WorldWideScience

Sample records for high luminous sources

  1. Compact RGBY light sources with high luminance for laser display applications

    Science.gov (United States)

    Paschke, Katrin; Blume, Gunnar; Werner, Nils; Müller, André; Sumpf, Bernd; Pohl, Johannes; Feise, David; Ressel, Peter; Sahm, Alexander; Bege, Roland; Hofmann, Julian; Jedrzejczyk, Daniel; Tränkle, Günther

    2018-02-01

    Watt-class visible laser light with a high luminance can be created with high-power GaAs-based lasers either directly in the red spectral region or using single-pass second harmonic generation (SHG) for the colors in the blue-yellow spectral region. The concepts and results of red- and near infrared-emitting distributed Bragg reflector tapered lasers and master oscillator power amplifier systems as well as their application for SHG bench-top experiments and miniaturized modules are presented. Examples of these high-luminance light sources aiming at different applications such as flying spot display or holographic 3D cinema are discussed in more detail. The semiconductor material allows an easy adaptation of the wavelength allowing techniques such as six-primary color 3D projection or color space enhancement by adding a fourth yellow color.

  2. Observations of Ultra-Luminous X-ray Sources, and Implications

    Science.gov (United States)

    Colbert, E. J. M.

    2004-05-01

    I will review observations of Ultra-Luminous X-ray Sources (ULXs; Lx > 1E39 erg/s), in particular those observations that have helped reveal the nature of these curious objects. Some recent observations suggest that ULXs are a heterogenous class. Although ULX phenomenology is not fully understood, I will present some examples from the (possibly overlapping) sub-classes. Since ULXs are the most luminous objects in starburst galaxies, they, and ``normal'' luminous black-hole high-mass X-ray binaries are intimately tied to the global galaxian X-ray-star-formation connection. Further work is needed to understand how ULXs form, and how they are associated with the putative population of intermediate-mass black holes.

  3. The Highly Luminous Type Ibn Supernova ASASSN-14ms

    DEFF Research Database (Denmark)

    Vallely, P. J.; Prieto, J. L.; Stanek, K. Z.

    2018-01-01

    We present photometric and spectroscopic follow-up observations of the highly luminous Type Ibn supernova ASASSN-14ms, which was discovered on UT 2014-12-26.61 at $m_V \\sim 16.5$. With a peak absolute $V$-band magnitude brighter than $-20.5$, a peak bolometric luminosity of $1.7 \\times 10......^{44}$ ergs s$^{-1}$, and a total radiated energy of $2.1 \\times 10^{50}$ ergs, ASASSN-14ms is one of the most luminous Type Ibn supernovae yet discovered. In simple models, the most likely power source for this event is a combination of the radioactive decay of $^{56}$Ni and $^{56}$Co at late times...... and the interaction of supernova ejecta with the progenitor's circumstellar medium at early times, although we cannot rule out the possibility of a magnetar-powered light curve. The presence of a dense circumstellar medium is indicated by the intermediate-width He I features in the spectra. The faint ($m_g \\sim 21...

  4. Progress of OLED devices with high efficiency at high luminance

    Science.gov (United States)

    Nguyen, Carmen; Ingram, Grayson; Lu, Zhenghong

    2014-03-01

    Organic light emitting diodes (OLEDs) have progressed significantly over the last two decades. For years, OLEDs have been promoted as the next generation technology for flat panel displays and solid-state lighting due to their potential for high energy efficiency and dynamic range of colors. Although high efficiency can readily be obtained at low brightness levels, a significant decline at high brightness is commonly observed. In this report, we will review various strategies for achieving highly efficient phosphorescent OLED devices at high luminance. Specifically, we will provide details regarding the performance and general working principles behind each strategy. We will conclude by looking at how some of these strategies can be combined to produce high efficiency white OLEDs at high brightness.

  5. Astronomy. ASASSN-15lh: A highly super-luminous supernova.

    Science.gov (United States)

    Dong, Subo; Shappee, B J; Prieto, J L; Jha, S W; Stanek, K Z; Holoien, T W-S; Kochanek, C S; Thompson, T A; Morrell, N; Thompson, I B; Basu, U; Beacom, J F; Bersier, D; Brimacombe, J; Brown, J S; Bufano, F; Chen, Ping; Conseil, E; Danilet, A B; Falco, E; Grupe, D; Kiyota, S; Masi, G; Nicholls, B; Olivares E, F; Pignata, G; Pojmanski, G; Simonian, G V; Szczygiel, D M; Woźniak, P R

    2016-01-15

    We report the discovery of ASASSN-15lh (SN 2015L), which we interpret as the most luminous supernova yet found. At redshift z = 0.2326, ASASSN-15lh reached an absolute magnitude of Mu ,AB = -23.5 ± 0.1 and bolometric luminosity Lbol = (2.2 ± 0.2) × 10(45) ergs s(-1), which is more than twice as luminous as any previously known supernova. It has several major features characteristic of the hydrogen-poor super-luminous supernovae (SLSNe-I), whose energy sources and progenitors are currently poorly understood. In contrast to most previously known SLSNe-I that reside in star-forming dwarf galaxies, ASASSN-15lh appears to be hosted by a luminous galaxy (MK ≈ -25.5) with little star formation. In the 4 months since first detection, ASASSN-15lh radiated (1.1 ± 0.2) × 10(52) ergs, challenging the magnetar model for its engine. Copyright © 2016, American Association for the Advancement of Science.

  6. Method and apparatus for generating highly luminous flame

    Energy Technology Data Exchange (ETDEWEB)

    Gitman, G.M.

    1992-05-12

    A combustion process and apparatus are provided for generating a variable high temperature, highly luminous flame with low NOx emission by burning gaseous and liquid materials with oxygen and air. More particularly, the invention provides a process in which there is initial control of fuel, oxygen, and air flows and the delivery of the oxidizers to a burner as two oxidizing gases having different oxygen concentrations (for example, pure oxygen and air, or oxygen and oxygen-enriched air). A first oxidizing gas containing a high oxygen concentration is injected as a stream into the central zone of a combustion tunnel or chamber, and part of the fuel (preferably the major part) is injected into the central pyrolysis zone to mix with the first oxidizing gas to create a highly luminous high-temperature flame core containing microparticles of carbon of the proper size for maximum luminosity and high temperature, and a relatively small amount of hydrocarbon radicals. In addition, part of the fuel (preferably the minor part) is injected in a plurality of streams about the flame core to mix with a second oxidizing gas (containing a lower oxygen concentration than the first oxidizing gas) and injecting the second oxidizing mixture about the flame core and the minor fuel flow to mix with the minor fuel flow. This creates a plurality of fuel-lean (oxygen-rich) flames which are directed toward the luminous flame core to form a final flame pattern having high temperature, high luminosity, and low NOx content. 6 figs.

  7. Classification of radioactive self-luminous light sources - approved 1975. NBS Handbook 116

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The standard establishes the classification of certain radioactive self-luminous light sources according to radionuclide, type of source, activity, and performance requirements. The objectives are to establish minimum prototype testing requirements for radioactive self-luminous light sources, to promote uniformity of marking such sources, and to establish minimum physical performance for such sources. The standard is primarily directed toward assuring adequate containment of the radioactive material. Testing procedures and classification designations are specified for discoloration, temperature, thermal shock, reduced pressure, impact, vibration, and immersion. A range of test requirements is presented according to intended usage and source activity

  8. Contribution to the study of luminous sources for uranium isotope measurements by emission spectrometry

    International Nuclear Information System (INIS)

    Leichnam, J.P.; Capitini, R.

    1964-01-01

    After a brief summary of results obtained with different hollow cathode luminous sources, the reasons for which they cannot be more widely used are given: an insufficient luminosity when uranium oxides are used in the cathode hollow; the large amount of sample required when it is metallic; the impossibility of effecting a chemical purification of the sample. Electrode-less discharge tubes excited by high frequency whose qualities (luminosity, stability, rapidity of preparation starting from small amounts of sample in various chemical forms, in particular iron) satisfy the conditions laid down for the measurement of uranium 235 by interferometry are used. Tho production process for such lamps is given together with the method of excitation. Examples of recordings obtained with an interferometer of the 'HYPEAC' type and a small grating spectrometer give an idea of the spectral qualities of these sources. (authors) [fr

  9. Very Luminous X-ray Point Sources in Starburst Galaxies

    Science.gov (United States)

    Colbert, E.; Heckman, T.; Ptak, A.; Weaver, K. A.; Strickland, D.

    Extranuclear X-ray point sources in external galaxies with luminosities above 1039.0 erg/s are quite common in elliptical, disk and dwarf galaxies, with an average of ~ 0.5 and dwarf galaxies, with an average of ~0.5 sources per galaxy. These objects may be a new class of object, perhaps accreting intermediate-mass black holes, or beamed stellar mass black hole binaries. Starburst galaxies tend to have a larger number of these intermediate-luminosity X-ray objects (IXOs), as well as a large number of lower-luminosity (1037 - 1039 erg/s) point sources. These point sources dominate the total hard X-ray emission in starburst galaxies. We present a review of both types of objects and discuss possible schemes for their formation.

  10. The galactic luminous supersoft X-ray source RXJ0925.7-4758 / MR ...

    Indian Academy of Sciences (India)

    Nandita Prodhani

    2018-01-30

    Jan 30, 2018 ... White dwarf; luminous supersoft X-ray source; luminosity; absorption edge. PACS Nos 97.80.Jp; 97.10.Ri; 98.35.Mp; 97.80.Fk. 1. Introduction. For the last few decades, Einstein observatory, Roent- gen Satellite (ROSAT), ASCA, CHANDRA, XMM-. Newton, SWIFT, SUZAKU and other ingenious devices.

  11. Exploratory X-ray monitoring of luminous radio-quiet quasars at high redshift: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Shemmer, Ohad; Stein, Matthew S. [Department of Physics, University of North Texas, Denton, TX 76203 (United States); Brandt, W. N.; Schneider, Donald P. [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States); Paolillo, Maurizio [Dipartimento di Scienze Fisiche, Università Federico II di Napoli, via Cinthia 6, I-80126 Napoli (Italy); Kaspi, Shai [School of Physics and Astronomy and the Wise Observatory, Tel Aviv University, Tel Aviv 69978 (Israel); Vignali, Cristian [Dipartimento di Astronomia, Università degli studi di Bologna, via Ranzani 1, I-40127 Bologna (Italy); Lira, Paulina [Departamento de Astronomia, Universidad de Chile, Camino del Observatorio 1515, Santiago (Chile); Gibson, Robert R., E-mail: ohad@unt.edu [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States)

    2014-03-10

    We present initial results from an exploratory X-ray monitoring project of two groups of comparably luminous radio-quiet quasars (RQQs). The first consists of four sources at 4.10 ≤ z ≤ 4.35, monitored by Chandra, and the second is a comparison sample of three sources at 1.33 ≤ z ≤ 2.74, monitored by Swift. Together with archival X-ray data, the total rest-frame temporal baseline spans ∼2-4 yr and ∼5-13 yr for the first and second group, respectively. Six of these sources show significant X-ray variability over rest-frame timescales of ∼10{sup 2}-10{sup 3} days; three of these also show significant X-ray variability on rest-frame timescales of ∼1-10 days. The X-ray variability properties of our variable sources are similar to those exhibited by nearby and far less luminous active galactic nuclei (AGNs). While we do not directly detect a trend of increasing X-ray variability with redshift, we do confirm previous reports of luminous AGNs exhibiting X-ray variability above that expected from their luminosities, based on simplistic extrapolation from lower luminosity sources. This result may be attributed to luminous sources at the highest redshifts having relatively high accretion rates. Complementary UV-optical monitoring of our sources shows that variations in their optical-X-ray spectral energy distribution are dominated by the X-ray variations. We confirm previous reports of X-ray spectral variations in one of our sources, HS 1700+6416, but do not detect such variations in any of our other sources in spite of X-ray flux variations of up to a factor of ∼4. This project is designed to provide a basic assessment of the X-ray variability properties of RQQs at the highest accessible redshifts that will serve as a benchmark for more systematic monitoring of such sources with future X-ray missions.

  12. Observations of Intermediate-mass Black Holes and Ultra-Luminous X-ray sources

    Science.gov (United States)

    Colbert, E. J. M.

    2003-12-01

    I will review various observations that suggest that intermediate-mass black holes (IMBHs) with masses ˜102-104 M⊙ exist in our Universe. I will also discuss some of the limitations of these observations. HST Observations of excess dark mass in globular cluster cores suggest IMBHs may be responsible, and some mass estimates from lensing experiments are nearly in the IMBH range. The intriguing Ultra-Luminous X-ray sources (ULXs, or IXOs) are off-nuclear X-ray point sources with X-ray luminosities LX ≳ 1039 erg s-1. ULXs are typically rare (1 in every 5 galaxies), and the nature of their ultra-luminous emission is currently debated. I will discuss the evidence for IMBHs in some ULXs, and briefly outline some phenomenology. Finally, I will discuss future observations that can be made to search for IMBHs.

  13. Radio Observations of Ultra-Luminous X-Ray Sources and their Implication for Models

    Science.gov (United States)

    Koerding, E. G.; Colbert, E. J. M.; Falcke, H.

    2004-05-01

    We present the results of a radio monitoring campaign to search for radio emission from nearby ultra-luminous X-ray sources (ULXs). These intriguing sources are bright off-nuclear X-ray point sources with luminosities exceeding LX > 1039 erg/sec. Assuming isotropic emission the Eddington Limit suggests that they harbor intermediate mass black holes. Due to the problems of this explanation also other possibilities are currently discussed, among them are anisotropic emission, super-Eddington accretion flows or relativistically beamed emission from microquasars. Detections of compact radio cores at the positions of ULXs would be a direct hint to jet-emission. However, as the ULX phenomenom is connected to star formation we have to assume that they are strongly accreting objects. Thus, similar to their nearest Galactic cousins, the very high state X-ray binaries (see e.g., GRS 1915), ULXs may show radio flares. A well-defined sample of the 9 nearest ULXs has been monitored eight times during 5 months with the Very Large Array in A and B configuration. Our limiting sensitivity is 0.15 mJy (4 σ ) for flares and 68 μ Jy for continuous emission. In M82 some ULXs seem to be connected to radio supernova remnants. Besides that no flare or continuous emission has been detected. As the timescales of radio flares in ULXs are highly uncertain, it could well be that we have undersampled the lightcurve. However, upper bounds for the probability to detect a flare can be given. The upper limits for the continuous emission are compared with the emission found in NGC 5408 X-1 and with quasars and microquasars. We show that these limits are well in agreement with the microblazar model using the Radio/X-ray correlation of XRBs and AGN. Thus, it could well be that ULXs are microblazers which may be radio loud.

  14. PATCHY ACCRETION DISKS IN ULTRA-LUMINOUS X-RAY SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Miller, J. M. [Department of Astronomy, University of Michigan, 500 Church Street, Ann Arbor, MI 48109-1042 (United States); Bachetti, M.; Barret, D.; Webb, N. A. [Universite de Toulouse, UPS-OMP, IRAP, F- 31100 Toulouse (France); Harrison, F. A.; Walton, D. J.; Rana, V. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Fabian, A. C., E-mail: jonmm@umich.edu [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom)

    2014-04-10

    The X-ray spectra of the most extreme ultra-luminous X-ray sources—those with L ≥ 10{sup 40} erg s{sup –1}—remain something of a mystery. Spectral roll-over in the 5-10 keV band was originally detected in the deepest XMM-Newton observations of the brightest sources; this is confirmed in subsequent NuSTAR spectra. This emission can be modeled via Comptonization, but with low electron temperatures (kT{sub e} ≅ 2 keV) and high optical depths (τ ≅ 10) that pose numerous difficulties. Moreover, evidence of cooler thermal emission that can be fit with thin disk models persists, even in fits to joint XMM-Newton and NuSTAR observations. Using NGC 1313 X-1 as a test case, we show that a patchy disk with a multiple temperature profile may provide an excellent description of such spectra. In principle, a number of patches within a cool disk might emit over a range of temperatures, but the data only require a two-temperature profile plus standard Comptonization, or three distinct blackbody components. A mechanism such as the photon bubble instability may naturally give rise to a patchy disk profile, and could give rise to super-Eddington luminosities. It is possible, then, that a patchy disk (rather than a disk with a standard single-temperature profile) might be a hallmark of accretion disks close to or above the Eddington limit. We discuss further tests of this picture and potential implications for sources such as narrow-line Seyfert-1 galaxies and other low-mass active galactic nuclei.

  15. SPITZER IRS SPECTRA OF LUMINOUS 8 μm SOURCES IN THE LARGE MAGELLANIC CLOUD: TESTING COLOR-BASED CLASSIFICATIONS

    International Nuclear Information System (INIS)

    Buchanan, Catherine L.; Kastner, Joel H.; Hrivnak, Bruce J.; Sahai, Raghvendra

    2009-01-01

    We present archival Spitzer Infrared Spectrograph (IRS) spectra of 19 luminous 8 μm selected sources in the Large Magellanic Cloud (LMC). The object classes derived from these spectra and from an additional 24 spectra in the literature are compared with classifications based on Two Micron All Sky Survey (2MASS)/MSX (J, H, K, and 8 μm) colors in order to test the 'JHK8' (Kastner et al.) classification scheme. The IRS spectra confirm the classifications of 22 of the 31 sources that can be classified under the JHK8 system. The spectroscopic classification of 12 objects that were unclassifiable in the JHK8 scheme allow us to characterize regions of the color-color diagrams that previously lacked spectroscopic verification, enabling refinements to the JHK8 classification system. The results of these new classifications are consistent with previous results concerning the identification of the most infrared-luminous objects in the LMC. In particular, while the IRS spectra reveal several new examples of asymptotic giant branch (AGB) stars with O-rich envelopes, such objects are still far outnumbered by carbon stars (C-rich AGB stars). We show that Spitzer IRAC/MIPS color-color diagrams provide improved discrimination between red supergiants and oxygen-rich and carbon-rich AGB stars relative to those based on 2MASS/MSX colors. These diagrams will enable the most luminous IR sources in Local Group galaxies to be classified with high confidence based on their Spitzer colors. Such characterizations of stellar populations will continue to be possible during Spitzer's warm mission through the use of IRAC [3.6]-[4.5] and 2MASS colors.

  16. Total luminous flux measurement for flexible surface sources with an integrating sphere photometer

    International Nuclear Information System (INIS)

    Yu, Hsueh-Ling; Liu, Wen-Chun

    2014-01-01

    Applying an integrating sphere photometer for total luminous flux measurement is a widely used method. However, the measurement accuracy depends on the spatial uniformity of the integrating sphere, especially when the test sample has a different light distribution from that of the standard source. Therefore, spatial correction is needed to eliminate the effect caused by non-uniformity. To reduce the inconvenience of spatial correction but retain the measurement accuracy, a new type of working standard is designed for flexible and curved surface sources. Applying this new type standard source, the measurement deviation due to different orientations is reduced by an order of magnitude compared with using a naked incandescent lamp as the standard source. (paper)

  17. Measuring high-resolution sky luminance distributions with a CCD camera.

    Science.gov (United States)

    Tohsing, Korntip; Schrempf, Michael; Riechelmann, Stefan; Schilke, Holger; Seckmeyer, Gunther

    2013-03-10

    We describe how sky luminance can be derived from a newly developed hemispherical sky imager (HSI) system. The system contains a commercial compact charge coupled device (CCD) camera equipped with a fish-eye lens. The projection of the camera system has been found to be nearly equidistant. The luminance from the high dynamic range images has been calculated and then validated with luminance data measured by a CCD array spectroradiometer. The deviation between both datasets is less than 10% for cloudless and completely overcast skies, and differs by no more than 20% for all sky conditions. The global illuminance derived from the HSI pictures deviates by less than 5% and 20% under cloudless and cloudy skies for solar zenith angles less than 80°, respectively. This system is therefore capable of measuring sky luminance with the high spatial and temporal resolution of more than a million pixels and every 20 s respectively.

  18. Nonlinear mapping of the luminance in dual-layer high dynamic range displays

    Science.gov (United States)

    Guarnieri, Gabriele; Ramponi, Giovanni; Bonfiglio, Silvio; Albani, Luigi

    2009-02-01

    It has long been known that the human visual system (HVS) has a nonlinear response to luminance. This nonlinearity can be quantified using the concept of just noticeable difference (JND), which represents the minimum amplitude of a specified test pattern an average observer can discern from a uniform background. The JND depends on the background luminance following a threshold versus intensity (TVI) function. It is possible to define a curve which maps physical luminances into a perceptually linearized domain. This mapping can be used to optimize a digital encoding, by minimizing the visibility of quantization noise. It is also commonly used in medical applications to display images adapting to the characteristics of the display device. High dynamic range (HDR) displays, which are beginning to appear on the market, can display luminance levels outside the range in which most standard mapping curves are defined. In particular, dual-layer LCD displays are able to extend the gamut of luminance offered by conventional liquid crystals towards the black region; in such areas suitable and HVS-compliant luminance transformations need to be determined. In this paper we propose a method, which is primarily targeted to the extension of the DICOM curve used in medical imaging, but also has a more general application. The method can be modified in order to compensate for the ambient light, which can be significantly greater than the black level of an HDR display and consequently reduce the visibility of the details in dark areas.

  19. Green Fluorescent Organic Light Emitting Device with High Luminance

    Directory of Open Access Journals (Sweden)

    Ning YANG

    2014-06-01

    Full Text Available In this work, we fabricated the small molecule green fluorescent bottom-emission organic light emitting device (OLED with the configuration of glass substrate/indium tin oxide (ITO/Copper Phthalocyanine (CuPc 25 nm/ N,N’-di(naphthalen-1-yl-N,N’-diphenyl-benzidine (NPB 45 nm/ tris(8-hydroxyquinoline aluminium (Alq3 60 nm/ Lithium fluoride (LiF 1 nm/Aluminum (Al 100 nm where CuPc and NPB are the hole injection layer and the hole transport layer, respectively. CuPc is introduced in this device to improve carrier injection and efficiency. The experimental results indicated that the turn-on voltage is 2.8 V with a maximum luminance of 23510 cd/m2 at 12 V. The maximum current efficiency and power efficiency are 4.8 cd/A at 100 cd/m2 and 4.2 lm/W at 3 V, respectively. The peak of electroluminance (EL spectrum locates at 530 nm which is typical emission peak of green light. In contrast, the maximum current efficiency and power efficiency of the device without CuPc are only 4.0 cd/A at 100 mA/cm2 and 4.2 lm/W at 3.6 V, respectively.

  20. Ultra-luminous X-ray sources and intermediate-mass black holes

    International Nuclear Information System (INIS)

    Cseh, David

    2012-01-01

    More than ten years ago, the discovery of Ultra-luminous X-ray sources (ULXs) has opened up an entirely new field in astrophysics. Many ideas were developed to explain the nature of these sources, like their emission mechanism, mass, and origin, without any strong conclusions. Their discovery boosted the fields of X-ray binaries, accretion physics, stellar evolution, cosmology, black hole formation and growth, due to the concept of intermediate-mass black holes (IMBHs). Since their discovery is related to the domain of X-ray astrophysics, there have been very few studies made in other wavelengths. This thesis focuses on the multiwavelength nature of Ultra-luminous X-ray sources and intermediate-mass black holes from various aspects, which help to overcome some difficulties we face today. First, I investigated the accretion signatures of a putative intermediate-mass black hole in a particular globular cluster. To this purpose, I characterized the nature of the innermost X-ray sources in the cluster. Then I calculated an upper limit on the mass of the black hole by studying possible accretion efficiencies and rates based on the dedicated X-ray and radio observations. The accreting properties of the source was described with standard spherical accretion and in the context of inefficient accretion. Secondly, I attempted to dynamically measure the mass of the black hole in a particular ULX via optical spectroscopy. I discovered that a certain emission line has a broad component that markedly shifts in wavelength. I investigated the possibility whether this line originates in the accretion disk, and thus might trace the orbital motion of the binary system. I also characterized the parameters of the binary system, such as the mass function, possible orbital separation, the size of the line-emitting region, and an upper limit on the mass of the black hole. Then I studied the environment of a number of ULXs that are associated with large-scale optical and radio nebulae. I

  1. Visuoauditory mappings between high luminance and high pitch are shared by chimpanzees (Pan troglodytes) and humans

    Science.gov (United States)

    Ludwig, Vera U.; Adachi, Ikuma; Matsuzawa, Tetsuro

    2011-01-01

    Humans share implicit preferences for certain cross-sensory combinations; for example, they consistently associate higher-pitched sounds with lighter colors, smaller size, and spikier shapes. In the condition of synesthesia, people may experience such cross-modal correspondences to a perceptual degree (e.g., literally seeing sounds). So far, no study has addressed the question whether nonhuman animals share cross-modal correspondences as well. To establish the evolutionary origins of cross-modal mappings, we tested whether chimpanzees (Pan troglodytes) also associate higher pitch with higher luminance. Thirty-three humans and six chimpanzees were required to classify black and white squares according to their color while hearing irrelevant background sounds that were either high-pitched or low-pitched. Both species performed better when the background sound was congruent (high-pitched for white, low-pitched for black) than when it was incongruent (low-pitched for white, high-pitched for black). An inherent tendency to pair high pitch with high luminance hence evolved before the human lineage split from that of chimpanzees. Rather than being a culturally learned or a linguistic phenomenon, this mapping constitutes a basic feature of the primate sensory system. PMID:22143791

  2. High luminous flux from single crystal phosphor-converted laser-based white lighting system

    KAUST Repository

    Cantore, Michael

    2015-12-14

    The efficiency droop of light emitting diodes (LEDs) with increasing current density limits the amount of light emitted per wafer area. Since low current densities are required for high efficiency operation, many LED die are needed for high power white light illumination systems. In contrast, the carrier density of laser diodes (LDs) clamps at threshold, so the efficiency of LDs does not droop above threshold and high efficiencies can be achieved at very high current densities. The use of a high power blue GaN-based LD coupled with a single crystal Ce-doped yttrium aluminum garnet (YAG:Ce) sample was investigated for white light illumination applications. Under CW operation, a single phosphor-converted LD (pc-LD) die produced a peak luminous efficacy of 86.7 lm/W at 1.4 A and 4.24 V and a peak luminous flux of 1100 lm at 3.0 A and 4.85 V with a luminous efficacy of 75.6 lm/W. Simulations of a pc-LD confirm that the single crystal YAG:Ce sample did not experience thermal quenching at peak LD operating efficiency. These results show that a single pc-LD die is capable of emitting enough luminous flux for use in a high power white light illumination system.

  3. A radio monitoring survey of ultra-luminous X-ray sources

    Science.gov (United States)

    Körding, E.; Colbert, E.; Falcke, H.

    2005-06-01

    We present the results of a radio monitoring campaign to search for radio emission from nearby ultra-luminous X-ray sources (ULXs). These sources are bright off-nuclear X-ray point sources with luminosities exceeding LX > 1039 erg s-1. A well-defined sample of the 9 nearest ULXs has been monitored eight times over 5 months with the Very Large Array in A and B configuration. Our limiting sensitivity is ≈0.15 mJy (4σ) for radio flares and ≈60 μJy for continuous emission. In M 82 two ULXs seem to have coincident compact radio sources, which are probably supernova remnants. No continuous or flaring radio emission has been detected from any other ULX. Thus, ULXs do not generally emit steady-state radio emission above radio powers of 1.5 × 1017 W/Hz. The non-detections of the continuous emission are consistent with beamed or unbeamed radio emission from accreting black holes of ≤ 103 M⊙ based on the radio/X-ray correlation. Other published radio detections (M 82, NGC 5408) are also discussed in this context. Both detections are significantly above our detection limit. If ULXs have flaring radio emission above 4 × 1017 W/Hz we can give an upper limit on the duty cycle of the flares of 6%. This upper limit is in agreement with the observed number of flares in Galactic radio transients. Additionally we present a yet unreported radio double structure in the nearby low-luminosity AGN NGC 4736.

  4. High resolution radio observations of nuclear and circumnuclear regions of luminous infrared galaxies (LIRGs)

    Energy Technology Data Exchange (ETDEWEB)

    Alberdi, A; Perez-Torres, M A [Instituto de Astrofisica de Andalucia (IAA, CSIC), PO Box 3004, 18080-Granada (Spain); Colina, L [Instituto de Estructura de la Materia - IEM, CSIC, C, Serrano 115, 28005 Madrid (Spain); Torrelles, J M [Instituto de Ciencias del Espacio (ICE, CSIC) and IEEC, Gran Capita 2-4, 08034 Barcelona (Spain)], E-mail: antxon@iaa.es, E-mail: torres@iaa.es, E-mail: colina@damir.iem.csic.es, E-mail: torrelle@ieec.fcr.es

    2008-10-15

    High-resolution radio observations of the nuclear region of Luminous and Ultraluminous Infrared Galaxies (ULIRGs) have shown that its radio structure consists of a compact high surface-brightness central radio source immersed in a diffuse low brightness circumnuclear halo. While the central component could be associated with an AGN or compact star-forming regions where radio supernovae are exploding, it is well known that the circumnuclear regions host bursts of star-formation. The studies of radio supernovae can provide essential information about stellar evolution and CSM/ISM properties in regions hidden by dust at optical and IR wavelengths. In this contribution, we show results from radio interferometric observations from NGC 7469, IRAS 18293-3413 and IRAS 17138-1017 where three extremely bright radio supernovae have been found. High-resolution radio observations of these and other LIRGs would allow us to determine the core-collapse supernova rate in them as well as their star-formation rate.

  5. Relativistic radiative transfer in a moving stratus irradiated by a luminous flat source

    Science.gov (United States)

    Fukue, Jun

    2015-06-01

    Relativistic radiative transfer in a geometrically thin stratus (sheet-like gaseous cloud with finite optical depth), which is moving at a relativistic speed around a luminous flat source, such as accretion disks, and is irradiated by the source, is examined under the special relativistic treatment. Incident radiation is aberrated and Doppler-shifted when it is received by the stratus, and emitted radiation is also aberrated and Doppler-shifted when it leaves the stratus. Considering these relativistic effects, we analytically obtain the emergent intensity as well as other radiative quantities in the purely scattering case for both infinite and finite strati. We mainly consider the frequency-integrated case, but also briefly show the frequency-dependent one. We also solve the relativistic radiative transfer equation numerically, and compare the results with the analytical solutions. In the infinite stratus, the mean intensity in the comoving and inertial frames decreases and becomes constant, as the stratus speed increases. The flux in the comoving frame decreases exponentially with the optical depth. The emergent intensity decreases as the speed increases, since the incident photons are redshifted at the bottom-side of the stratus. In the finite stratus, the mean intensity in the comoving and inertial frames quickly increases in the top-side region due to the aberrated photons. The flux in the comoving frame is positive in the range of 0 negative for β ≳ 0.5. The behavior of the emergent intensity is similar to that of the infinite case, although there is an irradiation effect caused by the aberrated photons.

  6. High-protein diet modifies colonic microbiota and luminal environment but not colonocyte metabolism in the rat model: the increased luminal bulk connection.

    Science.gov (United States)

    Liu, Xinxin; Blouin, Jean-Marc; Santacruz, Arlette; Lan, Annaïg; Andriamihaja, Mireille; Wilkanowicz, Sabina; Benetti, Pierre-Henri; Tomé, Daniel; Sanz, Yolanda; Blachier, François; Davila, Anne-Marie

    2014-08-15

    High-protein diets are used for body weight reduction, but consequences on the large intestine ecosystem are poorly known. Here, rats were fed for 15 days with either a normoproteic diet (NP, 14% protein) or a hyperproteic-hypoglucidic isocaloric diet (HP, 53% protein). Cecum and colon were recovered for analysis. Short- and branched-chain fatty acids, as well as lactate, succinate, formate, and ethanol contents, were markedly increased in the colonic luminal contents of HP rats (P diet, whereas the amount of butyrate in feces was increased (P diet consumption allows maintenance in the luminal butyrate concentration and thus its metabolism in colonocytes despite modified microbiota composition and increased substrate availability. Copyright © 2014 the American Physiological Society.

  7. Radio Observations of Ultra-Luminous X-Ray Sources ---Microblazars or Intermediate-Mass Black Holes?---

    Science.gov (United States)

    Körding, E.; Colbert, E.; Falcke, H.

    In recent years Ultra-Luminous X-Ray sources (ULXs) received wide attention, however, their true nature is not yet understood. Many explanations have been suggested, including intermediate-mass black holes, super-Eddington accretion flows, anisotropic emission, and relativistic beaming of microquasars. We model the logN-logS distribution of ULXs assuming that each neutron star or black hole XRB can be described by an accretion disk plus jet model, where the jet is relativistically beamed. The distribution can be either fit by intermediate-mass black holes or by stellar mass black holes with mildly relativistic jets. Even though the jet is intrinsically weaker than the accretion disk, relativistic beaming can in the latter approach lead to the high fluxes observed. To further explore the possibility of microblazars contributing to the ULX phenomenon, we have embarked on a radio-monitoring study of ULXs in nearby galaxies with the VLA. However, up to now no radio flare has been detected. Using the radio/X-ray correlation the upper limits on the radio flux can be converted into upper limits for the black hole masses of MBH ≲ 10^3 M⊙.

  8. Hybrid metal grid-polymer-carbon nanotube electrodes for high luminance organic light emitting diodes

    International Nuclear Information System (INIS)

    Sam, F Laurent M; Dabera, G Dinesha M R; Lai, Khue T; Mills, Christopher A; Rozanski, Lynn J; Silva, S Ravi P

    2014-01-01

    Organic light emitting diodes (OLEDs) incorporating grid transparent conducting electrodes (TCEs) with wide grid line spacing suffer from an inability to transfer charge carriers across the gaps in the grids to promote light emission in these areas. High luminance OLEDs fabricated using a hybrid TCE composed of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS PH1000) or regioregular poly(3-hexylthiophene)-wrapped semiconducting single-walled carbon nanotubes (rrP3HT-SWCNT) in combination with a nanometre thin gold grid are reported here. OLEDs fabricated using the hybrid gold grid/PH1000 TCE have a luminance of 18 000 cd m −2 at 9 V; the same as the reference indium tin oxide (ITO) OLED. The gold grid/rrP3HT-SWCNT OLEDs have a lower luminance of 8260 cd m −2 at 9 V, which is likely due to a rougher rrP3HT-SWCNT surface. These results demonstrate that the hybrid gold grid/PH1000 TCE is a promising replacement for ITO in future plastic electronics applications including OLEDs and organic photovoltaics. For applications where surface roughness is not critical, e.g. electrochromic devices or discharge of static electricity, the gold grid/rrP3HT-SWCNT hybrid TCE can be employed. (paper)

  9. Spectrally adjustable quasi-monochromatic radiance source based on LEDs and its application for measuring spectral responsivity of a luminance meter

    International Nuclear Information System (INIS)

    Hirvonen, Juha-Matti; Poikonen, Tuomas; Vaskuri, Anna; Kärhä, Petri; Ikonen, Erkki

    2013-01-01

    A spectrally adjustable radiance source based on light-emitting diodes (LEDs) has been constructed for spectral responsivity measurements of radiance and luminance meters. A 300 mm integrating sphere source with adjustable output port is illuminated using 30 thermally stabilized narrow-band LEDs covering the visible wavelength range of 380–780 nm. The functionality of the measurement setup is demonstrated by measuring the relative spectral responsivities of a luminance meter and a photometer head with cosine-corrected input optics. (paper)

  10. Accretion Disk Spectra of the Ultra-Luminous X-Ray Sources in Nearby Spiral Galaxies and Galactic Superluminal Jet Sources

    Energy Technology Data Exchange (ETDEWEB)

    Mizuno, T

    2003-12-11

    Ultra-luminous Compact X-ray Sources (ULXs) in nearby spiral galaxies and Galactic superluminal jet sources share the common spectral characteristic that they have unusually high disk temperatures which cannot be explained in the framework of the standard optically thick accretion disk in the Schwarzschild metric. On the other hand, the standard accretion disk around the Kerr black hole might explain the observed high disk temperature, as the inner radius of the Kerr disk gets smaller and the disk temperature can be consequently higher. However, we point out that the observable Kerr disk spectra becomes significantly harder than Schwarzschild disk spectra only when the disk is highly inclined. This is because the emission from the innermost part of the accretion disk is Doppler-boosted for an edge-on Kerr disk, while hardly seen for a face-on disk. The Galactic superluminal jet sources are known to be highly inclined systems, thus their energy spectra may be explained with the standard Kerr disk with known black hole masses. For ULXs, on the other hand, the standard Kerr disk model seems implausible, since it is highly unlikely that their accretion disks are preferentially inclined, and, if edge-on Kerr disk model is applied, the black hole mass becomes unreasonably large (> 300 M{sub solar}). Instead, the slim disk (advection dominated optically thick disk) model is likely to explain the observed super-Eddington luminosities, hard energy spectra, and spectral variations of ULXs. We suggest that ULXs are accreting black holes with a few tens of solar mass, which is not unexpected from the standard stellar evolution scenario, and that their X-ray emission is from the slim disk shining at super-Eddington luminosities.

  11. High-protein diet modifies colonic microbiota and luminal environment but not colonocyte metabolism in the rat model: the increased luminal bulk connection

    OpenAIRE

    LIU, Xinxin; BLOUIN, Jean-Marc; Santacruz, Arlette; Lan, Annaig; Andriamihaja, Mireille; Wilkanowicz, Sabina; Benetti, Pierre-Henri; Tomé, Daniel; Sanz, Yolanda; Blachier, Francois; Davila-Gay, Anne-Marie

    2014-01-01

    High-protein diets are used for body weight reduction, but consequences on the large intestine ecosystem are poorly known. Here, rats were fed for 15 days with either a normoproteic diet (NP, 14% protein) or a hyperproteic-hypoglucidic isocaloric diet (HP, 53% protein). Cecum and colon were recovered for analysis. Short- and branched-chain fatty acids, as well as lactate, succinate, formate, and ethanol contents, were markedly increased in the colonic luminal contents of HP rats (P < 0.05 or ...

  12. Study of luminous phenomena observed on contaminated metallic surfaces submitted to high RF fields

    International Nuclear Information System (INIS)

    Maissa, S.; Junquera, T.; Fouaidy, M.; Le Goff, A.; Bonin, B.; Luong, M.; Safa, H.; Tan, J.

    1995-01-01

    The RF field emission from a sample subjected to high RF fields in a copper cavity has been investigated. The study is focused on the luminous emissions occurring on the RF surface simultaneously with the electron emission. The optical apparatus attached to the cavity permits to observe the evolution of the emitters and the direct effects of the surface conditioning. Also, the parameters of the emitted radiation (intensity, glowing duration, spectral distribution) may provide additional informations on the field emission phenomena. Some results concerning samples intentionally contaminated with particles (metallic or dielectric) are presented. (K.A.)

  13. High-Risk Premenopausal Luminal A Breast Cancer Patients Derive no Benefit from Adjuvant Cyclophosphamide-based Chemotherapy

    DEFF Research Database (Denmark)

    Nielsen, Torsten O; Jensen, Maj-Brit; Burugu, Samantha

    2017-01-01

    Purpose: Luminal A breast cancers have better prognosis than other molecular subtypes. Luminal A cancers may also be insensitive to adjuvant chemotherapy, although there is little high-level evidence to confirm this concept. The primary hypothesis in this formal prospective-retrospective analysis...... was to assess interaction between subtype (Luminal A vs. other) and treatment (chemotherapy vs. not) for the primary endpoint (10-year invasive disease-free survival) of a breast cancer trial randomizing women to adjuvant chemotherapy, analyzed in multivariate Cox proportional hazards models using the Wald...... interval (CI), 0.53-2.14; P = 0.86], whereas patients with non-luminal A subtypes did (HR, 0.50; 95% CI, 0.38-0.66; P breast cancers did not benefit from adjuvant...

  14. High luminance monochrome vs. color displays: impact on performance and search

    Science.gov (United States)

    Krupinski, Elizabeth A.; Roehrig, Hans; Matsui, Takashi

    2011-03-01

    To determine if diagnostic accuracy and visual search efficiency with a high luminance medical-grade color display are equivalent to a high luminance medical-grade monochrome display. Six radiologists viewed DR chest images, half with a solitary pulmonary nodule and half without. Observers reported whether or not a nodule was present and their confidence in that decision. Total viewing time per image was recorded. On a subset of 15 cases eye-position was recorded. Confidence data were analyzed using MRMC ROC techniques. There was no statistically significant difference (F = 0.0136, p = 0.9078) between color (mean Az = 0.8981, se = 0.0065) and monochrome (mean Az = 0.8945, se = 0.0148) diagnostic performance. Total viewing time per image did not differ significantly (F = 0.392, p = 0.5315) as a function of color (mean = 27.36 sec, sd = 12.95) vs monochrome (mean = 28.04, sd = 14.36) display. There were no significant differences in decision dwell times (true and false, positive and negative) overall for color vs monochrome displays (F = 0.133, p = 0.7154). The true positive (TP) and false positive (FP) decisions were associated with the longest dwell times, the false negatives (FN) with slightly shorter dwell times, and the true negative decisions (TN) with the shortest (F = 50.552, p radiology.

  15. Integrated chemical process for exothermic wave synthesis of high luminance YAG:Ce phosphors

    International Nuclear Information System (INIS)

    Won, C.W.; Nersisyan, H.H.; Won, H.I.; Youn, J.W.

    2011-01-01

    In this paper, high-luminance yellow-emitting Y 3 Al 5 O 12 :Ce 3+ phosphor (YAG:Ce) microparticles were prepared in a solid flame using a 1.425Y 2 O 3 +2.5Al 2 O 3 +0.15CeO 2 +k(KClO 3 +urea)+mNH 4 F precursor mixture (here k is the number of moles of the KClO 3 +urea red-ox mixture, and m is the number of moles of NH 4 F). The self-sustaining combustion process for the entire reaction sample was provided by the heat generated from the KClO 3 +urea mixture. Parametric studies demonstrated that the maximum temperature in the combustion wave varied from 885 to 1200 deg. C for k=2.0-3.0 mole and m=0-1.5 mole. X-ray analysis results showed that the product obtained in the solid flame consisted of Y 3 Al 5 O 12 :Ce 3+ and KCl phases. Therefore, after dissolving potassium chloride in distillated water, pure-phase YAG:Ce phosphor powder was obtained. The as-prepared YAG:Ce phosphor particles had diameters of 10-25 μm and good dispersity and exhibited luminescence properties comparable to those of YAG:Ce phosphor powders prepared by conventional high-temperature processing. - Highlights: → A new solid-flame strategy was developed for synthesizing high-luminance YAG:Ce phosphor. → Adding KClO 3 +CO(NH 2 ) 2 +NH 4 F mixture to oxide powders provides a low-temperature combustion process. → YAG:Ce phosphor particles 10-25 μm in diameter were obtained at 1000-1100 deg. C within tens of seconds. → As-prepared YAG:Ce emission intensity was 90.1-103.2% compared to that of the reference sample.

  16. Manufacturing polymer light emitting diode with high luminance efficiency by solution process

    Science.gov (United States)

    Kim, Miyoung; Jo, SongJin; Yang, Ho Chang; Yoon, Dang Mo; Kwon, Jae-Taek; Lee, Seung-Hyun; Choi, Ju Hwan; Lee, Bum-Joo; Shin, Jin-Koog

    2012-06-01

    While investigating polymer light emitting diodes (polymer-LEDs) fabricated by solution process, surface roughness influences electro-optical (E-O) characteristics. We expect that E-O characteristics such as luminance and power efficiency related to surface roughness and layer thickness of emitting layer with poly-9-Vinylcarbazole. In this study, we fabricated polymer organic light emitting diodes by solution process which guarantees easy, eco-friendly and low cost manufacturing for flexible display applications. In order to obtain high luminescence efficiency, E-O characteristics of these devices by varying parameters for printing process have been investigated. Therefore, we optimized process condition for polymer-LEDs by adjusting annealing temperatures of emission, thickness of emission layer showing efficiency (10.8 cd/A) at 10 mA/cm2. We also checked wavelength dependent electroluminescence spectrum in order to find the correlation between the variation of efficiency and the thickness of the layer.

  17. High expression of ZNF703 independent of amplification indicates worse prognosis in patients with luminal B breast cancer

    International Nuclear Information System (INIS)

    Reynisdottir, Inga; Arason, Adalgeir; Einarsdottir, Berglind O; Gunnarsson, Haukur; Staaf, Johan; Vallon-Christersson, Johan; Jonsson, Goran; Ringnér, Markus; Agnarsson, Bjarni A; Olafsdottir, Kristrun; Fagerholm, Rainer; Einarsdottir, Thorbjorg; Johannesdottir, Gudrun; Johannsson, Oskar Thor; Nevanlinna, Heli; Borg, Ake; Barkardottir, Rosa Bjork

    2013-01-01

    Amplification of 8p12-p11 is relatively common in breast cancer and several genes within the region have been suggested to affect breast tumor progression. The aim of the study was to map the amplified 8p12-p11 region in a large set of breast tumors in an effort to identify the genetic driver and to explore its impact on tumor progression and prognosis. Copy number alterations (CNAs) were mapped in 359 tumors, and gene expression data from 577 tumors (359 tumors included) were correlated with CNA, clinical–pathological factors, and protein expression (39 tumors). 8p12-p11 was amplified in 11.4% of tumors. The smallest region of amplification harbored one full-length gene, ZNF703. ZNF703 mRNA expression was significantly higher in estrogen receptor (ER)-positive than ER-negative tumors (P = 2 × 10 −16 ), a reflection of high expression in luminal tumors. Forty-eight percent of tumors with ZNF703 amplification were luminal B tumors in which the best correlation between DNA copy number and mRNA was seen (P = 1.2 × 10 −7 ) as well as correlation between mRNA and protein expression (P = 0.02). High ZNF703 mRNA correlated with poor survival in patients with ER-positive luminal B tumors (log rank P = 0.04). Furthermore, high ZNF703 mRNA expression correlated with poor outcome in patients with ZNF703 copy number neutral, ER-positive, luminal B tumors (log rank P = 0.004). The results support ZNF703 as the driver gene of the 8p12 amplification and suggest that independent of amplification, high expression of the gene affects prognosis in luminal B tumors. Our mapping of 8p12-p11 and analyses of ZNF703 mRNA and protein expression in breast tumors support ZNF703 as an oncogene in luminal B tumors. High ZNF703 expression, independent of the amplification, correlated with worse prognosis for the breast cancer patients with ER-positive luminal tumors, particularly of the luminal B subtype

  18. Salient features in the preparation of gaseous tritium filled luminous light sources

    International Nuclear Information System (INIS)

    Mathew, K.M.; Ravi, S.; Subramanian, T.K.; Ananthakrishnan, M.

    2003-01-01

    Beta radiation emanating from gaseous tritium in close proximity with copper activated zinc sulphide phosphor provides self sustained light sources and these sources are used for nocturnal illumination of liquid crystal display in digital watches and clocks, product advertisements, exit signs etc. We report herein the preparation of low specific radioactivity gaseous tritium (29.5 Ci/m mole; 1.09 TBq/m mole) filled light sources and its effect on light output. (author)

  19. A Massive, Cooling-Flow-Induced Starburst in the Core of a Highly Luminous Galaxy Cluster

    Science.gov (United States)

    McDonald, M.; Bayliss, M.; Benson, B. A.; Foley, R. J.; Ruel, J.; Sullivan, P.; Veilleux, S.; Aird, K. A.; Ashby, M. L. N.; Bautz, M.; hide

    2012-01-01

    In the cores of some galaxy clusters the hot intracluster plasma is dense enough that it should cool radiatively in the cluster s lifetime, leading to continuous "cooling flows" of gas sinking towards the cluster center, yet no such cooling flow has been observed. The low observed star formation rates and cool gas masses for these "cool core" clusters suggest that much of the cooling must be offset by astrophysical feedback to prevent the formation of a runaway cooling flow. Here we report X-ray, optical, and infrared observations of the galaxy cluster SPT-CLJ2344-4243 at z = 0.596. These observations reveal an exceptionally luminous (L(sub 2-10 keV) = 8.2 10(exp 45) erg/s) galaxy cluster which hosts an extremely strong cooling flow (M(sub cool) = 3820 +/- 530 Stellar Mass/yr). Further, the central galaxy in this cluster appears to be experiencing a massive starburst (740 +/- 160 Stellar Mass/ yr), which suggests that the feedback source responsible for preventing runaway cooling in nearby cool core clusters may not yet be fully established in SPT-CLJ2344-4243. This large star formation rate implies that a significant fraction of the stars in the central galaxy of this cluster may form via accretion of the intracluster medium, rather than the current picture of central galaxies assembling entirely via mergers.

  20. A LUMINOUS Be+WHITE DWARF SUPERSOFT SOURCE IN THE WING OF THE SMC: MAXI J0158-744

    International Nuclear Information System (INIS)

    Li, K. L.; Kong, Albert K. H.; Lu, Ting-Ni; Charles, P. A.; Bartlett, E. S.; Coe, M. J.; McBride, V.; Rajoelimanana, A.; Udalski, A.; Masetti, N.; Franzen, Thomas

    2012-01-01

    We present a multi-wavelength analysis of the very fast X-ray transient MAXI J0158-744, which was detected by MAXI/GSC on 2011 November 11. The subsequent exponential decline of the X-ray flux was followed with Swift observations, all of which revealed spectra with low temperatures (∼100 eV), indicating that MAXI J0158-744 is a new Supersoft Source (SSS). The Swift X-ray spectra near maximum show features around 0.8 keV that we interpret as possible absorption from O VIII and emission from O, Fe, and Ne lines. We obtained SAAO and ESO optical spectra of the counterpart early in the outburst and several weeks later. The early spectrum is dominated by strong Balmer and He I emission, together with weaker He II emission. The later spectrum reveals absorption features that indicate a B1/2IIIe spectral type, and all spectral features are at velocities consistent with the Small Magellanic Cloud. At this distance, it is a luminous SSS (>10 37 erg s –1 ) but whose brief peak luminosity of >10 39 erg s –1 in the 2-4 keV band makes it the brightest SSS yet seen at ''hard'' X-rays. We propose that MAXI J0158-744 is a Be-WD binary, and the first example to possibly enter ULX territory. The brief hard X-ray flash could possibly be a result of the interaction of the ejected nova shell with the B star wind in which the white dwarf (WD) is embedded. This makes MAXI J0158-744 only the third Be/WD system in the Magellanic Clouds, but it is by far the most luminous. The properties of MAXI J0158-744 give weight to previous suggestions that SSS in nearby galaxies are associated with early-type stellar systems.

  1. Luminous flux improvement of xenon fluorescent lamps by applying synchronized high-voltage pulse to the auxiliary external electrode

    Energy Technology Data Exchange (ETDEWEB)

    Motomura, Hideki; Oka, Kojiro; Sogabe, Toru; Jinno, Masafumi, E-mail: hmoto@mayu.ee.ehime-u.ac.jp [Department of Electrical and Electronic Engineering, Ehime University 3 Bunkyo-cho, Matsuyama, Ehime 790-8577 (Japan)

    2011-06-08

    As the environmental awareness of people becomes stronger, the demand for mercury-free light sources also becomes stronger. The authors have been developing cold cathode fluorescent lamps in which xenon gas is filled as an ultraviolet radiator instead of mercury. Previously the authors reported the luminous flux enhancement method using a grounded auxiliary external electrode (AEE). In this paper, in order to improve the luminous flux much more, a positive voltage pulse which was synchronized to the main driving negative voltage pulse was applied to the AEE. As a result, the maximum input power increased under which the positive column did not constrict and the luminous flux improved by 70% at the xenon filling pressure of 6.7 kPa. It is proved that the positive voltage pulse application to the AEE with the amplitude of more than 2 kV expands the positive column in the radial direction. It is attributed to the phenomenon that the residual ions and electrons, which are generated by dielectric barrier discharge between the AEE and the anode during the falling edge of the negative pulse to the cathode, spread the discharge path from the anode towards the AEE during the cold cathode discharge mode. By increasing the xenon filling pressure, luminous efficacy was improved to 25 lm W{sup -1}.

  2. High luminous flux from single crystal phosphor-converted laser-based white lighting system

    KAUST Repository

    Cantore, Michael; Pfaff, Nathan; Farrell, Robert M.; Speck, James S.; Nakamura, Shuji; DenBaars, Steven P.

    2015-01-01

    efficacy of 86.7 lm/W at 1.4 A and 4.24 V and a peak luminous flux of 1100 lm at 3.0 A and 4.85 V with a luminous efficacy of 75.6 lm/W. Simulations of a pc-LD confirm that the single crystal YAG:Ce sample did not experience thermal quenching at peak LD

  3. A High-Speed Spectroscopy System for Observing Lightning and Transient Luminous Events

    Science.gov (United States)

    Boggs, L.; Liu, N.; Austin, M.; Aguirre, F.; Tilles, J.; Nag, A.; Lazarus, S. M.; Rassoul, H.

    2017-12-01

    Here we present a high-speed spectroscopy system that can be used to record atmospheric electrical discharges, including lightning and transient luminous events. The system consists of a Phantom V1210 high-speed camera, a Volume Phase Holographic (VPH) grism, an optional optical slit, and lenses. The spectrograph has the capability to record videos at speeds of 200,000 frames per second and has an effective wavelength band of 550-775 nm for the first order spectra. When the slit is used, the system has a spectral resolution of about 0.25 nm per pixel. We have constructed a durable enclosure made of heavy duty aluminum to house the high-speed spectrograph. It has two fans for continuous air flow and a removable tray to mount the spectrograph components. In addition, a Watec video camera (30 frames per second) is attached to the top of the enclosure to provide a scene view. A heavy duty Pelco pan/tilt motor is used to position the enclosure and can be controlled remotely through a Rasperry Pi computer. An observation campaign has been conducted during the summer and fall of 2017 at the Florida Institute of Technology. Several close cloud-to-ground discharges were recorded at 57,000 frames per second. The spectrum of a downward stepped negative leader and a positive cloud-to-ground return stroke will be reported on.

  4. Spectroscopy of Luminous z > 7 Galaxy Candidates and Sources of Contamination in z > 7 Galaxy Searches

    Science.gov (United States)

    Capak, P.; Mobasher, B.; Scoville, N. Z.; McCracken, H.; Ilbert, O.; Salvato, M.; Menéndez-Delmestre, K.; Aussel, H.; Carilli, C.; Civano, F.; Elvis, M.; Giavalisco, M.; Jullo, E.; Kartaltepe, J.; Leauthaud, A.; Koekemoer, A. M.; Kneib, J.-P.; LeFloch, E.; Sanders, D. B.; Schinnerer, E.; Shioya, Y.; Shopbell, P.; Tanaguchi, Y.; Thompson, D.; Willott, C. J.

    2011-04-01

    We present three bright z +-dropout candidates selected from deep near-infrared (NIR) imaging of the COSMOS 2 deg2 field. All three objects match the 0.8-8 μm colors of other published z > 7 candidates but are 3 mag brighter, facilitating further study. Deep spectroscopy of two of the candidates covering 0.64-1.02 μm with Keck-DEIMOS and all three covering 0.94-1.10 μm and 1.52-1.80 μm with Keck-NIRSPEC detects weak spectral features tentatively identified as Lyα at z = 6.95 and z = 7.69 in two of the objects. The third object is placed at z ~ 1.6 based on a 24 μm and weak optical detection. A comparison with the spectral energy distributions of known z 1 μm properties of all three objects can be matched to optically detected sources with photometric redshifts at z ~ 1.8, so the non-detection in the i + and z + bands is the primary factor which favors a z > 7 solution. If any of these objects are at z ~ 7, the bright end of the luminosity function is significantly higher at z > 7 than suggested by previous studies, but consistent within the statistical uncertainty and the dark matter halo distribution. If these objects are at low redshift, the Lyman break selection must be contaminated by a previously unknown population of low-redshift objects with very strong breaks in their broadband spectral energy distributions and blue NIR colors. The implications of this result on luminosity function evolution at high redshift are discussed. We show that the primary limitation of z > 7 galaxy searches with broad filters is the depth of the available optical data. Based on observations with the W. M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and the National Aeronautics and Space Administration and made possible by the generous financial support of the W. M. Keck Foundation; the Spitzer Space Telescope, which is operated by the Jet Propulsion Laboratory, California

  5. Probing the bias of radio sources at high redshift

    CSIR Research Space (South Africa)

    Passmoor, S

    2012-11-01

    Full Text Available The relationship between the clustering of dark matter and that of luminous matter is often described using the bias parameter. Here, we provide a new method to probe the bias of intermediate-to-high-redshift radio continuum sources for which...

  6. High current ion sources

    International Nuclear Information System (INIS)

    Brown, I.G.

    1989-06-01

    The concept of high current ion source is both relative and evolutionary. Within the domain of one particular kind of ion source technology a current of microamperers might be 'high', while in another area a current of 10 Amperes could 'low'. Even within the domain of a single ion source type, what is considered high current performance today is routinely eclipsed by better performance and higher current output within a short period of time. Within their fields of application, there is a large number of kinds of ion sources that can justifiably be called high current. Thus, as a very limited example only, PIGs, Freemen sources, ECR sources, duoplasmatrons, field emission sources, and a great many more all have their high current variants. High current ion beams of gaseous and metallic species can be generated in a number of different ways. Ion sources of the kind developed at various laboratories around the world for the production of intense neutral beams for controlled fusion experiments are used to form large area proton deuteron beams of may tens of Amperes, and this technology can be used for other applications also. There has been significant progress in recent years in the use of microwave ion sources for high current ion beam generation, and this method is likely to find wide application in various different field application. Finally, high current beams of metal ions can be produced using metal vapor vacuum arc ion source technology. After a brief consideration of high current ion source design concepts, these three particular methods are reviewed in this paper

  7. A LUMINOUS Be+WHITE DWARF SUPERSOFT SOURCE IN THE WING OF THE SMC: MAXI J0158-744

    Energy Technology Data Exchange (ETDEWEB)

    Li, K. L.; Kong, Albert K. H.; Lu, Ting-Ni [Institute of Astronomy and Department of Physics, National Tsing Hua University, Taiwan (China); Charles, P. A.; Bartlett, E. S.; Coe, M. J. [School of Physics and Astronomy, University of Southampton, Highfield, Southampton SO17 1BJ (United Kingdom); McBride, V.; Rajoelimanana, A. [South African Astronomical Observatory, P.O. Box 9, Observatory 7935 (South Africa); Udalski, A. [Warsaw University Observatory, Aleje Ujazdowskie 4, 00-478 Warsaw (Poland); Masetti, N. [INAF-Istituto di Astrofisica Spaziale e Fisica Cosmica di Bologna, via Gobetti 101, I-40129 Bologna (Italy); Franzen, Thomas [CSIRO Astronomy and Space Science, PO Box 76, Epping NSW 1710 (Australia)

    2012-12-20

    We present a multi-wavelength analysis of the very fast X-ray transient MAXI J0158-744, which was detected by MAXI/GSC on 2011 November 11. The subsequent exponential decline of the X-ray flux was followed with Swift observations, all of which revealed spectra with low temperatures ({approx}100 eV), indicating that MAXI J0158-744 is a new Supersoft Source (SSS). The Swift X-ray spectra near maximum show features around 0.8 keV that we interpret as possible absorption from O VIII and emission from O, Fe, and Ne lines. We obtained SAAO and ESO optical spectra of the counterpart early in the outburst and several weeks later. The early spectrum is dominated by strong Balmer and He I emission, together with weaker He II emission. The later spectrum reveals absorption features that indicate a B1/2IIIe spectral type, and all spectral features are at velocities consistent with the Small Magellanic Cloud. At this distance, it is a luminous SSS (>10{sup 37} erg s{sup -1}) but whose brief peak luminosity of >10{sup 39} erg s{sup -1} in the 2-4 keV band makes it the brightest SSS yet seen at ''hard'' X-rays. We propose that MAXI J0158-744 is a Be-WD binary, and the first example to possibly enter ULX territory. The brief hard X-ray flash could possibly be a result of the interaction of the ejected nova shell with the B star wind in which the white dwarf (WD) is embedded. This makes MAXI J0158-744 only the third Be/WD system in the Magellanic Clouds, but it is by far the most luminous. The properties of MAXI J0158-744 give weight to previous suggestions that SSS in nearby galaxies are associated with early-type stellar systems.

  8. The nature of luminous Ly α emitters at z ˜ 2-3: maximal dust-poor starbursts and highly ionizing AGN

    Science.gov (United States)

    Sobral, David; Matthee, Jorryt; Darvish, Behnam; Smail, Ian; Best, Philip N.; Alegre, Lara; Röttgering, Huub; Mobasher, Bahram; Paulino-Afonso, Ana; Stroe, Andra; Oteo, Iván

    2018-06-01

    Deep narrow-band surveys have revealed a large population of faint Ly α emitters (LAEs) in the distant Universe, but relatively little is known about the most luminous sources ({L}_{Lyα } ≳ 10^{42.7} erg s-1; L_{Lyα }≳ L^*_{Lyα }). Here we present the spectroscopic follow-up of 21 luminous LAEs at z ˜ 2-3 found with panoramic narrow-band surveys over five independent extragalactic fields (≈4 × 106 Mpc3 surveyed at z ˜ 2.2 and z ˜ 3.1). We use WHT/ISIS, Keck/DEIMOS, and VLT/X-SHOOTER to study these sources using high ionization UV lines. Luminous LAEs at z ˜ 2-3 have blue UV slopes (β =-2.0^{+0.3}_{-0.1}) and high Ly α escape fractions (50^{+20}_{-15} per cent) and span five orders of magnitude in UV luminosity (MUV ≈ -19 to -24). Many (70 per cent) show at least one high ionization rest-frame UV line such as C IV, N V, C III], He II or O III], typically blue-shifted by ≈100-200 km s-1 relative to Ly α. Their Ly α profiles reveal a wide variety of shapes, including significant blue-shifted components and widths from 200 to 4000 km s-1. Overall, 60 ± 11 per cent appear to be active galactic nucleus (AGN) dominated, and at LLyα > 1043.3 erg s-1 and/or MUV sharp transition in the nature of LAEs, from star formation dominated to AGN dominated.

  9. Preliminary analysis on faint luminous lightning events recorded by multiple high speed cameras

    Science.gov (United States)

    Alves, J.; Saraiva, A. V.; Pinto, O.; Campos, L. Z.; Antunes, L.; Luz, E. S.; Medeiros, C.; Buzato, T. S.

    2013-12-01

    The objective of this work is the study of some faint luminous events produced by lightning flashes that were recorded simultaneously by multiple high-speed cameras during the previous RAMMER (Automated Multi-camera Network for Monitoring and Study of Lightning) campaigns. The RAMMER network is composed by three fixed cameras and one mobile color camera separated by, in average, distances of 13 kilometers. They were located in the Paraiba Valley (in the cities of São José dos Campos and Caçapava), SP, Brazil, arranged in a quadrilateral shape, centered in São José dos Campos region. This configuration allowed RAMMER to see a thunderstorm from different angles, registering the same lightning flashes simultaneously by multiple cameras. Each RAMMER sensor is composed by a triggering system and a Phantom high-speed camera version 9.1, which is set to operate at a frame rate of 2,500 frames per second with a lens Nikkor (model AF-S DX 18-55 mm 1:3.5 - 5.6 G in the stationary sensors, and a lens model AF-S ED 24 mm - 1:1.4 in the mobile sensor). All videos were GPS (Global Positioning System) time stamped. For this work we used a data set collected in four RAMMER manual operation days in the campaign of 2012 and 2013. On Feb. 18th the data set is composed by 15 flashes recorded by two cameras and 4 flashes recorded by three cameras. On Feb. 19th a total of 5 flashes was registered by two cameras and 1 flash registered by three cameras. On Feb. 22th we obtained 4 flashes registered by two cameras. Finally, in March 6th two cameras recorded 2 flashes. The analysis in this study proposes an evaluation methodology for faint luminous lightning events, such as continuing current. Problems in the temporal measurement of the continuing current can generate some imprecisions during the optical analysis, therefore this work aim to evaluate the effects of distance in this parameter with this preliminary data set. In the cases that include the color camera we analyzed the RGB

  10. LEONA: Transient Luminous Event and Thunderstorm High Energy Emission Collaborative Network in Latin America

    Science.gov (United States)

    Sao Sabbas, F. T.

    2012-12-01

    This project has the goal of establishing the Collaborative Network LEONA, to study the electrodynamical coupling of the atmospheric layers signaled by Transient Luminous Events - TLEs and high energy emissions from thunderstorms. We will develop and install a remotely controlled network of cameras to perform TLE observations in different locations in South America and one neutron detector in southern Brazil. The camera network will allow building a continuous data set of the phenomena studied in this continent. The first two trial units of the camera network are already installed, in Brazil and Peru, and two more will be installed until December 2012, in Argentina and Brazil. We expect to determine the TLE geographic distribution, occurrence rate, morphology, and possible coupling with other geophysical phenomena in South America, such as the South Atlantic Magnetic Anomaly - SAMA. We also expect to study thunderstorm neutron emissions in a region of intense electrical activity, measuring neutron fluxes with high time resolution simultaneously with TLEs and lightning for the first time in South America. Using an intensified high-speed camera for TLE observation during 2 campaigns we expect to be able to determine the duration and spatial- temporal development of the TLEs observed, to study the structure and initiation of sprites and to measure the velocity of development of sprite structures and the sprite delay. The camera was acquired via the FAPESP project DEELUMINOS (2005-2010), which also nucleated our research group Atmospheric Electrodynamical Coupling - ACATMOS. LEONA will nucleate this research in other institutions in Brazil and other countries in South America, providing continuity for this important research in our region. The camera network will be an unique tool to perform consistent long term TLE observation, and in fact is the only way to accumulate a data set for a climatological study of South America, since satellite instrumentation turns off in

  11. High prevalence of luminal B breast cancer intrinsic subtype in Colombian women.

    Science.gov (United States)

    Serrano-Gomez, Silvia Juliana; Sanabria-Salas, Maria Carolina; Hernández-Suarez, Gustavo; García, Oscar; Silva, Camilo; Romero, Alejandro; Mejía, Juan Carlos; Miele, Lucio; Fejerman, Laura; Zabaleta, Jovanny

    2016-07-01

    Breast cancer is the most frequent malignancy in women worldwide. Distinct intrinsic subtypes of breast cancer have different prognoses, and their relative prevalence varies significantly among ethnic groups. Little is known about the prevalence of breast cancer intrinsic subtypes and their association with clinicopathological data and genetic ancestry in Latin Americans. Immunohistochemistry surrogates from the 2013 St. Gallen International Expert Consensus were used to classify breast cancers in 301 patients from Colombia into intrinsic subtypes. We analyzed the distribution of subtypes by clinicopathological variables. Genetic ancestry was estimated from a panel of 80 ancestry informative markers. Luminal B breast cancer subtype was the most prevalent in our population (37.2%) followed by luminal A (26.3%), non-basal triple negative (NBTN) (11.6%), basal like (9%), human epidermal growth factor receptor 2 (HER2) enriched (8.6%) and unknown (7.3%). We found statistical significant differences in distribution between Colombian region (P = 0.007), age at diagnosis (P = 0.0139), grade (P studies analyzing the molecular profiles of breast cancer in Colombian women will help us understand the molecular basis of this subtype distribution and compare the molecular characteristics of the different intrinsic subtypes in Colombian patients. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Colon luminal content and epithelial cell morphology are markedly modified in rats fed with a high-protein diet

    OpenAIRE

    Andriamihaja, Mireille; Davila-Gay, Anne-Marie; Eklou, Mamy; Petit, Nathalie; Delpal, Serge; Allek, Fadhila; Blais, Anne; Delteil, Corine; Tomé, Daniel; Blachier, Francois

    2010-01-01

    Andriamihaja M, Davila A, Eklou-Lawson M, Petit N, Delpal S, Allek F, Blais A, Delteil C, Tome D, Blachier F. Colon luminal content and epithelial cell morphology are markedly modified in rats fed with a high-protein diet. Am J Physiol Gastrointest Liver Physiol 299: G1030-G1037, 2010. First published August 5, 2010; doi: 10.1152/ajpgi.00149.2010.-Hyperproteic diets are used in human nutrition to obtain body weight reduction. Although increased protein ingestion results in an increased transf...

  13. Evaluation of noncoronary sources of left ventricular perfusion to intercoronary collateral-dependent myocardium due to chronic major vessel occlusion: absent contribution of luminal and extracardiac channels

    International Nuclear Information System (INIS)

    Crystal, G.J.; Downey, H.F.; Bashour, F.A.

