WorldWideScience

Sample records for high dose somatostatin

  1. High molecular somatostatin, an interfering factor in radioimmunoassay

    International Nuclear Information System (INIS)

    Diel, F.; Schneider, E.; Baumann, H.

    1977-01-01

    Cyclic Tyr 1 -somatostatin (Tyr 1 -SRIF) is radioiodinated by the lactoperoxidase method. Purification is achieved by Sephadex G-25 adsorption chromatography. Specific anti-SRIF serum (FA1) has been raised in rabbits. A dose response curve is obtained in the range of 5 - 5,000 pg per tube using an antiserum dilution of 1:2,000. There is little cross-reaction with linear somatostatin and none with ocytocin, (lys-, arg-) vasopressin, valinomycin, polymyxin, insulin, glucagon, human growth hormone (hGH), and thyrotropin-releasing hormone (TRH). For recovery tests, extraction procedures are necessary. Thin-layer chromatography (TLC) and polyacrylamide-disc-electrophoresis (Disc-PAGE) are performed to identify the presumed high molecular 125 I-Tyr 1 -SRIF associate. This high molecular associate may represent an interfering factor in the radioimmunoassay for cyclic SRIF. (orig./AJ) [de

  2. Development of 99mTc labelled somatostatin analogues with high affinity for somatostatin receptors

    International Nuclear Information System (INIS)

    Maina, T.; Nock, B.; Nicolopoulou, A.; Tsipra, C.; Poppe, M.; Chiotellis, E.

    2001-01-01

    A recent development in oncology involves the use of metabolically stabilized peptide hormone analogues labelled with metallic radionuclides for the diagnosis or therapy of malignant disease. This approach was successfully applied for the first time in the visualization of somatostatin positive tumours and their metastases with 111 In DTPA-octreotide. In an effort to obtain a 99m Tc somatostatin receptor affine radioligand we describe herein the synthesis, radiochemistry and preliminary biological evaluation of two novel 99m Tc labelled somatostatin analogues, N 4 -TOC and N 4 -RC-160. In these compounds a tetraamine bifunctional unit was covalently attached to the N-terminal (D)Phe 1 of the peptide chain using Boc-protection strategies. The peptide conjugates were purified by high performance liquid chromatography (HPLC) and characterized by UV/Vis and ES-MS spectroscopies. As revealed by HPLC, 99m Tc labelling was quantitative under mild conditions, leading to a single 99m Tc species in high specific activities. Affinity of 99m Tc N 4 -TOC for the somatostatin receptor, as determined by in vitro binding assays in rat brain cortex membranes, was found unaffected by the presence of the bulky metal chelate. The binding properties of 99m Tc N 4 -RC-160 could not be determined by this assay due to an extremely high non-specific binding of this radioligand, and will be shortly investigated by other methods. Tissue distribution in healthy mice revealed that 99m Tc N 4 -TOC is clearing mainly through the kidneys and the urinary tract whereas 99m Tc N 4 -RC-160 shows a high accumulation in the liver as a result of its lipophilicity. Analysis of urine samples by HPLC showed that 99m Tc N 4 -TOC is excreted integer from the body of mice, while 99m Tc N 4 -RC-160 is totally transformed to an unidentified hydrophilic metabolite in vivo. The location of this metabolism is currently investigated. In vivo blocking experiments using animals pre-treated with 50 μg octreotide

  3. Functional somatostatin receptors on a rat pancreatic acinar cell line

    International Nuclear Information System (INIS)

    Viguerie, N.; Tahiri-Jouti, N.; Esteve, J.P.; Clerc, P.; Logsdon, C.; Svoboda, M.; Susini, C.; Vaysse, N.; Ribet, A.

    1988-01-01

    Somatostatin receptors from a rat pancreatic acinar cell line, AR4-2J, were characterized biochemically, structurally, and functionally. Binding of 125 I-[Tyr 11 ]Somatostatin to AR4-2J cells was saturable, exhibiting a single class of high-affinity binding sites with a maximal binding capacity of 258 ± 20 fmol/10 6 cells. Somatostatin receptor structure was analyzed by covalently cross-linking 125 I-[Tyr 11 ]somatostatin to its plasma membrane receptors. Gel electrophoresis and autoradiography of cross-linked proteins revealed a peptide containing the somatostatin receptor. Somatostatin inhibited vasoactive intestinal peptide (VIP)-stimulated adenosine 3',5'-cyclic monophosphate (cAMP) formation in a dose-dependent manner. The concentration of somatostatin that caused half-maximal inhibition of cAMP formation was close to the receptor affinity for somatostatin. Pertussis toxin pretreatment of AR4-2J cells prevented somatostatin inhibition of VIP-stimulated cAMP formation as well as somatostatin binding. The authors conclude that AR4-2J cells exhibit functional somatostatin receptors that retain both specificity and affinity of the pancreatic acinar cell somatostatin receptors and act via the pertussis toxin-sensitive guanine nucleotide-binding protein N i to inhibit adenylate cyclase

  4. Somatostatin: a metabolic regulator

    International Nuclear Information System (INIS)

    Dileepan, K.N.; Wagle, S.R.

    1985-01-01

    Somatostatin, the hypothalamic release-inhibiting factor, has been found to stimulate gluconeogenesis in rat kidney cortical slices. Stimulation by somatostatin was linear and dose-dependent. Other bioactive peptides such as cholecystokinin, gastro-intestinal peptide, secretin, neurotensin, vasoactive intestinal peptide, pancreatic polypeptide, beta endorphin and substance P did not affect the renal gluconeogenic activity. Somatostatin-induced gluconeogenesis was blocked by phentolamine (alpha adrenergic antagonist) and prazosin (alpha 1 adrenergic antagonist) but not by propranolol (beta adrenergic antagonist) and yohimbine (alpha 2 adrenergic antagonist) suggesting that the effect is via alpha 1 adrenergic stimuli. Studies on the involvement of Ca 2+ revealed that tissue depletion and omission of Ca 2+ from the reaction mixture would abolish the stimulatory effect of somatostatin. Furthermore, somatostatin enhanced the uptake of 45 calcium in renal cortical slices which could be blocked by lanthanum, an inhibitor of Ca 2+ influx. It is proposed that the stimulatory effect of somatostatin on renal gluconeogenesis is mediated by alpha 1 adrenergic receptors, or those which functionally resemble the alpha 1 receptors and that the increased influx of Ca 2+ may be the causative factor for carrying out the stimulus. 88 references

  5. Kidney protection during peptide receptor radionuclide therapy with somatostatin analogues

    Energy Technology Data Exchange (ETDEWEB)

    Rolleman, Edgar J.; Melis, Marleen; Valkema, Roelf; Krenning, Eric P.; Jong, Marion de [Erasmus MC, Department of Nuclear Medicine, V 220, Rotterdam (Netherlands); Boerman, Otto C. [Radboud University Hospital, Department of Nuclear Medicine, Nijmegen (Netherlands)

    2010-05-15

    This review focuses on the present status of kidney protection during peptide receptor radionuclide therapy (PRRT) using radiolabelled somatostatin analogues. This treatment modality for somatostatin receptor-positive tumours is limited by renal reabsorption and retention of radiolabelled peptides resulting in dose-limiting high kidney radiation doses. Radiation nephropathy has been described in several patients. Studies on the mechanism and localization demonstrate that renal uptake of radiolabelled somatostatin analogues largely depends on the megalin/cubulin system in the proximal tubule cells. Thus methods are needed that interfere with this reabsorption pathway to achieve kidney protection. Such methods include coadministration of basic amino acids, the bovine gelatin-containing solution Gelofusine or albumin fragments. Amino acids are already commonly used in the clinical setting during PRRT. Other compounds that interfere with renal reabsorption capacity (maleic acid and colchicine) are not suitable for clinical use because of potential toxicity. The safe limit for the renal radiation dose during PRRT is not exactly known. Dosimetry studies applying the principle of the biological equivalent dose (correcting for the effect of dose fractionation) suggest that a dose of about 37 Gy is the threshold for development of kidney toxicity. This threshold is lower when risk factors for development of renal damage exist: age over 60 years, hypertension, diabetes mellitus and previous chemotherapy. A still experimental pathway for kidney protection is mitigation of radiation effects, possibly achievable by cotreatment with amifostine (Ethylol), a radiation protector, or with blockers of the renin-angiotensin-aldosterone system. Future perspectives on improving kidney protection during PRRT include combinations of agents to reduce renal retention of radiolabelled peptides, eventually together with mitigating medicines. Moreover, new somatostatin analogues with lower

  6. Kidney protection during peptide receptor radionuclide therapy with somatostatin analogues

    International Nuclear Information System (INIS)

    Rolleman, Edgar J.; Melis, Marleen; Valkema, Roelf; Krenning, Eric P.; Jong, Marion de; Boerman, Otto C.

    2010-01-01

    This review focuses on the present status of kidney protection during peptide receptor radionuclide therapy (PRRT) using radiolabelled somatostatin analogues. This treatment modality for somatostatin receptor-positive tumours is limited by renal reabsorption and retention of radiolabelled peptides resulting in dose-limiting high kidney radiation doses. Radiation nephropathy has been described in several patients. Studies on the mechanism and localization demonstrate that renal uptake of radiolabelled somatostatin analogues largely depends on the megalin/cubulin system in the proximal tubule cells. Thus methods are needed that interfere with this reabsorption pathway to achieve kidney protection. Such methods include coadministration of basic amino acids, the bovine gelatin-containing solution Gelofusine or albumin fragments. Amino acids are already commonly used in the clinical setting during PRRT. Other compounds that interfere with renal reabsorption capacity (maleic acid and colchicine) are not suitable for clinical use because of potential toxicity. The safe limit for the renal radiation dose during PRRT is not exactly known. Dosimetry studies applying the principle of the biological equivalent dose (correcting for the effect of dose fractionation) suggest that a dose of about 37 Gy is the threshold for development of kidney toxicity. This threshold is lower when risk factors for development of renal damage exist: age over 60 years, hypertension, diabetes mellitus and previous chemotherapy. A still experimental pathway for kidney protection is mitigation of radiation effects, possibly achievable by cotreatment with amifostine (Ethylol), a radiation protector, or with blockers of the renin-angiotensin-aldosterone system. Future perspectives on improving kidney protection during PRRT include combinations of agents to reduce renal retention of radiolabelled peptides, eventually together with mitigating medicines. Moreover, new somatostatin analogues with lower

  7. Somatostatin: a metabolic regulator

    Energy Technology Data Exchange (ETDEWEB)

    Dileepan, K.N.; Wagle, S.R.

    1985-12-23

    Somatostatin, the hypothalamic release-inhibiting factor, has been found to stimulate gluconeogenesis in rat kidney cortical slices. Stimulation by somatostatin was linear and dose-dependent. Other bioactive peptides such as cholecystokinin, gastro-intestinal peptide, secretin, neurotensin, vasoactive intestinal peptide, pancreatic polypeptide, beta endorphin and substance P did not affect the renal gluconeogenic activity. Somatostatin-induced gluconeogenesis was blocked by phentolamine (alpha adrenergic antagonist) and prazosin (alpha/sub 1/ adrenergic antagonist) but not by propranolol (beta adrenergic antagonist) and yohimbine (alpha/sub 2/ adrenergic antagonist) suggesting that the effect is via alpha/sub 1/ adrenergic stimuli. Studies on the involvement of Ca/sup 2 +/ revealed that tissue depletion and omission of Ca/sup 2 +/ from the reaction mixture would abolish the stimulatory effect of somatostatin. Furthermore, somatostatin enhanced the uptake of /sup 45/calcium in renal cortical slices which could be blocked by lanthanum, an inhibitor of Ca/sup 2 +/ influx. It is proposed that the stimulatory effect of somatostatin on renal gluconeogenesis is mediated by alpha/sub 1/ adrenergic receptors, or those which functionally resemble the alpha/sub 1/ receptors and that the increased influx of Ca/sup 2 +/ may be the causative factor for carrying out the stimulus. 88 references.

  8. Excessive grooming induced by somatostatin or its analog SMS 201-995

    NARCIS (Netherlands)

    Wimersma Greidanus, T.B. van; Maigret, C.; Krechting, B.

    1987-01-01

    Intracerebroventricular (i.c.v.) administration of somatostatin or SMS 201-995 induces excessive grooming behavior in rats. The grooming inducing effect of somatostatin is rather weak, as doses of 300 ng or less did not result in increased total grooming scores. In contrast a dose of 10 ng SMS

  9. Cholecystokinin inhibits gastrin secretion independently of paracrine somatostatin secretion in the pig

    DEFF Research Database (Denmark)

    Schmidt, P T; Hansen, L; Hilsted, L

    2004-01-01

    BACKGROUND: Cholecystokinin inhibits the secretion of gastrin from antral G cells, an effect that is speculated to be mediated by D cells secreting somatostatin. The aim of the study was to test directly whether cholecystokinin inhibition of antral gastrin secretion is mediated by somatostatin....... METHODS: The effects of CCK on gastrin and somatostatin secretion were studied in isolated vascularly perfused preparations of pig antrum before and after immunoneutralization brought about by infusion of large amounts of a high affinity monoclonal antibody against somatostatin. RESULTS: CCK infusion...... at 10(-9) M and 10(-8) M decreased gastrin output to 70.5% +/- 7.6% (n = 8) and 76.3% +/- 3.6% (n = 7) of basal output, respectively. CCK at 10(-10) M had no effect (n = 6). Somatostatin secretion was dose-dependently increased by CCK infusion and increased to 268 +/- 38.2% (n = 7) of basal secretion...

  10. Evolutionary history of the somatostatin and somatostatin receptors

    Indian Academy of Sciences (India)

    Somatostatin and its receptors have a critical role in mammalian growth through their control pattern of secretion of growth hormone, but the evolutionary history of somatostatin and somatostatin receptors are ill defined. We used comparative whole genome analysis of Danio rerio, Carassius auratus, Xenopus tropicalis, ...

  11. Somatostatin receptors in gastroentero-pancreatic neuroendocrine tumours

    NARCIS (Netherlands)

    W.W. de Herder (Wouter); L.J. Hofland (Leo); A-J. van der Lely (Aart-Jan); S.W.J. Lamberts (Steven)

    2003-01-01

    textabstractFive somatostatin receptor (sst) subtype genes, sst(1), sst(2), sst(3), sst(4) and sst(5), have been cloned and characterised. The five sst subtypes all bind natural somatostatin-14 and somatostatin-28 with high affinity. Endocrine pancreatic and endocrine digestive

  12. Sensitive radioimmunoassay for somatostatin using N-(/sup 125/I)-tyr-somatostatin as labelled antigen

    Energy Technology Data Exchange (ETDEWEB)

    Dupont, A [CHUL, Quebec (Canada). Lab. of Molecular Endocrinology and Service of Gastro-Enterology; Coy, D H; Alvarado-Urbina, G; Cote, J; Meyers, C A; McManus, J; Barden, N; De Lean, A; Labrie, F

    1979-01-01

    A sensitive radioimmunoassay for somatostatin using N-(/sup 125/I)-Tyr-somatostatin is described and compared with using (/sup 125/I)-Tyr/sup 1/-somatostatin. The minimum detectable amount of somatostatin using N-(/sup 125/I)-Tyr-somatostatin as tracer was 0.1 to 0.5 pg, which is approximately 10-fold lower detection limit of the RIA using (/sup 125/I)-Tyr/sup 1/-somatostatin. Moreover, it was found that the shelf-life of N-(/sup 125/I)-Tyr-somatostatin was prolonged in comparison with labelled Tyr/sup 1/-somatostatin. Human pancreatic and gastric extracts displayed immunological similarity to synthetic somatostatin tetradecapeptide.

  13. Effect of vasoactive intestinal polypeptide and somatostatin on secretion of epidermal growth factor and bicarbonate from Brunner's glands

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    The effect of VIP and somatostatin on secretion of epidermal growth factor and bicarbonate from Brunner's glands was investigated in the rat. Vasoactive intestinal polypeptide infused in doses of 10 and 100 ng/kg/h significantly increased epidermal growth factor and bicarbonate output......, but the concentrations did not change. Somatostatin infused at doses of 1, 10, 100 and 1000 ng/kg/h against a background of VIP 100 ng/kg/h inhibited in dose-dependent fashion the stimulated epidermal growth factor and bicarbonate outputs from rat Brunner's gland pouches. Also basal secretion was inhibited...... growth factor and bicarbonate from Brunner's glands, an effect which is inhibited by somatostatin. A possible role for somatostatin in the control of Brunner's gland secretion is suggested....

  14. Evolutionary history of the somatostatin and somatostatin receptors

    Indian Academy of Sciences (India)

    Table 1. The identified somatostations. Somatostatin (SST1). Name. Scientific name. Length. High ID (to). Low ID (to) Chromosome. GS. Drs. Danio rerio. 324. 48.1 mms ...... ancestral source. References. Baranowska B., Chmielowska M., Wolinska-Witort E., Bik W.,. Baranowska-Bik A. and Martynska L. 2006 Direct effect of.

  15. 99Tcm labelling and in vitro binding of dextran-somatostatin conjugate

    International Nuclear Information System (INIS)

    Cui Haiping; China Inst. of Atomic Energy, Beijing; Zhai Shizhen; Du Jin; Beijing Univ., Beijing

    2006-01-01

    Natural somatostatin and dextran-20 are used to synthesis somatostatin-dextran (SMS-Dx 20 ). The in vitro somatostatin receptor competition binding study of somatostatin-dextran is carried out by using rate brain cortex membranes (express somatostatin receptor type 2) and 125 I-Tyr 3 -Octreotide as a radioligand. The somatostatin-dextran conjugate is then labelled with 99 Tc m using SnCl 2 as reduce agent and tested for its in vitro binding properties. The somatostatin-dextran conjugate shows high somatostatin receptor binding affinity, i.e. in the same IC 50 value as the reference ligand Octreotide (IC 50 ∼5.95 nmol/L). The labelling efficiency is more than 85%. The specific binding of 99 Tc m labeled somatostatin-dextran conjugate is 25%-40%. The somatostatin-dextran conjugate is worthy of further investigation for 99 Tc m radiolabeling with diagnostic possibilities for somatostatin receptor positive tumors. (authors)

  16. Radioautographic localization of somatostatin-14 and somatostatin-28 binding sites in the rat brain

    International Nuclear Information System (INIS)

    Leroux, P.; Pelletier, G.

    1984-01-01

    Somatostatin-14 (S14) and its precursor, somatostatin-28 (S28), are widely distributed throughout the rat brain, suggesting that they could act as neurotransmitter or neuromodulator in the central nervous system. The present study was undertaken to study the localization of S14 and S28 receptors in the rat brain determined by ''in vitro'' radioautography. The study performed on slide mounted frozen brain section with iodinated S14 and S28 analogs revealed an identical distribution of binding sites for the two forms of somatostatin. A good correlation could be observed between receptor distribution and immunohistologically localized neuropeptides except for striatum and hypothalamus. However, receptors were not detectable in the hypothalamus and were found in low concentration in the caudate-putamen nucleus, two regions containing high amounts of S28 and S14, suggesting a high occupancy of receptors in these areas by endogenous peptides or an inverse correlation between receptor and peptide concentrations

  17. High sensitivity of the in vivo detection of somatostatin receptors by 111Indium (DTPA-Octreotide)-scintigraphy in meningioma patients

    International Nuclear Information System (INIS)

    Hildebrandt, G.; Luyken, C.; Klug, N.; Scheidhauer, K.; Schicha, H.; Dahms, P.; Krisch, B.

    1994-01-01

    The recent availability of isotope-labelled somatostatin analogues has allowed one to detect somatostatin receptors in normal tissue as well as in endocrine or non-endocrine cranial tumours. The purpose of the present study was to establish the value of somatostatin receptor scintigraphy using an 111 indium-labelled somatostatin analogue, octreotide, in the diagnostic work-up of meningioma patients. Twenty-two patients (16 women, 6 men, aged from 19-70 years) with newly diagnosed, residual or recurrent cranial meningiomas were examined. 111 indium-labelled DTPA-octreotide was injected i.v.. Planar and tomographic images were obtained with a gamma camera 4-6, and 24 hours after injection. In all of the meningiomas studies a high density of somatostatin receptor was detected by scintigraphy. No false negative test result was found. Due to this, a 100% predictive value of a negative test was calculated. However, when the tumours were taken in culture differing staining intensity could be seen in the light- and electron microscopic level even on individual cells of a single culture when silver intensified somatostatin-gold was used as ligand. We conclude, that in vivo somatostatin receptor scintigraphy may aid in the pre-operative differential diagnosis of skull base tumours

  18. Immuno-reactive somatostatin in the cerebro-spinal fluid

    International Nuclear Information System (INIS)

    Kohler, J.

    1983-01-01

    In the present work the lumbar cerebro-spinal fluid of 178 patients with different neurological affections was examined with the aid of a specific radioimmunoassay for somatostatin. 18 patients without any pathologic neurological findings served as controls. In degenerative diseases of the brain, reduced somatostatin levels in the cerebro-spinal fluid as compared to the controls were measured. In 3 patients with isolated cerebellar atrophy no reduction of the somatostatin content was found; rather the values were highly normal. Huntington-Chorea also is a case apart. In patients with manifest affections, the somatostatin reduction, amounting to 54.6%, was particularly notable as compared to the controls. By contrast, degenerative diseases with predominant medullary and spastic affection are characterized by significantly increased somatostatin levels. Again, in non-spastic patients the values were not significantly different from those of the controls. Patients with inflammations of the brain and meminges as well as with tumors of the nervous system showed somatostatin levels increased by about 60.8% respectively 51.8% as compared to the controls. Epileptic patients normally exhibit a reduced somatostatin level in the cerebro-spinal fluid, but the reduction is not significant. Disseminated encephalomyclitis, whether chromic or acute, is not found to be associated with significant modifications of the somatostatin level in the cerebro-spinal fluid. Strikingly, however, patients in which the disease took a serious or very serious clinical course showed also the lowest somatostatin levels in the cerebro-spinal fluid. In patients exhibiting the roof compression symptom in consequence of a prolapse of the disk, no significant modifications were found. By contrast, in patients with the symptoms of a transverse lesion, significantly increased somatostatin values were measured. (orig./MG) [de

  19. Ga-66 labeled somatostatin analogue DOTA-DPhe1-Tyr3-octreotide as a potential agent for positron emission tomography imaging and receptor mediated internal radiotherapy of somatostatin receptor positive tumors

    International Nuclear Information System (INIS)

    Ugur, Oemer; Kothari, Paresh J.; Finn, Ronald D.; Zanzonico, Pat; Ruan, Shutian; Guenther, Ilonka; Maecke, Helmut R.; Larson, Steven M.

    2002-01-01

    Radionuclide labeled somatostatin analogues selectively target somatostatin receptor (SSTR)-expressing tumors as a basis for diagnosis and treatment of these tumors. Recently, a DOTA-functionalized somatostatin analogue, DOTATOC (DOTA-DPhe 1 -Tyr 3 -octreotide) has been developed. This compound has been shown to be superior to the other somatostatin analogues as indicated by its uniquely high tumor-to-non-target tissue ratio. DOTATOC can be labeled with a variety of radiometals including gallium radioisotopes. Gallium-66 is a positron emitting radionuclide (T 1/2 =9.5 hr; β + =56%), that can be produced in carrier free form by a low-beam energy cyclotron. In this study we investigated SSTR targeting characteristics of 66 Ga-DOTATOC in AR42J rat pancreas tumor implanted nude mice as a potential agent for diagnosis and receptor-mediated internal radiotherapy of SSTR-expressing tumors. We compared our results with 67 Ga- and 68 Ga- labeled DOTATOC. The radiolabeling procedure gave labeling yield ranged from 85-95% and radiochemical and chemical purity was >95%. In-vitro competitive binding curves and in-vivo competitive displacement studies with an excess of unlabeled peptide indicates that there is specific binding of the radioligand to SSTR. Animal biodistribution data and serial microPET TM images demonstrated rapid tumor uptake and rapid clearance from the blood and all tissues except kidney. Maximum % ID/g values for tumor were 10.0±0.7, 13.2±2.1 and 9.8±1.5 for 66 Ga-, 67 Ga-, and 68 Ga-DOTATOC, respectively. Calculated tumor, kidney and bone marrow doses for 66 Ga-DOTATOC based on biodistribution data were 178, 109 and 1.2 cGy/MBq, respectively. We conclude that 66 Ga labeled DOTATOC can be used for PET diagnosis and quantitative imaging-based dosimetry of SSTR positive tumors. 66 Ga-DOTATOC may also be used in higher doses for ablation of these tumors. However, kidney is the critical organ for toxicity (tumor/kidney ratio 1.64), and high kidney uptake must

  20. Somatostatin ontogenesis in the gastrointestinal and pancreatic tract: study in normal rats and during a induced diabetes in neonates rats

    International Nuclear Information System (INIS)

    Cunha, M.C.

    1980-01-01

    The ontogenic studies of somatostatin of pancreas, ileum and duodenum of Wistar rats and the rats with induced diabetes were done. The radioimmunologic method to dose the somatostatin was used. (L.M.J.)

  1. Depletion of somatostatin-like immunoreactivity in the rat central nervous system by cysteamine

    International Nuclear Information System (INIS)

    Sagar, S.M.; Landry, D.; Millard, W.J.; Badger, T.M.; Arnold, M.A.; Martin, J.B.

    1982-01-01

    Selective neurotoxins have been of value in providing a means for specifically interfering with the actions of endogenous neurotransmitter candidates. Others have shown cysteamine (CSH) to deplete the gastrointestinal tract and hypothalamus of rats of immunoreactive somatostatin, suggesting a toxic action of that compound directed against somatostatin-containing cells. The present study further defines the actions of cysteamine on somatostatin in the central nervous system. (CNS). Cysteamine hydrochloride administered subcutaneously results in a depletion of somatostatin-like immunoreactivity (SLI) in the retina, brain, and cervical spinal cord of rats. The effect is demonstrable at doses of 30 mg/kg of body weight and above, occurs within 2 to 4 hr of a single injection of the drug, and is largely reversible within 1 week. The mean depletion of SLI observed within the CNS varies from 38% in cerebral cortex to 65% in cervical spinal cord 24 hr following administration of CSH, 300 mg/kg of body weight, s.c. By gel permeation chromatography, all molecular weight forms of SLI are affected, with the largest reductions in those forms that co-chromatograph with synthetic somatostatin-14 and somatostatin-28. These results indicate that CSH has a generalized, rapid, and largely reversible effect in depleting SLI from the rat CNS

  2. Somatostatin-based radiotherapy with [90Y-DOTA]-TOC in neuroendocrine tumors: long-term outcome of a phase I dose escalation study.

    Science.gov (United States)

    Marincek, Nicolas; Jörg, Ann-Catherine; Brunner, Philippe; Schindler, Christian; Koller, Michael T; Rochlitz, Christoph; Müller-Brand, Jan; Maecke, Helmut R; Briel, Matthias; Walter, Martin A

    2013-01-15

    We describe the long-term outcome after clinical introduction and dose escalation of somatostatin receptor targeted therapy with [90Y-DOTA]-TOC in patients with metastasized neuroendocrine tumors. In a clinical phase I dose escalation study we treated patients with increasing [90Y-DOTA]-TOC activities. Multivariable Cox regression and competing risk regression were used to compare efficacy and toxicities of the different dosage protocols. Overall, 359 patients were recruited; 60 patients were enrolled for low dose (median: 2.4 GBq/cycle, range 0.9-7.8 GBq/cycle), 77 patients were enrolled for intermediate dose (median: 3.3 GBq/cycle, range: 2.0-7.4 GBq/cycle) and 222 patients were enrolled for high dose (median: 6.7 GBq/cycle, range: 3.7-8.1 GBq/cycle) [90Y-DOTA]-TOC treatment. The incidences of hematotoxicities grade 1-4 were 65.0%, 64.9% and 74.8%; the incidences of grade 4/5 kidney toxicities were 8.4%, 6.5% and 14.0%, and the median survival was 39 (range: 1-158) months, 34 (range: 1-118) months and 29 (range: 1-113) months. The high dose protocol was associated with an increased risk of kidney toxicity (Hazard Ratio: 3.12 (1.13-8.59) vs. intermediate dose, p = 0.03) and a shorter overall survival (Hazard Ratio: 2.50 (1.08-5.79) vs. low dose, p = 0.03). Increasing [90Y-DOTA]-TOC activities may be associated with increasing hematological toxicities. The dose related hematotoxicity profile of [90Y-DOTA]-TOC could facilitate tailoring [90Y-DOTA]-TOC in patients with preexisting hematotoxicities. The results of the long-term outcome suggest that fractionated [90Y-DOTA]-TOC treatment might allow to reduce renal toxicity and to improve overall survival. (ClinicalTrials.gov number NCT00978211).

  3. Ga-66 labeled somatostatin analogue DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide as a potential agent for positron emission tomography imaging and receptor mediated internal radiotherapy of somatostatin receptor positive tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ugur, Oemer E-mail: ougur@hacettepe.edu.tr; Kothari, Paresh J.; Finn, Ronald D.; Zanzonico, Pat; Ruan, Shutian; Guenther, Ilonka; Maecke, Helmut R.; Larson, Steven M

    2002-02-01

    Radionuclide labeled somatostatin analogues selectively target somatostatin receptor (SSTR)-expressing tumors as a basis for diagnosis and treatment of these tumors. Recently, a DOTA-functionalized somatostatin analogue, DOTATOC (DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide) has been developed. This compound has been shown to be superior to the other somatostatin analogues as indicated by its uniquely high tumor-to-non-target tissue ratio. DOTATOC can be labeled with a variety of radiometals including gallium radioisotopes. Gallium-66 is a positron emitting radionuclide (T{sub 1/2} =9.5 hr; {beta}{sup +}=56%), that can be produced in carrier free form by a low-beam energy cyclotron. In this study we investigated SSTR targeting characteristics of {sup 66}Ga-DOTATOC in AR42J rat pancreas tumor implanted nude mice as a potential agent for diagnosis and receptor-mediated internal radiotherapy of SSTR-expressing tumors. We compared our results with {sup 67}Ga- and {sup 68}Ga- labeled DOTATOC. The radiolabeling procedure gave labeling yield ranged from 85-95% and radiochemical and chemical purity was >95%. In-vitro competitive binding curves and in-vivo competitive displacement studies with an excess of unlabeled peptide indicates that there is specific binding of the radioligand to SSTR. Animal biodistribution data and serial microPET{sup TM} images demonstrated rapid tumor uptake and rapid clearance from the blood and all tissues except kidney. Maximum % ID/g values for tumor were 10.0{+-}0.7, 13.2{+-}2.1 and 9.8{+-}1.5 for {sup 66}Ga-, {sup 67}Ga-, and {sup 68}Ga-DOTATOC, respectively. Calculated tumor, kidney and bone marrow doses for {sup 66}Ga-DOTATOC based on biodistribution data were 178, 109 and 1.2 cGy/MBq, respectively. We conclude that {sup 66}Ga labeled DOTATOC can be used for PET diagnosis and quantitative imaging-based dosimetry of SSTR positive tumors. {sup 66}Ga-DOTATOC may also be used in higher doses for ablation of these tumors. However, kidney is the

  4. Regulation of ATP-sensitive K+ channels in insulinoma cells: Activation by somatostatin and protein kinase C and the role of cAMP

    International Nuclear Information System (INIS)

    De Weille, J.R.; Schmid-Antomarchi, H.; Fosset, M.; Lazdunski, M.

    1989-01-01

    The actions of somatostatin and of the phorbol ester 4β-phorbol 12-myristate 13-acetate (PMA) were studied in rat insulinoma (RINm5F) cells by electrophysiological and 86 Rb + flux techniques. Both PMA and somatostatin hyperpolarize insulinoma cells by activating ATP-sensitive K + channels. The presence of intracellular GTP is required for the somatostatin effects. PMA- and somatostatin-induced hyperpolarization and channel activity are inhibited by the sulfonylurea glibenclamide. Glibenclamide-sensitive 86 Rb + efflux from insulinoma cells is stimulated by somatostatin in a dose-dependent manner (half maximal effect at 0.7 nM) and abolished by pertussis toxin pretreatment. Mutual roles of a GTP-binding protein, of protein kinase C, and of cAMP in the regulation of ATP-sensitive K + channels are discussed

  5. Somatostatin-based radiotherapy with [90Y-DOTA]-TOC in neuroendocrine tumors: long-term outcome of a phase I dose escalation study

    Directory of Open Access Journals (Sweden)

    Marincek Nicolas

    2013-01-01

    Full Text Available Abstract Background We describe the long-term outcome after clinical introduction and dose escalation of somatostatin receptor targeted therapy with [90Y-DOTA]-TOC in patients with metastasized neuroendocrine tumors. Methods In a clinical phase I dose escalation study we treated patients with increasing [90Y-DOTA]-TOC activities. Multivariable Cox regression and competing risk regression were used to compare efficacy and toxicities of the different dosage protocols. Results Overall, 359 patients were recruited; 60 patients were enrolled for low dose (median: 2.4 GBq/cycle, range 0.9-7.8 GBq/cycle, 77 patients were enrolled for intermediate dose (median: 3.3 GBq/cycle, range: 2.0-7.4 GBq/cycle and 222 patients were enrolled for high dose (median: 6.7 GBq/cycle, range: 3.7-8.1 GBq/cycle [90Y-DOTA]-TOC treatment. The incidences of hematotoxicities grade 1–4 were 65.0%, 64.9% and 74.8%; the incidences of grade 4/5 kidney toxicities were 8.4%, 6.5% and 14.0%, and the median survival was 39 (range: 1–158 months, 34 (range: 1–118 months and 29 (range: 1–113 months. The high dose protocol was associated with an increased risk of kidney toxicity (Hazard Ratio: 3.12 (1.13-8.59 vs. intermediate dose, p = 0.03 and a shorter overall survival (Hazard Ratio: 2.50 (1.08-5.79 vs. low dose, p = 0.03. Conclusions Increasing [90Y-DOTA]-TOC activities may be associated with increasing hematological toxicities. The dose related hematotoxicity profile of [90Y-DOTA]-TOC could facilitate tailoring [90Y-DOTA]-TOC in patients with preexisting hematotoxicities. The results of the long-term outcome suggest that fractionated [90Y-DOTA]-TOC treatment might allow to reduce renal toxicity and to improve overall survival. (ClinicalTrials.gov number NCT00978211.

  6. Somatostatin-based radiotherapy with [90Y-DOTA]-TOC in neuroendocrine tumors: long-term outcome of a phase I dose escalation study

    Science.gov (United States)

    2013-01-01

    Background We describe the long-term outcome after clinical introduction and dose escalation of somatostatin receptor targeted therapy with [90Y-DOTA]-TOC in patients with metastasized neuroendocrine tumors. Methods In a clinical phase I dose escalation study we treated patients with increasing [90Y-DOTA]-TOC activities. Multivariable Cox regression and competing risk regression were used to compare efficacy and toxicities of the different dosage protocols. Results Overall, 359 patients were recruited; 60 patients were enrolled for low dose (median: 2.4 GBq/cycle, range 0.9-7.8 GBq/cycle), 77 patients were enrolled for intermediate dose (median: 3.3 GBq/cycle, range: 2.0-7.4 GBq/cycle) and 222 patients were enrolled for high dose (median: 6.7 GBq/cycle, range: 3.7-8.1 GBq/cycle) [90Y-DOTA]-TOC treatment. The incidences of hematotoxicities grade 1–4 were 65.0%, 64.9% and 74.8%; the incidences of grade 4/5 kidney toxicities were 8.4%, 6.5% and 14.0%, and the median survival was 39 (range: 1–158) months, 34 (range: 1–118) months and 29 (range: 1–113) months. The high dose protocol was associated with an increased risk of kidney toxicity (Hazard Ratio: 3.12 (1.13-8.59) vs. intermediate dose, p = 0.03) and a shorter overall survival (Hazard Ratio: 2.50 (1.08-5.79) vs. low dose, p = 0.03). Conclusions Increasing [90Y-DOTA]-TOC activities may be associated with increasing hematological toxicities. The dose related hematotoxicity profile of [90Y-DOTA]-TOC could facilitate tailoring [90Y-DOTA]-TOC in patients with preexisting hematotoxicities. The results of the long-term outcome suggest that fractionated [90Y-DOTA]-TOC treatment might allow to reduce renal toxicity and to improve overall survival. Trial registration ClinicalTrials.gov number:NCT00978211 PMID:23320604

  7. DOTA-derivatives of octreotide dicarba-analogues with high affinity for somatostatin sst2,5 receptors

    Science.gov (United States)

    Pratesi, Alessandro; Ginanneschi, Mauro; Lumini, Marco; Papini, Anna M.; Novellino, Ettore; Brancaccio, Diego; Carotenuto, Alfonso

    2017-02-01

    In vivo somatostatin receptor scintigraphy is a valuable method for the visualization of human endocrine tumours and their metastases. In fact, peptide ligands of somatostatin receptors (sst’s) conjugated with chelating agents are in clinical use. We have recently developed octreotide dicarba-analogues, which show interesting binding profiles at sst’s. In this context, it was mandatory to explore the possibility that our analogues could maintain their activity also upon conjugation with DOTA. In this paper, we report and discuss the synthesis, binding affinity and conformational preferences of three DOTA-conjugated dicarba-analogues of octreotide. Interestingly, two conjugated analogues exhibited nanomolar affinities on sst2 and sst5 somatostatin receptor subtypes.

  8. Radioimmunoassay of somatostatin: methodological problems and physiological investigations

    International Nuclear Information System (INIS)

    Penman, E.; Wass, J.A.H.

    1981-01-01

    Somatostatin, a tetradecapeptide, has a wide distribution throughout the central nervous system and the gastrointestinal tract and a broad spectrum of biological actions. In order to investigate its various physiological roles in man, a radioimmunoassay was developed for somatostatin in human blood plasma, which is described here. This RIA was used to investigate possible factors influencing somatostatin secretion. Changes in somatin levels produced by changes in insulin, glucagon and growth hormone levels were studied via the response of plasma immunoreactive somatostatin to hormonal stimuli in normal man. The influence of fasting and food consumption was studied; and the site of origin of circulating immunoreactive somatostatin was investigated in patients. (Auth.)

  9. Calcitonin gene-related peptide and somatostatin releases correlated with the area under the lafutidine concentration-time curve in human plasma.

    Science.gov (United States)

    Ikawa, K; Shimatani, T; Azuma, Y; Inoue, M; Morikawa, N

    2006-08-01

    To examine the effects of the histamine H(2)-receptor antagonist, lafutidine, at clinical dosage (10 mg tablet after a standardized meal) on plasma levels of the gastrointestinal peptides, calcitonin gene-related peptide (CGRP), somatostatin and gastrin. Six healthy male volunteers ate a standardized meal, and received either lafutidine orally at a dose of 10 mg or water only (control). Blood samples were taken before and up to 4 h after the drug administration. Plasma lafutidine concentrations were determined by high pressure liquid chromatography. Pharmacokinetic analysis of lafutidine was performed using one-compartmental model. The levels of immunoreactive substances of plasma CGRP, somatostatin and gastrin were measured by enzyme immunoassay, and the amount of peptide release was calculated by the trapezoidal method. Lafutidine significantly increased plasma CGRP levels at 1, 1.5, 2.5 and 4 h and the total amount of CGRP release (192 +/- 14.0 pg.h/mL) compared with the control group (128 +/- 21.5 pg.h/mL). Lafutidine significantly increased the plasma somatostatin levels at 1 and 1.5 h, and the total amount of somatostatin released (107 +/- 18.2 pg.h/mL) compared with the control (78.4 +/- 7.70 pg.h/mL). The area under the drug concentration-time curve (AUC) from 0 to 4 h after administration correlated well with the Delta-CGRP and Delta-somatostatin release but not with total amount of gastrin released. However, plasma gastrin levels were significantly elevated at 1.5 h after drug administration. Lafutidine at clinical dosage increases plasma CGRP and the somatostatin. The amounts released correlated with the AUC of lafutidine in humans. These results suggest that the increased release of CGRP and somatostatin may contribute to its gastroprotective and anti-acid secretory effect.

  10. Somatostatin in the caudal spinal cord

    DEFF Research Database (Denmark)

    Schrøder, H D

    1984-01-01

    . In all of these regions somatostatin-positive cell bodies were also observed. In the intermediate gray matter stained terminals were present around the central canal in a varying number. The most prominent stainability was found in the lumbosacral transition zone. Many terminals were also observed...... was particularly low in the motoneuron neuropil. However, a dense somatostatin network was found in the sixth lumbar segment in relation to the neurons in Onuf's nucleus X complex, the nucleus that innervates the small pelvic muscles including the striated sphincters. It is concluded that somatostatin, besides...

  11. Purification of a putative brain somatostatin receptor

    International Nuclear Information System (INIS)

    He, Haitao; Johnson, K.; Thermos, K.; Reisine, T.

    1989-01-01

    The brain somatostatin receptor was purified by affinity chromatographic techniques. A protein of 60 kDa could be purified from rat brain. The protein was eluted from a [D-Trp 8 ]SRIF affinity column with either sodium acetate (pH 5.5) or free [D-Trp 8 ]SRIF. The binding of the protein to the affinity column was prevented by free [D-Trp 8 ]SRIF or the stable SRIF analogue SMS 201-996 but not by the inactive somatostatin 28-(1-14). The purified receptor could be covalently labeled by the 125 I-labeled SRIF analogue CGP 23996. Excess [D-Trp 8 ]SRIF blocked the binding of 125 I-labeled CGP 23996 to the purified receptor, but somatostatin 28-(1-14) did not affect the binding. A 60-kDa protein was also purified from the anterior pituitary cell line AtT-20, which has a high expression of SRIF receptors. In contrast, no 60-kDa protein could be purified from CHO cells, which have no detectable SRIF receptors. These findings present evidence for the purification of the SRIF receptor

  12. Iodination and stability of somatostatin analogues: comparison of iodination techniques. A practical overview.

    Science.gov (United States)

    de Blois, Erik; Chan, Ho Sze; Breeman, Wouter A P

    2012-01-01

    For iodination ((125/127)I) of tyrosine-containing peptides, chloramin-T, Pre-Coated Iodo-Gen(®) tubes and Iodo-Beads(®) (Pierce) are commonly used for in vitro radioligand investigations and there have been reliant vendors hereof for decades. However, commercial availability of these radio-iodinated peptides is decreasing. For continuation of our research in this field we investigated and optimized (radio-)iodination of somatostatin analogues. In literature, radioiodination using here described somatostatin analogues and iodination techniques are described separately. Here we present an overview, including High Performance Liquid Chromatography (HPLC) separation and characterisation by mass spectrometry, to obtain mono- and di-iodinated analogues. Reaction kinetics of (125/127)I iodinated somatostatin analogues were investigated as function of reaction time and concentration of reactants, including somatostatin analogues, iodine and oxidizing agent. To our knowledge, for the here described somatostatin analogues, no (127)I iodination and optimization are described. (Radio-)iodinated somatostatin analogues could be preserved with a >90% radiochemical purity for 1 month after reversed phase HPLC-purification.

  13. Active postoperative acromegaly: sustained remission after discontinuation of somatostatin analogues

    Directory of Open Access Journals (Sweden)

    Cristina Alvarez-Escola

    2016-11-01

    Full Text Available In patients with active acromegaly after pituitary surgery, somatostatin analogues are effective in controlling the disease and can even be curative in some cases. After treatment discontinuation, the likelihood of disease recurrence is high. However, a small subset of patients remains symptom-free after discontinuation, with normalized growth hormone (GH and insulin-like growth factor (IGF1 levels. The characteristics of patients most likely to achieve sustained remission after treatment discontinuation are not well understood, although limited evidence suggests that sustained remission is more likely in patients with lower GH and IGF1 levels before treatment withdrawal, in those who respond well to low-dose treatment, in those without evidence of adenoma on an MRI scan and/or in patients who receive long-term treatment. In this report, we describe the case of a 56-year-old female patient treated with lanreotide Autogel for 11 years. Treatment was successfully discontinued, and the patient is currently disease-free on all relevant parameters (clinical, biochemical and tumour status. The successful outcome in this case adds to the small body of literature suggesting that some well-selected patients who receive long-term treatment with somatostatin analogues may achieve sustained remission.

  14. Cell-to-cell communication and cellular environment alter the somatostatin status of delta cells

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Catriona, E-mail: catriona.kelly@qub.ac.uk [SAAD Centre for Pharmacy and Diabetes, School of Biomedical Sciences, University of Ulster, Coleraine (United Kingdom); Flatt, Peter R.; McClenaghan, Neville H. [SAAD Centre for Pharmacy and Diabetes, School of Biomedical Sciences, University of Ulster, Coleraine (United Kingdom)

    2010-08-20

    Research highlights: {yields} TGP52 cells display enhanced functionality in pseudoislet form. {yields} Somatostatin content was reduced, but secretion increased in high glucose conditions. {yields} Cellular interactions and environment alter the somatostatin status of TGP52 cells. -- Abstract: Introduction: Somatostatin, released from pancreatic delta cells, is a potent paracrine inhibitor of insulin and glucagon secretion. Islet cellular interactions and glucose homeostasis are essential to maintain normal patterns of insulin secretion. However, the importance of cell-to-cell communication and cellular environment in the regulation of somatostatin release remains unclear. Methods: This study employed the somatostatin-secreting TGP52 cell line maintained in DMEM:F12 (17.5 mM glucose) or DMEM (25 mM glucose) culture media. The effect of pseudoislet formation and culture medium on somatostatin content and release in response to a variety of stimuli was measured by somatostatin EIA. In addition, the effect of pseudoislet formation on cellular viability (MTT and LDH assays) and proliferation (BrdU ELISA) was determined. Results: TGP52 cells readily formed pseudoislets and showed enhanced functionality in three-dimensional form with increased E-cadherin expression irrespective of the culture environment used. However, culture in DMEM decreased cellular somatostatin content (P < 0.01) and increased somatostatin secretion in response to a variety of stimuli including arginine, calcium and PMA (P < 0.001) when compared with cells grown in DMEM:F12. Configuration of TGP52 cells as pseudoislets reduced the proliferative rate and increased cellular cytotoxicity irrespective of culture medium used. Conclusions: Somatostatin secretion is greatly facilitated by cell-to-cell interactions and E-cadherin expression. Cellular environment and extracellular glucose also significantly influence the function of delta cells.

  15. Cell-to-cell communication and cellular environment alter the somatostatin status of delta cells

    International Nuclear Information System (INIS)

    Kelly, Catriona; Flatt, Peter R.; McClenaghan, Neville H.

    2010-01-01

    Research highlights: → TGP52 cells display enhanced functionality in pseudoislet form. → Somatostatin content was reduced, but secretion increased in high glucose conditions. → Cellular interactions and environment alter the somatostatin status of TGP52 cells. -- Abstract: Introduction: Somatostatin, released from pancreatic delta cells, is a potent paracrine inhibitor of insulin and glucagon secretion. Islet cellular interactions and glucose homeostasis are essential to maintain normal patterns of insulin secretion. However, the importance of cell-to-cell communication and cellular environment in the regulation of somatostatin release remains unclear. Methods: This study employed the somatostatin-secreting TGP52 cell line maintained in DMEM:F12 (17.5 mM glucose) or DMEM (25 mM glucose) culture media. The effect of pseudoislet formation and culture medium on somatostatin content and release in response to a variety of stimuli was measured by somatostatin EIA. In addition, the effect of pseudoislet formation on cellular viability (MTT and LDH assays) and proliferation (BrdU ELISA) was determined. Results: TGP52 cells readily formed pseudoislets and showed enhanced functionality in three-dimensional form with increased E-cadherin expression irrespective of the culture environment used. However, culture in DMEM decreased cellular somatostatin content (P < 0.01) and increased somatostatin secretion in response to a variety of stimuli including arginine, calcium and PMA (P < 0.001) when compared with cells grown in DMEM:F12. Configuration of TGP52 cells as pseudoislets reduced the proliferative rate and increased cellular cytotoxicity irrespective of culture medium used. Conclusions: Somatostatin secretion is greatly facilitated by cell-to-cell interactions and E-cadherin expression. Cellular environment and extracellular glucose also significantly influence the function of delta cells.

  16. Preparation and biological evaluation of [(99m)Tc/EDDA/Tricine/HYNIC(0), BzThi(3)]-octreotide for somatostatin receptor-positive tumor imaging.

    Science.gov (United States)

    Erfani, Mostafa; Shafiei, Mohammad; Mazidi, Mohammad; Goudarzi, Mostafa

    2013-04-01

    Somatostatin-derived analogues play an important role in the diagnosis and treatment of neuroendocrine tumors. The aim of this study was to evaluate a new somatostatin analogue designed for labeling with (99m)Tc: [6-hydrazinopyridine-3-carboxylic acid (HYNIC(0)), β-(3-benzothienyl)-Ala (BzThi(3))]-octreotide ([HYNIC]-BOC), using ethylenediamine-N,N'-diacetic acid (EDDA) and tricine as coligands. Synthesis was performed on a solid phase using a standard Fmoc strategy. The HYNIC-peptide conjugate was radiolabeled with (99m)Tc and characterized by ITLC and high-performance liquid chromatography (HPLC). In vitro studies were carried out in sstr2 expressing AR4-2J cell lines. In vivo distribution studies were performed in rats bearing the AR4-2J tumor. The radiolabeled complex could be prepared at high-specific activities and >95% radiochemical yield as determined by HPLC. The peptide conjugate showed high-affinity binding for sstr2. The radioligand showed high and specific internalization into AR4-2J cells (18.19%±0.21% at 4 hours). In vivo distribution studies in rats bearing tumor have shown a receptor-specific uptake of radioactivity in somatostatin receptor-positive organs. After 4 hours, uptake in the AR4-2J tumor was 1.71%±0.36% injected dose per gram tissue (%ID/g). These data show that [(99m)Tc/EDDA/Tricine/HYNIC(0), BzThi(3)]-octreotide is a specific radioligand for the somatostatin receptor-positive tumors and is a suitable candidate for clinical studies.

  17. Preclinical evaluation of somatostatin analogs bearing two macrocyclic chelators for high specific activity labeling with radiometals

    International Nuclear Information System (INIS)

    Storch, D.; Schmitt, J.S.; Waldherr, C.; Maecke, H.R.; Waser, B.; Reubi, J.C.

    2007-01-01

    Radiometallated analogues of the regulatory peptide somatostatin are of interest in the in vivo localization and targeted radiotherapy of somatostatin receptor-overexpressing tumors. An important aspect of their use in vivo is a fast and efficient labeling (complexation) protocol for radiometals along with a high specific activity. We describe in this manuscript synthetic methods for the coupling of two chelators (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid = DOTA) to the bioactive peptide [Tyr 3 ,Thr 8 ]-octreotide (TATE) in order to increase the specific activity (radioactivity in Bq per mole peptide). The full chelator-linker-peptide conjugate was assembled on solid support using standard Fmoc chemistry. Two DOTA-chelators were linked to the peptide using lysine or N,N'-bis(3-aminopropyl)-glycine (Apg); in addition, pentasarcosine (Sar 5 ) was used as a spacer between the chelators and the peptide to probe its influence on biology and pharmacology. Complexation rates with In 3+ and Y 3+ salts and the corresponding radiometals were high, the bis-DOTA-derivatives showed higher complexation rates and gave higher specific activity than DOTA-TATE. Pharmacological and biological data of the complexed molecules did not show significant differences if compared to the parent peptide [ 111/nat In-DOTA]-TATE except for [( 111/nat In-DOTA) 2 -Apg]-TATE which showed a lower binding affinity and rate of internalization into tumor cells. The biodistribution of [( 111/nat In-DOTA)-Lys( 111/nat In-DOTA)]-TATE in the rat tumor model (AR4-2J) showed a high and specific (as shown by a blocking experiment) tracer uptake in somatostatin receptor-positive tissue but a lower tumor uptake compared to [ 111/nat In-DOTA]-TATE. (orig.)

  18. Regulation of somatostatin release in the nervous system of the rat

    International Nuclear Information System (INIS)

    Sheppard, M.

    1979-08-01

    This thesis represents the work done to study the release of somatostatin from the rat central nervous system in vitro, providing some evidence for a physiological role for somatostatin. Somatostatin was measured by a sensitive and specific radioimmunoassay devoloped in the laboratory. Chapter 2 reviews the literature on hypothalamic peptides and control of an anterior pituitary function, somatostatin, other central nervous system peptides and neurosecretion. Chapter 3 describes the central nervous system tissue dissection technique, the radioimmunoassay for somatostatin and the tissue levels of somatostatin immunoreactivity in different areas of the central nervous system. Chapter 4 deals with the release of immunoreactive somatostatin from incubated rat hypothalamus in vitro and the influence of other hormones and neuropeptides on this release. Chapter 5 describes the preparation of isolated nerve endings (synaptosomes) from four different areas of rat brain, the localisation of somatostatin to the synaptosome fraction of brain homogenates and the release of somatostatin from these synaptosomes. Chapter 6 deals with the release of somatostatin from incubated rat spinal cord in vitro. Chapter 7 presents the results of the characterisation of released immunoreactive material, the technique utilised being serial dilution of immunoreactive material and comparison to the standard curve, Sephadex gel chromatography, affinity chromatography, and the effect of released immunoreactive somatostatin on growth hormone release from perifused hemipituitaries in vitro, i.e. biological activity. Chapter 8 provides a summary of the main conclusions reached in this study and is followed by the Appendix describing chemical and biochemical methods, histological techniques, and statistical methods

  19. Truncated somatostatin receptor 5 may modulate therapy response to somatostatin analogues--Observations in two patients with acromegaly and severe headache

    DEFF Research Database (Denmark)

    Marina, Djordje; Burman, Pia; Klose, Marianne

    2015-01-01

    BACKGROUND: Somatotropinomas have unique "fingerprints" of somatostatin receptor (sst) expression, which are targets in treatment of acromegaly with somatostatin analogues (SSAs). However, a significant expression of sst is not always related to the biochemical response to SSAs. Headache is a com...

  20. The radioimmunoassay and physiology of somatostatin in the pancreas and gastrointestinal tract.

    Science.gov (United States)

    McIntosh, C; Arnold, R

    1978-05-01

    Radioimmunoassays for somatostain have demonstrated that high concentrations of the polypeptide are present in the pancreas and gastrointestinal tract of a number of species. Although measurement in tissue extracts is relatively unproblematic, detection and characterization of somatostatin-like material in plasma has proved technically difficult. Studies of pancreatic somatostatin release in vitro suggest a possible function in the regulation of islet hormone secretion, but the mode of action remains to be elucidated. Although, at present, no clinical relevance can be attributed to the somatostain radioimmunoassay reports of somatostatin secreting tumors and changes in stomach tissue content in patients with ulcer disease indicate a contributory role in the pathophysiology of certain disease states.

  1. Diagnostic value of somatostatin receptor scintigraphy in patients with intracranial tumours. Diagnostische Wertigkeit der Somatostatin-Rezeptor-Szintigraphie bei Patienten mit intrakraniellen Raumforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Luyken, C. (Klinik fuer Neurochirurgie, Koeln Univ. (Germany)); Hildebrandt, G. (Klinik fuer Neurochirurgie, Koeln Univ. (Germany)); Scheidhauer, K. (Klinik fuer Nuklearmedizin, Koeln Univ. (Germany)); Kirsch, B. (Anatomisches Inst., Kiel Univ. (Germany))

    1993-12-01

    The aim of the study was to detect the SR binding sites in intracranial tumours and to evaluate the benefit of SRS in pre- and postoperative diagnostics. 86 patients with 94 intracranial tumours (39 meningiomas, 18 pituitary adenomas, 11 gliomas grade 3 or 4, 8 gliomas grade 2, 5 neurinomas, 5 intracranial metastases, 4 tumours of the orbit, 2 neurofibromas, 1 brain abscess and 1 cystic lesion) were examined. [sup 111]In-octreotide was injected i.v. as 10 [mu]g or 20 [mu]g bolus, corresponding to 110 or 220 MBq (3 or 6 mCi). Gamma-camera images and SPECT were obtained 3-6 h and 24 h post injection. The scintigraphic evaluation was performed without knowledge of CT and MRI results. The histological classification corresponded to the WHO grading system. Somatostatin binding sites were detected in vito using somatostatin-gold conjugates. All patients with meningiomas showed a high focal tracer uptake corresponding to SR binding sites in vitro, whereas only in 50% of the pituitary adenomas SRS was positive. Neurinomas did not show any tracer uptake. In patients with gliomas with disturbed blood-brain-barrier positive tracer uptake was detected, while none of the gliomas with intact blood-brain-barrier could be visualized by SRS but showed somatostatin binding sites in vitro. In intracranial metastases a local tracer uptake was detected in vivo. In vitro 3 of 4 cases showed somatostatin binding sites. In 2 cases extracranial tracer uptake showed the primary tumour and metastases of the lymphnodes. Somatostatin receptor scintigraphy can help to detect or to exclude meningiomas especially in the cerebellopontine angle or in the orbit. In intracranial metastases SRS may point to the primary tumour or other metastases. In all other intracranial tumours receptor scintigraphy provides no clinical relevant information. (orig./MG)

  2. Primary treatment of acromegaly with high-dose lanreotide: a case series

    Directory of Open Access Journals (Sweden)

    Cordes Uwe

    2010-03-01

    Full Text Available Abstract Introduction The first-line treatment for acromegaly is transsphenoidal surgery. In approximately 50% of patients, however, a cure is not possible with surgery and alternatives are needed. Somatostatin analog therapy is the recommended first-line treatment in patients with such cases. Here we provide the first report of a high-dose lanreotide primary therapy in patients with acromegaly. Case presentation Six patients who were not suitable for surgery were given 60 mg of lanreotide (Autogel® every four weeks. All patients were German nationals and Caucasian. When the response of our patients was unsatisfactory, the dose was increased sequentially to 90 mg every four weeks, 120 mg every four weeks, 120 mg every three weeks and 180 mg every three weeks. Treatment duration was 12 to 24 months. In all cases, the lanreotide dose was 120 mg every 4 weeks or higher. In five of our patients, growth hormone (GH levels were successfully reduced (in three patients GH Tumor shrinkage or degeneration was observed in the five responding patients. No drug-related adverse events were noted. Conclusions These results suggest that lanreotide at high doses of 120 mg every four weeks or more is an effective first-line therapy for patients with acromegaly that surgery alone cannot treat.

  3. Somatostatin receptor scintigraphy in endocrine ophthalmopathy; Somatostatin-Rezeptor-Szintigraphie bei endokriner Orbitopathie

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, M. [Klinik und Poliklinik fuer Nuklearmedizin, Univ. Mainz (Germany); Kahaly, G. [3. Medizinische Klinik und Poliklinik, Innere Medizin - Endokrinologie, Univ. Mainz (Germany); Muehlbach, A. [3. Medizinische Klinik und Poliklinik, Innere Medizin - Endokrinologie, Univ. Mainz (Germany); Bockisch, A. [Klinik und Poliklinik fuer Nuklearmedizin, Univ. Mainz (Germany); Beyer, J. [3. Medizinische Klinik und Poliklinik, Innere Medizin - Endokrinologie, Univ. Mainz (Germany); Hahn, K. [Klinik und Poliklinik fuer Nuklearmedizin, Univ. Mainz (Germany)

    1994-12-01

    Somatostatin receptor scintigraphy with {sup 111}In-labeled octreotide proves to be a very sensitive diagnostic tool for evaluation of inflammative activity in endocrine ophthalmopathy (EO). The results of somatostatin receptor scintigraphy (SRS) in 40 patients with EO show a high orbital accumulation of {sup 111}In-octreotide in clinically active EO (4h-median/orbit-brain-ratio: 12.6; controls 4h-median: 5.8) Patients with clinically inactive EO (4h-median: 7.1) show a similar orbital accumulation of radioactivity compared to controls. 5 patients with active orbital myositis also revealed an even higher orbital accumulation of radioactivity (4h-median: 42.3). The diagnostic value of SRS lies in its ability to act as a measure of inflammation and an be useful as an activity parameter when planning therapeutic procedure as well as for EO follow-up. The results in patients with orbital myositis nevertheless do not permit a differential diagnosis with this method. The therapeutic value of {sup 111}In-octreotide in Graves` disease has yet to be established. (orig.) [Deutsch] Die Somatostatin-Rezeptor-Szintigraphie (SRS) mit dem {sup 111}Indium-markierten Somatostatinanalogon Octreotid stellt ein sensitives Verfahren zur Einschaetzung der entzuendlichen Aktivitaet bei endokriner Orbitopathie (EO) dar. Die Untersuchungen an 40 Patienten mit EO ergaben eine im Vergleich zur Kontrollgruppe signifikant hoehere orbitale Octreotidanreicherung bei klinisch aktiver Erkrankung (4h-Median/Orbita-Hirn-Quotient: 12,6; Kontrollgruppe 4h-Median: 5,8; p=0,0032). Patienten mit klinisch nicht aktiver Erkrankung (4h-Median: 7,1) unterschieden sich bezueglich der orbitalen Octreotidanreicherung nicht wesentlich von der Kontrollgruppe. Auch 5 Patienten mit florider orbitaler Myositis zeigten eine deutlich gesteigerte orbitale Aktivitaetsanreicherung (4h-Median: 42,3). Der diagnostische Nutzen der SRS liegt somit in ihrer Eigenschaft als Aktivitaets- und Entzuendungsparameter und kann mit

  4. Scintigraphy with labelled analogues of the somatostatin

    International Nuclear Information System (INIS)

    Duet, M.; Ajzenberg, C.; Warnet, A.; Mundler, O.

    1998-01-01

    The receptors of the somatostatin have been localized in a big number of tumors, whom a great number are neuro-endocrine tumors. However, some tumors that have not this differentiation (breast cancer, lymphomas, cerebral tumors) possess them as well. Analogues of somatostatin, labelled with isotopes having a gamma emission, allow from now their detection in vivo. (N.C.)

  5. Pertussis toxin modifies the characteristics of both the inhibitory GTP binding proteins and the somatostatin receptor in anterior pituitary tumor cells

    International Nuclear Information System (INIS)

    Mahy, N.; Woolkalis, M.; Thermos, K.; Carlson, K.; Manning, D.; Reisine, T.

    1988-01-01

    The effects of pertussis toxin treatment on the characteristics of somatostatin receptors in the anterior pituitary tumor cell line AtT-20 were examined. Pertussis toxin selectively catalyzed the ADP ribosylation of the alpha subunits of the inhibitory GTP binding proteins in AtT-20 cells. Toxin treatment abolished somatostatin inhibition of forskolin-stimulated adenylyl cyclase activity and somatostatin stimulation of GTPase activity. To examine the effects of pertussis toxin treatment on the characteristics of the somatostatin receptor, the receptor was labeled by the somatostatin analog [125I]CGP 23996. [125I]CGP 23996 binding to AtT-20 cell membranes was saturable and within a limited concentration range was to a single high affinity site. Pertussis toxin treatment reduced the apparent density of the high affinity [125I]CGP 23996 binding sites in AtT-20 cell membranes. Inhibition of [125I]CGP 23996 binding by a wide concentration range of CGP 23996 revealed the presence of two binding sites. GTP predominantly reduced the level of high affinity sites in control membranes. Pertussis toxin treatment also diminished the amount of high affinity sites. GTP did not affect [125I]CGP 23996 binding in the pertussis toxin-treated membranes. The high affinity somatostatin receptors were covalently labeled with [125I] CGP 23996 and the photoactivated crosslinking agent n-hydroxysuccinimidyl-4-azidobenzoate. No high affinity somatostatin receptors, covalently bound to [125I]CGP 23996, were detected in the pertussis toxin-treated membranes. These results are most consistent with pertussis toxin uncoupling the inhibitory G proteins from the somatostatin receptor thereby converting the receptor from a mixed population of high and low affinity sites to only low affinity receptors

  6. Critical role of somatostatin receptor 2 in the vulnerability of the central noradrenergic system

    DEFF Research Database (Denmark)

    Ádori, Csaba; Glück, Laura; Barde, Swapnali

    2015-01-01

    Alzheimer’s disease and other age-related neurodegenerative disorders are associated with deterioration of the noradrenergic locus coeruleus (LC), a probable trigger for mood and memory dysfunction. LC noradrenergic neurons exhibit particularly high levels of somatostatin binding sites. This is n......Alzheimer’s disease and other age-related neurodegenerative disorders are associated with deterioration of the noradrenergic locus coeruleus (LC), a probable trigger for mood and memory dysfunction. LC noradrenergic neurons exhibit particularly high levels of somatostatin binding sites...... morphometry and mRNA profiling in a cohort of Alzheimer’s and age-matched control brains in combination with genetic models of somatostatin receptor deficiency to establish causality between defunct somatostatin signalling and noradrenergic neurodegeneration. In Alzheimer’s disease, we found significantly....../IV and onwards, i.e., a process preceding advanced Alzheimer’s pathology. The loss of SSTR2 transcripts in the LC neurons appeared selective, since tyrosine hydroxylase, dopamine β-hydroxylase, galanin or galanin receptor 3 mRNAs remained unchanged. We modeled these pathogenic changes in Sstr2 −/− mice and...

  7. Role of somatostatin receptor-2 in gentamicin-induced auditory hair cell loss in the Mammalian inner ear.

    Directory of Open Access Journals (Sweden)

    Yves Brand

    Full Text Available Hair cells and spiral ganglion neurons of the mammalian auditory system do not regenerate, and their loss leads to irreversible hearing loss. Aminoglycosides induce auditory hair cell death in vitro, and evidence suggests that phosphatidylinositol-3-kinase/Akt signaling opposes gentamicin toxicity via its downstream target, the protein kinase Akt. We previously demonstrated that somatostatin-a peptide with hormone/neurotransmitter properties-can protect hair cells from gentamicin-induced hair cell death in vitro, and that somatostatin receptors are expressed in the mammalian inner ear. However, it remains unknown how this protective effect is mediated. In the present study, we show a highly significant protective effect of octreotide (a drug that mimics and is more potent than somatostatin on gentamicin-induced hair cell death, and increased Akt phosphorylation in octreotide-treated organ of Corti explants in vitro. Moreover, we demonstrate that somatostatin receptor-1 knockout mice overexpress somatostatin receptor-2 in the organ of Corti, and are less susceptible to gentamicin-induced hair cell loss than wild-type or somatostatin-1/somatostatin-2 double-knockout mice. Finally, we show that octreotide affects auditory hair cells, enhances spiral ganglion neurite number, and decreases spiral ganglion neurite length.

  8. Preclinical evaluation of [99mTc/EDDA/tricine/HYNIC0, 1-Nal3, Thr8]-octreotide as a new analogue in the detection of somatostatin-receptor-positive tumors.

    Science.gov (United States)

    Gandomkar, Mostafa; Najafi, Reza; Shafiei, Mohammad; Mazidi, Mohammad; Ebrahimi, Sayed Esmaeil Sadat

    2007-08-01

    Radiolabeled somatostatin analogues are important tools for the in vivo localization and targeted radionuclide therapy of somatostatin-receptor-positive tumors. The aim of this study was to evaluate a new somatostatin analogue designed for the labeling with (99m)Tc: [6-hydrazinopyridine-3-carboxylic acid (HYNIC(0)), 1-Nal(3), Thr(8)]-octreotide ([HYNIC]-NATE), using ethylenediamine-N,N'-diacetic acid (EDDA) and tricine as coligands. Synthesis was preformed on a solid phase using a standard Fmoc strategy. Labeling with (99m)Tc was performed at 100 degrees C for 10 min using SnCl(2) as a reductant. Radiochemical analysis involved ITLC and high-performance liquid chromatography methods. Peptide conjugate affinity was determined in AR4-2J cell membranes. The internalization and externalization rates were studied in sstr(2)-expressing AR4-2J cells. Biodistribution of radiopeptide was studied in rats bearing the AR4-2J tumor. Radiolabeling was performed at high specific activities, and radiochemical purity was >95%. Peptide conjugate showed high affinity binding for sstr(2). The radioligand showed a moderate and specific internalization into AR4-2J cells (14.13+/-0.61% at 4 h). In animal biodistribution studies, a receptor-specific uptake of radioactivity was observed in somatostatin-receptor-positive organs. After 4 h, uptake in the AR4-2J tumor was 1.33+/-0.23%ID/g (percentage of injected dose per gram of tissue). These data show that [(99m)Tc/EDDA/tricine/HYNIC]-NATE is a specific radioligand for the somatostatin-receptor-positive tumors and is a suitable candidate for clinical studies.

  9. Preclinical evaluation of [99mTc/EDDA/tricine/HYNIC0, 1-Nal3, Thr8]-octreotide as a new analogue in the detection of somatostatin-receptor-positive tumors

    International Nuclear Information System (INIS)

    Gandomkar, Mostafa; Najafi, Reza; Shafiei, Mohammad; Mazidi, Mohammad; Ebrahimi, Sayed Esmaeil Sadat

    2007-01-01

    Purpose: Radiolabeled somatostatin analogues are important tools for the in vivo localization and targeted radionuclide therapy of somatostatin-receptor-positive tumors. The aim of this study was to evaluate a new somatostatin analogue designed for the labeling with 99m Tc: [6-hydrazinopyridine-3-carboxylic acid (HYNIC 0 ), 1-Nal 3 , Thr 8 ]-octreotide ([HYNIC]-NATE), using ethylenediamine-N,N'-diacetic acid (EDDA) and tricine as coligands. Methods: Synthesis was preformed on a solid phase using a standard Fmoc strategy. Labeling with 99m Tc was performed at 100 o C for 10 min using SnCl 2 as a reductant. Radiochemical analysis involved ITLC and high-performance liquid chromatography methods. Peptide conjugate affinity was determined in AR4-2J cell membranes. The internalization and externalization rates were studied in sstr 2 -expressing AR4-2J cells. Biodistribution of radiopeptide was studied in rats bearing the AR4-2J tumor. Results: Radiolabeling was performed at high specific activities, and radiochemical purity was >95%. Peptide conjugate showed high affinity binding for sstr 2 . The radioligand showed a moderate and specific internalization into AR4-2J cells (14.13±0.61% at 4 h). In animal biodistribution studies, a receptor-specific uptake of radioactivity was observed in somatostatin-receptor-positive organs. After 4 h, uptake in the AR4-2J tumor was 1.33±0.23%ID/g (percentage of injected dose per gram of tissue). Conclusion: These data show that [ 99m Tc/EDDA/tricine/HYNIC]-NATE is a specific radioligand for the somatostatin-receptor-positive tumors and is a suitable candidate for clinical studies

  10. Somatostatin receptor subtype expression in human thyroid tumours.

    Science.gov (United States)

    Klagge, A; Krause, K; Schierle, K; Steinert, F; Dralle, H; Fuhrer, D

    2010-04-01

    Somatostatin receptors (SSTR) are expressed in various endocrine tumours. The expression of SSTR at the tumour cell surface confers the possibility for diagnostic imaging and therapy of tumours using radiolabeled somatostatin analogues. The majority of currently available somatostatin analogues show a higher binding affinity for the SSTR2 subtype. To date, the precise expression pattern of the SSTR subtypes 1-5 in thyroid epithelial tumours remains to be determined. We investigated the mRNA expression of SSTR1-5 in benign and malignant epithelial thyroid tumours [20 cold thyroid nodules (CTNs), 20 toxic thyroid nodules (TTNs), 20 papillary, 20 follicular, and 5 anaplastic carcinomas (PTCs, FTCs, ATCs, respectively)] and compared them to normal surrounding thyroid tissues. Four out of five SSTR subtypes were detected in malignant thyroid tumours, benign neoplasia, and normal surrounding tissue with a predominant expression of SSTR2 and SSTR5, and a weak expression of SSTR1 and SSTR3. Weak SSTR4 mRNA expression was detected in some PTCs. Compared to normal thyroid tissue, SSTR2 was significantly upregulated in PTC and ATC. In addition significant upregulation of SSTR3 was found in PTC. SSTR5 mRNA expression was increased in PTC and FTC and significantly decreased in CTN and TTN compared to normal thyroid tissue. SSTR2 is the predominant subtype in thyroid epithelial tumours with a high expression pattern, in particular, in PTC . Perspectively, the expression of distinct SSTR in thyroid epithelial tumours might represent a promising avenue for diagnostics and therapy of advanced thyroid cancer with somatostatin analogues. Georg Thieme Verlag KG Stuttgart New York.

  11. Evaluation of somatostatin and nucleolin receptors for therapeutic delivery in non-small cell lung cancer stem cells applying the somatostatin-analog DOTATATE and the nucleolin-targeting aptamer AS1411.

    Directory of Open Access Journals (Sweden)

    Sif Holmboe

    Full Text Available Cancer stem cells represent the putative tumor-driving subpopulation thought to account for drug resistance, relapse, and metastatic spread of epithelial and other cancer types. Accordingly, cell surface markers for therapeutic delivery to cancer stem cells are subject of intense research. Somatostatin receptor 2 and nucleolin are known to be overexpressed by various cancer types, which have elicited comprehensive efforts to explore their therapeutic utilization. Here, we evaluated somatostatin receptor 2 targeting and nucleolin targeting for therapeutic delivery to cancer stem cells from lung cancer. Nucleolin is expressed highly but not selectively, while somatostatin receptor 2 is expressed selectively but not highly by cancer cells. The non-small cell lung cancer cell lines A549 and H1299, displayed average levels of both surface molecules as judged based on analysis of a larger cell line panel. H1299 compared to A549 cells showed significantly elevated sphere-forming capacity, indicating higher cancer stem cell content, thus qualifying as suitable test system. Nucleolin-targeting 57Co-DOTA-AS1411 aptamer showed efficient internalization by cancer cells and, remarkably, at even higher efficiency by cancer stem cells. In contrast, somatostatin receptor 2 expression levels were not sufficiently high in H1299 cells to confer efficient uptake by either non-cancer stem cells or cancer stem cells. The data provides indication that the nucleolin-targeting AS1411 aptamer might be used for therapeutic delivery to non-small cell lung cancer stem cells.

  12. Somatostatin receptor 2 knockout/lacZ knockin mice show impaired motor coordination and reveal sites of somatostatin action within the striatum.

    Science.gov (United States)

    Allen, Jeremy P; Hathway, Gareth J; Clarke, Neil J; Jowett, Mike I; Topps, Stephanie; Kendrick, Keith M; Humphrey, Patrick P A; Wilkinson, Lawrence S; Emson, Piers C

    2003-05-01

    The peptide somatostatin can modulate the functional output of the basal ganglia. The exact sites and mechanisms of this action, however, are poorly understood, and the physiological context in which somatostatin acts is unknown. Somatostatin acts as a neuromodulator via a family of five 7-transmembrane G protein-coupled receptors, SSTR1-5, one of which, SSTR2, is known to be functional in the striatum. We have investigated the role of SSTR2 in basal ganglia function using mice in which Sstr2 has been inactivated and replaced by the lacZ reporter gene. Analysis of Sstr2lacZ expression in the brain by beta-galactosidase histochemistry demonstrated a widespread pattern of expression. By comparison to previously published in situ hybridization and immunohistochemical data, Sstr2lacZ expression was shown to accurately recapitulate that of Sstr2 and thus provided a highly sensitive model to investigate cell-type-specific expression of Sstr2. In the striatum, Sstr2 expression was identified in medium spiny projection neurons restricted to the matrix compartment and in cholinergic interneurons. Sstr2 expression was not detected in any other nuclei of the basal ganglia except for a sparse number of nondopaminergic neurons in the substantia nigra. Microdialysis in the striatum showed Sstr2-null mice were selectively refractory to somatostatin-induced dopamine and glutamate release. In behavioural tests, Sstr2-null mice showed normal levels of locomotor activity and normal coordination in undemanding tasks. However, in beam-walking, a test of fine motor control, Sstr2-null mice were severely impaired. Together these data implicate an important neuromodulatory role for SSTR2 in the striatum.

  13. Conversion of daily pegvisomant to weekly pegvisomant combined with long-acting somatostatin analogs, in controlled acromegaly patients

    NARCIS (Netherlands)

    S.J.C.M.M. Neggers (Bas); W.W. de Herder (Wouter); R.A. Feelders (Richard); A-J. van der Lely (Aart-Jan)

    2011-01-01

    textabstractThe efficacy of combined treatment in active acromegaly with both long-acting somatostatin analogs (SRIF) and pegvisomant (PEG-V) has been well established. The aim was to describe the PEG-V dose reductions after the conversion from daily PEG-V to combination treatment. To clarify the

  14. Uptake kinetics of the somatostatin receptor ligand [86Y]DOTA-dPhe1-Tyr3-octreotide ([86Y]SMT487) using positron emission tomography in non-human primates and calculation of radiation doses of the 90Y-labelled analogue

    International Nuclear Information System (INIS)

    Roesch, F.; Brockmann, J.; Koehle, M.

    1999-01-01

    [ 90 Y]DOTA-dPhe 1 -Tyr 3 -octreotide ([ 90 Y]-SMT487) has been suggested as a promising radiotherapeutic agent for somatostatin receptor-expressing tumours. In order to quantify the in vivo parameters of this compound and the radiation doses delivered to healthy organs, the analogue [ 86 Y]DOTA-dPhe 1 -Tyr 3 -octreotide was synthesised and its uptake measured in baboons using positron emission tomography (PET). [ 86 Y]DOTA-dPhe 1 -Tyr 3 -octreotide was administered at two different peptide concentrations, namely 2 and 100 μg peptide per m 2 body surface. The latter concentration corresponded to a radiotherapeutic dose. In a third protocol [ 86 Y]DOTA-dPhe 1 -Tyr 3 -octreotide was injected in conjunction with a simultaneous infusion of an amino acid solution that was high in l-lysine in order to lower the renal uptake of radioyttrium. Quantitative whole-body PET scans were recorded to measure the uptake kinetics for kidneys, liver, lung and bone. The individual absolute uptake kinetics were used to calculate the radiation doses for [ 90 Y]DOTA-dPhe 1 -Tyr 3 -octreotide according to the MIRD recommendations extrapolated to a 70-kg human. The highest radiation dose was received by the kidneys, with 2.1-3.3 mGy per MBq [ 90 Y]DOTA-dPhe 1 -Tyr 3 -octreotide injected. For the 100 μg/m 2 SMT487 protocol with amino acid co-infusion this dose was about 20%-40% lower than for the other two treatment protocols. The liver and the red bone marrow received doses ranging from 0.32 to 0.53 mGy and 0.03 to 0.07 mGy per MBq [ 90 Y]DOTA-dPhe 1 -Tyr 3 -octreotide, respectively. The average effective dose equivalent amounted to 0.23-0.32 mSv/MBq. The comparatively low estimated radiation doses to normal organs support the initiation of clinical phase I trials with [ 90 Y]DOTA-dPhe 1 -Tyr 3 -octreotide in patients with somatostatin receptor-expressing tumours. (orig.)

