WorldWideScience

Sample records for high density tape

  1. Sputtered thin films for high density tape recording

    NARCIS (Netherlands)

    Nguyen, L.T.

    This thesis describes the investigation of sputtered thin film media for high density tape recording. As discussed in Chapter 1, to meet the tremendous demand of data storage, the density of recording tape has to be increased continuously. For further increasing the bit density the key factors are:

  2. Development of Bi-based high critical current density superconducting tapes

    International Nuclear Information System (INIS)

    Swaminathan, G.

    1995-01-01

    In order to achieve the aim of developing suitable superconducting materials the main emphasis has to be made in the following areas viz., synthesizing powders, detailed study of sintering and phase conversion process in relation to the critical current density (J c ) on pellets and optimising of tape processing parameters. The bismuth system has been found to be more favourable for making wires and tapes because of its high transition temperature, good stability, does not require oxygen on cooling and is non-toxic. These have been the most convenient properties which made the BiSCO material the most popular one

  3. Spatial variations in composition in high-critical-current-density Bi-2223 tapes

    International Nuclear Information System (INIS)

    Holesinger, T. G.; Bingert, J. F.; Teplitsky, M.; Li, Q.; Parrella, R.; Rupich, M. P.; Riley, G. N. Jr.

    2000-01-01

    A detailed compositional analysis of high-critical-current-density (J c ) (55 and 65 kA/cm2 at 77 K) (Bi, Pb) 2 Sr 2 Ca 2 Cu 3 O y (Bi-2223) tapes was undertaken by energy dispersive spectroscopy in the transmission electron microscope. Structural features were coupled with characteristic compositions of the Bi-2223 phase. The average of all compositional measurements of the Bi-2223 phase was determined to be Bi 1.88 Pb 0.23 Sr 1.96 Ca 1.95 Cu 2.98 O y . However, spatial variations in the Bi-2223 composition and differing phase equilibria were found throughout the filament structure. In particular, a considerable range of Bi-2223 compositions can be found within a single tape, and the lead content of the Bi-2223 phase is significantly depressed in the vicinity of lead-rich phases. The depletion of lead in the Bi-2223 phase around the 3221 phases may be a current-limiting microstructure in these tapes. (c) 2000 Materials Research Society

  4. Methods and systems for fabricating high quality superconducting tapes

    Science.gov (United States)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  5. Methods and systems for fabricating high quality superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  6. Induced critical current density limit of Ag sheathed Bi-2223 tape conductor

    International Nuclear Information System (INIS)

    Ogiwara, H.; Satou, M.; Yamada, Y.; Kitamura, T.; Hasegawa, T.

    1994-01-01

    The authors have already reported the best critical current density of 66,000 A/cm 2 with an Ag sheathed Bi-2223 tape conductor. The Brick-wall model is for explaining the current transport mechanism of this conductor. The model has its roots in the fact that the Bi-2223 tape core is a complicated stack of crystals which have a mica-flake structure. The orientation of the crystals which have a mica-flake structure. The orientation of the crystals seriously affects the current transport capability. Moreover, the contacts between the stacking crystals are very important. The transport current flows dividing into many branch paths. Under high magnetic field, the different paths experienced different electromagnetic forces. Differences between the electromagnetic forces on the different crystals can affect the contacts so as to increase resistivity and decrease overall critical current density of the tape. This effect can foretell the limit of the critical current density obtainable with these kinds of conductors

  7. Engineering Critical Current Density Improvement in Ag- Bi-2223 Tapes

    DEFF Research Database (Denmark)

    Wang, W. G.; Seifi, Behrouz; Eriksen, Morten

    2000-01-01

    Ag alloy sheathed Bi-2223 multifilament tapes were produced by the powder-in-tube method. Engineering critical current density improvement has been achieved through both enhancement of critical current density by control of the thermal behavior of oxide powder and by an increase of the filling...... factor of the tapes. Phase evolution at initial sintering stage has been studied by a quench experiment in Ag-Bi-2223 tapes. The content, texture, and microstructure of various phases were determined by XRD and SEM. A novel process approach has been invented in which square wire was chosen rather than...

  8. Epitaxial YBa2Cu3O7 on biaxially textured (001) Ni: An approach to high critical current density superconducting tapes

    International Nuclear Information System (INIS)

    Norton, D.P.; Goyal, A.; Budai, J.D.

    1997-01-01

    In-plane aligned, c-axis oriented YBa 2 Cu 3 O 7 (YBCO) films with superconducting critical current densities, J c , as high as 700,000 amperes per square centimeter at 77 kelvin have been grown on thermo-mechanically, rolled-textured (001) Ni tapes using pulsed-laser deposition. Epitaxial growth of oxide buffer layers directly on biaxially textured Ni, formed by recrystallization of cold-rolled pure Ni, enables the growth of 1.5 micrometer-thick YBCO films with superconducting properties that are comparable to those observed for epitaxial films on single crystal oxide substrates. This result represents a viable approach for producing long-length superconducting tapes for high current, high field applications at 77 kelvin

  9. Field mapping measurements to determine spatial and field dependence of critical current density in YBCO tapes

    International Nuclear Information System (INIS)

    Leclerc, J.; Berger, K.; Douine, B.; Lévêque, J.

    2013-01-01

    Highlights: • A method for characterizing superconducting tapes from field mapping is presented. • A new and efficient field mapping apparatus has been setup. • This method allows the spatial characterization of superconducting tapes. • The critical current density is obtained as a function of the flux density. • This method has been experimentally tested on an YBCO tape. -- Abstract: In this paper a measurement method that allows the determination of the critical current density of superconducting tape from field mapping measurements is presented. This contact-free method allows obtaining characteristics of the superconductor as a function of the position and of the applied flux density. With some modifications, this technique can be used for reel-to-reel measurements. The determination of the critical current density is based on an inverse calculation. This involves calculating the current distribution in the tape from magnetic measurements. An YBaCuO tape has been characterized at 77 K. A defect in this superconductor has been identified. Various tests were carried out to check the efficiency of the method. The inverse calculation was tested theoretically and experimentally. Comparison with a transport current measurement was also performed

  10. Strongly enhanced current densities in Sr0.6K0.4Fe2As2 + Sn superconducting tapes

    Science.gov (United States)

    Lin, He; Yao, Chao; Zhang, Xianping; Zhang, Haitao; Wang, Dongliang; Zhang, Qianjun; Ma, Yanwei; Awaji, Satoshi; Watanabe, Kazuo

    2014-03-01

    Improving transport current has been the primary topic for practical application of superconducting wires and tapes. However, the porous nature of powder-in-tube (PIT) processed iron-based tapes is one of the important reasons for low critical current density (Jc) values. In this work, the superconducting core density of ex-situ Sr0.6K0.4Fe2As2 + Sn tapes, prepared from optimized precursors, was significantly improved by employing a simple hot pressing as an alternative route for final sintering. The resulting samples exhibited optimal critical temperature (Tc), sharp resistive transition, small resistivity and high Vickers hardness (Hv) value. Consequently, the transport Jc reached excellent values of 5.1 × 104 A/cm2 in 10 T and 4.3 × 104 A/cm2 in 14 T at 4.2 K, respectively. Our tapes also exhibited high upper critical field Hc2 and almost field-independent Jc. These results clearly demonstrate that PIT pnictide wire conductors are very promising for high-field magnet applications.

  11. Current distribution and enhancement of the engineering critical current density in multifilament Bi-2223 tapes

    DEFF Research Database (Denmark)

    Wang, W.G.; Jensen, M.B.; Kindl, B.

    2000-01-01

    The spatial distribution of the critical current density (Jc) and engineering critical current density (Je) along the tape width direction was studied by a cutting technique on Bi-2223 multifilamentary tapes. In general, an increase of Jc towards the centre of the tape was measured. We attribute...... microstructure with a great amount of secondary phases. Local variation of Jc was measured within the centre segment of the tape. This indicates the influence of other factors on Jc, such as filament shape, connectivity of the filaments, and sausaging. Enhancement of Je has been pursued in which average Je of 12...

  12. High Density Digital Data Storage System

    Science.gov (United States)

    Wright, Kenneth D., II; Gray, David L.; Rowland, Wayne D.

    1991-01-01

    The High Density Digital Data Storage System was designed to provide a cost effective means for storing real-time data from the field-deployable digital acoustic measurement system. However, the high density data storage system is a standalone system that could provide a storage solution for many other real time data acquisition applications. The storage system has inputs for up to 20 channels of 16-bit digital data. The high density tape recorders presently being used in the storage system are capable of storing over 5 gigabytes of data at overall transfer rates of 500 kilobytes per second. However, through the use of data compression techniques the system storage capacity and transfer rate can be doubled. Two tape recorders have been incorporated into the storage system to produce a backup tape of data in real-time. An analog output is provided for each data channel as a means of monitoring the data as it is being recorded.

  13. Effect of a superconducting coil as a fault current limiter on current density distribution in BSCCO tape after an over-current pulse

    International Nuclear Information System (INIS)

    Tallouli, M; Yamaguchi, S.; Shyshkin, O.

    2017-01-01

    The development of power transmission lines based on long-length high temperature superconducting (HTS) tapes is complicated and technically challenging task. A serious problem for transmission line operation could become HTS power cable damage due to over-current pulse conditions. To avoid the cable damage in any urgent case the superconducting coil technology, i.e. superconductor fault current limiter (SFCL) is required. Comprehensive understanding of the current density characteristics of HTS tapes in both cases, either after pure over-current pulse or after over-current pulse limited by SFCL, is needed to restart or to continue the operation of the power transmission line. Moreover, current density distribution along and across the HTS tape provides us with the sufficient information about the quality of the tape performance in different current feeding regimes. In present paper we examine BSCCO HTS tape under two current feeding regimes. The first one is 100A feeding preceded by 900A over-current pulse. In this case none of tape protection was used. The second scenario is similar to the fist one but SFCL is used to limit an over-current value. For both scenarios after the pulse is gone and the current feeding is set up at 100A we scan magnetic field above the tape by means of Hall probe sensor. Then the feeding is turned of and the magnetic field scanning is repeated. Using the inverse problem numerical solver we calculate the corresponding direct and permanent current density distributions during the feeding and after switch off. It is demonstrated that in the absence of SFCL the current distribution is highly peaked at the tape center. At the same time the current distribution in the experiment with SFCL is similar to that observed under normal current feeding condition. The current peaking in the first case is explained by the effect of an opposite electric field induced at the tape edges during the overcurrent pulse decay, and by degradation of

  14. High critical currents in heavily doped (Gd,Y)Ba2Cu3Ox superconductor tapes

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V; Gharahcheshmeh, MH; Xu, A; Galstyan, E; Delgado, L; Cantoni, C

    2015-01-19

    REBa2Cu3Ox ((REBCO), RE = rare earth) superconductor tapes with moderate levels of dopants have been optimized for high critical current density in low magnetic fields at 77 K, but they do not exhibit exemplary performance in conditions of interest for practical applications, i.e., temperatures less than 50K and fields of 2-30 T. Heavy doping of REBCO tapes has been avoided by researchers thus far due to deterioration in properties. Here, we report achievement of critical current densities (J(c)) above 20 MA/cm(2) at 30 K, 3 T in heavily doped (25 mol.% Zr-added) (Gd,Y)Ba2Cu3Ox superconductor tapes, which is more than three times higher than the J(c) typically obtained in moderately doped tapes. Pinning force levels above 1000 GN/m(3) have also been attained at 20 K. A composition map of lift factor in J(c) (ratio of J(c) at 30 K, 3 T to the J(c) at 77 K, 0 T) has been developed which reveals the optimum film composition to obtain lift factors above six, which is thrice the typical value. A highly c-axis aligned BaZrO3 (BZO) nanocolumn defect density of nearly 7 x 10(11) cm(-2) as well as 2-3 nm sized particles rich in Cu and Zr have been found in the high J(c) films. (C) 2015 AIP Publishing LLC.

  15. The inhomogeneities of (Pb,Bi)2223 superconducting tapes and their detection

    International Nuclear Information System (INIS)

    Leeuwen, S. van

    1999-05-01

    This thesis consists of two parts: first, the inhomogeneities that were observed in high temperature superconducting (Pb,Bi)2223 tapes were studied followed by the design of two rigs which were built to detect them. These investigations concentrated on (Pb,Bi)2223 phase high temperature superconducting tapes. Superconductors and their applications were briefly evaluated. It was found that high temperature superconductors have unique properties which cannot be duplicated by their counterparts. However, it was noted that there are significant improvements to be made before they can be commercially viable. An investigation was carried out into the variation of core density within cross sections and along lengths of (Pb,Bi)2223 tapes during fabrication. It was observed that rolling and thermal treatment brought about a non-uniform core density in both these aspects of tile tape. This was followed by an investigation into the effect of core density on the formation of the (Pb,Bi)2223 phase. It was shown that a high core density formed the (Pb,Bi)2223 phase at a slower rate than a lower core density under the thermal treatment. A high core density and a slow heating rate produced smaller 2212 grains at the end of the incubation period. Smaller 2212 grains were thought to be linked to the faster formation of the (Pb,B1)2223 phase. The highest Jc was from a high core density tape which had the smaller 2212 grains at the end of incubation period. Smaller 2212 grains were thought to aid a more homogeneous conversion to the (Pb,Bi)2223 phase. Alloy-sheathed (Pb,Bi)2223 superconducting tapes were produced in order to fabricate a more homogeneous core density. It was found that the alloy sheath (with an addition of 15% wt Ag in the precursor powder) changed the characteristics of the core in several ways: the formation of the (Pb,Bi)2223 phase was homogeneous across the thickness of the core, a smaller 2212 grain size was formed at the end of the incubation period and a higher

  16. High critical currents in heavily doped (Gd,Y)Ba2Cu3Ox superconductor tapes

    International Nuclear Information System (INIS)

    Selvamanickam, V.; Gharahcheshmeh, M. Heydari; Xu, A.; Galstyan, E.; Delgado, L.; Cantoni, C.

    2015-01-01

    REBa 2 Cu 3 O x ((REBCO), RE = rare earth) superconductor tapes with moderate levels of dopants have been optimized for high critical current density in low magnetic fields at 77 K, but they do not exhibit exemplary performance in conditions of interest for practical applications, i.e., temperatures less than 50 K and fields of 2–30 T. Heavy doping of REBCO tapes has been avoided by researchers thus far due to deterioration in properties. Here, we report achievement of critical current densities (J c ) above 20 MA/cm 2 at 30 K, 3 T in heavily doped (25 mol. % Zr-added) (Gd,Y)Ba 2 Cu 3 O x superconductor tapes, which is more than three times higher than the J c typically obtained in moderately doped tapes. Pinning force levels above 1000 GN/m 3 have also been attained at 20 K. A composition map of lift factor in J c (ratio of J c at 30 K, 3 T to the J c at 77 K, 0 T) has been developed which reveals the optimum film composition to obtain lift factors above six, which is thrice the typical value. A highly c-axis aligned BaZrO 3 (BZO) nanocolumn defect density of nearly 7 × 10 11  cm −2 as well as 2–3 nm sized particles rich in Cu and Zr have been found in the high J c films

  17. Comparison study of cable geometries and superconducting tape layouts for high-temperature superconductor cables

    Science.gov (United States)

    Ta, Wurui; Shao, Tianchong; Gao, Yuanwen

    2018-04-01

    High-temperature superconductor (HTS) rare-earth-barium-copper-oxide (REBCO) tapes are very promising for use in high-current cables. The cable geometry and the layout of the superconducting tapes are directly related to the performance of the HTS cable. In this paper, we use numerical methods to perform a comparison study of multiple-stage twisted stacked-tape cable (TSTC) conductors to find better cable structures that can both improve the critical current and minimize the alternating current (AC) losses of the cable. The sub-cable geometry is designed to have a stair-step shape. Three superconducting tape layouts are chosen and their transport performance and AC losses are evaluated. The magnetic field and current density profiles of the cables are obtained. The results show that arrangement of the superconducting tapes from the interior towards the exterior of the cable based on their critical current values in descending order can enhance the cable's transport capacity while significantly reducing the AC losses. These results imply that cable transport capacity improvements can be achieved by arranging the superconducting tapes in a manner consistent with the electromagnetic field distribution. Through comparison of the critical currents and AC losses of four types of HTS cables, we determine the best structural choice among these cables.

  18. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V; Chen, Y; Shi, T; Liu, Y; Khatri, ND; Liu, J; Yao, Y; Xiong, X; Lei, C; Soloveichik, S; Galstyan, E; Majkic, G

    2013-01-21

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba2Cu3Ox film. By a modified MOCVD process,enhanced critical current densities have been achieved with high levels of Zr addition,including 3.83 MA cm(-2) in 15 at.% Zr- added 1.1 mu m thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/ 12 mm have been reached in (Gd,Y) BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape,corresponding to a pinning force value of 268 GN m(-3). The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second- phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met.

  19. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    International Nuclear Information System (INIS)

    Selvamanickam, V; Shi, T; Liu, Y; Khatri, N D; Liu, J; Yao, Y; Galstyan, E; Majkic, G; Chen, Y; Xiong, X; Lei, C; Soloveichik, S

    2013-01-01

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba 2 Cu 3 O x film. By a modified MOCVD process, enhanced critical current densities have been achieved with high levels of Zr addition, including 3.83 MA cm −2 in 15 at.% Zr-added 1.1 μm thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/12 mm have been reached in (Gd,Y)BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape, corresponding to a pinning force value of 268 GN m −3 . The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second-phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met. (paper)

  20. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    Science.gov (United States)

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  1. Preparation of (Bi, Pb)-2223/Ag tapes by high temperature sintering and post-annealing process

    DEFF Research Database (Denmark)

    Hua, L.; Grivel, Jean-Claude; Andersen, L.G.

    2002-01-01

    A novel heat treatment process was developed to fabricate (Bi, Pb)-2223/Ag tapes with high critical current density (J(c)). The process can be divided into two parts: reformation and post-annealing. Tapes were first heated to the maximum temperature (830-860 degreesC) followed by slow cooling...... (reformation). Then, tape, were annealed between 760 and 820 degreesC (post-annealing). Reformation is expected to produce a large amount of liquid phase which may heat microcracks, decrease porosity, and improve grain growth. However, since the sintering temperature is beyond the Bi-2223 single-phase region......-energy synchrotron XRD and SEM/EDX. Some process parameters e.g. sintering temperature. cooling rate. and post-annealing time were optimised. (C) 2002 Elsevier Science B.V. All rights reserved....

  2. ac loss and dc critical current densities of Nb3Sn tapes by the solid state diffusion process

    International Nuclear Information System (INIS)

    Suenaga, M.; Klamut, C.; Bussiere, J.F.

    1976-01-01

    The effects of metallurgical processing on 60 Hz ac losses and dc critical currents in Nb 3 Sn tapes fabricated by the solid state diffusion technique were investigated. An addition of Al to the Cu--Sn alloy for the matrix resulted in large reduction in the ac losses of Nb 3 Sn tapes, but the highest linear critical current densities were observed in Nb 3 Sn tapes produced with a Nb-1 wt percent Zr core in a Cu-13 wt percent Sn matrix. Values of the losses and the critical currents in these tapes can meet the present requirements for the ac superconducting power cables

  3. Improvements of fabrication processes and enhancement of critical current densities in (Ba,K)Fe2As2 HIP wires and tapes

    Science.gov (United States)

    Pyon, Sunseng; Suwa, Takahiro; Tamegai, Tsuyoshi; Takano, Katsutoshi; Kajitani, Hideki; Koizumi, Norikiyo; Awaji, Satoshi; Zhou, Nan; Shi, Zhixiang

    2018-05-01

    We fabricated (Ba,K)Fe2As2 superconducting wires and tapes using the powder-in-tube method and hot isostatic pressing (HIP). HIP wires and tapes showed a high value of transport critical current density (J c) exceeding 100 kAcm‑2 at T = 4.2 K and the self-field. Transport J c in the HIP wire reached 38 kAcm‑2 in a high magnetic field of 100 kOe. This value is almost twice larger than the previous highest value of J c among round wires using iron-based superconductors. Enhancement of J c in the wires and tapes was caused by improvement of the drawing process, which caused degradation of the core, formation of microcracks, weak links between grains, and random orientation of grains. Details of the effect of the improved fabrication processes on the J c are discussed.

  4. Tape edge study in a linear tape drive with single-flanged guides

    International Nuclear Information System (INIS)

    Goldade, A.V.; Bhushan, Bharat

    2004-01-01

    Improved tape guiding and tape dimensional stability are essential for magnetic tape linear recoding formats to take advantage of vastly increased track density and thereby achieve higher storage capacities. Tape guiding is dependent on numerous parameters, such as type of the guides and tape path geometry, quality of virgin tape edge, drive operating parameters (e.g., tape speed and tape tension), mechanical properties of the tape, and tape geometry (e.g., cupping and curvature). The objective of the present study is to evaluate guiding and tribological performance of single-flanged guides with porous air bearings in a linear tape drive. A comparison of guiding performance of the dual flanged stationary guides and single-flanged guides with porous air bearings is performed. The effect of tape path geometry, drive operating conditions (speed and tension) and tape edge quality of factory-slit tapes on tape guiding are evaluated during short-term tests. A lateral force measurement technique is used to measure the force exerted by the tape edge on the guide flange. A technique for the lateral tape motion measurement is used to study the effect of continuous sliding on tape guiding. Wear tests up to 5000 cycles are conducted and coefficient of friction and lateral tape motion are monitored to study the effect of drive operating conditions (speed and tension), edge quality of factory-slit tapes and tape thickness on tape guiding. Optical microscopy, atomic force microscopy and scanning electron microscopy are employed to study and quantify the quality of tape edge

  5. Final report: High current capacity high temperature superconducting film based tape for high field magnets

    International Nuclear Information System (INIS)

    Ying Xin

    2000-01-01

    The primary goal of the program was to establish the process parameters for the continuous deposition of high quality, superconducting YBCO films on one meter lengths of buffered RABiTS tape using MOCVD and to characterize the potential utility of the resulting tapes in high field magnet applications

  6. Optimization of superconductivity properties in MgB2 Wires and tapes to generate high magnetic fields

    International Nuclear Information System (INIS)

    Serrano, German

    2005-01-01

    We present, in this work, a study of the effects of doping, heat treatments and mechanisms of deformation, over the microstructure and superconducting properties of powder in tube (PIT) M g B 2 wires and tapes.We observed that nano-SiC doping improves the critical current density (J c ) and the upper critical field (H c 2).The combined use of doping and Hot Isostatic Pressing (HIPing), produces samples with high density and improves J c s.We studied the influence of number and temperature of intermediate heat treatments (TTI), during the fabrication of wires and tapes.We observed that TTI made at low temperature ( o C), results in wires and tapes with better microstructure than those made at high temperature.Moreover, the increment of the heat treatments numbers at high temperature, decreases the quality of microstructure and J c .In the study of sheaths materials, we observed that the J c values measured by magnetization in Ti sheath samples are two order of magnitude larger than the values measured by transport, which indicates macroscopic fracture problems.On other hand, we fabricated tapes with excellent J c values (10 4 A/cm 2 at 4K and 7T), which are similar to those of samples made with HIPing.This tape presents some degree of grains alignment, as a consequence of rolling.We observed J c anisotropy in both transport and magnetization measurements in a range between 4 and 26K, and the same effect in H c 2.The anisotropy factor in Jc increase with applied field, while the anisotropy in Hc2 is constant with temperature (H c 2 parallel H c 2 perpendicular ∼1.2).Finally, we observed that carbon nanotubes doping improves H c 2 and this effects is most important at temperatures below 5K.This increase in H c 2 was predicted by Gurevich [45], as an effect of modification in scattering coefficient between electronics bands of M g B 2 by doping [es

  7. High critical currents in heavily doped (Gd,Y)Ba{sub 2}Cu{sub 3}O{sub x} superconductor tapes

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V., E-mail: selva@uh.edu; Gharahcheshmeh, M. Heydari; Xu, A.; Galstyan, E.; Delgado, L. [Department of Mechanical Engineering and Texas Center for Superconductivity, University of Houston, 4800 Calhoun Rd., Houston, Texas 77204-4006 (United States); Cantoni, C. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37381 (United States)

    2015-01-19

    REBa{sub 2}Cu{sub 3}O{sub x} ((REBCO), RE = rare earth) superconductor tapes with moderate levels of dopants have been optimized for high critical current density in low magnetic fields at 77 K, but they do not exhibit exemplary performance in conditions of interest for practical applications, i.e., temperatures less than 50 K and fields of 2–30 T. Heavy doping of REBCO tapes has been avoided by researchers thus far due to deterioration in properties. Here, we report achievement of critical current densities (J{sub c}) above 20 MA/cm{sup 2} at 30 K, 3 T in heavily doped (25 mol. % Zr-added) (Gd,Y)Ba{sub 2}Cu{sub 3}O{sub x} superconductor tapes, which is more than three times higher than the J{sub c} typically obtained in moderately doped tapes. Pinning force levels above 1000 GN/m{sup 3} have also been attained at 20 K. A composition map of lift factor in J{sub c} (ratio of J{sub c} at 30 K, 3 T to the J{sub c} at 77 K, 0 T) has been developed which reveals the optimum film composition to obtain lift factors above six, which is thrice the typical value. A highly c-axis aligned BaZrO{sub 3} (BZO) nanocolumn defect density of nearly 7 × 10{sup 11 }cm{sup −2} as well as 2–3 nm sized particles rich in Cu and Zr have been found in the high J{sub c} films.

  8. Phthalocyanine doping to improve critical current densities in MgB2 tapes

    International Nuclear Information System (INIS)

    Zhang Xianping; Ma Yanwei; Wang Dongliang; Gao Zhaoshun; Wang Lei; Qi Yanpeng; Awaji, Satoshi; Watanabe, Kazuo; Mossang, Eric

    2009-01-01

    Phthalocyanine-doped MgB 2 tapes were prepared by the in situ powder-in-tube method. The relationships between the critical current properties, crystallinity and microstructure were studied as a function of the phthalocyanine doping level. It is found that both H irr and H c2 were improved when MgB 2 samples were doped with phthalocyanine, which are mainly attributed to the effective carbon substitution and enhanced flux pinning strength caused by very fine grain sizes. Furthermore, compared to pure samples, the MgO content remained almost unchanged in all doped tapes, which is very beneficial to having better grain connectivity in MgB 2 . Significantly improved J c was obtained in the phthalocyanine-doped MgB 2 tapes, especially under high magnetic fields.

  9. Fast neutron induced flux pinning in Tl-based high-Tc single crystals and thin films, highly textured tapes and melt-textured bulk 123-superconductors

    International Nuclear Information System (INIS)

    Brandstaetter, G.; Samadi Hosseinalli, G.; Kern, C.; Sauerzopf, F.M.; Schulz, G.W.; Straif, W.; Yang, X.; Weber, H.W.; Hu, Q.Y.

    1999-01-01

    Various compounds (TI-2223, TI-1223, TI-2212) as well as material forms (single crystals, thin films, ceramics, tapes) of TI-based high temperature superconductors were investigated by magnetic and transport techniques. TI-2223 has a very 'low lying' irreversibility line (H parallel e) and negligible critical current densities J c at 77 K. However, the irreversibility line shifts to higher fields and temperatures and J c is strongly enhanced, even at 77 K, after fast neutron irradiation. In contrast, the related TI-1223 compound has a much steeper irreversibility line (H parallel c) similar to that of Y-123. J c is significant up to 77 K, even in the unirradiated state, and can be largely improved by neutron irradiation. Transport measurements made on TI-1223 tapes still show much lower critical current densities. TI-2212 and Tl-2223 thin films have J c 's at 77 K, which are comparable to those of TI-1223 single crystals. Transport measurements on highly textured Bi-2223 tapes as well as flux profile measurements on Nd-123 bulk superconductors confirm the beneficial effects of neutron induced defects (collision cascades) for flux pinning. (author)

  10. Tape write-efficiency improvements in CASTOR

    International Nuclear Information System (INIS)

    Murray, S; Bahyl, V; Cancio, G; Cano, E; Lo Presti, G; Lo Re, G; Ponce, S; Kotlyar, V

    2012-01-01

    The CERN Advanced STORage manager (CASTOR) is used to archive to tape the physics data of past and present physics experiments. For reasons of physical storage space, all of the tape resident data in CASTOR are repacked onto higher density tapes approximately every two years. Improving the performance of writing files smaller than 2GB to tape is essential in order to keep the time needed to repack all of the tape resident data within a period of no more than 1 year. This paper reports on the solution to writing efficiently to tape that is currently in its early deployment phases at CERN.

  11. Fabrication of high edge-definition steel-tape gratings for optical encoders

    Science.gov (United States)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  12. Tape casting and partial melting of Bi-2212 thick films

    Energy Technology Data Exchange (ETDEWEB)

    Buhl, D.; Lang, T.; Heeb, B. [Nichtmetallische Werkstoffe, Zuerich (Switzerland)] [and others

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density of 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).

  13. IBM 3480 tape cartridge

    CERN Multimedia

    1984-01-01

    The 3480 tape format is a magnetic tape data storage format developed by IBM. The cartridge contains a single reel. IBM’s 3480 cartridge tape system sought to replace the traditional reels of magnetic tape in the computer center. Because of their speed, reliability, durability and low media cost, these tapes and tape drives are still in high demand. A hallmark of the genre is transferability. Tapes recorded with one tape drive are generally readable on another drive, even if the tape drives were built by different manufacturers.

  14. Development of microstructure and superconductivity of silver-clad Bi(2223) composite tapes in the process of heat treatment

    International Nuclear Information System (INIS)

    Guo, Y.C.; Liu, H.K.; Dou, S.X.

    1994-01-01

    A systematic study on the development of phase composition, microstructure and superconducting properties (critical temperature Tc and critical current density J c ) in silver-clad (Bi,Pb) 2 Sr 2 Ca 2 Cu 3 O 10 composite tapes during the process of heat treatment has been conducted using X-ray diffraction, scanning electron microscopy and electrical measurements. The correlation between the tape's high Tc phase purity, microstructure and superconducting properties at different heat treatment stages has been carefully analysed and explained. The results indicate that pure high Tc phase, high degree of grain alignment, high mass density and good connection between grains are all essential for superconducting tapes to carry a large current. With the optimized process parameters, a critical current density J c up to 32665 A cm -2 (corresponding critical current, 42.3 A) at 77 K and self-magnetic field for silver-clad (Bi,Pb) 2 Sr 2 Ca 2 Cu 3 O 10 superconducting composite tapes has been achieved. (orig.)

  15. Enhancement of critical current density of in situ processed MgB sub 2 tapes by WB addition

    CERN Document Server

    Fujii, H; Kumakura, H

    2003-01-01

    The effect of tungsten boride (WB) addition on the microstructure and superconducting properties of Fe-sheathed MgB sub 2 tapes has been investigated. The microstructure was not influenced appreciably by the addition, whereas the superconducting properties changed. Even by a 5 mol% addition, the critical temperature (T sub c) decreased by about 0.5 K. However, the field dependence of the inductive critical current density (J sub c sub i) became smaller with the increase in the amount of addition, suggesting that pinning centres effective in a high-field region were possibly introduced. The transport critical current density (J sub c sub t) at 4.2 K increased about twice by the 5 mol% addition and reached 15 and 5 kA cm sup - sup 2 at 8 and 10 T, respectively.

  16. Increasing the efficiency of tape-based storage backends

    CERN Document Server

    Bessone, N; Murray, S; Taurelli, G; CERN. Geneva. IT Department

    2010-01-01

    HSM systems such as the CERN’s Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for incre...

  17. Effects of ultrasound therapy with taping PNF training and PNF training with taping in treatment and rehabilitation of sports injuries of high ankle sprain

    Directory of Open Access Journals (Sweden)

    D L Charly Daniel

    2017-01-01

    Conclusions: It was concluded that combining ultrasound with taping and PNF training with taping were found to be more beneficial in the treatment and rehabilitation of high ankle sprain injury. The combined effect of UT, PNF training, and taping may be explored by future researchers.

  18. Percolation modelling for highly aligned polycrystalline superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Rutter, N A; Glowacki, B A; Evetts, J E [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); IRC in Superconductivity, Madingley Road, Cambridge CB3 0HE (United Kingdom)

    2000-11-01

    Surface and bulk texture measurements have been carried out on highly aligned NiFe tapes, suitable for use as coated conductor substrates. Data from small-area electron backscatter diffraction measurements are compared with those from bulk x-ray analysis in the development of a two-dimensional percolation model, and the two are shown to give very similar results. No evidence of grain-to-grain correlation is found. The model is then developed to assess how the properties of a superconducting layer grown epitaxially on buffered tapes will depend on parameters such as sample size, grain size and the extent of grain alignment. (author)

  19. Synergistic reinforcement of highly oriented poly(propylene) tapes by sepiolite nanoclay

    NARCIS (Netherlands)

    Bilotti, E.; Deng, H.; Zhang, R.; Lu, D.; Bras, W.; Fischer, H.R.; Peijs, T.

    2010-01-01

    This paper reports the properties of highly oriented nanocomposite tapes based on isotactic PP and needle-like sepiolite nanoclay, obtained by a solid state drawing process. The intrinsic 1D character of sepiolite allows its exploitation in 1D objects, such as oriented polymer fibres and tapes,

  20. Fabrication of laminated Bi-2212/Ag multifilamentary tape

    Science.gov (United States)

    Yuan, D.-W.; Majer, W. J.; Francavilla, T. L.

    2000-03-01

    The powder-in-tube (PIT) process has been successfully used to make long lengths of Ag-sheathed oxide superconductors. A modified PIT approach is proposed to fabricate conductors with laminated Bi-2212 configurations. Ag/Bi-2212 tapes consisting of seven laminae were produced with various thicknesses ranging from 0.38 to 0.25 mm. The use of a turkshead was found to be beneficial, yielding tapes with good dimensional integrity and consistency. Critical current density (Jc ) values greater than 105 A cm-2 (0.01 T and Bicons/Journals/Common/perp" ALT="perp" ALIGN="TOP"/> tape surface) have been attained for tapes of different thicknesses. Nonetheless, Jc was found to be related to the average thickness of individual Bi-2212 lamina. It is believed that excessive cold working accounts for the decrease in Jc with decreasing size below a threshold value. The enhancement of Jc is attributed to the high Bi-2212 grain alignment along the Ag-oxide interfaces and uniform dimensions within the laminate conductors.

  1. Increasing the efficiency of tape-based storage backends

    International Nuclear Information System (INIS)

    Bessone, Nicola; Cancio, German; Murray, Steve; Taurelli, Giulia

    2010-01-01

    HSM systems such as the CERN's Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for increasing the performance of repacking data from old to newer generation tape media with substantially reduced hardware costs. In this paper, we will describe the improvements for migration policies and priorities, as well as the proposed tape format and the changes which will be applied to the architecture of the CASTOR mass storage system.

  2. Tape casting fluorinated YBC123

    International Nuclear Information System (INIS)

    Taylor, J.A.T.; Luke, D.M.; Whiteley, B.A.

    1991-01-01

    Tape casting the superconducting Ba-Y-Cu oxide was accomplished by several laboratories and show promise for being a versatile forming technique. The major problem is low current density, probably due to lack of grain alignment and grain boundary related weak links. The latter problem may be due to formation of carbonates and hydroxides during binder burnout. Preliminary work done at Alfred shows that a bimodal powder size distribution displays significant alignment after tape casting and that F treated powder is resistant to attack by steam at 100C. Such corrosion resistant powder cast as form tape should survive the binder burnout without the detrimental grain boundary phases that develop from reaction of the superconducting phase, steam and carbon dioxide. This paper presents the results of an investigation of tape casting fluorinated powder with a bimodal size distribution

  3. Design and Test of a Thermal Triggered Persistent Current System using High Temperature Superconducting Tapes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Keun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Kang, Hyoungku [Electro-Mechanical Research Institute, Hyundai Heavy Industries, Yongin (Korea, Republic of); Ahn, Min Cheol [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yang, Seong Eun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yoon, Yong Soo [Department of Electrical Engineering, Ansan College of Technology, 671 Choji-Dong, Danwon-Gu, Ansan, 425-792 (Korea, Republic of); Lee, Sang Jin [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Ko, Tae Kuk [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of)

    2006-06-01

    A superconducting magnet which is operated in persistent current mode in SMES, NMR, MRI and MAGLEV has many advantages such as high uniformity of magnetic field and reduced thermal loss. A high temperature superconducting (HTS) persistent current switch (PCS) system was designed and tested in this research. The HTS PCS was optimally designed using two different HTS tapes, second generation coated conductor (CC) HTS tape and Bi-2223 HTS tape by the finite element method (FEM) in thermal quench characteristic view. The CC tape is more prospective applicable wire in these days for its high n value and critical current independency from external magnetic field than Bi-2223 tape. Also a prototype PCS system using Bi-2223 tape was manufactured and tested. The PCS system consists of a PCS part, a heater which induces the PCS to quench, and a superconducting magnet. The test was performed in various conditions of transport current. An initial current decay appeared when the superconducting magnet was energized in a PCS system was analyzed. This paper would be foundation of HTS PCS researches.

  4. Diagnostics of sources of disturbances and distribution of vibrations over the width of a tape in tape-feed mechanisms

    Science.gov (United States)

    Kenstavichyus, A. B. B.

    1973-01-01

    Disturbances created by certain assemblies and components of tape-feed mechanisms (TFM) and acting on a moving magnetic tape are studied. The method, based on elements of digital logic, is established by stress-strain diagrams of the longitudinal deformations and vibrations across the width of a magnetic tape. Experimental studies were carried out for determination of the functional relationships of longitudinal deformations in a section of magnetic tape to the magnitude of roller play, tension vibrations rate of movement, and elasticity of magnetic tapes. A block diagram of the measurements is shown. Appropriate digital computer algorithms and programs were proposed for statistical analysis of the data obtained. Estimates of the mathematical expectation, dispersion, intercorrelation function, energy spectral density, and distribution pattern of the random process values were calculated.

  5. Fabrication, properties, and microstructures of high Tc tapes and coils made from Ag-clad Bi-2223 superconductors

    International Nuclear Information System (INIS)

    Balachandran, U.; Iyer, A.N.; Youngdahl, C.A.; Motowidlo, L.R.; Hoehn, J.G.; Haldar, P.

    1993-07-01

    Bi-2223 precursor powders were prepared via a solid-state reaction using carbonates and oxides of Bi, Pb, Sr, Ca, and Cu. Results indicate that an in-situ reaction between constituent phases with tho formation of a transient liquid that is consumed during final heat treatment, is essential to obtain increased density with greater connectivity between the 2223 grains. Relative amounts of the constituent phases were adjusted in the powder by varying the calcination conditions, and the powder was then used to fabricate Ag-clad tapes by a powder-in-tube technique. By improving process conditions, transport critical current density (J c ) values greater than 4 x 10 4 A/cm 2 at 77 K and 2 x 10 5 A/cm 2 at 4.2 and 27 K have been obtained in short tape samples. Long tapes were cut into lengths upto 10 m long and used in parallel to fabricate small superconducting pancake coils. The coils were characterized at 77, 27 and 4.2 K and results are discussed

  6. Three-dimensional modelling of metal evaporated tape

    International Nuclear Information System (INIS)

    Kay, G.E.

    1999-06-01

    As developments in magnetic recording increase, the demands for high density recording media continue to rise. One particular medium developed towards meeting these needs is the commercially successful metal evaporated (ME) tape. To provide a deeper understanding of the magnetic processes occurring in recording media, theoretical studies are carried out to complement experimental observations. Therefore, this thesis is concerned with developing a micromagnetic model to simulate the magnetic behaviour of ME tape. ME tape consists of bundles of granular columns which are tilted towards the film normal. The morphology of the film influences the magnetic behaviour and a 3D model is developed in this thesis to represent the columnar structure and the granular nature of ME tape. A Monte Carlo algorithm, consisting of a 'move and grow' procedure, is developed to generate an irregular system of spherical grains whose radii were generated from a log-normal distribution. This structure provides the foundation for modelling columns of ME tape. Initially an isolated column of ME tape was investigated. Grains were considered to be single domain and the dynamic process of the magnetic moments was explored by the Landau-Lifschitz equation. The model demonstrated that as the strength of the exchange coupling parameter increased, then moments which were strongly coupled resisted large negative fields and square hysteresis loops with a high coercivity were produced. Reversal of the moments was observed to be initiated at the ends of a column and then propagated throughout the column. This was attributed to large demagnetising fields and was particularly evident in the model with aligned easy axes. If the easy axes were randomly orientated then more disorder was present in the model and moments rotated incoherently. This produced hysteresis loops that were less square than those of the aligned model. The results also showed how the microstructure influenced the reversal processes

  7. High transport current superconductivity in powder-in-tube Ba0.6K0.4Fe2As2 tapes at 27 T

    Science.gov (United States)

    Huang, He; Yao, Chao; Dong, Chiheng; Zhang, Xianping; Wang, Dongliang; Cheng, Zhe; Li, Jianqi; Awaji, Satoshi; Wen, Haihu; Ma, Yanwei

    2018-01-01

    The high upper critical field and low anisotropy of iron-based superconductors (IBS) make them particularly attractive for high-field applications, especially for the construction of next-generation nuclear magnetic resonance spectrometers, particle accelerators and high-field magnets. However, for practical use it is essential to make IBS materials into wire and tape conductors with sufficient current carrying capability, which is limited by misaligned grains inside the conductors. Here, based on a simple and low-cost powder-in-tube (PIT) method, we demonstrate a high transport critical current density (J c) reaching 1.5 × 105 A cm-2 (I c = 437 A) at 4.2 K and 10 T in Ba0.6K0.4Fe2As2 (Ba-122) tapes by texturing the grain orientation with optimized hot-press technique. The transport J c measured at 4.2 K under high magnetic fields of 27 T is still on the level of 5.5 × 104 A cm-2. Moreover, at 20 K and 5 T the transport J c is also as high as 5.4 × 104 A cm-2, showing a promising application potential in moderate temperature range which can be reached by liquid hydrogen or cryogenic cooling. All these J c values are the highest ever reported for IBS wires and tapes. The high-performance PIT Ba-122 tapes in this work suggest IBS to be a strong potential competitor of cuprate superconductors for the race of high-field applications in the future.

  8. Prototype high-speed tape target transport for a laser plasma soft-x-ray projection lithography source

    International Nuclear Information System (INIS)

    Haney, S.J.; Berger, K.W.; Kubiak, G.D.; Rockett, P.D.; Hunter, J.

    1993-01-01

    A prototype high-speed tape target transport is constructed for use in a high-repetition-rate laser plasma source. To reduce plasma debris, a 1000--5000-A-thick film of target material is supported by thin Mylar tape backing. Tape is transported to the laser focal volume at a maximum velocity of 356 cm/s, a rate sufficient to accommodate laser repetition rates of 1 kHz. The transport is fully vacuum compatible and can be retracted and then isolated from the laser plasma vacuum enclosure during tape reel replacement. The operating characteristics of the transport are described

  9. Pinning Mechanisms in YBCO Tapes

    CERN Document Server

    Spera, Marcello; Ballarino, Amalia

    2015-01-01

    In this thesis work, a study on flux pinning mechanisms of commercial YBCO tapes is presented. This study has been performed via critical current characterization using transport (via direct I-V curves) and magnetization (via a Vibrating Sample Magnetometer) measurements. The latter ones turned out to be better concerning the comprehension of the pinning landscape of the provided samples, as a wider range of magnetic fields and temperatures is available for those measurements in the setup I used. The comparison of the experimental data with existing theoretical models allowed me to draw a picture of the pinning mechanisms underlying in each sample, and they turned out to be quite different one another. Moreover, for high-performance research tapes, another interesting feature has been found: the counterplay between the self-field critical current and the in-field one. Very well engineered artificial pinning structures limit the self-field critical current density due to the hi...

  10. Evaluating Postural Control and Ankle Laxity Between Taping and High-Top Cleats in High School Football Players.

    Science.gov (United States)

    Pizac, Douglas A; Swanik, Charles B; Glutting, Joseph J; Kaminski, Thomas W

    2018-03-01

    Lateral ankle sprains are the most common injuries in high school sports. While ankle taping is a preferred method of external prophylactic support, its restrictive properties decline during exercise. The Under Armour ® Highlight cleat is marketed on the premise that it provides added support without the need for additional ankle taping. To determine if differences in ankle joint laxity and postural control exist between football players wearing the Under Armour ® Highlight cleat (Under Armour Inc, Baltimore, MD) as compared to a low/mid-top cleat with ankle tape. Crossover trial. Athletic training room and football practice field sideline. 32 interscholastic football players (15.8 ± 1.0 y; 178.9 ± 7.4 cm; 87.1 ± 21.4 kg). Ankle laxity was assessed using an instrumented ankle arthrometer (Blue Bay Research Inc, Milton, FL), while postural control testing was performed on the Tekscan MobileMat™ Balanced Error Scoring System (BESS; South Boston, MA). The 2 treatments included Under Armour ® Highlight cleats and a low/mid-top cleat with ankle tape applied to the nondominant ankle only. Measurements were taken before and immediately after practice. The independent variable was treatment (Highlight vs low/mid-top cleat with ankle tape). Dependent variables included ankle arthrometry measures of anterior displacement (mm), inversion/eversion rotation (deg), and the modified BESS error scores. A linear mixed-effects model was used for analysis. The low/mid-top cleat with tape condition had significantly higher inversion range-of-motion (ROM) and inversion/eversion rotation postexercise when compared to the Highlight cleat (P Under Armour ® Highlight cleat restricts ankle ROM following a training session better than the taped low/mid-top cleat. Further study is warranted to determine if this high-top style of football cleat can reduce the incidence of ankle sprains and how it might compare to spat taping.

  11. High rate of vaginal erosions associated with the mentor ObTape.

    Science.gov (United States)

    Yamada, Brian S; Govier, Fred E; Stefanovic, Ksenija B; Kobashi, Kathleen C

    2006-08-01

    The transobturator tape method is a newer surgical technique for the treatment of stress urinary incontinence. Limited data exist related to complications with this approach or the types of mesh products used. We report our experience with vaginal erosions associated with the Mentor ObTape and American Medical Systems Monarc transobturator slings. Beginning in December 2003 selected female patients with anatomic urinary incontinence were prospectively followed after placement of the Mentor ObTape. Beginning in January 2004 we also began using the American Medical Systems Monarc in similar patients. Patients were admitted overnight after surgery, discharged on oral antibiotics, and seen in the clinic at 6 weeks postoperatively. A total of 67 patients have undergone placement of the Mentor ObTape and 9 of those patients (13.4%) have had vaginal extrusions of the sling. Eight patients reported a history of persistent vaginal discharge. One patient presented initially to an outside facility with a left thigh abscess tracking to the left inguinal incision site. Each patient was taken back to the operating room for mesh removal. A total of 56 patients have undergone placement of the AMS Monarc and none have had any vaginal erosions. Our high rate of vaginal extrusion using the ObTape has led us to discontinue the use of this product in our institution. Continued followup of all of these patients will be of critical importance.

  12. Research and development efforts relative to superconducting materials. Final report. [Nb/sub 3/Sn tapes

    Energy Technology Data Exchange (ETDEWEB)

    Adam, E; Beishcher, P; Marancik, W; Lucariello, R; Young, M

    1976-04-01

    Three processes for the production of low-loss superconducting tapes of Nb/sub 3/Sn were investigated. They are the rolled-bronze process, the electron beam (EB) bronze deposition process, and the high-rate sputtering process. Shortly after the start of the investigation, effort on the last two processes was suspended because the process-development time that would be needed to arrive at a suitable transmission-line tape appeared most likely to be the shortest with the rolled-bronze process. Long lengths of Nb/sub 3/Sn tapes were prepared by the rolled-bronze process from extruded and rolled bronze-clad niobium billets. Tapes were stabilized by removing the bronze layer after reaction and then coating the exposed Nb/sub 3/Sn with high-purity copper by EB evaporation. Several meters of high quality Nb/sub 3/Sn tapes were produced by the rolled-bronze process. Even when the tapes were stabilized with copper, the losses were as low as 1.8 ..mu..W/cm/sup 2/ at 4.2 K and a surface current density of 500 rms A/cm. Despite early curtailment of the effort on the EB bronze-deposition process, short samples of Nb/sub 3/Sn tapes were produced.

  13. Quantitative analysis of the effects of strain-state on the microstructure and Jc of BSCCO tapes

    International Nuclear Information System (INIS)

    Blumenthal, W.R.; Zhu, Y.T.; Sebring, R.J.; Lowe, T.C.; Asaro, R.J.

    1996-01-01

    After considerable optimization efforts, conventional thermomechanical processing of long, high temperature superconductors has not produced critical current densities (J c ) adequate for most liquid nitrogen temperature applications. New approaches are needed to improve the J c of superconducting tape produced by co-deforming a ductile silver sheath containing the superconducting oxide using the powder-in-tube process. This study investigates improvements in J c generated by modifying the strain-state during rolling of silver-sheathed Bi 2 Sr 2 Ca 2 Cu 3 O 10+x (BSCCO-2223) tape using quantitative image analysis of the different phases. Pure compression and combined compression-shear loading was achieved by embedding BSCCO-2223 tapes at different locations within thick steel blocks. High hydrostatic compressive stress was imposed by confining the tape width. Tapes deformed with combined shear-compression exhibited measurably higher J c values than tapes subjected to pure compression, but their microstructures showed little difference in the amount of nonconducting (including porosity) phase content. However, constraining the tape width resulted in the most significant increase in J c which corresponded to a much lower porosity and nonconducting phase volume in the oxide near the tape edge

  14. Properties of hot pressed MgB2/Ti tapes

    International Nuclear Information System (INIS)

    Kovac, P.; Husek, I.; Melisek, T.; Fedor, J.; Cambel, V.; Morawski, A.; Kario, A.

    2009-01-01

    Hot axial and hot isostatic pressing was applied for single-core MgB 2 /Ti tapes. Differences in transport current density, n-exponents and critical current anisotropy are discussed and related to the grain connectivity influenced by pressing. The magnetic Hall probe scanning measurements allowed observing the isolated regions for axially hot pressed sample attributed to the longitudinally oriented cracks introduced by pressing. The highest current densities were measured for the tape subjected to hot isostatic pressing due to improved connectivity.

  15. Study of microstructure and superconducting properties of Nb3Al-tapes, obtained by heat treatment of three-layer and multilayer composites Nb/AlCu

    International Nuclear Information System (INIS)

    Korzhov, Valeriy P.

    2012-01-01

    The structure and superconductivity of three- and multilayer composite tapes of Nb/AlCu after high- temperature heating at 1750-1850 0 C for 1-3 seconds were investigated. Three-layer composites of Nb/AlCu/Nb with thickness of 50 microns were obtained by applying a vacuum rolling at 400-450 0 C and subsequent rolling at room temperature. Multilayer lengthy composites of Nb/AlCu obtained by extrusion with subsequent flattening by rolling of complex blank, collected in a special way. The effect of copper on the structure and properties of three-layer tapes was investigated. Copper increased the critical current of the superconductor. The critical current density in multilayered Nb 3 Al-tape reaches the value 8.10 4 A/cm 2 in magnetic field 14 T. The critical bending radius of the tape is 7 mm. Key words: multilayer composite tape, extrusion, rolling, superconducting Nb 3 Al-tape, high- temperature heat treatment, critical current density

  16. Bidirectional recording performance of a perpendicular evaporated Co-CoO tape

    Energy Technology Data Exchange (ETDEWEB)

    Motohashi, K. [Sony Corporation, 3-4-1 Sakuragi, Tagajo-shi, Miyagi 985-0842 (Japan)], E-mail: Kazunari.Motohashi@jp.sony.com; Ikeda, N.; Sato, T.; Shiga, D.; Ono, H.; Onodera, S. [Sony Corporation, 3-4-1 Sakuragi, Tagajo-shi, Miyagi 985-0842 (Japan)

    2008-11-15

    It is the first report on the recording performance of a perpendicular metal evaporated (ME) tape measured with a giant magnetoresistive head. To solve the application difficulty of oblique evaporated tape media to linear scan tape systems, a perpendicular evaporated Co-CoO tape was proposed instead. The prepared sample showed perpendicular anisotropy with coercivity of 107.3 kA/m, M{sub r}t of 3.9 mA and squareness of 0.25. Identical recording characteristics were obtained for both head-media moving directions, which enables the application of perpendicular evaporated Co-CoO tape to linear scan tape systems. The better carrier-to-noise ratio was also confirmed by comparison with a current advanced product of metal particulate tape, which can realize the higher recording density of linear scan tape systems using ME tape.

  17. Bidirectional recording performance of a perpendicular evaporated Co-CoO tape

    International Nuclear Information System (INIS)

    Motohashi, K.; Ikeda, N.; Sato, T.; Shiga, D.; Ono, H.; Onodera, S.

    2008-01-01

    It is the first report on the recording performance of a perpendicular metal evaporated (ME) tape measured with a giant magnetoresistive head. To solve the application difficulty of oblique evaporated tape media to linear scan tape systems, a perpendicular evaporated Co-CoO tape was proposed instead. The prepared sample showed perpendicular anisotropy with coercivity of 107.3 kA/m, M r t of 3.9 mA and squareness of 0.25. Identical recording characteristics were obtained for both head-media moving directions, which enables the application of perpendicular evaporated Co-CoO tape to linear scan tape systems. The better carrier-to-noise ratio was also confirmed by comparison with a current advanced product of metal particulate tape, which can realize the higher recording density of linear scan tape systems using ME tape

  18. Placement suitability criteria of composite tape for mould surface in automated tape placement

    Directory of Open Access Journals (Sweden)

    Zhang Peng

    2015-10-01

    Full Text Available Automated tape placement is an important automated process used for fabrication of large composite structures in aeronautical industry. The carbon fiber composite parts realized with this process tend to replace the aluminum parts produced by high-speed machining. It is difficult to determine the appropriate width of the composite tape in automated tape placement. Wrinkling will appear in the tape if it does not suit for the mould surface. Thus, this paper deals with establishing placement suitability criteria of the composite tape for the mould surface. With the assumptions for ideal mapping and by applying some principles and theorems of differential geometry, the centerline trajectory of the composite tape is identified to follow the geodesic. The placement suitability of the composite tape is examined on three different types of non-developable mould surfaces and four criteria are derived. The developed criteria have been used to test the deposition process over several mould surfaces and the appropriate width for each mould surface is obtained by referring to these criteria.

  19. Shielded high-T{sub c} (Bi, Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (Bi-2223) superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Lelovic, M.; Eror, N.G. [Department of Materials Science, University of Pittsburgh, Pittsburgh, PA (United States); Balachandran, U.; Prorok, B. [Energy Technology Division, Argonne National Laboratory, Argonne, IL (United States); Selvamanickam, V.; Haldar, P. [Intermagnetics General Corporations, Latham, NY (United States); Talvacchio, J.; Young, R. [Science and Technology Center, Northrop Grumman, Pittsburgh, PA (United States)

    1998-11-01

    A new composite tape was fabricated in which the primary function of the central Ag-sheathed (Bi, Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (Bi-2223) filaments was to conduct transport current. A YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (Y-123) thin film was deposited on the top of the Ag-sheathed Bi-2223 tape to shield the applied magnetic field and to protect the central Bi-2223 filaments. The critical current densities of the Y-123-coated, Ag-sheathed Bi-2223 tapes were better than those of an uncoated tape. However, the Y-123 thin film exhibited T{sub c} approx.= 72 K and a broad transition region that shifted the effect to lower temperatures. Furthermore, pole figure measurements showed widely spread a,b planes along the rolling direction, indicating high-angle grain boundaries that diminished the magnitude of the effect. Microstructural observations showed platelike grains of Y-123 with fine growth ledges in the thin film that was heat treated, in contrast with the microstructure of an as-coated thin film that showed large twinned grains. From the processing point of view, the results showed that heat treating Y-123 thin film according to the Bi-2223 tape schedule was compatible with and beneficial for Y-123. These preliminary results may provide a basis for further improvements in processing of long-length Bi-2223 tapes for high-field applications. (author)

  20. Uranium doping and neutron irradiation of Bi-2223 superconduction tapes for improved critical current density

    International Nuclear Information System (INIS)

    Moss, S.D.; Wang, W.G.; Dou, S.X.; Weinstein, R.

    1998-01-01

    It is demonstrated that a combination of neutron irradiation with uranium doping introduce fission tracks through a Bi-2223 tape which act as effective pinning centres, leading to a substantial increase in critical current. Preliminary data suggests that the combination of uranium doping and neutron irradiation produces improved flux pinning in Bi-2223 tapes over neutron irradiation alone. Before irradiation, SEM, DTA and XRD analyses were performed on the tapes. Both before and after irradiation the trapped maximum magnetic flux was measured at 77K. Before neutron irradiation, uranium doping has no effect on critical current. Preliminary SEM data suggested that the uranium is homogeneously distributed throughout the oxide core of the tape. The presence of 2212 and other secondary phases in the doped tapes suggest further refinement of the sintering procedure is necessary. (authors)

  1. Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

    Science.gov (United States)

    Prien-Larsen, Jens Christian; Prien-Larsen, Thomas; Cieslak, Lars; Dessau, Ram B

    2016-07-01

    Although there is clear consensus on the use of monofilament polypropylene tapes for treating stress urinary incontinence (SUI), tapes differ in weight, stiffness, and elasticity. In this study, we compared outcomes of two tape types: high-stiffness Intramesh SOFT L.I.F.T versus low-stiffness Intramesh L.I.F.T. tape. Our null hypothesis was that in terms of performance, SOFT tape equaled L.I.F.T. tape. Six hundred and sixty women underwent prospective transvaginal tape (TVT) surgery for SUI: 210 had the SOFT tape placed and 450 the L.I.F.T. tape. Follow-ups were scheduled at 3 and 12 months. Objective cure at 3-months' follow-up was 87 % in the SOFT group vs 94 % in the L.I.F.T. group (p = 0.003) and at 12 months 86 vs 96 % (p = 0.0004), respectively. Subjective outcomes were equal. For SOFT tape, the objective failure rate at 3 months was especially pronounced in women older than 70 years: 31 vs 10 % (p = 0.008), and subjective failure was 24 vs 7 % (p = 0.01). At 12 months, objective failure for the SOFT tape was significantly higher in both age groups compared with L.I.F.T. [odds ratio (OR) 2.17]. Multivariate analysis showed that body mass index (BMI) ≥30 (OR 2.41), mixed incontinence (MUI) (OR 2.24), use of SOFT tape (OR 2.17), and age ≥ 70 years are significant independent risk factors for surgical failure. Outcomes with SOFT tape are significantly inferior than with L.I.F.T. tape, especially among elderly women. Therefore, the two variants of monofilament polypropylene tape are not interchangeable.

  2. Critical current of high Tc superconducting Bi223/Ag tapes

    NARCIS (Netherlands)

    Huang, Y.; ten Haken, Bernard; ten Kate, Herman H.J.

