WorldWideScience

Sample records for high plasma fibrinogen

  1. Plasma Fibrinogen in Patients With Bell Palsy.

    Science.gov (United States)

    Zhao, Hua; Zhang, Xin; Tang, Yinda; Li, Shiting

    2016-10-01

    To determine the plasma fibrinogen level in patients with Bell palsy and explore the significances of it in Bell palsy. One hundred five consecutive patients with facial paralysis were divided into 3 groups: group I (Bell palsy), group II (temporal bone fractures), and group III (facial nerve schwannoma). In addition, 22 volunteers were defined as control group. Two milliliters fasting venous blood from elbow was collected, and was evaluated by CA-7000 Full-Automatic Coagulation Analyzer. The plasma fibrinogen concentration was significantly higher in the group of patients with Bell palsy (HB IV-VI) than that in the control group (P 0.05); similarly, there was also no marked difference between group III and control group (P >0.05). In group I, the plasma fibrinogen levels became higher with the HB grading increase. The plasma fibrinogen level of HB-VI was highest. Plasma fibrinogen has an important clinical meaning in Bell palsy, which should be used as routine examination items. Defibrinogen in treatment for patients with high plasma fibrinogen content also should be suggested.

  2. Clinical and prognostic significance of plasma fibrinogen in lung cancer

    Directory of Open Access Journals (Sweden)

    Chen YS

    2014-01-01

    Full Text Available Objectives: Hyperfibrinogenemia is a common problem associated with various carcinomas. The recent studies have shown that high plasma fibrinogen concentration is associated with invasion, growth and metastases of cancer. Furthermore, the recent studies focus on the prognostic significance of fibrinogen in the patients with advanced NSCLC (stage IIIB -IV. However, the prognostic significance of the plasma fibrinogen levels in early stage NSCLC patients (stage I -IIIA still remains unclear. In addition, it remains unclear whether or not chemotherapy-induced changes in fibrinogen level relate to the prognosis. The aims of this study were to 1 further explore the relationship between the plasma fibrinogen concentration and the stage and metastases of lung cancer 2 evaluate the prognostic significance of the basal plasma fibrinogen level in patients with lung cancer 3 explore the prognostic value of the change in fibrinogen levels between pre and post-chemotherapy. Methods: In this retrospective study, the data from 370 patients with lung cancer were enrolled into this study. The plasma fibrinogen levels were compared with the clinical and prognostic significance of lung cancer. The association between the plasma fibrinogen level and clinical-prognostic characteristics were analyzed using SPSS 17.0 software. Results: 1 The median pre-treatment plasma fibrinogen levels were 4.20g/L. Pre-treatment plasma fibrinogen levels correlated significantly with gender (p = 0.013. A higher plasma fibrinogen concentration was associated with squamous cell carcinoma versus adenocarcinoma (4.83±1.50 g/L versus 4.15±1.30 g/L; P<0.001, there was a significant association between plasma fibrinogen level and metastases of lung cancer, pointing a higher plasma fibrinogen level in lymph nodes or distant organ metastases (p < 0.001. 2 Patients with low plasma fibrinogen concentration demonstrates higher overall survival compared with those with high plasma fibrinogen

  3. Examination of the relation between periodontal health status and cardiovascular risk factors: serum total and high density lipoprotein cholesterol, C-reactive protein, and plasma fibrinogen.

    Science.gov (United States)

    Wu, T; Trevisan, M; Genco, R J; Falkner, K L; Dorn, J P; Sempos, C T

    2000-02-01

    Using data from the Third National Health and Nutrition Examination Survey (1988-1994), the authors examined the relation between periodontal health and cardiovascular risk factors: serum total and high density lipoprotein cholesterol, C-reactive protein, and plasma fibrinogen. A total of 10,146 participants were included in the analyses of cholesterol and C-reactive protein and 4,461 in the analyses of fibrinogen. Periodontal health indicators included the gingival bleeding index, calculus index, and periodontal disease status (defined by pocket depth and attachment loss). While cholesterol and fibrinogen were analyzed as continuous variables, C-reactive protein was dichotomized into two levels. The results show a significant relation between indicators of poor periodontal status and increased C-reactive protein and fibrinogen. The association between periodontal status and total cholesterol level is much weaker. No consistent association between periodontal status and high density lipoprotein cholesterol was detectable. Similar patterns of association were observed for participants aged 17-54 years and those 55 years and older. In conclusion, this study suggests that total cholesterol, C-reactive protein, and fibrinogen are possible intermediate factors that may link periodontal disease to elevated cardiovascular risk.

  4. Fibrinogen estimates are influenced by methods of measurement and hemodilution with colloid plasma expanders.

    Science.gov (United States)

    Fenger-Eriksen, Christian; Moore, Gary W; Rangarajan, Savita; Ingerslev, Jørgen; Sørensen, Benny

    2010-12-01

    Measurement of plasma fibrinogen is often required in critically ill patients or massively bleeding patients being resuscitated with colloid plasma expander. This study aimed at evaluating different assays of plasma fibrinogen after in vitro dilution with commonly used plasma expanders and challenged the hypothesis that levels of fibrinogen are estimated significantly higher in plasma diluted with colloid plasma expander compared with isotonic saline. Fibrinogen measurements were established in plasma samples each diluted in vitro to 30 or 50% with isotonic saline, hydroxyethyl starch (HES) 130/0.4, and human albumin. Fibrinogen levels were assessed using an antigen determination, three photo-optical Clauss methods, one mechanical Clauss method, a prothrombin-derived method, and viscoelastic measurement through thromboelastometry. Measurement of fibrinogen levels was significantly different when performed on alternate analytical platforms. By 30 and 50% dilution with HES 130/0.4 coagulation analyzers using the photo-optical Clauss methods significantly overestimated levels of fibrinogen. Dilution with human albumin did not affect fibrinogen levels except from one analyzer by 50% dilution level. Viscoelastic measurement of fibrin polymerization was reduced at both dilution levels and appeared to reflect the impairment of fibrin polymerization induced by HES 130/0.4 and to a lesser extent human albumin. This study demonstrated that different automated coagulation analyzers revealed significantly different levels of fibrinogen. The presence of colloid plasma expander gave rise to erroneous high levels of fibrinogen returned from some coagulation analyzers employing the method of Clauss. © 2010 American Association of Blood Banks.

  5. Human plasma fibrinogen adsorption and platelet adhesion to polystyrene.

    Science.gov (United States)

    Tsai, W B; Grunkemeier, J M; Horbett, T A

    1999-02-01

    The purpose of this study was to further investigate the role of fibrinogen adsorbed from plasma in mediating platelet adhesion to polymeric biomaterials. Polystyrene was used as a model hydrophobic polymer; i.e., we expected that the role of fibrinogen in platelet adhesion to polystyrene would be representative of other hydrophobic polymers. Platelet adhesion was compared to both the amount and conformation of adsorbed fibrinogen. The strategy was to compare platelet adhesion to surfaces preadsorbed with normal, afibrinogenemic, and fibrinogen-replenished afibrinogenemic plasmas. Platelet adhesion was determined by the lactate dehydrogenase (LDH) method, which was found to be closely correlated with adhesion of 111In-labeled platelets. Fibrinogen adsorption from afibrinogenemic plasma to polystyrene (Immulon I(R)) was low and polystyrene preadsorbed with fibrinogen-replenished afibrinogenemic plasma. Addition of even small, subnormal concentrations of fibrinogen to afibrinogenemic plasma greatly increased platelet adhesion. In addition, surface-bound fibrinogen's ability to mediate platelet adhesion was different, depending on the plasma concentration from which fibrinogen was adsorbed. These differences correlated with changes in the binding of a monoclonal antibody that binds to the Aalpha chain RGDS (572-575), suggesting alteration in the conformation or orientation of the adsorbed fibrinogen. Platelet adhesion to polystyrene preadsorbed with blood plasma thus appears to be a strongly bivariate function of adsorbed fibrinogen, responsive to both low amounts and altered states of the adsorbed molecule. Copyright 1999 John Wiley & Sons, Inc.

  6. Fibrinogen Reduction During Selective Plasma Exchange due to Membrane Fouling.

    Science.gov (United States)

    Ohkubo, Atsushi; Okado, Tomokazu; Miyamoto, Satoko; Hashimoto, Yurie; Komori, Shigeto; Yamamoto, Motoki; Maeda, Takuma; Itagaki, Ayako; Yamamoto, Hiroko; Seshima, Hiroshi; Kurashima, Naoki; Iimori, Soichiro; Naito, Shotaro; Sohara, Eisei; Uchida, Shinichi; Rai, Tatemitsu

    2017-06-01

    Fibrinogen is substantially reduced by most plasmapheresis modalities but retained in selective plasma exchange using Evacure EC-4A10 (EC-4A). Although EC-4A's fibrinogen sieving coefficient is 0, a session of selective plasma exchange reduced fibrinogen by approximately 19%. Here, we investigated sieving coefficient in five patients. When the mean processed plasma volume was 1.15 × plasma volume, the mean reduction of fibrinogen during selective plasma exchange was approximately 15%. Fibrinogen sieving coefficient was 0 when the processed plasma volume was 1.0 L, increasing to 0.07 when the processed plasma volume was 3.0 L, with a mean of 0.03 during selective plasma exchange. When fibrinogen sieving coefficient was 0, selective plasma exchange reduced fibrinogen by approximately 10%. Scanning electron microscopy images revealed internal fouling of EC-4A's hollow fiber membrane by substances such as fibrinogen fibrils. Thus, fibrinogen reduction by selective plasma exchange may be predominantly caused by membrane fouling rather than filtration. © 2017 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  7. Prognostic implications of plasma fibrinogen and serum C- reactive ...

    African Journals Online (AJOL)

    Key words: Plasma fibrinogen, serum C-reactive protein, biomarker, non-small cell lung cancer. Tropical Journal of Pharmaceutical Research ... demonstrated in colorectal [11], cervical, oesophageal [12], and pancreatic cancers .... demographic and clinical characteristic features of the patients involved are shown in Table ...

  8. Prognostic implications of plasma fibrinogen and serum Creactive ...

    African Journals Online (AJOL)

    Purpose: To investigate the prognostic implications of plasma fibrinogen and serum C-reactive protein (CRP) levels in tumour resection and survival following successful tumour resection in patients with nonsmall cell lung cancer (NSCLC). Methods: One hundred and fifty-three NSCLC patients who underwent surgical ...

  9. Prognostic implications of plasma fibrinogen and serum C- reactive ...

    African Journals Online (AJOL)

    reactive protein levels in non-small cell lung cancer resection and ... Abstract. Purpose: To investigate the prognostic implications of plasma fibrinogen and serum C-reactive protein ... The possibility of complete resection and associated findings are reported. Results: ... operable using pre-operative chemotherapy and/or ...

  10. Influence of low- and high-dose radioiodine therapy on oxidative modification of fibrinogen

    International Nuclear Information System (INIS)

    Schweeger-Exeli, I.J.

    2001-10-01

    levels were significantly elevated above 300 mg/dl (p 0.05) and did not change to a significant extent after treatment in both subgroups. Conclusion: Purification of fibrinogen out of small volumes of plasma is feasible in a short period of time and requires only little technical effort. High - dose radioiodine therapy, applied in differentiated thyroid cancer, leads to significantly increased incorporation of carbonyl groups into the fibrinogen molecule. It remains to be elucidated, whether thyroid hormone status itself influences oxidative damage of fibrinogen. Key words: fibrinogen; radioiodine therapy; oxidative modification; isolation techniques; 2,4-dinitrophenylhydrazine. (author)

  11. Plasma circulating fibrinogen stability and moderate beer consumption.

    Science.gov (United States)

    Gorinstein, Shela; Caspi, Abraham; Zemser, Marina; Libman, Imanuel; Goshev, Ivan; Trakhtenberg, Simon

    2003-12-01

    MODERATE BEER CONSUMPTION (MBC) IS CARDIOPROTECTIVE: it positively influences plasma lipid levels and plasma antioxidant activity in beer-consuming individuals. The connection between MBC and blood coagulation is not clearly defined. Forty-two volunteers were equally divided into experimental (EG) and control (CG) groups following coronary bypass surgery. For 30 consecutive days, only patients of the EG consumed 330 mL of beer per day (about 20 g of alcohol). A comprehensive clinical investigation of 42 patients was done. Blood samples were collected before and after the investigation for a wide range of laboratory tests. The plasma fibrinogen was denatured with 8 M urea and intrinsic fluorescence (IF), hydrophobicity and differential scanning calorimetry (DSC) were used to reveal possible qualitative changes. After 30 days of moderate beer consumption, positive changes in the plasma lipid levels, plasma anticoagulant and plasma antioxidant activities were registered in patients of the EG group. In 17 out of 21 patients of the same group, differences in plasma circulating fibrinogen's (PCF), secondary and tertiary structures were found. The stability of fibrinogen, expressed in thermodynamic parameters, has shown that the loosening of the structure takes place under ethanol and urea denaturation. Also fluorescence stability of PCF was decreased. No changes in the lipid levels, anticoagulant and antioxidant activity or changes in PCF were detected in patients of CG. In conclusion, for the first time after a short term of moderate beer consumption some qualitative changes in the plasma circulating fibrinogen were detected: differences in the emission peak response, fluorescence intensity and all thermodynamic data. Together, with the decrease in the PCF concentration it may lead to an elevation of the blood anticoagulant activity.

  12. The preoperative plasma fibrinogen level is an independent prognostic factor for overall survival of breast cancer patients who underwent surgical treatment.

    Science.gov (United States)

    Wen, Jiahuai; Yang, Yanning; Ye, Feng; Huang, Xiaojia; Li, Shuaijie; Wang, Qiong; Xie, Xiaoming

    2015-12-01

    Previous studies have suggested that plasma fibrinogen contributes to tumor cell proliferation, progression and metastasis. The current study was performed to evaluate the prognostic relevance of preoperative plasma fibrinogen in breast cancer patients. Data of 2073 consecutive breast cancer patients, who underwent surgery between January 2002 and December 2008 at the Sun Yat-sen University Cancer Center, were retrospectively evaluated. Plasma fibrinogen levels were routinely measured before surgeries. Participants were grouped by the cutoff value estimated by the receiver operating characteristic (ROC) curve analysis. Overall survival (OS) was assessed using Kaplan-Meier analysis, and multivariate Cox proportional hazards regression model was performed to evaluate the independent prognostic value of plasma fibrinogen level. The optimal cutoff value of preoperative plasma fibrinogen was determined to be 2.83 g/L. The Kaplan-Meier analysis showed that patients with high fibrinogen levels had shorter OS than patients with low fibrinogen levels (p factor for OS in breast cancer patients (HR = 1.475, 95% confidence interval (CI): 1.177-1.848, p = 0.001). Subgroup analyses revealed that plasma fibrinogen level was an unfavorable prognostic parameter in stage II-III, Luminal subtypes and triple-negative breast cancer patients. Elevated preoperative plasma fibrinogen was independently associated with poor prognosis in breast cancer patients and may serve as a valuable parameter for risk assessment in breast cancer patients. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Plasma fibrinogen and factor VII concentrations in adults after prenatal exposure to famine

    NARCIS (Netherlands)

    Roseboom, T. J.; van der Meulen, J. H.; Ravelli, A. C.; Osmond, C.; Barker, D. J.; Bleker, O. P.

    2000-01-01

    To assess the effect of maternal malnutrition during different stages of gestation on plasma concentrations of fibrinogen and factor VII, we investigated 725 people, aged 50 years, born around the time of the Dutch famine 1944-5. After adjustment for sex, plasma fibrinogen concentrations differed by

  14. Modulation of plasma fibrinogen levels by ciprofibrate and gemfibrozil in primary hyperlipidaemia

    NARCIS (Netherlands)

    de Maat, M. P.; Knipscheer, H. C.; Kastelein, J. J.; Kluft, C.

    1997-01-01

    An elevated plasma fibrinogen level is increasingly accepted as an independent risk indicator of cardiovascular disease. This has enhanced the interest in identifying agents that can normalize elevated plasma fibrinogen levels. One group of agents with this capacity are the fibric acid derivatives,

  15. Carotid intima-media thickness and plasma fibrinogen among subjects with metabolic syndrome: Isfahan cohort study

    Directory of Open Access Journals (Sweden)

    Zahra Bayanfar

    2014-09-01

    Full Text Available BACKGROUND: The role of plasma fibrinogen, a key regulator of inflammation processes and increased carotid intima-media thickness (cIMT to predict metabolic syndrome (MetS is currently under investigation. We assessed differences in the indicators of cIMT and also plasma fibrinogen level between MetS and non-MetS subjects. We also assessed the role of these two parameters for independently relationship with MetS state. METHODS: The subjects in this cross-sectional survey were population-based samples of 93 men and women aged ≥ 35 years and over who were selected from the Isfahan cohort study, Isfahan, Iran. Fibrinogen was measured by the clotting assay of Clauss. Ultrasound studies of the carotid artery were performed to measure cIMT. MetS defined based on the National Cholesterol Education Program’s Adult Treatment Panel III. RESULTS: The mean level of plasma fibrinogen was not different in the two groups with and without MetS (240.10 ± 27.80 vs. 242.56 ± 35.82, P = 0.714, but the mean of cIMT was considerably higher in MetS group than in non-MetS group (0.85 ± 0.06 mm vs. 0.66 ± 0.09 mm, P < 0.001. Using a multivariable logistic regression model, high cIMT could effectively predict MetS state with the presence of different components of MetS (odds ratio = 17.544, 95% confidence interval: 2.151-142.860, P = 0.008. The optimal cutoff point of cIMT for discriminating these two clinical states was 0.6 mm yielding a sensitivity of 61.5% and a specificity of 59.6%. CONCLUSION: Individuals with MetS demonstrated increased cIMT values compared with those without MetS. However, high plasma fibrinogen level may not be associated with MetS state.   Keywords: Metabolic Syndrome, Carotid Intima-Media Thickness, Fibrinogen, Prediction 

  16. Elevated plasma fibrinogen associated with reduced pulmonary function and increased risk of chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Dahl, Morten; Tybjaerg-Hansen, A; Vestbo, J

    2001-01-01

    We tested whether increased concentrations of the acute-phase reactant fibrinogen correlate with pulmonary function and rate of chronic obstructive pulmonary disease (COPD) hospitalization. We measured plasma fibrinogen and forced expiratory volume in 1 s (FEV(1)), and assessed prospectively COPD...

  17. BOVINE PLASMA FIBRINOGEN AS MARKER IN CLINICAL AND SUB-CLINICAL MASTITIS

    Directory of Open Access Journals (Sweden)

    R. Ali

    2018-06-01

    Full Text Available Plasma samples were collected from healthy as well as clinical and sub-clinical mastitis affected cows from Barasat, West Bengal, India. Plasma samples, after ammonium sulphate precipitation, were dialyzed against several changes of PBS (pH 7.2 to remove the excess ammonium sulphate. Then plasma fibrinogens were purified by gel filtration chromatography on Sephacryl S-200 HR. SDS-PAGE (10% of purified fibrinogen from plasma of healthy cow revealed polypeptide bands of 74, 67 and 57 kDa which represent the α (alpha, β (beta and γ (gamma- chains respectively. On the other hand, purified fibrinogen from plasma of sub-clinical and clinical mastitis affected cow revealed polypeptide bands of 73 (α-chain, 68 kDa (β-chain and 72 (γ-chain, 68 kDa (β-chain respectively. The SDS-PAGE analysis showed the absence of gamma (γ- chain of fibrinogen in both the samples of sub-clinical and clinical mastitis positive cow. Single precipitin line was observed in double immunodiffusion test when purified fibrinogen from healthy, clinical and subclinical mastitis positive cows reacted with hyper immune sera raised in rabbit. No precipitin line was found against the normal control serum. These purified fibrinogens also showed cross reactivity against antibody raised in rabbit when analyzed by western blot technique.

  18. The effect of 8-week low impact aerobic exercise on plasma fibrinogen concentration in old women

    Directory of Open Access Journals (Sweden)

    Shahla Dehghan

    2013-09-01

    Full Text Available Applied Exercise Physiology focuses on the physiological effects of exercise training on physiological processes, health, and physical well-being. The aim of this study was investigation of effects of 8-week low impact aerobic exercise on plasma fibrinogen concentration in old women. Fibrinogen is one of the most important inflammation factors and a prediction index in cardio vascular diseases. Iranian women especially older ones are generally sedentary because of their traditional and religious believes. Samples were 23 healthy and enable to do physical activity old women of Shahrekord (Chaharmahal va bakhtiary province, Iran retirement home. Subjects were randomly divided to two groups including experimental (n=14 individuals and control (n=11 individuals. First, for assessment of fibrinogen level, 5cc blood samples were obtained after 8 hours nightly fasting from anterior vein in resting condition. Experimental group was participated in 8 week (three times a week LIA training program (15 min in first day with 40% of maximum heart rate until 40 min in last day with 65% of maximum heart rate. All of mentioned measurements repeated at the end of 8 week training. The obtained results showed that 8 week LIA program has significant effect on reduction of old women plasma fibrinogen level (P=0.02. It seems that use of 8 week LIA training has positive effects on improvement of cardiovascular health and prevention of inflammation disease related to plasma fibrinogen level in Iranian old women. Key words: aerobic exercises, old women, fibrinogen.

  19. Beta-fibrinogen allele frequencies in Peruvian Quechua, a high-altitude native population.

    Science.gov (United States)

    Rupert, J L; Devine, D V; Monsalve, M V; Hochachka, P W

    1999-06-01

    Elevated hematocrits, which are found in many high-altitude populations, increase the oxygen-carrying capacity of blood and may represent an adaptation to hypoxic environments. However, as high hematocrit increases blood viscosity, which in turn is associated with hypertension and heart disease, it may be advantageous for high-altitude populations to limit other factors that contribute to increased blood viscosity. One such factor is the plasma concentration of the coagulation protein fibrinogen. Several common polymorphisms in the beta-fibrinogen gene have been identified that affect fibrinogen concentrations. We determined the allele frequencies of three of these polymorphisms (G/A-455(HaeIII), C/T-148(HindIII), and G/A+448(MnlI)) in sample groups drawn from three populations: Quechua-speaking natives living at over 3,200 m in the Peruvian Andes, North American natives (Na-Dene) from coastal British Columbia, and Caucasian North Americans. The frequencies of the alleles previously shown to be associated with increased fibrinogen levels were so low in the Quechuas that their presence could be accounted for solely by genetic admixture with Caucasians. Frequencies in the Na-Dene, a Native American group unrelated to the Quechua, were not significantly different from those in Caucasians.

  20. Fibrinogen plasma concentration is an independent marker of haemodynamic impairment in chronic thromboembolic pulmonary hypertension

    Science.gov (United States)

    Hennigs, Jan K.; Baumann, Hans Jörg; Lüneburg, Nicole; Quast, Gesine; Harbaum, Lars; Heyckendorf, Jan; Sydow, Karsten; Schulte-Hubbert, Bernhard; Halank, Michael; Klose, Hans

    2014-01-01

    Fibrinogen has a crucial role in both inflammation and coagulation, two processes pivotal for the pathogenesis of pulmonary hypertension. We therefore aimed to investigate whether fibrinogen plasma concentrations a) are elevated in pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH) and b) may serve as a novel biomarker for haemodynamic impairment. In a dual-centre, retrospective analysis including 112 patients with PAH (n = 52), CTEPH (n = 49) and a control cohort of patients with suspected PAH ruled out by right heart catheterisation (n = 11), we found fibrinogen plasma concentrations to be increased in patients with PAH (4.1 ± 1.4 g/l) and CTEPH (4.3 ± 1.2 g/l) compared to control patients (3.4 ± 0.5 g/l, p = 0.0035 and p = 0.0004, respectively). In CTEPH patients but not in PAH patients fibrinogen was associated with haemodynamics (p < 0.036) and functional parameters (p < 0.041). Furthermore, fibrinogen was linked to disease severity (WHO functional class, p = 0.017) and independently predicted haemodynamic impairment specifically in CTEPH (p < 0.016). Therefore, fibrinogen seems to represent an important factor in CTEPH pathophysiology and may have the potential to guide clinical diagnosis and therapy. PMID:24770447

  1. External quality assurance of fibrinogen assays using normal plasma: results of the 2008 College of American Pathologists proficiency testing program in coagulation.

    Science.gov (United States)

    Cunningham, Mark T; Olson, John D; Chandler, Wayne L; Van Cott, Elizabeth M; Eby, Charles S; Teruya, Jun; Hollensead, Sandra C; Adcock, Dorothy M; Allison, Paul M; Kottke-Marchant, Kandice K; Smith, Marc D

    2012-07-01

    Proper diagnosis and therapy of fibrinogen deficiency requires high-quality fibrinogen assays. To assess the interlaboratory bias, precision, and grading of fibrinogen assays used by laboratories participating in the United States College of American Pathologists proficiency testing program in coagulation. Two identical vials of normal plasma were sent to more than 3500 laboratories. Participants measured fibrinogen levels using local methods. Fifty different fibrinogen methods were evaluated. All-method bias was 8.3% (range of method-specific biases, 0.0%-27.0%) and all-method coefficient of variation was 7.7% (range of method-specific coefficients of variation, 0.7%-25.8%). After controlling for reagent/instrument type, mean fibrinogen levels were 11.6% higher for prothrombin time-based reagents compared to Clauss (P graded as pass or fail using a target range of ±20% from the method mean (total pass rate, 98.8%). Total fail rate was 3.0-fold lower for mechanical instruments compared to photo-optical (0.5% versus 1.5%, P  =  .001). Nonetheless many photo-optical methods had very high precision and very low fail rates. Fibrinogen assays showed highly variable methodology and performance characteristics. Bias, precision, and grading were affected by the type of reagent or instrument used.

  2. Association between job characteristics and plasma fibrinogen in a normal working population: a cross sectional analysis in referents of the SHEEP Study. Stockholm Heart Epidemiology Program.

    Science.gov (United States)

    Tsutsumi, A; Theorell, T; Hallqvist, J; Reuterwall, C; de Faire, U

    1999-06-01

    To explore the association between job characteristics and plasma fibrinogen concentrations. Cross sectional design. The Greater Stockholm area. A total of 1018 men and 490 women aged 45-70 who were randomly selected from the general population during 1992-1994. They were all employed and had no history of myocardial infarction. The self reported job characteristics were measured by a Swedish version of the Karasek demand-control questionnaire. For inferred scoring of job characteristics, psychosocial exposure categories (job control and psychological demands) were assigned by linking each subject's occupational history with a work organisation exposure matrix. Job strain was defined as the ratio between demands and control. In univariate analyses, expected linear trends were found in three of four tests of association between high plasma fibrinogen and low control (the self reported score for women and the inferred score for both sexes), in one of four tests of association between high plasma fibrinogen and high demands (the inferred score for women) and in two of four tests of association between high plasma fibrinogen and job strain (the inferred score for both sexes). Multiple logistic regression analyses showed that men in the inferred job strain group have an increased risk of falling into the increased plasma fibrinogen concentration group (above median level of the distribution) (odds ratio (OR) 1.2; 95% CI 1.0, 1.5) after adjustment for the variables that were associated with plasma fibrinogen in the univariate analyses. In women, low self reported control, high inferred demand, and inferred job strain were significantly associated with increased plasma fibrinogen concentration (OR 1.3; 95% CI 1.0, 1.8, OR 1.5; 95% CI 1.0, 2.2, OR 1.5; 95% CI 1.1, 2.2, respectively). These results indicate that adverse job characteristics may be related to plasma fibrinogen concentrations and this relation is more relevant in female workers. The clearest evidence for

  3. Elevated plasma fibrinogen, psychological distress, antidepressant use, and hospitalization with depression

    DEFF Research Database (Denmark)

    Wium-Andersen, Marie Kim; Ørsted, David Dynnes; Nordestgaard, Børge Grønne

    2013-01-01

    with depression in the general population. METHODS: We examined 73,367 20-100 year old men and women from two large population-based studies, the Copenhagen General Population Study and the Copenhagen City Heart Study. We measured plasma fibrinogen and recorded symptoms of psychological distress, use......OBJECTIVES: Low-grade systemic inflammation may contribute to the development of depression. We tested the hypothesis that elevated plasma levels of the inflammatory marker fibrinogen are associated with psychological distress, use of antidepressant medication, and with hospitalization...... of antidepressant medication, and hospitalization with depression in both cross-sectional and prospective studies. RESULTS: In cross-sectional analyses, a stepwise increase in fibrinogen percentile categories was associated with a stepwise increase in risk of psychological distress, use of antidepressant medication...

  4. In vitro sealing of iatrogenic fetal membrane defects by a collagen plug imbued with fibrinogen and plasma.

    Science.gov (United States)

    Engels, A C; Hoylaerts, M F; Endo, M; Loyen, S; Verbist, G; Manodoro, S; DeKoninck, P; Richter, J; Deprest, J A

    2013-02-01

    We aimed to demonstrate local thrombin generation by fetal membranes, as well as its ability to generate fibrin from fibrinogen concentrate. Furthermore, we aimed to investigate the efficacy of collagen plugs, soaked with plasma and fibrinogen, to seal iatrogenic fetal membrane defects. Thrombin generation by homogenized fetal membranes was measured by calibrated automated thrombography. To identify the coagulation caused by an iatrogenic membrane defect, we analyzed fibrin formation by optical densitometry, upon various concentrations of fibrinogen. The ability of a collagen plug soaked with fibrinogen and plasma was tested in an ex vivo model for its ability to seal an iatrogenic fetal membrane defect. Fetal membrane homogenates potently induced thrombin generation in amniotic fluid and diluted plasma. Upon the addition of fibrinogen concentrate, potent fibrin formation was triggered. Measured by densiometry, fibrin formation was optimal at 1250 µg/mL fibrinogen in combination with 4% plasma. A collagen plug soaked with fibrinogen and plasma sealed an iatrogenic membrane defect about 35% better than collagen plugs without these additives (P = 0.037). These in vitro experiments suggest that the addition of fibrinogen and plasma may enhance the sealing efficacy of collagen plugs in closing iatrogenic fetal membrane defects. © 2013 John Wiley & Sons, Ltd.

  5. Plasma levels of C-Reactive Protein and Fibrinogen in Pulmonary ...

    African Journals Online (AJOL)

    In this study, we determined the changes in plasma C- reactive protein (C-RP) and Fibrinogen levels in Drug sensitive Tuberculosis (DSTB) patients at diagnosis, Multi drug resistant tuberculosis (MDRTB) patients at diagnosis and during chemotherapy. Twenty-four (24) patients MDRTB patients and 24 newly diagnosed ...

  6. Development of a tool for prediction of ovarian cancer in patients with adnexal masses: Value of plasma fibrinogen.

    Directory of Open Access Journals (Sweden)

    Veronika Seebacher

    Full Text Available To develop a tool for individualized risk estimation of presence of cancer in women with adnexal masses, and to assess the added value of plasma fibrinogen.We performed a retrospective analysis of a prospectively maintained database of 906 patients with adnexal masses who underwent cystectomy or oophorectomy. Uni- and multivariate logistic regression analyses including pre-operative plasma fibrinogen levels and established predictors were performed. A nomogram was generated to predict the probability of ovarian cancer. Internal validation with split-sample analysis was performed. Decision curve analysis (DCA was then used to evaluate the clinical net benefit of the prediction model.Ovarian cancer including borderline tumours was found in 241 (26.6% patients. In multivariate analysis, elevated plasma fibrinogen, elevated CA-125, suspicion for malignancy on ultrasound, and postmenopausal status were associated with ovarian cancer and formed the basis for the nomogram. The overall predictive accuracy of the model, as measured by AUC, was 0.91 (95% CI 0.87-0.94. DCA revealed a net benefit for using this model for predicting ovarian cancer presence compared to a strategy of treat all or treat none.We confirmed the value of plasma fibrinogen as a strong predictor for ovarian cancer in a large cohort of patients with adnexal masses. We developed a highly accurate multivariable model to help in the clinical decision-making regarding the presence of ovarian cancer. This model provided net benefit for a wide range of threshold probabilities. External validation is needed before a recommendation for its use in routine practice can be given.

  7. Relationship between physical activity and plasma fibrinogen concentrations in adults without chronic diseases.

    Directory of Open Access Journals (Sweden)

    Manuel A Gomez-Marcos

    Full Text Available To analyze the relationship between regular physical activity, as assessed by accelerometer and 7-day physical activity recall (PAR, and plasma fibrinogen concentrations.A cross-sectional study in a previously established cohort of healthy subjects was performed. This study analyzed 1284 subjects who were included in the EVIDENT study (mean age 55.0±13.6 years; 60.90% women. Fibrinogen concentrations were measured in blood plasma. Physical activity was assessed with a 7-day PAR (metabolic equivalents (METs/hour/week and GT3X ActiGraph accelerometer (counts/minute for 7 days.Physical exercise, which was evaluated with both an accelerometer (Median: 237.28 counts/minute and 7-day PAR (Median: 8 METs/hour/week. Physical activity was negatively correlated with plasma fibrinogen concentrations, which was evaluated by counts/min (r = -0.100; p<0.001 and METs/hour/week (r = -0.162; p<0.001. In a multiple linear regression analysis, fibrinogen concentrations of the subjects who performed more physical activity (third tertile of count/minute and METs/hour/week respect to subjects who performed less (first tertile, maintained statistical significance after adjustments for age and others confounders (β = -0.03; p = 0.046 and β = -0.06; p<0.001, respectively.Physical activity, as assessed by accelerometer and 7-day PAR, was negatively associated with plasma fibrinogen concentrations. This relation is maintained in subjects who performed more exercise even after adjusting for age and other confounders.

  8. Plasma fibrinogen in relation to serum insulin, smoking habits and adipose tissue fatty acids in healthy men

    NARCIS (Netherlands)

    Cigolini, M; Targher, G; de Sandre, G; Muggeo, M; Seidell, J C

    Recent prospective studies have reported an independent association between fibrinogen plasma levels and risk of cardiovascular events. Aim of this study was to investigate the relationships between fibrinogen level and conventional cardiovascular risk factors in a random sample of 38 year-old

  9. Evaluation of plasma fibrinogen concentration as a diagnostic indicator of inflammation in red-eared sliders (Trachemys scripta elegans).

    Science.gov (United States)

    Moore, A Russell; Allender, Matthew C; Mitchell, Mark A; MacNeill, Amy L

    2015-01-15

    To critically evaluate plasma fibrinogen concentration as a diagnostic indicator of inflammation in red-eared sliders (Trachemys scripta elegans). Prospective induced-disease model and prospective cross-sectional study. Plasma samples from 12 purpose-bred red-eared sliders and 153 farm-raised red-eared sliders. A modification of the Jacobsson method was developed to measure fibrinogen concentration in platelet-poor plasma from red-eared sliders. Purpose-bred turtles had been inoculated with a ranavirus (n = 4) or sterile PBS solution (8) as part of another study. Farm-raised red-eared sliders were categorized as healthy (n = 138) or overtly ill (15) on the basis of physical examination findings at the time of blood sample collection. Samples from 124 of the 138 healthy red-eared sliders were used to establish a fibrinogen concentration reference interval as measured by the modified Jacobsson method. Fibrinogen concentrations in ranavirus-infected and physically ill turtles were compared with those of healthy turtles to determine whether fibrinogen concentration would be a useful diagnostic indicator of inflammation in red-eared sliders. The modified Jacobsson method was reliably used to measure fibrinogen concentration. The fibrinogen concentration reference interval from healthy reproductively active female red-eared sliders was right skewed. Fibrinogen concentration did not differ significantly between healthy red-eared sliders and ranavirus-infected or overtly ill red-eared sliders. A reference interval for red-eared slider plasma fibrinogen concentration was established and partitioned by sex to account for considerable right skewing observed for females. Fibrinogen concentration was not a useful indicator of inflammation in red-eared sliders with ranavirus infection or other overt illnesses.

  10. Fibrinogen measurements in plasma and whole blood: a performance evaluation study of the dry-hematology system.

    Science.gov (United States)

    Ogawa, Satoru; Tanaka, Kenichi A; Nakajima, Yasufumi; Nakayama, Yoshinobu; Takeshita, Jun; Arai, Masatoshi; Mizobe, Toshiki

    2015-01-01

    An accurate and rapid determination of fibrinogen level is important during hemorrhage to establish a timely hemostatic intervention. The accuracy of fibrinogen measurements may be affected by the specific methodology for its determination, fluid therapies, and anticoagulant agents. The dry-hematology method (DRIHEMATO®) is a novel approach to determine fibrinogen levels in plasma and whole blood based on thrombin-activated coagulation time. We hypothesized that plasma or whole blood fibrinogen level using the dry-hematology method would be similar to those measured with conventional plasma fibrinogen assays. Acquired hypofibrinogenemia was modeled by serial dilutions of blood samples obtained from 12 healthy volunteers. Citrated whole blood samples were diluted with either normal saline, 5% human albumin, or 6% hydroxyethyl starch to achieve 25%, 50%, and 75% volume replacement. The dry-hematology method, the Clauss method, the prothrombin time (PT)-derived method, determination of antigen levels, and thromboelastometric fibrin formation were compared in plasma or whole blood samples. The effect of heparin on each assay was examined (0 to 6 IU/mL). Comparisons of dry-hematology and other methods were also conducted using ex vivo samples obtained from cardiac surgical patients (n = 60). In plasma samples, there were no significant differences between dry-hematology and the Clauss method, while dry-hematology showed lower fibrinogen levels compared with PT-derived and antigen level methods. The dry-hematology method yielded acceptable concordance correlation coefficients (Pc) with the Clauss method, the PT-derived method, and fibrinogen antigen levels (Pc = 0.91-0.99). The type of diluents and heparin affected the results of the PT-derived method and thromboelastometric assay, but not the dry-hematology method. In cardiac surgical patients, the overall correlation in fibrinogen levels between dry-hematology and the other methods was comparable to the results from

  11. Beta fibrinogen gene polymorphisms are associated with plasma fibrinogen and coronary artery disease in patients with myocardial infarction. The ECTIM Study. Etude Cas-Temoins sur l'Infarctus du Myocarde.

    Science.gov (United States)

    Behague, I; Poirier, O; Nicaud, V; Evans, A; Arveiler, D; Luc, G; Cambou, J P; Scarabin, P Y; Bara, L; Green, F; Cambien, F

    1996-02-01

    Polymorphisms of the beta fibrinogen gene have been shown to affect plasma fibrinogen levels and the risk of peripheral arterial disease. We now present the results of a detailed analysis of the beta fibrinogen gene in relation to plasma fibrinogen and to the severity of coronary artery disease (CAD) in patients with myocardial infarction (MI) in the ECTIM Study. Ten polymorphisms of the beta fibrinogen gene, including five new polymorphisms identified by single-strand conformation polymorphism analysis, and one polymorphism in the 3' flanking region of the alpha fibrinogen gene were investigated in 565 patients with MI and 668 control subjects. The polymorphisms were in tight linkage disequilibrium and the genotype frequencies were similar in patients with MI and control subjects. In the multivariate analysis, only two polymorphisms, beta Hae III (P 50% stenosis was estimated by angiography and used as a criterion for severity of CAD. Presence of the less frequent allele of the beta Bcl I (P < .0003) and of other polymorphisms was positively associated with the severity of CAD. Genetic variants of the beta fibrinogen gene are associated with an increased plasma level of fibrinogen, especially in smokers. The association with CAD appears to be the consequence of an increased risk of MI in subjects with severe CAD who carry the predisposing beta fibrinogen genotypes.

  12. Prognostic significance of pretreatment plasma fibrinogen level in patients with digestive system tumors: a meta-analysis.

    Science.gov (United States)

    Ji, Rui; Ren, Qian; Bai, Suyang; Wang, Yuping; Zhou, Yongning

    2018-06-01

    High pretreatment levels of plasma fibrinogen have been widely reported to be a potential predictor of prognosis in digestive system tumors; however, the conclusions are not consistent. Therefore, we performed a meta-analysis to comprehensively assess the prognostic roles of high pretreatment plasma fibrinogen levels in digestive system tumors. We searched for eligible studies in the PubMed, Embase, and Web of Science electronic databases for publications from the database inception to 1 September 2017. The endpoints of interest included overall survival, disease-free survival, and recurrence-free survival. We investigated the relationship between fibrinogenemia and overall survival in colorectal cancer (10 studies), gastric cancer (6), pancreatic cancer (6), hepatocellular carcinoma (7), and esophageal squamous cell carcinoma (10); the pooled results indicated that fibrinogenemia was significantly related to a worse overall survival (hazard ratio (HR) 1.73; 95% confidence interval (CI) 1.52, 1.97; P digestive system tumors, indicating that it could be a useful prognostic marker in these types of tumors.

  13. Effect of Metformin on Plasma Fibrinogen Concentrations: A Systematic Review and Meta-Analysis of Randomized Placebo-Controlled Trials.

    Science.gov (United States)

    Simental-Mendia, Luis E; Pirro, Matteo; Atkin, Stephen L; Banach, Maciej; Mikhailidis, Dimitri P; Sahebkar, Amirhossein

    2018-01-01

    Fibrinogen is a key mediator of thrombosis and it has been implicated in the pathogenesis of atherosclerosis. Because metformin has shown a potential protective effect on different atherothrombotic risk factors, we assessed in this meta-analysis its effect on plasma fibrinogen concentrations. A systematic review and meta-analysis was carried out to identify randomized placebo-controlled trials evaluating the effect of metformin administration on fibrinogen levels. The search included PubMed-Medline, Scopus, ISI Web of Knowledge and Google Scholar databases (by June 2, 2017) and quality of studies was performed according to Cochrane criteria. Quantitative data synthesis was conducted using a random-effects model and sensitivity analysis by the leave-one-out method. Meta-regression analysis was performed to assess the modifiers of treatment response. Meta-analysis of data from 9 randomized placebo-controlled clinical trials with 2302 patients comprising 10 treatment arms did not suggest a significant change in plasma fibrinogen concentrations following metformin therapy (WMD: -0.25 g/L, 95% CI: -0.53, 0.04, p = 0.092). The effect size was robust in the leave-one-out sensitivity analysis and remained non-significant after omission of each single study from the meta-analysis. No significant effect of metformin on plasma fibrinogen concentrations was demonstrated in the current meta-analysis. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  14. Effects of kiwi consumption on plasma lipids, fibrinogen and insulin resistance in the context of a normal diet.

    Science.gov (United States)

    Recio-Rodriguez, Jose I; Gomez-Marcos, Manuel A; Patino-Alonso, Maria C; Puigdomenech, Elisa; Notario-Pacheco, Blanca; Mendizabal-Gallastegui, Nere; de la Fuente, Aventina de la Cal; Otegui-Ilarduya, Luis; Maderuelo-Fernandez, Jose A; de Cabo Laso, Angela; Agudo-Conde, Cristina; Garcia-Ortiz, Luis

    2015-09-15

    Among fruits, kiwi is one of the richest in vitamins and polyphenols and has strong anti-oxidant effects. We aimed to analyze the relationship between the consumption of kiwi and plasma lipid values, fibrinogen, and insulin resistance in adults within the context of a normal diet and physical-activity. Cross-sectional study. Participants (N = 1469), who were free of cardiovascular diseases, completed a visit, which included the collection of information concerning the participant's usual diet and kiwi consumption using a previously validated, semi-quantitative, 137-item food-frequency-questionnaire. Fasting laboratory determinations included plasma lipids, fibrinogen and insulin resistance. Regular physical-activity was determined using accelerometry. Consumers of at least 1 kiwi/week presented higher plasma values of HDL-cholesterol (mean difference 4.50 [95% CI: 2.63 to 6.36]) and lower triglyceride values (mean difference -20.03 [95% CI: -6.77 to -33.29]), fibrinogen values (mean difference -13.22 [95% CI: -2.18 to -24.26]) and HOMAir values (mean difference -0.30 [95% CI: -0.09 to -0.50]) (p Consumption of at least one kiwi/week is associated with lower plasma concentrations of fibrinogen and improved plasma lipid profile in the context of a normal diet and regular exercise.

  15. Nattokinase decreases plasma levels of fibrinogen, factor VII, and factor VIII in human subjects.

    Science.gov (United States)

    Hsia, Chien-Hsun; Shen, Ming-Ching; Lin, Jen-Shiou; Wen, Yao-Ke; Hwang, Kai-Lin; Cham, Thau-Ming; Yang, Nae-Cherng

    2009-03-01

    Nattokinase, a serine proteinase from Bacillus subtilis, is considered to be one of the most active functional ingredients found in natto. In this study, we hypothesized that nattokinase could reduce certain factors of blood clotting and lipids that are associated with an increase risk for cardiovascular disease (CVD). Thus, an open-label, self-controlled clinical trial was conducted on subjects of the following groups: healthy volunteers (Healthy Group), patients with cardiovascular risk factors (Cardiovascular Group), and patients undergoing dialysis (Dialysis Group). All subjects ingested 2 capsules of nattokinase (2000 fibrinolysis units per capsule) daily orally for 2 months. The laboratory measurements were performed on the screening visit and, subsequently, regularly after the initiation of the study. The intent-to-treat analysis was performed on all 45 enrolled subjects. By use of mixed model analysis, a significant time effect, but not group effect, was observed in the change from baseline of fibrinogen (P = .003), factor VII (P nattokinase. No significant changes of uric acid or notable adverse events were observed in any of the subjects. In summary, this study showed that oral administration of nattokinase could be considered as a CVD nutraceutical by decreasing plasma levels of fibrinogen, factor VII, and factor VIII.

  16. Fibrinogen and ceruloplasmin in plasma and milk from dairy cows with subclinical and clinical mastitis.

    Science.gov (United States)

    Tabrizi, A Davasaz; Batavani, R A; Rezaei, S Asri; Ahmadi, M

    2008-02-15

    The potential using of Acute Phase Proteins (APPs) in the assessment of mammary gland health was studied by examining the levels of Fibrinogen (Fb) and Ceruloplasmin (Cp) in plasma and milk from dairy cows with different grades of mastitis. Plasma samples were taken from jugular vein and milk samples were collected from quarters of cows with subclinical and clinical mastitis, as well as healthy controls. California Mastitis Test (CMT) were performed on each udder quarter of cows for detection of CMT2+ and CMT3+ quarters. CMT (0) and culture negative cases were considered healthy cows. Clinical mastitis, was graded as mild (clots in milk) or moderate (clots in milk and visible signs of inflammation in the mammary gland/s). The concentrations of Fb in the plasma of the cows with subclinical and clinical mastitis were higher than in the plasma of the healthy cows (p0.05), but differences between clinical and healthy groups were significant (pmastitis were higher than in the milk of the healthy cows (pmastitis in dairy cows.

  17. Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses

    Directory of Open Access Journals (Sweden)

    Eliseo Portilla-de Buen

    2014-04-01

    Full Text Available OBJECTIVE: Fibrin glues have not been consistently successful in preventing the dehiscence of high-risk colonic anastomoses. Fibrinogen and thrombin concentrations in glues determine their ability to function as sealants, healers, and/or adhesives. The objective of the current study was to compare the effects of different concentrations of fibrinogen and thrombin on bursting pressure, leaks, dehiscence, and morphology of high-risk ischemic colonic anastomoses using fibrin glue in rats. METHODS: Colonic anastomoses in adult female Sprague-Dawley rats (weight, 250-350 g treated with fibrin glue containing different concentrations of fibrinogen and thrombin were evaluated at post-operative day 5. The interventions were low-risk (normal or high-risk (ischemic end-to-end colonic anastomoses using polypropylene sutures and topical application of fibrinogen at high (120 mg/mL or low (40 mg/mL concentrations and thrombin at high (1000 IU/mL or low (500 IU/mL concentrations. RESULTS: Ischemia alone, anastomosis alone, or both together reduced the bursting pressure. Glues containing a low fibrinogen concentration improved this parameter in all cases. High thrombin in combination with low fibrinogen also improved adherence exclusively in low-risk anastomoses. No differences were detected with respect to macroscopic parameters, histopathology, or hydroxyproline content at 5 days post-anastomosis. CONCLUSIONS: Fibrin glue with a low fibrinogen content normalizes the bursting pressure of high-risk ischemic left-colon anastomoses in rats at day 5 after surgery.

  18. Increasing plasma fibrinogen, but unchanged levels of intraplatelet cyclic nucleotides, plasma endothelin-1, factor VII, and neopterin during cholesterol lowering with fluvastatin.

    Science.gov (United States)

    Gottsäter, A; Anwaar, I; Lind, P; Mattiasson, I; Lindgärde, F

    1999-04-01

    Lipid-lowering statin treatment reduces cardiovascular morbidity and mortality and improves endothelial function in patients with hypercholesterolemia. The aim of the present study was to evaluate plasma levels of fibrinogen, factor VII, and the macrophage-derived inflammatory mediator neopterin during lipid lowering. In addition, the endothelial production of platelet antiaggregatory and vasodilatory factors such as nitric oxide and prostacyclin, and vasoconstrictive factors such as endothelin-1, was assessed. Plasma fibrinogen, factor VII, endothelin-1, and the neopterin and intraplatelet nitric oxide and prostacyclin mediators cyclic 3'-5'guanosine monophosphate (cGMP) and cyclic 3'-5'adenosine monophosphate (cAMP) were measured before and 6 months after the institution of treatment with fluvastatin in 17 patients (eight men and nine women, median age 60 years) with vascular disease and previously untreated hypercholesterolemia. After 6 months, a decrease of 1.62 mmol/l [1.26-2.18 (19%); P factor VII [from 1.14 IE/ml (0.58-1.38) to 1.22 IE/ml (0.96-1.46); NS], or plasma neopterin [from 8.6 nmol/l (7.1-11.5) to 8.7 nmol/l (7.9-11.3); NS]. In conclusion, during cholesterol-lowering treatment with fluvastatin, plasma levels of fibrinogen increased whereas intraplatelet cyclic nucleotide levels and plasma endothelin-1, factor VII and neopterin levels were unchanged.

  19. The acute effect of cigarette smoking on the high-sensitivity CRP and fibrinogen biomarkers in chronic obstructive pulmonary disease patients.

    Science.gov (United States)

    van Dijk, Wouter D; Akkermans, Reinier; Heijdra, Yvonne; Weel, Chris van; Schermer, Tjard R J; Scheepers, Paul T J; Lenders, Jacques W M

    2013-04-01

    The evidence on the acute effects of smoking on biomarkers is limited. Our aim was to study the acute effect of smoking on disease-related biomarkers. The acute effect of smoking on serum high sensitivity CRP (hs-CRP) and plasma fibrinogen and its association with disease severity was studied by challenging 31 chronic obstructive pulmonary disease patients with cigarette smoking and repeatedly measuring these biomarkers before and after smoking. Fibrinogen and hs-CRP increased directly after smoking by 9.4 mg/dl (95% CI: 4.2-14.5) and 0.13 mg/l (95% CI: 0.03-0.23), respectively. Fibrinogen levels remained elevated after 35 min, whereas hs-CRP normalized. Pearson's correlation coefficient between the hs-CRP change and chronic obstructive pulmonary disease severity was 0.25 (p = 0.06). Fibrinogen and hs-CRP increased directly after smoking in the chronic obstructive pulmonary disease patients. Their association with disease risk and/or progression remains to be demonstrated.

  20. Circulating immune complexes contain citrullinated fibrinogen in rheumatoid arthritis

    Science.gov (United States)

    Zhao, Xiaoyan; Okeke, Nwora Lance; Sharpe, Orr; Batliwalla, Franak M; Lee, Annette T; Ho, Peggy P; Tomooka, Beren H; Gregersen, Peter K; Robinson, William H

    2008-01-01

    Introduction There is increasing evidence that autoantibodies and immune complexes (ICs) contribute to synovitis in rheumatoid arthritis (RA), yet the autoantigens incorporated in ICs in RA remain incompletely characterised. Methods We used the C1q protein to capture ICs from plasma derived from human RA and control patients. Antibodies specific for immunoglobulin were used to detect ICs, and fibrinogen antibodies were used to detect fibrinogen-containing ICs. RA and control plasma were separated by liquid chromatography, and fractions then characterised by ELISA, immunoblotting and mass spectrometry. Immunohistochemical staining was performed on rheumatoid synovial tissue. Results C1q-immunoassays demonstrated increased levels of IgG (p = 0.01) and IgM (p = 0.0002) ICs in plasma derived from RA patients possessing anti-cyclic citrullinated peptide (CCP+) autoantibodies as compared with healthy controls. About one-half of the anti-CCP+ RA possessed circulating ICs containing fibrinogen (p = 0.0004). Fractionation of whole RA plasma revealed citrullinated fibrinogen in the high molecular weight fractions that contained ICs. Positive correlations were observed between fibrinogen-containing ICs and anti-citrullinated fibrinogen autoantibodies, anti-CCP antibody, rheumatoid factor and certain clinical characteristics. Immunohistochemical staining demonstrated co-localisation of fibrinogen, immunoglobulin and complement component C3 in RA pannus tissue. Mass spectrometry analysis of immune complexes immunoprecipitated from RA pannus tissue lysates demonstrated the presence of citrullinated fibrinogen. Conclusion Circulating ICs containing citrullinated fibrinogen are present in one-half of anti-CCP+ RA patients, and these ICs co-localise with C3 in the rheumatoid synovium suggesting that they contribute to synovitis in a subset of RA patients. PMID:18710572

  1. Relative effects of plasma, fibrinogen concentrate, and factor XIII on ROTEM coagulation profiles in an in vitro model of massive transfusion in trauma.

    Science.gov (United States)

    Schmidt, David E; Halmin, Märit; Wikman, Agneta; Östlund, Anders; Ågren, Anna

    2017-10-01

    Massive traumatic haemorrhage is aggravated through the development of trauma-induced coagulopathy, which is managed by plasma transfusion and/or fibrinogen concentrate administration. It is yet unclear whether these treatments are equally potent in ensuring adequate haemostasis, and whether additional factor XIII (FXIII) administration provides further benefits. In this study, we compared ROTEM whole blood coagulation profiles after experimental massive transfusion with different transfusion regimens in an in vitro model of dilution- and transfusion-related coagulopathy. Healthy donor blood was mixed 1 + 1 with six different transfusion regimens. Each regimen contained RBC, platelet concentrate, and either fresh frozen plasma (FFP) or Ringer's acetate (RA). The regimens were further augmented through addition of a low- or medium-dose fibrinogen concentrate and FXIII. Transfusion with FFP alone was insufficient to maintain tissue-factor activated clot strength, coincidental with a deficiency in fibrin-based clot strength. Fibrinogen concentrate conserved, but did not improve coagulation kinetics and overall clot strength. Only combination therapy with FFP and low-dose fibrinogen concentrate improved both coagulation kinetics and fibrin-based clot strength. Administration of FXIII did not result in an improvement of clot strength. In conclusion, combination therapy with both FFP and low-dose fibrinogen concentrate improved clotting time and produced firm clots, representing a possible preferred first-line regimen to manage trauma-induced coagulopathy when RBC and platelets are also transfused. Further research is required to identify optimal first-line transfusion fluids for massive traumatic haemorrhage.

  2. No evidence for genome-wide interactions on plasma fibrinogen by smoking, alcohol consumption and body mass index: results from meta-analyses of 80,607 subjects.

    Directory of Open Access Journals (Sweden)

    Jens Baumert

    Full Text Available Plasma fibrinogen is an acute phase protein playing an important role in the blood coagulation cascade having strong associations with smoking, alcohol consumption and body mass index (BMI. Genome-wide association studies (GWAS have identified a variety of gene regions associated with elevated plasma fibrinogen concentrations. However, little is yet known about how associations between environmental factors and fibrinogen might be modified by genetic variation. Therefore, we conducted large-scale meta-analyses of genome-wide interaction studies to identify possible interactions of genetic variants and smoking status, alcohol consumption or BMI on fibrinogen concentration. The present study included 80,607 subjects of European ancestry from 22 studies. Genome-wide interaction analyses were performed separately in each study for about 2.6 million single nucleotide polymorphisms (SNPs across the 22 autosomal chromosomes. For each SNP and risk factor, we performed a linear regression under an additive genetic model including an interaction term between SNP and risk factor. Interaction estimates were meta-analysed using a fixed-effects model. No genome-wide significant interaction with smoking status, alcohol consumption or BMI was observed in the meta-analyses. The most suggestive interaction was found for smoking and rs10519203, located in the LOC123688 region on chromosome 15, with a p value of 6.2 × 10(-8. This large genome-wide interaction study including 80,607 participants found no strong evidence of interaction between genetic variants and smoking status, alcohol consumption or BMI on fibrinogen concentrations. Further studies are needed to yield deeper insight in the interplay between environmental factors and gene variants on the regulation of fibrinogen concentrations.

  3. Periodontal therapy reduces plasma levels of interleukin-6, C-reactive protein, and fibrinogen in patients with severe periodontitis and refractory arterial hypertension.

    Science.gov (United States)

    Vidal, Fábio; Figueredo, Carlos Marcelo S; Cordovil, Ivan; Fischer, Ricardo G

    2009-05-01

    Recent epidemiologic studies suggest that inflammation is the link between periodontal diseases and cardiovascular complications. This study aimed to evaluate the effects of non-surgical periodontal treatment on plasma levels of inflammatory markers (interleukin [IL]-6, C-reactive protein [CRP], and fibrinogen) in patients with severe periodontitis and refractory arterial hypertension. Twenty-two patients were examined and randomly divided into two groups. The test group was composed of 11 patients (mean age, 48.9 +/- 3.9 years) who received periodontal treatment, whereas the control group had 11 patients (mean age, 49.7 +/- 6.0 years) whose treatment was delayed for 3 months. Demographic and clinical periodontal data were collected, and blood tests were performed to measure the levels of IL-6, CRP, and fibrinogen at baseline and 3 months later. The clinical results showed that the mean percentages of sites with bleeding on probing, probing depth (PD) 4 to 5 mm, PD > or =6 mm, clinical attachment loss (CAL) 4 to 5 mm, and CAL > or =6 mm were significantly reduced in the test group 3 months after periodontal treatment. There were no significant differences between the data at baseline and 3 months in the control group. Periodontal treatment significantly reduced the blood levels of fibrinogen, CRP, and IL-6 in the test group. Non-surgical periodontal therapy was effective in improving periodontal clinical data and in reducing the plasma levels of IL-6, CRP, and fibrinogen in hypertensive patients with severe periodontitis.

  4. Plasma levels of C-Reactive Protein and Fibrinogen in Pulmonary ...

    African Journals Online (AJOL)

    Dr Olaleye

    heparin tubes before the commencement of chemotherapy, 2 months, 4 months and 6 months of anti-TB therapy. Plasma obtained ... resistant tuberculosis were significantly reduced during chemotherapy compared with before commencement of chemotherapy. Plasma CRP and ... This type of response involves the ...

  5. Ex vivo addition of fibrinogen concentrate improves the fibrin network structure in plasma samples taken during liver transplantation

    NARCIS (Netherlands)

    Groeneveld, D. J.; Adelmeijer, J.; Hugenholtz, G. C. G.; Ariens, R. A. S.; Porte, R. J.; Lisman, T.

    2015-01-01

    Background: Optimal hemostatic management during orthotopic liver transplantation (OLT) remains a challenge. The cause of bleeding during OLT is multifactorial, and may include hemostatic imbalance. Fibrinogen concentrates are increasingly being used to control perioperative bleeding during OLT.

  6. Fibrinogen monitor

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus is described for use in detecting the formation of blood clots in a patient who has previously been injected with a tracer quantity of radioactive fibrinogen. It consists of a scintillation detector, associated electronics for pulse processing and a digital display for the operator as well as a punched paper-tape for permanent record. The detector measures the radioactive count rate along the patient's leg over a given interval and compares this with a reference value. Higher count rate events which are deemed to be statistically significant, indicate thrombosis. Lower than average count rates usually indicate mis-alignment of the detector and patient's leg and warning of such is given to the operator. Compared to previous instruments, the present apparatus is easier to use and is also more comfortable for the patient. (UK)

  7. Anticoagulant and calcium-binding properties of high molecular weight derivatives of human fibrinogen (plasmin fragments Y)

    NARCIS (Netherlands)

    Nieuwenhuizen, W.; Voskuilen, M.; Hermans, J.

    1982-01-01

    The present study was undertaken as a step to delineate further the localization of the calcium-binding sites in fibrinogen and to assess the anticlotting properties of fibrinogen degradation products. To this purpose, fragments Y were prepared by plasmin digestion of human fibrinogen in the

  8. Moderate alcohol consumption reduces plasma C-reactive protein and fibrinogen levels : a randomized, diet-controlled intervention study

    NARCIS (Netherlands)

    Sierksma, A.; Gaag, M.S. van der; Kluft, C.; Hendriks, H.F.J.

    2002-01-01

    Objective: To evaluate the effect of moderate alcohol consumption on the acute phase proteins C-reactive protein and fibrinogen. Design: Randomized, diet-controlled, cross-over study. Setting: The study was performed at TNO Nutrition and Food Research, Zeist, The Netherlands. Subjects: Ten

  9. Circulating fibrinogen but not D-dimer level is associated with vital exhaustion in school teachers.

    Science.gov (United States)

    Kudielka, Brigitte M; Bellingrath, Silja; von Känel, Roland

    2008-07-01

    Meta-analyses have established elevated fibrinogen and D-dimer levels in the circulation as biological risk factors for the development and progression of coronary artery disease (CAD). Here, we investigated whether vital exhaustion (VE), a known psychosocial risk factor for CAD, is associated with fibrinogen and D-dimer levels in a sample of apparently healthy school teachers. The teaching profession has been proposed as a potentially high stressful occupation due to enhanced psychosocial stress at the workplace. Plasma fibrinogen and D-dimer levels were measured in 150 middle-aged male and female teachers derived from the first year of the Trier-Teacher-Stress-Study. Log-transformed levels were analyzed using linear regression. Results yielded a significant association between VE and fibrinogen (p = 0.02) but not D-dimer controlling for relevant covariates. Further investigation of possible interaction effects resulted in a significant association between fibrinogen and the interaction term "VE x gender" (p = 0.05). In a secondary analysis, we reran linear regression models for males and females separately. Gender-specific results revealed that the association between fibrinogen and VE remained significant in males but not females. In sum, the present data support the notion that fibrinogen levels are positively related to VE. Elevated fibrinogen might be one biological pathway by which chronic work stress may impact on teachers' cardiovascular health in the long run.

  10. Association of Fibrinogen with Severity of Stable Coronary Artery Disease in Patients with Type 2 Diabetic Mellitus

    Directory of Open Access Journals (Sweden)

    Li-Feng Hong

    2014-01-01

    Full Text Available Background. Some studies have suggested a relation of plasma fibrinogen to the severity of coronary artery disease (CAD. However, whether plasma fibrinogen can predict the presence and severity of CAD in patients with diabetes mellitus has not been determined. Methods. A total of consecutive 373 diabetic patients with typical angina pectoris who received coronary angiography were enrolled and classified into three groups by tertiles of Gensini score (GS, low group 28. The relationship between fibrinogen and GS was evaluated. Results. There were correlations of fibrinogen with hemoglobin A1c, C-reactive protein, and GS (r=0.17, r=0.52, and r=0.21, resp.; all P<0.001. Area under the receivers operating characteristic curve of fibrinogen was 0.62 (95% CI 0.56–0.68, P<0.001 for predicting a high GS. Multivariate analysis suggested that plasma fibrinogen was an independent predictor of a high GS for diabetic patients (OR=1.40, 95% CI 1.04–1.88, and P=0.026 after adjusting for traditional risk factors of CAD. Conclusions. The present data indicated that plasma fibrinogen, a readily measurable systematic inflammatory marker, appeared to be an independent predictor for the severity of CAD in diabetic patients.

  11. Early fibrinogen degradation coagulopathy: a predictive factor of parenchymal hematomas in cerebral rt-PA thrombolysis.

    Science.gov (United States)

    Sun, Xuhong; Berthiller, Julien; Trouillas, Paul; Derex, Laurent; Diallo, Laho; Hanss, Michel

    2015-04-15

    The purpose of this study was to systematically determine the correlations between the post-thrombolytic changes of hemostasis parameters and the occurrence of early intracerebral hemorrhage (ICH). In 72 consecutive patients with cerebral infarcts treated with rt-PA, plasma levels of fibrinogen, plasminogen, alpha2-antiplasmin, factor XIII, fibrin(ogen) degradation products (FDPs) and d-Dimers were measured at baseline, 2 and 24h after thrombolysis. Correlations were studied between the hemostasis events and early (less than 24h) hemorrhagic infarcts (HIs) or parenchymatous hematomas (PH). Of 72 patients, 6 patients (8.3%) had early PHs, 11 (15.3%) had early HIs, and 55 (76.4%) had no bleeding. Early HIs were not linked to any hemostasis parameter at any time. Univariate comparison of patients having early PHs with non-bleeding patients showed hemostasis abnormalities at 2h: high FDP (p=0.01), high Log FDP (p=0.01), low fibrinogen (p=0.01), and low Log fibrinogen (p=0.01). Logistic regression adjusted for age, NIHSS and diabetes confirmed these 2hour predictors: Log FDP (OR: 7.50; CI: 1.26 to 44.61, p=0.03), and Log fibrinogen (OR: 19.32; CI: 1.81 to 205.98, p=0.01). The decrease in fibrinogen less than 2g/L multiplies the odds of early PH by a factor 12.82. An early fibrinogen degradation coagulopathy involving an increase of FDP and a massive consumption of circulating fibrinogen is predictive of early parenchymal hematomas, indicating the occurrence of a particularly intense lysis of circulating fibrinogen. These results, if confirmed by future studies, suggest that early assays of fibrinogen and FDP may be useful in predicting the risk of post-thrombolytic intracerebral hematoma. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Study of radioactive fibrinogen metabolism in renal allotransplantation

    International Nuclear Information System (INIS)

    Akiyama, Takahiro; Nagai, Nobuo; Kaneko, Shigeo; Matsuura, Takeshi; Iguchi, Masanori

    1979-01-01

    Turn over administrated radioactive fibrinogen and uptake to renal allograft were studied in 9 cases of renal allotransplanted patients. In patients with acute rejection crisis biological half-time (T 1/2) of 131 I-fibrinogen were shortened and allograft/heart counts ratio of 125 I-fibrinogen were elevated up to 125 - 140 percent at 24 - 48 hours after administration; these parameters seemed to be useful in aid of diagnosis of acute rejection. It is suggested that deposition of fibrinogen into allograft and increased turn over of plasma fibrinogen occurred in acute rejection. (author)

  13. A novel fibrin gel derived from hyaluronic acid-grafted fibrinogen

    International Nuclear Information System (INIS)

    Yang, Chiung L; Chen, Hui W; Wang, Tzu C; Wang, Yng J

    2011-01-01

    Fibrinogen is a major plasma protein that forms a three-dimensional fibrin gel upon being activated by thrombin. In this study, we report the synthesis and potential applications of hybrid molecules composed of fibrinogen coupled to the reducing ends of short-chain hyaluronic acids (sHAs) by reductive amination. The grafting of sHAs to fibrinogen was verified by analyzing particle size, zeta potential and gel-electrophoretic mobility of the hybrid molecules. The sHA-fibrinogen hybrid molecules with graft ratios (sHA/fibrinogen) of up to 6.5 retained the ability to form gels in response to thrombin activation. The sHA-fibrin gels were transparent in appearance and exhibited high water content, which were characteristics distinct from those of gels formed by mixtures of sHAs and fibrinogen. The potential applications of the sHA-fibrin gels were evaluated. The sHA-fibrinogen gel with a graft ratio of 3.6 (S3.6F) was examined for its ability to encapsulate and support the differentiation of ATDC5 chondrocyte-like cells. Compared with the fibrinogen-formed gel, cells cultured in the S3.6F gel exhibited increased lacunae formation; moreover, the abundance of cartilaginous extracellular matrix molecules and the expression of chondrocyte marker genes, such as aggrecan, collagen II and Sox9, were also significantly increased. Our data suggest that the three-dimensional gel formed by the sHA-fibrinogen hybrid is a better support than the fibrin gel for chondrogenesis induction.

  14. A novel fibrin gel derived from hyaluronic acid-grafted fibrinogen

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chiung L; Chen, Hui W; Wang, Tzu C; Wang, Yng J, E-mail: wang@ym.edu.tw [Institute of Biomedical Engineering, National Yang Ming University, No. 155, Sec. 2, Li-Nung St., Shih-Pai, Taipei, Taiwan 112 (China)

    2011-04-15

    Fibrinogen is a major plasma protein that forms a three-dimensional fibrin gel upon being activated by thrombin. In this study, we report the synthesis and potential applications of hybrid molecules composed of fibrinogen coupled to the reducing ends of short-chain hyaluronic acids (sHAs) by reductive amination. The grafting of sHAs to fibrinogen was verified by analyzing particle size, zeta potential and gel-electrophoretic mobility of the hybrid molecules. The sHA-fibrinogen hybrid molecules with graft ratios (sHA/fibrinogen) of up to 6.5 retained the ability to form gels in response to thrombin activation. The sHA-fibrin gels were transparent in appearance and exhibited high water content, which were characteristics distinct from those of gels formed by mixtures of sHAs and fibrinogen. The potential applications of the sHA-fibrin gels were evaluated. The sHA-fibrinogen gel with a graft ratio of 3.6 (S3.6F) was examined for its ability to encapsulate and support the differentiation of ATDC5 chondrocyte-like cells. Compared with the fibrinogen-formed gel, cells cultured in the S3.6F gel exhibited increased lacunae formation; moreover, the abundance of cartilaginous extracellular matrix molecules and the expression of chondrocyte marker genes, such as aggrecan, collagen II and Sox9, were also significantly increased. Our data suggest that the three-dimensional gel formed by the sHA-fibrinogen hybrid is a better support than the fibrin gel for chondrogenesis induction.