  15. Union of 99m Tc-HYNIC-TOC at the somatostatin receptors in cells of pancreas cancer

    International Nuclear Information System (INIS)

    Rodriguez C, J.; Ramirez I, M.T.; Ferro F, G.; Pedraza L, M.

    2005-01-01

    The radiation toxic effects have been used in therapy however much 50 years. The absorbed radiation dose can be determined at cellular level using cancerous cell cultures. If the deposited In vitro radiation dose coming from similar activities of several therapeutic radiopharmaceuticals it can compare it will be possible to choose the therapeutic radiopharmaceutical that it offers better dosimetric characteristics for the patient. The objective of this original investigation was to determine the union percentage of the octreotide 99m Tc-HYNlC-TOC to the somatostatin receivers in cells of cancer pancreas as well as the internalization, externalization and cellular viability. It was used the octapeptide, (octreotide, TOC) labelled with 99m Tc by means of the HYNIC chelating agent (6-hydrazine pyridine-3-carboxylic acid) and 3 cellular lines of murine pancreas cancer (AR42J), of cancer of human pancreas (CAPAN) and of one negative cellular line for somatostatin receivers (WRL-68). The 99m Tc-HYNIC-TOC was compared against two negative proofs for somatostatin receivers: the peptide 99m Tc-UBI and the 99m TcO 4 . The cellular lines were conserved in the synthetic media Dulbecco-Eagle. After 2, 4 and 24 h of exhibition to the radiation, the cells are picked up and its are determined the viability by count in a Neubauer camera using tripan blue. In the same times it was calculated the union percentage of the radiopharmaceutical to the cells and the internalization (union to the cytoplasm) and the externalization (union to membrane receivers). With those figures it was calculated the absorbed radiation dose at cellular level. Results: At 4 hours the union percentage of the 99m Tc-HYNlC-TOC to the AR42-J cells was 6.83 times greater than for the WRL-68 control cells of human papilloma, (without receivers of the somatostatin) and for the CAPAN them 4 times greater than for the same cells used as negative control, for the case of the 99m Tc-UBI and the 99m TcO 4 one doesn

  16. Validation of somatostatin receptor scintigraphy in the localization of neuroendocrine tumors

    International Nuclear Information System (INIS)

    Lamberts, S.W.J.; Reubi, J.C.; Krenning, E.P.

    1993-01-01

    Somatostatin analogs are used in the control of hormonal hypersecretion and tumor growth of patients with acromegaly, islet cell carcinomas and carcinoids. Recently we showed that somatostatin receptor positive tumors can be visualized in vivo after the administration of radionuclide-labeled somatostatin analogs. Receptor imaging was positive in 18/21 islet cell tumors, 32/37 carcinoids, 26/28 paragangliomas, 9/14 medullary thyroid carcinomas, and 5/7 small cell lung cancers. Somatostatin receptor imaging is an easy, harmless and painless diagnostic method. It localizes multiple and/or metastatic tumors, predicts the successful control of hormonal hypersecretion by octreotide and seems to be of prognostic value in certain types of cancer. This scintigraphic method might help in patient selection for clinical trials with somatostatin analogs in the treatment of neuroendocrine cancers. (orig.)

  17. Validation of somatostatin receptor scintigraphy in the localization of neuroendocrine tumors

    Energy Technology Data Exchange (ETDEWEB)

    Lamberts, S.W.J. (Depts. of Medicine and Nuclear Medicine, Erasmus Univ., Rotterdam (Netherlands) Div. of Cell Biology and Experimental Cancer Research, Institution of Pathology, Bern Univ. (Switzerland)); Reubi, J.C. (Depts. of Medicine and Nuclear Medicine, Erasmus Univ., Rotterdam (Netherlands) Div. of Cell Biology and Experimental Cancer Research, Institution of Pathology, Bern Univ. (Switzerland)); Krenning, E.P. (Depts. of Medicine and Nuclear Medicine, Erasmus Univ., Rotterdam (Netherlands) Div. of Cell Biology and Experimental Cancer Research, Institution of Pathology, Bern Univ. (Switzerland))

    1993-01-01

    Somatostatin analogs are used in the control of hormonal hypersecretion and tumor growth of patients with acromegaly, islet cell carcinomas and carcinoids. Recently we showed that somatostatin receptor positive tumors can be visualized in vivo after the administration of radionuclide-labeled somatostatin analogs. Receptor imaging was positive in 18/21 islet cell tumors, 32/37 carcinoids, 26/28 paragangliomas, 9/14 medullary thyroid carcinomas, and 5/7 small cell lung cancers. Somatostatin receptor imaging is an easy, harmless and painless diagnostic method. It localizes multiple and/or metastatic tumors, predicts the successful control of hormonal hypersecretion by octreotide and seems to be of prognostic value in certain types of cancer. This scintigraphic method might help in patient selection for clinical trials with somatostatin analogs in the treatment of neuroendocrine cancers. (orig.).

  18. Deficiencies in fat-soluble vitamins in long-term users of somatostatin analogue

    NARCIS (Netherlands)

    Fiebrich, H. -B.; van den Berg, G.; Kema, I. P.; Links, T. P.; Kleibeuker, J. H.; van Beek, A. P.; Walenkamp, A. M. E.; Sluiter, W. J.; de Vries, E. G. E.

    2010-01-01

    P>Background Somatostatin analogues are administered to control hormone hypersecretion in acromegaly and carcinoid patients. Somatostatin analogues can increase fat in the stools, which can lead to loss of fat-soluble vitamins. The effect of long-term somatostatin analogue use on vitamin levels

  19. Reduced Numbers of Somatostatin Receptors in the Cerebral Cortex in Alzheimer's Disease

    Science.gov (United States)

    Flint Beal, M.; Mazurek, Michael F.; Tran, Vinh T.; Chattha, Geetinder; Bird, Edward D.; Martin, Joseph B.

    1985-07-01

    Somatostatin receptor concentrations were measured in patients with Alzheimer's disease and controls. In the frontal cortex (Brodmann areas 6, 9, and 10) and temporal cortex (Brodmann area 21), the concentrations of somatostatin in receptors in the patients were reduced to approximately 50 percent of control values. A 40 percent reduction was seen in the hippocampus, while no significant changes were found in the cingulate cortex, postcentral gyrus, temporal pole, and superior temporal gyrus. Scatchard analysis showed a reduction in receptor number rather than a change in affinity. Somatostatin-like immunoreactivity was significantly reduced in both the frontal and temporal cortex. Somatostatin-like immunoreactivity was linearly related to somatostatin-receptor binding in the cortices of Alzheimer's patients. These findings may reflect degeneration of postsynaptic neurons or cortical afferents in the patients' cerebral cortices. Alternatively, decreased somatostatinlike immunoreactivity in Alzheimer's disease might indicate increased release of somatostatin and down regulation of postsynaptic receptors.

  20. High-Dose Lanreotide in the Treatment of Poorly Differentiated Pancreatic Neuroendocrine Carcinoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Frank Van Fraeyenhove

    2014-03-01

    Full Text Available Pancreatic neuroendocrine tumors (NETs, including poorly differentiated carcinomas (NECs, are rarely encountered. The majority of these tumors do not secrete excess hormones, but functioning NETs produce large amounts of vasoactive peptides and may cause carcinoid syndrome. Synthetic somatostatin analogs (SSAs have been widely used in NETs for control of hormonal syndromes. Here, we present a case of poorly differentiated, grade 3 pancreatic NEC associated with carcinoid syndrome, for which adequate symptom control was achieved for 2 years and 4 months using the long-acting SSA lanreotide Autogel®. In February 2009, a 55-year-old woman presented with episodes of flushing, diarrhea and epigastric pain. Imaging techniques revealed the presence of a metabolically active mass expressing somatostatin receptors in the hilar area of the liver. Histopathological examination confirmed the malignant nature of the mass, which was identified as a poorly differentiated grade 3 pancreatic NEC (TNM staging: T4NxM0. Therapeutic options were limited for the patient because of the extent of the primary mass involving the celiac axis, severe gastrointestinal toxicity experienced as a side effect of chemotherapy with cisplatin-etoposide and, later in the course of the disease, extensive liver metastases and carcinoid heart syndrome. Along with a palliative debulking surgery and right portal vein embolization, biotherapy with a high dose of lanreotide Autogel (120 mg/14 days contributed to alleviation of symptoms caused by hormone overproduction, even after the development of liver metastases. These results suggest that patients with poorly differentiated NECs who exhibit signs of carcinoid syndrome can benefit from treatment with somatostatin analogs.

  1. Somatostatin receptor scintigraphy in patients with cat-scratch disease

    International Nuclear Information System (INIS)

    Krause, R.; Schnedl, W.J.; Hoier, S.; Piswanger-Soelkner, C.; Lipp, R.W.; Daxboeck, F.; Reisinger, E.C.

    2006-01-01

    Aim: somatostatin receptor scintigraphy images various neoplastic, granulomatous, and auto-immun diseases. Cat-scratch disease in an infectious granulomatous disease usually affecting the lymphnodes. It is not known whether cat-scratch disease provides positive somatostatin receptor scintigrams. Patients, methods: twelve patients with lymphadenitis and suspected cat-scratch disease were investigated by immunofluorescence antibody testing and somatostatin receptor scintigraphy. Suppurated lymphnodes were extracted or drained and Bartonella henselae specific PCR was then performed. Results: eleven of 12 patients showed IgG antibodies against B. henselea. SRS showed positive scintigraphic results in 6 of 11 patients with CSD. B. henselae DNA was detected in tissue of lymphnodes from 4 of 5 patients with lymphnode extraction or lymphnode drainage. SRS demonstrated positive scintigrams in all patients with a positive PCR. In one patient with suspected CSD SRS was negative as well as antibody testing. Conclusion: somatostatin receptor scintigraphy correlated with positive Bartonella henselae specific PCR tests and positive Bartonella henselae specific antibody tests in patients with CSD. (orig.)

  2. Somatostatin receptor scintigraphy in patients with cat-scratch disease

    Energy Technology Data Exchange (ETDEWEB)

    Krause, R.; Schnedl, W.J.; Hoier, S. [Div. of Infectious Diseases, Dept. of Internal Medicine, Univ. Graz (Austria); Piswanger-Soelkner, C.; Lipp, R.W. [Div. of Nuclear Medicine, Dept. of Internal Medicine, Univ. Graz (Austria); Daxboeck, F. [Clinical Inst. for Hygiene and Medical Microbiology, Div. of Hospital Hygiene, Univ. of Vienna (Austria); Reisinger, E.C. [Div. of Infectious Diseases and Tropical Medicine, Dept. of Internal Medicine, Univ. Rostock (Germany)

    2006-07-01

    Aim: somatostatin receptor scintigraphy images various neoplastic, granulomatous, and auto-immun diseases. Cat-scratch disease in an infectious granulomatous disease usually affecting the lymphnodes. It is not known whether cat-scratch disease provides positive somatostatin receptor scintigrams. Patients, methods: twelve patients with lymphadenitis and suspected cat-scratch disease were investigated by immunofluorescence antibody testing and somatostatin receptor scintigraphy. Suppurated lymphnodes were extracted or drained and Bartonella henselae specific PCR was then performed. Results: eleven of 12 patients showed IgG antibodies against B. henselea. SRS showed positive scintigraphic results in 6 of 11 patients with CSD. B. henselae DNA was detected in tissue of lymphnodes from 4 of 5 patients with lymphnode extraction or lymphnode drainage. SRS demonstrated positive scintigrams in all patients with a positive PCR. In one patient with suspected CSD SRS was negative as well as antibody testing. Conclusion: somatostatin receptor scintigraphy correlated with positive Bartonella henselae specific PCR tests and positive Bartonella henselae specific antibody tests in patients with CSD. (orig.)

  3. Receptor binding of somatostatin-14 and somatostatin-28 in rat brain: differential modulation by nucleotides and ions.

    Science.gov (United States)

    Srikant, C B; Dahan, A; Craig, C

    1990-02-04

    The tissue-selective binding of the two principal bioactive forms of somatostatin, somatostatin-14 (SS-14) and somatostatin-28 (SS-28), their ability to modulate cAMP-dependent and -independent regulation of post-receptor events to different degrees and the documentation of specific labelling of SS receptor subtypes with SS-28 but not SS-14 in discrete regions of rat brain suggest the existence of distinct SS-14 and SS-28 binding sites. Receptor binding of SS-14 ligands has been shown to be modulated by nucleotides and ions, but the effect of these agents on SS-28 binding has not been studied. In the present study we investigated the effects of adenine and guanine nucleotides as well as monovalent and divalent cations on rat brain SS receptors quantitated with radioiodinated analogs of SS-14 ([125I-Tyr11]SS14, referred to in this paper as SS-14) and SS-28 ([Leu8, D-Trp22, 125I-Tyr25] SS-28, referred to as LTT* SS-28) in order to determine if distinct receptor sites for SS-14 and SS-28 could be distinguished on the basis of their modulation by nucleotides and ions. GTP as well as ATP exerted a dose-dependent inhibition (over a concentration range of 10(-7)-10(-3) M) of the binding of the two radioligands. The nucleotide inhibition of binding resulted in a decrease the Bmax of the SS receptors, the binding affinity remaining unaltered. GTP (10(-4) M) decreased the Bmax of LTT* SS-28 binding sites to a greater extent than ATP (145 +/- 10 and 228 +/- 16 respectively, compared to control value of 320 +/- 20 pmol mg-1). Under identical conditions GTP was less effective than ATP in reducing the number of T* SS-14 binding sites (Bmax = 227 +/- 8 and 182 +/- 15, respectively, compared to 340 +/- 15 pmol mg-1 in the absence of nucleotides). Monovalent cations inhibited the binding of both radioligands, Li+ and Na+ inhibited the binding of T* SS-14 to a greater extent than K+. The effect of divalent cations on the other hand was varied. At low concentration (2 mM) Mg2+, Ba2

  4. Coupling of guanine nucleotide inhibitory protein to somatostatin receptors on pancreatic acinar membranes

    International Nuclear Information System (INIS)

    Sakamoto, C.; Matozaki, T.; Nagao, M.; Baba, S.

    1987-01-01

    Guanine nucleotides and pertussis toxin were used to investigate whether somatostatin receptors interact with the guanine nucleotide inhibitory protein (NI) on pancreatic acinar membranes in the rat. Guanine nucleotides reduced 125 I-[Tyr 1 ]somatostatin binding to acinar membranes up to 80%, with rank order of potency being 5'-guanylyl imidodiphosphate [Gpp(NH)p]>GTP>TDP>GMP. Scatchard analysis revealed that the decrease in somatostatin binding caused by Gpp(NH)p was due to the decrease in the maximum binding capacity without a significant change in the binding affinity. The inhibitory effect of Gpp(NH)p was partially abolished in the absence of Mg 2+ . When pancreatic acini were treated with 1 μg/ml pertussis toxin for 4 h, subsequent 125 I-[Tyr 1 ]somatostatin binding to acinar membranes was reduced. Pertussis toxin treatment also abolished the inhibitory effect of somatostatin on vasoactive intestinal peptide-stimulated increase in cellular content of adenosine 3',5'-cyclic monophosphate (cAMP) in the acini. The present results suggest that 1) somatostatin probably functions in the pancreas to regulate adenylate cyclase enzyme system via Ni, 2) the extent of modification of Ni is correlated with the ability of somatostatin to inhibit cAMP accumulation in acini, and 3) guanine nucleotides also inhibit somatostatin binding to its receptor

  5. Kidney protection during peptide receptor radionuclide therapy with somatostatin analogues.

    NARCIS (Netherlands)

    Rolleman, E.J.; Melis, M.; Valkema, R.; Boerman, O.C.; Krenning, E.P.; Jong, M. de

    2010-01-01

    This review focuses on the present status of kidney protection during peptide receptor radionuclide therapy (PRRT) using radiolabelled somatostatin analogues. This treatment modality for somatostatin receptor-positive tumours is limited by renal reabsorption and retention of radiolabelled peptides

  6. Somatostatin receptor-mediated imaging and therapy: basic science, current knowledge, limitations and future perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Breeman, W.A.P.; Jong, M. de; Kwekkeboom, D.J.; Valkema, R.; Bakker, W.H.; Kooij, P.P.M. [Dept. of Nuclear Medicine, Erasmus Medical Centre Rotterdam (Netherlands); Visser, T.J. [Dept. of Internal Medicine, Erasmus Medical Centre Rotterdam (Netherlands); Krenning, E.P. [Dept. of Nuclear Medicine, Erasmus Medical Centre Rotterdam (Netherlands); Dept. of Internal Medicine, Erasmus Medical Centre Rotterdam (Netherlands)

    2001-09-01

    In vivo somatostatin receptor-mediated scintigraphy has proven to be a valuable method for the visualisation of neuroendocrine tumours and their metastases. A new application is the use of radiolabelled analogues for somatostatin receptor-mediated therapy. This paper presents a review on the basic science, historical background and current knowledge of somatostatin receptor subtypes and their expression in neuroendocrine tumours. New somatostatin analogues, new chelators, ''new'' radionuclides and combinations thereof are also discussed. Due attention is given to limitations and future perspectives of somatostatin receptor-mediated imaging and therapy. (orig.)

  7. Somatostatin receptor-mediated imaging and therapy: basic science, current knowledge, limitations and future perspectives

    International Nuclear Information System (INIS)

    Breeman, W.A.P.; Jong, M. de; Kwekkeboom, D.J.; Valkema, R.; Bakker, W.H.; Kooij, P.P.M.; Visser, T.J.; Krenning, E.P.

    2001-01-01

    In vivo somatostatin receptor-mediated scintigraphy has proven to be a valuable method for the visualisation of neuroendocrine tumours and their metastases. A new application is the use of radiolabelled analogues for somatostatin receptor-mediated therapy. This paper presents a review on the basic science, historical background and current knowledge of somatostatin receptor subtypes and their expression in neuroendocrine tumours. New somatostatin analogues, new chelators, ''new'' radionuclides and combinations thereof are also discussed. Due attention is given to limitations and future perspectives of somatostatin receptor-mediated imaging and therapy. (orig.)

  8. In vivo somatostatin, vasopressin, and oxytocin synthesis in diabetic rat hypothalamus

    International Nuclear Information System (INIS)

    Fernstrom, J.D.; Fernstrom, M.H.; Kwok, R.P.

    1990-01-01

    The in vivo labeling of somatostatin-14, somatostatin-28, arginine vasopressin, and oxytocin was studied in rat hypothalamus after third ventricular administration of [35S]cysteine to streptozotocin-diabetic and normal rats. Immunoreactive somatostatin levels in hypothalamus were unaffected by diabetes, as was the incorporation of [35S]cysteine into hypothalamic somatostatin-14 and somatostatin-28. In contrast, immunoreactive vasopressin levels in hypothalamus and posterior pituitary (and oxytocin levels in posterior pituitary) were below normal in diabetic rats. Moreover, [35S]cysteine incorporation into hypothalamic vasopressin and oxytocin (probably mainly in the paraventricular nucleus because of its proximity to the third ventricular site of label injection) was significantly above normal. The increments in vasopressin and oxytocin labeling were reversed by insulin administration. In vivo cysteine specific activity and the labeling of acid-precipitable protein did not differ between normal and diabetic animals; effects of diabetes on vasopressin and oxytocin labeling were therefore not caused by simple differences in cysteine specific activity. These results suggest that diabetes (1) does not influence the production of somatostatin peptides in hypothalamus but (2) stimulates the synthesis of vasopressin and oxytocin. For vasopressin at least, the increase in synthesis may be a compensatory response to the known increase in its secretion that occurs in uncontrolled diabetes

  9. Diagnostic value of somatostatin receptor scintigraphy in patients with intracranial tumours

    International Nuclear Information System (INIS)

    Luyken, C.; Hildebrandt, G.; Scheidhauer, K.; Kirsch, B.

    1993-01-01

    The aim of the study was to detect the SR binding sites in intracranial tumours and to evaluate the benefit of SRS in pre- and postoperative diagnostics. 86 patients with 94 intracranial tumours (39 meningiomas, 18 pituitary adenomas, 11 gliomas grade 3 or 4, 8 gliomas grade 2, 5 neurinomas, 5 intracranial metastases, 4 tumours of the orbit, 2 neurofibromas, 1 brain abscess and 1 cystic lesion) were examined. 111 In-octreotide was injected i.v. as 10 μg or 20 μg bolus, corresponding to 110 or 220 MBq (3 or 6 mCi). Gamma-camera images and SPECT were obtained 3-6 h and 24 h post injection. The scintigraphic evaluation was performed without knowledge of CT and MRI results. The histological classification corresponded to the WHO grading system. Somatostatin binding sites were detected in vito using somatostatin-gold conjugates. All patients with meningiomas showed a high focal tracer uptake corresponding to SR binding sites in vitro, whereas only in 50% of the pituitary adenomas SRS was positive. Neurinomas did not show any tracer uptake. In patients with gliomas with disturbed blood-brain-barrier positive tracer uptake was detected, while none of the gliomas with intact blood-brain-barrier could be visualized by SRS but showed somatostatin binding sites in vitro. In intracranial metastases a local tracer uptake was detected in vivo. In vitro 3 of 4 cases showed somatostatin binding sites. In 2 cases extracranial tracer uptake showed the primary tumour and metastases of the lymphnodes. Somatostatin receptor scintigraphy can help to detect or to exclude meningiomas especially in the cerebellopontine angle or in the orbit. In intracranial metastases SRS may point to the primary tumour or other metastases. In all other intracranial tumours receptor scintigraphy provides no clinical relevant information. (orig./MG) [de

  10. Somatostatin Receptor Scintigraphy (SRS) with 99m-Tc HYNIC-TOC

    International Nuclear Information System (INIS)

    Zarlenga, A.C.; Parma, P.; Arashiro, J.; Castiglia, S.; Obenaus, E.

    2002-01-01

    Background: This compound is a synthetic analogue of somatostatin by conjugating the Hydrazinocotinamide (Hynic) to Tyr 3 -Octreotide (Toc) radiolabeling via quelation with 99m Tc. Purpose: We have analyzed the feasibility in detecting neuroendocrine tumors (NET) by somatostatin receptor with 99m Tc Hynic-Toc. Methods: After comparative studies between 99m Tc Hynic-Toc and 111 In (pentetreotide) with excellent correlation, we have performed 48 scintigrams with 99m Tc Hynic-Toc. 35 patients with suspicions of NET were included (19 women, 16 men. Age range 22-75 y). We have performed planar images at 1,2,24 hs and tomographic images at 150 min after intravenous injection of 740 MBq 99m Tc Hynic-Toc. We compare the results with other diagnosis modalities and /or the histopathological findings after biopsy or surgery. Results: True Positive:17; True Negative:11; False Positive: 4; False Negative:3. Specificity=73.3%; Sensitivity=85%; Accuracy=80%; Not adverse effects were observed. Conclusions: 99m Tc Hynic-Toc is not limited availability of the isotope. It is a suitable radiopharmaceutical for in vivo evaluation to define tumor receptor status, staging, and for identification of patients who may benefit from therapy with somatostatin. The tumor uptake at 24 hs allows a better visualization of abdominal tumor sites. Tc Hynic-Toc is an alternative to 111 In-pentetreotide for imaging somatostatin receptor positive tumors. The study was offered to patients whom the scintigraphy with 111 In-pentetreotide offers a diagnosis alternative with high specificity and accessible cost

  11. Therapy with radiolabelled somatostatin analogs in neuroendocrine tumors

    International Nuclear Information System (INIS)

    Kunikowska, J.; Krolicki, L.

    2007-01-01

    In the 80's the discovery of somatostatin receptors expression on NET cells enabled the application of somatostatin analogues in diagnosis and therapy. Initially, 'cold' somatostatin analogs were used for therapeutical purpose, with overall good clinical response, but with minimal anti-proliferation effect. Furthermore, radiolabelled receptor-binding peptides have been shown to be an important class of radiopharmaceuticals for tumor diagnosis and therapy with minimal side-effects. Specific binding between receptor on tumor cell and peptide with beta emitting radionuclide act not only on tumor related symptoms but also on tumor cell via radiotoxic effect of beta radiation. Discoveries of next receptor combinations, allow the work over synthesis and applications of next receptors' analogs both in diagnosis and in therapy. Due to complex characteristics of NET's, the use therapeutic 'cocktail' containing the variety analogs may be of great importance. (author)

  12. Technetium-99m labeled somatostatin and analogs: synthesis, characterization and in vivo evaluation

    International Nuclear Information System (INIS)

    Amartey, J.K.

    1993-01-01

    Technetium-99m complexes of somatostatin and analogs were synthesized following the introduction of sulfhydryl groups with 2-iminothiolane (Traut's Reagent). In rats the complex was taken up by the liver, kidneys, adrenals, lungs and the pancreas. Analysis of urine samples of treated rats showed that the radiochemicals have reasonably good in vivo stability. This implies that the complexes may be potentially useful for biochemical characterization of somatostatin receptors and also in scintigraphic detection of somatostatin receptor positive tumors, especially for metastatic deposits in patients on somatostatin therapy. (Author)

  13. Somatostatin receptors in rat hippocampus: localization to intrinsic neurons

    International Nuclear Information System (INIS)

    Palacios, J.M.; Reubi, J.C.; Maurer, R.

    1986-01-01

    The effect of neurotoxic chemical and electrolytical lesions on somatostatin (SS) receptor binding in the septo-hippocampal afferents, pyramidal and granule cells of the rat hippocampus was examined by autoradiography using the stable SS analogue 125 I-204-090 as radioligand. Electrolytical lesions of the septum did not result in modification of SS binding in the hippocampus. In contrast, both granule cell lesion with colchicine and pyramidal or pyramidal and granule cell lesions with increasing kainic acid doses did result in a specific decrease of binding in the dentate gyrus and hippocampus (CA 1 and CA 3 ). These results suggest that SS receptors in the hippocampus are probably associated with elements from intrinsic neurons. (Author)

  14. Synthesis, radiochemistry and biological evaluation of a new somatostatin analogue (SDZ 219-387) labelled with technetium-99m

    International Nuclear Information System (INIS)

    Maina, T.; Stolz, B.; Albert, R.; Bruns, C.; Koch, P.; Maecke, H.

    1994-01-01

    A new derivative of octreotide SDZ 219-387 [PnAO-(D)Phe 1 -octreotide] was synthesized, which binds specifically and with high affinity to somatostatin receptors in vitro (pK i =9.79±0.16). This new somatostatin analogue chelates technetium-99m under mild labelling conditions in good yields. The resulting [ 99m Tc]SDZ 219-387 was stable up to 6 h after labelling and could be isolated in a pure radiochemical and chemical form by high-perfomance liquid chromatographic purification. The intravenous administration of purified [ 99m Tc]SDZ 219-387 revealed that the radioligand was rapidly cleared from circulation, and tumour uptake of 0.38% ID/g was observed at 1.5 h post injection. [ 99m Tc]SDZ 219-387 specifically interacted with somatostatin binding sites on the tumour. However, the radioligand is highly lipophilic and excreted mainly through the hepatobiliary system. As a consequence, [ 99m Tc]SDZ 219-387 exhibits increased background activity and therefore is not appropriate for the in vivo visualization of somatostatin receptor-positive tumours and/or their metastases in the abdomen. (orig.)

  15. Activation of Brain Somatostatin Signaling Suppresses CRF Receptor-Mediated Stress Response.

    Science.gov (United States)

    Stengel, Andreas; Taché, Yvette F

    2017-01-01

    Corticotropin-releasing factor (CRF) is the hallmark brain peptide triggering the response to stress and mediates-in addition to the stimulation of the hypothalamus-pituitary-adrenal (HPA) axis-other hormonal, behavioral, autonomic and visceral components. Earlier reports indicate that somatostatin-28 injected intracerebroventricularly counteracts the acute stress-induced ACTH and catecholamine release. Mounting evidence now supports that activation of brain somatostatin signaling exerts a broader anti-stress effect by blunting the endocrine, autonomic, behavioral (with a focus on food intake) and visceral gastrointestinal motor responses through the involvement of distinct somatostatin receptor subtypes.

  16. Basal Forebrain Gating by Somatostatin Neurons Drives Prefrontal Cortical Activity.

    Science.gov (United States)

    Espinosa, Nelson; Alonso, Alejandra; Morales, Cristian; Espinosa, Pedro; Chávez, Andrés E; Fuentealba, Pablo

    2017-11-17

    The basal forebrain provides modulatory input to the cortex regulating brain states and cognitive processing. Somatostatin-expressing neurons constitute a heterogeneous GABAergic population known to functionally inhibit basal forebrain cortically projecting cells thus favoring sleep and cortical synchronization. However, it remains unclear if somatostatin cells can regulate population activity patterns in the basal forebrain and modulate cortical dynamics. Here, we demonstrate that somatostatin neurons regulate the corticopetal synaptic output of the basal forebrain impinging on cortical activity and behavior. Optogenetic inactivation of somatostatin neurons in vivo rapidly modified neural activity in the basal forebrain, with the consequent enhancement and desynchronization of activity in the prefrontal cortex, reflected in both neuronal spiking and network oscillations. Cortical activation was partially dependent on cholinergic transmission, suppressing slow waves and potentiating gamma oscillations. In addition, recruitment dynamics was cell type-specific, with interneurons showing similar temporal profiles, but stronger responses than pyramidal cells. Finally, optogenetic stimulation of quiescent animals during resting periods prompted locomotor activity, suggesting generalized cortical activation and increased arousal. Altogether, we provide physiological and behavioral evidence indicating that somatostatin neurons are pivotal in gating the synaptic output of the basal forebrain, thus indirectly controlling cortical operations via both cholinergic and non-cholinergic mechanisms. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  17. Somatostatin-like peptide and regeneration capacities in planarians.

    Science.gov (United States)

    Bautz, A; Schilt, J

    1986-11-01

    The presence of a neuropeptide immunologically related to somatostatin (SRIF) has been investigated in the neurosecretory cells of two regenerating planarian species (Dugesia lugubris and Dendrocoelum lacteum). A correlation has been shown between the discharge of the SRIF-like-immunoreactive cells during the first hours after amputation and the capacity to regenerate, and between the persistence of numerous positive cells and the lack of regeneration. These results suggest that somatostatin might play a regulatory (inhibitory) role on the cellular proliferation which leads to the blastema edification.

  18. Activation of Brain Somatostatin Signaling Suppresses CRF Receptor-Mediated Stress Response

    Directory of Open Access Journals (Sweden)

    Andreas Stengel

    2017-04-01

    Full Text Available Corticotropin-releasing factor (CRF is the hallmark brain peptide triggering the response to stress and mediates—in addition to the stimulation of the hypothalamus-pituitary-adrenal (HPA axis—other hormonal, behavioral, autonomic and visceral components. Earlier reports indicate that somatostatin-28 injected intracerebroventricularly counteracts the acute stress-induced ACTH and catecholamine release. Mounting evidence now supports that activation of brain somatostatin signaling exerts a broader anti-stress effect by blunting the endocrine, autonomic, behavioral (with a focus on food intake and visceral gastrointestinal motor responses through the involvement of distinct somatostatin receptor subtypes.

  19. Expression of somatostatin receptors subtype 2 and 5 in extraocular muscle tissue of hypothyroidism animal induced by 131I

    International Nuclear Information System (INIS)

    Li Fangdu; Chu Qiaomei; Xu Peikang; Yao Xiaohong; Shen Jiangfan

    2012-01-01

    Objective: To observe the expression and distribution of somatostatin receptors 2 and 5 (SSTR2, 5) in extraocular muscle in hypothyroidism and thyroid associated ophthalmopathy (TAO) Wister rats induced by 131 I. Methods: 20 Wister rats were randomly divided into experimental group and normal group(group D). According to 131 I doses of intraperitoneal injection, the experimental groups were divided into low (group A), middle (group B) and high dose group (group C). After 8 weeks, all rats were sacrificed and orbital tissue sections were applied to HE staining and Immunohistochemistry for the analysis of rat orbital tissue changes and SSTR2 and 5 distribution in extraocular muscle. Results: The serum FT 4 levels in group A (16.98±2.92 pmol / L), group B (1.84±0.44 pmol / L) and group C (1.35 ±0.37 pmol /L) eight weeks after 131 I injection were decreased, and had significant difference compared with group D (P 4 levels in group B and C were significantly lower than that in group A (P 0.05). Orbital tissue in experimental group showed mucoid degeneration and edema, the extent was about 25% in group A, 50% in group B, 70% in group C. The rats in group B and group C appeared obvious proliferation of fibrous and adipose tissue, muscle fibers degeneration fracture, even extraocular muscles in group C have vacuole formation. Immunohistochemical analysis displayed highest SSTR5 distribution and strongest expression was in extraocular muscle of group C, second in A B combination group (A and B groups)and weakest in group D. There were significant differences between A B combination group,group C and group D (P 0.05). Conclusion: This study observed the distribution and expression of SSTR2 and SSTR5 in extraocular muscle on the established hypothyroidism animal model. It is some significance for understanding the mechanism of somatostatin receptors in occurrence and development of TAO, similar to provide a reference for the use of somatostatin analogue orbital imaging

  20. In vitro effect of Δ9-tetrahydrocannabinol to stimulate somatostatin release and block that of luteinizing hormone-releasing hormone by suppression of the release of prostaglandin E2

    International Nuclear Information System (INIS)

    Rettori, V.; Aguila, M.C.; McCann, S.M.; Gimeno, M.F.; Franchi, A.M.

    1990-01-01

    Previous in vivo studies have shown that Δ 9 -tetrahydrocannabinol (THC), the principal active ingredient in marijuana, can suppress both luteinizing hormone (LH) and growth hormone (GH) secretion after its injection into the third ventricle of conscious male rats. The present studies were deigned to determine the mechanism of these effects. Various doses of THC were incubated with either stalk median eminence fragments (MEs) or mediobasal hypothalamic (MBH) fragments in vitro. Although THC (10 nM) did not alter basal release of LH-releasing hormone (LHRH) from MEs in vitro, it completely blocked the stimulatory action of dopamine or nonrepinephrine on LHRH release. The effective doses to block LHRH release were associated with a blockade of synthesis and release of prostaglandin E 2 (PGE 2 ) from MBH in vitro. In contrast to the suppressive effect of THC on LHRH release, somatostatin release from MEs was enhanced in a dose-related manner with a minimal effective dose of 1 nM. Since PGE 2 suppresses somatostatin release, this enhancement may also be related to the suppressive effect of THC on PGE 2 synthesis and release. The authors speculate that these actions are mediated by the recently discovered THC receptors in the tissue. The results indicate that the suppressive effect of THC on LH release is mediated by a blockade of LHRH release, whereas the suppressive effect of the compound on growth hormone release is mediated, at least in part, by a stimulation of somatostatin release

  1. DOTA-NOC, a high-affinity ligand of somatostatin receptor subtypes 2, 3 and 5 for labelling with various radiometals

    International Nuclear Information System (INIS)

    Wild, Damian; Schmitt, Joerg S.; Ginj, Mihaela; Maecke, Helmut R.; Bernard, Bert F.; Krenning, Eric; Jong, Marion de; Wenger, Sandra; Reubi, Jean-Claude

    2003-01-01

    Earlier studies have shown that modification of the octapeptide octreotide in positions 3 and 8 may result in compounds with increased somatostatin receptor affinity that, if radiolabelled, display improved uptake in somatostatin receptor-positive tumours. The aim of a recent research study in our laboratory was to employ the parallel peptide synthesis approach by further exchanging the amino acid in position 3 of octreotide and coupling the macrocyclic chelator DOTA(1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) to these peptides for labelling with radiometals like gallium-67 or -68, indium-111, yttrium-90 and lutetium-177. The purpose was to find radiopeptides with an improved somatostatin receptor binding profile in order to extend the spectrum of targeted tumours. A first peptide, [ 111 In, 90 Y-DOTA]-1-Nal 3 -octreotide ( 111 In, 90 Y-DOTA-NOC), was isolated which showed an improved profile. In III -DOTA-NOC exhibited the following IC 50 values (nM) when studied in competition with [ 125 I][Leu 8 , d-Trp 22 , Tyr 25 ]somatostatin-28 (values for Y III -DOTA-NOC are shown in parentheses): sstr2, 2.9±0.1 (3.3±0.2); sstr3, 8±2 (26±1.9); sstr5, 11.2±3.5 (10.4±1.6). Affinity towards sstr1 and 4 was very low or absent. In III -DOTA-NOC is superior to all somatostatin-based radiopeptides having this particular type of binding profile, including DOTA-lanreotide, and has three to four times higher binding affinity to sstr2 than In III ,Y III -DOTA-Tyr 3 -octreotide (In III ,Y III -DOTA-TOC). In addition, [ 111 In]DOTA-NOC showed a specific and high rate of internalization into AR4-2J rat pancreatic tumour cells which, after 4 h, was about two times higher than that of [ 111 In]DOTA-TOC and three times higher than that of [ 111 In]DOTA-octreotide ([ 111 In]DOTA-OC). The internalized radiopeptides were externalized intact upon 2 h of internalization followed by an acid wash. After 2-3 h of externalization a plateau is reached, indicating a steady

  2. Iodine-131 labelled octreotide: not an option for somatostatin receptor therapy

    International Nuclear Information System (INIS)

    Bakker, W.H.; Breeman, W.A.P.; Pluijm, M.E. van der; Jong, M. de; Visser, T.J.; Krenning, E.P.

    1996-01-01

    This study deals with the radioiodination of very small amounts of peptide on a therapeutic scale, the required purification procedures after radioiodination, and the influence of high beta fluxes from 131 I on a peptide during radioiodination and purification. Based on the regularly used therapeutic doses of 131 I in cancer treatment and out previous experience with [ 111 In-DTPA-D-Phe 1 ]-octreotide, it was assumed that a minimal effective therapeutic dose of 3.7 GBq 131 I has to be coupled to a maximum of ∼100 μg peptide, representing only a slight excess of peptide over 131 I. This contrasts with non-peptide radiopharmaceuticals in which high compound to radionuclide ratios are usually used. Labelling at low peptide to radionuclide ratios (low labelling yields) results in the formation of di-iodinated compounds, whereas at high peptide to radionuclide ratios mono-iodinated products of low specific activity are formed. Thus, after radioiodination the desired mono-iodinated peptide has to be separated form unreacted iodide, and from di-iodinated and unreacted peptide, as both compounds compete for the receptors. Possible radiolysis of the peptide during labelling and separation steps were investigated by irradiating 30 μg unlabelled peptide with 370 MBq 131 I in a small volume. The peptide composition of the incubation mixtures was investigated by high-performance liquid chromatography after irradiation for 30 min to 24 h. The results showed that the peptide was degraded with a half-life of less than 1 h. During the preparation of a real therapeutic dose (at much higher β-flux) the peptide will be degraded even faster during the various steps required. In conclusion, intact mono-iodinated 131 I-labelled somatostatin analogues for peptide receptor therapy will be difficult to obtain. (orig./VHE)

  3. Effect of somatostatin on glucose homeostasis in conscious long-fasted dogs

    International Nuclear Information System (INIS)

    Stevenson, R.W.; Steiner, K.E.; Hendrick, G.K.; Cherrington, A.D.

    1987-01-01

    The effects of somatostatin plus intraportal insulin and glucagon replacement (pancreatic clamp) on carbohydrate metabolism were studied in conscious dogs fasted for 7 days so that gluconeogenesis was a major contributor to total glucose production. By use of [3- 3 H]glucose, glucose production (R a ) and utilization (R d ) and glucose clearance were assessed before and after implementation of the pancreatic clamp. After an initial control period, somatostatin (0.8 μg·kg -1 ·min -1 ) was infused with intraportal replacement amounts of glucagon and insulin. The insulin infusion rate was varied to maintain euglycemia and then kept constant for 250 min. Plasma glucagon was similar before and during somatostatin infusion, while plasma insulin was lower. Plasma glucose levels remained similar while R a and R d and the ratio of glucose clearance to plasma insulin were significantly increased. Net hepatic lactate uptake and [ 14 C]alanine plus [ 14 C]lactate conversion to [ 14 C]glucose increased. In conclusion, somatostatin alters glucose clearance in 7-day fasted dogs, resulting in changes in several indices of carbohydrate metabolism

  4. Somatostatin receptor scintigraphy using (99m)Tc-EDDA/HYNIC-TOC in patients with medullary thyroid carcinoma

    NARCIS (Netherlands)

    Czepczynski, Rafal; Parisella, Maria Gemma; Kosowicz, Jerzy; Mikolajczak, Renata; Ziemnicka, Katarzyna; Gryczynska, Maria; Sowinski, Jerzy; Signore, Alberto

    2007-01-01

    Purpose Several new somatostatin analogues have been developed for the diagnosis and therapy of different tumours. Since somatostatin receptors are often over-expressed in medullary thyroid carcinoma (MTC), the aim of our study was to evaluate the utility of scintigraphy with the somatostatin

  5. Uptake kinetics of the somatostatin receptor ligand [{sup 86}Y]DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide ([{sup 86}Y]SMT487) using positron emission tomography in non-human primates and calculation of radiation doses of the {sup 90}Y-labelled analogue

    Energy Technology Data Exchange (ETDEWEB)

    Roesch, F.; Brockmann, J. [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Nuklearchemie; Herzog, H.; Muehlensiepen, H.; Mueller-Gaertner, H.W. [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Medizin; Stolz, B.; Marbach, P. [Novartis Pharma AG, Basel (Switzerland); Koehle, M. [Klinikum der Freien Universitaet Berlin (Germany)

    1999-04-29

    [{sup 90}Y]DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide ([{sup 90}Y]-SMT487) has been suggested as a promising radiotherapeutic agent for somatostatin receptor-expressing tumours. In order to quantify the in vivo parameters of this compound and the radiation doses delivered to healthy organs, the analogue [{sup 86}Y]DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide was synthesised and its uptake measured in baboons using positron emission tomography (PET). [{sup 86}Y]DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide was administered at two different peptide concentrations, namely 2 and 100 {mu}g peptide per m{sup 2} body surface. The latter concentration corresponded to a radiotherapeutic dose. In a third protocol [{sup 86}Y]DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide was injected in conjunction with a simultaneous infusion of an amino acid solution that was high in l-lysine in order to lower the renal uptake of radioyttrium. Quantitative whole-body PET scans were recorded to measure the uptake kinetics for kidneys, liver, lung and bone. The individual absolute uptake kinetics were used to calculate the radiation doses for [{sup 90}Y]DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide according to the MIRD recommendations extrapolated to a 70-kg human. The highest radiation dose was received by the kidneys, with 2.1-3.3 mGy per MBq [{sup 90}Y]DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide injected. For the 100 {mu}g/m{sup 2} SMT487 protocol with amino acid co-infusion this dose was about 20%-40% lower than for the other two treatment protocols. The liver and the red bone marrow received doses ranging from 0.32 to 0.53 mGy and 0.03 to 0.07 mGy per MBq [{sup 90}Y]DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide, respectively. The average effective dose equivalent amounted to 0.23-0.32 mSv/MBq. The comparatively low estimated radiation doses to normal organs support the initiation of clinical phase I trials with [{sup 90}Y]DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide in patients with somatostatin receptor-expressing tumours. (orig

  6. Cysteamine induces cholecystokinin release from the duodenum. Evidence for somatostatin as an inhibitory paracrine regulator of cholecystokinin secretion in the rat

    International Nuclear Information System (INIS)

    Abucham, J.; Reichlin, S.

    1990-01-01

    To determine whether cholecystokinin secretion is regulated by endogenous somatostatin, somatostatin deficiency was induced in vivo with cysteamine (250 mg/kg body wt, IV) or anti-somatostatin antiserum in anaesthetized rats and in vitro with cysteamine (30 micrograms/mL) in a rat duodenum-incubation system. Cholecystokinin secretion was assessed in vivo by measuring amylase in duodenal perfusates collected at 10-minute intervals for 1 hour and in vitro by a carboxy-terminal radioimmunoassay. Cysteamine induced a marked decrease in duodenal immunoreactive somatostatin both in vivo (50%) and in vitro (60%). The rate of amylase secretion increased from 9.7 +/- 2.1 U (mean +/- SE) to 28.0 +/- 4.8 U at 20 minutes (P less than 0.001). The cholecystokinin-receptor antagonist CR-1392 abolished amylase response for 30 minutes, whereas the more potent antagonists Asperlicin (18.0 mg/kg body wt, IV) and L-364,718 (0.25 mg/kg body wt, IV) caused prolonged blockade. The rate of amylase secretion in gastrectomized animals increased from 7.2 +/- 2.0 U to 15.0 +/- 2.2 U 20 minutes after cysteamine administration (P less than 0.01), indicating that the effect was not due to the presence of gastrin. In vitro, cysteamine caused a nearly fourfold increase in cholecystokinin secretion compared with controls (63.1 +/- 4.9 vs. 15.2 +/- 3.7, respectively; P less than 0.001). In vivo immunoneutralization of circulating somatostatin with a high-affinity and high-capacity antiserum produced no significant change in the rate of amylase secretion. These results suggest that cholecystokinin secretion is tonically inhibited by somatostatin and that this effect is mediated by locally secreted (paracrine) but not by circulating somatostatin

  7. Targeting either GH or IGF-I during somatostatin analogue treatment in patients with acromegaly

    DEFF Research Database (Denmark)

    Dal, Jakob; Klose, Marianne; Heck, Ansgar

    2018-01-01

    CONTEXT: Discordant GH and IGF-I values are frequent in acromegaly. The clinical significance and its dependence on treatment modality and of glucose-suppressed GH (GHnadir) measurements remain uncertain. OBJECTIVE: To evaluate the effects of targeting either IGF-I or GH during somatostatin analog...... (SA) treatment. PATIENTS AND METHODS: 84 patients with controlled acromegaly after surgery (n=23) or SA (n=61) underwent a GH-profile including an OGTT, at baseline and after 12 months. SA patients were randomized to monitoring according to either IGF-I (n= 33) or GHnadir (n=28). SA dose escalation...

  8. Hilar somatostatin interneuron loss reduces dentate gyrus inhibition in a mouse model of temporal lobe epilepsy.

    Science.gov (United States)

    Hofmann, Gabrielle; Balgooyen, Laura; Mattis, Joanna; Deisseroth, Karl; Buckmaster, Paul S

    2016-06-01

    In patients with temporal lobe epilepsy, seizures usually start in the hippocampus, and dentate granule cells are hyperexcitable. Somatostatin interneurons are a major subpopulation of inhibitory neurons in the dentate gyrus, and many are lost in patients and animal models. However, surviving somatostatin interneurons sprout axon collaterals and form new synapses, so the net effect on granule cell inhibition remains unclear. The present study uses optogenetics to activate hilar somatostatin interneurons and measure the inhibitory effect on dentate gyrus perforant path-evoked local field potential responses in a mouse model of temporal lobe epilepsy. In controls, light activation of hilar somatostatin interneurons inhibited evoked responses up to 40%. Epileptic pilocarpine-treated mice exhibited loss of hilar somatostatin interneurons and less light-induced inhibition of evoked responses. These findings suggest that severe epilepsy-related loss of hilar somatostatin interneurons can overwhelm the surviving interneurons' capacity to compensate by sprouting axon collaterals. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  9. Somatostatin-Immunoreactive Pancreaticoduodenal Neuroendocrine Neoplasms

    DEFF Research Database (Denmark)

    Engelund Luna, Iben; Monrad, Nina; Binderup, Tina

    2016-01-01

    , and biochemical features as well as treatment and prognosis. DESIGN: Twenty-three patients with p-dSOM (9 duodenal, 12 pancreatic, 2 unknown primary tumour) were identified from our prospective neuroendocrine tumour (NET) database, and data according to the study aims were recorded. RESULTS: Of the 9 patients...... with duodenal SOM the m/f ratio was 4/5. All males and one female had NF-1. Seven patients had stage 1A-B and 2 had stage 2B disease. The Ki-67 index was 1-5% (median 2%). Plasma somatostatin was elevated in patients with 2B disease. Of the 14 patients with pancreatic SOM or unknown primary tumour the m/f ratio...... was 2/12. One male had MEN-1. Five had stage 1A-2B and nine had stage 4. The Ki-67 index was 1-40% (median 7%). Plasma somatostatin was elevated in seven patients. Patients reported symptoms related to the somatostatinoma syndrome, but none fulfilled the criteria for a full syndrome. Primary tumour...

  10. Correlation of Somatostatin Receptor-2 Expression with Gallium-68-DOTA-TATE Uptake in Neuroblastoma Xenograft Models.

    Science.gov (United States)

    Zhang, Libo; Vines, Douglass C; Scollard, Deborah A; McKee, Trevor; Komal, Teesha; Ganguly, Milan; Do, Trevor; Wu, Bing; Alexander, Natasha; Vali, Reza; Shammas, Amer; Besanger, Travis; Baruchel, Sylvain

    2017-01-01

    Peptide-receptor imaging and therapy with radiolabeled somatostatin analogs such as 68 Ga-DOTA-TATE and 177 Lu-DOTA-TATE have become an effective treatment option for SSTR-positive neuroendocrine tumors. The purpose of this study was to evaluate the correlation of somatostatin receptor-2 (SSTR2) expression with 68 Ga-DOTA-TATE uptake and 177 Lu-DOTA-TATE therapy in neuroblastoma (NB) xenograft models. We demonstrated variable SSTR2 expression profiles in eight NB cell lines. From micro-PET imaging and autoradiography, a higher uptake of 68 Ga-DOTA-TATE was observed in SSTR2 high-expressing NB xenografts (CHLA-15) compared to SSTR2 low-expressing NB xenografts (SK-N-BE(2)). Combined autoradiography-immunohistochemistry revealed histological colocalization of SSTR2 and 68 Ga-DOTA-TATE uptake in CHLA-15 tumors. With a low dose of 177 Lu-DOTA-TATE (20 MBq/animal), tumor growth inhibition was achieved in the CHLA-15 high SSTR2 expressing xenograft model. Although, in vitro , NB cells showed variable expression levels of norepinephrine transporter (NET), a molecular target for 131 I-MIBG therapy, low 123 I-MIBG uptake was observed in all selected NB xenografts. In conclusion, SSTR2 expression levels are associated with 68 Ga-DOTA-TATE uptake and antitumor efficacy of 177 Lu-DOTA-TATE. 68 Ga-DOTA-TATE PET is superior to 123 I-MIBG SPECT imaging in detecting NB tumors in our model. Radiolabeled DOTA-TATE can be used as an agent for NB tumor imaging to potentially discriminate tumors eligible for 177 Lu-DOTA-TATE therapy.

  11. Correlation of Somatostatin Receptor-2 Expression with Gallium-68-DOTA-TATE Uptake in Neuroblastoma Xenograft Models

    Directory of Open Access Journals (Sweden)

    Libo Zhang

    2017-01-01

    Full Text Available Peptide-receptor imaging and therapy with radiolabeled somatostatin analogs such as 68Ga-DOTA-TATE and 177Lu-DOTA-TATE have become an effective treatment option for SSTR-positive neuroendocrine tumors. The purpose of this study was to evaluate the correlation of somatostatin receptor-2 (SSTR2 expression with 68Ga-DOTA-TATE uptake and 177Lu-DOTA-TATE therapy in neuroblastoma (NB xenograft models. We demonstrated variable SSTR2 expression profiles in eight NB cell lines. From micro-PET imaging and autoradiography, a higher uptake of 68Ga-DOTA-TATE was observed in SSTR2 high-expressing NB xenografts (CHLA-15 compared to SSTR2 low-expressing NB xenografts (SK-N-BE(2. Combined autoradiography-immunohistochemistry revealed histological colocalization of SSTR2 and 68Ga-DOTA-TATE uptake in CHLA-15 tumors. With a low dose of 177Lu-DOTA-TATE (20 MBq/animal, tumor growth inhibition was achieved in the CHLA-15 high SSTR2 expressing xenograft model. Although, in vitro, NB cells showed variable expression levels of norepinephrine transporter (NET, a molecular target for 131I-MIBG therapy, low 123I-MIBG uptake was observed in all selected NB xenografts. In conclusion, SSTR2 expression levels are associated with 68Ga-DOTA-TATE uptake and antitumor efficacy of 177Lu-DOTA-TATE. 68Ga-DOTA-TATE PET is superior to 123I-MIBG SPECT imaging in detecting NB tumors in our model. Radiolabeled DOTA-TATE can be used as an agent for NB tumor imaging to potentially discriminate tumors eligible for 177Lu-DOTA-TATE therapy.

  12. Switch from antagonist to agonist after addition of a DOTA chelator to a somatostatin analog

    International Nuclear Information System (INIS)

    Reubi, Jean Claude; Cescato, Renzo; Waser, Beatrice; Erchegyi, Judit; Rivier, Jean E.

    2010-01-01

    Peptide receptor targeting has become an increasingly attractive method to target tumors diagnostically and radiotherapeutically. Peptides linked to a variety of chelators have been developed for this purpose. They have, however, rarely been tested for their agonistic or antagonistic properties. We report here on a somatostatin antagonist that switched to an agonist upon coupling to a DOTA chelator. Two novel somatostatin analogs, 406-040-15 and its DOTA-coupled counterpart 406-051-20, with and without cold Indium labeling, were tested for their somatostatin receptor subtypes 1-5 (sst 1 -sst 5 ) binding affinity using receptor autoradiography. Moreover, they were tested functionally for their ability to affect sst 2 and sst 3 internalization in vitro in HEK293 cells stably expressing the human sst 2 or sst 3 receptor, using an immunofluorescence microscopy-based internalization assay. All three compounds were characterized as pan-somatostatin analogs having a high affinity for all five sst. In the sst 2 internalization assay, all three compounds showed an identical behavior, namely, a weak agonistic effect complemented by a weak antagonistic effect, compatible with the behavior of a partial agonist. Conversely, in the sst 3 internalization assay, 406-040-15 was a full antagonist whereas its DOTA-coupled counterpart, 406-051-20, with and without Indium labeling, switched to a full agonist. Adding the DOTA chelator to the somatostatin analog 406-040-15 triggers a switch at sst 3 receptor from an antagonist to an agonist. This indicates that potential radioligands for tumor targeting should always be tested functionally before further development, in particular if a chelator is added. (orig.)

  13. Activation of Brain Somatostatin Signaling Suppresses CRF Receptor-Mediated Stress Response

    OpenAIRE

    Andreas Stengel; Yvette F. Taché; Yvette F. Taché

    2017-01-01

    Corticotropin-releasing factor (CRF) is the hallmark brain peptide triggering the response to stress and mediates—in addition to the stimulation of the hypothalamus-pituitary-adrenal (HPA) axis—other hormonal, behavioral, autonomic and visceral components. Earlier reports indicate that somatostatin-28 injected intracerebroventricularly counteracts the acute stress-induced ACTH and catecholamine release. Mounting evidence now supports that activation of brain somatostatin signaling exerts a br...

  14. Somatostatin-receptor imaging in the localization of endocrine tumors

    International Nuclear Information System (INIS)

    Lamberts, S.W.; Bakker, W.H.; Reubi, J.C.; Krenning, E.P.

    1990-01-01

    A number of different tumors have receptors for somatostatin. We evaluated the efficacy of scanning with 123 I-labeled Tyr3-octreotide, a somatostatin analogue, for tumor localization in 42 patients with carcinoid tumors, pancreatic endocrine tumors, or paragangliomas. We then evaluated the response to octreotide therapy in some of these patients. Primary tumors or metastases, often previously unrecognized, were visualized in 12 of 13 patients with carcinoid tumors and in 7 of 9 patients with pancreatic endocrine tumors. The endocrine symptoms of these patients responded well to therapy with octreotide. Among 20 patients with paragangliomas, 8 of whom had more than one tumor, 10 temporal (tympanic or jugular), 9 carotid, and 10 vagal tumors could be visualized. One small tympanic tumor and one small carotid tumor were not seen on the scan. The 123 I-labeled Tyr3-octreotide scanning technique is a rapid and safe procedure for the visualization of some tumors with somatostatin receptors. A positive scan may predict the ability of octreotide therapy to control symptoms of hormonal hypersecretion

  15. EFFICIENCY OF THE ACROMEGALIC PATIENTS’ TREATMENT WITH DIFFERENT DOSES OF SANDOSTATIN LAR IN MOSCOW REGION

    Directory of Open Access Journals (Sweden)

    A. V. Dreval’

    2014-01-01

    Full Text Available Background: Somatostatin analogues therapy is an important part of the acromegalic patients’ treatment. Aim: Assessment of treatment efficiency for patients with acromegaly using different doses of somatostatin analogues. Materials and methods: The data of 128 acromegaly patients registered in Moscow Region were analyzed, 79 (61.7% of them were treated with somatostatin analogues. The treatment was started with a dose of 20 mg. If the target levels of growth hormone (GH and type 1 insulin-like growth factor (IGF-1 were not achieved within 6-12 months, the dose was increased to 30 mg, and then to 40 mg. If GH and IGF-1 levels fell under the target values, the dose was decreased to 10 mg. The rate of achievement of optimal GH and IGF-1 levels was analyzed depending on the somatostatin analogue doses used. Results: The percentage of the acromegalic patients who were under the first and the second lines of drug therapy, was almost similar:  55.7 and 44.3%, respectively. Sandostatin LAR in dose of 10 mg was given to 4 (5.1% of 79 patients, 20 mg – to 33 (41.8%, 30 mg – to 11 (13.9%, and 40 mg – to 31 (39.2% patients. The target levels of GH and IGF-1 were achieved in 57.6, 54.5, and 32.2% of patients, who received preparation in doses 20, 30, and 40 mg, respectively. Achievement of, at least, one planned criterium (GH or IGF-1 was additionally noted in 10 of 33 (30.3%, 4 of 11 (36.2%, and 9 of 31 (29% patients within these study groups. The rate of side effects didn’t increase with the raising of оctreotide dose. Conclusion: Application of long-acting release octreotide (Sandostatin-LAR in doses of 30 and 40 mg is safe and allows to increase percentage of acromegalic patients who achieve a biochemical control over acromegaly.

  16. Radiolabeled somatostatin analog scintigraphy in oncology and immune diseases: an overview

    International Nuclear Information System (INIS)

    Kwekkeboom, D.J.; Krenning, E.P.

    1997-01-01

    [ 111 In-DTPA-D-Phe 1 [-octreotide is a new radiopharmaceutical with a great potential for the visualization of somatostatin receptor-positive tumors, granulomas, and diseases in which activated leukocytes play a role. The overall sensitivity of [ 111 In-DTPA-D-Phe 1 [-octreotide scintigraphy to localize neuroendocrine tumors is high. In several neuroendocrine tumor types, inclusion of somatostatin receptor imaging in the localization or staging procedure may be very rewarding, either in terms of cost-effectiveness, patient management, or quality of life. In our opinion, this holds true for patients with carcinoids, gastrinomas, paragangliomas, small-cell lung carcinoma, and selected cases of patients with insulinomas. The value of [ 111 In-DTPA-D-Phe 1 [-octreotide scintigraphy in patients with other tumors, such as breast cancer, malignant lymphomas, or in patients with granulomatous diseases, has to be established. (orig.). With 4 figs., 1 tab

  17. In vitro effect of. Delta. sup 9 -tetrahydrocannabinol to stimulate somatostatin release and block that of luteinizing hormone-releasing hormone by suppression of the release of prostaglandin E sub 2

    Energy Technology Data Exchange (ETDEWEB)

    Rettori, V.; Aguila, M.C.; McCann, S.M. (Univ. of Texas Southwestern Medical Center at Dallas (United States)); Gimeno, M.F.; Franchi, A.M. (Centro de Estudios Farmacologicos y de Principios Naturales, Buenos Aires (Argentina))

    1990-12-01

    Previous in vivo studies have shown that {Delta}{sup 9}-tetrahydrocannabinol (THC), the principal active ingredient in marijuana, can suppress both luteinizing hormone (LH) and growth hormone (GH) secretion after its injection into the third ventricle of conscious male rats. The present studies were deigned to determine the mechanism of these effects. Various doses of THC were incubated with either stalk median eminence fragments (MEs) or mediobasal hypothalamic (MBH) fragments in vitro. Although THC (10 nM) did not alter basal release of LH-releasing hormone (LHRH) from MEs in vitro, it completely blocked the stimulatory action of dopamine or nonrepinephrine on LHRH release. The effective doses to block LHRH release were associated with a blockade of synthesis and release of prostaglandin E{sub 2} (PGE{sub 2}) from MBH in vitro. In contrast to the suppressive effect of THC on LHRH release, somatostatin release from MEs was enhanced in a dose-related manner with a minimal effective dose of 1 nM. Since PGE{sub 2} suppresses somatostatin release, this enhancement may also be related to the suppressive effect of THC on PGE{sub 2} synthesis and release. The authors speculate that these actions are mediated by the recently discovered THC receptors in the tissue. The results indicate that the suppressive effect of THC on LH release is mediated by a blockade of LHRH release, whereas the suppressive effect of the compound on growth hormone release is mediated, at least in part, by a stimulation of somatostatin release.

  18. Pertussis toxin inhibits somatostatin-induced K+ conductance in human pituitary tumor cells

    International Nuclear Information System (INIS)

    Yamashita, N.; Kojima, I.; Shibuya, N.; Ogata, E.

    1987-01-01

    The effect of pertussis toxin on somatostatin-induced K + current was examined in dissociated human pituitary tumor cells obtained from two acromegalic patients. Somatostatin-induced hyperpolarization or K + current was observed in 20 of 23 cells in adenoma 1 and 10 of 11 cells in adenoma 2. After treatment with pertussis toxin for 24 h, these responses were completely suppressed (0/14 in adenoma, 1, 0/10 in adenoma 2). Spontaneous action potentials, K + , Na + , and Ca 2+ currents were well preserved after pertussis toxin treatment. When crude membrane fraction was incubated with [ 32 P]NAD, a 41K protein was ADP-ribosylated by pertussis toxin. Hormone release was inhibited by somatostatin and this inhibition was blocked by pertussis toxin treatment

  19. Somatostatin receptor scintigraphy on thyroid carcinoma

    International Nuclear Information System (INIS)

    Pan Weimin; Tan Tianzhi

    2004-01-01

    Purpose: To study the diagnostic value and clinical method of somatostatin receptor scintigraphy on thyroid carcinoma using 99 Tc m -RC-160 labeled with direct method as scintigraphy reagent; Methods: Somatostatin receptor scintigraphy (SRS) were performed on 25 patients with thyroid carcinoma, using 99 Tc m -RC-160 labeled with direct method as scintigraphy reagent, controlling with 131 I- whole- body- imaging(1312 -WBI). Results: Of 4 patients with MTC (medullary thyroid carcinoma), positive metastasis and primary tumour were detected on 3 patients by SRS, negative results were obtained by 131 I-WBI, the positive detective rate by SRS is 3/4; of 12 patients with PTC (papillary thyroid carcinoma), positive metastasis and primary tumour were detected on 2 patients by SRS or 131 I-WBI,1 of which only by SRS, while negative results were obtained by 131 I- WBI, the positive detective rate by SRS is 3/12; of 8 patients with FTC(follicular thyroid carcinoma), positive metastasis and primary tumour were detected on 1 patients by SRS or 131 I-WBI, and 2 positive results were obtained only by SRS, while negative by 131 I-WBI, the positive detective rate by SRS is 3/8; of 1 patients with HCC (hurthle cell carcinoma ), positive metastasis and primary tumour were detected by SRS, while negative by 131 I-WBI; Conclusions: SRS using 99 Tc m -RC-160 labeled with direct method as scintigraphy reagent has high diagnostic value on thyroid carcinoma, especially on MTC and HCC. (authors)

  20. Immunohistochemical detection of somatostatin receptor subtypes sst1 and sst2A in human somatostatin receptor positive tumors

    NARCIS (Netherlands)

    L.J. Hofland (Leo); Q. Liu; P.M. van Koetsveld (Peter); J. Zuijderwijk; F. van der Ham (Frieda); R.R. de Krijger (Ronald); A. Schonbrunn; S.W.J. Lamberts (Steven)

    1999-01-01

    textabstractAlthough in situ hybridization has been used to examine the distribution of messenger RNA for somatostatin receptor subtypes (sst) in human tumors, the cellular localization of sst1 and sst2A receptors has not been reported. In this study, we describe the

  1. Effects of cysteamine on dopamine-mediated behaviors: evidence for dopamine-somatostatin interactions in the striatum

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Iverson, M.T.; Radke, J.M.; Vincent, S.R.

    1986-06-01

    The effects of prior treatment with cysteamine, a drug which appears to deplete selectively the neuropeptide somatostatin, on apomorphine-induced stereotypy and amphetamine-induced locomotor activity and conditioned place preferences were investigated. Twelve hours following systemic cysteamine injections apomorphine-induced stereotypy was attenuated and striatal somatostatin levels were reduced by half. Systemic cysteamine also decreased the motor stimulant effects of amphetamine, without influencing the rewarding properties as determined by the conditioned place preference procedure. Direct injections of cysteamine into the nucleus accumbens also decreased the locomotor response to amphetamine, and produced a local reduction in somatostatin levels in the accumbens. Cysteamine did not appear to alter monoamine turnover in the striatum after either systemic or intra-accumbens injections. These results suggest that somatostatin in the nucleus accumbens and caudate-putamen modulates the motor, but not the reinforcing properties of dopaminergic drugs, possibly via an action postsynaptic to dopamine-releasing terminals. Furthermore, it is evident from these results that cysteamine is an important tool with which to study the central actions of somatostatin.

  2. Carboxyl-terminal multi-site phosphorylation regulates internalization and desensitization of the human sst2 somatostatin receptor.

    Science.gov (United States)

    Lehmann, Andreas; Kliewer, Andrea; Schütz, Dagmar; Nagel, Falko; Stumm, Ralf; Schulz, Stefan

    2014-04-25

    The somatostatin receptor 2 (sst2) is the pharmacological target of somatostatin analogs that are widely used in the diagnosis and treatment of human neuroendocrine tumors. We have recently shown that the stable somatostatin analogs octreotide and pasireotide (SOM230) stimulate distinct patterns of sst2 receptor phosphorylation and internalization. Like somatostatin, octreotide promotes the phosphorylation of at least six carboxyl-terminal serine and threonine residues namely S341, S343, T353, T354, T356 and T359, which in turn leads to a robust receptor endocytosis. Unlike somatostatin, pasireotide stimulates a selective phosphorylation of S341 and S343 of the human sst2 receptor followed by a partial receptor internalization. Here, we show that exchange of S341 and S343 by alanine is sufficient to block pasireotide-driven internalization, whereas mutation of T353, T354, T356 and T359 to alanine is required to strongly inhibited both octreotide- and somatostatin-induced internalization. Yet, combined mutation of T353, T354, T356 and T359 is not sufficient to prevent somatostatin-driven β-arrestin mobilization and receptor desensitization. Replacement of all fourteen carboxyl-terminal serine and threonine residues by alanine completely abrogates sst2 receptor internalization and β-arrestin mobilization in HEK293 cells. Together, our findings demonstrate for the first time that agonist-selective sst2 receptor internalization is regulated by multi-site phosphorylation of its carboxyl-terminal tail. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Somatostatin and serum gastrin in normal subjects and in patients with pernicious anaemia, chronic liver and renal disease

    Energy Technology Data Exchange (ETDEWEB)

    Le Roith, D; Vinik, A I; Epstein, S; Baron, P; Olkenitzky, M N; Pimstone, B L

    1975-09-13

    The effects of somatostatin (growth hormone release inhibiting hormone) on basal gastrin were studied in patients suffering from pernicious anaemia and chronic renal and liver disease, and during sequential arginine/insulin-stimulated gastrin release in normal subjects. When basal gastrin concentrations were normal (10-50 pg/ml) in controls and in patients who were in renal and liver failure, somatostatin had no effect on gastrin levels. Raised basal gastrin levels in pernicious anaemia and in 2 cases of chronic renal disease, were significantly inhibited by somatostatin with a half-life (T-half) of 3 to 4 minutes. Arginine infusion caused an insignificant rise in serum gastrin which was unaffected by somatostatin, whereas insulin hypoglycaemia significantly stimulated gastrin release, which was inhibited by somatostatin.

  4. Plasma growth hormone response to human growth hormone releasing factor in rats administered with chlorpromazine and antiserum against somatostatin. Effects of hypo- and hyperthyroidism.

    Science.gov (United States)

    Wakabayashi, I; Tonegawa, Y; Ihara, T; Hattori, M; Shibasaki, T; Ling, N

    1985-10-01

    The effect of hypo- and hyperthyroidism on the plasma growth hormone (GH) response to synthetic human growth hormone releasing factor (GRF) was determined in conscious, freely moving rats pretreated with chlorpromazine and antiserum against somatostatin. Chlorpromazine plus somatostatin antiserum pretreated rats gave consistent response to GRF which was not observed in untreated rats. Chlorpromazine alone has no effect on GH secretion induced by GRF in rat pituitary monolayer culture. In rats made hypothyroid by thyroidectomy, both basal and peak plasma GH responses to a small (0.25 microgram/kg bw) and a moderate dose of GRF (1 microgram/kg bw) were significantly reduced as compared to controls. In rats made hyperthyroid by the administration of thyroxine, basal and peak plasma GH responses to a small but not to a moderate dose of GRF were significantly reduced as compared to controls. A reduced plasma GH response to a small dose of GRF was observed 8 days after the cessation of thyroxine administration. The pituitary GH reserve was markedly reduced in hypothyroid but not in hyperthyroid rats as compared to their respective controls. These results indicate that plasma GH response to GRF is reduced both in hypo- and hyperthyroidism. The mechanism involved in the phenomenon appears to be different between the two conditions.

  5. Somatostatin receptor imaging in intracranial tumours

    International Nuclear Information System (INIS)

    Schmidt, M.; Scheidhauer, K.; Voth, E.; Schicha, H.; Luyken, C.; Hildebrandt, G.; Klug, N.

    1998-01-01

    The somatostatin analogue [ 111 In-DTPA-d-Phe 1 ]-octreotide ( 111 In-octreotide) allows scintigraphic visualization of somatostatin receptor-expressing tissue. While it is well known that a large variety of tissues express somatostatin receptors and 111 In-octreotide scintigraphy has a clearly defined role in various neuroendocrine diseases, the clinical value of 111 In-octreotide scintigraphy in brain tumours is still under clinical investigation. In 124 patients with 141 brain lesions (63 meningiomas, 24 pituitary adenomas, 10 gliomas WHO class I and II, 12 gliomas WHO class III and IV, 11 neurinomas and 2 neurofibromas, 7 metastases and 12 other varieties: three non-Hodgkin B-cell lymphomas, two epidermoids, one abscess, one angioleiomyoma, one chordoma, one haemangiopericytoma, one osteosarcoma, one plasmacytoma and one pseudocyst), 111 In-octreotide scintigraphy was performed 4-6 and 24 h after i.v. injection of 110-220 MBq 111 In-octreotide. Planar images of the head in four views with a 128 x 128 matrix and single-photon emission tomographic images (64 x 64 matrix) were acquired, and lesions were graded according to qualitative tracer uptake. Fifty-nine of the 63 meningiomas showed moderate to intense tracer uptake. Nine of 24 pituitary adenomas were visible; the remaining 15 did not show any tracer uptake. None of the class I and II gliomas with an intact blood-brain barrier were detected whereas 11/12 class III and IV gliomas showed 111 In-octreotide uptake. None of the neurinomas or neurofibromas were positive. Five of seven metastases were classified as positive, as were the osteosarcoma, two of three non-Hodgkin B-cell lymphomas, one abscess, one angioleiomyoma, one chordoma and one haemangiopericytoma. The other varieties (one non-Hodgkin B-cell lymphoma, two epidermoids, one plasmacytoma and one pseudocyst) did not show 111 In-octreotide uptake. The results demonstrate that a large variety of intracranial lesions express somatostatin receptors and

  6. Somatostatin receptor imaging in intracranial tumours

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, M.; Scheidhauer, K.; Voth, E.; Schicha, H. [Department of Nuclear Medicine, University of Koeln (Germany); Luyken, C.; Hildebrandt, G.; Klug, N. [Department of Neurosurgery, University of Kolen (Germany)

    1998-07-01

    The somatostatin analogue [{sup 111}In-DTPA-d-Phe{sup 1}]-octreotide ({sup 111}In-octreotide) allows scintigraphic visualization of somatostatin receptor-expressing tissue. While it is well known that a large variety of tissues express somatostatin receptors and {sup 111}In-octreotide scintigraphy has a clearly defined role in various neuroendocrine diseases, the clinical value of {sup 111}In-octreotide scintigraphy in brain tumours is still under clinical investigation. In 124 patients with 141 brain lesions (63 meningiomas, 24 pituitary adenomas, 10 gliomas WHO class I and II, 12 gliomas WHO class III and IV, 11 neurinomas and 2 neurofibromas, 7 metastases and 12 other varieties: three non-Hodgkin B-cell lymphomas, two epidermoids, one abscess, one angioleiomyoma, one chordoma, one haemangiopericytoma, one osteosarcoma, one plasmacytoma and one pseudocyst), {sup 111}In-octreotide scintigraphy was performed 4-6 and 24 h after i.v. injection of 110-220 MBq {sup 111}In-octreotide. Planar images of the head in four views with a 128 x 128 matrix and single-photon emission tomographic images (64 x 64 matrix) were acquired, and lesions were graded according to qualitative tracer uptake. Fifty-nine of the 63 meningiomas showed moderate to intense tracer uptake. Nine of 24 pituitary adenomas were visible; the remaining 15 did not show any tracer uptake. None of the class I and II gliomas with an intact blood-brain barrier were detected whereas 11/12 class III and IV gliomas showed {sup 111}In-octreotide uptake. None of the neurinomas or neurofibromas were positive. Five of seven metastases were classified as positive, as were the osteosarcoma, two of three non-Hodgkin B-cell lymphomas, one abscess, one angioleiomyoma, one chordoma and one haemangiopericytoma. The other varieties (one non-Hodgkin B-cell lymphoma, two epidermoids, one plasmacytoma and one pseudocyst) did not show {sup 111}In-octreotide uptake. The results demonstrate that a large variety of intracranial

  7. GH and IGF-I induction by passive immunization of rainbow trout Oncorhynchus mykiss Walbaum using a somatostatin 14 antibody

    Science.gov (United States)

    Inhibition of the growth axis by somatostatin was studied in juvenile rainbow trout using passive immunization with a previously isolated somatostatin antibody (antiSS-14). Upon subcutaneously injection of laying hens (Gallus domesticus) with conjugated somatostatin-14 (SS-14), the antiSS-14 was iso...

  8. Somatostatin analogue scintigraphy and tuberculosis: case report

    International Nuclear Information System (INIS)

    Biancheri, I.; Rudenko, B.; Vautrin, P.; Raddoul, J.; Lamfichek, N.; Kantelip, B.; Mantion, G.

    2005-01-01

    Scintigraphy using a radiolabelled somatostatin analogue (111 In-pentetreotide) is useful in the detection of neuroendocrine tumors. But this radiopharmaceutical accumulates also in solid tumours or in inflammatory diseases such as granulomatosis. We present a case of 111 In-pentetreotide uptake in a tuberculous adenopathy. (author)

  9. Somatostatin-IRES-Cre Mice: Between Knockout and Wild-Type?

    Science.gov (United States)

    Viollet, Cécile; Simon, Axelle; Tolle, Virginie; Labarthe, Alexandra; Grouselle, Dominique; Loe-Mie, Yann; Simonneau, Michel; Martel, Guillaume; Epelbaum, Jacques

    2017-01-01

    The neuropeptide somatostatin (SOM) is widely expressed in rodent brain and somatostatin-IRES-Cre (SOM-cre) mouse strains are increasingly used to unravel the physiology of SOM-containing neurons. However, while knock-in targeting strategy greatly improves Cre-Lox system accuracy, recent reports have shown that genomic insertion of Cre construct per se can markedly affect physiological function. We show that Cre transgene insertion into the 3'UTR of the somatostatin gene leads to the selective and massive depletion of endogenous SOM in all tested brain regions. It also strongly impacts SOM-related neuroendocrine responses in a similar manner to what has been reported for SST KO mice: increased corticosterone levels after 30-min restraint stress, decreased amplitude and regularity of ultradian growth hormone secretory patterns accompanied by changes in sexually dimorphic liver gene expression ( serpina1, Cyp2b9, Cyp2a4, Cyp2d9, and Cyp7b1 ). In addition to demonstrating the need for examination of the consequences of Cre transgenesis, these results also reveal how this SOM-cre strain may be a useful tool in studying the functional consequences of moderate to low SOM levels as reported in neurological and psychiatric disorders.

  10. 99m Tc- la bed somatostatin analogs for imaging somatostatin-receptor-positive tumors

    International Nuclear Information System (INIS)

    Gandomkar, M.; Najafi, R.; Shafiei, A.; Sadat Ebrahimi, E.; Babaie, M.H.; Rabani, M.