    1998-01-01

    The magnetic field dependence of the critical current of various high Tc superconducting Bi2223/Ag tapes indicates that the transport current is carried through two paths: one is through weakly-linked grain boundaries (Josephson junctions); another is through well-connected grains. The critical

  3. Electromagnetic Properties of (Gd, Y)Ba2Cu3Ox Superconducting Tapes With High Levels of Zr Addition

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y; Yao, Y; Chen, Y; Khatri, ND; Liu, J; Galtsyan, E; Lei, C; Selvamanickam, V

    2013-06-01

    The dependence of the critical current density (J(c)) on the orientation of applied magnetic fields was studied in Zr-doped (Gd, Y)Ba2Cu3Ox tapes fabricated by metal organic chemical vapor deposition. The in-field performance of J(c) of (Gd, Y)Ba2Cu3Ox tapes with Zr-doping levels of 7.5-30 at.% was investigated up to 5 T over a temperature range of 40-77 K. The highest critical currents (I-c) at H parallel to c and the highest values of minimum Ic in angular dependence measurements were achieved in the tapes with 20% Zr doping over a broad range of temperature and magnetic field conditions measured. The electromagnetic properties have been related to the changes in BaZrO3 content and microstructure.

  4. Anisotropy of the critical current in MgB2 tapes made of high energy milled precursor powder

    DEFF Research Database (Denmark)

    Hässler, W.; Kovac, P.; Eisterer, M.

    2010-01-01

    For applications of MgB2 wires or tapes, high critical currents in high magnetic fields are essential. By using tapes in superconducting coils the anisotropic behaviour of the critical current, i.e. the dependence on the direction of the external field in relation to the tape surface, has to be t...

  5. Paper Punch Tape

    CERN Multimedia

    Physicists coded and recorded their programs through series of holes on punch paper tape or on punched cards. It was popular in the 1970s due to its high throughput speed and low cost, paper tape was one of the original data storage methods for computers. Information was encoded in the distinct pattern of holes punched in the paper; the paper itself was oiled to facilitate being run through the reading mechanism and to prevent tears due to brittleness. Though the paper was cheap, it had low storage capacity (only a few dozen kilobytes per roll) and the machinery involved in punching the holes was quite expensive. Higher capacity alternatives, such as magnetic tape, has get developped.

  6. Enhancement in transport critical current density of ex situ PIT Ag/(Ba, K)Fe2As2 tapes achieved by applying a combined process of flat rolling and uniaxial pressing

    Science.gov (United States)

    Togano, Kazumasa; Gao, Zhaoshun; Matsumoto, Akiyoshi; Kumakura, Hiroaki

    2013-11-01

    We report that the transport critical current density Jc of ex situ powder-in-tube (PIT) processed (Ba, K)Fe2As2 (Ba-122) tapes can be significantly enhanced by applying uniaxial cold pressing at the final stage of deformation. The tapes were prepared by packing high quality precursor powder into a Ag tube, cycles of rolling and intermediate annealing, and pressing followed by the final heat treatment for sintering. The Jc values in applied magnetic fields were increased by almost one order of magnitude compared to the tapes processed without pressing, exceeding 104 A cm-2 at 4.2 K. We achieved the highest Jc (at 4.2 K and 10 T) of 2.1×104 A cm-2 among PIT-processed Fe-based wires and tapes reported so far. The Jc-H curves measured at higher temperatures maintain small field dependence up to around 20 K, suggesting that these tapes are promising for applications at higher temperatures as well as at liquid helium temperature. The microstructure investigations reveal that there are two possible causes of the large Jc enhancement by pressing: one is densification and the other is the change of crack structure. Optimization of processing parameters such as the reduction ratio of rolling and pressing is expected to yield further Jc enhancement.

  7. The fabrication and high temperature stability of biaxially textured Ni tape by ion beam structure modification method

    International Nuclear Information System (INIS)

    Wu, K.; Wang, S.S.; Meng, J.; Han, Z.

    2004-01-01

    For the conventional rolling assisted biaxially textured metallic substrate (RABiTS) process, a large degree of cold rolling deformation and a subsequent high temperature annealing procedure are required to obtain adequately biaxially textured Ni tape. Recently, we have reported a newly developed process, named as ion beam structure modification (ISM), for fabricating biaxially textured Ni tape by use of low energy argon ion beam bombardment. In this paper, the biaxial texture of ISM processed Ni tape and its thermal stability at high temperatures are investigated. Results show that Ni tape processed under optimum ISM conditions, the (2 0 0) rocking curve FWHM is less than 5.7 deg. , and the (1 1 1) phi-scan FWHM is less than 7.5 deg. . High temperature annealing does not impair the biaxial-texture already developed in ISM processed Ni foils, although ISMs should not be regarded as a complete equilibrium process

  8. Influence of self-field on the critical current of Bi-2223/Ag tapes

    International Nuclear Information System (INIS)

    Lehtonen, Jorma; Korpela, Aki; Nah, Wansoo; Kang, Joonsun; Kovac, Pavol; Melisek, Tibor

    2004-01-01

    The knowledge of critical current density in a superconducting wire is essential in order to compute AC losses. In HTS tapes the critical current density is difficult to estimate from the measured critical current because self-field tends to reduce the current carrying capacity. In this paper the critical current is measured with a single sample and with two similar samples connected in antiparallel in order to compensate the self-field. Both types of measurement are simulated with finite element method. The simulations help to understand the relation between the measured critical current and material properties. The results suggest that in a high quality tape the self-field effect reduced the measured critical current ∼25% if compared to the real critical current at the zero external field

  9. Progress in Jc and magnetic field performance of Bi-2223/Ag composite tapes

    International Nuclear Information System (INIS)

    Savvides, N.; Katsaros, A.; Reilly, D.; Thorley, A.; Herrmann, J.

    1998-01-01

    Full text: The application of high-temperature superconductors to electric power systems is actively pursued by several commercial teams around the world. A promising candidate is the Bi-2223/Ag composite superconductor. For large scale commercial applications the conductor must meet certain engineering specifications including high current capacity in the presence of a self-generated magnetic field ranging from a few hundred mT in transmission cables to 1-2 T in transformers and current limiters, and to much higher fields in the case of superconducting coils for energy storage and magnets. In the last two years, a commercial consortium consisting of Metal Manufactures Ltd, University of Wollongong and CSIRO has focused on the development of Bi-2223/Ag composite tape suitable for use in electric power applications. The powder-in-tube process is used to produce conventional single filament and multifilament tapes and twisted conductors. An appropriate measure of 'process capability' is routine running of the process and evaluation of tape performance. In this paper we report on the electrical properties of Bi-2223/Ag composite tapes produced as part of the long-length product development. The transport critical current density of tapes is measured in magnetic fields up to 9 T (H parallel and H perpendicular tape-plane) and as a function of temperature (4 - 80 K). Transport ac losses are determined at 77 K and 60 Hz, and the bend strain performance is determined at 77 K for strains up to 1.5 %

  10. Development of advanced NI alloy substrates with high percentage of cube texture for biaxially oriented YBCO coated tapes

    International Nuclear Information System (INIS)

    HongLi Suo; Yue Zhao; MangMang Gao; Min Liu; YongHua Zhu; PeiKuo Gao; JianHong Wang; Lin Ma; RuiFen Fan; Yuan Ji; MeiLing Zhou

    2009-01-01

    The improvement of mechanical and magnetic properties of textured NiW alloy tapes is considered as a main challenge for RABiTS substrates in coated conductors. The present paper summaries the successful development of several textured NiW substrate tapes with high W contents as well as advanced NiW composite substrates with high strength and reduced magnetization in our previous works. The fabrication process of these tapes and their characterizations are presented in detail. The results on the texture quality and mechanical properties as well as on the magnetic behaviour of these tapes are promising in view of the future application in coated conductor and constitute an alternative to the well known Ni5W alloy substrates. (au)

  11. Tape transport mechanism

    International Nuclear Information System (INIS)

    Groh, E.F.; McDowell, W.; Modjeski, N.S.; Keefe, D.J.; Groer, P.

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer

  12. Recovery time of high temperature superconducting tapes exposed in liquid nitrogen

    International Nuclear Information System (INIS)

    Sheng, Jie; Zeng, Weina; Yao, Zhihao; Zhao, Anfeng; Hu, Daoyu; Hong, Zhiyong

    2016-01-01

    Highlights: • A novel method based on a sequence of AC pulses is presented. • Liquid nitrogen temperature is used as criterion to judge whether the sample has recovered. • Recovery time of some tape doesn't increase with the amplitude of fault current. • This phenomenon is caused by boiling heat transfer process of liquid nitrogen. • This phenomenon can be used in optimizing both the limiting rate and reclosing system. - Abstract: The recovery time is a crucial parameter to high temperature superconducting tapes, especially in power applications. The cooperation between the reclosing device and the superconducting facilities mostly relies on the recovery time of the superconducting tapes. In this paper, a novel method is presented to measure the recovery time of several different superconducting samples. In this method criterion used to judge whether the sample has recovered is the liquid nitrogen temperature, instead of the critical temperature. An interesting phenomenon is observed during the testing of superconducting samples exposed in the liquid nitrogen. Theoretical explanations of this phenomenon are presented from the aspect of heat transfer. Optimization strategy of recovery characteristics based on this phenomenon is also briefly discussed.

  13. The neutron beam users tape management system

    International Nuclear Information System (INIS)

    Lyall, B.; Johnson, M.W.

    1977-02-01

    Systems are described for dealing with data collected at the High Flux Reactor, Institut Laue-Langevin, Grenoble and brought on magnetic tape to the Neutron Beam Research Unit at the Rutherford Laboratory. The first system, named GNAT, was designed to archive the incoming 800 bpi tapes onto 6250 bpi tapes (to enable them to return to the ILL). The archiving program, besides choosing the archive tapes, keeping a record of the data sets archived, and writing the archive tape, should be able to cope with incoming tapes whose formats are somewhat different from the standard IBM format. The second system, named FONT, was designed to maintain a record of all the tapes in the NBRU's possession, their whereabouts and what data, if any, are on them. (U.K.)

  14. A jelly-roll process for high temperature superconducting tapes and wires

    International Nuclear Information System (INIS)

    Tsuei, C.C.; Chi, C.C.; Frey, T.; Mitzi, D.B.; Kazyaka, T.; Haugan, T.; Ye, J.; Patel, S.; Shaw, D.T.; Wu, M.K.

    1992-01-01

    As an alternative to the powder-in-tube method, a new technique called the jelly-roll process is proposed for making high-T c superconducting tapes and wires. A normal-metal sheet coated with high-T c cuprate is configured in a jelly-roll fashion and cold worked into tapes or wires made of alternating cuprate superconductor and normal metal layers. The feasibility of this new process is demonstrated for both the YBa 2 Cu 3 O 7 /Ag and Bi 2 Sr 2 CaCu 2 O 8 /Ag composite systems. The role of reduction in the cross-sectional area by cold-rolling, heat treatment and oxygenation in optimizing T c and J c has been studied. Preliminary results indicate that partialmelt texturing, in the Bi 2 Sr 2 CaCu 2 O 8 /Ag system, results in a relatively field independent J c (H c (H = 0) ∝5 X 10 4 A cm -2 at 4.2 K

  15. Ubiquitous Graphene Electronics on Scotch Tape

    Science.gov (United States)

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-07-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm-2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V-1 s-1 the transistors still showed high mobility of 1254 (±478) cm2 V-1 s-1 even after they were crumpled.

  16. Critical current density, irreversibility line, and flux creep activation energy in silver-sheathed Bi2Sr2Ca2Cu3Ox superconducting tapes

    International Nuclear Information System (INIS)

    Shi, D.; Wang, Z.; Sengupta, S.; Smith, M.; Goodrich, L.F.; Dou, S.X.; Liu, H.K.; Guo, Y.C.

    1992-08-01

    Transport data, magnetic hysteresis and flux creep activation energy experimental results are presented for silver-sheathed high-T c Bi 2 Sr 2 Ca 2 Cu 3 O x superconducting tapes. The 110 K superconducting phase was formed by lead doping in a Bi-Sr-Ca-Cu-0 system. The transport critical current density was measured at 4.0 K to be 0.7 x 10 5 A/cm 2 (the corresponding critical current is 74 A) at zero field and 1.6 x 10 4 A/cm 2 at 12 T for H parallel ab. Excellent grain alignment in the a-b plane was achieved by a short-melting method, which considerably improved the critical current density and irreversibility line. Flux creep activation energy as a function of current is obtained based on the magnetic relaxation measurements

  17. Tape dig selv!

    DEFF Research Database (Denmark)

    Andersen, Bente Annie Sørine; Neergaard, Christian; Seest, Kristian

    Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives......Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives...

  18. Reel-to-reel substrate tape polishing system

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  19. Magnetic field profiles of NbTi tapes

    International Nuclear Information System (INIS)

    Migliori, A.; Taylor, R.D.; Bartlett, R.D.

    1976-01-01

    Magnetic field profile measurements were performed on stabilized NbTi tapes in zero applied field carrying large transport current densities. Field profile data were taken on large diameter superconducting sample loops at temperatures between 2 0 K and T/sub c/ (about 9.2 0 K) and several persistent currents up to I/sub c/(T), the maximum. The field profiles scaled with current, independent of temperature, at temperatures below 8.5 0 K and were well described by an elliptical shell approximation which left a current-free, field-free central region. Critical state models applied to this self-field situation proved inadequate. Complex profiles produced by trapped flux in the tape loop were described quantitatively by assuming concentric elliptical shells each with a different current density. The maximum current which could be persisted in the loop at each temperature was linear from 4 to 8.5 K. The effective resistance of the superconducting loop including its joint was less than 10 -13 ohms

  20. Critical current density above 15 MA cm−2 at 30 K, 3 T in 2.2 μm thick heavily-doped (Gd,Y)Ba2Cu3Ox superconductor tapes

    International Nuclear Information System (INIS)

    Selvamanickam, V; Gharahcheshmeh, M Heydari; Xu, A; Zhang, Y; Galstyan, E

    2015-01-01

    A critical current (I c ) value of 3963 A/12 mm, corresponding to a critical current density (J c ) of 15 MA cm −2 has been achieved at 30 K, 3 T in the orientation of field parallel to the c-axis (B||c) in 2.2 μm thick film (Gd,Y)BaCuO tapes with 20 mol% Zr addition made by metal organic chemical vapor deposition. This J c level is more than a factor of four higher than the J c values of 7.5 mol% Zr-added tapes, which are an industry benchmark. The critical current values in a magnetic field of 3 T parallel to the c-axis in the 2.2 μm thick, 20 mol% Zr-added tape reached 2833 A/12 mm (10.1 MA cm −2 ), 1881 A/12 mm (7.1 MA cm −2 ) and 805 A/12 mm (3.1 MA cm −2 ) at 40 K, 50 K and 65 K respectively. Such high critical current values were possible because of maintaining a strong alignment of BaZrO 3 nanocolumns along the c-axis over the entire film thickness. (fast track communication)

  1. HTS Nested magnet wound with 12 mm GdBCO tape and 4.4 mm YBCO tape

    International Nuclear Information System (INIS)

    Kang, Myung Hun; Ku, Myung Hwan; Cha, Guee Soo; Lim, Hyoung Woo

    2015-01-01

    The properties of High Temperature Superconducting (HTS) tapes are progressing, as HTS tapes evolve from 1st generation to 2nd generation. This paper presents design and construction of a 2nd generation HTS magnet consisting of two nested GdBCO and YBCO pancake coils. Two HTS tapes of different widths were used to wind the HTS nested magnet. Considering that a higher magnetic field is applied to the inner magnet than to the outer magnet, 12 mm GdBCO tape was used for winding the inner magnet, which consisted of four single pancake windings. Eight double pancake windings wound with 4.4 mm YBCO tapes were used for the outer magnet. The test results show that the central magnetic field of the HTS nested magnet was 920 mT. The measured critical currents of the inner and outer magnet at 77K were 80.8 A and 32.6 A, respectively

  2. The effect of Ag doping on superconducting properties of the Bi-Pb-Sr-Ca-Cu-O tape fabricated by an Ag sheath

    International Nuclear Information System (INIS)

    Oota, A.; Horio, T.; Ohba, K.; Iwasaki, K.

    1992-01-01

    The powder-in-tube method using an Ag sheath is applied to achieve high current capacity in the tapes of Bi-Pb-Sr-Ca-Cu-O (BPSCCO) with the high-T c phase (T c =110 K), by a combination process of cold working and sintering. Two kinds of the BPSCCO powder with and without Ag doping are used as the materials for tape fabrication. The morphology, structure, and critical current density J c are investigated on the tapes by x-ray diffraction, differential thermal analysis, scanning electron microscope, magnetic susceptibility, and I-V curves. The optimum sintering conditions to obtain a maximum in the value of J c at 77 K and 0 T are presented in the Ag-doped tapes and the nondoped ones. An improvement in the J c vs B properties up to 1 T at 77 K is presented in the BPSCCO tape by Ag doping. The Ag doping causes neither change in the value of T c (=110 K) nor decomposition of the high-T c phase

  3. Analysis of trace element compositions in adhesive cloth tapes using high-energy x-ray fluorescence spectrometer with three-dimensional polarization optics for forensic discrimination

    International Nuclear Information System (INIS)

    Goto, Akiko; Hokura, Akiko; Nakai, Izumi

    2008-01-01

    The forensic discrimination of adhesive cloth tapes often used in crimes was developed using a high-energy energy-dispersive X-ray fluorescence spectrometer with 3-dimensional polarization optics. The best measurement condition for discrimination of the tape was as follows: secondary targets, Rh and Al 2 O 3 ; measurement time, 300 s for Rh and 600 s for Al 2 O 3 ; 14 elements (Ca, Ti, Cr, Mn, Fe, Ni, Zn, Sr, Zr, Nb, Mo, Sb, Ba and Pb) were used for discrimination. It is found that the combined information of yarn density and the XRF peak intensity of the 14 elements successfully discriminated 29 out of 31 samples, of which 2 probably had the same origin. This technique is useful for forensic analysis, because it is nondestructive, rapid and easy. Therefore, it can be applied to actual forensic identification. (author)

  4. A jelly-roll process for high temperature superconducting tapes and wires

    Energy Technology Data Exchange (ETDEWEB)

    Tsuei, C C; Chi, C C; Frey, T; Mitzi, D B; Kazyaka, T [IBM Thomas J. Watson Research Center, Yorktown Heights, NY (United States); Haugan, T; Ye, J; Patel, S; Shaw, D T [New York State Inst. on Superconductivity, SUNY, Buffalo, Amherst, NY (United States); Wu, M K [Dept. of Physics, National Tsing Hua Univ., Hsinchu (Taiwan)

    1992-07-01

    As an alternative to the powder-in-tube method, a new technique called the jelly-roll process is proposed for making high-T[sub c] superconducting tapes and wires. A normal-metal sheet coated with high-T[sub c] cuprate is configured in a jelly-roll fashion and cold worked into tapes or wires made of alternating cuprate superconductor and normal metal layers. The feasibility of this new process is demonstrated for both the YBa[sub 2]Cu[sub 3]O[sub 7]/Ag and Bi[sub 2]Sr[sub 2]CaCu[sub 2]O[sub 8]/Ag composite systems. The role of reduction in the cross-sectional area by cold-rolling, heat treatment and oxygenation in optimizing T[sub c] and J[sub c] has been studied. Preliminary results indicate that partialmelt texturing, in the Bi[sub 2]Sr[sub 2]CaCu[sub 2]O[sub 8]/Ag system, results in a relatively field independent J[sub c] (H< or approx.7T) with J[sub c](H = 0) [proportional to]5 X 10[sup 4] A cm[sup -2] at 4.2 K.

  5. Levitation characteristics of HTS tape stacks

    Energy Technology Data Exchange (ETDEWEB)

    Pokrovskiy, S. V.; Ermolaev, Y. S.; Rudnev, I. A. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2015-03-15

    Due to the considerable development of the technology of second generation high-temperature superconductors and a significant improvement in their mechanical and transport properties in the last few years it is possible to use HTS tapes in the magnetic levitation systems. The advantages of tapes on a metal substrate as compared with bulk YBCO material primarily in the strength, and the possibility of optimizing the convenience of manufacturing elements of levitation systems. In the present report presents the results of the magnetic levitation force measurements between the stack of HTS tapes containing of tapes and NdFeB permanent magnet in the FC and ZFC regimes. It was found a non- linear dependence of the levitation force from the height of the array of stack in both modes: linear growth at small thickness gives way to flattening and constant at large number of tapes in the stack. Established that the levitation force of stacks comparable to that of bulk samples. The numerical calculations using finite element method showed that without the screening of the applied field the levitation force of the bulk superconductor and the layered superconductor stack with a critical current of tapes increased by the filling factor is exactly the same, and taking into account the screening force slightly different.

  6. Transmission electron microscopy investigation of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Andersen, L.G.; Bals, S.; Tendeloo, G. Van

    2001-01-01

    during the tape processing, (3) a study of the grain boundaries on an atomic scale, including intergrowth investigations. Tapes with different process parameters have been compared with respect to the microstructure. A fully processed tape has on the average 50% thicker Bi-2223 grains than a tape after......The microstructure of (Bi,Pb)(2)Sr2Ca2CuOx (Bi-2223) tapes has been investigated by means of transmission electron microscopy (TEM) and high-resolution TEM. The emphasis has been placed on: (1) an examination of the grain morphology and size, (2) grain and colony boundary angles, which are formed...

  7. Development and evolution of biaxial texture of rolled nickel tapes by ion beam bombardment for high Tc coated conductors

    International Nuclear Information System (INIS)

    Wang, S.S.; Wu, K.; Shi, K.; Liu, Q.; Han, Z.

    2004-01-01

    High quality YBa 2 Cu 3 O 7-x films on metallic substrates with high critical current densities well over 10 6 A/cm 2 can be prepared by the rolling assisted biaxially textured substrates (RABiTS) method. Nickel or its alloys have been used as biaxially textured substrates formed through a specific rolling and high temperature annealing procedures. In this paper, we report a newly developed process for developing biaxial texture in rolled Ni tape by argon ion beam bombardment. It is named the ion-beam structure modification (ISM) process. In the ISM processed Ni foils, X-ray diffraction ω scans showed the full width-half maximum (FWHM) value of the (2 0 0) peak was 5.7 deg. . And the electron back scattering diffraction (EBSP) analysis based on scanning electron microscopy showed good {1 0 0} cubic orientation and the mean grain size was determined as about 25 μm. The texture evolution of rolled Ni foils during ISM process is reported also. For ISM process, local temperature elevation and distribution arises from the ion bombardment, coupled with anisotropic incident ion penetration and propagation as a result of channeling effects in the metal lattice, are expected to play the major roles in the development of grain reorientation in the Ni foil. Due to the simplicity and efficiency of the ISM process, the technique shows a great promise for application in the industrial scale production of long-lengths of superconductor tapes

  8. Bi axially textured YBCO coated tape prepared using dynamic magnetic grain alignment

    International Nuclear Information System (INIS)

    Genoud, Jean-Yves; Quinton, William

    1999-01-01

    A new magnetic grain alignment technique has been applied to produce bi axially aligned YBCO coated tapes. A bi axially aligned dispersion of orthorhombic Y 2 Ba 4 Cu 7 O 15 (Y-247) powder was settled on un textured silver substrates. The Y-247 tapes were then melt processed to achieve high critical current YBa 2 Cu 3 O 7 (Y-123) tapes with CuO as a secondary phase. The biaxial alignment is preserved after the densification process and a clear enhancement of J c relative to identically prepared un textured or uniaxially textured samples is obtained. Critical current densities of up to 5000 A cm -2 at 77 K in self-field and 1500 A cm -2 in 0.5 T magnetic field at 65 K were obtained in films from 20 to 40 μm thick. Problems were experienced in achieving fully densified thick films while retaining biaxial texture. The initial grain size distribution was found to have a major influence on the final microstructure. Provided significant improvements in J c can be obtained this method offers an alternative to coated tape processes based on epitaxial growth which has the advantage that it does not require textured substrates. The biaxial alignment technique described here intrinsically acts on the bulk material rather than at surfaces. This offers the possibility of texturing without thickness limitations. (author)

  9. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Chihaya, E-mail: chihaya.kurihara@jp.fujikura.com [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka [Kyushu University, 744 Motooka, Nishi-Ku, Fukuoka 819-0395 (Japan)

    2016-11-15

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I{sub c} measurement, we found that our new multi-filamentary tape could provide almost equal I{sub c} compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  10. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    International Nuclear Information System (INIS)

    Kurihara, Chihaya; Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro; Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka

    2016-01-01

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I_c measurement, we found that our new multi-filamentary tape could provide almost equal I_c compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  11. Enhancing the low-level tape layer of CERN Tape Archive software

    CERN Document Server

    AUTHOR|(CDS)2160814; Ruse, Laura Cristina; Vasilescu, Laura

    CERN manages the largest scientific data archive in the HEP domain. The archive currently holds over 180 Petabytes, with forecasts of up to 100PB of new data added per year. Considering this numbers, the most cost-effective solution for storage in terms of capacity and maintenance is represented by magnetic tapes. The drawback of this solution is the access time which can raise to several minutes for a series of files. In an environment where very large volumes of physics data are being traded from tape to disk and vice versa, this issue becomes a serious performance bottleneck. This thesis introduces two low-level tape access optimizations: first, adding support for the Recommended Access Order (RAO), a mechanism offered by the tape hardware infrastructure to compute the file order corresponding to the minimum access time. We will present our solution for including RAO in the file retrieval operations in CERN tape archive software in order to benefit from the reduced reading time. The second optimization ...

  12. Development of Powder-in-Tube Processed Iron Pnictide Wires and Tapes

    KAUST Repository

    Ma, Yanwei

    2011-06-01

    The development of PIT fabrication process of iron pnictide superconducting wires and tapes has been reviewed. Silver was found to be the best sheath material, since no reaction layer was observed between the silver sheath and the superconducting core. The grain connectivity of iron pnictide wires and tapes has been markedly improved by employing Ag or Pb as dopants. At present, critical current densities in excess of 3750 A /cm 2 (I c = 37.5 A) at 4.2 K have been achieved in Ag-sheathed SrKFeAs wires prepared with the above techniques, which is the highest value obtained in iron-based wires and tapes so far. Moreover, Ag-sheathed Sm-1111 superconducting tapes were successfully prepared by PIT method at temperatures as low as ̃ 900 °C, instead of commonly used temperatures of ̃ 1200 °C. These results demonstrate the feasibility of producing superconducting pnictide composite wires, even grain boundary properties require much more attention. © 2010 IEEE.

  13. Strategic flat rolling of Ag/BSCCO-2223 tapes

    DEFF Research Database (Denmark)

    Nielsen, Morten Storgård; Bech, Jakob Ilsted; Eriksen, Morten

    2002-01-01

    In the process of single-step flat rolling of multifilament Ag/BSCCO-2223 wire to tape previous work has shown the optimum strategy giving maximum critical current density to be it balance between the length and width strain, so they are of equal size i.e. so, that the logarithmic strain ratio, L...

  14. Texture gradients in Fe-sheathed ex situ produced MgB2 tapes

    International Nuclear Information System (INIS)

    Lezza, P; Gladyshevskii, R; Abaecherli, V; Fluekiger, R

    2006-01-01

    Superconducting Fe-sheathed MgB 2 monofilamentary tapes have been fabricated by the powder-in-tube technique, varying the particle size of the starting MgB 2 powder and applying either cold or hot rolling during the last deformation process. Measurements of the critical current density J c with the magnetic field applied parallel or perpendicular to the tape surface revealed a pronounced anisotropy for the cold rolled tapes, which was found to increase with increasing particle size and magnetic field strength. The microstructural origin of the J c anisotropy was confirmed by means of x-ray diffraction performed on the filaments after mechanical removal of the sheath. The local texture was studied in a series of diffraction patterns collected at different distances from the filament centre, removing each time some 25 μm of the filament thickness. In the cold rolled tapes, the average orientation of the MgB 2 grains was found to approach a preferred orientation with the crystallographic c-axis perpendicular to the tape surface, near the interface with the sheath; however, the misalignment angle increased towards the centre of the tape. In the hot rolled tapes, for which no J c anisotropy was observed, the grains were found to be approximately randomly oriented. Roughness measurements performed on the side of the Fe sheath in contact with the MgB 2 filament are in agreement with the difference in texture observed for cold and hot rolled tapes

  15. The Imation 9840 Tape Cartridge

    CERN Multimedia

    It’s a 20 GB uncompressed center-load cartridge used in StorageTek T9840 tape drives. The tape is a Metal Particle (MP) tape suitable for use on all Oracle/Sun/StorageTek 9840 A, B, C and D drives. The 9840 tape has an archival life of 15-30 years.

  16. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T.

    2010-10-15

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  17. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T; Nguyen, H. D.; Takehara, K.; Etoh, T. G.

    2010-01-01

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  18. Applied rolling and sensitivity of Bi(2223)/Ag tapes on Ic degradation by mechanical stress

    International Nuclear Information System (INIS)

    Kovac, P.; Bukva, P.; Husek, I.; Richens, P.E.; Jones, H.

    1999-01-01

    An experimental study of multicore Bi(2223)/Ag tapes, roll-sintered by different methods and subjected to bending and tension stresses has been performed. The tapes, of various technological histories, were bent and tensioned and subsequently the transport current was measured at each stressed state. Comparison of I c degradation curves shows that applied rolling may influence the sensitivity of Bi-2223 filaments against the mechanical stress. The existence of transverse microcracks caused by intermediate rolling leads to a higher sensitivity of the tape to bending. A lowering of critical current degradation was observed for two-axially rolled tapes having a higher filament density and better homogeneity prior to sintering treatment. (author)

  19. Development and Characterization of P-doped Ba-122 Superconducting Tapes

    KAUST Repository

    Contarino, D.

    2016-11-29

    Among the recently discovered Fe-based superconducting compounds, the Ba-122 phase has proved to be the more attracting for the development of powder in tube (PIT) processed conductors. In fact, after some years of development, critical current densities (Jc) of about 105 A/cm2 at 4.2 K and magnetic fields up to 10 T have been obtained in (Ba0.6K0.4)Fe2As 2, PIT wires and tapes. To develop a safe upscaling method, the synthesis of the powders is a crucial point. In order to avoid the use of highly reactive K we have developed BaFe2(P1-xAsx)2 PIT tapes. This compound has proved to be very stable and in form of crystals and thin films exhibits excellent critical current: We succeeded in manufacturing PIT tapes with this phase with Jc values of about 103 A/cm2 at 4.2 K in self-field. Detailed microstructural and chemical investigations of the samples have been performed by high-resolution TEM, scanning TEM, and electron energy loss spectrometry analysis. A deformation network inside the grains that can induce strong pinning has been observed. However, chemical inhomogeneities at the grain boundaries are also present, which limit the transport current.

  20. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15?h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ank...

  1. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    Science.gov (United States)

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  2. StorageTek RedWood SD-3 tape drive

    CERN Multimedia

    1995-01-01

    A helical scan recording drive, with a high-speed rotating head sweeping across the tape every few micrometers. Based on a professional video recording system, modified to be suitable for digital data recording. These are commonly used with large computer systems, typically in conjunction with a robotic tape library.

  3. Limits to the critical transport current in superconducting (Bi,Pb)2Sr2Ca2Cu3O10 silver-sheathed tapes: The railway-switch model

    International Nuclear Information System (INIS)

    Hensel, B.; Grasso, G.; Fluekiger, R.

    1995-01-01

    We have proposed the ''railway-switch'' model to describe the superconducting transport current in (Bi,Pb) 2 Sr 2 Ca 2 Cu 3 O 10 silver-sheathed tapes. The model assumes that in the textured polycrystalline filament the frequent small-angle c-axis tilt grain boundaries (''railway switches'') constitute strong links for the supercurrent. With the objective to identify the mechanisms that limit the critical-current density in the tapes we present measurements of the transport critical current normal to the tape plane and of the current-transfer length along the tape axis. From I-V curves we obtain the longitudinal critical-current distribution and compare it to the thickness variation of the filament. The experiments have been performed on monofilamentary powder-in-tube samples prepared in long lengths by rolling as the only tape-forming process. For all investigated samples the critical-current density at T=77 K in self-field was in the range j c =20--30 kA/cm 2 . We conclude that the dominant limitation for the transport critical current in the tapes is imposed by the low intragrain critical-current density j c c along the c axis (as compared to the in-plane critical-current density j c ab ) and by the even lower critical-current density j c t across twist boundaries or intergrowths. Possibilities for an improvement of the performance of the (Bi,Pb) 2 Sr 2 Ca 2 Cu 3 O 10 silver-sheathed tapes are discussed

  4. Development of quality assurance procedures for thermoluminescent CaSO sub 4 :Dy-teflon skived tape dosemeter

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Popli, K.L.; Kher, R.K.; Varadharajan, G. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1992-01-01

    CaSO{sub 4}:Dy-Teflon TLD dosemeter material has been manufactured locally in a 0.4 mm thick continuous tape form. Fourteen batches have been examined for physical thickness, density, spectral transmission, diffuse optical density, beta transmission and TL output per unit area for evolving a procedure for quality assurance of the TLD element for large scale production. With the exception of two batches, the TL output per unit area of the tape for a number of batches lies within {+-}7% of that for a standard batch. (author).

  5. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    Science.gov (United States)

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Moore's law realities for recording systems and memory storage components: HDD, tape, NAND, and optical

    Science.gov (United States)

    Fontana, Robert E.; Decad, Gary M.

    2018-05-01

    This paper describes trends in the storage technologies associated with Linear Tape Open (LTO) Tape cartridges, hard disk drives (HDD), and NAND Flash based storage devices including solid-state drives (SSD). This technology discussion centers on the relationship between cost/bit and bit density and, specifically on how the Moore's Law perception that areal density doubling and cost/bit halving every two years is no longer being achieved for storage based components. This observation and a Moore's Law Discussion are demonstrated with data from 9-year storage technology trends, assembled from publically available industry reporting sources.

  7. A high temperature superconductor tape RF receiver coil for a low field magnetic resonance imaging system

    International Nuclear Information System (INIS)

    Cheng, M C; Yan, B P; Lee, K H; Ma, Q Y; Yang, E S

    2005-01-01

    High temperature superconductor (HTS) thin films have been applied in making a low loss RF receiver coil for improving magnetic resonance imaging image quality. However, the application of these coils is severely limited by their limited field of view (FOV). Stringent fabrication environment requirements and high cost are further limitations. In this paper, we propose a simpler method for designing and fabricating HTS coils. Using industrial silver alloy sheathed Bi (2-x) Pb x Sr 2 Ca 2 Cu 3 O 10 (Bi-2223) HTS tapes, a five-inch single-turn HTS solenoid coil has been developed, and human wrist images have been acquired with this coil. The HTS tape coil has demonstrated an enhanced FOV over a six-inch YBCO thin film surface coil at 77 K with comparable signal-to-noise ratio

  8. EFFECT OF KINESIO TAPE VERSUS ATHLETIC TAPE ON MYOELECTRIC ACTIVITY OF ANKLE MUSCLES IN PATIENTS WITH CHRONIC ANKLE SPRAIN

    Directory of Open Access Journals (Sweden)

    Asmaa F Abdelmonem

    2018-04-01

    Full Text Available Background: Sprained ankle a common orthopedic injury. The standard treatment for ankle sprains remains nonoperative. Ankle taping was used to protect and prevent ligaments excessive strain. So, the current study aimed at investigating the effect of spa-care Kinesio tape versus standard white athletic tape on myoelectric activities (EMG of ankle evertors (peroneus longus and invertors (tibialis anterior in a chronic ankle sprain. Methods: A convenient sample of 30 patients with a chronic ankle sprain (18 females and 12 males were included in this study. Their mean age ±SD was 24 ±1.2 years. Their height was 175±4.8 cm among men & 163±5.2 cm for females, and weight was 85±5.2 kg for males & 74±5.5 kg for women. It was a within-group design in which the same participant experienced the two types of taping compared to no taping condition. Root mean square (RMS was measured while participants were moving the isokinetic dynamometer at an angular velocity of 120°/sec using concentric contraction mode through full ankle range of motion. The EMG (RMS of evertors and invertors was measured immediately after the three taping ways (no tape, Kinesio tape, and athletic tape with a one-week interval between each taping. Results: Spa-care Kinesiotape significantly reduced evertors and invertors EMG (RMS compared with no tape or athletic tape in patients with chronic ankle sprain. Mean± SD of the evertors was 0.7 (±0.1 for no tape and 0.58 (±0.2 for Kinesio tape. The P value was 0.000 for kinesio tape in evertors compared with no tape. Also, mean± SD of the invertors was 0.87 (±0.23 for no tape, and 0.54 (±0.1 for Kinesio tape and the P value was 0.001 for Kinesio tape in invertors compared with no tape. Conclusion: Spa-care Kinesio tape may be useful for reducing EMG activity of ankle muscles in a chronic ankle sprain.

  9. Flow structure and heat transfer in a square duct fitted with dual/quadruple twisted-tapes: Influence of tape configuration

    International Nuclear Information System (INIS)

    Eiamsa-ard, S.; Changcharoen, W.

    2015-01-01

    Numerical predictions reported of thermohydraulic characteristics of square ducts equipped with dual and quadruple twisted tapes (DTs and QTs) with different configurations. The studied cases include (1) dual co-tapes (Co-DTs), (2) dual counter-tapes (C-DTs), (3) diagonal dual counter-tapes (C-DDTs), (4) diagonal dual co-tapes (Co-DDTs), (5) quadruple co-tapes (Co-QTs), (6) quadruple counter tapes (CC-QTs) and (7) quadruple counter-tapes (PC-QTs). The results of these cases are compared with those of a smooth duct (a duct without tape insert) and also the one with a single tape (ST). The prediction involves using the RNG k-ε turbulent model under constant wall heat flux condition in the turbulent flow regime for the Reynolds number ranging from 6000 to 14000. The prediction indicates that thermohydraulic characteristics in ducts with twisted tape are strongly dependent on number and configuration of tapes. However, the influence of tape number is more significant than that of tape configuration. Heat transfer and friction increase as tape number increases. QTs offer superior heat transfer to DTs but their thermal performance factors are lower. For the tape inserts determined, DTs with diagonal configuration (Co-DDTs and C-DDTs) is the best design as the tapes offer the best thermal performance. The highest thermal performance factors given by Co-DTs, Co-DDTs, C-DTs, C-DDTs, Co-QTs, PC-QTs and CC-QTs, are around 1.21, 1.35, 1.25, 1.38, 1.08, 1.18, and 1.22, respectively

  10. Digital tape unit test facility software

    Science.gov (United States)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  11. Simulation of transport critical current of Bi2223/Ag tape with ferromagnetic shielding

    International Nuclear Information System (INIS)

    Gu, C.; Alamgir, A.K.M.; Qu, T.M.; Han, Z.

    2008-01-01

    Ferromagnetic shielding (FS) was coated onto the surface of the Bi2223/Ag multi-filamentary tape. Transport critical current of the Bi2223/Ag multi-filamentary tape with a FS was systematically studied by numerical simulation. In the help of a finite element analysis (FEA) tool, we are able to understand how the FS alters the flux inside the superconductor region and thus increases and decreases the critical current density locally. The results show the open FS function both positively and negatively to the performance of the tape. An optimization process was proposed, aiming to reach a tradeoff between I c increasing and less usage of the ferromagnetic material. Three important shielding parameters, shielding width, shielding thickness, and shielding material were taken into account

  12. Simulation of transport critical current of Bi2223/Ag tape with ferromagnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)], E-mail: guchen@tsinghua.edu.cn; Alamgir, A.K.M. [Faculty of Engineering, Yokohama National University, 75-9 Tokiwadai, Hodogaya, ku, Yokohama (Japan); Qu, T.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory for Advanced Materials Processing Technology, Ministry of Education (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)

    2008-09-15

    Ferromagnetic shielding (FS) was coated onto the surface of the Bi2223/Ag multi-filamentary tape. Transport critical current of the Bi2223/Ag multi-filamentary tape with a FS was systematically studied by numerical simulation. In the help of a finite element analysis (FEA) tool, we are able to understand how the FS alters the flux inside the superconductor region and thus increases and decreases the critical current density locally. The results show the open FS function both positively and negatively to the performance of the tape. An optimization process was proposed, aiming to reach a tradeoff between I{sub c} increasing and less usage of the ferromagnetic material. Three important shielding parameters, shielding width, shielding thickness, and shielding material were taken into account.

  13. A high critical current density MOCVD coated conductor with strong vortex pinning centers suitable for very high field use

    International Nuclear Information System (INIS)

    Chen, Z; Kametani, F; Larbalestier, D C; Chen, Y; Xie, Y; Selvamanickam, V

    2009-01-01

    We have made extensive low temperature and high field evaluations of a recent 2.1 μm thick coated conductor (CC) grown by metal-organic chemical vapor deposition (MOCVD) with a view to its use for high field magnet applications, for which its very strong Hastelloy substrate makes it very suitable. This conductor contains dense three-dimensional (Y,Sm) 2 O 3 nanoprecipitates, which are self-aligned in planes tilted ∼7 deg. from the tape plane. Very strong vortex pinning is evidenced by high critical current density J c values of ∼3.1 MA cm -2 at 77 K and ∼43 MA cm -2 at 4.2 K, and by a strongly enhanced irreversibility field H irr , which reaches that of Nb 3 Sn (∼28 T at 1.5 K) at 60 K, even in the inferior direction of H parallel c axis. At 4.2 K, J c values are ∼15% of the depairing current density J d , much the highest of any superconductor suitable for magnet construction.

  14. A high critical current density MOCVD coated conductor with strong vortex pinning centers suitable for very high field use

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z; Kametani, F; Larbalestier, D C [National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL 32310 (United States); Chen, Y; Xie, Y; Selvamanickam, V [SuperPower Incorporated, Schenectady, NY 12304 (United States)], E-mail: zhijun@asc.magnet.fsu.edu

    2009-05-15

    We have made extensive low temperature and high field evaluations of a recent 2.1 {mu}m thick coated conductor (CC) grown by metal-organic chemical vapor deposition (MOCVD) with a view to its use for high field magnet applications, for which its very strong Hastelloy substrate makes it very suitable. This conductor contains dense three-dimensional (Y,Sm){sub 2}O{sub 3} nanoprecipitates, which are self-aligned in planes tilted {approx}7 deg. from the tape plane. Very strong vortex pinning is evidenced by high critical current density J{sub c} values of {approx}3.1 MA cm{sup -2} at 77 K and {approx}43 MA cm{sup -2} at 4.2 K, and by a strongly enhanced irreversibility field H{sub irr}, which reaches that of Nb{sub 3}Sn ({approx}28 T at 1.5 K) at 60 K, even in the inferior direction of H parallel c axis. At 4.2 K, J{sub c} values are {approx}15% of the depairing current density J{sub d}, much the highest of any superconductor suitable for magnet construction.

  15. Bending strain study of Bi-2223/Ag tapes using Hall sensor magnetometry

    International Nuclear Information System (INIS)

    Lahtinen, M.; Paasi, J.; Sarkaniemi, J.; Han, Z.; Freltoft, T.

    1996-01-01

    The influence of room temperature bending on critical current (I c ) of Bi-2223/Ag tapes is studied by Hall sensor magnetometry, four-point method and scanning electron microscopy. Hall sensor magnetometry allows one to assess tape homogeneity and the amount of mechanical damage caused by bending. The microstructure of the Bi-2223 ceramic is found to strongly affect the tape behavior under bending strain. In a tape with moderate I c = 6.1 A at 77 K and a porous ceramic core, crack propagation took place normal to the Ag-ceramic interface, whereas in tapes with dense core, I c above 10 A at 77 K, cracks propagated in the tape plane. In monofilamentary tapes core homogeneity correlated with good bending strain performance. In multifilamentary tapes crack propagation between filaments was prohibited by the Ag matrix, thus leading to enhanced strain tolerance. In the high I c tapes studied, bending to 25 mm radius resulted in 1%--2% I c degradation

  16. DICOM implementation on online tape library storage system

    Science.gov (United States)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  17. A compact and bendable, hook-and-loop tape-based membraneless device for energy conversion

    International Nuclear Information System (INIS)

    Ortiz-Ortega, E; Ledesma-García, J; Gurrola, M P; Arriaga, L G; Arjona, N

    2016-01-01

    The new concept of a hook-and-loop tape-based membraneless device constructed on adhesive polyester film, which is fabricated using non-sophisticated and inexpensive fabrication techniques at room temperature, is presented. This concept overcomes the concerns about the reliability, versatility, weight, cost, lifetime and high performance of microfluidic fuel cell devices to satisfy the needs of portable energy applications. Current densities from 150 to 600 mA cm −2 and power densities from 40 to 132 mW cm −2 were achieved by varying the formic acid concentration, flow rates and by using air and dissolved oxygen as an oxidant. (paper)

  18. Award of two contracts for the renting of magnetic tape drives and tape libraries for LHC data storage and the purchase of the associated tape cartridges

    CERN Document Server

    2005-01-01

    This document concerns the award of two contracts for the renting and possible subsequent purchase of magnetic tape drives and tape libraries for LHC data storage. The Finance Committee is invited to agree to the procedure described in section 3 of this document for the evaluation and possible subsequent purchase of tape drives and tape libraries for the storage of data from the LHC experiments. Subject to approval of this procedure, the Finance Committee is further invited to approve the negotiation of a contract for the renting of tape drives and tape libraries for evaluation purposes from IBM, for an amount of 579 707 Swiss francs, and from StorageTek, for an amount of 472 297 Swiss francs, during the period January 2006 â?" March 2007, plus the purchase of the associated tape cartridges for amounts of 202 500 Swiss francs and 284 748 Swiss francs respectively. The Finance Committee will be informed of the results of the evaluation by the end of 2006 and, subject to the outcome, will be invited to approve...

  19. High critical current Ag and Ag alloy sheathed multifilament Bi-2223 tapes

    DEFF Research Database (Denmark)

    Wang, W.G.; Han, Z.; Skov-Hansen, P.

    1999-01-01

    of 0.16x2.8 mm(2) and silver/superconductor ratios of 4.4:1. By reducing the silver ratio, a J(e) of 14 kA/cm(2) with an I, of 38 A has been obtained in 55 filament tapes and an I-c of 84 A has been obtained in a tape with dimensions of 4x0.23 mm(2). A record J(c) of more than 30 kA/cm(2) with an I...

  20. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Wen-Dien Chang

    2015-01-01

    Full Text Available Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS. Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life.

  1. Nonlinear Model of Tape Wound Core Transformers

    Directory of Open Access Journals (Sweden)

    A. Vahedi

    2015-03-01

    Full Text Available Recently, tape wound cores due to their excellent magnetic properties, are widely used in different types of transformers. Performance prediction of these transformers needs an accurate model with ability to determine flux distribution within the core and magnetic loss. Spiral structure of tape wound cores affects the flux distribution and always cause complication of analysis. In this paper, a model based on reluctance networks method is presented for analysis of magnetic flux in wound cores. Using this model, distribution of longitudinal and transverse fluxes within the core can be determined. To consider the nonlinearity of the core, a dynamic hysteresis model is included in the presented model. Having flux density in different points of the core, magnetic losses can be calculated. To evaluate the validity of the model, results are compared with 2-D FEM simulations. In addition, a transformer designed for series-resonant converter and simulation results are compared with experimental measurements. Comparisons show accuracy of the model besides simplicity and fast convergence

  2. Magneto-optical and electromagnetic studies of core connectivity and weak-link behaviour in Cu/MgB2 and Ni/MgB2 wires and tapes

    International Nuclear Information System (INIS)

    Polyanskii, A; Beilin, V; Felner, I; Tsindlekht, M I; Yashchin, E; Dul'kin, E; Galstyan, E; Roth, M; Senkowicz, B; Hellstrom, E

    2004-01-01

    Critical current density, ac susceptibility (real part χ' and magneto-optical (MO) imaging were used to characterize round wire and tapes made from pre-reacted MgB 2 powder by the powder-in-tube method. Magnetic susceptibility measurements indicated the existence of large-scale weak-link networks in the cores of as-deformed Ni/MgB 2 and Cu/MgB 2 wires and tapes. As-deformed samples showed a two-step transition in χ' versus T traces as evidence of weak links in the tape core. The first heat treatment (HT) of as-deformed tapes led to a sharp susceptibility transition, very strong connection in the tape core as seen in MO images, and high critical current. A second rolling of an as-sintered tape induced a network of defects in the brittle core and gave rise to χ' curve broadening, but did not result in a two-step transition. These data show that deformation-induced cracks are not the primary source of weak-link behaviour. A large decrease in transport current was also registered in this sample. The second HT, for 30 min, restored the sharp magnetic transition and high transport current. Alternating areas of strong and weak connection in the tape core have been observed on MO images. Fast heating and cooling of the as-deformed tape with no dwell time at the maximum temperature resulted in a strongly linked core with a sharp transition and increased transport current. After fast HT, no mechanical defects were observed in MO images. Such fast transformation could be explained by rapid sintering due to highly strained MgB 2 grains

  3. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    Directory of Open Access Journals (Sweden)

    Biju Chetri

    2016-04-01

    Full Text Available Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected. The subjects were randomly divided into two groups i.e. Group A and Group B. Group A received taping, iontophoresis with plantar fascia stretching. Group B received taping and plantar fascia stretching. A total of 6 treatment sessions were given on alternate days over a period of two weeks for both the groups. Results: VAS and FFI scores across baseline and post intervention showed a significant improvement statistically in their mean scores between Groups A and B (P<0.05. Between group comparison of VAS and FFI scores, it showed that subject treated with Iontophoresis in combination with taping and plantar fascia stretch (Group A had significant improvement in VAS and functional ability when compared to subjects treated with taping and plantar fascia stretching alone (Group B. Conclusion: Iontophoresis along with Taping and plantar fascia stretching gave an additional benefit when compared with Taping and plantar fascia stretching alone in reducing pain and improving function in plantar fasciitis.

  4. Microstructure and superconducting properties of Bi-2223/Ag tapes fabricated in the two-step sintering process

    International Nuclear Information System (INIS)

    Lu, X.Y.; Nagata, A.; Sugawara, K.

    2008-01-01

    The microstructure and superconducting properties of Bi-2223/Ag tapes fabricated in the two-step sintering process were investigated. The tapes were then subjected to two heat treatments with an intermediate rolling. All the tapes were sintered at 835 deg. C for 24 h at initial sintering stage. A two-step sintering procedure was then used in the final sintering stage. In the first step, the tapes are sintered at 840-865 deg. C for 1 h. In the second step, they were sintered at 835 deg. C for 120 h. The results show that the first step sintering temperature has significant influence on the microstructure and the critical current density J c . The observed microstructures are consistent well with the different J c performances of the tapes first-step-sintered at different temperatures. The tape first-step-sintered at 850 deg. C, which has small secondary phases, stronger c-axis grain alignment, higher proportion of Bi-2223 phase, and no cracks, exhibits the highest J c value

  5. Immediate Effects of Sports Taping Applied on the Lead Knee of Low- and High-Handicapped Golfers During Golf Swing.

    Science.gov (United States)

    Kim, Tae-Gyu; Kim, Eun-Kuk; Park, Jong-Chul

    2017-04-01

    Kim, T-G, Kim, E-K, and Park, J-C. Immediate effects of sports taping applied on the lead knee of low- and high-handicapped golfers during golf swing. J Strength Cond Res 31(4): 981-989, 2017-Elite golf athletes suffer from various musculoskeletal injuries due to repeated golf swings. Repetitive varus moment during golf swing has been suggested as a possible cause of injuries to the lead knee. The aim of this study was to objectively and quantitatively evaluate the immediate effects of sports taping on the lead knee of elite golfers to restrict varus moment. Thirty-one elite golfers were assigned to the low- (LHG, n = 15) or high-handicapped group (HHG, n = 16). Using 3-dimensional motion analysis, the lead knee position on the frontal plane with and without rigid taping (RT), elastic taping (ET), and placebo taping was identified in 4 separate phases by the 5 events of golf swing as follows: the peak of the backswing (E1), parallel to the ground during downswing (E2), ball impact (E3), parallel to the ground during follow-through (E4), and finish (E5). The LHG when using a driver club had decreased movement toward knee varus with RT and ET than that without it from E1 to E2 (p = 0.001). The LHG when using a 5-iron club decreased movement toward knee varus with RT than that without it from E1 to E2 (p = 0.006) and from E2 to E3 (p = 0.019). The HHG when using a driver club had decreased movement toward knee varus with RT from E1 to E2 (p = 0.014). Sports taping may be helpful for elite golfers in terms of reducing varus moment of the lead knee during the downswing and be useful for the development of preventive strategies for golf-related knee injuries.

  6. Fix It with TAPE: Repurposing Technology to Be Assistive Technology for Students with High-Incidence Disabilities

    Science.gov (United States)

    Bouck, Emily C.; Shurr, Jordan C.; Tom, Kinsey; Jasper, Andrea D.; Bassette, Laura; Miller, Bridget; Flanagan, Sara M.

    2012-01-01

    This article discusses how practitioners can repurpose technology--common and socially desirable technology in particular--to be assistive technology for students with high-incidence disabilities. The authors provide a framework for practitioners to consider technology for repurposing: TAPE (Transportable, Available, Practical, Engaging) and…

  7. Carbon Nanotube-Based Synthetic Gecko Tapes

    Science.gov (United States)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  8. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the S...

  9. Degradation characteristics of 2G HTS tapes with respect to an electrical breakdown

    International Nuclear Information System (INIS)

    Kang, Jong O; Lee, On You; Mo, Young Kyu; Kim, Jun Il; Bang, Seung Min; Lee, Hong Seok; Kang, Hyoung Ku; Lee, Jae Hun; Jang, Cheol Yeong

    2015-01-01

    The electrical insulation design for a superconducting coil system is important for developing high voltage superconducting apparatuses. Also, the degraded characteristics of superconducting tapes due to an electrical breakdown should be considered for superconducting coils design. In this study, the degradation characteristics of 2G high temperature superconducting (HTS) tapes were studied with respect to electrical breakdown tests. The degradation tests of 2G HTS tapes were performed with various stabilizer materials. The degradation characteristics of 2G HTS tapes such as critical current(Ic) and index number were observed by performing electrical breakdown tests. It was found that the characteristics such as Ic and index number can be degraded by an electrical breakdown. Moreover, it was concluded that the degradation characteristics of 2G HTS tapes were affected by a stabilizer material and applied breakdown voltage. The cross sectional view of 2G HTS tapes was observed by using a scanning electron microscope (SEM). As results, it is found that the degradation characteristics of 2G HTS tapes are concerned with hardness and electrical resistivity of stabilizer layers

  10. Application for the Tape Station

    CERN Document Server

    Solero, A

    2003-01-01

    The Tape Station is used as an Isolde facility to observe the variations of intensity and the lifespan of certain isotopes. A Siemens Simatic FM-352-5 module controls the Tape Station in a PLC system then a DSC controls the PLC, which will be controlled the Tape station program. During the Isolde consolidation project, the Tape Station has been rebuilt, and the control system has been fully integrated in the PS control. Finally, a new application has been written in JAVA Development kit 1.4 and the PS Java environment. The main purpose of this note is to explain how to use this program.

  11. Cooperative doping effects of Ti and nano-SiC on transport critical current density and grain connectivity of in situ MgB{sub 2} tapes

    Energy Technology Data Exchange (ETDEWEB)

    Pan, X.F., E-mail: PAN.Xifeng@nims.go.jp [National Institute for Materials Science, Superconducting Materials Research Center, 1-2-1, Sengen, Tsukuba, Ibaraki 305-0047 (Japan)] [Key Laboratory of Magnetic Levitation and Maglev Trains (Ministry of Education of China), Superconductivity R and D Center (SRDC), Southwest Jiaotong University, Chengdu 610031 (China); Matsumoto, A.; Kumakura, H. [National Institute for Materials Science, Superconducting Materials Research Center, 1-2-1, Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Cheng, C.H.; Zhao, Y. [Key Laboratory of Magnetic Levitation and Maglev Trains (Ministry of Education of China), Superconductivity R and D Center (SRDC), Southwest Jiaotong University, Chengdu 610031 (China)] [School of Materials Science and Engineering, University of New South Wales, Sydney 2052, NSW (Australia)

    2011-11-15

    We studied the cooperative doping effects of Ti and nano-SiC on transport J{sub c} and grain connectivity of MgB{sub 2} tape. Ti doping significantly weakens the current dependence of T{sub c} of MgB{sub 2} tapes at self-field, and does not change T{sub c} or slightly increases T{sub c}. Further Ti adding can enhance in-field J{sub c} performance of SiC doped MgB{sub 2} tapes by a factor of 50-100% at 4.2 K and 10 T. Ti addition improves the J{sub c} performance of undoped and SiC doped MgB{sub 2} by modifying their grains connection. By now, nano-SiC powder (20-30 nm) is still the most effective additive for improving upper critical field and critical current density of MgB{sub 2}-based superconducting materials. However, some decomposed carbon aggregates at grain boundaries and results in serious weak-links of MgB{sub 2} grains, and these weak-links limit the further improvement of critical current density, J{sub c} of MgB{sub 2}, especially at lower fields. Ti doping is reported to increase the compactness of MgB{sub 2}, and modify its intergranular coupling by forming ultrathin TiB{sub 2} layer at grain boundaries. In this work, we studied the cooperative doping effects of Ti and nano-SiC on transport J{sub c} and grain connectivity of MgB{sub 2} and the possibility to improve transport J{sub c} of SiC doped MgB{sub 2} by introducing Ti additive. The results suggest the Ti addition can obviously improve J{sub c} of MgB{sub 2} at lower fields and also enhance the J{sub c} of SiC doped MgB{sub 2} by improving their grain connectivity which shows serious intergranular weak-links.

  12. Transport properties and exponential n-values of Fe/MgB2 tapes with various MgB2 particle sizes

    International Nuclear Information System (INIS)

    Lezza, P.; Abaecherli, V.; Clayton, N.; Senatore, C.; Uglietti, D.; Suo, H.L.; Fluekiger, R.

