonomous coordination with the assistance of legacy Wi-Fi signaling. Moreover, two heterogeneous network (HetNet) architectures are also introduced to efficiently extend the coordinated mmw WLANs to be used for future 5th Generation (5G) cellular networks.

  5. Comparison of blood pressure and thermal responses in rats exposed to millimeter wave energy or environmental heat.

    Science.gov (United States)

    Millenbaugh, Nancy J; Kiel, Johnathan L; Ryan, Kathy L; Blystone, Robert V; Kalns, John E; Brott, Becky J; Cerna, Cesario Z; Lawrence, William S; Soza, Laura L; Mason, Patrick A

    2006-06-01

    Electromagnetic fields at millimeter wave lengths are being developed for commercial and military use at power levels that can cause temperature increases in the skin. Previous work suggests that sustained exposure to millimeter waves causes greater heating of skin, leading to faster induction of circulatory failure than exposure to environmental heat (EH). We tested this hypothesis in three separate experiments by comparing temperature changes in skin, subcutis, and colon, and the time to reach circulatory collapse (mean arterial blood pressure, 20 mmHg) in male Sprague-Dawley rats exposed to the following conditions that produced similar rates of body core heating within each experiment: (1) EH at 42 degrees C, 35 GHz at 75 mW/cm, or 94 GHz at 75 mW/cm under ketamine and xylazine anesthesia; (2) EH at 43 degrees C, 35 GHz at 90 mW/cm, or 94 GHz at 90 mW/cm under ketamine and xylazine anesthesia; and (3) EH at 42 degrees C, 35 GHz at 90 mW/cm, or 94 GHz at 75 mW/cm under isoflurane anesthesia. In all three experiments, the rate and amount of temperature increase at the subcutis and skin surface differed significantly in the rank order of 94 GHz more than 35 GHz more than EH. The time to reach circulatory collapse was significantly less only for rats exposed to 94 GHz at 90 mW/cm, the group with the greatest rate of skin and subcutis heating of all groups in this study, compared with both the 35 GHz at 90 mW/cm and the EH at 43 degrees C groups. These data indicate that body core heating is the major determinant of induction of hemodynamic collapse, and the influence of heating of the skin and subcutis becomes significant only when a certain threshold rate of heating of these tissues is exceeded.

  6. A new millimeter-wave camera for CMB observations

    Science.gov (United States)

    Aboobaker, Asad Marfani

    Studies of the Cosmic Microwave Background (CMB), driven by advances in detector and telescope technology, have transformed cosmology into a precise science. In this thesis we present a means of observing the CMB with a new class of detectors. Specifically, we present a description of the Column CAMera (CCAM), a prototype instrument for the Atacama Cosmology Telescope (ACT). ACT is designed to measure the CMB anisotropy up to l ~ 10, 000 and perform a galaxy cluster survey using the Sunyaev-Zel'dovich effect. The CCAM instrument tests many of the technologies that will be used in the ACT receiver. We describe aspects of the design of CCAM's cryogenic systems, optics, detector array, and housekeeping system. CCAM observed the sky from Princeton in December, 2005. We measure the noise effective power (NEP) of the CCAM detectors on the sky to be ~ 1.3 × 10 - 17 -- 3 × 10 -17 W/[radical]Hz, comparable to what we expect from ACT. We measure the main beam profile using an astronomical point source using a simple model of the primary aperture intensity distribution. We investigate the sidelobes of the telescope response using the moon as a source and the same beam model as used for the main beam. Last, we examine the pixel-to-pixel covariance of the receiver at various steps during the mapmaking process and find that the cleaned data streams are not highly-correlated. The correlation properties of a point source map agree with the measured beam.

  7. Practical demonstration of spectrally efficient FDM millimeter-wave radio over fiber systems for 5G cellular networking

    Science.gov (United States)

    Mikroulis, Spiros; Xu, Tongyang; Darwazeh, Izzat

    2016-02-01

    This work reports the first demonstration of spectrally efficient frequency division multiplexed (SEFDM) signal transmission based on mm-wave radio over fiber (RoF) technology. Such systems aim to satisfy the beyond 4G (5G) demands of low cost, low energy, millimeter-wave carrier frequencies and high spectral efficiency. The proposed radio over fiber topology, using passive optical network (PON) infrastructure and low-cost multimode fiber (MMF), is analyzed and a proof-of-concept SEFDM radio over 250m OM-1 MMF transmission with a 3m 60GHz wireless link is successfully demonstrated. Different systems are demonstrated, at raw data rates up to 3.7 Gb/s, showing SEFDM spectrum saving up to 40% relative to OFDM.

  8. Millimeter-Wave Microstrip Antenna Array Design and an Adaptive Algorithm for Future 5G Wireless Communication Systems

    Directory of Open Access Journals (Sweden)

    Cheng-Nan Hu

    2016-01-01

    Full Text Available This paper presents a high gain millimeter-wave (mmW low-temperature cofired ceramic (LTCC microstrip antenna array with a compact, simple, and low-profile structure. Incorporating minimum mean square error (MMSE adaptive algorithms with the proposed 64-element microstrip antenna array, the numerical investigation reveals substantial improvements in interference reduction. A prototype is presented with a simple design for mass production. As an experiment, HFSS was used to simulate an antenna with a width of 1 mm and a length of 1.23 mm, resonating at 38 GHz. Two identical mmW LTCC microstrip antenna arrays were built for measurement, and the center element was excited. The results demonstrated a return loss better than 15 dB and a peak gain higher than 6.5 dBi at frequencies of interest, which verified the feasibility of the design concept.

  9. Integrated remotely tunable optical delay line for millimeter-wave beam steering fabricated in an InP generic foundry.

    Science.gov (United States)

    Cao, Z; Tessema, N; Latkowski, S; Zhao, X; Chen, Z; Moskalenko, V; Williams, K A; van der Boom, H P A; Tangdiongga, E; Koonen, A M J

    2015-09-01

    A compact and fabrication-tolerant integrated remotely tunable optical delay line is proposed for millimeter-wave beam steering and is fabricated in an InP generic foundry. The proposed delay line is based on a spectrally cyclic-arrayed waveguide grating feedback loop. Its major features include the tolerant architecture with reduced chip size, and bi-directional operation with simplified remote tuning. Moreover, its cyclic feature guarantees further cascaded operations either for 2D radio beam steering or for high-resolution delay generation. The experimental results show less than 6.5-dB insertion loss of the integrated delay line. Five different delays from 0 to 71.6 ps are generated with less than 0.67-ps delay errors.

  10. Nitrosyl Iodide, Ino: Millimeter-Wave Spectroscopy Guided by AB Initio Quantum Chemical Computation

    Science.gov (United States)

    Bailleux, Stephane; Duflot, Denis; Aiba, Shohei; Ozeki, Hiroyuki

    2015-06-01

    In the series of the nitrosyl halides, XNO (where X = {F, Cl, Br, I}), the millimeter-wave spectrum of INO remains so far unknown. We report our investigation on the first high-resolution rotational spectroscopy of nitrosyl iodide, INO. One of the motivation for this work comes from the growing need in developing a more complete understanding of atmospheric chemistry, especially halogen and nitrogen oxides chemistry that adversely impacts ozone levels. In the family of the nitrogen oxyhalides such as nitrosyl (XNO), nitryl (XNO), nitrite (XONO), and nitrate (XON0_2) halides, those with X = {F, Cl, Br} have been well studied, both theoretically and experimentally. However, relatively little is known about the iodine-containing analogues, although they also are of potential importance in tropospheric chemistry. In 1991, the Fourier-transform IR spectroscopic detection of INO, INO_2 and IONO_2 in the gas phase has been reported The INO molecule was generated by in situ mixing continuously I_2 and NO in a 50-cm long reaction glass tube whose outlet was connected to the absorption cell using a teflon tube. At the time of writing this abstract, 68 μ_a-type transitions (K_a = 0-10), all weak, have been successfully assigned. The hyperfine structures due to both I and N nuclei will also be presented. S.B. and D.D. acknowledge support from the Laboratoire d'Excellence CaPPA (Chemical and Physical Properties of the Atmosphere) through contract ANR-10-LABX-005 of the Programme d'Investissement d'Avenir. I. Barnes, K. H. Becker and J. Starcke, J. Phys. Chem. 1991, 95, 9736-9740.

  11. Path loss analysis in millimeter wave cellular systems for urban mobile communications

    Science.gov (United States)

    Rajagopalan, Ramesh; Hoffman, Mitchell

    2016-09-01

    The proliferation in the number of mobile devices and developments in cellular technology has led to an ever increasing demand for mobile data. The global bandwidth shortage facing wireless carriers today has motivated research for fifth generation (5G) cellular systems. In recent years, millimeter wave (mmW) frequencies between 30 and 300 GHz are being considered as a promising technology for 5G systems. Such systems can offer superior user experience by providing data rates that exceed one Gigabit per second and latencies lower than a millisecond. However, there is little research about cellular mmW propagation in densely populated urban environments. Understanding the radio channel is a primary requirement for optimal design of mmW systems. Radio propagation in mmW systems faces significant challenges due to rapidly varying channel conditions and intermittent connectivity. In this paper, we study the propagation of mmW spectrum in an urban environment. We use a statistical model to simulate an urban environment with diverse building distributions. We perform extensive simulations to analyze the path loss behavior for both line of sight (LOS) and non line of sight (NLOS) conditions for 28 GHZ and 73 GHZ mmW frequencies. We observe that the path loss approximates a logarithmic fit for both LOS and NLOS environments. Our simulations show that the omnidirectional free space path loss is approximately 30 dB higher for mmW systems compared to current 3G PP cellular systems. To address this challenge, we propose using highly directional horn antennas with beam forming for reducing the path loss.

  12. Millimeter-Wave Evolution for 5G Cellular Networks

    Science.gov (United States)

    Sakaguchi, Kei; Tran, Gia Khanh; Shimodaira, Hidekazu; Nanba, Shinobu; Sakurai, Toshiaki; Takinami, Koji; Siaud, Isabelle; Strinati, Emilio Calvanese; Capone, Antonio; Karls, Ingolf; Arefi, Reza; Haustein, Thomas

    Triggered by the explosion of mobile traffic, 5G (5th Generation) cellular network requires evolution to increase the system rate 1000 times higher than the current systems in 10 years. Motivated by this common problem, there are several studies to integrate mm-wave access into current cellular networks as multi-band heterogeneous networks to exploit the ultra-wideband aspect of the mm-wave band. The authors of this paper have proposed comprehensive architecture of cellular networks with mm-wave access, where mm-wave small cell basestations and a conventional macro basestation are connected to Centralized-RAN (C-RAN) to effectively operate the system by enabling power efficient seamless handover as well as centralized resource control including dynamic cell structuring to match the limited coverage of mm-wave access with high traffic user locations via user-plane/control-plane splitting. In this paper, to prove the effectiveness of the proposed 5G cellular networks with mm-wave access, system level simulation is conducted by introducing an expected future traffic model, a measurement based mm-wave propagation model, and a centralized cell association algorithm by exploiting the C-RAN architecture. The numerical results show the effectiveness of the proposed network to realize 1000 times higher system rate than the current network in 10 years which is not achieved by the small cells using commonly considered 3.5 GHz band. Furthermore, the paper also gives latest status of mm-wave devices and regulations to show the feasibility of using mm-wave in the 5G systems.

  13. Automatic detection of hidden threats in the TeraSCREEN passive millimeter-wave imaging subsystem

    Science.gov (United States)

    Madhogaria, Satish; Schikora, Marek

    2015-05-01

    Passive millimeter-wave imaging systems can play a significant role in security applications. Especially, the detection of hidden threats for border security is a growing field. In this paper we propose a novel approach for automatic threat detection using multiple 94 GHz passive millimeter-wave images. Herein, we discuss four steps essential to solving the task: pre-processing, region-of-interest extraction, threat extraction in each frame and, finally, intelligent fusion of the results from all frames. Besides, showing that the proposed method works reliably for the data-set at hand, we also discuss the advantages of using this method in contrast to state-of-the-art methods.

  14. DTU-ESA millimeter-wave validation standard antenna (mm-vast) – performance verification

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Kim, Oleksiy S.; Breinbjerg, Olav

    2015-01-01

    A new multi-frequency Validation Standard (VAST) antenna covering upper microwave (K/Ka) and millimeter wave (Q/V) bands, and thus called mmVAST, was developed in cooperation between DTU and TICRA under contract from the European Space Agency. In this paper, the mechanical and electrical requirem......A new multi-frequency Validation Standard (VAST) antenna covering upper microwave (K/Ka) and millimeter wave (Q/V) bands, and thus called mmVAST, was developed in cooperation between DTU and TICRA under contract from the European Space Agency. In this paper, the mechanical and electrical...... requirements as well as the design and manufacturing of the mm-VAST antenna are briefly presented. The focus is then given to the details of conducted mechanical and electrical tests aimed at verifying the performance of the manufactured antenna and to the obtained measurement results....

  15. Risks of exposure to ionizing and millimeter-wave radiation from airport whole-body scanners.

    Science.gov (United States)

    Moulder, John E

    2012-06-01

    Considerable public concern has been expressed around the world about the radiation risks posed by the backscatter (ionizing radiation) and millimeter-wave (nonionizing radiation) whole-body scanners that have been deployed at many airports. The backscatter and millimeter-wave scanners currently deployed in the U.S. almost certainly pose negligible radiation risks if used as intended, but their safety is difficult-to-impossible to prove using publicly accessible data. The scanners are widely disliked and often feared, which is a problem made worse by what appears to be a veil of secrecy that covers their specifications and dosimetry. Therefore, for these and future similar technologies to gain wide acceptance, more openness is needed, as is independent review and regulation. Publicly accessible, and preferably peer-reviewed evidence is needed that the deployed units (not just the prototypes) meet widely-accepted safety standards. It is also critical that risk-perception issues be handled more competently.

  16. Uniplanar Millimeter-Wave Log-Periodic Dipole Array Antenna Fed by Coplanar Waveguide

    Directory of Open Access Journals (Sweden)

    Guohua Zhai

    2013-01-01

    Full Text Available A uniplanar millimeter-wave broadband printed log-periodic dipole array (PLPDA antenna fed by coplanar waveguide (CPW is introduced. This proposed structure consists of several active dipole elements, feeding lines, parallel coupled line, and the CPW, which are etched on a single metallic layer of the substrate. The parallel coupled line can be optimized to act as a transformer between the CPW and the PLPDA antenna. Meanwhile, this transform performs the task of a balun to achieve a wideband, low cost, low loss, simple directional antenna. The uniplanar nature makes the antenna suitable to be integrated into modern printed communication circuits, especially the monolithic millimeter-wave integrated circuits (MMIC. The antenna has been carefully examined and measured to present the return loss, far-field patterns, and antenna gain.

  17. Noise Performance of Millimeter-wave Silicon Based Mixed Tunneling Avalanche Transit Time(MITATT) Diode

    OpenAIRE

    Aritra Acharyya; Moumita Mukherjee; J. P. Banerjee

    2010-01-01

    A generalized method for small-signal simulation of avalanche noise in Mixed Tunneling Avalanche Transit Time (MITATT) device is presented in this paper where the effect of series resistance is taken into account. The method is applied to a millimeter-wave Double Drift Region (DDR) MITATT device based on Silicon to obtain noise spectral density and noise measure as a function of frequency for different values of series resistance. It is found that noise measure of the dev...

  18. W-Band Technology and Techniques for Analog Millimeter-Wave Photonics

    Science.gov (United States)

    2015-08-19

    this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data...applied field with a rich history [1] that finds utility in numerous areas. An inherent advantage of photonics over electronics is the available...millimeter-wave application is associated with wireless links [5-7], radio astronomy [8], or military systems, the main components that determine the

  19. Fountain Code-Inspired Channel Estimation for Multi-user Millimeter Wave MIMO Systems

    OpenAIRE

    Kokshoorn, Matthew; Chen, He; Li, Yonghui; Vucetic, Branka

    2016-01-01

    This paper develops a novel channel estimation approach for multi-user millimeter wave (mmWave) wireless systems with large antenna arrays. By exploiting the inherent mmWave channel sparsity, we propose a novel simultaneous-estimation with iterative fountain training (SWIFT) framework, in which the average number of channel measurements is adapted to various channel conditions. To this end, the base station (BS) and each user continue to measure the channel with a random subset of transmit/re...

  20. Real time control of satellite tracking station operation for millimeter wave experiments and associated data processing

    Science.gov (United States)

    Kauffman, S. R.; Stutzman, W. L.

    1977-01-01

    Real time control, data collection, and data reduction of an earth-satellite millimeter wave system are discussed. Experiment control and data processing requirements are considered with attention to signal data acquisition, weather data acquisition, support and control functions, task classifications, the fundamental data acquisition procedure, and the computer-experiment interface. The general analysis is applied to a description of the Communications Technology Satellite system and its hardware.

  1. Development and Testing of a Refractory Millimeter-Wave Absorbent Heat Exchanger

    Science.gov (United States)

    Lambot, Thomas; Myrabo, Leik; Murakami, David; Parkin, Kevin

    2014-01-01

    Central to the Millimeter-Wave Thermal Launch System (MTLS) is the millimeter-wave absorbent heat exchanger. We have developed metallic and ceramic variants, with the key challenge being the millimeter-wave absorbent coatings for each. The ceramic heat exchanger came to fruition first, demonstrating for the first time 1800 K peak surface temperatures under illumination by a 110 GHz Gaussian beam. Absorption efficiencies of up to 80 are calculated for mullite heat exchanger tubes and up to 50 are calculated for alumina tubes. These are compared with estimates based on stratified layer and finite element analyses. The problem of how to connect the 1800 K end of the ceramic tubes to a graphite outlet manifold and nozzle is solved by press fitting, or by threading the ends of the ceramic tubes and screwing them into place. The problem of how to connect the ceramic tubes to a metallic or nylon inlet pipe is solved by using soft compliant PTFE and PVC tubes that accommodate thermal deformations of the ceramic tubes during startup and operation. We show the resulting heat exchangers in static tests using argon and helium as propellants.

  2. Sideband-Separating, Millimeter-Wave Heterodyne Receiver

    Science.gov (United States)

    Ward, John S.; Bumble, Bruce; Lee, Karen A.; Kawamura, Jonathan H.; Chattopadhyay, Goutam; Stek, paul; Stek, Paul

    2010-01-01

    Researchers have demonstrated a submillimeter-wave spectrometer that combines extremely broad bandwidth with extremely high sensitivity and spectral resolution to enable future spacecraft to measure the composition of the Earth s troposphere in three dimensions many times per day at spatial resolutions as high as a few kilometers. Microwave limb sounding is a proven remote-sensing technique that measures thermal emission spectra from molecular gases along limb views of the Earth s atmosphere against a cold space background.

  3. A Millimeter-Wave Digital Link for Wireless MRI.

    Science.gov (United States)

    Aggarwal, Kamal; Joshi, Kiran R; Rajavi, Yashar; Taghivand, Mazhareddin; Pauly, John M; Poon, Ada S Y; Scott, Greig

    2017-02-01

    A millimeter (mm) wave radio is presented in this work to support wireless MRI data transmission. High path loss and availability of wide bandwidth make mm-waves an ideal candidate for short range, high data rata communication required for wireless MRI. The proposed system uses a custom designed integrated chip (IC) mm-wave radio with 60 GHz as radio frequency carrier. In this work, we assess performance in a 1.5 T MRI field, with the addition of optical links between the console room and magnet. The system uses ON-OFF keying (OOK) modulation for data transmission and supports data rates from 200 Mb/s to 2.5 Gb/s for distances up-to 65 cm. The presence of highly directional, linearly polarized, on-chip dipole antennas on the mm-wave radio along with the time division multiplexing (TDM) circuitry allows multiple wireless links to be created simultaneously with minimal inter-channel interference. This leads to a highly scalable solution for wireless MRI.

  4. Interferometric millimeter wave and THz wave doppler radar

    Science.gov (United States)

    Liao, Shaolin; Gopalsami, Nachappa; Bakhtiari, Sasan; Raptis, Apostolos C.; Elmer, Thomas

    2015-08-11

    A mixerless high frequency interferometric Doppler radar system and methods has been invented, numerically validated and experimentally tested. A continuous wave source, phase modulator (e.g., a continuously oscillating reference mirror) and intensity detector are utilized. The intensity detector measures the intensity of the combined reflected Doppler signal and the modulated reference beam. Rigorous mathematics formulas have been developed to extract bot amplitude and phase from the measured intensity signal. Software in Matlab has been developed and used to extract such amplitude and phase information from the experimental data. Both amplitude and phase are calculated and the Doppler frequency signature of the object is determined.

  5. Millimeter Wave Attenuation in Moist Air: Laboratory Measurements and Analysis.

    Science.gov (United States)

    1984-03-01

    conversion,. sulphur dioxide. for example, nuciratee with wsar vapor to form sulfuric acid primary, particles in large numbers (am high me 1015 0,3...vapor absorption (mA), which is meet (I) Dielectric loss of water . 25.27, 12. 102-106 evident in chese windows. Excess ieplies that the effect is...31.6S 03(3 is below I Un. a mne or lees invisible cloud exists, Optically rommat fro the line anid responds to the dielectric loss of water

  6. Polarizer design for millimeter-wave plasma diagnostics

    DEFF Research Database (Denmark)

    Leipold, Frank; Salewski, Mirko; Jacobsen, Asger Schou

    2013-01-01

    by birefringent windows, the microwave receivers can be designed to be more compact at lower cost. Sapphire windows (a-cut) as well as grooved high density polyethylene windows can serve this purpose. The sapphire window can be designed such that the calculated transmission of the wave energy is better than 99......Radiation from magnetized plasmas is in general elliptically polarized. In order to convert the elliptical polarization to linear polarization, mirrors with grooved surfaces are currently employed in our collective Thomson scattering diagnostic at ASDEX Upgrade. If these mirrors can be substituted...

  7. Millimeter-Wave Rotational Spectrum of Deuterated Nitric Acid

    Science.gov (United States)

    Butler, Rebecca A. H.; Coplan, Camren; Petkie, Doug; Medvedev, Ivan; De Lucia, Frank C.

    2015-06-01

    Previous studies of the pure rotational spectrum of deuterated nitric acid, DNO3, have focused on the ground and first excited state, νb{9}. This paper focuses on the next lowest energy vibrational states, covering the spectral range from 128-360 GHz. Two of them are unperturbed,νb{7} and νb{8}, and two of them, νb{6} and 2νb{9} are highly perturbed. The unperturbed states are fit separately, while the two perturbed states are fit together using both Coriolis and Fermi interaction terms. Each state is fit to within experimental accuracy. We also extend the assignments and update the rotational constants for νb{9}.

  8. Millimeter-wave and optoelectronic applications of heterostructure integrated circuits

    Science.gov (United States)

    Pavlidis, Dimitris

    1991-01-01

    The properties are reviewed of heterostructure devices for microwave-monolithic-integrated circuits (MMICs) and optoelectronic integrated circuits (OICs). Specific devices examined include lattice-matched and pseudomorphic InAlAs/InGaAs high-electron mobility transistors (HEMTs), mixer/multiplier diodes, and heterojunction bipolar transistors (HBTs) developed with a number of materials. MMICs are reviewed that can be employed for amplification, mixing, and signal generation, and receiver/transmitter applications are set forth for OICs based on GaAs and InP heterostructure designs. HEMTs, HBTs, and junction-FETs can be utilized in combination with PIN, MSM, and laser diodes to develop novel communication systems based on technologies that combine microwave and photonic capabilities.

  9. Diamond Based DDR IMPATTs: Prospects and Potentiality as Millimeter-Wave Source at 94 GHz Atmospheric Window

    Directory of Open Access Journals (Sweden)

    A. Acharyya

    2013-06-01

    Full Text Available Large-signal simulation is carried out in this paper to investigate the prospects and potentiality of Double-Drift Region (DDR Impact Avalanche Transit Time (IMPATT device based on semiconducting type-IIb diamond as millimeter-wave source operating at 94 GHz atmospheric window frequency. Large-signal simulation method developed by the authors and presented in this paper is based on non-sinusoidal voltage excitation. The simulation is carried out to obtain the large-signal characteristics such as RF power output, DC to RF conversion efficiency etc. of DDR diamond IMPATT device designed to operate at 94 GHz. The results show that the device is capable of delivering a peak RF power output of 7.01 W with 10.18% DC to RF conversion efficiency for a bias current density of 6.0×10^8 A m^-2 and voltage modulation of 60% at 94 GHz; whereas for the same voltage modulation 94 GHz DDR Si IMPATT can deliver only 693.82 mW RF power with 8.74 efficiency for the bias current density of 3.4×10^8 A m^-2.

  10. Laboratory microwave, millimeter wave and far-infrared spectra of dimethyl sulfide

    Science.gov (United States)

    Jabri, A.; Van, V.; Nguyen, H. V. L.; Mouhib, H.; Kwabia Tchana, F.; Manceron, L.; Stahl, W.; Kleiner, I.

    2016-05-01

    Context. Dimethyl sulfide, CH3SCH3 (DMS), is a nonrigid, sulfur-containing molecule whose astronomical detection is considered to be possible in the interstellar medium. Very accurate spectroscopic constants were obtained by a laboratory analysis of rotational microwave and millimeter wave spectra, as well as rotation-torsional far-infrared (FIR) spectra, which can be used to predict transition frequencies for a detection in interstellar sources. Aims: This work aims at the experimental study and theoretical analysis of the ground torsional state and ground torsional band ν15 of DMS in a large spectral range for astrophysical use. Methods: The microwave spectrum was measured in the frequency range 2-40 GHz using two Molecular Beam Fourier Transform MicroWave (MB-FTMW) spectrometers in Aachen, Germany. The millimeter spectrum was recorded in the 50-110 GHz range. The FIR spectrum was measured for the first time at high resolution using the FT spectrometer and the newly built cryogenic cell at the French synchrotron SOLEIL. Results: DMS has two equivalent methyl internal rotors with a barrier height of about 730 cm-1. We performed a fit, using the XIAM and BELGI-Cs-2Tops codes, that contained the new measurements and previous transitions reported in the literature for the ground torsional state νt = 0 (including the four torsional species AA, AE, EA and EE) and for the ground torsional band ν15 = 1 ← 0 (including only the AA species). In the microwave region, we analyzed 584 transitions with J ≤ 30 of the ground torsional state νt = 0 and 18 transitions with J ≤ 5 of the first excited torsional state νt = 1. In the FIR range, 578 transitions belonging to the torsional band ν15 = 1 ← 0 with J ≤ 27 were assigned. Totally, 1180 transitions were included in a global fit with 21 accurately determined parameters. These parameters can be used to produce a reliable line-list for an astrophysical detection of DMS. Full Tables B.1 and C.1, and Table E.1 are

  11. On the Performance of Millimeter Wave-based RF-FSO Multi-hop and Mesh Networks

    KAUST Repository

    Makki, Behrooz

    2017-09-22

    This paper studies the performance of multi-hop and mesh networks composed of millimeter wave-based radio frequency (RF) and free-space optical (FSO) links. The results are obtained in cases with and without hybrid automatic repeat request (HARQ). Using the central limit theorem as well as other state-of-the-art approximation schemes, we derive closed-form expressions for the networks’ outage probability and ergodic achievable rates. We also evaluate the effect of various parameters such as power amplifiers efficiency, number of antennas as well as different coherence times of the RF and the FSO links on the system performance. Finally, we determine the minimum number of the transmit antennas in the RF link such that the same rate is supported in the RF- and the FSO-based hops. The results show the efficiency of the RF-FSO setups in different conditions. Moreover, HARQ can effectively improve the outage probability/energy efficiency, and compensate for the effect of hardware impairments in RF-FSO networks. For common parameter settings of the RF-FSO dual-hop networks, outage probability of 10−4 and code rate of 3 nats-per-channel-use, the implementation of HARQ with a maximum of 2 and 3 retransmissions reduces the required power, compared to cases with open-loop communication, by 13 and 17 dB, respectively.

  12. Nondestructive evaluation of cork enclosures using terahertz/millimeter wave spectroscopy and imaging.

    Science.gov (United States)

    Hor, Yew Li; Federici, John F; Wample, Robert L

    2008-01-01

    Natural cork enclosures, due to their cell structure, composition, and low moisture are fairly transparent to terahertz (THz) and millimeter waves enabling nondestructive evaluation of the cork's surface and interior. It is shown that the attenuation coefficient of the defect-free cork can be modeled with a Mie scattering model in the weakly scattering limit. Contrast in the THz images is a result of enhanced scattering of THz radiation by defects or voids as well as variations in the cork cell structure. The presence of voids, defects, and changes in grain structure can be determined with roughly 100-300 microm resolution.

  13. HANET: Millimeter wave based intelligent radio architecture for serving place time capacity issue

    DEFF Research Database (Denmark)

    Lala, Purnima; Sørensen, Troels Bundgaard; Prasad, Ramjee

    2015-01-01

    hotspot conditions aka Place Time Capacity (PTC). In this paper, we explore a disparate way of employing multi-UAV systems by proposing a concept of Hovering Ad-Hoc Network (HANET) distinctively to solve PTC congestion using millimeter wave communication. We present a suitable architecture based...... on airborne HANET members as load balancing assistance to the primary network to offload user traffic to the nearby base station. The paper also presents a conceptual physical design of a HANET member to further endorse the proposed architecture....

  14. A Practical Millimeter-Wave Holographic Imaging System with Tunable IF Attenuator

    Science.gov (United States)

    Zhu, Yu-Kun; Yang, Ming-Hui; Wu, Liang; Sun, Yun; Sun, Xiao-Wei

    2017-10-01

    A practical millimeter-wave (mmw) holographic imaging system with tunable intermediate frequency (IF) attenuator has been developed. It can be used for the detection of concealed weapons at security checkpoints, especially the airport. The system is utilized to scan the passenger and detect the weapons hidden in the clothes. To reconstruct the three dimensions (3-D) image, a holographic mmw imaging algorithm based on aperture synthesis and back scattering is presented. The system is active and works at 28-33 GHz. Tunable IF attenuator is applied to compensate the intensity and phase differences between multi-channels and multi-frequencies.

  15. Telecommunication service markets through the year 2000 in relation to millimeter wave satellite systems

    Science.gov (United States)

    Stevenson, S. M.

    1979-01-01

    NASA is currently conducting a series of millimeter wave satellite system market studies to develop 30/20 GHz satellite system concepts that have commercial potential. Four contractual efforts were undertaken: two parallel and independent system studies and two parallel and independent market studies. The marketing efforts are focused on forecasting the total domestic demand for long haul telecommunications services for the 1980-2000 period. Work completed to date and reported in this paper include projections of: geographical distribution of traffic; traffic volume as a function of urban area size; and user identification and forecasted demand.

  16. Simultaneous generation of 40, 80 and 120 GHz optical millimeter-wave from one Mach-Zehnder modulator and demonstration of millimeter-wave transmission and down-conversion

    Science.gov (United States)

    Zhou, Wen; Qin, Chaoyi

    2017-09-01

    We demonstrate multi-frequency QPSK millimeter-wave (mm-wave) vector signal generation enabled by MZM-based optical carrier suppression (OCS) modulation and in-phase/quadrature (I/Q) modulation. We numerically simulate the generation of 40-, 80- and 120-GHz vector signal. Here, the three different signals carry the same QPSK modulation information. We also experimentally realize 11Gbaud/s QPSK vector signal transmission over 20 km fiber, and the generation of the vector signals at 40-GHz, 80-GHz and 120-GHz. The experimental results show that the bit-error-rate (BER) for all the three different signals can reach the forward-error-correction (FEC) threshold of 3.8×10-3. The advantage of the proposed system is that provide high-speed, high-bandwidth and high-capacity seamless access of TDM and wireless network. These features indicate the important application prospect in wireless access networks for WiMax, Wi-Fi and 5G/LTE.

  17. Performance Evaluation of 5G Millimeter-Wave Cellular Access Networks Using a Capacity-Based Network Deployment Tool

    Directory of Open Access Journals (Sweden)

    Michel Matalatala

    2017-01-01

    Full Text Available The next fifth generation (5G of wireless communication networks comes with a set of new features to satisfy the demand of data-intensive applications: millimeter-wave frequencies, massive antenna arrays, beamforming, dense cells, and so forth. In this paper, we investigate the use of beamforming techniques through various architectures and evaluate the performance of 5G wireless access networks, using a capacity-based network deployment tool. This tool is proposed and applied to a realistic area in Ghent, Belgium, to simulate realistic 5G networks that respond to the instantaneous bit rate required by the active users. The results show that, with beamforming, 5G networks require almost 15% more base stations and 4 times less power to provide more capacity to the users and the same coverage performances, in comparison with the 4G reference network. Moreover, they are 3 times more energy efficient than the 4G network and the hybrid beamforming architecture appears to be a suitable architecture for beamforming to be considered when designing a 5G cellular network.

  18. Performance Analysis of Millimeter-Wave Multi-hop Machine-to-Machine Networks Based on Hop Distance Statistics.

    Science.gov (United States)

    Jung, Haejoon; Lee, In-Ho

    2018-01-12

    As an intrinsic part of the Internet of Things (IoT) ecosystem, machine-to-machine (M2M) communications are expected to provide ubiquitous connectivity between machines. Millimeter-wave (mmWave) communication is another promising technology for the future communication systems to alleviate the pressure of scarce spectrum resources. For this reason, in this paper, we consider multi-hop M2M communications, where a machine-type communication (MTC) device with the limited transmit power relays to help other devices using mmWave. To be specific, we focus on hop distance statistics and their impacts on system performances in multi-hop wireless networks (MWNs) with directional antenna arrays in mmWave for M2M communications. Different from microwave systems, in mmWave communications, wireless channel suffers from blockage by obstacles that heavily attenuate line-of-sight signals, which may result in limited per-hop progress in MWNs. We consider two routing strategies aiming at different types of applications and derive the probability distributions of their hop distances. Moreover, we provide their baseline statistics assuming the blockage-free scenario to quantify the impact of blockages. Based on the hop distance analysis, we propose a method to estimate the end-to-end performances (e.g., outage probability, hop count, and transmit energy) of the mmWave MWNs, which provides important insights into mmWave MWN design without time-consuming and repetitive end-to-end simulation.