    2002-01-01

    Over the least few years, 111 In-DTPA- Octreotide has found widespread clinical applicability, especially in oncology. However limitation, especially concerning availability, imaging properties, and costs, remain and have stimulated research on radiolabeling with many alternative radionuclides. The purpose of this investigation was to labeling somatostatin analogs with 99 m Tc and evaluate their suitability as an agents for in vivo use. Octreotide and Tyr-3-Octreotide were labeled by 99 mTc with direct and indirect methods. Sodium ascorbate and sodium dithionite were used for reduction of cystine bridge and HYNIC was used as bifunctional agents and different co ligands used for labeling by 99 mTc. Yield of labeling, purity, stability, internalisation, binding affinity and biodistribution of peptide conjugates were studied. Direct labeling of octreotide was simple, rapid, efficient and yield was good (%60). K d for binding affinity as high (10 -9 ) but stability was low. Labeling for HYNIC-Tyr-Octreotide had a high yield (>%90), good stability, internalisation and biodistribution. with more experimental work and some improve this peptide-based radiopharmaceuticals can be employed in all nuclear medicine centers as a useful agent for imaging of tumors

  11. Localisation and mechanism of renal retention of radiolabelled somatostatin analogues

    Energy Technology Data Exchange (ETDEWEB)

    Melis, Marleen; Krenning, Eric P.; Bernard, Bert F.; Jong, Marion de [Erasmus MC, Department of Nuclear Medicine, Rotterdam (Netherlands); Barone, Raffaella [UCL, Centre of Nuclear Medicine and Laboratory of PET, Brussels (Belgium); Visser, Theo J. [Erasmus MC, Department of Internal Medicine, Rotterdam (Netherlands)

    2005-10-01

    Radiolabelled somatostatin analogues, such as octreotide and octreotate, are used for tumour scintigraphy and radionuclide therapy. The kidney is the most important critical organ during such therapy owing to the reabsorption and retention of radiolabelled peptides. The aim of this study was to investigate in a rat model both the localisation and the mechanism of renal uptake after intravenous injection of radiolabelled somatostatin analogues. The multi-ligand megalin/cubilin receptor complex, responsible for reabsorption of many peptides and proteins in the kidney, is an interesting candidate for renal endocytosis of these peptide analogues. For localisation studies, ex vivo autoradiography and micro-autoradiography of rat kidneys were performed 1-24 h after injection of radiolabelled somatostatin analogues and compared with the renal anti-megalin immunohistochemical staining pattern. To confirm a role of megalin in the mechanism of renal retention of [{sup 111}In-DTPA]octreotide, the effects of three inhibitory substances were explored in rats. Renal ex vivo autoradiography showed high cortical radioactivity and lower radioactivity in the outer medulla. The distribution of cortical radioactivity was inhomogeneous. Micro-autoradiography indicated that radioactivity was only retained in the proximal tubules. The anti-megalin immunohistochemical staining pattern showed a strong similarity with the renal [{sup 111}In-DTPA]octreotide ex vivo autoradiograms. Biodistribution studies showed that co-injection of positively charged d-lysine reduced renal uptake to 60% of control. Sodium maleate reduced renal [{sup 111}In-DTPA]octreotide uptake to 15% of control. Finally, cisplatin pre-treatment of rats reduced kidney uptake to 70% of control. Renal retention of [{sup 111}In-DTPA]octreotide is confined to proximal tubules in the rat kidney, in which megalin-mediated endocytosis may play an important part. (orig.)

  12. Effect of somatostatin on nonesterified fatty acid levels modifies glucose homeostasis during fasting

    International Nuclear Information System (INIS)

    Hendrick, G.K.; Frizzell, R.T.; Cherrington, A.D.

    1987-01-01

    In the 7-days fasted conscious dog, unlike the postabsorptive conscious dog, somatostatin infusion results in decreased levels of nonesterified fatty acids (NEFA) and increased glucose utilization (R d ) even when insulin and glucagon levels are held constant. The aim of this study was to determine whether NEFA replacement in such animals would prevent the increase in R d . In each of three protocols there was an 80-min tracer equilibration period, a 40-min basal period, and a 3-h test period. During the test period in the first protocol saline was infused, in the second protocol somatostatin was infused along with intraportal replacement amounts of insulin and glucagon (hormone replacement), while in the third protocol somatostatin plus the pancreatic hormones were infused with concurrent heparin plus Intralipid infusion. Glucose turnover was assessed using [3- 3 H]glucose. The peripheral levels of insulin, glucagon, and glucose were similar and constant in all three protocols; however, during somatostatin infusion, exogenous glucose infusion was necessary to maintain euglycemia. The NEFA level was constant during saline infusion and decreased in the hormone replacement protocol. In the hormone replacement plus NEFA protocol, the NEFA level did not change during the first 90-min period and then increased during the second 90-min period. After a prolonged fast in the dog, (1) somatostatin directly or indirectly inhibits adipose tissue NEFA release and causes a decrease in the plasma NEFA level, and (2) this decrease in the NEFA level causes an increase in R d

  13. Alterations in Somatostatin Cells and Biochemical Parameters Following Zinc Supplementation in Gastrointestinal Tissue of St reptozotocin-Induced Diabetic Rats

    International Nuclear Information System (INIS)

    Bolkent, Sema; Bolkent, Sehnaz; Yanardag, Refiye; Mutlu, Ozgur; Yildirim, Sukriye

    2006-01-01

    Chronic hyperglycemia in diabetes is a major causative factor of free radical generation which further leads to many secondary diabetic complications via the damage to cellular proteins, membrane lipids, and nucleic acids. Zinc is an essential trace element in all living systems and plays a structural role in many proteins and enzymes. Somatostatin is known to have inhibitory effects on various gastrointestinal functions. Therefore, we determined somatostatin protein production and secretion levels, and biochemical and light microscopical changes following zinc supplementation in the gastrointestinal tract of streptozotocin (STZ)-diabetic rats. The animals were divided into four groups: Group I: control (untreated) animals; Group II: control animals given zinc sulfate; Group III: diabetic animals; and Group IV: diabetic animals given zinc sulfate. Zinc sulfate was given to the animals by gavage at a daily dose of 100 mg/kg body weight for 60 days. Diabetes was induced by intraperitoneal (i.p.) injection of STZ in a single dose of 65 mg/kg. For histological studies, stomach and duodenum tissues were fixed in Bouin solution and sections stained with Masson’s trichrome and Periodic-Acid-Schiff. Tissue homogenates were used for protein, lipid peroxidation (LPO), glutathione (GSH), and nonenzymatic glycosylation (NEG) analyses. Zinc supplementation to the STZ-diabetic rats revealed the protective effect of zinc on these parameters. Zinc supplementation may contribute to prevent at least some complications of diabetes mellitus

  14. Clinical value of somatostatin receptor imaging in patients with suspected head and neck paragangliomas

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Matthias; Dietlein, Markus; Weber, Kerstin; Moka, Detlef; Schicha, Harald [Klinik und Poliklinik fuer Nuklearmedizin, Universitaet zu Koeln, Joseph-Stelzmann-Strasse 9, 50924 Koeln (Germany); Fischer, Eva; Michel, Olaf; Stennert, Eberhard [Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde, Universitaet zu Koeln, Koeln (Germany)

    2002-12-01

    Paragangliomas or glomus tumours of the head and neck region are rare somatostatin receptor-expressing neuroendocrine tumours. Precise preoperative diagnosis is of special importance in order to adequately weigh the potential benefit of the operation against the inherent risks of the procedure. In this study, the clinical value of somatostatin receptor imaging was assessed in 19 patients who underwent somatostatin receptor scintigraphy because of known or suspected paraganglioma of the head and neck region. The results were compared with the results of computed tomography and/or magnetic resonance imaging, histology and clinical follow-up. [{sup 111}In-DTPA-D-Phe{sup 1}]-octreotide scintigraphy was performed 4-6 and 24 h after i.v. injection of 140-220 MBq {sup 111}In-octreotide. Whole-body and planar images as well as single-photon emission tomography images were acquired and lesions were graded according to qualitative tracer uptake. Somatostatin receptor imaging was positive in nine patients, identifying paragangliomas for the first time in three patients and recurrent disease in six patients. In one patient, a second, previously unknown paraganglioma site was identified. Negative results were obtained in ten patients. These patients included one suffering from chronic hyperplastic otitis externa, one with granuloma tissue and an organised haematoma, one with an acoustic neuroma, one with an asymmetric internal carotid artery, two with ectasia of the bulbus venae jugularis and one with a jugular vein thrombosis. In two patients with a strong family history of paraganglioma, individual involvement could be excluded. In only one patient did somatostatin receptor imaging and magnetic resonance imaging yield false negative results in respect of recurrent paraganglioma tissue. It is concluded that somatostatin receptor scintigraphy provides important information in patients with suspected paragangliomas of the head and neck region and has a strong impact on further

  15. Somatostatin Receptor Scintigraphy Findings in a Patient with Metastatic Gastrinoma and MEN 1 Syndrome

    Directory of Open Access Journals (Sweden)

    Gözde Mütevelizade

    2011-12-01

    Full Text Available Liver metastases from neuroendocrine tumours frequently occur and significantly worsen their prognosis. Somatostatin receptor scintigraphy (SRS is a valuable method for the detection of somatostatin receptor-positive lesions like gastrinoma. In this case report, the importance of SRS to localize the primary tumor and the spread of disease is emphasized in a patient with neuroendocrine liver metastases. A 45-year-old man was admitted to hospital with multiple liver metastasis of neuroendocrine carcinoma. Somatostatin receptor scintigraphy showed multiple intense radiotracer uptakes in the liver and a focal tracer uptake at the right side of the upper abdominal region corresponding to duodenum or pancreas. Elevated serum gastrin levels confirmed the gastrinoma diagnosis. (MRT 2011;20:117-120

  16. Somatostatin Receptor SPECT/CT using 99mTc Labeled HYNIC-TOC Aids in Diagnosis of Primary Optic Nerve Sheath Meningioma.

    Science.gov (United States)

    Chandra, Piyush; Purandare, Nilendu; Shah, Sneha; Agrawal, Archi; Rangarajan, Venkatesh

    2017-01-01

    Primary optic nerve sheath meningiomas (ONSM) are rare, benign and slow growing tumor involving the intra-orbital/intra-canalicular segment of the optic nerve. Untreated, they can potentially lead to visual deterioration. Magnetic resonance (MR) is the gold standard imaging modality for diagnosing the entity. Often, a clinical dilemma exists to narrow the differential diagnosis of an enhancing intra-orbital mass on MR. Molecular imaging provides a high degree of precision in diagnosing meningioma in view of relatively high levels of somatostatin receptor expression by these tumors. The following case demonstrates the potential clinical utility of somatostatin receptor SPECT using 99m Tc- labeled HYNIC-TOC in clinical diagnosis of ONSM.

  17. Peptide receptor radionuclide therapy (PRRT) of neuroendocrine tumors: First comparative results using the somatostatin analogues Lu-177 DOTA-NOC and Lu-177 DOTA-TATE

    International Nuclear Information System (INIS)

    Wehrmann, C.; Senftleben, S.; Baum, R.P.

    2005-01-01

    Peptide receptor radionuclide therapy (PRRT) is used in our department since 5 years (approx. 400 applications) for the treatment of patients with metastatic neuroendocrine tumors. Of all known peptides, the somatostatin analogue DOTA-NOC shows in vitro the highest affinity to somatostatin receptors (sstr) 3 and 5 and a very high affinity to sstr 2. We studied the in vivo behaviour of the two peptides DOTA-NOC and DOTA-TATE (highest affinity to sstr 2) by the use of different parameters like tumor and organ uptake, effective half-lifes (kinetics) and mean absorbed organ and tumor doses. We studied 27 patients with metastatic neuroendocrine tumors with high somatostatin expression, as verified prior to treatment by Ga-68 DOTA-NOC receptor PET/CT or somatostatin receptor scintigraphy (Tc-99m EDDA-Hynic TOC or In-111 OctreoScan, planar and SPECT). 22 patients (8M and 14F; aged 619 years) were treated with 2500 6790 MBq Lu-177 DOTA-TATE. Another 5 patients (1M and 4F, aged 6310 years) were treated with 4000 7400 MBq Lu-177 DOTA-NOC. Labelling efficiency and radiochemical purity using Lutetium-177 chloride (obtained from PerkinElmer Life Sciences, USA) were constantly over 99.5%. Whole-body scans (anterior/posterior) were performed at 0.5h, 3h, 24h, 48h, 72h and 96h p.i. ROIs were drawn over the whole-body, organs, and different metastases (mainly in the liver). Blood samples were obtained in 12 patients after therapy with Lu-177 DOTA-TATE over 5 days for calculating the kinetics in blood. The ROI results were used to determine the uptake and effective half-life in different organs (kidney, spleen, liver, bone etc.) and the tumor residence times. By means of geometric mean, and after background correction, the ROI results were also used to calculate the estimated absorbed organ and tumor doses using the OLINDA software. Compared to Lu-177 DOTA-TATE (=100%), the uptake of Lu-177 DOTA-NOC was higher for the whole-body (45%) and for normal tissues (28%), and also in the

  18. Somatostatin-immunoreactive senile plaque-like structures in the frontal cortex and nucleus accumbens of aged tree shrews and Japanese macaques.

    Science.gov (United States)

    Yamashita, Akiko; Fuchs, Eberhard; Taira, Masato; Yamamoto, Takamitsu; Hayashi, Motoharu

    2012-06-01

    Previously, we demonstrated decreased expression of somatostatin mRNA in aged macaque brain, particularly in the prefrontal cortex. To investigate whether or not this age-dependent decrease in mRNA is related to morphological changes, we analyzed somatostatin cells in the cerebra of aged Japanese macaques and compared them with those in rats and tree shrews, the latter of which are closely related to primates. Brains of aged macaques, tree shrews, and rats were investigated by immunohistochemistry with special emphasis on somatostatin. We observed degenerating somatostatin-immunoreactive cells in the cortices of aged macaques and tree shrews. Somatostatin-immunoreactive senile plaque-like structures were found in areas 6 and 8 and in the nucleus accumbens of macaques, as well as in the nucleus accumbens and the cortex of aged tree shrews, where amyloid accumulations were observed. Somatostatin degenerations may be related to amyloid accumulations and may play roles in impairments of cognitive functions during aging. © 2012 John Wiley & Sons A/S.

  19. Role of high mobility group box-1 and protection of growth hormone and somatostatin in severe acute pancreatitis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Y.F. [Department of Surgery, Huashan Hospital, Fudan University, Shanghai (China); Wu, M. [Department of Surgery, Jinshan Pavilion Forest Hospital, Shanghai (China); Ma, B.J.; Cai, D.A.; Yin, B.B. [Department of Surgery, Huashan Hospital, Fudan University, Shanghai (China)

    2014-09-12

    In this study, we investigated the potential role of high-mobility group box 1 (HMGB1) in severe acute pancreatitis (SAP) and the effects of growth hormone (G) and somatostatin (S) in SAP rats. The rats were randomly divided into 6 groups of 20 each: sham-operated, SAP, SAP+saline, SAP+G, SAP+S and SAP+G+S. Ileum and pancreas tissues of rats in each group were evaluated histologically. HMGB1 mRNA expression was measured by reverse transcription-PCR. Levels of circulating TNF-α, IL-1, IL-6, and endotoxin were also measured. In the SAP group, interstitial congestion and edema, inflammatory cell infiltration, and interstitial hemorrhage occurred in ileum and pancreas tissues. The levels of HMGB1, TNF-α, IL-1, IL-6 and endotoxin were significantly up-regulated in the SAP group compared with those in the sham-operated group, and the 7-day survival rate was 0%. In the SAP+G and SAP+S groups, the inflammatory response of the morphological structures was alleviated, the levels of HMGB1, TNF-α, IL-1, IL-6, and endotoxin were significantly decreased compared with those in the SAP group, and the survival rate was increased. Moreover, in the SAP+G+S group, all histological scores were significantly improved and the survival rate was significantly higher compared with the SAP group. In conclusion, HMGB1 might participate in pancreas and ileum injury in SAP. Growth hormone and somatostatin might play a therapeutic role in the inflammatory response of SAP.

  20. Role of high mobility group box-1 and protection of growth hormone and somatostatin in severe acute pancreatitis

    International Nuclear Information System (INIS)

    Wang, Y.F.; Wu, M.; Ma, B.J.; Cai, D.A.; Yin, B.B.

    2014-01-01

    In this study, we investigated the potential role of high-mobility group box 1 (HMGB1) in severe acute pancreatitis (SAP) and the effects of growth hormone (G) and somatostatin (S) in SAP rats. The rats were randomly divided into 6 groups of 20 each: sham-operated, SAP, SAP+saline, SAP+G, SAP+S and SAP+G+S. Ileum and pancreas tissues of rats in each group were evaluated histologically. HMGB1 mRNA expression was measured by reverse transcription-PCR. Levels of circulating TNF-α, IL-1, IL-6, and endotoxin were also measured. In the SAP group, interstitial congestion and edema, inflammatory cell infiltration, and interstitial hemorrhage occurred in ileum and pancreas tissues. The levels of HMGB1, TNF-α, IL-1, IL-6 and endotoxin were significantly up-regulated in the SAP group compared with those in the sham-operated group, and the 7-day survival rate was 0%. In the SAP+G and SAP+S groups, the inflammatory response of the morphological structures was alleviated, the levels of HMGB1, TNF-α, IL-1, IL-6, and endotoxin were significantly decreased compared with those in the SAP group, and the survival rate was increased. Moreover, in the SAP+G+S group, all histological scores were significantly improved and the survival rate was significantly higher compared with the SAP group. In conclusion, HMGB1 might participate in pancreas and ileum injury in SAP. Growth hormone and somatostatin might play a therapeutic role in the inflammatory response of SAP

  1. Safety, Pharmacokinetics and Dosimetry of a Long-Acting Radiolabeled Somatostatin Analogue 177Lu-DOTA-EB-TATE in Patients with Advanced Metastatic Neuroendocrine Tumors.

    Science.gov (United States)

    Zhang, Jingjing; Wang, Hao; Jacobson Weiss, Orit; Cheng, Yuejuan; Niu, Gang; Li, Fang; Bai, Chunmei; Zhu, Zhaohui; Chen, Xiaoyuan

    2018-04-13

    Radiolabeled somatostatin analogue therapy has become an established treatment method for patients with well to moderately differentiated unresectable or metastatic neuroendocrine tumors (NETs). The most frequently used somatostatin analogues in clinical practice are octreotide and octreotate. However, both peptides showed suboptimal retention within tumors. The aim of this first-in-human study is to explore the safety and dosimetry of a long-acting radiolabeled somatostatin analogue, lutetium-177-1, 4, 7, 10-tetra-azacyclododecane-1, 4, 7, 10-tetraacetic acid-Evans blue-octreotate ( 177 Lu-DOTA-EB-TATE). Methods: Eight patients (6 males and 2 females; age range, 27-61 y) with advanced metastatic neuroendocrine tumors were recruited. Five patients received a single dose 0.35-0.70 GBq (9.5-18.9 mCi) of 177 Lu-DOTA-EB-TATE and underwent serial whole body planar and single-photon emission computed tomography-computed tomography (SPECT-CT) scans at 2, 24, 72, 120 and 168 h after injection. The other 3 patients received intravenous injection of 0.28-0.41 GBq (7.5-11.1 mCi) of 177 Lu-DOTATATE for the same imaging acquisition procedures at 1, 3, 4, 24 and 72 h after injection. The dosimetry was calculated using the OLINDA/EXM 1.1 software. Results: Administration of 177 Lu-DOTA-EB-TATE was well tolerated, with no adverse symptoms being noticed or reported in any of the patients. Compared with 177 Lu-DOTATATE, 177 Lu-DOTA-EB-TATE showed extended circulation in the blood and achieved 7.9-fold increase of tumor dose delivery. The total body effective doses were 0.205 ± 0.161 mSv/MBq for 177 Lu-DOTA-EB-TATE and 0.174 ± 0.072 mSv/MBq for 177 Lu-DOTATATE. Significant dose delivery increases to the kidneys and bone marrow were also observed in patients receiving 177 Lu-DOTA-EB-TATE than those receiving 177 Lu-DOTATATE (3.2 and 18.2-fold, respectively). Conclusion: By introducing an albumin binding moiety, 177 Lu-DOTA-EB-TATE showed remarkably higher uptake and retention in NET

  2. Somatostatin receptor gene therapy combined with targeted therapy with radiolabeled octreotide: a new treatment for liver metastases.

    NARCIS (Netherlands)

    A. Mearadji (Amir); W.A.P. Breeman (Wouter); L.J. Hofland (Leo); R.L. Marquet (Richard); J. Jeekel (Hans); E.P. Krenning (Eric); C.H.J. van Eijck (Casper); P.M. van Koetsveld (Peter)

    2002-01-01

    textabstractOBJECTIVE: To evaluate the effect of peptide receptor radionuclide therapy (PRRT) on somatostatin receptor (SSR)-transfected colon carcinoma cells in a rat liver metastases model.SUMMARY BACKGROUND DATA: Previously the authors have shown highly effective therapy with

  3. Preparation, formulation and quality control of one step kit 99m Tc - EDDA/HYNIC-Tyr3-Octreotide as a peptide radiopharmaceutical for imaging somatostatin receptor positive tumors

    International Nuclear Information System (INIS)

    Gandomkar, M.; Najafi, R.; Sadat-Ebrahimi, E.; Babaei, M.H.

    2004-01-01

    The high expression of somatostatin receptors in many tumours, have made receptor scintigraphy with 11I n-DTPA-Octreotide a widely used procedure in nuclear medicine. Despite its clinical success, some limitation and drawbacks of radiolabelling with 11I n remain, especially those concerned with the cost, availability and physical decay properties of this radionuclide. 99m Tc - EDDA/HYNIC-Tyr 3 -Octreotide was studied as a new agent with the potential to replace octreoscan in somatostatin receptor scintigraphy. This hydrazino nicotinic acid derivatized somatostatin complex contains ethylenediamine N, N diacetic acid as a co-ligand resulting in a high in vitro and in vivo stability. High labeling yields (>90%) were achieved at high specific activities. Characterization via HPLC, biodistribution and receptor binding of the resulting complex are described. The formulation developed enables rapid and simple labeling of 99m Tc - EDDA/HYNIC-TOC in a manner suitable for clinical setting

  4. GLP-1 regulation of glucagon, somatostatin and insulin in naidm patients: evidence of direct inhibition of A - cells by GLP - 1

    International Nuclear Information System (INIS)

    Naveed, A.K.; Khan, F.A.

    2006-01-01

    Glucagon-like peptide-1 (7-36) amide (GLP-1) is released from the gut into the circulation after meals and is the most potent physiological insulinotropic hormone in man. In contrast to presently available therapeutic agents for non-insulin dependent diabetes mellitus (NIDDM), GLP-1 has the advantages of both suppressing glucagon secretion and delaying gastric emptying. We report first study of subcutaneous GLP-1 treatment to determine the optimum dose required to control the NIDDM. Seven patients, with poorly controlled NIDDM were entered in the study who visited at four visits with intervals of 2-4 days and received saline, 40, 100 and 200 nmol subcutaneous GLP-1, immediately after meals. A standerdized test meal was given. A significant hypoglycaemic response (p<0.05) was achieved in patients given 40, 100 and 200 nmol GLP-1. An increase in insulin levels (p<0.05) was observed as compared to control, when 100 and 200 nmol GLP-1 was given. There was no significant difference between insulin and glucose responses when 100 and 200 nmol of GLP-1 were compared with each. The glucagon levels were significant less (p< 0.05) in patients, given 100 and 200 nmol doses as compared to control. Glucagon inhibitory response to GLP-1, when given in doses of 200 nmol was more (p< 0.05) than 100 nmol GLP-1. Somatostatin levels decreased dose dependently by GLP-1 infusions. It is concluded that suppression of glucagon secretion and inhibition of somatostatin corresponded to dose of GLP-1 used. There was no significant difference in glucose and insulin levels between 100 and 200 nmol GLP-1 doses. Therefore, present study has helped in ascertaining the optimum dose for GLP-1 i.e. 100 nmol. Down regulation of GLP-1 receptors on cells occurred at higher dose while, A and D cells inhibition occurred dose dependently. These results revealed that GLP-1 affects A and D cells directly and also through stimulation of cells. These findings will significantly contribute in the possible role

  5. Molecular imaging with 68Ga-SSTR PET/CT and correlation to immunohistochemistry of somatostatin receptors in neuroendocrine tumours

    International Nuclear Information System (INIS)

    Kaemmerer, Daniel; Haugvik, Sven-Petter; Hommann, Merten; Peter, Luisa; Lupp, Amelie; Schulz, Stefan; Saenger, Joerg; Prasad, Vikas; Kulkarni, Harshad; Baum, Richard Paul

    2011-01-01

    Somatostatin receptors (SSTR) are known for an overexpression in gastroenteropancreatic neuroendocrine tumours (GEP-NET). The aim of the present study was to find out if the receptor density predicted by the semi-quantitative parameters generated from the static positron emission tomography (PET/CT) correlated with the in vitro immunohistochemistry using a novel rabbit monoclonal anti-SSTR2A antibody (clone UMB-1) for specific SSTR2A immunohistochemistry and polyclonal antibodies for SSTR1 and 3-5. Overall 14 surgical specimens generated from 34 histologically documented GEP-NET patients were correlated with the preoperative 68 Ga-DOTA-NOC PET/CT. Quantitative assessment of the receptor density was done using the immunoreactive score (IRS) of Remmele and Stegner; the additional 4-point IRS classification for immunohistochemistry and standardized uptake values (SUV max and SUV mean ) were used for PET/CT. The IRS for SSTR2A and SSTR5 correlated highly significant with the SUV max on the PET/CT (p mean (p max on the 68 Ga-DOTA-NOC PET/CT scans is concordant with the affinity profile of 68 Ga-DOTA-NOC to the SSTR subtypes and demonstrates the excellent qualification of somatostatin analogues in the diagnostics of NET. This study correlating somatostatin receptor imaging using 68 Ga-DOTA-NOC PET/CT with immunohistochemically analysed SSTR also underlines the approval of therapy using somatostatin analogues, follow-up imaging as well as radionuclide therapy. (orig.)

  6. Activation of somatostatin 2 receptors in the brain and the periphery induces opposite changes in circulating ghrelin levels: functional implications

    Directory of Open Access Journals (Sweden)

    Andreas eStengel

    2013-01-01

    Full Text Available Somatostatin is an important modulator of neurotransmission in the central nervous system and acts as a potent inhibitor of hormone and exocrine secretion and regulator of cell proliferation in the periphery. These pleiotropic actions occur through interaction with five G-protein coupled somatostatin receptor subtypes (sst1-5 that are widely expressed in the brain and peripheral organs. The characterization of somatostatin’s effects can be investigated by pharmacological or genetic approaches using newly developed selective sst agonists and antagonists and mice lacking specific sst subtypes. Recent evidence points towards a divergent action of somatostatin in the brain and in the periphery to regulate circulating levels of ghrelin, an orexigenic hormone produced by the endocrine X/A-like cells in the gastric mucosa. Somatostatin interacts with the sst2 in the brain to induce an increase in basal ghrelin plasma levels and counteracts the visceral stress-related decrease in circulating ghrelin in rats. By contrast, stimulation of peripheral somatostatin-sst2 signaling results in the inhibition of basal ghrelin release and mediates the postoperative decrease in circulating ghrelin in rats. The peripheral sst2-mediated reduction of plasma ghrelin is likely to involve a paracrine action of D-cell derived somatostatin acting on sst2 bearing X/A-like ghrelin cells in the gastric mucosa. The other member of the somatostatin family, named cortistatin, in addition to binding to sst1-5 also directly interacts with the ghrelin receptor and therefore may simultaneously modulate ghrelin release and actions at target sites bearing ghrelin receptors representing a link between the ghrelin and somatostatin systems.

  7. Physiologic basics and clinical experience with somatostatin-receptor-scintigraphy

    International Nuclear Information System (INIS)

    Henze, E.; Eberhardt, J.U.; Bohuslavizki, K.H.

    1994-01-01

    The introduction of radiolabelled octreotide, an analogon to the receptor binding hormone Somatostatin, has markedly increased the ability to detect structures and tumours carrying somatostatin receptors by nuclear medicine imaging with high sensitivity and specificity. It has been shown that in vitro receptor density and in vivo scintigraphic results correlate well in particular in tumours of neuroendocrine origin of the GI tract such as insulinomas, gastrinomas, glucagonomas, carcionoids, but also in paragangliomas, small cell lung cancer and meningiomas. As receptors were also shown to be present on so called activated leucocytes granulomas, lymphomas and autoimmune disease have been imaged with octreotide successfully. The specific tracer (In-111-DTPA-D-PHE-Octreotide, Octreoscan R ) is rapidly cleared from the blood pool by the kidneys and, partially, via the liver providing a high target to background ratio. Physiologic uptake is usually observed in the pituitary and thyroid glands, in spleen and liver. Optimum tracer accumulation for tumour scintigraphy is seen on the 24-h-images with the best target to background ratios. Additional SPECT-imaging is recommended in particular in the abdominal regions. The sensitivity in imaging the above named tumours ranges from 70 up to 100%. In-111 octreotide imaging is of diagnostic impact both for the primary diagnostic evaluation as well as for detecting or excluding secondary manifestations in known tumour sites. Of specific value is the information on relative receptor density in the tumour to be treated as may be obtained by quantitative In-111 octreotide imaging for decision making whether or not to use cold octreotide (Sandostatin R ) as a receptor blocking drug for therapy as well as for treatment follow-up studies. (author)

  8. Somatostatin receptor scintigraphy in advanced renal cell carcinoma. Results of a phase II-trial of somatostatine analogue therapy in patients with advanced RCC

    International Nuclear Information System (INIS)

    Freudenberg, L.S.; Goerges, R.; Stergar, H.; Bockisch, A.; Gauler, T.; Bauer, S.; Antoch, G.; Schuette, J.

    2008-01-01

    Aims: objective of this prospective study was to evaluate the role of somatostatin receptor scintigraphy (SRS) in advanced renal cell carcinoma (RCC) with respect to potential therapy with somatostatin analogue (SST-A) and to assess the response rate under therapy with SST-A. Patients, methods: 16 patients with documented progression of histologically confirmed advanced RCC were included. Planar whole-body SRS was performed 4, 24 and 48h post i.v. injection of 175-200 MBq 111 In-pentetreoide. 5 and 25 h p.i. SPECT of thorax and abdomen were performed. Documentation of somatostatin receptor expression via SRS in > 50% of known tumour lesions was the criteria for treatment start with SST-A (Sandostatin LAR registered -Depot 30mg i.m. every four weeks). Results: in 9/16 of the patients SRS showed at least one metastasis with moderate (n = 5) or intense (n = 4) tracer uptake. Lesion-based SRS evaluation showed only 12.1% (20/165) of all metastases. Most false-negative lesions were located in the lungs. In too patients, the majority of the known metastases was SRS positive and these patients received SST-A therapy. The first radiographic evaluation after a two-month interval showed progressive disease in both patients. Conclusions: we conclude that SRS is of limited value in staging of advanced RCC. In our patients SST-A did not result in a growth control of RCC. Consequently, the use of SST-A in advanced RCC seems to be no relevant therapeutic option. (orig.)

  9. The development of radioimmunoassay for somatostatin, its use in the measurement of this peptide in tissues and biological fluids, and an assessment of its physiological role in health and disease

    International Nuclear Information System (INIS)

    Pimstone, B.; Sheppard, M.

    1979-06-01

    Somatostatin peptide initially isolated from ovine hypothalamus has inhibitory effect on secretion growth hormone and on other pituitary hormones like TSH, ACTH. The assay sensitivity sensitivity was approximately 6 pg/tube. The authors did not observe any significant crossreactivity with 19 different hormones and biological substances. High concentration of somatostatin was found in central nervous system, but not only in median eminence of hypothalamus but also in other areas including spine cord. High level of somatostatin was also observed in pancreas, gastric antrum and distal colon. The determinations of somatostatin-like in sera of 22 men and 26 women allowed to establish the normal values which are 0.274+-0.009 ng/ml. MCR in normal subjects was 1949+-250 ml/min, in cases with chronic liver disease the values were similar, and in subjects with chronic renal failure highly significant lowering of MCR equal 501+-32.7 ml/min was observed. Tsub(1/2) varied from 1.1 to 3.0 min in normal subjects, in patients with liver diseases was in ranges 1.2 - 4.8 min and in chronic renal failure from 2.6 - 4.9 min

  10. Molecular imaging with {sup 68}Ga-SSTR PET/CT and correlation to immunohistochemistry of somatostatin receptors in neuroendocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Kaemmerer, Daniel; Haugvik, Sven-Petter; Hommann, Merten [Zentralklinik Bad Berka GmbH, Department of General and Visceral Surgery, Bad Berka (Germany); Peter, Luisa; Lupp, Amelie; Schulz, Stefan [University of Jena, Department of Pharmacology and Toxicology, Jena (Germany); Saenger, Joerg [Laboratory of Pathology and Cytology, Bad Berka (Germany); Prasad, Vikas; Kulkarni, Harshad; Baum, Richard Paul [Zentralklinik Bad Berka, Department of Nuclear Medicine and Center for PET, Bad Berka (Germany)

    2011-09-15

    Somatostatin receptors (SSTR) are known for an overexpression in gastroenteropancreatic neuroendocrine tumours (GEP-NET). The aim of the present study was to find out if the receptor density predicted by the semi-quantitative parameters generated from the static positron emission tomography (PET/CT) correlated with the in vitro immunohistochemistry using a novel rabbit monoclonal anti-SSTR2A antibody (clone UMB-1) for specific SSTR2A immunohistochemistry and polyclonal antibodies for SSTR1 and 3-5. Overall 14 surgical specimens generated from 34 histologically documented GEP-NET patients were correlated with the preoperative {sup 68}Ga-DOTA-NOC PET/CT. Quantitative assessment of the receptor density was done using the immunoreactive score (IRS) of Remmele and Stegner; the additional 4-point IRS classification for immunohistochemistry and standardized uptake values (SUV{sub max} and SUV{sub mean}) were used for PET/CT. The IRS for SSTR2A and SSTR5 correlated highly significant with the SUV{sub max} on the PET/CT (p < 0.001; p < 0.05) and the IRS for SSTR2A with the SUV{sub mean} (p < 0.013). The level of SSTR2A score correlated significantly with chromogranin A staining and indirectly to the tumour grading. The highly significant correlation between SSTR2A and SSTR5 and the SUV{sub max} on the {sup 68}Ga-DOTA-NOC PET/CT scans is concordant with the affinity profile of {sup 68}Ga-DOTA-NOC to the SSTR subtypes and demonstrates the excellent qualification of somatostatin analogues in the diagnostics of NET. This study correlating somatostatin receptor imaging using {sup 68}Ga-DOTA-NOC PET/CT with immunohistochemically analysed SSTR also underlines the approval of therapy using somatostatin analogues, follow-up imaging as well as radionuclide therapy. (orig.)

  11. Experience with indium-111 and yttrium-90-labeled somatostatin analogs.

    Science.gov (United States)

    Virgolini, I; Traub, T; Novotny, C; Leimer, M; Füger, B; Li, S R; Patri, P; Pangerl, T; Angelberger, P; Raderer, M; Burggasser, G; Andreae, F; Kurtaran, A; Dudczak, R

    2002-01-01

    The high level expression of somatostatin receptors (SSTR) on various tumor cells has provided the molecular basis for successful use of radiolabeled octreotide / lanreotide analogs as tumor tracers in nuclear medicine. Other (nontumoral) potential indications for SSTR scintigraphy are based on an increased lymphocyte binding at sites of inflammatory or immunologic diseases such as thyroid-associated ophthalmology. The vast majority of human tumors seem to over-express the one or the other of five distinct hSSTR subtype receptors. Whereas neuroendocrine tumors frequently overexpress hSSTR2, intestinal adenocarcinomas seem to overexpress more often hSSTR3 or hSSTR4, or both of these hSSTR. In contrast to In-DTPA-DPhe(1)-octreotide (OctreoScan(R)) which binds to hSSTR2 and 5 with high affinity (Kd 0.1-5 nM), to hSSTR3 with moderate affinity (K(d) 10-100 nM) and does not bind to hSSTR1 and hSSTR4, (111)In / (90)Y-DOTA-lanreotide was found to bind to hSSTR2, 3, 4, and 5 with high affinity, and to hSSTR1 with lower affinity (K(d) 200 nM). Based on its unique hSSTR binding profile, (111)In-DOTA-lanreotide was suggested to be a potential radioligand for tumor diagnosis, and (90)Y-DOTA-lanreotide suitable for receptor-mediated radionuclide therapy. As opposed to (111)In-DTPA-DPhe(1)-octreotide and (111)In-DOTA-DPhe(1)-Tyr(3)-octreotide, discrepancies in the scintigraphic results were seen in about one third of (neuroendocrine) tumor patients concerning both the tumor uptake as well as detection of tumor lesions. On a molecular level, these discrepancies seem to be based on a "higherrdquuo; high-affinity binding of (111)In-DOTA-DPhe(1)-Tyr(3)-octreotide to hSSTR2 (K(d) 0.1-1 nM). Other somatostatin analogs with divergent affinity to the five known hSSTR subtype receptors have also found their way into the clinics, such as (99m)Tc-depreotide (NeoSpect(R); NeoTect(R)). Most of the imaging results are reported for neuroendocrine tumors (octreotide analogs) or nonsmall cell

  12. The potential value of somatostatin receptor scintigraphy in medullary thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Doerr, U.; Bihl, H. (Katharinenhospital, Stuttgart (Germany). Dept. of Nuclear Medicine); Frank-Raue, K.; Raue, F. (Heidelberg Univ. (Germany). Dept. of Internal Medicine); Sautter-Bihl, M.L.; Buhr, H.J. (Staedt. Klinikum, Karlsruhe (Germany). Dept. of Radiooncology and Nuclear Medicine); Guzman, G. (Katherinenhospital, Stuttgart (Germany). Dept. of Nuclear Medicine Inst. de Neurocirugia, Investigationes Cerebrales ' Dr Asenjo' Santiago (Chile). Dept. de Medicina Nuclear)

    1993-06-01

    In a prospective study, ten patients with recurrent medullary thyroid carcinoma (markedly elevated calcitonin levels) were investigated by means of somatostatin receptor scintigraphy (SRS) with [sup 111]In-pentetreotide. Scintigraphically, 30 sites of pathological uptake were found, mostly located in the neck and upper mediastinum. So far, 18 suspected tumour sites underwent histological examination and 14 of them could be verified as metastases of medullary thyroid carcinoma (MTC). The remaining four putative tumour lesions turned out to be false positive scintigraphic findings caused by chronic inflammation and somatostatin receptor positive tumours other than MTC. We conclude that SRS is a promising imaging modality for localization of MTC recurrence and may thus make a contribution to better management of this patient group. (Author).

  13. The potential value of somatostatin receptor scintigraphy in medullary thyroid carcinoma

    International Nuclear Information System (INIS)

    Doerr, U.; Bihl, H.; Frank-Raue, K.; Raue, F.; Sautter-Bihl, M.L.; Buhr, H.J.; Guzman, G.; Inst. de Neurocirugia, Investigationes Cerebrales 'Dr Asenjo' Santiago

    1993-01-01

    In a prospective study, ten patients with recurrent medullary thyroid carcinoma (markedly elevated calcitonin levels) were investigated by means of somatostatin receptor scintigraphy (SRS) with 111 In-pentetreotide. Scintigraphically, 30 sites of pathological uptake were found, mostly located in the neck and upper mediastinum. So far, 18 suspected tumour sites underwent histological examination and 14 of them could be verified as metastases of medullary thyroid carcinoma (MTC). The remaining four putative tumour lesions turned out to be false positive scintigraphic findings caused by chronic inflammation and somatostatin receptor positive tumours other than MTC. We conclude that SRS is a promising imaging modality for localization of MTC recurrence and may thus make a contribution to better management of this patient group. (Author)

  14. Novel Somatostatin Receptor Ligands Therapies for Acromegaly

    Directory of Open Access Journals (Sweden)

    Rosa Maria Paragliola

    2018-03-01

    Full Text Available Surgery is considered the treatment of choice in acromegaly, but patients with persistent disease after surgery or in whom surgery cannot be considered require medical therapy. Somatostatin receptor ligands (SRLs octreotide (OCT, lanreotide, and the more recently approved pasireotide, characterized by a broader receptor ligand binding profile, are considered the mainstay in the medical management of acromegaly. However, in the attempt to offer a more efficacious and better tolerated medical approach, recent research has been aimed to override some limitations related to the use of currently approved drugs and novel SRLs therapies, with potential attractive features, have been proposed. These include both new formulation of older molecules and new molecules. Novel OCT formulations are aimed in particular to improve patients’ compliance and to reduce injection discomfort. They include an investigational ready-to-use subcutaneous depot OCT formulation (CAM2029, delivered via prefilled syringes and oral OCT that uses a “transient permeability enhancer” technology, which allows for OCT oral absorption. Another new delivery system is a long-lasting OCT implant (VP-003, which provide stable doses of OCT throughout a period of several months. Finally, a new SRL DG3173 (somatoprim seems to be more selective for GH secretion, suggesting possible advantages in the presence of hyperglycemia or diabetes. How much these innovations will actually be beneficial to acromegaly patients in real clinical practice remains to be seen.

  15. Synthesis and evaluation of ligand targeting the somatostatin receptor for drug delivery to tumor cell

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So Young; Hong, Young Don; Jung, Sung Hee; Choi, Sun Ju [Radioisotope Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-12-15

    Most of targeted therapies block the action of certain enzymes, proteins, or other molecules involved in the growth and spread of cancer cells to produce its cytotoxic effect. Either small molecule drugs or monoclonal antibodies are mostly used in targeted therapies. Unfortunately, targeted therapy has a certain degree of unwanted side effect like other cytotoxicity inducing chemotherapies. To overcome and to reduce unwanted side effects during a cancer therapy, recently radiopeptide therapies has got the worlds' attraction for the tumor targeting modalities due to its beneficial effect on less side effect compared to cytotoxic chemotherapies. Among radiopeptide therapies, {sup 177}Lu-DOTATATE is a major modality as an effective one invented so far in treating neuroendocrine tumor (NET) and it has been in clinical trials at least one decade. Although it does have rather effective therapeutic effect on NET, it has less effective in rather large solid tumor. There are many ways to improve or increase therapeutic effect of radiopeptide are a finding the potent small molecules to target the tumor site selectively, or a labeling with radioisotope of emitting high energy, or an improving its biological half-life by introducing different moieties to increase lipophilicity. Present study was focus to increase a biological halflife of radio somatostatin which will target the somatostatin receptor by altering the bifunctional chelator (BFCA) by introducing lipophilic moiety to the somatostatin, which would make the labeled peptide stay longer in the tumor site and thus it can intensify the therapeutic effect on tumor cell itself and around tissues.

  16. Ga-68 Somatostatin Receptor PET/CT in von Hippel-Lindau Disease

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jong-Ryool; Min, Jung-Joon [Chonnam National Univ. Hwasun Hospital, Hwasun (Korea, Republic of); Kulkarui, Harshad; Carreras, Cecilia; Schalch, Georg; Baum, Richard P. [Nuclear Medicine and Center for PET/CT, Zentralk Bad Berka, Bad Verka (Germany)

    2012-06-15

    Von Hippel-Lindau (VHL) disease is a dominantly inherited familial cancer syndrome with a variety of benign and malignant tumors such as retinal and central nervous system hemangioblastomas, endolymphatic sac tumors, renalcysts and tumors, pancreatic cysts and tumors, pheochromo-cytomas, and epididymal cystadenomas. Cross-sectional mo-dalities (computed tomography and magnetic resonance imaging) as well as ultrasound play a major role in the initial evaluation and follow-up of the various manifestations of VHL disease. Ga-68-labeled somatostatin receptor analogs already have a significant role in the diagnosis, staging, and therapy management of neuroendocrine neoplasms and neural crest tumors. Herein, we report a case presenting a variety of malignancies in VHL and showing the usefulness of Ga-68 somatostatin receptor PET/CT as a one-stop-shop imaging modality in the management of VHL disease.

  17. Ga-68 Somatostatin Receptor PET/CT in von Hippel-Lindau Disease

    International Nuclear Information System (INIS)

    Oh, Jong-Ryool; Min, Jung-Joon; Kulkarui, Harshad; Carreras, Cecilia; Schalch, Georg; Baum, Richard P.

    2012-01-01

    Von Hippel-Lindau (VHL) disease is a dominantly inherited familial cancer syndrome with a variety of benign and malignant tumors such as retinal and central nervous system hemangioblastomas, endolymphatic sac tumors, renalcysts and tumors, pancreatic cysts and tumors, pheochromo-cytomas, and epididymal cystadenomas. Cross-sectional mo-dalities (computed tomography and magnetic resonance imaging) as well as ultrasound play a major role in the initial evaluation and follow-up of the various manifestations of VHL disease. Ga-68-labeled somatostatin receptor analogs already have a significant role in the diagnosis, staging, and therapy management of neuroendocrine neoplasms and neural crest tumors. Herein, we report a case presenting a variety of malignancies in VHL and showing the usefulness of Ga-68 somatostatin receptor PET/CT as a one-stop-shop imaging modality in the management of VHL disease

  18. Are radiogallium-labelled DOTA-conjugated somatostatin analogues superior to those labelled with other radiometals?

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, P.; Ginj, M.; Zhang, H.; Maecke, H. [University Hospital Basel, Division of Radiological Chemistry, Basel (Switzerland); Waser, B.; Reubi, J.C. [University of Bern, Institute of Pathology, Bern (Switzerland); Baum, R.P. [Zentralklinik Bad Berka, Department of Nuclear Medicine/PETCT-Center, Bad Berka (Germany)

    2007-07-15

    Gallium-68 is a metallic positron emitter with a half-life of 68 min that is ideal for the in vivo use of small molecules, such as [{sup 68}Ga-DOTA,Tyr{sup 3}]octreotide, in the diagnostic imaging of somatostatin receptor-positive tumours. In preclinical studies it has shown a striking superiority over its {sup 111}In-labelled congener. The purpose of this study was to evaluate whether third-generation somatostatin-based, radiogallium-labelled peptides show the same superiority. Peptides were synthesised on solid phase. The receptor affinity was determined by in vitro receptor autoradiography. The internalisation rate was studied in AR4-2J and hsst-HEK-transfected cell lines. The pharmacokinetics was studied in a rat xenograft tumour model, AR4-2J. All peptides showed high affinities on hsst2, with the highest affinity for the Ga{sup III}-complexed peptides. On hsst3 the situation was reversed, with a trend towards lower affinity of the Ga{sup III} peptides. A significantly increased internalisation rate was found in sst2-expressing cells for all {sup 67}Ga-labelled peptides. Internalisation into HEK-sst3 was usually faster for the {sup 111}In-labelled peptides. No internalisation was found into sst5. Biodistribution studies employing [{sup 67}Ga-DOTA,1-Nal{sup 3}]octreotide in comparison to [{sup 111}In-DOTA,1-Nal{sup 3}]octreotide and [{sup 67}Ga-DOTA,Tyr{sup 3}]octreotide showed a significantly higher and receptor-mediated uptake of the two{sup 67}Ga-labelled peptides in the tumour and somatostatin receptor-positive tissues. A patient study illustrated the potential advantage of a broad receptor subtype profile radiopeptide over a high-affinity sst2-selective radiopeptide. This study demonstrates that {sup 67/68}Ga-DOTA-octapeptides show distinctly better preclinical, pharmacological performances than the {sup 111}In-labelled peptides, especially on sst2-expressing cells and the corresponding animal models. They may be excellent candidates for further

  19. Are radiogallium-labelled DOTA-conjugated somatostatin analogues superior to those labelled with other radiometals?

    International Nuclear Information System (INIS)

    Antunes, P.; Ginj, M.; Zhang, H.; Maecke, H.; Waser, B.; Reubi, J.C.; Baum, R.P.

    2007-01-01

    Gallium-68 is a metallic positron emitter with a half-life of 68 min that is ideal for the in vivo use of small molecules, such as [ 68 Ga-DOTA,Tyr 3 ]octreotide, in the diagnostic imaging of somatostatin receptor-positive tumours. In preclinical studies it has shown a striking superiority over its 111 In-labelled congener. The purpose of this study was to evaluate whether third-generation somatostatin-based, radiogallium-labelled peptides show the same superiority. Peptides were synthesised on solid phase. The receptor affinity was determined by in vitro receptor autoradiography. The internalisation rate was studied in AR4-2J and hsst-HEK-transfected cell lines. The pharmacokinetics was studied in a rat xenograft tumour model, AR4-2J. All peptides showed high affinities on hsst2, with the highest affinity for the Ga III -complexed peptides. On hsst3 the situation was reversed, with a trend towards lower affinity of the Ga III peptides. A significantly increased internalisation rate was found in sst2-expressing cells for all 67 Ga-labelled peptides. Internalisation into HEK-sst3 was usually faster for the 111 In-labelled peptides. No internalisation was found into sst5. Biodistribution studies employing [ 67 Ga-DOTA,1-Nal 3 ]octreotide in comparison to [ 111 In-DOTA,1-Nal 3 ]octreotide and [ 67 Ga-DOTA,Tyr 3 ]octreotide showed a significantly higher and receptor-mediated uptake of the two 67 Ga-labelled peptides in the tumour and somatostatin receptor-positive tissues. A patient study illustrated the potential advantage of a broad receptor subtype profile radiopeptide over a high-affinity sst2-selective radiopeptide. This study demonstrates that 67/68 Ga-DOTA-octapeptides show distinctly better preclinical, pharmacological performances than the 111 In-labelled peptides, especially on sst2-expressing cells and the corresponding animal models. They may be excellent candidates for further development for clinical studies. (orig.)

  20. Correlation of Somatostatin Receptor-2 Expression with Gallium-68-DOTA-TATE Uptake in Neuroblastoma Xenograft Models

    OpenAIRE

    Zhang, Libo; Vines, Douglass C.; Scollard, Deborah A.; McKee, Trevor; Komal, Teesha; Ganguly, Milan; Do, Trevor; Wu, Bing; Alexander, Natasha; Vali, Reza; Shammas, Amer; Besanger, Travis; Baruchel, Sylvain

    2017-01-01

    Peptide-receptor imaging and therapy with radiolabeled somatostatin analogs such as 68Ga-DOTA-TATE and 177Lu-DOTA-TATE have become an effective treatment option for SSTR-positive neuroendocrine tumors. The purpose of this study was to evaluate the correlation of somatostatin receptor-2 (SSTR2) expression with 68Ga-DOTA-TATE uptake and 177Lu-DOTA-TATE therapy in neuroblastoma (NB) xenograft models. We demonstrated variable SSTR2 expression profiles in eight NB cell lines. From micro-PET imagin...

  1. Development and preclinical evaluation of radiolabelled somatostatin receptor agonists and αvβ3-integrin antagonists

    International Nuclear Information System (INIS)

    Stoecklin, G.; Wester, H.J.; Haubner, R.; Schottelius, M.

    2002-01-01

    Tumours express specific receptors for peptide ligands. This can be exploited for tumour targeting. New bioactive peptides are available, in particular new somatostatin analogs and RGD-Peptides for targeting the α V β 3 -integrin. The design and optimization of radiolabelled peptides with respect to their receptor affinity, tumour uptake, biodistribution, pharmacokinetics and stability may provide better tracers for tumour imaging and therapy. Based on two basic structures, new radioiodinated and carbohydrated somatostatin analogs and cyclic RGD-peptides were developed and evaluated. (author)

  2. Diet-Induced Growth Is Regulated via Acquired Leptin Resistance and Engages a Pomc-Somatostatin-Growth Hormone Circuit

    Directory of Open Access Journals (Sweden)

    Heiko Löhr

    2018-05-01

    Full Text Available Summary: Anorexigenic pro-opiomelanocortin (Pomc/alpha-melanocyte stimulating hormone (αMSH neurons of the hypothalamic melanocortin system function as key regulators of energy homeostasis, also controlling somatic growth across different species. However, the mechanisms of melanocortin-dependent growth control still remain ill-defined. Here, we reveal a thus-far-unrecognized structural and functional connection between Pomc neurons and the somatotropic hypothalamo-pituitary axis. Excessive feeding of larval zebrafish causes leptin resistance and reduced levels of the hypothalamic satiety mediator pomca. In turn, this leads to reduced activation of hypophysiotropic somatostatin (Sst-neurons that express the melanocortin receptor Mc4r, elevated growth hormone (GH expression in the pituitary, and enhanced somatic growth. Mc4r expression and αMSH responsiveness are conserved in Sst-expressing hypothalamic neurons of mice. Thus, acquired leptin resistance and attenuation of pomca transcription in response to excessive caloric intake may represent an ancient mechanism to promote somatic growth when food resources are plentiful. : The melanocortin system controls energy homeostasis and somatic growth, but the underlying mechanisms are elusive. Löhr et al. identify a functional neural circuit in which Pomc neurons stimulate hypothalamic somatostatin neurons, thereby inhibiting hypophyseal growth hormone production. Excessive feeding and acquired leptin resistance attenuate this pathway, allowing faster somatic growth when food resources are rich. Keywords: Pomc neuron, somatostatin neuron, somatic growth, growth hormone, melanocortin system, high-fat diet, obesity, leptin resistance, zebrafish, mouse

  3. Molecular imaging of neuroendocrine tumors using 68Ga-labeled peptides (Somatostatin receptor PET/CT)

    International Nuclear Information System (INIS)

    Baum, R.P.; Prasad, V.; Hoersch, D.

    2009-01-01

    Receptor PET/CT using 68 Ga-labeled somatostatin analogues (DOTA-NOC, DOTA-TOC or DOTA-TATE) enables the highly sensitive molecular imaging of neuroendocrine tumors (NETs) based on the expression of somatostatin receptors and even the detection of receptor subtypes. Our experience after more than 3000 studies shows that receptor PET/CT has a significantly higher tumor detection rate than conventional scintigraphy (even in SPECT/CT technique), and that tumor lesions can be very accurately localized. By calculating standardized uptake values (SUV) - which are reproducible and investigator-independent - patients can be selected for peptide receptor radiotherapy and also the course after therapy can be controlled. Receptor-PET/CT is the most sensitive imaging modality for the detection of unknown primary tumors (CUP syndrome), which is especially true for the detection of neuroendocrine tumors of the pancreas and small bowel; whole-body staging (''one stop shop'') as well as restaging and selection of patients for peptide receptor radiotherapy can be performed using a patient-friendly procedure (examination finished within one hour) exposing the patient to less radiation than whole-body CT scanning. The 68 Ge/ 68 Ga generator has proved very reliable over the years - even in a hospital environment. The effective costs for 68 Ga labeled somatostatin analogues might be less than for scintigraphic agents, provided a certain number of studies per year are performed. The development of new tumor-specific peptides as well as of other DOTA- or NOTA-coupled radiopharmaceuticals opens a new avenue into the future: finally, the 68 Ga generator could play a similar important role for PET/CT as did the 99m Tc-Generator for conventional gamma camera imaging over the last decades. (orig.)

  4. Novel, potent, and radio-iodinatable somatostatin receptor 1 (sst1) selective analogues.

    Science.gov (United States)

    Erchegyi, Judit; Cescato, Renzo; Grace, Christy Rani R; Waser, Beatrice; Piccand, Véronique; Hoyer, Daniel; Riek, Roland; Rivier, Jean E; Reubi, Jean Claude

    2009-05-14

    The proposed sst(1) pharmacophore (J. Med. Chem. 2005, 48, 523-533) derived from the NMR structures of a family of mono- and dicyclic undecamers was used to design octa-, hepta-, and hexamers with high affinity and selectivity for the somatostatin sst(1) receptor. These compounds were tested for their in vitro binding properties to all five somatostatin (SRIF) receptors using receptor autoradiography; those with high SRIF receptor subtype 1 (sst(1)) affinity and selectivity were shown to be agonists when tested functionally in a luciferase reporter gene assay. Des-AA(1,4-6,10,12,13)-[DTyr(2),DAgl(NMe,2naphthoyl)(8),IAmp(9)]-SRIF-Thr-NH(2) (25) was radio-iodinated ((125)I-25) and specifically labeled sst(1)-expressing cells and tissues. 3D NMR structures were calculated for des-AA(1,4-6,10,12,13)-[DPhe(2),DTrp(8),IAmp(9)]-SRIF-Thr-NH(2) (16), des-AA(1,2,4-6,10,12,13)-[DAgl(NMe,2naphthoyl)(8),IAmp(9)]-SRIF-Thr-NH(2) (23), and des-AA(1,2,4-6,10,12,13)-[DAgl(NMe,2naphthoyl)(8),IAmp(9),Tyr(11)]-SRIF-NH(2) (27) in DMSO. Though the analogues have the sst(1) pharmacophore residues at the previously determined distances from each other, the positioning of the aromatic residues in 16, 23, and 27 is different from that described earlier, suggesting an induced fit mechanism for sst(1) binding of these novel, less constrained sst(1)-selective family members.

  5. Technetium-99m somatostatin analogues: effect of labelling methods and peptide sequence

    International Nuclear Information System (INIS)

    Decristoforo, C.; Mather, S.J.

    1999-01-01

    In this paper the preclinical evaluation of the somatostatin analogue RC160 labelled with technetium-99m using bifunctional chelators (BFCs) based on the hydrazinonicotinamide (HYNIC) and N 3 S system is described and a comparison made with [Tyr 3 ]-octreotide (TOC). Conjugates of both peptides with HYNIC, and of RC160 with benzoyl-MAG 3 and an N 3 S-adipate derivative were prepared and radiolabelling performed at high specific activities using tricine, tricine/nicotinic acid and ethylenediamine-N,N'-diacetic adic (EDDA) as co-ligands for HYNIC conjugates. All conjugates and 99m Tc-labelled peptides showed preserved binding affinity for the somatostatin receptor (IC50, Kd 99m Tc-RC160 derivatives compared with 99m Tc-EDDA/HYNIC-[Tyr 3 ]-octreotide (0.2%-3.5%ID/g vs 9.7%ID/g) and correlated well with the reduced internalisation rate for RC160 derivatives. Our results show that the selection of the labelling approach as well as the right choice of the peptide structure are crucial for labelling peptides with 99m Tc to achieve complexes with favourable biodistribution. Despite the relatively low tumour uptake compared with 99m Tc-EDDA/HYNIC-[Tyr 3 ]-octreotide, 99m Tc-RC160 could play a role in imaging tumours that do not bind octreotide derivatives. (orig.)

  6. Unique functional properties of somatostatin-expressing GABAergic neurons in mouse barrel cortex.

    NARCIS (Netherlands)

    Gentet, L.J.; Kremer, Y.; Taniguchi, H.; Huang, Z.J.; Staiger, J.F.; Petersen, C.C.H.

    2012-01-01

    Neocortical GABAergic neurons have diverse molecular, structural and electrophysiological features, but the functional correlates of this diversity are largely unknown. We found unique membrane potential dynamics of somatostatin-expressing (SOM) neurons in layer 2/3 of the primary somatosensory

  7. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  8. The Inhibitory Effect of Somatostatin Receptor Activation on Bee Venom-Evoked Nociceptive Behavior and pCREB Expression in Rats

    Directory of Open Access Journals (Sweden)

    Li Li

    2014-01-01

    Full Text Available The present study examined nociceptive behaviors and the expression of phosphorylated cAMP response element-binding protein (pCREB in the dorsal horn of the lumbar spinal cord and the dorsal root ganglion (DRG evoked by bee venom (BV. The effect of intraplantar preapplication of the somatostatin analog octreotide on nociceptive behaviors and pCREB expression was also examined. Subcutaneous injection of BV into the rat unilateral hindpaw pad induced significant spontaneous nociceptive behaviors, primary mechanical allodynia, primary thermal hyperalgesia, and mirror-thermal hyperalgesia, as well as an increase in pCREB expression in the lumbar spinal dorsal horn and DRG. Octreotide pretreatment significantly attenuated the BV-induced lifting/licking response and mechanical allodynia. Local injection of octreotide also significantly reduced pCREB expression in the lumbar spinal dorsal horn and DRG. Furthermore, pretreatment with cyclosomatostatin, a somatostatin receptor antagonist, reversed the octreotide-induced inhibition of the lifting/licking response, mechanical allodynia, and the expression of pCREB. These results suggest that BV can induce nociceptive responses and somatostatin receptors are involved in mediating the antinociception, which provides new evidence for peripheral analgesic action of somatostatin in an inflammatory pain state.

  9. 99mTc-EDDA/HYNIC-TOC somatostatin receptor scintigraphy in daily clinical practice.

    Science.gov (United States)

    Chrapko, Beata Ewa; Nocuń, Anna; Gołebiewska, Renata; Stefaniak, Bogusław; Korobowicz, Elzbieta; Czekajska-Chehab, Elzbieta; Sawicki, Marek; Polkowski, Wojciech Piotr

    2010-04-01

    This study aimed to assess the impact of 99mTc-EDDA/HYNIC-TOC (99mTc-TOC) somatostatin receptor scintigraphy (SRS) in clinical practice. One hundred seventeen patients were divided into 6 groups: 1, initial detection and localization of suspected neuroendocrine tumor (NET); 2, tumor staging before therapy; 3, staging of NET of unknown origin, 4, restaging after surgery of primary tumor; 5, diagnosis of solitary pulmonary nodules (SPNs), and 6, follow-up after "cold" somatostatin analogues treatment. In group 1, clinical suspicions were not confirmed in any of the patients; in group 2, most of the primary lesions showed overexpression of somatostatin receptors (SSRT); in group 3, the primary tumor was not identified in any of the patients; in group 4, recurrences were depicted in 7 out of 47 patients; in group 5, only 1 malignant SPN was detected, and in group 6, regression of primary mass and metastases were seen on follow-up SRS in 1 patient. 99mTc-TOC SRS is useful in staging of SSRT-overexpressing tumors of known and unknown primary origin, as well as in restaging after primary tumor surgery. This method is less effective in detecting suspected NET and assessing SPNs. Further investigation is necessary to evaluate the usefulness of SRS in monitoring patients after biological treatment.

  10. Analysis of transmission of novel polymorphisms in the somatostatin receptor 5 (SSTR5) gene in patients with autism

    DEFF Research Database (Denmark)

    Lauritsen, Marlene B; Nyegaard, Mette; Betancur, Catalina

    2003-01-01

    growth hormone response has been reported in some individuals with autism. Moreover, the somatostatinergic system interacts with the dopaminergic system, which has been hypothesized to be involved in the etiology of autism; in particular, somatostatin secretion is regulated by dopamine, and the dopamine......Infantile autism is a pervasive developmental disorder with a strong genetic component. The mode of inheritance appears to be complex and no specific susceptibility genes have yet been identified. Chromosome 16p13.3 may contain a susceptibility gene based on findings from genome scans and reports...... of chromosome abnormalities in individuals with autism. The somatostatin receptor 5 (SSTR5) gene is located on chromosome 16p13.3 and is thus a positional candidate gene for autism. SSTR5 may also be a functional candidate gene for autism because somatostatin inhibits growth hormone secretion, and increased...

  11. Quantum Dot Immunocytochemical Localization of Somatostatin in Somatostatinoma by Widefield Epifluorescence, Super-resolution Light, and Immunoelectron Microscopy

    Science.gov (United States)

    Lai, Ken; Wu, Xiaojuan; Yong, Jim L. C.; Lee, C. Soon

    2012-01-01

    Quantum dot nanocrystal probes (QDs) have been used for detection of somatostatin hormone in secretory granules of somatostatinoma tumor cells by immunofluorescence light microscopy, super-resolution light microscopy, and immunoelectron microscopy. Immunostaining for all modalities was done using sections taken from an epoxy resin-embedded tissue specimen and a similar labeling protocol. This approach allowed assessment of labeling at light microscopy level before examination at super-resolution and electron microscopy level and was a significant aid in interpretation. Etching of ultrathin sections with saturated sodium metaperiodate was a critical step presumably able to retrieve some tissue antigenicity masked by processing in epoxy resin. Immunofluorescence microscopy of QD-immunolabeled sections showed somatostatin hormone localization in cytoplasmic granules. Some variable staining of tumor gland-like structures appeared related to granule maturity and dispersal of granule contents within the tumor cell cytoplasm. Super-resolution light microscopy demonstrated localization of somatostatin within individual secretory granules to be heterogeneous, and this staining pattern was confirmed by immunoelectron microscopy. PMID:22899862

  12. Quantum dot immunocytochemical localization of somatostatin in somatostatinoma by Widefield Epifluorescence, super-resolution light, and immunoelectron microscopy.

    Science.gov (United States)

    Killingsworth, Murray C; Lai, Ken; Wu, Xiaojuan; Yong, Jim L C; Lee, C Soon

    2012-11-01

    Quantum dot nanocrystal probes (QDs) have been used for detection of somatostatin hormone in secretory granules of somatostatinoma tumor cells by immunofluorescence light microscopy, super-resolution light microscopy, and immunoelectron microscopy. Immunostaining for all modalities was done using sections taken from an epoxy resin-embedded tissue specimen and a similar labeling protocol. This approach allowed assessment of labeling at light microscopy level before examination at super-resolution and electron microscopy level and was a significant aid in interpretation. Etching of ultrathin sections with saturated sodium metaperiodate was a critical step presumably able to retrieve some tissue antigenicity masked by processing in epoxy resin. Immunofluorescence microscopy of QD-immunolabeled sections showed somatostatin hormone localization in cytoplasmic granules. Some variable staining of tumor gland-like structures appeared related to granule maturity and dispersal of granule contents within the tumor cell cytoplasm. Super-resolution light microscopy demonstrated localization of somatostatin within individual secretory granules to be heterogeneous, and this staining pattern was confirmed by immunoelectron microscopy.

  13. Union of {sup 99m} Tc-HYNIC-TOC at the somatostatin receptors in cells of pancreas cancer; Union del {sup 99m} Tc-HYNIC-TOC a los receptores de somatostatina en celulas de cancer de pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez C, J. [Facultad de Medicina, UAEM, 50000 Toluca, Estado de Mexico (Mexico); Ramirez I, M.T. [INCMNSZ, Vasco de Quiroga Num. 15, Tlalpan, 14000 Mexico D.F. (Mexico); Ferro F, G.; Pedraza L, M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    The radiation toxic effects have been used in therapy however much 50 years. The absorbed radiation dose can be determined at cellular level using cancerous cell cultures. If the deposited In vitro radiation dose coming from similar activities of several therapeutic radiopharmaceuticals it can compare it will be possible to choose the therapeutic radiopharmaceutical that it offers better dosimetric characteristics for the patient. The objective of this original investigation was to determine the union percentage of the octreotide {sup 99m}Tc-HYNlC-TOC to the somatostatin receivers in cells of cancer pancreas as well as the internalization, externalization and cellular viability. It was used the octapeptide, (octreotide, TOC) labelled with {sup 99m}Tc by means of the HYNIC chelating agent (6-hydrazine pyridine-3-carboxylic acid) and 3 cellular lines of murine pancreas cancer (AR42J), of cancer of human pancreas (CAPAN) and of one negative cellular line for somatostatin receivers (WRL-68). The {sup 99m}Tc-HYNIC-TOC was compared against two negative proofs for somatostatin receivers: the peptide {sup 99m}Tc-UBI and the {sup 99m}TcO{sub 4}. The cellular lines were conserved in the synthetic media Dulbecco-Eagle. After 2, 4 and 24 h of exhibition to the radiation, the cells are picked up and its are determined the viability by count in a Neubauer camera using tripan blue. In the same times it was calculated the union percentage of the radiopharmaceutical to the cells and the internalization (union to the cytoplasm) and the externalization (union to membrane receivers). With those figures it was calculated the absorbed radiation dose at cellular level. Results: At 4 hours the union percentage of the {sup 99m}Tc-HYNlC-TOC to the AR42-J cells was 6.83 times greater than for the WRL-68 control cells of human papilloma, (without receivers of the somatostatin) and for the CAPAN them 4 times greater than for the same cells used as negative control, for the case of the {sup 99m

  14. Union of {sup 99m} Tc-HYNIC-TOC at the somatostatin receptors in cells of pancreas cancer; Union del {sup 99m} Tc-HYNIC-TOC a los receptores de somatostatina en celulas de cancer de pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez C, J [Facultad de Medicina, UAEM, 50000 Toluca, Estado de Mexico (Mexico); Ramirez I, M T [INCMNSZ, Vasco de Quiroga Num. 15, Tlalpan, 14000 Mexico D.F. (Mexico); Ferro F, G; Pedraza L, M [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    The radiation toxic effects have been used in therapy however much 50 years. The absorbed radiation dose can be determined at cellular level using cancerous cell cultures. If the deposited In vitro radiation dose coming from similar activities of several therapeutic radiopharmaceuticals it can compare it will be possible to choose the therapeutic radiopharmaceutical that it offers better dosimetric characteristics for the patient. The objective of this original investigation was to determine the union percentage of the octreotide {sup 99m}Tc-HYNlC-TOC to the somatostatin receivers in cells of cancer pancreas as well as the internalization, externalization and cellular viability. It was used the octapeptide, (octreotide, TOC) labelled with {sup 99m}Tc by means of the HYNIC chelating agent (6-hydrazine pyridine-3-carboxylic acid) and 3 cellular lines of murine pancreas cancer (AR42J), of cancer of human pancreas (CAPAN) and of one negative cellular line for somatostatin receivers (WRL-68). The {sup 99m}Tc-HYNIC-TOC was compared against two negative proofs for somatostatin receivers: the peptide {sup 99m}Tc-UBI and the {sup 99m}TcO{sub 4}. The cellular lines were conserved in the synthetic media Dulbecco-Eagle. After 2, 4 and 24 h of exhibition to the radiation, the cells are picked up and its are determined the viability by count in a Neubauer camera using tripan blue. In the same times it was calculated the union percentage of the radiopharmaceutical to the cells and the internalization (union to the cytoplasm) and the externalization (union to membrane receivers). With those figures it was calculated the absorbed radiation dose at cellular level. Results: At 4 hours the union percentage of the {sup 99m}Tc-HYNlC-TOC to the AR42-J cells was 6.83 times greater than for the WRL-68 control cells of human papilloma, (without receivers of the somatostatin) and for the CAPAN them 4 times greater than for the same cells used as negative control, for the case of the {sup 99m

  15. Glycine-extended gastrin enhances somatostatin release from cultured rabbit fundic D-cells [v1; ref status: indexed, http://f1000r.es/8n

    Directory of Open Access Journals (Sweden)

    Ian LP Beales

    2013-02-01

    Full Text Available The role of the peptide hormone gastrin in stimulating gastric acid secretion is well established. Mature amidated gastrin is processed from larger peptide precursor forms. Increasingly these processing intermediates, such as glycine-extended gastrin (G-Gly and progastrin, have been shown to have biological activities of their own, often separate and complementary to gastrin. Although G-Gly is synthesized and secreted by gastric antral G-cells, the physiological functions of this putative mediator are unclear. Gastrin and cholecystokinin (CCK stimulate the secretion of somatostatin from gastric D-cells as part of the feedback control of gastric acid. In this study the effect of G-Gly and gastrin on the release of somatostatin from rabbit fundic D-cells was examined. D-cells were obtained by collagenase-EDTA digestion and elutriation and cultured for 48 hours. With a 2 hour exposure to the peptides, gastrin but not G-Gly stimulated somatostatin release. Treatment of D-cells for 24 hours with gastrin or G-Gly individually, significantly enhanced subsequent basal as well as CCK- and GLP-1-stimulated somatostatin release. Twenty four hours exposure to gastrin combined with G-Gly synergistically enhanced basal and agonist-stimulated somatostatin release and cellular somatostatin content. Gastrin and G-Gly may be important in the longer term regulation of D-cell function.

  16. Application of single-vial ready-for-use formulation of 111In- or 177Lu-labelled somatostatin analogs.

    Science.gov (United States)

    de Blois, Erik; Chan, Ho Sze; de Zanger, Rory; Konijnenberg, Mark; Breeman, Wouter A P

    2014-02-01

    For the sake of safety it would be desirable to store and transport the ready-for-use liquid formulation (diagnostics and therapeutics) of radiolabelled peptides. The use of ethanol, in combination with a mixture of gentisic- and ascorbic acid, has superior effects on stabilizing radiolabelled somatostatin analogs. As a consequence, (111)In- and (177)Lu-labelled somatostatin analogs can be stored and transported in a single-vial ready-for-use liquid formulation up to 7 days after radiolabelling. © 2013 Published by Elsevier Ltd.

  17. Synthesis of a Fluorescently Labeled 68Ga-DOTA-TOC Analog for Somatostatin Receptor Targeting.

    Science.gov (United States)

    Ghosh, Sukhen C; Hernandez Vargas, Servando; Rodriguez, Melissa; Kossatz, Susanne; Voss, Julie; Carmon, Kendra S; Reiner, Thomas; Schonbrunn, Agnes; Azhdarinia, Ali

    2017-07-13

    Fluorescently labeled imaging agents can identify surgical margins in real-time to help achieve complete resections and minimize the likelihood of local recurrence. However, photon attenuation limits fluorescence-based imaging to superficial lesions or lesions that are a few millimeters beneath the tissue surface. Contrast agents that are dual-labeled with a radionuclide and fluorescent dye can overcome this limitation and combine quantitative, whole-body nuclear imaging with intraoperative fluorescence imaging. Using a multimodality chelation (MMC) scaffold, IRDye 800CW was conjugated to the clinically used somatostatin analog, 68 Ga-DOTA-TOC, to produce the dual-labeled analog, 68 Ga-MMC(IRDye 800CW)-TOC, with high yield and specific activity. In vitro pharmacological assays demonstrated retention of receptor-targeting properties for the dual-labeled compound with robust internalization that was somatostatin receptor (SSTR) 2-mediated. Biodistribution studies in mice identified the kidneys as the primary excretion route for 68 Ga-MMC(IRDye 800CW)-TOC, along with clearance via the reticuloendothelial system. Higher uptake was observed in most tissues compared to 68 Ga-DOTA-TOC but decreased as a function of time. The combination of excellent specificity for SSTR2-expressing cells and suitable biodistribution indicate potential application of 68 Ga-MMC(IRDye 800CW)-TOC for intraoperative detection of SSTR2-expressing tumors.

  18. Somatostatin receptor scintigraphy in sarcoidosis: relation to selected clinical and laboratory markers.

    Science.gov (United States)

    Piotrowski, Wojciech J; Bieńkiewicz, Małgorzata; Frieske, Izabella; Marczak, Jerzy; Antczak, Adam; Górski, Paweł; Kuśmierek, Jacek; Płachcińska, Anna

    2012-01-01

    Discriminating between active and inactive sarcoidosis may be problematic in everyday clinical practice. There are numerous biochemical markers used in the diagnosis and monitoring of sarcoidosis. Somatostatin receptor (SR) scintigraphy with the use of 99mTc-octreotide may be used to estimate disease activity. The aim of the paper was to assess the value of traditional biomarkers (serum angiotensin-converting enzyme [SACE], C-reactive protein, markers of calcium metabolism, bronchoalveolar lavage fluid [BALF] lymphocytes) and a novel biomarker, 8-isoprostane (8-IP) in exhaled breath condensate (EBC), in the assessment of sarcoidosis activity in relation to somatostatin receptor scintigraphy. The study included 32 patients with sarcoidosis. Scintigraphy was performed using somatostatin analogue, 99mTc-HYNIC-TOC; planar and SPECT/CT images were recorded. The study group was divided into a subgroup with positive radiotracer uptake (n = 20) and without a visible uptake (n = 12). 8-IP levels were measured in EBC by an immunoenzymatic assay. RESULTS We observed a significantly higher EBC 8-IP levels in the subgroup with positive uptake compared with those with negative uptake (19.1 ± 19.8 vs. 5.4 ± 3.5 pg/ml, P = 0.02). The levels of SACE and the percentage of BALF lymphocytes were also nonsignificantly elevated. In the group of patients with positive scintigraphy results, a positive correlation was observed between the uptake ratio and SACE (r = 0.44, P = 0.041). The results indicate low value of biochemical markers in the assessment of disease activity. SR scintigraphy may have practical usefulness in the monitoring of sarcoidosis.

  19. Immunohistochemical expression of insulin, glucagon, and somatostatin in pancreatic islets of horses with and without insulin resistance.

    Science.gov (United States)

    Newkirk, Kim M; Ehrensing, Gordon; Odoi, Agricola; Boston, Raymond C; Frank, Nicholas

    2018-02-01

    OBJECTIVE To assess insulin, glucagon, and somatostatin expression within pancreatic islets of horses with and without insulin resistance. ANIMALS 10 insulin-resistant horses and 13 insulin-sensitive horses. PROCEDURES For each horse, food was withheld for at least 10 hours before a blood sample was collected for determination of serum insulin concentration. Horses with a serum insulin concentration horses with a serum insulin concentration > 20 μU/mL underwent a frequently sampled IV glucose tolerance test to determine sensitivity to insulin by minimal model analysis. Horses with a sensitivity to insulin horses were euthanized with a barbiturate overdose, and pancreatic specimens were harvested and immunohistochemically stained for determination of insulin, glucagon, and somatostatin expression in pancreatic islets. Islet hormone expression was compared between insulin-resistant and insulin-sensitive horses. RESULTS Cells expressing insulin, glucagon, and somatostatin made up approximately 62%, 12%, and 7%, respectively, of pancreatic islet cells in insulin-resistant horses and 64%, 18%, and 9%, respectively, of pancreatic islet cells in insulin-sensitive horses. Expression of insulin and somatostatin did not differ between insulin-resistant and insulin-sensitive horses, but the median percentage of glucagon-expressing cells in the islets of insulin-resistant horses was significantly less than that in insulin-sensitive horses. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that, in insulin-resistant horses, insulin secretion was not increased but glucagon production might be downregulated as a compensatory response to hyperinsulinemia.

  20. Tissue-type plasminogen activator in somatostatin cells of rat pancreas and hypothalamus

    DEFF Research Database (Denmark)

    Kristensen, P; Larsson, L I; Danø, K

    1987-01-01

    -PA, and immunoblotting analysis demonstrated one band with a similar electrophoretic mobility. No urokinase-type PA immunoreactivity was found in the rat endocrine pancreas. A granular t-PA immunoreactivity resembling that found in adjacent sections with somatostatin antiserum was found in the median eminence...

  1. CXCL14-like Immunoreactivity Exists in Somatostatin-containing Endocrine Cells, and in the Lamina Propria and Submucosal Somatostatinergic Nervous System of Mouse Alimentary Tract.