    2004-01-01

    Fe/MgB 2 tapes have been prepared starting with pre-reacted binary MgB 2 powders. As shown by resistive and inductive measurements, the reduction of particle size to a few microns by ball milling has little influence on B c2 , while the superconducting properties of the individual MgB 2 grains are essentially unchanged. Reducing the particle size causes an enhancement of B irr from 14 to 16 T, while J c has considerably increased at high fields, its slope J c (B) being reduced. At 4.2 K, values of 5.3 x 10 4 and 1.2 x 10 3 A/cm 2 were measured at 3.5 and 10 T, respectively, suggesting a dominant role of the conditions at the grain interfaces. A systematic variation of these conditions at the interfaces is undertaken in order to determine the limit of transport properties for Fe/MgB 2 tapes. The addition of 5% Mg to MgB 2 powder was found to affect neither J c nor B c2 . For the tapes with the highest J c values, very high exponential n factors were measured: n=148, 89 and 17 at 3.5, 5 and 10 T, respectively and measurements of critical current versus applied strain have been performed. The mechanism leading to high transport critical current densities of filamentary Fe/MgB 2 tapes based on MgB 2 particles is discussed

  13. The low-temperature, high-magnetic-field critical current characteristics of Zr-added (Gd, Y)Ba2Cu3Ox superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V; Yao, Y; Chen, Y; Shi, T; Liu, Y; Khatri, ND; Liu, J; Lei, C; Galstyan, E; Majkic, G

    2012-10-26

    Critical current performances of state-of-the-art Zr-added (Gd, Y)BaCuO tapes have been investigated over a temperature range of 20-77 K, in magnetic fields up to 9 T and over a wide angular range of magnetic field orientations. The peak in critical current that is commonly observed in the field orientation perpendicular to the tape in BaZrO3 (BZO) containing superconducting tapes is found to vanish at 30 K in magnetic fields at 1-9 T. While the critical current of 15% Zr-added tapes was about 40% lower than that of 7.5% Zr-added tapes at 77 K, the pinning force values of the former were found to be 18-23% higher than those of the latter in the temperature range of 20-40 K and in magnetic fields of 3-5 T. The results from this study emphasize the importance of optimization of coated conductor fabrication processes for optimum performance not just in low magnetic fields at 77 K but also at the operating conditions of low temperatures and high magnetic fields that are of interest, especially for rotating superconducting machinery applications.

  14. The low-temperature, high-magnetic-field critical current characteristics of Zr-added (Gd,Y)Ba2Cu3Ox superconducting tapes

    International Nuclear Information System (INIS)

    Selvamanickam, V; Yao, Y; Shi, T; Liu, Y; Khatri, N D; Liu, J; Galstyan, E; Majkic, G; Chen, Y; Lei, C

    2012-01-01

    Critical current performances of state-of-the-art Zr-added (Gd, Y)BaCuO tapes have been investigated over a temperature range of 20–77 K, in magnetic fields up to 9 T and over a wide angular range of magnetic field orientations. The peak in critical current that is commonly observed in the field orientation perpendicular to the tape in BaZrO 3 (BZO) containing superconducting tapes is found to vanish at 30 K in magnetic fields at 1–9 T. While the critical current of 15% Zr-added tapes was about 40% lower than that of 7.5% Zr-added tapes at 77 K, the pinning force values of the former were found to be 18–23% higher than those of the latter in the temperature range of 20–40 K and in magnetic fields of 3–5 T. The results from this study emphasize the importance of optimization of coated conductor fabrication processes for optimum performance not just in low magnetic fields at 77 K but also at the operating conditions of low temperatures and high magnetic fields that are of interest, especially for rotating superconducting machinery applications. (paper)

  15. Effect of kinesio-taping on ankle joint stability

    Directory of Open Access Journals (Sweden)

    Mervat A. Mohamed

    2016-05-01

    Full Text Available Ankle Instability is characterized by recurrent giving way and often develops after repeated lateral ankle sprains. Kinesiotape is more elastic than traditional athletic tape and is becoming increasingly popular. It is reported to decrease pain, improve muscle function, circulation and proprioception, however, research examining the effects of Kinesiotape in ankle instability is limited. The objective of this study was to determine if applying Kinesiotape to unstable ankle may improve performance in the Star Excursion Balance Test (SEBT, which has been shown to be a sensitive and reliable measure for quantifying dynamic balance. Thirty subjects with first degree ankle sprain were participated in this study. SEBT was used to test the subject dynamic balance under three conditions; without taping, with white athletic tape and with kinesiotape. One way repeated measure ANOVA using Greenhouse-Geisser corrections were conducted to evaluate differences in SEBT for the three conditions. Pairwise comparison of the outcome measures in the three occasions (without taping, with athletic taping, and with kinesio taping revealed statistically significant differences of all outcomes between occasion 1 (without taping and occasion 2 (with athletic taping favoring the athletic taping (p < 0.05. Also, a statistically significant difference between occasion 1 (without taping and occasion 3 (with kinesio taping were found (p < 0.05 favoring kinesio taping. Moreover, pairwise comparison of the ankle stability outcomes using athletic taping versus kinesio taping indicated a statistically significant difference (p < 0.05 in favor of kinesio taping measures. Conclusion: kinesiotape has superior effect than athletic tape in patients with first degree ankle sprain and can be used safely for improving ankle joint stability.

  16. Tape Storage and CRC Protection

    CERN Document Server

    Ha, Karel

    2014-01-01

    Over 100 Petabytes of data is stored on several kind of physical support, namely disks and tapes. Data on any physical support or traveling on a data link (network, fibre channel...) can be subject to silent data corruption. A possible improvement is introducing end-to-end data integrity from the filesystem down to the tape layer. For the tape back-end it can be done by using Logical Block Protection, which computes and compares CRC checksum of every single block of data. During my work, I improved on-the-fly CRC calculation for the tape storage system, which was achieved by introducing a multithreaded implementation - a technique applicable to arbitrary CRC algorithm. Finally, I per...

  17. Powder compaction characteristics and tube dimensions in PIT fabrication of Ag/BPSCCO superconducting tapes

    International Nuclear Information System (INIS)

    Sarma, M.S.; Syamaprasad, U.; Guruswamy, P.; Warrier, K.G.K.; Damodaran, A.D.; Mukherjee, P.S.

    1997-01-01

    Density variations of the superconductor core during the powder-in-tube (PIT) fabrication of Ag/BPSCCO monolayer tapes have been studied. The PIT procedure involved steps such as filling the tubes with precursor powder, rich in 2212 phase, with packing densities in the range 20-55% of theoretical density, groove rolling, flat rolling and finally a four-stage repeated rolling-annealing cycle. The two types of precursor powders used in this study were prepared by a conventional ceramic route and an amorphous acrylate route (AR). The core density was found to saturate after a few passes of just groove rolling for both powders. However, better compaction was achieved by rolling for the AR powder which also exhibited a better uniaxial compaction response. A further increase in core density was observed only during the final annealing step. Based on the experimentally observed constancy of core density through most of the mechanical working steps, a relation connecting silver sheath thickness, total thickness and cross-section ratio at saturation of compaction has been worked out. Apart from explaining the influence of starting packing density and compaction response of powder in determining the sheath thickness of the final tapes, the relationship was found to be useful in choosing the starting packing density appropriate to the silver tube dimensions and prevailing rolling conditions. (author)

  18. Modification of critical current in HTSC tape conductors by a ferromagnetic layer

    International Nuclear Information System (INIS)

    Goemoery, F; Souc, J; Seiler, E; Vojenciak, M; Granados, X

    2008-01-01

    In some applications of tape conductors from high temperature superconductors (HTSC) the magnetic field is created by the transported current itself. This is e.g. the case of power transmission cables or current leads. Quite complex distribution of local magnetic field determines then the ability of the superconducting element to carry electrical current. We have investigated how much the critical current of a tape conductor can be changed by putting a ferromagnetic layer in the vicinity of the HTSC material. Numerical procedure has been developed to resolve the current and field distribution in such superconductor-ferromagnet composite tape. Theoretical predictions have been confirmed by experiments on sample made from Bi-2223/Ag composite tape. The critical current of such tape can be improved by placing a soft ferromagnetic material at the tape's edges. On the other hand, the calculations show that the ferromagnetic substrate of YBCO coated tape reduces its self-field critical current

  19. Analisis Perilaku Konsumen Proll Tape di Jember

    OpenAIRE

    Kusmiati, Ati; Widjayanti, Lenny; Risaldi, Feri

    2009-01-01

    Proll tape is a agroindustrial product which used agriculture product as a basic material. It is a diversification product from tape and mixed with some flavour. It can be found in the gift store. Proll tape marketing strategic will influence consumer behaviour in the decision buying. Consumer buy proll tape as a gift as beside on their own consumption. Consumer considers proll tape has a good quality so that it can fill consumer needed. Purpose of the research to find out the influence facto...

  20. Nanostructured Gd-CeO2 electrolyte for solid oxide fuel cell by aqueous tape casting

    Science.gov (United States)

    Akbari-Fakhrabadi, A.; Mangalaraja, R. V.; Sanhueza, Felipe A.; Avila, Ricardo E.; Ananthakumar, S.; Chan, S. H.

    2012-11-01

    Gadolinia-doped ceria (Ce0.9Gd0.1O1.95, GDC) electrolyte was fabricated by aqueous-based tape casting method for solid oxide fuel cells (SOFCs). The ceramic powder prepared by combustion synthesis was used with poly acrylic acid (PAA), poly vinyl alcohol (PVA), poly ethylene glycol (PEG), Octanol, 2,4,7,9-tetramethyl-5-decyne-4,7-diol ethoxylate and double distilled water as dispersant, binder, plasticizer, defoamer, surfactant and solvent respectively, to prepare stable GDC slurry. The conditions for preparing stable GDC slurries were studied and optimized by sedimentation, zeta potential and viscosity measurements. Green tapes with smooth surface, flexibility, thickness in the range of 0.35-0.4 mm and 45% relative green density were prepared. Conventional and flash sintering techniques were used and compared for densification which demonstrated the possibility of surpassing sintering at high temperatures and retarding related grain growth.

  1. Enhancement of Critical Current Density and Flux Pinning in Acetone and La2O3 Codoped MgB2 Tapes

    International Nuclear Information System (INIS)

    Gao Zhao-Shun; Ma Yan-Wei; Wang Dong-Liang; Zhang Xian-Ping; Awaji Satoshi; Watanabe Kazuo

    2010-01-01

    MgB 2 tape samples with simultaneous additions of acetone and La 2 O 3 were prepared by an in-situ processed powder-in-tube method. Compared to the pure and single doped tapes, both transport J c and fluxing pinning are greatly improved by acetone and La 2 O 3 codoping. Acetone supplies carbon into the MgB 2 crystal lattice and increases the upper critical field, while the La 2 O 3 reacts with B to form LaB 6 nanoparticles as effective flux pining centers. The improvement of the superconducting properties in codoped tapes can be attributed to the combined effects of improvement in H c2 and flux pinning. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  2. A visualization instrument to investigate the mechanical-electro properties of high temperature superconducting tapes under multi-fields

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wei; Zhang, Xingyi, E-mail: zhangxingyi@lzu.edu.cn; Liu, Cong; Zhang, Wentao; Zhou, Jun; Zhou, YouHe [Key Laboratory of Mechanics on Disaster and Environment in Western China Attached to the Ministry of Education of China, Lanzhou University, Lanzhou, Gansu 730000, People’s Republic of China and Department of Mechanics and Engineering Sciences, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou, Gansu 730000 (China)

    2016-07-15

    We construct a visible instrument to study the mechanical-electro behaviors of high temperature superconducting tape as a function of magnetic field, strain, and temperature. This apparatus is directly cooled by a commercial Gifford-McMahon cryocooler. The minimum temperature of sample can be 8.75 K. A proportion integration differentiation temperature control is used, which is capable of producing continuous variation of specimen temperature from 8.75 K to 300 K with an optional temperature sweep rate. We use an external loading device to stretch the superconducting tape quasi-statically with the maximum tension strain of 20%. A superconducting magnet manufactured by the NbTi strand is applied to provide magnetic field up to 5 T with a homogeneous range of 110 mm. The maximum fluctuation of the magnetic field is less than 1%. We design a kind of superconducting lead composed of YBa2Cu3O7-x coated conductor and beryllium copper alloy (BeCu) to transfer DC to the superconducting sample with the maximum value of 600 A. Most notably, this apparatus allows in situ observation of the electromagnetic property of superconducting tape using the classical magnetic-optical imaging.

  3. Caught (Unfortunately) on Tape

    Science.gov (United States)

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  4. The effect of temperature and strain rate on the mechanical properties of highly oriented polypropylene tapes and all-polypropylene composites

    NARCIS (Netherlands)

    Alcock, B.; Cabrera, N.O.; Barkoula, N.M.; Reynolds, C.T.; Govaert, L.E.; Peijs, A.A.J.M.

    2007-01-01

    The creation of highly oriented, co-extruded polypropylene (PP) tapes allows the production of recyclable "all-polypropylene" (all-PP) composites, with a large temperature processing window and a high volume fraction of highly oriented PP (>90%). The wholly thermoplastic nature of these

  5. Lessons Learned in High Frequency Data Transmission Design: ATLAS Strips Bus Tape

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00213647; The ATLAS collaboration; Fadeyev, Vitaliy; Grillo, Alexander; Martinez-McKinney, George Forest; Phillips, Peter William; Sawyer, Craig; Sullivan, Stephanie W; Wastie, Roy; Weidberg, Anthony; Nielsen, Jason

    2017-01-01

    Requirements of HEP experiments lead to highly integrated systems with many electrical, mechanical and thermal constraints. A complex performance optimisation is therefore required. High speed data transmission lines are designed using copper-polyimide flexible bus tapes rather than cable harnesses to minimize radiation length. Methods to improve the signal integrity of point-to-point links and multi-drop configurations in an ultra-low-mass system are described. FEA calculations are an essential guide to the optimisation which allow data rates of 640 Mbps for point-to-point links over a length of up to 1.4m, as well as 160 Mbps for multi-drop configuration. The designs were validated using laboratory measurements of S-parameters and direct BER tests.

  6. Thermal conductivity measurement of HTS tapes and stacks for current lead applications

    International Nuclear Information System (INIS)

    Schwarz, Michael; Weiss, Klaus-Peter; Heller, Reinhard; Fietz, Walter H.

    2009-01-01

    The use of high-temperature-superconductors (HTS) within current leads offers a high potential to save cooling-power. The principle of HTS current leads is well established, e.g. for particle accelerators (LHC-CERN) but also on the commercial sector, which offer HTS current leads ready for use in small scale magnets and magnets systems. Future fusion machines currently under construction like ITER, W7-X or JT-60SA also will use HTS current leads. At the moment the standard material for HTS current leads is a Bi 2 Sr 2 Ca 2 Cu 3 O x (BSCCO)-AgAu composite tape. The common way to receive high current capacity current leads is to form stacks by sintering or soldering these tapes together. The solder changes the thermal conductivity of the stacks compared to the single tape in the temperature range from 4 K to 60 K. To estimate the heat flux from the warm environment to the cold application the measurement of the thermal conductivity of the soldered stack is mandatory. Therefore the thermal conductivity of stacks with different number of tapes is investigated. To measure the thermal conduction in the current flow direction, the axial heat flow method is used. Combining these results with FEM simulations gives the possibility to estimate the thermal conductivity normal to the flat tape plane. The resulting anisotropic thermal conductivity can be used to model the behaviour of the HTS tape under thermal disturbances more accurately.

  7. Superconducting fault current limiter using high-resistive YBCO tapes

    Energy Technology Data Exchange (ETDEWEB)

    Yazawa, T. [Power and Industrial System R and D Center, Toshiba Corporation, 2-4 Suehiro, Tsurumi, Yokohama 230-0045 (Japan)], E-mail: takashi.yazawa@toshiba.co.jp; Koyanagi, K.; Takahashi, M.; Ono, M.; Toba, K.; Takigami, H.; Urata, M. [Power and Industrial System R and D Center, Toshiba Corporation, 2-4 Suehiro, Tsurumi, Yokohama 230-0045 (Japan); Iijima, Y.; Saito, T. [Fujikura Ltd., 1-5-1 Kiba, Koto, Tokyo 135-0042 (Japan); Ameniya, N. [Yokohama National University, 79-1 Tokiwadai, Hodogaya, Yokohama 240-8501 (Japan); Shiohara, Y. [Superconductivity Research Laboratory, ISTEC, 1-10-13 Shinonome, Koto, Tokyo 135-0062 (Japan)

    2008-09-15

    One of the programs in the Ministry of Economy and Trade and Industry (METI) project regarding R and D on YBCO conductor is to evaluate the applicability of the developed conductor toward several applications. This paper focuses on a fault current limiter (FCL) as one of the expected power applications. YBCO tape conductors with ion beam assisted deposition (IBAD) substrate are used in this work. In order to obtain high resistance of the conductor, which is preferable to an FCL, the thickness of the protecting layer made of silver was decreased as possible. Then high-resistive metal stabilizing layer is attached on the silver layer to improve stability. Obtaining the relevant current limiting performance on short sample experiments, model coils were developed to aim the 6.6 kV-class FCL. Short circuit experiments were implemented with a short circuit generator. The coil successfully restricted the short circuit current over 17 kA to about 700 A by the applied voltage of 3.8 kV, which is nominal phase-to-ground voltage. The experimental results show good agreement with computer analyses and show promising toward the application.

  8. Thermomechanical Analysis of Shape-Memory Composite Tape Spring

    Science.gov (United States)

    Yang, H.; Wang, L. Y.

    2013-06-01

    Intelligent materials and structures have been extensively applied for satellite designs in order to minimize the mass and reduce the cost in the launch of the spacecraft. Elastic memory composites (EMCs) have the ability of high-strain packaging and shape-memory effect, but increase the parts and total weight due to the additional heating system. Shape-memory sandwich structures Li and Wang (J. Intell. Mater. Syst. Struct. 22(14), 1605-1612, 2011) can overcome such disadvantage by using the metal skin acting as the heating element. However, the high strain in the micro-buckled metal skin decreases the deployment efficiency. This paper aims to present an insight into the folding and deployment behaviors of shape-memory composite (SMC) tape springs. A thermomechanical process was analyzed, including the packaging deformation at an elevated temperature, shape frozen at the low temperature and shape recovery after reheating. The result shows that SMC tape springs can significantly decrease the strain concentration in the metal skin, as well as exhibiting excellent shape frozen and recovery behaviors. Additionally, possible failure modes of SMC tape springs were also analyzed.

  9. Safety brake for tape reels

    Science.gov (United States)

    Carle, C. E.

    1977-01-01

    All-mechanical device senses end of tape and stops reel, even in event of electronic system failure. Assembly includes stop to prevent brake from overriding tape. Recentering mechanism returns brake to neutral position after torque is removed from reels.

  10. Quantification of video-taped images in microcirculation research using inexpensive imaging software (Adobe Photoshop).

    Science.gov (United States)

    Brunner, J; Krummenauer, F; Lehr, H A

    2000-04-01

    Study end-points in microcirculation research are usually video-taped images rather than numeric computer print-outs. Analysis of these video-taped images for the quantification of microcirculatory parameters usually requires computer-based image analysis systems. Most software programs for image analysis are custom-made, expensive, and limited in their applicability to selected parameters and study end-points. We demonstrate herein that an inexpensive, commercially available computer software (Adobe Photoshop), run on a Macintosh G3 computer with inbuilt graphic capture board provides versatile, easy to use tools for the quantification of digitized video images. Using images obtained by intravital fluorescence microscopy from the pre- and postischemic muscle microcirculation in the skinfold chamber model in hamsters, Photoshop allows simple and rapid quantification (i) of microvessel diameters, (ii) of the functional capillary density and (iii) of postischemic leakage of FITC-labeled high molecular weight dextran from postcapillary venules. We present evidence of the technical accuracy of the software tools and of a high degree of interobserver reliability. Inexpensive commercially available imaging programs (i.e., Adobe Photoshop) provide versatile tools for image analysis with a wide range of potential applications in microcirculation research.

  11. The reduction of optimal heat treatment temperature and critical current density enhancement of ex situ processed MgB2 tapes using ball milled filling powder

    Science.gov (United States)

    Fujii, Hiroki; Iwanade, Akio; Kawada, Satoshi; Kitaguchi, Hitoshi

    2018-01-01

    The optimal heat treatment temperature (Topt) at which best performance in the critical current density (Jc) property at 4.2 K is obtained is influenced by the quality or reactivity of the filling powder in ex situ processed MgB2 tapes. Using a controlled fabrication process, the Topt decreases to 705-735 °C, which is lower than previously reported by more than 50 °C. The Topt decrease is effective to suppress both the decomposition of MgB2 and hence the formation of impurities such as MgB4, and the growth of crystallite size which decreases upper critical filed (Hc2). These bring about the Jc improvement and the Jc value at 4.2 K and 10 T reaches 250 A/mm2. The milling process also decreases the critical temperature (Tc) below 30 K. The milled powder is easily contaminated in air and thus, the Jc property of the contaminated tapes degrades severely. The contamination can raise the Topt by more than 50 °C, which is probably due to the increased sintering temperature required against contaminated surface layer around the grains acting as a barrier.

  12. Forensic utility of the carbon isotope ratio of PVC tape backings

    Science.gov (United States)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  13. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    OpenAIRE

    Biju Chetri, U.T. Ifthikar Ali, Madhusmita Koch, Abhijit Dutta

    2016-01-01

    Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected...

  14. How to improve J(c(T)) in Ag/(BiPb)2Sr2Ca2Cu3O10 tapes

    Science.gov (United States)

    Karkut, M.; Fossheim, K.

    1994-06-01

    We consider how to improve the magnetic field dependence of the critical current density J(c) in Ag/BSCCO superconducting tapes. First we look at mechanisms that provide pinning in the oxide superconductors and then consider the special problems that one encounters with Ag/BSCCO tapes. We propose several testable propositions to be performed in collaboration with NKT, Denmark and Tampere University, Finland.

  15. Strategy for robot motion and path planning in robot taping

    Science.gov (United States)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  16. Centrally managed tapes at DESY

    International Nuclear Information System (INIS)

    Hell, O.

    1994-01-01

    Tapes at DESY are managed by the computer center and thus offer virtually unlimited storage space to the DESY computer center users. This paper describes the most recent version of the DESY tape management system, its predecessors having been in service for many years

  17. Tape-cast sensors and method of making

    Science.gov (United States)

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  18. Investigation of Jc-Suppressing Factors in Flat-Rolled Sr0.6K0.4Fe2As2Fe Tapes Via Microstructure Analysis

    KAUST Repository

    Zhang, Xianping

    2015-01-13

    Pnictide superconductors will be very promising for applications if wires with high critical current density Jc can allow reel-to-reel large-scale fabrication at low costs. To understand the mechanism(s) that limited Jc in flat-rolled Sr0.6K0.4Fe2As2(Sr122) tapes, microstructure analysis has been considered the most direct and efficient way. Here, we report on high-resolution microstructure imaging and analysis on Fe-sheathed flat-rolled Sr122 tapes, which have a Jc as high as 2.3 × 104 A/cm2 at 10 T and 4.2 K. The overlapping nature of the Sr122 plates was clearly observed. Transmission electron microscopy/scanning transmission electron microscopy analysis showed that, besides the cracks formed during the fabrication process, the SrO2 phase and cavities caused by the inhomogeneously dispersed Sr and K are the other important factors suppressing Jc. The wetting phase FeAs at the grain boundaries can be partially substituted by Sn in Sn-added samples. Our findings provide insights that pave the way to further enhance the critical current of the rolled 122 tapes up to the practical level.

  19. Structural properties of superconducting Bi-2223/Ag tapes

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalck Andersen, L.

    2001-05-01

    The structural properties of silver clad high-T{sub c} superconducting ceramic tapes of (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub x} (Bi-2223) have been investigated by means of synchrotron X-ray diffraction (including the 3DXRD microscope setup), transmission electron microscopy (TEM) and scanning electron microscopy (SEM) with energy dispersive X-ray analysis (EDS). By synchrotron X-ray diffraction in situ studies of the phase development during the transformation of (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 1}Cu{sub 2}O{sub x} (Bi-2212) into Bi-2223, the stoichiometry changes and the texture have been performed during annealing in 8% O{sub 2} and in air. Furthermore, an annealing with two high temperature cycles has been performed to study the equilibrium phenomena. During heating (Ca,Sr){sub 2}PbO{sub 4} decomposes at temperatures between 700 deg. C and 840 deg.C. Simultaneously, the Bi-2212 lattice contracts, indicating an incorporation of Pb. Moreover, the grain mis-alignment decreases significantly. In air we have observed that Bi-2212 partly dissociates into (Ca,Sr){sub 2}CuO{sub 3} and a liquid at temperatures above 812 deg. C. At the annealing temperature Bi-2212 and (Ca,Sr){sub 2}CuO{sub 3} react with the liquid to form Bi-2223. The transformation mechanism is discussed. During cooling below {approx}750 deg.C (Ca,Sr){sub 2}CuO{sub 3} and the liquid mainly transform into Bi-2201. Below {approx}780 deg. C Bi-2223 decomposes to 3221. In addition, a two-step cooling experiment and a decomposition study have been performed in 8% O{sub 2}. By TEM the grain and colony size in the c-axis direction, the angles of c-axis tilt grain boundaries and the intergrowth content are investigated. A fully processed tape has on average 50% thicker grains than a tape after the 1st annealing. The angles of c-axis tilt grain boundaries are on average 14 deg. and 26 deg. for the fully processed tape and the tape after the 1st annealing, respectively. The intergrowth content (15%) and

  20. Preparation and characterization of Bi-2223 tapes

    International Nuclear Information System (INIS)

    Hense, K.; Kirchmayr, H.; Kovac, P.; Lackner, R.; Mueller, M.; Pachla, W.; Pitel, J.; Polak, M.; Usak, P.

    2003-01-01

    In a concerted action between Austrian, Slovakian and Polish research institutes Bi-2223 tapes have been prepared and characterized by different physical methods. Metallographic studies by optical as well as electron microscopy, measurements of critical current (angle dependent) and losses have been performed. Properties of individual filaments extracted from multifilamentary tapes were also studied. Uniformity of local I C of these filaments were considerably lower than that of the whole tape. This indicates that improvement of filament homogeneity could improve the over all J C in tapes. The application of these tapes for optimized magnet coils will also be discussed. From these investigations a better understanding of the mechanisms, limiting the critical current could be achieved and more optimized preparation methods can be envisioned

  1. Proposal for the Award of Two Contracts for the Supply of High Temperature SuperconductingTape for the LHC

    CERN Document Server

    2003-01-01

    This document concerns the award of two contracts for the supply of high temperature superconducting (HTS) BSCCO 2223 Ag-Au tape, of two different types, for the LHC. Following a call for tenders (IT-3143/AT/LHC) sent on 5 March 2003 to four firms in two Member States and one firm in the US, CERN received one tender from a firm in a Member State and one tender from the firm in the United States. The Finance Committee is invited to agree to the negotiation of contracts with: - VACUUMSCHMELZE (DE), for the supply of 17 km of HTS BSCCO 2223 Ag-Au tape with Ic > 66 A at 77 K for a total amount of 807 833 euros (1 201 900 Swiss francs), not subject to revision, with an option for the supply of up to additional 17 km of HTS BSCCO 2223 Ag-Au tape, for a total amount of up to 807 833 euros (1 201 900 Swiss francs), not subject to revision, bringing the total amount to a maximum of 1 615 666 euros (2 403 800 Swiss francs), not subject to revision. The rate of exchange used is that stipulated in the tender.

  2. New developments for the investigation of hard X-rays emitted by peeling adhesive tapes.

    Science.gov (United States)

    Krämer, D; Lützenkirchen-Hecht, D; Lühmann, B; Keite-Telgenbüscher, K; Frahm, R

    2013-05-01

    We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet.

  3. Comparison of growth texture in round Bi2212 and flat Bi2223 wires and its relation to high critical current density development

    OpenAIRE

    Kametani, F.; Jiang, J.; Matras, M.; Abraimov, D.; Hellstrom, E. E.; Larbalestier, D. C.

    2015-01-01

    Why Bi2Sr2CaCu2Ox (Bi2212) allows high critical current density Jc in round wires rather than only in the anisotropic tape form demanded by all other high temperature superconductors is important for future magnet applications. Here we compare the local texture of state-of-the-art Bi2212 and Bi2223 ((Bi,Pb)2Sr2Ca2Cu3O10), finding that round wire Bi2212 generates a dominant a-axis growth texture that also enforces a local biaxial texture (FWHM

  4. Delamination behaviour of GdBCO coated conductor tapes under transverse tension

    International Nuclear Information System (INIS)

    Gorospe, A.; Nisay, A.; Dizon, J.R.; Shin, H.S.

    2013-01-01

    Highlights: •Installation of a test frame which gives precisely aligned transverse load. •Investigation of I c degradation behaviour depending on the type of sample delamination. •Inhomogeneity of the CC tapes caused large variation on delamination strength. •SEM and EDS analysis of delamination sites under transverse loading. -- Abstract: The electromechanical property behaviour of 2G coated conductor (CC) tapes fabricated by multi-layer deposition process both in the in-plane and transverse direction should be understood. The CC tapes are used in the fabrication of epoxy resin-impregnated coils. In such case, the Lorentz force due to the high magnetic field applied as well as the thermal stress due to the difference in coefficient of thermal expansion (CTE) among constituent layers during cooling to cryogenic temperature will induce transversely applied load to the surface of CC tapes in coils. Hence, the CC tape should have a good mechanical property in the transverse direction in order to maintain its superior performance under magnetic field. In this study, a test frame which gives precisely aligned transverse load was devised. Using the fixture, the delamination behaviours including the delamination strength of the GdBCO CC tapes under transverse tensile loading were investigated. Large variation on the delamination strength of the CC tapes was recorded and might have resulted from the slit edge effect and the inhomogeneity of the CC tapes. The I c degradation behaviour under transverse load was related to the location where delamination occurred in the sample

  5. Research on resistance characteristics of YBCO tape under short-time DC large current impact

    Science.gov (United States)

    Zhang, Zhifeng; Yang, Jiabin; Qiu, Qingquan; Zhang, Guomin; Lin, Liangzhen

    2017-06-01

    Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance - temperature change rule and the maximum impact current. The influence of insulation for the resistance - temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.

  6. Low toxicity binder systems for tape cast Ce0.9Gd0.1O1.95 laminates

    DEFF Research Database (Denmark)

    Klemensø, Trine; Menon, Mohan; Ramousse, Severine

    2010-01-01

    Conventional binder systems for tape casting contain toxic phthalate plasticizers and butanone (MEK) as part of the solvent. The effects of exchanging the phthalate with a non-toxic alternative, and butanone with ethanol, were studied on laminates of high-green density CGO (Ce0.9Gd0.1O1.95) tapes....... Samples were prepared with a binder system containing DBP (dibutyl phthalate) plasticizer and MEK solvent, and with a binder system based on a non-toxic non-phthalate plasticizer and ethanol. In both systems, the weight ratio of plasticizer to the PVB (polyvinyl butyral) binder was varied between 0.......4 and 0.7. Substitution to the less toxic binder system had no adverse impacts on the microstructure. In fact, denser packing and improved homogeneity were observed with the non-phthalate-based system at ratio 0.5 indicating improved dispersion in this system. The denser packing also coincided...

  7. Electric currents in REBaCuO superconducting tapes

    Czech Academy of Sciences Publication Activity Database

    Jirsa, Miloš; Rameš, Michal; Ďuran, Ivan; Melíšek, T.; Kováč, P.; Viererbl, L.

    2017-01-01

    Roč. 30, č. 4 (2017), 1-8, č. článku 045010. ISSN 0953-2048 EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:68378271 ; RVO:61389021 Keywords : superconducting tapes * REBaCuO * critical currents * induction and transport * pinning force density * magnetic relaxation * neutron irradiation Subject RIV: BM - Solid Matter Physics ; Magnetism; BL - Plasma and Gas Discharge Physics (UFP-V) OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.); Fluids and plasma physics (including surface physics) (UFP-V) Impact factor: 2.878, year: 2016

  8. Analysis of twisted tape solutions for cooling of the residual ion dump of the ITER HNB

    Energy Technology Data Exchange (ETDEWEB)

    Ochoa Guamán, Santiago, E-mail: santiago.ochoa@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Technical Physics, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Hanke, Stefan [Karlsruhe Institute of Technology (KIT), Institute for Technical Physics, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Sartori, Emanuele; Palma, Mauro Dalla [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padua (Italy)

    2016-11-01

    Highlights: • Due to manufacturing deviations, the cooling channels are made by double side drilling. • Twisted tapes with two different thicknesses are necessary for a better cooling performance. • The manufacturing of cooling channels and twisted tapes was demonstrated to be feasible. • The water critical heat flux safety margin is higher than 1.5 for the total channel length. • Geometry optimization shown better cooling performance and higher CHF safety margins. - Abstract: The ITER HNB residual ion dump is exposed to a heat load about 17 MW on the dump panels with a peak power density of 7 MW/m{sup 2}. Water flows through cooling channels, 2 m long and 14 mm diameter, realized by double side deep drilling. Unavoidable manufacturing deviations could generate a discontinuity at the channel length center. It is necessary to verify the influence of issues such as cavitation, fluid stagnation, low boiling margins, among others, in the cooling performance. Assuming worst case conditions, analytical and CFD methods showed a subcooled boiling operation with high safety margins to the water critical heat flux. Additionally, by analysing several thermo-hydraulic parameters, the twisted tape cross sections were optimized. Per cooling channel, two twisted tapes are inserted from the sides of the panels, thus, a study of a separation gap between them at the channel length center presented an optimal distance. This paper demonstrates that common machining techniques and drilling tolerances allow the manufacturing of panels able to withstand safely the required beam operation heat loads, even under worst case operation scenarios.

  9. BALLISTIC RESISTANT ARTICLES COMPRISING TAPES

    NARCIS (Netherlands)

    VAN DER EEM, JORIS; HARINGS, JULES; JANSE, GERARDUS; TJADEN, HENDRIK

    2015-01-01

    The invention pertains to a ballistic-resistant moulded article comprising a compressed stack of sheets comprising reinforcing tapes having a tensile strength of at least 1.0 GPa, a tensile modulus of at least 40 GPa, and a tensile energy-to-break of at least 15 J/g, the direction of the tapes

  10. Design of double tape recorder data acquisition system

    International Nuclear Information System (INIS)

    Guo Tianrui; Du Yifei

    1995-01-01

    In the data acquisition system supported by the microcomputer tape recorder, as the acquisition speed is often limited by the low speed of tape recorder, so a double tape recorder system is designed. In this system, two tape recorders are used in on-line acquisition system simultaneously. One DMA channel used is one designed for soft disk driver, another DMA channel used is one retained for user. By this way, the speed of tape writing could be increased to nearly twice as much. In order to prevent the data confusion, the authors open two data buffers in system and write different mark in each buffer, then write the data block to two tape recorders according to the mark. The system complies with the principle: 'Double write, Double read'

  11. Modelling and measurement of ac loss in BSCCO/Ag-tape windings

    International Nuclear Information System (INIS)

    Oomen, M P; Nanke, R; Leghissa, M

    2003-01-01

    High-temperature superconducting (HTS) transformers promise decreased weight and volume and higher efficiency. A 1 MVA HTS railway transformer was built and tested at Siemens AG. This paper deals with the prediction of ac loss in the BSCCO/Ag-tape windings. In a railway transformer the tape carries ac current in alternating field, the temperature differs from 77 K, tapes are stacked or cabled and overcurrents and higher harmonics occur. In ac-loss literature these issues are treated separately, if at all. We have developed a model that predicts the ac loss in sets of BSCCO/Ag-tape coils, and deals with the above-mentioned issues. The effect of higher harmonics on the loss in HTS tapes is considered for the first time. The paper gives a complete overview of the model equations and required input parameters. The model is validated over a wide range of the input parameters, using the measured critical current and ac loss of single tapes, single coils and sets of coils in the 1 MVA transformer. An accuracy of around 25% is achieved in all relevant cases. Presently the model is developed further, in order to describe other HTS materials and other types of applications

  12. Comparison of novel ultra-high molecular weight polyethylene tape versus conventional metal wire for sublaminar segmental fixation in the treatment of adolescent idiopathic scoliosis.

    Science.gov (United States)

    Takahata, Masahiko; Ito, Manabu; Abumi, Kuniyoshi; Kotani, Yoshihisa; Sudo, Hideki; Ohshima, Shigeki; Minami, Akio

    2007-08-01

    Retrospective study. To compare the surgical outcomes of posterior translational correction and fusion using hybrid instrumentation systems with either sublaminar Nesplon tape or sublaminar metal wire to treat adolescent idiopathic scoliosis (AIS). Nesplon tape, which consists of a thread of ultra-high molecular weight polyethylene fibers, has advantages over metal wire: (1) its soft and flexible properties avoid neural damage and (2) its flat configuration avoids focal distribution of the stresses to lamina; however, the efficacy of Nesplon tape in the correction of spinal deformity is as yet, still unclear. Thirty AIS patients at a single institution underwent posterior correction and fusion using hybrid instrumentation containing hook, pedicle screw, and either sublaminar polyethylene taping (15) or sublaminar metal wiring (15). Patients were evaluated preoperatively, immediately after surgery, and at a 2-year follow-up according to the radiographic changes in curve correction, operating time, intraoperative blood loss, complications, and the Scoliosis Research Society patient questionnaire (SRS-24) score. The average correction rate was 63.0% in the Nesplon tape group and 59.9% in the metal wire group immediately after surgery (P = 0.62). Fusion was obtained in all the patients without significant correction loss in both groups. There was no significant difference in operative time, intraoperative blood loss, and postoperative SRS-24 scores between the 2 groups. Complications were superficial skin infection in a single patient in the Nesplon tape group, and transient sensory disturbance in 1 patient and temporal superior mesenteric artery syndrome in another patient in the metal wire group. The efficacy of Nesplon tape in correction of deformity is equivalent to that of metal wire, and fusion was completed without significant correction loss. The soft and flexible properties and flat configuration of Nesplon tape make this a safe application for the treatment

  13. Urinary incontinence - tension-free vaginal tape

    Science.gov (United States)

    ... ency/article/007377.htm Urinary incontinence - tension-free vaginal tape To use the sharing features on this page, please enable JavaScript. Placement of tension-free vaginal tape is surgery to help control stress urinary ...

  14. Field dependence of the current density of superconductors at high temperatures

    International Nuclear Information System (INIS)

    Hiergeist, R.; Hergt, R.; Erb, A.; Kummeth, P.; Winzer, K.

    1993-01-01

    An essential drawback of the high-T c superconductors (HTS) with respect to technical applications at liquid nitrogen temperature is the large degradation of their pinning properties in magnetic fields. For the field dependence of the volume pinning force often a high field tail due to thermally activated flux flow is observed. An exponential decay of the irreversible magnetization with increasing field was reported in the case of sintered material (YBCO) for the intergranular part of the magnetization while a power law decay was found for the intragranular part. Song et al. observed an exponential field dependence of the critical current density for proton-irradiated material which before irradiation showed a power law decay. Gladun et al. found an exponential decay for BSCCO-2223 tapes. The high field behaviour of BSCCO was shown to be governed by thermally activated flux creep with a logarithmic pinning barrier, which may result in an exponential decrease of the current with the external magnetic field, as argued recently by Ries et al. We will show in the present paper that the different HTS substance classes (YBCO, BSCCO, TBCCO) behave qualitatively in a similar way. (orig.)

  15. Electromechanical characterization of superconducting wires and tapes at 77 K

    CERN Document Server

    Bjoerstad, Roger

    The strain dependency of the critical current in state-of-the-art cuprate high-temperature superconductors (HTS) has been characterized. A universal test machine (UTM) combined with a critical current measurement system has been used to characterize the mechanical and the superconducting properties of conductors immersed in an open liquid nitrogen dewar. A set-up has been developed in order to perform simultaneous measurements of the superconductor lattice parameter changes, critical current, as well as the stress and strain at 77 K in self-field in a high energy synchrotron beamline. The HTS tapes and wires studied were based on YBCO, Bi-2223 and Bi-2212. The YBCO tapes were produced by SuperPower and American Superconductors (AMSC). Two types of Bi-2223 tapes, HT and G, were produced by Sumitomo Electric Industries (SEI). The Bi-2212 wires were produced by Oxford Superconducting Technology (OST) using Nexans granulate precursor, before undergoing a specialized over pressure (OP) processing and heat treatmen...

  16. Experimental Investigations of Woven Textile Tape as Strain Sensor

    Science.gov (United States)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  17. Tape SCSI monitoring and encryption at CERN

    Science.gov (United States)

    Laskaridis, Stefanos; Bahyl, V.; Cano, E.; Leduc, J.; Murray, S.; Cancio, G.; Kruse, D.

    2017-10-01

    CERN currently manages the largest data archive in the HEP domain; over 180PB of custodial data is archived across 7 enterprise tape libraries containing more than 25,000 tapes and using over 100 tape drives. Archival storage at this scale requires a leading edge monitoring infrastructure that acquires live and lifelong metrics from the hardware in order to assess and proactively identify potential drive and media level issues. In addition, protecting the privacy of sensitive archival data is becoming increasingly important and with it the need for a scalable, compute-efficient and cost-effective solution for data encryption. In this paper, we first describe the implementation of acquiring tape medium and drive related metrics reported by the SCSI interface and its integration with our monitoring system. We then address the incorporation of tape drive real-time encryption with dedicated drive hardware into the CASTOR [1] hierarchical mass storage system.

  18. PERFORMANCE CHARACTERISTICS OF PARABOLIC SOLAR COLLECTOR WATER HEATER SYSTEM FITTED WITH NAIL TWISTED TAPES ABSORBER

    Directory of Open Access Journals (Sweden)

    K. SYED JAFAR

    2017-03-01

    Full Text Available In this paper, the experimental heat transfer, friction loss and thermal performance data for water flowing through the absorber tube fitted with two different twisted tape configurations in parabolic trough collector (PTC are presented. In the present work, a relative experimental study is carried out to investigate the performance of a PTC influenced by heat transfer through fluidabsorber wall mixing mechanism. The major findings of this experiment show that heat transport enhancement in the nail twisted tape collector perform significantly better than plain twisted tapes and also show that the smallest twisted tape ratio enhances the system performance remarkably maximizing the collector efficiency. The results suggest that the twisted tape and nail twisted tape would be a better option for high thermal energy collection in laminar region of the PTC system.

  19. Effect of binder concentration and blade gap on Yttria stabilized Zirconia tapes obtained by tape casting

    Energy Technology Data Exchange (ETDEWEB)

    Mena Garcia, J.; Reyes Rojas, A.; Rodriguez Gonzalez, C.A.; Hernandez Paz, J.; Garcia Casillas, P.E.; Enriquez Carrejo, J.L.; Camacho Montes, H.

    2016-07-01

    The tape casting method has kept its interest over the years due to the wide spectrum of its applications and its economic viability in comparison to other techniques focused on micrometric thin films. Two key parameters for tape casting are the binder relative amount and the Dr. Blade gap. The binder relative amount has a strong influence on the rheological properties for the ceramic YSZ slurry (ethanol, butanone, TEA, PVB, PEG, DEP). The coefficient K and the exponent m of the Cross model are reported to be inside the ranges 152.25-231.12 and 0.00987-0.26646 for PVB binder weight percentage concentrations between 6% and 12%. It is possible to describe the ceramic tape thickness dependence by means of a linear relation depending on the Dr. Blade gap whose linear coefficients (slope) are equal to 0.0350 and 0.2171 for green and sintered tapes respectively, with the YSZ slurry of the present work. (Author)

  20. High-Power-Density, High-Energy-Density Fluorinated Graphene for Primary Lithium Batteries

    Directory of Open Access Journals (Sweden)

    Guiming Zhong

    2018-03-01

    Full Text Available Li/CFx is one of the highest-energy-density primary batteries; however, poor rate capability hinders its practical applications in high-power devices. Here we report a preparation of fluorinated graphene (GFx with superior performance through a direct gas fluorination method. We find that the so-called “semi-ionic” C-F bond content in all C-F bonds presents a more critical impact on rate performance of the GFx in comparison with sp2 C content in the GFx, morphology, structure, and specific surface area of the materials. The rate capability remains excellent before the semi-ionic C-F bond proportion in the GFx decreases. Thus, by optimizing semi-ionic C-F content in our GFx, we obtain the optimal x of 0.8, with which the GF0.8 exhibits a very high energy density of 1,073 Wh kg−1 and an excellent power density of 21,460 W kg−1 at a high current density of 10 A g−1. More importantly, our approach opens a new avenue to obtain fluorinated carbon with high energy densities without compromising high power densities.

  1. Laser-assisted patterning of double-sided adhesive tapes for optofluidic chip integration

    Science.gov (United States)

    Zamora, Vanessa; Janeczka, Christian; Arndt-Staufenbiel, Norbert; Havlik, George; Queisser, Marco; Schröder, Henning

    2018-02-01

    Portable high-sensitivity biosensors exhibit a growing demand in healthcare, food industry and environmental monitoring sectors. Optical biosensors based on photonic integration platforms are attractive candidates due to their high sensitivity, compactness and multiplexing capabilities. However, they need a low-cost and reliable integration with the microfluidic system. Laser-micropatterned double-sided biocompatible adhesive tapes are promising bonding layers for hybrid integration of an optofluidic biochip. As a part of the EU-PHOCNOSIS project, double-sided adhesive tapes have been proposed to integrate the polymer microfluidic system with the optical integrated waveguide sensor chip. Here the adhesive tape should be patterned in a micrometer scale in order to create an interaction between the sample that flows through the polymer microchannel and the photonic sensing microstructure. Three laser-assisted structuring methods are investigated to transfer microchannel patterns to the adhesive tape. The test structure design consists of a single channel with 400 μm wide, 30 mm length and two circular receivers with 3 mm radius. The best structuring results are found by using the picosecond UV laser where smooth and straight channel cross-sections are obtained. Such patterned tapes are used to bond blank polymer substrates to blank silicon substrates. As a proof of concept, the hybrid integration is tested using colored DI-water. Structuring tests related to the reduction of channel widths are also considered in this work. The use of this technique enables a simple and rapid manufacturing of narrow channels (50-60 μm in width) in adhesive tapes, achieving a cheap and stable integration of the optofluidic biochip.

  2. Mechanical properties and bending strain effect on Cu-Ni sheathed MgB2 superconducting tape

    International Nuclear Information System (INIS)

    Fu, Minyi; Chen, Jiangxing; Jiao, Zhengkuan; Kumakura, H.; Togano, K.; Ding, Liren; Zhang, Yong; Chen, Zhiyou; Han, Hanmin; Chen, Jinglin

    2004-01-01

    The Young's modulus (E) of Cu-Ni sheathed MgB 2 monofilament tape was measured using electric method. It is about 8.05 x 10 10 Pa, the same order of Cu and its alloys. We found that the lower E value of the MgB 2 component seemed to relate to the lower filament density. The benefits of pre-compression in filaments were discussed in terms of improving stress distribution in the wires and tapes during winding and operation of superconducting magnets. The magnetic field dependence of J c was investigated on the sample subjected to various strain levels through bending with different radii at 4.2 K

  3. Test results of a 20 kA high temperature superconductor current lead using REBCO tapes

    Science.gov (United States)

    Heller, R.; Fietz, W. H.; Gröner, F.; Heiduk, M.; Hollik, M.; Lange, C.; Lietzow, R.

    2018-05-01

    The Karlsruhe Institute of Technology has developed a 20 kA high temperature superconductor (HTS) current lead (CL) using the second generation material REBCO, as industry worldwide concentrate on the production of this material. The aim was to demonstrate the possibility of replacing the Bi-2223/AgAu tapes by REBCO tapes, while for easy comparison of results, all other components are copies of the 20 kA HTS CL manufactured for the satellite tokamak JT-60SA. After the manufacture of all CL components including the newly developed REBCO module, the assembly of the CL has been executed at KIT and an experiment has been carried out in the CuLTKa test facility where the REBCO CL was installed and connected to a JT-60SA CL via a superconducting bus bar. The experiment covers steady state operation up to 20 kA, pulsed operation, measurement of the heat load at 4.5 K end, loss-of-flow-accident simulations, and quench performance studies. Here the results of these tests are reported and directly compared to those of the JT-60SA CL.

  4. Melt processing of Yb-123 tapes

    International Nuclear Information System (INIS)

    Athur, S. P.; Balachandran, U.; Salama, K.

    2000-01-01

    The innovation of a simple, scalable process for manufacturing long-length conductors of HTS is essential to potential commercial applications such as power cables, magnets, and transformers. In this paper the authors demonstrate that melt processing of Yb-123 tapes made by the PIT route is an alternative to the coated conductor and Bi-2223 PIT tape fabrication techniques. Ag-clad Yb-123 tapes were fabricated by groove rolling and subsequently, melt processed in different oxygen partial pressures in a zone-melting furnace with a gradient of 140 C/cm. The transition temperatures measured were found to be around 81 K undermost processing conditions. EPMA of the tapes processed under different conditions show the 123 phase to be Ba deficient and Cu and Yb rich. Critical current was measured at various temperatures from 77 K to 4.2 K. The J c increased with decrease in pO 2 . The highest I c obtained was 52 A at 4.2 K

  5. Evaluation of plasma-wave spectral density from cross-power spectra

    International Nuclear Information System (INIS)

    Ilic, D.B.; Harker, K.J.

    1975-01-01

    The plasma-wave spectral density is evaluated by performing a spatial Fourier transform on experimental cross-power spectra of ion acoustic waves. The cross-power spectra are recorded on analog magnetic tape, converted to digital form, transferred to digital magnetic tape, and Fourier transformed on a digital computer. The important effects of sampling, finite data strings, and data smoothing on the end results are discussed and illustrated. The results indicate the usefulness of the spectral density method for the study of nonlinear wave phenomena. (auth)

  6. Double disordered YBCO coated conductors of industrial scale: high currents in high magnetic field

    International Nuclear Information System (INIS)

    Abraimov, D; Francis, A; Jaroszynski, J; McCallister, J; Polyanskii, A; Santos, M; Viouchkov, Y L; Ballarino, A; Bottura, L; Rossi, L; Barth, C; Senatore, C; Dietrich, R; Rutt, A; Schlenga, K; Usoskin, A; Majkic, G S; Selvamanickam, V

    2015-01-01

    A significant increase of critical current in high magnetic field, up to 31 T, was recorded in long tapes manufactured by employing a double-disorder route. In a double-disordered high-temperature superconductor (HTS), a superimposing of intrinsic and extrinsic disorder takes place in a way that (i) the intrinsic disorder is caused by local stoichiometry deviations that lead to defects of crystallinity that serve as pining centers in the YBa 2 Cu 3 O x−δ matrix and (ii) the extrinsic disorder is introduced via embedded atoms or particles of foreign material (e.g. barium zirconate), which create a set of lattice defects. We analyzed possible technological reasons for this current gain. The properties of these tapes over a wider field-temperature range as well as field anisotropy were also studied. Record values of critical current as high as 309 A at 31 T, 500 A at 18 Tm and 1200 A at 5 T were found in 4 mm wide tape at 4.2 K and B perpendicular to tape surface. HTS layers were processed in medium-scale equipment that allows a maximum batch length of 250 m while 22 m long batches were provided for investigation. Abnormally high ratios (up to 10) of critical current density measured at 4.2 K, 19 T to critical current density measured at 77 K, self-field were observed in tapes with the highest in-field critical current. Anisotropy of the critical current as well as angular dependences of n and α values were investigated. The temperature dependence of critical current is presented for temperatures between 4.2 and 40 K. Prospects for the suppression of the dog-bone effect by Cu plating and upscale of processing chain to >500 m piece length are discussed. (paper)

  7. Double disordered YBCO coated conductors of industrial scale: high currents in high magnetic field

    Science.gov (United States)

    Abraimov, D.; Ballarino, A.; Barth, C.; Bottura, L.; Dietrich, R.; Francis, A.; Jaroszynski, J.; Majkic, G. S.; McCallister, J.; Polyanskii, A.; Rossi, L.; Rutt, A.; Santos, M.; Schlenga, K.; Selvamanickam, V.; Senatore, C.; Usoskin, A.; Viouchkov, Y. L.

    2015-11-01

    A significant increase of critical current in high magnetic field, up to 31 T, was recorded in long tapes manufactured by employing a double-disorder route. In a double-disordered high-temperature superconductor (HTS), a superimposing of intrinsic and extrinsic disorder takes place in a way that (i) the intrinsic disorder is caused by local stoichiometry deviations that lead to defects of crystallinity that serve as pining centers in the YBa2Cu3O x-δ matrix and (ii) the extrinsic disorder is introduced via embedded atoms or particles of foreign material (e.g. barium zirconate), which create a set of lattice defects. We analyzed possible technological reasons for this current gain. The properties of these tapes over a wider field-temperature range as well as field anisotropy were also studied. Record values of critical current as high as 309 A at 31 T, 500 A at 18 Tm and 1200 A at 5 T were found in 4 mm wide tape at 4.2 K and B perpendicular to tape surface. HTS layers were processed in medium-scale equipment that allows a maximum batch length of 250 m while 22 m long batches were provided for investigation. Abnormally high ratios (up to 10) of critical current density measured at 4.2 K, 19 T to critical current density measured at 77 K, self-field were observed in tapes with the highest in-field critical current. Anisotropy of the critical current as well as angular dependences of n and α values were investigated. The temperature dependence of critical current is presented for temperatures between 4.2 and 40 K. Prospects for the suppression of the dog-bone effect by Cu plating and upscale of processing chain to >500 m piece length are discussed.

  8. Towards a 20 kA high temperature superconductor current lead module using REBCO tapes

    Science.gov (United States)

    Heller, R.; Bagrets, N.; Fietz, W. H.; Gröner, F.; Kienzler, A.; Lange, C.; Wolf, M. J.

    2018-01-01

    Most of the large fusion devices presently under construction or in operation consisting of superconducting magnets like EAST, Wendelstein 7-X (W7-X), JT-60SA, and ITER, use high temperature superconductor (HTS) current leads (CL) to reduce the cryogenic load and operational cost. In all cases, the 1st generation HTS material Bi-2223 is used which is embedded in a low-conductivity matrix of AgAu. In the meantime, industry worldwide concentrates on the production of the 2nd generation HTS REBCO material because of the better field performance in particular at higher temperature. As the new material can only be produced in a multilayer thin-film structure rather than as a multi-filamentary tape, the technology developed for Bi-2223-based current leads cannot be transferred directly to REBCO. Therefore, several laboratories are presently investigating the design of high current HTS current leads made of REBCO. Karlsruhe Institute of Technology is developing a 20 kA HTS current lead using brass-stabilized REBCO tapes—as a further development to the Bi-2223 design used in the JT-60SA current leads. The same copper heat exchanger module as in the 20 kA JT-60SA current lead will be used for simplicity, which will allow a comparison of the newly developed REBCO CL with the earlier produced and investigated CL for JT-60SA. The present paper discusses the design and accompanying test of single tape and stack REBCO mock-ups. Finally, the fabrication of the HTS module using REBCO stacks is described.

  9. Perceived Organizational Red Tape and Organizational Performance in Public Services

    DEFF Research Database (Denmark)

    Jacobsen, Christian Bøtcher; Jakobsen, Mads Leth

    2018-01-01

    The claim that perceived organizational red tape hampers public services has become a central theme in public administration research. Surprisingly, however, few scholars have empirically examined the impact of perceived red tape on organizational performance. This study empirically analyzes how...... perceived organizational red tape among managers and frontline staff relates to objectively measured performance. The data consists of survey responses from teachers and principals at Danish upper secondary schools combined with grade-level administrative performance data. Based on theories of red tape...... and motivation crowding, we hypothesize that perceived organizational red tape reduces performance within such organizations. The empirical result is a small, negative relationship between staff perception of red tape and performance, and no relationship between manager-perceived red tape and performance....

  10. The effect of the ceramic core initial phase composition on the Ag-sheathed Bi-2223 tapes critical properties

    International Nuclear Information System (INIS)

    Nikulin, A.D.; Shikov, A.K.; Khlebova, N.E.; Antipova, E.V.; Dontsova, E.V.; Kazakov, E.G.; Medvedev, M.I.; Kozlenkova, N.I.; Shishov, V.N.; Akimov, I.I.

    1993-01-01

    Ag - sheathed superconducting tapes were fabricated using ''powder-in-tube'' method with powders of Bi 1.6 Pb 0.4 Sr 2 Ca 2 Cu 3.2 O x chemical composition prepared by the ''freeze-drying'' tecnique and taken as a core materials. The effect of ceramic core initial phase composition: the mixture of oxide non-superconducting phases - OP (typeI) and 50% OP + 50% OP ''2212''- phase (type II) on the critical current density was investigated as well as the ''annealing - cold pressing'' parameters. Multifilamentary superconducting tapes and the pancake coils were fabricated. (orig.)

  11. A possibility of enhancing Jc in MgB2 film grown on metallic hastelloy tape with the use of SiC buffer layer

    International Nuclear Information System (INIS)

    Putri, W. B. K.; Kang, B.; Ranot, M.; Lee, J. H.; Kang, W. N.

    2014-01-01

    We have grown MgB 2 on SiC buffer layer by using metallic Hastelloy tape as the substrate. Hastelloy tape was chosen for its potential practical applications, mainly in the power cable industry. SiC buffer layers were deposited on Hastelloy tapes at 400, 500, and 600 degrees C by using a pulsed laser deposition method, and then by using a hybrid physical-chemical vapor deposition technique, MgB 2 films were grown on the three different SiC buffer layers. An enhancement of critical current density values were noticed in the MgB 2 films on SiC/Hastelloy deposited at 500 and 600 degrees C. From the surface analysis, smaller and denser grains of MgB 2 tapes are likely to cause this enhancement. This result infers that the addition of SiC buffer layers may contribute to the improvement of superconducting properties of MgB 2 tapes.

  12. Systematic Review of the Effect of Taping Techniques on Patellofemoral Pain Syndrome.

    Science.gov (United States)

    Logan, Catherine A; Bhashyam, Abhiram R; Tisosky, Ashley J; Haber, Daniel B; Jorgensen, Anna; Roy, Adam; Provencher, Matthew T

    Taping is commonly used in the management of several musculoskeletal conditions, including patellofemoral pain syndrome (PFPS). Specific guidelines for taping are unknown. To investigate the efficacy of knee taping in the management of PFPS. Our hypothesis was that tension taping and exercise would be superior to placebo taping and exercise as well as to exercise or taping alone. The PubMed/MEDLINE, Cochrane, Rehabilitation and Sports Medicine Source, and CINAHL databases were reviewed for English-language randomized controlled trials (RCTs) evaluating the efficacy of various taping techniques that were published between 1995 and April 2015. Keywords utilized included taping, McConnell, kinesio-taping, kinesiotaping, patellofemoral pain, and knee. Studies included consisted of RCTs (level 1 or 2) with participants of all ages who had anterior knee or patellofemoral pain symptoms and had received nonsurgical management using any taping technique. Systematic review. Level 2. A checklist method was used to determine selection, performance, detection, and attrition bias for each article. A quality of evidence grading was then referenced using the validated PEDro database for RCTs. Three difference comparison groups were compared: tension taping and exercise versus placebo taping and exercise (group 1), placebo taping and exercise versus exercise alone (group 2), and tension taping and exercise versus taping alone (group 3). Five RCTs with 235 total patients with multiple intervention arms were included. Taping strategies included McConnell and Kinesiotaping. Visual analog scale (VAS) scores indicated improvement in all 3 comparison groups (group 1: 91 patients, 39% of total, mean VAS improvement 44.9 [tension taping + exercise] vs 66 [placebo taping + exercise]; group 2: 56 patients, 24% of total, mean VAS improvement 66 [placebo taping + exercise] vs 47.6 [exercise alone]; and group 3: 112 patients, 48% of total, mean VAS improvement 44.9 [tension taping + exercise

  13. Melt formed superconducting joint between superconducting tapes

    International Nuclear Information System (INIS)

    Benz, M.G.; Knudsen, B.A.; Rumaner, L.E.; Zaabala, R.J.