  15. Influences of ABO blood group, age and gender on plasma coagulation factor VIII, fibrinogen, von Willebrand factor and ADAMTS13 levels in a Chinese population.

    Science.gov (United States)

    Wang, Zongkui; Dou, Miaomiao; Du, Xi; Ma, Li; Sun, Pan; Cao, Haijun; Ye, Shengliang; Jiang, Peng; Liu, Fengjuan; Lin, Fangzhao; Zhang, Rong; Li, Changqing

    2017-01-01

    ABO blood group is a hereditary factor of plasma levels of coagulation factor VIII (FVIII) and von Willebrand factor (VWF). Age and gender have been shown to influence FVIII, VWF, fibrinogen (Fbg), and ADAMTS13 (A disintegrin and metalloprotease with thrombospondin type 1 motif, 13). We investigated the effects of ABO type, age, and gender on plasma levels of FVIII, Fbg, VWF, and ADAMTS13 in a Chinese population. A total of 290 healthy volunteers were eligible for this study. ABO blood group was determined by indirect technique. FVIII:C and Fbg were measured by clotting assays. VWF antigen (VWF:Ag), collagen-binding activity (VWF:CBA), and ADAMTS13 antigen were assessed by ELISA, whereas VWF ristocetin cofactor activity (VWF:Rcof) was performed by agglutination of platelets with ristocetin. Mean FVIII:C and VWF levels (VWF:Ag, VWF:CBA, and VWF:Rcof) were significantly higher in non-O than in O type subjects ( p  blood group, age, and gender showed different effects on plasma levels of FVIII:C, Fbg, VWF:Ag, VWF:CBA, VWF:Rcof, and ADAMTS13 antigen. These new data on a Chinese population are quite helpful to compare with other ethnic groups.

  16. Erythrocyte sedimentation rate and fibrinogen concentration of whole blood influences the cellular composition of platelet-rich plasma obtained from centrifugation methods.

    Science.gov (United States)

    Yin, Wenjing; Xu, Zhengliang; Sheng, Jiagen; Xie, Xuetao; Zhang, Changqing

    2017-09-01

    Erythrocyte sedimentation rate (ESR), which reflects the sedimentation rate of platelets, leukocytes and erythrocytes in response to centrifugal force, may influence the cellular composition of platelet-rich plasma (PRP) obtained via centrifugation methods. However, no relevant studies have substantiated this. In the present study, blood was collected from 40 healthy volunteers and used to prepare PRP with two plasma-based preparation systems [YinPRP and Plasma Rich in Growth Factor (PRGF) systems] and two buffy coat-based systems (RegenPRP and WEGOPRP systems) in a single-donor model. Volumes of PRP and platelet-poor plasma (PPP) that were removed in the preparation process were recorded. Analyses of ESR, haematocrit, C-reaction protein, coagulation, serum glucose and serum lipid of the whole blood used for PRP preparation were performed to evaluate the levels of ESR and the factors known to influence it. Whole blood analysis was performed to evaluate the cellular composition of PRP. Results demonstrated that there were marked positive correlations between the ESR of the whole blood used for PRP preparation and PPP removal efficiencies, platelet concentrations, platelet capture efficiencies and platelet enrichment factors of PRP formulations obtained from plasma-based systems, and PRP yield efficiency of RegenPRP and PPP removal efficiency of WEGOPRP. Furthermore, there were marked negative correlations between ESR and concentrations and enrichment factors of platelets, leukocytes and erythrocytes of RegenPRP. Fibrinogen concentration of the whole blood, which had a marked positive correlation with ESR, also influenced the cellular composition of PRP. These findings may increase the understanding of PRP preparation and provide substantial evidence for the individualised optimisation of PRP preparation systems used in clinical practice.

  17. Technetium-99m-human fibrinogen

    International Nuclear Information System (INIS)

    Wong, D.W.; Mishkin, F.S.

    1975-01-01

    Exogenous fibrinogen has been successfully labeled with /sup 99m/Tc using a modified electrolytic method. The exact labeling mechanism has not been determined. Experimental data suggest that the labeling process of /99m/Tc-fibrinogen is quite similar to that of /sup 99m/Tc-human serum albumin as reported earlier by Benjamin. Technetium-99m-fibrinogen is stable in human plasma or in 1 percent buffered human serum albumin. A binding efficiency of 76 percent has been achieved with approximately 25 percent clottable protein. The entire labeling procedure requires less than 1 hr of preparation time. This short labeling time in a closed system may allow development of a practical method for labeling autologous fibrinogen, thus eliminating the risk of hepatitis transmission. (U.S.)

  18. Fibrinogen concentrates for bleeding trauma patients: what is the evidence?

    DEFF Research Database (Denmark)

    Meyer, Martin; Ostrowski, S R; Windeløv, N A

    2011-01-01

    A balanced transfusion of red blood cells, fresh frozen plasma and platelets are recommended for massively bleeding trauma patients. Fibrinogen concentrates could potentially lessen or replace the need for fresh frozen plasma and/or platelet transfusions.......A balanced transfusion of red blood cells, fresh frozen plasma and platelets are recommended for massively bleeding trauma patients. Fibrinogen concentrates could potentially lessen or replace the need for fresh frozen plasma and/or platelet transfusions....

  19. Unexpected high plasma cobalamin

    DEFF Research Database (Denmark)

    Arendt, Johan F B; Nexo, Ebba

    2013-01-01

    It is well-established that more than 8% of patients examined for vitamin B12 deficiency unexpectedly have increased plasma levels of the vitamin, but so far there are no guidelines for the clinical interpretation of such findings. In this review, we summarise known associations between high plasma...... cobalamin binding proteins, transcobalamin and haptocorrin. Based on current knowledge, we suggest a strategy for the clinical interpretation of unexpected high plasma cobalamin. Since a number of the associated diseases are critical and life-threatening, the strategy promotes the concept of 'think...

  20. Anticoagulant and calcium-binding properties of high molecular weight derivatives of human fibrinogen, produced by plasmin (fragments X)

    NARCIS (Netherlands)

    Nieuwenhuizen, W.; Gravesen, M.

    1981-01-01

    Early plasmin degradation products (X fragments) of human fibrinogen were prepared in the presence of calcium-ions or EGTA, and purified on Sepharose 6B-CL. X fragments were characterized with respect to amino-terminal amino acids, polypeptide-chain composition, anticlotting properties and

  1. High energy plasma accelerators

    International Nuclear Information System (INIS)

    Tajima, T.

    1985-05-01

    Colinear intense laser beams ω 0 , kappa 0 and ω 1 , kappa 1 shone on a plasma with frequency separation equal to the electron plasma frequency ω/sub pe/ are capable of creating a coherent large longitudinal electric field E/sub L/ = mc ω/sub pe//e of the order of 1GeV/cm for a plasma density of 10 18 cm -3 through the laser beat excitation of plasma oscillations. Accompanying favorable and deleterious physical effects using this process for a high energy beat-wave accelerator are discussed: the longitudinal dephasing, pump depletion, the transverse laser diffraction, plasma turbulence effects, self-steepening, self-focusing, etc. The basic equation, the driven nonlinear Schroedinger equation, is derived to describe this system. Advanced accelerator concepts to overcome some of these problems are proposed, including the plasma fiber accelerator of various variations. An advanced laser architecture suitable for the beat-wave accelerator is suggested. Accelerator physics issues such as the luminosity are discussed. Applications of the present process to the current drive in a plasma and to the excitation of collective oscillations within nuclei are also discussed

  2. Fibrinogen titer and glycemic status in women using contraceptives

    International Nuclear Information System (INIS)

    Syed, S.; Qureshi, M.A.

    2002-01-01

    Objective: To assess the coagulation and glycemic status in Pakistani women using contraceptives. Design: The study was conducted prospectively on 70 women and compared with 10 age-matched controls. Place and Duration of Study: The study was conducted at Karachi. Period of study was 18 month. Subjects and Methods: Eighty women aged between 20-45 years selected from low socioeconomic class and poor family background were categorized in control (n=10) and oral and injectable contraceptive users (n = 70). The contraceptives used were tablet Lofemenal, injection Norigest and Norplant implant. Their blood was tested for fibrinogen titer and random blood glucose. Results: There was no appreciable difference either in fibrinogen titer or plasma glucose levels in injectable users as compared to controls, but increased incidence of high fibrinogen titer and borderline blood glucose was observed in oral contraceptive users 25% and 20 % respectively. Conclusion: It was concluded that long-term use of oral contraceptives (> 3 years) might increase the thrombotic tendency and elevate the plasma glucose levels especially in women above 30 years of age. (author)

  3. Associations of overall sitting time and TV viewing time with fibrinogen and C reactive protein: the AusDiab study.

    Science.gov (United States)

    Howard, Bethany J; Balkau, Beverley; Thorp, Alicia A; Magliano, Dianna J; Shaw, Jonathan E; Owen, Neville; Dunstan, David W

    2015-02-01

    Sedentary behaviour is associated with increased risk for all-cause and cardiovascular mortality. Plasma fibrinogen and C reactive protein (CRP)-key inflammatory and/or haemostatic markers-may contribute to this association; however, few studies have examined their relationships with sedentary behaviours. We examined associations of overall sitting and TV viewing time with fibrinogen and high-sensitivity CRP (hsCRP). Plasma fibrinogen and hsCRP were measured in 3086 Australian adults (mean age: 55±12 years) who participated in the 2004-2005 AusDiab (Australian Diabetes, Obesity and Lifestyle) study. Multiple linear regression analyses examined cross-sectional associations of self-reported overall sitting and TV viewing time (h/day) with plasma fibrinogen and hsCRP, adjusting for sociodemographic, behavioural and medical treatments and conditions as potential covariates. Overall sitting time and TV viewing time were positively associated with plasma fibrinogen (sitting: β: 0.02 g/L, 95% CI (0.01 to 0.02); TV time: 0.03 g/L (0.02 to 0.05)) and hsCRP (sitting: 2.4% (1.2% to 3.6%); TV time: 4.5% (1.7% to 7.4%)). Associations were independent of leisure-time physical activity, but after adjusting for waist circumference, they remained for fibrinogen, but for hsCRP were attenuated to the null. Interactions were observed for gender×TV (p=0.011) with fibrinogen (associations in women only) and for waist circumference×TV (p=0.084) with hsCRP (associations in low-risk only). Overall sitting time was positively associated with plasma fibrinogen and hsCRP in men and women; associations of TV viewing time with fibrinogen were observed in women only. Abdominal adiposity-mediated associations for hsCRP but not for fibrinogen. Prospective and intervention studies are needed to establish likely causality and elucidate potential mechanisms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. Fibrinogen and fibrin.

    Science.gov (United States)

    Weisel, John W

    2005-01-01

    Fibrinogen is a large, complex, fibrous glycoprotein with three pairs of polypeptide chains linked together by 29 disulfide bonds. It is 45 nm in length, with globular domains at each end and in the middle connected by alpha-helical coiled-coil rods. Both strongly and weakly bound calcium ions are important for maintenance of fibrinogen's structure and functions. The fibrinopeptides, which are in the central region, are cleaved by thrombin to convert soluble fibrinogen to insoluble fibrin polymer, via intermolecular interactions of the "knobs" exposed by fibrinopeptide removal with "holes" always exposed at the ends of the molecules. Fibrin monomers polymerize via these specific and tightly controlled binding interactions to make half-staggered oligomers that lengthen into protofibrils. The protofibrils aggregate laterally to make fibers, which then branch to yield a three-dimensional network-the fibrin clot-essential for hemostasis. X-ray crystallographic structures of portions of fibrinogen have provided some details on how these interactions occur. Finally, the transglutaminase, Factor XIIIa, covalently binds specific glutamine residues in one fibrin molecule to lysine residues in another via isopeptide bonds, stabilizing the clot against mechanical, chemical, and proteolytic insults. The gene regulation of fibrinogen synthesis and its assembly into multichain complexes proceed via a series of well-defined steps. Alternate splicing of two of the chains yields common variant molecular isoforms. The mechanical properties of clots, which can be quite variable, are essential to fibrin's functions in hemostasis and wound healing. The fibrinolytic system, with the zymogen plasminogen binding to fibrin together with tissue-type plasminogen activator to promote activation to the active enzyme plasmin, results in digestion of fibrin at specific lysine residues. Fibrin(ogen) also specifically binds a variety of other proteins, including fibronectin, albumin

  5. Reduced Transfusion During OLT by POC Coagulation Management and TEG Functional Fibrinogen: A Retrospective Observational Study.

    Science.gov (United States)

    De Pietri, Lesley; Ragusa, Francesca; Deleuterio, Annalisa; Begliomini, Bruno; Serra, Valentina

    2016-01-01

    Patients undergoing orthotopic liver transplantation are at high risk of bleeding complications. Several Authors have shown that thromboelastography (TEG)-based coagulation management and the administration of fibrinogen concentrate reduce the need for blood transfusion. We conducted a single-center, retrospective cohort observational study (Modena Polyclinic, Italy) on 386 consecutive patients undergoing liver transplantation. We assessed the impact on resource consumption and patient survival after the introduction of a new TEG-based transfusion algorithm, requiring also the introduction of the fibrinogen functional thromboelastography test and a maximum amplitude of functional fibrinogen thromboelastography transfusion cutoff (7 mm) to direct in administering fibrinogen (2012-2014, n = 118) compared with a purely TEG-based algorithm previously used (2005-2011, n = 268). After 2012, there was a significant decrease in the use of homologous blood (1502 ± 1376 vs 794 ± 717 mL, P < 0.001), fresh frozen plasma (537 ± 798 vs 98 ± 375 mL, P < 0.001), and platelets (158 ± 280 vs 75 ± 148 mL, P < 0.005), whereas the use of fibrinogen increased (0.1 ± 0.5 vs 1.4 ± 1.8 g, P < 0.001). There were no significant differences in 30-day and 6-month survival between the 2 groups. The implementation of a new coagulation management method featuring the addition of the fibrinogen functional thromboelastography test to the TEG test according to an algorithm which provides for the administration of fibrinogen has helped in reducing the need for transfusion in patients undergoing liver transplantation with no impact on their survival.

  6. Risk Factors for Postoperative Fibrinogen Deficiency after Surgical Removal of Intracranial Tumors.

    Directory of Open Access Journals (Sweden)

    Naili Wei

    Full Text Available Higher levels of fibrinogen, a critical element in hemostasis, are associated with increased postoperative survival rates, especially for patients with massive operative blood loss. Fibrinogen deficiency after surgical management of intracranial tumors may result in postoperative intracranial bleeding and severely worsen patient outcomes. However, no previous studies have systematically identified factors associated with postoperative fibrinogen deficiency. In this study, we retrospectively analyzed data from patients who underwent surgical removal of intracranial tumors in Beijing Tiantan Hospital date from 1/1/2013to12/31/2013. The present study found that patients with postoperative fibrinogen deficiency experienced more operative blood loss and a higher rate of postoperative intracranial hematoma, and they were given more blood transfusions, more plasma transfusions, and were administered larger doses of hemocoagulase compared with patients without postoperative fibrinogen deficiency. Likewise, patients with postoperative fibrinogen deficiency had poorer extended Glasgow Outcome Scale (GOSe, longer hospital stays, and greater hospital expenses than patients without postoperative fibrinogen deficiency. Further, we assessed a comprehensive set of risk factors associated with postoperative fibrinogen deficiency via multiple linear regression. We found that body mass index (BMI, the occurrence of postoperative intracranial hematoma, and administration of hemocoagulasewere positively associated with preoperative-to-postoperative plasma fibrinogen consumption; presenting with a malignant tumor was negatively associated with fibrinogen consumption. Contrary to what might be expected, intraoperative blood loss, the need for blood transfusion, and the need for plasma transfusion were not associated with plasma fibrinogen consumption. Considering our findings together, we concluded that postoperative fibrinogen deficiency is closely associated with

  7. Effect of vitamins C and E alone and in combination with each other on LDL and fibrinogen in streptozotocin induced diabetic rats

    International Nuclear Information System (INIS)

    Talat, A.; Khan, T.B.; Mahmood, S.

    2011-01-01

    Diabetes mellitus is a heterogeneous group of disorders, manifested by raised plasma glucose concentration and disturbances of glucose metabolism Diabetes mellitus is a complex of metabolic disorders affecting different systems of body. The main etiology of mortality and high percentage of morbidity in patients with diabetes mellitus is atherosclerosis. The vascular endothelium overlying lesion - prone arterial sites shows increased permeability to plasma proteins, LDL and fibrinogen. High plasma fibrinogen concentration in adults is associated with elevated risk of coronary heart disease and stroke. Treatment with antioxidants like vitamin C and vitamin E reduces diabetic complications. The aim of this study was to determine the effect of antioxidants vitamin C and E in lowering the fibrinogen and LDL levels. Present study was conducted on 48 albino rats. They were divided into four groups. Dia-betes was induced in all rats by giving streptozotocin 65 mg/kg intraperitoneally. First group was control diabetic. Second group was given vitamin C in a dose of 150 mg/kg b.w/day and third group was given vita-min E in a dose of 100 mg/kg b.w/day. Fourth group was given vitamin C with vitamin E intraperitoneally in the same doses. Effects of vitamin C and E were observed on serum LDL and plasma fibrinogen level by using commercially available kits. LDL cholesterol was decreased in groups B, C and D as compared to group A. Fibrinogen level was decreased in - group B and D and increased in group C. Vitamin C alone and in combination with vitamin E help in ameliorating atherosclerosis by decreasing LDL and fibrinogen levels. Vitamin E lowers LDL level but not fibrinogen level. There is a synergistic action of vitamin E and C in lowering fibrinogen and LDL level. (author)

  8. Fibrinogen concentrate in bleeding patients

    DEFF Research Database (Denmark)

    Wikkelsø, Anne; Lunde, Jens; Johansen, Mathias

    2013-01-01

    Hypofibrinogenaemia is associated with increased morbidity and mortality, but the optimal treatment level, the use of preemptive treatment and the preferred source of fibrinogen remain disputed. Fibrinogen concentrate is increasingly used and recommended for bleeding with acquired haemostatic...

  9. Evaluation of in vivo stability of Ga-67 labeled human fibrinogen

    International Nuclear Information System (INIS)

    Takahashi, Keietsu; Takahashi, Jun; Okano, Sakae; Kurami, Miki; Ueda, Nobuo; Hazue, Masaaki

    1987-01-01

    Human fibrinogen (Fib) was conjugated with a large number of deferoxamine (DFO) through dialdehyde starch (DAS), and the conjugate (Fib-DAS-DFO) was labeled with Ga-67. Thus labeled fibrinogen (Ga-67-Fib-DAS-DFO) showed a high labeling efficiency (more than 90 %) and retained clottability (more than 80 %). For the evaluation of plasma radioactive species, blood samples were collected at various time periods after the i.v. administration of Ga-67-Fib-DAS-DFO into rats, and the plasma radioactivity was analyzed by high performance liquid chromatography (HPLC) and electrophoresis (EP). The radioactive HPLC elution profiles for the plasma samples were identical with that of the original Ga-67-Fib-DAS-DFO; the EP patterns for the plasma were also identical with the original one, and no radioactive species, except for Ga-67-Fib-DAS-DFO, was detected by HPLC or EP. Furthermore, the presence of transferrin in the labeling formulation did not affect the labeling yield of Ga-67-Fib-DAS-DFO indicating that the transchelation of Ga-67 from DFO on Fib to transferrin is negligible. These findings indicated that Ga-67 is tightly bound to Fib-DAS-DFO in blood, and the Ga-67-Fib-DAS-DFO can be efficiently trapped by clots as the result of its high retention of physiological activities as fibrinogen. (author)

  10. High-frequency plasma oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Akhiezer, A I; Fainberg, Y B; Sitenko, A G; Stepanov, K; Kurilko, V; Gorbatenko, M; Kirochkin, U [Academy of Sciences of the Ukrainian SSR (USSR)

    1958-07-01

    It is well known that the electrical conductivity of a plasma, the ion-electron equilibration time, and the time required to heat the electron component of the plasma all increase greatly with increasing temperature. Consequently, the usual method of Joule heating a plasma may be difficult to apply in the region of high temperatures (> 10{sup 6}K), especially if the plasma current alone, without any additional measures, is used to generate magnetic fields for the confinement of the plasma. Therefore, it is of interest to study methods of plasma heating that do not directly use Joule heat, especially methods by which energy is directly supplied to the ion component during the time between collisions. Some of these methods make use of ionic resonance as well as other resonance phenomena which can occur in plasma in an external magnetic field. This paper deals with certain aspects of the theory of high-frequency plasma oscillations.

  11. High-temperature plasma physics

    International Nuclear Information System (INIS)

    Furth, H.P.

    1988-03-01

    Both magnetic and inertial confinement research are entering the plasma parameter range of fusion reactor interest. This paper reviews the individual and common technical problems of these two approaches to the generation of thermonuclear plasmas, and describes some related applications of high-temperature plasma physics

  12. Containment of high temperature plasmas

    International Nuclear Information System (INIS)

    Bass, R.W.; Ferguson, H.R.P.; Fletcher, H. Jr.; Gardner, J.; Harrison, B.K.; Larsen, K.M.

    1973-01-01

    Apparatus is described for confining a high temperature plasma which comprises: 1) envelope means shaped to form a toroidal hollow chamber containing a plasma, 2) magnetic field line generating means for confining the plasma in a smooth toroidal shape without cusps. (R.L.)

  13. Fibrinogen concentrate for bleeding - a systematic review

    DEFF Research Database (Denmark)

    Lunde, J; Stensballe, J; Wikkelsø, A

    2014-01-01

    Fibrinogen concentrate as part of treatment protocols increasingly draws attention. Fibrinogen substitution in cases of hypofibrinogenaemia has the potential to reduce bleeding, transfusion requirement and subsequently reduce morbidity and mortality. A systematic search for randomised controlled...... trials (RCTs) and non-randomised studies investigating fibrinogen concentrate in bleeding patients was conducted up to November 2013. We included 30 studies of 3480 identified (7 RCTs and 23 non-randomised). Seven RCTs included a total of 268 patients (165 adults and 103 paediatric), and all were...... determined to be of high risk of bias and none reported a significant effect on mortality. Two RCTs found a significant reduction in bleeding and five RCTs found a significant reduction in transfusion requirements. The 23 non-randomised studies included a total of 2825 patients, but only 11 of 23 studies...

  14. Fibrates suppress fibrinogen gene expression in rodents via activation of the peroxisome proliferator-activated receptor-α

    NARCIS (Netherlands)

    Kockx, M.; Gervois, P.P.; Poulain, P.; Derudas, B.; Peters, J.M.; Gonzalez, F.J.; Princen, H.M.G.; Kooistra, T.; Staels, B.

    1999-01-01

    Plasma fibrinogen levels have been identified as an important risk factor for cardiovascular diseases. Among the few compounds known to lower circulating fibrinogen levels in humans are certain fibrates. We have studied the regulation of fibrinogen gene expression by fibrates in rodents. Treatment

  15. Analysis of the safety and pharmacodynamics of human fibrinogen concentrate in animals

    Energy Technology Data Exchange (ETDEWEB)

    Beyerle, Andrea, E-mail: andrea.beyerle@cslbehring.com [CSL Behring GmbH, Preclinical Research and Development, Marburg (Germany); Nolte, Marc W. [CSL Behring GmbH, Preclinical Research and Development, Marburg (Germany); Solomon, Cristina [CSL Behring GmbH, Medical Affairs, Marburg (Germany); Department of Anaesthesiology, Perioperative Medicine and General Intensive Care, Paracelsus Medical University, Salzburg (Austria); Herzog, Eva; Dickneite, Gerhard [CSL Behring GmbH, Preclinical Research and Development, Marburg (Germany)

    2014-10-01

    Fibrinogen, a soluble 340 kDa plasma glycoprotein, is critical in achieving and maintaining hemostasis. Reduced fibrinogen levels are associated with an increased risk of bleeding and recent research has investigated the efficacy of fibrinogen concentrate for controlling perioperative bleeding. European guidelines on the management of perioperative bleeding recommend the use of fibrinogen concentrate if significant bleeding is accompanied by plasma fibrinogen levels less than 1.5–2.0 g/l. Plasma-derived human fibrinogen concentrate has been available for therapeutic use since 1956. The overall aim of the comprehensive series of non-clinical investigations presented was to evaluate i) the pharmacodynamic and pharmacokinetic characteristics and ii) the safety and tolerability profile of human fibrinogen concentrate Haemocomplettan P® (RiaSTAP®). Pharmacodynamic characteristics were assessed in rabbits, pharmacokinetic parameters were determined in rabbits and rats and a safety pharmacology study was performed in beagle dogs. Additional toxicology tests included: single-dose toxicity tests in mice and rats; local tolerance tests in rabbits; and neoantigenicity tests in rabbits and guinea pigs following the introduction of pasteurization in the manufacturing process. Human fibrinogen concentrate was shown to be pharmacodynamically active in rabbits and dogs and well tolerated, with no adverse events and no influence on circulation, respiration or hematological parameters in rabbits, mice, rats and dogs. In these non-clinical investigations, human fibrinogen concentrate showed a good safety profile. This data adds to the safety information available to date, strengthening the current body of knowledge regarding this hemostatic agent. - Highlights: • A comprehensive series of pre-clinical investigations of human fibrinogen concentrate. • Human fibrinogen concentrate was shown to be pharmacodynamically active. • Human fibrinogen concentrate was well tolerated

  16. Analysis of the safety and pharmacodynamics of human fibrinogen concentrate in animals

    International Nuclear Information System (INIS)

    Beyerle, Andrea; Nolte, Marc W.; Solomon, Cristina; Herzog, Eva; Dickneite, Gerhard

    2014-01-01

    Fibrinogen, a soluble 340 kDa plasma glycoprotein, is critical in achieving and maintaining hemostasis. Reduced fibrinogen levels are associated with an increased risk of bleeding and recent research has investigated the efficacy of fibrinogen concentrate for controlling perioperative bleeding. European guidelines on the management of perioperative bleeding recommend the use of fibrinogen concentrate if significant bleeding is accompanied by plasma fibrinogen levels less than 1.5–2.0 g/l. Plasma-derived human fibrinogen concentrate has been available for therapeutic use since 1956. The overall aim of the comprehensive series of non-clinical investigations presented was to evaluate i) the pharmacodynamic and pharmacokinetic characteristics and ii) the safety and tolerability profile of human fibrinogen concentrate Haemocomplettan P® (RiaSTAP®). Pharmacodynamic characteristics were assessed in rabbits, pharmacokinetic parameters were determined in rabbits and rats and a safety pharmacology study was performed in beagle dogs. Additional toxicology tests included: single-dose toxicity tests in mice and rats; local tolerance tests in rabbits; and neoantigenicity tests in rabbits and guinea pigs following the introduction of pasteurization in the manufacturing process. Human fibrinogen concentrate was shown to be pharmacodynamically active in rabbits and dogs and well tolerated, with no adverse events and no influence on circulation, respiration or hematological parameters in rabbits, mice, rats and dogs. In these non-clinical investigations, human fibrinogen concentrate showed a good safety profile. This data adds to the safety information available to date, strengthening the current body of knowledge regarding this hemostatic agent. - Highlights: • A comprehensive series of pre-clinical investigations of human fibrinogen concentrate. • Human fibrinogen concentrate was shown to be pharmacodynamically active. • Human fibrinogen concentrate was well tolerated

  17. Is it acceptable to use coagulation plasma samples stored at room temperature and 4°C for 24 hours for additional prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, and D-dimer testing?

    Science.gov (United States)

    Rimac, V; Coen Herak, D

    2017-10-01

    Coagulation laboratories are faced on daily basis with requests for additional testing in already analyzed fresh plasma samples. This prompted us to examine whether plasma samples stored at room temperature (RT), and 4°C for 24 hours can be accepted for additional prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen (Fbg), antithrombin (AT), and D-dimer testing. We measured PT, aPTT, Fbg in 50 and AT in 30 plasma samples with normal and pathological values, within 4 hours of blood collection (baseline results) and after 24-hours storage at RT (primary tubes), and 4°C (aliquots). D-dimer stability was investigated in 20 samples stored in primary tubes at 4°C. No statistically significant difference between baseline results and results in samples stored at RT and 4°C was observed for PT (P=.938), aPTT (P=.186), Fbg (P=.962), AT (P=.713), and D-dimers (P=.169). The highest median percentage changes were found for aPTT, being more pronounced for samples stored at 4°C (13.0%) than at RT (8.7%). Plasma samples stored both at RT and 4°C for 24 hours are acceptable for additional PT, Fbg, and AT testing. Plasma samples stored 24 hours in primary tubes at 4°C are suitable for D-dimer testing. © 2017 John Wiley & Sons Ltd.

  18. Fibrinogen assays: a collaborative study of six different methods. C.I.S.M.E.L. Comitato Italiano per la Standardizzazione dei Metodi in Ematologia e Laboratorio.

    Science.gov (United States)

    Palareti, G; Maccaferri, M; Manotti, C; Tripodi, A; Chantarangkul, V; Rodeghiero, F; Ruggeri, M; Mannucci, P M

    1991-05-01

    This collaborative study, organized by the Hemostasis Subcommittee of C.I.S.M.E.L., evaluated the accuracy, precision, and comparability of the following six widely used fibrinogen assays: total clottable fibrinogen (Blombäck and Blombäck), clotting time (Von Clauss), turbidimetry (Ellis and Stransky), Chromotime System, prothrombin time (PT)-derived, and radial immunodiffusion (RID). The same frozen samples, with normal and high contents of fibrinogen, were examined in four laboratories. The methods were calibrated with an internal standard whose fibrinogen content was determined gravimetrically. Both the Von Clauss and the RID methods were reliable, accurate, and precise, if adequate calibration was used. The PT-derived method was highly reproducible, but had some problems with accuracy. We demonstrate that an adequate calibration procedure is indispensable for reliable fibrinogen measurements whatever method is used. Because neither the calibration procedures proposed by the manufacturers nor the use of lyophilized commercial plasmas is adequate for this purpose, we urge that an international standard for fibrinogen measurement be promptly established.

  19. Conformational changes of fibrinogen in dispersed carbon nanotubes

    Directory of Open Access Journals (Sweden)

    Park SJ

    2012-08-01

    Full Text Available Sung Jean Park,1 Dongwoo Khang21College of Pharmacy, Gachon University, Yeonsu-gu, Incheon, South Korea; 2School of Nano and Advanced Materials Science Engineering and Center for PRC and RIGET, Gyeongsang National University, Jinju, South KoreaAbstract: The conformational changes of plasma protein structures in response to carbon nanotubes are critical for determining the nanotoxicity and blood coagulation effects of carbon nanotubes. In this study, we identified that the functional intensity of carboxyl groups on carbon nanotubes, which correspond to the water dispersity or hydrophilicity of carbon nanotubes, can induce conformational changes in the fibrinogen domains. Also, elevation of carbon nanotube density can alter the secondary structures (ie, helices and beta sheets of fibrinogen. Furthermore, fibrinogen that had been in contact with the nanoparticle material demonstrated a different pattern of heat denaturation compared with free fibrinogen as a result of a variation in hydrophilicity and concentration of carbon nanotubes. Considering the importance of interactions between carbon nanotubes and plasma proteins in the drug delivery system, this study elucidated the correlation between nanoscale physiochemical material properties of carbon nanotubes and associated structural changes in fibrinogen.Keywords: carbon nanotubes, fibrinogen, nanotoxicity, conformational change, denaturation

  20. Release of peptides from Fibrinogen in vitro and in vivo

    International Nuclear Information System (INIS)

    Weibel, S.

    1986-01-01

    The dissertation deals experimentally with the following problem fields: The attempt was made to obtain extremely pure, native peptides from fibrinogen with micropreparation with the help of high-pressure liquid chromatography (HPLC); a HPLC-pure antigen which could be labelled (DAT-FPA) was also to be produced and a HPLC-purified, labelled antigen (J 125 DAT-FPA) for the radioimmunoassay was to be prepared. By applying HPLC-purified FPA-material to immunise rabbits, a highly specific antibody against FPA was obtained, and the radioimmunoassay was decisively improved. Furthermore, a method with a high recovery rate specific for the A-peptides could be found. A procedure was developed which is able to separate the modifications from the plasma from one another and to prove them specifically in ng-quantities. This is the first time that the sensitive method of high-pressure liquid chromatography is used to observe the effects of the snake venom enzymes on fibrinogen over a period of 20 hrs. The kinetics of intravenously administered J 123 DAT-FPA and, in comparison, J 123 FPB β 15-42 in vivo in rabbits with the help of a scintiscanning method, was investigated and the distribution in the organism and the ways of elimination were determined. (orig./MG) [de

  1. Extraction, radioiodination, and in vivo catabolism of equine fibrinogen

    International Nuclear Information System (INIS)

    Coyne, C.P.; Hornof, W.J.; Kelly, A.B.; O'Brien, T.R.; DeNardo, S.J.

    1985-01-01

    Equine fibrinogen was isolated and aliquots were stored frozen at -70 C before radiolabeling with 125I (half-life = 60.2 days; gamma = 35 keV, using monochloroiodine reagent. Radioiodination efficiencies were 49% to 53%, resulting in a labeled product with 98% protein-bound activity and 91% clottable radioactivity. In 6 equine in vivo investigations, plasma half-lives of 125I-labeled fibrinogen were from 4.1 to 5.2 days, corresponding to a mean daily plasma elimination rate of approximately 15%

  2. Rapidly produced /sup 125/I labelled autologous fibrinogen: in vitro properties and preliminary metabolic studies in man

    Energy Technology Data Exchange (ETDEWEB)

    Hawker, R J; Hawker, L M [Birmingham Univ. (UK)

    1976-06-01

    The properties of fibrinogen extracted by a precipitation method using glycine at ambient temperatures near neutral pH are described. The simple and reproducible method gave a 73% yield of high purity plasminogen-free fibrinogen in 45 minutes from small volumes of plasma. The protein extract was labelled with /sup 125/I using chloramine-T under conditions optimal for fibrinogen stability. The extraction procedure, radio-iodination, desalting, and sterilization take only 70 minutes for completion from the time donor blood is received in the laboratory. The methods, using a specially developed extraction vessel and desalting/sterilizing column, can be used in a small hospital laboratory. Autologous fibrinogen can thus be extracted from patients' blood, eliminating the risk of transmitting hepatitis when it is re-administered. The autologous material, which is 97% clottable and contains less than 0.05% free iodide, is being routinely used as a diagnostic tool in the detection of deep vein thrombosis. The high purity of the preparation facilitates metabolic studies and in vitro experimental work. In vivo results showed a mean half-life in three normal volunteers of 3.95 days and a catabolic rate of 25.23% per day with the extravascular space estimated as 24.86%. In 30 surgical patients an expected reduced half-life in plasma was determined with a mean of 3.1 days.

  3. [Perioperative fibrinogen concentrations in cardiac surgery with cardiopulmonary bypass].

    Science.gov (United States)

    Uji, Makiko; Terada, Yuki; Noguchi, Teruo; Nishida, Takaya; Hasuwa, Kyoko; Shinohara, Kozue; Kumano, Hotaka; Ishimura, Naoko; Nishiwada, Makoto

    2012-08-01

    Patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) need many blood products due to deficiency of coagulation factors. Blood transfusion therapy in patients with excessive bleeding after CPB is generally empiric. We checked and studied the fibrinogen concentration and transfusion, as well as bleeding amount in the perioperative period. The study was approved by our institutional ethics committee. Thirty patients were studied. Blood samples were obtained at the induction of anesthesia (before CPB), at the end of CPB, at the end of operation, and on the next morning, or before the patient was given fresh frozen plasma in the intensive care unit. For all cases, fibrinogen concentration and platelet concentration were lowest at the end of CPB. Fibrinogen concentration rose up to before CPB level on the next morning. The group in which fibrinogen concentration was less than 150 mg x dl(-1) at the end of CPB consumed more blood products than the group with fibrinogen concentration of over 150 mg x dl(-1). Blood transfusion therapy based on fibrinogen concentration is needed to maintain adequacy of the perioperative blood transfusion and blood conservation in cardiac surgery.

  4. Fibrinogen function is impaired in whole blood from patients with cyanotic congenital heart disease

    DEFF Research Database (Denmark)

    Jensen, A S; Johansson, Pär I.; Bochsen, Louise

    2013-01-01

    haemoptysis. METHODS: In a prospective study 75 adult CCHD patients had haematocrit, platelet count, and plasma fibrinogen concentration examined. Furthermore thrombelastography(TEG) as well as TEG Functional Fibrinogen(TEG FF) assay evaluating fibrinogen function(FLEV) was performed. Data were compared...... with historical data regarding previous haemoptysis in CCHD patients. RESULTS: Haematocrit was 57±8% and platelet counts in the lower normal range. TEG revealed a hypocoagulable condition with impaired clot formation. TEG values were correlated to haematocrit, indicating that elevated haematocrit causes impaired....... CONCLUSION: Patients with CCHD are hypocoagulable mainly due to impaired fibrinogen function. Despite a low platelet count, platelet function does not seem to be severely affected in CCHD patients. Haemostasis, and especially fibrinogen function, is negatively affected by elevated haematocrit, and fibrinogen...

  5. Consumption of 125I labelled fibrinogen in normal subjects

    International Nuclear Information System (INIS)

    Langer, B.; Camargo, E.E.; Reis, J.M.M. dos; Carvalho, N.; Leao, L.E.P.

    1978-01-01

    The metabolism of iodine- 125 labeled human fibrinogen is studied by using three different sets of the radiopharmaceutical (0.9, 1.3 and 1.84 iodine atoms/fibrinogen molecule ratios) in 19 normal subjects. An aliquot of 40 μCi of fibrinogem- 125 I is injected in each subject, on normal dietary conditions and blood samples are withdrawn at 30, 60, 180, 36 and 720 minutes after the injection and, thereafter, one daily sample during 10 days. The compartmental distribution of the tracer is defined by plotting plasma and serum sample counts on a semilogarithmic graph paper. A rapid phase and 3 compartments are obtained. A 'rapid' consumption half-life and a 'real' consumption half-life are defined. The fibrinogen clottability is followed up to the last blood sample by checking the ratios of serum and plasma radioactivities [pt

  6. CONFINEMENT OF HIGH TEMPERATURE PLASMA

    Science.gov (United States)

    Koenig, H.R.

    1963-05-01

    The confinement of a high temperature plasma in a stellarator in which the magnetic confinement has tended to shift the plasma from the center of the curved, U-shaped end loops is described. Magnetic means are provided for counteracting this tendency of the plasma to be shifted away from the center of the end loops, and in one embodiment this magnetic means is a longitudinally extending magnetic field such as is provided by two sets of parallel conductors bent to follow the U-shaped curvature of the end loops and energized oppositely on the inside and outside of this curvature. (AEC)

  7. High Throughput Plasma Water Treatment

    Science.gov (United States)

    Mujovic, Selman; Foster, John

    2016-10-01

    The troublesome emergence of new classes of micro-pollutants, such as pharmaceuticals and endocrine disruptors, poses challenges for conventional water treatment systems. In an effort to address these contaminants and to support water reuse in drought stricken regions, new technologies must be introduced. The interaction of water with plasma rapidly mineralizes organics by inducing advanced oxidation in addition to other chemical, physical and radiative processes. The primary barrier to the implementation of plasma-based water treatment is process volume scale up. In this work, we investigate a potentially scalable, high throughput plasma water reactor that utilizes a packed bed dielectric barrier-like geometry to maximize the plasma-water interface. Here, the water serves as the dielectric medium. High-speed imaging and emission spectroscopy are used to characterize the reactor discharges. Changes in methylene blue concentration and basic water parameters are mapped as a function of plasma treatment time. Experimental results are compared to electrostatic and plasma chemistry computations, which will provide insight into the reactor's operation so that efficiency can be assessed. Supported by NSF (CBET 1336375).

  8. Solute removal capacity of high cut-off membrane plasma separators.

    Science.gov (United States)

    Ohkubo, Atsushi; Kurashima, Naoki; Nakamura, Ayako; Miyamoto, Satoko; Iimori, Soichiro; Rai, Tatemitsu

    2013-10-01

    In vitro blood filtration was performed by a closed circuit using high cut-off membrane plasma separators, EVACURE EC-2A10 (EC-2A) and EVACURE EC-4A10 (EC-4A). Samples were obtained from sampling sites before the plasma separator, after each plasma separator, and from the ultrafiltrate of each separator. The sieving coefficient (S.C.) of total protein (TP), albumin (Alb), IgG, interleukin-6 (IL-6), interleukin-8 (IL-8), tumor necrosis factor-α (TNF-α), fibrinogen (Fib), antithrombin III (AT-III), and coagulation factor XIII (FXIII) were calculated. The S.C. of each solute using EC-2A and EC-A4 were as follows; TP: 0.25 and 0.56, Alb: 0.32 and 0.73, IgG: 0.16 and 0.50, IL-6:0.73 and 0.95, IL-8:0.85 and 0.82, TNF-α: 1.07 and 0.99, Fib: 0 and 0, FXIII: 0.07 and 0.17, respectively. When compared with the conventional type of membrane plasma separators, EVACURE could efficiently remove cytokines while retaining coagulation factors such as fibrinogen. Moreover, EC-2A prevented protein loss, whereas EC-4A could remove approximately 50% of IgG. © 2013 The Authors. Therapeutic Apheresis and Dialysis © 2013 International Society for Apheresis.

  9. Fibrinogen in trauma, an evaluation of thrombelastography and rotational thromboelastometry fibrinogen assays

    DEFF Research Database (Denmark)

    Meyer, Martin A S; Ostrowski, Sisse R; Sørensen, Anne Marie

    2015-01-01

    BACKGROUND: Identifying hypofibrinogenemia in trauma is important. The optimal method of fibrinogen determination is unknown. We therefore evaluated fibrinogen levels determined by two whole blood viscoelastic hemostatic assays, thrombelastography functional fibrinogen (FF) and rotational thrombo...

  10. Specific cell components of Bacteroides gingivalis mediate binding and degradation of human fibrinogen

    International Nuclear Information System (INIS)

    Lantz, M.S.; Allen, R.D.; Vail, T.A.; Switalski, L.M.; Hook, M.

    1991-01-01

    Bacteroides (Porphyromonas) gingivalis, which has been implicated as an etiologic agent in human periodontal diseases, has been shown to bind and degrade human fibrinogen. B. gingivalis strains bind fibrinogen reversibly and with high affinity and bind to a specific region of the fibrinogen molecule that appears to be located between the D and E domains. The authors now report that human fibrinogen is bound and then degraded by specific B. gingivalis components that appear to be localized at the cell surface. Fibrinogen binding to bacterial cells occurred at 4, 22, and 37 degree C. A functional fibrinogen-binding component (M r , 150 000) was identified when sodium dodecyl sulfate-solubilized bacteria were fractionated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, transferred to nitrocellulose membranes, and probed with 125 I-fibrinogen. Fibrinogen degradation did not occur at 4 degree C but did occur at 22 and 37 degree C. When bacteria and iodinated fibrinogen were incubated at 37 degree C, two major fibrinogen fragments (M r , 97 000 and 50 000) accumulated in incubation mixture supernatant fractions. Two major fibrinogen-degrading components (M r , 120 000 and 150 000) have been identified by sodium dodecyl sulfate-polyacrylamide gel electrophoresis in substrate-containing gels. Fibrinogen degradation by the M r -120 000 and -150 000 proteases was enhanced by reducing agents, completely inhibited by N-α-p-tosyl-L-lysyl chloromethyl ketone, and partially inhibited by n-ethyl maleimide, suggesting that these enzymes are thiol-dependent proteases with trypsinlike substrate specificity. The fibrinogen-binding component could be separated from the fibrinogen-degrading components by selective solubilization of bacteria in sodium deoxycholate

  11. Specific cell components of Bacteroides gingivalis mediate binding and degradation of human fibrinogen

    Energy Technology Data Exchange (ETDEWEB)

    Lantz, M.S.; Allen, R.D.; Vail, T.A.; Switalski, L.M.; Hook, M. (Univ. of Alabama at Birmingham (USA))

    1991-01-01

    Bacteroides (Porphyromonas) gingivalis, which has been implicated as an etiologic agent in human periodontal diseases, has been shown to bind and degrade human fibrinogen. B. gingivalis strains bind fibrinogen reversibly and with high affinity and bind to a specific region of the fibrinogen molecule that appears to be located between the D and E domains. The authors now report that human fibrinogen is bound and then degraded by specific B. gingivalis components that appear to be localized at the cell surface. Fibrinogen binding to bacterial cells occurred at 4, 22, and 37{degree}C. A functional fibrinogen-binding component (M{sub r}, 150 000) was identified when sodium dodecyl sulfate-solubilized bacteria were fractionated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, transferred to nitrocellulose membranes, and probed with {sup 125}I-fibrinogen. Fibrinogen degradation did not occur at 4{degree}C but did occur at 22 and 37{degree}C. When bacteria and iodinated fibrinogen were incubated at 37{degree}C, two major fibrinogen fragments (M{sub r}, 97 000 and 50 000) accumulated in incubation mixture supernatant fractions. Two major fibrinogen-degrading components (M{sub r}, 120 000 and 150 000) have been identified by sodium dodecyl sulfate-polyacrylamide gel electrophoresis in substrate-containing gels. Fibrinogen degradation by the M{sub r}-120 000 and -150 000 proteases was enhanced by reducing agents, completely inhibited by N-{alpha}-p-tosyl-L-lysyl chloromethyl ketone, and partially inhibited by n-ethyl maleimide, suggesting that these enzymes are thiol-dependent proteases with trypsinlike substrate specificity. The fibrinogen-binding component could be separated from the fibrinogen-degrading components by selective solubilization of bacteria in sodium deoxycholate.

  12. High current plasma electron emitter

    International Nuclear Information System (INIS)

    Fiksel, G.; Almagri, A.F.; Craig, D.

    1995-07-01

    A high current plasma electron emitter based on a miniature plasma source has been developed. The emitting plasma is created by a pulsed high current gas discharge. The electron emission current is 1 kA at 300 V at the pulse duration of 10 ms. The prototype injector described in this paper will be used for a 20 kA electrostatic current injection experiment in the Madison Symmetric Torus (MST) reversed-field pinch. The source will be replicated in order to attain this total current requirement. The source has a simple design and has proven very reliable in operation. A high emission current, small size (3.7 cm in diameter), and low impurity generation make the source suitable for a variety of fusion and technological applications

  13. High temperature divertor plasma operation

    International Nuclear Information System (INIS)

    Ohyabu, Nobuyoshi.

    1991-02-01

    High temperature divertor plasma operation has been proposed, which is expected to enhance the core energy confinement and eliminates the heat removal problem. In this approach, the heat flux is guided through divertor channel to a remote area with a large target surface, resulting in low heat load on the target plate. This allows pumping of the particles escaping from the core and hence maintaining of the high divertor temperature, which is comparable to the core temperature. The energy confinement is then determined by the diffusion coefficient of the core plasma, which has been observed to be much lower than the thermal diffusivity. (author)

  14. C-reactive protein and fibrinogen of bedridden older patients in a six-month vitamin D supplementation trial.

    Science.gov (United States)

    Bjorkman, M P; Sorva, A J; Tilvis, R S

    2009-05-01

    To elucidate the association between vitamin D status, C-reactive protein (CRP) and fibrinogen. Secondary analysis of a randomised double-blind placebo controlled trial. Four longterm care hospitals (1215 beds) in Helsinki, Finland. 218 long-term inpatients aged over 65 years. Eligible patients (n = 218) were randomized to receive 0 IU/d, 400 IU/d, or 1200 IU/d cholecalciferol for six months. Plasma 25-hydroxyvitamin D (25-OHD), parathyroid hormone (PTH), high sensitive CRP, fibrinogen, amino-terminal propeptide of type I procollagen (PINP), and carboxy-terminal telopeptide of type I collagen (ICTP) were measured. The patients were aged (84.5 +/- 7.5 years), vitamin D deficient (25-OHD = 23 +/- 10 nmol/l), chronically bedridden and in stable general condition. The mean baseline CRP and fibrinogen were 10.86 mg/l (0.12 mg/l - 125.00 mg/l) and 4,7 g/l (2.3 g/l - 8.6 g/l), respectively. CRP correlated with ICTP (r = 0.217, p = 0.001), but not with vitamin D status. Supplementation significantly increased 25-OHD concentrations, but the changes in CRP and fibrinogen were insignificant and inconsistent. The post-trial CRP concentrations (0.23 mg/l -138.00 mg/l) correlated with ICTP (r = 0.156, p bedridden older patients.

  15. The consumption of fibrinogen during pregnancy

    International Nuclear Information System (INIS)

    Kuijpers, J.C.

    1982-01-01

    The aim of this thesis is to investigate the consumption of fibrinogen during pregnancy, under the influence of intravascular coagulopathy. The question is, in which manner and to what degree does intravascular coagulopathy occur during the normal pregnancy and in pregnancy induced hypertension. The measurement of the biological half life of fibrinogen is performed using I 125 labelled fibrinogen. A calculation is given for the fetal radiation dose during this measurement, which is shown to be no greater than that which occurs from various natural sources of radiation. The stability of the coupling of I 125 to the fibrinogen preparation used was investigated. Nearly 93% was bound to the intact fibrinogen fraction, 5% to the non-clotting fibrinogen, 1% to the albumin and 1% appeared as free I 125 . After intravenous injection of the I 125 -fibrinogen preparation, these proportions changed a little in favour of the clottable fibrinogen fraction. (Auth.)

  16. Quantitative Proteomic Approach Targeted to Fibrinogen β Chain in Tissue Gastric Carcinoma

    Directory of Open Access Journals (Sweden)

    Ombretta Repetto

    2018-03-01

    Full Text Available Elevated plasma fibrinogen levels and tumor progression in patients with gastric cancer (GC have been largely reported. However, distinct fibrinogen chains and domains have different effects on coagulation, inflammation, and angiogenesis. The aim of this study was to characterize fibrinogen β chain (FGB in GC tissues. Retrospectively we analyzed the data of matched pairs of normal (N and malignant tissues (T of 28 consecutive patients with GC at diagnosis by combining one- and two-dimensional electrophoresis (1DE and 2DE with immunoblotting and mass spectrometry together with two-dimensional difference in gel electrophoresis (2D-DIGE. 1DE showed bands of the intact FGB at 50 kDa and the cleaved forms containing the fragment D at ~37–40 kDa, which corresponded to 19 spots in 2DE. In particular, spot 402 at ~50 kDa and spots 526 and 548 at ~37 kDa were of interest by showing an increased expression in tumor tissues. A higher content of spot 402 was associated with stomach antrum, while spots 526 and 548 amounts correlated with corpus and high platelet count (>208 × 109/L. The quantification of FGB and cleaved products may help to further characterize the interconnections between GC and platelet/coagulation pathways.

  17. The changes in the fibrinogen concentration and coagulation pathways in winter and summer in cattle

    Directory of Open Access Journals (Sweden)

    ameneh khoshvaghti

    2013-08-01

    Full Text Available Fibrinogen is an important coagulation factor and a positive acute phase protein and its levels increases in cases of inflammation infection and stress. The present research was done to determine whether the fibrinogen concentration, prothrombin time (PT and activated partial thromboplastin time (APTT can be affected by seasonal changes. In this study, the blood of ten apparently healthy cows from around Yasouj city were taken under aseptic conditions and, then the plasma was separated. The fibrinogen concentration, was assayed by sedimentation refractometry method, PT and APTT were measurement by coagolometric method. The statistical analysis indicated that there was significant difference between the mean concentration of fibrinogen in summer and winter (P0.05. It is concluded that seasonal changes can affect the fibrinogen concentration but does no affect PT and APTT significantly.

  18. Evaluation of C-Reactive Protein and Fibrinogen in Patients with Chronic and Aggressive Periodontitis: A Clinico-Biochemical Study.

    Science.gov (United States)

    Chandy, Swaroop; Joseph, Kiran; Sankaranarayanan, Anila; Issac, Annie; Babu, George; Wilson, Bobby; Joseph, Jumol

    2017-03-01

    Periodontal disease is characterised by chronic infection and inflammation in periodontal tissues leading to destruction of alveolar bone with subsequent tooth loss. Periodontal infections are the result of an interaction between tooth associated microbial biofilms and the host defences. Periodontal pathogens can affect local and systemic immune and inflammatory responses. The aim of the present study was to evaluate serum C-Reactive Protein (CRP), plasma fibrinogen and peripheral blood levels in healthy subjects, chronic and aggressive periodontitis patients. A total of 55 subjects, 27 males and 28 females were selected for the study. Blood samples were taken from healthy controls (n=20) and patients with chronic periodontitis (n=20) and aggressive periodontitis (n=15). The periodontal status of each patient was assessed by recording Oral Hygiene Index-Simplified (OHI-S), Bleeding Index (BI), Probing Pocket Depth (PPD) and Clinical Attachment Level (CAL). The levels of serum CRP were measured using high sensitivity Enzyme Linked Immunosorbent Assay (ELISA) and levels of plasma fibrinogen were measured using Quantitative Immunoturbidimetric assay. Data description was done in the form of mean and standard deviation and analysis of data was done using one way ANOVA (Analysis of Variance) and Students t-test to test the statistical significance between groups. The levels of serum CRP and plasma fibrinogen was increased in patients with chronic and aggressive periodontitis when compared to healthy controls (pperiodontitis and cardiovascular diseases.

  19. High beta plasma operation in a toroidal plasma producing device

    International Nuclear Information System (INIS)

    Clarke, J.F.

    1978-01-01

    A high beta plasma is produced in a plasma producing device of toroidal configuration by ohmic heating and auxiliary heating. The plasma pressure is continuously monitored and used in a control system to program the current in the poloidal field windings. Throughout the heating process, magnetic flux is conserved inside the plasma and the distortion of the flux surfaces drives a current in the plasma. As a consequence, the total current increases and the poloidal field windings are driven with an equal and opposing increasing current. The spatial distribution of the current in the poloidal field windings is determined by the plasma pressure. Plasma equilibrium is maintained thereby, and high temperature, high beta operation results

  20. Fibrinogen-Induced Streptococcus mutans Biofilm Formation and Adherence to Endothelial Cells

    Directory of Open Access Journals (Sweden)

    Telma Blanca Lombardo Bedran

    2013-01-01

    Full Text Available Streptococcus mutans, the predominant bacterial species associated with dental caries, can enter the bloodstream and cause infective endocarditis. The aim of this study was to investigate S. mutans biofilm formation and adherence to endothelial cells induced by human fibrinogen. The putative mechanism by which biofilm formation is induced as well as the impact of fibrinogen on S. mutans resistance to penicillin was also evaluated. Bovine plasma dose dependently induced biofilm formation by S. mutans. Of the various plasma proteins tested, only fibrinogen promoted the formation of biofilm in a dose-dependent manner. Scanning electron microscopy observations revealed the presence of complex aggregates of bacterial cells firmly attached to the polystyrene support. S. mutans in biofilms induced by the presence of fibrinogen was markedly resistant to the bactericidal effect of penicillin. Fibrinogen also significantly increased the adherence of S. mutans to endothelial cells. Neither S. mutans cells nor culture supernatants converted fibrinogen into fibrin. However, fibrinogen is specifically bound to the cell surface of S. mutans and may act as a bridging molecule to mediate biofilm formation. In conclusion, our study identified a new mechanism promoting S. mutans biofilm formation and adherence to endothelial cells which may contribute to infective endocarditis.

  1. Extraction, radiolabeling, and in vivo catabolism of autologous-origin equine fibrinogen and platelets in the healthy and exercise-stressed horse

    International Nuclear Information System (INIS)

    Coyne, C.P.

    1986-01-01

    Three separate techniques were evaluated for the extraction of autologous-origin fibrinogen from whole equine plasma. Rapid extraction of equine fibrinogen with ammonium sulfate-sodium phosphate buffer, in combination with saturated glycine buffer, provided the most practical means of obtaining a protein extract with the highest degree of biological activity and sufficiently high iodine-125 ( 125 I) radiolabeling efficiencies using monochloroiodine reagent (ICI). A technique was developed for the in vitro radiolabeling of equine platelets suspended in plasma. This entailed the use of the isotope, indium-111 ( 111 In), together with the lipophilic ligand, 2-(mercaptopyridine-N-oxide). This labeling technique achieved labeling efficiencies between 75% and 96%, and in vitro aggregability of 111 In-merc radiolabeled platelets was comparable to that of unlabeled cell isolates. In the final phase of the investigation, autologous-origin 125 I-labeled fibrinogen and 111 In-labeled platelets were applied in a series of equine exercise physiology studies. Elimination of these two radiobiologicals was evaluated in the resting and exercise-stressed horse. Results from these investigations revealed no long-term influence of exercise conditioning on the in vivo kinetics of radiolabeled fibrinogen or platelets

  2. High-beta plasma blobs in the morningside plasma sheet

    Directory of Open Access Journals (Sweden)

    G. Haerendel

    1999-12-01

    Full Text Available Equator-S frequently encountered, i.e. on 30% of the orbits between 1 March and 17 April 1998, strong variations of the magnetic field strength of typically 5–15-min duration outside about 9RE during the late-night/early-morning hours. Very high-plasma beta values were found, varying between 1 and 10 or more. Close conjunctions between Equator-S and Geotail revealed the spatial structure of these "plasma blobs" and their lifetime. They are typically 5–10° wide in longitude and have an antisymmetric plasma or magnetic pressure distribution with respect to the equator, while being altogether low-latitude phenomena  (≤ 15°. They drift slowly sunward, exchange plasma across the equator and have a lifetime of at least 15–30 min. While their spatial structure may be due to some sort of mirror instability, little is known about the origin of the high-beta plasma. It is speculated that the morningside boundary layer somewhat further tailward may be the source of this plasma. This would be consistent with the preference of the plasma blobs to occur during quiet conditions, although they are also found during substorm periods. The relation to auroral phenomena in the morningside oval is uncertain. The energy deposition may be mostly too weak to generate a visible signature. However, patchy aurora remains a candidate for more disturbed periods.Key words. Magnetospheric physics (plasma convection; plasma sheet; plasma waves and instabilities

  3. Very high plasma switches. Basic plasma physics and switch technology

    International Nuclear Information System (INIS)

    Doucet, H.J.; Roche, M.; Buzzi, J.M.

    1988-01-01

    A review of some high power switches recently developed for very high power technology is made with a special attention to the aspects of plasma physics involved in the mechanisms, which determine the limits of the possible switching parameters

  4. Turbulence of high-beta plasma

    International Nuclear Information System (INIS)

    Khvesyuk, V.I.; Chirkov, A.Y.

    1999-01-01

    Principals of numerical modelling of turbulence in high-beta plasma (β > 0.1) are discussed. Creation of transport model for axial symmetric nonuniform confining magnetic field is considered. Numerical model of plasma turbulence in FRC is presented. The physical and mathematical models are formulated from nonuniform axial symmetric high-beta plasma. It is shown that influence of waves arise under this plasma conditions lead to chaotic motion of charged particles across magnetic field. (author)

  5. Fibrinogen is not elevated in the cerebrospinal fluid of patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Ehling Rainer

    2011-10-01

    Full Text Available Abstract Background Elevated plasma fibrinogen levels are a well known finding in acute infectious diseases, acute stroke and myocardial infarction. However its role in the cerebrospinal fluid (CSF of acute and chronic central (CNS and peripheral nervous system (PNS diseases is unclear. Findings We analyzed CSF and plasma fibrinogen levels together with routine parameters in patients with multiple sclerosis (MS, acute inflammatory diseases of the CNS (bacterial and viral meningoencephalitis, BM and VM and PNS (Guillain-Barré syndrome; GBS, as well as in non-inflammatory neurological controls (OND in a total of 103 patients. Additionally, MS patients underwent cerebral MRI scans at time of lumbar puncture. CSF and plasma fibrinogen levels were significantly lower in patients with MS and OND patients as compared to patients with BM, VM and GBS. There was a close correlation between fibrinogen levels and albumin quotient (rho = 0.769, p Conclusions Although previous work has shown clear evidence of the involvement of fibrinogen in MS pathogenesis, this is not accompanied by increased fibrinogen in the CSF compartment.

  6. Fibrinogen adsorption on blocked surface of albumin

    DEFF Research Database (Denmark)

    Holmberg, Maria; Hou, Xiaolin

    2011-01-01

    We have investigated the adsorption of albumin and fibrinogen onto PET (polyethylene terephthalate) and glass surfaces and how pre-adsorption of albumin onto these surfaces can affect the adsorption of later added fibrinogen. For materials and devices being exposed to blood, adsorption...... of fibrinogen is often a non-wanted event, since fibrinogen is part of the clotting cascade and unspecific adsorption of fibrinogen can have an influence on the activation of platelets. Albumin is often used as blocking agent for avoiding unspecific protein adsorption onto surfaces in devices designed to handle...... energies, the adsorption of both albumin and fibrinogen has been monitored simultaneously on the same sample. Information about topography and coverage of adsorbed protein layers has been obtained using AFM (Atomic Force Microscopy) analysis in liquid. Our studies show that albumin adsorbs in a multilayer...

  7. High-vacuum plasma pump

    International Nuclear Information System (INIS)

    Dorodnov, A.M.; Minajchev, V.E.; Miroshkin, S.I.

    1980-01-01

    The action of an electric-arc high-vacuum pump intended for evacuating the volumes in which the operation processes are followed by a high gas evolution is considered. The operation of the pump is based on the principle of controlling the getter feed according to the gas load and effect of plasma sorbtion pumping. The pump performances are given. The starting pressure is about 5 Pa, the limiting residual pressure is about 5x10 -6 Pa, the pumping out rate of nitrogen in the pressure range 5x10 -5 -5x10 -3 Pa accounts for about 4000 l/s, the power consumption comes to 6 kW. Analyzing the results of the test operation of the pump, it has been concluded that its principal advantages are the high starting pressure, controlled getter feed rate and possibility of pumping out the gases which are usually pumped out with difficulty. The operation reliability of the pump is defined mainly by reliable operation of the ignition system of the vacuum arc [ru

  8. High-beta plasma blobs in the morningside plasma sheet

    Directory of Open Access Journals (Sweden)

    G. Haerendel

    Full Text Available Equator-S frequently encountered, i.e. on 30% of the orbits between 1 March and 17 April 1998, strong variations of the magnetic field strength of typically 5–15-min duration outside about 9RE during the late-night/early-morning hours. Very high-plasma beta values were found, varying between 1 and 10 or more. Close conjunctions between Equator-S and Geotail revealed the spatial structure of these "plasma blobs" and their lifetime. They are typically 5–10° wide in longitude and have an antisymmetric plasma or magnetic pressure distribution with respect to the equator, while being altogether low-latitude phenomena 
    (≤ 15°. They drift slowly sunward, exchange plasma across the equator and have a lifetime of at least 15–30 min. While their spatial structure may be due to some sort of mirror instability, little is known about the origin of the high-beta plasma. It is speculated that the morningside boundary layer somewhat further tailward may be the source of this plasma. This would be consistent with the preference of the plasma blobs to occur during quiet conditions, although they are also found during substorm periods. The relation to auroral phenomena in the morningside oval is uncertain. The energy deposition may be mostly too weak to generate a visible signature. However, patchy aurora remains a candidate for more disturbed periods.

    Key words. Magnetospheric physics (plasma convection; plasma sheet; plasma waves and instabilities

  9. Atomic processes in high temperature plasmas

    International Nuclear Information System (INIS)

    Hahn, Y.

    1990-03-01

    Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work

  10. Pre-delivery fibrinogen predicts adverse maternal or neonatal outcomes in patients with placental abruption.

    Science.gov (United States)

    Wang, Liangcheng; Matsunaga, Shigetaka; Mikami, Yukiko; Takai, Yasushi; Terui, Katsuo; Seki, Hiroyuki

    2016-07-01

    Placental abruption is a severe obstetric complication of pregnancy that can cause disseminated intravascular coagulation and progress to massive post-partum hemorrhage. Coagulation disorder due to extreme consumption of fibrinogen is considered the main pathogenesis of disseminated intravascular coagulation in patients with placental abruption. The present study sought to determine if the pre-delivery fibrinogen level could predict adverse maternal or neonatal outcomes in patients with placental abruption. This retrospective medical chart review was conducted in a center for maternal, fetal, and neonatal medicine in Japan with 61 patients with placental abruption. Fibrinogen levels prior to delivery were collected and evaluated for the prediction of maternal and neonatal outcomes. The main outcome measures for maternal outcomes were disseminated intravascular coagulation and hemorrhage, and the main outcome measures for neonatal outcomes were Apgar score at 5 min, umbilical artery pH, and stillbirth. The receiver-operator curve and multivariate logistic regression analyses indicated that fibrinogen significantly predicted overt disseminated intravascular coagulation and the requirement of ≥6 red blood cell units, ≥10 fresh frozen plasma units, and ≥20 fresh frozen plasma units for transfusion. Moderate hemorrhage occurred in 71.5% of patients with a decrease in fibrinogen levels to 155 mg/dL. Fibrinogen could also predict neonatal outcomes. Umbilical artery pH neonatal outcomes with placental abruption. © 2016 Japan Society of Obstetrics and Gynecology. © 2016 Japan Society of Obstetrics and Gynecology.

  11. Changes in fibrin D-dimer, fibrinogen, and protein S during pregnancy

    DEFF Research Database (Denmark)

    Hansen, Anette Tarp; Andreasen, Birgitte Horst; Salvig, Jannie Dalby

    2010-01-01

    Background. Pregnancy is a hypercoagulable state with a 5- to 10- fold higher risk of venous thromboembolism. Existing reference intervals for fibrin D-dimer (D-dimer), functional fibrinogen (fibrinogen) and protein S, free antigen (protein S) are based on non-pregnant patients and reference...... intervals for pregnant patients are warranted. Objectives. The aim of the present study was to contribute to the establishment of reference intervals for D-dimer, fibrinogen and protein S during pregnancy and to discuss the use of the analyses during pregnancy. Methods. We included 55 healthy pregnant women...... in gestational week 11–17, with normal current pregnancy. Blood samples were collected in gestational weeks 11–17, 21–27 and 34–37. The three plasma parameters D-dimer, fibrinogen and protein S were analysed by STA-R Evolution®. Results. A significant rise in D-dimer was found from first to second trimester (p...

  12. Plasma Diagnostics in High Density Reactors

    International Nuclear Information System (INIS)

    Daltrini, A. M.; Moshkalyov, S.; Monteiro, M. J. R.; Machida, M.; Kostryukov, A.; Besseler, E.; Biasotto, C.; Diniz, J. A.

    2006-01-01

    Langmuir electric probes and optical emission spectroscopy diagnostics were developed for applications in high density plasmas. These diagnostics were employed in two plasma sources: an electron cyclotron resonance (ECR) plasma and an RF driven inductively coupled plasma (ICP) plasma. Langmuir probes were tested using a number of probing dimensions, probe tip materials, circuits for probe bias and filters. Then, the results were compared with the optical spectroscopy measurements. With these diagnostics, analyses of various plasma processes were performed in both reactors. For example, it has been shown that species like NH radicals generated in gas phase can have critical impact on films deposited by ECR plasmas. In the ICP source, plasmas in atomic and molecular gases were shown to have different spatial distributions, likely due to nonlocal electron heating. The low-to-high density transitions in the ICP plasma were also studied. The role of metastables is shown to be significant in Ar plasmas, in contrast to plasmas with additions of molecular gases

  13. Fibrinogen adsorption on blocked surface of albumin.

    Science.gov (United States)

    Holmberg, Maria; Hou, Xiaolin

    2011-05-01

    We have investigated the adsorption of albumin and fibrinogen onto PET (polyethylene terephthalate) and glass surfaces and how pre-adsorption of albumin onto these surfaces can affect the adsorption of later added fibrinogen. For materials and devices being exposed to blood, adsorption of fibrinogen is often a non-wanted event, since fibrinogen is part of the clotting cascade and unspecific adsorption of fibrinogen can have an influence on the activation of platelets. Albumin is often used as blocking agent for avoiding unspecific protein adsorption onto surfaces in devices designed to handle biological samples, including protein solutions. It is based on the assumption that proteins adsorbs as a monolayer on surfaces and that proteins do not adsorb on top of each other. By labelling albumin and fibrinogen with two different radioactive iodine isotopes that emit gamma radiation with different energies, the adsorption of both albumin and fibrinogen has been monitored simultaneously on the same sample. Information about topography and coverage of adsorbed protein layers has been obtained using AFM (Atomic Force Microscopy) analysis in liquid. Our studies show that albumin adsorbs in a multilayer fashion on PET and that fibrinogen adsorbs on top of albumin when albumin is pre-adsorbed on the surfaces. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. New aspects of high energy density plasma

    International Nuclear Information System (INIS)

    Hotta, Eiki

    2005-10-01

    The papers presented at the symposium on 'New aspects of high energy density plasma' held at National Institute for Fusion Science are collected in this proceedings. The papers reflect the present status and recent progress in the experiments and theoretical works on high energy density plasma produced by pulsed power technology. The 13 of the presented papers are indexed individually. (J.P.N.)