    Science.gov (United States)

    Suzuki, Hirohumi; Yamada, Kentaro; Matsuda, Yasuhiro; Onozuka, Minoru; Yamamoto, Toshiharu

    2017-12-26

    In the present study, we investigated the distribution of CXCL14 immunoreactive endocrine cells and neurons in mouse alimentary tract by immunohistochemistry. CXCL14 immunoreactive endocrine cells were found as closed-type cells in the stomach and open-type cells in the small intestine. The immunostaining of these endocrine cells corresponded with that of the somatostatin-containing endocrine cells. Only a few CXCL14 immunoreactive endocrine cells were seen in the large intestine. CXCL14 immunoreactive fibers were observed in the muscular layer from the stomach to the rectum with most abundance in the rectum. Many CXCL14 immunoreactive fibers were observed in the lamina propria and submucosal layer from the duodenum to the rectum with most abundance in the rectum; these fibers corresponded to the somatostatin-containing nerve fibers. Some CXCL14 immunoreactive neuronal somata that were also immuno-positive for somatostatin, were noted in the submucosal layer of the rectum. However, the remaining parts of the alimentary tract presented with almost negligible immunoreactive somata. The co-localization of CXCL14 and somatostatin suggests that CXCL14 contributes to the function of somatostatin, which include the inhibition of other endocrine and exocrine cells and the enteric nervous systems.

  2. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  3. Positron emission tomography study on pancreatic somatostatin receptors in normal and diabetic rats with {sup 68}Ga-DOTA-octreotide: A potential PET tracer for beta cell mass measurement

    Energy Technology Data Exchange (ETDEWEB)

    Sako, Takeo [Division of Bio-function Dynamics Imaging, RIKEN Center for Life Science Technologies, 6-7-3 Minatojima-minamimachi, Chuo-ku, Kobe, Hyogo 650-0047 (Japan); Division of Molecular Imaging, Institute of Biomedical Research and Innovation, 2-2 Minatojima-minamimachi, Chuo-ku, Kobe, Hyogo 650-0047 (Japan); Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Hasegawa, Koki; Nishimura, Mie; Kanayama, Yousuke; Wada, Yasuhiro; Hayashinaka, Emi; Cui, Yilong; Kataoka, Yosky [Division of Bio-function Dynamics Imaging, RIKEN Center for Life Science Technologies, 6-7-3 Minatojima-minamimachi, Chuo-ku, Kobe, Hyogo 650-0047 (Japan); Senda, Michio [Division of Bio-function Dynamics Imaging, RIKEN Center for Life Science Technologies, 6-7-3 Minatojima-minamimachi, Chuo-ku, Kobe, Hyogo 650-0047 (Japan); Division of Molecular Imaging, Institute of Biomedical Research and Innovation, 2-2 Minatojima-minamimachi, Chuo-ku, Kobe, Hyogo 650-0047 (Japan); Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Watanabe, Yasuyoshi, E-mail: yywata@riken.jp [Division of Bio-function Dynamics Imaging, RIKEN Center for Life Science Technologies, 6-7-3 Minatojima-minamimachi, Chuo-ku, Kobe, Hyogo 650-0047 (Japan)

    2013-12-06

    Highlights: •PET images showed high uptake of {sup 68}Ga-DOTA-octreotide in the normal pancreas. •{sup 68}Ga-DOTA-octreotide specifically binds to somatostatin receptors in the pancreas. •The pancreatic uptake of {sup 68}Ga-DOTA-octreotide was decreased in the diabetic rats. •{sup 68}Ga-DOTA-octreotide could be a candidate PET probe to measure the beta cell mass. -- Abstract: Diabetes mellitus (DM) is a metabolic disorder characterized by hyperglycemia, and the loss or dysfunction of pancreatic beta cells has been reported before the appearance of clinical symptoms and hyperglycemia. To evaluate beta cell mass (BCM) for improving the detection and treatment of DM at earlier stages, we focused on somatostatin receptors that are highly expressed in the pancreatic beta cells, and developed a positron emission tomography (PET) probe derived from octreotide, a metabolically stable somatostatin analog. Octreotide was conjugated with 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), a chelating agent, and labeled with {sup 68}Gallium ({sup 68}Ga). After intravenous injection of {sup 68}Ga-DOTA-octreotide, a 90-min emission scan of the abdomen was performed in normal and DM model rats. The PET studies showed that {sup 68}Ga-DOTA-octreotide radioactivity was highly accumulated in the pancreas of normal rats and that the pancreatic accumulation was significantly reduced in the rats administered with an excess amount of unlabeled octreotide or after treatment with streptozotocin, which was used for the chemical induction of DM in rats. These results were in good agreement with the ex vivo biodistribution data. These results indicated that the pancreatic accumulation of {sup 68}Ga-DOTA-octreotide represented specific binding to the somatostatin receptors and reflected BCM. Therefore, PET imaging with {sup 68}Ga-DOTA-octreotide could be a potential tool for evaluating BCM.

  4. Somatostatin receptor 2A expression in choroidal neovascularization secondary to age-related macular degeneration

    NARCIS (Netherlands)

    A.C. Lambooij (Antoinette); R.W.A.M. Kuijpers (Robert); E.G. van Lichtenauer-Kaligis; M. Kliffen (Mike); G.S. Baarsma (Seerp); P.M. van Hagen (Martin); C.M. Mooy (Cornelia)

    2000-01-01

    textabstractPURPOSE: The growth of ocular neovascularization is regulated by a balance between stimulating and inhibiting growth factors. Somatostatin affects angiogenesis by inhibiting the growth hormone-insulin-like growth factor axis and also has a direct

  5. Somatostatin receptor scintigraphy - a case report and review of the literature

    International Nuclear Information System (INIS)

    Yamaga, Lilian Yuri Itaya; Belfer, Aron J.; Segal, Amisa

    1997-01-01

    The authors report a case of carcinoid tumor, diagnosed in a 75-year-old male patient, confirmed by laparotomy and anatomo-pathological study. The patient was examined by somatostatin receptor scintigraphy with In-pentetreotide, and correlation was performed with I-MIBG and CT scan. A review of current literature about this new tracer for detection of carcinoid tumor is presented. (author)

  6. Long-term Primary Medical Therapy with Somatostatin Analogs in Acromegaly

    Directory of Open Access Journals (Sweden)

    Deng-Huang Su

    2006-01-01

    Full Text Available To cure acromegalic patients, transsphenoidal surgery is considered first, especially for microadenoma. However, less than 50% of patients with macroadenoma achieve satisfactory biochemical control. Moreover, surgery may cause hypopituitarism. Medical therapy may offer the prospect of near normalization of growth hormone (GH/insulin-like growth factor-1 levels with substantial tumor shrinkage in a significant number of patients. Here, we report two cases of acromegaly under treatment with somato-statin analogs alone for more than 10 years. Case 1 was a 54-year-old man with a pituitary macro-adenoma. He received 4 years of octreotide treatment followed by 6 years of prolonged-release (PR lanreotide resulting in normal GH level. Case 2 was a 60-year-old woman with a 1.3 cm pituitary tumor. She received 8 years of octreotide treatment followed by 6 years of PR lanreotide resulting in subnormal GH level and gallbladder sludge. She had received bilateral total hip replacement for hip osteoarthritis at the age of 59 years. These cases illustrate that long-term treatment with somatostatin analogs offers an alternative choice in selected acromegalic patients, such as those with pituitary tumor who cannot be cured by surgery, those who have unacceptable anesthetic risk and those who refuse surgery.

  7. Optimized dose distribution of a high dose rate vaginal cylinder

    International Nuclear Information System (INIS)

    Li Zuofeng; Liu, Chihray; Palta, Jatinder R.

    1998-01-01

    Purpose: To present a comparison of optimized dose distributions for a set of high-dose-rate (HDR) vaginal cylinders calculated by a commercial treatment-planning system with benchmark calculations using Monte-Carlo-calculated dosimetry data. Methods and Materials: Optimized dose distributions using both an isotropic and an anisotropic dose calculation model were obtained for a set of HDR vaginal cylinders. Mathematical optimization techniques available in the computer treatment-planning system were used to calculate dwell times and positions. These dose distributions were compared with benchmark calculations with TG43 formalism and using Monte-Carlo-calculated data. The same dwell times and positions were used for a quantitative comparison of dose calculated with three dose models. Results: The isotropic dose calculation model can result in discrepancies as high as 50%. The anisotropic dose calculation model compared better with benchmark calculations. The differences were more significant at the apex of the vaginal cylinder, which is typically used as the prescription point. Conclusion: Dose calculation models available in a computer treatment-planning system must be evaluated carefully to ensure their correct application. It should also be noted that when optimized dose distribution at a distance from the cylinder surface is calculated using an accurate dose calculation model, the vaginal mucosa dose becomes significantly higher, and therefore should be carefully monitored

  8. Progress in high-dose radiation dosimetry

    International Nuclear Information System (INIS)

    Ettinger, K.V.; Nam, J.W.; McLaughlin, W.L.; Chadwick, K.H.

    1981-01-01

    The last decade has witnessed a deluge of new high-dose dosimetry techniques and expanded applications of methods developed earlier. Many of the principal systems are calibrated by means of calorimetry, although production of heat is not always the final radiation effect of interest. Reference systems also include a number of chemical dose meters: ferrous sulphate, ferrous-cupric sulphate, and ceric sulphate acidic aqueous solutions. Requirements for stable and reliable transfer dose meters have led to further developments of several important high-dose systems: amino acids and saccharides analysed by ESR or lyoluminescence, thermoluminescent materials, radiochromic dyes and plastics, ceric-cerous solutions analysed by potentiometry, and ethanol-chlorobenzene solutions analysed by high-frequency oscillometry. A number of other prospective dose meters are also treated in this review. In addition, an IAEA programme of high-dose standardization and intercomparison for industrial radiation processing is described. (author)

  9. Somatostatin analogues labelled with 99mTc

    International Nuclear Information System (INIS)

    Obenaus, Esteban R.; Crudo, Jose L.; Edreira, Martin M.; Castiglia, Silvia G.

    1999-01-01

    Biological and radiochemical studies have been carried out on two labelled somatostatin analogues, the peptide RC-150 and the Tyr 3 -Octreotide. Both analogues have been labelled with 99m Tc using the direct and the indirect method and MAG-3 and HYNIC as chelating agents. By the direct method RC-150 was labelled using sodium ascorbate and dithionite as reducing agents. The radiochemical purity was 70%. By the indirect method, in the case of RC-160 with MAG-3 a radiochemical purity higher than 70% was attained while a purity of 100% was reached in the case of Tyr 3 -Octreotide with HYNIC. The biological distribution of HYNIC-Tyr 3 -Octreotide has been studied in rats. (author)

  10. Growth-hormone and somatostatin effects on [75Se]selenomethionine uptake by the pancreas

    International Nuclear Information System (INIS)

    Atkins, H.L.; Som, P.

    1979-01-01

    The imaging of the pancreas with [ 75 Se]selenomethionine has a low rate of reliability. This study was carried out in order to elucidate some factors that may be important in affecting the degree of uptake of the tracer by the pancreas. Studies were carried out in animals to observe the effects of growth-hormone (GH), somatostatin (SRIF), L-DOPA, and apomorphine administration on the distribution of [ 75 Se]selenomethionine. Intravenously administered GH significantly depressed pancreatic uptake of Se-75 in mice and dogs and depressed the pancreas-to-liver concentration ratio (P/L). The effect of i.p. GH in mice was to decrease the P/L ratio, but the decrease in pancreatic uptake was not statistically significant. There was also a greater effect of GH in dogs than in mice, with pancreatic uptake decreasing from 5.60 +- 2.17% to 1.24 +- 0.96% and the P/L from 4.78 +- 1.85 to 0.97 +- 0.73. L-DOPA and apomorphine produced effects similar to GH in mice. SRIF in small doses had little effect, but in larger doses it enhanced pancreatic uptake, although not affecting P/L. The results indicate that hypothalamic factors may be important in affecting the function of the exocrine pancreas. Both L-DOPA and apomorphine are known to stimulate GH production through hypothalamic-pituitary pathways. In addition to suppressing GH release, SRIF may have direct effects on the exocrine pancreas

  11. Somatostatin in the rat periventricular nucleus: sex differences and effect of gonadal steroids

    NARCIS (Netherlands)

    Vugt, van H.H.; Heijning, van de B.J.M.; Beek, van der E.M.

    2008-01-01

    In the rat, the sexual dimorphism in growth hormone release is driven by sex steroids, and is suggested to result mainly from differences in somatostatin (SOM) release patterns from the median eminence. We studied the effect of gonadal steroids on SOM peptide-containing cells in the periventricular

  12. Preliminary clinical evaluation of Somatostatin Receptor Scintigraphy (SRS) with 99mTc-EDDA/HYNIC-TATE in comparison to 111In-Octreoscan and 131 I MIBG scans

    International Nuclear Information System (INIS)

    Hubalewska, A.; Fross, K.; Staszczak, A.; Huszno, B.; Mikolajczak, R.; Gorska, A.

    2004-01-01

    Full text: Over expression of somatostatin receptors in various neuroendocrine tumours prompted development of somatostatin analogues, which after radioactive labelling, could be used in oncological diagnostics. Somatostatin Receptor Positive Tumour (Spt) imaging with 111In-DTPA-DPhe1- octreotide (111In-Octreoscan) has become a widely used diagnostic procedure in clinical nuclear medicine. However 111In as a radiolabel has several drawbacks, including limited availability, sub optimal gamma energy and high radiation burden to the patient. Technetium (99mTc) labelling of somatostatin analogues is especially attractive due to the ready availability of 99mTc from generators and its well recognised favourable imaging characteristics. HYNIC conjugated Tyr 3 -Octreotate (HYNIC-TATE) prepared in our laboratory in a dry kit form was labelled with technetium-99mTc, with tricine and EDDA used as coligands. Tyr3-octreotate differs from octreotide (OC) by more hydrophilic tyrosine in the third position and the terminal threonine, which replaced threoninol present in OC. In vitro studies using cell lines transfected with somatostatin receptors (SSTR) revealed that octreotate shows 14- 17 times better binding affinity for SSTR type 2 than does OC. It is expected to clear more rapidly from non-target tissues as a result of the carboxylic group at the C-terminal of the peptide. HYNIC has been used as bifunctional chelator in 99mTc-HYNIC-Tyr3-octreotide (TOC) by Maecke and Behe, who reported on its favourable preclinical characteristics when EDDA was used as a co-ligand. These pre-clinical data were confirmed by Decristoforo and Mather and their early clinical studies appeared recently. The new radiopharmaceutical - 99mTc-DDA/HYNICTATE was evaluated in-vitro and in-vivo in an animal model and its potential for SSTR scintigraphy was documented. In the current patient study the diagnostic usefulness of the new radiopharmaceutical was tested for detection of tumours expressing SSTR

  13. Intracranial meningiomas after high-dose irradiation

    International Nuclear Information System (INIS)

    Soffer, D.; Gomori, J.M.; Siegal, T.; Shalit, M.N.

    1989-01-01

    Three patients who presented with intracranial meningiomas 12, 15, and 20 years, respectively, after therapeutic high-dose irradiation of a primary brain tumor are described. Analysis of these cases and similar documented cases suggests that meningiomas after high-dose irradiation constitute a recognizable entity. Patients with such tumors received radiation therapy at a young age (mean age, 9.4 years). After a latent period of 2 to 47 years (mean, 19.8 years) they developed meningiomas at the site of irradiation, at a much younger age than patients with ''spontaneous'' meningiomas. Similar to the situation with meningiomas after low-dose irradiation, a relatively high proportion of meningiomas induced by high-dose irradiation tend to be malignant and biologically aggressive. A very young age at the time of irradiation seems to predispose to the induction of malignant meningiomas, rather than benign tumors. These unusual features provide indirect evidence that high-dose radiation may play a role in the pathogenesis of meningiomas.41 references

  14. Study of somatostatin in simple obesity

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Hafez, M A; El-Ghazaly, S; El-Feky, N A; Sayed, S N [Cairo Univ. (Egypt)

    1990-02-01

    C-peptide, as a marker for pancreatic beta cells function, and somatostatin (SS) in plasma of obese males (n = 15) and a corresponding normal weight control subjects (n = 10) are studied. Fasting plasma SS and serum C-peptide are significantly higher in obese vs lean group. This can be explained by hypertrophy of both D- and B-cells of the pancreatic islets reported by other investigators. Post-prandial plasma SS is insignificantly increased in obese vs the control group whereas the increase in C-peptide levels is significant suggesting unequal response of B- and D-cells to meal in the obese group. It is concluded that circulating SS may play an important role in the development if obesity. Hyperinsulinaemia documented in obesity may be due to hypersecretion of insulin. That may contribute to increased somatomedin-C in obesity. (author).

  15. Study of somatostatin in simple obesity

    International Nuclear Information System (INIS)

    Abdel-Hafez, M.A.; El-Ghazaly, S.; El-Feky, N.A.; Sayed, S.N.

    1990-01-01

    C-peptide, as a marker for pancreatic beta cells function, and somatostatin (SS) in plasma of obese males (n = 15) and a corresponding normal weight control subjects (n = 10) are studied. Fasting plasma SS and serum C-peptide are significantly higher in obese vs lean group. This can be explained by hypertrophy of both D- and B-cells of the pancreatic islets reported by other investigators. Post-prandial plasma SS is insignificantly increased in obese vs the control group whereas the increase in C-peptide levels is significant suggesting unequal response of B- and D-cells to meal in the obese group. It is concluded that circulating SS may play an important role in the development if obesity. Hyperinsulinaemia documented in obesity may be due to hypersecretion of insulin. That may contribute to increased somatomedin-C in obesity. (author)

  16. Somatostatin Negatively Regulates Parasite Burden and Granulomatous Responses in Cysticercosis

    Directory of Open Access Journals (Sweden)

    Mitra Khumbatta

    2014-01-01

    Full Text Available Cysticercosis is an infection of tissues with the larval cysts of the cestode, Taenia  solium. While live parasites elicit little or no inflammation, dying parasites initiate a granulomatous reaction presenting as painful muscle nodules or seizures when cysts are located in the brain. We previously showed in the T. crassiceps murine model of cysticercosis that substance P (SP, a neuropeptide, was detected in early granulomas and was responsible for promoting granuloma formation, while somatostatin (SOM, another neuropeptide and immunomodulatory hormone, was detected in late granulomas; SOM’s contribution to granuloma formation was not examined. In the current studies, we used somatostatin knockout (SOM−/− mice to examine the hypothesis that SOM downmodulates granulomatous inflammation in cysticercosis, thereby promoting parasite growth. Our results demonstrated that parasite burden was reduced 5.9-fold in SOM−/− mice compared to WT mice (P<0.05. This reduction in parasite burden in SOM−/− mice was accompanied by a 95% increase in size of their granulomas (P<0.05, which contained a 1.5-fold increase in levels of IFN-γ and a 26-fold decrease in levels of IL-1β (P<0.05 for both compared to granulomas from WT mice. Thus, SOM regulates both parasite burden and granulomatous inflammation perhaps through modulating granuloma production of IFN-γ and IL-1β.

  17. High-dose irradiation of food

    International Nuclear Information System (INIS)

    Diehl, J.F.

    1999-01-01

    Studies performed on behalf of the International Project on Food Irradiation in the period from 1971 until 1980 resulted in the concluding statement that ''.the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required.'' Since then, licenses for food irradiation have been restricted to this maximum dose in any country applying this technology. Further testing programmes have been carried out investigating the wholesomeness or hazards of high-dose irradiation, but there has been little demand so far by the food industry for licensing of high-dose irradiation, as there is only a small range of products whose irradiation at higher doses offers advantages for given, intended use. These include eg. spices, dried herbs, meat products in flexible pouch packagings for astronauts, or patients with immune deficiencies. (orig./CB) [de

  18. ''Low dose'' and/or ''high dose'' in radiation protection: A need to setting criteria for dose classification

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1997-01-01

    The ''low dose'' and/or ''high dose'' of ionizing radiation are common terms widely used in radiation applications, radiation protection and radiobiology, and natural radiation environment. Reading the title, the papers of this interesting and highly important conference and the related literature, one can simply raise the question; ''What are the levels and/or criteria for defining a low dose or a high dose of ionizing radiation?''. This is due to the fact that the criteria for these terms and for dose levels between these two extreme quantities have not yet been set, so that the terms relatively lower doses or higher doses are usually applied. Therefore, setting criteria for classification of radiation doses in the above mentioned areas seems a vital need. The author while realizing the existing problems to achieve this important task, has made efforts in this paper to justify this need and has proposed some criteria, in particular for the classification of natural radiation areas, based on a system of dose limitation. (author)

  19. Additional lesions detected in therapeutic scans with 177Lu-DOTATATE reflect higher affinity of 177Lu-DOTATATE for somatostatin receptors.

    Science.gov (United States)

    Mirzaei, Siroos; Bastati, Brigitte; Lipp, Rainer W; Knoll, Peter; Zojer, Niklas; Ludwig, Heinz

    2011-01-01

    Peptide receptor-targeted radionuclide therapy (PRRT) of somatostatin receptor (SR)-expressing neuroendocrine tumors (NETs) has become an established therapeutic option in patients with advanced NETs. The aim of this study was to compare the lesion detection rate of (99m)Tc-EDDA/HYNIC-TOC, a newly developed tracer for NET imaging, with (177)Lu-DOTATATE used for PRRT. 8 patients (4 women, 4 men, age range 46-76 years) with histologically proven NETs, who showed high SR loads by (99m)Tc-EDDA/HYNIC-TOC scintigraphy, were treated with (177)Lu-DOTATATE. After treatment, all patients were subjected to whole-body scintigraphy with additional low-dose single-photon emission computed tomography (SPECT-CT) of the chest and abdomen. All patients demonstrated (177)Lu-DOTATATE accumulation in all lesions previously detected by (99m)Tc- EDDA/HYNIC-TOC scintigraphy. Three patients showed additional lesions in the liver and lungs. SPECT-CT after (177)Lu-DOTATATE therapy may be helpful in detecting additional lesions not seen using (99m)Tc-EDDA/HYNIC-TOC. This could reflect the broader affinity of (177)Lu-DOTATATE for SRs compared with (99m)Tc-EDDA/HYNIC-TOC. Copyright © 2011 S. Karger AG, Basel.

  20. Expression of the somatostatin receptor family mRNAs in lung cancer

    International Nuclear Information System (INIS)

    Wang Jing; Wang Liangang; Deng Jinglan; Wu Shengxi

    2000-01-01

    To investigate the characteristics of expression and distribution of 5 subtypes of somatostatin receptors (SSTR1-5) in lung cancer, in situ hybridization was used to examine the expression patterns of SSTR mRNAs in 21 cases of different pathologic types of lung cancer tissues with [α- 35 S]dATP labelled oligonucleotides of the 5 SSTR subtypes as probes. Additionally, Leica Q-500 image analysis processing system was employed for the semi-quantitatively analysis of the hybridization signals. Patterns of SSTR1-5 expression in lung cancer tissues were found as follows. SSTR2 was prominent in small cell lung cancer (SCLC), whereas in non-small cell lung cancer (NSCLC) including the adenous cancer (Ad) and the squamous cancer (Sq), the expression of SSTR1 mRNA was stronger than that of the other 4 types. the expression density of SSTR1-5 in the NSCLC was higher that the SCLC (p < 0.01). The expression patterns and densities of the SSTR subtypes showed heterogeneity in different pathologic types of lung cancer. The expressions of the SSTR mRNAs in both SCLC and NSCLC indicated the positive prospects for somatostatin analog (SSA)-oriented agents in the treatment of both types of the lung cancer

  1. Dose-reduction techniques for high-dose worker groups in nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.; Dionne, B.J.

    1991-03-01

    This report summarizes the main findings of a study of the extent of radiation dose received by special work groups in the nuclear power industry. Work groups which chronically get large doses were investigated, using information provided by the industry. The tasks that give high doses to these work groups were examined and techniques described that were found to be particularly successful in reducing dose. Quantitative information on the extent of radiation doses to various work groups shows that significant numbers of workers in several critical groups receive doses greater than 1 and even 2 rem per year, particularly contract personnel and workers at BWR-type plants. The number of radiation workers whose lifetime dose is greater than their age is much less. Although the techniques presented would go some way in reducing dose, it is likely that a sizeable reduction to the high-dose work groups may require development of new dose-reduction techniques as well as major changes in procedures. 10 refs., 26 tabs

  2. The liver plays an important role in the regulation of somatostatin-14 in the rat

    International Nuclear Information System (INIS)

    Raper, S.E.; Kothary, P.C.; Kokudo, N.; DelValle, J.; Eckhauser, F.E.

    1991-01-01

    Since little is known about the in vivo disposition of circulating somatostatin-14 (SRIF-14), we examined hepatic processing of SRIF-14 in the rat. Three minutes after the intraportal injection of iodine 125 ( 125 I)-labeled SRIF-14, 16.0 +/- 2.0% of the injected dose is localized to the liver. In the presence of unlabeled SRIF-14, hepatic uptake can be decreased by 68%. Five minutes after the intraportal injection of 125 I-SRIF-14, 9.5 +/- 1.4% of the tracer is localized to the liver, more than any other organ tested. Serial collections of bile reveal peak radioactivity at between 10 and 20 minutes. Simultaneous administration of unlabeled SRIF-14 decreases biliary radioactivity by 40%. HPLC analysis of radioactive bile reveals a chromatographic profile similar to that of intact SRIF and is 73% immunoprecipitable by an anti-SRIF antibody. Pretreatment with chloroquine, a lysosomal enzyme inhibitor, does not significantly decrease biliary radioactivity. We conclude that the data are consistent with saturable hepatic uptake and predominantly nonlysosomal transcellular transport

  3. Performance of thermoluminescent materials for high dose dosimetry

    International Nuclear Information System (INIS)

    Texeira, Maria I.; Cecatti, Sonia G.P.; Caldas, Linda V.E.

    2008-01-01

    Cases involving high-doses of ionizing radiation are becoming increasingly common.The objective of this work was to characterize thermoluminescent materials for the dosimetry of workers exposed to high doses. Samples of TLD-200, TLD-400 and TLD-800 pellets from Thermo Electron Corporation were studied in gamma high-doses. Dose-response curves were obtained for doses between 100 mGy and 100 Gy. The reproducibility, the lower detection limits and dose-response curves were obtained for all three materials. The different kinds of detectors show usefulness for dosimetry of workers exposed accidentally to high doses. (author)

  4. Effect of subcutaneous injection of a long-acting analogue of somatostatin (SMS 201-995) on plasma thyroid-stimulating hormone in normal human subjects

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, S.; Tanaka, K.; Kumagae, M.; Takeda, F.; Morio, K.; Kogure, M.; Hasegawa, M.; Horiuchi, T.; Watabe, T.; Miyabe, S.

    1988-01-01

    SMS 201-995 (SMS), a synthetic analogue of somatostatin (SRIF) has been shown to be effective in the treatment of the hypersecretion of hormones such as in acromegaly. However, little is known about the effects of SMS on the secretion of thyroid-stimulating hormone (TSH) in normal subjects. In this study, plasma TSH was determined with a highly sensitive immunoradiometric assay, in addition to the concentration of SMS in plasma and urine with a radioimmunoassay, following subcutaneous injection of 25, 50, 100 ..mu..g of SMS or a placebo to normal male subjects, at 0900 h after an overnight fast. The plasma concentrations of SMS were dose-responsive and the peak levels were 1.61 +/- 0.09, 4.91 +/- 0.30 and 8.52 +/- 1.18 ng/ml, which were observed at 30, 15 and 45 min after the injection of 25, 50, and 100 ..mu..g of SMS, respectively. Mean plasma disappearance half-time of SMS was estimated to be 110 +/- 3 min. Plasma TSH was suppressed in a dose dependent manner and the suppression lasted for at least 8 hours. At 8 hours after the injection of 25, 50, and 100 ..mu..g of SMS, the plasma TSH levels were 43.8 +/- 19.4, 33.9 +/- 9.4 and 24.9 +/- 3.2%, respectively, of the basal values.

  5. Breast cancer imaging using radiolabelled somatostatin analogues

    International Nuclear Information System (INIS)

    Dalm, Simone U.; Melis, Marleen; Emmering, Jasper; Kwekkeboom, Dik J.; Jong, Marion de

    2016-01-01

    Imaging and therapy using radiolabelled somatostatin analogues are methods successfully used in patients with somatostatin receptor (SSTR)-expressing neuroendocrine tumours. Since these techniques were first introduced, many improvements have been made. SSTR expression has also been reported on breast cancer (BC). Currently mammography, magnetic resonance imaging and ultrasound are the most frequent methods used for BC imaging. Since SSTR expression on BC was demonstrated, clinical studies examining the feasibility of visualizing primary BC using SSTR radioligands have been performed. However, to date SSTR-mediated nuclear imaging is not used clinically in BC patients. The aim of this review is to assess whether recent improvements made within nuclear medicine may enable SSTR-mediated imaging to play a role in BC management. For this we critically analysed results of past studies and discussed the potential of the improvements made within nuclear medicine on SSTR-mediated nuclear imaging of BC. Seven databases were searched for publications on BC imaging with SSTR radioligands. The papers found were analysed by 3 individual observers to identify whether the studies met the pre-set inclusion criteria defined as studies in which nuclear imaging using radiolabelled SST analogues was performed in patients with breast lesions. Twenty-four papers were selected for this review including studies on SSTR-mediated nuclear imaging in BC, neuroendocrine BC and other breast lesions. The analysed studies were heterogeneous with respect to the imaging method, imaging protocol, patient groups and the radiolabelled SST analogues used. Despite the fact that the analysed studies were heterogeneous, sensitivity for primary BC ranged from 36–100%. In a subset of the studies LN lesions were visualized, but sensitivity was lower compared to that for primary tumours. A part of the studies included benign lesions and specificity ranged from 22–100%. Furthermore, false negatives and

  6. Fiber optics in high dose radiation fields

    International Nuclear Information System (INIS)

    Partin, J.K.

    1985-01-01

    A review of the behavior of state-of-the-art optical fiber waveguides in high dose (greater than or equal to 10 5 rad), steady state radiation fields is presented. The influence on radiation-induced transmission loss due to experimental parameters such as dose rate, total dose, irradiation history, temperature, wavelength, and light intensity, for future work in high dose environments are given

  7. New octreotide derivatives for in vivo targeting of somatostatin receptor-positive tumors for Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Maecke, H.R.; Smith-Jones, P.; Maina, T.; Stolz, B.; Albert, R.; Bruns, C.; Reist, H.

    1993-01-01

    Two new modifications of the somatostatin analog octreotide, designed to hold the gallium isotopes 67 Ga and 68 Ga (DFO-SMS) and 99m Tc (PnAO-SMS) have been synthesized and evaluated in vitro and in vivo in tumor bearing rats. DFO-SMS can be labeled with 67 Ga 3+ and 68 Ga 3+ with high specific activity within less than 30 minutes in a ''cold kit'' type formulation. The labeled conjugate is stable under physiologgical conditions. Moreover the binding affinity to somatostatin receptors on rat brain cortex membranes was shown to be retained. In vivo fast tumor localization was demonstrated and the pharmacokinetics proved to be favourable as the main excretion route was via the kidneys. First PET studies with [ 68 Ga]-DFO-SMS showed a rapid accumulation in the tumor and a residence half-life at the tumor site of about 6 hours. PnAO-SMS can be labeled with 99m Tc with high radiochemical purity. In vivo the radiotracer accumulates well in the tumor but due to its high lipohilicity, its main excretion route is via the hepatobiliary system. (orig.)

  8. Radiophotoluminescence light scope for high-dose dosimetry

    International Nuclear Information System (INIS)

    Sato, Fuminobu; Zushi, Naoki; Sakiyama, Tomoki; Kato, Yushi; Murata, Isao; Shimizu, Kikuo; Yamamoto, Takayoshi; Iida, Toshiyuki

    2015-01-01

    A radiophotoluminescence (RPL) light scope is a remote-sensing technique for measuring in situ the radiation dose in an RPL detector placed at a distance. The RPL light scope is mainly composed of an ultraviolet (UV) pulse laser, telescopic lenses, a photomultiplier tube, and camera modules. In a performance test, some RPL detectors were placed at distances up to 30 m and were illuminated with a pulsed UV laser beam. The photoluminescence responses of the RPL detectors were analyzed using this scope. Their radiation doses were determined from the amplitude of the given component of the photoluminescence responses. The RPL readout could be repeated without fading, and its amplitude exhibited good linearity at a dose ranging from 0.1 to 60 Gy. Furthermore, a two-dimensional distribution of radiation dose was obtained by laser scanning on an RPL detector. It was confirmed that the RPL light scope was a useful remote-sensing tool for high-dose dosimetry. - Highlights: • A radiophotoluminescence (RPL) light scope was developed for high-dose dosimetry. • The RPL light scope has high sensitivity and accuracy in high-dose dosimetry. • Two-dimensional radiation dose distribution was obtained by the RPL light scope.

  9. Positron emission tomography study on pancreatic somatostatin receptors in normal and diabetic rats with 68Ga-DOTA-octreotide: a potential PET tracer for beta cell mass measurement.

    Science.gov (United States)

    Sako, Takeo; Hasegawa, Koki; Nishimura, Mie; Kanayama, Yousuke; Wada, Yasuhiro; Hayashinaka, Emi; Cui, Yilong; Kataoka, Yosky; Senda, Michio; Watanabe, Yasuyoshi

    2013-12-06

    Diabetes mellitus (DM) is a metabolic disorder characterized by hyperglycemia, and the loss or dysfunction of pancreatic beta cells has been reported before the appearance of clinical symptoms and hyperglycemia. To evaluate beta cell mass (BCM) for improving the detection and treatment of DM at earlier stages, we focused on somatostatin receptors that are highly expressed in the pancreatic beta cells, and developed a positron emission tomography (PET) probe derived from octreotide, a metabolically stable somatostatin analog. Octreotide was conjugated with 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), a chelating agent, and labeled with (68)Gallium ((68)Ga). After intravenous injection of (68)Ga-DOTA-octreotide, a 90-min emission scan of the abdomen was performed in normal and DM model rats. The PET studies showed that (68)Ga-DOTA-octreotide radioactivity was highly accumulated in the pancreas of normal rats and that the pancreatic accumulation was significantly reduced in the rats administered with an excess amount of unlabeled octreotide or after treatment with streptozotocin, which was used for the chemical induction of DM in rats. These results were in good agreement with the ex vivo biodistribution data. These results indicated that the pancreatic accumulation of (68)Ga-DOTA-octreotide represented specific binding to the somatostatin receptors and reflected BCM. Therefore, PET imaging with (68)Ga-DOTA-octreotide could be a potential tool for evaluating BCM. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. High-dose dosimetry using natural silicate minerals

    International Nuclear Information System (INIS)

    Carmo, Lucas S. do; Mendes, Leticia; Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina; Barbosa, Renata F.

    2015-01-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  11. High-dose dosimetry using natural silicate minerals

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do; Mendes, Leticia, E-mail: isatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina, E-mail: lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear; Barbosa, Renata F., E-mail: profcelta@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Santos, SP (Brazil). Departamento de Ciencias do Mar

    2015-07-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  12. Transcriptional and Functional Characterization of the G Protein-Coupled Receptor Repertoire of Gastric Somatostatin Cells

    DEFF Research Database (Denmark)

    Egerod, Kristoffer L; Engelstoft, Maja S; Lund, Mari L

    2015-01-01

    In the stomach, somatostatin (SST) acts as a general paracrine negative regulator of exocrine secretion of gastric acid and pepsinogen and endocrine secretion of gastrin, ghrelin, and histamine. Using reporter mice expressing red fluorescent protein (RFP) under control of the SST promotor, we hav...

  13. Development of 99mTc labelled somatostatin analogues and evaluation of their radiochemical and biological behaviour

    International Nuclear Information System (INIS)

    Gano, L.; Patricio, L.

    2001-01-01

    Conjugates of two somatostatin analogues, octreotide and RC-160, with HYNIC were synthesized, characterized and purified by reverse phase HPLC. Radiolabelling of the conjugates with 99m Tc was achieved using tricine as co-ligand. High labelling efficiencies were obtained and 99m Tc peptides with high radiochemical purity were found when analysed both by ITLC and HPLC. In vitro stability of 99m Tc-peptides in human serum and towards cysteine challenge was determined by Cellogel electrophoresis and HPLC after ultrafiltration of serum solution through a 20 kDa cut off membrane. Biodistribution studies were performed in healthy mice at 5 and 30 minutes and 1, 2, 4 and 24 h post-injection. Urine and blood samples were collected at sacrifice time. Samples of urine and ultrafiltrate murine serum were analysed by electrophoresis and reverse phase HPLC in order to get some information about radiocompounds metabolism. Biological distribution of 99m Tc octreotide was also assayed in mice pre-treated with an excess of unlabelled peptide. From our results we conclude that this labelling method led to stable 99m Tc complexes both in vitro and in vivo when high specific activities (37-72 GBq/μmole) were used. Biodistribution studies of both 99m Tc-peptides indicated a radioactivity distribution profile with significant differences especially in the liver uptake that is higher for 99m Tc RC-160. However, a rapid blood clearance was obtained for both radiolabelled peptides, and the urine analysis indicated that 99m Tc peptide is mostly excreted as the initial complex. Pre-treatment with unlabelled peptide did not affect renal excretion of 99m TOC but pancreas and intestine radioactive uptake was significantly lower, indicating saturation of somatostatin receptors and selective uptake. (author)

  14. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  15. Studies on mRNA expression of the somatostatin receptor family in lung cancer

    International Nuclear Information System (INIS)

    Wang Jing; Deng Jinglan; Wu Shengxi; Qiao Hongqing

    2000-01-01

    Objective: To investigate the characteristics of expression and distribution of 5 subtypes of somatostatin receptors (SSTR1∼5) in lung cancer. Methods: With [α- 35 S]dATP labelled oligonucleotides of the 5 SSTR subtypes as probes, using in situ hybridization, patterns of mRNA expression were detected in lung cancer tissue sections of 21 cases which fell in varied pathologic types. Additionally, Leica Q-500 image analyzing device was employed to semi-quantitatively analyze density of the expression. Results: Patterns of SSTR1∼5 expression in lung cancer were as follows: SSTR2 expression was dominant in small cell lung cancer (SCLC) while in non-small cell lung cancer (NSCLC) such as adenous and squamous, SSTR1 expression was stronger than that of the other 4 subtypes, In density of SSTR1∼5 expression in lung cancer, NSCLC was higher than SCLC (P<0.01). Conclusions: even though patterns and density of expression of SSTR subtypes in the lung cancer showed heterogeneity in different histopathologic types, as in SCLC and in NSCLC. Therefore, it has positive prospects for somatostatin analog-oriented agents to be used in treatment of both types of the lung cancers

  16. High dose gamma-ray standard

    International Nuclear Information System (INIS)

    Macrin, R.; Moraru, R.

    1999-01-01

    The high gamma-ray doses produced in a gamma irradiator are used, mainly, for radiation processing, i.e. sterilization of medical products, processing of food, modifications of polymers, irradiation of electronic devices, a.s.o. The used absorbed doses depend on the application and cover the range 10 Gy to 100 MGy. The regulations in our country require that the response of the dosimetry systems, used for the irradiation of food and medical products, be calibrated and traceable to the national standards. In order to be sure that the products receive the desired absorbed dose, appropriate dosimetric measurements must be performed, including the calibration of the dosemeters and their traceability to the national standards. The high dose gamma-ray measurements are predominantly based on the use of reference radiochemical dosemeters. Among them the ferrous sulfate can be used as reference dosemeter for low doses (up to 400 Gy) but due to its characteristics it deserves to be considered a standard dosemeter and to be used for transferring the conventional absorbed dose to other chemical dosemeters used for absorbed doses up to 100 MGy. The study of the ferrous sulfate dosemeter consisted in preparing many batches of solution by different operators in quality assurance conditions and in determining for all batches the linearity, the relative intrinsic error, the repeatability and the reproducibility. The principal results are the following: the linear regression coefficient: 0.999, the relative intrinsic error: max.6 %, the repeatability (for P* = 95 %): max.3 %, the reproducibility (P* = 95%): max.5 %. (authors)

  17. Effects of the single and combined treatment with dopamine agonist, somatostatin analog and mTOR inhibitors in a human lung carcinoid cell line: an in vitro study.

    Science.gov (United States)

    Pivonello, Claudia; Rousaki, Panagoula; Negri, Mariarosaria; Sarnataro, Maddalena; Napolitano, Maria; Marino, Federica Zito; Patalano, Roberta; De Martino, Maria Cristina; Sciammarella, Concetta; Faggiano, Antongiulio; Rocco, Gaetano; Franco, Renato; Kaltsas, Gregory A; Colao, Annamaria; Pivonello, Rosario

    2017-06-01

    Somatostatin analogues and mTOR inhibitors have been used as medical therapy in lung carcinoids with variable results. No data are available on dopamine agonists as treatment for lung carcinoids. The main aim of the current study was to evaluate the effect of the combined treatment of somatostatin analogue octreotide and the dopamine agonist cabergoline with mTOR inhibitors in an in vitro model of typical lung carcinoids: the NCI-H727 cell line. In NCI-H727 cell line, reverse transcriptase-quantitative polymerase chain reaction and immunofluorescence were assessed to characterize the expression of the somatostatin receptor 2 and 5, dopamine receptor 2 and mTOR pathway components. Fifteen typical lung carcinoids tissue samples have been used for somatostatin receptor 2, dopamine receptor 2, and the main mTOR pathway component p70S6K expression and localization by immunohistochemistry. Cell viability, fluorescence-activated cell sorting analysis and western blot have been assessed to test the pharmacological effects of octreotide, cabergoline and mTOR inhibitors, and to evaluate the activation of specific cell signaling pathways in NCI-H727 cell line. NCI-H727 cell line expressed somatostatin receptor 2, somatostatin receptor 5 and dopamine receptor 2 and all mTOR pathway components at messenger and protein levels. Somatostatin receptor 2, dopamine receptor 2, and p70S6K (non phosphorylated and phosphorylated) proteins were expressed in most typical lung carcinoids tissue samples. Octreotide and cabergoline did not reduce cell viability as single agents but, when combined with mTOR inhibitors, they potentiate mTOR inhibitors effect after long-term exposure, reducing Akt and ERK phosphorylation, mTOR escape mechanisms, and increasing the expression DNA-damage-inducible transcript 4, an mTOR suppressor. In conclusion, the single use of octreotide and cabergoline is not sufficient to block cell viability but the combined approach of these agents with mTOR inhibitors

  18. Estimation of the transit dose component in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Garcia Romero, A.; Millan Cebrian, E.; Lozano Flores, F.J.; Lope Lope, R.; Canellas Anoz, M.

    2001-01-01

    Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author) [es

  19. ELDRS Characterization for a Very High Dose Mission

    Science.gov (United States)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee

    2010-01-01

    Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

  20. Age-related changes in Serum Growth Hormone, Insulin-like Growth Factor-1 and Somatostatin in System Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Malemud Charles J

    2004-10-01

    Full Text Available Abstract Background Systemic lupus erythematosus is an age- and gender-associated autoimmune disorder. Previous studies suggested that defects in the hypothalamic/pituitary axis contributed to systemic lupus erythematosus disease progression which could also involve growth hormone, insulin-like growth factor-1 and somatostatin function. This study was designed to compare basal serum growth hormone, insulin-like growth factor-1 and somatostatin levels in female systemic lupus erythematosus patients to a group of normal female subjects. Methods Basal serum growth hormone, insulin-like growth factor-1 and somatostatin levels were measured by standard radioimmunoassay. Results Serum growth hormone levels failed to correlate with age (r2 = 3.03 in the entire group of normal subjects (i.e. 20 – 80 years. In contrast, serum insulin-like growth factor-1 levels were inversely correlated with age (adjusted r2 = 0.092. Of note, serum growth hormone was positively correlated with age (adjusted r2 = 0.269 in the 20 – 46 year range which overlapped with the age range of patients in the systemic lupus erythematosus group. In that regard, serum growth hormone levels were not significantly higher compared to either the entire group of normal subjects (20 – 80 yrs or to normal subjects age-matched to the systemic lupus erythematosus patients. Serum insulin-like growth factor-1 levels were significantly elevated (p 55 yrs systemic lupus erythematosus patients. Conclusions These results indicated that systemic lupus erythematosus was not characterized by a modulation of the growth hormone/insulin-like growth factor-1 paracrine axis when serum samples from systemic lupus erythematosus patients were compared to age- matched normal female subjects. These results in systemic lupus erythematosus differ from those previously reported in other musculoskeletal disorders such as rheumatoid arthritis, osteoarthritis, fibromyalgia, diffuse idiopathic skeletal

  1. Ultrastructural autoradiographic localization of somatostatin-28 in the rat pituitary gland

    International Nuclear Information System (INIS)

    Morel, G.; Leroux, P.; Pelletier, G.

    1985-01-01

    To identify the anterior pituitary cell type(s) containing somatostatin-28 (SS-28)-binding sites and to study the internalization processes of this peptide by the target cells, autoradiography was performed on rat anterior pituitaries removed at specific intervals (2-60 min) after iv injection of the [ 125 I]iodo-SS-28 agonist [Leu8,D-Trp22,Tyr25]SS-28 into intact, adrenalectomized, or castrated male rats. At the light microscopic level, the silver grains were found in 75% of cells. Concomitant injection of an excess of unlabeled peptide prevented the binding of label, verifying the specificity of binding. No specific labeling could be detected in the adrenocorticotrophs of adrenalectomized rats or gonadotrophs (castration cells) of castrated rats. At the electron microscopic level, three cell types (somatotrophs, thyrotrophs, and mammotrophs) appear to contain radiolabeled SS-28. The time-course study in somatotrophs of intact animals showed that 2 min after injection, most silver grains were associated with the plasma membrane. Five to 15 min after injection, label was found over both the plasma membrane and cytoplasmic organelles, especially the Golgi apparatus, lysosomes, and secretory granules. At the longest time interval (60 min), labeling was mostly associated with the cytoplasmic organelles. These results indicate that SS-28-binding sites are present only in those cell types in which somatostatin is known to regulate secretory functions. The present data also show that a rapid internalization of the radiolabeled peptide occurs

  2. Effect of somatostatin on repair of ionizing radiation-induced DNA damage in pituitary adenoma cells GH3

    Czech Academy of Sciences Publication Activity Database

    Řezáčová, M.; Čáp, J.; Vokurková, D.; Lukášová, Emilie; Vávrová, J.; Cerman, J.; Mašín, V.; Mazánková, N.

    2008-01-01

    Roč. 57, č. 2 (2008), s. 225-235 ISSN 0862-8408 Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : acromegaly * somatostatin * ionizing radiation Subject RIV: BO - Biophysics Impact factor: 1.653, year: 2008

  3. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  4. Pharmacokinetically guided dosing of (high-dose) chemotherapeutic agents

    NARCIS (Netherlands)

    Attema-de Jonge, M.E. (Milly Ellen)

    2004-01-01

    Due to variation in drug distribution, metabolism and elimination processes between patients, systemic exposure to chemotherapeutic agents may be highly variable from patient to patient after administration of similar doses. This pharmacokinetic variability may explain in part the large variability

  5. Budget impact of somatostatin analogs as treatment for metastatic gastroenteropancreatic neuroendocrine tumors in US hospitals

    Directory of Open Access Journals (Sweden)

    Ortendahl JD

    2017-08-01

    Full Text Available Jesse D Ortendahl,1 Sonia J Pulgar,2 Beloo Mirakhur,3 David Cox,3 Tanya GK Bentley,1 Alexandria T Phan4 1Health Economics, Partnership for Health, LLC, Beverly Hills, CA, USA; 2Health Economics and Outcomes Research, Ipsen Biopharmaceuticals, Basking Ridge, NJ, USA; 3Medical Affairs, Oncology, Ipsen Biopharmaceuticals, Basking Ridge, NJ, USA; 4GI Medical Oncology, University of New Mexico Comprehensive Cancer Center, Albuquerque, NM, USA Objective: With the introduction of new therapies, hospitals have to plan spending limited resources in a cost-effective manner. To assist in identifying the optimal treatment for patients with locally advanced or metastatic gastroenteropancreatic neuroendocrine tumors, budget impact modeling was used to estimate the financial implications of adoption and diffusion of somatostatin analogs (SSAs. Patients and methods: A hypothetical cohort of 500 gastroenteropancreatic neuroendocrine tumor patients was assessed in an economic model, with the proportion with metastatic disease treated with an SSA estimated using published data. Drug acquisition, preparation, and administration costs were based on national pricing databases and published literature. Octreotide dosing was based on published estimates of real-world data, whereas for lanreotide, real-world dosing was unavailable and we therefore used the highest indicated dosing. Alternative scenarios reflecting the proportion of patients receiving lanreotide or octreotide were considered to estimate the incremental budget impact to the hospital. Results: In the base case, 313 of the initial 500 gastroenteropancreatic neuroendocrine tumor patients were treated with an SSA. The model-predicted per-patient cost was US$83,473 for lanreotide and US$89,673 for octreotide. With a hypothetical increase in lanreotide utilization from 5% to 30% of this population, the annual model-projected hospital costs decreased by US$488,615. When varying the inputs in one-way sensitivity

  6. Proghrelin-derived peptides influence the secretion of insulin, glucagon, pancreatic polypeptide and somatostatin: a study on isolated islets from mouse and rat pancreas

    DEFF Research Database (Denmark)

    Qader, S.S.; Hakanson, R.; Lundquist, I.

    2008-01-01

    ghrelin, and to the 23-amino acid peptide obestatin, claimed to be a physiological opponent of acyl ghrelin. This study examines the effects of the proghrelin products, alone and in combinations, on the secretion of insulin, glucagon, pancreatic polypeptide (PP) and somatostatin from isolated islets...... times higher concentration than acyl ghrelin (corresponding to the ratio of the two peptides in circulation), desacyl ghrelin abolished the effects of acyl ghrelin but not those of obestatin. Acyl ghrelin and obestatin affected the secretion of glucagon, PP and somatostatin at physiologically relevant...

  7. Study on the changes of serum levels of polypeptide growth factors (EGF, TGF-α) and related hormones (gastrin, somatostatin) in patients with peptic ulcer

    International Nuclear Information System (INIS)

    Cao Jianfan; Ma Yunbao; Zhang Xiaoyi

    2005-01-01

    Objective: To study the possible roles of EGF, TGF-α, gastrin and somatostatin in the pathogenesis of peptic ulcer by measuring the changes of serum levels of those four parameters in the patients with peptic ulcer. Methods: Serum levels of epidermal growth factor (EGF), transforming growth factor-α (TGF-α), gastrin (Gas) and somatostatin (SS) were measured with RIA in 30 patients with gastric ulcer, 32 patients with duodenal ulcer and 30 controls. Results: Serum levels of gastrin and EGF were significantly higher in the patients with peptic ulcer than those in the controls (both P 0.05). However, serum TGF-α levels were significantly lower in the ulcer patients than those in the controls (P<0.01). Conclusion: Changes of serum levels of gastrin, EGF and TGF-α were quite significant in the ulcer patients and determining of which might be of clinical meanings. Determination of somatostatin changes seemed to be of less importance. (authors)

  8. Honey Bee Allatostatins Target Galanin/Somatostatin-Like Receptors and Modulate Learning: A Conserved Function?

    Directory of Open Access Journals (Sweden)

    Elodie Urlacher

    Full Text Available Sequencing of the honeybee genome revealed many neuropeptides and putative neuropeptide receptors, yet functional characterization of these peptidic systems is scarce. In this study, we focus on allatostatins, which were first identified as inhibitors of juvenile hormone synthesis, but whose role in the adult honey bee (Apis mellifera brain remains to be determined. We characterize the bee allatostatin system, represented by two families: allatostatin A (Apime-ASTA and its receptor (Apime-ASTA-R; and C-type allatostatins (Apime-ASTC and Apime-ASTCC and their common receptor (Apime-ASTC-R. Apime-ASTA-R and Apime-ASTC-R are the receptors in bees most closely related to vertebrate galanin and somatostatin receptors, respectively. We examine the functional properties of the two honeybee receptors and show that they are transcriptionally expressed in the adult brain, including in brain centers known to be important for learning and memory processes. Thus we investigated the effects of exogenously applied allatostatins on appetitive olfactory learning in the bee. Our results show that allatostatins modulate learning in this insect, and provide important insights into the evolution of somatostatin/allatostatin signaling.

  9. Evaluation of 64Cu-labeled DOTA-D-Phe1-Tyr3-octreotide (64Cu-DOTA-TOC) for imaging somatostatin receptor-expressing tumors

    International Nuclear Information System (INIS)

    Hanaoka, Hirofumi; Tominaga, Hideyuki; Yamada, Keiich

    2009-01-01

    In-111 ( 111 In)-labeled octreotide has been clinically used for imaging somatostatin receptor-positive tumors, and radiolabeled octreotide analogs for positron emission tomography (PET) have been developed. Cu-64 ( 64 Cu; half-life, 12.7 h) is an attractive radionuclide for PET imaging and is produced with high specific activity using a small biomedical cyclotron. The aim of this study is to produce and fundamentally examine a 64 Cu-labeled octreotide analog, 64 Cu-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-D-Phe 1 -Tyr 3 -octreotide ( 64 Cu-DOTA-TOC). 64 Cu produced using a biomedical cyclotron was reacted with DOTA-TOC for 30 min at 45 deg C. The stability of 64 Cu-DOTA-TOC was evaluated in vitro (incubated with serum) and in vivo (blood collected after administration) by high performance liquid chromatography (HPLC) analysis. Biodistribution studies were performed in normal mice by administration of mixed solution of 64 Cu-DOTA-TOC and 111 In-DOTA-TOC and somatostatin receptor-positive U87MG tumor-bearing mice by administration of 64 Cu-DOTA-TOC or 64 Cu-1,4,8,11-tetraazacyclotetradecane-1,4,8,11-tetraacetic acid-octreotide ( 64 Cu-TETA-OC). The tumor was imaged using 64 Cu-DOTA-TOC, 64 Cu-TETA-OC, and fluorodeoxyglucose (FDG) with an animal PET scanner. 64 Cu-DOTA-TOC can be produced in amounts sufficient for clinical study with high radiochemical yield. 64 Cu-DOTA-TOC was stable in vitro, but time-dependent transchelation to protein was observed after injection into mice. In biodistribution studies, the radioactivity of 64 Cu was higher than that of 111 In in all organs except kidney. In tumor-bearing mice, 64 Cu-DOTA-TOC showed a high accumulation in the tumor, and the tumor-to-blood ratio reached as high as 8.81±1.17 at 6 h after administration. 64 Cu-DOTA-TOC showed significantly higher accumulation in the tumor than 64 Cu-TETA-OC. 64 Cu-DOTA-TOC PET showed a very clear image of the tumor, which was comparable to that of 18 F-FDG PET and

  10. The somatostatin receptor-targeted radiotherapeutic [90Y-DOTA-dPhe1,Tyr3]octreotide (90Y-SMT 487) eradicates experimental rat pancreatic CA 20948 tumours

    International Nuclear Information System (INIS)

    Stolz, B.; Weckbecker, G.; Smith-Jones, P.M.; Albert, R.; Raulf, F.; Bruns, C.

    1998-01-01

    Somatostatin receptor-expressing tumours are potential targets for therapy with radiolabelled somatostatin analogues. We have synthesized a number of such analogues in the past and identified [DOTA-dPhe 1 , Tyr 3 ]octreotide (SMT 487) as the most promising candidate molecule because of its advantageous properties in cellular and in vivo tumour models. In the current paper we describe the radiotherapeutic effect of yttrium-90 labelled SMT 487 in Lewis rats bearing the somatostatin receptor-positive rat pancreatic tumour CA 20948. SMT 487 binds with nanomolar affinity to both the human and the rat somatostatin receptor subtype 2 (sst 2 ) (human sst 2 IC 50 =0.9 nM, rat sst 2 IC 50 =0.5 nM). In vivo, 90 Y-SMT 487 distributed rapidly to the sst 2 expressing CA 20948 rat pancreatic tumour, with a tumour-to-blood ratio of 49.15 at 24 h post injection. A single intravenous administration of 10 mCi/kg 90 Y-SMT 487 resulted in a complete remission of the tumours in five out of seven CA 20948 tumour-bearing Lewis rats. No regrowth of the tumours occurred 8 months post injection. Control animals that were treated with 30 μg/kg of unlabelled SMT 487 had to be sacrificed 10 days post injection due to excessive growth or necrotic areas on the tumour surface. Upon re-inoculation of tumour cells into those rats that had shown complete remission, the tumours disappeared after 3-4 weeks of moderate growth without any further treatment. The present study shows for the first time the curative potential of 90 Y-SMT 487-based radiotherapy for somatostatin receptor-expressing tumours. Clinical phase I studies with yttrium-labelled SMT 487 have started in September 1997. (orig.)

  11. “In-house” preparation of 99mTc-EDDA/HYNIC-TOC, a specific targeting agent for somatostatin receptor scintigraphy

    Directory of Open Access Journals (Sweden)

    Sonja Kuzmanovska

    2012-01-01

    Full Text Available The use of radiolabeled peptide ligands as diagnostics and therapeutics in nuclear oncology has increased recently. One of the most frequently used radiopharmaceutical is 99mTc-EDDA/HYNIC-TOC, a somatostatin analog with affinity for certain types of somatostatin receptors, overexpressed in tumors of neuroendocrine origin. The radiopharmaceutical is not readily available; therefore we introduced its “in house” preparation within project activities supported by the International Atomic Energy Agency (IAEA. We optimized the radiolabeling protocol, prepared a small batch of frozen kits, performed ITLC quality control and animal biodistribution during the preclinical evaluation procedures. The co-ligand exchange labeling procedure was carried out at 100°C during 10 min, resulting in radiochemical purity >90%. The biodistribution scintigrams in normal Wistar rats showed rapid blood clearance after 15 min and predominant kidney accumulation after 4 h, in accordance with the data reported by other authors. Storage stability of the formulated small batch frozen kit (-20°C was evaluated within 6 months, with radiolabeling yield ranging between 94,3% and 96,9%. We conclude that frozen kit can be a safe alternative to the freeze-dried for small batch in house production, and after the satisfactory preclinical evaluation, the “in house” prepared 99mTc-EDDA/ HYNIC-TOC can be introduced in clinical practice as specific targeting agent for somatostatin receptor scintigraphy.

  12. Physiological and immunological changes following exposure to low versus high-dose ionizing irradiation; comparative analysis with dose rate and cumulative dose

    International Nuclear Information System (INIS)

    Heesun, Kim; Heewon, Jang; Soungyeon, Song; Shinhye, Oh; Cukcheul, Shin; Meeseon, Jeong; Chasoon, Kim; Kwnaghee, Yang; Seonyoung, Nam; Jiyoung, Kim; Youngwoo, Jin; Changyoung, Cha

    2008-01-01

    Full text: While high-dose of ionizing radiation is generally harmful and causes damage to living organisms some reports suggest low-dose of radiation may not be as damaging as previously thought. Despite increasing evidence regarding the protective effect of low-dose radiation, no studies have directly compared the exact dose-response pattern by high- and low-dose of radiation exposed at high-and low-dose rate. This study aims to explore the cellular and molecular changes in mice exposed to low- and high-dose of radiation exposed at low- and high-dose rate. When C57BL/6 mice (Female, 6 weeks) were exposed at high-dose rate, 0.8 Gy/min, no significant change on the level of WBC, RBC, or platelets was observed up to total dose of 0.5 Gy. However, 2 Gy of radiation caused dramatic reduction in the level of white blood cells (WBC) and platelets. This reduction was accompanied by increased DNA damage in hematopoietic environments. The reduction of WBC was mainly due to the reduction in the number of CD4+ T cells and CD19+ B cells. CD8+ T cells and NK cells appeared to be relatively resistant to high-dose of radiation. This change was also accompanied by the reduction of T- and B- progenitor cells in the bone marrow. In contrast, no significant changes of the number of CD4+ T, CD8+ T, NK, and B cells were observed in the spleen of mice exposed at low-dose-rate (0.7 m Gy/h or 3.95 mGy/h) for up to 2 Gy, suggesting that low-dose radiation does not alter cellular distribution in the spleen. Nevertheless, mice exposed to low-dose radiation exhibited elevation of VEGF, MCP-1, IL-4, Leptin, IL-3, and Tpo in the peripheral blood and slight increases in MIP-2, RANTES, and IL-2 in the spleen. This suggests that chronic γ-radiation can stimulate immune function without causing damage to the immune components of the body. Taken together, these data indicate hormesis of low-dose radiation, which could be attributed to the stimulation of immune function. Dose rate rather than total

  13. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  14. Braquiterapia de alta taxa de dose no Brasil High-dose rate brachytherapy in Brazil

    Directory of Open Access Journals (Sweden)

    Sérgio Carlos Barros Esteves

    2004-10-01

    Full Text Available A braquiterapia de alta taxa de dose foi introduzida em nosso meio em janeiro de 1991. Desde então, houve uma mudança significativa na abordagem das neoplasias malignas em relação às vantagens do novo método, e também resolução da demanda reprimida de braquiterapia para as neoplasias ginecológicas. Nos primeiros dez anos de atividade, o Brasil tratou, em 31 serviços, 26.436 pacientes com braquiterapia, sendo mais de 50% das pacientes portadoras de neoplasias do colo uterino. Este estudo mostra o número e o perfil de pacientes tratados com esse método e a sua distribuição no território nacional, deixando explícito o benefício da braquiterapia de alta taxa de dose para o Brasil.High-dose rate brachytherapy was first introduced in Brazil in January 1991. Significant changes in the management of malignant neoplasms were observed since utilization of high-dose rate brachytherapy. The high number of gynecological patients awaiting for brachytherapy also decreased during this period. In the first ten years 26,436 patients were treated with high-dose rate brachytherapy. More than 50% of these patients presented neoplasms of the uterine cervix. In this study we present the number and profile of the patients treated with high-dose rate brachytherapy as well as the distribution of these patients in the Brazilian territory, proving the benefit of the use of high-dose rate brachytherapy in Brazil.

  15. Long-term effects of cholinergic basal forebrain lesions on neuropeptide Y and somatostatin immunoreactivity in rat neocortex

    NARCIS (Netherlands)

    Gaykema, R.P.A.; Compaan, J.C.; Nyakas, C.; Horvath, E.; Luiten, P.G.M.

    1989-01-01

    The effect of cholinergic basal forebrain lesions on immunoreactivity to somatostatin (SOM-i) and neuropeptide-Y (NPY-i) was investigated in the rat parietal cortex, 16-18 months after multiple bilateral ibotenic acid injections in the nucleus basalis complex. As a result of the lesion, the

  16. Evaluation of (64)Cu-labeled DOTA-D-Phe(1)-Tyr (3)-octreotide ((64)Cu-DOTA-TOC) for imaging somatostatin receptor-expressing tumors.

    Science.gov (United States)

    Hanaoka, Hirofumi; Tominaga, Hideyuki; Yamada, Keiich; Paudyal, Pramila; Iida, Yasuhiko; Watanabe, Shigeki; Paudyal, Bishnuhari; Higuchi, Tetsuya; Oriuchi, Noboru; Endo, Keigo

    2009-08-01

    In-111 ((111)In)-labeled octreotide has been clinically used for imaging somatostatin receptor-positive tumors, and radiolabeled octreotide analogs for positron emission tomography (PET) have been developed. Cu-64 ((64)Cu; half-life, 12.7 h) is an attractive radionuclide for PET imaging and is produced with high specific activity using a small biomedical cyclotron. The aim of this study is to produce and fundamentally examine a (64)Cu-labeled octreotide analog, (64)Cu-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-D: -Phe(1)-Tyr(3)-octreotide ((64)Cu-DOTA-TOC). (64)Cu produced using a biomedical cyclotron was reacted with DOTA-TOC for 30 min at 45 degrees C. The stability of (64)Cu-DOTA-TOC was evaluated in vitro (incubated with serum) and in vivo (blood collected after administration) by HPLC analysis. Biodistribution studies were performed in normal mice by administration of mixed solution of (64)Cu-DOTA-TOC and (111)In-DOTA-TOC and somatostatin receptor-positive U87MG tumor-bearing mice by administration of (64)Cu-DOTA-TOC or (64)Cu-1,4,8,11-tetraazacyclotetradecane-1,4,8,11-tetraacetic acid-octreotide ((64)Cu-TETA-OC). The tumor was imaged using (64)Cu-DOTA-TOC, (64)Cu-TETA-OC, and FDG with an animal PET scanner. (64)Cu-DOTA-TOC can be produced in amounts sufficient for clinical study with high radiochemical yield. (64)Cu-DOTA-TOC was stable in vitro, but time-dependent transchelation to protein was observed after injection into mice. In biodistribution studies, the radioactivity of (64)Cu was higher than that of (111)In in all organs except kidney. In tumor-bearing mice, (64)Cu-DOTA-TOC showed a high accumulation in the tumor, and the tumor-to-blood ratio reached as high as 8.81 +/- 1.17 at 6 h after administration. (64)Cu-DOTA-TOC showed significantly higher accumulation in the tumor than (64)Cu-TETA-OC. (64)Cu-DOTA-TOC PET showed a very clear image of the tumor, which was comparable to that of (18)F-FDG PET and very similar to that of (64)Cu

  17. Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC in patients with medullary thyroid carcinoma.

    Science.gov (United States)

    Czepczyński, Rafał; Parisella, Maria Gemma; Kosowicz, Jerzy; Mikołajczak, Renata; Ziemnicka, Katarzyna; Gryczyńska, Maria; Sowiński, Jerzy; Signore, Alberto

    2007-10-01

    Several new somatostatin analogues have been developed for the diagnosis and therapy of different tumours. Since somatostatin receptors are often over-expressed in medullary thyroid carcinoma (MTC), the aim of our study was to evaluate the utility of scintigraphy with the somatostatin analogue (99m)Tc-EDDA/HYNIC-TOC in MTC in comparison with other diagnostic techniques. Forty-five patients with MTC, aged 14-83 years, were investigated. Scintigraphy using (99m)Tc-EDDA/HYNIC-TOC (Tektrotyd) was performed 2 and 4 h post injection of 740 MBq (20 mCi) of the tracer. Other imaging techniques were also applied and analysed in individual cases (ultrasonography, computed tomography, (99m)Tc(V)-DMSA, (131)I-MIBG, (99m)Tc-MDP, (111)In-DTPA-octreotide and (18)F-FDG-PET) and compared with (99m)Tc-EDDA/HYNIC-TOC. In group 1 (eight patients before thyroidectomy), uptake of the tracer was found in the primary tumours. In group 2 (six patients with remission), a false positive result was found in one patient; in the remaining five patients, no pathological foci were visualised. In group 3 (31 patients with post-surgical hypercalcitoninaemia), scintigraphy was true positive in 23 patients (74.2%): uptake in the thyroid bed was found in five patients, in the lymph nodes in 18 and in bone metastases in four. Using (99m)Tc-EDDA/HYNIC-TOC scintigraphy, the overall sensitivity was 79.5%, specificity 83.3%, accuracy 80.0%, positive predictive value 96.9% and negative predictive value 38.5%. (99m)Tc-EDDA/HYNIC-TOC is clinically useful for scintigraphy in the follow-up of patients with MTC. It can be used in clinical practice for preoperative evaluation, for localisation of local recurrence or distant metastases and particularly for therapy decision making.

  18. Tumor-associated macrophages in glioblastoma multiforme-a suitable target for somatostatin receptor-based imaging and therapy?

    Directory of Open Access Journals (Sweden)

    Constantin Lapa

    Full Text Available Glioblastoma multiforme (GBM is the most common primary brain tumor in adults. Tumor-associated macrophages (TAM have been shown to promote malignant growth and to correlate with poor prognosis. [1,4,7,10-tetraazacyclododecane-NN',N″,N'″-tetraacetic acid]-d-Phe1,Tyr3-octreotate (DOTATATE labeled with Gallium-68 selectively binds to somatostatin receptor 2A (SSTR2A which is specifically expressed and up-regulated in activated macrophages. On the other hand, the role of SSTR2A expression on the cell surface of glioma cells has not been fully elucidated yet. The aim of this study was to non-invasively assess SSTR2A expression of both glioma cells as well as macrophages in GBM.15 samples of patient-derived GBM were stained immunohistochemically for macrophage infiltration (CD68, proliferative activity (Ki67 as well as expression of SSTR2A. Anti-CD45 staining was performed to distinguish between resident microglia and tumor-infiltrating macrophages. In a subcohort, positron emission tomography (PET imaging using 68Ga-DOTATATE was performed and the semiquantitatively evaluated tracer uptake was compared to the results of immunohistochemistry.The amount of microglia/macrophages ranged from 50% in the tumor samples with the vast majority being resident microglial cells. A strong SSTR2A immunostaining was observed in endothelial cells of proliferating vessels, in neurons and neuropile. Only faint immunostaining was identified on isolated microglial and tumor cells. Somatostatin receptor imaging revealed areas of increased tracer accumulation in every patient. However, retention of the tracer did not correlate with immunohistochemical staining patterns.SSTR2A seems not to be overexpressed in GBM samples tested, neither on the cell surface of resident microglia or infiltrating macrophages, nor on the surface of tumor cells. These data suggest that somatostatin receptor directed imaging and treatment strategies are less promising in GBM.

  19. Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC in patients with medullary thyroid carcinoma

    International Nuclear Information System (INIS)

    Czepczynski, Rafal; Kosowicz, Jerzy; Ziemnicka, Katarzyna; Gryczynska, Maria; Sowinski, Jerzy; Parisella, Maria G.; Mikolajczak, Renata; Signore, Alberto

    2007-01-01

    Several new somatostatin analogues have been developed for the diagnosis and therapy of different tumours. Since somatostatin receptors are often over-expressed in medullary thyroid carcinoma (MTC), the aim of our study was to evaluate the utility of scintigraphy with the somatostatin analogue 99m Tc-EDDA/HYNIC-TOC in MTC in comparison with other diagnostic techniques. Forty-five patients with MTC, aged 14-83 years, were investigated. Scintigraphy using 99m Tc-EDDA/HYNIC-TOC (Tektrotyd) was performed 2 and 4 h post injection of 740 MBq (20 mCi) of the tracer. Other imaging techniques were also applied and analysed in individual cases (ultrasonography, computed tomography, 99m Tc(V)-DMSA, 131 I-MIBG, 99m Tc-MDP, 111 In-DTPA-octreotide and 18 F-FDG-PET) and compared with 99m Tc-EDDA/HYNIC-TOC. In group 1 (eight patients before thyroidectomy), uptake of the tracer was found in the primary tumours. In group 2 (six patients with remission), a false positive result was found in one patient; in the remaining five patients, no pathological foci were visualised. In group 3 (31 patients with post-surgical hypercalcitoninaemia), scintigraphy was true positive in 23 patients (74.2%): uptake in the thyroid bed was found in five patients, in the lymph nodes in 18 and in bone metastases in four. Using 99m Tc-EDDA/HYNIC-TOC scintigraphy, the overall sensitivity was 79.5%, specificity 83.3%, accuracy 80.0%, positive predictive value 96.9% and negative predictive value 38.5%. 99m Tc-EDDA/HYNIC-TOC is clinically useful for scintigraphy in the follow-up of patients with MTC. It can be used in clinical practice for preoperative evaluation, for localisation of local recurrence or distant metastases and particularly for therapy decision making. (orig.)

  20. Somatostatin receptor 1 and 5 double knockout mice mimic neurochemical changes of Huntington's disease transgenic mice.

    Directory of Open Access Journals (Sweden)

    Padmesh S Rajput

    Full Text Available Selective degeneration of medium spiny neurons and preservation of medium sized aspiny interneurons in striatum has been implicated in excitotoxicity and pathophysiology of Huntington's disease (HD. However, the molecular mechanism for the selective sparing of medium sized aspiny neurons and vulnerability of projection neurons is still elusive. The pathological characteristic of HD is an extensive reduction of the striatal mass, affecting caudate putamen. Somatostatin (SST positive neurons are selectively spared in HD and Quinolinic acid/N-methyl-D-aspartic acid induced excitotoxicity, mimic the model of HD. SST plays neuroprotective role in excitotoxicity and the biological effects of SST are mediated by five somatostatin receptor subtypes (SSTR1-5.To delineate subtype selective biological responses we have here investigated changes in SSTR1 and 5 double knockout mice brain and compared with HD transgenic mouse model (R6/2. Our study revealed significant loss of dopamine and cAMP regulated phosphoprotein of 32 kDa (DARPP-32 and comparable changes in SST, N-methyl-D-aspartic acid receptors subtypes, calbindin and brain nitric oxide synthase expression as well as in key signaling proteins including calpain, phospho-extracellular-signal-regulated kinases1/2, synapsin-IIa, protein kinase C-α and calcineurin in SSTR1/5(-/- and R6/2 mice. Conversely, the expression of somatostatin receptor subtypes, enkephalin and phosphatidylinositol 3-kinases were strain specific. SSTR1/5 appears to be important in regulating NMDARs, DARPP-32 and signaling molecules in similar fashion as seen in HD transgenic mice.This is the first comprehensive description of disease related changes upon ablation of G- protein coupled receptor gene. Our results indicate that SST and SSTRs might play an important role in regulation of neurodegeneration and targeting this pathway can provide a novel insight in understanding the pathophysiology of Huntington's disease.

  1. Characterization of somatostatin receptors and associated signaling pathways in pancreas of R6/2 transgenic mice.

    Science.gov (United States)

    Somvanshi, Rishi K; Jhajj, Amrit; Heer, Michael; Kumar, Ujendra

    2018-02-01

    The present study describes the status of somatostatin receptors (SSTRs) and their colocalization with insulin (β), glucagon (α) and somatostatin (δ) producing cells in the pancreatic islets of 11weeks old R6/2 Huntington's Disease transgenic (HD tg) and age-matched wild type (wt) mice. We also determined expression of tyrosine hydroxylase (TH), glutamic acid decarboxylase (GAD) and presynaptic marker synaptophysin (SYP) in addition to signal transduction pathways associated with diabetes. In R6/2 mice, islets are relatively smaller in size, exhibit enhanced expression and nuclear inclusion of mHtt along with the loss of insulin, glucagon and somatostatin expression. In comparison to wt, R6/2 mice display enhanced mRNA for all SSTRs except SSTR2. In the pancreatic lysate, SSTR1, 4 and 5 immunoreactivity decreases whereas SSTR3 immunoreactivity increases with no discernible changes in SSTR2 immunoreactivity. Furthermore, at the cellular level, R6/2 mice exhibit a receptor specific distributional pattern of SSTRs like immunoreactivity and colocalization with β, α and δ cells. While GAD expression is increased, TH and SYP immunoreactivity was decreased in R6/2 mice, anticipating a cross-talk between the CNS and pancreas in diabetes pathophysiology. We also dissected out the changes in signaling pathway and found decreased activation and expression of PKA, AKT, ERK1/2 and STAT3 in R6/2 mice pancreas. These findings suggest that the impaired organization of SSTRs within islets may lead to perturbed hormonal regulation and signaling. These interconnected complex events might shed new light on the pathogenesis of diabetes in neurodegenerative diseases and the role of SSTRs in potential therapeutic intervention. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  3. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  4. Low dose radiation enhance the anti-tumor effect of high dose radiation on human glioma cell U251

    International Nuclear Information System (INIS)

    Wang Chang; Wang Guanjun; Tan Yehui; Jiang Hongyu; Li Wei

    2008-01-01

    Objective: To detect the effect on the growth of human glioma cell U251 induced by low dose irradiation and low dose irradiation combined with large dose irradiation. Methods: Human glioma cell line U251 and nude mice carried with human glioma were used. The tumor cells and the mice were treated with low dose, high dose, and low dose combined high dose radiation. Cells growth curve, MTT and flow cytometry were used to detect the proliferation, cell cycle and apoptosis of the cells; and the tumor inhibition rate was used to assess the growth of tumor in vivo. Results: After low dose irradiation, there was no difference between experimental group and control group in cell count, MTT and flow cytometry. Single high dose group and low dose combined high dose group both show significantly the suppressing effect on tumor cells, the apoptosis increased and there was cell cycle blocked in G 2 period, but there was no difference between two groups. In vivo apparent anti-tumor effect in high dose radiation group and the combining group was observed, and that was more significant in the combining group; the prior low dose radiation alleviated the injury of hematological system. There was no difference between single low dose radiation group and control. Conclusions: There is no significant effect on human glioma cell induced by low dose radiation, and low dose radiation could not induce adaptive response. But in vivo experience, low dose radiation could enhance the anti-tumor effect of high dose radiation and alleviated the injury of hematological system. (authors)

  5. Experimental peptide receptor radionuclide therapy in radioiodine negative somatostatin receptor positive thyroid cancer

    International Nuclear Information System (INIS)

    Nilica, B.; Kroiss, A.; Putzer, D.; Uprimmy, C.; Warwitz, B.; Kendler, D.; Waitz, D.; Virgolini, I.