    1992-01-01

    This patent describes a superconducting joint between contiguous superconducting tapes having an inner laminate comprised of a parent-metal layer selected from the group niobium, tantalum, technetium, and vanadium, a superconductive intermetallic compound layer on the parent-metal layer, a reactive-metal layer that is capable of combining with the parent-metal and forming the superconductive intermetallic compound, the joint comprising: a continuous precipitate of the superconductive intermetallic compound fused to the tapes forming a continuous superconducting path between the tapes

  14. Multiple Generations on Video Tape Recorders.

    Science.gov (United States)

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  15. Investigation of the influence on residual stresses of porosity in high temperature ZrO2 coatings on Ag tape for magnet technologies

    International Nuclear Information System (INIS)

    Arman, Yusuf; Aktas, Mehmet; Celik, Erdal; Mutlu, Ibrahim H.; Sayman, Onur

    2007-01-01

    The present paper reports on the effect on residual stresses of porosity in high temperature ZrO 2 coatings on Ag tape for magnet technologies. ZrO 2 coatings were fabricated on Ag tape substrate using a reel-to-reel sol-gel system. The microstructural evolution of high temperature ZrO 2 coatings was investigated by a scanning electron microscope (SEM). SEM observations revealed that ZrO 2 coatings with crack had some porosity and mosaic structure. Stress analysis was carried out on ZrO 2 coatings with porosity on Ag tape substrates under cryogenic conditions by using classical lamination theory (CLT) for elastic solution and finite element method (FEM) for elasto-plastic solution in the temperature range of 0 o C to -223 o C in liquid helium media. Because of the static equilibrium, tensile force is applied to the Ag substrate, by ZrO 2 coating. The stress component (σ x ) values change rapidly at coating-substrate interface owing to the different moduli of elasticity and thermal expansion coefficient. In spite of the thickness of Ag substrate, the stress components vary from tensile to compressive. In addition, along the thickness of ZrO 2 coating and Ag substrate system, the stress distribution changes linearly. FEM results demonstrate that the failure does not occur in ZrO 2 coating for all porosities due to its high yield strength

  16. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    International Nuclear Information System (INIS)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan; Yang, Xinsheng; Zhao, Yong

    2015-01-01

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  17. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Yang, Xinsheng, E-mail: xsyang@swjtu.edu.cn [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Zhao, Yong [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Superconductivity Research Group, School of Materials Science and Engineering, University of New South Wale, Sydney 2052, NSW (Australia)

    2015-12-15

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  18. Development of a test procedure for cryogenic adhesive tapes; Entwicklung einer Testprozedur fuer kryogene Klebebaender

    Energy Technology Data Exchange (ETDEWEB)

    Funke, Thomas; Haberstroh, Christoph [TU Dresden (Germany). Bitzer-Professur fuer Kaelte-, Kryo- und Kompressorentechnik; Mayrhofer, Robert; Stipsitz, Johannes [RUAG Space GmbH, Wien (Austria)

    2016-07-01

    At cryostats and dewars for lowest temperatures - especially in connection with liquid-helium cooling at around 4 K, as well at the most applications of the superconductivity - often joints and shutters on the base of low-temperature suited adhesive tapes are required. A current method for the thermal isolation of cold surfaces is their covering with highly reflecting aluminium foils, which are fastened by adhesive aluminium tapes. Selection, usage, and reliability estimation of presumably suited adhesive tapes respectively aluminium tapes occurs presently rather heuristically. A corresponding testing apparature for the measurement of the maximal pulling force was developed and tested by means of a series of test measurements. The testing set-up and measurement results for the validation of the measurement concept with adhesive aluminium tapes are presented in this contribution.

  19. Visualization of latent fingerprints beneath opaque electrical tapes by optical coherence tomography

    Science.gov (United States)

    Liu, Kangkang; Zhang, Ning; Meng, Li; Li, Zhigang; Xu, Xiaojing

    2018-03-01

    Electrical tape is found as one type of important trace evidence in crime scene. For example, it is very frequently used to insulate wires in explosive devices in many criminal cases. The fingerprints of the suspects were often left on the adhesive side of the tapes, which can provide very useful clues for the investigation and make it possible for individual identification. The most commonly used method to detect and visualize those latent fingerprints is to peel off each layer of the tapes first and then adopt the chemical methods to develop the fingerprints on the tapes. However, the peeling-off and chemical development process would degrade and contaminate the fingerprints and thus adversely affect the accuracy of identification. Optical coherence tomography (OCT) is a novel forensic imaging modality based on lowcoherence interferometry, which has the advantages of non-destruction, micrometer-level high resolution and crosssectional imaging. In this study, a fiber-based spectral-domain OCT (SD-OCT) system with {6μm resolution was employed to obtain the image of fingerprint sandwiched between two opaque electrical tapes without any pre-processing procedure like peeling-off. Three-dimensional (3D) OCT reconstruction was performed and the subsurface image was produced to visualize the latent fingerprints. The results demonstrate that OCT is a promising tool for recovering the latent fingerprints hidden beneath opaque electrical tape non-destructively and rapidly.

  20. Probes for investigating the effect of magnetic field, field orientation, temperature and strain on the critical current density of anisotropic high-temperature superconducting tapes in a split-pair 15 T horizontal magnet.

    Science.gov (United States)

    Sunwong, P; Higgins, J S; Hampshire, D P

    2014-06-01

    We present the designs of probes for making critical current density (Jc) measurements on anisotropic high-temperature superconducting tapes as a function of field, field orientation, temperature and strain in our 40 mm bore, split-pair 15 T horizontal magnet. Emphasis is placed on the design of three components: the vapour-cooled current leads, the variable temperature enclosure, and the springboard-shaped bending beam sample holder. The vapour-cooled brass critical-current leads used superconducting tapes and in operation ran hot with a duty cycle (D) of ~0.2. This work provides formulae for optimising cryogenic consumption and calculating cryogenic boil-off, associated with current leads used to make J(c) measurements, made by uniformly ramping the current up to a maximum current (I(max)) and then reducing the current very quickly to zero. They include consideration of the effects of duty cycle, static helium boil-off from the magnet and Dewar (b'), and the maximum safe temperature for the critical-current leads (T(max)). Our optimized critical-current leads have a boil-off that is about 30% less than leads optimized for magnet operation at the same maximum current. Numerical calculations show that the optimum cross-sectional area (A) for each current lead can be parameterized by LI(max)/A = [1.46D(-0.18)L(0.4)(T(max) - 300)(0.25D(-0.09)) + 750(b'/I(max))D(10(-3)I(max)-2.87b') × 10⁶ A m⁻¹ where L is the current lead's length and the current lead is operated in liquid helium. An optimum A of 132 mm(2) is obtained when I(max) = 1000 A, T(max) = 400 K, D = 0.2, b' = 0.3 l h(-1) and L = 1.0 m. The optimized helium consumption was found to be 0.7 l h(-1). When the static boil-off is small, optimized leads have a boil-off that can be roughly parameterized by: b/I(max)  ≈ (1.35 × 10(-3))D(0.41) l h(‑1) A(-1). A split-current-lead design is employed to minimize the rotation of the probes during the high current measurements in our high

  1. Probes for investigating the effect of magnetic field, field orientation, temperature and strain on the critical current density of anisotropic high-temperature superconducting tapes in a split-pair 15 T horizontal magnet

    International Nuclear Information System (INIS)

    Sunwong, P.; Higgins, J. S.; Hampshire, D. P.

    2014-01-01

    We present the designs of probes for making critical current density (J c ) measurements on anisotropic high-temperature superconducting tapes as a function of field, field orientation, temperature and strain in our 40 mm bore, split-pair 15 T horizontal magnet. Emphasis is placed on the design of three components: the vapour-cooled current leads, the variable temperature enclosure, and the springboard-shaped bending beam sample holder. The vapour-cooled brass critical-current leads used superconducting tapes and in operation ran hot with a duty cycle (D) of ∼0.2. This work provides formulae for optimising cryogenic consumption and calculating cryogenic boil-off, associated with current leads used to make J c measurements, made by uniformly ramping the current up to a maximum current (I max ) and then reducing the current very quickly to zero. They include consideration of the effects of duty cycle, static helium boil-off from the magnet and Dewar (b ′ ), and the maximum safe temperature for the critical-current leads (T max ). Our optimized critical-current leads have a boil-off that is about 30% less than leads optimized for magnet operation at the same maximum current. Numerical calculations show that the optimum cross-sectional area (A) for each current lead can be parameterized by LI max /A=[1.46D −0.18 L 0.4 (T max −300) 0.25D −0.09 +750(b ′ /I max )D 10 −3 I max −2.87b ′ ]× 10 6 A m −1 where L is the current lead's length and the current lead is operated in liquid helium. An optimum A of 132 mm 2 is obtained when I max = 1000 A, T max = 400 K, D = 0.2, b ′ = 0.3 l h −1 and L = 1.0 m. The optimized helium consumption was found to be 0.7 l h −1 . When the static boil-off is small, optimized leads have a boil-off that can be roughly parameterized by: b/I max  ≈ (1.35 × 10 −3 )D 0.41 l h ‑1  A −1 . A split-current-lead design is employed to minimize the rotation of the probes during the high current measurements in

  2. Preparing superconducting nanopowder based YBCO/Ag tapes

    DEFF Research Database (Denmark)

    Paturi, P.; Raittila, J.; Grivel, J.C.

    2002-01-01

    YBCO nanopowder consisting of 1-3 nm thick and 40 nm wide particles has been used to make silver clad superconducting tapes. After annealing in nitrogen at 945 degreesC for 10 h a critical current of 5.02 A (3300 A/cm(2)) was attained, Annealing in mixed atmosphere of oxygen and nitrogen was also...... carried out and this procedure produced tapes with a critical current of 2.83 A (2200 A/cm(2)). These tapes show very good characteristics in magnetic fields. (C) 2002 Elsevier Science B.V. All rights reserved....

  3. Effect of composition on the fabrication and properties of Ag-Cu alloy sheathed (Bi,Pb)2223 tapes

    International Nuclear Information System (INIS)

    Nakamura, Yuichi; Nakashima, Sohei; Inada, Ryoji; Oota, Akio

    2004-01-01

    To achieve high J c values as well as high mechanical strength, the effects of Ag-Cu alloy sheath and initial composition of precursor on the microstructure and J c properties of Ag-Cu alloy sheathed tapes were investigated. The alkaline-earth cuprate particles were found to form preferentially near the interface between superconducting core and sheath. Although the worse (Bi,Pb)2223 purity and microstructure of alloy sheathed tapes, the reduction of J c values of the tapes was small especially in 7-filaments tapes. This might be explained by the well grain alignment of (Bi,Pb)2223 into the middle region of the filament due to the high strength of alloy sheath. The usage of the Cu deficient composition was effective to reduce the total amount of 14:24 particle while the filament thickness should be thin to maintain J c values for Ag-Cu alloy sheathed tapes due to the lack of Cu diffusion from the sheath to convert 2212 into (Bi,Pb) in the middle region of the filament

  4. Study of the inhomogeneity of critical current under in-situ tensile stress for YBCO tape

    Science.gov (United States)

    Zhu, Y. P.; Chen, W.; Zhang, H. Y.; Liu, L. Y.; Pan, X. F.; Yang, X. S.; Zhao, Y.

    2018-07-01

    A Hall sensor system was used to measure the local critical current of YBCO tape with high spatial resolution under in-situ tensile stress. The hot spot generation and minimum quench energy of YBCO tape, which depended on the local critical current, was calculated through the thermoelectric coupling model. With the increase in tensile stress, the cracks which have different dimensions and critical current degradation arose more frequently and lowered the thermal stability of the YBCO tape.

  5. Fabrication of Polyimide-Matrix/Carbon and Boron-Fiber Tape

    Science.gov (United States)

    Belvin, Harry L.; Cano, Roberto J.; Treasure, Monte; Shahood, Thomas W.

    2007-01-01

    The term HYCARB denotes a hybrid composite of polyimide matrices reinforced with carbon and boron fibers. HYCARB and an improved process for fabricating dry HYCARB tapes have been invented in a continuing effort to develop lightweight, strong composite materials for aerospace vehicles. Like other composite tapes in this line of development, HYCARB tapes are intended to be used to build up laminated structures having possibly complex shapes by means of automated tow placement (ATP) - a process in which a computer-controlled multiaxis machine lays down prepreg tape or tows. The special significance of the present process for making dry HYCARB for ATP is that it contributes to the reduction of the overall cost of manufacturing boron-reinforced composite-material structures while making it possible to realize increased compression strengths. The present process for making HYCARB tapes incorporates a "wet to dry" process developed previously at Langley Research Center. In the "wet to dry" process, a flattened bundle of carbon fiber tows, pulled along a continuous production line between pairs of rollers, is impregnated with a solution of a poly(amide acid) in N-methyl-2-pyrrolidinone (NMP), then most of the NMP is removed by evaporation in hot air. In the present case, the polyamide acid is, more specifically, that of LaRC. IAX (or equivalent) thermoplastic polyimide, and the fibers are, more specifically, Manganite IM7 (or equivalent) polyacrylonitrile- based carbon filaments that have a diameter of 5.2 m and are supplied in 12,000-filament tows. The present process stands in contrast to a prior process in which HYCARB tape was made by pressing boron fibers into the face of a wet carbon-fiber/ poly(amide acid) prepreg tape . that is, a prepreg tape from which the NMP solvent had not been removed. In the present process, one or more layer(s) of side-by-side boron fibers are pressed between dry prepreg tapes that have been prepared by the aforementioned gwet to dry h

  6. Experimental Tape Casting of Adjacently Graded Materials for Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Bulatova, Regina

    encompass modification of the entire tape caster into a multi chamber unit, establishment of the optimal operating parameters such as casting gap, speed, and slurry level in the tape caster reservoir, and elucidation of the impact of chamber partition design on the quality of the final tape. The second...... of the side-by-side tape casting technique: recognising critical parameters which affect the quality of a graded tape, shape and position of the interface area. Studied parameters can be divided into two categories: operational parameters and slurry formulation optimisation. The operational parameters...

  7. Characteristics of joint resistance with different kinds of HTS tapes for heater trigger switch

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Je Yull; Park, Young Gun; Lee, Woo Seung; Jo, Hyun Chul; Ko, Tae Kuk [Yonsei University, Seoul (Korea, Republic of); Yoon, Yong Soo [Shin Ansan University, Ansan (Korea, Republic of)

    2014-03-15

    Recently, many researches on the system of superconducting power supply and superconducting magnetic energy storage (SMES) using high temperature superconducting (HTS) tapes has been progressed. Those kinds of superconducting devices use the heater trigger switches that have a control delay problem at moments of heating up and cooling down. One way to reduce the time delay is using a different HTS tape at trigger part. For example, HTS tape having lower critical temperature can reduce time delay of heating up and heating down stage for heater trigger operation. This paper deals with resistances joint with different kinds of HTS tapes which have different properties to verify usefulness of the suggested method. Three kinds of commercial HTS tapes with different specifications are selected as samples and two kinds of solders are used for comparison. Joint is performed with temperature and pressure controllable joint machine and the joint characteristics are analyzed under the repeatable conditions.

  8. Magnetic imaging of superconducting tapes to determine current flow

    Energy Technology Data Exchange (ETDEWEB)

    Brown, G. W. (Geoffrey W.); Hawley, M. E. (Marilyn E.); Foltyn, S. R. (Stephen R.); Mueller, F. M. (Fred M.)

    2001-01-01

    We have developed a magnetic imaging system that uses magnetoresistive read heads from computer hard disk drives to map the transport-current-induced magnetic field at the surface of superconducting tapes at liquid nitrogen temperature. Transport current pathways are determined from the 2-dimensional magnetic field maps using established inversion schemes. We examined the current flow in pulsed-laser-deposited YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} a films patterned on single crystal SrTiO{sub 3} substrates and on a textured yttria-stabilized-zirconia layer deposited on an Inconel ribbon by ion beam assisted deposition. The transport current densities in all cases were consistent with the Critical State Model. For the Inconel-based sample, the transport current density maps have allowed us to observe defects and determine the region that limits the current carrying capacity of the structure.

  9. The effect of tape casting operational parameters on the quality of adjacently graded ceramic film

    DEFF Research Database (Denmark)

    Bulatova, Regina; Gudik-Sørensen, Mads; Della Negra, Michela

    2016-01-01

    For small length tape casting of ceramic slurries varying green film thickness is often a problem. To optimise this, the following parameters were investigated: single blade, double blade, using a pump system and a modelled speed change mode have been analysed. Advantages and limitations of every...... method are described here. The tape casting experiments were built to be generic in order to allow the control of various processing conditions. From these results, the single-blade technique was chosen for a study of side-by-side tape casting. The influence of the geometric parameters of partitioning...... the casting tank into chambers, on the quality of graded tape was studied. Tape casting experiments at different speeds and partition tongue lengths in combination with rheological tests revealed that high casting speeds and absence of the partition under the blade are detrimental to the formation...

  10. Influence of transverse compressive stress on Ic degradation of Ag alloy sheathed Bi-2223 tapes

    International Nuclear Information System (INIS)

    Oh, S S; Ha, D W; Ha, H S; Park, C; Kwon, Y K; Ryu, K S; Shin, H S

    2004-01-01

    In order to investigate the degradation of critical current (I c ) in the Ag alloy sheathed Bi-2223 tapes due to a transverse compressive stress introduced during manufacturing and operation of the HTS systems, a sample holder consisting of the upper block made of Ti alloy and the lower support plate made of glass fibre reinforced plastic was prepared. A shorter spacing of voltage taps caused large degradation of critical current with respect to compressive stress. It was found that the extent of the I c degradation is proportional to the initial critical current density of the tapes. Through the experiment optimizing the shape of voltage terminals and the pressing load for the continuous contact type 4-probe I c measurement system, it was found that the conical shape tip with large curvature radius was effective in suppressing the I c degradation in Bi-2223 tapes during the I c measurement. A hard alloy sheath of Ag-0.6wt%Mn was found to be quite tolerant to the I c degradation against the pressing load of voltage terminals

  11. Tamper tape seals

    International Nuclear Information System (INIS)

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R ampersand D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique open-quotes fingerprintclose quotes characteristics that can be accessed as desired

  12. Disentangled solid state and metastable polymer melt; a solvent free route to high-modulus high-strength tapes and films of UHMWPE

    Science.gov (United States)

    Rastogi, Sanjay

    2013-03-01

    Ultra High Molecular Weight Polyethylene (UHMWPE) having average molar mass greater than a million g/mol is an engineering polymer. Due to its light-weight, high abrasion resistance and biocompatibility it is used for demanding applications such as body armour, prostheses etc. At present, because of its high melt viscosity to achieve the uniaxial/biaxial properties in the form of fibers/films the polymer is processed via solution route where nearly 95wt% of the solvent is used to process 5wt% of the polymer. In past several attempts have been made to process the polymer without using any solvent. However, compared to the solvent processing route the achieved mechanical properties were rather poor. Here we show that by controlled synthesis it is feasible to obtain UHMWPE that could be processed free of solvent to make uniaxial tapes and biaxial films, having unprecedented mechanical properties, exceeding that of the solution spun fibers. We address some of the fundamental aspects of chemistry, physics, rheology and processing for the development of desired morphological features to achieve the ultimate mechanical properties in tapes and films. The paper will also address the metastable melt state obtained on melting of the disentangled crystals and its implication on rheology in linear and nonlinear viscoelastic region. Solid state NMR studies will be applied to establish disentangled state in solid state to the polymerisation conditions. References: Macromolecules 2011, 44(14), 5558-5568; Nature Materials 2005, 4, 635-641; Phys Rev Lett 2006, 96(21), 218303-218205. The authors acknowledge financial support by the Dutch Polymer Institute.

  13. Kinesio Taping Fundamentals for the Equine Athlete.

    Science.gov (United States)

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Multi-level, automatic file management system using magnetic disk, mass storage system and magnetic tape

    International Nuclear Information System (INIS)

    Fujii, Minoru; Asai, Kiyoshi

    1979-12-01

    A simple, effective file management system using magnetic disk, mass storage system (MSS) and magnetic tape is described. Following are the concepts and techniques introduced in this file management system. (1) File distribution and continuity character of file references are closely approximated by memory retention function. A density function using the memory retention function is thus defined. (2) A method of computing the cost/benefit lines for magnetic disk, MSS and magnetic tape is presented. (3) A decision process of an optimal organization of file facilities incorporating file demands distribution to respective file devices, is presented. (4) A method of simple, practical, effective, automatic file management, incorporating multi-level file management, space management and file migration control, is proposed. (author)

  15. Numerical and Experimental Investigation of the Electromechanical Behavior of REBCO Tapes

    Science.gov (United States)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2015-12-01

    To fully characterize the electromechanical behavior of a Twisted Stacked-Tape Cable (TSTC) it is important to understand the performance of the individual REBCO tapes under various loading conditions. Numerical modeling and experimentation have been used to investigate the electromechanical characteristics of two commercially available REBCO tapes (SuperPower and SuNAM). Tension and combined tension-torsion experiments on single tapes have been continued, from prior preliminary studies, to characterize their critical current behavior and mechanical strength. Additionally, structural finite element analysis was performed on single tapes under tension and combined tension-torsion to investigate the strain dependence of the critical current. The numerical results were compared to the experimental findings for validation. The SuNAM experimental data matched the numerical model very well while the SuperPower tape experienced degradation at lower stress and strain than predicted in the model. The Superpower tape also displayed greater variability in critical current between different samples as compared with the SuNAM tape.

  16. AC power losses in Bi-2223/Ag HTS tapes

    International Nuclear Information System (INIS)

    Savvides, N.; Reilly, D.; Mueller, K.-H.; Herrmann, J.

    1998-01-01

    Full text: We report measurements at 77 K of the transport ac losses of Bi-2223/Ag composite tapes. The investigated tapes vary from single filament to multifilament construction and include both conventional tapes and other conductor shapes with twisted filaments. The self-field ac losses were determined at 77 K and 60 Hz as a function of ac current amplitude (0 - 100 A). We observe different behaviour among tapes depending on their quality and strain history. For 'good' virgin tapes the experimental data are well described by the Norris equations for the dependence of power loss P on the amplitude I m of the transport current. The data of good monofilament tapes are fitted to the Norris equation P ∼ I m n for an elliptical cross section (ie. n = 3) and the data of good multifilament tapes are fitted to the Norris equation for a rectangular strip (ie. n = 4). Many specimens, however, show a range of behaviour with lower values of n. Based on our work on the effect of strain on the dc transport properties of tapes, we carried out detailed investigations of the effect of controlled applied bend strain on the ac loss. Our results show that irreversible damage to superconducting filaments (ie. cracks) cause the ac loss to rise and n to decrease with increasing strain. In addition, applied strains much greater than the irreversible strain limit cause the ac loss to increase by several orders of magnitude and become ohmic in character with n = 2. Theoretical work is in progress to model the observed behaviour

  17. Bean model and ac losses in Bi2Ca2Cu3O10/Ag tapes

    International Nuclear Information System (INIS)

    Suenaga, M.; Chiba, T.; Wiesmann, H.J.; Haldar, P.

    1997-01-01

    The Bean model is almost solely used to interpret ac losses in the powder-in-tube processed composite conductor, Bi 2 Sr 2 Ca 2 Cu 3 O 10 /Ag. In order to examine the limits of the applicability of the model, a detailed comparison was made between the values of critical current density J c for Bi(2223)/Ag tapes which were determined by standard four-probe-dc measurement, and which were deduced from the field dependence of the ac losses utilizing the model. A significant inconsistency between these values of J c were found, particularly at high fields. Possible sources of the discrepancies are discussed

  18. Calculation of alternating current losses in stacks and coils made of second generation high temperature superconducting tapes for large scale applications

    DEFF Research Database (Denmark)

    Zermeno, Victor M. R.; Abrahamsen, Asger Bech; Mijatovic, Nenad

    2013-01-01

    A homogenization method to model a stack of second generation High Temperature Superconducting tapes under AC applied transport current or magnetic field has been obtained. The idea is to find an anisotropic bulk equivalent for the stack such that the geometrical layout of the internal alternatin...

  19. Data analysis of event tape and connection

    International Nuclear Information System (INIS)

    Gong Huili

    1995-01-01

    The data analysis on the VAX-11/780 computer is briefly described, the data is from the recorded event tape of JUHU data acquisition system on the PDP-11/44 computer. The connection of the recorded event tapes of the XSYS data acquisition system on VAX computer is also introduced

  20. Transobturator tapes are preferable over transvaginal tapes for the management of female stress urinary incontinence: Against

    Directory of Open Access Journals (Sweden)

    Arun Chawla

    2009-01-01

    Full Text Available Midurethral placement of tension-free vaginal tapes with a transvaginal route for stress urinary incontinence achieves higher and better long-term success rates than the transobturator route. Bladder perforations are reported more in transvaginal tape (TVT but incidences of vaginal erosions, extrusion, and groin pain are exceedingly more in TOT groups. There is no clear evidence that transobturator tape (TOT is associated with less post-operative voiding problems than TVT. Major complications such as bowel injuries and significant vascular injuries with TVT are rare. TVT has been found to be superior to TOT and preferable in technically demanding conditions such as prior anti-incontinence operation failures, obese women, and very elevated and scarred lateral cul-de sac. TVT is always preferred in severe grades of stress urinary incontinence and with patients of intrinsic sphincter deficiency (ISD with little or no urethral mobility.

  1. Pulsed transport critical currents of Bi2212 tapes in pulsed magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Rogacki, K [Institute of Low Temperature and Structure Research, Polish Academy of Sciences, Wroclaw (Poland); Gilewski, A; Klamut, J [International Laboratory of High Magnetic Fields and Low Temperatures, Polish Academy of Sciences, Wroclaw (Poland); Newson, M; Jones, H [Clarendon Laboratory, University of Oxford, Oxford (United Kingdom); Glowacki, B A [IRC in Superconductivity and Department of Materials Science, University of Cambridge, Cambridge (United Kingdom)

    2002-07-01

    If high-T{sub C} superconductors are ever to be used in high-field applications, it is vital that the critical surfaces can be mapped under high-field conditions. However, the latest superconductors have high currents even at fields over 20 T, making accurate measurements very difficult due to the thermal and mechanical problems. In this paper, we compare measurements on BSCCO-2212 tape using a number of different methods, particularly an innovative pulsed transport current and pulsed field mode. We show how the analysis of the voltage signal from BSCCO-2212 tape in pulsed conditions may be used to extract the critical current in quasi-stationary conditions. The effect of a metallic substrate on the results is also briefly discussed. (author)

  2. The influence of the roll diameter in flat rolling of of superconducting in situ and ex situ MgB2 tape

    DEFF Research Database (Denmark)

    Hancock, Michael Halloway; Bay, Niels

    2007-01-01

    , 150 and 210 mm in each step. The investigation has shown that the in situ powder is more readily compacted than the ex situ powder, with an average increase of relative density after mechanical processing of 37% for in situ powder and 19% for ex situ powder. Statistical analysis showed that the choice......Applying the powder in tube (PIT) method, single-filament MgB2/Fe wire and tape has been manufactured applying both the ex situ and the in situ approach. The influence of the roll diameter in three-step flat rolling on the powder density and critical temperature has been examined using rolls of 70...... roll in the first and second reductions followed by the 150 mm or 210 mm roll in the last reduction was the optimum strategy for both powder types. AC susceptibility testing showed that for the in situ tapes there was no correlation between the powder density and the critical temperature. For ex situ...

  3. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    International Nuclear Information System (INIS)

    Takayasu, Makoto; Chiesa, Luisa

    2015-01-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour. (paper)

  4. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    Science.gov (United States)

    Takayasu, Makoto; Chiesa, Luisa

    2015-12-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour.

  5. Radiographic Outcomes of Postoperative Taping Following Hallux Valgus Correction.

    Science.gov (United States)

    Ponzio, Danielle Y; Pedowitz, David I; Verma, Kushagra; Maltenfort, Mitchell G; Winters, Brian S; Raikin, Steven M

    2015-07-01

    Traditionally, hallux valgus operative correction has been accompanied by serial spica taping of the great toe during the postoperative period. We retrospectively reviewed 187 adult patients who underwent proximal first metatarsal osteotomy with a modified McBride procedure in 2008-2009 (n = 83) and 2011-2012 (n = 104). Postoperatively, to maintain the corrected position of the hallux, patients from 2008 through 2009 underwent weekly spica taping, while patients from 2011 through 2012 utilized a toe separator. The hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured using anteroposterior weight-bearing preoperative, 2-week postoperative non-weight-bearing, and 3-month weight-bearing final follow-up radiographs. A mixed-effects linear regression model identified differences between the treatment groups over time, and a t test compared actual radiographic differences at final follow-up. The mixed-effects model revealed no significant difference in the HVA over time when comparing patients taped to those not taped at the preoperative (33 ± 6 vs 33 ± 6), 2-week postoperative (10 ± 7 vs 9 ± 6), and 3-month follow-up (14 ± 6 vs 11 ± 7) visits (P = .08). At final follow-up, the HVA was lower for the group that was not taped, but the difference (2.5 degrees) was below the minimal clinically important difference (MCID) (P = .015, 95% CI 0.5-4.5). For IMA, there was improved maintenance of correction over time in the patients that were not taped compared to those taped at the preoperative (15 ± 3 vs 15 ± 3), 2-week postoperative (2 ± 2 vs 3 ± 3), and 3-month follow-up (5 ± 4 vs 7 ± 4) visits (P = .002). At final follow-up, the IMA was lower for the group that was not taped, but the difference (1.7 degrees) was below the MCID (P = .004, 95% CI 0.7-2.9). We report no radiographic benefit of postoperative taping after hallux valgus correction. The present study challenges the previous dogma of postoperative spica taping as the protocol is cost and

  6. Device measures static friction of magnetic tape

    Science.gov (United States)

    Cole, P. T.

    1967-01-01

    Device measures the coefficient of static friction of magnetic tape over a range of temperatures and relative humidities. It uses a strain gage to measure the force of friction between a reference surface and the tape drawn at a constant velocity of approximately 0.0001 inch per second relative to the reference surface.

  7. In-plane aligned YBCO film on textured YSZ buffer layer deposited on NiCr alloy tape by laser ablation with only O+ ion beam assistance

    International Nuclear Information System (INIS)

    Xin Tang Huang

    2000-01-01

    High critical current density and in-plane aligned YBa 2 Cu 3 O 7-x (YBCO) film on a textured yttria-stabilized zirconia (YSZ) buffer layer deposited on NiCr alloy (Hastelloy c-275) tape by laser ablation with only O + ion beam assistance was fabricated. The values of the x-ray phi-scan full width at half-maximum (FWHM) for YSZ(202) and YBCO(103) are 18 deg. and 11 deg., respectively. The critical current density of YBCO film is 7.9 x 105 A cm -2 at liquid nitrogen temperature and zero field, and its critical temperature is 90 K. (author)

  8. Simulation and analysis of tape spring for deployed space structures

    Science.gov (United States)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  9. Test results of fault current limiter using YBCO tapes with shunt protection

    Energy Technology Data Exchange (ETDEWEB)

    Baldan, Carlos A; Lamas, Jerika S; Shigue, Carlos Y [Escola de Engenharia de Lorena, EEL USP, Lorena - SP (Brazil); Filho, Ernesto Ruppert, E-mail: cabaldan@gmail.co [Faculdade de Engenharia Eletrica, FEEC Unicamp, Campinas - SP (Brazil)

    2010-06-01

    A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper.

  10. Study on niobium carbide dispersed superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Wada, H; Tachikawa, K [National Research Inst. for Metals, Tokyo (Japan); Oh' asa, M [Science Univ. of Tokyo (Japan)

    1977-11-01

    Niobium carbide (NbC) dispersed superconducting tapes have been fabricated by two metallurgical processes. In the first process, Ni-Nb-C alloys are directly arc melted and hot worked in air and the NbC phase is distributed in the form of fine discrete particles. In the second process, Ni-Nb and Ni-Nb-Cu alloys are arc melted, hot worked and subjected to solid-state carburization. NbC then precipitates along the grain boundaries, forming a network. The highest superconducting transition temperature attained is about 11 K. Taken together with the lattice parameter measurement, this indicates that NbC with a nearly perfect NaCl structure is formed in both processes. Measured values of the upper critical field, the critical current density and the volume fraction of the NbC phase are also discussed.

  11. Buffer layers grown by replicating the texture of an original template tape

    International Nuclear Information System (INIS)

    Lim, Sunme; Yoo, Jaeun; Park, Chan; Youm, Dojun

    2007-01-01

    We propose a fabrication method of the buffer layers, whose biaxial textures are replicated from an original template tape. The purpose of this method is economical texturing process for coated conductors. At first we prepared a biaxially textured metal tape (TM-tape). Then a sacrifice layer (SA), a buffer layer (BU) and a thick metallic layer (SM) were sequentially deposited on the TM-tape. SA-layer and BU-layer were deposited epitaxially to copy the texture of the TM-tape. SA-layer was dissoluble in water. SM-layer with the textured BU-layer was separated and could be used for a supporting tape for the further growth of a superconducting layer. In this way, it is possible to reuse the original textured TM-tape many times. In this paper, we report the results of our experiments, in which we used a biaxially Ni tape, BaO film, STO film, and a thick Ag film for TM-tape, SA-layer, BU-layer, and SM-layer, respectively. The Ag/STO layers were successfully separated form the Ni tape by dissolving the BaO layer in water. The texture quality of the STO layer was well secured after the separation

  12. Overcurrent experiments on HTS tape and cable conductor

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Jensen, Kim Høj; Træholt, Chresten

    2001-01-01

    their critical current. In this light, it is important to investigate the response of HTS tapes and cable conductors to overcurrents several times the critical current. A number of experiments have been performed on HTS tapes and cable conductors, with currents up to 20 times the critical current. During...... overcurrent experiments, the voltage, and the temperature were measured as functions of time in order to investigate the dynamic behavior of the HTS tape and cable conductor. After each experiment, damage to the superconductors was assessed by measuring the critical current. Preliminary results show...... that within seconds an HTS tape (critical current=17 A) heats above room temperature with an overcurrent larger than 140 A. Similar overcurrent experiments showed that a HTS cable conductor could sustain damage with overcurrents exceeding 10 times the critical current of the cable conductor....

  13. Superconducting flat tape cable magnet

    Science.gov (United States)

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  14. Methods of Measuring Stress Relaxation in Composite Tape Springs

    Science.gov (United States)

    2015-03-26

    10 3. Cure Cycle Recommended for Patz F7 Prepreg . . . . . . . . . . . . . . . . . . . . . 17 4. Typical Stress...unique and dimensionally complex parts. Hand lay-up is the method by which prepreg tape or fibers are laid down and then the matrix is then ‘painted’ on...structure. Hand lay-up using a prepreg tape stands out as the inexpensive choice for the unique low number production of tape springs and should

  15. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    Science.gov (United States)

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  16. Ankle taping does not impair performance in jump or balance tests.

    Science.gov (United States)

    Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.

  17. Pediatric Tape: Accuracy and Medication Delivery in the National Park Service

    Directory of Open Access Journals (Sweden)

    Danielle D. Campagne

    2015-10-01

    Full Text Available Introduction: The objective is to evaluate the accuracy of medication dosing and the time to medication administration in the prehospital setting using a novel length-based pediatric emergency resuscitation tape. Methods: This study was a two-period, two-treatment crossover trial using simulated pediatric patients in the prehospital setting. Each participant was presented with two emergent scenarios; participants were randomized to which case they encountered first, and to which case used the National Park Service (NPS emergency medical services (EMS length-based pediatric emergency resuscitation tape. In the control (without tape case, providers used standard methods to determine medication dosing (e.g. asking parents to estimate the patient’s weight; in the intervention (with tape case, they used the NPS EMS length-based pediatric emergency resuscitation tape. Each scenario required dosing two medications (Case 1 [febrile seizure] required midazolam and acetaminophen; Case 2 [anaphylactic reaction] required epinephrine and diphenhydramine. Twenty NPS EMS providers, trained at the Parkmedic/Advanced Emergency Medical Technician level, served as study participants. Results: The only medication errors that occurred were in the control (no tape group (without tape: 5 vs. with tape: 0, p=0.024. Time to determination of medication dose was significantly shorter in the intervention (with tape group than the control (without tape group, for three of the four medications used. In case 1, time to both midazolam and acetaminophen was significantly faster in the intervention (with tape group (midazolam: 8.3 vs. 28.9 seconds, p=0.005; acetaminophen: 28.6 seconds vs. 50.6 seconds, p=0.036. In case 2, time to epinephrine did not differ (23.3 seconds vs. 22.9 seconds, p=0.96, while time to diphenhydramine was significantly shorter in the intervention (with tape group (13 seconds vs. 37.5 seconds, p<0.05. Conclusion: Use of a length-based pediatric emergency

  18. Simulation of YBCO Tape and Coils in HTS Maglev System

    Directory of Open Access Journals (Sweden)

    Song Mengxiao

    2017-01-01

    Full Text Available In the process of running high temperature superconducting maglev train, the AC(Alternating Current loss of superconducting coil is directly related to its safe operation and operating cost. In this paper, the simulation model was built based on the finite element software COMSOL Multiphysics, and mainly simulated and calculated the AC losses of YBCO(Yttrium Barium Copper Oxide tape and coils. In this model, as the solving object, the singular and infinite long YBCO tape and coils model was solved with H-formulation and the nonlinear characteristic (E-J constitutive law and anisotrophy (B-J characteristic were taken into consideration as the theoretical foundation. Then on the basis of the model under maglev suspension system, AC losses under different amplitude and frequence AC currents were calculated. The results shows that under different frequencies and dynamic components, the local maximum AC loss of YBCO tape and coils occurs when the steady-state DC(Direct Current current is 30A. Then comparing with old maglev suspension system, the new system can greatly reduce the energy consumption and the material cost.

  19. Experiments and FE modeling of stress-strain state in ReBCO tape under tensile, torsional and transverse load

    NARCIS (Netherlands)

    Ilin, K.; Ilin, K.; Yagotyntsev, Kostyantyn; Zhou, Chao; Gao, Peng; Kosse, Jaap Jeroen; Otten, S.J.; Wessel, Wilhelm A.J.; Haugan, T.J.; van der Laan, D.C.; Nijhuis, Arend

    2015-01-01

    For high current superconductors in high magnet fields with currents in the order of 50 kA, single ReBCO coated conductors must be assembled in a cable. The geometry of such a cable is mostly such that combined torsion, axial and transverse loading states are anticipated in the tapes and tape

  20. Non-contact inline monitoring of thermoplastic CFRP tape quality using air-coupled ultrasound

    Science.gov (United States)

    Essig, W.; Fey, P.; Meiler, S.; Kreutzbruck, M.

    2017-02-01

    Beginning with the aerospace industry, fiber reinforced plastics have spread towards many applications such as automotive, civil engineering as well as sports and leisure articles. Their superior strength and stiffness to mass ratio made them the number one material for achieving high performance. Especially continuous fiber reinforced plastics allow for the construction of structures which are custom tailored to their mechanical loads by adjusting the paths of the fibers to the loading direction. The two main constituents of CFRP are carbon fibers and matrix. Two possibilities for matrix material exist: thermosetting and thermoplastic matrix. While thermosetting matrix may yield better properties with respect to thermal loads, thermoplasticity opens a wide range of applications due to weldability, shapeability, and compatibility to e.g. injection molded thermoplastic materials. Thin (0.1 mm) thermoplastic continuous fiber CFRP tapes with a width of 100 mm were examined using air-coupled ultrasound. Transducers were arranged in reflection as well as transmission setup. By slanted incidence of the ultrasound on the tape surface, guided waves were excited in the material in fiber direction and perpendicular to the fiber direction. Artificial defects - fiber cuts, matrix cuts, circular holes, low velocity impacts from tool drop, and sharp bends - were produced. Experiments on a stationary tape showed good detectability of all artificial defects by guided waves. Also the effects of variation in material properties, fiber volume content and fiber matrix adhesion being the most relevant, on guided wave propagation were examined, to allow for quality assessment. Guided wave measurements were supported by destructive analysis. Also an apparatus containing one endless loop of CFRP tape was constructed and built to simulate inline testing of CFRP tapes, as it would be employed in a CFRP tape production environment or at a CFRP tape processing facility. The influences of tape

  1. Delamination behaviour in differently copper laminated REBCO coated conductor tapes under transverse loading

    Energy Technology Data Exchange (ETDEWEB)

    Gorospe, Alking [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Department of Engineering, Aurora State College of Technology, Baler Aurora 3200 (Philippines); Nisay, Arman [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Shin, Hyung-Seop, E-mail: hsshin@andong.ac.kr [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of)

    2014-09-15

    Highlights: • I{sub c} degradation behavior under transverse tension loading in different CC tape structure. • Weibull distribution analysis applied on delamination mechanism of CC tape. • Delamination mechanism on CC tapes depending on copper lamination type. • SEM and WDS mapping analysis of delamination sites under transverse loading. - Abstract: Laminated HTS coated conductor (CC) tapes having a unique multi-layer structure made them vulnerable when exposed to transverse loading. Electromechanical transport properties of these CC tapes can be affected by excessive transverse stresses. Due to the coefficient of thermal expansion (CTE) mismatch and incompatibility among constituent materials used in coil applications, delamination among layers occurs and causes critical current, I{sub c} degradation in the CC tapes. In this study, the delamination behaviors in copper (Cu) solder-laminated CC tapes by soldering and surround Cu-stabilized ones by electroplating under transverse tension loading were investigated. Similarly to the surround Cu-stabilized CC tapes in our previous reports, the Cu solder-laminated CC tapes also showed an abrupt and gradual I{sub c} degradation behavior. However, the Cu solder-laminated CC tapes showed different delamination morphologies as compared to the surround Cu-stabilized CC tapes; the superconducting side and the substrate side of the Cu solder laminated CC tapes were totally separated by delamination. On the other hand, the brass laminate did not show any significant effect on the delamination strength when it is added upon the surround Cu-stabilized CC tapes.

  2. Adhesive tape exfoliation

    DEFF Research Database (Denmark)

    Bohr, Jakob

    2015-01-01

    Single-crystal graphite can be cleaved by the use of an adhesive tape. This was also the initial route for obtaining graphene, a one-layer thick graphite slab. In this letter a few simple and fun considerations are presented in an attempt to shed some light on why this procedure is successful...

  3. Kinesio® Tape Barrier Does Not Inhibit Intramuscular Cooling During Cryotherapy.

    Science.gov (United States)

    Lyman, Katie J; McCrone, Michael; Hanson, Thomas A; Mellinger, Christopher D; Gange, Kara

    2018-05-29

    Allied health care professionals commonly apply cryotherapy as treatment for acute musculoskeletal trauma and the associated symptoms. Understanding the impact of a tape barrier on intramuscular temperature can assist in determining treatment duration for effective cryotherapy. To determine whether Kinesio® Tape acts as a barrier that affects intramuscular temperature during cryotherapy application. A repeated-measures, counterbalanced design in which the independent variable was tape application and the dependent variable was muscle temperature as measured by thermocouples placed 1 cm beneath the adipose layer. Additional covariates for robustness were BMI and adipose thickness. University research laboratory. 19 male college students with no contraindications to cryotherapy, no known sensitivity to Kinesio® Tape, and no reported quadriceps injury within the past six months. Topical cryotherapy: crushed-ice bags of 1 kg and 0.5 kg. Intramuscular temperature. The tape barrier had no statistically significant effect on muscle temperature. The pattern of temperature change was indistinguishable between participants with and without tape application. Findings suggest health care professionals can combine cryotherapy with a Kinesio® Tape application without any need for adjustments to cryotherapy duration.

  4. 10 years of 1:1 taping in Belgium - A selection of murder cases involving fibre examination.

    Science.gov (United States)

    De Wael, K; Lepot, L; Lunstroot, K; Gason, F

    2016-01-01

    Since 2002, the 1:1 tape lifting technique on murder victims has been introduced in Belgium. Thirty-six murder cases for which a fibre examination was carried out in our laboratory between 2002 and 2012 are reviewed. These cases all involved the collection of microtraces on 39 victims using a 1:1 taping or similar technique, called semi 1:1 taping. The degree of "positive outcomes" for investigative and comparative fibre cases is high. Especially in cases where the modus operandi of suspects had to be verified, the examination of the 1:1 tape lifting led to very useful fibre results. The findings from some of these fibre cases are used to illustrate the advantages, drawbacks and points of interest of the two collection techniques. These are also compared with the zonal taping technique, another microtrace collection technique applied on victims at the crime scene. Copyright © 2015 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Enhancement of turbulent flow heat transfer in a tube with modified twisted tapes

    Energy Technology Data Exchange (ETDEWEB)

    Lei, Y.G.; Zhao, C.H.; Song, C.F. [College of Environmental Science and Engineering, Taiyuan University of Technology, Taiyuan (China)

    2012-12-15

    Numerical simulations were performed to study the fluid flow and heat transfer in a tube with staggered twisted tapes with central holes. In the range of Reynolds numbers between 6000 and 28 000, the modified twisted tapes increased the Nusselt number by 76.2 {proportional_to} 149.7 % and the friction factor by 380.2 {proportional_to} 443.8 % compared to the smooth tube. Compared to the typical twisted tapes, the modified twisted tapes produced an acceleration flow through the triangle regions leading to the enhancement of heat transfer, and the holes in the modified tapes reduced the severe pressure loss. It was found that the modified twisted tapes decreased the friction factor by 8.0 {proportional_to} 16.1 % and enhanced the heat transfer by 34.1 {proportional_to} 46.8 % in comparison with the typical tapes. These results indicated that the performance ratio values of the tube with modified twisted tapes were higher than 1.0 in the range of Reynolds numbers studied. The computed performance ratios of the tube with modified twisted tapes were much higher than those of the tube with typical twisted tapes. This means that the integrated performance of the tube with staggered twisted tapes with central holes is superior to that of the tube with typical twisted tapes. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Molten carbonate fuel cell integral matrix tape and bubble barrier

    International Nuclear Information System (INIS)

    Reiser, C.A.; Maricle, D.L.

    1983-01-01

    A molten carbonate fuel cell matrix material is described made up of a matrix tape portion and a bubble barrier portion. The matrix tape portion comprises particles inert to molten carbonate electrolyte, ceramic particles and a polymeric binder, the matrix tape being flexible, pliable and having rubber-like compliance at room temperature. The bubble barrier is a solid material having fine porosity preferably being bonded to the matrix tape. In operation in a fuel cell, the polymer binder burns off leaving the matrix and bubble barrier providing superior sealing, stability and performance properties to the fuel cell stack

  7. SUPLEMENTASI Lactobacillus acidophilus SNP-2 PADA TAPE DAN PENGARUHNYA PADA RELAWAN [Supplementation of Lactocbacillus acidophilus SNP-2 Into Tape and its Effect to the Volunteer

    Directory of Open Access Journals (Sweden)

    Endang S Rahayu1

    2004-08-01

    Full Text Available Functional food is defined as any potentially healthful food or food ingredient that may provide a health benefit beyond the traditional nutrients it contains. Many researches have been conducted on the health benefit of probiotic (life bacterial cells, one of the ingredient of functional foods. One of the potential bacteria used for probiotic agent and also involved in traditional fermented foods are lactic acid bacteria (LAB. Previous research showed that Lactobacillus acidophilus SNP-2 isolated from faecal material of healthy infant is resistant to acid and bile salt, and has an antagonistic effect against several enteric bacterial pathogens. The objective of this research was to study the effect of L. acidophilus SNP-2 as probiotic agent to the health benefits. These bacteria were supplemented into tape ketan (fermented sticky rice, the indigenous Indonesian fermented food. Tape ketan was chosen as the carrier of probiotic biomass based on the high population of LAB in this product, i.e., 1.3 x 108 CFU/g. Addition of L. acidophilus SNP-2 biomass prior to fermentation of tape ketan resulted in a higher total of LAB cells, i.e. 2.1 x 109 CFU/g compared to the amount of 1.5 x 108 CFU/g when the addition was done after fermentation. Consumption of tape ketan containing probiotic agent by the volunteers increased the population of lactobacilli (from 1.7x107 CFU/g to 9.9x107 CFU/g and decreased the population of enterobacteriacea (from 5.4x109 CFU/g to 4.4x108 in their faecal material. This phenomenon revealed that probiotic agent was able to colonize and inhibit the growth of enterobacteriaceae in the gastrointestinal tract. The result implied that tape ketan can be used as a carrier for probiotic agent and it can be categorized as functional food

  8. Simulation of magnetization and levitation characteristics of HTS tape stacks

    Science.gov (United States)

    Anischenko, I. V.; Pokrovskii, S. V.; Mineev, N. A.

    2017-12-01

    In this work it is presented a computational model of a magnetic levitation system based on stacks of high-temperature second generation superconducting tapes (HTS) GdBa2Cu3O7-x. Calculated magnetic field and the current distributions in the system for different stacks geometries in the zero-field cooling mode are also presented. The magnetization curves of the stacks in the external field of a permanent NdFeB magnet and the levitation force dependence on the gap between the magnet and the HTS tapes stack were obtained. A model of the magnetic system, oriented to levitation application, is given. Results of modeling were compared with the experimental data.

  9. Experimental and numerical study of influence of ferromagnetic cover on critical current of BiSCCO-2223/Ag tape superconductor

    International Nuclear Information System (INIS)

    Vojenciak, M; Souc, J; Goemoery, F

    2009-01-01

    Samples of commercially available BiSCCO-2223/Ag tape have been partially covered by the ferromagnetic material. Improvement of the self-field critical current up to 15 % has been achieved by this procedure. A critical current of such tape strongly depends on geometric and magnetic properties of both, the superconducting tape as well as the ferromagnetic cover. Numerical simulations, based on the critical state model using commercial finite element method (FEM) code, have been performed. Properties of superconductor are characterized by anisotropic dependence of the critical current density on magnetic field as well as detail geometry of filaments. The ferromagnetic material is characterized by nonlinear magnetization curve. Nonlinear dependences of the critical current on selected parameters are shown in this work. Optimization of the cover parameters using these curves has been made. Samples with various parameters have been manufactured for the confirmation of numerical simulations results. Experimental results are in good qualitative agreement with results obtained by numerical simulations.

  10. Increase of horizontal stiffness for fixing mobile machine with vacuum pad by using filament tapes

    Science.gov (United States)

    Kim, H.-S.; Park, J.-K.; Ro, S.-K.

    2017-08-01

    This paper presents a method to increase fixing stiffness of mobile machine by using filament tapes. Mobile machine moves on a large workpiece for cutting, drilling, welding, and cleaning, etc., so for those works. The vacuum pads are generally used for attaching or detaching objects frequently. Of course, if the object is a metal body, the magnetic force can be used. The vacuum pads have an advantage that it can be used regardless of the magnetic property of the object, but it has a disadvantage that the fixing stiffness is not strong because the material is rubber. That’s why it is difficult to maintain the accurate position of the mobile machine as it could be shaken when being moved or fixed. Thus, this study proposed a method to increase the horizontal fixing stiffness of the mobile machine by using filament tapes to the side of the vacuum pads which compensate the shortcoming of the vacuum pads. Filament tapes are made by inserting special material filaments which have high rigidity into an existing tape to increase tensile strength. In the configuration of the proposed method, the vacuum pad forms the vertical fixing stiffness by suction force, and the filament tape forms the horizontal fixing stiffness by adhesive force. In order to verify the effectiveness of the proposed method, the experimental equipment to measure the fixing stiffness was fabricated, and the comparison experiment was carried out. First, the horizontal fixing stiffness of the vacuum pads and the filament tape was measured respectively as a baseline data, and then the same measurement of the combination of them was performed for the comparison. In addition, another experiment for comparison between Gecko films and filament tape was performed. The results showed that the horizontal fixing stiffness was significantly increased when the filament tape was used together with the vacuum pads, and the Gecko film was not as much effective as the filament tape in terms of the strength of the

  11. Effects of kinesio taping and hot packs on premenstrual syndrome in females.

    Science.gov (United States)

    Choi, Jung-Hyun

    2017-09-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome.

  12. An automated magnetic tape vault at CERN computer center

    CERN Multimedia

    Claudia Marcelloni

    2008-01-01

    The rapidly changing data processing landscape the underlying long-term storage technology remains the tried and tested magnetic tape. This robust and mature technology is used to store the complete LHC data set, from which a fraction of the data is copied to overlying disk caches for fast and widespread access. The handling of the magnetic tape cartridges is now fully automated, as they are racked in vaults where they are moved between the storage shelves and the tape drives by robotic arms.

  13. Study on the optimum design of a high temperature superconducting coil

    International Nuclear Information System (INIS)

    Ishiguri, Shinichi; Yamaguchi, Mitsugi; Fukui, Satoshi; Ogawa, Jun; Sato, Takao

    2005-01-01

    It is in particular of importance for HTS coils to secure a larger central magnetic field, a large stored energy, etc. with shorter length of HTS tapes. The critical current of an HTS tape depends on both the flux density and the flux angle with respect to tapes. In view of this, the performance improvement of HTS coils is taken into account with an analytical model. As a coil shape, the minimum volume coil derived from the Fabry Factor constant curve is taken up, which is often employed at low temperature coils. The electric field distribution within a coil cross-section is calculated to examine effects on a current carrying capability. It is clear that high electric field portions appear at the coil edge region due primarily to inclined magnetic fluxes against HTS tapes. Considering this, a grade winding method of a coil is proposed, where the winding density of conductors is reduced at coil edge portions. With this coil winding structure, the critical current of an HTS coil is improved since the magnetic field is reduced at edge portions. The stored energy per HTS tape length and the central magnetic field of the coil can be remarkably increased by this kind of grade winding method

  14. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    OpenAIRE

    Brendon A. Parsons; Olivia Lin Smith; Myeong Chae; Veljko Dragojlovic

    2015-01-01

    Summary In a PTFE tape phase-vanishing reaction (PV-PTFE), a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better...

  15. A new method of measurement of tension on a moving magnetic tape

    Science.gov (United States)

    Kurtinaytis, A. K.; Lauzhinskas, Y. S.

    1973-01-01

    The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

  16. [Efficacy of the application of kinesio tape in patients with stroke].

    Science.gov (United States)

    Ortiz-Ramirez, J; Perez-De la Cruz, S

    2017-02-16

    To review the effects achieved by the kinesio tape in patients with stroke in scientific studies published on date and to discuss these findings may be of interest to neurology. An exhaustive search in the main scientific databases using keywords such as kinesio tape, kinesiotaping, musculoskeletal tape, taping medical concept was carried out. Citations of selected articles and scientific papers published on the website of the Spanish Association of Neuromuscular Bandage were analyzed. Experimental, quasi-experimental, clinical trials and case studies published were used, without limit date, with therapeutical treatment purpose provide important results. Eight articles have met the inclusion criteria. There are eight studies that examine the effect on kinesio tape on lower limb, gait and balance in this kind of therapy, even upper limb and swallowing problems that these patients could present. The kinesio tape in neurological patients can be a complementary technique that empirically provides benefits. However, better methodological quality studies demonstrating the effects attributed to him are still needed.

  17. Importing low-density ideas to high-density revitalisation

    DEFF Research Database (Denmark)

    Arnholtz, Jens; Ibsen, Christian Lyhne; Ibsen, Flemming

    2016-01-01

    Why did union officials from a high-union-density country like Denmark choose to import an organising strategy from low-density countries such as the US and the UK? Drawing on in-depth interviews with key union officials and internal documents, the authors of this article argue two key points. Fi...

  18. Recovery of recordings from heat damaged magnetic tapes

    Science.gov (United States)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  19. A 5.9 tesla conduction-cooled coil composed of a stack of four single pancakes wound with YBCO wide tapes

    Energy Technology Data Exchange (ETDEWEB)

    Iwai, Sadanori, E-mail: sadanori.iwai@toshiba.co.jp; Miyazaki, Hiroshi; Tosaka, Taizo; Tasaki, Kenji; Urata, Masami; Ioka, Shigeru; Ishii, Yusuke

    2013-11-15

    Highlights: •We made a coil composed of a stack of four single pancakes wound with YBCO wide tapes. •The coil had a central magnetic field as high as 5.9 T at 20 K. •The effect of the tape width on the central magnetic field was small near coil I{sub c}. •We confirmed that performance of YBCO coil was improved by using wider tape. -- Abstract: We have been developing a conduction-cooled coil wound with YBCO-coated conductors for HTS applications. Previously, we have fabricated a coil composed of a stack of 12 single pancakes wound with 4 mm-wide YBCO tapes. This coil had a central magnetic field as high as 5.1 T at 10 K under conduction-cooled conditions. In the present study, we fabricated and tested a coil composed of a stack of four single pancakes wound with 12 mm-wide YBCO tapes. The total size of the coil and the J{sub c} value of the tapes were almost the same as those of the former coil. At 77 K, the voltage–current characteristics showed a high n-value of 24, confirming that the coil had no degradation. Furthermore, in a conduction-cooled configuration at 20 K to 60 K, the coil showed a high n-value of over 20. At 20 K, the central magnetic field reached 5.9 T at 903 A, which is 1.3-times higher than that of the former coil.

  20. How PE tape performs under concrete coating

    International Nuclear Information System (INIS)

    Dritt, H.J.