  15. Lipid profile and levels of homocysteine, leptin, fibrinogen and C-reactive protein in hyperthyroid patients before and after treatment

    Directory of Open Access Journals (Sweden)

    Emine Sütken

    2010-03-01

    Full Text Available Objectives: The present study was carried out to determine whether thyroid hormones affect lipid profile and levels of erithrocyte sedimentation rate (ESR, serum total homocysteine (t-hcy, leptin, fibrinogen, C-reactive protein (CRP in patients with hyperthyroidism.Materials and methods: This study was carried out on 23 hyperthroid subjects (3 men / 20 women, mean age 41.8 ± 2.4 years. Serum levels of homocysteine, leptin, fibrinogen, CRP, total cholesterol (TC, high-density lipoprotein cholesterol (HDL-C, low-density lipoprotein cholesterol (LDL-C and ESR were measured and body mass index (BMI were calculated before and after treatment of hyperthyroidism.Results: Pretreatment t-hcy, TC, LDL-C, HDL-C levels and BMI of patients were significantly lower than those of the post-treatment (p<0.001, for each variable. However, fibrinogen and ESR decreased after the treatment (p<0.001 and p<0.05, respectively. There were no differences in leptin and CRP levels between pre- and post-treatment periods. Pre and post treatment TC and LDL-C levels were negatively correlated with free triiodothyronine (fT3 levels (r=-0.588, p<0.01; r=-0.534, p<0.01; r=-0.543, p<0.01 and r =-0.653, p<0.01, respectively. Pre-treatment HDL-C was inversely correlated with TSH (r=-0.423, p<0.05. Pre-post- treatment LDL-C was negatively correlated with free thyroxine (fT4 levels (r=-0.536, p<0.001 and r=- 0.422, p<0.05 respectively. Pre-treatment TC was inversely correlated with fT4 (r=-0.590, p<0.01.Conclusion: Hyperthyroidism is associated with high plasma fibrinogen and ESR levels. Elevated plasma fibrinogen and ESR levels may be a possible explanation for the high cardiovascular morbidity among hyperthyroidic subjects. These changes may reflect low-grade inflammation or disturbances in coagulation in hyperthyroidism.

  16. Thrombus scintigraphy with Ga-67 DFO-DAS-Fibrinogen, 2

    International Nuclear Information System (INIS)

    Kawasaki, Yukiko

    1987-01-01

    In our previous in vivo study 67 Ga DFO-DAS-Fibrinogen was assessed for its usefulness as a radiopharmaceutical for the detection of thrombin in experimental animals (Report 1). The present study was undertaken to appraise the diagnostic value of 67 Ga DFO-DAS-Fibrinogen in human disease, especially in relation to blood coagulability as well as to thrombolytic drug regimen being given, in an effort to investigate its clinical applicability. Involved in this study were 48 patients with thrombosis proven by X-ray CT and other examinations. Of these 48, 42 had arterial thrombosis (20 with aortic aneurysm including the dissecting form, 11 in postoperative condition following vascular surgery with a prosthesis, 9 with intracardiac thrombosis accompanying heart disease, and 1 each with occlusive arteriosclerosis and cerebral infarction) and 6 had venous thrombosis. The 67 Ga DFO-DAS-Fibrinogen test proved to be positive in 55 % of arterial thrombin and in 50 % of venous thrombin. It is interesting to note that as high a positivity rate as 80 % was obtained for aortic aneurysm, although the positivity rate was disappointingly low for left atrial thrombin. No distinct correlation was noted to exist between the degree of accumulation of the tracer in thrombotic lesions and any of factors conceivably of clinical releavance, i.e. time elapsing from onset till testing, thrombolytic medication being given, and hematological factors. 67 Ga DFO-DAS-Fibrinogen appeared to be a radiodiagnostic agent that could possibly indicate the existing activity status of thrombosis. (author)

  17. Dense high-temperature plasma transport processes

    International Nuclear Information System (INIS)

    Giniyatova, Sh.G.

    2002-01-01

    In this work the transport processes in dense high-temperature semiclassical plasma are studied on the base of the kinetic equation, where the semiclassical potential was used, in its collision integral. The coefficient of plasma electrical conductivity, viscosity and thermal conductivity were received. There were compared with the other authors' results. The Grad's method was used obtaining of viscosity and thermal coefficients. (author)

  18. Tumor response and survival in patients with advanced non-small-cell lung cancer: the predictive value of chemotherapy-induced changes in fibrinogen

    International Nuclear Information System (INIS)

    Zhao, Jun; Zheng, Shuang; Zhou, Qiyin; Li, Heming; Liu, Yunpeng; Qu, Xiujuan; Zhao, Mingfang; Jin, Bo; Yu, Ping; Hu, Xuejun; Teng, Yuee; Zhang, Jingdong; Luo, Ying; Zhang, Lingyun

    2012-01-01

    Hyperfibrinogenemia is a common problem associated with various carcinomas, and is accompanied by hypercoagulablity. In advanced non-small-cell lung cancer (NSCLC) it remains unclear whether or not chemotherapy-induced changes in fibrinogen level relate to chemotherapeutic response and prognosis. The purposes of this study were to: 1) analyze the association between chemotherapy-induced changes in plasma fibrinogen level and the chemotherapeutic response after the first two courses of standard first-line platinum-based chemotherapy; and 2) evaluate the prognostic significance of the basal plasma fibrinogen level in patients with advanced NSCLC. In this retrospective study, the data from 160 patients with advanced NSCLC were collected. The association between the changes in fibrinogen and the response to chemotherapy, or between the pre-and post-chemotherapy fibrinogen levels and patient clinical characteristics, were analyzed using SPSS software. In addition, the prognostic value of pre-chemotherapy fibrinogen levels was assessed. The median pre-chemotherapy plasma fibrinogen level was 4.4 g/L. Pre-chemotherapy plasma fibrinogen levels correlated significantly with gender (p = 0.041). Post-chemotherapy plasma fibrinogen levels correlated with gender (p = 0.023), age (p = 0.018), ECOG (p = 0.002) and tumor response (p = 0.049). Plasma fibrinogen levels markedly decreased after chemotherapy in 98 (61.25 %) patients with pre-chemotherapy hyperfibrinogenemia (p = 0.008); and in this population there was a significant link between the decrease in fibrinogen level, and initial partial response (PR; p = 0.017) and stable disease (SD; p = 0.031). Univariate and multivariate analysis revealed that higher levels of fibrinogen (≥4.4 g/L) and ECOG 1 were positively associated with shorter overall survival (OS). CEA and CA125 also decreased significantly (p =0.015, p =0.000) in DCR group after chemotherapy. This study showed that the reduction in plasma fibrinogen levels

  19. The Primary Role of Fibrinogen-Related Proteins in Invertebrates Is Defense, Not Coagulation

    Science.gov (United States)

    Hanington, Patrick C.; Zhang, Si-Ming

    2010-01-01

    In vertebrates, the conversion of fibrinogen into fibrin is an essential process that underlies the establishment of the supporting protein framework required for coagulation. In invertebrates, fibrinogen-domain-containing proteins play a role in the defense response generated against pathogens; however, they do not function in coagulation, suggesting that this role has been recently acquired. Molecules containing fibrinogen motifs have been identified in numerous invertebrate organisms, and most of these molecules known to date have been linked to defense. Moreover, recent genome projects of invertebrate animals have revealed surprisingly high numbers of fibrinogen-like loci in their genomes, suggesting important and perhaps diverse functions of fibrinogen-like proteins in invertebrates. The ancestral role of molecules containing fibrinogen-related domains (FReDs) with immunity is the focus of this review, with emphasis on specific FReDs called fibrinogen-related proteins (FREPs) identified from the schistosome-transmitting mollusc Biomphalaria glabrata. Herein, we outline the range of invertebrate organisms FREPs can be found in, and detail the roles these molecules play in defense and protection against infection. PMID:21063081

  20. Deposition of fibrinogen on the surface of in vitro thrombi prevents platelet adhesion.

    Science.gov (United States)

    Owaynat, Hadil; Yermolenko, Ivan S; Turaga, Ramya; Lishko, Valeryi K; Sheller, Michael R; Ugarova, Tatiana P

    2015-12-01

    The initial accumulation of platelets after vessel injury is followed by thrombin-mediated generation of fibrin which is deposited around the plug. While numerous in vitro studies have shown that fibrin is highly adhesive for platelets, the surface of experimental thrombi in vivo contains very few platelets suggesting the existence of natural anti-adhesive mechanisms protecting stabilized thrombi from platelet accumulation and continuous thrombus propagation. We previously showed that adsorption of fibrinogen on pure fibrin clots results in the formation of a nonadhesive matrix, highlighting a possible role of this process in surface-mediated control of thrombus growth. However, the deposition of fibrinogen on the surface of blood clots has not been examined. In this study, we investigated the presence of intact fibrinogen on the surface of fibrin-rich thrombi generated from flowing blood and determined whether deposited fibrinogen is nonadhesive for platelets. Stabilized fibrin-rich thrombi were generated using a flow chamber and the time that platelets spend on the surface of thrombi was determined by video recording. The presence of fibrinogen and fibrin on the surface of thrombi was analyzed by confocal microscopy using specific antibodies. Examination of the spatial distribution of two proteins revealed the presence of intact fibrinogen on the surface of stabilized thrombi. By manipulating the surface of thrombi to display either fibrin or intact fibrinogen, we found that platelets adhere to fibrin- but not to fibrinogen-coated thrombi. These results indicate that the fibrinogen matrix assembled on the outer layer of stabilized in vitro thrombi protects them from platelet adhesion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Competitions between fibrinogen with its degradation products for interactions with the platelet-fibrinogen receptor

    International Nuclear Information System (INIS)

    Thorsen, L.I.; Brosstad, F.; Gogstad, G.; Sletten, K.; Solum, N.O.

    1986-01-01

    Direct binding of 125 -I-labelled plasmic and CNBr-derived fibrin (ogen) fragments (pre-X, X, Y, D, Degta, Efg, E1, N-DSK, N-dsk) to gel-filtered platelets was compared to their ability to support or inhibit ADP-induced aggregation, and to compete with fibrinogen for binding to ADP-stimulated platelets. Pre-X was the only fragment that supported aggregation. All fragments tested except for E derived from fibrinogen (Efg) and Degta bound specifically to the platelets and inhibited ADP-induced aggregation in the presence of fibrinogen. Competitive binding studies with fibrinogen and fragments labelled with different isotopes of iodine, or inhibition of binding of labelled fibrinogen with unlabelled fragments showed that all of the fragments except Efg and Degta were able to compete with fibrinogen for binding. When simultaneous binding of N-dsk and fibrinogen was studied, an increased binding of both ligands was observed probably due to complex formation. The results fully agree with previous findings of binding to immunoprecipitated glycoprotein IIb-IIIa after crossed immunoelectrophoresis. We conclude that the fibrinogen molecule contains at least six sequences responsible for platelet interaction, two in the E domain and two in each of the C-terminal parts of the fibrinogen molecule

  2. Incorporation of vitronectin into fibrin clots. Evidence for a binding interaction between vitronectin and gamma A/gamma' fibrinogen.

    Science.gov (United States)

    Podor, Thomas J; Campbell, Stephanie; Chindemi, Paul; Foulon, Denise M; Farrell, David H; Walton, Philip D; Weitz, Jeffrey I; Peterson, Cynthia B

    2002-03-01

    Vitronectin is an abundant plasma protein that regulates coagulation, fibrinolysis, complement activation, and cell adhesion. Recently, we demonstrated that plasma vitronectin inhibits fibrinolysis by mediating the interaction of type 1 plasminogen activator inhibitor with fibrin (Podor, T. J., Peterson, C. B., Lawrence, D. A., Stefansson, S., Shaughnessy, S. G., Foulon, D. M., Butcher, M., and Weitz, J. I. (2000) J. Biol. Chem. 275, 19788-19794). The current studies were undertaken to further examine the interactions between vitronectin and fibrin(ogen). Comparison of vitronectin levels in plasma with those in serum indicates that approximately 20% of plasma vitronectin is incorporated into the clot. When the time course of biotinylated-vitronectin incorporation into clots formed from (125)I-fibrinogen is monitored, vitronectin incorporation into the clot parallels that of fibrinogen in the absence or presence of activated factor XIII. Vitronectin binds specifically to fibrin matrices with an estimated K(d) of approximately 0.6 microm. Additional vitronectin subunits are assembled on fibrin-bound vitronectin multimers through self-association. Confocal microscopy of fibrin clots reveals the globular vitronectin aggregates anchored at intervals along the fibrin fibrils. This periodicity raised the possibility that vitronectin interacts with the gamma A/gamma' variant of fibrin(ogen) that represents about 10% of total fibrinogen. In support of this concept, the vitronectin which contaminates fibrinogen preparations co-purifies with the gamma A/gamma' fibrinogen fraction, and clots formed from gamma A/gamma' fibrinogen preferentially bind vitronectin. These studies reveal that vitronectin associates with fibrin during coagulation, and may thereby modulate hemostasis and inflammation.

  3. Internal modes in high-temperature plasmas

    International Nuclear Information System (INIS)

    Crew, G.B.

    1983-02-01

    The linear stability of current-carrying toroidal plamsas is examined to determine the possibility of exciting global internal modes. The ideal magnetohydrodynamic (MHD) theory provides a useful framework for the analysis of these modes, which involve a kinking of the central portion of the plasma column. Non-ideal effects can also be important, and these are treated for high-temperature regimes where the plasma is collisionless

  4. Construction of a high beta plasma source

    International Nuclear Information System (INIS)

    Naraghi, M.; Torabi-Fard, A.

    1976-02-01

    A high beta plasma source has been designed and constructed. This source will serve as a means of developing and exercising different diagnostic techniques as required for ALVAND I, linear theta pinch experiment. Also, it will serve to acquaint the technicians with some of the techniques and safety rules of high voltage and capacitor discharge experiments. The operating parameters of the theta pinch and Z-pinch preionization is presented and the program of diagnostic measurements on the high beta plasma source is discussed

  5. Experimental study of high beta toroidal plasmas

    International Nuclear Information System (INIS)

    Kellman, A.G.

    1983-09-01

    Experiments on the Wisconsin Levitated Toroidal Octupole have produced a wide range of stable high β plasmas with β significantly above single fluid MHD theory predictions. A stable β approx. 8% plasma, twice the fluid limit, is obtained with 5 rho/sub i/ approx. L/sub n/ and tau/sub β/ approx. = 6000 tau/sub Alfven/ = 600 μsec. The enhanced stability is explained with a kinetic treatment that includes the effect of finite ion gyroradius which couples the ballooning mode to an ion drift wave. In a more collisional, large gyroradius (2 rho/sub i/ approx. L/sub n/) regime, a stable β approx. 35% plasma is obtained with a decay time of 1000 Alfven times. Measurement of the equilibrium magnetic field in this regime indicates that the diamagnetic current density is five times smaller than predicted by ideal MHD, probably due to ion gyroviscosity. Particle transport is anomalous and ranges from agreement with the classical diffusion rate at the highest beta, lowest field plasma (B/sub P/ = 200 G), to thirteen times the classical rate in a β=11%, high field plasma (B/sub P/ = 860 G) where the level of enhancement increase with magnetic field. Fluctuations in density, electrostatic potential, and magnetic field have been studied in plasmas with β from 0.1% to 40%

  6. Polymorphism in beta fibrinogen -455 g/a gene was associated with diabetic in severe ischemic stroke patients

    Science.gov (United States)

    Ritarwan, Kiking; Kadri, Alfansuri; Juwita Sembiring, Rosita

    2018-03-01

    There is a association of polymorphism in the promoter region of the beta fibrinogen gene -455 G/A with enhancement plasma fibrinogen level. Diabetes mellitus is a risk factor for early neurologic deterioration in acute ischemic stroke. The prothrombotic fibrinogen protein is frequently elevated in patients with diabetes and may be association with poorer prognosis. This study evaluated the association of beta fibrinogen gene -455 G/A promoter polymorphism on modified Ranking Scale of Ischemic Stroke patients treated with diabetic and nondiabetic group. In a Cohort study design comprises 200 consecutive patients diabetic and a nondiabetic who, three months using completed a detailed outcome stroke. Of 200 samples genotype distribution were 27.1% for GG+GA and 0% for AA with diabetic and than 4.4% for GG+GA and 0.05% diabetic patients. Fibrinogen levels were higher in diabetic than nondiabetic group patients (307.7 + 106.3 vs 278 + 84 gr/dl, p=0.002). Fibrinogen level was found to be an independent predictor for diabetic patients. On Genotype GG+GA were associated wth diabetic and nondiabetic group patients. Modified Rankin Scale on day 90 were found associated with diabetic and nondiabetic patients. Conclusion: Elevated fibrinogen level is dose-dependently associated with 90 days outcome severity stroke with diabetic following ischemic stroke

  7. Quantum Phenomena in High Energy Density Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Murnane, Margaret [Univ. of Colorado, Boulder, CO (United States); Kapteyn, Henry [Univ. of Colorado, Boulder, CO (United States)

    2017-05-10

    The possibility of implementing efficient (phase matched) HHG upconversion of deep- UV lasers in multiply-ionized plasmas, with potentially unprecedented conversion efficiency is a fascinating prospect. HHG results from the extreme nonlinear response of matter to intense laser light:high harmonics are radiated as a result of a quantum coherent electron recollision process that occurs during laser field ionization of an atom. Under current support from this grant in work published in Science in 2015, we discovered a new regime of bright HHG in highly-ionized plasmas driven by intense UV lasers, that generates bright harmonics to photon energies >280eV

  8. Beyond genetic factors in familial amyloidotic polyneuropathy: protein glycation and the loss of fibrinogen's chaperone activity.

    Directory of Open Access Journals (Sweden)

    Gonçalo da Costa

    Full Text Available Familial amyloidotic polyneuropathy (FAP is a systemic conformational disease characterized by extracellular amyloid fibril formation from plasma transthyretin (TTR. This is a crippling, fatal disease for which liver transplantation is the only effective therapy. More than 80 TTR point mutations are associated with amyloidotic diseases and the most widely accepted disease model relates TTR tetramer instability with TTR point mutations. However, this model fails to explain two observations. First, native TTR also forms amyloid in systemic senile amyloidosis, a geriatric disease. Second, age at disease onset varies by decades for patients bearing the same mutation and some mutation carrier individuals are asymptomatic throughout their lives. Hence, mutations only accelerate the process and non-genetic factors must play a key role in the molecular mechanisms of disease. One of these factors is protein glycation, previously associated with conformational diseases like Alzheimer's and Parkinson's. The glycation hypothesis in FAP is supported by our previous discovery of methylglyoxal-derived glycation of amyloid fibrils in FAP patients. Here we show that plasma proteins are differentially glycated by methylglyoxal in FAP patients and that fibrinogen is the main glycation target. Moreover, we also found that fibrinogen interacts with TTR in plasma. Fibrinogen has chaperone activity which is compromised upon glycation by methylglyoxal. Hence, we propose that methylglyoxal glycation hampers the chaperone activity of fibrinogen, rendering TTR more prone to aggregation, amyloid formation and ultimately, disease.

  9. High-frequency conductivity of photoionized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Anakhov, M. V.; Uryupin, S. A., E-mail: uryupin@sci.lebedev.ru [National Research Nuclear University “MEPhI,” (Russian Federation)

    2016-08-15

    The tensor of the high-frequency conductivity of a plasma created via tunnel ionization of atoms in the field of linearly or circularly polarized radiation is derived. It is shown that the real part of the conductivity tensor is highly anisotropic. In the case of a toroidal velocity distribution of photoelectrons, the possibility of amplification of a weak high-frequency field polarized at a sufficiently large angle to the anisotropy axis of the initial nonequilibrium distribution is revealed.

  10. High-Latitude Space Plasma Physics

    International Nuclear Information System (INIS)

    Hultqvist, B.; Hagfors, T.

    1983-01-01

    This book constitutes the proceedings of the Nobel Symposium No. 54 on High Latitude Magnetospheric/Ionospheric Plasma Physics. The main purpose of the symposium was to prepare for the European research effort in space plasma physics in the mid-1980's, in which two major constituents are the European Incoherent Scatter Association (EISCAT) facilities and the Swedish satellite Viking. The physics of the high-latitude ionosphere and how this part of near space is affected by the properties of the solar wind and the interplanetary magnetic field are explored. A detailed discussion is provided on high-latitude magnetospheric physics at altitudes of 1-2 earth radii, the main focus of the Viking project. Specific topics considered include the role of the auroral ionosphere in magnetospheric substorms, the low altitude cleft, ionospheric modification and stimulated emissions, plasma physics on auroral field lines, solar wind-magnetosphere energy coupling, cold plasma distribution above a few thousand kilometers at high latitudes, hot electrons in and above the auroral ionosphere, the correlation of auroral kilometric radiation with visual auroras and with Birkeland currents, electrostatic waves in the topside ionosphere, solitary waves and double layers, and an Alfven wave model of auroral arcs

  11. Theory of high temperature plasmas. Final report

    International Nuclear Information System (INIS)

    Davidson, R.C.; Liu, C.S.

    1977-01-01

    This is a report on the technical progress in our analytic studies of high-temperature fusion plasmas. We also emphasize that the research summarized here makes extensive use of computational methods and therefore forms a strong interface with our numerical modeling program which is discussed later in the report

  12. Clotting of mammalian fibrinogens by papain: a re-examination.

    Science.gov (United States)

    Doolittle, Russell F

    2014-10-28

    Papain has long been known to cause the gelation of mammalian fibrinogens. It has also been reported that papain-fibrin is insoluble in dispersing solvents like strong urea or sodium bromide solutions, similar to what is observed with thrombin-generated clots in the presence of factor XIIIa and calcium. In those old studies, both the gelation and subsequent clot stabilization were attributed to papain, although the possibility that the second step might be due to contaminating factor XIII in fibrinogen preparations was considered. I have revisited this problem in light of knowledge acquired over the past half-century about thiol proteases like papain, which mostly cleave peptide bonds, and transglutaminases like factor XIIIa that catalyze the formation of ε-lysyl-γ-glutamyl cross-links. Recombinant fibrinogen, inherently free of factor XIII and other plasma proteins, formed a stable gel when treated with papain alone. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis revealed that the intermolecular cross-linking in papain-fibrin leads to γ-chain dimers, trimers, and tetramers, just as is the case with thrombin-factor XIIIa-stabilized fibrin. Mass spectrometry of bands excised from gels showed that the cross-linked material is quite different from what occurs with factor XIIIa, however. With papain, the cross-linking occurs between γ chains in neighboring protofibrils becoming covalently linked in a "head-to-tail" fashion by a transpeptidation reaction involving the α-amino group of γ-Tyr1 and a papain cleavage site at γ-Gly403 near the carboxy terminus, rather than by the (reciprocal) "tail-to-tail" manner that occurs with factor XIIIa and that depends on cross-links between γ-Lys406 and γ-Gln398.

  13. Two novel fibrinogen variants in the C-terminus of the B.beta.-chain: fibrinogen Rokycany and fibrinogen Znojmo

    Czech Academy of Sciences Publication Activity Database

    Kotlín, R.; Reicheltová, Z.; Suttnar, J.; Salaj, P.; Hrachovinová, I.; Riedel, Tomáš; Malý, M.; Oravec, M.; Kvasnička, J.; Dyr, J. E.

    2010-01-01

    Roč. 30, č. 3 (2010), s. 311-318 ISSN 0929-5305 R&D Projects: GA AV ČR KAN200670701 Institutional research plan: CEZ:AV0Z40500505 Keywords : fibrinogen * missense mutation * hypofibrinogenemia Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.539, year: 2010

  14. High beta plasmas in the PBX tokamak

    International Nuclear Information System (INIS)

    Bol, K.; Buchenauer, D.; Chance, M.

    1986-04-01

    Bean-shaped configurations favorable for high β discharges have been investigated in the Princeton Beta Experiment (PBX) tokamak. Strongly indented bean-shaped plasmas have been successfully formed, and beta values of over 5% have been obtained with 5 MW of injected neutral beam power. These high beta discharges still lie in the first stability regime for ballooning modes, and MHD stability analysis implicates the external kink as responsible for the present β limit

  15. Transport in JET high performance plasmas

    International Nuclear Information System (INIS)

    2001-01-01

    Two type of high performance scenarios have been produced in JET during DTE1 campaign. One of them is the well known and extensively used in the past ELM-free hot ion H-mode scenario which has two distinct regions- plasma core and the edge transport barrier. The results obtained during DTE-1 campaign with D, DT and pure T plasmas confirms our previous conclusion that the core transport scales as a gyroBohm in the inner half of plasma volume, recovers its Bohm nature closer to the separatrix and behaves as ion neoclassical in the transport barrier. Measurements on the top of the barrier suggest that the width of the barrier is dependent upon isotope and moreover suggest that fast ions play a key role. The other high performance scenario is a relatively recently developed Optimised Shear Scenario with small or slightly negative magnetic shear in plasma core. Different mechanisms of Internal Transport Barrier (ITB) formation have been tested by predictive modelling and the results are compared with experimentally observed phenomena. The experimentally observed non-penetration of the heavy impurities through the strong ITB which contradicts to a prediction of the conventional neo-classical theory is discussed. (author)

  16. Transport in JET high performance plasmas

    International Nuclear Information System (INIS)

    1999-01-01

    Two type of high performance scenarios have been produced in JET during DTE1 campaign. One of them is the well known and extensively used in the past ELM-free hot ion H-mode scenario which has two distinct regions- plasma core and the edge transport barrier. The results obtained during DTE-1 campaign with D, DT and pure T plasmas confirms our previous conclusion that the core transport scales as a gyroBohm in the inner half of plasma volume, recovers its Bohm nature closer to the separatrix and behaves as ion neoclassical in the transport barrier. Measurements on the top of the barrier suggest that the width of the barrier is dependent upon isotope and moreover suggest that fast ions play a key role. The other high performance scenario is a relatively recently developed Optimised Shear Scenario with small or slightly negative magnetic shear in plasma core. Different mechanisms of Internal Transport Barrier (ITB) formation have been tested by predictive modelling and the results are compared with experimentally observed phenomena. The experimentally observed non-penetration of the heavy impurities through the strong ITB which contradicts to a prediction of the conventional neo-classical theory is discussed. (author)

  17. The compact mirrors with high pressure plasmas

    International Nuclear Information System (INIS)

    Anikeev, A.V.; Bagryansky, P.A.; Ivanov, A.A.; Lizunov, A.A.; Murakhtin, S.V.; Prikhodko, V.V.; Collatz, S.; Noack, K.

    2004-01-01

    The gas dynamic trap (GDP) experimental facility at the Budker Institute Novosibirsk is a long axial-symmetric mirror system with a high mirror ratio variable in the range of 12.5 - 100 for the confinement of a two-component plasma. One component is a collisional plasma with ion and electron temperatures up to 100 eV and density up to 10 14 cm -3 . The second component is the population of high-energetic fast ions with energies of 2-18 keV and a density up to 10 13 cm -3 which is produced by neutral beam injection (NBI). GDP is currently undergoing an upgrade whose first stage is the achievement of the synthesized hot ion plasmoid experiment (SHIP). This experiment aims at the investigation of plasmas and at the knowledge of plasma parameters that have never been achieved before in magnetic mirrors. The paper presents the physical concept of the SHIP experiment, the results of numerical pre-calculations and draws conclusions regarding possible scenarios of experiments. The simulation of a maximal NBI power regime with hydrogen injection gave a fast ion density of 1.2*10 14 cm -3 with a mean energy of 14 keV. The calculation of the deuterium injection regime with 2 MW NBI power gave a maximal fast ion density of 1.9*10 14 cm -3 with a beam energy of 9 keV. The calculation of an experimental scenario with reduced magnetic field resulted in a maximal β-value of 62%, so this regime is recommended for the study of high-β effects in plasmas confined in axial-symmetric mirrors

  18. Composition comprising radioactive labeled-fibrinogen and albumin

    International Nuclear Information System (INIS)

    Charlton, J.C.; Gravett, D.L.

    1976-01-01

    The stability of fibrinogen is improved by mixing it with albumin, preferably at least 5 parts by weight of albumin per part by weight of fibrinogen. By this invention, iodinated ( 125 I) human fibrinogen can be stabilized with human serum albumin for use in the diagnosis of thrombi

  19. Effects of tibolone on fibrinogen and antithrombin III: A systematic review and meta-analysis of controlled trials.

    Science.gov (United States)

    Bała, Małgorzata; Sahebkar, Amirhossein; Ursoniu, Sorin; Serban, Maria-Corina; Undas, Anetta; Mikhailidis, Dimitri P; Lip, Gregory Y H; Rysz, Jacek; Banach, Maciej

    2017-10-01

    Tibolone is a synthetic steroid with estrogenic, androgenic and progestogenic activity, but the evidence regarding its effects on fibrinogen and antithrombin III (ATIII) has not been conclusive. We assessed the impact of tibolone on fibrinogen and ATIII through a systematic review and meta-analysis of available randomized controlled trials (RCTs). The search included PUBMED, Web of Science, Scopus, and Google Scholar (up to January 31st, 2016) to identify controlled clinical studies investigating the effects of oral tibolone treatment on fibrinogen and ATIII. Overall, the impact of tibolone on plasma fibrinogen concentrations was reported in 10 trials comprising 11 treatment arms. Meta-analysis did not suggest a significant reduction of fibrinogen levels following treatment with tibolone (WMD: -5.38%, 95% CI: -11.92, +1.16, p=0.107). This result was robust in the sensitivity analysis and not influenced after omitting each of the included studies from meta-analysis. When the studies were categorized according to the duration of treatment, there was no effect in the subsets of trials lasting either analysis. There was no differential effect of tibolone on plasma ATIII concentrations in trials with either analysis, meta-regression did not suggest any significant association between the changes in plasma concentrations of fibrinogen (slope: +0.40; 95% CI: -0.39, +1.19; p=0.317) and ATIII (slope: -0.17; 95% CI: -0.54, +0.20; p=0.374) with duration of treatment. In conclusion, meta-analysis did not suggest a significant reduction of fibrinogen and ATIII levels following treatment with tibolone. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. High order harmonic generation from plasma mirror

    International Nuclear Information System (INIS)

    Thaury, C.

    2008-09-01

    When an intense laser beam is focused on a solid target, its surface is rapidly ionized and forms a dense plasma that reflects the incident field. For laser intensities above few 10 15 W/cm 2 , high order harmonics of the laser frequency, associated in the time domain to a train of atto-second pulses (1 as = 10 18 s), can be generated upon this reflection. Because such a plasma mirror can be used with arbitrarily high laser intensities, this process should eventually lead to the production of very intense pulses in the X-ray domain. In this thesis, we demonstrate that for laser intensities about 10 19 W/cm 2 , two mechanisms can contribute to the generation of high order harmonics: the coherent wake emission and the relativistic emission. These two mechanisms are studied both theoretically and experimentally. In particular, we show that, thanks to very different properties, the harmonics generated by these two processes can be unambiguously distinguished experimentally. We then investigate the phase properties of the harmonic, in the spectral and in the spatial domain. Finally, we illustrate how to exploit the coherence of the generation mechanisms to get information on the dynamics of the plasma electrons. (author)

  1. Familial hypofibrinogenaemia associated with heterozygous substitution of a conserved arginine residue; Bbeta255 Arg-->His (Fibrinogen Merivale).

    Science.gov (United States)

    Maghzal, Ghassan J; Brennan, Stephen O; Fellowes, Andrew P; Spearing, Ruth; George, Peter M

    2003-02-21

    Sequencing of all three fibrinogen genes from an individual with hypofibrinogenaemia led to the identification of two new point mutations in the Bbeta gene. Family studies showed the mutations Bbeta255 Arg-->His (Fibrinogen Merivale) and Bbeta148 Lys-->Asn (Fibrinogen Merivale II) were on different alleles and that only the Bbeta255 Arg-->His mutation segregated with hypofibrinogenaemia. Three simple heterozygotes for this mutation had mean fibrinogen concentrations of 1.4 mg/ml, while heterozygotes for the Bbeta148 Lys-->Asn mutation had normal fibrinogen concentrations. ESI MS analysis of endoproteinase Asp-N digests of Bbeta chains showed that the Bbeta255 Arg-->His substitution was not expressed in plasma, confirming it as the cause of the hypofibrinogenaemia. The Bbeta148 Lys-->Asn chains, on the other hand, were equally expressed with wild-type Bbeta chains in simple heterozygotes. Genotype analysis failed to detect either substitution in 182 healthy controls. Arg(255) is located in the first strand of the five-stranded sheet that forms the main feature of the betaD domain and appears to form an essential H bond with Gly(414). Both the Arg and Gly are absolutely conserved, not only in all known Bbeta chains, but also in all homologous alphaE and gamma chains and in all fibrinogen-related proteins. Protein instability from loss of this contact could easily explain the association of this mutation with hypofibrinogenaemia.

  2. High-speed photography application to pulsed hot plasma investigation

    International Nuclear Information System (INIS)

    Borov'etskij, M.; Koz'yarkevich, V.; Skrzhechanovskij, V.; Socha, R.

    1986-01-01

    Plasma focus is investigated using an electron-optical chamber for high-speed photography (KSK-1). Experimental devices for studying dynamics and structure of a plasma layer in the chosen interval, recording plasma spectra with time resolution as well as for studying the dynamics and structure of a plasma layer by Schlieren- and shadow methods are briefly described. Experimental results are presented

  3. Atomic processes in high temperature plasmas

    International Nuclear Information System (INIS)

    Hahn, Y.

    1991-07-01

    This is the final report on the project Atomic Processes in High Temperature Plasmas', which has been completed in June 30, 1991. The original contract started in 1978. The dielectronic recombination (DR) rate coefficients were calculated for ions with the number of electrons N = 1, 2, 3, 4, 5, 10, 11, and 12. The result was then used to construct a new and improved rate formula. Other important resonant processes, which are closely related to DR, were also studied to interpret experiments and to test the DR theory. The plasma field and the density effects on the rate coefficients was found to be important, and a consistent correction procedure is being developed. The available data on the DR rates and their accuracy do not yet fully meet the requirement for plasma modeling; there are serious gaps in the available data, and the currently adopted theoretical procedure needs improvements. Critical assessment of the current status of the DR problem is presented, and possible future work needed is summarized

  4. High order harmonic generation from plasma mirrors

    International Nuclear Information System (INIS)

    George, H.

    2010-01-01

    When an intense laser beam is focused on a solid target, the target's surface is rapidly ionized and forms dense plasma that reflects the incident field. For laser intensities above few 10 to the power of 15 Wcm -2 , high order harmonics of the laser frequency, associated in the time domain to a train of atto-second pulses (1 as 10 -18 s), can be generated upon this reflection. In this thesis, we developed numerical tools to reveal original aspects of harmonic generation mechanisms in three different interaction regime: the coherent wake emission, the relativistic emission and the resonant absorption. In particular, we established the role of these mechanisms when the target is a very thin foil (thickness of the order of 100 nm). Then we study experimentally the spectral, spatial and coherence properties of the emitted light. We illustrate how to exploit these measurements to get information on the plasma mirror dynamics on the femtosecond and atto-second time scales. Last, we propose a technique for the single-shot complete characterization of the temporal structure of the harmonic light emission from the laser-plasma mirror interaction. (author)

  5. Association of β-fibrinogen promoter gene polymorphism (−148C/T), hyperfibrinogenemia and ischemic stroke in young adult patients

    OpenAIRE

    Imran, Imran; Lamsudin, Rusdi; Idjradinata, Ponpon; Achmad, Tri Hanggono; Maskoen, Amelani; Wibowo, Samekto; Harapan, Harapan

    2015-01-01

    Background: Single nucleotide polymorphism (SNP) −148C/T which is located in β-fibrinogen gene (FGB) promoter has correlation with fibrinogen levels; however, the association of SNP −148C/T and ischemic stroke in young adult patients is contradictory. Aim: To determine the association of SNP −148C/T in FGB promoter with plasma fibrinogen levels and ischemic stroke in young adults. Subjects and methods: In this case-control study, SNP −148C/T among 107 ischemic stroke patients and 94 con...

  6. Interaction of fibrinogen and albumin with titanium dioxide nanoparticles of different crystalline phases

    International Nuclear Information System (INIS)

    Marucco, Arianna; Fenoglio, Ivana; Turci, Francesco; Fubini, Bice

    2013-01-01

    TiO 2 nanoparticles (NPs) are contained in different kinds of industrial products including paints, self-cleaning glasses, sunscreens. TiO 2 is also employed in photocatalysis and it has been proposed for waste water treatment. Micrometric TiO 2 is generally considered a safe material, while there is concern on the possible health effects of nanometric titania. Due to their small size NPs may migrate within the human body possibly entering in the blood stream. Therefore studies on the interaction of NPs with plasma proteins are needed. In fact, the interaction with proteins is believed to ultimately influences the NPs biological fate. Fibrinogen and albumin are two of the most abundant plasma proteins. They are involved in several important physiological functions. Furthermore, fibrinogen is known to trigger platelet adhesion and inflammation. For these reasons the study of the interaction between these protein and nanoparticles is an important step toward the understanding of the behavior of NPs in the body. In this study we investigated the interaction of albumin and fibrinogen with TiO 2 nanoparticles of different crystal phases (rutile and anatase) using an integrated set of techniques. The amount of adsorbed fibrinogen and albumin for each TiO 2 surface was investigated by using the bicinchoninic acid assay (BCA). The variation of the surface charge of the NP-protein conjugates respect to the naked NPs was used to indirectly estimate both surface coverage and reversibility of the adsorption upon dilution. Surface charge was monitored by measuring the ζ potential with a conventional electrophoretic light scattering (ELS) system. The extent of protein deformation was evaluated by Raman Spectroscopy. We found that both proteins adsorb irreversibly against electrostatic repulsion, likely undergoing conformational changes or selective orientation upon adsorption. The size of primary particles and the particles aggregation rather than the crystal phase modulate the

  7. High explosive driven plasma opening switches

    International Nuclear Information System (INIS)

    Greene, A.E.; Bowers, R.L.; Brownell, J.H.; Goforth, J.H.; Oliphant, T.A.; Weiss, D.L.

    1983-01-01

    A joint theoretical and experimental effort is underway to understand and improve upon the performance of high explosive driven plasma opening switches such as those first described by Pavlovskii et al. We have modeled these switches in both planar and cylindrical geometry using a one dimensional Lagrangian MHD code. This one-dimensional analysis is now essentially complete. It has shown that simple, one-dimensional, compression of the current-carrying channel can explain the observed resistance increases during the time of flight of the HE detonation products. Our calculations imply that ionization plays an important role as an energy sink and the performance of these switches might be improved by a judicious choice of gases. We also predict improved performance by lowering the pressure in the plasma channel. The bulk of our experimental effort to date has been with planar switches. We have worked with current densities of 0.25 to 0.4 MA/cm and have observed resistance increases of 40 to 60 mΩ. Significant resistance increases are observed later than the time of flight of the HE detonation products. We suggest that these resistance increases are due to mixing between the hot plasma and the relatively cooler detonation products. Such mixing is not included in the 1-D, Lagrangian code. We are presently beginning a computational effort with a 2-D Eulerian code. The status of this effort is discussed. Experimentally we have designed an apparatus that will permit us to test the role of different gases and pressures. This system is also in a planar geometry, but the plasma channel is doughnut shaped, permitting us to avoid edge effects associated with the planar rectangular geometry. The first experiments with this design are quite encouraging and the status of this effort is also discussed

  8. Interferometric measurements of plasma density in highplasmas

    International Nuclear Information System (INIS)

    Quinn, W.E.

    1977-01-01

    The coupled-cavity laser interferometer technique is particularly applicable to the measurement of pulsed plasma densities. This technique is based on the fact that if a small fraction of a gas laser's output radiation is reflected into the laser with an external mirror, the intensity of the laser output is modulated. These amplitude or intensity modulations are produced by changes in the laser gain. A rotating corner mirror or an oscillating mirror can be used to produce a continuous feedback modulation of the interferometer which produces a continuous background fringe pattern. The presence of plasma in the outer cavity causes an additional change which results in a phase shift of the regular period of the background fringe pattern. The integral of the plasma density along the line of sight can be evaluated by comparison of the time history of the fringes obtained with and without plasma

  9. Multichannel euv spectroscopy of high temperature plasmas

    International Nuclear Information System (INIS)

    Fonck, R.J.

    1983-11-01

    Spectroscopy of magnetically confined high temperature plasmas in the visible through x-ray spectral ranges deals primarily with the study of impurity line radiation or continuum radiation. Detailed knowledge of absolute intensities, temporal behavior, and spatial distributions of the emitted radiation is desired. As tokamak facilities become more complex, larger, and less accessible, there has been an increased emphasis on developing new instrumentation to provide such information in a minimum number of discharges. The availability of spatially-imaging detectors for use in the vacuum ultraviolet region (especially the intensified photodiode array) has generated the development of a variety of multichannel spectrometers for applications on tokamak facilities

  10. Device for plasma confinement and heating by high currents and nonclassical plasma transport properties

    Science.gov (United States)

    Coppi, B.; Montgomery, D.B.

    1973-12-11

    A toroidal plasma containment device having means for inducing high total plasma currents and current densities and at the same time emhanced plasma heating, strong magnetic confinement, high energy density containment, magnetic modulation, microwaveinduced heating, and diagnostic accessibility is described. (Official Gazette)

  11. Platelet fibrinogen binding in Basset Hound Hereditary Thrombopathy

    International Nuclear Information System (INIS)

    Patterson, W.; Estry, D.; Schwartz, K.; Bell, T.

    1986-01-01

    Platelets from dogs with Basset Hound Hereditary Thrombopathy (BHT) display a thrombasthenia-like aggregation defect but have been shown to have normal amounts of platelet membrane glycoproteins IIb and IIIa (GP IIb-IIIa). In order to investigate the possibility of a functionally abnormal GPIIb-IIIa complex, which might be unable to bind fibrinogen after stimulation, fibrinogen binding in BHT was evaluated. Two canine fibrinogen preparations were used, one from BHT dogs and one from normal control dogs, as well as a human fibrinogen preparation. Platelets from BHT and normal dogs were activated with 1 x 10 -5 M ADP in the presence of 125 I-labeled fibrinogen and the surface bound radioactivity quantitated. For all fibrinogen preparations, the amount of fibrinogen bound by BHT platelets was not significantly different than that bound by normal dog platelets. BHT platelets bound 23,972 +/- 3612 and normal dog platelets bound 23,033 +/- 3971 molecules of fibrinogen per platelet. The BHT platelet aggregation defect does not seem to be caused by a functionally abnormal GP IIb-IIIa complex, since BHT platelets bind normal amounts of fibrinogen. The results suggest that fibrinogen binding is not sufficient for platelet aggregation, and other factors, perhaps receptor mobility and membrane phospholipid content should be investigated in BHT

  12. A plasma microlens for ultrashort high power lasers

    Science.gov (United States)

    Katzir, Yiftach; Eisenmann, Shmuel; Ferber, Yair; Zigler, Arie; Hubbard, Richard F.

    2009-07-01

    We present a technique for generation of miniature plasma lens system that can be used for focusing and collimating a high intensity femtosecond laser pulse. The plasma lens was created by a nanosecond laser, which ablated a capillary entrance. The spatial configuration of the ablated plasma focused a high intensity femtosecond laser pulse. This configuration offers versatility in the plasma lens small f-number for extremely tight focusing of high power lasers with no damage threshold restrictions of regular optical components.

  13. A plasma microlens for ultrashort high power lasers

    International Nuclear Information System (INIS)

    Katzir, Yiftach; Eisenmann, Shmuel; Ferber, Yair; Zigler, Arie; Hubbard, Richard F.

    2009-01-01

    We present a technique for generation of miniature plasma lens system that can be used for focusing and collimating a high intensity femtosecond laser pulse. The plasma lens was created by a nanosecond laser, which ablated a capillary entrance. The spatial configuration of the ablated plasma focused a high intensity femtosecond laser pulse. This configuration offers versatility in the plasma lens small f-number for extremely tight focusing of high power lasers with no damage threshold restrictions of regular optical components.

  14. Mice plasma fibrinogen consumption by thrombin-like enzyme present in rattlesnake venom from the North-East region of Argentina Consumo de fibrinógeno plasmático en ratones por acción de enzima con actividad trombínica presente en el veneno de cascabel del nordeste argentino

    Directory of Open Access Journals (Sweden)

    Silvana L. Maruñak

    2004-12-01

    Full Text Available Due to variability of venom components from the same species of snakes that inhabit different regions, particular properties of the venom of Crotalus durissus terrificus that inhabits the North-East of Argentina were studied. Gyroxin, a thrombin-like enzyme, was isolated from this venom by gel filtration and affinity chromatography, it was found to be homogeneous according to SDS-PAGE, with a molecular weight of 33 kDa. "Gyroxin syndrome" in mice was tested and it showed changes in the animal behavior, confirming that the isolated thrombin-like enzyme is gyroxin. Effects of this enzyme and the crude venom on mice plasmatic fibrinogen levels were determined. The mice plasma fibrinogen decreased rapidly until incoagulability during the first hour after thrombin-Iike enzyme injection, then reaching its normal level 10 hours after injection; whereas crude venom resulted in a 60% decrease of the mice plasma fibrinogen, reaching its normal level after the same period of time. After 1 hour of gyroxin inoculation, intravascular coagulation was observed in histological cuttings of lung, cardiac muscle and liver. The isolated enzyme showed strong hydrolyzing activity on fibrinogen and fibrin in vitro, whereas the crude venom exhibited weak hydrolyzing activity on both substrates. It is probable that this very low activity is due to the low percentage of the enzyme in the crude venom. Decreasing of plasmatic fibrinogen levels may be due to either the coagulant or hydrolyzing actions of the enzyme.Teniendo en cuenta la variabilidad de los componentes del veneno de serpientes de una misma especie que habitan regiones diferentes, se decidió estudiar las propiedades particulares del veneno de Crotalus durissus terrificus que habita el nordeste de Argentina, Giroxina, una enzima con actividad trombínica, fue aislada del veneno por cromatografía de filtración por gel y de afinidad; se comprobó su homogeneidad y se determinó su peso molecular, 33 kDa, por

  15. Foundations of High-Pressure Thermal Plasmas

    Science.gov (United States)

    Murphy, Anthony B.; Uhrlandt, Dirk

    2018-06-01

    An introduction to the main methods used to produce, model and measure thermal plasmas is provided, with emphasis on the differences between thermal plasmas and other types of processing plasmas. The critical properties of thermal plasmas are explained in physical terms and their importance in different applications is considered. The characteristics, and advantages and disadvantages, of the different main types of thermal plasmas (transferred and non-transferred arcs, radio-frequency inductively-coupled plasmas and microwave plasmas) are discussed. The methods by which flow is stabilized in arc plasmas are considered. The important concept of local thermodynamic equilibrium (LTE) is explained, leading into a discussion of the importance of thermophysical properties, and their calculation in LTE and two-temperature plasmas. The standard equations for modelling thermal plasmas are presented and contrasted with those used for non-equilibrium plasmas. Treatments of mixed-gas and non-LTE plasmas are considered, as well as the sheath regions adjacent to electrodes. Finally, the main methods used for electrical, optical, spectroscopic and laser diagnostics of thermal plasmas are briefly introduced, with an emphasis on the required assumptions for their reliable implementation, and the specific requirements of thermal plasmas.

  16. Renal Amyloidosis Associated With 5 Novel Variants in the Fibrinogen A Alpha Chain Protein

    Directory of Open Access Journals (Sweden)

    Dorota Rowczenio

    2017-05-01

    Discussion: We report 6 novel mutations in the FGA gene: 5 were associated with renal fibrinogen A alpha chain amyloidosis and 1 was found to be incidental to light-chain amyloid deposits discovered in a patient with a plasma cell dyscrasia. Clinical awareness and suspicion of hereditary amyloidosis corroborated by genetic analysis and adequate typing using combined immunohistochemistry and laser microdissection and mass spectrometry is valuable to avoid misdiagnosis, especially when a family history of amyloidosis is absent.

  17. Emission spectroscopy of highly ionized high-temperature plasma jets

    Energy Technology Data Exchange (ETDEWEB)

    Belevtsev, A A; Chinnov, V F; Isakaev, E Kh [Associated Institute for High Temperatures, Russian Academy of Sciences Izhorskaya 13/19, Moscow, 125412 (Russian Federation)

    2006-08-01

    This paper deals with advanced studies on the optical emission spectroscopy of atmospheric pressure highly ionized high-temperature argon and nitrogen plasma jets generated by a powerful arc plasmatron. The emission spectra are taken in the 200-1000 nm range with a spectral resolution of {approx}0.01-0.02 nm. The exposure times are 6 x 10{sup -6}-2 x 10{sup -2} s, the spatial resolution is 0.02-0.03 mm. The recorded jet spectra are abundant in spectral lines originating from different ionization stages. In nitrogen plasmas, tens of vibronic bands are also observed. To interpret and process these spectra such that plasma characteristics can be derived, a purpose-developed automated processing system is applied. The use of a CCD camera at the spectrograph output allows a simultaneous recording of the spectral and chord intensity distributions of spectral lines, which can yet belong to the overlapped spectra of the first and second orders of interference. The modern optical diagnostic means and methods used permit the determination of spatial distributions of electron number densities and temperatures and evaluation of rotational temperatures. The radial profiles of the irradiating plasma components can also be obtained. Special attention is given to the method of deriving rotational temperatures using vibronic bands with an incompletely identified rotational structure.

  18. Multiethnic meta-analysis of genome-wide association studies in >100 000 subjects identifies 23 fibrinogen-associated Loci but no strong evidence of a causal association between circulating fibrinogen and cardiovascular disease

    NARCIS (Netherlands)

    Sabater-Lleal, M.; Huang, J.; Chasman, D.I.; Naitza, S.; Dehghan, A.; Johnson, A.D.; Teumer, A.; Reiner, A.P.; Folkersen, L.; Basu, S.; Rudnicka, A.R.; Trompet, S.; Mälarstig, A.; Baumert, J.; Bis, J.C.; Guo, X.; Hottenga, J.J.; Shin, S.Y.; Lopez, L.M.; Lahti, J.; Tanaka, T.; Yanek, L.R.; Oudot-Mellakh, T.; Wilson, J.F.; Navarro, P.; Huffman, J.E.; Zemunik, T.; Redline, S.; Mehra, R.; Pulanic, D.; Rudan, I.; Wright, A.F.; Kolcic, I.; Polasek, O.; Wild, S.H.; Campbell, H.; Curb, J.D.; Wallace, R.; Liu, S.; Eaton, C.B.; Becker, D.M.; Becker, L.C.; Bandinelli, S.; Räikkönen, K.; Widén, E.; Palotie, A.; Fornage, M.; Green, D.; Gross, M.; Davies, G.E.; Harris, S.E.; Liewald, D.C.; Starr, J.M.; Williams, F.M.; Grant, P.J.; Spector, T.D.; Strawbridge, R.J.; Silveira, A.; Sennblad, B.; Rivadeneira, F.; Uitterlinden, A.G.; Franco, O.H.; Hofman, A.; van Dongen, J.; Willemsen, G.; Boomsma, D.I.; Yao, J.; Swords Jenny, N.; Haritunians, T.; McKnight, B.; Lumley, T.; Taylor, K.D.; Rotter, J.I.; Psaty, B.M.; Peters, A.; Gieger, C.; Illig, T.; Grotevendt, A.; Homuth, G.; Völzke, H.; Kocher, T.; Goel, A.; Franzosi, M.G.; Seedorf, U.; Clarke, R.; Steri, M.; Tarasov, K.V.; Sanna, S.; Schlessinger, D.; Stott, D.J.; Sattar, N.; Buckley, B.M.; Rumley, A.; Lowe, G.D.; McArdle, W.L.; Chen, M.H.; Tofler, G.H.; Song, J.; Boerwinkle, E.; Folsom, A.R.; Rose, L.M.; Franco-Cereceda, A.; Teichert, M.; Ikram, M.A.; Mosley, T.H.; Bevan, S.; Dichgans, M.; Rothwell, P.M.; Sudlow, C.L.; Hopewell, J.C.; Chambers, J.C.; Saleheen, D.; Kooner, J.S.; Danesh, J.; Nelson, C.P.; Erdmann, J.; Reilly, M.P.; Kathiresan, S.; Schunkert, H.; Morange, P.E.; Ferrucci, L.; Eriksson, J.G.; Jacobs, D.; Deary, I.J.; Soranzo, N.; Witteman, J.C.; de Geus, E.J.C.; Tracy, R.P.; Hayward, C.; Koenig, W.; Cucca, F.; Jukema, J.W.; Eriksson, P.; Seshadri, S.; Markus, H.S.; Watkins, H.; Samani, N.J.; Wallaschofski, H.; Smith, N.L.; Tregouet, D.A.; Ridker, P.M.; Tang, W.; Strachan, D.P.; Hamsten, A.; O'Donnell, C.J.

    2013-01-01

    BACKGROUND-: Estimates of the heritability of plasma fibrinogen concentration, an established predictor of cardiovascular disease, range from 34% to 50%. Genetic variants so far identified by genome-wide association studies explain only a small proportion (<2%) of its variation. METHODS AND

  19. Multiethnic meta-analysis of genome-wide association studies in >100 000 subjects identifies 23 fibrinogen-associated Loci but no strong evidence of a causal association between circulating fibrinogen and cardiovascular disease

    NARCIS (Netherlands)

    Sabater-Lleal, M.; Huang, J.; Chasman, D.; Naitza, S.; Dehghan, A.; Johnson, A.D.; Teumer, A.; Reiner, A.P.; Folkersen, L.; Basu, S.; Rudnicka, A.R.; Trompet, S.; Malarstig, A.; Baumert, J.; Bis, J.C.; Guo, X.; Hottenga, J.J.; Shin, S.Y.; Lopez, L.M.; Lahti, J.; Tanaka, T.; Yanek, L.R.; Oudot-Mellakh, T.; Wilson, J.F.; Navarro, P.; Huffman, J.E.; Zemunik, T.; Redline, S.; Mehra, R.; Pulanic, D.; Rudan, I.; Wright, A.F.; Kolcic, I.; Polasek, O.; Wild, S.H.; Campbell, H.; Curb, J.D.; Wallace, R.; Liu, S.; Eaton, C.B.; Becker, D.M.; Becker, L.C.; Bandinelli, S.; Raikkonen, K.; Widen, E.; Palotie, A.; Fornage, M.; Green, D.; Gross, M.; Davies, G.; Harris, S.E.; Liewald, D.C.; Starr, J.M.; Williams, F.M.; Grant, P.J.; Spector, T.D.; Strawbridge, R.J.; Silveira, A.; Sennblad, B.; Rivadeneira, F.; Uitterlinden, A.G.; Franco, O.H.; Hofman, A.; Dongen, J. Van; Willemsen, G.; Boomsma, D.I.; Yao, J.; Jenny, N. Swords; Haritunians, T.; McKnight, B.; Lumley, T.; Taylor, K.D.; Rotter, J.I.; Psaty, B.M.; Peters, A.; Gieger, C.; Illig, T.; Grotevendt, A.; Homuth, G.; Volzke, H.; Kocher, T.; Goel, A.; Franzosi, M.G.; Seedorf, U.; Clarke, R.; Steri, M.; Tarasov, K.V.; Sanna, S.; Schlessinger, D.; Stott, D.J.; Sattar, N.; Buckley, B.M.; Rumley, A.; Lowe, G.D.; McArdle, W.L.; Chen, M.H.; Tofler, G.H.; Song, J.; Boerwinkle, E.; Folsom, A.R.; Teichert, M.; et al.,

    2013-01-01

    BACKGROUND: Estimates of the heritability of plasma fibrinogen concentration, an established predictor of cardiovascular disease, range from 34% to 50%. Genetic variants so far identified by genome-wide association studies explain only a small proportion (<2%) of its variation. METHODS AND RESULTS:

  20. Interindividual variation in the response by fibrinogen, C-reactive protein and interleukin-6 to yellow fever vaccination

    NARCIS (Netherlands)

    Verschuur, M.; Beek, M.T. van der; Tak, H.S.; Visser, L.G.; Maat, M.P.M. de

    2004-01-01

    The acute phase reaction is important in many disease processes. Habitual levels of the acute phase proteins fibrinogen, C-reactive protein (CRP) and interleukin-6 (IL-6) are associated with an increased risk of cardiovascular disease, but the dynamic variation of plasma levels of acute phase

  1. Biochemical and biological properties of the binding of human fibrinogen to M protein in group A streptococci

    International Nuclear Information System (INIS)

    Whitnack, E.; Beachey, E.H.

    1985-01-01

    Fibrinogen is known to bind to group A streptococci and precipitate with extracts containing streptococcal M protein. The authors have previously shown that the binding of fibrinogen to M-positive streptococci prevents opsonization by complement and protects that organism from phagocytosis in nonimmune blood. In the present study, they used 3 H-labeled fibrinogen, a highly purified peptide fragment of type 24 M protein (pep M24), and anti-pep M sera to show that fibrinogen binds to M-positive streptococci with high affinity; occupation of the high-affinity binding sites suffices to protect the organism from phagocytosis; proteolytic treatments that remove M protein from streptococcal cells abolish binding; binding is competitively inhibited by anti-pep M sera; pep M24 precipitates fibrinogen; and binding to type 24 cells is inhibited by pep M24. They conclude that M protein is the cell surface structure principally responsible for binding fibrinogen on the surface of M-positive streptococci and that this binding contributes to the known antiopsonic property of M proteins

  2. Improved GAMMA 10 tandem mirror confinement in high density plasma

    International Nuclear Information System (INIS)

    Yatsu, K.; Cho, T.; Higaki, H.; Hirata, M.; Hojo, H.; Ichimura, M.; Ishii, K.; Ishimoto, Y.; Itakura, A.; Katanuma, I.; Kohagura, J.; Minami, R.; Nakashima, Y.; Numakura, T.; Saito, T.; Saosaki, S.; Takemura, Y.; Tatematsu, Y.; Yoshida, M.; Yoshikawa, M.

    2003-01-01

    GAMMA 10 experiments have advanced in high density experiments after the last IAEA fusion energy conference in 2000 where we reported the production of the high density plasma through use of ion cyclotron range of frequency heating at a high harmonic frequency and neutral beam injection in the anchor cells. However, the diamagnetic signal of the plasma decreased when electron cyclotron resonance heating was applied for the potential formation. Recently a high density plasma has been obtained without degradation of the diamagnetic signal and with much improved reproducibility than before. The high density plasma was attained through adjustment of the spacing of the conducting plates installed in the anchor transition regions. The potential confinement of the plasma has been extensively studied. Dependences of the ion confinement time, ion-energy confinement time and plasma confining potential on plasma density were obtained for the first time in the high density region up to a density of 4x10 18 m -3 . (author)

  3. Serum bilirubin levels are inversely associated with PAI-1 and fibrinogen in Korean subjects.

    Science.gov (United States)

    Cho, Hyun Sun; Lee, Sung Won; Kim, Eun Sook; Shin, Juyoung; Moon, Sung Dae; Han, Je Ho; Cha, Bong Yun

    2016-01-01

    Oxidative stress may contribute to atherosclerosis and increased activation of the coagulation pathway. Bilirubin may reduce activation of the hemostatic system to inhibit oxidative stress, which would explain its cardioprotective properties shown in many epidemiological studies. This study investigated the association of serum bilirubin with fibrinogen and plasminogen activator inhibitor-1 (PAI-1), respectively. A cross-sectional analysis was performed on 968 subjects (mean age, 56.0 ± 11.2 years; 61.1% men) undergoing a general health checkup. Serum biochemistry was analyzed including bilirubin subtypes, insulin resistance (using homeostasis model of assessment [HOMA]), C-reactive protein (CRP), fibrinogen, and PAI-1. Compared with subjects with a total bilirubin (TB) concentration of 17.1 μmol/L had a smaller waist circumference, a lower triglyceride level, a lower prevalence of metabolic syndrome, and decreased HOMA-IR and CRP levels. Correlation analysis revealed linear relationships of fibrinogen with TB and direct bilirubin (DB), whereas PAI-1 was correlated with DB. After adjustment for confounding factors, bilirubin levels were inversely associated with fibrinogen and PAI-1 levels, respectively. Multivariate regression models showed a negative linear relationship between all types of bilirubin and fibrinogen, whereas there was a significant linear relationship between PAI-1 and DB. High bilirubin concentrations were independently associated with low levels of fibrinogen and PAI-1, respectively. The association between TB and PAI-1 was confined to the highest TB concentration category whereas DB showed a linear association with PAI-1. Bilirubin may protect against the development of atherothrombosis by reducing the hemostatic response. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Super-high magnetic fields in spatially inhomogeneous plasma

    International Nuclear Information System (INIS)

    Nastoyashchiy, Anatoly F.

    2012-01-01

    The new phenomenon of a spontaneous magnetic field in spatially inhomogeneous plasma is found. The criteria for instability are determined, and both the linear and nonlinear stages of the magnetic field growth are considered; it is shown that the magnetic field can reach a considerable magnitude, namely, its pressure can be comparable with the plasma pressure. Especially large magnetic fields can arise in hot plasma with a high electron density, for example, in laser-heated plasma. In steady-state plasma, the magnetic field can be self-sustaining. The considered magnetic fields may play an important role in thermal insulation of the plasma. (author)

  5. Integrated plasma control for high performance tokamaks

    International Nuclear Information System (INIS)

    Humphreys, D.A.; Deranian, R.D.; Ferron, J.R.; Johnson, R.D.; LaHaye, R.J.; Leuer, J.A.; Penaflor, B.G.; Walker, M.L.; Welander, A.S.; Jayakumar, R.J.; Makowski, M.A.; Khayrutdinov, R.R.

    2005-01-01

    Sustaining high performance in a tokamak requires controlling many equilibrium shape and profile characteristics simultaneously with high accuracy and reliability, while suppressing a variety of MHD instabilities. Integrated plasma control, the process of designing high-performance tokamak controllers based on validated system response models and confirming their performance in detailed simulations, provides a systematic method for achieving and ensuring good control performance. For present-day devices, this approach can greatly reduce the need for machine time traditionally dedicated to control optimization, and can allow determination of high-reliability controllers prior to ever producing the target equilibrium experimentally. A full set of tools needed for this approach has recently been completed and applied to present-day devices including DIII-D, NSTX and MAST. This approach has proven essential in the design of several next-generation devices including KSTAR, EAST, JT-60SC, and ITER. We describe the method, results of design and simulation tool development, and recent research producing novel approaches to equilibrium and MHD control in DIII-D. (author)

  6. Two cases of congenital dysfibrinogenemia associated with thrombosis - Fibrinogen Praha III and Fibrinogen Plzen

    Czech Academy of Sciences Publication Activity Database

    Kotlín, R.; Reicheltová, Z.; Malý, M.; Suttnar, J.; Sobotková, A.; Salaj, P.; Hirmerová, J.; Riedel, Tomáš; Dyr, J. E.

    2009-01-01

    Roč. 102, č. 3 (2009), s. 479-486 ISSN 0340-6245 R&D Projects: GA AV ČR KAN200670701 Institutional research plan: CEZ:AV0Z40500505 Keywords : dysfibrinogenemia * fibrinogen * missense mutation Subject RIV: CD - Macromolecular Chemistry Impact factor: 4.451, year: 2009

  7. High-Speed Imaging of Dusty Plasma Instabilities

    International Nuclear Information System (INIS)

    Tawidian, H.; Mikikian, M.; Lecas, T.; Boufendi, L.; Coueedel, L.; Vallee, O.

    2011-01-01

    Dust particles in a plasma acquire negative charges by capturing electrons. If the dust particle density is high, a huge loss of free electrons can trigger unstable behaviors in the plasma. Several types of plasma behaviors are analyzed thanks to a high-speed camera like dust particle growth instabilities (DPGI) and a new phenomenon called plasma spheroids. These small plasma spheroids are about a few mm, have a slightly enhanced luminosity, and are observed in the vicinity of the electrodes. Different behaviors are identified for these spheroids like a rotational motion, or a chaotic regime (fast appearance and disappearance).

  8. High-Speed Imaging of Dusty Plasma Instabilities

    Science.gov (United States)

    Tawidian, H.; Couëdel, L.; Mikikian, M.; Lecas, T.; Boufendi, L.; Vallée, O.

    2011-11-01

    Dust particles in a plasma acquire negative charges by capturing electrons. If the dust particle density is high, a huge loss of free electrons can trigger unstable behaviors in the plasma. Several types of plasma behaviors are analyzed thanks to a high-speed camera like dust particle growth instabilities (DPGI) and a new phenomenon called plasma spheroids. These small plasma spheroids are about a few mm, have a slightly enhanced luminosity, and are observed in the vicinity of the electrodes. Different behaviors are identified for these spheroids like a rotational motion, or a chaotic regime (fast appearance and disappearance).

  9. Propagation of high frequency electrostatic surface waves along the planar interface between plasma and dusty plasma

    Science.gov (United States)

    Mishra, Rinku; Dey, M.

    2018-04-01

    An analytical model is developed that explains the propagation of a high frequency electrostatic surface wave along the interface of a plasma system where semi-infinite electron-ion plasma is interfaced with semi-infinite dusty plasma. The model emphasizes that the source of such high frequency waves is inherent in the presence of ion acoustic and dust ion acoustic/dust acoustic volume waves in electron-ion plasma and dusty plasma region. Wave dispersion relation is obtained for two distinct cases and the role of plasma parameters on wave dispersion is analyzed in short and long wavelength limits. The normalized surface wave frequency is seen to grow linearly for lower wave number but becomes constant for higher wave numbers in both the cases. It is observed that the normalized frequency depends on ion plasma frequencies when dust oscillation frequency is neglected.

  10. Research on high energy density plasmas and applications

    International Nuclear Information System (INIS)

    1999-01-01

    Recently, technologies on lasers, accelerators, and pulse power machines have been significantly advanced and input power density covers the intensity range from 10 10 W/cm 2 to higher than 10 20 W/cm 2 . As the results, high pressure gas and solid targets can be heated up to very high temperature to create hot dense plasmas which have never appeared on the earth. The high energy density plasmas opened up new research fields such as inertial confinement fusion, high brightness X-ray radiation sources, interiors of galactic nucleus,supernova, stars and planets, ultra high pressure condensed matter physics, plasma particle accelerator, X-ray laser, and so on. Furthermore, since these fields are intimately connected with various industrial sciences and technologies, the high energy density plasma is now studied in industries, government institutions, and so on. This special issue of the Journal of Plasma Physics and Nuclear Fusion Research reviews the high energy density plasma science for the comprehensive understanding of such new fields. In May, 1998, the review committee for investigating the present status and the future prospects of high energy density plasma science was established in the Japan Society of Plasma Science and Nuclear Fusion Research. We held three committee meetings to discuss present status and critical issues of research items related to high energy density plasmas. This special issue summarizes the understandings of the committee. This special issue consists of four chapters: They are Chapter 1: Physics important in the high energy density plasmas, Chapter 2: Technologies related to the plasma generation; drivers such as lasers, pulse power machines, particle beams and fabrication of various targets, Chapter 3: Plasma diagnostics important in high energy density plasma experiments, Chapter 4: A variety of applications of high energy density plasmas; X-ray radiation, particle acceleration, inertial confinement fusion, laboratory astrophysics

  11. Skeletal changes in congenital fibrinogen abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lagier, R.; Bouvier, C.A.; van Strijthem, N.

    1980-01-01

    We report anatomico-radiologic study of humerus, femur, and tibia from a case of total congenital afibrinogenemia. Juxtatrabecular hemorrhages occur mainly in metaphyses and seem to be related to normal lines of stress. They may lead to the formation of intraosseous cysts and to a remodelling of bone trabeculae. The radiologic lesions in a second case, diagnosed as congenital dysfibrinogenemia, are similar to those found in Case 1 (femoral trabeculae remodelling) but also resemble some alterations described in hemophilia (pseudotumor of the right iliac bone). Anatomic study of the lesions in Case 2 was not possible. The significance of these observations could be better defined by a more extended skeletal study (radiologic and when feasible anatomic) of patients with congenital clotting defects and especially with inherited disorders of the fibrinogen molecule. It would also be worthwhile investigating manifest or latent hemostatic disorders (particularly at the fibrinogen level) in patients with solitary or aneurysmal bone cysts, and even with bone infarct or unexplained trabecular remodelling.

  12. Atomic processes in high-density plasmas

    International Nuclear Information System (INIS)

    More, R.M.