  19. [EEG changes and stress reactions in rat induced by millimeter wave].

    Science.gov (United States)

    Xie, Taorong; Pei, Jian; Li, Fen; Huang, Xin; Chen, Shude; Qiao, Dengjiang

    2011-02-01

    The present paper is aimed to study the processes of stress reaction and their judgment bases in rat induced by 35 GHz millimeter wave quantitatively. The relative change in the average energy of each EEG frequency band decomposed by wavelet analysis was calculated for extracting the stress indicator for the purpose. The rat would experience quiet period, guarding period, deadlock period and prostrating period in sequence. The judgment bases of different stress periods in rat induced by millimeter wave were obtained by analyzing the skin temperature, skin injury and changes of blood biochemical indexes during each stress period. The stress period changed from quiet period to guarding period when the skin temperature of irradiated area reached the thermal pain threshold. It was from guarding period to deadlock period when the skin had gotten serious injury. Then the rat reaction sensitivity decreased, and injury of its visceral organs occurred. The rat got to prostrating period when the sustained irradiation caused the rat's visceral organs to get more serious injury. The further sustained irradiation finally induced death of the rat.

  20. Use of Gaussian Beam Tracing in the Design of Millimeter-Wave Diagnostics on ITER

    Science.gov (United States)

    Joo, Heeseok; Bitter, Manfred; Tobias, Ben; Park, Hyeon; Zolfaghari, Ali

    2016-10-01

    When the wavelength of the radiation being studied is comparable to the size optical components, the diffraction effect cannot be ignored. Gaussian beam tracing (GBT) can be used by treating the propagation of the light as a beam with certain size rather than a ray used in geometrical optics when analyzing the optics of millimeter-wave diagnostics. Gaussian optics is an effective way to represent diffraction effect because of its ability to show the beam size and the intensity that could be altered from diffraction. GBT has been used in two millimeter-wave diagnostics suited to ITER geometry. The first is in a design of a Gaussian telescope for correction of transmission line misalignment in the ITER LFS reflectometer due to motion of the vessel during heating to operating temperature from room temperature. The second is a new concept of using spherical mirrors for electron cyclotron emission imaging (ECEI) and assessing its promise of a more realistic method of ECEI in ITER than previous idea of using a cylindrical mirror that requires large access ports that can be exposed to intense neutron radiation. The spherical mirror promises a smaller aperture on the first wall of ITER. The simulation of GBT of the two applications are analyzed and discussed. This work is supported by US DOE Contract No. DE-AC02-09CH11466.

  1. Recollections of Tucson Operations The Millimeter-Wave Observatory of the National Radio Astronomy Observatory

    CERN Document Server

    Gordon, M A

    2005-01-01

    This book is a personal account of the evolution of millimeter-wave astronomy at the National Radio Astronomy Observatory. It begins with the construction of the hugely successful, but flawed, 36 ft radio telescope on Kitt Peak, Arizona, and continues through the funding of its ultimate successor, the Atacama Large Millimeter-wave Array (ALMA), being constructed on a 5.000 m (16.500 ft) site in northern Chile. The book describes the behind-the-scene activities of the NRAO Tucson staff. These include the identification and solution of technical problems, the scheduling and support of visiting astronomers, and the preparations and the politics of the proposal to replace the 36 ft telescope with a 25 m telescope on Mauna Kea, Hawaii. The book also describes the installation of a new 12 m surface and the involvement of the Tucson staff in the ALMA project. Finally, it describes events leading to the closing of the 36 ft telescope and, eventually, of the NRAO offices in Tucson.

  2. Photonic generation of frequency quadrupling signal for millimeter-wave communication utilizing three parallel Mach-Zehnder modulators

    Science.gov (United States)

    Mu, Hang; Liu, Yanjun; Wang, Daobin; Lei, Jingli; Hou, Shanglin

    2017-02-01

    In this work, we propose a new scheme of generating high quality frequency quadrupling signal for millimeter-wave wireless communication system. The frequency quadrupling scheme is achieved by using three parallel Mach-Zehnder modulators (MZMs) and an optical phase shifter. The first two MZMs are driven by the RF signals to operate at the maximum transmission point. The third MZM is operated with no RF signal and an extra π-phase difference is introduced for it by the optical phase shifter. The advantage of the proposed scheme is that the optical carrier and the fourth optical sideband can be suppressed simultaneously. The performance of proposed scheme is investigated theoretically and evaluated by simulations. Numerical results show that the radio frequency spurious suppression ratio (RFSSR) higher than 44.18 dB and the optical sideband suppression ratio (OSSR) higher than 21 dB can be obtained without optical filter when the extinction ratio (ER) of the MZM is 30 dB. The impact of the non-ideal RF driven voltage and phase difference of RF driven signal applied to the first two sub-MZMs on OSSR and RFSSR is also discussed and analyzed.

  3. Effect of random surface inhomogeneities on spectral properties of dielectric-disk microresonators: theory and modeling at millimeter wave range.

    Science.gov (United States)

    Ganapolskii, E M; Eremenko, Z E; Tarasov, Yu V

    2009-04-01

    The influence of random axially homogeneous surface roughness on spectral properties of dielectric resonators of circular disk form is studied both theoretically and experimentally. To solve the equations governing the dynamics of electromagnetic fields, the method of eigenmode separation is applied previously developed with reference to inhomogeneous systems subject to arbitrary external static potential. We prove theoretically that it is the gradient mechanism of wave-surface scattering that is highly responsible for nondissipative loss in the resonator. The influence of side-boundary inhomogeneities on the resonator spectrum is shown to be described in terms of effective renormalization of mode wave numbers jointly with azimuth indices in the characteristic equation. To study experimentally the effect of inhomogeneities on the resonator spectrum, the method of modeling in the millimeter wave range is applied. As a model object, we use a dielectric disk resonator (DDR) fitted with external inhomogeneities randomly arranged at its side boundary. Experimental results show good agreement with theoretical predictions as regards the predominance of the gradient scattering mechanism. It is shown theoretically and confirmed in the experiment that TM oscillations in the DDR are less affected by surface inhomogeneities than TE oscillations with the same azimuth indices. The DDR model chosen for our study as well as characteristic equations obtained thereupon enable one to calculate both the eigenfrequencies and the Q factors of resonance spectral lines to fairly good accuracy. The results of calculations agree well with obtained experimental data.

  4. Characterization of nanostructure ferrite material on gallium nitride on SiC substrate for millimeter wave integrated circuit

    Directory of Open Access Journals (Sweden)

    Brian O’Keefe

    2017-05-01

    Full Text Available In this paper, for the first time, the characterization of spin-casted thick Barium nano-hexaferrite film on GaN-on-SiC substrate over a broad frequency range of 30-110 GHz is presented. Real and imaginary parts of both permittivity and permeability of the ferrite/polymer film are computed from transmittance data obtained by using a free space quasi-optical millimeter wave spectrometer. The spin-casted composite film shows strong resonance in the Q band, and mixing the powder with polymer slightly shifts the resonance frequency lower compared to pure powder. The high temperature compatibility of GaN substrate enables us to run burn-out tests at temperatures up to 900°C. Significant shortening phenomenon of resonance linewidth after heat treatment was found. Linewidth is reduced from 2.8 kOe to 1.7 kOe. Experiment results show that the aforementioned film is a good candidate in applications of non-reciprocal ferrite devices like isolators, phase shifters, and circulators.

  5. The millimeter wave spectrum of methyl cyanate: a laboratory study and astronomical search in space ⋆,⋆⋆

    Science.gov (United States)

    Kolesniková, L.; Alonso, J. L.; Bermúdez, C.; Alonso, E. R.; Tercero, B.; Cernicharo, J.; Guillemin, J.-C.

    2016-01-01

    Aims The recent discovery of methyl isocyanate (CH3NCO) in Sgr B2(N) and Orion KL makes methyl cyanate (CH3OCN) a potential molecule in the interstellar medium. The aim of this work is to fulfill the first requirement for its unequivocal identification in space, i.e. the availability of transition frequencies with high accuracy. Methods The room-temperature rotational spectrum of methyl cyanate was recorded in the millimeter wave domain from 130 to 350 GHz. All rotational transitions revealed A-E splitting owing to methyl internal rotation and were globally analyzed using the ERHAM program. Results The data set for the ground torsional state of methyl cyanate exceeds 700 transitions within J″ = 10 – 35 and Ka″=0−13 and newly derived spectroscopic constants reproduce the spectrum close to the experimental uncertainty. Spectral features of methyl cyanate were then searched for in Orion KL, Sgr B2(N), B1-b, and TMC-1 molecular clouds. Upper limits to the column density of methyl cyanate are provided. PMID:27721514

  6. Assessment of risks of EMI for personal medical electronic devices (PMEDs) from emissions of millimeter-wave security screening systems

    Science.gov (United States)

    Witters, Donald; Bassen, Howard; Guag, Joshua; Addissie, Bisrat; LaSorte, Nickolas; Rafai, Hazem

    2013-06-01

    This paper describes research and testing of a representative group of high priority body worn and implantable personal medical electronic devices (PMEDs) for exposure to millimeter wave (MMW) advanced imaging technology (AIT) security systems used at airports. The sample PMEDs included in this study were implantable cardiac pacemakers, ICDs, neurostimulators and insulin pumps. These PMEDs are designed and tested for susceptibility to electromagnetic interference (EMI) under the present standards for medical device electromagnetic compatibility (EMC). However, the present standards for medical equipment do not address exposure to the much higher frequency fields that are emitted by MMW security systems. Initial AIT emissions measurements were performed to assess the PMED and passenger exposures. Testing protocols were developed and testing methods were tailored to the type of PMED. In addition, a novel exposure simulation system was developed to allow controlled EMC testing without the need of the MMW AIT system. Methodology, test results, and analysis are presented, along with an assessment of the human exposure and risks for PMED users. The results on this study reveal no effects on the medical devices from the exposure to the MMW security system. Furthermore, the human exposure measurements and analysis showed levels well below applicable standard, and the risks for PMED users and others we assessed to be very low. These findings apply to the types of PMEDs used in the study though these findings might suggest that the risks for other, similar PMEDs would likely be similar.

  7. Enhancing the Bandwidth Utilization in the Millimeter Wave Band and to Modernize the Digital Signal Processing Laboratory at the California State University, Bakersfield

    Science.gov (United States)

    2016-03-16

    Multidisciplinary adaptive wireless communication systems: Reconfigurable MEMS integrated antennas & coding/decoding structures,” in Proc. IEEE Topical...state of the art on millimeter-wave communications by developing new transmission mechanism, network models, and channel characterizations. The views...P.O. Box 12211 Research Triangle Park, NC 27709-2211 Millimeter-wave communications , signal processing, communications , hardware impairments

  8. Analysis of Rectangular Folded-Waveguide Millimeter-Wave Slow-wave Structures using Conformal Transformations

    Science.gov (United States)

    Sumathy, M.; Vinoy, K. J.; Datta, S. K.

    2009-03-01

    An analysis of rectangular folded-waveguide slow-wave structure was developed using conformal mapping technique through Schwarz’s polygon transformation and closed form expressions for the lumped capacitance and inductance per period of the slow-wave structure were derived in terms of the physical dimensions of the structure, incorporating the effects of the beam hole in the lumped parameters. The lumped parameters were subsequently interpreted for obtaining the dispersion and interaction impedance characteristics of the structure. The analysis was benchmarked for two typical millimeter-wave structures, one operating in Ka-band and the other operating in Q-band, against measurement and 3D electromagnetic modeling using MAFIA.

  9. Millimeter-Wave Chemical Sensor Using Substrate-Integrated-Waveguide Cavity.

    Science.gov (United States)

    Memon, Muhammad Usman; Lim, Sungjoon

    2016-10-31

    This research proposes a substrate-integrated waveguide (SIW) cavity sensor to detect several chemicals using the millimeter-wave frequency range. The frequency response of the presented SIW sensor is switched by filling a very small quantity of chemical inside of the fluidic channel, which also causes a difference in the effective permittivity. The fluidic channel on this structure is either empty or filled with a chemical; when it is empty the structure resonates at 17.08 GHz. There is always a different resonant frequency when any chemical is injected into the fluidic channel. The maximum amount of chemical after injection is held in the center of the SIW structure, which has the maximum magnitude of the electric field distribution. Thus, the objective of sensing chemicals in this research is achieved by perturbing the electric fields of the SIW structure.

  10. Cylindrical Three-Dimensional Millimeter-Wave Imaging via Compressive Sensing

    Directory of Open Access Journals (Sweden)

    Guoqiang Zhao

    2015-01-01

    Full Text Available Millimeter-wave (MMW imaging techniques have been used for the detection of concealed weapons and contraband carried by personnel. However, the future application of the new technology may be limited by its large number of antennas. In order to reduce the complexity of the hardware, a novel MMW imaging method based on compressive sensing (CS is proposed in this paper. The MMW images can be reconstructed from the significantly undersampled backscattered data via the CS approach. Thus the number of antennas and the cost of system can be further reduced than those based on the traditional imaging methods that obey the Nyquist sampling theorem. The effectiveness of the proposed method is validated by numerical simulations as well as by real measured data of objects.

  11. An Overview of Multigigabit Wireless through Millimeter Wave Technology: Potentials and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Chong Chia-Chin

    2007-01-01

    Full Text Available This paper presents an overview of 60 GHz technology and its potentials to provide next generation multigigabit wireless communications systems. We begin by reviewing the state-of-art of the 60 GHz radio. Then, the current status of worldwide regulatory efforts and standardization activities for 60 GHz band is summarized. As a result of the worldwide unlicensed 60 GHz band allocation, a number of key applications can be identified using millimeter-wave technology. Despite of its huge potentials to achieve multigigabit wireless communications, 60 GHz radio presents a series of technical challenges that needs to be resolved before its full deployment. Specifically, we will focus on the link budget analysis from the 60 GHz radio propagation standpoint and highlight the roles of antennas in establishing a reliable 60 GHz radio.

  12. An Overview of Multigigabit Wireless through Millimeter Wave Technology: Potentials and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Chia-Chin Chong

    2006-12-01

    Full Text Available This paper presents an overview of 60 GHz technology and its potentials to provide next generation multigigabit wireless communications systems. We begin by reviewing the state-of-art of the 60 GHz radio. Then, the current status of worldwide regulatory efforts and standardization activities for 60 GHz band is summarized. As a result of the worldwide unlicensed 60 GHz band allocation, a number of key applications can be identified using millimeter-wave technology. Despite of its huge potentials to achieve multigigabit wireless communications, 60 GHz radio presents a series of technical challenges that needs to be resolved before its full deployment. Specifically, we will focus on the link budget analysis from the 60 GHz radio propagation standpoint and highlight the roles of antennas in establishing a reliable 60 GHz radio.

  13. The involvement of cutaneous receptors in the biological effects of electromagnetic millimeter waves

    Directory of Open Access Journals (Sweden)

    Anton Emil

    2014-01-01

    Full Text Available The involvement of peripheral nerve terminations in the mechanisms of action of electromagnetic millimeter waves (mmW was assessed. It is currently thought that mmW could be used in noninvasive complementary therapy because of their analgesic effect. However, the mechanisms of their antinociceptive effect and non-ionizing radiation are the subjects of controversy. The mechanisms of interaction of mmW and the cutaneous tissue have not been elucidated. We observed mast cell degranulation at the place of mmW action, a decrease of chronaxie and Turck reflex time, an increase in the number of afferent impulses after sciatic nerve at stimulation, as well as an increase electrocardiogram R-R interval of isolated frog heart after application of mmW. Based on these investigations, we propose that electromagnetic waves of millimeter length modify, through indirect mechanisms, the excitability and reactivity of peripheral nerve terminations.

  14. DTU-ESA millimeter-wave validation standard antenna – requirements and design

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Kim, Oleksiy S.; Breinbjerg, Olav

    2014-01-01

    Inter-comparisons and validations of antenna measurement ranges are useful tools allowing the detection of various problems in the measurement procedures, thus leading to improvements of the measurement accuracy and facilitating better understanding of the measurement techniques. The maximum value...... from a validation campaign is achieved when a dedicated Validation Standard (VAST) antenna specifically designed for this purpose is available. The driving requirements to VAST antennas are their mechanical stability with respect to any orientation of the antenna in the gravity field and thermal...... stability over a given operational temperature range. In addition, VAST antennas must possess electrical characteristics that are typical for satellite antennas and challenging to measure. A multi-band millimeter-wave VAST (mm-VAST) antenna for the K/Ka-bands and Q/V bands is currently under development...

  15. The Application of Nonlinear Spectral Subtraction Method on Millimeter Wave Conducted Speech Enhancement

    Directory of Open Access Journals (Sweden)

    Sheng Li

    2010-01-01

    Full Text Available A nonlinear multiband spectral subtraction method is investigated in this study to reduce the colored electronic noise in millimeter wave (MMW radar conducted speech. Because the over-subtraction factor of each Bark frequency band can be adaptively adjusted, the nonuniform effects of colored noise in the spectrum of the MMW radar speech can be taken into account in the enhancement process. Both the results of the time-frequency distribution analysis and perceptual evaluation test suggest that a better whole-frequency noise reduction effect is obtained, and the perceptually annoying musical noise was efficiently reduced, with little distortion to speech information as compared to the other standard speech enhancement algorithm.

  16. A survey of the millimeter-wave spectrum of Sagittarius B2

    Science.gov (United States)

    Cummins, S. E.; Thaddeus, P.; Linke, R. A.

    1986-01-01

    More than 60 percent of the millimeter wave spectrum between 70 and 150 GHz of the giant Sgr B2 molecular cloud was surveyed with the Bell Laboratories 7 m telescope at a spectral resolution of 1 MHz. The observations and instrumentation are described, including beam efficiency and beamwidth as functions of frequency, frequency coverage, and rms noise. The catalog used to identify the 457 lines found is summarized, and the analysis of the data to determine column densities and rotational temperatures is discussed. The range of rotational temperatures obtained and their relation to the kinetic temperature, and their implications for the hydrogen density, are considered. More than 300 lines are transitions of 21 molecules, and the results for these are analyzed, giving excitation diagrams for most of them. A partly successful attempt is made to use ratios of the calculated abundances to predict abundances of as yet undetected species. Finally, the spectra for the entire survey are presented.

  17. Experimental Research on Passive Millimeter Wave Radiometric Stealth Technology of Metal Objects

    Science.gov (United States)

    Zhang, Guangfeng; Lou, Guowei; Li, Xingguo

    2012-12-01

    Working all day and all weather, a passive millimeter wave radiometer (PMMW) can be widely used in civil and military affairs. It can get some specific information about the material characteristics different from radar and infrared detectors. On basis of the radiometric operating range equation, the radiation cross section and stealth effect of metal objects are presented for the PMMW near-sensing application. The measurement experiments of metal solid models adopts 3 mm band Dicke radiometer with the outdoor calibration system. The sky temperature and other different surface metal objects are also measured as the contrastive experiments. The results show the radiometric temperature contrasts of solid models have remarkable difference in the bare and coated conditions, and the radiometric operating range can decrease to 60.8 %. In addition, the PMMW stealth methods through different surface treatment respectively reduce the radiometric antenna temperature contrast in some degree.

  18. Chirped-Pulse millimeter-Wave spectroscopy for dynamics and kinetics studies of pyrolysis reactions.

    Science.gov (United States)

    Prozument, Kirill; Barratt Park, G; Shaver, Rachel G; Vasiliou, AnGayle K; Oldham, James M; David, Donald E; Muenter, John S; Stanton, John F; Suits, Arthur G; Barney Ellison, G; Field, Robert W

    2014-08-14

    A Chirped-Pulse millimeter-Wave (CPmmW) spectrometer is applied to the study of chemical reaction products that result from pyrolysis in a Chen nozzle heated to 1000-1800 K. Millimeter-wave rotational spectroscopy unambiguously determines, for each polar reaction product, the species, the conformers, relative concentrations, conversion percentage from precursor to each product, and, in some cases, vibrational state population distributions. A chirped-pulse spectrometer can, within the frequency range of a single chirp, sample spectral regions of up to ∼10 GHz and simultaneously detect many reaction products. Here we introduce a modification to the CPmmW technique in which multiple chirps of different spectral content are applied to a molecular beam pulse that contains the pyrolysis reaction products. This technique allows for controlled allocation of its sensitivity to specific molecular transitions and effectively doubles the bandwidth of the spectrometer. As an example, the pyrolysis reaction of ethyl nitrite, CH3CH2ONO, is studied, and CH3CHO, H2CO, and HNO products are simultaneously observed and quantified, exploiting the multi-chirp CPmmW technique. Rotational and vibrational temperatures of some product molecules are determined. Subsequent to supersonic expansion from the heated nozzle, acetaldehyde molecules display a rotational temperature of 4 ± 1 K. Vibrational temperatures are found to be controlled by the collisional cooling in the expansion, and to be both species- and vibrational mode-dependent. Rotational transitions of vibrationally excited formaldehyde in levels ν4, 2ν4, 3ν4, ν2, ν3, and ν6 are observed and effective vibrational temperatures for modes 2, 3, 4, and 6 are determined and discussed.

  19. Ultra-Wideband Millimeter-Wave Dielectric Characteristics of Freshly-Excised Normal and Malignant Human Skin Tissues.

    Science.gov (United States)

    Mirbeik-Sabzevari, Amir; Ashinoff, Robin; Tavassolian, Negar

    2017-09-06

    Millimeter waves have recently gained attention for the evaluation of skin lesions and the detection of skin tumors. Such evaluations heavily rely on the dielectric contrasts existing between normal and malignant skin tissues at millimeter-wave frequencies. However, current studies on the dielectric properties of normal and diseased skin tissues at these frequencies are limited and inconsistent. In this work, a comprehensive dielectric spectroscopy study is conducted for the first time to characterize the ultra-wideband dielectric properties of freshly-excised normal and malignant skin tissues obtained from skin cancer patients having undergone Mohs micrographic surgeries at Hackensack University Medical Center. Measurements are conducted using a precision slim-form open-ended coaxial probe in conjunction with a millimeter-wave vector network analyzer over the frequency range of 0.5-50 GHz. A one-pole Cole-Cole model is fitted to the complex permittivity dataset of each sample. Statistically considerable contrasts are observed between the dielectric properties of malignant and normal skin tissues over the ultra-wideband millimeter-wave frequency range considered.

  20. Simultaneous Generations of Independent Millimeter Wave and 10 Gbit/s Wired Signal by Single Electrode Modulator in TDM-PON Network

    Science.gov (United States)

    Niazi, Shahab Ahmad; Zhang, Xiaoguang; Xi, Lixia; Idress, Muhammad

    2013-03-01

    We propose and present a cost effective and simple technique of simultaneous generation and propagation of millimeter wave with recently standardized 10 giga bit passive optical network (GPON) by mixing of 2.5 Gbit/s, 30 GHz radio wave with 10 Gbit/s based band signal and then modulated by single Mach Zehnder modulator (MZM). In this scheme, we have applied 1490 nm for downstream, 1310 nm for upstream transmission and ON OFF keying (OOK) modulation format to make it fully align with existing standards and infrastructure. Simulation results show error free transmission performance with negligible power penalty over 25 km bidirectional fiber. We also highlight the principles and discuss the main technical challenges for commercial realization of 60 GHz spectrum.

  1. 2D Unitary ESPRIT Based Super-Resolution Channel Estimation for Millimeter-Wave Massive MIMO with Hybrid Precoding

    KAUST Repository

    Liao, Anwen

    2017-11-01

    Millimeter-wave (mmWave) massive multiple-input multiple-output (MIMO) with hybrid precoding is a promising technique for the future 5G wireless communications. Due to a large number of antennas but a much smaller number of radio frequency (RF) chains, estimating the high-dimensional mmWave massive MIMO channel will bring the large pilot overhead. To overcome this challenge, this paper proposes a super-resolution channel estimation scheme based on two-dimensional (2D) unitary ESPRIT algorithm. By exploiting the angular sparsity of mmWave channels, the continuously distributed angle of arrivals/departures (AoAs/AoDs) can be jointly estimated with high accuracy. Specifically, by designing the uplink training signals at both base station (BS) and mobile station (MS), we first use low pilot overhead to estimate a low-dimensional effective channel, which has the same shift-invariance of array response as the high-dimensional mmWave MIMO channel to be estimated. From the low-dimensional effective channel, the superresolution estimates of AoAs and AoDs can be jointly obtained by exploiting the 2D unitary ESPRIT channel estimation algorithm. Furthermore, the associated path gains can be acquired based on the least squares (LS) criterion. Finally, we can reconstruct the high-dimensional mmWave MIMO channel according to the obtained AoAs, AoDs, and path gains. Simulation results have confirmed that the proposed scheme is superior to conventional schemes with a much lower pilot overhead.

  2. Over-the-air Radiated Testing of Millimeter-Wave Beam-steerable Devices in a Cost-Effective Measurement Setup

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Rumney, Moray

    2018-01-01

    With the severe spectrum congestion of sub-6GHz cellular systems, large-scale antenna systems in the millimeter-wave (mmWave) bands can potentially meet the high data rate envisioned for fifth generation (5G) communications. Performance evaluation of antenna systems is an essential step...... in the product design and development stage. However, conventional cable conducted test methods are not applicable for mmWave devices. There is a strong need for over-the-air (OTA) radiated methods, where mmWave device performance can be evaluated in a reliable, repeatable, and feasible way in laboratory...... conditions. In this article, radiated testing methods are reviewed, with a focus on their principle and applicability for beam steerable mmWave devices. To explore the spatial sparsity of mmWave channel profiles, a cost-effective simplified 3D sectored multi-probe anechoic chamber (MPAC) system with an OTA...

  3. Electromagnetic design of an all-diffractive millimeter-wave imaging system.

    Science.gov (United States)

    Chen, Caihua; Shi, Shouyan; Prather, Dennis W

    2004-04-20

    We present the design and electromagnetic analysis of an all-diffractive millimeter-wave imaging system having a field of view of +/- 15 degrees. This system consists of two 16-level diffractive lenses, with the stop in contact with the first lens. By considering the Seidel aberrations for a diffractive lens and applying the corresponding stop shift formula, we established the expressions of third-order wave aberrations for this system. By setting all primary Seidel aberrations to zero and solving the corresponding system of equations, we obtained two sets of solutions for this two-element all-diffractive system, which totally compensate for all Seidel aberrations. To assess image system performance, we apply the finite-difference time-domain technique and a vector plane-wave spectrum method, in combination, to validate the performance of the system. To reduce the computational cost and thereby enable the complete electromagnetic analysis of the system, a four-step analysis procedure has been developed and applied as an electromagnetic system model.

  4. Millimeter-wave GaAs stepped-impedance hairpin resonator filters using surface micromachining

    Science.gov (United States)

    Cho, Ju-Hyun; Yun, Tae-Soon; Baek, Tae-Jong; Ko, Back-Seok; Shin, Dong-Hoon; Lee, Jong-Chul

    2005-05-01

    In this paper, microstrip stepped-impedance hairpin resonator (SIR) low-pass filter (LPF) and slow-wave band-pass filter (BPF) using dielectric supported air-gapped microstrip line (DAML) of surface micromachining on GaAs substrate are proposed. The DAML structure, which is a new low-loss micromachining transmission line, is useful for the integration of MEMS and/or MMIC components. Design parameters for the proposed SIR low-pass and slow-wave band-pass filters are derived based on stepped-impedance theory. The proposed slow-wave BPF is designed to produce a passband of 10% at the fundamental frequency of 60 GHz. and a new SIR LPF with aperture and IDC (inter-digital capacitor) is designed for 3-dB cutoff frequency of 33 GHz. The measurement results of the BPF filter and LPF filter agree well with simulation results. These filters are useful for many millimeter-wave system applications.

  5. Metamaterial CRLH Antennas on Silicon Substrate for Millimeter-Wave Integrated Circuits

    Directory of Open Access Journals (Sweden)

    Gheorghe Ioan Sajin

    2012-01-01

    Full Text Available The paper presents two composite right/left-handed (CRLH coplanar waveguide (CPW zeroth-order resonant (ZOR antennas which were designed, processed, and electrically characterized for applications in the millimetric wave frequency range. Two CRLH antennas were developed for f=27 GHz and f=38.5, GHz, respectively. The CRLH antenna on f=27 GHz shows a return loss of RL<−18.78 dB at f=26.88 GHz. The −3 dB radiation characteristic beamwidth was approximately 37° and the gain was Gi=2.82 dBi. The CRLH antenna on f=38.5 GHz has a return loss of RL<−38.5 dB at f=38.82 GHz and the −3 dB radiation characteristic beamwidth of approximately 17°. The gains were Gi=1.08 dBi at f=38 GHz and Gi=1.2 dBi at f=38.6 GHz. The maximum measured gain was Gi=1.75 dBi at f=38.2 GHz. It is, upon the authors' knowledge, the first report of millimeter wave CRLH antennas on silicon substrate in CPW technique for use in mm-wave monolithic integrated circuit.

  6. Realization of a video-rate distributed aperture millimeter-wave imaging system using optical upconversion

    Science.gov (United States)

    Schuetz, Christopher; Martin, Richard; Dillon, Thomas; Yao, Peng; Mackrides, Daniel; Harrity, Charles; Zablocki, Alicia; Shreve, Kevin; Bonnett, James; Curt, Petersen; Prather, Dennis

    2013-05-01

    Passive imaging using millimeter waves (mmWs) has many advantages and applications in the defense and security markets. All terrestrial bodies emit mmW radiation and these wavelengths are able to penetrate smoke, fog/clouds/marine layers, and even clothing. One primary obstacle to imaging in this spectrum is that longer wavelengths require larger apertures to achieve the resolutions desired for many applications. Accordingly, lens-based focal plane systems and scanning systems tend to require large aperture optics, which increase the achievable size and weight of such systems to beyond what can be supported by many applications. To overcome this limitation, a distributed aperture detection scheme is used in which the effective aperture size can be increased without the associated volumetric increase in imager size. This distributed aperture system is realized through conversion of the received mmW energy into sidebands on an optical carrier. This conversion serves, in essence, to scale the mmW sparse aperture array signals onto a complementary optical array. The side bands are subsequently stripped from the optical carrier and recombined to provide a real time snapshot of the mmW signal. Using this technique, we have constructed a real-time, video-rate imager operating at 75 GHz. A distributed aperture consisting of 220 upconversion channels is used to realize 2.5k pixels with passive sensitivity. Details of the construction and operation of this imager as well as field testing results will be presented herein.

  7. A Millimeter-Wave Quasi-Optical Circuit for Compact Triple-Band Receiving System

    Science.gov (United States)

    Han, Seog-Tae; Lee, Jung-Won; Lee, Bangwon; Chung, Moon-Hee; Lee, Sung-Mo; Je, Do-Heung; Wi, Seog-Oh; Goldsmith, Paul F.

    2017-12-01

    A novel receiver optical system designed for Korean VLBI Network (KVN) has been used for conducting simultaneous millimeter-wave very long baseline interferometry (VLBI) observations at frequencies of 22, 43, 86, and 129 GHz. This multi-frequency band receiver system has been effective in compensation of atmospheric phase fluctuation by unique phase referencing technique in mm-VLBI observations. However, because the original optics system incorporated individual cryogenic receivers in separate cryostats, a rather bulky optical bench of size about 2600 mm x 2300 mm x 60 mm was required. To circumvent difficulties in installation and beam alignment, an integrated quasi-optical circuit incorporating a more compact triple-band receiver in single cryostat is proposed in this paper. The recommended frequency bands of the improved triple-band receiver are K(18-26 GHz) band, Q(35-50 GHz) band, and W(85-115 GHz) band. A frequency-independent quasi-optical circuit for triple band is adopted to obtain constant aperture efficiency as a function of the observed frequencies. The simulation results show that total aperture efficiency of each recommended frequency band is maintained almost constant within 1%. We present the design details of the compact wideband quasi-optical circuit and the triple-band receiver optimized for simultaneous multi-frequency observations.

  8. Analysis on Human Blockage Path Loss and Shadow Fading in Millimeter-Wave Band

    Directory of Open Access Journals (Sweden)

    Hongmei Zhao

    2017-01-01

    Full Text Available Millimeter-wave (Mm-w is the trend of communication development in the future; users who carry mobile communication equipment could be blocked by others in a crowded population environment. Based on Shooting and Bouncing Ray (SBR method and setting up different orientation receivers (RX, population density, and people fabric property at 28 GHz and 38 GHz, simulating experimental scene similar to station square by Wireless Insite software, we use least square method to do linear-regression analysis for path loss and build path loss model. The result shows that the path loss index has a certain change in the different frequency, orientation receivers, population density, and people fabric. The path loss index of RouteC1 and RouteA2 has an obvious change in the central transmitter (TX. Each route shadow fading obeys Gaussian distribution whose mean is 0. This paper’s result has a theoretical guiding for designing the communication system in a crowded population environment.

  9. Proof-of-Concept of a Millimeter-Wave Integrated Heterogeneous Network for 5G Cellular.

    Science.gov (United States)

    Okasaka, Shozo; Weiler, Richard J; Keusgen, Wilhelm; Pudeyev, Andrey; Maltsev, Alexander; Karls, Ingolf; Sakaguchi, Kei

    2016-08-25

    The fifth-generation mobile networks (5G) will not only enhance mobile broadband services, but also enable connectivity for a massive number of Internet-of-Things devices, such as wireless sensors, meters or actuators. Thus, 5G is expected to achieve a 1000-fold or more increase in capacity over 4G. The use of the millimeter-wave (mmWave) spectrum is a key enabler to allowing 5G to achieve such enhancement in capacity. To fully utilize the mmWave spectrum, 5G is expected to adopt a heterogeneous network (HetNet) architecture, wherein mmWave small cells are overlaid onto a conventional macro-cellular network. In the mmWave-integrated HetNet, splitting of the control plane (CP) and user plane (UP) will allow continuous connectivity and increase the capacity of the mmWave small cells. mmWave communication can be used not only for access linking, but also for wireless backhaul linking, which will facilitate the installation of mmWave small cells. In this study, a proof-of-concept (PoC) was conducted to demonstrate the practicality of a prototype mmWave-integrated HetNet, using mmWave technologies for both backhaul and access.