    2015-01-01

    Full text of publication follows. Purpose: This retrospective analysis evaluated the time to progression (TTP), progression free survival (PFS) and overall survival (OS) in patients with radioiodine negative thyroid cancer who had undergone peptide receptor radionuclide therapy (PRRT) with 177 Lu-DOTA-TATE, 177 Lu-DOTA-LAN, 90 Y-DOTA-TOC or 90 Y-DOTA-LAN after tumor progression. Methods: Data derived from twenty patients with either differentiated (n=15), anaplastic (n=1) or medullary (n=4) somatostatin receptor positive thyroid cancer who had received treatment with PRRT after tumor progression. TTP, PFS and OS were defined according to the clinical trial endpoints suggested by the FDA (Food and Drug Administration). Progressive disease was defined by sonography, FDG-PET, Ga-DOTA-TOC-PET, or CT (RECIST Criteria). Results: In 17 patients the median overall survival time after the first PRRT was 17.3 (range: 0.1 - 109.7) months. Three patients still alive are actually showing stable disease. The median of PFS in 20 Patients (6 with more than one PRRT-cycle or PRRT-substance) has been 10.9 (range: 0.1 - 44.0) months. The median TTP was 15.6 (range 4.4 to 29.2) months. Conclusion: PRRT appears to be useful in patients with somatostatin receptor positive but radioiodine negative thyroid cancer as a complementary palliative cytotoxic therapy. (authors)

  6. Somatostatin receptor expression in the human spleen - Answer to an enigma by ex-vivo and in-vitro autoradiography after 177Lu-DOTA-octreotate administration

    International Nuclear Information System (INIS)

    Melis, M.; Swart, J. de; Groen, H.C.; Konijnenberg, M.W.; Van der Graaf, L.M.; Kaemmerer, D.; Kulkami, H.R.; Baum, R.P.; Lupp, A.; Saenger, J.; Jong, M. de

    2015-01-01

    Full text of publication follows. Aim: radiolabelled somatostatin analogues are being used for diagnostic and therapeutic (PRRT) purposes in patients with somatostatin receptor (SSTR) expressing tumours. During PRRT a significant spleen uptake may lead to radiation doses of > 20 Gy. Yet, the threshold dose for spleen radiation induced toxicity is currently unknown. Based on previous 68 Ga-DOTATOC PET/CT studies, demonstrating higher uptake in spleen than in splenosis, white pulp (WP) localization of radioactivity was suggested. This hypothesis was investigated in the current pilot study using the longer lived 177 Lu-DOTA-octreotate. Methods: a patient diagnosed with neuroendocrine neoplasm of the pancreatic tail (SUV max on 68 Ga-DOTATOC PET/CT 100.4) with liver metastasis (SUV 47.3, normal liver SUV 12.5) and uptake in the spleen (SUV 41.0) received 1 GBq 177 Lu-DOTA-octreotate. 2 h after administration whole-body planar scintigraphy and SPECT/CT of the upper abdomen was performed, followed by laparoscopic resection of the pancreatic tumour and splenectomy the next day. After spleen transport from Bad Berka to Rotterdam ex-vivo micro-SPECT of the removed spleen was acquired for 73 min using 2.5 mm diameter pinholes. Spleen fragments (∼10 * 10 * 5 mm) were either snap-frozen in liquid nitrogen or fixed in 10% formalin and paraffin embedded. Ex-vivo autoradiography of 10 μm cryo-sections was performed and serial sections were used for 111 In-DOTA-octreotate in-vitro autoradiography after decay of 177 Lu. FFPE sections were used for HE- and immunostaining for SSTR2A and cell subsets CD4 (Th-cell), CD8 (Ts-cell), CD20 (B-cell) and CD68 (macrophage). Results: 177 Lu-DOTA-octreotate scintigraphy and SPECT/CT demonstrated high uptake in the pancreatic tumor, hepatic metastasis and homogeneously in the normal spleen. High resolution micro-SPECT imaging of the isolated spleen also revealed a relatively homogeneous uptake (calculated rest activity 60 MBq 177 Lu). The

  7. 99mTc-N4-[Tyr3]Octreotate Versus 99mTc-EDDA/HYNIC-[Tyr3]Octreotide: an intrapatient comparison of two novel Technetium-99m labeled tracers for somatostatin receptor scintigraphy.

    Science.gov (United States)

    Gabriel, Michael; Decristoforo, Clemens; Maina, Theodosia; Nock, Berthold; vonGuggenberg, Elisabeth; Cordopatis, Paul; Moncayo, Roy

    2004-02-01

    Tetraamine-[Tyr3]octreotate (Demotate) is a somatostatin (SST) analogue that can be easily labeled with 99mTc at high specific activities and showed promising preclinical properties for SST receptor scintigraphy. This study reports on the first intra-patient comparison of 99mTc-Demotate and another 99mTc-labeled SST analogue, 99mTc-EDDA/HYNIC-TOC (HYNIC-TOC). Five patients with carcinoid tumors (n = 2) and endocrine pancreatic tumors (n = 3) were investigated with both radiopharmaceuticals. 99mTc-Demotate rapidly visualized somatostatin receptor positive tumors as early as 15 minutes post-injection (p.i.) with maximum tumor uptake and tumor/organ ratios already 1 hour p.i. Organs of predominant physiological uptake were the spleen and the kidneys with no intestinal excretion detectable up to 24 hours. 99mTc-Demotate exhibited faster pharmacokinetic properties compared to HYNIC-TOC. Tumor/organ ratios at equivalent time points were higher or comparable for 99mTc-Demotate in three patients with a matching scan result. Equivocal findings were observed in two patients, i.e. comparable uptake behavior in larger lesions with differences in smaller ones. 99mTc-Demotate is a promising agent for somatostatin receptor scintigraphy providing images of excellent quality as early as 1 hour after injection.

  8. NIST high-dose calibration services

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1989-01-01

    There is a need for the standardization of high-dose measurements used in the radiation-processing industry in order to provide assured traceability to national standards. NIST provides dosimetry calibration services to this industry. One of these services involves administration of known absorbed doses of gamma rays to customer-supplied dosimeters. The dosimeters are packaged to provide electron equilibrium conditions and are irradiated in a standard 60 Co calibration facility; this provides a calibration of that batch of dosimeters. Another service consists of supplying to a customer calibrated transfer dosimeters for irradiation with the customer's radiation source. The irradiated transfer dosimeters are then returned to NIST for analysis; the results are reported to the customer, providing a calibration of the dose rate of the customer's source. (orig.)

  9. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer

    International Nuclear Information System (INIS)

    Oliveira, Jetro Pereira de; Batista, Delano Valdivino Santos; Bardella, Lucia Helena; Carvalho, Arnaldo Rangel

    2009-01-01

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  10. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    Science.gov (United States)

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.

  11. Translational Advancement of Somatostatin Gene Delivery for Disease Modification and Cognitive Sparing in Intractable Epilepsy

    Science.gov (United States)

    2015-09-01

    seizures. A thoroughly characterized rodent epilepsy model will be used as a platform to test the hypotheses. In this model temporal lobe electrical...expression in the hippocampus resected from a young temporal lobe epilepsy patient. Post-baccalaureate student Andrew Moss has since expanded this project...somatostatin gene delivery persistently reduces seizure severity in a rat model of temporal lobe epilepsy , Gowri Natarajan, Jessica Anne McElroy

  12. Effects of +G_z exposure on gallbladder emptying function,cholecystokinin,and somatostatin in rabbits with high cholesterol diets

    Directory of Open Access Journals (Sweden)

    Guo-feng XIAO

    2011-12-01

    Full Text Available Objective The present study explores the effects of +Gz exposure on the gallbladder emptying function,cholecystokinin(CCK,and somatostatin(SS in rabbits with high cholesterol diets and investigates its mechanism in the occurrence of cholecystolithiasis.Methods Twenty-four male New Zealand rabbits were randomly divided into the high cholesterol diet(control group,n=8 and high cholesterol diet plus +Gz exposure groups.The latter was divided into the four-and six-week +Gz exposure groups(n=8 based on the exposure time.Radioimmunoassay was used to determine the CCK and SS contents of the gallbladder at the end of the experiment in the fourth and sixth weeks and to calculate the gallbladder volume and maximum emptying ratio.A microcomputer biodynamic pressure monitor was used to record the hydrostatic pressure in the gallbladder to measure its capacity.Moreover,the bile properties and formation of concretion were observed with the naked eye,and polarized light microscopy was used to observe cholesterin crystallization on the gallbladder wall.Results The gallbladder capacity increased upon +Gz exposure for four and six weeks,indicating that the maximum emptying ratio(E% decreased,the empty and residual volumes improved,and the pressure increased(P < 0.05.After +Gz exposure for four and six weeks,the CCK contents in the experimental groups were evidently lower than that in the control group and gradually decreased(P < 0.05 as the +Gz exposure time increased.On the other hand,after +Gz exposure for four and six weeks,the SS contents in the experimental groups were higher than that in the control group and gradually improved(P < 0.05 as the +Gz exposure time increased.After +Gz exposure for four and six weeks,bile was turbid and sticky with cholesterol crystals and without visible concretion.Conclusions Therefore,+Gz exposure may cause abnormal gallbladder emptying functions,decrease CCK content,increase SS content,and thus cause bile stasis

  13. Investigation of polymer composite for high dose dosimetry

    International Nuclear Information System (INIS)

    Pereira, E.L.M.; Batista, A.S.M.; Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H.

    2017-01-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO 2 ) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm -1 and 1730 cm -1 can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm -1 and 1730 cm -1 whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  14. Effect of Peptide Receptor Radionuclide Therapy on Somatostatin Receptor Status and Glucose Metabolism in Neuroendocrine Tumors: Intraindividual Comparison of Ga-68 DOTANOC PET/CT and F-18 FDG PET/CT

    Science.gov (United States)

    Oh, Sowon; Prasad, Vikas; Lee, Dong Soo; Baum, R. P.

    2011-01-01

    The heterogeneous nature of the neuroendocrine tumors (NET) makes it challenging to find one uniformly applicable management protocol which is especially true for diagnosis. The discovery of the overexpression of somatostatin receptors (SMS-R) on neuroendocrine tumor cells lead to the generalized and rapid acceptance of radiolabeled somatostatin receptor analogs for staging and restaging of NET as well as for Peptide Receptor Radionuclide Therapy (PRRNT) using Y-90 and Lu-177 DOTATATE/DOTATOC. In this present work we tried to look in to the effect of PRRNT on the glucose metabolism assessed by F-18 FDG PET/CT and SMS-R density assessed by Ga-68 DOTANOC PET/CT. We observed a complex relationship between the somatostatin receptor expression and glucose metabolism with only 56% (77/138) of the lesions showing match, while the others show mismatch between the receptor status and metabolism. The match between receptor expression and glucose metabolism increases with the grade of NET. In grade 3 NET, there is a concurrence between the changes in glucose metabolism and somatostatin receptor expression. PRRNT was found to be more effective in lesions with higher receptor expression. PMID:22121482

  15. Statistical behavior of high doses in medical radiodiagnosis

    International Nuclear Information System (INIS)

    Barboza, Adriana Elisa

    2014-01-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  16. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  17. In vivo binding of [68Ga]-DOTATOC to somatostatin receptors in neuroendocrine tumours - impact of peptide mass

    International Nuclear Information System (INIS)

    Velikyan, Irina; Sundin, Anders; Eriksson, Barbro; Lundqvist, Hans; Soerensen, Jens; Bergstroem, Mats; Langstroem, Bengt

    2010-01-01

    Objectives: The aim of this pilot study was to explore the impact of peptide mass on binding of [ 68 Ga]-DOTATOC to neuroendocrine tumour somatostatin receptors in vivo using a tracer of variable specific radioactivity (SRA) and to show the logistic feasibility of sequential PET scans in the same patient. Material and Methods: Nine patients with gastroenteropancreatic neuroendocrine tumours were included. Six of them underwent three sequential PET-CT examinations with intravenous injections of [ 68 Ga]-DOTATOC proceeded by 0, 50 and 250 or 500 μg of octreotide, administered 10 min before the tracer. Three patients were examined by dynamic and static PET/CT for pharmacokinetic and dosimetric calculations. The [ 68 Ga]-DOTATOC synthesis included preconcentration and purification of the generator eluate and microwave heating in a semi-automated in-house procedure. Results: [ 68 Ga]-DOTATOC synthesis and quality control were accomplished within 30 min and radiochemical purity was >95%. The tracer accumulation in the tumours varied and depended on the total amount of the administered peptide. In five of six patients, the highest tumour-to-normal tissue ratio was found when 50 μg of octreotide was preadministered. One patient showed a continuously increasing tumour uptake. Dosimetrically, a large variation in organ doses was found (kidney: 0.086-0.168 mSv/MBq; liver: 0.026-0.096 mSv/MBq; spleen: 0.046-0.226 mSv/MBq). The effective dose (0.015, 0.0067 and 0.0042 mSv/MBq) was correlated to the total amount of decays. Discussion: Three sequential PET-CT examinations using 68 Ga-based tracer was carried out in 1 day. The use of high SRA [ 68 Ga]-DOTATOC and unlabelled octreotide indicates an optimal mass leading to better image contrast. [ 68 Ga]-DOTATOC-PET-CT employing variable SRA may be utilised for accurate quantification of tumour uptake with subsequent dosimetry for personalized therapy management.

  18. Somatostatine analogs marked with 99m-TC

    International Nuclear Information System (INIS)

    Obenaus, E; Crudo, J; Edreira, M; Castiglia, S.G. de

    2003-01-01

    The aim of the present work was to study the biological and radiochemical behaviour of two somatostatin analogues, the RC-160 and Tyr 3 Octreotide(TOC) peptides when labeling with 99m Tc by an indirect method using S-Benzoyl- mercaptoacetyl triglycine (MAG3) and hydrazino nicotinamide (HYNIC) as chelating agents. The synthesis of RC160 with S-Benzoyl MAG3 and TOC with HYNIC, for labeling with 99m Tc are also described. The conjugates were prepared on a small scale and labeled with the radionuclide using tricine as coligands for HYNIC conjugates. Chromatographic studies were performed using an HPLC system and radiochemical purities higher than 75% and 95% were obtained respectively. Biodistributions studies in normal Wistar rats were performed and results were correlated with chromatographic and protein binding properties. Lower lipophilicity of the labeled conjugates resulted in a higher renal excretion. HYNIC-TOC complex showed promising results when labeling with 99m Tc using tricine as coligand although higher stability should be found for ternary coligands compared to tricine (Au)

  19. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de Araujo

    2005-01-01

    Industrial gamma irradiators facilities are designed for processing large amounts of products, which are exposed to large doses of gamma radiation. The irradiation, in industrial scale, is usually carried out in a dynamic form, where the products go through a 60 Co gamma source with activity of TBq to P Bq (k Ci to MCi). The dose is estimated as being directly proportional to the time that the products spend to go through the source. However, in some situations, mainly for research purposes or for validation of customer process following the ISO 11137 requirements, it is required to irradiate small samples in a static position with fractional deliver doses. The samples are put inside the irradiation room at a fixed distance from the source and the dose is usually determined using dosimeters. The dose is only known after the irradiation, by reading the dosimeter. Nevertheless, in the industrial irradiators, usually different kinds of products with different densities go through between the source and the static position samples. So, the dose rate varies in function of the product density. A suitable methodology would be to monitor the samples dose in real time, measuring the dose on line with a radiation detector, which would improve the dose accuracy and avoid the overdose. A cylindrical ionization chamber of 0.9 cm 3 has been developed for high-doses real-time monitoring, during the sample irradiation at a static position in a 60 Co gamma industrial plant. Nitrogen and argon gas at pressure of 10 exp 5 Pa (1 bar) was utilized to fill the ionization chamber, for which an appropriate configuration was determined to be used as a detector for high-dose measurements. To transmit the signal generated in the ionization chamber to the associated electronic and processing unit, a 20 m mineral insulated cable was welded to the ionization chamber. The signal to noise ratio produced by the detector was about 100. The dosimeter system was tested at a category I gamma

  20. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  1. Somatostatin and opioid receptors do not regulate proliferation or apoptosis of the human multiple myeloma U266 cells

    Directory of Open Access Journals (Sweden)

    Allouche Stéphane

    2009-06-01

    Full Text Available Abstract Background opioid and somatostatin receptors (SSTRs that can assemble as heterodimer were individually reported to modulate malignant cell proliferation and to favour apoptosis. Materials and methods: SSTRs and opioid receptors expression were examined by RT-PCR, western-blot and binding assays, cell proliferation was studied by XTT assay and propidium iodide (PI staining and apoptosis by annexin V-PI labelling. Results almost all human malignant haematological cell lines studied here expressed the five SSTRs. Further experiments were conducted on the human U266 multiple myeloma cells, which express also μ-opioid receptors (MOP-R. XTT assays and cell cycle studies provide no evidence for a significant effect upon opioid or somatostatin receptors stimulation. Furthermore, neither direct effect nor potentiation of the Fas-receptor pathway was detected on apoptosis after these treatments. Conclusion these data suggest that SSTRs or opioid receptors expression is not a guaranty for an anti-tumoral action in U266 cell line.

  2. Pharmacogenetics and Pharmacokinetics in high-dose alkylating chemotherapy

    NARCIS (Netherlands)

    Ekhart, G.C. (Corine)

    2008-01-01

    High-dose chemotherapy in combination with peripheral blood progenitor cell transplantation has been developed as a possible curative treatment modality in several solid tumours. A frequently used high-dose regimen in the Netherlands is the CTC regimen, which is a 4-day course of cyclophosphamide,

  3. Establishment and verification of dose-response curve of chromosomal aberrations after exposure to very high dose γ-ray

    International Nuclear Information System (INIS)

    Chen Ying; Luo Yisheng; Cao Zhenshan; Liu Xiulin

    2006-01-01

    To estimate accurately biological dose of the victims exposed to high dose, the dose-response curves of chromosome aberration induced by 6-22 Gy 60 Co γ-ray were established. Human peripheral blood in vitro was irradiated, then lymphocytes were concentrated, cultured 52h, 68h and 72h and harvested. The frequencies of dicentrics (multi-centrics) and rings were counted and compared between different culture times. The dose-response curves and equations were established, as well as verified with high dose exposure accidents. The experiment showed that the culture time should be prolonged properly after high dose exposure, and no significant differences were observed between 52-72h culture. The dose-response curve of 6-22 Gy fitted to linear-square model Y=-2.269 + 0.776D - 7.868 x 10 -3 D 2 and is reliable through verification of the accident dose estimations. In this study, the dose-response curve and equation of chromosome dic + r after 6-22 Gy high dose irradiation were established firstly, and exact dose estimation can be achieved according to it. (authors)

  4. Influence of PET/CT 68Ga somatostatin receptor imaging on proceeding with patients, who were previously diagnosed with 99mTc-EDDA/HYNIC-TOC SPECT.

    Science.gov (United States)

    Madrzak, Dorota; Mikołajczak, Renata; Kamiński, Grzegorz

    2016-01-01

    were assigned as follows: TP, TN (in cases where the results were confirmed by 68Ga PET/CT), FP (patient's scintigraphy demonstrated focal change by SPECT but not PET/CT) and FN (99mTc-EDDA/HYNIC-Tyr3-octreotide SPECT failed to demonstrate any abnormalities; however, the treatment protocol was changed after PET/CT). The accuracy of SPECT diagnosis was found to be as high as 91.6%. Only in 8.4% of patients the additional PET/CT with 68Ga-labeled somatostatin analog changed the treatment protocol.

  5. Nonlinear model of high-dose implantation

    International Nuclear Information System (INIS)

    Danilyuk, A.

    2001-01-01

    The models of high-dose implantation, using the distribution functions, are relatively simple. However, they must take into account the variation of the function of distribution of the implanted ions with increasing dose [1-4]. This variation takes place owing to the fact that the increase of the concentration of the implanted ions results in a change of the properties of the target. High-dose implantation is accompanied by sputtering, volume growth, diffusion, generation of defects, formation of new phases, etc. The variation of the distribution function is determined by many factors and is not known in advance. The variation within the framework of these models [1-4] is taken into account in advance by the introduction of intuitive assumptions on the basis of implicit considerations. Therefore, these attempts should be regarded as incorrect. The model prepared here makes it possible to take into account the sputtering of the target, volume growth and additional declaration on the implanted ions. Without any assumptions in relation to the variation of the distribution function with increasing dose. In our model it is assumed that the type of distribution function for small doses in a pure target substance is the same as in substances with implanted ions. A second assumption relates to the type of the distribution function valid for small doses in the given substances. These functions are determined as a result of a large number of theoretical and experimental investigations and are well-known at the present time. They include the symmetric and nonsymmetric Gauss distribution, the Pearson distribution, and others. We examine implantation with small doses of up to 10 14 - 10 15 cm -2 when the accurately known distribution is valid

  6. High-dose gadolinium-enhanced MRI for diagnosis of meningeal metastases

    International Nuclear Information System (INIS)

    Kallmes, D.F.; Gray, L.; Glass, J.P.

    1998-01-01

    We compared high-dose (0.3 mmol/kg) and standard-dose (0.1 mmol/kg) gadolinium-enhanced MRI for diagnosis of meningeal metastases in 12 patients with suspected meningeal metastases. They were imaged with both standard-dose and high-dose gadolinium. All patients with abnormal meningeal enhancement underwent at least one lumbar puncture for cerebrospinal fluid (CSF) cytology, while patients with normal meningeal enhancement were followed clinically. All patients with negative CSF cytology also were followed clinically. A single observer reviewed all the images, with specific attention to the enhancement pattern of the meninges. Abnormal leptomeningeal enhancement was present in three cases, and abnormal pachymeningeal enhancement in three other patients. All of these patients had abnormal CSF analyses. In two of the three cases of abnormal leptomeningeal enhancement the disease was more evident on high-dose than on standard-dose imaging; in one case the abnormal enhancement was visible only on high-dose imaging. In one of the three cases with abnormal pachymeningeal enhancement, the disease was evident prospectively only with high-dose imaging. (orig.)

  7. Investigation of polymer composite for high dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, E.L.M.; Batista, A.S.M., E-mail: adriananuclear@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO{sub 2}) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm{sup -1} and 1730 cm{sup -1} can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm{sup -1} and 1730 cm{sup -1} whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  8. Methodology of high dose research in medical radiodiagnostic

    International Nuclear Information System (INIS)

    Barboza, Adriana E.; Martins, Cintia P. de S.

    2013-01-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations

  9. High-dose preoperative radiation for cancer of the rectum: Impact of radiation dose on patterns of failure and survival

    International Nuclear Information System (INIS)

    Ahmad, N.R.; Mohiuddin, M.; Marks, G.

    1993-01-01

    A variety of dose-time schedules are currently used for preoperative radiation therapy of rectal cancer. An analysis of patients treated with high-dose preoperative radiation therapy was undertaken to determine the influence of radiation dose on the patterns of failure, survival, and complications. Two hundred seventy-five patients with localized rectal cancer were treated with high-dose preoperative radiation therapy. One hundred fifty-six patients received 45 Gy (low-dose group). Since 1985, 119 patients with clinically unfavorable cancers were given a higher dose, 55 Gy using a shrinking field technique (high-dose group). All patients underwent curative resection. Median follow-up was 66 months in the low-dose group and 28 months in the high-dose group. Patterns of failure, survival, and complications were analyzed as a function of radiation dose. Fourteen percent of the total group developed a local recurrence; 20% in the low-dose group as compared with 6% in the high-dose group. The actuarial local recurrence rate at 5 years was 20% for the low-dose group and 8% for the high-dose group, and approached statistical significance with p = .057. For tethered/fixed tumors the actuarial local recurrence rates at 5 years were 28% and 9%, respectively, with p = .05. Similarly, for low-lying tumors (less than 6 cm from the anorectal junction) the rates were 24% and 9%, respectively, with p = .04. The actuarial rate of distant metastasis was 28% in the low-dose group and 20% in the high-dose group and was not significantly different. Overall actuarial 5-year survival for the total group of patients was 66%. No significant difference in survival was observed between the two groups, despite the higher proportion of unfavorable cancers in the high-dose group. The incidence of complications was 2%, equally distributed between the two groups. High-dose preoperative radiation therapy for rectal cancer results in excellent local control rates. 27 refs., 2 figs., 8 tabs

  10. Acute renal failure in high dose carboplatin chemotherapy

    NARCIS (Netherlands)

    Frenkel, J.; Kool, G.; de Kraker, J.

    1995-01-01

    Carboplatin has been reported to cause acute renal failure when administered in high doses to adult patients. We report a 4 1/2-year-old girl who was treated with high-dose carboplatin for metastatic parameningeal embryonal rhabdomyosarcoma. Acute renal failure developed followed by a slow partial

  11. Dose intercomparison studies for standardization of high-dose dosimetry in Viet Nam

    International Nuclear Information System (INIS)

    Mai Hoang Hoa; Duong Nguyen Dinh; Kojima, T.

    1999-01-01

    The Irradiation Center of the Vietnam Atomic Energy Commission (IC-VAEC) is planning to establish a traceability system for high-dose dosimetry and to provide high-dose standards as a secondary standard dosimetry laboratory (SSDL) level in Vietnam. For countries which do not have a standard dosimetry laboratory, the participation in the International Dose Assurance Service (IDAS) operated by the International Atomic Energy Agency (IAEA) is the most common means to verify own dosimetry performance with a certain uncertainty. This is, however, only one-direction dose intercomparison with evaluation by IAEA including unknown parameter at participant laboratories. The SSDL level laboratory should have traceability as well as compatibility, ability to evaluate uncertainties of its own dosimetry performance by itself In the present paper, we reviewed our dosimetry performance through two-way dose intercomparison studies and self-evaluation of uncertainty in our dosimetry procedure. The performance of silver dichromate dosimeter as reference transfer dosimeter in IC-VAEC was studied through two-way blind dose intercomparison experiments between the IC-VAEC and JAERI. As another channel of dose intercomparison with IAEA, alanine dosimeters issued by IDAS were simultaneously irradiated with the IC-VAEC dichromate dosimeters at IC-VAEC and analyzed by IAEA. Dose intercomparison between IC-VAEC and JAERI results into a good agreement (better than ±2.5%), and IDAS results also show similar agreement within ±3.0%. The uncertainty was self-estimated on the basis of the JAERI alanine dosimetry, and a preliminary value of about 1.86% at a 68% confidence level is established. The results from these intercomparisons and our estimation of the uncertainty are consistent. We hope that our experience is valuable to other countries which do not have dosimetry standard laboratories and/or are planning to establish them. (author)

  12. Development of antibodies against the rat brain somatostatin receptor.

    Science.gov (United States)

    Theveniau, M; Rens-Domiano, S; Law, S F; Rougon, G; Reisine, T

    1992-05-15

    Somatostatin (SRIF) is a neurotransmitter in the brain involved in the regulation of motor activity and cognition. It induces its physiological actions by interacting with receptors. We have developed antibodies against the receptor to investigate its structural properties. Rabbit polyclonal antibodies were generated against the rat brain SRIF receptor. These antibodies (F4) were able to immunoprecipitate solubilized SRIF receptors from rat brain and the cell line AtT-20. The specificity of the interaction of these antibodies with SRIF receptors was further demonstrated by immunoblotting. F4 detected SRIF receptors of 60 kDa from rat brain and adrenal cortex and the cell lines AtT-20, GH3, and NG-108, which express high densities of SRIF receptors. They did not detect immunoreactive material from rat liver or COS-1, HEPG, or CRL cells, which do not express functional SRIF receptors. In rat brain, 60-kDa immunoreactivity was detected by F4 in the hippocampus, cerebral cortex, and striatum, which have high densities of SRIF receptors. However, F4 did not interact with proteins from cerebellum and brain stem, which express few SRIF receptors. Immunoreactive material cannot be detected in rat pancreas or pituitary, which have been reported to express a 90-kDa SRIF receptor subtype. The selective detection of 60-kDa SRIF receptors by F4 indicates that the 60- and 90-kDa SRIF receptor subtypes are immunologically distinct. The availability of antibodies that selectively detect native and denatured brain SRIF receptors provides us with a feasible approach to clone the brain SRIF receptor gene(s).

  13. High-dose contrast-enhanced MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Koudriavtseva, T.; Pozzilli, C.; Di Biasi, C.; Iannilli, M.; Trasimeni, G.; Gasperini, C.; Argentino, C.; Gualdi, G.F.

    1996-01-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs

  14. High-dose contrast-enhanced MRI in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Koudriavtseva, T. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Pozzilli, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Di Biasi, C. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Iannilli, M. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Trasimeni, G. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Gasperini, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Argentino, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Gualdi, G.F. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy)

    1996-05-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs.

  15. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  16. THE EFFECT OF THE SOMATOSTATIN ANALOGUE OCTREOTIDE ON EXPERIMENTAL INTESTINAL OBSTRUCTION IN RATS

    Directory of Open Access Journals (Sweden)

    Paran Haim

    1998-01-01

    Full Text Available Background: Somatostatin has an inhibitory effect on the endocrine and exocrine secretions of the gut. It may have a beneficial effect in the conservative treatment of intestinal obstruction. The aim of the present study is to investigate the effect of octreotide in mechanical intestinal obstruction in rats. Method: Intestinal obstruction was induced in rats by ligation of a segment of the distal ileum. Animals were treated with the somatostatin analogue octreotide (n=16, or saline (n=16. Eight rats were operated but their intestine was not ligated (n=8 serving as sham controls. Forty eight hours after the operation, the animals were operated upon again and blood samples from the femoral vein were tested for electrolytes, urea, glucose, lactic acid, amylase, ph and bicarbonate. Portal vein blood samples were also obtained and tested for lactic acid and amylase. Results: Intestinal obstruction resulted, after 48 hours, in severe dilatation of bowel loops. A significant increase in plasma levels of urea, amylase and lactic acid was observed. Plasma pH decreased. In blood samples from the portal vein, a significant increase in lactic acid was observed, indicating metabolic acidosis, probably secondary to bowel ischemia. Octreotide treatment, resulted in less acidosis, with concomitant lower urea and lactic acid levels in the plasma and especially in the portal vein. Conclusion: Octreotide treatment may have a beneficial effect in the conservative treatment of selected cases of intestinal obstruction.

  17. Osilodrostat (LCI699), a potent 11β-hydroxylase inhibitor, administered in combination with the multireceptor-targeted somatostatin analog pasireotide: A 13-week study in rats

    Energy Technology Data Exchange (ETDEWEB)

    Li, Li, E-mail: li1.li@novartis.com [Preclinical Safety, Novartis Institutes for BioMedical Research, East Hanover, NJ (United States); Vashisht, Kapil; Boisclair, Julie [Preclinical Safety, Novartis Institutes for BioMedical Research, East Hanover, NJ (United States); Li, Wenkui; Lin, Tsu-han [Drug Metabolism and Pharmacokinetics, Novartis Institutes for BioMedical Research, East Hanover, NJ (United States); Schmid, Herbert A. [Novartis Oncology Development, Basel (Switzerland); Kluwe, William; Schoenfeld, Heidi; Hoffmann, Peter [Preclinical Safety, Novartis Institutes for BioMedical Research, East Hanover, NJ (United States)

    2015-08-01

    The somatostatin analog pasireotide and the 11β-hydroxylase inhibitor osilodrostat (LCI699) reduce cortisol levels by distinct mechanisms of action. There exists a scientific rationale to investigate the clinical efficacy of these two agents in combination. This manuscript reports the results of a toxicology study in rats, evaluating different doses of osilodrostat and pasireotide alone and in combination. Sixty male and 60 female rats were randomized into single-sex groups to receive daily doses of pasireotide (0.3 mg/kg/day, subcutaneously), osilodrostat (20 mg/kg/day, orally), osilodrostat/pasireotide in combination (low dose, 1.5/0.03 mg/kg/day; mid-dose, 5/0.1 mg/kg/day; or high dose, 20/0.3 mg/kg/day), or vehicle for 13 weeks. Mean body-weight gains from baseline to Week 13 were significantly lower in the pasireotide-alone and combined-treatment groups compared to controls, and were significantly higher in female rats receiving osilodrostat monotherapy. Osilodrostat and pasireotide monotherapies were associated with significant changes in the histology and mean weights of the pituitary and adrenal glands, liver, and ovary/oviduct. Osilodrostat alone was associated with adrenocortical hypertrophy and hepatocellular hypertrophy. In combination, osilodrostat/pasireotide did not exacerbate any target organ changes and ameliorated the liver and adrenal gland changes observed with monotherapy. C{sub max} and AUC{sub 0–24h} of osilodrostat and pasireotide increased in an approximately dose-proportional manner. In conclusion, the pasireotide and osilodrostat combination did not exacerbate changes in target organ weight or toxicity compared with either monotherapy, and had an acceptable safety profile; addition of pasireotide to the osilodrostat regimen may attenuate potential adrenal gland hyperactivation and hepatocellular hypertrophy, which are potential side effects of osilodrostat monotherapy. - Highlights: • We examined the target organ toxicity of SOM230

  18. Tumour control probability derived from dose distribution in homogeneous and heterogeneous models: assuming similar pharmacokinetics, 125Sn–177Lu is superior to 90Y–177Lu in peptide receptor radiotherapy

    International Nuclear Information System (INIS)

    Walrand, Stephan; Hanin, François-Xavier; Pauwels, Stanislas; Jamar, François

    2012-01-01

    Clinical trials on 177 Lu– 90 Y therapy used empirical activity ratios. Radionuclides (RN) with larger beta maximal range could favourably replace 90 Y. Our aim is to provide RN dose-deposition kernels and to compare the tumour control probability (TCP) of RN combinations. Dose kernels were derived by integration of the mono-energetic beta-ray dose distributions (computed using Monte Carlo) weighted by their respective beta spectrum. Nine homogeneous spherical tumours (1–25 mm in diameter) and four spherical tumours including a lattice of cold, but alive, spheres (1, 3, 5, 7 mm in diameter) were modelled. The TCP for 93 Y, 90 Y and 125 Sn in combination with 177 Lu in variable proportions (that kept constant the renal cortex biological effective dose) were derived by 3D dose kernel convolution. For a mean tumour-absorbed dose of 180 Gy, 2 mm homogeneous tumours and tumours including 3 mm diameter cold alive spheres were both well controlled (TCP > 0.9) using a 75–25% combination of 177 Lu and 90 Y activity. However, 125 Sn– 177 Lu achieved a significantly better result by controlling 1 mm-homogeneous tumour simultaneously with tumours including 5 mm diameter cold alive spheres. Clinical trials using RN combinations should use RN proportions tuned to the patient dosimetry. 125 Sn production and its coupling to somatostatin analogue appear feasible. Assuming similar pharmacokinetics 125 Sn is the best RN for combination with 177 Lu in peptide receptor radiotherapy justifying pharmacokinetics studies in rodent of 125 Sn-labelled somatostatin analogues. (paper)

  19. Update on pediatric resuscitation drugs: high dose, low dose, or no dose at all.

    Science.gov (United States)

    Sorrentino, Annalise

    2005-04-01

    Pediatric resuscitation has been a topic of discussion for years. It is difficult to keep abreast of changing recommendations, especially for busy pediatricians who do not regularly use these skills. This review will focus on the most recent guidelines for resuscitation drugs. Three specific questions will be discussed: standard dose versus high-dose epinephrine, amiodarone use, and the future of vasopressin in pediatric resuscitation. The issue of using high-dose epinephrine for cardiopulmonary resuscitation refractory to standard dose epinephrine has been a topic of debate for many years. Recently, a prospective, double-blinded study was performed to help settle the debate. These results will be reviewed and compared with previous studies. Amiodarone is a medication that was added to the pediatric resuscitation algorithms with the most recent recommendations from the American Heart Association in 2000. Its use and safety will also be discussed. Another topic that is resurfacing in resuscitation is the use of vasopressin. Its mechanism and comparisons to other agents will be highlighted, although its use in the pediatric patient has not been thoroughly studied. Pediatric resuscitation is a constantly evolving subject that is on the mind of anyone taking care of sick children. Clinicians are continually searching for the most effective methods to resuscitate children in terms of short- and long-term outcomes. It is important to be familiar with not only the agents being used but also the optimal way to use them.

  20. Disinhibition in learning and memory circuits: New vistas for somatostatin interneurons and long-term synaptic plasticity.

    Science.gov (United States)

    Artinian, Julien; Lacaille, Jean-Claude

    2017-11-23

    Neural circuit functions involve finely controlled excitation/inhibition interactions that allow complex neuronal computations and support high order brain functions such as learning and memory. Disinhibition, defined as a transient brake on inhibition that favors excitation, recently appeared to be a conserved circuit mechanism implicated in various functions such as sensory processing, learning and memory. Although vasoactive intestinal polypeptide (VIP) interneurons are considered to be the main disinhibitory cells, recent studies highlighted a pivotal role of somatostatin (SOM) interneurons in inhibiting GABAergic interneurons and promoting principal cell activation. Interestingly, long-term potentiation of excitatory input synapses onto hippocampal SOM interneurons is proposed as a lasting mechanism for regulation of disinhibition of principal neurons. Such regulation of network metaplasticity may be important for hippocampal-dependent learning and memory. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Evaluation of somatostatin receptors in large cell pulmonary neuroendocrine carcinoma with 99mTc-EDDA/HYNIC-TOC scintigraphy.

    Science.gov (United States)

    Nocuń, Anna; Chrapko, Beata; Gołębiewska, Renata; Stefaniak, Bogusław; Czekajska-Chehab, Elżbieta

    2011-06-01

    Large cell pulmonary neuroendocrine carcinoma (LCNEC) is a poorly differentiated and high-grade neoplasm. It is positioned between an atypical carcinoid and small cell neuroendocrine carcinoma of the lung in a distinct family of pulmonary neuroendocrine tumors. The aim of our study was to detect somatostatin receptors in this uncommon malignancy and to evaluate the sensitivity of somatostatin receptor scintigraphy (SRS) in LCNEC staging. We analyzed data of 26 patients (mean age: 61.5±7.9 years) with histologically confirmed diagnosis of LCNEC, including 18 cases not treated surgically and eight patients after the resection of the primary tumor. SRS was carried out with technetium-99m ethylene diamine-diacetic acid/hydrazinonicotinyl-Tyr3-octreotide (Tc-TOC). A visual analysis of scintigraphic images was done with reference to conventional imaging modalities (computed tomography and bone sicintigraphy). SRS sensitivity for the detection of primary lesions, supradiaphragmatic metastases, and infradiaphragmatic metastases was 100, 83.3%, and 0%, respectively. Five out of 13 metastases to the liver appeared on SRS as photopenic foci, visible on the background of physiological hepatic activity. Only one of the nine metastases to the skeletal system was found by SRS with sensitivity as low as 11.1%. The overall SRS sensitivity for the detection of secondary lesions and of all lesions was 54.8 and 62.2%, respectively. Within a rather large series of LCNEC, the primary tumor showed an uptake of Tc-TOC in all cases, whereas some metastases did show Tc-TOC uptake and some others did not.

  2. Retrospective analysis of dose delivery in intra-operative high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Oh, M.; Avadhani, J.S.; Malhotra, H.K.; Cunningham, B.; Tripp, P.; Jaggernauth, W.; Podgorsak, M.B.

    2007-01-01

    Background. This study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in intra-operative high dose rate (IOHDR) brachytherapy. Methods. Treatment plans of 10 patients previously treated in our facility, which had irregular shapes of treated areas, were used. Treatment geometries reflecting each clinical case were simulated using a phantom assembly with no added build-up on top of the applicator. The treatment planning geometry (full scatter surrounding the applicator) was subsequently simulated for each case by adding bolus on top of the applicator. Results. For geometries representing the clinical IOHDR incomplete scatter environment, measured doses at the 5 mm and 10 mm prescription depths were lower than the corresponding prescribed doses by about 7.7% and 11.1%, respectively. Also, for the two prescription methods, an analysis of the measured dose distributions and their corresponding treatment plans showed average decreases of 1.2 mm and 2.2 mm in depth of prescription dose, respectively. Conclusions. Dosimetric calculations with the assumption of an infinite scatter environment around the applicator and target volume have shown to result in dose delivery errors that significantly decrease the prescription depth for IOHDR treatment.(author)

  3. Fertility of Tall Girls Treated with High-Dose Estrogen, a Dose-Response Relationship

    NARCIS (Netherlands)

    Hendriks, A. E. J.; Drop, S. L. S.; Laven, J. S. E.; Boot, A. M.

    Context: High-dose estrogen treatment to reduce final height of tall girls increases their risk for infertility in later life. Objective: The aim was to study the effect of estrogen dose on fertility outcome of these women. Design/Setting: We conducted a retrospective cohort study of university

  4. Gastrin (G) cells and somatostatin (D) cells in patients with dyspeptic symptoms: Helicobacter pylori associated and non-associated gastritis

    NARCIS (Netherlands)

    Liu, Y.; Vosmaer, G. D. C.; Tytgat, G. N. J.; Xiao, S.-D.; ten Kate, F. J. W.

    2005-01-01

    Background: Gastrin G cells and somatostatin D cells are important regulators of gastric acid secretion and alterations in their relative numbers may play a key role in gastroduodenal disease. Aim: To investigate the effect of Helicobacter pylori infection on the density of immunoreactive G and D

  5. The somatostatin receptor-targeted radiotherapeutic [{sup 90}Y-DOTA-dPhe{sup 1},Tyr{sup 3}]octreotide ({sup 90}Y-SMT 487) eradicates experimental rat pancreatic CA 20948 tumours

    Energy Technology Data Exchange (ETDEWEB)

    Stolz, B.; Weckbecker, G.; Smith-Jones, P.M.; Albert, R.; Raulf, F.; Bruns, C. [Novartis Pharma AG, Basel (Switzerland)

    1998-07-01

    Somatostatin receptor-expressing tumours are potential targets for therapy with radiolabelled somatostatin analogues. We have synthesized a number of such analogues in the past and identified [DOTA-dPhe{sup 1}, Tyr{sup 3}]octreotide (SMT 487) as the most promising candidate molecule because of its advantageous properties in cellular and in vivo tumour models. In the current paper we describe the radiotherapeutic effect of yttrium-90 labelled SMT 487 in Lewis rats bearing the somatostatin receptor-positive rat pancreatic tumour CA 20948. SMT 487 binds with nanomolar affinity to both the human and the rat somatostatin receptor subtype 2 (sst{sub 2}) (human sst{sub 2} IC{sub 50}=0.9 nM, rat sst{sub 2} IC{sub 50}=0.5 nM). In vivo, {sup 90}Y-SMT 487 distributed rapidly to the sst{sub 2} expressing CA 20948 rat pancreatic tumour, with a tumour-to-blood ratio of 49.15 at 24 h post injection. A single intravenous administration of 10 mCi/kg {sup 90}Y-SMT 487 resulted in a complete remission of the tumours in five out of seven CA 20948 tumour-bearing Lewis rats. No regrowth of the tumours occurred 8 months post injection. Control animals that were treated with 30 {mu}g/kg of unlabelled SMT 487 had to be sacrificed 10 days post injection due to excessive growth or necrotic areas on the tumour surface. Upon re-inoculation of tumour cells into those rats that had shown complete remission, the tumours disappeared after 3-4 weeks of moderate growth without any further treatment. The present study shows for the first time the curative potential of {sup 90}Y-SMT 487-based radiotherapy for somatostatin receptor-expressing tumours. Clinical phase I studies with yttrium-labelled SMT 487 have started in September 1997. (orig.) With 4 figs., 2 tabs., 29 refs.

  6. In vivo binding of [{sup 68}Ga]-DOTATOC to somatostatin receptors in neuroendocrine tumours - impact of peptide mass

    Energy Technology Data Exchange (ETDEWEB)

    Velikyan, Irina [Department of Biochemistry and Organic Chemistry, BMC, Uppsala University, Box 599, SE-751 24 Uppsala (Sweden); Uppsala Applied Science Lab, GEMS PET Systems, GE Healthcare, SE-752 28 Uppsala (Sweden); Sundin, Anders [Department of Radiology, Karolinska University Hospital, SE-171 76 Stockholm (Sweden); Eriksson, Barbro [Department of Endocrine Oncology, Uppsala University Hospital, SE-751 85 Uppsala (Sweden); Lundqvist, Hans [Department of Oncology, Radiology and Clinical Immunology, Uppsala University, SE-751 85 Uppsala (Sweden); Soerensen, Jens [Department of Medicinal Sciences, Clinical Physiology and Nuclear Medicine, Uppsala University Hospital, SE-751 85 Uppsala (Sweden); Bergstroem, Mats [Department of Pharmaceutical Biosciences, Uppsala Biomedical Centre, Uppsala University, Uppsala (Sweden); Langstroem, Bengt [Department of Biochemistry and Organic Chemistry, BMC, Uppsala University, Box 599, SE-751 24 Uppsala (Sweden)], E-mail: langstrom@biorg.uu.se

    2010-04-15

    Objectives: The aim of this pilot study was to explore the impact of peptide mass on binding of [{sup 68}Ga]-DOTATOC to neuroendocrine tumour somatostatin receptors in vivo using a tracer of variable specific radioactivity (SRA) and to show the logistic feasibility of sequential PET scans in the same patient. Material and Methods: Nine patients with gastroenteropancreatic neuroendocrine tumours were included. Six of them underwent three sequential PET-CT examinations with intravenous injections of [{sup 68}Ga]-DOTATOC proceeded by 0, 50 and 250 or 500 {mu}g of octreotide, administered 10 min before the tracer. Three patients were examined by dynamic and static PET/CT for pharmacokinetic and dosimetric calculations. The [{sup 68}Ga]-DOTATOC synthesis included preconcentration and purification of the generator eluate and microwave heating in a semi-automated in-house procedure. Results: [{sup 68}Ga]-DOTATOC synthesis and quality control were accomplished within 30 min and radiochemical purity was >95%. The tracer accumulation in the tumours varied and depended on the total amount of the administered peptide. In five of six patients, the highest tumour-to-normal tissue ratio was found when 50 {mu}g of octreotide was preadministered. One patient showed a continuously increasing tumour uptake. Dosimetrically, a large variation in organ doses was found (kidney: 0.086-0.168 mSv/MBq; liver: 0.026-0.096 mSv/MBq; spleen: 0.046-0.226 mSv/MBq). The effective dose (0.015, 0.0067 and 0.0042 mSv/MBq) was correlated to the total amount of decays. Discussion: Three sequential PET-CT examinations using {sup 68}Ga-based tracer was carried out in 1 day. The use of high SRA [{sup 68}Ga]-DOTATOC and unlabelled octreotide indicates an optimal mass leading to better image contrast. [{sup 68}Ga]-DOTATOC-PET-CT employing variable SRA may be utilised for accurate quantification of tumour uptake with subsequent dosimetry for personalized therapy management.

  7. Somatostatin receptor scintigraphy in patients with rheumatoid arthritis and secondary Sjögren's syndrome treated with Infliximab: a pilot study.

    Science.gov (United States)

    Anzola-Fuentes, L K; Chianelli, M; Galli, F; Glaudemans, A W J M; Martin Martin, L; Todino, V; Migliore, A; Signore, A

    2016-12-01

    Human T lymphocytes infiltrating tissues in autoimmune diseases are known to express somatostatin receptors amongst other activation markers. In this study, we evaluated whether somatostatin receptor scintigraphy (SRS) using a radiolabelled somatostatin analogue ((99m)Tc-EDDA/tricine-HYNIC-tyr(3)-octreotide ((99m)Tc-EDDA/HYNIC-TOC)) is able to detect the presence of immune-mediated processes in patients with rheumatoid arthritis and secondary Sjögren's syndrome. We also aimed to evaluate whether positivity to SRS was predictive of therapeutic response and if SRS could be used for monitoring the efficacy of immunomodulatory treatment. Eighteen patients with rheumatoid arthritis and secondary Sjögren's syndrome not responding to conventional treatment were recruited for treatment with infliximab, a monoclonal antibody against TNF-α. All patients had complete blood cell count, renal and liver function tests, measurements of ESR, CRP, ANA, ENA, and anti-dsDNA antibodies, functional salivary gland scintigraphy, labial biopsy, and ophthalmologic assessment with Schirmer's test and tear film break-up time (BUT). Diagnosis was made according to the revised criteria of the American-European Consensus Group. All patients underwent SRS at baseline and after 3-6 months of therapy with infliximab. Eleven out of 18 had repeat SRS images. Images of the salivary glands and major joints were acquired 3 h after injection of 370 MBq of (99m)Tc-EDDA/HYNIC-TOC. Image analysis was performed semi-quantitatively. All patients showed uptake of (99m)Tc-EDDA/HYNIC-TOC in the joints. Salivary glands also showed variable radiopharmaceutical uptake in 12 out of 18 patients, but all patients showed presence of lymphocytic infiltration at labial salivary gland biopsy. All patients, who repeated the study after treatment, showed significant reduction of somatostatin uptake in the joints but not in the salivary glands. SRS using (99m)Tc-EDDA/HYNIC-TOC may be a useful imaging tool to assess

  8. Radiation effects of high and low doses

    International Nuclear Information System (INIS)

    El-Naggar, A.M.

    1998-01-01

    The extensive proliferation of the uses and applications of atomic and nuclear energy resulted in possible repercussions on human health. The prominent features of the health hazards that may be incurred after exposure to high and low radiation doses are discussed. The physical and biological factors involved in the sequential development of radiation health effects and the different cellular responses to radiation injury are considered. The main criteria and features of radiation effects of high and low doses are comprehensively outlined

  9. High daily doses of benzodiazepines among Quebec seniors: prevalence and correlates

    Directory of Open Access Journals (Sweden)

    Moride Yola

    2001-11-01

    Full Text Available Abstract Background Use of high daily doses of benzodiazepines is generally contraindicated for seniors. While both patient and physician factors may influence the use of high daily doses, previous research on the effect of patient factors has been extremely limited. The objectives of this study were to determine the one year prevalence of use of high daily doses of benzodiazepines, and examine physician and patient correlates of such use among Quebec community-dwelling seniors. Methods Patient information for 1423 community-dwelling Quebec seniors who participated in the Canadian Study of Health and Aging was linked to provincial health insurance administrative data bases containing detailed information on prescriptions received and prescribers. Results The standardized one year period prevalence of use of high daily doses of benzodiazepines was 7.9%. Use of high daily doses was more frequent among younger seniors and those who had reported anxiety during the previous year. Patients without cognitive impairment were more likely to receive high dose prescriptions from general practitioners, while those with cognitive impairment were more likely to receive high dose prescriptions from specialists. Conclusion High dose prescribing appears to be related to both patient and physician factors.

  10. Proximity correction of high-dosed frame with PROXECCO

    Science.gov (United States)

    Eisenmann, Hans; Waas, Thomas; Hartmann, Hans

    1994-05-01

    Usefulness of electron beam lithography is strongly related to the efficiency and quality of methods used for proximity correction. This paper addresses the above issue by proposing an extension to the new proximity correction program PROXECCO. The combination of a framing step with PROXECCO produces a pattern with a very high edge accuracy and still allows usage of the fast correction procedure. Making a frame with a higher dose imitates a fine resolution correction where the coarse part is disregarded. So after handling the high resolution effect by means of framing, an additional coarse correction is still needed. Higher doses have a higher contribution to the proximity effect. This additional proximity effect is taken into account with the help of the multi-dose input of PROXECCO. The dose of the frame is variable, depending on the deposited energy coming from backscattering of the proximity. Simulation proves the very high edge accuracy of the applied method.

  11. High-dose buprenorphine: perioperative precautions and management strategies.

    Science.gov (United States)

    Roberts, D M; Meyer-Witting, M

    2005-02-01

    Buprenorphine has been in clinical use in anaesthesia for several decades. Recently, the high-dose sublingual formulation (Subutex, Reckitt Benckiser, Slough, U.K.) has been increasingly used as maintenance therapy in opioid dependence, as an alternative to methadone and other pharmacological therapies. Buprenorphine has unique pharmacological properties making it well suited for use as a maintenance therapy in opioid dependence. However, these same properties may cause difficulty in the perioperative management of pain. Buprenorphine is a partial opioid agonist, attenuating the effects of supplemental illicit or therapeutic opioid agonists. As a result of its high receptor affinity, supplemental opioids do not readily displace buprenorphine from the opioid receptor in standard doses. High-dose buprenorphine has an extended duration of action that prolongs both of these effects. The perioperative management of patients stabilized on high-dose buprenorphine and undergoing surgery requires consideration of the likely analgesic requirements. Where possible the buprenorphine should be continued. Pain management should focus on maximizing non-opioid analgesia, local anaesthesia and non-pharmacological techniques. Where pain may not be adequately relieved by these methods, the addition of a full opioid agonist such as fentanyl or morphine at appropriate doses should be considered, accompanied by close monitoring in a high dependency unit. In situations where this regimen is unlikely to be effective, preoperative conversion to morphine or methadone may be an option. Where available, liaison with a hospital-based alcohol and drug service should always be considered.

  12. Impact of catheter reconstruction error on dose distribution in high dose rate intracavitary brachytherapy and evaluation of OAR doses

    International Nuclear Information System (INIS)

    Thaper, Deepak; Shukla, Arvind; Rathore, Narendra; Oinam, Arun S.

    2016-01-01

    In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this study is to evaluate the impact of catheter reconstruction error on dose distribution in CT based intracavitary brachytherapy planning and evaluation of its effect on organ at risk (OAR) like bladder, rectum and sigmoid and target volume High risk clinical target volume (HR-CTV)

  13. 99mTc-EDDA/HYNIC-TOC in management of patients with head and neck somatostatin receptor positive tumors.

    Science.gov (United States)

    Trogrlic, Mate; Tezak, Stanko

    2016-01-01

    Aim of this study was to determine the value of technetium-99m-hydrazinonicotinyl-Tyr3-octreotide (99mTc-ED-DA/HYNIC-TOC) in patients with somatostatin receptor (SSR) positive tumors of head and neck region. A total number of 16 patients were enrolled in this study. Planar whole body (WB) and single photon emission computed tomography (SPECT) images were acquired at 2 and 4 hours after the injection of approximately 670 MBq of 99mTc-EDDA/HYNIC-TOC. Additional single photon emission computed tomography/computed tomography (SPECT/CT) images of the head and neck region were acquired at 4h post tracer injection. Clinical and imaging follow up were taken as the reference standard. There were 10 female and 6 male patients of age 57.7 ± 12.9 years (58.5; 32-78) years. 99mTc-EDDA/HYNIC-TOC somatostatin receptor scintigraphy (SRS) was TP in 13 patients, TN in two and FP in one. Follow up period for SRS was 31.1 ± 19.4 (29; 2-63) months. 99mTc-EDDA/HYNIC-TOC scintigraphy provided additional information in 50% of patients, with impact on patient management in the same percentage of patients. Distant metastases were found in nine out of 16 patients (56%). 99mTc-EDDA/HYNIC-TOC SRS had sensitivity of 100% (75.3-100%), specificity of 66.7% (9.4-99.2%), accuracy of 93.7%, positive predictive value of 92.9% (66.1-99.8%), and negative predictive value of 100% (15.8-100%). Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC is very useful imaging method in the evalu-ation of patients with SSR positive tumors of head and neck region.

  14. Somatostatin-14-like antigenic sites in fixed islet D-cells are unaltered by cysteamine: a quantitative electron microscopic immunocytochemical evaluation

    International Nuclear Information System (INIS)

    Patel, Y.C.; Ravazzola, M.; Amherdt, M.; Orci, L.

    1987-01-01

    Exposure of somatostatin cells to cysteamine (CSH) produces a marked reduction in somatostatin-14-like immunoreactivity (S-14 LI) in cell extracts. In the present study we have evaluated the effects of CSH on S-14-like sites in fixed islet D-cells using immunofluorescence and quantitative electron microscopic immunocytochemistry. Monolayer cultures of rat islet cells exposed to CSH (10 mM) for 1 h and subsequently extracted in 1 M acetic acid exhibited a severe reduction in S-14 LI from 6.6 +/- 0.48 to 0.7 +/- 0.06 ng/dish. CSH-induced reduction in S-14 LI persisted when cells were fixed in Zamboni's solution for 16 h and subsequently extracted and assayed. By immunofluorescence, however, the relative numbers of somatostatin-positive cells as well as the fluorescent intensity were identical in control and CSH-treated cells. CSH did not produce any identifiable abnormality in the ultrastructural appearance of D-cells. Protein A-gold labeling of the islet cells showed a uniform distribution of gold particles in both control and CSH-treated cultures. The density of gold particles over D-cell secretory granules from CSH-exposed cultures (36.6 +/- 3.5 particles/micron2) was not different from that in control D-cell granules (42.2 +/- 5.9 particles/micron2). These data clearly indicate that despite a profound reduction by CSH of S-14 LI in tissue extracts, there is no detectable decrease in the same antigenic sites in tissue sections when assessed immunocytochemically

  15. High-temperature absorbed dose measurements in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.; Ardonceau, J.; Zuppiroli, L.

    1988-01-01

    Organic conductors of the tetraselenotetracene family have been tested as ''high-temperature'' absorbed dose dosimeters. They were heated up to 120 0 C and irradiated at this temperature with 1-MeV electrons in order to simulate, in a short time, a much longer γ-ray irradiation. The electric resistance increase of the crystal can be considered a good measurement of the absorbed dose in the range 10 6 Gy to a few 10 8 Gy and presumably one order of magnitude more. This dosimeter also permits on-line (in-situ) measurements of the absorbed dose without removing the sensor from the irradiation site. The respective advantages of organic and inorganic dosimeters at these temperature and dose ranges are also discussed. In this connection, we outline new, but negative, results concerning the possible use of silica as a high-temperature, high-dose dosimeter. (author)

  16. High-dose MeV electron irradiation of Si-SiO2 structures implanted with high doses Si+

    Science.gov (United States)

    Kaschieva, S.; Angelov, Ch; Dmitriev, S. N.

    2018-03-01

    The influence was studied of 22-MeV electron irradiation on Si-SiO2 structures implanted with high-fluence Si+ ions. Our earlier works demonstrated that Si redistribution is observed in Si+-ion-implanted Si-SiO2 structures (after MeV electron irradiation) only in the case when ion implantation is carried out with a higher fluence (1016 cm-2). We focused our attention on the interaction of high-dose MeV electron irradiation (6.0×1016 cm-2) with n-Si-SiO2 structures implanted with Si+ ions (fluence 5.4×1016 cm-2 of the same order magnitude). The redistribution of both oxygen and silicon atoms in the implanted Si-SiO2 samples after MeV electron irradiation was studied by Rutherford back-scattering (RBS) spectroscopy in combination with a channeling technique (RBS/C). Our results demonstrated that the redistribution of oxygen and silicon atoms in the implanted samples reaches saturation after these high doses of MeV electron irradiation. The transformation of amorphous SiO2 surface into crystalline Si nanostructures (after MeV electron irradiation) was evidenced by atomic force microscopy (AFM). Silicon nanocrystals are formed on the SiO2 surface after MeV electron irradiation. The shape and number of the Si nanocrystals on the SiO2 surface depend on the MeV electron irradiation, while their size increases with the dose. The mean Si nanocrystals height is 16-20 nm after irradiation with MeV electrons at the dose of 6.0×1016 cm-2.

  17. A novel theory of radiation damage at high doses

    International Nuclear Information System (INIS)

    Seeger, A.; Stuttgart Univ.

    1989-01-01

    Deviations of radiation damage (in the case of metals usually monitored by the residual electrical resistivity) from proportionality with the irradiation dose have so far been analysed almost exclusively in terms of extensions of models originally developed for small doses. The present theory considers the opposite limit i.e. the quasi-saturated state. It is argued that at high doses the Lueck-Sizmann effect may result in a self-organization of clusters of vacancies and self-interstitials, forming a heterogeneous froth. Possible structures of this froth and its effect on the electrical resistivity of metals are discussed. The model is shown to account for the dependence of the ''saturation resistivity'' on the nature of the irradiation as well as for several other hitherto poorly explained observations. Among them are the electrical-resistivity variation induced by high-dose irradiation with heavy ions, the amorphization of certain alloys by high-dose electron irradiation, and the occurrence of ordered arrays of stacking-fault tetrahedra after in-situ irradiations in high-voltage electron microscopes. (author)

  18. Radiobiological aspects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation

    International Nuclear Information System (INIS)

    Turesson, I.

    1990-01-01

    The biological effects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation in interstitial and intracavitary radiotherapy and total body irradiation are discussed in terms of dose-rate fractionation sensitivity for various tissues. A scaling between dose-rate and fraction size was established for acute and late normal-tissue effects which can serve as a guideline for local treatment in the range of dose rates between 0.02 and 0.005 Gy/min and fraction sizes between 8.5 and 2.5 Gy. This is valid provided cell-cycle progression and proliferation can be ignored. Assuming that the acute and late tissue responses are characterized by α/β values of about 10 and 3 Gy and a mono-exponential repair half-time of about 3 h, the same total doses given with either of the two methods are approximately equivalent. The equivalence for acute and late non-hemopoietic normal tissue damage is 0.02 Gy/min and 8.5 Gy per fraction; 0.01 Gy/min and 5.5 Gy per fraction; and 0.005 Gy/min and 2.5Gy per fraction. A very low dose rate, below 0.005 Gy/min, is thus necessary to simulate high dose-rate radiotherapy with fraction sizes of about 2Gy. The scaling factor is, however, dependent on the repair half-time of the tissue. A review of published data on dose-rate effects for normal tissue response showed a significantly stronger dose-rate dependence for late than for acute effects below 0.02 Gy/min. There was no significant difference in dose-rate dependence between various acute non-hemopoietic effects or between various late effects. The consistent dose-rate dependence, which justifies the use of a general scaling factor between fraction size and dose rate, contrasts with the wide range of values for repair half-time calculated for various normal-tissue effects. This indicates that the model currently used for repair kinetics is not satisfactory. There are also few experimental data in the clinical dose-rate range, below 0.02 Gy/min. It is therefore

  19. Statistical behavior of high doses in medical radiodiagnosis; Comportamento estatistico das altas doses em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana Elisa, E-mail: adrianaebarboza@gmail.com, E-mail: elisa@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  20. Effects of low priming dose irradiation on cell cycle arrest of HepG2 cells caused by high dose irradiation

    International Nuclear Information System (INIS)

    Xia Jingguang; Jin Xiaodong; Chinese Academy of Sciences, Beijing; Li Wenjian; Wang Jufang; Guo Chuanling; Gao Qingxiang

    2005-01-01

    Human hepatoma cells hepG2 were irradiated twice by 60 Co γ-rays with a priming dose of 5 cGy and a higher dose of 3 Gy performed 4h or 8h after the low dose irradiation. Effects of the priming dose irradiation on cell cycle arrest caused by high dose were examined with flow cytometry. Cells in G 2 /M phase accumulated temporarily after the 5 cGy irradiation, and proliferation of tumor cells was promoted significantly by the low dose irradiation. After the 3 Gy irradiation, G 2 phase arrest occurred, and S phase delayed temporally. In comparison with 3 kGy irradiation only, the priming dose delivered 4h prior to the high dose irradiation facilitated accumulation of hepG2 cells in G 2 /M phase, whereas the priming dose delivered 8h prior to the high dose irradiation helped the cells to overcome G 2 arrest. It was concluded that effects of the priming dose treatment on cell cycle arrest caused by high dose irradiation were dependent on time interval between the two irradiations. (authors)

  1. A clinical comparison of high dose and low dose of Suxamethonium

    Directory of Open Access Journals (Sweden)

    RK Yadav

    2014-01-01

    Full Text Available Background: Suxamethonium having its rapid onset and short duration of action makes this drug unique amongst the neuromuscular blocking drugs described so far. However, use of suxamethonium is associated with a large number of undesirable side effects. Objective: To evaluate clinical effects of high and low dose of suxamethonium and to determine whether lower dose of suxamethonium can be used for any beneficial effects in terms of its various adverse effects e.g. cardiovascular responses, post-operative muscle pains and intraocular pressure. Methods: A total of 100 patients were included in this prospective study. All these patients on preoperative clinical evaluation were assessed to have adequate airway. All the patients were divided in two groups, low dose group (group I and High dose group (group II with 50 patients in each at random. A standard anesthetic technique was adhered to all the patients and following parameters were observed on comparative basis: a. Fasciculation and post operative myalgia. b. Cardiovascular effects, c. Intraocular pressure. Observation: The incidence of post Suxamethonium pain was significantly greater in group II. Increase in heart rate from baseline was significant in both groups. There was no significant difference between the two groups in the diastolic pressure but rise in systolic blood pressure was significant at all assessment times in both groups. This rise from control was statistically significant. Conclusion: Suxamethonium can be used in lower doses (0.5 mg/kg in elective cases without airway compromise. It gives benefits of reduced muscle pains, cardiovascular responses and intraocular hypertension. Journal of College of Medical Sciences-Nepal, 2013, Vol-9, No-2, 1-8 DOI: http://dx.doi.org/10.3126/jcmsn.v9i2.9677

  2. Studies in rats on octreotide labelled with Ga-67: A potential radiopharmaceutical agent for the treatment of somatostatin receptor-positive tumours

    International Nuclear Information System (INIS)

    Lazniekova, A.; Laznieek, M.; Trejtnar, F.; Maecke, H.R.

    2001-01-01

    The paper presents the preparation, biodistribution and analysis of elimination mechanisms of 67 Ga-[DFO]-octreotide in rats. For labelling of the ligand with 67 Ga, desferrioxamine B (DFO) coupled to octreotide via the succinyl linker has been shown to form a stable chelating agent for binding of 67 Ga. The radiopharmaceutical was prepared by direct chelating of 67 Ga 3+ with [DFO]-octreotide in a slightly acidic reaction medium with high radiochemical purity. Pharmacokinetics of 67 Ga-[DFO]-octreotide of radioactivity in rats has shown relatively rapid elimination of the compound from the body with a long-term retention in the kidney and organs with high somatostatin receptor density. The agent was eliminated mostly by urine predominantly by the mechanism of glomerular filtration. (author)

  3. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline

    DEFF Research Database (Denmark)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören

    2004-01-01

    OBJECTIVES: To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. METHODS: Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxi...

  4. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  5. The role of somatostatin in GLP-1-induced inhibition of glucagon secretion in mice

    DEFF Research Database (Denmark)

    Ørgaard, Anne; Holst, Jens J

    2017-01-01

    AIMS/HYPOTHESIS: Glucagon-like peptide-1 (GLP-1) receptor agonists are currently used for the treatment of type 2 diabetes. Their main mechanism of action is enhancement of glucose-induced insulin secretion (from increased beta cell glucose sensitivity) and inhibition of glucagon secretion...... on glucagon secretion is heavily debated. Glucagon inhibition is also said to be glucose-dependent, although it is unclear what is meant by this. We hypothesise here that GLP-1 does not inhibit glucagon secretion during hypoglycaemia because the inhibition depends on somatostatin secretion, which in turn...

  6. Accelerated Irradiations for High Dose Microstructures in Fast Reactor Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zhijie [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-03-31

    The objective of this project is to determine the extent to which high dose rate, self-ion irradiation can be used as an accelerated irradiation tool to understand microstructure evolution at high doses and temperatures relevant to advanced fast reactors. We will accomplish the goal by evaluating phase stability and swelling of F-M alloys relevant to SFR systems at very high dose by combining experiment and modeling in an effort to obtain a quantitative description of the processes at high and low damage rates.

  7. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    International Nuclear Information System (INIS)

    Sakamoto, Yukio

    2005-01-01

    Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of these data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality factors to consider the consistency between radiation weighting factors and Q-L relationship. The effective dose conversion coefficients obtained in this work were in good agreement with those recently evaluated by using FLUKA code for photons and electrons with all energies, and neutrons and protons below 500 MeV. There were some discrepancy between two data owing to the difference of cross sections in the nuclear reaction models. The dose conversion coefficients of effective dose equivalents for high energy radiations based on Q-L relation in ICRP Publication 60 were evaluated only in this work. The previous comparison between effective dose and effective dose equivalent made it clear that the radiation weighting factors for high energy neutrons and protons were overestimated and the modification was required. (author)

  8. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  9. Neuroprotective potential of high-dose biotin.

    Science.gov (United States)

    McCarty, Mark F; DiNicolantonio, James J

    2017-11-01

    A recent controlled trial has established that high-dose biotin supplementation - 100 mg, three times daily - has a stabilizing effect on progression of multiple sclerosis (MS). Although this effect has been attributed to an optimization of biotin's essential cofactor role in the brain, a case can be made that direct stimulation of soluble guanylate cyclase (sGC) by pharmacological concentrations of biotin plays a key role in this regard. The utility of high-dose biotin in MS might reflect an anti-inflammatory effect of cGMP on the cerebral microvasculature, as well on oligodendrocyte differentiation and on Schwann cell production of neurotrophic factors thought to have potential for managing MS. But biotin's ability to boost cGMP synthesis in the brain may have broader neuroprotective potential. In many types of neurons and neural cells, cGMP exerts neurotrophic-mimetic effects - entailing activation of the PI3K-Akt and Ras-ERK pathways - that promote neuron survival and plasticity. Hippocampal long term potentiation requires nitric oxide synthesis, which in turn promotes an activating phosphorylation of CREB via a pathway involving cGMP and protein kinase G (PKG). In Alzheimer's disease (AD), amyloid beta suppresses this mechanism by inhibiting sGC activity; agents which exert a countervailing effect by boosting cGMP levels tend to restore effective long-term potentiation in rodent models of AD. Moreover, NO/cGMP suppresses amyloid beta production within the brain by inhibiting expression of amyloid precursor protein and BACE1. In conjunction with cGMP's ability to oppose neuron apoptosis, these effects suggest that high-dose biotin might have potential for the prevention and management of AD. cGMP also promotes neurogenesis, and may lessen stroke risk by impeding atherogenesis and hypertrophic remodeling in the cerebral vasculature. The neuroprotective potential of high-dose biotin likely could be boosted by concurrent administration of brain

  10. In vivo detection of somatostatin receptors in patients with functionless pituitary adenomas by means of a radioiodinated analog of somatostatin ((123I)SDZ 204-090)

    Energy Technology Data Exchange (ETDEWEB)

    Faglia, G.; Bazzoni, N.; Spada, A.; Arosio, M.; Ambrosi, B.; Spinelli, F.; Sara, R.; Bonino, C.; Lunghi, F. (Institute of Endocrine Sciences, University of Milan, Ospedale Maggiore IRCCS (Italy))

    1991-10-01

    The recent availability of a Tyr3-substituted octreotide (SDZ 204-090) for radioiodination has allowed somatostatin (SRIH) receptor binding to be studied in vivo, and receptor-positive tumors of different origins to be visualized with a gamma-camera. This prompted us to investigate whether this compound could be used for external imaging of functionless pituitary adenomas displaying SRIH receptors. Eight patients with functionless pituitary adenomas, three patients with acromegaly, and three with macroprolactinoma were injected iv with 123I-labeled Tyr3-octreotide and then scanned with a gamma-camera. Positive scans were obtained in the three acromegalics and in two of the eight patients with functionless pituitary tumors. The patients with macroprolactinoma had negative scans. The diagnosis of functionless pituitary adenomas was confirmed by light and electron microscopic examination as well as immunocytochemical studies. In vitro binding of (125I)Tyr11-SRIH to cell membranes was evaluated in four functionless and three GH-secreting adenomas removed from seven of the patients. All of the GH-secreting as well as one of the four functionless adenomas had high affinity SRIH-binding sites, without differences in number or affinity, whereas SRIH-binding sites were not detected in the others. Positive scans were observed only in patients bearing tumors with high affinity SRIH-binding sites. In conclusion, (123I)Tyr3-octreotide appears to be a promising tool for singling out, in vivo, patients with functionless pituitary tumors displaying SRIH receptors who might potentially benefit from octreotide treatment.

  11. Novel sst2-selective somatostatin agonists. Three-dimensional consensus structure by NMR

    Science.gov (United States)

    Grace, Christy Rani R.; Erchegyi, Judit; Koerber, Steven C.; Reubi, Jean Claude; Rivier, Jean; Riek, Roland

    2008-01-01

    The three-dimensional NMR structures of six octapeptide agonist analogues of somatostatin (SRIF) in the free form are described. These analogues, with the basic sequence H-DPhe/Phe2-c[Cys3-Xxx7-DTrp8-Lys9-Thr10-Cys14]-Thr-NH2 (the numbering refers to the position in native SRIF), with Xxx7 being Ala/Aph, exhibit potent and highly selective binding to human SRIF type 2 (sst2) receptors. The backbone of these sst2-selective analogues have the usual type-II’ β-turn reported in the literature for sst2/3/5-subtype-selective analogues. Correlating biological results and NMR studies led to the identification of the side chains of DPhe2, DTrp8 and Lys9 as the necessary components of the sst2 pharmacophore. This is the first study to show that the aromatic ring at position 7 (Phe7) is not critical for sst2 binding and that it plays an important role in sst3 and sst5 binding. This pharmacophore is therefore different from that proposed by others for sst2/3/5 analogues. PMID:16854054

  12. Somatostatin receptor expression in Merkel cell carcinoma as target for molecular imaging

    International Nuclear Information System (INIS)

    Buder, Kristina; Becker, Jürgen C; Lapa, Constantin; Kreissl, Michael C; Schirbel, Andreas; Herrmann, Ken; Schnack, Alexander; Bröcker, Eva-Bettina; Goebeler, Matthias; Buck, Andreas K

    2014-01-01

    Merkel cell carcinoma (MCC) is a rare cutaneous neoplasm with increasing incidence, aggressive behavior and poor prognosis. Somatostatin receptors (SSTR) are expressed in MCC and represent a potential target for both imaging and treatment. To non-invasively assess SSTR expression in MCC using PET and the radiotracers [ 68 Ga]DOTA-D-Phe 1 -Tyr 3 -octreotide (DOTATOC) or -octreotate (DOTATATE) as surrogate for tumor burden. In 24 patients with histologically proven MCC SSTR-PET was performed and compared to results of computed tomography (CT). SSTR-PET detected primary and metastatic MCC lesions. On a patient-based analysis, sensitivity of SSTR-PET was 73% for nodal metastases, 100% for bone, and 67% for soft-tissue metastases, respectively. Notably, brain metastases were initially detected by SSTR-PET in 2 patients, whereas liver and lung metastases were diagnosed exclusively by CT. SSTR-PET showed concordance to CT results in 20 out of 24 patients. Four patients (17%) were up-staged due to SSTR-PET and patient management was changed in 3 patients (13%). SSTR-PET showed high sensitivity for imaging bone, soft tissue and brain metastases, and particularly in combination with CT had a significant impact on clinical stage and patient management

  13. Polybutadiene and Styrene-Butadiene rubbers for high-dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Lucas N. [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias-IFG,Campus Goiania, Goiania -GO (Brazil); Instituto de Pesquisas Energeticas e Nucleares -IPEN, Sao Paulo-SP (Brazil); Vieira, Silvio L. [Instituto de Fisica, Universidade Federal de Goias-UFG, Campus Samambaia, Goiania-GO (Brazil); Schimidt, Fernando [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias-IFG,Campus Inhumas, Inhumas-GO (Brazil); Antonio, Patricia L.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares -IPEN, Sao Paulo-SP (Brazil)

    2015-07-01

    Polybutadiene and Styrene-Butadiene are synthetical rubbers used widely for pneumatic tires manufacturing. In this research, the dosimeter characteristics of those rubbers were studied for application in high-dose dosimetry. The rubber samples were irradiated with doses of 10 Gy up to 10 kGy, using a {sup 60}Co Gamma Cell-220 system (dose rate of 1.089 kGy/h) and their readings were taken on a Fourier Transform Infrared Spectroscopy-FTIR system (model Frontier/Perkin Elmer). The ratios of two absorbance peaks were taken for each kind of rubber spectrum, Polybutadiene (1306/1130 cm{sup -1}) and Styrene-Butadiene (1449/1306 cm{sup -1}). The ratio calculated was used as the response to the irradiation, and is not uniform across the sample. From the results, it can be concluded for both rubbers: a) the dose-response curves may be useful for high-dose dosimetry (greater than 250 Gy); b) their response for reproducibility presented standard deviations lower than 2.5%; c) the relative sensitivity was higher for Styrene-Butadiene (1.86 kGy{sup -1}) than for Polybutadiene (1.81 kGy{sup -1}), d) for doses of 10 kGy to 200 kGy, there was no variation in the dosimetric response. Both types of rubber samples showed usefulness as high-dose dosimeters. (authors)

  14. Effects of ligand priming and multiple-dose injection on tissue uptake of 111In-pentetreotide in rats

    International Nuclear Information System (INIS)

    Breeman, Wout A. P.; Jong, Marion de; Bernard, Bert F.; Bakker, Willem H.; Rolleman, Edgar J.; Kwekkeboom, Kik J.; Visser, Theo J.; Krenning, Eric P.

    1997-01-01

    In patients undergoing somatostatin receptor scintigraphy, treatment with octreotide (Sandostatin[reg]) is usually discontinued 24-48 h before and after injection with the radioligand 111 In-pentetreotide ([ 111 In-DTPA o ]octreotide) (Octreoscan[reg]) because octreotide competes with radioligand for the same receptors. However, Doerr et al. and Soresi et al. reported improved visualization of carcinoid and small cell lung cancer lesions, respectively, during continued octreotide treatment. We found that intravenous administration of unlabeled octreotide to rats inhibited the binding of an optimal dose (0.5 μg) of 111 In-pentetreotide to somatostatin receptors in pancreas and adrenals in a mass- and time-dependent way. Pretreatment with unlabeled octreotide never increased receptor binding of 111 In-pentetreotide. Administration of 100 μg of octreotide decreased receptor-bound radioactivity if given simultaneously with or 10 or 20 min after injection of the radioligand, but had no effect if given 30 min after the radioligand. These findings indicate rapid processing of receptor-bound octreotide and suggest that octreotide treatment of patients undergoing 111 In-pentetreotide scintigraphy may be reinitiated as soon as 1 h after radioligand administration

  15. Assessments for high dose radionuclide therapy treatment planning

    International Nuclear Information System (INIS)

    Fisher, D.R.

    2003-01-01

    Advances in the biotechnology of cell specific targeting of cancer and the increased number of clinical trials involving treatment of cancer patients with radiolabelled antibodies, peptides, and similar delivery vehicles have led to an increase in the number of high dose radionuclide therapy procedures. Optimised radionuclide therapy for cancer treatment is based on the concept of absorbed dose to the dose limiting normal organ or tissue. The limiting normal tissue is often the red marrow, but it may sometimes be the lungs, liver, intestinal tract, or kidneys. Appropriate treatment planning requires assessment of radiation dose to several internal organs and tissues, and usually involves biodistribution studies in the patient using a tracer amount of radionuclide bound to the targeting agent and imaged at sequential timepoints using a planar gamma camera. Time-activity curves are developed from the imaging data for the major organ tissues of concern, for the whole body and sometimes for selected tumours. Patient specific factors often require that dose estimates be customised for each patient. In the United States, the Food and Drug Administration regulates the experimental use of investigational new drugs and requires 'reasonable calculation of radiation absorbed dose to the whole body and to critical organs' using the methods prescribed by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. Review of high dose studies shows that some are conducted with minimal dosimetry, that the marrow dose is difficult to establish and is subject to large uncertainties. Despite the general availability of software, internal dosimetry methods often seem to be inconsistent from one clinical centre to another. (author)

  16. Central nervous system immunoreactive somatostatin, substance P and met-enkephalin concentrations in experimental hepatic encephalopathy in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Miller, J.L.; Millar, R.P.; Kirsch, R. (Cape Town Univ. (South Africa))

    1982-06-12

    Immunoreactive somatostatin, substance P and met-enkephalin concentrations were measured in various regions of the rat brain 65 hours after portacaval shunt and compared with concentrations in sham-operated animals. No significant difference was detected in any of the three peptides in the regions studied, suggesting that these peptides do not play a role in the pathogenesis of hepatic encephalopathy.

