WorldWideScience

Sample records for high contrast object

  1. An eigenfunction method for reconstruction of large-scale and high-contrast objects.

    Science.gov (United States)

    Waag, Robert C; Lin, Feng; Varslot, Trond K; Astheimer, Jeffrey P

    2007-07-01

    A multiple-frequency inverse scattering method that uses eigenfunctions of a scattering operator is extended to image large-scale and high-contrast objects. The extension uses an estimate of the scattering object to form the difference between the scattering by the object and the scattering by the estimate of the object. The scattering potential defined by this difference is expanded in a basis of products of acoustic fields. These fields are defined by eigenfunctions of the scattering operator associated with the estimate. In the case of scattering objects for which the estimate is radial, symmetries in the expressions used to reconstruct the scattering potential greatly reduce the amount of computation. The range of parameters over which the reconstruction method works well is illustrated using calculated scattering by different objects. The method is applied to experimental data from a 48-mm diameter scattering object with tissue-like properties. The image reconstructed from measurements has, relative to a conventional B-scan formed using a low f-number at the same center frequency, significantly higher resolution and less speckle, implying that small, high-contrast structures can be demonstrated clearly using the extended method.

  2. High-resolution observation of phase contrast at 1MeV. Amorphous or crystalline objects

    International Nuclear Information System (INIS)

    Bourret, A.; Desseaux, J.

    1975-01-01

    Many authors have stressed the possibilities of high voltage to improve resolution, but owing to numerous experimental difficulties the resolution limit at 1MeV, which lies around 1A for conventional lenses, has so far been unattainable. Thus the phase contrast at 1MeV has not been studied on evaporated objects. On the other hand the fringes of crystal planes have been observed at 1MeV. the CEN-G microscope having been considerably modified it has been possible to observe the phase contrast of amorphous or crystalline objects [fr

  3. Visibility of minute objects with low contrast

    International Nuclear Information System (INIS)

    Sato, Nobuo

    1982-01-01

    Minimum perceptible contrast was obtained with a penetrameter made of aluminum plates, in which 40 very small holes were perforated. An object can be seen when its contrast exceeds the minimum perceptible contrast. Visual threshold contrast ratio offers minimum perceptible diameter (MPD) which is theoretically obtained from an image contrast corresponding to the technique applied. The MPDs were obtained prior to experiment as a function of system speed, beam quality, exposure range and magnification, which resulted in a reasonable agreement with the experimental results. The visibility of small dot-like objects depends on the granularity as its threshold is governed by the surrounding grainy noise. However it was revealed that MTF was as important as granularity. Dot and lineshaped objects were simulated with small glass beads and nylon fibrils, respectively, in order to make ROC analysis on the different radiographic techniques with a CGR Senograph 500T mammographic unit. The 1.5X magnification technique showed the largest advantage on phantom work basis, but clinical evaluation showed the different weight of the affecting physical factors. The results of ROC analysis were extended to entropy analysis. The visibility in actual mammography depends upon the acutance of images as Xeroradiography proved. (Kako, I.)

  4. Positron emission mammography (PEM): Effect of activity concentration, object size, and object contrast on phantom lesion detection

    International Nuclear Information System (INIS)

    MacDonald, Lawrence R.; Wang, Carolyn L.; Eissa, Marna; Haseley, David; Kelly, Mary M.; Liu, Franklin; Parikh, Jay R.; Beatty, J. David; Rogers, James V.

    2012-01-01

    Purpose: To characterize the relationship between lesion detection sensitivity and injected activity as a function of lesion size and contrast on the PEM (positron emission mammography) Flex Solo II scanner using phantom experiments. Methods: Phantom lesions (spheres 4, 8, 12, 16, and 20 mm diameter) were randomly located in uniform background. Sphere activity concentrations were 3 to 21 times the background activity concentration (BGc). BGc was a surrogate for injected activity; BGc ranged from 0.44–4.1 kBq/mL, corresponding to 46–400 MBq injections. Seven radiologists read 108 images containing zero, one, or two spheres. Readers used a 5-point confidence scale to score the presence of spheres. Results: Sensitivity was 100% for lesions ≥12 mm under all conditions except for one 12 mm sphere with the lowest contrast and lowest BGc (60% sensitivity). Sensitivity was 100% for 8 mm spheres when either contrast or BGc was high, and 100% for 4 mm spheres only when both contrast and BGc were highest. Sphere contrast recovery coefficients (CRC) were 49%, 34%, 26%, 14%, and 2.8% for the largest to smallest spheres. Cumulative specificity was 98%. Conclusions: Phantom lesion detection sensitivity depends more on sphere size and contrast than on BGc. Detection sensitivity remained ≥90% for injected activities as low as 100 MBq, for lesions ≥8 mm. Low CRC in 4 mm objects results in moderate detection sensitivity even for 400 MBq injected activity, making it impractical to optimize injected activity for such lesions. Low CRC indicates that when lesions <8 mm are observed on PEM images they are highly tracer avid with greater potential of clinical significance. High specificity (98%) suggests that image statistical noise does not lead to false positive findings. These results apply to the 85 mm thick object used to obtain them; lesion detectability should be better (worse) for thinner (thicker) objects based on the reduced (increased) influence of photon attenuation.

  5. Daylight illumination-color-contrast tables for full-form objects naturally illuminated objects

    CERN Document Server

    Nagel, M

    1978-01-01

    Daylight Illumination-Color-Contrast Tables for Full-form Objects is the result of a major computational project concerning the illumination, color, and contrast conditions in naturally illuminated objects. The project from which this two-chapter book is derived is originally conceived in support of the various remote sensing and image processing activities of the Deutsche Forschungs- und Versuchsanstalt für Luft- und Raumfahrt, Oberpfaffenhofen, West Germany DFVLR, in particular, those depending on the quantitative photometric and colorimetric evaluation of photographs and other environmental

  6. Monte Carlo dosimetry of iodine contrast objects in a small animal microCT

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Villafuerte, M., E-mail: mercedes@fisica.unam.mx [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico); Martinez-Davalos, A. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico)

    2011-08-21

    Small animal microcomputed tomography (microCT) studies with iodine-based contrast media are commonly used in preclinical research. While the use of contrast media improves the quality of the images, it can also result in an increase in the absorbed dose to organs with high concentration of the contrast agent, which might cause radiation damage to the animal. In this work we present the results of a Monte Carlo investigation of a microCT dosimetry study using mouse-sized cylindrical water phantoms with iodine contrast insets for different X-ray spectra (Mo and W targets, 30-80 kVp), iodine concentrations (0, 5, 10 and 15 mg mL{sup -1}) and contrast object sizes (3 and 10 mm diameter). Our results indicate an absorbed dose increase in the contrast-inset regions with respect to the absorbed dose distribution within a reference uniform water phantom. The calculated spatial absorbed dose distributions show large gradients due to beam hardening effects, and large absorbed dose enhancement as the mean energy of the beam and iodine concentration increase. We have found that absorbed doses in iodine contrast objects can increase by a factor of up to 12 for a realistic 80 kVp X-ray spectra and an iodine concentration of 15 mg mL{sup -1}.

  7. Computed radiography utilizing laser-stimulated luminescence: detectability of simulated low-contrast radiographic objects.

    Science.gov (United States)

    Higashida, Y; Moribe, N; Hirata, Y; Morita, K; Doudanuki, S; Sonoda, Y; Katsuda, N; Hiai, Y; Misumi, W; Matsumoto, M

    1988-01-01

    Threshold contrasts of low-contrast objects with computed radiography (CR) images were compared with those of blue and green emitting screen-film systems by employing the 18-alternative forced choice (18-AFC) procedure. The dependence of the threshold contrast on the incident X-ray exposure and also the object size was studied. The results indicated that the threshold contrasts of CR system were comparable to those of blue and green screen-film systems and decreased with increasing object size, and increased with decreasing incident X-ray exposure. The increase in threshold contrasts was small when the relative incident exposure decreased from 1 to 1/4, and was large when incident exposure was decreased further.

  8. Reduced-Contrast Approximations for High-Contrast Multiscale Flow Problems

    KAUST Repository

    Chung, Eric T.; Efendiev, Yalchin

    2010-01-01

    In this paper, we study multiscale methods for high-contrast elliptic problems where the media properties change dramatically. The disparity in the media properties (also referred to as high contrast in the paper) introduces an additional scale that needs to be resolved in multiscale simulations. First, we present a construction that uses an integral equation to represent the highcontrast component of the solution. This representation involves solving an integral equation along the interface where the coefficients are discontinuous. The integral representation suggests some multiscale approaches that are discussed in the paper. One of these approaches entails the use of interface functions in addition to multiscale basis functions representing the heterogeneities without high contrast. In this paper, we propose an approximation for the solution of the integral equation using the interface problems in reduced-contrast media. Reduced-contrast media are obtained by lowering the variance of the coefficients. We also propose a similar approach for the solution of the elliptic equation without using an integral representation. This approach is simpler to use in the computations because it does not involve setting up integral equations. The main idea of this approach is to approximate the solution of the high-contrast problem by the solutions of the problems formulated in reduced-contrast media. In this approach, a rapidly converging sequence is proposed where only problems with lower contrast are solved. It was shown that this sequence possesses the convergence rate that is inversely proportional to the reduced contrast. This approximation allows choosing the reduced-contrast problem based on the coarse-mesh size as discussed in this paper. We present a simple application of this approach to homogenization of elliptic equations with high-contrast coefficients. The presented approaches are limited to the cases where there are sharp changes in the contrast (i.e., the high

  9. Graphical user interface to optimize image contrast parameters used in object segmentation - biomed 2009.

    Science.gov (United States)

    Anderson, Jeffrey R; Barrett, Steven F

    2009-01-01

    Image segmentation is the process of isolating distinct objects within an image. Computer algorithms have been developed to aid in the process of object segmentation, but a completely autonomous segmentation algorithm has yet to be developed [1]. This is because computers do not have the capability to understand images and recognize complex objects within the image. However, computer segmentation methods [2], requiring user input, have been developed to quickly segment objects in serial sectioned images, such as magnetic resonance images (MRI) and confocal laser scanning microscope (CLSM) images. In these cases, the segmentation process becomes a powerful tool in visualizing the 3D nature of an object. The user input is an important part of improving the performance of many segmentation methods. A double threshold segmentation method has been investigated [3] to separate objects in gray scaled images, where the gray level of the object is among the gray levels of the background. In order to best determine the threshold values for this segmentation method the image must be manipulated for optimal contrast. The same is true of other segmentation and edge detection methods as well. Typically, the better the image contrast, the better the segmentation results. This paper describes a graphical user interface (GUI) that allows the user to easily change image contrast parameters that will optimize the performance of subsequent object segmentation. This approach makes use of the fact that the human brain is extremely effective in object recognition and understanding. The GUI provides the user with the ability to define the gray scale range of the object of interest. These lower and upper bounds of this range are used in a histogram stretching process to improve image contrast. Also, the user can interactively modify the gamma correction factor that provides a non-linear distribution of gray scale values, while observing the corresponding changes to the image. This

  10. Height measurement of transparent objects by adopting differential interference contrast technology

    International Nuclear Information System (INIS)

    Yu, Sheng-Kang; Liu, Ting-Kun; Lin, Shih-Chieh

    2010-01-01

    In this study, the differential interference contrast (DIC) approach originally used for image enhancement to increase the contrast between a transparent object and the background is adopted for the dimension measurement of transparent structures. With the phase difference image retrieved using the DIC technique, the phase map of the examined object can be approximated by integrating the phase difference. The need of integration accuracy is much higher for measurement than for image enhancement. In this study, a modified Fourier phase integration is proposed to reduce the effects of noise on surface profile reconstruction. The simulation results show that the proposed approach can effectively reduce the effects of noise. Experimental results are also conducted to study the feasibility of using the transmitted DIC with the proposed integration method for transparent object measurement. The results show that the height of a transparent structure measured using the DIC method is quite close to those measured using an atomic force microscope, while those measured using the white-light interference method result in a much larger measurement than all others.

  11. High-energy x-ray grating-based phase-contrast radiography of human anatomy

    Science.gov (United States)

    Horn, Florian; Hauke, Christian; Lachner, Sebastian; Ludwig, Veronika; Pelzer, Georg; Rieger, Jens; Schuster, Max; Seifert, Maria; Wandner, Johannes; Wolf, Andreas; Michel, Thilo; Anton, Gisela

    2016-03-01

    X-ray grating-based phase-contrast Talbot-Lau interferometry is a promising imaging technology that has the potential to raise soft tissue contrast in comparison to conventional attenuation-based imaging. Additionally, it is sensitive to attenuation, refraction and scattering of the radiation and thus provides complementary and otherwise inaccessible information due to the dark-field image, which shows the sub-pixel size granularity of the measured object. Until recent progress the method has been mainly limited to photon energies below 40 keV. Scaling the method to photon energies that are sufficient to pass large and spacious objects represents a challenging task. This is caused by increasing demands regarding the fabrication process of the gratings and the broad spectra that come along with the use of polychromatic X-ray sources operated at high acceleration voltages. We designed a setup that is capable to reach high visibilities in the range from 50 to 120 kV. Therefore, spacious and dense parts of the human body with high attenuation can be measured, such as a human knee. The authors will show investigations on the resulting attenuation, differential phase-contrast and dark-field images. The images experimentally show that X-ray grating-based phase-contrast radiography is feasible with highly absorbing parts of the human body containing massive bones.

  12. Characterization of a high-energy in-line phase contrast tomosynthesis prototype.

    Science.gov (United States)

    Wu, Di; Yan, Aimin; Li, Yuhua; Wong, Molly D; Zheng, Bin; Wu, Xizeng; Liu, Hong

    2015-05-01

    In this research, a high-energy in-line phase contrast tomosynthesis prototype was developed and characterized through quantitative investigations and phantom studies. The prototype system consists of an x-ray source, a motorized rotation stage, and a CMOS detector with a pixel pitch of 0.05 mm. The x-ray source was operated at 120 kVp for this study, and the objects were mounted on the rotation stage 76.2 cm (R1) from the source and 114.3 cm (R2) from the detector. The large air gap between the object and detector guarantees sufficient phase-shift effects. The quantitative evaluation of this prototype included modulation transfer function and noise power spectrum measurements conducted under both projection mode and tomosynthesis mode. Phantom studies were performed including three custom designed phantoms with complex structures: a five-layer bubble wrap phantom, a fishbone phantom, and a chicken breast phantom with embedded fibrils and mass structures extracted from an ACR phantom. In-plane images of the phantoms were acquired to investigate their image qualities through observation, intensity profile plots, edge enhancement evaluations, and/or contrast-to-noise ratio calculations. In addition, the robust phase-attenuation duality (PAD)-based phase retrieval method was applied to tomosynthesis for the first time in this research. It was utilized as a preprocessing method to fully exhibit phase contrast on the angular projection before reconstruction. The resolution and noise characteristics of this high-energy in-line phase contrast tomosynthesis prototype were successfully investigated and demonstrated. The phantom studies demonstrated that this imaging prototype can successfully remove the structure overlapping in phantom projections, obtain delineate interfaces, and achieve better contrast-to-noise ratio after applying phase retrieval to the angular projections. This research successfully demonstrated a high-energy in-line phase contrast tomosynthesis

  13. High Contrast Vacuum Nuller Testbed (VNT) Contrast, Performance and Null Control

    Science.gov (United States)

    Lyon, Richard G.; Clampin, Mark; Petrone, Peter; Mallik, Udayan; Madison, Timothy; Bolcar, Matthew R.

    2012-01-01

    Herein we report on our Visible Nulling Coronagraph high-contrast result of 109 contrast averaged over a focal planeregion extending from 14 D with the Vacuum Nuller Testbed (VNT) in a vibration isolated vacuum chamber. TheVNC is a hybrid interferometriccoronagraphic approach for exoplanet science. It operates with high Lyot stopefficiency for filled, segmented and sparse or diluted-aperture telescopes, thereby spanning the range of potential futureNASA flight telescopes. NASAGoddard Space Flight Center (GSFC) has a well-established effort to develop the VNCand its technologies, and has developed an incremental sequence of VNC testbeds to advance this approach and itsenabling technologies. These testbeds have enabled advancement of high-contrast, visible light, nulling interferometry tounprecedented levels. The VNC is based on a modified Mach-Zehnder nulling interferometer, with a W configurationto accommodate a hex-packed MEMS based deformable mirror, a coherent fiber bundle and achromatic phase shifters.We give an overview of the VNT and discuss the high-contrast laboratory results, the optical configuration, criticaltechnologies and null sensing and control.

  14. High contrast vacuum nuller testbed (VNT) contrast, performance, and null control

    Science.gov (United States)

    Lyon, Richard G.; Clampin, Mark; Petrone, Peter; Mallik, Udayan; Madison, Timothy; Bolcar, Matthew R.

    2012-09-01

    Herein we report on our Visible Nulling Coronagraph high-contrast result of 109 contrast averaged over a focal plane region extending from 1 - 4 λ/D with the Vacuum Nuller Testbed (VNT) in a vibration isolated vacuum chamber. The VNC is a hybrid interferometric/coronagraphic approach for exoplanet science. It operates with high Lyot stop efficiency for filled, segmented and sparse or diluted-aperture telescopes, thereby spanning the range of potential future NASA flight telescopes. NASA/Goddard Space Flight Center (GSFC) has a well-established effort to develop the VNC and its technologies, and has developed an incremental sequence of VNC testbeds to advance this approach and its enabling technologies. These testbeds have enabled advancement of high-contrast, visible light, nulling interferometry to unprecedented levels. The VNC is based on a modified Mach-Zehnder nulling interferometer, with a “W” configuration to accommodate a hex-packed MEMS based deformable mirror, a coherent fiber bundle and achromatic phase shifters. We give an overview of the VNT and discuss the high-contrast laboratory results, the optical configuration, critical technologies and null sensing and control.

  15. Application of polarization in high speed, high contrast inspection

    Science.gov (United States)

    Novak, Matthew J.

    2017-08-01

    Industrial optical inspection often requires high speed and high throughput of materials. Engineers use a variety of techniques to handle these inspection needs. Some examples include line scan cameras, high speed multi-spectral and laser-based systems. High-volume manufacturing presents different challenges for inspection engineers. For example, manufacturers produce some components in quantities of millions per month, per week or even per day. Quality control of so many parts requires creativity to achieve the measurement needs. At times, traditional vision systems lack the contrast to provide the data required. In this paper, we show how dynamic polarization imaging captures high contrast images. These images are useful for engineers to perform inspection tasks in some cases where optical contrast is low. We will cover basic theory of polarization. We show how to exploit polarization as a contrast enhancement technique. We also show results of modeling for a polarization inspection application. Specifically, we explore polarization techniques for inspection of adhesives on glass.

  16. High-throughput, high-resolution X-ray phase contrast tomographic microscopy for visualisation of soft tissue

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, S A; Marone, F; Hintermueller, C; Stampanoni, M [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Bensadoun, J-C; Aebischer, P, E-mail: samuel.mcdonald@psi.c [EPFL, School of Life Sciences, Station 15, 1015 Lausanne (Switzerland)

    2009-09-01

    The use of conventional absorption based X-ray microtomography can become limited for samples showing only very weak absorption contrast. However, a wide range of samples studied in biology and materials science can produce significant phase shifts of the X-ray beam, and thus the use of the phase signal can provide substantially increased contrast and therefore new and otherwise inaccessible information. The application of two approaches for high-throughput, high-resolution X-ray phase contrast tomography, both available on the TOMCAT beamline of the SLS, is illustrated. Differential Phase Contrast (DPC) imaging uses a grating interferometer and a phase-stepping technique. It has been integrated into the beamline environment on TOMCAT in terms of the fast acquisition and reconstruction of data and the availability to scan samples within an aqueous environment. The second phase contrast approach is a modified transfer of intensity approach that can yield the 3D distribution of the phase (refractive index) of a weakly absorbing object from a single tomographic dataset. These methods are being used for the evaluation of cell integrity in 3D, with the specific aim of following and analyzing progressive cell degeneration to increase knowledge of the mechanistic events of neurodegenerative disorders such as Parkinson's disease.

  17. Asymptotic expansions for high-contrast elliptic equations

    KAUST Repository

    Calo, Victor M.; Efendiev, Yalchin R.; Galvis, Juan

    2014-01-01

    In this paper, we present a high-order expansion for elliptic equations in high-contrast media. The background conductivity is taken to be one and we assume the medium contains high (or low) conductivity inclusions. We derive an asymptotic expansion with respect to the contrast and provide a procedure to compute the terms in the expansion. The computation of the expansion does not depend on the contrast which is important for simulations. The latter allows avoiding increased mesh resolution around high conductivity features. This work is partly motivated by our earlier work in [Domain decomposition preconditioners for multiscale flows in high-contrast media, Multiscale Model Simul. 8 (2010) 1461-1483] where we design efficient numerical procedures for solving high-contrast problems. These multiscale approaches require local solutions and our proposed high-order expansion can be used to approximate these local solutions inexpensively. In the case of a large-number of inclusions, the proposed analysis can help to design localization techniques for computing the terms in the expansion. In the paper, we present a rigorous analysis of the proposed high-order expansion and estimate the remainder of it. We consider both high-and low-conductivity inclusions. © 2014 World Scientific Publishing Company.

  18. Asymptotic expansions for high-contrast elliptic equations

    KAUST Repository

    Calo, Victor M.

    2014-03-01

    In this paper, we present a high-order expansion for elliptic equations in high-contrast media. The background conductivity is taken to be one and we assume the medium contains high (or low) conductivity inclusions. We derive an asymptotic expansion with respect to the contrast and provide a procedure to compute the terms in the expansion. The computation of the expansion does not depend on the contrast which is important for simulations. The latter allows avoiding increased mesh resolution around high conductivity features. This work is partly motivated by our earlier work in [Domain decomposition preconditioners for multiscale flows in high-contrast media, Multiscale Model Simul. 8 (2010) 1461-1483] where we design efficient numerical procedures for solving high-contrast problems. These multiscale approaches require local solutions and our proposed high-order expansion can be used to approximate these local solutions inexpensively. In the case of a large-number of inclusions, the proposed analysis can help to design localization techniques for computing the terms in the expansion. In the paper, we present a rigorous analysis of the proposed high-order expansion and estimate the remainder of it. We consider both high-and low-conductivity inclusions. © 2014 World Scientific Publishing Company.

  19. First application of liquid-metal-jet sources for small-animal imaging: High-resolution CT and phase-contrast tumor demarcation

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, Daniel H.; Lundstroem, Ulf; Burvall, Anna; Hertz, Hans M. [Department of Applied Physics, KTH Royal Institute of Technology/Albanova, 10691 Stockholm (Sweden); Westermark, Ulrica K.; Arsenian Henriksson, Marie [Department of Microbiology, Tumor and Cell Biology (MTC), Karolinska Institutet, 17177 Stockholm (Sweden)

    2013-02-15

    Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with {approx}7 {mu}m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 {mu}m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.

  20. Influence of sinogram affirmed iterative reconstruction of CT data on image noise characteristics and low-contrast detectability: an objective approach.

    Directory of Open Access Journals (Sweden)

    Christian von Falck

    Full Text Available OBJECTIVES: To utilize a novel objective approach combining a software phantom and an image quality metric to systematically evaluate the influence of sinogram affirmed iterative reconstruction (SAFIRE of multidetector computed tomography (MDCT data on image noise characteristics and low-contrast detectability (LCD. MATERIALS AND METHODS: A low-contrast and a high-contrast phantom were examined on a 128-slice scanner at different dose levels. The datasets were reconstructed using filtered back projection (FBP and SAFIRE and virtual low-contrast lesions (-20HU were inserted. LCD was evaluated using the multiscale structural similarity index (MS-SIM*. Image noise texture and spatial resolution were objectively evaluated. RESULTS: The use of SAFIRE led to an improvement of LCD for all dose levels and lesions sizes. The relative improvement of LCD was inversely related to the dose level, declining from 208%(±37%, 259%(±30% and 309%(±35% at 25mAs to 106%(±6%, 119%(±9% and 123%(±8% at 200mAs for SAFIRE filter strengths of 1, 3 and 5 (p<0.05. SAFIRE reached at least the LCD of FBP at a relative dose of 50%. There was no statistically significant difference in spatial resolution. The use of SAFIRE led to coarser image noise granularity. CONCLUSION: A novel objective approach combining a software phantom and the MS-SSIM* image quality metric was used to analyze the detectability of virtual low-contrast lesions against the background of image noise as created using SAFIRE in comparison to filtered back-projection. We found, that image noise characteristics using SAFIRE at 50% dose were comparable to the use of FBP at 100% dose with respect to lesion detectability. The unfamiliar imaging appearance of iteratively reconstructed datasets may in part be explained by a different, coarser noise characteristic as demonstrated by a granulometric analysis.

  1. Advancing High Contrast Adaptive Optics

    Science.gov (United States)

    Ammons, M.; Poyneer, L.; GPI Team

    2014-09-01

    A long-standing challenge has been to directly image faint extrasolar planets adjacent to their host suns, which may be ~1-10 million times brighter than the planet. Several extreme AO systems designed for high-contrast observations have been tested at this point, including SPHERE, Magellan AO, PALM-3000, Project 1640, NICI, and the Gemini Planet Imager (GPI, Macintosh et al. 2014). The GPI is the world's most advanced high-contrast adaptive optics system on an 8-meter telescope for detecting and characterizing planets outside of our solar system. GPI will detect a previously unstudied population of young analogs to the giant planets of our solar system and help determine how planetary systems form. GPI employs a 44x44 woofer-tweeter adaptive optics system with a Shack-Hartmann wavefront sensor operating at 1 kHz. The controller uses Fourier-based reconstruction and modal gains optimized from system telemetry (Poyneer et al. 2005, 2007). GPI has an apodized Lyot coronal graph to suppress diffraction and a near-infrared integral field spectrograph for obtaining planetary spectra. This paper discusses current performance limitations and presents the necessary instrumental modifications and sensitivity calculations for scenarios related to high-contrast observations of non-sidereal targets.

  2. A BASIC program for an IBM PC compatible computer for drawing the weak phase object contrast transfer function

    International Nuclear Information System (INIS)

    Olsen, A.; Skjerpe, P.

    1989-01-01

    This report describes a computer program which is useful in high resolution microscopy. The program is written in EBASIC and calculates the weak phase object contrast transfer function as function of instrumental and imaging parameters. The function is plotted on the PC graphics screen, and by a Print Screen command the function can be copied to the printer. The program runs on both the Hercules graphic card and the IBM CGA card. 2 figs

  3. Homogenization of High-Contrast Brinkman Flows

    KAUST Repository

    Brown, Donald L.

    2015-04-16

    Modeling porous flow in complex media is a challenging problem. Not only is the problem inherently multiscale but, due to high contrast in permeability values, flow velocities may differ greatly throughout the medium. To avoid complicated interface conditions, the Brinkman model is often used for such flows [O. Iliev, R. Lazarov, and J. Willems, Multiscale Model. Simul., 9 (2011), pp. 1350--1372]. Instead of permeability variations and contrast being contained in the geometric media structure, this information is contained in a highly varying and high-contrast coefficient. In this work, we present two main contributions. First, we develop a novel homogenization procedure for the high-contrast Brinkman equations by constructing correctors and carefully estimating the residuals. Understanding the relationship between scales and contrast values is critical to obtaining useful estimates. Therefore, standard convergence-based homogenization techniques [G. A. Chechkin, A. L. Piatniski, and A. S. Shamev, Homogenization: Methods and Applications, Transl. Math. Monogr. 234, American Mathematical Society, Providence, RI, 2007, G. Allaire, SIAM J. Math. Anal., 23 (1992), pp. 1482--1518], although a powerful tool, are not applicable here. Our second point is that the Brinkman equations, in certain scaling regimes, are invariant under homogenization. Unlike in the case of Stokes-to-Darcy homogenization [D. Brown, P. Popov, and Y. Efendiev, GEM Int. J. Geomath., 2 (2011), pp. 281--305, E. Marusic-Paloka and A. Mikelic, Boll. Un. Mat. Ital. A (7), 10 (1996), pp. 661--671], the results presented here under certain velocity regimes yield a Brinkman-to-Brinkman upscaling that allows using a single software platform to compute on both microscales and macroscales. In this paper, we discuss the homogenized Brinkman equations. We derive auxiliary cell problems to build correctors and calculate effective coefficients for certain velocity regimes. Due to the boundary effects, we construct

  4. Looking at a contrast object before speaking boosts referential informativeness, but is not essential.

    Science.gov (United States)

    Davies, Catherine; Kreysa, Helene

    2017-07-01

    Variation in referential form has traditionally been accounted for by theoretical frameworks focusing on linguistic and discourse features. Despite the explosion of interest in eye tracking methods in psycholinguistics, the role of visual scanning behaviour in informative reference production is yet to be comprehensively investigated. Here we examine the relationship between speakers' fixations to relevant referents and the form of the referring expressions they produce. Overall, speakers were fully informative across simple and (to a lesser extent) more complex displays, providing appropriately modified referring expressions to enable their addressee to locate the target object. Analysis of contrast fixations revealed that looking at a contrast object boosts but is not essential for full informativeness. Contrast fixations which take place immediately before speaking provide the greatest boost. Informative referring expressions were also associated with later speech onsets than underinformative ones. Based on the finding that fixations during speech planning facilitate but do not fully predict informative referring, direct visual scanning is ruled out as a prerequisite for informativeness. Instead, pragmatic expectations of informativeness may play a more important role. Results are consistent with a goal-based link between eye movements and language processing, here applied for the first time to production processes. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. The highs and lows of object impossibility: effects of spatial frequency on holistic processing of impossible objects.

    Science.gov (United States)

    Freud, Erez; Avidan, Galia; Ganel, Tzvi

    2015-02-01

    Holistic processing, the decoding of a stimulus as a unified whole, is a basic characteristic of object perception. Recent research using Garner's speeded classification task has shown that this processing style is utilized even for impossible objects that contain an inherent spatial ambiguity. In particular, similar Garner interference effects were found for possible and impossible objects, indicating similar holistic processing styles for the two object categories. In the present study, we further investigated the perceptual mechanisms that mediate such holistic representation of impossible objects. We relied on the notion that, whereas information embedded in the high-spatial-frequency (HSF) content supports fine-detailed processing of object features, the information conveyed by low spatial frequencies (LSF) is more crucial for the emergence of a holistic shape representation. To test the effects of image frequency on the holistic processing of impossible objects, participants performed the Garner speeded classification task on images of possible and impossible cubes filtered for their LSF and HSF information. For images containing only LSF, similar interference effects were observed for possible and impossible objects, indicating that the two object categories were processed in a holistic manner. In contrast, for the HSF images, Garner interference was obtained only for possible, but not for impossible objects. Importantly, we provided evidence to show that this effect could not be attributed to a lack of sensitivity to object possibility in the LSF images. Particularly, even for full-spectrum images, Garner interference was still observed for both possible and impossible objects. Additionally, performance in an object classification task revealed high sensitivity to object possibility, even for LSF images. Taken together, these findings suggest that the visual system can tolerate the spatial ambiguity typical to impossible objects by relying on information

  6. Asymptotic expansions for high-contrast linear elasticity

    KAUST Repository

    Poveda, Leonardo A.; Huepo, Sebastian; Calo, Victor M.; Galvis, Juan

    2015-01-01

    We study linear elasticity problems with high contrast in the coefficients using asymptotic limits recently introduced. We derive an asymptotic expansion to solve heterogeneous elasticity problems in terms of the contrast in the coefficients. We study the convergence of the expansion in the H1 norm. © 2015 Elsevier B.V.

  7. Asymptotic expansions for high-contrast linear elasticity

    KAUST Repository

    Poveda, Leonardo A.

    2015-03-01

    We study linear elasticity problems with high contrast in the coefficients using asymptotic limits recently introduced. We derive an asymptotic expansion to solve heterogeneous elasticity problems in terms of the contrast in the coefficients. We study the convergence of the expansion in the H1 norm. © 2015 Elsevier B.V.

  8. Halftoning for high-contrast imaging

    Directory of Open Access Journals (Sweden)

    Kasper M.

    2011-07-01

    Full Text Available High-contrast instruments, such as SPHERE (upcoming planet finder instrument for the ESO-VLT, or EPICS (planet hunter project for the future E-ELT, will require customized components with spatially varying transmission (e.g. coronagraphs, optical components that reduce the contrast between a companion and its parent star. The goal of these sub-systems is to control the spatial transmission, either in a pupil plane (pupil apodization, or in a focal plane of the instrument (occulting mask, i.e. low-frequency filter. Reliably producing components with spatially varying transmission is not trivial, and different techniques have been already investigated for application to astronomy (e.g. metal deposition with spatially-varying thickness, or high-energy beam sensitive glass using e-beam lithography. We present some results related to the recent development of components with spatially varying transmission using a relatively simple technique analogous to the digital halftoning process used for printing applications.

  9. Phase contrast imaging: Effect of increased object-detector distances at X-ray diagnostic and megavoltage energies

    Energy Technology Data Exchange (ETDEWEB)

    Loveland, J.; Gundogdu, O. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom); Morton, E. [Rapiscan Systems, Units 2,3,4, Radnor Park Trading Estate, Congleton, Cheshire CW12 4XJ (United Kingdom); Wells, K. [CVSSP, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom); Bradley, D.A., E-mail: d.a.bradley@surrey.ac.uk [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2011-10-01

    The effect of varying object to detector separation at constant and varying magnification has been investigated at an accelerating potential of 30 kVp. Edge-contrast enhancement provided by phase effects was investigated for a drinking straw and found to provide up to 2.52{+-}0.02x the contrast for a PVC Heaviside step function. An optimum magnification of 1.5x was found to apply for the microfocus X-ray tube setup used. Imaging at nominal megavoltage energies was investigated using a Rapiscan Systems Eagle M4500 series scanner. For a fixed source-detector separation, increased magnification improved edge contrast and spatial resolution.

  10. Phase contrast imaging: Effect of increased object-detector distances at X-ray diagnostic and megavoltage energies

    International Nuclear Information System (INIS)

    Loveland, J.; Gundogdu, O.; Morton, E.; Wells, K.; Bradley, D.A.

    2011-01-01

    The effect of varying object to detector separation at constant and varying magnification has been investigated at an accelerating potential of 30 kVp. Edge-contrast enhancement provided by phase effects was investigated for a drinking straw and found to provide up to 2.52±0.02x the contrast for a PVC Heaviside step function. An optimum magnification of 1.5x was found to apply for the microfocus X-ray tube setup used. Imaging at nominal megavoltage energies was investigated using a Rapiscan Systems Eagle M4500 series scanner. For a fixed source-detector separation, increased magnification improved edge contrast and spatial resolution.

  11. Contrast nephropathy in high-risk patients undergoing coronary angiography and intervention

    International Nuclear Information System (INIS)

    Uddin, M.A.; Rabbani, M.A.; Jafary, F.H.; Bhatti, M.A.; Islam, M.

    2005-01-01

    Objective: To determine the incidence of contrast nephropathy in high-risk patients undergoing coronary angiography and percutaneous coronary intervention (PCI), and to define the characteristics of this cohort. Design: Descriptive study. Place and Duration of Study: The Aga Khan University Hospital, Karachi from January to December 2002. Patients and Methods: One hundred and fifteen patients with serum creatinine greater than 1.4mg/dl who underwent coronary angiography or PCI were included. All patients received non-ionic contrast dye. Acute contrast nephropathy was defined as rise in serum creatinine of >0.5mg/dl within 48 hours following the index procedure. Means and standard deviations were calculated for continuous variables and frequencies for categorical variables. Results: Mean age of patients was 62.3 year + 8.83. Mean pre-contrast creatinine was 1.9+0.9mg/dl. Eleven (9.65%) patients developed contrast nephropathy. 4.4% of patients with serum creatinine 4.0(p-value 0.001). 11.9% diabetic patients developed nephropathy compared to 6.3% of non-diabetics (p-value 0.355). 11.4% of hypertensive and 3.7% of non-hypertensive patients developed contrast-nephropathy (p-value 0.454). 12.9% of low dose group ( 100ml) developed nephropathy (p-value 0.188). Mean serum creatinine in low dose group was higher (3.0mg/dl vs. 1.7 mg/dl). Conclusion: The incidence of contrast nephropathy in this study was similar to that reported in literature. Risk of CIN was found to be significantly proportional to the severity of baseline renal disease. Trends towards higher risk of CIN were seen in patients with diabetes and hypertension. Higher incidence of CIN in patients receiving low-dose contrast was confounded by higher baseline serum creatinine in that group. (author)

  12. An objective method for High Dynamic Range source content selection

    DEFF Research Database (Denmark)

    Narwaria, Manish; Mantel, Claire; Da Silva, Matthieu Perreira

    2014-01-01

    With the aim of improving the immersive experience of the end user, High Dynamic Range (HDR) imaging has been gaining popularity. Therefore, proper validation and performance benchmarking of HDR processing algorithms is a key step towards standardization and commercial deployment. A crucial...... component of such validation studies is the selection of a challenging and balanced set of source (reference) HDR content. In order to facilitate this, we present an objective method based on the premise that a more challenging HDR scene encapsulates higher contrast, and as a result will show up more...

  13. Energy dependence of contrast-detail-dose and object-detectability-dose curves for CT scanners

    International Nuclear Information System (INIS)

    Wagner, L.K.; Cohen, G.

    1982-01-01

    The energy dependence of contrast-detail-dose (CdD) and object-detectability-dose (OdD) curves for computed tomographic scanners is investigated. The effects of changes in beam energy on perceptibility are shown to be due to changes in signal-to-noise ratio resulting from changes in contrast and photon statistics. Energy-dependence analysis of OdD curves is shown to depend on the atomic composition of the phantom used to generate the curves, while such an analysis of CdD curves is independent of the atomic composition of the phantom. It is also shown that any OdD curve can be generated from CdD curves and that use of this fact rectifies any potential energy-dependent interpretation of CdD curves

  14. 'J-KAREN' - high intensity, high contrast laser

    International Nuclear Information System (INIS)

    Kiriyama, Hiromitsu; Mori, Michiaki; Nakai, Yoshiki; Okada, Hajime; Sasao, Hajime; Sagisaka, Akito; Ochi, Yoshihiro; Tanaka, Momoko; Kondo, Kiminori; Tateno, Ryo; Sugiyama, Akira; Daido, Hiroyuki; Koike, Masato; Kawanishi, Syunichi; Shimomura, Takuya; Tanoue, Manabu; Wakai, Daisuke; Kondo, Shuji; Kanazawa, Shuhei

    2010-01-01

    We report on the high intensity, high contrast double chirped-pulse amplification (CPA) Ti:sapphire laser system (named J-KAREN). By use of an optical parametric chirped-pulse amplification (OPCPA) preamplifier that is seeded by a cleaned high-energy pulse, a background amplified spontaneous emission (ASE) level of 10 -10 relative to the peak main femtosecond pulse on the picosecond timescales demonstrated with an output energy of 1.7 J and a pulse duration of 30 fs, corresponding to a peak power of 60TW at a 10 Hz repetition rate. This system which uses a cryogenically-cooled Ti:sapphire final amplifier generates focused peak intensity in excess of 10 20 W/cm 2 at a 10 Hz repetition rate. (author)

  15. Factors that affect the level of detectability of objects of low contrast in diagnostic radiology

    International Nuclear Information System (INIS)

    Zuniga Vargas, F.

    2001-01-01

    The diagnosed imageneologia is every day more used by the medical staff to obtain diagnoses of diverse illnesses. In this branch, the conventional equipments of tubes of X Rays, equipments with fluoroscopic, angiographos, on-line tomographos, ultrasound equipment of magnetic resonance are used. All of them finally produce an image which will be used for the radiologist to evaluate the structures and pathology with in order to give to emit a good and precise diagnosis. From the total of radiation that the man receives annually, the medical irradiations are the main contributors after natural radiations. The applications of the ionized radiations in the medical area have as an objective to provide diagnosis or treatment to the ill patient. To obtain an image of good quality is fundamental, so that the doctor carries out a good diagnosis. The images depend on many physical factors, such as the type of the used equipment, ability of the operator that takes the badge, maintenance of the equipment, badge quality, etc. The images in which the diagnosis is based on are a gathering of gray different tones that draw the anatomy of interest. Therefore, an injury should have different physical characteristics (grosor, density) to stand out from its environment. This notable capacity is known as radiological contrast. Studies which allow the quantification of the radiation levels' effect, the optic badge densities and the observers' physical particularities for the detection of low-contrast objects have not been done in Costa Rica The physician is the one responsible of implementing the quality programs that lead to the gathering of better images. From now on, the asserted diagnosis falls right into the radiologist's experience, who receives the theoretical training and practices of the different diagnosed modalities during his or her residence's years. Besides, the radiologist can collaborate with the improvement of the accuracy of the diagnosis, if he or she recommends the

  16. New tubes and techniques for flash X-ray diffraction and high contrast radiography

    International Nuclear Information System (INIS)

    Charbonnier, F.M.; Barbour, J.P.; Brewster, J.L.

    High energy electrons are particularly efficient in producing characteristic X-rays and soft polychromatic. A line of wide spectrum beryllium window flash X-ray tubes, ranging from 150 to 600kV, has been developed to exploit this property. Laue and Debye Scherrer flash X-ray diffraction patterns have been obtained using a single 30 ns pulse exposure. X-ray diffraction tests obtained are shown. Extremely high contrast flash radiography of small, low density objects has been obtained using industrial film without screen. Alternatively, particularly at high voltages and for subjects which include a broad range of materials and thicknesses, special film techniques can be used to produce extremely wide latitudes. Equipment, techniques and results are discussed

  17. Embedded high-contrast distributed grating structures

    Science.gov (United States)

    Zubrzycki, Walter J.; Vawter, Gregory A.; Allerman, Andrew A.

    2002-01-01

    A new class of fabrication methods for embedded distributed grating structures is claimed, together with optical devices which include such structures. These new methods are the only known approach to making defect-free high-dielectric contrast grating structures, which are smaller and more efficient than are conventional grating structures.

  18. Prospective randomized comparison of standard didactic lecture versus high-fidelity simulation for radiology resident contrast reaction management training.

    Science.gov (United States)

    Wang, Carolyn L; Schopp, Jennifer G; Petscavage, Jonelle M; Paladin, Angelisa M; Richardson, Michael L; Bush, William H

    2011-06-01

    The objective of our study was to assess whether high-fidelity simulation-based training is more effective than traditional didactic lecture to train radiology residents in the management of contrast reactions. This was a prospective study of 44 radiology residents randomized into a simulation group versus a lecture group. All residents attended a contrast reaction didactic lecture. Four months later, baseline knowledge was assessed with a written test, which we refer to as the "pretest." After the pretest, the 21 residents in the lecture group attended a repeat didactic lecture and the 23 residents in the simulation group underwent high-fidelity simulation-based training with five contrast reaction scenarios. Next, all residents took a second written test, which we refer to as the "posttest." Two months after the posttest, both groups took a third written test, which we refer to as the "delayed posttest," and underwent performance testing with a high-fidelity severe contrast reaction scenario graded on predefined critical actions. There was no statistically significant difference between the simulation and lecture group pretest, immediate posttest, or delayed posttest scores. The simulation group performed better than the lecture group on the severe contrast reaction simulation scenario (p = 0.001). The simulation group reported improved comfort in identifying and managing contrast reactions and administering medications after the simulation training (p ≤ 0.04) and was more comfortable than the control group (p = 0.03), which reported no change in comfort level after the repeat didactic lecture. When compared with didactic lecture, high-fidelity simulation-based training of contrast reaction management shows equal results on written test scores but improved performance during a high-fidelity severe contrast reaction simulation scenario.

  19. Modeling the Subjective Quality of Highly Contrasted Videos Displayed on LCD With Local Backlight Dimming

    DEFF Research Database (Denmark)

    Mantel, Claire; Bech, Søren; Korhonen, Jari

    2015-01-01

    Local backlight dimming is a technology aiming at both saving energy and improving visual quality on television sets. As the rendition of the image is specified locally, the numerical signal corresponding to the displayed image needs to be computed through a model of the display. This simulated...... signal can then be used as input to objective quality metrics. The focus of this paper is on determining which characteristics of locally backlit displays influence quality assessment. A subjective experiment assessing the quality of highly contrasted videos displayed with various local backlight......-dimming algorithms is set up. Subjective results are then compared with both objective measures and objective quality metrics using different display models. The first analysis indicates that the most significant objective features are temporal variations, power consumption (probably representing leakage...

  20. Compressive Phase Contrast Tomography

    International Nuclear Information System (INIS)

    Maia, Filipe; MacDowell, Alastair; Marchesini, Stefano; Padmore, Howard A.; Parkinson, Dula Y.; Pien, Jack; Schirotzek, Andre; Yang, Chao

    2010-01-01

    When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. Interference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made of big blocks of a few components), such higher contrast datasets have a sparse solution. We apply basis pursuit solvers to improve SNR, remove ring artifacts, reduce the number of views and radiation dose from phase contrast datasets collected at the Hard X-Ray Micro Tomography Beamline at the Advanced Light Source. We report a GPU code for the most computationally intensive task, the gridding and inverse gridding algorithm (non uniform sampled Fourier transform).

  1. Efficacy of high iodine concentration contrast medium with saline pushing in hepatic CT in patients with chronic liver disease. Comparison of high doses-standard contrast medium concentration

    International Nuclear Information System (INIS)

    Matoba, Munetaka; Kondo, Tamaki; Nishikawa, Takahiro; Kuginuki, Yasuaki; Yokota, Hajime; Higashi, Kotaro; Tonami, Hisao

    2006-01-01

    The aim of this study was to compare the enhancement of liver parenchyama with high iodine concentration contrast medium with saline pushing to that with high doses standard iodine concentration in hepatic CT in patients with chronic liver disease. There was no statistically significant difference regarding to the enhancement of liver parenchyama between the 370 mgI/ml of contrast medium with saline pushing and high doses standard iodine concentration contrast medium. (author)

  2. X-ray phase contrast imaging of objects with subpixel-size inhomogeneities: a geometrical optics model.

    Science.gov (United States)

    Gasilov, Sergei V; Coan, Paola

    2012-09-01

    Several x-ray phase contrast extraction algorithms use a set of images acquired along the rocking curve of a perfect flat analyzer crystal to study the internal structure of objects. By measuring the angular shift of the rocking curve peak, one can determine the local deflections of the x-ray beam propagated through a sample. Additionally, some objects determine a broadening of the crystal rocking curve, which can be explained in terms of multiple refraction of x rays by many subpixel-size inhomogeneities contained in the sample. This fact may allow us to differentiate between materials and features characterized by different refraction properties. In the present work we derive an expression for the beam broadening in the form of a linear integral of the quantity related to statistical properties of the dielectric susceptibility distribution function of the object.

  3. High spatial resolution and high contrast visualization of brain arteries and veins. Impact of blood pool contrast agent and water-selective excitation imaging at 3T

    International Nuclear Information System (INIS)

    Spuentrup, E.; Jacobs, J.E.; Kleimann, J.F.

    2010-01-01

    Purpose: To investigate a blood pool contrast agent and water-selective excitation imaging at 3 T for high spatial and high contrast imaging of brain vessels including the veins. Methods and Results: 48 clinical patients (47 ± 18 years old) were included. Based on clinical findings, twenty-four patients received a single dose of standard extracellular Gadoterate-meglumine (Dotarem registered ) and 24 received the blood pool contrast agent Gadofosveset (Vasovist registered ). After finishing routine MR protocols, all patients were investigated with two high spatial resolution (0.15 mm 3 voxel size) gradient echo sequences in random order in the equilibrium phase (steady-state) as approved by the review board: A standard RF-spoiled gradient-echo sequence (HR-SS, TR/TE 5.1 / 2.3 msec, FA 30 ) and a fat-suppressed gradient-echo sequence with water-selective excitation (HR-FS, 1331 binominal-pulse, TR/TE 8.8 / 3.8 msec, FA 30 ). The images were subjectively assessed (image quality with vessel contrast, artifacts, depiction of lesions) by two investigators and contrast-to-noise ratios (CNR) were compared using the Student's t-test. The image quality and CNR in the HR-FS were significantly superior compared to the HR-SS for both contrast agents (p < 0.05). The CNR was also improved when using the blood pool agent but only to a minor extent while the subjective image quality was similar for both contrast agents. Conclusion: The utilized sequence with water-selective excitation improved image quality and CNR properties in high spatial resolution imaging of brain arteries and veins. The used blood pool contrast agent improved the CNR only to a minor extent over the extracellular contrast agent. (orig.)

  4. High contrast laser marking of alumina

    International Nuclear Information System (INIS)

    Penide, J.; Quintero, F.; Riveiro, A.; Fernández, A.; Val, J. del; Comesaña, R.; Lusquiños, F.; Pou, J.

    2015-01-01

    Highlights: • Laser marking of alumina using near infrared (NIR) lasers was experimentally analyzed. • Color change produced by NIR lasers is due to thermally induced oxygen vacancies. • Laser marking results obtained using NIR lasers and green laser are compared. • High contrast marks on alumina were achieved. - Abstract: Alumina serves as raw material for a broad range of advanced ceramic products. These elements should usually be identified by some characters or symbols printed directly on them. In this sense, laser marking is an efficient, reliable and widely implemented process in industry. However, laser marking of alumina still leads to poor results since the process is not able to produce a dark mark, yielding bad contrast. In this paper, we present an experimental study on the process of marking alumina by three different lasers working in two wavelengths: 1064 nm (Near-infrared) and 532 nm (visible, green radiation). A colorimetric analysis has been carried out in order to compare the resulting marks and its contrast. The most suitable laser operating conditions were also defined and are reported here. Moreover, the physical process of marking by NIR lasers is discussed in detail. Field Emission Scanning Electron Microscopy, High Resolution Transmission Electron Microscopy and X-ray Photoelectron Spectroscopy were also employed to analyze the results. Finally, we propose an explanation for the differences of the coloration induced under different atmospheres and laser parameters. We concluded that the atmosphere is the key parameter, being the inert one the best choice to produce the darkest marks

  5. High-contrast MacNeille-PBS-based LCOS projection systems

    Science.gov (United States)

    Chen, Jianmin; Robinson, Michael G.; Sharp, Gary D.

    2005-04-01

    Contrast limits are investigated for MacNeille PBS based LCOS projection systems that use retarder stack filters (RSF). The two contributing factors are considered separately; namely the color management system and the panel port. To enhance performance of the former, skew ray compensated RSFs are introduced. For the latter, a general methodology is presented to optimize contrast by compensating the LCOS panel. It is shown that the orientation of the LCOS panel and compensator, relative to the MacNeille PBS, is critical. The significant impact of AR coating performance on system contrast is also revealed. A high contrast architecture will be presented by way of example.

  6. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Zhang, Kai [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhu, Peiping; Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China and Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

  7. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili; Zhang, Kai; Zhu, Peiping; Wu, Ziyu

    2015-01-01

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations

  8. Gd-HOPO Based High Relaxivity MRI Contrast Agents

    Energy Technology Data Exchange (ETDEWEB)

    Datta, Ankona; Raymond, Kenneth

    2008-11-06

    Tris-bidentate HOPO-based ligands developed in our laboratory were designed to complement the coordination preferences of Gd{sup 3+}, especially its oxophilicity. The HOPO ligands provide a hexadentate coordination environment for Gd{sup 3+} in which all he donor atoms are oxygen. Because Gd{sup 3+} favors eight or nine coordination, this design provides two to three open sites for inner-sphere water molecules. These water molecules rapidly exchange with bulk solution, hence affecting the relaxation rates of bulk water olecules. The parameters affecting the efficiency of these contrast agents have been tuned to improve contrast while still maintaining a high thermodynamic stability for Gd{sup 3+} binding. The Gd- HOPO-based contrast agents surpass current commercially available agents ecause of a higher number of inner-sphere water molecules, rapid exchange of inner-sphere water molecules via an associative mechanism, and a long electronic relaxation time. The contrast enhancement provided by these agents is at least twice that of commercial contrast gents, which are based on polyaminocarboxylate ligands.

  9. Effect of intensifying screens to subject contrast

    International Nuclear Information System (INIS)

    Lee, In Ja; Huh, Joon; Kang, Hong Seok; Yoon, Chul Ho

    1990-01-01

    It is an experimental report about object contrast according to the Kinds of screen and obtained results as follows ; 1. In the same object radiography, use acquired the difference of the object contrast between LT-II(CaWO 4 system) and G4(Gd system) screens. 2. object contrast more decreased in Gd system screen than CaWO 4 and object contrast controlled by X-ray tube voltage. 3. The difference of object contrast seen clearly in 80 kVp

  10. High contrast sensitivity for visually guided flight control in bumblebees.

    Science.gov (United States)

    Chakravarthi, Aravin; Kelber, Almut; Baird, Emily; Dacke, Marie

    2017-12-01

    Many insects rely on vision to find food, to return to their nest and to carefully control their flight between these two locations. The amount of information available to support these tasks is, in part, dictated by the spatial resolution and contrast sensitivity of their visual systems. Here, we investigate the absolute limits of these visual properties for visually guided position and speed control in Bombus terrestris. Our results indicate that the limit of spatial vision in the translational motion detection system of B. terrestris lies at 0.21 cycles deg -1 with a peak contrast sensitivity of at least 33. In the perspective of earlier findings, these results indicate that bumblebees have higher contrast sensitivity in the motion detection system underlying position control than in their object discrimination system. This suggests that bumblebees, and most likely also other insects, have different visual thresholds depending on the behavioral context.

  11. High contrast computed tomography with synchrotron radiation

    Science.gov (United States)

    Itai, Yuji; Takeda, Tohoru; Akatsuka, Takao; Maeda, Tomokazu; Hyodo, Kazuyuki; Uchida, Akira; Yuasa, Tetsuya; Kazama, Masahiro; Wu, Jin; Ando, Masami

    1995-02-01

    This article describes a new monochromatic x-ray CT system using synchrotron radiation with applications in biomedical diagnosis which is currently under development. The system is designed to provide clear images and to detect contrast materials at low concentration for the quantitative functional evaluation of organs in correspondence with their anatomical structures. In this system, with x-ray energy changing from 30 to 52 keV, images can be obtained to detect various contrast materials (iodine, barium, and gadolinium), and K-edge energy subtraction is applied. Herein, the features of the new system designed to enhance the advantages of SR are reported. With the introduction of a double-crystal monochromator, the high-order x-ray contamination is eliminated. The newly designed CCD detector with a wide dynamic range of 60 000:1 has a spatial resolution of 200 μm. The resulting image quality, which is expected to show improved contrast and spatial resolution, is currently under investigation.

  12. Phase contrast imaging with coherent high energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Snigireva, I. [ESRF, Grenoble (France)

    1997-02-01

    X-ray imaging concern high energy domain (>6 keV) like a contact radiography, projection microscopy and tomography is used for many years to discern the features of the internal structure non destructively in material science, medicine and biology. In so doing the main contrast formation is absorption that makes some limitations for imaging of the light density materials and what is more the resolution of these techniques is not better than 10-100 {mu}m. It was turned out that there is now way in which to overcome 1{mu}m or even sub-{mu}m resolution limit except phase contrast imaging. It is well known in optics that the phase contrast is realised when interference between reference wave front and transmitted through the sample take place. Examples of this imaging are: phase contrast microscopy suggested by Zernike and Gabor (in-line) holography. Both of this techniques: phase contrast x-ray microscopy and holography are successfully progressing now in soft x-ray region. For imaging in the hard X-rays to enhance the contrast and to be able to resolve phase variations across the beam the high degree of the time and more importantly spatial coherence is needed. Because of this it was reasonable that the perfect crystal optics was involved like Bonse-Hart interferometry, double-crystal and even triple-crystal set-up using Laue and Bragg geometry with asymmetrically cut crystals.

  13. High contrast high intensity petawatt J-KAREN-P laser facility at QST

    Science.gov (United States)

    Nishiuchi, Mamiko; Kiriyama, Hiromitsu; Sakaki, Hironao; Dover, Nicholas P.; Kondo, Kotaro; Pirozhkov, Alexander S.; Sagisaka, Akito; Fukuda, Yuji; Nishitani, Keita; Miyahara, Takumi; Ogura, Koichi; Alkhimova, Mariya A.; Pikuz, Tatiana A.; Faenov, Anatoly Y.; Watanabe, Yukinobu; Koga, James; Bulanov, Sergei V.; Kando, Masaki; Kondo, Kiminori

    2017-05-01

    We report on the J-KAREN-P laser facility at QST, which can provide PW peak power at 0.1 Hz on target. The system can deliver short pulses with an energy of 30 J and pulse duration of 30 fs after compression with a contrast level of better than 1012. Such performance in high field science will give rise to the birth of new applications and breakthroughs, which include relativistic particle acceleration, bright x-ray source generation, and nuclear activation. The current achieved laser intensity on target is up to > 9x1021 Wcm-2 with an energy of 9 J on target. The interaction with a 3 to 5- μm stainless steel tape target provides us electrons with a typical temperature of more than 10 MeV and energetic proton beams with typical maximum energies of > 40 MeV with good reproducibility. The protons are accelerated in the Target Normal Sheath Acceleration regime, which is suitable for many applications including as an injector into a beamline for medical use, which is one of our objectives.

  14. Progress in high index contrast integrated optics

    NARCIS (Netherlands)

    Baets, R.G.F.; Bienstman, P.; Bogaerts, W.; Brouckaert, J.; De Backere, P.; Dumon, P.; Roelkens, G.; Scheerlinck, S.; Smit, M.K.; Taillaert, D.; Van Campenhout, J.; Van Laere, F.; Thourhout, Van D.

    2007-01-01

    A large fraction of the recent innovation in integrated optics is enabled by the use of high index contrast structures and devices. The strong confinement achievable in such devices allows for dramatic performance benefits and downscaling. In this paper the progress in this field is reviewed.

  15. High-contrast direct imaging of exo-planets and circumstellar disks: from the self-coherent camera to NICI data analysis

    International Nuclear Information System (INIS)

    Mazoyer, Johan

    2014-01-01

    Out of the 1800 exo-planets detected to date, only 50 were by direct imaging. However, by allowing the observation of circumstellar disks and planets (sometimes simultaneously around the same star, as in the case of β-pictoris), this method is a fundamental tool for the understanding of planetary formation. In addition, direct access to the light of the detected objects allows spectroscopy, paving the way for the first time to the chemical and thermal analysis of their atmosphere and surface. However, direct imaging raises specific challenges: accessing objects fainter than their star (with a ration up to 10"-"8 to 10"-"1"1), and separated only by a fraction of arc-second. To obtain these values, several techniques must be implemented. A corona-graph, used in complement with a deformable mirror and active optical aberration correction methods, produces high-contrast images, which can be further processed by differential imaging techniques. My PhD thesis work took place at the intersection of these techniques. At first, I analyzed, in simulation and experimentally on the THD 'French acronym for very high contrast' bench of the Paris Observatory, the performance of the self-coherent camera, a wavefront sensing technique used to correct the optical aberrations in the focal plane. I managed to obtained high-contrast zones (called dark holes) with performance up to 3.10"-"8 between 5 and 12?/D, in monochromatic light. I also started an analysis of the performance in narrow spectral bands. In the second part of my thesis, I applied the latest differential imaging techniques to high contrast images from another corona-graphic instrument, NICI. The processing of these data revealed unprecedented views of the dust disk orbiting HD 15115. (author)

  16. Improvements in gastric diagnosis by using high density contrast media with low viscosity

    International Nuclear Information System (INIS)

    Toischer, H.P.

    1983-01-01

    In a retrospective clinical study, 150 unselected double contrast examinations of the stomach using conventional contrast media (100 g/100 ml barium sulphate) were compared with a similar number of examinations using a high density contrast medium of flow viscosity (250 g/100 ml barium sulphate). The high density contrast medium was distinctly better for demonstrating detail of the gastric mucosa. The uneveness of coating and instability of the older high density contrast media was observed in 15.5% of cases and, in no instance, did this make it impossible to reach a diagnosis. (orig.) [de

  17. X-ray Phase Contrast analysis - Digital wavefront development

    International Nuclear Information System (INIS)

    Idir, Mourad; Potier, Jonathan; Fricker, Sebastien; Snigirev, Anatoly; Snigireva, Irina; Modi, M. H.

    2010-01-01

    Optical schemes that enable imaging of the phase shift produced by an object have become popular in the x-ray region, where phase can be the dominant contrast mechanism. The propagation-based technique consists of recording the interference pattern produced by choosing one or several sample-to-detector distances. Pioneering studies, carried out making use of synchrotron radiation, demonstrated that this technique results in a dramatic increase of image contrast and detail visibility, allowing the detection of structures invisible with conventional techniques. An experimental and theoretical study of in-line hard x-ray phase-contrast imaging had been performed. The theoretical description of the technique is based on Fresnel diffraction. As an illustration of the potential of this quantitative imaging technique, high-resolution x-ray phase contrast images of simple objects will be presented.

  18. The advantage of high relaxivity contrast agents in brain perfusion

    International Nuclear Information System (INIS)

    Cotton, F.; Hermier, M.

    2006-01-01

    Accurate MRI characterization of brain lesions is critical for planning therapeutic strategy, assessing prognosis and monitoring response to therapy. Conventional MRI with gadolinium-based contrast agents is useful for the evaluation of brain lesions, but this approach primarily depicts areas of disruption of the blood-brain barrier (BBB) rather than tissue perfusion. Advanced MR imaging techniques such as dynamic contrast agent-enhanced perfusion MRI provide physiological information that complements the anatomic data available from conventional MRI. We evaluated brain perfusion imaging with gadobenate dimeglumine (Gd-BOPTA, MultiHance; Bracco Imaging, Milan, Italy). The contrast-enhanced perfusion technique was performed on a Philips Intera 1.5-T MR system. The technique used to obtain perfusion images was dynamic susceptibility contrast-enhanced MRI, which is highly sensitive to T2* changes. Combined with PRESTO perfusion imaging, SENSE is applied to double the temporal resolution, thereby improving the signal intensity curve fit and, accordingly, the accuracy of the derived parametric images. MultiHance is the first gadolinium MR contrast agent with significantly higher T1 and T2 relaxivities than conventional MR contrast agents. The higher T1 relaxivity, and therefore better contrast-enhanced T1-weighted imaging, leads to significantly improved detection of BBB breakdown and hence improved brain tumor conspicuity and delineation. The higher T2 relaxivity allows high-quality T2*-weighted perfusion MRI and the derivation of good quality relative cerebral blood volume (rCBV) maps. We determined the value of MultiHance for enhanced T2*-weighted perfusion imaging of histologically proven (by surgery or stereotaxic biopsy) intraaxial brain tumors (n=80), multiple sclerosis lesions (n=10), abscesses (n=4), neurolupus (n=15) and stroke (n=16). All the procedures carried out were safe and no adverse events occurred. The acquired perfusion images were of good quality in

  19. Improved specimen reconstruction by Hilbert phase contrast tomography.

    Science.gov (United States)

    Barton, Bastian; Joos, Friederike; Schröder, Rasmus R

    2008-11-01

    The low signal-to-noise ratio (SNR) in images of unstained specimens recorded with conventional defocus phase contrast makes it difficult to interpret 3D volumes obtained by electron tomography (ET). The high defocus applied for conventional tilt series generates some phase contrast but leads to an incomplete transfer of object information. For tomography of biological weak-phase objects, optimal image contrast and subsequently an optimized SNR are essential for the reconstruction of details such as macromolecular assemblies at molecular resolution. The problem of low contrast can be partially solved by applying a Hilbert phase plate positioned in the back focal plane (BFP) of the objective lens while recording images in Gaussian focus. Images recorded with the Hilbert phase plate provide optimized positive phase contrast at low spatial frequencies, and the contrast transfer in principle extends to the information limit of the microscope. The antisymmetric Hilbert phase contrast (HPC) can be numerically converted into isotropic contrast, which is equivalent to the contrast obtained by a Zernike phase plate. Thus, in-focus HPC provides optimal structure factor information without limiting effects of the transfer function. In this article, we present the first electron tomograms of biological specimens reconstructed from Hilbert phase plate image series. We outline the technical implementation of the phase plate and demonstrate that the technique is routinely applicable for tomography. A comparison between conventional defocus tomograms and in-focus HPC volumes shows an enhanced SNR and an improved specimen visibility for in-focus Hilbert tomography.

  20. Contrast enhanced cartilage imaging: Comparison of ionic and non-ionic contrast agents

    International Nuclear Information System (INIS)

    Wiener, Edzard; Woertler, Klaus; Weirich, Gregor; Rummeny, Ernst J.; Settles, Marcus

    2007-01-01

    Our objective was to compare relaxation effects, dynamics and spatial distributions of ionic and non-ionic contrast agents in articular cartilage at concentrations typically used for direct MR arthrography at 1.5 T. Dynamic MR-studies over 11 h were performed in 15 bovine patella specimens. For each of the contrast agents gadopentetate dimeglumine, gadobenate dimeglumine, gadoteridol and mangafodipir trinatrium three patellae were placed in 2.5 mmol/L contrast solution. Simultaneous measurements of T 1 and T 2 were performed every 30 min using a high-spatial-resolution 'MIX'-sequence. T 1 , T 2 and ΔR 1 , ΔR 2 profile plots across cartilage thickness were calculated to demonstrate the spatial and temporal distributions. The charge is one of the main factors which controls the amount of the contrast media diffusing into intact cartilage, but independent of the charge, the spatial distribution across cartilage thickness remains highly inhomogeneous even after 11 h of diffusion. The absolute ΔR 2 -effect in cartilage is at least as large as the ΔR 1 -effect for all contrast agents. Maximum changes were 5-12 s -1 for ΔR 1 and 8-15 s -1 for ΔR 2 . This study indicates that for morphologically intact cartilage only the amount of contrast agents within cartilage is determined by the charge but not the spatial distribution across cartilage thickness. In addition, ΔR 2 can be considered for quantification of contrast agent concentrations, since it is of the same magnitude and less time consuming to measure than ΔR 1

  1. Domain Decomposition Preconditioners for Multiscale Flows in High-Contrast Media

    KAUST Repository

    Galvis, Juan; Efendiev, Yalchin

    2010-01-01

    In this paper, we study domain decomposition preconditioners for multiscale flows in high-contrast media. We consider flow equations governed by elliptic equations in heterogeneous media with a large contrast in the coefficients. Our main goal is to develop domain decomposition preconditioners with the condition number that is independent of the contrast when there are variations within coarse regions. This is accomplished by designing coarse-scale spaces and interpolators that represent important features of the solution within each coarse region. The important features are characterized by the connectivities of high-conductivity regions. To detect these connectivities, we introduce an eigenvalue problem that automatically detects high-conductivity regions via a large gap in the spectrum. A main observation is that this eigenvalue problem has a few small, asymptotically vanishing eigenvalues. The number of these small eigenvalues is the same as the number of connected high-conductivity regions. The coarse spaces are constructed such that they span eigenfunctions corresponding to these small eigenvalues. These spaces are used within two-level additive Schwarz preconditioners as well as overlapping methods for the Schur complement to design preconditioners. We show that the condition number of the preconditioned systems is independent of the contrast. More detailed studies are performed for the case when the high-conductivity region is connected within coarse block neighborhoods. Our numerical experiments confirm the theoretical results presented in this paper. © 2010 Society for Industrial and Applied Mathematics.

  2. Digital breast tomosynthesis: studies of the effects of acquisition geometry on contrast-to-noise ratio and observer preference of low-contrast objects in breast phantom images

    International Nuclear Information System (INIS)

    Goodsitt, Mitchell M; Chan, Heang-Ping; Telang, Santosh; Hadjiiski, Lubomir; Helvie, Mark A; Paramagul, Chintana; Neal, Colleen; Christodoulou, Emmanuel; Larson, Sandra C; Carson, Paul L; Schmitz, Andrea; Zelakiewicz, Scott; Watcharotone, Kuanwong

    2014-01-01

    The effect of acquisition geometry in digital breast tomosynthesis was evaluated with studies of contrast-to-noise ratios (CNRs) and observer preference. Contrast-detail (CD) test objects in 5 cm thick phantoms with breast-like backgrounds were imaged. Twelve different angular acquisitions (average glandular dose for each ∼1.1 mGy) were performed ranging from narrow angle 16° with 17 projection views (16d17p) to wide angle 64d17p. Focal slices of SART-reconstructed images of the CD arrays were selected for CNR computations and the reader preference study. For the latter, pairs of images obtained with different acquisition geometries were randomized and scored by 7 trained readers. The total scores for all images and readings for each acquisition geometry were compared as were the CNRs. In general, readers preferred images acquired with wide angle as opposed to narrow angle geometries. The mean percent preferred was highly correlated with tomosynthesis angle (R = 0.91). The highest scoring geometries were 60d21p (95%), 64d17p (80%), and 48d17p (72%); the lowest scoring were 16d17p (4%), 24d9p (17%) and 24d13p (33%). The measured CNRs for the various acquisitions showed much overlap but were overall highest for wide-angle acquisitions. Finally, the mean reader scores were well correlated with the mean CNRs (R = 0.83). (paper)

  3. Digital breast tomosynthesis: Studies of the effects of acquisition geometry on contrast-to-noise ratio and observer preference of low-contrast objects in breast phantom images

    Science.gov (United States)

    Goodsitt, Mitchell M.; Chan, Heang-Ping; Schmitz, Andrea; Zelakiewicz, Scott; Telang, Santosh; Hadjiiski, Lubomir; Watcharotone, Kuanwong; Helvie, Mark A.; Paramagul, Chintana; Neal, Colleen; Christodoulou, Emmanuel; Larson, Sandra C.; Carson, Paul L.