  10. Proof-of-Concept of a Millimeter-Wave Integrated Heterogeneous Network for 5G Cellular

    Directory of Open Access Journals (Sweden)

    Shozo Okasaka

    2016-08-01

    Full Text Available The fifth-generation mobile networks (5G will not only enhance mobile broadband services, but also enable connectivity for a massive number of Internet-of-Things devices, such as wireless sensors, meters or actuators. Thus, 5G is expected to achieve a 1000-fold or more increase in capacity over 4G. The use of the millimeter-wave (mmWave spectrum is a key enabler to allowing 5G to achieve such enhancement in capacity. To fully utilize the mmWave spectrum, 5G is expected to adopt a heterogeneous network (HetNet architecture, wherein mmWave small cells are overlaid onto a conventional macro-cellular network. In the mmWave-integrated HetNet, splitting of the control plane (CP and user plane (UP will allow continuous connectivity and increase the capacity of the mmWave small cells. mmWave communication can be used not only for access linking, but also for wireless backhaul linking, which will facilitate the installation of mmWave small cells. In this study, a proof-of-concept (PoC was conducted to demonstrate the practicality of a prototype mmWave-integrated HetNet, using mmWave technologies for both backhaul and access.

  11. Enhancing Secrecy With Multiantenna Transmission in Millimeter Wave Vehicular Communication Systems

    KAUST Repository

    Eltayeb, Mohammed E.

    2017-03-14

    Millimeter wave (mmWave) vehicular communication systems will provide an abundance of bandwidth for the exchange of raw sensor data and support driver-assisted and safety-related functionalities. Lack of secure communication links, however, may lead to abuses and attacks that jeopardize the efficiency of transportation systems and the physical safety of drivers. In this paper, we propose two physical layer (PHY) security techniques for vehicular mmWave communication systems. The first technique uses multiple antennas with a single radio-frequency (RF) chain to transmit information symbols to a target receiver and noise-like signals in nonreceiver directions. The second technique uses multiple antennas with a few RF chains to transmit information symbols to a target receiver and opportunistically inject artificial noise in controlled directions, thereby reducing interference in vehicular environments. Theoretical and numerical results show that the proposed techniques provide higher secrecy rate when compared to traditional PHY security techniques that require digital or more complex antenna architectures.

  12. Compressive Sensing for Blockage Detection in Vehicular Millimeter Wave Antenna Arrays

    KAUST Repository

    Eltayeb, Mohammed E.

    2017-02-07

    The radiation pattern of an antenna array depends on the excitation weights and the geometry of the array. Due to mobility, some vehicular antenna elements might be subjected to full or partial blockages from a plethora of particles like dirt, salt, ice, and water droplets. These particles cause absorption and scattering to the signal incident on the array, and as a result, change the array geometry. This distorts the radiation pattern of the array mostly with an increase in the sidelobe level and decrease in gain. In this paper, we propose a blockage detection technique for millimeter wave vehicular antenna arrays that jointly estimates the locations of the blocked antennas and the attenuation and phase-shifts that result from the suspended particles. The proposed technique does not require the antenna array to be physically removed from the vehicle and permits real-time array diagnosis. Numerical results show that the proposed technique provides satisfactory results in terms of block detection with low detection time provided that the number of blockages is small compared to the array size.

  13. Effects of millimeter wave carbon fibers on filter-feeding freshwater invertebrates.

    Science.gov (United States)

    Soucek, David J; Dickinson, Amy; Cropek, Donald M

    2010-05-01

    The purpose of our study was to investigate the sub-lethal effects of millimeter wave carbon fibers (MWCF), a military obscurant, on filter-feeding freshwater invertebrates. We observed decreased survival, reproduction, and oxygen consumption in Daphnia magna at realistic loading rates. In experiments with the Asiatic clam (Corbicula fluminea), soft tissue dry weight and tissue condition index were not significantly different among control and MWCF exposed treatments; however, using a (15)N labeled alga as food, we observed decreased nitrogen turnover in tissues of clams exposed to MWCF, suggesting lower filtering or ingestion rates. Our findings combined with previous demonstrations of MWCF toxicity to green algae suggest that over a period of several months, bivalve growth may be inhibited, and cladoceran populations may be even more strongly affected by MWCF. Given that these fibers are persistent, further experiments should be conducted to determine the longer-term effects of contamination of water bodies with MWCF. Copyright 2009 Elsevier Inc. All rights reserved.

  14. FGG-NUFFT-Based Method for Near-Field 3-D Imaging Using Millimeter Waves.

    Science.gov (United States)

    Kan, Yingzhi; Zhu, Yongfeng; Tang, Liang; Fu, Qiang; Pei, Hucheng

    2016-09-19

    In this paper, to deal with the concealed target detection problem, an accurate and efficient algorithm for near-field millimeter wave three-dimensional (3-D) imaging is proposed that uses a two-dimensional (2-D) plane antenna array. First, a two-dimensional fast Fourier transform (FFT) is performed on the scattered data along the antenna array plane. Then, a phase shift is performed to compensate for the spherical wave effect. Finally, fast Gaussian gridding based nonuniform FFT (FGG-NUFFT) combined with 2-D inverse FFT (IFFT) is performed on the nonuniform 3-D spatial spectrum in the frequency wavenumber domain to achieve 3-D imaging. The conventional method for near-field 3-D imaging uses Stolt interpolation to obtain uniform spatial spectrum samples and performs 3-D IFFT to reconstruct a 3-D image. Compared with the conventional method, our FGG-NUFFT based method is comparable in both efficiency and accuracy in the full sampled case and can obtain more accurate images with less clutter and fewer noisy artifacts in the down-sampled case, which are good properties for practical applications. Both simulation and experimental results demonstrate that the FGG-NUFFT-based near-field 3-D imaging algorithm can have better imaging performance than the conventional method for down-sampled measurements.

  15. FGG-NUFFT-Based Method for Near-Field 3-D Imaging Using Millimeter Waves

    Directory of Open Access Journals (Sweden)

    Yingzhi Kan

    2016-09-01

    Full Text Available In this paper, to deal with the concealed target detection problem, an accurate and efficient algorithm for near-field millimeter wave three-dimensional (3-D imaging is proposed that uses a two-dimensional (2-D plane antenna array. First, a two-dimensional fast Fourier transform (FFT is performed on the scattered data along the antenna array plane. Then, a phase shift is performed to compensate for the spherical wave effect. Finally, fast Gaussian gridding based nonuniform FFT (FGG-NUFFT combined with 2-D inverse FFT (IFFT is performed on the nonuniform 3-D spatial spectrum in the frequency wavenumber domain to achieve 3-D imaging. The conventional method for near-field 3-D imaging uses Stolt interpolation to obtain uniform spatial spectrum samples and performs 3-D IFFT to reconstruct a 3-D image. Compared with the conventional method, our FGG-NUFFT based method is comparable in both efficiency and accuracy in the full sampled case and can obtain more accurate images with less clutter and fewer noisy artifacts in the down-sampled case, which are good properties for practical applications. Both simulation and experimental results demonstrate that the FGG-NUFFT-based near-field 3-D imaging algorithm can have better imaging performance than the conventional method for down-sampled measurements.

  16. Integrating Millimeter Wave Radar with a Monocular Vision Sensor for On-Road Obstacle Detection Applications

    Directory of Open Access Journals (Sweden)

    Zheng Ma

    2011-09-01

    Full Text Available This paper presents a systematic scheme for fusing millimeter wave (MMW radar and a monocular vision sensor for on-road obstacle detection. As a whole, a three-level fusion strategy based on visual attention mechanism and driver’s visual consciousness is provided for MMW radar and monocular vision fusion so as to obtain better comprehensive performance. Then an experimental method for radar-vision point alignment for easy operation with no reflection intensity of radar and special tool requirements is put forward. Furthermore, a region searching approach for potential target detection is derived in order to decrease the image processing time. An adaptive thresholding algorithm based on a new understanding of shadows in the image is adopted for obstacle detection, and edge detection is used to assist in determining the boundary of obstacles. The proposed fusion approach is verified through real experimental examples of on-road vehicle/pedestrian detection. In the end, the experimental results show that the proposed method is simple and feasible.

  17. Developing an ANSI standard for image quality tools for the testing of active millimeter wave imaging systems

    Science.gov (United States)

    Barber, Jeffrey; Greca, Joseph; Yam, Kevin; Weatherall, James C.; Smith, Peter R.; Smith, Barry T.

    2017-05-01

    In 2016, the millimeter wave (MMW) imaging community initiated the formation of a standard for millimeter wave image quality metrics. This new standard, American National Standards Institute (ANSI) N42.59, will apply to active MMW systems for security screening of humans. The Electromagnetic Signatures of Explosives Laboratory at the Transportation Security Laboratory is supporting the ANSI standards process via the creation of initial prototypes for round-robin testing with MMW imaging system manufacturers and experts. Results obtained for these prototypes will be used to inform the community and lead to consensus objective standards amongst stakeholders. Images collected with laboratory systems are presented along with results of preliminary image analysis. Future directions for object design, data collection and image processing are discussed.

  18. System Coverage and Capacity Analysis on Millimeter-Wave Band for 5G Mobile Communication Systems with Massive Antenna Structure

    Directory of Open Access Journals (Sweden)

    Jun Suk Kim

    2014-01-01

    Full Text Available The use of a millimeter-wave band defined as a 30–300 GHz range is significant element for improving performance of 5th generation (5G mobile communication systems. However, since the millimeter-wave signal has peculiar propagation characteristics especially toward non-line-of-sight regions, the system architecture and antenna structure for 5G mobile communications should be designed to overcome these propagation limitations. For realization of the 5G mobile communications, electronics and telecommunications research institute (ETRI is developing central network applying various massive antenna structures with beamforming. In this paper, we have introduced the central network and evaluated the system coverage and capacity through C++ language-based simulations with real geospatial information.

  19. Statistical Channel Model with Multi-Frequency and Arbitrary Antenna Beamwidth for Millimeter-Wave Outdoor Communications

    OpenAIRE

    Samimi, Mathew K.; Rappaport, Theodore S.

    2015-01-01

    This paper presents a 3-dimensional millimeter-wave statistical channel impulse response model from 28 GHz and 73 GHz ultrawideband propagation measurements. An accurate 3GPP-like channel model that supports arbitrary carrier frequency, RF bandwidth, and antenna beamwidth (for both omnidirectional and arbitrary directional antennas), is provided. Time cluster and spatial lobe model parameters are extracted from empirical distributions from field measurements. A step-by-step modeling procedure...

  20. Traveling-Wave Tube Amplifier Second Harmonic as Millimeter-Wave Beacon Source for Atmospheric Propagation Studies

    Science.gov (United States)

    Simons, Rainee N.; Wintucky, Edwin G.

    2014-01-01

    This paper presents the design and test results of a CW millimeter-wave satellite beacon source, based on the second harmonic from a traveling-wave tube amplifier and utilizes a novel waveguide multimode directional coupler. A potential application of the beacon source is for investigating the atmospheric effects on Q-band (37-42 GHz) and V/W-band (71- 76 GHz) satellite-to-ground signals.

  1. W-Band Millimeter-Wave Vector Signal Generation Based on Precoding-Assisted Random Photonic Frequency Tripling Scheme Enabled by Phase Modulator

    National Research Council Canada - National Science Library

    Li, Xinying; Xu, Yuming; Xiao, Jiangnan; Yu, Jianjun

    2016-01-01

    We propose W-band photonic millimeter-wave (mm-wave) vector signal generation employing a precoding-assisted random frequency tripling scheme enabled by a single phase modulator cascaded with a wavelength selective switch (WSS...

  2. Development of a high power free-electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Min; Lee, Byung Chul; Kim, Sun Kook; Jung, Yung Wook; Cho, Sung Oh [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-01-01

    A millimeter-wave free electron laser (FEL) driven by a recirculating electrostatic accelerator has been developed. The wavelength of the FEL is tunable in the range of 3 - 12 mm by tuning the energy of the electron beam. The output power is estimated to be 1 kW. The electrostatic accelerator is composed of high-current electron gun, acceleration tube, high-voltage generator, high-voltage terminal, deceleration tube, electron collator, and vacuum pumps. Two types of LaB{sub 6}-based thermionic electron guns (triode gun and diode gun) and their power supplies have been developed. The voltage of the guns is 30 kV and the output current is - 2 A. A beam-focusing planar undulator and a permanent-magnet helical undulator have been developed and 3D trajectories of electron beam in the undulators have been calculated to find optimal input condition of electron beam. 135 figs, 15 pix, 17 tabs, 98 refs. (Author).

  3. Experimental methods of indoor millimeter-wave radiometric imaging for personnel concealed contraband detection

    Science.gov (United States)

    Hu, Taiyang; Xiao, Zelong; Li, Hao; Lv, Rongchuan; Lu, Xuan

    2014-11-01

    The increasingly emerging terrorism attacks and violence crimes around the world have posed severe threats to public security, so carrying out relevant research on advanced experimental methods of personnel concealed contraband detection is crucial and meaningful. All of the advantages of imaging covertly, avoidance of interference with other systems, intrinsic property of being safe to persons under screening , and the superior ability of imaging through natural or manmade obscurants, have significantly combined to enable millimeter-wave (MMW) radiometric imaging to offer great potential in personnel concealed contraband detection. Based upon the current research status of MMW radiometric imaging and urgent demands of personnel security screening, this paper mainly focuses on the experimental methods of indoor MMW radiometric imaging. The reverse radiation noise resulting from super-heterodyne receivers seriously affects the image experiments carried out at short range, so both the generation mechanism and reducing methods of this noise are investigated. Then, the benefit of sky illumination no longer exists for the indoor radiometric imaging, and this leads to the decrease in radiometric temperature contrast between target and background. In order to enhance the radiometric temperature contrast for improving indoor imaging performance, the noise illumination technique is adopted in the indoor imaging scenario. In addition, the speed and accuracy of concealed contraband detection from acquired MMW radiometric images are usually restricted to the deficiencies in traditional artificial interpretation by security inspectors, thus an automatic recognition and location algorithm by integrating improved Fuzzy C-means clustering with moment invariants is put forward. A series of original results are also presented to demonstrate the significance and validity of these methods.

  4. Photonic methods of millimeter-wave generation based on Brillouin fiber laser

    Science.gov (United States)

    Al-Dabbagh, R. K.; Al-Raweshidy, H. S.

    2016-05-01

    In optical communication link, generation and delivering millimeter-wave (mm-waves) in radio over fiber (RoF) systems has limitation due to fiber non-linearity effects. To solve this problem, photonic methods of mm-wave generation based on characterizations of Brillouin fiber laser are proposed in this work for the first time. Three novel photonic approaches for mm-wave generation methods based on Brillouin fiber laser and phase modulator are proposed and demonstrated by simulation. According to our theoretical analysis and simulation, mm-waves with frequency up to 80 GHz and good signal to noise ratio (SNR) up to 90 dB are generated by new and cost effective methods of generation that make them suitable for applications of the fifth generation (5G) networks. The proposed configurations increase the stability and the quality of the mm-wave generation system by using a single laser source as a pump wave and the fiber non-linearity effects are reduced. A key advantage of this research is that proposed a number of very simple generation methods and cost effective which only use standard components of optical telecommunications. Stimulated Brillouin Scattering (SBS) effect that exists in the optical fiber is studied with the characterization of phase modulator. An all optically stable mm-wave carriers are achieved successfully in the three different methods with different frequencies from 20 GHz up to 80 GHz. Simulation results show that all these carriers have low phase noise, good SNR ranging between 60 and 90 dB and tuning capability in comparison with previous methods reported. This makes them suitable for mm-wave transmission in RoF systems to transmit data in the next generation networks.

  5. Millimeter Wave Spectrum of Methyl Ketene and its Search in Orion

    Science.gov (United States)

    Bermúdez, Celina; Margulès, L.; Motiyenko, R. A.; Tercero, Belén; Cernicharo, Jose; Guillemin, J.-C.; Ellinger, Y.

    2017-06-01

    The knowledge of synthetic routes of complex organic molecules is still far to be fully understood. The creation of reliable models is particularly challenging. Hollis et al. pointed out that the observations of molecular isomers provides an excellent tool to evaluate the hypothesis of the synthetic pathways. In the group of isomers C_3H_4O that contains two unsaturations, the three most stable are cyclopropanone, propenal (also known as acrolein) and methyl ketene. Among these isomers, only propenal was tentatively detected in Sgr B2(N). Spectroscopic measurements of methyl ketene CH_3CHCO are limited to the microwave domain. We extended the measurements into millimeter waves in order to provide accurate frequency predictions suitable for astrophysical purposes. Methyl ketene has one more carbon atom than acetaldehyde (CH_3CHO) and in terms of rotational spectroscopy is quite similar to acetaldehyde. The analysis of the rotational spectrum of methyl ketene is complicated due to internal rotation of the methyl group, that is characterized by the barrier of intermediate height V_3 = 416 \\wn, and by quite large value of the coupling parameter ρ = 0.194. The spectroscopic results and the searches of methyl ketene in Orion will be presented. This work was supported by the CNES and the Action sur Projets de l'INSU, PCMI. This work was also done under ANR-13-BS05-0008-02 IMOLABS Hollis, J. M.; 2006, ApJ 642, 933 Hollis, J. M.; et al., 2006, ApJ 643, L25 Bak, B.; et al., 1966, J. Chez. Phys. 45, 883

  6. Novel low-cost millimeter-wave system for road surface characterization

    Science.gov (United States)

    Busuioc, Dan; Anstey, Kyle; Rappaport, Carey; Birken, Ralf; Doughty, Jeffrey; Wang, Ming

    2011-04-01

    A novel low-cost low-complexity design based on Radar technology operating at millimeter wave is presented for the characterization of road surface conditions in real-time. At frequencies of 24-77 GHz the wavelength is long enough to obtain slight penetration in the top 1-2" of asphalt or concrete surface, but is also short enough to resolve details such as crack or pothole depth/etc. The Radar system operates by continuously outputting radiation and sampling the roadway-reflected radiation through a receiver-downconverter-sampler system. In initial laboratory testing, the received signal strength was observed to obey the inverse distance 1/R2 relationship. The received signal is further dependent on the incidence angle between the plane of the sensor and the plane of the roadway. One observation from this is the need of auxiliary sensors for determining the distance above the road surface as well as providing incident angle data. The sensor was further mounted on a movable cart used to measure the reflected signal on a variety of road surfaces (smooth, rough, surface defects, and environment factors such as various levels of moisture). By comparing measurements of the material after soaking to measurements in the dry state, there is substantial differentiation in measurements, which indicates the ability to measure the porosity of various materials. Lastly the sensor bandwidth provides the capability to measure surface roughness illustrated in the standard deviation of measurement data. On a macroscopic level, the aggregate in a roadway acts as a series of random scatterers and rough roadways or roadways with surface voids show a large variance between measurements of nearby points.

  7. Microwave and Millimeter Wave Nondestructive Evaluation of the Space Shuttle External Tank Insulating Foam

    Science.gov (United States)

    Shrestha, S.; Kharkovsky, S.; Zoughi, R.; Hepburn, F

    2005-01-01

    The Space Shuttle Columbia s catastrophic failure has been attributed to a piece of external fuel tank insulating SOFI (Spray On Foam Insulation) foam striking the leading edge of the left wing of the orbiter causing significant damage to some of the protecting heat tiles. The accident emphasizes the growing need to develop effective, robust and life-cycle oriented methods of nondestructive testing and evaluation (NDT&E) of complex conductor-backed insulating foam and protective acreage heat tiles used in the space shuttle fleet and in future multi-launch space vehicles. The insulating SOFI foam is constructed from closed-cell foam. In the microwave regime this foam is in the family of low permittivity and low loss dielectric materials. Near-field microwave and millimeter wave NDT methods were one of the techniques chosen for this purpose. To this end several flat and thick SOFI foam panels, two structurally complex panels similar to the external fuel tank and a "blind" panel were used in this investigation. Several anomalies such as voids and disbonds were embedded in these panels at various locations. The location and properties of the embedded anomalies in the "blind" panel were not disclosed to the investigating team prior to the investigation. Three frequency bands were used in this investigation covering a frequency range of 8-75 GHz. Moreover, the influence of signal polarization was also investigated. Overall the results of this investigation were very promising for detecting the presence of anomalies in different panels covered with relatively thick insulating SOFI foam. Different types of anomalies were detected in foam up to 9 in thick. Many of the anomalies in the more complex panels were also detected. When investigating the blind panel no false positives were detected. Anomalies in between and underneath bolt heads were not easily detected. This paper presents the results of this investigation along with a discussion of the capabilities of the method

  8. Rotational study of the NH3-CO complex: millimeter-wave measurements and ab initio calculations.

    Science.gov (United States)

    Surin, L A; Potapov, A; Dolgov, A A; Tarabukin, I V; Panfilov, V A; Schlemmer, S; Kalugina, Y N; Faure, A; van der Avoird, A

    2015-03-21

    The rotational spectrum of the van der Waals complex NH3-CO has been measured with the intracavity OROTRON jet spectrometer in the frequency range of 112-139 GHz. Newly observed and assigned transitions belong to the K = 0-0, K = 1-1, K = 1-0, and K = 2-1 subbands correlating with the rotationless (jk)NH3 = 00 ground state of free ortho-NH3 and the K = 0-1 and K = 2-1 subbands correlating with the (jk)NH3 = 11 ground state of free para-NH3. The (approximate) quantum number K is the projection of the total angular momentum J on the intermolecular axis. Some of these transitions are continuations to higher J values of transition series observed previously [C. Xia et al., Mol. Phys. 99, 643 (2001)], the other transitions constitute newly detected subbands. The new data were analyzed together with the known millimeter-wave and microwave transitions in order to determine the molecular parameters of the ortho-NH3-CO and para-NH3-CO complexes. Accompanying ab initio calculations of the intermolecular potential energy surface (PES) of NH3-CO has been carried out at the explicitly correlated coupled cluster level of theory with single, double, and perturbative triple excitations and an augmented correlation-consistent triple zeta basis set. The global minimum of the five-dimensional PES corresponds to an approximately T-shaped structure with the N atom closest to the CO subunit and binding energy De = 359.21 cm(-1). The bound rovibrational levels of the NH3-CO complex were calculated for total angular momentum J = 0-6 on this intermolecular potential surface and compared with the experimental results. The calculated dissociation energies D0 are 210.43 and 218.66 cm(-1) for ortho-NH3-CO and para-NH3-CO, respectively.

  9. High Speed On-Wafer Characterization Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — At the High Speed On-Wafer Characterization Laboratory, researchers characterize and model devices operating at terahertz (THz) and millimeter-wave frequencies. The...

  10. Real time three-dimensional space video rate sensors for millimeter waves imaging based very inexpensive plasma LED lamps

    Science.gov (United States)

    Levanon, Assaf; Yitzhaky, Yitzhak; Kopeika, Natan S.; Rozban, Daniel; Abramovich, Amir

    2014-10-01

    In recent years, much effort has been invested to develop inexpensive but sensitive Millimeter Wave (MMW) detectors that can be used in focal plane arrays (FPAs), in order to implement real time MMW imaging. Real time MMW imaging systems are required for many varied applications in many fields as homeland security, medicine, communications, military products and space technology. It is mainly because this radiation has high penetration and good navigability through dust storm, fog, heavy rain, dielectric materials, biological tissue, and diverse materials. Moreover, the atmospheric attenuation in this range of the spectrum is relatively low and the scattering is also low compared to NIR and VIS. The lack of inexpensive room temperature imaging systems makes it difficult to provide a suitable MMW system for many of the above applications. In last few years we advanced in research and development of sensors using very inexpensive (30-50 cents) Glow Discharge Detector (GDD) plasma indicator lamps as MMW detectors. This paper presents three kinds of GDD sensor based lamp Focal Plane Arrays (FPA). Those three kinds of cameras are different in the number of detectors, scanning operation, and detection method. The 1st and 2nd generations are 8 × 8 pixel array and an 18 × 2 mono-rail scanner array respectively, both of them for direct detection and limited to fixed imaging. The last designed sensor is a multiplexing frame rate of 16x16 GDD FPA. It permits real time video rate imaging of 30 frames/ sec and comprehensive 3D MMW imaging. The principle of detection in this sensor is a frequency modulated continuous wave (FMCW) system while each of the 16 GDD pixel lines is sampled simultaneously. Direct detection is also possible and can be done with a friendly user interface. This FPA sensor is built over 256 commercial GDD lamps with 3 mm diameter International Light, Inc., Peabody, MA model 527 Ne indicator lamps as pixel detectors. All three sensors are fully supported

  11. Millimeter wave spectroscopic measurements of stratospheric and mesospheric constituents over the Italian Alps: stratospheric ozone

    Directory of Open Access Journals (Sweden)

    V. Romaniello

    2007-06-01

    Full Text Available Measurements of rotational lines emitted by middle atmospheric trace gases have been carried out from the Alpine station of Testa Grigia (45.9°N, 7.7°E, elev. 3500 m by means of a Ground-Based Millimeter-wave Spectrometer (GBMS. Observations of species such as O3, HNO3, CO, N2O, HCN, and HDO took place during 4 winter periods, from February 2004 to March 2007, for a total of 116 days of measurements grouped in about 18 field campaigns. By studying the pressure-broadened shape of emission lines the vertical distribution of the observed constituents is retrieved within an altitude range of ?17-75 km, constrained by the 600 MHz pass band and the 65 kHz spectral resolution of the back-end spectrometer. This work discusses the behavior of stratospheric O3 during the entire period of operation at Testa Grigia. Mid-latitude O3 columnar content as estimated using GBMS measurements can vary by large amounts over a period of very few days, with the largest variations observed in December 2005, February 2006, and March 2006, confirming that the northern winter of 2005-2006 was characterized by a particularly intense planetary wave activity. The largest rapid variation from maximum to minimum O3 column values over Testa Grigia took place in December 2006 and reached a relative value of 72% with respect to the average column content for that period. During most GBMS observation times much of the variability is concentrated in the column below 20 km, with tropospheric weather systems and advection of tropical tropospheric air into the lower stratosphere over Testa Grigia having a large impact on the observed variations in column contents. Nonetheless, a wide variability is also found in middle stratospheric GBMS O3 measurements, as expected for mid-latitude ozone. We find that O3 mixing ratios at ?32 km are very well correlated with the solar illumination experienced by air masses over the previous ?15 days, showing that already at 32 km

  12. Microwave and Millimeter-Wave Radiometric Studies of Temperature, Water Vapor and Clouds

    Energy Technology Data Exchange (ETDEWEB)

    Westwater, Edgeworth

    2011-05-06

    The importance of accurate measurements of column amounts of water vapor and cloud liquid has been well documented by scientists within the Atmospheric Radiation Measurement (ARM) Program. At the North Slope of Alaska (NSA), both microwave radiometers (MWR) and the MWRProfiler (MWRP), been used operationally by ARM for passive retrievals of the quantities: Precipitable Water Vapor (PWV) and Liquid Water Path (LWP). However, it has been convincingly shown that these instruments are inadequate to measure low amounts of PWV and LWP. In the case of water vapor, this is especially important during the Arctic winter, when PWV is frequently less than 2 mm. For low amounts of LWP (< 50 g/m{sup 2}), the MWR and MWRP retrievals have an accuracy that is also not acceptable. To address some of these needs, in March-April 2004, NOAA and ARM conducted the NSA Arctic Winter Radiometric Experiment - Water Vapor Intensive Operational Period at the ARM NSA/Adjacent Arctic Ocean (NSA/AAO) site. After this experiment, the radiometer group at NOAA moved to the Center for Environmental Technology (CET) of the Department of Electrical and Computer Engineering of the University of Colorado at Boulder. During this 2004 experiment, a total of 220 radiosondes were launched, and radiometric data from 22.235 to 380 GHz were obtained. Primary instruments included the ARM MWR and MWRP, a Global Positioning System (GPS), as well as the CET Ground-based Scanning Radiometer (GSR). We have analyzed data from these instruments to answer several questions of importance to ARM, including: (a) techniques for improved water vapor measurements; (b) improved calibration techniques during cloudy conditions; (c) the spectral response of radiometers to a variety of conditions: clear, liquid, ice, and mixed phase clouds; and (d) forward modeling of microwave and millimeter wave brightness temperatures from 22 to 380 GHz. Many of these results have been published in the open literature. During the third year of

  13. Electro-optic millimeter-wave harmonic downconversion and vector demodulation using cascaded phase modulation and optical filtering.

    Science.gov (United States)

    Pagán, Vincent R; Murphy, Thomas E

    2015-06-01

    We describe and demonstrate an electro-optic technique to simultaneously downconvert and demodulate vector-modulated millimeter-wave signals. The system uses electro-optic phase modulation and optical filtering to perform harmonic downconversion of the RF signal to an intermediate frequency (IF) or to baseband. We demonstrate downconversion of RF signals between 7 and 70-GHz to IFs below 20-GHz. Furthermore, we show harmonic downconversion and vector demodulation of 2.5-Gb/s QPSK and 5-Gb/s 16-QAM signals at carrier frequencies of 40-GHz to baseband.

  14. Measurements of the Complex Permittivity of Liquid Helium-4 in the Millimeter Wave Range by a Whispering Gallery Mode Resonator

    Science.gov (United States)

    Smorodin, A. V.; Rybalko, A. S.; Konstantinov, D.

    2017-06-01

    We report an experimental study of the electrical properties of liquid helium-4 in the temperature range 1.2-3 K. The experiment is carried out in the millimeter wave range using a whispering gallery mode dielectric resonator, and the complex permittivity of liquid helium is extracted from the data using the resonant perturbation method. The results for the temperature dependence of the dielectric constant are consistent with the previous studies. In addition, we find strong enhancement of the loss tangent around the superfluid transition temperature.

  15. Multi-frequency force-detected electron spin resonance in the millimeter-wave region up to 150 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Ohmichi, E., E-mail: ohmichi@harbor.kobe-u.ac.jp; Tokuda, Y.; Tabuse, R.; Tsubokura, D.; Okamoto, T. [Graduate School of Science, Kobe University, 1-1 Rokkodai-cho, Nada, Kobe 657-8501 (Japan); Ohta, H. [Molecular Photoscience Research Center, Kobe University, 1-1 Rokkodai-cho, Nada, Kobe 657-8501 (Japan)

    2016-07-15

    In this article, a novel technique is developed for multi-frequency force-detected electron spin resonance (ESR) in the millimeter-wave region. We constructed a compact ESR probehead, in which the cantilever bending is sensitively detected by a fiber-optic Fabry-Perot interferometer. With this setup, ESR absorption of diphenyl-picrylhydrazyl radical (<1 μg) was clearly observed at multiple frequencies of up to 150 GHz. We also observed the hyperfine splitting of low-concentration Mn{sup 2+} impurities(∼0.2%) in MgO.

  16. Millimeter-wave response and linewidth of Josephson oscillations in YBa2Cu3O7 step-edge junctions

    DEFF Research Database (Denmark)

    Divin, Yu. Ya.; Andreev, A. V.; Fischer, Gerd Michael

    1993-01-01

    We have studied the response of YBa2Cu3O7 step-edge junctions to low-intensity millimeter-wave radiation in the temperature range from 4 to 80 K. The linewidth of the Josephson oscillations derived from the resonant part of the response at voltages V congruent-to (h/2e)f is shown to be determined...... by thermal fluctuations at liquid nitrogen temperatures. At lower temperatures the observed linewidth increases indicating that low-frequency fluctuations become dominant in the junction as the temperature is reduced. Due to an inhomogeneous spatial distribution of the current the step-edge junction might...

  17. Millimeter wave silicon micromachined waveguide probe as an aid for skin diagnosis--results of measurements on phantom material with varied water content.

    Science.gov (United States)

    Dancila, D; Augustine, R; Töpfer, F; Dudorov, S; Hu, X; Emtestam, L; Tenerz, L; Oberhammer, J; Rydberg, A

    2014-02-01

    More than 2 million cases of skin cancer are diagnosed annually in the United States, which makes it the most common form of cancer in that country. Early detection of cancer usually results in less extensive treatment and better outcome for the patient. Millimeter wave silicon micromachined waveguide probe is foreseen as an aid for skin diagnosis, which is currently based on visual inspection followed by biopsy, in cases where the macroscopical picture raises suspicion of malignancy. Demonstration of the discrimination potential of tissues of different water content using a novel micromachined silicon waveguide probe. Secondarily, the silicon probe miniaturization till an inspection area of 600 × 200 μm2, representing a drastic reduction by 96.3% of the probing area, in comparison with a conventional WR-10 waveguide. The high planar resolution is required for histology and early-state skin-cancer detection. To evaluate the probe three phantoms with different water contents, i.e. 50%, 75% and 95%, mimicking dielectric properties of human skin were characterized in the frequency range of 95-105 GHz. The complex permittivity values of the skin are obtained from the variation in frequency and amplitude of the reflection coefficient (S11), measured with a Vector Network Analyzer (VNA), by comparison with finite elements simulations of the measurement set-up, using the commercially available software, HFSS. The expected frequency variation is calculated with HFSS and is based on extrapolated complex permittivities, using one relaxation Debye model from permittivity measurements obtained using the Agilent probe. Millimeter wave reflection measurements were performed using the probe in the frequency range of 95-105 GHz with three phantoms materials and air. Intermediate measurement results are in good agreement with HFSS simulations, based on the extrapolated complex permittivity. The resonance frequency lowers, from the idle situation when it is probing air

  18. Basic examination of a technique to visualize space filled with dense smoke using millimeter-wave radar

    Science.gov (United States)

    Omine, Yukio; Sakai, Masaki; Aoki, Yoshimitsu; Takagi, Mikio

    2004-10-01

    In recent years, crisis management in response to terrorist attacks and natural disasters, as well as accelerating rescue operations has become an important issue. Rescue operations greatly influence human lives, and require the ability to accurately and swiftly communicate information as well as assess the status of the site. Currently, considerable amount of research is being conducted for assisting rescue operations, with the application of various engineering techniques such as information technology and radar technology. In the present research, we believe that assessing the status of the site is most crucial in rescue and firefighting operations at a fire disaster site, and aim to visualize the space that is smothered with dense smoke. In a space filled with dense smoke, where visual or infrared sensing techniques are not feasible, three-dimensional measurements can be realized using a compact millimeter wave radar device combined with directional information from a gyro sensor. Using these techniques, we construct a system that can build and visualize a three-dimensional geometric model of the space. The final objective is to implement such a system on a wearable computer, which will improve the firefighters' spatial perception, assisting them in the baseline assessment and the decision-making process. In the present paper, we report the results of the basic experiments on three-dimensional measurement and visualization of a space that is smoke free, using a millimeter wave radar.