    1981-01-01

    Liminal contribution to perfusion of collateral-dependent left ventricular (LV) myocardium was evaluated in six dogs. A portion of LV free wall was rendered collateral-dependent by gradual occlusion of left circumflex artery with Ameroid constrictor. Eight to 10 weeks after implantation of constrictor, measurements of LV myocardial flow were made by left atrial injections of 9-10 micro radioactive microspheres. To measure total collateral flow, microspheres were injected under control conditions, and to measure luminal contribution to collateral flow, microspheres were injected after ligation of right coronary artery during extracorporeal perfusion of left common coronary artery (LCCA) with microsphere-free arterial blood, and during stoppage of flow through LCCA. Under control conditions, myocardial blood flow in collateral-dependent region, 1.01 +/- 0.31 ml/min/gm, was not significantly different from that in normal region, 1.06 +/- 0.32 ml/min/gm. Flow from luminal collateral vessels was negligible (less than 0.005 ml/min/gm) in both collateral-dependent and normal myocardium, and was not affected by stoppage of flow through LCCA. These results indicate that luminal collateral vessels, as well as collateral vessels originating from other noncoronary sources, do not contribute significantly to perfusion of normal or collateral-dependent LV myocardium

  14. High speed atom source

    International Nuclear Information System (INIS)

    Hoshino, Hitoshi.

    1990-01-01

    In a high speed atom source, since the speed is not identical between ions and electrons, no sufficient neutralizing effect for ionic rays due to the mixing of the ionic rays and the electron rays can be obtained failing to obtain high speed atomic rays at high density. In view of the above, a speed control means is disposed for equalizing the speed of ions forming ionic rays and the speed of electrons forming electron rays. Further, incident angle of the electron rays and/or ionic rays to a magnet or an electrode is made variable. As a result, the relative speed between the ions and the electrons to the processing direction is reduced to zero, in which the probability of association between the ions and the electrons due to the coulomb force is increased to improve the neutralizing efficiency to easily obtain fine and high density high speed electron rays. Further, by varying the incident angle, a track capable of obtaining an ideal mixing depending on the energy of the neutralized ionic rays is formed. Since the high speed electron rays has such high density, they can be irradiated easily to the minute region of the specimen. (N.H.)

  15. Progress in extremely high brightness LED-based light sources

    Science.gov (United States)

    Hoelen, Christoph; Antonis, Piet; de Boer, Dick; Koole, Rolf; Kadijk, Simon; Li, Yun; Vanbroekhoven, Vincent; Van De Voorde, Patrick

    2017-09-01

    Although the maximum brightness of LEDs has been increasing continuously during the past decade, their luminance is still far from what is required for multiple applications that still rely on the high brightness of discharge lamps. In particular for high brightness applications with limited étendue, e.g. front projection, only very modest luminance values in the beam can be achieved with LEDs compared to systems based on discharge lamps or lasers. With dedicated architectures, phosphor-converted green LEDs for projection may achieve luminance values up to 200-300 Mnit. In this paper we report on the progress made in the development of light engines based on an elongated luminescent concentrator pumped by blue LEDs. This concept has recently been introduced to the market as ColorSpark High Lumen Density LED technology. These sources outperform the maximum brightness of LEDs by multiple factors. In LED front projection, green LEDs are the main limiting factor. With our green modules, we now have achieved peak luminance values of 2 Gnit, enabling LED-based projection systems with over 4000 ANSI lm. Extension of this concept to yellow and red light sources is presented. The light source efficiency has been increased considerably, reaching 45-60 lm/W for green under practical application conditions. The module architecture, beam shaping, and performance characteristics are reviewed, as well as system aspects. The performance increase, spectral range extensions, beam-shaping flexibility, and cost reductions realized with the new module architecture enable a breakthrough in LED-based projection systems and in a wide variety of other high brightness applications.

  16. Constraints on cold dark matter theories from observations of massive x-ray-luminous clusters of galaxies at high redshift

    Science.gov (United States)

    Luppino, G. A.; Gioia, I. M.

    1995-01-01

    During the course of a gravitational lensing survey of distant, X-ray selected Einstein Observatory Extended Medium Sensitivity Survey (EMSS) clusters of galaxies, we have studied six X-ray-luminous (L(sub x) greater than 5 x 10(exp 44)(h(sub 50)(exp -2))ergs/sec) clusters at redshifts exceeding z = 0.5. All of these clusters are apparently massive. In addition to their high X-ray luminosity, two of the clusters at z approximately 0.6 exhibit gravitationally lensed arcs. Furthermore, the highest redshift cluster in our sample, MS 1054-0321 at z = 0.826, is both extremely X-ray luminous (L(sub 0.3-3.5keV)=9.3 x 10(exp 44)(h(sub 50)(exp -2))ergs/sec) and exceedingly rich with an optical richness comparable to an Abell Richness Class 4 cluster. In this Letter, we discuss the cosmological implications of the very existence of these clusters for hierarchical structure formation theories such as standard Omega = 1 CDM (cold dark matter), hybrid Omega = 1 C + HDM (hot dark matter), and flat, low-density Lambda + CDM models.

  17. Tritium pollution in the Swiss luminous compound industry

    International Nuclear Information System (INIS)

    Krejci, K.; Zeller, Jr.

    1979-01-01

    The Swiss luminous compound industry is an important consumer of tritium. About 350kCi go into production of tritium gas-filled light sources and 40kCi into production of tritium luminous compound annually. To illustrate the pollution problem, a factory is mentioned that handles 200kCi annually and a chain of luminizers, processing 20kCi over the same period as tritium luminous compound. This material is manufactured by coating phosphors with tritiated polystyrene having a specific activity up to 200Ci/g. Because of the high specific activity, the radiation damage produces an average activity release of 5.2% annually, which is one of the main reasons for public and occupational exposure. The processing of large quantities of tritium gas requires special equipment, such as units made entirely of stainless steel for purification and hydrogenation, oxidation systems for highly contaminated air, glove boxes, ventilation and monitoring systems. Nevertheless, contamination of air, surfaces, water and workers cannot be avoided. Only in a few cases were MPC-values for tritium content in urine of workers exceeded. From these results, biological half-lives between 5-15 days were estimated. Regular medical examinations showed no significant influence in blood picture parameters, except in one single case with a tritium concentration in urine of 2.8mCi/litre. Entirely different problems arise in most luminizing factories where luminous paint is processed as an open radioactive source. (author)

  18. Are some of the luminous high-latitude stars accretion-powered runaways?

    International Nuclear Information System (INIS)

    Leonard, P.J.T.; Hills, J.G.; Dewey, R.J.

    1992-01-01

    It is well known that (1) runaway stars can be produced via supernova explosions in close binary systems, (2) most of such runaways should possess neutron star companions, and (3) neutron stars receive randomly oriented kicks of ≅ 100 to 200 km s -1 at birth. We find that this kick sometimes has the right amplitude and direction to make the neutron star fall into the runaway. Accretion onto a neutron star is a source of energy that is roughly an order of magnitude more mass efficient than nuclear burning. Thus, runaways containing neutron stars may live much longer than would normally be expected, which would allow them to travel great distances from their birthplaces during their lifetimes. Some of the early B-type stars far from the Galactic plane and the high-latitude F and G-type supergiants may be accretion-powered runaway stars

  19. The Extremely Luminous Quasar Survey (ELQS) in SDSS and the high-z bright-end Quasar Luminosity Function

    Science.gov (United States)

    Schindler, Jan-Torge; Fan, Xiaohui; McGreer, Ian

    2018-01-01

    Studies of the most luminous quasars at high redshift directly probe the evolution of the most massive black holes in the early Universe and their connection to massive galaxy formation. Unfortunately, extremely luminous quasars at high redshift are very rare objects. Only wide area surveys have a chance to constrain their population. The Sloan Digital Sky Survey (SDSS) nd the Baryon Oscillation Spectroscopic Survey (BOSS) have so far provided the most widely adopted measurements of the type I quasar luminosity function (QLF) at z>3. However, a careful re-examination of the SDSS quasar sample revealed that the SDSS quasar selection is in fact missing a significant fraction of $z~3$ quasars at the brightest end.We have identified the purely optical color selection of SDSS, where quasars at these redshifts are strongly contaminated by late-type dwarfs, and the spectroscopic incompleteness of the SDSS footprint as the main reasons. Therefore we have designed the Extremely Luminous Quasar Survey (ELQS), based on a novel near-infrared JKW2 color cut using WISE AllWISE and 2MASS all-sky photometry, to yield high completeness for very bright (i < 18.0) quasars in the redshift range of 2.8<= z<=5.0. It effectively uses Random Forest machine-learning algorithms on SDSS and WISE photometry for quasar-star classification and photometric redshift estimation.The ELQS is spectroscopically following up ~230 new quasar candidates in an area of ~12000 deg2 in the SDSS footprint, to obtain a well-defined and complete quasar sample for an accurate measurement of the bright-end quasar luminosity function (QLF) at 2.8<= z<=5.0. So far the ELQS has identified 75 bright new quasars in this redshift range and observations of the fall sky will continue until the end of the year. At the AAS winter meeting we will present the full spectroscopic results of the survey, including a re-estimation and extension of the high-z QLF toward higher luminosities.

  20. High-Risk Premenopausal Luminal A Breast Cancer Patients Derive no Benefit from Adjuvant Cyclophosphamide-based Chemotherapy: Results from the DBCG77B Clinical Trial.

    Science.gov (United States)

    Nielsen, Torsten O; Jensen, Maj-Brit; Burugu, Samantha; Gao, Dongxia; Jørgensen, Charlotte L Tykjaer; Balslev, Eva; Ejlertsen, Bent

    2017-02-15

    Purpose: Luminal A breast cancers have better prognosis than other molecular subtypes. Luminal A cancers may also be insensitive to adjuvant chemotherapy, although there is little high-level evidence to confirm this concept. The primary hypothesis in this formal prospective-retrospective analysis was to assess interaction between subtype (Luminal A vs. other) and treatment (chemotherapy vs. not) for the primary endpoint (10-year invasive disease-free survival) of a breast cancer trial randomizing women to adjuvant chemotherapy, analyzed in multivariate Cox proportional hazards models using the Wald interaction test. Experimental Design: The Danish Breast Cancer Cooperative Group 77B clinical trial randomized 1,072 premenopausal women to no systematic treatment (control), levamisole, cyclophosphamide, or cyclophosphamide-methotrexate-fluorouracil arms. All arms included radiotherapy but no endocrine therapy. Researchers with no access to clinical data performed intrinsic subtype analysis on tissue microarrays using published immunohistochemical methods based on estrogen receptor, progesterone receptor, HER2, Ki67, and basal markers. Results: Patients ( n = 709) had tissue available; chemotherapy benefit in these patients was similar to the original trial (HR, 0.56). Immunohistochemistry classified 165 as Luminal A, 319 Luminal B, 58 HER2-enriched, and 82 core basal (among 91 triple-negative). Patients with Luminal A breast tumors did not benefit from chemotherapy [HR, 1.06; 95% confidence interval (CI), 0.53-2.14; P = 0.86], whereas patients with non-luminal A subtypes did (HR, 0.50; 95% CI, 0.38-0.66; P benefit from adjuvant cyclophosphamide-based chemotherapy. Clin Cancer Res; 23(4); 946-53. ©2016 AACR . ©2016 American Association for Cancer Research.

  1. Contribution to the study of luminous sources for uranium isotope measurements by emission spectrometry; Contribution a l'etude de sources lumineuses destinees au dosage isotopique de l'uranium par spectrometrie d'emission

    Energy Technology Data Exchange (ETDEWEB)

    Leichnam, J P; Capitini, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    After a brief summary of results obtained with different hollow cathode luminous sources, the reasons for which they cannot be more widely used are given: an insufficient luminosity when uranium oxides are used in the cathode hollow; the large amount of sample required when it is metallic; the impossibility of effecting a chemical purification of the sample. Electrode-less discharge tubes excited by high frequency whose qualities (luminosity, stability, rapidity of preparation starting from small amounts of sample in various chemical forms, in particular iron) satisfy the conditions laid down for the measurement of uranium 235 by interferometry are used. Tho production process for such lamps is given together with the method of excitation. Examples of recordings obtained with an interferometer of the 'HYPEAC' type and a small grating spectrometer give an idea of the spectral qualities of these sources. (authors) [French] Apres avoir rappele les resultats obtenus avec differentes sources de lumiere a cathode creuse, on explique les raisons qui limitent leur emploi: brillance trop faible lorsque les oxydes d'uranium sont utilises dans le trou cathodique; trop grande quantite d'echantillon necessaire lorsque celui-ci est sous forme metallique; impossibilite de purifier chimiquement l'echantillon. On a employe des tubes a decharge sans electrode excitee par haute frequence, dont les qualites (brillance, stabilite, rapidite de preparation a partir de faibles quantites d'echantillon se presentant sous des formes chimiques diverses, elimination des impuretes chimiques, en particulier du fer) repondent aux conditions imposees pour le dosage isotopique de l'uranium 235 par interferometrie. On decrit le mode operatoire de fabrication de telles lampes et on rappelle le systeme d'excitation. Des exemples d'enregistrement, obtenus avec un appareil interferometrique 'HYPEAC' et un petit spectrometre a reseau, donnent une idee des qualites spectrales de ces sources. (auteurs)

  2. Luminance requirements for lighted signage

    Science.gov (United States)

    Freyssinier, Jean Paul; Narendran, Nadarajah; Bullough, John D.

    2006-08-01

    Light-emitting diode (LED) technology is presently targeted to displace traditional light sources in backlighted signage. The literature shows that brightness and contrast are perhaps the two most important elements of a sign that determine its attention-getting capabilities and its legibility. Presently, there are no luminance standards for signage, and the practice of developing brighter signs to compete with signs in adjacent businesses is becoming more commonplace. Sign luminances in such cases may far exceed what people usually need for identifying and reading a sign. Furthermore, the practice of higher sign luminance than needed has many negative consequences, including higher energy use and light pollution. To move toward development of a recommendation for lighted signage, several laboratory human factors evaluations were conducted. A scale model of a storefront was used to present human subjects with a typical red channel-letter sign at luminances ranging from 8 cd/m2 to 1512 cd/m2 under four background luminances typical of nighttime outdoor and daytime inside-mall conditions (1, 100, 300, 1000 cd/m2), from three scaled viewing distances (30, 60, 340 ft), and either in isolation or adjacent to two similar signs. Subjects rated the brightness, acceptability, and ease of reading of the test sign for each combination of sign and background luminances and scaled viewing distances.

  3. Luminance-based specular gloss characterization.

    Science.gov (United States)

    Leloup, Frédéric B; Pointer, Michael R; Dutré, Philip; Hanselaer, Peter

    2011-06-01

    Gloss is a feature of visual appearance that arises from the directionally selective reflection of light incident on a surface. Especially when a distinct reflected image is perceptible, the luminance distribution of the illumination scene above the sample can strongly influence the gloss perception. For this reason, industrial glossmeters do not provide a satisfactory gloss estimation of high-gloss surfaces. In this study, the influence of the conditions of illumination on specular gloss perception was examined through a magnitude estimation experiment in which 10 observers took part. A light booth with two light sources was utilized: the mirror image of only one source being visible in reflection by the observer. The luminance of both the reflected image and the adjacent sample surface could be independently varied by separate adjustment of the intensity of the two light sources. A psychophysical scaling function was derived, relating the visual gloss estimations to the measured luminance of both the reflected image and the off-specular sample background. The generalization error of the model was estimated through a validation experiment performed by 10 other observers. In result, a metric including both surface and illumination properties is provided. Based on this metric, improved gloss evaluation methods and instruments could be developed.

  4. An extremely luminous and variable ultraluminous X-ray source in the outskirts of Circinus observed with NuSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Walton, D. J.; Fuerst, F.; Harrison, F.; Stern, D.; Grefenstette, B. W.; Madsen, K. K.; Rana, V. [Space Radiation Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States); Bachetti, M.; Barret, D.; Webb, N. A. [Universite de Toulouse, UPS-OMP, IRAP, Toulouse (France); Bauer, F. [Instituto de Astrofísica, Facultad de Física, Pontificia Universidad Católica de Chile, 306, Santiago 22 (Chile); Boggs, S. E.; Craig, W. W. [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Christensen, F. E. [DTU Space, National Space Institute, Technical University of Denmark, Elektrovej 327, DK-2800 Lyngby (Denmark); Fabian, A. C. [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); Hailey, C. J. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Miller, J. M. [Department of Astronomy, University of Michigan, 500 Church Street, Ann Arbor, MI 48109-1042 (United States); Ptak, A.; Zhang, W. W. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2013-12-20

    Following a serendipitous detection with the Nuclear Spectroscopic Telescope Array (NuSTAR), we present a multi-epoch spectral and temporal analysis of an extreme ultraluminous X-ray source (ULX) located in the outskirts of the Circinus galaxy, hereafter Circinus ULX5, including coordinated XMM-Newton+NuSTAR follow-up observations. The NuSTAR data presented here represent one of the first instances of a ULX reliably detected at hard (E > 10 keV) X-rays. Circinus ULX5 is variable on long time scales by at least a factor of ∼5 in flux, and was caught in a historically bright state during our 2013 observations (0.3-30.0 keV luminosity of 1.6 × 10{sup 40} erg s{sup –1}). During this epoch, the source displayed a curved 3-10 keV spectrum, broadly similar to other bright ULXs. Although pure thermal models result in a high energy excess in the NuSTAR data, this excess is too weak to be modeled with the disk reflection interpretation previously proposed to explain the 3-10 keV curvature in other ULXs. In addition to flux variability, clear spectral variability is also observed. While in many cases the interpretation of spectral components in ULXs is uncertain, the spectral and temporal properties of all the high quality data sets currently available strongly support a simple disk-corona model reminiscent of that invoked for Galactic binaries, with the accretion disk becoming more prominent as the luminosity increases. However, although the disk temperature and luminosity are well correlated across all time scales currently probed, the observed luminosity follows L∝T {sup 1.70±0.17}, flatter than expected for simple blackbody radiation. The spectral variability displayed here is highly reminiscent of that observed from known Galactic black hole binaries (BHBs) at high luminosities. This comparison implies a black hole mass of ∼90 M {sub ☉} for Circinus ULX5. However, given the diverse behavior observed from Galactic BHB accretion disks, this mass estimate is

  5. High average power supercontinuum sources

    Indian Academy of Sciences (India)

    The physical mechanisms and basic experimental techniques for the creation of high average spectral power supercontinuum sources is briefly reviewed. We focus on the use of high-power ytterbium-doped fibre lasers as pump sources, and the use of highly nonlinear photonic crystal fibres as the nonlinear medium.

  6. High-mobility group box 1 released by autophagic cancer-associated fibroblasts maintains the stemness of luminal breast cancer cells.

    Science.gov (United States)

    Zhao, Xi-Long; Lin, Yong; Jiang, Jun; Tang, Zhuo; Yang, Shuai; Lu, Lu; Liang, Yan; Liu, Xue; Tan, Jiao; Hu, Xu-Gang; Niu, Qin; Fu, Wen-Juan; Yan, Ze-Xuan; Guo, De-Yu; Ping, Yi-Fang; Wang, Ji Ming; Zhang, Xia; Kung, Hsiang-Fu; Bian, Xiu-Wu; Yao, Xiao-Hong

    2017-11-01

    Cancer stem cells/cancer-initiating cells (CICs) and their microenvironmental niche play a vital role in malignant tumour recurrence and metastasis. Cancer-associated fibroblasts (CAFs) are major components of the niche of breast cancer-initiating cells (BCICs), and their interactions may profoundly affect breast cancer progression. Autophagy has been considered to be a critical process for CIC maintenance, but whether it is involved in the cross-talk between CAFs and CICs to affect tumourigenesis and pathological significance has not been determined. In this study, we found that the presence of CAFs containing high levels of microtubule-associated protein 1 light chain 3 (LC3II), a marker of autophagosomes, was associated with more aggressive luminal human breast cancer. CAFs in human luminal breast cancer tissues with high autophagy activity enriched BCICs with increased tumourigenicity. Mechanistically, autophagic CAFs released high-mobility group box 1 (HMGB1), which activated its receptor, Toll-like receptor (TLR) 4, expressed by luminal breast cancer cells, to enhance their stemness and tumourigenicity. Furthermore, immunohistochemistry of 180 luminal breast cancers revealed that high LC3II/TLR4 levels predicted an increased relapse rate and a poorer prognosis. Our findings demonstrate that autophagic CAFs play a critical role in promoting the progression of luminal breast cancer through an HMGB1-TLR4 axis, and that both autophagy in CAFs and TLR4 on breast cancer cells constitute potential therapeutic targets. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.

  7. High brightness ion source

    International Nuclear Information System (INIS)

    Dreyfus, R.W.; Hodgson, R.T.

    1975-01-01

    A high brightness ion beam is obtainable by using lasers to excite atoms or molecules from the ground state to an ionized state in increments, rather than in one step. The spectroscopic resonances of the atom or molecule are used so that relatively long wavelength, low power lasers can be used to obtain such ion beam

  8. Feeding high fibre diets changes luminal environment and morphology in the intestine of sows

    DEFF Research Database (Denmark)

    Serena, Anja; Hedemann, Mette Skou; Bach Knudsen, Knud Erik

    2007-01-01

    -products (sugar beet pulp, potato pulp, pectin residue, pea hull, brewer's spent grain, and seed residue). The diets were fed for a four-week period to 12 sows (4 for each diet). Sows were stunned 4 h post-feeding, and digesta and tissue samples were collected from various parts of the small and large intestines......Sows were fed three diets varying in type and level of dietary fibre (DF). The low fibre diet (LF; 17% DF) was based on wheat and barley. In the two high DF diets (HF1, high in soluble DF and HF2, high in insoluble DF;  44% DF), the cereal part of the diet was substituted with different co....... The carbohydrate load to the large intestine was 538-539 g/d when feeding the high DF diets and 190 g/d when feeding diet LF. Feeding sows the high DF diet containing large proportion of soluble DF resulted in a lower dry matter content of digesta (23 contra 28%), a higher tissue weight (2.9 contra 2.0 kg...

  9. High luminance LCD projection TV, 40ZIP; Kokido ekisho projection terebi 40ZIP

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    A 40 type LCD projection TV was commercialized which utilized the characteristics of a `large screen`, `saved space` and `light weight` incident to an LCD projection system and which succeeded `a television benign to people`, the concept of a flat wide television FACE{sub TM}. The main features are as follows:(1) A bright-in-every-corner and high-definition picture realized by employing a 2.7 type low temperature polysilicon LCD panel, high performance optical unit, wide angle of visibility, and high contrast screen. (2) A slim design for a 40 type large screen (compared with conventional models at Toshiba) having a depth comparable to that of 14 type and a mass equivalent to that of 25 type.(3) A PC input terminal most suitable for presentation. (translated by NEDO)

  10. Study of luminous spots observed on metallic surfaces subjected to high RF fields

    International Nuclear Information System (INIS)

    Junquera, T.; Maissa, S.; Fouaidy, M.; Le Goff, A.; Bonin, B.; Luong, M.; Safa, H.; Tan, J.

    1995-01-01

    The performance of high gradient superconducting RF cavities for electron accelerators is mainly limited by field emission. Major improvements have been recently obtained using different surface conditioning techniques confirming the involvement of metallic particles in field emission enhancement. Results obtained with an optical apparatus attached to an RF copper cavity equipped with a removable sample which is subjected to high RF fields are presented. Stable light spots are observed on the sample surface and their intensities and optical spectra are measured as a function of the surface electric field. The total emitted current is simultaneously measured by an isolated hollow electrode facing the sample. (K.A.)

  11. Ionized Gas Kinematics around an Ultra-luminous X-Ray Source in NGC 5252: Additional Evidence for an Off-nuclear AGN

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Minjin [Korea Astronomy and Space Science Institute, Daejeon 305-348 (Korea, Republic of); Ho, Luis C. [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China); Im, Myungshin [Center for the Exploration of the Origin of the Universe (CEOU), Astronomy Program, Department of Physics and Astronomy, Seoul National University, 599 Gwanak-ro, Gwanak-gu, Seoul, 151-742 (Korea, Republic of)

    2017-08-01

    The Seyfert 2 galaxy NGC 5252 contains a recently identified ultra-luminous X-ray (ULX) source that has been suggested to be a possible candidate off-nuclear low-mass active galactic nucleus. We present follow-up optical integral-field unit observations obtained using Gemini Multi-Object Spectrographs on the Gemini-North telescope. In addition to confirming that the ionized gas in the vicinity of the ULX is kinematically associated with NGC 5252, the new observations reveal ordered motions consistent with rotation around the ULX. The close coincidence of the excitation source of the line-emitting gas with the position of the ULX further suggests that ULX itself is directly responsible for the ionization of the gas. The spatially resolved measurements of [N ii] λ 6584/H α surrounding the ULX indicate a low gas-phase metallicity, consistent with those of other known low-mass active galaxies but not that of its more massive host galaxy. These findings strengthen the proposition that the ULX is not a background source but rather that it is the nucleus of a small, low-mass galaxy accreted by NGC 5252.

  12. High current density ion source

    International Nuclear Information System (INIS)

    King, H.J.

    1977-01-01

    A high-current-density ion source with high total current is achieved by individually directing the beamlets from an electron bombardment ion source through screen and accelerator electrodes. The openings in these screen and accelerator electrodes are oriented and positioned to direct the individual beamlets substantially toward a focus point. 3 figures, 1 table

  13. Unseen Progenitors of Luminous High- z Quasars in the R {sub h} = ct Universe

    Energy Technology Data Exchange (ETDEWEB)

    Fatuzzo, Marco [Physics Department, Xavier University, Cincinnati, OH 45207 (United States); Melia, Fulvio, E-mail: fatuzzo@xavier.edu, E-mail: fmelia@email.arizona.edu [Department of Physics, The Applied Math Program, and Department of Astronomy, The University of Arizona, AZ 85721 (United States)

    2017-09-10

    Quasars at high redshift provide direct information on the mass growth of supermassive black holes (SMBHs) and, in turn, yield important clues about how the universe evolved since the first (Pop III) stars started forming. Yet even basic questions regarding the seeds of these objects and their growth mechanism remain unanswered. The anticipated launch of eROSITA and ATHENA is expected to facilitate observations of high-redshift quasars needed to resolve these issues. In this paper, we compare accretion-based SMBH growth in the concordance ΛCDM model with that in the alternative Friedmann–Robertson–Walker cosmology known as the R {sub h} = ct universe. Previous work has shown that the timeline predicted by the latter can account for the origin and growth of the ≳10{sup 9} M {sub ⊙} highest redshift quasars better than that of the standard model. Here, we significantly advance this comparison by determining the soft X-ray flux that would be observed for Eddington-limited accretion growth as a function of redshift in both cosmologies. Our results indicate that a clear difference emerges between the two in terms of the number of detectable quasars at redshift z ≳ 7, raising the expectation that the next decade will provide the observational data needed to discriminate between these two models based on the number of detected high-redshift quasar progenitors. For example, while the upcoming ATHENA mission is expected to detect ∼0.16 (i.e., essentially zero) quasars at z ∼ 7 in R {sub h} = ct , it should detect ∼160 in ΛCDM—a quantitatively compelling difference.

  14. An extremely luminous and variable ultraluminous x-ray source in the outskirts of circinus observed with NuSTAR

    DEFF Research Database (Denmark)

    Walton, D. J.; Fuerst, F.; Harrison, F.

    2013-01-01

    Following a serendipitous detection with the Nuclear Spectroscopic Telescope Array (NuSTAR), we present a multi-epoch spectral and temporal analysis of an extreme ultraluminous X-ray source (ULX) located in the outskirts of the Circinus galaxy, hereafter Circinus ULX5, including coordinated XMM-N...

  15. Facile and Low-Temperature Fabrication of Thermochromic Cr2O3/VO2 Smart Coatings: Enhanced Solar Modulation Ability, High Luminous Transmittance and UV-Shielding Function.

    Science.gov (United States)

    Chang, Tianci; Cao, Xun; Li, Ning; Long, Shiwei; Gao, Xiang; Dedon, Liv R; Sun, Guangyao; Luo, Hongjie; Jin, Ping

    2017-08-09

    In the pursuit of energy efficient materials, vanadium dioxide (VO 2 ) based smart coatings have gained much attention in recent years. For smart window applications, VO 2 thin films should be fabricated at low temperature to reduce the cost in commercial fabrication and solve compatibility problems. Meanwhile, thermochromic performance with high luminous transmittance and solar modulation ability, as well as effective UV shielding function has become the most important developing strategy for ideal smart windows. In this work, facile Cr 2 O 3 /VO 2 bilayer coatings on quartz glasses were designed and fabricated by magnetron sputtering at low temperatures ranging from 250 to 350 °C as compared with typical high growth temperatures (>450 °C). The bottom Cr 2 O 3 layer not only provides a structural template for the growth of VO 2 (R), but also serves as an antireflection layer for improving the luminous transmittance. It was found that the deposition of Cr 2 O 3 layer resulted in a dramatic enhancement of the solar modulation ability (56.4%) and improvement of luminous transmittance (26.4%) when compared to single-layer VO 2 coating. According to optical measurements, the Cr 2 O 3 /VO 2 bilayer structure exhibits excellent optical performances with an enhanced solar modulation ability (ΔT sol = 12.2%) and a high luminous transmittance (T lum,lt = 46.0%), which makes a good balance between ΔT sol and T lum for smart windows applications. As for UV-shielding properties, more than 95.8% UV radiation (250-400 nm) can be blocked out by the Cr 2 O 3 /VO 2 structure. In addition, the visualized energy-efficient effect was modeled by heating a beaker of water using infrared imaging method with/without a Cr 2 O 3 /VO 2 coating glass.

  16. Research on the calibration methods of the luminance parameter of radiation luminance meters

    Science.gov (United States)

    Cheng, Weihai; Huang, Biyong; Lin, Fangsheng; Li, Tiecheng; Yin, Dejin; Lai, Lei

    2017-10-01

    This paper introduces standard diffusion reflection white plate method and integrating sphere standard luminance source method to calibrate the luminance parameter. The paper compares the effects of calibration results by using these two methods through principle analysis and experimental verification. After using two methods to calibrate the same radiation luminance meter, the data obtained verifies the testing results of the two methods are both reliable. The results show that the display value using standard white plate method has fewer errors and better reproducibility. However, standard luminance source method is more convenient and suitable for on-site calibration. Moreover, standard luminance source method has wider range and can test the linear performance of the instruments.

  17. Experimental study on the luminous radiation associated to the field emission of samples submitted to high RF fields

    International Nuclear Information System (INIS)

    Maissa, S.; Junquera, T.; Fouaidy, M.; Le Goff, A.; Luong, M.; Tan, J.; Bonin, B.; Safa, H.

    1996-01-01

    Nowadays the accelerating gradient of the RF cavities is limited by the strong field emission (FE) of electrons stemming from the metallic walls. Previous experiments evidenced luminous radiations associated with electron emission on cathodes subjected to intense DC electric field. These observations led these authors to propose new theoretical models of the field emission phenomenon. The presented experimental study extends these previous DC works to the RF case. A special copper RF cavity has been developed equipped with an optical window and a removable sample. It has been designed for measuring both electron current and luminous radiation emitted by the sample, subjected to maximum RF electric field. The optical apparatus attached to the cavity permits to characterize the radiation in terms of intensity, glowing duration and spectral distribution. The results concerning different niobium or copper samples, whom top was either scratched or intentionally contaminated with metallic or dielectric particles are summarized. (author)

  18. Experimental study on the luminous radiation associated to the field emission of samples submitted to high RF fields

    International Nuclear Information System (INIS)

    Maissa, S.; Junquera, T.; Fouaidy, M.; Le Goff, A.; Luong, M.; Tan, J.; Bonin, B.; Safa, H.

    1996-01-01

    The accelerating gradient of the RF cavities is limited by the strong field emission (FE) of electrons stemming from the metallic walls. Previous experiments evidenced luminous radiations associated with electron emission of cathodes subjected to intense DC electric field. These observations invoked the proposal of new theoretical models of the field emission phenomenon. This experimental study extends the previous DC works to the RF case. A special copper RF cavity has been developed equipped with an optical window and a removable sample. It has been designed for measuring both electron current and luminous radiation emitted by the sample, subjected to maximum RF electric field. The optical apparatus attached to the cavity permits to characterize the radiation in terms of intensity, glowing duration and spectral distribution. The results concerning different niobium or copper samples, whom top was either scratched or intentionally contaminated with metallic or dielectric particles are summarized. (author)

  19. Colon luminal content and epithelial cell morphology are markedly modified in rats fed with a high-protein diet.

    Science.gov (United States)

    Andriamihaja, Mireille; Davila, Anne-Marie; Eklou-Lawson, Mamy; Petit, Nathalie; Delpal, Serge; Allek, Fadhila; Blais, Anne; Delteil, Corine; Tomé, Daniel; Blachier, François

    2010-11-01

    Hyperproteic diets are used in human nutrition to obtain body weight reduction. Although increased protein ingestion results in an increased transfer of proteins from the small to the large intestine, there is little information on the consequences of the use of such diets on the composition of large intestine content and on epithelial cell morphology and metabolism. Rats were fed for 15 days with either a normoproteic (NP, 14% protein) or a hyperproteic isocaloric diet (HP, 53% protein), and absorptive colonocytes were observed by electron microscopy or isolated for enzyme activity studies. The colonic luminal content was recovered for biochemical analysis. Absorbing colonocytes were characterized by a 1.7-fold reduction in the height of the brush-border membranes (P = 0.0001) after HP diet consumption when compared with NP. This coincided in the whole colon content of HP animals with a 1.8-fold higher mass content (P = 0.0020), a 2.2-fold higher water content (P = 0.0240), a 5.2-fold higher protease activity (P = 0.0104), a 5.5-fold higher ammonia content (P = 0.0008), and a more than twofold higher propionate, valerate, isobutyrate, and isovalerate content (P hyperproteic diet ingestion causes marked changes both in the luminal environment of colonocytes and in the characteristics of these cells, demonstrating that hyperproteic diet interferes with colonocyte metabolism and morphology. Possible causal relationships between energy metabolism, reduced height of colonocyte brush-border membranes, and reduced water absorption are discussed.

  20. The most luminous heavily obscured quasars have a high merger fraction: morphological study of wise -selected hot dust-obscured galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Lulu; Gao, Ying; Zhang, Dandan; Jiang, Xiaoming; Wu, Qiaoqian; Yang, Jun; Li, Zhao [Shandong Provincial Key Lab of Optical Astronomy and Solar-Terrestrial Environment, Institute of Space Science, Shandong University, Weihai 264209 (China); Han, Yunkun [Yunnan Observatories, Chinese Academy of Sciences, Kunming 650011 (China); Fang, Guanwen, E-mail: llfan@sdu.edu.cn, E-mail: hanyk@ynao.ac.cn [Institute for Astronomy and History of Science and Technology, Dali University, Dali 671003 (China)

    2016-05-10

    Previous studies have shown that Wide-field Infrared Survey Explorer -selected hyperluminous, hot dust-obscured galaxies (Hot DOGs) are powered by highly dust-obscured, possibly Compton-thick active galactic nuclei (AGNs). High obscuration provides us a good chance to study the host morphology of the most luminous AGNs directly. We analyze the host morphology of 18 Hot DOGs at z ∼ 3 using Hubble Space Telescope /WFC3 imaging. We find that Hot DOGs have a high merger fraction (62 ± 14%). By fitting the surface brightness profiles, we find that the distribution of Sérsic indices in our Hot DOG sample peaks around 2, which suggests that most Hot DOGs have transforming morphologies. We also derive the AGN bolometric luminosity (∼10{sup 14} L {sub ⊙}) of our Hot DOG sample by using IR spectral energy distributions decomposition. The derived merger fraction and AGN bolometric luminosity relation is well consistent with the variability-based model prediction. Both the high merger fraction in an IR-luminous AGN sample and relatively low merger fraction in a UV/optical-selected, unobscured AGN sample can be expected in the merger-driven evolutionary model. Finally, we conclude that Hot DOGs are merger-driven and may represent a transit phase during the evolution of massive galaxies, transforming from the dusty starburst-dominated phase to the unobscured QSO phase.

  1. High Intensity Source Laboratory (HISL)

    International Nuclear Information System (INIS)

    1992-01-01

    The High Intensity Source Laboratory (HISL) is a laboratory facility operated for the US Department of Energy (DOE) by EG ampersand G, Energy Measurements (EG ampersand G/EM). This document is intended as an overview -- primarily for external users -- of the general purposes and capabilities of HISL; numerous technical details are beyond its scope. Moreover, systems at HISL are added, deleted, and modified to suit current needs, and upgraded with continuing development. Consequently, interested parties are invited to contact the HISL manager for detailed, current, technical, and administrative information. The HISL develops and operates pulsed radiation sources with energies, intensities, and pulse widths appropriate for several applications. Principal among these are development, characterization, and calibration of various high-bandwidth radiation detectors and diagnostic systems. Hardness/vulnerability of electronic or other sensitive components to radiation is also tested. In this connection, source development generally focuses on attending (1) the highest possible intensities with (2) reasonably short pulse widths and (3) comprehensive output characterization

  2. The Overdense Environments of WISE-Selected, Ultra-Luminous, High-Redshift AGN in the Submillimeter

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Suzy F., E-mail: suzy.jones@chalmers.se [Department of Space, Earth, and Environment, Chalmers University of Technology, Onsala Space Observatory, Onsala (Sweden)

    2017-11-21

    The environments around WISE-selected hot dust obscured galaxies (Hot DOGs) and WISE/radio-selected active galactic nuclei (AGNs) at average redshifts of z = 2.7 and z = 1.7, respectively, were found to have overdensities of companion Submillimeter-selected sources. The overdensities were of ~2–3 and ~5–6, respectively, compared with blank field submm surveys. The space densities in both samples were found to be overdense compared to normal star-forming galaxies and Submillimeter galaxies (SMGs). All of the companion sources have consistent mid-IR colors and mid-IR to submm ratios to SMGs. Monte Carlo simulations show no angular correlation, which could indicate protoclusters on scales larger than the SCUBA-2 1.5 arcmin scale maps. WISE-selected AGNs appear to be good indicators of overdense areas of active galaxies at high redshift.

  3. High power microwave source development

    Science.gov (United States)

    Benford, James N.; Miller, Gabriel; Potter, Seth; Ashby, Steve; Smith, Richard R.

    1995-05-01

    The requirements of this project have been to: (1) improve and expand the sources available in the facility for testing purposes and (2) perform specific tasks under direction of the Defense Nuclear Agency about the applications of high power microwaves (HPM). In this project the HPM application was power beaming. The requirements of this program were met in the following way: (1) We demonstrated that a compact linear induction accelerator can drive HPM sources at repetition rates in excess of 100 HZ at peak microwave powers of a GW. This was done for the relativistic magnetron. Since the conclusion of this contract such specifications have also been demonstrated for the relativistic klystron under Ballistic Missile Defense Organization funding. (2) We demonstrated an L band relativistic magnetron. This device has been used both on our single pulse machines, CAMEL and CAMEL X, and the repetitive system CLIA. (3) We demonstrated that phase locking of sources together in large numbers is a feasible technology and showed the generation of multigigawatt S-band radiation in an array of relativistic magnetrons.

  4. Report on the achievements in fiscal 1999 of research and development of a femto-second technology. Research and developing of a electric power generation facility monitoring system utilizing high-luminance X-ray pulses; 1999 nendo femto byo technology no kenkyu kaihatsu seika hokokusho. Kokido X sen riyo hatsuden shisetsu monitoring system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Researches have been made with an objective to generate femto-second high-luminance X-ray pulses by using interactions between femto-second light pulses and high-density electron ray pulses, and to develop a technology to use the above pulses to measure objects moving at high speeds. This paper reports the achievements in fiscal 1999. In research and development of the ultra short light/electron ray pulse generating and controlling technology, totally solid laser was used as an excitation source for a mode synchronous laser transmitter. A high-accuracy moving stage driven by piezo elements and motor was used to actively control the resonator length by using the RF reference signals, wherein time fluctuation was reduced down to 100 fs level. Design and fabrication were performed on an electron ray accelerator and an electron ray transporter of the electron ray source system for Compton X-ray. Electron energy of 12 MeV and electric charge of 1 nC were achieved in an electron beam acceleration test. In the research and development of a femto-second high-luminance X-ray pulse generating technology, design and fabrication were carried out on a Compton collision chamber that can generate X-ray pulses with high luminance. (NEDO)

  5. EVOLUTION OF THE MOST LUMINOUS DUSTY GALAXIES

    International Nuclear Information System (INIS)

    Weedman, Daniel W.; Houck, James R.

    2009-01-01

    A summary of mid-infrared continuum luminosities arising from dust is given for very luminous galaxies, L IR > 10 12 L sun , with 0.005 0.7 in the 9.7 μm silicate absorption feature (i.e., half of the continuum is absorbed) and having equivalent width of the 6.2 μm polycyclic aromatic hydrocarbon feature ν (8 μm) for the most luminous obscured AGNs is found to scale as (1+z) 2.6 to z = 2.8. For unobscured AGNs, the scaling with redshift is similar, but luminosities νL ν (8 μm) are approximately three times greater for the most luminous sources. Using both obscured and unobscured AGNs having total infrared fluxes from the Infrared Astronomical Satellite, empirical relations are found between νL ν (8 μm) and L IR . Combining these relations with the redshift scaling of luminosity, we conclude that the total infrared luminosities for the most luminous obscured AGNs, L IR (AGN obscured ) in L sun , scale as log L IR (AGN obscured ) = 12.3 ± 0.25 + 2.6(±0.3)log(1+z), and for the most luminous unobscured AGNs, scale as log L IR (AGN1) = 12.6(±0.15) + 2.6(±0.3)log(1+z). We previously determined that the most luminous starbursts scale as log L IR (SB) = 11.8 ± 0.3 + 2.5(±0.3)log(1+z), indicating that the most luminous AGNs are about 10 times more luminous than the most luminous starbursts. Results are consistent with obscured and unobscured AGNs having the same total luminosities with differences arising only from orientation, such that the obscured AGNs are observed through very dusty clouds which extinct about 50% of the intrinsic luminosity at 8 μm. Extrapolations of observable f ν (24 μm) to z = 6 are made using evolution results for these luminous sources. Both obscured and unobscured AGNs should be detected to z ∼ 6 by Spitzer surveys with f ν (24 μm) > 0.3 mJy, even without luminosity evolution for z > 2.5. By contrast, the most luminous starbursts cannot be detected for z > 3, even if luminosity evolution continues beyond z = 2.5.

  6. PALBOCICLIB IN COMBINATION WITH HORMONE THERAPY FOR LUMINAL HER2-NEGATIVE METASTATIC BREAST CANCER: NEW HIGHLY EFFECTIVE STRATEGY OF DRUG TREATMENT

    Directory of Open Access Journals (Sweden)

    E. V. Artamonova

    2017-01-01

    Full Text Available The review considers a new oral targeted drug palbociclib and its place in treatment of luminal (estrogen receptor-positive HER2– metastatic breast cancer. The results of randomized clinical trials have shown that inclusion of palbociclib in various hormone therapy regimens for treatment of HER2– metastatic breast cancer with expression of estrogen receptors allows to significantly improve clinical outcomes and increase survival, objective response rate and its duration, as well as clinical benefit rate (CBR. Addition of palbociclib to letrozole in the 1st line hormone therapy or to fulvestrant in patients with progression at/after previous endocrine therapy increased progression-free survival in all groups irrespective of clinical characteristics, tumor progression, or expression of molecular markers mediating development of hormone resistance. The main adverse events associated with palbociclib were neutropenia, leukopenia and thrombocytopenia, but overall hematological toxicity was manageable, and the therapy itself was safe. This strategy received a “breakthrough therapy designation” from the experts and combines proven effectiveness and satisfactory tolerability, allows to maintain high quality of life, and should be prescribed to patients with luminal HER2– metastatic breast cancer.

  7. High Intensity Polarized Electron Sources

    International Nuclear Information System (INIS)

    Poelker, Benard; Adderley, Philip; Brittian, Joshua; Clark, J.; Grames, Joseph; Hansknecht, John; McCarter, James; Stutzman, Marcy; Suleiman, Riad; Surles-law, Kenneth

    2008-01-01

    During the 1990s, at numerous facilities world wide, extensive RandD devoted to constructing reliable GaAs photoguns helped ensure successful accelerator-based nuclear and high-energy physics programs using spin polarized electron beams. Today, polarized electron source technology is considered mature, with most GaAs photoguns meeting accelerator and experiment beam specifications in a relatively trouble-free manner. Proposals for new collider facilities however, require electron beams with parameters beyond today's state-of-the-art and serve to renew interest in conducting polarized electron source RandD. And at CEBAF/Jefferson Lab, there is an immediate pressing need to prepare for new experiments that require considerably more beam current than before. One experiment in particular?Q-weak, a parity violation experiment that will look for physics beyond the Standard Model?requires 180 uA average current at polarization >80% for a duration of one year, with run-averaged helicity correlate

  8. High current polarized electron source

    Science.gov (United States)

    Suleiman, R.; Adderley, P.; Grames, J.; Hansknecht, J.; Poelker, M.; Stutzman, M.

    2018-05-01

    Jefferson Lab operates two DC high voltage GaAs photoguns with compact inverted insulators. One photogun provides the polarized electron beam at the Continuous Electron Beam Accelerator Facility (CEBAF) up to 200 µA. The other gun is used for high average current photocathode lifetime studies at a dedicated test facility up to 4 mA of polarized beam and 10 mA of un-polarized beam. GaAs-based photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed facilities that must operate in excess of tens of mA of polarized average current. This contribution describes techniques to maintain good vacuum while delivering high beam currents, and techniques that minimize damage due to ion bombardment, the dominant mechanism that reduces photocathode yield. Advantages of higher DC voltage include reduced space-charge emittance growth and the potential for better photocathode lifetime. Highlights of R&D to improve the performance of polarized electron sources and prolong the lifetime of strained-superlattice GaAs are presented.

  9. Mercury-free electrodeless discharge lamp: effect of xenon pressure and plasma parameters on luminance

    International Nuclear Information System (INIS)

    Nazri Dagang Ahmad; Kondo, Akira; Motomura, Hideki; Jinno, Masafumi

    2009-01-01

    Since there is much concern about environmental preservation, the authors have paid attention to the uses of mercury in lighting application. They have focused on the application of the xenon low-pressure inductively coupled plasma (ICP) discharge in developing cylindrical type mercury-free light sources. ICP can be operated at low filling gas pressures and demonstrates significant potential in producing high density plasma. Xenon pressure was varied from 0.1 to 100 Torr and the lamp luminance was measured. The gas pressure dependence shows an increase in luminance at pressures below 1 Torr. In order to clarify this behaviour, measurement of plasma parameters was carried out using the double probe method and its relation to lamp luminance is discussed. As the gas pressure is decreased (from 1 to 0.01 Torr), the electron temperature increases while the electron density decreases while at the same time the lamp luminance increases. There are several factors that are believed to contribute to the increase in luminance in the very low pressure region. Increases in luminance are considered to be due to the electron-ion recombination process which brings a strong recombination radiation in continuum in the visible region and also due to the effect of stochastic heating.

  10. HIGH-DENSITY CIRCUMSTELLAR INTERACTION IN THE LUMINOUS TYPE IIn SN 2010jl: THE FIRST 1100 DAYS

    International Nuclear Information System (INIS)

    Fransson, Claes; Ergon, Mattias; Sollerman, Jesper; Challis, Peter J.; Kirshner, Robert P.; Marion, G. H.; Milisavljevic, Dan; Friedman, Andrew S.; Chornock, Ryan; Czekala, Ian; Soderberg, Alicia; Chevalier, Roger A.; France, Kevin; Smith, Nathan; Bufano, Filomena; Kangas, Tuomas; Larsson, Josefin; Mattila, Seppo; Benetti, Stefano

    2014-01-01

    Hubble Space Telescope and ground-based observations of the Type IIn supernova (SN) 2010jl are analyzed, including photometry and spectroscopy in the ultraviolet, optical, and near-IR bands, 26-1128 days after first detection. At maximum, the bolometric luminosity was ∼3 × 10 43 erg s –1 and even at 850 days exceeds 10 42 erg s –1 . A near-IR excess, dominating after 400 days, probably originates in dust in the circumstellar medium (CSM). The total radiated energy is ≳ 6.5 × 10 50 erg, excluding the dust component. The spectral lines can be separated into one broad component that is due to electron scattering and one narrow with expansion velocity ∼100 km s –1 from the CSM. The broad component is initially symmetric around zero velocity but becomes blueshifted after ∼50 days, while remaining symmetric about a shifted centroid velocity. Dust absorption in the ejecta is unlikely to explain the line shifts, and we attribute the shift instead to acceleration by the SN radiation. From the optical lines and the X-ray and dust properties, there is strong evidence for large-scale asymmetries in the CSM. The ultraviolet lines indicate CNO processing in the progenitor, while the optical shows a number of narrow coronal lines excited by the X-rays. The bolometric light curve is consistent with a radiative shock in an r –2 CSM with a mass-loss rate of M-dot ∼0.1  M ⊙ yr −1 . The total mass lost is ≳ 3 M ☉ . These properties are consistent with the SN expanding into a CSM characteristic of a luminous blue variable progenitor with a bipolar geometry. The apparent absence of nuclear processing is attributed to a CSM that is still opaque to electron scattering

  11. HIGH-DENSITY CIRCUMSTELLAR INTERACTION IN THE LUMINOUS TYPE IIn SN 2010jl: THE FIRST 1100 DAYS

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, Claes; Ergon, Mattias; Sollerman, Jesper [Oskar Klein Centre, Department of Astronomy, Stockholm University, AlbaNova, SE-106 91 Stockholm (Sweden); Challis, Peter J.; Kirshner, Robert P.; Marion, G. H.; Milisavljevic, Dan; Friedman, Andrew S.; Chornock, Ryan; Czekala, Ian; Soderberg, Alicia [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Chevalier, Roger A. [Department of Astronomy, University of Virginia, P.O. Box 400325, Charlottesville, VA 22904 (United States); France, Kevin [CASA, University of Colorado, 593UCB Boulder, CO 80309-0593 (United States); Smith, Nathan [Steward Observatory, University of Arizona, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Bufano, Filomena [Departamento de Ciencias Fisicas, Universidad Andres Bello, Avda. Republica 252, Santiago (Chile); Kangas, Tuomas [Tuorla Observatory, University of Turku, Väisäläntie 20 FI-21500 Piikkiö (Finland); Larsson, Josefin [KTH, Department of Physics, and the Oskar Klein Centre, AlbaNova, SE-106 91 Stockholm (Sweden); Mattila, Seppo [Finnish Centre for Astronomy with ESO (FINCA), University of Turku, Väisäläntie 20 FI-21500 Piikkiö (Finland); Benetti, Stefano [INAF-Osservatorio Astronomico di Padova, Vicolo dellOsservatorio 5, I-35122 Padova (Italy)

    2014-12-20

    Hubble Space Telescope and ground-based observations of the Type IIn supernova (SN) 2010jl are analyzed, including photometry and spectroscopy in the ultraviolet, optical, and near-IR bands, 26-1128 days after first detection. At maximum, the bolometric luminosity was ∼3 × 10{sup 43} erg s{sup –1} and even at 850 days exceeds 10{sup 42} erg s{sup –1}. A near-IR excess, dominating after 400 days, probably originates in dust in the circumstellar medium (CSM). The total radiated energy is ≳ 6.5 × 10{sup 50} erg, excluding the dust component. The spectral lines can be separated into one broad component that is due to electron scattering and one narrow with expansion velocity ∼100 km s{sup –1} from the CSM. The broad component is initially symmetric around zero velocity but becomes blueshifted after ∼50 days, while remaining symmetric about a shifted centroid velocity. Dust absorption in the ejecta is unlikely to explain the line shifts, and we attribute the shift instead to acceleration by the SN radiation. From the optical lines and the X-ray and dust properties, there is strong evidence for large-scale asymmetries in the CSM. The ultraviolet lines indicate CNO processing in the progenitor, while the optical shows a number of narrow coronal lines excited by the X-rays. The bolometric light curve is consistent with a radiative shock in an r {sup –2} CSM with a mass-loss rate of M-dot ∼0.1  M{sub ⊙} yr{sup −1}. The total mass lost is ≳ 3 M {sub ☉}. These properties are consistent with the SN expanding into a CSM characteristic of a luminous blue variable progenitor with a bipolar geometry. The apparent absence of nuclear processing is attributed to a CSM that is still opaque to electron scattering.

  12. Rossi X-Ray Timing Explorer Observations of the First Transient Z Source XTE J1701-462: Shedding New Light on Mass Accretion in Luminous Neutron Star X-Ray Binaries

    Science.gov (United States)

    Homan, Jeroen; van der Klis, Michiel; Wijnands, Rudy; Belloni, Tomaso; Fender, Rob; Klein-Wolt, Marc; Casella, Piergiorgio; Méndez, Mariano; Gallo, Elena; Lewin, Walter H. G.; Gehrels, Neil

    2007-02-01

    We report on the first 10 weeks of RXTE observations of the X-ray transient XTE J1701-462 and conclude that it had all the characteristics of the neutron star Z sources, i.e., the brightest persistent neutron star low-mass X-ray binaries. These include the typical Z-shaped tracks traced out in X-ray color diagrams and the variability components detected in the power spectra, such as kHz QPOs and normal and horizontal branch oscillations. XTE J1701-462 is the first transient Z source and provides unique insights into mass accretion rate (m˙) and luminosity dependencies in neutron star X-ray binaries. As its overall luminosity decreased, we observed a switch between two types of Z source behavior, with the branches of the Z track changing their shape and/or orientation. We interpret this as an extreme case of the more moderate long-term changes seen in the persistent Z sources and suggest that they result from changes in m˙. We also suggest that the Cyg-like Z sources (Cyg X-2, GX 5-1, and GX 340+0) are substantially more luminous (>50%) than the Sco-like Z sources (Sco X-1, GX 17+2, and GX 349+2). Adopting a possible explanation for the behavior of kHz QPOs, which involves a prompt as well as a filtered response to changes in m˙, we further propose that changes in m˙ can explain both movement along the Z track and changes in the shape of the Z track. We discuss some consequences of this and consider the possibility that the branches of the Z will smoothly evolve into the branches observed in X-ray color diagrams of the less luminous atoll sources, although not in a way that was previously suggested.

  13. A cosmic web filament revealed in Lyman-α emission around a luminous high-redshift quasar.

    Science.gov (United States)

    Cantalupo, Sebastiano; Arrigoni-Battaia, Fabrizio; Prochaska, J Xavier; Hennawi, Joseph F; Madau, Piero

    2014-02-06

    Simulations of structure formation in the Universe predict that galaxies are embedded in a 'cosmic web', where most baryons reside as rarefied and highly ionized gas. This material has been studied for decades in absorption against background sources, but the sparseness of these inherently one-dimensional probes preclude direct constraints on the three-dimensional morphology of the underlying web. Here we report observations of a cosmic web filament in Lyman-α emission, discovered during a survey for cosmic gas fluorescently illuminated by bright quasars at redshift z ≈ 2.3. With a linear projected size of approximately 460 physical kiloparsecs, the Lyman-α emission surrounding the radio-quiet quasar UM 287 extends well beyond the virial radius of any plausible associated dark-matter halo and therefore traces intergalactic gas. The estimated cold gas mass of the filament from the observed emission-about 10(12.0 ± 0.5)/C(1/2) solar masses, where C is the gas clumping factor-is more than ten times larger than what is typically found in cosmological simulations, suggesting that a population of intergalactic gas clumps with subkiloparsec sizes may be missing in current numerical models.

  14. High efficiency atomic hydrogen source

    International Nuclear Information System (INIS)

    Lagomarsino, V.; Bassi, D.; Bertok, E.; De Paz, M.; Tommasini, F.

    1974-01-01

    This work presents preliminary results of research intended to produce a M.W. discharge atomic hydrogen source with good dissociation at pressures larger than 10 torr. Analysis of the recombination process at these pressures shows that the volume recombination by three body collisions may be more important than wall recombination or loss of atoms by diffusion and flow outside the discharge region

  15. Geometry of illumination, luminance contrast, and gloss perception

    OpenAIRE

    Leloup, Frédéric; Pointer, Michael R.; Dutré, Philip; Hanselaer, Peter

    2010-01-01

    The influence of both the geometry of illumination and luminance contrast on gloss perception has been examined using the method of paired comparison. Six achromatic glass samples having different lightness were illuminated by two light sources. Only one of these light sources was visible in reflection by the observer. By separate adjustment of the intensity of both light sources, the luminance of both the reflected image and the adjacent off-specular surroundings could be individually varied...

  16. High efficiency optoelectronic terahertz sources

    Science.gov (United States)

    Lampin, Jean-François; Peytavit, Emilien; Akalin, Tahsin; Ducournau, G.; Hindle, Francis; Mouret, Gael

    2010-08-01

    We have developed a new generation of optoelectronic large bandwidth terahertz sources based on TEM horn antennas monolithically integrated with several types of photodetectors: low-temperature grown GaAs (LTG-GaAs) planar photoconductors, vertically integrated LTG-GaAs photoconductors on silicon substrate and uni-travelling-carrier photodiodes. Results of pulsed (time-domain) and photomixing (CW, frequency domain) experiments are presented.

  17. Paul Callaghan luminous moments

    CERN Document Server

    Callaghan, Paul

    2013-01-01

    Acknowledged internationally for his ground-breaking scientific research in the field of magnetic resonance, Sir Paul Callaghan was a scientist and visionary with a rare gift for promoting science to a wide audience. He was named New Zealander of the Year in 2011. His death in early 2012 robbed New Zealand of an inspirational leader. Paul Callaghan: Luminous Moments brings together some of his most significant writing. Whether he describes his childhood in Wanganui, reflects on discovering the beauty of science, sets out New Zealand's future potential or discusses the experience of fa

  18. High-intensity sources for light ions

    International Nuclear Information System (INIS)

    Leung, K.N.

    1995-10-01

    The use of the multicusp plasma generator as a source of light ions is described. By employing radio-frequency induction discharge, the performance of the multicusp source is greatly improved, both in lifetime and in high brightness H + and H - beam production. A new technique for generating multiply-charged ions in this type of ion source is also presented

  19. Atto second high harmonic sources

    International Nuclear Information System (INIS)

    Nam, Chang Hee

    2008-01-01

    High harmonic generation is a powerful method to produce attosecond pulses. The high harmonics, emitted from atoms driven by intense femtosecond laser pulses, can from an attosecond pulse train with equally spaced harmonic spectrum or an isolated single attosecond pulse with broad continuum spectrum. Using high power femtosecond laser technology developed at CXRC, we have investigated the spectral and temporal characteristics of high harmonics obtained from gaseous atoms. The spectral structure of harmonics could be manipulated by controlling laser chirp, and continuous tuning of harmonic wavelengths was achieved. For rigorous temporal characterization of attosecond harmonic pulses a cross correlation technique was applied to the photoionization process by harmonic and IR femtosecond pulses and achieved the complete temporal reconstruction of attosecond pulse trains, revealing the detailed temporal structure of the attosecond chirp by material dispersion. The duration of attosecond high harmonic pulses is usually much longer than that of transform limited pulses due to the inherent chirp originating from the harmonic generation process. The attosecond chirp compensation in the harmonic generation medium itself was demonstrated, thereby realizing the generation of near transform limited attosecond pulses. The interference of attosecond electron wave packets, generated from an atom by attosecond harmonic pulses, will be also presented

  20. Planck intermediate results XXXIX. The Planck list of high-redshift source candidates

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Aghanim, N.; Arnaud, M.

    2016-01-01

    on a component-separation procedure using a combination of Planck and IRAS data, has been validated and characterized on numerous simulations, and applied to select the most luminous cold submillimetre sources with spectral energy distributions peaking between 353 and 857 GHz at 5' resolution. A total of 2151......The Planck mission, thanks to its large frequency range and all-sky coverage, has a unique potential for systematically detecting the brightest, and rarest, submillimetre sources on the sky, including distant objects in the high-redshift Universe traced by their dust emission. A novel method, based...... Planck high-z source candidates (the PHZ) have been detected in the cleanest 26% of the sky, with flux density at 545 GHz above 500 mJy. Embedded in the cosmic infrared background close to the confusion limit, these high-z candidates exhibit colder colours than their surroundings, consistent...

  1. High current ion source development at Frankfurt

    Energy Technology Data Exchange (ETDEWEB)

    Volk, K.; Klein, H.; Lakatos, A.; Maaser, A.; Weber, M. [Frankfurt Univ. (Germany). Inst. fuer Angewandte Physik

    1995-11-01

    The development of high current positive and negative ion sources is an essential issue for the next generation of high current linear accelerators. Especially, the design of the European Spallation Source facility (ESS) and the International Fusion Material Irradiation Test Facility (IFMIF) have increased the significance of high brightness hydrogen and deuterium sources. As an example, for the ESS facility, two H{sup -}-sources each delivering a 70 mA H{sup -}-beam in 1.45 ms pulses at a repetition rate of 50 Hz are necessary. A low emittance is another important prerequisite. The source must operate, while meeting the performance requirements, with a constancy and reliability over an acceptable period of time. The present paper summarizes the progress achieved in ion sources development of intense, single charge, positive and negative ion beams. (author) 16 figs., 7 refs.

  2. High current ion source development at Frankfurt

    International Nuclear Information System (INIS)

    Volk, K.; Klein, H.; Lakatos, A.; Maaser, A.; Weber, M.

    1995-01-01

    The development of high current positive and negative ion sources is an essential issue for the next generation of high current linear accelerators. Especially, the design of the European Spallation Source facility (ESS) and the International Fusion Material Irradiation Test Facility (IFMIF) have increased the significance of high brightness hydrogen and deuterium sources. As an example, for the ESS facility, two H - -sources each delivering a 70 mA H - -beam in 1.45 ms pulses at a repetition rate of 50 Hz are necessary. A low emittance is another important prerequisite. The source must operate, while meeting the performance requirements, with a constancy and reliability over an acceptable period of time. The present paper summarizes the progress achieved in ion sources development of intense, single charge, positive and negative ion beams. (author) 16 figs., 7 refs

  3. Particle accelerators and lasers high energy sources

    International Nuclear Information System (INIS)

    Watteau, J.P.

    1985-04-01

    Particle accelerators and lasers are to-day precious devices for physicist and engineer. Their performance and scope do not stop growing. Producing thin beams of high energy particles or photons, they are able to be very high energy sources which interact strongly with matter. Numerous applications use them: research, industry, communication, medicine, agroalimentary, defence, and soon. In this note, their operation principles are described and some examples of their use as high energy sources are given [fr

  4. Dietary phytic acid modulates characteristics of the colonic luminal environment and reduces serum levels of proinflammatory cytokines in rats fed a high-fat diet.

    Science.gov (United States)

    Okazaki, Yukako; Katayama, Tetsuyuki

    2014-12-01

    Dietary phytic acid (PA; myo-inositol [MI] hexaphosphate) is known to inhibit colon carcinogenesis in rodents. Dietary fiber, which is a negative risk factor of colon cancer, improves characteristics of the colonic environment, such as the content of organic acids and microflora. We hypothesized that dietary PA would improve the colonic luminal environment in rats fed a high-fat diet. To test this hypothesis, rats were fed diets containing 30% beef tallow with 2.04% sodium PA, 0.4% MI, or 1.02% sodium PA + 0.2% MI for 3 weeks. Compared with the control diet, the sodium PA diet up-regulated cecal organic acids, including acetate, propionate, and n-butyrate; this effect was especially prominent for cecal butyrate. The sodium PA + MI diet also significantly increased cecal butyrate, although this effect was less pronounced when compared with the sodium PA diet. The cecal ratio of Lactobacillales, cecal and fecal mucins (an index of intestinal barrier function), and fecal β-glucosidase activity were higher in rats fed the sodium PA diet than in those fed the control diet. The sodium PA, MI, and sodium PA + MI diets decreased levels of serum tumor necrosis factor α, which is a proinflammatory cytokine. Another proinflammatory cytokine, serum interleukin-6, was also down-regulated by the sodium PA and sodium PA + MI diets. These data showed that PA may improve the composition of cecal organic acids, microflora, and mucins, and it may decrease the levels of serum proinflammatory cytokines in rats fed a high-fat, mineral-sufficient diet. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. SPECTROSCOPIC OBSERVATIONS OF SN 2012fr: A LUMINOUS, NORMAL TYPE Ia SUPERNOVA WITH EARLY HIGH-VELOCITY FEATURES AND A LATE VELOCITY PLATEAU

    International Nuclear Information System (INIS)

    Childress, M. J.; Scalzo, R. A.; Sim, S. A.; Tucker, B. E.; Yuan, F.; Schmidt, B. P.; Cenko, S. B.; Filippenko, A. V.; Silverman, J. M.; Contreras, C.; Hsiao, E. Y.; Phillips, M.; Morrell, N.; Jha, S. W.; McCully, C.; Anderson, J. P.; De Jaeger, T.; Forster, F.; Benetti, S.; Bufano, F.

    2013-01-01

    We present 65 optical spectra of the Type Ia SN 2012fr, 33 of which were obtained before maximum light. At early times, SN 2012fr shows clear evidence of a high-velocity feature (HVF) in the Si II λ6355 line that can be cleanly decoupled from the lower velocity ''photospheric'' component. This Si II λ6355 HVF fades by phase –5; subsequently, the photospheric component exhibits a very narrow velocity width and remains at a nearly constant velocity of ∼12,000 km s –1 until at least five weeks after maximum brightness. The Ca II infrared triplet exhibits similar evidence for both a photospheric component at v ≈ 12,000 km s –1 with narrow line width and long velocity plateau, as well as an HVF beginning at v ≈ 31,000 km s –1 two weeks before maximum. SN 2012fr resides on the border between the ''shallow silicon'' and ''core-normal'' subclasses in the Branch et al. classification scheme, and on the border between normal and high-velocity Type Ia supernovae (SNe Ia) in the Wang et al. system. Though it is a clear member of the ''low velocity gradient'' group of SNe Ia and exhibits a very slow light-curve decline, it shows key dissimilarities with the overluminous SN 1991T or SN 1999aa subclasses of SNe Ia. SN 2012fr represents a well-observed SN Ia at the luminous end of the normal SN Ia distribution and a key transitional event between nominal spectroscopic subclasses of SNe Ia.

  6. LUMINOUS AND HIGH STELLAR MASS CANDIDATE GALAXIES AT z ≈ 8 DISCOVERED IN THE COSMIC ASSEMBLY NEAR-INFRARED DEEP EXTRAGALACTIC LEGACY SURVEY

    International Nuclear Information System (INIS)

    Yan Haojing; Finkelstein, Steven L.; Huang, Kuang-Han; Ryan, Russell E.; Ferguson, Henry C.; Koekemoer, Anton M.; Grogin, Norman A.; Dickinson, Mark; Newman, Jeffrey A.; Somerville, Rachel S.; Davé, Romeel; Faber, S. M.; Papovich, Casey; Guo Yicheng; Giavalisco, Mauro; Lee, Kyoung-soo; Reddy, Naveen; Siana, Brian D.; Cooray, Asantha R.; Hathi, Nimish P.

    2012-01-01

    One key goal of the Hubble Space Telescope Cosmic Assembly Near-Infrared Deep Extragalactic Legacy Survey is to track galaxy evolution back to z ≈ 8. Its two-tiered ''wide and deep'' strategy bridges significant gaps in existing near-infrared surveys. Here we report on z ≈ 8 galaxy candidates selected as F105W-band dropouts in one of its deep fields, which covers 50.1 arcmin 2 to 4 ks depth in each of three near-infrared bands in the Great Observatories Origins Deep Survey southern field. Two of our candidates have J 1 mag brighter than any previously known F105W-dropouts. We derive constraints on the bright end of the rest-frame ultraviolet luminosity function of galaxies at z ≈ 8, and show that the number density of such very bright objects is higher than expected from the previous Schechter luminosity function estimates at this redshift. Another two candidates are securely detected in Spitzer Infrared Array Camera images, which are the first such individual detections at z ≈ 8. Their derived stellar masses are on the order of a few × 10 9 M ☉ , from which we obtain the first measurement of the high-mass end of the galaxy stellar mass function at z ≈ 8. The high number density of very luminous and very massive galaxies at z ≈ 8, if real, could imply a large stellar-to-halo mass ratio and an efficient conversion of baryons to stars at such an early time.

  7. To assess the intimal thickness, flow velocities, and luminal diameter of carotid arteries using high-resolution B-mode ultrasound doppler imaging

    Science.gov (United States)

    Vemuru, Madhuri; Jabbar, Afzal; Chandra, Suman

    2004-04-01

    Carotid imaging is a Gold Standard test that provides useful information about the structure and functions of carotid arteries. Spectral imaging helps to evaluate the vessel and hemodynamic changes. High resolution B-mode imaging has emerged as one of the methods of choice for determining the anatomic extent of atherosclerosis and its progression and for assessing cardiovascular risks. The measurements made with Doppler correlate well with pathologic measurements. Recent prospective studies have clearly demonstrated that these measurements of carotid intimal thickness are potent predictors of Myocardial Infarction and Stroke. This method appears very attractive as it is non-invasive, extremely safe, well accepted by the patient and relatively inexpensive. It can be performed serially and has the advantage of visualizing the arterial wall in contrast to angiographic techniques which provide only an outline of the arterial lumen. Recently, there has been an interest in the clinical use of this technique in making difficult clinical decisions like deciding on preventive therapies. 30 subjects aged 21-60 years and 30 subjects aged 61-85 years of both sexes are selected after doing a baseline study to exclude Hypertension, Diabetes, Obesity and Hyperlipidemia. The carotid arteries were examined for intimal thickening, blood flow velocities and luminal diameter. With aging there is a narrowing of the carotid vessels and significant increase in intimal thickening with a consequent increase in the blood flow velocities. Inter-observer, intra-observer and instrument variations are seen and there is no significant change in the values when the distal flow pattern is considered for measurements. Aging produces major cardiovascular changes including decreased elasticity and compliance of great arteries leading to structural and functional alterations in heart and vessels. With aging there is increased intimal thickness and increased pulse wave velocity which is clearly

  8. High-Energy Compton Scattering Light Sources

    CERN Document Server

    Hartemann, Fred V; Barty, C; Crane, John; Gibson, David J; Hartouni, E P; Tremaine, Aaron M

    2005-01-01

    No monochromatic, high-brightness, tunable light sources currently exist above 100 keV. Important applications that would benefit from such new hard x-ray sources include: nuclear resonance fluorescence spectroscopy, time-resolved positron annihilation spectroscopy, and MeV flash radiography. The peak brightness of Compton scattering light sources is derived for head-on collisions and found to scale with the electron beam brightness and the drive laser pulse energy. This gamma 2

  9. Construction of a high beta plasma source

    International Nuclear Information System (INIS)

    Naraghi, M.; Torabi-Fard, A.