    2014-01-01

    The effect of acquisition geometry in digital breast tomosynthesis (DBT) was evaluated with studies of contrast-to-noise ratios (CNRs) and observer preference. Contrast-detail (CD) test objects in 5 cm thick phantoms with breast-like backgrounds were imaged. Twelve different angular acquisitions (average glandular dose for each ~1.1 mGy) were performed ranging from narrow angle 16° with 17 projection views (16d17p) to wide angle 64d17p. Focal slices of SART-reconstructed images of the CD arrays were selected for CNR computations and the reader preference study. For the latter, pairs of images obtained with different acquisition geometries were randomized and scored by 7 trained readers. The total scores for all images and readings for each acquisition geometry were compared as were the CNRs. In general, readers preferred images acquired with wide angle as opposed to narrow angle geometries. The mean percent preferred was highly correlated with tomosynthesis angle (R=0.91). The highest scoring geometries were 60d21p (95%), 64d17p (80%), and 48d17p (72%); the lowest scoring were 16d17p (4%), 24d9p (17%) and 24d13p (33%). The measured CNRs for the various acquisitions showed much overlap but were overall highest for wide-angle acquisitions. Finally, the mean reader scores were well correlated with the mean CNRs (R=0.83). PMID:25211509

  4. A systematic approach towards the objective evaluation of low-contrast performance in MDCT: Combination of a full-reference image fidelity metric and a software phantom

    International Nuclear Information System (INIS)

    Falck, Christian von; Rodt, Thomas; Waldeck, Stephan; Hartung, Dagmar; Meyer, Bernhard; Wacker, Frank; Shin, Hoen-oh

    2012-01-01

    Objectives: To assess the feasibility of an objective approach for the evaluation of low-contrast detectability in multidetector computed-tomography (MDCT) by combining a virtual phantom containing simulated lesions with an image quality metric. Materials and methods: A low-contrast phantom containing hypodense spheric lesions (−20 HU) was scanned on a 64-slice MDCT scanner at 4 different dose levels (25, 50, 100, 200 mAs). In addition, virtual round hypodense low-contrast lesions (20 HU object contrast) based on real CT data were inserted into the lesion-free section of the datasets. The sliding-thin-slab algorithm was applied to the image data with an increasing slice-thickness from 1 to 15 slices. For each dataset containing simulated lesions a lesion-free counterpart was reconstructed and post-processed in the same manner. The low-contrast performance of all datasets containing virtual lesions was determined using a full-reference image quality metric (modified multiscale structural similarity index, MS-SSIM*). The results were validated against a reader-study of the real lesions. Results: For all dose levels and lesion sizes there was no statistically significant difference between the low-contrast performance as determined by the image quality metric when compared to the reader study (p < 0.05). The intraclass correlation coefficient was 0.72, 0.82, 0.90 and 0.84 for lesion diameters of 4 mm, 5 mm, 8 mm and 10 mm, respectively. The use of the sliding-thin-slab algorithm improves lesion detectability by a factor ranging from 1.15 to 2.69 when compared with the original axial slice (0.625 mm). Conclusion: The combination of a virtual phantom and a full-reference image quality metric enables a systematic, automated and objective evaluation of low-contrast detectability in MDCT datasets and correlates well with the judgment of human readers.

  5. High-contrast coronagraph performance in the presence of DM actuator defects

    Science.gov (United States)

    Sidick, Erkin; Shaklan, Stuart; Cady, Eric

    2015-09-01

    Deformable Mirrors (DMs) are critical elements in high contrast coronagraphs, requiring precision and stability measured in picometers to enable detection of Earth-like exoplanets. Occasionally DM actuators or their associated cables or electronics fail, requiring a wavefront control algorithm to compensate for actuators that may be displaced from their neighbors by hundreds of nanometers. We have carried out experiments on our High-Contrast Imaging Testbed (HCIT) to study the impact of failed actuators in partial fulfilment of the Terrestrial Planet Finder Coronagraph optical model validation milestone. We show that the wavefront control algorithm adapts to several broken actuators and maintains dark-hole contrast in broadband light.

  6. High-Contrast Coronagraph Performance in the Presence of DM Actuator Defects

    Science.gov (United States)

    Sidick, Erkin; Shaklan, Stuart; Cady, Eric

    2015-01-01

    Deformable Mirrors (DMs) are critical elements in high contrast coronagraphs, requiring precision and stability measured in picometers to enable detection of Earth-like exoplanets. Occasionally DM actuators or their associated cables or electronics fail, requiring a wavefront control algorithm to compensate for actuators that may be displaced from their neighbors by hundreds of nanometers. We have carried out experiments on our High-Contrast Imaging Testbed (HCIT) to study the impact of failed actuators in partial fulfillment of the Terrestrial Planet Finder Coronagraph optical model validation milestone. We show that the wavefront control algorithm adapts to several broken actuators and maintains dark-hole contrast in broadband light.

  7. High-contrast x-ray microtomography in dental research

    Science.gov (United States)

    Davis, Graham; Mills, David

    2017-09-01

    X-ray microtomography (XMT) is a well-established technique in dental research. The technique has been used extensively to explore the complex morphology of the root canal system, and to qualitatively and quantitatively evaluate root canal instrumentation and filling efficacy in extracted teeth; enabling different techniques to be compared. Densitometric information can be used to identify and map demineralized tissue resulting from tooth decay (caries) and, in extracted teeth, the method can be used to evaluate different methods of excavation. More recently, high contrast XMT is being used to investigate the relationship between external insults to teeth and the pulpal reaction. When such insults occur, fluid may flow through dentinal tubules as a result of cracking or porosity in enamel. Over time, there is an increase in mineralization along the paths of the tubules from the pulp to the damaged region in enamel and this can be visualized using high contrast XMT. The scanner used for this employs time-delay integration to minimize the effects of detector inhomogeneity in order to greatly increase the upper limit on signal-to-noise ratio that can be achieved with long exposure times. When enamel cracks are present in extracted teeth, the presence of these pathways indicates that the cracking occurred prior to extraction. At high contrast, growth lines are occasionally seen in deciduous teeth which may have resulted from periods of maternal illness. Various other anomalies in mineralization resulting from trauma or genetic abnormalities can also be investigated using this technique.

  8. Polarization-Independent Wideband High-Index-Contrast Grating Mirror

    DEFF Research Database (Denmark)

    Bekele, Dagmawi Alemayehu; Park, Gyeong Cheol; Malureanu, Radu

    2015-01-01

    Island-type two-dimensional high-index-contrast grating mirror based on a standard silicon-on-insulator wafer have been experimentally demonstrated. The measured spectra shows a bandwidth of ∼192 nm with a reflectivity over 99% as well as polarization independence. Numerical simulations show...

  9. Liver imaging with MDCT and high concentration contrast media

    International Nuclear Information System (INIS)

    Spielmann, Audrey L.

    2003-01-01

    Liver imaging has advanced greatly over the last 10 years with helical CT capability and more recently the addition of multidetector-row CT (MDCT). Multidetector CT technology facilitates imaging at faster speeds with improved image quality and less breathing artifact [Abdom. Imaging 25 (2000) 643]. Exquisite three-dimensional data sets can be obtained with thin collimation providing improved lesion detection, multiplanar imaging, and the ability to perform CT angiography of the liver and mesenteric vessels. New challenges arise with this advance in technology including safety considerations. The radiation dose to the patient has increased with MDCT and this is compounded by the ability to perform multi-phase liver imaging. Furthermore, issues of contrast media administration require reconsideration including optimal timing and rate of administration, the total volume of contrast needed and the ideal iodine concentration of the contrast media. Recently, the use of high concentration contrast media (HCCM) has been explored and study results to date will be reviewed

  10. The optimal use of contrast agents at high field MRI

    International Nuclear Information System (INIS)

    Trattnig, Siegfried; Pinker, Kathia; Ba-Ssalamah, Ahmed; Noebauer-Huhmann, Iris-Melanie

    2006-01-01

    The intravenous administration of a standard dose of conventional gadolinium-based contrast agents produces higher contrast between the tumor and normal brain at 3.0 Tesla (T) than at 1.5 T, which allows reducing the dose to half of the standard one to produce similar contrast at 3.0 T compared to 1.5 T. The assessment of cumulative triple-dose 3.0 T images obtained the best results in the detection of brain metastases compared to other sequences. The contrast agent dose for dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging at 3.0 T can be reduced to 0.1 mmol compared to 0.2 mmol at 1.5 T due to the increased susceptibility effects at higher magnetic field strengths. Contrast agent application makes susceptibility-weighted imaging (SWI) at 3.0 T clinically attractive, with an increase in spatial resolution within the same scan time. Whereas a double dose of conventional gadolinium-based contrast agents was optimal in SWI with respect to sensitivity and image quality, a standard dose of gadobenate dimeglumine, which has a two-fold higher T1-relaxivity in blood, produced the same effect. For MR-arthrography, optimized concentrations of gadolinium-based contrast agents are similar at 3.0 and 1.5 T. In summary, high field MRI requires the optimization of the contrast agent dose in different clinical applications. (orig.)

  11. High-contrast multimodel nonlinear optical imaging of collagen and elastin

    Energy Technology Data Exchange (ETDEWEB)

    Zhuo, S M [Key Laboratory of Optoelectronic Science and Technology for Medicine (Fujian Normal University), Ministry of Education, Fuzhou 350007 (China); Chen, J X [Key Laboratory of Optoelectronic Science and Technology for Medicine (Fujian Normal University), Ministry of Education, Fuzhou 350007 (China); Luo, T S [Key Laboratory of Optoelectronic Science and Technology for Medicine (Fujian Normal University), Ministry of Education, Fuzhou 350007 (China); Chen, H L [Key Laboratory of Optoelectronic Science and Technology for Medicine (Fujian Normal University), Ministry of Education, Fuzhou 350007 (China); Zhao, J J [Department of Skin, Affiliated Xiehe Hospital, Fujian Medical University, Fuzhou 350001 (China)

    2007-07-15

    Collagen and elastin, as the major components in the extracellular matrix (ECM), are intrinsic indicators of physiological and pathological states. Here, we have developed a high-contrast multimodel nonlinear optical imaging technique to imaging collagen and elastin by detecting simultaneously two photon-excited fluorescence (TPEF) from elastin and second-harmonic generation (SHG) from collagen. Our results show that this technique can obtain a high-contrast TPEF/SHG image in human dermis and permit direct visualization of collagen and elastin. It was shown that the technique can provide collagen and elastin structural information to determine collagen and elastin fibril orientation and distribution and acquire some morphometric properties. It was found that the in-depth TPEF/SHG imaging and 3-D reconstruction of TPEF/SHG images can extract more collagen and elastin structural and biochemical information. The study results suggest that the high-contrast multimodel nonlinear imaging provides a powerful tool to study ECM intrinsic components and has the potential to provide more important information for the diagnosis of tissue.

  12. High-contrast multimodel nonlinear optical imaging of collagen and elastin

    International Nuclear Information System (INIS)

    Zhuo, S M; Chen, J X; Luo, T S; Chen, H L; Zhao, J J

    2007-01-01

    Collagen and elastin, as the major components in the extracellular matrix (ECM), are intrinsic indicators of physiological and pathological states. Here, we have developed a high-contrast multimodel nonlinear optical imaging technique to imaging collagen and elastin by detecting simultaneously two photon-excited fluorescence (TPEF) from elastin and second-harmonic generation (SHG) from collagen. Our results show that this technique can obtain a high-contrast TPEF/SHG image in human dermis and permit direct visualization of collagen and elastin. It was shown that the technique can provide collagen and elastin structural information to determine collagen and elastin fibril orientation and distribution and acquire some morphometric properties. It was found that the in-depth TPEF/SHG imaging and 3-D reconstruction of TPEF/SHG images can extract more collagen and elastin structural and biochemical information. The study results suggest that the high-contrast multimodel nonlinear imaging provides a powerful tool to study ECM intrinsic components and has the potential to provide more important information for the diagnosis of tissue

  13. Contextual effects on perceived contrast: figure-ground assignment and orientation contrast.

    Science.gov (United States)

    Self, Matthew W; Mookhoek, Aart; Tjalma, Nienke; Roelfsema, Pieter R

    2015-02-02

    Figure-ground segregation is an important step in the path leading to object recognition. The visual system segregates objects ('figures') in the visual scene from their backgrounds ('ground'). Electrophysiological studies in awake-behaving monkeys have demonstrated that neurons in early visual areas increase their firing rate when responding to a figure compared to responding to the background. We hypothesized that similar changes in neural firing would take place in early visual areas of the human visual system, leading to changes in the perception of low-level visual features. In this study, we investigated whether contrast perception is affected by figure-ground assignment using stimuli similar to those in the electrophysiological studies in monkeys. We measured contrast discrimination thresholds and perceived contrast for Gabor probes placed on figures or the background and found that the perceived contrast of the probe was increased when it was placed on a figure. Furthermore, we tested how this effect compared with the well-known effect of orientation contrast on perceived contrast. We found that figure-ground assignment and orientation contrast produced changes in perceived contrast of a similar magnitude, and that they interacted. Our results demonstrate that figure-ground assignment influences perceived contrast, consistent with an effect of figure-ground assignment on activity in early visual areas of the human visual system. © 2015 ARVO.

  14. Laser-matter interaction at high intensity and high temporal contrast

    International Nuclear Information System (INIS)

    Doumy, G.

    2006-01-01

    The continuous progress in the development of laser installations has already lead to ultra-short pulses capable of achieving very high focalized intensities (I > 10 18 W/cm 2 ). At these intensities, matter presents new non-linear behaviours, due to the fact that the electrons are accelerated to relativistic speeds. The experimental access to this interaction regime on solid targets has long been forbidden because of the presence, alongside the femtosecond pulse, of a pedestal (mainly due to the amplified spontaneous emission (ASE) which occurs in the laser chain) intense enough to modify the state of the target. In this thesis, we first characterized, both experimentally and theoretically, a device which allows an improvement of the temporal contrast of the pulse: the Plasma Mirror. It consists in adjusting the focusing of the pulse on a dielectric target, so that the pedestal is mainly transmitted, while the main pulse is reflected by the overcritical plasma that it forms at the surface. The implementation of such a device on the UHI 10 laser facility (CEA Saclay - 10 TW - 60 fs) then allowed us to study the interaction between ultra-intense, high contrast pulses with solid targets. In a first part, we managed to generate and characterize dense plasmas resulting directly from the interaction between the main pulse and very thin foils (100 nm). This characterization was realized by using an XUV source obtained by high order harmonics generation in a rare gas jet. In a second part, we studied experimentally the phenomenon of high order harmonics generation on solid targets, which is still badly understood, but could potentially lead to a new kind of energetic ultra-short XUV sources. (author)

  15. Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue

    International Nuclear Information System (INIS)

    Jakubek, Jan; Granja, Carlos; Dammer, Jiri; Hanus, Robert; Holy, Tomas; Pospisil, Stanislav; Tykva, Richard; Uher, Josef; Vykydal, Zdenek

    2007-01-01

    A tabletop system for digital high resolution and high sensitivity X-ray micro-radiography has been developed for small-animal and soft-tissue imaging. The system is based on a micro-focus X-ray tube and the semiconductor hybrid position sensitive Medipix2 pixel detector. Transmission radiography imaging, conventionally based only on absorption, is enhanced by exploiting phase-shift effects induced in the X-ray beam traversing the sample. Phase contrast imaging is realized by object edge enhancement. DAQ is done by a novel fully integrated USB-based readout with online image generation. Improved signal reconstruction techniques make use of advanced statistical data analysis, enhanced beam hardening correction and direct thickness calibration of individual pixels. 2D and 3D micro-tomography images of several biological samples demonstrate the applicability of the system for biological and medical purposes including in-vivo and time dependent physiological studies in the life sciences

  16. The V-SHARK high contrast imager at LBT

    Science.gov (United States)

    Pedichini, F.; Ambrosino, F.; Centrone, M.; Farinato, J.; Li Causi, G.; Pinna, E.; Puglisi, A.; Stangalini, M.; Testa, V.

    2016-08-01

    In the framework of the SHARK project the visible channel is a novel instrument synergic to the NIR channel and exploiting the performances of the LBT XAO at visible wavelengths. The status of the project is presented together with the design study of this innovative instrument optimized for high contrast imaging by means of high frame rate. Its expected results will be presented comparing the simulations with the real data of the "Forerunner" experiment taken at 630nm.

  17. Line-scanning confocal microscopy for high-resolution imaging of upconverting rare-earth-based contrast agents

    Science.gov (United States)

    Higgins, Laura M.; Zevon, Margot; Ganapathy, Vidya; Sheng, Yang; Tan, Mei Chee; Riman, Richard E.; Roth, Charles M.; Moghe, Prabhas V.; Pierce, Mark C.

    2015-01-01

    Abstract. Rare-earth (RE) doped nanocomposites emit visible luminescence when illuminated with continuous wave near-infrared light, making them appealing candidates for use as contrast agents in biomedical imaging. However, the emission lifetime of these materials is much longer than the pixel dwell times used in scanning intravital microscopy. To overcome this limitation, we have developed a line-scanning confocal microscope for high-resolution, optically sectioned imaging of samples labeled with RE-based nanomaterials. Instrument performance is quantified using calibrated test objects. NaYF4:Er,Yb nanocomposites are imaged in vitro, and in ex vivo tissue specimens, with direct comparison to point-scanning confocal microscopy. We demonstrate that the extended pixel dwell time of line-scanning confocal microscopy enables subcellular-level imaging of these nanomaterials while maintaining optical sectioning. The line-scanning approach thus enables microscopic imaging of this emerging class of contrast agents for preclinical studies, with the potential to be adapted for real-time in vivo imaging in the clinic. PMID:26603495

  18. Contrast-enhanced CT with a High-Affinity Cationic Contrast Agent for Imaging ex Vivo Bovine, Intact ex Vivo Rabbit, and in Vivo Rabbit Cartilage

    OpenAIRE

    Stewart, Rachel C.; Bansal, Prashant N.; Entezari, Vahid; Lusic, Hrvoje; Nazarian, Rosalynn M.; Snyder, Brian D.; Grinstaff, Mark W.

    2013-01-01

    The high affinity of a cationic iodinated contrast agent for cartilage provides better tissue visualization, easier segmentation, higher contrast-to-noise ratios, and longer usable imaging windows and requires a lower dose of injected contrast agent compared with an anionic contrast agent.

  19. Use of high concentration contrast media: principles and rationale--vascular district

    International Nuclear Information System (INIS)

    Fleischmann, Dominik.

    2003-01-01

    Optimal contrast medium delivery remains a crucial issue in CT angiography and it will become even more critical with continuously evolving, faster CT scanner technology. This review article first explains the fundamentals of arterial enhancement using mathematical models of early contrast medium dynamics. The relationship of contrast medium volume, injection flow rates and injection duration are explicitly illustrated. Next, current techniques of contrast medium application are reviewed, with particular attention to methods of accurate timing of the scanning delay (test-bolus and automated bolus triggering), tools for automated saline-flushing of the veins (double-syringe power injectors) and the use of high-concentration contrast medium. From there, rational CT angiographic injection protocols for a wide range of selectable acquisition times for 4-, 8- and 16-channel MDCT are proposed

  20. High-dose contrast-enhanced MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Koudriavtseva, T.; Pozzilli, C.; Di Biasi, C.; Iannilli, M.; Trasimeni, G.; Gasperini, C.; Argentino, C.; Gualdi, G.F.

    1996-01-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs

  1. High-dose contrast-enhanced MRI in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Koudriavtseva, T. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Pozzilli, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Di Biasi, C. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Iannilli, M. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Trasimeni, G. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Gasperini, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Argentino, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Gualdi, G.F. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy)

    1996-05-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs.

  2. Renal streaky artifact during contrast-enhanced abdominal and pelvic CT: Comparison of high versus low osmolality contrast media

    International Nuclear Information System (INIS)

    Kim, Dae Hong; Kim, Jong Chul; Lee, Chung Keun; Shin, Kyoung Suk

    1994-01-01

    Introduction of low osmolality contrast agent(LOCA) has allowed safer, more comfortable contrast-enhanced CT examination, but there has been significant increase in image degradation when evaluating the kidneys due to streaky artifact. The authors reviewed findings of contrast- enhanced abdominal and pelvic computed tomography(CT) to know the difference of renal streaky artifact between a high osmolality contrast agent (HOCA) and LOCA. This study included two hundred contrast-enhanced CT in 200 patients, 100 performed with HOCA(meglumine ioglicate, 150 ml) and 100 performed with LOCA (iopromide,150 ml). The severity of renal streaky artifact was compared between HOCA and LOCA groups. Of the scans performed with HOCA, 40 had no artifact, 52 had grade I artifact, 6 had grade II artifact, and 2 had grade III artifact. Of the scans preformed with LOCA, 23 had no artifact, 44 had grade I artifact, 29 had grade II artifact, and 4 had grade III artifact. There was significant difference in the degree of the streaky artifact depending upon the osmolality of the contrast media used(by χ 2 -test, P=.0001). The results of this study revealed a statistically significant increased incidence of artifacts and distortions of renal image with LOCA when compared with HOCA

  3. High-contrast imaging with an arbitrary aperture: Active compensation of aperture discontinuities

    International Nuclear Information System (INIS)

    Pueyo, Laurent; Norman, Colin

    2013-01-01

    We present a new method to achieve high-contrast images using segmented and/or on-axis telescopes. Our approach relies on using two sequential deformable mirrors (DMs) to compensate for the large amplitude excursions in the telescope aperture due to secondary support structures and/or segment gaps. In this configuration the parameter landscape of DM surfaces that yield high-contrast point-spread functions is not linear, and nonlinear methods are needed to find the true minimum in the optimization topology. We solve the highly nonlinear Monge-Ampere equation that is the fundamental equation describing the physics of phase-induced amplitude modulation. We determine the optimum configuration for our two sequential DM system and show that high-throughput and high-contrast solutions can be achieved using realistic surface deformations that are accessible using existing technologies. We name this process Active Compensation of Aperture Discontinuities (ACAD). We show that for geometries similar to the James Webb Space Telescope, ACAD can attain at least 10 –7 in contrast and an order of magnitude higher for both the future extremely large telescopes and on-axis architectures reminiscent of the Hubble Space Telescope. We show that the converging nonlinear mappings resulting from our DM shapes actually damp near-field diffraction artifacts in the vicinity of the discontinuities. Thus, ACAD actually lowers the chromatic ringing due to diffraction by segment gaps and struts while not amplifying the diffraction at the aperture edges beyond the Fresnel regime. This outer Fresnel ringing can be mitigated by properly designing the optical system. Consequently, ACAD is a true broadband solution to the problem of high-contrast imaging with segmented and/or on-axis apertures. We finally show that once the nonlinear solution is found, fine tuning with linear methods used in wavefront control can be applied to further contrast by another order of magnitude. Generally speaking, the

  4. High contrast laser marking of alumina

    Science.gov (United States)

    Penide, J.; Quintero, F.; Riveiro, A.; Fernández, A.; del Val, J.; Comesaña, R.; Lusquiños, F.; Pou, J.

    2015-05-01

    Alumina serves as raw material for a broad range of advanced ceramic products. These elements should usually be identified by some characters or symbols printed directly on them. In this sense, laser marking is an efficient, reliable and widely implemented process in industry. However, laser marking of alumina still leads to poor results since the process is not able to produce a dark mark, yielding bad contrast. In this paper, we present an experimental study on the process of marking alumina by three different lasers working in two wavelengths: 1064 nm (Near-infrared) and 532 nm (visible, green radiation). A colorimetric analysis has been carried out in order to compare the resulting marks and its contrast. The most suitable laser operating conditions were also defined and are reported here. Moreover, the physical process of marking by NIR lasers is discussed in detail. Field Emission Scanning Electron Microscopy, High Resolution Transmission Electron Microscopy and X-ray Photoelectron Spectroscopy were also employed to analyze the results. Finally, we propose an explanation for the differences of the coloration induced under different atmospheres and laser parameters. We concluded that the atmosphere is the key parameter, being the inert one the best choice to produce the darkest marks.

  5. Evaluation on correction factor for in-line X-ray phase contrast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Mingli; Huang, Zhifeng; Zhang, Li; Zhang, Ran [Tsinghua Univ., Beijing (China). Dept. of Engineering Physics; Ministry of Education, Beijing (China). Key Laboratory of Particle and Radiation Imaging; Yin, Hongxia; Liu, Yunfu; Wang, Zhenchang [Capital Medical Univ., Beijing (China). Medical Imaging Center; Xiao, Tiqiao [Chinese Academy of Sciences, Shanghai (China). Shanghai Inst. of Applied Physics

    2011-07-01

    X-ray in-line phase contrast computed tomography (CT) is an effective nondestructive tool, providing 3D distribution of the refractive index of weakly absorbing low-Z object with high resolution and image contrast, especially with high-brilliance third-generation synchrotron radiation sources. Modified Bronnikov's algorithm (MBA), one of the in-line phase contrast CT reconstruction algorithms, can reconstruct the refractive index distribution of a pure phase object with a single computed tomographic data set. The key idea of the MBA is to use a correction factor in the filter function to stabilize the behavior at low frequencies. In this paper, we evaluate the influences of the correction factor to the final reconstruction results of the absorption-phase-mixed objects with analytical simulation and actual experiments. The limitations of the MBA are discussed finally. (orig.)

  6. High-Fidelity Contrast Reaction Simulation Training: Performance Comparison of Faculty, Fellows, and Residents.

    Science.gov (United States)

    Pfeifer, Kyle; Staib, Lawrence; Arango, Jennifer; Kirsch, John; Arici, Mel; Kappus, Liana; Pahade, Jay

    2016-01-01

    Reactions to contrast material are uncommon in diagnostic radiology, and vary in clinical presentation from urticaria to life-threatening anaphylaxis. Prior studies have demonstrated a high error rate in contrast reaction management, with smaller studies using simulation demonstrating variable data on effectiveness. We sought to assess the effectiveness of high-fidelity simulation in teaching contrast reaction management for residents, fellows, and attendings. A 20-question multiple-choice test assessing contrast reaction knowledge, with Likert-scale questions assessing subjective comfort levels of management of contrast reactions, was created. Three simulation scenarios that represented a moderate reaction, a severe reaction, and a contrast reaction mimic were completed in a one-hour period in a simulation laboratory. All participants completed a pretest and a posttest at one month. A six-month delayed posttest was given, but was optional for all participants. A total of 150 radiologists participated (residents = 52; fellows = 24; faculty = 74) in the pretest and posttest; and 105 participants completed the delayed posttest (residents = 31; fellows = 17; faculty = 57). A statistically significant increase was found in the one-month posttest (P < .00001) and the six-month posttest scores (P < .00001) and Likert scores (P < .001) assessing comfort level in managing all contrast reactions, compared with the pretest. Test scores and comfort level for moderate and severe reactions significantly decreased at six months, compared with the one-month posttest (P < .05). High-fidelity simulation is an effective learning tool, allowing practice of "high-acuity" situation management in a nonthreatening environment; the simulation training resulted in significant improvement in test scores, as well as an increase in subjective comfort in management of reactions, across all levels of training. A six-month refresher course is suggested, to maintain knowledge and comfort level in

  7. Adobe Boxes: Locating Object Proposals Using Object Adobes.

    Science.gov (United States)

    Fang, Zhiwen; Cao, Zhiguo; Xiao, Yang; Zhu, Lei; Yuan, Junsong

    2016-09-01

    Despite the previous efforts of object proposals, the detection rates of the existing approaches are still not satisfactory enough. To address this, we propose Adobe Boxes to efficiently locate the potential objects with fewer proposals, in terms of searching the object adobes that are the salient object parts easy to be perceived. Because of the visual difference between the object and its surroundings, an object adobe obtained from the local region has a high probability to be a part of an object, which is capable of depicting the locative information of the proto-object. Our approach comprises of three main procedures. First, the coarse object proposals are acquired by employing randomly sampled windows. Then, based on local-contrast analysis, the object adobes are identified within the enlarged bounding boxes that correspond to the coarse proposals. The final object proposals are obtained by converging the bounding boxes to tightly surround the object adobes. Meanwhile, our object adobes can also refine the detection rate of most state-of-the-art methods as a refinement approach. The extensive experiments on four challenging datasets (PASCAL VOC2007, VOC2010, VOC2012, and ILSVRC2014) demonstrate that the detection rate of our approach generally outperforms the state-of-the-art methods, especially with relatively small number of proposals. The average time consumed on one image is about 48 ms, which nearly meets the real-time requirement.

  8. X-ray imaging with monochromatic synchrotron radiation. Fluorescent and phase-contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-05-01

    To obtain the high sensitive x-ray images of biomedical object, new x-ray imaging techniques using fluorescent x-ray and phase-contrast x-ray are being developed in Japan. Fluorescent x-ray CT can detect very small amounts of specific elements in the order of ppm at one pixel, whereas phase-contrast x-ray imaging with interferometer can detect minute differences of biological object. Here, our recent experimental results are presented. (author)

  9. A note on variational multiscale methods for high-contrast heterogeneous porous media flows with rough source terms

    KAUST Repository

    Calo, Victor M.

    2011-09-01

    In this short note, we discuss variational multiscale methods for solving porous media flows in high-contrast heterogeneous media with rough source terms. Our objective is to separate, as much as possible, subgrid effects induced by the media properties from those due to heterogeneous source terms. For this reason, enriched coarse spaces designed for high-contrast multiscale problems are used to represent the effects of heterogeneities of the media. Furthermore, rough source terms are captured via auxiliary correction equations that appear in the formulation of variational multiscale methods [23]. These auxiliary equations are localized and one can use additive or multiplicative constructions for the subgrid corrections as discussed in the current paper. Our preliminary numerical results show that one can capture the effects due to both spatial heterogeneities in the coefficients (such as permeability field) and source terms (e.g., due to singular well terms) in one iteration. We test the cases for both smooth source terms and rough source terms and show that with the multiplicative correction, the numerical approximations are more accurate compared to the additive correction. © 2010 Elsevier Ltd.

  10. Object-oriented wavefront correction in an asymmetric amplifying high-power laser system

    Science.gov (United States)

    Yang, Ying; Yuan, Qiang; Wang, Deen; Zhang, Xin; Dai, Wanjun; Hu, Dongxia; Xue, Qiao; Zhang, Xiaolu; Zhao, Junpu; Zeng, Fa; Wang, Shenzhen; Zhou, Wei; Zhu, Qihua; Zheng, Wanguo

    2018-05-01

    An object-oriented wavefront control method is proposed aiming for excellent near-field homogenization and far-field distribution in an asymmetric amplifying high-power laser system. By averaging the residual errors of the propagating beam, smaller pinholes could be employed on the spatial filters to improve the beam quality. With this wavefront correction system, the laser performance of the main amplifier system in the Shen Guang-III laser facility has been improved. The residual wavefront aberration at the position of each pinhole is below 2 µm (peak-to-valley). For each pinhole, 95% of the total laser energy is enclosed within a circle whose diameter is no more than six times the diffraction limit. At the output of the main laser system, the near-field modulation and contrast are 1.29% and 7.5%, respectively, and 95% of the 1ω (1053 nm) beam energy is contained within a 39.8 µrad circle (6.81 times the diffraction limit) under a laser fluence of 5.8 J cm-2. The measured 1ω focal spot size and near-field contrast are better than the design values of the Shen Guang-III laser facility.

  11. Ultra-High-Contrast Laser Acceleration of Relativistic Electrons in Solid Targets

    Science.gov (United States)

    Higginson, Drew Pitney

    The cone-guided fast ignition approach to Inertial Confinement Fusion requires laser-accelerated relativistic electrons to deposit kilojoules of energy within an imploded fuel core to initiate fusion burn. One obstacle to coupling electron energy into the core is the ablation of material, known as preplasma, by laser energy proceeding nanoseconds prior to the main pulse. This causes the laser-absorption surface to be pushed back hundreds of microns from the initial target surface; thus increasing the distance that electrons must travel to reach the imploded core. Previous experiments have shown an order of magnitude decrease in coupling into surrogate targets when intentionally increasing the amount of preplasma. Additionally, for electrons to deposit energy within the core, they should have kinetic energies on the order of a few MeV, as less energetic electrons will be stopped prior to the core and more energetic electrons will pass through the core without depositing much energy. Thus a quantitative understanding of the electron energy spectrum and how it responds to varied laser parameters is paramount for fast ignition. For the first time, this dissertation quantitatively investigates the acceleration of electrons using an ultra-high-contrast laser. Ultra-high-contrast lasers reduce the laser energy that reaches the target prior to the main pulse; drastically reducing the amount of preplasma. Experiments were performed in a cone-wire geometry relevant to fast ignition. These experiments irradiated the inner-tip of a Au cone with the laser and observed electrons that passed through a Cu wire attached to the outer-tip of the cone. The total emission of Kalpha x-rays is used as a diagnostic to infer the electron energy coupled into the wire. Imaging the x-ray emission allowed an effective path-length of electrons within the wire to be determined, which constrained the electron energy spectrum. Experiments were carried out on the ultra-high-contrast Trident laser

  12. Dark-field hyperlens for high-contrast sub-wavelength imaging

    DEFF Research Database (Denmark)

    Repän, Taavi; Zhukovsky, Sergei; Lavrinenko, Andrei

    2016-01-01

    By now superresolution imaging using hyperbolic metamaterial (HMM) structures – hyperlenses – has been demonstrated both theoretically and experimentally. The hyperlens operation relies on the fact that HMM allows propagation of waves with very large transverse wavevectors, which would be evanesc......By now superresolution imaging using hyperbolic metamaterial (HMM) structures – hyperlenses – has been demonstrated both theoretically and experimentally. The hyperlens operation relies on the fact that HMM allows propagation of waves with very large transverse wavevectors, which would...... be evanescent in common isotropic media (thus giving rise to the diffraction limit). However, nearly all hyperlenses proposed so far have been suitable only for very strong scatterers – such as holes in a metal film. When weaker scatterers, dielectric objects for example, are imaged then incident light forms...... a very strong background, and weak scatterers are not visible due to a poor contrast. We propose a so-called dark-field hyperlens, which would be suitable for imaging of weakly scattering objects. By designing parameters of the HMM, we managed to obtain its response in such way that the hyperlens...

  13. Super-nonlinear fluorescence microscopy for high-contrast deep tissue imaging

    Science.gov (United States)

    Wei, Lu; Zhu, Xinxin; Chen, Zhixing; Min, Wei

    2014-02-01

    Two-photon excited fluorescence microscopy (TPFM) offers the highest penetration depth with subcellular resolution in light microscopy, due to its unique advantage of nonlinear excitation. However, a fundamental imaging-depth limit, accompanied by a vanishing signal-to-background contrast, still exists for TPFM when imaging deep into scattering samples. Formally, the focusing depth, at which the in-focus signal and the out-of-focus background are equal to each other, is defined as the fundamental imaging-depth limit. To go beyond this imaging-depth limit of TPFM, we report a new class of super-nonlinear fluorescence microscopy for high-contrast deep tissue imaging, including multiphoton activation and imaging (MPAI) harnessing novel photo-activatable fluorophores, stimulated emission reduced fluorescence (SERF) microscopy by adding a weak laser beam for stimulated emission, and two-photon induced focal saturation imaging with preferential depletion of ground-state fluorophores at focus. The resulting image contrasts all exhibit a higher-order (third- or fourth- order) nonlinear signal dependence on laser intensity than that in the standard TPFM. Both the physical principles and the imaging demonstrations will be provided for each super-nonlinear microscopy. In all these techniques, the created super-nonlinearity significantly enhances the imaging contrast and concurrently extends the imaging depth-limit of TPFM. Conceptually different from conventional multiphoton processes mediated by virtual states, our strategy constitutes a new class of fluorescence microscopy where high-order nonlinearity is mediated by real population transfer.

  14. Thermoacoustic contrast of prostate cancer due to heating by very high frequency irradiation

    International Nuclear Information System (INIS)

    Patch, S K; Hull, D; Thomas, M; Jacobsohn, K; See, WA; Griep, SK

    2015-01-01

    Applying the thermoacoustic (TA) effect to diagnostic imaging was first proposed in the 1980s. The object under test is irradiated by high-power pulses of electromagnetic energy, which heat tissue and cause thermal expansion. Outgoing TA pressure pulses are detected by ultrasound transducers and reconstructed to provide images of the object. The TA contrast mechanism is strongly dependent upon the frequency of the irradiating electromagnetic pulse. When very high frequency (VHF) electromagnetic irradiation is utilized, TA signal production is driven by ionic content. Prostatic fluids contain high levels of ionic metabolites, including citrate, zinc, calcium, and magnesium. Healthy prostate glands produce more ionic metabolites than diseased glands. VHF pulses are therefore expected to generate stronger TA signal in healthy prostate glands than in diseased glands. A benchtop system for performing ex vivo TA computed tomography with VHF energy is described and images are presented. The system utilizes irradiation pulses of 700 ns duration exceeding 20 kW power. Reconstructions frequently visualize anatomic landmarks such as the urethra and verumontanum. TA reconstructions from three freshly excised human prostate glands with little, moderate, and severe cancerous involvement are compared with histology. TA signal strength is negatively correlated with percent cancerous involvement in this small sample size. For the 45 regions of interest analyzed, a reconstruction value of 0.4 mV provides 100% sensitivity but only 29% specificity. This sample size is far too small to draw sweeping conclusions, but the results warrant a larger volume study including comparison of TA images to the gold standard, histology. (paper)

  15. High-contrast imaging in the cloud with klipReduce and Findr

    Science.gov (United States)

    Haug-Baltzell, Asher; Males, Jared R.; Morzinski, Katie M.; Wu, Ya-Lin; Merchant, Nirav; Lyons, Eric; Close, Laird M.

    2016-08-01

    Astronomical data sets are growing ever larger, and the area of high contrast imaging of exoplanets is no exception. With the advent of fast, low-noise detectors operating at 10 to 1000 Hz, huge numbers of images can be taken during a single hours-long observation. High frame rates offer several advantages, such as improved registration, frame selection, and improved speckle calibration. However, advanced image processing algorithms are computationally challenging to apply. Here we describe a parallelized, cloud-based data reduction system developed for the Magellan Adaptive Optics VisAO camera, which is capable of rapidly exploring tens of thousands of parameter sets affecting the Karhunen-Loève image processing (KLIP) algorithm to produce high-quality direct images of exoplanets. We demonstrate these capabilities with a visible wavelength high contrast data set of a hydrogen-accreting brown dwarf companion.

  16. Reconstruction methods for phase-contrast tomography

    Energy Technology Data Exchange (ETDEWEB)

    Raven, C.

    1997-02-01

    Phase contrast imaging with coherent x-rays can be distinguished in outline imaging and holography, depending on the wavelength {lambda}, the object size d and the object-to-detector distance r. When r << d{sup 2}{lambda}, phase contrast occurs only in regions where the refractive index fastly changes, i.e. at interfaces and edges in the sample. With increasing object-to-detector distance we come in the area of holographic imaging. The image contrast outside the shadow region of the object is due to interference of the direct, undiffracted beam and a beam diffracted by the object, or, in terms of holography, the interference of a reference wave with the object wave. Both, outline imaging and holography, offer the possibility to obtain three dimensional information of the sample in conjunction with a tomographic technique. But the data treatment and the kind of information one can obtain from the reconstruction is different.

  17. High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography

    Science.gov (United States)

    Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; Yildirim, Ali Önder; Hertz, Hans M.

    2016-12-01

    X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.

  18. Laser-matter interaction at high intensity and high temporal contrast; Interaction laser matiere a haut flux et fort contraste temporel

    Energy Technology Data Exchange (ETDEWEB)

    Doumy, G

    2006-01-15

    The continuous progress in the development of laser installations has already lead to ultra-short pulses capable of achieving very high focalized intensities (I > 10{sup 18} W/cm{sup 2}). At these intensities, matter presents new non-linear behaviours, due to the fact that the electrons are accelerated to relativistic speeds. The experimental access to this interaction regime on solid targets has long been forbidden because of the presence, alongside the femtosecond pulse, of a pedestal (mainly due to the amplified spontaneous emission (ASE) which occurs in the laser chain) intense enough to modify the state of the target. In this thesis, we first characterized, both experimentally and theoretically, a device which allows an improvement of the temporal contrast of the pulse: the Plasma Mirror. It consists in adjusting the focusing of the pulse on a dielectric target, so that the pedestal is mainly transmitted, while the main pulse is reflected by the overcritical plasma that it forms at the surface. The implementation of such a device on the UHI 10 laser facility (CEA Saclay - 10 TW - 60 fs) then allowed us to study the interaction between ultra-intense, high contrast pulses with solid targets. In a first part, we managed to generate and characterize dense plasmas resulting directly from the interaction between the main pulse and very thin foils (100 nm). This characterization was realized by using an XUV source obtained by high order harmonics generation in a rare gas jet. In a second part, we studied experimentally the phenomenon of high order harmonics generation on solid targets, which is still badly understood, but could potentially lead to a new kind of energetic ultra-short XUV sources. (author)

  19. Preliminary study on X-ray phase contrast imaging using synchrotron radiation facility

    International Nuclear Information System (INIS)

    Xiong Zhuang; Wang Jianhua; Yu Yongqiang; Jiang Shiping; Chen Yang; Tian Yulian

    2006-01-01

    Objective: To study the methodology of X-ray phase contrast imaging using synchrotron radiation, and evaluate the quality of phase contrast images. Methods: Several experiments to obtain phase contrast images and absorption contrast images of various biological samples were conducted in Beijing Synchrotron Radiation Facility (BSRF), and then these images were interpreted to find out the difference between the two kinds of imaging methods. Results: Satisfactory phase contrast images of these various samples were obtained, and the quality of these images was superior to that obtained with absorption contrast imaging. The phase contrast formation is based on the phenomenon of fresnel diffraction which transforms phase shifts into intensity variations upon a simple act of free-space propagation, so it requires highly coherent X-rays and appropriate distance between sample and detector. This method of imaging is very useful in imaging of low-absorption objects or objects with little absorption variation, and its resolution is far higher than that of the conventional X-ray imaging. The photographs obtained showed very fine inner microstructure of the biological samples, and the smallest microstructure to be distinguished is within 30-40 μm. There is no doubt that phase contrast imaging has a practical applicability in medicine. Moreover, it improves greatly the efficiency and the resolution of the existing X-ray diagnostic techniques. Conclusions: X-ray phase contrast imaging can be performed with synchrotron radiation source and has some advantages over the conventional absorption contrast imaging. (authors)

  20. VIP: Vortex Image Processing Package for High-contrast Direct Imaging

    Science.gov (United States)

    Gomez Gonzalez, Carlos Alberto; Wertz, Olivier; Absil, Olivier; Christiaens, Valentin; Defrère, Denis; Mawet, Dimitri; Milli, Julien; Absil, Pierre-Antoine; Van Droogenbroeck, Marc; Cantalloube, Faustine; Hinz, Philip M.; Skemer, Andrew J.; Karlsson, Mikael; Surdej, Jean

    2017-07-01

    We present the Vortex Image Processing (VIP) library, a python package dedicated to astronomical high-contrast imaging. Our package relies on the extensive python stack of scientific libraries and aims to provide a flexible framework for high-contrast data and image processing. In this paper, we describe the capabilities of VIP related to processing image sequences acquired using the angular differential imaging (ADI) observing technique. VIP implements functionalities for building high-contrast data processing pipelines, encompassing pre- and post-processing algorithms, potential source position and flux estimation, and sensitivity curve generation. Among the reference point-spread function subtraction techniques for ADI post-processing, VIP includes several flavors of principal component analysis (PCA) based algorithms, such as annular PCA and incremental PCA algorithms capable of processing big datacubes (of several gigabytes) on a computer with limited memory. Also, we present a novel ADI algorithm based on non-negative matrix factorization, which comes from the same family of low-rank matrix approximations as PCA and provides fairly similar results. We showcase the ADI capabilities of the VIP library using a deep sequence on HR 8799 taken with the LBTI/LMIRCam and its recently commissioned L-band vortex coronagraph. Using VIP, we investigated the presence of additional companions around HR 8799 and did not find any significant additional point source beyond the four known planets. VIP is available at http://github.com/vortex-exoplanet/VIP and is accompanied with Jupyter notebook tutorials illustrating the main functionalities of the library.

  1. High and low osmolar contrast media: Who pays?

    International Nuclear Information System (INIS)

    Goethlin, J.H.

    1988-01-01

    To possibly avoid a case of contrast medium-related death in Norway every second or third year will mean a cost of many millions of dollars. It is not feasible without many patients being deprived of diagnostic possibilities. The solution is at present to use LOCM in high risk patients and small children until sufficient data (large, controlled series) can give a reliable answer to if or when LOCM should be used. (orig.)

  2. Dynamic Contrast-Enhanced Magnetic Resonance Enterography and Dynamic Contrast-Enhanced Ultrasonography in Crohn's Disease

    DEFF Research Database (Denmark)

    Wilkens, Rune; Peters, David A; Nielsen, Agnete Hedemann

    2017-01-01

    Purpose e Cross-sectional imaging methods are important for objective evaluationof small intestinal inflammationinCrohn'sdisease(CD).The primary aim was to compare relative parameters of intestinal perfusion between contrast-enhanced ultrasonography (CEUS) and dynamic contrast-enhanced magnetic...

  3. High-resolution breast tomography at high energy: a feasibility study of phase contrast imaging on a whole breast

    International Nuclear Information System (INIS)

    Sztrókay, A; Schlossbauer, T; Bamberg, F; Reiser, M F; Coan, P; Diemoz, P C; Brun, E; Bravin, A; Mayr, D

    2012-01-01

    Previous studies on phase contrast imaging (PCI) mammography have demonstrated an enhancement of breast morphology and cancerous tissue visualization compared to conventional imaging. We show here the first results of the PCI analyser-based imaging (ABI) in computed tomography (CT) mode on whole and large (>12 cm) tumour-bearing breast tissues. We demonstrate in this work the capability of the technique of working at high x-ray energies and producing high-contrast images of large and complex specimens. One entire breast of an 80-year-old woman with invasive ductal cancer was imaged using ABI-CT with monochromatic 70 keV x-rays and an area detector of 92×92 µm 2 pixel size. Sagittal slices were reconstructed from the acquired data, and compared to corresponding histological sections. Comparison with conventional absorption-based CT was also performed. Five blinded radiologists quantitatively evaluated the visual aspects of the ABI-CT images with respect to sharpness, soft tissue contrast, tissue boundaries and the discrimination of different structures/tissues. ABI-CT excellently depicted the entire 3D architecture of the breast volume by providing high-resolution and high-contrast images of the normal and cancerous breast tissues. These results are an important step in the evolution of PCI-CT towards its clinical implementation. (paper)

  4. High-resolution breast tomography at high energy: a feasibility study of phase contrast imaging on a whole breast

    Science.gov (United States)

    Sztrókay, A.; Diemoz, P. C.; Schlossbauer, T.; Brun, E.; Bamberg, F.; Mayr, D.; Reiser, M. F.; Bravin, A.; Coan, P.

    2012-05-01

    Previous studies on phase contrast imaging (PCI) mammography have demonstrated an enhancement of breast morphology and cancerous tissue visualization compared to conventional imaging. We show here the first results of the PCI analyser-based imaging (ABI) in computed tomography (CT) mode on whole and large (>12 cm) tumour-bearing breast tissues. We demonstrate in this work the capability of the technique of working at high x-ray energies and producing high-contrast images of large and complex specimens. One entire breast of an 80-year-old woman with invasive ductal cancer was imaged using ABI-CT with monochromatic 70 keV x-rays and an area detector of 92×92 µm2 pixel size. Sagittal slices were reconstructed from the acquired data, and compared to corresponding histological sections. Comparison with conventional absorption-based CT was also performed. Five blinded radiologists quantitatively evaluated the visual aspects of the ABI-CT images with respect to sharpness, soft tissue contrast, tissue boundaries and the discrimination of different structures/tissues. ABI-CT excellently depicted the entire 3D architecture of the breast volume by providing high-resolution and high-contrast images of the normal and cancerous breast tissues. These results are an important step in the evolution of PCI-CT towards its clinical implementation.

  5. Anisotropic contrast optical microscope.

    Science.gov (United States)

    Peev, D; Hofmann, T; Kananizadeh, N; Beeram, S; Rodriguez, E; Wimer, S; Rodenhausen, K B; Herzinger, C M; Kasputis, T; Pfaunmiller, E; Nguyen, A; Korlacki, R; Pannier, A; Li, Y; Schubert, E; Hage, D; Schubert, M

    2016-11-01

    An optical microscope is described that reveals contrast in the Mueller matrix images of a thin, transparent, or semi-transparent specimen located within an anisotropic object plane (anisotropic filter). The specimen changes the anisotropy of the filter and thereby produces contrast within the Mueller matrix images. Here we use an anisotropic filter composed of a semi-transparent, nanostructured thin film with sub-wavelength thickness placed within the object plane. The sample is illuminated as in common optical microscopy but the light is modulated in its polarization using combinations of linear polarizers and phase plate (compensator) to control and analyze the state of polarization. Direct generalized ellipsometry data analysis approaches permit extraction of fundamental Mueller matrix object plane images dispensing with the need of Fourier expansion methods. Generalized ellipsometry model approaches are used for quantitative image analyses. These images are obtained from sets of multiple images obtained under various polarizer, analyzer, and compensator settings. Up to 16 independent Mueller matrix images can be obtained, while our current setup is limited to 11 images normalized by the unpolarized intensity. We demonstrate the anisotropic contrast optical microscope by measuring lithographically defined micro-patterned anisotropic filters, and we quantify the adsorption of an organic self-assembled monolayer film onto the anisotropic filter. Comparison with an isotropic glass slide demonstrates the image enhancement obtained by our method over microscopy without the use of an anisotropic filter. In our current instrument, we estimate the limit of detection for organic volumetric mass within the object plane of ≈49 fg within ≈7 × 7 μm 2 object surface area. Compared to a quartz crystal microbalance with dissipation instrumentation, where contemporary limits require a total load of ≈500 pg for detection, the instrumentation demonstrated here improves

  6. High-resolution blood-pool-contrast-enhanced MR angiography in glioblastoma: tumor-associated neovascularization as a biomarker for patient survival. A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Puig, Josep; Blasco, Gerard; Remollo, Sebastian; Hernandez, David; Pedraza, Salvador [Hospital Universitari Dr Josep Trueta, Research Unit of Diagnostic Imaging Institute (IDI), Department of Radiology [Girona Biomedical Research Institute] IDIBGI, Girona (Spain); Daunis-i-Estadella, Josep; Mateu, Gloria [University of Girona, Department of Computer Science, Applied Mathematics and Statistics, Girona (Spain); Alberich-Bayarri, Angel [La Fe Polytechnics and University Hospital, Biomedical Imaging Research Group (GIBI230), La Fe Health Research Institute, Valencia (Spain); Essig, Marco [University of Manitoba, Department of Radiology, Winnipeg (Canada); Jain, Rajan [NYU School of Medicine, Division of Neuroradiology, Department of Radiology, New York, NY (United States); Puigdemont, Montserrat [Hospital Universitari Dr Josep Trueta, Catalan Institute of Oncology (ICO), Hospital Cancer Registry, Girona (Spain); Sanchez-Gonzalez, Javier [Philips Healthcare Iberica, Madrid (Spain); Wintermark, Max [Stanford University, Department of Radiology, Neuroradiology Division, Palo Alto, CA (United States)

    2016-01-15

    The objective of the study was to determine whether tumor-associated neovascularization on high-resolution gadofosveset-enhanced magnetic resonance angiography (MRA) is a useful biomarker for predicting survival in patients with newly diagnosed glioblastomas. Before treatment, 35 patients (25 men; mean age, 64 ± 14 years) with glioblastoma underwent MRI including first-pass dynamic susceptibility contrast (DSC) perfusion and post-contrast T1WI sequences with gadobutrol (0.1 mmol/kg) and, 48 h later, high-resolution MRA with gadofosveset (0.03 mmol/kg). Volumes of interest for contrast-enhancing lesion (CEL), non-CEL, and contralateral normal-appearing white matter were obtained, and DSC perfusion and DWI parameters were evaluated. Prognostic factors were assessed by Kaplan-Meier survival and Cox proportional hazards model. Eighteen (51.42 %) glioblastomas were hypervascular on high-resolution MRA. Hypervascular glioblastomas were associated with higher CEL volume and lower Karnofsky score. Median survival rates for patients with hypovascular and hypervascular glioblastomas treated with surgery, radiotherapy, and chemotherapy were 15 and 9.75 months, respectively (P < 0.001). Tumor-associated neovascularization was the best predictor of survival at 5.25 months (AUC = 0.794, 81.2 % sensitivity, 77.8 % specificity, 76.5 % positive predictive value, 82.4 % negative predictive value) and yielded the highest hazard ratio (P < 0.001). Tumor-associated neovascularization detected on high-resolution blood-pool-contrast-enhanced MRA of newly diagnosed glioblastoma seems to be a useful biomarker that correlates with worse survival. (orig.)

  7. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Saitama (Japan). Advanced Research Laboratory; Takeda, Tohoru; Itai, Yuji

    1995-12-01

    Phase-contrast X-ray computed tomography (CT) enabling the observation of biological soft tissues without contrast enhancement has been developed. The X-ray phase shift caused by an object is measured and input to a standard CT reconstruction algorithm. A thousand times increase in the image sensitivity to soft tissues is achieved compared with the conventional CT using absorption contrast. This is because the X-ray phase shift cross section of light elements is about a thousand times larger than the absorption cross section. The phase shift is detected using an X-ray interferometer and computer analyses of interference patterns. Experiments were performed using a synchrotron X-ray source. Excellent image sensitivity is demonstrated in the observation of cancerous rabbit liver. The CT images distinguish cancer lesion from normal liver tissue and, moreover, visualize the pathological condition in the lesion. Although the X-ray energy employed and the present observation area size are not suitable for medical applications as they are, phase-contrast X-ray CT is promising for investigating the internal structure of soft tissue which is almost transparent for X-rays. The high sensitivity also provides the advantage of reducing X-ray doses. (author).

  8. Global contrast based salient region detection

    KAUST Repository

    Cheng, Ming-Ming

    2011-08-25

    Reliable estimation of visual saliency allows appropriate processing of images without prior knowledge of their contents, and thus remains an important step in many computer vision tasks including image segmentation, object recognition, and adaptive compression. We propose a regional contrast based saliency extraction algorithm, which simultaneously evaluates global contrast differences and spatial coherence. The proposed algorithm is simple, efficient, and yields full resolution saliency maps. Our algorithm consistently outperformed existing saliency detection methods, yielding higher precision and better recall rates, when evaluated using one of the largest publicly available data sets. We also demonstrate how the extracted saliency map can be used to create high quality segmentation masks for subsequent image processing.

  9. Global contrast based salient region detection

    KAUST Repository

    Cheng, Ming-Ming; Zhang, Guo-Xin; Mitra, Niloy J.; Huang, Xiaolei; Hu, Shi-Min

    2011-01-01

    Reliable estimation of visual saliency allows appropriate processing of images without prior knowledge of their contents, and thus remains an important step in many computer vision tasks including image segmentation, object recognition, and adaptive compression. We propose a regional contrast based saliency extraction algorithm, which simultaneously evaluates global contrast differences and spatial coherence. The proposed algorithm is simple, efficient, and yields full resolution saliency maps. Our algorithm consistently outperformed existing saliency detection methods, yielding higher precision and better recall rates, when evaluated using one of the largest publicly available data sets. We also demonstrate how the extracted saliency map can be used to create high quality segmentation masks for subsequent image processing.

  10. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.; Morcos, Sameh K.

    2009-01-01

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) 40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  11. 1060-nm Tunable Monolithic High Index Contrast Subwavelength Grating VCSEL

    DEFF Research Database (Denmark)

    Ansbæk, Thor; Chung, Il-Sug; Semenova, Elizaveta

    2013-01-01

    We present the first tunable vertical-cavity surface-emitting laser (VCSEL) where the top distributed Bragg reflector has been completely substituted by an air-cladded high-index-contrast subwavelength grating (HCG) mirror. In this way, an extended cavity design can be realized by reducing...

  12. Novel Gd nanoparticles enhance vascular contrast for high-resolution magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Tot Bui

    2010-09-01

    Full Text Available Gadolinium (Gd, with its 7 unpaired electrons in 4f orbitals that provide a very large magnetic moment, is proven to be among the best agents for contrast enhanced MRI. Unfortunately, the most potent MR contrast agent based on Gd requires relatively high doses of Gd. The Gd-chelated to diethylene-triamine-penta-acetic acid (DTPA, or other derivatives (at 0.1 mmole/kg recommended dose, distribute broadly into tissues and clear through the kidney. These contrast agents carry the risk of Nephrogenic Systemic Fibrosis (NSF, particularly in kidney impaired subjects. Thus, Gd contrast agents that produce higher resolution images using a much lower Gd dose could address both imaging sensitivity and Gd safety.To determine whether a biocompatible lipid nanoparticle with surface bound Gd can improve MRI contrast sensitivity, we constructed Gd-lipid nanoparticles (Gd-LNP containing lipid bound DTPA and Gd. The Gd-LNP were intravenously administered to rats and MR images collected. We found that Gd in Gd-LNP produced a greater than 33-fold higher longitudinal (T(1 relaxivity, r(1, constant than the current FDA approved Gd-chelated contrast agents. Intravenous administration of these Gd-LNP at only 3% of the recommended clinical Gd dose produced MRI signal-to-noise ratios of greater than 300 in all vasculatures. Unlike current Gd contrast agents, these Gd-LNP stably retained Gd in normal vasculature, and are eliminated predominately through the biliary, instead of the renal system. Gd-LNP did not appear to accumulate in the liver or kidney, and was eliminated completely within 24 hrs.The novel Gd-nanoparticles provide high quality contrast enhanced vascular MRI at 97% reduced dose of Gd and do not rely on renal clearance. This new agent is likely to be suitable for patients exhibiting varying degrees of renal impairment. The simple and adaptive nanoparticle design could accommodate ligand or receptor coating for drug delivery optimization and in vivo drug

  13. Low incidence of nephropathy in surgical ICU patients receiving intravenous contrast : a retrospective analysis

    NARCIS (Netherlands)

    Haveman, Jan Willem; Gansevoort, Ron T.; Bongaerts, Alfons H. H.; Nijsten, Maarten W. N.

    Objective: Various studies have documented a markedly high incidence of contrast-induced nephropathy (CIN). Most of these studies were conducted in patients not in the ICU. In ICU patients intravenous contrast may be withheld for fear of CIN. We investigated the incidence of CIN in ICU patients.

  14. Ultra-High-Contrast Laser Acceleration of Relativistic Electrons in Solid Targets

    Energy Technology Data Exchange (ETDEWEB)

    Higginson, Drew Pitney [Univ. of California, San Diego, CA (United States)

    2013-01-01

    The cone-guided fast ignition approach to Inertial Con nement Fusion requires laser-accelerated relativistic electrons to deposit kilojoules of energy within an imploded fuel core to initiate fusion burn. One obstacle to coupling electron energy into the core is the ablation of material, known as preplasma, by laser energy proceeding nanoseconds prior to the main pulse. This causes the laser-absorption surface to be pushed back hundreds of microns from the initial target surface; thus increasing the distance that electrons must travel to reach the imploded core. Previous experiments have shown an order of magnitude decrease in coupling into surrogate targets when intentionally increasing the amount of preplasma. Additionally, for electrons to deposit energy within the core, they should have kinetic energies on the order of a few MeV, as less energetic electrons will be stopped prior to the core and more energetic electrons will pass through the core without depositing much energy. Thus a quantitative understanding of the electron energy spectrum and how it responds to varied laser parameters is paramount for fast ignition. For the rst time, this dissertation quantitatively investigates the acceleration of electrons using an ultra-high-contrast laser. Ultra-high-contrast lasers reduce the laser energy that reaches the target prior to the main pulse; drastically reducing the amount of preplasma. Experiments were performed in a cone-wire geometry relevant to fast ignition. These experiments irradiated the inner-tip of a Au cone with the laser and observed electrons that passed through a Cu wire attached to the outer-tip of the cone. The total emission of K x-rays is used as a diagnostic to infer the electron energy coupled into the wire. Imaging the x-ray emission allowed an e ective path-length of electrons within the wire to be determined, which constrained the electron energy spectrum. Experiments were carried out on the ultra-high-contrast Trident laser at Los

  15. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography.

    Science.gov (United States)

    Brun, E; Grandl, S; Sztrókay-Gaul, A; Barbone, G; Mittone, A; Gasilov, S; Bravin, A; Coan, P

    2014-11-01

    Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure's possible applications. A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  16. Use of high concentration contrast media (HCCM): principles and rationale--body CT

    International Nuclear Information System (INIS)

    Brink, James A.

    2003-01-01

    Numerous complex pharmacokinetic interrelationships affect the use of contrast media for computed tomography (CT) imaging. The volume, concentration, and rate of injection, all affect the degree of enhancement that is achieved with an injection of contrast material. In addition, the injection technique, whether the contrast is infused with a constant injection rate (uniphasic injection) or whether the rate is altered during the injection (multiphasic injection) also affect the magnitude and duration of contrast enhancement. In body CT imaging, the liver poses unique challenges in managing the use of intravenous contrast material because of its dual blood supply and the need to complete imaging before equilibrium occurs between the intravascular and extravascular compartments. The magnitude of hepatic enhancement that is ultimately achieved is related primarily to the amount of iodinated contrast material that accumulates in the extravascular space within the target organ, independent of the speed of the CT scanner. The key determinant of the onset of the equilibrium phase is the injection duration. Given that a high injection flow rate (4-5 ml/s) is desirable for arterial phase imaging, the injection duration is maintained with use of an appropriate contrast volume. Thus, modifications of total iodine dose are best done with alterations in contrast concentration. The magnitude of arterial enhancement that is achieved is related to both the concentration and rate of contrast administration. The speed of the scanner determines its ability to record image data during the most advantageous time period, the peak of arterial enhancement. Thus, rapid imaging is particularly advantageous for optimal contrast use in CT angiography as well as in multiphasic imaging of the parenchymal organs

  17. Depiction of normal gastrointestinal anatomy with MDCT: Comparison of low- and high-attenuation oral contrast media

    International Nuclear Information System (INIS)

    Erturk, Sukru Mehmet; Mortele, Koenraad J.; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G.; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R.

    2008-01-01

    Purpose: To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). Materials and methods: A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Results: Duodenal, jejunal and ileal distention (p < 0.05, <0.001, <0.001, respectively) and wall visualization (p < 0.05, <0.01, <0.05, respectively) scores with low-attenuation contrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (p < 0.05, <0.01, respectively) were significantly higher than those with high-attenuation contrast medium, for reader 2. Interobserver agreement was fair to good for both distention (κ-range: 0.41-0.74) and wall visualization (κ-range: 0.48-0.71). Conclusion: MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium

  18. Characterization of low-mass deformable mirrors and ASIC drivers for high-contrast imaging

    Science.gov (United States)

    Mejia Prada, Camilo; Yao, Li; Wu, Yuqian; Roberts, Lewis C.; Shelton, Chris; Wu, Xingtao

    2017-09-01

    The development of compact, high performance Deformable Mirrors (DMs) is one of the most important technological challenges for high-contrast imaging on space missions. Microscale Inc. has fabricated and characterized piezoelectric stack actuator deformable mirrors (PZT-DMs) and Application-Specific Integrated Circuit (ASIC) drivers for direct integration. The DM-ASIC system is designed to eliminate almost all cables, enabling a very compact optical system with low mass and low power consumption. We report on the optical tests used to evaluate the performance of the DM and ASIC units. We also compare the results to the requirements for space-based high-contrast imaging of exoplanets.

  19. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT--a pooled analysis of two randomized trials

    DEFF Research Database (Denmark)

    Thomsen, Henrik S; Morcos, Sameh K

    2009-01-01

    of the LOCM were also observed in patients with GFR contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM......The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients...... with glomerular filtration rate (GFR) contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients...

  20. The Nonlinear Statistics of High-contrast Patches in Natural Images

    DEFF Research Database (Denmark)

    Lee, Ann; Pedersen, Kim Steenstrup; Mumford, David

    2003-01-01

    described. In this study, we explore the space of data points representing the values of 3 × 3 high-contrast patches from optical and 3D range images. We find that the distribution of data is extremely sparse with the majority of the data points concentrated in clusters and non-linear low...

  1. Memory Performance for Everyday Motivational and Neutral Objects Is Dissociable from Attention

    Directory of Open Access Journals (Sweden)

    Judith Schomaker

    2017-06-01

    Full Text Available Episodic memory is typically better for items coupled with monetary reward or punishment during encoding. It is yet unclear whether memory is also enhanced for everyday objects with appetitive or aversive values learned through a lifetime of experience, and to what extent episodic memory enhancement for motivational and neutral items is attributable to attention. In a first experiment, we investigated attention to everyday motivational objects using eye-tracking during free-viewing and subsequently tested episodic memory using a remember/know procedure. Attention was directed more to aversive stimuli, as evidenced by longer viewing durations, whereas recollection was higher for both appetitive and aversive objects. In the second experiment, we manipulated the visual contrast of neutral objects through changes of contrast to further dissociate attention and memory encoding. While objects presented with high visual contrast were looked at longer, recollection was best for objects presented in unmodified, medium contrast. Generalized logistic mixed models on recollection performance showed that attention as measured by eye movements did not enhance subsequent memory, while motivational value (Experiment 1 and visual contrast (Experiment 2 had quadratic effects in opposite directions. Our findings suggest that an enhancement of incidental memory encoding for appetitive items can occur without an increase in attention and, vice versa, that enhanced attention towards salient neutral objects is not necessarily associated with memory improvement. Together, our results provide evidence for a double dissociation of attention and memory effects under certain conditions.

  2. Memory Performance for Everyday Motivational and Neutral Objects Is Dissociable from Attention

    Science.gov (United States)

    Schomaker, Judith; Wittmann, Bianca C.

    2017-01-01

    Episodic memory is typically better for items coupled with monetary reward or punishment during encoding. It is yet unclear whether memory is also enhanced for everyday objects with appetitive or aversive values learned through a lifetime of experience, and to what extent episodic memory enhancement for motivational and neutral items is attributable to attention. In a first experiment, we investigated attention to everyday motivational objects using eye-tracking during free-viewing and subsequently tested episodic memory using a remember/know procedure. Attention was directed more to aversive stimuli, as evidenced by longer viewing durations, whereas recollection was higher for both appetitive and aversive objects. In the second experiment, we manipulated the visual contrast of neutral objects through changes of contrast to further dissociate attention and memory encoding. While objects presented with high visual contrast were looked at longer, recollection was best for objects presented in unmodified, medium contrast. Generalized logistic mixed models on recollection performance showed that attention as measured by eye movements did not enhance subsequent memory, while motivational value (Experiment 1) and visual contrast (Experiment 2) had quadratic effects in opposite directions. Our findings suggest that an enhancement of incidental memory encoding for appetitive items can occur without an increase in attention and, vice versa, that enhanced attention towards salient neutral objects is not necessarily associated with memory improvement. Together, our results provide evidence for a double dissociation of attention and memory effects under certain conditions. PMID:28694774

  3. Memory Performance for Everyday Motivational and Neutral Objects Is Dissociable from Attention.

    Science.gov (United States)

    Schomaker, Judith; Wittmann, Bianca C

    2017-01-01

    Episodic memory is typically better for items coupled with monetary reward or punishment during encoding. It is yet unclear whether memory is also enhanced for everyday objects with appetitive or aversive values learned through a lifetime of experience, and to what extent episodic memory enhancement for motivational and neutral items is attributable to attention. In a first experiment, we investigated attention to everyday motivational objects using eye-tracking during free-viewing and subsequently tested episodic memory using a remember/know procedure. Attention was directed more to aversive stimuli, as evidenced by longer viewing durations, whereas recollection was higher for both appetitive and aversive objects. In the second experiment, we manipulated the visual contrast of neutral objects through changes of contrast to further dissociate attention and memory encoding. While objects presented with high visual contrast were looked at longer, recollection was best for objects presented in unmodified, medium contrast. Generalized logistic mixed models on recollection performance showed that attention as measured by eye movements did not enhance subsequent memory, while motivational value (Experiment 1) and visual contrast (Experiment 2) had quadratic effects in opposite directions. Our findings suggest that an enhancement of incidental memory encoding for appetitive items can occur without an increase in attention and, vice versa, that enhanced attention towards salient neutral objects is not necessarily associated with memory improvement. Together, our results provide evidence for a double dissociation of attention and memory effects under certain conditions.