  19. Effect of cooling on the efficiency of Schottky varactor frequency multipliers at millimeter waves

    Science.gov (United States)

    Louhi, Jyrki; Raiesanen, Antti; Erickson, Neal

    1992-01-01

    The efficiency of the Schottky diode multiplier can be increased by cooling the diode to 77 K. The main reason for better efficiency is the increased mobility of the free carriers. Because of that the series resistance decreases and a few dB higher efficiency can be expected at low input power levels. At high output frequencies and at high power levels, the current saturation decreases the efficiency of the multiplication. When the diode is cooled the maximum current of the diode increases and much more output power can be expected. There are also slight changes in the I-V characteristic and in the diode junction capacitance, but they have a negligible effect on the efficiency of the multiplier.

  20. Millimeter Wave Systems for Airports and Short-Range Aviation Communications: A Survey of the Current Channel Models at mmWave Frequencies

    Science.gov (United States)

    Khatun, Mahfuza; Mehrpouyan, Hani; Matolak, David; Guvenc, Ismail

    2017-01-01

    Millimeter-wave (mmWave) communications will play a key role in enhancing the throughput, reliability, and security of next generation wireless networks. These advancements are achieved through the large bandwidth available in this band and through the use of highly directional links that will be used to overcome the large pathloss at these frequencies. Although the terrestrial application of mmWave systems is advancing at a rapid pace, the use of mmWave communication systems in aviation systems or airports is still in its infancy. This can be attributed to the challenges related to radio technology and lack of development, and characterization of mmWave wireless channels for the aviation field and the airport environment. Consequently, one of our goals is to develop methodologies that support mmWave air to ground links, and various links at airports, by applying new localization schemes that allow for application of highly directional links that can be deployed over longer distances despite the high path loss at mmWave frequencies. However, a very thorough understanding of the mmWave channel models are needed to enable such new applications. To this end, in this paper, we present a survey of the current channel models in the mmWave band. The 3-dimensional statistical channel model is also reviewed and its parameters and typical characteristics for this model are identified and computed through simulation for the Boise metropolitan area.

  1. Near-millimeter-wave response of high Tc ramp-type Josephson Junctions

    NARCIS (Netherlands)

    Gupta, R.; Hu, Qing; Terpstra, D.; Terpstra, D.; Gerritsma, G.J.; Rogalla, Horst

    1993-01-01

    We have studied the response of a YBCO/PBCO/YBCO ramp‐type junction to coherent radiation at 176 and 270 GHz. The I‐V characteristic of the junction closely resembles the prediction of the RSJ model. The I cR n product of the junction is 0.25 mV at 5 K. The millimeter‐wave radiation is coupled to

  2. Millimeter-wave Radiometer for High Sensitivity Water Vapor Profiling in Arid Regions

    Energy Technology Data Exchange (ETDEWEB)

    Pazmany, Andrew

    2006-11-09

    Abstract - ProSensing Inc. has developed a G-band (183 GHz) water Vapor Radiometer (GVR) for long-term, unattended measurements of low concentrations of atmospheric water vapor and liquid water. Precipitable water vapor and liquid water path are estimated from zenith brightness temperatures measured from four double-sideband receiver channels, centered at 183.31 1, 3 and 7, and 14 GHz. A prototype ground-based version of the instrument was deployed at the DOE ARM program?s North Slope of Alaska site near Barrow AK in April 2005, where it collected data continuously for one year. A compact, airborne version of this instrument, packaged to operate from a standard 2-D PMS probe canister, has been tested on the ground and is scheduled for test flights in the summer of 2006. This paper presents design details, laboratory test results and examples of retrieved precipitable water vapor and liquid water path from measured brightness temperature data.

  3. Study the Effect of Using Low-Cost Dielectric Lenses with Printed Log-Periodic Dipole Antennas for Millimeter-Wave Applications

    Directory of Open Access Journals (Sweden)

    Osama M. Haraz

    2015-01-01

    Full Text Available Design of V-band high-gain printed log periodic dipole array (PLPDA antenna loaded with a low-cost spherical dielectric lens is introduced. The proposed antenna consists of microstrip-line-fed log-periodic dipole antenna designed to operate in the V-band with a peak gain of 12.64 dBi at 60 GHz. To enhance the antenna gain, a dielectric lens is installed. The antenna prototype is fabricated and then tested experimentally using Agilent E8364B PNA Network Analyzer. Experimental results agree well with the simulated ones. The simulated results show that the proposed antenna can work from 42 GHz up to 82 GHz with a fractional impedance bandwidth of 64.5% covering the whole V-band (50–75 GHz. At 60 GHz, the proposed antenna has peak gain of 26.79 dBi with a gain variation of 3.5 dBi across the whole V-band with stable radiation patterns over the operating band. The proposed PLPDA antenna achieves good side-lobe suppression, excellent front-to-back ratio in both E- and H-planes, and low cross-polarization levels over the entire frequency range. These unique features will make this antenna suitable for different interesting applications such as millimeter-wave radar and imaging applications.

  4. Millimeterwave Space Power Grid architecture development 2012

    Science.gov (United States)

    Komerath, Narayanan; Dessanti, Brendan; Shah, Shaan

    This is an update of the Space Power Grid architecture for space-based solar power with an improved design of the collector/converter link, the primary heater and the radiator of the active thermal control system. The Space Power Grid offers an evolutionary approach towards TeraWatt-level Space-based solar power. The use of millimeter wave frequencies (around 220GHz) and Low-Mid Earth Orbits shrinks the size of the space and ground infrastructure to manageable levels. In prior work we showed that using Brayton cycle conversion of solar power allows large economies of scale compared to the linear mass-power relationship of photovoltaic conversion. With high-temperature materials permitting 3600 K temperature in the primary heater, over 80 percent cycle efficiency was shown with a closed helium cycle for the 1GW converter satellite which formed the core element of the architecture. Work done since the last IEEE conference has shown that the use of waveguides incorporated into lighter-than-air antenna platforms, can overcome the difficulties in transmitting millimeter wave power through the moist, dense lower atmosphere. A graphene-based radiator design conservatively meets the mass budget for the waste heat rejection system needed for the compressor inlet temperature. Placing the ultralight Mirasol collectors in lower orbits overcomes the solar beam spot size problem of high-orbit collection. The architecture begins by establishing a power exchange with terrestrial renewable energy plants, creating an early revenue generation approach with low investment. The approach allows for technology development and demonstration of high power millimeter wave technology. A multinational experiment using the International Space Station and another power exchange satellite is proposed to gather required data and experience, thus reducing the technical and policy risks. The full-scale architecture deploys pairs of Mirasol sunlight collectors and Girasol 1 GW converter satellites t

  5. Monolithic watt-level millimeter-wave diode-grid frequency tripler array

    Science.gov (United States)

    Hwu, R. J.; Luhmann, N. C., Jr.; Rutledge, D. B.; Hancock, B.; Lieneweg, U.

    1988-01-01

    In order to provide watt-level CW output power throughout the millimeter and submillimeter wave region, thousands of solid-state diodes have been monolithically integrated using a metal grid to produce a highly efficient frequency multiplier. Devices considered include GaAs Schottky diodes, thin MOS diodes, and GaAs Barrier-Intrinsic-N(+)diodes. The performance of the present compact low-cost device has been theoretically and experimentally validated.

  6. Waveguide CP-FTMW and millimeter wave spectra of s-cis- and s-trans-acrylic acid

    Science.gov (United States)

    Alonso, E. R.; Kolesniková, L.; Peña, I.; Shipman, S. T.; Tercero, B.; Cernicharo, J.; Alonso, J. L.

    2015-10-01

    The millimeter wave spectrum of acrylic acid (CH2dbnd CHsbnd COOH), the simplest unsaturated carboxylic acid, was measured and analyzed from 130 to 360 GHz. Additional measurements from 18 to 26.5 GHz were also made using a waveguide CP-FTMW spectrometer. More than 4000 rotational lines were assigned to s-cis- and s-trans-acrylic acid in their ground vibrational states leading to precise determination of rotational, quartic and first complete set of sextic centrifugal distortion constants. New laboratory data of acrylic acid were then used to search for its spectral features in Orion KL, Sgr B2, and W51 molecular clouds. An upper limit to the column density of acrylic acid in Orion KL is provided.

  7. Millimeter wave surface resistance of grain-aligned Y1Ba2Cu3O(x) bulk material

    Science.gov (United States)

    Wosik, J.; Kranenburg, R. A.; Wolfe, J. C.; Selvamanickam, V.; Salama, K.

    1991-01-01

    Measurements of the millimeter wave surface resistance of grain-aligned YBa2Cu3O(x) bulk material grown by a liquid phase process are reported. The measurements were performed by replacing the endplate of a TE011 cylindrical copper cavity with the superconducting sample. Surface resistance was measured for samples with surfaces oriented perpendicular and parallel to the c-axis of the grains. It is shown that, for the parallel configuration, the surface resistance at 77 K and 80 GHz is typically near 100 milliohms. For a very well-aligned sample with a very low density of Y2BaCuO(y) precipitates, measured in the perpendicular configuration, the transition width (10-90 percent) is about 2 K, and the surface resistance is less than 50 milliohms at 88 K. The effect of microstructure on surface resistance is discussed.

  8. Dielectric properties of biocompatible and biodegradable polycaprolone and polylactide and their nanocomposites in the millimeter wave band

    Science.gov (United States)

    Kalenov, D. S.; Meriakri, V. V.; Parkhomenko, M. P.; Zhou, Sh.

    2012-07-01

    Complex dielectric permittivities of biocompatible, biodegradable and shape memory polycaprolon (PCL) and polyactide (PLA) composites with nanofillers in the form of multiwall carbon nanotubes (MWNTs) and Fe3O4 are investigated in the millimeter wave range in the temperature interval from 20 to 90°C in a. It is found that the electromagnetic-wave absorption in PCL and PLA, as well as in their nanocomposites, increases with temperature in the interval from 30°C to 45°C (PCL) and from 55°C to 90°C (PLA). The samples of PLA with MWNT prepared with melamine show much lower absorption compared with the same samples prepared without melamine

  9. Inspection of Spray on Foam Insulation (SOFI) Using Microwave and Millimeter Wave Synthetic Aperture Focusing and Holography

    Science.gov (United States)

    Case, J. T.; Hepburn, F. L.; Zoughi, R.

    2006-01-01

    The Space Shuttle Columbia s catastrophic failure is thought to have been caused by a dislodged piece of external tank spray on foam insulation (SOFI) striking and significantly damaging the left wing of the orbiter, which may have been due to a flawed section of SOFI. Microwave and millimeter wave nondestructive evaluation (NDE) methods have shown great potential detecting anomalies in SOFI such as small air voids using a horn and lens in a (real) focused configuration. Synthetic focusing methods may also be used to detect air voids in SOFI and may additionally offer the ability to locate the defect in three dimensions. To this end, two different methods were investigated; namely, frequency domain synthetic aperture focusing technique (FD-SAFT) and wide-band microwave holography. To illustrate the performance of these methods they were applied to two different SOFI samples. The results of these investigations demonstrate the capabilities of these methods for SOFI inspection.

  10. Measurement and simulation of ionic current as a means of quantifying effects of therapeutic millimeter wave radiation

    Science.gov (United States)

    Slovinsky, William Stanley

    A "millimeter wave" (MMW) is an electromagnetic oscillation with a wavelength between 1 and 10 mm, and a corresponding frequency of 30 to 300 GHz. In the spectrum of electromagnetic radiation, this band falls above the frequencies of radio waves and microwaves, and below that of infrared radiation. Since the 1950s, frequencies in this regime have been used for short range communications and beginning in the 1970s, a form of therapy known as "millimeter wave therapy" (MWT) , or microwave resonance therapy, in some publications. This form of therapy has been widely used in the republics of the former Soviet Union (FSU). As of 1995, it is estimated that more than one thousand medical centers in the FSU have performed MWT and more than three million patients have received this method of treatment. Despite the abundant use of this form of medicine, very little is known about the mechanisms by which it works. Early accounts of use are limited to Soviet government documents, largely unavailable to the scientific public, and limited translations and oral accounts from FSU scientists and literature reviews . This anecdotal body of evidence lacks the scrutiny of peer-reviewed journal publications. In order to gain more widespread acceptance in Western medicine, the pathway through which this regime of the electromagnetic radiation spectrum affects the human body must be rigorously mapped and quantified. Despite the anecdotal nature of a large portion of the existing research on biological MMW effects, a common link is the idea of an interaction occurring at the skin level, which is transduced into a signal used at a remote location in the body. This study explores a possible mechanism for the generation of this signal. The effects of therapeutic frequency MMW on the ionic currents through two different types of ion transport channels were studied, and the results are discussed with emphasis on how they relate to possible changes in nerve signals used by the body for

  11. Preliminary Study of a Millimeter Wave FMCW InSAR for UAS Indoor Navigation

    Directory of Open Access Journals (Sweden)

    Antonio F. Scannapieco

    2015-01-01

    Full Text Available Small autonomous unmanned aerial systems (UAS could be used for indoor inspection in emergency missions, such as damage assessment or the search for survivors in dangerous environments, e.g., power plants, underground railways, mines and industrial warehouses. Two basic functions are required to carry out these tasks, that is autonomous GPS-denied navigation with obstacle detection and high-resolution 3Dmapping with moving target detection. State-of-the-art sensors for UAS are very sensitive to environmental conditions and often fail in the case of poor visibility caused by dust, fog, smoke, flames or other factors that are met as nominal mission scenarios when operating indoors. This paper is a preliminary study concerning an innovative radar sensor based on the interferometric Synthetic Aperture Radar (SAR principle, which has the potential to satisfy stringent requirements set by indoor autonomous operation. An architectural solution based on a frequency-modulated continuous wave (FMCW scheme is proposed after a detailed analysis of existing compact and lightweight SAR. A preliminary system design is obtained, and the main imaging peculiarities of the novel sensor are discussed, demonstrating that high-resolution, high-quality observation of an assigned control volume can be achieved.

  12. Millimeter-wave silicon-based ultra-wideband automotive radar transceivers

    Science.gov (United States)

    Jain, Vipul

    circuits except the oscillators are shared between the two bands. A multi-functional injection-locked circuit is used after the oscillators to reconfigure the division ratio inside the phase-locked loop. The synthesizer is suitable for integration in automotive radar transceivers and heterodyne receivers for 94-GHz imaging applications. The transceiver chip includes a dual-band low noise amplifier, a shared downconversion chain, dual-band pulse formers, power amplifiers, a dual-band frequency synthesizer and a high-speed programmable baseband pulse generator. Radar functionality is demonstrated using loopback measurements.

  13. Detection of the Vibration Signal from Human Vocal Folds Using a 94-GHz Millimeter-Wave Radar

    Science.gov (United States)

    Chen, Fuming; Li, Sheng; Zhang, Yang; Wang, Jianqi

    2017-01-01

    The detection of the vibration signal from human vocal folds provides essential information for studying human phonation and diagnosing voice disorders. Doppler radar technology has enabled the noncontact measurement of the human-vocal-fold vibration. However, existing systems must be placed in close proximity to the human throat and detailed information may be lost because of the low operating frequency. In this paper, a long-distance detection method, involving the use of a 94-GHz millimeter-wave radar sensor, is proposed for detecting the vibration signals from human vocal folds. An algorithm that combines empirical mode decomposition (EMD) and the auto-correlation function (ACF) method is proposed for detecting the signal. First, the EMD method is employed to suppress the noise of the radar-detected signal. Further, the ratio of the energy and entropy is used to detect voice activity in the radar-detected signal, following which, a short-time ACF is employed to extract the vibration signal of the human vocal folds from the processed signal. For validating the method and assessing the performance of the radar system, a vibration measurement sensor and microphone system are additionally employed for comparison. The experimental results obtained from the spectrograms, the vibration frequency of the vocal folds, and coherence analysis demonstrate that the proposed method can effectively detect the vibration of human vocal folds from a long detection distance. PMID:28282892

  14. Radio Capacity Estimation for Millimeter Wave 5G Cellular Networks Using Narrow Beamwidth Antennas at the Base Stations

    Directory of Open Access Journals (Sweden)

    AlMuthanna Turki Nassar

    2015-01-01

    Full Text Available This paper presents radio frequency (RF capacity estimation for millimeter wave (mm-wave based fifth-generation (5G cellular networks using field-level simulations. It is shown that, by reducing antenna beamwidth from 65° to 30°, we can enhance the capacity of mm-wave cellular networks roughly by 3.0 times at a distance of 220 m from the base station (BS. This enhancement is far much higher than the corresponding enhancement of 1.2 times observed for 900 MHz and 2.6 GHz microwave networks at the same distance from the BS. Thus the use of narrow beamwidth transmitting antennas has more pronounced benefits in mm-wave networks. Deployment trials performed on an LTE TDD site operating on 2.6 GHz show that 6-sector site with 27° antenna beamwidth enhances the quality of service (QoS roughly by 40% and more than doubles the overall BS throughput (while enhancing the per sector throughput 1.1 times on average compared to a 3-sector site using 65° antenna beamwidth. This agrees well with our capacity simulations. Since mm-wave 5G networks will use arbitrary number of beams, with beamwidth much less than 30°, the capacity enhancement expected in 5G system when using narrow beamwidth antennas would be much more than three times observed in our simulations.

  15. Single-sideband W-band photonic vector millimeter-wave signal generation by one single I/Q modulator.

    Science.gov (United States)

    Li, Xinying; Xu, Yuming; Yu, Jianjun

    2016-09-15

    We propose a new scheme to generate single-sideband (SSB) photonic vector millimeter-wave (mm-wave) signal adopting asymmetrical SSB modulation enabled by a single in-phase/quadrature (I/Q) modulator. The driving signal for the I/Q modulator is generated by software-based digital signal processing (DSP) instead of a complicated transmitter electrical circuit, which significantly simplifies the system architecture and increases system stability. One vector-modulated optical sideband and one unmodulated optical sideband, with different sideband frequencies, located at two sides of a significantly suppressed central optical carrier, are generated by the I/Q modulator and used for heterodyne beating to generate the electrical vector mm-wave signal. The two optical sidebands are robust to fiber dispersion and can be transmitted over relatively long-haul fiber. We experimentally demonstrate the generation and transmission of 4-Gbaud 80-GHz quadrature-phase-shift-keying-modulated (QPSK-modulated) SSB vector mm-wave signal over 240-km single-mode fiber-28 without optical dispersion compensation.

  16. Millimeter wave surface resistance of RBa2Cu3O(7-delta) (R=Y,Eu,Dy,Sm,Er) superconductors

    Science.gov (United States)

    Miranda, F. A.; Gordon, W. L.; Eck, T. G.; Bhasin, K. B.; Warner, J. D.; Jenkins, K. A.

    1990-01-01

    The measurements are reported of the millimeter wave surface resistance R(sub s) at 58.6 GHz of bulk samples of RBa2Cu3O(7-delta) (R = Y,Eu,Dy,Sm,Er) and of YBa2Cu3O(7-delta) superconducting films, in the temperature range from 20 to 300 K. The bulk samples were prepared by cold pressing the powders of RBa2Cu3O(7-delta) into one in. disks. The powders were prepared by several sinterings in one atmosphere of oxygen at 925 C, with grindings between sinterings, to obtain the superconducting phase. The thin films were deposited on SrTiO3 and LaGaO3 substrates by pulsed laser ablation. Each sample was measured by replacing the end wall of a gold-plated Te sub 013 circular mode copper cavity with the sample and determining the cavity quality factor . From the difference in the Q-factor of the cavity, with and without the sample, the R(sub s) of the sample was determined.

  17. Detection of the Vibration Signal from Human Vocal Folds Using a 94-GHz Millimeter-Wave Radar

    Directory of Open Access Journals (Sweden)

    Fuming Chen

    2017-03-01

    Full Text Available The detection of the vibration signal from human vocal folds provides essential information for studying human phonation and diagnosing voice disorders. Doppler radar technology has enabled the noncontact measurement of the human-vocal-fold vibration. However, existing systems must be placed in close proximity to the human throat and detailed information may be lost because of the low operating frequency. In this paper, a long-distance detection method, involving the use of a 94-GHz millimeter-wave radar sensor, is proposed for detecting the vibration signals from human vocal folds. An algorithm that combines empirical mode decomposition (EMD and the auto-correlation function (ACF method is proposed for detecting the signal. First, the EMD method is employed to suppress the noise of the radar-detected signal. Further, the ratio of the energy and entropy is used to detect voice activity in the radar-detected signal, following which, a short-time ACF is employed to extract the vibration signal of the human vocal folds from the processed signal. For validating the method and assessing the performance of the radar system, a vibration measurement sensor and microphone system are additionally employed for comparison. The experimental results obtained from the spectrograms, the vibration frequency of the vocal folds, and coherence analysis demonstrate that the proposed method can effectively detect the vibration of human vocal folds from a long detection distance.

  18. Remote Cloud Sensing Intensive Observation Period (RCS-IOP) millimeter-wave radar calibration and data intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Sekelsky, S.M.; Firda, J.M.; McIntosh, R.E. [Univ. of Massachusetts, Amherst, MA (United States)] [and others

    1996-04-01

    During April 1994, the University of Massachusetts (UMass) and the Pennsylvania State University (Penn State) fielded two millimeter-wave atmospheric radars in the Atmospheric Radiation Measurement Remote Cloud Sensing Intensive Operation Period (RCS-IOP) experiment. The UMass Cloud Profiling Radar System (CPRS) operates simultaneously at 33.12 GHz and 94.92 GHz through a single antenna. The Penn State radar operates at 93.95 GHz and has separate transmitting and receiving antennas. The two systems were separated by approximately 75 meters and simultaneously observed a variety of cloud types at verticle incidence over the course of the experiment. This abstract presents some initial results from our calibration efforts. An absolute calibration of the UMass radar was made from radar measurements of a trihedral corner reflector, which has a known radar cross-section. A relative calibration of between the Penn State and UMass radars is made from the statistical comparison of zenith pointing measurements of low altitude liquid clouds. Attenuation is removed with the aid of radiosonde data, and the difference in the calibration between the UMass and Penn State radars is determined by comparing the ratio of 94-GHz and 95-GHz reflectivity values to a model that accounts for parallax effects of the two antennas used in the Penn State system.

  19. Proceedings SPIE: Conference Digest, International Conference on Infrared and Millimeter Waves (18th) Held in Colchester, United Kingdom on 6-10 September 1993. Volume 2104

    Science.gov (United States)

    1993-09-10

    RKlmmitt, Proceedings of the 16th International Conference on Infrared and Millimeter Waves, SPIE 1576, 548, (1991), [2) ADoria , O.PC3allerano, A.Renleri...axis and made of Ta and secondary cathode (SC) made of porous tungsten impregnated by barium aluminate, edged autoemitters, activated by barium, provide...two-beam polarisation configuration with tungsten wire grids as polarisers, analysers and beamdividers, as shown in figure 1. Collimated radiation

  20. X-Spec, A Multi-Object, Trans-Millimeter-Wave Spectrometer for CCAT

    OpenAIRE

    Bradford, C.M.; Hailey-Dunsheath, S.; Shirokoff, E.; Hollister, M.; Mckenney, C. M.; Leduc, H. G.; Reck, T.; Chapman, S.C.; Tikomirov, A.; Nikola, T.; Zmuidzinas, J.

    2014-01-01

    We present the result of a design study for X-Spec, a multi-beam, R=400-700 survey spectrometer covering 190-520 GHz under development for CCAT. It is designed to measure the bright atomic fine-structure and molecular rotational transitions that cool galaxies' interstellar gas, in particular, the 158 µm rest-frame [CII] transition, in thousands to tens of thousands of galaxies ranging from z=9 to z=3.5. With the wide bandwidth and multi-object capability, X-Spec / CCAT will be more powerful t...

  1. CSTI High Capacity Power

    Science.gov (United States)

    Winter, Jerry M.

    1989-01-01

    The SP-100 program was established in 1983 by DOD, DOE, and NASA as a joint program to develop the technology necessary for space nuclear power systems for military and civil application. During FY-86 and 87, the NASA SP-100 Advanced Technology Program was devised to maintain the momentum of promising technology advancement efforts started during Phase 1 of SP-100 and to strengthen, in key areas, the chances for successful development and growth capability of space nuclear reactor power systems for future space applications. In FY-88, the Advanced Technology Program was incorporated into NASA's new Civil Space Technology Initiative (CSTI). The CSTI Program was established to provide the foundation for technology development in automation and robotics, information, propulsion, and power. The CSTI High Capacity Power Program builds on the technology efforts of the SP-100 program, incorporates the previous NASA SP-100 Advanced Technology project, and provides a bridge to NASA Project Pathfinder. The elements of CSTI High Capacity Power development include Conversion Systems, Thermal Management, Power Management, System Diagnostics, and Environmental Interactions. Technology advancement in all areas, including materials, is required to assure the high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems. The overall program will develop and demonstrate the technology base required to provide a wide range of modular power systems as well as allowing mission independence from solar and orbital attitude requirements. Several recent advancements in CSTI High Capacity power development will be discussed.

  2. Control of the deformation for the millimeter wave range radiotelescope mirrors

    Science.gov (United States)

    Konyakhin, Igor; Artemenko, Yury; Timofeev, Aleksandr

    2008-10-01

    The mirror construction of the radiotelescope for millimetre wave range requires to measure the line deformation of mirror's surface. Now the control system is based on the trilateration method and it uses three laser distance-meters. This type of the measuring system can't be used for new radio-telescope RT-70 (Suffa). Following issues dealing with this problem are described in this article: 1) the possibility of the design of deformation measurement system based on triangular method 2) the new scheme of optic-electronic measurement system. The great attention during the research was paid to the experimental approval of the theoretical results. The model of the described system had the following characteristics: infrared emission diode AL107B by power 15 mWt as sources of radiation; the objective by the focal length 405 mm as aperture of receiver video-camera, the CMOS matrix receiver by type OV05610 Color CMOS QSXGA with 2592*1944 pixels and one pixel size (2.8*2.8) μm2 produced OmniVision as image analyzer . The computer simulation error and the experimental error measurement was 0.05 mm at the range 30 mm on a working distance 25 m, that allows to measure the deformation of radiotelescope construction with the mirror diameter 70 m.

  3. Silicon photonics-wireless interface ICs for micro-/millimeter-wave fiber-wireless networks.

    Science.gov (United States)

    Ko, Minsu; Lee, Myung-Jae; Rücker, Holger; Choi, Woo-Young

    2013-09-23

    We present two types of Si photonics-wireless interface (PWI) integrated circuits (ICs) realized in standard Si technology. Our PWI ICs convert optical signals into radio-frequency (RF) signals for downlink remote antenna units in fiber-wireless networks. Characterization and modeling of Si avalanche photodetectors (APDs) fabricated in two different Si technologies are carried out and used for PWI IC design. A 5-GHz RF-over-fiber PWI IC composed of APD, preamplifier, and power amplifier (PA) is fabricated in 0.18-μm CMOS technology and its performance is verified by 54-Mb/s wireless local area network data transmission. A 60-GHz baseband-over-fiber PWI IC containing APD, baseband photoreceiver, 60-GHz binary phase-shift keying (BPSK) modulator, and 60-GHz PA is realized in 0.25-μm SiGe BiCMOS technology. Error-free transmission of 1.6-Gb/s BPSK data in 60 GHz with this PWI IC is successfully achieved.

  4. A large-diameter hollow-shaft cryogenic motor based on a superconducting magnetic bearing for millimeter-wave polarimetry

    Science.gov (United States)

    Johnson, B. R.; Columbro, F.; Araujo, D.; Limon, M.; Smiley, B.; Jones, G.; Reichborn-Kjennerud, B.; Miller, A.; Gupta, S.

    2017-10-01

    In this paper, we present the design and measured performance of a novel cryogenic motor based on a superconducting magnetic bearing (SMB). The motor is tailored for use in millimeter-wave half-wave plate (HWP) polarimeters, where a HWP is rapidly rotated in front of a polarization analyzer or polarization-sensitive detector. This polarimetry technique is commonly used in cosmic microwave background polarization studies. The SMB we use is composed of fourteen yttrium barium copper oxide (YBCO) disks and a contiguous neodymium iron boron (NdFeB) ring magnet. The motor is a hollow-shaft motor because the HWP is ultimately installed in the rotor. The motor presented here has a 100 mm diameter rotor aperture. However, the design can be scaled up to rotor aperture diameters of approximately 500 mm. Our motor system is composed of four primary subsystems: (i) the rotor assembly, which includes the NdFeB ring magnet, (ii) the stator assembly, which includes the YBCO disks, (iii) an incremental encoder, and (iv) the drive electronics. While the YBCO is cooling through its superconducting transition, the rotor is held above the stator by a novel hold and release mechanism. The encoder subsystem consists of a custom-built encoder disk read out by two fiber optic readout sensors. For the demonstration described in this paper, we ran the motor at 50 K and tested rotation frequencies up to approximately 10 Hz. The feedback system was able to stabilize the rotation speed to approximately 0.4%, and the measured rotor orientation angle uncertainty is less than 0.15°. Lower temperature operation will require additional development activities, which we will discuss.

  5. Super-resolution image reconstruction applied to an active millimeter wave imaging system based on compressive sensing

    Science.gov (United States)

    Alkuş, Ümit; Şengün Ermeydan, Esra; Şahin, Asaf Behzat; ćankaya, Ä.°lyas; Altan, Hakan

    2017-10-01

    The development of passive and active millimeter wave imaging systems is progressing rapidly fueled by the need for many applications in the area of security and defense. Imaging schemes that may either utilize array detectors or single detectors in scan architectures offer suffer from poor resolution due to the longer wavelengths used and the limits of the optical system in terms of lens and mirror dimensions. In order to overcome this limit, super-resolution techniques can be employed to enhance the resolution of the imaging system. Here, a form of this technique based on oversampling is applied to reconstruct the image of a target which is acquired using compressive sensing based on scanning the image plane using randomly patterned masks with fixed pixel sizes. The mm-wave stand-off imaging system uses a 93 GHz center frequency source and heterodyne sub-harmonic receiver place in a bi-static configuration to image a target in reflection mode. The image of the target is projected onto a mechanically scanned spatial light modulator (SLM), which is a patterned two-dimensional mask that is translated along one axis. In order to improve the resolution of the image, the masks are shifted by half the pixel size (2.5mm). To enhance the resolution of the image, the patterns are shifted by smaller steps, thereby each pixel is oversampled and the resulting new pattern and detected intensity is fed into the CS algorithm to reconstruct the image of the target. After the image reconstruction process, sharper edges are observed for a circular object of 12mm diameter compared to the image acquired by whole pixel step scanning.

  6. Remote Effects of Electromagnetic Millimeter Waves on Experimentally Induced Cold Pain: A Double-Blinded Crossover Investigation in Healthy Volunteers.

    Science.gov (United States)

    Partyla, Tomasz; Hacker, Henriette; Edinger, Hardy; Leutzow, Bianca; Lange, Joern; Usichenko, Taras

    2017-03-01

    The hypoalgesic effect of electromagnetic millimeter waves (MW) is well studied in animal model; however, the results of human research are controversial. The aim of this study was to evaluate the effects of various frequency ranges of MW on hypoalgesia using the cold pressor test (CPT). Experimental pain was induced using standardized CPT protocols in 20 healthy male volunteers. The skin of the lower part of sternum was exposed to MW with a frequency of 42.25 GHz (active generator); MW within 50-75 GHz frequency range (noise generator); or an inactive MW device (placebo generator) in a random crossover double-blinded manner. Pain threshold, measured using the CPT, was the primary outcome. Other CPT parameters, heart rate, blood pressure, incidence of subjective sensations (paresthesia) during exposure, as well as quality of volunteers' blinding were also recorded. The end points of the condition with exposure to 42.25 GHz, were compared with baseline; exposure to noise 50-75 GHz; and placebo generators. Pain threshold increased during exposure to the 42.25 GHz generator when compared with baseline: median difference (MD), 1.97 seconds (95% confidence interval [CI], 0.35-3.73) and noise generator: MD, 1.27 seconds (95% CI, 0.05-2.33) but not compared with the placebo generator. Time to onset of cold and increasing pain sensations as well as diastolic blood pressure increased under the exposure to the 42.25 GHz generator when compared with baseline and noise generator. Other outcome measures were comparable among the study conditions. We were able to partially confirm the previously suggested hypoalgesic effects of low-intensity electromagnetic MW. However, the effect was indistinguishable from the placebo condition in our investigation.

  7. Microcontroller-based binary integrator for millimeter-wave radar experiments.

    Science.gov (United States)

    Eskelinen, Pekka; Ruoskanen, Jukka; Peltonen, Jouni

    2010-05-01

    An easily on-site reconfigurable multiple binary integrator for millimeter radar experiments has been constructed of static random access memories, an eight bit microcontroller, and high speed video operational amplifiers. The design uses a raw comparator path and two adjustable m-out-of-n chains in a wired-OR configuration. Standard high speed memories allow the use of pulse widths below 100 ns. For eight pulse repetition intervals it gives a maximum improvement of 6.6 dB for stationary low-level target echoes. The doubled configuration enhances the capability against fluctuating targets. Because of the raw comparator path, also single return pulses of relatively high amplitude are processed.

  8. High Power Vanadate lasers

    CSIR Research Space (South Africa)

    Strauss, HJ

    2006-07-01

    Full Text Available This presentation aims at the following: to develop new techniques to mount laser crystals; compare the laser properties of two equally doped, high power Nd:YVO4 and Nd: GdVO4 lasers; build a 1um vanadate laser with average output power exceeding...