    1984-01-01

    The program objectives were to evaluate the performance of polyethylene tape plant coating and fusion bonded epoxy powder systems with particular respect to the following: 1. Concrete coating application procedures; 2. The shear resistance during laying and retrieving operations of the coating at the various interfaces (a) Pipe and anti-corrosion coating; (b) Anti-corrosion coating and outerwrap; (c) Overlap areas of the anti-corrosion and outerwrap layers; (d) Between concrete and the various corrosion coatings during laying and retrieving operations. 3. Resistance to damage of the coating as a consequence of cracking or slippage of the concrete weight coating. 4. Ability of various coatings to withstand the damage during concrete application by both impact and compression methods; 5. Evaluation of tape and shrink sleeve joint coatings at the cut-back area as well as performance of tape under hot asphalt coating

  1. Outcome of transvaginal mesh and tape removed for pain only.

    Science.gov (United States)

    Hou, Jack C; Alhalabi, Feras; Lemack, Gary E; Zimmern, Philippe E

    2014-09-01

    Because there is reluctance to operate for pain, we evaluated midterm outcomes of vaginal mesh and synthetic suburethral tape removed for pain as the only indication. After receiving institutional review board approval we reviewed a prospective database of women without a neurogenic condition who underwent surgery for vaginal mesh or suburethral tape removal with a focus on pain as the single reason for removal and a minimum 6-month followup. The primary outcome was pain level assessed by a visual analog scale (range 0 to 10) at baseline and at each subsequent visit with the score at the last visit used for analysis. Parameters evaluated included demographics, mean time to presentation and type of mesh or tape inserted. From 2005 to 2013, 123 patients underwent surgical removal of mesh (69) and suburethral tape (54) with pain as the only indication. Mean followup was 35 months (range 6 to 59) in the tape group and 22 months (range 6 to 47) in the mesh group. The visual analog scale score decreased from a mean preoperative level of 7.9 to 0.9 postoperatively (p = 0.0014) in the mesh group and from 5.3 to 1.5 (p = 0.00074) in the tape group. Pain-free status, considered a score of 0, was achieved in 81% of tape and 67% of mesh cases, respectively. No statistically significant difference was found between the groups. When pain is the only indication for suburethral tape or vaginal mesh removal, a significant decrease in the pain score can be durably expected after removal in most patients at midterm followup. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    Directory of Open Access Journals (Sweden)

    Brendon A. Parsons

    2015-06-01

    Full Text Available In a PTFE tape phase-vanishing reaction (PV-PTFE, a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better describe the process of solvent transport in PV-PTFE bromination reactions. Though PTFE tape has been reported as impermeable to some compounds, such as dimethyl phthalate, solvent adsorption to the tape altered its permeability and allowed diffusion through channels of solvent within the PTFE tape. In this case, the solvent-filled pores of the PTFE tape are chemically more akin to the adsorbed solvent rather than to the PTFE fluorous structure. The solvent uptake effect, which was frequently observed in the course of PV-PTFE reactions, can be related to the surface tension of the solvent and the polarity of the solvent relative to the reagent. The lack of pores in bulk PTFE prevents solvents from altering its permeability and, therefore, bulk PTFE is impermeable to most solvents and reagents. However, bromine, which is soluble in liquid fluorous media, diffused through the bulk PTFE. A better understanding of the PTFE phase barrier will make it possible to further optimize the PV-PTFE reaction design.

  3. High Energy Density Laboratory Astrophysics

    CERN Document Server

    Lebedev, Sergey V

    2007-01-01

    During the past decade, research teams around the world have developed astrophysics-relevant research utilizing high energy-density facilities such as intense lasers and z-pinches. Every two years, at the International conference on High Energy Density Laboratory Astrophysics, scientists interested in this emerging field discuss the progress in topics covering: - Stellar evolution, stellar envelopes, opacities, radiation transport - Planetary Interiors, high-pressure EOS, dense plasma atomic physics - Supernovae, gamma-ray bursts, exploding systems, strong shocks, turbulent mixing - Supernova remnants, shock processing, radiative shocks - Astrophysical jets, high-Mach-number flows, magnetized radiative jets, magnetic reconnection - Compact object accretion disks, x-ray photoionized plasmas - Ultrastrong fields, particle acceleration, collisionless shocks. These proceedings cover many of the invited and contributed papers presented at the 6th International Conference on High Energy Density Laboratory Astrophys...

  4. Quantitative electron microscopy and spectroscopy of MgB2 wires and tapes

    International Nuclear Information System (INIS)

    Birajdar, B; Peranio, N; Eibl, O

    2008-01-01

    In MgB 2 the correlation of microstructure with superconducting properties, in particular the critical current density, requires powerful analytical tools. Critical current densities and electrical resistivities of different MgB 2 superconductors differ by orders of magnitudes and the current limiting mechanisms have not been fully understood. Granularity of MgB 2 is one significant reason for reduced critical current densities and is introduced intrinsically by the anisotropy of B c2 but also extrinsically by the microstructure of the material. B c2 enhancement by doping is another important challenge for chemical analysis and, at present, doping levels are not well controlled on the sub-μm scale. In this paper the quantitative electron microscopy and spectroscopy methods essential for the microstructural analysis of MgB 2 are described. By quantitative electron microscopy and spectroscopy we mean a combined SEM and TEM analysis that covers various length scales from μm to nm. Contamination-free sample preparation, chemical mapping including B, and advanced chemical quantification using x-ray microanalysis were essential elements of the applied methodology. The methodology was applied to in situ and ex situ MgB 2 wires and tapes with and without SiC additives. Quantitative B analysis by EDX spectroscopy was applied quantitatively in the SEM and TEM, which is a major achievement. Although MgB 2 is a binary system, the thermodynamics of phase formation is complex, and the complexity is dramatically increased if additives like SiC are used. The small, sub-μm grain sizes of the matrix and secondary phases require TEM methods. However, granularity on the μm scale was also identified and underlines the importance of the combined SEM and TEM studies. Significant differences in the microstructure were observed for in situ and ex situ samples. This holds particularly if SiC was added and yielded Mg 2 Si for in situ samples annealed at 600-650 deg. C and Mg-Si-O phases

  5. Generation of ultra-sound during tape peeling

    KAUST Repository

    Marston, Jeremy O.

    2014-03-21

    We investigate the generation of the screeching sound commonly heard during tape peeling using synchronised high-speed video and audio acquisition. We determine the peak frequencies in the audio spectrum and, in addition to a peak frequency at the upper end of the audible range (around 20 kHz), we find an unexpected strong sound with a high-frequency far above the audible range, typically around 50 kHz. Using the corresponding video data, the origins of the key frequencies are confirmed as being due to the substructure "fracture" bands, which we herein observe in both high-speed continuous peeling motions and in the slip phases for stick-slip peeling motions.

  6. Generation of ultra-sound during tape peeling

    KAUST Repository

    Marston, Jeremy O.; Riker, Paul W.; Thoroddsen, Sigurdur T

    2014-01-01

    We investigate the generation of the screeching sound commonly heard during tape peeling using synchronised high-speed video and audio acquisition. We determine the peak frequencies in the audio spectrum and, in addition to a peak frequency at the upper end of the audible range (around 20 kHz), we find an unexpected strong sound with a high-frequency far above the audible range, typically around 50 kHz. Using the corresponding video data, the origins of the key frequencies are confirmed as being due to the substructure "fracture" bands, which we herein observe in both high-speed continuous peeling motions and in the slip phases for stick-slip peeling motions.

  7. Formation of oiliness and sebum output--comparison of a lipid-absorbant and occlusive-tape method with photometry.

    Science.gov (United States)

    Serup, J

    1991-07-01

    Sebum output and the development of oiliness formation were studied in 24 acne-prone volunteers. Sebutape and photometric measurement by the Sebumeter were compared. Tapes were taken 1, 2 and 3 h after degreasing. Tapes were scored, and light transmission was measured by a special densitometric device. Sebumeter recordings were performed after 3 h. Densitometric evaluation of tapes was accurate with a high correlation to scoring. Sebutape and Sebumeter assessments correlated. However, in some individuals the tape method overestimated the sebum output. Right-left comparison indicated that the tape method was less reproducible, particularly after longer sampling periods. It is suggested that Sebutape, due to water occlusion and temperature insulation during the sampling period, interferes with sebum droplet formation and spreading. However, such systematic interference may be advantageous since sweating and heat are important clinical prerequisites in the formation of oiliness. Thus, it is suggested that the Sebutape is a specialized method for the determination of 'oiliness', the very last phase of sebum output, in which sebum droplets spread over the skin surface. The tape is not automatically comparable to other methods for determining sebum output from the follicular reservoir.

  8. Temperature dependence of filament-coupling in Bi-2223 tapes: magneto-optical study

    International Nuclear Information System (INIS)

    Bobyl, A.V.; Shantsev, D.V.; Galperin, Y.M.; Johansen, T.H.; Baziljevich, M.; Gaevski, M.E.

    2000-01-01

    Coupling through random superconducting bridges between filaments in a multifilamentary Ag-sheathed Bi 2 Sr 2 Ca 2 Cu 3 O 10+δ tape has been investigated by magneto-optical imaging at temperatures from 20 K up to T c . Magnetic flux distributions have been measured on the surface of an intact tape in the remanent state on applying a strong perpendicular magnetic field. The flux distributions observed at low temperatures reflect the arrangement of individual filaments. At high temperatures, the distribution becomes more similar to that for a uniform monocore tape, indicating that superconducting connections appear between the filaments. To discuss the relative contributions of the intra- and inter-filament currents, a simple model based on the Bean critical state was proposed and applied to analyse the temperature dependent behaviour. The inter-filament coupling, increasing with temperature, reaches at 77 K a point where the currents flowing in large inter-filament loops are roughly equal to the intra-filament currents. (author)

  9. POSTOPERATIVE URINARY RETENTION AND EARLY REPOSITION OF TENSION-FREE VAGINAL TAPE

    Directory of Open Access Journals (Sweden)

    Marijan Lužnik

    2003-12-01

    Full Text Available Background. The purpose of this article is to show a possible method of treatment of postoperative urinary retention after an initial tension-free vaginal tape.Methods. From December 1999 to May 2003 we performed one hundred TVT procedures at our department, among them five women had postoperative urinary retention evaluated with catheterization. Revision and reposition of tension-free vaginal tape were performed if retention of urine was over 100 ml.Results. Urinary retention after an initial tension-free vaginal tape was successfully treated by early reposition of tension-free vaginal tape. This resulted in immediate residualfree voiding and continence, which remained unchanged at 6 week and 3 month follow-up.Conclusions. Postoperative urinary retention may be treated by reposition instead of dissection or elongation of the tension-free vaginal tape.

  10. White House Tapes of the Nixon Administration, 1971 to 1973

    Data.gov (United States)

    National Archives and Records Administration — This dataset provides information about the Nixon Administration's White House Tapes. The White House Tapes contain sound recordings of President Richard Nixon's...

  11. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an adhesive tape solvent is a device that consists of a liquid such as 1,1,2-trichloro-1,2,2-trifluoroethane...

  12. Accelerated aging studies and environmental stability of prototype tamper tapes

    Energy Technology Data Exchange (ETDEWEB)

    Wright, B.W.; Wright, C.W. [Pacific Northwest Lab., Richland, WA (United States); Bunk, A.R. [Battelle Columbus Lab., OH (United States)] [and others

    1995-05-01

    This report describes the results of accelerated aging experiments (weathering) conducted on prototype tamper tapes bonded to a variety of surface materials. The prototype tamper tapes were based on the patented Confirm{reg_sign} tamper-indicating technology developed and produced by 3M Company. Tamper tapes bonded to surfaces using pressure sensitive adhesive (PSA) and four rapid-set adhesives were evaluated. The configurations of the PSA-bonded tamper tapes were 1.27-cm-wide Confirm{reg_sign} 1700 windows with vinyl underlay and 2.54-cm-wide Confirm{reg_sign} 1700 windows with vinyl and polyester underlays. The configurations of the rapid-set adhesive-bonded tamper tapes were 2.54-cm-wide Confirm{reg_sign} (1700, 1500 with and without primer, and 1300) windows with vinyl underlay. Surfaces used for bonding included aluminum, steel, stainless steel, Kevlar{reg_sign}, brass, copper, fiberglass/resin with and without gel coat, polyurethane-painted steel, acrylonitrile:butadiene:styrene plastic, polyester fiberglass board, Lexan polycarbonate, and cedar wood. Weathering conditions included a QUV cabinet (ultraviolet light at 60{degrees}C, condensing humidity at 40{degrees}C), a thermal cycling cabinet (-18{degrees}C to 46{degrees}C), a Weather-O-Meter (Xenon lamp), and exposure outdoors in Daytona Beach, Florida. Environmental aging exposures lasted from 7 weeks to 5 months. After exposure, the tamper tapes were visually examined and tested for transfer resistance. Tamper tapes were also exposed to a variety of chemical liquids (including organic solvents, acids, bases, and oxidizing liquids) to determine chemical resistance and to sand to determine abrasion resistance.

  13. The evolution of the tape measure protein: units, duplications and losses

    Directory of Open Access Journals (Sweden)

    Poisson Guylaine

    2011-10-01

    Full Text Available Abstract Background A large family of viruses that infect bacteria, called phages, is characterized by long tails used to inject DNA into their victims' cells. The tape measure protein got its name because the length of the corresponding gene is proportional to the length of the phage's tail: a fact shown by actually copying or splicing out parts of DNA in exemplar species. A natural question is whether there exist units for these tape measures, and if different tape measures have different units and lengths. Such units would allow us to retrace the evolution of tape measure proteins using their duplication/loss history. The vast number of sequenced phages genomes allows us to attack this problem with a comparative genomics approach. Results Here we describe a subset of phages whose tape measure proteins contain variable numbers of an 11 amino acids sequence repeat, aligned with sequence similarity, structural properties, and simple arithmetics. This subset provides a unique opportunity for the combinatorial study of phage evolution, without the added uncertainties of multiple alignments, which are trivial in this case, or of protein functions, that are well established. We give a heuristic that reconstructs the duplication history of these sequences, using divergent strains to discriminate between mutations that occurred before and after speciation, or lineage divergence. The heuristic is based on an efficient algorithm that gives an exhaustive enumeration of all possible parsimonious reconstructions of the duplication/speciation history of a single nucleotide. Finally, we present a method that allows, when possible, to discriminate between duplication and loss events. Conclusions Establishing the evolutionary history of viruses is difficult, in part due to extensive recombinations and gene transfers, and high mutation rates that often erase detectable similarity between homologous genes. In this paper, we introduce new tools to address this

  14. High-density multicore fibers

    DEFF Research Database (Denmark)

    Takenaga, K.; Matsuo, S.; Saitoh, K.

    2016-01-01

    High-density single-mode multicore fibers were designed and fabricated. A heterogeneous 30-core fiber realized a low crosstalk of −55 dB. A quasi-single-mode homogeneous 31-core fiber attained the highest core count as a single-mode multicore fiber.......High-density single-mode multicore fibers were designed and fabricated. A heterogeneous 30-core fiber realized a low crosstalk of −55 dB. A quasi-single-mode homogeneous 31-core fiber attained the highest core count as a single-mode multicore fiber....

  15. Red Tape dan Perilaku Masyarakat dalam Pelayanan Izin Usaha Perdagangan di Kota Makassar

    OpenAIRE

    Lukman, Lukman

    2015-01-01

    : Red tape as pathology has long been the focus of an expert study of bureaucracy. Early scholarly attempts conceptualized red tape at the individual level as in Merton's classic thesis (1940) about goal displacement. Waldo (1946) one man's red tape is another man's system. Kaufman (1977) one person's red tape may be another's treasured safeguard. Osborne and Gaebler (1992) good people trapped in bad systems. Bozeman and Feneey (2011) red tape is often used as a synonym of the term procedures...

  16. High-field, high-density tokamak power reactor

    International Nuclear Information System (INIS)

    Cohn, D.R.; Cook, D.L.; Hay, R.D.; Kaplan, D.; Kreischer, K.; Lidskii, L.M.; Stephany, W.; Williams, J.E.C.; Jassby, D.L.; Okabayashi, M.

    1977-11-01

    A conceptual design of a compact (R 0 = 6.0 m) high power density (average P/sub f/ = 7.7 MW/m 3 ) tokamak demonstration power reactor has been developed. High magnetic field (B/sub t/ = 7.4 T) and moderate elongation (b/a = 1.6) permit operation at the high density (n(0) approximately 5 x 10 14 cm -3 ) needed for ignition in a relatively small plasma, with a spatially-averaged toroidal beta of only 4%. A unique design for the Nb 3 Sn toroidal-field magnet system reduces the stress in the high-field trunk region, and allows modularization for simpler disassembly. The modest value of toroidal beta permits a simple, modularized plasma-shaping coil system, located inside the TF coil trunk. Heating of the dense central plasma is attained by the use of ripple-assisted injection of 120-keV D 0 beams. The ripple-coil system also affords dynamic control of the plasma temperature during the burn period. A FLIBE-lithium blanket is designed especially for high-power-density operation in a high-field environment, and gives an overall tritium breeding ratio of 1.05 in the slowly pumped lithium

  17. High density harp for SSCL linac

    International Nuclear Information System (INIS)

    Fritsche, C.T.; Krogh, M.L.; Crist, C.E.

    1993-01-01

    AlliedSignal Inc., Kansas City Division, and the Superconducting Super Collider Laboratory (SSCL) are collaboratively developing a high density harp for the SSCL linac. This harp is designed using hybrid microcircuit (HMC) technology to obtain a higher wire density than previously available. The developed harp contains one hundred twenty-eight 33-micron-diameter carbon wires on 0.38-mm centers. The harp features an onboard broken wire detection circuit. Carbon wire preparation and attachment processes were developed. High density surface mount connectors were located. The status of high density harp development will be presented along with planned future activities

  18. High density harp for SSCL linac

    International Nuclear Information System (INIS)

    Fritsche, C.T.; Krogh, M.L.

    1993-05-01

    AlliedSignal Inc., Kansas City Division, and the Superconducting Super Collider Laboratory (SSCL) are collaboratively developing a high density harp for the SSCL linac. This harp is designed using hybrid microcircuit (HMC) technology to obtain a higher wire density than previously available. The developed harp contains one hundred twenty-eight 33-micron-diameter carbon wires on 0.38-mm centers. The harp features an onboard broken wire detection circuit. Carbon wire preparation and attachment processes were developed. High density surface mount connectors were located. The status of high density harp development will be presented along with planned future activities

  19. Dynamic response of HTS composite tapes to pulsed currents

    International Nuclear Information System (INIS)

    Meerovich, V; Sokolovsky, V; Prigozhin, L; Rozman, D

    2006-01-01

    Dynamic voltage-current characteristics of an HTS Ag/BiSCCO composite tape are studied both experimentally and theoretically. The tape is subjected to pulsed currents with different shapes and magnitudes and voltage traces are measured using the four-point method with different locations of potential taps on the sample surface. Clockwise and anticlockwise hysteresis loops are obtained for the same sample depending on the location of the potential taps. The dynamic characteristics deviate substantially from the DC characteristic, especially in the range of low voltages where a criterion for the critical current value is usually chosen (1-10 μV cm -1 ). The critical current determined from dynamic characteristics and its change with the pulse magnitude depend on the location of the potential taps and on the curve branch chosen for the critical current determination (ascending or descending). The theoretical analysis is based on a model of the magnetic flux diffusion into a composite tape for a superconductor described by the flux creep characteristic. Numerical simulation based on this model gives results in good agreement with the experimental ones and explains the observed peculiarities of the dynamic characteristics of HTS composite tapes. The difference between the magnetic diffusion into a tape and a slab is discussed

  20. High density dispersion fuel

    International Nuclear Information System (INIS)

    Hofman, G.L.

    1996-01-01

    A fuel development campaign that results in an aluminum plate-type fuel of unlimited LEU burnup capability with an uranium loading of 9 grams per cm 3 of meat should be considered an unqualified success. The current worldwide approved and accepted highest loading is 4.8 g cm -3 with U 3 Si 2 as fuel. High-density uranium compounds offer no real density advantage over U 3 Si 2 and have less desirable fabrication and performance characteristics as well. Of the higher-density compounds, U 3 Si has approximately a 30% higher uranium density but the density of the U 6 X compounds would yield the factor 1.5 needed to achieve 9 g cm -3 uranium loading. Unfortunately, irradiation tests proved these peritectic compounds have poor swelling behavior. It is for this reason that the authors are turning to uranium alloys. The reason pure uranium was not seriously considered as a dispersion fuel is mainly due to its high rate of growth and swelling at low temperatures. This problem was solved at least for relatively low burnup application in non-dispersion fuel elements with small additions of Si, Fe, and Al. This so called adjusted uranium has nearly the same density as pure α-uranium and it seems prudent to reconsider this alloy as a dispersant. Further modifications of uranium metal to achieve higher burnup swelling stability involve stabilization of the cubic γ phase at low temperatures where normally α phase exists. Several low neutron capture cross section elements such as Zr, Nb, Ti and Mo accomplish this in various degrees. The challenge is to produce a suitable form of fuel powder and develop a plate fabrication procedure, as well as obtain high burnup capability through irradiation testing

  1. High regression rate, high density hybrid fuels, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR program will investigate high energy density novel nanofuels combined with high density binders for use with an N2O oxidizer. Terves has developed...

  2. ANKLE TAPING DOES NOT IMPAIR PERFORMANCE IN JUMP OR BALANCE TESTS

    Directory of Open Access Journals (Sweden)

    Javier Abián-Vicén

    2008-09-01

    Full Text Available This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96. The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed

  3. Study on influence of irradiation vulcanization to silicon rubber autohesive tape's properties

    International Nuclear Information System (INIS)

    Chen Chun; Tang Jian; Wu Ling; Han Yingchun; Zhou Hong; Mo Yan; Fu Haijun

    2006-01-01

    After using 60 Co γ-ray to irradiate vulcanization silicon rubber autohesive tape, the effect of absorbed dose to the autohesive tape's tensile strength, elongation at break, autohesion and breakdown voltage strength and dose rate's effect to the autohesive tape's properties were studied. The results indicate that autohesive tape's tensile strength increases and the elongation at break decreases with the increasing dose. Under the dose of 25 kGy, the tape's autohesion increases with the increasing dose. When the dose is up to 25 kGy, the tape's autohesion achieves to the maximum, and then decreases with the increasing dose. Absorbed dose has no effect to the tape's breakdown voltage strength, and the dose rate has no effect to the autohesive tape's properties. (authors)

  4. Kinesio Taping to generate skin convolutions is not better than sham taping for people with chronic non-specific low back pain: a randomised trial

    Directory of Open Access Journals (Sweden)

    Patrícia do Carmo Silva Parreira

    2014-06-01

    Full Text Available Question: For people with chronic low back pain, does Kinesio Taping, applied according to the treatment manual to create skin convolutions, reduce pain and disability more than a simple application without convolutions? Design: Randomised trial with concealed allocation, intention-to-treat analysis and blinded assessment of some outcomes. Participants: 148 participants with chronic non-specific low back pain. Intervention: Experimental group participants received eight sessions (over four weeks of Kinesio Taping applied according to the Kinesio Taping Method treatment manual (ie, 10 to 15% tension applied in flexion to create skin convolutions in neutral. Control group participants received eight sessions (over four weeks of Kinesio Taping with no tension, creating no convolutions. Outcome measures: The primary outcome measures were pain intensity and disability after the four-week intervention. Secondary outcomes were pain intensity and disability 12 weeks after randomisation, and global perceived effect at both four and 12 weeks after randomisation. Results: Applying Kinesio Tape to create convolutions in the skin did not significantly change its effect on pain (MD–0.4 points, 95% CI–1.3 to 0.4 or disability (MD–0.3 points, 95% CI–1.9 to 1.3 at four weeks. There was a small difference in favour of the experimental group for the secondary outcome of global perceived effect (MD 1.4 points, 95% CI 0.3 to 2.5 at four weeks. No significant between-group differences were observed for the other secondary outcomes. Conclusion: Kinesio Taping applied with stretch to generate convolutions in the skin was no more effective than simple application of the tape without tension for the outcomes measured. These results challenge the proposed mechanism of action of this therapy. Trial registration: Brazilian Registry of Clinical Trials, RBR-7ggfkv. [Parreira PCS, Costa LCM, Takahashi R, Hespanhol Junior LC, da Luz Junior MA, da Silva TM, Costa LOP

  5. CLEARANCE OF ARCHIVE TAPE VAULT (BUILDING 186)

    CERN Multimedia

    EP Division

    1999-01-01

    The archive tape vault is being cleared to make way for the LHC experiments silicon facility.Experiments were contacted in February to arrange for the extended storage or destruction of archived volumes. Any who have not yet done so are asked to contactR. Minchin/IT immediately.This is also an opportunity to clear unused tapes or cartridges from around the site and have them destroyed ecologically. Please contact ep.smi.helpdesk@cern.ch to arrange for collection.A.E. Ball/EP-SMI

  6. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    Energy Technology Data Exchange (ETDEWEB)

    Grin, A. [Building Science Corporation, Somerville, MA (United States); Lstiburek, J. [Building Science Corporation, Somerville, MA (United States)

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  7. Mirror-Touch and Ticker Tape Perceptions in Synesthesia

    Directory of Open Access Journals (Sweden)

    Charlotte Anne Chun

    2013-11-01

    Full Text Available A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia’s connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person’s arm being stroked can evoke physical touch sensation on one’s own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker’s mouth. To explore synesthesia’s associations with these phenomena, a diverse group (n=3,743 was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1,017 eligible respondents, synesthetes (across all subtypes reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However effect size was small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2 to 4% and sequence-space synesthesia (9 to 14%. Within synesthesia, grapheme-personification, also called ordinal-linguistic personification was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect

  8. High aspect ratio problem in simulation of a fault current limiter based on superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Velichko, A V; Coombs, T A [Electrical Engineering Division, University of Cambridge (United Kingdom)

    2006-06-15

    We are offering a solution for the high-aspect-ratio problem relevant to the numerical simulation of AC loss in superconductors and metals with high aspect (width-to-thickness) ratio. This is particularly relevant to simulation of fault current limiters (FCLs) based on second generation YBCO tapes on RABiTS. By assuming a linear scaling of the electric and thermal properties with the size of the structure, we can replace the real sample with an effective sample of a reduced aspect ratio by introducing size multipliers into the equations that govern the physics of the system. The simulation is performed using both a proprietary equivalent circuit software and a commercial FEM software. The correctness of the procedure is verified by simulating temperature and current distributions for samples with all three dimensions varying within 10{sup -3}-10{sup 3} of the original size. Qualitatively the distributions for the original and scaled samples are indistinguishable, whereas quantitative differences in the worst case do not exceed 10%.

  9. High aspect ratio problem in simulation of a fault current limiter based on superconducting tapes

    International Nuclear Information System (INIS)

    Velichko, A V; Coombs, T A

    2006-01-01

    We are offering a solution for the high-aspect-ratio problem relevant to the numerical simulation of AC loss in superconductors and metals with high aspect (width-to-thickness) ratio. This is particularly relevant to simulation of fault current limiters (FCLs) based on second generation YBCO tapes on RABiTS. By assuming a linear scaling of the electric and thermal properties with the size of the structure, we can replace the real sample with an effective sample of a reduced aspect ratio by introducing size multipliers into the equations that govern the physics of the system. The simulation is performed using both a proprietary equivalent circuit software and a commercial FEM software. The correctness of the procedure is verified by simulating temperature and current distributions for samples with all three dimensions varying within 10 -3 -10 3 of the original size. Qualitatively the distributions for the original and scaled samples are indistinguishable, whereas quantitative differences in the worst case do not exceed 10%

  10. String and Sticky Tape Experiments.

    Science.gov (United States)

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  11. Mechanical properties of Bi,Pb(2223) single filaments and Ic(ε) behaviour in longitudinally strained tapes

    International Nuclear Information System (INIS)

    Passerini, Reynald; Dhalle, Marc; Seeber, Bernd; Fluekiger, Rene

    2002-01-01

    The Young's modulus and fracture stress of isolated Bi,Pb(2223) filaments were deduced from three-point bending tests performed at different stages of the tapes preparation. These results were introduced in the model describing the evolution of critical current of tapes submitted to a longitudinal strain in view to predict their irreversible strain limit ε irr . These calculated irreversible strain limits were compared to measured values, taken from a set of tapes made with different filling factors and composite matrices. This experiment shows that the predicted irreversible strain limits correspond to the measured ones. Presenting the I c behaviour of highly stressed tapes in a magnetic field, we discuss the evolution of the ratio I strong c0 /I c0 versus strain. This value, representative of the fraction of the critical current attributed to strongly connected grains, increases significantly during the crack formation regime at ε > ε irr . This indicates that mechanically weak links correspond to electromagnetically weak ones. This result is further confirmed by comparing the modulus of rupture obtained in single filaments extracted from tapes with different I c values

  12. On the weld strength of in situ tape placed reinforcements on weave reinforced structures

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Rietman, Bert; Akkerman, Remko

    2012-01-01

    Unidirectionally reinforced thermoplastic tapes were welded onto woven fabric reinforced laminates using a laser assisted tape placement process. A mandrel peel setup was used to quantify the interfacial fracture toughness between the tape and the laminate as a measure for weld strength. The tape

  13. Effect of dc field on ac-loss peak in a commercial Bi:2223/Ag tape

    Science.gov (United States)

    Öztürk, Ali; Düzgün, İbrahim; Çelebi, Selahattin

    2017-12-01

    Measurements of the ac susceptibility in a commercial Bi:2223/Ag tape for some different ac magnetic field amplitudes, Hac, in the presence of bias magnetic field Hdc directed along Hac are reported. It is found that the peak values of the imaginary component of ac susceptibility χ″max versus Hac trace a valley for the orientation where applied field Ha perpendicular to wide face of the tape total. We note that the observation of the valley depends on various parameters such as field dependence parameter n in the critical current density, in the simple power law expression jc = α(T)/Bn, choice of the bias field Hdc together with selected ac field amplitudes Hac, and dimension and geometry of sample studied. Our calculations based on critical state model with jc = α(1 - T/Tcm)p/Bn using the fitting parameters of n = 0.25, p = 2.2, Tcm = 108 K gives quite good results to compare the experimental and calculated curves.

  14. Inertial and stick-slip regimes of unstable adhesive tape peeling.

    Science.gov (United States)

    Dalbe, Marie-Julie; Villey, Richard; Ciccotti, Matteo; Santucci, Stéphane; Cortet, Pierre-Philippe; Vanel, Loïc

    2016-05-18

    We present an experimental characterization of the detachment front unstable dynamics observed during the peeling of pressure sensitive adhesives. We use an experimental set-up specifically designed to control the peeling angle θ and the peeled tape length L, while peeling an adhesive tape from a flat substrate at a constant driving velocity V. High-speed imaging allows us to report the evolution of the period and amplitude of the front oscillations, as well as the relative durations of their fast and slow phases, as a function of the control parameters V, L and θ. Our study shows that, as the driving velocity or the peeling angle increases, the oscillations of the peeling front progressively evolve from genuine "stick-slip" oscillations, made of alternating long stick phases and very brief slip phases, to sinusoidal oscillations of amplitude twice the peeling velocity. We propose a model which, taking into account the peeling angle-dependent kinetic energy cost to accelerate and decelerate the peeled tape, explains the transition from the "stick-slip" to the "inertial" regime of the dynamical instability. Using independent direct measurements of the effective fracture energy of the adhesive-substrate joint, we show that our model quantitatively accounts for the two regimes of the unstable dynamics.

  15. VHS-tape system for general purpose computer. For next generation mass storage system

    International Nuclear Information System (INIS)

    Ukai, K.; Takano, M.; Shinohara, M.; Niki, K.; Suzuki, Y.; Hamada, T.; Ogawa, M.

    1994-07-01

    Mass storage is one of the key technology of next generation computer system. A huge amount of data is produced on a field of particle and nuclear physics. These data are raw data of experiments, analysis data, Monte Carlo simulations data, etc. We search a storage device for these data at the point of view of capacity, price, size, transfer speed, etc. We have selected a VHS-tape (12.7 mm-tape, helical scan) from many storage devices. Characteristics of the VHS-tape are as follows; capacity of 14.5 GB, size of 460 cm 3 , price of 1,000 yen (S-VHS tape for video use), and 1.996 MB/sec transfer speed at a sustained mode. Last year, we succeeded to operate the VHS-tape system on a workstation as a I/O device with read/write speed of 1.5 MB/sec. We have tested a VHS-tape system by connecting to the channel of the general purpose computer (Fujitsu M-780/10S) in our institute. We obtained a read and write speeds of 1.07 MB/sec and 1.72 MB/sec by FORTRAN test programs, respectively. Read speeds of an open reel tape and a 3480 type cassete tape by the same test programs are 1.13 MB/sec and 2.54 MB/sec, respectively. Speeds of write operation are 1.09 MB/sec and 2.54 MB/sec for the open reel and 3480 cassete tape, respectively. A start motion of the VHS-tape for read/write operations needs about 60 seconds. (author)

  16. The Catalog: A Flexible Data Structure for Magnetic Tape.

    Science.gov (United States)

    Kay, Martin; Ziehe, Theodore

    This report outlines a generalized storage scheme for large files of highly structured data, or catalogs, and describes their realization on magnetic tape. Each datum, large or small, is assigned to one of a number of data classes of which a user may define any number. The over-all organization of a catalog is given by a map that imposes a tree…

  17. Torsional Properties of TiNi Shape Memory Alloy Tape for Rotary Actuator

    Science.gov (United States)

    Takeda, K.; Tobushi, H.; Mitsui, K.; Nishimura, Y.; Miyamoto, K.

    2012-12-01

    In order to develop novel shape memory actuators, the torsional deformation of a shape memory alloy (SMA) tape and the actuator models driven by the tape were investigated. The results obtained can be summarized as follows. In the SMA tape subjected to torsion, the martensitic transformation appears along both edges of the tape due to elongation of these elements and grows to the central part. The fatigue life in both the pulsating torsion and alternating torsion is expressed by the unified relationship of the dissipated work in each cycle. Based on an opening and closing door model and a solar-powered active blind model, the two-way rotary driving actuator with a small and simple mechanism can be developed by using torsion of the SMA tape.

  18. Does Kinesiology tape counter exercise-related impairments of balance in the elderly?

    Science.gov (United States)

    Hosp, Simona; Csapo, Robert; Heinrich, Dieter; Hasler, Michael; Nachbauer, Werner

    2018-05-01

    Maintaining balance is an essential requirement for the performance of daily tasks and sporting activities, particularly in older adults to prevent falls and associated injuries. Kinesiology tape has gained great popularity in sports and is frequently used as a tool for performance enhancement. However, there is little research investigating its influence on balance. The purpose of this study was to evaluate the effect of Kinesiology tape on dynamic balance, postural stability and knee proprioception after physical activity in healthy, older adults. Twelve physically active, healthy men aged 63-77 years performed the test on two separate days, with and without Kinesiology tape at the knee joint (prospective intervention with cross-over design). Dynamic balance during an obstacle-crossing task, postural stability in a single-leg stance test, and knee joint position sense as a measure of proprioception were examined before and after 30 min of downhill walking on a treadmill. The influences of taping condition and physical activity on all parameters were statistically tested using factorial ANOVAs. Factorial ANOVA revealed significant time × taping condition interaction effects on all performance parameters (p postural stability and knee proprioception differed between the two taping conditions. The deterioration of performance was always greater when no tape was used. This study demonstrated that physical exercise significantly deteriorated dynamic balance, postural stability and knee proprioception in older men. These effects can be attenuated through the usage of Kinesiology tape. By preventing exercise-related impairments of balance, Kinesiology tape might help reduce the risk of sports-associated falls and associated injuries. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

    Science.gov (United States)

    Costen, Robert C.

    2000-01-01

    Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

  20. Effect of Mulligan's and Kinesio knee taping on adolescent ballet dancers knee and hip biomechanics during landing.

    Science.gov (United States)

    Hendry, D; Campbell, A; Ng, L; Grisbrook, T L; Hopper, D M

    2015-12-01

    Taping is often used to manage the high rate of knee injuries in ballet dancers; however, little is known about the effect of taping on lower-limb biomechanics during ballet landings in the turnout position. This study investigated the effects of Kinesiotape (KT), Mulligan's tape (MT) and no tape (NT) on knee and hip kinetics during landing in three turnout positions. The effect of taping on the esthetic execution of ballet jumps was also assessed. Eighteen pain-free 12-15-year-old female ballet dancers performed ballet jumps in three turnout positions, under the three knee taping conditions. A Vicon Motion Analysis system (Vicon Oxford, Oxford, UK) and Advanced Mechanical Technology, Inc. (Watertown, Massa chusetts, USA) force plate collected lower-limb mechanics. The results demonstrated that MT significantly reduced peak posterior knee shear forces (P = 0.025) and peak posterior (P = 0.005), medial (P = 0.022) and lateral (P = 0.014) hip shear forces compared with NT when landing in first position. KT had no effect on knee or hip forces. No significant differences existed between taping conditions in all landing positions for the esthetic measures. MT was able to reduce knee and the hip forces without affecting the esthetic performance of ballet jumps, which may have implications for preventing and managing knee injuries in ballet dancers. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. A software package to process an INIS magnetic tape on the VAX computer

    International Nuclear Information System (INIS)

    Omar, A.A.; Mohamed, F.A.

    1991-01-01

    This paper presents a software package whose function is to process the magnetic tapes distributed by the Atomic Energy Agency, on the VAX computers. These tapes contain abstracts of papers in the different branches of nuclear field and is supplied from the international Nuclear Information system (INIS). Two goals are aimed from this paper. First it gives a procedure to process any foreign magnetic tape on the VAX computers. Second, it solves the problem of reading the INIS tapes on a non IBM computer and thus allowing the specialists to gain from the large amount of information contained in these tapes. 11 fig

  2. Tape cast isotropic, fine-grained tungsten for thermo-cyclic loading applications

    Energy Technology Data Exchange (ETDEWEB)

    Sommerer, Mathias, E-mail: Mathias.Sommerer@tum.de [Lehrstuhl für Werkstoffkunde und Werkstoffmechanik, Technische Universität München, Boltzmannstr. 15, 85748 Garching (Germany); Li, Muyuan [Max-Planck-Institut für Plasma Physik, Boltzmannstraße 2, 85748 Garching (Germany); Werner, Ewald [Lehrstuhl für Werkstoffkunde und Werkstoffmechanik, Technische Universität München, Boltzmannstr. 15, 85748 Garching (Germany); Dewitz, Hubertus von; Walter, Steffen; Lampenscherf, Stefan [Siemens AG, Corporate Technology, Otto-Hahn-Ring 6, 81730 München (Germany); Arnold, Thomas [Siemens Healthcare GmbH, Henkestr. 127, 91052 Erlangen (Germany)

    2016-04-15

    Highlights: • The tape casting process for tungsten is described. • A set-up of a HHF test facility for standing anodes is presented. • The thermo-cyclic behavior of tape cast tungsten and a reference is investigated. • The evolution of crack patterns is described in dependency of HHF-loadings. • The surface roughness of X-ray anodes is related to the microstructural evolution. - Abstract: This paper introduces tape casting as a new route for the production of isotropic and fine-grained tungsten components. Microstructural and thermal properties of tape cast tungsten samples are determined. Thermal shock behavior according to the thermo-cyclic loading of standing X-ray anodes is investigated and compared to the behavior of a rolled tungsten grade. The development of surface roughness during the thermal shock loading is discussed in relation to the development of the grain structure and crack pattern. The fine-grained and stable microstructure of the tape cast material exhibits less roughening under such test conditions.

  3. Magnetization of High Density Hadronic Fluid

    DEFF Research Database (Denmark)

    Bohr, Henrik; Providencia, Constanca; da Providencia, João

    2012-01-01

    In the present paper the magnetization of a high density relativistic fluid of elementary particles is studied. At very high densities, such as may be found in the interior of a neutron star, when the external magnetic field is gradually increased, the energy of the normal phase of the fluid...... in the particle fluid. For nuclear densities above 2 to 3 rho(0), where rho(0) is the equilibrium nuclear density, the resulting magnetic field turns out to be rather huge, of the order of 10(17) Gauss....

  4. Superconducting joint of Bi-2223/Ag superconducting tapes by diffusion bonding

    International Nuclear Information System (INIS)

    Guo Wei; Zou Guisheng; Wu Aiping; Wang Yanjun; Bai Hailin; Ren Jialie

    2009-01-01

    61-Filaments Bi-2223/Ag superconducting tapes have been joined by diffusion bonding. The critical currents (I C s) of the joints are obtained by using standard four probe method under no magnetic field in the liquid nitrogen. The microstructures of the joints are evaluated by the electron microscope in electron backscatter diffraction mode and the phase compositions of the superconducting cores of the joint and the original tape are determined by X-ray diffraction (XRD). The results show diffusion bonding is effective bonding technique for HTS tapes, and the bonding time is reduced greatly from hundreds of hours to a few hours, and the bonding pressure also changes from 140-4000 MPa to 3 MPa. Furthermore, the diffusion bonding joints sustain superconducting properties, and the critical current ratios (CCR O ) of the joints are in the range of 35%-80%. Microstructures of the typical joint display a good bonding and some defects existed in traditional method are avoided. XRD results show that the phase compositions of the superconducting cores have no obvious changes before and after diffusion bonding, which offers physical and material bases for high superconducting property of the joints.

  5. Modelling of Tape Casting for Ceramic Applications

    DEFF Research Database (Denmark)

    Jabbari, Masoud

    was increased by improving the steady state model with a quasi-steady state analytical model. In order to control the most important process parameter, tape thickness, the two-doctor blade configuration was also modeled analytically. The model was developed to control the tape thickness based on the machine...... for magnetic refrigeration applications. Numerical models were developed to track the migration of the particles inside the ceramic slurry. The results showed the presence of some areas inside the ceramic in which the concentration of the particles is higher compared to other parts, creating the resulting...

  6. Transaction aware tape-infrastructure monitoring

    International Nuclear Information System (INIS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-01-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  7. Preparation of YBaCuO superconducting tape by RF magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Fukutomi, Masao; Akutsu, Nakao; Tanaka, Yoshiaki; Asano, Toshihisa; Maeda, Hiroshi (National Research Inst. for Metals, Tsukuba (Japan); Mitsui Mining and Smelting Co., Ltd., Tokyo (Japan))

    1989-04-01

    The effect of buffer layers, conditions of film preparation, and the relation between superconducting characteristics and bombardment of high energy ions on films were discussed in an attempt to fabricate YBaCuO films on metallic substrates by sputtering. Hastelloy-X tapes and Chromel (Ni-10Cr) fine wires were used as metallic substrates, and MgO films as buffer layers, which were provided by sputtering a MgO sintered target and annealing. As a result, superconducting films were favorably obtained on the Hastelloy tapes with the MgO buffer layers, however, counter diffusion at the interface of the film and layer was unavoidable in annealing. C axis-highly oriented film with high zero resistance Tc was obtained in such an arrangement of the target and substrate as to lower the effect of 0{sup {minus}} ion resputtering, resulting in the most favorable Tc=80.4K. YBaCuO superconducting films could be also deposited on a bundle of Chromel fine wires preliminarily. 11 refs., 7 figs.

  8. Electrical and mechanical properties of Bi-2223/Ag/barrier/Ag composite tapes

    International Nuclear Information System (INIS)

    Kovac, P.; Husek, I.; Goemoery, F.; Oduleye, O.O.; Alford, N.McN.; Pachla, W.; Diduszko, R.

    2000-01-01

    Bi-2223/Ag/barrier/Ag single-core tapes with various oxide barrier materials (BaZrO 3 , SrCO 3 , ZrO 2 and Al 2 O 3 ) have been prepared by PIT. The I-V curves and ac susceptibility measurements have been performed for tapes with identical heat treatment history. Young's moduli of these tape samples have been evaluated by three-point bending and the structure of barrier powders and BSCCO cores was analysed by SEM and XRD, respectively. It was found that the shape of I-V curves, the current transfer lengths and the mechanical properties of tapes are all affected by the oxide barrier type and the barrier thickness, as well as by its porosity and uniformity. This is because the oxide barrier controls the oxygen diffusion during the tape heat treatment and simultaneously the HTS phase formation kinetics, its purity and content within the superconducting core. On the base of the results obtained for single-core tapes, two kinds of multifilamentary composite were made and tested. (author)

  9. Tape measure to aid prescription in paediatric resuscitation.

    OpenAIRE

    Hughes, G; Spoudeas, H; Kovar, I Z; Millington, H T

    1990-01-01

    A tape measure, based on 50th centile weight for height and designed to permit easy drug dosage calculation, endotracheal tube size and DC cardioversion current dosages in childrens' emergencies, was tested for reliability by medical and nursing staff with varying paediatric experience. We found that the tape measure gave a reproducible estimate of weight and suggest that its use would facilitate decision making by inexperienced medical and nursing staff in paediatric resuscitation when there...

  10. Multilayer tape cast SOFC – Effect of anode sintering temperature

    DEFF Research Database (Denmark)

    Hauch, Anne; Birkl, Christoph; Brodersen, Karen

    2012-01-01

    Multilayer tape casting (MTC) is considered a promising, cost-efficient, up-scalable shaping process for production of planar anode supported solid oxide fuel cells (SOFC). Multilayer tape casting of the three layers comprising the half cell (anode support/active anode/electrolyte) can potentially...

  11. Development and manufacturing of tape casted, anode-supported solid oxide fuel cells; Entwicklung und Herstellung von foliengegossenen, anodengestuetzten Festoxidbrennstoffzellen

    Energy Technology Data Exchange (ETDEWEB)

    Schafbauer, Wolfgang

    2010-07-01

    Solid oxide fuel cells offer high potential in transforming the chemical energy of hydrogen or natural gas into electrical energy. Due to the high efficiency of fuel cells, lots of effort has been made in the improvement of net efficiency and in materials development during the last years. Recently, the introduction of high performance, low-cost production technologies become more and more important. At the Institute of Energy Research IEF-1 of Forschungszentrum Julich, standard SOFCs were processed by time and work consuming methods. On the way to market entrance, product costs have to be reduced drastically. The aim of this thesis is the introduction of a high efficient low-cost processing route for the SOFC manufacturing. Therefore, the well-known and well established shaping technology tape casting was used for generating the anode substrates. As the first goal of this approach, two different tape casting slurries were developed in order to get substrates in the thickness range from 300 to 500 {mu}m after sintering. After shaping of the substrates, sinter regimes for the different necessary coatings were adapted to the novel substrate types in order to obtain cells with high performance and strength. Therefore, the different coating technologies like screen printing and vacuum slip casting were used for cell manufacturing. The optimization of the different coating steps during cell manufacturing led to high performance SOFCs with a 10% higher power output compared to the Julich state-of-the-art SOFC. Additional experiments verified the workability of the novel tape cast substrates for the manufacturing of near-net-shape SOFC. Finally, the novel cell types based on tape cast substrates were assembled to stacks with up to ten repeating units. Stack tests showed identical performance and degradation compared to stacks containing state-of-the-art SOFCs. Thus, the complete lifetime circle of a SOFC starting from powder preparation to stack assembly has been

  12. ICI optical data storage tape: An archival mass storage media

    Science.gov (United States)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  13. Forensic Pollen Evidence from Clothes by the Tape Adhesive Method

    Directory of Open Access Journals (Sweden)

    Chun-Liang Wu

    2006-06-01

    Full Text Available Collection and identification of pollen is becoming important in forensic applications. Many criminal cases have been reported to link suspects to the crime scene by analysis of pollen. Several methods have been used in the pollen collection and analysis, but they are expensive and tedious. Therefore, it is important to develop a simple method to collect pollen grains from clothes. We tried to recover pollen from clothing surface by using the sticky tapes method. The tape adhesive method has been widely used for sample collection for various purposes, but the efficiency of recovery of invisible pollen from clothes has rarely been reported. Therefore, to test the efficiency of the tape adhesive method in recovering pollen from clothes is important. The first author wore clothes that were made from textile S made by the mixture of cotton 60% and polyester fiber 40% to collect pollen from 26 different areas mostly in the northern part of Taiwan and then used cellophane tape D (Sirchie Finger Print Lab., Inc-No. 131LT4 to recover them from different body parts. Twenty-six pollen taxa were detected in different parts of clothes depending upon what kind of plant the first author stayed near. From the results, we concluded that the tape adhesive method is suitable in recovering pollen from clothes. We have suggested that the tape adhesive method could be part of methods for collecting pollen from clothes of suspects. It is simpler, faster and less expensive than other methods.

  14. The augmentation of heat transfer in a pipe flow using a swirling perforated twisted (SPT) tape insert

    Science.gov (United States)

    Ahmad, Shahrokh; Oishe, Sadia Noon; Rahman, Md. Lutfor

    2017-12-01

    The purpose of this research work is to increase the heat transfer coefficient by operating the heat exchangers at smaller revolution per minute. This signifies an achievement of reduction of pressure drop corresponding to less operating cost. This study has used two types of SPT tape insert to observe the various heat transfer coefficient, heat transfer rate and heat transfer augmentation efficiency. One tape was fully twisted and another tape was partially twisted. The shape of the SPT tape creates turbulence effect. The turbulence flow (swirl flow) generated by SPT tape promotes greater mixing and high heat transfer coefficients. An arrangement scheme has been developed for the experimental investigation. For remarking the rate of change of heat transfer, temperature has been measured numerically through the temperature sensors with various flow rates and RPM. The volume flow rate was varied from 10.3448276 LPM to 21.045574 LPM and the rotation of the perforated twisted tape was varied from 50 RPM to 400 RPM. Finally the research study demonstrates the effectiveness of the results of the proposed approaches. It is observed that the suggested method of heat transfer augmentations is much more effective than existing methods, since it results in an increase in heat transfer area and also an increase in the heat transfer coefficient and reduction of cost in the industrial sectors.

  15. Numerical investigation of heat transfer and friction factor characteristics in a circular tube fitted with V-cut twisted tape inserts.

    Science.gov (United States)

    Salman, Sami D; Kadhum, Abdul Amir H; Takriff, Mohd S; Mohamad, Abu Bakar

    2013-01-01

    Numerical investigation of the heat transfer and friction factor characteristics of a circular fitted with V-cut twisted tape (VCT) insert with twist ratio (y = 2.93) and different cut depths (w = 0.5, 1, and 1.5 cm) were studied for laminar flow using CFD package (FLUENT-6.3.26). The data obtained from plain tube were verified with the literature correlation to ensure the validation of simulation results. Classical twisted tape (CTT) with different twist ratios (y = 2.93, 3.91, 4.89) were also studied for comparison. The results show that the enhancement of heat transfer rate induced by the classical and V-cut twisted tape inserts increases with the Reynolds number and decreases with twist ratio. The results also revealed that the V-cut twisted tape with twist ratio y = 2.93 and cut depth w = 0.5 cm offered higher heat transfer rate with significant increases in friction factor than other tapes. In addition the results of V-cut twist tape compared with experimental and simulated data of right-left helical tape inserts (RLT), it is found that the V-cut twist tape offered better thermal contact between the surface and the fluid which ultimately leads to a high heat transfer coefficient. Consequently, 107% of maximum heat transfer was obtained by using this configuration.

  16. Evaluation of the Effect of Different Irrigation Levels of Drip Irrigation (Tape on Yield and Yield Components of Corn

    Directory of Open Access Journals (Sweden)

    mohammad karimi

    2016-02-01

    Full Text Available Introduction: One of the serious problems in the further development of maize cultivation is increasing irrigation efficiency. Using conventional irrigation causes a shortage of water resources to increase the acreage of the crop. With regard to the development of maize cultivation, agronomic and executable methods must be studied to reduce water consumption. Using drip irrigation system is most suitable for row crops. Hamedi et al. (2005 compared drip (tape and surface irrigation systems on yield of maize in different levels of water requirement and indicated that drip irrigation increases the amount of yield to 2015 kg/ha and water use efficiency to 3 time. Kohi et al. (2005 investigated the effects of deficit irrigation use of drip (tape irrigation on water use efficiency on maize in planting of one and two rows. The results showed that maximum water use efficiency related to crop density, water requirement and planting pattern 85000, 125% and two rows, respectively with 1.46 kg/m3. Jafari and Ashrafi (2011 studied the effects of irrigation levels, plant density and planting pattern in drip irrigation (tape on corn. The results showed that the amount of irrigation water and crop density on the level of 1% and their interactions and method of planting were significant at the 5 and 10% on water use efficiency, respectively. The yield was measured under different levels of irrigation, crop density and method of planting and the difference was significant on the level of 1%. Lamm et al. (1995 studied water requirement of maize in field with silt loam texture under sub drip irrigation and reported that water use reduced to 75%; but yield of maize remained at maximum amount of 12.5 t/ha. The objective of this study was to evaluate the drip (tape irrigation method for corn production practices in the Qazvin province in Iran. Materials and Methods: In this study, yield and yield components of corn (SC 704 were investigated under different levels of

  17. Ultrasound assessment of tension-free vaginal tape (TVT).

    Science.gov (United States)

    Flock, F; Kohorst, F; Kreienberg, R; Reich, A

    2011-01-01

    To date, no standardization for the visualization of tension-free vaginal tape (TVT) has been established in clinical practice. The aim of this prospective observational study was to evaluate the shape and position of the tape using ultrasound and to compare this data with clinical postoperative results. In a three-year period, 296 patients with clinically and urodynamically proven stress urinary incontinence (SUI) were treated with TVT and received follow-up in our department. An additional 12 patients, who were initially treated in other hospitals and had postoperative problems, were included in this study. Depending on the outcome after 3 months, the patients were divided into groups with and without specific disorders. The TVT was evaluated by introital ultrasound. The position of the tape was established by its location in relation to the urethral length and the distance to the hypoechoic center of the urethra (HCU). A suitable TVT position was determined in patients without any postoperative disorders. The mean value for the TVT position at rest in relation to the urethral length was 61 %. The distance to the HCU was 4.6 ± 1.5 mm. In patients with persistent SUI, the tape was more often located under the inner (3 % vs. 0 %) or outer quarter (29 % vs. 13 %, p = 0.004). In patients with residual volume, the distance to the urethra was significantly lower (2.7 vs. 4.6, p TVT may be regularly investigated using ultrasound. In combination with the clinical outcome, it represents an important method of evaluating the tape and assists in the planning of a future therapeutic course of action in cases of postoperative problems. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Fabrication of 100 A class, 1 m long coated conductor tapes by metal organic chemical vapor deposition and pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V.; Lee, H.G.; Li, Y.; Xiong, X.; Qiao, Y.; Reeves, J.; Xie, Y.; Knoll, A.; Lenseth, K

    2003-10-15

    SuperPower has been scaling up YBa{sub 2}Cu{sub 3}O{sub x}-based second-generation superconducting tapes by techniques such as pulsed laser deposition (PLD) using industrial laser and metal organic chemical vapor deposition (MOCVD). Both techniques offer advantage of high deposition rates, which is important for high throughput. Using highly-polished substrates produced in a reel-to-reel polishing facility and buffer layers deposited in a pilot ion beam assisted deposition facility, meter-long second-generation high temperature superconductor tapes have been produced. 100 A class, meter-long coated conductor tapes have been reproducibly demonstrated in this work by both MOCVD and PLD. The best results to date are 148 A over 1.06 m by MOCVD and 135 A over 1.1 m by PLD using industrial laser.

  19. Comparison of self-field effects between Bi-2223/Ag tapes and pancake coils

    International Nuclear Information System (INIS)

    Alamgir, A.K.M.; Gu, C.; Han, Z.

    2005-01-01

    Knowledge on self-field behavior in HTS tape and coil becomes important for the design of HTS devices. We report on the comparative nature and influence of self-field in Bi-2223/Ag tape and pancake coils in terms of critical current and ac loss. Measured dc and ac properties of short tape and pancake coils are verified based on the self-field. It is proved that perpendicular component of self-field acting in opposite direction at the two halves of tape-width determines critical current in short tape and single-turn coil. On the other hand, perpendicular component of self-field pointed in the same direction at the two halves of tape-width determines critical current in multi-turn coils. Influence of magnitude and orientation of self-field on ac loss is also investigated for a series of pancake coils based on the measured self-field ac loss in short sample

  20. Comparison of self-field effects between Bi-2223/Ag tapes and pancake coils

    Energy Technology Data Exchange (ETDEWEB)

    Alamgir, A.K.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China)]. E-mail: alam643@yahoo.com; Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China)

    2005-08-15

    Knowledge on self-field behavior in HTS tape and coil becomes important for the design of HTS devices. We report on the comparative nature and influence of self-field in Bi-2223/Ag tape and pancake coils in terms of critical current and ac loss. Measured dc and ac properties of short tape and pancake coils are verified based on the self-field. It is proved that perpendicular component of self-field acting in opposite direction at the two halves of tape-width determines critical current in short tape and single-turn coil. On the other hand, perpendicular component of self-field pointed in the same direction at the two halves of tape-width determines critical current in multi-turn coils. Influence of magnitude and orientation of self-field on ac loss is also investigated for a series of pancake coils based on the measured self-field ac loss in short sample.

  1. Ankle Taping Does Not Impair Performance in Jump or Balance Tests

    OpenAIRE

    Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests a...

  2. Effects of low-dye taping on plantar pressure pre and post exercise: an exploratory study.

    LENUS (Irish Health Repository)

    Nolan, Damien

    2009-01-01

    BACKGROUND: Low-Dye taping is used for excessive pronation at the subtalar joint of the foot. Previous research has focused on the tape\\'s immediate effect on plantar pressure. Its effectiveness following exercise has not been investigated. Peak plantar pressure distribution provides an indirect representation of subtalar joint kinematics. The objectives of the study were 1) To determine the effects of Low-Dye taping on peak plantar pressure immediately post-application. 2) To determine whether any initial effects are maintained following exercise. METHODS: 12 asymptomatic subjects participated; each being screened for excessive pronation (navicular drop > 10 mm). Plantar pressure data was recorded, using the F-scan, at four intervals during the testing session: un-taped, baseline-taped, post-exercise session 1, and post-exercise session 2. Each exercise session consisted of a 10-minute walk at a normal pace. The foot was divided into 6 regions during data analysis. Repeated-measures analysis of variance (ANOVA) was used to assess regional pressure variations across the four testing conditions. RESULTS: Reduced lateral forefoot peak plantar pressure was the only significant difference immediately post tape application (p = 0.039). This effect was lost after 10 minutes of exercise (p = 0.036). Each exercise session resulted in significantly higher medial forefoot peak pressure compared to un-taped; (p = 0.015) and (p = 0.014) respectively, and baseline-taped; (p = 0.036) and (p = 0.015) respectively. Medial and lateral rearfoot values had also increased after the second session (p = 0.004), following their non-significant reduction at baseline-taped. A trend towards a medial-to-lateral shift in pressure present in the midfoot immediately following tape application was still present after 20 minutes of exercise. CONCLUSION: Low-Dye tape\\'s initial effect of reduced lateral forefoot peak plantar pressure was lost after a 10-minute walk. However, the tape continued

  3. Effect of the Kinesio tape to muscle activity and vertical jump performance in healthy inactive people

    Directory of Open Access Journals (Sweden)

    Lu Szu-Ching

    2011-08-01

    Full Text Available Abstract Background Elastic taping applied on the triceps surae has been commonly used to improve the performance of lower extremities. However, little objective evidence has been documented. The purpose of this study was to investigate the effect of elastic taping on the triceps surae during a maximal vertical jump. It was hypothesized that elastic taping to the triceps surae would increase muscle activity and cause positive effect to jump height. Methods Thirty-one healthy adults (19 males and 12 females with mean age, body weight and height for 25.3 ± 3.8 years old, 64.1 ± 6.2 kg, and 169.4 ± 7.3 cm, respectively were recruited. All participants performed vertical jump tests prior to (without taping and during elastic taping. Two elastic tapes, Kinesio tape and Mplacebo tape from two different manufacturers, were applied to the participants, respectively. Results The results showed that the vertical ground reaction force increased when Kinesio tape was applied even when the height of jump remained about constant. However, the height of the jump decreased, and there was no difference on the vertical ground reaction force in Mplacebo taping group. Although the EMG activity of medial gastrocnemius tended to increase in Kinesio taping group, we did not see differences in EMG activity for the medial gastrocnemius, tibialis anterior and soleus muscles in either group. Conclusions Based on the varied effects of Kinesio tape and Mplacebo tape, different intervention technique was suggested for specific purpose during vertical jump movement. Mplacebo tape was demanded for the benefits of stabilization, protection, and the restriction of motion at the ankle joint. On the other hand, the findings may implicate benefits for medial gastrocnemius muscle strength and push-off force when using Kinesio tape.