    1982-01-01

    This review covers dense atomic plasmas such as that produced in inertial confinement fusion. The target implosion physics along with the associated atomic physics, i.e., free electron collision phenomena, electron states I, electron states II, and nonequilibrium plasma states are described

  13. High-Current Plasma Electron Sources

    International Nuclear Information System (INIS)

    Gushenets, J.Z.; Krokhmal, V.A.; Krasik, Ya. E.; Felsteiner, J.; Gushenets, V.

    2002-01-01

    In this report we present the design, electrical schemes and preliminary results of a test of 4 different electron plasma cathodes operating under Kg h-voltage pulses in a vacuum diode. The first plasma cathode consists of 6 azimuthally symmetrically distributed arc guns and a hollow anode having an output window covered by a metal grid. Plasma formation is initiated by a surface discharge over a ceramic washer placed between a W-made cathode and an intermediate electrode. Further plasma expansion leads to a redistribution of the discharge between the W-cathode and the hollow anode. An accelerating pulse applied between the output anode grid and the collector extracts electrons from this plasma. The operation of another plasma cathode design is based on Penning discharge for preliminary plasma formation. The main glow discharge occurs between an intermediate electrode of the Penning gun and the hollow anode. To keep the background pressure in the accelerating gap at P S 2.5x10 4 Torr either differential pumping or a pulsed gas puff valve were used. The operation of the latter electron plasma source is based on a hollow cathode discharge. To achieve a sharp pressure gradient between the cathode cavity and the accelerating gap a pulsed gas puff valve was used. A specially designed ferroelectric plasma cathode initiated plasma formation inside the hollow cathode. This type of the hollow cathode discharge ignition allowed to achieve a discharge current of 1.2 kA at a background pressure of 2x10 4 Torr. All these cathodes were developed and initially tested inside a planar diode with a background pressure S 2x10 4 Torr under the same conditions: accelerating voltage 180 - 300 kV, pulse duration 200 - 400 ns, electron beam current - 1 - 1.5 kA, and cross-sectional area of the extracted electron beam 113 cm 2

  14. Pulsed high-density plasmas for advanced dry etching processes

    International Nuclear Information System (INIS)

    Banna, Samer; Agarwal, Ankur; Cunge, Gilles; Darnon, Maxime; Pargon, Erwine; Joubert, Olivier

    2012-01-01

    Plasma etching processes at the 22 nm technology node and below will have to satisfy multiple stringent scaling requirements of microelectronics fabrication. To satisfy these requirements simultaneously, significant improvements in controlling key plasma parameters are essential. Pulsed plasmas exhibit considerable potential to meet the majority of the scaling challenges, while leveraging the broad expertise developed over the years in conventional continuous wave plasma processing. Comprehending the underlying physics and etching mechanisms in pulsed plasma operation is, however, a complex undertaking; hence the full potential of this strategy has not yet been realized. In this review paper, we first address the general potential of pulsed plasmas for plasma etching processes followed by the dynamics of pulsed plasmas in conventional high-density plasma reactors. The authors reviewed more than 30 years of academic research on pulsed plasmas for microelectronics processing, primarily for silicon and conductor etch applications, highlighting the potential benefits to date and challenges in extending the technology for mass-production. Schemes such as source pulsing, bias pulsing, synchronous pulsing, and others in conventional high-density plasma reactors used in the semiconductor industry have demonstrated greater flexibility in controlling critical plasma parameters such as ion and radical densities, ion energies, and electron temperature. Specifically, plasma pulsing allows for independent control of ion flux and neutral radicals flux to the wafer, which is key to eliminating several feature profile distortions at the nanometer scale. However, such flexibility might also introduce some difficulty in developing new etching processes based on pulsed plasmas. Therefore, the main characteristics of continuous wave plasmas and different pulsing schemes are compared to provide guidelines for implementing different schemes in advanced plasma etching processes based on

  15. Quality asurance of iodinated (125 I) human fibrinogen

    International Nuclear Information System (INIS)

    Vines, E.J.

    1980-05-01

    The radiopharmaceutical iodinated ( 125 I) human fibrinogen is currently used for the detection of deep vein thrombosis in the legs, a fairly common post-surgical complication. A comprehensive quality assurance programme for ( 125 I) - human fibrinogen has been determined for routine use at the Australian Radiation Laboratory, with adaptions necessary for hospital quality control testing

  16. Two novel mutations in the fibrinogen .gamma. nodule

    Czech Academy of Sciences Publication Activity Database

    Kotlín, R.; Pastva, O.; Štikarová, J.; Hlaváčková, A.; Suttnar, J.; Chrastinová, L.; Riedel, Tomáš; Salaj, P.; Dyr, J. E.

    2014-01-01

    Roč. 134, č. 4 (2014), s. 901-908 ISSN 0049-3848 R&D Projects: GA ČR GBP205/12/G118 Institutional support: RVO:61389013 Keywords : abnormal fibrinogens * hereditary coagulation disorders * fibrinogen Subject RIV: BO - Biophysics Impact factor: 2.447, year: 2014

  17. Pre-emptive treatment with fibrinogen concentrate for postpartum haemorrhage

    DEFF Research Database (Denmark)

    Wikkelsø, A J; Edwards, H M; Afshari, A

    2015-01-01

    BACKGROUND: In early postpartum haemorrhage (PPH), a low concentration of fibrinogen is associated with excessive subsequent bleeding and blood transfusion. We hypothesized that pre-emptive treatment with fibrinogen concentrate reduces the need for red blood cell (RBC) transfusion in patients...... and the fibrinogen concentration at inclusion. The primary outcome was RBC transfusion up to 6 weeks postpartum. Secondary outcomes were total blood loss, total amount of blood transfused, occurrence of rebleeding, haemoglobin ... concentrate, thereby significantly increasing fibrinogen concentration compared with placebo by 0.40 g litre(-1) (95% confidence interval, 0.15-0.65; P=0.002). Postpartum blood transfusion occurred in 25 (20%) of the fibrinogen group and 26 (22%) of the placebo group (relative risk, 0.95; 95% confidence...

  18. Exploration by radioactive fibrinogen of intrarenal coagulation phenomena. Preliminary results

    International Nuclear Information System (INIS)

    Simon, Jacques.

    1974-01-01

    The participation of fibrin deposits in kidney pathology was studied by the use of a radioactive tracer involved in the coagulation phenomenon: iodine 131-labelled fibrinogen. The isotopic exploration consists of a fibrinogen kinetics study combined with external counting over the kidney regions. The different stages of the procedure are described: separation, purification and labelling of fibrinogen; characteristics of the radioactive fibrinogen used; practical details of the examination itself; data analysis method. A chapter devoted to verifications and discussions of the procedure is followed by a report on the exploration of intrarenal coagulation phenomena in 30 kidney disease patients. In conclusion, the study of fibrinogen kinetics is considered as the most suitable method to detect local or slight intravascular coagulation phenomena. The sensitivity of the isotopic exploration is very satisfactory. The main criticism directed against this method is that the exploration is general and therefore blind [fr

  19. Miniaturized high performance sensors for space plasmas

    International Nuclear Information System (INIS)

    Young, D.T.

    1996-01-01

    Operating under ever more constrained budgets, NASA has turned to a new paradigm for instrumentation and mission development in which smaller, faster, better, cheaper is of primary consideration for future space plasma investigations. The author presents several examples showing the influence of this new paradigm on sensor development and discuss certain implications for the scientific return from resource constrained sensors. The author also discusses one way to improve space plasma sensor performance which is to search out new technologies, measurement techniques and instrument analogs from related fields including among others, laboratory plasma physics

  20. Workshop on extremely high energy density plasmas and their diagnostics

    International Nuclear Information System (INIS)

    Ishii, Shozo

    2001-09-01

    Compiled are the papers presented at the workshop on 'Extremely High Energy Density Plasmas and Their Diagnostics' held at National Institute for Fusion Science. The papers cover physics and applications of extremely high-energy density plasmas such as dense z-pinch, plasma focus, and intense pulsed charged beams. Separate abstracts were presented for 7 of the papers in this report. The remaining 25 were considered outside the subject scope of INIS. (author)

  1. Workshop on extremely high energy density plasmas and their diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Shozo (ed.)

    2001-09-01

    Compiled are the papers presented at the workshop on 'Extremely High Energy Density Plasmas and Their Diagnostics' held at National Institute for Fusion Science. The papers cover physics and applications of extremely high-energy density plasmas such as dense z-pinch, plasma focus, and intense pulsed charged beams. Separate abstracts were presented for 7 of the papers in this report. The remaining 25 were considered outside the subject scope of INIS. (author)

  2. Heterozygosity for fibrinogen results in efficient resolution of kidney ischemia reperfusion injury.

    Directory of Open Access Journals (Sweden)

    Amrendra Kumar Ajay

    Full Text Available Fibrinogen (Fg has been recognized to play a central role in coagulation, inflammation and tissue regeneration. Several studies have used Fg deficient mice (Fg(-/- in comparison with heterozygous mice (Fg(+/- to point the proinflammatory role of Fg in diverse pathological conditions and disease states. Although Fg(+/- mice are considered 'normal', plasma Fg is reduced to ~75% of the normal circulating levels present in wild type mice (Fg(+/+. We report that this reduction in Fg protein production in the Fg(+/- mice is enough to protect them from kidney ischemia reperfusion injury (IRI as assessed by tubular injury, kidney dysfunction, necrosis, apoptosis and inflammatory immune cell infiltration. Mechanistically, we observed binding of Fg to ICAM-1 in kidney tissues of Fg(+/+ mice at 24 h following IRI as compared to a complete absence of binding observed in the Fg(+/- and Fg(-/- mice. Raf-1 and ERK were highly activated as evident by significantly higher phosphorylation in the Fg(+/+ kidneys at 24 h following IRI as compared to Fg(+/- and Fg(-/- mice kidneys. On the other hand Cyclin D1 and pRb, indicating higher cell proliferation, were significantly increased in the Fg(+/- and Fg(-/- as compared to Fg(+/+ kidneys. These data suggest that Fg heterozygosity allows maintenance of a critical balance of Fg that enables regression of initial injury and promotes faster resolution of kidney damage.

  3. Spectroscopic diagnostics of high temperature plasmas

    International Nuclear Information System (INIS)

    Moos, W.

    1990-01-01

    A three-year research program for the development of novel XUV spectroscopic diagnostics for magnetically confined fusion plasmas is proposed. The new diagnostic system will use layered synthetic microstructures (LSM) coated, flat and curved surfaces as dispersive elements in spectrometers and narrow band XUV filter arrays. In the framework of the proposed program we will develop impurity monitors for poloidal and toroidal resolved measurements on PBX-M and Alcator C-Mod, imaging XUV spectrometers for electron density and temperature fluctuation measurements in the hot plasma core in TEXT or other similar tokamaks and plasma imaging devices in soft x-ray light for impurity behavior studies during RF heating on Phaedrus T and carbon pellet ablation in Alcator C-Mod. Recent results related to use of multilayer in XUV plasma spectroscopy are presented. We also discuss the latest results reviewed to q o and local poloidal field measurements using Zeeman polarimetry

  4. Computational Simulation of High Energy Density Plasmas

    Science.gov (United States)

    2009-10-30

    the imploding liner. The PFS depends on a lithium barrier foil slowing the advance of deuterium up the coaxial gun to the corner. There the plasma ...the coaxial gun section, and Figure 4 shows the physical state of the plasma just prior to pinch. Figure 5 shows neutron yield reaching 1014 in this...details the channel geometry between the center cylinder and coaxial gas gun . The deuterium injection starts when the pressure of the deuterium gas in

  5. Identification and characterization of the fibrinogen-like domain of fibrinogen-related proteins in the mosquito, Anopheles gambiae, and the fruitfly, Drosophila melanogaster, genomes

    Directory of Open Access Journals (Sweden)

    Zhao Qin

    2005-09-01

    Full Text Available Abstract Background The fibrinogen-like (FBG domain, which consists of approximately 200 amino acid residues, has high sequence similarity to the C-terminal halves of fibrinogen β and γ chains. Fibrinogen-related proteins (FREPs, which contain FBG domains in their C-terminal region, are found universally in vertebrates and invertebrates. In invertebrates, FREPs are involved in immune responses and other aspects of physiology. To understand the complexity of this family in insects, we analyzed FREPs in the mosquito genome and made comparisons to FREPs in the fruitfly genome. Results By using the genome data of the mosquito, Anopheles gambiae, 53 FREPs were identified, whereas only 20 members were found in the Drosophila melanogaster genome. Using sequence profile analysis, we found that FBG domains have high sequence similarity and are highly conserved throughout the FBG domain region. By secondary structure analysis and comparison, the FBG domains of FREPs are predicted to function in recognition of carbohydrates and their derivatives on the surface of microorganisms in innate immunity. Conclusion Detailed sequence and structural analysis discloses that the FREP family contains FBG domains that have high sequence similarity in the A. gambiae genome. Expansion of the FREP family in mosquitoes during evolutionary history is mainly accounted for by a major expansion of the FBG domain architecture. The characterization of the FBG domains in the FREP family is likely to aid in the experimental analysis of the ability of mosquitoes to recognize parasites in innate immunity and physiologies associated with blood feeding.

  6. Highly Supersonic Ion Pulses in a Collisionless Magnetized Plasma

    DEFF Research Database (Denmark)

    Juul Rasmussen, Jens; Schrittwieser, R.

    1982-01-01

    The initial transient response of a collisionless plasma to a high positive voltage step is investigated. Four different pulses are observed. An electron plasma wave pulse is followed by an ion burst. The latter is overtaken and absorbed by a highly supersonic ion pulse. Thereafter, an ion...

  7. Analysis of plasma channels in mm-scale plasmas formed by high intensity laser beams

    International Nuclear Information System (INIS)

    Murakami, R; Habara, H; Iwawaki, T; Uematsu, Y; Tanaka, K A; Ivancic, S; Anderson, K; Haberberger, D; Stoeckl, C; Theobald, W; Sakagami, H

    2016-01-01

    A plasma channel created by a high intensity infrared laser beam was observed in a long scale-length plasma (L ∼ 240 μm) with the angular filter refractometry technique, which indicated a stable channel formation up to the critical density. We analyzed the observed plasma channel using a rigorous ray-tracing technique, which provides a deep understanding of the evolution of the channel formation. (paper)

  8. Turnover of radio-iodinated and biosynthetically labelled fibrinogen in rhesus monkeys

    International Nuclear Information System (INIS)

    Moza, A.K.

    1982-01-01

    Successful radio-iodination of monkey fibrinogen using a previously documented method for rabbit fibrinogen is reported. The label was securely bound to fibrinogen without any evidence of polymerisation. Turnover rates and other kinetic parameters of fibrinogen using 125 I-fibrinogen have been compared with those obtained with biosynthetically labelled donor 75 Se-fibrinogen. Both studies yielded identical results. The values for normal monkeys showed a half life of 43.8 +- 1.03 h with 125 I-fibrinogen and 47.15 +- 1.24 with 75 Se-fibrinogen. The turnover rate of endogenous 75 Se-fibrinogen following administration of 75 Se-selenomethionine has also been studied. The half disappearance time value of 100.34 h was much longer than the t1/2 values obtained with either 125 I or 75 Se-fibrinogen. This is believed to be due the staggered input of fibrinogen molecules from the liver. (author)

  9. Synergistic effect of signaling from receptors of soluble platelet agonists and outside-in signaling in formation of a stable fibrinogen-integrin αIIbβ3-actin cytoskeleton complex.

    Science.gov (United States)

    Budnik, Ivan; Shenkman, Boris; Savion, Naphtali

    2015-01-01

    Thrombus formation in the injured vessel wall is a highly complex process involving various blood-born components that go through specific temporal and spatial changes as observed by intravital videomicroscopy. Platelets bind transiently to the developing thrombus and may either become stably incorporated into or disengage from the thrombus. The aim of the present study was to reveal the processes involved in the formation of a stable thrombus. Platelet-rich plasma and washed platelets were studied by the aggregometer. The aggregate stability was challenged by eptifibatide. Platelet Triton-insoluble fraction was prepared and the actin and αIIb content in the cytoskeleton was analyzed by western blot. Maximal actin polymerization is achieved 1min after platelet activation while maximal αIIbβ3-actin cytoskeleton association requires 5 to 10min of activation and fibrinogen-mediated platelet-to-platelet bridging. Thus, actin polymerization is dependent on platelet activation and requires neither αIIbβ3 integrin occupation nor platelet aggregation. Formation of a stable aggregate requires platelet activation for more than 1min, complete increase in actin cytoskeleton fraction and partial association of αIIbβ3 with the actin cytoskeleton. However, direct αIIbβ3 activation is not sufficient for cytoskeleton complex formation. Thus, stable αIIbβ3-fibrinogen interaction, representing stable aggregate, is achieved after more than 1min agonist activation, involving inside-out and outside-in signaling but not after direct integrin activation, involving only outside-in signaling. Formation of a stable fibrinogen-αIIbβ3-actin cytoskeleton complex is the result of the combined effect of platelet stimulation by soluble agonists, activation of αIIbβ3, fibrinogen binding and platelet-to-platelet bridging. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. PULSION registered HP: Tunable, High Productivity Plasma Doping

    International Nuclear Information System (INIS)

    Felch, S. B.; Torregrosa, F.; Etienne, H.; Spiegel, Y.; Roux, L.; Turnbaugh, D.

    2011-01-01

    Plasma doping has been explored for many implant applications for over two decades and is now being used in semiconductor manufacturing for two applications: DRAM polysilicon counter-doping and contact doping. The PULSION HP is a new plasma doping tool developed by Ion Beam Services for high-volume production that enables customer control of the dominant mechanism--deposition, implant, or etch. The key features of this tool are a proprietary, remote RF plasma source that enables a high density plasma with low chamber pressure, resulting in a wide process space, and special chamber and wafer electrode designs that optimize doping uniformity.

  11. Development of high energy pulsed plasma simulator for plasma-lithium trench experiment

    Science.gov (United States)

    Jung, Soonwook

    To simulate detrimental events in a tokamak and provide a test-stand for a liquid lithium infused trench (LiMIT) device, a pulsed plasma source utilizing a theta pinch in conjunction with a coaxial plasma accelerator has been developed. An overall objective of the project is to develop a compact device that can produce 100 MW/m2 to 1 GW/m2 of plasma heat flux (a typical heat flux level in a major fusion device) in ~ 100 mus (≤ 0.1 MJ/m2) for a liquid lithium plasma facing component research. The existing theta pinch device, DEVeX, was built and operated for study on lithium vapor shielding effect. However, a typical plasma energy of 3 - 4 kJ/m2 is too low to study an interaction of plasma and plasma facing components in fusion devices. No or little preionized plasma, ringing of magnetic field, collisions of high energy particles with background gas have been reported as the main issues. Therefore, DEVeX is reconfigured to mitigate these issues. The new device is mainly composed of a plasma gun for a preionization source, a theta pinch for heating, and guiding magnets for a better plasma transportation. Each component will be driven by capacitor banks and controlled by high voltage / current switches. Several diagnostics including triple Langmuir probe, calorimeter, optical emission measurement, Rogowski coil, flux loop, and fast ionization gauge are used to characterize the new device. A coaxial plasma gun is manufactured and installed in the previous theta pinch chamber. The plasma gun is equipped with 500 uF capacitor and a gas puff valve. The increase of the plasma velocity with the plasma gun capacitor voltage is consistent with the theoretical predictions and the velocity is located between the snowplow model and the weak - coupling limit. Plasma energies measured with the calorimeter ranges from 0.02 - 0.065 MJ/m2 and increases with the voltage at the capacitor bank. A cross-check between the plasma energy measured with the calorimeter and the triple probe

  12. Evaporation of carbon using electrons of a high density plasma

    International Nuclear Information System (INIS)

    Muhl, S.; Camps, E.; Escobar A, L.; Garcia E, J.L.; Olea, O.

    1999-01-01

    The high density plasmas are used frequently in the preparation of thin films or surface modification, for example to nitridation. In these processes, are used mainly the ions and the neutrals which compose the plasma. However, the electrons present in the plasma are not used, except in the case of chemical reactions induced by collisions, although the electron bombardment usually get hot the work piece. Through the adequate polarization of a conductor material, it is possible to extract electrons from a high density plasma at low pressure, that could be gotten the evaporation of this material. As result of the interaction between the plasma and the electron flux with the vapor produced, this last will be ionized. In this work, it is reported the use of this novelty arrangement to prepare carbon thin films using a high density argon plasma and a high purity graphite bar as material to evaporate. It has been used substrates outside plasma and immersed in the plasma. Also it has been reported the plasma characteristics (temperature and electron density, energy and ions flux), parameters of the deposit process (deposit rate and ion/neutral rate) as well as the properties of the films obtained (IR absorption spectra and UV/Vis, elemental analysis, hardness and refractive index. (Author)

  13. Local thermodynamic equilibrium in rapidly heated high energy density plasmas

    International Nuclear Information System (INIS)

    Aslanyan, V.; Tallents, G. J.

    2014-01-01

    Emission spectra and the dynamics of high energy density plasmas created by optical and Free Electron Lasers (FELs) depend on the populations of atomic levels. Calculations of plasma emission and ionization may be simplified by assuming Local Thermodynamic Equilibrium (LTE), where populations are given by the Saha-Boltzmann equation. LTE can be achieved at high densities when collisional processes are much more significant than radiative processes, but may not be valid if plasma conditions change rapidly. A collisional-radiative model has been used to calculate the times taken by carbon and iron plasmas to reach LTE at varying densities and heating rates. The effect of different energy deposition methods, as well as Ionization Potential Depression are explored. This work shows regimes in rapidly changing plasmas, such as those created by optical lasers and FELs, where the use of LTE is justified, because timescales for plasma changes are significantly longer than the times needed to achieve an LTE ionization balance

  14. High Current, High Density Arc Plasma as a New Source for WiPAL

    Science.gov (United States)

    Waleffe, Roger; Endrizzi, Doug; Myers, Rachel; Wallace, John; Clark, Mike; Forest, Cary; WiPAL Team

    2016-10-01

    The Wisconsin Plasma Astrophysics Lab (WiPAL) has installed a new array of nineteen plasma sources (plasma guns) on its 3 m diameter, spherical vacuum vessel. Each gun is a cylindrical, molybdenum, washer-stabilized, arc plasma source. During discharge, the guns are maintained at 1.2 kA across 100 V for 10 ms by the gun power supply establishing a high density plasma. Each plasma source is fired independently allowing for adjustable plasma parameters, with densities varying between 1018 -1019 m-3 and electron temperatures of 5-15 eV. Measurements were characterized using a 16 tip Langmuir probe. The plasma source will be used as a background plasma for the magnetized coaxial plasma gun (MCPG), the Terrestrial Reconnection Experiment (TREX), and as the plasma source for a magnetic mirror experiment. Temperature, density, and confinement results will be presented. This work is supported by the DoE and the NSF.

  15. High Temperature Plasmas Theory and Mathematical Tools for Laser and Fusion Plasmas

    CERN Document Server

    Spatschek, Karl-Heinz

    2012-01-01

    Filling the gap for a treatment of the subject as an advanced course in theoretical physics with a huge potential for future applications, this monograph discusses aspects of these applications and provides theoretical methods and tools for their investigation. Throughout this coherent and up-to-date work the main emphasis is on classical plasmas at high-temperatures, drawing on the experienced author's specialist background. As such, it covers the key areas of magnetic fusion plasma, laser-plasma-interaction and astrophysical plasmas, while also including nonlinear waves and phenomena.

  16. High speed cine film studies of plasma behaviour and plasma surface interactions in tokamaks

    International Nuclear Information System (INIS)

    Goodall, D.H.J.

    1982-01-01

    High speed cine photography is a useful diagnostic aid for studying plasma behaviour and plasma surface interactions. Several workers have filmed discharges in tokamaks including ASDEX, DITE, DIVA, ISX, JFT2, TFR and PLT. These films are discussed and examples given of the observed phenomena which include plasma limiter interactions, diverted discharges, disruptions, magnetic islands and moving glowing objects often known as 'UFOs'. Examples of plasma structures in ASDEX and DITE not previously published are also given. The paper also reports experiments in DITE to determine the origin of UFOs. (orig.)

  17. High plasma rotation velocity and density transitions by biased electrodes in RF produced, magnetized plasma

    International Nuclear Information System (INIS)

    Matsuyama, Shoichiro; Shinohara, Shunjiro

    2001-01-01

    A large density profile modification was successfully obtained by voltage biasing to electrodes inserted in a RF (radio frequency) produced, magnetized plasma, and formation of strong shear of azimuthal plasma rotation velocity in a supersonic regime was found. For the case of biasing to an electrode near the central plasma region, two types of density transitions were observed in the outer plasma region: one was an oscillatory transition between two states, and the other was a transition from high to low density states with a large reduction of density fluctuations. (author)

  18. High plasma rotation velocity and density transitions by biased electrodes in RF produced, magnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, Shoichiro; Shinohara, Shunjiro [Kyushu Univ., Interdisciplinary Graduate School of Engineering Sciences, Fukuoka (Japan)

    2001-07-01

    A large density profile modification was successfully obtained by voltage biasing to electrodes inserted in a RF (radio frequency) produced, magnetized plasma, and formation of strong shear of azimuthal plasma rotation velocity in a supersonic regime was found. For the case of biasing to an electrode near the central plasma region, two types of density transitions were observed in the outer plasma region: one was an oscillatory transition between two states, and the other was a transition from high to low density states with a large reduction of density fluctuations. (author)

  19. MHD analysis of LHD high beta plasma

    International Nuclear Information System (INIS)

    Ichiguchi, K.; Nakajima, N.; Carreras, B.A.

    2003-01-01

    The nonlinear behavior of the interchange mode in the LHD plasma depends on the overlap of the vortices with different helicity. If the vortices are separated in the radial direction, each mode saturates mildly with generating the local flat regions in the pressure profile. In the case of the significant overlap of the vortices, the convection is enhanced and the sudden global reduction of the pressure occurs. Succession of the saturated pressure profile in the increase of beta can suppress the overlap. Self-organization of the pressure profile to suppress the overlap of the vortices can be the stabilizing mechanism in the LHD plasma. (orig.)

  20. Recent development in high energy plasma production techniques by the deflagration plasma gun

    International Nuclear Information System (INIS)

    Cheng, D.Y.; Chang, C.N.; Tripathi, P.P.

    1983-01-01

    This chapter reports experimental data and experience which establish the phenomenon of deflagration in plasma as unique and with quite different properties from the normal snowplow modes. Demonstrates that extremely high velocities and energies in plasma beams are possible with obvious applications in many field and, in particular, in fusion. Suggests that the potential of deflagration beams' scalability to very high energy quasi-neutral plasma beam is possible with present day technology. Discusses plasma deflagration in a T-tube; coaxial deflagration plasma guns; a typical deflagration gun and its operating procedures; electrical design considerations; kinetic theory point of view of the deflagration acceleration of particles; measurements and results; properties of the deflagration gun; applications; inertial confinement experiments; injection into magnetic confinement systems; interaction experiments; and highly energetic beams

  1. High-fat diet-induced plasma protein and liver changes in obese rats can be attenuated by melatonin supplementation.

    Science.gov (United States)

    Wongchitrat, Prapimpun; Klosen, Paul; Pannengpetch, Supitcha; Kitidee, Kuntida; Govitrapong, Piyarat; Isarankura-Na-Ayudhya, Chartchalerm

    2017-06-01

    Obesity triggers changes in protein expression in various organs that might participate in the pathogenesis of obesity. Melatonin has been reported to prevent or attenuate such pathological protein changes in several chronic diseases. However, such melatonin effects on plasma proteins have not yet been studied in an obesity model. Using a proteomic approach, we investigated the effect of melatonin on plasma protein profiles after rats were fed a high-fat diet (HFD) to induce obesity. We hypothesized that melatonin would attenuate abnormal protein expression in obese rats. After 10weeks of the HFD, animals displayed increased body weight and fat accumulation as well as increased glucose levels, indicating an obesity-induced prediabetes mellitus-like state. Two-dimensional gel electrophoresis and liquid chromatography-mass spectrometry/mass spectrometry revealed 12 proteins whose expression was altered in response to the HFD and the melatonin treatment. The altered proteins are related to the development of liver pathology, such as cirrhosis (α1-antiproteinase), thrombosis (fibrinogen, plasminogen), and inflammation (mannose-binding protein A, complement C4, complement factor B), contributing to liver steatosis or hepatic cell death. Melatonin treatment most probably reduced the severity of the HFD-induced obesity by reducing the amplitude of HFD-induced plasma protein changes. In conclusion, we identified several potential biomarkers associated with the progression of obesity and its complications, such as liver damage. Furthermore, our findings reveal melatonin's beneficial effect of attenuating plasma protein changes and liver pathogenesis in obese rats. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology

    Science.gov (United States)

    Rawat, R. S.

    2015-03-01

    The dense plasma focus (DPF), a coaxial plasma gun, utilizes pulsed high current electrical discharge to heat and compress the plasma to very high density and temperature with energy densities in the range of 1-10 × 1010 J/m3. The DPF device has always been in the company of several alternative magnetic fusion devices as it produces intense fusion neutrons. Several experiments conducted on many different DPF devices ranging over several order of storage energy have demonstrated that at higher storage energy the neutron production does not follow I4 scaling laws and deteriorate significantly raising concern about the device's capability and relevance for fusion energy. On the other hand, the high energy density pinch plasma in DPF device makes it a multiple radiation source of ions, electron, soft and hard x-rays, and neutrons, making it useful for several applications in many different fields such as lithography, radiography, imaging, activation analysis, radioisotopes production etc. Being a source of hot dense plasma, strong shockwave, intense energetic beams and radiation, etc, the DPF device, additionally, shows tremendous potential for applications in plasma nanoscience and plasma nanotechnology. In the present paper, the key features of plasma focus device are critically discussed to understand the novelties and opportunities that this device offers in processing and synthesis of nanophase materials using, both, the top-down and bottom-up approach. The results of recent key experimental investigations performed on (i) the processing and modification of bulk target substrates for phase change, surface reconstruction and nanostructurization, (ii) the nanostructurization of PLD grown magnetic thin films, and (iii) direct synthesis of nanostructured (nanowire, nanosheets and nanoflowers) materials using anode target material ablation, ablated plasma and background reactive gas based synthesis and purely gas phase synthesis of various different types of

  3. Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology

    International Nuclear Information System (INIS)

    Rawat, R S

    2015-01-01

    The dense plasma focus (DPF), a coaxial plasma gun, utilizes pulsed high current electrical discharge to heat and compress the plasma to very high density and temperature with energy densities in the range of 1-10 × 10 10 J/m 3 . The DPF device has always been in the company of several alternative magnetic fusion devices as it produces intense fusion neutrons. Several experiments conducted on many different DPF devices ranging over several order of storage energy have demonstrated that at higher storage energy the neutron production does not follow I 4 scaling laws and deteriorate significantly raising concern about the device's capability and relevance for fusion energy. On the other hand, the high energy density pinch plasma in DPF device makes it a multiple radiation source of ions, electron, soft and hard x-rays, and neutrons, making it useful for several applications in many different fields such as lithography, radiography, imaging, activation analysis, radioisotopes production etc. Being a source of hot dense plasma, strong shockwave, intense energetic beams and radiation, etc, the DPF device, additionally, shows tremendous potential for applications in plasma nanoscience and plasma nanotechnology. In the present paper, the key features of plasma focus device are critically discussed to understand the novelties and opportunities that this device offers in processing and synthesis of nanophase materials using, both, the top-down and bottom-up approach. The results of recent key experimental investigations performed on (i) the processing and modification of bulk target substrates for phase change, surface reconstruction and nanostructurization, (ii) the nanostructurization of PLD grown magnetic thin films, and (iii) direct synthesis of nanostructured (nanowire, nanosheets and nanoflowers) materials using anode target material ablation, ablated plasma and background reactive gas based synthesis and purely gas phase synthesis of various different types of

  4. Rf-biasing of highly idealized plasmas

    NARCIS (Netherlands)

    Westermann, R.H.J.; Blauw, M.A.; Goedheer, W.J.; Sanden, van de M.C.M.; Schmidt, J.; Simek, M.; Pekarek, S.; Prukner, V.

    2007-01-01

    Remote plasmas, which are subjected to a radio-frequency (RF) biased surface, have been investigated theoretically and experimentally for decades. The relation between the complex power (DC) voltage characteristics, the ion energy distribution and control losses of the ion bombardment are of

  5. Plasma instabilities in high electric fields

    DEFF Research Database (Denmark)

    Morawetz, K.; Jauho, Antti-Pekka

    1994-01-01

    expression is derived for the nonequilibrium dielectric function epsilon(K, omega). For certain values of momenta K and frequency omega, Imepsilon(K, omega) becomes negative, implying a plasma instability. This new instability exists only for strong electric fields, underlining its nonequilibrium origin....

  6. Plasma focusing and diagnosis of high energy particle beams

    International Nuclear Information System (INIS)

    Chen, Pisin.

    1990-09-01

    Various novel concepts of focusing and diagnosis of high energy charged particle beams, based on the interaction between the relativistic particle beam and the plasma, are reviewed. This includes overdense thin plasma lenses, and (underdense) adiabatic plasma lens, and two beam size monitor concepts. In addition, we introduce another mechanism for measuring flat beams based on the impulse received by heavy ions in an underdense plasma. Theoretical investigations show promise of focusing and diagnosing beams down to sizes where conventional methods are not possible to provide. 21 refs

  7. Plasma resonance in anisotropic layered high-Tc superconductors

    DEFF Research Database (Denmark)

    Sakai, Shigeki; Pedersen, Niels Falsig

    1999-01-01

    The plasma resonance is described theoretically by the inductive coupling model for a large stacked Josephson-junction system such as the intrinsic Josephson-junction array in anisotropic high- T-c superconductors. Eigenmodes of the plasma oscillation are analytically described and a numerical...

  8. Corrosion properties of plasma deposited high-alloy steel

    Czech Academy of Sciences Publication Activity Database

    Voleník, Karel; Pražák, M.; Kalabisová, E.; Kreislová, K.; Neufuss, Karel

    2002-01-01

    Roč. 47, - (2002), s. 243-254 ISSN 0001-7043 R&D Projects: GA ČR GA106/99/0298 Institutional research plan: CEZ:AV0Z2043910 Keywords : plasma deposits, high-alloy steel, polarization curves, corrosion test Subject RIV: BL - Plasma and Gas Discharge Physics

  9. Annotated bibliography of highly ionized atoms of importance to plasmas

    International Nuclear Information System (INIS)

    Schmieder, R.W.

    1975-04-01

    A bibliography is presented of the literature on highly ionized atoms which have relevance to plasmas. The bibliography is annotated with keywords, and indexed by subjects and authors. It should be of greatest use to researchers working on the problems of impurity cooling and diagnostics of CTR plasmas. (U.S.)

  10. High-beta plasma effects in a low-pressure helicon plasma

    International Nuclear Information System (INIS)

    Corr, C. S.; Boswell, R. W.

    2007-01-01

    In this work, high-beta plasma effects are investigated in a low-pressure helicon plasma source attached to a large volume diffusion chamber. When operating above an input power of 900 W and a magnetic field of 30 G a narrow column of bright blue light (due to Ar II radiation) is observed along the axis of the diffusion chamber. With this blue mode, the plasma density is axially very uniform in the diffusion chamber; however, the radial profiles are not, suggesting that a large diamagnetic current might be induced. The diamagnetic behavior of the plasma has been investigated by measuring the temporal evolution of the magnetic field (B z ) and the plasma kinetic pressure when operating in a pulsed discharge mode. It is found that although the electron pressure can exceed the magnetic field pressure by a factor of 2, a complete expulsion of the magnetic field from the plasma interior is not observed. In fact, under our operating conditions with magnetized ions, the maximum diamagnetism observed is ∼2%. It is observed that the magnetic field displays the strongest change at the plasma centre, which corresponds to the maximum in the plasma kinetic pressure. These results suggest that the magnetic field diffuses into the plasma sufficiently quickly that on a long time scale only a slight perturbation of the magnetic field is ever observed

  11. High-frequency heating of plasma with two ion species

    International Nuclear Information System (INIS)

    Klima, R.; Longinov, A.V.; Stepanov, K.N.

    1975-01-01

    The authors consider the penetration of electromagnetic waves with a frequency of the order of the ion cyclotron frequencies and with a fixed longitudinal wave number ksub(long), so that Nsub(long)=ksub(long)c/ω>>1 deep into an inhomogeneous plasma with two ion species. The propagation of two kinds of waves (fast and slow) with widely differing polarization and transverse refraction index is possible. For both types of waves there is an evanescence region at the plasma periphery. The evanescence region is narrow for slow waves and they easily penetrate the plasma. In a dense plasma they become electrostatic and can reach the ion-ion hybrid resonance region. However, the damping of these waves due to Cherenkov interaction with electrons in a high-temperature plasma is strong and therefore they are not suitable for heating plasma of large dimensions, as they are absorbed at the plasma periphery. The fast waves have a wider evanescence region and can be excited effectively only if N 2 is not too high. These waves can be completely absorbed in the plasma (due to Cherenkov interaction with electrons) if xi approximately (v 2 sub(Ti)/v 2 sub(A))Zsub(e)(ωsub(pi)a/c)exp(-Zsub(e) 2 ) > 1, where a is the plasma radius and Zsub(e) = ω/(√2 ksub(long)vsub(Te)). Fast waves can also reach the region where they are transformed into slow waves. In this region their damping increases considerably. It is shown that the transformation region in an inhomogeneous plasma with two ion species in a non-uniform magnetic field may be at the centre of the plasma. Fast waves can be used effectively for heating plasma of large dimensions. (author)

  12. An investigation of pulsed high density plasmas

    International Nuclear Information System (INIS)

    Timmermans, C.J.

    1984-01-01

    In this thesis a wall-stabilized argon cascade arc is studied at values of pulsed pressure up to 14 bar and a pulsed current range up to 2200 A with a time duration of about 2 ms. The basic plasma is a CW cascade arc with a 5 mm diameter plasma column and a length of 90 mm, which operates at a 60 A DC current and at one atmosphere filling pressure. The author starts with an extensive summary of the CW arc investigations. After a brief introduction of the basic transport equations the mass equations of the constituent particles are treated using the extended collisional radiative model. The energy balance equations and the momentum balance are discussed. The electron density is determined from measurements of the continuum radiation. The final chapter contains the experimental results on the electron temperatures and electron densities in the pressure and current pulsed plasma. Attention is given to the deviations from local thermodynamic equilibrium values of the ground level densities of the different argon systems. (Auth.)

  13. High performance deuterium-tritium plasmas in TFTR

    International Nuclear Information System (INIS)

    Sabbagh, S.A.; Bell, M.G.

    1995-03-01

    Plasmas composed of nominally equal concentrations of deuterium and tritium (DT) have been created in TFTR with the goals of producing significant levels of fusion power and of examining the effects of DT fusion alpha particles. Conditioning of the limiter by the injection of lithium pellets has led to an approximate doubling of the energy confinement time, τ E , in supershot plasmas at high plasma current (I p ≤ 2.5 MA) and high heating power (P b ≤ 33 MW). Operation with DT typically results in an additional 20% increase in τ E . In the high poloidal beta, advanced tokamak regime in TFTR, confinement enhancement H triple-bond τ E /τ E ITER-89P > 4 has been obtained in a limiter H-mode configuration at moderate plasma current I p = 0.85 - 1.5 MA. By peaking the plasma current profile, β N dia triple-bond 10 8 tperpendicular > aB 0 /I p = 3 has been obtained in these plasmas, exceeding the β N limit for TFTR plasmas with lower internal inductance, l i . Confinement of alpha particles appears to be classical and losses due to collective effects have not been observed. While small fluctuations in fusion product loss were observed during ELMs, no large loss was detected in DT plasmas

  14. Tritiated bovine fibrinogen labelled in fibrinopeptide A region

    International Nuclear Information System (INIS)

    Wegrzynowicz, Z.; Kloczewiak, M.; Kopec, M.

    1974-01-01

    The method is described for labelling of bovine fibrinogen with 3 H-AcOAc. Preparations labelled at pH 7.8 with 10 to 40 molar excess of 3 H-AcOAc were found to contain 8 to 13 moles of acetyl residues per mole of fibrinogen. The content of clottable protein and UV spectra were unchanged as compared with control unlabelled preprations. The rate of clotting with thrombin was only slightly affected. The investigations on distribution of 3 H in products of proteolysis of 3 H-fibrinogen by thrombin and plasmin demonstrated a preferential labelling of fibrinopeptide A, absence of radioactive tracer in fibrinopeptide B, significantly higher specific radioactivity of fragment E than that of fragment D. Incorporation of the label into fibrinopeptide A opens the possibility for application of 3 H-fibrinogen as a convenient substrate for selective investigations on the enzymatic phase of clotting. (author)

  15. Divertor, thermonuclear device and method of neutralizing high temperature plasma

    International Nuclear Information System (INIS)

    Ikegami, Hideo.

    1995-01-01

    The thermonuclear device comprises a thermonuclear reactor for taking place fusion reactions to emit fusion plasmas, and a divertor made of a hydrogen occluding material, and the divertor is disposed at a position being in contact with the fusion plasmas after nuclear fusion reaction. The divertor is heated by fusion plasmas after nuclear fusion reaction, and hydrogen is released from the hydrogen occluding material as a constituent material. A gas blanket is formed by the released hydrogen to cool and neutralize the supplied high temperature nuclear fusion plasmas. This prevents the high temperature plasmas from hitting against the divertor, elimination of the divertor by melting and evaporation, and solve a problem of processing a divertor activated by neutrons. In addition, it is possible to utilize hydrogen isotopes of fuels effectively and remove unnecessary helium. Inflow of impurities from out of the system can also be prevented. (N.H.)

  16. Antibody functionalized graphene biosensor for label-free electrochemical immunosensing of fibrinogen, an indicator of trauma induced coagulopathy.

    Science.gov (United States)

    Saleem, Waqas; Salinas, Carlos; Watkins, Brian; Garvey, Gavin; Sharma, Anjal C; Ghosh, Ritwik

    2016-12-15

    An antibody, specific to fibrinogen, has been covalently attached to graphene and deposited onto screen printed electrodes using a chitosan hydrogel binder to prepare an inexpensive electrochemical fibrinogen biosensor. Fourier Transform Infrared (FT-IR) spectroscopy has been utilized to confirm the presence of the antibody on the graphene scaffold. Electrochemical Impedance Spectroscopy (EIS) has been utilized to demonstrate that the biosensor responds in a selective manner to fibrinogen in aqueous media even in the presence of plasminogen, a potentially interfering molecule in the coagulopathy cascade. Furthermore, the biosensor was shown to reliably sense fibrinogen in the presence of high background serum albumin levels. Finally, we demonstrated detection of clinically relevant fibrinogen concentrations (938-44,542μg/dL) from human serum and human whole blood samples using this biosensor. This biosensor can potentially be used in a point-of-care device to detect the onset of coagulopathy and monitor response following therapeutic intervention in trauma patients. Thus this biosensor may improve the clinical management of patients with trauma-induced coagulopathy. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Fibrinogen and alpha(1)-antitrypsin in COPD exacerbations

    DEFF Research Database (Denmark)

    Sylvan Ingebrigtsen, Truls; Marott, J. L.; Rode, L.

    2015-01-01

    Background We tested the hypotheses that fibrinogen and alpha(1)-antitrypsin are observationally and genetically associated with exacerbations in COPD. Methods We studied 13 591 individuals with COPD from the Copenhagen General Population Study (2003-2013), of whom 6857 were genotyped for FGB -455...... and exacerbations in instrumental variable analyses. Results Elevated fibrinogen and alpha(1)-antitrypsin levels were associated with increased risk of exacerbations in COPD, HR=1.14 (1.07 to 1.22, p...

  18. To the probe theory in a highly-ionized high-pressure plasma

    International Nuclear Information System (INIS)

    Baksht, F.G.; Rybakov, A.B.

    1997-01-01

    The probe theory in highly-ionized high-pressure plasma is presented. The situation typical for high-pressure plasma, when the plasma in the main part of the near-probe layer is in the state of local ionization equilibrium with general temperature for electrons and heavy particles. Possibility is discussed for determining the parameters of non-perturbed plasma through analysis of the probe characteristic at place of ion saturation, transition area and by the probe floating potential. The experiments were carried out by example of highly-ionized xenon plasma under atmospheric pressure

  19. Plasma characteristics of a high power helicon discharge

    International Nuclear Information System (INIS)

    Ziemba, T; Euripides, P; Slough, J; Winglee, R; Giersch, L; Carscadden, J; Schnackenberg, T; Isley, S

    2006-01-01

    A new high power helicon (HPH) plasma system has been designed to provide input powers of several tens of kilowatts to produce a large area (0.5 m 2 ) of uniform high-density, of at least 5 x 10 17 m -3 , plasma downstream from the helicon coil. Axial and radial plasma characteristics show that the plasma is to a lesser extent created in and near the helicon coil and then is accelerated into the axial and equatorial regions. The bulk acceleration of the plasma is believed to be due to a coupling of the bulk of the electrons to the helicon field, which in turn transfers energy to the ions via ambipolar diffusion. The plasma beta is near unity a few centimetres away from the HPH system and Bdot measurements show ΔB perturbations in the order of the vacuum magnetic field magnitude. In the equatorial region, a magnetic separatrix is seen to develop roughly at the mid-point between the helicon and chamber wall. The magnetic perturbation develops on the time scale of the plasma flow speed and upon the plasma reaching the chamber wall decays to the vacuum magnetic field configuration within 200 μs

  20. Plasma characteristics of a high power helicon discharge

    Energy Technology Data Exchange (ETDEWEB)

    Ziemba, T; Euripides, P; Slough, J; Winglee, R; Giersch, L; Carscadden, J; Schnackenberg, T; Isley, S [Box 351310, University of Washington, Seattle WA, 98195 (United States)

    2006-08-01

    A new high power helicon (HPH) plasma system has been designed to provide input powers of several tens of kilowatts to produce a large area (0.5 m{sup 2}) of uniform high-density, of at least 5 x 10{sup 17} m{sup -3}, plasma downstream from the helicon coil. Axial and radial plasma characteristics show that the plasma is to a lesser extent created in and near the helicon coil and then is accelerated into the axial and equatorial regions. The bulk acceleration of the plasma is believed to be due to a coupling of the bulk of the electrons to the helicon field, which in turn transfers energy to the ions via ambipolar diffusion. The plasma beta is near unity a few centimetres away from the HPH system and Bdot measurements show {delta}B perturbations in the order of the vacuum magnetic field magnitude. In the equatorial region, a magnetic separatrix is seen to develop roughly at the mid-point between the helicon and chamber wall. The magnetic perturbation develops on the time scale of the plasma flow speed and upon the plasma reaching the chamber wall decays to the vacuum magnetic field configuration within 200 {mu}s.

  1. Granulocyte-platelet interactions and platelet fibrinogen receptor exposure

    International Nuclear Information System (INIS)

    Kornecki, E.; Ehrlich, Y.H.; Egbring, R.; Gramse, M.; Seitz, R.; Eckardt, A.; Lukasiewicz, H.; Niewiarowski, S.

    1988-01-01

    The authors have examined the interaction of human granulocyte elastase with human platelets. Incubation of human platelets with human granulocyte elastase exposed active fibrinogen-binding sites as evidenced by 125 I-labeled fibrinogen binding and spontaneous fibrinogen-induced platelet aggregation. The aggregation of platelets by fibrinogen occurred at low concentrations of human granulocyte elastase. Platelets pretreated with human granulocyte elastase exposed an average of 10,500 fibrinogen-binding sites per platelet, i.e., about one-third the number of binding sites exposed by optimal concentrations of ADP. With the use of a polyclonal antiplatelet membrane antibody, the glycoproteins IIb (GPIIb), IIIa (GPIIIa), and a 60,000-Da (60 kDa) protein (66 kDa in a reduced system) derived from GPIIIa were immunoprecipitated from the surface of detergent extracts of human 125 I-radiolabeled platelets pretreated with increasing concentrations of human granulocyte elastase. They conclude that (1) the proteolytic action of human granulocyte elastase on platelet GPIIIa results in the formation of two major hydrolytic products, and (2) human granulocyte elastase exposes active fibrongen-binding sites associated with the GPIIb/GPIIIa complex, resulting in direct platelet aggregation by fibrinogen

  2. Second topical conference on high-temperature plasma diagnostics

    International Nuclear Information System (INIS)

    Jahoda, F.C.; Freese, K.B.

    1978-02-01

    This report contains the program and abstracts of papers presented at the Second American Physical Society Topical Conference on High Temperature Plasma Diagnostics, March 1-3, 1978, Santa Fe, New Mexico

  3. HIGH FREQUENCY ELECTROSTATIC INSTABILITIES IN A PLASMA

    Energy Technology Data Exchange (ETDEWEB)

    Klein, M W; Auer, P L

    1963-06-15

    The dispersion relation is examined for a collisionless infinite plasma in the presence of an anisotropic Maxwellian velocity distribution and a uniform external magnetic field. Unstable solutions exist below the muitiples of the electron cyclotron frequency provided the temperature anisotropy is sufficiently large. The dependence of the growth rate upon harmonic number, density, angle of propagation with respect to the magnetic field, and frequency is discussed for zero as well as non-zero parallel temperatures. In the latter case, the waves are strongly damped as their frequency approaches a multiple of the gyro- frequency. (auth)

  4. High density plasmas formation in Inertial Confinement Fusion and Astrophysics

    International Nuclear Information System (INIS)

    Martinez-Val, J. M.; Minguez, E.; Velarde, P.; Perlado, J. M.; Velarde, G.; Bravo, E.; Eliezer, S.; Florido, R.; Garcia Rubiano, J.; Garcia-Senz, D.; Gil de la Fe, J. M.; Leon, P. T.; Martel, P.; Ogando, F.; Piera, M.; Relano, A.; Rodriguez, R.; Garcia, C.; Gonzalez, E.; Lachaise, M.; Oliva, E.

    2005-01-01

    In inertially confined fusion (ICF), high densities are required to obtain high gains. In Fast Ignition, a high density, low temperature plasma can be obtained during the compression. If the final temperature reached is low enough, the electrons of the plasma can be degenerate. In degenerate plasmas. Bremsstrahlung emission is strongly suppressed an ignition temperature becomes lower than in classical plasmas, which offers a new design window for ICF. The main difficulty of degenerate plasmas in the compression energy needed for high densities. Besides that, the low specific heat of degenerate electrons (as compared to classical values) is also a problem because of the rapid heating of the plasma. Fluid dynamic evolution of supernovae remnants is a very interesting problem in order to predict the thermodynamical conditions achieved in their collision regions. Those conditions have a strong influence in the emission of light and therefore the detection of such events. A laboratory scale system has been designed reproducing the fluid dynamic field in high energy experiments. The evolution of the laboratory system has been calculated with ARWEN code, 2D Radiation CFD that works with Adaptive Mesh Refinement. Results are compared with simulations on the original system obtained with a 3D SPH astrophysical code. New phenomena at the collision plane and scaling of the laboratory magnitudes will be described. Atomic physics for high density plasmas has been studied with participation in experiments to obtain laser produced high density plasmas under NLTE conditions, carried out at LULI. A code, ATOM3R, has been developed which solves rate equations for optically thin plasmas as well as for homogeneous optically thick plasmas making use of escape factors. New improvements in ATOM3R are been done to calculate level populations and opacities for non homogeneous thick plasmas in NLTE, with emphasis in He and H lines for high density plasma diagnosis. Analytical expression

  5. Distinct Adsorption Configurations and Self-Assembly Characteristics of Fibrinogen on Chemically Uniform and Alternating Surfaces including Block Copolymer Nanodomains

    Science.gov (United States)

    2015-01-01

    Understanding protein–surface interactions is crucial to solid-state biomedical applications whose functionality is directly correlated with the precise control of the adsorption configuration, surface packing, loading density, and bioactivity of protein molecules. Because of the small dimensions and highly amphiphilic nature of proteins, investigation of protein adsorption performed on nanoscale topology can shed light on subprotein-level interaction preferences. In this study, we examine the adsorption and assembly behavior of a highly elongated protein, fibrinogen, on both chemically uniform (as-is and buffered HF-treated SiO2/Si, and homopolymers of polystyrene and poly(methyl methacrylate)) and varying (polystyrene-block-poly(methyl methacrylate)) surfaces. By focusing on high-resolution imaging of individual protein molecules whose configurations are influenced by protein–surface rather than protein–protein interactions, fibrinogen conformations characteristic to each surface are identified and statistically analyzed for structural similarities/differences in key protein domains. By exploiting block copolymer nanodomains whose repeat distance is commensurate with the length of the individual protein, we determine that fibrinogen exhibits a more neutral tendency for interaction with both polystyrene and poly(methyl methacrylate) blocks relative to the case of common globular proteins. Factors affecting fibrinogen–polymer interactions are discussed in terms of hydrophobic and electrostatic interactions. In addition, assembly and packing attributes of fibrinogen are determined at different loading conditions. Primary orientations of fibrinogen and its rearrangements with respect to the underlying diblock nanodomains associated with different surface coverage are explained by pertinent protein interaction mechanisms. On the basis of two-dimensional stacking behavior, a protein assembly model is proposed for the formation of an extended fibrinogen network

  6. Engaging high school students as plasma science outreach ambassadors

    Science.gov (United States)

    Wendt, Amy; Boffard, John

    2017-10-01

    Exposure to plasma science among future scientists and engineers is haphazard. In the U.S., plasma science is rare (or absent) in mainstream high school and introductory college physics curricula. As a result, talented students may be drawn to other careers simply due to a lack of awareness of the stimulating science and wide array of fulfilling career opportunities involving plasmas. In the interest of enabling informed decisions about career options, we have initiated an outreach collaboration with the Madison West High School Rocket Club. Rocket Club members regularly exhibit their activities at public venues, including large-scale expos that draw large audiences of all ages. Building on their historical emphasis on small scale rockets with chemical motors, we worked with the group to add a new feature to their exhibit that highlights plasma-based spacecraft propulsion for interplanetary probes. This new exhibit includes a model satellite with a working (low power) plasma thruster. The participating high school students led the development process, to be described, and enthusiastically learned to articulate concepts related to plasma thruster operation and to compare the relative advantages of chemical vs. plasma/electrical propulsion systems for different scenarios. Supported by NSF Grant PHY-1617602.

  7. [High plasma folate in patients with phenylketonuria].

    Science.gov (United States)

    Zielińska, Magdalena; Żółkowska, Joanna; Przybylska-Kruszewska, Amanda; Gładysz, Dominika; Korycińska-Chaaban, Dorota; Nowacka, Maria; Hozyasz, Kamil K

    2016-04-01

    Phenylketonuria is an inborn error of metabolism treated with a closely monitored low phenylalanine diet. Protein substitutes used for treatment are supplemented with vitamins and micronutrients. The aim of this study was to investigate plasma folic acid concentrations in children with phenylketonuria. Retrospective analysis of medical records of 73 patients with phenylketonuria and 28 with mild hyperphenylalaninemia (on normal diet) was carried out. Intake of folic acid was calculated on the basis of protein substitute intake. Folate concentrations were analyzed according to their intake, and concentration of homocysteine and phenylalanine. In 76.7% patients with phenylketonuria intake of folic acid exceeded recommended dietary allowance. Serum folic acid concentrations above upper reference level were detected in 75.3% patients with phenylketonuria and only in 25% patients with hyperphenylalaninemia (pphenylketonuria requires further detailed research. © 2016 MEDPRESS.

  8. Plasma Photonic Devices for High Energy Density Science

    International Nuclear Information System (INIS)

    Kodama, R.

    2005-01-01

    High power laser technologies are opening a variety of attractive fields of science and technology using high energy density plasmas such as plasma physics, laboratory astrophysics, material science, nuclear science including medical applications and laser fusion. The critical issues in the applications are attributed to the control of intense light and enormous density of charged particles including efficient generation of the particles such as MeV electrons and protons with a current density of TA/cm2. Now these application possibilities are limited only by the laser technology. These applications have been limited in the control of the high power laser technologies and their optics. However, if we have another device consisted of the 4th material, i.e. plasma, we will obtain a higher energy density condition and explore the application possibilities, which could be called high energy plasma device. One of the most attractive devices has been demonstrated in the fast ignition scheme of the laser fusion, which is cone-guiding of ultra-intense laser light in to high density regions1. This is one of the applications of the plasma device to control the ultra-intense laser light. The other role of the devices consisted of transient plasmas is control of enormous energy-density particles in a fashion analogous to light control with a conventional optical device. A plasma fibre (5?m/1mm), as one example of the devices, has guided and deflected the high-density MeV electrons generated by ultra-intense laser light 2. The electrons have been well collimated with either a lens-like plasma device or a fibre-like plasma, resulting in isochoric heating and creation of ultra-high pressures such as Giga bar with an order of 100J. Plasmas would be uniquely a device to easily control the higher energy density particles like a conventional optical device as well as the ultra-intense laser light, which could be called plasma photonic device. (Author)

  9. Physics of high performance deuterium-tritium plasmas in TFTR

    International Nuclear Information System (INIS)

    McGuire, K.M.; Batha, S.

    1996-11-01

    During the past two years, deuterium-tritium (D-T) plasmas in the Tokamak Fusion Test Reactor (TFTR) have been used to study fusion power production, isotope effects associated with tritium fueling, and alpha-particle physics in several operational regimes. The peak fusion power has been increased to 10.7 MW in the supershot mode through the use of increased plasma current and toroidal magnetic field and extensive lithium wall conditioning. The high-internal-inductance (high-I i ) regime in TFTR has been extended in plasma current and has achieved 8.7 MW of fusion power. Studies of the effects of tritium on confinement have now been carried out in ohmic, NBI- and ICRF- heated L-mode and reversed-shear plasmas. In general, there is an enhancement in confinement time in D-T plasmas which is most pronounced in supershot and high-I i discharges, weaker in L-mode plasmas with NBI and ICRF heating and smaller still in ohmic plasmas. In reversed-shear discharges with sufficient deuterium-NBI heating power, internal transport barriers have been observed to form, leading to enhanced confinement. Large decreases in the ion heat conductivity and particle transport are inferred within the transport barrier. It appears that higher heating power is required to trigger the formation of a transport barrier with D-T NBI and the isotope effect on energy confinement is nearly absent in these enhanced reverse-shear plasmas. Many alpha-particle physics issues have been studied in the various operating regimes including confinement of the alpha particles, their redistribution by sawteeth, and their loss due to MHD instabilities with low toroidal mode numbers. In weak-shear plasmas, alpha-particle destabilization of a toroidal Alfven eigenmode has been observed

  10. Interaction of High Intensity Electromagnetic Waves with Plasmas: Final Report

    International Nuclear Information System (INIS)

    Shvets, G.

    2008-01-01

    The focus of our work during the duration of this grant was on the following areas: (a) the fundamental plasma physics of intense laser-plasma interactions, including the nonlinear excitation of plasma waves for accelerator applications, as well as the recently discovered by us phenomenon of the relativistic bi-stability of relativistic plasma waves driven by a laser beatwave; (b) interaction of high power microwave beams with magnetized plasma, including some of the recently discovered by us phenomena such as the Undulator Induced Transparency (UIT) as well as the new approaches to dynamic manipulation of microwave pulses; (c) investigations of the multi-color laser pulse interactions in the plasma, including the recently discovered by us phenomenon of Electromagnetic Cascading (EC) and the effect of the EC of three-dimensional dynamics of laser pulses (enhanced/suppressed selffocusing etc.); (d) interaction of high-current electron beams with the ambient plasma in the context of Fast Ignitor (FI) physics, with the emphasis on the nonlinear dynamics of the Weibel instability and beam filamentation.

  11. Electromagnetic-implosion generation of pulsed high energy density plasma

    International Nuclear Information System (INIS)

    Baker, W.L.; Broderick, N.F.; Degnan, J.H.; Hussey, T.W.; Kiuttu, G.F.; Kloc, D.A.; Reinovsky, R.E.

    1983-01-01

    This chapter reports on the experimental and theoretical investigation of the generation of pulsed high-energy-density plasmas by electromagnetic implosion of cylindrical foils (i.e., imploding liners or hollow Z-pinches) at the Air Force Weapons Laboratory. Presents a comparison of experimental data with one-dimensional MHD and two-dimensional calculations. Points out that the study is distinct from other imploding liner efforts in that the approach is to produce a hot, dense plasma from the imploded liner itself, rather than to compress a magnetic-field-performed plasma mixture. The goal is to produce an intense laboratory pulsed X-ray source

  12. High resolution X-ray spectroscopy of thermal plasmas

    International Nuclear Information System (INIS)

    Canizares, C.R.

    1990-01-01

    This paper concentrates on reviewing highlights of the Focal Plane Crystal Spectrometer (FPCS) results on thermal plasmas, particularly supernova remnants (SNRs) and clusters of galaxies from the Einstein observatory. During Einstein's short but happy life, we made over 400 observations with the FPCS of 40 different objects. Three quarters of these were objects in which the emission was primarily from optically thin thermal plasma, primarily supernova remnants (SNRs) and clusters of galaxies. Thermal plasmas provide an excellent illustration of how spectral data, particularly high resolution spectral data, can be an important tool for probing the physical properties of astrophysical objects. (author)

  13. Acetylation and glycation of fibrinogen in vitro occur at specific lysine residues in a concentration dependent manner: A mass spectrometric and isotope labeling study

    International Nuclear Information System (INIS)

    Svensson, Jan; Bergman, Ann-Charlotte; Adamson, Ulf; Blombäck, Margareta; Wallén, Håkan; Jörneskog, Gun

    2012-01-01

    Highlights: ► Fibrinogen was incubated in vitro with glucose or aspirin. ► Acetylations and glycations were found at twelve lysine sites by mass spectrometry. ► The labeling by aspirin and glucose occurred dose-dependently. ► No competition between glucose and aspirin for binding to fibrinogen was found. -- Abstract: Aspirin may exert part of its antithrombotic effects through platelet-independent mechanisms. Diabetes is a condition in which the beneficial effects of aspirin are less prominent or absent – a phenomenon called “aspirin resistance”. We investigated whether acetylation and glycation occur at specific sites in fibrinogen and if competition between glucose and aspirin in binding to fibrinogen occurs. Our hypothesis was that such competition might be one explanation to “aspirin resistance” in diabetes. After incubation of fibrinogen in vitro with aspirin (0.8 mM, 24 h) or glucose (100 mM, 5–10 days), we found 12 modified sites with mass spectrometric techniques. Acetylations in the α-chain: αK191, αK208, αK224, αK429, αK457, αK539, αK562, in the β-chain: βK233, and in the γ-chain: γK170 and γK273. Glycations were found at βK133 and γK75, alternatively γK85. Notably, the lysine 539 is a site involved in FXIII-mediated cross-linking of fibrin. With isotope labeling in vitro, using [ 14 C-acetyl]salicylic acid and [ 14 C]glucose, a labeling of 0.013–0.084 and 0.12–0.5 mol of acetylated and glycated adduct/mol fibrinogen, respectively, was found for clinically (12.9–100 μM aspirin) and physiologically (2–8 mM glucose) relevant plasma concentrations. No competition between acetylation and glycation could be demonstrated. Thus, fibrinogen is acetylated at several lysine residues, some of which are involved in the cross-linking of fibrinogen. This may mechanistically explain why aspirin facilitates fibrin degradation. We find no support for the idea that glycation of fibrin(ogen) interferes with acetylation of

  14. Acetylation and glycation of fibrinogen in vitro occur at specific lysine residues in a concentration dependent manner: A mass spectrometric and isotope labeling study

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Jan, E-mail: jan.svensson@ki.se [Department of Molecular Medicine and Surgery, Karolinska Institutet, Karolinska University Hospital (Solna), SE-171 76 Stockholm (Sweden); Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, SE-182 88 Stockholm (Sweden); Bergman, Ann-Charlotte [Department of Molecular Medicine and Surgery, Karolinska Institutet, Karolinska University Hospital (Solna), SE-171 76 Stockholm (Sweden); Adamson, Ulf [Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, SE-182 88 Stockholm (Sweden); Blombaeck, Margareta [Department of Molecular Medicine and Surgery, Karolinska Institutet, Karolinska University Hospital (Solna), SE-171 76 Stockholm (Sweden); Wallen, Hakan; Joerneskog, Gun [Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, SE-182 88 Stockholm (Sweden)

    2012-05-04

    Highlights: Black-Right-Pointing-Pointer Fibrinogen was incubated in vitro with glucose or aspirin. Black-Right-Pointing-Pointer Acetylations and glycations were found at twelve lysine sites by mass spectrometry. Black-Right-Pointing-Pointer The labeling by aspirin and glucose occurred dose-dependently. Black-Right-Pointing-Pointer No competition between glucose and aspirin for binding to fibrinogen was found. -- Abstract: Aspirin may exert part of its antithrombotic effects through platelet-independent mechanisms. Diabetes is a condition in which the beneficial effects of aspirin are less prominent or absent - a phenomenon called 'aspirin resistance'. We investigated whether acetylation and glycation occur at specific sites in fibrinogen and if competition between glucose and aspirin in binding to fibrinogen occurs. Our hypothesis was that such competition might be one explanation to 'aspirin resistance' in diabetes. After incubation of fibrinogen in vitro with aspirin (0.8 mM, 24 h) or glucose (100 mM, 5-10 days), we found 12 modified sites with mass spectrometric techniques. Acetylations in the {alpha}-chain: {alpha}K191, {alpha}K208, {alpha}K224, {alpha}K429, {alpha}K457, {alpha}K539, {alpha}K562, in the {beta}-chain: {beta}K233, and in the {gamma}-chain: {gamma}K170 and {gamma}K273. Glycations were found at {beta}K133 and {gamma}K75, alternatively {gamma}K85. Notably, the lysine 539 is a site involved in FXIII-mediated cross-linking of fibrin. With isotope labeling in vitro, using [{sup 14}C-acetyl]salicylic acid and [{sup 14}C]glucose, a labeling of 0.013-0.084 and 0.12-0.5 mol of acetylated and glycated adduct/mol fibrinogen, respectively, was found for clinically (12.9-100 {mu}M aspirin) and physiologically (2-8 mM glucose) relevant plasma concentrations. No competition between acetylation and glycation could be demonstrated. Thus, fibrinogen is acetylated at several lysine residues, some of which are involved in the cross-linking of

  15. The mechanical properties of dry, electrospun fibrinogen fibers

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Stephen; Sigley, Justin; Helms, Christine C. [Department of Physics, Wake Forest University, Winston-Salem, NC 27109 (United States); Stitzel, Joel [Department of Biomedical Engineering, Wake Forest University Health Sciences, Winston-Salem, NC, 27157 (United States); Berry, Joel; Bonin, Keith [Department of Physics, Wake Forest University, Winston-Salem, NC 27109 (United States); Guthold, Martin, E-mail: gutholdm@wfu.edu [Department of Physics, Wake Forest University, Winston-Salem, NC 27109 (United States)

    2012-02-01

    Due to their low immunogenicity, biodegradability and native cell-binding domains, fibrinogen fibers may be good candidates for tissue engineering scaffolds, drug delivery vehicles and other medical devices. We used a combined atomic force microscope (AFM)/optical microscope technique to study the mechanical properties of individual, electrospun fibrinogen fibers in dry, ambient conditions. The AFM was used to stretch individual fibers suspended over 13.5 {mu}m wide grooves in a transparent substrate. The optical microscope, located below the sample, was used to monitor the stretching process. Electrospun fibrinogen fibers (diameter, 30-200 nm) can stretch to 74% beyond their original length before rupturing at a stress of 2.1 GPa. They can stretch elastically up to 15% beyond their original length. Using incremental stress-strain curves the viscoelastic behavior of these fibers was determined. The total stretch modulus was 4.2 GPa while the relaxed elastic modulus was 3.7 GPa. When held at constant strain, fibrinogen fibers display stress relaxation with a fast and slow relaxation time of 1.2 s and 11 s. In comparison to native and electrospun collagen fibers, dry electrospun fibrinogen fibers are significantly more extensible and elastic. In comparison to wet electrospun fibrinogen fibers, dry fibers are about 1000 times stiffer. - Highlights: Black-Right-Pointing-Pointer Fabricated dry, electrospun, fibrinogen fibers; average diameter, D{sub avg.} = 95 nm. Black-Right-Pointing-Pointer Determined mechanical properties with combined atomic force/optical microscope. Black-Right-Pointing-Pointer Fibers are very extensible ({epsilon}{sub max} = 74%) and elastic ({epsilon}{sub elastic} = 15%). Black-Right-Pointing-Pointer Fiber total modulus, E{sub tot.} = 4.2 GPa; elastic modulus, E{sub el.} = 3.7 GPa. Black-Right-Pointing-Pointer Fiber stress relaxation times: {tau}{sub 1} = 1.2 s and {tau}{sub 2} = 11 s.