  9. Transport in Heterostructures and Device in Microwave and Millimeter Wave Regimes

    Science.gov (United States)

    1992-03-31

    InGaAs detectors for the communications wavelengths of 1.3 and 1.5 jim will be made soon. 6) We have generated, for the first time, kilovolt...support of the tasks described above. Tecnology 1) We will continue our investigation of low-temperature-grown semiconductors applied as high

  10. Near-Millimeter Wave Technology Base Study: Volume I. Propagation and Target/Background Characteristics

    Science.gov (United States)

    1979-11-01

    iuon Due to Water Vapor im the Frequency Band 15I-700 Gilt ,IE•ETras, M¢•oav•Theory and T,,chnlm~uea, v~ol. MTT.25, no, S (lull# 1977), 48(.486. "R. 1...Details on samplers and replicators t feedback circuitry, resulting in high reliability, are given by Spyors-Duran.’ ,:•: infrequent need for

  11. Millimeter-wave soldier-to-soldier communications for covert battlefield operations

    NARCIS (Netherlands)

    Cotton, Simon L.; Scanlon, W.G.; Madahar, Bhopinder K.

    2009-01-01

    Mobile ad hoc networking of dismounted combat personnel is expected to play an important role in the future of network-centric operations. High-speed, short-range, soldier-to-soldier wireless communications will be required to relay information on situational awareness, tactical instructions, and

  12. On the Accurate Modeling of Millimeter Wave Fixed Wireless Channels Exceedance Probability

    Science.gov (United States)

    Georgiadou, E. M.; Panagopoulos, A. D.; Chatzarakis, G. E.; Kanellopoulos, J. D.

    2006-07-01

    The ever increasing demand for high date rate multimedia services has led to the deployment of Fixed Wireless Access (FWA) networks operating in frequencies above 10GHz. Propagation characteristics of such networks include line-of-sight (LOS) transmissions highly influenced by the presence of rain. In this paper a methodology for evaluating the outage probability of a FWA channel is introduced, making use of the forward scattering amplitude by distorted raindrops of transmitted signals. Expressions for the imaginary part of the scattering amplitude are derived through a regression fitting analysis on the results of the Method of Auxiliary Sources (MAS) to the problem of electromagnetic scattering from a Pruppacher-Pitter raindrop. These expressions are employed and an analytical method to evaluate the rain attenuation exceedance probability over a fixed wireless access link is presented. The derived exceedance probabilities are compared with experimental data from ITU-R databank with encouraging results.

  13. Novel On Chip Passive Circuits for RF, Microwave, Millimeter wave and Sub THz Applicatons

    Science.gov (United States)

    2015-07-01

    linearity and high-Q are achieved, simultaneously. V. HYBRID SUB-THz CPW /DGS REsONATOR On-chip sub-THz application is a hot-research topic in... resonator with dual- resonances remains a great challenge. In Fig. 9, a hybrid CPW /DGS resonator [12) is proposed, which is with one-side directly...paper. Several types passive including SSI inductor, SSI transformer, 30 self-shielded capacitor, and hybrid sub-THz CPW /DGS resonator are

  14. Investigation of Hexagonal Ferrite Film Growth Techniques for Millimeter-Wave Systems Applications.

    Science.gov (United States)

    1987-03-15

    made on samples of Ba3 (V04)2 ; Table 5 presents the results of the determination. The magnetization is lower than that of gadolinium gallium garnet...these liosseser. a better lattice parameter match is rain sarcnt high melting point materials, (sapphire. required %ri uii aluminum garnet, gadolinium ...of gadolinium gallium garnet (+49 G), which is the standard substrate for yttrium iron garnet film growth. However, the dielectric constant is

  15. Millimeter-wave passive ultra-compact imaging technology for synthetic vision & mobile platforms

    Science.gov (United States)

    Olsen, Randall

    1996-01-01

    Substantial technical progress was made on all of the three high-risk subsystems of this program. The subsystems include dielectric antenna, G-band receiver, and electro-optic image processor. Progress is approximately on-schedule for both the receiver and the electro-optic processor development, while greater than anticipated challenges have been discovered in the dielectric antenna development. Much of the information in this report was covered in greater detail in the One-Year Review Meeting held at TTC on 22 February 1996. The performance goals of the dielectric antenna project are: Scan Angle -- 20 deg. desired; Loss -- 6 dB end to end (3 dB average); Frequency -- 206-218 GHz (6% bandwidth); Beam width -- 0.25 deg.; and Length -- 12 inches. The scan angle requirement was chosen to satisfy the needs of aircraft pilots. This requirement, coupled with the presently limited bandwidth processors (1 GHz state-of-the-art and 12 GHz in development in this program) forces the antenna to be dielectric (high scan angle air-filled waveguide-based antennas would be too lossy and their performance would vary too much as a function of frequency). A high dielectric constant (e.g., 10) was initially chosen for the dielectric material. This choice lead to the following fabrication challenges: total thickness variation (TTV) tolerance is 1 micrometer; coupler spacing tolerance is 1 micrometer; width tolerance is larger, but unknown, and the surfaces must have mirror finish. Also of importance is the difficulty in obtaining raw materials that satisfy the overall length requirement of 12 inches while simultaneously satisfying the above specifications.

  16. Scattering of millimeter waves by snow crystals and equivalent homogeneous symmetric particles.

    Science.gov (United States)

    O'Brien, S G; Goedecke, G H

    1988-06-15

    The digitized Green's function code was used to compute differential and total cross sections of several model snow crystals and of several homogeneous highly symmetric equivalent particles of the same general shape and size as the snow crystals at a wavelength of 10 mm. Optical constants of equivalent particles were derived using the Biot-Arago, Lorentz-Lorenz, and Bruggemann mixing rules. Reasonable agreement was found for equivalent particles whose mass distributions were most similar to those of the snow crystals. Overall, the Bruggemann mixing rule produced the best match.

  17. Bias-Voltage-Dependent Subcircuit Model for Millimeter-Wave CMOS Circuit

    Science.gov (United States)

    Katayama, Kosuke; Motoyoshi, Mizuki; Takano, Kyoya; Fujimoto, Ryuichi; Fujishima, Minoru

    In this paper, we propose a new method for the bias-dependent parameter extraction of a MOSFET, which covers DC to over 100GHz. The DC MOSFET model provided by the chip foundry is assumed to be correct, and the core DC characteristics are designed to be asymptotically recovered at low frequencies. This is carried out by representing the corrections required at high frequencies using a bias-dependent Y matrix, assuming that a parasitic nonlinear two-port matrix (Y-wrapper) is connected in parallel with the core MOSFET. The Y-wrapper can also handle the nonreciprocity of the parasitic components, that is, the asymmetry of the Y matrix. The reliability of the Y-wrapper model is confirmed through the simulation and measurement of a one-stage common-source amplifier operating at several bias points. This paper will not discuss about non-linearity.

  18. Sub-millimeter-Wave Equivalent Circuit Model for External Parasitics in Double-Finger HEMT Topologies

    Science.gov (United States)

    Karisan, Yasir; Caglayan, Cosan; Sertel, Kubilay

    2018-02-01

    We present a novel distributed equivalent circuit that incorporates a three-way-coupled transmission line to accurately capture the external parasitics of double-finger high electron mobility transistor (HEMT) topologies up to 750 GHz. A six-step systematic parameter extraction procedure is used to determine the equivalent circuit elements for a representative device layout. The accuracy of the proposed approach is validated in the 90-750 GHz band through comparisons between measured data (via non-contact probing) and full-wave simulations, as well as the equivalent circuit response. Subsequently, a semi-distributed active device model is incorporated into the proposed parasitic circuit to demonstrate that the three-way-coupled transmission line model effectively predicts the adverse effect of parasitic components on the sub-mmW performance in an amplifier setting.

  19. Millimeter-wave imaging of magnetic fusion plasmas: technology innovations advancing physics understanding

    Science.gov (United States)

    Wang, Y.; Tobias, B.; Chang, Y.-T.; Yu, J.-H.; Li, M.; Hu, F.; Chen, M.; Mamidanna, M.; Phan, T.; Pham, A.-V.; Gu, J.; Liu, X.; Zhu, Y.; Domier, C. W.; Shi, L.; Valeo, E.; Kramer, G. J.; Kuwahara, D.; Nagayama, Y.; Mase, A.; Luhmann, N. C., Jr.

    2017-07-01

    Electron cyclotron emission (ECE) imaging is a passive radiometric technique that measures electron temperature fluctuations; and microwave imaging reflectometry (MIR) is an active radar imaging technique that measures electron density fluctuations. Microwave imaging diagnostic instruments employing these techniques have made important contributions to fusion science and have been adopted at major fusion facilities worldwide including DIII-D, EAST, ASDEX Upgrade, HL-2A, KSTAR, LHD, and J-TEXT. In this paper, we describe the development status of three major technological advancements: custom mm-wave integrated circuits (ICs), digital beamforming (DBF), and synthetic diagnostic modeling (SDM). These have the potential to greatly advance microwave fusion plasma imaging, enabling compact and low-noise transceiver systems with real-time, fast tracking ability to address critical fusion physics issues, including ELM suppression and disruptions in the ITER baseline scenario, naturally ELM-free states such as QH-mode, and energetic particle confinement (i.e. Alfvén eigenmode stability) in high-performance regimes that include steady-state and advanced tokamak scenarios. Furthermore, these systems are fully compatible with today’s most challenging non-inductive heating and current drive systems and capable of operating in harsh environments, making them the ideal approach for diagnosing long-pulse and steady-state tokamaks.

  20. New movable plate for efficient millimeter wave vertical on-chip antenna

    KAUST Repository

    Marnat, Loic

    2013-04-01

    A new movable plate concept is presented in this paper to realize mm-wave vertical on-chip antennas through MEMS based post-processing steps in a CMOS compatible process. By virtue of its vertical position, the antenna is isolated from the lossy Si substrate and hence performs with a better efficiency as compared to the horizontal position. In addition, the movable plate concept enables polarization diversity by providing both horizontal and vertical polarizations on the same chip. Through a first iteration fractal bowtie antenna design, dual band (60 and 77 GHz) operation is demonstrated in both horizontal and vertical positions without any change in dimensions or use of switches for two different mediums (Si and air). To support the movable plate concept, the transmission line and antenna are designed on a flexible polyamide, where the former has been optimized to operate in the bent position. The design is highly suitable for compact, low cost and efficient SoC solutions. © 1963-2012 IEEE.

  1. High Power Electronics

    Science.gov (United States)

    Pendharker, Sameer

    High Power Electronics Future Trends: New process, circuit and packaging technologies over the last 5 years have led to significant innovation and technological developments in high power electronics. In this topic, the trends and performance improvements achieved in the industry will be discussed with focus on gallium-nitride (GaN) and silicon carbide (SiC). Both GaN and SiC technologies have been around for many years but have seen limited adoption and proliferation in high power systems. With the improved transistor performance, power conversion efficiencies and densities previously unrealizable are now available leading to new applications and new system. Trends in these technologies will also be reviewed and remaining challenges to overcome before true mass market adoption can be expected.

  2. Design, Analysis, and Characterization of Metamaterial Quasi-Optical Components for Millimeter-Wave Automotive Radar

    Science.gov (United States)

    Nguyen, Vinh Ngoc

    Since their introduction by Mercedes Benz in the late 1990s, W-band radars operating at 76-77 GHz have found their way into more and more passenger cars. These automotive radars are typically used in adaptive cruise control, pre-collision sensing, and other driver assistance systems. While these systems are usually only about the size of two stacked cigarette packs, system size, and weight remains a concern for many automotive manufacturers. In this dissertation, I discuss how artificially structured metamaterials can be used to improve lens-based automotive radar systems. Metamaterials allow the fabrication of smaller and lighter systems, while still meeting the frequency, high gain, and cost requirements of this application. In particular, I focus on the development of planar artificial dielectric lenses suitable for use in place of the injection-molded lenses now used in many automotive radar systems. I begin by using analytic and numerical ray-tracing to compare the performance of planar metamaterial GRIN lenses to equivalent aspheric refractive lenses. I do this to determine whether metamaterials are best employed in GRIN or refractive automotive radar lenses. Through this study I find that planar GRIN lenses with the large refractive index ranges enabled by metamaterials have approximately optically equivalent performance to equivalent refractive lenses for fields of view approaching +/-20°. I also find that the uniaxial nature of most planar metamaterials does not negatively impact planar GRIN lens performance. I then turn my attention to implementing these planar GRIN lenses at W-band automotive radar frequencies. I begin by designing uniform sheets of W-band electrically-coupled LC resonator-based metamaterials. These metamaterial samples were fabricated by the Jokerst research group on glass and liquid crystal polymer (LCP) substrates and tested at Toyota Research Institute- North America (TRI-NA). When characterized at W-band frequencies, these

  3. Four criteria to find an optimal location in Colombia for a millimeter wave astronomical observatory

    Science.gov (United States)

    Ramírez Suárez, O. L.; Martínez Mercado, A. M.; Restrepo Gaitán, O. A.; Chaparro Molano, G.

    2017-07-01

    To find an optimal location for a mm-wave astronomical observatory, all factors that directly or indirectly affect the water vapor column density should be considered. After estimating a weighted classification of these factors to obtain a range of acceptable values, places satisfying as many of these suitability conditions can be proposed as candidates. Here we analyze data from NASA and IDEAM to find places satisfying the best conditions to build a mm-wave astronomical observatory in Colombia, according to seven variables grouped into four classes. From NASA, we analyze the satellite data of: (i) relative humidity and (ii) cloud coverage/direct normal radiation, averaged monthly from 1983 to 2005. From IDEAM, we analyze data of relative humidity, sunshine, and (iii) precipitation/number of days with rain, averaged yearly over each month from 1981 to 2010. The data has been obtained in-situ by 2046 weather monitoring stations across Colombia, for which their (iv) altitude is known. For each quantity, we do a Principal Component Analysis, reducing the dimensionality of the yearly-averaged data to 2 components covering >90% of the variance. After this, we make a classification of the reduced-dimension data using a 4 cluster Gaussian Mixture Model (GMM), identifying similar geographic and climatological patterns. After selecting clusters of stations sharing optimal conditions (i.e. high altitude, low rain, etc.), we group and look for geographical clusters by applying a GMM on a Monte Carlo sampling of latitude, longitude, and altitude data in order to correct for biases. This method allows us to find regions of interest where further in-situ measurements of atmospheric absorption of mm-wave should be carried out in the future.

  4. Millimeter-Wave Spectroscopy of Formyl Azide (HC(O)N_3)

    Science.gov (United States)

    Walters, Nicholas A.; Amberger, Brent K.; Esselman, Brian J.; Woods, R. Claude; McMahon, Robert J.

    2015-06-01

    Formyl azide (HC(O)N_3) is a highly unstable molecule (t1/2˜2 hours at room temperature as a gas) that has only recently been studied spectroscopically by UV, IR, Raman and NMR methods. We have synthesized formyl azide and obtained its absorption spectrum at room temperature over the range 250-360 GHz. As in the case of carbonyl diazide, two conformers are expected for HC(O)N_3, with the syn-isomer 2.8 kcal/mol lower in energy than the anti-isomer (CCSD(T)/ANO1). Calculations at the same level of theory and the same basis set predict the dipole moments for the syn-isomer (μ = 1.56 D) and anti-isomer (μ = 2.56 D). These calculations also indicate that b-type transitions should dominate the syn-isomer spectrum, while a-type transitions become more significant in the case of the anti-isomer. Despite the anti-isomer having a larger dipole moment, the syn-isomer still gives rise to all the dominant features of the spectrum. Thus far, five vibrational states (νb{9}, νb{12}, 2νb{9}, νb{9} + νb{12}, νb{11}) have been studied for the syn-isomer, with the highest energy state νb{11} = 582.6 wn. Searches for the spectra of the anti-isomer are ongoing. Banert, K. et al. Angew. Chem. Int. Ed. 2012, 51, 4718-4721 Zeng, X. et al. Angew. Chem. Int. Ed. 2013, 52, 3503-3506 Amberger, B.K. et al. J. Mol. Spectrosc. 259, (2014) 15-20

  5. Solar Flash Sub-Millimeter Wave Range Spectrum Part Radiation Modeling

    Directory of Open Access Journals (Sweden)

    V. Yu. Shustikov

    2015-01-01

    Full Text Available Currently, solar flares are under observation on the RT-7.5 radio telescope of BMSTU. This telescope operates in a little-studied range of the spectrum, at wavelengths of 3.2 and 2.2 mm (93 and 140 GHz, thereby providing unique information about parameters of the chromosphere plasma and zone of the temperature minimum. Observations on various instruments provided relatively small amount of data on the radio emission flare at frequencies close to 93 GHz, and at frequency of 140 GHz such observations were not carried out. For these reasons, data collected from the RT-7.5 radio telescope are of high value (Shustikov et al., 2012.This work describes modeling and gives interpretation of the reason for raising flux density spectrum of sub-millimeter radio frequency emission using as an example the GOES flare of class M 5.3 occurred on 04.07.2012 in the active region 11515. This flare was observed on the RT-7.5 radio telescope of BMSTU and was described by Shustikov et al. (2012 and by Smirnova et al. (2013, where it has been suggested that the reason for raising radio frequency emission is a bremsstrahlung of the thermal electrons in the hot plasma of the solar chromosphere. Rough estimates of the plasma temperature at the flare source were obtained.This paper proposes model calculations of the flux density spectrum of the sub-millimeter radio emission based on the gyrosynchrotron Fleischman-Kuznetsov code (Fleishman & Kuznetsov, 2010. Section 1 briefly describes observational data, tools and processing methods used in the work. Section 2 shows results of modeling the flare radio emission. Section 3 discusses results and conclusions.Numerical modeling the sub-millimeter part of the spectrum of the radio flux density for the GOES flare of class M5.3 has been carried out. This flare occurred in the active region 11515 on 04.07.2012. Modeling was based on the observations on the BMSTU’s RT-7.5 radio telescope.The paper draws conclusion based on the

  6. Resonant High Power Combiners

    CERN Document Server

    Langlois, Michel; Peillex-Delphe, Guy

    2005-01-01

    Particle accelerators need radio frequency sources. Above 300 MHz, the amplifiers mostly used high power klystrons developed for this sole purpose. As for military equipment, users are drawn to buy "off the shelf" components rather than dedicated devices. IOTs have replaced most klystrons in TV transmitters and find their way in particle accelerators. They are less bulky, easier to replace, more efficient at reduced power. They are also far less powerful. What is the benefit of very compact sources if huge 3 dB couplers are needed to combine the power? To alleviate this drawback, we investigated a resonant combiner, operating in TM010 mode, able to combine 3 to 5 IOTs. Our IOTs being able to deliver 80 kW C.W. apiece, combined power would reach 400 kW minus the minor insertion loss. Values for matching and insertion loss are given. The behavior of the system in case of IOT failure is analyzed.

  7. On-Chip Power-Combining for High-Power Schottky Diode Based Frequency Multipliers

    Science.gov (United States)

    Siles Perez, Jose Vicente (Inventor); Chattopadhyay, Goutam (Inventor); Lee, Choonsup (Inventor); Schlecht, Erich T. (Inventor); Jung-Kubiak, Cecile D. (Inventor); Mehdi, Imran (Inventor)

    2015-01-01

    A novel MMIC on-chip power-combined frequency multiplier device and a method of fabricating the same, comprising two or more multiplying structures integrated on a single chip, wherein each of the integrated multiplying structures are electrically identical and each of the multiplying structures include one input antenna (E-probe) for receiving an input signal in the millimeter-wave, submillimeter-wave or terahertz frequency range inputted on the chip, a stripline based input matching network electrically connecting the input antennas to two or more Schottky diodes in a balanced configuration, two or more Schottky diodes that are used as nonlinear semiconductor devices to generate harmonics out of the input signal and produce the multiplied output signal, stripline based output matching networks for transmitting the output signal from the Schottky diodes to an output antenna, and an output antenna (E-probe) for transmitting the output signal off the chip into the output waveguide transmission line.

  8. Millimeter Wave Communications

    Science.gov (United States)

    1984-06-01

    64 64:7 34OF9 043 64 ?~ 4’ ’ J "IN0󈨀 ŗ 34 69044137 Saw a.? 64 3 3 6 N @6’ 4’ ) IF6 1.41 W i V ature will give values to be expected (Reference 9: 322...Octooer 1978, the Atmospheric Sciences Laboratories c’nducted a malor test called DIRT-I, to obtain direct sensor information about the properties of dust...wave frequencies (2.15) D where G v Antenna gain a Wavelength in meters c = Speed of light - 3.0 x 10meterslsecond f a Frequency in Hertz A

  9. Changes of mouse cytokines and Th1/Th2 balance in acute stress induced by millimeter-wave

    Directory of Open Access Journals (Sweden)

    Rong SUN

    2013-11-01

    Full Text Available Objective To explore the regular pattern of variation of cytokines, especially the Th1/Th2 cytokines, and its effect on immune balance in stress induced by 35GHz millimeter-wave (MMW exposure in mice. Methods BALB/c mice were exposed to 420mW/cm2, 35GHz MMW for 60s, and the dorsal skin temperature was real-time monitored with infrared monitor during the period of exposure. Peripheral WBC, thymic and splenic indexes of mice were detected at different time points after MMW exposure. Meanwhile, the contents of serum IL-1β, IL-2, IL-6 and Th1/Th2 cytokines IFN-γ, IL-4 were analyzed by ELISA. Results The temperature of ear auricle rapidly increased to 50℃ after initiation of exposure, and continuously rose to about 60℃ at 50s to 60s. Peripheral WBC and lymphocytes showed transient reduction at 6h and restored to the control level from 1 to 7d after radiation exposure. Compared with control group, thymus index displayed a transient increase at 6h and thereafter decreased, and then diminished to which significantly lower than control level 7d after radiation exposure. However, spleen index increased significantly on day 3 and day 7 after radiation exposure. Peripheral IL-1β levels immediately increased to the maximum at 6h and decreased to the minimum at 1d (P<0.05, then gradually recovered to control level during 3d and 7d after radiation exposure. However, IL-6 level displayed a significant increment from 6h to 3d, and increased to peak value at 1d and still obviously higher than that of control group up to 7d (P<0.05 after radiation exposure. Simultaneously, Th1/Th2 cytokines IFN-γ and IL-4 both increased to the maximal at 3d and still significantly higher than those of control group at 7d (P<0.01 after radiation exposure. Ratios of Th1/Th2 (IFN-γ/IL-4 evidently raised to 1.34 and 1.66 times of control values at 1d and 3d respectively (P<0.05. Conclusions 35GHz MMW exposure can induce obvious thermal effects in mice, and serum

  10. Effects of acute millimeter wave exposure on the expression of substance P and c-fos in rat spinal cord

    Directory of Open Access Journals (Sweden)

    Yan-wen ZHANG

    2013-04-01

    Full Text Available Objective  To observe the expression changes in substance P (SP and c-fos in rat spinal cord after acute millimeter-wave (MMW exposure, and explore the mechanism of thermal hyperalgesia at the spinal level. Methods  The back skin of SD rats was exposed to 35 GHz MMW (40W/cm2 for 0s (control group, 30s, 1min, or 3min. The corresponding segment of the spinal cord was taken at 0min, 5min, 10min, 1h and 3h after MMW irradiation for total RNA and protein extraction. The expressions of SP and c-fos mRNA were measured by real-time RT-PCR, and the expression of c-fos protein was detected by Western blotting. Results  No significant difference was found between the control group and irradiation groups in SP and c-fos mRNA expression in the corresponding segment of spinal cord after MMW irradiation for 30s. After MMW irradiation for 1min, the SP and c-fos mRNA expressions in the corresponding segment of spinal cord increased significantly at 10min time point, and then decreased to the level of control group. After MMW irradiation for 3min, the SP and c-fos mRNA expression in the corresponding segment of spinal cord increased significantly at 5min, 10min and 1h time points, and decreased to the level of control group at 3h. No significant change was found in c-fos protein expression in the corresponding segment of spinal cord after MMW irradiation for 30s and 1min. After MMW irradiation for 3min, the c-fos protein expression in the corresponding segment of spinal cord increased significantly at 5min and 10min time point, and then decreased to the level of control group. Conclusion  The increase of SP expression in rat skin after MMW irradiation may be related to the increase of SP and c-fos expressions in the corresponding segment of the spinal cord induced by thermal pain stimulation.

  11. Rapid Sintering of Silica Xerogel Ceramic Derived from Sago Waste Ash Using Sub-millimeter Wave Heating with a 300 GHz CW Gyrotron

    Science.gov (United States)

    Aripin, Haji; Mitsudo, Seitaro; Sudiana, I. Nyoman; Tani, Shinji; Sako, Katsuhide; Fujii, Yutaka; Saito, Teruo; Idehara, Toshitaka; Sabchevski, Sliven

    2011-06-01

    In this paper, we present and discuss experimental results from a microwave sintering of a silica-glass ceramic, produced from a silica xerogel extracted from a sago waste ash. As a radiation source for the microwave heating a sub-millimeter wave gyrotron (Gyrotron FU CW I) with an output frequency of 300 GHz has been used. The powders of silica xerogel have been dry pressed and then sintered at temperatures ranging from 300°C to 1500°C. The influence of the sintering temperature on the technological properties such as porosity and bulk density was studied in detail. Furthermore, X-ray diffraction (XRD) and Fourier Transform Infrared (FTIR) spectroscopy have been used in order to study the structure of the produced silica glass-ceramics. It has been found that the silica xerogel crystallizes at a temperature of 800°C, which is about 200°C lower than the one observed in the conventional process. The silica xerogel samples sintered by their irradiation with a sub-millimeter wave at 900°C for 18 minutes are fully crystallized into a silica glass-ceramic with a density of about 2.2 g/cm3 and cristobalite as a major crystalline phase. The results obtained in this study allow one to conclude that the microwave sintering with sub-millimeter waves is an appropriate technological process for production of silica glass-ceramics from a silica xerogel and is characterized with such advantages as shorter times of the thermal cycle, lower sintering temperatures and higher quality of the final product.

  12. Optoelectronic cross-injection locking of a dual-wavelength photonic integrated circuit for low-phase-noise millimeter-wave generation.

    Science.gov (United States)

    Kervella, Gaël; Van Dijk, Frederic; Pillet, Grégoire; Lamponi, Marco; Chtioui, Mourad; Morvan, Loïc; Alouini, Mehdi

    2015-08-01

    We report on the stabilization of a 90-GHz millimeter-wave signal generated from a fully integrated photonic circuit. The chip consists of two DFB single-mode lasers whose optical signals are combined on a fast photodiode to generate a largely tunable heterodyne beat note. We generate an optical comb from each laser with a microwave synthesizer, and by self-injecting the resulting signal, we mutually correlate the phase noise of each DFB and stabilize the beatnote on a multiple of the frequency delivered by the synthesizer. The performances achieved beat note linewidth below 30 Hz.

  13. Switching power converters medium and high power

    CERN Document Server

    Neacsu, Dorin O

    2013-01-01

    An examination of all of the multidisciplinary aspects of medium- and high-power converter systems, including basic power electronics, digital control and hardware, sensors, analog preprocessing of signals, protection devices and fault management, and pulse-width-modulation (PWM) algorithms, Switching Power Converters: Medium and High Power, Second Edition discusses the actual use of industrial technology and its related subassemblies and components, covering facets of implementation otherwise overlooked by theoretical textbooks. The updated Second Edition contains many new figures, as well as

  14. High-power electronics

    CERN Document Server

    Kapitsa, Petr Leonidovich

    1966-01-01

    High-Power Electronics, Volume 2 presents the electronic processes in devices of the magnetron type and electromagnetic oscillations in different systems. This book explores the problems of electronic energetics.Organized into 11 chapters, this volume begins with an overview of the motion of electrons in a flat model of the magnetron, taking into account the in-phase wave and the reverse wave. This text then examines the processes of transmission of electromagnetic waves of various polarization and the wave reflection from grids made of periodically distributed infinite metal conductors. Other

  15. Summary report of working group 3: Laser and high-gradient structure-based acceleration

    Science.gov (United States)

    Andonian, Gerard; Simakov, Evgenya

    2017-03-01

    High-gradient particle acceleration with reduced power demands is essential for miniaturization and cost reduction of future accelerators. Applications for compact accelerators span collider research for High Energy Physics, light source development for Basic Energy Sciences and National Security, and industrial accelerators for Energy and Environmental Applications. Working Group 3 discussed and surveyed the recent advances in achieving higher gradients and better acceleration efficiency in externally powered, structure-based accelerators. The topics covered in Working Group 3 included dielectric laser acceleration, millimeter-wave accelerators, breakdown phenomena, exotic topologies such as photonic band-gap structures, artificial materials, and nanostructures, and novel rf technology.

  16. High power coaxial ubitron

    Science.gov (United States)

    Balkcum, Adam J.

    In the ubitron, also known as the free electron laser, high power coherent radiation is generated from the interaction of an undulating electron beam with an electromagnetic signal and a static periodic magnetic wiggler field. These devices have experimentally produced high power spanning the microwave to x-ray regimes. Potential applications range from microwave radar to the study of solid state material properties. In this dissertation, the efficient production of high power microwaves (HPM) is investigated for a ubitron employing a coaxial circuit and wiggler. Designs for the particular applications of an advanced high gradient linear accelerator driver and a directed energy source are presented. The coaxial ubitron is inherently suited for the production of HPM. It utilizes an annular electron beam to drive the low loss, RF breakdown resistant TE01 mode of a large coaxial circuit. The device's large cross-sectional area greatly reduces RF wall heat loading and the current density loading at the cathode required to produce the moderate energy (500 keV) but high current (1-10 kA) annular electron beam. Focusing and wiggling of the beam is achieved using coaxial annular periodic permanent magnet (PPM) stacks without a solenoidal guide magnetic field. This wiggler configuration is compact, efficient and can propagate the multi-kiloampere electron beams required for many HPM applications. The coaxial PPM ubitron in a traveling wave amplifier, cavity oscillator and klystron configuration is investigated using linear theory and simulation codes. A condition for the dc electron beam stability in the coaxial wiggler is derived and verified using the 2-1/2 dimensional particle-in-cell code, MAGIC. New linear theories for the cavity start-oscillation current and gain in a klystron are derived. A self-consistent nonlinear theory for the ubitron-TWT and a new nonlinear theory for the ubitron oscillator are presented. These form the basis for simulation codes which, along

  17. Optical generation of radio-frequency power

    Energy Technology Data Exchange (ETDEWEB)

    Hietala, V.M.; Vawter, G.A.; Brennan, T.M.; Hammons, B.E.; Meyer, W.J.

    1994-11-01

    An optical technique for high-power radio-frequency (RF) signal generation is described. The technique uses a unique photodetector based on a traveling-wave design driven by an appropriately modulated light source. The traveling-wave photodetector (TWPD) exhibits simultaneously a theoretical quantum efficiency approaching 100 % and a very large electrical bandwidth. Additionally, it is capable of dissipating the high-power levels required for the RF generation technique. The modulated light source is formed by either the beating together of two lasers or by the direct modulation of a light source. A system example is given which predicts RF power levels of 100`s of mW`s at millimeter wave frequencies with a theoretical ``wall-plug`` efficiency approaching 34%.

  18. Millimeter-Wave Ultra-Wideband Bandpass Filter Employing Dual-Mode Ring Resonators Fed by Step-Impedance Coupled Lines

    Science.gov (United States)

    Cai, Peng; Ma, Zhewang; Kanzaki, Hitoshi; Zhang, Yong; Chen, Bin

    2009-05-01

    This paper presents a novel millimeter-wave ultra-wideband (UWB) bandpass filter (BPF) based on microstrip dual-mode rectangular ring resonators. In order to get strong coupling between the input/output line and the dual-mode ring resonators, a step-impedance parallel-coupled structure is adopted for the design of the filter. On the other hand, transmission zeros are produced by the dual-mode resonator. As a consequence, the filter has low insertion-loss in its passband, sharp attenuation in its lower and upper stopbands and very wide stopbands. As an example, a filter with two dual-mode ring resonators is designed and fabricated. The measured frequency property of the fabricated filter shows good agreement with the simulated response.

  19. Development of Millimeter-Wave Velocimetry and Acoustic Time-of-Flight Tomography for Measurements in Densely Loaded Gas-Solid Riser Flow

    Energy Technology Data Exchange (ETDEWEB)

    Fort, James A.; Pfund, David M.; Sheen, David M.; Pappas, Richard A.; Morgen, Gerald P.

    2007-04-01

    The MFDRC was formed in 1998 to advance the state-of-the-art in simulating multiphase turbulent flows by developing advanced computational models for gas-solid flows that are experimentally validated over a wide range of industrially relevant conditions. The goal was to transfer the resulting validated models to interested US commercial CFD software vendors, who would then propagate the models as part of new code versions to their customers in the US chemical industry. Since the lack of detailed data sets at industrially relevant conditions is the major roadblock to developing and validating multiphase turbulence models, a significant component of the work involved flow measurements on an industrial-scale riser contributed by Westinghouse, which was subsequently installed at SNL. Model comparisons were performed against these datasets by LANL. A parallel Office of Industrial Technology (OIT) project within the consortium made similar comparisons between riser measurements and models at NETL. Measured flow quantities of interest included volume fraction, velocity, and velocity-fluctuation profiles for both gas and solid phases at various locations in the riser. Some additional techniques were required for these measurements beyond what was currently available. PNNL’s role on the project was to work with the SNL experimental team to develop and test two new measurement techniques, acoustic tomography and millimeter-wave velocimetry. Acoustic tomography is a promising technique for gas-solid flow measurements in risers and PNNL has substantial related experience in this area. PNNL is also active in developing millimeter wave imaging techniques, and this technology presents an additional approach to make desired measurements. PNNL supported the advanced diagnostics development part of this project by evaluating these techniques and then by adapting and developing the selected technology to bulk gas-solids flows and by implementing them for testing in the SNL riser

  20. High average power supercontinuum sources

    Indian Academy of Sciences (India)

    .uk. Abstract. The physical mechanisms and basic experimental techniques for the creation of high average spectral power supercontinuum sources is briefly reviewed. We focus on the use of high-power ytterbium-doped fibre lasers as pump ...