  4. Efek Interaksi Ragi Tape dan Ragi Roti terhadap Kadar Bioetanol Ketela Pohon (Manihot Utilissima, Pohl Varietas Mukibat

    Directory of Open Access Journals (Sweden)

    Tri Budi Kurniawan

    2014-09-01

    and ethanol concentration (primary data. Bioethanol content data obtained were analyzed using two-way ANAVA and Duncan continued test (DMRT at the level of 5% error. The results showed that no effect of the interaction of breads yeast and tape yeast on levels of cassava bioethanol p> 0.05. The concentration of bread yeast and tape yeast yielded in high concentration of ethanol. The interaction of yeast tape 0.6% and 0.3% bread yeast (T2R1 gave the lowest effective interaction produced 36% ethanol. The interaction of tape yeast 0.9% and 0.9% bread yeast (T3R3 resulted in the highest ethanol concentration with an average reached 49.8%.

  5. A feasibility study of high-strength Bi-2223 conductor for high-field solenoids

    Science.gov (United States)

    Godeke, A.; Abraimov, D. V.; Arroyo, E.; Barret, N.; Bird, M. D.; Francis, A.; Jaroszynski, J.; Kurteva, D. V.; Markiewicz, W. D.; Marks, E. L.; Marshall, W. S.; McRae, D. M.; Noyes, P. D.; Pereira, R. C. P.; Viouchkov, Y. L.; Walsh, R. P.; White, J. M.

    2017-03-01

    We performed a feasibility study on a high-strength Bi{}2-xPb x Sr2Ca2Cu3O{}10-x(Bi-2223) tape conductor for high-field solenoid applications. The investigated conductor, DI-BSCCO Type HT-XX, is a pre-production version of Type HT-NX, which has recently become available from Sumitomo Electric Industries. It is based on their DI-BSCCO Type H tape, but laminated with a high-strength Ni-alloy. We used stress-strain characterizations, single- and double-bend tests, easy- and hard-way bent coil-turns at various radii, straight and helical samples in up to 31.2 T background field, and small 20-turn coils in up to 17 T background field to systematically determine the electro-mechanical limits in magnet-relevant conditions. In longitudinal tensile tests at 77 K, we found critical stress- and strain-levels of 516 MPa and 0.57%, respectively. In three decidedly different experiments we detected an amplification of the allowable strain with a combination of pure bending and Lorentz loading to ≥slant 0.92 % (calculated elastically at the outer tape edge). This significant strain level, and the fact that it is multi-filamentary conductor and available in the reacted and insulated state, makes DI-BSCCO HT-NX highly suitable for very high-field solenoids, for which high current densities and therefore high loads are required to retain manageable magnet dimensions.

  6. Identification and quantification of glue-like off-odors in elastic therapeutic tapes.

    Science.gov (United States)

    Denk, Philipp; Buettner, Andrea

    2018-05-01

    Elastic therapeutic tapes are an important tool in the field of physical therapy and medicine. These tapes contain types of adhesive. However, sensory evaluations revealed the release of pronounced and irritating odors of the tapes. Negative odors were, amongst others, reported in elastic therapeutic tapes containing acrylic adhesives. In this study, the odor of four different tape samples was evaluated applying a descriptive analysis approach carried out by a trained sensory panel. Afterwards, the volatile compounds were recovered from the samples by solvent extraction and isolated by solvent-assisted flavor evaporation (SAFE). The obtained distillates were subsequently analyzed by gas chromatography-olfactometry (GC-O) and two-dimensional GC-O coupled with mass spectrometry (2D-GC-MS/O). To determine the most potent odorants in the distillates, odor extract dilution analyses (OEDA) were carried out. Thirty-one odorants were successfully identified using this approach, which were all described for the first time as odorants in tapes. Amongst the set of volatiles, unsaturated and saturated aldehydes were present, eliciting fatty, soapy, and citrus-like odor impressions, as well as a range of glue-like, moldy, and fruity smelling odor-active volatiles, such as 2-ethyl-1-hexanol, butyl benzoate, and 3-phenyltoluene. Based on their relative intensities, the concentrations of the glue-like smelling substances were determined: 2-ethyl-1-hexanol, present in all samples, was determined with concentrations ranging from 10 to 200 mg/kg in the investigated tapes.

  7. Device for stretching tapes or cables intended for manipulators

    International Nuclear Information System (INIS)

    Baudoin, J.-C.; Oger, Robert.

    1975-01-01

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device [fr

  8. Device for stretching tapes or cables intended for manipulators

    Energy Technology Data Exchange (ETDEWEB)

    Baudoin, J C; Oger, R

    1975-03-06

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device.

  9. Ring shaped laser for tape winding of an endless tube

    NARCIS (Netherlands)

    Leonardus, Lucky

    2012-01-01

    AFPT is a start-up company that provides laser-assisted technology for the production of a pressurized component such as tube, pressure vessel, etc made from or strengthened by fiber reinforced plastic (FRP) tape. The tape is laid precisely by a machine head (connected to a robot), melted with a

  10. Age-of-Air, Tape Recorder, and Vertical Transport Schemes

    Science.gov (United States)

    Lin, S.-J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A numerical-analytic investigation of the impacts of vertical transport schemes on the model simulated age-of-air and the so-called 'tape recorder' will be presented using an idealized 1-D column transport model as well as a more realistic 3-D dynamical model. By comparing to the 'exact' solutions of 'age-of-air' and the 'tape recorder' obtainable in the 1-D setting, useful insight is gained on the impacts of numerical diffusion and dispersion of numerical schemes used in global models. Advantages and disadvantages of Eulerian, semi-Lagrangian, and Lagrangian transport schemes will be discussed. Vertical resolution requirement for numerical schemes as well as observing systems for capturing the fine details of the 'tape recorder' or any upward propagating wave-like structures can potentially be derived from the 1-D analytic model.

  11. Correlation between in-field critical currents in Zr-added (Gd, Y)Ba2Cu3Ox superconducting tapes at 30 and 77 K

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V; Xu, A; Liu, Y; Khatri, ND; Lei, C; Chen, Y; Galstyan, E; Majkic, G

    2014-03-11

    Critical current (I-c) values of 1384 Lambda/12 mm, corresponding to a critical current density of 12.47 MA cm(-2) and a pinning force of 374 GN m(-3), have been achieved at 30 K, 3 T in the orientation of field parallel to the c axis (B parallel to c) in (Gd, Y)BaCuO tapes with 15 mol% Zr addition made by metal organic chemical vapor deposition (MOCVD). These tapes show pinning force levels as high as 453 GN m(-3) at 30 K. An analysis of the properties of 24-28 (Gd, Y)BaCuO tapes with 15 mol% Zr addition showed a lack of correlation between their critical currents at 30 K, 3 T (B parallel to c) and I-c values both at 77 K, zero field and at 77 K, 1 T (B parallel to c). However, a strong correlation was found between the critical currents at 30 K, 3 T and at 77 K, 3 T (B parallel to c). It has also been discovered that the minimum critical current (I-c, (min)) value at 77 K, 3 T has no influence on the I-c,I- (min) value at 30 K, 3 T, and it in turn depends on the ratio of the I-c values in the orientations of field parallel and perpendicular to the c axis at 77 K, 3 T.

  12. Tape functionality: position, change in shape, and outcome after TVT procedure--mid-term results.

    Science.gov (United States)

    Kociszewski, Jacek; Rautenberg, Oliver; Kolben, Sebastian; Eberhard, Jakob; Hilgers, Reinhard; Viereck, Volker

    2010-07-01

    This study evaluates the relevance of the tape position and change in shape (tape functionality) under in vivo conditions for mid-term outcome. Changes in the sonographic tension-free vaginal tape (TVT) position relative to the percentage urethral length and the tape-urethra distance were determined after 6 and 48 months in 41 women with stress urinary incontinence. At 48 months, 76% (31/41) of women were cured, 17% (7/41) were improved, and 7% (3/41) were failures. Disturbed bladder voiding was present in 12% (5/41), de novo urge incontinence in 7% (3/41). The median TVT position was at 63% of urethral length. Median tape-urethra distance was 2.7 mm, ranging from 2.9 mm in continent patients without complications to 1.1 mm in those with obstructive complications. Patients with postoperative urine loss had a median distance of 3.9 mm. The tape was stretched at rest and C-shaped during straining in 15 of 41 women (37%) at 48 months (all continent). Patients with this tape functionality at 6 months were also cured at 48 months in 86% of cases (19/22), and only 14% (3/22) showed recurrent incontinence. Mid-term data suggest an optimal outcome if the tape is positioned at least 2 mm from the urethra at the junction of the middle and distal thirds. Patients with optimal tape functionality at 6 months are likely to show mid-term therapeutic success.

  13. Cache management of tape files in mass storage system

    International Nuclear Information System (INIS)

    Cheng Yaodong; Ma Nan; Yu Chuansong; Chen Gang

    2006-01-01

    This paper proposes the group-cooperative caching policy according to the characteristics of tapes and requirements of high energy physics domain. This policy integrates the advantages of traditional local caching and cooperative caching on basis of cache model. It divides cache into independent groups; the same group of cache is made of cooperating disks on network. This paper also analyzes the directory management, update algorithm and cache consistency of the policy. The experiment shows the policy can meet the requirements of data processing and mass storage in high energy physics domain very well. (authors)

  14. Measurement of velocity field in pipe with classic twisted tape using matching refractive index technique

    Energy Technology Data Exchange (ETDEWEB)

    Song, Min Seop; Park, So Hyun; Kim, Eung Soo [Seoul National Univ., Seoul (Korea, Republic of)

    2014-10-15

    Many researchers conducted experiments and numerical simulations to measure or predict a Nusselt number or a friction factor in a pipe with a twisted tape while some other studies focused on the heat transfer performance enhancement using various twisted tape configurations. However, since the optical access to the inner space of a pipe with a twisted tape was limited, the detailed flow field data were not obtainable so far. Thus, researchers mainly relied on the numerical simulations to obtain the data of the flow field. In this study, a 3D printing technique was used to manufacture a transparent test section for optical access. And also, a noble refractive index matching technique was used to eliminate optical distortion. This two combined techniques enabled to measure the velocity profile with Particle Image Velocimetry (PIV). The measured velocity field data can be used either to understand the fundamental flow characteristics around a twisted tape or to validate turbulence models in Computational Fluid Dynamics (CFD). In this study, the flow field in the test-section was measured for various flow conditions and it was finally compared with numerically calculated data. Velocity fields in a pipe with a classic twisted tape was measured using a particle image velocimetry (PIV) system. To obtain undistorted particle images, a noble optical technique, refractive index matching, was used and it was proved that high-quality image can be obtained from this experimental equipment. The velocity data from the PIV was compared with the CFD simulations.

  15. Numerical models of delamination behavior in 2G HTS tapes under transverse tension and peel

    Science.gov (United States)

    Duan, Yujie; Ta, Wurui; Gao, Yuanwen

    2018-02-01

    In extreme operating environments, delamination in 2G HTS tapes occurs within and/or near the superconductor layer from high transverse tensile stresses caused by fabrication, Lorentz forces and thermal mismatch, etc. Generally, transverse opening and peeling off are the main delamination modes, and are always studied in anvil and peel tests, respectively. Numerical models of these modes for 2G HTS tape are presented wherein the mixed-mode traction-separation law at the interface of the silver and superconductor layers is considered. Plastic deformations of copper, silver, and Hastelloy® in the HTS tape are taken into account. The results obtained from the transverse opening model show that the maximum average tensile stress is smaller than the delamination tensile strength because delamination is asynchronous in the tape. When a crack appears in the tape, only a small stress ( ≤ 1 MPa) is required to expand the crack to other stress free areas through peeling. Using the peeling model, the dependency of the peel strength on peeling angle is investigated under constant fracture toughness. Peel strength decreases with the peeling angle until the minimum value is reached at 150°, and thereafter increases slightly. Other results indicate that peel strength depends strongly on delamination strength, fracture toughness, and thickness of copper layer. The fracture toughness of the delamination interface, which is difficult to obtain by experiment, can be extracted using the present model.

  16. Measurement of velocity field in pipe with classic twisted tape using matching refractive index technique

    International Nuclear Information System (INIS)

    Song, Min Seop; Park, So Hyun; Kim, Eung Soo

    2014-01-01

    Many researchers conducted experiments and numerical simulations to measure or predict a Nusselt number or a friction factor in a pipe with a twisted tape while some other studies focused on the heat transfer performance enhancement using various twisted tape configurations. However, since the optical access to the inner space of a pipe with a twisted tape was limited, the detailed flow field data were not obtainable so far. Thus, researchers mainly relied on the numerical simulations to obtain the data of the flow field. In this study, a 3D printing technique was used to manufacture a transparent test section for optical access. And also, a noble refractive index matching technique was used to eliminate optical distortion. This two combined techniques enabled to measure the velocity profile with Particle Image Velocimetry (PIV). The measured velocity field data can be used either to understand the fundamental flow characteristics around a twisted tape or to validate turbulence models in Computational Fluid Dynamics (CFD). In this study, the flow field in the test-section was measured for various flow conditions and it was finally compared with numerically calculated data. Velocity fields in a pipe with a classic twisted tape was measured using a particle image velocimetry (PIV) system. To obtain undistorted particle images, a noble optical technique, refractive index matching, was used and it was proved that high-quality image can be obtained from this experimental equipment. The velocity data from the PIV was compared with the CFD simulations

  17. Density measurements of small amounts of high-density solids by a floatation method

    International Nuclear Information System (INIS)

    Akabori, Mitsuo; Shiba, Koreyuki

    1984-09-01

    A floatation method for determining the density of small amounts of high-density solids is described. The use of a float combined with an appropriate floatation liquid allows us to measure the density of high-density substances in small amounts. Using the sample of 0.1 g in weight, the floatation liquid of 3.0 g cm -3 in density and the float of 1.5 g cm -3 in apparent density, the sample densities of 5, 10 and 20 g cm -3 are determined to an accuracy better than +-0.002, +-0.01 and +-0.05 g cm -3 , respectively that correspond to about +-1 x 10 -5 cm 3 in volume. By means of appropriate degassing treatments, the densities of (Th,U)O 2 pellets of --0.1 g in weight and --9.55 g cm -3 in density were determined with an accuracy better than +-0.05 %. (author)

  18. Optimization of the tape placement process parameters for carbon–PPS composites

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Rietman, B.; Visser, Roy; Akkerman, Remko

    2013-01-01

    The interrelation between process parameters, material properties and interlaminar bond strength is investigated for the laser assisted tape placement process. Unidirectionally carbon reinforced poly(phenylene sulfide) (PPS) tapes were welded onto carbon woven fabric reinforced PPS laminates. The

  19. Leak isolation self-repairing tape for a water storage vessel and piping against holes

    International Nuclear Information System (INIS)

    Nagaya, Kosuke; Sekiguchi, Takahiro; Chen, Zhichao; Murakami, Iwanori

    2007-01-01

    A new type taping for a water storage vessel or piping is presented, in which water leakage is isolated automatically by its self-repairing mechanism against holes. The self-repairing unit (sealant layer) is consisting of three pieces of net with polymer particles inside lattices. Polymer particles, which expand their volume with water, is used for having self-repairing forces. In ordinary tapes, water leaks along the boundary between the tape and the vessel. In order to retain the leak isolation force, this article first discusses a method for making the sealant tape, then develops a method for fixing the sealant to the vessel. The portion of water leakage can be checked on this tape, and the method of detecting the hole or crack portion of the vessel is also presented by using the tape. (author)

  20. Silica frit formulation for low temperature co-fired ceramic tapes (LTCC)

    International Nuclear Information System (INIS)

    Nor Hayati Alias; Che Seman Mahmood

    2006-01-01

    Glassifier agents or so called fluxes could function to lower down the melting temperature of a ceramic material. Two types of silica based glass frits have been formulated to undergo vitrification at temperature lower than 1000 degree C. Frit A powder is composing of 11% Sodium Carbonate, 11% Calcium Oxide,15% Plumbum Oxide and 10% MgO while Frit B is composing of 12% Boron Oxide, 5% Ceria, 11% Sodium Carbonate and 2% Magnesium Oxide as glassifier agent in Silica powder. Two different ceramic slurries were made from a-alumina powder with addition of either Frit A or Frit B and also dispersant, binder and plasticizers, followed by casting into 0.04 mm thickness alumina green tapes. The tapes were then fired at temperature 1000 degree C to burn out plastic binder system and to vitrify the glass frits. Scanning Electron Microscopy (SEM)/EDX techniques were carried out to observe the changes in microstructure of the tape due to vitrication of glass frits. Comparisons were made with alumina green tapes without any glass frit component and with Commercial LTCC DuPont 951 tape. (Author)

  1. Study of the electric Held in HTS tape caused by perpendicular AC magnetic field

    International Nuclear Information System (INIS)

    Roiberg, V; Kopansky, F.

    2004-01-01

    Full Text: In a previous work we studied the influence of AC magnetic fields on voltage-currents (V-I) characteristics of high temperature superconducting (HTS) multi filament BSCC0-2223 tapes. It was found that AC magnetic fields perpendicular to the ab plane (the wide surface of the tape) cause a linear decrease of the critical current (IC) with amplitude of the AC magnetic field. The degradation of IC in .AC field was explained by the geometrical model according to which the transport current floe: is confined to the central zone of the tape where .AC field does not penetrate. For deeper understanding of the observed phenomena we carried out a study of the time dependence of the electric field during the cycle of AC field. At the same time we expanded the frequency range to low frequencies down to 1 Hz. The main results of the work are as following. 1. The time modulation of the electric field E in the HTS tape carrying transport DC current has the double frequency relating to AC magnetic field. 2. In field amplitudes less than 70 G the electric field modulation decreases with increasing frequency in opposite to its well-pronounced increase in higher AC field amplitudes. Alcove 70 G, the electric field increases with increasing the frequency of the external magnetic field. The wave forms of the electric field are different in both amplitudes ranges. 3. E-I curves of the tape in low amplitudes are frequency independent and coincide with E-l curves in AC field with intensity equal to the AC field amplitude. 4. In high AC field amplitudes, a strong dependence of the E-I curves on frequency is observed in the frequency range of 1-40 Hz and no dependence is observed in higher frequencies. Our results suggest that a combination of the geometrical model with flux creep concepts is necessary for a better understanding of the electric field behavior in our measurement conditions

  2. AC losses in horizontally parallel HTS tapes for possible wireless power transfer applications

    Science.gov (United States)

    Shen, Boyang; Geng, Jianzhao; Zhang, Xiuchang; Fu, Lin; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Gawith, James; Coombs, T. A.

    2017-12-01

    This paper presents the concept of using horizontally parallel HTS tapes with AC loss study, and the investigation on possible wireless power transfer (WPT) applications. An example of three parallel HTS tapes was proposed, whose AC loss study was carried out both from experiment using electrical method; and simulation using 2D H-formulation on the FEM platform of COMSOL Multiphysics. The electromagnetic induction around the three parallel tapes was monitored using COMSOL simulation. The electromagnetic induction and AC losses generated by a conventional three turn coil was simulated as well, and then compared to the case of three parallel tapes with the same AC transport current. The analysis demonstrates that HTS parallel tapes could be potentially used into wireless power transfer systems, which could have lower total AC losses than conventional HTS coils.

  3. Patient goals after tension free vaginal tape operation

    DEFF Research Database (Denmark)

    Glavind, Karin; Bjørk, Jonna; Kousgaard, Sabrina Just

    INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology and Obstetr......INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology...

  4. New concept for a compact tape transport system

    International Nuclear Information System (INIS)

    Mlekodaj, R.L.; Zganjar, E.F.; Cole, J.D.

    1980-01-01

    A new concept in tape transport systems for the collection and counting of radioactive samples from an on-line isotope separator has been developed. This new compact design was motivated by space limitations but important additional improvements over previous designs were made in cost, simplicity and vacuum quality. The system is based on a continuous loop of 6.5 millimeter wide recording tape 116 meters long with a conducting coating on one side for beam current monitoring. One small stepping motor is required for operation

  5. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    enhancement of heat transfer with twisted tape inserts as compared to plain ... studies for heat transfer and pressure drop of laminar flow in horizontal tubes ... flow in rectangular and square plain ducts and ducts with twisted-tape inserts .... presence of the insert in the pipe causes resistance to flow and increases turbulence.

  6. Research on high energy density plasmas and applications

    International Nuclear Information System (INIS)

    1999-01-01

    Recently, technologies on lasers, accelerators, and pulse power machines have been significantly advanced and input power density covers the intensity range from 10 10 W/cm 2 to higher than 10 20 W/cm 2 . As the results, high pressure gas and solid targets can be heated up to very high temperature to create hot dense plasmas which have never appeared on the earth. The high energy density plasmas opened up new research fields such as inertial confinement fusion, high brightness X-ray radiation sources, interiors of galactic nucleus,supernova, stars and planets, ultra high pressure condensed matter physics, plasma particle accelerator, X-ray laser, and so on. Furthermore, since these fields are intimately connected with various industrial sciences and technologies, the high energy density plasma is now studied in industries, government institutions, and so on. This special issue of the Journal of Plasma Physics and Nuclear Fusion Research reviews the high energy density plasma science for the comprehensive understanding of such new fields. In May, 1998, the review committee for investigating the present status and the future prospects of high energy density plasma science was established in the Japan Society of Plasma Science and Nuclear Fusion Research. We held three committee meetings to discuss present status and critical issues of research items related to high energy density plasmas. This special issue summarizes the understandings of the committee. This special issue consists of four chapters: They are Chapter 1: Physics important in the high energy density plasmas, Chapter 2: Technologies related to the plasma generation; drivers such as lasers, pulse power machines, particle beams and fabrication of various targets, Chapter 3: Plasma diagnostics important in high energy density plasma experiments, Chapter 4: A variety of applications of high energy density plasmas; X-ray radiation, particle acceleration, inertial confinement fusion, laboratory astrophysics

  7. Electrically conducting oxide buffer layers on biaxially textured nickel alloy tapes by reel-to-reel MOCVD process

    International Nuclear Information System (INIS)

    Stadel, O; Samoilenkov, S V; Muydinov, R Yu; Schmidt, J; Keune, H; Wahl, G; Gorbenko, O Yu; Korsakov, I E; Melnikov, O V; Kaul, A R

    2006-01-01

    Reel-to-reel MOCVD process for continuous growth of electrically conducting buffer layers on biaxially textured Ni5W tapes has been developed. The new buffer layer architechture is presented: 200 nm (La, Ba) 2 CuO 4 /40 nm (La, Ba)MnO 3 /Ni5W. Constituting layers with high structural quality have been grown on moving tapes (in plane FWHM ≤ 6 0 and out of plane FWHM ≤ 3 0 )

  8. The Influence of Solid-State Drawing on Mechanical Properties and Hydrolytic Degradation of Melt-Spun Poly(Lactic Acid (PLA Tapes

    Directory of Open Access Journals (Sweden)

    Fang Mai

    2015-12-01

    Full Text Available The influence of solid-state drawing on the morphology of melt-spun poly(l-lactic acid (PLLA tapes, and the accompanying changes in mechanical and degradation behaviour have been studied. Mechanical properties are found to be strongly dependent on both applied draw ratio and drawing temperature. Moduli of these highly oriented tapes are significantly increased compared to as-extruded tapes at both ambient and elevated temperatures. Interestingly, drawing leads to a significant increase in elongation to break (~3 times and toughness (~13 times compared to as-extruded tapes. Structural and morphological characterization indicates strain-induced crystallization as well as an increase in orientation of the crystalline phase at small strains. Upon further stretching, an “overdrawing” regime is observed, with decreased crystalline orientation due to the breakage of existing crystals. For fixed draw ratios, a significant increase in Young’s modulus and tensile strength is observed with increasing drawing temperature, due to a higher crystallinity and orientation obtained for tapes drawn at higher temperatures. FT-IR results indicate no crystal transformation after drawing, with the α-form being observed in all tapes. Hydrolytic degradability of PLLA was significantly reduced by solid-state drawing.

  9. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    Science.gov (United States)

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-14

    BACKGROUND It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). MATERIAL AND METHODS Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. RESULTS Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. CONCLUSIONS Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow.

  10. The effect of rigid taping with tension on mechanical displacement of the skin and change in pain perception.

    Science.gov (United States)

    Chen, Shu-Mei; Lo, Sing Kai; Cook, Jill

    2018-04-01

    To investigate the effect of rigid taping that induces mechanical displacement of the skin on pain perception. Single group experiment design with repeated measures. Twenty-three active healthy volunteers (12 men and 11 women) participated in the study. All participants received three different taping procedures: no tape, taping with tension, and taping without tension. The order of three taping conditions was randomised. Skin displacement was measured during taping with tension. A pressure algometer was used to measure the level of pain perception once before taping, and again after each taping condition, in one testing session. The participants were blind to the values of their pressure pain threshold (PPT) during the experimental period. The mean±SD skin displacement in the condition of taping with tension was 2.58±0.49cm. There were significant differences in PPT between taping with tension and taping without tension (mean difference (mean diff)±standard error (SE) 36.43±4.22kPa, p=0.000) and no tape (mean diff±SE 44.31±3.13kPa, p=0.000). No significant difference in PPT between no tape and taping without tension was found (mean diff±SE 7.88±2.83kPa, p=0.067). Taping with tension increases the threshold of pressure pain perception. Therefore, stretch and compression caused by rigid taping with tension could disturb the nociceptive signal transmission and alter pain perception. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  11. AC Application of HTS Conductors in Highly Dynamic Electric Motors

    International Nuclear Information System (INIS)

    Oswald, B; Best, K-J; Setzer, M; Duffner, E; Soell, M; Gawalek, W; Kovalev, L K

    2006-01-01

    Based on recent investigations we design highly dynamic electric motors up to 400 kW and linear motors up to 120 kN linear force using HTS bulk material and HTS tapes. The introduction of HTS tapes into AC applications in electric motors needs fundamental studies on double pancake coils under transversal magnetic fields. First theoretical and experimental results on AC field distributions in double-pancake-coils and corresponding AC losses will be presented. Based on these results the simulation of the motor performance confirms extremely high power density and efficiency of both types of electric motors. Improved characteristics of rare earth permanent magnets used in our motors at low temperatures give an additional technological benefit

  12. Standard Practice for Sampling for Particulate Contamination by Tape Lift

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This practice covers procedures for sampling surfaces to determine the presence of particulate contamination, 5 m and larger. The practice consists of the application of a pressure-sensitive tape to the surface followed by the removal of particulate contamination with the removal of the tape. The tape with the adhering particles is then mounted on counting slides. Counting and measuring of particles is done by standard techniques. 1.2 This practice describes the materials and equipment required to perform sampling of surfaces for particle counting and sizing. 1.3 The criteria for acceptance or rejection of a part for conformance to surface cleanliness level requirements shall be determined by the user and are not included in this practice. 1.4 This practice is for use on surfaces that are not damaged by the application of adhesive tape. The use of this practice on any surface of any material not previously tested or for which the susceptibility to damage is unknown is not recommended. In general, metal...

  13. Toward Low-Cost, High-Energy Density, and High-Power Density Lithium-Ion Batteries

    Science.gov (United States)

    Li, Jianlin; Du, Zhijia; Ruther, Rose E.; AN, Seong Jin; David, Lamuel Abraham; Hays, Kevin; Wood, Marissa; Phillip, Nathan D.; Sheng, Yangping; Mao, Chengyu; Kalnaus, Sergiy; Daniel, Claus; Wood, David L.

    2017-09-01

    Reducing cost and increasing energy density are two barriers for widespread application of lithium-ion batteries in electric vehicles. Although the cost of electric vehicle batteries has been reduced by 70% from 2008 to 2015, the current battery pack cost (268/kWh in 2015) is still >2 times what the USABC targets (125/kWh). Even though many advancements in cell chemistry have been realized since the lithium-ion battery was first commercialized in 1991, few major breakthroughs have occurred in the past decade. Therefore, future cost reduction will rely on cell manufacturing and broader market acceptance. This article discusses three major aspects for cost reduction: (1) quality control to minimize scrap rate in cell manufacturing; (2) novel electrode processing and engineering to reduce processing cost and increase energy density and throughputs; and (3) material development and optimization for lithium-ion batteries with high-energy density. Insights on increasing energy and power densities of lithium-ion batteries are also addressed.

  14. Self-field AC losses in Bi-2223 superconducting tapes

    International Nuclear Information System (INIS)

    Mueller, K. H.; Leslie, K.E.

    1996-01-01

    Full text: The self-field AC loss in Bi-2223 silver sheathed tapes for AC currents of up to 100 A was measured at 77 K and frequencies of 60 Hz and 600 Hz using a lock-in amplifier. The frequency dependence indicated a purely hysteretic loss which can be well described in terms of the critical state model for a flat superconducting strip. The only parameter needed to predict the self-field AC loss is the critical current of the critical state. Because the loss voltage is extremely small compared with the inductive voltage, a very high accuracy of the lock-in amplifier phase setting is required. Unlike in loss measurements on cylindrical superconducting samples, in the case of the tape the measuring circuit leads have to be brought out from the surface forming a loop where the changing magnetic field induces an additional voltage. Only if the loop formed by the leads at the voltage tabs is large enough will the apparent power dissipation approach the real AC loss associated with the length of the sample probed

  15. Properties of matter at ultra-high densities

    International Nuclear Information System (INIS)

    Banerjee, B.; Chitre, S.M.

    1975-01-01

    The recent discovery of pulsars and their subsequent identification with neutron stars has given a great impetus to the study of the behaviour of matter at ultra high densities. The object of these studies is to calculate the equation of state as a function of density. In this paper, the properties of electrically neutral, cold (T=0) matter at unusually high densities has been reviewed. The physics of the equation of state of such matter divides quite naturally in four density ranges. (i) At the very lowest densities the state of minimum energy is a lattice of 56 Fe atoms. This state persists upto 10 7 g/cm 3 . (ii) In the next density region the nuclei at the lattice sites become neutron rich because the high electron Fermi energy makes inverse beta decay possible. (iii) At a density 4.3 x 10 11 the nuclei become so neutron rich that the neutrons start 'dripping' out of the nuclei and form a gas. This density range is characterised by large, neutron-rich nuclei immersed in a neutron gas. (iv) At a density 2.4 x 10 14 g/cm 3 , the nuclei disappear and a fluid of uniform neutron matter with a small percentage of protons and electrons results. The above four density ranges have been discussed in detail as the equation of state is now well established upto the nuclear density 3 x 10 14 g/cm 3 . The problems of extending the equation of state beyond this density are also touched upon. (author)

  16. High-field dipoles for future accelerators

    International Nuclear Information System (INIS)

    Wipf, S.L.

    1984-09-01

    This report presents the concept for building superconducting accelerator dipoles with record high fields. Economic considerations favor the highest possible current density in the windings. Further discussion indicates that there is an optimal range of pinning strength for a superconducting material and that it is not likely for multifilamentary conductors to ever equal the potential performance of tape conductors. A dipole design with a tape-wound, inner high-field winding is suggested. Methods are detailed to avoid degradation caused by flux jumps and to overcome problems with the dipole ends. Concerns for force support structure and field precision are also addressed. An R and D program leading to a prototype 11-T dipole is outlined. Past and future importance of superconductivity to high-energy physics is evident from a short historical survey. Successful dipoles in the 10- to 20-T range will allow interesting options for upgrading present largest accelerators

  17. Experimental validation of tape springs to be used as thin-walled space structures

    Science.gov (United States)

    Oberst, S.; Tuttle, S. L.; Griffin, D.; Lambert, A.; Boyce, R. R.

    2018-04-01

    With the advent of standardised launch geometries and off-the-shelf payloads, space programs utilising nano-satellite platforms are growing worldwide. Thin-walled, flexible and self-deployable structures are commonly used for antennae, instrument booms or solar panels owing to their lightweight, ideal packaging characteristics and near zero energy consumption. However their behaviour in space, in particular in Low Earth Orbits with continually changing environmental conditions, raises many questions. Accurate numerical models, which are often not available due to the difficulty of experimental testing under 1g-conditions, are needed to answer these questions. In this study, we present on-earth experimental validations, as a starting point to study the response of a tape spring as a representative of thin-walled flexible structures under static and vibrational loading. Material parameters of tape springs in a singly (straight, open cylinder) and a doubly curved design, are compared to each other by combining finite element calculations, with experimental laser vibrometry within a single and multi-stage model updating approach. While the determination of the Young's modulus is unproblematic, the damping is found to be inversely proportional to deployment length. With updated material properties the buckling instability margin is calculated using different slenderness ratios. Results indicate a high sensitivity of thin-walled structures to miniscule perturbations, which makes proper experimental testing a key requirement for stability prediction on thin-elastic space structures. The doubly curved tape spring provides closer agreement with experimental results than a straight tape spring design.

  18. Control program for punched paper tape for the PDP-8/1 computer

    International Nuclear Information System (INIS)

    German, U.

    1976-01-01

    A program was developed for the PDP-8/1 computer to control the punched paper tape supplied by the measuring instruments. Any departure from the program is detected by an optical reader which stops the tape and displays the error on an accumulator. This program which is suitable for large amounts of data punched on paper tape has been in use at the Beer-Sheva laboratories for detecting errors in the sample changing operation. (B.G.)

  19. Fabrication and properties of Ag-Bi2223 tapes with resistive barriers for filament decoupling

    International Nuclear Information System (INIS)

    Inada, Ryoji; Fukumoto, Yohei; Yasunami, Taeko; Nakamura, Yuichi; Oota, Akio; Li Chengshang; Zhang Pingxiang

    2007-01-01

    In this paper, we prepared the Bi2223 multifilamentary tapes with Ca 2 CuO 3 + Bi2212 as interfilamentary resistive barriers to suppress the electromagnetic coupling among the filaments under AC external magnetic field. The tapes with thin barrier layers of Ca 2 CuO 3 + 30 wt% Bi2212 around the filaments were prepared by using a standard powder-in-tube (PIT) method. The outside surface of monocore Ag-sheathed rods was coated by barrier materials. Then, the several coated monocore wires were stacked and packed into another Ag or Ag-Mg alloy tube. The packed tube was drawn and rolled into tape shape. The tape was subsequently sintered to form Bi2223 phase inside filaments. For the characterization of tapes, X-ray diffraction measurements were performed to investigate the phase formation inside the filaments. The uniformity of transport properties (J c ) for barrier tapes were evaluated on the order of several metre lengths and compared with the result for the tapes without barriers. Finally, AC loss characteristics under AC parallel transverse magnetic field were investigated to examine the effect of introducing the barriers on the filament decoupling

  20. Is application of Kinesio tape to treat hyperlordosis more effective on abdominal muscles or hamstrings?

    Directory of Open Access Journals (Sweden)

    Sara Abolahrari Shirazi

    2018-01-01

    Full Text Available Background: Hyperlordosis is defined as an abnormal increase in the lumbar arch of >40°. This study compared two taping techniques include abdominal muscles and hamstrings taping for the treatment of lumbar hyperlordosis. Materials and Methods: The randomized clinical trial was performed in Shiraz, Iran, during June and September 2014. Thirty women aged 20–45 years old with at least 40° lumbar lordosis participated. The women were randomized into two groups (n = 15. Abdominal muscles taping was performed for the first group, whereas the other group underwent hamstrings taping with 30% tension. Lumbar lordosis was measured before, immediately after, and 24 h after taping. The two-way repeated measures analysis of variance was used to compare the two groups for lumbar lordosis angle. Results: No significant differences were detected between the lumbar lordosis angles before and immediately after taping in the two groups (P > 0.05. However, a significant reduction was observed in lordosis angle in the abdominal group and the hamstring group 24 h after taping relative to before intervention (P < 0.01. Conclusion: Taping of the abdominal and hamstring muscles was not effective immediately, whereas it decreased lordosis after 24 h.

  1. High-density carbon ablator ignition path with low-density gas-filled rugby hohlraum

    International Nuclear Information System (INIS)

    Amendt, Peter; Ho, Darwin D.; Jones, Ogden S.

    2015-01-01

    A recent low gas-fill density (0.6 mg/cc 4 He) cylindrical hohlraum experiment on the National Ignition Facility has shown high laser-coupling efficiency (>96%), reduced phenomenological laser drive corrections, and improved high-density carbon capsule implosion symmetry [Jones et al., Bull. Am. Phys. Soc. 59(15), 66 (2014)]. In this Letter, an ignition design using a large rugby-shaped hohlraum [Amendt et al., Phys. Plasmas 21, 112703 (2014)] for high energetics efficiency and symmetry control with the same low gas-fill density (0.6 mg/cc 4 He) is developed as a potentially robust platform for demonstrating thermonuclear burn. The companion high-density carbon capsule for this hohlraum design is driven by an adiabat-shaped [Betti et al., Phys. Plasmas 9, 2277 (2002)] 4-shock drive profile for robust high gain (>10) 1-D ignition performance and large margin to 2-D perturbation growth

  2. High-density carbon ablator ignition path with low-density gas-filled rugby hohlraum

    Science.gov (United States)

    Amendt, Peter; Ho, Darwin D.; Jones, Ogden S.

    2015-04-01

    A recent low gas-fill density (0.6 mg/cc 4He) cylindrical hohlraum experiment on the National Ignition Facility has shown high laser-coupling efficiency (>96%), reduced phenomenological laser drive corrections, and improved high-density carbon capsule implosion symmetry [Jones et al., Bull. Am. Phys. Soc. 59(15), 66 (2014)]. In this Letter, an ignition design using a large rugby-shaped hohlraum [Amendt et al., Phys. Plasmas 21, 112703 (2014)] for high energetics efficiency and symmetry control with the same low gas-fill density (0.6 mg/cc 4He) is developed as a potentially robust platform for demonstrating thermonuclear burn. The companion high-density carbon capsule for this hohlraum design is driven by an adiabat-shaped [Betti et al., Phys. Plasmas 9, 2277 (2002)] 4-shock drive profile for robust high gain (>10) 1-D ignition performance and large margin to 2-D perturbation growth.

  3. High-density carbon ablator ignition path with low-density gas-filled rugby hohlraum

    Energy Technology Data Exchange (ETDEWEB)

    Amendt, Peter; Ho, Darwin D.; Jones, Ogden S. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)

    2015-04-15

    A recent low gas-fill density (0.6 mg/cc {sup 4}He) cylindrical hohlraum experiment on the National Ignition Facility has shown high laser-coupling efficiency (>96%), reduced phenomenological laser drive corrections, and improved high-density carbon capsule implosion symmetry [Jones et al., Bull. Am. Phys. Soc. 59(15), 66 (2014)]. In this Letter, an ignition design using a large rugby-shaped hohlraum [Amendt et al., Phys. Plasmas 21, 112703 (2014)] for high energetics efficiency and symmetry control with the same low gas-fill density (0.6 mg/cc {sup 4}He) is developed as a potentially robust platform for demonstrating thermonuclear burn. The companion high-density carbon capsule for this hohlraum design is driven by an adiabat-shaped [Betti et al., Phys. Plasmas 9, 2277 (2002)] 4-shock drive profile for robust high gain (>10) 1-D ignition performance and large margin to 2-D perturbation growth.

  4. Numerical Modeling of the Side Flow in Tape Casting of a Non-Newtonian Fluid

    DEFF Research Database (Denmark)

    Jabbari, Masoud; Hattel, Jesper Henri

    2013-01-01

    in the tape casting process is modeled numerically with ANSYS FLUENT in combination with an Ostwald-de Waele power law constitutive equation. Based on rheometer experiments, the constants in the Ostwald-de Waele power law are identified for the considered LSM material and applied in the numerical modeling......One of the most common ways used to produce multilayer ceramics (MLC) is tape casting. In this process, the dried tape thickness is of great interest to control the desired products and applications. One of the parameters that influences the final tape thickness is the side flow factor (a) which...... is mostly measured at the end of the process by a volumetric comparison of the tape which flowed outside the casting width to the tape within the casting width. This phenomenon has not been predicted theoretically yet in the literature. In this study, the flow of (La0.85Sr0.15)0.9MnO3 (LSM) slurry...

  5. Effects of functional taping compared with sham taping and minimal intervention on pain intensity and static postural control for patients with non-specific chronic low back pain: a randomised clinical trial protocol.

    Science.gov (United States)

    Jassi, F J; Del Antônio, T; Moraes, R; George, S Z; Chaves, T C

    2017-06-01

    To investigate the immediate and 1-month effects of functional taping to lumbar spine for pain intensity and postural control in patients with chronic non-specific low back pain. Randomised clinical trial. One hundred and twenty participants aged 18 to 50 years. Participants will be allocated at random to receive one of three interventions: functional star-shape taping for 7 days, sham functional taping for 7 days or minimal intervention, one session. The primary outcomes will be pain intensity and postural control. Four measurements of static posturography will be conducted: pre-intervention, immediately after application of the tape, 7 days post-intervention (after removal of the tape) and 1-month follow-up. The secondary outcomes will be low-back-pain-related disability, global perceived effect of treatment and fear avoidance beliefs. Primary and secondary outcomes will be assessed on three occasions: pre-intervention, 7 days post-intervention and at 1-month follow-up. All statistical analyses will be conducted following intention-to-treat principles, and the treatment effects will be calculated using linear mixed models. The results of this study will determine the effects of functional taping on pain intensity and postural control compared with sham taping and minimal intervention. NCT02546466. Copyright © 2016 Chartered Society of Physiotherapy. All rights reserved.

  6. High-temperature superconducting conductors and cables

    International Nuclear Information System (INIS)

    Peterson, D.E.; Maley, M.P.; Boulaevskii, L.; Willis, J.O.; Coulter, J.Y.; Ullmann, J.L.; Cho, Jin; Fleshler, S.

    1996-01-01

    This is the final report of a 3-year LDRD project at LANL. High-temperature superconductivity (HTS) promises more efficient and powerful electrical devices such as motors, generators, and power transmission cables; however this depends on developing HTS conductors that sustain high current densities J c in high magnetic fields at temperatures near liq. N2's bp. Our early work concentrated on Cu oxides but at present, long wire and tape conductors can be best made from BSCCO compounds with high J c at low temperatures, but which are degraded severely at temperatures of interest. This problem is associated with thermally activated motion of magnetic flux lines in BSCCO. Reducing these dc losses at higher temperatures will require a high density of microscopic defects that will pin flux lines and inhibit their motion. Recently it was shown that optimum defects can be produced by small tracks formed by passage of energetic heavy ions. Such defects result when Bi is bombarded with high energy protons. The longer range of protons in matter suggests the possibility of application to tape conductors. AC losses are a major limitation in many applications of superconductivity such as power transmission. The improved pinning of flux lines reduces ac losses, but optimization also involves other factors. Measuring and characterizing these losses with respect to material parameters and conductor design is essential to successful development of ac devices

  7. TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

    Science.gov (United States)

    Hubka, Petr; Nanka, Ondrej; Masata, Jaromir; Martan, Alois; Svabik, Kamil

    2016-07-01

    The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.

  8. High-Throughput Method of Whole-Brain Sectioning, Using the Tape-Transfer Technique.

    Science.gov (United States)

    Pinskiy, Vadim; Jones, Jamie; Tolpygo, Alexander S; Franciotti, Neil; Weber, Kevin; Mitra, Partha P

    2015-01-01

    Cryostat sectioning is a popular but labor-intensive method for preparing histological brain sections. We have developed a modification of the commercially available CryoJane tape collection method that significantly improves the ease of collection and the final quality of the tissue sections. The key modification involves an array of UVLEDs to achieve uniform polymerization of the glass slide and robust adhesion between the section and slide. This report presents system components and detailed procedural steps, and provides examples of end results; that is, 20 μm mouse brain sections that have been successfully processed for routine Nissl, myelin staining, DAB histochemistry, and fluorescence. The method is also suitable for larger brains, such as rat and monkey.

  9. Modelling of fluid flow in tape casting of thin ceramics: Analytical approaches and numerical investigations

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Many startup products such as multilayered inductors, multilayered varistors, piezoelectrics, ceramic fuel cells and lithium ion battery...... components are dependent upon tape casting technology. One of the growing sciences in the processing of ceramics by tape casting is the use of fluid flow analysis to control and enhance the final tapes. The fluid dynamics analysis of the ceramic slurries during tape casting is an efficient mean to elucidate...... the physical parameters crucial to the process. A review of the development of the tape casting process with particular focus on modelling the material flow is presented and in this context the current status is examined and future potential discussed....

  10. Particle image velocimetry measurements of 2-dimensional velocity field around twisted tape

    Energy Technology Data Exchange (ETDEWEB)

    Song, Min Seop; Park, So Hyun; Kim, Eung Soo, E-mail: kes7741@snu.ac.kr

    2016-11-01

    Highlights: • Measurements of the flow field in a pipe with twisted tape were conducted by particle image velocimetry (PIV). • A novel matching index of refraction technique utilizing 3D printing and oil mixture was adopted to make the test section transparent. • Undistorted particle images were clearly captured in the presence of twisted tape. • 2D flow field in the pipe with twisted tape revealed the characteristic two-peak velocity profile. - Abstract: Twisted tape is a passive component used to enhance heat exchange in various devices. It induces swirl flow that increases the mixing of fluid. Thus, ITER selected the twisted tape as one of the candidates for turbulence promoting in the divertor cooling. Previous study was mainly focused on the thermohydraulic performance of the twisted tape. As detailed data on the velocity field around the twisted tape was insufficient, flow visualization study was performed to provide fundamental data on velocity field. To visualize the flow in a complex structure, novel matching index of refraction technique was used with 3-D printing and mixture of anise and mineral oil. This technique enables the camera to capture undistorted particle image for velocity field measurement. Velocity fields at Reynolds number 1370–9591 for 3 different measurement plane were obtained through particle image velocimetry. The 2-dimensional averaged velocity field data were obtained from 177 pair of instantaneous velocity fields. It reveals the characteristic two-peak flow motion in axial direction. In addition, the normalized velocity profiles were converged with increase of Reynolds numbers. Finally, the uncertainty of the result data was analyzed.

  11. Methods for tape fabrication of continuous filament composite parts and articles of manufacture thereof

    Science.gov (United States)

    Weisberg, Andrew H

    2013-10-01

    A method for forming a composite structure according to one embodiment includes forming a first ply; and forming a second ply above the first ply. Forming each ply comprises: applying a bonding material to a tape, the tape comprising a fiber and a matrix, wherein the bonding material has a curing time of less than about 1 second; and adding the tape to a substrate for forming adjacent tape winds having about a constant distance therebetween. Additional systems, methods and articles of manufacture are also presented.

  12. IMMEDIATE EFFECT OF KINESIO VERSUS MCCONNELL TAPING ON PATELLOFEMORAL PAIN SYNDROME DURING FUNCTIONAL ACTIVITIES- A COMPARATIVE STUDY

    Directory of Open Access Journals (Sweden)

    Sai Kumar. N

    2015-12-01

    Full Text Available Background: Patellofemoral pain syndrome (PFPS is a condition presenting with anterior knee pain or pain behind the patella (retro-patellar pain. The purpose of the study is to find the immediate effect of Kinesio taping versus McConnell taping in patellofemoral pain syndrome subjects during functional activities- stair ascent, stair descent and squat lift. Methods: An experimental study design with three groups, 45 subjects with patellofemoral pain syndrome was randomized. 15 subjects into each Kinesiotaping group, McConnell group and Sham group. Kinesiotaping group received patellofemoral kinesio taping technique, McConnell group received McConnell taping technique and Sham group received sham taping technique. Outcome measure pain was measured using visual analogue scale during pre and post taping pain levels that were measured during three functional activities: stair ascent, stair descent and squat lift. Results: When analysed within the group using paired ‘t’ test and wilcoxon signed rank test, there is statistically significant improvement in post pain levels in KT, MT and Sham group during stair climbing, stair descent and squat lift. When compared measuring of pre and post pain levels between three groups, there is no significant change in pain level between Kinesio taping and McConnell taping as also compared to sham taping. Conclusion: The study concluded that Kinesio taping, McConnell taping and sham taping shown immediate effect on reducing pain during functional activities such as stair climbing, stair descent and squat lift with greater percentage of pain reduction was found following Kinesiotaping and McConnell taping.

  13. Photoionization and High Density Gas

    Science.gov (United States)

    Kallman, T.; Bautista, M.; White, Nicholas E. (Technical Monitor)

    2002-01-01

    We present results of calculations using the XSTAR version 2 computer code. This code is loosely based on the XSTAR v.1 code which has been available for public use for some time. However it represents an improvement and update in several major respects, including atomic data, code structure, user interface, and improved physical description of ionization/excitation. In particular, it now is applicable to high density situations in which significant excited atomic level populations are likely to occur. We describe the computational techniques and assumptions, and present sample runs with particular emphasis on high density situations.

  14. Temporary ectropion therapy by adhesive taping: a case study

    Directory of Open Access Journals (Sweden)

    Habermann Anke

    2008-07-01

    Full Text Available Abstract Introduction Various surgical procedures are available to correct paralytic ectropion, which are applied in irreversible facial paresis. Problems occur when facial paresis has an unclear prognosis, since surgery of the lower eyelid is usually irreversible. We propose a simple method to correct temporary ectropion in facial palsy by applying an adhesive strip. Patients and methods Ten patients with peripheral facial paresis and paralytic ectropion were treated with an adhesive strip to correct paralytic ectropion. We used "Steri-Strips" (45 × 6.0 mm, which were taped on the carefully cleaned skin of the lower eyelid and of the adjacent zygomatic region until the prognosis of the paresis was clarified. In addition to the examiner's evaluation of the lower lacrimal point in the lacrimal lake, subjective improvement of the symptoms was assessed using a visual analogue scale (VAS, 1–10. Results 9 patients reported a clear improvement of the symptoms after adhesive taping. There was a clear regression of tearing (VAS (median = 8; 1 = no improvement, 10 = very good improvement, the cosmetic impairment of the adhesive tape was low (VAS (median = 2.5; 1 = no impairment, 10 = severe impairment and most of the patients found the use of the adhesive strip helpful. There was slight reddening of the skin in one case and well tolerated by the facial skin in the other cases. Conclusion The cause and location of facial nerve damage are decisive for the type of surgical therapy. In potentially reversible facial paresis, procedures should be used that are easily performed and above all reversible without complications. Until a reliable prognosis of the paresis can be made, adhesive taping is suited for the temporary treatment of paralytic ectropion. Adhesive taping is simple and can be performed by the patient.

  15. Technical and economical evaluation of tape drip and drip line irrigation systems in a strawberry greenhouse

    Directory of Open Access Journals (Sweden)

    Soghra HOSSEINIAN

    2016-04-01

    Full Text Available This study was done in a strawberry greenhouse to examine the technical and the economical evaluation of two drip irrigation systems including the tape and the drip line in the northern part of Iran. The result showed that all of the technical indices with tape were higher than drip line, and due to statistical analysis reveal a significant difference (P < 0.05. Yield and water productivity (WP with tape were higher than drip line (P < 0.05. Benefit per drop (BPD and net benefit per drop (NBPD with tape were higher than drip line. Net present value, internal rate of capital return and benefit to cost ratio in drip line were higher than tape. In general, regarding technical evaluation tape was better than drip line, besides according to the economical evaluation the drip ­lines were better than tape.

  16. Elongated grains in cube textured nickel substrate tapes and flat wires

    International Nuclear Information System (INIS)

    Eickemeyer, J; Gueth, A; Holzapfel, B

    2008-01-01

    Cube textured nickel substrate tapes and flat wires with an increased grain aspect ratio were prepared from nickel micro-alloyed with silver plus yttrium and silver, respectively. Whereas the maximum grain aspect ratio for the tapes was about 6, this value reached up to 14 for the flat wires

  17. Electronic DC transformer with high power density

    NARCIS (Netherlands)

    Pavlovský, M.

    2006-01-01

    This thesis is concerned with the possibilities of increasing the power density of high-power dc-dc converters with galvanic isolation. Three cornerstones for reaching high power densities are identified as: size reduction of passive components, reduction of losses particularly in active components

  18. Dependences of microstructure and critical current density on the thickness of YBa2Cu3O7-x film prepared by pulsed laser deposition on buffered Ni–W tape

    International Nuclear Information System (INIS)

    Xu, Da; Wang, Ying; Liu, Linfei; Li, Yijie

    2013-01-01

    YBa 2 Cu 3 O 7−x (YBCO) films with different thicknesses were fabricated on buffered Ni–W tapes by pulsed laser deposition. The thickness dependences of microstructure and critical current density (J c ) of YBCO film were systematically investigated. The microstructure and surface morphology of YBCO film were characterized by X-ray diffraction, optical microscopy, field emission scanning electron microscopy and atomic force microscopy. And the critical current (I c ) of YBCO film was measured by the conventional four-probe method. We found that the full width at half maximum values of both omega and phi scan rocking curves, the content of a-axis oriented grain, and surface roughness of YBCO film all increased with augmenting the thickness of YBCO film. It was also found that with increasing the thickness of YBCO film from 0.3 μm to 1.5 μm, the I c of YBCO film increased from 72 A/cm to 248 A/cm and yet J c of YBCO film decreased from 2.1 × 10 6 A/cm 2 to 1.6 × 10 6 A/cm 2 . Our results indicated that the microstructure and J c of YBCO film were largely dependent on the thickness of YBCO film under the optimized deposition condition of substrate temperature. - Highlights: ► YBa 2 Cu 3 O 7−x (YBCO) films with different thicknesses were grown on metallic tapes. ► The texture and critical current were dependent on the thickness of YBCO film. ► Thickness effect was weakened by fabricating YBCO film layer by layer

  19. TAPE CALENDERING MANUFACTURING PROCESS FOR MULTILAYER THIN-FILM SOLID OXIDE FUEL CELLS

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen Minh; Kurt Montgomery

    2004-10-01

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC during the Phases I and II under Contract DE-AC26-00NT40705 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Tape Calendering Manufacturing Process For Multilayer Thin-Film Solid Oxide Fuel Cells''. The main objective of this project was to develop the manufacturing process based on tape calendering for multilayer solid oxide fuel cells (SOFC's) using the unitized cell design concept and to demonstrate cell performance under specified operating conditions. Summarized in this report is the development and improvements to multilayer SOFC cells and the unitized cell design. Improvements to the multilayer SOFC cell were made in electrochemical performance, in both the anode and cathode, with cells demonstrating power densities of nearly 0.9 W/cm{sup 2} for 650 C operation and other cell configurations showing greater than 1.0 W/cm{sup 2} at 75% fuel utilization and 800 C. The unitized cell design was matured through design, analysis and development testing to a point that cell operation at greater than 70% fuel utilization was demonstrated at 800 C. The manufacturing process for both the multilayer cell and unitized cell design were assessed and refined, process maps were developed, forming approaches explored, and nondestructive evaluation (NDE) techniques examined.

  20. Study on the performance improvement of the high temperature superconducting coil with several separated coils at the edges

    International Nuclear Information System (INIS)

    Ishiguri, S.; Oka, T.; Fukui, S.; Ogawa, J.; Sato, T.

    2008-01-01

    In designing high temperature superconducting (HTS) coils, it is important to secure large magnetic fields and stored energy using shorter tape length. Thus, it is necessary to improve the transport current performance of the coils. The critical current and n-value of an HTS tape depend on magnetic fields and flux angles under constant temperature. Considering these dependencies, we established a model to analyze coil critical current. This model clarifies that relatively large electric fields are generated at the coil edges. This adversely affects the transport current performance. In this study, the coil edge is separated into several coils, keeping the total tape length constant. This increases the coil critical current, stored energy, central magnetic field, and also the coil volume, which contains vacancies created by the separation. To estimate coil performance, we calculated the stored energy density, whose denominator is the increased coil volume. This stored energy density reaches its maximum value when the number of the separated coils is eight. At this optimum separation, the central magnetic field increases by 13%, and the stored energy improves by 43%, compared to a rectangular coil wound with the same tape length

  1. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  2. Estimation of hysteretic losses for MgB2 tapes under the operating conditions of a generator

    Science.gov (United States)

    Vargas-Llanos, Carlos Roberto; Zermeño, Víctor M. R.; Sanz, Santiago; Trillaud, Frederic; Grilli, Francesco

    2016-03-01

    Hysteretic losses in the MgB2 wound superconducting coils of a 550 kW synchronous hybrid scaled generator were estimated as part of the European project SUPRAPOWER led by the Spanish Fundación Tecnalia Research & Innovation. Particular interest was given to the losses caused by the magnetic flux ripples in the rotor coils originating from the conventional stator during nominal operation. To compute these losses, a 2D finite element analysis was conducted and Maxwell’s equations written in the H-formulation were solved considering the nonlinear material properties of the conductor materials. The modeled tapes are made of multiple MgB2 filaments embedded in a Ni matrix and soldered to a high purity copper strip and insulated with Dacron braid. Three geometrical models of single tape cross sections of decreasing complexity were studied: (1) the first model reproduced closely the actual cross section obtained from tape micrographs. (2) The second model was obtained from the computed elasto-plastic deformation of a round Ni wire. (3) The third model was based on a simplified cross section with the superconducting filaments bundled in a single elliptical bulky structure. The last geometry allowed the validation of the modeling technique by comparing numerical losses with results from well-established analytical expressions. Additionally, the following cases of filament transpositions of the multi-filamentary tape were studied: no transposition, partial and full transposition; thereby improving understanding of the relevance of the tape fabrication process on the magnitude of the determination of ac losses. Finally, choosing the right level of geometrical detail, the following operational regimes of the machine and its impact on individual superconducting tape losses in the rotor were studied: bias-dc current, ramping current under ramping background field and magnetic flux ripples under dc background current and field.

  3. Estimation of hysteretic losses for MgB2 tapes under the operating conditions of a generator

    International Nuclear Information System (INIS)

    Vargas-Llanos, Carlos Roberto; Zermeño, Víctor M R; Grilli, Francesco; Sanz, Santiago; Trillaud, Frederic

    2016-01-01

    Hysteretic losses in the MgB 2 wound superconducting coils of a 550 kW synchronous hybrid scaled generator were estimated as part of the European project SUPRAPOWER led by the Spanish Fundación Tecnalia Research and Innovation. Particular interest was given to the losses caused by the magnetic flux ripples in the rotor coils originating from the conventional stator during nominal operation. To compute these losses, a 2D finite element analysis was conducted and Maxwell’s equations written in the H-formulation were solved considering the nonlinear material properties of the conductor materials. The modeled tapes are made of multiple MgB 2 filaments embedded in a Ni matrix and soldered to a high purity copper strip and insulated with Dacron braid. Three geometrical models of single tape cross sections of decreasing complexity were studied: (1) the first model reproduced closely the actual cross section obtained from tape micrographs. (2) The second model was obtained from the computed elasto-plastic deformation of a round Ni wire. (3) The third model was based on a simplified cross section with the superconducting filaments bundled in a single elliptical bulky structure. The last geometry allowed the validation of the modeling technique by comparing numerical losses with results from well-established analytical expressions. Additionally, the following cases of filament transpositions of the multi-filamentary tape were studied: no transposition, partial and full transposition; thereby improving understanding of the relevance of the tape fabrication process on the magnitude of the determination of ac losses. Finally, choosing the right level of geometrical detail, the following operational regimes of the machine and its impact on individual superconducting tape losses in the rotor were studied: bias-dc current, ramping current under ramping background field and magnetic flux ripples under dc background current and field. (paper)

  4. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process

    Science.gov (United States)

    Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-01

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing. PMID:29385048

  5. Spontaneous magnetization in high-density quark matter

    DEFF Research Database (Denmark)

    Tsue, Yasuhiko; da Providência, João; Providência, Constanca

    2015-01-01

    It is shown that spontaneous magnetization occurs due to the anomalous magnetic moments of quarks in high-density quark matter under the tensor-type four-point interaction. The spin polarized condensate for each flavor of quark appears at high baryon density, which leads to the spontaneous magnet...