  16. The mechanical properties of dry, electrospun fibrinogen fibers

    International Nuclear Information System (INIS)

    Baker, Stephen; Sigley, Justin; Helms, Christine C.; Stitzel, Joel; Berry, Joel; Bonin, Keith; Guthold, Martin

    2012-01-01

    Due to their low immunogenicity, biodegradability and native cell-binding domains, fibrinogen fibers may be good candidates for tissue engineering scaffolds, drug delivery vehicles and other medical devices. We used a combined atomic force microscope (AFM)/optical microscope technique to study the mechanical properties of individual, electrospun fibrinogen fibers in dry, ambient conditions. The AFM was used to stretch individual fibers suspended over 13.5 μm wide grooves in a transparent substrate. The optical microscope, located below the sample, was used to monitor the stretching process. Electrospun fibrinogen fibers (diameter, 30–200 nm) can stretch to 74% beyond their original length before rupturing at a stress of 2.1 GPa. They can stretch elastically up to 15% beyond their original length. Using incremental stress–strain curves the viscoelastic behavior of these fibers was determined. The total stretch modulus was 4.2 GPa while the relaxed elastic modulus was 3.7 GPa. When held at constant strain, fibrinogen fibers display stress relaxation with a fast and slow relaxation time of 1.2 s and 11 s. In comparison to native and electrospun collagen fibers, dry electrospun fibrinogen fibers are significantly more extensible and elastic. In comparison to wet electrospun fibrinogen fibers, dry fibers are about 1000 times stiffer. - Highlights: ► Fabricated dry, electrospun, fibrinogen fibers; average diameter, D avg. = 95 nm. ► Determined mechanical properties with combined atomic force/optical microscope. ► Fibers are very extensible (ε max = 74%) and elastic (ε elastic = 15%). ► Fiber total modulus, E tot. = 4.2 GPa; elastic modulus, E el. = 3.7 GPa. ► Fiber stress relaxation times: τ 1 = 1.2 s and τ 2 = 11 s.

  17. Topics in high-intensity laser plasma interaction

    International Nuclear Information System (INIS)

    Leemans, W.P.

    1991-01-01

    The interaction of high intensity laser pulses with pre-formed and laser-produced plasmas is studied. Through experiments and simulations we have investigated stimulated Compton scattering in preformed plasmas and the plasma physics aspects of tunnel-ionized gases. A theoretical study is presented on the nonlinear dynamics of relativistic plasma waves driven by colinear optical mixing. The electron density-fluctuation spectra induced by stimulated Compton scattering have been directly observed for the first time. A CO2 laser was focused into pre-formed plasmas with densities n(e) varied from 0.4-6 x 10(exp 16) cu cm. The fluctuations corresponding to backscatter were probed using Thomson scattering. At low n(e), the scattered spectra peak at a frequency shift Delta omega is approximately kv e and appears to be in a linear regime. At the highest n(e), a nonlinear saturation of the SCS instability is observed due to a self-induced perturbation of the electron distribution function. Tunnel-ionized plasmas have been studied through experiments and particle simulations. Experimentally, qualitative evidence for plasma temperature control by varying the laser polarization was obtained by the measurement of stimulated Compton scattering fluctuation spectra and x-ray emission from such plasmas. A higher parallel temperature than expected from the single-particle tunneling model was observed. Simulations indicate that stochastic heating and the Weibel instability play an important role in plasma heating in all directions and isotropization. The non-linear dynamics associated with beatwave (Delta omega, Delta k) excited long wavelength plasma waves in the presence of strong, short wavelength density ripple have been examined, using the relativistic Lagrangian oscillator model. This model shows period doubling that roughly follows Feigenbaum scaling, and a transition to chaos

  18. Edge density profiles in high-performance JET plasmas

    International Nuclear Information System (INIS)

    Summers, D.D.R.; Viaccoz, B.; Vince, J.

    1997-01-01

    Detailed electron density profiles of the scrape-off layer in high-performance JET plasmas (plasma current, I p nbi ∝17 MW) have been measured by means of a lithium beam diagnostic system featuring high spatial resolution [Kadota (1978)[. Measurements were taken over a period of several seconds, allowing examination of the evolution of the edge profile at a location upstream from the divertor target. The data clearly show the effects of the H-mode transition - an increase in density near the plasma separatrix and a reduction in density scrape-off length. The profiles obtained under various plasma conditions are compared firstly with data from other diagnostics, located elsewhere in the vessel, and also with the predictions of an 'onion-skin' model (DIVIMP), which used, as initial parameters, data from an array of probes located in the divertor target. (orig.)

  19. High-fidelity plasma codes for burn physics

    Energy Technology Data Exchange (ETDEWEB)

    Cooley, James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Graziani, Frank [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Marinak, Marty [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Murillo, Michael [Michigan State Univ., East Lansing, MI (United States)

    2016-10-19

    Accurate predictions of equation of state (EOS), ionic and electronic transport properties are of critical importance for high-energy-density plasma science. Transport coefficients inform radiation-hydrodynamic codes and impact diagnostic interpretation, which in turn impacts our understanding of the development of instabilities, the overall energy balance of burning plasmas, and the efficacy of self-heating from charged-particle stopping. Important processes include thermal and electrical conduction, electron-ion coupling, inter-diffusion, ion viscosity, and charged particle stopping. However, uncertainties in these coefficients are not well established. Fundamental plasma science codes, also called high-fidelity plasma codes, are a relatively recent computational tool that augments both experimental data and theoretical foundations of transport coefficients. This paper addresses the current status of HFPC codes and their future development, and the potential impact they play in improving the predictive capability of the multi-physics hydrodynamic codes used in HED design.

  20. Characteristics of MHD stability of high beta plasmas in LHD

    International Nuclear Information System (INIS)

    Sato, M.; Nakajima, N.; Watanabe, K.Y.; Todo, Y.; Suzuki, Y.

    2012-11-01

    In order to understand characteristics of the MHD stability of high beta plasmas obtained in the LHD experiments, full MHD simulations have been performed for the first time. Since there is a magnetic hill in a plasma peripheral region, the ballooning modes extending into the plasma peripheral region with a chaotic magnetic field are destabilized. However, in the nonlinear phase, the core region comes under the in influence of the instabilities and the central pressure decreases. There is a tendency that modes are suppressed as the beta value and/or magnetic Reynolds number increase, which is consistent with a result that high beta plasmas enter the second stable region of the ideal ballooning modes as beta increases and remaining destabilized ballooning modes are considered to be resistive type. (author)

  1. High efficiency nebulization for helium inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Jorabchi, Kaveh; McCormick, Ryan; Levine, Jonathan A.; Liu Huiying; Nam, S.-H.; Montaser, Akbar

    2006-01-01

    A pneumatically-driven, high efficiency nebulizer is explored for helium inductively coupled plasma mass spectrometry. The aerosol characteristics and analyte transport efficiencies of the high efficiency nebulizer for nebulization with helium are measured and compared to the results obtained with argon. Analytical performance indices of the helium inductively coupled plasma mass spectrometry are evaluated in terms of detection limits and precision. The helium inductively coupled plasma mass spectrometry detection limits obtained with the high efficiency nebulizer at 200 μL/min are higher than those achieved with the ultrasonic nebulizer consuming 2 mL/min solution, however, precision is generally better with high efficiency nebulizer (1-4% vs. 3-8% with ultrasonic nebulizer). Detection limits with the high efficiency nebulizer at 200 μL/min solution uptake rate approach those using ultrasonic nebulizer upon efficient desolvation with a heated spray chamber followed by a Peltier-cooled multipass condenser

  2. High energy density Z-pinch plasmas using flow stabilization

    Energy Technology Data Exchange (ETDEWEB)

    Shumlak, U., E-mail: shumlak@uw.edu; Golingo, R. P., E-mail: shumlak@uw.edu; Nelson, B. A., E-mail: shumlak@uw.edu; Bowers, C. A., E-mail: shumlak@uw.edu; Doty, S. A., E-mail: shumlak@uw.edu; Forbes, E. G., E-mail: shumlak@uw.edu; Hughes, M. C., E-mail: shumlak@uw.edu; Kim, B., E-mail: shumlak@uw.edu; Knecht, S. D., E-mail: shumlak@uw.edu; Lambert, K. K., E-mail: shumlak@uw.edu; Lowrie, W., E-mail: shumlak@uw.edu; Ross, M. P., E-mail: shumlak@uw.edu; Weed, J. R., E-mail: shumlak@uw.edu [Aerospace and Energetics Research Program, University of Washington, Seattle, Washington, 98195-2250 (United States)

    2014-12-15

    The ZaP Flow Z-Pinch research project[1] at the University of Washington investigates the effect of sheared flows on MHD instabilities. Axially flowing Z-pinch plasmas are produced that are 100 cm long with a 1 cm radius. The plasma remains quiescent for many radial Alfvén times and axial flow times. The quiescent periods are characterized by low magnetic mode activity measured at several locations along the plasma column and by stationary visible plasma emission. Plasma evolution is modeled with high-resolution simulation codes – Mach2, WARPX, NIMROD, and HiFi. Plasma flow profiles are experimentally measured with a multi-chord ion Doppler spectrometer. A sheared flow profile is observed to be coincident with the quiescent period, and is consistent with classical plasma viscosity. Equilibrium is determined by diagnostic measurements: interferometry for density; spectroscopy for ion temperature, plasma flow, and density[2]; Thomson scattering for electron temperature; Zeeman splitting for internal magnetic field measurements[3]; and fast framing photography for global structure. Wall stabilization has been investigated computationally and experimentally by removing 70% of the surrounding conducting wall to demonstrate no change in stability behavior.[4] Experimental evidence suggests that the plasma lifetime is only limited by plasma supply and current waveform. The flow Z-pinch concept provides an approach to achieve high energy density plasmas,[5] which are large, easy to diagnose, and persist for extended durations. A new experiment, ZaP-HD, has been built to investigate this approach by separating the flow Z-pinch formation from the radial compression using a triaxial-electrode configuration. This innovation allows more detailed investigations of the sheared flow stabilizing effect, and it allows compression to much higher densities than previously achieved on ZaP by reducing the linear density and increasing the pinch current. Experimental results and

  3. Downstream plasma transport and metal ionization in a high-powered pulsed-plasma magnetron

    International Nuclear Information System (INIS)

    Meng, Liang; Szott, Matthew M.; McLain, Jake T.; Ruzic, David N.; Yu, He

    2014-01-01

    Downstream plasma transport and ionization processes in a high-powered pulsed-plasma magnetron were studied. The temporal evolution and spatial distribution of electron density (n e ) and temperature (T e ) were characterized with a 3D scanning triple Langmuir probe. Plasma expanded from the racetrack region into the downstream region, where a high n e peak was formed some time into the pulse-off period. The expansion speed and directionality towards the substrate increased with a stronger magnetic field (B), largely as a consequence of a larger potential drop in the bulk plasma region during a relatively slower sheath formation. The fraction of Cu ions in the deposition flux was measured on the substrate using a gridded energy analyzer. It increased with higher pulse voltage. With increased B field from 200 to 800 Gauss above racetrack, n e increased but the Cu ion fraction decreased from 42% to 16%. A comprehensive model was built, including the diffusion of as-sputtered Cu flux, the Cu ionization in the entire plasma region using the mapped n e and T e data, and ion extraction efficiency based on the measured plasma potential (V p ) distribution. The calculations matched the measurements and indicated the main causes of lower Cu ion fractions in stronger B fields to be the lower T e and inefficient ion extraction in a larger pre-sheath potential.

  4. Cushing`s disease: Fibrinogen and D-dimer levels fail to normalize despite early postoperative remission - a prospective, controlled study.

    Science.gov (United States)

    Witek, Przemysław; Zieliński, Grzegorz; Szamotulska, Katarzyna; Witek, Joanna; Kamiński, Grzegorz

    2016-01-01

    Effective transsphenoidal surgery (TSS) for Cushing`s disease (CD) normalizes cortisol levels and reduces complications of hypercortisolism. However, there is evidence of increased cardiovascular morbidity even after successful surgery. A prospective, controlled study on the dynamics of fibrinogen and D-dimer levels with a six-month follow-up after an effective TSS for CD. Forty patients with CD and forty healthy age- and sex-matched subjects were included. We assessed ACTH, urinary and serum cortisol, and fibrinogen and D-dimer levels before TSS and during follow-up. Baseline BMI (P < 0.001), fibrinogen (P = 0.002), and D-dimer (P = 0.001) levels in CD patients were significantly higher than those in healthy controls. High fibrinogen levels in the CD group were independent of BMI, and were positively associated with hsCRP (rS = 0.61, P < 0.001) and arterial hypertension (P = 0.029). After the six-month follow-up we confirmed a sustained difference between the remission group and controls in fibrinogen and D-dimer levels (P = 0.001 and P = 0.017, respectively). Despite early biochemical remission of CD the levels of fibrinogen and D-dimer failed to decrease. This probably contributes to the high risk of thrombotic events and indicates the need for a close follow-up for signs of thromboembolic and cardiovascular complications in patients with early CD remission. (Endokrynol Pol 2016; 67 (3): 283-291).

  5. Control and metrology of high harmonic generation on plasma mirrors

    International Nuclear Information System (INIS)

    Monchoce, Sylvain

    2014-01-01

    When an ultra intense femtosecond laser with high contrast is focused on a solid target, the laser field at focus is sufficient enough to completely ionize the target surface during the rising edge of the laser pulse and form a plasma. This dense plasma entirely reflects the incident beam in the specular direction: this is a so-called plasma mirror. As the interaction between the laser and the plasma mirror is highly non-linear, it thus leads to the high harmonic generation (HHG) in the reflected beam. In the temporal domain, this harmonic spectrum is associated to a train of atto-second pulses. The aim of my PhD were to experimentally control this HHG and to measure the properties of the harmonics. We first studied the optimization of the harmonic signal, and then the spatial characterization of the harmonic beam in the far-field (harmonic divergence). These characterizations are not only important to develop an intense XUV/atto-second light source, but also to get a better understanding of the laser-matter interaction at very high intensity. We have thus been able to get crucial information of the electrons and ions dynamics of the plasma, showing that the harmonics can also be used as a diagnostic of the laser-plasma interaction. We then developed a new general approach for optically-controlled spatial structuring of overdense plasmas generated at the surface of initially plain solid targets. We demonstrate it experimentally by creating sinusoidal plasma gratings of adjustable spatial periodicity and depth, and study the interaction of these transient structures with an ultra-intense laser pulse to establish their usability at relativistically high intensities. We then show how these gratings can be used as a 'spatial ruler' to determine the source size of the high-order harmonic beams produced at the surface of an overdense plasma. These results open new directions both for the metrology of laser-plasma interactions and the emerging field of ultrahigh

  6. Electrospun nanofibre fibrinogen for urinary tract tissue reconstruction

    International Nuclear Information System (INIS)

    McManus, Michael; Boland, Eugene; Sell, Scott; Bowen, Whitney; Koo, Harry; Simpson, David; Bowlin, Gary

    2007-01-01

    The purpose of this study was to demonstrate that human bladder smooth muscle cells (HBSM) remodel electrospun fibrinogen mats. Fibrinogen scaffolds were electrospun and disinfected using standard methods. Scaffolds were seeded with 5 x 10 4 HBSM per scaffold. Cultures were supplemented with aprotinin concentrations of 0 KIU ml -1 (no aprotinin), 100 KIU ml -1 or 1000 KIU ml -1 and incubated with twice weekly media changes. Samples were removed for evaluation at 1, 3, 7 and 14 days. Cultured scaffolds were evaluated with a WST-1 cell proliferation assay, scanning electron microscopy and histology. Cell culture demonstrated that HBSM readily migrated into and initiated remodelling of the electrospun fibrinogen scaffolds by deposition of collagen. Proliferation was suppressed during this initial phase with respect to a 2D control due to cell migration. Histology confirmed that proliferation increased during the later stages of remodelling. Remodelling was slower at higher aprotinin concentrations. These results demonstrate that HBSM rapidly remodel an electrospun fibrinogen scaffold and deposit native collagen. The process can be modulated using aprotinin, a protease inhibitor. These initial findings indicate that there is tremendous potential for electrospun fibrinogen as a urologic tissue engineering scaffold with the ultimate goal of producing an implantable acellular product that would promote cellular in-growth and in situ tissue regeneration

  7. High resolution X-ray spectroscopy of laser generated plasmas

    International Nuclear Information System (INIS)

    Faenov, A.Ya.; Skobelev, I.Yu.; Rosmej, F.B.

    1999-01-01

    The application of recently developed spectroscopic instruments in laser produced plasmas with simultaneous high spectral and spatial resolution combined with high luminosity discovered new types of X-ray spectra. These new types are characterised by the disappearance of the resonance lines and the strong emission of dielectronic satellite spectra. Several types of transitions of highly charged ions are discovered which are unknown from usual sources employed in atomic physics. New theoretical models are developed and successfully applied for the interpretation and for plasma diagnostics. (orig.)

  8. High resolution X-ray spectroscopy of laser generated plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Faenov, A.Ya.; Skobelev, I.Yu. [Multicharged Ions Spectra Data Center of VNIIFTRI, Mendeleevo (Russian Federation); Rosmej, F.B. [Technische Hochschule Darmstadt (Germany). Inst. fuer Kernphysik

    1999-11-01

    The application of recently developed spectroscopic instruments in laser produced plasmas with simultaneous high spectral and spatial resolution combined with high luminosity discovered new types of X-ray spectra. These new types are characterised by the disappearance of the resonance lines and the strong emission of dielectronic satellite spectra. Several types of transitions of highly charged ions are discovered which are unknown from usual sources employed in atomic physics. New theoretical models are developed and successfully applied for the interpretation and for plasma diagnostics. (orig.) 28 refs.

  9. Anomalous high-frequency resistivity of a plasma

    International Nuclear Information System (INIS)

    Kruer, W.L.; Dawson, J.M.

    1971-06-01

    In one- and two-dimensional computer simulations we investigate anomalous high-frequency resistivity in a plasma driven by a large electric field oscillating near the electron plasma frequency. The large field excites the oscillating two-stream and the ion-acoustic decay instabilities in agreement with the linear theory. When the ion and electron fluctuations saturate, a strong anomalous heating of the plasma sets in. This strong heating is due to an efficient coupling of the externally imposed large electric field to the plasma by ion fluctuations. We determine the anomalous collision frequency and the saturation fluctuation amplitudes as a function of the external field amplitude and frequency, and the electron-ion mass ratio. A simple nonlinear theory gives results in reasonable agreement with simulations. 24 refs., 10 figs

  10. High frequency parametric wave phenomena and plasma heating: a review

    International Nuclear Information System (INIS)

    Porkolab, M.

    1975-11-01

    A survey of parametric instabilities in plasma, and associated particle heating, is presented. A brief summary of linear theory is given. The physical mechanism of decay instability, the purely growing mode (oscillating two-stream instability) and soliton and density cavity formation is presented. Effects of density gradients are discussed. Possible nonlinear saturation mechanisms are pointed out. Experimental evidence for the existence of parametric instabilities in both unmagnetized and magnetized plasmas is reviewed in some detail. Experimental observation of plasma heating associated with the presence of parametric instabilities is demonstrated by a number of examples. Possible application of these phenomena to heating of pellets by lasers and heating of magnetically confined fusion plasmas by high power microwave sources is discussed

  11. The down-regulation of the mitogenic fibrinogen receptor (MFR) in serum-containing medium does not occur in defined medium.

    Science.gov (United States)

    Levesque, J P; Hatzfeld, A; Domart, I; Hatzfeld, J

    1990-02-01

    Normal human hemopoietic cells such as early bone marrow progenitors, or lymphoma-derived cell lines such as Raji or JM cells, possess a low-affinity receptor specific for fibrinogen. This receptor triggers a mitogenic effect. It differs from the glycoprotein IIb-IIIa which is involved in fibrinogen-induced platelet aggregation. We demonstrate here that this mitogenic fibrinogen receptor (MFR) can be internalized or reexpressed, depending on culture conditions. Internalization was temperature-dependent. At 37 degrees C in the presence of cycloheximide or actinomycin D, the half-life of cell surface MFRs was 2 h, independent of receptor occupancy. Binding of fibrinogen to the MFR resulted in a down-regulation which was fibrinogen dose-dependent. This occurred in serum-supplemented medium but not in defined medium supplemented with fatty acids. Reexpression of MFRs could be induced in 28 to 42 h by serum removal. The down-regulation of mitogenic receptors in plasma or serum could explain why normal cells do not proliferate in the peripheral blood.

  12. A high sensitivity momentum flux measuring instrument for plasma thruster exhausts and diffusive plasmas.

    Science.gov (United States)

    West, Michael D; Charles, Christine; Boswell, Rod W

    2009-05-01

    A high sensitivity momentum flux measuring instrument based on a compound pendulum has been developed for use with electric propulsion devices and radio frequency driven plasmas. A laser displacement system, which builds upon techniques used by the materials science community for surface stress measurements, is used to measure with high sensitivity the displacement of a target plate placed in a plasma thruster exhaust. The instrument has been installed inside a vacuum chamber and calibrated via two different methods and is able to measure forces in the range of 0.02-0.5 mN with a resolution of 15 microN. Measurements have been made of the force produced from the cold gas flow and with a discharge ignited using argon propellant. The plasma is generated using a Helicon Double Layer Thruster prototype. The instrument target is placed about 1 mean free path for ion-neutral charge exchange collisions downstream of the thruster exit. At this position, the plasma consists of a low density ion beam (10%) and a much larger downstream component (90%). The results are in good agreement with those determined from the plasma parameters measured with diagnostic probes. Measurements at various flow rates show that variations in ion beam velocity and plasma density and the resulting momentum flux can be measured with this instrument. The instrument target is a simple, low cost device, and since the laser displacement system used is located outside the vacuum chamber, the measurement technique is free from radio frequency interference and thermal effects. It could be used to measure the thrust in the exhaust of other electric propulsion devices and the momentum flux of ion beams formed by expanding plasmas or fusion experiments.

  13. [High beta tokamak research and plasma theory

    International Nuclear Information System (INIS)

    1990-01-01

    Our activities on High Beta Tokamak Research during the past 12 months of the present budget period can be divided into four areas: completion of kink mode studies in HBT; completion of carbon impurity transport studies in HBT; design of HBT-EP; and construction of HBT-EP. Each of these is described briefly in the sections of this progress report

  14. Application of Plasma Waveguides to High Energy Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Milchberg, Howard M

    2013-03-30

    The eventual success of laser-plasma based acceleration schemes for high-energy particle physics will require the focusing and stable guiding of short intense laser pulses in reproducible plasma channels. For this goal to be realized, many scientific issues need to be addressed. These issues include an understanding of the basic physics of, and an exploration of various schemes for, plasma channel formation. In addition, the coupling of intense laser pulses to these channels and the stable propagation of pulses in the channels require study. Finally, new theoretical and computational tools need to be developed to aid in the design and analysis of experiments and future accelerators. Here we propose a 3-year renewal of our combined theoretical and experimental program on the applications of plasma waveguides to high-energy accelerators. During the past grant period we have made a number of significant advances in the science of laser-plasma based acceleration. We pioneered the development of clustered gases as a new highly efficient medium for plasma channel formation. Our contributions here include theoretical and experimental studies of the physics of cluster ionization, heating, explosion, and channel formation. We have demonstrated for the first time the generation of and guiding in a corrugated plasma waveguide. The fine structure demonstrated in these guides is only possible with cluster jet heating by lasers. The corrugated guide is a slow wave structure operable at arbitrarily high laser intensities, allowing direct laser acceleration, a process we have explored in detail with simulations. The development of these guides opens the possibility of direct laser acceleration, a true miniature analogue of the SLAC RF-based accelerator. Our theoretical studies during this period have also contributed to the further development of the simulation codes, Wake and QuickPIC, which can be used for both laser driven and beam driven plasma based acceleration schemes. We

  15. Characteristics of extreme ultraviolet emission from high-Z plasmas

    International Nuclear Information System (INIS)

    Ohashi, H.; Higashiguchi, T.; Suzuki, Y.; Kawasaki, M.; Suzuki, C.; Tomita, K.; Nishikino, M.; Fujioka, S.; Endo, A.; Li, B.; Otsuka, T.; Dunne, P.; O'Sullivan, G.

    2016-01-01

    We demonstrate the extreme ultraviolet (EUV) and soft x-ray sources in the 2 to 7 nm spectral region related to the beyond EUV (BEUV) question at 6.x nm and the water window source based on laser-produced high-Z plasmas. Resonance emission from multiply charged ions merges to produce intense unresolved transition arrays (UTAs), extending below the carbon K edge (4.37 nm). An outline of a microscope design for single-shot live cell imaging is proposed based on high-Z plasma UTA source, coupled to multilayer mirror optics. (paper)

  16. Observation of high-temperature bubbles in an ECR plasma

    Science.gov (United States)

    Terasaka, K.; Yoshimura, S.; Tanaka, M. Y.

    2018-05-01

    Creation and annihilation of high-temperature bubbles have been observed in an electron cyclotron resonance plasma. The electron temperature in the bubble core is three times higher than that in the ambient region, and the size perpendicular to the magnetic field is much smaller than the plasma diameter. Formation of a bubble accompanies large negative spikes in the floating potential of a Langmuir probe, and the spatiotemporal behavior of the bubble has been visualized with a high-impedance wire grid detector. It is found that the bubble is in a prolate spheroidal shape with the axis along the magnetic field and occurs randomly in time and independently in space.

  17. High speed photography diagnostics in laser-plasma interaction experiments

    International Nuclear Information System (INIS)

    Andre, M.L.

    1988-01-01

    The authors report on their effort in the development of techniques involved in laser-plasma experiments. This includes not only laser technology but also diagnostics studies and targets design and fabrication. Among the different kind of diagnostics currently used are high speed streak cameras, fast oscilloscopes and detectors sensitive in the i.r., visible, the u.v. region and the x-rays. In this presentation the authors describe the three high power lasers which are still in operation (P 102, OctAL and PHEBUS) and the main diagnostics used to characterize the plasma

  18. Characteristics of extreme ultraviolet emission from high-Z plasmas

    Science.gov (United States)

    Ohashi, H.; Higashiguchi, T.; Suzuki, Y.; Kawasaki, M.; Suzuki, C.; Tomita, K.; Nishikino, M.; Fujioka, S.; Endo, A.; Li, B.; Otsuka, T.; Dunne, P.; O'Sullivan, G.

    2016-03-01

    We demonstrate the extreme ultraviolet (EUV) and soft x-ray sources in the 2 to 7 nm spectral region related to the beyond EUV (BEUV) question at 6.x nm and the water window source based on laser-produced high-Z plasmas. Resonance emission from multiply charged ions merges to produce intense unresolved transition arrays (UTAs), extending below the carbon K edge (4.37 nm). An outline of a microscope design for single-shot live cell imaging is proposed based on high-Z plasma UTA source, coupled to multilayer mirror optics.

  19. Hybrid simulation of electrode plasmas in high-power diodes

    International Nuclear Information System (INIS)

    Welch, Dale R.; Rose, David V.; Bruner, Nichelle; Clark, Robert E.; Oliver, Bryan V.; Hahn, Kelly D.; Johnston, Mark D.

    2009-01-01

    New numerical techniques for simulating the formation and evolution of cathode and anode plasmas have been successfully implemented in a hybrid code. The dynamics of expanding electrode plasmas has long been recognized as a limiting factor in the impedance lifetimes of high-power vacuum diodes and magnetically insulated transmission lines. Realistic modeling of such plasmas is being pursued to aid in understanding the operating characteristics of these devices as well as establishing scaling relations for reliable extrapolation to higher voltages. Here, in addition to kinetic and fluid modeling, a hybrid particle-in-cell technique is described that models high density, thermal plasmas as an inertial fluid which transitions to kinetic electron or ion macroparticles above a prescribed energy. The hybrid technique is computationally efficient and does not require resolution of the Debye length. These techniques are first tested on a simple planar diode then applied to the evolution of both cathode and anode plasmas in a high-power self-magnetic pinch diode. The impact of an intense electron flux on the anode surface leads to rapid heating of contaminant material and diode impedance loss.

  20. The binding of fibrinogen to platelets in diabetes mellitus

    International Nuclear Information System (INIS)

    Minno, G. di; Cerbone, A.M.; Iride, C.; Mancini, M.

    1986-01-01

    Platelets from diabetics are known to be more sensitive in vitro to a variety of aggregating agents, to produce more prostaglandin endoperoxides and thromboxane and to bind more 125 I-fibrinogen than platelets from normal controls. Fibrinogen binding to platelets is a pre-requisite for platelet aggregation. Previous studies suggested a role for prostaglandins and/or thrombaxane A 2 in the exposure of fibrinogen receptors on platelets. The present study compares fibrinogen binding to hyperaggregable platelets from diabetic patients and to normal platelets when prostaglandin/thromboxane formation is suppressed by aspirin. It was found that pre-treatment with aspirin reduced collagen or thrombin-induced binding to platelets from none-retinopathic diabetics to the values seen in controls. By contrast, aspirin did not normalize binding to platelets obtained from retinopathic diabetics. The combination of aspirin with apyrase (an ADP scavenger) almost completely inhibited binding and aggregation of platelets from normal controls or non-retinophatic diabetics exposed to collagen or thrombin, whereas it only partially affected binding and aggregation of platelets from retinopathics. By using a monoclonal antibody (B59.2) to the platelet receptor for fibrinogen, we determined that this receptor was quantitatively and qualitatively the same on platelets from normal controls and diabetics. We conclude that increased fibrinogen binding and hyperaggregability of platelets from none-retinopathic diabetics is related to their capacity to form more prostaglandin endoperoxides/thromboxane than normal platelets. In contrast, hyperaggregability and increased binding of platelets from retinopathics appear at least partly related to a mechanism independent of ADP release and thromboxane synthesis. (Author)

  1. Monoaminylation of Fibrinogen and Glia-Derived Proteins: Indication for Similar Mechanisms in Posttranslational Protein Modification in Blood and Brain.

    Science.gov (United States)

    Hummerich, René; Costina, Victor; Findeisen, Peter; Schloss, Patrick

    2015-07-15

    Distinct proteins have been demonstrated to be posttranslationally modified by covalent transamidation of serotonin (5-hydropxytryptamin) to glutamine residues of the target proteins. This process is mediated by transglutaminase (TGase) and has been termed "serotonylation." It has also been shown that other biogenic amines, including the neurotransmitters dopamine and norepinephrine, can substitute for serotonin, implying a more general mechanism of "monoaminylation" for this kind of protein modification. Here we transamidated the autofluorescent monoamine monodansylcadaverine (MDC) to purified plasma fibrinogen and to proteins from a primary glia cell culture. Electrophoretic separation of MDC-conjugated proteins followed by mass spectrometry identified three fibrinogen subunits (Aα, Bβ, γ), a homomeric Aα2 dimer, and adducts of >250 kDa molecular weight, as well as several glial proteins. TGase-mediated MDC incorporation was strongly reduced by serotonin, underlining the general mechanism of monoaminylation.

  2. Fibrate-modulated expression of fibrinogen, plasminogen activator inhibitor-1 and apolipoprotein A-I in cultured cynomolgus monkey hepatocytes. Role of the peroxisome proliferator-activated receptor-α

    NARCIS (Netherlands)

    Kockx, M.; Princen, H.M.G.; Kooistra, T.

    1998-01-01

    Fibrates are used to lower plasma triglycerides and cholesterol levels in hyperlipidemic patients. In addition, fibrates have been found to alter the plasma concentrations of fibrinogen, plasminogen activator inhibitor-1 (PAI-1) and apolipoprotein A-I (apo A-I). We have investigated the in vitro

  3. [Ratio of erythrocyte and plasma in massive blood transfusion].

    Science.gov (United States)

    Wen, Xian-Hui; Liu, Feng-Xia; Zhang, Jun-Hua; Gui, Rong

    2014-06-01

    This study was purposed to explore the suitable ratio between fresh frozen plasma and erythrocyte by retrospective analysis of coagulation in patients with massive blood transfusion. The clinical data of 151 cases with massive blood transfusion from January 2011 to January 2013 were analyzed retrospectively. According to coagulation, patients were divided into coagulation normal group (138 cases) and coagulation dysfunction group (13 cases). Based on the ratio of 1:1 of fresh frozen plasma and erythrocyte, the patients were divided into high plasma group(2:1), medium plasma group (1:1) and low plasma (blood transfusion. The results showed that prothrombin time (PT), activated partial thromboplastin time (APTT) and thrombin time (TT) were prolonged, fibrinogen (FIB) level decreased significantly (all P blood transfusion 24 h; the high plasma and the medium plasma group of coagulation normal group had no significant changes in coagulation (P > 0.05); prothrombin time, activated partial thromboplastin time, thrombin time and fibrinogen level in the medium plasma and low plasma subgroup of coagulation dysfunction group after massive transfusion was still in abnormal levels (P > 0.05), coagulation function in high plasma subgroup was improved significantly (P blood transfusion, the ratio between fresh frozen plasma and erythrocyte is recommended to be 2:1 in patients of coagulation dysfunction in order to improve the patient's coagulation function and to reduce the incidence of adverse event, the ratio of fresh frozen plasma to erythrocyte is recommended to be 1:1 in patients with normal coagulation so as to reduce the dilutional coagulopathy and hypervolemia of blood.

  4. Rare coagulation disorders: fibrinogen, factor VII and factor XIII.

    Science.gov (United States)

    de Moerloose, P; Schved, J-F; Nugent, D

    2016-07-01

    Rare coagulation disorders (RCDs) include the inherited deficiencies of fibrinogen, factor (F) II, FV, combined FV and VIII, FVII, FX, combined FVII and X, FXI, FXIII and combined congenital deficiency of vitamin K-dependent factors (VKCFDs). Despite their rarity, a deep comprehension of all these disorders is essential to really understand haemostasis. Indeed, even if they share some common features each RCD has some particularity which makes it unique. In this review, we focus on three disorders: fibrinogen, FVII and FXIII. © 2016 John Wiley & Sons Ltd.

  5. Studies on the propagation of relativistic plasma waves in high density plasmas produced by hypersonic ionizing shock waves

    International Nuclear Information System (INIS)

    Williams, R.L.; Johnson, J.A. III

    1993-01-01

    The feasibility of using an ionizing shock wave to produce high density plasmas suitable for the propagation large amplitude relativistic plasma waves is being investigated. A 20 kv arc driven shock tube of coaxial geometry produces a hypersonic shock wave (10 p > 10 17 cm -3 ). The shock can be made to reflect off the end of the tube, collide with its wake, and thus increase the plasma density further. After reflecting, the plasma is at rest. The shock speed is measured using piezoelectric pressure probes and the ion density is measured using laser induced fluorescence (LIF) techniques on argon 488.0 nm and 422.8 nm lines. The future plans are to excite large amplitude relativistic plasma waves in this plasma by either injecting a short pulse laser (Laser Wake Field Scheme), two beating lasers (Plasma Beat Wave Scheme), or a short bunch of relativistic electrons (Plasma Wake Field Scheme). Results of recent computational and theoretical studies, as well as initial experimental measurements on the plasma using LIF, are reported. Implications for the application of high density plasmas produced in this way to such novel schemes as the plasma wave accelerator, photon accelerator, plasma wave undulator, and also plasma lens, are discussed. The effect of plasma turbulence is also discussed

  6. Sheath impedance effects in very high frequency plasma experiments

    International Nuclear Information System (INIS)

    Schwarzenbach, W.; Howling, A.A.; Fivaz, M.; Brunner, S.; Hollenstein, C.

    1995-05-01

    The frequency dependence (13.56 MHz to 70 MHz) of the ion energy distribution at the ground electrode was measured by mass spectrometry in a symmetrical capacitive argon discharge. Reduced sheath impedance at Very High Frequency allows high levels of plasma power and substrate ion flux whilst maintaining low levels of ion energy and electrode voltage. The lower limit of ion bombardment energy is fixed by the sheath floating potential at high frequency, in contrast to low frequencies where only the rf voltage amplitude is determinant. The capacitive sheaths are thinner at high frequencies which accentuates the high frequency reduction in sheath impedance. It is argued that the frequency dependence of sheath impedance is responsible for the principal characteristics of Very High Frequency plasmas. The measurements are summarised by simple physical descriptions and compared with a Particle-In-Cell simulation. (author) figs., tabs., refs

  7. A High Temperature Liquid Plasma Model of the Sun

    Directory of Open Access Journals (Sweden)

    Robitaille P.-M.

    2007-01-01

    Full Text Available In this work, a liquid model of the Sun is presented wherein the entire solar mass is viewed as a high density/high energy plasma. This model challenges our current understanding of the densities associated with the internal layers of the Sun, advocating a relatively constant density, almost independent of radial position. The incompressible nature of liquids is advanced to prevent solar collapse from gravitational forces. The liquid plasma model of the Sun is a non-equilibrium approach, where nuclear reactions occur throughout the solar mass. The primary means of addressing internal heat transfer are convection and conduction. As a result of the convective processes on the solar surface, the liquid model brings into question the established temperature of the solar photosphere by highlighting a violation of Kirchhoff’s law of thermal emission. Along these lines, the model also emphasizes that radiative emission is a surface phenomenon. Evidence that the Sun is a high density/high energy plasma is based on our knowledge of Planckian thermal emission and condensed matter, including the existence of pressure ionization and liquid metallic hydrogen at high temperatures and pressures. Prior to introducing the liquid plasma model, the historic and scientific justifications for the gaseous model of the Sun are reviewed and the gaseous equations of state are also discussed.

  8. On impurity handling in high performance stellarator/heliotron plasmas

    International Nuclear Information System (INIS)

    Burhenn, R.; Feng, Y.; Ida, K.

    2008-10-01

    The Large Helical Device (LHD) and Wendelstein 7-X (W7-X, under construction) are experiments specially designed to demonstrate long pulse (quasi steady-state) operation, which is an intrinsic property of Stellarators and Heliotrons. Significant progress was made in establishment of high performance plasmas. A crucial point is the increasing impurity confinement towards high density as observed at several machines (TJ-II, W7-AS, LHD) which can lead to impurity accumulation and early pulse termination by radiation collapse at high density. In addition, theoretical predictions for non-axisymmetric configurations prognosticate the absence of impurity screening by ion temperature gradients in standard ion root plasmas. Nevertheless, scenarios were found where impurity accumulation was successfully avoided in LHD and/or W7-AS by the onset of drag forces in the high density and low temperature scrape-off-layer, the generation of magnetic islands at the plasma boundary and to a certain degree also by ELMs, flushing out impurities and reducing the net-impurity influx into the core. Additionally, a reduction of impurity core confinement was observed in the W7-AS High Density H-mode (HDH) regime and by application of sufficient ECRH heating power. The exploration of such purification mechanisms is a demanding task for successful steady-state operation. The impurity transport at the plasma edge/SOL was identified to play a major role for the global impurity behaviour in addition to the core confinement. (author)

  9. Operation of the ORNL High Particle Flux Helicon Plasma Source

    International Nuclear Information System (INIS)

    Goulding, Richard Howell; Biewer, Theodore M.; Caughman, John B.; Chen, Guangye; Owen, Larry W.; Sparks, Dennis O.

    2011-01-01

    A high power, high particle flux rf-based helicon plasma source has been constructed at ORNL and operated at power levels up to 30 kW. High-density hydrogen and helium plasmas have been produced. The source has been designed as the basis for a linear plasma materials interaction (PMI) test facility that will generate particle fluxes Gamma(p) > 10(23) M-3 s(-1), and utilize additional ion and electron cyclotron heating to produce high parallel (to the magnetic field) heat fluxes of similar to 10 MW/m(2). An rf-based source for PMI research is of interest because high plasma densities are generated with no internal electrodes, allowing true steady state operation with minimal impurity generation. The ORNL helicon source has a diameter of 15 cm and to-date has operated at a frequency f = 13.56 MHz, with magnetic field strength vertical bar B vertical bar in the antenna region up to similar to 0.15 T. Maximum densities of 3 x 10(19) M-3 in He and 2.5 x 10(19) m(-3) in H have been achieved. Radial density profiles have been seen to be dependent on the axial vertical bar B vertical bar profile.

  10. Operation of the ORNL High Particle Flux Helicon Plasma Source

    International Nuclear Information System (INIS)

    Goulding, R. H.; Biewer, T. M.; Caughman, J. B. O.; Chen, G. C.; Owen, L. W.; Sparks, D. O.

    2011-01-01

    A high power, high particle flux rf-based helicon plasma source has been constructed at ORNL and operated at power levels up to 30 kW. High-density hydrogen and helium plasmas have been produced. The source has been designed as the basis for a linear plasma materials interaction (PMI) test facility that will generate particle fluxes Γ p 10 23 m -3 s -1 , and utilize additional ion and electron cyclotron heating to produce high parallel (to the magnetic field) heat fluxes of ∼10 MW/m 2 . An rf-based source for PMI research is of interest because high plasma densities are generated with no internal electrodes, allowing true steady state operation with minimal impurity generation. The ORNL helicon source has a diameter of 15 cm and to-date has operated at a frequency f = 13.56 MHz, with magnetic field strength |B| in the antenna region up to ∼0.15 T. Maximum densities of 3x10 19 m -3 in He and 2.5x10 19 m -3 in H have been achieved. Radial density profiles have been seen to be dependent on the axial |B| profile.

  11. High resolution X-ray spectromicroscopy of laser produced plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Faenov, A.Ya. [Multi-charged Ions Spectra Data Center of VNIIFTRI (MISDC), Mendeleevo, Moscow region, (Russian Federation)

    2000-01-01

    In recent years new classes of X-ray spectroscopic instruments possessing both dispersive and focusing properties have been manufactured. Their principal advantage over more traditional instruments is that they combine very high luminosity with high spatial resolution, while preserving the highest possible spectral resolution of their dispersive elements. These instruments opened up the registration of plasmas in new regimes and surroundings. The measurements delivered new information about the properties of even previously studied traditional plasma objects (e.g. ns-laser produced plasmas). Also the detailed investigation of relatively new plasma laboratory sources with very small dimensions and low energy content (e.g. mJ fs-laser pulses) became possible. The purpose of this report is to give a short review of the experimental and theoretical results obtained in the past few years by MISDC (Multi-charged Ions Spectra Data Center) research team in the field of X-ray spectroscopy of a laser-produced plasma. Experimental spectra have been obtained at various laser installations with nanosecond, sub-nanosecond, picosecond and sub-picosecond pulses interacting with solid, gaseous or cluster targets in collaborations with research teams from Russia, USA, Germany, France, Poland, Belgium, Italy, China and Israel. Practically all results have been obtained with the help of spectrographs with spherically bent mica crystals operating in FSSR-1D, 2D schemes. (author)

  12. High-performance modeling of plasma-based acceleration and laser-plasma interactions

    Science.gov (United States)

    Vay, Jean-Luc; Blaclard, Guillaume; Godfrey, Brendan; Kirchen, Manuel; Lee, Patrick; Lehe, Remi; Lobet, Mathieu; Vincenti, Henri

    2016-10-01

    Large-scale numerical simulations are essential to the design of plasma-based accelerators and laser-plasma interations for ultra-high intensity (UHI) physics. The electromagnetic Particle-In-Cell (PIC) approach is the method of choice for self-consistent simulations, as it is based on first principles, and captures all kinetic effects, and also scale favorably to many cores on supercomputers. The standard PIC algorithm relies on second-order finite-difference discretization of the Maxwell and Newton-Lorentz equations. We present here novel formulations, based on very high-order pseudo-spectral Maxwell solvers, which enable near-total elimination of the numerical Cherenkov instability and increased accuracy over the standard PIC method for standard laboratory frame and Lorentz boosted frame simulations. We also present the latest implementations in the PIC modules Warp-PICSAR and FBPIC on the Intel Xeon Phi and GPU architectures. Examples of applications will be given on the simulation of laser-plasma accelerators and high-harmonic generation with plasma mirrors. Work supported by US-DOE Contracts DE-AC02-05CH11231 and by the European Commission through the Marie Slowdoska-Curie fellowship PICSSAR Grant Number 624543. Used resources of NERSC.

  13. Development of dispersion interferometer for magnetic confinement plasmas and high-pressure plasmas

    Science.gov (United States)

    Akiyama, T.; Yasuhara, R.; Kawahata, K.; Nakayama, K.; Okajima, S.; Urabe, K.; Terashima, K.; Shirai, N.

    2015-09-01

    A CO2 laser dispersion interferometer (DI) has been developed for both magnetically fusion plasmas and high pressure industrial plasmas. The DI measures the phase shift caused by dispersion in a medium. Therefore, it is insensitive to the mechanical vibrations and changes in the neutral gas density, which degrade the resolution of the electron density measurement. We installed the DI on the Large Helical Device (LHD) and demonstrated a high density resolution of 2× 1017 m-3 without any vibration-free bench. The measured electron density with the DI shows good agreement with results of the existing far infrared laser (a wavelength of 119 μ m) interferometer. The DI system is also applied to the electron density measurement of high-pressure small-scale plasmas. The significant suppression of the phase shift caused by the neutral gas is proven. The achieved density resolution was 1.5× 1019 m-3 with a response time of 100 μ s. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  14. Bacteroides gingivalis and Bacteroides intermedius recognize different sites on human fibrinogen

    International Nuclear Information System (INIS)

    Lantz, M.S.; Allen, R.D.; Bounelis, P.; Switalski, L.M.; Hook, M.

    1990-01-01

    Bacteroides (Porphyromonas) gingivalis and Bacteroides (Porphyromonas) intermedius have been implicated in the etiology of human periodontal diseases. These organisms are able to bind and degrade human fibrinogen, and these interactions may play a role in the pathogenesis of periodontal disease. In attempts to map the bacterial binding sites along the fibrinogen molecule, we have found that strains of B. gingivalis and B. intermedius, respectively, recognize spatially distant and distinct sites on the fibrinogen molecule. Isolated reduced and alkylated alpha-, beta-, and gamma-fibrinogen chains inhibited binding of 125I-fibrinogen to both Bacteroides species in a concentration-dependent manner. Plasmin fragments D and to some extent fragment E, however, produced a concentration-dependent inhibition of 125I-fibrinogen binding to B. intermedius strains but did not affect binding of 125I-fibrinogen to B. gingivalis strains. Radiolabeled fibrinogen chains and fragments were compared with 125I-fibrinogen with respect to specificity and reversibility of binding to bacteria. According to these criteria, gamma chain most closely resembled the native fibrinogen molecule in behavior toward B. gingivalis strains and fragments D most closely resembled fibrinogen in behavior toward B. intermedius strains. The ability of anti-human fibrinogen immunoglobulin G (IgG) to inhibit binding of 125I-fibrinogen to B. intermedius strains was greatly reduced by absorbing the IgG with fragments D. Absorbing the IgG with fragments D had no effect on the ability of the antibody to inhibit binding of 125I-fibrinogen to B. gingivalis strains. A purified staphylococcal fibrinogen-binding protein blocked binding of 125I-fibrinogen to B. intermedius strains but not to B. gingivalis strains

  15. Bacteroides gingivalis and Bacteroides intermedius recognize different sites on human fibrinogen

    Energy Technology Data Exchange (ETDEWEB)

    Lantz, M.S.; Allen, R.D.; Bounelis, P.; Switalski, L.M.; Hook, M. (Univ. of Alabama, Birmingham (USA))

    1990-02-01

    Bacteroides (Porphyromonas) gingivalis and Bacteroides (Porphyromonas) intermedius have been implicated in the etiology of human periodontal diseases. These organisms are able to bind and degrade human fibrinogen, and these interactions may play a role in the pathogenesis of periodontal disease. In attempts to map the bacterial binding sites along the fibrinogen molecule, we have found that strains of B. gingivalis and B. intermedius, respectively, recognize spatially distant and distinct sites on the fibrinogen molecule. Isolated reduced and alkylated alpha-, beta-, and gamma-fibrinogen chains inhibited binding of 125I-fibrinogen to both Bacteroides species in a concentration-dependent manner. Plasmin fragments D and to some extent fragment E, however, produced a concentration-dependent inhibition of 125I-fibrinogen binding to B. intermedius strains but did not affect binding of 125I-fibrinogen to B. gingivalis strains. Radiolabeled fibrinogen chains and fragments were compared with 125I-fibrinogen with respect to specificity and reversibility of binding to bacteria. According to these criteria, gamma chain most closely resembled the native fibrinogen molecule in behavior toward B. gingivalis strains and fragments D most closely resembled fibrinogen in behavior toward B. intermedius strains. The ability of anti-human fibrinogen immunoglobulin G (IgG) to inhibit binding of 125I-fibrinogen to B. intermedius strains was greatly reduced by absorbing the IgG with fragments D. Absorbing the IgG with fragments D had no effect on the ability of the antibody to inhibit binding of 125I-fibrinogen to B. gingivalis strains. A purified staphylococcal fibrinogen-binding protein blocked binding of 125I-fibrinogen to B. intermedius strains but not to B. gingivalis strains.

  16. Electrostatic and electromagnetic traps for high-temperature plasma

    International Nuclear Information System (INIS)

    Lavrent'ev, O.A.

    Theoretical and experimental aspects of thermal isolation are considered for a high-temperature plasma in systems with electrostatic as well as electric and magnetic fields. Specific types of traps are discussed, together with diagnostic methods and fundamental experimental results. (U.S.)

  17. A high-voltage pulse generator for corona plasma generation

    NARCIS (Netherlands)

    Yan, K.; Heesch, van E.J.M.; Pemen, A.J.M.; Huijbrechts, P.A.H.J.; Gompel, van F.M.; Leuken, van H.E.M.; Matyas, Z.

    2002-01-01

    This paper discusses a high-voltage pulse generator for producing corona plasma. The generator consists of three resonant charging circuits, a transmission line transformer, and a triggered spark-gap switch. Voltage pulses in the order of 30-100 kV with a rise time of 10-20 ns, a pulse duration of

  18. Simulation of transition dynamics to high confinement in fusion plasmas

    DEFF Research Database (Denmark)

    Nielsen, Anders Henry; Xu, G. S.; Madsen, Jens

    2015-01-01

    The transition dynamics from the low (L) to the high (H) confinement mode in magnetically confined plasmas is investigated using a first-principles four-field fluid model. Numerical results are in agreement with measurements from the Experimental Advanced Superconducting Tokamak - EAST...

  19. Discharge efficiency in high-Xe-content plasma display panels

    NARCIS (Netherlands)

    Hayashi, D.; Kroesen, G.M.W.; Hagelaar, G.J.M.; Heusler, G.

    2004-01-01

    We study theoretically the overall output performance and the dominating reaction processes of the vacuum ultraviolet (UV) radiation production in high-Xe partial pressures in plasma display panels (PDPs) with Ne-Xe gas mixtures. A two-dimensional self-consistent fluid model is applied for the

  20. Characterizing electrostatic turbulence in tokamak plasmas with high MHD activity

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes-Filho, Z O; Santos Lima, G Z dos; Caldas, I L; Nascimento, I C; Kuznetsov, Yu K [Instituto de Fisica, Universidade de Sao Paulo, Caixa Postal 66316, 05315-970, Sao Paulo, SP (Brazil); Viana, R L, E-mail: viana@fisica.ufpr.b [Departamento de Fisica, Universidade Federal do Parana, Caixa Postal 19044, 81531-990, Curitiba, PR (Brazil)

    2010-09-01

    One of the challenges in obtaining long lasting magnetic confinement of fusion plasmas in tokamaks is to control electrostatic turbulence near the vessel wall. A necessary step towards achieving this goal is to characterize the turbulence level and so as to quantify its effect on the transport of energy and particles of the plasma. In this paper we present experimental results on the characterization of electrostatic turbulence in Tokamak Chauffage Alfven Bresilien (TCABR), operating in the Institute of Physics of University of Sao Paulo, Brazil. In particular, we investigate the effect of certain magnetic field fluctuations, due to magnetohydrodynamical (MHD) instabilities activity, on the spectral properties of electrostatic turbulence at plasma edge. In some TCABR discharges we observe that this MHD activity may increase spontaneously, following changes in the edge safety factor, or after changes in the radial electric field achieved by electrode biasing. During the high MHD activity, the magnetic oscillations and the plasma edge electrostatic turbulence present several common linear spectral features with a noticeable dominant peak in the same frequency. In this article, dynamical analyses were applied to find other alterations on turbulence characteristics due to the MHD activity and turbulence enhancement. A recurrence quantification analysis shows that the turbulence determinism radial profile is substantially changed, becoming more radially uniform, during the high MHD activity. Moreover, the bicoherence spectra of these two kinds of fluctuations are similar and present high bicoherence levels associated with the MHD frequency. In contrast with the bicoherence spectral changes, that are radially localized at the plasma edge, the turbulence recurrence is broadly altered at the plasma edge and the scrape-off layer.

  1. High-speed photographic observation of plasma-limiter interactions in ISX-B

    International Nuclear Information System (INIS)

    Clausing, R.E.; Emerson, L.C.; Heatherly, L.

    1981-01-01

    High-speed motion pictures confirm that arcing occurs during periods of plasma instability in ISX-B. Various types of plasma-limiter interactions are described and illustrated. Arcing and other visible phenomena are correlated to plasma parameters

  2. Internal Kink Mode Dynamics in High-β NSTX Plasmas

    International Nuclear Information System (INIS)

    Menard, J.E.; Bell, R.E.; Fredrickson, E.D.; Gates, D.A.; Kaye, S.M.; LeBlanc, B.P.; Medley, S.S.; Park, W.; Sabbagh, S.A.; Sontag, A.; Stutman, D.; Tritz, K.; Zhu, W.

    2004-01-01

    Saturated internal kink modes have been observed in many of the highest toroidal beta discharges of the National Spherical Torus Experiment (NSTX). These modes often cause rotation flattening in the plasma core, can degrade energy confinement, and in some cases contribute to the complete loss of plasma angular momentum and stored energy. Characteristics of the modes are measured using soft X-ray, kinetic profile, and magnetic diagnostics. Toroidal flows approaching Alfvenic speeds, island pressure peaking, and enhanced viscous and diamagnetic effects associated with high-beta may contribute to mode nonlinear stabilization. These saturation mechanisms are investigated for NSTX parameters and compared to experimental data

  3. Internal kink mode dynamics in high-β NSTX plasmas

    International Nuclear Information System (INIS)

    Menard, J.E.; Bell, R.E.; Fredrickson, E.D.; Gates, D.A.; Kaye, S.M.; LeBlanc, B.P.; Medley, S.S.; Park, W.; Sabbagh, S.A.; Sontag, A.; Zhu, W.; Stutman, D.; Tritz, K.

    2005-01-01

    Saturated internal kink modes have been observed in many of the highest toroidal beta discharges of the National Spherical Torus Experiment (NSTX). These modes often cause rotation flattening in the plasma core, can degrade energy confinement, and in some cases contribute to the complete loss of plasma angular momentum and stored energy. Characteristics of the modes are measured using soft X-ray, kinetic profile, and magnetic diagnostics. Toroidal flows approaching Alfvenic speeds, island pressure peaking, and enhanced viscous and diamagnetic effects associated with high-beta may contribute to mode non-linear stabilization. These saturation mechanisms are investigated for NSTX parameters and compared to experiment. (author)

  4. Endogenous magnetic reconnection and associated high energy plasma processes

    Science.gov (United States)

    Coppi, B.; Basu, B.

    2018-02-01

    An endogenous reconnection process involves a driving factor that lays inside the layer where a drastic change of magnetic field topology occurs. A process of this kind is shown to take place when an electron temperature gradient is present in a magnetically confined plasma and the evolving electron temperature fluctuations are anisotropic. The width of the reconnecting layer remains significant even when large macroscopic distances are considered. In view of the fact that there are plasmas in the Universe with considerable electron thermal energy contents this feature can be relied upon in order to produce generation or conversion of magnetic energy, high energy particle populations and momentum and angular momentum transport.

  5. 14th High-Tech Plasma Processes Conference (HTPP 14)

    Science.gov (United States)

    2017-04-01

    Preface The High-Tech Plasma Processes Conference (HTPP) is a bi-annual international conference based in Europe with topics encompassing the whole area of plasma processing science. This conference is open to all the international community in the world involved in plasma science and plasma technology. The aim of the conference is to bring different scientific communities together, facilitate the contacts between science, technology and industry and provide a platform for the exploration of both fundamental topics and new applications of plasmas. For this edition of HTPP, as was the case for the last, we have achieved a well balanced participation from the communities of both thermal and non-thermal plasma researchers. 75 people from 17 countries attended the conference with the total number of contributions being 74, consisting of 19 invited talks and 55 poster contributions. As a HTPP tradition a poster competition has been carried out during the conference. The winner of the poster competition was Fabrice Mavier from Université de Limoges, France with his paper “Pulsed arc plasma jet synchronized with drop-on-demand dispenser” All the participants also ejoyed the social program including an “unconventional” tour of the city, the visit to the famous Hofbräuhaus and the dinner at the Blutenburg, a beautiful inner-city castle. We have received papers corresponding to the contributions of HTPP-2014 that have been submitted for publication in this volume of Journal of Physics: Conference Series. Each submitted contribution has been peer reviewed and the Editors are very grateful to the referees for their careful support in improving the original manuscripts. In total, 18 manuscripts have been accepted for publication covering a range of topics of plasma processing science from plasma fundamentals to process applications through to experiments, diagnostics and modelling. We deeply thank the authors for their enthusiastic and high-grade contributions and we

  6. Conference on atomic processes in high temperature plasmas: a topical conference of the American Physical Society Division of Plasma Physics

    International Nuclear Information System (INIS)

    1977-01-01

    Abstracts are included for approximately 100 of the papers presented at the meeting. The following sessions were held at the conference: (1) electron ionization and excitation rates, (2) radiation from low density plasmas, (3) electron-ion cross sections and rates, (4) oscillator strengths and atomic structure, (5) spectroscopy and atomic structure, (6) astrophysical plasmas, (7) particle transport, (8) ion-atom cross sections and rates, (9) wall effects in laboratory plasmas, (10) spectroscopy and photoionization, and (11) radiation from high density plasmas

  7. 21 CFR 864.7320 - Fibrinogen/fibrin degradation products assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fibrinogen/fibrin degradation products assay. 864.7320 Section 864.7320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN....7320 Fibrinogen/fibrin degradation products assay. (a) Identification. A fibrinogen/fibrin degradation...

  8. The efficacy of fibrinogen concentrate compared with cryoprecipitate in major obstetric haemorrhage - an observational study.

    LENUS (Irish Health Repository)

    Ahmed, S

    2012-10-01

    Fibrinogen replacement is critical in major obstetric haemorrhage (MOH). Purified, pasteurised fibrinogen concentrate appears to have benefit over cryoprecipitate in ease of administration and safety but is unlicensed in pregnancy. In July 2009, the Irish Blood Transfusion Service replaced cryoprecipitate with fibrinogen.

  9. Wall stabilization of high beta plasmas in DIII-D

    International Nuclear Information System (INIS)

    Taylor, T.S.; Strait, E.J.; Lao, L.L.; Turnbull, A.D.; Burrell, K.H.; Chu, M.S.; Ferron, J.R.; Groebner, R.J.; La Haye, R.J.; Mauel, M.

    1995-02-01

    Detailed analysis of recent high beta discharges in the DIII-D tokamak demonstrates that the resistive vacuum vessel can provide stabilization of low n magnetohydrodynamic (MHD) modes. The experimental beta values reaching up to β T = 12.6% are more than 30% larger than the maximum stable beta calculated with no wall stabilization. Plasma rotation is essential for stabilization. When the plasma rotation slows sufficiently, unstable modes with the characteristics of the predicted open-quotes resistive wallclose quotes mode are observed. Through slowing of the plasma rotation between the q = 2 and q = 3 surfaces with the application of a non-axisymmetric field, the authors have determined that the rotation at the outer rational surfaces is most important, and that the critical rotation frequency is of the order of Ω/2π = 1 kHz

  10. Angular dependence of high Mach number plasma interactions

    International Nuclear Information System (INIS)

    Thomas, V.A.; Brecht, S.H.

    1987-01-01

    In this paper a 2-1/2-dimensional hybrid code is used to examine the collisionless large spatial scale (kc/ω pi ∼ 1) low-frequency (ω ∼ ω ci ) interaction initiated by a plasma shell of finite width traveling at high Alfven Mach number relative to a uniform background plasma. Particular attention is given to the angle of the relative velocity relative to the ambient magnetic field for the range of angles O < θ < π/2. An attempt is made to parameterize some of the important physics including the Alfven ion cyclotron instability, the field-aligned electromagnetic ion counter streaming instability, mixing of the plasma shell with the background ions, and structuring of the interaction region. These results are applicable to various astrophysical interactions such as bow shocks and interplanetary shocks

  11. High intensity surface plasma waves, theory and PIC simulations

    Science.gov (United States)

    Raynaud, M.; Héron, A.; Adam, J.-C.

    2018-01-01

    With the development of intense (>1019 W cm-2) short pulses (≤25 fs) laser with very high contrast, surface plasma wave (SPW) can be explored in the relativistic regime. As the SPW propagates with a phase velocity close to the speed of light it may results in a strong acceleration of electron bunches along the surface permitting them to reach relativistic energies. This may be important e.g. for applications in the field of plasma-based accelerators. We investigate in this work the excitation of SPWs on grating preformed over-dense plasmas for laser intensities ranging from 1019 up to 1021 W cm-2. We discuss the nature of the interaction with respect to the solid case in which surface plasmon can be resonantly excited with weak laser intensity. In particular, we show the importance of the pulse duration and focalization of the laser beam on the amplitude of the SPW.

  12. Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry.

    Science.gov (United States)

    van den Bekerom, Dirk; den Harder, Niek; Minea, Teofil; Gatti, Nicola; Linares, Jose Palomares; Bongers, Waldo; van de Sanden, Richard; van Rooij, Gerard

    2017-08-01

    A flowing microwave plasma based methodology for converting electric energy into internal and/or translational modes of stable molecules with the purpose of efficiently driving non-equilibrium chemistry is discussed. The advantage of a flowing plasma reactor is that continuous chemical processes can be driven with the flexibility of startup times in the seconds timescale. The plasma approach is generically suitable for conversion/activation of stable molecules such as CO2, N2 and CH4. Here the reduction of CO2 to CO is used as a model system: the complementary diagnostics illustrate how a baseline thermodynamic equilibrium conversion can be exceeded by the intrinsic non-equilibrium from high vibrational excitation. Laser (Rayleigh) scattering is used to measure the reactor temperature and Fourier Transform Infrared Spectroscopy (FTIR) to characterize in situ internal (vibrational) excitation as well as the effluent composition to monitor conversion and selectivity.

  13. High speed and high functional inverter power supplies for plasma generation and control, and their performance

    International Nuclear Information System (INIS)

    Uesugi, Yoshihiko; Razzak, Mohammad A.; Kondo, Kenji; Kikuchi, Yusuke; Takamura, Shuichi; Imai, Takahiro; Toyoda, Mitsuhiro

    2003-01-01

    The Rapid development of high power and high speed semiconductor switching devices has led to their various applications in related plasma fields. Especially, a high speed inverter power supply can be used as an RF power source instead of conventional linear amplifiers and a power supply to control the magnetic field in a fusion plasma device. In this paper, RF thermal plasma production and plasma heating experiments are described emphasis placed on using a static induction transistor inverter at a frequency range between 200 kHz and 2.5 MHz as an RF power supply. Efficient thermal plasma production is achieved experimentally by using a flexible and easily operated high power semiconductor inverter power supply. Insulated gate bipolar transistor (IGBT) inverter power supplies driven by a high speed digital signal processor are applied as tokamak joule coil and vertical coil power supplies to control plasma current waveform and plasma equilibrium. Output characteristics, such as the arbitrary bipolar waveform generation of a pulse width modulation (PWM) inverter using digital signal processor (DSP) can be successfully applied to tokamak power supplies for flexible plasma current operation and fast position control of a small tokamak. (author)

  14. Tungsten and carbon surface change under high dose plasma exposure

    International Nuclear Information System (INIS)

    Martynenko, Y.V.; Khripunov, B.I.; Petrov, V.B.

    2009-01-01

    Study of surface composition dynamics has been made on the LENTA linear plasma simulator. Experiments have been made on tungsten and carbon materials subjected to steady-state plasma exposure. The achieved ion doses on the surface were 10 21 ion cm -2 . WL 10 tungsten containing 1% of La2O3 oxide and titanium-doped graphite RG-T were studied. The following experimental conditions were varied in these experiments: energy of ions, surface temperature, working gas. Irradiations of tungsten WL 10 were executed in deuterium plasma at low ion energies (about 20 eV) and at 200 eV for temperatures below 340 K. Graphite RG-T was exposed at 1300 K. Elevated surface temperature (about 1050K) was also characteristic of experiments on tungsten sample under nitrogen plasma impact (simulated inter-ELMs condition). Surface microstructure modification has been observed and surface composition changes were found on the materials showing influence of high dose plasma irradiations on element redistribution in the near surface layers. (author)

  15. High frequency electric field spikes formed by electron beam-plasma interaction in plasma density gradients

    International Nuclear Information System (INIS)

    Gunell, H.; Loefgren, T.

    1997-02-01

    In the electron beam-plasma interaction at an electric double layer the beam density is much higher than in the classical beam-plasma experiments. The wave propagation takes place along the density gradient, that is present at the high potential side of the double layer. Such a case is studied experimentally by injecting the electron beam from a plane cathode, without any grids suppressing the gradient, and by particle simulations. The high frequency field concentrates in a sharp 'spike' with a half width of the order of one wavelength. The spike is found to be a standing wave surrounded by regions dominated by propagating waves. It forms at a position where its frequency is close to the local plasma frequency. The spike forms also when the electric field is well below the threshold for modulational instability, and long before a density cavity is formed in the simulations. Particle simulations reveal that, at the spike, there is a backward travelling wave that, when it is strongly damped, accelerates electrons back towards the cathode. In a simulation of a homogeneous plasma without the density gradient no spike is seen, and the wave is purely travelling instead of standing. 9 refs

  16. Genetic associations between fibrinogen and cognitive performance in three Scottish cohorts.

    Science.gov (United States)

    Marioni, Riccardo E; Deary, Ian J; Murray, Gordon D; Lowe, Gordon D O; Strachan, Mark W J; Luciano, Michelle; Houlihan, Lorna M; Gow, Alan J; Harris, Sarah E; Rumley, Ann; Stewart, Marlene C; Fowkes, F Gerry R; Price, Jackie F

    2011-09-01

    There is increasing evidence to suggest that elevated plasma levels of fibrinogen are associated with late-life cognitive performance. This study tested the association of single nucleotide polymorphisms in the fibrinogen α (FGA) and β (FGB) genes with cognitive performance. Data were analysed from three community-dwelling populations of older persons (>50 years) in central Scotland: the Aspirin for Asymptomatic Atherosclerosis (AAA) Trial (n = 2,091), the Edinburgh Type 2 Diabetes Study (ET2DS, n = 1,066), and the Lothian Birth Cohort 1936 (LBC1936, n = 1,091). Cognition was assessed using a battery of five, seven, and four psychometric tests, respectively. This information was used to derive a general cognitive factor. Weakly significant associations were found between the rs4220 (FGB), and rs2227412 (FGB) SNPs and a single test of cognitive performance in the AAA Trial (p determinant of late-life cognitive performance and justify further attempts at replication in older persons.

  17. Use of labelled fibrinogen for the detection of phlebitis

    International Nuclear Information System (INIS)

    Serradimigni, A.; Mathieu, P.; Leonetti, J.; Sacerdote, P.; Bory, M.; Djiane, P.; Egre, A.

    The value of 125 I-labelled fibrinogen as a diagnostic tool in the detection of deep vein thrombosis is discussed. The results are compared to those obtained with phlebography and with the clinical symptomatology. The technical problems are described: examination method and interpretation [fr

  18. Study of some parameters of the fibrinogen - fibrin transformation reaction

    International Nuclear Information System (INIS)

    Hollard, D.; Suscillon, M.; Marcille, G.; Rambaud, F.; Baloyan, M.

    1966-01-01

    The authors studied the action of some parameters on the reaction of transformation fibrinogen-fibrin. The five parameters studied are: the concentration of substratum: a certain quantity of enzyme determines an optimum quantity of fibrinogen; the concentration of enzyme: a certain quantity of substratum defines an optimum quantity of enzyme, beyond which the excess of enzyme is unable to act, the substratum being saturated by the enzyme; the concentration of Ca ions: between 0,07 and 0,10 mg of Ca by mg of fibrinogen, the reaction appears with a great speed. Between 0,02 and 0,40 mg of Ca by mg of fibrinogen the fibrin stabilisation is possible, the FSF can act only inside the definite bounds; the ph of the solution: the reaction of the transformation appears with its maximum intensity on physiological ph, the polymerisation is not possible on acid ph; the temperature has an effect which could not really be verified owing to the fact that the technical realisation is difficult. (author) [fr

  19. 21 CFR 864.7340 - Fibrinogen determination system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fibrinogen determination system. 864.7340 Section 864.7340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7340...

  20. Evaluation of the Characteristics of the Adsorption of Fibrinogen ...

    African Journals Online (AJOL)

    ... with calcium and magnesium ions increased the amount of fibrinogen adsorbed onto it as against treatment with potassium ion (a monovalent ion). Electrostatic attraction on the surface of the treated HAP and hydrogen are responsible for the adsorption. The results are useful in fabricating bone and teeth implants that are ...