  1. Imaging of spatial distributions of the millimeter wave intensity by using visible continuum radiation from a discharge in a Cs-Xe mixture. Part I: Review of the method and its fundamentals

    Science.gov (United States)

    Gitlin, M. S.

    2017-02-01

    The first part of the review is presented which is dedicated to the time-resolved method of imaging and measuring the spatial distribution of the intensity of millimeter waves by using visible continuum (VC) emitted by the positive column (PC) of a dc discharge in a mixture of cesium vapor with xenon. The review focuses on the operating principles, fundamentals, and applications of this new technique. The design of the discharge tube and experimental setup used to create a wide homogeneous plasma slab with the help of the Cs-Xe discharge at a gas pressure of 45 Torr are described. The millimeter-wave effects on the plasma slab are studied experimentally. The mechanism of microwave-induced variations in the VC brightness and the causes of violation of the local relation between the VC brightness and the intensity of millimeter waves are discussed. Experiments on the imaging of the field patterns of horn antennas and quasi-optical beams demonstrate that this technique can be used for good-quality imaging of millimeter-wave beams in the entire millimeter-wavelength band. The method has a microsecond temporal resolution and a spatial resolution of about 2 mm. Energy sensitivities of about 10 μJ/cm2 in the Ka-band and about 200 μJ/cm2 in the D-band have been demonstrated.

  2. Imaging of spatial distributions of the millimeter wave intensity by using visible continuum radiation from a discharge in a Cs–Xe mixture. Part I: Review of the method and its fundamentals

    Energy Technology Data Exchange (ETDEWEB)

    Gitlin, M. S., E-mail: gitlin@appl.sci-nnov.ru [Russian Academy of Sciences, Institute of Applied Physics (Russian Federation)

    2017-02-15

    The first part of the review is presented which is dedicated to the time-resolved method of imaging and measuring the spatial distribution of the intensity of millimeter waves by using visible continuum (VC) emitted by the positive column (PC) of a dc discharge in a mixture of cesium vapor with xenon. The review focuses on the operating principles, fundamentals, and applications of this new technique. The design of the discharge tube and experimental setup used to create a wide homogeneous plasma slab with the help of the Cs–Xe discharge at a gas pressure of 45 Torr are described. The millimeter-wave effects on the plasma slab are studied experimentally. The mechanism of microwave-induced variations in the VC brightness and the causes of violation of the local relation between the VC brightness and the intensity of millimeter waves are discussed. Experiments on the imaging of the field patterns of horn antennas and quasi-optical beams demonstrate that this technique can be used for good-quality imaging of millimeter-wave beams in the entire millimeter-wavelength band. The method has a microsecond temporal resolution and a spatial resolution of about 2 mm. Energy sensitivities of about 10 μJ/cm{sup 2} in the Ka-band and about 200 μJ/cm{sup 2} in the D-band have been demonstrated.

  3. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    and maximum output power. In chapter 3, a detailed analysis of dominant loss factors in high power converters for low voltage applications is presented. The analysis concludes that: • Power transformers for low voltage high power, if properly designed, will have extremely low leakage inductance......The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based....... • If optimally designed, boost converters will be much more efficient than comparable buck type converters for high power low voltage applications. • The use of voltage clamp circuits to protect primary switches in boost converters is no longer needed for device protection. On the other hand...

  4. Systematic Observation of Time-Dependent Phenomena in the RF Output Spectrum of High Power Gyrotrons

    Directory of Open Access Journals (Sweden)

    Kern Stefan

    2012-09-01

    Full Text Available At IHM/KIT, high power gyrotrons with conventional cavity (e.g. 1 MW CW at 140 GHz for the stellarator Wendelstein 7-X and coaxial cavity (2 MW shortpulse at 170 GHz for ITER for fusion applications are being developed and verified experimentally. Especially with respect to the problem of parasitic RF oscillations in the beam tunnel of some W7-X tubes, investigations of the gyrotron RF output spectrum have proved to be a valuable source of diagnostic information. Signs of transient effects in millisecond pulses, like frequency switching or intermittent low-frequency modulation, have indicated that truly time-dependent measurements with high frequency resolution and dynamic range could give deeper insight into these phenomena. In this paper, an improved measurement system is presented, which employs a fast oscilloscope as receiver. Shorttime Fourier transform (STFT is applied to the time-domain signal, yielding time-variant spectra with frequency resolutions only limited by acquisition length and STFT segmentation choice. Typical reasonable resolutions are in the range of 100 kHz to 10 MHz with a currently memory-limited maximum acquisition length of 4 ms. A key feature of the system consists in the unambiguity of frequency measurement: The system receives through two parallel channels, each using a harmonic mixer (h = 9 – 12 to convert the signal from RF millimeter wave frequencies (full D-Band, 110 – 170 GHz to IF (0 – 3 GHz. For each IF output signal of each individual mixer, injection side and receiving harmonic are initially not known. Using accordingly determined LO frequencies, this information is retrieved from the redundancy of the channels, yielding unambiguously reconstructed RF spectra with a total span of twice the usable receiver IF bandwidth, up to ≈ 6 GHz in our case. Using the system, which is still being improved continuously, various transient effects like cavity mode switching, parasitic oscillation frequency variation

  5. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    . A detailed analysis of dominant loss factors in high power converters for low voltage applications is presented. The analysis concludes that: • Power transformers for low voltage high power, if properly designed, will have extremely low leakage inductance. • If optimally designed, boost converters......The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based......, if a converter is properly designed, primary side voltage clamp circuits will not even work in low voltage high power converters. • Very high conversion efficiency can be achieved. Peak efficiency of 98% and worst case minimum efficiency of 96.8% are demonstrated on a 1.5 kW converter. The ability...

  6. Integral staggered point-matching method for millimeter-wave reflective diffraction gratings on electron cyclotron heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Donghui [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, 430074 Wuhan (China); Huang, Mei [Southwestern Institute of Physics, 610041 Chengdu (China); Wang, Zhijiang, E-mail: wangzj@hust.edu.cn [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, 430074 Wuhan (China); Zhang, Feng [Southwestern Institute of Physics, 610041 Chengdu (China); Zhuang, Ge [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, 430074 Wuhan (China)

    2016-10-15

    Highlights: • The integral staggered point-matching method for design of polarizers on the ECH systems is presented. • The availability of the integral staggered point-matching method is checked by numerical calculations. • Two polarizers are designed with the integral staggered point-matching method and the experimental results are given. - Abstract: The reflective diffraction gratings are widely used in the high power electron cyclotron heating systems for polarization strategy. This paper presents a method which we call “the integral staggered point-matching method” for design of reflective diffraction gratings. This method is based on the integral point-matching method. However, it effectively removes the convergence problems and tedious calculations of the integral point-matching method, making it easier to be used for a beginner. A code is developed based on this method. The calculation results of the integral staggered point-matching method are compared with the integral point-matching method, the coordinate transformation method and the low power measurement results. It indicates that the integral staggered point-matching method can be used as an optional method for the design of reflective diffraction gratings in electron cyclotron heating systems.

  7. High-Efficiency Power Module

    Science.gov (United States)

    Simons, Rainee N. (Inventor); Wintucky, Edwin G. (Inventor)

    2015-01-01

    One or more embodiments of the present invention pertain to an all solid-state microwave power module. The module includes a plurality of solid-state amplifiers configured to amplify a signal using a low power stage, a medium power stage, and a high power stage. The module also includes a power conditioner configured to activate a voltage sequencer (e.g., bias controller) when power is received from a power source. The voltage sequencer is configured to sequentially apply voltage to a gate of each amplifier and sequentially apply voltage to a drain of each amplifier.

  8. High Power Orbit Transfer Vehicle

    National Research Council Canada - National Science Library

    Gulczinski, Frank

    2003-01-01

    ... from Virginia Tech University and Aerophysics, Inc. to examine propulsion requirements for a high-power orbit transfer vehicle using thin-film voltaic solar array technologies under development by the Space Vehicles Directorate (dubbed PowerSail...

  9. High power evaluation of X-band high power loads

    CERN Document Server

    Matsumoto, Shuji; Syratchev, Igor; Riddone, Germana; Wuensch, Walter

    2010-01-01

    Several types of X-band high power loads developed for several tens of MW range were designed, fabricated and used for high power tests at X-band facility of KEK. Some of them have been used for many years and few units showed possible deterioration of RF performance. Recently revised-design loads were made by CERN and the high power evaluation was performed at KEK. In this paper, the main requirements are recalled, together with the design features. The high power test results are analysed and presented

  10. high power facto high power factor high power factor hybrid rectifier

    African Journals Online (AJOL)

    eobe

    compact and efficient new devices, it noted increase in the number of electrical loads that some kind of electronic ... in electric machines and capacitors,. HIGH POWER FACTOR. HIGH POWER FACTOR HYBRID ...... Auxiliary DC-DC Converter for Hybrid Vehicles ”,. IEEE Transactions on Power Electronics vol. 23, no. 6, pp.

  11. High average power supercontinuum sources

    Indian Academy of Sciences (India)

    The physical mechanisms and basic experimental techniques for the creation of high average spectral power supercontinuum sources is briefly reviewed. We focus on the use of high-power ytterbium-doped fibre lasers as pump sources, and the use of highly nonlinear photonic crystal fibres as the nonlinear medium.

  12. Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz

    Science.gov (United States)

    Fung, King Man; Ward, John; Chattopadhyay, Goutam; Lin, Robert H.; Samoska, Lorene A.; Kangaslahti, Pekka P.; Mehdi, Imran; Lambrigtsen, Bjorn H.; Goldsmith, Paul F.; Soria, Mary M.; hide

    2011-01-01

    Future remote sensing instruments will require focal plane spectrometer arrays with higher resolution at high frequencies. One of the major components of spectrometers are the local oscillator (LO) signal sources that are used to drive mixers to down-convert received radio-frequency (RF) signals to intermediate frequencies (IFs) for analysis. By advancing LO technology through increasing output power and efficiency, and reducing component size, these advances will improve performance and simplify architecture of spectrometer array systems. W-band power amplifiers (PAs) are an essential element of current frequency-multiplied submillimeter-wave LO signal sources. This work utilizes GaN monolithic millimeter-wave integrated circuit (MMIC) PAs developed from a new HRL Laboratories LLC 0.15- m gate length GaN semiconductor transistor. By additionally waveguide power combining PA MMIC modules, the researchers here target the highest output power performance and efficiency in the smallest volume achievable for W-band.

  13. Millimeter-wave sensor based on a λ/2-line resonator for identification and dielectric characterization of non-ionic surfactants.

    Science.gov (United States)

    Rodilla, H; Kim, A A; Jeffries, G D M; Vukusic, J; Jesorka, A; Stake, J

    2016-01-20

    Studies of biological and artificial membrane systems, such as niosomes, currently rely on the use of fluorescent tags, which can influence the system under investigation. For this reason, the development of label-free, non-invasive detection techniques is of great interest. We demonstrate an open-volume label-free millimeter-wave sensing platform based on a coplanar waveguide, developed for identification and characterization of niosome constituents. A design based on a λ/2-line resonator was used and on-wafer measurements of transmission and reflection parameters were performed up to 110 GHz. Our sensor was able to clearly distinguish between common niosome constituents, non-ionic surfactants Tween 20 and Span 80, measuring a resonance shift of 3 GHz between them. The complex permittivities of the molecular compounds have been extracted. Our results indicate insignificant frequency dependence in the investigated frequency range (3 GHz - 110 GHz). Values of permittivity around 3.0 + 0.7i and 2.2 + 0.4i were obtained for Tween 20 and Span 80, respectively.

  14. Preparation, Characterization, and Millimeter Wave Attenuation of Carbon Fibers Coated with Ni-Cu-P and Ni-Co-P Alloys

    Science.gov (United States)

    Ye, Mingquan; Li, Zhitao; Wang, Chen; Han, Aijun

    2015-12-01

    Composite carbon fibers (CFs) coated with Ni-X-P (X = Cu, Co, none) alloys were prepared by electroless plating. The morphology, crystal structure, elemental composition, and millimeter wave (MMW) attenuation performance of the alloy-coated CFs were characterized by scanning electron microscopy, x-ray diffractometry, energy-dispersive spectrometry, and microwave attenuation. CFs were coated with a layer of alloy particles. The P content in the Ni-Cu-P or Ni-Co-P-coated alloy was lower than that in the Ni-P alloy, and coating alloy Ni-P was amorphous. Coating alloys exhibited crystal characteristics after Cu or Co introduction. MMW-attenuation performance of alloy-coated CFs showed that the 3 and 8 mm wave-attenuation effects of CF/Ni-Cu-P and CF/Ni-Co-P were better than those of CF/Ni-P and CFs. The 8 mm wave-attenuation values and their increases were larger than those of the 3 mm wave. The MMW-attenuation performance is attributable to the alloy bulk resistivity and P content. The 3 mm wave-attenuation effects of wavelength-coated CF samples were slightly larger than those of the half wavelength samples. An optimal weight gain value existed for the MMW-attenuation performance of alloy-coated CFs.

  15. Step Width Tolerable for Offset of the Aperture in a Millimeter-Wave Transducer between Post-Wall and Hollow Standard Waveguides

    Science.gov (United States)

    Lee, Jungaun; Hirokawa, Jiro; Ando, Makoto

    A transducer with a wide step from a post-wall waveguide to a hollow waveguide width is proposed which is tolerant against the aperture offset. The modes in the step width of about 1.50 wavelengths are stable for the aperture offset and the fields are not so perturbed while in the conventional stepped structure with step width of about 1.00 wavelength, the higher evanescent mode of TE30 is excessively enhanced by the aperture offset. The operation of the transducer with the wider step is robust for the fabrication errors in the millimeter wave band. It is also suggested that the anti-symmetrical TE20 mode which is excited only by non-zero offset or the misalignment of the aperture exists in both structures and can not be the dominant factor for the improvement. The transducers are designed and fabricated at 61.25GHz using PTFE substrate with glass fiber of εr=2.17. The bandwidth for the reflection lower than -15dB is almost unchanged (6.30-6.60GHz) for the offset from -0.2mm to 0.2mm, while it is degraded in the conventional stepped structure, from 7.65GHz for no offset to 3.30-5.70GHz for the same range of the offset.

  16. High-powered manoeuvres

    CERN Multimedia

    Anaïs Schaeffer

    2013-01-01

    This week, CERN received the latest new transformers for the SPS. Stored in pairs in 24-tonne steel containers, these transformers will replace the old models, which have been in place since 1981.     The transformers arrive at SPS's access point 4 (BA 4). During LS1, the TE-EPC Group will be replacing all of the transformers for the main converters of the SPS. This renewal campaign is being carried out as part of the accelerator consolidation programme, which began at the start of April and will come to an end in November. It involves 80 transformers: 64 with a power of 2.6 megavolt-amperes (MVA) for the dipole magnets, and 16 with 1.9 MVA for the quadrupoles. These new transformers were manufactured by an Italian company and are being installed outside the six access points of the SPS by the EN-HE Group, using CERN's 220-tonne crane. They will contribute to the upgrade of the SPS, which should thus continue to operate as the injector for the LHC until 2040....

  17. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    Science.gov (United States)

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  18. High-power downhole motor

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, J.H.; Maurer, W.C.; Evans, C.R. [Maurer Engineering Inc., Houston, TX (United States); Westcott, P.A. [Gas Research Inst., Chicago, IL (United States)

    1995-12-31

    New high power motors are being developed by the Gas Research Institute (GRI) in an attempt to reduce drilling costs in deep gas wells. Conventional 2 3/8-in. (60-mm) and 3 3/8-in. (86-mm) motors operated in overpowered conditions (i.e., high flow rates and high differential pressures) drill 2 to 3 times faster than conventional motors. A new high-power 3 3/8-in. (86-mm) motor is being developed that utilizes additional stages and tighter interference between the rotor and stator to increase motor pressure drop, torque, and power output. This new high-power motor delivers up to 238 hp (177 kW) compared to 50 hp (37 kW) for a conventional 3 3/8-in. (86-mm) motor operating at rated operating conditions. Temperature probes showed that temperatures in different stages of motors vary considerably, showing that some sections do more work than others. A better understanding of temperatures within the stators is needed because thermal degradation and ``chunking`` of the rubber is a leading cause of failures in motors operating at high power levels. These tests were very encouraging, demonstrating the feasibility of developing reliable, high-power motors.

  19. EURISOL High Power Targets

    CERN Document Server

    Kadi, Y; Lindroos, M; Ridikas, D; Stora, T; Tecchio, L; CERN. Geneva. BE Department

    2009-01-01

    Modern Nuclear Physics requires access to higher yields of rare isotopes, that relies on further development of the In-flight and Isotope Separation On-Line (ISOL) production methods. The limits of the In-Flight method will be applied via the next generation facilities FAIR in Germany, RIKEN in Japan and RIBF in the USA. The ISOL method will be explored at facilities including ISAC-TRIUMF in Canada, SPIRAL-2 in France, SPES in Italy, ISOLDE at CERN and eventually at the very ambitious multi-MW EURISOL facility. ISOL and in-flight facilities are complementary entities. While in-flight facilities excel in the production of very short lived radioisotopes independently of their chemical nature, ISOL facilities provide high Radioisotope Beam (RIB) intensities and excellent beam quality for 70 elements. Both production schemes are opening vast and rich fields of nuclear physics research. In this article we will introduce the targets planned for the EURISOL facility and highlight some of the technical and safety cha...

  20. High Power Betavoltaic Technology Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation will dramatically improve the performance of tritium-powered betavoltaic batteries through the development of a high-aspect ratio, expanded...

  1. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  2. High Power Amplifier and Power Supply

    Science.gov (United States)

    Duong, Johnny; Stride, Scot; Harvey, Wayne; Haque, Inam; Packard, Newton; Ng, Quintin; Ispirian, Julie Y.; Waian, Christopher; Janes, Drew

    2008-01-01

    A document discusses the creation of a high-voltage power supply (HVPS) that is able to contain voltages up to -20 kV, keep electrical field strengths to below 200 V/mil (approximately equal to 7.87 kV/mm), and can provide a 200-nanosecond rise/fall time focus modulator swinging between cathode potential of 16.3 kV and -19.3 kV. This HVPS can protect the 95-GHz, pulsed extended interaction klystron (EIK) from arcs/discharges from all sources, including those from within the EIK fs vacuum envelope. This innovation has a multi-winding pulse transformer design, which uses new winding techniques to provide the same delays and rise/fall times (less than 10 nanoseconds) at different potential levels ranging from -20 kV to -16 kV. Another feature involves a high-voltage printed-wiring board that was corona-free at -20 kV DC with a 3- kV AC swing. The corona-free multilayer high-voltage board is used to simulate fields of less than 200 V/mil (approximately equal to 7.87 kV/mm) at 20 kV DC. Drive techniques for the modulator FETs (field-effect transistors) (four to 10 in a series) were created to change states (3,000-V swing) without abrupt steps, while still maintaining required delays and transition times. The packing scheme includes a potting mold to house a ten-stage modulator in the space that, in the past, only housed a four-stage modulator. Problems keeping heat down were solved using aluminum oxide substrate in the high-voltage section to limit temperature rise to less than 10 while withstanding -20 kV DC voltage and remaining corona-free.

  3. Classification and modeling of human activities using empirical mode decomposition with S-band and millimeter-wave micro-Doppler radars

    Science.gov (United States)

    Fairchild, Dustin P.; Narayanan, Ram M.

    2012-06-01

    The ability to identify human movements can be an important tool in many different applications such as surveillance, military combat situations, search and rescue operations, and patient monitoring in hospitals. This information can provide soldiers, security personnel, and search and rescue workers with critical knowledge that can be used to potentially save lives and/or avoid a dangerous situation. Most research involving human activity recognition is focused on using the Short-Time Fourier Transform (STFT) as a method of analyzing the micro-Doppler signatures. Because of the time-frequency resolution limitations of the STFT and because Fourier transform-based methods are not well-suited for use with non-stationary and nonlinear signals, we have chosen a different approach. Empirical Mode Decomposition (EMD) has been shown to be a valuable time-frequency method for processing non-stationary and nonlinear data such as micro-Doppler signatures and EMD readily provides a feature vector that can be utilized for classification. For classification, the method of a Support Vector Machine (SVMs) was chosen. SVMs have been widely used as a method of pattern recognition due to their ability to generalize well and also because of their moderately simple implementation. In this paper, we discuss the ability of these methods to accurately identify human movements based on their micro-Doppler signatures obtained from S-band and millimeter-wave radar systems. Comparisons will also be made based on experimental results from each of these radar systems. Furthermore, we will present simulations of micro-Doppler movements for stationary subjects that will enable us to compare our experimental Doppler data to what we would expect from an "ideal" movement.

  4. Analysis of frequency quadrupling using a single Mach-Zehnder modulator for millimeter-wave generation and distribution over fiber systems.

    Science.gov (United States)

    Mohamed, Mohmoud; Zhang, Xiupu; Hraimel, Bouchaib; Wu, Ke

    2008-07-07

    We comprehensively investigate three modulation techniques for the generation of millimeter-wave (mm-wave) using optical frequency quadrupling with a dual???electrode Mach-Zehnder modulator (MZM), i.e. Technique-A, Technique-B and Technique-C. For Technique-A, an RF signal drives the two electrodes of the MZM with maximum transmission bias, and this MZM is used for both the mm-wave generation and signal modulation. Technique-B is the same as Technique-A, but 180(0) phase shift between the two electrodes is applied. Technique-C is the same as Technique-B, but the MZM is only used for the mm-wave generation without signal modulation. It is found that Technique-B and Technique-C are better for frequency quadrupling than frequency doubling, tripling and sextupling. Both theoretical analysis and simulation show that the generated mm-wave suffers from constructive/destructive interaction due to fiber chromatic dispersion in Technique-A. However, the generated mm-wave is almost robust to fiber chromatic dispersion in Technique-B and Technique- C. It is found that Technique-C is the best in the quality of the generated mm-wave, especially when poor optical filtering is used. In addition, we develop a theory for calculation of Q-factor for mm-wave generation using the three modulation techniques. We consider an RF at 7.5 GHz and obtain an mm-wave at 30 GHz as an example, i.e. a frequency quadrupler. We evaluate the generation and distribution in terms of system Q-factor. The impact of RF modulation index, chromatic dispersion, MZM extinction ratio and optical filtering on Q-factor are investigated.

  5. SIW based multilayer transition and power divider in LTCC technology

    KAUST Repository

    Abuzaid, Hattan

    2013-06-01

    A multilayer transition and balanced power divider are presented for millimeter-wave system-on-package (SoP). These two components operate at Ka-band and exploit the substrate integrate waveguide (SIW) technology with its shielding characteristics and the Low-temperature co-fired ceramics (LTCC) technology for its high density integration. A coupling slot has been used to perform vertical integration, which can be easily optimized through its length. The measured input return loss within the bandwidth of interest (32 GHz-38 GHz) is less than -15 dB and -18 dB for the multilayer transition and the power divider, respectively. The lateral dimensions of a multilayer system, such as a feed network of an array, can be greatly reduced by employing these 3D slot-coupled components. © 2013 IEEE.

  6. Development of Measurement and Extraction Technique of Complex Permittivity Using Transmission Parameter S 21 for Millimeter Wave Frequencies

    Science.gov (United States)

    Ozturk, Turgut; Hudlička, Martin; Uluer, İhsan

    2017-12-01

    This study provides an overview of measured S-parameters and its processing to extract the dielectric properties of materials such as Teflon, PMMA, and PVC which are preferred for materials characterization process. In addition, a correction model is presented for transmission parameter ( S 21) to obtain the dielectric constant with high accuracy. A non-destructive and non-contact free space measurement method has been used to measure S-parameters of thin samples in the low THz frequency range. S-parameters are measured in free space by vector network analyzer supported with two frequency extenders. Additionally, the parabolic mirrors are used to collimate the generated beam in wide frequency range. Furthermore, a standard filter process is performed to remove the undesired ripples in signal using singular spectrum analyzer before the implementation of extraction process. Newton-Raphson extraction technique is used to extract the material complex permittivity as a function of the frequency in Y-band (325-500 GHz).

  7. High power neutron production targets

    Energy Technology Data Exchange (ETDEWEB)

    Wender, S. [Los Alamos National Lab., NM (United States)

    1996-06-01

    The author describes issues of concern in the design of targets and associated systems for high power neutron production facilities. The facilities include uses for neutron scattering, accelerator driven transmutation, accelerator production of tritium, short pulse spallation sources, and long pulse spallation sources. Each of these applications requires a source with different design needs and consequently different implementation in practise.

  8. High Power Electron Accelerator Prototype

    CERN Document Server

    Tkachenko, Vadim; Cheskidov, Vladimir; Korobeynikov, G I; Kuznetsov, Gennady I; Lukin, A N; Makarov, Ivan; Ostreiko, Gennady; Panfilov, Alexander; Sidorov, Alexey; Tarnetsky, Vladimir V; Tiunov, Michael A

    2005-01-01

    In recent time the new powerful industrial electron accelerators appear on market. It caused the increased interest to radiation technologies using high energy X-rays due to their high penetration ability. However, because of low efficiency of X-ray conversion for electrons with energy below 5 MeV, the intensity of X-rays required for some industrial applications can be achieved only when the beam power exceeds 300 kW. The report describes a project of industrial electron accelerator ILU-12 for electron energy up to 5 MeV and beam power up to 300 kW specially designed for use in industrial applications. On the first stage of work we plan to use the existing generator designed for ILU-8 accelerator. It is realized on the GI-50A triode and provides the pulse power up to 1.5-2 MW and up to 20-30 kW of average power. In the report the basic concepts and a condition of the project for today are reflected.

  9. Millimeter Wave Radar Clutter Program

    Science.gov (United States)

    1989-10-30

    millirneier-weve "~wort analyzer hajift scscarernmr. *Rep. an ’outasaanding ftiactncal eniginiveringl profesor is the Ls-ied Stati of 022872- 1 T...statis- that were mounted on the same platform and their beams tics is given in Table 11. pointed along the same direction as that of the scatterom...clutter charactetis- tics . -in AGi4RD Calif Pro, No 66 Advanced Raadar Svutents. Nlov 1970 1151 R ft Smotes.The Weibull distribution applied to the

  10. Electrooptics and Millimeter Wave Lab

    Data.gov (United States)

    Federal Laboratory Consortium — Design, develop and evaluate optical processors; combine lenses, mirrors and laser diodes to process data at light speed. Research to date has resulted in the flight...

  11. Millimeter Wave Electromagnetic Measurement Techniques.

    Science.gov (United States)

    1982-05-01

    in the Nonlinear Portion of the p• 4 Mixer’scu Chaaceritis) 2 C- 2 o4h p 0,1,2,3,..., and q = 1,2,3.... In Equation C-1 p represents the harmonic of...07703 US Army Topographic Labs ATTN: ETL- TD -EA 519 CDR, US Army Avionics Lab 001 Fort Belvoir, VA 22060 AVRADCOM ATTN: DAVAA-D 572 Commander 001 Fort...Powder Mill Road ATTN: Mr. Leedy 001 Adelphi, MD 20783 001 Washington, DC 20231 622 HQ, Harry Diamond Lab 707 TACTECATTN: DELHD- TD (Dr. W.W. Carter

  12. Millimeter wave spectroscopic measurements over the South Pole: 3. The behavior of stratospheric nitric acid through polar fall, winter, and spring

    Science.gov (United States)

    de Zafra, R. L.; Chan, V.; Crewell, S.; Trimble, C.; Reeves, J. M.

    1997-01-01

    We present data from a 9-month series of ground-based measurements of stratospheric nitric acid, made over the South Pole from mid-April 1993 to mid-January 1994. Observations were typically made at 3- to 6-day intervals. Both profiles and column densities have been retrieved from pressure-broadened millimeter-wave emission spectra. These measurements provide the first quasi-continuous series of vertical mixing ratio profiles for this species in the heart of the south polar votex. Conversion of NOx to nitric acid by heterogeneous reactions, and its incorporation into polar stratospheric cloud (PSC) particles, along with subsequent gravitational settling, is considered to be the main denitrifying mechanism in the Antarctic stratosphere, setting up conditions for ozone destruction at the end of winter. In our observations, a small increase in HNO3 was seen between April and the end of May, after which a rapid loss took place below 25 km. Column density above ˜15 km decreased to ≤1/4 its maximum within 30 days, and depletion continued until middle to late July, by which time the nitric acid column above 15 km had diminished by more than a factor of 10. The initial depletion was coincident with the onset of a rapid increase in lidar backscatter from polar stratospheric cloud formation at the same altitude range. Gas-phase depletion was tracked as a function of altitude and temperature and found to be consistent with the temperature and partial pressure relationship for formation of ternary mixtures of HNO3, H2SO4, and H2O. Depletion occurred ˜3 weeks earlier in 1993 than was seen in 1992 column density measurements by Van Allen et al. [1995]. In late June a new layer of HNO3 was generated in the vicinity of 40-km altitude and, subsequently, appeared to be carried downward with general vertical transport of air within the vortex. In spring, as temperatures increased, no rapid increase of gas-phase HNO3 was seen, indicating that gravitational settling had carried PSC

  13. Remote heterodyne millimeter-wave over fiber based OFDM-PON with master-to-slave injected dual-mode colorless FPLD pair.

    Science.gov (United States)

    Chen, Hsiang-Yu; Chi, Yu-Chieh; Lin, Gong-Ru

    2015-08-24

    A remote heterodyne millimeter-wave (MMW) carrier at 47.7 GHz over fiber synthesized with the master-to-slave injected dual-mode colorless FPLD pair is proposed, which enables the future connection between the wired fiber-optic 64-QAM OFDM-PON at 24 Gb/s with the MMW 4-QAM OFDM wireless network at 2 Gb/s. Both the single- and dual-mode master-to-slave injection-locked colorless FPLD pairs are compared to optimize the proposed 64-QAM OFDM-PON. For the unamplified single-mode master, the slave colorless FPLD successfully performs the 64-QAM OFDM data at 24 Gb/s with EVM, SNR and BER of 8.5%, 21.5 dB and 2.9 × 10(-3), respectively. In contrast, the dual-mode master-to-slave injection-locked colorless FPLD pair with amplified and unfiltered master can transmit 64-QAM OFDM data at 18 Gb/s over 25-km SMF to provide EVM, SNR and BER of 8.2%, 21.8 dB and 2.2 × 10(-3), respectively. For the dual-mode master-to-slave injection-locked colorless FPLD pair, even though the modal dispersion occurred during 25-km SMF transmission makes it sacrifice the usable OFDM bandwidth by only 1 GHz, which guarantees the sufficient encoding bitrate for the optically generated MMW carrier to implement the fusion of MMW wireless LAN and DWDM-PON with cost-effective and compact architecture. As a result, the 47.7-GHz MMW carrier remotely beat from the dual-mode master-to-slave injection-locked colorless FPLD pair exhibits an extremely narrow bandwidth of only 0.48 MHz. After frequency down-conversion operation, the 47.7-GHz MMW carrier successfully delivers 4-QAM OFDM data up to 2 Gb/s with EVM, SNR and BER of 33.5%, 9.51 dB and 1.4 × 10(-3), respectively.

  14. High temperature, high power piezoelectric composite transducers.

    Science.gov (United States)

    Lee, Hyeong Jae; Zhang, Shujun; Bar-Cohen, Yoseph; Sherrit, Stewart

    2014-08-08

    Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined.

  15. High-power radio frequency pulse generation and extration based on wakefield excited by an intense charged particle beam in dielectric-loaded waveguides.

    Energy Technology Data Exchange (ETDEWEB)

    Gao, F.; High Energy Physics; Illinois Inst. of Tech

    2009-07-24

    Power extraction using a dielectric-loaded (DL) waveguide is a way to generate high-power radio frequency (RF) waves for future particle accelerators, especially for two-beam-acceleration. In a two-beam-acceleration scheme, a low-energy, high-current particle beam is passed through a deceleration section of waveguide (decelerator), where the power from the beam is partially transferred to trailing electromagnetic waves (wakefields); then with a properly designed RF output coupler, the power generated in the decelerator is extracted to an output waveguide, where finally the power can be transmitted and used to accelerate another usually high-energy low-current beam. The decelerator, together with the RF output coupler, is called a power extractor. At Argonne Wakefield Accelerator (AWA), we designed a 7.8GHz power extractor with a circular DL waveguide and tested it with single electron bunches and bunch trains. The output RF frequency (7.8GHz) is the sixth harmonic of the operational frequency (1.3GHz) of the electron gun and the linac at AWA. In single bunch excitation, a 1.7ns RF pulse with 30MW of power was generated by a single 66nC electron bunch passing through the decelerator. In subsequent experiments, by employing different splitting-recombining optics for the photoinjector laser, electron bunch trains were generated and thus longer RF pulses could be successfully generated and extracted. In 16-bunch experiments, 10ns and 22ns RF pulses have been generated and extracted; and in 4-bunch experiments, the maximum power generated was 44MW with 40MW extracted. A 26GHz DL power extractor has also been designed to test this technique in the millimeter-wave range. A power level of 148MW is expected to be generated by a bunch train with a bunch spacing of 769ps and bunch charges of 20nC each. The arrangement for the experiment is illustrated in a diagram. Higher-order-mode (HOM) power extraction has also been explored in a dual-frequency design. By using a bunch

  16. High power gas laser amplifier

    Science.gov (United States)

    Leland, Wallace T.; Stratton, Thomas F.

    1981-01-01

    A high power output CO.sub.2 gas laser amplifier having a number of sections, each comprising a plurality of annular pumping chambers spaced around the circumference of a vacuum chamber containing a cold cathode, gridded electron gun. The electron beam from the electron gun ionizes the gas lasing medium in the sections. An input laser beam is split into a plurality of annular beams, each passing through the sections comprising one pumping chamber.