  6. Conductive sub-layer of twisted-tape-induced swirl-flow heat transfer in vertical circular tubes with various twisted-tape inserts

    Science.gov (United States)

    Hata, K.; Fukuda, K.; Masuzaki, S.

    2018-04-01

    Twisted-tape-induced swirl-flow heat transfer due to exponentially increasing heat inputs with various exponential periods ( Q = Q 0 exp(t/τ), τ = 6.04 to 23.07 s) and twisted-tape-induced pressure drop was systematically measured for various mass velocities ( G = 4115 to 13,656 kg/m2 s), inlet liquid temperatures ( T in = 285.88 to 299.09 K), and inlet pressures ( P in = 847.45 to 943.29 kPa) using an experimental water loop flow. Measurements were made over a 59.2-mm effective length and three sections (upper, middle, and lower positions), within which four potential taps were spot-welded onto the outer surface of a 6-mm-inner-diameter, 69.6-mm-heated length, 0.4-mm-thickness platinum circular test tube. Type SUS304 twisted tapes with a width w = 5.6 mm, a thickness δ T = 0.6 mm, a total length l = 372 mm, and twist ratios y = 2.39 and 4.45 were employed in this study. The RANS equations (Reynolds Averaged Navier-Stokes Simulation) with a k-ɛ turbulence model for a circular tube 6 mm in diameter and 636 mm in length were numerically solved for heating of water with a heated section 6 mm in diameter and 70 mm in length using the CFD code, under the same conditions as the experimental ones and considering the temperature dependence of the thermo-physical properties concerned. The theoretical values of surface heat flux q on the circular tubes with twisted tapes with twist ratios y of 2.39 and 4.45 were found to be almost in agreement with the corresponding experimental values of heat flux q, with deviations of less than 30% for the range of temperature difference between the average heater inner surface temperature and the liquid bulk mean temperature ΔT L [ = T s,av - T L , T L = ( T in + T out )/2] considered in this study. The theoretical values of the local surface temperature T s , local average liquid temperature T f,av , and local liquid pressure drop ΔP x were found to be within almost 15% of the corresponding experimental ones. The thickness of the

  7. High Energy Density Sciences with High Power Lasers at SACLA

    Science.gov (United States)

    Kodama, Ryosuke

    2013-10-01

    One of the interesting topics on high energy density sciences with high power lasers is creation of extremely high pressures in material. The pressures of more than 0.1 TPa are the energy density corresponding to the chemical bonding energy, resulting in expectation of dramatic changes in the chemical reactions. At pressures of more than TPa, most of material would be melted on the shock Hugoniot curve. However, if the temperature is less than 1eV or lower than a melting point at pressures of more than TPa, novel solid states of matter must be created through a pressured phase transition. One of the interesting materials must be carbon. At pressures of more than TPa, the diamond structure changes to BC and cubic at more than 3TPa. To create such novel states of matter, several kinds of isentropic-like compression techniques are being developed with high power lasers. To explore the ``Tera-Pascal Science,'' now we have a new tool which is an x-ray free electron laser as well as high power lasers. The XFEL will clear the details of the HED states and also efficiently create hot dense matter. We have started a new project on high energy density sciences using an XFEL (SACLA) in Japan, which is a HERMES (High Energy density Revolution of Matter in Extreme States) project.

  8. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    OpenAIRE

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-01

    Background It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). Material/Methods Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin ...

  9. Ac susceptibility of a Bi-2223/Ag tape in a perpendicular field

    International Nuclear Information System (INIS)

    Savvides, N.; Mueller, K.-H.

    1999-01-01

    Full text: We report experimental measurements and theoretical calculations of the real ( X ') and imaginary or loss ( X '') parts of the ac susceptibility as a function of temperature T = 4 - 130 K, frequency ω/2π = 5 Hz - 5 kHz and ac magnetic field amplitude μ 0 H m = 0.02 - 7 mT for of a monofilament silver-sheathed Bi-2223 tape. The susceptibilities consist of a hysteretic component due to ac loss ( Xsc '') in the superconductor core and an eddy current component due to eddy current loss ( Xed '') in the silver sheath. At high temperatures the low frequency limit is used to calculate the hysteretic and eddy current susceptibilities while at low temperatures the susceptibility is found to be due to eddy currents flowing along the edges of the tape. The measured loss at low frequencies (< 50 Hz) and high temperatures is dominated by the hysteresis loss which varies with amplitude but is essentially independent of frequency. At higher frequencies the eddy current loss of the silver sheath becomes dominant and it increases dramatically with frequency at both low and high temperatures

  10. Optimal compliance for amblyopia therapy: occlusion with a translucent tape on the lens.

    Science.gov (United States)

    Beneish, Raquel G; Polomeno, Robert C; Flanders, Michael E; Koenekoop, Robert K

    2009-10-01

    To demonstrate that optimal compliance to amblyopia therapy and a better visual outcome can be achieved by occluding the lens over the preferred eye with a translucent tape. Prospective study of amblyopic children. Eighty-four amblyopic children recruited from 2000 to 2006 at the Montreal Children's Vision Centre. A group of bilateral ametropes (mean age 3.8 years) were treated with glasses and occlusion of the sound eye with a translucent tape on the lens over the preferred eye, or an adhesive patch. The translucent tape reduced vision to hand motion at 0.3 m in the sound eye. Patients were divided into 2 groups depending on the treatment received. Group 1 (n = 36) was occluded with a translucent tape, and group 2 (n = 48) with a conventional adhesive patch, later replaced by the translucent tape. Twenty-five previously reported patients, treated with the conventional adhesive patch only, were used as controls (group 3). The mean amblyopic visual acuity was 20/100-2. Compliance was good in 36 patients (group 1), and was poor or deteriorated in 24/48 patients (group 2). Substituting the adhesive patch with a translucent tape permitted uninterrupted and prolonged occlusion, with a successful visual outcome. The amblyopic eye achieved a significantly better final vision (20/30+2; groups 1+2) than the controls (20/40+1; group 3) (p = 0.04). Sixty-four (76.19%) patients achieved >or=20/30. The translucent tape optimizes compliance and yields better vision by lengthening the duration of occlusion therapy and reducing the number of treatment failures due to noncompliance.

  11. Use of nitrogen cryogun for separating duct tape and recovery of latent fingerprints with a powder suspension method.

    Science.gov (United States)

    Bailey, James A; Crane, Jonathan Stuart

    2011-07-15

    Duct tape is sometimes recovered as physical evidence in crimes. The purpose of this study was to determine the quality of latent prints on the adhesive and non-adhesive surfaces of duct tape samples that were separated using three methods. Three hundred donor fingerprint impressions were deposited on duct tape. Sections of duct tape were affixed to sections of cardboard and a fingerprint placed on the non-adhesive surface of the tape. A second layer of duct tape was prepared and a fingerprint placed on the adhesive side of the tape and then the tape was affixed to the piece of tape on the cardboard. After a 24-h period, the samples were separated using gradual force, liquid nitrogen applied with a cryogun and an adhesive neutralizer to separate the layers of tape. The recovered fingerprints were processed with a fingerprint powder suspension method. The recovered fingerprint images were evaluated and rated as +1, +2, or +3. The liquid nitrogen spray separation method yielded the highest number of +3 prints. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  12. The high density and high βpol disruption mechanism on TFTR

    International Nuclear Information System (INIS)

    Fredrickson, E.D.; Manickam, J.; McGuire, K.M.; Monticello, D.; Nagayama, Y.; Park, W.; Taylor, G.

    1992-01-01

    Studies of disruptions on TFTR have been extended to include high density disruptions as well as the high β pol disruptions. The data strongly suggests that the (m,n)=(1,1) mode plays an important role in both types of disruptions. Further, for the first time, it is unambiguously shown, using a fast electron cyclotron emission (ECE) instrument for the electron temperature profile measurements, that the (m,n)=(1,1) precursor to the high density disruptions has a 'cold bubble' structure. The precursor to the major disruption at high density resembles the 'vacuum bubble' model of disruptions first proposed by Kadomtsev and Pogutse. (author) 2 refs., 2 figs

  13. "Space slitter" for film or tape

    Science.gov (United States)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  14. Mechanical properties of Bi,Pb(2223) single filaments and I sub c (epsilon) behaviour in longitudinally strained tapes

    CERN Document Server

    Passerini, R; Seeber, B; Flükiger, R

    2002-01-01

    The Young's modulus and fracture stress of isolated Bi,Pb(2223) filaments were deduced from three-point bending tests performed at different stages of the tapes preparation. These results were introduced in the model describing the evolution of critical current of tapes submitted to a longitudinal strain in view to predict their irreversible strain limit epsilon sub i sub r sub r. These calculated irreversible strain limits were compared to measured values, taken from a set of tapes made with different filling factors and composite matrices. This experiment shows that the predicted irreversible strain limits correspond to the measured ones. Presenting the I sub c behaviour of highly stressed tapes in a magnetic field, we discuss the evolution of the ratio I sup s sup t sup r sup o sup n sup g sub c sub 0 /I sub c sub 0 versus strain. This value, representative of the fraction of the critical current attributed to strongly connected grains, increases significantly during the crack formation regime at epsilon >...

  15. Influence of bress laminate volume fraction on electromechanical properties of externally laminated coated conductor tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay M.; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Lee, Jae Hun; Lee, Hun Ju; Moon, Seung Hyun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-09-15

    The enhancement of mechanical properties of coated conductor (CC) tapes in practical application are usually achieved by reinforcing through lamination or electroplating metal layers on either sides of the CC tape. Mechanical or electromechanical properties of the CC tapes have been largely affected by the lamination structure under various loading modes such as tension, bending or even cyclic. In this study, the influence of brass laminate volume fraction on electromechanical properties of RCE-DR processed Gadolinium-barium-copper-oxide (GdBCO) CC tapes was investigated. The samples used were composed of single-side and both-side laminate of brass layer to the Cu-stabilized CC tape and their Ic behaviors were compared to those of the Cu-stabilized CC tape without external lamination. The stress/strain dependences of Ic in laminated CC tapes under uniaxial tension were analyzed and the irreversible stress/strain limits were determined. As a result, the increase of brass laminate volume fraction initially increased the irreversible strain limit and became gradual. The corresponding irreversible stress limit, however, showed no difference even though the brass laminate volume fraction increased to 3.4. But the irreversible load limit linearly increased with the brass laminate volume fraction.

  16. A new concept for a compact tape transport system

    International Nuclear Information System (INIS)

    Mlekodaj, R.L.; Zganjar, E.F.; Cole, J.D.

    1981-01-01

    A new concept in tape transport systems for the collection and counting of radioactive samples from an on-line isotope separator has been developed. This new compact design was motivated by space limitations but important additional improvements over previous designs were made in cost, simplicity and vacuum quality. The system is based on a continuous loop of 6.5 mm wide recording tape 116 m long with a conducting coating on one side for beam current monitoring. One small stepping motor is required for operation. (orig.)

  17. Electrode/Dielectric Strip For High-Energy-Density Capacitor

    Science.gov (United States)

    Yen, Shiao-Ping S.

    1994-01-01

    Improved unitary electrode/dielectric strip serves as winding in high-energy-density capacitor in pulsed power supply. Offers combination of qualities essential for high energy density: high permittivity of dielectric layers, thinness, and high resistance to breakdown of dielectric at high electric fields. Capacitors with strip material not impregnated with liquid.

  18. Current evidence does not support the use of Kinesio Taping in clinical practice: a systematic review

    Directory of Open Access Journals (Sweden)

    Patrícia do Carmo Silva Parreira

    2014-03-01

    Full Text Available Questions: Is Kinesio Taping more effective than a sham taping/placebo, no treatment or other interventions in people with musculoskeletal conditions? Is the addition of Kinesio Taping to other interventions more effective than other interventions alone in people with musculoskeletal conditions? Design: Systematic review of randomised trials. Participants: People with musculoskeletal conditions. Intervention: Kinesio Taping was compared with sham taping/placebo, no treatment, exercises, manual therapy and conventional physiotherapy. Outcome measures: Pain intensity, disability, quality of life, return to work, and global impression of recovery. Results: Twelve randomised trials involving 495 participants were included in the review. The effectiveness of the Kinesio Taping was tested in participants with: shoulder pain in two trials; knee pain in three trials; chronic low back pain in two trials; neck pain in three trials; plantar fasciitis in one trial; and multiple musculoskeletal conditions in one trial. The methodological quality of eligible trials was moderate, with a mean of 6.1 points on the 10-point PEDro Scale score. Overall, Kinesio Taping was no better than sham taping/placebo and active comparison groups. In all comparisons where Kinesio Taping was better than an active or a sham control group, the effect sizes were small and probably not clinically significant or the trials were of low quality. Conclusion: This review provides the most updated evidence on the effectiveness of the Kinesio Taping for musculoskeletal conditions. The current evidence does not support the use of this intervention in these clinical populations. PROSPERO registration: CRD42012003436. [Parreira PdCS, Costa LdCM, Hespanhol Junior LC, Lopes AD, Costa LOP (2014 Current evidence does not support the use of Kinesio Taping in clinical practice: a systematic review. Journal of Physiotherapy 60: 31–39

  19. Alternating current loss characteristics in (bismuth,lead)SCCO and yttrium barium copper oxide superconducting tapes

    Science.gov (United States)

    Nguyen, Doan Ngoc

    Alternating current (AC) loss and current carrying capacity are two of the most crucial considerations in large-scale power applications of high temperature superconducting (HTS) conductors. AC losses result in an increased thermal load for cooling machines, and thus increased operating costs. Furthermore, AC losses can stimulate quenching phenomena or at least decrease the stability margin for superconducting devices. Thus, understanding AC losses is essential for the development of HTS AC applications. The main focus of this dissertation is to make reliable total AC loss measurements and interpret the experimental results in a theoretical framework. With a specially designed magnet, advanced total AC loss measurement system in liquid nitrogen (77 K) has been successfully built. Both calorimetric and electromagnetic methods were employed to confirm the validity of the measured results and to have a more thorough understanding of AC loss in HTS conductors. The measurement is capable of measuring total AC loss in HTS tapes over a wide range of frequency and amplitude of transport current and magnetic field. An accurate phase control technique allows measurement of total AC loss with any phase difference between the transport current and magnetic field by calorimetric method. In addition, a novel total AC loss measurement system with variable temperatures from 30 K to 100 K was successfully built and tested. Understanding the dependence of AC losses on temperature will enable optimization of the operating temperature and design of HTS devices. As a part of the dissertation, numerical calculations using Brandt's model were developed to study electrodynamics and total AC loss in HTS conductors. In the calculations, the superconducting electrical behavior is assumed to follow a power-law model. In general, the practical properties of conductors, including field-dependence of critical current density Jc, n-value and non-uniform distribution of Jc, can be accounted for in

  20. Laser fusion and high energy density science

    International Nuclear Information System (INIS)

    Kodama, Ryosuke

    2005-01-01

    High-power laser technology is now opening a variety of new fields of science and technology using laser-produced plasmas. The laser plasma is now recognized as one of the important tools for the investigation and application of matter under extreme conditions, which is called high energy density science. This chapter shows a variety of applications of laser-produced plasmas as high energy density science. One of the more attractive industrial and science applications is the generation of intense pulse-radiation sources, such as the generation of electro-magnetic waves in the ranges of EUV (Extreme Ultra Violet) to gamma rays and laser acceleration of charged particles. The laser plasma is used as an energy converter in this regime. The fundamental science applications of high energy density physics are shown by introducing laboratory astrophysics, the equation of state of high pressure matter, including warm dense matter and nuclear science. Other applications are also presented, such as femto-second laser propulsion and light guiding. Finally, a new systematization is proposed to explore the possibility of the high energy density plasma application, which is called high energy plasma photonics''. This is also exploration of the boundary regions between laser technology and beam optics based on plasma physics. (author)

  1. Effect of fibular repositioning taping in adult basketball players with chronic ankle instability: a randomized, placebo-controlled, crossover trial.

    Science.gov (United States)

    Alves, Yanina; Ribeiro, Fernando; Silva, Anabela G

    2017-07-05

    Chronic ankle instability presents a high incidence and prevalence in basketbal players. It's important to develop strategies to reduce the functional and mechanical limitations resulting from this condition. To compare the effect of Mulligan ́s fibular repositioning taping with a placebo taping immediatly after application and after a running test (Yo-Yo IRT). 16 adult basketball players (10 male, 6 female) with chronic ankle instability and mean age 21.50 ± 2.76 years old. Assessment of static postural control (15 seconds of unipedal stance test with eyes closed in a force platform), functional performance (figure 8 hop test and lateral hop test) and neuromuscular control (peroneus longus latency time in sudden inversion) in two conditions: Mulligan and Placebo. No significant effect was found for the intervantion factor in both hop tests (p>0.170), but there was a significant effect for the time factor (p<0.03). For the peroneus longus latency time, there was a significant interaction between factors (p=0.028) and also for time (p=0.042). No significant effect was found for any of the static postural control variables (area, speed and total displacement) (p≥0.10). There was no differences between Mulligan's fibular repositioning taping and Placebo taping in postural control and functional performance in basketball players with chronic ankle instability. However, Mulligan's taping appears to reduce peroneus longus latency time after a running when compared with a placebo taping.

  2. TiO2/water Nanofluid Heat Transfer in Heat Exchanger Equipped with Double Twisted-Tape Inserts

    Science.gov (United States)

    Eiamsa-ard, S.; Ketrain, R.; Chuwattanakul, V.

    2018-05-01

    Nowadays, heat transfer enhancement plays an important role in improving efficiency of heat transfer and thermal systems for numerous areas such as heat recovery processes, chemical reactors, air-conditioning/refrigeration system, food engineering, solar air/water heater, cooling of high power electronics etc. The present work presents the experimental results of the heat transfer enhancement of TiO2/water nanofluid in a heat exchanger tube fitted with double twisted tapes. The study covered twist ratios of twisted tapes (y/w) of 1.5, 2.0, and 2.5) while the concentration of the nanofluid was kept constant at 0.05% by volume. Observations show that heat transfer, friction loss and thermal performance increase as twist ratio (y/w) decreases. The use of the nanofluid in the tube equipped with the double twisted-tapes with the smallest twist ratio (y/w = 1.5) results in the increases of heat transfer rates and friction factor up to 224.8% and 8.98 times, respectively as compared to those of water. In addition, the experimental results performed that double twisted tapes induced dual swirling-flows which played an important role in improving fluid mixing and heat transfer enhancement. It is also observed that the TiO2/water nanofluid was responsible for low pressure loss behaviors.

  3. Experiment of enhancing critical current and reducing ac loss in pancake coil comprised of Ni-coated Bi-2223/Ag tape

    International Nuclear Information System (INIS)

    Alamgir, A.K.M.; Gu, C.; Han, Z.

    2006-01-01

    An approach of realizing high performance HTS coil comprised of ferromagnetic material-coated BSCCO tape is proposed. The concept of influencing critical current and ac loss is based on the magnetic shielding effect resulting in redirection of self-field flux-lines. In the previous article, ac performance of Ni-coated tape was demonstrated where the Ni-coating was introduced at the edge-regime of the finished tape in order to redirect the perpendicular component of self-field lines. In order to investigate the shielding effect on ac performance in HTS coil, a two-turn pancake coil comprised of Ni-coated Bi-2223/Ag tape is demonstrated in the present article. About 6.4% of critical current was enhanced and 30% of transport current ac loss was reduced by means of 40 μm thick and 0.3 mm long (from the edge toward center of the tape) Ni-coating. This result suggests that additional ferromagnetic loss could be compensated well by the shielding effect of the partial Ni-coating. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the volume and geometry of ferromagnetic coating introduced. Therefore, it is very important to control the parameter of ferromagnetic coating of the tape in order to balance the critical current and ac loss for optimum coil performance

  4. Experiment of enhancing critical current and reducing ac loss in pancake coil comprised of Ni-coated Bi-2223/Ag tape

    Energy Technology Data Exchange (ETDEWEB)

    Alamgir, A.K.M. [Department of Physics, Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China)]. E-mail: alam643@hotmail.com; Gu, C. [Department of Physics, Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China); Han, Z. [Department of Physics, Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China)

    2006-07-01

    An approach of realizing high performance HTS coil comprised of ferromagnetic material-coated BSCCO tape is proposed. The concept of influencing critical current and ac loss is based on the magnetic shielding effect resulting in redirection of self-field flux-lines. In the previous article, ac performance of Ni-coated tape was demonstrated where the Ni-coating was introduced at the edge-regime of the finished tape in order to redirect the perpendicular component of self-field lines. In order to investigate the shielding effect on ac performance in HTS coil, a two-turn pancake coil comprised of Ni-coated Bi-2223/Ag tape is demonstrated in the present article. About 6.4% of critical current was enhanced and 30% of transport current ac loss was reduced by means of 40 {mu}m thick and 0.3 mm long (from the edge toward center of the tape) Ni-coating. This result suggests that additional ferromagnetic loss could be compensated well by the shielding effect of the partial Ni-coating. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the volume and geometry of ferromagnetic coating introduced. Therefore, it is very important to control the parameter of ferromagnetic coating of the tape in order to balance the critical current and ac loss for optimum coil performance.

  5. Operation and control of high density tokamak reactors

    International Nuclear Information System (INIS)

    Attenberger, S.E.; McAlees, D.G.

    1976-01-01

    The incentive for high density operation of a tokamak reactor was discussed. It is found that high density permits ignition in a relatively small, moderately elongated plasma with a moderate magnetic field strength. Under these conditions, neutron wall loadings approximately 4 MW/m 2 must be tolerated. The sensitivity analysis with respect to impurity effects shows that impurity control will most likely be necessary to achieve the desired plasma conditions. The charge exchange sputtered impurities are found to have an important effect so that maintaining a low neutral density in the plasma is critical. If it is assumed that neutral beams will be used to heat the plasma to ignition, high energy injection is required (approximately 250 keV) when heating is accompished at full density. A scenario is outlined where the ignition temperature is established at low density and then the fueling rate is increased to attain ignition. This approach may permit beams with energies being developed for use in TFTR to be successfully used to heat a high density device of the type described here to ignition

  6. High density high-TC ceramic superconductors by hot pressing

    International Nuclear Information System (INIS)

    Mak, S.; Chaklader, A.C.D.

    1989-01-01

    High density and high T C superconductor specimens, YBa 2 Cu 3 O x , have been produced by hot-pressing. The factors studied are the effect of hot pressing on the density, the oxygen stoichiometry, the crystal structure, and the critical temperature. Hot pressing followed by heat treatment increased the density of the specimen to 93%. The hot pressing itself did not significantly affect the oxygen content in the specimen, and although the crystal structure appeared to be orthorhombic, the specimens were not superconducting above liquid nitrogen temperature. The superconductivity was restored after head treatment in oxygen. The highest critical temperature (T C ) of the hot pressed pellets was 82K, which was slightly lower than the T C that could be obtained with the cold pressed/sintered pellets. (6 refs., 5 figs., tab.)

  7. Comparison of Broselow tape measurements versus mother estimations of pediatric weights

    Directory of Open Access Journals (Sweden)

    Sherafat Akaberian

    2013-06-01

    Full Text Available Background Pediatric resuscitation is challenging for therapeutic group. The most physicians have limited experience in dealing with this situation. Appropriate dosing of the drugs depends on the body weight of the children that it is usually not feasible. There is need for a fast, convenient and reliable method for body weight estimation in children. The aim of this study was to assess the accuracy of Broselow tape in children of Bushehr city. Material and Methods: This cross-sectional study was conducted in the emergency department of Aliasghar hospital. Children were between 1 month and 14 years. Children with chronic disease, 334, ill children were excluded from study. Estimated weight measured based on Broselow tape and actual weight measured by digital scale, then estimated and actual weight were compared. The results were analyzed by SPSS Software Ver 18 and T-Test, Chi-Square Test. Results: findings showed that 43.2% of total subjects were female Mean of age were 43 months. 72.5% of tape body weights were within  10% error of actual body weights. 78.9% of tape body weight was within  15% error of actual body weights. There was no significant difference between boys and girls. Conclusion: Broslow tape was easy, fast and exact for body weight estimation in emergency situation .it is more exact of body weight estimation by parents or therapeutic group so it helps therapeutic group in emergency department for accounting of medication dosage and equipment sizes.

  8. Feedback controlled, reactor relevant, high-density, high-confinement scenarios at ASDEX Upgrade

    Science.gov (United States)

    Lang, P. T.; Blanken, T. C.; Dunne, M.; McDermott, R. M.; Wolfrum, E.; Bobkov, V.; Felici, F.; Fischer, R.; Janky, F.; Kallenbach, A.; Kardaun, O.; Kudlacek, O.; Mertens, V.; Mlynek, A.; Ploeckl, B.; Stober, J. K.; Treutterer, W.; Zohm, H.; ASDEX Upgrade Team

    2018-03-01

    One main programme topic at the ASDEX Upgrade all-metal-wall tokamak is development of a high-density regime with central densities at reactor grade level while retaining high-confinement properties. This required development of appropriate control techniques capable of coping with the pellet tool, a powerful means of fuelling but one which presented challenges to the control system for handling of related perturbations. Real-time density profile control was demonstrated, raising the core density well above the Greenwald density while retaining the edge density in order to avoid confinement losses. Recently, a new model-based approach was implemented that allows direct control of the central density. Investigations focussed first on the N-seeding scenario owing to its proven potential to yield confinement enhancements. Combining pellets and N seeding was found to improve the divertor buffering further and enhance the operational range accessible. For core densities up to about the Greenwald density, a clear improvement with respect to the non-seeding reference was achieved; however, at higher densities this benefit is reduced. This behaviour is attributed to recurrence of an outward shift of the edge density profile, resulting in a reduced peeling-ballooning stability. This is similar to the shift seen during strong gas puffing, which is required to prevent impurity influx in ASDEX Upgrade. First tests indicate that highly-shaped plasma configurations like the ITER base-line scenario, respond very well to pellet injection, showing efficient fuelling with no measurable impact on the edge density profile.

  9. Effect of athletic taping and kinesiotaping® on measurements of functional performance in basketball players with chronic inversion ankle sprains.

    Science.gov (United States)

    Bicici, Seda; Karatas, Nihan; Baltaci, Gul

    2012-04-01

    Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Crossover Study Design Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping

  10. The Variation of Interface Formation with Slurry Viscosity Change in Side-By-Side Tape Casting

    DEFF Research Database (Denmark)

    Bulatova, Regina; Jabbari, Masoud; Andersen, Kjeld Bøhm

    Homogenous and flexible adjacently graded tapes were produced by casting the organic-based slurries simultaneously. To develop side-by-side tape casing (SBSTC), the material optimization, modernization of the doctor blade design, and parameters control of such processes as casting, drying, de......-bindering and sintering were studied. Solvent and binder concentrations were varied in order to optimize co-casting flow, as well as the drying and sintering shrinkage. Tapes were evaluated in terms of rheological behavior of the slurries, the green and sintered tape microstructure, the quality of the interface area...

  11. High-density-plasma diagnostics in magnetic-confinement fusion

    International Nuclear Information System (INIS)

    Jahoda, F.C.

    1982-01-01

    The lectures will begin by defining high density in the context of magnetic confinement fusion research and listing some alternative reactor concepts, ranging from n/sub e/ approx. 2 x 10 14 cm -3 to several orders of magnitude greater, that offer potential advantages over the main-line, n/sub e/ approx. 1 x 10 14 cm -3 , Tokamak reactor designs. The high density scalings of several major diagnostic techniques, some favorable and some disadvantageous, will be discussed. Special emphasis will be given to interferometric methods, both electronic and photographic, for which integral n/sub e/dl measurements and associated techniques are accessible with low wavelength lasers. Reactor relevant experience from higher density, smaller dimension devices exists. High density implies high β, which implies economies of scale. The specialized features of high β diagnostics will be discussed

  12. Ankle taping can reduce external ankle joint moments during drop landings on a tilted surface.

    Science.gov (United States)

    Sato, Nahoko; Nunome, Hiroyuki; Hopper, Luke S; Ikegami, Yasuo

    2017-09-20

    Ankle taping is commonly used to prevent ankle sprains. However, kinematic assessments investigating the biomechanical effects of ankle taping have provided inconclusive results. This study aimed to determine the effect of ankle taping on the external ankle joint moments during a drop landing on a tilted surface at 25°. Twenty-five participants performed landings on a tilted force platform that caused ankle inversion with and without ankle taping. Landing kinematics were captured using a motion capture system. External ankle inversion moment, the angular impulse due to the medio-lateral and vertical components of ground reaction force (GRF) and their moment arm lengths about the ankle joint were analysed. The foot plantar inclination relative to the ground was assessed. In the taping condition, the foot plantar inclination and ankle inversion angular impulse were reduced significantly compared to that of the control. The only component of the external inversion moment to change significantly in the taped condition was a shortened medio-lateral GRF moment arm length. It can be assumed that the ankle taping altered the foot plantar inclination relative to the ground, thereby shortening the moment arm of medio-lateral GRF that resulted in the reduced ankle inversion angular impulse.

  13. The effect of kinesio taping in forward bending of the lumbar spine.

    Science.gov (United States)

    Lemos, Thiago Vilela; Albino, Anna Carolina Gonçalves; Matheus, Joao Paulo C; Barbosa, Aurélio de Melo

    2014-09-01

    [Purpose] The aim of this study was to evaluate the influence of a lumbar fascia Kinesio Taping(®) technique forward bending range of motion. [Subjects and Methods] This was a longitudinal study with a randomized clinical trial composed of 39 subjects divided into three groups (control, Kinesio Without Tension-KWT, and Kinesio Fascia Correction-KFC). The subjects were assessed by Schober and fingertip-to-floor tests and left the tape in place for 48 hours before being reassessed 24 hours, 48 hours and 30 days after its removal. [Results] In all three experimental groups no significant differences were observed with the Schober test, but it was possible to observe an increase in lumbar flexion after 30 days. With the fingertip-to-floor distance assessment, the KFC and KWT groups showed significantly improved flexibility 24 hours and 48 hours after tape removal. [Conclusion] The Kinesio Taping(®) influenced fascia mobility, allowing for slight improvement of lumbar flexibility.

  14. Computer tape library for collective dose assessments in the European Community

    International Nuclear Information System (INIS)

    Jones, J.A.; Kelly, G.N.

    1981-01-01

    A computer tape library has been established which can readily be applied to enable calculations to be made of the collective dose to the population of the European Community from radioactive effluent discharges within the EC. The background to the development of the tape library and details of its contents, method of application and availability are summarised in this note. (author)

  15. Enhanced and uniform in-field performance in long (Gd, Y)-Ba-Cu-O tapes with zirconium doping fabricated by metal-organic chemical vapor deposition

    International Nuclear Information System (INIS)

    Selvamanickam, V; Guevara, A; Zhang, Y; Kesgin, I; Xie, Y; Carota, G; Chen, Y; Dackow, J; Zhang, Y; Zuev, Y; Cantoni, C; Goyal, A; Coulter, J; Civale, L

    2010-01-01

    The influence of Zr doping in (Gd, Y)-Ba-Cu-O ((Gd, Y)BCO) tapes made by metal-organic chemical vapor deposition has been studied with a specific objective of uniform and reproducible enhancement in in-field critical current (I c ) over long lengths. 50 m long tapes with 7.5 and 10 at.% Zr doping in 1 μm thick (Gd, Y)BCO films have been found to exhibit a sharply enhanced peak in I c in the orientation of field parallel to the c-axis and retain 28% of their self-field I c value at 77 K and 1 T. BaZrO 3 (BZO) nanocolumn density in the cross-sectional microstructure was found to increase with increasing Zr addition. The end segments of the 50 m long tapes were found to display nearly identical angular dependence of critical current at 77 K and 1 T, indicative of the uniformity in in-field performance over this length. A 610 m long tape was fabricated with 10% Zr doping and a 130 m segment showed a 3.2% uniformity in critical current measured every meter in the orientation of B || c-axis. A retention factor of 36% of the zero-field I c value measured at 0.52 T over the 130 m is consistent with that obtained in short samples.

  16. Enhanced and uniform in-field performance in long (Gd, Y)-Ba-Cu-O tapes with zirconium doping fabricated by metal-organic chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V; Guevara, A; Zhang, Y; Kesgin, I [Texas Center for Superconductivity and Department of Mechanical Engineering, University of Houston, Houston, TX 77059 (United States); Xie, Y; Carota, G; Chen, Y; Dackow, J [SuperPower Incorporated, 450 Duane Avenue Schenectady, NY 12304 (United States); Zhang, Y; Zuev, Y; Cantoni, C; Goyal, A [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Coulter, J; Civale, L [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2010-01-15

    The influence of Zr doping in (Gd, Y)-Ba-Cu-O ((Gd, Y)BCO) tapes made by metal-organic chemical vapor deposition has been studied with a specific objective of uniform and reproducible enhancement in in-field critical current (I{sub c}) over long lengths. 50 m long tapes with 7.5 and 10 at.% Zr doping in 1 {mu}m thick (Gd, Y)BCO films have been found to exhibit a sharply enhanced peak in I{sub c} in the orientation of field parallel to the c-axis and retain 28% of their self-field I{sub c} value at 77 K and 1 T. BaZrO{sub 3} (BZO) nanocolumn density in the cross-sectional microstructure was found to increase with increasing Zr addition. The end segments of the 50 m long tapes were found to display nearly identical angular dependence of critical current at 77 K and 1 T, indicative of the uniformity in in-field performance over this length. A 610 m long tape was fabricated with 10% Zr doping and a 130 m segment showed a 3.2% uniformity in critical current measured every meter in the orientation of B || c-axis. A retention factor of 36% of the zero-field I{sub c} value measured at 0.52 T over the 130 m is consistent with that obtained in short samples.

  17. Enhanced and Uniform in-Field Performance in Long (Gd,Y)-Ba-Cu-O Tapes with Zirconium Doping Fabricated by Metal Organic Chemical Vapor Deposition

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V. [SuperPower Incorporated, Schenectady, New York; Guevara, A. [University of Houston, Houston; Zhang, Y. [University of Houston, Houston; Kesign, I. [University of Houston, Houston; Xie, Y. Y. [SuperPower Incorporated, Schenectady, New York; Carota, G. [SuperPower Incorporated, Schenectady, New York; Chen, Y. [SuperPower Incorporated, Schenectady, New York; Dackow, J. [SuperPower Incorporated, Schenectady, New York; Zhang, Yifei [ORNL; Zuev, Yuri L [ORNL; Cantoni, Claudia [ORNL; Goyal, Amit [ORNL; Coulter, J. [Los Alamos National Laboratory (LANL); Civale, L. [Los Alamos National Laboratory (LANL)

    2010-01-01

    The influence of Zr doping in (Gd, Y)-Ba-Cu-O ((Gd, Y)BCO) tapes made by metal-organic chemical vapor deposition has been studied with a specific objective of uniform and reproducible enhancement in in-field critical current (I{sub c}) over long lengths. 50 m long tapes with 7.5 and 10 at.% Zr doping in 1 {mu}m thick (Gd, Y)BCO films have been found to exhibit a sharply enhanced peak in I{sub c} in the orientation of field parallel to the c-axis and retain 28% of their self-field I{sub c} value at 77 K and 1 T. BaZrO{sub 3} (BZO) nanocolumn density in the cross-sectional microstructure was found to increase with increasing Zr addition. The end segments of the 50 m long tapes were found to display nearly identical angular dependence of critical current at 77 K and 1 T, indicative of the uniformity in in-field performance over this length. A 610 m long tape was fabricated with 10% Zr doping and a 130 m segment showed a 3.2% uniformity in critical current measured every meter in the orientation of {beta} {parallel} c-axis. A retention factor of 36% of the zero-field I{sub c} value measured at 0.52 T over the 130 m is consistent with that obtained in short samples.

  18. Superconducting properties of YBa2Cu3O7−δ films deposited on commercial tape substrates, decorated with Pd or Ta nano-islands

    International Nuclear Information System (INIS)

    Polat, Ö; Thompson, J R; Leonard, K J; Wee, S H; Christen, D K; Ertuğrul, M; Sinclair, J W; Zuev, Y L; Paranthaman, M P; Aytuğ, T; Xiong, X; Selvamanickam, V

    2012-01-01

    To obtain an engineered surface for deposition of high-T c superconductors, nanoscale modulations of the surface of the underlying LaMnO 3 (LMO) cap layer is a potential source for generating microstructural defects in YBa 2 Cu 3 O 7−δ (YBCO) films. These defects may improve the flux pinning and consequently increase the critical current density, J c . To provide such nanoscale modulation via a practical and scalable process, palladium (Pd) or tantalum (Ta) nano-islands were deposited using dc-magnetron sputtering on the surface of the cap layer of commercial metal tape templates for second-generation wires. The size and density of these nano-islands can be controlled by changing sputtering conditions such as the power and deposition time. Compared to the reference sample grown on an untreated LMO cap layer, the YBCO films grown on the LMO cap layers with Pd or Ta nano-islands exhibited improved in-field J c performance. Atomic force microscopy and transmission electron microscopy were used to assess the evolving size and density of the nano-islands. (paper)

  19. Probing topological relations between high-density and low-density regions of 2MASS with hexagon cells

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Yongfeng [American Physical Society, San Diego, CA (United States); Xiao, Weike, E-mail: yongfeng.wu@maine.edu [Department of Astronautics Engineering, Harbin Institute of Technology, P.O. Box 345, Heilongjiang Province 150001 (China)

    2014-02-01

    We introduced a new two-dimensional (2D) hexagon technique for probing the topological structure of the universe in which we mapped regions of the sky with high and low galaxy densities onto a 2D lattice of hexagonal unit cells. We defined filled cells as corresponding to high-density regions and empty cells as corresponding to low-density regions. The numbers of filled cells and empty cells were kept the same by controlling the size of the cells. By analyzing the six sides of each hexagon, we could obtain and compare the statistical topological properties of high-density and low-density regions of the universe in order to have a better understanding of the evolution of the universe. We applied this hexagonal method to Two Micron All Sky Survey data and discovered significant topological differences between the high-density and low-density regions. Both regions had significant (>5σ) topological shifts from both the binomial distribution and the random distribution.

  20. 'Twisted tape sign': Its significance in recurrent sigmoid volvulus

    International Nuclear Information System (INIS)

    Gopal, K.; Lim, Y.; Banerjee, B.

    2005-01-01

    Aim: Sigmoid volvulus is a common cause of intestinal obstruction in the elderly. Mild attacks of sigmoid volvulus may be more difficult to diagnose due to the lack of severity of symptoms which may resolve spontaneously only to recur after an interval. This study was a review of patients to assess the incidence of the 'twisted tape sign' and to evaluate the significance of its presence in cases of recurrent sigmoid volvulus. Methods and materials: A retrospective study over eight years revealed six cases of surgically confirmed recurrent sigmoid volvulus. Case records and barium enemas of all patients were reviewed. Results: Six patients were identified, including four men and two women, with a median age of 56 years. Diagnostic difficulties were encountered in four (67%) patients with a delay ranging between 10 and 37 months with a mean 17.3 months. Twisted tape sign was confirmed on all barium examinations retrospectively. Conclusion: Recognition of twisted tape sign on barium enema examination along with an appropriate clinical history would suggest a diagnosis of recurrent sigmoid volvulus

  1. Sun StorageTek T9940 Tape Drive

    CERN Multimedia

    2002-01-01

    Technology allowed reuse of the same data cartridge at higher capacity with later model of the tape drive hence offering significant savings of the media cost. It has been use by the CERN from 2002 to 2008.

  2. Symmetric tape round REBCO wire with J e (4.2 K, 15 T) beyond 450 A mm-2 at 15 mm bend radius: a viable candidate for future compact accelerator magnet applications

    Science.gov (United States)

    Kar, Soumen; Luo, Wenbo; Ben Yahia, Anis; Li, Xiaofen; Majkic, Goran; Selvamanickam, Venkat

    2018-04-01

    Round REBCO (RE = rare earth) wires of 1.6-1.85 mm diameter have been fabricated using ultrathin REBCO tapes where the superconductor film is positioned near the geometric center. Such symmetric tape round (STAR) wires exhibit excellent tolerance to bend strain with a critical current retention of more than 97% when bent to a radius of 15 mm. A 1.6 mm diameter REBCO STAR wire made with six 2.5 mm wide symmetric tapes reached an engineering current density (J e) of 454 A mm-2 at 4.2 K in a background field of 15 T at a bend radius of 15 mm. Such superior performance at a small bend radius can enable fabrication of future accelerator magnets, operating at magnetic fields above 20 T.

  3. Towards high-density matter with relativistic heavy-ion collisions

    International Nuclear Information System (INIS)

    Nagamiya, Shoji.

    1990-04-01

    Recent progress in nucleus-nucleus collisions at BNL and CERN suggests a hint that the formation of high-density nuclear matter could be possible with relativistic heavy-ion beams. What is the maximum density that can be achieved by heavy-ion collisions? Are there data which show evidence or hints on the formation of high density matter? Why is the research of high-density interesting? How about the future possibilities on this subject? These points are discussed. (author)

  4. New aspects of high energy density plasma

    International Nuclear Information System (INIS)

    Hotta, Eiki

    2005-10-01

    The papers presented at the symposium on 'New aspects of high energy density plasma' held at National Institute for Fusion Science are collected in this proceedings. The papers reflect the present status and recent progress in the experiments and theoretical works on high energy density plasma produced by pulsed power technology. The 13 of the presented papers are indexed individually. (J.P.N.)

  5. Automatic storage of single gamma spectra on magnetic tape. Programs Longo, Dire

    International Nuclear Information System (INIS)

    Los Arcos Merino, J.M.

    1978-01-01

    The program Longo provides the block size and the black number in a binary file on magnetic tape. It has been applied to analyse the structure of the nine-track magnetic tapes storing single or coincidence gamma spectra files, recorded in octet form by a Multi-8 minicomputer in the Nuclear Spectrometry Laboratory of J.E.N. Then the program Dire has been written to transform the single gamma spectra into a new Fastrand disk file, storing the information in 36 bit words. A copy of this file is obtained on magnetic tape and the single gamma spectra are then availables by standard Fortran V reading sentences. (author)

  6. Automatic storing of single gamma spectra on magnetic tape. Programs LONGO, DIRE

    International Nuclear Information System (INIS)

    Los Arcos Merino, J. M.

    1978-01-01

    The program LONGO provides the block size and the block number in a binary file on magnetic tape. It has been applied to analyse the structure of the nine-track magnetic tapes storing single or coincidence gamma spectra files, recorded in octet form by a MULTI-8 minicomputer in the Nuclear Spectrometry Laboratory of J.E.N. Then the program DIRE has been written to transform the single gamma spectra into a new FASTRAND disk file, storing the information in-36 bit words. A copy of this file is obtained on magnetic tape and the single gamma spectra are then available by standard FORTRAN V reading sentences. (Author) 3 refs

  7. A 5.9 tesla conduction-cooled coil composed of a stack of four single pancakes wound with YBCO wide tapes

    Science.gov (United States)

    Iwai, Sadanori; Miyazaki, Hiroshi; Tosaka, Taizo; Tasaki, Kenji; Urata, Masami; Ioka, Shigeru; Ishii, Yusuke

    2013-11-01

    We have been developing a conduction-cooled coil wound with YBCO-coated conductors for HTS applications. Previously, we have fabricated a coil composed of a stack of 12 single pancakes wound with 4 mm-wide YBCO tapes. This coil had a central magnetic field as high as 5.1 T at 10 K under conduction-cooled conditions. In the present study, we fabricated and tested a coil composed of a stack of four single pancakes wound with 12 mm-wide YBCO tapes. The total size of the coil and the Jc value of the tapes were almost the same as those of the former coil. At 77 K, the voltage-current characteristics showed a high n-value of 24, confirming that the coil had no degradation. Furthermore, in a conduction-cooled configuration at 20 K to 60 K, the coil showed a high n-value of over 20. At 20 K, the central magnetic field reached 5.9 T at 903 A, which is 1.3-times higher than that of the former coil.

  8. Performance Assessment in a Heat Exchanger Tube with Opposite/Parallel Wing Twisted Tapes

    Directory of Open Access Journals (Sweden)

    S. Eiamsa-ard

    2015-02-01

    Full Text Available The thermohydraulic performance in a tube containing a modified twisted tape with alternate-axes and wing arrangements is reported. This work aims to investigate the effects of wing arrangements (opposite (O and parallel (P wings at different wing shapes (triangle (Tri, rectangular (Rec, and trapezoidal (Tra wings and on the thermohydraulic performance characteristics. The obtained results show that wing twisted tapes with all wing shape arrangements (O-Tri/O-Rec/O-Tra/P-Tri/P-Rec/P-Tra give superior thermohydraulic performance and heat transfer rate to the typical twisted tape. In addition, the tapes with opposite wing arrangement of O-Tra, O-Rec, and O-Tri give superior thermohydraulic performances to those with parallel wing arrangement of P-Tra, P-Rec, and P-Tri around 2.7%, 3.5%, and 3.2%, respectively.

  9. Numerical Analysis of Heat transfer Enhancement in a double pipe heat exchanger with a holed twisted tape

    Directory of Open Access Journals (Sweden)

    Kumar Akarsh

    2018-01-01

    Full Text Available In the present study numerical analysis of enhancement in heat transfer characteristics in a double pipe heat exchanger is studied using a holed twisted tape.The twisted tape with a constant twist ratio is inserted in a double pipe heat exchanger. Holes of diameter 1mm, 3 mm and 5 mm were drilled at regular pitch throughout the length of the tape. Numerical modeling of a double pipe heat exchanger with the holed twisted tape was constructed considering hot fluid flowing in the inner pipe and cold fluid through the annulus.Simulation was done for varied mass flow rates of hot fluid in the turbulent condition keeping the mass flow rate of cold fluid being constant. Thermal properties like Outlet temperatures, Nusselt number, overall heat transfer coefficient, heat transfer rate and pressure drop were determined for all the cases. Results indicated that normaltwisted tape without holes performed better than the bare tube. In the tested range of mass flow rates the average Nusselt number and heat transfer rate were increased by 85% and 34% respectively. Performance of Twisted tape with holes was slightly reduced than the normal twisted tape and it deteriorated further for higher values hole diameter. Pressure drop was found to be higher for the holed twisted tape than the normal tape.

  10. High current density ion source

    International Nuclear Information System (INIS)

    King, H.J.

    1977-01-01

    A high-current-density ion source with high total current is achieved by individually directing the beamlets from an electron bombardment ion source through screen and accelerator electrodes. The openings in these screen and accelerator electrodes are oriented and positioned to direct the individual beamlets substantially toward a focus point. 3 figures, 1 table

  11. Ceramic tape casting: A review of current methods and trends with emphasis on rheological behaviour and flow analysis

    International Nuclear Information System (INIS)

    Jabbari, M.; Bulatova, R.; Tok, A.I.Y.; Bahl, C.R.H.; Mitsoulis, E.; Hattel, J.H.

    2016-01-01

    Highlights: • Brief review of the tape casting process for ceramics. • Role of fluid flow analysis in tape casting of ceramics. • Rheological classification of common fluids in tape casting. • Review of commonly used rheological behaviour for ceramics in tape casting. - Abstract: Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Today, tape casting is the basic fabrication process that provides multilayered capacitors and multilayered ceramic packages. In tape casting the rheological behaviour of the slurry as well as the material flow during casting are of utmost importance since these phenomena to a large extent determine the final properties and hence the quality of the cast product. During the last decades this has led to an increasing number of works in literature within fluid flow analysis of tape casting. In the present paper a review of the development of the tape casting process with particular focus on the rheological classifications as well as modelling the material flow is hence presented and in this context the current status is examined and future potential discussed.

  12. Ceramic tape casting: A review of current methods and trends with emphasis on rheological behaviour and flow analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jabbari, M., E-mail: mjab@mek.dtu.dk [Process Modelling Group, Department of Mechanical Engineering, Technical University of Denmark, Nils Koppels Allé, 2800 Kgs. Lyngby (Denmark); Bulatova, R. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, Building 779, Roskilde (Denmark); Tok, A.I.Y. [School of Materials Science & Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Bahl, C.R.H. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, Building 779, Roskilde (Denmark); Mitsoulis, E. [School of Mining Engineering and Metallurgy, National Technical University of Athens, Zografou, 15780 Athens (Greece); Hattel, J.H. [Process Modelling Group, Department of Mechanical Engineering, Technical University of Denmark, Nils Koppels Allé, 2800 Kgs. Lyngby (Denmark)

    2016-10-15

    Highlights: • Brief review of the tape casting process for ceramics. • Role of fluid flow analysis in tape casting of ceramics. • Rheological classification of common fluids in tape casting. • Review of commonly used rheological behaviour for ceramics in tape casting. - Abstract: Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Today, tape casting is the basic fabrication process that provides multilayered capacitors and multilayered ceramic packages. In tape casting the rheological behaviour of the slurry as well as the material flow during casting are of utmost importance since these phenomena to a large extent determine the final properties and hence the quality of the cast product. During the last decades this has led to an increasing number of works in literature within fluid flow analysis of tape casting. In the present paper a review of the development of the tape casting process with particular focus on the rheological classifications as well as modelling the material flow is hence presented and in this context the current status is examined and future potential discussed.

  13. Robotic tape library system level testing at NSA: Present and planned

    Science.gov (United States)

    Shields, Michael F.

    1994-01-01

    In the present of declining Defense budgets, increased pressure has been placed on the DOD to utilize Commercial Off the Shelf (COTS) solutions to incrementally solve a wide variety of our computer processing requirements. With the rapid growth in processing power, significant expansion of high performance networking, and the increased complexity of applications data sets, the requirement for high performance, large capacity, reliable and secure, and most of all affordable robotic tape storage libraries has greatly increased. Additionally, the migration to a heterogeneous, distributed computing environment has further complicated the problem. With today's open system compute servers approaching yesterday's supercomputer capabilities, the need for affordable, reliable secure Mass Storage Systems (MSS) has taken on an ever increasing importance to our processing center's ability to satisfy operational mission requirements. To that end, NSA has established an in-house capability to acquire, test, and evaluate COTS products. Its goal is to qualify a set of COTS MSS libraries, thereby achieving a modicum of standardization for robotic tape libraries which can satisfy our low, medium, and high performance file and volume serving requirements. In addition, NSA has established relations with other Government Agencies to complete this in-house effort and to maximize our research, testing, and evaluation work. While the preponderance of the effort is focused at the high end of the storage ladder, considerable effort will be extended this year and next at the server class or mid range storage systems.

  14. Plasma Photonic Devices for High Energy Density Science

    International Nuclear Information System (INIS)

    Kodama, R.

    2005-01-01

    High power laser technologies are opening a variety of attractive fields of science and technology using high energy density plasmas such as plasma physics, laboratory astrophysics, material science, nuclear science including medical applications and laser fusion. The critical issues in the applications are attributed to the control of intense light and enormous density of charged particles including efficient generation of the particles such as MeV electrons and protons with a current density of TA/cm2. Now these application possibilities are limited only by the laser technology. These applications have been limited in the control of the high power laser technologies and their optics. However, if we have another device consisted of the 4th material, i.e. plasma, we will obtain a higher energy density condition and explore the application possibilities, which could be called high energy plasma device. One of the most attractive devices has been demonstrated in the fast ignition scheme of the laser fusion, which is cone-guiding of ultra-intense laser light in to high density regions1. This is one of the applications of the plasma device to control the ultra-intense laser light. The other role of the devices consisted of transient plasmas is control of enormous energy-density particles in a fashion analogous to light control with a conventional optical device. A plasma fibre (5?m/1mm), as one example of the devices, has guided and deflected the high-density MeV electrons generated by ultra-intense laser light 2. The electrons have been well collimated with either a lens-like plasma device or a fibre-like plasma, resulting in isochoric heating and creation of ultra-high pressures such as Giga bar with an order of 100J. Plasmas would be uniquely a device to easily control the higher energy density particles like a conventional optical device as well as the ultra-intense laser light, which could be called plasma photonic device. (Author)

  15. Influence of powder pre-annealing on the phase formation and critical current of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Chen, X.P.; Grivel, Jean-Claude; Li, M.Y.

    2004-01-01

    . The effects of different precursors were investigated by XRD, SEM/EDS and critical current measurements. It has been found that both the microstructure and phase formation depended strongly on the different lead-rich phases, which determined the reactivity of the precursor. Tapes fabricated using...... the precursor with Ca2PbO4 phase (tape T1) had lower transformation rate of 2223 phase than tapes fabricated using the precursor with 3321 phase (tape T2). SEM results show that a large fraction of secondary phases with big particle size was formed in the tape T1 during the subsequent sintering, which might...

  16. Models for Experimental High Density Housing

    Science.gov (United States)

    Bradecki, Tomasz; Swoboda, Julia; Nowak, Katarzyna; Dziechciarz, Klaudia

    2017-10-01

    The article presents the effects of research on models of high density housing. The authors present urban projects for experimental high density housing estates. The design was based on research performed on 38 examples of similar housing in Poland that have been built after 2003. Some of the case studies show extreme density and that inspired the researchers to test individual virtual solutions that would answer the question: How far can we push the limits? The experimental housing projects show strengths and weaknesses of design driven only by such indexes as FAR (floor attenuation ratio - housing density) and DPH (dwellings per hectare). Although such projects are implemented, the authors believe that there are reasons for limits since high index values may be in contradiction to the optimum character of housing environment. Virtual models on virtual plots presented by the authors were oriented toward maximising the DPH index and DAI (dwellings area index) which is very often the main driver for developers. The authors also raise the question of sustainability of such solutions. The research was carried out in the URBAN model research group (Gliwice, Poland) that consists of academic researchers and architecture students. The models reflect architectural and urban regulations that are valid in Poland. Conclusions might be helpful for urban planners, urban designers, developers, architects and architecture students.

  17. Preparation and properties of high-Tc Bi-oxide superconductors

    International Nuclear Information System (INIS)

    Maeda, H.

    1989-01-01

    Bulk superconductors of Pb-doped Bi-oxide system (BSCCO) dominated with the high-Tc phase have the critical transition temperature, Tc of 110 K, and the upper critical fields, H c2 of 140 T at OK and 60 T at 77 K. A highly dense and a highly oriented microstructure is obtained by inserting an intermediate uniaxial pressing process. The critical current density, Jc at 77 K in zero field, Jc (77K,OT) of some 5000 A/cm 2 can be easily obtained by this process, and the field dependence of Jc is also improved. Flexible high-Tc BSCCO ribbons with a Jc (77K,Ot) of 1850 A/cm 2 have been successfully prepared by the combined process of doctor blade casting, cold rolling and sintering. Aq-sheeted multifilamentary wires with 1330 filaments and tapes with 30 filaments have also been successfully fabricated and the 36-filament tape shows a Jc(77K,OT) of 1050 A/cm 2 . (Auth.). 7 refs.; 7 figs

  18. High density operation in pulsator

    International Nuclear Information System (INIS)

    Klueber, O.; Cannici, B.; Engelhardt, W.; Gernhardt, J.; Glock, E.; Karger, F.; Lisitano, G.; Mayer, H.M.; Meisel, D.; Morandi, P.

    1976-03-01

    This report summarizes the results of experiments at high electron densities (>10 14 cm -3 ) which have been achieved by pulsed gas inflow during the discharge. At these densities a regime is established which is characterized by βsub(p) > 1, nsub(i) approximately nsub(e), Tsub(i) approximately Tsub(e) and tausub(E) proportional to nsub(e). Thus the toroidal magnetic field contributes considerably to the plasma confinement and the ions constitute almost half of the plasma pressure. Furthermore, the confinement is appreciably improved and the plasma becomes impermeable to hot neutrals. (orig.) [de

  19. Effects of differently hardened brass foil laminate on the electromechanical property of externally laminated CC tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Mean, Byoung Jean; Lee, Jae Hun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-12-15

    The mechanical properties of REBCO coated conductor (CC) wires under uniaxial tension are largely determined by the thick component layers in the architecture, namely, the substrate and the stabilizer or even the reinforcement layer. Depending on device applications of the CC tapes, it is necessary to reinforce thin metallic foils externally to one-side or both sides of the CC tapes. Due to the external reinforcement of brass foils, it was found that this could increase the reversible strain limit from the Cu-stabilized CC tapes. In this study, the effects of differently hardened brass foil laminate on the electromechanical property of CC tapes were investigated under uniaxial tension loading. The tensile strain dependence of the critical current (I{sub c}) was measured at 77 K and self-field. Depending on whether the I{sub c} of CC tapes were measured during loading or after unloading, a reversible strain (or stress) limit could be determined, respectively. The both-sides of the Cu-stabilized CC tapes were laminated with brass foils with different hardness, namely 1/4H, 1H and EH. From the obtained results, it showed that the yield strength of the brass laminated CC tapes with EH brass foil laminate was comparable to the one of the Cu-stabilized CC tape due to its large yield strength even though its large volume fraction. It was found that the brass foil with different hardness was mainly sensitive on the stress dependence of I{sub c}, but not on the strain sensitivity due to the residual strain induced in the laminated CC tapes during unloading.

  20. TIROA/NOAA (Television and Infrared Observation Satellite/National Oceanic and Atmospheric Administration) satellites space environment monitor archive tape documentation: 1988 update. Technical memo

    International Nuclear Information System (INIS)

    Hill, V.J.; Evans, D.S.; Sauer, H.H.

    1988-05-01

    TIROS/NOAA satellite archive tapes containing data obtained with the Medium-Energy Proton and Electron Detector (MEPED), High-Energy Proton and Alpha-Particle Detector (HEPAD), and Total-Energy Detector (TED) are described. Descriptions of the data include orbital and housekeeping details and the information needed to decode and understand the data. Specifications of the data channels are supplied, with the timing information needed to convert the data to usable information. Description of the archive tape format gives the information needed to read the tape and unpack the data. Appendices supply the retrieval routines used by the Space Environment Services Center in Boulder

  1. Control of texture in Ag and Ag-alloy substrates for superconducting tapes

    International Nuclear Information System (INIS)

    Gladstone, T.A.