    1976-02-01

    A high beta plasma source has been designed and constructed. This source will serve as a means of developing and exercising different diagnostic techniques as required for ALVAND I, linear theta pinch experiment. Also, it will serve to acquaint the technicians with some of the techniques and safety rules of high voltage and capacitor discharge experiments. The operating parameters of the theta pinch and Z-pinch preionization is presented and the program of diagnostic measurements on the high beta plasma source is discussed

  10. High energy particle accelerators as radiation Sources

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, M E [National Center for Nuclear Safety and Radiation Vontrol, Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    Small accelerators in the energy range of few million electron volts are usually used as radiation sources for various applications, like radiotherapy, food irradiation, radiation sterilization and in other industrial applications. High energy accelerators with energies reaching billions of electron volts also find wide field of applications as radiation sources. Synchrotrons with high energy range have unique features as radiation sources. This review presents a synopsis of cyclic accelerators with description of phase stability principle of high energy accelerators with emphasis on synchrotrons. Properties of synchrotron radiation are given together with their applications in basic and applied research. 13 figs.,1 tab.

  11. ECRIS sources for highly charged ions

    International Nuclear Information System (INIS)

    Geller, R.

    1991-01-01

    The so-called Philips ionization gauge ion sources (PIGIS) were used until quite recently in heavy ion accelerators so multiply charged ions could only be obtained by incorporating a stripper to remove electrons. Electron cyclotron resonance ion sources (ECRIS) now dominate as they produce more highly charged ions. (orig.)

  12. An Inexpensive Source of High Voltage

    Science.gov (United States)

    Saraiva, Carlos

    2012-01-01

    As a physics teacher I like recycling old apparatus and using them for demonstrations in my classes. In physics laboratories in schools, sources of high voltage include induction coils or electronic systems that can be bought from companies that sell lab equipment. But these sources can be very expensive. In this article, I will explain how you…

  13. Simple, high current, antimony ion source

    International Nuclear Information System (INIS)

    Sugiura, H.

    1979-01-01

    A simple metal ion source capable of producing a continuous, uncontaminated, high current beam of Sb ions is presented. It produced a total ion current of 200 μA at 1 kV extraction voltage. A discharge occurred in the source at a pressure of 6 x 10 -4 Torr. The ion current extracted from the source increased with the 3/2 power of the extraction voltage. The perveance of the source and ion density in the plasma were 8 x 10 -9 and 1.8 x 10 11 cm -3 , respectively

  14. High energy neutrinos: sources and fluxes

    Energy Technology Data Exchange (ETDEWEB)

    Stanev, Todor [Bartol Research Institute, Department of Physics and Astronomy, University of Delaware, Newark DE 19716 (United States)

    2006-05-15

    We discuss briefly the potential sources of high energy astrophysical neutrinos and show estimates of the neutrino fluxes that they can produce. A special attention is paid to the connection between the highest energy cosmic rays and astrophysical neutrinos.

  15. NuSTAR discovery of a young, energetic pulsar associated with the luminous gamma-ray source Hess J1640-465

    DEFF Research Database (Denmark)

    Gotthelf, E. V.; Tomsick, J. A.; Halpern, J. P.

    2014-01-01

    We report the discovery of a 206 ms pulsar associated with the TeV γ-ray source HESS J1640-465 using the Nuclear Spectroscopic Telescope Array (NuSTAR) X-ray observatory. PSR J1640-4631 lies within the shell-type supernova remnant (SNR) G338.3-0.0, and coincides with an X-ray point source...... and putative pulsar wind nebula (PWN) previously identified in XMM-Newton and Chandra images. It is spinning down rapidly with period derivative 9.758(44) × 10-13, yielding a spin-down luminosity 4.4 × 1036 erg s-1, characteristic age 3350 yr, and surface dipole magnetic field strength Bs = 1.4 × 1013 G....... For the measured distance of 12 kpc to G338.3-0.0, the 0.2-10 TeV luminosity of HESS J1640-465 is 6% of the pulsar's present . The Fermi source 1FHL J1640.5-4634 is marginally coincident with PSR J1640-4631, but we find no γ-ray pulsations in a search using five years of Fermi Large Area Telescope (LAT) data...

  16. Luminous Phenomena - A Scientific Investigation of Anomalous Luminous Atmospheric Phenomena

    Science.gov (United States)

    Teodorani, M.

    2003-12-01

    Anomalous atmospheric luminous phenomena reoccur in several locations of Earth, in the form of multi-color light balls characterized by large dimensions, erratic motion, long duration and a correlated electromagnetic field. The author (an astrophysicist) of this book, which is organized as a selection of some of his technical and popularizing papers and seminars, describes and discusses all the efforts that have been done in 10 years, through several missions and a massive data analysis, in order to obtain some scientific explanation of this kind of anomalies, in particular the Hessdalen anomaly in Norway. The following topics are treated in the book: a) geographic archive of the areas of Earth where such phenomena are known to reoccur most often; b) observational techniques of astrophysical kind that have been used to acquire the data; c) main scientific results obtained so far; d) physical interpretation and natural hypothesis vs. ETV hypothesis; e) historical and chronological issues; f) the importance to brindle new energy sources; g) the importance to keep distance from any kind of "ufology". An unpublished chapter is entirely devoted to a detailed scientific investigation project of light phenomena reoccurring on the Ontario lake; the chosen new-generation multi-wavelength sensing instrumentation that is planned to be used in future missions in that specific area, is described together with scientific rationale and planned procedures. The main results, which were obtained in other areas of the world, such as the Arizona desert, USA and the Sibillini Mountains, Italy, are also briefly mentioned. One chapter is entirely dedicated to the presentation of extensive abstracts of technical papers by the author concerning this specific subject. The book is accompanied with a rich source of bibliographic references.

  17. NuSTAR Discovery Of A Young, Energetic Pulsar Associated with the Luminous Gamma-Ray Source HESS J1640-465

    Science.gov (United States)

    Gotthelf, E. V.; Tomsick, J. A.; Halpern, J. P.; Gelfand, J. D.; Harrison, F. A.; Boggs, S. E.; Christensen, F. E.; Craig, W. W.; Hailey, J. C.; Kaspi, V. M.; hide

    2014-01-01

    We report the discovery of a 206 ms pulsar associated with the TeV gamme-ray source HESS J1640-465 using the Nuclear Spectroscopic Telescope Array (NuSTAR) X-ray observatory. PSR J1640-4631 lies within the shelltype supernova remnant (SNR) G338.3-0.0, and coincides with an X-ray point source and putative pulsar wind nebula (PWN) previously identified in XMM-Newton and Chandra images. It is spinning down rapidly with period derivative P = 9.758(44) × 10(exp -13), yielding a spin-down luminosity E = 4.4 × 10(exp 36) erg s(exp -1), characteristic age tau(sub c) if and only if P/2 P = 3350 yr, and surface dipole magnetic field strength B(sub s) = 1.4×10(exp 13) G. For the measured distance of 12 kpc to G338.3-0.0, the 0.2-10 TeV luminosity of HESS J1640-465 is 6% of the pulsar's present E. The Fermi source 1FHL J1640.5-4634 is marginally coincident with PSR J1640-4631, but we find no gamma-ray pulsations in a search using five years of Fermi Large Area Telescope (LAT) data. The pulsar energetics support an evolutionary PWN model for the broadband spectrum of HESS J1640-465, provided that the pulsar's braking index is n approximately equal to 2, and that its initial spin period was P(sub 0) approximately 15 ms.

  18. NuSTAR discovery of a young, energetic pulsar associated with the luminous gamma-ray source HESS J1640–465

    Energy Technology Data Exchange (ETDEWEB)

    Gotthelf, E. V.; Halpern, J. P.; Hailey, J. C. [Columbia Astrophysics Laboratory, Columbia University, 550 West 120th Street, New York, NY 10027-6601 (United States); Tomsick, J. A.; Boggs, S. E.; Craig, W. W. [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Gelfand, J. D. [NYU Abu Dhabi, PO Box 129188, Abu Dhabi (United Arab Emirates); Harrison, F. A. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Christensen, F. E. [DTU Space-National Space Institute, Technical University of Denmark, Elektrovej 327, 2800 Lyngby (Denmark); Kaspi, V. M. [Department of Physics, McGill University, Montreal, QC H3A 2T8 (Canada); Stern, D. K. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Zhang, W. W., E-mail: eric@astro.columbia.edu [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2014-06-20

    We report the discovery of a 206 ms pulsar associated with the TeV γ-ray source HESS J1640–465 using the Nuclear Spectroscopic Telescope Array (NuSTAR) X-ray observatory. PSR J1640–4631 lies within the shell-type supernova remnant (SNR) G338.3–0.0, and coincides with an X-ray point source and putative pulsar wind nebula (PWN) previously identified in XMM-Newton and Chandra images. It is spinning down rapidly with period derivative P-dot = 9.758(44) × 10{sup –13}, yielding a spin-down luminosity E-dot = 4.4 × 10{sup 36} erg s{sup –1}, characteristic age τ{sub c}≡P/2 P-dot = 3350 yr, and surface dipole magnetic field strength B{sub s} = 1.4 × 10{sup 13} G. For the measured distance of 12 kpc to G338.3–0.0, the 0.2-10 TeV luminosity of HESS J1640–465 is 6% of the pulsar's present E-dot . The Fermi source 1FHL J1640.5–4634 is marginally coincident with PSR J1640–4631, but we find no γ-ray pulsations in a search using five years of Fermi Large Area Telescope (LAT) data. The pulsar energetics support an evolutionary PWN model for the broadband spectrum of HESS J1640–465, provided that the pulsar's braking index is n ≈ 2, and that its initial spin period was P {sub 0} ∼ 15 ms.

  19. High gradient accelerators for linear light sources

    International Nuclear Information System (INIS)

    Barletta, W.A.

    1988-01-01

    Ultra-high gradient radio frequency linacs powered by relativistic klystrons appear to be able to provide compact sources of radiation at XUV and soft x-ray wavelengths with a duration of 1 picosecond or less. This paper provides a tutorial review of the physics applicable to scaling the present experience of the accelerator community to the regime applicable to compact linear light sources. 22 refs., 11 figs., 21 tabs

  20. Cinematography of weakly - luminous transient phenomena using image converters; Cinematographie de phenomenes transitoires faiblement lumineux a l'aide d'amplificateurs de luminance

    Energy Technology Data Exchange (ETDEWEB)

    Stevenin, P.; Jacquot, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Services de Physique Appliquee, Service d' Ionique Generale

    1966-07-01

    After a review on the physical of optical informations emitted by a light source of weak intensity and short duration, the authors describe a high gain device by associating two image converters. The present specifications are given in the domain of high speed cinematography and spectrometry. (authors) [French] Apres avoir rappele la limitation d'origine physique du nombre d'informations optiques en provenance d'une source lumineuse de faible intensite et de courte duree, on decrit un appareillage a haut gain associant deux amplificateurs de luminance. On donne les performances actuelles du dispositif dans le domaine de la cinematographie et de la spectrometrie ultra-rapides. (auteurs)

  1. Study on the luminous characteristics of a natural ball lightning

    Science.gov (United States)

    Wang, Hao; Yuan, Ping; Cen, Jianyong; Liu, Guorong

    2018-02-01

    According to the optical images of the whole process of a natural ball lightning recorded by two slit-less spectrographs in the Qinghai plateau of China, the simulated observation experiment on the luminous intensity of the spherical light source was carried out. The luminous intensity and the optical power of the natural ball lightning in the wavelength range of 400-690 nm were estimated based on the experimental data and the Lambert-Beer Law. The results show that the maximum luminous intensity was about 1.24 × 105 cd in the initial stage of the natural ball lightning, and the maximum luminous intensity and the maximum optical power in most time of its life were about 5.9 × 104 cd and 4.2 × 103 W, respectively.

  2. A Practical Device for Measuring the Luminance Distribution

    Directory of Open Access Journals (Sweden)

    Thijs Kruisselbrink

    2017-06-01

    Full Text Available Various applications in building lighting such as automated daylight systems, dynamic lighting control systems, lighting simulations, and glare analyzes can be optimized using information on the actual luminance distributions of the surroundings. Currently, commercially available luminance distribution measurement devices are often not suitable for these kind of applications or simply too expensive for broad application. This paper describes the development of a practical and autonomous luminance distribution measurement device based on a credit card-sized single-board computer and a camera system. The luminance distribution was determined by capturing High Dynamic Range images and translating the RGB information to the CIE XYZ color space. The High Dynamic Range technology was essential to accurately capture the data needed to calculate the luminance distribution because it allows to capture luminance ranges occurring in real scenarios. The measurement results were represented in accordance with established methods in the field of daylighting. Measurements showed that the accuracy of the luminance distribution measurement device ranged from 5% to 20% (worst case which was deemed acceptable for practical measurements and broad applications in the building realm.

  3. High Dynamic Performance Nonlinear Source Emulator

    DEFF Research Database (Denmark)

    Nguyen-Duy, Khiem; Knott, Arnold; Andersen, Michael A. E.

    2016-01-01

    As research and development of renewable and clean energy based systems is advancing rapidly, the nonlinear source emulator (NSE) is becoming very essential for testing of maximum power point trackers or downstream converters. Renewable and clean energy sources play important roles in both...... terrestrial and nonterrestrial applications. However, most existing NSEs have only been concerned with simulating energy sources in terrestrial applications, which may not be fast enough for testing of nonterrestrial applications. In this paper, a high-bandwidth NSE is developed that is able to simulate...... change in the input source but also to a load step between nominal and open circuit. Moreover, all of these operation modes have a very fast settling time of only 10 μs, which is hundreds of times faster than that of existing works. This attribute allows for higher speed and a more efficient maximum...

  4. High Intensity High Charge State ECR Ion Sources

    CERN Document Server

    Leitner, Daniela

    2005-01-01

    The next-generation heavy ion beam accelerators such as the proposed Rare Isotope Accelerator (RIA), the Radioactive Ion Beam Factory at RIKEN, the GSI upgrade project, the LHC-upgrade, and IMP in Lanzhou require a great variety of high charge state ion beams with a magnitude higher beam intensity than currently achievable. High performance Electron Cyclotron Resonance (ECR) ion sources can provide the flexibility since they can routinely produce beams from hydrogen to uranium. Over the last three decades, ECR ion sources have continued improving the available ion beam intensities by increasing the magnetic fields and ECR heating frequencies to enhance the confinement and the plasma density. With advances in superconducting magnet technology, a new generation of high field superconducting sources is now emerging, designed to meet the requirements of these next generation accelerator projects. The talk will briefly review the field of high performance ECR ion sources and the latest developments for high intens...

  5. Luminance-based specular gloss characterization

    OpenAIRE

    Leloup, Frédéric; Pointer, Michael R.; Dutré, Philip; Hanselaer, Peter

    2011-01-01

    Gloss is a feature of visual appearance that arises from the directionally selective reflection of light incident on a surface. Especially when a distinct reflected image is perceptible, the luminance distribution of the illumination scene above the sample can strongly influence the gloss perception. For this reason, industrial glossmeters do not provide a satisfactory gloss estimation of high-gloss surfaces. In this study, the influence of the conditions of illumination on specular ...

  6. Surface ionization ion source with high current

    International Nuclear Information System (INIS)

    Fang Jinqing; Lin Zhizhou; Yu Lihua; Zhan Rongan; Huang Guojun; Wu Jianhua

    1986-04-01

    The working principle and structure of a surface ionization ion source with high current is described systematically. Some technological keypoints of the ion source are given in more detail, mainly including: choosing and shaping of the material of the surface ionizer, heating of the ionizer, distributing of working vapour on the ionizer surface, the flow control, the cooling problem at the non-ionization surface and the ion optics, etc. This ion source has been used since 1972 in the electromagnetic isotope separator with 180 deg angle. It is suitable for separating isotopes of alkali metals and rare earth metals. For instance, in the case of separating Rubidium, the maximum ion current of Rbsup(+) extracted from the ion source is about 120 mA, the maximum ion current accepted by the receiver is about 66 mA, the average ion current is more than 25 mA. The results show that our ion source have advantages of high ion current, good characteristics of focusing ion beam, working stability and structure reliability etc. It may be extended to other fields. Finally, some interesting phenomena in the experiment are disccused briefly. Some problems which should be investigated are further pointed out

  7. Robust brightness enhancement across a luminance range of the glare illusion.

    Science.gov (United States)

    Tamura, Hideki; Nakauchi, Shigeki; Koida, Kowa

    2016-01-01

    The glare illusion refers to brightness enhancement and the perception of a self-luminous appearance that occurs when a central region is surrounded by a luminance gradient. The center region appears to be a light source, with its light dispersing into the surrounding region. If the luminous edge is critical for generating the illusion, modulating the perceived luminance of the image, and switching its appearance from luminous to nonluminous, would have a strong impact on lightness and brightness estimation. Here, we quantified the illusion in two ways, by assessing brightness enhancement and examining whether the center region appeared luminous. Thus, we could determine whether the two effects occurred jointly or independently. We examined a wide luminance range of center regions, from 0 to 200% relative to background. Brightness enhancement in the illusion was observed for a wide range of luminances (20% to 200% relative to background), while a luminous-white appearance was observed when the center region luminance was 145% of the background. These results exclude the possibility that brightness enhancement occurs because the stimuli appear self-luminous. We suggest that restoring the original image intensity precedes the perceptual process of lightness estimation.

  8. High-energy astrophysics and the search for sources of gravitational waves.

    Science.gov (United States)

    O'Brien, P T; Evans, P

    2018-05-28

    The dawn of the gravitational-wave (GW) era has sparked a greatly renewed interest into possible links between sources of high-energy radiation and GWs. The most luminous high-energy sources-gamma-ray bursts (GRBs)-have long been considered as very likely sources of GWs, particularly from short-duration GRBs, which are thought to originate from the merger of two compact objects such as binary neutron stars and a neutron star-black hole binary. In this paper, we discuss: (i) the high-energy emission from short-duration GRBs; (ii) what other sources of high-energy radiation may be observed from binary mergers; and (iii) how searches for high-energy electromagnetic counterparts to GW events are performed with current space facilities. While current high-energy facilities, such as Swift and Fermi, play a crucial role in the search for electromagnetic counterparts, new space missions will greatly enhance our capabilities for joint observations. We discuss why such facilities, which incorporate new technology that enables very wide-field X-ray imaging, are required if we are to truly exploit the multi-messenger era.This article is part of a discussion meeting issue 'The promises of gravitational-wave astronomy'. © 2018 The Author(s).

  9. High-energy astrophysics and the search for sources of gravitational waves

    Science.gov (United States)

    O'Brien, P. T.; Evans, P.

    2018-05-01

    The dawn of the gravitational-wave (GW) era has sparked a greatly renewed interest into possible links between sources of high-energy radiation and GWs. The most luminous high-energy sources-gamma-ray bursts (GRBs)-have long been considered as very likely sources of GWs, particularly from short-duration GRBs, which are thought to originate from the merger of two compact objects such as binary neutron stars and a neutron star-black hole binary. In this paper, we discuss: (i) the high-energy emission from short-duration GRBs; (ii) what other sources of high-energy radiation may be observed from binary mergers; and (iii) how searches for high-energy electromagnetic counterparts to GW events are performed with current space facilities. While current high-energy facilities, such as Swift and Fermi, play a crucial role in the search for electromagnetic counterparts, new space missions will greatly enhance our capabilities for joint observations. We discuss why such facilities, which incorporate new technology that enables very wide-field X-ray imaging, are required if we are to truly exploit the multi-messenger era. This article is part of a discussion meeting issue `The promises of gravitational-wave astronomy'.

  10. Life prediction of OLED for constant-stress accelerated degradation tests using luminance decaying model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jianping, E-mail: jpzhanglzu@163.com [College of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai 200090 (China); Li, Wenbin [College of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai 200090 (China); Cheng, Guoliang; Chen, Xiao [Shanghai Tianyi Electric Co., Ltd., Shanghai 201611 (China); Wu, Helen [School of Computing, Engineering and Mathematics, University of Western Sydney, Sydney 2751 (Australia); Herman Shen, M.-H. [Department of Mechanical and Aerospace Engineering, The Ohio State University, OH 43210 (United States)

    2014-10-15

    In order to acquire the life information of organic light emitting diode (OLED), three groups of constant stress accelerated degradation tests are performed to obtain the luminance decaying data of samples under the condition that the luminance and the current are respectively selected as the indicator of performance degradation and the test stress. Weibull function is applied to describe the relationship between luminance decaying and time, least square method (LSM) is employed to calculate the shape parameter and scale parameter, and the life prediction of OLED is achieved. The numerical results indicate that the accelerated degradation test and the luminance decaying model reveal the luminance decaying law of OLED. The luminance decaying formula fits the test data very well, and the average error of fitting value compared with the test data is small. Furthermore, the accuracy of the OLED life predicted by luminance decaying model is high, which enable rapid estimation of OLED life and provide significant guidelines to help engineers make decisions in design and manufacturing strategy from the aspect of reliability life. - Highlights: • We gain luminance decaying data by accelerated degradation tests on OLED. • The luminance decaying model objectively reveals the decaying law of OLED luminance. • The least square method (LSM) is employed to calculate Weibull parameters. • The plan designed for accelerated degradation tests proves to be feasible. • The accuracy of the OLED life and the luminance decaying fitting formula is high.

  11. Life prediction of OLED for constant-stress accelerated degradation tests using luminance decaying model

    International Nuclear Information System (INIS)

    Zhang, Jianping; Li, Wenbin; Cheng, Guoliang; Chen, Xiao; Wu, Helen; Herman Shen, M.-H.

    2014-01-01

    In order to acquire the life information of organic light emitting diode (OLED), three groups of constant stress accelerated degradation tests are performed to obtain the luminance decaying data of samples under the condition that the luminance and the current are respectively selected as the indicator of performance degradation and the test stress. Weibull function is applied to describe the relationship between luminance decaying and time, least square method (LSM) is employed to calculate the shape parameter and scale parameter, and the life prediction of OLED is achieved. The numerical results indicate that the accelerated degradation test and the luminance decaying model reveal the luminance decaying law of OLED. The luminance decaying formula fits the test data very well, and the average error of fitting value compared with the test data is small. Furthermore, the accuracy of the OLED life predicted by luminance decaying model is high, which enable rapid estimation of OLED life and provide significant guidelines to help engineers make decisions in design and manufacturing strategy from the aspect of reliability life. - Highlights: • We gain luminance decaying data by accelerated degradation tests on OLED. • The luminance decaying model objectively reveals the decaying law of OLED luminance. • The least square method (LSM) is employed to calculate Weibull parameters. • The plan designed for accelerated degradation tests proves to be feasible. • The accuracy of the OLED life and the luminance decaying fitting formula is high

  12. Compact high-power terahertz radiation source

    Directory of Open Access Journals (Sweden)

    G. A. Krafft

    2004-06-01

    Full Text Available In this paper a new type of THz radiation source, based on recirculating an electron beam through a high gradient superconducting radio frequency cavity, and using this beam to drive a standard electromagnetic undulator on the return leg, is discussed. Because the beam is recirculated and not stored, short bunches may be produced that radiate coherently in the undulator, yielding exceptionally high average THz power for relatively low average beam power. Deceleration from the coherent emission, and the detuning it causes, limits the charge-per-bunch possible in such a device.

  13. Internal noise sources limiting contrast sensitivity.

    Science.gov (United States)

    Silvestre, Daphné; Arleo, Angelo; Allard, Rémy

    2018-02-07

    Contrast sensitivity varies substantially as a function of spatial frequency and luminance intensity. The variation as a function of luminance intensity is well known and characterized by three laws that can be attributed to the impact of three internal noise sources: early spontaneous neural activity limiting contrast sensitivity at low luminance intensities (i.e. early noise responsible for the linear law), probabilistic photon absorption at intermediate luminance intensities (i.e. photon noise responsible for de Vries-Rose law) and late spontaneous neural activity at high luminance intensities (i.e. late noise responsible for Weber's law). The aim of this study was to characterize how the impact of these three internal noise sources vary with spatial frequency and determine which one is limiting contrast sensitivity as a function of luminance intensity and spatial frequency. To estimate the impact of the different internal noise sources, the current study used an external noise paradigm to factorize contrast sensitivity into equivalent input noise and calculation efficiency over a wide range of luminance intensities and spatial frequencies. The impact of early and late noise was found to drop linearly with spatial frequency, whereas the impact of photon noise rose with spatial frequency due to ocular factors.

  14. PASOTRON high-energy microwave source

    Science.gov (United States)

    Goebel, Dan M.; Schumacher, Robert W.; Butler, Jennifer M.; Hyman, Jay, Jr.; Santoru, Joseph; Watkins, Ron M.; Harvey, Robin J.; Dolezal, Franklin A.; Eisenhart, Robert L.; Schneider, Authur J.

    1992-04-01

    A unique, high-energy microwave source, called PASOTRON (Plasma-Assisted Slow-wave Oscillator), has been developed. The PASOTRON utilizes a long-pulse E-gun and plasma- filled slow-wave structure (SWS) to produce high-energy pulses from a simple, lightweight device that utilizes no externally produced magnetic fields. Long pulses are obtained from a novel E-gun that employs a low-pressure glow discharge to provide a stable, high current- density electron source. The electron accelerator consists of a high-perveance, multi-aperture array. The E-beam is operated in the ion-focused regime where the plasma filling the SWS space-charge neutralizes the beam, and the self-pinch force compresses the beamlets and increases the beam current density. A scale-model PASOTRON, operating as a backward- wave oscillator in C-band with a 100-kV E-beam, has produced output powers in the 3 to 5 MW range and pulse lengths of over 100 microsecond(s) ec, corresponding to an integrated energy per pulse of up to 500 J. The E-beam to microwave-radiation power conversion efficiency is about 20%.

  15. Very Rapid High-amplitude Gamma-Ray Variability in Luminous Blazar PKS 1510-089 Studied with Fermi-LAT

    Energy Technology Data Exchange (ETDEWEB)

    Saito, S.; Stawarz, L.; Tanaka, Y.T.; Takahashi, T.; Madejski, G.; D' Ammando, F.

    2013-03-20

    Here we report on the detailed analysis of the γ-ray light curve of a luminous blazar PKS 1510-089 observed in the GeV range with the Large Area Telescope (LAT) onboard the Fermi satellite during the period 2011 September - December. By investigating the properties of the detected three major flares with the shortest possible time binning allowed by the photon statistics, we find a variety of temporal characteristics and variability patterns. This includes a clearly asymmetric profile (with a faster flux rise and a slower decay) of the flare resolved on sub-daily timescales, a superposition of many short uncorrelated flaring events forming the apparently coherent longer-duration outburst, and a huge single isolated outburst unresolved down to the timescale of three-hours. In the latter case we estimate the corresponding γ-ray flux doubling timescale to be below one hour, which is extreme and never previously reported for any active galaxy

  16. High energy cosmic rays: sources and fluxes

    Energy Technology Data Exchange (ETDEWEB)

    Stanev, Todor; Gaisser, Thomas K.; Tilav, Serap

    2014-04-01

    We discuss the production of a unique energy spectrum of the high energy cosmic rays detected with air showers by shifting the energy estimates of different detectors. After such a spectrum is generated we fit the spectrum with three or four populations of cosmic rays that might be accelerated at different cosmic ray sources. We also present the chemical composition that the fits of the spectrum generates and discuss some new data sets presented this summer at the ICRC in Rio de Janeiro that may require new global fits.

  17. Security of highly radioactive sources in Nepal

    International Nuclear Information System (INIS)

    Shrestha, Kamal K.

    2010-01-01

    Subsequent to 9/11, concerned countries and UN agencies have taken especial interest in the security of highly radioactive sources throughout the world. The IAEA Nuclear Security Plan (2006-2009) consequently made as a result of UN Security Council Resolution 1540 is binding to all States. The Global Threat Reduction Initiative (GTRI) of the US and the Global Threat Reduction Programme (GTRP) of UK have assisted the four hospitals in Nepal having more than 1,000 Curies of radioactivity in their Cobalt-60 sources used for teletherapy. The physical upgrade of the security of the nuclear materials has also been launched in Nepal for prevention of theft with malicious intention or threats. In this presentation, the radioisotopes in Nepal that comes under different categories according to TECDOC-1355 of IAEA will be described. Problems and issues regarding the security and protection of radioactive sources at hospitals, academic and research institutions that could be prevalent in many developing counties too will be discussed by taking a case study of one of the cancer hospitals in Kathmandu valley. (author)

  18. Considerations for high-brightness electron sources

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1990-01-01

    Particle accelerators are now used in many areas of physics research and in industrial and medical applications. New uses are being studied to address major societal needs in energy production, materials research, generation of intense beams of radiation at optical and suboptical wavelengths, treatment of various kinds of waste, and so on. Many of these modern applications require a high intensity beam at the desired energy, along with a very good beam quality in terms of the beam confinement, aiming, or focusing. Considerations for ion and electron accelerators are often different, but there are also many commonalties, and in fact, techniques derived for one should perhaps more often be considered for the other as well. We discuss some aspects of high-brightness electron sources here from that point of view. 6 refs

  19. The JLab high power ERL light source

    International Nuclear Information System (INIS)

    Neil, G.R.; Behre, C.; Benson, S.V.

    2006-01-01

    A new THz/IR/UV photon source at Jefferson Lab is the first of a new generation of light sources based on an Energy-Recovered (superconducting) Linac (ERL). The machine has a 160MeV electron beam and an average current of 10mA in 75MHz repetition rate hundred femtosecond bunches. These electron bunches pass through a magnetic chicane and therefore emit synchrotron radiation. For wavelengths longer than the electron bunch the electrons radiate coherently a broadband THz ∼ half cycle pulse whose average brightness is >5 orders of magnitude higher than synchrotron IR sources. Previous measurements showed 20W of average power extracted [Carr, et al., Nature 420 (2002) 153]. The new facility offers simultaneous synchrotron light from the visible through the FIR along with broadband THz production of 100fs pulses with >200W of average power. The FELs also provide record-breaking laser power [Neil, et al., Phys. Rev. Lett. 84 (2000) 662]: up to 10kW of average power in the IR from 1 to 14μm in 400fs pulses at up to 74.85MHz repetition rates and soon will produce similar pulses of 300-1000nm light at up to 3kW of average power from the UV FEL. These ultrashort pulses are ideal for maximizing the interaction with material surfaces. The optical beams are Gaussian with nearly perfect beam quality. See www.jlab.org/FEL for details of the operating characteristics; a wide variety of pulse train configurations are feasible from 10ms long at high repetition rates to continuous operation. The THz and IR system has been commissioned. The UV system is to follow in 2005. The light is transported to user laboratories for basic and applied research. Additional lasers synchronized to the FEL are also available. Past activities have included production of carbon nanotubes, studies of vibrational relaxation of interstitial hydrogen in silicon, pulsed laser deposition and ablation, nitriding of metals, and energy flow in proteins. This paper will present the status of the system and

  20. The JLab high power ERL light source

    Energy Technology Data Exchange (ETDEWEB)

    G.R. Neil; C. Behre; S.V. Benson; M. Bevins; G. Biallas; J. Boyce; J. Coleman; L.A. Dillon-Townes; D. Douglas; H.F. Dylla; R. Evans; A. Grippo; D. Gruber; J. Gubeli; D. Hardy; C. Hernandez-Garcia; K. Jordan; M.J. Kelley; L. Merminga; J. Mammosser; W. Moore; N. Nishimori; E. Pozdeyev; J. Preble; R. Rimmer; Michelle D. Shinn; T. Siggins; C. Tennant; R. Walker; G.P. Williams and S. Zhang

    2005-03-19

    A new THz/IR/UV photon source at Jefferson Lab is the first of a new generation of light sources based on an Energy-Recovered, (superconducting) Linac (ERL). The machine has a 160 MeV electron beam and an average current of 10 mA in 75 MHz repetition rate hundred femtosecond bunches. These electron bunches pass through a magnetic chicane and therefore emit synchrotron radiation. For wavelengths longer than the electron bunch the electrons radiate coherently a broadband THz {approx} half cycle pulse whose average brightness is > 5 orders of magnitude higher than synchrotron IR sources. Previous measurements showed 20 W of average power extracted[1]. The new facility offers simultaneous synchrotron light from the visible through the FIR along with broadband THz production of 100 fs pulses with >200 W of average power. The FELs also provide record-breaking laser power [2]: up to 10 kW of average power in the IR from 1 to 14 microns in 400 fs pulses at up to 74.85 MHz repetition rates and soon will produce similar pulses of 300-1000 nm light at up to 3 kW of average power from the UV FEL. These ultrashort pulses are ideal for maximizing the interaction with material surfaces. The optical beams are Gaussian with nearly perfect beam quality. See www.jlab.org/FEL for details of the operating characteristics; a wide variety of pulse train configurations are feasible from 10 microseconds long at high repetition rates to continuous operation. The THz and IR system has been commissioned. The UV system is to follow in 2005. The light is transported to user laboratories for basic and applied research. Additional lasers synchronized to the FEL are also available. Past activities have included production of carbon nanotubes, studies of vibrational relaxation of interstitial hydrogen in silicon, pulsed laser deposition and ablation, nitriding of metals, and energy flow in proteins. This paper will present the status of the system and discuss some of the discoveries we have made

  1. Signal detectability of mammography depends on film-screen system and luminance of view box

    International Nuclear Information System (INIS)

    Maeda, Fumie; Ogura, Akio; Miyai, Akira

    2003-01-01

    High-density film and the high-luminance view-box system are being recommended for mammograms owing to the improved detection of masses. However, this system causes an increase in radiation. Therefore, the purpose of this study was to assess whether the detection of masses would improve using the normal-luminance view box and normal-density film with different types of contrast systems. Low-contrast detection using receiver operating characteristic (ROC) analysis and high-contrast detection using an American College of Radiology (ACR) phantom were evaluated for the following systems: high-density film and high-luminance view box, normal-density film and normal-luminance view box, and normal-density film with wide latitude and normal-luminance view box. The results showed no significant variation in the detectability of the system with high-density film and high-luminance view box and the normal-density film with wide latitude and normal-luminance view box. However, in terms of low-contrast visibility, the system using normal-density film and normal-luminance view box was significantly reduced in comparison with the others. Therefore, the system with normal-density film with wide latitude and the normal-luminance view box is recommended because of reduced radiation dose. (author)

  2. Comparison of clinical outcomes between luminal invasive ductal carcinoma and luminal invasive lobular carcinoma.

    Science.gov (United States)

    Adachi, Yayoi; Ishiguro, Junko; Kotani, Haruru; Hisada, Tomoka; Ichikawa, Mari; Gondo, Naomi; Yoshimura, Akiyo; Kondo, Naoto; Hattori, Masaya; Sawaki, Masataka; Fujita, Takashi; Kikumori, Toyone; Yatabe, Yasushi; Kodera, Yasuhiro; Iwata, Hiroji

    2016-03-25

    The pathological and clinical features of invasive lobular carcinoma (ILC) differ from those of invasive ductal carcinoma (IDC). Several studies have indicated that patients with ILC have a better prognosis than those with ductal carcinoma. However, no previous study has considered the molecular subtypes and histological subtypes of ILC. We compared prognosis between IDC and classical, luminal type ILC and developed prognostic factors for early breast cancer patients with classical luminal ILC. Four thousand one hundred ten breast cancer patients were treated at the Aichi Cancer Center Hospital from 2003 to 2012. We identified 1,661 cases with luminal IDC and 105 cases with luminal classical ILC. We examined baseline characteristics, clinical outcomes, and prognostic factors of luminal ILC. The prognosis of luminal ILC was significantly worse than that of luminal IDC. The rates of 5-year disease free survival (DFS) were 91.9% and 88.4% for patients with luminal IDC and luminal ILC, respectively (P = 0.008). The rates of 5-year overall survival (OS) were 97.6% and 93.1% for patients with luminal IDC and luminal ILC respectively (P = 0.030). Although we analyzed prognosis according to stratification by tumor size, luminal ILC tended to have worse DFS than luminal IDC in the large tumor group. In addition, although our analysis was performed according to matching lymph node status, luminal ILC had a significantly worse DFS and OS than luminal IDC in node-positive patients. Survival curves showed that the prognosis for ILC became worse than IDC over time. Multivariate analysis showed that ILC was an important factor related to higher risk of recurrence of luminal type breast cancer, even when tumor size, lymph node status and histological grade were considered. Luminal ILC had worse outcomes than luminal IDC. Consequently, different treatment approaches should be used for luminal ILC than for luminal IDC.

  3. Very-High-Brightness Picosecond Electron Source

    International Nuclear Information System (INIS)

    Bluem, H.

    2003-01-01

    Bright, RF photocathode electron guns are the source of choice for most high-performance research accelerator applications. Some of these applications are pushing the performance boundaries of the present state-of-the-art guns. Advanced Energy Systems is developing a novel photocathode RF gun that shows excellent promise for extending gun performance. Initial gun simulations with only a short booster accelerator easily break the benchmark emittance of one micron for 1 nC of bunch charge. The pulse length in these simulations is less than 2 ps. It is expected that with more detailed optimization studies, the performance can be further improved. The performance details of the gun will be presented. In addition, we will discuss the present design concept along with the status of the project

  4. Physics of high intensity nanosecond electron source

    International Nuclear Information System (INIS)

    Herrera-Gomez, A.; Spicer, W.E.

    1993-08-01

    A new high-intensity, short-time electron source is now being used at the Stanford Linear Accelerator Center (SLAC). Using a GaAs negative affinity semiconductor in the construction of the cathode, it is possible to fulfill operation requirements such as peak currents of tens of amperes, peak widths of the order of nanoseconds, hundreds of hours of operation stability, and electron spin polarization. The cathode is illuminated with high intensity laser pulses, and photoemitted electrons constitute the yield. Because of the high currents, some nonlinear effects are present. Very noticeable is the so-called Charge Limit (CL) effect, which consists of a limit on the total charge in each pulse-that is, the total bunch charge stops increasing as the light pulse total energy increases. In this paper, we explain the mechanism of the CL and how it is caused by the photovoltaic effect. Our treatment is based on the Three-Step model of photoemission. We relate the CL to the characteristics of the surface and bulk of the semiconductor, such as doping, band bending, surface vacuum level, and density of surface states. We also discuss possible ways to prevent the Char's Level effect

  5. High repetition rate intense ion beam source

    International Nuclear Information System (INIS)

    Hammer, D.A.; Glidden, S.C.; Noonan, B.

    1992-01-01

    This final report describes a ≤ 150kV, 40kA, 100ns high repetition rate pulsed power system and intense ion beam source which is now in operation at Cornell University. Operation of the Magnetically-controlled Anode Plasma (MAP) ion diode at > 100Hz (burst mode for up to 10 pulse bursts) provides an initial look at repetition rate limitations of both the ion diode and beam diagnostics. The pulsed power systems are capable of ≥ 1kHz operation (up to 10 pulse bursts), but ion diode operation was limited to ∼100Hz because of diagnostic limitations. By varying MAP diode operating parameters, ion beams can be extracted at a few 10s of keV or at up to 150keV, the corresponding accelerating gap impedance ranging from about 1Ω to about 10Ω. The ability to make hundreds of test pulses per day at an average repetition rate of about 2 pulses per minute permits statistical analysis of diode operation as a function of various parameters. Most diode components have now survived more than 10 4 pulses, and the design and construction of the various pulsed power components of the MAP diode which have enabled us to reach this point are discussed. A high speed data acquisition system and companion analysis software capable of acquiring pulse data at 1ms intervals (in bursts of up to 10 pulses) and processing it in ≤ min is described

  6. Highly efficient sources of single indistinguishable photons

    DEFF Research Database (Denmark)

    Gregersen, Niels

    2013-01-01

    be electrically driven. Several design strategies addressing these requirements have been proposed. In the cavity-based source, light emission is controlled using resonant cavity quantum electrodynamics effects, whereas in the waveguide-based source, broadband electric field screening effects are employed......Solid-state sources capable of emitting single photons on demand are of great interest in quantum information applications. Ideally, such a source should emit exactly one photon into the collection optics per trigger, the emitted photons should be indistinguishable and the source should...

  7. A new interpretation of luminous blue stars

    International Nuclear Information System (INIS)

    Stothers, R.

    1976-01-01

    A major revision of current theoretical ideas about the brightest blue stars must be made if Carson's new radiative opacities are adopted in stellar models. Unlike earlier opacities, the new opacities exhibit a large ''bump'' due to CNO ionization, which leads to very strong central condensation, convective instability, and pulsational instability in hot, diffuse stellar envelopes (typically those in which L/M>10 3 solar units). Despite a number of theoretical uncertainties, the new picture of the structure of very luminous stars is reasonably successful in accounting for a variety of previously unexplained observations. Thus, the new stellar models for the phase of core hydrogen burning predict large radii and rather cool effective temperatures (which are yet to be observationally confirmed) for O stars, and a spreading out of the main-sequence band in the H-R diagram toward luminous cool supergiants for masses higher than approx.20 M/sub sun/, beginning at M/sub v/=-4.5 and Sp=B1. They also predict slower surface rotations for O stars compared with B stars; and, in binary systems, slower apsidal motions, closer rotational-revolutional synchronism, and smaller orbital eccentricities. In massive X-ray binary systems, circular orbits and supergiant-like visual companions are expected to be quite common. Radial pulsations of the models have been calculated by employing linearized nonadiabatic pulsation theory. Long-period variability is predicted to exist for massive blue supergiants of luminosity class Ia. The new models for helium stars predict large radii and rather cool effective temperatures for Wolf-Rayet stars, as well as multimodal pulsational instability and, possibly, surface turbulence for these stars. Ultrashort-period variability, observed in many classes of hot luminous stars, may be due, in part, to high radial overtone pulsations (or, possibly, to nonradial pulsation or convective modes)

  8. Photocathodes for High Repetition Rate Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, Ilan [Stony Brook Univ., NY (United States). Dept. of Physics and Astronomy. Center for Accelerator Science and Education

    2014-04-20

    This proposal brought together teams at Brookhaven National Laboratory (BNL), Lawrence Berkeley National Laboratory (LBNL) and Stony Brook University (SBU) to study photocathodes for high repetition rate light sources such as Free Electron Lasers (FEL) and Energy Recovery Linacs (ERL). Below details the Principal Investigators and contact information. Each PI submits separately for a budget through his corresponding institute. The work done under this grant comprises a comprehensive program on critical aspects of the production of the electron beams needed for future user facilities. Our program pioneered in situ and in operando diagnostics for alkali antimonide growth. The focus is on development of photocathodes for high repetition rate Free Electron Lasers (FELs) and Energy Recovery Linacs (ERLs), including testing SRF photoguns, both normal-­conducting and superconducting. Teams from BNL, LBNL and Stony Brook University (SBU) led this research, and coordinated their work over a range of topics. The work leveraged a robust infrastructure of existing facilities and the support was used for carrying out the research at these facilities. The program concentrated in three areas: a) Physics and chemistry of alkali-­antimonide cathodes (BNL – LBNL) b) Development and testing of a diamond amplifier for photocathodes (SBU -­ BNL) c) Tests of both cathodes in superconducting RF photoguns (SBU) and copper RF photoguns (LBNL) Our work made extensive use of synchrotron radiation materials science techniques, such as powder-­ and single-­crystal diffraction, x-­ray fluorescence, EXAFS and variable energy XPS. BNL and LBNL have many complementary facilities at the two light sources associated with these laboratories (NSLS and ALS, respectively); use of these will be a major thrust of our program and bring our understanding of these complex materials to a new level. In addition, CHESS at Cornell will be used to continue seamlessly throughout the NSLS dark period and

  9. The Jefferson Lab High Power Light Source

    Energy Technology Data Exchange (ETDEWEB)

    James R. Boyce

    2006-01-01

    Jefferson Lab has designed, built and operated two high average power free-electron lasers (FEL) using superconducting RF (SRF) technology and energy recovery techniques. Between 1999-2001 Jefferson Lab operated the IR Demo FEL. This device produced over 2 kW in the mid-infrared, in addition to producing world record average powers in the visible (50 W), ultraviolet (10 W) and terahertz range (50 W) for tunable, short-pulse (< ps) light. This FEL was the first high power demonstration of an accelerator configuration that is being exploited for a number of new accelerator-driven light source facilities that are currently under design or construction. The driver accelerator for the IR Demo FEL uses an Energy Recovered Linac (ERL) configuration that improves the energy efficiency and lowers both the capital and operating cost of such devices by recovering most of the power in the spent electron beam after optical power is extracted from the beam. The IR Demo FEL was de-commissioned in late 2001 for an upgraded FEL for extending the IR power to over 10 kW and the ultraviolet power to over 1 kW. The FEL Upgrade achieved 10 kW of average power in the mid-IR (6 microns) in July of 2004, and its IR operation currently is being extended down to 1 micron. In addition, we have demonstrated the capability of on/off cycling and recovering over a megawatt of electron beam power without diminishing machine performance. A complementary UV FEL will come on-line within the next year. This paper presents a summary of the FEL characteristics, user community accomplishments with the IR Demo, and planned user experiments.

  10. The luminous and the grey

    CERN Document Server

    Batchelor, David

    2014-01-01

    Color surrounds us: the lush green hues of trees and grasses, the variant blues of water and the sky, the bright pops of yellow and red from flowers. But at the same time, color lies at the limits of language and understanding. In this absorbing sequel to Chromophobia-which addresses the extremes of love and loathing provoked by color since antiquity-David Batchelor charts color's more ambiguous terrain.   The Luminous and the Grey explores the places where color comes into being and where it fades away, probing when it begins and when it ends both in the imagination and in the material world.

  11. High Ki-67 score is indicative of a greater benefit from adjuvant chemotherapy when added to endocrine therapy in luminal B HER2 negative and node-positive breast cancer.

    Science.gov (United States)

    Criscitiello, Carmen; Disalvatore, Davide; De Laurentiis, Michele; Gelao, Lucia; Fumagalli, Luca; Locatelli, Marzia; Bagnardi, Vincenzo; Rotmensz, Nicole; Esposito, Angela; Minchella, Ida; De Placido, Sabino; Santangelo, Michele; Viale, Giuseppe; Goldhirsch, Aron; Curigliano, Giuseppe

    2014-02-01

    The indication of adjuvant chemotherapy for patients with highly proliferative estrogen receptor-positive breast cancer is controversial. We analyzed the predictive value of Ki67 for the efficacy of adjuvant chemotherapy in patients with estrogen receptor-positive, node-positive breast cancer. We identified 1241 patients with Luminal B early stage breast cancer with 1-3 axillary positive nodes who underwent surgery between 1995 and 2005 at the European Institute of Oncology and received adjuvant hormonotherapy and/or chemotherapy. Differences in the distribution of characteristics according to treatment were evaluated by the Chi-square test. To evaluate the effect of adding chemotherapy to hormonotherapy, the propensity score method was used to match patients' characteristics minimizing bias related to the non-random assignment of treatment. The probability of receiving chemotherapy was significantly associated with age, tumor grade, degree of hormone responsiveness, tumor size and peripheral vascular invasion. The propensity score distribution was statistically different between the two treatment groups (p chemotherapy group (log-rank test p-value 0.663). The 5-year DFS percentages were 84.6% (95% CI, 81.0-87.6%) in the hormonotherapy group and 84.2% (95% CI, 81.3-86.7%) in the hormonotherapy/chemotherapy group (log-rank test p-value 0.388). However, when analyzing the 5-year DFS by Ki-67 distribution, Subpopulation Treatment Effect Pattern Plot (STEPP) analysis showed a beneficial effect of chemotherapy in patients with highly proliferative tumor (Ki-67 ≥ 32%). The interaction between Ki-67 and treatment was statistically significant (p = 0.027). Ki67 expression identifies a subset of patients with Luminal B and node-positive breast cancer who could benefit from addition of adjuvant chemotherapy to hormonotherapy. Dichotomy was observed for Ki67 at 32% level. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Closing the mind's eye: incoming luminance signals disrupt visual imagery.

    Directory of Open Access Journals (Sweden)

    Rachel Sherwood

    Full Text Available Mental imagery has been associated with many cognitive functions, both high and low-level. Despite recent scientific advances, the contextual and environmental conditions that most affect the mechanisms of visual imagery remain unclear. It has been previously shown that the greater the level of background luminance the weaker the effect of imagery on subsequent perception. However, in these experiments it was unclear whether the luminance was affecting imagery generation or storage of a memory trace. Here, we report that background luminance can attenuate both mental imagery generation and imagery storage during an unrelated cognitive task. However, imagery generation was more sensitive to the degree of luminance. In addition, we show that these findings were not due to differential dark adaptation. These results suggest that afferent visual signals can interfere with both the formation and priming-memory effects associated with visual imagery. It follows that background luminance may be a valuable tool for investigating imagery and its role in various cognitive and sensory processes.

  13. High power green lasers for gamma source

    Science.gov (United States)

    Durand, Magali; Sevillano, Pierre; Alexaline, Olivier; Sangla, Damien; Casanova, Alexis; Aubourg, Adrien; Saci, Abdelhak; Courjaud, Antoine

    2018-02-01

    A high intensity Gamma source is required for Nuclear Spectroscopy, it will be delivered by the interaction between accelerated electron and intense laser beams. Those two interactions lasers are based on a multi-stage amplification scheme that ended with a second harmonics generation to deliver 200 mJ, 5 ps pulses at 515 nm and 100 Hz. A t-Pulse oscillator with slow and fast feedback loop implemented inside the oscillator cavity allows the possibility of synchronization to an optical reference. A temporal jitter of 120 fs rms is achieved, integrated from 10 Hz to 10 MHz. Then a regenerative amplifier, based on Yb:YAG technology, pumped by fiber-coupled QCW laser diodes, delivers pulses up to 30 mJ. The 1 nm bandwidth was compressed to 1.5 ps with a good spatial quality: M2 of 1.1. This amplifier is integrated in a compact sealed housing (750 x 500 x 150 mm), which allows a pulse-pulse stability of 0.1 % rms, and a long-term stability of 1,9 % over 100 hours (with +/-1°C environment). The main amplification stage uses a cryocooled Yb:YAG crystal in an active mirror configuration. The crystal is cooled at 130 K via a compact and low-vibration cryocooler, avoiding any additional phase noise contribution, 340 mJ in a six pass scheme was achieved, with 0.9 of Strehl ratio. The trade off to the gain of a cryogenic amplifier is the bandwidth reduction, however the 1030 nm pulse was compressed to 4.4 ps. As for the regenerative amplifier a long-term stability of 1.9 % over 30 hours was achieved in an environment with +/-1°C temperature fluctuations The compression and Second Harmonics Generation Stages have allowed the conversion of 150 mJ of uncompressed infrared beam into 60 mJ at 515 nm.

  14. Grain formation in the expanding gas flow around cool luminous stars

    International Nuclear Information System (INIS)

    Hasegawa, H.

    1984-01-01

    The existence of solid particles in interstellar space has been revealed by the extinction of starlight in UV, visible and IR. The important sources of interstellar grains are considered to be cool luminous mass loss stars. (author)

  15. Recycled Thermal Energy from High Power Light Emitting Diode Light Source.

    Science.gov (United States)

    Ji, Jae-Hoon; Jo, GaeHun; Ha, Jae-Geun; Koo, Sang-Mo; Kamiko, Masao; Hong, JunHee; Koh, Jung-Hyuk

    2018-09-01

    In this research, the recycled electrical energy from wasted thermal energy in high power Light Emitting Diode (LED) system will be investigated. The luminous efficiency of lights has been improved in recent years by employing the high power LED system, therefore energy efficiency was improved compared with that of typical lighting sources. To increase energy efficiency of high power LED system further, wasted thermal energy should be re-considered. Therefore, wasted thermal energy was collected and re-used them as electrical energy. The increased electrical efficiency of high power LED devices was accomplished by considering the recycled heat energy, which is wasted thermal energy from the LED. In this work, increased electrical efficiency will be considered and investigated by employing the high power LED system, which has high thermal loss during the operating time. For this research, well designed thermoelement with heat radiation system was employed to enhance the collecting thermal energy from the LED system, and then convert it as recycled electrical energy.

  16. Geometry of illumination, luminance contrast, and gloss perception.

    Science.gov (United States)

    Leloup, Frédéric B; Pointer, Michael R; Dutré, Philip; Hanselaer, Peter

    2010-09-01

    The influence of both the geometry of illumination and luminance contrast on gloss perception has been examined using the method of paired comparison. Six achromatic glass samples having different lightness were illuminated by two light sources. Only one of these light sources was visible in reflection by the observer. By separate adjustment of the intensity of both light sources, the luminance of both the reflected image and the adjacent off-specular surroundings could be individually varied. It was found that visual gloss appraisal did not correlate with instrumentally measured specular gloss; however, psychometric contrast seemed to be a much better correlate. It has become clear that not only the sample surface characteristics determine gloss perception: the illumination geometry could be an even more important factor.

  17. Total molecular gas masses of Planck - Herschel selected strongly lensed hyper luminous infrared galaxies

    Science.gov (United States)

    Harrington, K. C.; Yun, M. S.; Magnelli, B.; Frayer, D. T.; Karim, A.; Weiß, A.; Riechers, D.; Jiménez-Andrade, E. F.; Berman, D.; Lowenthal, J.; Bertoldi, F.

    2018-03-01

    We report the detection of CO(1-0) line emission from seven Planck and Herschel selected hyper luminous ({L_{IR (8-1000{μ m})} > 10^{13} L_{⊙}) infrared galaxies with the Green Bank Telescope (GBT). CO(1-0) measurements are a vital tool to trace the bulk molecular gas mass across all redshifts. Our results place tight constraints on the total gas content of these most apparently luminous high-z star-forming galaxies (apparent IR luminosities of LIR > 1013 - 14 L⊙), while we confirm their predetermined redshifts measured using the Large Millimeter Telescope, LMT (zCO = 1.33-3.26). The CO(1-0) lines show similar profiles as compared to Jup = 2-4 transitions previously observed with the LMT. We report enhanced infrared to CO line luminosity ratios of = 110 ± 22 L_{⊙} (K km s^{-1} pc^{-2})^{-1} compared to normal star-forming galaxies, yet similar to those of well-studied IR-luminous galaxies at high-z. We find average brightness temperature ratios of 〈 r21〉 = 0.93 (2 sources), 〈 r31〉 = 0.34 (5 sources), and 〈 r41〉 = 0.18 (1 source). The r31 and r41 values are roughly half the average values for SMGs. We estimate the total gas mass content as {μ M_{H2} = (0.9-27.2) × 10^{11} (α _CO/0.8) M_{⊙}, where μ is the magnification factor and αCO is the CO line luminosity to molecular hydrogen gas mass conversion factor. The rapid gas depletion times, = 80} Myr, reveal vigorous starburst activity, and contrast the Gyr depletion time-scales observed in local, normal star-forming galaxies.

  18. Proton and Ion Sources for High Intensity Accelerators

    CERN Multimedia

    Scrivens, R

    2004-01-01

    Future high intensity ion accelerators, including the Spallation Neutron Source (SNS), the European Spallation Source (ESS), the Superconducting Proton Linac (SPL) etc, will require high current and high duty factor sources for protons and negative hydrogen ions. In order to achieve these goals, a comparison of the Electron Cyclotron Resonance, radio-frequency and Penning ion sources, among others, will be made. For each of these source types, the present operational sources will be compared to the state-of-the-art research devices with special attention given to reliability and availability. Finally, the future research and development aims will be discussed.

  19. High dose rate brachytherapy source measurement intercomparison.

    Science.gov (United States)

    Poder, Joel; Smith, Ryan L; Shelton, Nikki; Whitaker, May; Butler, Duncan; Haworth, Annette

    2017-06-01

    This work presents a comparison of air kerma rate (AKR) measurements performed by multiple radiotherapy centres for a single HDR 192 Ir source. Two separate groups (consisting of 15 centres) performed AKR measurements at one of two host centres in Australia. Each group travelled to one of the host centres and measured the AKR of a single 192 Ir source using their own equipment and local protocols. Results were compared to the 192 Ir source calibration certificate provided by the manufacturer by means of a ratio of measured to certified AKR. The comparisons showed remarkably consistent results with the maximum deviation in measurement from the decay-corrected source certificate value being 1.1%. The maximum percentage difference between any two measurements was less than 2%. The comparisons demonstrated the consistency of well-chambers used for 192 Ir AKR measurements in Australia, despite the lack of a local calibration service, and served as a valuable focal point for the exchange of ideas and dosimetry methods.

  20. Studies of IRAS sources at high galactic latitudes

    International Nuclear Information System (INIS)

    Rowan-Robinson, M.; Helou, G.; Walker, D.

    1987-01-01

    A detailed study has been carried out of a complete sample of IRAS 25-, 60- and 100-μm sources identified with galaxies brighter than 14.5 mag at b > 60 0 . Redshifts are available for virtually all these galaxies. The 60- and 100-μm luminosities are well correlated with the corrected absolute magnitude Msub(B), the 25-μm luminosity less well so. There is a clear correlation of the ratio of far-infrared luminosity to optical luminosity, Lsub(FIR)/Lsub(B), with 100 μm/60 μm colour, in the sense that the more luminous infrared galaxies are warmer. This behaviour can be modelled as a mixture of a normal 'disc' component and a starburst component. There is no significant difference in the distribution of Lsub(FIR)/Lsub(B) versus 100 μm/60 μm colour for edge-on and face-on spirals, showing that the adopted internal extinction correction is a good approximation. (author)

  1. Quantum Entanglement and High Brightness Laser Source

    Data.gov (United States)

    National Aeronautics and Space Administration — Our focus is on demonstrating high precision (sub-micron) laser ranging for Navigation using a unique high-sensitivity optical correlation receiver with both...

  2. Comparison of clinical outcomes between luminal invasive ductal carcinoma and luminal invasive lobular carcinoma

    International Nuclear Information System (INIS)

    Adachi, Yayoi; Ishiguro, Junko; Kotani, Haruru; Hisada, Tomoka; Ichikawa, Mari; Gondo, Naomi; Yoshimura, Akiyo; Kondo, Naoto; Hattori, Masaya; Sawaki, Masataka; Fujita, Takashi; Kikumori, Toyone; Yatabe, Yasushi; Kodera, Yasuhiro; Iwata, Hiroji

    2016-01-01

    The pathological and clinical features of invasive lobular carcinoma (ILC) differ from those of invasive ductal carcinoma (IDC). Several studies have indicated that patients with ILC have a better prognosis than those with ductal carcinoma. However, no previous study has considered the molecular subtypes and histological subtypes of ILC. We compared prognosis between IDC and classical, luminal type ILC and developed prognostic factors for early breast cancer patients with classical luminal ILC. Four thousand one hundred ten breast cancer patients were treated at the Aichi Cancer Center Hospital from 2003 to 2012. We identified 1,661 cases with luminal IDC and 105 cases with luminal classical ILC. We examined baseline characteristics, clinical outcomes, and prognostic factors of luminal ILC. The prognosis of luminal ILC was significantly worse than that of luminal IDC. The rates of 5-year disease free survival (DFS) were 91.9 % and 88.4 % for patients with luminal IDC and luminal ILC, respectively (P = 0.008). The rates of 5-year overall survival (OS) were 97.6 % and 93.1 % for patients with luminal IDC and luminal ILC respectively (P = 0.030). Although we analyzed prognosis according to stratification by tumor size, luminal ILC tended to have worse DFS than luminal IDC in the large tumor group. In addition, although our analysis was performed according to matching lymph node status, luminal ILC had a significantly worse DFS and OS than luminal IDC in node-positive patients. Survival curves showed that the prognosis for ILC became worse than IDC over time. Multivariate analysis showed that ILC was an important factor related to higher risk of recurrence of luminal type breast cancer, even when tumor size, lymph node status and histological grade were considered. Luminal ILC had worse outcomes than luminal IDC. Consequently, different treatment approaches should be used for luminal ILC than for luminal IDC. The online version of this article (doi:10.1186/s12885

  3. THE MOST LUMINOUS GALAXIES DISCOVERED BY WISE

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, Chao-Wei; Eisenhardt, Peter R. M.; Stern, Daniel; Moustakas, Leonidas A. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Dr., Pasadena, CA 91109 (United States); Wu, Jingwen; Wright, Edward L. [Department of Physics and Astronomy, UCLA, Los Angeles, CA 90095-1547 (United States); Assef, Roberto J. [Núcleo de Astronomía de la Facultad deIngeniería, Universidad Diego Portales, Av. Ejército Libertador 441, Santiago (Chile); Blain, Andrew W. [Department of Physics and Astronomy, University of Leicester, 1 University Road, Leicester, LE1 7RH (United Kingdom); Bridge, Carrie R.; Sayers, Jack [Division of Physics, Math, and Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); Benford, Dominic J.; Leisawitz, David T. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Cutri, Roc M.; Masci, Frank J.; Yan, Lin [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Griffith, Roger L. [Department of Astronomy and Astrophysics, The Pennsylvania State University, 525 Davey Lab, University Park, PA 16802 (United States); Jarrett, Thomas H. [Astronomy Department, University of Cape Town, Private Bag X3, Rondebosch 7701 (South Africa); Lonsdale, Carol J. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Petty, Sara M. [Department of Physics, Virginia Tech, Blacksburg, VA 24061 (United States); Stanford, S. Adam, E-mail: Chao-Wei.Tsai@jpl.nasa.gov [Department of Physics, University of California Davis, One Shields Avenue, Davis, CA 95616 (United States); and others

    2015-06-01

    We present 20 Wide-field Infrared Survey Explorer (WISE)-selected galaxies with bolometric luminosities L{sub bol} > 10{sup 14} L{sub ☉}, including five with infrared luminosities L{sub IR} ≡ L{sub (rest} {sub 8–1000} {sub μm)} > 10{sup 14} L{sub ☉}. These “extremely luminous infrared galaxies,” or ELIRGs, were discovered using the “W1W2-dropout” selection criteria which requires marginal or non-detections at 3.4 and 4.6 μm (W1 and W2, respectively) but strong detections at 12 and 22 μm in the WISE survey. Their spectral energy distributions are dominated by emission at rest-frame 4–10 μm, suggesting that hot dust with T{sub d} ∼ 450 K is responsible for the high luminosities. These galaxies are likely powered by highly obscured active galactic nuclei (AGNs), and there is no evidence suggesting these systems are beamed or lensed. We compare this WISE-selected sample with 116 optically selected quasars that reach the same L{sub bol} level, corresponding to the most luminous unobscured quasars in the literature. We find that the rest-frame 5.8 and 7.8 μm luminosities of the WISE-selected ELIRGs can be 30%–80% higher than that of the unobscured quasars. The existence of AGNs with L{sub bol} > 10{sup 14} L{sub ☉} at z > 3 suggests that these supermassive black holes are born with large mass, or have very rapid mass assembly. For black hole seed masses ∼10{sup 3} M{sub ☉}, either sustained super-Eddington accretion is needed, or the radiative efficiency must be <15%, implying a black hole with slow spin, possibly due to chaotic accretion.

  4. Night sky luminance under clear sky conditions: Theory vs. experiment

    International Nuclear Information System (INIS)

    Kocifaj, Miroslav

    2014-01-01

    Sky glow is caused by both natural phenomena and factors of anthropogenic origin, and of the latter ground-based light sources are the most important contributors for they emit the spatially linked spectral radiant intensity distribution of artificial light sources, which are further modulated by local atmospheric optics and perceived as the diffuse light of a night sky. In other words, sky glow is closely related to a city's shape and pattern of luminaire distribution, in practical effect an almost arbitrary deployment of random orientation of heterogeneous electrical light sources. Thus the luminance gradation function measured in a suburban zone or near the edges of a city is linked to the City Pattern or vice versa. It is shown that clear sky luminance/radiance data recorded in an urban area can be used to retrieve the bulk luminous/radiant intensity distribution if some a-priori information on atmospheric aerosols is available. For instance, the single scattering albedo of aerosol particles is required under low turbidity conditions, as demonstrated on a targeted experiment in the city of Frýdek-Mistek. One of the main advantages of the retrieval method presented in this paper is that the single scattering approximation is satisfactorily accurate in characterizing the light field near the ground because the dominant contribution to the sky glow has originated from beams propagated along short optical paths. - Highlights: • Urban sky glow is interpreted in terms of city emission function. • Luminance function in a suburban zone is linked to the City Pattern. • Single scattering approximation is applicable in modeling urban sky glow. • Information on aerosols represents valuable inputs to the retrieval procedure. • Sky glow patterns vary with light source distribution and spectral emission

  5. Enigmatic sub-luminous accreting neutron stars in our Galaxy

    NARCIS (Netherlands)

    Wijnands, R.

    2008-01-01

    During the last few years a class of enigmatic sub-luminous accreting neutron stars has been found in our Galaxy. They have peak X-ray luminosities (2-10 keV) of a few times 10(34) erg s(−1) to a few times 10(35) erg s(−1), and both persistent and transient sources have been found. I present a short

  6. Scintillation camera for high activity sources

    International Nuclear Information System (INIS)

    Arseneau, R.E.

    1978-01-01

    The invention described relates to a scintillation camera used for clinical medical diagnosis. Advanced recognition of many unacceptable pulses allows the scintillation camera to discard such pulses at an early stage in processing. This frees the camera to process a greater number of pulses of interest within a given period of time. Temporary buffer storage allows the camera to accommodate pulses received at a rate in excess of its maximum rated capability due to statistical fluctuations in the level of radioactivity of the radiation source measured. (U.K.)

  7. A LUMINOUS GAMMA-RAY BINARY IN THE LARGE MAGELLANIC CLOUD

    Energy Technology Data Exchange (ETDEWEB)

    Corbet, R. H. D. [University of Maryland, Baltimore County, and X-ray Astrophysics Laboratory, Code 662 NASA Goddard Space Flight Center, Greenbelt Rd., MD 20771 (United States); Chomiuk, L.; Strader, J. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Coe, M. J. [University of Southampton, School of Physics and Astronomy, Southampton SO17 1BJ (United Kingdom); Coley, J. B. [NASA Postdoctoral Program, and Astroparticle Physics Laboratory, Code 661 NASA Goddard Space Flight Center, Greenbelt Rd., MD 20771 (United States); Dubus, G. [Institut de Planétologie et d’Astrophysique de Grenoble, Univ. Grenoble Alpes, CNRS, F-38000 Grenoble (France); Edwards, P. G.; Stevens, J. [Commonwealth Scientific and Industrial Research Organisation Astronomy and Space Science, P.O. Box 76, Epping, New South Wales 1710 (Australia); Martin, P. [Institut de Recherche en Astrophysique et Planétologie, Université de Toulouse, CNRS, F-31028 Toulouse cedex 4 (France); McBride, V. A.; Townsend, L. J. [Department of Astronomy, University of Cape Town, Private Bag X3, Rondebosch 7701 (South Africa); Udalski, A. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland)

    2016-10-01

    Gamma-ray binaries consist of a neutron star or a black hole interacting with a normal star to produce gamma-ray emission that dominates the radiative output of the system. Only a handful of such systems have been previously discovered, all within our Galaxy. Here, we report the discovery of a luminous gamma-ray binary in the Large Magellanic Cloud, found with the Fermi Large Area Telescope (LAT), from a search for periodic modulation in all sources in the third Fermi LAT catalog. This is the first such system to be found outside the Milky Way. The system has an orbital period of 10.3 days, and is associated with a massive O5III star located in the supernova remnant DEM L241, previously identified as the candidate high-mass X-ray binary (HMXB) CXOU J053600.0–673507. X-ray and radio emission are also modulated on the 10.3 day period, but are in anti-phase with the gamma-ray modulation. Optical radial velocity measurements suggest that the system contains a neutron star. The source is significantly more luminous than similar sources in the Milky Way, at radio, optical, X-ray, and gamma-ray wavelengths. The detection of this extra-galactic system, but no new Galactic systems, raises the possibility that the predicted number of gamma-ray binaries in our Galaxy has been overestimated, and that HMXBs may be born containing relatively slowly rotating neutron stars.