  17. A 23 GHz low power VCO in SiGe BiCMOS technology

    Science.gov (United States)

    Yinkun, Huang; Danyu, Wu; Lei, Zhou; Fan, Jiang; Jin, Wu; Zhi, Jin

    2013-04-01

    A 23 GHz voltage controlled oscillator (VCO) with very low power consumption is presented. This paper presents the design and measurement of an integrated millimeter wave VCO. This VCO employs an on-chip inductor and MOS varactor to form a high Q resonator. The VCO RFIC was implemented in a 0.18 μm 120 GHz ft SiGe hetero-junction bipolar transistor (HBT) BiCMOS technology. The VCO oscillation frequency is around 23 GHz, targeting at the ultra wideband (UWB) and short range radar applications. The core of the VCO circuit consumes 1 mA current from a 2.5 V power supply and the VCO phase noise was measured at around -94 dBc/Hz at a 1 MHz frequency offset. The FOM of the VCO is -177 dBc/Hz.

  18. Design and analysis of 30 nm T-gate InAlN/GaN HEMT with AlGaN back-barrier for high power microwave applications

    Science.gov (United States)

    Murugapandiyan, P.; Ravimaran, S.; William, J.; Meenakshi Sundaram, K.

    2017-11-01

    In this article, we present the DC and microwave characteristics of a novel 30 nm T-gate InAlN/AlN/GaN HEMT with AlGaN back-barrier. The device structure is simulated by using Synopsys Sentaurus TCAD Drift-Diffusion transport model at room temperature. The device features are heavily doped (n++ GaN) source/drain regions with Si3N4 passivated device surface for reducing the contact resistances and gate capacitances of the device, which uplift the microwave characteristics of the HEMTs. 30 nm gate length D-mode (E-mode) HEMT exhibited a peak drain current density Idmax of 2.3 (2.42) A/mm, transconductance gm of 1.24(1.65) S/mm, current gain cut-off frequency ft of 262 (246) GHz, power gain cut-off frequency fmax of 246(290) GHz and the three terminal off-state breakdown voltage VBR of 40(38) V. The preeminent microwave characteristics with the higher breakdown voltage of the proposed GaN-based HEMT are the expected to be the most optimistic applicant for future high power millimeter wave applications.

  19. Microwave and Millimeter-Wave Remote Sensing for Security Applications. By Jeffrey A. Nanzer, Artech House, 2012; 372 pages. Price £109.00, ISBN 978-1-60807-172-2

    Directory of Open Access Journals (Sweden)

    Shu-Kun Lin

    2013-01-01

    Full Text Available Microwave and millimeter-wave remote sensing techniques are fast becoming a necessity in many aspects of security as detection and classification of objects or intruders becomes more difficult. This groundbreaking resource offers you expert guidance in this burgeoning area. It provides you with a thorough treatment of the principles of microwave and millimeter-wave remote sensing for security applications, as well as practical coverage of the design of radiometer, radar, and imaging systems. You learn how to design active and passive sensors for intruder detection, concealed object detection, and human activity classification. This detailed book presents the fundamental concepts practitioners need to understand, including electromagnetic wave propagation in free space and in media, antenna theory, and the principles of receiver design. You find in-depth discussions on the interactions of electromagnetic waves with human tissues, the atmosphere and various building and clothing materials. This timely volume explores recently developed detection techniques, such as micro-Doppler radar signatures and correlation radiometry. The book is supported with over 200 illustrations and 1,135 equations.

  20. A physical based equivalent circuit modeling approach for ballasted InP DHBT multi-finger devices at millimeter-wave frequencies

    DEFF Research Database (Denmark)

    Midili, Virginio; Squartecchia, Michele; Johansen, Tom Keinicke

    2016-01-01

    Multifinger InP DHBTs can be designed with a ballasting resistor to improve power capability. However accurate modeling is needed to predict high frequency behavior of the device. This paper presents two distinct modeling approaches: one based on EM simulations and one based on a physical...

  1. Optics assembly for high power laser tools

    Science.gov (United States)

    Fraze, Jason D.; Faircloth, Brian O.; Zediker, Mark S.

    2016-06-07

    There is provided a high power laser rotational optical assembly for use with, or in high power laser tools for performing high power laser operations. In particular, the optical assembly finds applications in performing high power laser operations on, and in, remote and difficult to access locations. The optical assembly has rotational seals and bearing configurations to avoid contamination of the laser beam path and optics.

  2. Review of Power System Stability with High Wind Power Penetration

    DEFF Research Database (Denmark)

    Hu, Rui; Hu, Weihao; Chen, Zhe

    2015-01-01

    This paper presents an overview of researches on power system stability with high wind power penetration including analyzing methods and improvement approaches. Power system stability issues can be classified diversely according to different considerations. Each classified issue has special...... analyzing methods and stability improvement approaches. With increasing wind power penetration, system balancing and the reduced inertia may cause a big threaten for stable operation of power systems. To mitigate or eliminate the wind impacts for high wind penetration systems, although the practical...... and reliable choices currently are the strong outside connections or sufficient reserve capacity constructions, many novel theories and approaches are invented to investigate the stability issues, looking forward to an extra-high penetration or totally renewable resource based power systems. These analyzing...

  3. Millimeter-wave irradiation heating for operation of doped CeO2 electrolyte-supported single solid oxide fuel cell

    Science.gov (United States)

    Che Abdullah, Salmie Suhana Binti; Teranishi, Takashi; Hayashi, Hidetaka; Kishimoto, Akira

    2018-01-01

    High operation temperature of solid oxide fuel cell (SOFC) results in high cell and operation cost, time consuming and fast cell degradation. Developing high performance SOFC that operates at lower temperature is required. Here we demonstrate 24 GHz microwave as a rapid heating source to replace conventional heating method for SOFC operation using 20 mol% Sm doped CeO2 electrolyte-supported single cell. The tested cell shows improvement of 62% in maximum power density at 630 °C under microwave heating. This improvement governs by bulk conductivity of the electrolyte. Investigation of ionic transference number reveals that the value is unchanged under microwave irradiation, confirming the charge carrier is dominated by oxygen ion species. This work shows a potential new concept of high performance as well as cost and energy effective SOFC.

  4. Electronic DC transformer with high power density

    NARCIS (Netherlands)

    Pavlovský, M.

    2006-01-01

    This thesis is concerned with the possibilities of increasing the power density of high-power dc-dc converters with galvanic isolation. Three cornerstones for reaching high power densities are identified as: size reduction of passive components, reduction of losses particularly in active components

  5. High Power Fiber Laser Test Bed

    Data.gov (United States)

    Federal Laboratory Consortium — This facility, unique within DoD, power-combines numerous cutting-edge fiber-coupled laser diode modules (FCLDM) to integrate pumping of high power rare earth-doped...

  6. High power RF solid state power amplifier system

    Science.gov (United States)

    Sims, III, William Herbert (Inventor); Chavers, Donald Gregory (Inventor); Richeson, James J. (Inventor)

    2011-01-01

    A high power, high frequency, solid state power amplifier system includes a plurality of input multiple port splitters for receiving a high-frequency input and for dividing the input into a plurality of outputs and a plurality of solid state amplifier units. Each amplifier unit includes a plurality of amplifiers, and each amplifier is individually connected to one of the outputs of multiport splitters and produces a corresponding amplified output. A plurality of multiport combiners combine the amplified outputs of the amplifiers of each of the amplifier units to a combined output. Automatic level control protection circuitry protects the amplifiers and maintains a substantial constant amplifier power output.

  7. High Power Performance of Rod Fiber Amplifiers

    DEFF Research Database (Denmark)

    Johansen, Mette Marie; Michieletto, Mattia; Kristensen, Torben

    2015-01-01

    An improved version of the DMF rod fiber is tested in a high power setup delivering 360W of stable signal power. Multiple testing degrades the fiber and transverse modal instability threshold from >360W to ~290W.......An improved version of the DMF rod fiber is tested in a high power setup delivering 360W of stable signal power. Multiple testing degrades the fiber and transverse modal instability threshold from >360W to ~290W....

  8. High Power laser power conditioning system new discharge circuit research

    CERN Document Server

    Li Yi; Peng Han Sheng; Zhou Pei Zhang; Zheng Wan Guo; Guo Lang Fu; Chen Li Hua; Chen De Hui; Lai Gui You; Luan Yong Ping

    2002-01-01

    The new discharge circuit of power conditioning system for high power laser is studied. The theoretical model of the main discharge circuit is established. The pre-ionization circuit is studied in experiment. In addition, the explosion energy of the new large xenon lamp is successfully measured. The conclusion has been applied to 4 x 2 amplifier system

  9. State-of-the-art of high power gyro-devices and free electron masers. Update 2015

    Energy Technology Data Exchange (ETDEWEB)

    Thumm, Manfred [Karlsruher Institut fuer Technologie (KIT), Eggenstein-Leopoldshafen (Germany). Inst. fuer Hochleistungsimpuls- und Mikrowellentechnik, Programm Fusion

    2016-07-01

    Gyrotron oscillators (gyromonotrons) are mainly used as high power millimeter wave sources for electron cyclotron resonance heating (ECRH), electron cyclotron current drive (ECCD), stability control and diagnostics of magnetically confined plasmas for generation of energy by controlled thermonuclear fusion. The maximum pulse length of commercially available 140 GHz, megawatt- class gyrotrons employing synthetic diamond output windows is 30 minutes (CPI and European KIT-CRPP-TED collaboration). The world record parameters of the European megawatt-class 140 GHz gyrotron are: 0.92 MW output power at 30 min. pulse duration, 97.5% Gaussian mode purity and 44% efficiency, employing a single-stage depressed collector (SDC) for energy recovery. A maximum output power of 1.5 MW in 4.0 s pulses at 45% efficiency was generated with the JAEA-TOSHIBA 110 GHz gyrotron. The Japan 170 GHz ITER gyrotron achieved 1 MW, 800 s at 55% efficiency and holds the energy world record of 2.88 GJ (0.8 MW, 60 min.) and the efficiency record of 57% for tubes with an output power of more than 0.5 MW. The Russian 170 GHz ITER gyrotron achieved 0.99 (1.2) MW with a pulse duration of 1000 (100) s and 53 (53) % efficiency. The prototype tube of the European 2 MW, 170 GHz coaxial-cavity gyrotron achieved in short pulses the record power of 2.1 MW at 46% efficiency and 96% Gaussian mode purity. Gyrotrons with pulsed magnet for various short-pulse applications deliver P{sub out}=210 kW with τ=20 μs at frequencies up to 670 GHz (η≅20%), P{sub out}=5.3 kW at 1 THz (η=6.1%), and P{sub out}=0.5 kW at 1.3 THz (η=0.6%). Gyrotron oscillators have also been successfully used in materials processing. Such technological applications require gyrotrons with the following parameters: f ≥ 24 GHz, P{sub out}=4-50 kW, CW, η≥30%. This paper gives an update of the experimental achievements related to the development of high power gyrotron oscillators for long-pulse or CW operation and pulsed gyrotrons for

  10. A review of InP/InAlAs/InGaAs based transistors for high frequency applications

    Science.gov (United States)

    Ajayan, J.; Nirmal, D.

    2015-10-01

    This paper presents an overview of the rapid progress being made in the development of InP based devices for high speed applications. Over the past few decades, major aero space industries have been developing InP based hetero structure devices like hetero junction bipolar transistors (HBTs) and high electron mobility transistors (HEMT) because of their low DC power due to excellent low voltage operation and milli-meter wave frequency performance even though its widespread use has been limited by high cost. InP based HBTs, MOSFETs and HEMTs have also been developed by commercial companies for applications in high speed fiber optic communications because InP based device technologies takes advantage of the intrinsic material properties such as high thermal conductivity, high electron mobility and low energy band gap for low voltage operation compared to silicon, silicon-germenium, and GaAs based semiconductor devices.

  11. CMOS 60-GHz and E-band power amplifiers and transmitters

    CERN Document Server

    Zhao, Dixian

    2015-01-01

    This book focuses on the development of design techniques and methodologies for 60-GHz and E-band power amplifiers and transmitters at device, circuit and layout levels. The authors show the recent development of millimeter-wave design techniques, especially of power amplifiers and transmitters, and presents novel design concepts, such as “power transistor layout” and “4-way parallel-series power combiner”, that can enhance the output power and efficiency of power amplifiers in a compact silicon area. Five state-of-the-art 60-GHz and E-band designs with measured results are demonstrated to prove the effectiveness of the design concepts and hands-on methodologies presented. This book serves as a valuable reference for circuit designers to develop millimeter-wave building blocks for future 5G applications.

  12. High-intensity coherent FIR radiation from sub-picosecond electron bunches

    Energy Technology Data Exchange (ETDEWEB)

    Kung, P.H.; Lihn, Hung-chi; Wiedemann, H.; Bocek, D.

    1994-01-01

    A facility to generate high-intensity, ultra-short pulses of broad-band far-infrared radiation has been assembled and tested at Stanford. The device uses sub-picosecond relativistic electron bunches to generate coherent radiation through transition or synchrotron radiation in the far-infrared (FIR) regime between millimeter waves and wavelengths of about 100 {mu}m and less. Experimental results show a peak radiation power of greater than 0.33 MW within a micro-bunch and an average FIR radiation power of 4 mW. The average bunch length of 2856 micro-bunches within a 1 {mu}sec macro-pulse is estimated to be about 480 sec. Simulations experimental setup and results will be discussed.

  13. Power Amplifier Module with 734-mW Continuous Wave Output Power

    Science.gov (United States)

    Fung, King Man; Samoska, Lorene A.; Kangaslahti, Pekka P.; Lamgrigtsen, Bjorn H.; Goldsmith, Paul F.; Lin, Robert H.; Soria, Mary M.; Cooperrider, Joelle T.; Micovic, Moroslav; Kurdoghlian, Ara

    2010-01-01

    Research findings were reported from an investigation of new gallium nitride (GaN) monolithic millimeter-wave integrated circuit (MMIC) power amplifiers (PAs) targeting the highest output power and the highest efficiency for class-A operation in W-band (75-110 GHz). W-band PAs are a major component of many frequency multiplied submillimeter-wave LO signal sources. For spectrometer arrays, substantial W-band power is required due to the passive lossy frequency multipliers-to generate higher frequency signals in nonlinear Schottky diode-based LO sources. By advancing PA technology, the LO system performance can be increased with possible cost reductions compared to current GaAs PAs. High-power, high-efficiency GaN PAs are cross-cutting and can enable more efficient local oscillator distribution systems for new astrophysics and planetary receivers and heterodyne array instruments. It can also allow for a new, electronically scannable solid-state array technology for future Earth science radar instruments and communications platforms.

  14. High power laser perforating tools and systems

    Science.gov (United States)

    Zediker, Mark S; Rinzler, Charles C; Faircloth, Brian O; Koblick, Yeshaya; Moxley, Joel F

    2014-04-22

    ystems devices and methods for the transmission of 1 kW or more of laser energy deep into the earth and for the suppression of associated nonlinear phenomena. Systems, devices and methods for the laser perforation of a borehole in the earth. These systems can deliver high power laser energy down a deep borehole, while maintaining the high power to perforate such boreholes.

  15. Packaging of high power semiconductor lasers

    CERN Document Server

    Liu, Xingsheng; Xiong, Lingling; Liu, Hui

    2014-01-01

    This book introduces high power semiconductor laser packaging design. The characteristics and challenges of the design and various packaging, processing, and testing techniques are detailed by the authors. New technologies, in particular thermal technologies, current applications, and trends in high power semiconductor laser packaging are described at length and assessed.

  16. Automated System Tests High-Power MOSFET's

    Science.gov (United States)

    Huston, Steven W.; Wendt, Isabel O.

    1994-01-01

    Computer-controlled system tests metal-oxide/semiconductor field-effect transistors (MOSFET's) at high voltages and currents. Measures seven parameters characterizing performance of MOSFET, with view toward obtaining early indication MOSFET defective. Use of test system prior to installation of power MOSFET in high-power circuit saves time and money.

  17. High-power optics lasers and applications

    CERN Document Server

    Apollonov, Victor V

    2015-01-01

    This book covers the basics, realization and materials for high power laser systems and high power radiation interaction with  matter. The physical and technical fundamentals of high intensity laser optics and adaptive optics and the related physical processes in high intensity laser systems are explained. A main question discussed is: What is power optics? In what way is it different from ordinary optics widely used in cameras, motion-picture projectors, i.e., for everyday use? An undesirable consequence of the thermal deformation of optical elements and surfaces was discovered during studies of the interaction with powerful incident laser radiation. The requirements to the fabrication, performance and quality of optical elements employed within systems for most practical applications are also covered. The high-power laser performance is generally governed by the following: (i) the absorption of incident optical radiation (governed primarily by various absorption mechanisms), (ii) followed by a temperature ...

  18. A Novel Multimode Waveguide Coupler for Accurate Power Measurement of Traveling Wave Tube Harmonic Frequencies

    Science.gov (United States)

    Wintucky, Edwin G.; Simons, Rainee N.

    2014-01-01

    This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler fabricated from two dissimilar waveguides is capable of isolating the power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT). In addition to accurate power measurements at harmonic frequencies, a potential application of the MDC is in the design of a beacon source for atmospheric propagation studies at millimeter-wave frequencies.

  19. Evaluation of high-voltage, high-power, solid-state remote power controllers for amps

    Science.gov (United States)

    Callis, Charles P.

    1987-01-01

    The Electrical Power Branch at Marshall Space Flight Center has a Power System Development Facility where various power circuit breadboards are tested and evaluated. This project relates to the evaluation of a particular remote power controller (RPC) energizing high power loads. The Facility equipment permits the thorough testing and evaluation of high-voltage, high-power solid-state remote power controllers. The purpose is to evaluate a Type E, 30 Ampere, 200 V dc remote power controller. Three phases of the RPC evaluation are presented. The RPC is evaluated within a low-voltage, low-power circuit to check its operational capability. The RPC is then evaluated while performing switch/circuit breaker functions within a 200 V dc, 30 Ampere power circuit. The final effort of the project relates to the recommended procedures for installing these RPC's into the existing Autonomously Managed Power System (AMPS) breadboard/test facility at MSFC.

  20. High power ultrashort pulse lasers

    Energy Technology Data Exchange (ETDEWEB)

    Perry, M.D.

    1994-10-07

    Small scale terawatt and soon even petawatt (1000 terawatt) class laser systems are made possible by application of the chirped-pulse amplification technique to solid-state lasers combined with the availability of broad bandwidth materials. These lasers make possible a new class of high gradient accelerators based on the large electric fields associated with intense laser-plasma interactions or from the intense laser field directly. Here, we concentrate on the laser technology to produce these intense pulses. Application of the smallest of these systems to the production of high brightness electron sources is also introduced.

  1. Low Power Design with High-Level Power Estimation and Power-Aware Synthesis

    CERN Document Server

    Ahuja, Sumit; Shukla, Sandeep Kumar

    2012-01-01

    Low-power ASIC/FPGA based designs are important due to the need for extended battery life, reduced form factor, and lower packaging and cooling costs for electronic devices. These products require fast turnaround time because of the increasing demand for handheld electronic devices such as cell-phones, PDAs and high performance machines for data centers. To achieve short time to market, design flows must facilitate a much shortened time-to-product requirement. High-level modeling, architectural exploration and direct synthesis of design from high level description enable this design process. This book presents novel research techniques, algorithms,methodologies and experimental results for high level power estimation and power aware high-level synthesis. Readers will learn to apply such techniques to enable design flows resulting in shorter time to market and successful low power ASIC/FPGA design. Integrates power estimation and reduction for high level synthesis, with low-power, high-level design; Shows spec...

  2. Heatsink Design of High Power Converter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Ki [Chungang University (Korea)

    1999-04-01

    Various ways of designing heat sink are available for commercial high power converters and among them, the method of air cooling is the most popular and practical method than any other ones. In this paper, a practical method of cooling high power converter, which includes a method of reducing noise and vibration caused by the fan and a method of estimating the gap and contact resistances existing between the thyristor and heat sink, is presented. Finally, the heat transfer analysis and implementation methods of heat sink for high power converter is presented. (author). 14 refs., 11 figs., 3 tabs.

  3. High current and high power superconducting rectifiers

    NARCIS (Netherlands)

    ten Kate, Herman H.J.; Bunk, P.B.; Britton, R.B.; van de Klundert, L.J.M.

    1981-01-01

    Results on three experimental superconducting rectifiers are reported. Two of them are 1 kA low frequency flux pumps, one thermally and magnetically switched. The third is a low-current high-frequency magnetically switched rectifier which can use the mains directly.

  4. An introduction to high power microwaves

    Science.gov (United States)

    Benford, James; Swegle, John

    1992-02-01

    The area of high power microwaves has emerged in recent years as a new technology allowing new applications and offering innovative approaches to existing applications. The great leap in microwave power levels has been driven by a mix of sources that either push conventional microwave device physics in new directions or employ altogether new interaction mechanisms. Running counter to the trend in conventional microwave electronics toward miniaturization with solid-state devices intrinsically limited in their peak power capability, high power microwave generation taps the immense power and energy reservoirs of modern intense relativistic electron beam technology. The term high power microwaves (HPM) is used to denote devices that exceed 100 MW in peak power and span the cm- and mm-wave range of frequencies between 1 and 300 GHz. This definition is arbitrary, but does cleanly divide the conventional microwave devices, which do not exceed 100 MW, from a collection of microwave-generating devices that have now reached powers as high as 15 GW.

  5. Driver Circuit For High-Power MOSFET's

    Science.gov (United States)

    Letzer, Kevin A.

    1991-01-01

    Driver circuit generates rapid-voltage-transition pulses needed to switch high-power metal oxide/semiconductor field-effect transistor (MOSFET) modules rapidly between full "on" and full "off". Rapid switching reduces time of overlap between appreciable current through and appreciable voltage across such modules, thereby increasing power efficiency.

  6. Highly-efficient high-power pumps for fiber lasers

    Science.gov (United States)

    Gapontsev, V.; Moshegov, N.; Berezin, I.; Komissarov, A.; Trubenko, P.; Miftakhutdinov, D.; Berishev, I.; Chuyanov, V.; Raisky, O.; Ovtchinnikov, A.

    2017-02-01

    We report on high efficiency multimode pumps that enable ultra-high efficiency high power ECO Fiber Lasers. We discuss chip and packaged pump design and performance. Peak out-of-fiber power efficiency of ECO Fiber Laser pumps was reported to be as high as 68% and was achieved with passive cooling. For applications that do not require Fiber Lasers with ultimate power efficiency, we have developed passively cooled pumps with out-of-fiber power efficiency greater than 50%, maintained at operating current up to 22A. We report on approaches to diode chip and packaged pump design that possess such performance.

  7. High power density carbonate fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Yuh, C.; Johnsen, R.; Doyon, J.; Allen, J. [Energy Research Corp., Danbury, CT (United States)

    1996-12-31

    Carbonate fuel cell is a highly efficient and environmentally clean source of power generation. Many organizations worldwide are actively pursuing the development of the technology. Field demonstration of multi-MW size power plant has been initiated in 1996, a step toward commercialization before the turn of the century, Energy Research Corporation (ERC) is planning to introduce a 2.85MW commercial fuel cell power plant with an efficiency of 58%, which is quite attractive for distributed power generation. However, to further expand competitive edge over alternative systems and to achieve wider market penetration, ERC is exploring advanced carbonate fuel cells having significantly higher power densities. A more compact power plant would also stimulate interest in new markets such as ships and submarines where space limitations exist. The activities focused on reducing cell polarization and internal resistance as well as on advanced thin cell components.

  8. High power regenerative laser amplifier

    Science.gov (United States)

    Miller, John L.; Hackel, Lloyd A.; Dane, Clifford B.; Zapata, Luis E.

    1994-01-01

    A regenerative amplifier design capable of operating at high energy per pulse, for instance, from 20-100 Joules, at moderate repetition rates, for instance from 5-20 Hertz is provided. The laser amplifier comprises a gain medium and source of pump energy coupled with the gain medium; a Pockels cell, which rotates an incident beam in response to application of a control signal; an optical relay system defining a first relay plane near the gain medium and a second relay plane near the rotator; and a plurality of reflectors configured to define an optical path through the gain medium, optical relay and Pockels cell, such that each transit of the optical path includes at least one pass through the gain medium and only one pass through the Pockels cell. An input coupler, and an output coupler are provided, implemented by a single polarizer. A control circuit coupled to the Pockels cell generates the control signal in timed relationship with the input pulse so that the input pulse is captured by the input coupler and proceeds through at least one transit of the optical path, and then the control signal is applied to cause rotation of the pulse to a polarization reflected by the polarizer, after which the captured pulse passes through the gain medium at least once more and is reflected out of the optical path by the polarizer before passing through the rotator again to provide an amplified pulse.

  9. Piezoelectric Transformers for a High Power Module

    National Research Council Canada - National Science Library

    Ezaki, T

    2003-01-01

    .... Here, in order to obtain compact and high-power AC-DC adaptors, we explored suitable designs for a multi-layered piezoelectric transformer, by taking into account the effect of the mechanical quality...

  10. High Power Helicon Plasma Propulsion Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed work seeks to develop and optimize an electrode-less plasma propulsion system that is based on a high power helicon (HPH) that is being developed...

  11. High Power Helicon Plasma Propulsion Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A new thruster has been conceived and tested that is based on a high power helicon (HPH) plasma wave. In this new method of propulsion, an antenna generates and...

  12. The NASA CSTI high capacity power project

    Science.gov (United States)

    Winter, J.; Dudenhoefer, J.; Juhasz, A.; Schwarze, G.; Patterson, R.; Ferguson, D.; Titran, R.; Schmitz, P.; Vandersande, J.

    1992-01-01

    The SP-100 Space Nuclear Power Program was established in 1983 by DOD, DOE, and NASA as a joint program to develop technology for military and civil applications. Starting in 1986, NASA has funded a technology program to maintain the momentum of promising aerospace technology advancement started during Phase 1 of SP-100 and to strengthen, in key areas, the chances for successful development and growth capability of space nuclear reactor power systems for a wide range of future space applications. The elements of the Civilian Space Technology Initiative (CSTI) High Capacity Power Project include Systems Analysis, Stirling Power Conversion, Thermoelectric Power Conversion, Thermal Management, Power Management, Systems Diagnostics, Environmental Interactions, and Material/Structural Development. Technology advancement in all elements is required to provide the growth capability, high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems. The overall project will develop and demonstrate the technology base required to provide a wide range of modular power systems compatible with the SP-100 reactor which facilitates operation during lunar and planetary day/night cycles as well as allowing spacecraft operation at any attitude or distance from the sun. Significant accomplishments in all of the project elements will be presented, along with revised goals and project timelines recently developed.

  13. High mobility polymer gated organic field effect transistor using zinc ...

    Indian Academy of Sciences (India)

    Mater. Sci., Vol. 37, No. 1, February 2014, pp. 95–99. c Indian Academy of Sciences. High mobility polymer gated organic field effect transistor using zinc phthalocyanine. K R RAJESH. ∗. , V KANNAN, M R KIM, Y S CHAE and J K RHEE. Millimeter- Wave Innovation Technology Research Centre (MINT), Dongguk University,.

  14. Protection Related to High-power Targets

    CERN Document Server

    Plum, M.A.

    2016-01-01

    Target protection is an important part of machine protection. The beam power in high-intensity accelerators is high enough that a single wayward pulse can cause serious damage. Today's high-power targets operate at the limit of available technology, and are designed for a very narrow range of beam parameters. If the beam pulse is too far off centre, or if the beam size is not correct, or if the beam density is too high, the target can be seriously damaged. We will start with a brief introduction to high-power targets and then move to a discussion of what can go wrong, and what are the risks. Next we will discuss how to control the beam-related risk, followed by examples from a few different accelerator facilities. We will finish with a detailed example of the Oak Ridge Spallation Neutron Source target tune up and target protection.

  15. High power diode laser Master Oscillator-Power Amplifier (MOPA)

    Science.gov (United States)

    Andrews, John R.; Mouroulis, P.; Wicks, G.

    1994-01-01

    High power multiple quantum well AlGaAs diode laser master oscillator - power amplifier (MOPA) systems were examined both experimentally and theoretically. For two pass operation, it was found that powers in excess of 0.3 W per 100 micrometers of facet length were achievable while maintaining diffraction-limited beam quality. Internal electrical-to-optical conversion efficiencies as high as 25 percent were observed at an internal amplifier gain of 9 dB. Theoretical modeling of multiple quantum well amplifiers was done using appropriate rate equations and a heuristic model of the carrier density dependent gain. The model gave a qualitative agreement with the experimental results. In addition, the model allowed exploration of a wider design space for the amplifiers. The model predicted that internal electrical-to-optical conversion efficiencies in excess of 50 percent should be achievable with careful system design. The model predicted that no global optimum design exists, but gain, efficiency, and optical confinement (coupling efficiency) can be mutually adjusted to meet a specific system requirement. A three quantum well, low optical confinement amplifier was fabricated using molecular beam epitaxial growth. Coherent beam combining of two high power amplifiers injected from a common master oscillator was also examined. Coherent beam combining with an efficiency of 93 percent resulted in a single beam having diffraction-limited characteristics. This beam combining efficiency is a world record result for such a system. Interferometric observations of the output of the amplifier indicated that spatial mode matching was a significant factor in the less than perfect beam combining. Finally, the system issues of arrays of amplifiers in a coherent beam combining system were investigated. Based upon experimentally observed parameters coherent beam combining could result in a megawatt-scale coherent beam with a 10 percent electrical-to-optical conversion efficiency.

  16. Advances in Very High Frequency Power Conversion

    DEFF Research Database (Denmark)

    Kovacevic, Milovan

    . Excellent performance and small size of magnetic components and capacitors at very high frequencies, along with constant advances in performance of power semiconductor devices, suggests a sizable shift in consumer power supplies market into this area in the near future. To operate dc-dc converter power...... devices at very high frequencies, switching loss needs to reduced or eliminated, as it would become prohibitively large. In addition, as the frequency increases, hard-switched gate driving becomes less and less of an option, as it embodies the same loss mechanism. A low-loss gate drive methods may need...... drive solution, which is applicable in cases when there are at least two power stages, and with minimal additional hardware requirements. It is experimentally confirmed that the method is suitable for both parallel and serial input configurations. Compared to state-of-the-art solutions, the proposed...

  17. The NASA CSTI High Capacity Power Program

    Science.gov (United States)

    Winter, Jerry M.

    1991-01-01

    NASA's Civil Space Technology Initiative (CSTI) has as its primary goal the improvement of space nuclear power-related technologies and their interactions with the given mission environment. The CSTI High Capacity Power Program supports and advances all nonnuclear aspects of the national SP-100 Space Nuclear Reactor Program, including the demonstration of a 1050 K Stirling Space Power System capable of employing the full output capability of the SP-100 reactor. Thermoelectric technology capable of reaching Z values of 0.001/K with SiGe/GaP will be demonstrated in the course of the program.

  18. High-voltage power supply unit

    CERN Document Server

    Garipov, G K; Silaev, A A; Shirokov, A V

    2002-01-01

    A unit comprising four high-voltage power sources (HPS) is designed for power supply of four independent photomultipliers. Each HPS comprises a pulse-width modulator, digital-to-analog converter, base voltage source and digital interface. HPS unit supplies up to 2000 V output voltage, up to 2.5 mA current and long-term stability equal to +- 0.03%

  19. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  20. The Jefferson Lab High Power Light Source

    Energy Technology Data Exchange (ETDEWEB)

    James R. Boyce

    2006-01-01

    Jefferson Lab has designed, built and operated two high average power free-electron lasers (FEL) using superconducting RF (SRF) technology and energy recovery techniques. Between 1999-2001 Jefferson Lab operated the IR Demo FEL. This device produced over 2 kW in the mid-infrared, in addition to producing world record average powers in the visible (50 W), ultraviolet (10 W) and terahertz range (50 W) for tunable, short-pulse (< ps) light. This FEL was the first high power demonstration of an accelerator configuration that is being exploited for a number of new accelerator-driven light source facilities that are currently under design or construction. The driver accelerator for the IR Demo FEL uses an Energy Recovered Linac (ERL) configuration that improves the energy efficiency and lowers both the capital and operating cost of such devices by recovering most of the power in the spent electron beam after optical power is extracted from the beam. The IR Demo FEL was de-commissioned in late 2001 for an upgraded FEL for extending the IR power to over 10 kW and the ultraviolet power to over 1 kW. The FEL Upgrade achieved 10 kW of average power in the mid-IR (6 microns) in July of 2004, and its IR operation currently is being extended down to 1 micron. In addition, we have demonstrated the capability of on/off cycling and recovering over a megawatt of electron beam power without diminishing machine performance. A complementary UV FEL will come on-line within the next year. This paper presents a summary of the FEL characteristics, user community accomplishments with the IR Demo, and planned user experiments.

  1. High Power Diode Lasers Technology and Applications

    CERN Document Server

    Bachmann, Friedrich; Poprawe, Reinhart

    2007-01-01

    In a very comprehensive way this book covers all aspects of high power diode laser technology for materials processing. Basics as well as new application oriented results obtained in a government funded national German research project are described in detail. Along the technological chain after a short introduction in the second chapter diode laser bar technology is discussed regarding structure, manufacturing technology and metrology. The third chapter illuminates all aspects of mounting and cooling, whereas chapter four gives wide spanning details on beam forming, beam guiding and beam combination, which are essential topics for incoherently coupled multi-emitter based high power diode lasers. Metrology, standards and safety aspects are the theme of chapter five. As an outcome of all the knowledge from chapter two to four various system configurations of high power diode lasers are described in chapter six; not only systems focussed on best available beam quality but especially also so called "modular" set...

  2. Design and development of high voltage high power operational ...

    Indian Academy of Sciences (India)

    systems and the electron deflection systems. Power operational amplifiers have ... approach is cost and availability of high voltage devices in chip form. 2.2 Amplifier with opamp input stage .... power opamp, using chip passive components, semiconductor bare dice minimizes the size while increasing the reliability.