  17. NMDAR hypofunction and somatostatin-expressing GABAergic interneurons and receptors: A newly identified correlation and its effects in schizophrenia

    Directory of Open Access Journals (Sweden)

    Fatemah Alherz

    2017-06-01

    Full Text Available This review investigates the association between N-methyl-d-Aspartate receptor (NMDAR hypofunction and somatostatin-expressing GABAergic interneurons (SST+ and how it contributes to the cognitive deficits observed in schizophrenia (SZ. This is based on evidence that NMDAR antagonists caused symptoms resembling SZ in healthy individuals. NMDAR hypofunction in GABAergic interneurons results in the modulation of the cortical network oscillation, particularly in the gamma range (30–80 Hz. These gamma-band oscillation (GBO abnormalities were found to lead to the cognitive deficits observed in the disorder. Postmortem mRNA studies have shown that SST decreased more significantly than any other biomarker in schizophrenic subjects. The functional role of Somatostatin (SST in the aetiology of SZ can be studied through its receptors. Genetic knockout studies in animal models in Huntington's disease (HD have shown that a specific SST receptor, SSTR2, is increased along with the increased NMDAR activity, with opposing patterns observed in SZ. A direct correlation between SSTR and NMDAR is hence inferred in this review with the hope of finding a potential new therapeutic target for the treatment of SZ and related neurological conditions.

  18. Safety and tolerability of high doses of glucocorticoides

    Directory of Open Access Journals (Sweden)

    Rakić Branislava D.

    2016-01-01

    Full Text Available Introduction: Treatment of acute lymphoblastic leukemia includes the use of high doses of glucocorticoides (prednisone and dexamethasone, which significantly increase the success of therapy due to lymphocytolitic effect. The aim: The aim of the study was to determine tolerability of high doses of prednisone and dexamethasone in children with acute lymphoblastic leukemia and the structure and the intensity of adverse effects, occurred after application of these medicines. Subjects and methods: In a prospective study, we analyzed adverse effects of high doses of glucocorticoides in children suffering acute lymphoblastic leukemia treated in the Institute for Child and Youth Health Care of Vojvodina, since December 2010. until October 2014, were analyzed. This study included 18 patients, aged from 2 to 15 years. Results: Hyperglycemia appeared in 89% of patients treated with prednisone and in 61% of patients treated with dexamethasone. In order to control the high blood glucose level (above 10 mmol /L, in 11% of patients insulin was used. Hypertension appeared in 28% patients treated with prednisone and dexamethasone. Antihypertensives were needed for regulation in 17% patients. Hypopotassemia and hypocalcaemia were significantly more expressed after the use of prednisone in comparison to dexamethasone. In 11% of patients, the treatment with dexamethasone caused depressive behavior, followed by agitation. Conclusion: Adverse effects of dexamethasone and prednisone, administered in high doses in children with ALL were known, expected and reversible. Adverse reactions usually disappeared spontaneously or after short-term symptomatic therapy.

  19. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  20. High-dose secondary calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Humphreys, J.C. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program.

  1. High-dose secondary calibration laboratory accreditation program

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1993-01-01

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program

  2. Relevance of high-dose chemotherapy in solid tumours

    NARCIS (Netherlands)

    Nieboer, P; de Vries, EGE; Mulder, NH; van der Graaf, WTA

    Drug resistance is a major problem in the treatment of solid tumours. Based on a steep dose-response relationship for especially alkylating agents on tumour cell survival, high-dose chemotherapy was considered of interest for the treatment of solid tumours. Results of phase 1 and 2 studies with

  3. High-dose erythropoietin for tissue protection

    DEFF Research Database (Denmark)

    Lund, Anton; Lundby, Carsten; Olsen, Niels Vidiendal

    2014-01-01

    BACKGROUND: The discovery of potential anti-apoptotic and cytoprotective effects of recombinant human erythropoietin (rHuEPO) has led to clinical trials investigating the use of high-dose, short-term rHuEPO therapy for tissue protection in conditions such as stroke and myocardial infarction....... Experimental studies have been favourable, but the clinical efficacy has yet to be validated. MATERIALS AND METHODS: We have reviewed clinical studies regarding the use of high-dose, short-term rHuEPO therapy for tissue protection in humans with the purpose to detail the safety and efficacy of r...... no effect of rHuEPO therapy on measures of tissue protection. Five trials including 1025 patients reported safety concerns in the form of increased mortality or adverse event rates. No studies reported reduced mortality. CONCLUSIONS: Evidence is sparse to support a tissue-protective benefit of r...

  4. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    International Nuclear Information System (INIS)

    Cunha, Elisete L.; Schimitberger, Thiago

    2017-01-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm -1 and 3271 cm -1 , with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  5. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Elisete L.; Schimitberger, Thiago, E-mail: elisete.cunha@cdtn.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Oliveira, Cristiana M.; Faria, Luiz O., E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm{sup -1} and 3271 cm{sup -1}, with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  6. Enhanced bilateral somatostatin receptor expression in mediastinal lymph nodes (''chimney sign'') in occult metastatic medullary thyroid cancer: a typical site of tumour manifestation?

    International Nuclear Information System (INIS)

    Behr, T.M.; Gratz, S.; Markus, P.M.; Dunn, R.M.; Huefner, M.; Becker, H.; Becker, W.

    1997-01-01

    In medullary thyroid cancer (MTC), post-surgically elevated plasma calcitonin and/or carcinoembryonic antigen levels frequently indicate persisting metastatic disease, although conventional diagnostic procedures fail to localize the responsible lesions (occult disease). Somatostatin analogues have been used successfully in disease localization, but recently concerns have been raised that increased thoracic uptake of indium-111 pentetreotide in patients with previous external beam irradiation may represent a false-positive finding, caused by post-irradiation pulmonary fibrosis. We recently examined seven patients with metastatic MTC by somatostatin receptor scintigraphy (six with occult and one with established disease). In four patients, all of whom had stable or slowly rising tumour marker levels over several years, a chimney-like bilateral mediastinal uptake of indium-111 pentetreotide was found. In two patients with persisting hypercalcitonaemia immediately after primary surgery, supraclavicular lymph node metastases were identified as the responsible lesions. None of these seven patients had prior external beam radiation therapy. In two cases, histological confirmation was obtained. In one patient, disease progression could be shown during follow-up. These data suggest that bilateral mediastinal lymph node involvement is a typical site of disease in slowly progressing occult metastatic MTC; the ''chimney sign'' may represent a typical finding with somatostatin analogues in such cases. Therefore, we believe that even in the case of prior external beam irradiation, mediastinal uptake of octreotide might represent metastatic MTC rather than radiation fibrosis. (orig.). With 2 figs., 1 tab

  7. Methodology of high dose research in medical radiodiagnostic; Metodologia de investigacao de doses elevadas em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana E.; Martins, Cintia P. de S., E-mail: ird@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-11-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations.

  8. Quality of life is impaired in association with the need for prolonged postoperative therapy by somatostatin analogs in patients with acromegaly

    NARCIS (Netherlands)

    Postma, Mark R; Netea-Maier, Romana T; van den Berg, Gerrit; Homan, Jens; Sluiter, Wim J; Wagenmakers, Margreet A; van den Bergh, Alfons C M; Wolffenbuttel, Bruce H R; Hermus, Ad R M M; van Beek, André P

    OBJECTIVE: To assess the influence of long-acting somatostatin analogs (SSTA) after initial pituitary surgery on long-term health-related quality of life (HR-QoL) in relation to disease control in patients with acromegaly. DESIGN: This is a cross-sectional study in two tertiary referral centers in

  9. Quality of life is impaired in association with the need for prolonged postoperative therapy by somatostatin analogs in patients with acromegaly.

    NARCIS (Netherlands)

    Postma, M.R.; Netea-Maier, R.T.; Berg, G. van den; Homan, J.; Sluiter, W.J.; Wagenmakers, M.A.E.M.; Bergh, A.C. van den; Wolffenbuttel, B.H.R.; Hermus, A.R.M.M.; Beek, A.P. van

    2012-01-01

    OBJECTIVE: To assess the influence of long-acting somatostatin analogs (SSTA) after initial pituitary surgery on long-term health-related quality of life (HR-QoL) in relation to disease control in patients with acromegaly. DESIGN: This is a cross-sectional study in two tertiary referral centers in

  10. Molecular imaging of neuroendocrine tumors using {sup 68}Ga-labeled peptides (Somatostatin receptor PET/CT); Molekulare Bildgebung neuroendokriner Tumoren mit {sup 68}Ga-markierten Peptiden (Somatostatinrezeptor-PET/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Baum, R.P.; Prasad, V. [Zentralklinik Bad Berka GmbH (Germany). Klinik fuer Nuklearmedizin/PET-Zentrum; Hoersch, D. [Zentralklinik Bad Berka GmbH (Germany). Klinik fuer Innere Medizin, Gastroenterologie, Onkologie, Endokrionologie

    2009-06-15

    Receptor PET/CT using {sup 68}Ga-labeled somatostatin analogues (DOTA-NOC, DOTA-TOC or DOTA-TATE) enables the highly sensitive molecular imaging of neuroendocrine tumors (NETs) based on the expression of somatostatin receptors and even the detection of receptor subtypes. Our experience after more than 3000 studies shows that receptor PET/CT has a significantly higher tumor detection rate than conventional scintigraphy (even in SPECT/CT technique), and that tumor lesions can be very accurately localized. By calculating standardized uptake values (SUV) - which are reproducible and investigator-independent - patients can be selected for peptide receptor radiotherapy and also the course after therapy can be controlled. Receptor-PET/CT is the most sensitive imaging modality for the detection of unknown primary tumors (CUP syndrome), which is especially true for the detection of neuroendocrine tumors of the pancreas and small bowel; whole-body staging (''one stop shop'') as well as restaging and selection of patients for peptide receptor radiotherapy can be performed using a patient-friendly procedure (examination finished within one hour) exposing the patient to less radiation than whole-body CT scanning. The {sup 68}Ge/{sup 68}Ga generator has proved very reliable over the years - even in a hospital environment. The effective costs for {sup 68}Ga labeled somatostatin analogues might be less than for scintigraphic agents, provided a certain number of studies per year are performed. The development of new tumor-specific peptides as well as of other DOTA- or NOTA-coupled radiopharmaceuticals opens a new avenue into the future: finally, the {sup 68}Ga generator could play a similar important role for PET/CT as did the {sup 99m}Tc-Generator for conventional gamma camera imaging over the last decades. (orig.)

  11. Somatostatin-based Radiopeptide Therapy with [177Lu-DOTA]-TOC versus [90Y-DOTA]-TOC in Neuroendocrine Tumors

    OpenAIRE

    Romer A Seiler D Marincek N Brunner P Koller MT Ng QK Maecke HR Muller-Brand J Rochlitz C B

    2014-01-01

    PURPOSE: Somatostatin based radiopeptide treatment is generally performed using the ß emitting radionuclides (90)Y or (177)Lu. The present study aimed at comparing benefits and harms of both therapeutic approaches. METHODS: In a comparative cohort study patients with advanced neuroendocrine tumours underwent repeated cycles of [(90)Y DOTA] TOC or [(177)Lu DOTA] TOC until progression of disease or permanent adverse events. Multivariable Cox regression and competing risks regression were emplo...

  12. An evaluation of high-dose jobs for ALARA improvement

    International Nuclear Information System (INIS)

    Mun, J. H.; Kim, H. S.

    1997-01-01

    It is well known that about 70 percent of occupational dose have incurred from maintenance jobs at outage period. To reduce occupational dose, first, the high-dose jobs at the outage period should be identified and evaluated. For this, the database program is used, which contains the ORE data of reference plants, Kori Units 3 and 4. As a result, it is found that the jobs related to steam generator are the highest dose jobs in terms of collective ORE dose. From the analysis of the job procedures of those jobs, the ALARA improvements are also derived

  13. Teflon pastille use in high dose dosimetry; Utilizacao de pastilhas de teflon em dosimetria de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines [Associacao Educacional Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil); Caldas, Linda V.E., E-mail: miteixeira@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper study the Teflon, which is used as aglomerant in the confection of dosimetric pastilles, for the viabilization of this material as high dose dosimeter. This paper used the OSL technique for the characterization of dosimetric properties of Teflon. The doses-response curve has been obtained for {sup 60}Co radiation between 100 Gy and 50 kGy, and the OSL answer reproducibility. The preliminary results shown that the Teflon is a material which can be used for high dose dosimetry

  14. measurement of high dose radiation using yellow perspex dosimeter

    International Nuclear Information System (INIS)

    Thamrin, M Thoyib; Sofyan, Hasnel

    1996-01-01

    Measurement of high dose radiation using yellow perspex dosemeter has been carried out. Dose range used was between 0.1 to 3.0 kGy. Measurement of dose rate against Fricke dosemeter as a standard dose meter From the irradiation of Fricke dosemeter with time variation of 3,6,9,12,15 and 18 minute, it was obtained average dose rate of 955.57 Gy/hour, linear equation of dose was Y= 2.333+15.776 X with its correlation factor r = 0.9999. Measurement result using yellow perspex show that correlation between net optical density and radiation dose was not linear with its equation was ODc exp. [Bo + In(dose).Bi] Value of Bo = -0.215 and Bi=0.5020. From the experiment it was suggested that routine dosimeter (yellow perspex) should be calibrated formerly against standard dosemeters

  15. Examination of the somatostatin receptor status in non-medullary thyroid cancer; Untersuchungen zum Somatostatinrezeptor-Status bei nicht-medullaeren Schilddruesenkarzinomen

    Energy Technology Data Exchange (ETDEWEB)

    Goerges, R.; Brandt-Mainz, K.; Bockisch, A. [Essen Univ. (Gesamthochschule) (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Kahaly, G. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Medizin - Endokrinologie und Stoffwechselerkrankungen; Mueller-Brand, J.; Maecke, H. [Kantonsspital Basel (Switzerland). Inst. fuer Nuklearmedizin; Walgenbach, S. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Allgemein- und Abdominalchirurgie; Bruns, C. [Praeklinische Forschung Novartis, Basel (Switzerland); Andreas, J. [Universitaetsklinik Mainz (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    1999-06-01

    Aim: Recent in-vitro and in-vivo studies demonstrated a somatostatin receptor expression in some non-medullary thyroid carcinomas. In this study we investigated the somatostatin receptor status for this particular tumor entity in a larger patient group. Subject and methods: We compared 131-iodine with 111-In-pentetreotide scans in 24 patients with metastasizing, non-medullary thyroid cancer. The findings were correlated with other imaging modalities. Additionally, we performed receptor autoradiography in one patient, octreotide therapy in another patient and administration of 90-Y- and 111-In-DOTATOC in 2 consecutive patients. Results: In the 15 patients with papillary or follicular carcinoma, 111-In-pentetreotide was inferior to 131-I in 8/15, equal in 1/15, and superior in 6/15 patients. In 8/9 of the patients with Huerthle cell cacinoma, metastases showed a 111-In-pentetreotide accumulation of various intensity, while 131-iodine scans were negative except for one patient. 111-In-pentetreotide was equal or superior compared to 201-Tl or 99m-Tc-sestamibi, but for the most part inferior in comparison with 18-F-FDG-PET. The findings of 111-In-pentetreotide scintigraphy correlated well with the receptor autoradiography and the accumulation of DOTATOC, but not with the therapeutic effect of `cold` octreotide on the thyroid cancer metastases. Conclusions: Several metastases of papillary and follicular carcinoma, and the majority of Huerthle cell cancer metastases can express somatostatin receptors. 111-In-pentetreotide scintigraphy is a promising tool for localization of metastases especially in Huerthle cell cancer or if PET is not available, and may be useful for selection of possible candidates, if therapeutic effective {beta}-emitting somatostatin analogues will be available for routine application. (orig.) [Deutsch] Ziel: in aktuellen In-vitro und In-vivo-Untersuchungen wurde eine Somatostatinrezeptor-Expression bei einigen nicht

  16. Induction of Human Somatostatin Receptor Subtype 2 on Breast Tumors with an Adenoviral Vector for Their Treatment and Detection with a Radiolabeled Peptide

    National Research Council Canada - National Science Library

    Rogers, Buck

    2002-01-01

    .... An adenoviral vector encoding the human somatostatin receptor subtype 2 (AdSSTr2) has been produced. The MDA- MB-468 and BT-474 human breast cancer cells were infected with AdSSTr2 and harvested 48 h later for membrane preparations...

  17. Dynamic and static small-animal SPECT in rats for monitoring renal function after 177Lu-labeled Tyr3-octreotate radionuclide therapy.

    NARCIS (Netherlands)

    Melis, M.; Swart, J.; Visser, M. de; Berndsen, S.C.; Koelewijn, S.; Valkema, R.; Boerman, O.C.; Krenning, E.P.; Jong, M. de

    2010-01-01

    High kidney radiation doses during clinical peptide receptor radionuclide therapy (PRRT) with beta-particle-emitting radiolabeled somatostatin analogs will lead to renal failure several months after treatment, urging the coinfusion of the cationic amino acids lysine and arginine to reduce the renal

  18. Diagnosis of cerebral metastases by means of standard doses of Gadobutrol versus a high-dose protocol. Intraindividual evaluation of a phase-II high-dose study

    International Nuclear Information System (INIS)

    Vogl, T.J.; Friebe, C.E.; Balzer, T.; Mack, M.G.; Steiner, S.; Schedel, H.; Pegios, W.; Lanksch, W.; Banzer, D.; Felix, R.

    1995-01-01

    In a clinical phase-II study 20 patients who had been diagnosed as having brain metastases with CT or MRT were studied prospectively with Gadobutrol, a new nonionic, low osmolality contrast agent. Each patient received an initial injection of 0.1 mmol/kg body weight and an additional dose of 0.2 mmol/kg Gadobutrol 10 min later. Spinecho images were obtained before and after the two applications of Gadobutrol. Dynamic scanning (Turbo-FLASH) was performed for 3 min after each injection of the contrast agent. Both quantitative and qualitative data were intraindividually evaluated. The primary tumor was a bronchial carcinoma in 11 cases; in 9 other cases there were different primary tumors. Forty-eight hours after the use of Gadobutrol there were no adverse signs in the clinical examination, vital signs or blood and urine chemistry. Statistical analysis (Friedman test and Wilcoxon test) of the C/N ratios between tumor and white matter, percentage enhancement, and visual assessment rating revealed statistically significant superiority of high-dose Gadobutrol injection in comparison to the standard dose. The percentage enhancement increased on average from 104% after 0.1 mmol/kg to 162% after 0.3 mmol/kg Gadobutrol. Qualitative delineation and contrast of the lesions increased significantly. The use of high-dose Gadobutrol improved the detection of 36 additional lesions in 6 patients. (orig./VHE) [de

  19. High-resolution CT of the lung in asbestos-exposed subjects. Comparison of low-dose and high-dose HRCT

    International Nuclear Information System (INIS)

    Majurin, M.L.; Varpula, M.; Kurki, T.; Pakkala, L.

    1994-01-01

    The lowest possible mAs settings for high-resolution CT (HRCT) were studied on 45 individuals with suspected asbestos-related lung disease. All patients were investigated with 5 to 6 high-dose HRCT images (120 kVp/160 mA/2 s) at 3-cm intervals. At a selected level 4 additional low-dose images were obtained on each patient with lower mAs settings (100 mA/2 s, 80 mA/2 s, 60 mA/2 s, 30 mA/2 s). Thirty-seven subjects out of 45 had HRCT lesions compatible with asbestosis. HRCT images obtained with as low as 60 mA/2 s settings clearly showed pleural tractions and thickenings, parenchymal bands, honeycombing and subpleural curvilinear shadows, whereas in the evaluation of subpleural short lines and ground glass findings 80 mA/2 s were required. The lowest setting, 30 mA/2 s, was sufficient only in detecting and evaluating pleural tractions and thickenings. We conclude that 160 mAs yield good quality HRCT images, with substantial decrease of radiation dose, for the evaluation of asbestos-related lesions. (orig.)

  20. The clinical pharmacology of alkylating agents in high-dose chemotherapy

    NARCIS (Netherlands)

    Huitema, A. D.; Smits, K. D.; Mathôt, R. A.; Schellens, J. H.; Rodenhuis, S.; Beijnen, J. H.

    2000-01-01

    Alkylating agents are widely used in high-dose chemotherapy regimens in combination with hematological support. Knowledge about the pharmacokinetics and pharmacodynamics of these agents administered in high doses is critical for the safe and efficient use of these regimens. The aim of this review is

  1. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  2. Preclinical Study of 68Ga-DOTATOC: Biodistribution Assessment in Syrian Rats and Evaluation of Absorbed Dose in Human Organs.

    Science.gov (United States)

    Naderi, Mojdeh; Zolghadri, Samaneh; Yousefnia, Hassan; Ramazani, Ali; Jalilian, Amir Reza

    2016-01-01

    Gallium-68 DOTA-DPhe 1 -Tyr 3 -Octreotide ( 68 Ga-DOTATOC) has been applied by several European centers for the treatment of a variety of human malignancies. Nevertheless, definitive dosimetric data are yet unavailable. According to the Society of Nuclear Medicine and Molecular Imaging, researchers are investigating the safety and efficacy of this radiotracer to meet Food and Drug Administration requirements. The aim of this study was to introduce the optimized procedure for 68 Ga-DOTATOC preparation, using a novel germanium-68 ( 68 Ge)/ 68 Ga generator in Iran and evaluate the absorbed doses in numerous organs with high accuracy. The optimized conditions for preparing the radiolabeled complex were determined via several experiments by changing the ligand concentration, pH, temperature and incubation time. Radiochemical purity of the complex was assessed, using high-performance liquid chromatography and instant thin-layer chromatography. The absorbed dose of human organs was evaluated, based on biodistribution studies on Syrian rats via Radiation Absorbed Dose Assessment Resource Method. 68 Ga-DOTATOC was prepared with radiochemical purity of >98% and specific activity of 39.6 MBq/nmol. The complex demonstrated great stability at room temperature and in human serum at 37°C at least two hours after preparation. Significant uptake was observed in somatostatin receptor-positive tissues such as pancreatic and adrenal tissues (12.83 %ID/g and 0.91 %ID/g, respectively). Dose estimations in human organs showed that the pancreas, kidneys and adrenal glands received the maximum absorbed doses (0.105, 0.074 and 0.010 mGy/MBq, respectively). Also, the effective absorbed dose was estimated at 0.026 mSv/MBq for 68 Ga-DOTATOC. The obtained results showed that 68 Ga-DOTATOC can be considered as an effective agent for clinical PET imaging in Iran.

  3. Calcium carbonate as a possible dosimeter for high irradiation doses

    International Nuclear Information System (INIS)

    Negron M, A.; Ramos B, S.; Camargo R, C.; Uribe, R. M.; Gomez V, V.; Kobayashi, K.

    2014-08-01

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  4. Calcium carbonate as a possible dosimeter for high irradiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Negron M, A.; Ramos B, S.; Camargo R, C. [UNAM, Instituto de Ciencias Nucleares, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Uribe, R. M. [Kent State University, College of Technology, Kent OH (United States); Gomez V, V. [UNAM, Instituto de Quimica, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Kobayashi, K., E-mail: negron@nucleares.unam.mx [Yokohama National University (Japan)

    2014-08-15

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  5. Ectopic ACTH secretion due to a bronchopulmonary carcinoid localized by somatostatin receptor scintigraphy.

    Science.gov (United States)

    Iser, G; Pfohl, M; Dörr, U; Weiss, E M; Seif, F J

    1994-11-01

    We present the case of a 65-year-old woman with an adrenocorticotropic hormone (ACTH) secreting bronchopulmonary carcinoid. This patient showed the typical long history of Cushing's syndrome, including hypokaliemia, impaired glucose tolerance, high levels of ACTH and beta-endorphin, and coproduction of other peptides. At the onset of clinical symptoms in 1979 an adrenal adenoma was suspected, and left-sided adrenalectomy was performed. The symptoms soon recurred, and the diagnosis of ACTH-dependent Cushing's syndrome was made. As no ACTH-secreting tumor was found, the right adrenal was resected, and the patient was followed up regularly. Fourteen years later chest roentgenography and computed tomography revealed a para-aortic pulmonary lesion, which was suspicious for a bronchopulmonary carcinoid. ACTH and beta-endorphin were excessively, pancreatic polypeptide slightly elevated at that time. The final diagnosis was made using somatostatin receptor scintigraphy which confirmed the hormonal activity of the suspicious lesion; no additional focus was found. This method turned out to be not only a useful additional localization technique but also a promising tool for characterization and staging of a suspected ACTH-producing carcinoid. The tumor was resected curatively, and the diagnosis was confirmed histologically.

  6. Calibration of high-dose radiation facilities (Handbook)

    International Nuclear Information System (INIS)

    Gupta, B.L.; Bhat, R.M.

    1986-01-01

    In India at present several high intensity radiation sources are used. There are 135 teletheraphy machines and 65 high intensity cobalt-60 sources in the form of gamma chambers (2.5 Ci) and PANBIT (50 Ci). Several food irradiation facilities and a medical sterilization plant ISOMED are also in operation. The application of these high intensity sources involve a wide variation of dose from 10 Gy to 100 kGy. Accurate and reproducible radiation dosimetry is essential in the use of these sources. This handbook is especially compiled for calibration of high-dose radiation facilities. The first few chapters discuss such topics as interaction of radiation with matter, radiation chemistry, radiation processing, commonly used high intensity radiation sources and their special features, radiation units and dosimetry principles. In the chapters which follow, chemical dosimeters are discussed in detail. This discussion covers Fricke dosimeter, FBX dosimeter, ceric sulphate dosimeter, free radical dosimetry, coloured indicators for irrdiation verification. A final chapter is devoted to practical hints to be followed in calibration work. (author)

  7. Plasma Doping - Enabling Technology for High Dose Logic and Memory Applications

    International Nuclear Information System (INIS)

    Miller, T.; Godet, L.; Papasouliotis, G. D.; Singh, V.

    2008-01-01

    As logic and memory device dimensions shrink with each generation, there are more high dose implants at lower energies. Examples include dual poly gate (also referred to as counter-doped poly), elevated source drain and contact plug implants. Plasma Doping technology throughput and dopant profile benefits at these ultra high dose and lower energy conditions have been well established [1,2,3]. For the first time a production-worthy plasma doping implanter, the VIISta PLAD tool, has been developed with unique architecture suited for precise and repeatable dopant placement. Critical elements of the architecture include pulsed DC wafer bias, closed-loop dosimetry and a uniform low energy, high density plasma source. In this paper key performance metrics such as dose uniformity, dose repeatability and dopant profile control will be presented that demonstrate the production-worthiness of the VIISta PLAD tool for several high dose applications.

  8. Spectroscopic gamma camera for use in high dose environments

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Yuichiro, E-mail: yuichiro.ueno.bv@hitachi.com [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Fujishima, Yasutake; Kometani, Yutaka [Hitachi Works, Hitachi-GE Nuclear Energy, Ltd., Hitachi-shi, Ibaraki-ken (Japan); Suzuki, Yasuhiko [Measuring Systems Engineering Dept., Hitachi Aloka Medical, Ltd., Ome-shi, Tokyo (Japan); Umegaki, Kikuo [Faculty of Engineering, Hokkaido University, Sapporo-shi, Hokkaido (Japan)

    2016-06-21

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  9. Calibration procedure for thermoluminescent dosemeters in water absorbed doses for Iridium-192 high dose rate sources

    International Nuclear Information System (INIS)

    Reyes Cac, Franky Eduardo

    2004-10-01

    Thermoluminescent dosimeters are used in brachytherapy services quality assurance programs, with the aim of guaranteeing the correct radiation dose supplied to cancer patients, as well as with the purpose of evaluating new clinical procedures. This work describes a methodology for thermoluminescent dosimeters calibration in terms of absorbed dose to water for 192 Ir high dose rate sources. The reference dose used is measured with an ionization chamber previously calibrated for 192 Ir energy quality, applying the methodology proposed by Toelli. This methodology aims to standardizing the procedure, in a similar form to that used for external radiotherapy. The work evolves the adaptation of the TRS-277 Code of the International Atomic Energy Agency, for small and big cavities, through the introduction for non-uniform experimental factor, for the absorbed dose in the neighborhood of small brachytherapy sources. In order to simulate a water medium around the source during the experimental work, an acrylic phantom was used. It guarantees the reproducibility of the ionization chamber and the thermoluminescent dosimeter's location in relation to the radiation source. The values obtained with the ionization chamber and the thermoluminescent dosimeters, exposed to a 192 Ir high dose rate source, were compared and correction factors for different source-detector distances were determined for the thermoluminescent dosimeters. A numeric function was generated relating the correction factors and the source-detector distance. These correction factors are in fact the thermoluminescent dosimeter calibration factors for the 192 Ir source considered. As a possible application of this calibration methodology for thermoluminescent dosimeters, a practical range of source-detector distances is proposed for quality control of 192 Ir high dose rate sources. (author)

  10. Biological dose estimation and comet analysis of the victims in a high dose 60Co radiation accident

    International Nuclear Information System (INIS)

    Chen Ying; Liu Xiulin; Luo Yisheng; Li You; Yao Bo

    2007-01-01

    Objective: To explore the methods of chromosome preparation in human peripheral blood and bone marrow after very high dose exposure and fit the dose-response curve of dicentrics and tings in the range of high doses over 6 Gy for estimating biological dose and detecting DNA damage in the victims of '10.21' accident. Methods: The samples of peripheral blood and bone marrow in 2 victims were collected to prepare chromosome mataphases and dicentrics (multicentrics) + rings were counted. The dose-response curve and equation of human blood irradiated between 6-22 Gy in vitro were established and applied to assess biological dose of 2 victims. In addition, their DNA damages were tested by alkaline single cell gel electrophoresis. Results: The dicentric + ring numbers of 4.47 per cell in victims B's peripheral blood lymphocytes and 9.15 per cell in victim A's bone marrow who had no mitosis in peripheral blood cell. The whole body average doses of victims B and A estimated by 6-22 Gy equation arrived at 9.4 Gy and 19.5 Gy, respectively. The serious DNA damages were expressed by small head and large tail comet figures. Conclusions: The biological doses of 2 victims estimated by 6-22 Gy dose-response curve have reached the levels of extreme grave bone marrow and intestinal ARS, respectively. (authors)

  11. Preservation of Minced Meats by Using Medium and High-doses Irradiation

    International Nuclear Information System (INIS)

    Hammad, A.A.I.; Swailam, H.M.H.; Taha, S.M.A.

    2003-01-01

    The effect of medium (2.5-10 kGy) dose irradiation and high(20-70 kGy) dose irradiation on the microbiological, chemical and organoleptic properties of minced meat samples was studied. It was found that irradiation dose of only 5 kGy greatly reduced all microbial counts and completely eliminated all non-spore forming pathogenic bacteria contaminated minced meat samples. Consequently this irradiation dose extended the refrigerated (3 degree ±1) storage life of these products for more than 8 weeks. This irradiation dose almost did not affect the chemical composition, particularly the main amino acids and main fatty acids of minced meat samples. Panelists could not differentiate between irradiated minced meat samples at this dose and unirradiated samples. High doses irradiation, i.e.40 and 70 kGy were sufficient and efficient in sterilization of minced meat samples and in obtaining long-stable minced meat products (Two years) at ambient temperature. These irradiation doses slightly reduced (not more than 7%) aspartic acid, glutamic acid, methionine and lysine of minced meat. It also decreased the relative percentage of total unsaturated fatty acids by not more than 17 % . These high irradiation doses caused loss of C 18:3 and C 20:1

  12. Peripheral nervous system assessment in acromegaly patients under somatostatin analogue therapy.

    Science.gov (United States)

    Alibas, H; Gogas Yavuz, D; Kahraman Koytak, P; Uygur, M; Tanridag, T; Uluc, K

    2017-01-01

    Acromegaly is known to affect peripheral nervous system (PNS) causing carpal tunnel syndrome (CTS) and polyneuropathy. The frequency of these disorders and the evaluation methods vary among studies. In the present study, we aimed to examine PNS of acromegaly patients under somatostatin analogue (SSA) therapy. Forty-eight acromegaly patients (26 F/22 M, 45.58 ± 11.6 years) under SSA treatment and 44 healthy controls (25 F/19 M, 47.46 ± 8.7 years) were assessed by symptom questionnaires, neurologic examination and electrophysiological studies. 87.5 % of the acromegaly patients had at least one abnormal finding regarding PNS. With the incorporation of palm-wrist median nerve conduction velocity method, we detected CTS in 50 % of patients. Polyneuropathy was less frequent (29.2 %). Both conditions were independent from the coexisting diabetes mellitus (p = 0.22 for CTS, p = 0.71 for polyneuropathy). Polyneuropathy but not CTS was more common among biochemically uncontrolled acromegaly patients rather than those under control (p = 0.03; p = 0.68, respectively). Our findings emphasize the high prevalence of peripheral nervous system involvement in acromegaly patients under SSA therapy and importance of neurological evaluation of these patients. Early diagnosis and treatment of the disease may reduce the PNS involvement.

  13. Detecting somatostatin receptor in breast tumor tissue and its clinical significance

    International Nuclear Information System (INIS)

    Zhang Yongjian; Yu Xian; Lin Wei; Ding Xuan; Huang Shizhang; Lu Guangming

    2002-01-01

    The authors observe the difference of somatostatin receptor (SSR) between benign and malignant breast tumor and the relation between SSR and estrogen receptor (ER) or progesterone receptor (PR) in breast tumor tissue, and to predict the clinical value of detecting breast tumor by SSR receptor imaging. These tissues excised from operation in breast tumor were divided into 4 groups: breast malignant tumor group (BMTG) and its control group (C1G), breast benign tumor group (BBTG) and its control group (C2G). SSR was detected by radioligand binding assay (RBA) and ER, PR by LsAB method in these groups. Results is: (1) The SSR express quantity is 108.6 +- 67.3 fmol/mg pr, 37.2 +- 9.6 fmol/mg pr, 43.4 +- 12.6 fmol/mg pr 33.9 +- 10.2 fmol/mg pr respectively in BMTG, C1G, BBTG, C2G. The SSR of BMTG is the most among these groups, the difference is obvious, P 0.05); (2) The correlation coefficient of SSR and ER is 0.859, SSR and PR is 0.750. Most breast tumor tissues express high density SSR, the authors suppose that malignant tumor can been distinguished from benign tumor preliminarily by SSR receptor imaging. There is a good correlation between SSR and ER, PR, detecting SSR may predict the quality of tumor and the prognosis of the patient

  14. Efficacy and tolerability of high-dose phenobarbital in children with focal seizures.

    Science.gov (United States)

    Okumura, Akihisa; Nakahara, Eri; Ikeno, Mitsuru; Abe, Shinpei; Igarashi, Ayuko; Nakazawa, Mika; Takasu, Michihiko; Shimizu, Toshiaki

    2016-04-01

    We retrospectively reviewed the outcomes of children with focal epilepsy treated with oral high-dose phenobarbital. We reviewed data on children (agedphenobarbital (>5 mg/kg/day to maintain a target serum level >40 μg/mL) for at least 6 months. Seizure frequency was evaluated after phenobarbital titration, and 1 and 2 years after high-dose phenobarbital treatment commenced. Treatment was judged effective when seizure frequencies fell by ⩾75%. Seven boys and eight girls were treated. The median age at commencement of high-dose phenobarbital therapy was 30 months. The maximal serum phenobarbital level ranged from 36.5 to 62.9 μg/mL. High-dose PB was effective in seven. In two patients, treatment was transiently effective, but seizure frequency later returned to the baseline. High-dose PB was ineffective in six. No significant association between effectiveness and any clinical variable was evident. Drowsiness was recorded in nine patients, but no patient developed a behavioral problem or hypersensitivity. Oral high-dose phenobarbital was effective in 7 of 15 patients with focal epilepsy and well tolerated. High-dose PB may be useful when surgical treatment is difficult. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  15. Somatostatin-receptor-targeted α-emitting 213Bi is therapeutically more effective than β--emitting 177Lu in human pancreatic adenocarcinoma cells

    International Nuclear Information System (INIS)

    Nayak, Tapan K.; Norenberg, Jeffrey P.; Anderson, Tamara L.; Prossnitz, Eric R.; Stabin, Michael G.; Atcher, Robert W.

    2007-01-01

    Introduction: Advance clinical cancer therapy studies of patients treated with somatostatin receptor (sstr)-targeted [DOTA 0 -Tyr 3 ]octreotide (DOTATOC) labeled with low-linear-energy-transfer (LET) β - -emitters have shown overall response rates in the range of 15-33%. In order to improve outcomes, we sought to compare the therapeutic effectiveness of sstr-targeted high-LET α-emitting 213 Bi to that of low-LET β - -emitting 177 Lu by determining relative biological effectiveness (RBE) using the external γ-beam of 137 Cs as reference radiation. Methods: Sstr-expressing human pancreatic adenocarcinoma Capan-2 cells and A549 control cells were used for this study. The effects of different radiation doses of 213 Bi and 177 Lu labeled to 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid and sstr-targeted DOTATOC were investigated with a clonogenic cell survival assay. Apoptosis was measured using the Cell Death Detection ELISA PLUS 10x kit. Results: Using equimolar DOTATOC treatment with concurrent irradiation with a 137 Cs source as reference radiation, the calculated RBE of [ 213 Bi]DOTATOC was 3.4, as compared to 1.0 for [ 177 Lu]DOTATOC. As measured in terms of absorbance units, [ 213 Bi]DOTATOC caused a 2.3-fold-greater release of apoptosis-specific mononucleosomes and oligonucleosomes than [ 177 Lu]DOTATOC at the final treatment time of 96 h (P 213 Bi]DOTATOC is therapeutically more effective in decreasing survival than is [ 177 Lu]DOTATOC in human pancreatic adenocarcinoma cells due to its comparatively higher RBE

  16. Novel high dose rate lip brachytherapy technique to improve dose homogeneity and reduce toxicity by customized mold

    International Nuclear Information System (INIS)

    Feldman, Jon; Appelbaum, Limor; Sela, Mordechay; Voskoboinik, Ninel; Kadouri, Sarit; Weinberger, Jeffrey; Orion, Itzhak; Meirovitz, Amichay

    2014-01-01

    The purpose of this study is to describe a novel brachytherapy technique for lip Squamous Cell Carcinoma, utilizing a customized mold with embedded brachytherapy sleeves, which separates the lip from the mandible, and improves dose homogeneity. Seven patients with T2 lip cancer treated with a “sandwich” technique of High Dose Rate (HDR) brachytherapy to the lip, consisting of interstitial catheters and a customized mold with embedded catheters, were reviewed for dosimetry and outcome using 3D planning. Dosimetric comparison was made between the “sandwich” technique to “classic” – interstitial catheters only plan. We compared dose volume histograms for Clinical Tumor Volume (CTV), normal tissue “hot spots” and mandible dose. We are reporting according to the ICRU 58 and calculated the Conformal Index (COIN) to show the advantage of our technique. The seven patients (ages 36–81 years, male) had median follow-up of 47 months. Four patients received Brachytherapy and External Beam Radiation Therapy, 3 patients received brachytherapy alone. All achieved local control, with excellent esthetic and functional results. All patients are disease free. The Customized Mold Sandwich technique (CMS) reduced the high dose region receiving 150% (V150) by an average of 20% (range 1–47%), The low dose region (les then 90% of the prescribed dose) improved by 73% in average by using the CMS technique. The COIN value for the CMS was in average 0.92 as opposed to 0.88 for the interstitial catheter only. All differences (excluding the low dose region) were statistically significant. The CMS technique significantly reduces the high dose volume and increases treatment homogeneity. This may reduce the potential toxicity to the lip and adjacent mandible, and results in excellent tumor control, cosmetic and functionality

  17. Evaluation of Low- Versus High-dose Valganciclovir for Prevention of Cytomegalovirus Disease in High-risk Renal Transplant Recipients.

    Science.gov (United States)

    Gabardi, Steven; Asipenko, Natalya; Fleming, James; Lor, Kevin; McDevitt-Potter, Lisa; Mohammed, Anisa; Rogers, Christin; Tichy, Eric M; Weng, Renee; Lee, Ruth-Ann

    2015-07-01

    Despite proven efficacy of prolonged cytomegalovirus (CMV) prophylaxis using valganciclovir 900 mg/day, some centers use 450 mg/day due to reported success and cost savings. This multicenter, retrospective study compared the efficacy and safety of 6 months of low-dose versus high-dose valganciclovir prophylaxis in high-risk, donor-positive/recipient-negative, renal transplant recipients (RTR). Two hundred thirty-seven high-risk RTR (low-dose group = valganciclovir 450 mg/day [n = 130]; high-dose group = valganciclovir 900 mg/day [n = s7]) were evaluated for 1-year CMV disease prevalence. Breakthrough CMV, resistant CMV, biopsy-proven acute rejection (BPAR), graft loss, opportunistic infections (OI), new-onset diabetes after transplantation (NODAT), premature valganciclovir discontinuation, renal function and myelosuppression were also assessed. Patient demographics and transplant characteristics were comparable. Induction and maintenance immunosuppression were similar, except for more early steroid withdrawal in the high-dose group. Similar proportions of patients developed CMV disease (14.6% vs 24.3%; P = 0.068); however, controlling CMV risk factor differences through multivariate logistic regression revealed significantly lower CMV disease in the low-dose group (P = 0.02; odds ratio, 0.432, 95% confidence interval, 0.211-0.887). Breakthrough and resistant CMV occurred at similar frequencies. There was no difference in renal function or rates of biopsy-proven acute rejection, graft loss, opportunistic infections, or new-onset diabetes after transplantation. The high-dose group had significantly lower mean white blood cell counts at months 5 and 6; however, premature valganciclovir discontinuation rates were similar. Low-dose and high-dose valganciclovir regimens provide similar efficacy in preventing CMV disease in high-risk RTR, with a reduced incidence of leukopenia associated with the low-dose regimen and no difference in resistant CMV. Low-dose valganciclovir

  18. Normal uptake of 68Ga-DOTA-TOC by the pancreas uncinate process mimicking malignancy at somatostatin receptor PET.

    Science.gov (United States)

    Jacobsson, Hans; Larsson, Patricia; Jonsson, Cathrine; Jussing, Emma; Grybäck, Per

    2012-04-01

    To characterize a commonly occurring increased uptake by the uncinate process of the pancreas at PET/CT using 68Ga-DOTA-d-Phe1-Tyr3-octreotide (68Ga-DOTA-TOC). This tracer has replaced In pentetreotide (OctreoScan®) for somatostatin receptor scintigraphy at our laboratory. Fifty of our first 74 PET/CT examinations with 68Ga-DOTA-TOC could be evaluated in retrospect. None of these patients had surgery or showed any pathology in the pancreas head at the concomitant CT. Thirty-five of the 50 examinations (70%) showed an uptake by the uncinate process sufficiently intense to be interpreted as pathologic and simulating a tumor. Mean SUVmax was 9.2. Mean SUVmean using an isoactivity cut-off of >75% and >50% was 7.8 and 6.0, respectively. Volume calculations of the uncinate process activity using these definitions gave 0.9 mL and 4.2 mL, respectively. There is a frequent physiological uptake of 68Ga-DOTA-TOC by the pancreas uncinate process. This may be caused by an accumulation of pancreatic polypeptide-containing cells expressing somatostatin receptors. If there is a normal finding at concomitant diagnostic CT, this uptake should be regarded as physiological.

  19. Chromosomal Aberrations in Normal and AT Cells Exposed to High Dose of Low Dose Rate Irradiation

    Science.gov (United States)

    Kawata, T.; Shigematsu, N.; Kawaguchi, O.; Liu, C.; Furusawa, Y.; Hirayama, R.; George, K.; Cucinotta, F.

    2011-01-01

    Ataxia telangiectasia (A-T) is a human autosomally recessive syndrome characterized by cerebellar ataxia, telangiectases, immune dysfunction, and genomic instability, and high rate of cancer incidence. A-T cell lines are abnormally sensitive to agents that induce DNA double strand breaks, including ionizing radiation. The diverse clinical features in individuals affected by A-T and the complex cellular phenotypes are all linked to the functional inactivation of a single gene (AT mutated). It is well known that cells deficient in ATM show increased yields of both simple and complex chromosomal aberrations after high-dose-rate irradiation, but, less is known on how cells respond to low-dose-rate irradiation. It has been shown that AT cells contain a large number of unrejoined breaks after both low-dose-rate irradiation and high-dose-rate irradiation, however sensitivity for chromosomal aberrations at low-dose-rate are less often studied. To study how AT cells respond to low-dose-rate irradiation, we exposed confluent normal and AT fibroblast cells to up to 3 Gy of gamma-irradiation at a dose rate of 0.5 Gy/day and analyzed chromosomal aberrations in G0 using fusion PCC (Premature Chromosomal Condensation) technique. Giemsa staining showed that 1 Gy induces around 0.36 unrejoined fragments per cell in normal cells and around 1.35 fragments in AT cells, whereas 3Gy induces around 0.65 fragments in normal cells and around 3.3 fragments in AT cells. This result indicates that AT cells can rejoin breaks less effectively in G0 phase of the cell cycle? compared to normal cells. We also analyzed chromosomal exchanges in normal and AT cells after exposure to 3 Gy of low-dose-rate rays using a combination of G0 PCC and FISH techniques. Misrejoining was detected in the AT cells only? When cells irradiated with 3 Gy were subcultured and G2 chromosomal aberrations were analyzed using calyculin-A induced PCC technique, the yield of unrejoined breaks decreased in both normal and AT

  20. Peptide receptor radionuclide therapy of Merkel cell carcinoma using 177lutetium-labeled somatostatin analogs in combination with radiosensitizing chemotherapy. A potential novel treatment based on molecular pathology

    International Nuclear Information System (INIS)

    Salavati, A.; Prasad, V.; Baum, R.P.; Schneider, C.P.; Herbst, R.

    2012-01-01

    Few studies have been published on the safety and feasibility of synchronous use of peptide receptor radionuclide therapy (PRRNT), as source of internal radiation therapy, in combination with chemotherapy. In this study we reported a 53-year-old man with stage IV Merkel cell carcinoma (MCC), who underwent synchronous internal radiation therapy and chemotherapy. Based on presumable poor prognosis with chemotherapy only, functional similarities of MCC with other neuroendocrine tumors and available evidence of effectiveness and safety of synchronous use of external beam radiation therapy and chemotherapy in treatment of high-risk MCC patients, our interdisciplinary neuroendocrine tumor board recommended him to add PRRNT to his ongoing chemotherapy. He received 2 courses of 177 Lu-DOTATATE(1, 4, 7, 10-Tetraazacyclododecane-1, 4, 7, 10-tetraacetic acid-1-D-Phe1-Tyr3-Thr8-octreotide) in combination with ongoing 8 cycles of liposomal doxorubicin based on standard protocols. Response to therapy was evaluated by 18 F-fluorodeoxyglucose ( 18 F-FDG) and 68 gallium-somatostatin-receptor PET/CT. There was an impressive improvement of the clinical symptoms. However, follow-up positron emission tomography (PET)/CT studies showed mixed pattern of response. Synchronous use of PRRNT and radiosensitizing chemotherapy seems safe and feasible in high risk MCC patients, however, further prospective studies and clinical trials are warranted to provide reliable evidence of possible pitfalls and effectiveness of PRRNT and 68 Ga-somatostatin-receptor PET/CT in the management of MCC. (author)

  1. Dose finding study of granisetron in patients receiving high-dose cisplatin chemotherapy. The Granisetron Study Group.

    Science.gov (United States)

    Riviere, A.

    1994-01-01

    The efficacy and safety of three different doses of granisetron (2 micrograms kg-1, group A; 10 micrograms kg-1, group B; 40 micrograms kg-1, group C) were compared in a randomised, double-blind study of 157 patients due to receive high-dose cisplatin therapy (mean dose > 97 mg m-2). In each group, up to two 3 mg rescue doses of granisetron were allowed if more than mild nausea or vomiting occurred. In group A 30.8%, in group B 61.5% and in group C 67.9% of patients were complete responders (i.e. no vomiting or nothing worse than mild nausea) during the first 24 h. These differences are significant between groups A and B, and A and C. There were no statistically significant differences in any efficacy variable between the 10 micrograms kg-1 and 40 micrograms kg-1 groups, although in each case the trend favoured the higher dose. Additional rescue doses resulted in resolved or improved symptoms in 95.3% for the first rescue dose and 93.3% for the second. Over the 7 days of the study, 82.7%, 82.7% and 86.8% of patients in groups A, B and C respectively were treated with granisetron alone. Headache was the most common side-effect, reported by 9.6% of patients; the majority of headaches were mild. There was no difference between the treatment groups regarding the adverse event rate. We concluded that prophylactic doses of 10 or 40 micrograms kg-1 lead to a safe and satisfactory degree of control of nausea and vomiting induced by high-dose cisplatin. PMID:8180032

  2. Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?

    Science.gov (United States)

    Day, Troy; Read, Andrew F.

    2016-01-01

    High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients. PMID:26820986

  3. High-dose zolpidem dependence - Psychostimulant effects? A case report and literature review

    Directory of Open Access Journals (Sweden)

    Abhijna Chandan Chattopadhyay

    2016-01-01

    Full Text Available Zolpidem, an imidazoline nonbenzodiazepine sedative drug, is used widely. Initial reports showed minimal abuse potential. However, multiple reports have appeared of dose escalation and abuse. Subjective effects of high-dose zolpidem are not known. In light of accumulating evidence of abuse potential, we hereby report a case of high-dose dependence and a review of relevant literature. A 33-year-old male presented with 5 years of daily use of 600–1700 mg of zolpidem tartrate. He reported subjective effects of euphoria, intense craving, and inability to stop use. Loss of receptor specificity, pharmacokinetic factors, and different receptor distributions can explain paradoxical stimulatory effects of high-dose zolpidem. Further studies are required to characterize subjective effects of high-dose zolpidem.

  4. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  5. δ-opioid receptor and somatostatin receptor-4 heterodimerization: possible implications in modulation of pain associated signaling.

    Directory of Open Access Journals (Sweden)

    Rishi K Somvanshi

    Full Text Available Pain relief is the principal action of opioids. Somatostatin (SST, a growth hormone inhibitory peptide is also known to alleviate pain even in cases when opioids fail. Recent studies have shown that mice are prone to sustained pain and devoid of analgesic effect in the absence of somatostatin receptor 4 (SSTR4. In the present study, using brain slices, cultured neurons and HEK-293 cells, we showed that SSTR4 and δ-Opioid receptor (δOR exist in a heteromeric complex and function in synergistic manner. SSTR4 and δOR co-expressed in cortical/striatal brain regions and spinal cord. Using cultured neuronal cells, we describe the heterogeneous complex formation of SSTR4 and δOR at neuronal cell body and processes. Cotransfected cells display inhibition of cAMP/PKA and co-activation of SSTR4 and δOR oppose receptor trafficking induced by individual receptor activation. Furthermore, downstream signaling pathways either associated with withdrawal or pain relief are modulated synergistically with a predominant role of SSTR4. Inhibition of cAMP/PKA and activation of ERK1/2 are the possible cellular adaptations to prevent withdrawal induced by chronic morphine use. Our results reveal direct intra-membrane interaction between SSTR4 and δOR and provide insights for the molecular mechanism for the anti-nociceptive property of SST in combination with opioids as a potential therapeutic approach to avoid undesirable withdrawal symptoms.

  6. Radiation exposure for 'caregivers' during high-dose outpatient radioiodine therapy

    International Nuclear Information System (INIS)

    Marriott, C. J.; Webber, C. E.; Gulenchyn, K. Y.

    2007-01-01

    On 27 occasions, radiation doses were measured for a family member designated as the 'caregiver' for a patient receiving high-dose radioiodine outpatient therapy for differentiated thyroid carcinoma. For 25 of the administrations, patients received 3.7 GBq of 131 I. Radiation doses for the designated caregivers were monitored on an hourly basis for 1 week using electronic personal dosemeters. The average penetrating dose was 98±64 μSv. The maximum penetrating dose was 283 μSv. Measured dose rate profiles showed that, on average, one-third of the caregiver dose was received during the journey home from hospital. The mean dose rate profile showed rapid clearance of 131 I with three distinct phases. The corresponding clearance half-times were 131 I contaminating the home. (authors)

  7. High-Dose versus Low-Dose Vitamin D Supplementation and Arterial Stiffness among Individuals with Prehypertension and Vitamin D Deficiency

    Directory of Open Access Journals (Sweden)

    Amanda Zaleski

    2015-01-01

    Full Text Available Introduction. Vitamin D deficiency is associated with the onset and progression of hypertension and cardiovascular disease (CVD. However, mechanisms underlying vitamin D deficiency-mediated increased risk of CVD remain unknown. We sought to examine the differential effect of high-dose versus low-dose vitamin D supplementation on markers of arterial stiffness among ~40 vitamin D deficient adults with prehypertension. Methods. Participants were randomized to high-dose (4000 IU/d versus low-dose (400 IU/d oral vitamin D3 for 6 months. 24 hr ambulatory blood pressure (BP, carotid-femoral pulse wave velocity, and pulse wave analyses were obtained at baseline and after 6 months of vitamin D supplementation. Results. There were no changes in resting BP or pulse wave velocity over 6 mo regardless of vitamin D dose (all p>0.202. High-dose vitamin D decreased augmentation index and pressure by 12.3 ± 5.3% (p=0.047 and 4.0 ± 1.5 mmHg (p=0.02, respectively. However, these decreases in arterial stiffness were not associated with increases in serum 25-hydroxyvitamin D over 6 mo (p=0.425. Conclusion. High-dose vitamin D supplementation appears to lower surrogate measures of arterial stiffness but not indices of central pulse wave velocity. Clinical Trial Registration. This trial is registered with www.clinicaltrials.gov (Unique Identifier: NCT01240512.

  8. High dose calibrations at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    McDonald, J.C.; Fox, R.A.

    1988-10-01

    The need is increasing for both high radiation exposures and calibration measurements that provide traceability of such exposures to national standards. The applications of high exposures include: electronic component damage studies, sterilization of medical products and food irradiation. Accurate high exposure measurements are difficult to obtain and cannot, in general, be carried out with a single dose measurement system or technique because of the wide range of doses and the variety of materials involved. This paper describes the dosimetric measurement and calibration techniques used at the Pacific Northwest Laboratory (PNL) that make use of radiochromic dye films, thermoluminescent dosimeters (TLDs), ionization chambers, and calorimetric dosimeters. The methods used to demonstrate the consistency of PNL calibrations with national standards will also be discussed. 4 refs

  9. SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

    Energy Technology Data Exchange (ETDEWEB)

    Moirano, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

  10. Immunohistochemical Detection and Localization of Somatostatin Receptor Subtypes in Prostate Tissue from Patients with Bladder Outlet Obstruction

    Directory of Open Access Journals (Sweden)

    Rodolfo Montironi

    2008-01-01

    Full Text Available Background and Aim of the Study: Scant information on the cellular distribution of the five somatostatin receptor (SSTR subtypes in the normal prostate and in neoplasms of the prostate has been reported in very few studies in which techniques, such as in situ hybridization histochemistry, autoradiography, and more recently immunohistochemistry, have been applied. The aim of the study was to examine immunohistochemically the distribution and localization of these 5 subtypes in the various tissue components in normal prostate.

  11. Comparative study of SOI/Si hybrid substrates fabricated using high-dose and low-dose oxygen implantation

    International Nuclear Information System (INIS)

    Dong Yemin; Chen Meng; Chen Jing; Wang Xiang; Wang Xi

    2004-01-01

    Hybrid substrates comprising both silicon-on-insulator (SOI) and bulk Si regions have been fabricated using the technique of patterned separation by implantation of oxygen (SIMOX) with high-dose (1.5 x 10 18 cm -2 ) and low-dose ((1.5-3.5) x 10 17 cm -2 ) oxygen ions, respectively. Cross-sectional transmission electron microscopy (XTEM) was employed to examine the microstructures of the resulting materials. Experimental results indicate that the SOI/Si hybrid substrate fabricated using high-dose SIMOX is of inferior quality with very large surface height step and heavily damaged transitions between the SOI and bulk regions. However, the quality of the SOI/Si hybrid substrate is enhanced dramatically by reducing the implant dose. The defect density in transitions is reduced considerably. Moreover, the expected surface height difference does not exist and the surface is exceptionally flat. The possible mechanisms responsible for the improvements in quality are discussed

  12. Clinical applications of somatostatin analogs for growth hormone-secreting pituitary adenomas

    Directory of Open Access Journals (Sweden)

    Wang JW

    2014-01-01

    Full Text Available Ji-wen Wang,1,2 Ying Li,3 Zhi-gang Mao,1,2 Bin Hu,1,2 Xiao-bing Jiang,1,2 Bing-bing Song,4 Xin Wang,4 Yong-hong Zhu,4 Hai-jun Wang1,21Department of Neurosurgery and Pituitary Tumor Center, The First Affiliated Hospital, Sun Yat-sen University, 2Key Laboratory of Pituitary Adenoma in Guangdong Province, 3State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, 4Department of Histology and Embryology, Zhongshan School of Medicine, Sun Yat-sen University, Guangzhou, People's Republic of ChinaAbstract: Excessive growth hormone (GH is usually secreted by GH-secreting pituitary adenomas and causes gigantism in juveniles or acromegaly in adults. The clinical complications involving cardiovascular, respiratory, and metabolic systems lead to elevated morbidity in acromegaly. Control of serum GH and insulin-like growth factor (IGF 1 hypersecretion by surgery or pharmacotherapy can decrease morbidity. Current pharmacotherapy includes somatostatin analogs (SAs and GH receptor antagonist; the former consists of lanreotide Autogel (ATG and octreotide long-acting release (LAR, and the latter refers to pegvisomant. As primary medical therapy, lanreotide ATG and octreotide LAR can be supplied in a long-lasting formulation to achieve biochemical control of GH and IGF-1 by subcutaneous injection every 4–6 weeks. Lanreotide ATG and octreotide LAR provide an effective medical treatment, whether as a primary or secondary therapy, for the treatment of GH-secreting pituitary adenoma; however, to maximize benefits with the least cost, several points should be emphasized before the application of SAs. A comprehensive assessment, especially of the observation of clinical predictors and preselection of SA treatment, should be completed in advance. A treatment process lasting at least 3 months should be implemented to achieve a long-term stable blood concentration. More satisfactory surgical outcomes for noninvasive macroadenomas treated

  13. PET/CT imaging of human somatostatin receptor 2 (hsstr2) as reporter gene for gene therapy

    International Nuclear Information System (INIS)

    Hofmann, M.; Gazdhar, A.; Weitzel, T.; Schmid, R.; Krause, T.

    2006-01-01

    Localized information on region-selective gene expression in small animals is widely obtained by use of reporter genes inducing light emission. Using these reporter genes for imaging deep inside the human body fluorescent probes are hindered by attenuation, scattering and possible fluorescence quenching. This can be overcome by use of radio-peptide receptors as reporter genes. Therefore, the feasibility of the somatostatin receptor 2 expression vector system for expression imaging was checked against a control vector containing luciferase gene. For in vivo transduction of vector DNA into the rat forelimb muscles the in vivo electroporation technique was chosen because of its high regio-selectivity. The gene expression was imaged by high-sensitive CCD camera (luciferase activity) and by PET/CT using a Ga-68-DOTATOC as radio peptide probe. The relative sstr2 expression was enhanced by gene transduction at maximum to a factor of 15. The PET/CT images could be fully quantified. The above demonstrated feasibility of radio-peptide PET/CT reporter gene imaging may serve in the future as a tool for full quantitative understanding of regional gene expression, especially in large animals and humans

  14. PET/CT imaging of human somatostatin receptor 2 (hsstr2) as reporter gene for gene therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, M. [Molecular Imaging and Therapy Group (MIT-Bern), Clinic of Nuclear Medicine, Inselspital, Medical School Bern (Switzerland)]. E-mail: Michael.Hofmann@insel.ch; Gazdhar, A. [Division of Pulmonary Medicine, University Hospital Bern (Switzerland); Weitzel, T. [Molecular Imaging and Therapy Group (MIT-Bern), Clinic of Nuclear Medicine, Inselspital, Medical School Bern (Switzerland); Schmid, R. [Division of Thoracic Surgery, University Hospital Bern (Switzerland); Krause, T. [Molecular Imaging and Therapy Group (MIT-Bern), Clinic of Nuclear Medicine, Inselspital, Medical School Bern (Switzerland)

    2006-12-20

    Localized information on region-selective gene expression in small animals is widely obtained by use of reporter genes inducing light emission. Using these reporter genes for imaging deep inside the human body fluorescent probes are hindered by attenuation, scattering and possible fluorescence quenching. This can be overcome by use of radio-peptide receptors as reporter genes. Therefore, the feasibility of the somatostatin receptor 2 expression vector system for expression imaging was checked against a control vector containing luciferase gene. For in vivo transduction of vector DNA into the rat forelimb muscles the in vivo electroporation technique was chosen because of its high regio-selectivity. The gene expression was imaged by high-sensitive CCD camera (luciferase activity) and by PET/CT using a Ga-68-DOTATOC as radio peptide probe. The relative sstr2 expression was enhanced by gene transduction at maximum to a factor of 15. The PET/CT images could be fully quantified. The above demonstrated feasibility of radio-peptide PET/CT reporter gene imaging may serve in the future as a tool for full quantitative understanding of regional gene expression, especially in large animals and human000.

  15. Overview of Development and Formulation of ¹⁷⁷Lu-DOTA-TATE for PRRT.

    Science.gov (United States)

    Breeman, Wouter A P; Chan, Ho Sze; de Zanger, Rory M S; Konijnenberg, Mark K; de Blois, Erik

    2016-01-01

    Peptide receptor radionuclide therapy (PRRT) using radiolabeled somatostatin analogs has become an established procedure for the treatment of patients suffering from inoperable neuroendocrine cancers over-expressing somatostatin receptors. Success of PRRT depends on the availability of the radiolabeled peptide with adequately high specific activity, so that required therapeutic efficacy can be achieved without saturating the limited number of receptors available on the target lesions. Specific activity of the radionuclide and the radiolabeled somatostatin analog are therefore an important parameters. Although these analogs have been investigated and improved, and successfully applied for PRRT for more than 15 years, there are still many possibilities for further improvements that fully exploit PRRT with 177Lu-DOTA-TATE. The here summarized data presented herein on increased knowledge of the components of 177Lu-DOTA-TATE (especially the purity of 177Lu and specific activity of 177Lu) and the reaction kinetics during labeling 177Lu-DOTA-TATE clearly show that the peptide dose and dose in GBq can be varied. Here we present an overview of the development, formulation and optimisation of 177Lu-DOTA-TATE, mainly addressing radiochemical parameters.

  16. Synthesis and evaluation in vitro in cancer cells AR42J of the radiopharmaceutical 99mTc-Tyr3-Octreotide-dendrimer similar of somatostatin

    International Nuclear Information System (INIS)

    Orocio R, E.

    2013-01-01

    The objective of this project was preparing a multimeric system through the conjugation of several molecules of the peptide Tyr 3 -Octreotide to a dendrimer molecule based on Poly-amidoamine (PAMAM), as well as radiolabeled with 99m Tc and evaluating its behavior like new radiopharmaceutical similar of somatostatin. The dendrimer PAMAM generation 3.5 that possesses terminal groups of sodium carboxylate, was functionalized to peptide Tyr 3 -Octreotide through a reaction of peptide coupling with HATU (hexafluorophosphate (V) of 1-oxide-3-(bis(dimethylamino)methylene)-3H-[1,2,3]triazole[4,5-b]pyridine) as activating agent of carboxylate groups using the Size Exclusion Chromatography (Sec) as purification method. The product was characterized by Ultraviolet visible spectrophotometry, Mid-infrared and Far-infrared, Elemental analysis, Energy dispersive X-ray spectroscopy, Scanning electron microscopy, Thermogravimetry and Differential scanning calorimetry. The radiolabeled with 99m Tc was carried out using a direct method that involves the reduction of the anion TcO 4 - with stannous chloride, so that the dendrimer is capable of coordinating to the technetium forming a chelate compound. The radiochemical purity of the radiolabeled compound was determined by thin layer chromatography using a sodium chloride solution to 20% (m/v) as mobile phase and was verified by molecular exclusion chromatography. The radiolabeled compound was possible to obtain it with a radiochemical purity superior to 90%. Also, the specific and not specific union was evaluated of the synthesized compound in mouse pancreas cancer cells AR42J, positive to somatostatin receptors, showing specific recognition for this receptors type with high cellular internalization. The biodistribution studies were carried out in BALB/c mice at different post injection times and in nude mice with induced tumors AR42J. The results showed that the 99m Tc-PAMAM-Tyr 3 -Octreotide is excreted by via renal as hepatobiliary

  17. Effects of low dose gamma radiation on the early growth of red pepper and the resistance to subsquent high dose of radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. S.; Baek, M. H.; Kim, D. H.; Lee, Y. K. [KAERI, Taejon (Korea, Republic of); Lee, Y. B. [Chungnam National Univ., Taejon (Korea, Republic of)

    2001-05-01

    Red pepper (capsicum annuum L. cv. Jokwang and cv. Johong) seeds were irradiated with the dose of 0{approx}50 Gy to investigated the effect of the low dose gamma radiation on the early growth and resistance to subsequent high dose of radiation. The effect of the low dose gamma radiation on the early growth and resistance to subsequenct high dose of radiation were enhanced in Johong cultivar but not in Jokwang cultivar. Germination rate and early growth of Johong cultivar were noticeably increased at 4 Gy-, 8 Gy- and 20 Gy irradiation group. Resistance to subsequent high dose of radiation of Johong cultivar were increased at almost all of the low dose irradiation group. Especially it was highest at 4 Gy irradiation group. The carotenoid contents and enzyme activity on the resistance to subsequent high dose of radiation of Johong cultivar were increased at the 4 Gy and 8 Gy irradiation group.

  18. Multifocal Electroretinography after High Dose Chloroquine Therapy for Malaria

    Directory of Open Access Journals (Sweden)

    Aline Correa de Carvalho

    2013-01-01

    Full Text Available Purpose: To investigate changes in multifocal electroretinography (mfERG parameters associated with high dose chloroquine therapy for treatment of malaria in the Amazonia region of Brazil. Methods: Forty-eight subjects who had received chloroquine treatment for single or multiple malaria infections with a cumulative dose ranging from 1,050 to 27,000mg were included. The control group consisted of 37 healthy aged-matched subjects. Data was collected on amplitude and implicit time of the N1, P1 and N2 waves in the central macular hexagon (R1 and in five concentric rings at different retinal eccentricities (R2-R6. Results: No significant difference was observed in any mfERG parameter between chloroquine treated patients and control subjects. A comparison with previous data obtained from patients with rheumatologic disorders in the same region of Brazil who had received larger cumulative doses of chloroquine and had displayed mfERG changes, indicated that retinal toxicity seems to be dependent on cumulative dose. Conclusion: Lack of mfERG changes in the current study suggests that intensive high dose chloroquine therapy for treatment of malaria is not associated with retinal toxicity.

  19. Transperineal high-dose-rate interstitial radiation therapy in the management of gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Itami, Jun; Hara, Ryuseke; Kozuka, Takuyou; Yamashita, Hideomi; Nakajima, Kaori; Shibata, Kouji; Abe, Yoshihisa; Fuse, Masashi; Ito, Masashi [International Medical Center of Japan, Tokyo (Japan). Dept. of Radiation Therapy and Oncology

    2003-11-01

    Background: High-dose-rate interstitial radiation therapy is a newly introduced modality, and its role in the management of gynecologic malignancies remains to be studied. Clinical experience in high-dose-rate interstitial radiation therapy was retrospectively investigated. Patients and Methods: Eight patients with primary and nine with recurrent gynecologic malignancies underwent high-dose-rate interstitial radiation therapy with/without external-beam irradiation. Fractional dose of the high-dose-rate interstitial radiation therapy ranged between 4 and 6 Gy with total doses of 15-54 Gy. Interstitial irradiation was performed twice daily with an interval of > 6 h. Results: 2-year local control rate was 75% for primary treatment and 47% for treatment of recurrence (p = 0.46). Maximum tumor size had a statistically significant impact on local control (p < 0.002). Grade 2 and 4 late complications were seen in five patients, and the incidence was significantly higher in patients with a larger volume enclosed by the prescribed fractional dose of high-dose-rate interstitial radiation therapy. The incidence of grade 2 and 4 complications at 18 months was 78% and 0% with a volume > 100 cm{sup 3} and {<=} 100 cm{sup 3}, respectively (p < 0.04). Conclusion: Although high-dose-rate interstitial radiation therapy is a promising modality, it must be applied cautiously to patients with bulky tumors because of the high incidence of serious complications. (orig.)

  20. Stock selection of high-dose-irradiation-resistant materials for filter press under high-dose irradiation operation

    International Nuclear Information System (INIS)

    Ishiyama, Shintaro; Minami, Mamoru; Hara, Kouji; Yamashita, Manabu

    2015-01-01

    In a volume reduction process for the decontamination of contained soil, the performance degradation of a filter press is expected owing to material deterioration under high-dose irradiation. Eleven-stock selection of candidate materials including polymers, fibers and rubbers for the filter press was conducted to achieve a high performance of volume reduction of contaminated soil and the following results were derived. Crude rubber and nylon were selected as prime candidates for packing, diaphragm and filter plate materials. Polyethylene was also selected as a prime candidate for the filter cloth material. (author)

  1. The Role of High Dose Interleukin-2 in the Era of Targeted Therapy.

    Science.gov (United States)

    Gills, Jessie; Parker, William P; Pate, Scott; Niu, Sida; Van Veldhuizen, Peter; Mirza, Moben; Holzbeierlein, Jeffery M; Lee, Eugene K

    2017-09-01

    We assessed survival outcomes following high dose interleukin-2 in a contemporary cohort of patients during the era of targeted agents. We retrospectively reviewed the records of patients with metastatic renal cell carcinoma treated with high dose interleukin-2 between July 2007 and September 2014. Clinicopathological data were abstracted and patient response to therapy was based on RECIST (Response Evaluation Criteria In Solid Tumors), version 1.1 criteria. The Kaplan-Meier method was used to estimate progression-free and overall survival in the entire cohort, the response to high dose interleukin-2 in regard to previous targeted agent therapy and the response to the targeted agent in relation to the response to high dose interleukin-2. We identified 92 patients, of whom 87 had documentation of a response to high dose interleukin-2. Median overall survival was 34.4 months from the initiation of high dose interleukin-2 therapy in the entire cohort. Patients who received targeted therapy before high dose interleukin-2 had overall survival (median 34.4 and 30.0 months, p = 0.88) and progression-free survival (median 1.5 and 1.7 months, p = 0.8) similar to those in patients who received no prior therapy, respectively. Additionally, patients with a complete or partial response to high dose interleukin-2 had similar outcomes for subsequent targeted agents compared to patients whose best response was stable or progressive disease (median overall survival 30.1 vs 25.4 months, p = 0.4). Our data demonstrate that patient responses to high dose interleukin-2 and to targeted agents before and after receiving high dose interleukin-2 are independent. As such, carefully selected patients should be offered high dose interleukin-2 for the possibility of a complete and durable response without the fear of limiting the treatment benefit of targeted agents. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. Modulation of hepatic reticuloendothelial system phagocytosis by pancreatic hormones.

    Science.gov (United States)

    Cornell, R P; McClellan, C C

    1982-12-01

    Experiments were conducted to determine the influence of the pancreatic hormones insulin, glucagon, and somatostatin on reticuloendothelial system (RES) phagocytosis both in vivo and in the isolated perfused livers of rats. Chronic pancreatic hormonal treatment consisted of twice daily injections SC of NPH insulin with doses ranging from 0.75 U on day 1 to 9.0 U on day 13 and unchanged doses of glucagon (200 micrograms) and somatostatin (50 micrograms). Chronic treatment with insulin significantly depressed by 48% intravascular phagocytosis of colloidal carbon administered IV at a dose of 8 mg/100 g, while glucagon and somatostatin stimulated macrophage endocytic function by 32% and 26%, respectively, compared to the control value. Acute treatment with the three pancreatic hormones at 30 min prior to carbon administration similarly produced insulin depression as well as glucagon and somatostatin stimulation of RES phagocytosis. Addition of the three hormones at near physiologic concentrations (20 ng/ml for insulin, 10 ng/ml for glucagon, and 5 ng/ml for somatostatin) to the recirculating perfusate of isolated perfused rat livers simultaneous with 24 mg of colloidal carbon likewise resulted in phagocytic reduction after insulin and enhancement after glucagon and somatostatin. Experiments involving insulin in vitro with isolated perfused livers as well as glucose replacement therapy concomitant with insulin in vivo demonstrated that hypoglycemia is not necessary for phagocytic depression by insulin while severe hypoglycemia in the perfusion medium is sufficient to depress carbon uptake by isolated perfused livers independent of insulin. Both pancreatic hormones and the level of glycemia seem to be important in modulating hepatic reticuloendothelial system phagocytosis.

  3. Effective dose calculation in CT using high sensitivity TLDs

    International Nuclear Information System (INIS)

    Brady, Z.; Johnston, P.N.

    2010-01-01

    Full text: To determine the effective dose for common paediatric CT examinations using thermoluminescence dosimetry (TLD) mea surements. High sensitivity TLD chips (LiF:Mg,Cu,P, TLD-IOOH, Thermo Fisher Scientific, Waltham, MA) were calibrated on a linac at an energy of 6 MY. A calibration was also performed on a superricial X-ray unit at a kilovoltage energy to validate the megavoltage cali bration for the purpose of measuring doses in the diagnostic energy range. The dose variation across large organs was assessed and a methodology for TLD placement in a 10 year old anthropomorphic phantom developed. Effective dose was calculated from the TLD measured absorbed doses for typical CT examinations after correcting for the TLD energy response and taking into account differences in the mass energy absorption coefficients for different tissues and organs. Results Using new tissue weighting factors recommended in ICRP Publication 103, the effective dose for a CT brain examination on a 10 year old was 1.6 millisieverts (mSv), 4.9 mSv for a CT chest exa ination and 4.7 mSv for a CT abdomen/pelvis examination. These values are lower for the CT brain examination, higher for the CT chest examination and approximately the same for the CT abdomen/ pelvis examination when compared with effective doses calculated using ICRP Publication 60 tissue weighting factors. Conclusions High sensitivity TLDs calibrated with a radiotherapy linac are useful for measuring dose in the diagnostic energy range and overcome limitations of output reproducibility and uniformity asso ciated with traditional TLD calibration on CT scanners or beam quality matched diagnostic X-ray units.

  4. HIGH-DOSE RATE BRACHYTHERAPY IN CARCINOMA CERVIX STAGE IIIB

    Directory of Open Access Journals (Sweden)

    Sathya Maruthavanan

    2016-07-01

    Full Text Available INTRODUCTION Radiotherapy is the standard treatment in locally advanced (IIB-IVA and early inoperable cases. The current standard of practice with curable intent is concurrent chemoradiation in which intracavitary brachytherapy is an integral component of radiotherapy. This study aims at assessing the efficacy of HDR ICBT (High-dose rate intracavitary brachytherapy in terms local response, normal tissue reactions, and feasibility. METHODS AND MATERIALS A total of 20 patients of stage IIIB cancer of the uterine cervix were enrolled in the study and were planned to receive concurrent chemotherapy weekly along with EBRT (external beam radiotherapy to a dose of 50 Gy/25 Fr. Suitability for ICBT was assessed at 40 Gy/20 Fr. 6/20 patients were suitable at 40 Gy and received HDR ICBT with a dose of 5.5 Gy to point A in 4 sessions (5.5 Gy/4 Fr. The remaining 14/20 patients completed 50 Gy and received HDR ICBT with a dose of 6 Gy to point A in 3 sessions (6 Gy/3 Fr. RESULTS A total of 66 intracavitary applications were done and only one application required dose modification due to high bladder dose, the pelvic control rate was 85% (17/20. 10% (2/20 had stable disease and 5% (1/20 had progressive disease at one year of follow up. When toxicity was considered only 15% developed grade I and grade II rectal complications. Patient compliance and acceptability was 100%. Patients were very comfortable with the short treatment time as compared with patients on LDR ICBT (low-dose rate intracavitary brachytherapy treatment interviewed during the same period. CONCLUSION This study proves that HDR brachytherapy is efficacious and feasible in carcinoma of cervix stage IIIB. It also proves that good dose distribution can be achieved with HDR intracavitary facility by the use of dose optimization. The short treatment time in HDR ICBT makes it possible to maintain this optimised dose distribution throughout the treatment providing a gain in the therapeutic ratio and

  5. High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Basavatia, Amar; Bayliss, Adam; Tome, Wolfgang A.

    2011-01-01

    Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within ±1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

  6. Does somatostatin have a role in the regulation of cortisol secretion in primary pigmented nodular adrenocortical disease (PPNAD)? A clinical and in vitro investigation

    NARCIS (Netherlands)

    Z. Bram (Zakariae); P. Xekouki (Paraskevi); E. Louiset (Estelle); M. Keil (Mark); D. Avgeropoulos (Dimitrios); C. Giatzakis (Christoforos); M. Nesterova (Maria); N. Sinaii (Ninet); L.J. Hofland (Leo); R. Cherqaoui (Rabia); H. Lefebvre (Hervé); C.A. Stratakis (Constantine)

    2014-01-01

    textabstractContext: Somatostatin (SST) receptors (SSTRs) are expressed in a number of tissues, including the adrenal cortex, but their role in cortisol secretion has not been well characterized. Objectives: The objective of the study was to investigate the expression of SSTRs in the adrenal cortex

  7. Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.

    Science.gov (United States)

    Vila, Andrea; Pagella, Hugo; Amadio, Claudio; Leiva, Alejandro

    2016-12-01

    Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30-60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is

  8. Receptor-mediated radiotherapy with Y-DOTA-DPhe-Tyr-octreotide: the experience of the European Institute of Oncology Group.