    2000-01-01

    The use of a biaxially textured silver tape as a substrate for high temperature superconductor (HTS) phases is one possible route towards the fabrication of high-J c superconducting tape. Using a cold-rolling and annealing process we have reproducibly fabricated {110} textured silver which is stable up to 900 deg. C. We have found that there are two critical process requirements for the formation of this texture; a low oxygen content in the material prior to deformation, and a cold-rolling thickness reduction of less than 97%. To overcome the problems associated with the poor mechanical strength of pure silver, texture development in Ag-Mg and Ag-Hf alloys with improved mechanical properties has been studied. Heat treatments in a reducing atmosphere allow the {110} annealing texture to be obtained in Ag-0.1 wt%Mg. The recrystallization behaviour of a Ag-Pd alloy with an increased stacking fault energy was also investigated and a partial cube texture was obtained in this material. Using orientation distribution function (ODF) analysis we have shown that minor variations in the deformation texture of both pure silver and Ag-based alloys can lead to significant differences in the recrystallization textures obtained. (author)

  2. Teaching with MARC Tapes

    Directory of Open Access Journals (Sweden)

    Pauline Atherton

    1970-03-01

    Full Text Available A computer based laboratory for library science students to use in class assignments and for independent projects has been developed and used for one year at Syracuse University. MARC Pilot Project tapes formed the data base. Different computer programs and various samples of the MARC file (48,POO records, approx. were used for search and retrieval operations. Data bases, programs, and seven different class assignments are described and evaluated for their impact on library education in gen- eral and individual students and faculty in particular.

  3. Flexible asymmetric supercapacitors with high energy and high power density in aqueous electrolytes

    Science.gov (United States)

    Cheng, Yingwen; Zhang, Hongbo; Lu, Songtao; Varanasi, Chakrapani V.; Liu, Jie

    2013-01-01

    Supercapacitors with both high energy and high power densities are critical for many practical applications. In this paper, we discuss the design and demonstrate the fabrication of flexible asymmetric supercapacitors based on nanocomposite electrodes of MnO2, activated carbon, carbon nanotubes and graphene. The combined unique properties of each of these components enable highly flexible and mechanically strong films that can serve as electrodes directly without using any current collectors or binders. Using these flexible electrodes and a roll-up approach, asymmetric supercapacitors with 2 V working voltage were successfully fabricated. The fabricated device showed excellent rate capability, with 78% of the original capacitance retained when the scan rate was increased from 2 mV s-1 to 500 mV s-1. Owing to the unique composite structure, these supercapacitors were able to deliver high energy density (24 W h kg-1) under high power density (7.8 kW kg-1) conditions. These features could enable supercapacitor based energy storage systems to be very attractive for a variety of critical applications, such as the power sources in hybrid electric vehicles and the back-up powers for wind and solar energy, where both high energy density and high power density are required.Supercapacitors with both high energy and high power densities are critical for many practical applications. In this paper, we discuss the design and demonstrate the fabrication of flexible asymmetric supercapacitors based on nanocomposite electrodes of MnO2, activated carbon, carbon nanotubes and graphene. The combined unique properties of each of these components enable highly flexible and mechanically strong films that can serve as electrodes directly without using any current collectors or binders. Using these flexible electrodes and a roll-up approach, asymmetric supercapacitors with 2 V working voltage were successfully fabricated. The fabricated device showed excellent rate capability, with 78% of

  4. A study on the development of high-Tc superconducting wire

    International Nuclear Information System (INIS)

    Won, Dong Yeon; Lee, Hee Gyoun; Kim, Chan Joong

    1991-09-01

    High magnetization YBaCuO superconductor was prepared with additions of BaSnO 3 , SnO 2 and SiC by partial melt processing. Addition of BaSnO 3 increased the magnetic property of YBaCuO by flux pinning action of finely dispersed BaSnO 3 particles, while addition of SnO 2 decreased the magnetic property, because the size of particle was larger than that of BaSnO 3 . BiPbSrCaCuO superconducting tape of single filament was prepared by powder-in-tube method using silver as a shearth material. The fabrication techniques involves powder packing, swaging, drawing and cold rolling/pressing method. The final dimension of wire after drawing is 1.2mm diameter. The wire was pressed into a tape form with a thickness of 70micron and a width of 3mm. The obtained critical current density of the prepared tape was 2000A/cm 2 at 77K. (Author)

  5. Quality of life and objective outcome assessment in women with tape division after surgery for stress urinary incontinence.

    Directory of Open Access Journals (Sweden)

    Daniela Ulrich

    Full Text Available Midurethral tapes may cause long-term complications such as voiding dysfunction, groin pain, de novo urgency or mesh erosion, which necessitate a reoperation. There is a paucity of data regarding health related quality of life in patients undergoing tape removal. The aim of the study was to evaluate quality of life (QoL and objective outcome after midurethral tape division or excision.All patients who underwent a midurethral tape division for voiding difficulties, pain or therapy resistant de novo overactive bladder between 1999 and 2014 were invited for follow-up. A control group with a suburethral tape without division was established in a 1:2 ratio and matched for age, tape used and year of tape insertion. Patients completed the Kings´ Health Questionnaire (KHQ, Incontinence Outcome Questionnaire, Female Sexual Function Index Questionnaire and the Patient Global Impression of Improvement score.Tape division or excision was performed in 32 women. Overall, 15 (60% of 25 women who were alive were available for clinical examination and completed the questionnaires. Tape division was performed for voiding dysfunction (n = 7, overactive bladder (n = 2, mesh extrusion (n = 3 and ongoing pain (n = 3. Median time to tape division/excision was 10 months. Three women in the tape division group had undergone reoperation for stress urinary incontinence (SUI. At a median follow-up of 11 years (IQR 9-13 subjective SUI rate was 53% (8/15 women in the tape division group and 17% (5/30 in the control group (p = 0.016, with no significant differences in objective SUI rates between groups. With regard to quality of life, the study group had significantly worse scores in the SUI related domains role limitation, physical limitation, severity measures and social limitations (KHQ compared to the control group.Women needing tape division or excision have lower SUI related QoL scores compared to controls mostly because of higher subjective SUI rates.

  6. Some recent efforts toward high density implosions

    International Nuclear Information System (INIS)

    McClellan, G.E.

    1980-01-01

    Some recent Livermore efforts towards achieving high-density implosions are presented. The implosion dynamics necessary to compress DT fuel to 10 to 100 times liquid density are discussed. Methods of diagnosing the maximum DT density for a specific design are presented along with results to date. The dynamics of the double-shelled target with an exploding outer shell are described, and some preliminary experimental results are presented

  7. Improved GAMMA 10 tandem mirror confinement in high density plasma

    International Nuclear Information System (INIS)

    Yatsu, K.; Cho, T.; Higaki, H.; Hirata, M.; Hojo, H.; Ichimura, M.; Ishii, K.; Ishimoto, Y.; Itakura, A.; Katanuma, I.; Kohagura, J.; Minami, R.; Nakashima, Y.; Numakura, T.; Saito, T.; Saosaki, S.; Takemura, Y.; Tatematsu, Y.; Yoshida, M.; Yoshikawa, M.

    2003-01-01

    GAMMA 10 experiments have advanced in high density experiments after the last IAEA fusion energy conference in 2000 where we reported the production of the high density plasma through use of ion cyclotron range of frequency heating at a high harmonic frequency and neutral beam injection in the anchor cells. However, the diamagnetic signal of the plasma decreased when electron cyclotron resonance heating was applied for the potential formation. Recently a high density plasma has been obtained without degradation of the diamagnetic signal and with much improved reproducibility than before. The high density plasma was attained through adjustment of the spacing of the conducting plates installed in the anchor transition regions. The potential confinement of the plasma has been extensively studied. Dependences of the ion confinement time, ion-energy confinement time and plasma confining potential on plasma density were obtained for the first time in the high density region up to a density of 4x10 18 m -3 . (author)

  8. The effectiveness of Kinesio Taping on pain and disability in cervical myofascial pain syndrome

    Directory of Open Access Journals (Sweden)

    Saime Ay

    Full Text Available Abstract Objective: The aim of this study was to investigate the effectiveness of Kinesio Taping and sham Kinesio Taping on pain, pressure pain threshold, cervical range of motion, and disability in cervical myofascial pain syndrome patients (MPS. Methods: This study was designed as a randomized, double-blind placebo controlled study. Sixty-one patients with MPS were randomly assigned into two groups. Group 1 (n = 31 was treated with Kinesio Taping and group 2 (n = 30 was treated sham taping five times by intervals of 3 days for 15 days. Additionally, all patients were given neck exercise program. Patients were evaluated according to pain, pressure pain threshold, cervical range of motion and disability. Pain was assessed by using Visual Analog Scale, pressure pain threshold was measured by using an algometer, and active cervical range of motion was measured by using goniometry. Disability was assessed with the neck pain disability index disability. Measurements were taken before and after the treatment. Results: At the end of the therapy, there were statistically significant improvements on pain, pressure pain threshold, cervical range of motion, and disability (p 0.05. Conclusion: This study shows that Kinesio Taping leads to improvements on pain, pressure pain threshold and cervical range of motion, but not disability in short time. Therefore, Kinesio Taping can be used as an alternative therapy method in the treatment of patients with MPS.

  9. Effects of Patellofemoral Taping on Patellofemoral Joint Alignment and Contact Area During Weight Bearing.

    Science.gov (United States)

    Ho, Kai-Yu; Epstein, Ryan; Garcia, Ron; Riley, Nicole; Lee, Szu-Ping

    2017-02-01

    Study Design Controlled laboratory study. Background Although it has been theorized that patellofemoral joint (PFJ) taping can correct patellar malalignment, the effects of PFJ taping techniques on patellar alignment and contact area have not yet been studied during weight bearing. Objective To examine the effects of 2 taping approaches (Kinesio and McConnell) on PFJ alignment and contact area. Methods Fourteen female subjects with patellofemoral pain and PFJ malalignment participated. Each subject underwent a pretaping magnetic resonance imaging (MRI) scan session and 2 MRI scan sessions after the application of the 2 taping techniques, which aimed to correct lateral patellar displacement. Subjects were asked to report their pain level prior to each scan session. During MRI assessment, subjects were loaded with 25% of body weight on their involved/more symptomatic leg at 0°, 20°, and 40° of knee flexion. The outcome measures included patellar lateral displacement (bisect-offset [BSO] index), mediolateral patellar tilt angle, patellar height (Insall-Salvati ratio), contact area, and pain. Patellofemoral joint alignment and contact area were compared among the 3 conditions (no tape, Kinesio, and McConnell) at 3 knee angles using a 2-factor, repeated-measures analysis of variance. Pain was compared among the 3 conditions using the Friedman test and post hoc Wilcoxon signed-rank tests. Results Our data did not reveal any significant effects of either McConnell or Kinesio taping on the BSO index, patellar tilt angle, Insall-Salvati ratio, or contact area across the 3 knee angles, whereas knee angle had a significant effect on the BSO index and contact area. A reduction in pain was observed after the application of the Kinesio taping technique. Conclusion In a weight-bearing condition, this preliminary study did not support the use of PFJ taping as a medial correction technique to alter the PFJ contact area or alignment of the patella. J Orthop Sports Phys Ther 2017

  10. Critical current anisotropy in Ag/(Pb,Bi){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10+x} multifilamentary tapes: influence of self-magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Majoros, M [IRC in Superconductivity, University of Cambridge, Cambridge (United Kingdom); Institute of Electrical Engineering, Slovak Academy of Sciences, Bratislava (Slovakia); Glowacki, B A [IRC in Superconductivity, University of Cambridge, Cambridge (United Kingdom); Department of Materials Science and Metallurgy, University of Cambridge, Cambridge (United Kingdom); Campbell, A M [IRC in Superconductivity, University of Cambridge, Cambridge (United Kingdom)

    2001-06-01

    Two factors affect critical current anisotropy in multifilamentary Ag/(Pb,Bi){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10+x} tapes - the intrinsic material anisotropy and the geometry. Experimental results on the magnetic field dependence and anisotropy of the critical current in a multifilamentary Ag/(Pb,Bi){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10+x} tape after correction for self-magnetic field effects were found to fit the anisotropic Kim relation. Based on this relation a finite-element-method numerical code for solving the nonlinear Poisson equation for vector magnetic potential was adopted. It allowed the experimental data to be reproduced by back calculation and made possible the study of the interplay of self and external magnetic fields in different cases with well defined physical parameters of the material. The model was used to analyse the distribution of the critical current in individual filaments as well as to evaluate the influence of their geometrical arrangements on the critical current of the tape. The self-field critical current of an individual filament 'extracted' from the tape was compared with the critical current of the overall tape. The effect of the self-magnetic field on critical current distribution obtained by the cutting method was determined. The critical currents of the tapes with different cross sections were calculated and compared with experiments and the influence of the self-field was analysed. The anisotropic properties of a low anisotropy architecture of a multifilamentary Ag/(Pb,Bi){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10+x} conductor were studied. The dependence of critical currents (normalized to self-field critical currents) on external magnetic field corrected for the self-field was found to follow nearly the same curves as those for tapes with different critical current densities (in the range 20-70 kA cm{sup -2} in a self-field), which makes the numerical model applicable to different tapes. (author)

  11. High-density limit of quantum chromodynamics

    International Nuclear Information System (INIS)

    Alvarez, E.

    1983-01-01

    By means of a formal expansion of the partition function presumably valid at large baryon densities, the propagator of the quarks is expressed in terms of the gluon propagator. This result is interpreted as implying that correlations between quarks and gluons are unimportant at high enough density, so that a kind of mean-field approximation gives a very accurate description of the physical system

  12. Low back pain during pregnancy and Kinesio tape application.

    Science.gov (United States)

    Reyhan, Aycan Çakmak; Dereli, Elif Elçin; Çolak, Tuğba Kuru

    2017-01-01

    Low back pain is a common problem during pregnancy. Although the pain usually occurs in the third trimester, it might be seen in the first trimester, too. There are various types of applications for the treatment of low back pain during pregnancy. However, there is a lack of evidence for the effectiveness of each method. If there is not an obvious deficit, bed rest, exercise, conventional physiotherapy, using protective principles for the lumbar area are recommended, since the main and the only complaint is low back pain. It is aimed in the current review to investigate the use of Kinesio tape in the low back pain seen during pregnancy and to review the literature related to this subject. There are only a few studies investigating the effect of Kinesio tape during pregnancy in the literature and they mostly did not aim to study the low back pain, further evidence and studies are needed to investigate the use of Kinesio tape for the low back pain seen during pregnancy as there is not evidence strong enough. Kinesiotape application aims to increase circulation and mobility, and regarding these gains decreased pain and increased performance are expected.

  13. Fueling with edge recycling to high-density in DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, A.W., E-mail: leonard@fusion.gat.com [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Elder, J.D. [University of Toronto Institute of Aerospace Studies, Toronto, Canada M3H 5T6 (Canada); Canik, J.M. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Groebner, R.J.; Osborne, T.H. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States)

    2013-07-15

    Pedestal fueling through edge recycling is examined with the interpretive OEDGE code for high-density discharges in DIII-D. A high current, high-density discharge is found to have a similar radial ion flux profile through the pedestal to a lower current, lower density discharge. The higher density discharge, however, has a greater density gradient indicating a pedestal particle diffusion coefficient that scales near linear with 1/I{sub p}. The time dependence of density profile is taken into account in the analysis of a discharge with low frequency ELMs. The time-dependent analysis indicates that the inferred neutral ionization source is inadequate to account for the increase in the density profile between ELMs, implying an inward density convection, or density pinch, near the top of the pedestal.

  14. Short-Term Effects of Kinesio Taping on Muscle Recruitment Order During a Vertical Jump: A Pilot Study.

    Science.gov (United States)

    Mendez-Rebolledo, Guillermo; Ramirez-Campillo, Rodrigo; Guzman-Muñoz, Eduardo; Gatica-Rojas, Valeska; Dabanch-Santis, Alexis; Diaz-Valenzuela, Francisco

    2018-06-22

    Kinesio taping is commonly used in sports and rehabilitation settings with the aim of prevention and treatment of musculoskeletal injuries. However, limited evidence exists regarding the effects of 24 and 72 hours of kinesio taping on trunk and lower limb neuromuscular and kinetic performance during a vertical jump. The purpose of this study was to analyze the short-term effects of kinesio taping on height and ground reaction force during a vertical jump, in addition to trunk and lower limb muscle latency and recruitment order. Single-group pretest-posttest. University laboratory. Twelve male athletes from different sports (track and field, basketball, and soccer). They completed a single squat and countermovement jump at basal time (no kinesio taping), 24, and 72 hours of kinesio taping application on the gluteus maximus, biceps femoris, rectus femoris, gastrocnemius medialis, and longissimus. Muscle onset latencies were assessed by electromyography during a squat and countermovement jump, in addition to measurements of the jump height and normalized ground reaction force. The kinesio taping had no effect after 24 hours on either the countermovement or squat jump. However, at 72 hours, the kinesio taping increased the jump height (P = .02; d = 0.36) and normalized ground reaction force (P = .001; d = 0.45) during the countermovement jump. In addition, 72-hour kinesio taping reduced longissimus onset latency (P = .03; d = 1.34) and improved muscle recruitment order during a countermovement jump. These findings suggest that kinesio taping may improve neuromuscular and kinetic performance during a countermovement jump only after 72 hours of application on healthy and uninjured male athletes. However, no changes were observed on a squat jump. Future studies should incorporate a control group to verify kinesio taping's effects and its influence on injured athletes.

  15. Low density, variation in sintered density and high nitrogen in uranium dioxide

    International Nuclear Information System (INIS)

    Balakrishna, Palanki; Murty, B.N.; Anuradha, M.; Nageshwara Rao, P.; Jayaraj, R.N.; Ganguly, C.

    2000-01-01

    Low sintered density and density variation in sintered UO 2 were found to have been caused by non uniformity in the granule feed characteristics to the compacting press. The nitrogen impurity content of sintered UO 2 was found to be sintering furnace related and associated with low sintered density pellets. The problems of low density, variation in sintered density and high nitrogen could be solved by the replacement of the prevailing four punch precompaction by a single punch process; by the introduction of a vibro-sieve for the separation of fine particles from the press feed granules; by innovation in the powder feed shoe design for simultaneous and uniform dispensing of powder in all the die holes; by increasing the final compaction pressure and by modifying the gas flows and preheat temperature in the sintering furnace. (author)

  16. Functionally Graded Ceramics Fabricated with Side-by-Side Tape Casting for Use in Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Bulatova, Regina; Bahl, Christian; Andersen, Kjeld Bøhm

    2015-01-01

    Functionally graded ceramic tapes have been fabricated by a side-by-side tape casting technique. This study shows the possibility and describes the main principles of adjacent coflow of slurries resulting in formation of thin plates of graded ceramic material. Results showed that the small...... variations of solvent and binder system concentrations have a substantial effect on slurry viscosity. Varying these parameters showed that side-by-side tape casting with a well-defined interface area is possible for slurries with viscosities above 3500 mPa s at a casting shear rate of 3.3 s -1...... of developing this graded ceramic tape casting was applications of these specific magnetocaloric properties within the magnetic refrigeration technology....

  17. High throughput nonparametric probability density estimation.

    Science.gov (United States)

    Farmer, Jenny; Jacobs, Donald

    2018-01-01

    In high throughput applications, such as those found in bioinformatics and finance, it is important to determine accurate probability distribution functions despite only minimal information about data characteristics, and without using human subjectivity. Such an automated process for univariate data is implemented to achieve this goal by merging the maximum entropy method with single order statistics and maximum likelihood. The only required properties of the random variables are that they are continuous and that they are, or can be approximated as, independent and identically distributed. A quasi-log-likelihood function based on single order statistics for sampled uniform random data is used to empirically construct a sample size invariant universal scoring function. Then a probability density estimate is determined by iteratively improving trial cumulative distribution functions, where better estimates are quantified by the scoring function that identifies atypical fluctuations. This criterion resists under and over fitting data as an alternative to employing the Bayesian or Akaike information criterion. Multiple estimates for the probability density reflect uncertainties due to statistical fluctuations in random samples. Scaled quantile residual plots are also introduced as an effective diagnostic to visualize the quality of the estimated probability densities. Benchmark tests show that estimates for the probability density function (PDF) converge to the true PDF as sample size increases on particularly difficult test probability densities that include cases with discontinuities, multi-resolution scales, heavy tails, and singularities. These results indicate the method has general applicability for high throughput statistical inference.

  18. AC magnetic losses in Bi-2223/Ag tapes with different aspect ratios

    Energy Technology Data Exchange (ETDEWEB)

    Fang, J.; Luo, X.M.; Chen, D.X.; Collings, E.W.; Lee, E.; Sumption, M.D.; Alamgir, A.K.M.; Yi, H.P.; Fang, J.G.; Gu, C.; Guo, S.Q.; Liu, M.L.; Xin, Y.; Han, Z

    2004-10-01

    AC losses in multi-filamentary tapes depend on various parameters. Among them, the overall tape width and thickness are expected to have an important influence. In order to study this geometrical effect, five Bi-2223/Ag tapes with different aspect ratios from 5 to 26 have been prepared. AC losses have been measured at 77 K when a perpendicular AC magnetic field is applied. It has been found that at any frequencies the magnetic loss per cycle increases as the aspect ratio increases. For AC magnetic loss, with increasing frequency from 3 to 9000 Hz the losses as a function of frequency show a maximum if the field amplitude is much less than the full penetration field or increase continuously if the field amplitude is larger.

  19. AC magnetic losses in Bi-2223/Ag tapes with different aspect ratios

    International Nuclear Information System (INIS)

    Fang, J.; Luo, X.M.; Chen, D.X.; Collings, E.W.; Lee, E.; Sumption, M.D.; Alamgir, A.K.M.; Yi, H.P.; Fang, J.G.; Gu, C.; Guo, S.Q.; Liu, M.L.; Xin, Y.; Han, Z.

    2004-01-01

    AC losses in multi-filamentary tapes depend on various parameters. Among them, the overall tape width and thickness are expected to have an important influence. In order to study this geometrical effect, five Bi-2223/Ag tapes with different aspect ratios from 5 to 26 have been prepared. AC losses have been measured at 77 K when a perpendicular AC magnetic field is applied. It has been found that at any frequencies the magnetic loss per cycle increases as the aspect ratio increases. For AC magnetic loss, with increasing frequency from 3 to 9000 Hz the losses as a function of frequency show a maximum if the field amplitude is much less than the full penetration field or increase continuously if the field amplitude is larger

  20. Modeling the current distribution in HTS tapes with transport current and applied magnetic field

    NARCIS (Netherlands)

    Yazawa, T.; Yazawa, Takashi; Rabbers, J.J.; Chevtchenko, O.A.; ten Haken, Bernard; ten Kate, Herman H.J.; Maeda, Hideaki

    1999-01-01

    A numerical model is developed for the current distribution in a high temperature superconducting (HTS) tape, (Bi,Pb)2Sr2 Ca2Cu3Ox-Ag, subjected to a combination of a transport current and an applied magnetic field. This analysis is based on a two-dimensional formulation of Maxwell's equations in

  1. LANDSAT-D data format control book. Volume 6, appendix G: GSFC HDT-AM inventory tape (GHIT-AM)

    Science.gov (United States)

    1981-01-01

    The data format specifications of the Goddard HDT inventory tapes (GHITS), which accompany shipments of archival digital multispectral scanner image data (HDT-AM tapes), are defined. The GHIT is a nine-track, 1600-BPI tape which conforms to the ANSI standard and serves as an inventory and description of the image data included in the shipment. The archival MSS tapes (HDT-AMs) contain radiometrically corrected but geometrically uncorrected image data plus certain ancillary data necessary to perform the geometric corrections.

  2. The effectiveness of Kinesio Taping on pain and disability in cervical myofascial pain syndrome.

    Science.gov (United States)

    Ay, Saime; Konak, Hatice Ecem; Evcik, Deniz; Kibar, Sibel

    The aim of this study was to investigate the effectiveness of Kinesio Taping and sham Kinesio Taping on pain, pressure pain threshold, cervical range of motion, and disability in cervical myofascial pain syndrome patients (MPS). This study was designed as a randomized, double-blind placebo controlled study. Sixty-one patients with MPS were randomly assigned into two groups. Group 1 (n=31) was treated with Kinesio Taping and group 2 (n=30) was treated sham taping five times by intervals of 3 days for 15 days. Additionally, all patients were given neck exercise program. Patients were evaluated according to pain, pressure pain threshold, cervical range of motion and disability. Pain was assessed by using Visual Analog Scale, pressure pain threshold was measured by using an algometer, and active cervical range of motion was measured by using goniometry. Disability was assessed with the neck pain disability index disability. Measurements were taken before and after the treatment. At the end of the therapy, there were statistically significant improvements on pain, pressure pain threshold, cervical range of motion, and disability (pdisability (p>0.05). This study shows that Kinesio Taping leads to improvements on pain, pressure pain threshold and cervical range of motion, but not disability in short time. Therefore, Kinesio Taping can be used as an alternative therapy method in the treatment of patients with MPS. Copyright © 2016 Elsevier Editora Ltda. All rights reserved.

  3. Highly efficient red electrophosphorescent devices at high current densities

    International Nuclear Information System (INIS)

    Wu Youzhi; Zhu Wenqing; Zheng Xinyou; Sun, Runguang; Jiang Xueyin; Zhang Zhilin; Xu Shaohong

    2007-01-01

    Efficiency decrease at high current densities in red electrophosphorescent devices is drastically restrained compared with that from conventional electrophosphorescent devices by using bis(2-methyl-8-quinolinato)4-phenylphenolate aluminum (BAlq) as a hole and exciton blocker. Ir complex, bis(2-(2'-benzo[4,5-α]thienyl) pyridinato-N,C 3' ) iridium (acetyl-acetonate) is used as an emitter, maximum external quantum efficiency (QE) of 7.0% and luminance of 10000cd/m 2 are obtained. The QE is still as high as 4.1% at higher current density J=100mA/cm 2 . CIE-1931 co-ordinates are 0.672, 0.321. A carrier trapping mechanism is revealed to dominate in the process of electroluminescence

  4. Does taping in addition to physiotherapy improve the outcomes in subacromial impingement syndrome? A systematic review.

    Science.gov (United States)

    Saracoglu, Ismail; Emuk, Yusuf; Taspinar, Ferruh

    2018-04-01

    Taping is used with or without other interventions for many purposes, especially to manage pain and improve functional activity in patients with shoulder pain. The aim of this review was to determine whether any taping technique in addition to physiotherapy care is more effective than physiotherapy care alone in patients with shoulder impingement syndrome. A systematic search of Cochrane Database of Systematic Review, MEDLINE (EBSCO), Physiotherapy Evidence Database (PEDro), CINAHL (EBSCO), PUBMED, AMED, EMBASE (OVID), The Kinesio Kinesio® Taping Method, Kinesio® Tex Tape UK and International websites ( www.kinesiotaping.co.uk ; www.kinesiotaping.com ) was conducted to June 2015. The outcome measures were pain, disability, range of motion and muscle strength. As data were not suitable for meta-analysis, narrative synthesis were applied. Three randomized controlled trials and one controlled trial (135 patients) were included. The results were conflicting and weak on the effectiveness of taping as an adjunct therapy for improvement of pain, disability, range of motion and muscle strength. Clinical taping in addition to physiotherapy interventions (e.g. exercise, electrotherapy, and manual therapy) might be an optional modality for managing patients with shoulder impingement syndrome, especially for the initial stage of the treatment; however, we need further robust, placebo controlled and consistent studies to prove whether it is more effective than physiotherapy interventions without taping.

  5. Fundamental properties of high-quality carbon nanofoam: from low to high density

    Directory of Open Access Journals (Sweden)

    Natalie Frese

    2016-12-01

    Full Text Available Highly uniform samples of carbon nanofoam from hydrothermal sucrose carbonization were studied by helium ion microscopy (HIM, X-ray photoelectron spectroscopy (XPS, and Raman spectroscopy. Foams with different densities were produced by changing the process temperature in the autoclave reactor. This work illustrates how the geometrical structure, electron core levels, and the vibrational signatures change when the density of the foams is varied. We find that the low-density foams have very uniform structure consisting of micropearls with ≈2–3 μm average diameter. Higher density foams contain larger-sized micropearls (≈6–9 μm diameter which often coalesced to form nonspherical μm-sized units. Both, low- and high-density foams are comprised of predominantly sp2-type carbon. The higher density foams, however, show an advanced graphitization degree and a stronger sp3-type electronic contribution, related to the inclusion of sp3 connections in their surface network.

  6. High-density housing that works for all

    Energy Technology Data Exchange (ETDEWEB)

    Hasan, Arif

    2010-03-15

    In an urbanising world, the way people fit into cities is vastly important - socially, economically, environmentally, even psychologically. So density, or the number of people living in a given area, is central to urban design and planning. Both governments and markets tend to get density wrong, leading to overcrowding, urban sprawl or often both. A case in point are the high-rise buildings springing up throughtout urban Asia - perceived as key features of that widely touted concept, the 'world-class city'. While some may offer a viable solution to land pressures and density requirements, many built to house evicted or resettled 'slum' dwellers are a social and economic nightmare - inconveniently sited, overcrowded and costly. New evidence from Karachi, Pakistan, reveals a real alternative. Poor people can create liveable high-density settlements as long as community control, the right technical assistance and flexible designs are in place. A city is surely 'world-class' only when it is cosmopolitan – built to serve all, including the poorest.

  7. Artificial Intelligence Controls Tape-Recording Sequence

    Science.gov (United States)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  8. High density high performance plasma with internal diffusion barrier in Large Helical Device

    International Nuclear Information System (INIS)

    Sakamoto, R.; Kobayashi, M.; Miyazawa, J.

    2008-10-01

    A attractive high density plasma operational regime, namely an internal diffusion barrier (IDB), has been discovered in the intrinsic helical divertor configuration on the Large Helical Device (LHD). The IDB which enables core plasma to access a high density/high pressure regime has been developed. It is revealed that the IDB is reproducibly formed by pellet fueling in the magnetic configurations shifted outward in major radius. Attainable central plasma density exceeds 1x10 21 m -3 . Central pressure reaches 1.5 times atmospheric pressure and the central β value becomes fairly high even at high magnetic field, i.e. β(0)=5.5% at B t =2.57 T. (author)

  9. History and operation of INIS magnetic tape retrieval service in CSSR

    International Nuclear Information System (INIS)

    Blazek, J.

    The Nuclear Information Centre is responsible for the utilization of the INIS magnetic tape in Czechoslovakia as the country's national INIS centre. The tape has been used since 1974 for selective dissemination of information using an EC 1040 computer. Currently, users are provided with SDI searches, their copies (the so-called parasite searches) and retrospective searches. The organization of INIS-SDI services is described and the results are reported of the poll among the users of the services. (Ha)

  10. Analysis of transient state in HTS tapes under ripple DC load current

    Science.gov (United States)

    Stepien, M.; Grzesik, B.

    2014-05-01

    The paper concerns the analysis of transient state (quench transition) in HTS tapes loaded with the current having DC component together with a ripple component. Two shapes of the ripple were taken into account: sinusoidal and triangular. Very often HTS tape connected to a power electronic current supply (i.e. superconducting coil for SMES) that delivers DC current with ripples and it needs to be examined under such conditions. Additionally, measurements of electrical (and thermal) parameters under such ripple excitation is useful to tape characterization in broad range of load currents. The results presented in the paper were obtained using test bench which contains programmable DC supply and National Instruments data acquisition system. Voltage drops and load currents were measured vs. time. Analysis of measured parameters as a function of the current was used to tape description with quench dynamics taken into account. Results of measurements were also used to comparison with the results of numerical modelling based on FEM. Presented provisional results show possibility to use results of measurements in transient state to prepare inverse models of superconductors and their detailed numerical modelling.

  11. High density data recording for SSCL linac

    International Nuclear Information System (INIS)

    VanDeusen, A.L.; Crist, C.

    1993-01-01

    The Superconducting Super Collider Laboratory and AlliedSignal Aerospace have collaboratively developed a high density data monitoring system for beam diagnostic activities. The 128 channel data system is based on a custom multi-channel high speed digitizer card for the VXI bus. The card is referred to as a Modular Input VXI (MIX) digitizer. Multiple MIX cards are used in the complete system to achieve the necessary high channel density requirements. Each MIX digitizer card also contains programmable signal conditioning, and enough local memory to complete an entire beam scan without assistance from the host processor

  12. Characterization of the high density plasma etching process of CCTO thin films for the fabrication of very high density capacitors

    International Nuclear Information System (INIS)

    Altamore, C; Tringali, C; Sparta', N; Marco, S Di; Grasso, A; Ravesi, S

    2010-01-01

    In this work the feasibility of CCTO (Calcium Copper Titanate) patterning by etching process is demonstrated and fully characterized in a hard to etch materials etcher. CCTO sintered in powder shows a giant relative dielectric constant (10 5 ) measured at 1 MHz at room temperature. This feature is furthermore coupled with stability from 10 1 Hz to 10 6 Hz in a wide temperature range (100K - 600K). In principle, this property can allow to fabricate very high capacitance density condenser. Due to its perovskite multi-component structure, CCTO can be considered a hard to etch material. For high density capacitor fabrication, CCTO anisotropic etching is requested by using high density plasma. The behavior of etched CCTO was studied in a HRe- (High Density Reflected electron) plasma etcher using Cl 2 /Ar chemistry. The relationship between the etch rate and the Cl 2 /Ar ratio was also studied. The effects of RF MHz, KHz Power and pressure variation, the impact of HBr addiction to the Cl 2 /Ar chemistry on the CCTO etch rate and on its selectivity to Pt and photo resist was investigated.

  13. Characterization of the high density plasma etching process of CCTO thin films for the fabrication of very high density capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Altamore, C; Tringali, C; Sparta' , N; Marco, S Di; Grasso, A; Ravesi, S [STMicroelectronics, Industial and Multi-segment Sector R and D, Catania (Italy)

    2010-02-15

    In this work the feasibility of CCTO (Calcium Copper Titanate) patterning by etching process is demonstrated and fully characterized in a hard to etch materials etcher. CCTO sintered in powder shows a giant relative dielectric constant (10{sup 5}) measured at 1 MHz at room temperature. This feature is furthermore coupled with stability from 10{sup 1} Hz to 10{sup 6} Hz in a wide temperature range (100K - 600K). In principle, this property can allow to fabricate very high capacitance density condenser. Due to its perovskite multi-component structure, CCTO can be considered a hard to etch material. For high density capacitor fabrication, CCTO anisotropic etching is requested by using high density plasma. The behavior of etched CCTO was studied in a HRe- (High Density Reflected electron) plasma etcher using Cl{sub 2}/Ar chemistry. The relationship between the etch rate and the Cl{sub 2}/Ar ratio was also studied. The effects of RF MHz, KHz Power and pressure variation, the impact of HBr addiction to the Cl{sub 2}/Ar chemistry on the CCTO etch rate and on its selectivity to Pt and photo resist was investigated.

  14. Compensated readout for high-density MOS-gated memristor crossbar array

    KAUST Repository

    Zidan, Mohammed A.

    2015-01-01

    Leakage current is one of the main challenges facing high-density MOS-gated memristor arrays. In this study, we show that leakage current ruins the memory readout process for high-density arrays, and analyze the tradeoff between the array density and its power consumption. We propose a novel readout technique and its underlying circuitry, which is able to compensate for the transistor leakage-current effect in the high-density gated memristor array.

  15. Critical Current Properties of HTS Twisted Stacked-Tape Cable in Subcooled- and Pressurized-Liquid Nitrogen

    International Nuclear Information System (INIS)

    Tomita, M; Suzuki, K; Fukumoto, Y; Ishihara, A; Akasaka, T; Kobayashi, Y; Maeda, A; Takayasu, M

    2015-01-01

    A 2 m length Twisted Stacked-Tape Cable (TSTC) conductor which was fabricated by 32-YBCO-tapes (4 mm width) with a 200 mm twist pitch was investigated at various temperatures near 77 K in subcooled- and pressurized-liquid nitrogen. The critical current of the TSTC cable which was 1.45 kA at 77 K measured from 64 K to 85 K by controlling the equilibrium vapor pressure of nitrogen bath and were varied from 3.65 kA at 64 K to 0.42 kA at 85 K. The temperature dependence of cables’ critical current agrees with that of the 4 mm width YBCO tape. These results are encouraging for applications of a compact Twisted Stacked-Tape Cable application in railway systems. (paper)

  16. Fabrication and Characterization of Graded Anodes for Anode-Supported Solid Oxide Fuel Cells by Tape Casting and Lamination

    DEFF Research Database (Denmark)

    Beltran-Lopez, J.F.; Laguna-Bercero, M.A.; Gurauskis, Jonas

    2014-01-01

    Graded anodes for anode-supported solid oxide fuel cells (SOFCs) are fabricated by tape casting and subsequent cold lamination of plates using different compositions. Rheological parameters are adjusted to obtain stable suspensions for tape casting. The conditions for the tape casting and laminat......Graded anodes for anode-supported solid oxide fuel cells (SOFCs) are fabricated by tape casting and subsequent cold lamination of plates using different compositions. Rheological parameters are adjusted to obtain stable suspensions for tape casting. The conditions for the tape casting...... and lamination will be described. Flexural strength of the reduced cermets measured using three-point bending configuration is 468±37MPa. The graded anode supports are characterized by scanning electron microscope observations, mercury porosimetry intrusion, and resistivity measurements, showing an adequate...... of tapes at room temperature without using plasticizers. This is made by the combination of two different binders with varying Tg (glass transition temperature) which resulted in plastic deformation at room temperature. Those results indicate that the proposed process is a cost-effective method...

  17. Numerical analysis of energy density and particle density in high energy heavy-ion collisions

    International Nuclear Information System (INIS)

    Fu Yuanyong; Lu Zhongdao

    2004-01-01

    Energy density and particle density in high energy heavy-ion collisions are calculated with infinite series expansion method and Gauss-Laguerre formulas in numerical integration separately, and the results of these two methods are compared, the higher terms and linear terms in series expansion are also compared. The results show that Gauss-Laguerre formulas is a good method in calculations of high energy heavy-ion collisions. (author)

  18. Correlation between in-field critical currents in Zr-added (Gd, Y)Ba2Cu3Ox superconducting tapes at 30 and 77 K

    International Nuclear Information System (INIS)

    Selvamanickam, V; Xu, A; Liu, Y; Khatri, N D; Galstyan, E; Majkic, G; Lei, C; Chen, Y

    2014-01-01

    Critical current (I c ) values of 1384 A/12 mm, corresponding to a critical current density of 12.47 MA cm −2 and a pinning force of 374 GN m −3 , have been achieved at 30 K, 3 T in the orientation of field parallel to the c axis (B ∥ c) in (Gd, Y)BaCuO tapes with 15 mol% Zr addition made by metal organic chemical vapor deposition (MOCVD). These tapes show pinning force levels as high as 453 GN m −3 at 30 K. An analysis of the properties of 24–28 (Gd, Y)BaCuO tapes with 15 mol% Zr addition showed a lack of correlation between their critical currents at 30 K, 3 T (B ∥ c) and I c values both at 77 K, zero field and at 77 K, 1 T (B ∥ c). However, a strong correlation was found between the critical currents at 30 K, 3 T and at 77 K, 3 T (B ∥ c). It has also been discovered that the minimum critical current (I c, min ) value at 77 K, 3 T has no influence on the I c, min value at 30 K, 3 T, and it in turn depends on the ratio of the I c values in the orientations of field parallel and perpendicular to the c axis at 77 K, 3 T. (paper)

  19. Chronic vaginal discharge and left leg edema after a transobturator tape procedure.

    Science.gov (United States)

    Kim, Tae-Hee; Lee, Hae-Hyeog; Kim, Jun-Mo

    2014-05-01

    We report on a patient who underwent total vaginal hysterectomy for urinary incontinence 8 years previously with a sling operation using transobturator tape (TOT). She was admitted to our hospital after complaints of vaginal discharge, foul odor, and bleeding, left thigh pain, and edema. Magnetic resonance imaging (MRI) and computed tomography (CT) revealed a fistula tract from the vagina or urethra with remnant sling tape. We removed the remnant tape using intraoperative ultrasonography. This case exemplifies the rare occurrence of a vaginal fistula extending to the obturator, adductor, and pectineus muscles combined with myositis after TOT placement. It is important that urogynecologists recognize that TOT procedures may result in complications accompanied by common recurrent vaginal symptoms, such as vaginal odor and spotting, which can be identified by MRI or CT.

  20. Effect of sheath material on critical current characteristics of MgB2 at high temperatures

    International Nuclear Information System (INIS)

    Kiuchi, M.; Yamauchi, K.; Kurokawa, T.; Otabe, E.S.; Matsushita, T.; Okada, M.; Tanaka, K.; Kumakura, H.; Kitaguchi, H.

    2004-01-01

    Critical current density and irreversibility field were measured at various temperatures and magnetic fields for MgB 2 PIT tape specimens with different sheaths materials. The experimental results were compared with theoretical estimations using the flux creep-flow model. It is found that the hardness of sheath material indirectly affects the pinning property only through the packing density of MgB 2 . It is considered that the critical current density is mainly determined by a low value of distributed local critical current density determined by grain connectivity. On the other hand, the irreversibility field which is approximately the same among the three tapes is mainly determined by the average pinning strength

  1. NdFeB thick films prepared by tape casting

    International Nuclear Information System (INIS)

    Pawlowski, B.; Schwarzer, S.; Rahmig, A.; Toepfer, J.

    2003-01-01

    NdFeB films of thickness between 100 and 800 μm were prepared by tape casting of a slurry containing 84-95 wt% of commercial NdFeB powder (MQP-B, -Q and -S). After curing the flexible green tapes at 120 deg. C non-porous magnetic films are obtained. The remanence of the films is in the range of 350-450 mT and the coercivity is between 300 and 800 kA/m depending on the type of MQP powder used. The magnetic properties of the films are discussed in relation to film composition and type of magnetic material. For MEMS applications the thick films are magnetized with a multi-pole stripe pattern with 1 mm pole pitch. The induction at the surface of the films was measured with a Hall probe and compared to theoretical calculations. The results indicate that the films are completely magnetized regardless of the film thickness. Tape-casted NdFeB thick films are promising candidates for applications in micro-systems or actuators. Miniaturization of the magnet components is one of the key issues in the development of electromagnetic micro-systems, thus creating a need for replacement of small sintered magnets by magnetic thick film components. Other applications include encoders

  2. The new CERN tape software - getting ready for total performance

    CERN Document Server

    Cano, E; Kruse, D F; Kotlyar, V; Côme, D

    2015-01-01

    CASTOR (the CERN Advanced STORage system) is used to store the custodial copy of all of the physics data collected from the CERN experiments, both past and present. CASTOR is a hierarchical storage management system that has a disk-based front-end and a tape-based back-end. The software responsible for controlling the tape back-end has been redesigned and redeveloped over the last year and was put in production at the beginning of 2015. This paper summarises the motives behind the redesign, describes in detail the redevelopment work and concludes with the short and long-term benefits.

  3. High density regimes and beta limits in JET

    International Nuclear Information System (INIS)

    Smeulders, P.

    1990-01-01

    Results are first presented on the density limit in JET discharges with graphite (C), Be gettered graphite and Be limiters. There is a clear improvement in the case of Be limiters. The Be gettered phase showed no increase in the gas fueled density limit, except with Ion Cyclotron Resonance Heating (ICRH), but, the limit changed character. During MARFE-formation, any further increase in density was prevented, leading to a soft density limit. The soft density limit was a function of input power and impurity content with a week dependence on q. Helium and pellet fuelled discharges exceeded the gas-fuelled global density limits, but essentially had the same edge limit. In the second part, results are presented of high β operation in low-B Double-Null (DN) X-point configurations with Be-gettered carbon target plates. The Troyon limit was reached during H-mode discharges and toroidal β values of 5.5% were obtained. At high beta, the sawteeth were modified and characterised by very rapid heat-waves and fishbone-like pre- and post-cursors with strongly ballooning character. 17 refs., 5 figs

  4. Delayed latency of peroneal reflex to sudden inversion with ankle taping or bracing.

    Science.gov (United States)

    Shima, N; Maeda, A; Hirohashi, K

    2005-01-01

    The purpose of the present study was to examine the effects of ankle taping and bracing based on the peroneal reflex in the hypermobile and normal ankle joints with and without history of ankle injury. Thirty-six ankle joints of 18 collegiate American football athletes with and without previous history of injury were studied. The angle of talar tilt (TT) was measured by stress radiograph for classifying normal (TT5 degrees ) ankles. They were tested with taping, bracing, and without any supports as a control. The latency of peroneus longus muscle was measured by a sudden inversion of 25 degrees using surface EMG signals. The results of the present study show no significant three-way Group (hypermobile or normal ankles) by History (previously injured or uninjured ankles) by Condition (control, taping, or bracing) interaction, while Condition main effect was significant (p0.05). In conclusion, ankle taping and bracing delayed the peroneal reflex latency not only for hypermobile ankles and/or injured ankle joints but also for intact ankle joints.

  5. The use of low density high accuracy (LDHA) data for correction of high density low accuracy (HDLA) point cloud

    Science.gov (United States)

    Rak, Michal Bartosz; Wozniak, Adam; Mayer, J. R. R.

    2016-06-01

    Coordinate measuring techniques rely on computer processing of coordinate values of points gathered from physical surfaces using contact or non-contact methods. Contact measurements are characterized by low density and high accuracy. On the other hand optical methods gather high density data of the whole object in a short time but with accuracy at least one order of magnitude lower than for contact measurements. Thus the drawback of contact methods is low density of data, while for non-contact methods it is low accuracy. In this paper a method for fusion of data from two measurements of fundamentally different nature: high density low accuracy (HDLA) and low density high accuracy (LDHA) is presented to overcome the limitations of both measuring methods. In the proposed method the concept of virtual markers is used to find a representation of pairs of corresponding characteristic points in both sets of data. In each pair the coordinates of the point from contact measurements is treated as a reference for the corresponding point from non-contact measurement. Transformation enabling displacement of characteristic points from optical measurement to their match from contact measurements is determined and applied to the whole point cloud. The efficiency of the proposed algorithm was evaluated by comparison with data from a coordinate measuring machine (CMM). Three surfaces were used for this evaluation: plane, turbine blade and engine cover. For the planar surface the achieved improvement was of around 200 μm. Similar results were obtained for the turbine blade but for the engine cover the improvement was smaller. For both freeform surfaces the improvement was higher for raw data than for data after creation of mesh of triangles.

  6. High energy density capacitors fabricated by thin film technology

    International Nuclear Information System (INIS)

    Barbee, T W; Johnson, G W; Wagner, A V.

    1999-01-01

    Low energy density in conventional capacitors severely limits efforts to miniaturize power electronics and imposes design limitations on electronics in general. We have successfully applied physical vapor deposition technology to greatly increase capacitor energy density. The high dielectric breakdown strength we have achieved in alumina thin films allows high energy density to be achieved with this moderately low dielectric constant material. The small temperature dependence of the dielectric constant, and the high reliability, high resistivity, and low dielectric loss of Al 2 O 3 , make it even more appealing. We have constructed single dielectric layer thin film capacitors and shown that they can be stacked to form multilayered structures with no loss in yield for a given capacitance. Control of film growth morphology is critical for achieving the smooth, high quality interfaces between metal and dielectric necessary for device operation at high electric fields. Most importantly, high rate deposition with extremely low particle generation is essential for achieving high energy storage at a reasonable cost. This has been achieved by reactive magnetron sputtering in which the reaction to form the dielectric oxide has been confined to the deposition surface. By this technique we have achieved a yield of over 50% for 1 cm 2 devices with an energy density of 14 J per cubic centimeter of Al 2 O 3 dielectric material in 1.2 kV, 4 nF devices. By further reducing defect density and increasing the dielectric constant of the material, we will be able to increase capacitance and construct high energy density devices to meet the requirements of applications in power electronics

  7. HIGH DENSITY QCD WITH HEAVY-IONS

    CERN Multimedia

    The Addendum 1 to Volume 2 of the CMS Physics TDR has been published The Heavy-Ion analysis group completed the writing of a TDR summarizing the CMS plans in using heavy ion collisions to study high density QCD. The document was submitted to the LHCC in March and presented in the Open Session of the LHCC on May 9th. The study of heavy-ion physics at the LHC is promising to be very exciting. LHC will open a new energy frontier in ultra-relativistic heavy-ion physics. The collision energy of heavy nuclei at sNN = 5.5 TeV will be thirty times larger than what is presently available at RHIC. We will certainly probe quark and gluon matter at unprecedented values of energy density. The prime goal of this research programme is to study the fundamental theory of the strong interaction - Quantum Chromodynamics (QCD) - in extreme conditions of temperature, density and parton momentum fraction (low-x). Such studies, with impressive experimental and theoretical advances in recent years thanks to the wealth of high-qua...

  8. Distanced Data: Transcribing Other People's Research Tapes

    Science.gov (United States)

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  9. Localized leak detection utilizing moisture sensitive tape

    International Nuclear Information System (INIS)

    Riddle, P.

    1984-01-01

    Moisture sensitive tape (MST) has been used in various nuclear power plants to detect leaks in reactor piping systems. The sensor assembly consists of MST, transponder, and sensor carrier, and is installed on the exterior of thermal insulation. The components, applications, installation, and purchasing information are discussed in the paper

  10. Conventional Tape versus Kinesiotape for Hallux Valgus Correction

    Directory of Open Access Journals (Sweden)

    Nadia Lotfy Radwan

    2017-01-01

    Full Text Available This study was commenced to compare the effect of Kinesiotape (KT versus conventional tape (CT on HVA and IMA as well as the intensity of pain from HV deformity. Methodology: Female patients with age 45 to 60 years and diagnosed with mild to moderate HV were included in the study. The foot pain intensity was assessed by visual analogue scale (VAS before applying tape and after completion of the study. Results: The outcome measures of pain intensity showed a non-significant difference between both groups before intervention (p>0.05. Within both KT and CT groups, the pre-and post-treatment scores were significantly different (p˂0.05. In the comparison of the post treatment scores, there was a significant difference (p˂0.05 between both groups favouring the KT group..

  11. An x-ray backlit Talbot-Lau deflectometer for high-energy-density electron density diagnostics

    Science.gov (United States)

    Valdivia, M. P.; Stutman, D.; Stoeckl, C.; Theobald, W.; Mileham, C.; Begishev, I. A.; Bromage, J.; Regan, S. P.

    2016-02-01

    X-ray phase-contrast techniques can measure electron density gradients in high-energy-density plasmas through refraction induced phase shifts. An 8 keV Talbot-Lau interferometer consisting of free standing ultrathin gratings was deployed at an ultra-short, high-intensity laser system using K-shell emission from a 1-30 J, 8 ps laser pulse focused on thin Cu foil targets. Grating survival was demonstrated for 30 J, 8 ps laser pulses. The first x-ray deflectometry images obtained under laser backlighting showed up to 25% image contrast and thus enabled detection of electron areal density gradients with a maximum value of 8.1 ± 0.5 × 1023 cm-3 in a low-Z millimeter sized sample. An electron density profile was obtained from refraction measurements with an error of x-ray source-size, similar to conventional radiography.

  12. Chapter 7: High-Density H-Mode Operation in ASDEX Upgrade

    International Nuclear Information System (INIS)

    Stober, Joerg Karl; Lang, Peter Thomas; Mertens, Vitus

    2003-01-01

    Recent results are reported on the maximum achievable H-mode density and the behavior of pedestal density and central density peaking as this limit is approached. The maximum achievable H-mode density roughly scales as the Greenwald density, though a dependence on B t is clearly observed. In contrast to the stiff temperature profiles, the density profiles seem to allow more shape variation and especially with high-field-side pellet-injection, strongly peaked profiles with good confinement have been achieved. Also, spontaneous density peaking at high densities is observed in ASDEX Upgrade, which is related to the generally observed large time constants for the density profile equilibration. The equilibrated density profile shapes depend strongly on the heat-flux profile in the sense that central heating leads to significantly flatter profiles

  13. Over 15 MA/cm2 of critical current density in 4.8 µm thick, Zr-doped (Gd,Y)Ba2Cu3Ox superconductor at 30 K, 3T.

    Science.gov (United States)

    Majkic, Goran; Pratap, Rudra; Xu, Aixia; Galstyan, Eduard; Selvamanickam, Venkat

    2018-05-03

    An Advanced MOCVD (A-MOCVD) reactor was used to deposit 4.8 µm thick (Gd,Y)BaCuO tapes with 15 mol% Zr addition in a single pass. A record-high critical current density (J c ) of 15.11 MA/cm 2 has been measured over a bridge at 30 K, 3T, corresponding to an equivalent (I c ) value of 8705 A/12 mm width. This corresponds to a lift factor in critical current of ~11 which is the highest ever reported to the best of author's knowledge. The measured critical current densities at 3T (B||c) and 30, 40 and 50 K, respectively, are 15.11, 9.70 and 6.26 MA/cm 2 , corresponding to equivalent Ic values of 8705, 5586 and 3606 A/12 mm and engineering current densities (J e ) of 7068, 4535 and 2928 A/mm 2 . The engineering current density (J e ) at 40 K, 3T is 7 times higher than that of the commercial HTS tapes available with 7.5 mol% Zr addition. Such record-high performance in thick films (>1 µm) is a clear demonstration that growing thick REBCO films with high critical current density (J c ) is possible, contrary to the usual findings of strong J c degradation with film thickness. This achievement was possible due to a combination of strong temperature control and uniform laminar flow achieved in the A-MOCVD system, coupled with optimization of BaZrO 3 nanorod growth parameters.

  14. Effect of crystallization rate of initial alloy on magnetic properties of amorphous tape

    International Nuclear Information System (INIS)

    Roshchin, V.E.; Gribanov, V.P.; Shcherbakov, D.G.; Gun'kin, V.E.

    1994-01-01

    An investigation is made into mechanism and character of cooling rate effect when castings crytallizing on magnetic properties of rapidly quenched amorphous tape of Fe 78 B 12 Si 9 Ni 1 alloy. The increase of cooling rate and holding at heat for superheated melt is shown to result in a rise of Curie point of amorphous tape

  15. Effects of two different knee tape procedures on lower-limb kinematics and kinetics in recreational runners.

    Science.gov (United States)

    Howe, A; Campbell, A; Ng, L; Hall, T; Hopper, D

    2015-08-01

    The purpose of this study was to compare the effects of Mulligan's tape (MT) and kinesio tape (KT) with no tape (NT) on hip and knee kinematics and kinetics during running. Twenty-nine female recreational runners performed a series of 'run-throughs' along a 10-m runway under the three taping conditions. Two force plates and a 14-camera Vicon motion analysis system (Oxford Metrics, Inc., Oxford, UK) captured kinematic and kinetic data for each dependent variable from ground contact to toe off. Comparisons of each dependent variable under three taping conditions were assessed through Statistical Package for the Social Sciences (SPSS; SPSS, Inc., Chicago, Illinois, USA; P-value kinetics, between KT and NT (P = 1.000). MT appears to influence hip and knee biomechanics during running in an asymptomatic sample, whereas KT appeared to be biomechanically not different from NT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Experimental study of high density foods for the Space Operations Center

    Science.gov (United States)

    Ahmed, S. M.

    1981-01-01

    The experimental study of high density foods for the Space Operations Center is described. A sensory evaluation of the high density foods was conducted first to test the acceptability of the products. A shelf-life study of the high density foods was also conducted for three different time lengths at three different temperatures. The nutritional analysis of the high density foods is at present incomplete.

  17. Fluorescent Fe K Emission from High Density Accretion Disks

    Science.gov (United States)

    Bautista, Manuel; Mendoza, Claudio; Garcia, Javier; Kallman, Timothy R.; Palmeri, Patrick; Deprince, Jerome; Quinet, Pascal

    2018-06-01

    Iron K-shell lines emitted by gas closely orbiting black holes are observed to be grossly broadened and skewed by Doppler effects and gravitational redshift. Accordingly, models for line profiles are widely used to measure the spin (i.e., the angular momentum) of astrophysical black holes. The accuracy of these spin estimates is called into question because fitting the data requires very high iron abundances, several times the solar value. Meanwhile, no plausible physical explanation has been proffered for why these black hole systems should be so iron rich. The most likely explanation for the super-solar iron abundances is a deficiency in the models, and the leading candidate cause is that current models are inapplicable at densities above 1018 cm-3. We study the effects of high densities on the atomic parameters and on the spectral models for iron ions. At high densities, Debye plasma can affect the effective atomic potential of the ions, leading to observable changes in energy levels and atomic rates with respect to the low density case. High densities also have the effec of lowering energy the atomic continuum and reducing the recombination rate coefficients. On the spectral modeling side, high densities drive level populations toward a Boltzman distribution and very large numbers of excited atomic levels, typically accounted for in theoretical spectral models, may contribute to the K-shell spectrum.

  18. Phenomenology of high density disruptions in the TFTR tokamak

    International Nuclear Information System (INIS)

    Fredrickson, E.D.; McGuire, K.M.; Bell, M.G.

    1993-01-01

    Studies of high density disruptions on TFTR, including a comparison of minor and major disruptions at high density, provide important new information regarding the nature of the disruption mechanism. Further, for the first time, an (m,n)=(1,1) 'cold bubble' precursor to high density disruptions has been experimentally observed in the electron temperature profile. The precursor to major disruptions resembles the 'vacuum bubble' model of disruptions first proposed by B.B. Kadomtsev and O.P. Pogutse (Sov. Phys. - JETP 38 (1974) 283). (author). Letter-to-the-editor. 25 refs, 3 figs

  19. High Energy Density Polymer Film Capacitors

    National Research Council Canada - National Science Library

    Boufelfel, Ali

    2006-01-01

    High-energy-density capacitors that are compact and light-weight are extremely valuable in a number of critical DoD systems that include portable field equipment, pulsed lasers, detection equipment...

  20. Peculiarities on voltage - current characteristics of HTS tapes at overloading conditions cooled by liquid nitrogen

    International Nuclear Information System (INIS)

    Vysotsky, V S; Fetisov, S S; Sytnikov, V E

    2008-01-01

    Electro - technical devices are considered as the most prospective use for high temperature superconductors. For such devices the overload currents due to faults in grids are the operational reality. In these cases the fault currents may forcibly go to superconductors being sometimes dozens times more than the critical currents of HTS. Overloads are the working modes for fault current limiters also. To understand the behavior of HTS devices at overloads it is important to study voltage-current characteristics (VCC) of basic HTS tapes in real cooling conditions. The knowledge of VCC permits to model and to simulate properly HTS devices behavior at overloads. We performed the study of VCC of several HTS tapes at currents several times more than their critical ones. Both, 1-G and 2-G tapes were tested. There were found peculiarities or 'spikes' on VCC at rising currents that vanished at decaying currents. It was shown that such peculiarities are determined by the change of cooling conditions from the convective heat exchange to the nucleate boiling. Nucleate boiling activation and development times were determined. Their dependencies on heat release were measured. The data obtained can be used in simulation of heating of real superconducting devices at overload conditions