  4. Breaking object correspondence across saccadic eye movements deteriorates object recognition

    Directory of Open Access Journals (Sweden)

    Christian H. Poth

    2015-12-01

    Full Text Available Visual perception is based on information processing during periods of eye fixations that are interrupted by fast saccadic eye movements. The ability to sample and relate information on task-relevant objects across fixations implies that correspondence between presaccadic and postsaccadic objects is established. Postsaccadic object information usually updates and overwrites information on the corresponding presaccadic object. The presaccadic object representation is then lost. In contrast, the presaccadic object is conserved when object correspondence is broken. This helps transsaccadic memory but it may impose attentional costs on object recognition. Therefore, we investigated how breaking object correspondence across the saccade affects postsaccadic object recognition. In Experiment 1, object correspondence was broken by a brief postsaccadic blank screen. Observers made a saccade to a peripheral object which was displaced during the saccade. This object reappeared either immediately after the saccade or after the blank screen. Within the postsaccadic object, a letter was briefly presented (terminated by a mask. Observers reported displacement direction and letter identity in different blocks. Breaking object correspondence by blanking improved displacement identification but deteriorated postsaccadic letter recognition. In Experiment 2, object correspondence was broken by changing the object’s contrast-polarity. There were no object displacements and observers only reported letter identity. Again, breaking object correspondence deteriorated postsaccadic letter recognition. These findings identify transsaccadic object correspondence as a key determinant of object recognition across the saccade. This is in line with the recent hypothesis that breaking object correspondence results in separate representations of presaccadic and postsaccadic objects which then compete for limited attentional processing resources (Schneider, 2013. Postsaccadic

  5. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brun, E., E-mail: emmanuel.brun@esrf.fr [European Synchrotron Radiation Facility (ESRF), Grenoble 380000, France and Department of Physics, Ludwig-Maximilians University, Garching 85748 (Germany); Grandl, S.; Sztrókay-Gaul, A.; Gasilov, S. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Barbone, G. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Mittone, A.; Coan, P. [Department of Physics, Ludwig-Maximilians University, Garching 85748, Germany and Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Bravin, A. [European Synchrotron Radiation Facility (ESRF), Grenoble 380000 (France)

    2014-11-01

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  6. High Energy Resolution Hyperspectral X-Ray Imaging for Low-Dose Contrast-Enhanced Digital Mammography.

    Science.gov (United States)

    Pani, Silvia; Saifuddin, Sarene C; Ferreira, Filipa I M; Henthorn, Nicholas; Seller, Paul; Sellin, Paul J; Stratmann, Philipp; Veale, Matthew C; Wilson, Matthew D; Cernik, Robert J

    2017-09-01

    Contrast-enhanced digital mammography (CEDM) is an alternative to conventional X-ray mammography for imaging dense breasts. However, conventional approaches to CEDM require a double exposure of the patient, implying higher dose, and risk of incorrect image registration due to motion artifacts. A novel approach is presented, based on hyperspectral imaging, where a detector combining positional and high-resolution spectral information (in this case based on Cadmium Telluride) is used. This allows simultaneous acquisition of the two images required for CEDM. The approach was tested on a custom breast-equivalent phantom containing iodinated contrast agent (Niopam 150®). Two algorithms were used to obtain images of the contrast agent distribution: K-edge subtraction (KES), providing images of the distribution of the contrast agent with the background structures removed, and a dual-energy (DE) algorithm, providing an iodine-equivalent image and a water-equivalent image. The high energy resolution of the detector allowed the selection of two close-by energies, maximising the signal in KES images, and enhancing the visibility of details with the low surface concentration of contrast agent. DE performed consistently better than KES in terms of contrast-to-noise ratio of the details; moreover, it allowed a correct reconstruction of the surface concentration of the contrast agent in the iodine image. Comparison with CEDM with a conventional detector proved the superior performance of hyperspectral CEDM in terms of the image quality/dose tradeoff.

  7. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [University of Copenhagen, Department of Diagnostic Radiology, Copenhagen University Hospital Herlev, and Department of Diagnostic Sciences, Faculty of Health Sciences, Herlev (Denmark); Morcos, Sameh K. [University of Sheffield, Department of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom)

    2009-04-15

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) <60 ml/min undergoing contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients with moderate-to-severe renal failure received a similar IV contrast dose (40 gI). Serum creatinine (SCr) was measured at screening, baseline and 48-72 {+-} 6 h after the MDCT examination. Primary CIN outcome was an increase in SCr {>=}0.5 mg/dl ({>=}44.2 {mu}mol/l) from baseline. The CIN rates were 2.3% in the total population, 0.6% when GFR >40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  8. Moderate Contrast in the Evaluation of Paintings Is Liked More but Remembered Less than High Contrast

    Directory of Open Access Journals (Sweden)

    Katinka Dijkstra

    2017-09-01

    Full Text Available Many visual aspects of paintings, as well as exposure to art and cultural norms, contribute to the aesthetic evaluation of paintings. The current study looked at heightened visual contrast as an important factor in the appreciation of paintings. Participants evaluated abstract digitized paintings that were manipulated in contrast for an appreciation task and were later presented with these paintings in a memory task. The results indicated that for art appreciation, a moderate increase in contrast resulted in the highest appreciation for paintings whereas recognition memory was better for paintings with a higher increase in contrast. These results replicate earlier findings with regard to the role of contrast in aesthetic perception and extend these findings by demonstrating a surprising different effect of contrast manipulation for recognition memory. Confidence with which memory decisions were made was in line with art appreciation decisions not memory performance.

  9. Effects of contrast improvement on high voltage rectification type of x-ray diagnostic apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hoo Min; Yoon, Joon [Dept. of Radiological technology, Dongnam Health University, Suwon (Korea, Republic of); Kim, Hyun Ju [Dept. of Radiology, Soonchunhyang University Hospital Buchen, Bucheon (Korea, Republic of)

    2014-09-15

    The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

  10. Effects of contrast improvement on high voltage rectification type of x-ray diagnostic apparatus

    International Nuclear Information System (INIS)

    Lee, Hoo Min; Yoon, Joon; Kim, Hyun Ju

    2014-01-01

    The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier

  11. Depiction of normal gastrointestinal anatomy with MDCT: comparison of low- and high-attenuation oral contrast media.

    Science.gov (United States)

    Erturk, Sukru Mehmet; Mortelé, Koenraad J; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R

    2008-04-01

    To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Duodenal, jejunal and ileal distention (pcontrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (pcontrast medium, for reader 2. Interobserver agreement was fair to good for both distention (kappa-range: 0.41-0.74) and wall visualization (kappa-range: 0.48-0.71). MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium.

  12. Objective task-based assessment of low-contrast detectability in iterative reconstruction

    International Nuclear Information System (INIS)

    Racine, Damien; Ott, Julien G.; Ba, Alexandre; Ryckx, Nick; Bochud, Francois O.; Verdun, Francis R.

    2016-01-01

    Evaluating image quality by using receiver operating characteristic studies is time consuming and difficult to implement. This work assesses a new iterative algorithm using a channelised Hotelling observer (CHO). For this purpose, an anthropomorphic abdomen phantom with spheres of various sizes and contrasts was scanned at 3 volume computed tomography dose index (CTDI vol ) levels on a GE Revolution CT. Images were reconstructed using the iterative reconstruction method adaptive statistical iterative reconstruction-V (ASIR-V) at ASIR-V 0, 50 and 70 % and assessed by applying a CHO with dense difference of Gaussian and internal noise. Both CHO and human observers (HO) were compared based on a four-alternative forced-choice experiment, using the percentage correct as a figure of merit. The results showed accordance between CHO and HO. Moreover, an improvement in the low-contrast detection was observed when switching from ASIR-V 0 to 50 %. The results underpin the finding that ASIR-V allows dose reduction. (authors)

  13. Specular Reflectivity and Hot-Electron Generation in High-Contrast Relativistic Laser-Plasma Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, Gregory Elijah [The Ohio State Univ., Columbus, OH (United States)

    2013-01-01

    Ultra-intense laser (> 1018 W/cm2) interactions with matter are capable of producing relativistic electrons which have a variety of applications in state-of-the-art scientific and medical research conducted at universities and national laboratories across the world. Control of various aspects of these hot-electron distributions is highly desired to optimize a particular outcome. Hot-electron generation in low-contrast interactions, where significant amounts of under-dense pre-plasma are present, can be plagued by highly non-linear relativistic laser-plasma instabilities and quasi-static magnetic field generation, often resulting in less than desirable and predictable electron source characteristics. High-contrast interactions offer more controlled interactions but often at the cost of overall lower coupling and increased sensitivity to initial target conditions. An experiment studying the differences in hot-electron generation between high and low-contrast pulse interactions with solid density targets was performed on the Titan laser platform at the Jupiter Laser Facility at Lawrence Livermore National Laboratory in Livermore, CA. To date, these hot-electrons generated in the laboratory are not directly observable at the source of the interaction. Instead, indirect studies are performed using state-of-the-art simulations, constrained by the various experimental measurements. These measurements, more-often-than-not, rely on secondary processes generated by the transport of these electrons through the solid density materials which can susceptible to a variety instabilities and target material/geometry effects. Although often neglected in these types of studies, the specularly reflected light can provide invaluable insight as it is directly influenced by the interaction. In this thesis, I address the use of (personally obtained) experimental specular reflectivity measurements to indirectly study hot-electron generation in the context of high-contrast, relativistic

  14. THE TRENDS HIGH-CONTRAST IMAGING SURVEY. III. A FAINT WHITE DWARF COMPANION ORBITING HD 114174

    International Nuclear Information System (INIS)

    Crepp, Justin R.; Johnson, John Asher; Howard, Andrew W.; Marcy, Geoffrey W.; Gianninas, Alexandros; Kilic, Mukremin; Wright, Jason T.

    2013-01-01

    The nearby Sun-like star HD 114174 exhibits a strong and persistent Doppler acceleration indicating the presence of an unseen distant companion. We have acquired high-contrast imaging observations of this star using NIRC2 at Keck and report the direct detection of the body responsible for causing the ''trend''. HD 114174 B has a projected separation of 692 ± 9 mas (18.1 AU) and is 10.75 ± 0.12 mag (contrast of 5 × 10 –5 ) fainter than its host in the K-band, requiring aggressive point-spread function subtraction to identify. Our astrometric time baseline of 1.4 yr demonstrates physical association through common proper motion. We find that the companion has absolute magnitude, M J = 13.97 ± 0.11, and colors, J – K = 0.12 ± 0.16 mag. These characteristics are consistent with an ≈T3 dwarf, initially leading us to believe that HD 114174 B was a substellar object. However, a dynamical analysis that combines radial velocity measurements with available imaging data indicates a minimum mass of 0.260 ± 0.010 M ☉ . We conclude that HD 114174 B must be a white dwarf. Assuming a hydrogen-rich composition, atmospheric and evolutionary model fits yield an effective temperature T eff = 8200 ± 4000 K, surface gravity log g = 8.90 ± 0.02, and cooling age of t c ≈ 3.4 Gyr, which is consistent with the 4.7 +2.3 -2.6 Gyr host star isochronal age estimate. HD 114174 B is a benchmark object located only 26.14 ± 0.37 pc from the Sun. It may be studied at a level of detail comparable to Sirius and Procyon, and used to understand the link between the mass of white dwarf remnants with that of their progenitors

  15. THE TRENDS HIGH-CONTRAST IMAGING SURVEY. III. A FAINT WHITE DWARF COMPANION ORBITING HD 114174

    Energy Technology Data Exchange (ETDEWEB)

    Crepp, Justin R. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Johnson, John Asher [Department of Planetary Science, California Institute of Technology, 1200 E. California Blvd., Pasadena, CA 91125 (United States); Howard, Andrew W. [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States); Marcy, Geoffrey W. [Department of Astronomy, University of California, Berkeley, CA 94720 (United States); Gianninas, Alexandros; Kilic, Mukremin [Department of Physics and Astronomy, University of Oklahoma, Norman, OK 73019 (United States); Wright, Jason T., E-mail: jcrepp@nd.edu [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States)

    2013-09-01

    The nearby Sun-like star HD 114174 exhibits a strong and persistent Doppler acceleration indicating the presence of an unseen distant companion. We have acquired high-contrast imaging observations of this star using NIRC2 at Keck and report the direct detection of the body responsible for causing the ''trend''. HD 114174 B has a projected separation of 692 {+-} 9 mas (18.1 AU) and is 10.75 {+-} 0.12 mag (contrast of 5 Multiplication-Sign 10{sup -5}) fainter than its host in the K-band, requiring aggressive point-spread function subtraction to identify. Our astrometric time baseline of 1.4 yr demonstrates physical association through common proper motion. We find that the companion has absolute magnitude, M{sub J} = 13.97 {+-} 0.11, and colors, J - K = 0.12 {+-} 0.16 mag. These characteristics are consistent with an Almost-Equal-To T3 dwarf, initially leading us to believe that HD 114174 B was a substellar object. However, a dynamical analysis that combines radial velocity measurements with available imaging data indicates a minimum mass of 0.260 {+-} 0.010 M{sub Sun }. We conclude that HD 114174 B must be a white dwarf. Assuming a hydrogen-rich composition, atmospheric and evolutionary model fits yield an effective temperature T{sub eff} = 8200 {+-} 4000 K, surface gravity log g = 8.90 {+-} 0.02, and cooling age of t{sub c} Almost-Equal-To 3.4 Gyr, which is consistent with the 4.7{sup +2.3}{sub -2.6} Gyr host star isochronal age estimate. HD 114174 B is a benchmark object located only 26.14 {+-} 0.37 pc from the Sun. It may be studied at a level of detail comparable to Sirius and Procyon, and used to understand the link between the mass of white dwarf remnants with that of their progenitors.

  16. Object-Oriented Programming in High Schools the Turing Way.

    Science.gov (United States)

    Holt, Richard C.

    This paper proposes an approach to introducing object-oriented concepts to high school computer science students using the Object-Oriented Turing (OOT) language. Students can learn about basic object-oriented (OO) principles such as classes and inheritance by using and expanding a collection of classes that draw pictures like circles and happy…

  17. Differentiating between Central Nervous System Lymphoma and High-grade Glioma Using Dynamic Susceptibility Contrast and Dynamic Contrast-enhanced MR Imaging with Histogram Analysis.

    Science.gov (United States)

    Murayama, Kazuhiro; Nishiyama, Yuya; Hirose, Yuichi; Abe, Masato; Ohyu, Shigeharu; Ninomiya, Ayako; Fukuba, Takashi; Katada, Kazuhiro; Toyama, Hiroshi

    2018-01-10

    We evaluated the diagnostic performance of histogram analysis of data from a combination of dynamic susceptibility contrast (DSC)-MRI and dynamic contrast-enhanced (DCE)-MRI for quantitative differentiation between central nervous system lymphoma (CNSL) and high-grade glioma (HGG), with the aim of identifying useful perfusion parameters as objective radiological markers for differentiating between them. Eight lesions with CNSLs and 15 with HGGs who underwent MRI examination, including DCE and DSC-MRI, were enrolled in our retrospective study. DSC-MRI provides a corrected cerebral blood volume (cCBV), and DCE-MRI provides a volume transfer coefficient (K trans ) for transfer from plasma to the extravascular extracellular space. K trans and cCBV were measured from a round region-of-interest in the slice of maximum size on the contrast-enhanced lesion. The differences in t values between CNSL and HGG for determining the most appropriate percentile of K trans and cCBV were investigated. The differences in K trans , cCBV, and K trans /cCBV between CNSL and HGG were investigated using histogram analysis. Receiver operating characteristic (ROC) analysis of K trans , cCBV, and K trans /cCBV ratio was performed. The 30 th percentile (C30) in K trans and 80 th percentile (C80) in cCBV were the most appropriate percentiles for distinguishing between CNSL and HGG from the differences in t values. CNSL showed significantly lower C80 cCBV, significantly higher C30 K trans , and significantly higher C30 K trans /C80 cCBV than those of HGG. In ROC analysis, C30 K trans /C80 cCBV had the best discriminative value for differentiating between CNSL and HGG as compared to C30 K trans or C80 cCBV. The combination of K trans by DCE-MRI and cCBV by DSC-MRI was found to reveal the characteristics of vascularity and permeability of a lesion more precisely than either K trans or cCBV alone. Histogram analysis of these vascular microenvironments enabled quantitative differentiation between

  18. Mode decomposition methods for flows in high-contrast porous media. Global-local approach

    KAUST Repository

    Ghommem, Mehdi; Presho, Michael; Calo, Victor M.; Efendiev, Yalchin R.

    2013-01-01

    In this paper, we combine concepts of the generalized multiscale finite element method (GMsFEM) and mode decomposition methods to construct a robust global-local approach for model reduction of flows in high-contrast porous media. This is achieved by implementing Proper Orthogonal Decomposition (POD) and Dynamic Mode Decomposition (DMD) techniques on a coarse grid computed using GMsFEM. The resulting reduced-order approach enables a significant reduction in the flow problem size while accurately capturing the behavior of fully-resolved solutions. We consider a variety of high-contrast coefficients and present the corresponding numerical results to illustrate the effectiveness of the proposed technique. This paper is a continuation of our work presented in Ghommem et al. (2013) [1] where we examine the applicability of POD and DMD to derive simplified and reliable representations of flows in high-contrast porous media on fully resolved models. In the current paper, we discuss how these global model reduction approaches can be combined with local techniques to speed-up the simulations. The speed-up is due to inexpensive, while sufficiently accurate, computations of global snapshots. © 2013 Elsevier Inc.

  19. Mode decomposition methods for flows in high-contrast porous media. Global-local approach

    KAUST Repository

    Ghommem, Mehdi

    2013-11-01

    In this paper, we combine concepts of the generalized multiscale finite element method (GMsFEM) and mode decomposition methods to construct a robust global-local approach for model reduction of flows in high-contrast porous media. This is achieved by implementing Proper Orthogonal Decomposition (POD) and Dynamic Mode Decomposition (DMD) techniques on a coarse grid computed using GMsFEM. The resulting reduced-order approach enables a significant reduction in the flow problem size while accurately capturing the behavior of fully-resolved solutions. We consider a variety of high-contrast coefficients and present the corresponding numerical results to illustrate the effectiveness of the proposed technique. This paper is a continuation of our work presented in Ghommem et al. (2013) [1] where we examine the applicability of POD and DMD to derive simplified and reliable representations of flows in high-contrast porous media on fully resolved models. In the current paper, we discuss how these global model reduction approaches can be combined with local techniques to speed-up the simulations. The speed-up is due to inexpensive, while sufficiently accurate, computations of global snapshots. © 2013 Elsevier Inc.

  20. Asymmetric-detection time-stretch optical microscopy (ATOM) for ultrafast high-contrast cellular imaging in flow

    Science.gov (United States)

    Wong, Terence T. W.; Lau, Andy K. S.; Ho, Kenneth K. Y.; Tang, Matthew Y. H.; Robles, Joseph D. F.; Wei, Xiaoming; Chan, Antony C. S.; Tang, Anson H. L.; Lam, Edmund Y.; Wong, Kenneth K. Y.; Chan, Godfrey C. F.; Shum, Ho Cheung; Tsia, Kevin K.

    2014-01-01

    Accelerating imaging speed in optical microscopy is often realized at the expense of image contrast, image resolution, and detection sensitivity – a common predicament for advancing high-speed and high-throughput cellular imaging. We here demonstrate a new imaging approach, called asymmetric-detection time-stretch optical microscopy (ATOM), which can deliver ultrafast label-free high-contrast flow imaging with well delineated cellular morphological resolution and in-line optical image amplification to overcome the compromised imaging sensitivity at high speed. We show that ATOM can separately reveal the enhanced phase-gradient and absorption contrast in microfluidic live-cell imaging at a flow speed as high as ~10 m/s, corresponding to an imaging throughput of ~100,000 cells/sec. ATOM could thus be the enabling platform to meet the pressing need for intercalating optical microscopy in cellular assay, e.g. imaging flow cytometry – permitting high-throughput access to the morphological information of the individual cells simultaneously with a multitude of parameters obtained in the standard assay. PMID:24413677

  1. [Comparison of diagnostic quality in hysterosalpingography between iodinated non-ionic contrast media with low and high osmolarity].

    Science.gov (United States)

    Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V

    Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.

  2. Control of objects with a high degree of freedom

    OpenAIRE

    Wang, He

    2012-01-01

    In this thesis, I present novel strategies for controlling objects with high degrees of freedom for the purpose of robotic control and computer animation, including articulated objects such as human bodies or robots and deformable objects such as ropes and cloth. Such control is required for common daily movements such as folding arms, tying ropes, wrapping objects and putting on clothes. Although there is demand in computer graphics and animation for generating such scenes, li...

  3. Tunable Resonant-Cavity-Enhanced Photodetector with Double High-Index-Contrast Grating Mirrors

    DEFF Research Database (Denmark)

    Learkthanakhachon, Supannee; Yvind, Kresten; Chung, Il-Sug

    2013-01-01

    In this paper, we propose a broadband-tunable resonant-cavity-enhanced photodetector (RCE-PD) structure with double high-index-contrast grating (HCG) mirrors and numerically investigate its characteristics. The detector is designed to operate at 1550-nm wavelength. The detector structure consists....... Furthermore, the fact that it can be fabricated on a silicon platform offers us a possibility of integration with electronics.......In this paper, we propose a broadband-tunable resonant-cavity-enhanced photodetector (RCE-PD) structure with double high-index-contrast grating (HCG) mirrors and numerically investigate its characteristics. The detector is designed to operate at 1550-nm wavelength. The detector structure consists...... of a top InP HCG mirror, a p-i-n photodiode embedding multiple quantum wells, and a Si HCG mirror formed in the Si layer of a silicon-on-insulator wafer. The detection wavelength can be changed by moving the top InP HCG mirror suspended in the air. High reflectivity and small penetration length of HCGs...

  4. PHASE QUANTIZATION STUDY OF SPATIAL LIGHT MODULATOR FOR EXTREME HIGH-CONTRAST IMAGING

    Energy Technology Data Exchange (ETDEWEB)

    Dou, Jiangpei; Ren, Deqing, E-mail: jpdou@niaot.ac.cn, E-mail: jiangpeidou@gmail.com [Physics and Astronomy Department, California State University Northridge, 18111 Nordhoff Street, Northridge, CA 91330 (United States)

    2016-11-20

    Direct imaging of exoplanets by reflected starlight is extremely challenging due to the large luminosity ratio to the primary star. Wave-front control is a critical technique to attenuate the speckle noise in order to achieve an extremely high contrast. We present a phase quantization study of a spatial light modulator (SLM) for wave-front control to meet the contrast requirement of detection of a terrestrial planet in the habitable zone of a solar-type star. We perform the numerical simulation by employing the SLM with different phase accuracy and actuator numbers, which are related to the achievable contrast. We use an optimization algorithm to solve the quantization problems that is matched to the controllable phase step of the SLM. Two optical configurations are discussed with the SLM located before and after the coronagraph focal plane mask. The simulation result has constrained the specification for SLM phase accuracy in the above two optical configurations, which gives us a phase accuracy of 0.4/1000 and 1/1000 waves to achieve a contrast of 10{sup -10}. Finally, we have demonstrated that an SLM with more actuators can deliver a competitive contrast performance on the order of 10{sup -10} in comparison to that by using a deformable mirror.

  5. Design and Implementation of High-Performance GIS Dynamic Objects Rendering Engine

    Science.gov (United States)

    Zhong, Y.; Wang, S.; Li, R.; Yun, W.; Song, G.

    2017-12-01

    Spatio-temporal dynamic visualization is more vivid than static visualization. It important to use dynamic visualization techniques to reveal the variation process and trend vividly and comprehensively for the geographical phenomenon. To deal with challenges caused by dynamic visualization of both 2D and 3D spatial dynamic targets, especially for different spatial data types require high-performance GIS dynamic objects rendering engine. The main approach for improving the rendering engine with vast dynamic targets relies on key technologies of high-performance GIS, including memory computing, parallel computing, GPU computing and high-performance algorisms. In this study, high-performance GIS dynamic objects rendering engine is designed and implemented for solving the problem based on hybrid accelerative techniques. The high-performance GIS rendering engine contains GPU computing, OpenGL technology, and high-performance algorism with the advantage of 64-bit memory computing. It processes 2D, 3D dynamic target data efficiently and runs smoothly with vast dynamic target data. The prototype system of high-performance GIS dynamic objects rendering engine is developed based SuperMap GIS iObjects. The experiments are designed for large-scale spatial data visualization, the results showed that the high-performance GIS dynamic objects rendering engine have the advantage of high performance. Rendering two-dimensional and three-dimensional dynamic objects achieve 20 times faster on GPU than on CPU.

  6. Analyser-based phase contrast image reconstruction using geometrical optics.

    Science.gov (United States)

    Kitchen, M J; Pavlov, K M; Siu, K K W; Menk, R H; Tromba, G; Lewis, R A

    2007-07-21

    Analyser-based phase contrast imaging can provide radiographs of exceptional contrast at high resolution (geometrical optics are satisfied. Analytical phase retrieval can be performed by fitting the analyser rocking curve with a symmetric Pearson type VII function. The Pearson VII function provided at least a 10% better fit to experimentally measured rocking curves than linear or Gaussian functions. A test phantom, a hollow nylon cylinder, was imaged at 20 keV using a Si(1 1 1) analyser at the ELETTRA synchrotron radiation facility. Our phase retrieval method yielded a more accurate object reconstruction than methods based on a linear fit to the rocking curve. Where reconstructions failed to map expected values, calculations of the Takagi number permitted distinction between the violation of the geometrical optics conditions and the failure of curve fitting procedures. The need for synchronized object/detector translation stages was removed by using a large, divergent beam and imaging the object in segments. Our image acquisition and reconstruction procedure enables quantitative phase retrieval for systems with a divergent source and accounts for imperfections in the analyser.

  7. High ambient contrast ratio OLED and QLED without a circular polarizer

    International Nuclear Information System (INIS)

    Tan, Guanjun; Zhu, Ruidong; Luo, Zhenyue; Wu, Shin-Tson; Tsai, Yi-Shou; Lee, Kuo-Chang; Lee, Yuh-Zheng

    2016-01-01

    A high ambient contrast ratio display device using a transparent organic light emitting diode (OLED) or transparent quantum-dot light-emitting diode (QLED) with embedded multilayered structure and absorber is proposed and its performance is simulated. With the help of multilayered structure, the device structure allows almost all ambient light to get through the display device and be absorbed by the absorber. Because the reflected ambient light is greatly reduced, the ambient contrast ratio of the display system is improved significantly. Meanwhile, the multilayered structure helps to lower the effective refractive index, which in turn improves the out-coupling efficiency of the display system. Potential applications for sunlight readable flexible and rollable displays are emphasized. (paper)

  8. Fixations on objects in natural scenes: dissociating importance from salience

    Directory of Open Access Journals (Sweden)

    Bernard Marius e’t Hart

    2013-07-01

    Full Text Available The relation of selective attention to understanding of natural scenes has been subject to intense behavioral research and computational modeling, and gaze is often used as a proxy for such attention. The probability of an image region to be fixated typically correlates with its contrast. However, this relation does not imply a causal role of contrast. Rather, contrast may relate to an object’s importance for a scene, which in turn drives attention. Here we operationalize importance by the probability that an observer names the object as characteristic for a scene. We modify luminance contrast of either a frequently named (common/important or a rarely named (rare/unimportant object, track the observers’ eye movements during scene viewing and ask them to provide keywords describing the scene immediately after.When no object is modified relative to the background, important objects draw more fixations than unimportant ones. Increases of contrast make an object more likely to be fixated, irrespective of whether it was important for the original scene, while decreases in contrast have little effect on fixations. Any contrast modification makes originally unimportant objects more important for the scene. Finally, important objects are fixated more centrally than unimportant objects, irrespective of contrast.Our data suggest a dissociation between object importance (relevance for the scene and salience (relevance for attention. If an object obeys natural scene statistics, important objects are also salient. However, when natural scene statistics are violated, importance and salience are differentially affected. Object salience is modulated by the expectation about object properties (e.g., formed by context or gist, and importance by the violation of such expectations. In addition, the dependence of fixated locations within an object on the object’s importance suggests an analogy to the effects of word frequency on landing positions in reading.

  9. Synthesis of optical holograms of rotating objects

    International Nuclear Information System (INIS)

    Bogdanova, T.V.; Titar', V.P.; Tomchuk, E.Ya.

    1998-01-01

    A method of synthesis of rotating objects is analyzed and its advantages over the previously known methods and restrictions caused by the nonlinear character of motion of objects being studied are determined. Numerical simulation is used to study properties of synthesized holograms and the images reconstructed with their help. The resolving power of synthesized holograms is determined. The pulsed response of the system used for the synthesis of rotating objects is studied and its isoplanar sections are determined. It is shown that in the optical range, in contrast to the radio-frequency range, one can synthesize holograms and reconstruct visual images not only of rotating objects, but of vibrating objects as well. For small angles of object rotation (0.0025 rad), an image with a high resolution power (0.0004 m) can be obtained

  10. Safety of contrast media. Focus on contrast-induced nephropathy (CIN)

    International Nuclear Information System (INIS)

    Kuwatsuru, Ryohei

    2011-01-01

    Despite advances in imaging diagnosis, contrast media still play an important role in diagnosing the existence of the disease, demonstrating the extent of disease, and determining the perfusion of the disease, which is important to make a differential diagnosis. However, the administration of contrast media may cause contrast-induced nephropathy (CIN), especially in patients with renal impairment. It is estimated that 20-30% of patients with renal impairment who received contrast media develop CIN. Though the precise cause of CIN currently remains unknown, almost all injected contrast media are excreted through the kidney and the effects of contrast media on the kidney are easily understood. As CIN is the most common cause of death due to complications after receiving contrast media, prevention of CIN is important. There are several known risk factors for CIN. Patients with renal impairment, diabetes mellitus, and dehydration are at high risk for CIN. Furthermore, a high osmolar contrast media, excessive amount of contrast media, and ionic contrast media are also risk factors for CIN. CIN can be prevented in several ways. Certain drugs seem to be useful to prevent CIN, while others are harmful. Hydration is useful to prevent CIN, although there is no widely acceptable hydration method to prevent CIN. Both sodium bicarbonate and N-acetylcysteine are promising candidates for prevention of CIN. There are few reports to study CIN after intravenous administration, although reports of CIN after percutaneous cardiac intervention (PCI) and angiography are well recognized. In clinical situations, intravenous administration of contrast media is common. Therefore, a study of CIN after intravenous administration of contrast media should be performed. (author)

  11. A prospective study on the risk of contrast induced nephropathy in the patients who underwent contrast-enhanced CT examination

    International Nuclear Information System (INIS)

    Zhang Baocui; Zhang Yudong; Zhao Kai; Wang Xiaoying; Jiang Xuexiang

    2013-01-01

    Objective: To investigate the incidence of contrast induced nephropathy (CIN) among different patient groups after contrast agent injection. Methods: A total of 1243 patients were included in this study (male = 694, female = 549). The SCr level one week before and 72 hours after the CT examination and the incidence of CIN were recorded and comparison was made among groups according to sex, age, body mass index (BMI), the history of high blood pressure (HBP), diabetes mellitus (DM), chronic kidney disease (CKD), chronic heart failure (CHF), tumor, nephrotoxicity drug (NTD) usage. The frequency, type, dose and injection velocity of the contrast media (CM) were also recorded. Multivariate predictors of CIN were identified by Logistic regression using step-wise selection with entry and exit criteria of P 1). Conclusion: Women, age ≥ 75 years, LOCM, NTD, tumor, and the frequency of using CM more than once per month were more likely to develop CIN. (authors)

  12. Highly stable silica-coated manganese ferrite nanoparticles as high-efficacy T2 contrast agents for magnetic resonance imaging

    Science.gov (United States)

    Ahmad, Ashfaq; Bae, Hongsub; Rhee, Ilsu

    2018-05-01

    Highly stable silica-coated manganese ferrite nanoparticles were fabricated for application as magnetic resonance imagining (MRI) contrast agents. The manganese ferrite nanoparticles were synthesized using a hydrothermal technique and coated with silica. The particle size was investigated using transmission electron microscopy and was found to be 40-60 nm. The presence of the silica coating on the particle surface was confirmed by Fourier transform infrared spectroscopy. The crystalline structure was investigated by X-ray diffraction, and the particles were revealed to have an inverse spinel structure. Superparamagnetism was confirmed by the magnetic hysteresis curves obtained using a vibrating sample magnetometer. The efficiency of the MRI contrast agents was investigated by using aqueous solutions of the particles in a 4.7 T MRI scanner. The T1 and T2 relaxivities of the particles were 1.42 and 60.65 s-1 mM-1, respectively, in water. The ratio r2/r1 was 48.91, confirming that the silica-coated manganese ferrite nanoparticles were suitable high-efficacy T2 contrast agents.

  13. DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-contrast Astronomy

    Science.gov (United States)

    Meeker, Seth R.; Mazin, Benjamin A.; Walter, Alex B.; Strader, Paschal; Fruitwala, Neelay; Bockstiegel, Clint; Szypryt, Paul; Ulbricht, Gerhard; Coiffard, Grégoire; Bumble, Bruce; Cancelo, Gustavo; Zmuda, Ted; Treptow, Ken; Wilcer, Neal; Collura, Giulia; Dodkins, Rupert; Lipartito, Isabel; Zobrist, Nicholas; Bottom, Michael; Shelton, J. Chris; Mawet, Dimitri; van Eyken, Julian C.; Vasisht, Gautam; Serabyn, Eugene

    2018-06-01

    We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at frame rates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. Here, we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.

  14. Renal clearance of an ionic high-osmolar and a nonionic low-osmolar contrast medium

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Vestergaard, A.; Nielsen, S.L.; Fogh-Andersen, N.; Golman, K.; Dorph, S.

    1991-01-01

    One hundred patients with normal serum creatinine concentration underwent intravenous urography with either an ionic high-osmolar (diatrizoate) or a nonionic low-osmolar (iopamidol) contrast medium after randomization. Before injection of the contrast medium, a blood sample was drawn for determinating serum creatinine concentration, and a urine sample for measurement of urine osmolality. Using x-ray fluorescence, the plasma concentration of iodine (contrast medium) was determined on blood samples drawn approximately 3 and 4 hours after injection of the contrast medium. The glomerular filtration rate was calculated by two different formulas: one requiring only a single sample and one requiring at least two samples (standard). There were poor correlations between the standard contrast medium clearance and the serum creatinine concentration, the estimated creatinine clearance (calculated from a nomogram), as well as the urine osmolality. The 3-hour and the 4-hour single-sample values correlated well with the two-sample values for both contrast media. In patients with normal serum creatinine, the glomerular filtration rate determined by measuring the contrast medium concentration in a single plasma sample obtained at 3 hours, is almost identical to the value determined from two samples. Consequently, two samples are unnecessary

  15. Bounds and Estimates for Transport Coefficients of Random and Porous Media with High Contrasts

    International Nuclear Information System (INIS)

    Berryman, J G

    2004-01-01

    Bounds on transport coefficients of random polycrystals of laminates are presented, including the well-known Hashin-Shtrikman bounds and some newly formulated bounds involving two formation factors for a two-component porous medium. Some new types of self-consistent estimates are then formulated based on the observed analytical structure both of these bounds and also of earlier self-consistent estimates (of the CPA or coherent potential approximation type). A numerical study is made, assuming first that the internal structure (i.e., the laminated grain structure) is not known, and then that it is known. The purpose of this aspect of the study is to attempt to quantify the differences in the predictions of properties of a system being modeled when such organized internal structure is present in the medium but detailed spatial correlation information may or (more commonly) may not be available. Some methods of estimating formation factors from data are also presented and then applied to a high-contrast fluid-permeability data set. Hashin-Shtrikman bounds are found to be very accurate estimates for low contrast heterogeneous media. But formation factor lower bounds are superior estimates for high contrast situations. The new self-consistent estimators also tend to agree better with data than either the bounds or the CPA estimates, which themselves tend to overestimate values for high contrast conducting composites

  16. Geometric variations in high index-contrast waveguides, coupled mode theory in curvilinear coordinates.

    Science.gov (United States)

    Skorobogatiy, Maksim; Jacobs, Steven; Johnson, Steven; Fink, Yoel

    2002-10-21

    Perturbation theory formulation of Maxwell's equations gives a theoretically elegant and computationally efficient way of describing small imperfections and weak interactions in electro-magnetic systems. It is generally appreciated that due to the discontinuous field boundary conditions in the systems employing high dielectric contrast profiles standard perturbation formulations fail when applied to the problem of shifted material boundaries. In this paper we developed a novel coupled mode and perturbation theory formulations for treating generic non-uniform (varying along the direction of propagation) perturbations of a waveguide cross-section based on Hamiltonian formulation of Maxwell equations in curvilinear coordinates. We show that our formulation is accurate and rapidly converges to an exact result when used in a coupled mode theory framework even for the high index-contrast discontinuous dielectric profiles. Among others, our formulation allows for an efficient numerical evaluation of induced PMD due to a generic distortion of a waveguide profile, analysis of mode filters, mode converters and other optical elements such as strong Bragg gratings, tapers, bends etc., and arbitrary combinations of thereof. To our knowledge, this is the first time perturbation and coupled mode theories are developed to deal with arbitrary non-uniform profile variations in high index-contrast waveguides.

  17. High-contrast controllable switching based on polystyrene nonlinear cavities in 2D hole-type photonic crystals

    Science.gov (United States)

    Paghousi, Roohollah; Fasihi, Kiazand

    2018-05-01

    We present a new high-contrast controllable switch, which is based on a polystyrene nonlinear cavity, and is implemented in a two dimensional (2D) hole-type photonic crystal (PC). We show that by applying a control signal, the input power can be transmitted to the output waveguide with a high contrast ratio. The operation of the proposed device is investigated through the use of coupled-mode theory (CMT) and finite-difference time-domain (FDTD) method. The contrast ratio of the proposed device varies between 18 and 23, which is higher than the corresponding value in the previous investigations. Based on the simulation results, with increasing the control power the range of operating power will be increased, while the contrast ratio will be decreased. It has been shown that in a modified structure, at the expense of the range of operating power and the contrast ratio, the control power can be decreased, considerably.

  18. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  19. High Contrast Imaging of Exoplanets and Exoplanetary Systems with JWST

    Science.gov (United States)

    Hinkley, Sasha; Skemer, Andrew; Biller, Beth; Baraffe, I.; Bonnefoy, M.; Bowler, B.; Carter, A.; Chen, C.; Choquet, E.; Currie, T.; Danielski, C.; Fortney, J.; Grady, C.; Greenbaum, A.; Hines, D.; Janson, M.; Kalas, P.; Kennedy, G.; Kraus, A.; Lagrange, A.; Liu, M.; Marley, M.; Marois, C.; Matthews, B.; Mawet, D.; Metchev, S.; Meyer, M.; Millar-Blanchaer, M.; Perrin, M.; Pueyo, L.; Quanz, S.; Rameau, J.; Rodigas, T.; Sallum, S.; Sargent, B.; Schlieder, J.; Schneider, G.; Stapelfeldt, K.; Tremblin, P.; Vigan, A.; Ygouf, M.

    2017-11-01

    JWST will transform our ability to characterize directly imaged planets and circumstellar debris disks, including the first spectroscopic characterization of directly imaged exoplanets at wavelengths beyond 5 microns, providing a powerful diagnostic of cloud particle properties, atmospheric structure, and composition. To lay the groundwork for these science goals, we propose a 39-hour ERS program to rapidly establish optimal strategies for JWST high contrast imaging. We will acquire: a) coronagraphic imaging of a newly discovered exoplanet companion, and a well-studied circumstellar debris disk with NIRCam & MIRI; b) spectroscopy of a wide separation planetary mass companion with NIRSPEC & MIRI; and c) deep aperture masking interferometry with NIRISS. Our primary goals are to: 1) generate representative datasets in modes to be commonly used by the exoplanet and disk imaging communities; 2) deliver science enabling products to empower a broad user base to develop successful future investigations; and 3) carry out breakthrough science by characterizing exoplanets for the first time over their full spectral range from 2-28 microns, and debris disk spectrophotometry out to 15 microns sampling the 3 micron water ice feature. Our team represents the majority of the community dedicated to exoplanet and disk imaging and has decades of experience with high contrast imaging algorithms and pipelines. We have developed a collaboration management plan and several organized working groups to ensure we can rapidly and effectively deliver high quality Science Enabling Products to the community.

  20. Teachable, high-content analytics for live-cell, phase contrast movies.

    Science.gov (United States)

    Alworth, Samuel V; Watanabe, Hirotada; Lee, James S J

    2010-09-01

    CL-Quant is a new solution platform for broad, high-content, live-cell image analysis. Powered by novel machine learning technologies and teach-by-example interfaces, CL-Quant provides a platform for the rapid development and application of scalable, high-performance, and fully automated analytics for a broad range of live-cell microscopy imaging applications, including label-free phase contrast imaging. The authors used CL-Quant to teach off-the-shelf universal analytics, called standard recipes, for cell proliferation, wound healing, cell counting, and cell motility assays using phase contrast movies collected on the BioStation CT and BioStation IM platforms. Similar to application modules, standard recipes are intended to work robustly across a wide range of imaging conditions without requiring customization by the end user. The authors validated the performance of the standard recipes by comparing their performance with truth created manually, or by custom analytics optimized for each individual movie (and therefore yielding the best possible result for the image), and validated by independent review. The validation data show that the standard recipes' performance is comparable with the validated truth with low variation. The data validate that the CL-Quant standard recipes can provide robust results without customization for live-cell assays in broad cell types and laboratory settings.

  1. High-contrast 3D image acquisition using HiLo microscopy with an electrically tunable lens

    Science.gov (United States)

    Philipp, Katrin; Smolarski, André; Fischer, Andreas; Koukourakis, Nektarios; Stürmer, Moritz; Wallrabe, Ulricke; Czarske, Jürgen

    2016-04-01

    We present a HiLo microscope with an electrically tunable lens for high-contrast three-dimensional image acquisition. HiLo microscopy combines wide field and speckled illumination images to create optically sectioned images. Additionally, the depth-of-field is not fixed, but can be adjusted between wide field and confocal-like axial resolution. We incorporate an electrically tunable lens in the HiLo microscope for axial scanning, to obtain three-dimensional data without the need of moving neither the sample nor the objective. The used adaptive lens consists of a transparent polydimethylsiloxane (PDMS) membrane into which an annular piezo bending actuator is embedded. A transparent fluid is filled between the membrane and the glass substrate. When actuated, the piezo generates a pressure in the lens which deflects the membrane and thus changes the refractive power. This technique enables a large tuning range of the refractive power between 1/f = (-24 . . . 25) 1/m. As the NA of the adaptive lens is only about 0.05, a fixed high-NA lens is included in the setup to provide high resolution. In this contribution, the scan properties and capabilities of the tunable lens in the HiLo microscope are analyzed. Eventually, exemplary measurements are presented and discussed.

  2. High-contrast gratings for long-wavelength laser integration on silicon

    Science.gov (United States)

    Sciancalepore, Corrado; Descos, Antoine; Bordel, Damien; Duprez, Hélène; Letartre, Xavier; Menezo, Sylvie; Ben Bakir, Badhise

    2014-02-01

    Silicon photonics is increasingly considered as the most promising way-out to the relentless growth of data traffic in today's telecommunications infrastructures, driving an increase in transmission rates and computing capabilities. This is in fact challenging the intrinsic limit of copper-based, short-reach interconnects and microelectronic circuits in data centers and server architectures to offer enough modulation bandwidth at reasonable power dissipation. In the context of the heterogeneous integration of III-V direct-bandgap materials on silicon, optics with high-contrast metastructures enables the efficient implementation of optical functions such as laser feedback, input/output (I/O) to active/passive components, and optical filtering, while heterogeneous integration of III-V layers provides sufficient optical gain, resulting in silicon-integrated laser sources. The latest ensure reduced packaging costs and reduced footprint for the optical transceivers, a key point for the short reach communications. The invited talk will introduce the audience to the latest breakthroughs concerning the use of high-contrast gratings (HCGs) for the integration of III-V-on-Si verticalcavity surface-emitting lasers (VCSELs) as well as Fabry-Perot edge-emitters (EELs) in the main telecom band around 1.55 μm. The strong near-field mode overlap within HCG mirrors can be exploited to implement unique optical functions such as dense wavelength division multiplexing (DWDM): a 16-λ100-GHz-spaced channels VCSEL array is demonstrated. On the other hand, high fabrication yields obtained via molecular wafer bonding of III-V alloys on silicon-on-insulator (SOI) conjugate excellent device performances with cost-effective high-throughput production, supporting industrial needs for a rapid research-to-market transfer.

  3. High Performance Object-Oriented Scientific Programming in Fortran 90

    Science.gov (United States)

    Norton, Charles D.; Decyk, Viktor K.; Szymanski, Boleslaw K.

    1997-01-01

    We illustrate how Fortran 90 supports object-oriented concepts by example of plasma particle computations on the IBM SP. Our experience shows that Fortran 90 and object-oriented methodology give high performance while providing a bridge from Fortran 77 legacy codes to modern programming principles. All of our object-oriented Fortran 90 codes execute more quickly thatn the equeivalent C++ versions, yet the abstraction modelling capabilities used for scentific programming are comparably powereful.

  4. Mode decomposition methods for flows in high-contrast porous media. A global approach

    KAUST Repository

    Ghommem, Mehdi; Calo, Victor M.; Efendiev, Yalchin R.

    2014-01-01

    We apply dynamic mode decomposition (DMD) and proper orthogonal decomposition (POD) methods to flows in highly-heterogeneous porous media to extract the dominant coherent structures and derive reduced-order models via Galerkin projection. Permeability fields with high contrast are considered to investigate the capability of these techniques to capture the main flow features and forecast the flow evolution within a certain accuracy. A DMD-based approach shows a better predictive capability due to its ability to accurately extract the information relevant to long-time dynamics, in particular, the slowly-decaying eigenmodes corresponding to largest eigenvalues. Our study enables a better understanding of the strengths and weaknesses of the applicability of these techniques for flows in high-contrast porous media. Furthermore, we discuss the robustness of DMD- and POD-based reduced-order models with respect to variations in initial conditions, permeability fields, and forcing terms. © 2013 Elsevier Inc.

  5. The forgotten organ: Contrast enhanced sonography of the spleen

    International Nuclear Information System (INIS)

    Goerg, Christian

    2007-01-01

    Objective: Ultrasound contrast agents in conjunction with contrast specific imaging techniques, are increasingly accepted in clinical use for diagnostic imaging in several organs. Contrast enhanced sonography (CES) of second-generation contrast media have shown a spleen-specific uptake of the microbubble contrast agent. The aim of this review is to illustrate indications for the use of CES in patients with suspected (peri-)splenic pathology. Methods: This review based on the experience of transcutaneous CES in 200 patients with (peri-)splenic pathology diagnosed by B-mode sonography at an internal medicine center. CES studies were performed with a contrast-devoted unit (Acuson, Sequoia, Siemens medical solution) that had contrast-specific, continuous-mode software. A low mechanical index was used. A sulfur hexafluoride-based microbubble contrast medium (Sonovue, Bracco SpA, Milan, Italy) was injected. Results: On our experience, there are several clinical conditions which may show an diagnostic advantage of CES in comparison to B-mode US. CES should be performed to investigate: (1) the perisplenic tumor to diagnose or exclude accessory spleen, (2) the small-sized spleen to diagnose functional asplenia/hyposplenia, (3) the inhomogenous spleen of unknown cause to diagnose focal lesions within the spleen, (4) the incidentally found hypoechoic splenic tumor to diagnose high vascular splenic hemangioma, (5) focal lesions suspect for splenic abscess, hematoma, infarction to confirme diagnosis, and (6) patients with abdominal trauma to diagnose or exclude splenic injuriy. Conclusion: CES is of diagnostic value in several clinical circumstances to diagnose accessory spleen, functional asplenia, small-sized splenic involvement, high vascular splenic hemangioma, and vascular splenic pathology like splenic infarction, splenic abscess, and splenic laceration

  6. The forgotten organ: Contrast enhanced sonography of the spleen

    Energy Technology Data Exchange (ETDEWEB)

    Goerg, Christian [Medizinische Universitaetsklinik, Baldingerstrasse, 35043 Marburg/Lahn (Germany)], E-mail: goergc@med.uni-marburg.de

    2007-11-15

    Objective: Ultrasound contrast agents in conjunction with contrast specific imaging techniques, are increasingly accepted in clinical use for diagnostic imaging in several organs. Contrast enhanced sonography (CES) of second-generation contrast media have shown a spleen-specific uptake of the microbubble contrast agent. The aim of this review is to illustrate indications for the use of CES in patients with suspected (peri-)splenic pathology. Methods: This review based on the experience of transcutaneous CES in 200 patients with (peri-)splenic pathology diagnosed by B-mode sonography at an internal medicine center. CES studies were performed with a contrast-devoted unit (Acuson, Sequoia, Siemens medical solution) that had contrast-specific, continuous-mode software. A low mechanical index was used. A sulfur hexafluoride-based microbubble contrast medium (Sonovue, Bracco SpA, Milan, Italy) was injected. Results: On our experience, there are several clinical conditions which may show an diagnostic advantage of CES in comparison to B-mode US. CES should be performed to investigate: (1) the perisplenic tumor to diagnose or exclude accessory spleen, (2) the small-sized spleen to diagnose functional asplenia/hyposplenia, (3) the inhomogenous spleen of unknown cause to diagnose focal lesions within the spleen, (4) the incidentally found hypoechoic splenic tumor to diagnose high vascular splenic hemangioma, (5) focal lesions suspect for splenic abscess, hematoma, infarction to confirme diagnosis, and (6) patients with abdominal trauma to diagnose or exclude splenic injuriy. Conclusion: CES is of diagnostic value in several clinical circumstances to diagnose accessory spleen, functional asplenia, small-sized splenic involvement, high vascular splenic hemangioma, and vascular splenic pathology like splenic infarction, splenic abscess, and splenic laceration.

  7. High spatial resolution magnetic resonance imaging of experimental cerebral venous thrombosis with a blood pool contrast agent

    International Nuclear Information System (INIS)

    Spuentrup, E.; Wiethoff, A.J.; Parsons, E.C.; Spangenberg, P.; Stracke, C.P.

    2010-01-01

    Purpose: The purpose of this study was to investigate the feasibility of clot visualization in small sinus and cortical veins with contrast enhanced MRA in a cerebral venous thrombosis animal model using a blood pool contrast agent, Gadofosveset, and high spatial resolution imaging. Material and methods: For induction of cerebral venous thrombosis a recently developed combined interventional and microsurgical model was used. Cerebral sinus and cortical vein thrombosis was induced in six pigs. Two further pigs died during the procedure. Standard structural, time-of-flight- and phase contrast-angiograms were followed by fast time resolved high resolution 3D MRA (4D MRA) and subsequent high spatial resolution 3D MRA in the equilibrium phase with and without addition of parallel imaging. Visualization of the clots using the different sequences was subjectively compared and contrast-to-noise ratio (CNR) was assessed. Results: In the remaining six animals the procedure and MR-imaging protocol including administration of Gadofosveset was successfully completed. The 3D high resolution MRA in the equilibrium phase without the addition of parallel imaging was superior to all the other applied MR measurement techniques in terms of visualization of the clots. Only applying this sequence bridging vein thromboses were also seen as a small filling defect with a high CNR of >18. Conclusion: Only the non-accelerated high spatial resolution 3D MRA in the equilibrium in conjunction with the blood pool agent Gadofosveset allows for high-contrast visualization of very small clots in the cerebral sinus and cortical veins. Statement clinical impact: Detection of cortical vein thrombosis is of high clinical impact. Conventional MRI sequences often fail to visualize the clot. We could demonstrate that, in contrast to conventional sequences, with high spatial resolution 3D MRA in the equilibrium in conjunction with the blood pool agent Gadofosveset very small clots in the cerebral sinus and

  8. Dual focal-spot imaging for phase extraction in phase-contrast radiography

    International Nuclear Information System (INIS)

    Donnelly, Edwin F.; Price, Ronald R.; Pickens, David R.

    2003-01-01

    The purpose of this study was to evaluate dual focal spot imaging as a method for extracting the phase component from a phase-contrast radiography image. All measurements were performed using a microfocus tungsten-target x-ray tube with an adjustable focal-spot size (0.01 mm to 0.045 mm). For each object, high-resolution digital radiographs were obtained with two different focal spot sizes to produce matched image pairs in which all other geometric variables as well as total exposure and tube kVp were held constant. For each image pair, a phase extraction was performed using pixel-wise division. The phase-extracted image resulted in an image similar to the standard image processing tool commonly referred to as 'unsharp masking' but with the additional edge-enhancement produced by phase-contrast effects. The phase-extracted image illustrates the differences between the two images whose imaging parameters differ only in focal spot size. The resulting image shows effects from both phase contrast as well as geometric unsharpness. In weakly attenuating materials the phase-contrast effect predominates, while in strongly attenuating materials the phase effects are so small that they are not detectable. The phase-extracted image in the strongly attenuating object reflects differences in geometric unsharpness. The degree of phase extraction depends strongly on the size of the smallest focal spot used. This technique of dual-focal spot phase-contrast radiography provides a simple technique for phase-component (edge) extraction in phase-contrast radiography. In strongly attenuating materials the phase-component is overwhelmed by differences in geometric unsharpness. In these cases the technique provides a form of unsharp masking which also accentuates the edges. Thus, the two effects are complimentary and may be useful in the detection of small objects

  9. High-Contrast 3.8 Micron Imaging of the Brown Dwarf/Planet-Mass Companion to GJ 758

    Science.gov (United States)

    Currie, Thayne M.; Bailey, Vanessa; Fabrycky, Daniel; Murray-Clay, Ruth; Rodigas, Timothy; Hinz, Phil

    2011-01-01

    We present L' band (3.8 Micron) MMT/Clio high-contrast imaging data for the nearby star GJ 758, which was recently reported by Thalmann et al. (2009) to have one - possibly two - faint comoving companions (GJ 7588 and "C", respectively). GJ 758B is detected in two distinct datasets. Additionally, we report a \\textit{possible} detection of the object identified by Thalmann et al as "GJ 758C" in our more sensitive dataset, though it is likely a residual speckle. However, if it is the same object as that reported by Thalmann et al. it cannot be a companion in a bound orbit. GJ 7588 has a H-L' color redder than nearly all known L-T8 dwarfs. 8ased on comparisons with the COND evolutionary models, GJ 7588 has Te approx. 560 K (+150 K, -90 K) and a mass ranging from approx.10-20 Mj if it is approx.1 Gyr old to approx. 25-40 Mj if it is 8.7 Gyr old. GJ 7588 is likely in a highly eccentric orbit, e approx. 0.73 (+0.12,-0.21), with a semimajor axis of approx. 44 AU (+32 AU, -14 AU). Though GJ 7588 is sometimes discussed within the context of exoplanet direct imaging, its mass is likely greater than the deuterium-burning limit and its formation may resemble that of binary stars rather than that of jovian-mass planets.

  10. Balkanizing the primate orbitofrontal cortex: distinct subregions for comparing and contrasting values.

    Science.gov (United States)

    Rudebeck, Peter H; Murray, Elisabeth A

    2011-12-01

    The primate orbitofrontal cortex (OFC) is often treated as a single entity, but architectonic and connectional neuroanatomy indicate that it has distinguishable parts. Nevertheless, few studies have attempted to dissociate the functions of its subregions. Here we review findings from recent neuropsychological and neurophysiological studies that do so. The lateral OFC seems to be important for learning, representing, and updating specific object-reward associations. The medial OFC seems to be important for value comparisons and choosing among objects on that basis. Rather than viewing this dissociation of function in terms of learning versus choosing, however, we suggest that it reflects the distinction between contrasts and comparisons: differences versus similarities. Making use of high-dimensional representations that arise from the convergence of several sensory modalities, the lateral OFC encodes contrasts among outcomes. The medial OFC reduces these contrasting representations of value to a single dimension, a common currency, in order to compare alternative choices. © 2011 New York Academy of Sciences.

  11. CT Image Contrast of High-Z Elements: Phantom Imaging Studies and Clinical Implications.

    Science.gov (United States)

    FitzGerald, Paul F; Colborn, Robert E; Edic, Peter M; Lambert, Jack W; Torres, Andrew S; Bonitatibus, Peter J; Yeh, Benjamin M

    2016-03-01

    To quantify the computed tomographic (CT) image contrast produced by potentially useful contrast material elements in clinically relevant imaging conditions. Equal mass concentrations (grams of active element per milliliter of solution) of seven radiodense elements, including iodine, barium, gadolinium, tantalum, ytterbium, gold, and bismuth, were formulated as compounds in aqueous solutions. The compounds were chosen such that the active element dominated the x-ray attenuation of the solution. The solutions were imaged within a modified 32-cm CT dose index phantom at 80, 100, 120, and 140 kVp at CT. To simulate larger body sizes, 0.2-, 0.5-, and 1.0-mm-thick copper filters were applied. CT image contrast was measured and corrected for measured concentrations and presence of chlorine in some compounds. Each element tested provided higher image contrast than iodine at some tube potential levels. Over the range of tube potentials that are clinically practical for average-sized and larger adults-that is, 100 kVp and higher-barium, gadolinium, ytterbium, and tantalum provided consistently increased image contrast compared with iodine, respectively demonstrating 39%, 56%, 34%, and 24% increases at 100 kVp; 39%, 66%, 53%, and 46% increases at 120 kVp; and 40%, 72%, 65%, and 60% increases at 140 kVp, with no added x-ray filter. The consistently high image contrast produced with 100-140 kVp by tantalum compared with bismuth and iodine at equal mass concentration suggests that tantalum could potentially be favorable for use as a clinical CT contrast agent.

  12. Analyser-based phase contrast image reconstruction using geometrical optics

    International Nuclear Information System (INIS)

    Kitchen, M J; Pavlov, K M; Siu, K K W; Menk, R H; Tromba, G; Lewis, R A

    2007-01-01

    Analyser-based phase contrast imaging can provide radiographs of exceptional contrast at high resolution (<100 μm), whilst quantitative phase and attenuation information can be extracted using just two images when the approximations of geometrical optics are satisfied. Analytical phase retrieval can be performed by fitting the analyser rocking curve with a symmetric Pearson type VII function. The Pearson VII function provided at least a 10% better fit to experimentally measured rocking curves than linear or Gaussian functions. A test phantom, a hollow nylon cylinder, was imaged at 20 keV using a Si(1 1 1) analyser at the ELETTRA synchrotron radiation facility. Our phase retrieval method yielded a more accurate object reconstruction than methods based on a linear fit to the rocking curve. Where reconstructions failed to map expected values, calculations of the Takagi number permitted distinction between the violation of the geometrical optics conditions and the failure of curve fitting procedures. The need for synchronized object/detector translation stages was removed by using a large, divergent beam and imaging the object in segments. Our image acquisition and reconstruction procedure enables quantitative phase retrieval for systems with a divergent source and accounts for imperfections in the analyser

  13. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    Science.gov (United States)

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  14. Iodine-based contrast media, multiple myeloma and monoclonal gammopathies

    DEFF Research Database (Denmark)

    Stacul, Fulvio; Bertolotto, Michele; Thomsen, Henrik S

    2018-01-01

    OBJECTIVES: Many radiologists and clinicians still consider multiple myeloma (MM) and monoclonal gammopathies (MG) a contraindication for using iodine-based contrast media. The ESUR Contrast Media Safety Committee performed a systematic review of the incidence of post-contrast acute kidney injury...

  15. High-contrast laser acceleration of relativistic electrons in solid cone-wire targets

    Energy Technology Data Exchange (ETDEWEB)

    Higginson, D. P. [Univ. of California-San Diego, La Jolla, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Link, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sawada, H. [Univ. of California-San Diego, La Jolla, CA (United States); Wilks, S. C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chawla, S. R. [Univ. of California-San Diego, La Jolla, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chen, C. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jarrott, L. C. [Univ. of California-San Diego, La Jolla, CA (United States); Flippo, K. A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McLean, H. S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Patel, P. K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Perez, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Beg, F. N. [Univ. of California-San Diego, La Jolla, CA (United States); Bartal, T. [Univ. of California-San Diego, La Jolla, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wei, M. S. [General Atomics, San Diego, CA (United States)

    2015-12-31

    Optimization of electron coupling into small solid angles is of extreme importance to applications, such as Fast Ignition, that require maximum electron energy deposition within a small volume. To optimize this coupling, we use the ultra-high-contrast Trident laser, which remains below intensity of 1011 W/cm2 until < 0.1 ns before the main pulse, while still attaining high-energy, 75 J, and peak intensity of 5 x 1019 W/cm2. Using a cone-wire target, we find that the coupling into the 40 μm diameter wire is increased by a factor of 2.7x over the low-contrast Titan laser at similar peak intensity. Full-scale simulations are used to model the laser interaction and quantitatively reproduce the experimental results. These show that increase in coupling is due to both a closer interaction, as well as the reduction of laser filamentation and self-focusing.

  16. Comparison of low contrast detectability of computed tomography and screen/film mammography systems

    International Nuclear Information System (INIS)

    Noriah Jamal; Kwan Hoong Ng; McLean, D.

    2006-01-01

    The objective of this study was to compare low contrast detectability of computed radiography (CR) and screen/film (SF) mammography systems. The Nijimegen contrast detail test object (CDMAM type 3.4) was imaged at 28 kV, in automatic exposure control mode separately. Six medical imaging physicists read each CDMAM phantom image. Contrast detail curves were plotted to compare low contrast detectability of CR (soft copy and hard copy) and SF mammography systems. Effect of varying exposure parameters, namely kV, object position inside the breast phantom, and entrance surface exposure (ESE) on the contrast detail curve were also investigated using soft copy CR. The significant of the difference of contrast between CR and SF, and for each exposure parameter was tested using non-parametric Kruskal-Wallis test. We found that the low contrast detectability of CR (soft copy and hard copy) system is not significantly different to that of SF system (p>0.05, Kruskal-Wallis test). For CR soft copy, no significant relationship (p>0.05, Kruskal-Wallis test) was seen for variation of kV, object position inside the breast phantom and ESE. This indicates that CR is comparable with SF for useful detection and visualization of low contrast objects such as small low contrast areas corresponding to breast pathology

  17. Multiscale modeling of high contrast brinkman equations with applications to deformable porous media

    KAUST Repository

    Brown, Donald

    2013-06-18

    Simulating porous media flows has a wide range of applications. Often, these applications involve many scales and multi-physical processes. A useful tool in the analysis of such problems in that of homogenization as an averaged description is derived circumventing the need for complicated simulation of the fine scale features. In this work, we recall recent developments of homogenization techniques in the application of flows in deformable porous media. In addition, homogenization of media with high-contrast. In particular, we recall the main ideas of the homogenization of slowly varying Stokes flow and summarize the results of [4]. We also present the ideas for extending these techniques to high-contrast deformable media [3]. These ideas are connected by the modeling of multiscale fluid-structure interaction problems. © 2013 American Society of Civil Engineers.

  18. On the influence of the electron dose rate on the HRTEM image contrast

    Energy Technology Data Exchange (ETDEWEB)

    Barthel, Juri, E-mail: ju.barthel@fz-juelich.de [RWTH Aachen University, Ahornstraße 55, 52074 Aachen (Germany); Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Lentzen, Markus; Thust, Andreas [Peter Grünberg Institute, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany)

    2017-05-15

    We investigate a possible dependence between the applied electron dose-rate and the magnitude of the resulting image contrast in HRTEM of inorganic crystalline objects. The present study is focussed on the question whether electron irradiation can induce excessively strong atom vibrations or displacements, which in turn could significantly reduce the resulting image contrast. For this purpose, high-resolution images of MgO, Ge, and Au samples were acquired with varying dose rates using a C{sub S}-corrected FEI Titan 80–300 microscope operated at 300 kV accelerating voltage. This investigation shows that the magnitude of the signal contrast is independent from the dose rates occurring in conventional HRTEM experiments and that excessively strong vibrations or displacements of bulk atoms are not induced by the applied electron irradiation. - Highlights: • No dependence between electron dose rate and HRTEM image contrast is found. • This finding is in full accordance with established solid-state physics theory. • Object-related causes for the previous Stobbs-factor phenomenon are ruled out.

  19. A robust object-based shadow detection method for cloud-free high resolution satellite images over urban areas and water bodies

    Science.gov (United States)

    Tatar, Nurollah; Saadatseresht, Mohammad; Arefi, Hossein; Hadavand, Ahmad

    2018-06-01

    Unwanted contrast in high resolution satellite images such as shadow areas directly affects the result of further processing in urban remote sensing images. Detecting and finding the precise position of shadows is critical in different remote sensing processing chains such as change detection, image classification and digital elevation model generation from stereo images. The spectral similarity between shadow areas, water bodies, and some dark asphalt roads makes the development of robust shadow detection algorithms challenging. In addition, most of the existing methods work on pixel-level and neglect the contextual information contained in neighboring pixels. In this paper, a new object-based shadow detection framework is introduced. In the proposed method a pixel-level shadow mask is built by extending established thresholding methods with a new C4 index which enables to solve the ambiguity of shadow and water bodies. Then the pixel-based results are further processed in an object-based majority analysis to detect the final shadow objects. Four different high resolution satellite images are used to validate this new approach. The result shows the superiority of the proposed method over some state-of-the-art shadow detection method with an average of 96% in F-measure.

  20. Image fusion in x-ray differential phase-contrast imaging

    Science.gov (United States)

    Haas, W.; Polyanskaya, M.; Bayer, F.; Gödel, K.; Hofmann, H.; Rieger, J.; Ritter, A.; Weber, T.; Wucherer, L.; Durst, J.; Michel, T.; Anton, G.; Hornegger, J.

    2012-02-01

    Phase-contrast imaging is a novel modality in the field of medical X-ray imaging. The pioneer method is the grating-based interferometry which has no special requirements to the X-ray source and object size. Furthermore, it provides three different types of information of an investigated object simultaneously - absorption, differential phase-contrast and dark-field images. Differential phase-contrast and dark-field images represent a completely new information which has not yet been investigated and studied in context of medical imaging. In order to introduce phase-contrast imaging as a new modality into medical environment the resulting information about the object has to be correctly interpreted. The three output images reflect different properties of the same object the main challenge is to combine and visualize these data in such a way that it diminish the information explosion and reduce the complexity of its interpretation. This paper presents an intuitive image fusion approach which allows to operate with grating-based phase-contrast images. It combines information of the three different images and provides a single image. The approach is implemented in a fusion framework which is aimed to support physicians in study and analysis. The framework provides the user with an intuitive graphical user interface allowing to control the fusion process. The example given in this work shows the functionality of the proposed method and the great potential of phase-contrast imaging in medical practice.

  1. Quantitative evaluation of contrast agent uptake in standard fat-suppressed dynamic contrast-enhanced MRI examinations of the breast.