  1. Preparation and quality control of fibrinogen 99mTc

    International Nuclear Information System (INIS)

    Noto, M.G.; Rabiller, Graciela; Garrie Faget, Claudio; Fisman, Carlos; Manzini, Alberto

    1987-01-01

    A method of fibrinogen preparation is presented in order to label it with 99m Tc employing Sn as reducing agent in alkaline medium. Purity controls by chromatography, coagulation in rabbits and biodistribution in rats were performed. It is concluded that optimal time incubation is between 22 and 23 hs. (M.E.L.) [es

  2. High levels of circulating triiodothyronine induce plasma cell differentiation.

    Science.gov (United States)

    Bloise, Flavia Fonseca; Oliveira, Felipe Leite de; Nobrega, Alberto Félix; Vasconcellos, Rita; Cordeiro, Aline; Paiva, Luciana Souza de; Taub, Dennis D; Borojevic, Radovan; Pazos-Moura, Carmen Cabanelas; Mello-Coelho, Valéria de

    2014-03-01

    The effects of hyperthyroidism on B-cell physiology are still poorly known. In this study, we evaluated the influence of high-circulating levels of 3,5,3'-triiodothyronine (T3) on bone marrow, blood, and spleen B-cell subsets, more specifically on B-cell differentiation into plasma cells, in C57BL/6 mice receiving daily injections of T3 for 14 days. As analyzed by flow cytometry, T3-treated mice exhibited increased frequencies of pre-B and immature B-cells and decreased percentages of mature B-cells in the bone marrow, accompanied by an increased frequency of blood B-cells, splenic newly formed B-cells, and total CD19(+)B-cells. T3 administration also promoted an increase in the size and cellularity of the spleen as well as in the white pulp areas of the organ, as evidenced by histological analyses. In addition, a decreased frequency of splenic B220(+) cells correlating with an increased percentage of CD138(+) plasma cells was observed in the spleen and bone marrow of T3-treated mice. Using enzyme-linked immunospot assay, an increased number of splenic immunoglobulin-secreting B-cells from T3-treated mice was detected ex vivo. Similar results were observed in mice immunized with hen egg lysozyme and aluminum adjuvant alone or together with treatment with T3. In conclusion, we provide evidence that high-circulating levels of T3 stimulate plasma cytogenesis favoring an increase in plasma cells in the bone marrow, a long-lived plasma cell survival niche. These findings indicate that a stimulatory effect on plasma cell differentiation could occur in untreated patients with Graves' disease.

  3. Resistive wall mode stabilization in slowly rotating high beta plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Reimerdes, H [Columbia University, New York, NY 10027 (United States); Garofalo, A M [Columbia University, New York, NY 10027 (United States); Okabayashi, M [Princeton Plasma Physics Laboratory, Princeton, NJ 08543-0451 (United States); Strait, E J [General Atomics, San Diego, CA 92186-5608 (United States); Betti, R [University of Rochester, Rochester, NY 14627 (United States); Chu, M S [General Atomics, San Diego, CA 92186-5608 (United States); Hu, B [University of Rochester, Rochester, NY 14627 (United States); In, Y [FAR-TECH, Inc., San Diego, CA 92121 (United States); Jackson, G L [General Atomics, San Diego, CA 92186-5608 (United States); La Haye, R J [General Atomics, San Diego, CA 92186-5608 (United States); Lanctot, M J [Columbia University, New York, NY 10027 (United States); Liu, Y Q [Chalmers University of Technology, S-412 96 Goeteborg (Sweden); Navratil, G A [Columbia University, New York, NY 10027 (United States); Solomon, W M [Princeton Plasma Physics Laboratory, Princeton, NJ 08543-0451 (United States); Takahashi, H [Princeton Plasma Physics Laboratory, Princeton, NJ 08543-0451 (United States); Groebner, R J [General Atomics, San Diego, CA 92186-5608 (United States)

    2007-12-15

    DIII-D experiments show that the resistive wall mode (RWM) can remain stable in high {beta} scenarios despite a low net torque from nearly balanced neutral beam injection heating. The minimization of magnetic field asymmetries is essential for operation at the resulting low plasma rotation of less than 20 krad s{sup -1} (measured with charge exchange recombination spectroscopy using C VI emission) corresponding to less than 1% of the Alfven velocity or less than 10% of the ion thermal velocity. In the presence of n = 1 field asymmetries the rotation required for stability is significantly higher and depends on the torque input and momentum confinement, which suggests that a loss of torque-balance can lead to an effective rotation threshold above the linear RWM stability threshold. Without an externally applied field the measured rotation can be too low to neglect the diamagnetic rotation. A comparison of the instability onset in plasmas rotating with and against the direction of the plasma current indicates the importance of the toroidal flow driven by the radial electric field in the stabilization process. Observed rotation thresholds are compared with predictions for the semi-kinetic damping model, which generally underestimates the rotation required for stability. A more detailed modeling of kinetic damping including diamagnetic and precession drift frequencies can lead to stability without plasma rotation. However, even with corrected error fields and fast plasma rotation, plasma generated perturbations, such as edge localized modes, can nonlinearly destabilize the RWM. In these cases feedback control can increase the damping of the magnetic perturbation and is effective in extending the duration of high {beta} discharges.

  4. High quality ceramic coatings sprayed by high efficiency hypersonic plasma spraying gun

    International Nuclear Information System (INIS)

    Zhu Sheng; Xu Binshi; Yao JiuKun

    2005-01-01

    This paper introduced the structure of the high efficiency hypersonic plasma spraying gun and the effects of hypersonic plasma jet on the sprayed particles. The optimised spraying process parameters for several ceramic powders such as Al 2 O 3 , Cr 2 O 3 , ZrO 2 , Cr 3 C 2 and Co-WC were listed. The properties and microstructure of the sprayed ceramic coatings were investigated. Nano Al 2 O 3 -TiO 2 ceramic coating sprayed by using the high efficiency hypersonic plasma spraying was also studied. Compared with the conventional air plasma spraying, high efficiency hypersonic plasma spraying improves greatly the ceramic coatings quality but at low cost. (orig.)

  5. Immunohistochemical Localization of Fibrinogen C Domain Containing 1 on Epithelial and Mucosal Surfaces in Human Tissues

    DEFF Research Database (Denmark)

    von Huth, Sebastian; Moeller, Jesper B; Schlosser, Anders

    2018-01-01

    Fibrinogen C domain containing 1 (FIBCD1) is a transmembrane receptor that binds chitin and other acetylated compounds with high affinity. FIBCD1 has previously been shown to be present in the epithelium of the gastrointestinal tract. In the present study, we performed a detailed analysis...... high expression of FIBCD1 and also mesodermal-derived cells in the genitourinary system and ectodermal-derived epidermis and sebaceous glands cells expressed FIBCD1. In some columnar epithelial cells, for example, in the salivary gland and gall bladder, the FIBCD1 expression was clearly polarized...

  6. Transient Plasma Photonic Crystals for High-Power Lasers.

    Science.gov (United States)

    Lehmann, G; Spatschek, K H

    2016-06-03

    A new type of transient photonic crystals for high-power lasers is presented. The crystal is produced by counterpropagating laser beams in plasma. Trapped electrons and electrically forced ions generate a strong density grating. The lifetime of the transient photonic crystal is determined by the ballistic motion of ions. The robustness of the photonic crystal allows one to manipulate high-intensity laser pulses. The scheme of the crystal is analyzed here by 1D Vlasov simulations. Reflection or transmission of high-power laser pulses are predicted by particle-in-cell simulations. It is shown that a transient plasma photonic crystal may act as a tunable mirror for intense laser pulses. Generalizations to 2D and 3D configurations are possible.

  7. High density plasma via hole etching in SiC

    International Nuclear Information System (INIS)

    Cho, H.; Lee, K.P.; Leerungnawarat, P.; Chu, S.N.G.; Ren, F.; Pearton, S.J.; Zetterling, C.-M.

    2001-01-01

    Throughwafer vias up to 100 μm deep were formed in 4H-SiC substrates by inductively coupled plasma etching with SF 6 /O 2 at a controlled rate of ∼0.6 μm min-1 and use of Al masks. Selectivities of >50 for SiC over Al were achieved. Electrical (capacitance-voltage: current-voltage) and chemical (Auger electron spectroscopy) analysis techniques showed that the etching produced only minor changes in reverse breakdown voltage, Schottky barrier height, and near surface stoichiometry of the SiC and had high selectivity over common frontside metallization. The SiC etch rate was a strong function of the incident ion energy during plasma exposure. This process is attractive for power SiC transistors intended for high current, high temperature applications and also for SiC micromachining

  8. High-frequency underwater plasma discharge application in antibacterial activity

    International Nuclear Information System (INIS)

    Ahmed, M. W.; Choi, S.; Lyakhov, K.; Shaislamov, U.; Mongre, R. K.; Jeong, D. K.; Suresh, R.; Lee, H. J.

    2017-01-01

    Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli (E. coli) by generating high-frequency, high-voltage, oxygen (O_2) injected and hydrogen peroxide (H_2O_2) added discharge in water was achieved. The effect of H_2O_2 dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H_2O_2 addition with O_2 injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population on the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH"•, H, and O). Interestingly, the results demonstrated that O_2 injected and H_2O_2 added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.

  9. High-frequency underwater plasma discharge application in antibacterial activity

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, M. W.; Choi, S.; Lyakhov, K.; Shaislamov, U. [Jeju National University, Department of Nuclear and Energy Engineering (Korea, Republic of); Mongre, R. K.; Jeong, D. K. [Jeju National University, Faculty of Biotechnology (Korea, Republic of); Suresh, R.; Lee, H. J., E-mail: hjlee@jejunu.ac.kr [Jeju National University, Department of Nuclear and Energy Engineering (Korea, Republic of)

    2017-03-15

    Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli (E. coli) by generating high-frequency, high-voltage, oxygen (O{sub 2}) injected and hydrogen peroxide (H{sub 2}O{sub 2}) added discharge in water was achieved. The effect of H{sub 2}O{sub 2} dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H{sub 2}O{sub 2} addition with O{sub 2} injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population on the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH{sup •}, H, and O). Interestingly, the results demonstrated that O{sub 2} injected and H{sub 2}O{sub 2} added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.

  10. Effects of carprofen and meloxicam on C-reactive protein, ceruloplasmin, and fibrinogen concentrations in dogs undergoing ovariohysterectomy.

    Science.gov (United States)

    Kum, Cavit; Voyvoda, Huseyin; Sekkin, Selim; Karademir, Umit; Tarimcilar, Tugrul

    2013-10-01

    To evaluate the effects of perioperative oral administration of carprofen and meloxicam on concentrations of 3 acute-phase proteins in dogs undergoing elective ovariohysterectomy (OVH). 18 healthy adult anestrous female dogs undergoing elective OVH. Dogs were allocated to 3 groups (6 dogs/group). A placebo treatment, carprofen (2.0 mg/kg), or meloxicam (0.2 mg/kg) was orally administered to the dogs of the respective groups. The initial doses were administered 30 minutes before premedication prior to OVH; additional doses were administered once daily for 4 days after surgery. Blood samples were collected 45 minutes before premedication and 4, 8, 12, 24, 36, 48, 72, 96, and 120 hours after the end of OVH; samples were used for measurement of total WBC and neutrophil counts and concentrations of C-reactive protein (CRP), ceruloplasmin, and fibrinogen. Values did not differ significantly among groups for WBC and neutrophil counts, serum concentrations of CRP and ceruloplasmin, and plasma concentrations of fibrinogen. Concentrations of all inflammatory markers, except serum ceruloplasmin, increased significantly following OVH, but in a similar manner for each group. No significant changes were detected in serum ceruloplasmin concentrations over time. Perioperative administration of both carprofen and meloxicam did not significantly affect the concentrations of CRP, ceruloplasmin, and fibrinogen in dogs undergoing OVH. Thus, use of carprofen or meloxicam should not affect clinical interpretation of results for these 3 acute-phase proteins.

  11. High-order harmonics generation from overdense plasmas

    International Nuclear Information System (INIS)

    Quere, F.; Thaury, C.; Monot, P.; Martin, Ph.; Geindre, J.P.; Audebert, P.; Marjoribanks, R.

    2006-01-01

    Complete test of publication follows. When an intense laser beam reflects on an overdense plasma generated on a solid target, high-order harmonics of the incident laser frequency are observed in the reflected beam. This process provides a way to produce XUV femtosecond and attosecond pulses in the μJ range from ultrafast ultraintense lasers. Studying the mechanisms responsible for this harmonic emission is also of strong fundamental interest: just as HHG in gases has been instrumental in providing a comprehensive understanding of basic intense laser-atom interactions, HHG from solid-density plasmas is likely to become a unique tool to investigate many key features of laser-plasma interactions at high intensities. We will present both experimental and theoretical evidence that two mechanisms contribute to this harmonic emission: - Coherent Wake Emission: in this process, harmonics are emitted by plasma oscillations in te overdense plasma, triggered in the wake of jets of Brunel electrons generated by the laser field. - The relativistic oscillating mirror: in this process, the intense laser field drives a relativistic oscillation of the plasma surface, which in turn gives rise to a periodic phase modulation of the reflected beam, and hence to the generation of harmonics of the incident frequency. Left graph: experimental harmonic spectrum from a polypropylene target, obtained with 60 fs laser pulses at 10 19 W/cm 2 , with a very high temporal contrast (10 10 ). The plasma frequency of this target corresponds to harmonics 15-16, thus excluding the CWE mechanism for the generation of harmonics of higher orders. Images on the right: harmonic spectra from orders 13 et 18, for different distances z between the target and the best focus. At the highest intensity (z=0), harmonics emitted by the ROM mechanism are observed above the 15th order. These harmonics have a much smaller spectral width then those due to CWE (below the 15th order). These ROM harmonics vanish as soon

  12. A cold plasma plume with a highly conductive liquid electrode

    International Nuclear Information System (INIS)

    Chen Guangliang; Chen Wenxing; Chen Shihua; Yang Size

    2008-01-01

    A cold dielectric barrier discharge (DBD) plasma plume with one highly conductive liquid electrode has been developed to treat thermally sensitive materials, and its preliminary discharging characteristics have been studied. The averaged electron temperature and density is estimated to be 0.6eV and 10 11 /cm 3 , respectively. The length of plasma plume can reach 5 cm with helium gas (He), and the conductivity of the outer electrode affects the plume length obviously. This plasma plume could be touched by bare hand without causing any burning or painful sensation, which may provide potential application for safe aseptic skin care. Moreover, the oxidative particles (e.g., OH, O * , O 3 ) in the downstream oxygen (O2) gas of the plume have been applied to treat the landfill leachate. The results show that the activated O 2 gas can degrade the landfill leachate effectively, and the chemical oxygen demand (COD), conductivity, biochemical oxygen demand (BOD), and suspended solid (SS) can be decreased by 52%, 57%, 76% and 92%, respectively. (fluids, plasmas and electric discharges)

  13. High performance liquid chromatographic determination of glucosamine in rat plasma.

    Science.gov (United States)

    Aghazadeh-Habashi, Ali; Sattari, Saeed; Pasutto, Franco; Jamali, Fakhreddin

    2002-01-01

    A high performance liquid chromatographic method was developed for the determination of glucosamine (GlcN) in rat plasma. Internal standard, galactosamine, was added to 100 micro L of plasma containing GlcN followed by precipitation of plasma proteins with acetonitrile. Evaporation of the decanted supernatant solution was accelerated by the addition of methanol. GlcN was derivatized by addition of a solution containing 1-naphthyl isothiocyanate. Sample cleanup included passage through an anion exchange cartridge. Analysis was accomplished by injection of 0.1 mL of the sample solution into an isocratic HPLC system consisting of a C18 column, a mobile phase of acetonitrile: water: acetic acid: triethylamine (4.5: 95.5:0.1:0.05), a flow rate of 0.9 mL/min, and a UV detector set at 254 nm. Galactosamine and GlcN appeared 26 and 29 min post-injection, respectively. The assay was linear over the range of 1.25-400 micro g/mL (CV<10%) with a detection limit of 0.63 microg/mL and a limit of quantification of 1.25 microg/mL. The method was applied to the determination of GlcN in rat plasma after oral administration of 350 mg/kg of GlcN hydrochloride. The present assay is specific, sensitive, precise, and accurate and is suitable for pharmacokinetic studies.

  14. Behaviour of homologous 125I fibrinogen after thrombin and ancrod infusion in rabbits

    International Nuclear Information System (INIS)

    Setter, R.

    1977-01-01

    The behaviour of radioactively labelled fibrinogen after infusion of thrombin or ancrod is investigated. Common factors and differences in the behaviour of fibrinogen after infusion of these two enzymes, which act proteolytically on the fibrinogen, are dealt with. Rabbits received an i.v. injection of homologous 125 I-fibrinogen 3 days before ancrod or thrombin infusion. On the day of the experiments, one group of animals received an ancrod infusion (1.5 U/kg body weight for 30 minutes), the other a thrombin infusion (600 U/kg body weight for 60 minutes). Intravenous ancrod and thrombin infusions lowered the fibrinogen level to 30% or 50% of the initial value due to intravascular coagulation. About 50% of the 125 I fibrinogen was transformed after ancrod exposure into a non-coagulating fraction of fibrinogen derivatives which produces no fibrinolytic decomposition products. (orig./AJ) [de

  15. High speed manyframe optical methods for plasma diagnostics

    International Nuclear Information System (INIS)

    Erokhin, A.A.; Shikanov, A.S.; Sklizkov, G.V.; Zakharenkov, Yu.A.; Zorev, N.N.

    1979-01-01

    A complex of active optical plasma and strong ionized shock wave diagnostics is described. The complex consisted of a specially developed high speed manyframe systems of shadow, schlieren and interferometric photography. The comparison of results obtained by a simultaneous registration of investigated object by means of different optical methods allowed us to determine optimal employment range for the methods. The sensitivity, temporal and space resolution of each optical method under conditions of high probe radiation refraction are discussed. The application boundaries of these methods for ionized shock wave investigation were found to depend on the shock wave front width. The methods described were used for the study of laser-produced plasma phenomena, occuring in the experiments on powerful nine-channel laser installation ''Kalmar''. (author)

  16. Simulation of plasma loading of high-pressure RF cavities

    Science.gov (United States)

    Yu, K.; Samulyak, R.; Yonehara, K.; Freemire, B.

    2018-01-01

    Muon beam-induced plasma loading of radio-frequency (RF) cavities filled with high pressure hydrogen gas with 1% dry air dopant has been studied via numerical simulations. The electromagnetic code SPACE, that resolves relevant atomic physics processes, including ionization by the muon beam, electron attachment to dopant molecules, and electron-ion and ion-ion recombination, has been used. Simulations studies have been performed in the range of parameters typical for practical muon cooling channels.

  17. Simulation of plasma loading of high-pressure RF cavities

    Energy Technology Data Exchange (ETDEWEB)

    Yu, K. [Brookhaven National Lab. (BNL), Upton, NY (United States). Computational Science Initiative; Samulyak, R. [Brookhaven National Lab. (BNL), Upton, NY (United States). Computational Science Initiative; Stony Brook Univ., NY (United States). Dept. of Applied Mathematics and Statistics; Yonehara, K. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Freemire, B. [Northern Illinois Univ., DeKalb, IL (United States)

    2018-01-11

    Muon beam-induced plasma loading of radio-frequency (RF) cavities filled with high pressure hydrogen gas with 1% dry air dopant has been studied via numerical simulations. The electromagnetic code SPACE, that resolves relevant atomic physics processes, including ionization by the muon beam, electron attachment to dopant molecules, and electron-ion and ion-ion recombination, has been used. Simulations studies have also been performed in the range of parameters typical for practical muon cooling channels.

  18. Analytic analysis on asymmetrical micro arcing in high plasma potential RF plasma systems

    International Nuclear Information System (INIS)

    Yin, Y; McKenzie, D R; Bilek, M M M

    2006-01-01

    We report experimental and analytical results on asymmetrical micro arcing in a RF (radio frequency) plasma. Micro arcing, resulting from high plasma potential, in RF plasma was found to occur only on the grounded electrode for a variety of electrode and surface configurations. The analytic derivation was based on a simple RF time-dependent Child-Langmuir sheath model and electric current continuity. We found that the minimum potential difference in one RF period across the grounded electrode sheath depends on the area ratio of the grounded electrode to the powered electrode. As the area ratio increases, the minimum potential difference across a sheath increases for the grounded electrode but not for the RF powered electrode. We showed that discharge time in micro arcing is more than 100 RF periods; thus the presence of a continuous high electric field in one RF cycle results in micro arcing on the grounded electrode. However, the minimum potential difference in one RF period across the powered electrode sheath is always small so that it prevents micro arcing occurring even though the average sheath voltage can be large. This simple analytic model is consistent with particle-in-cell simulation results

  19. Collisional and radiative processes in high-pressure discharge plasmas

    Science.gov (United States)

    Becker, Kurt H.; Kurunczi, Peter F.; Schoenbach, Karl H.

    2002-05-01

    Discharge plasmas at high pressures (up to and exceeding atmospheric pressure), where single collision conditions no longer prevail, provide a fertile environment for the experimental study of collisions and radiative processes dominated by (i) step-wise processes, i.e., the excitation of an already excited atomic/molecular state and by (ii) three-body collisions leading, for instance, to the formation of excimers. The dominance of collisional and radiative processes beyond binary collisions involving ground-state atoms and molecules in such environments allows for many interesting applications of high-pressure plasmas such as high power lasers, opening switches, novel plasma processing applications and sputtering, absorbers and reflectors for electromagnetic waves, remediation of pollutants and waste streams, and excimer lamps and other noncoherent vacuum-ultraviolet light sources. Here recent progress is summarized in the use of hollow cathode discharge devices with hole dimensions in the range 0.1-0.5 mm for the generation of vacuum-ultraviolet light.

  20. Plasma polymerized high energy density dielectric films for capacitors

    Science.gov (United States)

    Yamagishi, F. G.

    1983-01-01

    High energy density polymeric dielectric films were prepared by plasma polymerization of a variety of gaseous monomers. This technique gives thin, reproducible, pinhole free, conformable, adherent, and insoluble coatings and overcomes the processing problems found in the preparation of thin films with bulk polymers. Thus, devices are prepared completely in a vacuum environment. The plasma polymerized films prepared all showed dielectric strengths of greater than 1000 kV/cm and in some cases values of greater than 4000 kV/cm were observed. The dielectric loss of all films was generally less than 1% at frequencies below 10 kHz, but this value increased at higher frequencies. All films were self healing. The dielectric strength was a function of the polymerization technique, whereas the dielectric constant varied with the structure of the starting material. Because of the thin films used (thickness in the submicron range) surface smoothness of the metal electrodes was found to be critical in obtaining high dielectric strengths. High dielectric strength graft copolymers were also prepared. Plasma polymerized ethane was found to be thermally stable up to 150 C in the presence of air and 250 C in the absence of air. No glass transitions were observed for this material.

  1. Radioiodine-fibrinogen test in the early diagnosis of venous thrombosis in the leg

    Energy Technology Data Exchange (ETDEWEB)

    Dahlgruen, H [Medizinische Hochschule Hannover (F.R. Germany). Dept. Radiologie

    1976-04-01

    As long as there is no satisfactory prophylaxis for thrombosis, the radioiodine-fibrinogen test is a good supplement for the supervision of patients with a 'high thrombosis risk' since the clinical symptomatology is not specific enough and phlebography cannot be used so extensively. The risk of hepatitis can be reduced when the selection of spenders is large enough. As a radionuclide, /sup 125/iodine does not appear to be any less effective than /sup 131/iodine. The postoperative injection is preferred to the preoperative injection.

  2. Time-dependent association between platelet-bound fibrinogen and the Triton X-100 insoluble cytoskeleton

    International Nuclear Information System (INIS)

    Peerschke, E.I.

    1991-01-01

    Previous studies indicated a correlation between the formation of EDTA-resistant (irreversible) platelet-fibrinogen interactions and platelet cytoskeleton formation. The present study explored the direct association of membrane-bound fibrinogen with the Triton X-100 insoluble cytoskeleton of aspirin-treated, gel-filtered platelets, activated but not aggregated with 20 mumol/L adenosine diphosphate (ADP) or 150 mU/mL human thrombin (THR) when bound fibrinogen had become resistant to dissociation by EDTA. Conversion of exogenous 125I-fibrinogen to fibrin was prevented by adding Gly-Pro-Arg and neutralizing THR with hirudin before initiating binding studies. After 60 minutes at 22 degrees C, the cytoskeleton of ADP-treated platelets contained 20% +/- 12% (mean +/- SD, n = 14) of membrane-bound 125I-fibrinogen, representing 10% to 50% of EDTA-resistant fibrinogen binding. The THR-activated cytoskeleton contained 45% +/- 15% of platelet bound fibrinogen, comprising 80% to 100% of EDTA-resistant fibrinogen binding. 125I-fibrinogen was not recovered with platelet cytoskeletons if binding was inhibited by the RGDS peptide, excess unlabeled fibrinogen, or disruption of the glycoprotein (GP) IIb-IIIa complex by EDTA-treatment. Both development of EDTA-resistant fibrinogen binding and fibrinogen association with the cytoskeleton were time dependent and reached maxima 45 to 60 minutes after fibrinogen binding to stimulated platelets. Although a larger cytoskeleton formed after platelet stimulation with thrombin as compared with ADP, no change in cytoskeleton composition was noted with development of EDTA-resistant fibrinogen binding

  3. Plasma-surface interactions under high heat and particle fluxes

    NARCIS (Netherlands)

    De Temmerman, G.; Bystrov, K.; Liu, F.; Liu, W.; Morgan, T.; Tanyeli, I.; van den Berg, M.; Xu, H.; Zielinski, J.

    2013-01-01

    The plasma-surface interactions expected in the divertor of a future fusion reactor are characterized by extreme heat and particle fluxes interacting with the plasma-facing surfaces. Powerful linear plasma generators are used to reproduce the expected plasma conditions and allow plasma-surface

  4. High density plasma heating in the Tokamak à configuration variable

    International Nuclear Information System (INIS)

    Curchod, L.

    2011-04-01

    The Tokamak à Configuration Variable (TCV) is a medium size magnetic confinement thermonuclear fusion experiment designed for the study of the plasma performances as a function of its shape. It is equipped with a high power and highly flexible electron cyclotron heating (ECH) and current drive (ECCD) system. Up to 3 MW of 2 nd harmonic EC power in ordinary (O 2 ) or extraordinary (X 2 ) polarization can be injected from TCV low-field side via six independently steerable launchers. In addition, up to 1.5 MW of 3 rd harmonic EC power (X 3 ) can be launched along the EC resonance from the top of TCV vacuum vessel. At high density, standard ECH and ECCD are prevented by the appearance of a cutoff layer screening the access to the EC resonance at the plasma center. As a consequence, less than 50% of TCV density operational domain is accessible to X 2 and X 3 ECH. The electron Bernstein waves (EBW) have been proposed to overcome this limitation. EBW is an electrostatic mode propagating beyond the plasma cutoff without upper density limit. Since it cannot propagate in vacuum, it has to be excited by mode conversion of EC waves in the plasma. Efficient electron Bernstein waves heating (EBH) and current drive (EBCD) were previously performed in several fusion devices, in particular in the W7-AS stellarator and in the MAST spherical tokamak. In TCV, the conditions for an efficient O-X-B mode conversion (i.e. a steep density gradient at the O 2 plasma cutoff) are met at the edge of high confinement (H-mode) plasmas characterized by the appearance of a pedestal in the electron temperature and density profiles. TCV experiments have demonstrated the first EBW coupling to overdense plasmas in a medium aspect-ratio tokamak via O-X-B mode conversion. This thesis work focuses on several aspects of ECH and EBH in low and high density plasmas. Firstly, the experimental optimum angles for the O-X-B mode conversion is successfully compared to the full-wave mode conversion calculation

  5. DNA-polymorphisms and plasma levels of vascular disease risk factors in Greenland Inuit--is there a relation with the low risk of cardiovascular disease in the Inuit?

    DEFF Research Database (Denmark)

    Maat, M de; Bladbjerg, E-M; Johansen, L G

    1999-01-01

    Greenland Inuit are a population with a low risk of cardiovascular disease. Recently, we stated that frequencies of potentially high risk alleles of the apolipoproteins, fibrinogen, factor V, glycoprotein IIIa and factor VII (FVII) genes have different allele frequencies in the Inuit when compared...... and CVD risk in Caucasian populations, but for other measures this was not the case (allele frequencies of the PAI-1 polymorphism, and plasma levels of fibrinogen, FVII and t-PA). In conclusion there are clear differences in genetic background and plasma levels of risk factors in Greenland Inuit compared......, aged 30-34 gamma. In addition, we compared the plasma levels of these factors and those of C-reactive protein (CRP) and D-Dimer in Inuit and in Danes, comparable for age and gender. Frequencies (f) were assessed of the alleles that are known as the potential high risk alleles in Caucasians...

  6. High-performance liquid chromatographic radioenzymatic assay for plasma catecyholamines

    International Nuclear Information System (INIS)

    Klaniecki, T.S.; Corder, C.N.; McDonald, R.H. Jr.; Feldman, J.A.

    1977-01-01

    A new assay method for plasma catecholamimes (CA) requiring only 50 μl has been developed, which uses high performance liquid chromatography (HPLC). The norepinephrine (NE), dopamine (D), and epinephrine (E) compounds found in plasma are radioactively o-methylated with S-[methyl- 3 H]-adenosyl-L-methionine ( 3 H-SAM) 3 H-SAM by the reaction of catechol-o-methyl transferase (COMT). The reaction is terminated and a standard mixture of nonradioactive o-methylated analogues of NE, D, and E is added to act as a carrier. Following separation by HPLC, the D,L-normetanephrine (NMN), 3-methoxy-4-hydroxyphenylethyl-amine or 3-methoxytyramine (3-MOT), and metanephrine (MN) radioactive peaks are collected which represent NE, D, and E, respectively. Then MNM and MN are oxidized to vanillin, and 3-MOT is acetylated. The products are subsequently separated by solvent extraction. This is necessary in order to avoid high radioactive blanks and to allow quantitation of the radioactivity by liquid scintillation spectrometry. The mean supine levels of NE, D, and E in normal subjects were respectively 182, 33, and 87 pg/ml of plasma. Similar assays on patients with pheochromocytoma revealed 797, 80, and 470 pg/ml

  7. Three plasma metabolite signatures for diagnosing high altitude pulmonary edema

    Science.gov (United States)

    Guo, Li; Tan, Guangguo; Liu, Ping; Li, Huijie; Tang, Lulu; Huang, Lan; Ren, Qian

    2015-10-01

    High-altitude pulmonary edema (HAPE) is a potentially fatal condition, occurring at altitudes greater than 3,000 m and affecting rapidly ascending, non-acclimatized healthy individuals. However, the lack of biomarkers for this disease still constitutes a bottleneck in the clinical diagnosis. Here, ultra-high performance liquid chromatography coupled with Q-TOF mass spectrometry was applied to study plasma metabolite profiling from 57 HAPE and 57 control subjects. 14 differential plasma metabolites responsible for the discrimination between the two groups from discovery set (35 HAPE subjects and 35 healthy controls) were identified. Furthermore, 3 of the 14 metabolites (C8-ceramide, sphingosine and glutamine) were selected as candidate diagnostic biomarkers for HAPE using metabolic pathway impact analysis. The feasibility of using the combination of these three biomarkers for HAPE was evaluated, where the area under the receiver operating characteristic curve (AUC) was 0.981 and 0.942 in the discovery set and the validation set (22 HAPE subjects and 22 healthy controls), respectively. Taken together, these results suggested that this composite plasma metabolite signature may be used in HAPE diagnosis, especially after further investigation and verification with larger samples.

  8. Statistical approach for calculating opacities of high-Z plasmas

    International Nuclear Information System (INIS)

    Nishikawa, Takeshi; Nakamura, Shinji; Takabe, Hideaki; Mima, Kunioki

    1992-01-01

    For simulating the X-ray radiation from laser produced high-Z plasma, an appropriate atomic modeling is necessary. Based on the average ion model, we have used a rather simple atomic model for opacity calculation in a hydrodynamic code and obtained a fairly good agreement with the experiment on the X-ray spectra from the laser-produced plasmas. We have investigated the accuracy of the atomic model used in the hydrodynamic code. It is found that transition energies of 4p-4d, 4d-4f, 4p-5d, 4d-5f and 4f-5g, which are important in laser produced high-Z plasma, can be given within an error of 15 % compared to the values by the Hartree-Fock-Slater (HFS) calculation and their oscillator strengths obtained by HFS calculation vary by a factor two according to the difference of charge state. We also propose a statistical method to carry out detail configuration accounting for electronic state by use of the population of bound electrons calculated with the average ion model. The statistical method is relatively simple and provides much improvement in calculating spectral opacities of line radiation, when we use the average ion model to determine electronic state. (author)

  9. Shear and bulk viscosity of high-temperature gluon plasma

    Science.gov (United States)

    Zhang, Le; Hou, De-Fu

    2018-05-01

    We calculate the shear viscosity (η) and bulk viscosity (ζ) to entropy density (s) ratios η/s and ζ/s of a gluon plasma system in kinetic theory, including both the elastic {gg}≤ftrightarrow {gg} forward scattering and the inelastic soft gluon bremsstrahlung {gg}≤ftrightarrow {ggg} processes. Due to the suppressed contribution to η and ζ in the {gg}≤ftrightarrow {gg} forward scattering and the effective g≤ftrightarrow {gg} gluon splitting, Arnold, Moore and Yaffe (AMY) and Arnold, Dogan and Moore (ADM) have got the leading order computations for η and ζ in high-temperature QCD matter. In this paper, we calculate the correction to η and ζ in the soft gluon bremsstrahlung {gg}≤ftrightarrow {ggg} process with an analytic method. We find that the contribution of the collision term from the {gg}≤ftrightarrow {ggg} soft gluon bremsstrahlung process is just a small perturbation to the {gg}≤ftrightarrow {gg} scattering process and that the correction is at ∼5% level. Then, we obtain the bulk viscosity of the gluon plasma for the number-changing process. Furthermore, our leading-order result for bulk viscosity is the formula \\zeta \\propto \\tfrac{{α }s2{T}3}{ln}{α }s-1} in high-temperature gluon plasma. Supported by Ministry of Science and Technology of China (MSTC) under the “973” Project (2015CB856904(4)) and National Natural Science Foundation of China (11735007, 11521064)

  10. Diagnostic value of radioactive fibrinogen and rheography in phlebitis

    International Nuclear Information System (INIS)

    Serradimigni, A.; Bory, M.; Djiane, P.; Sacerdote, P.; Mathieu, P.; Leonetti, J.; Egre, A.

    1975-01-01

    In 212 patients the diagnostic value of radioactive fibrinogen and rheography in deep venous thrombosis in the leg was studied by comparing the results from these two methods with phlebography. Radioactive fibrinogen seems the better means of diagnosis in early distal phlebitis. However, the method is expensive, the radioactive substance can only be manipulated in certain specialized centers, and is useless in the presence of hematoma. Rheography is less expensive, more easily manipulated, yet less sensitive as only proximal phlebitis can be detected especially when completely occlusive. In addition, active patient cooperation is necessary. The time needed to realize the two methods is a major obstacle; however, they can be fruitful if integrated into a specialized department for the diagnosis and treatment of thrombo-embolic disease [fr

  11. The role of fibrinogen and haemostatic assessment in postpartum haemorrhage

    DEFF Research Database (Denmark)

    Wikkelsø, Anne Juul

    2015-01-01

    Pregnancy is a state of hypercoagulobility that might be an evolutionary way of protecting parturients from exsanguination following child birth. Observational studies suggest an association between a low level of fibrinogen (coagulation factor I) at the start of postpartum haemorrhage (PPH....... Paper III was based on two national Danish registries evaluating the predictability of postpartum blood transfusion. Prediction was found difficult. However, retained placental parts seemed to be the strongest predictor. Since this diagnosis is made very late and often in association with the onset...... describes the protocol for a RCT of early fibrinogen supplementation in women with severe postpartum haemorrhage. Several practical, ethical and trial management challenges need to be addressed when conducting independent clinical research involving parturients with severe bleeding, placebo...

  12. Preparation of 99 sup(m)Tc labeled fibrinogen

    International Nuclear Information System (INIS)

    Almeida, M.A.T.M. de; Silva, C.P.G. da.

    1984-01-01

    A simple method for the preparation of 99 sup(m) TC labelled Fibrinogen using stannous chloride as reducing agent of 99 sup(m) TcO- 4 ion is presented. A sample of 20 mg of Fibrinogen is dissolved in 2 ml of buffer carbonate (pH=8) and 0.3 ml stannous chloride 0.2% is added. A sterile solution of sodium pertechnetate 99 sup(m) Tc eluted from a Mo-Tc generator is immediately added. The mixture rests for 30 minutes and after this period, the obtained yield is about 70%. The lyophilized kits also presented a yield of 70%, being therefore suitable for medical applications. (Author) [pt

  13. Dynamic behaviour of the high confinement mode of fusion plasmas

    International Nuclear Information System (INIS)

    Zohm, H.

    1995-05-01

    This paper describes the dynamic behaviour of the High Confinement mode (H-mode) of fusion plasmas, which is one of the most promising regimes of enhanced energy confinement in magnetic fusion research. The physics of the H-mode is not yet fully understood, and the detailed behaviour is complex. However, we establish a simple physics picture of the phenomenon. Although a first principles theory of the anomalous transport processes in a fusion plasma has not yet been given, we show that within the picture developed here, it is possible to describe the dynamic behaviour of the H-mode, namely the dynamics of the L-H transition and the occurrence of edge localized modes (ELMs). (orig.)

  14. High-throughput anisotropic plasma etching of polyimide for MEMS

    International Nuclear Information System (INIS)

    Bliznetsov, Vladimir; Manickam, Anbumalar; Ranganathan, Nagarajan; Chen, Junwei

    2011-01-01

    This note describes a new high-throughput process of polyimide etching for the fabrication of MEMS devices with an organic sacrificial layer approach. Using dual frequency superimposed capacitively coupled plasma we achieved a vertical profile of polyimide with an etching rate as high as 3.5 µm min −1 . After the fabrication of vertical structures in a polyimide material, additional steps were performed to fabricate structural elements of MEMS by deposition of a SiO 2 layer and performing release etching of polyimide. (technical note)

  15. Very high energy probes of the quark-gluon plasma

    International Nuclear Information System (INIS)

    Ludlam, T.; Paige, F.; Madansky, L.

    1984-01-01

    Among the penetrating probes of nuclear matter the most frequently discussed have been those which involve the detection of photons or leptons with m/sub T/ approx. = P/sub T/ < 3 GeV. This is the expected range of emission from a hot, thermalized plasma of quarks and gluons. The suggestion has been made that in very high energy collisions of nuclei the properties of high P/sub T/ jets may also reflect the characteristics of the nuclear medium through which the parent partons have propagated just after the collision. In this note we expand on the possible uses of such a probe

  16. Plasma-Assisted Chemistry in High-Speed Flow

    International Nuclear Information System (INIS)

    Leonov, Sergey B.; Yarantsev, Dmitry A.; Napartovich, Anatoly P.; Kochetov, Igor V.

    2007-01-01

    Fundamental problems related to the high-speed combustion are analyzed. The result of plasma-chemical modeling is presented as a motivation of experimental activity. Numerical simulations of the effect of uniform non-equilibrium discharge on the premixed hydrogen and ethylene-air mixture in supersonic flow demonstrate an advantage of such a technique over a heating. Experimental results on multi-electrode non-uniform discharge maintenance behind wallstep and in cavity of supersonic flow are presented. The model test on hydrogen and ethylene ignition is demonstrated at direct fuel injection to low-temperature high-speed airflow

  17. 13. TOPICAL CONFERENCE ON HIGH TEMPERATURE PLASMA DIAGNOSTICS SCIENTIFIC PROGRAM

    International Nuclear Information System (INIS)

    Barnes, C.

    2000-01-01

    Electron cyclotron emission (ECE) has been employed as a standard electron temperature profile diagnostic on many tokamaks and stellarators, but most magnetically confined plasma devices cannot take advantage of standard ECE diagnostics to measure temperature. They are either overdense, operating at high density relative to the magnetic field (e.g. ω pe >> (Omega) ce in a spherical torus) or they have insufficient density and temperature to reach the blackbody condition (τ > 2). Electron Bernstein waves (EBWs) are electrostatic waves which can propagate in overdense plasmas and have a high optical thickness at the electron cyclotron resonance layers, as a result of their large K i . This talk reports on measurements of EBW emission on the CDX-U spherical torus, where B 0 ∼ 2 kG, e > ∼ 10 13 cm -3 and T e ∼ 10 - 200 eV. Results will be presented for both direct detection of EBWs and for mode-converted EBW emission. The EBW emission was absolutely calibrated and compared to the electron temperature profile measured by a multi-point Thomson scattering diagnostic. Depending on the plasma conditions, the mode-converted EBW radiation temperature was found to be ≤ T e and the emission source was determined to be radially localized at the electron cyclotron resonance layer. A Langmuir triple probe was employed to measure changes in edge density profile in the vicinity of the upper hybrid resonance where the mode conversion of the EBWs is expected to occur. Changes in the mode conversion efficiency may explain the observation of mode-converted EBW radiation temperatures below T e . Initial results suggest EBW emission and EBW heating are viable concepts for plasmas where ω pe >> (Omega) ce

  18. Clotting of mammalian fibrinogens by papain: A re-examination

    OpenAIRE

    Doolittle, RF

    2014-01-01

    © 2014 American Chemical Society. Papain has long been known to cause the gelation of mammalian fibrinogens. It has also been reported that papain-fibrin is insoluble in dispersing solvents like strong urea or sodium bromide solutions, similar to what is observed with thrombin-generated clots in the presence of factor XIIIa and calcium. In those old studies, both the gelation and subsequent clot stabilization were attributed to papain, although the possibility that the second step might be du...

  19. Plasma concentrations of extracellular matrix protein fibulin-1 are related to cardiovascular risk markers in chronic kidney disease and diabetes

    DEFF Research Database (Denmark)

    Scholze, Alexandra; Bladbjerg, Else-Marie; Sidelmann, Johannes J

    2013-01-01

    ABSTRACT: BACKGROUND: Fibulin-1 is one of a few extracellular matrix proteins present in blood in high concentrations. We aimed to define the relationship between plasma fibulin-1 levels and risk markers of cardiovascular disease. METHODS: Plasma fibulin-1 was determined in subjects with chronic...... to determine central hemodynamic and arterial stiffness indices. RESULTS: We observed a positive correlation of fibulin-1 levels with age (r = 0.38; p = 0.033), glycated hemoglobin (r = 0.80; p = 0.003), creatinine (r = 0.35; p = 0.045), and fibrinogen (r = 0.39; p = 0.027). Glomerular filtration rate...... and fibulin-1 were inversely correlated (r = -0.57; p = 0.022). There was a positive correlation between fibulin-1 and central pulse pressure (r = 0.44; p = 0.011) and central augmentation pressure (r = 0.55; p = 0.001). In a multivariable regression model, diabetes, creatinine, fibrinogen and central...

  20. Operational characteristics of the high flux plasma generator magnum-PSI

    NARCIS (Netherlands)

    Van Eck, H.J.N.; Abrams, T.; Van Den Berg, M.A.; Brons, S.D.N.; Van Eden, G.G.; Jaworski, M.A.; Kaita, R.; Van Der Meiden, H.J.; Morgan, T.W.; van de Pol, Marc J.; Scholten, J.; Smeets, P.H.M.; De Temmerman, G.; De Vries, P.C.; Zeijlmans Van Emmichoven, P.A.

    2014-01-01

    In Magnum-PSI (MAgnetized plasma Generator and NUMerical modeling for Plasma Surface Interactions), the high density, low temperature plasma of a wall stabilized dc cascaded arc is confined to a magnetized plasma beam by a quasi-steady state axial magnetic field up to 1.3 T. It aims at conditions

  1. Fibrinogen-binding and platelet-aggregation activities of a Lactobacillus salivarius septicaemia isolate are mediated by a novel fibrinogen-binding protein.

    Science.gov (United States)

    Collins, James; van Pijkeren, Jan-Peter; Svensson, Lisbeth; Claesson, Marcus J; Sturme, Mark; Li, Yin; Cooney, Jakki C; van Sinderen, Douwe; Walker, Alan W; Parkhill, Julian; Shannon, Oonagh; O'Toole, Paul W

    2012-09-01

    The marketplace for probiotic foods is burgeoning, measured in billions of euro per annum. It is imperative, however, that all bacterial strains are fully assessed for human safety. The ability to bind fibrinogen is considered a potential pathogenicity trait that can lead to platelet aggregation, serious medical complications, and in some instances, death. Here we examined strains from species frequently used as probiotics for their ability to bind human fibrinogen. Only one strain (CCUG 47825), a Lactobacillus salivarius isolate from a case of septicaemia, was found to strongly adhere to fibrinogen. Furthermore, this strain was found to aggregate human platelets at a level comparable to the human pathogen Staphylococcus aureus. By sequencing the genome of CCUG 47825, we were able to identify candidate genes responsible for fibrinogen binding. Complementing the genetic analysis with traditional molecular microbiological techniques enabled the identification of the novel fibrinogen receptor, CCUG_2371. Although only strain CCUG 47825 bound fibrinogen under laboratory conditions, homologues of the novel fibrinogen binding gene CCUG_2371 are widespread among L. salivarius strains, maintaining their potential to bind fibrinogen if expressed. We highlight the fact that without a full genetic analysis of strains for human consumption, potential pathogenicity traits may go undetected. © 2012 Blackwell Publishing Ltd.

  2. Laser-assisted fibrinogen bonding of umbilical vein grafts.

    Science.gov (United States)

    Oz, M C; Williams, M R; Souza, J E; Dardik, H; Treat, M R; Bass, L S; Nowygrod, R

    1993-06-01

    Despite success with autologous tissue welding, laser welding of synthetic vascular prostheses has not been possible. The graft material appears inert and fails to allow the collagen breakdown and electrostatic bonding that results in tissue welding. To develop a laser welding system for graft material, we repaired glutaraldehyde-tanned human umbilical cord vein graft incisions using laser-assisted fibrinogen bonding (LAFB) technology. Modified umbilical vein graft was incised transversely (1.2 cm). Incisions were repaired using sutures, laser energy alone, or LAFB. For LAFB, indocyanine green dye was mixed with human fibrinogen and the compound applied with forceps onto the weld site prior to exposure to 808 nm diode laser energy (power density 4.8 W/cm 2). Bursting pressures for sutured repairs (126.6 +/- 23.4 mm Hg) were similar to LAFB anastomoses (111.6 +/- 55.0 mm Hg). No evidence of collateral thermal injury to the graft material was noted. In vivo evaluation of umbilical graft bonding with canine arteries demonstrates that LAFB can reliably reinforce sutured anastomoses. The described system for bonding graft material with laser exposed fibrinogen may allow creation or reinforcement of vascular anastomoses in procedures where use of autologous tissue is not feasible.

  3. Clinical applications of Ga-67 DFO-DAS-fibrinogen

    International Nuclear Information System (INIS)

    Iio, Masahiro; Ohtake, Tohru; Nishikawa, Junichi; Watanabe, Toshiaki; Yasuhara, Hiroshi; Ohashi, Shigenobu; Takayama, Yutaka; Tada, Yusuke; Shirakawa, Motoaki

    1987-01-01

    Ga-67 DFO-DAS-fibrinogen scanning was performed in 15 patients to detect fresh arterial thrombus. Seven patients were preoperative cases of aortic aneurysm and eight were postoperative cases of graft bypass. Scanning was performed on the first and second days after the injection. Nine of 13 grafts in eight cases were visualized by 67 Ga-DFO-DAS-fibrinogen scan. Velour Dacron grafts were more strongly visualized compared with woven Dacron or Goatex. In three patients with aortic aneurysm in whom fresh thrombus was identified by operative findings, arterial thrombus was clearly visualized by 67 Ga-DFO-DAS-fibrinogen scan, whereas in three other patients with aortic aneurysm, thrombus was not visualized, although it was identified by other examinations. In one case, a marked accumulation was observed in the abdominal aorta, although no arterial thrombus was found at operation. This was thought to be an accumulation in a blood pool because it decreased on the second day. We think it important to observe the relative changes of accumulation. (author)

  4. A sensitive HPLC-MS/MS method for the simultaneous detection of microbial transglutaminase, and bovine and porcine fibrinogen/thrombin in restructured meat.

    Science.gov (United States)

    Jira, Wolfgang; Schwägele, Fredi

    2017-12-15

    A sensitive HPLC-MS/MS method for the simultaneous detection of microbial transglutaminase (TG) from Streptomyces mobaraensis, and bovine and porcine fibrinogen/thrombin in restructured meat was developed using tryptic marker peptides of TG (five markers), and bovine and porcine fibrinogen (six markers each). Meat binding experiments with beef and pork were performed using a technical TG mixture (Activa, Ajinomoto), and bovine and porcine plasmapowder FG (PPFG; Sonac B.V.). The method developed allows the simultaneous detection of the use of these cold-set binders in raw and heated samples. The peak areas of the fibrinogen marker peptides were increased by a factor of about 100, compared to blank values originating from the occurrence of residual blood in meat, using a concentration of 0.6% bovine and porcine PPFG. A differentiation between the use of blood plasma powder and PPFG using the ratios of fibrinogen to serotransferrin peptide peak areas seems to be possible. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Enhancing Plasma Surface Modification using high Intensity and high Power Ultrasonic Acoustic Waves

    DEFF Research Database (Denmark)

    2010-01-01

    high intensity and high power acoustic waves (102) by at least one ultrasonic high intensity and high power acoustic wave generator (101 ), wherein the ultrasonic acoustic waves are directed to propagate towards said surface (314) of the object (100) so that a laminar boundary layer (313) of a gas...... or a mixture of gases (500) flow in contact with said solid object (100) is thinned or destructed for at least a part of said surface (314). In this way, the plasma can more efficiently access and influence the surface of the solid object to be treated by the plasma, which speeds the process time up...

  6. High density high performance plasma with internal diffusion barrier in Large Helical Device

    International Nuclear Information System (INIS)

    Sakamoto, R.; Kobayashi, M.; Miyazawa, J.

    2008-10-01

    A attractive high density plasma operational regime, namely an internal diffusion barrier (IDB), has been discovered in the intrinsic helical divertor configuration on the Large Helical Device (LHD). The IDB which enables core plasma to access a high density/high pressure regime has been developed. It is revealed that the IDB is reproducibly formed by pellet fueling in the magnetic configurations shifted outward in major radius. Attainable central plasma density exceeds 1x10 21 m -3 . Central pressure reaches 1.5 times atmospheric pressure and the central β value becomes fairly high even at high magnetic field, i.e. β(0)=5.5% at B t =2.57 T. (author)

  7. High density turbulent plasma processes from a shock tube

    International Nuclear Information System (INIS)

    Oyedeji, O.; Johnson, J.A. III

    1991-01-01

    We have finished the first stages of our experimental and theoretical investigations on models for energy and momentum transport and for photon-particle collision processes in a turbulent quasi-stationary high density plasma. The system is explored by beginning to determine the turbulence phenomenology associated with an ionizing shock wave. The theoretical underpinnings are explored for phonon particle collisions by determining the collisional redistribution function, using Lioville Space Green's Function, which will characterize the inelastic scattering of the radiation from one frequency to another. We have observed that a weak magnetic field tends to increase the apparent random-like behaviors in a collisional turbulent plasma. On the theoretical side, we have been able to achieve a form for the collisional redistribution function. It remains to apply these concepts to a stationary turbulent plasma in the reflected ionizing shock wave and to exercise the implications of evaluations of the collisional redistribution function for such a system when it is probed by a strong radiation source. These results are discussed in detail in the publications, which have resulted from the this effort, cited at the end of the report

  8. High latitude plasma convection: Predictions for EISCAT and Sondre Stromfjord

    International Nuclear Information System (INIS)

    Sojka, J.J.; Raitt, W.J.; Schunk, R.W.

    1979-01-01

    We have used a plasma convection model to predict diurnal patterns of horizontal drift velocities in the vicinity of the EISCAT incoherent scatter facility at Tromso, Norway and for Sondre Stromfjord, Greenland, a proposed new incoherent scatter facility site. The convection model includes the offset of 11.4 0 between the geographic and geomagnetic poles (northern hemisphere), the tendency of plasma to corotate about the geographic pole, and a magnetospheric electric field mapped to a circle about a center offset by 5 0 in the antisunward direction from the magnetic pole. Four different magnetospheric electric field configurations were considered, including a constant cross-tail electric field, asymmetric electric fields with enhancements on the dawn and dusk sides of the polar cap, and an electric field pattern that is not aligned parallel to the noon-midnight magnetic meridian. The different electric field configurations produce different signatures in the plasma convection pattern which are clearly identified. Both of the high-latitude sites are better suited to study magnetospheric convection effects than either Chatanika, Alaska or Millstone Hill, Massachusetts. Also, each site appears to have unique capabilities with regard to studying certain aspects of the magnetospheric electric field

  9. Exploration of Plasma Jets Approach to High Energy Density Physics. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chiping [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2013-08-26

    High-energy-density laboratory plasma (HEDLP) physics is an emerging, important area of research in plasma physics, nuclear physics, astrophysics, and particle acceleration. While the HEDLP regime occurs at extreme conditions which are often found naturally in space but not on the earth, it may be accessible by colliding high intensity plasmas such as high-energy-density plasma jets, plasmoids or compact toroids from plasma guns. The physics of plasma jets is investigated in the context of high energy density laboratory plasma research. This report summarizes results of theoretical and computational investigation of a plasma jet undergoing adiabatic compression and adiabatic expansion. A root-mean-squared (rms) envelope theory of plasma jets is developed. Comparison between theory and experiment is made. Good agreement between theory and experiment is found.

  10. High density plasmas and new diagnostics: An overview (invited)

    International Nuclear Information System (INIS)

    Celona, L.; Gammino, S.; Mascali, D.

    2016-01-01

    One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including “volume-integrated” X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a “pin-hole camera” has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines

  11. Personal experience in the early diagnosis of deep venous thrombosis with the /sup 135/I-fibrinogen test

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, G P; Vicente, A B; Mestre, A P; Iglesias, R S; Irijoa, V; Garcia-Bengochea, J B

    1973-01-01

    The results in the early diagnosis of various surgical patients with a high rate of deep venous thrombosis, using the /sup 125/I Fibrinogen Test are presented. A 22 percent incidence of thrombosis was found, and certain limitations have been noticed which make the test only ideal for the venous system distal to the inguinal area and in legs without recent surgical wounds. The real value of the test, as the earliest method for detecting silent venous thrombosis of the legs is emphasized.

  12. Radial convection of finite ion temperature, high amplitude plasma blobs

    DEFF Research Database (Denmark)

    Wiesenberger, M.; Madsen, Jens; Kendl, Alexander

    2014-01-01

    We present results from simulations of seeded blob convection in the scrape-off-layer of magnetically confined fusion plasmas. We consistently incorporate high fluctuation amplitude levels and finite Larmor radius (FLR) effects using a fully nonlinear global gyrofluid model. This is in line......-field transport compared to blobs simulated with the local model. The maximal blob amplitude is significantly higher in the global simulations than in the local ones. When the ion temperature is comparable to the electron temperature, global blob simulations show a reduced blob coherence and a decreased cross...

  13. Bleeding Episodes Among Patients with Congenital Fibrinogen Disorders, a Study On 12 New Iranian Patients

    Directory of Open Access Journals (Sweden)

    Majid Naderi

    2018-01-01

    Full Text Available Background: Congenital fibrinogen disorders (CFDs comprise about 10% of rare bleeding disorders (RBDs. CFDs are divided into two groups of quantitative (afibrinogenemia and hypofibrinogenemia with autosomal recessive inheritance pattern, and qualitative (dysfibrinogenemia, hypodysfibrogenemia disorders, mainly with autosomal dominant inheritance pattern. Sistan and Baluchestan Province in Iran, with its high rate of consanguineous marriages, has a high incidence of RBDs including CFD. In the current study, we report clinical manifestations of patients with CFDs.Methods: Twelve new Iranian patients from Sistan and Baluchestan Province with different types of CFDs were selected for this study. Diagnosis of CFDs was based on clinical features and familial history followed by laboratory assessment by routine and specific coagulation tests including prothrombin time (PT and activated partial time tests (APTT, as well as FI activity assay by Clauss method.Results: Out of 12 patients, 3(25% had afibrinogenemia, 7(58.3% had hypofibrinogenemia while 2(16/7% were suspected of having dysfibrinogenemia. Although umbilical cord bleeding (UCB 9(75% was the most common clinical presentation among the study population, this feature was not observed among patients with dysfibrinogenemia. Hematoma (100% was the most common presentation of patients with dysfibrinogenemia.  Conclusion: Results of this study revealed that some clinical presentations are the diagnostic features of CFDs and can be used for precise and in-time diagnosis CFDs in conjunction with family history and laboratory findings.Keywords: Fibrinogen Deficiency; Congenital Afibrinogenemia; Blood Coagulation Disorder; Afibrinogenemia

  14. Forbidden lines of highly ionized ions for localized plasma diagnostics

    International Nuclear Information System (INIS)

    Hinnov, E.; Fonck, R.; Suckewer, S.

    1980-06-01

    Numerous optically forbidden lines resulting from magnetic dipole transitions in low-lying electron configurations of highly ionized Fe, Ti and Cr atoms have been identified in PLT and PDX tokamak discharges, and applied for localized diagnostics in the high-temperature (0.5 to 3.0 keV) interior of these plasmas. The measurements include determination of local ion densities and their variation in time, and of ion motions (ion temperature, plasma rotations) through Doppler effect of the lines. These forbidden lines are particularly appropriate for such measurements because under typical tokamak conditions their emissivities are quite high (10 11 to 10 14 photons/cm 3 -sec), and their relatively long wavelengths allow the use of intricate optical techniques and instrumentation. The spatial location of the emissivity is directly measurable, and tends to occur near radii where the ionization potential of the ion in question is equal to the local electron temperature. In future larger and presumably higher-temperature tokamaks analogous measurements with somewhat heavier atoms, particularly krypton, and perhaps zirconium appear both feasible and desirable

  15. High plasma uric acid concentration: causes and consequences

    Directory of Open Access Journals (Sweden)

    de Oliveira Erick

    2012-04-01

    Full Text Available Abstract High plasma uric acid (UA is a precipitating factor for gout and renal calculi as well as a strong risk factor for Metabolic Syndrome and cardiovascular disease. The main causes for higher plasma UA are either lower excretion, higher synthesis or both. Higher waist circumference and the BMI are associated with higher insulin resistance and leptin production, and both reduce uric acid excretion. The synthesis of fatty acids (tryglicerides in the liver is associated with the de novo synthesis of purine, accelerating UA production. The role played by diet on hyperuricemia has not yet been fully clarified, but high intake of fructose-rich industrialized food and high alcohol intake (particularly beer seem to influence uricemia. It is not known whether UA would be a causal factor or an antioxidant protective response. Most authors do not consider the UA as a risk factor, but presenting antioxidant function. UA contributes to > 50% of the antioxidant capacity of the blood. There is still no consensus if UA is a protective or a risk factor, however, it seems that acute elevation is a protective factor, whereas chronic elevation a risk for disease.

  16. Effect of fibrinogen on blood coagulation detected by optical coherence tomography

    International Nuclear Information System (INIS)

    Xu, Xiangqun; Teng, Xiangshuai

    2015-01-01

    Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d 1/e ) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d 1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0–8 g L −1 ); and 2) native plasma with commercial Fbg added (0–8 g L −1 ). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels. (paper)

  17. Interaction of energetic ions with high-density plasmas

    International Nuclear Information System (INIS)

    Gericke, D.O.; Edie, D.; Grinenko, A.; Vorberger, J.

    2010-01-01

    Complete text of publication follows. The talk will review the importance of energetic ions in different inertial confinement fusion scenarios: i) heavy ion beams are very efficient drivers that can deliver the energy for compression in indirect as well as direct drive approaches; ii) the interaction of α-particles, that are created in a burning plasma, with the surrounding cold plasma is essential for creating a burn wave; iii) laser-produced ion beams are also a strong candidate to create the hot spot needed for fast ignition. In all applications the ions interact with dense matter that is characterized by strongly coupled ions and (possibly) partially degenerate electrons. Moreover, the coupling between beam ions and target electrons can be strong as well. Under these conditions, standard approaches for the beam-plasma interactions process are known to fail. The presentation will demonstrate how advanced models for the energy loss of ions in dense plasmas can resolve the issues mentioned above. These models are largely built on quantum kinetic theory that is able to describe degeneracy and strong coupling in a systematic way. In particular, strong interactions require a quantum description for electron-ion collisions in dense plasma environments, which is done by direct solutions of the Schroedinger equation. Degeneracy and collective excitations can be included via the Lenard-Balescu description where strong interactions may be included via a pseudo-potential approach. Finally, results are shown for all three fusion applications described above. The effects related to strong coupling and degeneracy mainly concern the end of the stopping range where the beam ion dose not have enough energy to excite all possible degrees of freedom and, thus, certain processes are frozen out. However, we also find a significant reduction of the range for swift heavy ions in the GeV-range when stopping in dense matter is considered. The stopping range of α-particles in the

  18. Enhancing gas-phase reaction in a plasma using high intensity and high power ultrasonic acoustic waves

    DEFF Research Database (Denmark)

    2010-01-01

    is absorbed into said plasma (104), and where a sound pressure level of said generated ultrasonic high intensity and high power acoustic waves (102) is at least substantially 140 dB and where an acoustic power of said generated ultrasonic high intensity and high power acoustic waves (102); is at least...... substantially 100 W. In this way, a high sound intensity and power are obtained that efficiently enhances a gas-phase reaction in the plasma, which enhances the plasma process, e.g. enabling more efficient ozone or hydrogen generation using plasma in relation to reaction speed and/or obtained concentration......This invention relates to enhancing a gas-phase reaction in a plasma comprising: creating plasma (104) by at least one plasma source (106), and wherein that the method further comprises: generating ultrasonic high intensity and high power acoustic waves (102) having a predetermined amount...

  19. Sustained high βN plasmas on EAST tokamak

    Science.gov (United States)

    Gao, Xiang; the EAST team

    2018-05-01

    Sustained high normalized beta (βN ∼ 1.9) plasmas with an ITER-like tungsten divertor have been achieved on EAST tokamak recently. The high power NBI heating system of 4.8 MW and the 4.6 GHz lower hybrid wave of 1 MW were developed and applied to produce edge and internal transport barriers in high βN discharges. The central flat q profile with q (ρ) ∼ 1 at ρ safety factor q95 = 4.7 is identified by the multi-channel far-infrared laser polarimeter and the EFIT code. The fraction of non-inductive current is about 40%. The relation between fishbone activity and ITB formation is observed and discussed.

  20. High-Q plasmas in the TFTR tokamak

    International Nuclear Information System (INIS)

    Jassby, D.L.; Barnes, C.W.; Bell, M.G.; Bitter, M.; Boivin, R.; Bretz, N.L.; Budny, R.V.; Bush, C.E.; Dylla, H.F.; Efthimion, P.C.; Fredrickson, E.D.; Hawryluk, R.J.; Hill, K.W.; Hosea, J.; Hsuan, H.; Janos, A.C.; Jobes, F.C.; Johnson, D.W.; Johnson, L.C.; Kamperschroer, J.; Kieras-Phillips, C.; Kilpatrick, S.J.; LaMarche, P.H.; LeBlanc, B.; Mansfield, D.K.; Marmar, E.S.; McCune, D.C.; McGuire, K.M.; Meade, D.M.; Medley, S.S.; Mikkelsen, D.R.; Mueller, D.; Owens, D.K.; Park, H.K.; Paul, S.F.; Pitcher, S.; Ramsey, A.T.; Redi, M.H.; Sabbagh, S.A.; Scott, S.D.; Snipes, J.; Stevens, J.; Strachan, J.D.; Stratton, B.C.; Synakowski, E.J.; Taylor, G.; Terry, J.L.; Timberlake, J.R.; Towner, H.H.; Ulrickson, M.; von Goeler, S.; Wieland, R.M.; Williams, M.; Wilson, J.R.; Wong, K.; Young, K.M.; Zarnstorff, M.C.; Zweben, S.J.

    1991-01-01

    In the Tokamak Fusion Test Reactor (TFTR) [Plasma Phys. Controlled Fusion 26, 11 (1984)], the highest neutron source strength S n and D--D fusion power gain Q DD are realized in the neutral-beam-fueled and heated ''supershot'' regime that occurs after extensive wall conditioning to minimize recycling. For the best supershots, S n increases approximately as P 1.8 b . The highest-Q shots are characterized by high T e (up to 12 keV), T i (up to 34 keV), and stored energy (up to 4.7 MJ), highly peaked density profiles, broad T e profiles, and lower Z eff . Replacement of critical areas of the graphite limiter tiles with carbon-fiber composite tiles and improved alignment with the plasma have mitigated the ''carbon bloom.'' Wall conditioning by lithium pellet injection prior to the beam pulse reduces carbon influx and particle recycling. Empirically, Q DD increases with decreasing pre-injection carbon radiation, and increases strongly with density peakedness [n e (0)/left-angle n e right-angle] during the beam pulse. To date, the best fusion results are S n =5x10 16 n/sec, Q DD =1.85x10 -3 , and neutron yield=4.0x10 16 n/pulse, obtained at I p =1.6--1.9 MA and beam energy E b =95--103 keV, with nearly balanced co- and counter-injected beam power. Computer simulations of supershot plasmas show that typically 50%--60% of S n arises from beam--target reactions, with the remainder divided between beam--beam and thermonuclear reactions, the thermonuclear fraction increasing with P b

  1. High duty factor plasma generator for CERN's Superconducting Proton Linac.

    Science.gov (United States)

    Lettry, J; Kronberger, M; Scrivens, R; Chaudet, E; Faircloth, D; Favre, G; Geisser, J-M; Küchler, D; Mathot, S; Midttun, O; Paoluzzi, M; Schmitzer, C; Steyaert, D

    2010-02-01

    CERN's Linac4 is a 160 MeV linear accelerator currently under construction. It will inject negatively charged hydrogen ions into CERN's PS-Booster. Its ion source is a noncesiated rf driven H(-) volume source directly inspired from the one of DESY and is aimed to deliver pulses of 80 mA of H(-) during 0.4 ms at a 2 Hz repetition rate. The Superconducting Proton Linac (SPL) project is part of the luminosity upgrade of the Large Hadron Collider. It consists of an extension of Linac4 up to 5 GeV and is foreseen to deliver protons to a future 50 GeV synchrotron (PS2). For the SPL high power option (HP-SPL), the ion source would deliver pulses of 80 mA of H(-) during 1.2 ms and operate at a 50 Hz repetition rate. This significant upgrade motivates the design of the new water cooled plasma generator presented in this paper. Its engineering is based on the results of a finite element thermal study of the Linac4 H(-) plasma generator that identified critical components and thermal barriers. A cooling system is proposed which achieves the required heat dissipation and maintains the original functionality. Materials with higher thermal conductivity are selected and, wherever possible, thermal barriers resulting from low pressure contacts are removed by brazing metals on insulators. The AlN plasma chamber cooling circuit is inspired from the approach chosen for the cesiated high duty factor rf H(-) source operating at SNS.

  2. Localization of thrombi using the Ga-67-DFO-DAS fibrinogen

    International Nuclear Information System (INIS)

    Takahashi, Eriko; Ohta, Yoshiko; Kawasaki, Sachiko; Maki, Masako; Hiroe, Michiaki; Kusakabe, Kiyoko; Kohno, Atsushi; Shigeta, Akiko

    1985-01-01

    This report shows demonstrable thrombus imaging with Ga-67-DFO-DAS fibrinogen in a patient with Marfan's syndrome. Significant Ga-67-DFO-DAS fibrinogen deposition was noted in the leakage surrounding replased graft of ascending aorta and lesion of pulmonary parenchyma which was suspicious of pulmonary infarction. This results promises that Ga-67-DFO-DAS fibrinogen is a useful tool for evaluation of the clotting under various forms of therapy. (author)

  3. Fibrinogen depletion in trauma: early, easy to estimate and central to trauma-induced coagulopathy

    OpenAIRE

    Davenport, Ross; Brohi, Karim

    2013-01-01

    Fibrinogen is fundamental to hemostasis and falls rapidly in trauma hemorrhage, although levels are not routinely measured in the acute bleeding episode. Prompt identification of critically low levels of fibrinogen and early supplementation has the potential to correct trauma-induced coagulation and improve outcomes. Early estimation of hypofibrinogenemia is possible using surrogate markers of shock and hemorrhage; for example, hemoglobin and base excess. Rapid replacement with fibrinogen con...