  8. High-power laser source evaluation

    International Nuclear Information System (INIS)

    Back, C.A.; Decker, C.D.; Dipeso, G.J.; Gerassimenko, M.; Managan, R.A.; Serduke, F.J.D.; Simonson, G.F.; Suter, L.J.

    1997-07-01

    This document reports progress in these areas: EXPERIMENTAL RESULTS FROM NOVA: TAMPED XENON UNDERDENSE X-RAY EMITTERS; MODELING MULTI-KEV RADIATION PRODUCTION OF XENON-FILLED BERYLLIUM CANS; MAPPING A CALCULATION FROM LASNEX TO CALE; HOT X RAYS FROM SEEDED NIF CAPSULES; HOHLRAUM DEBRIS MEASUREMENTS AT NOVA; FOAM AND STRUCTURAL RESPONSE CALCULATIONS FOR NIF NEUTRON EXPOSURE SAMPLE CASE ASSEMBLY DESIGN; NON-IGNITION X-RAY SOURCE FLUENCE-AREA PRODUCTS FOR NUCLEAR EFFECTS TESTING ON NIF. Also appended are reprints of two papers. The first is on the subject of ''X-Ray Production in Laser-Heated Xe Gas Targets.'' The second is on ''Efficient Production and Applications of 2- to 10-keV X Rays by Laser-Heated Underdense Radiators.''

  9. SPECTRAL AND SPATIAL SELECTIVITY OF LUMINANCE VISION IN REEF FISH

    Directory of Open Access Journals (Sweden)

    Ulrike E Siebeck

    2014-09-01

    Full Text Available Luminance vision has high spatial resolution and is used for form vision and texture discrimination. In humans, birds and bees luminance channel is spectrally selective – it depends on the signals of the long-wavelength sensitive photoreceptors (bees or on the sum of long- and middle- wavelength sensitive cones (humans, but not on the signal of the short-wavelength sensitive (blue photoreceptors. The reasons of such selectivity are not fully understood. The aim of this study is to reveal the inputs of cone signals to high resolution luminance vision in reef fish. 16 freshly caught damselfish, Pomacentrus amboinensis, were trained to discriminate stimuli differing either in their colour or in their fine patterns (stripes vs. cheques. Three colours (‘bright green’, ‘dark green’ and ‘blue’ were used to create two sets of colour and two sets of pattern stimuli. The ‘bright green’ and ‘dark green’ were similar in their chromatic properties for fish, but differed in their lightness; the ‘dark green’ differed from ‘blue’ in the signal for the blue cone, but yielded similar signals in the long-wavelength and middle-wavelength cones. Fish easily learned to discriminate ‘bright green’ from ‘dark green’ and ‘dark green’ from ‘blue’ stimuli. Fish also could discriminate the fine patterns created from ‘dark green’ and ‘bright green’. However, fish failed to discriminate fine patterns created from ‘blue’ and ‘dark green’ colours, i.e. the colours that provided contrast for the blue-sensitive photoreceptor, but not for the long-wavelength sensitive one. High resolution luminance vision in damselfish, Pomacentrus amboinensis, does not have input from the blue-sensitive cone, which may indicate that the spectral selectivity of luminance channel is a general feature of visual processing in both aquatic and terrestrial animals.

  10. Reproducibility of airway luminal size in asthma measured by HRCT.

    Science.gov (United States)

    Brown, Robert H; Henderson, Robert J; Sugar, Elizabeth A; Holbrook, Janet T; Wise, Robert A

    2017-10-01

    Brown RH, Henderson RJ, Sugar EA, Holbrook JT, Wise RA, on behalf of the American Lung Association Airways Clinical Research Centers. Reproducibility of airway luminal size in asthma measured by HRCT. J Appl Physiol 123: 876-883, 2017. First published July 13, 2017; doi:10.1152/japplphysiol.00307.2017.-High-resolution CT (HRCT) is a well-established imaging technology used to measure lung and airway morphology in vivo. However, there is a surprising lack of studies examining HRCT reproducibility. The CPAP Trial was a multicenter, randomized, three-parallel-arm, sham-controlled 12-wk clinical trial to assess the use of a nocturnal continuous positive airway pressure (CPAP) device on airway reactivity to methacholine. The lack of a treatment effect of CPAP on clinical or HRCT measures provided an opportunity for the current analysis. We assessed the reproducibility of HRCT imaging over 12 wk. Intraclass correlation coefficients (ICCs) were calculated for individual airway segments, individual lung lobes, both lungs, and air trapping. The ICC [95% confidence interval (CI)] for airway luminal size at total lung capacity ranged from 0.95 (0.91, 0.97) to 0.47 (0.27, 0.69). The ICC (95% CI) for airway luminal size at functional residual capacity ranged from 0.91 (0.85, 0.95) to 0.32 (0.11, 0.65). The ICC measurements for airway distensibility index and wall thickness were lower, ranging from poor (0.08) to moderate (0.63) agreement. The ICC for air trapping at functional residual capacity was 0.89 (0.81, 0.94) and varied only modestly by lobe from 0.76 (0.61, 0.87) to 0.95 (0.92, 0.97). In stable well-controlled asthmatic subjects, it is possible to reproducibly image unstimulated airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. NEW & NOTEWORTHY There is a surprising lack

  11. High-Current Plasma Electron Sources

    International Nuclear Information System (INIS)

    Gushenets, J.Z.; Krokhmal, V.A.; Krasik, Ya. E.; Felsteiner, J.; Gushenets, V.

    2002-01-01

    In this report we present the design, electrical schemes and preliminary results of a test of 4 different electron plasma cathodes operating under Kg h-voltage pulses in a vacuum diode. The first plasma cathode consists of 6 azimuthally symmetrically distributed arc guns and a hollow anode having an output window covered by a metal grid. Plasma formation is initiated by a surface discharge over a ceramic washer placed between a W-made cathode and an intermediate electrode. Further plasma expansion leads to a redistribution of the discharge between the W-cathode and the hollow anode. An accelerating pulse applied between the output anode grid and the collector extracts electrons from this plasma. The operation of another plasma cathode design is based on Penning discharge for preliminary plasma formation. The main glow discharge occurs between an intermediate electrode of the Penning gun and the hollow anode. To keep the background pressure in the accelerating gap at P S 2.5x10 4 Torr either differential pumping or a pulsed gas puff valve were used. The operation of the latter electron plasma source is based on a hollow cathode discharge. To achieve a sharp pressure gradient between the cathode cavity and the accelerating gap a pulsed gas puff valve was used. A specially designed ferroelectric plasma cathode initiated plasma formation inside the hollow cathode. This type of the hollow cathode discharge ignition allowed to achieve a discharge current of 1.2 kA at a background pressure of 2x10 4 Torr. All these cathodes were developed and initially tested inside a planar diode with a background pressure S 2x10 4 Torr under the same conditions: accelerating voltage 180 - 300 kV, pulse duration 200 - 400 ns, electron beam current - 1 - 1.5 kA, and cross-sectional area of the extracted electron beam 113 cm 2

  12. Characteristics of a High Current Helicon Ion Source With High Monatomic Fraction

    International Nuclear Information System (INIS)

    Jung, Hwa-Dong; Chung, Kyoung-Jae; Hwang, Yong-Seok

    2006-01-01

    Applications of neutron need compact and high yield neutron sources as well as very intense neutron sources from giant devices such as accelerators. Ion source based neutron sources using nuclear fusion reactions such as D(d, 3He)n, D(t, 4He)n can meet the requirements. This type of neutron generators can be simply composed of an ion source and a target. High-performance neutron generators with high yield require ion sources with high beam current, high monatomic fraction and long lifetime. Helicon ion source can meet these requirements. To make high current ion source, characteristics of helicon plasma such as high plasma density can be utilized. Moreover, efficient plasma heating with RF power lead high fraction of monatomic ion beam. Here, Characteristics of helicon plasma sources are described. Design and its performances of a helicon ion source are presented

  13. EUV source development for high-volume chip manufacturing tools

    Science.gov (United States)

    Stamm, Uwe; Yoshioka, Masaki; Kleinschmidt, Jürgen; Ziener, Christian; Schriever, Guido; Schürmann, Max C.; Hergenhan, Guido; Borisov, Vladimir M.

    2007-03-01

    Xenon-fueled gas discharge produced plasma (DPP) sources were integrated into Micro Exposure Tools already in 2004. Operation of these tools in a research environment gave early learning for the development of EUV sources for Alpha and Beta-Tools. Further experiments with these sources were performed for basic understanding on EUV source technology and limits, especially the achievable power and reliability. The intermediate focus power of Alpha-Tool sources under development is measured to values above 10 W. Debris mitigation schemes were successfully integrated into the sources leading to reasonable collector mirror lifetimes with target of 10 billion pulses due to the effective debris flux reduction. Source collector mirrors, which withstand the radiation and temperature load of Xenon-fueled sources, have been developed in cooperation with MediaLario Technologies to support intermediate focus power well above 10 W. To fulfill the requirements for High Volume chip Manufacturing (HVM) applications, a new concept for HVM EUV sources with higher efficiency has been developed at XTREME technologies. The discharge produced plasma (DPP) source concept combines the use of rotating disk electrodes (RDE) with laser exited droplet targets. The source concept is called laser assisted droplet RDE source. The fuel of these sources has been selected to be Tin. The conversion efficiency achieved with the laser assisted droplet RDE source is 2-3x higher compared to Xenon. Very high pulse energies well above 200 mJ / 2π sr have been measured with first prototypes of the laser assisted droplet RDE source. If it is possible to maintain these high pulse energies at higher repetition rates a 10 kHz EUV source could deliver 2000 W / 2π sr. According to the first experimental data the new concept is expected to be scalable to an intermediate focus power on the 300 W level.

  14. A High Reliability Frequency Stabilized Semiconductor Laser Source, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Ultrastable, narrow linewidth, high reliability MOPA sources are needed for high performance LIDARs in NASA for, wind speed measurement, surface topography and earth...

  15. Daylight calculations using constant luminance curves

    Energy Technology Data Exchange (ETDEWEB)

    Betman, E. [CRICYT, Mendoza (Argentina). Laboratorio de Ambiente Humano y Vivienda

    2005-02-01

    This paper presents a simple method to manually estimate daylight availability and to make daylight calculations using constant luminance curves calculated with local illuminance and irradiance data and the all-weather model for sky luminance distribution developed in the Atmospheric Science Research Center of the University of New York (ARSC) by Richard Perez et al. Work with constant luminance curves has the advantage that daylight calculations include the problem's directionality and preserve the information of the luminous climate of the place. This permits accurate knowledge of the resource and a strong basis to establish conclusions concerning topics related to the energy efficiency and comfort in buildings. The characteristics of the proposed method are compared with the method that uses the daylight factor. (author)

  16. NCOA5 is correlated with progression and prognosis in luminal breast cancer

    International Nuclear Information System (INIS)

    Ye, Xiao-He; Huang, Du-Ping; Luo, Rong-Cheng

    2017-01-01

    Nuclear receptor coactivator 5 (NCOA5) is known to modulate ERα-mediated transcription and has been found to be involved in the progression of several malignancies. However, the potential correlation between NCOA5 and clinical outcome in patients with luminal breast cancer remains unknown. In the present study, we demonstrated that NCOA5 was significantly up-regulated in luminal breast cancer tissues compared with adjacent non-cancerous tissues both in validated cohort and TCGA cohort. Moreover, Kaplan-Meier analysis indicated that patients with high NOCA5 expression had significantly lower overall survival (P = 0.021). Cox regression analysis indicated that the high NOCA5 expression was independent high risk factor as well as old age (>60) and HER-2 expression (P = 0.039; P = 0.003; P = 0.005; respectively). This study provides new insights and evidences that NOCA5 over-expression was significantly correlated with progression and prognosis in luminal breast cancer. However, the precise cellular mechanisms for NOCA5 in luminal breast cancer need to be further explored. - Highlights: • NCOA5 is significantly over-expressed in human luminal breast cancer tissues. • NOCA5 was involved in the progression of luminal breast cancer. • NCOA5 can predict the progression of luminal breast cancer.

  17. Improvement of highly charged ion output from an ECR source

    International Nuclear Information System (INIS)

    Shirkov, G.D.

    1995-01-01

    The physical limitations of the highly charged ion production in the ECR source is analyzed in this report. General methods to increase the output ion current and the attainable charged states of heavy ions are discussed. Some new ways to improve the output of highly charged ions from the ECR source for heavy ions are proposed. A new library of computer codes for the mathematical simulation of heavy ion production in the ECR ion source is used for numerical experiments to test these ways for improving the operation of the ECR source. (orig.)

  18. Influence of materials in reflection of the high and the luminous quality; Influencia de los materiales en la reflexion de la luz y en la caulidad del espacio lminoso

    Energy Technology Data Exchange (ETDEWEB)

    Piderit, M. B.

    2004-07-01

    This study objective of was to define the aspects of the surfaces and the materials that influence in the reflection of the light and the luminous quality of the architectonic space, to generate a tool of application to the architecture project. In the first part, a study is made of different surfaces to define photometric aspects and qualitative aspects for the typologies elaboration . The following stage included the analysis of different materials to establish the aspects that modify the photometry of the surface and the luminous quality. The conclusions show the importance of the correct election of the type of surface and materiality to obtain the wished luminosity. (Author)

  19. Simultaneous chromatic and luminance human electroretinogram responses.

    Science.gov (United States)

    Parry, Neil R A; Murray, Ian J; Panorgias, Athanasios; McKeefry, Declan J; Lee, Barry B; Kremers, Jan

    2012-07-01

    The parallel processing of information forms an important organisational principle of the primate visual system. Here we describe experiments which use a novel chromatic–achromatic temporal compound stimulus to simultaneously identify colour and luminance specific signals in the human electroretinogram (ERG). Luminance and chromatic components are separated in the stimulus; the luminance modulation has twice the temporal frequency of the chromatic modulation. ERGs were recorded from four trichromatic and two dichromatic subjects (1 deuteranope and 1 protanope). At isoluminance, the fundamental (first harmonic) response was elicited by the chromatic component in the stimulus. The trichromatic ERGs possessed low-pass temporal tuning characteristics, reflecting the activity of parvocellular post-receptoral mechanisms. There was very little first harmonic response in the dichromats' ERGs. The second harmonic response was elicited by the luminance modulation in the compound stimulus and showed, in all subjects, band-pass temporal tuning characteristic of magnocellular activity. Thus it is possible to concurrently elicit ERG responses from the human retina which reflect processing in both chromatic and luminance pathways. As well as providing a clear demonstration of the parallel nature of chromatic and luminance processing in the human retina, the differences that exist between ERGs from trichromatic and dichromatic subjects point to the existence of interactions between afferent post-receptoral pathways that are in operation from the earliest stages of visual processing.

  20. Sources for high frequency heating. Performance and limitations

    International Nuclear Information System (INIS)

    Le Gardeur, R.

    1976-01-01

    The various problems encountered in high frequency heating of plasmas can be decomposed into three spheres of action: theoretical development, antenna designing, and utilization of power sources. By classifying heating into three spectral domains, present and future needs are enumerated. Several specific antenna designs are treated. High frequency power sources are reviewed. The actual development of the gyratron is discussed in view of future needs in very high frequency heating of plasmas [fr

  1. THE XMM-NEWTON X-RAY SPECTRA OF THE MOST X-RAY LUMINOUS RADIO-QUIET ROSAT BRIGHT SURVEY-QSOs: A REFERENCE SAMPLE FOR THE INTERPRETATION OF HIGH-REDSHIFT QSO SPECTRA

    International Nuclear Information System (INIS)

    Krumpe, M.; Markowitz, A.; Lamer, G.; Corral, A.

    2010-01-01

    We present the broadband X-ray properties of four of the most X-ray luminous (L X ≥ 10 45 erg s -1 in the 0.5-2 keV band) radio-quiet QSOs found in the ROSAT Bright Survey. This uniform sample class, which explores the extreme end of the QSO luminosity function, exhibits surprisingly homogenous X-ray spectral properties: a soft excess with an extremely smooth shape containing no obvious discrete features, a hard power law above 2 keV, and a weak narrow/barely resolved Fe Kα fluorescence line for the three high signal-to-noise ratio (S/N) spectra. The soft excess can be well fitted with only a soft power law. No signatures of warm or cold intrinsic absorbers are found. The Fe Kα centroids and the line widths indicate emission from neutral Fe (E = 6.4 keV) originating from cold material from distances of only a few light days or further out. The well-constrained equivalent widths (EW) of the neutral Fe lines are higher than expected from the X-ray Baldwin effect which has been only poorly constrained at very high luminosities. Taking into account our individual EW measurements, we show that the X-ray Baldwin effect flattens above L X ∼ 10 44 erg s -1 (2-10 keV band) where an almost constant (EW) of ∼100 eV is found. We confirm the assumption of having very similar X-ray active galactic nucleus properties when interpreting stacked X-ray spectra. Our stacked spectrum serves as a superb reference for the interpretation of low S/N spectra of radio-quiet QSOs with similar luminosities at higher redshifts routinely detected by XMM-Newton and Chandra surveys.

  2. High-current negative-ion sources for pulsed spallation neutron sources: LBNL workshop, October 1994

    International Nuclear Information System (INIS)

    Alonso, J.R.

    1995-09-01

    The neutron scattering community has endorsed the need for a high-power (1 to 5 MW) accelerator-driven source of neutrons for materials research. Properly configured, the accelerator could produce very short (sub-microsecond) bursts of cold neutrons, said time structure offering advantages over the continuous flux from a reactor. The recent cancellation of the ANS reactor project has increased the urgency to develop a comprehensive strategy based on the best technological scenarios. Studies to date have built on the experience from ISIS (the 160 kW source in the UK), and call for a high-current (approx. 100 mA peak) H- source-linac combination injecting into one or more accumulator rings in which beam may be further accelerated. The I to 5 GeV proton beam is extracted in a single turn and brought to the target-moderator stations. The high current, high duty-factor, high brightness and high reliability required of the ion source present a very large challenge to the ion source community. The Workshop reported on here, held in Berkeley in October 1994, analyzed in detail the source requirements for proposed accelerator scenarios, the present performance capabilities of different H- source technologies, and identified necessary R ampersand D efforts to bridge the gap

  3. A high charge state heavy ion beam source for HIF

    International Nuclear Information System (INIS)

    Eylon, S.; Henestroza, E.

    1995-04-01

    A high current low emittance high charge state heavy ion beam source is being developed. This is designed to deliver HIF (heavy ion fusion) driver accelerator scale beam. Using high-charge-state beam in a driver accelerator for HIF may increase the acceleration efficiency, leading to a reduction in the driver accelerator size and cost. The proposed source system which consists of the gas beam electron stripper followed by a high charge state beam separator, can be added to existing single charge state, low emittance, high brightness ion sources and injectors. We shall report on the source physics design using 2D beam envelope simulations and experimental feasibility studies' results using a neutral gas stripper and a beam separator at the exit of the LBL 2 MV injector

  4. High-efficiency target-ion sources for RIB generation

    International Nuclear Information System (INIS)

    Alton, G.D.

    1993-01-01

    A brief review is given of high-efficiency ion sources which have been developed or are under development at ISOL facilities which show particular promise for use at existing, future, or radioactive ion beam (RIB) facilities now under construction. Emphasis will be placed on those sources which have demonstrated high ionization efficiency, species versatility, and operational reliability and which have been carefully designed for safe handling in the high level radioactivity radiation fields incumbent at such facilities. Brief discussions will also be made of the fundamental processes which affect the realizable beam intensities in target-ion sources. Among the sources which will be reviewed will be selected examples of state-of-the-art electron-beam plasma-type ion sources, thermal-ionization, surface-ionization, ECR, and selectively chosen ion source concepts which show promise for radioactive ion beam generation. A few advanced, chemically selective target-ion sources will be described, such as sources based on the use of laser-resonance ionization, which, in principle, offer a more satisfactory solution to isobaric contamination problems than conventional electromagnetic techniques. Particular attention will be given to the sources which have been selected for initial or future use at the Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory

  5. Source composition of cosmic rays at high energy

    International Nuclear Information System (INIS)

    Juliusson, E.; Cesarsky, C.J.; Meneguzzi, M.; Casse, M.

    1975-01-01

    The source composition of the cosmic ray is usually calculated at an energy of a few GeV per nucleon. Recent measurements have however indicated that the source composition may be energy dependent. In order to give a quantitative answer to this question the source composition at 50GeV/nucleon has been calculated using an exponential distribution of path lengths and in the slab approximation. The results obtained at high energy agree very well with the source composition obtained at lower energies, except the abundance of carbon which is significantly lower than the generally accepted value of low energies [fr

  6. Quantum Communication with a High-Rate Entangled Photon Source

    Science.gov (United States)

    Wilson, Nathaniel C.; Chaffee, Dalton W.; Lekki, John D.; Wilson, Jeffrey D.

    2016-01-01

    A high generation rate photon-pair source using a dual element periodically-poled potassium titanyl phosphate (PP KTP) waveguide is described. The photon-pair source features a high pair generation rate, a compact power-efficient package, and continuous wave (CW) or pulsed operation. Characterization and test results are presented. Details and preliminary results of a laboratory free-space QKD experiment with the B92 protocol are also presented.

  7. ERC sources for the production of highly charged ions (invited)

    International Nuclear Information System (INIS)

    Lyneis, C.M.; Antaya, T.A.

    1990-01-01

    Electron cyclotron resonance ion sources (ECRIS) using rf between 5 and 16 GHz have been developed into stable, reliable sources of highly charged ions produced from a wide range of elements. These devices are currently used as ion sources for cyclotrons, synchrotrons, and heavy-ion linacs for nuclear and relativistic heavy-ion physics. They also serve the atomic physics community as a source of low energy multiply charged ions. In order to improve their performance both with respect to maximum charge state and beam intensity, ECRIS builders are now designing and constructing sources which will operate at frequencies up to 30 GHz. In this article we review the present status of operating ECRIS, review recent experimental measurements on plasma parameters, and look at the technology and potential of sources operating at frequencies up to 30 GHz

  8. High-repetition intra-cavity source of Compton radiation

    International Nuclear Information System (INIS)

    Pogorelsky, I; Polyanskiy, M; Agustsson, R; Campese, T; Murokh, A; Ovodenko, A; Shaftan, T

    2014-01-01

    We report our progress in developing a high-power Compton source for a diversity of applications ranging from university-scale compact x-ray light sources and metrology tools for EUV lithography, to high-brilliance gamma-sources for nuclear analysis. Our conceptual approach lies in multiplying the source’s repetition rate and increasing its average brightness by placing the Compton interaction point inside the optical cavity of an active laser. We discuss considerations in its design, our simulations, and tests of the laser’s cavity that confirm the feasibility of the proposed concept. (paper)

  9. High intensity line source for x-ray spectrometer calibration

    International Nuclear Information System (INIS)

    Thoe, R.S.

    1986-06-01

    A high intensity electron-impact x-ray source using a one-dimensional Pierce lens has been built for the purpose of calibrating a bent crystal x-ray spectrometer. This source focuses up to 100 mA of 20-keV electrons to a line on a liquid-cooled anode. The line (which can serve as a virtual slit for the spectrometer) measures approximately 800 μ x 2 cm. The source is portable and therefore adaptable to numerous types of spectrometer applications. One particular application, the calibration of a high resolution (r = 10 4 ) time-resolved cyrstal spectrometer, will be discussed in detail

  10. Study on the Influence Factors of the Luminous Intensity of the Long Afterglow Luminous Paints

    Directory of Open Access Journals (Sweden)

    Zhao Su

    2016-01-01

    Full Text Available In order to extend the time afterglow luminous powder, enhancement the brightness of luminous paint, this study explore affect long afterglow energy storage luminous paints brightness of the main factors. Luminous paints were prepared with rare earth aluminate long afterglow luminescent powder, first is luminous powder surface modification, then investigate the influence of light emitting powder content, calcium carbonate, titanium dioxide, nano alumina and other fillers on the luminescent properties of the paints. It was concluded that the water resistance of the luminescent powder is better and the brightness can be improved after the modification of anhydrous alcohol. The addition of nano-alumina can improve the brightness of the system, and can effectively enhance the hardness of the paints. In the paints, the two kinds of components of carbonate and titanium dioxide have little effect on the luminescent brightness of the painting.

  11. Relationship between luminous fish and symbiosis. I. Comparative studies of lipopolysaccharides isolated from symbiotic luminous bacteria of the luminous marine fish, Physiculus japonicus.

    Science.gov (United States)

    Kuwae, T; Andoh, M; Fukasawa, S; Kurata, M

    1983-01-01

    In order to investigate the relationship between host and symbiosis in the luminous marine fish, Physiculus japonicus, the bacterial lipopolysaccharides (LPS) of symbiotic luminous bacteria were compared serologically and electrophoretically. Five symbiotic luminous bacteria (PJ strains) were separately isolated from five individuals of this fish species caught at three points, off the coasts of Chiba, Nakaminato, and Oharai. LPS preparations were made from these bacteria by Westphal's phenol-water method and highly purified by repeated ultracentrifugation. These LPSs contained little or no 2-keto-3-deoxyoctonate and had powerful mitogenic activity. In sodium dodecylsulfate polyacrylamide gel electrophoresis, these PJ-1 to -5 LPSs were separated by their electrophoretic patterns into three groups; the first group included PJ-1 and PJ-4, the second group PJ-2 and PJ-3, and the third group PJ-5 alone. The results agreed with those of the double immunodiffusion test; precipitin lines completely coalesced within each group but not with other groups. In immunoelectrophoresis, one precipitin line was observed between anti PJ-2 LPS serum and PJ-5 LPS but the electrophoretic mobility of PJ-5 LPS was clearly different from that of the PJ-2 LPS group. Furthermore, in a 50% inhibition test with PJ-2 LPS by the passive hemolysis system, the doses of PJ-2 LPS, PJ-3 LPS, and PJ-5 LPS required for 50% inhibition (ID50) in this system were 0.25, 0.25, and 21.6 micrograms/ml for each alkali-treated LPS, respectively, and the ID50's of both PJ-1 LPS and PJ-4 LPS were above 1,000 micrograms/ml. These results indicate that PJ-5 LPS has an antigenic determinant partially in common with LPS from the PJ-2 group but not with LPS from the PJ-1 group and that the symbiotic luminous bacterium PJ-5 is more closely related to the PJ-2 group than to the PJ-1 group. These results show that the species Physiculus japonicus is symbiotically associated with at least three immunologically different

  12. Optimal Solution Volume for Luminal Preservation: A Preclinical Study in Porcine Intestinal Preservation.

    Science.gov (United States)

    Oltean, M; Papurica, M; Jiga, L; Hoinoiu, B; Glameanu, C; Bresler, A; Patrut, G; Grigorie, R; Ionac, M; Hellström, M

    2016-03-01

    Rodent studies suggest that luminal solutions alleviate the mucosal injury and prolong intestinal preservation but concerns exist that excessive volumes of luminal fluid may promote tissue edema. Differences in size, structure, and metabolism between rats and humans require studies in large animals before clinical use. Intestinal procurement was performed in 7 pigs. After perfusion with histidine-tryptophan-ketoglutarate (HTK), 40-cm-long segments were cut and filled with 13.5% polyethylene glycol (PEG) 3350 solution as follows: V0 (controls, none), V1 (0.5 mL/cm), V2 (1 mL/cm), V3 (1.5 mL/cm), and V4 (2 mL/cm). Tissue and luminal solutions were sampled after 8, 14, and 24 hours of cold storage (CS). Preservation injury (Chiu score), the apical membrane (ZO-1, brush-border maltase activity), and the electrolyte content in the luminal solution were studied. In control intestines, 8-hour CS in HTK solution resulted in minimal mucosal changes (grade 1) that progressed to significant subepithelial edema (grade 3) by 24 hours. During this time, a gradual loss in ZO-1 was recorded, whereas maltase activity remained unaltered. Moreover, variable degrees of submucosal edema were observed. Luminal introduction of high volumes (2 mL/mL) of PEG solution accelerated the development of the subepithelial edema and submucosal edema, leading to worse histology. However, ZO-1 was preserved better over time than in control intestines (no luminal solution). Maltase activity was reduced in intestines receiving luminal preservation. Luminal sodium content decreased in time and did not differ between groups. This PEG solution protects the apical membrane and the tight-junction proteins but may favor water absorption and tissue (submucosal) edema, and luminal volumes >2 mL/cm may result in worse intestinal morphology. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. High power pulsed sources based on fiber amplifiers

    Science.gov (United States)

    Canat, Guillaume; Jaouën, Yves; Mollier, Jean-Claude; Bouzinac, Jean-Pierre; Cariou, Jean-Pierre

    2017-11-01

    Cladding-pumped rare-earth-doped fiber laser technologies are currently among the best sources for high power applications. Theses extremely compact and robust sources appoint them as good candidate for aeronautical and space applications. The double-clad (DC) fiber converts the poor beamquality of high-power large-area pump diodes from the 1st cladding to laser light at another wavelength guided in an active single-mode core. High-power coherent MOPA (Master Oscillator Power Amplifier) sources (several 10W CW or several 100W in pulsed regime) will soon be achieved. Unfortunately it also brings nonlinear effects which quickly impairs output signal distortions. Stimulated Brillouin scattering (SBS) and optical parametric amplification (OPA) have been shown to be strong limitations. Based on amplifier modeling and experiments we discuss the performances of these sources.

  14. Dynamic encoding of natural luminance sequences by LGN bursts.

    Directory of Open Access Journals (Sweden)

    Nicholas A Lesica

    2006-07-01

    Full Text Available In the lateral geniculate nucleus (LGN of the thalamus, visual stimulation produces two distinct types of responses known as tonic and burst. Due to the dynamics of the T-type Ca(2+ channels involved in burst generation, the type of response evoked by a particular stimulus depends on the resting membrane potential, which is controlled by a network of modulatory connections from other brain areas. In this study, we use simulated responses to natural scene movies to describe how modulatory and stimulus-driven changes in LGN membrane potential interact to determine the luminance sequences that trigger burst responses. We find that at low resting potentials, when the T channels are de-inactivated and bursts are relatively frequent, an excitatory stimulus transient alone is sufficient to evoke a burst. However, to evoke a burst at high resting potentials, when the T channels are inactivated and bursts are relatively rare, prolonged inhibitory stimulation followed by an excitatory transient is required. We also observe evidence of these effects in vivo, where analysis of experimental recordings demonstrates that the luminance sequences that trigger bursts can vary dramatically with the overall burst percentage of the response. To characterize the functional consequences of the effects of resting potential on burst generation, we simulate LGN responses to different luminance sequences at a range of resting potentials with and without a mechanism for generating bursts. Using analysis based on signal detection theory, we show that bursts enhance detection of specific luminance sequences, ranging from the onset of excitatory sequences at low resting potentials to the offset of inhibitory sequences at high resting potentials. These results suggest a dynamic role for burst responses during visual processing that may change according to behavioral state.

  15. Ion source and injection line for high intensity medical cyclotron

    Science.gov (United States)

    Jia, XianLu; Guan, Fengping; Yao, Hongjuan; Zhang, TianJue; Yang, Jianjun; Song, Guofang; Ge, Tao; Qin, Jiuchang

    2014-02-01

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H- ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H- ion source (CIAE-CH-I type) and a short injection line, which the H- ion source of 3 mA/25 keV H- beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

  16. High current vacuum arc ion source for heavy ion fusion

    International Nuclear Information System (INIS)

    Qi, N.; Schein, J.; Gensler, S.; Prasad, R.R.; Krishnan, M.; Brown, I.

    1999-01-01

    Heavy Ion fusion (HIF) is one of the approaches for the controlled thermonuclear power production. A source of heavy ions with charge states 1+ to 2+, in ∼0.5 A current beams with ∼20 micros pulse widths and ∼10 Hz repetition rates are required. Thermionic sources have been the workhorse for the HIF program to date, but suffer from sloe turn-on, heating problems for large areas, are limited to low (contact) ionization potential elements and offer relatively low ion fluxes with a charge state limited to 1+. Gas injection sources suffer from partial ionization and deleterious neutral gas effects. The above shortcomings of the thermionic ion sources can be overcome by a vacuum arc ion source. The vacuum arc ion source is a good candidate for HIF applications. It is capable of providing ions of various elements and different charge states, in short and long pulse bursts, with low emittance and high beam currents. Under a Phase-I STTR from DOE, the feasibility of the vacuum arc ion source for the HIF applications is investigated. An existing ion source at LBNL was modified to produce ∼0.5 A, ∼60 keV Gd (A∼158) ion beams. The experimental effort concentrated on beam noise reduction, pulse-to-pulse reproducibility and achieving low beam emittance at 0.5 A ion current level. Details of the source development will be reported

  17. High-energy diffraction microscopy at the advanced photon source

    DEFF Research Database (Denmark)

    Lienert, U.; Li, S. F.; Hefferan, C. M.

    2011-01-01

    The status of the High Energy Diffraction Microscopy (HEDM) program at the 1-ID beam line of the Advanced Photon Source is reported. HEDM applies high energy synchrotron radiation for the grain and sub-grain scale structural and mechanical characterization of polycrystalline bulk materials in situ...

  18. Pulsed high-current electron source: Final report

    International Nuclear Information System (INIS)

    Spindt, C.A.

    1988-10-01

    The objective of this investigation was to investigate ways to realize the cathode's potential as a source for high power pulse operation. The questions that needed to be studied were those of large area coverage, maximum emission that the cathode arrays are capable of producing practically, uniformity of emission over large areas, and the ability to operate with high voltage anodes. 9 figs

  19. Heavy X-ray obscuration in the most luminous galaxies discovered by WISE

    Science.gov (United States)

    Vito, F.; Brandt, W. N.; Stern, D.; Assef, R. J.; Chen, C.-T. J.; Brightman, M.; Comastri, A.; Eisenhardt, P.; Garmire, G. P.; Hickox, R.; Lansbury, G.; Tsai, C.-W.; Walton, D. J.; Wu, J. W.

    2018-03-01

    Hot dust-obscured galaxies (DOGs) are hyperluminous (L8-1000 μm > 1013 L⊙) infrared galaxies with extremely high (up to hundreds of K) dust temperatures. The sources powering both their extremely high luminosities and dust temperatures are thought to be deeply buried and rapidly accreting supermassive black holes (SMBHs). Hot DOGs could therefore represent a key evolutionary phase in which the SMBH growth peaks. X-ray observations can be used to study their obscuration levels and luminosities. In this work, we present the X-ray properties of the 20 most luminous (Lbol ≳ 1014 L⊙) known hot DOGs at z = 2-4.6. Five of them are covered by long-exposure (10-70 ks) Chandra and XMM-Newton observations, with three being X-ray detected, and we study their individual properties. One of these sources (W0116-0505) is a Compton-thick candidate, with column density NH = (1.0-1.5) × 1024 cm-2 derived from X-ray spectral fitting. The remaining 15 hot DOGs have been targeted by a Chandra snapshot (3.1 ks) survey. None of these 15 are individually detected; therefore, we applied a stacking analysis to investigate their average emission. From hardness ratio analysis, we constrained the average obscuring column density and intrinsic luminosity to be log NH (cm-2) > 23.5 and LX ≳ 1044 erg s-1, which are consistent with results for individually detected sources. We also investigated the LX-L6 μm and LX-Lbol relations, finding hints that hot DOGs are typically X-ray weaker than expected, although larger samples of luminous obscured quasi-stellar objects are needed to derive solid conclusions.

  20. Progress of compact Marx generators high power microwave source

    International Nuclear Information System (INIS)

    Liu Jinliang; Fan Xuliang; Bai Guoqiang; Cheng Xinbing

    2012-01-01

    The compact Marx generators, which can operate at a certain repetition frequency with small size, light weight, and high energy efficiency, are widely used in narrowband, wideband and ultra-wideband high power microwave (HPM) sources. This type of HPM source based on compact Marx generators is a worldwide research focus in recent years, and is important trend of development. The developments of this type of HPM source are described systemically in this paper. The output parameters and structural characteristics are reviewed, and the trends of development are discussed. This work provides reference and evidence for us to master the status of the HPM source based on compact Marx generators correctly and to explore its technical routes scientifically. (authors)

  1. Diagnostic Spectrometers for High Energy Density X-Ray Sources

    International Nuclear Information System (INIS)

    Hudson, L. T.; Henins, A.; Seely, J. F.; Holland, G. E.

    2007-01-01

    A new generation of advanced laser, accelerator, and plasma confinement devices are emerging that are producing extreme states of light and matter that are unprecedented for laboratory study. Examples of such sources that will produce laboratory x-ray emissions with unprecedented characteristics include megajoule-class and ultrafast, ultraintense petawatt laser-produced plasmas; tabletop high-harmonic-generation x-ray sources; high-brightness zeta-pinch and magnetically confined plasma sources; and coherent x-ray free electron lasers and compact inverse-Compton x-ray sources. Characterizing the spectra, time structure, and intensity of x rays emitted by these and other novel sources is critical to assessing system performance and progress as well as pursuing the new and unpredictable physical interactions of interest to basic and applied high-energy-density (HED) science. As these technologies mature, increased emphasis will need to be placed on advanced diagnostic instrumentation and metrology, standard reference data, absolute calibrations and traceability of results.We are actively designing, fabricating, and fielding wavelength-calibrated x-ray spectrometers that have been employed to register spectra from a variety of exotic x-ray sources (electron beam ion trap, electron cyclotron resonance ion source, terawatt pulsed-power-driven accelerator, laser-produced plasmas). These instruments employ a variety of curved-crystal optics, detector technologies, and data acquisition strategies. In anticipation of the trends mentioned above, this paper will focus primarily on optical designs that can accommodate the high background signals produced in HED experiments while also registering their high-energy spectral emissions. In particular, we review the results of recent laboratory testing that explores off-Rowland circle imaging in an effort to reclaim the instrumental resolving power that is increasingly elusive at higher energies when using wavelength

  2. Relationships between luminance and visual acuity in the rhesus monkey

    Science.gov (United States)

    Cavonius, C. R.; Robbins, D. O.

    1973-01-01

    1. The ability of rhesus monkeys to detect the gap in Landolt ring test-objects that were presented against background luminances between 5 × 10-5 cd/m2 and 5 × 103 cd/m2 was compared with similar human data. 2. At high luminance-levels the acuity of human observers is slightly better than that of rhesus, but rhesus have better acuity at scotopic luminance-levels. Both species have distinct photopic and scotopic acuity functions that cross at 6 × 10-3 cd/m2. 3. The threshold for light detection is estimated to be the same for both species when specified in quanta incident on the retina. 4. It is concluded that the receptor and neural mechanisms that mediate visual-acuity function similarly in rhesus and man, and that the differences in acuity that were measured in the two species may be attributed to optical rather than to physiological factors. PMID:4199366

  3. Search for high energy cosmic neutrino point sources with ANTARES

    International Nuclear Information System (INIS)

    Halladjian, G.

    2010-01-01

    The aim of this thesis is the search for high energy cosmic neutrinos emitted by point sources with the ANTARES neutrino telescope. The detection of high energy cosmic neutrinos can bring answers to important questions such as the origin of cosmic rays and the γ-rays emission processes. In the first part of the thesis, the neutrino flux emitted by galactic and extragalactic sources and the number of events which can be detected by ANTARES are estimated. This study uses the measured γ-ray spectra of known sources taking into account the γ-ray absorption by the extragalactic background light. In the second part of the thesis, the absolute pointing of the ANTARES telescope is evaluated. Being located at a depth of 2475 m in sea water, the orientation of the detector is determined by an acoustic positioning system which relies on low and high frequency acoustic waves measurements between the sea surface and the bottom. The third part of the thesis is a search for neutrino point sources in the ANTARES data. The search algorithm is based on a likelihood ratio maximization method. It is used in two search strategies; 'the candidate sources list strategy' and 'the all sky search strategy'. Analysing 2007+2008 data, no discovery is made and the world's best upper limits on neutrino fluxes from various sources in the Southern sky are established. (author)

  4. Advances and synergy of high pressure sciences at synchrotron sources

    International Nuclear Information System (INIS)

    Liu, H.; Ehm, L.; Duffy, T.; Crichton, W.; Aoki, K.

    2009-01-01

    Introductory overview to the special issue papers on high-pressure sciences and synchrotron radiation. High-pressure research in geosciences, materials science and condensed matter physics at synchrotron sources is experiencing growth and development through synergistic efforts around the world. A series of high-pressure science workshops were organized in 2008 to highlight these developments. One of these workshops, on 'Advances in high-pressure science using synchrotron X-rays', was held at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, USA, on 4 October 2008. This workshop was organized in honour of Drs Jingzhu Hu and Quanzhong Guo in celebration of their retirement after up to 18 years of dedicated service to the high-pressure community as beamline scientists at X17 of NSLS. Following this celebration of the often unheralded role of the beamline scientist, a special issue of the Journal of Synchrotron Radiation on Advances and Synergy of High-Pressure Sciences at Synchrotron Sources was proposed, and we were pleased to invite contributions from colleagues who participated in the workshop as well as others who are making similar efforts at synchrotron sources worldwide.

  5. The impact of luminance on tonic and phasic pupillary responses to sustained cognitive load.

    Science.gov (United States)

    Peysakhovich, Vsevolod; Vachon, François; Dehais, Frédéric

    2017-02-01

    Pupillary reactions independent of light conditions have been linked to cognition for a long time. However, the light conditions can impact the cognitive pupillary reaction. Previous studies underlined the impact of luminance on pupillary reaction, but it is still unclear how luminance modulates the sustained and transient components of pupillary reaction - tonic pupil diameter and phasic pupil response. In the present study, we investigated the impact of the luminance on these two components under sustained cognitive load. Fourteen participants performed a novel working memory task combining mathematical computations with a classic n-back task. We studied both tonic pupil diameter and phasic pupil response under low (1-back) and high (2-back) working memory load and two luminance levels (gray and white). We found that the impact of working memory load on the tonic pupil diameter was modulated by the level of luminance, the increase in tonic pupil diameter with the load being larger under lower luminance. In contrast, the smaller phasic pupil response found under high load remained unaffected by luminance. These results showed that luminance impacts the cognitive pupillary reaction - tonic pupil diameter (phasic pupil response) being modulated under sustained (respectively, transient) cognitive load. These findings also support the relationship between the locus-coeruleus system, presumably functioning in two firing modes - tonic and phasic - and the pupil diameter. We suggest that the tonic pupil diameter tracks the tonic activity of the locus-coeruleus while phasic pupil response reflects its phasic activity. Besides, the designed novel cognitive paradigm allows the simultaneous manipulation of sustained and transient components of the cognitive load and is useful for dissociating the effects on the tonic pupil diameter and phasic pupil response. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. A pocket-sized luminance meter.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1964-01-01

    In many case the light technician will feel the want of assessing the luminance of certain surfaces within his field of view in a quick and convenient manner. The measurement need not be very accurate, but it should be carried out with an apparatus so small that it can easily be taken along

  7. Optical system for a universal luminance meter

    NARCIS (Netherlands)

    Schreuder, D.A.

    1965-01-01

    There is a need for luminance meters in various fields of photometry having these characteristics: a- objective method of measurements. b. variable shape and size of measurement area. c- absence of parallax during aiming operations. d- Possibility of observing the part of the field of view to be

  8. The Exponent of High-frequency Source Spectral Falloff and Contribution to Source Parameter Estimates

    Science.gov (United States)

    Kiuchi, R.; Mori, J. J.

    2015-12-01

    As a way to understand the characteristics of the earthquake source, studies of source parameters (such as radiated energy and stress drop) and their scaling are important. In order to estimate source parameters reliably, often we must use appropriate source spectrum models and the omega-square model is most frequently used. In this model, the spectrum is flat in lower frequencies and the falloff is proportional to the angular frequency squared. However, Some studies (e.g. Allmann and Shearer, 2009; Yagi et al., 2012) reported that the exponent of the high frequency falloff is other than -2. Therefore, in this study we estimate the source parameters using a spectral model for which the falloff exponent is not fixed. We analyze the mainshock and larger aftershocks of the 2008 Iwate-Miyagi Nairiku earthquake. Firstly, we calculate the P wave and SH wave spectra using empirical Green functions (EGF) to remove the path effect (such as attenuation) and site effect. For the EGF event, we select a smaller earthquake that is highly-correlated with the target event. In order to obtain the stable results, we calculate the spectral ratios using a multitaper spectrum analysis (Prieto et al., 2009). Then we take a geometric mean from multiple stations. Finally, using the obtained spectra ratios, we perform a grid search to determine the high frequency falloffs, as well as corner frequency of both of events. Our results indicate the high frequency falloff exponent is often less than 2.0. We do not observe any regional, focal mechanism, or depth dependencies for the falloff exponent. In addition, our estimated corner frequencies and falloff exponents are consistent between the P wave and SH wave analysis. In our presentation, we show differences in estimated source parameters using a fixed omega-square model and a model allowing variable high-frequency falloff.

  9. Sources

    International Nuclear Information System (INIS)

    Duffy, L.P.

    1991-01-01

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  10. Operation of the ORNL High Particle Flux Helicon Plasma Source

    International Nuclear Information System (INIS)

    Goulding, Richard Howell; Biewer, Theodore M.; Caughman, John B.; Chen, Guangye; Owen, Larry W.; Sparks, Dennis O.

    2011-01-01

    A high power, high particle flux rf-based helicon plasma source has been constructed at ORNL and operated at power levels up to 30 kW. High-density hydrogen and helium plasmas have been produced. The source has been designed as the basis for a linear plasma materials interaction (PMI) test facility that will generate particle fluxes Gamma(p) > 10(23) M-3 s(-1), and utilize additional ion and electron cyclotron heating to produce high parallel (to the magnetic field) heat fluxes of similar to 10 MW/m(2). An rf-based source for PMI research is of interest because high plasma densities are generated with no internal electrodes, allowing true steady state operation with minimal impurity generation. The ORNL helicon source has a diameter of 15 cm and to-date has operated at a frequency f = 13.56 MHz, with magnetic field strength vertical bar B vertical bar in the antenna region up to similar to 0.15 T. Maximum densities of 3 x 10(19) M-3 in He and 2.5 x 10(19) m(-3) in H have been achieved. Radial density profiles have been seen to be dependent on the axial vertical bar B vertical bar profile.

  11. Operation of the ORNL High Particle Flux Helicon Plasma Source

    International Nuclear Information System (INIS)

    Goulding, R. H.; Biewer, T. M.; Caughman, J. B. O.; Chen, G. C.; Owen, L. W.; Sparks, D. O.

    2011-01-01

    A high power, high particle flux rf-based helicon plasma source has been constructed at ORNL and operated at power levels up to 30 kW. High-density hydrogen and helium plasmas have been produced. The source has been designed as the basis for a linear plasma materials interaction (PMI) test facility that will generate particle fluxes Γ p 10 23 m -3 s -1 , and utilize additional ion and electron cyclotron heating to produce high parallel (to the magnetic field) heat fluxes of ∼10 MW/m 2 . An rf-based source for PMI research is of interest because high plasma densities are generated with no internal electrodes, allowing true steady state operation with minimal impurity generation. The ORNL helicon source has a diameter of 15 cm and to-date has operated at a frequency f = 13.56 MHz, with magnetic field strength |B| in the antenna region up to ∼0.15 T. Maximum densities of 3x10 19 m -3 in He and 2.5x10 19 m -3 in H have been achieved. Radial density profiles have been seen to be dependent on the axial |B| profile.

  12. Very high flux steady state reactor and accelerator based sources

    International Nuclear Information System (INIS)

    Ludewig, H.; Todosow, M.; Simos, N.; Shapiro, S.; Hastings, J.

    2004-01-01

    With the number of steady state neutron sources in the US declining (including the demise of the Bnl HFBR) the remaining intense sources are now in Europe (i.e. reactors - ILL and FMR, accelerator - PSI). The intensity of the undisturbed thermal flux for sources currently in operation ranges from 10 14 n/cm 2 *s to 10 15 n/cm 2 *s. The proposed Advanced Neutron Source (ANS) was to be a high power reactor (about 350 MW) with a projected undisturbed thermal flux of 7*10 15 n/cm 2 *s but never materialized. The objective of the current study is to explore the requirements and implications of two source concepts with an undisturbed flux of 10 16 n/cm 2 *s. The first is a reactor based concept operating at high power density (10 MW/l - 15 MW/l) and a total power of 100 MW - 250 MW, depending on fissile enrichment. The second is an accelerator based concept relying on a 1 GeV - 1.5 GeV proton Linac with a total beam power of 40 MW and a liquid lead-bismuth eutectic target. In the reactor source study, the effects of fissile material enrichment, coolant temperature and pressure drop, and estimates of pressure vessel stress levels will be investigated. The fuel form for the reactor will be different from all other operating source reactors in that it is proposed to use an infiltrated graphitic structure, which has been developed for nuclear thermal propulsion reactor applications. In the accelerator based source the generation of spallation products and their activation levels, and the material damage sustained by the beam window will be investigated. (authors)

  13. Environments of High Luminosity X-Ray Sources in the Antennae Galaxies

    Science.gov (United States)

    Clark, D. M.; Eikenberry, S. S.; Brandl, B. R.; Wilson, J. C.; Carson, J. C.; Henderson, C. P.; Hayward, T. P.; Barry, D. J.; Houck, J. R.; Ptak, A.; Colbert, E.

    2003-12-01

    We use deep J (1.25 μ m) and Ks (2.15 μ m) images of the Antennae (NGC 4038/9) obtained with the Wide-field InfraRed Camera on the Palomar 200-inch telescope, together with the Chandra X-ray source list of Zezas et al. (2001), to establish an X-ray/IR astrometric frame tie with ˜ 0.5 ″ RMS residuals over a ˜ 5 ‧ field. We find 13 ``strong" IR counterparts 99.9% confidence), and that the X-ray/IR matches are concentrated in the spiral arms and ``bridge" regions of the Antennae. This implies that these X-ray sources lie in the most ``super" of the Antennae's Super Star Clusters, and thus trace the recent massive star formation history here. Based on the NH inferred from the X-ray sources without IR counterparts, we determine that the absence of most of the ``missing" IR counterparts is not due to extinction, but that these sources are intrinsically less luminous in the IR, implying that they trace a different (older?) stellar population. We find no clear correlation between X-ray luminosity classes and IR properties of the sources, though small number statistics hamper this analysis. Finally, we find a Ks = 16.2 mag counterpart to the Ultra-Luminous X-ray (ULX) source X-37 within <0.5 ″ , eliminating the need for the ``runaway binary" hypothesis proposed by previous authors for this object. We discuss some of the implications of this detection for models of ULX emission. This work is funded by an NSF CAREER grant.

  14. Ecology and biology of luminous bacteria in the Arabian Sea

    Digital Repository Service at National Institute of Oceanography (India)

    Ramaiah, N.; Chandramohan, D.

    Extensive studies on occurrence, distribution and species composition of luminous bacteria in the Arabian Sea were carried out from various habitats. Luminous bacterial population was by far the highest in the environs of the Arabian Sea...

  15. Intense neutron source: high-voltage power supply specifications

    International Nuclear Information System (INIS)

    Riedel, A.A.

    1980-08-01

    This report explains the need for and sets forth the electrical, mechanical and safety specifications for a high-voltage power supply to be used with the intense neutron source. It contains sufficient information for a supplier to bid on such a power supply

  16. Analyses of High-Energy Sources with ESA Gaia

    Czech Academy of Sciences Publication Activity Database

    Hudec, R.; Šimon, Vojtěch; Hudcová, Věra

    2010-01-01

    Roč. 1248, - (2010), s. 583-584 ISSN 1551-7616. [X-ray astronomy 2009. Bologna, 07.09.2009-11.09.2009] Institutional research plan: CEZ:AV0Z10030501 Keywords : high-energy sources * gamma-ray bursts * low-dispersion spectra Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  17. High School Principals as Leaders: Styles and Sources of Power

    Science.gov (United States)

    Brinia, Vasiliki; Papantoniou, Eva

    2016-01-01

    Purpose: The purpose of this paper is to present the characteristics of leadership (style adopted, sources of power exercised and factors affecting leadership) of high school principals in Greece. Design/Methodology/Approach: In total, 235 school principals were surveyed using questionnaires. These questionnaires assessed how often they adopted…

  18. degradable protein sources on performance of high-producing dairy ...

    African Journals Online (AJOL)

    with high-quality, low·degradable protein sources prOViding47% UDP is advocated for ... saliva and through the rumen wall (Waldo, 1968). Based on this type of ... of the feed industry, but is based on very little solid evidence. (Huber, 1984). Chalupa ...... of rumen fermentation in relation to ammonia concentration. Br. J. Nutr.

  19. Near-field visual acuity of pigeons: effects of head location and stimulus luminance.

    Science.gov (United States)

    Hodos, W; Leibowitz, R W; Bonbright, J C

    1976-03-01

    Two pigeons were trained to discriminate a grating stimulus from a blank stimulus of equivalent luminance in a three-key chamber. The stimuli and blanks were presented behind a transparent center key. The procedure was a conditional discrimination in which pecks on the left key were reinforced if the blank had been present behind the center key and pecks on the right key were reinforced if the grating had been present behind the center key. The spatial frequency of the stimuli was varied in each session from four to 29.5 lines per millimeter in accordance with a variation of the method of constant stimuli. The number of lines per millimeter that the subjects could discriminate at threshold was determined from psychometric functions. Data were collected at five values of stimulus luminance ranging from--0.07 to 3.29 log cd/m2. The distance from the stimulus to the anterior nodal point of the eye, which was determined from measurements taken from high-speed motion-picture photographs of three additional pigeons and published intraocular measurements, was 62.0 mm. This distance and the grating detection thresholds were used to calculate the visual acuity of the birds at each level of luminance. Acuity improved with increasing luminance to a peak value of 0.52, which corresponds to a visual angle of 1.92 min, at a luminance of 2.33 log cd/m2. Further increase in luminance produced a small decline in acuity.

  20. Analyzing the Largest Spectroscopic Data Set of Hydrogen-poor Super-luminous Supernovae

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yu-Qian; Modjaz, Maryam; Bianco, Federica B., E-mail: YL1260@nyu.edu, E-mail: mmodjaz@nyu.edu [Center for Cosmology and Particle Physics, New York University, 4 Washington Place, New York, NY 10003 (United States)

    2017-08-10

    Super-luminous supernovae (SLSNe) are tremendously luminous explosions whose power sources and progenitors are highly debated. Broad-lined SNe Ic (SNe Ic-bl) are the only type of SNe that are connected with long-duration gamma-ray bursts (GRBs). Studying the spectral similarity and difference between the populations of hydrogen-poor SLSNe (SLSNe Ic) and of hydrogen-poor stripped-envelope core-collapse SNe, in particular SNe Ic and SNe Ic-bl, can provide crucial observations to test predictions of theories based on various power source models and progenitor models. In this paper, we collected all of the published optical spectra of 32 SLSNe Ic, 21 SNe Ic-bl, as well as 17 SNe Ic, quantified their spectral features, constructed average spectra, and compared them in a systematic way using new tools we have developed. We find that SLSNe Ic and SNe Ic-bl, including those connected with GRBs, have comparable widths for their spectral features and average absorption velocities at all phases. Thus, our findings strengthen the connection between SLSNe Ic and GRBs. In particular, SLSNe Ic have average Fe ii λ 5169 absorption velocities of −15,000 ± 2600 km s{sup −1} at 10 days after peak, which are higher than those of SNe Ic by ∼7000 km s{sup −1} on average. SLSNe Ic also have significantly broader Fe ii λ 5169 lines than SNe Ic. Moreover, we find that such high absorption and width velocities of SLSNe Ic may be hard to explain with the interaction model, and none of the 13 SLSNe Ic with measured absorption velocities spanning over 10 days has a convincing flat velocity evolution, which is inconsistent with the magnetar model in one dimension. Lastly, we compare SN 2011kl, the first SN connected with an ultra-long GRB, with the mean spectrum of SLSNe Ic and of SNe Ic-bl.

  1. Management of spent high activity radioactive sources (SHARS)

    International Nuclear Information System (INIS)

    2002-09-01

    The objective of this report is to provide all people involved in the handling and management of high activity sources with sufficient information about processes that are required for the safe management of spent high activity radioactive sources (SHARS). This includes examples of spent source management that are already taking place and also a description of the range of appropriate options that are available for each stage in the management process. This report also aims to identify the important issues to be addressed in order to develop a waste management strategy as part of the integrated management strategy that takes account of international experience and the guidance and principles that have been learned from that experience. This report relates specifically to SHARS, which are spent sources that have the potential, with short exposures, to produce acute health effects if handled incorrectly. In addition, they may also incur significant economic costs in any retrieval or environmental remediation operation, following loss of or damage to such a source. The report provides guidance on the technical, administrative and economic issues associated with SHARS from the moment they cease to be in use through to disposal, including temporary storage, transport, conditioning and interim storage

  2. Production of highly charged ion beams from ECR ion sources

    International Nuclear Information System (INIS)

    Xie, Z.Q.

    1997-09-01

    Electron Cyclotron Resonance (ECR) ion source development has progressed with multiple-frequency plasma heating, higher mirror magnetic fields and better technique to provide extra cold electrons. Such techniques greatly enhance the production of highly charged ions from ECR ion sources. So far at cw mode operation, up to 300 eμA of O 7+ and 1.15 emA of O 6+ , more than 100 eμA of intermediate heavy ions for charge states up to Ar 13+ , Ca 13+ , Fe 13+ , Co 14+ and Kr 18+ , and tens of eμA of heavy ions with charge states to Kr 26+ , Xe 28+ , Au 35+ , Bi 34+ and U 34+ have been produced from ECR ion sources. At an intensity of at least 1 eμA, the maximum charge state available for the heavy ions are Xe 36+ , Au 46+ , Bi 47+ and U 48+ . An order of magnitude enhancement for fully stripped argon ions (I ≥ 60 enA) also has been achieved. This article will review the ECR ion source progress and discuss key requirement for ECR ion sources to produce the highly charged ion beams

  3. ELBE Center for High-Power Radiation Sources

    Directory of Open Access Journals (Sweden)

    Peter Dr. Michel

    2016-01-01

    Full Text Available In the ELBE Center for High-Power Radiation Sources, the superconducting linear electron accelerator ELBE, serving  two free electron lasers, sources for intense coherent THz radiation, mono-energetic positrons, electrons, γ-rays, a neutron time-of-flight system as well as two synchronized ultra-short pulsed Petawatt laser systems are collocated. The characteristics of these beams make the ELBE center a unique research instrument for a variety of external users in fields ranging from material science over nuclear physics to cancer research, as well as scientists of the Helmholtz-Zentrum Dresden-Rossendorf (HZDR.

  4. New sources of high-power coherent radiation

    International Nuclear Information System (INIS)

    Sprehngl, F.

    1985-01-01

    New sources of high-power coherent radiation in the wavelength range from millimeter to ultraviolet are reviewed. Physical mechanisms underlying concepts of free electrons laser, cyclotron resonance laser and other new radiation sources are described. Free electron lasers and cyclotron resonance lasers are shown to suggest excellent possibilities for solving problems of spectroscopy, plasma heating radar and accelerator technology. Results of experiments with free electron laser in the Compton mode using linear accelerators microtrons and storage rings are given. Trends in further investigations are shown

  5. CHESS-the Cornell High Energy Synchrotron Source

    International Nuclear Information System (INIS)

    Batterman, B.W.; Cornell Univ., Ithaca, NY

    1980-01-01

    The Wilson Laboratory at Cornell University has done pioneering work on development of high energy synchrotrons. In the last decade, the 12 GeV synchrotron has been the most energetic electron synchrotron in the world. In 1975 plans were formulated to build a 4-8 GeV storage ring in the same tunnel as the synchrotron and to use the latter as the injector for the storage ring. This small radius (the normal bend magnets have R = 87 m), coupled with the relatively high electron energy of the storage ring, makes these magnets potent sources of synchrotron radiation. In June of 1978 the National Science Foundation funded a project to create CHESS, the Cornell High Energy Synchrotron Source. (orig./FKS)

  6. Overcoming High Energy Backgrounds at Pulsed Spallation Sources

    CERN Document Server

    Cherkashyna, Nataliia; DiJulio, Douglas D.; Khaplanov, Anton; Pfeiffer, Dorothea; Scherzinger, Julius; Cooper-Jensen, Carsten P.; Fissum, Kevin G.; Ansell, Stuart; Iverson, Erik B.; Ehlers, Georg; Gallmeier, Franz X.; Panzner, Tobias; Rantsiou, Emmanouela; Kanaki, Kalliopi; Filges, Uwe; Kittelmann, Thomas; Extegarai, Maddi; Santoro, Valentina; Kirstein, Oliver; Bentley, Phillip M.

    2015-01-01

    Instrument backgrounds at neutron scattering facilities directly affect the quality and the efficiency of the scientific measurements that users perform. Part of the background at pulsed spallation neutron sources is caused by, and time-correlated with, the emission of high energy particles when the proton beam strikes the spallation target. This prompt pulse ultimately produces a signal, which can be highly problematic for a subset of instruments and measurements due to the time-correlated properties, and different to that from reactor sources. Measurements of this background have been made at both SNS (ORNL, Oak Ridge, TN, USA) and SINQ (PSI, Villigen, Switzerland). The background levels were generally found to be low compared to natural background. However, very low intensities of high-energy particles have been found to be detrimental to instrument performance in some conditions. Given that instrument performance is typically characterised by S/N, improvements in backgrounds can both improve instrument pe...

  7. Very high energy emission sources beyond the Galaxy

    Directory of Open Access Journals (Sweden)

    Sinitsyna V.G.

    2017-01-01

    Full Text Available Active Galactic Nuclei (AGN are considered as potential extragalactic sources of very and ultra high energy cosmic rays. According to theoretical predictions cosmic ray acceleration can take place at the shock created by the expanding cocoons around active galactic nuclei as well as at AGN jets. The measurements of AGN TeV spectra, the variability time scale of TeV emission can provide essential information on the dynamics of AGN jets, the localization of acceleration region and an estimation of its size. SHALON observations yielded data on extragalactic sources of different AGN types in the energy range of 800 GeV–100 TeV. The data from SHALON observations are compared with those from other experiments at high and very high energies.

  8. Active Galactic Nuclei: Sources for ultra high energy cosmic rays?

    International Nuclear Information System (INIS)

    Biermann, Peter L.; Becker, Julia K.; Caramete, Laurentiu; Curutiu, Alex; Engel, Ralph; Falcke, Heino; Gergely, Laszlo A.; Isar, P. Gina; Maris, Ioana C.; Meli, Athina; Kampert, Karl-Heinz; Stanev, Todor; Tascau, Oana; Zier, Christian

    2009-01-01

    The origin of ultra high energy cosmic rays promises to lead us to a deeper understanding of the structure of matter. This is possible through the study of particle collisions at center-of-mass energies in interactions far larger than anything possible with the Large Hadron Collider, albeit at the substantial cost of no control over the sources and interaction sites. For the extreme energies we have to identify and understand the sources first, before trying to use them as physics laboratories. Here we describe the current stage of this exploration. The most promising contenders as sources are radio galaxies and gamma ray bursts. The sky distribution of observed events yields a hint favoring radio galaxies. Key in this quest are the intergalactic and galactic magnetic fields, whose strength and structure are not yet fully understood. Current data and statistics do not yet allow a final judgement. We outline how we may progress in the near future.

  9. Active Galactic Nuclei: Sources for ultra high energy cosmic rays?

    Energy Technology Data Exchange (ETDEWEB)

    Biermann, Peter L. [MPI for Radioastronomy, Bonn (Germany); Dept. of Phys. and Astron., Univ. of Bonn (Germany); Dept. of Phys. and Astr., Univ. of Alabama, Tuscaloosa, AL (United States); Dept. of Phys., Univ. of Alabama at Huntsville, AL (United States); Inst. Nucl. Phys. FZ, Karlsruhe Inst. of Techn. (KIT) (Germany); Becker, Julia K. [Institution foer Fysik, Goeteborgs Univ. (Sweden); Dept. of Phys., Univ. Dortmund, Dortmund (Germany); Caramete, Laurentiu [MPI for Radioastronomy, Bonn (Germany); Institute for Space Studies, Bucharest (Romania); Curutiu, Alex [MPI for Radioastronomy, Bonn (Germany); Engel, Ralph [Inst. Nucl. Phys. FZ, Karlsruhe Inst. of Techn. (KIT) (Germany); Falcke, Heino [Dept. of Astrophys., IMAP, Radboud Univ., Nijmegen (Netherlands); ASTRON, Dwingeloo (Netherlands); Gergely, Laszlo A. [Dept. Appl. Sci., London South Bank University (United Kingdom); Dept. of Theoret. and Exp. Phys., Univ. of Szeged, Szeged (Hungary); Isar, P. Gina [Inst. Nucl. Phys. FZ, Karlsruhe Inst. of Techn. (KIT) (Germany); Institute for Space Studies, Bucharest (Romania); Maris, Ioana C. [Inst. Nucl. Phys. FZ, Karlsruhe Inst. of Techn. (KIT) (Germany); Meli, Athina [Physik. Inst. Univ. Erlangen-Nuernberg (Germany); Kampert, Karl-Heinz [Phys. Dept., Univ. Wuppertal (Germany); Stanev, Todor [Bartol Research Inst., Univ. of Delaware, Newark, DE (United States); Tascau, Oana [Phys. Dept., Univ. Wuppertal (Germany); Zier, Christian [MPI for Radioastronomy, Bonn (Germany); Raman Res. Inst., Bangalore (India)

    2009-05-15

    The origin of ultra high energy cosmic rays promises to lead us to a deeper understanding of the structure of matter. This is possible through the study of particle collisions at center-of-mass energies in interactions far larger than anything possible with the Large Hadron Collider, albeit at the substantial cost of no control over the sources and interaction sites. For the extreme energies we have to identify and understand the sources first, before trying to use them as physics laboratories. Here we describe the current stage of this exploration. The most promising contenders as sources are radio galaxies and gamma ray bursts. The sky distribution of observed events yields a hint favoring radio galaxies. Key in this quest are the intergalactic and galactic magnetic fields, whose strength and structure are not yet fully understood. Current data and statistics do not yet allow a final judgement. We outline how we may progress in the near future.

  10. High Flux Isotope Reactor cold neutron source reference design concept

    International Nuclear Information System (INIS)

    Selby, D.L.; Lucas, A.T.; Hyman, C.R.

    1998-05-01

    In February 1995, Oak Ridge National Laboratory's (ORNL's) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH 2 ) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH 2 cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept

  11. High Flux Isotope Reactor cold neutron source reference design concept

    Energy Technology Data Exchange (ETDEWEB)

    Selby, D.L.; Lucas, A.T.; Hyman, C.R. [and others

    1998-05-01

    In February 1995, Oak Ridge National Laboratory`s (ORNL`s) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH{sub 2}) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH{sub 2} cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept.

  12. White LEDs with limit luminous efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Lisitsyn, V. M.; Stepanov, S. A., E-mail: stepanovsa@tpu.ru; Yangyang, Ju [National Research Tomsk Polytechnic University, 30 Lenin Av., Tomsk, 634050 (Russian Federation); Lukash, V. S. [JSC Research Institute of Semiconductor Devices, 99a Krasnoarmeyskaja St., Tomsk, 634050 (Russian Federation)

    2016-01-15

    In most promising widespread gallium nitride based LEDs emission is generated in the blue spectral region with a maximum at about 450 nm which is converted to visible light with the desired spectrum by means of phosphor. The thermal energy in the conversion is determined by the difference in the energies of excitation and emission quanta and the phosphor quantum yield. Heat losses manifest themselves as decrease in the luminous efficacy. LED heating significantly reduces its efficiency and life. In addition, while heating, the emission generation output and the efficiency of the emission conversion decrease. Therefore, the reduction of the energy losses caused by heating is crucial for LED development. In this paper, heat losses in phosphor-converted LEDs (hereinafter chips) during spectrum conversion are estimated. The limit values of the luminous efficacy for white LEDs are evaluated.

  13. The new high flux neutron source FRM-2 in Munich

    International Nuclear Information System (INIS)

    Roegler, H.J.; Wierheim, G.

    2002-01-01

    Quite some years ago in 1974 to be exact, the first consideration on a new neutron source started at the technical university of Munich (Germany). 27 years later the new high flux neutron source (FRM-2) was read for hot operation, now delayed by a refused approval for its third partial license by the federal government of Germany despite a wide support from the scientific community. FRM-2 is a tank-type research reactor cooled by water, moderated by heavy water and whose thermal power was limited to 20 MW maximum. The extreme compact core together with the applied inverse flux principle led to a neutron flux design value of 8.10 18 n/m 2 .s at the reflector peak. 10 beam tubes will allow an optimized use of the high neutron flux. A hot neutron source with graphite at about 2200 Celsius degrees and a cold neutron source with liquid D 2 at about 25 K will provide shifted energy spectra. The utilization of FRM-2 is many-fold: neutronography and tomography, medical irradiation, radio-nuclide production, doping of pure silicon, neutron activation analysis. (A.C.)

  14. Characteristics of estrogen-induced peroxidase in mouse uterine luminal fluid

    International Nuclear Information System (INIS)

    Jellinck, P.H.; Newbold, R.R.; McLachlan, J.A.