    Science.gov (United States)

    Kousi, Evanthia; Smith, Joely; Ledger, Araminta E; Scurr, Erica; Allen, Steven; Wilson, Robin M; O'Flynn, Elizabeth; Pope, Romney J E; Leach, Martin O; Schmidt, Maria A

    2018-01-01

    To propose a method to quantify T 1 and contrast agent uptake in breast dynamic contrast-enhanced (DCE) examinations undertaken with standard clinical fat-suppressed MRI sequences and to demonstrate the proposed approach by comparing the enhancement characteristics of lobular and ductal carcinomas. A standard fat-suppressed DCE of the breast was performed at 1.5 T (Siemens Aera), followed by the acquisition of a proton density (PD)-weighted sequence, also fat suppressed. Both sequences were characterized with test objects (T 1 ranging from 30 ms to 2,400 ms) and calibration curves were obtained to enable T 1 calculation. The reproducibility and accuracy of the calibration curves were also investigated. Healthy volunteers and patients were scanned with Ethics Committee approval. The effect of B 0 field inhomogeneity was assessed in test objects and healthy volunteers. The T 1 of breast tumors was calculated at different time points (pre-, peak-, and post-contrast agent administration) for 20 patients, pre-treatment (10 lobular and 10 ductal carcinomas) and the two cancer types were compared (Wilcoxon rank-sum test). The calibration curves proved to be highly reproducible (coefficient of variation under 10%). T 1 measurements were affected by B 0 field inhomogeneity, but frequency shifts below 50 Hz introduced only 3% change to fat-suppressed T 1 measurements of breast parenchyma in volunteers. The values of T 1 measured pre-, peak-, and post-contrast agent administration demonstrated that the dynamic range of the DCE sequence was correct, that is, image intensity is approximately directly proportional to 1/T 1 for that range. Significant differences were identified in the width of the distributions of the post-contrast T 1 values between lobular and ductal carcinomas (P contrast T 1 values, potentially related to their infiltrative growth pattern. This work has demonstrated the feasibility of fat-suppressed T 1 measurements as a tool for clinical studies. The

  2. Objectivity And Moral Relativism

    OpenAIRE

    Magni, Sergio Filippo

    2017-01-01

    The relativity of morals has usually been taken as an argument against the objectivity of ethics. However, a more careful analysis can show that there are forms of moral objectivism which have relativistic implications, and that moral relativism can be compatible with the objectivity of ethics. Such an objectivity is not always in contrast to moral relativism and it is possible to be relativists without having to give up the claim of objectivity in ethics

  3. Dual-energy CT in the assessment of mediastinal lymph nodes: Comparative study of virtual non-contrast and true non-contrast images

    International Nuclear Information System (INIS)

    Yoo, Seon Young; Kim, Yoo Kyung; Cho, Hyun Hae; Choi, Mi Joo; Shim, Sung Shine; Lee, Jeong Kyong; Baek, Seung Yon

    2013-01-01

    To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0.612). The mean absolute difference was 7.8 ± 7.6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65.2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (κ value, 0.335). Five of 16 nodes (31.3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0.455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0.245). VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.

  4. Dual-energy CT in the assessment of mediastinal lymph nodes: Comparative study of virtual non-contrast and true non-contrast images

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seon Young; Kim, Yoo Kyung; Cho, Hyun Hae; Choi, Mi Joo; Shim, Sung Shine; Lee, Jeong Kyong; Baek, Seung Yon [School of Medicine, Ewha Womans University, Seou (Korea, Republic of)

    2013-06-15

    To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0.612). The mean absolute difference was 7.8 ± 7.6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65.2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (κ value, 0.335). Five of 16 nodes (31.3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0.455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0.245). VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.

  5. Dual-energy CT in the assessment of mediastinal lymph nodes: comparative study of virtual non-contrast and true non-contrast images.

    Science.gov (United States)

    Yoo, Seon Young; Kim, Yookyung; Cho, Hyun Hae; Choi, Mi Joo; Shim, Sung Shine; Lee, Jeong Kyong; Baek, Seung Yon

    2013-01-01

    To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0.612). The mean absolute difference was 7.8 ± 7.6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65.2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (κ value, 0.335). Five of 16 nodes (31.3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0.455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0.245). VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.

  6. Prospective randomized study of contrast reaction management curricula: Computer-based interactive simulation versus high-fidelity hands-on simulation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Carolyn L., E-mail: wangcl@uw.edu [Department of Radiology, University of Washington, Box 357115, 1959 NE Pacific Street, Seattle, WA 98195-7115 (United States); Schopp, Jennifer G.; Kani, Kimia [Department of Radiology, University of Washington, Box 357115, 1959 NE Pacific Street, Seattle, WA 98195-7115 (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, 500 University Drive, Hershey, PA 17033 (United States); Zaidi, Sadaf; Hippe, Dan S.; Paladin, Angelisa M.; Bush, William H. [Department of Radiology, University of Washington, Box 357115, 1959 NE Pacific Street, Seattle, WA 98195-7115 (United States)

    2013-12-01

    Purpose: We developed a computer-based interactive simulation program for teaching contrast reaction management to radiology trainees and compared its effectiveness to high-fidelity hands-on simulation training. Materials and methods: IRB approved HIPAA compliant prospective study of 44 radiology residents, fellows and faculty who were randomized into either the high-fidelity hands-on simulation group or computer-based simulation group. All participants took separate written tests prior to and immediately after their intervention. Four months later participants took a delayed written test and a hands-on high-fidelity severe contrast reaction scenario performance test graded on predefined critical actions. Results: There was no statistically significant difference between the computer and hands-on groups’ written pretest, immediate post-test, or delayed post-test scores (p > 0.6 for all). Both groups’ scores improved immediately following the intervention (p < 0.001). The delayed test scores 4 months later were still significantly higher than the pre-test scores (p ≤ 0.02). The computer group's performance was similar to the hands-on group on the severe contrast reaction simulation scenario test (p = 0.7). There were also no significant differences between the computer and hands-on groups in performance on the individual core competencies of contrast reaction management during the contrast reaction scenario. Conclusion: It is feasible to develop a computer-based interactive simulation program to teach contrast reaction management. Trainees that underwent computer-based simulation training scored similarly on written tests and on a hands-on high-fidelity severe contrast reaction scenario performance test as those trained with hands-on high-fidelity simulation.

  7. Prospective randomized study of contrast reaction management curricula: Computer-based interactive simulation versus high-fidelity hands-on simulation

    International Nuclear Information System (INIS)

    Wang, Carolyn L.; Schopp, Jennifer G.; Kani, Kimia; Petscavage-Thomas, Jonelle M.; Zaidi, Sadaf; Hippe, Dan S.; Paladin, Angelisa M.; Bush, William H.

    2013-01-01

    Purpose: We developed a computer-based interactive simulation program for teaching contrast reaction management to radiology trainees and compared its effectiveness to high-fidelity hands-on simulation training. Materials and methods: IRB approved HIPAA compliant prospective study of 44 radiology residents, fellows and faculty who were randomized into either the high-fidelity hands-on simulation group or computer-based simulation group. All participants took separate written tests prior to and immediately after their intervention. Four months later participants took a delayed written test and a hands-on high-fidelity severe contrast reaction scenario performance test graded on predefined critical actions. Results: There was no statistically significant difference between the computer and hands-on groups’ written pretest, immediate post-test, or delayed post-test scores (p > 0.6 for all). Both groups’ scores improved immediately following the intervention (p < 0.001). The delayed test scores 4 months later were still significantly higher than the pre-test scores (p ≤ 0.02). The computer group's performance was similar to the hands-on group on the severe contrast reaction simulation scenario test (p = 0.7). There were also no significant differences between the computer and hands-on groups in performance on the individual core competencies of contrast reaction management during the contrast reaction scenario. Conclusion: It is feasible to develop a computer-based interactive simulation program to teach contrast reaction management. Trainees that underwent computer-based simulation training scored similarly on written tests and on a hands-on high-fidelity severe contrast reaction scenario performance test as those trained with hands-on high-fidelity simulation

  8. Evaluation of fast highly undersampled contrast-enhanced MR angiography (sparse CE-MRA) in intracranial applications - initial study

    International Nuclear Information System (INIS)

    Gratz, Marcel; Quick, Harald H.; Schlamann, Marc; Goericke, Sophia; Maderwald, Stefan

    2017-01-01

    To assess the image quality of sparsely sampled contrast-enhanced MR angiography (sparse CE-MRA) providing high spatial resolution and whole-head coverage. Twenty-three patients scheduled for contrast-enhanced MR imaging of the head, (N = 19 with intracranial pathologies, N = 9 with vascular diseases), were included. Sparse CE-MRA at 3 Tesla was conducted using a single dose of contrast agent. Two neuroradiologists independently evaluated the data regarding vascular visibility and diagnostic value of overall 24 parameters and vascular segments on a 5-point ordinary scale (5 = very good, 1 = insufficient vascular visibility). Contrast bolus timing and the resulting arterio-venous overlap was also evaluated. Where available (N = 9), sparse CE-MRA was compared to intracranial Time-of-Flight MRA. The overall rating across all patients for sparse CE-MRA was 3.50 ± 1.07. Direct influence of the contrast bolus timing on the resulting image quality was observed. Overall mean vascular visibility and image quality across different features was rated good to intermediate (3.56 ± 0.95). The average performance of intracranial Time-of-Flight was rated 3.84 ± 0.87 across all patients and 3.54 ± 0.62 across all features. Sparse CE-MRA provides high-quality 3D MRA with high spatial resolution and whole-head coverage within short acquisition time. Accurate contrast bolus timing is mandatory. (orig.)

  9. Evaluation of fast highly undersampled contrast-enhanced MR angiography (sparse CE-MRA) in intracranial applications - initial study

    Energy Technology Data Exchange (ETDEWEB)

    Gratz, Marcel; Quick, Harald H. [University of Duisburg-Essen, Erwin L. Hahn Institute for MR Imaging, Essen (Germany); University Hospital Essen, High Field and Hybrid MR Imaging, Essen (Germany); Schlamann, Marc [University Hospital Giessen and Marburg GmbH, Neuroradiology, Giessen (Germany); University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Goericke, Sophia [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Maderwald, Stefan [University of Duisburg-Essen, Erwin L. Hahn Institute for MR Imaging, Essen (Germany)

    2017-03-15

    To assess the image quality of sparsely sampled contrast-enhanced MR angiography (sparse CE-MRA) providing high spatial resolution and whole-head coverage. Twenty-three patients scheduled for contrast-enhanced MR imaging of the head, (N = 19 with intracranial pathologies, N = 9 with vascular diseases), were included. Sparse CE-MRA at 3 Tesla was conducted using a single dose of contrast agent. Two neuroradiologists independently evaluated the data regarding vascular visibility and diagnostic value of overall 24 parameters and vascular segments on a 5-point ordinary scale (5 = very good, 1 = insufficient vascular visibility). Contrast bolus timing and the resulting arterio-venous overlap was also evaluated. Where available (N = 9), sparse CE-MRA was compared to intracranial Time-of-Flight MRA. The overall rating across all patients for sparse CE-MRA was 3.50 ± 1.07. Direct influence of the contrast bolus timing on the resulting image quality was observed. Overall mean vascular visibility and image quality across different features was rated good to intermediate (3.56 ± 0.95). The average performance of intracranial Time-of-Flight was rated 3.84 ± 0.87 across all patients and 3.54 ± 0.62 across all features. Sparse CE-MRA provides high-quality 3D MRA with high spatial resolution and whole-head coverage within short acquisition time. Accurate contrast bolus timing is mandatory. (orig.)

  10. Semiconducting polymer dot as a highly effective contrast agent for photoacoustic imaging

    Science.gov (United States)

    Yuan, Zhen; Zhang, Jian

    2018-02-01

    In this study, we developed a novel PIID-DTBT based semiconducting polymer dots (Pdots) that have broad and strong optical absorption in the visible-light region (500 nm - 700 nm). Gold nanoparticles (GNPs) and gold nanorods (GNRs) that have been verified as an excellent photoacoustic contrast agent were compared with Pdots based on photoacoustic imaging method. Both ex vivo and in vivo experiment demonstrated Pdots have a better photoacoustic conversion efficiency at 532 nm than GNPs and similar photoacoustic performance with GNRs at 700 nm at the same mass concentration. Our work demonstrates the great potential of Pdots as a highly effective contrast agent for precise localization of lesions relative to the blood vessels based on photoacoustic tomography imaging.

  11. High contrast enhancement aspect of dynamic computed tomography with arterial infusion - DCT-AI

    International Nuclear Information System (INIS)

    Kato, Seishi; Iwasaki, Naoya; Matsumura, Yoshimitsu; Kuramae, Shigeru; Mishiro, Tadashi

    1983-01-01

    Dynamic computed tomography was performed on 112 cases possibly having hepatic tumors with intraarterial infusion of undiluted contrast into a selectively placed catheter following angiographies. Our dynamic program could evaluate not only early phase of enhancement but also late phase up to 120 sec. Reconstructed views from early scans and magnified views were very useful to evaluate minute sequential changes. Hepatic masses less than 5 cm in size were found in thirty-one cases. Patterns of tumor enhancement and time-density curves have been analysed to correlate them with histology. Four types of tumor enhancement were noted: (1) homogeneous (2) patchy (3) mottled (4) ringed. Characteristic changes were observed in hepatocellular carcinoma - HCC - (mostly mottled) and haemangioma (mostly patchy). The former was divided in two groups reflecting the cellular maturity. The metastatic tumor could be enhanced in a ringed form with dendritic pattern of supplying vascularities in some cases. To support the use of undiluted contrast and to investigate the diagnostic efficacy of high contrast enhancement, experiments were performed by taking transaxial views of an acrylic phantom immersed in different concentrations of contrast. Analysis of CT images taken at different HU values ranging from 0 to 450 demonstrated that the higher the concentration of contrast, the better the spatial resolution was. Also larger magnification could be expected by using higher concentration of contrast. Although our Dynamic Computed Tomography with Arterial Infusion of Contrast still has drawbacks and limited indications, we advocate it as a better way of enhancement to detect and evaluate the hepatic masses, which sometimes elude the examiner's grasp with conventional way of enhancement. (author)

  12. Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner

    International Nuclear Information System (INIS)

    Müller, Mark; Yaroshenko, Andre; Velroyen, Astrid; Tapfer, Arne; Bech, Martin; Pauwels, Bart; Bruyndonckx, Peter; Sasov, Alexander; Pfeiffer, Franz

    2015-01-01

    In the field of biomedical X-ray imaging, novel techniques, such as phase-contrast and dark-field imaging, have the potential to enhance the contrast and provide complementary structural information about a specimen. In this paper, a first prototype of a preclinical X-ray phase-contrast CT scanner based on a Talbot-Lau interferometer is characterized. We present a study of the contrast-to-noise ratios for attenuation and phase-contrast images acquired with the prototype scanner. The shown results are based on a series of projection images and tomographic data sets of a plastic phantom in phase and attenuation-contrast recorded with varying acquisition settings. Subsequently, the signal and noise distribution of different regions in the phantom were determined. We present a novel method for estimation of contrast-to-noise ratios for projection images based on the cylindrical geometry of the phantom. Analytical functions, representing the expected signal in phase and attenuation-contrast for a circular object, are fitted to individual line profiles of the projection data. The free parameter of the fit function is used to estimate the contrast and the goodness of the fit is determined to assess the noise in the respective signal. The results depict the dependence of the contrast-to-noise ratios on the applied source voltages, the number of steps of the phase stepping routine, and the exposure times for an individual step. Moreover, the influence of the number of projection angles on the image quality of CT slices is investigated. Finally, the implications for future imaging purposes with the scanner are discussed

  13. X-ray phase-contrast tomography for high-spatial-resolution zebrafish muscle imaging

    Science.gov (United States)

    Vågberg, William; Larsson, Daniel H.; Li, Mei; Arner, Anders; Hertz, Hans M.

    2015-11-01

    Imaging of muscular structure with cellular or subcellular detail in whole-body animal models is of key importance for understanding muscular disease and assessing interventions. Classical histological methods for high-resolution imaging methods require excision, fixation and staining. Here we show that the three-dimensional muscular structure of unstained whole zebrafish can be imaged with sub-5 μm detail with X-ray phase-contrast tomography. Our method relies on a laboratory propagation-based phase-contrast system tailored for detection of low-contrast 4-6 μm subcellular myofibrils. The method is demonstrated on 20 days post fertilization zebrafish larvae and comparative histology confirms that we resolve individual myofibrils in the whole-body animal. X-ray imaging of healthy zebrafish show the expected structured muscle pattern while specimen with a dystrophin deficiency (sapje) displays an unstructured pattern, typical of Duchenne muscular dystrophy. The method opens up for whole-body imaging with sub-cellular detail also of other types of soft tissue and in different animal models.

  14. Comparison of low-contrast detectability of computed radiography and screen/ film mammography systems

    International Nuclear Information System (INIS)

    Noriah Jamal; Kwan-Hoong Ng; McLean, D.; McLean, D.

    2008-01-01

    The objective of this study is to compare low-contrast detectability of computed radiography (CR) and screen/ film (SF) mammography systems. The Nijimegen contrast detail test object (CDMAM type 3.4) was imaged at 28 kV, in automatic exposure control mode separately. Six medical imaging physicists read each CDMAM phantom image. Contrast detail curves were plotted to compare low-contrast detectability of CR (soft copy and hard copy) and SF mammography systems. Effect of varying exposure parameters, namely kV, object position inside the breast phantom, and entrance surface exposure (ESE) on the contrast detail curve were also investigated using soft copy CR. The significance of the difference in contrast between CR and SF, and for each exposure parameter, was tested using non-parametric Kruskal-Wallis test. The low-contrast detectability of the CR (soft copy and hard copy) system was found to be not significantly different to that of the SF system (p> 0.05, Kruskal-Wallis test).For CR soft copy, no significant relationship (p>0.05, Kruskal-Wallis test) was seen for variation of kV, object position inside the breast phantom and ESE. This indicates that CR is comparable with SF for useful detection and visualization of low-contrast objects such as small low-contrast areas corresponding to breast pathology. (Author)

  15. Phase contrast image segmentation using a Laue analyser crystal

    International Nuclear Information System (INIS)

    Kitchen, Marcus J; Paganin, David M; Lewis, Robert A; Pavlov, Konstantin M; Uesugi, Kentaro; Allison, Beth J; Hooper, Stuart B

    2011-01-01

    Dual-energy x-ray imaging is a powerful tool enabling two-component samples to be separated into their constituent objects from two-dimensional images. Phase contrast x-ray imaging can render the boundaries between media of differing refractive indices visible, despite them having similar attenuation properties; this is important for imaging biological soft tissues. We have used a Laue analyser crystal and a monochromatic x-ray source to combine the benefits of both techniques. The Laue analyser creates two distinct phase contrast images that can be simultaneously acquired on a high-resolution detector. These images can be combined to separate the effects of x-ray phase, absorption and scattering and, using the known complex refractive indices of the sample, to quantitatively segment its component materials. We have successfully validated this phase contrast image segmentation (PCIS) using a two-component phantom, containing an iodinated contrast agent, and have also separated the lungs and ribcage in images of a mouse thorax. Simultaneous image acquisition has enabled us to perform functional segmentation of the mouse thorax throughout the respiratory cycle during mechanical ventilation.

  16. Phase-contrast X-ray computed tomography of non-formalin fixed biological objects

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tohoru E-mail: ttakeda@md.tsukuba.ac.jp; Momose, Atsushi; Wu, Jin; Zeniya, Tsutomu; Yu Quanwen; Thet Thet Lwin; Itai, Yuji

    2001-07-21

    Using a monolithic X-ray interferometer having the view size of 25 mmx25 mm, phase-contrast X-ray CT (PCCT) was performed for non-formalin fixed livers of two normal rats and a rabbit transplanted with VX-2 cancer. PCCT images of liver and cancer lesions resembled well those obtained by formalin fixed samples.

  17. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    International Nuclear Information System (INIS)

    Ogunlade, Olumide; Beard, Paul

    2015-01-01

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  18. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    Energy Technology Data Exchange (ETDEWEB)

    Ogunlade, Olumide, E-mail: o.ogunlade@ucl.ac.uk; Beard, Paul [Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT (United Kingdom)

    2015-01-15

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  19. Edge Contrast of the FLAIR Hyperintense Region Predicts Survival in Patients with High-Grade Gliomas following Treatment with Bevacizumab.

    Science.gov (United States)

    Bahrami, N; Piccioni, D; Karunamuni, R; Chang, Y-H; White, N; Delfanti, R; Seibert, T M; Hattangadi-Gluth, J A; Dale, A; Farid, N; McDonald, C R

    2018-04-05

    Treatment with bevacizumab is standard of care for recurrent high-grade gliomas; however, monitoring response to treatment following bevacizumab remains a challenge. The purpose of this study was to determine whether quantifying the sharpness of the fluid-attenuated inversion recovery hyperintense border using a measure derived from texture analysis-edge contrast-improves the evaluation of response to bevacizumab in patients with high-grade gliomas. MRIs were evaluated in 33 patients with high-grade gliomas before and after the initiation of bevacizumab. Volumes of interest within the FLAIR hyperintense region were segmented. Edge contrast magnitude for each VOI was extracted using gradients of the 3D FLAIR images. Cox proportional hazards models were generated to determine the relationship between edge contrast and progression-free survival/overall survival using age and the extent of surgical resection as covariates. After bevacizumab, lower edge contrast of the FLAIR hyperintense region was associated with poorer progression-free survival ( P = .009) and overall survival ( P = .022) among patients with high-grade gliomas. Kaplan-Meier curves revealed that edge contrast cutoff significantly stratified patients for both progression-free survival (log-rank χ 2 = 8.3, P = .003) and overall survival (log-rank χ 2 = 5.5, P = .019). Texture analysis using edge contrast of the FLAIR hyperintense region may be an important predictive indicator in patients with high-grade gliomas following treatment with bevacizumab. Specifically, low FLAIR edge contrast may partially reflect areas of early tumor infiltration. This study adds to a growing body of literature proposing that quantifying features may be important for determining outcomes in patients with high-grade gliomas. © 2018 by American Journal of Neuroradiology.

  20. Intravenous contrast injection significantly affects bone mineral density measured on CT

    NARCIS (Netherlands)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J. J.; Mohamed Hoesein, Firdaus A A; de Jong, Pim A.

    OBJECTIVE: The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. METHODS: One hundred and fifty-two patients (99 without and

  1. Phase-contrast X-ray computed tomography of non-formalin fixed biological objects

    Science.gov (United States)

    Takeda, Tohoru; Momose, Atsushi; Wu, Jin; Zeniya, Tsutomu; Yu, Quanwen; Thet-Thet-Lwin; Itai, Yuji

    2001-07-01

    Using a monolithic X-ray interferometer having the view size of 25 mm×25 mm, phase-contrast X-ray CT (PCCT) was performed for non-formalin fixed livers of two normal rats and a rabbit transplanted with VX-2 cancer. PCCT images of liver and cancer lesions resembled well those obtained by formalin fixed samples.

  2. Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and in Vivo Evaluation

    NARCIS (Netherlands)

    V. Daeichin (Verya); T. van Rooij (Tom); I. Skachkov (Ilya); B. Ergin (Bulent); P. Specht (Patricia); A.A.P. Lima (Alexandre ); C. Ince (Can); J.G. Bosch (Hans); A.F.W. van der Steen (Ton); N. de Jong (Nico); K. Kooiman (Klazina)

    2017-01-01

    textabstractAlthough high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited

  3. Semi-analytical approach for guided mode resonance in high-index-contrast photonic crystal slab: TE polarization.

    Science.gov (United States)

    Yang, Yi; Peng, Chao; Li, Zhengbin

    2013-09-09

    In high-contrast (HC) photonic crystals (PC) slabs, the high-order coupling is so intense that it is indispensable for analyzing the guided mode resonance (GMR) effect. In this paper, a semi-analytical approach is proposed for analyzing GMR in HC PC slabs with TE-like polarization. The intense high-order coupling is included by using a convergent recursive procedure. The reflection of radiative waves at high-index-contrast interfaces is also considered by adopting a strict Green's function for multi-layer structures. Modal properties of interest like band structure, radiation constant, field profile are calculated, agreeing well with numerical finite-difference time-domain simulations. This analysis is promising for the design and optimization of various HC PC devices.

  4. Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging : In Vitro and in Vivo Evaluation

    NARCIS (Netherlands)

    Daeichin, Verya; van Rooij, Tom; Skachkov, Ilya; Ergin, Bulent; Specht, Patricia A.C.; Lima, Alexandre; Ince, Can; Bosch, Johan G.; van der Steen, A.F.W.; de Jong, N.; Kooiman, Klazina

    2017-01-01

    Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially

  5. Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation

    NARCIS (Netherlands)

    Daeichin, Verya; van Rooij, Tom; Skachkov, Ilya; Ergin, Bulent; Specht, Patricia A. C.; Lima, Alexandre; Ince, Can; Bosch, Johan G.; van der Steen, Antonius F. W.; de Jong, Nico; Kooiman, Klazina

    2017-01-01

    Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially available

  6. Electron acceleration via high contrast laser interacting with submicron clusters

    International Nuclear Information System (INIS)

    Zhang Lu; Chen Liming; Wang Weiming; Yan Wenchao; Yuan Dawei; Mao Jingyi; Wang Zhaohua; Liu Cheng; Shen Zhongwei; Li Yutong; Dong Quanli; Lu Xin; Ma Jinglong; Wei Zhiyi; Faenov, Anatoly; Pikuz, Tatiana; Li Dazhang; Sheng Zhengming; Zhang Jie

    2012-01-01

    We experimentally investigated electron acceleration from submicron size argon clusters-gas target irradiated by a 100 fs, 10 TW laser pulses having a high-contrast. Electron beams are observed in the longitudinal and transverse directions to the laser propagation. The measured energy of the longitudinal electron reaches 600 MeV and the charge of the electron beam in the transverse direction is more than 3 nC. A two-dimensional particle-in-cell simulation of the interaction has been performed and it shows an enhancement of electron charge by using the cluster-gas target.

  7. Polarization-independent high-index contrast grating and its fabrication tolerances

    DEFF Research Database (Denmark)

    Ikeda, Kazuhiro; Takeuchi, Kazuma; Takayose, Kentaro

    2013-01-01

    also investigated the fabrication tolerances of the structure and found that, assuming careful optimizations of electron beam lithography for the precise grating width and dry-etching for the vertical sidewall, the suggested polarization-independent HCG can be fabricated using standard technologies.......A polarization-independent, high-index contrast grating (HCG) with a single layer of cross stripes allowing simple fabrication is proposed. Since the cross stripes structure can be suspended in air by selectively wet-etching the layer below, all the layers can be grown at once when implemented...

  8. Photoacoustic contrast imaging of biological tissues with nanodiamonds fabricated for high near-infrared absorbance.

    Science.gov (United States)

    Zhang, Ti; Cui, Huizhong; Fang, Chia-Yi; Su, Long-Jyun; Ren, Shenqiang; Chang, Huan-Cheng; Yang, Xinmai; Forrest, M Laird

    2013-02-01

    Radiation-damaged nanodiamonds (DNDs) are potentially ideal optical contrast agents for photoacoustic (PA) imaging in biological tissues due to their low toxicity and high optical absorbance. PA imaging contrast agents have been limited to quantum dots and gold particles, since most existing carbon-based nanoparticles, including fluorescent nanodiamonds, do not have sufficient optical absorption in the near-infrared (NIR) range. A new DND by He+ ion beam irradiation with very high NIR absorption was synthesized. These DNDs produced a 71-fold higher PA signal on a molar basis than similarly dimensioned gold nanorods, and 7.1 fmol of DNDs injected into rodents could be clearly imaged 3 mm below the skin surface with PA signal enhancement of 567% using an 820-nm laser wavelength.

  9. Design of a compact high-energy setup for x-ray phase-contrast imaging

    Science.gov (United States)

    Schüttler, Markus; Yaroshenko, Andre; Bech, Martin; Potdevin, Guillaume; Malecki, Andreas; Chabior, Michael; Wolf, Johannes; Tapfer, Arne; Meiser, Jan; Kunka, Danays; Amberger, Maximilian; Mohr, Jürgen; Pfeiffer, Franz

    2014-03-01

    The main shortcoming of conventional biomedical x-ray imaging is the weak soft-tissue contrast caused by the small differences in the absorption coefficients between different materials. This issue can be addressed by x-ray phasesensitive imaging approaches, e.g. x-ray Talbot-Lau grating interferometry. The advantage of the three-grating Talbot-Lau approach is that it allows to acquire x-ray phase-contrast and dark-field images with a conventional lab source. However, through the introduction of the grating interferometer some constraints are imposed on the setup geometry. In general, the grating pitch and the mean x-ray energy determine the setup dimensions. The minimal length of the setup increases linearly with energy and is proportional to p2, where p is the grating pitch. Thus, a high-energy (100 keV) compact grating-based setup for x-ray imaging can be realized only if gratings with aspect-ratio of approximately 300 and a pitch of 1-2 μm were available. However, production challenges limit the availability of such gratings. In this study we consider the use of non-binary phase-gratings as means of designing a more compact grating interferometer for phase-contrast imaging. We present simulation and experimental data for both monochromatic and polychromatic case. The results reveal that phase-gratings with triangular-shaped structures yield visibilities that can be used for imaging purposes at significantly shorter distances than binary gratings. This opens the possibility to design a high-energy compact setup for x-ray phase-contrast imaging. Furthermore, we discuss different techniques to achieve triangular-shaped phase-shifting structures.

  10. Low osmolar (non-ionic) contrast media versus high osmolar (ionic) contrast media in intravenous urography and enhanced computerized tomography: a cost-effectiveness analysis.

    Science.gov (United States)

    Wangsuphachart, S

    1991-12-01

    The cost-effectiveness of three alternative policies for the use of intravenous contrast media for urography and enhanced computerized tomography (CT) are analyzed. Alternative #1 is to use high osmolar contrast media (HOCM) in all patients, the historical policy. Alternative #2 is to replace it with low osmolar contrast media (LOCM) in all patients. Alternative #3 is to use LOCM only in the high risk patients. Data on the 6,242 patients who underwent intravenous urography and enhanced CT at the Department of Radiology, Chulalongkorn Hospital in 1989 were used. Both societal and hospital viewpoints were analyzed. The incremental cost-effectiveness (ICE) between #2 and #1 was 26,739 Baht (US$1,070) per healthy day saved (HDS), while the ICE between #3 and #1 was 12,057 Baht (US$482) per HDS. For fatal cases only, ICE between #2 and #1 was 35,111 Baht (US$1,404) per HDS, while the ICE between #3 and #1 was 18,266 Baht (US$731) per HDS. The incremental cost (IC) per patient was 2,341 Baht (US$94) and 681 Baht (US$27) respectively. For the hospital viewpoint the ICE between #2 and #1 was 13,744 (US$550) and between #3 and #1 was 6,127 Baht (US$245) per HDS. The IC per patient was 1,203 Baht (US$48) and 346 Baht (US$14), respectively. From the sensitivity analysis, #3 should be used if the LOCM price is reduced more than 75% (equal to 626 Baht or less) and more than 80% of the patients are able to pay for the contrast media.

  11. NEW TECHNIQUES FOR HIGH-CONTRAST IMAGING WITH ADI: THE ACORNS-ADI SEEDS DATA REDUCTION PIPELINE

    International Nuclear Information System (INIS)

    Brandt, Timothy D.; Turner, Edwin L.; McElwain, Michael W.; Grady, C. A.; Abe, L.; Brandner, W.; Feldt, M.; Henning, T.; Carson, J.; Egner, S.; Golota, T.; Guyon, O.; Hayano, Y.; Hayashi, S.; Ishii, M.; Goto, M.; Hashimoto, J.; Hayashi, M.; Iye, M.; Hodapp, K. W.

    2013-01-01

    We describe Algorithms for Calibration, Optimized Registration, and Nulling the Star in Angular Differential Imaging (ACORNS-ADI), a new, parallelized software package to reduce high-contrast imaging data, and its application to data from the SEEDS survey. We implement several new algorithms, including a method to register saturated images, a trimmed mean for combining an image sequence that reduces noise by up to ∼20%, and a robust and computationally fast method to compute the sensitivity of a high-contrast observation everywhere on the field of view without introducing artificial sources. We also include a description of image processing steps to remove electronic artifacts specific to Hawaii2-RG detectors like the one used for SEEDS, and a detailed analysis of the Locally Optimized Combination of Images (LOCI) algorithm commonly used to reduce high-contrast imaging data. ACORNS-ADI is written in python. It is efficient and open-source, and includes several optional features which may improve performance on data from other instruments. ACORNS-ADI requires minimal modification to reduce data from instruments other than HiCIAO. It is freely available for download at www.github.com/t-brandt/acorns-adi under a Berkeley Software Distribution (BSD) license.

  12. Optical polarization of high-energy BL Lacertae objects

    Science.gov (United States)

    Hovatta, T.; Lindfors, E.; Blinov, D.; Pavlidou, V.; Nilsson, K.; Kiehlmann, S.; Angelakis, E.; Fallah Ramazani, V.; Liodakis, I.; Myserlis, I.; Panopoulou, G. V.; Pursimo, T.

    2016-12-01

    Context. We investigate the optical polarization properties of high-energy BL Lac objects using data from the RoboPol blazar monitoring program and the Nordic Optical Telescope. Aims: We wish to understand if there are differences between the BL Lac objects that have been detected with the current-generation TeV instruments and those objects that have not yet been detected. Methods: We used a maximum-likelihood method to investigate the optical polarization fraction and its variability in these sources. In order to study the polarization position angle variability, we calculated the time derivative of the electric vector position angle (EVPA) change. We also studied the spread in the Stokes Q/I-U/I plane and rotations in the polarization plane. Results: The mean polarization fraction of the TeV-detected BL Lacs is 5%, while the non-TeV sources show a higher mean polarization fraction of 7%. This difference in polarization fraction disappears when the dilution by the unpolarized light of the host galaxy is accounted for. The TeV sources show somewhat lower fractional polarization variability amplitudes than the non-TeV sources. Also the fraction of sources with a smaller spread in the Q/I-U/I plane and a clumped distribution of points away from the origin, possibly indicating a preferred polarization angle, is larger in the TeV than in the non-TeV sources. These differences between TeV and non-TeV samples seem to arise from differences between intermediate and high spectral peaking sources instead of the TeV detection. When the EVPA variations are studied, the rate of EVPA change is similar in both samples. We detect significant EVPA rotations in both TeV and non-TeV sources, showing that rotations can occur in high spectral peaking BL Lac objects when the monitoring cadence is dense enough. Our simulations show that we cannot exclude a random walk origin for these rotations. Conclusions: These results indicate that there are no intrinsic differences in the

  13. Rectal water contrast transvaginal ultrasound versus double-contrast barium enema in the diagnosis of bowel endometriosis

    OpenAIRE

    Jiang, Jipeng; Liu, Ying; Wang, Kun; Wu, Xixiang; Tang, Ying

    2017-01-01

    Objectives The aim of study was to compare the accuracy between rectal water contrast transvaginal ultrasound (RWC-TVS) and double-contrast barium enema (DCBE) in evaluating the bowel endometriosis presence as well as its extent. Design and setting 198 patients at reproductive age with suspicious bowel endometriosis were included. Physicians in two groups specialised at endometriosis performed RWC-TVS as well as DCBE before laparoscopy and both groups were blinded to other groups’ results. Fi...

  14. Electron dose dependence of signal-to-noise ratio, atom contrast and resolution in transmission electron microscope images

    International Nuclear Information System (INIS)

    Lee, Z.; Rose, H.; Lehtinen, O.; Biskupek, J.; Kaiser, U.

    2014-01-01

    In order to achieve the highest resolution in aberration-corrected (AC) high-resolution transmission electron microscopy (HRTEM) images, high electron doses are required which only a few samples can withstand. In this paper we perform dose-dependent AC-HRTEM image calculations, and study the dependence of the signal-to-noise ratio, atom contrast and resolution on electron dose and sampling. We introduce dose-dependent contrast, which can be used to evaluate the visibility of objects under different dose conditions. Based on our calculations, we determine optimum samplings for high and low electron dose imaging conditions. - Highlights: • The definition of dose-dependent atom contrast is introduced. • The dependence of the signal-to-noise ratio, atom contrast and specimen resolution on electron dose and sampling is explored. • The optimum sampling can be determined according to different dose conditions

  15. Contrast-enhanced ultra-high-field liver MRI: A feasibility trial

    Energy Technology Data Exchange (ETDEWEB)

    Umutlu, Lale, E-mail: Lale.Umutlu@uk-essen.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Bitz, Andreas K.; Maderwald, Stefan; Orzada, Stephan; Kinner, Sonja; Kraff, Oliver; Brote, Irina; Ladd, Susanne C.; Schroeder, Tobias; Forsting, Michael; Antoch, Gerald; Ladd, Mark E. [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Quick, Harald H. [Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Institute of Medical Physics, University Nuernberg-Erlangen (Germany); Lauenstein, Thomas C. [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2013-05-15

    The aim of this study was to investigate the feasibility of dynamic contrast-enhanced 7 T MRI of the liver using an eight-channel radiofrequency (RF) transmit/receive body-coil. 16 healthy subjects were examined on a 7 T MR system utilizing a custom-built eight-channel RF body-coil suitable for RF-shimming. The following data were acquired: (1) steady state free precession imaging, (2) T2w turbo spin echo imaging, (3) T1w in and opposed-phase imaging, (4) T1w 3D FLASH images pre-contrast and in arterial, portal-venous and venous phase and (5) a fat-saturated pre- and post-contrast 2D FLASH sequence. Visual evaluation of (1) the delineation of liver vasculature, (2) the overall image quality, and (3) artifact presence and consequent image impairment was performed. SNR of the liver parenchyma was measured for the contrast-enhanced 2D and 3D FLASH sequences. For statistical analysis, a Wilcoxon-Rank Test was used. Best delineation of non-enhanced liver vasculature and overall image quality was found for 2D FLASH MRI, with only slight improvement in vessel conspicuity after the application of contrast media. T2-weighted TSE imaging remained strongly impaired, falling short of diagnostic relevance and precluding a clinical application. Our results demonstrate the feasibility and diagnostic potential of dedicated contrast-enhanced 7 T liver MRI as well as the potential for non-contrast-enhanced angiographic application.

  16. Hydrologic Model Development and Calibration: Contrasting a Single- and Multi-Objective Approach for Comparing Model Performance

    Science.gov (United States)

    Asadzadeh, M.; Maclean, A.; Tolson, B. A.; Burn, D. H.

    2009-05-01

    Hydrologic model calibration aims to find a set of parameters that adequately simulates observations of watershed behavior, such as streamflow, or a state variable, such as snow water equivalent (SWE). There are different metrics for evaluating calibration effectiveness that involve quantifying prediction errors, such as the Nash-Sutcliffe (NS) coefficient and bias evaluated for the entire calibration period, on a seasonal basis, for low flows, or for high flows. Many of these metrics are conflicting such that the set of parameters that maximizes the high flow NS differs from the set of parameters that maximizes the low flow NS. Conflicting objectives are very likely when different calibration objectives are based on different fluxes and/or state variables (e.g., NS based on streamflow versus SWE). One of the most popular ways to balance different metrics is to aggregate them based on their importance and find the set of parameters that optimizes a weighted sum of the efficiency metrics. Comparing alternative hydrologic models (e.g., assessing model improvement when a process or more detail is added to the model) based on the aggregated objective might be misleading since it represents one point on the tradeoff of desired error metrics. To derive a more comprehensive model comparison, we solved a bi-objective calibration problem to estimate the tradeoff between two error metrics for each model. Although this approach is computationally more expensive than the aggregation approach, it results in a better understanding of the effectiveness of selected models at each level of every error metric and therefore provides a better rationale for judging relative model quality. The two alternative models used in this study are two MESH hydrologic models (version 1.2) of the Wolf Creek Research basin that differ in their watershed spatial discretization (a single Grouped Response Unit, GRU, versus multiple GRUs). The MESH model, currently under development by Environment

  17. Are the senses enough for sense? Early high-level feedback shapes our comprehension of multisensory objects

    Directory of Open Access Journals (Sweden)

    Lorina eNaci

    2012-09-01

    Full Text Available A key question in cognitive neuroscience is how the brain combines low-level features processed in remote sensory cortices to represent meaningful multisensory objects in our everyday environment. Models of visual object processing typically assume a feedforward cascade through the hierarchically organized ventral stream. We contrasted this feedforward view with an alternate hypothesis in which object processing is viewed as an interactive, feedforward and feedback process. We found that higher-order regions in anterior temporal and inferior prefrontal cortex performed audio-visual integration 100ms earlier than a sensory-driven region in the posterior occipital cortex, and were modulated by semantic variables (congruency, from as early as 50-100ms. We propose that the brain represents familiar and complex multisensory objects through early interactivity between higher-order and sensory-driven regions. This interactivity may underpin the enhanced behavioural performance reported for semantically congruent audio-visual objects.

  18. Probing ultrafast dynamics of solid-density plasma generated by high-contrast intense laser pulses

    Science.gov (United States)

    Jana, Kamalesh; Blackman, David R.; Shaikh, Moniruzzaman; Lad, Amit D.; Sarkar, Deep; Dey, Indranuj; Robinson, Alex P. L.; Pasley, John; Ravindra Kumar, G.

    2018-01-01

    We present ultrafast dynamics of solid-density plasma created by high-contrast (picosecond contrast ˜10-9), high-intensity (˜4 × 1018 W/cm2) laser pulses using time-resolved pump-probe Doppler spectrometry. Experiments show a rapid rise in blue-shift at early time delay (2-4.3 ps) followed by a rapid fall (4.3-8.3 ps) and then a slow rise in blue-shift at later time delays (>8.3 ps). Simulations show that the early-time observations, specifically the absence of any red-shifting of the reflected probe, can only be reproduced if the front surface is unperturbed by the laser pre-pulse at the moment that the high intensity pulse arrives. A flexible diagnostic which is capable of diagnosing the presence of low-levels of pre-plasma formation would be useful for potential applications in laser-produced proton and ion production, such as cancer therapy and security imaging.

  19. Running Improves Pattern Separation during Novel Object Recognition.

    Science.gov (United States)

    Bolz, Leoni; Heigele, Stefanie; Bischofberger, Josef

    2015-10-09

    Running increases adult neurogenesis and improves pattern separation in various memory tasks including context fear conditioning or touch-screen based spatial learning. However, it is unknown whether pattern separation is improved in spontaneous behavior, not emotionally biased by positive or negative reinforcement. Here we investigated the effect of voluntary running on pattern separation during novel object recognition in mice using relatively similar or substantially different objects.We show that running increases hippocampal neurogenesis but does not affect object recognition memory with 1.5 h delay after sample phase. By contrast, at 24 h delay, running significantly improves recognition memory for similar objects, whereas highly different objects can be distinguished by both, running and sedentary mice. These data show that physical exercise improves pattern separation, independent of negative or positive reinforcement. In sedentary mice there is a pronounced temporal gradient for remembering object details. In running mice, however, increased neurogenesis improves hippocampal coding and temporally preserves distinction of novel objects from familiar ones.

  20. High-contrast imaging of mycobacterium tuberculosis using third-harmonic generation microscopy

    Science.gov (United States)

    Kim, Bo Ram; Lee, Eungjang; Park, Seung-Han

    2015-07-01

    Nonlinear optical microcopy has become an important tool in investigating biomaterials due to its various advantages such as label-free imaging capabilities. In particular, it has been shown that third-harmonic generation (THG) signals can be produced at interfaces between an aqueous medium (e.g. cytoplasm, interstitial fluid) and a mineralized lipidic surface. In this work, we have demonstrated that label-free high-contrast THG images of the mycobacterium tuberculosis can be obtained using THG microscopy.

  1. Spatio-Temporal Saliency Perception via Hypercomplex Frequency Spectral Contrast

    Directory of Open Access Journals (Sweden)

    Zhiqiang Tian

    2013-03-01

    Full Text Available Salient object perception is the process of sensing the salient information from the spatio-temporal visual scenes, which is a rapid pre-attention mechanism for the target location in a visual smart sensor. In recent decades, many successful models of visual saliency perception have been proposed to simulate the pre-attention behavior. Since most of the methods usually need some ad hoc parameters or high-cost preprocessing, they are difficult to rapidly detect salient object or be implemented by computing parallelism in a smart sensor. In this paper, we propose a novel spatio-temporal saliency perception method based on spatio-temporal hypercomplex spectral contrast (HSC. Firstly, the proposed HSC algorithm represent the features in the HSV (hue, saturation and value color space and features of motion by a hypercomplex number. Secondly, the spatio-temporal salient objects are efficiently detected by hypercomplex Fourier spectral contrast in parallel. Finally, our saliency perception model also incorporates with the non-uniform sampling, which is a common phenomenon of human vision that directs visual attention to the logarithmic center of the image/video in natural scenes. The experimental results on the public saliency perception datasets demonstrate the effectiveness of the proposed approach compared to eleven state-of-the-art approaches. In addition, we extend the proposed model to moving object extraction in dynamic scenes, and the proposed algorithm is superior to the traditional algorithms.

  2. Enhanced renal image contrast by ethanol fixation in phase-contrast X-ray computed tomography.

    Science.gov (United States)

    Shirai, Ryota; Kunii, Takuya; Yoneyama, Akio; Ooizumi, Takahito; Maruyama, Hiroko; Lwin, Thet Thet; Hyodo, Kazuyuki; Takeda, Tohoru

    2014-07-01

    Phase-contrast X-ray imaging using a crystal X-ray interferometer can depict the fine structures of biological objects without the use of a contrast agent. To obtain higher image contrast, fixation techniques have been examined with 100% ethanol and the commonly used 10% formalin, since ethanol causes increased density differences against background due to its physical properties and greater dehydration of soft tissue. Histological comparison was also performed. A phase-contrast X-ray system was used, fitted with a two-crystal X-ray interferometer at 35 keV X-ray energy. Fine structures, including cortex, tubules in the medulla, and the vessels of ethanol-fixed kidney could be visualized more clearly than that of formalin-fixed tissues. In the optical microscopic images, shrinkage of soft tissue and decreased luminal space were observed in ethanol-fixed kidney; and this change was significantly shown in the cortex and outer stripe of the outer medulla. The ethanol fixation technique enhances image contrast by approximately 2.7-3.2 times in the cortex and the outer stripe of the outer medulla; the effect of shrinkage and the physical effect of ethanol cause an increment of approximately 78% and 22%, respectively. Thus, the ethanol-fixation technique enables the image contrast to be enhanced in phase-contrast X-ray imaging.

  3. Iodinated contrast media nephrotoxicity. Nephrotoxicite des produits de contraste iodes

    Energy Technology Data Exchange (ETDEWEB)

    Meyrier, A. (Hopital Avicenne, 93 - Bobigny (France))

    1994-01-01

    In the late seventies, iodinated contrast agents (ICA) were considered to be a major cause of acute iatrogenic renal failure. Over the last decade new contrast agents have been synthesized, nonionic and less hyperosmolar. The incidence of acute renal failure due to ICAs, varies from 3.7 to 70% of cases according to the series, with an average figure of 10.2%. The pathophysiology of ICA nephrotoxicity was mainly studied in laboratory animal models. Three main factors are involved in an inducing ICA-mediated decrease in glomerular filtration rate: reduction of the renal plasma flow, a direct cytotoxic effect on renal tubular cells and erythrocyte alteration leading to intra-renal sludge. Excluding dysglobulinemias with urinary excretion of immunoglobulin light chains, which represent a special case of maximum nephrotoxicity, 4 main risk factors of renal toxicity have been identified in nondiabetic subjects: previous renal failure with serum creatinine levels greater than 140 [mu]mol per liter, extracellular dehydration, age over 60 and use of high doses of ICA and/or repeated ICA injections before serum creatinine levels return to baseline. Preventive measures for avoiding ICA nephrotoxicity are threefold: maintain or restore adequate hydration with saline infusion, stop NSAID treatment several days before ICA administration, and allow a 5 day interval before repeating contrast media injections. New, nonionic and moderately hyperosmolar contrast agents appear to be much less nephrotoxic than conventional ICAs in laboratory animals and in high-risk patients. It is advisable to select such contrast media for investigating high-risk patients. This approach was recently substantiated in well designed, randomized clinical studies which included more than 2 000 patients. (author).

  4. High frequency nonlinear scattering from a micrometer to submicrometer sized lipid encapsulated contrast agent

    NARCIS (Netherlands)

    Goertz, David E.; Frijlink, Martijn E.; de Jong, N.; van der Steen, A.F.W.

    2006-01-01

    An experimental lipid encapsulated contrast agent comprised substantially of micrometer to submicrometer diameter bubbles was evaluated for its capacity to produce nonlinear scattering in response to high transmit frequencies. Agent characterization experiments were conducted at transmit frequencies

  5. Restoration of the contrast of cerebral blood flows by the spatial deconvolution method

    International Nuclear Information System (INIS)

    Compingt, D.L.; Philippon, B.L.

    1982-01-01

    The measurement of regional cerebral blood flows (rCBF) with a gamma camera during xenon-133 inhalation necessitates collimators with high efficiency. Their spatial resolutions are weak: on the images given by a F.W.H.M. collimator (25 mm to 5 cm depth of water), the contrast restoration method by the ponctual dispersion function (P.D.F.) is used. The convolution product (Image)=(Object)*(P.D.F.) is resolved by a bidimensional Fast Fourier Transform treatment. The high frequencies are eliminated by a progressive filtration. The rCBF is calculated with Obrist's method. The Initial Slope Index is only used. A rCBF image with the calculator is also realized. The numerical values are compared with the normal treatment (N) without contrast restoration and after restoration. 22 patients are so treated after severe cerebral strokes. The hemispheric average of the flows according to the 2 treatments is unchanged (difference: 1.1%). The contrast between higher and lower flow areas is increasing by 73% after contrast restoration (significant difference: p [fr

  6. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  7. Current Status and Future Prospects of "J-KAREN" — High Contrast, High Intensity Laser for Studying Relativistic Laser-Matter Interactions

    Science.gov (United States)

    Kiriyama, Hiromitsu; Mori, Michiaki; Okada, Hajime; Shimomura, Takuya; Nakai, Yoshiki; Tanoue, Manabu; Kondo, Shuji; Kanazawa, Shuhei; Yogo, Akifumi; Sagisaka, Akito; Ogura, Koichi; Hayashi, Yukio; Sakaki, Hironao; Pirozhkov, Alexander S.; Kotaki, Hideyuki; Fukuda, Yuji; Nishiuchi, Mamiko; Kando, Masaki; Bulanov, Sergei V.; Yamagiwa, Mitsuru; Kondo, Kiminori; Sugiyama, Akira; Bolton, Paul R.

    We present the design and characterization of a high-contrast, petawatt-class Ti:sapphire chirped-pulse amplification (CPA) laser system. Two saturable absorbers and low-gain optical parametric chirped-pulse amplification (OPCPA) preamplifier in the double CPA laser chain have improved the temporal contrast to 1.4 × 1012 on the subnanosecond time scale at 70 terawatt level. Final uncompressed broadband pulse energy is 28 J, indicating the potential for reaching peak power near 600 terawatt. We also discuss the going upgrade to over petawatt level at a 0.1 Hz repetition rate briefly.

  8. Guideline adherence for identification and hydration of high-risk hospital patients for contrast-induced nephropathy.

    NARCIS (Netherlands)

    Schilp, J.; Blok, C. de; Langelaan, M.; Spreeuwenberg, P.; Wagner, C.

    2014-01-01

    Background: Contrast-induced nephropathy (CIN) is a common cause of acute renal failure in hospital patients. To prevent CIN, identification and hydration of high-risk patients is important. Prevention of CIN by hydration of high-risk patients was one of the themes to be implemented in the Dutch

  9. Guideline adherence for identification and hydration of high-risk hospital patients for contrast-induced nephropathy

    NARCIS (Netherlands)

    Schilp, J.; de Blok, C.; Langelaan, M.; Spreeuwenberg, P.; Wagner, C.

    2014-01-01

    Background: Contrast-induced nephropathy (CIN) is a common cause of acute renal failure in hospital patients. To prevent CIN, identification and hydration of high-risk patients is important. Prevention of CIN by hydration of high-risk patients was one of the themes to be implemented in the Dutch

  10. Choice of intravenous contrast material for CT

    International Nuclear Information System (INIS)

    Cohen, M.D.; Herman, E.; Herron, D.; White, S.T.; Smith, J.A.; Cory, D.A.

    1989-01-01

    For CT, minor side effects (e.g., nausea, vomiting, pain) following intravenous administration of contrast medium may degrade image quality by causing patient motion or by delaying scanning. The objective of this study was to see if nonionic contrast agents offer advantages in reducing the incidence of such side effects. One hundred five pediatric patients randomly received iohexol (Omnipaque), Iopamidol (Isovue), or diatrizoate sodium (Hypaque). Contrast medium was given in doses of 2 mL/kg body weight (300 mg of iodine per milliliter). The results are presented in the paper

  11. ARTIFICIAL INCOHERENT SPECKLES ENABLE PRECISION ASTROMETRY AND PHOTOMETRY IN HIGH-CONTRAST IMAGING

    Energy Technology Data Exchange (ETDEWEB)

    Jovanovic, N.; Guyon, O.; Pathak, P.; Kudo, T. [National Astronomical Observatory of Japan, Subaru Telescope, 650 North A’Ohoku Place, Hilo, HI, 96720 (United States); Martinache, F. [Observatoire de la Cote d’Azur, Boulevard de l’Observatoire, F-06304 Nice (France); Hagelberg, J., E-mail: jovanovic.nem@gmail.com [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States)

    2015-11-10

    State-of-the-art coronagraphs employed on extreme adaptive optics enabled instruments are constantly improving the contrast detection limit for companions at ever-closer separations from the host star. In order to constrain their properties and, ultimately, compositions, it is important to precisely determine orbital parameters and contrasts with respect to the stars they orbit. This can be difficult in the post-coronagraphic image plane, as by definition the central star has been occulted by the coronagraph. We demonstrate the flexibility of utilizing the deformable mirror in the adaptive optics system of the Subaru Coronagraphic Extreme Adaptive Optics system to generate a field of speckles for the purposes of calibration. Speckles can be placed up to 22.5 λ/D from the star, with any position angle, brightness, and abundance required. Most importantly, we show that a fast modulation of the added speckle phase, between 0 and π, during a long science integration renders these speckles effectively incoherent with the underlying halo. We quantitatively show for the first time that this incoherence, in turn, increases the robustness and stability of the adaptive speckles, which will improve the precision of astrometric and photometric calibration procedures. This technique will be valuable for high-contrast imaging observations with imagers and integral field spectrographs alike.

  12. Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Aschoff, Philip; Plathow, Christian; Lichy, Matthias P.; Claussen, Claus D.; Pfannenberg, Christina; Beyer, Thomas; Erb, Gunter; Oeksuez, Mehmet Oe.

    2012-01-01

    State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of 18 F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications. (orig.)

  13. Reflective and refractive objects for mixed reality.

    Science.gov (United States)

    Knecht, Martin; Traxler, Christoph; Winklhofer, Christoph; Wimmer, Michael

    2013-04-01

    In this paper, we present a novel rendering method which integrates reflective or refractive objects into a differential instant radiosity (DIR) framework usable for mixed-reality (MR) applications. This kind of objects are very special from the light interaction point of view, as they reflect and refract incident rays. Therefore they may cause high-frequency lighting effects known as caustics. Using instant-radiosity (IR) methods to approximate these high-frequency lighting effects would require a large amount of virtual point lights (VPLs) and is therefore not desirable due to real-time constraints. Instead, our approach combines differential instant radiosity with three other methods. One method handles more accurate reflections compared to simple cubemaps by using impostors. Another method is able to calculate two refractions in real-time, and the third method uses small quads to create caustic effects. Our proposed method replaces parts in light paths that belong to reflective or refractive objects using these three methods and thus tightly integrates into DIR. In contrast to previous methods which introduce reflective or refractive objects into MR scenarios, our method produces caustics that also emit additional indirect light. The method runs at real-time frame rates, and the results show that reflective and refractive objects with caustics improve the overall impression for MR scenarios.

  14. Effect of microbubble contrast agent during high intensity focused ultrasound ablation on rabbit liver in vivo

    International Nuclear Information System (INIS)

    Chung, Dong Jin; Cho, Se Hyun; Lee, Jae Mun; Hahn, Seong-Tae

    2012-01-01

    Objective: To evaluate the effect of a microbubble contrast agent (SonoVue) during HIFU ablation of a rabbit liver. Materials and methods: HIFU ablations (intensity of 400 W/cm 2 for 4 s, six times, with a 5 s interval between exposures) were performed upon 16 in vivo rabbit livers before and after intravenous injection of a microbubble contrast agent (0.8 ml). A Wilcoxon signed rank test was used to compare mean ablation volume and time required to tissue ablation on real-time US. Shape of ablation and pattern of coagulative necrosis were analyzed by Fisher's exact test. Results: The volume of coagulative necrosis was significantly larger in the combination microbubble and HIFU group than in the HIFU alone group (P < 0.05). Also, time to reach ablation was shorter in the combination microbubble and HIFU group than in the HIFU alone group (P < 0.05). When analyzing the shape of tissue ablation, a pyramidal shape was more prevalently in the HIFU alone group compared to the combination microbubble and HIFU group (P < 0.05). Following an analysis of the pattern of coagulative necrosis, non-cavitary necrosis was found in ten and cavitary necrosis in six of the samples in the combination microbubble and HIFU group. Conversely, non-cavitary necrosis occurred in all 16 samples in the HIFU alone group (P < 0.05). Conclusion: HIFU of in vivo rabbit livers with a microbubble contrast agent produced larger zones of ablation and more cavitary tissue necrosis than without the use of a microbubble contrast agent. Microbubble contrast agents may be useful in tissue ablation by enhancing the treatment effect of HIFU.

  15. The TRIDENT laser at LANL: New “dial-a-contrast” and high-contrast experimental capabilities

    Directory of Open Access Journals (Sweden)

    Flippo K.A.

    2013-11-01

    Full Text Available The Trident laser facility at Los Alamos National Laboratory (LANL has served for more than 20 years as an important tool in inertial confinement fusion (ICF and Material Dynamics research. An energy and power upgrade of the short-pulse beam line to 100J / 200 TW was made in 2007 and contrast improvements have been made continually since. The combination of this powerful new short-pulse beamline with the two flexible long pulse beamlines, and a total of three different target areas, makes Trident a highly flexible and versatile research tool for high energy density laboratory plasma (HEDLP research. The newest “Dial-a-Contrast” (DaC features are described, along with nominal performance of the laser at the presently available highest contrast.

  16. Use of an object model in three dimensional image reconstruction. Application in medical imaging

    International Nuclear Information System (INIS)

    Delageniere-Guillot, S.

    1993-02-01

    Threedimensional image reconstruction from projections corresponds to a set of techniques which give information on the inner structure of the studied object. These techniques are mainly used in medical imaging or in non destructive evaluation. Image reconstruction is an ill-posed problem. So the inversion has to be regularized. This thesis deals with the introduction of a priori information within the reconstruction algorithm. The knowledge is introduced through an object model. The proposed scheme is applied to the medical domain for cone beam geometry. We address two specific problems. First, we study the reconstruction of high contrast objects. This can be applied to bony morphology (bone/soft tissue) or to angiography (vascular structures opacified by injection of contrast agent). With noisy projections, the filtering steps of standard methods tend to smooth the natural transitions of the investigated object. In order to regularize the reconstruction but to keep contrast, we introduce a model of classes which involves the Markov random fields theory. We develop a reconstruction scheme: analytic reconstruction-reprojection. Then, we address the case of an object changing during the acquisition. This can be applied to angiography when the contrast agent is moving through the vascular tree. The problem is then stated as a dynamic reconstruction. We define an evolution AR model and we use an algebraic reconstruction method. We represent the object at a particular moment as an intermediary state between the state of the object at the beginning and at the end of the acquisition. We test both methods on simulated and real data, and we prove how the use of an a priori model can improve the results. (author)

  17. ASSOCIATIONS OF HIGH-REDSHIFT QUASI-STELLAR OBJECTS WITH ACTIVE, LOW-REDSHIFT SPIRAL GALAXIES

    International Nuclear Information System (INIS)

    Burbidge, G.; Napier, W. M.

    2009-01-01

    Following the discovery in the 1960s of radio and optical QSOs it was found that some of them lie very close to low-redshift (z ≤ 0.01) spiral galaxies with separations of ∼<2 arcmin. These were discovered both serendipitously by many observers, and systematically by Arp. They are some of the brightest QSOs in radio and optical wavelengths and are very rare. We have carried out a new statistical analysis of most of those galaxy-QSO pairs and find that the configurations have high statistical significance. We show that gravitational microlensing due to stars or other dark objects in the halos of the galaxies apparently cannot account for the excess. Sampling or identification bias likewise seems unable to explain it. Following this up we selected all ∼4000 QSOs with g ≤ 18 from a catalog of confirmed QSOs in the Sloan Digital Sky Survey, and compared them with various subsets of galaxies from the RC 3 galaxy catalog. In contrast to the earlier results, no significant excess of such QSOs was found around these galaxies. Possible reasons for the discrepancy are discussed.

  18. Perceived Barriers to the Use of High-Fidelity Hands-On Simulation Training for Contrast Reaction Management: Why Programs are Not Using It.

    Science.gov (United States)

    Chinnugounder, Sankar; Hippe, Daniel S; Maximin, Suresh; O'Malley, Ryan B; Wang, Carolyn L

    2015-01-01

    Although subjective and objective benefits of high-fidelity simulation have been reported in medicine, there has been slow adoption in radiology. The purpose of our study was to identify the perceived barriers in the use of high-fidelity hands-on simulation for contrast reaction management training. An IRB exempt 32 questions online web survey was sent to 179 non-military radiology residency program directors listed in the Fellowship and Residency Electronic Interactive Database Access system (FREIDA). Survey questions included the type of contrast reaction management training, cost, time commitment of residents and faculty, and the reasons for not using simulation training. Responses from the survey were summarized as count (percentage), mean ± standard deviation (SD), or median (range). 84 (47%) of 179 programs responded, of which 88% offered CRM training. Most (72%) conducted the CRM training annually while only 4% conducted it more frequently. Didactic lecture was the most frequently used training modality (97%), followed by HFS (30%) and computer-based simulation (CBS) (19%); 5.5% used both HFS and CBS. Of the 51 programs that offer CRM training but do not use HFS, the most common reason reported was insufficient availability (41%). Other reported reasons included cost (33%), no access to simulation centers (33%), lack of trained faculty (27%) and time constraints (27%). Although high-fidelity hands-on simulation training is the best way to reproduce real-life contrast reaction scenarios, many institutions do not provide this training due to constraints such as cost, lack of access or insufficient availability of simulation labs, and lack of trained faculty. As a specialty, radiology needs to better address these barriers at both an institutional and national level. Copyright © 2015 Mosby, Inc. All rights reserved.

  19. High Contrast Coherent Population Trapping Resonances in Cs Vapour Cells with a Simple-Architecture Laser System

    International Nuclear Information System (INIS)

    Liu, Xiaochi

    2013-01-01

    This thesis reports the development of a simple-architecture laser system resonant at 895 nm used for the detection of high-contrast coherent population trapping (CPT) resonances in Cs vapor cells. The laser system combines a distributed feedback-diode (DFB) laser, a pigtailed Mach-Zehnder intensity electro-optic modulator (EOM) driven at 4.596 GHz for the generation of optical sidebands frequency-split by 9.192 GHz and a Michelson delay-line system to produce a bi-chromatic optical field that alternates between right and left circular polarization. This polarization pumping scheme, first proposed by Happer's group in Princeton on K atoms, allows to optically pump a maximum number of Cs atoms into the 0-0 magnetic field insensitive clock transition. Advanced noise reduction techniques were implemented in order to stabilize the laser power, the optical carrier suppression at the output of the EOM and the DFB laser frequency. Using this system, we demonstrated the detection of CPT resonances with a contrast of 80% in cm-scale Cs vapor cells. This contrast was measured to be increased until a saturation effect with the laser power at the expense of the CPT line broadening. To circumvent this issue, we proposed with a simple setup Ramsey spectroscopy of CPT resonances in vapor cells to combine high-contrast and narrow line width of the CPT resonances. In this setup, the EOM is used both for optical sidebands generation and light switch to produce Ramsey interaction. Ramsey fringes of 166 Hz line width with a contrast better than 30% were detected with this setup. This laser system will be in a near future devoted to be used for the development of a high-performance CPT-based atomic clock. (author)

  20. Computer-aided safety systems of industrial high energy objects

    International Nuclear Information System (INIS)

    Topolsky, N.G.; Gordeev, S.G.

    1995-01-01

    Modern objects of fuel and energy, chemical industries are characterized by high power consumption; by presence of large quantities of combustible and explosive substances used in technological processes; by advanced communications of submission systems of initial liquid and gasiform reagents, lubricants and coolants, the products of processing, and wastes of production; by advanced ventilation and pneumatic transport; and by complex control systems of energy, material and information flows. Such objects have advanced infrastructures, including a significant quantity of engineering buildings intended for storage, transportation, and processing of combustible liquids, gasiform fuels and materials, and firm materials. Examples of similar objects are nuclear and thermal power stations, chemical plants, machine-building factories, iron and steel industry enterprises, etc. Many tasks and functions characterizing the problem of fire safety of these objects can be accomplished only upon the development of special Computer-Aided Fire Safety Systems (CAFSS). The CAFSS for these objects are intended to reduce the hazard of disastrous accidents both causing fires and caused by them. The tasks of fire prevention and rescue work of large-scale industrial objects are analyzed within the bounds of the recommended conception. A functional structure of CAFSS with a list of the main subsystems forming a part of its composition has been proposed

  1. Characterisation of a single photon counting pixel system for imaging of low-contrast objects

    CERN Document Server

    Mikulec, B; Dipasquale, G; Schwarz, C; Watt, J

    2001-01-01

    In the framework of the Medipix collaboration the PCC, a single photon counting pixel chip, has been developed with the aim of improving the contrast resolution in medical imaging applications. The PCC consists of a matrix of 64x64 square pixels with 170 mm side length, each pixel comprising a 15 bit counter and a pulse height discriminator. The chip has been bump bonded to equally segmented 200 mm thick SI-LEC GaAs detectors showing a very high absorption energy for X-rays used in diagnostics. An absolute calibration of the system with a radioactive source and a synchrotron beam are described resulting in the value of the test input capacitance of ~24.7 fF. Using this value a full characterisation of the system from electrical measurements is presented. The entire system can reach a minimum threshold of ~2100 e- with ~250e- rms noise. One of the characteristics of the PCC is the possibility to adjust the thresholds of all pixels on a pixel-by-pixel basis with 3-bit precision. The threshold distribution after...

  2. High Relaxivity Gadolinium Hydroxypyridonate-Viral Capsid Conjugates: Nano-sized MRI Contrast Agents

    Energy Technology Data Exchange (ETDEWEB)

    Meux, Susan C.; Datta, Ankona; Hooker, Jacob M.; Botta, Mauro; Francis, Matthew B.; Aime, Silvio; Raymond, Kenneth N.

    2007-08-29

    High relaxivity macromolecular contrast agents based on the conjugation of gadolinium chelates to the interior and exterior surfaces of MS2 viral capsids are assessed. The proton nuclear magnetic relaxation dispersion (NMRD) profiles of the conjugates show up to a five-fold increase in relaxivity, leading to a peak relaxivity (per Gd{sup 3+} ion) of 41.6 mM{sup -1}s{sup -1} at 30 MHz for the internally modified capsids. Modification of the exterior was achieved through conjugation to flexible lysines, while internal modification was accomplished by conjugation to relatively rigid tyrosines. Higher relaxivities were obtained for the internally modified capsids, showing that (1) there is facile diffusion of water to the interior of capsids and (2) the rigidity of the linker attaching the complex to the macromolecule is important for obtaining high relaxivity enhancements. The viral capsid conjugated gadolinium hydroxypyridonate complexes appear to possess two inner-sphere water molecules (q = 2) and the NMRD fittings highlight the differences in the local motion for the internal ({tau}{sub RI} = 440 ps) and external ({tau}{sub RI} = 310 ps) conjugates. These results indicate that there are significant advantages of using the internal surface of the capsids for contrast agent attachment, leaving the exterior surface available for the installation of tissue targeting groups.

  3. A contrast-enhanced ultrasound study of benign and malignant ...

    African Journals Online (AJOL)

    A contrast-enhanced ultrasound study of benign and malignant breast tissue. S Barnard, E Leen, T Cooke, W Angerson. Abstract. Objective. To determine the diagnostic value of haemodynamic contrast-enhanced ultrasound assessment in benign and malignant breast tissue, using histological examination as the reference ...

  4. Continuously tunable photonic fractional Hilbert transformer using a high-contrast germanium-doped silica-on-silicon microring resonator.