    Science.gov (United States)

    Chinol, Marco; Bodei, Lisa; Cremonesi, Marta; Paganelli, Giovanni

    2002-04-01

    High concentrations of subtype 2 somatostatin tumor receptors (sst(2)) are expressed in numerous tumors, enabling primary and metastatic masses to be localized by scintigraphy after injecting (111)In-labeled somatostatin analogue octreotide. In addition to neuroendocrine tumors, somatostatin receptors have been identified on cancers of the central nervous system, breast, lung, and lymphatic tissue, and the use of radionuclide-labeled somatostatin analogues appeared promising for therapy as well as for diagnosis of such malignancies. The somatostatin analogue [DOTA-(D)Phe(1)-Tyr(3)] octreotide (DOTATOC) possesses favorable characteristics for its potential therapeutic use in that it shows high affinity for sst(2), moderately high affinity for sst(5), and intermediate affinity for sst(3), high hydrophilicity, stable and facile labeling with (111)In and (90)Y. We began to investigate the potential therapeutic applications of (90)Y DOTATOC in 1997 by performing a thorough dosimetric study in 18 patients who were administered (111)In DOTATOC to estimate the absorbed doses during(90)Y-DOTATOC therapy. Then, we moved on and treated an overall number of 256 patients, mostly recruited in 2 distinct protocols with and without the administration of kidney protecting agents, with (90)Y DOTATOC. No major acute reactions were observed up to the activity of 5.55 GBq per cycle. The MTD per cycle was defined as 5.18 GBq. Objective therapeutic responses were documented in more than 20% of patients in terms of partial and complete responses. The present article reports in details our clinical experience (still ongoing) and outcomes with the use of (90)Y DOTATOC. Copyright 2002, Elsevier Science (USA). All rights reserved.

  9. IMMUNOHISTOCHEMICAL DETERMINATION OF EXPRESSION OF SOMATOSTATIN RECEPTORS TYPES 1, 2A, 3 AND 5 IN NEUROENDOCRINE TUMORS OF VARIOUS LOCALIZATION AND GRADE

    Directory of Open Access Journals (Sweden)

    L. E. Gurevich

    2016-01-01

    Full Text Available Background: Prediction of clinical benefits of somatostatin analogues in patients with neuroendocrine tumors (NET is very important prior to their administration. Data on immunohistochemical assessment of the expression of somatostatin receptors (SSR of various types, obtained from large samples of NET with various localization, functional activity and degree of malignancy, are scarce; therefore, the study was aimed at assessment of the latter.Materials and methods: We performed an immunohistochemical study with antibodies to SSR1, 2A, 3 and 5  types on tissue samples obtained during diagnostic and intra-operative biopsies from 399 NETs: 168 from pancreas, 120 from gastrointestinal tract (stomach, 48, from small intestine, 39, 14 of which being from duodenum; appendix, 6, colon and the rectum, 15 and 12, respectively, 84 from lung, 6 from thymus/mediastinum, and 21 from NET metastases of unknown primary localization.Results: Very high levels expression of receptors SSR2A preferentially binding to somatostatin analogues, which are currently used in clinical practice, were detected in the small intestine NETs (22/25, 88%, appendix (5/6, 83.3%, colon (10/15, 66.7%, thymus (4/6, 66.7%, atypical carcinoids of the lung (10/15, 66.7%, stomach (27/41, 65.8% and pancreas (105/165, 63.6%. The lowest expression was found in rectal NETs (5/12, 41.7% and small and large cell neuroendocrine lung carcinomas (20, 11.1%. Among functioning NETs, the highest level of SSR2A was found in gastrinomas (18/19, 94.7%, glucagonomas (15/16, 93.8%, small intestine carcinoids (31/35, 88.6%, and somatostatinomas (2/3, 66.7%. The lowest expression was detected in ACTH secreting tumors with Cushing's syndrome (11/12, 50%, and in insulinomas (34/69, 49.3%. SSR2A expression in functionally inactive pancreatic NETs was significantly higher than in insulinomas (57/82, 34/69 vs 69.5 and 49.3%, respectively. SSR2A expression was associated with the degree of malignancy and is

  10. The Comparison of Two Types of Treatment (High Dose and Low Dose IVIG in Children with GBS in Mofid Hospital

    Directory of Open Access Journals (Sweden)

    Parvaneh Karim-Zadeh

    2003-12-01

    Full Text Available Objective: Acute inflammatory demyelinating peripheral neuropathy (Guillain-Barre-Syndrome is by far the most common cause of immune–mediated peripheral nerve disease in children and with the near disappearance of poliomyelitis, is responsible for the great majority of cases of acute flaccid paralysis. Several controlled studies have done with corticosteroids, plasma pheresis and IVIG in pediatric patients. IVIG treatment can be done in two types of treatment: 1- High dose that means 1gr/kg/day for 2 days. 2- Low dose that means 400mg/kg/day for 5 days. Several studies in other countries have shown faster rate of recovery in patients who received total dose of IVIG in 2 days as opposed to 5 days. Materials & Methods: Because we have not any study about this two types of treatment in IRAN we decided to comparison this two types of IVIG treatment. So the patients that referred to Mofid children hospital for weakness and we diagnosed GBS (with history, physical examination, laboratories and EMG-NCV are divided in two groups: 1- High dose IVIG treatment (experimental group. 2- Low dose IVIG treatment (control group Then the results evaluated. Results: Our findings included that in high dose IVIG therapy we have faster rate of recovery and the Hospital stay is shorter than low dose IVIG-therapy. Also in this type of treatment “because the patients cure faster” , so complications are decreased in them. In the group of high dose IVIG therapy, lower and upper extremities weakness decreased in time. Conclusion: We did not receive any relationship between side effects of drugs and the type of treatment. The relationship between high dose IVIG therapy and drug side effects was not significant.

  11. High-dose Sulbactam Treatment for Ventilator-Associated Pneumonia Caused by Carbapenem-Resistant

    Directory of Open Access Journals (Sweden)

    In Beom Jeong

    2016-11-01

    Full Text Available Background Several antibiotics can be used to treat ventilator-associated pneumonia caused by carbapenem-resistant A. baumannii (CRAB-VAP including high-dose sulbactam. However, the effectiveness of high-dose sulbactam therapy is not well known. We report our experience with high-dose sulbactam for treatment of CRAB-VAP. Methods Medical records of patients with CRAB-VAP who were given high-dose sulbactam between May 2013 and June 2015 were reviewed. Results Fifty-eight patients with CRAB-VAP were treated with high-dose sulbactam. The mean age was 72.0 ± 15.2 years, and the acute physiology and chronic health evaluation II (APACHE II score was 15.1 ± 5.10 at the time of CRAB-VAP diagnosis. Early clinical improvement was observed in 65.5% of patients, and 30-day mortality was 29.3%. Early clinical failure (odds ratio [OR]: 8.720, confidence interval [CI]: 1.346-56.484; p = 0.023 and APACHE II score ≥ 14 at CRAB-VAP diagnosis (OR: 10.934, CI: 1.047-114.148; p = 0.046 were associated with 30-day mortality. Conclusions High-dose sulbactam therapy may be effective for the treatment of CRAB-VAP. However, early clinical failure was observed in 35% of patients and was associated with poor outcome.

  12. Somatostatin-expressing inhibitory interneurons in cortical circuits

    Directory of Open Access Journals (Sweden)

    Iryna Yavorska

    2016-09-01

    Full Text Available Cortical inhibitory neurons exhibit remarkable diversity in their morphology, connectivity, and synaptic properties. Here, we review the function of somatostatin-expressing (SOM inhibitory interneurons, focusing largely on sensory cortex. SOM neurons also comprise a number of subpopulations that can be distinguished by their morphology, input and output connectivity, laminar location, firing properties, and expression of molecular markers. Several of these classes of SOM neurons show unique dynamics and characteristics, such as facilitating synapses, specific axonal projections, intralaminar input, and top-down modulation, which suggest possible computational roles. SOM cells can be differentially modulated by behavioral state depending on their class, sensory system, and behavioral paradigm. The functional effects of such modulation have been studied with optogenetic manipulation of SOM cells, which produces effects on learning and memory, task performance, and the integration of cortical activity. Different classes of SOM cells participate in distinct disinhibitory circuits with different inhibitory partners and in different cortical layers. Through these disinhibitory circuits, SOM cells help encode the behavioral relevance of sensory stimuli by regulating the activity of cortical neurons based on subcortical and intracortical modulatory input. Associative learning leads to long-term changes in the strength of connectivity of SOM cells with other neurons, often influencing the strength of inhibitory input they receive. Thus despite their heterogeneity and variability across cortical areas, current evidence shows that SOM neurons perform unique neural computations, forming not only distinct molecular but also functional subclasses of cortical inhibitory interneurons.

  13. Mutational influences of low-dose and high let ionizing radiation in drosophila melanogaster

    Science.gov (United States)

    Lei, Huang; Fanjun, Kong; Sun, Yeqing

    For cosmic environment consists of a varying kinds of radiation particles including high Z and energy ions which was charactered with low-dose and high RBE, it is important to determine the possible biofuctions of high LET radiation on human beings. To analyse the possible effectes of mutational influences of low-dose and high-LET ionizing radiation, wild fruit flies drosophila melanogaster were irradiated by 12C6+ ions in two LET levels (63.3 and 30 keV/µum) with different low doses from 2mGy to 2000mGy (2, 20, 200, 2000mGy) in HIRFL (Heavy ion radiation facility laboratory, lanzhou, China).In the same LET value group, the average polymorphic frequency was elevated along with adding doses of irradation, the frequency in 2000 mGy dose samples was significantly higher than other samples (p<0.01).These results suggest that genomic DNA sequence could be effected by low-dose and high-LET ionizing radiation, the irradiation dose is an important element in genomic mutation frequency origination.

  14. Impact of the scintigraphy of somatostatin receptors upon the therapeutic strategy in patients bearing digestive endocrine tumors

    International Nuclear Information System (INIS)

    Lebtahi, R.; Cadiot, G.; Genin, R.; Delahaye, N.; Faraggi, M.; Daou, D.; Peker, C.; Migon, M.; Le Guludec, D.

    1997-01-01

    The scintigraphy of somatostatin receptors (SSR) is a sensible method for detecting the gastroenteric-pancreatic endocrine tumors and their metastases. The aim of this study is to evaluate the clinical impact of the results of SSR in taking patients in therapeutic charge. A hundred and sixty patients bearing biologically and/or histologically proved digestive endocrine tumors were prospectively studied. The patients were classified in 3 groups: group I - 90 patients with no known metastases; group II - 59 patients with liver metastases and group III - 11 patients with known extra-hepatic metastases. The results of the scintigraphy were compared with those of conventional imaging. The following results were obtained: in group 1 (90 patients) the conventional imaging has allowed detecting 53 primitive tumors in 44 patients. The SSR visualized 68% of these sites and has detected 26 supplementary primitive sites in 20 patients and 29 metastatic sites in 25 patients. In group II the scintigraphy has detected 95% of hepatic metastases and revealed 23 new metastasis sites and 18/59 patients. In group III the scintigraphy has detected 11 new sites in 7 patients. The results of scintigraphy modified the patient's classification in 38 cases (24%). The therapeutic strategy was modified for 40 patients (25%). In conclusion, the scintigraphy of somatostatin receptors is able to detect a significant number of digestive endocrine tumors what has important implications for therapeutical planning of the treatment of patients. It must be carried out during pre-therapeutic extension examination of these tumors

  15. Global dose to man from proposed NNTRP high altitude nuclear tests

    International Nuclear Information System (INIS)

    Peterson, K.R.

    1975-05-01

    Radionuclide measurements from past high altitude nuclear testing have enabled development of a model to estimate surface deposition and doses from 400 kt of fission products injected in winter within the Pacific Test Area at altitudes in excess of 50 km. The largest 30-year average dose to man is about 10 millirem and occurs at 30 0 to 50 0 N latitude. The principal contributor to this dose is external gamma radiation from gross fission products. Individual doses from 90 Sr via the forage-cow-milk pathway and 137 Cs via the pasture-meat pathway are about 1/5 the gross fission product doses. The global 30-year population dose is 3 x 10 7 person-rem, which compares with a 30-year natural background population dose of 1 X 10 10 person-rem. Due in large part to the global distribution of population, over 98 percent of the global person-rem from the proposed high altitude tests is received in the Northern Hemisphere, while about 75 percent of the total population dose occurs within the 30 0 --50 0 N latitude belt. Detonations in summer would decrease the global dose by about a factor of three. (U.S.)

  16. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    Science.gov (United States)

    Jaccard, Maud; Petersson, Kristoffer; Buchillier, Thierry; Germond, Jean-François; Durán, Maria Teresa; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François O; Bailat, Claude

    2017-02-01

    The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋ m ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋ p ) of up to 8 × 10 6 Gy/s. To do this, we evaluated the overall uncertainties in EBT3 film dosimetry as well as the energy and dose-rate dependence of their response. Our dosimetric system was composed of EBT3 Gafchromic films in combination with a flatbed scanner and was calibrated against an ionization chamber traceable to primary standard. All sources of uncertainties in EBT3 dosimetry were carefully analyzed using irradiations at a clinical radiotherapy linac. Energy dependence was investigated with the same machine by acquiring and comparing calibration curves for three different beam energies (4, 8 and 12 MeV), for doses between 0.25 and 30 Gy. Ḋ m dependence was studied at the clinical linac by changing the pulse repetition frequency (f) of the beam in order to vary Ḋ m between 0.55 and 4.40 Gy/min, while Ḋ p dependence was probed at the prototype machine for Ḋ p ranging from 7 × 10 3 to 8 × 10 6 Gy/s. Ḋ p dependence was first determined by studying the correlation between the dose measured by films and the charge of electrons measured at the exit of the machine by an induction torus. Furthermore, we compared doses from the films to independently calibrated thermo-luminescent dosimeters (TLD) that have been reported as being dose-rate independent up to such high dose-rates. We report that uncertainty below 4% (k = 2) can be achieved in the dose range between 3 and 17 Gy. Results also demonstrated that EBT3 films did not display any detectable energy dependence for electron beam energies between 4 and 12 MeV. No Ḋ m dependence was found either. In addition, we obtained excellent consistency between films and TLDs over the entire Ḋ p

  17. Oval pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    Hoogendijk, JE; Wokke, JHJ; de Visser, M

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Sis patients responded. Side effects

  18. Oral pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    van der Meulen, M. F.; Hoogendijk, J. E.; Wokke, J. H.; de Visser, M.

    2000-01-01

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Six patients responded. Side effects

  19. High-dose acetylcysteine in idiopathic pulmonary fibrosis

    NARCIS (Netherlands)

    Demedts, Maurits; Behr, Juergen; Buhl, Roland; Costabel, Ulrich; Dekhuijzen, Richard; Jansen, Henk M.; MacNee, William; Thomeer, Michiel; Wallaert, Benoit; Laurent, François; Nicholson, Andrew G.; Verbeken, Eric K.; Verschakelen, Johny; Flower, Christopher D. R.; Capron, Frédérique; Petruzzelli, Stefano; de Vuyst, Paul; van den Bosch, Jules M. M.; Rodriguez-Becerra, Eulogio; Corvasce, Giuseppina; Lankhorst, Ida; Sardina, Marco; Montanari, Mauro

    2005-01-01

    BACKGROUND Idiopathic pulmonary fibrosis is a chronic progressive disorder with a poor prognosis. METHODS We conducted a double-blind, randomized, placebo-controlled multicenter study that assessed the effectiveness over one year of a high oral dose of acetylcysteine (600 mg three times daily) added

  20. Regular self-microstructuring on CR39 using high UV laser dose

    International Nuclear Information System (INIS)

    Parvin, P.; Refahizadeh, M.; Mortazavi, S.Z.; Silakhori, K.; Mahdiloo, A.; Aghaii, P.

    2014-01-01

    The UV laser induced replicas in the form of self-lining microstructures are created by high dose (with high fluence) ArF laser irradiation on CR39. Microstructures as the self-induced contours, in the form of concentric circles, appear when the laser fluence is well above the ablation threshold. It leads to the regular periodic parallel lines, i.e. circles with large radii having spatial separation 100–200 nm and line width 300–600 nm, where the number of shots increases to achieve higher UV doses. The surface wettability is also investigated after laser texturing to exhibit that a notable hydrophilicity takes place at high doses.

  1. High-dose myeloablative versus conventional low-dose radioimmunotherapy (RIT) of mantle cell lymphoma (MCL) with the chimeric anti-CD20 antibody C2B8

    International Nuclear Information System (INIS)

    Behr, T.M.; Gotthardt, M.; Schipperm, M.L.; Gratz, S.; Behe, M.P.; Brittinger, G.; Woermann, B.; Becker, W.

    2002-01-01

    CD20 has been used as target molecule for low-dose as well as high-dose, myeloablative RIT of B-cell NHL. MCL is an especially aggressive, prognostically unfavorable form of B-cell NHL. The aim of this study was to investigate whether high-dose, myeloablative RIT with the 131 I-labeled chimeric anti-CD20 antibody C2B8 (rituxan, Mabthera, Roche) may be therapeutically more effective than conventional low-dose therapy in MCL. A total of twelve patients with chemorefractory or relapsed mantle cell lymphoma were studied so far (all of them having relapsed after high-dose chemotherapy, seven of them combined with 12 Gy TBI). A diagnostic-dosimetric study was performed with 10 mCi of 131 I-C2B8 at a protein dose of 2.5 mg/kg. In case of splenic pooling, the protein dose was increased until a more 'favorable' biodistribution was obtained. Therapy was performed with conventional (30-75 mCi; n=4) or myeloablative activities (261-515 mCi; n=8) of 131 I-C2B8 at the previously optimized protein dose, aiming at whole-body doses of ≤ 0.8 Gy (for low-dose RIT) or lung doses of ≤ 27 Gy (for high-dose RIT). Clinical follow-up was obtained for up to 42 months. Overall, in 11 patients the 2.5 mg/kg protein dose was used, whereas in one patient with marked splenomegaly, 10 mg/kg were necessary to overcome the splenic antigenic sink. In the high-dose patients, non-hematologic toxicity was restricted to mild to moderate nausea, fever, transient bilirubin or liver enzyme elevations. Despite thyroid blocking, 6/8 high-dose (in contrast to 0/4 low-dose) patients developed hypothyroidism, requiring thyroxine substitution at 6-18 months after RIT. The response rate in the low-dose arm was only 1(PR)/4, whereas 7/8 high-dose patients experienced complete and the remainder a partial remission. 6 high-dose patients are still in CR (one of them relapsed locally at 3 months, one systemically at 26 months after RIT), and 7 are still alive for up to 42+ months. In contrast to low-dose therapy

  2. Regulatory Forum Opinion Piece*: Retrospective Evaluation of Doses in the 26-week Tg.rasH2 Mice Carcinogenicity Studies: Recommendation to Eliminate High Doses at Maximum Tolerated Dose (MTD) in Future Studies.

    Science.gov (United States)

    Paranjpe, Madhav G; Denton, Melissa D; Vidmar, Tom J; Elbekai, Reem H

    2015-07-01

    High doses in Tg.rasH2 carcinogenicity studies are usually set at the maximum tolerated dose (MTD), although this dose selection strategy has not been critically evaluated. We analyzed the body weight gains (BWGs), mortality, and tumor response in control and treated groups of 29 Tg.rasH2 studies conducted at BioReliance. Based on our analysis, it is evident that the MTD was exceeded at the high and/or mid-doses in several studies. The incidence of tumors in high doses was lower when compared to the low and mid-doses of both sexes. Thus, we recommend that the high dose in male mice should not exceed one-half of the estimated MTD (EMTD), as it is currently chosen, and the next dose should be one-fourth of the EMTD. Because females were less sensitive to decrements in BWG, the high dose in female mice should not exceed two-third of EMTD and the next dose group should be one-third of EMTD. If needed, a third dose group should be set at one-eighth EMTD in males and one-sixth EMTD in females. In addition, for compounds that do not show toxicity in the range finding studies, a limit dose should be applied for the 26-week carcinogenicity studies. © 2014 by The Author(s).

  3. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  4. TL response of citrine samples for high-dose dosimetry

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2011-01-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the thermoluminescence technique (TL). In this work, the TL properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tectosilicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The citrine stone samples were powdered, and the selected grains were mixed with Teflon in the proportion 2 (Teflon):1 (Citrine). The mixture was pressed and sintered for production of Citrine -Teflon pellets of 50 mg. The TL emission curve showed two peaks at 160 deg C and 220 deg C. To remove the TL peak (160 deg C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The TL dose-response curve between 50 Gy and 100 kGy, the reproducibility of TL response and the lower detection dose were obtained. The preliminary results show that citrine may be useful for high-dose dosimetry. (author)

  5. Moderate- vs high-dose methadone in the treatment of opioid dependence: a randomized trial.

    Science.gov (United States)

    Strain, E C; Bigelow, G E; Liebson, I A; Stitzer, M L

    1999-03-17

    Methadone hydrochloride treatment is the most common pharmacological intervention for opioid dependence, and recent interest has focused on expanding methadone treatment availability beyond traditional specially licensed clinics. However, despite recommendations regarding effective dosing of methadone, controlled clinical trials of higher-dose methadone have not been conducted. To compare the relative clinical efficacy of moderate- vs high-dose methadone in the treatment of opioid dependence. A 40-week randomized, double-blind clinical trial starting in June 1992 and ending in October 1995. Outpatient substance abuse treatment research clinic at the Johns Hopkins University Bayview Campus, Baltimore, Md. One hundred ninety-two eligible clinic patients. Daily oral methadone hydrochloride in the dose range of 40 to 50 mg (n = 97) or 80 to 100 mg (n = 95), with concurrent substance abuse counseling. Opioid-positive urinalysis results and retention in treatment. By intent-to-treat analysis through week 30 patients in the high-dose group had significantly lower rates of opioid-positive urine samples compared with patients in the moderate-dose group (53.0% [95% confidence interval [CI], 46.9%-59.2%] vs 61.9% [95% CI, 55.9%-68.0%]; P = .047. These differences persisted during withdrawal from methadone. Through day 210 no significant difference was evident between dose groups in treatment retention (high-dose group mean retention, 159 days; moderate-dose group mean retention, 157 days). Nineteen (33%) of 57 patients in the high-dose group and 11 (20%) of 54 patients in the moderate-dose group completed detoxification. Both moderate- and high-dose methadone treatment resulted in decreased illicit opioid use during methadone maintenance and detoxification. The high-dose group had significantly greater decreases in illicit opioid use.

  6. High dose vitamin D may improve lower urinary tract symptoms in postmenopausal women.

    Science.gov (United States)

    Oberg, Johanna; Verelst, Margareta; Jorde, Rolf; Cashman, Kevin; Grimnes, Guri

    2017-10-01

    Lower urinary tract symptoms (LUTS) are common in postmenopausal women, and have been reported inversely associated with vitamin D intake and serum 25-hydroxyvitamin D (25(OH)D) levels. The aim of this study was to investigate if high dose vitamin D supplementation would affect LUTS in comparison to standard dose. In a randomized controlled study including 297 postmenopausal women with low bone mineral density, the participants were allocated to receive capsules of 20 000IU of vitamin D 3 twice a week (high dose group) or similar looking placebo (standard dose group). In addition, all the participants received 1g of calcium and 800IU of vitamin D daily. A validated questionnaire regarding LUTS was filled in at baseline and after 12 months. At baseline, 76 women in the high dose group and 82 in the standard dose group reported any LUTS. Levels of serum 25(OH)D increased significantly more in the high dose group (from 64.7 to 164.1nmol/l compared to from 64.1 to 81.8nmol/l, p<0.01). No differences between the groups were seen regarding change in LUTS except for a statistically significant reduction in the reported severity of urine incontinence in the high dose group as compared to the standard dose group after one year (p<0.05). The results need confirmation in a study specifically designed for this purpose. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Identification of the receptors for somatostatin (SST) and cortistatin (CST) in chickens and investigation of the roles of cSST28, cSST14, and cCST14 in inhibiting cGHRH1-27NH2-induced growth hormone secretion in cultured chicken pituitary cells.

    Science.gov (United States)

    Meng, Fengyan; Huang, Guian; Gao, Shunyu; Li, Juan; Yan, Zhenxin; Wang, Yajun

    2014-03-25

    Somatostatin receptors (SSTRs) are proposed to mediate the actions of somatostatin (SST) and its related peptide, cortistatin (CST), in vertebrates. However, the identity, functionality, and tissue expression of these receptors remain largely unknown in most non-mammalian vertebrates including birds. In this study, five SSTRs (named cSSTR1, cSSTR2, cSSTR3, cSSTR4, cSSTR5) were cloned from chicken brain by RT-PCR. Using a pGL3-CRE-luciferase reporter system, we demonstrated that activation of each cSSTR expressed in CHO cells by cSST28, cSST14 and cCST14 treatment could inhibit forskolin-induced luciferase activity of CHO cells, indicating the functional coupling of all cSSTRs to Gi protein(s). Interestingly, cSSTR1-4 expressed in CHO cells could be activated by cSST28, cSST14 and cCST14 with high potencies, suggesting that they may function as the receptors common for these peptides. In contrast, cSSTR5 could be potently activated by cSST28 only, indicating that it is a cSST28-specific receptor. Using RT-PCR, wide expression of cSSTRs was detected in chicken tissues including pituitary. In accordance with their expression in pituitary, cSST28, cSST14, and cCST14 were demonstrated to inhibit basal and novel cGHRH1-27NH2-induced GH secretion in cultured chicken pituitary cells dose-dependently (0-10nM) by Western blot analysis, suggesting the involvement of cSSTR(s) common for these peptides in mediating their inhibitory actions. Collectively, our study establishes a molecular basis to elucidate the roles of SST/CST in birds and provide insights into the roles of SST/CST in vertebrates, such as their conserved actions on pituitary. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Radiation processing and high-dose dosimetry at ANSTO

    International Nuclear Information System (INIS)

    Gant, G.J.; Saunders, M.; Banos, C.; Mo, L.; Davies, J.; Evans, O.

    2001-01-01

    The Radiation Technology group at ANSTO is part of the Physics Division and provides services and advice in the areas of gamma irradiation and high-dose dosimetry. ANSTO's irradiation facilities are designed for maximum dose uniformity and provide a precision irradiation service unique in Australia. Radiation Technology makes and sells reference and transfer standard dosimeters which are purchased by users and suppliers of commercial irradiation services in Australia and the Asia-Pacific region. A calibration service is also provided for dosimeters purchased from other suppliers

  9. Safety of high-dose daptomycin in patients with severe renal impairment

    Directory of Open Access Journals (Sweden)

    Tai CH

    2018-03-01

    Full Text Available Chih-Hsun Tai,1 Chi-Hao Shao,2 Chen-You Chen,2 Shu-Wen Lin,1–3 Chien-Chih Wu1,2 1Department of Pharmacy, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan; 2School of Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan; 3Graduate Institute of Clinical Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan Background: Treatment options are limited for infections due to multidrug-resistant Gram-positive pathogens. Daptomycin is a lipopeptide antibiotic with concentration-dependent killing characteristic and dose-dependent post-antibiotic effect. To achieve optimized pharmacodynamic effect, some experts advocated using a high dose of daptomycin (≥9 mg/kg for severe infections. However, the safety of high-dose therapy in patients with renal impairment remains unknown. This study was aimed to evaluate the safety of daptomycin in patients with severe renal impairment. Methods: This was a retrospective study performed by reviewing electronic medical records. Patients with severe renal impairment who were treated with daptomycin in a tertiary teaching hospital between January 1, 2013, and June 30, 2016, were included for evaluation. The incidence rates of creatine kinase (CK elevation between high-dose (≥9 mg/kg and standard-dose (<9 mg/kg groups were compared. Results: Overall, 164 patients met the inclusion criteria, and 114 (69.5% of them were on renal replacement therapy. Vancomycin-resistant enterococci were the most common pathogens (61.3% of the patients with documented pathogens. The treatment success rate was 51.6% in the 91 patients with bacteremia. The average dose of daptomycin was 8.0±2.3 mg/kg, and 37 (22.6% patients received ≥9 mg/kg. CK levels were followed in 108 (65.9% patients. Significantly higher incidence of CK elevation was found in the high-dose group compared with that in the standard-dose group (10.8% vs 1.6%, P<0.05. Moreover

  10. Unusual complication and successful high-dose chemotherapy ...

    African Journals Online (AJOL)

    ... treated with high-dose chemotherapy in our institution, complicated by unusual bilateral renal vein tumour thrombi and tumour lysis syndrome. We believe this unique case highlights the need for early recognition of current and potential complications on staging computed tomography imaging, as well as successful use of ...

  11. Efecto hemodinámico esplácnico de somatostatina y octreótido en cirróticos: Estudio con ultrasonografía Doppler Splanchnic hemodynamic effects of somatostatin and octreotide in cirrhotic patients: A Doppler ultrasonographic study

    Directory of Open Access Journals (Sweden)

    F. J. Fernández Pérez

    2008-09-01

    .18 vs. +6.16% from baseline (p < 0.05. These changes were already evident at 15 minutes and remained unchanged over the study period. With respect to OCT, SOM caused a higher reduction in mean velocity and flow in the portal vein, with no significant differences for congestion index and mesenteric artery resistivity index, both increased by SOM and OCT. Plasma bradykinine and VIP concentrations remained unchanged in the three groups. Conclusions: at therapeutic doses, intravenous somatostatin and octreotide reduce portal vein velocity and flow, and increase portal vein congestion index and superior mesenteric artery resistivity index. Somatostatin causes a higher portal flow reduction than octreotide in spite of a similar splanchnic arterial effect.

  12. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.; Castro, J.R.; Chen, G.T.Y.; Collier, J.M.; Cartigny, A.; Blakely, E.A.; Lyman, J.T.; Zink, S.R.

    1985-02-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons.

  13. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    International Nuclear Information System (INIS)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.

    1985-01-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons

  14. Low dose rate and high dose rate intracavitary treatment for cervical cancer

    International Nuclear Information System (INIS)

    Hareyama, Masato; Oouchi, Atsushi; Shidou, Mitsuo

    1997-01-01

    From 1984 through 1993, 144 previous untreated patients with carcinoma of uterine cervix were treated with either low dose rate 137 Cs therapy (LDR) or high dose rate 60 Co therapy (HDR). The local failure rates for more than 2-years for the primary lesions were 11.8% (8 of 63 patients) for LDR and 18.0% (11 of 61 patients). Rectal complication rates were significantly lower for HDR versus LDR (14.3% VS. 32.8%. p<0.01). Also, bladder complication rates were significantly lower for HDR versus LDR (0% VS. 10.4%, p<0.005). Treatment results in term of local control were equivalent for HDR and LDR treatment. However, the incidence of complications was higher for the LDR group than for the HDR group. (author)

  15. Dimethyl sulfoxyde diethyl fumarate solution for high dose dosimetry

    International Nuclear Information System (INIS)

    Al-Kassiri, H.; Kattan, M.; Daher, Y.

    2007-06-01

    Dosimetric characterization of diethyl fumarate DEF in dimethyl sulfoxyde DMSO solution has been studied spectrophotometrically for possible application at high dose radiation dosimetry in the range (0-225 kGy). The absorption spectra of irradiated solution showed broad absorption bands between (325-400 nm) with a shoulder at 332 nm. The absorption increases as the dose is increased. Absorbance at 332 nm were measured and plotted against absorbed dose. Linear relationship and good response were found between absorbed dose and absorbance of 20% DEF concentration in the range (0-225 kGy) at the wave length, and linearity up to 250 kGy of absorbance at 332 nm .Good dose rate independence was observed in the range (14-33 kGy/h). The effect of post irradiation storage in darkness and indirect daylight conditions were not found to influence the absorption up to 700 h after irradiation. The effect of irradiation temperature within the range (0 to 60 centigrade degree) on the dosimetry performance was discussed.(author)

  16. [Construction and immunogenicity of recombinant porcine parvovirus-like particles with somatostatin].

    Science.gov (United States)

    Zhang, Xuehua; Zheng, Qisheng; Chen, Jin; Xue, Gang; Hou, Hongyan; Hou, Jibo

    2010-08-01

    In order to obtain a virus-like particle vaccine both for porcine parvovirus (PPV) prevention and growth-promotion, VP2 gene of PPV NJ-a strain was amplified with PCR, and four copies of synthetic somatostatin gene were fused to the N-terminal of VP2 gene. The fused gene was cloned into pFast-HT A to construct the recombinant plasmid pFast-SS4-VP2, then the pFast-SS4-VP2 was transformed into DH10Bac competent cells and recombined with shuttle vector Bacmid, followed by identification with blue-white screening and PCR analysis for three cycles, and the positive recombinant was named as rBacmid-SS4-VP2. The positive Sf-9 cells were transfected with rBacmid-SS4-VP2 by Lipofectamine to produce recombinant baculovirus. When the cytopathic effect (CPE) was obvious, the transfected Sf-9 cell was harvested, and the positive recombinant virus was named as rBac-SS4-VP2. The insertion for the target gene into baculovirus genome was confirmed with PCR. SDS-PAGE and Western blotting revealed that the calculated protein of approximately 68 kDa was in the expressed in the insect cells. The Sf-9 cells infected with rBac-SS4-VP2 were stained positive against PPV antibody using the indirect immunofluorescence assay (IFA). Moreover, the virus particle self-assembly was observed under electron microscopy. 90 four-week-old mice were immunized by the recombinant protein coupled with different adjuvants alhydrogel, IMS and oil. VP2-specific ELISA antibodies, PPV-specific neutralizing antibody, somatostatin antibody and growth hormone levels were examined to evaluate the immunogenicity of this virus like particle. Results indicated that mice groups immunized rSS4-VP2 protein with alhydrogel and IMS developed similar humoral immune response comparing with inactived PPV vaccine. Mice group immunized with rSS4-VP2 generated higher level of SS antibody and growth hormone comparing with negative control, mice receiving rSS4-VP2 with alhydrogel developed the highest antibody titre than all

  17. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  18. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tome, Wolfgang A. [Department of Human Oncology, University of Wisconsin-Madison, WI, 53792 (United States); Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC 3002 (Australia) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Human Oncology, University of Wisconsin-Madison, WI 53792 (United States); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia) and Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur (Malaysia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Einstein Institute of Oncophysics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York 10461 (United States) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2012-08-15

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  19. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tomé, Wolfgang A.

    2012-01-01

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed “Super Sampling” involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  20. The influence of high doses of radiation in citrine stones

    International Nuclear Information System (INIS)

    Teixeira, M. I.; Caldas, L. V. E.

    2014-08-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  1. The influence of high doses of radiation in citrine stones

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M. I. [Universidade Nove de Julho - UNINOVE, Rua Vergueiro 235/249, 01504-001 Sao Paulo (Brazil); Caldas, L. V. E., E-mail: miteixeira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ({sup 60}Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO{sub 2}), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  2. Review of high-dose intravenous vitamin C as an anticancer agent.

    Science.gov (United States)

    Wilson, Michelle K; Baguley, Bruce C; Wall, Clare; Jameson, Michael B; Findlay, Michael P

    2014-03-01

    In the 1970s, Pauling and Cameron reported increased survival of patients with advanced cancer treated with high-dose intravenous (IV) vitamin C (L-ascorbate, ascorbic acid). These studies were criticized for their retrospective nature and lack of standardization of key prognostic factors including performance status. Subsequently, several well-designed randomized controlled trials failed to demonstrate a significant survival benefit, although these trials used high-dose oral vitamin C. Marked differences are now recognized in the pharmacokinetics of vitamin C with oral and IV administration, opening the issue of therapeutic efficacy to question. In vitro evidence suggests that vitamin C functions at low concentrations as an antioxidant but may have pro-oxidant activity at high concentrations. The mechanism of its pro-oxidant action is not fully understood, and both intra- and extracellular mechanisms that generate hydrogen peroxide have been proposed. It remains to be proven whether vitamin C-induced reactive oxygen species occur in vivo and, if so, whether this will translate to a clinical benefit. Current clinical evidence for a therapeutic effect of high-dose IV vitamin C is ambiguous, being based on case series. The interpretation and validation of these studies is hindered by limited correlation of plasma vitamin C concentrations with response. The methodology exists to determine if there is a role for high-dose IV vitamin C in the treatment of cancer, but the limited understanding of its pharmacodynamic properties makes this challenging. Currently, the use of high-dose IV vitamin C cannot be recommended outside of a clinical trial. © 2014 Wiley Publishing Asia Pty Ltd.

  3. Conventional-Dose versus High-Dose Chemotherapy for Relapsed Germ Cell Tumors

    Directory of Open Access Journals (Sweden)

    Deaglan J. McHugh

    2018-01-01

    Full Text Available The majority of metastatic germ cell tumors (GCTs are cured with cisplatin-based chemotherapy, but 20–30% of patients will relapse after first-line chemotherapy and require additional salvage strategies. The two major salvage approaches in this scenario are high-dose chemotherapy (HDCT with autologous stem cell transplant (ASCT or conventional-dose chemotherapy (CDCT. Both CDCT and HDCT have curative potential in the management of relapsed/refractory GCT. However, due to a lack of conclusive randomized trials, it remains unknown whether sequential HDCT or CDCT represents the optimal initial salvage approach, with practice varying between tertiary institutions. This represents the most pressing question remaining for defining GCT treatment standards and optimizing outcomes. The authors review prognostic factors in the initial salvage setting as well as the major studies assessing the efficacy of CDCT, HDCT, or both, describing the strengths and weaknesses that formed the rationale behind the ongoing international phase III “TIGER” trial.

  4. Somatostatin analogues labelled with 99mTc

    International Nuclear Information System (INIS)

    Obenaus, E.; Crudo, J.; Edreira, M.; Viaggi, M.; De Castiglia, S.G.

    2001-01-01

    The aim of the present work was to study the biological and radiochemical behaviour of two somatostatin analogues, the RC-160 and Tyr3Octreotide(TOC) peptides when labelling with 99m Tc by two methods: direct and indirect using S-benzoyl- mercaptoacetyl triglycine (MAG-3) and hydrazinonicotinamide (HYNIC) as chelating agents. RC-160 was labelled with 125I (30% labelling yield) in order to examine its receptor specificity and to study the biodistribution in normal animals. A total binding of 30% and a non specific binding lower than 10% was obtained. On the other hand, the RC-160 was labelled with 99m Tc by a direct method (70% labelling yield), using sodium ascorbate and dithionite in order to reduce the peptide and 99m Tc, respectively. The synthesis of RC-160 with S-benzoyl MAG-3 and TOC with HYNIC, for labelling with 99m Tc are also described. The conjugates were prepared on a small scale and labelled with the radionuclide using tricine as co-ligands for HYNIC conjugates. Chromatographic studies were performed using HPLC system and radiochemical purities higher than 75% and 95% were obtained respectively. Biodistributions studies in normal Wistar rats were performed and results were correlated with chromatographic and protein binding properties. Lower lipophilicity of the labelled conjugates resulted in a higher renal excretion. HYNIC-TOC complex showed promising results when labelling with 99m Tc using tricine as co-ligand although higher stability should be found for ternary co-ligands compared to tricine. (author)

  5. Low- and high-dose laser irradiation effects on cell migration and destruction

    Science.gov (United States)

    Layton, Elivia; Gallagher, Kyra A.; Zukerman, Sara; Stevens, Brianna; Zhou, Feifan; Liu, Hong; Chen, Wei R.

    2018-02-01

    Metastases are the cause of more than 90 percent of cancer-related deaths. Current treatment methods, including chemotherapy, radiation, and surgery, fail to target the metastases effectively. One potential treatment for metastatic cancer is laser immunotherapy (LIT). LIT combines the use of a photothermal laser with an immunoadjuvant, Glycated Chitosan (GC). GC combined with single-walled carbon nanotubes (SWNTs) has proven to be a viable alternative to traditional cancer treatment methods, when under irradiation of laser with appropriate wavelength. In this study, the effects of low dose and high dose laser irradiation on metastatic pancreatic cancer cell migration were observed. It was found that low dose irradiation increased the migration rate, but the high dose irradiation significantly decreased the migration rate of the cancer cells. When using LIT, the goal is to kill tumor cells and to prompt the correct immune response. If the tumor were irradiated with a low dose, it would promote metastasis. If the dose of irradiation were too high, it would destroy the entire tumor and the immune response would not recognize the tumor. Therefore, the laser dose plays an important role in LIT, particularly when using SWNT as light absorbing agent. Our results from this study will delineate the optimal laser irradiation dose for destroying tumor cells and at the same time preserve and release tumor antigens as a precursor of antitumor immune response.

  6. A 12-month phase 3 study of pasireotide in Cushing's disease

    DEFF Research Database (Denmark)

    Colao, Annamaria; Petersenn, Stephan; Newell-Price, John

    2012-01-01

    Cushing's disease is associated with high morbidity and mortality. Pasireotide, a potential therapy, has a unique, broad somatostatin-receptor-binding profile, with high binding affinity for somatostatin-receptor subtype 5.......Cushing's disease is associated with high morbidity and mortality. Pasireotide, a potential therapy, has a unique, broad somatostatin-receptor-binding profile, with high binding affinity for somatostatin-receptor subtype 5....

  7. High-dose radioiodine therapy of Graves disease

    International Nuclear Information System (INIS)

    Solodky, V.; Fomin, D.; Pestritskaya, E.

    2015-01-01

    Full text of publication follows. Objectives: to estimate the effectiveness and safety of the disease treatment under different modes of applying RIT. Materials and methods: 67 patients with the thyrotoxicosis condition associated with Graves disease were researched. The patients were divided into 2 groups: a control group with 25 people (18 women and 7 men), who underwent a low-dose therapy of 150-500 MBq; and a main group of 42 people (32 women and 10 men), who underwent a high-dose therapy of 550 and 800 MBq. The volume of thyroid prior to the treatment made up 23.8 ± 20 ml in the main group and 30.2 ± 23 ml in the control one. The average age in the high-dose group was 44.6 ±23 years old and in the low-dose -47.2 ± 24 years old. In terms of the hormone level before the RIT, 52% of the main group patients experienced euthyroidism, while 48% - thyrotoxicosis. The corresponding indices in the control group were 42% and 58% respectively. The cessation of the thyreostatic therapy came on 5. to 21. day prior to the treatment, with the average of 14 ±7 days in both groups. The diagnosis of the disease was based on ultrasonography, planar scintigraphy, the hormone level and antibody titer. The performance was assessed through the attainment of hypo-thyrosis and the transition to a substitutive hormonal therapy with L-thyroxine in 6 months or more. The attainment of euthyroidism was seen as a partial effect due to a possibility of relapse. Results: in 6 months a positive result in the form of hypo-thyrosis was achieved for 39 patients in the main group, which accounted for 93%, and 3 patients (7%) experienced euthyroidism. No symptomatic thyrotoxicosis relapses were revealed. In the control group, hypo-thyrosis was achieved by 18 patients, which accounted for 72%; euthyroidism came up to 12%; 4 patients needed a refresher course of RIT, which made up 16% of the group. 93% of the main group patients tolerated the treatment favourably. 3 patients complained of the

  8. Establishment of a dosimetric system for high doses using glasses

    International Nuclear Information System (INIS)

    Correa Quezada, Valeria de la Asuncion

    1997-01-01

    A routine dosimetric system was developed using commercial glass samples. The dosimetric characteristics of national and imported samples were studied: batch uniformity, response repeatability, reutilization, absorbed dose response, detection range, response stability as a function of absorbed dose, storage temperature and thermal treatments pre- and post-irradiation, using the optical absorption technique. As an application, the dosimetric system was tested in a flower irradiation process at IPEN. All the obtained results show the usefulness of the proposed system for high dose dosimetry. (author)

  9. Implementation of high-dose chemical dosimetry for industrial facilities

    International Nuclear Information System (INIS)

    Conceicao, Cirilo Cezar Sant'Anna da

    2006-01-01

    The purpose of this work is the implementation of methodology for high dose measurements using chemical dosimeters in liquid phase, traceable to the international metrology system, and make available in the country, the standard of high-dose to industrial irradiation facilities and research irradiators, trough the quality program with comparative measurements and direct use of the standard dosimeters in routine. The use of these low cost dosimetry systems in industrial irradiation facilities, assists to the certification requirements and it can reduce the costs with dosimetry for approximately 20% of the total dosimetry costs, using these systems in routine measurements and validation process, largely substituting the imported PMMA dosimeters, among others. (author)

  10. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Ming; Zhang, Qilin [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Shanghai (China); Shanghai Pituitary Tumor Center, Shanghai (China); Liu, Wenjuan; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yang, Yeping [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Endocrinology and Metabolism, Huashan Hospital, Shanghai Medical College, Shanghai (China); Wang, Meng [Fudan University, Department of Endocrinology and Metabolism, Huashan Hospital, Shanghai Medical College, Shanghai (China); Soochow University, Division of Endocrinology, the Second Affiliated Hospital, Suzhou (China); Zhu, Jingjing [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Neuropathology, Huashan Hospital, Shanghai Medical College, Shanghai (China); Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Zhao, Yao; Wang, Yongfei [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Shanghai (China); Shanghai Pituitary Tumor Center, Shanghai (China); Yao, Zhenwei [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Radiology, Huashan Hospital, Shanghai Medical College, Shanghai (China); Lu, Yun [Fudan University, Department of Nuclear Medicine, Huashan Hospital, Shanghai Medical College, Shanghai (China)

    2016-11-15

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly. (orig.)

  11. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly

    International Nuclear Information System (INIS)

    Shen, Ming; Zhang, Qilin; Liu, Wenjuan; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yang, Yeping; Wang, Meng; Zhu, Jingjing; Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Zhao, Yao; Wang, Yongfei; Yao, Zhenwei; Lu, Yun

    2016-01-01

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly. (orig.)

  12. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly.

    Science.gov (United States)

    Shen, Ming; Zhang, Qilin; Liu, Wenjuan; Wang, Meng; Zhu, Jingjing; Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yao, Zhenwei; Lu, Yun; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Yang, Yeping; Zhao, Yao; Wang, Yongfei

    2016-11-01

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly.

  13. Labelling and quality control of somatostatin analogues with 99mTc

    International Nuclear Information System (INIS)

    Verdera, S.; Balter, H.; Rodriguez, G.; Robles, A.; Oliver, P.; Laiz, J.; Souto, B.

    2001-01-01

    Techniques and methodologies for labelling peptides with 99m Tc and methods for their purification, chemical, radiochemical and biological controls were evaluated. With the purpose of gaining experience, labelling with 125 I was also studied. RC-160 was labelled with 125 I using iodogen as well as chloramine-T method. Higher yields were obtained with chloramine-T method (60%), rendering 125 I-peptide with 98% of radiochemical purity, with specific activity of 240 μCi/μg - 274 μCi/μg. The product was stable for five weeks (at -20 deg. C). For somatostatin receptors studies rat brain cortex membrane was prepared. Maximum binding capacity was 24.7% and Kaff for the binding of RC-160 to receptor was estimated as 2.0x10 10 M -1 . Other peptides as β-(2-Naphthyl)- D Ala-Cys-Tyr- D Trp-Lys-Val-Cys-Thr amide (N-9642, Σ) and mouse epidermal growth factor (mEGF) were also labelled by means of limiting chloramine-T method. In case of mEGF the availability of membrane receptors allowed us to experiment in mice as well as in vitro. The reaction yields were up to 60% and 70% respectively. Biodistribution of 125 I-mEGF in a mouse with adenoma demonstrated preferential uptake in tumour (21,7% injected dose). The radioimmunoassay system gave 39% maximum binding (MB) and 50% displacement (ED 50 ) for 10 ng/mL unlabelled mEGF. Direct method and BFC's for labelling peptides with 99m Tc were investigated and purification and quality controls studies were performed by TLC, HPLC (UV and gamma detection). RC-160 was labelled by a direct method using sodium dithionite as reducing agent with radiochemical purity >95%. The product was stable up to six hours (at RT). Considerable adsorption problems were observed. Biological behavior was in accordance with the compounds' lipophilicity. The synthesis of TOC conjugates with HYNIC as BFC was done with 45%±5% (n=3) yield. Labelling of HYNIC-TOC with tricine as co-ligand was conducted with up to 90% yield. Studies of RC-160 labelling using

  14. Applichation of the sulphate ceric dosimetric in the high doses range

    International Nuclear Information System (INIS)

    Prieto Miranda, F.

    1991-01-01

    The ceric-cerous dosimetric system is one of the system more employed in the high dose dosimetry. The spectrophotometric procedure to measure the ceric-concentration is an usual analityc method to determine the absorbed dose. On the other hand, due at increase employ of the irradiation process control. In this paper is realized the ceric-cerous dosimetric calibration in the dose range of 0,6 - 5 kGy and the application in the irradiation process control to differents absorbed dose values

  15. Absolute and relative dose measurements with Gafchromic trade mark sign EBT film for high energy electron beams with different doses per pulse

    International Nuclear Information System (INIS)

    Fiandra, Christian; Ragona, Riccardo; Ricardi, Umberto; Anglesio, Silvia; Giglioli, Francesca Romana

    2008-01-01

    The authors have evaluated the accuracy, in absolute and relative dose measurements, of the Gafchromic trade mark sign EBT film in pulsed high-energy electron beams. Typically, the electron beams used in radiotherapy have a dose-per-pulse value of less than 0.1 mGy/pulse. However, very high dose-per-pulse electron beams are employed in certain linear accelerators dedicated to intraoperatory radiation therapy (IORT). In this study, the absorbed dose measurements with Gafchromic trade mark sign EBT in both low (less than 0.3 mGy per pulse) and high (30 and 70 mGy per pulse) dose-per-pulse electron beams were compared with ferrous sulfate chemical Fricke dosimetry (operated by the Italian Primary Standard Dosimetry Laboratory), a method independent of the dose per pulse. A summary of Gafchromic trade mark sign EBT in relative and absolute beam output determination is reported. This study demonstrates the independence of Gafchromic trade mark sign EBT absorption as a function of dose per pulse at different dose levels. A good agreement (within 3%) was found with Fricke dosimeters for plane-base IORT applicators. Comparison with a diode detector is presented for relative dose measurements, showing acceptable agreement both in the steep dose falloff zone and in the homogeneous dose region. This work also provides experimental values for recombination correction factor (K sat ) of a Roos (plane parallel) ionization chamber calculated on the basis of theoretical models for charge recombination.

  16. Preliminary research on relationship between the somatostatin level and diabetes mellitus

    International Nuclear Information System (INIS)

    Shi Hongzhen; Wang Zizheng; Du Tongxin; Liu Jiaqin; Wei Jin; Qi Shaokang

    1996-01-01

    To study the relationship between somatostatin (SS) and diabetes mellitus (DM), and also among SS, C-peptide (C-P), insulin (INS), and glucagon (Gluc). Fasting and postprandial 2h plasma SS, INS, C-P and Gluc in 17 patients of IDDM, 22 patients of NIDDM and 23 normal controls were detected simultaneously by RIA. Dynamic assessment of above parameters was performed at 0,30,60,120,180 min in 8 cases of NIDDM with oral glucose tolerance test (OGTT). Fasting and postprandial 2h SS and Gluc levels were significantly higher in DM than in normal controls. The ratios of SS/INS and Gluc/SS in IDDM were higher than those in NIDDM and normal controls, while no difference was found in NIDDM and normal controls. Fasting Gluc/SS was similar in three groups, but increased significantly in DM after oral glucose intake and postprandial state. OGTT found that the levels of SS both in patients of nIDDM and normal controls reached its maximum at 30 min with a smaller amplitude in peak value in patient group, while the levels of INS, C-P and Gluc attained its climax at 60 min, lagging behind the normal controls (30 min), with a sustained high levels at 180 min. There was a difference of SS-secreting phase between DM and normal controls. The ratios of SS/INS, Gluc/INS provided an important reference value for diagnosis of DM. A relative insufficiency of SS secretion and Gluc/SS imbalance under glucose-loading may play an important role in the etiology of DM

  17. High-speed radiation dose calculations for severe accidents using INDOS

    International Nuclear Information System (INIS)

    Davidson, G.R.; Godin-Jacqmin, L.J.; Raines, J.C.

    1992-01-01

    The computer code INDOS (in-plant dose) has been developed for the high-speed calculation of in-plant radiation dose rates and doses during and/or due to a severe accident at a nuclear power plant. This paper describes the current capabilities of the code and presents the results of calculations for several severe-accident scenarios. The INDOS code can be run either as a module of MAAP, a code widely used in the nuclear industry for simulating the response of a light water reactor system during severe accidents, or as a stand-alone code using output from an alternative companion code. INDOS calculates gamma dose rates and doses in major plant compartments caused by airborne and deposited fission products released during an accident. The fission product concentrations are determined by the companion code

  18. A comparison of high-dose and low-dose tranexamic acid antifibrinolytic protocols for primary coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Stephen M McHugh

    2016-01-01

    Full Text Available Background and Aims: Tranexamic acid (TA is used for prophylactic antifibrinolysis in coronary artery bypass surgeries to reduce bleeding. We evaluated the efficacy of two different doses of TA for prophylactic antifibrinolysis in patients undergoing primary coronary artery bypass grafting (CABG surgery in this retrospective cohort study at a tertiary care referral centre. Methods: One-hundred eighty-four patients who underwent primary CABG with cardiopulmonary bypass (CPB via sternotomy between January 2009 and June 2011 were evaluated. Pre-operative patient characteristics, intraoperative data, post-operative bleeding, transfusions, organ dysfunction and 30-day mortality were compared between high-dose TA (30 mg/kg loading dose followed by infusion of 15 mg/kg/h until the end of surgery along with 2 mg/kg priming dose in the bypass circuit and low-dose TA (15 mg/kg loading dose followed by infusion of 6 mg/kg/h until the end of surgery along with 1 mg/kg priming dose in the bypass circuit groups. Univariate comparative analysis of all categorical and continuous variables was performed between the two groups by appropriate statistical tests. Linear and logistic regression analyses were performed to control for the effect of confounding on the outcome variables. Results: Chest tube output, perioperative transfusion of blood products and incidence of re-exploration for bleeding did not differ significantly (P> 0.05 between groups. Post-operative complications and 30-day mortality were comparable between the groups. The presence of cardiogenic shock and increased pre-operative creatinine were found to be associated with increased chest tube output on the post-operative day 2 by multivariable linear regression model. Conclusions: Low-dose TA protocol is as effective as high-dose protocol for antifibrinolysis in patients undergoing primary CABG with CPB.

  19. The Role of the Neuropeptide Somatostatin on Methamphetamine and Glutamate-Induced Neurotoxicity in the Striatum of Mice

    Science.gov (United States)

    Afanador, Lauriaselle; Mexhitaj, Ina; Diaz, Carolyn; Ordonez, Dalila; Baker, Lisa; Angulo, Jesus A.

    2014-01-01

    A large body of evidence shows that methamphetamine (METH) causes sustained damage to the brain in animal models and human METH users. In chronic users there are indications of cognitive and motor deficits. Striatal neuropeptides are in a position to modulate the neurochemical effects of METH and consequently striatal neural damage. Somatostatin (SST) is an intrinsic striatal neuropeptide that has been shown to inhibit glutamate transmission; glutamate is integral to METH toxicity and contributes to nitric oxide (NO) synthesis. We hypothesize that SST will protect from METH by inhibition of NO synthesis and thus reducing oxidative stress. To this end, the SST analogue octreotide (OCT) was microinjected into the striatum prior to a systemic injection of METH (30 mg/kg). We then assessed 3-nitrotyrosine (3-NT), an indirect index of NO production, tyrosine hydroxylase (TH) protein levels (dopamine terminal marker) and Fluoro-Jade C positive cells (degenerating cells). The SST agonist OCT dose dependently attenuated the METH-induced accumulation of striatal 3-NT. Moreover, pretreatment with OCT effectively mitigated cell death but failed to protect dopamine terminals. Next we co-infused OCT and NMDA and measured 3-NT and Fluoro-Jade C staining. Treatment with OCT had no effect on these parameters. The data demonstrate that SST attenuates the METH-induced production of NO protecting the striatum from the METH-induced cell loss. However, SST failed to prevent the toxicity of the dopamine terminals suggesting that pre- and post-synaptic striatal damage occur via independent mechanisms. PMID:23524190

  20. Somatostatin receptor positron emission tomography/computed tomography (PET/CT) in the evaluation of opsoclonus-myoclonus ataxia syndrome

    International Nuclear Information System (INIS)

    Joshi, Prathamesh; Lele, Vikram

    2013-01-01

    Opsoclonus-myoclonus ataxia (OMA) syndrome is the most common paraneoplastic neurological syndrome of childhood, associated with occult neuroblastoma in 20%-50% of all cases. OMA is the initial presentation of neuroblastoma in 1%-3% of children. Conventional radiological imaging approaches include chest radiography and abdominal computed tomography (CT). Nuclear medicine techniques, in form of 123 I/ 131 I-metaiodobenzylguanidine (MIBG) scintigraphy have been incorporated in various diagnostic algorithms for evaluation of OMA. We describe use of somatostatin receptor PET/CT with 68 Gallium- DOTA-DPhe 1 , Tyr 3 -octreotate (DOTATATE) in diagnosis of neuroblastoma in two cases of OMA

  1. Somatostatin receptor positron emission tomography/computed tomography (PET/CT) in the evaluation of opsoclonus-myoclonus ataxia syndrome.

    Science.gov (United States)

    Joshi, Prathamesh; Lele, Vikram

    2013-04-01

    Opsoclonus-myoclonus ataxia (OMA) syndrome is the most common paraneoplastic neurological syndrome of childhood, associated with occult neuroblastoma in 20%-50% of all cases. OMA is the initial presentation of neuroblastoma in 1%-3% of children. Conventional radiological imaging approaches include chest radiography and abdominal computed tomography (CT). Nuclear medicine techniques, in form of (123)I/(131)I-metaiodobenzylguanidine (MIBG) scintigraphy have been incorporated in various diagnostic algorithms for evaluation of OMA. We describe use of somatostatin receptor PET/CT with (68)Gallium- DOTA-DPhe(1), Tyr(3)-octreotate (DOTATATE) in diagnosis of neuroblastoma in two cases of OMA.

  2. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis, E-mail: acapellizzon@hcancer.org.br [A.C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Departamento de Radioterapia

    2016-05-15

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. (author)

  3. Effect of High-Dose vs Standard-Dose Wintertime Vitamin D Supplementation on Viral Upper Respiratory Tract Infections in Young Healthy Children.

    Science.gov (United States)

    Aglipay, Mary; Birken, Catherine S; Parkin, Patricia C; Loeb, Mark B; Thorpe, Kevin; Chen, Yang; Laupacis, Andreas; Mamdani, Muhammad; Macarthur, Colin; Hoch, Jeffrey S; Mazzulli, Tony; Maguire, Jonathon L

    2017-07-18

    Epidemiological studies support a link between low 25-hydroxyvitamin D levels and a higher risk of viral upper respiratory tract infections. However, whether winter supplementation of vitamin D reduces the risk among children is unknown. To determine whether high-dose vs standard-dose vitamin D supplementation reduces the incidence of wintertime upper respiratory tract infections in young children. A randomized clinical trial was conducted during the winter months between September 13, 2011, and June 30, 2015, among children aged 1 through 5 years enrolled in TARGet Kids!, a multisite primary care practice-based research network in Toronto, Ontario, Canada. Three hundred forty-nine participants were randomized to receive 2000 IU/d of vitamin D oral supplementation (high-dose group) vs 354 participants who were randomized to receive 400 IU/d (standard-dose group) for a minimum of 4 months between September and May. The primary outcome was the number of laboratory-confirmed viral upper respiratory tract infections based on parent-collected nasal swabs over the winter months. Secondary outcomes included the number of influenza infections, noninfluenza infections, parent-reported upper respiratory tract illnesses, time to first upper respiratory tract infection, and serum 25-hydroxyvitamin D levels at study termination. Among 703 participants who were randomized (mean age, 2.7 years, 57.7% boys), 699 (99.4%) completed the trial. The mean number of laboratory-confirmed upper respiratory tract infections per child was 1.05 (95% CI, 0.91-1.19) for the high-dose group and 1.03 (95% CI, 0.90-1.16) for the standard-dose group, for a between-group difference of 0.02 (95% CI, -0.17 to 0.21) per child. There was no statistically significant difference in number of laboratory-confirmed infections between groups (incidence rate ratio [RR], 0.97; 95% CI, 0.80-1.16). There was also no significant difference in the median time to the first laboratory-confirmed infection: 3.95 months

  4. High dose rate brachytherapy for oral cancer.

    Science.gov (United States)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Furukawa, Souhei; Koizumi, Masahiko; Ogawa, Kazuhiko

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer.

  5. Tumour uptake of the radiolabelled somatostatin analogue [DOTA0,TYR3]octreotide is dependent on the peptide amount

    International Nuclear Information System (INIS)

    Jong, M. de; Breeman, W.A.P.; Bernard, B.F.; Gameren, A. van; Bruin, E. de; Bakker, W.H.; Van der Pluijm, M.E.; Krenning, E.P.; Visser, T.J.; Maecke, H.R.

    1999-01-01

    Radiolabelled tumour receptor-binding peptides can be used for in vivo scintigraphic imaging. Recently, the somatostatin analogue [Tyr 3 ]octreotide (d-Phe-c(Cys-Tyr-d-Trp-Lys-Thr-Cys)-Thr(ol)) was derivatized with the chelator DOTA (tetra-azacyclododecane-tetra-acetic acid), enabling stable radiolabelling with both the high-energy beta particle-emitter yttrium-90 and the Auger electron-emitter indium-111. The thus produced radiolabelled compounds are promising for peptide receptor radionuclide therapy. Our previous in vitro and in vivo (rat) experiments with these radiolabelled compounds showed favourable binding and biodistribution characteristics with high uptake and retention in the target organs. We also demonstrated receptor-specific, time- and temperature-dependent internalization of radiolabelled [DOTA 0 ,Tyr 3 ]octreotide in somatostatin receptor subtype 2 (sst 2 )-positive rat pancreatic tumour cell lines. In this study we have investigated the effects of differences in the amount of injected peptide on tissue distribution of 111 In-labelled [DOTA 0 ,Tyr 3 ]octreotide in normal, i.e. non-tumour-bearing, and CA20948 tumour-bearing rats. This was done in order to find the amount of peptide at which the highest uptake in target tissues is achieved, and thereby to increase the potential of radionuclide therapy while simultaneously ensuring the lowest possible radiotoxicity in normal organs. Uptake of radiolabelled [DOTA 0 ,Tyr 3 ]octreotide in sst 2 -positive organs showed different bell-shaped functions of the amount of injected peptide, being highest at 0.05 (adrenals), 0.05-0.1 (pituitary and stomach) and 0.25 (pancreas) μg. Uptake in the tumour was highest at 0.5 μg injected peptide. The highest uptake was found at peptide amounts that were lower than those reported for [ 111 In-DTPA 0 ]octreotide (d-Phe-c(Cys-Phe-d-Trp-Lys-Thr-Cys)-Thr(ol), DTPA = diethylene-triamine-penta-acetic acid), consistent with the higher receptor affinity of the first compound

  6. Low dose versus high dose anti-snake venom therapy in the treatment of haematotoxic snake bite in South India.

    Science.gov (United States)

    Joseph, Imanto M; Kuriakose, Cijoy K; Dev, Anand Vimal; Philip, George A

    2017-10-01

    Most of the studies on the appropriate dose of anti-snake venom (ASV) are from tertiary hospitals and the guidelines are unclear. Our observational study compared the outcomes of two prevalent treatment regimes for haematotoxic snake bite in a secondary care hospital in South India. The time to normalisation of whole blood clotting time, mortality and complications were not different between the groups. The average dose of ASV required in the low and high dose groups were 106 mL and 246 mL, respectively. Consequently, patients who received low dose ASV incurred approximately 50% less expense. Urticarial rashes were also significantly fewer in the low dose group.

  7. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  8. Brachytherapy for early oral tongue cancer. Low dose rate to high dose rate

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Inoue, Toshihiko; Furukawa, Souhei; Kakimoto, Naoya

    2003-01-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n=341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer. (author)

  9. Radiation shielding and dose rate distribution for the building of the high dose rate accelerator

    International Nuclear Information System (INIS)

    Matsuda, Koji; Takagaki, Torao; Nakase, Yoshiaki; Nakai, Yohta.

    1984-03-01

    A high dose rate electron accelerator was established at Osaka Laboratory for Radiation Chemistry, Takasaki Establishment, JAERI in the fiscal year of 1975. This report shows the fundamental concept for the radiation shielding of the accelerator building and the results of their calculations which were evaluated through the model experiments. After the construction of the building, the leak radiation was measured in order to evaluate the calculating method of radiation shielding. Dose rate distribution of X-rays was also measured in the whole area of the irradiation room as a data base. (author)

  10. Can we avoid high levels of dose escalation for high-risk prostate cancer in the setting of androgen deprivation?

    Science.gov (United States)

    Shakespeare, Thomas P; Wilcox, Shea W; Aherne, Noel J

    2016-01-01

    Both dose-escalated external beam radiotherapy (DE-EBRT) and androgen deprivation therapy (ADT) improve outcomes in patients with high-risk prostate cancer. However, there is little evidence specifically evaluating DE-EBRT for patients with high-risk prostate cancer receiving ADT, particularly for EBRT doses >74 Gy. We aimed to determine whether DE-EBRT >74 Gy improves outcomes for patients with high-risk prostate cancer receiving long-term ADT. Patients with high-risk prostate cancer were treated on an institutional protocol prescribing 3-6 months neoadjuvant ADT and DE-EBRT, followed by 2 years of adjuvant ADT. Between 2006 and 2012, EBRT doses were escalated from 74 Gy to 76 Gy and then to 78 Gy. We interrogated our electronic medical record to identify these patients and analyzed our results by comparing dose levels. In all, 479 patients were treated with a 68-month median follow-up. The 5-year biochemical disease-free survivals for the 74 Gy, 76 Gy, and 78 Gy groups were 87.8%, 86.9%, and 91.6%, respectively. The metastasis-free survivals were 95.5%, 94.5%, and 93.9%, respectively, and the prostate cancer-specific survivals were 100%, 94.4%, and 98.1%, respectively. Dose escalation had no impact on any outcome in either univariate or multivariate analysis. There was no benefit of DE-EBRT >74 Gy in our cohort of high-risk prostate patients treated with long-term ADT. As dose escalation has higher risks of radiotherapy-induced toxicity, it may be feasible to omit dose escalation beyond 74 Gy in this group of patients. Randomized studies evaluating dose escalation for high-risk patients receiving ADT should be considered.

  11. Response, survival, and long-term toxicity after therapy with the radiolabeled somatostatin analogue [90Y-DOTA]-TOC in metastasized neuroendocrine cancers.

    Science.gov (United States)

    Imhof, Anna; Brunner, Philippe; Marincek, Nicolas; Briel, Matthias; Schindler, Christian; Rasch, Helmut; Mäcke, Helmut R; Rochlitz, Christoph; Müller-Brand, Jan; Walter, Martin A

    2011-06-10

    To investigate response, survival, and safety profile of the somatostatin-based radiopeptide (90)yttrium-labeled tetraazacyclododecane-tetraacetic acid modified Tyr-octreotide ([(90)Y-DOTA]-TOC) in neuroendocrine cancers. In a clinical phase II single-center open-label trial, patients with neuroendocrine cancers were treated with repeated cycles of [(90)Y-DOTA]-TOC. Each cycle consisted of a single intravenous injection of 3.7GBq/m(2) body-surface [(90)Y-DOTA]-TOC. Additional cycles were withheld in case of tumor progression and/or permanent toxicity. Overall, 1,109 patients received 2,472 cycles of [(90)Y-DOTA]-TOC (median, two; range, one to 10 cycles per patient). Of the 1,109 patients, 378 (34.1%) experienced morphologic response; 172 (15.5%), biochemical response; and 329 (29.7%), clinical response. During a median follow-up of 23 months, 491 patients (44.3%) died. Longer survival was correlated with each: morphologic (hazard ratio [HR], 0.46; 95% CI, 0.38 to 0.56; median survival, 44.7 v 18.3 months; P TOC treatment in a large cohort. Response to [(90)Y-DOTA]-TOC is associated with longer survival. Somatostatin receptor imaging is predictive for both survival after [(90)Y-DOTA]-TOC treatment and occurrence of renal toxicity.

  12. Interaction of 2-Gy Equivalent Dose and Margin Status in Perioperative High-Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Martinez-Monge, Rafael; Cambeiro, Mauricio; Moreno, Marta; Gaztanaga, Miren; San Julian, Mikel; Alcalde, Juan; Jurado, Matias

    2011-01-01

    Purpose: To determine patient, tumor, and treatment factors predictive of local control (LC) in a series of patients treated with either perioperative high-dose-rate brachytherapy (PHDRB) alone (Group 1) or with PHDRB combined with external-beam radiotherapy (EBRT) (Group 2). Patient and Methods: Patients (n = 312) enrolled in several PHDRB prospective Phase I-II studies conducted at the Clinica Universidad de Navarra were analyzed. Treatment with PHDRB alone, mainly because of prior irradiation, was used in 126 patients to total doses of 32 Gy/8 b.i.d. or 40 Gy/10 b.i.d. treatments after R0 or R1 resections. Treatment with PHDRB plus EBRT was used in 186 patients to total doses of 16 Gy/4 b.i.d. or 24 Gy/6 b.i.d. treatments after R0 or R1 resections along with 45 Gy of EBRT with or without concomitant chemotherapy. Results: No dose-margin interaction was observed in Group 1 patients. In Group 2 patients there was a significant interaction between margin status and 2-Gy equivalent (Eq2Gy) dose (p = 0.002): (1) patients with negative margins had 9-year LC of 95.7% at Eq2Gy = 62.9Gy; (2) patients with close margins of >1 mm had 9-year LC of 92.4% at Eq2Gy = 72.2Gy, and (3) patients with positive/close <1-mm margins had 9-year LC of 68.0% at Eq2Gy = 72.2Gy. Conclusions: Two-gray equivalent doses ≥70 Gy may compensate the effect of close margins ≥1 mm but do not counterbalance the detrimental effect of unfavorable (positive/close <1 mm) resection margins. No dose-margin interaction is observed in patients treated at lower Eq2Gy doses ≤50 Gy with PHDRB alone.

  13. Efficacy and Tolerability of High-Dose Escitalopram in Posttraumatic Stress Disorder.

    Science.gov (United States)

    Qi, Wei; Gevonden, Martin; Shalev, Arieh

    2017-02-01

    Open-label trials suggest that escitalopram (up to 20 mg/d) is an effective treatment for some, but not all posttraumatic stress disorder (PTSD) patients. Higher doses of escitalopram effectively reduced major depression symptoms in patients who had not responded to regular doses. The current study examines the efficacy, tolerability, and adherence to high-dose escitalopram in PTSD. Forty-five PTSD patients received 12 weeks of gradually increasing doses of escitalopram reaching 40 mg daily at 4 weeks. Among those, 12 participants received regular doses of antidepressants at study onset including escitalopram (n = 7). The Clinician-Administered PTSD Scale (CAPS) evaluated PTSD symptoms severity before treatment, at 3 months (upon treatment termination), and at 6 months (maintenance effect). A 20% reduction in CAPS scores was deemed clinically significant. Adverse events and medication adherence were monitored at each clinical session. Linear mixed-models analysis showed a significant reduction of mean CAPS scores (11.5 ± 18.1 points) at 3 months and maintenance of gains by 6 months (F2,34.56 = 8.15, P = 0.001). Eleven participants (34.3%) showed clinically significant improvement at 3 months. Only 9 participants (20%) left the study. There were no serious adverse events and few mild ones with only 2 adverse events (diarrhea, 11.1%; drowsiness, 11.1%) reported by more than 10% of participants. High doses of escitalopram are tolerable and well adhered to in PTSD. Their beneficial effect at a group level is due to a particularly good response in a subset of patients.Variability in prior pharmacological treatment precludes a definite attribution of the results to high doses of escitalopram.

  14. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  15. Neutron dose to patients treated with high-energy medical accelerators

    International Nuclear Information System (INIS)

    McGinley, P.H.

    2001-01-01

    The neutron dose equivalent received by patients treated with high energy x-ray beams was measured in this research. A total of 13 different medical accelerators were evaluated in terms of the neutron dose equivalent in the patient plane and at the beam center. The neutron dose equivalent at the beam center was found to ranged from 0.02 to 9.4 mSv per Sv of x-ray dose and values from 0.029 to 2.58 mSv per Sv of x-ray were measured in the patient plane. It was concluded that the neutron levels meet the International Electrotechnical Commission standard for the patient plane. It was also concluded that when intensity modulated radiation treatment is conducted the neutron dose equivalent received by the patient will increase by a factor of 2 to 10. (author)

  16. Hepatic Cyst Infection During Use of the Somatostatin Analog Lanreotide in Autosomal Dominant Polycystic Kidney Disease: An Interim Analysis of the Randomized Open-Label Multicenter DIPAK-1 Study

    NARCIS (Netherlands)

    Lantinga, M.A. (Marten A.); D’Agnolo, H.M.A. (Hedwig M. A.); E. Casteleijn (Eric); de Fijter, J.W. (Johan W.); E. Meijer (Esther); A.L. Messchendorp (A. Lianne); D. Peters (Dorien); M. Salih (Mahdi); E.M. Spithoven (Edwin); D. Soonawala (Darius); F.W. Visser (Folkert); Wetzels, J.F.M. (Jack F. M.); R. Zietse (Bob); J.P.H. Drenth (Joost); R.T. Gansevoort (Ron); Drenth, J.P.H.; J.W. de Fijter (Johan); Gansevoort, R.T.; D.J.M. Peters (Dorien J.M.); J.F.M. Wetzels (Jack); Zietse, R.

    2017-01-01

    textabstractIntroduction and Aims: The DIPAK-1 Study investigates the reno- and hepatoprotective efficacy of the somatostatin analog lanreotide compared with standard care in patients with later stage autosomal dominant polycystic kidney disease (ADPKD). During this trial, we witnessed several

  17. Study of a new glass matrix by thermoluminescent technique for high-dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Pamela Z.; Carvalho, Gabriel S. Marchiori de; Cunha, Diego M. da; Dantas, Noelio O.; Silva, Anielle C.A.; Neves, Lucio P.; Perini, Ana P., E-mail: anapaula.perini@ufu.br [Universidade Federal de Uberlandia (UFU), MG (Brazil). Instituto de Fisica; Linda, V.E. Caldas [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Carrera, Betzabel N.S.; Watanabe, Shigueo [Universidade de Sao Paulo (IF/USP), Sao Paulo, SP (Brazil). Instituto de Fisica

    2016-07-01

    The thermoluminescence technique is widely used for both personal and for high-dose dosimetry. In this work, the thermoluminescence technique was utilized to study a new glass matrix, with nominal composition of 20Li{sub 2}CO{sub 3}.10Al{sub 2}O{sub 3}.30BaO.40B{sub 2}O{sub 3} (mol%), irradiated with different doses in a {sup 60}Co source. The glow curves and the dose-response curve were obtained for radiation doses of 10, 50, 100, 200 e 700 Gy. The results showed that this new glass matrix has potential use in high-dose dosimetry. (author)

  18. Erythemal and therapeutic response of psoriasis to PUVA using high-dose UVA

    International Nuclear Information System (INIS)

    Speight, E.L.; Farr, P.M.

    1994-01-01

    In PUVA treatment of psoriasis, clinical observation suggests that uninvolved skin is more susceptible to PUVA erythema than lesions of psoriasis. If this is the case, then the efficacy of PUVA treatment might be increased by using localized high-dose UVA restricted to lesional skin. We have therefore studied the erythemal and therapeutic response of psoriasis to PUVA using high-dose UVA and, for comparison, the erythemal response to UVB. This study demonstrates that psoriasis may clear rapidly, without burning, using high-dose UVA. Availability of a suitable irradiation apparatus would allow rapid and effective PUVA treatment to be used for localized, resistant disease. (author)

  19. Treatment of carcinoma of uterine cervix with high-dose-rate intracavitary irradiation using Ralstron

    International Nuclear Information System (INIS)

    Suh, C.O.; Kim, G.E.; Loh, J.J.K.

    1988-01-01

    From May 1979 through December 1981, a total of 530 patients with carcinoma of the uterine cervix were treated with radiation therapy with curative intent. Of the 530 patients, 365 were treated with a high-dose-rate remote-controlled afterloading system (RALS) using a cobalt source, and 165 patients received a low dose rate using a radium source. External pelvic irradiation with a total of 40-50 Gy to the whole pelvis followed by intracavitary radiation (ICR) with a total dose of 30-39 Gy in ten to 13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rate with high-dose-rate ICR by stage was as follows: stage I:82.7% (N = 19) stage II:69.6% (N = 184), and stage III:52.2% (N = 156). The above results were comparable with those with conventional low-dose-rate ICR treatment, and late complications were far less. The application of high-dose-rate ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually none as compared with that of low-dose-rate ICR. Within a given period of time, more patients can be treated with high-dose-rate ICR because of the short treatment time. The authors therefore conclude that high-dose-rate ICR is suitable for a cancer center where a large number of patients are to be treated

  20. Ion exchange resins as high-dose radiation dosimeters

    International Nuclear Information System (INIS)

    Alian, A.; Dessouki, A.; El-Assay, N.B.

    1984-01-01

    This paper reports on the possibility of using various types of ion exchange resins as high-dose radiation dosimeters, by analysis of the decrease in exchange capacity with absorbed dose. The resins studied are Sojuzchim-export-Moscow Cation Exchanger KU-2 and Anion Exchanger AV-17 and Merck Cation Exchanger I, and Merck Anion Exchangers II and III. Over the dose range 1 to 100 kGy, the systems show linearity between log absorbed dose and decrease in resin ion exchange capacity. The slope of this response function differs for the different resins, depending on their ionic form and degree of cross-linking. The radiation sensitivity increases in the order KU-2; Exchanger I; AV-17; Exchanger II; Exchanger III. Merck resins with moisture content of 21% showed considerably higher radiation sensitivity than those with 2 to 3% moisture content. The mechanism of radiation-induced denaturing of the ion exchanger resins involves cleavage and decomposition of functional substituents, with crosslinking playing a stabilizing role, with water and its radiolytic products serving to inhibit radical recombination and interfering with the protection cage effect of crosslinking. (author)

  1. Can we avoid high levels of dose escalation for high-risk prostate cancer in the setting of androgen deprivation?

    Directory of Open Access Journals (Sweden)

    Shakespeare TP

    2016-05-01

    Full Text Available Thomas P Shakespeare,1,2 Shea W Wilcox,1 Noel J Aherne1,2 1Department of Radiation Oncology, North Coast Cancer Institute, 2Rural Clinical School, Faculty of Medicine, University of New South Wales, Coffs Harbour, NSW, Australia Aim: Both dose-escalated external beam radiotherapy (DE-EBRT and androgen deprivation therapy (ADT improve outcomes in patients with high-risk prostate cancer. However, there is little evidence specifically evaluating DE-EBRT for patients with high-risk prostate cancer receiving ADT, particularly for EBRT doses >74 Gy. We aimed to determine whether DE-EBRT >74 Gy improves outcomes for patients with high-risk prostate cancer receiving long-term ADT. Patients and methods: Patients with high-risk prostate cancer were treated on an institutional protocol prescribing 3–6 months neoadjuvant ADT and DE-EBRT, followed by 2 years of adjuvant ADT. Between 2006 and 2012, EBRT doses were escalated from 74 Gy to 76 Gy and then to 78 Gy. We interrogated our electronic medical record to identify these patients and analyzed our results by comparing dose levels. Results: In all, 479 patients were treated with a 68-month median follow-up. The 5-year biochemical disease-free survivals for the 74 Gy, 76 Gy, and 78 Gy groups were 87.8%, 86.9%, and 91.6%, respectively. The metastasis-free survivals were 95.5%, 94.5%, and 93.9%, respectively, and the prostate cancer-specific survivals were 100%, 94.4%, and 98.1%, respectively. Dose escalation had no impact on any outcome in either univariate or multivariate analysis. Conclusion: There was no benefit of DE-EBRT >74 Gy in our cohort of high-risk prostate patients treated with long-term ADT. As dose escalation has higher risks of radiotherapy-induced toxicity, it may be feasible to omit dose escalation beyond 74 Gy in this group of patients. Randomized studies evaluating dose escalation for high-risk patients receiving ADT should be considered. Keywords: radiotherapy, IMRT, dose

  2. High-Dose Versus Low-Dose Pitavastatin in Japanese Patients With Stable Coronary Artery Disease (REAL-CAD): A Randomized Superiority Trial.