    1991-01-01

    Peroxidase activity in the uterine luminal fluid of mice treated with diethylstilbestrol was measured by the guaiacol assay and also by the formation of 3H2O from [2-3H]estradiol. In the radiometric assay, the generation of 3H2O and 3H-labeled water-soluble products was dependent on H2O2 (25 to 100 microM), with higher concentrations being inhibitory. Tyrosine or 2,4-dichlorophenol strongly enhanced the reaction catalyzed either by the luminal fluid peroxidase or the enzyme in the CaCl2 extract of the uterus, but decreased the formation of 3H2O from [2-3H]estradiol by lactoperoxidase in the presence of H2O2 (80 microM). NADPH, ascorbate, and cytochrome c inhibited both luminal fluid and uterine tissue peroxidase activity to the same extent, while superoxide dismutase showed a marginal activating effect. Lactoferrin, a major protein component of uterine luminal fluid, was shown not to contribute to its peroxidative activity, and such an effect by prostaglandin synthase was also ruled out. However, it was not possible to exclude eosinophil peroxidase, brought to the uterus after estrogen stimulation, as being the source of peroxidase activity in uterine luminal fluid

  15. Large area negative ion source for high voltage neutral beams

    International Nuclear Information System (INIS)

    Poulsen, P.; Hooper, E.B. Jr.

    1979-11-01

    A source of negative deuterium ions in the multi-ampere range is described that is readily extrapolated to reactor size, 10 amp or more of neutral beam, that is of interest in future experiments and reactors. The negative ion source is based upon the double charge exchange process. A beam of positive ions is created and accelerated to an energy at which the attachment process D + M → D - + M + proceeds efficiently. The positive ions are atomically neutralized either in D 2 or in the charge exchange medium M. Atomic species make a second charge exchange collision in the charge target to form D - . For a sufficiently thick target, the beam reaches an equilibrium fraction of negative ions. For reasons of efficiency, the target is typically alkali metal vapor; this experiment uses sodium. The beam of negative ions can be accelerated to high (>200 keV) energy, the electrons stripped from the ions, and a high energy neutral beam formed

  16. PV source based high voltage gain current fed converter

    Science.gov (United States)

    Saha, Soumya; Poddar, Sahityika; Chimonyo, Kudzai B.; Arunkumar, G.; Elangovan, D.

    2017-11-01

    This work involves designing and simulation of a PV source based high voltage gain, current fed converter. It deals with an isolated DC-DC converter which utilizes boost converter topology. The proposed converter is capable of high voltage gain and above all have very high efficiency levels as proved by the simulation results. The project intends to produce an output of 800 V dc from a 48 V dc input. The simulation results obtained from PSIM application interface were used to analyze the performance of the proposed converter. Transformer used in the circuit steps up the voltage as well as to provide electrical isolation between the low voltage and high voltage side. Since the converter involves high switching frequency of 100 kHz, ultrafast recovery diodes are employed in the circuitry. The major application of the project is for future modeling of solar powered electric hybrid cars.

  17. Light and Light Sources High-Intensity Discharge Lamps

    CERN Document Server

    Flesch, Peter G

    2006-01-01

    Light and Light Sources gives an introduction to the working principles of high-intensity discharge (HID) lamps and points out challenges and problems associated with the development and operation of HID lamps. The state-of-the-art in electrode and plasma diagnostics as well as numerical methods used for the understanding of HID lamps are described. This volume addresses students as well as scientists and researchers at universities and in industry.

  18. Proton induction linacs as high-intensity neutron sources

    International Nuclear Information System (INIS)

    Keefe, D.; Hoyer, E.

    1981-01-01

    Proton induction linacs are explored as high intensity neutron sources. The induction linac - concept, properties, experience with electrons, and possibilities - and its limitations for accelerating ions are reviewed. A number of proton induction linac designs are examined with the LIACEP program and general conclusions are given. Results suggest that a proton induction accelerator of the lowest voltage, consistent with good neutron flux, is preferred and could well be cost competitive with the usual rf linac/storage ring designs. (orig.)

  19. Testing Special Relativity at High Energies with Astrophysical Sources

    Science.gov (United States)

    Stecker, F. W.

    2007-01-01

    Since the group of Lorentz boosts is unbounded, there is a question as to whether Lorentz invariance (LI) holds to infinitely short distances. However, special and general relativity may break down at the Planck scale. Various quantum gravity scenarios such as loop quantum gravity, as well as some forms of string theory and extra dimension models may imply Lorentz violation (LV) at ultrahigh energies. The Gamma-Ray Large Area Space Telescope (GLAST), to be launched in mid-December, will measure the spectra of distant extragalactic sources of high energy gamma-rays, particularly active galactic nuclei and gamma-ray bursts. GLAST can look for energy-dependent gamma-ray propagation effects from such sources as a signal of Lorentz invariance violation. These sources may also exhibit the high energy cutoffs predicted to be the result of intergalactic annihilation interactions with low energy photons having a flux level as determined by various astronomical observations. With LV the threshold for such interactions can be significantly raised, changing the predicted absorption turnover in the observed spectrum of the sources. Stecker and Glashow have shown that the existence such absorption features in the spectra of extragalactic sources puts constraints on LV. Such constraints have important implications for some quantum gravity and large extra dimension models. Future spaceborne detectors dedicated to measuring gamma-ray polarization can look for birefringence effects as a possible signal of loop quantum gravity. A very small LV may also result in the modification or elimination of the GZK effect, thus modifying the spectrum of ultrahigh energy cosmic rays. This possibility can be explored with ground-based arrays such as Auger or with a space based detector system such as the proposed OWL satellite mission.

  20. High average power, highly brilliant laser-produced plasma source for soft X-ray spectroscopy.

    Science.gov (United States)

    Mantouvalou, Ioanna; Witte, Katharina; Grötzsch, Daniel; Neitzel, Michael; Günther, Sabrina; Baumann, Jonas; Jung, Robert; Stiel, Holger; Kanngiesser, Birgit; Sandner, Wolfgang

    2015-03-01

    In this work, a novel laser-produced plasma source is presented which delivers pulsed broadband soft X-radiation in the range between 100 and 1200 eV. The source was designed in view of long operating hours, high stability, and cost effectiveness. It relies on a rotating and translating metal target and achieves high stability through an on-line monitoring device using a four quadrant extreme ultraviolet diode in a pinhole camera arrangement. The source can be operated with three different laser pulse durations and various target materials and is equipped with two beamlines for simultaneous experiments. Characterization measurements are presented with special emphasis on the source position and emission stability of the source. As a first application, a near edge X-ray absorption fine structure measurement on a thin polyimide foil shows the potential of the source for soft X-ray spectroscopy.

  1. Highly Stripped Ion Sources for MeV Ion Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, Ady

    2009-06-30

    Original technical objectives of CRADA number PVI C-03-09 between BNL and Poole Ventura, Inc. (PVI) were to develop an intense, high charge state, ion source for MeV ion implanters. Present day high-energy ion implanters utilize low charge state (usually single charge) ion sources in combination with rf accelerators. Usually, a MV LINAC is used for acceleration of a few rnA. It is desirable to have instead an intense, high charge state ion source on a relatively low energy platform (de acceleration) to generate high-energy ion beams for implantation. This de acceleration of ions will be far more efficient (in energy utilization). The resultant implanter will be smaller in size. It will generate higher quality ion beams (with lower emittance) for fabrication of superior semiconductor products. In addition to energy and cost savings, the implanter will operate at a lower level of health risks associated with ion implantation. An additional aim of the project was to producing a product that can lead to long­ term job creation in Russia and/or in the US. R&D was conducted in two Russian Centers (one in Tomsk and Seversk, the other in Moscow) under the guidance ofPVI personnel and the BNL PI. Multiple approaches were pursued, developed, and tested at various locations with the best candidate for commercialization delivered and tested at on an implanter at the PVI client Axcelis. Technical developments were exciting: record output currents of high charge state phosphorus and antimony were achieved; a Calutron-Bemas ion source with a 70% output of boron ion current (compared to 25% in present state-of-the-art). Record steady state output currents of higher charge state phosphorous and antimony and P ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb {sup 4 +}, Sb{sup 5+}, and Sb{sup 6+} respectively. Ultimate commercialization goals did not succeed (even though a number of the products like high

  2. Development of high current low energy H+ ion source

    International Nuclear Information System (INIS)

    Forrester, A.T.; Crow, J.T.; Goebel, D.M.

    1978-01-01

    The ultimate goal of this work is the development of an ion source suitable for double charge exchange of D + ions to D - ions in cesium or other vapor. Since the fraction of the D + which changes to D - may be as high as 0.35 in the energy below one keV, the process appears very favorable. What is desired is a source of several hundred cm 2 area, with a D + current density greater than, say 0.2A/cm 2 . Small angular spread is essential with up to about 0.1 radian being acceptable. A simple approach to this problem appears to be through fine mesh extraction electrodes. In this system a single grid facing the ion source plasma constitutes the entire extraction electrode system. If the potential difference between the grid and the source plasma is large compared to the ion energy at the plasma boundary, then the distance s 0 is just the Child-Langmuir distance corresponding to the ion current density J and the potential difference V 0 between the plasma and the grid

  3. High-intensity laser synchrotron x-ray source

    International Nuclear Information System (INIS)

    Pogorelsky, I.V.

    1995-10-01

    A laser interacting with a relativistic electron beam behaves like a virtual wiggler of an extremely short period equal to half of the laser wavelength. This approach opens a route to relatively compact, high-brightness x-ray sources alternative or complementary to conventional synchrotron light sources. Although not new, the Laser Synchrotron Light Source (LSLS) concept is still waiting for a convincing demonstration. Available at the BNL's Accelerator Test Facility (ATF), a high-brightness electron beam and the high-power C0 2 laser may be used as prototype LSLS brick stones. In a feasible demonstration experiment, 10-GW, 100-ps C0 2 laser beam will be brought to a head-on collision with a 10-ps, 0.5-nC, 70 MeV electron bunch. Flashes of well-collimated, up to 9.36-keV (∼ Angstrom) x-rays of 10-ps pulse duration, with a flux of ∼10 19 photons/sec will be produced via linear Compton backscattering. The x-ray spectrum is tunable proportionally to a variable e-beam energy. A natural short-term extension of the proposed experiment would be further enhancement of the x-ray flux to a 10 21 -10 22 photons/sec level, after the ongoing ATF CO 2 laser upgrade to 1 TW peak power and electron bunch shortening to 3 ps. The ATF LSLS x-ray beamline, exceeding by orders of magnitude the peak fluxes attained at the National Synchrotron Light Source (NSLS) x-ray storage ring, may become attractive for certain users, e.g., for biological x-ray microscopy. In addition, a terawatt CO 2 laser will enable harmonic multiplication of the x-ray spectrum via nonlinear Compton scattering

  4. A novel power source for high-precision, highly efficient micro w-EDM

    International Nuclear Information System (INIS)

    Chen, Shun-Tong; Chen, Chi-Hung

    2015-01-01

    The study presents the development of a novel power source for high-precision, highly efficient machining of micropart microstructures using micro wire electrical discharge machining (w-EDM). A novel power source based on a pluri resistance–capacitance (pRC) circuit that can generate a high-frequency, high-peak current with a short pulse train is proposed and designed to enhance the performance of micro w-EDM processes. Switching between transistors is precisely controlled in the designed power source to create a high-frequency short-pulse train current. Various microslot cutting tests in both aluminum and copper alloys are conducted. Experimental results demonstrate that the pRC power source creates instant spark erosion resulting in markedly less material for removal, diminishing discharge crater size, and consequently an improved surface finish. A new evaluation approach for spark erosion ability (SEA) to assess the merits of micro EDM power sources is also proposed. In addition to increasing the speed of micro w-EDM by increasing wire feed rates by 1.6 times the original feed rate, the power source is more appropriate for machining micropart microstructures since there is less thermal breaking. Satisfactory cutting of an elaborate miniature hook-shaped structure and a high-aspect ratio microstructure with a squared-pillar array also reveal that the developed pRC power source is effective, and should be very useful in the manufacture of intricate microparts. (paper)

  5. Conceptual design of a high-intensity positron source for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Hulett, L.D.; Eberle, C.C.

    1994-12-01

    The Advanced Neutron Source (ANS) is a planned new basic and applied research facility based on a powerful steady-state research reactor that provides neutrons for measurements and experiments in the fields of materials science and engineering, biology, chemistry, materials analysis, and nuclear science. The useful neutron flux will be at least five times more than is available in the world's best existing reactor facility. Construction of the ANS provides a unique opportunity to build a positron spectroscopy facility (PSF) with very-high-intensity beams based on the radioactive decay of a positron-generating isotope. The estimated maximum beam current is 1000 to 5000 times higher than that available at the world's best existing positron research facility. Such an improvement in beam capability, coupled with complementary detectors, will reduce experiment durations from months to less than one hour while simultaneously improving output resolution. This facility will remove the existing barriers to the routine use of positron-based analytical techniques and will be a giant step toward realization of the full potential of the application of positron spectroscopy to materials science. The ANS PSF is based on a batch cycle process using 64 Cu isotope as the positron emitter and represents the status of the design at the end of last year. Recent work not included in this report, has led to a proposal for placing the laboratory space for the positron experiments outside the ANS containment; however, the design of the positron source is not changed by that relocation. Hydraulic and pneumatic flight tubes transport the source material between the reactor and the positron source where the beam is generated and conditioned. The beam is then transported through a beam pipe to one of several available detectors. The design presented here includes all systems necessary to support the positron source, but the beam pipe and detectors have not been addressed yet

  6. A Compact, High-Flux Cold Atom Beam Source

    Science.gov (United States)

    Kellogg, James R.; Kohel, James M.; Thompson, Robert J.; Aveline, David C.; Yu, Nan; Schlippert, Dennis

    2012-01-01

    The performance of cold atom experiments relying on three-dimensional magneto-optical trap techniques can be greatly enhanced by employing a highflux cold atom beam to obtain high atom loading rates while maintaining low background pressures in the UHV MOT (ultra-high vacuum magneto-optical trap) regions. Several techniques exist for generating slow beams of cold atoms. However, one of the technically simplest approaches is a two-dimensional (2D) MOT. Such an atom source typically employs at least two orthogonal trapping beams, plus an additional longitudinal "push" beam to yield maximum atomic flux. A 2D atom source was created with angled trapping collimators that not only traps atoms in two orthogonal directions, but also provides a longitudinal pushing component that eliminates the need for an additional push beam. This development reduces the overall package size, which in turn, makes the 2D trap simpler, and requires less total optical power. The atom source is more compact than a previously published effort, and has greater than an order of magnitude improved loading performance.

  7. Environmental friendly high efficient light source plasma lamp - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Courret, G.; Calame, L. [Haute Ecole d' ingenierie et de gestion du canton de Vaud, Institut de micro et nano techniques, Yverdon-les-Bains (Switzerland); Meyer, A. [Solaronix SA, Aubonne (Switzerland)

    2007-07-01

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) takes a look at work done on the development of a sulphur-based plasma lamp. In 2007, the capability of a new modulator has been explored. The most important results are discussed. With the production of a 1.2 cm{sup 3} bulb, the way towards the production of a 100 W lamp has been opened. The authors comment that modulation by impulses increases the luminous efficiency in comparison to modulation using a continuous sinusoidal wave. The report deals with the history of the project, the development of the new modulator, the use of rotational effects and the optimisation of the amount of active substances - tellurium and selenium - in the bulb. The electromagnetic coupling system used is described and discussed.

  8. High flux isotope reactor cold source preconceptual design study report

    International Nuclear Information System (INIS)

    Selby, D.L.; Bucholz, J.A.; Burnette, S.E.

    1995-12-01

    In February 1995, the deputy director of Oak Ridge National Laboratory (ORNL) formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced Neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. The anticipated cold source will consist of a cryogenic LH 2 moderator plug, a cryogenic pump system, a refrigerator that uses helium gas as a refrigerant, a heat exchanger to interface the refrigerant with the hydrogen loop, liquid hydrogen transfer lines, a gas handling system that includes vacuum lines, and an instrumentation and control system to provide constant system status monitoring and to maintain system stability. The scope of this project includes the development, design, safety analysis, procurement/fabrication, testing, and installation of all of the components necessary to produce a working cold source within an existing HFIR beam tube. This project will also include those activities necessary to transport the cold neutron beam to the front face of the present HFIR beam room. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and research and development (R and D), (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the preconceptual phase and establishes the concept feasibility. The information presented includes the project scope, the preliminary design requirements, the preliminary cost and schedule, the preliminary performance data, and an outline of the various plans for completing the project

  9. DACH1: its role as a classifier of long term good prognosis in luminal breast cancer.

    Directory of Open Access Journals (Sweden)

    Desmond G Powe

    Full Text Available BACKGROUND: Oestrogen receptor (ER positive (luminal tumours account for the largest proportion of females with breast cancer. Theirs is a heterogeneous disease presenting clinical challenges in managing their treatment. Three main biological luminal groups have been identified but clinically these can be distilled into two prognostic groups in which Luminal A are accorded good prognosis and Luminal B correlate with poor prognosis. Further biomarkers are needed to attain classification consensus. Machine learning approaches like Artificial Neural Networks (ANNs have been used for classification and identification of biomarkers in breast cancer using high throughput data. In this study, we have used an artificial neural network (ANN approach to identify DACH1 as a candidate luminal marker and its role in predicting clinical outcome in breast cancer is assessed. MATERIALS AND METHODS: A reiterative ANN approach incorporating a network inferencing algorithm was used to identify ER-associated biomarkers in a publically available cDNA microarray dataset. DACH1 was identified in having a strong influence on ER associated markers and a positive association with ER. Its clinical relevance in predicting breast cancer specific survival was investigated by statistically assessing protein expression levels after immunohistochemistry in a series of unselected breast cancers, formatted as a tissue microarray. RESULTS: Strong nuclear DACH1 staining is more prevalent in tubular and lobular breast cancer. Its expression correlated with ER-alpha positive tumours expressing PgR, epithelial cytokeratins (CK18/19 and 'luminal-like' markers of good prognosis including FOXA1 and RERG (p<0.05. DACH1 is increased in patients showing longer cancer specific survival and disease free interval and reduced metastasis formation (p<0.001. Nuclear DACH1 showed a negative association with markers of aggressive growth and poor prognosis. CONCLUSION: Nuclear DACH1 expression

  10. Preparation of very small point sources for high resolution radiography

    International Nuclear Information System (INIS)

    Case, F.N.

    1976-01-01

    The need for very small point sources of high specific activity 192 Ir, 169 Yb, 170 Tm, and 60 Co in non-destructive testing has motivated the development of techniques for the fabrication of these sources. To prepare 192 Ir point sources for use in examination of tube sheet welds in LMFBR heat exchangers, 191 Ir enriched to greater than 90 percent was melted in a helium blanketed arc to form spheres as small as 0.38 mm in diameter. Methods were developed to form the roughly spherical shaped arc product into nearly symmetrical spheres that could be used for high resolution radiography. Similar methods were used for spherical shaped sources of 169 Yb and 170 Tm. The oxides were arc melted to form rough spheres followed by grinding to precise dimensions, neutron irradiation of the spheres at a flux of 2 to 3 x 10 15 nv, and use of enriched 168 Yb to provide the maximum specific activity. Cobalt-60 with a specific activity of greater than 1100 Ci/g was prepared by processing 59 Co that had been neutron irradiated to nearly complete burnup of the 59 Co target to produce 60 Co, 61 Ni, and 62 Ni. Ion exchange methods were used to separate the cobalt from the nickel. The cobalt was reduced to metal by plating either onto aluminum foil which was dissolved away from the cobalt plate, or by plating onto mercury to prepare amalgam that could be easily formed into a pellet of cobalt with exclusion of the mercury. Both methods are discussed

  11. Solion ion source for high-efficiency, high-throughput solar cell manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Koo, John, E-mail: john-koo@amat.com; Binns, Brant; Miller, Timothy; Krause, Stephen; Skinner, Wesley; Mullin, James [Applied Materials, Inc., Varian Semiconductor Equipment Business Unit, 35 Dory Road, Gloucester, Massachusetts 01930 (United States)

    2014-02-15

    In this paper, we introduce the Solion ion source for high-throughput solar cell doping. As the source power is increased to enable higher throughput, negative effects degrade the lifetime of the plasma chamber and the extraction electrodes. In order to improve efficiency, we have explored a wide range of electron energies and determined the conditions which best suit production. To extend the lifetime of the source we have developed an in situ cleaning method using only existing hardware. With these combinations, source life-times of >200 h for phosphorous and >100 h for boron ion beams have been achieved while maintaining 1100 cell-per-hour production.

  12. A high repetition rate XUV seeding source for FLASH2

    International Nuclear Information System (INIS)

    Willner, Arik

    2012-05-01

    Improved performance of free-electron laser (FEL) light sources in terms of timing stability, pulse shape and spectral properties of the amplified FEL pulses is of interest in material science, the fields of ultrafast dynamics, biology, chemistry and even special branches in industry. A promising scheme for such an improvement is direct seeding with high harmonic generation (HHG) in a noble gas target. A free-electron laser seeded by an external extreme ultraviolet (XUV) source is planned for FLASH2 at DESY in Hamburg. The requirements for the XUV/soft X-ray source can be summarized as follows: A repetition rate of at least 100 kHz in a 10 Hz burst is needed at variable wavelengths from 10 to 40 nm and pulse energies of several nJ within a single laser harmonic. This application requires a laser amplifier system with exceptional parameters, mJ-level pulse energy, 10-15 fs pulse duration at 100 kHz (1 MHz) burst repetition rate. A new optical parametric chirped-pulse amplification (OPCPA) system is under development in order to meet these requirements, and very promising results have been achieved in the last three years. In parallel to this development, a new HHG concept is necessary to sustain high average power of the driving laser system and to generate harmonics with high conversion efficiencies. Currently, the highest conversion efficiency with HHG has been demonstrated using gas-filled capillary targets. For our application, only a free-jet target can be used for HHG, in order to overcome damage threshold limitations of HHG target optics at a high repetition rate. A novel dual-gas multijet gas target has been developed and first experiments show remarkable control of the degree of phase matching forming the basis for improved control of the harmonic photon flux and the XUV pulse characteristics. The basic idea behind the dual-gas concept is the insertion of matching zones in between multiple HHG sources. These matching sections are filled with hydrogen which

  13. A high repetition rate XUV seeding source for FLASH2

    Energy Technology Data Exchange (ETDEWEB)

    Willner, Arik

    2012-05-15

    Improved performance of free-electron laser (FEL) light sources in terms of timing stability, pulse shape and spectral properties of the amplified FEL pulses is of interest in material science, the fields of ultrafast dynamics, biology, chemistry and even special branches in industry. A promising scheme for such an improvement is direct seeding with high harmonic generation (HHG) in a noble gas target. A free-electron laser seeded by an external extreme ultraviolet (XUV) source is planned for FLASH2 at DESY in Hamburg. The requirements for the XUV/soft X-ray source can be summarized as follows: A repetition rate of at least 100 kHz in a 10 Hz burst is needed at variable wavelengths from 10 to 40 nm and pulse energies of several nJ within a single laser harmonic. This application requires a laser amplifier system with exceptional parameters, mJ-level pulse energy, 10-15 fs pulse duration at 100 kHz (1 MHz) burst repetition rate. A new optical parametric chirped-pulse amplification (OPCPA) system is under development in order to meet these requirements, and very promising results have been achieved in the last three years. In parallel to this development, a new HHG concept is necessary to sustain high average power of the driving laser system and to generate harmonics with high conversion efficiencies. Currently, the highest conversion efficiency with HHG has been demonstrated using gas-filled capillary targets. For our application, only a free-jet target can be used for HHG, in order to overcome damage threshold limitations of HHG target optics at a high repetition rate. A novel dual-gas multijet gas target has been developed and first experiments show remarkable control of the degree of phase matching forming the basis for improved control of the harmonic photon flux and the XUV pulse characteristics. The basic idea behind the dual-gas concept is the insertion of matching zones in between multiple HHG sources. These matching sections are filled with hydrogen which

  14. High Brightness Neutron Source for Radiography. Final report

    International Nuclear Information System (INIS)

    Cremer, J.T.; Piestrup, Melvin A.; Gary, Charles K.; Harris, Jack L.; Williams, David J.; Jones, Glenn E.; Vainionpaa, J.H.; Fuller, Michael J.; Rothbart, George H.; Kwan, J.W.; Ludewigt, B.A.; Gough, R.A.; Reijonen, Jani; Leung, Ka-Ngo

    2008-01-01

    This research and development program was designed to improve nondestructive evaluation of large mechanical objects by providing both fast and thermal neutron sources for radiography. Neutron radiography permits inspection inside objects that x-rays cannot penetrate and permits imaging of corrosion and cracks in low-density materials. Discovering of fatigue cracks and corrosion in piping without the necessity of insulation removal is possible. Neutron radiography sources can provide for the nondestructive testing interests of commercial and military aircraft, public utilities and petrochemical organizations. Three neutron prototype neutron generators were designed and fabricated based on original research done at the Lawrence Berkeley National Laboratory (LBNL). The research and development of these generators was successfully continued by LBNL and Adelphi Technology Inc. under this STTR. The original design goals of high neutron yield and generator robustness have been achieved, using new technology developed under this grant. In one prototype generator, the fast neutron yield and brightness was roughly 10 times larger than previously marketed neutron generators using the same deuterium-deuterium reaction. In another generator, we integrate a moderator with a fast neutron source, resulting in a high brightness thermal neutron generator. The moderator acts as both conventional moderator and mechanical and electrical support structure for the generator and effectively mimics a nuclear reactor. In addition to the new prototype generators, an entirely new plasma ion source for neutron production was developed. First developed by LBNL, this source uses a spiral antenna to more efficiently couple the RF radiation into the plasma, reducing the required gas pressure so that the generator head can be completely sealed, permitting the possible use of tritium gas. This also permits the generator to use the deuterium-tritium reaction to produce 14-MeV neutrons with increases

  15. Influence of Spatial and Chromatic Noise on Luminance Discrimination.

    Science.gov (United States)

    Miquilini, Leticia; Walker, Natalie A; Odigie, Erika A; Guimarães, Diego Leite; Salomão, Railson Cruz; Lacerda, Eliza Maria Costa Brito; Cortes, Maria Izabel Tentes; de Lima Silveira, Luiz Carlos; Fitzgerald, Malinda E C; Ventura, Dora Fix; Souza, Givago Silva

    2017-12-05

    Pseudoisochromatic figures are designed to base discrimination of a chromatic target from a background solely on the chromatic differences. This is accomplished by the introduction of luminance and spatial noise thereby eliminating these two dimensions as cues. The inverse rationale could also be applied to luminance discrimination, if spatial and chromatic noise are used to mask those cues. In this current study estimate of luminance contrast thresholds were conducted using a novel stimulus, based on the use of chromatic and spatial noise to mask the use of these cues in a luminance discrimination task. This was accomplished by presenting stimuli composed of a mosaic of circles colored randomly. A Landolt-C target differed from the background only by the luminance. The luminance contrast thresholds were estimated for different chromatic noise saturation conditions and compared to luminance contrast thresholds estimated using the same target in a non-mosaic stimulus. Moreover, the influence of the chromatic content in the noise on the luminance contrast threshold was also investigated. Luminance contrast threshold was dependent on the chromaticity noise strength. It was 10-fold higher than thresholds estimated from non-mosaic stimulus, but they were independent of colour space location in which the noise was modulated. The present study introduces a new method to investigate luminance vision intended for both basic science and clinical applications.

  16. Science research with high-brilliance synchrotron light source

    International Nuclear Information System (INIS)

    Sanyal, Milan K.

    2013-01-01

    Synchrotron-science has changed dramatically since the development of high brilliance electron accelerator-based light sources in 1990s. In the last twenty years or so, several such facilities have come up, particularly in developed countries, as material characterizations in relevant atmosphere and protein crystallography with tiny-crystals have strong implications in industrial competitiveness. Moreover several new techniques have been developed recently over the entire spectral range of emitted light, from infra-red to high energy X-rays, which have altered our basic understanding of various materials like biomaterials, nanomaterials, soft-matter and semiconductor quantum structures. In addition, rapid development of various X-ray imaging techniques for nondestructive evaluation of compositional/structural homogeneity of engineering materials with nanometer resolution will have tremendous impact in manufacturing industries. As India becomes a developed country, it must have access to such an advanced synchrotron facility in the country that enables knowledge generation in the ever-expanding fields of design-characterization-production of advanced materials and modern medicines. Development of such state-of-the art facility will also enable us to carry out frontier-basic-research in our own country and help us to retain and bring back Indian talents to India. Here we shall discuss briefly the characteristics of a high brilliance synchrotron source and outline the nature of basic and applied science research that can be done with such a state-of-the-art facility. (author)

  17. Atomic physics at high brilliance synchrotron sources: Proceedings

    International Nuclear Information System (INIS)

    Berry, G.; Cowan, P.; Gemmell, D.

    1994-08-01

    This report contains papers on the following topics: present status of SPring-8 and the atomic physics undulator beamline; recent photoabsorption measurements in the rare gases and alkalis in the 3 to 15 keV proton energy region; atomic and molecular physics at LURE; experiments on atoms, ions and small molecules using the new generation of synchrotron radiation sources; soft x-ray fluorescence spectroscopy using tunable synchrotron radiation; soft x-ray fluorescence spectroscopy excited by synchrotron radiation: Inelastic and resonant scattering near threshold; outer-shell photoionization of ions; overview of the APS BESSRC beamline development; the advanced light source: Research opportunities in atomic and molecular physics; Photoionization of the Ba + ion by 4d shell excitation; decay dynamics of inner-shell excited atoms and molecules; absorption of atomic Ca, Cr, Mn and Cu; High-resolution photoelectron studies of resonant molecular photoionization; radiative and radiationless resonant raman scattering by synchrotron radiation; auger spectrometry of atoms and molecules; some thoughts of future experiments with the new generation of storage rings; Electron spectroscopy studies of argon K-shell excitation and vacancy cascades; ionization of atoms by high energy photons; ion coincidence spectroscopy on rare gas atoms and small molecules after photoexcitation at energies of several keV; an EBIS for use with synchrotron radiation photoionization of multiply charged ions and PHOBIS; gamma-2e coincidence measurements the wave of the future in inner-shell electron spectroscopy; recoil momentum spectroscopy in ion-atom and photon-atom collisions; a study of compton ionization of helium; future perspectives of photoionization studies at high photon energies; and status report on the advanced photon source. These papers have been cataloged separately elsewhere

  18. Asynchronous Learning Sources in a High-Tech Organization

    Science.gov (United States)

    Bouhnik, Dan; Giat, Yahel; Sanderovitch, Yafit

    2009-01-01

    Purpose: The purpose of this study is to characterize learning from asynchronous sources among research and development (R&D) personnel. It aims to examine four aspects of asynchronous source learning: employee preferences regarding self-learning; extent of source usage; employee satisfaction with these sources and the effect of the sources on the…

  19. An objective method for High Dynamic Range source content selection

    DEFF Research Database (Denmark)

    Narwaria, Manish; Mantel, Claire; Da Silva, Matthieu Perreira

    2014-01-01

    With the aim of improving the immersive experience of the end user, High Dynamic Range (HDR) imaging has been gaining popularity. Therefore, proper validation and performance benchmarking of HDR processing algorithms is a key step towards standardization and commercial deployment. A crucial...... component of such validation studies is the selection of a challenging and balanced set of source (reference) HDR content. In order to facilitate this, we present an objective method based on the premise that a more challenging HDR scene encapsulates higher contrast, and as a result will show up more...

  20. Computational methods for high-energy source shielding

    International Nuclear Information System (INIS)

    Armstrong, T.W.; Cloth, P.; Filges, D.

    1983-01-01

    The computational methods for high-energy radiation transport related to shielding of the SNQ-spallation source are outlined. The basic approach is to couple radiation-transport computer codes which use Monte Carlo methods and discrete ordinates methods. A code system is suggested that incorporates state-of-the-art radiation-transport techniques. The stepwise verification of that system is briefly summarized. The complexity of the resulting code system suggests a more straightforward code specially tailored for thick shield calculations. A short guide line to future development of such a Monte Carlo code is given

  1. High energy neutron source for materials research and development

    International Nuclear Information System (INIS)

    Odera, M.

    1989-01-01

    Requirements for neutron source for nuclear materials research are reviewed and ESNIT, Energy Selective Neutron Irradiation Test facility proposed by JAERI is discussed. Its principal aims of a wide neutron energy tunability and spectra peaking at each energy to enable characterization of material damage process are demanding but attractive goals which deserve detailed study. It is also to be noted that the requirements make a difference in facility design from those of FMIT, IFMIF and other high energy intense neutron sources built or planned to date. Areas of technologies to be addressed to realize the ESNIT facility are defined and discussed. In order to get neutron source having desired spectral characteristics keeping moderate intensity, projectile and target combinations must be examined including experimentation if necessary. It is also desired to minimize change of flux density and energy spectrum according to location inside irradiation chamber. Extended target or multiple targets configuration might be a solution as well as specimen rotation and choice of combination of projectile and target which has minimum velocity of the center of mass. Though relevant accelerator technology exists, it is to be stressed that considerable efforts must be paid, especially in the area of target and irradiation devices to get ESNIT goal. Design considerations to allow hands-on maintenance and future upgrading possibility are important either, in order to exploit the facility fully for nuclear materials research and development. (author)

  2. Discovery of GeV emission from the direction of the luminous infrared galaxy NGC 2146

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Qing-Wen; Wang, Xiang-Yu [School of Astronomy and Space Science, Nanjing University, Nanjing, 210093 (China); Thomas Tam, Pak-Hin, E-mail: xywang@nju.edu.cn, E-mail: phtam@phys.nthu.edu.tw [Institute of Astronomy and Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China)

    2014-10-10

    Recent detections of high-energy gamma-ray emission from starburst galaxies M82 and NGC 253 suggest that starburst galaxies are huge reservoirs of cosmic rays and these cosmic rays convert a significant fraction of their energy into gamma-rays by colliding with the dense interstellar medium. In this paper, we report the search for high-energy gamma-ray emission from several nearby star-forming and starburst galaxies using the 68 month data obtained with the Fermi Large Area Telescope. We found a ∼5.5σ detection of gamma-ray emission above 200 MeV from a source spatially coincident with the location of the luminous infrared galaxy NGC 2146. Also taking into account the temporal and spectral properties of the gamma-ray emission, we suggest that the gamma-ray source is likely to be the counterpart of NGC 2146. The gamma-ray luminosity suggests that cosmic rays in NGC 2146 convert most of their energy into secondary pions, so NGC 2146 is a 'proton calorimeter'. It is also found that NGC 2146 obeys the quasi-linear scaling relation between gamma-ray luminosity and total infrared luminosity for star-forming galaxies, strengthening the connection between massive star formation and gamma-ray emission of star-forming galaxies. Possible TeV emission from NGC 2146 is predicted and the implications for high-energy neutrino emission from starburst galaxies are discussed.

  3. SUPER-LUMINOUS TYPE Ic SUPERNOVAE: CATCHING A MAGNETAR BY THE TAIL

    International Nuclear Information System (INIS)

    Inserra, C.; Smartt, S. J.; Jerkstrand, A.; Fraser, M.; Wright, D.; Smith, K.; Chen, T.-W.; Kotak, R.; Nicholl, M.; Valenti, S.; Pastorello, A.; Benetti, S.; Bresolin, F.; Kudritzki, R. P.; Burgett, W. S.; Chambers, K. C.; Flewelling, H.; Botticella, M. T.; Ergon, M.; Fynbo, J. P. U.

    2013-01-01

    We report extensive observational data for five of the lowest redshift Super-Luminous Type Ic Supernovae (SL-SNe Ic) discovered to date, namely, PTF10hgi, SN2011ke, PTF11rks, SN2011kf, and SN2012il. Photometric imaging of the transients at +50 to +230 days after peak combined with host galaxy subtraction reveals a luminous tail phase for four of these SL-SNe. A high-resolution, optical, and near-infrared spectrum from xshooter provides detection of a broad He I λ10830 emission line in the spectrum (+50 days) of SN2012il, revealing that at least some SL-SNe Ic are not completely helium-free. At first sight, the tail luminosity decline rates that we measure are consistent with the radioactive decay of 56 Co, and would require 1-4 M ☉ of 56 Ni to produce the luminosity. These 56 Ni masses cannot be made consistent with the short diffusion times at peak, and indeed are insufficient to power the peak luminosity. We instead favor energy deposition by newborn magnetars as the power source for these objects. A semi-analytical diffusion model with energy input from the spin-down of a magnetar reproduces the extensive light curve data well. The model predictions of ejecta velocities and temperatures which are required are in reasonable agreement with those determined from our observations. We derive magnetar energies of 0.4 ∼ 51 erg) ∼ ej (M ☉ ) ∼< 8.6. The sample of five SL-SNe Ic presented here, combined with SN 2010gx—the best sampled SL-SNe Ic so far—points toward an explosion driven by a magnetar as a viable explanation for all SL-SNe Ic.

  4. Luminance gradient at object borders communicates object location to the human oculomotor system.

    Science.gov (United States)

    Kilpeläinen, Markku; Georgeson, Mark A

    2018-01-25

    The locations of objects in our environment constitute arguably the most important piece of information our visual system must convey to facilitate successful visually guided behaviour. However, the relevant objects are usually not point-like and do not have one unique location attribute. Relatively little is known about how the visual system represents the location of such large objects as visual processing is, both on neural and perceptual level, highly edge dominated. In this study, human observers made saccades to the centres of luminance defined squares (width 4 deg), which appeared at random locations (8 deg eccentricity). The phase structure of the square was manipulated such that the points of maximum luminance gradient at the square's edges shifted from trial to trial. The average saccade endpoints of all subjects followed those shifts in remarkable quantitative agreement. Further experiments showed that the shifts were caused by the edge manipulations, not by changes in luminance structure near the centre of the square or outside the square. We conclude that the human visual system programs saccades to large luminance defined square objects based on edge locations derived from the points of maximum luminance gradients at the square's edges.

  5. Active Luminous Blue Variables in the Large Magellanic Cloud

    Energy Technology Data Exchange (ETDEWEB)

    Walborn, Nolan R. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Gamen, Roberto C.; Lajús, Eduardo Fernández [Instituto de Astrofísica de La Plata, CONICET–UNLP and Facultad de Ciencias Astronómicas y Geofísicas, UNLP, Paseo del Bosque s/n, La Plata (Argentina); Morrell, Nidia I. [Las Campanas Observatory, Carnegie Observatories, Casilla 601, La Serena (Chile); Barbá, Rodolfo H. [Departamento de Física y Astronomía, Universidad de La Serena, Cisternas 1200 Norte, La Serena (Chile); Angeloni, Rodolfo, E-mail: walborn@stsci.edu, E-mail: rgamen@fcaglp.unlp.edu.ar, E-mail: eflajus@fcaglp.unlp.edu.ar, E-mail: nmorrell@lco.cl, E-mail: rbarba@dfuls.cl, E-mail: rangelon@gemini.edu [Gemini Observatory, Colina El Pino, Casilla 603, La Serena (Chile)

    2017-07-01

    We present extensive spectroscopic and photometric monitoring of two famous and currently highly active luminous blue variables (LBVs) in the Large Magellanic Cloud (LMC), together with more limited coverage of three further, lesser known members of the class. R127 was discovered as an Ofpe/WN9 star in the 1970s but entered a classical LBV outburst in or about 1980 that is still in progress, thus enlightening us about the minimum state of such objects. R71 is currently the most luminous star in the LMC and continues to provide surprises, such as the appearance of [Ca ii] emission lines, as its spectral type becomes unprecedentedly late. Most recently, R71 has developed inverse P Cyg profiles in many metal lines. The other objects are as follows: HDE 269582, now a “second R127” that has been followed from Ofpe/WN9 to A type in its current outburst; HDE 269216, which changed from late B in 2014 to AF in 2016, its first observed outburst; and R143 in the 30 Doradus outskirts. The light curves and spectroscopic transformations are correlated in remarkable detail and their extreme reproducibility is emphasized, both for a given object and among all of them. It is now believed that some LBVs proceed directly to core collapse. One of these unstable LMC objects may thus oblige in the near future, teaching us even more about the final stages of massive stellar evolution.

  6. Effect of americium-241 on luminous bacteria. Role of peroxides

    Energy Technology Data Exchange (ETDEWEB)

    Alexandrova, M., E-mail: maka-alexandrova@rambler.r [Siberian Federal University, Svobodny 79, 660041 Krasnoyarsk (Russian Federation); Rozhko, T. [Siberian Federal University, Svobodny 79, 660041 Krasnoyarsk (Russian Federation); Vydryakova, G. [Institute of Biophysics SB RAS, Akademgorodok 50, 660036 Krasnoyarsk (Russian Federation); Kudryasheva, N. [Siberian Federal University, Svobodny 79, 660041 Krasnoyarsk (Russian Federation); Institute of Biophysics SB RAS, Akademgorodok 50, 660036 Krasnoyarsk (Russian Federation)

    2011-04-15

    The effect of americium-241 ({sup 241}Am), an alpha-emitting radionuclide of high specific activity, on luminous bacteria Photobacterium phosphoreum was studied. Traces of {sup 241}Am in nutrient media (0.16-6.67 kBq/L) suppressed the growth of bacteria, but enhanced luminescence intensity and quantum yield at room temperature. Lower temperature (4 {sup o}C) increased the time of bacterial luminescence and revealed a stage of bioluminescence inhibition after 150 h of bioluminescence registration start. The role of conditions of exposure the bacterial cells to the {sup 241}Am is discussed. The effect of {sup 241}Am on luminous bacteria was attributed to peroxide compounds generated in water solutions as secondary products of radioactive decay. Increase of peroxide concentration in {sup 241}Am solutions was demonstrated; and the similarity of {sup 241}Am and hydrogen peroxide effects on bacterial luminescence was revealed. The study provides a scientific basis for elaboration of bioluminescence-based assay to monitor radiotoxicity of alpha-emitting radionuclides in aquatic solutions. - Highlights: {yields} Am-241 in water solutions (A = 0.16-6.7 kBq/L) suppresses bacterial growth.{yields} Am-241 (A = 0.16-6.7 kBq/L) stimulate bacterial luminescence. {yields} Peroxides, secondary radiolysis products, cause increase of bacterial luminescence.

  7. Luminal digestion of lactoferrin in suckling and weanling rats

    International Nuclear Information System (INIS)

    Britton, J.R.; Koldovsky, O.

    1987-01-01

    The development of luminal digestion of lactoferrin was evaluated in vitro by incubating 125 I-labeled lactoferrin with fluid flushed from the stomach and small intestine of 12-day-old suckling and 31-day-old weanling rats, followed by measurement of radioactivity in trichloroacetic acid-soluble material. Gastric hydrolysis of lactoferrin at pH 3.2 in the weanling was 20-fold greater than that in the suckling. In the small intestine at neutral pH, luminal degradation of lactoferrin was minimal in the suckling but increased significantly after weaning, with maximal degradative capacity demonstrable in the midjejunum. Sephadex G-75 chromatography of intestinal acid-soluble breakdown products revealed two peaks of radioactivity, each comprising 40-45% of the total product; analysis of intestinal acid-precipitable products by polyacrylamide gel electrophoresis yielded several discrete lower molecular weight species. Food deprivation for 12 h/100 g body wt decreased lactoferrin degradation in the weanling jejunum and midjejunum. The findings suggest that lactoferrin digestion may vary with respect to postnatal age of the organism, segment of the gastrointestinal tract, and dietary state. In the young animal, lactoferrin degradation is minimal, and consequently its potential for biological function may be high

  8. Active Luminous Blue Variables in the Large Magellanic Cloud

    Science.gov (United States)

    Walborn, Nolan R.; Gamen, Roberto C.; Morrell, Nidia I.; Barbá, Rodolfo H.; Fernández Lajús, Eduardo; Angeloni, Rodolfo

    2017-07-01

    We present extensive spectroscopic and photometric monitoring of two famous and currently highly active luminous blue variables (LBVs) in the Large Magellanic Cloud (LMC), together with more limited coverage of three further, lesser known members of the class. R127 was discovered as an Ofpe/WN9 star in the 1970s but entered a classical LBV outburst in or about 1980 that is still in progress, thus enlightening us about the minimum state of such objects. R71 is currently the most luminous star in the LMC and continues to provide surprises, such as the appearance of [Ca II] emission lines, as its spectral type becomes unprecedentedly late. Most recently, R71 has developed inverse P Cyg profiles in many metal lines. The other objects are as follows: HDE 269582, now a “second R127” that has been followed from Ofpe/WN9 to A type in its current outburst; HDE 269216, which changed from late B in 2014 to AF in 2016, its first observed outburst; and R143 in the 30 Doradus outskirts. The light curves and spectroscopic transformations are correlated in remarkable detail and their extreme reproducibility is emphasized, both for a given object and among all of them. It is now believed that some LBVs proceed directly to core collapse. One of these unstable LMC objects may thus oblige in the near future, teaching us even more about the final stages of massive stellar evolution.

  9. Active Luminous Blue Variables in the Large Magellanic Cloud

    International Nuclear Information System (INIS)

    Walborn, Nolan R.; Gamen, Roberto C.; Lajús, Eduardo Fernández; Morrell, Nidia I.; Barbá, Rodolfo H.; Angeloni, Rodolfo

    2017-01-01

    We present extensive spectroscopic and photometric monitoring of two famous and currently highly active luminous blue variables (LBVs) in the Large Magellanic Cloud (LMC), together with more limited coverage of three further, lesser known members of the class. R127 was discovered as an Ofpe/WN9 star in the 1970s but entered a classical LBV outburst in or about 1980 that is still in progress, thus enlightening us about the minimum state of such objects. R71 is currently the most luminous star in the LMC and continues to provide surprises, such as the appearance of [Ca ii] emission lines, as its spectral type becomes unprecedentedly late. Most recently, R71 has developed inverse P Cyg profiles in many metal lines. The other objects are as follows: HDE 269582, now a “second R127” that has been followed from Ofpe/WN9 to A type in its current outburst; HDE 269216, which changed from late B in 2014 to AF in 2016, its first observed outburst; and R143 in the 30 Doradus outskirts. The light curves and spectroscopic transformations are correlated in remarkable detail and their extreme reproducibility is emphasized, both for a given object and among all of them. It is now believed that some LBVs proceed directly to core collapse. One of these unstable LMC objects may thus oblige in the near future, teaching us even more about the final stages of massive stellar evolution.

  10. SHARDS: Survey for High-z Absorption Red & Dead Sources

    Science.gov (United States)

    Pérez-González, P. G.; Cava, A.

    2013-05-01

    SHARDS, an ESO/GTC Large Program, is an ultra-deep (26.5 mag) spectro-photometric survey with GTC/OSIRIS designed to select and study massive passively evolving galaxies at z=1.0-2.3 in the GOODS-N field using a set of 24 medium-band filters (FWHM~17 nm) covering the 500-950 nm spectral range. Our observing strategy has been planned to detect, for z>1 sources, the prominent Mg absorption feature (at rest-frame ~280 nm), a distinctive, necessary, and sufficient feature of evolved stellar populations (older than 0.5 Gyr). These observations are being used to: (1) derive for the first time an unbiased sample of high-z quiescent galaxies, which extends to fainter magnitudes the samples selected with color techniques and spectroscopic surveys; (2) derive accurate ages and stellar masses based on robust measurements of spectral features such as the Mg_UV or D(4000) indices; (3) measure their redshift with an accuracy Δz/(1+z)<0.02; and (4) study emission-line galaxies (starbursts and AGN) up to very high redshifts. The well-sampled optical SEDs provided by SHARDS for all sources in the GOODS-N field are a valuable complement for current and future surveys carried out with other telescopes (e.g., Spitzer, HST, and Herschel).

  11. Effects of absolute luminance and luminance contrast on visual search in low mesopic environments.

    Science.gov (United States)

    Hunter, Mathew; Godde, Ben; Olk, Bettina

    2018-03-26

    Diverse adaptive visual processing mechanisms allow us to complete visual search tasks in a wide visual photopic range (>0.6 cd/m 2 ). Whether search strategies or mechanisms known from this range extend below, in the mesopic and scotopic luminance spectra (search in more complex-feature and conjunction-search paradigms. The results verify the previously reported deficiency windows defined by an interaction of base luminance and luminance contrast for more complex visual-search tasks. Based on significant regression analyses, a more precise definition of the magnitude of contribution of different contrast parameters. Characterized feature search patterns had approximately a 2.5:1 ratio of contribution from the Michelson contrast property relative to Weber contrast, whereas the ratio was approximately 1:1 in a serial-search condition. The results implicate near-complete magnocellular isolation in a visual-search paradigm that has yet to be demonstrated. Our analyses provide a new method of characterizing visual search and the first insight in its underlying mechanisms in luminance environments in the low mesopic and scotopic spectra.

  12. Standard deviation of luminance distribution affects lightness and pupillary response.

    Science.gov (United States)

    Kanari, Kei; Kaneko, Hirohiko

    2014-12-01

    We examined whether the standard deviation (SD) of luminance distribution serves as information of illumination. We measured the lightness of a patch presented in the center of a scrambled-dot pattern while manipulating the SD of the luminance distribution. Results showed that lightness decreased as the SD of the surround stimulus increased. We also measured pupil diameter while viewing a similar stimulus. The pupil diameter decreased as the SD of luminance distribution of the stimuli increased. We confirmed that these results were not obtained because of the increase of the highest luminance in the stimulus. Furthermore, results of field measurements revealed a correlation between the SD of luminance distribution and illuminance in natural scenes. These results indicated that the visual system refers to the SD of the luminance distribution in the visual stimulus to estimate the scene illumination.

  13. Luminance cues constrain chromatic blur discrimination in natural scene stimuli.

    Science.gov (United States)

    Sharman, Rebecca J; McGraw, Paul V; Peirce, Jonathan W

    2013-03-22

    Introducing blur into the color components of a natural scene has very little effect on its percept, whereas blur introduced into the luminance component is very noticeable. Here we quantify the dominance of luminance information in blur detection and examine a number of potential causes. We show that the interaction between chromatic and luminance information is not explained by reduced acuity or spatial resolution limitations for chromatic cues, the effective contrast of the luminance cue, or chromatic and achromatic statistical regularities in the images. Regardless of the quality of chromatic information, the visual system gives primacy to luminance signals when determining edge location. In natural viewing, luminance information appears to be specialized for detecting object boundaries while chromatic information may be used to determine surface properties.

  14. SURVEY OF THE ENTOMOFAUNA THROUGH LUMINOUS TRAP

    Directory of Open Access Journals (Sweden)

    V. R. Andrade Neto

    2014-09-01

    Full Text Available The demand for forest-based raw materials for energy, construction, paper pulp and the pressure to comply with legal requirements concerning environmental legislation, for example, the replacement of the permanent preservation area, legal reserve and recovery of degraded area, leads to encourage the production of healthy seedlings in a health status to do not compromise their future production. The present study aimed to survey the entomofauna population using the “Luiz de Queiroz” model of luminous trap, with white and red fluorescent lamps. The experiment was conducted at the nursery “Flora Sinop” in Sinop – MT. The survey was conducted weekly between the months of April to July 2010, totaling 4 months sand, 32 samples collected. The orders Hemiptera and Coleoptera showed the highest number of individuals captured, either in attraction with white or red light. It was captured 10.089 individuals, 9.339 collected under the influence of white light, representing 92,56%, and 750 with red light, only 7,44% of the total. The white light luminous trap possessed greater efficiency in the attraction of insects when compared with the red light trap.

  15. High Current, High Density Arc Plasma as a New Source for WiPAL

    Science.gov (United States)

    Waleffe, Roger; Endrizzi, Doug; Myers, Rachel; Wallace, John; Clark, Mike; Forest, Cary; WiPAL Team

    2016-10-01

    The Wisconsin Plasma Astrophysics Lab (WiPAL) has installed a new array of nineteen plasma sources (plasma guns) on its 3 m diameter, spherical vacuum vessel. Each gun is a cylindrical, molybdenum, washer-stabilized, arc plasma source. During discharge, the guns are maintained at 1.2 kA across 100 V for 10 ms by the gun power supply establishing a high density plasma. Each plasma source is fired independently allowing for adjustable plasma parameters, with densities varying between 1018 -1019 m-3 and electron temperatures of 5-15 eV. Measurements were characterized using a 16 tip Langmuir probe. The plasma source will be used as a background plasma for the magnetized coaxial plasma gun (MCPG), the Terrestrial Reconnection Experiment (TREX), and as the plasma source for a magnetic mirror experiment. Temperature, density, and confinement results will be presented. This work is supported by the DoE and the NSF.

  16. A far-infrared spectroscopic survey of intermediate redshift (ultra) luminous infrared galaxies

    International Nuclear Information System (INIS)

    Magdis, Georgios E.; Rigopoulou, D.; Hopwood, R.; Clements, D.; Huang, J.-S.; Farrah, D.; Pearson, C.; Alonso-Herrero, Almudena; Bock, J. J.; Cooray, A.; Griffin, M. J.; Oliver, S.; Perez Fournon, I.; Riechers, D.; Swinyard, B. M.; Thatte, N.; Scott, D.; Valtchanov, I.; Vaccari, M.

    2014-01-01

    We present Herschel far-IR photometry and spectroscopy as well as ground-based CO observations of an intermediate redshift (0.21 ≤ z ≤ 0.88) sample of Herschel-selected (ultra)-luminous infrared galaxies (L IR > 10 11.5 L ☉ ). With these measurements, we trace the dust continuum, far-IR atomic line emission, in particular [C II] 157.7 μm, as well as the molecular gas of z ∼ 0.3 luminous and ultraluminous infrared galaxies (LIRGs and ULIRGs) and perform a detailed investigation of the interstellar medium of the population. We find that the majority of Herschel-selected intermediate redshift (U)LIRGs have L C II /L FIR ratios that are a factor of about 10 higher than that of local ULIRGs and comparable to that of local normal and high-z star-forming galaxies. Using our sample to bridge local and high-z [C II] observations, we find that the majority of galaxies at all redshifts and all luminosities follow an L C II –L FIR relation with a slope of unity, from which local ULIRGs and high- z active-galactic-nucleus-dominated sources are clear outliers. We also confirm that the strong anti-correlation between the L C II /L FIR ratio and the far-IR color L 60 /L 100 observed in the local universe holds over a broad range of redshifts and luminosities, in the sense that warmer sources exhibit lower L C II /L FIR at any epoch. Intermediate redshift ULIRGs are also characterized by large molecular gas reservoirs and by lower star formation efficiencies compared to that of local ULIRGs. The high L C II /L FIR ratios, the moderate star formation efficiencies (L IR /L CO ′ or L IR /M H 2 ), and the relatively low dust temperatures of our sample (which are also common characteristics of high-z star-forming galaxies with ULIRG-like luminosities) indicate that the evolution of the physical properties of (U)LIRGs between the present day and z > 1 is already significant by z ∼ 0.3.

  17. Relationship of the luminous bacterial symbiont of the Caribbean flashlight fish, Kryptophanaron alfredi (family Anomalopidae) to other luminous bacteria based on bacterial luciferase (luxA) genes.

    Science.gov (United States)

    Haygood, M G

    1990-01-01

    Flashlight fishes (family Anomalopidae) have light organs that contain luminous bacterial symbionts. Although the symbionts have not yet been successfully cultured, the luciferase genes have been cloned directly from the light organ of the Caribbean species, Kryptophanaron alfredi. The goal of this project was to evaluate the relationship of the symbiont to free-living luminous bacteria by comparison of genes coding for bacterial luciferase (lux genes). Hybridization of a lux AB probe from the Kryptophanaron alfredi symbiont to DNAs from 9 strains (8 species) of luminous bacteria showed that none of the strains tested had lux genes highly similar to the symbiont. The most similar were a group consisting of Vibrio harveyi, Vibrio splendidus and Vibrio orientalis. The nucleotide sequence of the luciferase alpha subunit gene luxA) of the Kryptophanaron alfredi symbiont was determined in order to do a more detailed comparison with published luxA sequences from Vibrio harveyi, Vibrio fischeri and Photobacterium leiognathi. The hybridization results, sequence comparisons and the mol% G + C of the Kryptophanaron alfredi symbiont luxA gene suggest that the symbiont may be considered as a new species of luminous Vibrio related to Vibrio harveyi.

  18. Luminance and image quality analysis of an organic electroluminescent panel with a patterned microlens array attachment

    International Nuclear Information System (INIS)

    Lin, Hoang Yan; Chen, Kuan-Yu; Ho, Yu-Hsuan; Fang, Jheng-Hao; Hsu, Sheng-Chih; Lee, Jiun-Haw; Lin, Jia-Rong; Wei, Mao-Kuo

    2010-01-01

    Luminance and image quality observed from the normal direction of a commercial 2.0 inch panel based on organic electroluminescence (OEL) technology attached to regular and patterned microlens array films (MAFs) were studied and analyzed. When applying the regularly arranged MAF on the panel, a luminance enhancement of 23% was observed, accompanied by a reduction of the image quality index as low as 74%. By removing the microlenses on the emitting areas, the patterned MAF enhances the luminance efficiency of the OEL by 52% keeping the image quality index of the display as high as 94%, due to the effective light extraction in the glass substrate being less than the critical angle. 3D simulation based on a ray-tracing model was also established to investigate the spatial distribution of light rays radiated from an OEL pixel with different microstructures which showed consistent results with the experimental results

  19. Environmental radioactive monitoring, evaluation and protection in luminous workshops of a factory

    International Nuclear Information System (INIS)

    Dai Hanbin; Xiang Ming; Tan Jianzu

    2009-01-01

    Fluorescent technique is often used to display instrumental indicator in the dark environment. Luminous workshops of a factory smear and depict the glassware by means of fluorescent power with adulterated radioactive matter. Because of adulterated radioactive matters such as 226 Ra, 40 K emit alpha-ray,beta-ray and gamma-ray, while they decay spontaneously, and high dose or cumulative radiation can damage human body in different degrees. Therefore, any radioactive damage to human body caused by over-safety dose should be prevented strictly during the working. To ensure health and safety of working staff in luminous workshop and the public, it is necessary to regularly have radioactive monitoring and evaluation to luminous workshop and its surrounding environment. Through the environment radioactive monitoring, the authors analyze its environmental radioactive level,and try to find out the possible problems so as to propose some protective measures for personal health. (authors)

  20. Development of a high brightness, high current SRF photo-electron source for ERL applications

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Axel [Helmholtz-Zentrum Berlin (Germany); Collaboration: bERLinPro Team

    2016-07-01

    Energy recovery linacs (ERL) offer the potential to combine major beam properties of the two main domains of particle accelerators: The low emittance of linear accelerators and the high average beam current of storage rings, while also allowing to compress to short bunches below the ps regime. This makes among other applications ERLs an ideal candidate for future light sources. The beam properties of the ERL are given by the performance of the injection section and hence of the beam source. Helmholtz-Zentrum Berlin is currently designing and building a high average current all superconducting CW driven ERL as a prototype to demonstrate low normalized beam emittance of 1 mm*mrad at 100 mA and short pulses of about 2 ps. In this contribution we discuss the development of this class of a high brightness, high current SRF photo-electron source and present recent commissioning results. Also, alternative approaches at other laboratories are shortly reviewed.

  1. Alma observations of nearby luminous infrared galaxies with various agn energetic contributions using dense gas tracers

    Energy Technology Data Exchange (ETDEWEB)

    Imanishi, Masatoshi [Subaru Telescope, 650 North A' ohoku Place, Hilo, HI 96720 (United States); Nakanishi, Kouichiro, E-mail: masa.imanishi@nao.ac.jp [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan)

    2014-07-01

    We present the results of our ALMA Cycle 0 observations, using HCN/HCO{sup +}/HNC J = 4-3 lines, of six nearby luminous infrared galaxies with various energetic contributions from active galactic nuclei (AGNs) estimated from previous infrared spectroscopy. These lines are very effective for probing the physical properties of high-density molecular gas around the hidden energy sources in the nuclear regions of these galaxies. We find that HCN to HCO{sup +} J = 4-3 flux ratios tend to be higher in AGN-important galaxies than in starburst-dominated regions, as was seen at the J = 1-0 transition, while there is no clear difference in the HCN-to-HNC J = 4-3 flux ratios among observed sources. A galaxy with a starburst-type infrared spectral shape and very large molecular line widths shows a high HCN-to-HCO{sup +} J = 4-3 flux ratio, which could be due to turbulence-induced heating. We propose that enhanced HCN J = 4-3 emission relative to HCO{sup +} J = 4-3 could be used to detect more energetic activity than normal starbursts, including deeply buried AGNs, in dusty galaxy populations.

  2. Interferometric follow-up of WISE hyper-luminous hot, dust-obscured galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jingwen; Wright, Edward L. [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States); Bussmann, R. Shane [Harvard-Smithsonian Center for Astrophysics, 60 Garden St., MS78, Cambridge, MA 02138 (United States); Tsai, Chao-Wei; Eisenhardt, Peter R. M.; Stern, Daniel; Moustakas, Leonidas [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Dr., Pasadena, CA 91109 (United States); Petric, Andreea [Institute for Astronomy, 2680 Woodlawn Drive, Honolulu, HI 96822-1839 (United States); Blain, Andrew [Department of Physics and Astronomy, University of Leicester, Leicester, LE1 7RH (United Kingdom); Bridge, Carrie R. [Division of Physics, Math, and Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); Benford, Dominic J. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Assef, Roberto J. [Núcleo de Astronomía de la Facultad de Ingeniería, Universidad Diego Portales, Av., Santiago, Ejército Libertador 441 (Chile); Gelino, Christopher R., E-mail: jingwen@astro.ucla.edu [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States)

    2014-09-20

    The Wide-field Infrared Survey Explorer (WISE) has discovered an extraordinary population of hyper-luminous dusty galaxies that are faint in the two bluer passbands (3.4 μm and 4.6 μm) but are bright in the two redder passbands of WISE (12 μm and 22 μm). We report on initial follow-up observations of three of these hot, dust-obscured galaxies, or Hot DOGs, using the Combined Array for Research in Millimeter-wave Astronomy and the Submillimeter Array interferometer arrays at submillimeter/millimeter wavelengths. We report continuum detections at ∼1.3 mm of two sources (WISE J014946.17+235014.5 and WISE J223810.20+265319.7, hereafter W0149+2350 and W2238+2653, respectively), and upper limits to CO line emission at 3 mm in the observed frame for two sources (W0149+2350 and WISE J181417.29+341224.8, hereafter W1814+3412). The 1.3 mm continuum images have a resolution of 1''-2'' and are consistent with single point sources. We estimate the masses of cold dust are 2.0 × 10{sup 8} M {sub ☉} for W0149+2350 and 3.9 × 10{sup 8} M {sub ☉} for W2238+2653, comparable to cold dust masses of luminous quasars. We obtain 2σ upper limits to the molecular gas masses traced by CO, which are 3.3 × 10{sup 10} M {sub ☉} and 2.3 × 10{sup 10} M {sub ☉} for W0149+2350 and W1814+3412, respectively. We also present high-resolution, near-IR imaging with the WFC3 on the Hubble Space Telescope for W0149+2653 and with NIRC2 on Keck for W2238+2653. The near-IR images show morphological structure dominated by a single, centrally condensed source with effective radius less than 4 kpc. No signs of gravitational lensing are evident.

  3. The coordination of problem solving strategies: when low competence sources exert more influence on task processing than high competence sources.

    Science.gov (United States)

    Quiamzade, Alain; Mugny, Gabriel; Darnon, Céline

    2009-03-01

    Previous research has shown that low competence sources, compared to highly competent sources, can exert influence in aptitudes tasks in as much as they induce people to focus on the task and to solve it more deeply. Two experiments aimed at testing the coordination between self and source's problem solving strategies as a main explanation of such a difference in influence. The influence of a low versus high competence source has been examined in an anagram task that allows for distinguishing between three response strategies, including one that corresponds to the coordination between the source's strategy and participants' own strategy. In Study 1 the strategy suggested by the source was either relevant and useful or irrelevant and useless for solving the task. Results indicated that participants used the coordination strategy in a larger extend when they had been confronted to a low competence rather than a highly competent source but only when the source displayed a strategy that was useful to solve the task. In Study 2 the source's strategy was always relevant and useful, but a decentring procedure was introduced for half of the participants. This procedure induced participants to consider other points of view than their own. Results replicated the difference observed in Study 1 when no decentring was introduced. The difference however disappeared when decentring was induced, because of an increase of the high competence source's influence. These results highlight coordination of strategies as one mechanism underlying influence from low competence sources.

  4. Pulsars as the sources of high energy cosmic ray positrons

    International Nuclear Information System (INIS)

    Hooper, Dan; Blasi, Pasquale; Serpico, Pasquale Dario

    2009-01-01

    Recent results from the PAMELA satellite indicate the presence of a large flux of positrons (relative to electrons) in the cosmic ray spectrum between approximately 10 and 100 GeV. As annihilating dark matter particles in many models are predicted to contribute to the cosmic ray positron spectrum in this energy range, a great deal of interest has resulted from this observation. Here, we consider pulsars (rapidly spinning, magnetized neutron stars) as an alternative source of this signal. After calculating the contribution to the cosmic ray positron and electron spectra from pulsars, we find that the spectrum observed by PAMELA could plausibly originate from such sources. In particular, a significant contribution is expected from the sum of all mature pulsars throughout the Milky Way, as well as from the most nearby mature pulsars (such as Geminga and B0656+14). The signal from nearby pulsars is expected to generate a small but significant dipole anisotropy in the cosmic ray electron spectrum, potentially providing a method by which the Fermi gamma-ray space telescope would be capable of discriminating between the pulsar and dark matter origins of the observed high energy positrons

  5. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  6. A high-current pulsed cathodic vacuum arc plasma source

    International Nuclear Information System (INIS)

    Oates, T.W.H.; Pigott, J.; Mckenzie, D.R.; Bilek, M.M.M.

    2003-01-01

    Cathodic vacuum arcs (CVAs) are well established as a method for producing metal plasmas for thin film deposition and as a source of metal ions. Fundamental differences exist between direct current (dc) and pulsed CVAs. We present here results of our investigations into the design and construction of a high-current center-triggered pulsed CVA. Power supply design based on electrolytic capacitors is discussed and optimized based on obtaining the most effective utilization of the cathode material. Anode configuration is also discussed with respect to the optimization of the electron collection capability. Type I and II cathode spots are observed and discussed with respect to cathode surface contamination. An unfiltered deposition rate of 1.7 nm per pulse, at a distance of 100 mm from the source, has been demonstrated. Instantaneous plasma densities in excess of 1x10 19 m -3 are observed after magnetic filtering. Time averaged densities an order of magnitude greater than common dc arc densities have been demonstrated, limited by pulse repetition rate and filter efficiency

  7. ["Glare vision". I. Physiological principles of vision change with increased test field luminance].

    Science.gov (United States)

    Hauser, B; Ochsner, H; Zrenner, E

    1992-02-01

    Clinical tests of visual acuity are an important measure of visual function. However visual acuity is usually determined only in narrow range of luminance levels between 160 and 320 cd/m2; therefore losses of visual acuity in other ranges of light intensity can not be detected. In a distance of 80 cm from the patients eyes, Landolt rings of varying sizes were presented on a small test field whose light intensity can be varied between 0.1 and 30,000 cd/m2. Thereby an acuity-luminance-function can be obtained. We studied such functions under different conditions of exposure time both with constant and with increasing luminance of the test field. We found that persons with normal vision can increase their visual acuity with increasing test field luminance up to a range of 5000 cd/m2. The maximum values of visual acuity under optimal lightening conditions lie (varying with age) between 2.2 and 0.9. Under pathological conditions visual acuity falls at high luminances accompanied by sensations of glare. Tests of glare sensitivity as a function of exposure time showed 4 sec to be a critical time of exposure since after 4 sec normal persons just reach their maximum visual acuity at high luminances. The underlying physiological mechanisms lead us to suppose that patients with neuronal light adaptation disturbances display a greater visual loss as a result of decreased time of exposure than those with disturbances in the ocular media. Visual acuity as well as the capacity to increase the patients visual acuity under optimal conditions of lighting were both found to be strongly age-dependent.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. High intensity neutrino source superconducting solenoid cyrostat design

    Energy Technology Data Exchange (ETDEWEB)

    Page, T.M.; Nicol, T.H.; Feher, S.; Terechkine, I.; Tompkins, J.; /Fermilab

    2006-06-01

    Fermi National Accelerator Laboratory (FNAL) is involved in the development of a 100 MeV superconducting linac. This linac is part of the High Intensity Neutrino Source (HINS) R&D Program. The initial beam acceleration in the front end section of the linac is achieved using room temperature spoke cavities, each of which is combined with a superconducting focusing solenoid. These solenoid magnets are cooled with liquid helium at 4.5K, operate at 250 A and have a maximum magnetic field strength of 7.5 T. The solenoid cryostat will house the helium vessel, suspension system, thermal shield, multilayer insulation, power leads, instrumentation, a vacuum vessel and cryogenic distribution lines. This paper discusses the requirements and detailed design of these superconducting solenoid cryostats.