    Science.gov (United States)

    Shahoei, Hiva; Dumais, Patrick; Yao, Jianping

    2014-05-01

    We propose and experimentally demonstrate a continuously tunable fractional Hilbert transformer (FHT) based on a high-contrast germanium-doped silica-on-silicon (SOS) microring resonator (MRR). The propagation loss of a high-contrast germanium-doped SOS waveguide can be very small (0.02 dB/cm) while the lossless bend radius can be less than 1 mm. These characteristics lead to the fabrication of an MRR with a high Q-factor and a large free-spectral range (FSR), which is needed to implement a Hilbert transformer (HT). The SOS MRR is strongly polarization dependent. By changing the polarization direction of the input signal, the phase shift introduced at the center of the resonance spectrum is changed. The tunable phase shift at the resonance wavelength can be used to implement a tunable FHT. A germanium-doped SOS MRR with a high-index contrast of 3.8% is fabricated. The use of the fabricated MRR for the implementation of a tunable FHT with tunable orders at 1, 0.85, 0.95, 1.05, and 1.13 for a Gaussian pulse with the temporal full width at half-maximum of 80 ps is experimentally demonstrated.

  5. Dynamics and structure of self-generated magnetics fields on solids following high contrast, high intensity laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Albertazzi, B. [LULI, École Polytechnique, CNRS, CEA, UPMC, 91128 Palaiseau (France); INRS-EMT, 1650 bd L. Boulet, J3X1S2, Varennes, Québec (Canada); Graduate School of Engineering, University of Osaka, Suita, Osaka 565-087 (Japan); Chen, S. N.; Fuchs, J., E-mail: julien.fuchs@polytechnique.fr [LULI, École Polytechnique, CNRS, CEA, UPMC, 91128 Palaiseau (France); Institute of Applied Physics, 46 Ulyanov Street, 603950 Nizhny Novgorod (Russian Federation); Antici, P. [INRS-EMT, 1650 bd L. Boulet, J3X1S2, Varennes, Québec (Canada); Dept. SBAI, Universita di Roma “La Sapienza,” Via A. Scarpa 14, 00161 Rome (Italy); Böker, J.; Swantusch, M.; Willi, O. [Institut für Laser-und Plasmaphysik, Heinrich-Heine-Universität, Düsseldorf (Germany); Borghesi, M. [School of Mathematics and Physics, The Queen' s University, Belfast (United Kingdom); Breil, J.; Feugeas, J. L.; Nicolaï, Ph.; Tikhonchuk, V. T.; D' Humières, E. [CELIA, University of Bordeaux - CNRS - CEA, 33405 Talence (France); Dervieux, V.; Nakatsutsumi, M.; Romagnagni, L. [LULI, École Polytechnique, CNRS, CEA, UPMC, 91128 Palaiseau (France); Lancia, L. [Dept. SBAI, Universita di Roma “La Sapienza,” Via A. Scarpa 14, 00161 Rome (Italy); Shepherd, R. [LLNL, East Av., Livermore, California 94550 (United States); Sentoku, Y. [Department of Physics, University of Nevada, Reno, Nevada 89557-0058 (United States); Starodubtsev, M. [Institute of Applied Physics, 46 Ulyanov Street, 603950 Nizhny Novgorod (Russian Federation); and others

    2015-12-15

    The dynamics of self-generated magnetic B-fields produced following the interaction of a high contrast, high intensity (I > 10{sup 19 }W cm{sup −2}) laser beam with thin (3 μm thick) solid (Al or Au) targets is investigated experimentally and numerically. Two main sources drive the growth of B-fields on the target surfaces. B-fields are first driven by laser-generated hot electron currents that relax over ∼10–20 ps. Over longer timescales, the hydrodynamic expansion of the bulk of the target into vacuum also generates B-field induced by non-collinear gradients of density and temperature. The laser irradiation of the target front side strongly localizes the energy deposition at the target front, in contrast to the target rear side, which is heated by fast electrons over a much larger area. This induces an asymmetry in the hydrodynamic expansion between the front and rear target surfaces, and consequently the associated B-fields are found strongly asymmetric. The sole long-lasting (>30 ps) B-fields are the ones growing on the target front surface, where they remain of extremely high strength (∼8–10 MG). These B-fields have been recently put by us in practical use for focusing laser-accelerated protons [B. Albertazzi et al., Rev. Sci. Instrum. 86, 043502 (2015)]; here we analyze in detail their dynamics and structure.

  6. Optimization of contrast-enhanced spectral mammography depending on clinical indication.

    Science.gov (United States)

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-10-01

    The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality.

  7. Isotropic differential phase contrast microscopy for quantitative phase bio-imaging.

    Science.gov (United States)

    Chen, Hsi-Hsun; Lin, Yu-Zi; Luo, Yuan

    2018-05-16

    Quantitative phase imaging (QPI) has been investigated to retrieve optical phase information of an object and applied to biological microscopy and related medical studies. In recent examples, differential phase contrast (DPC) microscopy can recover phase image of thin sample under multi-axis intensity measurements in wide-field scheme. Unlike conventional DPC, based on theoretical approach under partially coherent condition, we propose a new method to achieve isotropic differential phase contrast (iDPC) with high accuracy and stability for phase recovery in simple and high-speed fashion. The iDPC is simply implemented with a partially coherent microscopy and a programmable thin-film transistor (TFT) shield to digitally modulate structured illumination patterns for QPI. In this article, simulation results show consistency of our theoretical approach for iDPC under partial coherence. In addition, we further demonstrate experiments of quantitative phase images of a standard micro-lens array, as well as label-free live human cell samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Contrast Media: Are There Differences in Nephrotoxicity among Contrast Media?

    Science.gov (United States)

    2014-01-01

    Iodinated contrast agents are usually classified based upon their osmolality—high, low, and isosmolar. Iodinated contrast agents are also nephrotoxic in some but not all patients resulting in loss of glomerular filtration rate. Over the past 30 years, nephrotoxicity has been linked to osmolality although the precise mechanism underlying such a link has been elusive. Improvements in our understanding of the pathogenesis of nephrotoxicity and prospective randomized clinical trials have attempted to further explore the relationship between osmolality and nephrotoxicity. In this review, the basis for our current understanding that there are little if any differences in nephrotoxic potential between low and isosmolar contrast media will be detailed using data from clinical studies. PMID:24587997

  9. Improvement of observer performance during fluoroscopy by local adaptive contrast enhancement

    International Nuclear Information System (INIS)

    Gould, R.G.; Demas, B.E.; Maroney, T.P.

    1988-01-01

    The ability of a video processor (FluoroVision FV-1), which performs two-dimensional locally adaptive contrast enhancement, to improve the detection of a low-contrast object was evaluated by means of receiver operating characteristic (ROC) curves. Three independent observers viewed a videotape of 50 fluoroscopic images of a varied background, in which a test object was present in 25. Each observer viewed the tape under four conditions: (1) no processing, (2) temporal noise reduction (gaussian weighted time averaging, (3) contrast enhancement, and (4) both noise reduction and contrast enhancement. The results were that detection was significantly improved by the locally adaptive contrast enhancement. Noise reduction did not significantly improve performance, probably because washer detection was limited by background contrast variations as well as noise and because only a small amount of noise reduction was used. The authors conclude that the processing device is potentially valuable in improving the quality of clinical fluoroscopic images

  10. High-contrast imager for Complex Aperture Telescopes (HiCAT): testbed design and coronagraph developments

    Science.gov (United States)

    N'Diaye, Mamadou; Choquet, E.; Pueyo, L.; Elliot, E.; Perrin, M. D.; Wallace, J.; Anderson, R. E.; Carlotti, A.; Groff, T. D.; Hartig, G. F.; Kasdin, J.; Lajoie, C.; Levecq, O.; Long, C.; Macintosh, B.; Mawet, D.; Norman, C. A.; Shaklan, S.; Sheckells, M.; Sivaramakrishnan, A.; Soummer, R.

    2014-01-01

    We present a new high-contrast imaging testbed designed to provide complete solutions for wavefront sensing and control and starlight suppression with complex aperture telescopes (NASA APRA; Soummer PI). This includes geometries with central obstruction, support structures, and/or primary mirror segmentation. Complex aperture telescopes are often associated with large telescope designs, which are considered for future space missions. However, these designs makes high-contrast imaging challenging because of additional diffraction features in the point spread function. We present a novel optimization approach for the testbed optical and opto-mechanical design that minimizes the impact of both phase and amplitude errors from the wave propagation of testbed optics surface errors. This design approach allows us to define the specification for the bench optics, which we then compare to the manufactured parts. We discuss the testbed alignment and first results. We also present our coronagraph design for different testbed pupil shapes (AFTA or ATLAST), which involves a new method for the optimization of Apodized Pupil Lyot Coronagraphs (APLC).

  11. CT of multiple sclerosis: reassessment of delayed scanning with high doses of contrast material

    International Nuclear Information System (INIS)

    Spiegel, S.M.; Vinuela, F.; Fox, A.J.; Pelz, D.M.

    1985-01-01

    A prospective study involving 87 patients was carried out to evaluate the necessity for a high dose of contrast material in addition to delayed computed tomographic (CT) scanning for optimal detection of the lesions of multiple sclerosis in the brain. In patients with either clinically definite multiple sclerosis or laboratory-supported definite multiple sclerosis, CT scans were obtained with a uniform protocol. Lesions consistent with multiple sclerosis were demonstrated on the second scan in 54 patients. In 36 of these 54 patients, the high-dose delayed scan added information. These results are quite similar to those of a previous study from this institution using different patients, in whom the second scan was obtained immediately after the bolus injection of contrast material containing 40 g of organically bound iodine. The lack of real difference in the results of the two studies indicate that the increased dose, not just the delay in scanning, is necessary for a proper study

  12. Transient analysis of electromagnetic wave interactions on high-contrast scatterers using volume electric field integral equation

    KAUST Repository

    Sayed, Sadeed Bin

    2014-07-01

    A marching on-in-time (MOT)-based time domain volume electric field integral equation (TD-VEFIE) solver is proposed for accurate and stable analysis of electromagnetic wave interactions on high-contrast scatterers. The stability is achieved using band-limited but two-sided (non-causal) temporal interpolation functions and an extrapolation scheme to cast the time marching into a causal form. The extrapolation scheme is designed to be highly accurate for oscillating and exponentially decaying fields, hence it accurately captures the physical behavior of the resonant modes that are excited inside the dielectric scatterer. Numerical results demonstrate that the resulting MOT scheme maintains its stability as the number of resonant modes increases with the contrast of the scatterer.

  13. High prevalence of nephrogenic systemic fibrosis in chronic renal failure patients exposed to gadodiamide, a gadolinium-containing magnetic resonance contrast agent

    DEFF Research Database (Denmark)

    Rydahl, Casper; Thomsen, Henrik S; Marckmann, Peter

    2008-01-01

    OBJECTIVE: Nephrogenic systemic fibrosis (NSF) is a serious disease affecting renal failure patients. It may be caused by some gadolinium (Gd)-containing contrast agents, including gadodiamide. The study aimed at estimating the prevalence of NSF after gadodiamide exposure for patients with chronic...

  14. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  15. High-contrast coronagraph performance in the presence of focal plane mask defects

    Science.gov (United States)

    Sidick, Erkin; Shaklan, Stuart; Balasubramanian, Kunjithapatham; Cady, Eric

    2014-08-01

    We have carried out a study of the performance of high-contrast coronagraphs in the presence of mask defects. We have considered the effects of opaque and dielectric particles of various dimensions, as well as systematic mask fabrication errors and the limitations of material properties in creating dark holes. We employ sequential deformable mirrors to compensate for phase and amplitude errors, and show the limitations of this approach in the presence of coronagraph image-mask defects.

  16. Hi shells, supershells, shell-like objects, and ''worms''

    International Nuclear Information System (INIS)

    Heiles, C.

    1984-01-01

    We present photographic representations of the combination of two Hi surveys, so as to eliminate the survey boundaries at Vertical BarbVertical Bar = 10 0 . We also present high-contrast photographs for particular velocities to exhibit weak Hi features. All of these photographs were used to prepare a new list of Hi shells, supershells, and shell-like objects. We discuss the structure of three shell-like objects that are associated with high-velocity gas, and with gas at all velocities that is associated with radio continuum loops I, II, and III. We use spatial filtering to find wiggly gas filaments: ''worms'': crawling away from the galactic plane in the inner Galaxy. The ''worms'' are probably parts of shells that are open at the top; such shells should be good sources of hot gas for the galactic halo

  17. Characteristic density contrasts in the evolution of superclusters. The case of A2142 supercluster

    Science.gov (United States)

    Gramann, Mirt; Einasto, Maret; Heinämäki, Pekka; Teerikorpi, Pekka; Saar, Enn; Nurmi, Pasi; Einasto, Jaan

    2015-09-01

    Context. The formation and evolution of the cosmic web in which galaxy superclusters are the largest relatively isolated objects is governed by a gravitational attraction of dark matter and antigravity of dark energy (cosmological constant). Aims: We study the characteristic density contrasts in the spherical collapse model for several epochs in the supercluster evolution and their dynamical state. Methods: We analysed the density contrasts for the turnaround, future collapse, and zero gravity in different ΛCDM models and applied them to study the dynamical state of the supercluster A2142 with an almost spherical main body, making it a suitable test object to apply a model that assumes sphericity. Results: We present characteristic density contrasts in the spherical collapse model for different cosmological parameters. The analysis of the supercluster A2142 shows that its high-density core has already started to collapse. The zero-gravity line outlines the outer region of the main body of the supercluster. In the course of future evolution, the supercluster may split into several collapsing systems. Conclusions: The various density contrasts presented in our study and applied to the supercluster A2142 offer a promising way to characterise the dynamical state and expected future evolution of galaxy superclusters.

  18. Evaluation of high frequency ultrasound methods and contrast agents for characterising tumor response to anti-angiogenic treatment

    Energy Technology Data Exchange (ETDEWEB)

    Rix, Anne, E-mail: arix@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Lederle, Wiltrud, E-mail: wlederle@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Siepmann, Monica, E-mail: monica.siepmann@rub.de [Department of Medical Engineering, Universitätstraße 150, 44780 Bochum, Ruhr-University Bochum, Bochum (Germany); Fokong, Stanley, E-mail: sfokong@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Behrendt, Florian F., E-mail: fbehrendt@ukaachen.de [Department of Nuclear Medicine, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Bzyl, Jessica, E-mail: jbzyl@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Grouls, Christoph, E-mail: cgrouls@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Kiessling, Fabian, E-mail: fkiessling@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Palmowski, Moritz, E-mail: mpalmowski@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Department of Nuclear Medicine, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany)

    2012-10-15

    Purpose: To compare non-enhanced and contrast-enhanced high-frequency 3D Doppler ultrasound with contrast-enhanced 2D and 3D B-mode imaging for assessing tumor vascularity during antiangiogenic treatment using soft-shell and hard-shell microbubbles. Materials and methods: Antiangiogenic therapy effects (SU11248) on vascularity of subcutaneous epidermoid-carcinoma xenografts (A431) in female CD1 nude mice were investigated longitudinally using non-enhanced and contrast-enhanced 3D Doppler at 25 MHz. Additionally, contrast-enhanced 2D and 3D B-mode scans were performed by injecting hard-shell (poly-butyl-cyanoacrylate-based) and soft-shell (phospholipid-based) microbubbles. Suitability of both contrast agents for high frequency imaging and the sensitivity of the different ultrasound methods to assess early antiangiogenic therapy effects were investigated. Ultrasound data were validated by immunohistology. Results: Hard-shell microbubbles induced higher signal intensity changes in tumors than soft-shell microbubbles in 2D B-mode measurements (424 ± 7 vs. 169 ± 8 A.U.; p < 0.01). In 3D measurements, signals of soft-shell microbubbles were hardly above the background (5.48 ± 4.57 vs. 3.86 ± 2.92 A.U.), while signals from hard-shell microbubbles were sufficiently high (30.5 ± 8.06 A.U). Using hard-shell microbubbles 2D and 3D B-mode imaging depicted a significant decrease in tumor vascularity during antiangiogenic therapy from day 1 on. Using soft-shell microbubbles significant therapy effects were observed at day 4 after therapy in 2D B-mode imaging but could not be detected in the 3D mode. With non-enhanced and contrast-enhanced Doppler imaging significant differences between treated and untreated tumors were found from day 2 on. Conclusion: Hard-shell microbubble-enhanced 2D and 3D B-mode ultrasound achieved highest sensitivity for assessing therapy effects on tumor vascularisation and were superior to B-mode ultrasound with soft-shell microbubbles and to Doppler

  19. Swept source optical coherence tomography of objects with arbitrary reflectivity profiles

    Science.gov (United States)

    Mezgebo, Biniyam; Nagib, Karim; Fernando, Namal; Kordi, Behzad; Sherif, Sherif

    2018-03-01

    Swept Source optical coherence tomography (SS-OCT) has become a well established imaging modality for both medical and industrial diagnostic applications. A cross-sectional SS-OCT image is obtained by applying an inverse discrete Fourier transform (DFT) to axial interferogram measured in the frequency domain (k-space). Fourier inversion of the obtained interferogram typically produces a potentially overlapping conjugate mirror image, whose overlap could be avoided by restricting the object to have its highest reflectivity at its surface. However, this restriction may not be fulfilled when imaging a very thin object that is placed on a highly reflective surface, or imaging an object containing a contrast agent with high reflectivity. In this paper, we show that oversampling of the SS-OCT signal in k-space would overcome the need for such restriction on the object. Our result is demonstrated using SS-OCT images of Axolotl salamander eggs.

  20. Pupil remapping for high contrast astronomy: results from an optical testbed.

    Science.gov (United States)

    Kotani, T; Lacour, S; Perrin, G; Robertson, G; Tuthill, P

    2009-02-02

    The direct imaging and characterization of Earth-like planets is among the most sought-after prizes in contemporary astrophysics, however current optical instrumentation delivers insufficient dynamic range to overcome the vast contrast differential between the planet and its host star. New opportunities are offered by coherent single mode fibers, whose technological development has been motivated by the needs of the telecom industry in the near infrared. This paper presents a new vision for an instrument using coherent waveguides to remap the pupil geometry of the telescope. It would (i) inject the full pupil of the telescope into an array of single mode fibers, (ii) rearrange the pupil so fringes can be accurately measured, and (iii) permit image reconstruction so that atmospheric blurring can be totally removed. Here we present a laboratory experiment whose goal was to validate the theoretical concepts underpinning our proposed method. We successfully confirmed that we can retrieve the image of a simulated astrophysical object (in this case a binary star) though a pupil remapping instrument using single mode fibers.

  1. Measurements of incoherent light and background structure at exo-Earth detection levels in the High Contrast Imaging Testbed

    Science.gov (United States)

    Cady, Eric; Shaklan, Stuart

    2014-08-01

    A major component of the estimation and correction of starlight at very high contrasts is the creation of a dark hole: a region in the vicinity of the core of the stellar point spread function (PSF) where speckles in the PSF wings have been greatly attenuated, up to a factor of 1010 for the imaging of terrestrial exoplanets. At these very high contrasts, removing these speckles requires distinguishing between light from the stellar PSF scattered by instrument imperfections, which may be partially corrected across a broad band using deformable mirrors in the system, from light from other sources which generally may not. These other sources may be external or internal to the instrument (e.g. planets, exozodiacal light), but in either case, their distinguishing characteristic is their inability to interfere coherently with the PSF. In the following we discuss the estimation, structure, and expected origin of this incoherent" signal, primarily in the context of a series of experiments made with a linear band-limited mask in Jan-Mar 2013. We find that the incoherent" signal at moderate contrasts is largely estimation error of the coherent signal, while at very high contrasts it represents a true floor which is stable over week-timescales.

  2. High-Relaxivity MRI Contrast Agents: Where Coordination Chemistry Meets Medical Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Eric J.; Datta, Ankona; Jocher, Christoph J.; Raymond, Kenneth N.

    2008-01-15

    The desire to improve and expand the scope of clinical magnetic resonance imaging (MRI) has prompted the search for contrast agents of higher efficiency. The development of better agents requires consideration of the fundamental coordination chemistry of the gadolinium(III) ion and the parameters that affect its efficacy as a proton relaxation agent. In optimizing each parameter, other practical issues such as solubility and in vivo toxicity must also be addressed, making the attainment of safe, high-relaxivity agents a challenging goal. Here we present recent advances in the field, with an emphasis on the hydroxypyridinone family of Gd{sup III} chelates.

  3. Sodium bicarbonate-based hydration prevents contrast-induced nephropathy: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Tamhane Umesh

    2009-05-01

    Full Text Available Abstract Background Contrast-induced nephropathy is the leading cause of in-hospital acute renal failure. This side effect of contrast agents leads to increased morbidity, mortality, and health costs. Ensuring adequate hydration prior to contrast exposure is highly effective at preventing this complication, although the optimal hydration strategy to prevent contrast-induced nephropathy still remains an unresolved issue. Former meta-analyses and several recent studies have shown conflicting results regarding the protective effect of sodium bicarbonate. The objective of this study was to assess the effectiveness of normal saline versus sodium bicarbonate for prevention of contrast-induced nephropathy. Methods The study searched MEDLINE, EMBASE, Cochrane databases, International Pharmaceutical Abstracts database, ISI Web of Science (until 15 December 2008, and conference proceedings for randomized controlled trials that compared normal saline with sodium bicarbonate-based hydration regimen regarding contrast-induced nephropathy. Random-effects models were used to calculate summary odds ratios. Results A total of 17 trials including 2,633 subjects were pooled. Pre-procedural hydration with sodium bicarbonate was associated with a significant decrease in the rate of contrast-induced nephropathy (odds ratios 0.52; 95% confidence interval 0.34–0.80, P = 0.003. Number needed to treat to prevent one case of contrast-induced nephropathy was 16 (95% confidence interval 10–34. No significant differences in the rates of post-procedure hemodialysis (P = 0.20 or death (P = 0.53 was observed. Conclusion Sodium bicarbonate-based hydration was found to be superior to normal saline in prevention of contrast-induced nephropathy in this updated meta-analysis.

  4. Dose Tc-99m MIBI scintimammography provide more information additive to contrast enhanced MRI in highly suspected breast cancer patients?

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki; Bae, Young Tae

    2000-01-01

    The aim of this study was to investigate whether Tc-99m MIBI scintimammography (SMM) provide more information than contrast enhanced MRI in highly suspected breast cancer patients. This study included 32 breast lesions of 29 highly suspected patients having breast cancer. All patients were performed SMM and contrast enhanced MRI. The SMMs and contrast enhanced MRI were correlated with histopathologic results. Thirty breast lesions were diagnosed malignant diseases and 2 were diagnosed benign diseases. SMM showed 29 true positives (TP), 1 true negative (TN), 1 false positive (FP), and 1 false negative (FN). The sensitivity was 96.6%. Contrast enhanced MRI revealed 24 TP, 0 TN, 1 FP, 3 FN and 4 indeterminate cases. The sensitivity was 88.8%. In the assessment of axillary lymph node metastasis, SMM showed 9 TP, 10 TN, 0 FP, and 3 FN. The sensitivity and specificity were 75% and 100%. Contrast enhanced MRI revealed 6 TP, 9 TN, 1 FP, and 6 FN. The sensitivity and specificity were 50% and 90%. Among 4 indeterminate cases with MRI findings, SMM correctly diagnosed malignant breast diseases in 3 lesions. However, SMM showed false positive in 1 lesion. SMM could correctly diagnosed malignant breast diseases more 5 lesions than contrast enhanced MRI. SMM revealed higher sensitivity in detection of primary breast cancer and axillary LN metastasis than contrast enhanced MRI. SMMs could correctly diagnosed malignant breast diseases even if the MRI showed indeterminate findings. In highly suspected patients having breast cancer, SMM may provide additive information in detection of breast cancer if contrast enhanced MRI showed indeterminate findings but this is to be determined later by large population based study

  5. Dynamic contrast-enhanced MRI in patients with luminal Crohn's disease

    NARCIS (Netherlands)

    Ziech, M. L. W.; Lavini, C.; Caan, M. W. A.; Nio, C. Y.; Stokkers, P. C. F.; Bipat, S.; Ponsioen, C. Y.; Nederveen, A. J.; Stoker, J.

    2012-01-01

    Objectives: To prospectively assess dynamic contrast-enhanced (DCE-)MRI as compared to conventional sequences in patients with luminal Crohn's disease. Methods: Patients with Crohn's disease undergoing MRI and ileocolonoscopy within 1 month had DCE-MRI (3T) during intravenous contrast injection of

  6. In-line phase-contrast stereoscopic X-ray imaging for radiological purposes: An initial experimental study

    International Nuclear Information System (INIS)

    Siegbahn, E.A.; Coan, P.; Zhou, S.-A.; Bravin, A.; Brahme, A.

    2011-01-01

    We report results from a pilot study in which the in-line propagation-based phase-contrast imaging technique is combined with the stereoscopic method. Two phantoms were imaged at several sample-detector distances using monochromatic, 30 keV, X-rays. High contrast- and spatial-resolution phase-contrast stereoscopic pairs of X-ray images were constructed using the anaglyph approach and a vivid stereoscopic effect was demonstrated. On the other hand, images of the same phantoms obtained with a shorter sample-to-detector distance, but otherwise the same experimental conditions (i.e. the same X-ray energy and absorbed radiation dose), corresponding to the conventional attenuation-based imaging mode, hardly revealed stereoscopic effects because of the lower image contrast produced. These results have confirmed our hypothesis that stereoscopic X-ray images of samples with objects composed of low-atomic-number elements are considerably improved if phase-contrast imaging is used. It is our belief that the high-resolution phase-contrast stereoscopic method will be a valuable new medical imaging tool for radiologists and that it will be of help to enhance the diagnostic capability in the examination of patients in future clinical practice, even though further efforts will be needed to optimize the system performance.

  7. Highly stabilized gadolinium chelates functionalized on metal nanoparticles as magnetic resonance imaging contrast agent

    Science.gov (United States)

    Siddiqui, Talha S.

    Magnetic resonance imaging (MRI) is a non-invasive method for imaging and diagnosing tissue damage, organ function and the vascular system. Magnevist(TM) a complex of diethylenetriaminepentaacetic acid (DTPA) and Gd3+ is a clinically approved contrast agent for MRI. A derivative of DTPA was formed by the addition of two cysteine groups (DTPA-L-Cys) through amide linkage. The Gd complex of this ligand bonds with the silver surfaces through the cysteine thiols. GdDTPA-L-Cys was bound to ˜10nm diameter Ag nanoparticles for use as a multifunctional MRI contrast agent. The ligand and complex were characterized by 1H and 13C NMR, ESI-MS and IR spectroscopy. The silver construct was characterized by TEM, TGA and UV-Vis absorption spectra. The per metal complex r1 relaxivity of GdDTPA-L-Cys{Ag} greater than that of Magnavist(TM) with the same molarity for both compounds. The synthesis of a DTPA derivative is described that allows it to bind to silver or gold nanoparticles through a single thiol linkage (DTPASH). The resulting Gd complex, GdDTPASH, was bound to Ag nanoparticles to create a single monolayer on the surface. The construct was further stabilized in buffered solution with the addition of a thiolated PEG chain. The highly stabilized nanoparticle construct delivers a high payload of Gd compelex and is an effective T1 brightening agent. The production of this type of construct opens the way for engineered multimodal MRI contrast agents.

  8. Generation of 25-TW Femtosecond Laser Pulses at 515 nm with Extremely High Temporal Contrast

    Directory of Open Access Journals (Sweden)

    Marco Hornung

    2015-12-01

    Full Text Available We report on the frequency doubling of femtosecond laser pulses at 1030 nm center wavelength generated from the fully diode-pumped laser system POLARIS. The newly generated pulses at a center wavelength of 515 nm have a pulse energy of 3 J with a pulse duration of 120 fs. On the basis of initially ultra-high contrast seed pulses we expect a temporal intensity contrast better 10 17 200 ps before the peak of the main pulse. We analyzed the temporal intensity contrast from milliseconds to femtoseconds with a dynamic range covering more than 20 orders of magnitude. The pulses were focussed with a f/2-focussing parabola resulting in a peak intensity exceeding 10 20 W / cm 2 . The peak power and intensity are to the best of our knowledge the highest values for 515 nm-laser-pulses achieved so far.

  9. Optimization of Broadband Wavefront Correction at the Princeton High Contrast Imaging Laboratory

    Science.gov (United States)

    Groff, Tyler Dean; Kasdin, N.; Carlotti, A.

    2011-01-01

    Wavefront control for imaging of terrestrial planets using coronagraphic techniques requires improving the performance of the wavefront control techniques to expand the correction bandwidth and the size of the dark hole over which it is effective. At the Princeton High Contrast Imaging Laboratory we have focused on increasing the search area using two deformable mirrors (DMs) in series to achieve symmetric correction by correcting both amplitude and phase aberrations. Here we are concerned with increasing the bandwidth of light over which this correction is effective so we include a finite bandwidth into the optimization problem to generate a new stroke minimization algorithm. This allows us to minimize the actuator stroke on the DMs given contrast constraints at multiple wavelengths which define a window over which the dark hole will persist. This windowed stroke minimization algorithm is written in such a way that a weight may be applied to dictate the relative importance of the outer wavelengths to the central wavelength. In order to supply the estimates at multiple wavelengths a functional relationship to a central estimation wavelength is formed. Computational overhead and new experimental results of this windowed stroke minimization algorithm are discussed. The tradeoff between symmetric correction and achievable bandwidth is compared to the observed contrast degradation with wavelength in the experimental results. This work is supported by NASA APRA Grant #NNX09AB96G. The author is also supported under an NESSF Fellowship.

  10. Optimisation of a propagation-based x-ray phase-contrast micro-CT system

    Science.gov (United States)

    Nesterets, Yakov I.; Gureyev, Timur E.; Dimmock, Matthew R.

    2018-03-01

    Micro-CT scanners find applications in many areas ranging from biomedical research to material sciences. In order to provide spatial resolution on a micron scale, these scanners are usually equipped with micro-focus, low-power x-ray sources and hence require long scanning times to produce high resolution 3D images of the object with acceptable contrast-to-noise. Propagation-based phase-contrast tomography (PB-PCT) has the potential to significantly improve the contrast-to-noise ratio (CNR) or, alternatively, reduce the image acquisition time while preserving the CNR and the spatial resolution. We propose a general approach for the optimisation of the PB-PCT imaging system. When applied to an imaging system with fixed parameters of the source and detector this approach requires optimisation of only two independent geometrical parameters of the imaging system, i.e. the source-to-object distance R 1 and geometrical magnification M, in order to produce the best spatial resolution and CNR. If, in addition to R 1 and M, the system parameter space also includes the source size and the anode potential this approach allows one to find a unique configuration of the imaging system that produces the required spatial resolution and the best CNR.

  11. Ultra-high field upper extremity peripheral nerve and non-contrast enhanced vascular imaging.

    Directory of Open Access Journals (Sweden)

    Shailesh B Raval

    Full Text Available The purpose of this study was to explore the efficacy of Ultra-high field [UHF] 7 Tesla [T] MRI as compared to 3T MRI in non-contrast enhanced [nCE] imaging of structural anatomy in the elbow, forearm, and hand [upper extremity].A wide range of sequences including T1 weighted [T1] volumetric interpolate breath-hold exam [VIBE], T2 weighted [T2] double-echo steady state [DESS], susceptibility weighted imaging [SWI], time-of-flight [TOF], diffusion tensor imaging [DTI], and diffusion spectrum imaging [DSI] were optimized and incorporated with a radiofrequency [RF] coil system composed of a transverse electromagnetic [TEM] transmit coil combined with an 8-channel receive-only array for 7T upper extremity [UE] imaging. In addition, Siemens optimized protocol/sequences were used on a 3T scanner and the resulting images from T1 VIBE and T2 DESS were compared to that obtained at 7T qualitatively and quantitatively [SWI was only qualitatively compared]. DSI studio was utilized to identify nerves based on analysis of diffusion weighted derived fractional anisotropy images. Images of forearm vasculature were extracted using a paint grow manual segmentation method based on MIPAV [Medical Image Processing, Analysis, and Visualization].High resolution and high quality signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]-images of the hand, forearm, and elbow were acquired with nearly homogeneous 7T excitation. Measured [performed on the T1 VIBE and T2 DESS sequences] SNR and CNR values were almost doubled at 7T vs. 3T. Cartilage, synovial fluid and tendon structures could be seen with higher clarity in the 7T T1 and T2 weighted images. SWI allowed high resolution and better quality imaging of large and medium sized arteries and veins, capillary networks and arteriovenous anastomoses at 7T when compared to 3T. 7T diffusion weighted sequence [not performed at 3T] demonstrates that the forearm nerves are clearly delineated by fiber tractography. The

  12. Optimization of in-line phase contrast particle image velocimetry using a laboratory x-ray source

    International Nuclear Information System (INIS)

    Ng, I.; Fouras, A.; Paganin, D. M.

    2012-01-01

    Phase contrast particle image velocimetry (PIV) using a laboratory x-ray microfocus source is investigated using a numerical model. Phase contrast images of 75 μm air bubbles, embedded within water exhibiting steady-state vortical flow, are generated under the paraxial approximation using a tungsten x-ray spectrum at 30 kVp. Propagation-based x-ray phase-contrast speckle images at a range of source-object and object-detector distances are generated, and used as input into a simulated PIV measurement. The effects of source-size-induced penumbral blurring, together with the finite dynamic range of the detector, are accounted for in the simulation. The PIV measurement procedure involves using the cross-correlation between temporally sequential speckle images to estimate the transverse displacement field for the fluid. The global error in the PIV reconstruction, for the set of simulations that was performed, suggests that geometric magnification is the key parameter for designing a laboratory-based x-ray phase-contrast PIV system. For the modeled system, x-ray phase-contrast PIV data measurement can be optimized to obtain low error ( 15 μm) of the detector, high geometric magnification (>2.5) is desired, while for large source size system (FWHM > 30 μm), low magnification (<1.5) would be suggested instead. The methods developed in this paper can be applied to optimizing phase-contrast velocimetry using a variety of laboratory x-ray sources.

  13. Real-time underwater object detection based on an electrically scanned high-resolution sonar

    DEFF Research Database (Denmark)

    Henriksen, Lars

    1994-01-01

    The paper describes an approach to real time detection and tracking of underwater objects, using image sequences from an electrically scanned high-resolution sonar. The use of a high resolution sonar provides a good estimate of the location of the objects, but strains the computers on board, beca...

  14. Connecting high-level principles and objectives with practical compliance criteria

    International Nuclear Information System (INIS)

    O'Sullivan, P.

    2008-01-01

    Designed as a Rapporteur if the session, on connecting high-level principles and objectives with practical compliance criteria, the author reports its observations and conclusions concerning the participants speeches. (A.L.B.)

  15. Channels as Objects in Concurrent Object-Oriented Programming

    Directory of Open Access Journals (Sweden)

    Joana Campos

    2011-10-01

    Full Text Available There is often a sort of a protocol associated to each class, stating when and how certain methods should be called. Given that this protocol is, if at all, described in the documentation accompanying the class, current mainstream object-oriented languages cannot provide for the verification of client code adherence against the sought class behaviour. We have defined a class-based concurrent object-oriented language that formalises such protocols in the form of usage types. Usage types are attached to class definitions, allowing for the specification of (1 the available methods, (2 the tests clients must perform on the result of methods, and (3 the object status - linear or shared - all of which depend on the object's state. Our work extends the recent approach on modular session types by eliminating channel operations, and defining the method call as the single communication primitive in both sequential and concurrent settings. In contrast to previous works, we define a single category for objects, instead of distinct categories for linear and for shared objects, and let linear objects evolve into shared ones. We introduce a standard sync qualifier to prevent thread interference in certain operations on shared objects. We formalise the language syntax, the operational semantics, and a type system that enforces by static typing that methods are called only when available, and by a single client if so specified in the usage type. We illustrate the language via a complete example.

  16. Grating-based X-ray phase-contrast tomography of atherosclerotic plaque at high photon energies

    Energy Technology Data Exchange (ETDEWEB)

    Hetterich, Holger; Fill, Sandra [Klinikum der Ludwig-Maximilians-Univ., Muenchen (Germany). Inst. fuer Klinische Radiologie; Herzen, Julia [Technische Univ. Muenchen, Garching (Germany). Physik-Dept. und Inst. fuer Medizintechnik; Helmholtz-Zentrum Geesthacht, Geesthacht (Germany). Zentrum fuer Materialforschung] [and others

    2013-10-01

    Background: Tissue characterization of atherosclerosis by absorption-based imaging methods is limited due to low soft-tissue contrast. Grating-based phase-contrast computed tomography (PC-CT) may become an alternative for plaque assessment if the phase signal can be retrieved at clinically applicable photon energies. The aims of this feasibility study were (i) to characterize arterial vessels at low and high photon energies, (ii) to extract qualitative features and (iii) quantitative phase-contrast Hounsfield units (HU-phase) of plaque components at 53 keV using histopathology as gold standard. Materials and methods: Five human carotid artery specimens underwent grating-based PC-CT using synchrotron radiation of either 23 keV or 53 keV and histological work-up. Specimens without advanced atherosclerosis were used to extract signal criteria of vessel layers. Diseased specimens were screened for important plaque components including fibrous tissue (FT), lipid (LIP), necrotic core (NEC), intraplaque hemorrhage (IPH), inflammatory cell infiltration (INF) and calcifications (CA). Qualitative features as well as quantitative HU-phase were analyzed. Results: Thirty-three regions in 6 corresponding PC-CT scans and histology sections were identified. Healthy samples had the same signal characteristics at 23 keV and 53 keV with bright tunica intima and adventitia and dark media. Plaque components showed differences in signal intensity and texture at 53 keV. Quantitative analysis demonstrated the highest HU-phase of soft plaque in dense FT. Less organized LIP, NEC and INF were associated with lower HU-phase values. The highest HU-phase were measured in CA. Conclusion: PC-CT of atherosclerosis is feasible at high, clinically relevant photon energies and provides detailed information about plaque structure including features of high risk vulnerable plaques. (orig.)

  17. X-ray elastography: Modification of x-ray phase contrast images using ultrasonic radiation pressure

    International Nuclear Information System (INIS)

    Hamilton, Theron J.; Bailat, Claude; Rose-Petruck, Christoph; Diebold, Gerald J.; Gehring, Stephan; Laperle, Christopher M.; Wands, Jack

    2009-01-01

    The high resolution characteristic of in-line x-ray phase contrast imaging can be used in conjunction with directed ultrasound to detect small displacements in soft tissue generated by differential acoustic radiation pressure. The imaging method is based on subtraction of two x-ray images, the first image taken with, and the second taken without the presence of ultrasound. The subtraction enhances phase contrast features and, to a large extent, removes absorption contrast so that differential movement of tissues with different acoustic impedances or relative ultrasonic absorption is highlighted in the image. Interfacial features of objects with differing densities are delineated in the image as a result of both the displacement introduced by the ultrasound and the inherent sensitivity of x-ray phase contrast imaging to density variations. Experiments with ex vivo murine tumors and human tumor phantoms point out a diagnostic capability of the method for identifying tumors.

  18. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  19. [Relevance of contrast ultrasound with microbubbles in vascular medecine].

    Science.gov (United States)

    Erdmann, Andreas; Ney, Barbara; Alatri, Adriano; Calanca, Luca; Mazzolai, Lucia

    2016-12-07

    Application of ultrasound contrast media has become a standard in diagnostic imaging in cardiology and in the characterization of focal lesions in multiple organs, especially of the liver. In the past years there was a growing body of evidence for their usefulness in vascular medicine. The development of contrast media, microbubbles with a stabilizing envelope and filled with gaz, small enough to pass through pulmonary capillaries made real-time imaging of organ perfusion possible. Ultrasound contrast media are rapidly eliminated by exhalation and can safely be administered to patients with renal failure. The objective of this review is to describe the basic principles of ultrasound contrast imaging and to inform about vascular applications of contrast ultrasound.

  20. Multi objective multi refinery optimization with environmental and catastrophic failure effects objectives

    Science.gov (United States)

    Khogeer, Ahmed Sirag

    2005-11-01

    Petroleum refining is a capital-intensive business. With stringent environmental regulations on the processing industry and declining refining margins, political instability, increased risk of war and terrorist attacks in which refineries and fuel transportation grids may be targeted, higher pressures are exerted on refiners to optimize performance and find the best combination of feed and processes to produce salable products that meet stricter product specifications, while at the same time meeting refinery supply commitments and of course making profit. This is done through multi objective optimization. For corporate refining companies and at the national level, Intea-Refinery and Inter-Refinery optimization is the second step in optimizing the operation of the whole refining chain as a single system. Most refinery-wide optimization methods do not cover multiple objectives such as minimizing environmental impact, avoiding catastrophic failures, or enhancing product spec upgrade effects. This work starts by carrying out a refinery-wide, single objective optimization, and then moves to multi objective-single refinery optimization. The last step is multi objective-multi refinery optimization, the objectives of which are analysis of the effects of economic, environmental, product spec, strategic, and catastrophic failure. Simulation runs were carried out using both MATLAB and ASPEN PIMS utilizing nonlinear techniques to solve the optimization problem. The results addressed the need to debottleneck some refineries or transportation media in order to meet the demand for essential products under partial or total failure scenarios. They also addressed how importing some high spec products can help recover some of the losses and what is needed in order to accomplish this. In addition, the results showed nonlinear relations among local and global objectives for some refineries. The results demonstrate that refineries can have a local multi objective optimum that does not

  1. New developments in simulating X-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Peterzol, A.; Berthier, J.; Duvauchelle, P.; Babot, D.; Ferrero, C.

    2007-01-01

    A deterministic algorithm simulating phase contrast (PC) x-ray images for complex 3- dimensional (3D) objects is presented. This algorithm has been implemented in a simulation code named VXI (Virtual X-ray Imaging). The physical model chosen to account for PC technique is based on the Fresnel-Kirchhoff diffraction theory. The algorithm consists mainly of two parts. The first one exploits the VXI ray-tracing approach to compute the object transmission function. The second part simulates the PC image due to the wave front distortion introduced by the sample. In the first part, the use of computer-aided drawing (CAD) models enables simulations to be carried out with complex 3D objects. Differently from the VXI original version, which makes use of an object description via triangular facets, the new code requires a more 'sophisticated' object representation based on Non-Uniform Rational B-Splines (NURBS). As a first step we produce a spatial high resolution image by using a point and monochromatic source and an ideal detector. To simulate the polychromatic case, the intensity image is integrated over the considered x-ray energy spectrum. Then, in order to account for the system spatial resolution properties, the high spatial resolution image (mono or polychromatic) is convolved with the total point spread function of the imaging system under consideration. The results supplied by the presented algorithm are examined with the help of some relevant examples. (authors)

  2. MR angiography of the carotid arteries and intracranial circulation: advantage of a high relaxivity contrast agent

    International Nuclear Information System (INIS)

    Anzalone, N.; Scotti, R.; Iadanza, A.

    2006-01-01

    Several studies have shown the usefulness of contrast-enhanced MR angiography (CE-MRA) for imaging the supraortic vessels, and, as a consequence, it has rapidly become a routine imaging modality. The main advantage over unenhanced techniques is the possibility to acquire larger volumes, allowing demonstration of the carotid artery from its origin to the intracranial portion. Most published studies on CE-MRA of the carotid arteries have been performed with standard Gd-based chelates whose T1 relaxivity values are similar. Recently new gadolinium chelates such as gadobenate dimeglumine (Gd-BOP-TA, MultiHance; Bracco Imaging, Milan, Italy) have been developed which have markedly higher intravascular T1 relaxivity values. When administered at an equivalent dose to that of a standard agent, these newer contrast agents produce significantly greater intravascular signal enhancement. The availability of an appropriate high-relaxivity contrast agent might also help to overcome some of the intrinsic technical problems (e. g. those related to flow) that affect time-of-flight (TOF) and phase contrast (PC) MR angiography of the intracranial vasculature. To avoid the problem of superimposition of veins, ultrafast gradient echo MRA techniques with very short TR and TE have been developed. Although the precise sequence parameters vary between manufacturers, they are basically similar. The choice between performing a time-resolved or high spatial resolution CE-MRA examination depends upon the precise clinical application. The most common applications include the study of cerebral aneurysms, arteriovenous malformations, dural arteriovenous fistulas and dural venous diseases

  3. Contrast, contours and the confusion effect in dazzle camouflage.

    Science.gov (United States)

    Hogan, Benedict G; Scott-Samuel, Nicholas E; Cuthill, Innes C

    2016-07-01

    'Motion dazzle camouflage' is the name for the putative effects of highly conspicuous, often repetitive or complex, patterns on parameters important in prey capture, such as the perception of speed, direction and identity. Research into motion dazzle camouflage is increasing our understanding of the interactions between visual tracking, the confusion effect and defensive coloration. However, there is a paucity of research into the effects of contrast on motion dazzle camouflage: is maximal contrast a prerequisite for effectiveness? If not, this has important implications for our recognition of the phenotype and understanding of the function and mechanisms of potential motion dazzle camouflage patterns. Here we tested human participants' ability to track one moving target among many identical distractors with surface patterns designed to test the influence of these factors. In line with previous evidence, we found that targets with stripes parallel to the object direction of motion were hardest to track. However, reduction in contrast did not significantly influence this result. This finding may bring into question the utility of current definitions of motion dazzle camouflage, and means that some animal patterns, such as aposematic or mimetic stripes, may have previously unrecognized multiple functions.

  4. 80-nm-tunable high-index-contrast subwavelength grating long-wavelength VCSEL: Proposal and numerical simulations

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Mørk, Jesper; Sirbu, Alexei

    2010-01-01

    A widely-tunable single-mode long wavelength vertical-cavity surface-emitting laser structure employing a MEMStunable high-index-contrast subwavelength grating (HCG) is suggested and numerically investigated. A very large 80- nm linear tuning range was obtained as the HCG was actuated by -220 to ...

  5. Optical spatial differentiator based on subwavelength high-contrast gratings

    Science.gov (United States)

    Dong, Zhewei; Si, Jiangnan; Yu, Xuanyi; Deng, Xiaoxu

    2018-04-01

    An optical spatial differentiator based on subwavelength high-contrast gratings (HCGs) is proposed experimentally. The spatial differentiation property of the subwavelength HCG is analyzed by calculating its spatial spectral transfer function based on the periodic waveguide theory. By employing the FDTD solutions, the performance of the subwavelength HCG spatial differentiator was investigated numerically. The subwavelength HCG differentiator with the thickness at the nanoscale was fabricated on the quartz substrate by electron beam lithography and Bosch deep silicon etching. Observed under an optical microscope with a CCD camera, the spatial differentiation of the incident field profile was obtained by the subwavelength HCG differentiator in transmission without Fourier lens. By projecting the images of slits, letter "X," and a cross on the subwavelength HCG differentiator, edge detections of images were obtained in transmission. With the nanoscale HCG structure and simple optical implementation, the proposed optical spatial differentiator provides the prospects for applications in optical computing systems and parallel data processing.

  6. Sub-Hour X-Ray Variability of High-Energy Peaked BL Lacertae Objects

    OpenAIRE

    Bidzina Kapanadze

    2018-01-01

    The study of multi-wavelength flux variability in BL Lacertae objects is very important to discern unstable processes and emission mechanisms underlying their extreme observational features. While the innermost regions of these objects are not accessible from direct observations, we may draw conclusions about their internal structure via the detection of flux variations on various timescales, based on the light-travel argument. In this paper, we review the sub-hour X-ray variability in high-e...

  7. High Contrast Internal and External Coronagraph Masks Produced by Various Techniques

    Science.gov (United States)

    Balasubramanian, Kunjithapatha; Wilson, Daniel; White, Victor; Muller, Richard; Dickie, Matthew; Yee, Karl; Ruiz, Ronald; Shaklan, Stuart; Cady, Eric; Kern, Brian; hide

    2013-01-01

    Masks for high contrast internal and external coronagraphic imaging require a variety of masks depending on different architectures to suppress star light. Various fabrication technologies are required to address a wide range of needs including gradient amplitude transmission, tunable phase profiles, ultra-low reflectivity, precise small scale features, and low-chromaticity. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks, and lab-scale external occulter type masks by various techniques including electron beam, ion beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each. Further development is in progress to produce circular masks of various kinds for obscured aperture telescopes.

  8. Carcinoma of the uterine cervix. High-resolution turbo spin-echo MR imaging with contrast-enhanced dynamic scanning and T2-weighting

    International Nuclear Information System (INIS)

    Abe, Y.; Yamashita, Y.; Namimoto, T.; Takahashi, M.; Katabuchi, H.; Tanaka, N.; Okamura, H.

    1998-01-01

    Purpose: To compare high-resolution contrast-enhanced (Gd-DTPA) dynamic MR imaging with T2-weighted turbo spin-echo (TSE) imaging in the evaluation of uterine cervical carcinoma. Material and Methods: Thirty-two patients with cervical carcinoma underwent MR imaging on a 1.5 T superconductive unit to have the extension of the disease assessed before treatment. A phased-array coil was used in all patients. In 25 patients, surgical confirmation of the diagnosis was obtained after imaging. Radiation therapy was selected for the remaining 7 patients with advanced carcinoma. Qualitative and quantitative image analyses were also performed. Results: The cervical carcinomas showed maximum contrast in the cervical stroma and myometrium in the early dynamic phase. The tumor/cervical-stroma contrast in the early dynamic phase obtained with the T1-weighted TSE technique (contrast-to-noise ratio 22.6) was significantly higher than that obtained in T2-weighted TSE imaging (contrast-to-noise ratio 4.3). In the evaluation of parametrial invasion, the accuracy of T2-weighted imaging was 71.8% and contrast-enhanced dynamic imaging 81.2%. Conclusion: High-resolution contrast-enhanced (Gd-DTPA) dynamic MR imaging in cervical cancer offers improved tumor/cervical-stroma contrast and provides useful information on parametrial invasion. (orig.)

  9. Phase contrast STEM for thin samples: Integrated differential phase contrast.

    Science.gov (United States)

    Lazić, Ivan; Bosch, Eric G T; Lazar, Sorin

    2016-01-01

    It has been known since the 1970s that the movement of the center of mass (COM) of a convergent beam electron diffraction (CBED) pattern is linearly related to the (projected) electrical field in the sample. We re-derive a contrast transfer function (CTF) for a scanning transmission electron microscopy (STEM) imaging technique based on this movement from the point of view of image formation and continue by performing a two-dimensional integration on the two images based on the two components of the COM movement. The resulting integrated COM (iCOM) STEM technique yields a scalar image that is linear in the phase shift caused by the sample and therefore also in the local (projected) electrostatic potential field of a thin sample. We confirm that the differential phase contrast (DPC) STEM technique using a segmented detector with 4 quadrants (4Q) yields a good approximation for the COM movement. Performing a two-dimensional integration, just as for the COM, we obtain an integrated DPC (iDPC) image which is approximately linear in the phase of the sample. Beside deriving the CTFs of iCOM and iDPC, we clearly point out the objects of the two corresponding imaging techniques, and highlight the differences to objects corresponding to COM-, DPC-, and (HA) ADF-STEM. The theory is validated with simulations and we present first experimental results of the iDPC-STEM technique showing its capability for imaging both light and heavy elements with atomic resolution and a good signal to noise ratio (SNR). Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Highly stable polymer coated nano-clustered silver plates: a multimodal optical contrast agent for biomedical imaging

    International Nuclear Information System (INIS)

    Ray, Aniruddha; Mukundan, Ananya; Karamchand, Leshern; Kopelman, Raoul; Xie, Zhixing; Wang, Xueding

    2014-01-01

    Here, we present a new optical contrast agent based on silver nanoplate clusters embedded inside of a polymer nano matrix. Unlike nanosphere clusters, which have been well studied, nanoplate clusters have unique properties due to the different possible orientations of interaction between the individual plates, resulting in a significant broadening of the absorption spectra. These nanoclusters were immobilized inside of a polymer cladding so as to maintain their stability and optical properties under in vivo conditions. The polymer-coated silver nanoplate clusters show a lower toxicity compared to the uncoated nanoparticles. At high nanoparticle concentrations, cell death occurs mostly due to apoptosis. These nanoparticles were used for targeted fluorescence imaging in a rat glioma cell line by incorporating a fluorescent dye into the matrix, followed by conjugation of a tumor targeting an F3 peptide. We further used these nanoparticles as photoacoustic contrast agents in vivo to enhance the contrast of the vasculature structures in a rat ear model. We observed a contrast enhancement of over 90% following the nanoparticle injection. It is also shown that these NPs can serve as efficient contrast agents, with specific targeting abilities for broadband multimodal imaging that are usable for diagnostic applications and that extend into use as therapeutic agents as well. (paper)

  11. In an animal model nephrogenic systemic fibrosis cannot be induced by intraperitoneal injection of high-dose gadolinium based contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Langer, R.D., E-mail: rlanger@uaeu.ac.ae [Faculty of Medicine and Health Sciences (FMHS), United Arab Emirates University, Al Ain (United Arab Emirates); Lorke, D.E. [Florida International University, Miami, FL (United States); Neidl van Gorkom, K.F. [Faculty of Medicine and Health Sciences (FMHS), United Arab Emirates University, Al Ain (United Arab Emirates); Petroianu, G. [Florida International University, Miami, FL (United States); Azimullah, S.; Nurulain, S.M.; Singh, S. [Faculty of Medicine and Health Sciences (FMHS), United Arab Emirates University, Al Ain (United Arab Emirates); Fuchsjäger, M. [Al Ain Hospital, MUV-VAMED, Al Ain (United Arab Emirates)

    2012-10-15

    Aim and objective: Nephrogenic systemic fibrosis (NSF) has been reported in humans to be most likely induced by gadolinium based contrast agents (GBCA), namely by gadodiamide, gadopentetate dimeglumine, and gadoversetamide, rarely by other GBCA. The pathogenesis of NSF remains unclear; different hypotheses are under discussion. The objective of the study is to assess if in the animal model human-like NSF changes can be induced by high-dose, intraperitoneal GBCA injections over four weeks. Materials and methods: After approval by the institutional animal ethics committee, six rats each were randomly assigned to groups, and treated with seven different GBCA. Intraperitoneal (IP) injections – proven in the animal model to be effective – were chosen to prolong the animals’ exposure to the respective GBCA. GBCA doses of previous intravenous (IV) animal studies were applied. After five weeks all rats were sacrificed. Sham controls were treated with IP saline injections, employing the same regimen. Results: No findings comparable with human NSF were observed in all animals after IP treatment with all seven GBCA at daily doses of 2.5 and 5.0 mmol/kg body weight (BW). No histopathological abnormalities of all examined organs were noted. Weight loss was stated in weeks three and four with GBCA injections at doses of 5.0 mmol/kg BW, but rats regained weight after cessation of GBCA treatment. Conclusions: NSF-comparable pathological findings could not be induced by high dose intraperitoneal injection of seven GBCA.

  12. In an animal model nephrogenic systemic fibrosis cannot be induced by intraperitoneal injection of high-dose gadolinium based contrast agents

    International Nuclear Information System (INIS)

    Langer, R.D.; Lorke, D.E.; Neidl van Gorkom, K.F.; Petroianu, G.; Azimullah, S.; Nurulain, S.M.; Singh, S.; Fuchsjäger, M.

    2012-01-01

    Aim and objective: Nephrogenic systemic fibrosis (NSF) has been reported in humans to be most likely induced by gadolinium based contrast agents (GBCA), namely by gadodiamide, gadopentetate dimeglumine, and gadoversetamide, rarely by other GBCA. The pathogenesis of NSF remains unclear; different hypotheses are under discussion. The objective of the study is to assess if in the animal model human-like NSF changes can be induced by high-dose, intraperitoneal GBCA injections over four weeks. Materials and methods: After approval by the institutional animal ethics committee, six rats each were randomly assigned to groups, and treated with seven different GBCA. Intraperitoneal (IP) injections – proven in the animal model to be effective – were chosen to prolong the animals’ exposure to the respective GBCA. GBCA doses of previous intravenous (IV) animal studies were applied. After five weeks all rats were sacrificed. Sham controls were treated with IP saline injections, employing the same regimen. Results: No findings comparable with human NSF were observed in all animals after IP treatment with all seven GBCA at daily doses of 2.5 and 5.0 mmol/kg body weight (BW). No histopathological abnormalities of all examined organs were noted. Weight loss was stated in weeks three and four with GBCA injections at doses of 5.0 mmol/kg BW, but rats regained weight after cessation of GBCA treatment. Conclusions: NSF-comparable pathological findings could not be induced by high dose intraperitoneal injection of seven GBCA

  13. Contrast between hypervascularized liver lesions and hepatic parenchyma. Early dynamic PET versus contrast-enhanced CT

    International Nuclear Information System (INIS)

    Freesmeyer, M.; Winkens, T.; Schierz, J.-H.

    2014-01-01

    To detect hypervascularized liver lesions, early dynamic (ED) 18 F-FDG PET may be an alternative when contrast-enhanced (CE) imaging is infeasible. This retrospective pilot analysis compared contrast between such lesions and liver parenchyma, an important objective image quality variable, in ED PET versus CE CT. Twenty-eight hypervascularized liver lesions detected by CE CT [21 (75%) hepatocellular carcinomas; mean (range) diameter 4.9 ± 3.5 (1-14) cm] in 20 patients were scanned with ED PET. Using regions of interest, maximum and mean lesional and parenchymal signals at baseline, arterial and venous phases were calculated for ED PET and CE CT. Lesional/parenchymal signal ratio was significantly higher (P < 0.005) with ED PET versus CE CT at the arterial phase and similar between the methods at the venous phase. In liver imaging, ED PET generates greater lesional-parenchymal contrast during the arterial phase than does CE CT; these observations should be formally, prospectively evaluated. (author)

  14. Efficient quality-eactor estimation of a vertical cavity employing a high-contrast grating

    DEFF Research Database (Denmark)

    Taghizadeh, Alireza; Mørk, Jesper; Chung, Il-Sug

    2017-01-01

    Hybrid vertical cavity lasers employing high-contrast grating reflectors are attractive for Si-integrated light source applications. Here, a method for reducing a three-dimensional (3D) optical simulation of this laser structure to lower-dimensional simulations is suggested, which allows for very...... fast and approximate analysis of the quality-factor of the 3D cavity. This approach enables us to efficiently optimize the laser cavity design without performing cumbersome 3D simulations....

  15. High-contrast grating hollow-core waveguide splitter applied to optical phased array

    Science.gov (United States)

    Zhao, Che; Xue, Ping; Zhang, Hanxing; Chen, Te; Peng, Chao; Hu, Weiwei

    2014-11-01

    A novel hollow-core (HW) Y-branch waveguide splitter based on high-contrast grating (HCG) is presented. We calculated and designed the HCG-HW splitter using Rigorous Coupled Wave Analysis (RCWA). Finite-different timedomain (FDTD) simulation shows that the splitter has a broad bandwidth and the branching loss is as low as 0.23 dB. Fabrication is accomplished with standard Silicon-On-Insulator (SOI) process. The experimental measurement results indicate its good performance on beam splitting near the central wavelength λ = 1550 nm with a total insertion loss of 7.0 dB.

  16. Do intravenous N-acetylcysteine and sodium bicarbonate prevent high osmolal contrast-induced acute kidney injury? A randomized controlled trial.

    Directory of Open Access Journals (Sweden)

    Antonio Jose Inda-Filho

    Full Text Available N-acetylcysteine (NAC or sodium bicarbonate (NaHCO3, singly or combined, inconsistently prevent patients exposed to radiographic contrast media from developing contrast-induced acute kidney injury (CI-AKI.We asked whether intravenous isotonic saline and either NaHCO3 in 5% dextrose or else a high dose of NAC in 5% dextrose prevent CI-AKI in outpatients exposed to high-osmolal iodinated contrast medium more than does saline alone.This completed prospective, parallel, superiority, open-label, controlled, computer-randomized, single-center, Brazilian trial (NCT01612013 hydrated 500 adult outpatients (214 at high risk of developing CI-AKI exposed to ioxitalamate during elective coronary angiography and ventriculography. From 1 hour before through 6 hours after exposure, 126 patients (group 1 received a high dose of NAC and saline, 125 (group 2 received NaHCO3 and saline, 124 (group 3 received both treatments, and 125 (group 4 received only saline.Groups were similar with respect to age, gender, weight, pre-existing renal dysfunction, hypertension, medication, and baseline serum creatinine and serum cystatin C, but diabetes mellitus was significantly less prevalent in group 1. CI-AKI incidence 72 hours after exposure to contrast medium was 51.4% (257/500, measured as serum creatinine > (baseline+0.3 mg/dL and/or serum cystatin C > (1.1 · baseline, and 7.6% (38/500, measured as both serum creatinine and serum cystatin C > (baseline+0.3 mg/dL or > (1.25 · baseline. CI-AKI incidence measured less sensitively was similar among groups. Measured more sensitively, incidence in group 1 was significantly (p<0.05 lower than in groups 2 and 3 but not group 4; adjustment for confounding by infused volume equalized incidence in groups 1 and 3.We found no evidence that intravenous isotonic saline and either NaHCO3 or else a high dose of NAC prevent CI-AKI in outpatients exposed to high osmolal iodinated contrast medium more than does saline alone

  17. Iodinated contrast media nephrotoxicity

    International Nuclear Information System (INIS)

    Meyrier, A.

    1994-01-01

    In the late seventies, iodinated contrast agents (ICA) were considered to be a major cause of acute iatrogenic renal failure. Over the last decade new contrast agents have been synthesized, nonionic and less hyperosmolar. The incidence of acute renal failure due to ICAs, varies from 3.7 to 70% of cases according to the series, with an average figure of 10.2%. The pathophysiology of ICA nephrotoxicity was mainly studied in laboratory animal models. Three main factors are involved in an inducing ICA-mediated decrease in glomerular filtration rate: reduction of the renal plasma flow, a direct cytotoxic effect on renal tubular cells and erythrocyte alteration leading to intra-renal sludge. Excluding dysglobulinemias with urinary excretion of immunoglobulin light chains, which represent a special case of maximum nephrotoxicity, 4 main risk factors of renal toxicity have been identified in nondiabetic subjects: previous renal failure with serum creatinine levels greater than 140 μmol per liter, extracellular dehydration, age over 60 and use of high doses of ICA and/or repeated ICA injections before serum creatinine levels return to baseline. Preventive measures for avoiding ICA nephrotoxicity are threefold: maintain or restore adequate hydration with saline infusion, stop NSAID treatment several days before ICA administration, and allow a 5 day interval before repeating contrast media injections. New, nonionic and moderately hyperosmolar contrast agents appear to be much less nephrotoxic than conventional ICAs in laboratory animals and in high-risk patients. It is advisable to select such contrast media for investigating high-risk patients. This approach was recently substantiated in well designed, randomized clinical studies which included more than 2 000 patients. (author)

  18. In vivo x-ray phase contrast analyzer-based imaging for longitudinal osteoarthritis studies in guinea pigs

    Energy Technology Data Exchange (ETDEWEB)

    Coan, Paola [Faculty of Medicine and Institute of Clinical Radiology, Ludwig-Maximilians University, Munich (Germany); Wagner, Andreas; Mollenhauer, Juergen [Department of Orthopaedics of the University of Jena, Rudolf-Elle-Hospital Eisenberg (Germany); Bravin, Alberto; Diemoz, Paul C; Keyrilaeinen, Jani, E-mail: Paola.Coan@physik.uni-muenchen.d [European Synchrotron Radiation Facility (ESRF), Grenoble (France)

    2010-12-21

    Over the last two decades phase contrast x-ray imaging techniques have been extensively studied for applications in the biomedical field. Published results demonstrate the high capability of these imaging modalities of improving the image contrast of biological samples with respect to standard absorption-based radiography and routinely used clinical imaging techniques. A clear depiction of the anatomic structures and a more accurate disease diagnosis may be provided by using radiation doses comparable to or lower than those used in current clinical methods. In the literature many works show images of phantoms and excised biological samples proving the high sensitivity of the phase contrast imaging methods for in vitro investigations. In this scenario, the applications of the so-called analyzer-based x-ray imaging (ABI) phase contrast technique are particularly noteworthy. The objective of this work is to demonstrate the feasibility of in vivo x-ray ABI phase contrast imaging for biomedical applications and in particular with respect to joint anatomic depiction and osteoarthritis detection. ABI in planar and tomographic modes was performed in vivo on articular joints of guinea pigs in order to investigate the animals with respect to osteoarthritis by using highly monochromatic x-rays of 52 keV and a low noise detector with a pixel size of 47 x 47 {mu}m{sup 2}. Images give strong evidence of the ability of ABI in depicting both anatomic structures in complex systems as living organisms and all known signs of osteoarthritis with high contrast, high spatial resolution and with an acceptable radiation dose. This paper presents the first proof of principle study of in vivo application of ABI. The technical challenges encountered when imaging an animal in vivo are discussed. This experimental study is an important step toward the study of clinical applications of phase contrast x-ray imaging techniques.

  19. Transient analysis of electromagnetic wave interactions on high-contrast scatterers using volume electric field integral equation

    KAUST Repository

    Sayed, Sadeed Bin; Ulku, Huseyin Arda; Bagci, Hakan

    2014-01-01

    A marching on-in-time (MOT)-based time domain volume electric field integral equation (TD-VEFIE) solver is proposed for accurate and stable analysis of electromagnetic wave interactions on high-contrast scatterers. The stability is achieved using

  20. Elevated arousal levels enhance contrast perception.

    Science.gov (United States)

    Kim, Dongho; Lokey, Savannah; Ling, Sam

    2017-02-01

    Our state of arousal fluctuates from moment to moment-fluctuations that can have profound impacts on behavior. Arousal has been proposed to play a powerful, widespread role in the brain, influencing processes as far ranging as perception, memory, learning, and decision making. Although arousal clearly plays a critical role in modulating behavior, the mechanisms underlying this modulation remain poorly understood. To address this knowledge gap, we examined the modulatory role of arousal on one of the cornerstones of visual perception: contrast perception. Using a reward-driven paradigm to manipulate arousal state, we discovered that elevated arousal state substantially enhances visual sensitivity, incurring a multiplicative modulation of contrast response. Contrast defines vision, determining whether objects appear visible or invisible to us, and these results indicate that one of the consequences of decreased arousal state is an impaired ability to visually process our environment.

  1. Applications of energy loss contrast STIM

    International Nuclear Information System (INIS)

    Bench, G.; Saint, A.; Legge, G.J.F.; Cholewa, M.

    1992-01-01

    Scanning Transmission Ion Microscopy (STIM) with energy loss contrast is a quantitative imaging technique. A focussed MeV ion microbeam is scanned over the sample and measured energy losses of residual ions at each beam location are used to provide the contrast in the image. The technique is highly efficient as almost every ion carries useful information from which quantitative data can be obtained. The high efficiency of data collection at present necessitates the use of small beam currents. Therefore small apertures can be used and fine spatial resolution can be achieved. High efficiency also makes it possible to collect large data sets for high definition imaging with a small radiation dose. Owing to the simple relationship between energy loss and areal density, STIM with energy loss contrast can provide a quantitative image that can be used to obtain areal density information on the sample. These areal density maps can be used not only to provide a high resolution image of the sample but also to normalise Particle Induced Xray Emission (PIXE) data. The small radiation dose required to form these areal density maps also allows one to use STIM with energy loss contrast to quantitatively monitor ion beam induced specimen changes caused by higher doses and dose rates used in other microanalytical techniques. STIM with energy loss contrast also provides the possibility of stereo imaging and ion microtomography. STIM has also been used in conjunction with channeling to explore transmission channeling in thin crystals. This paper will discuss these applications of STIM with energy loss contrast and look at further developments from them

  2. Interaction of a high-order Bessel beam with a submerged spherical ultrasound contrast agent shell - Scattering theory.

    Science.gov (United States)

    Mitri, F G

    2010-03-01

    Acoustic scattering properties of ultrasound contrast agents are useful in extending existing or developing new techniques for biomedical imaging applications. A useful first step in this direction is to investigate the acoustic scattering of a new class of acoustic beams, known as helicoidal high-order Bessel beams, to improve the understanding of their scattering characteristics by an ultrasound contrast agent, which at present is very limited. The transverse acoustic scattering of a commercially available albuminoidal ultrasound contrast agent shell filled with air or a denser gas such as perfluoropropane and placed in a helicoidal Bessel beam of any order is examined numerically. The shell is assumed to possess an outer radius a=3.5 microns and a thickness of approximately 105 nm. Moduli of the total and resonance transverse acoustic scattering form functions are numerically evaluated in the bandwidth 0scattering of a helicoidal Bessel beam of order m1 so that the dynamics of contrast agents would be significantly altered. The main finding of the present theory is the suppression or enhancement for a particular resonance that may be used to advantage in imaging with ultrasound contrast agents for clinical applications. 2009 Elsevier B.V. All rights reserved.