  4. Fibrinogen depletion in trauma: early, easy to estimate and central to trauma-induced coagulopathy.

    Science.gov (United States)

    Davenport, Ross; Brohi, Karim

    2013-09-24

    Fibrinogen is fundamental to hemostasis and falls rapidly in trauma hemorrhage, although levels are not routinely measured in the acute bleeding episode. Prompt identification of critically low levels of fibrinogen and early supplementation has the potential to correct trauma-induced coagulation and improve outcomes. Early estimation of hypofibrinogenemia is possible using surrogate markers of shock and hemorrhage; for example, hemoglobin and base excess. Rapid replacement with fibrinogen concentrate or cryoprecipitate should be considered a clinical priority in major trauma hemorrhage.

  5. Changes in fibrinogen availability and utilization in an animal model of traumatic coagulopathy

    DEFF Research Database (Denmark)

    Hagemo, Jostein S; Jørgensen, Jørgen; Ostrowski, Sisse R

    2013-01-01

    Impaired haemostasis following shock and tissue trauma is frequently detected in the trauma setting. These changes occur early, and are associated with increased mortality. The mechanism behind trauma-induced coagulopathy (TIC) is not clear. Several studies highlight the crucial role of fibrinogen...... in posttraumatic haemorrhage. This study explores the coagulation changes in a swine model of early TIC, with emphasis on fibrinogen levels and utilization of fibrinogen....

  6. High density plasma gun generates plasmas at 190 kilometers per second

    Science.gov (United States)

    Espy, P. N.

    1971-01-01

    Gun has thin metal foil disc which positions or localizes gas to be ionized during electrical discharge cycle, overcoming major limiting factor in obtaining such plasmas. Expanding plasma front travels at 190 km/sec, compared to plasmas of 50 to 60 km/sec previously achieved.

  7. [A comparative and technical assessment of the HELP system (heparin extracorporeal LDL precipitation) and cascade filtration (CF) for the treatment of high plasma lipids].

    Science.gov (United States)

    Loschiavo, Carmelo

    2013-01-01

    Extracorporeal techniques for the removal of plasma lipids, known as LDL-apheresis, have improved treatment of atherosclerotic lesions in patients with familial hyperlipidemia (FH). In the homozygous form, such treatment is to be considered a life-saving therapy, and in heterozygous forms, which are widely distributed in the population, it is also used when there is a high risk of coronary atherogenic lesions and where a dietary and pharmacological approach has failed to satisfy the objective of a LDL-C 2.6 mmol/L. Of the various techniques available, we believe that cascade filtration (CF) and extracorporeal LDL precipitation with heparin (HELP) are the methods of choice for technical reasons, clinical efficacy and safety. HELP provides, at long-term follow-up, a 5% greater decrease in LDL-C and Lp (a) compared to CF, and about 10% increase in fibrinogen removal resulting in decreased blood viscosity. Conversely, CF produces a concomitant elimination of up to 20% of HDL-C, whereas HELP results in around 5% elimination. CF determines a loss of protein which over time can impact negatively on the protein profile, while HELP results in negligible protein loss. Finally, a significant dampening effect on the intermediate products of inflammation, which initiate the process of vessel atheroma development, has been documented only with HELP. Therefore, the HELP procedure appears to inhibit the development of atheromatous plaques via several different routes.

  8. Thermal history of the plasma and high-frequency gravitons

    CERN Document Server

    Giovannini, Massimo

    2009-01-01

    Possible deviations from a radiation-dominated evolution, occurring prior the synthesis of light nuclei, impacted on the spectral energy density of high-frequency gravitons. For a systematic scrutiny of this situation, the $\\Lambda$CDM paradigm must be complemented by (at least two) physical parameters describing, respectively, a threshold frequency and a slope. The supplementary frequency scale sets the lower border of a high-frequency domain where the spectral energy grows with a slope which depends, predominantly, upon the total sound speed of the plasma right after inflation. While the infra-red region of the graviton energy spectrum is nearly scale-invariant, the expected signals for typical frequencies larger than 0.01 nHz are hereby analyzed in a model-independent framework by requiring that the total sound speed of the post-inflationary plasma is smaller than the speed of light. Current (e.g. low-frequency) upper limits on the tensor power spectra (determined from the combined analysis of the three la...

  9. Cross-linking methods of electrospun fibrinogen scaffolds for tissue engineering applications

    International Nuclear Information System (INIS)

    Sell, Scott A; Garg, Koyal; McClure, Michael J; Bowlin, Gary L; Francis, Michael P; Simpson, David G

    2008-01-01

    The purpose of this study was to enhance the mechanical properties and slow the degradation of an electrospun fibrinogen scaffold, while maintaining the scaffold's high level of bioactivity. Three different cross-linkers were used to achieve this goal: glutaraldehyde vapour, 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) in ethanol and genipin in ethanol. Scaffolds with a fibrinogen concentration of 120 mg ml -1 were electrospun and cross-linked with one of the aforementioned cross-linkers. Mechanical properties were determined through uniaxial tensile testing performed on scaffolds incubated under standard culture conditions for 1 day, 7 days and 14 days. Cross-linked scaffolds were seeded with human foreskin fibroblasts (BJ-GFP-hTERT) and cultured for 7, 14 and 21 days, with histology and scanning electron microscopy performed upon completion of the time course. Mechanical testing revealed significantly increased peak stress and modulus values for the EDC and genipin cross-linked scaffolds, with significantly slowed degradation. However, cross-linking with EDC and genipin was shown to have some negative effect on the bioactivity of the scaffolds as cell migration throughout the thickness of the scaffold was slowed.

  10. Fibrinogen Demonstration in Oral Lichen Planus: An Immunofluorescence Study on Archival Tissues.

    Science.gov (United States)

    Shirol, Pallavi D; Naik, Veena; Kale, Alka

    2015-10-01

    Lichen planus is a premalignant condition with minimal diagnostic aids. This study is an attempt to use paraffin embedded sections of lichen planus with immunofluorescein stain and to evaluate the immunofluorescent sections to establish pattern of fibrinogen deposition. Thirty-five paraffin embedded sections of old and new cases of oral lichen planus (study group) and five normal oral mucosa (control group) were chosen. Two sections of each (H & E) case were taken, one was stained with hematoxylin and eosin and another with fluorescein isothiocynate conjugate (FITC) polyclonal rabbit antibody against fibrinogen. Fluorescent findings were examined with a fluorescent microscope. A high statistical significant correlation was found in respect to fluorescence positivity, intensity of fluorescence and distribution of fluorescence each with p < 0.0001 and fluorescence at blood vessel walls (p = 0.0003). This study suggested that paraffin embedded sections can be successfully used in direct immunofluorescence staining in routine set up where only formalin fixed tissues are received. Paraffin embedded sections can be successfully used in direct immunofluorescence staining when only formalin fixed tissues are received.

  11. Physics of high performance JET plasmas in D-T

    International Nuclear Information System (INIS)

    2001-01-01

    JET has recently operated with deuterium-tritium (D-T) mixtures, carried out an ITER physics campaign in hydrogen, deuterium, D-T and tritium, installed the Mark IIGB ''Gas Box'' divertor fully by remote handling and started physics experiments with this more closed divertor. The D-T experiments set records for fusion power (16.1 MW), ratio of fusion power to plasma input power (0.62, and 0.95±0.17 if a similar plasma could be obtained in steady-state) and fusion duration (4 MW for 4 s). A large scale tritium supply and processing plant, the first of its kind, allowed the repeated use of the 20 g tritium on site to supply 99.3 g of tritium to the machine. The H-mode threshold power is significantly lower in D-T, but the global energy confinement time is practically unchanged (no isotope effect). Dimensionless scaling ''Wind Tunnel'' experiments in D-T extrapolate to ignition with ITER parameters. The scaling is close to gyroBohm, but the mass dependence is not correct. Separating the thermal plasma energy into core and pedestal contributions could resolve this discrepancy (leading to proper gyroBohm scaling for the core) and also account for confinement degradation at high density and at high radiated power. Four radio frequency heating schemes have been tested successfully in D-T, showing good agreement with calculations. Alpha particle heating has been clearly observed and is consistent with classical expectations. Internal transport barriers have been established in optimised magnetic shear discharges for the first time in D-T and steady-state conditions have been approached with simultaneous internal and edge transport barriers. First results with the newly installed Mark IIGB divertor show that the in/out symmetry of the divertor plasma can be modified using differential gas fuelling, that optimised shear discharges can be produced, and that krypton gas puffing is effective in restoring L-mode edge conditions and establishing an internal transport barrier in

  12. Physics of high performance jet plasmas in D-T

    International Nuclear Information System (INIS)

    1999-01-01

    JET has recently operated with deuterium-tritium (D-T) mixtures, carried out an ITER physics campaign in hydrogen, deuterium, D-T and tritium, installed the Mark IIGB 'Gas Box' divertor fully by remote handling and started physics experiments with this more closed divertor. The D-T experiments set records for fusion power (16.1 MW), ratio of fusion power to plasma input power (0.62, and 0.95±0.17 if a similar plasma could be obtained in steady-state) and fusion duration (4 MW for 4 s). A large scale tritium supply and processing plant, the first of its kind, allowed the repeated use of the 20 g tritium on site to supply 99.3 g of tritium to the machine. The H-mode threshold power is significantly lower in D-T, but the global energy confinement time is practically unchanged (no isotope effect). Dimensionless scaling 'Wind Tunnel' experiments in D-T extrapolate to ignition with ITER parameters. The scaling is close to gyroBohm, but the mass dependence is not correct. Separating the thermal plasma energy into core and pedestal contributions could resolve this discrepancy (leading to proper gyroBohm scaling for the core) and also account for confinement degradation at high density and at high radiated power. Four radio frequency heating schemes have been tested successfully in D-T, showing good agreement with calculations. Alpha particle heating has been clearly observed and is consistent with classical expectations. Internal transport barriers have been established in optimised magnetic shear discharges for the first time in D-T and steady-state conditions have been approached with simultaneous internal and edge transport barriers. First results with the newly installed Mark IIGB divertor show that the in/out symmetry of the divertor plasma can be modified using differential gas fuelling, that optimised shear discharges can be produced, and that krypton gas puffing is effective in restoring L-mode edge conditions and establishing an internal transport barrier in such

  13. Physics of integrated high-performance NSTX plasmas

    International Nuclear Information System (INIS)

    Menard, J. E.; Bell, M. G.; Bell, R. E.; Fredrickson, E. D.; Gates, D. A.; Heidbrink, W.; Kaita, R.; Kaye, S. M.; Kessel, C. E.; Kugel, H.; LeBlanc, B. P.; Lee, K. C.; Levinton, F. M.; Maingi, R.; Medley, S. S.; Mikkelsen, D. R.; Mueller, D.; Nishino, N.; Ono, M.; Park, H.; Park, W.; Paul, S. F.; Peebles, T.; Peng, M.; Raman, R.; Redi, M.; Roquemore, L.; Sabbagh, S. A.; Skiner, C. H.; Sontag, A.; Soukhanovskii, V.; Stratton, B.; Stutman, D.; Synakowski, E.; Takase, Y.; Taylor, G.; Tritz, K.; Wade, M.; Wilson, J. R.; Zhu, W.

    2005-01-01

    An overarching goal of magnetic fusion research is the integration of steady state operation with high fusion power density, high plasma β, good thermal and fast particle confinement, and manageable heat and particle fluxes to reactor internal components. NSTX has made significant progress in integrating and understanding the interplay between these competing elements. Sustained high elongation up to 2.5 and H-mode transitions during the I p ramp-up have increased β p and reduced l i at high current resulting in I p flat-top durations exceeding 0.8s for I p >0.8MA. These shape and profile changes delay the onset of deleterious global MHD activity yielding β N values >4.5 and β T ∼20% maintained for several current diffusion times. Higher ∫ N discharges operating above the non-wall limit are sustained via rotational stabilization of the RWM. H-mode confinement scaling factors relative to H98(y,2) span the range 1±0.4 for B T >4kG and show a stron (Nearly linear) residual scaling with B T . Power balance analysis indicates the electron thermal transport dominates the loss power in beam-heated H m ode discharges, but the core χ e can be significantly reduced through current profile modification consistent with reversed magnetic shear. Small ELM regimes have been obtained in high performance plasmas on NSTX, but the ELM type and associated pedestal energy loss are found to depend sensitively on the boundary elongation, magnetic balance, and edge collisionality. NPA data and TRANSP analysis suggest resonant interactions with mid-radius tearing modes may lead to large fast-ion transport. The associated fast-ion diffusion and/or loss likely impact(s) both the driven current and power deposition profiles from NBI heating. Results from experiments to initiate the plasma without the ohmic solenoid and integrated scenario with the TSC code will also be described. (Author)

  14. Kinetics of Iodine 131 labelled fibrinogen in cancerous patients. Pharmacological study

    International Nuclear Information System (INIS)

    Boneu-Valmalette, Andree; Bugat, Roland; David, J.-F.; Combes, P.-F.

    1977-01-01

    The results obtained in a previous study using 131 I fibrinogen in cancerous patients suggested a local intravascular clotting process. In order to elucidate the mechanism of fibrinogen kinetic abnormalities different drugs including heparin, prednisone, ticlopidin, aspirin and indomethacin were administred in 68 patients and their effects evaluated by change in the 131 I fibrinogen disappearance rate. The results suggest that these drugs may counteract with the early stages of coagulation (kinin-forming system, factor XII) and that abnormal 131 I fibrinogen kinetic in cancer would be a non specific phenomenon [fr

  15. Ulysses solar wind plasma observations at high southerly latitudes.

    Science.gov (United States)

    Phillips, J L; Bame, S J; Feldman, W C; Gosling, J T; Hammond, C M; McComas, D J; Goldstein, B E; Neugebauer, M; Scime, E E; Suess, S T

    1995-05-19

    Solar wind plasma observations made by the Ulysses spacecraft through -80.2 degrees solar latitude and continuing equatorward to -40.1 degrees are summarized. Recurrent high-speed streams and corotating interaction regions dominated at middle latitudes. The speed of the solar wind was typically 700 to 800 kilometers per second poleward of -35 degrees . Corotating reverse shocks persisted farther south than did forward shocks because of the tilt of the heliomagnetic streamer belt. Sporadic coronal mass ejections were seen as far south as -60.5 degrees . Proton temperature was higher and the electron strahl was broader at higher latitudes. The high-latitude wind contained compressional, pressure-balanced, and Alfvénic structures.

  16. High-order harmonic generation in laser plasma plumes

    CERN Document Server

    Ganeev, Rashid A

    2013-01-01

    This book represents the first comprehensive treatment of high-order harmonic generation in laser-produced plumes, covering the principles, past and present experimental status and important applications. It shows how this method of frequency conversion of laser radiation towards the extreme ultraviolet range matured over the course of multiple studies and demonstrated new approaches in the generation of strong coherent short-wavelength radiation for various applications. Significant discoveries and pioneering contributions of researchers in this field carried out in various laser scientific centers worldwide are included in this first attempt to describe the important findings in this area of nonlinear spectroscopy. "High-Order Harmonic Generation in Laser Plasma Plumes" is a self-contained and unified review of the most recent achievements in the field, such as the application of clusters (fullerenes, nanoparticles, nanotubes) for efficient harmonic generation of ultrashort laser pulses in cluster-containin...

  17. High plasma homocyst(e)ine levels in elderly Japanese patients are associated with increased cardiovascular disease risk independently from markers of coagulation activation and endothelial cell damage.

    Science.gov (United States)

    Kario, K; Duell, P B; Matsuo, T; Sakata, T; Kato, H; Shimada, K; Miyata, T

    2001-08-01

    Elevated plasma homocyst(e)ine is a risk factor for cardiovascular disease (CVD) in many populations, but the relationship between homocyst(e)ine and CVD in Japanese subjects has been unclear. It has been hypothesized that the link between homocyst(e)ine and CVD may be mediated in part by activation of coagulation and endothelial cell injury in the elderly Japanese subjects. To further evaluate this hypothesis, the present cross-sectional study was designed to assess the relationships among plasma homocyst(e)ine concentrations, risk of CVD, and markers of coagulation (fibrinogen, FVII, F1+2, FVIIa and FXIIa) and endothelial cell damage (vWF and thrombomodulin) in 146 elderly Japanese subjects (79 healthy controls and 67 patients with CVD). The geometric mean (range) of plasma homocyst(e)ine concentrations was 10.2 (3.2--33) micromol/l in 79 Japanese healthy elderly subjects. As expected, healthy female and male elderly subjects had homocyst(e)ine levels that were 2.5 and 5.3 micromol/; higher, respectively, compared to healthy young control subjects (n=62). Healthy young and elderly men had homocyst(e)ine levels that were 1.7 and 4.5 micromol/l higher, respectively, compared to values in women. This higher plasma homocyst(e)ine levels in the elderly subjects were negatively correlated with levels of folic acid, albumin and total cholesterol, but were not significantly related to markers of coagulation or endothelial cell-damage. The results of multiple logistic regression analyses suggested that high homocyst(e)ine levels were independently related to CVD risk. In addition, levels of FVIIa, and F1+2 were significantly higher in elderly Japanese patients with CVD compared to elderly subjects without CVD, but were unrelated to plasma homocyst(e)ine concentrations. In summary, elevated plasma concentrations of homocyst(e)ine, FVIIa, and F1+2 were associated with increased risk of CVD in elderly male and female Japanese subjects, but the association between homocyst

  18. Vortices, Reconnection and Turbulence in High Electron-Beta Plasmas

    International Nuclear Information System (INIS)

    Stenzel, R. L.

    2004-01-01

    Plasmas in which the kinetic energy exceeds the magnetic energy by a significant factor are common in space and in the laboratory. Such plasmas can convect magnetic fields and create null points in whose vicinity first the ions become unmagnetized, then the electrons. This project focuses on the detailed study of the transition regime of these plasmas

  19. Study of the fibrinogen - fibrin transformation kinetics and modifications caused to this reaction by irradiation (X rays) of the fibrinogen solution

    International Nuclear Information System (INIS)

    Hollard, D.; Suscillon, M.; Marcille, G.; Rambaud, F.; Baloyan, M.

    1966-01-01

    The authors present a spectrophotometric method for studying the transformation fibrinogen - fibrin. This method has the advantage of drawing immediately in graph form the three, phases of this transformation: proteolysis or monomerization; polymerisation; clot stabilization. It is a simple, faithful and easily reproductive technic. Owing to this method, they studied modifications of this transformation due to irradiation of fibrinogen solution. Low doses (90 000 R/mn) prevent transverse polymerisation. To upper doses (180 000 R and more), the action of thrombin on fibrinogen does not give an organised clot but a lacteous and fragile gel. There is not here a coagulation in the physiological understanding. (author) [fr

  20. A high-current pulsed cathodic vacuum arc plasma source

    International Nuclear Information System (INIS)

    Oates, T.W.H.; Pigott, J.; Mckenzie, D.R.; Bilek, M.M.M.

    2003-01-01

    Cathodic vacuum arcs (CVAs) are well established as a method for producing metal plasmas for thin film deposition and as a source of metal ions. Fundamental differences exist between direct current (dc) and pulsed CVAs. We present here results of our investigations into the design and construction of a high-current center-triggered pulsed CVA. Power supply design based on electrolytic capacitors is discussed and optimized based on obtaining the most effective utilization of the cathode material. Anode configuration is also discussed with respect to the optimization of the electron collection capability. Type I and II cathode spots are observed and discussed with respect to cathode surface contamination. An unfiltered deposition rate of 1.7 nm per pulse, at a distance of 100 mm from the source, has been demonstrated. Instantaneous plasma densities in excess of 1x10 19 m -3 are observed after magnetic filtering. Time averaged densities an order of magnitude greater than common dc arc densities have been demonstrated, limited by pulse repetition rate and filter efficiency

  1. Thin films growth parameters in MAPLE; application to fibrinogen

    International Nuclear Information System (INIS)

    Jelinek, M; Cristescu, R; Kocourek, T; Vorlicek, V; Remsa, J; Stamatin, L; Mihaiescu, D; Stamatin, I; Mihailescu, I N; Chrisey, D B

    2007-01-01

    Increasingly requirements on the thin film quality of functionalized materials are efficiently met by a novel laser processing technique - Matrix Assisted Pulsed Laser Evaporation (MAPLE). Examples of deposition conditions and main features characteristic to film growth rate of MAPLE-fabricated organic materials are summarized. MAPLE experimental results are compared with ones corresponding to the classical Pulsed Laser Deposition (PLD). In particular, the results of investigation of MAPLE-deposited fibrinogen blood protein thin films using a KrF* excimer laser and characterized by FTIR and Raman spectrometry are reported

  2. High-Intensity High-order Harmonics Generated from Low-Density Plasma

    International Nuclear Information System (INIS)

    Ozaki, T.; Bom, L. B. Elouga; Abdul-Hadi, J.; Ganeev, R. A.; Haessler, S.; Salieres, P.

    2009-01-01

    We study the generation of high-order harmonics from lowly ionized plasma, using the 10 TW, 10 Hz laser of the Advanced Laser Light Source (ALLS). We perform detailed studies on the enhancement of a single order of the high-order harmonic spectrum generated in plasma using the fundamental and second harmonic of the ALLS beam line. We observe quasi-monochromatic harmonics for various targets, including Mn, Cr, Sn, and In. We identify most of the ionic/neutral transitions responsible for the enhancement, which all have strong oscillator strengths. We demonstrate intensity enhancements of the 13th, 17th, 29th, and 33rd harmonics from these targets using the 800 nm pump laser and varying its chirp. We also characterized the attosecond nature of such plasma harmonics, measuring attosecond pulse trains with 360 as duration for chromium plasma, using the technique of ''Reconstruction of Attosecond Beating by Interference of Two-photon Transitions''(RABBIT). These results show that plasma harmonics are intense source of ultrashort coherent soft x-rays.

  3. Role of impurities in magnetically confined high temperature plasmas

    International Nuclear Information System (INIS)

    Barnett, C.F.

    1976-01-01

    A summary is given of the atomic physics concerned with plasma cooling by impurities and the limiting effect that impurities may have on heating of plasmas by neutral injection. A general description is given of the tokamak concept and the present and next generation experiments are described. The time and spatial behavior of O and Mo multicharged ions in present hydrogen plasmas is presented. This is followed by a discussion of the power loss from a plasma containing one percent Fe. Finally, the limitation of plasma heating by energetic H or D injection is summarized

  4. Cancer therapy using non-thermal atmospheric pressure plasma with ultra-high electron density

    International Nuclear Information System (INIS)

    Tanaka, Hiromasa; Mizuno, Masaaki; Toyokuni, Shinya; Maruyama, Shoichi; Kodera, Yasuhiro; Terasaki, Hiroko; Adachi, Tetsuo; Kato, Masashi; Kikkawa, Fumitaka; Hori, Masaru

    2015-01-01

    Cancer therapy using non-thermal atmospheric pressure plasma is a big challenge in plasma medicine. Reactive species generated from plasma are key factors for treating cancer cells, and thus, non-thermal atmospheric pressure plasma with high electron density has been developed and applied for cancer treatment. Various cancer cell lines have been treated with plasma, and non-thermal atmospheric plasma clearly has anti-tumor effects. Recent innovative studies suggest that plasma can both directly and indirectly affect cells and tissues, and this observation has widened the range of applications. Thus, cancer therapy using non-thermal atmospheric pressure plasma is promising. Animal experiments and understanding the mode of action are essential for clinical application in the future. A new academic field that combines plasma science, the biology of free radicals, and systems biology will be established

  5. Cancer therapy using non-thermal atmospheric pressure plasma with ultra-high electron density

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hiromasa [Institute of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Center for Advanced Medicine and Clinical Research, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Mizuno, Masaaki [Center for Advanced Medicine and Clinical Research, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Toyokuni, Shinya [Department of Pathology and Biological Responses, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Maruyama, Shoichi [Department of Nephrology, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Kodera, Yasuhiro [Department of Gastroenterological Surgery (Surgery II), Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Terasaki, Hiroko [Department of Ophthalmology, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Adachi, Tetsuo [Laboratory of Clinical Pharmaceutics, Gifu Pharmaceutical University, 501-1196 Gifu (Japan); Kato, Masashi [Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Kikkawa, Fumitaka [Department of Obstetrics and Gynecology, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Hori, Masaru [Institute of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2015-12-15

    Cancer therapy using non-thermal atmospheric pressure plasma is a big challenge in plasma medicine. Reactive species generated from plasma are key factors for treating cancer cells, and thus, non-thermal atmospheric pressure plasma with high electron density has been developed and applied for cancer treatment. Various cancer cell lines have been treated with plasma, and non-thermal atmospheric plasma clearly has anti-tumor effects. Recent innovative studies suggest that plasma can both directly and indirectly affect cells and tissues, and this observation has widened the range of applications. Thus, cancer therapy using non-thermal atmospheric pressure plasma is promising. Animal experiments and understanding the mode of action are essential for clinical application in the future. A new academic field that combines plasma science, the biology of free radicals, and systems biology will be established.

  6. On the atomic line profiles in high pressure plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, J. F. J.; Gnybida, M.; Rijke, A. J.; Dijk, J. van [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Suijker, J. L. G. [Philips Lighting R and D Category Professional Lamps, P.O. Box 80020, 5600 JM Eindhoven (Netherlands)

    2013-11-14

    In a previous contribution to this journal [H. P. Stormberg, J. Appl. Phys. 51(4), 1963 (1980)], Stormberg presented an analytical expression for the convolution of Lorentz and Levy line profiles, which models atomic radiative transitions in high pressure plasmas. Unfortunately, the derivations are flawed with errors and the final expression, while correct, is accompanied by misguiding comments about the meaning of the symbols used therein, in particular the “complex error function.” In this paper, we discuss the broadening mechanisms that give rise to Stormberg's model and present a correct derivation of his final result. We will also provide an alternative expression, based on the Faddeeva function, which has decisive computational advantages and emphasizes the real-valuedness of the result. The MATLAB/Octave scripts of our implementation have been made available on the publisher's website for future reference.

  7. Properties of partially ionized hydrogen plasmas in high electric fields

    International Nuclear Information System (INIS)

    Morawetz, K.

    1993-03-01

    In this thesis the fundamental equations of many-particle quantum-statistics of nonequilibrium are treated in respect to arbitrary high electric fields. Generalizations are found for the T-matrix approximation as well as for the shielded potential approximation valid for any field strength. These result in a non-Markovian behavior of the obtained collision integrals, also known as intra-collisional-field-effect (ICFE), and in a broadening of the energy conservation, the so-called collisional broadening (CB), caused by applied electric fields. In linear response it is shown in a new way, how the Debye-Onsager relaxation effect can be rederived from these collision integrals. Furthermore the complete quantum result is presented. Both effects, ICFE and CB, contribute to the right classical limit. The quantum result yields an surprising maximum of this field effects in dependence of the interacting mass ratio, which may be important in exciton-plasmas and semiconductors. (orig.)

  8. CENTER FOR PULSED POWER DRIVEN HIGH ENERGY DENSITY PLASMA STUDIES

    Energy Technology Data Exchange (ETDEWEB)

    Professor Bruce R. Kusse; Professor David A. Hammer

    2007-04-18

    This annual report summarizes the activities of the Cornell Center for Pulsed-Power-Driven High-Energy-Density Plasma Studies, for the 12-month period October 1, 2005-September 30, 2006. This period corresponds to the first year of the two-year extension (awarded in October, 2005) to the original 3-year NNSA/DOE Cooperative Agreement with Cornell, DE-FC03-02NA00057. As such, the period covered in this report also corresponds to the fourth year of the (now) 5-year term of the Cooperative Agreement. The participants, in addition to Cornell University, include Imperial College, London (IC), the University of Nevada, Reno (UNR), the University of Rochester (UR), the Weizmann Institute of Science (WSI), and the P.N. Lebedev Physical Institute (LPI), Moscow. A listing of all faculty, technical staff and students, both graduate and undergraduate, who participated in Center research activities during the year in question is given in Appendix A.

  9. High power light gas helicon plasma source for VASIMR

    International Nuclear Information System (INIS)

    Squire, Jared P.; Chang-Diaz, Franklin R.; Glover, Timothy W.; Jacobson, Verlin T.; McCaskill, Greg E.; Winter, D. Scott; Baity, F. Wally; Carter, Mark D.; Goulding, Richard H.

    2006-01-01

    In the Advanced Space Propulsion Laboratory (ASPL) helicon experiment (VX-10) we have measured a plasma flux to input gas rate ratio near 100% for both helium and deuterium at power levels up to 10 kW. Recent results at Oak Ridge National Laboratory (ORNL) show enhanced efficiency operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 10 kW of input power. The data here uses a Boswell double-saddle antenna design with a magnetic cusp just upstream of the antenna. Similar to ORNL, for deuterium at near 10 kW, we find an enhanced performance of operation at magnetic fields above the lower hybrid matching condition

  10. Plasma conditions for non-Maxwellian electron distributions in high current discharges and laser-produced plasmas

    International Nuclear Information System (INIS)

    Whitney, K.G.; Pulsifer, P.E.

    1993-01-01

    Results from the standard quasilinear theory of ion-acoustic and Langmuir plasma microturbulence are incorporated into the kinetic theory of the electron distribution function. The theory is then applied to high current discharges and laser-produced plasmas, where either the current flow or the nonlinear laser-light absorption acts, respectively, as the energy source for the microturbulence. More specifically, the theory is applied to a selenium plasma, whose charge state is determined under conditions of collisional-radiative equilibrium, and plasma conditions are found under which microturbulence strongly influences the electron kinetics. In selenium, we show that this influence extends over a wide range of plasma conditions. For ion-acoustic turbulence, a criterion is derived, analogous to one previously obtained for laser heated plasmas, that predicts when Ohmic heating dominates over electron-electron collisions. This dominance leads to the generation of electron distributions with reduced high-energy tails relative to a Maxwellian distribution of the same temperature. Ion-acoustic turbulence lowers the current requirements needed to generate these distributions. When the laser heating criterion is rederived with ion-acoustic turbulence included in the theory, a similar reduction in the laser intensity needed to produce non-Maxwellian distributions is found. Thus we show that ion-acoustic turbulence uniformly (i.e., by the same numerical factor) reduces the electrical and heat conductivities, as well as the current (squared) and laser intensity levels needed to drive the plasma into non-Maxwellian states

  11. Targeted deletion of fibrinogen like protein 1 reveals a novel role in energy substrate utilization.

    Directory of Open Access Journals (Sweden)

    Valeriy Demchev

    Full Text Available Fibrinogen like protein 1(Fgl1 is a secreted protein with mitogenic activity on primary hepatocytes. Fgl1 is expressed in the liver and its expression is enhanced following acute liver injury. In animals with acute liver failure, administration of recombinant Fgl1 results in decreased mortality supporting the notion that Fgl1 stimulates hepatocyte proliferation and/or protects hepatocytes from injury. However, because Fgl1 is secreted and detected in the plasma, it is possible that the role of Fgl1 extends far beyond its effect on hepatocytes. In this study, we show that Fgl1 is additionally expressed in brown adipose tissue. We find that signals elaborated following liver injury also enhance the expression of Fgl1 in brown adipose tissue suggesting that there is a cross talk between the injured liver and adipose tissues. To identify extra hepatic effects, we generated Fgl1 deficient mice. These mice exhibit a phenotype suggestive of a global metabolic defect: Fgl1 null mice are heavier than wild type mates, have abnormal plasma lipid profiles, fasting hyperglycemia with enhanced gluconeogenesis and exhibit differences in white and brown adipose tissue morphology when compared to wild types. Because Fgl1 shares structural similarity to Angiopoietin like factors 2, 3, 4 and 6 which regulate lipid metabolism and energy utilization, we postulate that Fgl1 is a member of an emerging group of proteins with key roles in metabolism and liver regeneration.

  12. Dispersion relation and Landau damping of waves in high-energy density plasmas

    International Nuclear Information System (INIS)

    Zhu Jun; Ji Peiyong

    2012-01-01

    We present a theoretical investigation on the propagation of electromagnetic waves and electron plasma waves in high energy density plasmas using the covariant Wigner function approach. Based on the covariant Wigner function and Dirac equation, a relativistic quantum kinetic model is established to describe the physical processes in high-energy density plasmas. With the zero-temperature Fermi–Dirac distribution, the dispersion relation and Landau damping of waves containing the relativistic quantum corrected terms are derived. The relativistic quantum corrections to the dispersion relation and Landau damping are analyzed by comparing our results with those obtained in classical and non-relativistic quantum plasmas. We provide a detailed discussion on the Landau damping obtained in classical plasmas, non-relativistic Fermi plasmas and relativistic Fermi plasmas. The contributions of the Bohm potential, the Fermi statistics pressure and relativistic effects to the dispersion relation and Landau damping of waves are quantitatively calculated with real plasma parameters. (paper)

  13. Residual gas entering high density hydrogen plasma: rarefaction due to rapid heating

    NARCIS (Netherlands)

    N. den Harder,; D.C. Schram,; W. J. Goedheer,; de Blank, H. J.; M. C. M. van de Sanden,; van Rooij, G. J.

    2015-01-01

    The interaction of background molecular hydrogen with magnetized (0.4 T) high density (1–5 × 10 20  m −3 ) low temperature (∼3 eV) hydrogen plasma was inferred from the Fulcher band emission in the linear plasma generator Pilot-PSI. In the plasma center,

  14. Thermographic determination of the sheath heat transmission coefficient in a high density plasma

    NARCIS (Netherlands)

    Berg, van den M.A.; Bystrov, K.E.; Pasquet, R.; Zielinski, J.J.; De Temmerman, G.C.

    2013-01-01

    Experiments were performed in the Pilot-PSI linear plasma device, to determine the sheath heat transmission coefficients in a high recycling regime under various conditions of density (1–20 × 1020 m-3) and plasma composition (H2, Ar, N2) relevant for the ITER divertor plasma. The 2D surface

  15. The role of high speed photography in plasma instability research on the AEC tokamak

    International Nuclear Information System (INIS)

    Fletcher, J.D.; Coster, D.P.; De Villiers, J.A.M.; Kotze, P.B.; Nothnagel, G.; O'Mahony, J.R.; Roberts, D.E.; Sherwell, D.

    1986-01-01

    High speed cine photography is a useful diagnostic aid for studying plasma behaviour and plasma surface interactions in fusion research devices like tokamaks. Such a system has been installed on the AEC tokamak. This paper reports some preliminary results obtained during typical plasma discharges

  16. Bremsstrahlung spectra for Al, Cs, and Au atoms in high-temperature, high-density plasmas

    International Nuclear Information System (INIS)

    Kim, L.; Pratt, R.H.; Tseng, H.K.

    1985-01-01

    Results are presented from a numerical calculation for the bremsstrahlung spectrum and Gaunt factors of Al, Cs, and Au atoms in high-temperature (-T), high-density (-rho) plasmas. Plasma temperatures kT = 0.1 and 1.0 keV and plasma densities rho = rho 0 (the normal solid density) and rho = 100rho 0 are considered. This allows us to determine the generality and identify the origins of features which we had previously identified in calculations for Cs. We also now present results for the total energy loss of an electron in such a plasma. We use a relativistic multipole code which treats the bremsstrahlung process as a single-electron transition in a static screened central potential. We take for the static potential corresponding to an atom in a hot dense plasma the finite-temperature, finite-density Thomas-Fermi model. This approach corresponds to an average atom in local thermodynamic equilibrium. In comparison to isolated-neutral-atom results we observe general suppression of cross sections and a particular suppression in the tip region of the spectrum. Within this model, both superscreening and shape resonances are found in the circumstances of extreme density. At more normal densities and except for the soft-photon end, the spectrum at these energies for an atom in a hot plasma (characterized by an average degree of ionization) can be well represented by the spectrum of the corresponding isolated ion, which has a similar potential shape at the distances which characterize the process

  17. Oxidation of Inconel 625 superalloy upon treatment with oxygen or hydrogen plasma at high temperature

    Czech Academy of Sciences Publication Activity Database

    Vesel, A.; Drenik, A.; Elersic, K.; Mozetič, M.; Kovač, J.; Gyergyek, T.; Stöckel, Jan; Varju, Jozef; Pánek, Radomír; Balat-Pichelin, M.

    2014-01-01

    Roč. 305, June (2014), s. 674-682 ISSN 0169-4332 R&D Projects: GA MŠk(CZ) LM2011021 Institutional support: RVO:61389021 Keywords : Inconel * Oxidation * High temperature * Oxygen plasma * Hydrogen plasma Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 2.711, year: 2014 https://www.sciencedirect.com/science/article/pii/S0169433214007119

  18. Plasma properties and atomic processes at medium and high pressures

    International Nuclear Information System (INIS)

    Drawin, H.W.

    1979-01-01

    When the state of a plasma deviates from local thermodynamic equilibrium (L.T.E.) the equilibrium relations cannot be applied. The thermodynamic properties must then be described on the basis of models in which the individual atomic properties and elementary reactions intervene. The first part of the paper gives a schematic description of a plasma suffering power input, power losses and external constraints in the form of initial and boundary conditions. The rate equations for particle density, momentum and energy of open systems are summarized, including nuclear reactions. The second part gives a review of the progress made in understanding the properties of special types of non-L.T.E. plasmas such as glow discharge plasmas, negative ion plasmas (with application to the physics of SF 6 circuit-breakers) and Tokamak plasmas on the basis of these rate equations

  19. Physics of Collisional Plasmas Introduction to High-Frequency Discharges

    CERN Document Server

    Moisan, Michel

    2012-01-01

    The Physics of Collisional Plasmas deals with the plasma physics of interest to laboratory research and industrial applications, such as lighting, fabrication of microelectronics, destruction of greenhouse gases. Its emphasis is on explaining the physical mechanisms, rather than the detailed mathematical description and theoretical analysis. At the introductory level, it is important to convey the characteristic physical phenomena of plasmas, before addressing the ultimate formalism of kinetic theory, with its microscopic, statistical mechanics approach. To this aim, this text translates the physical phenomena into more tractable equations, using the hydrodynamic model; this considers the plasma as a fluid, in which the macroscopic physical parameters are the statistical averages of the microscopic (individual) parameters. This book is an introduction to the physics of collisional plasmas, as opposed to plasmas in space. It is intended for graduate students in physics and engineering . The first chapter intr...

  20. Stability in high gain plasmas in DIII-D

    International Nuclear Information System (INIS)

    Lazarus, E.A.; Houlberg, W.A.; Murakami, M.; Wade, M.R.

    1996-10-01

    Fusion power gain has been increased by a factor of 3 in DIII-D plasmas through the use of strong discharge shaping and tailoring of the pressure and current density profiles. H-mode plasmas with weak or negative central magnetic shear are found to have neoclassical ion confinement throughout most of the plasma volume. Improved MHD stability is achieved by controlling the plasma pressure profile width. The highest fusion power gain Q (ratio of fusion power to input power) in deuterium plasmas was 0.0015, which extrapolates to an equivalent Q of 0.32 in a deuterium-tritium plasma and is similar to values achieved in tokamaks of larger size and magnetic fields

  1. Transport of high fluxes of hydrogen plasma in a linear plasma generator

    NARCIS (Netherlands)

    Vijvers, W.A.J.; Al, R.S.; Lopes Cardozo, N.J.; Goedheer, W.J.; Groot, de B.; Kleyn, A.W.; Meiden, van der H.J.; Peppel, van de R.J.E.; Schram, D.C.; Shumack, A.E.; Westerhout, J.; Rooij, van G.J.; Schmidt, J.; Simek, M.; Pekarek, S.; Prukner, V.

    2007-01-01

    A study was made to quantify the losses during the convective hydrogen plasma transport in the linear plasma generator Pilot-PSI due to volume recombination. A transport efficiency of 35% was achieved at neutral background pressures below ~7 Pa in a magnetic field of 1.2 T. This efficiency decreased

  2. The binding of 125I-fibrinogen to blood platelets in patients with chronic uraemia

    International Nuclear Information System (INIS)

    Komarnicki, M.; Zozulinska, M.; Zawilska, K.

    1987-01-01

    The binding of 125 I-fibrinogen to blood platelets was assessed in 41 patients with chronic uremia. The study was performed in three groups of subjects: treated conservatively, with hemodialysis and with peritoneal dialysis. Platelets from uremic patients were shown to be more susceptible to fibrinogen binding than platelets from healthy subjects. (author)

  3. A study on human serum albumin influence on glycation of fibrinogen

    International Nuclear Information System (INIS)

    Kielmas, Martyna; Szewczuk, Zbigniew; Stefanowicz, Piotr

    2013-01-01

    Highlights: •The glycation of fibrinogen was investigated by isotopic labeling method. •The potential glycation sites in fibrinogen were identified. •Human serum albumin (HSA) inhibits the glycation of fibrinogen. •The effect of HSA on fibrinogen glycation is sequence-dependent. -- Abstract: Although in vivo glycation proceeds in complex mixture of proteins, previous studies did not take in consideration the influence of protein–protein interaction on Maillard reaction. The aim of our study was to test the influence of human serum albumin (HSA) on glycation of fibrinogen. The isotopic labeling using [ 13 C 6 ] glucose combined with LC-MS were applied as tool for identification possible glycation sites in fibrinogen and for evaluation the effect of HSA on the glycation level of selected amino acids in fibrinogen. The obtained data indicate that the addition of HSA protects the fibrinogen from glycation. The level of glycation in presence of HSA is reduced by 30–60% and depends on the location of glycated residue in sequence of protein

  4. Positive imaging of venous thrombi and thromboemboli with Ga-67 DFO-DAS-fibrinogen

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Kazutaka; Senda, Michio; Fujita, Toru; Yonekura, Yoshiharu; Kumada, Kaoru; Yokoyama, Akira; Torizuka, Kanji

    1988-05-01

    A newly developed thrombus imaging agent, /sup 67/Ga-DFO-DAS-fibrinogen (/sup 67/Ga-fibrinogen), was used for 22 studies in 20 cases of suspected deep venous thrombosis. Increased accumulation of /sup 67/Ga-fibrinogen in venous thrombi was depicted at 48 h after injection in 10 of the 15 cases (10 of 17 studies) who showed abnormal findings in radionuclide venography. A hot spot in the lung emboli was visualized in two cases. Seven of the eight cases having anticoagulant therapy showed increased /sup 67/Ga-fibrinogen uptake, while follow-up /sup 67/Ga-fibrinogen scintigraphy after the administration of heparin and urokinase did not reveal an abnormal hot spot in one case. /sup 67/Ga-fibrinogen can be made available simply by adding /sup 67/Ga solution to a vial containing fibrinogen-DAS-DFO conjugate. In conclusion, /sup 67/Ga-fibrinogen is considered to be a promising agent for detecting active venous thrombi and to assess the effect of anticoagulant therapy.

  5. A study on human serum albumin influence on glycation of fibrinogen

    Energy Technology Data Exchange (ETDEWEB)

    Kielmas, Martyna; Szewczuk, Zbigniew; Stefanowicz, Piotr, E-mail: Piotr.stefanowicz@chem.uni.wroc.pl

    2013-09-13

    Highlights: •The glycation of fibrinogen was investigated by isotopic labeling method. •The potential glycation sites in fibrinogen were identified. •Human serum albumin (HSA) inhibits the glycation of fibrinogen. •The effect of HSA on fibrinogen glycation is sequence-dependent. -- Abstract: Although in vivo glycation proceeds in complex mixture of proteins, previous studies did not take in consideration the influence of protein–protein interaction on Maillard reaction. The aim of our study was to test the influence of human serum albumin (HSA) on glycation of fibrinogen. The isotopic labeling using [{sup 13}C{sub 6}] glucose combined with LC-MS were applied as tool for identification possible glycation sites in fibrinogen and for evaluation the effect of HSA on the glycation level of selected amino acids in fibrinogen. The obtained data indicate that the addition of HSA protects the fibrinogen from glycation. The level of glycation in presence of HSA is reduced by 30–60% and depends on the location of glycated residue in sequence of protein.

  6. Silicon micromachining using a high-density plasma source

    International Nuclear Information System (INIS)

    McAuley, S.A.; Ashraf, H.; Atabo, L.; Chambers, A.; Hall, S.; Hopkins, J.; Nicholls, G.

    2001-01-01

    Dry etching of Si is critical in satisfying the demands of the micromachining industry. The micro-electro-mechanical systems (MEMS) community requires etches capable of high aspect ratios, vertical profiles, good feature size control and etch uniformity along with high throughput to satisfy production requirements. Surface technology systems' (STS's) high-density inductively coupled plasma (ICP) etch tool enables a wide range of applications to be realized whilst optimizing the above parameters. Components manufactured from Si using an STS ICP include accelerometers and gyroscopes for military, automotive and domestic applications. STS's advanced silicon etch (ASE TM ) has also allowed the first generation of MEMS-based optical switches and attenuators to reach the marketplace. In addition, a specialized application for fabricating the next generation photolithography exposure masks has been optimized for 200 mm diameter wafers, to depths of ∼750 μm. Where the profile is not critical, etch rates of greater than 8 μm min -1 have been realized to replace previous methods such as wet etching. This is also the case for printer applications. Specialized applications that require etching down to pyrex or oxide often result in the loss of feature size control at the interface; this is an industry wide problem. STS have developed a technique to address this. The rapid progression of the industry has led to development of the STS ICP etch tool, as well as the process. (author)

  7. Coaxial plasma thrusters for high specific impulse propulsion

    Science.gov (United States)

    Schoenberg, Kurt F.; Gerwin, Richard A.; Barnes, Cris W.; Henins, Ivars; Mayo, Robert; Moses, Ronald, Jr.; Scarberry, Richard; Wurden, Glen

    1991-01-01

    A fundamental basis for coaxial plasma thruster performance is presented and the steady-state, ideal MHD properties of a coaxial thruster using an annular magnetic nozzle are discussed. Formulas for power usage, thrust, mass flow rate, and specific impulse are acquired and employed to assess thruster performance. The performance estimates are compared with the observed properties of an unoptimized coaxial plasma gun. These comparisons support the hypothesis that ideal MHD has an important role in coaxial plasma thruster dynamics.

  8. Mapping high-latitude plasma convection with coherent HF radars

    International Nuclear Information System (INIS)

    Ruohoniemi, J.M.; Greenwald, R.A.; Baker, K.B.; Villain, J.-P.; Hanuise, C.; Kelly, J.

    1989-01-01

    In this decade, a new technique for the study of ionosphere electrodynamics has been implemented in an evolving generation of high-latitude HF radars. Coherent backscatter from electron density irregularities at F region altitudes is utilized to observe convective plasma motion. The electronic beam forming and scanning capabilities of the radars afford an excellent combination of spatial (∼50 km) and temporal (∼1 min) resolution of the large-scale (∼10 6 km 2 ) convection pattern. In this paper, we outline the methods developed to synthesize the HF radar data into two-dimensional maps of convection velocity. Although any single radar can directly measure only the line-of-sight, or radial, component of the plasma motion, the convection pattern is sometimes so uniform and stable that scanning in azimuth serves to determine the transverse component as well. Under more variable conditions, data from a second radar are necessary to unambiguously resolve velocity vectors. In either case, a limited region of vector solution can be expanded into contiguous areas of single-radar radial velocity data by noting that the convection must everywhere be divergence-free, i.e., ∇·v=0. It is thus often possible to map velocity vectors without extensive second-radar coverage. We present several examples of two-dimensional velocity maps. These show instances of L shell-aligned flow in the dusk sector, the reversal of convection near magnetic midnight, and counterstreaming in the dayside cleft. We include a study of merged coherent and incoherent radar data that illustrates the applicability of these methods to other ionospheric radar systems. copyright American Geophysical Union 1989

  9. Characterization of Wet Air Plasma Jet Powered by Sinusoidal High Voltage and Nanosecond Pulses for Plasma Agricultural Application

    Science.gov (United States)

    Takashima, Keisuke; Shimada, Keisuke; Konishi, Hideaki; Kaneko, Toshiro

    2015-09-01

    Not only for the plasma sterilization but also for many of plasma life-science applications, atmospheric pressure plasma devices that allowed us to control its state and reactive species production are deserved to resolve the roles of the chemical species. Influence of the hydroxyl radical and ozone on germination of conidia of a strawberry pathogen is presented. Water addition to air plasma jet significantly improves germination suppression performance, while measured reactive oxygen species (ROS) are reduced. Although the results show a negative correlation between ROS and the germination suppression, this infers the importance of chemical composition generated by plasma. For further control of the plasma product, a plasma jet powered by sinusoidal high voltage and nanosecond pulses is developed and characterized with the voltage-charge Lissajous. Control of breakdown phase and discharge power by pulse-imposed phase is presented. This work is supported by JSPS KAKENHI Grant-in-Aid for Young Scientists (B) Grant Number 15K17480 and Exploratory Research Grant Number 23644199.

  10. Association of fibrinogen with HbA1C in diabetic foot ulcer

    Science.gov (United States)

    Pase, M. A.; Gatot, D.; Lindarto, D.

    2018-03-01

    Fibrinogen is one of the inflammatory markers of vascular changes and endothelial dysfunction in diabetic patients. The aim of this study to associate serum fibrinogen levels with HbA1C in diabetic foot ulcer (DFU). This study was cross-sectional and retrospective in DFU patients from January to July 2017 in Haji Adam Malik Central General Hospital. The patients enrolled in the study were T2DM with DFU as a complication. The grading of DFU was evaluated according to the Wagner’s Classification. Serum fibrinogen level, HbA1C and ankle-brachial index (ABI) were carried out directly in the patients. Fibrinogen serum levels were found significantly with HbA1C (P=0.001, r=0.387) and ABI (P=0.008, r=-0.454). Fibrinogen serum levels in DFU patients were positively correlated with HbA1C and significantly higher in patients with poor glycemic control.

  11. Modelling deuterium release from tungsten after high flux high temperature deuterium plasma exposure

    Energy Technology Data Exchange (ETDEWEB)

    Grigorev, Petr, E-mail: grigorievpit@gmail.com [SCK-CEN, Nuclear Materials Science Institute, Boeretang 200, Mol, 2400 (Belgium); Ghent University, Applied Physics EA17 FUSION-DC, St. Pietersnieuwstraat, 41 B4, B-9000, Gent (Belgium); Department of Experimental Nuclear Physics K-89, Institute of Physics, Nanotechnologies, and Telecommunications, Peter the Great St. Petersburg Polytechnic University, St. Petersburg (Russian Federation); Matveev, Dmitry [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH, Trilateral Euregio Cluster, 52425, Jülich (Germany); Bakaeva, Anastasiia [SCK-CEN, Nuclear Materials Science Institute, Boeretang 200, Mol, 2400 (Belgium); Department of Applied Physics, Ghent University (Belgium); Terentyev, Dmitry [SCK-CEN, Nuclear Materials Science Institute, Boeretang 200, Mol, 2400 (Belgium); Zhurkin, Evgeny E. [Department of Experimental Nuclear Physics K-89, Institute of Physics, Nanotechnologies, and Telecommunications, Peter the Great St. Petersburg Polytechnic University, St. Petersburg (Russian Federation); Van Oost, Guido [Ghent University, Applied Physics EA17 FUSION-DC, St. Pietersnieuwstraat, 41 B4, B-9000, Gent (Belgium); Noterdaeme, Jean-Marie [Ghent University, Applied Physics EA17 FUSION-DC, St. Pietersnieuwstraat, 41 B4, B-9000, Gent (Belgium); Max-Planck-Institut für Plasmaphysik, Garching (Germany)

    2016-12-01

    Tungsten is a primary candidate for plasma facing materials for future fusion devices. An important safety concern in the design of plasma facing components is the retention of hydrogen isotopes. Available experimental data is vast and scattered, and a consistent physical model of retention of hydrogen isotopes in tungsten is still missing. In this work we propose a model of non-equilibrium hydrogen isotopes trapping under fusion relevant plasma exposure conditions. The model is coupled to a diffusion-trapping simulation tool and is used to interpret recent experiments involving high plasma flux exposures. From the computational analysis performed, it is concluded that high flux high temperature exposures (T = 1000 K, flux = 10{sup 24} D/m{sup 2}/s and fluence of 10{sup 26} D/m{sup 2}) result in generation of sub-surface damage and bulk diffusion, so that the retention is driven by both sub-surface plasma-induced defects (bubbles) and trapping at natural defects. On the basis of the non-equilibrium trapping model we have estimated the amount of H stored in the sub-surface region to be ∼10{sup −5} at{sup −1}, while the bulk retention is about 4 × 10{sup −7} at{sup −1}, calculated by assuming the sub-surface layer thickness of about 10 μm and adjusting the trap concentration to comply with the experimental results for the integral retention.

  12. Calculation of high-pressure argon plasma parameters produced by excimer laser

    International Nuclear Information System (INIS)

    Tsuda, Norio; Yamada, Jun

    2000-01-01

    When a XeCl excimer laser light was focused in a high-pressure argon gas up to 150 atm, a dense plasma developed not only backward but also forward. It is important to study on the electron density and temperature of the laser-induced plasma in the high-pressure gas. The electron density and temperature in high-pressure argon plasma produced by XeCl excimer laser has been calculated and compared with the experimental data. (author)

  13. Results from core-edge experiments in high Power, high performance plasmas on DIII-D

    Directory of Open Access Journals (Sweden)

    T.W. Petrie

    2017-08-01

    Full Text Available Significant challenges to reducing divertor heat flux in highly powered near-double null divertor (DND hybrid plasmas, while still maintaining both high performance metrics and low enough density for application of RF heating, are identified. For these DNDs on DIII-D, the scaling of the peak heat flux at the outer target (q⊥P ∝ [PSOL x IP] 0.92 for PSOL= 8−19MW and IP= 1.0–1.4MA, and is consistent with standard ITPA scaling for single-null H-mode plasmas. Two divertor heat flux reduction methods were tested. First, applying the puff-and-pump radiating divertor to DIII-D plasmas may be problematical at high power and H98 (≥ 1.5 due to improvement in confinement time with deuterium gas puffing which can lead to unacceptably high core density under certain conditions. Second, q⊥P for these high performance DNDs was reduced by ≈35% when an open divertor is closed on the common flux side of the outer divertor target (“semi-slot” but also that heating near the slot opening is a significant source for impurity contamination of the core.

  14. THE TURBULENT DYNAMO IN HIGHLY COMPRESSIBLE SUPERSONIC PLASMAS

    Energy Technology Data Exchange (ETDEWEB)

    Federrath, Christoph [Research School of Astronomy and Astrophysics, The Australian National University, Canberra, ACT 2611 (Australia); Schober, Jennifer [Universität Heidelberg, Zentrum für Astronomie, Institut für Theoretische Astrophysik, Albert-Ueberle-Strasse 2, D-69120 Heidelberg (Germany); Bovino, Stefano; Schleicher, Dominik R. G., E-mail: christoph.federrath@anu.edu.au [Institut für Astrophysik, Georg-August-Universität Göttingen, Friedrich-Hund-Platz 1, D-37077 Göttingen (Germany)

    2014-12-20

    The turbulent dynamo may explain the origin of cosmic magnetism. While the exponential amplification of magnetic fields has been studied for incompressible gases, little is known about dynamo action in highly compressible, supersonic plasmas, such as the interstellar medium of galaxies and the early universe. Here we perform the first quantitative comparison of theoretical models of the dynamo growth rate and saturation level with three-dimensional magnetohydrodynamical simulations of supersonic turbulence with grid resolutions of up to 1024{sup 3} cells. We obtain numerical convergence and find that dynamo action occurs for both low and high magnetic Prandtl numbers Pm = ν/η = 0.1-10 (the ratio of viscous to magnetic dissipation), which had so far only been seen for Pm ≥ 1 in supersonic turbulence. We measure the critical magnetic Reynolds number, Rm{sub crit}=129{sub −31}{sup +43}, showing that the compressible dynamo is almost as efficient as in incompressible gas. Considering the physical conditions of the present and early universe, we conclude that magnetic fields need to be taken into account during structure formation from the early to the present cosmic ages, because they suppress gas fragmentation and drive powerful jets and outflows, both greatly affecting the initial mass function of stars.

  15. Treatment of Wastewater with High Conductivity by Pulsed Discharge Plasma

    International Nuclear Information System (INIS)

    Wang Zhaojun; Jiang Song; Liu Kefu

    2014-01-01

    A wastewater treatment system was established by means of pulsed dielectric barrier discharge (DBD). The main advantage of this system is that the wastewater is employed as one of the electrodes for the degradation of rhodamine B, which makes use of the high conductivity and lessenes its negative influence on the discharge process. At the same time, the reactive species like ozone and ultraviolet (UV) light generated by the DBD can be utilized for the treatment of wastewater. The effects of some factors like conductivity, peak pulse voltage, discharge frequency and pH values were investigated. The results show that the combination of these reactive species could enhance the degradation of the dye while the ozone played the most important role in the process. The degradation efficiency was enhanced with the increase of energy supplied. The reduction in the concentration of rhodamine B was much more effective with high solution conductivity; under the highest conductivity condition, the degradation rate could rise to 99%. (plasma technology)

  16. Design of Tokamak plasma with high Tc superconducting coils

    International Nuclear Information System (INIS)

    Uchimoto, T.; Miya, K.; Yoshida, Y.; Yamada, T.

    1999-01-01

    This paper presents a design of tokamak plasma in light of how the small ignited tokamak is possible with use of the HTSC coils as plasma stabilizer. The same data base and formulas as ITER are here used and any innovative technology other than the HTSC stabilizing coils is not assumed. (author)

  17. Controllers for high-performance nuclear fusion plasmas

    NARCIS (Netherlands)

    Baar, de M.R.

    2012-01-01

    A succesful nuclear fusion reactor will confine plasma at hig temperatures and densities, with low thermal losses. The workhorse of the nuclear fusion community is the tokamak, a toroidal device in which plasmas are confined by poloidal and toroidal magnetic fields. Ideally, the confirming magnetic

  18. High density internal transport barriers for burning plasma operation

    Energy Technology Data Exchange (ETDEWEB)

    Ridolfini, V Pericoli [Associazione EURATOM-ENEA sulla Fusione, CR Frascati, Rome (Italy); Barbato, E [Associazione EURATOM-ENEA sulla Fusione, CR Frascati, Rome (Italy); Buratti, P [Associazione EURATOM-ENEA sulla Fusione, CR Frascati, Rome (Italy)] (and others)

    2005-12-15

    A tokamak plasma with internal transport barriers (ITBs) is the best candidate for a steady ITER operation, since the high energy confinement allows working at plasma currents (I{sub p}) lower than the reference scenario. To build and sustain an ITB at the ITER high density ({>=}10{sup 20} m{sup -3}) and largely dominant electron (e{sup -}) heating is not trivial in most existing tokamaks. FTU can instead meet both requests, thanks to its radiofrequency heating systems, lower hybrid (LH, up to 1.9 MW) and electron cyclotron (EC up to 1.2 MW). By the combined use of them, ITBs are obtained up to peak densities n{sub e0} > 1.3 x 10{sup 20} m{sup -3}, with central e{sup -} temperatures T{sub e0} {approx} 5.5 keV, and are sustained for as long as the heating pulse is applied (>35 confinement times, {tau}{sub E}). At n{sub e0} {approx} 0.8 x 10{sup 20} m{sup -3} T{sub e0} can be larger than 11 keV. Almost full current drive (CD) and an overall good steadiness is attained within about one {tau}{sub E}, 20 times faster than the ohmic current relaxation time. The ITB extends over a central region with an almost flat or slightly reversed q profile and q{sub min} {approx} 1.3 that is fully sustained by off-axis lower hybrid current drive. Consequent to this is the beneficial good alignment of the bootstrap current, generated by the ITB large pressure gradients, with the LH driven current. Reflectometry shows a clear change in the turbulence close to the ITB radius, consistent with the reduced e{sup -} transport. Ions (i{sup +}) are significantly heated via collisions, but thermal equilibrium with electrons cannot be attained since the e{sup -}-i{sup +} equipartition time is always 4-5 times longer than {tau}{sub E}. No degradation of the overall ion transport, rather a reduction of the i{sup +} heat diffusivity, is observed inside the ITB. The global confinement has been improved up to 1.6 times over the scaling predictions. The ITB radius can be controlled by adjusting the

  19. New approach to 3-D, high sensitivity, high mass resolution space plasma composition measurements

    International Nuclear Information System (INIS)

    McComas, D.J.; Nordholt, J.E.

    1990-01-01

    This paper describes a new type of 3-D space plasma composition analyzer. The design combines high sensitivity, high mass resolution measurements with somewhat lower mass resolution but even higher sensitivity measurements in a single compact and robust design. While the lower resolution plasma measurements are achieved using conventional straight-through time-of-flight mass spectrometry, the high mass resolution measurements are made by timing ions reflected in a linear electric field (LEF), where the restoring force that an ion experiences is proportional to the depth it travels into the LEF region. Consequently, the ion's equation of motion in that dimension is that of a simple harmonic oscillator and its travel time is simply proportional to the square root of the ion's mass/charge (m/q). While in an ideal LEF, the m/q resolution can be arbitrarily high, in a real device the resolution is limited by the field linearity which can be achieved. In this paper we describe how a nearly linear field can be produced and discuss how the design can be optimized for various different plasma regimes and spacecraft configurations

  20. The application of high-speed photography and spectrography for investigations of erosive pulsed plasma streams

    International Nuclear Information System (INIS)

    Kiselevskiy, L.I.; Minko, L.Ja.

    The extensive information of pulsed plasma dynamic processes related to formation and interaction of plasma streams with a surrounding medium and obstacles is obtained with the help of high-speed photo and spectrography. The wave structure of pulsed supersonic under-expanded erosive plasma jets is studied. Some physical processes which are due to interactions of laser radiation with the laser-produced erosive plasma and of this plasma with a surrounding medium are investigated. The wide possibilities of frame photography of spectra quantitative spectroscopic investigations of fast-proceeding plasma processes are shown on the basis of joint use of high-speed photographic apparatus (type SFR) and standard spectrographs. The radial distribution of charged-particle concentrations at separate moments of time is obtained from the broadening of spectral lines at the brightness of the continuous spectrum of an erosive plasma jet from a pulsed accelerator

  1. Interaction of high power ultrashort laser pulses with plasmas

    International Nuclear Information System (INIS)

    Geissler, M.

    2000-12-01

    The invention of short laser-pulses has opened a vast application range from testing ultra high-speed semiconductor devices to precision material processing, from triggering and tracing chemical reactions to sophisticated surgical applications in opthalmology and neurosurgery. In physical science, ultrashort light pulses enable researchers to follow ultrafast relaxation processes in the microcosm on time scale never before accessible and study light-matter-interactions at unprecedented intensity levels. The aim of this thesis is to investigate the interaction of ultrashort high power laser pulses with plasmas for a broad intensity range. First the ionization of atoms with intense laser fields is investigated. For sufficient strong and low frequent laser pulses, electrons can be removed from the core by a tunnel process through a potential barrier formed by the electric field of the laser. This mechanism is described by a well-established theory, but the interaction of few-cycle laser pulses with atoms can lead to regimes where the tunnel theory loses its validity. This regime is investigated and a new description of the ionization is found. Although the ionization plays a major role in many high-energy laser processes, there exist no simple and complete model for the evolution of laser pulses in field-ionizing media. A new propagation equation and the polarization response for field-ionizing media are presented and the results are compared with experimental data. Further the interaction of high power laser radiation with atoms result in nonlinear response of the electrons. The spectrum of this induced nonlinear dipole moment reaches beyond visible wavelengths into the x-ray regime. This effect is known as high harmonic generation (HHG) and is a promising tool for the generation of coherent shot wavelength radiation, but the conversions are still not efficient enough for most practical applications. Phase matching schemes to overcome the limitation are discussed

  2. High-Density Plasma-Induced Etch Damage of GaN

    International Nuclear Information System (INIS)

    Baca, A.G.; Han, J.; Lester, L.F.; Pearton, S.J.; Ren, F.; Shul, R.J.; Willison, C.G.; Zhang, L.; Zolper, J.C.

    1999-01-01

    Anisotropic, smooth etching of the group-III nitrides has been reported at relatively high rates in high-density plasma etch systems. However, such etch results are often obtained under high de-bias and/or high plasma flux conditions where plasma induced damage can be significant. Despite the fact that the group-III nitrides have higher bonding energies than more conventional III-V compounds, plasma-induced etch damage is still a concern. Attempts to minimize such damage by reducing the ion energy or increasing the chemical activity in the plasma often result in a loss of etch rate or anisotropy which significantly limits critical dimensions and reduces the utility of the process for device applications requiring vertical etch profiles. It is therefore necessary to develop plasma etch processes which couple anisotropy for critical dimension and sidewall profile control and high etch rates with low-damage for optimum device performance. In this study we report changes in sheet resistance and contact resistance for n- and p-type GaN samples exposed to an Ar inductively coupled plasma (ICP). In general, plasma-induced damage was more sensitive to ion bombardment energies as compared to plasma flux. In addition, p-GaN was typically more sensitive to plasma-induced damage as compared to n-GaN

  3. US-Japan workshop Q-181 on high heat flux components and plasma-surface interactions for next devices: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    McGrath, R.T. [ed.] [Sandia National Labs., Albuquerque, NM (United States); Yamashina, T. [ed.] [Hokkadio Univ. (Japan)

    1994-04-01

    This report contain viewgraphs of papers from the following sessions: plasma facing components issues for future machines; recent PMI results from several tokamaks; high heat flux technology; plasma facing components design and applications; plasma facing component materials and irradiation damage; boundary layer plasma; plasma disruptions; conditioning and tritium; and erosion/redeposition.

  4. US-Japan workshop Q-181 on high heat flux components and plasma-surface interactions for next devices: Proceedings

    International Nuclear Information System (INIS)

    McGrath, R.T.; Yamashina, T.

    1994-04-01

    This report contain viewgraphs of papers from the following sessions: plasma facing components issues for future machines; recent PMI results from several tokamaks; high heat flux technology; plasma facing components design and applications; plasma facing component materials and irradiation damage; boundary layer plasma; plasma disruptions; conditioning and tritium; and erosion/redeposition

  5. Characterization Of High Explosives Detonations Via Laser-Induced Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Villa-Aleman, E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-08

    One objective of the Department of Energy’s National Security Administration is to develop technologies that can help the United States government to detect foreign nuclear weapons development activities. The realm of high explosive (HE) experiments is one of the key areas to assess the nuclear ambitions of a country. SRNL has participated in the collection of particulates from HE experiments and characterized the material with the purpose to correlate particulate matter with HE. Since these field campaigns are expensive, on-demand simulated laboratory-scale explosion experiments are needed to further our knowledge of the chemistry and particle formation in the process. Our goal is to develop an experimental test bed in the laboratory to test measurement concepts and correlate particle formation processes with the observables from the detonation fireball. The final objective is to use this knowledge to tailor our experimental setups in future field campaigns. The test bed uses pulsed laser-induced plasmas to simulate micro-explosions, with the intent to study the temporal behavior of the fireball observed in field tests. During FY15, a plan was prepared and executed which assembled two laser ablation systems, procured materials for study, and tested a Step-Scan Fourier Transform Infrared Spectrometer (SS-FTIR). Designs for a shadowgraph system for shock wave analysis, design for a micro-particulate collector from ablated pulse were accomplished. A novel spectroscopic system was conceived and a prototype system built for acquisition of spectral/temporal characterization of a high speed event such as from a high explosive detonation. Experiments and analyses will continue into FY16.

  6. Anticorrelated Emission of High Harmonics and Fast Electron Beams From Plasma Mirrors.

    Science.gov (United States)

    Bocoum, Maïmouna; Thévenet, Maxence; Böhle, Frederik; Beaurepaire, Benoît; Vernier, Aline; Jullien, Aurélie; Faure, Jérôme; Lopez-Martens, Rodrigo

    2016-05-06

    We report for the first time on the anticorrelated emission of high-order harmonics and energetic electron beams from a solid-density plasma with a sharp vacuum interface-plasma mirror-driven by an intense ultrashort laser pulse. We highlight the key role played by the nanoscale structure of the plasma surface during the interaction by measuring the spatial and spectral properties of harmonics and electron beams emitted by a plasma mirror. We show that the nanoscale behavior of the plasma mirror can be controlled by tuning the scale length of the electron density gradient, which is measured in situ using spatial-domain interferometry.

  7. Supersonic plasma flow between high latitude conjugate ionospheres

    International Nuclear Information System (INIS)

    Roesler, G.