  9. Calibration of {sup 192}Ir high dose rate brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Marechal, M H [Instituto de Radioprotecao e Dozimetria, Rio de Jainero (Brazil); Almeida, C.E. de [Laboratorio de Ciencias Radiologicas, UERL, Rio de Janeiro (Brazil); Sibata, C H [Roswell Park Cancer Inst., Buffalo, NY (United States)

    1996-08-01

    A method for calibration of high dose rate sources used in afterloading brachytherapy systems is described. The calibration for {sup 192}Ir is determined by interpolating {sup 60}Co gamma-rays and 250 kV x-rays calibration factors. All measurements were done using the same build up caps as described by Goetsch et al and recommended by AAPM. The attenuation correction factors were determined to be 0.9903, 0.9928 and 0.9993 for {sup 192}Ir, {sup 60}Co and 250 kV x-ray, respectively. A wall + cap thickness of 0.421 g.cm{sup -2} is recommended for all measurements to ensure electronic equilibrium for {sup 60}Co and {sup 192}Ir gamma-ray beams. A mathematical formalism is described for determination of (N{sub x}){sub Ir}. (author). 5 refs, 1 fig.

  10. Miniaturized High-Speed Modulated X-Ray Source

    Science.gov (United States)

    Gendreau, Keith C. (Inventor); Arzoumanian, Zaven (Inventor); Kenyon, Steven J. (Inventor); Spartana, Nick Salvatore (Inventor)

    2015-01-01

    A miniaturized high-speed modulated X-ray source (MXS) device and a method for rapidly and arbitrarily varying with time the output X-ray photon intensities and energies. The MXS device includes an ultraviolet emitter that emits ultraviolet light, a photocathode operably coupled to the ultraviolet light-emitting diode that emits electrons, an electron multiplier operably coupled to the photocathode that multiplies incident electrons, and an anode operably coupled to the electron multiplier that is configured to produce X-rays. The method for modulating MXS includes modulating an intensity of an ultraviolet emitter to emit ultraviolet light, generating electrons in response to the ultraviolet light, multiplying the electrons to become more electrons, and producing X-rays by an anode that includes a target material configured to produce X-rays in response to impact of the more electrons.

  11. Handling high data rate detectors at Diamond Light Source

    Science.gov (United States)

    Pedersen, U. K.; Rees, N.; Basham, M.; Ferner, F. J. K.

    2013-03-01

    An increasing number of area detectors, in use at Diamond Light Source, produce high rates of data. In order to capture, store and process this data High Performance Computing (HPC) systems have been implemented. This paper will present the architecture and usage for handling high rate data: detector data capture, large volume storage and parallel processing. The EPICS area Detector frame work has been adopted to abstract the detectors for common tasks including live processing, file format and storage. The chosen data format is HDF5 which provides multidimensional data storage and NeXuS compatibility. The storage system and related computing infrastructure include: a centralised Lustre based parallel file system, a dedicated network and a HPC cluster. A well defined roadmap is in place for the evolution of this to meet demand as the requirements and technology advances. For processing the science data the HPC cluster allow efficient parallel computing, on a mixture of ×86 and GPU processing units. The nature of the Lustre storage system in combination with the parallel HDF5 library allow efficient disk I/O during computation jobs. Software developments, which include utilising optimised parallel file reading for a variety of post processing techniques, are being developed in collaboration as part of the Pan-Data EU Project (www.pan-data.eu). These are particularly applicable to tomographic reconstruction and processing of non crystalline diffraction data.

  12. Fabrication of high rate chromium getter sources for fusion applications

    International Nuclear Information System (INIS)

    Gabbard, W.A.; Simpkins, J.E.; Mioduszewski, P.; Edmonds, P.H.

    1983-01-01

    Design and fabrication techniques are described for the manufacture of large-capacity chromium getter sources, analogous to the commercially available titanium getter source known as Ti-Ball, manufactured by Varian Associates

  13. Chromatic blur perception in the presence of luminance contrast.

    Science.gov (United States)

    Jennings, Ben J; Kingdom, Frederick A A

    2017-06-01

    Hel-Or showed that blurring the chromatic but not the luminance layer of an image of a natural scene failed to elicit any impression of blur. Subsequent studies have suggested that this effect is due either to chromatic blur being masked by spatially contiguous luminance edges in the scene (Journal of Vision 13 (2013) 14), or to a relatively compressed transducer function for chromatic blur (Journal of Vision 15 (2015) 6). To test between the two explanations we conducted experiments using as stimuli both images of natural scenes as well as simple edges. First, we found that in color-and-luminance images of natural scenes more chromatic blur was needed to perceptually match a given level of blur in an isoluminant, i.e. colour-only scene. However, when the luminance layer in the scene was rotated relative to the chromatic layer, thus removing the colour-luminance edge correlations, the matched blur levels were near equal. Both results are consistent with Sharman et al.'s explanation. Second, when observers matched the blurs of luminance-only with isoluminant scenes, the matched blurs were equal, against Kingdom et al.'s prediction. Third, we measured the perceived blur in a square-wave as a function of (i) contrast (ii) number of luminance edges and (iii) the relative spatial phase between the colour and luminance edges. We found that the perceived chromatic blur was dependent on both relative phase and the number of luminance edges, or dependent on the luminance contrast if only a single edge is present. We conclude that this Hel-Or effect is largely due to masking of chromatic blur by spatially contiguous luminance edges. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Visual sensitivity for luminance and chromatic stimuli during the execution of smooth pursuit and saccadic eye movements.

    Science.gov (United States)

    Braun, Doris I; Schütz, Alexander C; Gegenfurtner, Karl R

    2017-07-01

    Visual sensitivity is dynamically modulated by eye movements. During saccadic eye movements, sensitivity is reduced selectively for low-spatial frequency luminance stimuli and largely unaffected for high-spatial frequency luminance and chromatic stimuli (Nature 371 (1994), 511-513). During smooth pursuit eye movements, sensitivity for low-spatial frequency luminance stimuli is moderately reduced while sensitivity for chromatic and high-spatial frequency luminance stimuli is even increased (Nature Neuroscience, 11 (2008), 1211-1216). Since these effects are at least partly of different polarity, we investigated the combined effects of saccades and smooth pursuit on visual sensitivity. For the time course of chromatic sensitivity, we found that detection rates increased slightly around pursuit onset. During saccades to static and moving targets, detection rates dropped briefly before the saccade and reached a minimum at saccade onset. This reduction of chromatic sensitivity was present whenever a saccade was executed and it was not modified by subsequent pursuit. We also measured contrast sensitivity for flashed high- and low-spatial frequency luminance and chromatic stimuli during saccades and pursuit. During saccades, the reduction of contrast sensitivity was strongest for low-spatial frequency luminance stimuli (about 90%). However, a significant reduction was also present for chromatic stimuli (about 58%). Chromatic sensitivity was increased during smooth pursuit (about 12%). These results suggest that the modulation of visual sensitivity during saccades and smooth pursuit is more complex than previously assumed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. High-efficiency thermal ionization sources for mass spectrometry

    International Nuclear Information System (INIS)

    Olivares, Jose A.

    1996-01-01

    A version of the thermal ionization cavity (TIC) source developed specifically for use in mass spectrometry is presented. The performance of this ion source has been characterized extensively both with the use of an isotope separator and a quadrupole mass spectrometer. A detailed description of the TIC source for mass spectrometry is given along with the performance characteristics observed

  16. A CANDIDATE FOR THE MOST LUMINOUS OB ASSOCIATION IN THE GALAXY

    International Nuclear Information System (INIS)

    Rahman, Mubdi; Matzner, Christopher; Moon, Dae-Sik

    2011-01-01

    The Milky Way harbors giant H II regions, which may be powered by star complexes more luminous than any known Galactic OB association. Being across the disk of the Galaxy, however, these brightest associations are severely extinguished and confused. We present a search for one such association toward the most luminous H II region in the recent catalog by Murray and Rahman, which, at ∼9.7 kpc, has a recombination rate of ∼7 x 10 51 s -1 . Prior searches have identified only small-scale clustering around the rim of this shell-like region, but the primary association has not previously been identified. We apply a near-infrared color selection and find an overdensity of point sources toward its southern central part. The colors and magnitudes of these excess sources are consistent with O- and early B-type stars at extinctions 0.96 K < 1.2, and they are sufficiently numerous (406 ± 102 after subtraction of field sources) to ionize the surrounding H II region, making this a candidate for the most luminous OB association in the Galaxy. We reject an alternate theory, in which the apparent excess is caused by localized extinction, as inconsistent with source demographics.

  17. Plasma instability control toward high fluence, high energy x-ray continuum source

    Science.gov (United States)

    Poole, Patrick; Kirkwood, Robert; Wilks, Scott; Blue, Brent

    2017-10-01

    X-ray source development at Omega and NIF seeks to produce powerful radiation with high conversion efficiency for material effects studies in extreme fluence environments. While current K-shell emission sources can achieve tens of kJ on NIF up to 22 keV, the conversion efficiency drops rapidly for higher Z K-alpha energies. Pulsed power devices are efficient generators of MeV bremsstrahlung x-rays but are unable to produce lower energy photons in isolation, and so a capability gap exists for high fluence x-rays in the 30 - 100 keV range. A continuum source under development utilizes instabilities like Stimulated Raman Scattering (SRS) to generate plasma waves that accelerate electrons into high-Z converter walls. Optimizing instabilities using existing knowledge on their elimination will allow sufficiently hot and high yield electron distributions to create a superior bremsstrahlung x-ray source. An Omega experiment has been performed to investigate the optimization of SRS and high energy x-rays using Au hohlraums with parylene inner lining and foam fills, producing 10× greater x-ray yield at 50 keV than conventional direct drive experiments on the facility. Experiment and simulation details on this campaign will be presented. This work was performed under the auspices of the US DoE by LLNL under Contract No. DE-AC52-07NA27344.

  18. A high current, short pulse electron source for wakefield accelerators

    International Nuclear Information System (INIS)

    Ho, Ching-Hung.

    1992-01-01

    Design studies for the generation of a high current, short pulse electron source for the Argonne Wakefield Accelerator are presented. An L-band laser photocathode rf gun cavity is designed using the computer code URMEL to maximize the electric field on the cathode surface for fixed frequency and rf input power. A new technique using a curved incoming laser wavefront to minimize the space charge effect near the photocathode is studied. A preaccelerator with large iris to minimize wakefield effects is used to boost the drive beam to a useful energy of around 20 MeV for wakefield acceleration experiments. Focusing in the photocathode gun and the preaccelerator is accomplished with solenoids. Beam dynamics simulations throughout the preaccelerator are performed using particle simulation codes TBCI-SF and PARMELA. An example providing a useful set of operation parameters for the Argonne Wakefield Accelerator is given. The effects of the sagitta of the curved beam and laser amplitude and timing jitter effects are discussed. Measurement results of low rf power level bench tests and a high power test for the gun cavity are presented and discussed

  19. Silicon nanowire based high brightness, pulsed relativistic electron source

    Directory of Open Access Journals (Sweden)

    Deep Sarkar

    2017-06-01

    Full Text Available We demonstrate that silicon nanowire arrays efficiently emit relativistic electron pulses under irradiation by a high-intensity, femtosecond, and near-infrared laser (∼1018 W/cm2, 25 fs, 800 nm. The nanowire array yields fluxes and charge per bunch that are 40 times higher than those emitted by an optically flat surface, in the energy range of 0.2–0.5 MeV. The flux and charge yields for the nanowires are observed to be directional in nature unlike that for planar silicon. Particle-in-cell simulations establish that such large emission is caused by the enhancement of the local electric fields around a nanowire, which consequently leads to an enhanced absorption of laser energy. We show that the high-intensity contrast (ratio of picosecond pedestal to femtosecond peak of the laser pulse (10−9 is crucial to this large yield. We extend the notion of surface local-field enhancement, normally invoked in low-order nonlinear optical processes like second harmonic generation, optical limiting, etc., to ultrahigh laser intensities. These electron pulses, expectedly femtosecond in duration, have potential application in imaging, material modification, ultrafast dynamics, terahertz generation, and fast ion sources.

  20. Spallation Neutron Source High Power RF Installation and Commissioning Progress

    CERN Document Server

    McCarthy, Michael P; Bradley, Joseph T; Fuja, Ray E; Gurd, Pamela; Hardek, Thomas; Kang, Yoon W; Rees, Daniel; Roybal, William; Young, Karen A

    2005-01-01

    The Spallation Neutron Source (SNS) linac will provide a 1 GeV proton beam for injection into the accumulator ring. In the normal conducting (NC) section of this linac, the Radio Frequency Quadupole (RFQ) and six drift tube linac (DTL) tanks are powered by seven 2.5 MW, 402.5 MHz klystrons and the four coupled cavity linac (CCL) cavities are powered by four 5.0 MW, 805 MHz klystrons. Eighty-one 550 kW, 805 MHz klystrons each drive a single cavity in the superconducting (SC) section of the linac. The high power radio frequency (HPRF) equipment was specified and procured by LANL and tested before delivery to ensure a smooth transition from installation to commissioning. Installation of RF equipment to support klystron operation in the 350-meter long klystron gallery started in June 2002. The final klystron was set in place in September 2004. Presently, all RF stations have been installed and high power testing has been completed. This paper reviews the progression of the installation and testing of the HPRF Sys...

  1. Solid-state high voltage modulator and its application to rf source high voltage power supplies

    International Nuclear Information System (INIS)

    Tooker, J.F.; Huynh, P.; Street, R.W.

    2009-01-01

    A solid-state high voltage modulator is described in which series-connected insulated-gate bipolar transistors (IGBTs) are switched at a fixed frequency by a pulse width modulation (PWM) regulator, that adjusts the pulse width to control the voltage out of an inductor-capacitor filter network. General Atomics proposed the HV power supply (HVPS) topology of multiple IGBT modulators connected to a common HVdc source for the large number of 1 MW klystrons in the linear accelerator of the Accelerator Production of Tritium project. The switching of 24 IGBTs to obtain 20 kVdc at 20 A for short pulses was successfully demonstrated. This effort was incorporated into the design of a -70 kV, 80 A, IGBT modulator, and in a short-pulse test 12 IGBTs regulated -5 kV at 50 A under PWM control. These two tests confirm the practicality of solid-state IGBT modulators to regulate high voltage at reasonable currents. Tokamaks such as ITER require large rf heating and current drive systems with multiple rf sources. A HVPS topology is presented that readily adapts to the three rf heating systems on ITER. To take advantage of the known economy of scale for power conversion equipment, a single HVdc source feeds multiple rf sources. The large power conversion equipment, which is located outside, converts the incoming utility line voltage directly to the HVdc needed for the class of rf sources connected to it, to further reduce cost. The HVdc feeds a set of IGBT modulators, one for each rf source, to independently control the voltage applied to each source, maximizing operational flexibility. Only the modulators are indoors, close to the rf sources, minimizing the use of costly near-tokamak floor space.

  2. H- Ion Sources for High Intensity Proton Drivers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dudnikov, Vadim [Muons, Inc., Batavia, IL (United States)

    2015-02-20

    Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

  3. Dietary Sources of High Sodium Intake in Turkey: SALTURK II

    Directory of Open Access Journals (Sweden)

    Yunus Erdem

    2017-08-01

    Full Text Available Previous research has shown daily salt intakes in Turkey to be far above the recommended limits. Knowing the sources of dietary salt could form a basis for preventive strategies aimed towards salt reduction. This study aimed to investigate dietary sources of salt in Turkey. A sub-group (n = 657 was selected from the PatenT2 study population, which represented the urban and rural areas of 4 major cities (Ankara, Istanbul, Izmir, and Konya. A questionnaire inquiring about sociodemographic characteristics, medical histories, detailed histories of diet, and salt consumption was completed. Participants were asked to collect a 24-h urine sample and to record their food intake (dietary recall on the same day. Of 925 participants selected, 657 (71% provided accurate 24-h urine collections, based on creatinine excretion data. The mean daily 24-h urinary sodium excretion was 252.0 ± 92.2 mmol/day, equal to daily salt intake of 14.8 ± 5.4 g. Of the 657 participants with accurate 24-h urine collections, 464 (70% provided fully completed dietary recalls. Among these 464 participants, there was a significant difference between the 24-h urinary sodium excretion-based salt intake estimation (14.5 ± 5.1 g/day and the dietary recall-based salt intake estimation (12.0 ± 7.0 g/day (p < 0.001. On the other hand, a positive correlation was obtained between the dietary recall-based daily salt intake and 24-h urinary sodium excretion-based daily salt intake (r = 0.277, p < 0.001. Bread was the main source of salt (34% followed by salt added during cooking and preparing food before serving (30%, salt from various processed foods (21%, and salt added at the table during food consumption (11%. Conclusively, this study confirmed a very high salt intake of the adult population in four major cities in Turkey. The present findings support the emerging salt reduction strategy in Turkey by promoting lower salt content in baked bread, and less salt use in habitual food

  4. Covariation of Color and Luminance Facilitate Object Individuation in Infancy

    Science.gov (United States)

    Woods, Rebecca J.; Wilcox, Teresa

    2010-01-01

    The ability to individuate objects is one of our most fundamental cognitive capacities. Recent research has revealed that when objects vary in color or luminance alone, infants fail to individuate those objects until 11.5 months. However, color and luminance frequently covary in the natural environment, thus providing a more salient and reliable…

  5. Luminous flux and colour maintenance investigation of integrated LED lamps

    DEFF Research Database (Denmark)

    Corell, Dennis Dan; Thorseth, Anders; Dam-Hansen, Carsten

    2014-01-01

    This article will present an investigation of the luminous flux and colour maintenance of white LED based retrofit lamps. The study includes 23 different types of integrated LED lamps, covering 18 directional and 5 non-directional. Luminous flux and colour data for operation up to 20000 h has been...

  6. The First Hyper-Luminous Infrared Galaxy Discovered by WISE

    Science.gov (United States)

    Eisenhardt, Peter R.; Wu, Jingwen; Tsai, Chao-Wei; Assef, Roberto; Benford, Dominic; Blain, Andrew; Bridge, Carrie; Condon, J. J.; Cushing, Michael C.; Cutri, Roc; hide

    2012-01-01

    We report the discovery by the Wide-field Infrared Survey Explorer of the z = 2.452 source WISEJ181417.29+341224.9, the first hyperluminous source found in the WISE survey. WISE 1814+3412 is also the prototype for an all-sky sample of approximately 1000 extremely luminous "W1W2-dropouts" (sources faint or undetected by WISE at 3.4 and 4.6 micrometers and well detected at 12 or 22 micrometers). The WISE data and a 350 micrometers detection give a minimum bolometric luminosity of 3.7 x 10(exp 13) solar luminosity, with approximately 10(exp 14) solar luminosity plausible. Followup images reveal four nearby sources: a QSO and two Lyman Break Galaxies (LBGs) at z = 2.45, and an M dwarf star. The brighter LBG dominates the bolometric emission. Gravitational lensing is unlikely given the source locations and their different spectra and colors. The dominant LBG spectrum indicates a star formation rate approximately 300 solar mass yr(exp -1), accounting for less than or equal to 10 percent of the bolometric luminosity. Strong 22 micrometer emission relative to 350 micrometer implies that warm dust contributes significantly to the luminosity, while cooler dust normally associated with starbursts is constrained by an upper limit at 1.1 mm. Radio emission is approximately 10? above the far-infrared/radio correlation, indicating an active galactic nucleus is present. An obscured AGN combined with starburst and evolved stellar components can account for the observations. If the black hole mass follows the local MBH-bulge mass relation, the implied Eddington ratio is approximately greater than 4. WISE 1814+3412 may be a heavily obscured object where the peak AGN activity occurred prior to the peak era of star formation.

  7. High-current pulsed ion source for metallic ions

    International Nuclear Information System (INIS)

    Gavin, B.; Abbott, S.; MacGill, R.; Sorensen, R.; Staples, J.; Thatcher, R.

    1981-03-01

    A new sputter-ion PIG source and magnet system, optimized for intermediate charge states, q/A of 0.02 to 0.03, is described. This source will be used with the new Wideroe-based injector for the SuperHILAC. Pulsed electrical currents of several emA of heavy metal ions have been produced in a normalized emittance area of .05π cm-mr. The source system is comprised of two electrically separate anode chambers, one in operation and one spare, which can be selected by remote control. The entire source head is small and quickly removable

  8. SLC polarized beam source ultra-high-vacuum design

    International Nuclear Information System (INIS)

    Lavine, T.L.; Clendenin, J.E.; Garwin, E.L.; Hoyt, E.W.; Hoyt, M.W.; Miller, R.H.; Nuttall, J.A.; Schultz, D.C.; Wright, D.

    1991-05-01

    This paper describes the design of the ultra-high vacuum system for the beam-line from the 160-kV polarized electron gun to the linac injector in the Stanford Linear Collider (SLC). The polarized electron source is a GaAs photocathode, requiring 10 -11 -Torr-range pressure for adequate quantum efficiency and longevity. The photo-cathode is illuminated by 3-nsec-long laser pulses. Photo-cathode maintenance and improvements require occasional substitution of guns with rapid restoration of UHV conditions. Differential pumping is crucial since the pressure in the injector is more than 10 times greater than the photocathode can tolerate, and since electron-stimulated gas desorption from beam loss in excess of 0.1% of the 20-nC pulses may poison the photocathode. Our design for the transport line contains a differential pumping region isolated by a pair of valves. Exchange of guns requires venting only this isolated region which can be restored to UHV rapidly by baking. The differential pumping is performed by non-evaporable getters (NEGs) and an ion pump. 3 refs., 3 figs

  9. High power pulsed neutron source for electronuclear installation

    Energy Technology Data Exchange (ETDEWEB)

    Korenev, S.A.; Puzynin, I.V.; Samoilov, V.N.; Sissakian, A.N. [Joint Inst. for Nuclear Research, Dubna (Russian Federation)

    1997-09-01

    The pulsed neutron source based on the reaction T(d,n)He is described in this report. The source consists of pulsed a pulsed Arkad`ev-Marx generator and a vacuum diode with explosive ion emission. 9 refs., 3 figs.

  10. Densities, cellulases, alginate and pectin lyases of luminous and other heterotrophic bacteria associated with marine algae

    Digital Repository Service at National Institute of Oceanography (India)

    Ramaiah, N.; Chandramohan, D.

    Epiphytic luminous and non-luminous bacteria were determined quantitatively for eight intertidal algal species from rocky beaches of Goa and Lakshadweep coral reef lagoon. Luminous bacteria were present on all eight algal species and contributed 2...

  11. Management Optimization of the Luminous Flux Regulation of a Lighting System in Road Tunnels. A First Approach to the Exertion of Predictive Control Systems

    Directory of Open Access Journals (Sweden)

    Ferdinando Salata

    2016-10-01

    Full Text Available Lighting very long road tunnels implies a high consumption of electrical energy since it requires a proper illumination during the whole day. In particular, in the daytime, the illuminance levels right at the tunnel entrance threshold and exit zones must be higher than those characterizing the inside of the tunnel; in this way, the eye of the driver is able to adapt and be safe while passing from a high natural illumination of the outside to the lighting conditions characterizing the inside of the tunnel. However this causes a high energy demand. Therefore, this case study investigates whether it is possible to minimize the energy demand through the exertion of an automatic new control system regulating the luminous fluxes of artificial sources (guaranteeing the parameters set by the regulation with respect to the variation of the natural light characterizing the outside. The innovative control systems must be characterized by high reliability levels in order to guarantee conditions which are not dangerous to the driver if an outage occurs and minimize their maintenance costs. To carry out this type of study, the software DIALux was used to simulate a tunnel with a dimming system (with lamps characterized by a high luminous efficiency regulated by a pre-programmed logic control system (with high Mean Time Between Failure (MTBF values. The savings obtained enabled the amortization of the solution here suggested in a time interval that makes it an advantageous choice economically speaking.

  12. Physical mechanisms leading to high currents of highly charged ions in laser-driven ion sources

    International Nuclear Information System (INIS)

    Haseroth, Helmut; Hora, Heinrich; Regensburg Inst. of Tech.

    1996-01-01

    Heavy ion sources for the big accelerators, for example, the LHC, require considerably more ions per pulse during a short time than the best developed classical ion source, the electron cyclotron resonance (ECR) provides; thus an alternative ion source is needed. This can be expected from laser-produced plasmas, where dramatically new types of ion generation have been observed. Experiments with rather modest lasers have confirmed operation with one million pulses of 1 Hz, and 10 11 C 4+ ions per pulse reached 2 GeV/u in the Dubna synchrotron. We review here the complexities of laser-plasma interactions to underline the unique and extraordinary possibilities that the laser ion source offers. The complexities are elaborated with respect to keV and MeV ion generation, nonlinear (ponderomotive) forces, self-focusing, resonances and ''hot'' electrons, parametric instabilities, double-layer effects, and the few ps stochastic pulsation (stuttering). Recent experiments with the laser ion source have been analyzed to distinguish between the ps and ns interaction, and it was discovered that one mechanism of highly charged ion generation is the electron impact ionization (EII) mechanism, similar to the ECR, but with so much higher plasma densities that the required very large number of ions per pulse are produced. (author)

  13. Physical mechanisms leading to high currents of highly charged ions in laser-driven ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Haseroth, Helmut [European Organization for Nuclear Research, Geneva (Switzerland); Hora, Heinrich [New South Wales Univ., Kensington, NSW (Australia)]|[Regensburg Inst. of Tech. (Germany). Anwenderzentrum

    1996-12-31

    Heavy ion sources for the big accelerators, for example, the LHC, require considerably more ions per pulse during a short time than the best developed classical ion source, the electron cyclotron resonance (ECR) provides; thus an alternative ion source is needed. This can be expected from laser-produced plasmas, where dramatically new types of ion generation have been observed. Experiments with rather modest lasers have confirmed operation with one million pulses of 1 Hz, and 10{sup 11} C{sup 4+} ions per pulse reached 2 GeV/u in the Dubna synchrotron. We review here the complexities of laser-plasma interactions to underline the unique and extraordinary possibilities that the laser ion source offers. The complexities are elaborated with respect to keV and MeV ion generation, nonlinear (ponderomotive) forces, self-focusing, resonances and ``hot`` electrons, parametric instabilities, double-layer effects, and the few ps stochastic pulsation (stuttering). Recent experiments with the laser ion source have been analyzed to distinguish between the ps and ns interaction, and it was discovered that one mechanism of highly charged ion generation is the electron impact ionization (EII) mechanism, similar to the ECR, but with so much higher plasma densities that the required very large number of ions per pulse are produced. (author).

  14. Virtual ultrasound sources in high-resolution ultrasound imaging

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Jensen, Jørgen Arendt

    2002-01-01

    beamforming procedure for 3D ultrasound imaging. The position of the virtual source, and the created waveform are investigated with simulation, and with pulse-echo measurements. There is good agreement between the estimated wavefront and the theoretically tted one. Several examples of the use of virtual...... source elements are considered. Using SAF on data acquired for a conventional linear array imaging improves the penetration depth for the particular imaging situation from 80 to 110 mm. The independent use of virtual source elements in the elevation plane decreases the respective size of the point spread...

  15. High intensity negative proton beams from a SNICS ion source

    International Nuclear Information System (INIS)

    Evans, C.R.; Hollander, M.G.

    1991-01-01

    For the past year we have been involved in a project to develop an intense (> 100μA) negative proton beam from a SNICS (Source of Negative Ions by Cesium Sputtering) ion source. This report will cover how we accomplished and exceeded this goal by more than 40%. Included in these observations will be the following: A description of an effective method for making titanium hydride cathodes. How to overcome the limitations of the titanium hydride cathode. The modification of the SNICS source to improve output; including the installation of the conical ionizer and the gas cathode. A discussion of problems including: poisoning the proton beam with oxygen, alternative gas cathode materials, the clogging of the gas inlet, long burn-in times, and limited cathode life times. Finally, how to optimize source performance when using a gas cathode, and what is the mechanism by which a gas cathode operates; facts, fantasies, or myth

  16. Stability of high-brilliance synchrotron radiation sources

    International Nuclear Information System (INIS)

    Chattopadhyay, S.

    1989-12-01

    This paper discusses the following topics: characteristics of synchrotron radiation sources; stability of the orbits; orbit control; nonlinear dynamic stability; and coherent stability and control. 1 ref., 5 figs., 1 tab

  17. High Fidelity Tool for Noise Source Identification, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Thorough understanding of airframe and propulsion aerodynamic noise sources and the subsequent acoustic propagation to the farfield is necessary to the design and...

  18. A high efficiency thermal ionization source adapted to mass spectrometers

    International Nuclear Information System (INIS)

    Chamberlin, E.P.; Olivares, J.A.

    1996-01-01

    A tungsten crucible thermal ionization source mounted on a quadrupole mass spectrometer is described. The crucible is a disposable rod with a fine hole bored in one end; it is heated by electron bombardment. The schematic design of the assembly, including water cooling, is described and depicted. Historically, the design is derived from that of ion sources used on ion separators at Los Alamos and Dubna, but the crucible is made smaller and simplified. 10 refs., 4 figs

  19. High Power Modulator/regulators for neutral beam sources

    International Nuclear Information System (INIS)

    Lawson, J.Q.; Deitz, A.

    1975-01-01

    PPPL has recently completed two new Modulator/Regulators for neutral injection sources used on the ATC machine and is constructing four new ones for use with sources on the PLT machine. The ATC modulator uses the well proven 4CX35,000C tetrode as the main switch tube, while the PLT modulators will be using the new but significantly higher powered X-2170 tetrodes. Some interesting circuit and manufacturing techniques are discussed

  20. Calibrating photometric redshifts of luminous red galaxies

    International Nuclear Information System (INIS)

    Padmanabhan, Nikhil; Budavari, Tamas; Schlegel, David J.; Bridges, Terry; Brinkmann, Jonathan

    2005-01-01

    We discuss the construction of a photometric redshift catalogue of luminous red galaxies (LRGs) from the Sloan Digital Sky Survey (SDSS), emphasizing the principal steps necessary for constructing such a catalogue: (i) photometrically selecting the sample, (ii) measuring photometric redshifts and their error distributions, and (iii) estimating the true redshift distribution. We compare two photometric redshift algorithms for these data and find that they give comparable results. Calibrating against the SDSS and SDSS–2dF (Two Degree Field) spectroscopic surveys, we find that the photometric redshift accuracy is σ~ 0.03 for redshifts less than 0.55 and worsens at higher redshift (~ 0.06 for z < 0.7). These errors are caused by photometric scatter, as well as systematic errors in the templates, filter curves and photometric zero-points. We also parametrize the photometric redshift error distribution with a sum of Gaussians and use this model to deconvolve the errors from the measured photometric redshift distribution to estimate the true redshift distribution. We pay special attention to the stability of this deconvolution, regularizing the method with a prior on the smoothness of the true redshift distribution. The methods that we develop are applicable to general photometric redshift surveys.

  1. Informational primacy of visual dimensions: specialized roles for luminance and chromaticity in figure-ground perception.

    Science.gov (United States)

    Yamagishi, N; Melara, R D

    2001-07-01

    Three experiments were conducted to examine the distinct contributions of two visual dimensions to figure-ground segregation. In each experiment, pattern identification was assessed by asking observers to judge whether a near-threshold test pattern was the same or different in shape to a high-contrast comparison pattern. A test pattern could differ from its background along one dimension, either luminance (luminance tasks) or chromaticity (chromaticity tasks). In each task, performance in a baseline condition, in which the test pattern was intact, was compared with performance in each of several degradation conditions, in which either the contour or the surface of the figure was degraded, using either partial occlusion (Experiment 1) or ramping (Experiments 2 and 3) of figure-ground differences. In each experiment, performance in luminance tasks was worst when the contour was degraded, whereas performance in chromaticity tasks was worst when the surface was degraded. This interaction was found even when spatial frequencies were fixed across test patterns by low-pass filtering. The results are consistent with a late (postfiltering) dual-mechanism system that processes luminance information to extract boundary representations and chromaticity information to extract surface representations.

  2. Cloning and characterization of luciferase from a Fijian luminous click beetle.

    Science.gov (United States)

    Mitani, Yasuo; Futahashi, Ryo; Niwa, Kazuki; Ohba, Nobuyoshi; Ohmiya, Yoshihiro

    2013-01-01

    Luminous click beetle is distributed almost exclusively in Central and South America with a single genus in Melanesia. Among these click beetles, the description of Melanesian species has been fragmentary, and its luciferase gene and phylogenetic relation to other click beetles still remain uncertain. We collected a living luminous click beetle, Photophorus jansonii in Fiji. It emits green-yellow light from two spots on the pronotum and has no ventral luminous organ. Here, we cloned a luciferase gene from this insect by RT-PCR. The deduced amino acid sequence showed high identity of ~85% to the luciferases derived from other click beetle species. The luciferase of the Fijian click beetle was produced as a recombinant protein to characterize its biochemical properties. The Km for D-luciferin and ATP were 173 and 270 μm, respectively. The luciferase was pH-insensitive and the spectrum measured at pH 8.0 showed a peak at 559 nm, which was in the range of green-yellow light as seen in the luminous spot of the living Fijian click beetle. The Fijian click beetle luciferase was assigned to the Elateridae clade by a phylogenetic analysis, but it made a clearly different branch from Pyrophorus group examined in this study. © 2013 The American Society of Photobiology.

  3. The effect of chromatic and luminance information on reaction times.

    Science.gov (United States)

    O'Donell, Beatriz M; Barraza, Jose F; Colombo, Elisa M

    2010-07-01

    We present a series of experiments exploring the effect of chromaticity on reaction time (RT) for a variety of stimulus conditions, including chromatic and luminance contrast, luminance, and size. The chromaticity of these stimuli was varied along a series of vectors in color space that included the two chromatic-opponent-cone axes, a red-green (L-M) axis and a blue-yellow [S - (L + M)] axis, and intermediate noncardinal orientations, as well as the luminance axis (L + M). For Weber luminance contrasts above 10-20%, RTs tend to the same asymptote, irrespective of chromatic direction. At lower luminance contrast, the addition of chromatic information shortens the RT. RTs are strongly influenced by stimulus size when the chromatic stimulus is modulated along the [S - (L + M)] pathway and by stimulus size and adaptation luminance for the (L-M) pathway. RTs are independent of stimulus size for stimuli larger than 0.5 deg. Data are modeled with a modified version of Pieron's formula with an exponent close to 2, in which the stimulus intensity term is replaced by a factor that considers the relative effects of chromatic and achromatic information, as indexed by the RMS (square-root of the cone contrast) value at isoluminance and the Weber luminance contrast, respectively. The parameters of the model reveal how RT is linked to stimulus size, chromatic channels, and adaptation luminance and how they can be interpreted in terms of two chromatic mechanisms. This equation predicts that, for isoluminance, RTs for a stimulus lying on the S-cone pathway are higher than those for a stimulus lying on the L-M-cone pathway, for a given RMS cone contrast. The equation also predicts an asymptotic trend to the RT for an achromatic stimulus when the luminance contrast is sufficiently large.

  4. The study towards high intensity high charge state laser ion sources.

    Science.gov (United States)

    Zhao, H Y; Jin, Q Y; Sha, S; Zhang, J J; Li, Z M; Liu, W; Sun, L T; Zhang, X Z; Zhao, H W

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  5. Thulium heat source for high-endurance and high-energy density power systems

    International Nuclear Information System (INIS)

    Walter, C.E.; Kammeraad, J.E.; Van Konynenburg, R.; VanSant, J.H.

    1991-05-01

    We are studying the performance characteristics of radioisotope heat source designs for high-endurance and high-energy-density power systems that use thulium-170. Heat sources in the power range of 5--50 kW th coupled with a power conversion efficiency of ∼30%, can easily satisfy current missions for autonomous underwater vehicles. New naval missions will be possible because thulium isotope power systems have a factor of one-to-two hundred higher endurance and energy density than chemical and electrochemical systems. Thulium-170 also has several other attractive features, including the fact that it decays to stable ytterbium-170 with a half-life of four months. For terrestrial applications, refueling on that time scale should be acceptable in view of the advantage of its benign decay. The heat source designs we are studying account for the requirements of isotope production, shielding, and integration with power conversion components. These requirements are driven by environmental and safety considerations. Thulium is present in the form of thin refractory thulia disks that allow power conversion at high peak temperature. We give estimates of power system state points, performance, mass, and volume characteristics. Monte Carlo radiation analysis provides a detailed assessment of shield requirements and heat transfer under normal and distressed conditions is also considered. 11 refs., 7 figs., 4 tabs

  6. Prototype high current, high duty factor negative hydrogen ion source for LAMPF

    International Nuclear Information System (INIS)

    Lawrence, G.P.; Hayward, T.D.; Jackson, J.A.

    1975-01-01

    Present plans for the high current proton storage ring at LAMPF incorporate charge changing (stripping) injection of H - ions in all modes of operation. Achievable stored current levels in this device will be strongly dependent on the maximum H - beam intensity which can be accelerated by the linac, consistent with acceptable beam spill. This requirement has stimulated a program to develop an H - ion source capable of providing a suitably high peak current (up to 25 mA) at high duty factor (up to 12 percent), with a normalized x,x' or y,y' emittance acceptable to the accelerating system. There are presently two main approaches which could lead to H - ion sources providing this kind of performance. These are (a) the charge exchange method, in which an intense proton beam is fractionally converted to H - beam in a suitable charge adding medium, and (b) the direct extraction method, in which H - ions are obtained by a surface emission process associated with a gas discharge plasma. While both approaches may eventually find optimum application in different situations, it is not obvious, at present, which scheme will turn out to be the most satisfactory for LAMPF. A prototype charge exchange H - ion source has been constructed as a first step in the development program and is presently being evaluated. Work on surface emission direct extraction techniques is in the planning stages. (U.S.)

  7. High brilliance multicusp ion source for hydrogen microscopy at SNAKE

    Energy Technology Data Exchange (ETDEWEB)

    Moser, M., E-mail: marcus.moser@unibw.de [Universitaet der Bundeswehr Muenchen, Institut fuer Angewandte Physik und Messtechnik, LRT2, Department fuer Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany); Reichart, P. [Universitaet der Bundeswehr Muenchen, Institut fuer Angewandte Physik und Messtechnik, LRT2, Department fuer Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany); Carli, W. [Maier-Leibniz-Laboraturium der LMU und TU Muenchen, 85478 Garching (Germany); Greubel, C.; Peeper, K. [Universitaet der Bundeswehr Muenchen, Institut fuer Angewandte Physik und Messtechnik, LRT2, Department fuer Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany); Hartung, P. [Maier-Leibniz-Laboraturium der LMU und TU Muenchen, 85478 Garching (Germany); Dollinger, G. [Universitaet der Bundeswehr Muenchen, Institut fuer Angewandte Physik und Messtechnik, LRT2, Department fuer Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany)

    2012-02-15

    In order to improve the lateral resolution of the 3D hydrogen microscopy by proton-proton scattering at the Munich microprobe SNAKE, we have installed a new multicusp ion source for negative hydrogen ions manufactured by HVEE at the Munich 14 MV tandem accelerator that boosts the proton beam brilliance with the potential to reduce the beam diameter at the focal plane of SNAKE. We measured a beam brilliance B = 27 A m{sup -2} rad{sup -2} eV{sup -1} directly behind the ion source that is at the space charge limit for conventional ion sources. After preacceleration to in total 180 keV beam energy we measure a slightly reduced beam brilliance of B = 10 {mu}A mm{sup -2} mrad{sup -2} MeV{sup -1}. For injection into the tandem accelerator, the extracted H{sup -}-current of the multicusp source of 1 mA is reduced to about 10 {mu}A because of radiation safety regulations and heating problems at the object slits of SNAKE. Due to beam oscillations and influences of the terminal stripper of the tandem we measured a reduced beam brilliance of 0.8 {mu}A mm{sup -2} mrad{sup -2} MeV{sup -1} in front of SNAKE at 25 MeV but still being nearly 10 times larger than measured with any other ion source.

  8. Hot spots effect on infrared spectral luminance emitted by carbon under plasma particles impact

    International Nuclear Information System (INIS)

    Delchambre, E.; Reichle, R.; Mitteau, R.; Missirlian, M.; Gobin, R.

    2004-01-01

    During the last Tore Supra campaigns, an anomalous deformation in the near infrared spectrum of radiation has been observed on neutralizer underneath the Toroidal Pumped Limiter (TPL) on which we observed the growth of carbon layer. The consequence is the difficulty to asses the surface temperature of the components and the power loaded. Laboratory experiment has been performed, using an Electron Cyclotron Resonance (ECR) ions source, to reproduce, characterize and explain this phenomenon. The luminance emitted by Carbon Fibre Composite (CFC) and pyrolytic graphite, have been observed under 95 keV of H+ bombardments. The amplitude of the deformation was found to depend on the type of material used and the power density of the incident power loaded. This paper presents the possible hot spots explanation. The experimental luminance deformation is reproduced and these results are validated using a thermal model of dust in radiate equilibrium. (authors)

  9. Symbiotic association of Photobacterium fischeri with the marine luminous fish Monocentris japonica; a model of symbiosis based on bacterial studies.

    Science.gov (United States)

    Ruby, E G; Nealson, K H

    1976-12-01

    Isolation of bacteria from the luminous organ of the fish Monocentris japonica has revealed that the organ contains a pure culture of luminous bacteria. For the four fish examined, all contained Photobacterium fischeri as their luminous bacterial symbiont. This is the first time that P. fischeri has been identified in a symbiotic association. A representative isolate (MJl) of the light organ population was selected for in vivo studies of its luminous system. Several physiological features suggest adaptation for symbiotic existence. First, MJl has been shown to produce and respond to an inducer of luciferase that could accumulate in the light organ. Secondly, the specific activity of light production was seen to be maximal under low, growth-limiting concentrations of oxygen. Thirdly, unlike another luminous species (Beneckea harveyi), synthesis of the light production system of these bacteria is not catabolite repressed by glucose--a possible source of nutrition in the light organ. Fourthly, when grown aerobically on glucose these bacteria excrete pyruvic acid into the medium. This production of pyruvate is a major process, accounting for 30-40% of the glucose utilized and may serve as a form of regulatory and nutritional communication with the host.

  10. Some high-current ion sources for materials modification

    International Nuclear Information System (INIS)

    Taylor, T.

    1989-01-01

    Ion sources for materials modification have evolved through three distinct generations. The first generation was adopted from research accelerators. These cold-cathode plasma-discharge devices generate beam currents of less than 100 μA. The hot-cathode plasma-discharge ion sources, originally developed for isotope separation, comprise the second generation. They produce between 100 μA and 10 mA of beam current. The third generation ion sources give beam currents in excess of 10 mA. This technology, transferred from industrial accelerators, has already made SIMOX (Separation by IMplanted OXygen) into a commercially viable semiconductor process and promises to do the same for ion implantation of metals and insulators. The author focuses on the third generation technology that will play a key role in the future of ion implantation. 10 refs.; 5 figs.; 2 tabs

  11. Application of optical emission spectroscopy to high current proton sources

    International Nuclear Information System (INIS)

    Castro, G; Mazzaglia, M; Nicolosi, D; Mascali, D; Reitano, R; Celona, L; Leonardi, O; Leone, F; Naselli, E; Neri, L; Torrisi, G; Gammino, S; Zaniol, B

    2017-01-01

    Optical Emission Spectroscopy (OES) represents a very reliable technique to carry out non-invasive measurements of plasma density and plasma temperature in the range of tens of eV. With respect to other diagnostics, it also can characterize the different populations of neutrals and ionized particles constituting the plasma. At INFN-LNS, OES techniques have been developed and applied to characterize the plasma generated by the Flexible Plasma Trap, an ion source used as 'testbench' of the proton source built for European Spallation Source. This work presents the characterization of the parameters of a hydrogen plasma in different conditions of neutral pressure, microwave power and magnetic field profile, along with perspectives for further upgrades of the OES diagnostics system. (paper)

  12. The WISSH quasars project. II. Giant star nurseries in hyper-luminous quasars

    Science.gov (United States)

    Duras, F.; Bongiorno, A.; Piconcelli, E.; Bianchi, S.; Pappalardo, C.; Valiante, R.; Bischetti, M.; Feruglio, C.; Martocchia, S.; Schneider, R.; Vietri, G.; Vignali, C.; Zappacosta, L.; La Franca, F.; Fiore, F.

    2017-08-01

    Context. Studying the coupling between the energy output produced by the central quasar and the host galaxy is fundamental to fully understand galaxy evolution. Quasar feedback is indeed supposed to dramatically affect the galaxy properties by depositing large amounts of energy and momentum into the interstellar medium (ISM). Aims: In order to gain further insights on this process, we study the spectral energy distributions (SEDs) of sources at the brightest end of the quasar luminosity function, for which the feedback mechanism is assumed to be at its maximum, given their high efficiency in driving powerful outflows. Methods: We modelled the rest-frame UV-to-far-IR SEDs of 16 WISE-SDSS Selected Hyper-luminous (WISSH) quasars at 1.8 code to account for the contribution of the quasar-related emission to the far-IR fluxes. Results: Most SEDs are well described by a standard combination of accretion disc plus torus and cold dust emission. However, about 30% of SEDs require an additional emission component in the near-IR, with temperatures peaking at 750 K, which indicates that a hotter dust component is present in these powerful quasars. We measure extreme values of both AGN bolometric luminosity (LBOL > 1047 erg/s) and star formation rate (up to 2000 M⊙/yr) based on the quasar-corrected, IR luminosity of the host galaxy. A new relation between quasar and star formation luminosity is derived (LSF ∝ L0.73QSO) by combining several Herschel-detected quasar samples from z 0 to 4. WISSH quasars have masses ( 108M⊙) and temperatures ( 50 K) of cold dust in agreement with those found for other high-z IR luminous quasars. Conclusions: Thanks to their extreme nuclear and star formation luminosities, the WISSH quasars are ideal targets to shed light on the feedback mechanism and its effect on the evolution of their host galaxies, as well as on the merger-induced scenario that is commonly assumed to explain these exceptional luminosities. Future observations will be

  13. FAR-INFRARED PROPERTIES OF SPITZER-SELECTED LUMINOUS STARBURSTS

    International Nuclear Information System (INIS)

    Kovacs, A.; Omont, A.; Fiolet, N.; Beelen, A.; Dole, H.; Lagache, G.; Lonsdale, C.; Polletta, M.; Greve, T. R.; Borys, C.; Dowell, C. D.; Bell, T. A.; Cox, P.; De Breuck, C.; Farrah, D.; Menten, K. M.; Owen, F.

    2010-01-01

    We present SHARC-2 350 μm data on 20 luminous z ∼ 2 starbursts with S 1.2 m m > 2 mJy from the Spitzer-selected samples of Lonsdale et al. and Fiolet et al. All the sources were detected, with S 350 μ m > 25 mJy for 18 of them. With the data, we determine precise dust temperatures and luminosities for these galaxies using both single-temperature fits and models with power-law mass-temperature distributions. We derive appropriate formulae to use when optical depths are non-negligible. Our models provide an excellent fit to the 6 μm-2 mm measurements of local starbursts. We find characteristic single-component temperatures T 1 ≅ 35.5 ± 2.2 K and integrated infrared (IR) luminosities around 10 12.9±0.1 L sun for the SWIRE-selected sources. Molecular gas masses are estimated at ≅4 x 10 10 M sun , assuming κ 850 μ m = 0.15 m 2 kg -1 and a submillimeter-selected galaxy (SMG)-like gas-to-dust mass ratio. The best-fit models imply ∼>2 kpc emission scales. We also note a tight correlation between rest-frame 1.4 GHz radio and IR luminosities confirming star formation as the predominant power source. The far-IR properties of our sample are indistinguishable from the purely submillimeter-selected populations from current surveys. We therefore conclude that our original selection criteria, based on mid-IR colors and 24 μm flux densities, provides an effective means for the study of SMGs at z ∼ 1.5-2.5.

  14. Mass analyzer ``MASHA'' high temperature target and plasma ion source

    Science.gov (United States)

    Semchenkov, A. G.; Rassadov, D. N.; Bekhterev, V. V.; Bystrov, V. A.; Chizov, A. Yu.; Dmitriev, S. N.; Efremov, A. A.; Guljaev, A. V.; Kozulin, E. M.; Oganessian, Yu. Ts.; Starodub, G. Ya.; Voskresensky, V. M.; Bogomolov, S. L.; Paschenko, S. V.; Zelenak, A.; Tikhonov, V. I.

    2004-05-01

    A new separator and mass analyzer of super heavy atoms (MASHA) has been created at the FLNR JINR Dubna to separate and measure masses of nuclei and molecules with precision better than 10-3. First experiments with the FEBIAD plasma ion source have been done and give an efficiency of ionization of up to 20% for Kr with a low flow test leak (6 particle μA). We suppose a magnetic field optimization, using the additional electrode (einzel lens type) in the extracting system, and an improving of the vacuum conditions in order to increase the ion source efficiency.

  15. Mass analyzer 'MASHA' high temperature target and plasma ion source

    International Nuclear Information System (INIS)

    Semchenkov, A.G.; Rassadov, D.N.; Bekhterev, V.V.; Bystrov, V.A.; Chizov, A.Yu.; Dmitriev, S.N.; Efremov, A.A.; Guljaev, A.V.; Kozulin, E.M.; Oganessian, Yu.Ts.; Starodub, G.Ya.; Voskresensky, V.M.; Bogomolov, S.L.; Paschenko, S.V.; Zelenak, A.; Tikhonov, V.I.

    2004-01-01

    A new separator and mass analyzer of super heavy atoms (MASHA) has been created at the FLNR JINR Dubna to separate and measure masses of nuclei and molecules with precision better than 10 -3 . First experiments with the FEBIAD plasma ion source have been done and give an efficiency of ionization of up to 20% for Kr with a low flow test leak (6 particle μA). We suppose a magnetic field optimization, using the additional electrode (einzel lens type) in the extracting system, and an improving of the vacuum conditions in order to increase the ion source efficiency

  16. Characteristics of a high current ion source operated with lithium

    International Nuclear Information System (INIS)

    Bay, H.L.; Dullni, E.; Leismann, P.

    1986-05-01

    A low pressure arc ion source has been tested for operation with lithium. Currents up to 120 mA could be extracted through a multiple aperture extraction system at energies of 30 keV. The ion beam was neutralized up to 70% in a charge exchange cell filled with lithium vapour. The beam divergence ranged from 20 to 25 mrad full angle deduced from the spatial distribution of the collision induced Li I resonance line. Current densities from 2 to 3 mA/m 2 at a distance of 1.9 m from the source were measured either by laser induced fluorescence or with a Faraday cup. (orig.)

  17. Electrode cooling for long pulse high current ion sources

    International Nuclear Information System (INIS)

    McKenzie-Wilson, R.B.

    1979-01-01

    The need for cooling of electrode surface in ion sources for neutral beam line applications is summarized. The properties of possible cooling fluids are discussed and the decision to use water as a cooling fluid of choice is explained. The influence of source geometry on the design of a cooling canal is examined and two possible designs are presented. The need for model testing and the results of the tests on a model cathode are also discussed. Some remarks are also made on a method of predicting burnout failure of a cooled electrode

  18. Bulk Comptonization: new hints from the luminous blazar 4C+25.05

    Science.gov (United States)

    Kammoun, E. S.; Nardini, E.; Risaliti, G.; Ghisellini, G.; Behar, E.; Celotti, A.

    2018-01-01

    Blazars are often characterized by a spectral break at soft X-rays, whose origin is still debated. While most sources show a flattening, some exhibit a blackbody-like soft excess with temperatures of the order of ∼0.1 keV, similar to low-luminosity, non-jetted Seyferts. Here, we present the analysis of the simultaneous XMM-Newton and NuSTAR observations of the luminous flat-spectrum radio quasar 4C+25.05 (z = 2.368). The observed 0.3-30 keV spectrum is best described by the sum of a hard X-ray power law (Γ = 1.38_{-0.03}^{+0.05}) and a soft component, approximated by a blackbody with kT_BB = 0.66_{-0.04}^{+0.05} keV (rest frame). If the spectrum of 4C+25.05 is interpreted in the context of bulk Comptonization by cold electrons of broad-line region photons emitted in the direction of the jet, such an unusual temperature implies a bulk Lorentz factor of the jet of Γbulk ∼ 11.7. Bulk Comptonization is expected to be ubiquitous on physical grounds, yet no clear signature of it has been found so far, possibly due to its transient nature and the lack of high-quality, broad-band X-ray spectra.

  19. Discovery of a new bona fide luminous blue variable in Norma

    Science.gov (United States)

    Gvaramadze, V. V.; Kniazev, A. Y.; Berdnikov, L. N.

    2015-12-01

    We report the results of optical spectroscopy of the candidate evolved massive star MN44 revealed via detection of a circular shell with the Spitzer Space Telescope. First spectra taken in 2009 May-June showed the Balmer lines in emission as well as numerous emission lines of iron, which is typical of luminous blue variables (LBVs) near the visual maximum. New observations carried out in 2015 May-September detected significant changes in the spectrum, indicating that the star became hotter. We found that these changes are accompanied by significant brightness variability of MN44. In particular, the Ic-band brightness decreased by ≈ 1.6 mag during the last six years and after reaching its minimum in 2015 June has started to increase. Using archival data, we also found that the Ic-band brightness increased by ≈3 mag in ≈30 yr preceding our observations. MN44 therefore represents the 17th known example of the Galactic bona fide LBVs. We detected a nitrogen-rich knot to the north-west of the star, which might represent an interstellar cloudlet interacting with the circumstellar shell. We discuss a possible association between MN44 and the INTEGRAL transient source of hard X-ray emission IGR J16327-4940, implying that MN44 might be either a colliding-wind binary or a high-mass X-ray binary.

  20. Gemini Near-infrared Spectroscopy of Luminous z~6 Quasars

    DEFF Research Database (Denmark)

    Jiang, Linhua; Fan, Xiaohui; Vestergaard, Marianne

    2007-01-01

    We present Gemini near-infrared spectroscopic observations of six luminous quasars at z=5.8$\\sim$6.3. Five of them were observed using Gemini-South/GNIRS, which provides a simultaneous wavelength coverage of 0.9--2.5 $\\mu$m in cross dispersion mode. The other source was observed in K band...... with Gemini-North/NIRI. We calculate line strengths for all detected emission lines and use their ratios to estimate gas metallicity in the broad-line regions of the quasars. The metallicity is found to be supersolar with a typical value of $\\sim$4 Z_{\\sun}, and a comparison with low-redshift observations...... shows no strong evolution in metallicity up to z$\\sim$6. The FeII/MgII ratio of the quasars is 4.9+/-1.4, consistent with low-redshift measurements. We estimate central BH masses of 10^9 to 10^{10} M_{\\sun} and Eddington luminosity ratios of order unity. We identify two MgII $\\lambda\\lambda$2796...

  1. Current status of CHESS - the Cornell High Energy Synchrotron Source

    International Nuclear Information System (INIS)

    Mills, D.; Cornell Univ., Ithaca, NY

    1982-01-01

    This paper reviews the status of CHESS through its three-year construction period, which ends in the fall of 1981. Included are a brief description of beam lines, monochromators, station instrumentations and support facilities. Our experiences with source size and stability over the last year are reported, along with planned fall revisions and running schedule. (orig.)

  2. High brightness single photon sources based on photonic wires

    DEFF Research Database (Denmark)

    Claudon, J.; Bleuse, J.; Bazin, M.

    2009-01-01

    We present a novel single-photon-source based on the emission of a semiconductor quantum dot embedded in a single-mode photonic wire. This geometry ensures a very large coupling (> 95%) of the spontaneous emission to the guided mode. Numerical simulations show that a photon collection efficiency...

  3. WARM MOLECULAR GAS IN LUMINOUS INFRARED GALAXIES

    Energy Technology Data Exchange (ETDEWEB)

    Lu, N.; Zhao, Y.; Xu, C. K.; Mazzarella, J. M.; Howell, J.; Appleton, P.; Lord, S.; Schulz, B. [Infrared Processing and Analysis Center, California Institute of Technology, MS 100-22, Pasadena, CA 91125 (United States); Gao, Y. [Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008 (China); Armus, L.; Díaz-Santos, T.; Surace, J. [Spitzer Science Center, California Institute of Technology, MS 220-6, Pasadena, CA 91125 (United States); Isaak, K. G. [ESA Astrophysics Missions Division, ESTEC, P.O. Box 299, 2200-AG Noordwijk (Netherlands); Petric, A. O. [Gemini Observatory, 670 N. A' ohoku Place, Hilo, HI 96720 (United States); Charmandaris, V. [Department of Physics, University of Crete, GR-71003 Heraklion (Greece); Evans, A. S. [Department of Astronomy, University of Virginia, 530 McCormick Road, Charlottesville, VA 22904 (United States); Inami, H. [National Optical Astronomy Observatory, Tucson, AZ 85719 (United States); Iwasawa, K. [ICREA and Institut de Ciències del Cosmos (ICC), Universitat de Barcelona (IEEC-UB), Martí i Franquès 1, E-08028 Barcelona (Spain); Leech, J. [Department of Physics, University of Oxford, Denys Wilkinson Building, Keble Road, Oxford OX1 3RH (United Kingdom); Sanders, D. B., E-mail: lu@ipac.caltech.edu [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States); and others

    2014-06-01

    We present our initial results on the CO rotational spectral line energy distribution (SLED) of the J to J–1 transitions from J = 4 up to 13 from Herschel SPIRE spectroscopic observations of 65 luminous infrared galaxies (LIRGs) in the Great Observatories All-Sky LIRG Survey. The observed SLEDs change on average from one peaking at J ≤ 4 to a broad distribution peaking around J ∼ 6 to 7 as the IRAS 60-to-100 μm color, C(60/100), increases. However, the ratios of a CO line luminosity to the total infrared luminosity, L {sub IR}, show the smallest variation for J around 6 or 7. This suggests that, for most LIRGs, ongoing star formation (SF) is also responsible for a warm gas component that emits CO lines primarily in the mid-J regime (5 ≲ J ≲ 10). As a result, the logarithmic ratios of the CO line luminosity summed over CO (5–4), (6–5), (7–6), (8–7) and (10–9) transitions to L {sub IR}, log R {sub midCO}, remain largely independent of C(60/100), and show a mean value of –4.13 (≡log R{sub midCO}{sup SF}) and a sample standard deviation of only 0.10 for the SF-dominated galaxies. Including additional galaxies from the literature, we show, albeit with a small number of cases, the possibility that galaxies, which bear powerful interstellar shocks unrelated to the current SF, and galaxies, in which an energetic active galactic nucleus contributes significantly to the bolometric luminosity, have their R {sub midCO} higher and lower than R{sub midCO}{sup SF}, respectively.

  4. Production of L-Asparaginase by the marine luminous bacteria

    Digital Repository Service at National Institute of Oceanography (India)

    Ramaiah, N.; Chandramohan, D.

    Fortythree strains of luminous bacteria, belonging to 4 species, (Vibrio harveyi, V. fischeri, Photobacterium leiognathi and P. phosphoreum) isolated from different marine samples, were examined for the production of L-asparaginase. Presence...

  5. Predicting daylight illuminance on inclined surfaces using sky luminance data

    Energy Technology Data Exchange (ETDEWEB)

    Li, D.H.W.; Lau, C.C.S.; Lam, J.C. [City University of Hong Kong, Kowloon (China). Dept. of Building and Construction

    2005-07-01

    Daylight illuminance, particularly on vertical surfaces, plays a major role in determining and evaluating the daylighting performance of a building. In many parts of the world, however, the basic daylight illuminance data for various vertical planes are not always readily available. The usual method to obtain diffuse illuminance on tilted planes would be based on inclined surface models using data from the horizontal measurements. Alternatively, the diffuse illuminance on a sloping plane can be computed by integrating the luminance distribution of the sky 'seen' by the plane. This paper presents an approach to estimate the vertical outdoor illuminance from sky luminance data and solar geometry. Sky luminance data recorded from January 1999 to December 2001 in Hong Kong and generated by two well-known sky luminance models (Kittler and Perez) were used to compute the outdoor illuminance for the four principal vertical planes (N, E, S and W). The performance of this approach was evaluated against data measured in the same period. Statistical analysis indicated that using sky luminance distributions to predict outdoor illuminance can give reasonably good agreement with measured data for all vertical surfaces. The findings provide an accurate alternative to determine the amount of daylight on vertical as well as other inclined surfaces when sky luminance data are available. (author)

  6. Dynamics of backlight luminance for using smartphone in dark environment

    Science.gov (United States)

    Na, Nooree; Jang, Jiho; Suk, Hyeon-Jeong

    2014-02-01

    This study developed dynamic backlight luminance, which gradually changes as time passes for comfortable use of a smartphone display in a dark environment. The study was carried out in two stages. In the first stage, a user test was conducted to identify the optimal luminance by assessing the facial squint level, subjective glare evaluation, eye blink frequency and users' subjective preferences. Based on the results of the user test, the dynamics of backlight luminance was designed. It has two levels of luminance: the optimal level for initial viewing to avoid sudden glare or fatigue to users' eyes, and the optimal level for constant viewing, which is comfortable, but also bright enough for constant reading of the displayed material. The luminance for initial viewing starts from 10 cd/m2, and it gradually increases to 40 cd/m2 for users' visual comfort at constant viewing for 20 seconds; In the second stage, a validation test on dynamics of backlight luminance was conducted to verify the effectiveness of the developed dynamics. It involving users' subjective preferences, eye blink frequency, and brainwave analysis using the electroencephalogram (EEG) to confirm that the proposed dynamic backlighting enhances users' visual comfort and visual cognition, particularly for using smartphones in a dark environment.

  7. Detection of chromatic and luminance distortions in natural scenes.

    Science.gov (United States)

    Jennings, Ben J; Wang, Karen; Menzies, Samantha; Kingdom, Frederick A A

    2015-09-01

    A number of studies have measured visual thresholds for detecting spatial distortions applied to images of natural scenes. In one study, Bex [J. Vis.10(2), 1 (2010)10.1167/10.2.231534-7362] measured sensitivity to sinusoidal spatial modulations of image scale. Here, we measure sensitivity to sinusoidal scale distortions applied to the chromatic, luminance, or both layers of natural scene images. We first established that sensitivity does not depend on whether the undistorted comparison image was of the same or of a different scene. Next, we found that, when the luminance but not chromatic layer was distorted, performance was the same regardless of whether the chromatic layer was present, absent, or phase-scrambled; in other words, the chromatic layer, in whatever form, did not affect sensitivity to the luminance layer distortion. However, when the chromatic layer was distorted, sensitivity was higher when the luminance layer was intact compared to when absent or phase-scrambled. These detection threshold results complement the appearance of periodic distortions of the image scale: when the luminance layer is distorted visibly, the scene appears distorted, but when the chromatic layer is distorted visibly, there is little apparent scene distortion. We conclude that (a) observers have a built-in sense of how a normal image of a natural scene should appear, and (b) the detection of distortion in, as well as the apparent distortion of, natural scene images is mediated predominantly by the luminance layer and not chromatic layer.

  8. Verification of high efficient broad beam cold cathode ion source

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Reheem, A. M., E-mail: amreheem2009@yahoo.com [Accelerators and Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.N.13759, Cairo (Egypt); Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), Cairo (Egypt); Ahmed, M. M. [Physics Department, Faculty of Science, Helwan University, Cairo (Egypt); Abdelhamid, M. M.; Ashour, A. H. [Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), Cairo (Egypt)

    2016-08-15

    An improved form of cold cathode ion source has been designed and constructed. It consists of stainless steel hollow cylinder anode and stainless steel cathode disc, which are separated by a Teflon flange. The electrical discharge and output characteristics have been measured at different pressures using argon, nitrogen, and oxygen gases. The ion exit aperture shape and optimum distance between ion collector plate and cathode disc are studied. The stable discharge current and maximum output ion beam current have been obtained using grid exit aperture. It was found that the optimum distance between ion collector plate and ion exit aperture is equal to 6.25 cm. The cold cathode ion source is used to deposit aluminum coating layer on AZ31 magnesium alloy using argon ion beam current which equals 600 μA. Scanning electron microscope and X-ray diffraction techniques used for characterizing samples before and after aluminum deposition.

  9. High Power Broadband Multispectral Source on a Hybrid Silicon Chip

    Science.gov (United States)

    2017-03-14

    optical bandwidth of the erbium-doped- fiber -amplifier with densely-spaced frequency channels. To extend the spectral capacity of the Si-on-insulator...associated with non-uniform undercut at the taper tip across the chip after wet etching the active region. Figure 14. Normalized optical emission...Hutchinson, J., Shin, J.-H., Fish, G., and Fang, A., “Integrated silicon photonic laser sources for telecom and datacom,” in [National Fiber Optic

  10. sources

    Directory of Open Access Journals (Sweden)

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  11. Data sources on landscape structure in a highly industrialized area

    Directory of Open Access Journals (Sweden)

    Mazurek Kinga

    2015-03-01

    Full Text Available Landscape may be described as a part of space characterized by a certain physiognomy, which is a dynamic system subject to evolution. An important factor influencing the type and condition of the landscape is human activity which shapes or rebuilds its structure. Interesting results may be obtained on comparison of archival cartographic materials with contemporary studies and zoning plans. The Upper Silesian Coal Basin is a region with a clearly transformed landscape. The determinant of the geographical environment transformation here is the anthropogenic factor. The study area includes the upper part of the Kłodnica catchment (229.6 sq km. The study is a review, and its aim is to systematize data sources used in the research on the transformation of landscape structure of a heavily industrialized area. In the first half of the nineteenth century created the "Urmesstischblätter" in the scale of 1:25 000. Afterwards preparations began to take new topographic images of the country (the "Messtischblätter". In the 1990s initiated the development of a new topographic map (in the scale of 1:10 000. Recent data source is for example the project CORINE Land Cover 2006. There are many of various sources of data on land cover. An important aspect is the proper selection of documents and maps, and their proper interpretation.

  12. A ns-pulsed high-current electron beam source

    International Nuclear Information System (INIS)

    Guan, Gexin; Li, Youzhi; Pan, Yuli

    1988-01-01

    The behaviour of a pulse electron beam source which is composed of a gun and pulse system depends on not only the time characteristics of the gun and the pulser, but also their combination. This point become apparent if effects of the electron tansit-time between electrodes are studied. A ferrite transmission line (FTL) pulser is used as a grid driver in this source. It has advantages of providing fast risetime, large peak power output and good loading characteristics. It is these advantages of the pulser that compensates the absence of some technological conditions of manufacturing gun and makes the source better. Our testing showed that the cooperation of both the gun and the pulser produced peak currents in the range of 1 to 9 amps with widths of 2 to 2.5 ns (FWHM) at cathode-to-anode potential of 60 to 82 kv, while the grid drives are about in the range of 1 to 3 kv. In addition, the results of the testing instructed that effects of electron transit-time cannot be ignored when the pulses with widths of several nanoseconds are used as a grid drive. Based on the results, electron transit-time effects on the design of the gun and the beam performances are briefly descussed in this paper. (author)

  13. High Throughput PBTK: Open-Source Data and Tools for ...

    Science.gov (United States)

    Presentation on High Throughput PBTK at the PBK Modelling in Risk Assessment meeting in Ispra, Italy Presentation on High Throughput PBTK at the PBK Modelling in Risk Assessment meeting in Ispra, Italy

  14. Measuring the fractal dimension of the seismic source through the high-frequency fall-off of source spectra

    International Nuclear Information System (INIS)

    Wu, Z.L.; Chen, Y.T.; Kim, S.G.

    1995-09-01

    Using the Wigner-distribution estimation, the high-frequency fall-off of source spectra was estimated. The technique was applied to the analysis of the source spectra of the July 22, 1994, Vladivostok M6.4 deep-focus earthquake and that of the July 22, 1994, Northern Japan Sea M5.7 deep-focus earthquake. It is shown that the high-frequency fall-off of the source spectra of these two earthquakes may be characterized by two parts. Between the first corner frequency f 1 and the second corner frequency f 2 , the high-frequency fall-off of the source spectra can be represented by f 5.0 : above f 2 , the high-frequency fall-off can be represented by f 1.4 . In the perspective of the fractal geometry of earthquake source, it seems that the deep-focus earthquakes under consideration may be characterized as being composed of some 'sub events'. On the other hand, each sub event has its complex structure. (author). 12 refs, 3 figs, 1 tab

  15. Advancing Our Understanding of the Etiologies and Mutational Landscapes of Basal Like, Luminal A, and Luminal B Breast Cancers

    Science.gov (United States)

    2016-10-01

    will be further analyzed for effects on reading frame and protein structure and function using analysis and prediction tools such as PolyPhen and...luminal A, and luminal B tumors. Originally this study intended to include 900 newly diagnosed first primary triple negative (TN) invasive breast cancer...breast cancer risk factors. At the end of the interview participants will be asked to donate an oral tissue specimen for future genetic testing. Medical

  16. Performance of the SLC polarized electron source with high polarization

    International Nuclear Information System (INIS)

    Clendenin, J.E.; Alley, R.K.; Aoyagi, H.