  3. Polarized object detection in crabs: a two-channel system.

    Science.gov (United States)

    Basnak, Melanie Ailín; Pérez-Schuster, Verónica; Hermitte, Gabriela; Berón de Astrada, Martín

    2018-05-25

    Many animal species take advantage of polarization vision for vital tasks such as orientation, communication and contrast enhancement. Previous studies have suggested that decapod crustaceans use a two-channel polarization system for contrast enhancement. Here, we characterize the polarization contrast sensitivity in a grapsid crab . We estimated the polarization contrast sensitivity of the animals by quantifying both their escape response and changes in heart rate when presented with polarized motion stimuli. The motion stimulus consisted of an expanding disk with an 82 deg polarization difference between the object and the background. More than 90% of animals responded by freezing or trying to avoid the polarized stimulus. In addition, we co-rotated the electric vector (e-vector) orientation of the light from the object and background by increments of 30 deg and found that the animals' escape response varied periodically with a 90 deg period. Maximum escape responses were obtained for object and background e-vectors near the vertical and horizontal orientations. Changes in cardiac response showed parallel results but also a minimum response when e-vectors of object and background were shifted by 45 deg with respect to the maxima. These results are consistent with an orthogonal receptor arrangement for the detection of polarized light, in which two channels are aligned with the vertical and horizontal orientations. It has been hypothesized that animals with object-based polarization vision rely on a two-channel detection system analogous to that of color processing in dichromats. Our results, obtained by systematically varying the e-vectors of object and background, provide strong empirical support for this theoretical model of polarized object detection. © 2018. Published by The Company of Biologists Ltd.

  4. Direct imaging of phase objects enables conventional deconvolution in bright field light microscopy.

    Directory of Open Access Journals (Sweden)

    Carmen Noemí Hernández Candia

    Full Text Available In transmitted optical microscopy, absorption structure and phase structure of the specimen determine the three-dimensional intensity distribution of the image. The elementary impulse responses of the bright field microscope therefore consist of separate absorptive and phase components, precluding general application of linear, conventional deconvolution processing methods to improve image contrast and resolution. However, conventional deconvolution can be applied in the case of pure phase (or pure absorptive objects if the corresponding phase (or absorptive impulse responses of the microscope are known. In this work, we present direct measurements of the phase point- and line-spread functions of a high-aperture microscope operating in transmitted bright field. Polystyrene nanoparticles and microtubules (biological polymer filaments serve as the pure phase point and line objects, respectively, that are imaged with high contrast and low noise using standard microscopy plus digital image processing. Our experimental results agree with a proposed model for the response functions, and confirm previous theoretical predictions. Finally, we use the measured phase point-spread function to apply conventional deconvolution on the bright field images of living, unstained bacteria, resulting in improved definition of cell boundaries and sub-cellular features. These developments demonstrate practical application of standard restoration methods to improve imaging of phase objects such as cells in transmitted light microscopy.

  5. Magnetic iron oxide for contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Fahlvik, A.K.

    1991-05-01

    The main objective of this experimental work has been to study the biological fate and the contrast enhancing potential of a model preparation of magnetic iron oxide (MSM) after intravenous injection to rodents. This was achieved by: Studying in vitro contrast efficacy of various magnetic iron oxide preparations by relaxation analysis. Studying in vivo contrast efficacy of MSM by relaxation analysis and NMR imaging. Studying the biodistribution and bioelimination of MSM in independent experiments using relaxation analysis, radioactivity studies and histological techniques. Studying interactions of MSM with target cells and target organelles using ex vivo techniques. Based on the presented experimental study, the MSM model preparation of magnetic iron oxide seems to fulfill basic requirements of NMR contrast agents: efficient proton relaxation, specific in vivo distribution, and biological tolerance. 177 refs., 5 figs., 2 tabs

  6. Effect of atorvastatin on preventing contrast-induced nephropathy

    International Nuclear Information System (INIS)

    Zhang Dongya; Zhu Jing; Chen Jianchang; Xu Weiting; Luo Xiaoyu; Zhao Liangping

    2011-01-01

    Objective: To study the effects of atorvastatin on contrast-induced renal function and urinary protein change in patients undergoing diagnostic and therapeutic coronary intervention. Methods: Two hundred and forty-six patients who underwent coronary angiography or percutaneous coronary intervention (PCI) were randomized to receive atorvastatin (40 mg, qn, n=123) or no atorvastatin (n=123) treatment 3 days before coronary angiography. All patients received hydrated therapy. Serum creatinine (Scr), urinary αl-microglobulin (α l -MG), and urinary albumin (mALB) were checked for evidence of tubular or glomerular damage at start, and 36 to 48 hours after the administration of a radiocontrast agent. High-sensitive C-reactive protein (hsCRP) levels, urinary α l -MG/ urinary creatinine(Ucr) and mALB/ Ucr were also assessed at the same time. Creatinine clearance(Ccr) was calculated according to Cockcroft-Gault formulas basing on serum creatinine. Results: (1) In the control group and atorvastatin-treated group, comparison with the value before coronary angiography or PCI, urinary α l -MG/ Ucr, mALB/ Ucr, Scr and hsCRP significantly increased from 36 to 48 hours after angiography or PCI (P l -MG/ Ucr significantly increased at the 2nd day after angiography or PCI in the control group (P<0.05), incidence of contrast induced nephropathy (CIN) significantly increased too (8.13% vs 0.81%, P<0.05). Conclusions: Contrast media induces light renal function damage. Pretreatment with atorvastatin 40 mg/qn for 3 days could significantly reduce procedural inflammatory reaction and prevent contrast-induced nephropathy. (authors)

  7. Experiencing More Mathematics Anxiety than Expected? Contrasting Trait and State Anxiety in High Achieving Students

    Science.gov (United States)

    Roos, A.-L.; Bieg, M.; Goetz, T.; Frenzel, A. C.; Taxer, J.; Zeidner, M.

    2015-01-01

    This study examined mathematics anxiety among high and low achieving students (N = 237, grades 9 and 10) by contrasting trait (habitual) and state (momentary) assessments of anxiety. Previous studies have found that trait anxiety measures are typically rated higher than state measures. Furthermore, the academic self-concept has been identified to…

  8. The Value of Contrast Echocardiography

    Directory of Open Access Journals (Sweden)

    Shannon C. Treiber

    2016-01-01

    Full Text Available Purpose: There is much evidence-based research proving the effectiveness of contrast echocardiography, but there are still questions and concerns about its specific uses. This study tested the effectiveness of contrast echocardiography in defining the left ventricular endocardial border. Methods: From 30 patients, a total of 60 echocardiograms –– 30 with and 30 without use of contrast –– were retrospectively reviewed by four blinded cardiologists with advanced training in echocardiography. No single cardiologist reviewed contrast and noncontrast images of the same patient. Each set of 30 echocardiograms was then studied for wall-motion scoring. Visualization of left ventricular wall segments and a global visualization confidence level of interpretation were recorded. Results: Of all wall segments (N = 510, 91% were visualized in echocardiograms with use of contrast, whereas 75% of the walls were visualized in echocardiograms without contrast (P < 0.001. Of 30 examinations, 17 contrast echocardiograms were read with high confidence compared to 6 without contrast use (P = 0.004. The number of walls visualized with contrast was increased in 18 patients (60%, whereas noncontrast echocardiograms yielded more visualized walls in 6 patients (20%, P = 0.002. Conclusions: This study demonstrates that contrast is valuable to echocardiographic imaging. Its use should be supported throughout echocardiography clinics and encouraged in certain patients for whom resting and stress echocardiography results without contrast often prove uninterpretable.

  9. A cross-stacked plasmonic nanowire network for high-contrast femtosecond optical switching.

    Science.gov (United States)

    Lin, Yuanhai; Zhang, Xinping; Fang, Xiaohui; Liang, Shuyan

    2016-01-21

    We report an ultrafast optical switching device constructed by stacking two layers of gold nanowires into a perpendicularly crossed network, which works at a speed faster than 280 fs with an on/off modulation depth of about 22.4%. The two stacks play different roles in enhancing consistently the optical switching performance due to their different dependence on the polarization of optical electric fields. The cross-plasmon resonance based on the interaction between the perpendicularly stacked gold nanowires and its Fano-coupling with Rayleigh anomaly is the dominant mechanism for such a high-contrast optical switching device.

  10. Evaluation of the acute adverse reaction of contrast medium with high and moderate iodine concentration in patients undergoing computed tomography

    International Nuclear Information System (INIS)

    Nagamoto, Masashi; Gomi, Tatsuya; Terada, Hitoshi; Terada, Shigehiko; Kohda, Eiichi

    2006-01-01

    The aim of this prospective study was to evaluate and compare acute adverse reactions between contrast medium containing moderate and high concentrations of iodine in patients undergoing computed tomography (CT). A total of 945 patients undergoing enhanced CT were randomly assigned to receive one of two doses of contrast medium. We then prospectively investigated the incidence of adverse reactions. Iopamidol was used as the contrast medium, with a high concentration of 370 mgI/ml and a moderate concentration of 300 mgI/ml. The frequency of adverse reactions, such as pain at the injection site and heat sensation, were determined. Acute adverse reactions were observed in 2.4% (11/458) of the moderate-concentration group compared to 3.11% (15/482) of the high-concentration group; there was no significant difference in incidence between the two groups. Most adverse reactions were mild, and there was no significant difference in severity. One patient in the high-concentration group was seen to have a moderate adverse reaction. No correlation existed between the incidence of adverse reactions and patient characteristics such as sex, age, weight, flow amount, and flow rate. The incidence of pain was not significantly different between the two groups. In contrast, the incidence of heat sensation was significantly higher in the high-concentration group. The incidence and severity of acute adverse reactions were not significantly different between the two groups, and there were no severe adverse reactions in either group. (author)

  11. Contrast-enhanced peripheral MRA

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-01-01

    MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic......-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged...... intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal...

  12. Dual-energy contrast-enhanced spectral mammography (CESM).

    Science.gov (United States)

    Daniaux, Martin; De Zordo, Tobias; Santner, Wolfram; Amort, Birgit; Koppelstätter, Florian; Jaschke, Werner; Dromain, Clarisse; Oberaigner, Willi; Hubalek, Michael; Marth, Christian

    2015-10-01

    Dual-energy contrast-enhanced mammography is one of the latest developments in breast care. Imaging with contrast agents in breast cancer was already known from previous magnetic resonance imaging and computed tomography studies. However, high costs, limited availability-or high radiation dose-led to the development of contrast-enhanced spectral mammography (CESM). We reviewed the current literature, present our experience, discuss the advantages and drawbacks of CESM and look at the future of this innovative technique.

  13. Moderate contrast in the evaluation of paintings is liked more but remembered less than high contrast

    NARCIS (Netherlands)

    K. Dijkstra (Katinka); van Dongen, N.N.N. (Noah N.N.)

    2017-01-01

    textabstractMany visual aspects of paintings, as well as exposure to art and cultural norms, contribute to the aesthetic evaluation of paintings. The current study looked at heightened visual contrast as an important factor in the appreciation of paintings. Participants evaluated abstract digitized

  14. Enhancement tuning and control for high dynamic range images in multi-scale locally adaptive contrast enhancement algorithms

    Science.gov (United States)

    Cvetkovic, Sascha D.; Schirris, Johan; de With, Peter H. N.

    2009-01-01

    For real-time imaging in surveillance applications, visibility of details is of primary importance to ensure customer confidence. If we display High Dynamic-Range (HDR) scenes whose contrast spans four or more orders of magnitude on a conventional monitor without additional processing, results are unacceptable. Compression of the dynamic range is therefore a compulsory part of any high-end video processing chain because standard monitors are inherently Low- Dynamic Range (LDR) devices with maximally two orders of display dynamic range. In real-time camera processing, many complex scenes are improved with local contrast enhancements, bringing details to the best possible visibility. In this paper, we show how a multi-scale high-frequency enhancement scheme, in which gain is a non-linear function of the detail energy, can be used for the dynamic range compression of HDR real-time video camera signals. We also show the connection of our enhancement scheme to the processing way of the Human Visual System (HVS). Our algorithm simultaneously controls perceived sharpness, ringing ("halo") artifacts (contrast) and noise, resulting in a good balance between visibility of details and non-disturbance of artifacts. The overall quality enhancement, suitable for both HDR and LDR scenes, is based on a careful selection of the filter types for the multi-band decomposition and a detailed analysis of the signal per frequency band.

  15. High performance distributed objects in large hadron collider experiments

    International Nuclear Information System (INIS)

    Gutleber, J.

    1999-11-01

    This dissertation demonstrates how object-oriented technology can support the development of software that has to meet the requirements of high performance distributed data acquisition systems. The environment for this work is a system under planning for the Compact Muon Solenoid experiment at CERN that shall start its operation in the year 2005. The long operational phase of the experiment together with a tight and puzzling interaction with custom devices make the quest for an evolvable architecture that exhibits a high level of abstraction the driving issue. The question arises if an existing approach already fits our needs. The presented work casts light on these problems and as a result comprises the following novel contributions: - Application of object technology at hardware/software boundary. Software components at this level must be characterised by high efficiency and extensibility at the same time. - Identification of limitations when deploying commercial-off-the-shelf middleware for distributed object-oriented computing. - Capturing of software component properties in an efficiency model for ease of comparison and improvement. - Proof of feasibility that the encountered deficiencies in middleware can be avoided and that with the use of software components the imposed requirements can be met. - Design and implementation of an on-line software control system that allows to take into account the ever evolving requirements by avoiding hardwired policies. We conclude that state-of-the-art middleware cannot meet the required efficiency of the planned data acquisition system. Although new tool generations already provide a certain degree of configurability, the obligation to follow standards specifications does not allow the necessary optimisations. We identified the major limiting factors and argue that a custom solution following a component model with narrow interfaces can satisfy our requirements. This approach has been adopted for the current design

  16. Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm

    International Nuclear Information System (INIS)

    Ahmadian, Alireza; Ay, Mohammad R.; Sarkar, Saeed; Bidgoli, Javad H.; Zaidi, Habib

    2008-01-01

    Oral contrast is usually administered in most X-ray computed tomography (CT) examinations of the abdomen and the pelvis as it allows more accurate identification of the bowel and facilitates the interpretation of abdominal and pelvic CT studies. However, the misclassification of contrast medium with high-density bone in CT-based attenuation correction (CTAC) is known to generate artifacts in the attenuation map (μmap), thus resulting in overcorrection for attenuation of positron emission tomography (PET) images. In this study, we developed an automated algorithm for segmentation and classification of regions containing oral contrast medium to correct for artifacts in CT-attenuation-corrected PET images using the segmented contrast correction (SCC) algorithm. The proposed algorithm consists of two steps: first, high CT number object segmentation using combined region- and boundary-based segmentation and second, object classification to bone and contrast agent using a knowledge-based nonlinear fuzzy classifier. Thereafter, the CT numbers of pixels belonging to the region classified as contrast medium are substituted with their equivalent effective bone CT numbers using the SCC algorithm. The generated CT images are then down-sampled followed by Gaussian smoothing to match the resolution of PET images. A piecewise calibration curve was then used to convert CT pixel values to linear attenuation coefficients at 511 keV. The visual assessment of segmented regions performed by an experienced radiologist confirmed the accuracy of the segmentation and classification algorithms for delineation of contrast-enhanced regions in clinical CT images. The quantitative analysis of generated μmaps of 21 clinical CT colonoscopy datasets showed an overestimation ranging between 24.4% and 37.3% in the 3D-classified regions depending on their volume and the concentration of contrast medium. Two PET/CT studies known to be problematic demonstrated the applicability of the technique in

  17. Contrast detail phantom for SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Cabrejas, M.L. de; Arashiro, J G; Giannone, C. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Camuyrano, M; Nohara, G [Universidad de Buenos Aires, Buenos Aires (Argentina). Facultad Ciencias Exactas

    1996-06-01

    A new low variable contrast phantom for single photon emission computed tomography (SPECT) was constructed, tested and compared with other existing phantoms. It contains simulated cylindrical lesions of four different diameters (D{sub i}), embedded in a cylindrical scattering medium and a uniform section to evaluate tomographic uniformity. The concentration of tracer in the simulated lesions and the scattering medium (background) can be varied to simulate hot and cold lesions. Different applications of the phantom were tested, including determination of the minimum object contrast (OCm) necessary to detect lesions as a function of lesion size, lesion type (hot or cold) and acquisition and processing protocols by visual inspection. This parameter allows categorization of instruments comparing an `image quality index` (IQI). Preliminary comparison with the Britten contrast processing method showed that the detectable OCm was of the same order of magnitude, but the presented device seems more suitable for training and intercomparison purposes. The constructed phantom, of simple design, has proved to be useful for acquisition and processing condition evaluation, OCm estimation and external quality control. (author). 11 refs, 4 figs.

  18. Ultrashort Echo Time Magnetic Resonance Imaging of the Lung Using a High-Relaxivity T1 Blood-Pool Contrast Agent

    Directory of Open Access Journals (Sweden)

    Joris Tchouala Nofiele

    2014-10-01

    Full Text Available The lung remains one of the most challenging organs to image using magnetic resonance imaging (MRI due to intrinsic rapid signal decay. However, unlike conventional modalities such as computed tomography, MRI does not involve radiation and can provide functional and morphologic information on a regional basis. Here we demonstrate proof of concept for a new MRI approach to achieve substantial gains in a signal to noise ratio (SNR in the lung parenchyma: contrast-enhanced ultrashort echo time (UTE imaging following intravenous injection of a high-relaxivity blood-pool manganese porphyrin T1 contrast agent. The new contrast agent increased relative enhancement of the lung parenchyma by over 10-fold compared to gadolinium diethylene triamine pentaacetic acid (Gd-DTPA, and the use of UTE boosted the SNR by a factor of 4 over conventional T1-weighted gradient echo acquisitions. The new agent also maintains steady enhancement over at least 60 minutes, thus providing a long time window for obtaining high-resolution, high-quality images and the ability to measure a number of physiologic parameters.

  19. Interqubit coupling mediated by a high-excitation-energy quantum object

    NARCIS (Netherlands)

    Ashhab, S.; Niskanen, A.O.; Harrabi, K.; Nakamura, Y.; Picot, T.; De Groot, P.C.; Harmans, C.J.P.M.; Mooij, J.E.; Nori, F.

    2008-01-01

    We consider a system composed of two qubits and a high excitation energy quantum object used to mediate coupling between the qubits. We treat the entire system quantum mechanically and analyze the properties of the eigenvalues and eigenstates of the total Hamiltonian. After reproducing well known

  20. Application of iodic contrast media in roentgen examinations

    International Nuclear Information System (INIS)

    Mielecki, T.; Januszkiewicz-Mielecka, K.; Kukula, A.; Szechinski, J.

    1993-01-01

    An analysis of adverse reactions after administration of iodic contrast media in 1780 patients in 1952 various X-ray examinations is presented. Various preparations by different producers were used. As a rule, domestic contrast media were administered in non high-risk patients, whereas imported contrast media were applied in patients with documented high-risk factors (20%) and nonionic compounds were intended for patients of severe clinical condition (10%). Adverse reactions occurred in 6.9% of non high-risk patients and in 10.9% of high-risk patients. Nonionic preparations caused adverse reactions in 5.6%. Considering the significant differences in prices of domestic, imported and nonionic contrast media, authors advice to use safer but clearly more expensive preparations in patients with documented factors of increased risk. (author)

  1. Concept of contrast transfer function for edge illumination x-ray phase-contrast imaging and its comparison with the free-space propagation technique.

    Science.gov (United States)

    Diemoz, Paul C; Vittoria, Fabio A; Olivo, Alessandro

    2016-05-16

    Previous studies on edge illumination (EI) X-ray phase-contrast imaging (XPCi) have investigated the nature and amplitude of the signal provided by this technique. However, the response of the imaging system to different object spatial frequencies was never explicitly considered and studied. This is required in order to predict the performance of a given EI setup for different classes of objects. To this scope, in the present work we derive analytical expressions for the contrast transfer function of an EI imaging system, using the approximation of near-field regime, and study its dependence upon the main experimental parameters. We then exploit these results to compare the frequency response of an EI system with respect of that of a free-space propagation XPCi one. The results achieved in this work can be useful for predicting the signals obtainable for different types of objects and also as a basis for new retrieval methods.

  2. Local contrast-enhanced MR images via high dynamic range processing.

    Science.gov (United States)

    Chandra, Shekhar S; Engstrom, Craig; Fripp, Jurgen; Neubert, Ales; Jin, Jin; Walker, Duncan; Salvado, Olivier; Ho, Charles; Crozier, Stuart

    2018-09-01

    To develop a local contrast-enhancing and feature-preserving high dynamic range (HDR) image processing algorithm for multichannel and multisequence MR images of multiple body regions and tissues, and to evaluate its performance for structure visualization, bias field (correction) mitigation, and automated tissue segmentation. A multiscale-shape and detail-enhancement HDR-MRI algorithm is applied to data sets of multichannel and multisequence MR images of the brain, knee, breast, and hip. In multisequence 3T hip images, agreement between automatic cartilage segmentations and corresponding synthesized HDR-MRI series were computed for mean voxel overlap established from manual segmentations for a series of cases. Qualitative comparisons between the developed HDR-MRI and standard synthesis methods were performed on multichannel 7T brain and knee data, and multisequence 3T breast and knee data. The synthesized HDR-MRI series provided excellent enhancement of fine-scale structure from multiple scales and contrasts, while substantially reducing bias field effects in 7T brain gradient echo, T 1 and T 2 breast images and 7T knee multichannel images. Evaluation of the HDR-MRI approach on 3T hip multisequence images showed superior outcomes for automatic cartilage segmentations with respect to manual segmentation, particularly around regions with hyperintense synovial fluid, across a set of 3D sequences. The successful combination of multichannel/sequence MR images into a single-fused HDR-MR image format provided consolidated visualization of tissues within 1 omnibus image, enhanced definition of thin, complex anatomical structures in the presence of variable or hyperintense signals, and improved tissue (cartilage) segmentation outcomes. © 2018 International Society for Magnetic Resonance in Medicine.

  3. Peripheral Vasculature: High-Temporal- and High-Spatial-Resolution Three-dimensional Contrast-enhanced MR Angiography1

    Science.gov (United States)

    Haider, Clifton R.; Glockner, James F.; Stanson, Anthony W.; Riederer, Stephen J.

    2009-01-01

    Purpose: To prospectively evaluate the feasibility of performing high-spatial-resolution (1-mm isotropic) time-resolved three-dimensional (3D) contrast material–enhanced magnetic resonance (MR) angiography of the peripheral vasculature with Cartesian acquisition with projection-reconstruction–like sampling (CAPR) and eightfold accelerated two-dimensional (2D) sensitivity encoding (SENSE). Materials and Methods: All studies were approved by the institutional review board and were HIPAA compliant; written informed consent was obtained from all participants. There were 13 volunteers (mean age, 41.9; range, 27–53 years). The CAPR sequence was adapted to provide 1-mm isotropic spatial resolution and a 5-second frame time. Use of different receiver coil element sizes for those placed on the anterior-to-posterior versus left-to-right sides of the field of view reduced signal-to-noise ratio loss due to acceleration. Results from eight volunteers were rated independently by two radiologists according to prominence of artifact, arterial to venous separation, vessel sharpness, continuity of arterial signal intensity in major arteries (anterior and posterior tibial, peroneal), demarcation of origin of major arteries, and overall diagnostic image quality. MR angiographic results in two patients with peripheral vascular disease were compared with their results at computed tomographic angiography. Results: The sequence exhibited no image artifact adversely affecting diagnostic image quality. Temporal resolution was evaluated to be sufficient in all cases, even with known rapid arterial to venous transit. The vessels were graded to have excellent sharpness, continuity, and demarcation of the origins of the major arteries. Distal muscular branches and the communicating and perforating arteries were routinely seen. Excellent diagnostic quality rating was given for 15 (94%) of 16 evaluations. Conclusion: The feasibility of performing high-diagnostic-quality time-resolved 3D

  4. Contrast enhanced MRA: do contrast agents with a higher T1 relaxitivity improve the visualization of carotid artery stenoses?

    International Nuclear Information System (INIS)

    Friese, S.; Krapf, H.; Skalej, M.; Kueker, W.; Fetter, M.; Vonthein, R.

    2001-01-01

    CE-MRA is a powerful tool for the non-invasive evaluation of carotid artery occlusive disease. However, due to certain drawbacks, it has not completely replaced DSA. The purpose of this study was to evaluate if Gd-BOPTA, a contrast agent with high T 1 relaxivity, can increase the diagnostic accuracy of CE-MRA. Material and Methods: The CE-MRA examinations of 54 consecutive patients were evaluated by two experienced radiologists, independently. The examinations of 27 patients were contrasted either with 20 ml Gd-BOPTA or with 20 ml Gd-DTPA. The reviewers were blinded to the contrast agent chosen and to the ultrasound results. They rated the overall image quality and the degree of the ICA stenoses. Results: For the estimation of the degree of the ICA stenoses there was a high interrater validity. In comparison to the ultrasound findings, 6 of 50 high-degree stenoses were underestimated as moderate stenoses. In one of seven sonographically occluded vessels, MRA revealed residual patency in the vessel lumen. It was not possible to identify the contrast agent that was taken for a study. Subjective estimation of the image quality (arterial contrast of the ICA, contrast of the other vessels, and general impression) did not significantly change with the contrast agent employed. Conclusion: The diagnostic accuracy of CE-MRA for the evaluation of internal carotid artery stenoses is not improved by Gd-BOPTA if identical volumina of contrast media are applied. The potential of this contrast agent can be the reduction of the amount of contrast without loss of diagnostic information. Further studies are necessary. (orig.) [de

  5. The influence of body temperature on image contrast in post mortem MRI

    International Nuclear Information System (INIS)

    Ruder, Thomas D.; Hatch, Gary M.; Siegenthaler, Lea; Ampanozi, Garyfalia; Mathier, Sandra; Thali, Michael J.; Weber, Oliver M.

    2012-01-01

    Objective: To assess the temperature dependency of tissue contrast on post mortem magnetic resonance (PMMR) images both objectively and subjectively; and to visually demonstrate the changes of image contrast at various temperatures. Materials and methods: The study was approved by the responsible justice department and the ethics committee. The contrast of water, fat, and muscle was measured using regions of interest (ROI) in the orbit of 41 human corpses to assess how body temperature (range 2.1–39.8 °C) relates to image contrast of T1-weighted (T1W) and T2-weighted (T2W) sequences on PMMR. Regressions were calculated using the method of least squares. Three readers judged visible changes of image contrast subjectively by consensus. Results: There was a positive relationship between temperature and contrast on T1-weighted (T1W) images and between temperature and the contrast of fat/muscle on T2-weighted (T2W) images. There was a negative relationship between temperature and the contrast of water/fat and water/muscle on T2W images. Subjectively, the influence of temperature became visible below 20 °C on T2W images, and below 10 °C on T1W images. Conclusion: Image contrast on PMMR depends on the temperature of a corpse. Radiologists involved in post mortem imaging must be aware of temperature-related changes in MR image contrast. To preserve technical quality, scanning corpses below 10 °C should be avoided.

  6. Tracer kinetic model selection for dynamic contrast-enhanced magnetic resonance imaging of locally advanced cervical cancer

    DEFF Research Database (Denmark)

    Kallehauge, Jesper Folsted; Tanderup, Kari; Duan, Chong

    2014-01-01

    , the TM was optimal in 17.0%, the ETM was optimal in 2.2%, the C-TU in 23.4% and the 2CXM was optimal in 57.3%. Throughout the tumour, a high correlation was found between Ktrans(TM) and Fp(2CXM), ρ = 0.91. Conclusion. The 2CXM was most often optimal in describing the contrast agent enhancement of pre......Background. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) offers a unique capability to probe tumour microvasculature. Different analysis of the acquired data will possibly lead to different conclusions. Therefore, the objective of this study was to investigate under which...

  7. Scaling Limit of Symmetric Random Walk in High-Contrast Periodic Environment

    Science.gov (United States)

    Piatnitski, A.; Zhizhina, E.

    2017-11-01

    The paper deals with the asymptotic properties of a symmetric random walk in a high contrast periodic medium in Z^d, d≥1. From the existing homogenization results it follows that under diffusive scaling the limit behaviour of this random walk need not be Markovian. The goal of this work is to show that if in addition to the coordinate of the random walk in Z^d we introduce an extra variable that characterizes the position of the random walk inside the period then the limit dynamics of this two-component process is Markov. We describe the limit process and observe that the components of the limit process are coupled. We also prove the convergence in the path space for the said random walk.

  8. THE INDIRECT OBJECT (IO) – ALBANIAN AND ENGLISH

    OpenAIRE

    Shkelqim Millaku; Xhevahire Topanica

    2016-01-01

    The aim of this study is too corporate the function of the indirect object between Albanian and English language. The function and the Albanian typical case for indirect object are dative and ablative. This grammatical phenomena is the full contrast between two languages because in English language doesn’t exist dative and ablative us in Albanian. In Albanian and English language, the indirect object is more heterogenic than the direct object. The indirect (direct) object in both of languages...

  9. Low Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    Science.gov (United States)

    2017-10-01

    greater gas polarizations and production amounts/ throughputs- benefiting in particular from the advent of com- pact, high-power, relatively low- cost ...Award Number: W81XWH-15-1-0271 TITLE: Low- Cost , High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI...DISTRIBUTION STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the

  10. Evaluation of the therapeutic efficacy of high-intensity focused ultrasound ablation of hepatocellular carcinoma by three-dimensional sonography with a perflubutane-based contrast agent

    International Nuclear Information System (INIS)

    Numata, Kazushi; Fukuda, Hiroyuki; Ohto, Masao; Itou, Ryu; Nozaki, Akito; Kondou, Masaaki; Morimoto, Manabu; Karasawa, Eii; Tanaka, Katsuaki

    2010-01-01

    Objective: We performed contrast-enhanced three-dimensional sonography (CE 3D US) with a perflubutane-based contrast agent to immediately evaluate the completeness of ablation of small hepatocellular carcinoma (HCC) lesions by extracorporeal high-intensity focused ultrasound (HIFU). Subjects and methods: Twenty-one HCC lesions were treated by a single ultrasound-guided HIFU ablation session, and CE 3D US was performed before, immediately after, and 1 week, and 1 month after HIFU, and contrast-enhanced CT (CE CT) or contrast-enhanced MRI (CE MRI) was performed before HIFU, 1 week and 1 month after HIFU, and during the follow-up period. Results: Immediately and 1 month after HIFU, 17 lesions were evaluated as adequately ablated by CE 3D US, and the other 4 lesions as residual tumors. One month after HIFU, 18 were evaluated as adequately ablated by CE CT or CE MRI, and the other 3 as residual tumors. The evaluation by CE 3D US immediately after HIFU and by CE CT or CE MRI 1 month after HIFU was concordant with 20 lesions. The kappa value for agreement between the findings of CE 3D US and other modalities by two blinded observers was 0.83. When the 1-month CE CT or CE MRI findings were used as the reference standard, the sensitivity, specificity, and accuracy of CE 3D US immediately after HIFU for the diagnosis of the adequate ablation were 100%, 75%, and 95%, respectively. Conclusion: CE 3D US appears to be a useful method for immediate evaluation of therapeutic efficacy of HIFU ablation of HCC lesions.

  11. Evaluation of the therapeutic efficacy of high-intensity focused ultrasound ablation of hepatocellular carcinoma by three-dimensional sonography with a perflubutane-based contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Numata, Kazushi, E-mail: kz-numa@urahp.yokohama-cu.ac.j [Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa 232-0024 (Japan); Fukuda, Hiroyuki; Ohto, Masao; Itou, Ryu [Department of Internal Medicine, Naruto General Hospital, 167 Naruto, Sanbu, Chiba 289-1326 (Japan); Nozaki, Akito; Kondou, Masaaki; Morimoto, Manabu [Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa 232-0024 (Japan); Karasawa, Eii [Department of Gastroenterology, International University of Health and Welfare Atami Hospital, 13-1 Higashi Kaigan-cho, Atami, Shizuoka 413-0012 (Japan); Tanaka, Katsuaki [Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa 232-0024 (Japan)

    2010-08-15

    Objective: We performed contrast-enhanced three-dimensional sonography (CE 3D US) with a perflubutane-based contrast agent to immediately evaluate the completeness of ablation of small hepatocellular carcinoma (HCC) lesions by extracorporeal high-intensity focused ultrasound (HIFU). Subjects and methods: Twenty-one HCC lesions were treated by a single ultrasound-guided HIFU ablation session, and CE 3D US was performed before, immediately after, and 1 week, and 1 month after HIFU, and contrast-enhanced CT (CE CT) or contrast-enhanced MRI (CE MRI) was performed before HIFU, 1 week and 1 month after HIFU, and during the follow-up period. Results: Immediately and 1 month after HIFU, 17 lesions were evaluated as adequately ablated by CE 3D US, and the other 4 lesions as residual tumors. One month after HIFU, 18 were evaluated as adequately ablated by CE CT or CE MRI, and the other 3 as residual tumors. The evaluation by CE 3D US immediately after HIFU and by CE CT or CE MRI 1 month after HIFU was concordant with 20 lesions. The kappa value for agreement between the findings of CE 3D US and other modalities by two blinded observers was 0.83. When the 1-month CE CT or CE MRI findings were used as the reference standard, the sensitivity, specificity, and accuracy of CE 3D US immediately after HIFU for the diagnosis of the adequate ablation were 100%, 75%, and 95%, respectively. Conclusion: CE 3D US appears to be a useful method for immediate evaluation of therapeutic efficacy of HIFU ablation of HCC lesions.

  12. Gap-enhanced Raman tags for high-contrast sentinel lymph node imaging.

    Science.gov (United States)

    Bao, Zhouzhou; Zhang, Yuqing; Tan, Ziyang; Yin, Xia; Di, Wen; Ye, Jian

    2018-05-01

    The sentinel lymph node (SLN) biopsy is gaining in popularity as a procedure to investigate the lymphatic metastasis of malignant tumors. The commonly used techniques to identify the SLNs in clinical practice are blue dyes-guided visualization, radioisotope-based detection and near-infrared fluorescence imaging. However, all these methods have not been found to perfectly fit the clinical criteria with issues such as short retention time in SLN, poor spatial resolution, autofluorescence, low photostability and high cost. In this study, we have reported a new type of nanoprobes, named, gap-enhanced Raman tags (GERTs) for the SLN Raman imaging. With the advantageous features including unique "fingerprint" Raman signal, strong Raman enhancement, high photostability, good biocompatibility and extra-long retention time, we have demonstrated that GERTs are greatly favorable for high-contrast and deep SLN Raman imaging, which meanwhile reveals the dynamic migration behavior of the probes entering the SLN. In addition, a quantitative volumetric Raman imaging (qVRI) data-processing method is employed to acquire a high-resolution 3-dimensional (3D) margin of SLN as well as the content variation of GERTs in the SLN. Moreover, SLN detection could be realized via a cost-effective commercial portable Raman scanner. Therefore, GERTs hold the great potential to be translated in clinical application for accurate and intraoperative location of the SLN. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Benchtop phase-contrast X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gundogdu, O. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)], E-mail: o.gundogdu@surrey.ac.uk; Nirgianaki, E.; Che Ismail, E.; Jenneson, P.M.; Bradley, D.A. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2007-12-15

    Clinical radiography has traditionally been based on contrast obtained from absorption when X-rays pass through the body. The contrast obtained from traditional radiography can be rather poor, particularly when it comes to soft tissue. A wide range of media of interest in materials science, biology and medicine exhibit very weak absorption contrast, but they nevertheless produce significant phase shifts with X-rays. The use of phase information for imaging purposes is therefore an attractive prospect. Some of the X-ray phase-contrast imaging methods require highly monochromatic plane wave radiation and sophisticated X-ray optics. However, the propagation-based phase-contrast imaging method adapted in this paper is a relatively simple method to implement, essentially requiring only a microfocal X-ray tube and electronic detection. In this paper, we present imaging results obtained from two different benchtop X-ray sources employing the free space propagation method. X-ray phase-contrast imaging provides higher contrast in many samples, including biological tissues that have negligible absorption contrast.

  14. Detection of admittivity anomaly on high-contrast heterogeneous backgrounds using frequency difference EIT.

    Science.gov (United States)

    Jang, J; Seo, J K

    2015-06-01

    This paper describes a multiple background subtraction method in frequency difference electrical impedance tomography (fdEIT) to detect an admittivity anomaly from a high-contrast background conductivity distribution. The proposed method expands the use of the conventional weighted frequency difference EIT method, which has been used limitedly to detect admittivity anomalies in a roughly homogeneous background. The proposed method can be viewed as multiple weighted difference imaging in fdEIT. Although the spatial resolutions of the output images by fdEIT are very low due to the inherent ill-posedness, numerical simulations and phantom experiments of the proposed method demonstrate its feasibility to detect anomalies. It has potential application in stroke detection in a head model, which is highly heterogeneous due to the skull.

  15. Interactive effects of size, contrast, intensity and configuration of background objects in evoking disruptive camouflage in cuttlefish.

    Science.gov (United States)

    Chiao, Chuan-Chin; Chubb, Charles; Hanlon, Roger T

    2007-07-01

    Disruptive body coloration is a primary camouflage tactic of cuttlefish. Because rapid changeable coloration of cephalopods is guided visually, we can present different visual backgrounds (e.g., computer-generated, two-dimensional prints) and video record the animal's response by describing and grading its body pattern. We showed previously that strength of cuttlefish disruptive patterning depends on the size, contrast, and density of discrete light elements on a homogeneous dark background. Here we report five experiments on the interactions of these and other features. Results show that Weber contrast of light background elements is--in combination with element size--a powerful determinant of disruptive response strength. Furthermore, the strength of disruptive patterning decreases with increasing mean substrate intensity (with other factors held constant). Interestingly, when element size, Weber contrast and mean substrate intensity are kept constant, strength of disruptive patterning depends on the configuration of clusters of small light elements. This study highlights the interactions of multiple features of natural microhabitats that directly influence which camouflage pattern a cuttlefish will choose.

  16. Optimization and stability of the contrast transfer function in aberration-corrected electron microscopy

    International Nuclear Information System (INIS)

    Tromp, R.M.; Schramm, S.M.

    2013-01-01

    The Contrast Transfer Function (CTF) describes the manner in which the electron microscope modifies the object exit wave function as a result of objective lens aberrations. For optimum resolution in C 3 -corrected microscopes it is well established that a small negative value of C 3 , offset by positive values of C 5 and defocus C 1 results in the most optimal instrument resolution, and optimization of the CTF has been the subject of several studies. Here we describe a simple design procedure for the CTF that results in a most even transfer of information below the resolution limit. We address not only the resolution of the instrument, but also the stability of the CTF in the presence of small disturbances in C 1 and C 3 . We show that resolution can be traded for stability in a rational and transparent fashion. These topics are discussed quantitatively for both weak-phase and strong-phase (or amplitude) objects. The results apply equally to instruments at high electron energy (TEM) and at very low electron energy (LEEM), as the basic optical properties of the imaging lenses are essentially identical. - Highlights: ► An optimized Contrast Transfer Function for aberration corrected electron microscopes is proposed. ► Based on the properties of the CTF near optimum settings, we address its stability. ► Over some range of parameters resolution can be traded for stability. ► These issues are addressed for weak-phase objects, as well as strong-phase and amplitude object. ► We compare our results with CTF settings previously proposed

  17. 3D high- and super-resolution imaging using single-objective SPIM.

    Science.gov (United States)

    Galland, Remi; Grenci, Gianluca; Aravind, Ajay; Viasnoff, Virgile; Studer, Vincent; Sibarita, Jean-Baptiste

    2015-07-01

    Single-objective selective-plane illumination microscopy (soSPIM) is achieved with micromirrored cavities combined with a laser beam-steering unit installed on a standard inverted microscope. The illumination and detection are done through the same objective. soSPIM can be used with standard sample preparations and features high background rejection and efficient photon collection, allowing for 3D single-molecule-based super-resolution imaging of whole cells or cell aggregates. Using larger mirrors enabled us to broaden the capabilities of our system to image Drosophila embryos.

  18. The added value of contrast enhanced spectral mammography in identification of multiplicity of suspicious lesions in dense breast

    Directory of Open Access Journals (Sweden)

    Amr Farouk Ibrahim Moustafa

    2018-03-01

    Full Text Available Objective: To evaluate the additive value of Contrast Enhanced Spectral Mammography (CESM in the preoperative assessment of malignant lesions in dense breast parenchyma regarding multiplicity. Material and methods: The study included 160 women having heterogeneous dense breast parenchyma (ACR c and d with suspicious lesions identified on sono mammography examination. All patients performed contrast enhanced spectral mammography to confirm or exclude lesion multiplicity. The number of lesions was calculated in the contrast high energy subtraction images with the reference standard being histopathological analysis. Results: Adding CESM to sono-mammography the accuracy in identifying multiple malignant lesion increased from 81.8% accuracy of sono-mammography up to 100% accuracy after adding CESM. Conclusion: Contrast enhanced spectral mammogram showed an added value in the preoperative assessment of breast masses increasing the accuracy of detection of lesions and multiplicity (multifocality and multi-centricity. Keywords: Breast cancer, Contrast enhanced spectral mammogram

  19. High Contrast CRT.

    Science.gov (United States)

    1980-02-01

    barium dioxide contains about 0.02% iron. For economical reasons, glass manufacturer’s probably use materials of lesser purity than reagent grade...otherwise the same procedure is followed. 2.4 Nonreflecting (NR) Film The NR film is a light abosrbing inhomogeneous film utilized to achieve a high...hour. No surface distortion of the disc occurred, thus ruling out any reaction between the carbon support plate and the glass disc that might have

  20. Development of microbubble contrast agents for high frequency ultrasound microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Se Jung; Kim, Eun A; Park, Sung Hoon; Lee, Hye Jin; Jun, Hong Young; Byun, Seung Jae; Yoon, Kwon Ha [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2007-05-15

    To develop optimal microbubble contrast agents (MBCAs) for performing ultrasound microscopy when examining small animals. We prepared three types of MBCAs. First, a mixture of three parts of 40% dextran and one part of 5% human serum albumin were sonicated with perfluorocarbon (PFC) (MB{sub 1}-D40A5P). Second, three parts of 40% dextran and one part of 1% human serum albumin were sonicated with PFC (MB{sub 2}-D40A1P). Third, all parts of 1% bovine serum albumin were sonicated with PFC (MB{sub 3}-A1P). We measured the microbubbles' sizes and concentrations with using image analysis software. The acoustic properties of the microbubbles were assessed both in vitro and in vivo. The majority of the MB{sub 1}-D40A5Ps had a diameter of 2-5 {mu} m, the mean diameter of the MB{sub 2}-D40A1Ps was 2.5 {mu} m, and the mean diameter of the MB{sub 3}-A1Ps was less than 2.0 {mu} m. Among the microbubbles, the MB{sub 1}-D40A5Ps and MB{sub 2}-D40A1Ps showed increased echogenicity in the abdominal vessels, but the duration of their contrast effect was less than 30 sec. On the contrary, the MB3-A1Ps exhibited strong enhancement in the vessels and their duration was greater than 120 sec. A microbubble contrast agent consisting of all parts of 1% serum albumin sonicated with PFC is an effective contrast agent for ultrasound microscopy.

  1. A finite-difference contrast source inversion method

    International Nuclear Information System (INIS)

    Abubakar, A; Hu, W; Habashy, T M; Van den Berg, P M

    2008-01-01

    We present a contrast source inversion (CSI) algorithm using a finite-difference (FD) approach as its backbone for reconstructing the unknown material properties of inhomogeneous objects embedded in a known inhomogeneous background medium. Unlike the CSI method using the integral equation (IE) approach, the FD-CSI method can readily employ an arbitrary inhomogeneous medium as its background. The ability to use an inhomogeneous background medium has made this algorithm very suitable to be used in through-wall imaging and time-lapse inversion applications. Similar to the IE-CSI algorithm the unknown contrast sources and contrast function are updated alternately to reconstruct the unknown objects without requiring the solution of the full forward problem at each iteration step in the optimization process. The FD solver is formulated in the frequency domain and it is equipped with a perfectly matched layer (PML) absorbing boundary condition. The FD operator used in the FD-CSI method is only dependent on the background medium and the frequency of operation, thus it does not change throughout the inversion process. Therefore, at least for the two-dimensional (2D) configurations, where the size of the stiffness matrix is manageable, the FD stiffness matrix can be inverted using a non-iterative inversion matrix approach such as a Gauss elimination method for the sparse matrix. In this case, an LU decomposition needs to be done only once and can then be reused for multiple source positions and in successive iterations of the inversion. Numerical experiments show that this FD-CSI algorithm has an excellent performance for inverting inhomogeneous objects embedded in an inhomogeneous background medium

  2. Low-Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    Science.gov (United States)

    2017-10-01

    low- cost and high-throughput was a key element proposed for this project, which we believe will be of significant benefit to the patients suffering...Award Number: W81XWH-15-1-0272 TITLE: Low- Cost , High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI...STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the author(s

  3. 3.0 Tesla high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the pulmonary circulation: initial experience with a 32-channel phased array coil using a high relaxivity contrast agent.

    Science.gov (United States)

    Nael, Kambiz; Fenchel, Michael; Krishnam, Mayil; Finn, J Paul; Laub, Gerhard; Ruehm, Stefan G

    2007-06-01

    To evaluate the technical feasibility of high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with highly accelerated parallel acquisition at 3.0 T using a 32-channel phased array coil, and a high relaxivity contrast agent. Ten adult healthy volunteers (5 men, 5 women, aged 21-66 years) underwent high spatial resolution CE-MRA of the pulmonary circulation. Imaging was performed at 3 T using a 32-channel phase array coil. After intravenous injection of 1 mL of gadobenate dimeglumine (Gd-BOPTA) at 1.5 mL/s, a timing bolus was used to measure the transit time from the arm vein to the main pulmonary artery. Subsequently following intravenous injection of 0.1 mmol/kg of Gd-BOPTA at the same rate, isotropic high spatial resolution data sets (1 x 1 x 1 mm3) CE-MRA of the entire pulmonary circulation were acquired using a fast gradient-recalled echo sequence (TR/TE 3/1.2 milliseconds, FA 18 degrees) and highly accelerated parallel acquisition (GRAPPA x 6) during a 20-second breath hold. The presence of artifact, noise, and image quality of the pulmonary arterial segments were evaluated independently by 2 radiologists. Phantom measurements were performed to assess the signal-to-noise ratio (SNR). Statistical analysis of data was performed by using Wilcoxon rank sum test and 2-sample Student t test. The interobserver variability was tested by kappa coefficient. All studies were of diagnostic quality as determined by both observers. The pulmonary arteries were routinely identified up to fifth-order branches, with definition in the diagnostic range and excellent interobserver agreement (kappa = 0.84, 95% confidence interval 0.77-0.90). Phantom measurements showed significantly lower SNR (P < 0.01) using GRAPPA (17.3 +/- 18.8) compared with measurements without parallel acquisition (58 +/- 49.4). The described 3 T CE-MRA protocol in addition to high T1 relaxivity of Gd-BOPTA provides sufficient SNR to support highly accelerated parallel acquisition

  4. Contrast venography of the leg: diagnostic efficacy, tolerance, and complication rates with ionic and nonionic contrast media

    International Nuclear Information System (INIS)

    Bettmann, M.A.; Robbins, A.; Braun, S.D.; Wetzner, S.; Dunnick, N.R.; Finkelstein, J.

    1987-01-01

    A prospective, three-center study of two contrast agents for leg venography was performed to evaluate both the relative frequency of adverse effects and whether low-osmolality agents provided significant advantages for this procedure. Fifty-four patients were studied with the standard preparation (iothalamate meglumine) and 57 with a nonionic agent (iopamidol). Both were used at an iodine concentration of 200 mg/mL, and there were no differences in volume of contrast material, duration of infusion, percentage of positive studies, or overall diagnostic adequacy. Patient discomfort was less with iopamidol than with iothalamate (18% vs. 44%), although discomfort was generally mild in both groups. By objective follow-up studies, the frequency of postvenographic thrombosis was not significantly different in the two groups (8% vs. 9%). Contrast venography, then, had a low frequency of complications when either a dilute conventional or a low-osmolality agent was employed. Although the frequency of postvenographic thrombosis was low with both agents, patient discomfort was less with the low-osmolality formulation

  5. MRI and CT contrast media extravasation

    Science.gov (United States)

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H.; Prince, Martin R.

    2018-01-01

    Abstract Background: This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Methods: Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Results: Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Conclusion: Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT. PMID:29489663

  6. Color contributes to object-contour perception in natural scenes.

    Science.gov (United States)

    Hansen, Thorsten; Gegenfurtner, Karl R

    2017-03-01

    The magnitudes of chromatic and achromatic edge contrast are statistically independent and thus provide independent information, which can be used for object-contour perception. However, it is unclear if and how much object-contour perception benefits from chromatic edge contrast. To address this question, we investigated how well human-marked object contours can be predicted from achromatic and chromatic edge contrast. We used four data sets of human-marked object contours with a total of 824 images. We converted the images to the Derrington-Krauskopf-Lennie color space to separate chromatic from achromatic information in a physiologically meaningful way. Edges were detected in the three dimensions of the color space (one achromatic and two chromatic) and compared to human-marked object contours using receiver operating-characteristic (ROC) analysis for a threshold-independent evaluation. Performance was quantified by the difference of the area under the ROC curves (ΔAUC). Results were consistent across different data sets and edge-detection methods. If chromatic edges were used in addition to achromatic edges, predictions were better for 83% of the images, with a prediction advantage of 3.5% ΔAUC, averaged across all data sets and edge detectors. For some images the prediction advantage was considerably higher, up to 52% ΔAUC. Interestingly, if achromatic edges were used in addition to chromatic edges, the average prediction advantage was smaller (2.4% ΔAUC). We interpret our results such that chromatic information is important for object-contour perception.

  7. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  8. Front-End Light Source for aWaveform-Controlled High-Contrast Few-Cycle Laser System for High-Repetition Rate Relativistic Optics

    Directory of Open Access Journals (Sweden)

    Rodrigo Lopez-Martens

    2013-03-01

    Full Text Available We present the current development of an injector for a high-contrast, ultrashort laser system devoted to relativistic laser-plasma interaction in the few-cycle regime. The front-end is based on CEP-stabilized Ti:Sa CPA followed by XPW filter designed at the mJ level for temporal cleaning and shortening. Accurate characterization highlights the fidelity of the proposed injector. Measured CEP drift is 170 mrad rms.

  9. Pulsed EM Field Response of a Thin, High-Contrast, Finely Layered Structure With Dielectric and Conductive Properties

    NARCIS (Netherlands)

    De Hoop, A.T.; Jiang, L.

    2009-01-01

    The response of a thin, high-contrast, finely layered structure with dielectric and conductive properties to an incident, pulsed, electromagnetic field is investigated theoretically. The fine layering causes the standard spatial discretization techniques to solve Maxwell's equations numerically to

  10. Evaluation of contrast media submitted to ionizing radiation

    International Nuclear Information System (INIS)

    Pinho, Katia Elisa Prus; Gewehr, Pedro Miguel; Soboll, Danyel Scheidegger; Silva, Caroline Werner Pereira da; Barison, Andersson; Tilly Junior, Joao Gilberto

    2009-01-01

    Objective: the purpose of the present study was to investigate the influence of ionizing radiation from x-rays and gamma rays on the molecular structure stability of several radiologic contrast media employed in diagnostic imaging by means of 1 H and 1 3C nuclear magnetic resonance spectroscopy. Materials and methods: eight different types of iodinated contrast media (three ionic and five non-ionic) were exposed to x-rays and gamma rays irradiation. Subsequently, the 1 H and 1 3C{ 1 H} nuclear magnetic resonance spectra of these contrast media were collected. Results: the 1 H and 1 3C{ 1 H} nuclear magnetic resonance spectra of both ionic and non-ionic contrast media irradiated by x-rays or gamma rays demonstrated the absence of any alteration of the contrast media chemical composition. Conclusion: there is no problem in keeping contrast media inside examination rooms or close to radiological equipment. It is important to mention that, during the tests, the samples were directly irradiated, while in a radiology examination room, the irradiation is not direct and, therefore, radiation levels in these cases are much lower than those employed in the present study. (author)

  11. A survey of contrast media used in coronary angiograph

    International Nuclear Information System (INIS)

    Weikl, A.; Hubmann, M.

    1982-01-01

    In recent years, various contrast media have been developed for use in coronary angiography. These contrast media may be divided into ionic contrast media of high osmolality, those of low osmolality, and nonionic contrast materials. We conducted our own clinical studies with 40 patients. In random succession a standard contrast medium (ionic, of high osmolality) and a new-generation contrast medium (either nonionic or ionic with low osmolality) were injected into the right and left coronary arteries. After each injection we measured the systolic and diastolic blood pressure using a liquid-filled coronary catheter. In addition, the change in the length of the cardiac cycle was registered in terms of the R-R interval (in ms) and at the same time, leads I, II, and III of the ECG were recorded. We studied the influence of the various contrast media on the activity of ATPase in in vitro experiments, using Lasser and Lang's. When ionic contrast media of low osmolality and nonionic contrast media were utilized the heart rate showed no change. Disturbances of rhythm such as ventricular tachycardia or fibrillation were not observed. All of the contrast media used produced the same ECG changes. These changes can be ascribed to the inhibition of ATPase. The arterial blood pressure was lowered significantly only by ionic contrast media of high osmolality only. (orig.)

  12. Text accessibility by people with reduced contrast sensitivity.

    Science.gov (United States)

    Crossland, Michael D; Rubin, Gary S

    2012-09-01

    Contrast sensitivity is reduced in people with eye disease, and also in older adults without eye disease. In this article, we compare contrast of text presented in print and digital formats with contrast sensitivity values for a large cohort of subjects in a population-based study of older adults (the Salisbury Eye Evaluation). Contrast sensitivity values were recorded for 2520 adults aged 65 to 84 years living in Salisbury, Maryland. The proportion of the sample likely to be unable to read text of different formats (electronic books, newsprint, paperback books, laser print, and LED computer monitors) was calculated using published contrast reserve levels required to perform spot reading, to read with fluency, high fluency, and under optimal conditions. One percent of this sample had contrast sensitivity less than that required to read newsprint fluently. Text presented on an LED computer monitor had the highest contrast. Ninety-eight percent of the sample had contrast sensitivity sufficient for high fluent reading of text (at least 160 words/min) on a monitor. However, 29.6% were still unlikely to be able to read this text with optimal fluency. Reduced contrast of print limits text accessibility for many people in the developed world. Presenting text in a high-contrast format, such as black laser print on a white page, would increase the number of people able to access such information. Additionally, making text available in a format that can be presented on an LED computer monitor will increase access to written documents.

  13. Magnetic resonance imaging contrast agents: Overview and perspectives

    International Nuclear Information System (INIS)

    Yan Guoping; Robinson, Leslie; Hogg, Peter

    2007-01-01

    Magnetic resonance imaging (MRI) is a non-invasive clinical imaging modality, which has become widely used in the diagnosis and/or staging of human diseases around the world. Some MRI examinations include the use of contrast agents. The categorizations of currently available contrast agents have been described according to their effect on the image, magnetic behavior and biodistribution in the body, respectively. In this field, superparamagnetic iron oxide particles and soluble paramagnetic metal chelates are two main classes of contrast agents for MRI. This review outlines the research and development of MRI contrast agents. In future, the ideal MRI contrast agent will be focused on the neutral tissue- or organ-targeting materials with high relaxivity and specificity, low toxicity and side effects, suitable long intravascular duration and excretion time, high contrast enhancement with low dose in vivo, and with minimal cost

  14. Contrast Enhanced US in the Abdomen

    International Nuclear Information System (INIS)

    Chung, Yong Eun; Kim, Ki Whang

    2012-01-01

    Contrast enhanced ultrasound, which was introduced in 1996, has been widely used in Europe and Eastern Asia. Ultrasound contrast agent can be classified as first generation and second generation, depending on the gas within the microbubble. With the first generation contrast agent, the high MI technique was used, and only intermittent scanning was possible due to destruction of the microbubble during scanning. Use of the second generation contrast agent with the low MI technique makes continuous scanning possible. Contrast enhanced US can be used in detection and differentiation of focal liver lesions. It is also helpful for monitoring of radiofrequency ablation and for targeting of US guided biopsy. Currently, because morphologic criteria alone may not reflect the response of the tumor to treatment, new criteria are needed for treatment evaluation after administration of anti-angiogenic agents. Contrast enhanced US could provide quantitative markers for evaluation of the response to treatment via use of dynamic contrast enhanced US. Due to cost-effectiveness, contrast enhanced US is not yet widely used in Korea; however, considering recent issues regarding contrast agent related adverse reaction, such as contrast induced nephropathy and nephrogenic systemic fibrosis, and radiation exposure, contrast enhanced US might be more widely used in Korea, as an alternative imaging modality in the future.

  15. The use of contrast agent for imaging biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J; Sopko, V; Jakubek, J [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ 12800 Prague 2 (Czech Republic); Weyda, F, E-mail: jiri.dammer@utef.cvut.cz [Biological center of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2011-01-15

    The technique of X-ray transmission imaging has been available for over a century and is still among the fastest and easiest approaches to the studies of internal structure of biological samples. Recent advances in semiconductor technology have led to the development of new types of X-ray detectors with direct conversion of interacting X-ray photon to an electric signal. Semiconductor pixel detectors seem to be specially promising; compared to the film technique, they provide single-quantum and real-time digital information about the objects being studied. We describe the recently developed radiographic apparatus, equipped with Medipix2 semiconductor pixel detector. The detector is used as an imager that counts individual photons of ionizing radiation, emitted by an X-ray tube (micro- or nano-focus FeinFocus). Thanks to the wide dynamic range of the Medipix2 detector and its high spatial resolution better than 1{mu}m, the setup is particularly suitable for radiographic imaging of small biological samples, including in-vivo observations with contrast agent (Optiray). Along with the description of the apparatus we provide examples of the use iodine contrast agent as a tracer in various insects as model organisms. The motivation of our work is to develop our imaging techniques as non-destructive and non-invasive. Microradiographic imaging helps detect organisms living in a not visible environment, visualize the internal biological processes and also to resolve the details of their body (morphology). Tiny live insects are an ideal object for our studies.

  16. Neutron and high-contrast X-ray micro-radiography as complementary tools for monitoring organosilicon consolidants in natural building stones

    Energy Technology Data Exchange (ETDEWEB)

    Slavíková, Monika, E-mail: Monika.Slavikova@vscht.cz [Department of Chemical Technology of Monuments Conservation, Institute of Chemical Technology in Prague, Prague 6 CZ-16628 (Czech Republic); Krejčí, František [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Prague 2 CZ-12800 (Czech Republic); Kotlík, Petr [Department of Chemical Technology of Monuments Conservation, Institute of Chemical Technology in Prague, Prague 6 CZ-16628 (Czech Republic); Jakůbek, Jan [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Prague 2 CZ-12800 (Czech Republic); Tomandl, Ivo; Vacík, Jiří [Nuclear Physics Institute, Academy of Sciences of the Czech Republic, CZ-25800, Rez Near Prague (Czech Republic)

    2014-11-01

    The monitoring of consolidants and other treatment product in stones is currently of great importance in various restoration studies. We use neutron and high-contrast X-ray micro-radiography as complementary non-destructive techniques for monitoring of organosilicon consolidants in the Opuka stone. Thanks to different sensitivities of both techniques in relation to the elemental composition, the effect of addition of the contrast agent (3-iodopropyl)trimethoxysilane commonly used in stone consolidation monitoring with X-ray radiography is evaluated. As the addition of the contrast agent to the original consolidation product alters important parameters such as the penetration depth, the understanding of the behaviour of the modified consolidation mixture is essential for verification of the reliability of the method. By comparing results from both methods, the respective radiographs show consistency in terms of homogeneity and penetration depth for all investigated concentrations of the used contrast agent. The presented results further demonstrate that the application of the contrast agent apparently changes the penetration depth, but these changes are, especially for very low concentrations (up to 1%) for most of the studies needed, negligible.

  17. High-field, high-resolution, susceptibility-weighted magnetic resonance imaging: improved image quality by addition of contrast agent and higher field strength in patients with brain tumors

    International Nuclear Information System (INIS)

    Pinker, K.; Noebauer-Huhmann, I.M.; Szomolanyi, P.; Weber, M.; Grabner, G.; Trattnig, S.; Stavrou, I.; Knosp, E.; Hoeftberger, R.; Stadlbauer, A.

    2008-01-01

    To demonstrate intratumoral susceptibility effects in malignant brain tumors and to assess visualization of susceptibility effects before and after administration of the paramagnetic contrast agent MultiHance (gadobenate dimeglumine; Bracco Imaging), an agent known to have high relaxivity, with respect to susceptibility effects, image quality, and reduction of scan time. Included in the study were 19 patients with malignant brain tumors who underwent high-resolution, susceptibility-weighted (SW) MR imaging at 3 T before and after administration of contrast agent. In all patients, Multihance was administered intravenously as a bolus (0.1 mmol/kg body weight). MR images were individually evaluated by two radiologists with previous experience in the evaluation of pre- and postcontrast 3-T SW MR images with respect to susceptibility effects, image quality, and reduction of scan time. In the 19 patients 21 tumors were diagnosed, of which 18 demonstrated intralesional susceptibility effects both in pre- and postcontrast SW images, and 19 demonstrated contrast enhancement in both SW images and T1-weighted spin-echo MR images. Conspicuity of susceptibility effects and image quality were improved in postcontrast images compared with precontrast images and the scan time was also reduced due to decreased TE values from 9 min (precontrast) to 7 min (postcontrast). The intravenous administration of MultiHance, an agent with high relaxivity, allowed a reduction of scan time from 9 min to 7 min while preserving excellent susceptibility effects and image quality in SW images obtained at 3 T. Contrast enhancement and intralesional susceptibility effects can be assessed in one sequence. (orig.)

  18. The effect of intravenous contrast on SUV value in 18F-FDG PET/CT using diagnostic high energy CT

    International Nuclear Information System (INIS)

    Jeong, Young Jin; Kang, Do Young

    2006-01-01

    According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT - 120 kVp, 130 mAs) scan. Than contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET emission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in all patients. Also pathologic lesions were investigated. There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p < 0.001). The maxSUV was 1.1 ± 0.5 in PET images with CECT-corrected attenuation and 1.0 ± 0.5 in PET images with NCCT-corrected attenuation. The limit of agreement was 0.1 ± 0.3 in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 and segment 8 of the liver and spleen (p <0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p < 0.001). The maxSUV was 4.7 ± 2.0 in PET images with CECT-corrected attenuation and 4.4 ± 2.0 in PET images with NCCT- corrected attenuation. The limit of agreement was 0.4 ± 0.8 in Bland-Altman analysis. Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of

  19. Interferometric phase-contrast X-ray CT imaging of VX2 rabbit cancer at 35keV X-ray energy

    Science.gov (United States)

    Takeda, Tohoru; Wu, Jin; Tsuchiya, Yoshinori; Yoneyama, Akio; Lwin, Thet-Thet; Hyodo, Kazuyuki; Itai, Yuji

    2004-05-01

    Imaging of large objects at 17.7-keV low x-ray energy causes huge x-ray exposure to the objects even using interferometric phase-contrast x-ray CT (PCCT). Thus, we tried to obtain PCCT images at high x-ray energy of 35keV and examined the image quality using a formalin-fixed VX2 rabbit cancer specimen with 15-mm in diameter. The PCCT system consisted of an asymmetrically cut silicon (220) crystal, a monolithic x-ray interferometer, a phase-shifter, an object cell and an x-ray CCD camera. The PCCT at 35 keV clearly visualized various inner structures of VX2 rabbit cancer such as necrosis, cancer, the surrounding tumor vessels, and normal liver tissue. Besides, image-contrast was not degraded significantly. These results suggest that the PCCT at 35 KeV is sufficient to clearly depict the histopathological morphology of VX2 rabbit cancer specimen.

  20. High-speed Fourier transform profilometry for reconstructing objects having arbitrary surface colours

    International Nuclear Information System (INIS)

    Chen, Liang-Chia; Nguyen, Xuan Loc; Zhang, Fu-Hao; Lin, Tzeng-Yow

    2010-01-01

    In this paper, Fourier transform profilometry (FTP) using a colour fringe selection technique for accurate phase map reconstruction is newly proposed to overcome the limitation of FTP in measuring objects having arbitrary surface colours. The sinusoidal colour fringe pattern is encoded to form a unique colour pattern for projecting onto the object's surface, and its reflected deformed fringe image is taken using a triple-colour CCD camera and rapidly processed by the developed FTP method employing a novel band-pass filter. A new 3D vision system is capable of measuring objects with a high speed of up to 60 frames s −1 . To reconstruct the 3D profile of an object having arbitrary surface colours, an innovative strategy is developed to identify the colour channel of the detected fringe pattern with the best modulation transfer function (MTF) for retrieving accurate phase maps. The experimental results demonstrate that the system has the capability to acquire 3D maps at a high speed while the measurement accuracy of the developed method is substantially better than that of the traditional FTP method. By measuring the standard step heights in a repeatability test, it is confirmed that a maximum measured error can be controlled to less than 2.8% of the overall measuring depth range

  1. Neutral vs positive oral contrast in diagnosing acute appendicitis with contrast-enhanced CT: sensitivity, specificity, reader confidence and interpretation time

    Science.gov (United States)

    Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F

    2011-01-01

    Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365

  2. Effects of high iodine doses given parenterally as contrast medium on parameter of the pro/antioxidative balance

    International Nuclear Information System (INIS)

    Winkler, R.; Griebenow, S.; Scheidleder, B.; Bailer, H.

    2002-01-01

    The aim of this study was to investigate effects of high iodine doses given parenterally as contrast medium on parameters of lipid status and thyroid hormone status as well as on parameters of the pro/antioxidative balance of spa patients. 29 patients with a comparable indication who had to undergo an angiography were chosen. The blood parameters of these patients were determined before and after the angiographic treatment. No provable changes of the thyroid parameters f-T 3 , f-T 4 and TSH were found after the angiography. In case of enzyme activities, the protective enzymes SOD and GSHPX showed no changes, while the concentrations of peroxides and MDA were increased significantly. Corresponding to this, the total antioxidative status and the vitamin E level decreased significantly. Altogether these results stand for a moderate deterioration of the antioxidative protective potential by the highly iodine containing contrast medium. (author)

  3. Parametric based morphological transformation for contrast ...

    Indian Academy of Sciences (India)

    for contrast enhancement of color images in poor-lighting ... high and low mean brightness value, there is a significant change in the view of the enhanced ... The two most fundamental morphological operations dilation and erosion are defined by ..... Menotti David 2007 Multi-histogram equalization methods for contrast ...

  4. Comparative study of pneumocystography, positive contrast cystography and double contrast cystography in dogs

    International Nuclear Information System (INIS)

    Thibaut, J.; Parada, E.; Vargas, L.; Deppe, R.; Born, R.

    1997-01-01

    In order to compare three radiographic techniques: pneumocystography, positive contrast cystography and double contrast cystography, three series of 24 radiographs each in lateral and ventrodorsal projections were made. Six healthy adult male dogs with weight ranging between 7 and 16 kg were used. Food was withheld for 24 hours and two enemas were made before the series of radiographs were taken. Dogs were anaesthetized with sodium thiopental (20 mg/kg i.v.). The contrast medium was introduced through a urethral catheter. Pneumocystography was performed in the first series introducing air (10 ml/kg) in the bladder. Positive contrast cystography was performed in the second series introducing Hypaque M-60% diluted, contributing 100 mg of iodine per ml (10 ml/kg). In the double contrast cystography Hypaque M-60% diluted (10 ml) was introduced, in concentration of 150 mg of iodine per ml. Then air was introduced (10 ml/kg) through a catheter. Plates were taken in both projections at 1 and 10 minutes for each technique. The radiographic plates of each series were analized comparing the characteristics of radiographic density, outline and size. In neumocystography, positive contrast and double contrast cystography, the radiographic density was predominantly low, high and intermediate, respectively. The radiographic outline was mainly regular for the three techniques. With respect to bladder size, there was a decrease of height and an increase of length and width at 10 minutes. Comparing these three radiographic techniques, it can be concluded that the one that best outlines the bladder mucosa is double contrast. Pneumocystography provides the best image for opaque structures and cystography best shows the position of the urinary bladder [es

  5. A Review: Radiographic Iodinated Contrast Media-Induced Thyroid Dysfunction

    Science.gov (United States)

    Leung, Angela M.; Braverman, Lewis E.; Brent, Gregory A.; Pearce, Elizabeth N.