  3. Reduced filamentation in high power semiconductor lasers

    DEFF Research Database (Denmark)

    Skovgaard, Peter M. W.; McInerney, John; O'Brien, Peter

    1999-01-01

    High brightness semiconductor lasers have applications in fields ranging from material processing to medicine. The main difficulty associated with high brightness is that high optical power densities cause damage to the laser facet and thus require large apertures. This, in turn, results in spatio....... Experimentally, we generate transverse current profiles by using standard lithography to define a digitated contact pad. Experimental results confirm that the current density is significantly altered and show completely filamentation-free operation up to 34 times threshold....

  4. Advanced Output Coupling for High Power Gyrotrons

    Energy Technology Data Exchange (ETDEWEB)

    Read, Michael [Calabazas Creek Research, Inc., San Mateo, CA (United States); Ives, Robert Lawrence [Calabazas Creek Research, Inc., San Mateo, CA (United States); Marsden, David [Calabazas Creek Research, Inc., San Mateo, CA (United States); Collins, George [Calabazas Creek Research, Inc., San Mateo, CA (United States); Temkin, Richard [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Guss, William [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Lohr, John [General Atomics, La Jolla, CA (United States); Neilson, Jeffrey [Lexam Research, Redwood City, CA (United States); Bui, Thuc [Calabazas Creek Research, Inc., San Mateo, CA (United States)

    2016-11-28

    The Phase II program developed an internal RF coupler that transforms the whispering gallery RF mode produced in gyrotron cavities to an HE11 waveguide mode propagating in corrugated waveguide. This power is extracted from the vacuum using a broadband, chemical vapor deposited (CVD) diamond, Brewster angle window capable of transmitting more than 1.5 MW CW of RF power over a broad range of frequencies. This coupling system eliminates the Mirror Optical Units now required to externally couple Gaussian output power into corrugated waveguide, significantly reducing system cost and increasing efficiency. The program simulated the performance using a broad range of advanced computer codes to optimize the design. Both a direct coupler and Brewster angle window were built and tested at low and high power. Test results confirmed the performance of both devices and demonstrated they are capable of achieving the required performance for scientific, defense, industrial, and medical applications.

  5. Experimental results of a sheet-beam, high power, FEL amplifier with application to magnetic fusion research

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, S.; Destler, W.W.; Granatstein, V.L. [Univ. of Maryland, College Park, MD (United States)] [and others

    1995-12-31

    The experimental study of sheet-beam FELs as candidate millimeter-wave sources for heating magnetic fusion plasmas has achieved a major milestone. In a proof-of-principle, pulsed experiment, saturated FEL amplifier operation was achieved with 250 kW of output power at 86 GHz. Input microwave power was 1 kW, beam voltage was 450 kV and beam current was 17 A. The planar wiggler had a peak value of 3.8 kG, a period of 0.96 cm and was 71 cm long. The linear gain of 30 dB, saturated gain of 24 dB and saturated efficiency of 3% all are in good agreement with theoretical prediction. Follow-on work would include development of a thermionic sheet-beam electron-gun compatible with CW FEL operation, adding a section of tapered wiggler to increase the output power to levels in excess of 1 megawatt, and increasing the FEL frequency.

  6. Compact high-power terahertz radiation source

    Directory of Open Access Journals (Sweden)

    G. A. Krafft

    2004-06-01

    Full Text Available In this paper a new type of THz radiation source, based on recirculating an electron beam through a high gradient superconducting radio frequency cavity, and using this beam to drive a standard electromagnetic undulator on the return leg, is discussed. Because the beam is recirculated and not stored, short bunches may be produced that radiate coherently in the undulator, yielding exceptionally high average THz power for relatively low average beam power. Deceleration from the coherent emission, and the detuning it causes, limits the charge-per-bunch possible in such a device.

  7. Germanate Glass Fiber Lasers for High Power

    Science.gov (United States)

    2016-01-04

    AFRL-AFOSR-JP-TR-2016-0020 Germanate glass fiber lasers for high power David Lancaster THE UNIVERSITY OF ADELAIDE Final Report 01/04/2016...COVERED (From - To) 01-07-2014 to 30-06-2015 4. TITLE AND SUBTITLE Germanate glass fiber lasers for high power 5a.  CONTRACT NUMBER 5b.  GRANT NUMBER...germanate based glasses with a specific focus on glass stability during thermal-cycling which is representative of the steps required to fabricate a doped

  8. High impact data visualization with Power View, Power Map, and Power BI

    CERN Document Server

    Aspin, Adam

    2014-01-01

    High Impact Data Visualization with Power View, Power Map, and Power BI helps you take business intelligence delivery to a new level that is interactive, engaging, even fun, all while driving commercial success through sound decision-making. Learn to harness the power of Microsoft's flagship, self-service business intelligence suite to deliver compelling and interactive insight with remarkable ease. Learn the essential techniques needed to enhance the look and feel of reports and dashboards so that you can seize your audience's attention and provide them with clear and accurate information. Al

  9. LIDAR and Millimeter-Wave Cloud RADAR (MWCR) techniques for joint observations of cirrus in Shouxian (32.56°N, 116.78°E), China

    Science.gov (United States)

    Bu, Lingbing; Pan, Honglin; Kumar, K. Raghavendra; Huang, Xingyou; Gao, Haiyang; Qin, Yanqiu; Liu, Xinbo; Kim, Dukhyeon

    2016-10-01

    Cirrus plays an important role in the regulation of the Earth-atmosphere radiation budget. The joint observation using both the LIght Detection And Ranging (LIDAR) and Millimeter-Wave Cloud RADAR (MWCR) was implemented in this study to obtain properties of cirrus at Atmospheric Radiation Measurement (ARM) mobile facility in Shouxian (32.56°N, 116.78°E, 21 m above sea level), China during May-December 2008. We chose the simultaneous measurements of LIDAR and MWCR with effective data days, and the days must with cirrus. Hence, the cirrus properties based on 37 days of data between October 18th and December 13th, 2008 were studied in the present work. By comparing the LIDAR data with the MWCR data, we analyzed the detection capabilities of both instruments quantitatively for measuring the cirrus. The LIDAR cannot penetrate through the thicker cirrus with optical depth (τ) of more than 1.5, while the MWCR cannot sense the clouds with an optical depth of less than 0.3. Statistical analysis showed that the mean cloud base height (CBH) and cloud thickness (CT) of cirrus were 6.5±0.8 km and 2.1±1.1 km, respectively. Furthermore, we investigated three existing inversion methods for deriving the ice water content (IWC) by using the separate LIDAR, MWCR, and the combination of both, respectively. Based on the comparative analysis, a novel joint method was provided to obtain more accurate IWC. In this joint method, cirrus was divided into three different categories according to the optical depth (τ≤0.3, τ≥1.5, and 0.3<τ<1.5). Based on the joint method used in this study, the mean IWC was calculated by means of the statistics, which showed that the mean IWC of cirrus was 0.011±0.008 g m-3.

  10. Charging-discharging system with high power factor, high efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Soo; Joe, Kee Yeon; Byun, Young Bok; Koo, Heun Hoi [Korea Electrotechnology Research Institute (Korea, Republic of)

    1995-07-01

    This paper presents equipment for charging and discharging with high power factor and high efficiency. This equipment is consisted of 3{Phi} SPWM AC/DC converter for improving input current waveform and input power factor, and bidirectional DC/DC converter for electric isolation in the DC link Part. Therefore, Input power factor and the total efficiency in the proposed system can be increased more than in the conventional phase-controlled thyristor charging-discharging System. (author). 7 refs., 14 figs., 1 tab.

  11. Development of a high power femtosecond laser

    CSIR Research Space (South Africa)

    Neethling, PH

    2010-10-01

    Full Text Available The Laser Research Institute and the CSIR National Laser Centre are developing a high power femtosecond laser system in a joint project with a phased approach. The laser system consists of an fs oscillator and a regenerative amplifier. An OPCPA...

  12. High power Ar-Xe laser

    NARCIS (Netherlands)

    Witteman, W.J.; Gielkens, S.W.A.; Tskhai, V.N.; Peters, P.J.M.

    1998-01-01

    The discharge conditions of the multi-atmospheric e-beam sustained Ar-Xe laser are investigated. It is observed that the quasi-stationary period of a laser pulse depends on the e-beam current, the discharge power deposition and the gas density. The laser efficiency can be as high as 8%. The pulse

  13. High power beta electron device - Beyond betavoltaics.

    Science.gov (United States)

    Ayers, William M; Gentile, Charles A

    2018-01-01

    Developing watt level power sources with beta emitting radioisotopes has been limited by the inability to utilize high energy (> 100KeV) beta emitters at high radioisotope loadings without damaging the energy conversion materials. A new type of beta electron power source is described that removes those restrictions. The approach contains the radioisotope in a beta transparent titanium tube and confines beta electrons emitted through the tube wall to spiral trajectories around the tube with an axial magnetic field. The confined beta electrons dissipate energy though multiple interactions with surrounding excimer precursor gas atoms to efficiently generate photons. Photovoltaic cells convert the photons to electrical power. Since the beta electrons dissipate energy in the excimer precursor gas, the device can be loaded with more than 1013Bq of radioisotope to generate 100 milliwatt to watt levels of electrical power without damaging the device materials or degrading its performance. The power source can use a variety of beta radioisotopes and scales by stacking the devices. Copyright © 2017. Published by Elsevier Ltd.

  14. Laminar composite structures for high power actuators

    Science.gov (United States)

    Hobosyan, M. A.; Martinez, P. M.; Zakhidov, A. A.; Haines, C. S.; Baughman, R. H.; Martirosyan, K. S.

    2017-05-01

    Twisted laminar composite structures for high power and large-stroke actuators based on coiled Multi Wall Carbon Nanotube (MWNT) composite yarns were crafted by integrating high-density Nanoenergetic Gas Generators (NGGs) into carbon nanotube sheets. The linear actuation force, resulting from the pneumatic force caused by expanding gases confined within the pores of laminar structures and twisted carbon nanotube yarns, can be further amplified by increasing NGG loading and yarns twist density, as well as selecting NGG compositions with high energy density and large-volume gas generation. Moreover, the actuation force and power can be tuned by the surrounding environment, such as to increase the actuation by combustion in ambient air. A single 300-μm-diameter integrated MWNT/NGG coiled yarn produced 0.7 MPa stress and a contractile specific work power of up to 4.7 kW/kg, while combustion front propagated along the yarn at a velocity up to 10 m/s. Such powerful yarn actuators can also be operated in a vacuum, enabling their potential use for deploying heavy loads in outer space, such as to unfold solar panels and solar sails.

  15. Characterization of isolated 1-aza-adamantan-4-one (C9H13NO) from microwave, millimeter-wave and infrared spectroscopy supported by electronic structure calculations

    Science.gov (United States)

    Pirali, O.; Goubet, M.; Boudon, V.; D'Accolti, L.; Fusco, C.; Annese, C.

    2017-08-01

    We have synthesized 1-aza-adamantan-4-one (C9H13NO) starting from commercial 1,4-cyclohexanedionemonoethylene acetal and tosylmethylisocianide, following a procedure already described in the literature. The high degree of sample purity was demonstrated by gas chromatography and mass spectrometric measurements and its structure evidenced by 1H and 13C NMR spectroscopy. Among numerous interests in physical chemistry, this target molecule is of high relevance for mechanistic evaluation and the synthesis of novel pharmaceutical compounds. We present a thorough spectroscopic study of this molecule by gas phase vibrational and rotational spectroscopy. Accurate vibrational frequencies have been determined from infrared and far-infrared spectra. The pure rotational spectrum of the molecule has been recorded both by cavity-based Fourier transform microwave spectroscopy in the 2-20 GHz region by supersonically expanding the vapor pressure of the warm sample and by room-temperature absorption spectroscopy in the 140-220 GHz range. Accurate sets of rotational and centrifugal distortion parameters of 1-aza-adamantan-4-one in its ground state and in five vibrationally excited states have been derived from these measurements and compared to accurate quantum chemical calculations. The hyperfine parameters have been discussed in terms of molecular structure around the nitrogen quadrupole nucleus.

  16. High specific power lithium polymer rechargeable battery

    Energy Technology Data Exchange (ETDEWEB)

    Chu, M.Y.; De Jonghe, L.; Visco, S. [PolyPlus Battery Co., Berkeley, CA (United States)

    1996-11-01

    PolyPlus Battery Company (PPBC) is developing an advanced lithium polymer rechargeable battery based on its proprietary positive electrode. This battery offers high steady-state (> 250 W/kg) and peak power densities (3,000 W/kg), in a low cost and environmentally benign format. This PolyPlus lithium polymer battery also delivers high specific energy. The first generation battery has an energy density of 100 Wh/kg (120 Wh/l) and subsequent generations increases the performance in excess of 500 Wh/kg (600 Wh/l). The high power and energy densities, along with the low toxicity and low cost of materials used in the PolyPlus solid-state cell makes this battery exceptionally attractive for both hybrid and electric vehicle applications.

  17. Chirped-pulse Fourier transform millimeter-wave spectroscopy of ten vibrationally excited states of i-propyl cyanide: exploring the far-infrared region.

    Science.gov (United States)

    Arenas, Benjamin E; Gruet, Sébastien; Steber, Amanda L; Giuliano, Barbara M; Schnell, Melanie

    2017-01-18

    We report here further spectroscopic investigation of the astrochemically relevant molecule i-propyl cyanide. We observed and analysed the rotational spectra of the ground state of the molecule and ten vibrationally excited states with energies between 180-500 cm(-1). For this, we used a segmented W-band spectrometer (75-110 GHz) and performed the experiments under room temperature conditions. This approach thus provides access to high-resolution, pure rotational data of vibrational modes that occur in the far-infrared fingerprint region, and that can be difficult to access with other techniques. The obtained, extensive data set will support further astronomical searches and identifications, such as in warmer regions of the interstellar space where contributions from vibrationally excited states become increasingly relevant.

  18. Microwave and millimeter wave astrochemistry: Laboratory studies of transition metal-containing free radicals and spectroscopic observations of molecular interstellar environments

    Science.gov (United States)

    Adande, Gilles Rapotchombo

    Progress in our understanding of the chemical composition of the interstellar medium leans both on laboratory analyses of high resolution rotational spectra from molecules that may be present in these regions, and on radio astronomical observations of molecular tracers to constrain astrochemical models. Due to the thermodynamic conditions in outer space, some molecules likely to be found in interstellar regions in relevant abundances are open shell radicals. In a series of laboratory studies, the pure rotational spectra of the transition metal containing radicals sulfur species ScS, YS, VS and ZnSH were obtained for the first time. In addition to accurate and precise rest frequencies for these species, bonding characteristics were determined from fine and hyperfine molecular parameters. It was found that these sulfides have a higher degree of covalent bonding than their mostly ionic oxide counterparts. Isomers and isotope ratios are excellent diagnostic tools for a variety of astrochemical models. From radio observations of isotopes of nitrile species, the galactic gradient of 14N/15N was accurately established. A further study of this ratio in carbon rich asymptotic giant branch stars provided observational evidence for an unknown process in J type carbon stars, and highlighted the need to update stellar nucleosynthesis models. Proper radiative transfer modeling of the emission spectra of interstellar molecules can yield a wealth of information about the abundance and distribution of these species within the observed sources. To model the asymmetric emission of SO and SO2 in oxygen-rich supergiants, an in-house code was developed, and successfully applied to gain insight into circumstellar sulfur chemistry of VY Canis Majoris. It was concluded that current astrochemistry kinetic models, based on spherical symmetry assumptions, need to be revisited.

  19. Website Design Guidelines: High Power Distance and High Context Culture

    Directory of Open Access Journals (Sweden)

    Tanveer Ahmed

    2009-06-01

    Full Text Available This paper aims to address the question of offering a culturally adapted website for a local audience. So far, in the website design arena the vast majority of studies examined mainly Western and the American (low power distance and low context culture disregarding possible cultural discrepancies. This study fills this gap and explores the key cultural parameters that are likely to have an impact on local website design for Asian-Eastern culture high power distance and high context correlating with both Hofstede’s and Hall’s cultural dimensions. It also reviews how website localisation may be accomplished more effectively by extracting the guidelines from two different yet compatible cultural dimensions: high power distance and high context.

  20. MULTIPULSE - high resolution and high power in one TDEM system

    Science.gov (United States)

    Chen, Tianyou; Hodges, Greg; Miles, Philip

    2015-09-01

    An airborne time domain electromagnetic (TEM) system with high resolution and great depth of exploration is desired for geological mapping as well as for mineral exploration. The MULTIPULSE technology enables an airborne TEM system to transmit a high power pulse (a half-sine, for instance) and one or multiple low power pulse(s) (trapezoid or square) within a half-cycle. The high power pulse ensures good depth of exploration and the low power pulse allows a fast transmitter current turn off and earlier off-time measurement thus providing higher frequency signals, which allows higher near-surface resolution and better sensitivity to weak conductors. The power spectrum of the MULTIPULSE waveform comprising a half-sine and a trapezoid pulse clearly shows increased power in the higher frequency range (> ~2.3 kHz) compared to that of a single half-sine waveform. The addition of the low power trapezoid pulse extends the range of the sensitivity 10-fold towards the weak conductors, expanding the geological conductivity range of a system and increasing the scope of its applications. The MULTIPULSE technology can be applied to standard single-pulse airborne TEM systems on both helicopter and fixed-wing. We field tested the HELITEM MULTIPULSE system over a wire-loop in Iroquois Falls, demonstrating the different sensitivity of the high and low power pulses to the overburden and the wire-loop. We also tested both HELITEM and GEOTEM MULTIPULSE systems over a layered oil sand geologic setting in Fort McMurray, Alberta, Canada. The results show comparable shallow geologic resolution of the MULTIPULSE to that of the RESOLVE system while maintaining superior depth of exploration, confirming the increased geological conductivity range of a system employing MULTIPULSE compared to the standard single-pulse systems.

  1. High Power UV LED Industrial Curing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Karlicek, Robert, F., Jr; Sargent, Robert

    2012-05-14

    UV curing is a green technology that is largely underutilized because UV radiation sources like Hg Lamps are unreliable and difficult to use. High Power UV LEDs are now efficient enough to replace Hg Lamps, and offer significantly improved performance relative to Hg Lamps. In this study, a modular, scalable high power UV LED curing system was designed and tested, performing well in industrial coating evaluations. In order to achieve mechanical form factors similar to commercial Hg Lamp systems, a new patent pending design was employed enabling high irradiance at long working distances. While high power UV LEDs are currently only available at longer UVA wavelengths, rapid progress on UVC LEDs and the development of new formulations designed specifically for use with UV LED sources will converge to drive more rapid adoption of UV curing technology. An assessment of the environmental impact of replacing Hg Lamp systems with UV LED systems was performed. Since UV curing is used in only a small portion of the industrial printing, painting and coating markets, the ease of use of UV LED systems should increase the use of UV curing technology. Even a small penetration of the significant number of industrial applications still using oven curing and drying will lead to significant reductions in energy consumption and reductions in the emission of green house gases and solvent emissions.

  2. Power balance in highly loaded fluorescent lamps

    Energy Technology Data Exchange (ETDEWEB)

    Lister, G G [Osram Sylvania, 71 Cherry Hill Drive, Beverly, MA 01915 (United States); Curry, J J [National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899-8422 (United States); Lawler, J E [Department of Physics, University of Wisconsin, 1150 University Avenue, Madison, WI 53706 (United States)

    2004-11-21

    Discrepancies reported in the literature between numerical predictions and experimental measurements in low-pressure Hg discharges at high current densities are considered. Elements of a one-dimensional fluid model and recent spectroscopic and Langmuir probe measurements are combined in a semi-empirical way to individually examine components of the positive column power balance and the discharge conductivity. At a Hg vapour pressure of 0.81 Pa (6.1 mTorr) and a current density of 300 mA cm{sup -2}, previous discrepancies in the power balance and discharge conductivity are simultaneously resolved by assuming a higher electron density than that obtained from the Langmuir probe measurements. This conclusion is supported by independent measurements of ion density reported in a companion paper. The importance of radial cataphoresis under these conditions, particularly with regard to radiation transport, is highlighted. This work is of particular interest for the design of fluorescent lamps operating at high current densities.

  3. Methods for High Power EM Pulse Measurement

    Directory of Open Access Journals (Sweden)

    P. Fiala

    2006-12-01

    Full Text Available There are some suitable methods for the measurement of ultra-short solitary electromagnetic pulses that can be generated by high power pulsed generators. The measurement methods properties have to correspond to the fact whether we want to measure pulses of voltage, current or free-space electromagnetic wave. The need for specific measurement methods occurred by the development of high power microwave pulse generator. Applicable methods are presented in this paper. The method utilizing Faraday's induction law allows the measurement of generated current. For the same purpose the magneto-optic method can be utilized, with its advantages. For measurement of output microwave pulse of the generator the calorimetric method was designed and realized.

  4. Present and Future Trends in High Power Generation

    NARCIS (Netherlands)

    Heijster, R.M.E.M. van; Schouten, J.M.

    1995-01-01

    Modern warfare requires high levels of microwave power for various applications. Semiconductors are only suitable for low and medium power levels, for high power generation microwave tubes are still the most effective solution.

  5. Analysis of Highly Wind Power Integrated Power System model performance during Critical Weather conditions

    DEFF Research Database (Denmark)

    Basit, Abdul; Hansen, Anca Daniela; Sørensen, Poul Ejnar

    2014-01-01

    . For this purpose, the power system model has been developed that represents the relevant dynamic features of power plants and compensates for power imbalances caused by the forecasting error during critical weather conditions. The regulating power plan, as an input time series for the developed power system model......Secure power system operation of a highly wind power integrated power system is always at risk during critical weather conditions, e.g. in extreme high winds. The risk is even higher when 50% of the total electricity consumption has to be supplied by wind power, as the case for the future Danish......, is provided by the hour-ahead power balancing model, i.e. Simulation power Balancing model (SimBa. The regulating power plan is prepared from day-ahead power production plan and hour-ahead wind power forecast. The wind power (forecasts and available) are provided by the Correlated Wind power fluctuations (Cor...

  6. Millimeter Wave Radio Frequency Propagation Model Development

    Science.gov (United States)

    2014-08-28

    Anechoic Chamber .................................. 47  3.4.1  10 GHz Transmitting System...Propagation Losses ............................................................. 67  4.2  Experiment 2 - Quantifying Model Accuracy in an Anechoic Chamber ...44  Figure 20. Actual Footage of the Experiment at 10, 20, 30, and 40 GHz within the Anechoic Chamber

  7. Millimeter-Wave Spectroscopy of Phenyl Isocyanate

    Science.gov (United States)

    Schwarz, Cara E.; Amberger, Brent K.; Haenni, Benjamin C.; Esselman, Brian J.; Woods, R. Claude; McMahon, Robert J.

    2015-06-01

    Phenyl isocyanate (PhNCO) has been studied in the frequency range of 250-360 GHz, improving on rotational and centrifugal distortion constants based on previous spectroscopic studies between 4.7 and 40 GHz. Using the rigid rotor/centrifugal distortion model, many transitions have been assigned for the ground state (approximately 2200 transitions) and the fundamental of the -NCO torsional vibration (approximately 1500 transitions) for J values ranging between 140 and 210 and Kprolate values from 0 to 42. Beyond these K values, these two spectra show effects of perturbations with other vibrational states. Vibrational energy levels and vibration-rotation interaction constants were predicted using CFOUR at the CCSD(T)/ANO0 level. The two lowest energy excited vibrational modes are predicted to have energies of 47 cm-1 (-NCO torsion) and 95 cm-1 (in-plane -NCO wag). Fermi resonance between the first overtone of the -NCO torsional vibration (94 cm-1) and the fundamental of the in-plane -NCO wag has been observed in the spectra of these two states. Analysis for vibrationally excited states up to ~190 cm-1 is in progress. A. Bouchy and G. Roussy, Journal of Molecular Spectroscopy. 65 (1977), 395-404. W. Kasten and H. Dreizler, Z. Naturforsch. 42a (1987), 79-82.

  8. Electronically steerable millimeter-wave antennas

    Science.gov (United States)

    Varadan, Vijay K.; Varadan, Vasundara V.; Jose, K. A.; Kelly, James F.

    1994-05-01

    In this paper, electronically steerable microstrip and leaky wave antennas using tunable ferroelectric material are proposed. These antennas are lightweight, low volume, low profile, and conformal. They have low fabrication costs and are easily mass produced. They are thin and do not perturb the aerodynamics of a host automobile or aircraft. Linear, circular, and dual polarization are achieved with simple changes in feed position. Beam steering is accomplished by varying the relative phase between radiating elements. In planar array, both horizontal and vertical beam can be combined to provide full scanning capabilities. Tunable ceramic phase shifters are used in these antennas. In microstrip antennas, they are deposited as thin films on the feed lines whereas in the leaky wave antennas they have been used as a traveling waveguide with a ground plane on one side and metallic periodic grating on the opposite side. The dielectric properties of the ferroelectric material are changed by a bias voltage applied to the waveguide which in turn controls the leaky wave direction of the antenna. A simple experiment is presented which shows a good agreement with the theoretical prediction.

  9. Passive millimeter wave differential interference contrast polarimetry

    Science.gov (United States)

    Bernacki, Bruce E; Kelly, James F; Sheen, David M; Tedeschi, Jonathan R; Hall, Thomas E; Hatchell, Brian K; Valdez, Patrick; McMakin, Douglas L

    2014-04-29

    Differential polarization imaging systems include an axicon configured to provide a displacement of ray bundles associated with different image patches. The displaced ray bundles are directed to antenna horns and orthomode transducers so as to provide outputs correspond to orthogonal linear states of polarization (SOPs). The outputs are directed to a differential radiometer so that Stokes parameter differences between image patches can be obtained. The ray bundle displacements can be selected to correspond to a mechanical spacing of antenna horns. In some examples, ray bundle displacement corresponds to a displacement less than the diffraction limit.

  10. Millimeter Wave Induced BioEffects

    National Research Council Canada - National Science Library

    Blystone, Robert

    2006-01-01

    A baseline study determined the conditions of hemodynamic collapse in rats anesthetized with either ketamine plus xylazine or isoflurane alone and exposed to environmental heat at 42 or 43 degrees C...

  11. Epitaxial Hexagonal Ferrites for Millimeter Wave Devices.

    Science.gov (United States)

    1987-02-01

    project, LPE films of strontium hexaferrite (SrFe12019) were grown using PbO-B 20 3 solvent. The solution composition was 7 C 8344TCD/sn...which resulted in improved quality of barium hexaferrite films deposited on gallate spinel substrates (indium substituted magnesium gallium oxide...hexagonal ferrite films obtained by this method were more uniform and more strongly bonded to the substrate than films grown without the intermediary

  12. 3D-Printed Millimeter Wave Structures

    Science.gov (United States)

    2016-03-14

    demonstrates the resolution of the printer with a 10 micron nozzle. Figure 2: Measured loss tangent of SEBS and SBS samples. 3D - Printed Millimeter... 3D printing of styrene-butadiene-styrene (SBS) and styrene ethylene/butylene-styrene (SEBS) is used to demonstrate the feasibility of 3D - printed ...Additionally, a dielectric lens is printed which improves the antenna gain of an open-ended WR-28 waveguide from 7 to 8.5 dBi. Keywords: 3D printing

  13. Biological Effects of Millimeter-Wave Irradiation.

    Science.gov (United States)

    1982-12-01

    J., et al. Action d’un Rayonnement electromagnetique a’longuer d’onde millimetrique sur la croissance Bacterienne . Comptes Rendus Acad Sci (Paris...the conditions of the experiments were as follows. Eighteen-hour log-phase cultures of the test lysogen were pre- pared; the organisms were harvested...monolayer cultures . Bioelectromagnetics 2:123-140 (1981). 6. Stensaas, L. J., et al. Thermal and athermal bioeffects of microwave irradiation on

  14. Low Noise Millimeter Wave LNA Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Phase I effort will result in a low noise MMIC G-Band amplifier the covers the entire 165 to 193GHz frequency range. The amplifier will be designed using a 50nm...

  15. High Power Argon, Nitrogen Plasma Torches

    Science.gov (United States)

    Hakki, A.; Kashapov, N.; Sadikov, K.

    2017-11-01

    The paper describes a high power supply for Argon and Nitrogen plasma torches. A high frequency was used in order to drive the pulse width modulation circuit. The average output current consumption (AOCC) was modified from 20A up to 80A by increasing the pulse width from 2μsec up to 3μsec for Argon gas plasma torches. The (AOCC) was reduced from 70A down to 25A by increasing the pulse width from 6μsec up to 8μsec in the case of Nitrogen gas plasma torches.

  16. High Voltage Power Supply With High Output Current and Low Power Consumption for Photomultiplier Tubes

    Science.gov (United States)

    Cunha, José Paulo V. S.; Begalli, Marcia; Bellar, Maria Dias

    2012-04-01

    In some applications, photomultiplier tubes (PMTs) are powered by battery based circuits, where the available energy is severely limited. The most simple approach to design high voltage power supplies (HVPS) for PMTs has considered resistive voltage dividers in order to bias the dynodes. However, this approach usually results in high power losses and, consequently, this undermines the PMT performance. In this work, the proposed solution is the use of a power circuit based on the forward converter connected to a transformer built with several secondary windings. Each secondary voltage is rectified and filtered to eliminate voltage ripple. Each dynode voltage is supplied by a rectified secondary voltage. The proposed topology provides low power consumption as well as low sensitivity of the PMT gain with respect to the dynode currents. Taking into account the Waste Electrical and Electronic Equipment Directive (WEEE), this HVPS has been designed to allow the recycling of old PMTs.

  17. High peak power diode stacks for high energy lasers

    Science.gov (United States)

    Negoita, Viorel C.; Vethake, Thilo; Jiang, John; Roff, Robert; Shih, Ming; Duck, Richard; Bauer, Marc; Mite, Roberto; Boucke, Konstantin; Treusch, Georg

    2015-02-01

    High energy solid state lasers are being developed for fusion experiments and other research applications where high energy per pulse is required but the repetition rate is rather low, around 10Hz. We report our results on high peak power diode laser stacks used as optical pumps for these lasers. The stacks are based on 10 mm bars with 4 mm cavity length and 55% fill factor, with peak power exceeding 500 W per bar. These bars are stacked and mounted on a cooler which provides backside cooling and electrical insulation. Currently we mount 25 bars per cooler for a nominal peak power of 12.5 kW, but in principle the mounting scheme can be scaled to a different number of devices depending on the application. Pretesting of these bars before soldering on the cooler enables us to select devices with similar wavelength and thus we maintain tight control of the spectral width (FWHM less than 6 nm). Fine adjustments of the centroid wavelength can be done by means of temperature of the cooling fluid or bias current. The available wavelength range spans from 880 nm to 1000 nm, and the wavelength of the entire assembly of stacks can be controlled to within 0.5 nm of the target value, which makes these stacks suitable for pumping a variety of gain media. The devices are fast axis collimated, with over 95% power being collimated in 6 mrad (full angle). The slow axis divergence is 9° (full angle) for 95% power content.

  18. Industrial Applications of High Average Power FELS

    CERN Document Server

    Shinn, Michelle D

    2005-01-01

    The use of lasers for material processing continues to expand, and the annual sales of such lasers exceeds $1 B (US). Large scale (many m2) processing of materials require the economical production of laser powers of the tens of kilowatts, and therefore are not yet commercial processes, although they have been demonstrated. The development of FELs based on superconducting RF (SRF) linac technology provides a scaleable path to laser outputs above 50 kW in the IR, rendering these applications economically viable, since the cost/photon drops as the output power increases. This approach also enables high average power ~ 1 kW output in the UV spectrum. Such FELs will provide quasi-cw (PRFs in the tens of MHz), of ultrafast (pulsewidth ~ 1 ps) output with very high beam quality. This talk will provide an overview of applications tests by our facility's users such as pulsed laser deposition, laser ablation, and laser surface modification, as well as present plans that will be tested with our upgraded FELs. These upg...

  19. Optimized VCSELs for high-power arrays

    Science.gov (United States)

    Moench, Holger; Kolb, Johanna S.; Engelhardt, Andreas P.; Gerlach, Philipp; Jaeger, Roland; Pollmann-Retsch, Jens; Weichmann, Ulrich; Witzigmann, Bernd

    2014-02-01

    High-power VCSEL systems with multi kilowatt output power require a good electro-optical efficiency at the point of operation i.e. at elevated temperature. The large number of optimization parameters can be structured in a way that separates system and assembly considerations from the minimization of electrical and optical losses in the epitaxially grown structure. Temperature dependent functions for gain parameters, internal losses and injection efficiency are derived from a fit to experimental data. The empirical description takes into account diameter dependent effects like current spreading or temperature dependent ones like voltage drops over hetero-interfaces in the DBR mirrors. By evaluating experimental measurements of the light output and voltage characteristics over a large range of temperature and diameter, wafer-characteristic parameters are extracted allowing to predict the performance of VCSELs made from this material in any array and assembly configuration. This approach has several beneficial outcomes: Firstly, it gives a general description of a VCSEL independent of its geometry, mounting and detuning, secondly, insights into the structure and the underlying physics can be gained that lead to the improvement potential of the structure and thirdly the performance of the structure in arrays and modules can be predicted. Experimental results validate the approach and demonstrate the significantly improved VCSEL efficiency and the benefit in high power systems.

  20. Digitally Controlled High Availability Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    MacNair, David; /SLAC

    2008-09-25

    This paper reports the design and test results on novel topology, high-efficiency, and low operating temperature, 1,320-watt power modules for high availability power supplies. The modules permit parallel operation for N+1 redundancy with hot swap capability. An embedded DSP provides intelligent start-up and shutdown, output regulation, general control and fault detection. PWM modules in the DSP drive the FET switches at 20 to 100 kHz. The DSP also ensures current sharing between modules, synchronized switching, and soft start up for hot swapping. The module voltage and current have dedicated ADCs (>200 kS/sec) to provide pulse-by-pulse output control. A Dual CAN bus interface provides for low cost redundant control paths. Over-rated module components provide high reliability and high efficiency at full load. Low on-resistance FETs replace conventional diodes in the buck regulator. Saturable inductors limit the FET reverse diode current during switching. The modules operate in a two-quadrant mode, allowing bipolar output from complimentary module groups. Controllable, low resistance FETs at the input and output provide fault isolation and allow module hot swapping.