    1993-04-01

    For the 1992 operating cycle of the SLAC Linear Collider (SLC), the polarized electron source (PES) during its maiden run successfully met the pulse intensity and overall efficiency requirements of the SLC. However, the polarization of the bulk GaAs cathode was low (∼27%) and the pulse-to-pulse stability was marginal. We have shown that adequate charge for the SLC can be extracted from a strained layer cathode having P e ∼80% even though the quantum efficiency (QE) is - beam stability. The performance of the PES during the 1993 SLC operating cycle with these and other improvements is discussed

  17. The role of luminance and chromatic cues in emmetropisation.

    Science.gov (United States)

    Rucker, Frances J

    2013-05-01

    At birth most, but not all eyes, are hyperopic. Over the course of the first few years of life the refraction gradually becomes close to zero through a process called emmetropisation. This process is not thought to require accommodation, though a lag of accommodation has been implicated in myopia development, suggesting that the accuracy of accommodation is an important factor. This review will cover research on accommodation and emmetropisation that relates to the ability of the eye to use colour and luminance cues to guide the responses. There are three ways in which changes in luminance and colour contrast could provide cues: (1) The eye could maximize luminance contrast. Monochromatic light experiments have shown that the human eye can accommodate and animal eyes can emmetropise using changes in luminance contrast alone. However, by reducing the effectiveness of luminance cues in monochromatic and white light by introducing astigmatism, or by reducing light intensity, investigators have revealed that the eye also uses colour cues in emmetropisation. (2) The eye could compare relative cone contrast to derive the sign of defocus information from colour cues. Experiments involving simulations of the retinal image with defocus have shown that relative cone contrast can provide colour cues for defocus in accommodation and emmetropisation. In the myopic simulation the contrast of the red component of a sinusoidal grating was higher than that of the green and blue component and this caused relaxation of accommodation and reduced eye growth. In the hyperopic simulation the contrast of the blue component was higher than that of the green and red components and this caused increased accommodation and increased eye growth. (3) The eye could compare the change in luminance and colour contrast as the eye changes focus. An experiment has shown that changes in colour or luminance contrast can provide cues for defocus in emmetropisation. When the eye is exposed to colour

  18. Radiation properties of two types of luminous textile devices containing plastic optical fibers

    Science.gov (United States)

    Selm, Bärbel; Rothmaier, Markus

    2007-05-01

    Luminous textiles have the potential to satisfy a need for thin and flexible light diffusers for treatment of intraoral cancerous tissue. Plastic optical fibers (POF) with diameters of 250 microns and smaller are used to make the textiles luminous. Usually light is supplied to the optical fiber at both ends. On the textile surface light emission occurs in a woven structure via damaged straight POFs, whereas the embroidered structure radiates the light out of macroscopically bent POFs. We compared the optical properties of these two types of textile diffusers using red light laser for the embroidery and light emitting diode (LED) for the woven structure as light sources, and found efficiencies for the luminous areas of the two samples of 19 % (woven) and 32 % (embroidery), respectively. It was shown that the efficiency can be greatly improved using an aluminium backing. Additional scattering layers lower the fluence rate by around 30 %. To analyse the homogeneity we took a photo of the illuminated surface using a 3CCD camera and found, for both textiles, a slightly skewed distribution of the dark and bright pixels. The interquartile range of brightness distribution of the embroidery is more than double as the woven structure.

  19. Notch3 marks clonogenic mammary luminal progenitor cells in vivo.

    Science.gov (United States)

    Lafkas, Daniel; Rodilla, Veronica; Huyghe, Mathilde; Mourao, Larissa; Kiaris, Hippokratis; Fre, Silvia

    2013-10-14

    The identity of mammary stem and progenitor cells remains poorly understood, mainly as a result of the lack of robust markers. The Notch signaling pathway has been implicated in mammary gland development as well as in tumorigenesis in this tissue. Elevated expression of the Notch3 receptor has been correlated to the highly aggressive "triple negative" human breast cancer. However, the specific cells expressing this Notch paralogue in the mammary gland remain unknown. Using a conditionally inducible Notch3-CreERT2(SAT) transgenic mouse, we genetically marked Notch3-expressing cells throughout mammary gland development and followed their lineage in vivo. We demonstrate that Notch3 is expressed in a highly clonogenic and transiently quiescent luminal progenitor population that gives rise to a ductal lineage. These cells are capable of surviving multiple successive pregnancies, suggesting a capacity to self-renew. Our results also uncover a role for the Notch3 receptor in restricting the proliferation and consequent clonal expansion of these cells.

  20. Compact high efficiency, light weight 200-800 MHz high power RF source

    International Nuclear Information System (INIS)

    Shrader, M.B.; Preist, D.H.

    1985-01-01

    There has long been a need for a new more efficient less bulky high power RF power source to drive accelerators in the 200 to 800 MHz region. Results on a recent 5-year EIMAC sponsored R and D program which have lead to the introduction of the Klystrode for UHF television and troposcatter applications indicate that at power levels of 1MW or more efficiencies in excess of 75% can be obtained at 450 MHz. Efficiencies of this order coupled with potential size and weight parameters which are a fraction of those of existing high power UHF generators open up new applications which heretofore would have been impractical if not impossible. Measurements at 470 MHz on existing Klystrodes are given. Projected operating conditions for a 1MW 450 MHz Klystrode having an overall length of 60 inches and a total tube, circuit, and magnet weight of 250 pounds is presented

  1. Collision experiment on highly ionized ions using vacuum spark source

    International Nuclear Information System (INIS)

    Takagi, S.; Ohtani, S.; Kadota, K.; Fujita, J.

    1982-03-01

    Cross sections for one-electron capture by Fe 6 + in H 2 are measured below 10 keV by using a vacuum spark ion source. It is found that the cross sections show little dependence on the collision energy and this value is about 6 x 10 - 15 cm 2 . This ion source, which has no electrode for ion extraction, can produce ions from several hundreds eV to several tens of keV and the maximum charge state of 16 in Fe at 125J discharge energy. With ion selection system of 2.7 m time-of-flight and an electrostatic analyzer of 1% resolving power, 10 2 - 10 3 ions/pulse are obtained. Because of poor reproducibility of ion beam, charge-transferred ions and unreacted ions are measured simultaneously with a microchannel plate which has two anodes behind. By utilizing the feature of pulsed ion beam and this ion selection system, it is possible to obtain cross sections for various charge states of ions simultaneously. (author)

  2. Recovery of spent high intensity neutron sources in Atalante Facility

    International Nuclear Information System (INIS)

    Bros, P.; Boyer Deslys, V.; Millet, A.; Solinhac, I.; Donnet, L.; Maillard, C.; Paillard, S.; Ranchoux, M.

    2005-01-01

    The Atalante facility is required by law to recover both neutron and gamma sources with activity levels exceeding 300 mCi. Most of the neutron sources consist of mixtures of alpha-emitters (238Pu, 239Pu, 241Am or 244Cm) and beryllium. Several processes now under consideration are based on routine chemical separation techniques (selective precipitation, extraction chromatography, ion exchange). The treatment produces an actinide oxide (which is used later for R and D studies) and solid beryllium nitrate, which is considered as a waste and transferred to a surface interim storage site if the overall activity of the package after 300 years is less than 50 MBq (ANDRA specifications). The Material Analysis and Metrology Laboratory of Atalante validate the residual alpha activity in the waste. The techniques used include alpha spectrometry and L-line X-ray fluorescence for alpha emitters, and plasma torch measurements (ICP-AES and ICP-MS) for beryllium analysis. Specific equipment for transport (B type cask), storage and treatment (hot shielded cells) are used for this activity. (Author)

  3. Beam commission of the high intensity proton source developed at INFN-LNS for the European Spallation Source

    Science.gov (United States)

    Neri, L.; Celona, L.; Gammino, S.; Miraglia, A.; Leonardi, O.; Castro, G.; Torrisi, G.; Mascali, D.; Mazzaglia, M.; Allegra, L.; Amato, A.; Calabrese, G.; Caruso, A.; Chines, F.; Gallo, G.; Longhitano, A.; Manno, G.; Marletta, S.; Maugeri, A.; Passarello, S.; Pastore, G.; Seminara, A.; Spartà, A.; Vinciguerra, S.

    2017-07-01

    At the Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali del Sud (INFN-LNS) the beam commissioning of the high intensity Proton Source for the European Spallation Source (PS-ESS) started in November 2016. Beam stability at high current intensity is one of the most important parameter for the first steps of the ongoing commissioning. Promising results were obtained since the first source start with a 6 mm diameter extraction hole. The increase of the extraction hole to 8 mm allowed improving PS-ESS performances and obtaining the values required by the ESS accelerator. In this work, extracted beam current characteristics together with Doppler shift and emittance measurements are presented, as well as the description of the next phases before the installation at ESS in Lund.

  4. Candidate luminal B breast cancer genes identified by genome, gene expression and DNA methylation profiling.

    Directory of Open Access Journals (Sweden)

    Stéphanie Cornen

    Full Text Available Breast cancers (BCs of the luminal B subtype are estrogen receptor-positive (ER+, highly proliferative, resistant to standard therapies and have a poor prognosis. To better understand this subtype we compared DNA copy number aberrations (CNAs, DNA promoter methylation, gene expression profiles, and somatic mutations in nine selected genes, in 32 luminal B tumors with those observed in 156 BCs of the other molecular subtypes. Frequent CNAs included 8p11-p12 and 11q13.1-q13.2 amplifications, 7q11.22-q34, 8q21.12-q24.23, 12p12.3-p13.1, 12q13.11-q24.11, 14q21.1-q23.1, 17q11.1-q25.1, 20q11.23-q13.33 gains and 6q14.1-q24.2, 9p21.3-p24,3, 9q21.2, 18p11.31-p11.32 losses. A total of 237 and 101 luminal B-specific candidate oncogenes and tumor suppressor genes (TSGs presented a deregulated expression in relation with their CNAs, including 11 genes previously reported associated with endocrine resistance. Interestingly, 88% of the potential TSGs are located within chromosome arm 6q, and seven candidate oncogenes are potential therapeutic targets. A total of 100 candidate oncogenes were validated in a public series of 5,765 BCs and the overexpression of 67 of these was associated with poor survival in luminal tumors. Twenty-four genes presented a deregulated expression in relation with a high DNA methylation level. FOXO3, PIK3CA and TP53 were the most frequent mutated genes among the nine tested. In a meta-analysis of next-generation sequencing data in 875 BCs, KCNB2 mutations were associated with luminal B cases while candidate TSGs MDN1 (6q15 and UTRN (6q24, were mutated in this subtype. In conclusion, we have reported luminal B candidate genes that may play a role in the development and/or hormone resistance of this aggressive subtype.

  5. High-Speed Fuses in IGBT based Voltage Source Converters

    DEFF Research Database (Denmark)

    Iov, Florin; Blaabjerg, Frede; Rasmussen, Henrik

    2005-01-01

    The demand for protection of power electronic applications has during the last couple of years increased regarding the high-power IGBT modules. Even with an active protection, a high power IGBT still has a risk of exhibiting a violent rupture in the case of a fault if IGBT fuses do not protect it...... protection. First, the problem of adding inductance in the DC-link circuit is treated, second a short discussion of the protection of the IGBT module is done, and finally, the impact of the high frequency loading on the current carrying capability of the fuses is presented....

  6. High peak power THz source for ultrafast electron diffraction

    Directory of Open Access Journals (Sweden)

    Shengguang Liu

    2018-01-01

    Full Text Available Terahertz (THz science and technology have already become the research highlight at present. In this paper, we put forward a device setup to carry out ultrafast fundamental research. A photocathode RF gun generates electron bunches with ∼MeV energy, ∼ps bunch width and about 25pC charge. The electron bunches inject the designed wiggler, the coherent radiation at THz spectrum emits from these bunches and increases rapidly until the saturation at ∼MW within a short wiggler. THz pulses can be used as pump to stimulate an ultra-short excitation in some kind of sample. Those electron bunches out of wiggler can be handled into bunches with ∼1pC change, small beam spot and energy spread to be probe. Because the pump and probe comes from the same electron source, synchronization between pump and probe is inherent. The whole facility can be compacted on a tabletop.

  7. Source conductance scaling for high frequency superconducting quasiparticle receivers

    Science.gov (United States)

    Ke, Qing; Feldman, M. J.

    1992-01-01

    It has been suggested that the optimum source conductance G(sub s) for the superconductor-insulator-superconductor (SIS) quasiparticle mixer should have a l/f dependence. This would imply that the critical current density of SIS junctions used for mixing should increase as frequency squared, a stringent constraint on the design of submillimeter SIS mixers, rather than in simple proportion to frequency as previously believed. We have used Tucker's quantum theory of mixing for extensive numerical calculations to determine G(sub s) for an optimized SIS receiver. We find that G(sub s) is very roughly independent of frequency (except for the best junctions at low frequency), and discuss the implications of our results for the design of submillimeter SIS mixers.

  8. The photonic nanowire: A highly efficient single-photon source

    DEFF Research Database (Denmark)

    Gregersen, Niels

    2014-01-01

    The photonic nanowire represents an attractive platform for a quantum light emitter. However, careful optical engineering using the modal method, which elegantly allows access to all relevant physical parameters, is crucial to ensure high efficiency.......The photonic nanowire represents an attractive platform for a quantum light emitter. However, careful optical engineering using the modal method, which elegantly allows access to all relevant physical parameters, is crucial to ensure high efficiency....

  9. The efficient model to define a single light source position by use of high dynamic range image of 3D scene

    Science.gov (United States)

    Wang, Xu-yang; Zhdanov, Dmitry D.; Potemin, Igor S.; Wang, Ying; Cheng, Han

    2016-10-01

    One of the challenges of augmented reality is a seamless combination of objects of the real and virtual worlds, for example light sources. We suggest a measurement and computation models for reconstruction of light source position. The model is based on the dependence of luminance of the small size diffuse surface directly illuminated by point like source placed at a short distance from the observer or camera. The advantage of the computational model is the ability to eliminate the effects of indirect illumination. The paper presents a number of examples to illustrate the efficiency and accuracy of the proposed method.

  10. Development and Application of a Microfluidics-Based Panel in the Basal/Luminal Transcriptional Characterization of Archival Bladder Cancers.

    Directory of Open Access Journals (Sweden)

    Doris Kim

    Full Text Available In the age of personalized medicine stratifying tumors into molecularly defined subtypes associated with distinctive clinical behaviors and predictable responses to therapies holds tremendous value. Towards this end, we developed a custom microfluidics-based bladder cancer gene expression panel for characterization of archival clinical samples. In silico analysis indicated that the content of our panel was capable of accurately segregating bladder cancers from several public datasets into the clinically relevant basal and luminal subtypes. On a technical level, our bladder cancer panel yielded robust and reproducible results when analyzing formalin-fixed, paraffin-embedded (FFPE tissues. We applied our panel in the analysis of a novel set of 204 FFPE samples that included non-muscle invasive bladder cancers (NMIBCs, muscle invasive disease (MIBCs, and bladder cancer metastases (METs. We found NMIBCs to be mostly luminal-like, MIBCs to include both luminal- and basal-like types, and METs to be predominantly of a basal-like transcriptional profile. Mutational analysis confirmed the expected enrichment of FGFR3 mutations in luminal samples, and, consistently, FGFR3 IHC showed high protein expression levels of the receptor in these tumors. Our bladder cancer panel enables basal/luminal characterization of FFPE tissues and with further development could be used for stratification of bladder cancer samples in the clinic.

  11. Luminal and basolateral uptake of insulin in isolated perfused, proximal tubules

    International Nuclear Information System (INIS)

    Nielsen, S.; Nielsen, J.T.; Christensen, E.I.

    1987-01-01

    The present study was performed to quantitate compare the luminal and the peritubular uptake of 125 I-insulin in isolated, perfused, proximal tubules from rabbit kidneys. 125 I-insulin was added in physiological concentrations to either the perfusate or the bath fluid for 30 min. The luminal uptake in 30 min averaged 0.76 pg/mm at physiological concentrations and 18.0 pg/mm at high insulin concentrations. About 15-41% of the absorbed insulin was digested and 125 I-insulin at physiological and high concentrations in the bath was 0.136 and 0.318 pg, respectively. The data indicates that insulin is bound/absorbed at the basolateral membranes both by a saturable specific mechanism and a nonspecific, nonsaturable mechanism. The basolateral absorption constituted 15.2 and 1.8% of the total tubular extraction of insulin at physiological and high insulin concentrations, respectively. Electron microscope autoradiography showed that, after luminal as well as basolateral endocytosis, insulin was exclusively accumulated in endocytic vacuoles and lysosomes

  12. Source of high-voltage power supply for ozone generators at glow discharge

    International Nuclear Information System (INIS)

    Bruev, A.A.; Golota, V.I.; Zavada, L.M.; Taran, G.V.

    2000-01-01

    High-voltage power supply source on quasi-resonance inverter base which works at direct current regime is described. This source forms 20 kV voltage with 0 - 10 mA current regulation. It protects the source from current break-downs and feeds ozone generators at glow discharge

  13. High-brightness electron source driven by laser

    International Nuclear Information System (INIS)

    Zhao Kui; Geng Rongli; Wang Lifang

    1996-01-01

    A DC high-brightness laser driven by photo emissive electron gun is being developed at Beijing University, in order to produce 50∼100 ps electron bunches of high quality. The gun consists of a photocathode preparation chamber and a DC acceleration cavity. Different ways of fabricating photocathode, such as chemical vapor deposition, ion beam implantation and ion beam enhanced deposition, can be adopted. The acceleration gap is designed with the aid of simulation codes EGUN and POISSON. 100 kV DC high voltage is fed to the anode through a careful designed ceramic insulator. The laser system is a mode locked Nd-YAG oscillator proceeded by an amplifier at 10 Hz repetition rate, which can deliver three different wavelength (1064/532/266 nm). The combination of a superconducting cavity with the photocathode preparation chamber is discussed

  14. Luminal nucleotides are tonic inhibitors of renal tubular transport

    DEFF Research Database (Denmark)

    Leipziger, Jens Georg

    2011-01-01

    PURPOSE OF REVIEW: Extracellular ATP is an essential local signaling molecule in all organ systems. In the kidney, purinergic signaling is involved in an array of functions and this review highlights those of relevance for renal tubular transport. RECENT FINDINGS: Purinergic receptors are express...... discovered as an important signaling compartment in which local purinergic signaling determines an inhibitory tone for renal tubular transport. Blocking components of this system leads to tubular hyper-absorption, volume retention and elevated blood pressure.......PURPOSE OF REVIEW: Extracellular ATP is an essential local signaling molecule in all organ systems. In the kidney, purinergic signaling is involved in an array of functions and this review highlights those of relevance for renal tubular transport. RECENT FINDINGS: Purinergic receptors are expressed...... in all renal tubular segments and their stimulation generally leads to transport inhibition. Recent evidence has identified the tubular lumen as a restricted space for purinergic signaling. The concentrations of ATP in the luminal fluids are sufficiently high to inflict a tonic inhibition of renal...

  15. Confirmation of the Luminous Blue Variable Status of MWC 930

    Directory of Open Access Journals (Sweden)

    A. S. Miroshnichenko

    2014-01-01

    Full Text Available We present spectroscopic and photometric observations of the emission-line star MWC 930 (V446 Sct during its long-term optical brightening in 2006–2013. Based on our earlier data we suggested that the object has features found in Luminous Blue Variables (LBV, such as a high luminosity (~3 105 L⊙, a low wind terminal velocity (~140 km s−1, and a tendency to show strong brightness variations (~1 mag over 20 years. For the last ~7 years it has been exhibiting a continuous optical and near-IR brightening along with a change of the emission-line spectrum appearance and cooling of the star’s photosphere. We present the object’s V-band light curve, analyze the spectral variations, and compare the observed properties with those of other recognized Galactic LBVs, such as AG Car and HR Car. Overall we conclude the MWC 930 is a bona fide Galactic LBV that is currently in the middle of an S Dor cycle.

  16. The Formation of Primordial Luminous Objects

    International Nuclear Information System (INIS)

    Ripamonti, Emanuele; Kapteyn Astron. Inst., Groningen; Abel, Tom; KIPAC, Menlo Park

    2005-01-01

    leave the discussion of feedback to lecture notes by Ferrara and Salvaterra and by Madau and Haardt in this same book and focus only on the aspects of the formation of the first objects. The advent of cosmological numerical hydrodynamics in particular allow a fresh new look at these questions. Hence, these notes will touch on aspects of theoretical cosmology to chemistry, computer science, hydrodynamics and atomic physics. For further reading and more references on the subject we refer the reader to other relevant reviews such as Barkana and Loeb 2001, and more recently Ciardi and Ferrara 2004, Glover 2004 and Bromm and Larson 2004. In these notes, we try to give a brief introduction to only the most relevant aspects. We will start with a brief overview of the relevant cosmological concepts in section 2, followed by a discussion of the properties of primordial material (with particular emphasis to its cooling and its chemistry) in section 3. We will then review the technique and the results of numerical simulations in sections 4 and 5: the former will deal with detailed 3D simulations of the formation of gaseous clouds which are likely to transform into luminous objects, while the latter will examine results (mostly from 1D codes) about the modalities of such transformation. Finally, in section 6 we will critically discuss the results of the previous sections, examining their consequences and comparing them to our present knowledge of the universe

  17. The nature of the Galactic Center source IRS 13 revealed by high spatial resolution in the infrared

    Science.gov (United States)

    Maillard, J. P.; Paumard, T.; Stolovy, S. R.; Rigaut, F.

    2004-08-01

    High spatial resolution observations in the 1 to 3.5 μm/ region of the Galactic Center source known historically as IRS 13 are presented. They include ground-based adaptive optics images in the H, Kp (2.12/0.4 μm) and L bands, HST-NICMOS data in filters between 1.1 and 2.2 μm, and integral field spectroscopic data from BEAR, an Imaging FTS, in the He I 2.06 μm/ and the Brγ line regions. Analysis of all these data provides a completely new picture of the main component, IRS 13E, which appears as a cluster of seven individual stars within a projected diameter of ˜0.5 arcsec (0.02 pc). The brightest sources, 13E1, 13E2, 13E3 which is detected as a binary, and 13E4, are all massive stars of different type. The star 13E1 is a luminous, blue object, with no detected emission line. 13E2 and 13E4 are two hot, high-mass emission line stars, 13E2 being at the WR stage and 13E4 a massive O-type star. In contrast, 13E3A and B are extremely red objects, proposed as other examples of dusty WR stars, like IRS 21 (Tanner et al. \\cite{tanner}). All these sources have a common westward proper motion (Ott et al. \\cite{ott2}) indicating they are bounded. Two other sources, detected after deconvolution of the AO images in the H and Kp bands, are also identified. One, that we call 13E5, is a red source similar to 13E3A and B, while the other one, 13E6, is probably a main sequence O star in front of the cluster. Considering this exceptional concentration of comoving massive hot stars, IRS 13E is proposed as the remaining core of a massive star cluster, which could harbor an intermediate-mass black hole (IMBH) (Portegies Zwart & McMillan \\cite{zwart2)} of ˜1300 M⊙. This detection plays in favor of a scenario, first suggested by Gerhard (\\cite{gerhard}), in which the helium stars and the other hot stars in the central parsec originate from the stripping of a massive cluster formed several tens of pc from the center. This cluster would have spiraled towards SgrA*, and IRS 13E

  18. The high pressure xenon lamp as a source of radiation

    International Nuclear Information System (INIS)

    Heerdt, J.A. ter.

    1979-01-01

    An account is given of an investigation into the radiation properties of a commercially available high pressure xenon lamp (type XBO 900 W) in the spectral range 0.3 to 3 μm. The purpose of the study was to find out whether such a lamp can serve as a (secondary) standard of radiation in spectroscopic and radiometric measurements. The main advantades of the xenon lamp over other secondary standards such as the tungsten strip lamp and the anode of a carbon arc lamp are the high temperature of its discharge and the resulting strong radiation over a broad spectral range. (Auth.)

  19. Development of a portable, high-energy radiographic source

    International Nuclear Information System (INIS)

    Reinhart, E.R.; Wenk, S.A.; Schonberg, R.G.; Mixon, G.L.

    1979-01-01

    The Electric Power Research Institute (EPRI) is sponsoring a two-year program to develop a portable, high-energy (3 to 4 MeV) radiographic system for inservice and repair inspections of components at nuclear power stations. The basic design concept uses a lightweight, portable linear accelerator (LINAC). The design objectives, concepts employed, and progress to date are described. Specific potential applications and accompanying radiographic techniques are discussed, along with the novel beam angulation devices to permit utilization in areas of highly restricted access

  20. Ceramics research in a high-energy neutron source

    International Nuclear Information System (INIS)

    Clinard, F.W. Jr.

    1989-01-01

    The studies on the irradiation effect to ceramics have added much to the basic understanding of their behavior, for example, the amorphous state of ceramics related to radiation-induced metamictization, the radiation-induced strengthening and toughening due to ultrafine defect aggregates, the in situ degradation of electrical resistivity, the role of radiation-induced defects on thermal conductivity and so on. Most of the irradiation testing on ceramics in the fields of structural and thermal properties have been carried out by using fast fission neutrons of about 1 MeV, but if this energy could be significantly changed, the size and nature of damage cascade and the quantity of transmutation gases produced would change. The significance of neutron source parameters, the special test requirement for ceramics such as the use of miniature specimens, the control of test environment, the transient reduction of electrical resistivity and so on are discussed. A special case of ceramic studies is that on new oxide superconductors. These materials can be made into amorphous state at about 1 dpa using 1 MeV electrons, and are considered to be fairly damage-sensitive. (K.I.)

  1. High current DC negative ion source for cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Etoh, H., E-mail: Hrh-Etoh@shi.co.jp; Aoki, Y.; Mitsubori, H.; Arakawa, Y.; Sakuraba, J.; Kato, T.; Mitsumoto, T.; Hiasa, T.; Yajima, S. [Sumitomo Heavy Industries, Ltd., Tokyo 141-6025 (Japan); Onai, M.; Hatayama, A. [Graduate School of Science and Technology, Keio University, Kanagawa 223-8522 (Japan); Shibata, T. [High Energy Accelerator Research Organization (KEK), Ibaraki 305-0801 (Japan); Okumura, Y. [Fusion Research and Development Directorate, Japan Atomic Energy Agency, Aomori 039-3212 (Japan)

    2016-02-15

    A filament driven multi-cusp negative ion source has been developed for proton cyclotrons in medical applications. In Cs-free operation, continuous H{sup −} beam of 10 mA and D{sup −} beam of 3.3 mA were obtained stably at an arc-discharge power of 3 kW and 2.4 kW, respectively. In Cs-seeded operation, H{sup −} beam current reached 22 mA at a lower arc power of 2.6 kW with less co-extracted electron current. The optimum gas flow rate, which gives the highest H{sup −} current, was 15 sccm in the Cs-free operation, while it decreased to 4 sccm in the Cs-seeded operation. The relationship between H{sup −} production and the design/operating parameters has been also investigated by a numerical study with KEIO-MARC code, which gives a reasonable explanation to the experimental results of the H{sup −} current dependence on the arc power.

  2. Assessment of atherosclerotic luminal narrowing of coronary arteries based on morphometrically generated visual guides.

    Science.gov (United States)

    Barth, Rolf F; Kellough, David A; Allenby, Patricia; Blower, Luke E; Hammond, Scott H; Allenby, Greg M; Buja, L Maximilian

    highly experienced cardiovascular pathologist. Interobserver reliability was assessed by determination of the intraclass correlation coefficient. The degrees of agreement for two H&E- and Movat-stained sections of the LADs from each of 10 decedents were 0.874 and 0.899, respectively, indicating strong interobserver agreement. On the average, the mean visual scores were ~8% less than the morphometric assessment (52.7 vs. 60.2), respectively. The visual guides that we have generated for scoring atherosclerotic luminal narrowing of coronary arteries should be helpful for a broad group of pathologists, from beginning pathology residents to experienced cardiovascular pathologists. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Association of proteasomal activity with metastasis in luminal breast cancer

    Science.gov (United States)

    Shashova, E. E.; Fesik, E. A.; Doroshenko, A. V.

    2017-09-01

    Chimotrypsin-like (ChTL) and caspase-like (CL) proteasomal activities were investigated in different variants of the tumor progression of luminal breast cancer. Patients with primary luminal breast cancer (n = 123) in stage T1-3N0-2M0 who had not received neoadjuvant treatment were included in this study. Proteasome ChTL and CL activities were determined in the samples of tumor and adjacent tissues. The coefficients of chymotrypsin-like (kChTL) and caspase-like (kCL) proteasome activity were also calculated as the ratio of the corresponding activity in the tumor tissue to activity in the adjacent tissue. ChTL, CL, kChTL and kCL in the tissues of luminal A and B breast cancer with lymphogenic metastasis were compared, and their association with hematogenous metastasis was evaluated. On the one hand, CL activity of proteasomes increased in luminal A breast cancer with extensive lymphogenic metastasis (N2), on the other hand it decreased in the luminal B subtype of cancer. The ratio of proteasomal activity in the tumor and adjacent tissues plays a significant role in the hematogenic pathway of breast cancer progression and is associated with poor metastatic-free survival.

  4. Very High Energy γ- rays from Galactic Sources

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    there are several upper limits: from the Adelaide group ( Edwards et al. 1994) at ... PSR 0355+54 is a pulsar with low timing noise indicating high internal ... 1995 and 1997, for an exposure of about 73 hours above 250 GeV, they give an upper.

  5. SOURCES OF PROFESSIONALISM, A STUDY OF HIGH SCHOOL TEACHERS.

    Science.gov (United States)

    COLOMBOTOS, JOHN L.

    AN INVESTIGATION WAS CONDUCTED OF THE DISTINCTIVE CHARACTERISTICS OF HIGH SCHOOL TEACHERS AS CONTRASTED WITH THEIR PEERS IN A BUSINESS ORGANIZATION. THE EFFECT OF THIS DISTINCTIVENESS ON THE PERSONAL NATURE OF TENSIONS AND CONFLICTS ASSOCIATED WITH JOB PERFORMANCE, CAREER GOALS, AND CAREER PATTERNS WAS ALSO STUDIED. ITS GENERAL OBJECTIVE WAS TO…

  6. High charge state heavy ion production from a PIG source

    International Nuclear Information System (INIS)

    Bex, L.; Clark, D.J.; Ellsworth, C.E.; Flood, W.S.; Gough, R.A.; Holley, W.R.; Meriwether, J.R.; Morris, D.

    1975-03-01

    The comparison of pulsed vs. dc arc operation for nitrogen and argon shows a shift in charge distribution toward the higher charge states for the pulsed case. Tests with various magnetic field shapes along the arc column show a significant increase in high charge state output for a uniform field compared to the case with a field low at the cathodes. (U.S.)

  7. ROLE OF DIAMOND SECONDARY EMITTERS IN HIGH BRIGHTNESS ELECTRON SOURCES

    International Nuclear Information System (INIS)

    2005-01-01

    In this paper we explore the possibility of using diamond secondary emitter in a high average current electron injector to amplify the current from the photocathode and to isolate the cathode and the injector from each other to increase the life time of the cathode and preserve the performance of the injector. Secondary electron yield of 225 and current density of 0.8 a/cm 2 have been measured in the transmission mode from type 2 a natural diamond. Although the diamond will be heated during normal operation in the injector, calculations indicate that by cryogenically cooling the diamond, the temperature gradient along the diamond can be maintained within the acceptable range. The electron energy and temporal distributions are expected to be narrow from this device resulting in high brightness beams. Plans are underway to measure the SEY in emission mode, fabricate photocathode-diamond capsule and test diamond and capsule in superconducting RF injector

  8. Silicon micromachining using a high-density plasma source

    International Nuclear Information System (INIS)

    McAuley, S.A.; Ashraf, H.; Atabo, L.; Chambers, A.; Hall, S.; Hopkins, J.; Nicholls, G.

    2001-01-01

    Dry etching of Si is critical in satisfying the demands of the micromachining industry. The micro-electro-mechanical systems (MEMS) community requires etches capable of high aspect ratios, vertical profiles, good feature size control and etch uniformity along with high throughput to satisfy production requirements. Surface technology systems' (STS's) high-density inductively coupled plasma (ICP) etch tool enables a wide range of applications to be realized whilst optimizing the above parameters. Components manufactured from Si using an STS ICP include accelerometers and gyroscopes for military, automotive and domestic applications. STS's advanced silicon etch (ASE TM ) has also allowed the first generation of MEMS-based optical switches and attenuators to reach the marketplace. In addition, a specialized application for fabricating the next generation photolithography exposure masks has been optimized for 200 mm diameter wafers, to depths of ∼750 μm. Where the profile is not critical, etch rates of greater than 8 μm min -1 have been realized to replace previous methods such as wet etching. This is also the case for printer applications. Specialized applications that require etching down to pyrex or oxide often result in the loss of feature size control at the interface; this is an industry wide problem. STS have developed a technique to address this. The rapid progression of the industry has led to development of the STS ICP etch tool, as well as the process. (author)

  9. High-intensity pulsed beam source with tunable operation mode

    Science.gov (United States)

    Nashilevskiy, A. V.; Kanaev, G. G.; Ezhov, V. V.; Shamanin, V. I.

    2017-05-01

    The report presents the design of an electron and an ion pulsed accelerator. The powerful high-voltage pulse generator of the accelerator and the vacuum bushing insulator is able to change the polarity of the output voltage. The low-inductance matching transformer provides an increase in the DFL output impedance by 4 times. The generator based on a high voltage pulse transformer and a pseudo spark switch is applied for DFL charging. The high-impedance magnetically insulated focusing diode with Br magnetic field and the “passive” anode was used to realize the ion beam generation mode. The plasma is formed on the surface of the anode caused by an electrical breakdown at the voltage edge pulse; as a result, the carbon ion and proton beam is generated. This beam has the following parameters: the current density is about 400 A/cm2 (in focus): the applied voltage is up to 450 kV. The accelerator is designed for the research on the interaction of the charged particle pulsed beams with materials and for the development of technological processes of a material modification.

  10. High-current Standing Wave Linac With Gyrocon Power Source

    CERN Document Server

    Karliner, M M; Makarov, I G; Nezhevenko, O A; Ostreiko, G N; Persov, B Z; Serdobintsev, G V

    2004-01-01

    A gyrocon together with high-voltage 1.5 MeV accelerator ELIT-3A represents a power generator at 430 MHz serving for linear electron accelerator pulse driving. The facility description and results of calorimetric measurements of ELIT-3A electron beam power and accelerated beam at the end of accelerator are presented in the paper. 2.2 amps of pulsed current have been obtained at electron energy of 20 MeV. The achieved energy conversion efficiency is about 55%.

  11. Report from the NSLS workshop: Sources and applications of high intensity uv-vuv light

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.D.; Hastings, J.B. (eds.)

    1990-01-01

    A workshop was held to evaluate sources and applications of high intensity, ultra violet (UV) radiation for biological, chemical, and materials sciences. The proposed sources are a UV free electron laser (FEL) driven by a high brightness linac and undulators in long, straight sections of a specially designed low energy (400 MeV) storage ring. These two distinct types of sources will provide a broad range of scientific opportunities that were discussed in detail during the workshop.

  12. Report from the NSLS workshop: Sources and applications of high intensity uv-vuv light

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.D.; Hastings, J.B. [eds.

    1990-12-31

    A workshop was held to evaluate sources and applications of high intensity, ultra violet (UV) radiation for biological, chemical, and materials sciences. The proposed sources are a UV free electron laser (FEL) driven by a high brightness linac and undulators in long, straight sections of a specially designed low energy (400 MeV) storage ring. These two distinct types of sources will provide a broad range of scientific opportunities that were discussed in detail during the workshop.

  13. Status of spallation neutron source program in High Intensity Proton Accelerator Project

    International Nuclear Information System (INIS)

    Oyama, Yukio

    2001-01-01

    Japan Atomic Energy Research Institute and High Energy Accelerator Organization are jointly designing a 1 MW spallation neutron source as one of the research facilities planned in the High Intensity Proton Accelerator Project. The spallation neutron source is driven by 3 GeV proton beam with a mercury target and liquid hydrogen moderators. The present status of design for these spallation source and relevant facility is overviewed. (author)

  14. Report from the NSLS workshop: Sources and applications of high intensity uv-vuv light

    International Nuclear Information System (INIS)

    Johnson, E.D.; Hastings, J.B.

    1990-01-01

    A workshop was held to evaluate sources and applications of high intensity, ultra violet (UV) radiation for biological, chemical, and materials sciences. The proposed sources are a UV free electron laser (FEL) driven by a high brightness linac and undulators in long, straight sections of a specially designed low energy (400 MeV) storage ring. These two distinct types of sources will provide a broad range of scientific opportunities that were discussed in detail during the workshop

  15. A New Diagnostic Diagram of Ionization Sources for High-redshift Emission Line Galaxies

    Science.gov (United States)

    Zhang, Kai; Hao, Lei

    2018-04-01

    We propose a new diagram, the kinematics–excitation (KEx) diagram, which uses the [O III] λ5007/Hβ line ratio and the [O III] λ5007 emission line width (σ [O III]) to diagnose the ionization source and physical properties of active galactic nuclei (AGNs) and star-forming galaxies (SFGs). The KEx diagram is a suitable tool to classify emission line galaxies at intermediate redshift because it uses only the [O III] λ5007 and Hβ emission lines. We use the main galaxy sample of SDSS DR7 and the Baldwin‑Phillips‑Terlevich (BPT) diagnostic to calibrate the diagram at low redshift. The diagram can be divided into three regions: the KEx-AGN region, which consists mainly of pure AGNs, the KEx-composite region, which is dominated by composite galaxies, and the KEx-SFG region, which contains mostly SFGs. LINERs strongly overlap with the composite and AGN regions. AGNs are separated from SFGs in this diagram mainly because they preferentially reside in luminous and massive galaxies and have higher [O III]/Hβ than SFGs. The separation between AGNs and SFGs is even cleaner thanks to the additional 0.15/0.12 dex offset in σ [O III] at fixed luminosity/stellar mass. We apply the KEx diagram to 7866 galaxies at 0.3 Survey, and compare it to an independent X-ray classification scheme using Chandra observations. X-ray AGNs are mostly located in the KEx-AGN region, while X-ray SFGs are mostly located in the KEx-SFG region. Almost all Type 1 AGNs lie in the KEx-AGN region. These tests support the reliability of this classification diagram for emission line galaxies at intermediate redshift. At z ∼ 2, the demarcation line between SFGs and AGNs is shifted by ∼0.3 dex toward higher values of σ [O III] due to evolution effects.

  16. Impact of Intestinal Microbiota on Intestinal Luminal Metabolome

    Science.gov (United States)

    Matsumoto, Mitsuharu; Kibe, Ryoko; Ooga, Takushi; Aiba, Yuji; Kurihara, Shin; Sawaki, Emiko; Koga, Yasuhiro; Benno, Yoshimi

    2012-01-01

    Low–molecular-weight metabolites produced by intestinal microbiota play a direct role in health and disease. In this study, we analyzed the colonic luminal metabolome using capillary electrophoresis mass spectrometry with time-of-flight (CE-TOFMS) —a novel technique for analyzing and differentially displaying metabolic profiles— in order to clarify the metabolite profiles in the intestinal lumen. CE-TOFMS identified 179 metabolites from the colonic luminal metabolome and 48 metabolites were present in significantly higher concentrations and/or incidence in the germ-free (GF) mice than in the Ex-GF mice (p metabolome and a comprehensive understanding of intestinal luminal metabolome is critical for clarifying host-intestinal bacterial interactions. PMID:22724057

  17. Luminal progenitors restrict their lineage potential during mammary gland development.

    Science.gov (United States)

    Rodilla, Veronica; Dasti, Alessandro; Huyghe, Mathilde; Lafkas, Daniel; Laurent, Cécile; Reyal, Fabien; Fre, Silvia

    2015-02-01

    The hierarchical relationships between stem cells and progenitors that guide mammary gland morphogenesis are still poorly defined. While multipotent basal stem cells have been found within the myoepithelial compartment, the in vivo lineage potential of luminal progenitors is unclear. Here we used the expression of the Notch1 receptor, previously implicated in mammary gland development and tumorigenesis, to elucidate the hierarchical organization of mammary stem/progenitor cells by lineage tracing. We found that Notch1 expression identifies multipotent stem cells in the embryonic mammary bud, which progressively restrict their lineage potential during mammary ductal morphogenesis to exclusively generate an ERαneg luminal lineage postnatally. Importantly, our results show that Notch1-labelled cells represent the alveolar progenitors that expand during pregnancy and survive multiple successive involutions. This study reveals that postnatal luminal epithelial cells derive from distinct self-sustained lineages that may represent the cells of origin of different breast cancer subtypes.

  18. Asymmetric effects of luminance and chrominance in the watercolor illusion

    Directory of Open Access Journals (Sweden)

    Andrew eCoia

    2014-09-01

    Full Text Available When bounded by a line of sufficient contrast, the desaturated hue of a colored line will spread over an enclosed area, an effect known as the watercolor illusion. The contrast of the two lines can be in luminance, chromaticity, or a combination of both. The effect is most salient when the enclosing line has greater contrast with the background than the line that induces the spreading color. In most prior experiments with watercolor spreading, the luminance of both lines has been lower than the background. An achromatic version of the illusion exists where a dark line will spread while being bounded by either a darker or brighter line. In a previous study we measured the strength of the watercolor effect in which the colored inducing line was isoluminant to the background, and found an illusion for both brighter and darker achromatic outer contours. We also found the strength of spreading is stronger for bluish (+S cone input colors compared to yellowish (-S cone input ones, when bounded by a dark line. The current study set out to measure the hue dependence of the watercolor illusion when inducing colors are flanked with brighter (increment as opposed to darker outer lines. The asymmetry in the watercolor effect with S cone input was enhanced when the inducing contrast was an increment rather than a decrement. Further experiments explored the relationship between the perceived contrast of these chromatic lines when paired with luminance increments and decrements and revealed that the perceived contrast of luminance increments and decrements is dependent on which isoluminant color they are paired with. In addition to known hue asymmetries in the watercolor illusion there are asymmetries between luminance increments and decrements that are also hue dependent. These latter asymmetries may be related to the perceived contrast of the hue/luminance parings.

  19. Asymmetric effects of luminance and chrominance in the watercolor illusion.

    Science.gov (United States)

    Coia, Andrew J; Crognale, Michael A

    2014-01-01

    When bounded by a line of sufficient contrast, the desaturated hue of a colored line will spread over an enclosed area, an effect known as the watercolor illusion. The contrast of the two lines can be in luminance, chromaticity, or a combination of both. The effect is most salient when the enclosing line has greater contrast with the background than the line that induces the spreading color. In most prior experiments with watercolor spreading, the luminance of both lines has been lower than the background. An achromatic version of the illusion exists where a dark line will spread while being bounded by either a darker or brighter line. In a previous study we measured the strength of the watercolor effect in which the colored inducing line was isoluminant to the background, and found an illusion for both brighter and darker achromatic outer contours. We also found the strength of spreading is stronger for bluish (+S cone input) colors compared to yellowish (-S cone input) ones, when bounded by a dark line. The current study set out to measure the hue dependence of the watercolor illusion when inducing colors are flanked with brighter (increment) as opposed to darker outer lines. The asymmetry in the watercolor effect with S cone input was enhanced when the inducing contrast was an increment rather than a decrement. Further experiments explored the relationship between the perceived contrast of these chromatic lines when paired with luminance increments and decrements and revealed that the perceived contrast of luminance increments and decrements is dependent on which isoluminant color they are paired with. In addition to known hue asymmetries in the watercolor illusion there are asymmetries between luminance increments and decrements that are also hue dependent. These latter asymmetries may be related to the perceived contrast of the hue/luminance parings.

  20. Human Mammary Luminal Epithelial Cells Contain Progenitors to Myoepithelial Cells

    Energy Technology Data Exchange (ETDEWEB)

    Pechoux, Christine; Gudjonsson, Thorarinn; Ronnov-Jessen, Lone; Bissell, Mina J; Petersen, Ole

    1999-02-01

    The origin of the epithelial and myoepithelial cells in the human breast has not been delineated. In this study we have addressed whether luminal epithelial cells and myoepithelial cells are vertically connected, i.e., whether one is the precursor for the other. We used a primary culture assay allowing preservation of basic phenotypic traits of luminal epithelial and myoepithelial cells in culture. The two cell types were then separated immunomagnetically using antibodies directed against lineage-specific cell surface antigens into at best 100% purity. The cellular identity was ascertained by cytochemistry, immunoblotting, and 2-D gel electrophoresis. Luminal epithelial cells were identified by strong expression of cytokeratins 18 and 19 while myoepithelial cells were recognized by expression of vimentin and {alpha}-smooth muscle actin. We used a previously devised culture medium (CDM4) that allows vigorous expansion of proliferative myoepithelial cells and also devised a medium (CDM6) that allowed sufficient expansion of differentiated luminal epithelial cells based on addition of hepatocyte growth factor/scatter factor. The two different culture media supported each lineage for at least five passages without signs of interconversion. We used parallel cultures where we switched culture media, thus testing the ability of each lineage to convert to the other. Whereas the myoepithelial lineage showed no signs of interconversion, a subset of luminal epithelial cells, gradually, but distinctly, converted to myoepithelial cells. We propose that in the mature human breast, it is the luminal epithelial cell compartment that gives rise to myoepithelial cells rather than the other way around.

  1. High power light gas helicon plasma source for VASIMR

    International Nuclear Information System (INIS)

    Squire, Jared P.; Chang-Diaz, Franklin R.; Glover, Timothy W.; Jacobson, Verlin T.; McCaskill, Greg E.; Winter, D. Scott; Baity, F. Wally; Carter, Mark D.; Goulding, Richard H.

    2006-01-01

    In the Advanced Space Propulsion Laboratory (ASPL) helicon experiment (VX-10) we have measured a plasma flux to input gas rate ratio near 100% for both helium and deuterium at power levels up to 10 kW. Recent results at Oak Ridge National Laboratory (ORNL) show enhanced efficiency operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 10 kW of input power. The data here uses a Boswell double-saddle antenna design with a magnetic cusp just upstream of the antenna. Similar to ORNL, for deuterium at near 10 kW, we find an enhanced performance of operation at magnetic fields above the lower hybrid matching condition

  2. GROMACS 4.5: a high-throughput and highly parallel open source molecular simulation toolkit.

    Science.gov (United States)

    Pronk, Sander; Páll, Szilárd; Schulz, Roland; Larsson, Per; Bjelkmar, Pär; Apostolov, Rossen; Shirts, Michael R; Smith, Jeremy C; Kasson, Peter M; van der Spoel, David; Hess, Berk; Lindahl, Erik

    2013-04-01

    Molecular simulation has historically been a low-throughput technique, but faster computers and increasing amounts of genomic and structural data are changing this by enabling large-scale automated simulation of, for instance, many conformers or mutants of biomolecules with or without a range of ligands. At the same time, advances in performance and scaling now make it possible to model complex biomolecular interaction and function in a manner directly testable by experiment. These applications share a need for fast and efficient software that can be deployed on massive scale in clusters, web servers, distributed computing or cloud resources. Here, we present a range of new simulation algorithms and features developed during the past 4 years, leading up to the GROMACS 4.5 software package. The software now automatically handles wide classes of biomolecules, such as proteins, nucleic acids and lipids, and comes with all commonly used force fields for these molecules built-in. GROMACS supports several implicit solvent models, as well as new free-energy algorithms, and the software now uses multithreading for efficient parallelization even on low-end systems, including windows-based workstations. Together with hand-tuned assembly kernels and state-of-the-art parallelization, this provides extremely high performance and cost efficiency for high-throughput as well as massively parallel simulations. GROMACS is an open source and free software available from http://www.gromacs.org. Supplementary data are available at Bioinformatics online.

  3. Effect of Ionizing Radiation on Luminous Bacteria Cells

    International Nuclear Information System (INIS)

    Kudryasheva, N.; Rozhko, T.; Alexandrova, M.; Vasyunkina, E.; Arkhipova, V.

    2011-01-01

    Marine luminous bacteria were used to monitor toxicity of alpha- (Am-241, U-235+238) and beta- (tritium) radionuclide solutions. Increase or inhibition of bacterial luminescence was observed under exposure to radionuclides. Radiation toxicity of Am and chemical toxicity of U were demonstrated. Effects of U were similar to those of stable heavy metals: sensitivity was about 10-5 M. Sensitivity of the bacteria to Am-241 was 300 Bq/L (10 -11 M). Inhibition of bacterial growth was observed under exposure to Am-241 and tritium. Role of peroxides and electron transfer processes in the effects of radionuclides on luminous bacteria is discussed.

  4. A Blind Pilot: Who is a Super-Luminal Observer?

    Directory of Open Access Journals (Sweden)

    Rabounski D.

    2008-04-01

    Full Text Available This paper discusses the nature of a hypothetical super-luminal observer who, as well as a real (sub-light speed observer, perceives the world by light waves. This consideration is due to that fact that the theory of relativity permits different frames of reference, including light-like and super-luminal reference frames. In analogy with a blind pilot on board a supersonic jet aeroplane (or missile, perceived by blind people, it is concluded that the light barrier is observed in the framework of only the light signal exchange experiment.

  5. Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons.

    Science.gov (United States)

    Ballester, Facundo; Granero, Domingo; Pérez-Calatayud, José; Melhus, Christopher S; Rivard, Mark J

    2009-09-01

    The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides (60Co, 137CS, 192Ir, and 169Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source beta-, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the 192Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Electronic equilibrium within 1% is reached for 60Co, 137CS, 192Ir, and 169Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for 60Co and 192Ir, respectively. Electron emissions become important (i.e., > 0.5%) within 3.3 mm of 60Co and 1.7 mm of 192Ir sources, yet are negligible over all distances for 137Cs and 169Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

  6. Clustering Batik Images using Fuzzy C-Means Algorithm Based on Log-Average Luminance

    Directory of Open Access Journals (Sweden)

    Ahmad Sanmorino

    2012-06-01

    Full Text Available Batik is a fabric or clothes that are made ​​with a special staining technique called wax-resist dyeing and is one of the cultural heritage which has high artistic value. In order to improve the efficiency and give better semantic to the image, some researchers apply clustering algorithm for managing images before they can be retrieved. Image clustering is a process of grouping images based on their similarity. In this paper we attempt to provide an alternative method of grouping batik image using fuzzy c-means (FCM algorithm based on log-average luminance of the batik. FCM clustering algorithm is an algorithm that works using fuzzy models that allow all data from all cluster members are formed with different degrees of membership between 0 and 1. Log-average luminance (LAL is the average value of the lighting in an image. We can compare different image lighting from one image to another using LAL. From the experiments that have been made, it can be concluded that fuzzy c-means algorithm can be used for batik image clustering based on log-average luminance of each image possessed.

  7. Luminal DMSO: Effects on Detrusor and Urothelial/Lamina Propria Function

    Directory of Open Access Journals (Sweden)

    Katrina J. Smith

    2014-01-01

    Full Text Available DMSO is used as a treatment for interstitial cystitis and this study examined the effects of luminal DMSO treatment on bladder function and histology. Porcine bladder was incubated without (controls or with DMSO (50% applied to the luminal surface and the release of ATP, acetylcholine, and LDH assessed during incubation and in tissues strips after DMSO incubation. Luminally applied DMSO caused ATP, Ach, and LDH release from the urothelial surface during treatment, with loss of urothelial layers also evident histologically. In strips of urothelium/lamina propria from DMSO pretreated bladders the release of both ATP and Ach was depressed, while contractile responses to carbachol were enhanced. Detrusor muscle contractile responses to carbachol were not affected by DMSO pretreatment, but neurogenic responses to electrical field stimulation were enhanced. The presence of an intact urothelium/lamina propria inhibited detrusor contraction to carbachol by 53% and this inhibition was significantly reduced in DMSO pretreated tissues. Detection of LDH in the treatment medium suggests that DMSO permeabilised urothelial membranes causing leakage of cytosolic contents including ATP and Ach rather than enhancing release of these mediators. The increase in contractile response and high levels of ATP are consistent with initial flare up in IC/PBS symptoms after DMSO treatment.

  8. A new high-temperature plasma ion source for the TRISTAN ISOL facility

    International Nuclear Information System (INIS)

    Piotrowski, A.; Gill, R.L.; McDonald, D.C.

    1987-01-01

    A vigorous program of ion-source development at TRISTAN has led to several types of ion sources that are especially suited to extended operation at a reactor-based ISOL facility. The latest of these is a high-temperature plasma ion source in which a 5-g /sup 235/U target is located in the cathode and can be heated to 2500 0 C. The ion source has a lifetime of > 1000 h and produces a wide array of elements, including palladium. Off-line investigations indicate that the source functions primarily in an electron impact mode of ionization and exhibits typical ionization efficiencies of > 30% for xenon

  9. A new high-temperature plasma ion source for the TRISTAN ISOL facility

    International Nuclear Information System (INIS)

    Piotrowski, A.; Gill, R.L.; McDonald, D.C.

    1987-01-01

    A vigorous program of ion-source development at TRISTAN has led to several types of ion sources that are especially suited to extended operation at a reactor-based ISOL facility. The latest of these is a high-temperature plasma ion source in which a 5-g 235 U target is located in the cathode and can be heated to 2500 0 C. The ion source has a lifetime of >1000 h and produces a wide array of elements, including palladium. Off-line investigations indicate that the source functions primarily in an electron impact mode of ionization and exhibits typical ionization efficiencies of >30% for xenon. (orig.)

  10. New high temperature plasma ion source for the TRISTAN ISOL facility

    International Nuclear Information System (INIS)

    Piotrowski, A.; Gill, R.L.; McDonald, D.C.

    1986-08-01

    A vigorous program of ion source development at TRISTAN has led to several types of ion sources that are especially suited to extended operation at a reactor-based ISOL facility. The latest of these is a high temperature plasma ion source in which a 5 gm 235 U target is located in the cathode and can be heated to 2500 0 C. The ion source has a lifetime of >1000 hours and produces a wide array of elements, including Pd. Off-line investigations indicate that the source functions primarily in an electron impact mode of ionization and exhibits typical ionzation efficiencies of >30% for Xe

  11. High voltage holding in the negative ion sources with cesium deposition

    Energy Technology Data Exchange (ETDEWEB)

    Belchenko, Yu.; Abdrashitov, G.; Ivanov, A.; Sanin, A.; Sotnikov, O., E-mail: O.Z.Sotnikov@inp.nsk.su [Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2016-02-15

    High voltage holding of the large surface-plasma negative ion source with cesium deposition was studied. It was found that heating of ion-optical system electrodes to temperature >100 °C facilitates the source conditioning by high voltage pulses in vacuum and by beam shots. The procedure of electrode conditioning and the data on high-voltage holding in the negative ion source with small cesium seed are described. The mechanism of high voltage holding improvement by depletion of cesium coverage is discussed.

  12. MicroRNA-139 suppresses proliferation in luminal type breast cancer cells by targeting Topoisomerase II alpha

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Wei [Department of Obstetrics and Gynecology, Xijing Hospital, Fourth Military Medical University, Xi' an 710032 (China); State Key Laboratory of Cancer Biology, Department of Biochemistry and Molecular Biology, Fourth Military Medical University, 710032 Xi' an (China); Sa, Ke-Di; Zhang, Xiang; Jia, Lin-Tao; Zhao, Jing [State Key Laboratory of Cancer Biology, Department of Biochemistry and Molecular Biology, Fourth Military Medical University, 710032 Xi' an (China); Yang, An-Gang [State Key Laboratory of Cancer Biology, Department of Immunology, Fourth Military Medical University, 710032 Xi' an (China); Zhang, Rui, E-mail: ruizhang@fmmu.edu.cn [State Key Laboratory of Cancer Biology, Department of Biochemistry and Molecular Biology, Fourth Military Medical University, 710032 Xi' an (China); Fan, Jing, E-mail: jingfan@fmmu.edu.cn [Department of Vascular and Endocrine Surgery, Xijing Hospital, Fourth Military Medical University, Xi' an 710032 (China); Bian, Ka, E-mail: kakamax85@hotmail.com [State Key Laboratory of Cancer Biology, Department of Immunology, Fourth Military Medical University, 710032 Xi' an (China); Department of Otolaryngology, Tangdu Hospital, Fourth Military Medical University, Xi' an 710038 (China)

    2015-08-07

    The classification of molecular subtypes of breast cancer improves the prognostic accuracy and therapeutic benefits in clinic. However, because of the complexity of breast cancer, more biomarkers and functional molecules need to be explored. Here, analyzing the data in a huge cohort of breast cancer patients, we found that Topoisomerase II alpha (TOP2a), an important target of chemotherapy is a biomarker for prognosis in luminal type breast cancer patients, but not in basal like or HER2 positive breast cancer patients. We identified that miR-139, a previous reported anti-metastatic microRNA targets 3’-untranslated region (3′UTR) of TOP2a mRNA. Further more, we revealed that the forced expression of miR-139 reduces the TOP2a expression at both mRNA and protein levels. And our functional experiments showed that the ectopic expression of miR-139 remarkably inhibits proliferation in luminal type breast cancer cells, while exogenous TOP2a expression could rescue inhibition of cell proliferation mediated by miR-139. Collectively, our present study demonstrates the miR-139-TOP2a regulatory axis is important for proliferation in luminal type breast cancer cells. This functional link may help us to further understand the specificity of subtypes of breast cancer and optimize the strategy of cancer treatment. - Highlights: • High levels of TOP2a expression are closely associated with poor prognosis in luminal type breast cancer patients. • TOP2a is a novel target of miR-139. • Overexpression of miR-139 inhibits proliferation in luminal type breast cancer cells. • TOP2a is essential for miR-139-induced growth arrest in luminal type breast cancer cells.

  13. MicroRNA-139 suppresses proliferation in luminal type breast cancer cells by targeting Topoisomerase II alpha

    International Nuclear Information System (INIS)

    Hua, Wei; Sa, Ke-Di; Zhang, Xiang; Jia, Lin-Tao; Zhao, Jing; Yang, An-Gang; Zhang, Rui; Fan, Jing; Bian, Ka

    2015-01-01

    The classification of molecular subtypes of breast cancer improves the prognostic accuracy and therapeutic benefits in clinic. However, because of the complexity of breast cancer, more biomarkers and functional molecules need to be explored. Here, analyzing the data in a huge cohort of breast cancer patients, we found that Topoisomerase II alpha (TOP2a), an important target of chemotherapy is a biomarker for prognosis in luminal type breast cancer patients, but not in basal like or HER2 positive breast cancer patients. We identified that miR-139, a previous reported anti-metastatic microRNA targets 3’-untranslated region (3′UTR) of TOP2a mRNA. Further more, we revealed that the forced expression of miR-139 reduces the TOP2a expression at both mRNA and protein levels. And our functional experiments showed that the ectopic expression of miR-139 remarkably inhibits proliferation in luminal type breast cancer cells, while exogenous TOP2a expression could rescue inhibition of cell proliferation mediated by miR-139. Collectively, our present study demonstrates the miR-139-TOP2a regulatory axis is important for proliferation in luminal type breast cancer cells. This functional link may help us to further understand the specificity of subtypes of breast cancer and optimize the strategy of cancer treatment. - Highlights: • High levels of TOP2a expression are closely associated with poor prognosis in luminal type breast cancer patients. • TOP2a is a novel target of miR-139. • Overexpression of miR-139 inhibits proliferation in luminal type breast cancer cells. • TOP2a is essential for miR-139-induced growth arrest in luminal type breast cancer cells

  14. Recent results with a high-current, heavy-ion source system

    International Nuclear Information System (INIS)

    Keller, R.; Spaedtke, P.; Emig, H.

    1986-01-01

    In the last conference of this series, an improved high-current ion source for gases, CORDIS was presented. This source has been further developed to allow the processing of substances which are not volatile at room temperature. One of these modifications, HORDIS, incorporates an oven whereas the third version works at rather moderate temperatures and can be fed through a slightly heated external bottle. With this source system, high-current ion beams in the 100 mA range can be produced for a considerable part of the periodic table. Operation parameters and experiences with the sources are discussed, and the most recent results for all versions are given. (author)

  15. High-intensity positive beams extracted from a compact double-chamber ion source

    International Nuclear Information System (INIS)

    Huck, H.; Somacal, H.; Di Gregorio, D.E.; Fernandez Niello, J.O.; Igarzabal, M.; Di Paolo, H.; Reinoso, M.

    2005-01-01

    This work presents the design and development of a simple ion source, the associated ion extraction optics, and the beam transport of a low-energy and high-current proton accelerator. In its actual version, the ion source can deliver positive proton currents up to 100 mA. This rather high beam current is achieved by adding a small ionization chamber between the discharge chamber containing the filament and the extraction electrode of the ion source. Different parameters of the ion source and the injection beam line are evaluated by means of computer simulations to optimize the beam production and transmission

  16. Improvement of highly charged ion production in the ECR source of heavy ions

    International Nuclear Information System (INIS)

    Shirkov, G.D.

    1996-01-01

    Some physical limitations of the highly charged ion production in the ECR source are analyzed in this report. A few possible ways to improve the output of highly charged ions from the ECR source for heavy ions are proposed. A new library of computer codes for the numerical simulation of heavy ion production in the ECR ion source is used to examine these ways to improve the ECR source operation according to the CERN program of heavy ion acceleration. copyright 1996 American Institute of Physics

  17. Large-eddy simulation of convective boundary layer generated by highly heated source with open source code, OpenFOAM

    International Nuclear Information System (INIS)

    Hattori, Yasuo; Suto, Hitoshi; Eguchi, Yuzuru; Sano, Tadashi; Shirai, Koji; Ishihara, Shuji

    2011-01-01

    Spatial- and temporal-characteristics of turbulence structures in the close vicinity of a heat source, which is a horizontal upward-facing round plate heated at high temperature, are examined by using well resolved large-eddy simulations. The verification is carried out through the comparison with experiments: the predicted statistics, including the PDF distribution of temperature fluctuations, agree well with measurements, indicating that the present simulations have a capability to appropriately reproduce turbulence structures near the heat source. The reproduced three-dimensional thermal- and fluid-fields in the close vicinity of the heat source reveals developing processes of coherence structures along the surface: the stationary- and streaky-flow patterns appear near the edge, and such patterns randomly shift to cell-like patterns with incursion into the center region, resulting in thermal-plume meandering. Both the patterns have very thin structures, but the depth of streaky structure is considerably small compared with that of cell-like patterns; this discrepancy causes the layered structures. The structure is the source of peculiar turbulence characteristics, the prediction of which is quite difficult with RANS-type turbulence models. The understanding such structures obtained in present study must be helpful to improve the turbulence model used in nuclear engineering. (author)

  18. All solid state high voltage power supply for neutral beam sources

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1984-01-01

    The conceptual design of a high frequency solid state, high power, high voltage, power system that reacts fast enough to be compatible with the requirements of a neutral beam source is presented. The system offers the potential of significant advantages over conventional power line frequency systems; such as high reliability, long life, relatively little maintenance requirements, compact size and modular design

  19. Crystal structure and luminescence properties of (Ca{sub 2.94-x}Lu{sub x}Ce{sub 0.06})(Sc{sub 2-y}Mg{sub y})Si{sub 3}O{sub 12} phosphors for white LEDs with excellent colour rendering and high luminous efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Liu Yongfu; Zhang Xia; Hao Zhendong; Lu Wei; Liu Xingyuan; Zhang Jiahua [Key Laboratory of Excited State Processes, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 3888 Eastern South Lake Road, Changchun 130033 (China); Wang Xiaojun, E-mail: zhangjh@ciomp.ac.cn [Department of Physics, Georgia Southern University, Statesboro, GA 30460 (United States)

    2011-02-23

    Lu-modified (Ca{sub 2.94-x}Lu{sub x}Ce{sub 0.06})(Sc{sub 2-y}Mg{sub y})Si{sub 3}O{sub 12} (CLSMS : Ce{sup 3+}) yellow emitting phosphors are prepared by a solid-state reaction. Controllable luminescent intensity and emitting colour are studied as a function of Lu and Mg contents. Fixing the Mg content to be 1, the effect of Lu content on crystal phase formation, luminescence properties and temperature characteristics is studied. It is revealed that the Lu-induced luminescent enhancement is the result of an increase in absorbance of Ce{sup 3+} rather than the internal quantum efficiency. Intense and broadband emission is realized by controlling the Lu content to obtain a pure CLSMS crystal phase. The maximum luminescence intensity is obtained at x = 0.54, which is as high as 156% of the Lu-free phosphor. The Lu-containing phosphor also exhibits better temperature characteristics for its big activation energy (0.20 eV) than the Lu-free one (0.18 eV). Combining the present phosphor with a blue light-emitting diode (LED) chip, a white LED with an excellent colour rendering index R{sub a} of 86 and a high luminous efficiency of 86 lm W{sup -1} is obtained. The results of the present study demonstrate that the CLSMS : Ce{sup 3+} phosphors show a good performance and are attractive candidates for commercial applications when used in white LEDs.

  20. High brightness K+ ion source for heavy ion fusion linear induction accelerators

    International Nuclear Information System (INIS)

    Henestroza, E.; Eylon, S.; Chupp, W.; Rutkowski, H.

    1992-01-01

    Low emittance, high current, singly charged potassium thermionic ion sources are being developed for the Induction Linac System Experiment injector, ILSE. The ILSE, now in study at LBL, will address the physics issues of particle beams in a heavy ion fusion driver scenario. The K + ion beam considered is emitted thermionically into a diode gap from alumino-silicate layers (zeolite) coated on a porous tungsten cup. The Single Beam Transport Experiment (SBTE) 120keV cesium source was redesigned and modified with the aid of an ion optics and gun design program (EGUN) to enable the evaluation of the K + source performance at high extraction currents of about 80mA from a one inch diameter source. The authors report on the source fabrication technique and performance, including total current and current density profile measurements using Faraday cups, phase space distributions using the double slit scanning technique, and source emitting surface temperature dependence on heating power using a wire pyrometer

  1. THE UNUSUALLY LUMINOUS EXTRAGALACTIC NOVA SN 2010U

    International Nuclear Information System (INIS)

    Czekala, Ian; Berger, E.; Chornock, R.; Marion, G. H.; Margutti, R.; Challis, P.; Pastorello, A.; Botticella, M. T.; Ergon, M.; Sollerman, J.; Smartt, S.; Vinkó, J.; Wheeler, J. C.

    2013-01-01

    We present observations of the unusual optical transient SN 2010U, including spectra taken 1.03 days to 15.3 days after maximum light that identify it as a fast and luminous Fe II type nova. Our multi-band light curve traces the fast decline (t 2 = 3.5 ± 0.3 days) from maximum light (M V = –10.2 ± 0.1 mag), placing SN 2010U in the top 0.5% of the most luminous novae ever observed. We find typical ejecta velocities of ≈1100 km s –1 and that SN 2010U shares many spectral and photometric characteristics with two other fast and luminous Fe II type novae, including Nova LMC 1991 and M31N-2007-11d. For the extreme luminosity of this nova, the maximum magnitude versus rate of decline relationship indicates a massive white dwarf (WD) progenitor with a low pre-outburst accretion rate. However, this prediction is in conflict with emerging theories of nova populations, which predict that luminous novae from massive WDs should preferentially exhibit an alternate spectral type (He/N) near maximum light.

  2. Profile of a Growing Urban School: The Lumin Experience

    Science.gov (United States)

    Ford, Terry

    2015-01-01

    This fairytale-come-true began with an idealistic public school teacher just out of college who lived in the neighborhood of her students. In stages, working with a community organizing group consisting mainly of concerned parents, Terry Ford founded what is now called Lumin Education, a network of campuses serving more than six hundred children…

  3. SN 2010U: A LUMINOUS NOVA IN NGC 4214

    International Nuclear Information System (INIS)

    Humphreys, Roberta M.; Helton, L. Andrew; Prieto, Jose L.; Rosenfield, Philip; Williams, Benjamin; Murphy, Jeremiah; Dalcanton, Julianne; Gilbert, Karoline; Kochanek, Christopher S.; Stanek, K. Z.; Khan, Rubab; Szczygiel, Dorota; Mogren, Karen; Fesen, Robert A.; Milisavljevic, Dan

    2010-01-01

    The luminosity, light curve, post-maximum spectrum, and lack of a progenitor on deep pre-outburst images suggest that SN 2010U was a luminous, fast nova. Its outburst magnitude is consistent with that for a fast nova using the maximum magnitude-rate of decline relationship for classical novae.

  4. Might dark matter not be concentric with luminous matter

    International Nuclear Information System (INIS)

    Xu Chongming; Lu Tan.

    1986-12-01

    In this paper, an idea on dark matter nonconcentric with luminous matter is proposed. This case could influence the rotation curve of galaxy differently in its different direction. Recently, Rubin and Ford's observation on rotation curve of Hickson 88a has been explained by means of the idea. Some possible observational predictions have also been given. (author)

  5. Luminance compensation for AMOLED displays using integrated MIS sensors

    Science.gov (United States)

    Vygranenko, Yuri; Fernandes, Miguel; Louro, Paula; Vieira, Manuela

    2017-05-01

    Active-matrix organic light-emitting diodes (AMOLEDs) are ideal for future TV applications due to their ability to faithfully reproduce real images. However, pixel luminance can be affected by instability of driver TFTs and aging effect in OLEDs. This paper reports on a pixel driver utilizing a metal-insulator-semiconductor (MIS) sensor for luminance control of the OLED element. In the proposed pixel architecture for bottom-emission AMOLEDs, the embedded MIS sensor shares the same layer stack with back-channel etched a Si:H TFTs to maintain the fabrication simplicity. The pixel design for a large-area HD display is presented. The external electronics performs image processing to modify incoming video using correction parameters for each pixel in the backplane, and also sensor data processing to update the correction parameters. The luminance adjusting algorithm is based on realistic models for pixel circuit elements to predict the relation between the programming voltage and OLED luminance. SPICE modeling of the sensing part of the backplane is performed to demonstrate its feasibility. Details on the pixel circuit functionality including the sensing and programming operations are also discussed.