    2015-01-01

    Context: Thyroid hormone production is dependent on adequate iodine intake. Excess iodine is generally well-tolerated, but thyroid dysfunction can occur in susceptible individuals after excess iodine exposure. Radiological iodinated contrast media represent an increasingly common source of excess iodine. Objective: This review will discuss the thyroidal response after acute exposure to excess iodine; contrast iodine-induced thyroid dysfunction; risks of iodine-induced thyroid dysfunction in vulnerable populations, such as the fetus, neonate, and patients with impaired renal function; and recommendations for the assessment and treatment of contrast iodine-induced thyroid dysfunction. Methods: Data for this review were identified by searching PubMed, Google Scholar, and references from relevant articles from 1948 to 2014. Conclusions: With the increase in the use of computed tomography scans in the United States, there is increasing risk of contrast-induced thyroid dysfunction. Patients at risk of developing iodine-induced thyroid dysfunction should be closely monitored after receiving iodinated contrast media and should be treated as needed. PMID:25375985

  6. Spectroscopy of 10 γ -Ray BL Lac Objects at High Redshift

    Energy Technology Data Exchange (ETDEWEB)

    Paiano, Simona; Falomo, Renato [INAF, Osservatorio Astronomico di Padova, Vicolo dell’Osservatorio 5, I-35122 Padova (Italy); Landoni, Marco [INAF, Osservatorio Astronomico di Brera, Via E. Bianchi 46, I-23807 Merate (Italy); Treves, Aldo [Università degli Studi dell’Insubria, Via Valleggio 11, I-22100 Como (Italy); Scarpa, Riccardo [Instituto de Astrofisica de Canarias, C/O Via Lactea, s/n E-38205 La Laguna, Tenerife (Spain)

    2017-08-01

    We present optical spectra with high signal-to-noise ratio of 10 BL Lac objects detected at GeV energies by the Fermi satellite (3FGL catalog), which previous observations suggested are at relatively high redshift. The new observations, obtained at the 10 m Gran Telescopio Canarias, allowed us to find the redshift for J0814.5+2943 ( z = 0.703), and we can set a spectroscopic lower limit for J0008.0+4713 ( z > 1.659) and J1107.7+0222 ( z > 1.0735) on the basis of Mg ii intervening absorption features. In addition we confirm the redshifts for J0505.5+0416 ( z = 0.423) and J1450+5200 ( z > 2.470). Finally we contradict the previous z estimates for five objects (J0049.7+0237, J0243.5+7119, J0802.0+1005, J1109.4+2411, and J2116.1+3339).

  7. Short term high dose atorvastatin for the prevention of contrast-induced nephropathy in patients undergoing computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Hamid Sanei

    2014-09-01

    Full Text Available BACKGROUND: Statins are shown effective by some studies in preventing contrast-induced nephropathy (CIN. We evaluated the effectiveness of atorvastatin in the prevention of CIN in computed tomography angiography (CTA candidates. METHODS: This study was conducted on patients referring for elective CTA with normal renal function. Patients received atorvastatin (80 mg/day or placebo from 24 h before to 48 h after administration of the contrast material. Serum creatinine was measured before and 48 h after contrast material injection. CIN was defined as an increase in serum creatinine level of ≥ 0.5 mg/dl or ≥ 25% of the baseline creatinine. RESULTS: A total of 236 patients completed the study; 115 atorvastatin, 121 placebo, mean age = 58.40 ± 9.80 year, 68.6% male. Serum creatinine increased after contrast material injection in both the atorvastatin (1.00 ± 0.16-1.02 ± 0.15 mg/dl, P = 0.017 and placebo groups (1.03 ± 0.17-1.08 ± 0.18 mg/dl, P < 0.001. Controlling for age, gender, comorbidities, drug history, and baseline serum creatinine level, patients who received atorvastatin experienced less increase in serum creatinine after contrast material injection (beta = 0.127, P = 0.034. However, there was no difference between the atorvastatin and placebo groups in the incidence of CIN (4.3 vs. 5.0%, P = 0.535. CONCLUSION: In patients undergoing CTA, a short-term treatment with high dose atorvastatin is effective in preventing contrast-induced renal dysfunction, in terms of less increase in serum creatinine level after contrast material injection. Further trials including larger sample of patients and longer follow-ups are warranted.   Keywords: Kidney Diseases, Multidetector Computed Tomography, Contrast Media, Hydroxymethylglutaryl-CoA Reductase Inhibitors, Atorvastatin 

  8. Enhancement tuning and control for high dynamic range images in multi-scale locally adaptive contrast enhancement algorithms

    NARCIS (Netherlands)

    Cvetkovic, S.D.; Schirris, J.; With, de P.H.N.

    2009-01-01

    For real-time imaging in surveillance applications, visibility of details is of primary importance to ensure customer confidence. If we display High Dynamic-Range (HDR) scenes whose contrast spans four or more orders of magnitude on a conventional monitor without additional processing, results are

  9. Contrast sensitivity abnormalities in deaf individuals

    Directory of Open Access Journals (Sweden)

    Masoud Khorrami-Nejad

    2018-01-01

    Conclusion: Hearing impaired boys are at a greater risk for contrast sensitivity abnormalities than boys with normal hearing. The larger frequency of contrast sensitivity abnormalities in high spatial frequencies than in other frequencies may demonstrate greater defects in the central visual system compared with the periphery in individuals with hearing loss.

  10. Diagnosis of the hypothenar hammer syndrome by high-resolution contrast-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Winterer, J.T.; Ghanem, N.; Schaefer, O.; Lehnhardt, S.; Thuerl, C.; Laubenberger, J. [Department of Diagnostic Radiology, University of Freiburg, Hugstetter Strasse 55, 79106 Freiburg (Germany); Roth, M. [Center of Geriatric Medicine and Gerontology Freiburg, University of Freiburg, Hugstetter Strasse 55, 79106 Freiburg (Germany); Horch, R.E. [Department of Plastic and Hand Surgery, University of Freiburg, Hugstetter Strasse 55, 79106 Freiburg (Germany)

    2002-10-01

    Our objective was to describe the imaging features of hypothenar hammer syndrome using minimally invasive contrast-enhanced MR angiography in comparison with oscillography study. In five patients with hypothenar hammer syndrome Gd-BOPTA-enhanced elliptically reordered 3D pulse sequence MR was compared with oscillography findings and clinical symptoms focusing on angiographic appearance of vessel injury, distribution pattern of hand vasculature and joining branches between the radial and ulnar artery supply. All patients showed segmental occlusion at the site of trauma impact with varying involvement of the superficial palmar arch, common volar digital arteries. Embolic disease was present in 50% of patients and could be clearly identified with MRA. Good correspondence was found between angiographic appearance including the presence of collaterals, clinical symptoms and oscillography. Bilateral comparison was helpful in distinguishing between vessel variants and pathology. Bilateral Gd-BOPTA-enhanced MR angiography is a minimally invasive method to depict clearly the localization and extent of vessel injury in hypothenar hammer syndrome providing valuable information about distribution pattern of hand vasculature and presence of collaterals; however, no flow data can be obtained. (orig.)

  11. Diagnosis of the hypothenar hammer syndrome by high-resolution contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Winterer, J.T.; Ghanem, N.; Schaefer, O.; Lehnhardt, S.; Thuerl, C.; Laubenberger, J.; Roth, M.; Horch, R.E.

    2002-01-01

    Our objective was to describe the imaging features of hypothenar hammer syndrome using minimally invasive contrast-enhanced MR angiography in comparison with oscillography study. In five patients with hypothenar hammer syndrome Gd-BOPTA-enhanced elliptically reordered 3D pulse sequence MR was compared with oscillography findings and clinical symptoms focusing on angiographic appearance of vessel injury, distribution pattern of hand vasculature and joining branches between the radial and ulnar artery supply. All patients showed segmental occlusion at the site of trauma impact with varying involvement of the superficial palmar arch, common volar digital arteries. Embolic disease was present in 50% of patients and could be clearly identified with MRA. Good correspondence was found between angiographic appearance including the presence of collaterals, clinical symptoms and oscillography. Bilateral comparison was helpful in distinguishing between vessel variants and pathology. Bilateral Gd-BOPTA-enhanced MR angiography is a minimally invasive method to depict clearly the localization and extent of vessel injury in hypothenar hammer syndrome providing valuable information about distribution pattern of hand vasculature and presence of collaterals; however, no flow data can be obtained. (orig.)

  12. X-ray microscopy study of track membranes and biological objects

    International Nuclear Information System (INIS)

    Artioukov, I.A.; Levashov, V.E.; Struk, I.I.; Vinogradov, A.V.; Asadchikov, V.E.; Mchedlishvili, B.V.; Postnov, A.A.; Vilensky, A.I.; Zagorsky, D.L.; Gulimova, V.I.; Saveliev, S.V.; Kurohtin, A.N.; Popov, A.V.

    2000-01-01

    The development of two types of X-ray microscopy applying to the organic objects investigation (biological samples and polymer matrix) is reported. Polymer track membranes were investigated using Schwarzchild X-ray microscope with 20 nm wavelength. Pore diameters down to 0.2 μm were clearly imaged. Contact X-ray microscopy at 0.229 nm wavelength was used to obtain clear images of inner structure of native biological samples. High contrast together with the high resolution (about 2-3 μm) allowed us to use this method for quantitative analysis of demineralization process taking place in the skeleton of amphibious after several weeks of weightlessness on biosputnik board

  13. Low index contrast heterostructure photonic crystal cavities with high quality factors and vertical radiation coupling

    Science.gov (United States)

    Ge, Xiaochen; Minkov, Momchil; Fan, Shanhui; Li, Xiuling; Zhou, Weidong

    2018-04-01

    We report here design and experimental demonstration of heterostructure photonic crystal cavities resonating near the Γ point with simultaneous strong lateral confinement and highly directional vertical radiation patterns. The lateral confinement is provided by a mode gap originating from a gradual modulation of the hole radii. High quality factor resonance is realized with a low index contrast between silicon nitride and quartz. The near surface-normal directional emission is preserved when the size of the core region is scaled down. The influence of the cavity size parameters on the resonant modes is also investigated theoretically and experimentally.

  14. Low-dose quantitative phase contrast medical CT

    Science.gov (United States)

    Mittone, A.; Bravin, A.; Coan, P.

    2018-02-01

    X-ray computed tomography (CT) is a powerful and routinely used clinical diagnostic technique, which is well tolerated by patients, and which provides high-resolution images and volumetric information about the body. However, two important limitations still affect this examination procedure: (1) its low sensitivity with respect to soft tissues, and (2) the hazards associated with x-ray exposure. Conventional radiology is based on the detection of the different photon absorption properties that characterize biological tissues, and thus the obtainable image contrast from soft and/or similar tissues is intrinsically limited. In this scenario, x-ray phase contrast imaging (XPCI) has been extensively tested and proven to overcome some of the main issues surrounding standard x-ray imaging. In addition to the absorption signal, XPCI relies on detecting the phase shifts induced by an object. Interestingly, as the order of magnitude of the phase contrast is higher than that of absorption, XPCI can, in principle, offer higher sensitivity at lower radiation doses. However, other technical aspects may counterbalance this gain, and an optimized setup and image processing solutions need to be implemented. The work presented here describes the strategies and developments we have realized, with the aim of controlling the radiation dose for the highly sensitive and quantitative XPCI-CT. Different algorithms for the phase retrieval and CT reconstruction of the XPCI data are presented. The CT algorithms we have implemented, namely the equally sloped tomography and the dictionary learning method, allow the image quality to be preserved while reducing the number of angular projections required by a factor of five. The results applied to breast imaging report accurate reconstructions at clinically compatible doses of the 3D distribution of the refractive properties of full human organs obtained by using three different phase retrieval methods. The described methodologies and the

  15. Intra-observer agreement in single and joint double readings of contrast-enhanced breast MRI screening for women with high genetic breast cancer risks

    Directory of Open Access Journals (Sweden)

    Hugo C

    2013-04-01

    Full Text Available Objectives: To examine intra-observer reliability (IR for lesion detection on contrast-enhanced breast magnetic resonance images (MRI for screening women at high risk of breast cancer in single and joint double readings, without case selection. Methods: Contrast-enhanced breast MRIs were interpreted twice by the same independent reader and twice in joint readings. IR was assessed for lesion detection, normal MRI identification, mass, non-mass like enhancements (NMLE and focus characterisation, and BI-RADS assessment. Results: MRI examinations for 124 breasts, 65 women (mean age 43.4y were retrospectively reviewed with 110 lesions identified. Abnormal BIRADS (3-5 classifications were found for 52.3% in single readings and 58.5% in joint readings. Seven biopsies were performed for 4 histologically confirmed cancers. IR for BI-RADS classifications was good for single (0.63, 95% CI: 0.49-0.77, and joint readings (0.77, 95% CI: 0.61-0.93. IR for background parenchymal enhancement (BPE was moderate across single (0.53, 95% CI: 0.40-0.65 and joint readings (0.44, 95% CI: 0.33-0.56. IR for BI-RADS category according to each enhancement was poor for single (0.27, 95% CI: 0.10-0.44, and higher for joint readings, (0.58, 95% CI: 0.43-0.72. Conclusions: IR in BI-RADS breast assessments or BI-RADS lesion assessments are better with joint reading in screening for women with high genetic risks, in particular for abnormal MRI (BI-RADS 3, 4 and 5.

  16. Saline contrast hysterosonography in abnormal uterine bleeding : a systematic review and meta-analysis

    NARCIS (Netherlands)

    de Kroon, CD; de Bock, GH; Dieben, SWM; Jansen, FW

    2003-01-01

    Objective To assess the diagnostic accuracy of saline contrast hysterosonography in the evaluation of the uterine cavity in women complaining of abnormal uterine bleeding. Design A systematic review and meta-analysis of diagnostic studies that compared saline contrast hysterosonography to a gold

  17. Methodology for object-oriented real-time systems analysis and design: Software engineering

    Science.gov (United States)

    Schoeffler, James D.

    1991-01-01

    Successful application of software engineering methodologies requires an integrated analysis and design life-cycle in which the various phases flow smoothly 'seamlessly' from analysis through design to implementation. Furthermore, different analysis methodologies often lead to different structuring of the system so that the transition from analysis to design may be awkward depending on the design methodology to be used. This is especially important when object-oriented programming is to be used for implementation when the original specification and perhaps high-level design is non-object oriented. Two approaches to real-time systems analysis which can lead to an object-oriented design are contrasted: (1) modeling the system using structured analysis with real-time extensions which emphasizes data and control flows followed by the abstraction of objects where the operations or methods of the objects correspond to processes in the data flow diagrams and then design in terms of these objects; and (2) modeling the system from the beginning as a set of naturally occurring concurrent entities (objects) each having its own time-behavior defined by a set of states and state-transition rules and seamlessly transforming the analysis models into high-level design models. A new concept of a 'real-time systems-analysis object' is introduced and becomes the basic building block of a series of seamlessly-connected models which progress from the object-oriented real-time systems analysis and design system analysis logical models through the physical architectural models and the high-level design stages. The methodology is appropriate to the overall specification including hardware and software modules. In software modules, the systems analysis objects are transformed into software objects.

  18. Preliminary study of 3.0 T contrast-enhanced whole heart coronary MR angiography using 32-channel coils with high acceleration factor

    International Nuclear Information System (INIS)

    Yang Qi; Li Kuncheng; Du Xiangying; Ma Heng; An Jing; Li Han; Xu Dong; Bi Xiaoming; Li Debiao

    2010-01-01

    Objective: To evaluate the diagnostic accuracy of 3.0 T contrast enhanced (CE) whole-heart coronary MRA (CE MRA) using 32-channel coils with high acceleration factor. Methods: Sixty patients with suspected coronary artery disease who were scheduled for coronary angiography (CAG) underwent CE CMRA at 3.0 T MRI scanner. A 32-channel receiver coil was used for data acquisition. For image acquisition, an ECG triggered,navigator-gated, inversion-recovery prepared, segmented gradient-echo sequence was used with an acceleration factor of three in the phase-encoding direction using GRAPPA reconstruction. Gd-BOPTA (0.15 mmol/kg body weight) was intravenously administered at a rate of 0.3 ml/s. The diagnostic accuracy in detecting significant stenoses (≥50% of vessel lumen) was evaluated using χ 2 test with X-ray angiography as the reference. Results: Whole-heart CE CMRA was successfully completed in 56 patients who were scheduled for CAG. The averaged imaging time was (6.0±1.3) min. 3.0 T CE CMRA using 32 channel coils correctly identified significant CAD in 28 patients and correctly ruled out CAD in 23 patients. The sensitivity and specificity were 93.3% and 88.5% respectively. Conclusion: Combined with dedicated 32-channel coils, 3.0 T CE CMRA allows significant reduction in imaging speed and reduced dose of the contrast agent. These improvements resulted in substantially improved overall accuracy of CE CMRA in detecting coronary artery disease. (authors)

  19. Ultrasound-induced Gas Release from Contrast Agent Microbubbles

    NARCIS (Netherlands)

    Postema, M.A.B.; Postema, Michiel; Bouakaz, Ayache; Versluis, Michel; de Jong, N.

    2005-01-01

    We investigated gas release from two hard-shelled ultrasound contrast agents by subjecting them to high-mechanical index (MI) ultrasound and simultaneously capturing high-speed photographs. At an insonifying frequency of 1.7 MHz, a larger percentage of contrast bubbles is seen to crack than at 0.5

  20. Variational contrast enhancement guided by global and local contrast measurements for single-image defogging

    Science.gov (United States)

    Zhou, Li; Bi, Du-Yan; He, Lin-Yuan

    2015-01-01

    The visibility of images captured in foggy conditions is impaired severely by a decrease in the contrasts of objects and veiling with a characteristic gray hue, which may limit the performance of visual applications out of doors. Contrast enhancement together with color restoration is a challenging mission for conventional fog-removal methods, as the degrading effect of fog is largely dependent on scene depth information. Nowadays, people change their minds by establishing a variational framework for contrast enhancement based on a physically based analytical model, unexpectedly resulting in color distortion, dark-patch distortion, or fuzzy features of local regions. Unlike previous work, our method treats an atmospheric veil as a scattering disturbance and formulates a foggy image as an energy functional minimization to estimate direct attenuation, originating from the work of image denoising. In addition to a global contrast measurement based on a total variation norm, an additional local measurement is designed in that optimal problem for the purpose of digging out more local details as well as suppressing dark-patch distortion. Moreover, we estimate the airlight precisely by maximization with a geometric constraint and a natural image prior in order to protect the faithfulness of the scene color. With the estimated direct attenuation and airlight, the fog-free image can be restored. Finally, our method is tested on several benchmark and realistic images evaluated by two assessment approaches. The experimental results imply that our proposed method works well compared with the state-of-the-art defogging methods.

  1. RESTORATION OF WEAK PHASE-CONTRAST IMAGES RECORDED WITH A HIGH DEGREE OF DEFOCUS: THE"TWIN IMAGE" PROBLEM ASSOCIATED WITH CTF CORRECTION

    Energy Technology Data Exchange (ETDEWEB)

    Downing, Kenneth H.; Glaeser, Robert M.

    2008-03-28

    Relatively large values of objective-lens defocus must normally be used to produce detectable levels of image contrast for unstained biological specimens, which are generally weak phase objects. As a result, a subsequent restoration operation must be used to correct for oscillations in the contrast transfer function (CTF) at higher resolution. Currently used methods of CTF-correction assume the ideal case in which Friedel mates in the scattered wave have contributed pairs of Fourier components that overlap with one another in the image plane. This"ideal" situation may be only poorly satisfied, or not satisfied at all, as the particle size gets smaller, the defocus value gets larger, and the resolution gets higher. We have therefore investigated whether currently used methods of CTF correction are also effective in restoring the single-sideband image information that becomes displaced (delocalized) by half (or more) the diameter of a particle of finite size. Computer simulations are used to show that restoration either by"phase flipping" or by multiplying by the CTF recovers only about half of the delocalized information. The other half of the delocalized information goes into a doubly defocused"twin" image of the type produced during optical reconstruction of an in-line hologram. Restoration with a Wiener filter is effective in recovering the delocalized information only when the signal-to-noise ratio (S/N) is orders of magnitude higher than that which exists in low-dose images of biological specimens, in which case the Wiener filter approaches division by the CTF (i.e. the formal inverse). For realistic values of the S/N, however, the"twin image" problem seenwith a Wiener filter is very similar to that seen when either phase flipping or multiplying by the CTF are used for restoration. The results of these simulations suggest that CTF correction is a poor alternative to using a Zernike-type phase plate when imaging biological specimens, in which case the images can

  2. Effect of atorvastatin on preventing contrast-induced nephropathy

    Energy Technology Data Exchange (ETDEWEB)

    Dongya, Zhang; Jing, Zhu; Jianchang, Chen; Weiting, Xu; Xiaoyu, Luo; Liangping, Zhao [Dept of Cardiology, the Second Hospital Affiliated to Soochow University, Suzhou (China)

    2011-03-15

    Objective: To study the effects of atorvastatin on contrast-induced renal function and urinary protein change in patients undergoing diagnostic and therapeutic coronary intervention. Methods: Two hundred and forty-six patients who underwent coronary angiography or percutaneous coronary intervention (PCI) were randomized to receive atorvastatin (40 mg, qn, n=123) or no atorvastatin (n=123) treatment 3 days before coronary angiography. All patients received hydrated therapy. Serum creatinine (Scr), urinary {alpha}l-microglobulin ({alpha}{sub l}-MG), and urinary albumin (mALB) were checked for evidence of tubular or glomerular damage at start, and 36 to 48 hours after the administration of a radiocontrast agent. High-sensitive C-reactive protein (hsCRP) levels, urinary {alpha}{sub l}-MG/ urinary creatinine(Ucr) and mALB/ Ucr were also assessed at the same time. Creatinine clearance(Ccr) was calculated according to Cockcroft-Gault formulas basing on serum creatinine. Results: (1) In the control group and atorvastatin-treated group, comparison with the value before coronary angiography or PCI, urinary {alpha}{sub l}-MG/ Ucr, mALB/ Ucr, Scr and hsCRP significantly increased from 36 to 48 hours after angiography or PCI (P<0.05). Ccr significantly decreased from 36 to 48 hours after angiography or PCI (P<0.05). (2) Compared the atorvastatin-treated group, the values of hsCRP, urinary {alpha}{sub l}-MG/ Ucr significantly increased at the 2nd day after angiography or PCI in the control group (P<0.05), incidence of contrast induced nephropathy (CIN) significantly increased too (8.13% vs 0.81%, P<0.05). Conclusions: Contrast media induces light renal function damage. Pretreatment with atorvastatin 40 mg/qn for 3 days could significantly reduce procedural inflammatory reaction and prevent contrast-induced nephropathy. (authors)

  3. Objective evaluation of acute adverse events and image quality of gadolinium-based contrast agents (gadobutrol and gadobenate dimeglumine) by blinded evaluation. Pilot study.

    Science.gov (United States)

    Semelka, Richard C; Hernandes, Mateus de A; Stallings, Clifton G; Castillo, Mauricio

    2013-01-01

    The purpose was to objectively evaluate a recently FDA-approved gadolinium-based contrast agent (GBCA) in comparison to our standard GBCA for acute adverse events and image quality by blinded evaluation. Evaluation was made of a recently FDA-approved GBCA, gadobutrol (Gadavist; Bayer), in comparison to our standard GBCA, gadobenate dimeglumine (MultiHance; Bracco), in an IRB- and HIPAA-compliant study. Both the imaging technologist and patient were not aware of the brand of the GBCA used. A total of 59 magnetic resonance studies were evaluated (59 patients, 31 men, 28 women, age range of 5-85 years, mean age of 52 years). Twenty-nine studies were performed with gadobutrol (22 abdominal and 7 brain studies), and 30 studies were performed with gadobenate dimeglumine (22 abdominal and 8 brain studies). Assessment was made of acute adverse events focusing on objective observations of vomiting, hives, and moderate and severe reactions. Adequacy of enhancement was rated as poor, fair and good by one of two experienced radiologists who were blinded to the type of agent evaluated. No patient experienced acute adverse events with either agent. The target minor adverse events of vomiting or hives, and moderate and severe reactions were not observed in any patient. Adequacy of enhancement was rated as good for both agents in all patients. Objective, blinded evaluation is feasible and readily performable for the evaluation of GBCAs. This proof-of-concept study showed that both GBCAs evaluated exhibited consistent good image quality and no noteworthy adverse events. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Preservice teachers’ objectives and their experience of practical work

    Directory of Open Access Journals (Sweden)

    V. Nivalainen

    2013-01-01

    Full Text Available This study explores third-year preservice physics teachers’ (n=32 views concerning the objectives of practical work at school and university. Content analysis of their essays about practical work revealed not only the objectives of the practical work undertaken but also how they had experienced teaching as school and university students. The objectives most commonly referred to were related to the connections between theory and practice, motivation, understanding phenomena, learning how to observe, and learning how to report. In contrast, some objectives were recognized only rarely, which is an important issue for discussion as a future challenge. Preservice teachers’ positive experiences of practical work resulted from the successful implementation of practical work. According to our findings, practical work can in many cases be regarded as successful, especially when the participants understand the objectives of the teaching. In contrast, negative experiences reflected failures or difficulties in implementation. We conclude by suggesting that preservice teachers should be offered opportunities to reflect on their previous experiences and to see and experience in practice the advantages of practical work.

  5. Non-destructive characterisation of polymers and Al-alloys by polychromatic cone-beam phase contrast tomography

    International Nuclear Information System (INIS)

    Kastner, Johann; Plank, Bernhard; Requena, Guillermo

    2012-01-01

    X-ray computed tomography (XCT) has become a very important tool for the non-destructive characterisation of materials. Continuous improvements in the quality and performance of X-ray tubes and detectors have led to cone-beam XCT systems that can now achieve spatial resolutions down to 1 μm and even below. Since not only the amplitude but also the phase of an X-ray beam is altered while passing through an object, phase contrast effects can occur even for polychromatic sources when the spatial coherence due to a small focal spot size is high enough. This can lead to significant improvements over conventional attenuation-based X-ray computed tomography. Phase contrast can increase by edge enhancement the visibility of small structures and of features which are only slightly different in attenuation. We report on the possibilities of polychromatic cone-beam phase contrast tomography for non-destructive characterisation of materials. A carbon fibre-reinforced polymer and the Al-alloys AlMg5Si7 and AlSi18 were investigated with high resolution cone-beam X-ray computed tomography with a polychromatic tube source. Under certain conditions strong phase contrast resulting in an upward and downward overshooting of the grey values across edges was observed. The phase effects are much stronger for the polymer than for the Al-alloys. The influence on the phase contrast of the parameters, including source-detector distance, focal spot size and tube acceleration voltage is presented. Maximum phase contrast was observed for a maximum distance between the source and the detector, for a low voltage and a minimum focal spot size at the X-ray source. The detectability of the different phases is improved by the edge enhancement and the resulting improvement of sharpness. Thus, a better segmentation of the carbon fibres in the fibre-reinforced polymer and of the Mg 2 Si-phase in the AlMg5Si7-alloy is achieved. Primary and eutectic Si cannot be detected by attenuation-based X

  6. 3D non-contrast-enhanced ECG-gated MR angiography of the lower extremities with dual-source radiofrequency transmission at 3.0 T: Intraindividual comparison with contrast-enhanced MR angiography in PAOD patients.

    Science.gov (United States)

    Rasper, Michael; Wildgruber, Moritz; Settles, Marcus; Eckstein, Hans-Henning; Zimmermann, Alexander; Reeps, Christian; Rummeny, Ernst J; Huber, Armin M

    2016-09-01

    To compare prospectively image quality and diagnostic confidence of flow-sensitive 3D turbo spin echo (TSE)-based non-contrast-enhanced MR angiography (NE-MRA) at 3.0 T using dual-source radiofrequency (RF) transmission with contrast-enhanced MRA (CE-MRA) in patients with peripheral arterial occlusive disease (PAOD). After consent was obtained, 35 patients (mean age 69.1 ± 10.6 years) with PAOD stage II-IV underwent NE-MRA followed by CE-MRA. Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was independently assessed by two radiologists and stenosis scoring was performed in 875 arterial segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for stenosis classification were calculated using CE-MRA as a reference method. Diagnostic agreement with CE-MRA was evaluated with Cohen's kappa statistics. NE-MRA provided high objective and subjective image quality at all levels of the arterial tree. Sensitivity and specificity for the detection of relevant stenosis was 91 % and 89 %, respectively; the NPV was 96 % and the PPV 78 %. There was good concordance between CE-MRA and NE-MRA in stenosis scoring. 3D electrocardiography (ECG)-gated TSE NE-MRA with patient-adaptive dual-source RF transmission at 3.0 T is a promising alternative for PAOD patients with contraindications for gadolinium-based contrast agents. It offers high sensitivity and NPV values in the detection of clinically relevant arterial stenosis. • Flow-sensitive TSE NE-MRA is a promising technique for PAOD evaluation. • Diagnostic accuracy is comparable to contrast-enhanced MRA. • NE-MRA eliminates the risk of NSF in patients with renal insufficiency. • Costs arising from the use of contrast agents can be avoided.

  7. Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds.

    Science.gov (United States)

    Haider, Clifton R; Borisch, Eric A; Glockner, James F; Mostardi, Petrice M; Rossman, Phillip J; Young, Phillip M; Riederer, Stephen J

    2010-10-01

    High temporal and spatial resolution is desired in imaging of vascular abnormalities having short arterial-to-venous transit times. Methods that exploit temporal correlation to reduce the observed frame time demonstrate temporal blurring, obfuscating bolus dynamics. Previously, a Cartesian acquisition with projection reconstruction-like (CAPR) sampling method has been demonstrated for three-dimensional contrast-enhanced angiographic imaging of the lower legs using two-dimensional sensitivity-encoding acceleration and partial Fourier acceleration, providing 1mm isotropic resolution of the calves, with 4.9-sec frame time and 17.6-sec temporal footprint. In this work, the CAPR acquisition is further undersampled to provide a net acceleration approaching 40 by eliminating all view sharing. The tradeoff of frame time and temporal footprint in view sharing is presented and characterized in phantom experiments. It is shown that the resultant 4.9-sec acquisition time, three-dimensional images sets have sufficient spatial and temporal resolution to clearly portray arterial and venous phases of contrast passage. It is further hypothesized that these short temporal footprint sequences provide diagnostic quality images. This is tested and shown in a series of nine contrast-enhanced MR angiography patient studies performed with the new method.

  8. Anisotropic photoconductivity and current deflection induced in Bi12SiO20 by high contrast interference pattern

    DEFF Research Database (Denmark)

    Kukhtarev, N.V.; Lyuksyutov, S; Buchhave, Preben

    1996-01-01

    We have predicted and observed an anisotropic photocurrent induced in the cubic crystal Bi/sub 12/SiO/sub 20/ by a high-contrast interference pattern. The transverse current detected when the interference pattern is tilted is caused by deflection of the direct current generated by an external...

  9. Adriamycin nephrosis and contrast media

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Golman, K.; Hemmingsen, L.; Larsen, S.; Skaarup, P.; Koebenhavns Amts Sygehus, Herlev; Koebenhavns Amts Sygehus, Herlev; Centralsygehuset, Nykoebing Falster; Malmoe Allmaenna Sjukhus

    1990-01-01

    Urine profiles (albumin, glucose, NAG, LDH, GGT and sodium) were followed for 9 days after intravenous injection of either diatrizoate, iohexol, or saline in 27 Wistar rats with nephrosis induced by Adriamycin 42 days before. Another 9 rats exposed to neither Adriamycin nor contrast media served as controls. None of the contrast media caused further increased albuminuria of significance, whereas both induced significantly increased excretion of all 5 tubular components. The excretion of NAG and sodium was significantly higher following diatrizoate than following iohexol. From 24 h post injection there was no significantly greater excretion of any of the components after either diatrizoate or iohexol than after saline among the rats given Adriamycin. At the end of day 9 after contrast medium injection neither serum sodium, potassium, glucose, urea, creatinine, nor albumin revealed any contrast media related changes. Kidney histology showed quantitatively larger lesions in kidneys exposed to Adriamycin and contrast media than in kidneys exposed to Adriamycin and saline. There were no differences between the two contrast media groups. It is thus concluded, that both high osmolar ionic and low osmolar non-ionic contrast media cause temporary tubular dysfunction but no further glomerular dysfunction in rats with nephrosis induced by Adriamycin. The histologic findings indicate that both media may worsen non-reversible renal lesions. (orig.)

  10. 64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model

    Science.gov (United States)

    Holalkere, N-S; Matthes, K; Kalva, S P; Brugge, W R; Sahani, D V

    2011-01-01

    Objective In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml–1) and high-concentration contrast media (HCCM) (370 mg I ml–1) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose. Methods CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml–1), Group B (HCCM; 370 mg I ml–1) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg–1) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test. Results The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose. Conclusion 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced. PMID:21081582

  11. Interaction between beans and objects

    International Nuclear Information System (INIS)

    Farias, J.T.

    1988-01-01

    The interaction between the X-ray beans and objects are studied, with the modification in the intensity. The kilovolt, the bundle filtration, the structure and composition of the patient and the quantity of scattered radiation are also described, as the main parameters for the contrast and for the dose of the patient. (C.G.C.) [pt

  12. Post-processing of high-contrast observations of exoplanets

    Directory of Open Access Journals (Sweden)

    Gladysz S.

    2011-07-01

    Full Text Available Post-processing of images delivered by the eXtreme Adaptive Optics (XAO instrumentation is a crucial step which can increase achievable contrast even by two orders of magnitude. In this communication I present a new class of algorithms for detection of extrasolar planets from a sequence of adaptive-optics-corrected images. In general, the methods discriminate between real sources and stellar PSF features based on statistics of recorded intensity. The methods are particularly useful in dealing with static speckles which are the greatest obstacle in detecting exoplanets.

  13. High-contrast differentiation resolution 3D imaging of rodent brain by X-ray computed microtomography

    Science.gov (United States)

    Zikmund, T.; Novotná, M.; Kavková, M.; Tesařová, M.; Kaucká, M.; Szarowská, B.; Adameyko, I.; Hrubá, E.; Buchtová, M.; Dražanová, E.; Starčuk, Z.; Kaiser, J.

    2018-02-01

    The biomedically focused brain research is largely performed on laboratory mice considering a high homology between the human and mouse genomes. A brain has an intricate and highly complex geometrical structure that is hard to display and analyse using only 2D methods. Applying some fast and efficient methods of brain visualization in 3D will be crucial for the neurobiology in the future. A post-mortem analysis of experimental animals' brains usually involves techniques such as magnetic resonance and computed tomography. These techniques are employed to visualize abnormalities in the brains' morphology or reparation processes. The X-ray computed microtomography (micro CT) plays an important role in the 3D imaging of internal structures of a large variety of soft and hard tissues. This non-destructive technique is applied in biological studies because the lab-based CT devices enable to obtain a several-micrometer resolution. However, this technique is always used along with some visualization methods, which are based on the tissue staining and thus differentiate soft tissues in biological samples. Here, a modified chemical contrasting protocol of tissues for a micro CT usage is introduced as the best tool for ex vivo 3D imaging of a post-mortem mouse brain. This way, the micro CT provides a high spatial resolution of the brain microscopic anatomy together with a high tissue differentiation contrast enabling to identify more anatomical details in the brain. As the micro CT allows a consequent reconstruction of the brain structures into a coherent 3D model, some small morphological changes can be given into context of their mutual spatial relationships.

  14. Electric field conjugation for ground-based high-contrast imaging: robustness study and tests with the Project 1640 coronagraph

    Science.gov (United States)

    Matthews, Christopher T.; Crepp, Justin R.; Vasisht, Gautam; Cady, Eric

    2017-10-01

    The electric field conjugation (EFC) algorithm has shown promise for removing scattered starlight from high-contrast imaging measurements, both in numerical simulations and laboratory experiments. To prepare for the deployment of EFC using ground-based telescopes, we investigate the response of EFC to unaccounted for deviations from an ideal optical model. We explore the linear nature of the algorithm by assessing its response to a range of inaccuracies in the optical model generally present in real systems. We find that the algorithm is particularly sensitive to unresponsive deformable mirror (DM) actuators, misalignment of the Lyot stop, and misalignment of the focal plane mask. Vibrations and DM registration appear to be less of a concern compared to values expected at the telescope. We quantify how accurately one must model these core coronagraph components to ensure successful EFC corrections. We conclude that while the condition of the DM can limit contrast, EFC may still be used to improve the sensitivity of high-contrast imaging observations. Our results have informed the development of a full EFC implementation using the Project 1640 coronagraph at Palomar observatory. While focused on a specific instrument, our results are applicable to the many coronagraphs that may be interested in employing EFC.

  15. One-step patterning of double tone high contrast and high refractive index inorganic spin-on resist

    Energy Technology Data Exchange (ETDEWEB)

    Zanchetta, E.; Della Giustina, G.; Brusatin, G. [Industrial Engineering Department and INSTM, Via Marzolo 9, 35131 Padova (Italy)

    2014-09-14

    A direct one-step and low temperature micro-fabrication process, enabling to realize large area totally inorganic TiO₂ micro-patterns from a spin-on resist, is presented. High refractive index structures (up to 2 at 632 nm) without the need for transfer processes have been obtained by mask assisted UV lithography, exploiting photocatalytic titania properties. A distinctive feature not shared by any of the known available resists and boosting the material versatility, is that the system behaves either as a positive or as negative tone resist, depending on the process parameters and on the development chemistry. In order to explain the resist double tone behavior, deep comprehension of the lithographic process parameters optimization and of the resist chemistry and structure evolution during the lithographic process, generally uncommon in literature, is reported. Another striking property of the presented resist is that the negative tone shows a high contrast up to 19, allowing to obtain structures resolution down to 2 μm wide. The presented process and material permit to directly fabricate different titania geometries of great importance for solar cells, photo-catalysis, and photonic crystals applications.

  16. Case with high cervical intramedullary hemangioblastoma associated with arteriovenous fistula. CT with simultaneous intravenous and intrathecal injection of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takao; Shoji, Shin-ichi; Yanagisawa, Nobuo; Tada, Tsuyoshi; Kobayashi, Naoki

    1988-02-01

    A 34-year-old woman complained of right hemiparesis and pain in the right hand. Routine X-ray of the cervical portion failed to reveal abnormal findings. CT with intravenous contrast medium showed a large high-density mass in the spinal canal at the level of C2. Right vertebral angiography showed a hypervascular mass. With simultaneous intravenous and intrathecal injections of contrast medium, the tumor was shown as a moderately high-density area and the parenchyma of cord as a thin low-density area surrounding the tumor stain on CT. These CT appearances led to the final diagnosis of high cervical intramedullary hemangioblastoma associated with arteriovenous fistulae. Pathological findings are typical of hemangioblastoma. The usefulness of CT in detecting the localization of hypervascular spinal cord lesions is stressed. (Namekawa, K.).

  17. Phase contrast STEM for thin samples: Integrated differential phase contrast

    International Nuclear Information System (INIS)

    Lazić, Ivan; Bosch, Eric G.T.; Lazar, Sorin

    2016-01-01

    It has been known since the 1970s that the movement of the center of mass (COM) of a convergent beam electron diffraction (CBED) pattern is linearly related to the (projected) electrical field in the sample. We re-derive a contrast transfer function (CTF) for a scanning transmission electron microscopy (STEM) imaging technique based on this movement from the point of view of image formation and continue by performing a two-dimensional integration on the two images based on the two components of the COM movement. The resulting integrated COM (iCOM) STEM technique yields a scalar image that is linear in the phase shift caused by the sample and therefore also in the local (projected) electrostatic potential field of a thin sample. We confirm that the differential phase contrast (DPC) STEM technique using a segmented detector with 4 quadrants (4Q) yields a good approximation for the COM movement. Performing a two-dimensional integration, just as for the COM, we obtain an integrated DPC (iDPC) image which is approximately linear in the phase of the sample. Beside deriving the CTFs of iCOM and iDPC, we clearly point out the objects of the two corresponding imaging techniques, and highlight the differences to objects corresponding to COM-, DPC-, and (HA) ADF-STEM. The theory is validated with simulations and we present first experimental results of the iDPC-STEM technique showing its capability for imaging both light and heavy elements with atomic resolution and a good signal to noise ratio (SNR). - Highlights: • First DPC-based atomic resolution images of potential and charge density are obtained. • This is enabled by integration and differentiation of 2D DPC signals, respectively. • Integrated DPC (iDPC) based on 4 quadrant imaging is compared to iCOM imaging. • Noise analysis and comparison with standard STEM imaging modes is provided. • iDPC allows direct imaging of light (C, N, O …) and heavy (Ga, Au …) atoms together.

  18. Phase contrast STEM for thin samples: Integrated differential phase contrast

    Energy Technology Data Exchange (ETDEWEB)

    Lazić, Ivan, E-mail: ivan.lazic@fei.com; Bosch, Eric G.T.; Lazar, Sorin

    2016-01-15

    It has been known since the 1970s that the movement of the center of mass (COM) of a convergent beam electron diffraction (CBED) pattern is linearly related to the (projected) electrical field in the sample. We re-derive a contrast transfer function (CTF) for a scanning transmission electron microscopy (STEM) imaging technique based on this movement from the point of view of image formation and continue by performing a two-dimensional integration on the two images based on the two components of the COM movement. The resulting integrated COM (iCOM) STEM technique yields a scalar image that is linear in the phase shift caused by the sample and therefore also in the local (projected) electrostatic potential field of a thin sample. We confirm that the differential phase contrast (DPC) STEM technique using a segmented detector with 4 quadrants (4Q) yields a good approximation for the COM movement. Performing a two-dimensional integration, just as for the COM, we obtain an integrated DPC (iDPC) image which is approximately linear in the phase of the sample. Beside deriving the CTFs of iCOM and iDPC, we clearly point out the objects of the two corresponding imaging techniques, and highlight the differences to objects corresponding to COM-, DPC-, and (HA) ADF-STEM. The theory is validated with simulations and we present first experimental results of the iDPC-STEM technique showing its capability for imaging both light and heavy elements with atomic resolution and a good signal to noise ratio (SNR). - Highlights: • First DPC-based atomic resolution images of potential and charge density are obtained. • This is enabled by integration and differentiation of 2D DPC signals, respectively. • Integrated DPC (iDPC) based on 4 quadrant imaging is compared to iCOM imaging. • Noise analysis and comparison with standard STEM imaging modes is provided. • iDPC allows direct imaging of light (C, N, O …) and heavy (Ga, Au …) atoms together.

  19. Reconstruction of Double-Exposed Terahertz Hologram of Non-isolated Object

    Science.gov (United States)

    Hu, Jiaqi; Li, Qi; Chen, Guanghao

    2016-04-01

    When the non-isolated imaging objects are complex or critical imaging precision is required, single-exposure digital hologram technique may be insufficient. So in this paper, double-exposure method is adopted in 2.52-THz inline digital holography simulations and experiments. Experimental results indicate that, compared with the results reconstructed by single-exposure amplitude-constrained phase retrieval algorithm (S-APRA), double-exposure phase-constrained phase retrieval algorithm (D-PPRA) increases the contrast of the reconstruction image by 0.146 and double-exposure amplitude-constrained phase retrieval algorithm (D-APRA) increases the contrast by 0.225. In addition, when applied to non-isolated object reconstruction, phase retrieval algorithms with only amplitude constraint on the object plane work better than those with both amplitude and phase constraints.

  20. Phosphor plate mammography: contrast studies and clinical experience

    International Nuclear Information System (INIS)

    Chang, C.H.J.; Martin, N.L.; Templeton, A.W.; Cook, L.T.; Harrison, L.A.; McFadden, M.A.; Dwyer, S.J. III; Spicer, J.; Crystal, J.M.

    1992-01-01

    Mammography and accurate microcalcification detection require very good spatial resolution. We have compared the diagnostic capabilities of reduced-exposure, third-generation, 5 cycles/mm computed radiography (CR) phosphor plates with conventional screen-film in 67 patients. No difference in diagnostic accuracy was detected. The digital characteristics of storage phosphor plates erabled us to study the relationship between contrast and spatial resolution. We developed a computer program to identify a single 100 μm pixel in a digital image and assign various gray levels to that pixel. Using this model, we determined that, for our 5 cycles/mm CR system, the imaged contrast of a 100 μm object was 62% of the original contrast. Current 5 cycles/mm phosphor plate systems cannot adequately detect microcalcifications that approximate 100 μm or smaller unless a magnification technique is used. (orig.)

  1. Interaction between High-Level and Low-Level Image Analysis for Semantic Video Object Extraction

    Directory of Open Access Journals (Sweden)

    Andrea Cavallaro

    2004-06-01

    Full Text Available The task of extracting a semantic video object is split into two subproblems, namely, object segmentation and region segmentation. Object segmentation relies on a priori assumptions, whereas region segmentation is data-driven and can be solved in an automatic manner. These two subproblems are not mutually independent, and they can benefit from interactions with each other. In this paper, a framework for such interaction is formulated. This representation scheme based on region segmentation and semantic segmentation is compatible with the view that image analysis and scene understanding problems can be decomposed into low-level and high-level tasks. Low-level tasks pertain to region-oriented processing, whereas the high-level tasks are closely related to object-level processing. This approach emulates the human visual system: what one “sees” in a scene depends on the scene itself (region segmentation as well as on the cognitive task (semantic segmentation at hand. The higher-level segmentation results in a partition corresponding to semantic video objects. Semantic video objects do not usually have invariant physical properties and the definition depends on the application. Hence, the definition incorporates complex domain-specific knowledge and is not easy to generalize. For the specific implementation used in this paper, motion is used as a clue to semantic information. In this framework, an automatic algorithm is presented for computing the semantic partition based on color change detection. The change detection strategy is designed to be immune to the sensor noise and local illumination variations. The lower-level segmentation identifies the partition corresponding to perceptually uniform regions. These regions are derived by clustering in an N-dimensional feature space, composed of static as well as dynamic image attributes. We propose an interaction mechanism between the semantic and the region partitions which allows to

  2. How high is visual short-term memory capacity for object layout?

    Science.gov (United States)

    Sanocki, Thomas; Sellers, Eric; Mittelstadt, Jeff; Sulman, Noah

    2010-05-01

    Previous research measuring visual short-term memory (VSTM) suggests that the capacity for representing the layout of objects is fairly high. In four experiments, we further explored the capacity of VSTM for layout of objects, using the change detection method. In Experiment 1, participants retained most of the elements in displays of 4 to 8 elements. In Experiments 2 and 3, with up to 20 elements, participants retained many of them, reaching a capacity of 13.4 stimulus elements. In Experiment 4, participants retained much of a complex naturalistic scene. In most cases, increasing display size caused only modest reductions in performance, consistent with the idea of configural, variable-resolution grouping. The results indicate that participants can retain a substantial amount of scene layout information (objects and locations) in short-term memory. We propose that this is a case of remote visual understanding, where observers' ability to integrate information from a scene is paramount.

  3. Effective signaling of surface boundaries by L-vertices reflect the consistency of their contrast in natural images.

    Science.gov (United States)

    Vessel, Edward A; Biederman, Irving; Subramaniam, Suresh; Greene, Michelle R

    2016-07-01

    An L-vertex, the point at which two contours coterminate, provides highly reliable evidence that a surface terminates at that vertex, thus providing the strongest constraint on the extraction of shape from images (Guzman, 1968). Such vertices are pervasive in our visual world but the importance of a statistical regularity about them has been underappreciated: The contours defining the vertex are (almost) always of the same direction of contrast with respect to the background (i.e., both darker or both lighter). Here we show that when the two contours are of different directions of contrast, the capacity of the L-vertex to signal the termination of a surface, as reflected in object recognition, is markedly reduced. Although image statistics have been implicated in determining the connectivity in the earliest cortical visual stage (V1) and in grouping during visual search, this finding provides evidence that such statistics are involved in later stages where object representations are derived from two-dimensional images.

  4. Foreign Object Detection by Sub-Terahertz Quasi-Bessel Beam Imaging

    Directory of Open Access Journals (Sweden)

    Hyang Sook Chun

    2012-12-01

    Full Text Available Food quality monitoring, particularly foreign object detection, has recently become a critical issue for the food industry. In contrast to X-ray imaging, terahertz imaging can provide a safe and ionizing-radiation-free nondestructive inspection method for foreign object sensing. In this work, a quasi-Bessel beam (QBB known to be nondiffracting was generated by a conical dielectric lens to detect foreign objects in food samples. Using numerical evaluation via the finite-difference time-domain (FDTD method, the beam profiles of a QBB were evaluated and compared with the results obtained via analytical calculation and experimental characterization (knife edge method, point scanning method. The FDTD method enables a more precise estimation of the beam profile. Foreign objects in food samples, namely crickets, were then detected with the QBB, which had a deep focus and a high spatial resolution at 210 GHz. Transmitted images using a Gaussian beam obtained with a conventional lens were compared in the sub-terahertz frequency experimentally with those using a QBB generated using an axicon.

  5. High Dynamics and Precision Optical Measurement Using a Position Sensitive Detector (PSD in Reflection-Mode: Application to 2D Object Tracking over a Smart Surface

    Directory of Open Access Journals (Sweden)

    Ioan Alexandru Ivan

    2012-12-01

    Full Text Available When related to a single and good contrast object or a laser spot, position sensing, or sensitive, detectors (PSDs have a series of advantages over the classical camera sensors, including a good positioning accuracy for a fast response time and very simple signal conditioning circuits. To test the performance of this kind of sensor for microrobotics, we have made a comparative analysis between a precise but slow video camera and a custom-made fast PSD system applied to the tracking of a diffuse-reflectivity object transported by a pneumatic microconveyor called Smart-Surface. Until now, the fast system dynamics prevented the full control of the smart surface by visual servoing, unless using a very expensive high frame rate camera. We have built and tested a custom and low cost PSD-based embedded circuit, optically connected with a camera to a single objective by means of a beam splitter. A stroboscopic light source enhanced the resolution. The obtained results showed a good linearity and a fast (over 500 frames per second response time which will enable future closed-loop control by using PSD.

  6. The experimental study of oxygen contrast MR ventilation imaging

    International Nuclear Information System (INIS)

    Yang Jian; Guo Youmin; Wu Xiaoming; Xi Nong; Wang Jianguo; Zhu Li; Lei Xiaoyan; Xie Enyi

    2003-01-01

    Objective: To study the feasibility and basic technology of the oxygen contrast MR ventilation imaging in lung. Methods: Six canine lungs were scanned by using inversion recovery pulse sequence with turbo spin echo acquisition before and after inhalation of the 100% oxygen as T 1 contrast agent, and the T 1 values were measured. The contrast-to-noise ratio (CNR) for each inversion recovery time was compared and the relationship between arterial blood oxygen pressure (PaO 2 ) and T 1 relaxation rate was observed. Subtraction technique was employed in the postprocessing of pre- and post-oxygen conditions. Results: Molecular oxygen could shorten the pulmonary T 1 value (average 13.37%, t=2.683, P 1 value of pre- and post-oxygen conditions. The relaxtivity of T 1 resulted in excellent linear correlation (r 2 =0.9974) with PaO 2 . Through the subtraction of pre- and post-oxygen image, the oxygen contrast MR ventilation -image was obtained. Conclusion: The oxygen contrast MR ventilation imaging has the feasibility and clinical potential for the assessment of regional pulmonary function

  7. Correlation of double-contrast high-density barium enema, colonoscopy, and histology in children with special attention to disparities

    International Nuclear Information System (INIS)

    Stringer, D.A.; Sherman, P.M.; Jakowenko, N.

    1986-01-01

    Colonscopic and double-contrast high-density barium enema (DCBE) findings were correlated in 68 patients (39 boys and 29 girls) aged 6 months to 18 years (mean 11.6 years) evaluated over a 24-month period. There was excellent correlation in 53 patients (78.0%) and good correlation in another 3 (4.4%) who had identical diagnoses and only slightly differing extent of disease reported. In 2 of these, DCBE showed more extensive disease, confirmed histologically in 1. Distal colitis seen on colonoscopy as reddening and neovascularity was missed on DCBE in 6 patients. Colonoscopy and DEBE failed to show a polyp in 1 patient each. One patient who had a normal DCBE and colonoscopy demonstrated a histological abnormality, and 1 patient with an abnormality on histology and DCBE was normal on colonscopy. A disparity resulted from the time between procedures in 1 patient and observer error in another. This high correlation is far better than any previously reported in children, supporting the use of high-density barium sulfate and double-contrast barium enemas in pediatric patients. (orig.)

  8. High transmittance contrast in amorphous to hexagonal phase of Ge2Sb2Te5: Reversible NIR-window

    Science.gov (United States)

    Singh, Palwinder; Singh, A. P.; Kanda, Neetu; Mishra, Monu; Gupta, Govind; Thakur, Anup

    2017-12-01

    Ge2Sb2Te5 (GST) is one of the best phase change materials because of its splendid set of properties, viz., high thermal stability, fast crystallization speed, good endurance, scalability, and reliability. Phase transition [amorphous → face centered cubic (fcc) → hexagonal close packed (hcp)] of GST thin films with annealing was studied using X-ray diffraction. Thin films in amorphous, fcc, and hcp phases are highly, medium, and negligible transparent in the near infra-red region, respectively. The optical transmission in amorphous, fcc, and hcp phases is ˜92%, ˜46%, and ˜2%, respectively, at the wavelength of 2740 nm. At 2740 nm, a high transmission contrast (˜90%) is observed with phase transition from the amorphous to hcp phase. By utilizing large transmission contrast, it is demonstrated that GST can be availed as a potential candidate for reversible near infra-red-window. The sharp change in optical transmission with phase transition can be understood from the change in density of states in the valence band.

  9. Cloud object store for checkpoints of high performance computing applications using decoupling middleware

    Science.gov (United States)

    Bent, John M.; Faibish, Sorin; Grider, Gary

    2016-04-19

    Cloud object storage is enabled for checkpoints of high performance computing applications using a middleware process. A plurality of files, such as checkpoint files, generated by a plurality of processes in a parallel computing system are stored by obtaining said plurality of files from said parallel computing system; converting said plurality of files to objects using a log structured file system middleware process; and providing said objects for storage in a cloud object storage system. The plurality of processes may run, for example, on a plurality of compute nodes. The log structured file system middleware process may be embodied, for example, as a Parallel Log-Structured File System (PLFS). The log structured file system middleware process optionally executes on a burst buffer node.

  10. Cascade Boosting-Based Object Detection from High-Level Description to Hardware Implementation

    Directory of Open Access Journals (Sweden)

    K. Khattab

    2009-01-01

    Full Text Available Object detection forms the first step of a larger setup for a wide variety of computer vision applications. The focus of this paper is the implementation of a real-time embedded object detection system while relying on high-level description language such as SystemC. Boosting-based object detection algorithms are considered as the fastest accurate object detection algorithms today. However, the implementation of a real time solution for such algorithms is still a challenge. A new parallel implementation, which exploits the parallelism and the pipelining in these algorithms, is proposed. We show that using a SystemC description model paired with a mainstream automatic synthesis tool can lead to an efficient embedded implementation. We also display some of the tradeoffs and considerations, for this implementation to be effective. This implementation proves capable of achieving 42 fps for 320×240 images as well as bringing regularity in time consuming.

  11. High cardiac vagal control is related to better subjective and objective sleep quality.

    Science.gov (United States)

    Werner, Gabriela G; Ford, Brett Q; Mauss, Iris B; Schabus, Manuel; Blechert, Jens; Wilhelm, Frank H

    2015-03-01

    Cardiac vagal control (CVC) has been linked to both physical and mental health. One critical aspect of health, that has not received much attention, is sleep. We hypothesized that adults with higher CVC--operationalized by high-frequency heart rate variability (HF-HRV)--will exhibit better sleep quality assessed both subjectively (i.e., with Pittsburgh Sleep Quality Index) and objectively (i.e., with polysomnography). HF-HRV was measured in 29 healthy young women during an extended neutral film clip. Participants then underwent full polysomnography to obtain objective measures of sleep quality and HF-HRV during a night of sleep. As expected, higher resting HF-HRV was associated with higher subjective and objective sleep quality (i.e., shorter sleep latency and fewer arousals). HF-HRV during sleep (overall or separated by sleep phases) showed less consistent relationships with sleep quality. These findings indicate that high waking CVC may be a key predictor of healthy sleep. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    Science.gov (United States)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  13. Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography

    International Nuclear Information System (INIS)

    Diekmann, Felix; Bick, Ulrich

    2007-01-01

    Digital mammography is more and more replacing conventional mammography. Initial concerns about an inferior image quality of digital mammography have been largely overcome and recent studies even show digital mammography to be superior in women with dense breasts, while at the same time reducing radiation exposure. Nevertheless, an important limitation of digital mammography remains: namely, the fact that summation may obscure lesions in dense breast tissue. However, digital mammography offers the option of so-called advanced applications, and two of these, contrast-enhanced mammography and tomosynthesis, are promising candidates for improving the detection of breast lesions otherwise obscured by the summation of dense tissue. Two techniques of contrast-enhanced mammography are available: temporal subtraction of images acquired before and after contrast administration and the so-called dual-energy technique, which means that pairs of low/high-energy images acquired after contrast administration are subtracted. Tomosynthesis on the other hand provides three-dimensional information on the breast. The images are acquired with different angulations of the X-ray tube while the object or detector is static. Various reconstruction algorithms can then be applied to the set of typically nine to 28 source images to reconstruct 1-mm slices with a reduced risk of obscuring pathology. Combinations of both advanced applications have only been investigated in individual experimental studies; more advanced software algorithms and CAD systems are still in their infancy and have only undergone preliminary clinical evaluation. (orig.)

  14. Pulsed x-ray imaging of high-density objects using a ten picosecond high-intensity laser driver

    Science.gov (United States)

    Rusby, D. R.; Brenner, C. M.; Armstrong, C.; Wilson, L. A.; Clarke, R.; Alejo, A.; Ahmed, H.; Butler, N. M. H.; Haddock, D.; Higginson, A.; McClymont, A.; Mirfayzi, S. R.; Murphy, C.; Notley, M.; Oliver, P.; Allott, R.; Hernandez-Gomez, C.; Kar, S.; McKenna, P.; Neely, D.

    2016-10-01

    Point-like sources of X-rays that are pulsed (sub nanosecond), high energy (up to several MeV) and bright are very promising for industrial and security applications where imaging through large and dense objects is required. Highly penetrating X-rays can be produced by electrons that have been accelerated by a high intensity laser pulse incident onto a thin solid target. We have used a pulse length of 10ps to accelerate electrons to create a bright x-ray source. The bremsstrahlung temperature was measured for a laser intensity from 8.5-12×1018 W/cm2. These x-rays have sequentially been used to image high density materials using image plate and a pixelated scintillator system.

  15. Utilizing generalized autocalibrating partial parallel acquisition (GRAPPA) to achieve high-resolution contrast-enhanced MR angiography of hepatic artery: Initial experience in orthotopic liver transplantation candidates

    Energy Technology Data Exchange (ETDEWEB)

    Xu Pengju [Department of Radiology, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai (China)]. E-mail: xpjbfc@163.com; Yan Fuhua [Department of Radiology, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai (China)]. E-mail: yanfuhua@yahoo.com; Wang Jianhua [Department of Radiology, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai (China); Lin Jiang [Department of Radiology, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai (China); Fan Jia [Liver Cancer Institute, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai (China)

    2007-03-15

    Objective: To evaluate feasibility of using GRAPPA to acquire high-resolution 3D contrast-enhanced MR angiography (CE-MRA) of hepatic artery and value of GRAPPA for displaying vessels anatomy. Materials and methods: High-resolution CE-MRA using GRAPPA was performed in 67 orthotopic liver transplantation recipient candidates. Signal intensity (SI) and relative SI, i.e., Cv-ro (vessel-to-liver contrast) of the aorta and the hepatic common artery (HCA), were measured. The SI and the relative SI were compared and analyzed using T-test. For purpose of qualitative evaluation, the vessel visualization quality and the order of depicted hepatic artery branches were evaluated by two radiologists independently and assessed by weighted kappa analysis. The depiction of hepatic arterial anatomy and variations was evaluated, and results were correlated with the findings in surgery. Results: The mean SI values were 283.29 {+-} 65.07 (mean {+-} S.D.) for aorta and 283.16 {+-} 64.07 for HCA, respectively. The mean relative SI values were 0.698 {+-} 0.09 for aorta and 0.696 {+-} 0.09 for HCA, respectively. Homogeneous enhancement between aorta and HCA was confirmed by statistically insignificant differences (p-values were 0.89 for mean SI values and 0.12 for mean relative SI values, respectively). The average score for vessel visualization ranged from good to excellent for different artery segments. Overall interobserver agreement in the visualization of different artery segments was excellent (kappa value > 0.80). The distal intrahepatic segmental arteries were well delineated for majority of patients with excellent interobserver agreement. Normal hepatic arterial anatomy was correctly demonstrated in 53 patients, and arterial anomalies were accurately detected on high-resolution MRA image of all 14 patients. Conclusion: High-resolution hepatic artery MRA acquired using GRAPPA in a reproducible manner excellently depicts and delineates small vessels and can be routinely used for

  16. Diagnostic value of dynamic contrast-enhanced MRI for submucosal palatal tumors

    International Nuclear Information System (INIS)

    Matsuzaki, Hidenobu; Yanagi, Yoshinobu; Hara, Marina; Katase, Naoki; Hisatomi, Miki; Unetsubo, Teruhisa; Konouchi, Hironobu; Takenobu, Toshihiko

    2012-01-01

    Objectives: To evaluate the diagnostic value of dynamic contrast-enhanced MRI (DCE-MRI) for differentiating between benign and malignant tumors in the palate. Materials and methods: 26 patients with submucosal palatal tumors were preoperatively examined using DCE-MRI. Their maximum contrast index (CImax), time of CImax (Tmax), and washout ratios (WR300 and WR600) were determined from contrast index curves. The submucosal palatal tumors were divided into two groups according to their Tmax values: the early enhancement group (Tmax 2 = 0.92, P < 0.001). Conclusions: Tmax is a useful parameter for distinguishing between benign and malignant submucosal palatal tumors.

  17. Analysis of contrast and absorbed doses in mammography

    International Nuclear Information System (INIS)

    Augusto, F.M.; Ghilardi Netto, T.; Subtil, L.J.; Silva, R. da

    2001-01-01

    One of the great causes of mortality between women in the world is the breast cancer. The mammograms are the method most efficient to detect some cases of cancer of breast before this to be clinically concrete. The quality of a picture system must be determined by the ability to detect tissue soft masses, cyst or tumors, but also calcifications. This detection is directly connected with the contrast obtained in these pictures. This work has for objective to develop a method for the analysis of this contrast in mammograms verifying the doses referred to these mammograms and comparing them with national and international levels of reference. (author)

  18. Nephropathy after administration of iso-osmolar and low-osmolar contrast media

    DEFF Research Database (Denmark)

    Biondi-Zoccai, Giuseppe; Lotrionte, Marzia; Thomsen, Henrik S

    2014-01-01

    BACKGROUND/OBJECTIVES: Contrast-induced nephropathy (CIN) may be a severe complication to the administration of iodine-based contrast media for diagnostic or interventional procedure using radiation exposure. Whether there is a difference in nephrotoxic potential between the various agents...... is uncertain. We aimed to perform a systematic review and network meta-analysis of randomized trials on iodine-based contrast agents. METHODS: Randomized trials of low-osmolar or iso-osmolar contrast media were searched in CENTRAL, Google Scholar, MEDLINE/PubMed, and Scopus. Risk of CIN was appraised within...... a hierarchical Bayesian model computing absolute rates (AR) and odds ratios (OR) with 95% credibility intervals, and probability of being best (Pbest) for each agent. RESULTS: A total of 42 trials (10048 patients) were included focusing on 7 different iodine-based contrast media. Risk of CIN was similarly low...

  19. Applications of focused MeV light ion beams for high resolution channeling contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, D N; Breese, M B.H.; Prawer, S; Dooley, S P; Allen, M G; Bettiol, A A; Saint, A [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Ryan, C G [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1994-12-31

    The technique of Nuclear Microscopy, utilizing a focused ion probe of typically MeV H{sup +} or He{sup +} ions, can produce images where the contrast depends on typical Ion Beam Analysis (lBA) processes. The probe forming lens system usually utilizes strong focusing, precision magnetic quadrupole lenses and the probe is scanned over the target to produce images. Originally, this imaging technique was developed to utilize backscattered particles with incident beam currents typically of a few nA, and the technique became known as Channeling Contrast Microscopy (CCM). Recently, the technique has been developed further to utilize the forward scattering of ions incident along a major crystal axis in thin crystals. This technique is known as Channeling Scanning Transmission Ion Microscopy (CSTIM). Since nearly all incident ions are detected, CSTIM is highly efficient and very low beam currents are sufficient for imaging, typically as low as a few fA. This allows probes as small as 50 nm to be used. In this paper we briefly review the recent applications of these emerging techniques to a variety of single crystal materials (authors). 13 refs., 5 figs.

  20. Applications of focused MeV light ion beams for high resolution channeling contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, D.N.; Breese, M.B.H.; Prawer, S.; Dooley, S.P.; Allen, M.G.; Bettiol, A.A.; Saint, A. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Ryan, C.G. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1993-12-31

    The technique of Nuclear Microscopy, utilizing a focused ion probe of typically MeV H{sup +} or He{sup +} ions, can produce images where the contrast depends on typical Ion Beam Analysis (lBA) processes. The probe forming lens system usually utilizes strong focusing, precision magnetic quadrupole lenses and the probe is scanned over the target to produce images. Originally, this imaging technique was developed to utilize backscattered particles with incident beam currents typically of a few nA, and the technique became known as Channeling Contrast Microscopy (CCM). Recently, the technique has been developed further to utilize the forward scattering of ions incident along a major crystal axis in thin crystals. This technique is known as Channeling Scanning Transmission Ion Microscopy (CSTIM). Since nearly all incident ions are detected, CSTIM is highly efficient and very low beam currents are sufficient for imaging, typically as low as a few fA. This allows probes as small as 50 nm to be used. In this paper we briefly review the recent applications of these emerging techniques to a variety of single crystal materials (authors). 13 refs., 5 figs.

  1. The primary applications of Gd-DTPA as an oral negative gastrointestinal contrast agent for MRCP

    International Nuclear Information System (INIS)

    Chen Yanping; Zhang Xuelin; Cheng Guanxun; Chang Renmin; Zhang Yuzhong; Cang Peng; Xia Qiong

    2003-01-01

    Objective: Using oral Gd-DTPA as a negative contrast agent to null the bowel signal during MR cholangiopancreatography (MRCP) to improve the quality of MRCP. Methods: A phantom study was performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in MRCP. 15 patients suspected of biliary tract and pancreatic disease were performed with MRCP before and after using 250 ml oral contrast agents (1:5 diluted Gd-DTPA, 1.488 g/L). All MR images were acquired using a 1.5 T whole body MR scanner (Vision Plus, Siemens). MRCP was acquired using two-dimensional single slice fast spin-echo sequence and HASTE (half-fourier acquisition single-shot fast spin echo) sequence. Results: The phantom study showed that the dilution ratio 1:5 of Gd-DTPA oral contrast agent was best in decreasing the signal intensity both in T 2 WI (59.3%) and in HASTE sequence (82.45%). All the dilution ratio of Gd-DTPA oral contrast agent decreased the signal intensity up to 90% on single slice MRCP. In all the patients the high signal intensity from the stomach and intestinal fluid was completely suppressed. The depictions of common bile duct and pancreatic duct were markedly improved by the oral contrast agent (P<0.05). Conclusion: 1:5 diluted (1.488 g/L) oral MR contrast agent Gd-DTPA can be an effective and safe negative contrast agent in eliminating signal intensity of the gastrointestinal tract, thus improving the depiction of the biliary system in MRCP

  2. Current iodinated contrast media

    International Nuclear Information System (INIS)

    Stacul, F.

    2001-01-01

    The number of scientific papers on iodinated contrast media is declining. Indeed, comparative trials between high-osmolality and low-osmolality agents largely showed the higher safety and tolerability of the latter, and this is no longer a matter of discussion. Only financial constraints could prevent a total conversion to low-osmolality agents. Research comparing low-osmolality (nonionic monomers, ionic dimer) and iso-osmolality contrast media (nonionic dimers) are still ongoing. Both classes of nonionic compounds proved safer than the ionic dimer. The relative merits of nonionic monomers and nonionic dimers are a matter for debate, and criteria for a selective use of different agents for different procedures could be discussed. (orig.)