    Science.gov (United States)

    Taguchi, Isao; Iimuro, Satoshi; Iwata, Hiroshi; Takashima, Hiroaki; Abe, Mitsuru; Amiya, Eisuke; Ogawa, Takanori; Ozaki, Yukio; Sakuma, Ichiro; Nakagawa, Yoshihisa; Hibi, Kiyoshi; Hiro, Takafumi; Fukumoto, Yoshihiro; Hokimoto, Seiji; Miyauchi, Katsumi; Yamazaki, Tsutomu; Ito, Hiroshi; Otsuji, Yutaka; Kimura, Kazuo; Takahashi, Jun; Hirayama, Atsushi; Yokoi, Hiroyoshi; Kitagawa, Kazuo; Urabe, Takao; Okada, Yasushi; Terayama, Yasuo; Toyoda, Kazunori; Nagao, Takehiko; Matsumoto, Masayasu; Ohashi, Yasuo; Kaneko, Tetsuji; Fujita, Retsu; Ohtsu, Hiroshi; Ogawa, Hisao; Daida, Hiroyuki; Shimokawa, Hiroaki; Saito, Yasushi; Kimura, Takeshi; Inoue, Teruo; Matsuzaki, Masunori; Nagai, Ryozo

    2018-05-08

    Current guidelines call for high-intensity statin therapy in patients with cardiovascular disease on the basis of several previous "more versus less statins" trials. However, no clear evidence for more versus less statins has been established in an Asian population. In this prospective, multicenter, randomized, open-label, blinded end point study, 13 054 Japanese patients with stable coronary artery disease who achieved low-density lipoprotein cholesterol (LDL-C) fashion to high-dose (pitavastatin 4 mg/d; n=6526) or low-dose (pitavastatin 1 mg/d; n=6528) statin therapy. The primary end point was a composite of cardiovascular death, nonfatal myocardial infarction, nonfatal ischemic stroke, or unstable angina requiring emergency hospitalization. The secondary composite end point was a composite of the primary end point and clinically indicated coronary revascularization excluding target-lesion revascularization at sites of prior percutaneous coronary intervention. The mean age of the study population was 68 years, and 83% were male. The mean LDL-C level before enrollment was 93 mg/dL with 91% of patients taking statins. The baseline LDL-C level after the run-in period on pitavastatin 1 mg/d was 87.7 and 88.1 mg/dL in the high-dose and low-dose groups, respectively. During the entire course of follow-up, LDL-C in the high-dose group was lower by 14.7 mg/dL than in the low-dose group ( P Japanese patients with stable coronary artery disease. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01042730. © 2018 The Authors.

  3. Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans

    Science.gov (United States)

    Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2012-01-01

    BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498

  4. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

    International Nuclear Information System (INIS)

    Fonseca, Gabriel Paiva; Yoriyaz, Hélio; Tedgren, Åsa Carlsson; Nilsson, Josef; Persson, Maria; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Dose calculation in high dose rate brachytherapy with 192 Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (D m,m ) and dose-to-water-in-medium (D w,m ). The relation between D m,m and D w,m for 192 Ir is the main goal of this study, in particular the dependence of D w,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: D m,m, D w,m (LCT), mean photon energy and photon fluence. D w,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between D m,m and D w,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between D w,m (SCT) and D w,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between D m,m and D w,m (SCT) mainly depend on tissue type, differences between D m,m and D w,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources. (paper)

  5. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer; Avaliacao da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Jetro Pereira de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina; Rosa, Luiz Antonio Ribeiro da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], e-mail: lrosa@ird.gov.br; Batista, Delano Valdivino Santos; Bardella, Lucia Helena [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil). Unit of Medical Physics; Carvalho, Arnaldo Rangel [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. of Thermoluminescent Dosimetry

    2009-03-15

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  6. High dose therapy with autologous stem cell support in malignant disorders

    International Nuclear Information System (INIS)

    Holte, H.; Kvaloey, S.O.; Engan, T.

    1996-01-01

    New biomedical knowledge may improve the diagnostic procedures and treatment provided by the Health Services, but at additional cost. In a social democratic health care system, the hospital budgets have no room for expensive, new procedures or treatments, unless these are funded through extra allocation from the central authorities. High dose therapy with autologous stem cell support in malignant disorders is an example of a new and promising, but rather expensive treatment, but its role in cancer therapy has yet to be established. The indications for testing high dose therapy with autologous stem cell support in various malignancies are discussed, with emphasis on the principles for deciding which categories of disease should have priority. The authors suggest some malignant disorder for which high dose therapy with stem cell support should be explored versus conventional treatment in randomized prospective trials. 8 refs., 1 tab

  7. High dose rate brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Koizumi, Masahiko; Ogawa, Kazuhiko; Furukawa, Souhei

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer. (author)

  8. Prevention of incipient diabetic nephropathy by high-dose thiamine and benfotiamine.

    Science.gov (United States)

    Babaei-Jadidi, Roya; Karachalias, Nikolaos; Ahmed, Naila; Battah, Sinan; Thornalley, Paul J

    2003-08-01

    Accumulation of triosephosphates arising from high cytosolic glucose concentrations in hyperglycemia is the trigger for biochemical dysfunction leading to the development of diabetic nephropathy-a common complication of diabetes associated with a high risk of cardiovascular disease and mortality. Here we report that stimulation of the reductive pentosephosphate pathway by high-dose therapy with thiamine and the thiamine monophosphate derivative benfotiamine countered the accumulation of triosephosphates in experimental diabetes and inhibited the development of incipient nephropathy. High-dose thiamine and benfotiamine therapy increased transketolase expression in renal glomeruli, increased the conversion of triosephosphates to ribose-5-phosphate, and strongly inhibited the development of microalbuminuria. This was associated with decreased activation of protein kinase C and decreased protein glycation and oxidative stress-three major pathways of biochemical dysfunction in hyperglycemia. Benfotiamine also inhibited diabetes-induced hyperfiltration. This was achieved without change in elevated plasma glucose concentration and glycated hemoglobin in the diabetic state. High-dose thiamine and benfotiamine therapy is a potential novel strategy for the prevention of clinical diabetic nephropathy.

  9. Dose characteristics of high-energy electrons, muons and photons

    International Nuclear Information System (INIS)

    Britvich, G.I.; Krupnyj, G.I.; Peleshko, V.N.; Rastsvetalov, Ya.N.

    1980-01-01

    Differential distribution of energy release at different depth of tissue-equivalent phantoms (plexiglas, polystyrene, polyethylene) at the energy of incident electrons, muons of 0.2-40 GeV and photons with the mean energy of 3.6 GeV are measured. The error of experimental results does not exceed 7%. On the basis of the data obtained dose characteristics of electrons, muons and photons for standard geometry are estimated. For all types of irradiation the maximum value of specific equivalent dose, nremxcm 2 /part. is presented. It is shown that published values of specific equivalent dose of electron radiation are higher in all the investigated energy range from 0.2 to 40 GeV, and for muon radiation a good agreement with the present experiment is observed. The highly precise results obtained which cover the wide dynamic range according to the energy of incident particles can serve as the basis for reconsidering the existing recommendations for dose characteristics of electron radiation [ru

  10. Comparison of fixed low dose versus high dose radioactive iodine for the treatment of hyperthyroidism: retrospective multifactorial analysis impacting the outcome of therapy

    International Nuclear Information System (INIS)

    Suresh Kumar, A.C.; Malhotra, G.; Basu, S.; Asopa, R.V.

    2010-01-01

    Full text: Radioactive iodine ( 131 I) as a fixed dose protocol is widely used for treatment of hyperthyroidism. However, there is no consensus on the best optimum dose for an individual patient. The objectives of this study were to observe the outcome of 131 I therapy in patients of primary hyperthyroidism in relation to fixed low dose versus high dose regimen, impact of antithyroid drugs and influence of thyroid gland size on therapy outcome. Materials and Methods: Study design: Retrospective analysis. Study group included 287 diagnosed patients of primary hyperthyroidism who had undergone 131 I therapy for the first time (68 M, 219 F; Mean age ± S.D.: 43.84 ± 12.53). All patients with low RAIU, thyrocardiac disease were excluded. Details of antithyroid (ATD) drug treatment were recorded. Analysis was done from 2002 till patients became euthyroid/hypothyroid or until January 2010. Each patient's response was evaluated initially at 6 weeks and thereafter every three months. Appropriate statistical tests were applied to compare treatment response between the groups. A P value<0.05 was considered significant. Results: Of 287 patients, 209 patients had been administered low dose (Mean ± S.D.: 4.68 ± 0.62 mCi) while 78 patients had received high dose (Mean ± S.D.: 9.15 ± 1.05 mCi) of radioiodine. 57.9% (121/ 209) patients in the low dose group responded as compared to 75.6% (59/78) in high dose group after a follow up of more than 36 months. Similarly, among patients with and without antithyroid drug treatment, grade II and above goiters the response rates were significantly higher for high dose group as compared to low dose group. Conclusion: We suggest that high dose radioiodine treatment with 8 to 10 mCi is effective in treating hyperthyroidism in patients with a better success rate than the low dose treatment with 3 to 5 mCi. This is also likely to be helpful in patients who have not received antithyroid drugs. It appears that clinically relevant

  11. High-dose preoperative chemoradiotherapy in esophageal cancer patients does not increase postoperative pulmonary complications: Correlation with dose-volume histogram parameters

    International Nuclear Information System (INIS)

    Hurmuzlu, Meysan; Ovrebo, Kjell; Wentzel-Larsen, Tore; Muren, Ludvig Paul; Viste, Asgaut; Smaaland, Rune

    2010-01-01

    Purpose: To investigate the association of high-dose preoperative chemoradiotherapy (CRT) and dose-volume histogram (DVH) parameters of lungs with incidence of postoperative pulmonary complications and to identify predictive clinical factors of pulmonary complications. Methods: Data of 65 patients were collected retrospectively. Thirty-five patients underwent transthoracic esophagectomy (TTE) alone and 30 received cisplatin and 5-fluorouracil, concomitant with radiotherapy, median dose 66 Gy, and followed by TTE. From the DVH for each lung alone and for both lungs together as one organ we generated total lung volume, mean radiotherapy dose, relative and absolute volumes receiving more than a threshold dose, and relative and absolute volumes receiving less than a threshold dose. Postoperative pulmonary complications were defined as pneumonia or respiratory failure. Results: Sixty percent of the patients in the TTE alone group had postoperative pulmonary complications versus 63% in the CRT + TTE group. Postoperative mortality was 8.6% and 16.7% in the respective patient groups (p = NS). None of the DVH parameters was associated with postoperative pulmonary complications. Squamous cell carcinoma was an adverse factor related to increased postoperative pulmonary complications. Conclusion: High-dose preoperative CRT was not associated with increased postoperative pulmonary complications in this cohort of esophageal cancer patients.

  12. Preliminary PET/CT Imaging with Somatostatin Analogs [68Ga]DOTAGA-TATE and [68Ga]DOTAGA-TOC.

    Science.gov (United States)

    Satpati, Drishty; Shinto, Ajit; Kamaleshwaran, K K; Sarma, Haladhar Dev; Dash, Ashutosh

    2017-12-01

    Somatostatin receptor positron emission tomography/X-ray computed tomography (SSTR-PET/CT) is a well-established technique for staging and detection of neuroendocrine tumors (NETs). Ga-68-labeled DOTA-conjugated octreotide analogs are the privileged radiotracers for diagnosis and therapeutic monitoring of NETs. Hence, we were interested in assessing the influence of promising, newer variant DOTAGA on the hydrophilicity, pharmacokinetics, and lesion pick-up of somatostatin analogs. Herein, the potential of ([ 68 Ga]DOTAGA, Tyr 3 , Thr 8 ) octreotide ([ 68 Ga]DOTAGA-TATE) and ([ 68 Ga]DOTAGA, Tyr 3 ) octreotide ([ 68 Ga]DOTAGA-TOC) as NET imaging agents has been investigated. Amenability of [ 68 Ga]DOTAGA-(TATE/TOC) to kit-type formulation has been demonstrated. Biodistribution studies were carried out in normal rats at 1 h post-injection (p.i.). [ 68 Ga]DOTAGA-(TATE/TOC) PET/CT scans were carried out in patients (70-170 MBq, 1 h p.i.) with histologically confirmed well-differentiated NETs. [ 68 Ga]DOTAGA-TATE exhibited hydrophilicity similar to [ 68 Ga]DOTA-TATE (log P = -3.51 vs -3.69) whereas [ 68 Ga]DOTAGA-TOC was more hydrophilic than [ 68 Ga]DOTA-TOC (log P = -3.27 vs -2.93). [ 68 Ga]DOTAGA-TATE and [ 68 Ga]DOTA-TATE showed almost identical blood and kidney uptake in normal rats whereas significantly fast clearance (p TOC also demonstrated rapid clearance from blood and kidneys (p TOC. The metastatic lesions in NET patients were well identified by [ 68 Ga]DOTAGA-TATE and [ 68 Ga]DOTAGA-TOC. The phenomenal analogy was observed between [ 68 Ga]DOTAGA-TATE and [ 68 Ga]DOTA-TATE as well as between [ 68 Ga]DOTAGA-TOC and [ 68 Ga]DOTA-TOC in biodistribution studies in rats. The good lesion detection ability of the two radiotracers indicates their potential as NET imaging radiotracers.

  13. Unicentric Castleman's Disease Revealed by 18F-FDG PET/CT and Somatostatin Receptor Scintigraphy With 99mTc-HYNIC-TOC.

    Science.gov (United States)

    Luo, Yaping; Wang, Ling; Pan, Qingqing; Ma, Yanru; Li, Fang

    2018-07-01

    A 51-year-old woman with a history of hypertension and abdominal pain was found with a retroperitoneal mass. The mass had intense enhancement in contrast-enhanced CT, and it showed a moderate degree of increased FDG uptake in PET/CT. The mass was also positive in somatostatin receptor scintigraphy with Tc-HYNIC-TOC, but it was negative in I-MIBG scan. The histopathological result after surgical resection of the mass confirmed the diagnosis of Castleman's disease, the hyaline vascular variant.

  14. High-dose metoclopramide + lorazepam versus low-dose metoclopramide + lorazepam + dehydrobenzperidol in the treatment of cisplatin-induced nausea and vomiting

    DEFF Research Database (Denmark)

    Herrstedt, Jørn; Hannibal, J; Hallas, Jesper

    1991-01-01

    In a randomized double-blind, cross-over trial of 34 patients receiving cisplatin-based chemotherapy (20-100 mg/m2), the antiemetic effect of high-dose metoclopramide (HDM) (10 mg/kg iv. loading dose + 7 hours continuous infusion) + lorazepam (L) (2.5 mg x 4 po) was compared with low......-dose metoclopramide (LDM) (70 mg) + L (2.5 mg x 2 po) + dehydrobenzperidol (5 mg x 2 im). Among the 29 patients who completed the cross-over, HDM significantly reduced the number of vomiting episodes (p = 0.002) and the degree of nausea (p = 0.004). Seventeen patients preferred the HDM and 4 the LDM regimen (p = 0.......01). Sedation was seen in all but 1 patient, and was graded as severe in 6 patients receiving the HDM and in 2 patients receiving the LDM regimen. No extrapyramidal adverse reactions were seen. We conclude that high-dose metoclopramide + lorazepam is a safe antiemetic regimen and significantly superior to low...

  15. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  16. Guideline for PET/CT imaging of neuroendocrine neoplasms withGa-DOTA-conjugated somatostatin receptor targeting peptides andF-DOPA

    DEFF Research Database (Denmark)

    Bozkurt, Murat Fani; Virgolini, Irene; Balogova, Sona

    2017-01-01

    PURPOSE & METHODS: Neuroendocrine neoplasms are a heterogenous group of tumours, for which nuclear medicine plays an important role in the diagnostic work-up as well as in the targeted therapeutic options. This guideline is aimed to assist nuclear medicine physicians in recommending, performing......, reporting and interpreting the results of somatostatin receptor (SSTR) PET/CT imaging using68Ga-DOTA-conjugated peptides, as well as18F-DOPA imaging for various neuroendocrine neoplasms. RESULTS & CONCLUSION: The previous procedural guideline by EANM regarding the use PET/CT tumour imaging with68Ga...

  17. Radiotherapy after high-dose chemotherapy and peripheral blood stem cell support in high-risk breast cancer

    International Nuclear Information System (INIS)

    Hoeller, Ulrike; Heide, Juergen; Kroeger, Nicolaus; Krueger, William; Jaenicke, Fritz; Alberti, Winfried

    2002-01-01

    Purpose: To assess the toxicity and efficacy of radiotherapy with respect to locoregional control after adjuvant high-dose chemotherapy for patients with breast cancer. At first, radiotherapy was withheld because of toxicity concerns, but it was introduced in 1995 because of reported high locoregional relapse rates. Methods and Materials: Between 1992 and 1998, 40 patients with Stage II-III high-risk breast cancer received adjuvant high-dose chemotherapy consisting of thiotepa, mitoxantrone, and cyclophosphamide and peripheral blood stem cell support after four cycles of induction chemotherapy. The chest wall or breast, as well as the supraclavicular nodes, were irradiated with electrons and photons to a median dose of 50.4 Gy in 20 patients. Six additional patients received only supraclavicular irradiation to a median dose of 50.4 Gy. Acute toxicity was scored clinically. Pulmonary function tests were performed in 14 irradiated patients before high-dose chemotherapy and 1.1-4.4 years (median 1.6) after irradiation. The median follow-up time of living patients was 33 vs. 67 months in irradiated (n=26) and nonirradiated (n=14) patients, respectively. Results: G2 and G3 hematologic toxicity occurred in 1 patient each. No clinical pneumonitis or clinical impairment of lung function was observed. After 1-2 years, the lung function tests showed only minor changes in 4 patients. The 3-year locoregional control rate was 92% in the irradiated patients vs. 58% in the nonirradiated patients (p=0.049, actuarial analysis). Conclusion: In this series, adjuvant radiotherapy after adjuvant chemotherapy for breast cancer appeared well tolerated, with improved local regional control and without significant side effects. Longer follow-up and more patient accrual, as well as Phase III trials, are necessary for confirmation

  18. Esophageal Toxicity From High-Dose, Single-Fraction Paraspinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Cox, Brett W.; Jackson, Andrew; Hunt, Margie; Bilsky, Mark; Yamada, Yoshiya

    2012-01-01

    Purpose: To report the esophageal toxicity from single-fraction paraspinal stereotactic radiosurgery (SRS) and identify dosimetric and clinical risk factors for toxicity. Methods and Materials: A total of 204 spinal metastases abutting the esophagus (182 patients) were treated with high-dose single-fraction SRS during 2003-2010. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria for Adverse Events, version 4.0. Dose-volume histograms were combined to generate a comprehensive atlas of complication incidence that identifies risk factors for toxicity. Correlation of dose-volume factors with esophageal toxicity was assessed using Fisher’s exact test and logistic regression. Clinical factors were correlated with toxicity. Results: The median dose to the planning treatment volume was 24 Gy. Median follow-up was 12 months (range, 3-81). There were 31 (15%) acute and 24 (12%) late esophageal toxicities. The rate of grade ≥3 acute or late toxicity was 6.8% (14 patients). Fisher’s exact test resulted in significant median splits for grade ≥3 toxicity at V12 = 3.78 cm 3 (relative risk [RR] 3.7, P=.05), V15 = 1.87 cm 3 (RR 13, P=.0013), V20 = 0.11 cm 3 (RR 6, P=0.01), and V22 = 0.0 cm 3 (RR 13, P=.0013). The median split for D2.5 cm 3 (14.02 Gy) was also a significant predictor of toxicity (RR 6; P=.01). A highly significant logistic regression model was generated on the basis of D2.5 cm 3 . One hundred percent (n = 7) of grade ≥4 toxicities were associated with radiation recall reactions after doxorubicin or gemcitabine chemotherapy or iatrogenic manipulation of the irradiated esophagus. Conclusions: High-dose, single-fraction paraspinal SRS has a low rate of grade ≥3 esophageal toxicity. Severe esophageal toxicity is minimized with careful attention to esophageal doses during treatment planning. Iatrogenic manipulation of the irradiated esophagus and systemic agents classically associated with radiation recall reactions are

  19. Immune reactivity after high-dose irradiation

    International Nuclear Information System (INIS)

    Gassmann, W.; Wottge, H.U.; von Kolzynski, M.; Mueller-Ruchholtz, W.

    1986-01-01

    Immune reactivity after total-body irradiation was investigated in rats using skin graft rejection as the indicator system. After sublethal irradiation with 10.5 Gy (approximately 50% lethality/6 weeks) the rejection of major histocompatibility complex allogeneic skin grafts was delayed significantly compared with nonirradiated control animals (28 versus 6.5 days). In contrast, skin grafts were rejected after 7.5 days in sublethally irradiated animals and 7 days in lethally irradiated animals if additional skin donor type alloantigens--namely, irradiated bone marrow cells--were given i.v. either simultaneously or with a delay of not more than 24 hr after the above conditioning regimen. These reactions were alloantigen-specific. They were observed in six different strain combinations with varying donors and recipients. Starting on day 2 after irradiation, i.v. injection of bone marrow gradually lost its effectivity and skin grafts were no longer rejected with uniform rapidity; skin donor marrow given on days 4 or 8 did not accelerate skin graft rejection at all. These data show that for approximately 1-2 days after high-dose total-body irradiation rats are still capable of starting a vigorous immune reaction against i.v.-injected alloantigens. The phenomenon of impaired rejection of skin grafted immediately after high-dose irradiation appears to result from the poor accessibility of skin graft alloantigens during the early postirradiation phase when vascularization of the grafted skin is insufficient

  20. High-dose vitamin C and cancer

    Directory of Open Access Journals (Sweden)

    Ahmet Unlu, M.D.

    2016-01-01

    Full Text Available Vitamin C (ascorbic acid, ascorbate is a basic compound that is of great importance with its role in various enzymatic reactions including the synthesis of collagen, as well as with its redox functions. Vitamin C has become the center of interest in cancer studies, in consequence of the facts that connective tissue changes and vitamin C deficiency were first alleged to be associated with cancer in the 1950s; and that high doses of vitamin C was asserted to be cytotoxic for cancer cells, later on. The results of the first study carried out in the 1970s were promising; but afterwards, the studies were ascertained to be faulty. Despite the positive results achieved from some laboratory and animal experiments, randomized clinical trials did not verify those findings, and no clear benefit of vitamin C for cancer treatment could be demonstrated. As for studies, where its use in combination with other cancer treatment regimens was assessed, conflicting results were obtained. Although intake of high doses of vitamin C is alleged to be harmless, based on that it is in the group of water soluble vitamins and is not stored in the body, there are many side effects and drug interactions reported in the literature. For now, it is better to abstain from this treatment, until the benefit of the treatment (if any is clearly demonstrated, considering the potential side effects and interactions.

  1. High-dose ascorbic acid decreases cholesterolemic factors of an atherogenic diet in guinea pigs.

    Science.gov (United States)

    Filis, Konstantinos; Anastassopoulou, Aikaterini; Sigala, Fragiska; Theodorou, Dimitrios; Manouras, Andreas; Leandros, Emanouel; Sigalas, Panagiotis; Hepp, Wolfgang; Bramis, John

    2007-03-01

    The study evaluates the effect of a high supplemental dose of ascorbic acid (AA) on plasma concentrations of total cholesterol (TC), triglycerides (TG), total lipids (TL), and lipoprotein fractions high-density, very-low-density-, and low-density lipoprotein (HDL, VLDL, LDL) in guinea pigs fed with atherogenic diet. Group I consisted of 5 normally fed guinea pigs plus a low dose of AA (1 mg/100 g/day), group II consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a low dose of AA (1 mg/100 g/day), and group III consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a high dose of AA (30 mg/100 g/day). Cholesterolemic factors concentrations were determined after nine weeks. Concentrations of TC, TG, TL, LDL, and VLDL were increased in group II compared to group I (p < 0.01 for all differences). Supplementation with a high dose of AA resulted in decreased concentrations of TC (p < 0.01), TG (p < 0.01), TL (p < 0.01), and LDL (p < 0.01) in group III compared to group II. Additionally, concentration of HDL was increased in group III compared to group II (p < 0.01). High-dose AA supplementation to an atherogenic diet decreases concentrations of TC, TG, TL, and LDL and increases concentration of HDL compared to low-dose AA.

  2. Split high-dose oral levothyroxine treatment as a successful therapy option in myxedema coma.

    Science.gov (United States)

    Charoensri, Suranut; Sriphrapradang, Chutintorn; Nimitphong, Hataikarn

    2017-10-01

    High-dose intravenous thyroxine (T4) is the preferable treatment for myxedema coma. We describe the clinical course of a 69-year-old man who presented with myxedema coma and received oral levothyroxine (LT4) therapy (1 mg) in a split dose. This suggests split high-dose oral LT4 as a therapeutic option in myxedema coma.

  3. Dose-Dependent Cortical Thinning After Partial Brain Irradiation in High-Grade Glioma

    Energy Technology Data Exchange (ETDEWEB)

    Karunamuni, Roshan [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Bartsch, Hauke; White, Nathan S. [Department of Radiology, University of California San Diego, La Jolla, California (United States); Moiseenko, Vitali; Carmona, Ruben; Marshall, Deborah C.; Seibert, Tyler M. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); McDonald, Carrie R. [Department of Psychiatry, University of California San Diego, La Jolla, California (United States); Farid, Nikdokht; Krishnan, Anithapriya; Kuperman, Joshua [Department of Radiology, University of California San Diego, La Jolla, California (United States); Mell, Loren [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Brewer, James B.; Dale, Anders M. [Department of Radiology, University of California San Diego, La Jolla, California (United States); Hattangadi-Gluth, Jona A., E-mail: jhattangadi@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States)

    2016-02-01

    Purpose: Radiation-induced cognitive deficits may be mediated by tissue damage to cortical regions. Volumetric changes in cortex can be reliably measured using high-resolution magnetic resonance imaging (MRI). We used these methods to study the association between radiation therapy (RT) dose and change in cortical thickness in high-grade glioma (HGG) patients. Methods and Materials: We performed a voxel-wise analysis of MRI from 15 HGG patients who underwent fractionated partial brain RT. Three-dimensional MRI was acquired pre- and 1 year post RT. Cortex was parceled with well-validated segmentation software. Surgical cavities were censored. Each cortical voxel was assigned a change in cortical thickness between time points, RT dose value, and neuroanatomic label by lobe. Effects of dose, neuroanatomic location, age, and chemotherapy on cortical thickness were tested using linear mixed effects (LME) modeling. Results: Cortical atrophy was seen after 1 year post RT with greater effects at higher doses. Estimates from LME modeling showed that cortical thickness decreased by −0.0033 mm (P<.001) for every 1-Gy increase in RT dose. Temporal and limbic cortex exhibited the largest changes in cortical thickness per Gy compared to that in other regions (P<.001). Age and chemotherapy were not significantly associated with change in cortical thickness. Conclusions: We found dose-dependent thinning of the cerebral cortex, with varying neuroanatomical regional sensitivity, 1 year after fractionated partial brain RT. The magnitude of thinning parallels 1-year atrophy rates seen in neurodegenerative diseases and may contribute to cognitive decline following high-dose RT.

  4. Second malignancies in high-dose areas of previous tumor radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Welte, Birgitta; Suhr, Peter; Bottke, Dirk; Bartkowiak, Detlef; Wiegel, Thomas [Dept. of Radiotherapy and Radiation Oncology, Univ. of Ulm (Germany); Doerr, Wolfgang [Dept. of Radiotherapy and Radiation Oncology, Radiobiology Lab., Univ. of Technology Dresden (Germany); Trott, Klaus Ruediger [UCL Cancer Centre, Univ. Coll. London (United Kingdom)

    2010-03-15

    Purpose: To characterize second tumors that developed in or near the high-dose areas of a previous radiotherapy, regarding their frequency, entities, latency, and dose dependence. Patients and Methods: 9,995/15,449 tumor patients of the Radiation Oncology Department in Ulm, Germany, treated between 1981 and 2003, survived at least 1 year after radiotherapy. By long-term follow-up and review of treatment documentation, 100 of them were identified who developed an independent second cancer in or near the irradiated first tumor site. Results: Major primary malignancies were breast cancer (27%), lymphoma (24%), and pelvic gynecologic tumors (17%). Main second tumors were carcinomas of the upper (18%) and lower (12%) gastrointestinal tract, head and neck tumors (10%), lymphoma (10%), breast cancer (9%), sarcoma (9%), and lung cancer (8%). Overall median second tumor latency was 7.4 years (1-42 years). For colorectal cancer it was 3.5 and for leukemia 4.3 years, but for sarcoma 11.7 and for breast cancer 17.1 years. The relatively frequent second tumors of the upper gastrointestinal tract were associated with median radiation doses of 24 Gy. By contrast, second colorectal cancer and sarcoma developed after median doses of 50 Gy. Conclusion: The 5- and 15-year probability to develop a histopathologically independent second tumor in or near the irradiated first tumor site, i.e., after intermediate or high radiation doses, was 0.5% and 2.2%, respectively. To identify potentially radiogenic second malignancies, a follow-up far beyond 5 years is mandatory. The incidence and potential dose-response relationship intermediate will be analyzed by a case-case and a case-control study of the Ulm data. (orig.)

  5. Fast, three-dimensional, MR Imaging for polymer gel dosimetric applications involving high dose and steep dose gradients

    International Nuclear Information System (INIS)

    Sandilos, Panagiotis; Baras, Panagiotis; Georgiou, Evangelos; Dardoufas, Konstantinos; Karaiskos, Pantelis; Papagiannis, Panagiotis; Paschalis, Theodoros; Tatsis, Elias; Torrens, Michael; Vlahos, Lampros

    2006-01-01

    Polymer gels constitute water equivalent integrating detectors, which, combined with magnetic resonance imaging (MRI), can provide accurate three dimensional (3D) dose distributions in contemporary radiotherapy applications where the small field dimensions and steep dose gradients induce limitations to conventional dosimeters. One of the main obstacles for adapting the method for routine use in the clinical setting is the cost effectiveness of the MRI readout method. Currently, optimized Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo imaging pulse sequences are commonly used which however result in long imaging times. This work evaluates the efficiency of 3D, dual-echo, k-space segmented turbo spin echo (TSE) scanning sequences for accurate dosimetry with sub-millimetre spatial resolution in strenuous radiation therapy applications. PABIG polymer gel dosimeters were irradiated with an 192 Ir High Dose Rate brachytherapy source, the 4 mm and 8 mm collimator helmets of a gamma knife unit and a custom made x-knife collimator of 1 cm diameter. Profile and dose distribution measurements using TSE are benchmarked against corresponding findings obtained by the commonly used, but time consuming, CPMG sequence as well as treatment planning calculations, Monte Carlo (MC) simulations and film measurements. The implementation of a high Turbo factor was found to provide comparable accuracy, allowing a 64-fold MRI scan acceleration compared to conventional multi-echo sequences. The availability of TSE sequences in typical MRI installations greatly facilitates the introduction of polymer gel dosimetry in the clinical environment as a practicable tool for the determination of full 3D dose distributions in contemporary radiotherapy applications

  6. Fast, three-dimensional, MR Imaging for polymer gel dosimetric applications involving high dose and steep dose gradients

    Energy Technology Data Exchange (ETDEWEB)

    Sandilos, Panagiotis [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Baras, Panagiotis [Philips Hellas Medical Systems, 44 Kifissias Ave., Maroussi 151 25, Athens (Greece); Georgiou, Evangelos [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece); Dardoufas, Konstantinos [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece): Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Karaiskos, Pantelis [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece): Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece)]. E-mail: p.karaiskos@hygeia.gr; Papagiannis, Panagiotis [Physics Department, Nuclear and Particle Physics Section, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Paschalis, Theodoros [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Tatsis, Elias [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Torrens, Michael [Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Vlahos, Lampros [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece)

    2006-12-20

    Polymer gels constitute water equivalent integrating detectors, which, combined with magnetic resonance imaging (MRI), can provide accurate three dimensional (3D) dose distributions in contemporary radiotherapy applications where the small field dimensions and steep dose gradients induce limitations to conventional dosimeters. One of the main obstacles for adapting the method for routine use in the clinical setting is the cost effectiveness of the MRI readout method. Currently, optimized Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo imaging pulse sequences are commonly used which however result in long imaging times. This work evaluates the efficiency of 3D, dual-echo, k-space segmented turbo spin echo (TSE) scanning sequences for accurate dosimetry with sub-millimetre spatial resolution in strenuous radiation therapy applications. PABIG polymer gel dosimeters were irradiated with an {sup 192}Ir High Dose Rate brachytherapy source, the 4 mm and 8 mm collimator helmets of a gamma knife unit and a custom made x-knife collimator of 1 cm diameter. Profile and dose distribution measurements using TSE are benchmarked against corresponding findings obtained by the commonly used, but time consuming, CPMG sequence as well as treatment planning calculations, Monte Carlo (MC) simulations and film measurements. The implementation of a high Turbo factor was found to provide comparable accuracy, allowing a 64-fold MRI scan acceleration compared to conventional multi-echo sequences. The availability of TSE sequences in typical MRI installations greatly facilitates the introduction of polymer gel dosimetry in the clinical environment as a practicable tool for the determination of full 3D dose distributions in contemporary radiotherapy applications.

  7. Can high-dose fotemustine reverse MGMT resistance in glioblastoma multiforme?

    Science.gov (United States)

    Gallo, Chiara; Buonerba, Carlo; Di Lorenzo, Giuseppe; Romeo, Valeria; De Placido, Sabino; Marinelli, Alfredo

    2010-11-01

    Glioblastoma multiforme (GBM), the highest grade malignant glioma, is associated with a grim prognosis-median overall survival is in the range 12-15 months, despite optimum treatment. Surgery to the maximum possible extent, external beam radiotherapy, and systemic temozolomide chemotherapy are current standard treatments for newly diagnosed GBM, with intracerebral delivery of carmustine wafers (Gliadel). Unfortunately, the effectiveness of chemotherapy can be hampered by the DNA repair enzyme O6-methylguanine methyltransferase (MGMT), which confers resistance both to temozolomide and nitrosoureas, for example fotemustine and carmustine. MGMT activity can be measured by PCR and immunohistochemistry, with the former being the current validated technique. High-dose chemotherapy can deplete MGMT levels in GBM cells and has proved feasible in various trials on temozolomide, in both newly diagnosed and recurrent GBM. We here report the unique case of a GBM patient, with high MGMT expression by immunohistochemistry, who underwent an experimental, high-dose fotemustine schedule after surgery and radiotherapy. Although treatment caused two episodes of grade 3-4 thrombocytopenia, a complete response and survival of more than three years were achieved, with a 30% increase in dose intensity compared with the standard fotemustine schedule.

  8. Morphological Imaging in the Localization of Neuroendocrine Gastroenteropancreatic Tumors Found by Somatostatin Receptor Scintigraphy

    International Nuclear Information System (INIS)

    Saga, T.; Doi, R.; Endo, K.; Shimatsu, A.; Koizumi, K.; Ichikawa, T.; Yamamoto, K.; Noguchi, S.; Ishibashi, M.; Machinami, R.; Nakamura, K.; Sakahara, H.

    2005-01-01

    Purpose: To evaluate the necessity of morphological images (MI) in reading somatostatin receptor scintigraphy (SRS) in patients with suspected neuroendocrine gastroenteropancreatic (GEP) tumors. Material and Methods: A Japanese multicenter clinical trial of SRS was conducted in 40 patients with suspected GEP tumors. Three experienced radiologists interpreted the images in three separate sessions in a blinded manner (1: SRS images alone, 2: MI alone, 3: SRS and MI analyzed simultaneously), and the reading results of each session were compared. In addition, the diagnostic abilities of SRS, MI and SRS alone and simultaneous SRS and MI readings were compared for patients where final diagnosis was obtained. Results: SRS detected more suspected lesions (positive or inconclusive uptake) than morphological images did (51 vs 27 lesions), but included many physiological uptakes detected as positive or inconclusive uptakes. Combined reading of SRS and morphological images helped to correctly recognize these physiological uptakes, and also helped in determining the anatomical localization of the abnormal uptakes. Combined reading of SRS and morphological images gave the highest diagnostic impact. Conclusion: The sensitivity of SRS with regard to GEP is high. However the specificity is very low. Morphologic imaging is necessary for the exclusion of physiological uptake and correct anatomic location of an abnormal tracer uptake. The combined reading of SRS and morphologic imaging studies gives the highest diagnostic impact

  9. Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Bhavana [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Patel, Firuza D., E-mail: firuzapatel@gmail.com [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Chakraborty, Santam; Sharma, Suresh C.; Kapoor, Rakesh [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Aprem, Abi Santhosh [Corporate R and D Division, HLL Lifecare Limited, Karamana, Trivandrum (India)

    2013-04-01

    Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of

  10. Prehospital high-dose sublingual nitroglycerin rarely causes hypotension.

    Science.gov (United States)

    Clemency, Brian M; Thompson, Jeffrey J; Tundo, Gina N; Lindstrom, Heather A

    2013-10-01

    High-dose intravenous nitroglycerin is a common in-hospital treatment for respiratory distress due to congestive heart failure (CHF) with hypertension. Intravenous (IV) nitroglycerin administration is impractical in the prehospital setting. In 2011, a new regional Emergency Medical Services (EMS) protocol was introduced allowing advanced providers to treat CHF with high-dose oral nitroglycerin. The protocol calls for patients to be treated with two sublingual tabs (0.8 mg) when systolic blood pressure (SBP) was >160 mm Hg, or three sublingual tabs (1.2 mg) when SBP was >200 mm Hg, every five minutes as needed. Hypothesis/Problem To assess the protocol's safety, the incidence of hypotension following prehospital administration of multiple simultaneous nitroglycerin (MSN) tabs by EMS providers was studied. This study was a retrospective cohort study of patients from a single commercial EMS agency over a 6-month period. Records from patients with at least one administration of MSN were reviewed. For each administration, the first documented vital signs pre- and post-administration were compared. Administrations were excluded if pre- or post-administration vital signs were missing. One hundred case-patients had at least one MSN administration by an advanced provider during the study period. Twenty-five case-patients were excluded due to incomplete vital signs. Seventy-five case-patients with 95 individual MSN administrations were included for analysis. There were 65 administrations of two tabs, 29 administrations of three tabs, and one administration of four tabs. The mean change in SBP following MSN was -14.7 mm Hg (SD = 30.7; range, +59 to -132). Three administrations had documented systolic hypotension in the post-administration vital signs (97/71, 78/50 and 66/47). All three patients were over 65 years old, were administered two tabs, had documented improved respiratory status, and had repeat SBP of at least 100. The incidence of hypotension following MSN

  11. Characterization of Thymol blue Radiochromic dosimeters for high dose applications

    Directory of Open Access Journals (Sweden)

    Feras M. Aldweri

    2018-03-01

    Full Text Available Thymol blue (TB solutions and Thymol blue Polyvinyl Alcohol (TB-PVA films have been introduced as Radiochromic dosimeter for high dose applications. The dosimeters were irradiated with gamma ray (60Co source from 5 to 30 kGy for film, and from 0.150 kGy to 4 kGy for solution. The optical density of unirradiated and irradiated TB solution as well as TB-PVA film dosimeters were studied in terms of absorbance at 434 nm using UV/VIS spectrophotometer. The effects of scan temperature, light pre-gamma irradiation, dose rate, relative humidity and stability of the absorbance of solutions and films after irradiation were investigated. We found the dose sensitivity of TB solution and TB-PVA film dosimeters increases significantly with increases of the absorbed dose as well as with the increases of TB dye concentrations. The useful dose range of developed TB solutions and TB-PVA films dosimeters is in the range 0.125–1 kGy and of 5–20 kGy, respectively. Keywords: Dose sensitivity, Radio-chromic dosimeter, Thymol blue, Absorbance, Concentrations

  12. High-dose anti-histamine use and risk factors in children with urticaria.

    Science.gov (United States)

    Uysal, Pınar; Avcil, Sibelnur; Erge, Duygu

    2016-12-01

    The drugs of choice in the treatment of urticaria in children are H1-antihistamines. The aim of the study was to evaluate children with urticaria and define risk factors for requirement of high-dose H1-antihistamines in children with urticaria. The medical data of children who were diagnosed as having urticaria admitted to our outpatient clinic between January 2014 and January 2016 were searched. The medical histories, concomitant atopic diseases, parental atopy histories, medications, treatment responses, blood eosinophil and basophil counts, and serum total IgE levels were recorded. In addition, the urticaria activity score for seven days, autoimmune antibody tests, and skin prick test results were evaluated in children with chronic urticaria. The numbers of the children with acute and chronic urticaria were 138 and 92, respectively. The age of the children with chronic urticaria was higher than that of those with acute urticaria (p0.05). There was a negative correlation between blood eosinophil count and the UAS7 score in children with chronic urticaria (r=-0.276, p=0.011). Chronic urticaria and requirement of high dose H1-antihistamines were significant in children aged ≥10 years (p<0.001, p=0.015). High UAS7 score (OR: 1.09; CI 95%: [1.03-1.15]) and basopenia (OR: 6.77; CI 95%: [2.01-22.75]) were associated with the requirement of high-dose H1-AH in children with chronic urticaria. The requirement of high-dose H1-antihistamines was higher with children's increasing age. Disease severity and basopenia were risk factors for the requirement of high-dose H1-antihistamines.

  13. Surface applicators for high dose rate brachytherapy in AIDS-related kaposi's sarcoma

    International Nuclear Information System (INIS)

    Evans, Michael D.C.; Yassa, Mariam; Podgorsak, Ervin B.; Roman, Ted N.; Schreiner, L. John; Souhami, Luis

    1997-01-01

    Purpose: The development of commercially available surface applicators using high dose rate remote afterloading devices has enabled radiotherapy centers to treat selected superficial lesions using a remote afterloading brachytherapy unit. The dosimetric parameters of these applicators, the clinical implementation of this technique, and a review of the initial patient treatment regimes are presented. Methods and Materials: A set of six fixed-diameter (1, 2, and 3 cm), tungsten/steel surface applicators is available for use with a single stepping-source (Ir-192, 370 GBq) high dose rate afterloader. The source can be positioned either in a parallel or perpendicular orientation to the treatment plane at the center of a conical aperture that sits at an SSD of approximately 15 mm and is used with a 1-mm thick removable plastic cap. The surface dose rates, percent depth dose, and off-axis ratios were measured. A custom-built, ceiling-mounted immobilization device secures the applicator on the surface of the patient's lesion during treatment. Results: Between November 1994, and September 1996, 16 AIDS-related Kaposi's sarcoma patients having a total of 120 lesions have been treated with palliative intent. Treatment sites were distributed between the head and neck, extremity, and torso. Doses ranged from 8 to 20 Gy, with a median dose of 10 Gy delivered in a single fraction. Treatments were well tolerated with minimal skin reaction, except for patients with lesions treated to 20 Gy who developed moderate/severe desquamation. Conclusion: Radiotherapy centers equipped with a high dose rate remote afterloading unit may treat small selected surface lesions with commercially available surface applicators. These surface applicators must be used with a protective cap to eliminate electron contamination. The optimal surface dose appears to be either 10 or 15 Gy depending upon the height of the lesion

  14. Effects of moderate-dose versus high-dose trimethoprim on serum creatinine and creatinine clearance and adverse reactions.

    OpenAIRE

    Naderer, O; Nafziger, A N; Bertino, J S

    1997-01-01

    The effects of a 10-day course of moderate-dose (10 mg/kg/day) or high-dose (20 mg/kg/day) trimethoprim therapy on serum creatinine, measured creatinine clearance, urinary creatinine excretion, and serum folate were studied in 20 healthy volunteers. Serum creatinine concentrations increased significantly during trimethoprim therapy, began to decrease near day 10, and returned to baseline during the washout phase at both dosage levels. At the same time, measured creatinine clearance and urine ...

  15. Influence of high doses of manganese, copper, zinc and boron on some legumes

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, G

    1973-01-01

    Macroscopic and microscopic examinations showed the following symptoms of an excess in trace elements: (1) High doses of manganese (50-150 ppm) cause dark patches (chloroplast accumulation) in young leaves, and necrosis of the leaf margin (MnO/sub 2/ accumulation) in older leaves. The roots become brown and die off. Roots newly formed in compensation are strikingly light-colored. (2) High doses of copper (5-40 ppm) cause iron deficiency chlorosis. A large number of side roots develop in quick succession as a result of damage to the root apex, so that a thick tangle of roots is formed. (3) High doses of zinc (50-150 ppm) bring about dark green, very brittle young leaves with very high ZnO content. The older leaves become red and then yellow. The roots remain stunted because of inhibited growth in length. (4) High doses of boron (30-90 ppm) cause a leaf necrosis which proceeds in the sequence tip, margin, lamina. The roots are not affected in any characteristic way. They become brown and die off.

  16. Radiation dose in the high background radiation area in Kerala, India.

    Science.gov (United States)

    Christa, E P; Jojo, P J; Vaidyan, V K; Anilkumar, S; Eappen, K P

    2012-03-01

    A systematic radiological survey has been carried out in the region of high-background radiation area in Kollam district of Kerala to define the natural gamma-radiation levels. One hundred and forty seven soil samples from high-background radiation areas and five samples from normal background region were collected as per standard sampling procedures and were analysed for (238)U, (232)Th and (40)K by gamma-ray spectroscopy. External gamma dose rates at all sampling locations were also measured using a survey meter. The activities of (238)U, (232)Th and (40)K was found to vary from 17 to 3081 Bq kg(-1), 54 to 11976 Bq kg(-1) and BDL (67.4 Bq kg(-1)) to 216 Bq kg(-1), respectively, in the study area. Such heterogeneous distribution of radionuclides in the region may be attributed to the deposition phenomenon of beach sand soil in the region. Radium equivalent activities were found high in several locations. External gamma dose rates estimated from the levels of radionuclides in soil had a range from 49 to 9244 nGy h(-1). The result of gamma dose rate measured at the sampling sites using survey meter showed an excellent correlation with dose rates computed from the natural radionuclides estimated from the soil samples.

  17. High-precision radiosurgical dose delivery by interlaced microbeam arrays of high-flux low-energy synchrotron X-rays.

    Directory of Open Access Journals (Sweden)

    Raphaël Serduc

    Full Text Available Microbeam Radiation Therapy (MRT is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very high radiation doses (hundreds of Gy. Based on this well described normal tissue sparing effect of microplanar beams, we developed a new irradiation geometry which allows the delivery of a high uniform dose deposition at a given brain target whereas surrounding normal tissues are irradiated by well tolerated parallel microbeams only. Normal rat brains were exposed to 4 focally interlaced arrays of 10 microplanar beams (52 microm wide, spaced 200 microm on-center, 50 to 350 keV in energy range, targeted from 4 different ports, with a peak entrance dose of 200Gy each, to deliver an homogenous dose to a target volume of 7 mm(3 in the caudate nucleus. Magnetic resonance imaging follow-up of rats showed a highly localized increase in blood vessel permeability, starting 1 week after irradiation. Contrast agent diffusion was confined to the target volume and was still observed 1 month after irradiation, along with histopathological changes, including damaged blood vessels. No changes in vessel permeability were detected in the normal brain tissue surrounding the target. The interlacing radiation-induced reduction of spontaneous seizures of epileptic rats illustrated the potential pre-clinical applications of this new irradiation geometry. Finally, Monte Carlo simulations performed on a human-sized head phantom suggested that synchrotron photons can be used for human radiosurgical applications. Our data show that interlaced microbeam irradiation allows a high homogeneous dose deposition in a brain target and leads to a confined tissue necrosis while sparing

  18. Myocardial protection induced by fentanyl in pigs exposed to high-dose adrenaline.

    Science.gov (United States)

    da Luz, Vinicius Fernando; Otsuki, Denise Aya; Gonzalez, Maria Margarita Castro; Negri, Elnara Marcia; Caldini, Elia Garcia; Damaceno-Rodrigues, Nilsa Regina; Malbouisson, Luiz Marcelo Sá; Viana, Bruno Gonçalves; Vane, Matheus Fachini; Carmona, Maria Jose Carvalho

    2015-10-01

    The use of high doses of adrenaline is common in critical patients, especially during cardiac arrest. During these situations, myocardial dysfunction can be a result of multiple factors, including adrenaline use. In addition, opioids have been shown to have anti-arrhythmic and anti-ischemic mechanisms that may confer cardiac protection. This study aimed to evaluate the effects of fentanyl on myocardial function in pigs exposed to high-dose adrenaline. After institutional ethics committee approval, 26 pigs were randomly allocated to receive either 20 μg/kg fentanyl (n = 10; fentanyl group) administered 5 min before five doses of adrenaline (20 μg/kg), equivalent-volume saline (n = 10; saline group) using the same adrenaline dosing protocol, or neither fentanyl nor adrenaline (n = 6; sham group). The fentanyl group showed lower levels of troponin at the end of the sixth hour compared with the saline group (1.91 ± 1.47 vs 5.44 ± 5.35 ng/mL, P = 0.019). Transmission electron microscopy and immunohistochemistry also showed less myocardial injury in the fentanyl group. The conclusion was reached that fentanyl attenuates myocardial injury caused by high-dose adrenaline without blunting the hemodynamic effect of adrenaline. © 2015 Wiley Publishing Asia Pty Ltd.

  19. Image-Guided Stereotactic Radiosurgery Using a Specially Designed High-Dose-Rate Linac

    International Nuclear Information System (INIS)

    Bayouth, John E.; Kaiser, Heather S.; Smith, Mark C.; Pennington, Edward C.; Anderson, Kathleen M. C.; Ryken, Timothy C.; Buatti, John M.

    2007-01-01

    Stereotactic radiosurgery and image-guided radiotherapy (IGRT) place enhanced demands on treatment delivery machines. In this study, we describe a high-dose-rate output accelerator as a part of our stereotactic IGRT delivery system. The linac is a Siemens Oncor without a flattening filter, and enables dose rates to reach 1000 monitor units (MUs) per minute. Even at this high-dose-rate, the linac dosimetry system remains robust; constancy, linearity, and beam energy remain within 1% for 3 to 1000 MU. Dose profiles for larger field sizes are not flat, but they are radially symmetric and, as such, able to be modeled by a treatment planning system. Target localization is performed via optical guidance utilizing a 3-dimensional (3D) ultrasound probe coupled to an array of 4 infrared light-emitting diodes. These diodes are identified by a fixed infrared camera system that determines diode position and, by extension, all objects imaged in the room coordinate system. This system provides sub-millimeter localization accuracy for cranial applications and better than 1.5 mm for extracranial applications. Because stereotactic IGRT can require significantly longer times for treatment delivery, the advantages of the high-dose-rate design and its direct impact on IGRT are discussed

  20. High dose rate brachytherapy in treatment of high grade astrocytomas

    International Nuclear Information System (INIS)

    Garcia-Alejo, R.; Delgado, J.M.; Cerro, E. del; Torres, J.J.; Martinez, R.

    1996-01-01

    From May 1994 to June 1995, 18 patients with high grade astrocytomas were entered prospectively on a selective protocol combining surgery, external beam radiotherapy, stereotactic interstitial implantation with HDR Iridium 192 and chemotherapy. Only those patients with tumor size 100cc or less average dimension, high grade astrocytoma, Karnofsky 70 or greater, unilateral, circumscribed, unifocal, tumor stable or responding to external radiation and supratentorial were included in the study. Ages ranged from 16 to 69 years. There were 13 males and 5 females. Surgery consisted of biopsy only in 3 patients, subtotal resection in 11, and gross total resection in 4 patients. Focal external beam radiation portals included the contrast enhancing mass on CT scan plus a 3 cm margin. The protocol called for minimum tumor dose of 60 Gy to be given in 2 Gy daily fractions. An interstitial brachytherapy boost was to be performed two weeks after the conclusion of external beam radiation. The dose was 30 Gy in 4 fractions. The authors analyze on basis on their personal experience, the possibilities and the limits offered by this therapeutic procedure in neuro-oncology. Using stereotactic techniques, interstitial brachytherapy of brain tumors was technically possible with negligible acute morbidity and mortality, and appeared to be effective and may provide for an increase in tumor control in selected cases

  1. High-dose versus low-dose local anaesthetic for transversus abdominis plane block post-Caesarean delivery analgesia: a meta-analysis.

    Science.gov (United States)

    Ng, S C; Habib, A S; Sodha, S; Carvalho, B; Sultan, P

    2018-02-01

    The optimal local-anaesthetic (LA) dose for transversus-abdominis-plane (TAP) block is unclear. In this meta-analysis, we aimed to determine whether TAP blocks for Caesarean delivery (CD) with low-dose (LD) LA demonstrated non-inferiority in terms of analgesic efficacy, compared with high-dose (HD) LA. A literature search was performed for randomised controlled trials examining the analgesic efficacy of TAP blocks vs control after CD. The different dosing used in these studies was classified as HD or LD (bupivacaine equivalents >50 or ≤50 mg per block side, respectively). The pooled results of each dose group vs control were indirectly compared using the Q test. The primary outcome was 24 h opioid consumption. Secondary outcomes included 6 and 24 h postoperative pain scores, time to first analgesia, 6 h opioid consumption, opioid-related side-effects, and maternal satisfaction. Fourteen studies consisting of 770 women (389 TAP and 381 control) were included. Compared with controls, the 24 h opioid consumption (milligram morphine equivalents) was lower in HD [mean difference (MD) 95% confidence interval (CI) -22.41 (-38.56, -6.26); P=0.007; I 2 =93%] and LD [MD 95% CI -16.29 (-29.74, -2.84); P=0.02; I 2 =98%] TAP groups. However, no differences were demonstrated between the HD and LD groups (P=0.57). There were also no differences between the HD and LD groups for the 6 h opioid consumption, time to first analgesia, 6 and 24 h pain scores, postoperative nausea and vomiting, pruritus, and maternal satisfaction. Low-dose TAP blocks for Caesarean delivery provide analgesia and opioid-sparing effects comparable with the high-dose blocks. This suggests that lower doses can be used to reduce local anaesthetic toxicity risk without compromising the analgesic efficacy. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  2. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  3. [High-dosed gestagen therapy of the metastatic mammary carcinoma (author's transl)].

    Science.gov (United States)

    Firusian, N; Becher, R

    1981-12-01

    Thirty patients with histologically proven metastatic mammary carcinoma were treated, after exhaustion of hormonal and cytostatic therapeutic means, with high-dosed medroxyprogesterone acetate (MPA) during a ten-day induction phase with 1000 mg MPAi.m. per day and then with 600 mg oral MPA per day. In eleven patients a complete or partial remission was achieved. The median period of remission comprised ten months. A positive relationship was found between the response to high-dosed MPA therapy and the length of free intervals. Side effects were tolerable.

  4. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  5. High gamma dose response of the electrical properties of polyethylene terephthalate thin films

    International Nuclear Information System (INIS)

    Radwan, R.M.

    2007-01-01

    Electrical properties of polyethylene terephthalate (PET), irradiated with gamma rays, have been investigated. The PET films were irradiated with high gamma dose levels in the range from 100 to 2000 kGy. The changes in the DC (σ DC ) and the ac (σ ac ) conductivities, with the dose, have been performed. The effect of gamma irradiation on the dielectric constant (ε') and loss (ε'') has been determined. Also, the dose dependence of the frequency exponent index (S), the resonance frequency (Fc) and the hopping frequency (ω P ) have been obtained. The obtained results show that increasing gamma dose leads to slight increase in σ DC , σ ac and ε', while no change was observed in ε'' value. Meanwhile, S, Fc and ω P are inversely proportional to the dose. Accordingly, the study suggests the possibility of using PET films in electronic components (capacitors, resistors, etc.), especially that operate at high gamma dose environments for the frequency independent applications

  6. A high dose dosimeter based polyvinyl chloride dyed with malachite green

    International Nuclear Information System (INIS)

    Kattan, M.; Daher, Y.; Alkassiri, H.

    2007-01-01

    Polyvinyl chloride film (PVC) dyed with malachite green has been studied for high dose radiation dosimetry using visible spectrophotometry. A linear relationship between the relative absorbance and the absorbed dose at the wavelength 628 nm in the range of 0-125 kGy was found. The effect of dose rate, irradiation temperature, film thickness and dye intensity were found not to influence the response. The effects of shelf-life and the post-irradiation storage in darkness and indirect daylight conditions on dosimetry performance were discussed. (author)

  7. Neutron dose measurements with the GSI ball at high energy accelerators

    International Nuclear Information System (INIS)

    Fehrenbacher, G.; Gutermuth, F.; Radon, T.; Kozlova, E.

    2005-01-01

    Full text: At high energy particle accelerators the production of neutron radiation dominates radiation protection. For the radiation survey at accelerators there is a need for reliable detection systems (passive radiation monitors), which can measure the dose for a wide range of neutron energies independently on the beam pulse structure of the produced radiation. In this work a passive neutron dosemeter for the measurement of the ambient dose equivalent is presented. The dosemeter is suitable for measurements of the emerging neutron radiation at accelerators for the whole energy range up to about 10 GeV. The dosemeter consists of a polyethylene sphere, TL elements (pairs of TLD600/700) and an additional lead layer (PE/Pb) in neutron fields at high energy accelerators is investigated in this work. Results of dose measurements which were performed in realistic neutron fields at the high energy accelerator SPS at CERN (CERF facility) and in Cave A at the heavy ion synchrotron SIS at GSI are presented. The results of these measurements are compared with the expected dose values from the neutron spectra determined for the measurement positions at CERF and in Cave A (FLUKA) and with the dosemeter response derived by the calculated response functions (FLUKA) folded with the neutron spectra. The comparisons show that the additional lead layer in the PE/Pb-sphere improves significantly the response of the dosemeter. The response of the PE/Pb-sphere is 40 to 50 % higher at CERF and Cave A in comparison to the bare PE-sphere. At CERF the dose values of the PE/Pb-sphere is about 25 % lower than the expected dose value, whilst for Cave A, a rather good agreement was found (2 % deviation). (author)

  8. High-dose simultaneously integrated breast boost using intensity-modulated radiotherapy and inverse optimization

    International Nuclear Information System (INIS)

    Hurkmans, Coen W.; Meijer, Gert J.; Vliet-Vroegindeweij, Corine van; Sangen, Maurice J. van der; Cassee, Jorien

    2006-01-01

    Purpose: Recently a Phase III randomized trial has started comparing a boost of 16 Gy as part of whole-breast irradiation to a high boost of 26 Gy in young women. Our main aim was to develop an efficient simultaneously integrated boost (SIB) technique for the high-dose arm of the trial. Methods and Materials: Treatment planning was performed for 5 left-sided and 5 right-sided tumors. A tangential field intensity-modulated radiotherapy technique added to a sequentially planned 3-field boost (SEQ) was compared with a simultaneously planned technique (SIB) using inverse optimization. Normalized total dose (NTD)-corrected dose volume histogram parameters were calculated and compared. Results: The intended NTD was produced by 31 fractions of 1.66 Gy to the whole breast and 2.38 Gy to the boost volume. The average volume of the PTV-breast and PTV-boost receiving more than 95% of the prescribed dose was 97% or more for both techniques. Also, the mean lung dose and mean heart dose did not differ much between the techniques, with on average 3.5 Gy and 2.6 Gy for the SEQ and 3.8 Gy and 2.6 Gy for the SIB, respectively. However, the SIB resulted in a significantly more conformal irradiation of the PTV-boost. The volume of the PTV-breast, excluding the PTV-boost, receiving a dose higher than 95% of the boost dose could be reduced considerably using the SIB as compared with the SEQ from 129 cc (range, 48-262 cc) to 58 cc (range, 30-102 cc). Conclusions: A high-dose simultaneously integrated breast boost technique has been developed. The unwanted excessive dose to the breast was significantly reduced

  9. High dose rate (HDR) and low dose rate (LDR) interstitial irradiation (IRT) of the rat spinal cord

    International Nuclear Information System (INIS)

    Pop, Lucas A.M.; Plas, Mirjam van der; Skwarchuk, Mark W.; Hanssen, Alex E.J.; Kogel, Albert J. van der

    1997-01-01

    Purpose: To describe a newly developed technique to study radiation tolerance of rat spinal cord to continuous interstitial irradiation (IRT) at different dose rates. Material and methods: Two parallel catheters are inserted just laterally on each side of the vertebral bodies from the level of Th 10 to L 4 . These catheters are afterloaded with two 192 Ir wires of 4 cm length each (activity 1-2.3 mCi/cm) for the low dose rate (LDR) IRT or connected to the HDR micro-Selectron for the high dose rate (HDR) IRT. Spinal cord target volume is located at the level of Th 12 -L 2 . Due to the rapid dose fall-off around the implanted sources, a dose inhomogeneity across the spinal cord thickness is obtained in the dorso-ventral direction. Using the 100% reference dose (rate) at the ventral side of the spinal cord to prescribe the dose, experiments have been carried out to obtain complete dose response curves at average dose rates of 0.49, 0.96 and 120 Gy/h. Paralysis of the hind-legs after 5-6 months and histopathological examination of the spinal cord of each irradiated rat are used as experimental endpoints. Results: The histopathological damage seen after irradiation is clearly reflected the inhomogeneous dose distribution around the implanted catheters, with the damage predominantly located in the dorsal tract of the cord or dorsal roots. With each reduction in average dose rate, spinal cord radiation tolerance is significantly increased. When the dose is prescribed at the 100% reference dose rate, the ED 50 (induction of paresis in 50% of the animals) for the HDR-IRT is 17.3 Gy. If the average dose rate is reduced from 120 Gy/h to 0.96 or 0.49 Gy/h, a 2.9- or 4.7-fold increase in the ED 50 values to 50.3 Gy and 80.9 Gy is observed; for the dose prescribed at the 150% reference dose rate (dorsal side of cord) ED 50 values are 26.0, 75.5 and 121.4 Gy, respectively. Using different types of analysis and in dependence of the dose prescription and reference dose rate, the

  10. A control study of TACE using high-dosed and routine-dosed iodized oil as a treatment of large hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Zhou Junmin; Zhan Jincheng; Zhang Zhenming

    2005-01-01

    Objective: To investigate the side effects and curative effect in high-dosed lipiodol-transcatheter arterial chemoembolization as a treatment of large hepatocellular carcinoma. Methods: 79 patients with unresectable hepatocellular carcinoma were treated by TACE, and divided into 2 groups. In group A, 39 patients with the tumor sized 7-18cm in diameter, routine-dosed, 10-20ml lipiodol was given in TACE. 40 patients were enrolled in the high-dosed group B, who were given more than 20ml iodized oil in TACE. Results: The First to third year survival rate of group A was 66.7%, 33.3%, 0% respectively,while in group B it was 75%, 45%, 7.5% respectively. The effective rate was 71.7% in Group A and 87.5% in Group B. There was a significant difference between both groups. There was no significant difference of critical side effects and liver function damage between group A and B. Conclusion: High-dosed lipiodol chemoembolization as a treatment of unresectable hepatocellular carcinoma is superior to the routine TACE, especially when the tumor is large and the liver function reserve is good. (authors)

  11. Monitoring of high-radiation areas for the assessment of operational and body doses

    International Nuclear Information System (INIS)

    Chen, T.J.; Tung, C.J.; Yeh, W.W.; Liao, R.Y.

    2004-01-01

    The International Commission on Radiological Protection (ICRP) recommended a system of dose limits for the protection of ionizing radiation. This system was established based on the effective dose, E, and the equivalent dose to an organ or tissue, H T , to assess stochastic and deterministic effects. In radiation protection monitoring for external radiation, operational doses such as the deep dose equivalent index, H I,d , shallow dose equivalent index, H I,s , ambient dose equivalent [1,4-6], H*, directional dose equivalent, H', individual dose equivalent-penetrating, H p , and individual dose equivalent-superficial, H s , are implemented. These quantities are defined in an International Commission on Radiation Units and Measurements (ICRU) sphere and in an anthropomorphic phantom under simplified irradiation conditions. They are useful when equivalent doses are below the corresponding limits. In the case of equivalent doses far below the limits, the exposure or air kerma is commonly applied. For workers exposed to high levels of radiation, accurate assessments of effective doses and equivalent doses may be needed in order to acquire legal and health information. In the general principles of monitoring for radiation protection of workers, ICRP recommended that: 'A graduated response is advocated for the monitoring of the workplace and for individual monitoring - graduated in the sense that a greater degree of monitoring is deemed to be necessary as doses increase of as unpredictability increases. Gradually more complex or realistic procedures should be adopted as doses become higher. Thus, at low dose equivalents (corresponding say to those within Working Condition B) dosimetric quantities might be used directly to assess exposure, since accuracy is not crucial. At intermediate dose equivalents (corresponding say to Working Condition A and slight overexposures) somewhat greater accuracy is warranted, and the conversion coefficients from dosimetric to radiation

  12. Pathophysiology of GPCR Homo- and Heterodimerization: Special Emphasis on Somatostatin Receptors

    Directory of Open Access Journals (Sweden)

    Rishi K. Somvanshi

    2012-04-01

    Full Text Available G-protein coupled receptors (GPCRs are cell surface proteins responsible for translating >80% of extracellular reception to intracellular signals. The extracellular information in the form of neurotransmitters, peptides, ions, odorants etc is converted to intracellular signals via a wide variety of effector molecules activating distinct downstream signaling pathways. All GPCRs share common structural features including an extracellular N-terminal, seven-transmembrane domains (TMs linked by extracellular/intracellular loops and the C-terminal tail. Recent studies have shown that most GPCRs function as dimers (homo- and/or heterodimers or even higher order of oligomers. Protein-protein interaction among GPCRs and other receptor proteins play a critical role in the modulation of receptor pharmacology and functions. Although ~50% of the current drugs available in the market target GPCRs, still many GPCRs remain unexplored as potential therapeutic targets, opening immense possibility to discover the role of GPCRs in pathophysiological conditions. This review explores the existing information and future possibilities of GPCRs as tools in clinical pharmacology and is specifically focused for the role of somatostatin receptors (SSTRs in pathophysiology of diseases and as the potential candidate for drug discovery.

  13. High dose potassium-nitrate chemical dosimeter

    International Nuclear Information System (INIS)

    Dorda de Cancio, E.M.; Munoz, S.S.

    1982-01-01

    This dosimeter is used to control 10 kGY-order doses (1 Mrad). Nitrate suffers a radiolitic reduction phenomena, which is related to the given dose. The method to use potassium nitrate as dosimeter is described, as well as effects of the temperature of irradiation, pH, nitrate concentration and post-irradiation stability. Nitrate powder was irradiated at a Semi-Industrial Plant, at Centro Atomico Ezeiza, and also in a Gammacell-220 irradiator. The dose rates used were 2,60 and 1,80 KGY/hour, and the given doses varied between 1,0 and 150 KGY. The uncertainty was +-3% in all the range. (author) [es

  14. Developing A Directional High-Dose Rate (d-HDR) Brachytherapy Source

    Science.gov (United States)

    Heredia, Athena Yvonne

    Conventional sources used in brachytherapy provide nearly isotropic or radially symmetric dose distributions. Optimizations of dose distributions have been limited to varied dwell times at specified locations within a given treatment volume, or manipulations in source position for seed implantation techniques. In years past, intensity modulated brachytherapy (IMBT) has been used to reduce the amount of radiation to surrounding sensitive structures in select intracavitary cases by adding space or partial shields. Previous work done by Lin et al., at the University of Wisconsin-Madison, has shown potential improvements in conformality for brachytherapy treatments using a directionally shielded low dose rate (LDR) source for treatments in breast and prostate. Directional brachytherapy sources irradiate approximately half of the radial angles around the source, and adequately shield a quarter of the radial angles on the opposite side, with sharp gradient zones between the treated half and shielded quarter. With internally shielded sources, the radiation can be preferentially emitted in such a way as to reduce toxicities in surrounding critical organs. The objective of this work is to present findings obtained in the development of a new directional high dose rate (d-HDR) source. To this goal, 103Pd (Z = 46) is reintroduced as a potential radionuclide for use in HDR brachytherapy. 103Pd has a low average photon energy (21 keV) and relatively short half -life (17 days), which is why it has historically been used in low dose rate applications and implantation techniques. Pd-103 has a carrier-free specific activity of 75000 Ci/g. Using cyclotron produced 103Pd, near carrier-free specific activities can be achieved, providing suitability for high dose rate applications. The evolution of the d-HDR source using Monte Carlo simulations is presented, along with dosimetric parameters used to fully characterize the source. In addition, a discussion on how to obtain elemental

  15. Not So Giants: Mice Lacking Both Somatostatin and Cortistatin Have High GH Levels but Show No Changes in Growth Rate or IGF-1 Levels.

    Science.gov (United States)

    Pedraza-Arévalo, S; Córdoba-Chacón, J; Pozo-Salas, A I; L-López, F; de Lecea, L; Gahete, M D; Castaño, J P; Luque, R M

    2015-06-01

    Somatostatin (SST) and cortistatin (CORT) are two highly related neuropeptides involved in the regulation of various endocrine secretions. In particular, SST and CORT are two primary negative regulators of GH secretion. Consequently, single SST or CORT knockout mice exhibit elevated GH levels; however, this does not lead to increased IGF-1 levels or somatic growth. This apparent lack of correspondence has been suggested to result from compensatory mechanisms between both peptides. To test this hypothesis, in this study we explored, for the first time, the consequences of simultaneously deleting endogenous SST and CORT by generating a double SST/CORT knockout mouse model and exploring its endocrine and metabolic phenotype. Our results demonstrate that simultaneous deletion of SST and CORT induced a drastic elevation of endogenous GH levels, which, surprisingly, did not lead to changes in growth rate or IGF-1 levels, suggesting the existence of additional factors/systems that, in the absence of endogenous SST and CORT, could counteract GH actions. Notably, elevation in circulating GH levels were not accompanied by changes in pituitary GH expression or by alterations in the expression of its main regulators (GHRH and ghrelin) or their receptors (GHRH receptor, GHS receptor, or SST/CORT receptors) at the hypothalamic or pituitary level. However, although double-SST/CORT knockout male mice exhibited normal glucose and insulin levels, they had improved insulin sensitivity compared with the control mice. Therefore, these results suggest the existence of an intricate interplay among the known (SST/CORT), and likely unknown, inhibitory components of the GH/IGF-1 axis to regulate somatic growth and glucose/insulin homeostasis.

  16. Escalation to High Dose Defibrotide in Patients with Hepatic Veno-Occlusive Disease

    Science.gov (United States)

    Triplett, Brandon M.; Kuttab, Hani I.; Kang, Guolian; Leung, Wing

    2015-01-01

    Hepatic veno-occlusive disease (VOD) is a serious complication of high-dose chemotherapy regimens, such as those utilized in hematopoietic cell transplantation recipients. Defibrotide is considered a safe and effective treatment when dosed at 25 mg/kg/day. However, patients who develop VOD still have increased mortality despite the use of defibrotide. Data are limited on the use of doses above 60 mg/kg/day for persistent VOD. In this prospective clinical trial, 34 patients received escalating doses of defibrotide. For patients with persistent VOD despite doses of 60 mg/kg/day, doses were increased to a maximum of 110 mg/kg/day. There was no observed increase in toxicity until doses rose beyond 100 mg/kg/day. Patients receiving doses between 10–100 mg/kg/day experienced an average of 3 bleeding episodes per 100 days of treatment, while those receiving doses >100 mg/kg/day experienced 13.2 bleeding episodes per 100 days (p=0.008). Moreover, dose reductions due to toxicity were needed at doses of 110 mg/kg/day more often than at lower doses. Defibrotide may be safely escalated to doses well above the current standard without an increase in bleeding risk. However, the efficacy of this dose escalation strategy remains unclear, as outcomes were similar to published cohorts of patients receiving standard doses of defibrotide for VOD. PMID:26278046

  17. Pattern of somatostatin receptors expression in normal and bladder cancer tissue samples.

    Science.gov (United States)

    Karavitakis, Markos; Msaouel, Pavlos; Michalopoulos, Vassilis; Koutsilieris, Michael

    2014-06-01

    Known risks factors for bladder cancer progression and recurrence are limited regarding their prognostic ability. Therefore identification of molecular determinants of disease progression could provide with more specific prognostic information and could be translated into new approaches for biomarker development. In the present study we evaluated, the expression patterns of somatostatin receptors 1-5 (SSTRs) in normal and tumor bladder tissues. The expression of SSTR1-5 was characterized in 45 normal and bladder cancer tissue samples using reverse transcriptase-polymerase chain reaction (RT-PCR). SSTR1 was expressed in 24 samples, SSTR2 in 15, SSTR3 in 23, SSTR4 in 16 and SSTR5 in all but one sample. Bladder cancer tissue samples expressed lower levels of SSTR3. Co-expression of SSTRs was associated with superficial disease. Our results demonstrate, for the first time, that there is expression of SSTR in normal and bladder cancer urothelium. Further studies are required to evaluate the prognostic and therapeutic significance of these findings. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  18. Safety aspects of preoperative high-dose glucocorticoid in primary total knee replacement

    DEFF Research Database (Denmark)

    Jørgensen, C C; Pitter, F T; Kehlet, H

    2017-01-01

    Background: Preoperative single high-dose glucocorticoid may have early outcome benefits in total hip arthroplasty (THA) and knee arthroplasty (TKA), but long-term safety aspects have not been evaluated. Methods: From October 2013, the departments reporting to the prospective Lundbeck Foundation....... Conclusions: In this detailed prospective cohort study, preoperative high-dose glucocorticoid administration was not associated with LOS >4 days, readmissions or infectious complications in TKA patients without contraindications....

  19. Analysis of renal impairment in MM-003, a phase III study of pomalidomide + low - dose dexamethasone versus high - dose dexamethasone in refractory or relapsed and refractory multiple myeloma

    Science.gov (United States)

    Weisel, Katja C.; Dimopoulos, Meletios A.; Moreau, Philippe; Lacy, Martha Q.; Song, Kevin W.; Delforge, Michel; Karlin, Lionel; Goldschmidt, Hartmut; Banos, Anne; Oriol, Albert; Alegre, Adrian; Chen, Christine; Cavo, Michele; Garderet, Laurent; Ivanova, Valentina; Martinez-Lopez, Joaquin; Knop, Stefan; Yu, Xin; Hong, Kevin; Sternas, Lars; Jacques, Christian; Zaki, Mohamed H.; Miguel, Jesus San

    2016-01-01

    Pomalidomide + low-dose dexamethasone is effective and well tolerated for refractory or relapsed and refractory multiple myeloma after bortezomib and lenalidomide failure. The phase III trial MM-003 compared pomalidomide + low-dose dexamethasone with high-dose dexamethasone. This subanalysis grouped patients by baseline creatinine clearance ≥ 30 − < 60 mL/min (n=93, pomalidomide + low-dose dexamethasone; n=56, high-dose dexamethasone) or ≥ 60 mL/min (n=205, pomalidomide + low-dose dexamethasone; n=93, high-dose dexamethasone). Median progression-free survival was similar for both subgroups and favored pomalidomide + low-dose dexamethasone versus high-dose dexamethasone: 4.0 versus 1.9 months in the group with baseline creatinine clearance ≥ 30 − < 60 mL/min (P<0.001) and 4.0 versus 2.0 months in the group with baseline creatinine clearance ≥ 60 mL/min (P<0.001). Median overall survival for pomalidomide + low-dose dexamethasone versus high-dose dexamethasone was 10.4 versus 4.9 months (P=0.030) and 15.5 versus 9.2 months (P=0.133), respectively. Improved renal function, defined as an increase in creatinine clearance from < 60 to ≥ 60 mL/min, was similar in pomalidomide + low-dose dexamethasone and high-dose dexamethasone patients (42% and 47%, respectively). Improvement in progression-free and overall survival in these patients was comparable with that in patients without renal impairment. There was no increase in discontinuations of therapy, dose modifications, and adverse events in patients with moderate renal impairment. Pomalidomide at a starting dose of 4 mg + low-dose dexamethasone is well tolerated in patients with refractory or relapsed and refractory multiple myeloma, and of comparable efficacy if moderate renal impairment is present. This trial was registered with clinicaltrials.gov identifier 01311687 and EudraCT identifier 2010-019820-30. PMID:27081177

  20. In phantom calibration of a high dose rate remote afterloading device

    International Nuclear Information System (INIS)

    Alfonso, R.; Tolede, P.; Pich, V.

    1995-01-01

    The high dose-rate (HDR) brachytherapy in Cuba is based on soviet made devices type AGAT-V. In order to calibration one of these for clinical use a method based of the different measurement of absorbed dose at the reference point B in a paraffin phantom was developed. The results of the calibration are shown. From these results an analysis was made of the effective doses to prescription point a considering the Lineal-Quadratic model. The clinical results by using the AGAT-V device are displayed in a comparative way