    1975-01-01

    The polar wind problem has been investigated for closed field lines in situations where one of the two conjugate ionospheric regions is fully illuminated by the sun and the other darkness (solstices at high latitudes). A supersonic flow between hemispheres is possible; the magnetospheric part of this flow must be symmetric with respect to the equator. The daytime fluxes are proportional to the neutral hydrogen density. Fluxes of the order of 10 8 cm -2 sec -1 are only possible with density considerably higher than given by CIRA models. For stationary solutions higher flow speeds are needed on the dark side than provided from the illuminated side. It is concluded that shock waves with upward velocities of about 5 km/sec would form above the dark ionosphere. This implies a reduction by a factor of 3 to 5 of the plasma influx into the dark hemisphere, whereby F-layer densities of only up to 2 x 10 4 cm -3 can be maintained. (orig.) [de

  8. Miniaturized heat flux sensor for high enthalpy plasma flow characterization

    International Nuclear Information System (INIS)

    Gardarein, Jean-Laurent; Battaglia, Jean-Luc; Lohlec, Stefan; Jullien, Pierre; Van Ootegemd, Bruno; Couzie, Jacques; Lasserre, Jean-Pierre

    2013-01-01

    An improved miniaturized heat flux sensor is presented aiming at measuring extreme heat fluxes of plasma wind tunnel flows. The sensor concept is based on an in-depth thermocouple measurement with a miniaturized design and an advanced calibration approach. Moreover, a better spatial estimation of the heat flux profile along the flow cross section is realized with this improved small sensor design. Based on the linearity assumption, the heat flux is determined using the impulse response of the sensor relating the heat flux to the temperature of the embedded thermocouple. The non-integer system identification (NISI) procedure is applied that allows a calculation of the impulse response from transient calibration measurements with a known heat flux of a laser source. The results show that the new sensor leads to radially highly resolved heat flux measurement for a flow with only a few centimetres in diameter, the so far not understood non-symmetric heat flux profiles do not occur with the new sensor design. It is shown that this former effect is not a physical effect of the flow, but a drawback of the classical sensor design. (authors)

  9. Laser-produced dense plasma in extremely high pressure gas and its application to a plasma-bridged gap switch

    International Nuclear Information System (INIS)

    Yamada, J.; Okuda, A.

    1989-01-01

    When an extremely high pressure gas is irradiated by an intense laser light, a dense plasma produced at the focal spot moves towards the focusing lens with a high velocity. Making use of this phenomenon, a new plasma-bridged gap switch is proposed and its switching characteristics is experimentally examined. From the experiments, it is confirmed that the switching time is almost constant with the applied voltage only when the focal spot is just on the positive electrode, indicating that the bridging of gap is caused by the laser light. (author)

  10. Excitation of plasma waves by nonlinear currents induced by a high-frequency electromagnetic pulse

    Energy Technology Data Exchange (ETDEWEB)

    Grishkov, V. E.; Uryupin, S. A., E-mail: uryupin@sci.lebedev.ru [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation)

    2017-03-15

    Excitation of plasma waves by nonlinear currents induced by a high-frequency electromagnetic pulse is analyzed within the kinetic approach. It is shown that the most efficient source of plasma waves is the nonlinear current arising due to the gradient of the energy density of the high-frequency field. Generation of plasma waves by the drag current is usually less efficient but not negligibly small at relatively high frequencies of electron–ion collisions. The influence of electron collisions on the excitation of plasma waves by pulses of different duration is described quantitatively.

  11. Multi-fluid Approach to High-frequency Waves in Plasmas. III. Nonlinear Regime and Plasma Heating

    Science.gov (United States)

    Martínez-Gómez, David; Soler, Roberto; Terradas, Jaume

    2018-03-01

    The multi-fluid modeling of high-frequency waves in partially ionized plasmas has shown that the behavior of magnetohydrodynamic waves in the linear regime is heavily influenced by the collisional interaction between the different species that form the plasma. Here, we go beyond linear theory and study large-amplitude waves in partially ionized plasmas using a nonlinear multi-fluid code. It is known that in fully ionized plasmas, nonlinear Alfvén waves generate density and pressure perturbations. Those nonlinear effects are more pronounced for standing oscillations than for propagating waves. By means of numerical simulations and analytical approximations, we examine how the collisional interaction between ions and neutrals affects the nonlinear evolution. The friction due to collisions dissipates a fraction of the wave energy, which is transformed into heat and consequently raises the temperature of the plasma. As an application, we investigate frictional heating in a plasma with physical conditions akin to those in a quiescent solar prominence.

  12. The theta-pinch - a versatile tool for the generation and study of high temperature plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Hintz, E. [Inst. fuer Plasmaphysik, Forschungszentrum-Juelich GmbH (Germany)

    2004-07-01

    The more general technical and physical features of theta-pinches are described. Special field of their application are high-ss plasmas. Two examples are analysed and studied in more detail: a high density plasma near thermal equilibrium and a low density plasma far from equilibrium. The latter is of special interest for future investigations. Possibilities of field-reversed configurations are pointed out. (orig.)

  13. The theta-pinch - a versatile tool for the generation and study of high temperature plasmas

    International Nuclear Information System (INIS)

    Hintz, E.

    2004-01-01

    The more general technical and physical features of theta-pinches are described. Special field of their application are high-ss plasmas. Two examples are analysed and studied in more detail: a high density plasma near thermal equilibrium and a low density plasma far from equilibrium. The latter is of special interest for future investigations. Possibilities of field-reversed configurations are pointed out. (orig.)

  14. Physics and applications of high energy density plasmas. Extreme state driven by pulsed electromagnetic energy

    International Nuclear Information System (INIS)

    Horioka, Kazuhiko

    2002-06-01

    The papers presented at the symposium on ''Physics and application of high energy density plasmas, held December 20-21, 2001 at NIFS'' are collected in this proceedings. The topics covered in the meeting include dense z-pinches, plasma focus, intense charged particle beams, intense radiation sources, discharge pumped X-ray lasers, their diagnostics, and applications of them. The papers reflect the present status and trends in the research field of high energy density plasmas. (author)

  15. High energy particle acceleration by relativistic plasma waves

    International Nuclear Information System (INIS)

    Amiranoff, F.; Jacquet, F.; Mora, P.; Matthieussent, G.

    1991-01-01

    Accelerating schemes using plasmas, lasers or electron beams are proposed and compared to electron bunches in dielectric media or laser propagation through a slow wave structure made of liquid droplets. (L.C.J.A.). 33 refs, 20 figs

  16. Electron Cyclotron Resonance Heating of a High-Density Plasma

    DEFF Research Database (Denmark)

    Hansen, F. Ramskov

    1986-01-01

    Various schemes for electron cyclotron resonance heating of tokamak plasmas with the ratio of electron plasma frequency to electron cyclotron frequency, "»pe/^ce* larger than 1 on axis, are investigated. In particular, a mode conversion scheme is investigated using ordinary waves at the fundamental...... of the electron cyclotron frequency. These are injected obliquely from the outside of the tokamak near an optimal angle to the magnetic field lines. This method involves two mode conversions. The ordinary waves are converted into extraordinary waves near the plasma cut-off layer. The extraordinary waves...... are subsequently converted into electrostatic electron Bernstein waves at the upper hybrid resonance layer, and the Bernstein waves are completely absorbed close to the plasma centre. Results are presented from ray-tracinq calculations in full three-dimensional geometry using the dispersion function for a hot non...

  17. Laboratory of plasma studies. Papers on high power particle beams

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    This book contains paper on Exploding metal film active anode sources experiments on the Lion extractor Ion Diode; Long conductor time plasma opening switch experiments; and Focusing studies of an applied B r extraction diode on the Lion accelerator

  18. Active neutral particle diagnostics for high temperature plasma

    International Nuclear Information System (INIS)

    Tobita, Kenji

    1993-01-01

    This paper describes experimental studies related to active neutral particle diagnostics in the JT-60 tokamak. Detection efficiencies of a micro-channel plate (MCP), which has widely used in plasma diagnostics, were determined for ions and neutrals. Multi-step processes for a neutral beam is predicted to enhance the beam stopping cross section in a plasma. In order to confirm the predictions, shine-through for a hydrogen and for a helium beam was measured in the JT-60 ohmic plasmas. The measurements for a hydrogen beam resulted in the cross sectional enhancement in the beam stopping. The same experiment using a helium beam indicated that the cross sectional enhancement for helium was much smaller than that for hydrogen at almost same plasma parameters. Ion temperature diagnostic using active beam scattering was developed in data processing technique, in consideration of the device function of a neutral particle analyzer and in estimation of the effect of beam ion component. Fundamental experiments for detecting helium ions in a plasma were performed using two-electron transfer reaction between a helium atomic beam and helium ions, and the energy distribution and the density of the helium ions were determined. These experiments demonstrated promise of the two-electron transfer reaction as an alpha ash detection in a burning plasma. A parasitic neutral efflux accompanied by active beam injection was investigated. (J.P.N.)

  19. Clumping factor A-mediated virulence during Staphylococcus aureus infection is retained despite fibrinogen depletion.

    Science.gov (United States)

    Palmqvist, Niklas; Josefsson, Elisabet; Tarkowski, Andrzej

    2004-02-01

    Clumping factor A (ClfA), a fibrinogen-binding protein expressed on the Staphylococcus aureus cell surface, has previously been shown to act as a virulence factor in experimental septic arthritis. Although the interaction between ClfA and fibrinogen is assumed to be of importance for the virulence of S. aureus, this has not been demonstrated in any in vivo model of infection. Therefore, the objective of this study was to investigate the contribution of this interaction to ClfA-mediated virulence in murine S. aureus-induced arthritis. Ancrod, a serine protease with thrombin-like activity, was used to induce in vivo depletion of fibrinogen in mice. Ancrod treatment significantly aggravated septic arthritis following inoculation with a ClfA-expressing strain (Newman) compared to control treatment. Also, ancrod treatment tended to enhance the arthritis induced by a clfA mutant strain (DU5876), indicating that fibrinogen depletion exacerbates septic arthritis in a ClfA-independent manner. Most importantly, the ClfA-expressing strain was much more arthritogenic than the isogenic clfA mutant, following inoculation of fibrinogen-depleted mice. This finding indicates that the interaction between ClfA and free fibrinogen is not required for ClfA-mediated functions contributing to S. aureus virulence. It is conceivable that ClfA contributes to the virulence of S. aureus through interactions with other host ligands than fibrinogen.

  20. A randomized, double blind trial of prophylactic fibrinogen to reduce bleeding in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Mostafa Sadeghi

    2014-07-01

    Full Text Available BACKGROUND AND OBJECTIVES: Postoperative bleeding has a great clinical importance and can contribute to increased mortality and morbidity in patients undergoing coronary artery bypass graft surgery. In this prospective, randomized, double-blind study, we evaluated the effect of prophylactic administration of fibrinogen concentrate on post-coronary artery bypass graft surgery bleeding. METHODS: A total of 60 patients undergoing coronary artery bypass surgery were randomly divided into two groups. Patients in the fibrinogen group received 1 g of fibrinogen concentrate 30 min prior to the operation, while patients in the control group received placebo. Post-operative bleeding volumes, prothrombin time, partial thromboplastin time, INR, hemoglobin and transfused blood products in both groups were recorded. A strict red blood cell transfusion protocol was used in all patients. RESULTS: There were no significant differences between intra-operative packed red blood cells infusion in the studied groups (1.0 ± 1.4 in fibrinogen group, and 1.3 ± 1.1 in control group. Less postoperative bleeding was observed in the fibrinogen group (477 ± 143 versus 703 ± 179, p = 0.0001. Fifteen patients in the fibrinogen group and 21 in the control group required post-op packed red blood cells infusion (p = 0.094. No thrombotic event was observed through 72 h after surgery. CONCLUSION: Prophylactic fibrinogen reduces post-operative bleeding in patients undergoing coronary artery bypass graft.

  1. Simulation of cold plasma in a chamber under high- and low-frequency voltage conditions for a capacitively coupled plasma

    Institute of Scientific and Technical Information of China (English)

    Hao Daoxin; Cheng Jia; Ji Linhong; Sun Yuchun

    2012-01-01

    The characteristics of cold plasma,especially for a dual-frequency capacitively coupled plasma (CCP),play an important role for plasma enhanced chemical vapor deposition,which stimulates further studies using different methods.In this paper,a 2D fluid model was constructed for N2 gas plasma simulations with CFD-ACE+,a commercial multi-physical software package.First,the distributions of electric potential (Epot),electron number density (Ne),N number density (N) and electron temperature (Te) are described under the condition of high frequency (HF),13.56 MHz,HF voltage,300 V,and low-frequency (LF) voltage,0 V,particularly in the sheath.Based on this,the influence of HF on Ne is further discussed under different HF voltages of 200 V,300 V,400 V,separately,along with the influence of LF,0.3 MHz,and various LF voltages of 500 V,600 V,700 V.The results show that sheaths of about 3 mm are formed near the two electrodes,in which Epot and Te vary extensively with time and space,while in the plasma bulk Epot changes synchronously with an electric potential of about 70 V and Te varies only in a small range.N is also modulated by the radio frequency,but the relative change in N is small.Ne varies only in the sheath,while in the bulk it is steady at different time steps.So,by comparing Ne in the plasma bulk at the steady state,we can see that Ne will increase when HF voltage increases.Yet,Ne will slightly decrease with the increase of LF voltage.At the same time,the homogeneity will change in both x and y directions.So both HF and LF voltages should be carefully considered in order to obtain a high-density,homogeneous plasma.

  2. Laser Thomson scattering diagnostics of non-equilibrium high pressure plasmas

    International Nuclear Information System (INIS)

    Muraoka, K.; Uchino, K.; Bowden, M.D.; Noguchi, Y.

    2001-01-01

    For various applications of non-equilibrium high pressure plasmas, knowledge of electron properties, such as electron density, electron temperature and/or electron energy distribution function (eedf), is prerequisite for any rational approach to understanding physical and chemical processes occurring in the plasmas. For this purpose, laser Thomson scattering has been successfully applied for the first time to measure the electron properties in plasmas for excimer laser pumping and in microdischarges. Although this diagnostic technique is well established for measurements in high temperature plasmas, its applications to these glow discharge plasmas have had various inherent difficulties, such as a presence of high density neutral particles (>10 21 m -3 ) in the excimer laser pumping discharges and an extremely small plasma size (<0.1 mm) and the presence of nearby walls for microdischarges. These difficulties have been overcome and clear signals have been obtained. The measured results are presented and their implications in the respective discharge phenomena are discussed

  3. THE FLOCCULATION MAXIMUM (pH) OF FIBRINOGEN AND SOME OTHER BLOOD-CLOTTING REAGENTS. (RELATIVE TURBIDIMETRY WITH THE EVELYN PHOTOELECTRIC COLORIMETER).

    Science.gov (United States)

    Ferguson, J H

    1942-03-20

    By means of a novel adaptation of the Evelyn photoelectric colorimeter to the measurement of relative turbidities, the question of the flocculation maximum (F.M.) in acetate buffer solutions of varying pH and salt content has been studied on (a) an exceptionally stable prothrombin-free fibrinogen and its solutions after incipient thermal denaturation and incomplete tryptic proteolysis, (b) plasma, similarly treated, (c) prothrombin, thrombin, and (brain) thromboplastin solutions. All the fibrinogens show a remarkable uniformity of the precipitation pattern, viz. F.M. =4.7 (+/-0.2) pH in salt-containing buffer solutions and pH = 5.3 (+/-0.2) in salt-poor buffer (N/100 acetate). The latter approximates the isoelectric point (5.4) obtained by cataphoresis (14). There is no evidence that denaturation or digestion can produce any "second maximum." The data support the view that fibrin formation (under the specific influence of thrombin) is intrinsically unrelated to denaturation and digestion phenomena, although all three can proceed simultaneously in crude materials. A criticism is offered, therefore, of Wöhlisch's blood clotting theory. Further applications of the photoelectric colorimeter to coagulation problems are suggested, including kinetic study of fibrin formation and the assay of fibrinogen, with a possible sensitivity of 7.5 mg. protein in 100 cc. solution.

  4. Compatibility of advanced tokamak plasma with high density and high radiation loss operation in JT-60U

    International Nuclear Information System (INIS)

    Takenaga, H.; Asakura, N.; Kubo, H.; Higashijima, S.; Konoshima, S.; Nakano, T.; Oyama, N.; Ide, S.; Fujita, T.; Takizuka, T.; Kamada, Y.; Miura, Y.; Porter, G.D.; Rognlien, T.D.; Rensink, M.E.

    2005-01-01

    Compatibility of advanced tokamak plasmas with high density and high radiation loss has been investigated in both reversed shear (RS) plasmas and high β p H-mode plasmas with a weak positive shear on JT-60U. In the RS plasmas, the operation regime is extended to high density above the Greenwald density (n GW ) with high confinement (HH y2 >1) and high radiation loss fraction (f rad >0.9) by tailoring the internal transport barriers (ITBs). High confinement of HH y2 =1.2 is sustained even with 80% radiation from the main plasma enhanced by accumulated metal impurity. The divertor radiation is enhanced by Ne seeding and the ratio of the divertor radiation to the total radiation is increased from 20% without seeding to 40% with Ne seeding. In the high β p H-mode plasmas, high confinement (HH y2 =0.96) is maintained at high density (n-bar e /n GW =0.92) with high radiation loss fraction (f rad ∼1) by utilizing high-field-side pellets and Ar injections. The high n-bar e /n GW is obtained due to a formation of clear density ITB. Strong core-edge parameter linkage is observed, as well as without Ar injection. In this linkage, the pedestal β p , defined as β p ped =p ped /(B p 2 /2μ 0 ) where p ped is the plasma pressure at the pedestal top, is enhanced with the total β p . The radiation profile in the main plasma is peaked due to Ar accumulation inside the ITB and the measured central radiation is ascribed to Ar. The impurity transport analyses indicate that Ar accumulation by a factor of 2 more than the electron, as observed in the high β p H-mode plasma, is acceptable even with peaked density profile in a fusion reactor for impurity seeding. (author)

  5. Planned upgrade to the coaxial plasma source facility for high heat flux plasma flows relevant to tokamak disruption simulations

    International Nuclear Information System (INIS)

    Caress, R.W.; Mayo, R.M.; Carter, T.A.

    1995-01-01

    Plasma disruptions in tokamaks remain serious obstacles to the demonstration of economical fusion power. In disruption simulation experiments, some important effects have not been taken into account. Present disruption simulation experimental data do not include effects of the high magnetic fields expected near the PFCs in a tokamak major disruption. In addition, temporal and spatial scales are much too short in present simulation devices to be of direct relevance to tokamak disruptions. To address some of these inadequacies, an experimental program is planned at North Carolina State University employing an upgrade to the Coaxial Plasma Source (CPS-1) magnetized coaxial plasma gun facility. The advantages of the CPS-1 plasma source over present disruption simulation devices include the ability to irradiate large material samples at extremely high areal energy densities, and the ability to perform these material studies in the presence of a high magnetic field. Other tokamak disruption relevant features of CPS-1U include a high ion temperature, high electron temperature, and long pulse length

  6. DAMAVAND - An Iranian tokamak with a highly elongated plasma cross-section

    International Nuclear Information System (INIS)

    Amrollahi, R.

    1997-01-01

    The ''DAMAVAND'' facility is an Iranian Tokamak with a highly elongated plasma cross-section and with a poloidal divertor. This Tokamak has the advantage to allow the plasma physics research under the conditions similar to those of ITER magnetic configuration. For example, the opportunity to reproduce partially the plasma disruptions without sacrificing the studies of: equilibrium, stability and control over the elongated plasma cross-section; processes in the near-wall plasma; auxiliary heating systems, etc. The range of plasma parameters, the configuration of ''DAMAVAND'' magnetic coils and passive loops, and their location within the vacuum chamber allow the creation of the plasma at the center of the vacuum chamber and the production of two poloidal volumes (upper and lower) for the divertor. (author)

  7. Josephson plasma resonance in vortex filament state of high temperature superconductors

    International Nuclear Information System (INIS)

    Matsuda, Yuji; Gaifullin, M.B.

    1996-01-01

    High temperature superconductors have the crystalline structure in which two-dimensional CuO 2 planes are piled in layers, consequently, the anisotropy of electroconductivity arises, and this brings about stable and low energy Josephson plasma in superconducting state. Also as to the vortex filament state of high temperature superconductors, the effect of thermal fluctuation due to low dimensionality, short coherence length and high transition temperature becomes conspicuous. In reality, these plasma and vortex filament state are related closely. Light reflection and plasma edge in superconducting state, Josephson plasma resonance in the vortex filament state of BiO 2 Sr 2 CaCu 2 O 8+δ , the plasma vibration in Josephson junction, Josephson plasma in magnetic field, Josephson plasma in the liquid state of vortex filament, Josephson plasma in the solid state of vortex filament, and Josephson plasma in parallel magnetic field are reported. The Josephson plasma resonance is the experimental means for exploring vortex filament state from microscopic standpoint, and its development hereafter is expected. (K.I.)

  8. X-ray spectroscopic study of high-temperature plasmas by curved crystal spectrometer

    International Nuclear Information System (INIS)

    Morita, Shigeru.

    1983-07-01

    Extensive studies have been carried out on the structure of X-ray spectra from the highly stripped ions of first transition elements and their behavior in high temperature plasma, using a high resolution crystal spectrometer. Calculation was made on the design and the use of a curved crystal spectrometer for plasma diagnostics. A Johann type crystal spectrometer for measuring X-ray lines was constructed on the basis of the calculation. The characteristics of curved crystals of LiF, Ge and quartz used for the measurement of Kα lines from first transition elements were investigated. Vacuum sparks have been formed for producing high temperature plasma which emits X-ray lines from highly stripped ions. Two different structures of vacuum spark plasma were shown, that is, thermalized point plasma and extended plasma associated with non-thermal electrons. The X-ray lines from the extended plasma, those associated with the K shell from the point plasma and the Kα lines of Ti through Zn from the point plasma have been observed. (Kako, I.)

  9. Clinical characteristics of high plasma adiponectin and high plasma leptin as risk factors for arterial stiffness and related end-organ damage.

    Science.gov (United States)

    Kohara, Katsuhiko; Ochi, Masayuki; Okada, Yoko; Yamashita, Taiji; Ohara, Maya; Kato, Takeaki; Nagai, Tokihisa; Tabara, Yasuharu; Igase, Michiya; Miki, Tetsuro

    2014-08-01

    The relationship between plasma levels of adiponectin and cardiovascular events is inconclusive. We evaluated the clinical characteristics of people with high plasma adiponectin and high plasma leptin levels. Thousand seven hundred participants recruited from visitors to the Anti-Aging Doc were divided into four groups by combining the bipartiles of plasma adiponectin and leptin levels in men and women separately: AL, high adiponectin and high leptin; Al, high adiponectin and low leptin; al, low adiponectin and low leptin; aL, low adiponectin and high leptin. Body composition, including visceral fat area and thigh muscle cross-sectional area (CSA), brachial-ankle pulse wave velocity (baPWV), periventricular hyperintensity, and urinary albumin excretion, were determined. Twenty percent of the studied population fell within the AL group. This group had a significantly higher visceral fat area than the Al group. Thigh muscle CSA was lowest in the AL group among groups. baPWV, brain white matter lesions, and albuminuria findings in the AL group were significantly higher than those of the Al group. Multiple and logistic regression analyses with confounding parameters further confirmed that plasma adiponectin was not an independent determinant for brain and renal small vessel-related disease. These findings suggest that the plasma level of adiponectin alone is not enough for the risk stratification of cardiovascular disease. Leptin resistance associated with skeletal muscle loss in addition to obesity may need to be addressed to identify high risk people with high plasma adiponectin levels. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. High-throughput fractionation of human plasma for fast enrichment of low- and high-abundance proteins.

    Science.gov (United States)

    Breen, Lucas; Cao, Lulu; Eom, Kirsten; Srajer Gajdosik, Martina; Camara, Lila; Giacometti, Jasminka; Dupuy, Damian E; Josic, Djuro

    2012-05-01

    Fast, cost-effective and reproducible isolation of IgM from plasma is invaluable to the study of IgM and subsequent understanding of the human immune system. Additionally, vast amounts of information regarding human physiology and disease can be derived from analysis of the low abundance proteome of the plasma. In this study, methods were optimized for both the high-throughput isolation of IgM from human plasma, and the high-throughput isolation and fractionation of low abundance plasma proteins. To optimize the chromatographic isolation of IgM from human plasma, many variables were examined including chromatography resin, mobile phases, and order of chromatographic separations. Purification of IgM was achieved most successfully through isolation of immunoglobulin from human plasma using Protein A chromatography with a specific resin followed by subsequent fractionation using QA strong anion exchange chromatography. Through these optimization experiments, an additional method was established to prepare plasma for analysis of low abundance proteins. This method involved chromatographic depletion of high-abundance plasma proteins and reduction of plasma proteome complexity through further chromatographic fractionation. Purification of IgM was achieved with high purity as confirmed by SDS-PAGE and IgM-specific immunoblot. Isolation and fractionation of low abundance protein was also performed successfully, as confirmed by SDS-PAGE and mass spectrometry analysis followed by label-free quantitative spectral analysis. The level of purity of the isolated IgM allows for further IgM-specific analysis of plasma samples. The developed fractionation scheme can be used for high throughput screening of human plasma in order to identify low and high abundance proteins as potential prognostic and diagnostic disease biomarkers.

  11. Radio-iodination of a rabbit fibrinogen by the chloramine-T method

    Energy Technology Data Exchange (ETDEWEB)

    Moza, A K; Kumar, M; Belavalgidad, M I; Sapru, R P [Post-Graduate Inst. of Medical Education and Research, Chandigarh (India). Dept. of Experimental Medicine

    1974-01-01

    A method for radio-iodination of fibrinogen using chloramine-T has been described. Samples of greater than 90% clottable counts were obtained. Electrophoretic mobility and immunodiffusion showed that the entire radioactivity was present in the fibrinogen band. In vivo studies on the turnover of this labelled product in rabbits showed a half-life of 52.8 to 61.7 hrs in two batches of animals. The results compare very well with the reported results obtained from fibrinogen labelled with radioactive iodine by the iodine-monochloride method. The advantages of the new method have been pointed out.

  12. Distribution of iodine-labelled fibrinogen in rat during endotoxin shock

    Energy Technology Data Exchange (ETDEWEB)

    Toth, J [Semmelweis Orvostudomanyi Egyetem, Budapest (Hungary); Spett, B; Bertok, L; Kocsar, L [Orszagos Frederic Joliot-Curie Sugarbiologiai es Sugaregeszsegugyi Kutato Intezet, Budapest (Hungary)

    1978-10-01

    Animals of the experimental and control groups received 10-10 microcurie i.v. /sup 125/I-fibrinogen. The fibrinogen forms a deposit on the surface of the microthrombi and we can find more activity where the thrombi were formed. 60 minutes after administering endotoxin the activity of the ilium of the shocked animals increased significantly (exceeding that of the control group by 37%). A considerable difference may be observed also 120 minutes later, and the activity of the liver amounts to twice the activity of control animals two hours after i.v. /sup 125/I-fibrinogen injection.

  13. Study of Dynamic Features of Surface Plasma in High-Power Disk Laser Welding

    International Nuclear Information System (INIS)

    Wang Teng; Gao Xiangdong; Seiji, Katayama; Jin, Xiaoli

    2012-01-01

    High-speed photography was used to obtain the dynamic changes in the surface plasma during a high-power disk laser welding process. A color space clustering algorithm to extract the edge information of the surface plasma region was developed in order to improve the accuracy of image processing. With a comparative analysis of the plasma features, i.e., area and height, and the characteristics of the welded seam, the relationship between the surface plasma and the stability of the laser welding process was characterized, which provides a basic understanding for the real-time monitoring of laser welding.

  14. High-power heating experiment of spherical tokamaks by use of plasma merging

    International Nuclear Information System (INIS)

    Ueda, Yoshinobu; Ono, Yasushi

    1999-01-01

    High-power heating of spherical tokamaks (STs) has been investigated experimentally by use of plasma merging effect. When two STs were coaxially collided, thermal energy of a colliding ST was injected into a target ST during short reconnection time (Alfven time). Though the thermal energy increment increased with decreasing plasma q value, thermal energy loss during the following relaxation, tended to be smaller with increasing q. The produced high-β STs had hallower current profiles and weaker paramagnetic toroidal field than those of single STs. Those heating properties indicate the plasma merging to be a promising initial heating method of ST plasmas. (author)

  15. Targets on the basis of ferrites and high-temperature superconductors for ion-plasma sputtering

    International Nuclear Information System (INIS)

    Lepeshev, A.A.; Saunin, V.N.; Telegin, S.V.; Polyakova, K.P.; Seredkin, V.A.; Pol'skij, A.I.

    2000-01-01

    Paper describes a method to produce targets for ion-plasma sputtering using plasma splaying of the appropriate powders on a cooled metal basis. Application of the plasma process was demonstrated to enable to produce complex shaped targets under the controlled atmosphere on the basis of ceramic materials ensuring their high composition homogeneity, as well as, reliable mechanical and thermal contact of the resultant coating with the base. One carried out experiments in ion-plasma sputtering of targets to prepare ferrite polycrystalline films to be used in magnetooptics and to prepare high-temperature superconductor epitaxial films [ru

  16. Achieving a long-lived high-beta plasma state by energetic beam injection

    Science.gov (United States)

    Guo, H. Y.; Binderbauer, M. W.; Tajima, T.; Milroy, R. D.; Steinhauer, L. C.; Yang, X.; Garate, E. G.; Gota, H.; Korepanov, S.; Necas, A.; Roche, T.; Smirnov, A.; Trask, E.

    2015-04-01

    Developing a stable plasma state with high-beta (ratio of plasma to magnetic pressures) is of critical importance for an economic magnetic fusion reactor. At the forefront of this endeavour is the field-reversed configuration. Here we demonstrate the kinetic stabilizing effect of fast ions on a disruptive magneto-hydrodynamic instability, known as a tilt mode, which poses a central obstacle to further field-reversed configuration development, by energetic beam injection. This technique, combined with the synergistic effect of active plasma boundary control, enables a fully stable ultra-high-beta (approaching 100%) plasma with a long lifetime.

  17. High fidelity kinetic modeling of magnetic reconnection in laboratory plasma

    Science.gov (United States)

    Stanier, A.; Daughton, W. S.

    2017-12-01

    Over the past decade, a great deal of progress has been made towards understanding the physics of magnetic reconnection in weakly collisional regimes of relevance to both fusion devices, and to space and astrophysical plasmas. However, there remain some outstanding unsolved problems in reconnection physics, such as the generation and influence of plasmoids (flux ropes) within reconnection layers, the development of magnetic turbulence, the role of current driven and streaming instabilities, and the influence of electron pressure anisotropy on the layer structure. Due to the importance of these questions, new laboratory reconnection experiments are being built to allow controlled and reproducible study of such questions with the simultaneous acquisition of high time resolution measurements at a large number of spatial points. These experiments include the FLARE facility at Princeton University and the T-REX experiment at the University of Wisconsin. To guide and interpret these new experiments, and to extrapolate the results to space applications, new investments in kinetic modeling tools are required. We have recently developed a cylindrical version of the VPIC Particle-In-Cell code with the capability to perform first-principles kinetic simulations that approach experimental device size with more realistic geometry and drive coils. This cylindrical version inherits much of the optimization work that has been done recently for the next generation many-cores architectures with wider vector registers, and achieves comparable conservation properties as the Cartesian code. Namely it features exact discrete charge conservation, and a so-called "energy-conserving" scheme where the energy is conserved in the limit of continuous time, i.e. without contribution from spatial discretization (Lewis, 1970). We will present initial results of modeling magnetic reconnection in the experiments mentioned above. Since the VPIC code is open source (https

  18. Simulative research on the expansion of cathode plasma in high-current electron beam diode

    International Nuclear Information System (INIS)

    Xu Qifu; Liu Lie

    2012-01-01

    The expansion of cathode plasma has long been recognized as a limiting factor in the impedance lifetime of high-current electron beam diode. Realistic modeling of such plasma is of great necessity in order to discuss the dynamics of cathode plasma. Using the method of particle-in-cell, the expansion of cathode plasma is simulated in this paper by a scaled-down diode model. It is found that the formation of cathode plasma increases the current density in the diode. This consequently leads to the decrease of the potential at plasma front. Once the current density has been increased to a certain value, the potential at plasma front would then be equal to or lower than the plasma potential. Then the ions would move towards the anode, and the expansion of cathode plasma is thereby formed. Different factors affecting the plasma expansion velocity are discussed in this paper. It is shown that the decrease of proton genatation rate has the benefit of reducing the plasma expansion velocity.

  19. Formation and termination of High ion temperature mode in Heliotron/torsatron plasmas

    International Nuclear Information System (INIS)

    Ida, K.; Kondo, K.; Nagasaki, K.

    1997-01-01

    Physics of the formation and termination of High ion temperature mode (high T i mode) are studied by controlling density profiles and radial electric field. High ion temperature mode is observed for neutral beam heated plasmas in Heliotron/torsatron plasmas (Heliotron-E). This high T i mode plasma is characterized by a peaked ion temperature profile and is associated with a peaked electron density profile produced by neutral beam fueling with low wall recycling. This high T i mode is terminated by flattening the electron density caused by either gas puffing or second harmonic ECH (core density 'pump-out'). (author)

  20. Highly Resolved Measurements of a Developing Strong Collisional Plasma Shock

    Science.gov (United States)

    Rinderknecht, Hans G.; Park, H.-S.; Ross, J. S.; Amendt, P. A.; Higginson, D. P.; Wilks, S. C.; Haberberger, D.; Katz, J.; Froula, D. H.; Hoffman, N. M.; Kagan, G.; Keenan, B. D.; Vold, E. L.

    2018-03-01

    The structure of a strong collisional shock front forming in a plasma is directly probed for the first time in laser-driven gas-jet experiments. Thomson scattering of a 526.5 nm probe beam was used to diagnose temperature and ion velocity distribution in a strong shock (M ˜11 ) propagating through a low-density (ρ ˜0.01 mg /cc ) plasma composed of hydrogen. A forward-streaming population of ions traveling in excess of the shock velocity was observed to heat and slow down on an unmoving, unshocked population of cold protons, until ultimately the populations merge and begin to thermalize. Instabilities are observed during the merging, indicating a uniquely plasma-phase process in shock front formation.

  1. Experimental high power plasma-filled backward wave oscillator results

    International Nuclear Information System (INIS)

    Minami, K.; Lou, W.R.; Destler, W.W.; Kehs, R.A.; Granatstein, V.L.; Carmel, Y.

    1988-01-01

    Previous results have indicated that a background gas can be used to increase the output microwave power of relativistic backward wave oscillators (BWOs) two or three times the vacuum case. In their experiments, two methods of plasma production are investigated in detail: the use of the electron beam to ionize a background gas, and the use of a plasma gun to inject a background plasma into the slow-wave structure of a BWO. It is found in the first case that there was a resonant increase in microwave power at a particular pressure of the background gas by a factor of ten. In the second case, power also increased compared with power production in vacuum. Detailed results are presented and the relative merits of the two approaches is discussed and compared with theoretical expectations

  2. High energy ions and energetic plasma irradiation effects on aluminum in a Filippov-type plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Roshan, M.V. [National Institute of Education, Nanyang Technological University, 1 Nanyang Walk, Singapore 637616 (Singapore)], E-mail: mroshan20@yahoo.com; Rawat, R.S. [National Institute of Education, Nanyang Technological University, 1 Nanyang Walk, Singapore 637616 (Singapore); Babazadeh, A.R.; Emami, M.; Sadat Kiai, S.M. [Plasma Physics Research Center, AEOI, 14155-1339 Tehran (Iran, Islamic Republic of); Verma, R.; Lin, J.J.; Talebitaher, A.R.; Lee, P.; Springham, S.V. [National Institute of Education, Nanyang Technological University, 1 Nanyang Walk, Singapore 637616 (Singapore)

    2008-12-30

    High energy ions and energetic plasma irradiation of aluminum cathode inserts have been accomplished in nitrogen and argon filled plasma focus device. The Filippov-type plasma focus facility, Dena, with 288 {mu}F capacitor bank and charging voltage of 25 kV (90 kJ maximum storage energy) was first optimized for strong ion beam generation for nitrogen and argon gases by maximizing hard X-ray emission efficiency. X-ray diffraction analysis as well as scanning electron microscopy along with energy dispersive X-ray spectroscopy carried out to study the structural, morphological and compositional profile of the treated samples. Change in preferred orientation, emergence of meta-stable phases, generation of copper micro-droplets, and production of cracks across the sample are demonstrated and discussed. The micro-hardness measurements in Vickers scale reveal that after ion irradiation, the surface hardness of samples is reduced.

  3. Development of a laser-induced plasma probe to measure gas phase plasma signals at high pressures and temperatures

    International Nuclear Information System (INIS)

    Gounder, J.D.; Kutne, P.; Meier, W.

    2012-01-01

    The ability of laser induced breakdown spectroscopy (LIBS) technique for on line simultaneous measurement of elemental concentrations has led to its application in a wide number of processes. The simplicity of the technique allows its application to harsh environments such as present in boilers, furnaces and gasifiers. This paper presents the design of a probe using a custom optic which transforms a round beam into a ring (Donut) beam, which is used for forming a plasma in an atmosphere of nitrogen at high pressure (20 bar) and temperature (200 °C). The LIBS experiments were performed using a high pressure cell to characterize and test the effectiveness of the donut beam transmitted through the LIBS probe and collect plasma signal in back scatter mode. The first tests used the second harmonic of a Nd:YAG laser, pulse width 7 ns, to form a plasma in nitrogen gas at five different pressures (1, 5, 10, 15 and 20 bar) and three different gas temperatures (25, 100 and 200 °C). The uniqueness of this probe is the custom made optic used for reshaping the round laser beam into a ring (Donut) shaped laser beam, which is fed into the probe and focused to form a plasma at the measurement point. The plasma signal is collected and collimated using the laser focusing lens and is reflected from the laser beam axis onto an achromatic lens by a high reflection mirror mounted in the center section of the donut laser beam. The effect of gas pressure and temperature on N(I) lines in the high pressure cell experiment shows that the line intensity decreases with pressure and increases with temperature. Mean plasma temperature was calculated using the ratios of N(I) line intensities ranging from 7400 K to 8900 K at 1 bar and 2400 K to 3200 K at 20 bar for the three different gas temperatures. The results show that as a proof of principle the donut beam optics in combination with the LIBS probe can be used for performing extensive LIBS measurements in well controlled laboratory

  4. Development of a laser-induced plasma probe to measure gas phase plasma signals at high pressures and temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Gounder, J.D., E-mail: James.Gounder@dlr.de; Kutne, P.; Meier, W.

    2012-08-15

    The ability of laser induced breakdown spectroscopy (LIBS) technique for on line simultaneous measurement of elemental concentrations has led to its application in a wide number of processes. The simplicity of the technique allows its application to harsh environments such as present in boilers, furnaces and gasifiers. This paper presents the design of a probe using a custom optic which transforms a round beam into a ring (Donut) beam, which is used for forming a plasma in an atmosphere of nitrogen at high pressure (20 bar) and temperature (200 Degree-Sign C). The LIBS experiments were performed using a high pressure cell to characterize and test the effectiveness of the donut beam transmitted through the LIBS probe and collect plasma signal in back scatter mode. The first tests used the second harmonic of a Nd:YAG laser, pulse width 7 ns, to form a plasma in nitrogen gas at five different pressures (1, 5, 10, 15 and 20 bar) and three different gas temperatures (25, 100 and 200 Degree-Sign C). The uniqueness of this probe is the custom made optic used for reshaping the round laser beam into a ring (Donut) shaped laser beam, which is fed into the probe and focused to form a plasma at the measurement point. The plasma signal is collected and collimated using the laser focusing lens and is reflected from the laser beam axis onto an achromatic lens by a high reflection mirror mounted in the center section of the donut laser beam. The effect of gas pressure and temperature on N(I) lines in the high pressure cell experiment shows that the line intensity decreases with pressure and increases with temperature. Mean plasma temperature was calculated using the ratios of N(I) line intensities ranging from 7400 K to 8900 K at 1 bar and 2400 K to 3200 K at 20 bar for the three different gas temperatures. The results show that as a proof of principle the donut beam optics in combination with the LIBS probe can be used for performing extensive LIBS measurements in well controlled

  5. Ion production and bipolar fluxes in a high-current plasma-filled diode

    International Nuclear Information System (INIS)

    Ivanenkov, G.V.

    1982-01-01

    The model and the evolution of behaviour of binary layers (BL) in expanding plasma of high current plasma-filled diode are described. The model estimates ion current and the laws of plasma expansion at the stage of BL intensive growth. The density range (10 12 -10 15 cm -3 ) is determined in which diode impedance growth takes place in connection with BL appearance. The density of ion current at the outlet of diode is 10 A/cm 2

  6. Determination of boldine in plasma by high-performance liquid chromatography.

    Science.gov (United States)

    Speisky, H; Cassels, B K; Nieto, S; Valenzuela, A; Nuñez-Vergara, L J

    1993-02-26

    A sensitive method for the determination of boldine in blood plasma is described. The procedure involves a direct pH-buffered chloroform extraction of boldine from blood plasma, followed by its assay under isocratic conditions by HPLC with UV detection. The extraction recovery is excellent, and sensitivity and precision of the method are very high, when applied to plasma samples containing pharmacologically relevant concentrations of boldine.

  7. Absolute decay parametric instability of high-temperature plasma

    International Nuclear Information System (INIS)

    Zozulya, A.A.; Silin, V.P.; Tikhonchuk, V.T.

    1986-01-01

    A new absolute decay parametric instability having wide spatial localization region is shown to be possible near critical plasma density. Its excitation is conditioned by distributed feedback of counter-running Langmuir waves occurring during parametric decay of incident and reflected pumping wave components. In a hot plasma with the temperature of the order of kiloelectronvolt its threshold is lower than that of a known convective decay parametric instability. Minimum absolute instability threshold is shown to be realized under conditions of spatial parametric resonance of higher orders

  8. Electromagnetically induced transparency in high-temperature magnetoactive plasma

    International Nuclear Information System (INIS)

    Kryachko, A.Yu.; Litvak, A.G.; Tokman, M.D.

    2002-01-01

    The classical analog of the presently popular in the quantum electronics effect of the electromagnetically induced transparency (EIT) is studied. The EIT effect is considered for the electron-cyclotron waves in the plasma with the finite temperature. The expression for the effective index of the electromagnetic wave refraction is identified and the dispersion law and this wave absorption under the EIT conditions are studied. It is shown, that accounting for the thermal motion, which radically changes the behavior of the signal wave dispersion curves in the EIT area, as compared with the cold plasma case [ru

  9. High-frequency microinstabilities in hot-electron plasmas

    International Nuclear Information System (INIS)

    Chen, Y.J.; Nevins, W.M.; Smith, G.R.

    1981-01-01

    Instabilities with frequencies in the neighborhood of the electron cyclotron frequency are of interest in determining stable operating regimes of hot-electron plasmas in EBT devices and in tandem mirrors. Previous work used model distributions significantly different than those suggested by recent Fokker-Planck studies. We use much more realistic model distributions in a computer code that solves the full electromagnetic dispersion relation governing longitudinal and transverse waves in a uniform plasma. We allow for an arbitrary direction of wave propagation. Results for the whistler and upper-hybrid loss-cone instabilities are presented

  10. Transport analysis of high radiation and high density plasmas in the ASDEX Upgrade tokamak

    Directory of Open Access Journals (Sweden)

    Casali L.

    2014-01-01

    Full Text Available Future fusion reactors, foreseen in the “European road map” such as DEMO, will operate under more demanding conditions compared to present devices. They will require high divertor and core radiation by impurity seeding to reduce heat loads on divertor target plates. In addition, DEMO will have to work at high core densities to reach adequate fusion performance. The performance of fusion reactors depends on three essential parameters: temperature, density and energy confinement time. The latter characterizes the loss rate due to both radiation and transport processes. The DEMO foreseen scenarios described above were not investigated so far, but are now addressed at the ASDEX Upgrade tokamak. In this work we present the transport analysis of such scenarios. Plasma with high radiation by impurity seeding: transport analysis taking into account the radiation distribution shows no change in transport during impurity seeding. The observed confinement improvement is an effect of higher pedestal temperatures which extend to the core via stiffness. A non coronal radiation model was developed and compared to the bolometric measurements in order to provide a reliable radiation profile for transport calculations. High density plasmas with pellets: the analysis of kinetic profiles reveals a transient phase at the start of the pellet fuelling due to a slower density build up compared to the temperature decrease. The low particle diffusion can explain the confinement behaviour.

  11. Zeolite Nanoparticles for Selective Sorption of Plasma Proteins.

    Science.gov (United States)

    Rahimi, M; Ng, E-P; Bakhtiari, K; Vinciguerra, M; Ali Ahmad, H; Awala, H; Mintova, S; Daghighi, M; Bakhshandeh Rostami, F; de Vries, M; Motazacker, M M; Peppelenbosch, M P; Mahmoudi, M; Rezaee, F

    2015-11-30

    The affinity of zeolite nanoparticles (diameter of 8-12 nm) possessing high surface area and high pore volume towards human plasma proteins has been investigated. The protein composition (corona) of zeolite nanoparticles has been shown to be more dependent on the plasma protein concentrations and the type of zeolites than zeolite nanoparticles concentration. The number of proteins present in the corona of zeolite nanoparticles at 100% plasma (in vivo state) is less than with 10% plasma exposure. This could be due to a competition between the proteins to occupy the corona of the zeolite nanoparticles. Moreover, a high selective adsorption for apolipoprotein C-III (APOC-III) and fibrinogen on the zeolite nanoparticles at high plasma concentration (100%) was observed. While the zeolite nanoparticles exposed to low plasma concentration (10%) exhibited a high selective adsorption for immunoglobulin gamma (i.e. IGHG1, IGHG2 and IGHG4) proteins. The zeolite nanoparticles can potentially be used for selectively capture of APOC-III in order to reduce the activation of lipoprotein lipase inhibition during hypertriglyceridemia treatment. The zeolite nanoparticles can be adapted to hemophilic patients (hemophilia A (F-VIII deficient) and hemophilia B (F-IX deficient)) with a risk of bleeding, and thus might be potentially used in combination with the existing therapy.

  12. Non-equilibrium plasma chemistry at high pressure and its applications

    International Nuclear Information System (INIS)

    Bai Xiyao; Zhang Zhitao; Bai Mindong; Zhu Qiaoying

    2000-01-01

    A review is presented of research and development of gas discharge and non-equilibrium plasma including, new ideas of non-equilibrium plasma at high gas pressure. With special technology, strong electric fields (>400 Td) can be achieved by which electrons are accelerated suddenly, becoming high energy electrons (> 10 eV) at high pressure. On impact with the electrons, the gas molecules dissociate into ions, atomic ions, atoms and free radicals, and new substances or molecules can be synthesized through custom design. Chemical reaction difficult to achieve by conventional method can be realized or accelerated. Non-equilibrium plasma chemistry at high pressure has wide application prospects

  13. Features of laser spectroscopy and diagnostics of plasma ions in high magnetic fields

    International Nuclear Information System (INIS)

    Semerok, A F; Fomichev, S V

    2003-01-01

    Laser induced fluorescence and laser absorption spectroscopies of plasma ions in high magnetic fields have been investigated. Both the high degree of Zeeman splitting of the resonant transitions and the ion rotational movement drastically change the properties of the resonance interaction of the continuous wave laser radiation with ions in highly magnetized plasma. Numerical solution of the density matrix equation for a dissipative two-level system with time-dependent detuning from resonance was used to analyse this interaction. A theoretical simulation was performed and compared with the experimental results obtained from the laser spectroscopy diagnostics of barium plasma ions in high magnetic fields in the several tesla range

  14. X radiation diagnostics of high-temperature laser plasma

    International Nuclear Information System (INIS)

    Marsak, Z.; Bryknar, Z.; Legova, S.; Pina, L.

    1980-01-01

    Main aspects of X-ray emission from plasma heated by a pulsed laser and methods of its detection are presented, especially using a pinhole camera and a multichannel spectrometer with p-i-n diodes and Be-filters for measurement in the energy range 0.5 keV to 3 keV. (author)

  15. Plasma turbulence imaging using high-power laser Thomson scattering

    Science.gov (United States)

    Zweben, S. J.; Caird, J.; Davis, W.; Johnson, D. W.; Le Blanc, B. P.

    2001-01-01

    The two-dimensional (2D) structure of plasma density turbulence in a magnetically confined plasma can potentially be measured using a Thomson scattering system made from components of the Nova laser of Lawrence Livermore National Laboratory. For a plasma such as the National Spherical Torus Experiment at the Princeton Plasma Physics Laboratory, the laser would form an ≈10-cm-wide plane sheet beam passing vertically through the chamber across the magnetic field. The scattered light would be imaged by a charge coupled device camera viewing along the direction of the magnetic field. The laser energy required to make 2D images of density turbulence is in the range 1-3 kJ, which can potentially be obtained from a set of frequency-doubled Nd:glass amplifiers with diameters in the range of 208-315 mm. A laser pulse width of ⩽100 ns would be short enough to capture the highest frequency components of the expected density fluctuations.

  16. Accurate methods for calculating atomic processes in high temperature plasmas

    International Nuclear Information System (INIS)

    Keady, J.J.; Abdallah, J.A. Jr.; Clark, R.E.H.

    1992-01-01

    A technique for computing monochromatic X-ray absorption is described and compared to experimental data. Calculations of power loss from carbon plasmas with comprehensive new datasets confirm that the direct inclusion of metastable states can noticeably decrease the calculated power loss

  17. Charge modes of pulsed high energy and high density plasma injection source

    International Nuclear Information System (INIS)

    Cheng, D.Y.

    1974-01-01

    Detonation (snowplow), deflagration and other modes of discharge can be produced in a single coaxial plasma gun. Conservation laws of mass, momentum and energy together with the entropy production condition of the discharge phenomena are used to identify dense discharge modes. The Rankine-Hugoniot relation for a magnetized plasma is derived. Discussions of how to design a deflagration plasma gun to yield a prescribed plasma kinetic energy and plasma beam density are given

  18. The β fibrinogen gene G-455A polymorphism in Asian subjects with ...

    African Journals Online (AJOL)

    Jonny Karunia Fajar

    2016-08-10

    Aug 10, 2016 ... Conclusions: In the Asian population, the b fibrinogen gene G-455A polymorphism was associ- ..... Kazakhstan, Kuwait, Kyrgyzstan, Laos, Lebanon, Malaysia, ... Thailand, Timor-Leste, Turkey, Turkmenistan, United Arab.

  19. Pitfalls of radioisotope diagnosis of deep venous thromboses with /sup 125/I-fibrinogen in traumatology

    Energy Technology Data Exchange (ETDEWEB)

    Novak, K.; Pestal, M. (Vyzkumny Ustav Traumatologicky, Brno (Czechoslovakia))

    1984-05-25

    Experience is described with the examination of deep venous thromboses of the lower extremities using /sup 125/I-fibrinogen. Intravenously administered labelled fibrinogen is taken up into the forming thrombus which may then be detected. Experience is presented with preparations of various makes. It was proved that in injured patients the biological half-life of /sup 125/I-fibrinogen is reduced to 50 hrs and less as against the standard half-life of 96.2 hrs. This is caused by fibrinogen losses owing to the injury, increased intensity of metabolic processes and the quality of the preparation being used. Injured patients should be examined using a highest quality preparation without denaturation damage to the labelled protein.

  20. Pitfalls of radioisotope diagnosis of deep venous thromboses with 125I-fibrinogen in traumatology

    International Nuclear Information System (INIS)

    Novak, K.; Pestal, M.

    1984-01-01

    Experience is described with the examination of deep venous thromboses of the lower extremities using 125 I-fibrinogen. Intravenously administered labelled fibrinogen is taken up into the forming thrombus which may then be detected. Experience is presented with preparations of various makes. It was proved that in injured patients the biological half-life of 125 I-fibrinogen is reduced to 50 hrs and less as against the standard half-life of 96.2 hrs. This is caused by fibrinogen losses owing to the injury, increased intensity of metabolic processes and the quality of the preparation being used. Injured patients should be examined using a highest quality preparation without denaturation damage to the labelled protein. (Ha)

  1. Development of suspension plasma sprayed alumina coatings with high enthalpy plasma torch

    Czech Academy of Sciences Publication Activity Database

    Tesař, Tomáš; Mušálek, Radek; Medřický, Jan; Kotlan, Jiří; Lukáč, František; Pala, Zdeněk; Ctibor, Pavel; Chráska, Tomáš; Houdková, Š.; Rimal, V.; Curry, N.

    2017-01-01

    Roč. 325, September (2017), s. 277-288 ISSN 0257-8972 R&D Projects: GA ČR GA15-12145S Institutional support: RVO:61389021 Keywords : Suspension plasma spraying * Aluminium oxide * Mechanical properties * Hardness * Adhesion * Wear resistance Subject RIV: JK - Corrosion ; Surface Treatment of Materials OBOR OECD: Coating and films Impact factor: 2.589, year: 2016 http://www.sciencedirect.com/science/article/pii/S0257897217306424

  2. Excitation of a plasma by high frequencies for illumination purposes

    International Nuclear Information System (INIS)

    Valdivia B, R.

    2003-01-01

    The power electronics plays a very important paper so much in the national as international industrial development. For that reason, many of the works are focused in the one analysis and amplification of this area with the purpose of finding improvements in the existent systems and always looking for oneself end: the energy saving. Moreover, in the last years has occurred great interest to other very important area given their properties of energy profit, novelty and mainly their wide range of applications. This area is the study and use of the plasma. Many institutions with international recognition already invest and they develop systems in these two big areas of the technology among those that is the National Institute of Nuclear Research (INlN) with some laboratories dedicated to the work of the plasma, one of them the Laboratory of Thermal Plasma Applications (LAPT). The conjugation of both areas was analysed and developed in the present work with the one purpose of designing a system to generate thermal plasma and to give him one or but applications like it is to produce a luminous source as like to degrade organic gases as the Methane or Acetylene. This was developed by means of a resonant inverter with the help of MOSFET IRFK2D450 transistors and a load L C in a serial-parallel configuration with the purpose to profit their condition of resonance to have the maximum transfer of energy to the plasma. For to have a best profit of the energy it was realized an analysis of design for to oblige to the transistors to commute in zero voltage (ZVS) and to avoid then lost of power of C A. (Author)

  3. Fibrinogen concentrate as a treatment for postpartum haemorrhage-induced coagulopathy: A study protocol for a randomised multicentre controlled trial. The fibrinogen in haemorrhage of DELivery (FIDEL) trial.

    Science.gov (United States)

    Ducloy-Bouthors, Anne-Sophie; Mignon, Alexandre; Huissoud, Cyril; Grouin, Jean-Marie; Mercier, Frédéric J

    2016-08-01

    Postpartum haemorrhage (PPH) remains the leading cause for maternal mortality worldwide. Hypofibrinogenaemia has been identified as a major risk factor for progress towards severe PPH. The efficacy of fibrinogen concentrate supplementation in PPH has been shown in various clinical settings but the level of evidence is not sufficient to prove the benefit, evaluate the risks, and determine the value, timing and dose of fibrinogen supplementation in PPH. The FIDEL trial objective is to evaluate the impact of a therapeutic strategy based on the early administration of human fibrinogen concentrate compared to the current practice based on late administration in severe PPH patients requiring second line uterotonics. This is a prospective multicentre, randomised, double-blind, placebo-controlled trial. A total of 412 patients will be randomised if they meet the following criteria: female patients≥18 years old, vaginal delivery, PPH requiring IV administration of prostaglandins (sulprostone) after 20 to 30minutes of oxytocin failure. The participants are assigned to receive either fibrinogen 3g or placebo infusions. The primary endpoint is a composite endpoint defined as the percentage of patients losing at least 4g/dL of Hb, and/or requiring a transfusion of at least 2 units of packed red blood cells, within the 48hours following fibrinogen administration. The purpose of this study is to demonstrate the efficacy and safety of an early fibrinogen concentrate infusion in uncontrolled active PPH. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  4. Two new planar coil designs for a high pressure radio frequency plasma source

    Science.gov (United States)

    Munsat, T.; Hooke, W. M.; Bozeman, S. P.; Washburn, S.

    1995-04-01

    Two planar coil designs for a high pressure rf plasma source are investigated using spectroscopic techniques and circuit analysis. In an Ar plasma a truncated version of the commonly used ``spiral'' coil is found to produce improvements in peak electron density of 20% over the full version. A coil with figure-8 geometry is found to move plasma inhomogeneities off of center and produce electron densities comparable to the spiral coils. Both of these characteristics are advantageous in industrial applications. Coil design characteristics for favorable power coupling are also determined, including the necessity of closed hydrodynamic plasma loops and the drawback of closely situated antiparallel coil currents.

  5. SCREENING OF HIGH-Z GRAINS AND RELATED PHENOMENA IN COLLOIDAL PLASMAS

    Directory of Open Access Journals (Sweden)

    O.Bystrenko

    2003-01-01

    Full Text Available Recent important results are briefly presented concerning the screening of high-Z impurities in colloidal plasmas. The review focuses on the phenomenon of nonlinear screening and its effects on the structure of colloidal plasmas, the role of trapped ions in grain screening, and the effects of strong collisions in the plasma background. It is shown that the above effects may strongly modify the properties of the grain screening giving rise to considerable deviations from the conventional Debye-Huckel theory as dependent on the physical processes in the plasma background.

  6. Emissions from heavy current carrying high density plasma and their diagnostics

    International Nuclear Information System (INIS)

    Hirano, Katsumi

    1987-06-01

    Workshop on ''Emissions from heavy current carrying high density plasma and diagnostics'' was held at Institute of Plasma Physics, Nagoya University on 3. and 4. December 1986 under a collaborating research Program. The workshop was attended by 43 researchers from 19 labolatories. A total of 22 papers were submitted and are presented in these proceedings. The largest group of papers was that on soft X-ray emission. It seems this topic is a foremost interest for groups which engaged in research of the Z pinch and the plasma focus. A variety of problems in pinched dense plasmas, namely spectroscopy, diagnostics, pinch dynamics, and related engineering aspects were also discussed. (author)

  7. Electron current generated in a toroidal plasma on injection of high-energy neutrals

    International Nuclear Information System (INIS)

    Kolesnichenko, Ya.I.; Reznik, S.N.

    1981-01-01

    Problem of generation of electron current in toroidal plasma with a high-energy ion beam produced during neutral injection has been considered. The analysis was performed on the assumption that plasma is in the regime of rare collisions (banana regime) and ion beam velocity is considerably lower than thermal velocity of plasma ions. Formulae establishing the relation between beam current and electron current have been derived. It follows from them that toroidal affect considerably plasma current generated with the beam and under certain conditions result in changing this current direction in an area remoted from magne-- tic axis [ru

  8. Deuterium-tritium TFTR plasmas in the high poloidal beta regime

    International Nuclear Information System (INIS)

    Sabbagh, S.A.; Mauel, M.E.; Navratil, G.A.

    1995-03-01

    Deuterium-tritium plasmas with enhanced energy confinement and stability have been produced in the high poloidal beta, advanced tokamak regime in TFTR. Confinement enhancement H triple-bond τ E /τ E ITER-89P > 4 has been obtained in a limiter H-mode configuration at moderate plasma current I p = 0.85 - 1.46 MA. By peaking the plasma current profile, β N dia triple-bond 10 8 tperpendicular > aB 0 /I p = 3 has been obtained in these plasma,s exceeding the β N limit for TFTR plasmas with lower internal inductance, l i . Fusion power exceeding 6.7 MW with a fusion power gain Q DT = 0.22 has been produced with reduced alpha particle first orbit loss provided by the increased l i

  9. Confinement properties of high energy density plasmas in the Wisconsin levitated octupole

    International Nuclear Information System (INIS)

    Twichell, J.C.

    1984-08-01

    The confinement of particles and energy is critically dependent on the plasma-wall interaction. Results of a study detailing this interaction are presented. High power ICRF heated and gun afterglow plasmas were studied to detail the mechanisms determining particle and energy confinement. An extensive zero-D simulation code is used to assist in interpreting the experimental data. Physically reasonable models for plasma surface interactions, time dependent coronal treatment of impurities and multiple region treatment of neutrals are used in modeling the plasma. Extensive diagnostic data are used to verify the model. Non-heated plasmas decay from 28 to 3 eV allowing clear identification of wall impact energy thresholds for desorption and particle reflection. The charge state distribution of impurities verifies the reflux to plasma diffusion rate ratio. Close agreement between the simulation and experimental data is found

  10. Simulation of ionization effects for high-density positron drivers in future plasma wakefield experiments

    International Nuclear Information System (INIS)

    Bruhwiler, D.L.; Dimitrov, D.A.; Cary, J.R.; Esarey, E.; Leemans, W.P.

    2003-01-01

    The plasma wakefield accelerator (PWFA) concept has been proposed as a potential energy doubler for present or future electron-positron colliders. Recent particle-in-cell (PIC) simulations have shown that the self-fields of the required electron beam driver can tunnel ionize neutral Li, leading to plasma wake dynamics differing significantly from that of a preionized plasma. It has also been shown, for the case of a preionized plasma, that the plasma wake of a positron driver differs strongly from that of an electron driver. We will present new PIC simulations, using the OOPIC code, showing the effects of tunneling ionization on the plasma wake generated by high-density positron drivers. The results will be compared to previous work on electron drivers with tunneling ionization and positron drivers without ionization. Parameters relevant to the energy doubler and the upcoming E-164x experiment at the Stanford Linear Accelerator Center will be considered

  11. Surface hardening induced by high flux plasma in tungsten revealed by nano-indentation

    Energy Technology Data Exchange (ETDEWEB)

    Terentyev, D., E-mail: dterenty@sckcen.be [SCK-CEN, Nuclear Materials Science Institute, Boeretang 200, 2400 Mol (Belgium); Bakaeva, A. [SCK-CEN, Nuclear Materials Science Institute, Boeretang 200, 2400 Mol (Belgium); Department of Applied Physics, Ghent University, St. Pietersnieuwstraat 41, 9000 Ghent (Belgium); Pardoen, T.; Favache, A. [Institute of Mechanics, Materials and Civil Engineering, Université catholique de Louvain, Place Sainte Barbe 2 L5.02.02, 1348 Louvain-la-Neuve (Belgium); Zhurkin, E.E. [Department of Experimental Nuclear Physics K-89, Faculty of Physics and Mechanics, St. Petersburg State Polytechnical University, 29 Polytekhnicheskaya str., 195251 St. Petersburg (Russian Federation)

    2016-08-01

    Surface hardness of tungsten after high flux deuterium plasma exposure has been characterized by nanoindentation. The effect of plasma exposure was rationalized on the basis of available theoretical models. Resistance to plastic penetration is enhanced within the 100 nm sub-surface region, attributed to the pinning of geometrically necessary dislocations on nanometric deuterium cavities – signature of plasma-induced defects and deuterium retention. Sub-surface extension of thereby registered plasma-induced damage is in excellent agreement with the results of alternative measurements. The study demonstrates suitability of nano-indentation to probe the impact of deposition of plasma-induced defects in tungsten on near surface plasticity under ITER-relevant plasma exposure conditions.

  12. Contribution to the study of plasmatic fibrinogen and serum albumin: effects of irradiation

    International Nuclear Information System (INIS)

    Suscillon, M.

    1967-01-01

    The author studies the modifications of properties and structure of serum albumin and fibrinogen solution when subjected to radiation of low energy (X rays). On the other hand, two original techniques are exposed: 1. Amperometric determination of fibrin stabilizing factor or factor XIII of hemostasis. 2. Spectrophotometric study of fibrin formation kinetics. Then showing off and quantitative determination of platelets fibrinogen is exposed. (author) [fr

  13. Iodine-labelling of albumin and fibrinogen and application in selecting implantable material-titanium oxide

    International Nuclear Information System (INIS)

    Liu Fangyan; Zhou Meiying; Zhang Feng

    1998-01-01

    Human serum albumin and fibrinogen were successfully labelled with 125 I. The labelled proteins were further applied to carry out a background study on the selection of the blood-compatible materials. The protein adsorption of four kinds of titanium oxide film was determined and compared. It was found that Sample B can adsorb more albumin and less fibrinogen than other three samples and hold the adsorbed albumin most stably

  14. Potential formation and confinement in high density plasma on the GAMMA 10 tandem mirror

    International Nuclear Information System (INIS)

    Yatsu, K.

    2002-01-01

    After the attainment of doubling of the density due to the potential confinement, GAMMA 10 experiments have been directed to realization of a high density plasma and also to study dependence of the confining potential and confinement time on the plasma density. These problems are important to understand the physics of potential formation in tandem mirrors and also for the development of a tandem mirror reactor. We reported high density plasma production by using an ion cyclotron range of frequency heating at a high harmonic frequency in the last IAEA Conference. However, the diamagnetic signal of the high density plasma decreased when electron cyclotron resonance heating (ECRH) was applied due to some instabilities. Recently, the high density plasma production was much improved by adjusting the spacing of the conducting plates installed in the anchor transition regions, which enabled us to produce a high density plasma without degradation of the diamagnetic signal with ECRH and also to study the density dependence. In this paper we report production of a high density plasma and dependence of the confining potential and the confinement time on the density. (author)

  15. A rapid chemical method of labelling human plasma proteins with sup(99m)Tc-pertechnetate at pH 7.4

    International Nuclear Information System (INIS)

    Wong, D.W.; Mishkin, F.; Lee, T.

    1978-01-01

    A successful method for labelling human plasma proteins with sup(99m)Tc-pertechnetate by chemical means is described. The labelling methodology involves the production of Sup(99m)Tc-(Sn)citrate complex species with high protein binding capacity at pH 7.4 condition following initial chemical reduction of sodium sup(99m)Tc-pertechnetate by stannous chloride. A combined labelling efficiency range of 95-99% for sup(99m)Tc-labelled fibrinogen, immune gamma globulin and serum albumin is achieved. The actual amount of labelled protein content in the product is found to be 85-95% when assayed by ITLC and 74-85% by TCAA protein precipitation. In vitro experimental data indicate that sup(99m)Tc-fibrinogen contains an average of 85% clottable protein with an average clottability of 95%. This strongly suggests that the radioactive proteins retain much of their biological and physiological activities after the labelling process. (author)

  16. A high-performance channel engineered charge-plasma-based MOSFET with high-κ spacer

    Science.gov (United States)

    Shan, Chan; Wang, Ying; Luo, Xin; Bao, Meng-tian; Yu, Cheng-hao; Cao, Fei

    2017-12-01

    In this paper, the performance of graded channel double-gate MOSFET (GC-DGFET) that utilizes the charge-plasma concept and a high-κ spacer is investigated through 2-D device simulations. The results demonstrate that GC-DGFET with high-κ spacer can effectively improve the ON-state driving current (ION) and reduce the OFF-leakage current (IOFF). We find that reduction of the initial energy barrier between the source and channel is the origin of this ION enhancement. The reason for the IOFF reduction is identified to be the extension of the effective channel length owing to the fringing field via high-κ spacers. Consequently, these devices offer enhanced performance by reducing the total gate-to-gate capacitance (Cgg) and decreasing the intrinsic delay (τ).

  17. Linked tandem mirror configuration as a possible steady state high β plasma container

    International Nuclear Information System (INIS)

    Ikuta, Kazunari.

    1982-04-01

    A possibility of achieving steady state high β plasma confinement in toroidal geometry is considered in detail by closing off the ends of tandem mirrors entirely by flux bridges, where β is the ratio of plasma pressure to the magnetic pressure. The key problem of this approach seems to be the magnetic design of magneto-hydrodynamically stabilized, preferentially leaky bridges. (author)

  18. Modeling and experiments on differential pumping in linear plasma generators operating at high gas flows

    NARCIS (Netherlands)

    Eck, van H.J.N.; Koppers, W.R.; Rooij, van G.J.; Goedheer, W.J.; Engeln, R.A.H.; Schram, D.C.; Lopes Cardozo, N.J.; Kleyn, A.W.

    2009-01-01

    The direct simulation Monte Carlo (DSMC) method was used to investigate the efficiency of differential pumping in linear plasma generators operating at high gas flows. Skimmers are used to separate the neutrals from the plasma beam, which is guided from the source to the target by a strong axial

  19. Advanced Thomson scattering system for high-flux linear plasma generator

    NARCIS (Netherlands)

    Meiden, van der H.J.; Lof, A.R.; Berg, van den M.A.; Brons, S.; Donné, A.J.H.; Eck, van H.J.N.; Koelman, Peter; Koppers, W.R.; Kruijt, O.G.; Naumenko, N.N.; Oyevaar, T.; Prins, P.R.; Rapp, J.; Scholten, J.; Schram, D.C.; Smeets, P.H.M.; Star, van der G.; Tugarinov, S.N.; Zeijlmans van Emmichoven, P.A.

    2012-01-01

    An advanced Thomson scattering system has been built for a linear plasma generator for plasma surface interaction studies. The Thomson scattering system is based on a Nd:YAG laser operating at the second harmonic and a detection branch featuring a high etendue (f /3) transmission grating

  20. Deuterium-induced nanostructure formation on tungsten exposed to high-flux plasma

    NARCIS (Netherlands)

    Xu, H.Y.; De Temmerman, G.C.; Luo, G.-N.; Jia, Y.Z.; Yuan, Y.; Fu, B.Q.; Godfrey, A.; Liu, W.

    2015-01-01

    PLASMA-SURFACE INTERACTIONS 21 — Proceedings of the 21st International Conference on Plasma-Surface Interactions in Controlled Fusion Devices Kanazawa, Japan May 26-30, 2014 Surface topography of polycrystalline tungsten (W) have been examined after exposure to a low-energy (38 eV/D), high-flux