  6. Mechanical feedback in the molecular ISM of luminous IR galaxies

    NARCIS (Netherlands)

    Loenen, A. F.; Spaans, M.; Baan, W. A.; Meijerink, R.

    Aims. Molecular emission lines originating in the nuclei of luminous infra-red galaxies are used to determine the physical properties of the nuclear ISM in these systems. Methods. A large observational database of molecular emission lines is compared with model predictions that include heating by UV

  7. Gastric luminal epidermal growth factor is affected by diet | Iputo ...

    African Journals Online (AJOL)

    Objective. Diet is an area of major interest to those investigating the causes of cancer of the oesophagus in the Transkei. This study looked at the associations between intragastric epidermal growth factor level, diet and intragastric pH. Setting and subjects. A dietary survey was co-ordinated with studies of gastric luminal ...

  8. Vocal Fold Epithelial Response to Luminal Osmotic Perturbation

    Science.gov (United States)

    Sivasankar, Mahalakshmi; Fisher, Kimberly V.

    2007-01-01

    Purpose: Dry-air challenges increase the osmolarity of fluid lining the luminal surface of the proximal airway. The homeostasis of surface fluid is thought to be essential for voice production and laryngeal defense. Therefore, the authors hypothesized that viable vocal fold epithelium would generate a water flux to reduce an osmotic challenge (150…

  9. The predetermination of the luminance in tunnel entrances at day.

    NARCIS (Netherlands)

    Schreuder, D.A. & Oud, H.J.C.

    1988-01-01

    In tunnel lighting practice, only the scatter in the eye, in the windscreen of the car, and in the atmosphere need to be taken into account. For all practical day- time conditions, the required luminance in any portion of the tunnel can be assessed as being a constant fraction of this sum-

  10. Increasing the luminous efficiency of an MEH-PPV based PLED using salmon DNA and single walled carbon nanotube

    International Nuclear Information System (INIS)

    Madhwal, Devinder; Singh, Inderpreet; Kumar, Jitender; Bhatia, C.S.; Bhatnagar, P.K.; Mathur, P.C.

    2011-01-01

    The combined effect of a salmon deoxyribonucleic acid (DNA)-based electron blocking layer and a single walled carbon nanotube (SWCNT) composite-based electron transport layer on the performance of a poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV) polymer light emitting diode (PLED) has been examined. The SWCNT network in the composite layer improves electron injection from cathode and the DNA blocks these high mobility electrons at the electron blocking layer-polymer interface, leading to high luminance from the device. The luminous efficiency of the PLED is increased ∼20 times compared to that of a PLED using only MEH-PPV. - Highlights: → We report fabrication of a high luminous efficiency MEH-PPV based polymer LED. → Salmon DNA-CTMA layer is used to block injected electrons in the polymer layer. → MEH-PPV-SWCNT composite is used to transport electrons in the polymer layer. → The luminous efficiency of the polymer LED thereby improves about 20 times.

  11. Point source search techniques in ultra high energy gamma ray astronomy

    International Nuclear Information System (INIS)

    Alexandreas, D.E.; Biller, S.; Dion, G.M.; Lu, X.Q.; Yodh, G.B.; Berley, D.; Goodman, J.A.; Haines, T.J.; Hoffman, C.M.; Horch, E.; Sinnis, C.; Zhang, W.

    1993-01-01

    Searches for point astrophysical sources of ultra high energy (UHE) gamma rays are plagued by large numbers of background events from isotropic cosmic rays. Some of the methods that have been used to estimate the expected number of background events coming from the direction of a possible source are found to contain biases. Search techniques that avoid this problem are described. There is also a discussion of how to optimize the sensitivity of a search to emission from a point source. (orig.)

  12. A high charge state heavy ion beam source for heavy ion fusion

    International Nuclear Information System (INIS)

    Eylon, S.; Henestroza, E.

    1996-01-01

    A high current, low emittance, high charge state heavy ion beam source is being developed. This is designed to deliver a heavy ion fusion (HIF) driver accelerator scale beam. Using a high charge state beam in a driver accelerator for HIF may increase the acceleration efficiency, leading to a reduction in the driver accelerator size and cost. The proposed source system, which consists of a gas beam electron stripper followed by a high charge state beam separator, can be added to existing single charge state, low emittance, high brightness ion sources and injectors. We shall report on the source physics design using 3D beam simulations and experimental feasibility study results using a neutral gas stripper and a beam separator at the exit of the LBL 2 MV injector. (orig.)

  13. A strategy to unveil transient sources of ultra-high-energy cosmic rays

    Directory of Open Access Journals (Sweden)

    Takami Hajime

    2013-06-01

    Full Text Available Transient generation of ultra-high-energy cosmic rays (UHECRs has been motivated from promising candidates of UHECR sources such as gamma-ray bursts, flares of active galactic nuclei, and newly born neutron stars and magnetars. Here we propose a strategy to unveil transient sources of UHECRs from UHECR experiments. We demonstrate that the rate of UHECR bursts and/or flares is related to the apparent number density of UHECR sources, which is the number density estimated on the assumption of steady sources, and the time-profile spread of the bursts produced by cosmic magnetic fields. The apparent number density strongly depends on UHECR energies under a given rate of the bursts, which becomes observational evidence of transient sources. It is saturated at the number density of host galaxies of UHECR sources. We also derive constraints on the UHECR burst rate and/or energy budget of UHECRs per source as a function of the apparent source number density by using models of cosmic magnetic fields. In order to obtain a precise constraint of the UHECR burst rate, high event statistics above ∼ 1020 eV for evaluating the apparent source number density at the highest energies and better knowledge on cosmic magnetic fields by future observations and/or simulations to better estimate the time-profile spread of UHECR bursts are required. The estimated rate allows us to constrain transient UHECR sources by being compared with the occurrence rates of known energetic transient phenomena.

  14. High stabilized power sources for bending and quadrupole magnets of TRISTAN project

    International Nuclear Information System (INIS)

    Kumagai, Noritaka; Ogawa, Shin-ichi; Koseki, Shoichiro; Nagasaka, Saburo.

    1984-01-01

    In the power source exciting the electro-magnets for the electron ring of TRISTAN project being advanced in the National Laboratory for High Energy Physics, the performance as strict as 10 -4 is required for its long hour stability and pulsating rate of DC output current in order to maintain beam stably. For satisfying such specification, the structure of power source using a high accuracy current detector, an active filter and so on was adopted. In order to verify the performance of this power source, the trial manufacture was carried out independently, and the test combining with actual magnets was performed. As the results, it was confirmed that the power source had the sufficient performance about its output stability, pulsating rate, current-following property and so on. At present, the manufacture of 80 actual power sources is in progress. In this paper, the power source system and the results of performance test of the power source made for trial are reported. The power sources are divide into B power sources for exciting deflecting electro-magnets and Q power sources for exciting quadrupole electro-magnets. (Kako, I.)

  15. Investigations on a highly luminous condensed xenon scintillator

    International Nuclear Information System (INIS)

    Lansiart, Alain; Seigneur, Alain; Morucci, J.-P.

    1976-12-01

    The means of creating a maximal amount of light by absorption of gamma radiation in condensed xenon were investigated. One of the methods relies on the light production around wires in liquid xenon when several kilovolts are applied to them. Another method uses the saturating vapor present over solid xenon; the electric field pulls out electrons from the solid and accelerates them in the gas phase where they produce light through inelastic collisions [fr

  16. Sources of Writing Self-Efficacy Beliefs of Elementary, Middle, and High School Students

    Science.gov (United States)

    Pajares, Frank; Johnson, Margaret J.; Usher, Ellen L.

    2007-01-01

    The purpose of this study was to examine the influence of Albert Bandura's four hypothesized sources of self-efficacy on students' writing self-efficacy beliefs (N = 1256) and to explore how these sources differ as a function of gender and academic level (elementary, middle, high). Consistent with the tenets of self-efficacy theory, each of the…

  17. Techniques and mechanisms applied in electron cyclotron resonance sources for highly charged ions

    NARCIS (Netherlands)

    Drentje, AG

    Electron cyclotron resonance ion sources are delivering beams of highly charged ions for a wide range of applications in many laboratories. For more than two decades, the development of these ion sources has been to a large extent an intuitive and experimental enterprise. Much effort has been spent

  18. Preferred Information Sources of High School Students for Community Colleges and Universities

    Science.gov (United States)

    Goff, Brent; Patino, Vanessa; Jackson, Gary

    2004-01-01

    To effectively communicate with potential students, it is important to utilize their preferred information sources. Survey data were gathered from 716 high school students who planned to attend college. There were communication source differences based on race and intent to attend two-year vs. four-year institutions. Important information sources…

  19. A 1.5 GeV high brilliance synchrotron light source with combined function lattice

    International Nuclear Information System (INIS)

    Eriksson, M.; Lindgren, L.J.; Andersson, Aa.; Roejsel, P.; Werin, S.

    1988-01-01

    A 1.5 GeV synchrotron light source with a combined function lattice is studied. The light source will offer X-ray radiation with λc=1.0 angstrom from a superconducting wiggler and high brilliance VUV-radiation from undulators. The magnet lattice, magnet design and ring performance is discussed. (authors)

  20. Short Pulse High Brightness X-ray Production with the PLEIADES Thomson Scattering Source

    International Nuclear Information System (INIS)

    Anderson, S.G.; Barty, C.P.J.; Betts, S.M.; Brown, W.J.; Crane, J.K.; Cross, R.R.; Fittinghoff, D.N.; Gibson, D.J.; Hartemann, F.V.; Kuba, J.; LaSage, G.P.; Rosenzweig, J.B.; Slaughter, D.R.; Springer, P.T.; Tremaine, A.M.

    2003-01-01

    We describe PLEIADES, a compact, tunable, high-brightness, ultra-short pulse, Thomson x-ray source. The peak brightness of the source is expected to exceed 10 20 photons/s/0.1% bandwidth/mm 2 /mrad 2 . Initial results are reported and compared to theoretical calculations

  1. EVIDENCE FOR SIMULTANEOUS JETS AND DISK WINDS IN LUMINOUS LOW-MASS X-RAY BINARIES

    Energy Technology Data Exchange (ETDEWEB)

    Homan, Jeroen; Neilsen, Joseph; Allen, Jessamyn L.; Chakrabarty, Deepto; Remillard, Ronald A.; Schulz, Norbert [MIT Kavli Institute for Astrophysics and Space Research, 77 Massachusetts Avenue 37-582D, Cambridge, MA 02139 (United States); Fender, Rob [Astrophysics, Department of Physics, University of Oxford, Keble Road, Oxford OX1 3RH (United Kingdom); Fridriksson, Joel K., E-mail: jeroen@space.mit.edu [Anton Pannekoek Institute, University of Amsterdam, Postbus 94249, 1090 GE Amsterdam (Netherlands)

    2016-10-10

    Recent work on jets and disk winds in low-mass X-ray binaries (LMXBs) suggests that they are to a large extent mutually exclusive, with jets observed in spectrally hard states and disk winds observed in spectrally soft states. In this paper we use existing literature on jets and disk winds in the luminous neutron star (NS) LMXB GX 13+1, in combination with archival Rossi X-ray Timing Explorer data, to show that this source is likely able to produce jets and disk winds simultaneously. We find that jets and disk winds occur in the same location on the source’s track in its X-ray color–color diagram. A further study of literature on other luminous LMXBs reveals that this behavior is more common, with indications for simultaneous jets and disk winds in the black hole LMXBs V404 Cyg and GRS 1915+105 and the NS LMXBs Sco X-1 and Cir X-1. For the three sources for which we have the necessary spectral information, we find that simultaneous jets/winds all occur in their spectrally hardest states. Our findings indicate that in LMXBs with luminosities above a few tens of percent of the Eddington luminosity, jets and disk winds are not mutually exclusive, and the presence of disk winds does not necessarily result in jet suppression.

  2. Effects of Irradiation on bacterial atp luminous intensity of cooled pork and chicken

    International Nuclear Information System (INIS)

    Ju Hua

    2010-01-01

    The effect of irradiation on cooled pork and chicken was detected with ATP luminous intensity method. The influences of other factors to ATP luminous intensity were also discussed. There was positive correlation between ATP standard concentration and ATP luminous intensity, and negative correlation between irradiation dosage and ATP luminous intensity. The trend of ATP luminous intensity of cooled pork and chicken after irradiation was inverse S, and the maximum ATP luminous intensity appeared at 6.0 kGy, and minimum at 4.0 and 8.0 kGy. Sterilized water and sterilized pork had no interference to ATP luminous intensity of the samples. There was significant positive correlation between E. coli 10003 concentration and ATP luminous intensity, the coefficient correlation was 0.9437. (authors)

  3. Development of the High Current Ion Source for Neutral Beam Injection

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hun Ju; Kim, S. H.; Jang, D. H. [Jae Ju University, Jaeju (Korea, Republic of)

    1997-08-01

    The scope of the 1st year research is to design an 140keV deuterium ion source which has a beam current of 30-40A. According to the collected data, the model of an ion source for NBI of KSTAR was established. The negative ion source, which has good neutralization effecting in high energy, was selected. To generate a plasma, the thoriated tungsten filament was adopted. To increase the efficiency of plasma, the multi cusp type magnetic field was attached. The magnetic field was calculated by POISSON code. The extraction structure was designed with EGUN code, to extract the high quality ion beam. The design of a high current ion source for NBI was carried out. To develop the high current ion source with the high operational stability and the long lifetime, the parameters including an arc current, gas pressure and extraction voltage should be optimized. If designed ion source would be fabricated, its parameters could be optimized experimentally. Through the optimization of the ion source parameter, the core technology for NBI is established and the experiment of current drive in the fusion device can be performed. This technology also can be applied to the synthesis of new material and semiconductor industry. 18 refs., 11 tabs., 19 figs. (author)

  4. High-resolution and super stacking of time-reversal mirrors in locating seismic sources

    KAUST Repository

    Cao, Weiping; Hanafy, Sherif M.; Schuster, Gerard T.; Zhan, Ge; Boonyasiriwat, Chaiwoot

    2011-01-01

    Time reversal mirrors can be used to backpropagate and refocus incident wavefields to their actual source location, with the subsequent benefits of imaging with high-resolution and super-stacking properties. These benefits of time reversal mirrors

  5. ESA Gaia & the multifrequency behavior of high-energy sources with ultra-low dispersion spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Hudec, René; Šimon, Vojtěch; Hudec, L.; Hudcová, Věra

    2012-01-01

    Roč. 83, č. 1 (2012), s. 342-346 ISSN 0037-8720. [Workshop on multifrequency behaviour of high energy cosmic sources. Vulcano, 23.05.2011-28.05.2011] R&D Projects: GA ČR GA205/08/1207 Institutional research plan: CEZ:AV0Z10030501 Keywords : X-rays * high-energy sources * satellites Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  6. A new coaxial high power microwave source based on dual beams

    International Nuclear Information System (INIS)

    Li, Yangmei; Zhang, Xiaoping; Qi, Zumin; Dang, Fangchao; Qian, Baoliang

    2014-01-01

    We present a new coaxial high power microwave source based on dual beams, which combines a relativistic backward wave oscillator (RBWO) (noted as the inner sub-source below) and a coaxial transit-time oscillator (TTO) (noted as the outer sub-source). The cathode consists of an inner and an outer annular cathode, which provides the inner and the outer annular electron beam for the sub-sources, respectively. Particle-in-cell (PIC) simulation results demonstrate that power conversion efficiencies of the two sub-sources with an identical frequency of 9.74 GHz are 29% and 25%, respectively. It is furthermore found that phase locking between the inner and the outer sub-sources can be realized, which suggests a feasibility to obtain a higher power output if the two microwave signals are coherently combined

  7. A new coaxial high power microwave source based on dual beams

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yangmei, E-mail: sunberry1211@hotmail.com; Zhang, Xiaoping; Qi, Zumin; Dang, Fangchao; Qian, Baoliang [College of Optoelectric Science and Engineering, National University of Defense Technology, Changsha 410073 (China)

    2014-05-15

    We present a new coaxial high power microwave source based on dual beams, which combines a relativistic backward wave oscillator (RBWO) (noted as the inner sub-source below) and a coaxial transit-time oscillator (TTO) (noted as the outer sub-source). The cathode consists of an inner and an outer annular cathode, which provides the inner and the outer annular electron beam for the sub-sources, respectively. Particle-in-cell (PIC) simulation results demonstrate that power conversion efficiencies of the two sub-sources with an identical frequency of 9.74 GHz are 29% and 25%, respectively. It is furthermore found that phase locking between the inner and the outer sub-sources can be realized, which suggests a feasibility to obtain a higher power output if the two microwave signals are coherently combined.

  8. THE HOST GALAXY OF THE SUPER-LUMINOUS SN 2010gx AND LIMITS ON EXPLOSIVE 56Ni PRODUCTION

    International Nuclear Information System (INIS)

    Chen, Ting-Wan; Smartt, Stephen J.; Kotak, Rubina; McCrum, Matt; Fraser, Morgan; Bresolin, Fabio; Kudritzki, Rolf-Peter; Pastorello, Andrea; Valenti, Stefano

    2013-01-01

    Super-luminous supernovae have a tendency to occur in faint host galaxies which are likely to have low mass and low metallicity. While these extremely luminous explosions have been observed from z = 0.1 to 1.55, the closest explosions allow more detailed investigations of their host galaxies. We present a detailed analysis of the host galaxy of SN 2010gx (z = 0.23), one of the best studied super-luminous type Ic supernovae. The host is a dwarf galaxy (M g = –17.42 ± 0.17) with a high specific star formation rate. It has a remarkably low metallicity of 12 + log (O/H) = 7.5 ± 0.1 dex as determined from the detection of the [O III] λ4363 line. This is the first reliable metallicity determination of a super-luminous stripped-envelope supernova host. We collected deep multi-epoch imaging with Gemini + GMOS between 240 and 560 days after explosion to search for any sign of radioactive 56 Ni, which might provide further insights on the explosion mechanism and the progenitor's nature. We reach griz magnitudes of m AB ∼ 26, but do not detect SN 2010gx at these epochs. The limit implies that any 56 Ni production was similar to or below that of SN 1998bw (a luminous type Ic SN that produced around 0.4 M ☉ of 56 Ni). The low volumetric rates of these supernovae (∼10 –4 of the core-collapse population) could be qualitatively matched if the explosion mechanism requires a combination of low-metallicity (below 0.2 Z ☉ ), high progenitor mass (>60 M ☉ ) and high rotation rate (fastest 10% of rotators).

  9. OSO-7 observations of high galactic latitude x-ray sources

    International Nuclear Information System (INIS)

    Markert, T.H.; Canizares, C.R.; Clark, G.W.; Li, F.K.; Northridge, P.L.; Sprott, G.F.; Wargo, G.F.

    1976-01-01

    Six hundred days of observations by the MIT X-ray detectors aboard OSO-7 have been analyzed. All-sky maps of X-ray intensity have been constructed from these data. A sample map is displayed. Seven sources with galactic latitude vertical-barb/subi//subi/vertical-bar>10degree, discovered during the mapping process, are reported, and upper limits are set on other high-latitude sources. The OSO-7 results are compared with those of Uhuru and an implication of this comparison, that many of the high-latitude sources may be variable, is discussed

  10. File list: His.Brs.10.AllAg.Luminal_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Brs.10.AllAg.Luminal_cells mm9 Histone Breast Luminal cells SRX213395,SRX213418...,SRX213416 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Brs.10.AllAg.Luminal_cells.bed ...

  11. File list: ALL.Brs.10.AllAg.Luminal_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Brs.10.AllAg.Luminal_cells mm9 All antigens Breast Luminal cells SRX213395,SRX2...13418,SRX213398,SRX213416 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Brs.10.AllAg.Luminal_cells.bed ...

  12. File list: ALL.Brs.50.AllAg.Luminal_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Brs.50.AllAg.Luminal_cells mm9 All antigens Breast Luminal cells SRX213395,SRX2...13418,SRX213398,SRX213416 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Brs.50.AllAg.Luminal_cells.bed ...

  13. File list: His.Brs.05.AllAg.Luminal_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Brs.05.AllAg.Luminal_cells mm9 Histone Breast Luminal cells SRX213395,SRX213418...,SRX213416 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Brs.05.AllAg.Luminal_cells.bed ...

  14. File list: His.Brs.50.AllAg.Luminal_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Brs.50.AllAg.Luminal_cells mm9 Histone Breast Luminal cells SRX213395,SRX213418...,SRX213416 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Brs.50.AllAg.Luminal_cells.bed ...

  15. File list: ALL.Brs.20.AllAg.Luminal_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Brs.20.AllAg.Luminal_cells mm9 All antigens Breast Luminal cells SRX213395,SRX2...13418,SRX213398,SRX213416 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Brs.20.AllAg.Luminal_cells.bed ...

  16. Radiation exposure to dial painters from 3H luminous paint industry

    International Nuclear Information System (INIS)

    Sawant, J.V.

    1992-01-01

    Tritium is used as the active component in self-luminous paint. The paper describes in-vitro solubilisation study of luminous paint in blood serum. Besides urine samples of luminous paint workers and air samples of two watch factories were analysed for 3 H. The results of these analysis are also presented. (author). 8 refs., 4 figs., 4 tabs

  17. Conjunctions of colour, luminance and orientation: the role of colour and luminance contrast on saliency and proximity grouping in texture segregation.

    Science.gov (United States)

    Leonards, U; Singer, W

    2000-01-01

    To examine whether perceptual grouping on the basis of orientation can be performed simultaneously with or only subsequently to grouping according to colour or luminance, we tested whether subjects are able to segregate arrays of texture elements that differ from surrounding elements by conjunctions of either (i) colour and orientation, or (ii) luminance contrast and orientation, or (iii) luminance contrast polarity and orientation. Subjects were able to use conjunctions between luminance and orientation for segregation but not conjunctions between colour or contrast polarity and orientation. Our results suggest that (i) in agreement with earlier findings, there seem to exist no specific conjunction detectors for colour and orientation or contrast polarity and orientation, and (ii) when orientation defined textures are to be distinguished by virtue of differences in luminance, colour, or contrast polarity, luminance provides a much stronger cue than colour or contrast polarity for saliency-based orientation grouping.

  18. Seasonal and geographic distribution of luminous bacteria in the eastern mediterranean sea and the gulf of elat.

    Science.gov (United States)

    Yetinson, T; Shilo, M

    1979-06-01

    Luminous bacteria in the Mediterranean Sea and the Gulf of Aqaba-Elat have different distribution patterns. In the Mediterranean Sea, Beneckea harveyi is present all year round, with different subtypes alternating in summer and winter; Photobacterium fischeri was only present during the winter. In the Gulf of Elat, P. leiognathi is present throughout the water column in similar densities during the entire year. This constancy in distribution is presumably due to the near-constancy in water temperature. In summer, Photobacterium leiognathi is replaced by B. harveyi in coastal surface waters. In the hypersaline Bardawil lagoon, only B. harveyi types are present. P. fischeri, a major component of the Mediterranean Sea winter communities, is absent from the lagoon. Luminous Beneckea strains show a great diversity in properties, e.g. temperature range for growth, sensitivity to infection by phages, sensitivity to attack by Bdellovibrio strains, and differences in tolerance to high-salinity shock. Therefore, subdivision of the taxonomic cluster of B. harveyi into subtypes is indicated. The composition of the luminous bacteria communities may serve as indicators of different marine water bodies. The symbiotic luminous bacteria of the light organ of the common Gulf of Elat fish, Photoblepharon palbebratus steinitzi, is different from any of the types described.

  19. Rate-adaptive BCH coding for Slepian-Wolf coding of highly correlated sources

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Salmistraro, Matteo; Larsen, Knud J.

    2012-01-01

    This paper considers using BCH codes for distributed source coding using feedback. The focus is on coding using short block lengths for a binary source, X, having a high correlation between each symbol to be coded and a side information, Y, such that the marginal probability of each symbol, Xi in X......, given Y is highly skewed. In the analysis, noiseless feedback and noiseless communication are assumed. A rate-adaptive BCH code is presented and applied to distributed source coding. Simulation results for a fixed error probability show that rate-adaptive BCH achieves better performance than LDPCA (Low......-Density Parity-Check Accumulate) codes for high correlation between source symbols and the side information....

  20. Surgery for luminal Crohn’s disease

    Science.gov (United States)

    Yamamoto, Takayuki; Watanabe, Toshiaki

    2014-01-01

    Many patients with Crohn’s disease (CD) require surgery. Indications for surgery include failure of medical treatment, bowel obstruction, fistula or abscess formation. The most common surgical procedure is resection. In jejunoileal CD, strictureplasty is an accepted surgical technique that relieves the obstructive symptoms, while preserving intestinal length and avoiding the development of short bowel syndrome. However, the role of strictureplasty in duodenal and colonic diseases remains controversial. In extensive colitis, after total colectomy with ileorectal anastomosis (IRA), the recurrence rates and functional outcomes are reasonable. For patients with extensive colitis and rectal involvement, total colectomy and end-ileostomy is safe and effective; however, a few patients can have subsequent IRA, and half of the patients will require proctectomy later. Proctocolectomy is associated with a high incidence of delayed perineal wound healing, but it carries a low recurrence rate. Patients undergoing proctocolectomy with ileal pouch-anal anastomosis had poor functional outcomes and high failure rates. Laparoscopic surgery has been introduced as a minimal invasive procedure. Patients who undergo laparoscopic surgery have a more rapid recovery of bowel function and a shorter hospital stay. The morbidity also is lower, and the rate of disease recurrence is similar compared with open procedures. PMID:24415860

  1. Management of disused high-activity sealed radioactive sources: Opting for removal from the national territory

    Energy Technology Data Exchange (ETDEWEB)

    Mourão, Rogério Pimenta, E-mail: mouraor@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Since 2007 Brazil has been using the removal from its territory as a strategy for the management of sealed sources. Three campaigns have been carried out so far, each aiming at specific source types or categories. In the first of these campaigns in 2007, 126 neutron sources of American origin were repatriated to the USA, followed in 2010 by around 900 low activity sources (Categories 3 to 5, according to the IAEA classification system). Both operations were conducted by teams of the American institute Los Alamos National Laboratory. A third campaign, focused on high activity sources – essentially Cobalt-60 sources for teletherapy – was carried out between 2016 and 2017 and resulted in 81 spent high activity radioactive sources of American- and Canadian-origin been sent to Germany and the USA. This operation was carried out by a team of South Africa using a dedicated Mobile Hot Cell. The benefits to Brazil resulting from these operations are clear: increase in safety and security; availability of new precious storage space; less effort dedicated to the disused sealed sources storage; less space in the future borehole facility; financial gains in the selling or reuse of steel, lead and depleted uranium from the original shields. An overexposure incident occurred during the operation, in which a worker was exposed to a dose above the annual statutory limit. (author)

  2. Calibration procedure for thermoluminescent dosemeters in water absorbed doses for Iridium-192 high dose rate sources

    International Nuclear Information System (INIS)

    Reyes Cac, Franky Eduardo

    2004-10-01

    Thermoluminescent dosimeters are used in brachytherapy services quality assurance programs, with the aim of guaranteeing the correct radiation dose supplied to cancer patients, as well as with the purpose of evaluating new clinical procedures. This work describes a methodology for thermoluminescent dosimeters calibration in terms of absorbed dose to water for 192 Ir high dose rate sources. The reference dose used is measured with an ionization chamber previously calibrated for 192 Ir energy quality, applying the methodology proposed by Toelli. This methodology aims to standardizing the procedure, in a similar form to that used for external radiotherapy. The work evolves the adaptation of the TRS-277 Code of the International Atomic Energy Agency, for small and big cavities, through the introduction for non-uniform experimental factor, for the absorbed dose in the neighborhood of small brachytherapy sources. In order to simulate a water medium around the source during the experimental work, an acrylic phantom was used. It guarantees the reproducibility of the ionization chamber and the thermoluminescent dosimeter's location in relation to the radiation source. The values obtained with the ionization chamber and the thermoluminescent dosimeters, exposed to a 192 Ir high dose rate source, were compared and correction factors for different source-detector distances were determined for the thermoluminescent dosimeters. A numeric function was generated relating the correction factors and the source-detector distance. These correction factors are in fact the thermoluminescent dosimeter calibration factors for the 192 Ir source considered. As a possible application of this calibration methodology for thermoluminescent dosimeters, a practical range of source-detector distances is proposed for quality control of 192 Ir high dose rate sources. (author)

  3. Discovery of a point-like very-high-energy gamma-ray source in Monoceros

    International Nuclear Information System (INIS)

    Aharonian, F.A.; Benbow, W.; Berge, D.; Bernlohr, K.; Bolz, O.; Braun, I.; Buhler, R.; Carrigan, S.; Costamante, L.; Domainko, W.; Egberts, K.; Forster, A.; Funk, S.; Hauser, D.; Hermann, G.; Hinton, J.A.; Hofmann, W.; Hoppe, S.; Khelifi, B.; Kosack, K.; Masterson, C.; Panter, M.; Rowell, G.; van Eldik, C.; Volk, H.J.; Akhperjanian, A.G.; Sahakian, V.; Bazer-Bachi, A.R.; Borrel, V.; Marcowith, A.; Olive, J.P.; Beilicke, M.; Cornils, R.; Heinzelmann, G.; Raue, M.; Ripken, J.; Bernlohr, K.; Funk, Seb.; Fussling, M.; Kerschhaggl, M.; Lohse, T.; Schlenker, S.; Schwanke, U.; Boisson, C.; Martin, J.M.; Sol, H.; Brion, E.; Glicenstein, J.F.; Goret, P.; Moulin, E.; Rolland, L.

    2007-01-01

    Aims. The complex Monoceros Loop SNR/Rosette Nebula region contains several potential sources of very-high-energy (VHE) γ-ray emission and two as yet unidentified high-energy EGRET sources. Sensitive VHE observations are required to probe acceleration processes in this region. Methods. The HESS telescope array has been used to search for very high-energy gamma-ray sources in this region. CO data from the NANTEN telescope were used to map the molecular clouds in the region, which could act as target material for γ-ray production via hadronic interactions. Results. We announce the discovery of a new γ-ray source, HESS J0632+057, located close to the rim of the Monoceros SNR. This source is unresolved by HESS and has no clear counterpart at other wavelengths but is possibly associated with the weak X-ray source 1RXS J063258.3+054857, the Be-star MWC148 and/or the lower energy γ-ray source 3EGJ0634+0521. No evidence for an associated molecular cloud was found in the CO data. (authors)

  4. Non-uniform dwell times in line source high dose rate brachytherapy: physical and radiobiological considerations

    International Nuclear Information System (INIS)

    Jones, B.; Tan, L.T.; Freestone, G.; Bleasdale, C.; Myint, S.; Littler, J.

    1994-01-01

    The ability to vary source dwell times in high dose rate (HDR) brachytherapy allows for the use of non-uniform dwell times along a line source. This may have advantages in the radical treatment of tumours depending on individual tumour geometry. This study investigates the potential improvements in local tumour control relative to adjacent normal tissue isoeffects when intratumour source dwell times are increased along the central portion of a line source (technique A) in radiotherapy schedules which include a relatively small component of HDR brachytherapy. Such a technique is predicted to increase the local control for tumours of diameters ranging between 2 cm and 4 cm by up to 11% compared with a technique in which there are uniform dwell times along the line source (technique B). There is no difference in the local control rates for the two techniques when used to treat smaller tumours. Normal tissue doses are also modified by the technique used. Technique A produces higher normal tissue doses at points perpendicular to the centre of the line source and lower dose at points nearer the ends of the line source if the prescription point is not in the central plane of the line source. Alternatively, if the dose is prescribed at a point in the central plane of the line source, the dose at all the normal tissue points are lower when technique A is used. (author)

  5. Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology

    Science.gov (United States)

    Rawat, R. S.

    2015-03-01

    The dense plasma focus (DPF), a coaxial plasma gun, utilizes pulsed high current electrical discharge to heat and compress the plasma to very high density and temperature with energy densities in the range of 1-10 × 1010 J/m3. The DPF device has always been in the company of several alternative magnetic fusion devices as it produces intense fusion neutrons. Several experiments conducted on many different DPF devices ranging over several order of storage energy have demonstrated that at higher storage energy the neutron production does not follow I4 scaling laws and deteriorate significantly raising concern about the device's capability and relevance for fusion energy. On the other hand, the high energy density pinch plasma in DPF device makes it a multiple radiation source of ions, electron, soft and hard x-rays, and neutrons, making it useful for several applications in many different fields such as lithography, radiography, imaging, activation analysis, radioisotopes production etc. Being a source of hot dense plasma, strong shockwave, intense energetic beams and radiation, etc, the DPF device, additionally, shows tremendous potential for applications in plasma nanoscience and plasma nanotechnology. In the present paper, the key features of plasma focus device are critically discussed to understand the novelties and opportunities that this device offers in processing and synthesis of nanophase materials using, both, the top-down and bottom-up approach. The results of recent key experimental investigations performed on (i) the processing and modification of bulk target substrates for phase change, surface reconstruction and nanostructurization, (ii) the nanostructurization of PLD grown magnetic thin films, and (iii) direct synthesis of nanostructured (nanowire, nanosheets and nanoflowers) materials using anode target material ablation, ablated plasma and background reactive gas based synthesis and purely gas phase synthesis of various different types of

  6. Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology

    International Nuclear Information System (INIS)

    Rawat, R S

    2015-01-01

    The dense plasma focus (DPF), a coaxial plasma gun, utilizes pulsed high current electrical discharge to heat and compress the plasma to very high density and temperature with energy densities in the range of 1-10 × 10 10 J/m 3 . The DPF device has always been in the company of several alternative magnetic fusion devices as it produces intense fusion neutrons. Several experiments conducted on many different DPF devices ranging over several order of storage energy have demonstrated that at higher storage energy the neutron production does not follow I 4 scaling laws and deteriorate significantly raising concern about the device's capability and relevance for fusion energy. On the other hand, the high energy density pinch plasma in DPF device makes it a multiple radiation source of ions, electron, soft and hard x-rays, and neutrons, making it useful for several applications in many different fields such as lithography, radiography, imaging, activation analysis, radioisotopes production etc. Being a source of hot dense plasma, strong shockwave, intense energetic beams and radiation, etc, the DPF device, additionally, shows tremendous potential for applications in plasma nanoscience and plasma nanotechnology. In the present paper, the key features of plasma focus device are critically discussed to understand the novelties and opportunities that this device offers in processing and synthesis of nanophase materials using, both, the top-down and bottom-up approach. The results of recent key experimental investigations performed on (i) the processing and modification of bulk target substrates for phase change, surface reconstruction and nanostructurization, (ii) the nanostructurization of PLD grown magnetic thin films, and (iii) direct synthesis of nanostructured (nanowire, nanosheets and nanoflowers) materials using anode target material ablation, ablated plasma and background reactive gas based synthesis and purely gas phase synthesis of various different types of

  7. Spatiotemporal Characteristics for the Depth from Luminance Contrast

    Directory of Open Access Journals (Sweden)

    Kazuya Matsubara

    2011-05-01

    Full Text Available Images with higher luminance contrast tend to be perceived closer in depth. To investigate a spatiotemporal characteristic of this effect, we evaluated subjective depth of a test stimulus with various spatial and temporal frequencies. For the purpose, the depth of a reference stimulus was matched to that of the test stimulus by changing the binocular disparity. The results showed that the test stimulus was perceived closer with higher luminance contrast for all conditions. Contrast efficiency was obtained from the contrast that provided the subjective depth for each spatiotemporal frequency. The shape of the contrast efficiency function was spatially low-pass and temporally band-pass. This characteristic is different from the one measure for a detection task. This suggests that only subset of contrast signals are used for depth from contrast.

  8. Development and construction of a programmable generator of luminous impulses

    International Nuclear Information System (INIS)

    Sahuc, P.

    1989-01-01

    The design and construction of an impulse generator, for light waves, designed to control the characteristics of a scintillator. In these detectors, a particle gives rise to the emission of a luminous signal, which must be transformed in an electrical signal. In the present work, photomultipliers are used as luminous-electrical signal converters. The principles of operation of a scintillator, of a scintillator connected with a photodiode, and of a scintillator connected with a photomultiplier are reviewed. The analysis of the performance and of the possibilies offered by the usual generators of light, show that more suitable solutions are required. The characteristics of the electroluminescent diodes, their performances, concerning light emission and power, are investigated. The principles, the operating conditions and the performances of a generator of light, applying electroluminescent diodes, are examined. The construction and the results obtained with a prototype are presented [fr

  9. Virulence of luminous vibrios to Artemia franciscana nauplii.

    Science.gov (United States)

    Soto-Rodriguez, S A; Roque, A; Lizarraga-Partida, M L; Guerra-Flores, A L; Gomez-Gill, B

    2003-02-27

    From healthy and diseased penaeid shrimp from Asia and the Americas, 25 luminous and 2 non-luminous bacterial strains were isolated, and 14 were phenotypically identified as Vibrio harveyi; 9 isolates produced significant mortalities (45 to 80%) in Artemia franciscana nauplii at inoculation densities of 10(5) to 10(6) CFU ml(-1) compared to the controls (unchallenged nauplii). The maximum number of bacteria ingested (bioencapsulated) by the Artemia nauplii varied from less than 10 to 10(3) CFU nauplius(-1) and no significant relationship was observed between the density of bacteria inoculated, the amount of bacteria ingested, and naupliar mortality. Significant correlations were obtained between naupliar mortality and production of proteases, phospholipases or siderophores, but not between mortality and lipase production, gelatinase production, hydrophobicity or hemolytic activity. The results suggest that virulence of the strains tested was more related to the production of particular exoenzymes than to the measured colonization factors.

  10. An evaluation of organic light emitting diode monitors for medical applications: great timing, but luminance artifacts.

    Science.gov (United States)

    Elze, Tobias; Taylor, Christopher; Bex, Peter J

    2013-09-01

    In contrast to the dominant medical liquid crystal display (LCD) technology, organic light-emitting diode (OLED) monitors control the display luminance via separate light-emitting diodes for each pixel and are therefore supposed to overcome many previously documented temporal artifacts of medical LCDs. We assessed the temporal and luminance characteristics of the only currently available OLED monitor designed for use in the medical treatment field (SONY PVM2551MD) and checked the authors' main findings with another SONY OLED device (PVM2541). Temporal properties of the photometric output were measured with an optical transient recorder. Luminances of the three color primaries and white for all 256 digital driving levels (DDLs) were measured with a spectroradiometer. Between the luminances of neighboring DDLs, just noticeable differences were calculated according to a perceptual model developed for medical displays. Luminances of full screen (FS) stimuli were compared to luminances of smaller stimuli with identical DDLs. All measured luminance transition times were below 300 μs. Luminances were independent of the luminance in the preceding frame. However, for the single color primaries, up to 50.5% of the luminances of neighboring DDLs were not perceptually distinguishable. If two color primaries were active simultaneously, between 36.7% and 55.1% of neighboring luminances for increasing DDLs of the third primary were even decreasing. Moreover, luminance saturation effects were observed when too many pixels were active simultaneously. This effect was strongest for white; a small white patch was close to 400 cd/m(2), but in FS the luminance of white saturated at 162 cd/m(2). Due to different saturation levels, the luminance of FS green and FS yellow could exceed the luminance of FS white for identical DDLs. The OLED temporal characteristics are excellent and superior to those of LCDs. However, the OLEDs revealed severe perceptually relevant artifacts with

  11. Cinematography of weakly - luminous transient phenomena using image converters

    International Nuclear Information System (INIS)

    Stevenin, P.; Jacquot, C.

    1966-01-01

    After a review on the physical of optical informations emitted by a light source of weak intensity and short duration, the authors describe a high gain device by associating two image converters. The present specifications are given in the domain of high speed cinematography and spectrometry. (authors) [fr

  12. Luminous lip-prints as criminal evidence.

    Science.gov (United States)

    Castelló, Ana; Alvarez-Seguí, Mercedes; Verdú, Fernando

    2005-12-20

    Luminescence is specially a useful property for the search of invisible evidences at the scene of a crime. In the latent fingerprints particular case, there are at one's disposal fluorescent reagents for their localization. The study of latent lip prints (that is lip prints from protective lipstick, or permanent or long-lasting lipstick that do not leave any visible marks) is more recent than fingerprints study. Because of the different composition of both types of prints, different reagents have been tried out on their developing. Although, lysochromes are particularly useful reagents to obtain latent lip prints, it may occur on coloured or multicoloured surfaces, the developing is not perceived due to contrast problems between the reagent and the surface where the print is searched. Again, luminescence offers the possibility to solve this problem. Nile Red is being studied as a potential developer for latent lip prints. The results on very old prints (over 1year) indicate that this reagent is highly efficient to get latent lip prints.

  13. The nature of the nebula associated with the luminous blue variable star WRA 751

    OpenAIRE

    Hutsemekers, Damien; van Drom, E.

    1991-01-01

    Narrow-band filter imagery as well as medium to high resolution spectroscopy of the nebula surrounding the luminous blue variable (LBV) star WRA 751 are presented. The nebula appears as a slowly expanding H II region of low excitation characterized by a significant N/O overabundance which may be due to the presence in the nebula of nuclear processed material ejected by the star. With the recent discovery of a nebula around HR Car, all but one known galactic LBVs are now shown to be associated...

  14. Selected luminal mucosal complications of adult celiac disease

    OpenAIRE

    Freeman, Hugh

    2009-01-01

    Hugh J FreemanDepartment of Medicine (Gastroenterology), University of British Columbia, Vancouver, BC, CanadaAbstract: Celiac disease is a gluten-dependent intestinal disorder that appears to be associated with several clinical conditions. Some involve the luminal mucosa of the stomach and intestinal tract and may, occasionally, complicate the course of celiac disease. Collagenous colitis has been associated with celiac disease and may lead to chronic diarrhea. Conversely, some of t...

  15. Underlying mechanisms of transient luminous events: a review

    OpenAIRE

    V. V. Surkov; M. Hayakawa

    2012-01-01

    Transient luminous events (TLEs) occasionally observed above a strong thunderstorm system have been the subject of a great deal of research during recent years. The main goal of this review is to introduce readers to recent theories of electrodynamics processes associated with TLEs. We examine the simplest versions of these theories in order to make their physics as transparent as possible. The study is begun with the conventional mechanism for air breakdown at stratospheric...

  16. Van-de-Graaf accelerator operation with laser source of highly-charged heavy ions

    International Nuclear Information System (INIS)

    Barabash, L.S.; Golubev, A.A.; Koshkarev, S.G.; Krechet, K.I.; Sharkov, B.Y.; Shumshurov, A.V.

    1988-01-01

    Multicharged ions (Z = +1 divided-by +10) of practically any elements of the periodical table have been generated by the laser source based on a simple in operation and fabrication laser. One of the features of the laser source is that the energy needed for plasma heating is transported to the target from a great distance. In this case the target can be placed under high voltage or in a magnetic field. These advantages of the laser source are particularly important for its application in the Van-de-Graaf accelerator, where absence of resonance units allows to accelerate ions with any charge-to-mass ratio. The goal of this paper consists in designing a laser source of highly- charged heavy ions in the Van-de-Graaf accelerator and in measuring charge spectra of the accelerated ion beam. The peculiarities of this accelerator are taken into account in the discussion of the source scheme. Such peculiarities include potential up to 5 MV on the high-voltage conductor, where the ion source is placed, and high up to 15 atm gas environment pressure

  17. A high-efficiency positive (negative) surface ionization source for radioactive ion beam (abstract)a

    International Nuclear Information System (INIS)

    Alton, G.D.; Mills, G.D.

    1996-01-01

    A versatile, new concept, spherical-geometry, positive (negative) surface-ionization source has been designed and fabricated which will have the capability of generating both positive- and negative-ion beams without mechanical changes to the source. The source utilizes a highly permeable, high-work-function Ir ionizer (φ≡5.29 eV) for ionizing highly electropositive atoms/molecules; while for negative-surface ionization, the work function is lowered to φ≡1.43 eV by continually feeding cesium vapor through the ionizer matrix. The use of this technique for negative ion beam generation has the potential of overcoming the chronic poisoning effects experienced with LaB 6 while enhancing considerably the efficiency for negative surface ionization of atoms and molecules with intermediate electron affinities. The flexibility of operation in either mode makes it especially attractive for radioactive ion beam applications and, therefore, the source will be used as a complementary replacement for the high-temperature electron impact ionization sources presently in use at the Holifield radioactive beam facility. The design features and operational principles of the source will be described in this report. copyright 1996 American Institute of Physics

  18. Experimental progress on virtual-cathode very high power microwave source development

    International Nuclear Information System (INIS)

    Fazio, M.V.; Hoeberling, R.F.

    1987-01-01

    The evolution of rf accelerator technology toward high-power, high-current, low-emittance beams produces an ever-increasing demand for efficient, very high power microwave sources. The present klystron technology has performed very well but is not expected to produce reliable gigawatt peak-power units in the 1- to 10-GHz regime. Further major advancements must involve other types of sources. The reflexing electron sources can produce microwave powers at the gigawatt level and have demonstrated operation from 800 MHz to 40 GHz. Pulse length appears to be limited by electron-beam diode closure, and reflexing electron devices have been operated in a repetitively pulsed mode. An experiment is under way to investigate concepts to stabilize the frequency of the virtual cathode source. If one can successfully frequency and phase lock this source to an external signal, then this source can operate as a very high power microwave amplifier making it practical for accelerator applications. The progress on an experiment to test these concepts will be discussed

  19. Interconnected High-Voltage Pulsed-Power Converters System Design for H− Ion Sources

    CERN Document Server

    Aguglia, D

    2014-01-01

    This paper presents the design and experimental validations of a system of three new high-voltage (HV) pulsedpower converters for the H− sources. The system requires three pulsed voltages (50, 40, and 25 kV to ground) at 2-Hz repetition rate, for 700 μs of usable flat-top. The solution presents ripplefree output voltages and minimal stored energy to protect the ion source from the consequences of arc events. Experimental results on the final full-scale prototype are presented. In case of short-circuit events, the maximal energy delivered to the source is in the Joule range. HV flat-top stability of 1% is experimentally achieved with a simple Proportional-Integral- Derivative regulation and preliminary tuned H− source (e.g., radio frequency control, gas injection, and so forth). The system is running since more than a year with no power converter failures and damage to the source.

  20. Development of a high brightness ion source for IFMIF and preliminary test results

    International Nuclear Information System (INIS)

    Iga, Takashi; Okumura, Yoshikazu; Kashiwagi, Mieko

    2001-05-01

    Development of a high brightness ion source for the 40MeV/250mA deuteron beam accelerator, IFMIF, is in progress at JAERI. A prototype ion source using hot filament cathodes has been developed. This ion source consists of a multi-cusp plasma generator and a two-stage accelerator. Beam optics has been investigated at the energy of up to 60keV. Experimental results of the beam optics agreed well with the simulation by assuming that the equivalent ion mass is 2.38. Ion beam of 60keV/100mA H+, which corresponds to ion beam of 100keV/220mA D+, was obtained with optimum perveance (minimum divergence). This result indicates that the current requirement for the IFMIF ion source would be satisfied with this ion source. (author)

  1. The second COS-B catalogue of high-energy γ-ray sources

    International Nuclear Information System (INIS)

    Hermsen, W.

    1981-01-01

    Gamma-ray emission is produced in many localized regions. 13 high energy gamma-ray sources have previously been detected but because of difficulties of identification the nature of these sources is not clear. Further data from COS-B has been accumulated and allow a more systematic search for gamma-ray sources in the Galaxy. The 32 observations used were made between August 1975 and December 1978. Only events above 100 MeV have been included. The positions of the 25 detected gamma-ray sources are given. Only four sources of the catalogue have been identified, two with the Crab and Vela pulsars, one with 3C273 and one with the rho-Oph cloud complex. For the remainder, all but one of which lie close to the galactic disc, no unambiguous counterparts appear to exist at other wavelengths. (U.K.)

  2. High dose-rate brachytherapy source localization: positional resolution using a diamond detector

    International Nuclear Information System (INIS)

    Nakano, T; Suchowerska, N; Bilek, M M; McKenzie, D R; Ng, N; Kron, T

    2003-01-01

    A potential real-time source position verification process for high dose-rate (HDR) brachytherapy treatment is described. This process is intended to provide immediate confirmation that a treatment is proceeding according to plan, so that corrective action can be taken if necessary. We show that three dosimeters are in principle sufficient and demonstrate the feasibility of the process using a diamond detector and an Ir-192 source. An error analysis including all identified sources of error shows that this detector is capable of locating the distance to the source to within 2 mm for distances up to 12 cm. This positional accuracy is less than the diameter of typical HDR catheters indicating that a diamond detector can be used to accurately determine the distance to the source. The uncertainty in the distance is found to increase with distance

  3. The Role of Luminance and Chromaticity on Symmetry Detection

    Directory of Open Access Journals (Sweden)

    Chia-Ching Wu

    2011-05-01

    Full Text Available We investigated the effect of luminance and chromaticity on symmetry detection with the noise masking paradigm. In each trial, a random dot noise mask was presented in both intervals. A symmetric target was randomly presented in one interval while a random dot control was presented in the other. The orientation of the symmetric axis of the target was either 45°or −45° diagonal. The task of the observer was to determine which interval contained a symmetric target. The dots in both the target and the mask was painted with 1 to 4 colors selected from white, black, red, green, blue and yellow. We measured the target density threshold at various noise densities. Our results showed that when the number of the colors in the images was equal, the thresholds were lower in the luminance conditions than in the chromaticity conditions. In addition, the thresholds decreased with the increment of the number of the colors in the images. This suggests that (1 the luminance symmetry detection mechanism is more sensitive than chromaticity one and (2 that, contrasted to the prediction of an uncertainty model, the diversity in color facilitates symmetry detection.

  4. Wavelength and ambient luminance dependence of laser eye dazzle.

    Science.gov (United States)

    Williamson, Craig A; McLin, Leon N; Rickman, J Michael; Manka, Michael A; Garcia, Paul V; Kinerk, Wesley T; Smith, Peter A

    2017-10-10

    A series of experiments has been conducted to quantify the effects of laser wavelength and ambient luminance on the severity of laser eye dazzle experienced by human subjects. Eight laser wavelengths in the visible spectrum were used (458-647 nm) across a wide range of ambient luminance conditions (0.1-10,000  cd·m -2 ). Subjects were exposed to laser irradiance levels up to 600  μW·cm -2 and were asked to recognize the orientation of optotypes at varying eccentricities up to 31.6 deg of visual angle from the laser axis. More than 40,000 data points were collected from 14 subjects (ages 23-64), and these were consolidated into a series of obscuration angles for comparison to a theoretical model of laser eye dazzle. Scaling functions were derived to allow the model to predict the effects of laser dazzle on vision more accurately by including the effects of ambient luminance and laser wavelength. The updated model provides an improved match to observed laser eye dazzle effects across the full range of conditions assessed. The resulting model will find use in a variety of laser safety applications, including the estimation of maximum dazzle exposure and nominal ocular dazzle distance values.

  5. An accelerated test method of luminous flux depreciation for LED luminaires and lamps

    International Nuclear Information System (INIS)

    Qian, C.; Fan, X.J.; Fan, J.J.; Yuan, C.A.; Zhang, G.Q.

    2016-01-01

    Light Emitting Diode (LED) luminaires and lamps are energy-saving and environmental friendly alternatives to traditional lighting products. However, current luminous flux depreciation test at luminaire and lamp level requires a minimum of 6000 h testing, which is even longer than the product development cycle time. This paper develops an accelerated test method for luminous flux depreciation to reduce the test time within 2000 h at an elevated temperature. The method is based on lumen maintenance boundary curve, obtained from a collection of LED source lumen depreciation data, known as LM-80 data. The exponential decay model and Arrhenius acceleration relationship are used to determine the new threshold of lumen maintenance and acceleration factor. The proposed method has been verified by a number of simulation studies and experimental data for a wide range of LED luminaire and lamp types from both internal and external experiments. The qualification results obtained by the accelerated test method agree well with traditional 6000 h tests. - Highlights: • We develop an accelerated test method for LED luminaires and lamps. • The method is proposed based on a “Boundary Curve” concept. • The parameters of the boundary curve are extracted from LM-80 test reports. • Qualification results from the proposed method agree with ES requirements.

  6. Effect of luminal or circulating nitrite on colonic ion movement in the rat

    International Nuclear Information System (INIS)

    Radcliffe, B.C.; Nance, S.H.; Deakin, E.J.; Roediger, W.E.W.

    1987-01-01

    The disposition of intravenously or luminally administered nitrite across the colonic mucosa and its effect on ion movement into or from the colon was assessed in anesthetized Porton rats using the isolated colon instilled either with sodium chloride or sodium chloride with sodium butyrate. Ionic changes in the colon after intravenous injection of 10 μmol NaNO 2 were compared with those occurring after injection of 10 μmol NaCl. After intravenous administration of nitrite, both nitrite and nitrate appeared in the colonic instillate in a ratio of 1:1. Nitrite increased chloride absorption (110%) and bicarbonate production (20%) when 40 mM butyrate was included in the instillate. Net sodium absorption, measured in the whole colon, was unchanged. Intravenous nitrite had no effect on ionic movement in the absence of butyrate. When NaNO 2 was included luminally with the sodium chloride-butyrate instillate, bicarbonate production rate increased, but sodium and chloride absorption were unaffected. Nitrite concentration in the instillate decreased during the 40-min experimental period at a rate of 0.275 nmol·min -1 ·cm -2 and nitrate appeared at a rate of 0.037 nmol·min -1 ·cm -2 . The authors conclude that nitrite stimulates bicarbonate production in the colon, probably by stimulating the oxidation by butyrate, the main source of CO 2 generation by the colonic mucosa

  7. Performance and reliability of TPE-2 device with pulsed high power source

    International Nuclear Information System (INIS)

    Sato, Y.; Takeda, S.; Kiyama, S.

    1987-01-01

    The performance and the reliability of TPE-2 device with pulsed high power sources are described. To obtain the stable high beta plasma, the reproducibility and the reliability of the pulsed power sources must be maintained. A new power crowbar system with high efficiency and the switches with low jitter time are adopted to the bank system. A monitor system which always watches the operational states of the switches is developed too, and applied for the fast rising capacitor banks of TPE-2 device. The reliable operation for the bank has been realized, based on the data of switch monitor system

  8. WISE Discovery of Hyper Luminous Galaxies at z=2-4 and Their Implications for Galaxy and AGN Evolution

    Science.gov (United States)

    Tsai, Chao Wei; Eisenhardt, Peter; Wu, Jingwen; Bridge, Carrie; Assef, Roberto; Benford, Dominic; Blain, Andrew; Cutri, Roc; Griffith, Robert L.; Jarrett, Thomas; hide

    2014-01-01

    On behalf of the WISE Science team, we present the discovery of a class of distant dust-enshrouded galaxies with extremely high luminosity. These galaxies are selected to have extreme red colors in the mid-IR using NASA's Wide-field Infrared Survey Explorer (WISE). They are faint in the optical and near-IR, predominantly at zeta = 2-4, and with IR luminosity > 10(exp 13) Solar Luminosity, making them Hyper-Luminous Infrared Galaxies (HyLIRGs). SEDs incorporating the WISE, Spitzer, and Herschel PACS and SPIRE photometry indicate hot dust dominates the bolometric luminosity, presumably powered by AGN. Preliminary multi-wavelength follow-up suggests that they are different from normal populations in the local M-sigma relation. Their low source density implies that these objects are either intrinsically rare, or a short-lived phase in a more numerous population. If the latter is the case, these hot, dust-enshrouded galaxies may be an early stage in the interplay between AGN and galaxies.

  9. Development of a High-Brightness VHF Electron Source at LBNL

    International Nuclear Information System (INIS)

    Lidia, Steven M.; Sannibale, Fernando; Staples, John W.; Virostek, Steve P.; Wells, Russell P.

    2007-01-01

    Currently proposed ERL and high average power FEL projects require electron beam sources that can generate ∼1nC bunch charges at high repetition rates. Many proposed sources are based around either high voltage DC or microwave RF guns, each with its particular set of technological limits and system complications. We propose a novel solution that greatly diminishes high voltage breakdown issues while also decreasing peak RF power requirements in a warm copper device, and that has the benefit of mapping the rf oscillation period much more closely to the required beam repetition rate. We present the initial RF and mechanical design for a 750kV electron source and beam injection system utilizing a gun resonant in the VHF band. Beam dynamics simulations demonstrate excellent beam quality preservation and transport

  10. Contribution from individual nearby sources to the spectrum of high-energy cosmic-ray electrons

    International Nuclear Information System (INIS)

    Sedrati, R.; Attallah, R.

    2014-01-01

    In the last few years, very important data on high-energy cosmic-ray electrons and positrons from high-precision space-born and ground-based experiments have attracted a great deal of interest. These particles represent a unique probe for studying local comic-ray accelerators because they lose energy very rapidly. These energy losses reduce the lifetime so drastically that high-energy cosmic-ray electrons can attain the Earth only from rather local astrophysical sources. This work aims at calculating, by means of Monte Carlo simulation, the contribution from some known nearby astrophysical sources to the cosmic-ray electron/positron spectra at high energy (≥10GeV). The background to the electron energy spectrum from distant sources is determined with the help of the GALPROP code. The obtained numerical results are compared with a set of experimental data

  11. Contribution from individual nearby sources to the spectrum of high-energy cosmic-ray electrons

    Energy Technology Data Exchange (ETDEWEB)

    Sedrati, R., E-mail: rafik.sedrati@univ-annaba.org; Attallah, R.

    2014-04-01

    In the last few years, very important data on high-energy cosmic-ray electrons and positrons from high-precision space-born and ground-based experiments have attracted a great deal of interest. These particles represent a unique probe for studying local comic-ray accelerators because they lose energy very rapidly. These energy losses reduce the lifetime so drastically that high-energy cosmic-ray electrons can attain the Earth only from rather local astrophysical sources. This work aims at calculating, by means of Monte Carlo simulation, the contribution from some known nearby astrophysical sources to the cosmic-ray electron/positron spectra at high energy (≥10GeV). The background to the electron energy spectrum from distant sources is determined with the help of the GALPROP code. The obtained numerical results are compared with a set of experimental data.

  12. A high field optical-pumping spin-exchange polarized deuterium source

    International Nuclear Information System (INIS)

    Coulter, K.P.; Holt, R.J.; Kinney, E.R.; Kowalczyk, R.S.; Poelker, M.; Potterveld, D.H.; Young, L.; Zeidman, B.; Toporkov, D.

    1992-01-01

    Recent results from a prototype high field optical-pumping spin-exchange polarized deuterium source are presented. Atomic polarization as high as 62% have been observed with an intensity of 6.3 x 10 17 atoms-sec -1 and 65% dissociation fraction

  13. Far infrared spectroscopy of high-Tc superconductors at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Perkowitz, S.; Williams, G.P.

    1989-01-01

    This paper reports the first far infrared transmission spectra for micron-thick films of high-T c rare-earth superconductors such as DyBaCuO, with implications for the superconducting gap. Spectra were obtained at Brookhaven's National Synchrotron Light Source, a new high-intensity, broad-band millimeter to infrared source. The National Synchrotron Light Source at Brookhaven National Laboratory, known for powerful X-ray and UV output, is also a high-intensity (10 to 1000 times above a black body), high-brightness (intensity per solid angle), broad-band, picosecond, millimeter to infrared source. These features make it valuable for far-infrared condensed matter experiments, especially those in highly absorbing or extremely small systems. A first application has been to measure very small infrared transmissions through thick bulk-like high-T c superconducting films. Preliminary measurements through films of the conventional superconductor Nb 3 Ge established techniques. These were followed by the first measurements (to the author's knowledge) through micron-thick films of high-T c rare-earth superconductors such as DyBaCuO over 10-300 cm -1 , which includes the superconducting gap according to BCS or moderately strong-coupled theory. The authors discuss the transmission evidence bearing on the existence of a gap and other important features of high-T c superconductors, and describe the synchrotron and instrumentation features which make possible these unusual measurements

  14. A high brightness source for nano-probe secondary ion mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Smith, N.S. [Oregon Physics LLC, 2704 SE 39th Loop, Suite 109, Hillsboro, OR 97123 (United States)], E-mail: n.smith@oregon-physics.com; Tesch, P.P.; Martin, N.P.; Kinion, D.E. [Oregon Physics LLC, 2704 SE 39th Loop, Suite 109, Hillsboro, OR 97123 (United States)

    2008-12-15

    The two most prevalent ion source technologies in the field of surface analysis and surface machining are the Duoplasmatron and the liquid metal ion source (LMIS). There have been many efforts in this area of research to develop an alternative source [; N.S. Smith, W.P. Skoczylas, S.M. Kellogg, D.E. Kinion, P.P. Tesch, O. Sutherland, A. Aanesland, R.W. Boswell, J. Vac. Sci. Technol. B 24 (6) (2006) 2902-2906] with the brightness of a LMIS and yet the ability to produce secondary ion yield enhancing species such as oxygen. However, to date a viable alternative has not been realized. The high brightness and small virtual source size of the LMIS are advantageous for forming high resolution probes but a significant disadvantage when beam currents in excess of 100 nA are required, due to the effects of spherical aberration from the optical column. At these higher currents a source with a high angular intensity is optimal and in fact the relatively moderate brightness of today's plasma ion sources prevail in this operating regime. Both the LMIS and Duoplasmatron suffer from a large axial energy spread resulting in further limitations when forming focused beams at the chromatic limit where the figure-of-merit is inversely proportional to the square of the energy spread. Also, both of these ion sources operate with a very limited range of ion species. This article reviews some of the latest developments and some future potential in this area of instrument development. Here we present an approach to source development that could lead to oxygen ion beam SIMS imaging with 10 nm resolution, using a 'broad area' RF gas phase ion source.

  15. High-power microwave generation from a frequency-stabilized virtual cathode source

    International Nuclear Information System (INIS)

    Fazio, M.V.; Hoeberling, R.F.; Kinross-Wright, J.

    1988-01-01

    The evolution of virtual cathode based high-power microwave-source technology has been directed primarily toward achieving higher peak-power levels. As peak powers in excess of 10 GW have been reported, attention has begun to focus on techniques for producing a more frequency- and phase-stable virtual cathode source. Free-running virtual cathode microwave sources characteristically exhibit bandwidths in a single pulse of tens of percent, which makes them unsuitable for many applications such as power sources for phased array antennas and microwave linear accelerators. Presented here are results of an experimental approach utilizing a high-Q, resonant cavity surrounding the oscillating virtual cathode to achieve frequency stabilization and repeatable narrow-band operation. A cylindrical cavity resonator is used with the microwave power being extracted radially through circumferential slot apertures into L-band waveguide

  16. A Langmuir probe system for high power RF-driven negative ion sources on high potential

    International Nuclear Information System (INIS)

    McNeely, P; Christ-Koch, S; Fantz, U; Dudin, S V

    2009-01-01

    A fully automated Langmuir probe system capable of operating simultaneously with beam extraction has been developed and commissioned for the negative hydrogen ion source testbeds at IPP Garching. It allows the measurement of temporal and spatial distributions of the plasma parameters within a single plasma pulse ( 10 18 m -3 ) and hot (T e > 10 eV) plasma with bi-Maxwellian electron energy distribution at low pressures. The plasma found near the plasma grid is very different being of low density (≤10 17 m -3 ) and very cold (T e < 2 eV). This plasma is also strongly influenced by the presence of caesium, the potential of the plasma grid, and if an ion beam is extracted from the source. Caesium strongly reduces the plasma potential of the source and enhances the negative ion density near the plasma grid. Extracting an ion beam is observed to reduce the electron density and increase the potential near the plasma grid. Applying a potential greater than the plasma potential to the plasma grid is found to significantly decrease the electron density near the plasma grid.

  17. A beamline for high-pressure studies at the Advanced Light Source with a superconducting bending magnet as the source.

    Science.gov (United States)

    Kunz, Martin; MacDowell, Alastair A; Caldwell, Wendel A; Cambie, Daniella; Celestre, Richard S; Domning, Edward E; Duarte, Robert M; Gleason, Arianna E; Glossinger, James M; Kelez, Nicholas; Plate, David W; Yu, Tony; Zaug, Joeseph M; Padmore, Howard A; Jeanloz, Raymond; Alivisatos, A Paul; Clark, Simon M

    2005-09-01

    A new facility for high-pressure diffraction and spectroscopy using diamond anvil high-pressure cells has been built at the Advanced Light Source on beamline 12.2.2. This beamline benefits from the hard X-radiation generated by a 6 T superconducting bending magnet (superbend). Useful X-ray flux is available between 5 keV and 35 keV. The radiation is transferred from the superbend to the experimental enclosure by the brightness-preserving optics of the beamline. These optics are comprised of a plane parabola collimating mirror, followed by a Kohzu monochromator vessel with Si(111) crystals (E/DeltaE approximately equal 7000) and W/B4C multilayers (E/DeltaE approximately equal 100), and then a toroidal focusing mirror with variable focusing distance. The experimental enclosure contains an automated beam-positioning system, a set of slits, ion chambers, the sample positioning goniometry and area detector (CCD or image-plate detector). Future developments aim at the installation of a second endstation dedicated to in situ laser heating and a dedicated high-pressure single-crystal station, applying both monochromatic and polychromatic techniques.

  18. Ion source techniques for high-speed processing of material surface by ion beams

    International Nuclear Information System (INIS)

    Ishikawa, Junzo

    1990-01-01

    The present paper discusses some key or candidate techniques for future ion source development and such ion sources developed by the author. Several types of microwave ion sources for producing low charge state ions have been developed in Japan. When a microwave plasma cathode developed by the author is adapted to a Kaufman type ion source, the electron emission currents are found to be 2.5 A for argon gas and 0.5-0.9 A for oxygen gas. An alternative ionization method for metal atoms is strongly required for high-speed processing of material surface by metal-ion beams. Detailed discussion is made of collisional ionization of vaporized atoms, and negative-ion production (secondary negative-ion emission by sputtering). An impregnated electrode type liquid-metal ion source developed by the author, which has a porous tip structure, is described. The negative-ion production efficiency is quite high. The report also presents a neutral and ionized alkaline-metal bombardment type heavy negative-ion source, which consists of a cesium plasma ion source, suppressor, target electrode, negative-ion extraction electrode, and einzel lens. (N.K.)

  19. Investigating a multigene prognostic assay based on significant pathways for Luminal A breast cancer through gene expression profile analysis.

    Science.gov (United States)

    Gao, Haiyan; Yang, Mei; Zhang, Xiaolan

    2018-04-01

    The present study aimed to investigate potential recurrence-risk biomarkers based on significant pathways for Luminal A breast cancer through gene expression profile analysis. Initially, the gene expression profiles of Luminal A breast cancer patients were downloaded from The Cancer Genome Atlas database. The differentially expressed genes (DEGs) were identified using a Limma package and the hierarchical clustering analysis was conducted for the DEGs. In addition, the functional pathways were screened using Kyoto Encyclopedia of Genes and Genomes pathway enrichment analyses and rank ratio calculation. The multigene prognostic assay was exploited based on the statistically significant pathways and its prognostic function was tested using train set and verified using the gene expression data and survival data of Luminal A breast cancer patients downloaded from the Gene Expression Omnibus. A total of 300 DEGs were identified between good and poor outcome groups, including 176 upregulated genes and 124 downregulated genes. The DEGs may be used to effectively distinguish Luminal A samples with different prognoses verified by hierarchical clustering analysis. There were 9 pathways screened as significant pathways and a total of 18 DEGs involved in these 9 pathways were identified as prognostic biomarkers. According to the survival analysis and receiver operating characteristic curve, the obtained 18-gene prognostic assay exhibited good prognostic function with high sensitivity and specificity to both the train and test samples. In conclusion the 18-gene prognostic assay including the key genes, transcription factor 7-like 2, anterior parietal cortex and lymphocyte enhancer factor-1 may provide a new method for predicting outcomes and may be conducive to the promotion of precision medicine for Luminal A breast cancer.

  20. High energy supercontinuum sources using tapered photonic crystal fibers for multispectral photoacoustic microscopy

    DEFF Research Database (Denmark)

    Bondu, Magalie; Brooks, Christopher; Jakobsen, Christian

    2016-01-01

    We demonstrate a record bandwidth high energy supercontinuum source suitable for multispectral photoacoustic microscopy. The source has more than 150  nJ/10  nm150  nJ/10  nm bandwidth over a spectral range of 500 to 1600 nm. This performance is achieved using a carefully designed fiber taper...... with large-core input for improved power handling and small-core output that provides the desired spectral range of the supercontinuum source....