  3. Factors influencing contrast sensitivity function in myopic eyes.

    Directory of Open Access Journals (Sweden)

    Kazutaka Kamiya

    Full Text Available To evaluate the factors affecting the area under the log contrast sensitivity function (AULCSF in healthy myopic eyes.We retrospectively examined 201 eyes of 201 consecutive subjects (age, 31.8 ± 7.4 years (mean ± standard deviation with myopic refractive errors of -1.25 to -8.25 diopters (D. From the contrast sensitivity data, the area under the log contrast sensitivity function (AULCSF was calculated. Stepwise multiple regression analysis was used to assess the factors affecting the AULCSF.The mean AULSCF was 1.09 ± 0.09 (0.89 to 1.55. Explanatory variables relevant to the AULCSF were, in order of influence, the objective scattering index (OSI (p = 0.018, partial regression coefficient B =  -0.032 and logMAR CDVA (p = 0.022, B =  -0.209 (adjusted R(2 = 0.231. No significant correlation was seen with other clinical factors such as gender, manifest refraction, pupil size, lens density, corneal HOAs, or ocular HOAs.Although the great majority of the variance remains unexplained, eyes with lower OSI and better CDVA are more predisposed to show higher contrast sensitivity function. These results indicate that not only CDVA but also intraocular forward scattering may play some role in predicting the contrast sensitivity function in myopic subjects.

  4. Indication-related dosing for magnetic resonance contrast media

    International Nuclear Information System (INIS)

    Yuh, W.T.C.; Parker, J.R.; Carvlin, M.J.

    1997-01-01

    This presentation reviews the issue of contrast media dosing and imaging protocols for the optimal MR imaging detection and characterization of pathology. The cumulative clinical experience gained in performing contrast-enhanced MR examinations with gadolinium chelates indicates that a dose of 0.1 mmol/kg body weight provides safe and effective enhancement of most CNS pathology. Doses lower than 0.1 mmol/kg have been shown to be inadequate for delineating all but selected types of CNS pathology, such as masses with a high lesion to background ratio on post-contrast images (acoustic neuromas) or lesions located in areas in which the normal tissue very rapidly takes up contrast agent (e. g. microadenomas in the pituitary gland). Recent clinical studies have suggested a role for high dose gadolinium administration (up to 0.3 mmol/kg) for the optimal detection and delineation of cerebral metastases or other small or poorly enhancing lesions. Differences in the histopathologic characteristics (capillary permeability, vascularity, location, size) of specific diseased tissues may require varying doses or even a different contrast agent to be used for optimal imaging results. As new MR contrast agents and new scanning techniques are introduced, the specific diagnostic question posed will likely determine the choice of pulse sequence, contrast agent and dose used. (orig.)

  5. Efficient Computation of Casimir Interactions between Arbitrary 3D Objects

    International Nuclear Information System (INIS)

    Reid, M. T. Homer; Rodriguez, Alejandro W.; White, Jacob; Johnson, Steven G.

    2009-01-01

    We introduce an efficient technique for computing Casimir energies and forces between objects of arbitrarily complex 3D geometries. In contrast to other recently developed methods, our technique easily handles nonspheroidal, nonaxisymmetric objects, and objects with sharp corners. Using our new technique, we obtain the first predictions of Casimir interactions in a number of experimentally relevant geometries, including crossed cylinders and tetrahedral nanoparticles.

  6. Polymeric nanoparticles as OCT contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Al Rawashdeh, Wa' el [RWTH Aachen University, Experimental Molecular Imaging (Germany); Kray, Stefan [RWTH Aachen University, Institute for Semiconductor Electronics (Germany); Pich, Andrij; Pargen, Sascha; Balaceanu, Andreea [RWTH Aachen University, Interactive Material Research (DWI) (Germany); Lenz, Markus; Spoeler, Felix [RWTH Aachen University, Institute for Semiconductor Electronics (Germany); Kiessling, Fabian, E-mail: fkiessling@ukaachen.de; Lederle, Wiltrud [RWTH Aachen University, Experimental Molecular Imaging (Germany)

    2012-12-15

    In this study, the optical properties of two nano-sized polymer colloids in optical coherence tomography (OCT) were compared in vitro with respect to their potential use as contrast agents. We used two types of particles: compact hydrophobic spherical polystyrene (PS) particles and soft water-swollen nanogel (NG) particles both with grafted hydrophilic shell, both prepared at two different sizes (PS at 300 and 150 nm, NG at 300 and 200 nm). The OCT backscattering signals of the particles in a vessel-mimicking highly scattering agar/TiO{sub 2} phantom were compared on either number of particles or weight percent. Larger particles and higher concentrations produced higher OCT contrast. At each concentration tested, a markedly higher contrast was achieved by PS particles than NG particles. PS particles generated a markedly higher OCT contrast than the phantom at concentrations of at least 1 Multiplication-Sign 10{sup 10} or 0.1 % for PS 300 nm and at least 3 Multiplication-Sign 10{sup 11} particles/mL or 0.4 % for PS 150 nm. The contrast generated by NG 300 nm was above the phantom contrast at concentrations of at least 3 Multiplication-Sign 10{sup 11} particles/mL or 1 %, whereas NG 200 nm only at 4 %. At any given weight percent, the differences in OCT contrast between differently sized particles were much less evident than in the comparison based on particle number. PS 300 nm generated also a good contrast ex vivo on chicken muscle tissue. These results strongly suggest that PS spheres have strong potential as intravascular OCT contrast agent, while NG particles need further contrast enhancer for being used as OCT contrast agent.

  7. [Perception of objects and scenes in age-related macular degeneration].

    Science.gov (United States)

    Tran, T H C; Boucart, M

    2012-01-01

    Vision related quality of life questionnaires suggest that patients with AMD exhibit difficulties in finding objects and in mobility. In the natural environment, objects seldom appear in isolation. They appear in a spatial context which may obscure them in part or place obstacles in the patient's path. Furthermore, the luminance of a natural scene varies as a function of the hour of the day and the light source, which can alter perception. This study aims to evaluate recognition of objects and natural scenes by patients with AMD, by using photographs of such scenes. Studies demonstrate that AMD patients are able to categorize scenes as nature scenes or urban scenes and to discriminate indoor from outdoor scenes with a high degree of precision. They detect objects better in isolation, in color, or against a white background than in their natural contexts. These patients encounter more difficulties than normally sighted individuals in detecting objects in a low-contrast, black-and-white scene. These results may have implications for rehabilitation, for layout of texts and magazines for the reading-impaired and for the rearrangement of the spatial environment of older AMD patients in order to facilitate mobility, finding objects and reducing the risk of falls. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  8. Survey of high-velocity molecular gas in the vicinity of Herbig-Haro objects. I

    International Nuclear Information System (INIS)

    Edwards, S.; Snell, R.L.

    1983-01-01

    A survey of high-velocity molecular gas toward 49 Herbig-Haro objects is presented. Observations of the 12 CO J = 1-0 transition obtained with the 14 m telescope of the Five College Radio Astronomy Observatory reveal three new spatially extended high-velocity molecular outflows. One is in the NGC 1333 region near HH 12, and two are in the NGC 7129 region, the first near LkHα 234 and the second near a far-infrared source. The relationship between optical Herbin-Haro emission knots and large-scale motions of the ambient molecular material is investigated, and the properties of high-velocity molecular outflows in the vicinity of Herbig-Haro objects are discussed. Of 11 energetic outflows in the vicinity of Herbig-Haro objects, eight are found in four pairs separated by 0.2-1.0 pc. We estimate that energetic outflows characterized by mass loss rates > or =10 -7 M/sub sun/ yr -1 occur for at least 10 4 yr once in the lifetime of all stars with masses greater than 1M/sub sun/

  9. The Moving Group Targets of the SEEDS High-contrast Imaging Survey of Exoplanets and Disks: Results and Observations from the First Three Years

    NARCIS (Netherlands)

    Brandt, T.D.; et al., [Unknown; Thalmann, C.

    2014-01-01

    We present results from the first three years of observations of moving group (MG) targets in the Strategic Exploration of Exoplanets and Disks with Subaru (SEEDS) high-contrast imaging survey of exoplanets and disks using the Subaru telescope. We achieve typical contrasts of ~105 at 1'' and ~106

  10. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300)

    International Nuclear Information System (INIS)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D.

    2004-01-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  11. Laryngeal High-Speed Videoendoscopy: Sensitivity of Objective Parameters towards Recording Frame Rate

    Directory of Open Access Journals (Sweden)

    Anne Schützenberger

    2016-01-01

    Full Text Available The current use of laryngeal high-speed videoendoscopy in clinic settings involves subjective visual assessment of vocal fold vibratory characteristics. However, objective quantification of vocal fold vibrations for evidence-based diagnosis and therapy is desired, and objective parameters assessing laryngeal dynamics have therefore been suggested. This study investigated the sensitivity of the objective parameters and their dependence on recording frame rate. A total of 300 endoscopic high-speed videos with recording frame rates between 1000 and 15 000 fps were analyzed for a vocally healthy female subject during sustained phonation. Twenty parameters, representing laryngeal dynamics, were computed. Four different parameter characteristics were found: parameters showing no change with increasing frame rate; parameters changing up to a certain frame rate, but then remaining constant; parameters remaining constant within a particular range of recording frame rates; and parameters changing with nearly every frame rate. The results suggest that (1 parameter values are influenced by recording frame rates and different parameters have varying sensitivities to recording frame rate; (2 normative values should be determined based on recording frame rates; and (3 the typically used recording frame rate of 4000 fps seems to be too low to distinguish accurately certain characteristics of the human phonation process in detail.

  12. Three-dimensional phase-contrast X-ray microtomography with scanning–imaging X-ray microscope optics

    International Nuclear Information System (INIS)

    Takeuchi, Akihisa; Uesugi, Kentaro; Suzuki, Yoshio

    2013-01-01

    A novel three-dimensional X-ray microtomographic micro-imaging system which enables simultaneous measurement of differential phase contrast and absorption contrast has been developed. The optical system consists of a scanning microscope with one-dimensional focusing device and an imaging microscope with one-dimensional objective. A three-dimensional (3D) X-ray tomographic micro-imaging system has been developed. The optical system is based on a scanning–imaging X-ray microscope (SIXM) optics, which is a hybrid system consisting of a scanning microscope optics with a one-dimensional (1D) focusing (line-focusing) device and an imaging microscope optics with a 1D objective. In the SIXM system, each 1D dataset of a two-dimensional (2D) image is recorded independently. An object is illuminated with a line-focused beam. Positional information of the region illuminated by the line-focused beam is recorded with the 1D imaging microscope optics as line-profile data. By scanning the object with the line focus, 2D image data are obtained. In the same manner as for a scanning microscope optics with a multi-pixel detector, imaging modes such as phase contrast and absorption contrast can be arbitrarily configured after the image data acquisition. By combining a tomographic scan method and the SIXM system, quantitative 3D imaging is performed. Results of a feasibility study of the SIXM for 3D imaging are shown

  13. Comparative evaluation of positive contrast and double contrast gastrography in dogs

    International Nuclear Information System (INIS)

    Dileepkumar, K.M.; Rajankutty, K.; Sarada, Amma T.; Devanand, C.B.; Vijayan, N.

    2012-01-01

    A contrast radiography of stomach with oral barium sulphate suspension 25% (5 mL/kg b.wt positive contrast) and double contrast with oral barium sulphate 25% (3 mL/kg b.wt) followed by air (2 to 10 mL/kg b.wt, negative contrast) was done on six dogs to study the affections of stomach. Contrast radiography using barium sulphate alone was found satisfactory to identify most of the lesions of the stomach. Double contrast radiography using barium sulphate and air, required sedation to control the animals for proper administration. For the diagnosis of mucosal lesions, double contrast radiography was better than barium sulphate alone. Key words: Barium, Contrast radiography, Dog, Double contrast, Stomach

  14. Micro-radiography of biological samples with medical contrast agents

    International Nuclear Information System (INIS)

    Dammer, J.; Weyda, F.; Benes, J.; Sopko, V.; Gelbic, I.

    2013-01-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system

  15. Micro-radiography of biological samples with medical contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@lf1.cuni.cz [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Weyda, F. [Faculty of Science, University of South Bohemia, Branisovska 31, 370 05 Ceske Budejovice (Czech Republic); Benes, J. [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Sopko, V. [Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Gelbic, I. [Biology Centre, AS CR, Institute of Entomology, Department of Biochemistry and Physiology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2013-12-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system.

  16. Object-oriented Approach to High-level Network Monitoring and Management

    Science.gov (United States)

    Mukkamala, Ravi

    2000-01-01

    An absolute prerequisite for the management of large investigating methods to build high-level monitoring computer networks is the ability to measure their systems that are built on top of existing monitoring performance. Unless we monitor a system, we cannot tools. Due to the heterogeneous nature of the hope to manage and control its performance. In this underlying systems at NASA Langley Research Center, paper, we describe a network monitoring system that we use an object-oriented approach for the design, we are currently designing and implementing. Keeping, first, we use UML (Unified Modeling Language) to in mind the complexity of the task and the required model users' requirements. Second, we identify the flexibility for future changes, we use an object-oriented existing capabilities of the underlying monitoring design methodology. The system is built using the system. Third, we try to map the former with the latter. APIs offered by the HP OpenView system.

  17. Application of differential interference contrast with inverted microscopes to the in vitro perfused nephron.

    Science.gov (United States)

    Horster, M; Gundlach, H

    1979-12-01

    The study of in vitro perfused individual nephron segments requires a microscope which provides: (1) easy access to the specimen for measurement of cellular solute flux and voltage; (2) an image with high resolution and contrast; (3) optical sectioning of the object at different levels; and (4) rapid recording of the morphological phenomena. This paper describes an example of commercially available apparatus meeting the above requirements, and illustrates its efficiency. The microscope is of the inverted type (Zeiss IM 35) equipped with differential-interference-contrast (DIC) with a long working distance, and an automatically controlled camera system. The microscopic image exhibits cellular and intercellular details in the unstained transporting mammalian nephron segments despite their tubular structure and great thickness and makes obvious function-structure correlations (e.g. cell volume changes); luminal and contraluminal cell borders are well resolved for controlled microelectrode impalement.

  18. A hardware architecture for real-time shadow removal in high-contrast video

    Science.gov (United States)

    Verdugo, Pablo; Pezoa, Jorge E.; Figueroa, Miguel

    2017-09-01

    Broadcasting an outdoor sports event at daytime is a challenging task due to the high contrast that exists between areas in the shadow and light conditions within the same scene. Commercial cameras typically do not handle the high dynamic range of such scenes in a proper manner, resulting in broadcast streams with very little shadow detail. We propose a hardware architecture for real-time shadow removal in high-resolution video, which reduces the shadow effect and simultaneously improves shadow details. The algorithm operates only on the shadow portions of each video frame, thus improving the results and producing more realistic images than algorithms that operate on the entire frame, such as simplified Retinex and histogram shifting. The architecture receives an input in the RGB color space, transforms it into the YIQ space, and uses color information from both spaces to produce a mask of the shadow areas present in the image. The mask is then filtered using a connected components algorithm to eliminate false positives and negatives. The hardware uses pixel information at the edges of the mask to estimate the illumination ratio between light and shadow in the image, which is then used to correct the shadow area. Our prototype implementation simultaneously processes up to 7 video streams of 1920×1080 pixels at 60 frames per second on a Xilinx Kintex-7 XC7K325T FPGA.

  19. Does long-term object priming depend on the explicit detection of object identity at encoding?

    Directory of Open Access Journals (Sweden)

    Carlos Alexandre Gomes

    2015-03-01

    Full Text Available It is currently unclear whether objects have to be explicitly identified at encoding for reliable behavioural long-term object priming to occur. We conducted two experiments that investigated long-term object and non-object priming using a selective-attention encoding manipulation that reduces explicit object identification. In Experiment 1, participants either counted dots flashed within an object picture (shallow encoding or engaged in an animacy task (deep encoding at study, whereas, at test, they performed an object-decision task. Priming, as measured by reaction times, was observed for both types of encoding, and was of equivalent magnitude. In Experiment 2, non-object priming (faster reaction times for studied relative to unstudied non-objects was also obtained under the same selective-attention encoding manipulation as in Experiment 1, and the magnitude of the priming effect was equivalent between experiments. In contrast, we observed a linear decrement in recognition memory accuracy across conditions (deep encoding of Experiment 1 > shallow encoding Experiment 1 > shallow encoding of Experiment 2, suggesting that priming was not contaminated by explicit memory strategies. We argue that our results are more consistent with the identification/production framework than the perceptual/conceptual distinction, and we conclude that priming of pictures largely ignored at encoding can be subserved by the automatic retrieval of two types of instances: one at the motor-level and another at an object-decision level.

  20. Numerical Investigation of Vertical Cavity Lasers With High-Contrast Gratings Using the Fourier Modal Method

    DEFF Research Database (Denmark)

    Taghizadeh, Alireza; Mørk, Jesper; Chung, Il-Sug

    2016-01-01

    We explore the use of a modal expansion technique, Fourier modal method (FMM), for investigating the optical properties of vertical cavities employing high-contrast gratings (HCGs). Three techniques for determining the resonance frequency and quality factor (Q-factor) of a cavity mode are compared......, the scattering losses of several HCG-based vertical cavities with inplane heterostructures which have promising prospects for fundamental physics studies and on-chip laser applications, are investigated. This type of parametric study of 3D structures would be numerically very demanding using spatial...

  1. Refraction-contrast bone imaging using synchrotron radiation

    International Nuclear Information System (INIS)

    Mori, Koichi; Sekine, Norio; Sato, Hitoshi; Shikano, Naoto; Shimao, Daisuke; Shiwaku, Hideaki; Hyodo, Kazuyuki; Oka, Hiroshi

    2002-01-01

    The X-ray refraction-contrast imaging using synchrotron radiation with some X-ray energies is successfully performed at B120B2 of SPring-8. The refraction-contrast images of bone samples such as human dried proximal phalanx, wrist, upper cervical vertebrae and sella turcica and as mouse proximal femur using the synchrotron X-ray are always better in image contrast and resolution than those of the absorption-contrast images using the synchrotron X-ray and/or the conventional X-ray tube. There is much likeness in the image contrast and resolution of trabeculae bone in the human dried proximal phalanx between X-ray energy of 30 keV at sample-to-film distance of 1 m and those of 40, 50 keV at those of 4,5 m, respectively. High-energy refraction-contrast imaging with suitable sample-to-film distance could reduce the exposure dose in human imaging. In the refraction-contrast imaging of human wrist, upper cervcal vertebrae, sella turcica and mouse proximal femur using the synchrotron X-ray, we can obtain better image contrast and resolution to correctly extract morphological information for diagnosis corresponding to each of the clinical field than those of the absorption-contrast images. (author)

  2. An iterative method for near-field Fresnel region polychromatic phase contrast imaging

    Science.gov (United States)

    Carroll, Aidan J.; van Riessen, Grant A.; Balaur, Eugeniu; Dolbnya, Igor P.; Tran, Giang N.; Peele, Andrew G.

    2017-07-01

    We present an iterative method for polychromatic phase contrast imaging that is suitable for broadband illumination and which allows for the quantitative determination of the thickness of an object given the refractive index of the sample material. Experimental and simulation results suggest the iterative method provides comparable image quality and quantitative object thickness determination when compared to the analytical polychromatic transport of intensity and contrast transfer function methods. The ability of the iterative method to work over a wider range of experimental conditions means the iterative method is a suitable candidate for use with polychromatic illumination and may deliver more utility for laboratory-based x-ray sources, which typically have a broad spectrum.

  3. Invited Review Article: Methods for imaging weak-phase objects in electron microscopy

    International Nuclear Information System (INIS)

    Glaeser, Robert M.

    2013-01-01

    Contrast has traditionally been produced in electron-microscopy of weak phase objects by simply defocusing the objective lens. There now is renewed interest, however, in using devices that apply a uniform quarter-wave phase shift to the scattered electrons relative to the unscattered beam, or that generate in-focus image contrast in some other way. Renewed activity in making an electron-optical equivalent of the familiar “phase-contrast” light microscope is based in part on the improved possibilities that are now available for device microfabrication. There is also a better understanding that it is important to take full advantage of contrast that can be had at low spatial frequency when imaging large, macromolecular objects. In addition, a number of conceptually new phase-plate designs have been proposed, thus increasing the number of options that are available for development. The advantages, disadvantages, and current status of each of these options is now compared and contrasted. Experimental results that are, indeed, superior to what can be accomplished with defocus-based phase contrast have been obtained recently with two different designs of phase-contrast aperture. Nevertheless, extensive work also has shown that fabrication of such devices is inconsistent, and that their working lifetime is short. The main limitation, in fact, appears to be electrostatic charging of any device that is placed into the electron diffraction pattern. The challenge in fabricating phase plates that are practical to use for routine work in electron microscopy thus may be more in the area of materials science than in the area of electron optics

  4. Man-Made Object Extraction from Remote Sensing Imagery by Graph-Based Manifold Ranking

    Science.gov (United States)

    He, Y.; Wang, X.; Hu, X. Y.; Liu, S. H.

    2018-04-01

    The automatic extraction of man-made objects from remote sensing imagery is useful in many applications. This paper proposes an algorithm for extracting man-made objects automatically by integrating a graph model with the manifold ranking algorithm. Initially, we estimate a priori value of the man-made objects with the use of symmetric and contrast features. The graph model is established to represent the spatial relationships among pre-segmented superpixels, which are used as the graph nodes. Multiple characteristics, namely colour, texture and main direction, are used to compute the weights of the adjacent nodes. Manifold ranking effectively explores the relationships among all the nodes in the feature space as well as initial query assignment; thus, it is applied to generate a ranking map, which indicates the scores of the man-made objects. The man-made objects are then segmented on the basis of the ranking map. Two typical segmentation algorithms are compared with the proposed algorithm. Experimental results show that the proposed algorithm can extract man-made objects with high recognition rate and low omission rate.

  5. Incompatibility of Contrast Medium and Trisodium Citrate

    International Nuclear Information System (INIS)

    Delcour, Christian; Bruninx, Guy

    2013-01-01

    To test the compatibility of trisodium citrate, a catheter lock solution, with iodinated contrast medium. Iohexol, iobitridol, iodixanol, ioxaglate, ioxithalamate, iomeprol, and iopromide were tested. In all tests, 2 ml of contrast medium were mixed with 2 ml of trisodium citrate solution. Iodixanol and ioxaglate provoked a highly viscous gluelike precipitation when mixed with trisodium citrate. A brief transient precipitate was observed with iohexol, iomeprol, and ioxithalamate. Permanent precipitation occurred with iobitridol and iopromide. One must be aware of the potential for precipitation when contrast medium is mixed with trisodium citrate solution. Before trisodium citrate solution is injected, the catheter should be thoroughly flushed with saline if a contrast medium has previously been injected through it.

  6. Contrast model for three-dimensional vehicles in natural lighting and search performance analysis

    Science.gov (United States)

    Witus, Gary; Gerhart, Grant R.; Ellis, R. Darin

    2001-09-01

    Ground vehicles in natural lighting tend to have significant and systematic variation in luminance through the presented area. This arises, in large part, from the vehicle surfaces having different orientations and shadowing relative to the source of illumination and the position of the observer. These systematic differences create the appearance of a structured 3D object. The 3D appearance is an important factor in search, figure-ground segregation, and object recognition. We present a contrast metric to predict search and detection performance that accounts for the 3D structure. The approach first computes the contrast of the front (or rear), side, and top surfaces. The vehicle contrast metric is the area-weighted sum of the absolute values of the contrasts of the component surfaces. The 3D structure contrast metric, together with target height, account for more than 80% of the variance in probability of detection and 75% of the variance in search time. When false alarm effects are discounted, they account for 89% of the variance in probability of detection and 95% of the variance in search time. The predictive power of the signature metric, when calibrated to half the data and evaluated against the other half, is 90% of the explanatory power.

  7. Video Quality Assessment Using Spatio-Velocity Contrast Sensitivity Function

    Science.gov (United States)

    Hirai, Keita; Tumurtogoo, Jambal; Kikuchi, Ayano; Tsumura, Norimichi; Nakaguchi, Toshiya; Miyake, Yoichi

    Due to the development and popularization of high-definition televisions, digital video cameras, Blu-ray discs, digital broadcasting, IP television and so on, it plays an important role to identify and quantify video quality degradations. In this paper, we propose SV-CIELAB which is an objective video quality assessment (VQA) method using a spatio-velocity contrast sensitivity function (SV-CSF). In SV-CIELAB, motion information in videos is effectively utilized for filtering unnecessary information in the spatial frequency domain. As the filter to apply videos, we used the SV-CSF. It is a modulation transfer function of the human visual system, and consists of the relationship among contrast sensitivities, spatial frequencies and velocities of perceived stimuli. In the filtering process, the SV-CSF cannot be directly applied in the spatial frequency domain because spatial coordinate information is required when using velocity information. For filtering by the SV-CSF, we obtain video frames separated in spatial frequency domain. By using velocity information, the separated frames with limited spatial frequencies are weighted by contrast sensitivities in the SV-CSF model. In SV-CIELAB, the criteria are obtained by calculating image differences between filtered original and distorted videos. For the validation of SV-CIELAB, subjective evaluation experiments were conducted. The subjective experimental results were compared with SV-CIELAB and the conventional VQA methods such as CIELAB color difference, Spatial-CIELAB, signal to noise ratio and so on. From the experimental results, it was shown that SV-CIELAB is a more efficient VQA method than the conventional methods.

  8. An object-oriented classification method of high resolution imagery based on improved AdaTree

    International Nuclear Information System (INIS)

    Xiaohe, Zhang; Liang, Zhai; Jixian, Zhang; Huiyong, Sang

    2014-01-01

    With the popularity of the application using high spatial resolution remote sensing image, more and more studies paid attention to object-oriented classification on image segmentation as well as automatic classification after image segmentation. This paper proposed a fast method of object-oriented automatic classification. First, edge-based or FNEA-based segmentation was used to identify image objects and the values of most suitable attributes of image objects for classification were calculated. Then a certain number of samples from the image objects were selected as training data for improved AdaTree algorithm to get classification rules. Finally, the image objects could be classified easily using these rules. In the AdaTree, we mainly modified the final hypothesis to get classification rules. In the experiment with WorldView2 image, the result of the method based on AdaTree showed obvious accuracy and efficient improvement compared with the method based on SVM with the kappa coefficient achieving 0.9242

  9. Efficacy of atorvastatin on the prevention of contrast-induced acute kidney injury: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Liu L

    2018-03-01

    Full Text Available Ling-Yun Liu,1 Yang Liu,2 Mei-Yan Wu,2 Yan-Yan Sun,3 Fu-Zhe Ma2 1Department of Andrology, 2Department of Nephrology, the First Hospital of Jilin University, 3Department of Nephrology, the Fourth Hospital of Jilin University, Changchun, China Background: Results of studies on the efficacy of atorvastatin pretreatment on reducing the prevalence of contrast-induced acute kidney injury (CIAKI in patients undergoing coronary angiography (CAG or percutaneous coronary intervention (PCI have been controversial.Objective: We undertook a meta-analysis to evaluate the efficacy of atorvastatin on contrast-induced nephropathy (CIN after CAG or PCI.Materials and methods: We undertook a systematic search of electronic databases (PubMed, Embase, and the Cochrane Library up to June 2017. A meta-analysis was carried out including randomized controlled trials (RCTs that compared atorvastatin pretreatment with pretreatment with a low-dose statin or placebo for CIAKI prevention in patients undergoing CAG. The main endpoint was CIN prevalence.Results: Nine RCTs were included in our meta-analysis. Atorvastatin pretreatment reduced the prevalence of CIN significantly (odds ratio [OR] 0.46; 95% confidence interval [95% CI] 0.27–0.79; p=0.004. The benefit of high-dose atorvastatin pretreatment was consistent when compared with the control group (OR 0.45; 95% CI 0.21–0.95; p=0.04.Conclusion: At high doses, atorvastatin pretreatment was associated with a significant reduction in the prevalence of CIAKI in patients undergoing CAG. Pretreatment with high-dose atorvastatin could be employed to prevent CIAKI. Keywords: atorvastatin, contrast-induced acute kidney injury, coronary angiography, percutaneous coronary intervention, contrast-induced nephropathy, meta-analysis

  10. Experience of slowly infused high-iodine-dose contrast computed tomography (SHD) of intracranial tumors

    International Nuclear Information System (INIS)

    Muraoka, Kiyoaki; Numata, Hideharu; Hokama, Yasuo

    1983-01-01

    A study was done on 20 patients with intracranial tumors by means of the slowly infused high-iodine-dose (SHD) contrast-enhancement technique. An intravenous drip infusion of 300 ml of Angiografin was given for three hours. Computerized tomograms were taken 1 hour, (2 hours), and 3 hours after the beginning of the drip infusion. The authors divided the lesions into four groups by analyzing the sequential changes in CT numbers using a histograms or profile of the region of interest. In group I, additional lesions were visible on the SHD scan (one case of metastatic brain tumors from lung cancer). In group 2, lesions were better displayed on the SHD scan due to increased enhancement (17 cases). In group 3, SHD scans showed no change (2 cases of fibrous astrocytoma). In group 4, the enhancement was diminished, but the lesion per se was still clealy identifiable (no case). Finally, in 18 cases out of 20 (90%), an additional or better display of the lesion was detected on SHD enhanced CT. The rational for doing the SHD enhancement is to detect a lesion with a minimally impaired blood-brain barrier by exposing a prolonged high blood-iodine level, and so the scanning is delayed until detectable levels of the contrast medium have accumulated within the vascular-channel pool or extravascular space of the lesion. SHD enhancement is useful: I) for revealing any additional lesion in a metastatic brain tumor; 2) for better displaying an obscure lesion on a usual scan; 3) for differentiating the quality of the lesion (for example, malignancy or cyst formation), and 4) for predicting the prognosis of the lesion. (J.P.N.)

  11. Shoulder arthrography: comparison of morbidity after use of various contrast media

    International Nuclear Information System (INIS)

    Hall, F.M.; Goldberg, R.P.; Wyshak, G.; Kilcoyne, R.F.

    1985-01-01

    This prospective study compares immediate and delayed patient discomfort in 177 patients following shoulder arthrography using intraarticular combinations of metrizamide, meglumine/sodium diatrizoate, meglumine diatrizoate, lidocaine, epinephrine, and air. Patients receiving conventional ionic monomeric positive contrast media had a 60% (90/150) incidence of moderate or severe delayed exacerbation of their baseline symptoms; only 14% (3/21) of patients receiving metrizamide, a nonionic contrast medium had similar levels of postprocedural discomfort. Morbidity was somewhat diminished with the use of double-contrast (45%, 34/75) rather than single-contrast (75%, 56/75) examinations, and with avoidance of sodium-containing contrast agents or epinephrine. Nonionic or monovalent polymeric contrast media, despite their present high cost, may be the agents of choice if single-contrast arthrography is performed in joints associated with a high incidence of postprocedural pain

  12. Patient safety and adverse events in contrast medium examinations

    International Nuclear Information System (INIS)

    Enge, I.; Edgren, J.

    1989-01-01

    This volume contains six contributions dealing with the properties, safety and economic aspects (lower risks but higher costs of new low-osmonality contrast media compared to the older high-osmonality, ionic ones) of contrast media used in radiology, and risks involved in procedures for administering of radiologic contrast media. (H.W.). refs.; figs.; tabs

  13. Radiochromic film dosimetry of contrast-enhanced radiotherapy (CERT)

    International Nuclear Information System (INIS)

    Morris, Kevin N; Weil, Michael D; Malzbender, Rainer

    2006-01-01

    Contrast-enhanced radiotherapy (CERT) employs elevated concentrations of high-Z contrast media in targets to dramatically increase the absorbed dose of radiation relative to the surrounding tissues. However, it is difficult to measure the dose enhancement with routine clinical instruments because the photoelectrons and Auger electrons produced by the interaction of kilovoltage x-rays with the contrast agent travel extremely short distances. We have developed a technique utilizing unlaminated radiochromic film to measure the maximum dose enhancement factor attainable in solutions of contrast agent with iodine concentrations ranging from 0% to 37% (w/v). The films were also used to simultaneously measure the dose enhancement and beam attenuation through solutions containing 0%, 5% and 10% iodine (w/v). These depth-dose measurements were made in phantoms representing 3 cm targets located 0 and 4.8 cm deep in acrylic. Higher concentrations of contrast yielded greater dose enhancement and target-to-surface dose ratios, but caused more rapid attenuation of the beam as it traversed the target. The dose distribution across the entire target could be improved by employing multiple beams. These results, using concentrations of contrast that are clinically achievable by intratumoural injection, illustrate the potential of CERT for the specific delivery of high doses of radiation to targets at depth

  14. Simultaneous contrast: evidence from licking microstructure and cross-solution comparisons.

    Science.gov (United States)

    Dwyer, Dominic M; Lydall, Emma S; Hayward, Andrew J

    2011-04-01

    The microstructure of rats' licking responses was analyzed to investigate both "classic" simultaneous contrast (e.g., Flaherty & Largen, 1975) and a novel discrete-trial contrast procedure where access to an 8% test solution of sucrose was preceded by a sample of either 2%, 8%, or 32% sucrose (Experiments 1 and 2, respectively). Consumption of a given concentration of sucrose was higher when consumed alongside a low rather than high concentration comparison solution (positive contrast) and consumption of a given concentration of sucrose was lower when consumed alongside a high rather than a low concentration comparison solution (negative contrast). Furthermore, positive contrast increased the size of lick clusters while negative contrast decreased the size of lick clusters. Lick cluster size has a positive monotonic relationship with the concentration of palatable solutions and so positive and negative contrasts produced changes in lick cluster size that were analogous to raising or lowering the concentration of the test solution respectively. Experiment 3 utilized the discrete-trial procedure and compared contrast between two solutions of the same type (sucrose-sucrose or maltodextrin-maltodextrin) or contrast across solutions (sucrose-maltodextrin or maltodextrin-sucrose). Contrast effects on consumption were present, but reduced in size, in the cross-solution conditions. Moreover, lick cluster sizes were not affected at all by cross-solution contrasts as they were by same-solution contrasts. These results are consistent with the idea that simultaneous contrast effects depend, at least partially, on sensory mechanisms.

  15. Study of x-ray emission enhancement via high contrast femtosecond laser interacting with solid foil

    International Nuclear Information System (INIS)

    Chen, Liming; Kando, Masaki; Bulanov, S.V.; Koga, James K.; Tajima, Toshiki; Xu M.H.; Yuan X.H.; Li Y.T.; Dong Q.L.; Zhang J.

    2007-01-01

    We studied the hard x-ray emission and the Kα x-ray conversion efficiency (η K ) produced by 60 fs high contrast frequency doubled Ti: sapphire laser pulse focused on Cu foil target. Cu Kα photon emission obtained with second harmonic laser pulse is more intense than the case of fundamental laser pulse. The Cu η K shows strong dependence on laser nonlinearly skewed pulse shape and reaches the maximum value 4x10 -4 with 100 fs negatively skewed pulse. It shows the electron spectrum shaping contribute to the increase of η K . (author)

  16. Method for observing phase objects without halos and directional shadows

    Science.gov (United States)

    Suzuki, Yoshimasa; Kajitani, Kazuo; Ohde, Hisashi

    2015-03-01

    A new microscopy method for observing phase objects without halos and directional shadows is proposed. The key optical element is an annular aperture at the front focal plane of a condenser with a larger diameter than those used in standard phase contrast microscopy. The light flux passing through the annular aperture is changed by the specimen's surface profile and then passes through an objective and contributes to image formation. This paper presents essential conditions for realizing the method. In this paper, images of colonies formed by induced pluripotent stem (iPS) cells using this method are compared with the conventional phase contrast method and the bright-field method when the NA of the illumination is small to identify differences among these techniques. The outlines of the iPS cells are clearly visible with this method, whereas they are not clearly visible due to halos when using the phase contrast method or due to weak contrast when using the bright-field method. Other images using this method are also presented to demonstrate a capacity of this method: a mouse ovum and superimposition of several different images of mouse iPS cells.

  17. Integrative Analysis of High-throughput Cancer Studies with Contrasted Penalization

    Science.gov (United States)

    Shi, Xingjie; Liu, Jin; Huang, Jian; Zhou, Yong; Shia, BenChang; Ma, Shuangge

    2015-01-01

    In cancer studies with high-throughput genetic and genomic measurements, integrative analysis provides a way to effectively pool and analyze heterogeneous raw data from multiple independent studies and outperforms “classic” meta-analysis and single-dataset analysis. When marker selection is of interest, the genetic basis of multiple datasets can be described using the homogeneity model or the heterogeneity model. In this study, we consider marker selection under the heterogeneity model, which includes the homogeneity model as a special case and can be more flexible. Penalization methods have been developed in the literature for marker selection. This study advances from the published ones by introducing the contrast penalties, which can accommodate the within- and across-dataset structures of covariates/regression coefficients and, by doing so, further improve marker selection performance. Specifically, we develop a penalization method that accommodates the across-dataset structures by smoothing over regression coefficients. An effective iterative algorithm, which calls an inner coordinate descent iteration, is developed. Simulation shows that the proposed method outperforms the benchmark with more accurate marker identification. The analysis of breast cancer and lung cancer prognosis studies with gene expression measurements shows that the proposed method identifies genes different from those using the benchmark and has better prediction performance. PMID:24395534

  18. Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration

    International Nuclear Information System (INIS)

    Hwang, Jae-Yeon; Choo, Ki Seok; Choi, Yoon Young; Kim, Jin Hyeok; Ryu, Hwaseong; Kim, Yong-Woo; Jeon, Ung Bae; Nam, Kyung Jin; Han, Junhee

    2017-01-01

    Several recent studies showed the optimal contrast enhancement with a low-concentration and iso-osmolar contrast media in both adult and pediatric patients. However, low contrast media concentrations are not routinely used due to concerns of suboptimal enhancement of cardiac structures and small vessels. To evaluate the feasibility of using iso-osmolar contrast media containing a low iodine dose for CT cardiac angiography at 80 kilovolts (kVp) in neonates and infants. The iodixanol 270 group consisted of 79 CT scans and the iopromide 370 group of 62 CT scans in patients ≤1 year old. Objective measurement of the contrast enhancement was analyzed and contrast-to-noise ratios of the ascending aorta and left ventricle were calculated. Regarding subjective measurement, a four-point scale system was devised to evaluate degrees of contrast enhancement, image noise, motion artifact and overall image quality of each image set. Reader performance for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment was evaluated. Group objective and subjective measurements were nonsignificantly different. Overall sensitivity, specificity and diagnostic accuracy for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment were 42.8%, 59%, and 50%, respectively. The application of iodixanol 270 achieved optimal enhancement for performing pediatric cardiac CT angiography at 80 kVp in neonates and infants. Objective measurements of contrast enhancement and subjective image quality assessments were not statistically different in the iodixanol 270 and iopromide 370 groups. (orig.)

  19. Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae-Yeon [Pusan National University Yangsan Hospital, Department of Radiology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of); Pusan National University Yangsan Hospital, Research Institute for Convergence of Biomedical Science and Technology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of); Choo, Ki Seok; Choi, Yoon Young; Kim, Jin Hyeok; Ryu, Hwaseong; Kim, Yong-Woo; Jeon, Ung Bae; Nam, Kyung Jin [Pusan National University Yangsan Hospital, Department of Radiology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of); Han, Junhee [Pusan National University Yangsan Hospital, Division of Biostatistics, Research Institute for Convergence of Biomedical Science and Technology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of)

    2017-05-15

    Several recent studies showed the optimal contrast enhancement with a low-concentration and iso-osmolar contrast media in both adult and pediatric patients. However, low contrast media concentrations are not routinely used due to concerns of suboptimal enhancement of cardiac structures and small vessels. To evaluate the feasibility of using iso-osmolar contrast media containing a low iodine dose for CT cardiac angiography at 80 kilovolts (kVp) in neonates and infants. The iodixanol 270 group consisted of 79 CT scans and the iopromide 370 group of 62 CT scans in patients ≤1 year old. Objective measurement of the contrast enhancement was analyzed and contrast-to-noise ratios of the ascending aorta and left ventricle were calculated. Regarding subjective measurement, a four-point scale system was devised to evaluate degrees of contrast enhancement, image noise, motion artifact and overall image quality of each image set. Reader performance for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment was evaluated. Group objective and subjective measurements were nonsignificantly different. Overall sensitivity, specificity and diagnostic accuracy for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment were 42.8%, 59%, and 50%, respectively. The application of iodixanol 270 achieved optimal enhancement for performing pediatric cardiac CT angiography at 80 kVp in neonates and infants. Objective measurements of contrast enhancement and subjective image quality assessments were not statistically different in the iodixanol 270 and iopromide 370 groups. (orig.)

  20. Interactive Preference Learning of Utility Functions for Multi-Objective Optimization

    OpenAIRE

    Dewancker, Ian; McCourt, Michael; Ainsworth, Samuel

    2016-01-01

    Real-world engineering systems are typically compared and contrasted using multiple metrics. For practical machine learning systems, performance tuning is often more nuanced than minimizing a single expected loss objective, and it may be more realistically discussed as a multi-objective optimization problem. We propose a novel generative model for scalar-valued utility functions to capture human preferences in a multi-objective optimization setting. We also outline an interactive active learn...

  1. The 'humble' bubble: Contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Marshall, Gill; Sykes, Anne; Berry, Jonathan; Jonker, Leon

    2011-01-01

    The use of contrast-enhanced ultrasound (CEUS) is increasing within the field of medical imaging. Ultrasonic contrast agent (UCA) contain gas microbubbles similar in size to red corpuscles which provide highly reflective interfaces, enabling dynamic demonstration of echogenic streams of the contrast within the anatomical area of interest on real-time grey scale ultrasound. Longevity of the microbubbles has been improved by changing their composition. The application of CEUS in the UK continues to grow, bringing it into territories historically occupied by computerised tomography (CT) scanning and magnetic resonance imaging (MRI). Hence, the role of CEUS may be of interest to all diagnostic imaging practitioners. Here we summarise the mode of action and use of CEUS, and its role within a range of applications. The potential risks of CEUS are compared to other contrast-enhanced imaging techniques. The benefits of CEUS and its implications for diagnostic imaging practice are also covered.

  2. A fast mass spring model solver for high-resolution elastic objects

    Science.gov (United States)

    Zheng, Mianlun; Yuan, Zhiyong; Zhu, Weixu; Zhang, Guian

    2017-03-01

    Real-time simulation of elastic objects is of great importance for computer graphics and virtual reality applications. The fast mass spring model solver can achieve visually realistic simulation in an efficient way. Unfortunately, this method suffers from resolution limitations and lack of mechanical realism for a surface geometry model, which greatly restricts its application. To tackle these problems, in this paper we propose a fast mass spring model solver for high-resolution elastic objects. First, we project the complex surface geometry model into a set of uniform grid cells as cages through *cages mean value coordinate method to reflect its internal structure and mechanics properties. Then, we replace the original Cholesky decomposition method in the fast mass spring model solver with a conjugate gradient method, which can make the fast mass spring model solver more efficient for detailed surface geometry models. Finally, we propose a graphics processing unit accelerated parallel algorithm for the conjugate gradient method. Experimental results show that our method can realize efficient deformation simulation of 3D elastic objects with visual reality and physical fidelity, which has a great potential for applications in computer animation.

  3. High-resolution electron microscopy and its applications.

    Science.gov (United States)

    Li, F H

    1987-12-01

    A review of research on high-resolution electron microscopy (HREM) carried out at the Institute of Physics, the Chinese Academy of Sciences, is presented. Apart from the direct observation of crystal and quasicrystal defects for some alloys, oxides, minerals, etc., and the structure determination for some minute crystals, an approximate image-contrast theory named pseudo-weak-phase object approximation (PWPOA), which shows the image contrast change with crystal thickness, is described. Within the framework of PWPOA, the image contrast of lithium ions in the crystal of R-Li2Ti3O7 has been observed. The usefulness of diffraction analysis techniques such as the direct method and Patterson method in HREM is discussed. Image deconvolution and resolution enhancement for weak-phase objects by use of the direct method are illustrated. In addition, preliminary results of image restoration for thick crystals are given.

  4. Single-energy non-contrast hepatic steatosis criteria applied to virtual non-contrast images: is it still highly specific and positively predictive?

    Science.gov (United States)

    Haji-Momenian, S; Parkinson, W; Khati, N; Brindle, K; Earls, J; Zeman, R K

    2018-06-01

    To determine the sensitivity, specificity, and predictive values of single-energy non-contrast hepatic steatosis criteria on dual-energy virtual non-contrast (VNC) images. Forty-eight computed tomography (CT) examinations, which included single-energy non-contrast (TNC) and contrast-enhanced dual-energy CT angiography (CTA) of the abdomen, were enrolled. VNC images were reconstructed from the CTA. Region of interest (ROI) attenuations were measured in the right and left hepatic lobes, spleen, and aorta on TNC and VNC images. The right and left hepatic lobes were treated as separate samples. Steatosis was diagnosed based on TNC liver attenuation of ≤40 HU or liver attenuation index (LAI) of ≤-10 HU, which are extremely specific and predictive for moderate to severe steatosis. The sensitivity, specificity, and predictive values of VNC images for steatosis were calculated. VNC-TNC deviations were correlated with aortic enhancement and patient water equivalent diameter (PWED). Thirty-two liver ROIs met steatosis criteria based on TNC attenuation; VNC attenuation had sensitivity, specificity, and a positive predictive value of 66.7%, 100%, and 100%, respectively. Twenty-one liver ROIs met steatosis criteria based on TNC LAI. VNC LAI had sensitivity, specificity, and positive predictive values of 61.9%, 90.7%, and 65%, respectively. Hepatic and splenic VNC-TNC deviations did not correlate with one another (R 2 =0.08), aortic enhancement (R 2 predictive for moderate to severe steatosis on VNC reconstructions from the arterial phase. Hepatic attenuation performs better than LAI criteria. VNC deviations are independent of aortic enhancement and PWED. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Identification of rounded atelectasis in workers exposed to asbestos by contrast helical computed tomography

    International Nuclear Information System (INIS)

    Terra-Filho, M.; Kavakama, J.; Bagatin, E.; Capelozzi, V.L.; Nery, L.E.; Tavares, R.

    2003-01-01

    Rounded atelectasis (RA) is a benign and unusual form of sub pleural lung collapse that has been described mostly in asbestos-exposed workers. This form of atelectasis manifests as a lung nodule and can be confused with bronchogenic carcinoma upon conventional radiologic examination. The objective of the present study was to evaluate the variation in contrast uptake in computed tomography for the identification of asbestos-related RA in Brazil. Between January 1998 and December 2000, high-resolution computed tomography (HRCT) was performed in 1658 asbestos-exposed workers. The diagnosis was made in nine patients based on a history of prior asbestos exposure, the presence of characteristic (HRCT) findings and lesions unchanged in size over 2 years or more. In three of them the diagnosis was confirmed during surgery. The dynamic contrast enhancement study was modified to evaluate nodules and pulmonary masses. All nine patients with R A received iodide contrast according to weight. The average enhancement after iodide contrast was infused, reported as Hounsfield units (HU), increased from 62.5±9.7 to 125.4±20.7 (P < 0.05), with a mean enhancement of 62.5±19.7 (range 40 to 89) and with a uniform dense opacification. In conclusion, in this study all patients with R A showed contrast enhancement with uniform dense opacification. The main clinical implication of this finding is that this procedure does not permit differentiation between RA and malignant pulmonary neoplasm. (author)

  6. The second-order differential phase contrast and its retrieval for imaging with x-ray Talbot interferometry

    International Nuclear Information System (INIS)

    Yang Yi; Tang Xiangyang

    2012-01-01

    Purpose: The x-ray differential phase contrast imaging implemented with the Talbot interferometry has recently been reported to be capable of providing tomographic images corresponding to attenuation-contrast, phase-contrast, and dark-field contrast, simultaneously, from a single set of projection data. The authors believe that, along with small-angle x-ray scattering, the second-order phase derivative Φ ″ s (x) plays a role in the generation of dark-field contrast. In this paper, the authors derive the analytic formulae to characterize the contribution made by the second-order phase derivative to the dark-field contrast (namely, second-order differential phase contrast) and validate them via computer simulation study. By proposing a practical retrieval method, the authors investigate the potential of second-order differential phase contrast imaging for extensive applications. Methods: The theoretical derivation starts at assuming that the refractive index decrement of an object can be decomposed into δ=δ s +δ f , where δ f corresponds to the object's fine structures and manifests itself in the dark-field contrast via small-angle scattering. Based on the paraxial Fresnel-Kirchhoff theory, the analytic formulae to characterize the contribution made by δ s , which corresponds to the object's smooth structures, to the dark-field contrast are derived. Through computer simulation with specially designed numerical phantoms, an x-ray differential phase contrast imaging system implemented with the Talbot interferometry is utilized to evaluate and validate the derived formulae. The same imaging system is also utilized to evaluate and verify the capability of the proposed method to retrieve the second-order differential phase contrast for imaging, as well as its robustness over the dimension of detector cell and the number of steps in grating shifting. Results: Both analytic formulae and computer simulations show that, in addition to small-angle scattering, the

  7. Symbolic comparisons of objects on color attributes.

    Science.gov (United States)

    Paivio, A; te Linde, J

    1980-11-01

    Symbolic comparisons of object brightness and color were investigated in two experiments using words and outline drawings as stimuli. Both experiments yielded orderly symbolic distance effects. Contrary to prediction, no reliable picture advantages emerged. For color comparison, individual differences in word fluency and color memory predicted decision time with word stimuli. These results contrast sharply with those of previous comparison studies involving concrete dimensions. The results are discussed in terms of dual-coding theory and the role of verbal mechanisms in memory for object color.

  8. Does area V3A predict positions of moving objects?

    Directory of Open Access Journals (Sweden)

    Gerrit W Maus

    2010-11-01

    Full Text Available A gradually fading moving object is perceived to disappear at positions beyond its luminance detection threshold, whereas abrupt offsets are usually localised accurately. What role does retinotopic activity in visual cortex play in this motion-induced mislocalization of the endpoint of fading objects? Using functional magnetic resonance imaging (fMRI, we localised regions of interest (ROIs in retinotopic maps abutting the trajectory endpoint of a bar moving either towards or away from this position while gradually decreasing or increasing in luminance. Area V3A showed predictive activity, with stronger fMRI responses for motion towards versus away from the ROI. This effect was independent of the change in luminance. In Area V1 we found higher activity for high-contrast onsets and offsets near the ROI, but no significant differences between motion directions. We suggest that perceived final positions of moving objects are based on an interplay of predictive position representations in higher motion-sensitive retinotopic areas and offset transients in primary visual cortex.

  9. Contrast configuration influences grouping in apparent motion.

    Science.gov (United States)

    Ma-Wyatt, Anna; Clifford, Colin W G; Wenderoth, Peter

    2005-01-01

    We investigated whether the same principles that influence grouping in static displays also influence grouping in apparent motion. Using the Ternus display, we found that the proportion of group motion reports was influenced by changes in contrast configuration. Subjects made judgments of completion of these same configurations in a static display. Generally, contrast configurations that induced a high proportion of group motion responses were judged as more 'complete' in static displays. Using a stereo display, we then tested whether stereo information and T-junction information were critical for this increase in group motion. Perceived grouping was consistently higher for same contrast polarity configurations than for opposite contrast polarity configurations, regardless of the presence of stereo information or explicit T-junctions. Thus, while grouping in static and moving displays showed a similar dependence on contrast configuration, motion grouping showed little dependence on stereo or T-junction information.

  10. [The influence of printing technology conditions on the accuracy and reproducibility of printed contrast panels for assessing contrast sensitivity].

    Science.gov (United States)

    Raabe, T; Jung, U; Wilhelm, H

    2014-08-01

    Contrast studies can provide important knowledge for treatment decisions before surgery or for assessing the driving ability of professional drivers. Accordingly, high demands are placed on contrast panels to obtain reliable and reproducible results. The aim of the study is to find out if the contrast panels on the market meet the requirements. On the basis of measurement evaluation and schematic presentations potential sources of error can be identified. These sources of error may have a decisive influence on the assessment of contrast vision. Far-reaching analyses have shown that three parameters can have a significant influence on the accuracy and reproducibility of printed contrast panels. This holds for certain properties of the printing substrate, the type of representation of display element, and the choice of the colourant. Only the correct interaction between the substrate and the print colour effects an angle-independent contrast. A matt substrate is necessary, which has a low difference to the printed contrast element in respect of glow, so that possible angle differences have no influence on the contrast assessment. The contrast elements of a contrast panel vary in brightness. Conventional methods for typographical representation of different brightnesses use the method of screening. This causes undesirable edges, which weaken in particular the lower-contrast elements unintentionally. Use of special colours can avoid this effect. In the visible wavelength range the studied contrast elements have an irregular absorption behaviour. Because of differences between the lighting surroundings, this can lead to a differentiated stimulation of cones in practice. Appropriate colourants have a constant absorption behaviour. To get representative results of contrast studies the production of contrast panels needs more knowledge about the interaction between paper and colour than is typically required for print products. On the basis of a prototype optimisation

  11. High spectral resolution observations of the H2 2.12 micron line in Herbig-Haro objects

    International Nuclear Information System (INIS)

    Zinnecker, H.; Mundt, R.; Geballe, T.R.; Zealey, W.J.

    1989-01-01

    High-spectral-resolution Fabry-Perot observations of the H 2 2.12-micron line emissions of several Herbig-Haro (HH) objects are discussed. It is shown that H 2 emission by the shock heating of external molecular gas in the wings of the bow shock associated with the working surface of a high-velocity jet may occur for HH objects associated with the jet's end. The shock heating of external molecular gas entrained in the flow by internal shocks occurring in the jet itself and/or in its boundary layer may be the H 2 emission mechanism for HH objects observed along the flow axis. 59 refs

  12. Pharmacodynamics and tolerance of X-ray contrast media

    International Nuclear Information System (INIS)

    Schmiedel, E.

    1987-01-01

    The improved tolerance of nonionic contrast media compared with conventional contrast media is mainly due to their lower osmolality and reduced allergoid potential. Tolerance advantages that have been definitely proven are, for example, low-pain contrast medium injection and superior systemic tolerance; side effects of an allergic pattern occur less often. Animals experiments have established that nonionic contrast media exercise a comparatively lower influence on the cardiovascular system. The haemodynamics of pulmonary circulation are less adversely affected on intravenous bolus injection. Reduced potential risk is to be expected especially in cardiac and bronchopulmonary high-risk patients. The reduced nephrotoxicity of nonionic contrast media was definitely established by clinical studies. Further systematic studies will however be required to provide an answer to the question whether this also entails a reduction in the incidence of renal failures induced by contrast media. (orig.) [de

  13. Trusted Objects

    International Nuclear Information System (INIS)

    CAMPBELL, PHILIP L.; PIERSON, LYNDON G.; WITZKE, EDWARD L.

    1999-01-01

    In the world of computers a trusted object is a collection of possibly-sensitive data and programs that can be allowed to reside and execute on a computer, even on an adversary's machine. Beyond the scope of one computer we believe that network-based agents in high-consequence and highly reliable applications will depend on this approach, and that the basis for such objects is what we call ''faithful execution.''

  14. Improving human object recognition performance using video enhancement techniques

    Science.gov (United States)

    Whitman, Lucy S.; Lewis, Colin; Oakley, John P.

    2004-12-01

    Atmospheric scattering causes significant degradation in the quality of video images, particularly when imaging over long distances. The principle problem is the reduction in contrast due to scattered light. It is known that when the scattering particles are not too large compared with the imaging wavelength (i.e. Mie scattering) then high spatial resolution information may be contained within a low-contrast image. Unfortunately this information is not easily perceived by a human observer, particularly when using a standard video monitor. A secondary problem is the difficulty of achieving a sharp focus since automatic focus techniques tend to fail in such conditions. Recently several commercial colour video processing systems have become available. These systems use various techniques to improve image quality in low contrast conditions whilst retaining colour content. These systems produce improvements in subjective image quality in some situations, particularly in conditions of haze and light fog. There is also some evidence that video enhancement leads to improved ATR performance when used as a pre-processing stage. Psychological literature indicates that low contrast levels generally lead to a reduction in the performance of human observers in carrying out simple visual tasks. The aim of this paper is to present the results of an empirical study on object recognition in adverse viewing conditions. The chosen visual task was vehicle number plate recognition at long ranges (500 m and beyond). Two different commercial video enhancement systems are evaluated using the same protocol. The results show an increase in effective range with some differences between the different enhancement systems.

  15. An exploratory study of contrast agents for soft tissue visualization by means of high resolution X-ray computed tomography imaging.

    Science.gov (United States)

    Pauwels, E; Van Loo, D; Cornillie, P; Brabant, L; Van Hoorebeke, L

    2013-04-01

    High resolution X-ray computed tomography (CT), or microCT, is a promising and already widely used technique in various scientific fields. Also for histological purposes it has great potential. Although microCT has proven to be a valuable technique for the imaging of bone structures, the visualization of soft tissue structures is still an important challenge due to their low inherent X-ray contrast. One way to achieve contrast enhancement is to make use of contrast agents. However, contrary to light and electron microscopy, knowledge about contrast agents and staining procedures is limited for X-ray CT. The purpose of this paper is to identify useful X-ray contrast agents for soft tissue visualization, which can be applied in a simple way and are also suited for samples larger than (1 cm)(3) . And 28 chemical substances have been investigated. All chemicals were applied in the form of concentrated aqueous solutions in which the samples were immersed. First, strips of green Bacon were stained to evaluate contrast enhancement between muscle and adipose tissue. Furthermore it was also tested whether the contrast agents remained fixed in the tissue after staining by re-immersing them in water. Based on the results, 12 contrast agents were selected for further testing on postmortem mice hind legs, containing a variety of different tissues, including muscle, fat, bone, cartilage and tendons. It was evaluated whether the contrast agents allowed a clearer distinction between the different soft tissue structures present. Finally also penetration depth was measured. And 26 chemicals resulted in contrast enhancement between muscle and adipose tissue in the Bacon strips. Mercury(II)chloride (HgCl2 ), phosphotungstic acid (PTA), phosphomolybdic acid (PMA) and ammonium orthomolybdate ((NH4 )2 MoO4 ) remained fixed after re-immersion in water. The penetration tests showed that potassium iodide (KI) and sodium tungstate can be most efficiently used for large samples of the order

  16. PCA-based approach for subtracting thermal background emission in high-contrast imaging data

    Science.gov (United States)

    Hunziker, S.; Quanz, S. P.; Amara, A.; Meyer, M. R.

    2018-03-01

    Aims.Ground-based observations at thermal infrared wavelengths suffer from large background radiation due to the sky, telescope and warm surfaces in the instrument. This significantly limits the sensitivity of ground-based observations at wavelengths longer than 3 μm. The main purpose of this work is to analyse this background emission in infrared high-contrast imaging data as illustrative of the problem, show how it can be modelled and subtracted and demonstrate that it can improve the detection of faint sources, such as exoplanets. Methods: We used principal component analysis (PCA) to model and subtract the thermal background emission in three archival high-contrast angular differential imaging datasets in the M' and L' filter. We used an M' dataset of β Pic to describe in detail how the algorithm works and explain how it can be applied. The results of the background subtraction are compared to the results from a conventional mean background subtraction scheme applied to the same dataset. Finally, both methods for background subtraction are compared by performing complete data reductions. We analysed the results from the M' dataset of HD 100546 only qualitatively. For the M' band dataset of β Pic and the L' band dataset of HD 169142, which was obtained with an angular groove phase mask vortex vector coronagraph, we also calculated and analysed the achieved signal-to-noise ratio (S/N). Results: We show that applying PCA is an effective way to remove spatially and temporarily varying thermal background emission down to close to the background limit. The procedure also proves to be very successful at reconstructing the background that is hidden behind the point spread function. In the complete data reductions, we find at least qualitative improvements for HD 100546 and HD 169142, however, we fail to find a significant increase in S/N of β Pic b. We discuss these findings and argue that in particular datasets with strongly varying observing conditions or

  17. Stored object knowledge and the production of referring expressions: The case of color typicality

    Directory of Open Access Journals (Sweden)

    Hans eWesterbeek

    2015-07-01

    Full Text Available When speakers describe objects with atypical properties, do they include these properties in their referring expressions, even when that is not strictly required for unique referent identification? Based on previous work, we predict that speakers mention the color of a target object more often when the object is atypically colored, compared to when it is typical. Taking literature from object recognition and visual attention into account, we further hypothesize that this behavior is proportional to the degree to which a color is atypical, and whether color is a highly diagnostic feature in the referred-to object's identity. We investigate these expectations in two language production experiments, in which participants referred to target objects in visual contexts. In Experiment 1, we find a strong effect of color typicality: less typical colors for target objects predict higher proportions of referring expressions that include color. In Experiment 2 we manipulated objects with more complex shapes, for which color is less diagnostic, and we find that the color typicality effect is moderated by color diagnosticity: it is strongest for high-color-diagnostic objects (i.e., objects with a simple shape. These results suggest that the production of atypical color attributes results from a contrast with stored knowledge, an effect which is stronger when color is more central to object identification. Our findings offer evidence for models of reference production that incorporate general object knowledge, in order to be able to capture these effects of typicality on determining the content of referring expressions.

  18. Contrast material-enhanced CT of the abdomen

    International Nuclear Information System (INIS)

    Fishman, E.K.; Kuhlman, J.E.; Garrity, M.; Paris, D.A.

    1988-01-01

    A randomized double-blind comparison of a nonionic contrast agent (Omnipaque) and an ionic contrast agent (Hypaque) was performed to determine any difference between the two agents in the quality and performance of computed body tomography (CT). A total of 40 patient studies were performed on a state-of-the-art CT scanner with similar scanning techniques. The contrast agent was administered intravenously as a rapid infusion in all cases. The image quality of the abdominal CT scans was good to excellent in all cases. There was no difference between the ionic and nonionic agents in terms of study quality. The 20 patients who received nonionic contrast agents had no major or minor reactions. Five of the 20 patients receiving the ionic contrast agent had a total of ten adverse reactions, including nausea and vomiting, nasal congestion, sneezing, and urticaria. The authors conclude that nonionic contrast agents provide high-quality CT scans equal to those provided by ionic agents and also result in fewer reactions and less discomfort

  19. Comparative study of pneumocystography, positive contrast cystography and double contrast cystography in dogs; Estudio comparativo entre la neumocistografia, la cistografia de contraste positivo y la cistografia de doble contraste en perros

    Energy Technology Data Exchange (ETDEWEB)

    Thibaut, J.; Parada, E. [Universidad Austral de Chile, Valdivia (Chile); Vargas, L.; Deppe, R.; Born, R.

    1997-07-01

    In order to compare three radiographic techniques: pneumocystography, positive contrast cystography and double contrast cystography, three series of 24 radiographs each in lateral and ventrodorsal projections were made. Six healthy adult male dogs with weight ranging between 7 and 16 kg were used. Food was withheld for 24 hours and two enemas were made before the series of radiographs were taken. Dogs were anaesthetized with sodium thiopental (20 mg/kg i.v.). The contrast medium was introduced through a urethral catheter. Pneumocystography was performed in the first series introducing air (10 ml/kg) in the bladder. Positive contrast cystography was performed in the second series introducing Hypaque M-60% diluted, contributing 100 mg of iodine per ml (10 ml/kg). In the double contrast cystography Hypaque M-60% diluted (10 ml) was introduced, in concentration of 150 mg of iodine per ml. Then air was introduced (10 ml/kg) through a catheter. Plates were taken in both projections at 1 and 10 minutes for each technique. The radiographic plates of each series were analized comparing the characteristics of radiographic density, outline and size. In neumocystography, positive contrast and double contrast cystography, the radiographic density was predominantly low, high and intermediate, respectively. The radiographic outline was mainly regular for the three techniques. With respect to bladder size, there was a decrease of height and an increase of length and width at 10 minutes. Comparing these three radiographic techniques, it can be concluded that the one that best outlines the bladder mucosa is double contrast. Pneumocystography provides the best image for opaque structures and cystography best shows the position of the urinary bladder [Spanish] Se tomaron 3 series de 24 radiografias cada una, en proyeccion lateral y ventrodorsal. Se trabajo en cada serie con 6 perros machos clinicamente sanos 5 con un peso que vario entre los 7 y 16 kg. Previo a cada serie se efectuo

  20. Sub-GHz-resolution C-band Nyquist-filtering interleaver on a high-index-contrast photonic integrated circuit.

    Science.gov (United States)

    Zhuang, Leimeng; Zhu, Chen; Corcoran, Bill; Burla, Maurizio; Roeloffzen, Chris G H; Leinse, Arne; Schröder, Jochen; Lowery, Arthur J

    2016-03-21

    Modern optical communications rely on high-resolution, high-bandwidth filtering to maximize the data-carrying capacity of fiber-optic networks. Such filtering typically requires high-speed, power-hungry digital processes in the electrical domain. Passive optical filters currently provide high bandwidths with low power consumption, but at the expense of resolution. Here, we present a passive filter chip that functions as an optical Nyquist-filtering interleaver featuring sub-GHz resolution and a near-rectangular passband with 8% roll-off. This performance is highly promising for high-spectral-efficiency Nyquist wavelength division multiplexed (N-WDM) optical super-channels. The chip provides a simple two-ring-resonator-assisted Mach-Zehnder interferometer, which has a sub-cm2 footprint owing to the high-index-contrast Si3N4/SiO2 waveguide, while manifests low wavelength-dependency enabling C-band (> 4 THz) coverage with more than 160 effective free spectral ranges of 25 GHz. This device is anticipated to be a critical building block for spectrally-efficient, chip-scale transceivers and ROADMs for N-WDM super-channels in next-generation optical communication networks.

  1. Contrast enhancement of mail piece images

    Science.gov (United States)

    Shin, Yong-Chul; Sridhar, Ramalingam; Demjanenko, Victor; Palumbo, Paul W.; Hull, Jonathan J.

    1992-08-01

    A New approach to contrast enhancement of mail piece images is presented. The contrast enhancement is used as a preprocessing step in the real-time address block location (RT-ABL) system. The RT-ABL system processes a stream of mail piece images and locates destination address blocks. Most of the mail pieces (classified into letters) show high contrast between background and foreground. As an extreme case, however, the seasonal greeting cards usually use colored envelopes which results in reduced contrast osured by an error rate by using a linear distributed associative memory (DAM). The DAM is trained to recognize the spectra of three classes of images: with high, medium, and low OCR error rates. The DAM is not forced to make a classification every time. It is allowed to reject as unknown a spectrum presented that does not closely resemble any that has been stored in the DAM. The DAM was fairly accurate with noisy images but conservative (i.e., rejected several text images as unknowns) when there was little ground and foreground degradations without affecting the nondegraded images. This approach provides local enhancement which adapts to local features. In order to simplify the computation of A and (sigma) , dynamic programming technique is used. Implementation details, performance, and the results on test images are presented in this paper.

  2. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  3. Color contrasting in radioscopy systems

    International Nuclear Information System (INIS)

    Lopaev, V.P.; Pavlov, S.V.; Nazarenko, V.G.

    1979-01-01

    Transformation principles for achromatic radioscopy control systems to color ones have been considered. Described is the developed ''Gamma 1'' roentgen-TV facility with color contrasting, which is based on the principle of analog conversion of brightness signal to a hue. By means of color channels amplifiers realized are the special amplitude characteristics, permitting in comparison with the common method of analogous transformation to obtain the greater number of hues within the identical range of brightnesses of image under investigation due to introducing purple colors. The investigation of amplitude resolution capability of color contrasting device has shown, that in the case of color contrasting of image the amplitude resolution is 1.7-1.8 time higher than in the case of achromatic one. Defectoscopic sensitivity during the testing of 5-20 mm thick steel products in the process of experimental-production tests turned out to be 1.1-1.3 time higher when using color contrasting of radioscopic image. Realization simplicity, high resolution, noise stability and wide functional possibilities of the facility show the prospects for its using during the quality control of welded joints in products of power engineering

  4. {sup 18}F-FDG PET/contrast enhanced CT in the standard surveillance of high risk colorectal cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Jiménez Londoño, Germán Andrés, E-mail: gjimenez91@yahoo.com [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); García Vicente, Ana María [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Sánchez Pérez, Victoria [Department of Oncology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Jiménez Aragón, Fátima [Department of Radiology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); León Martin, Alberto [Investigation Unit, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Cano Cano, Juana María [Department of Oncology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Domínguez Ferreras, Esther [Department of Radiology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Gómez López, Ober Van [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Espinosa Arranz, Javier [Department of Oncology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Soriano Castrejón, Ángel María [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain)

    2014-12-15

    Highlights: • We assessed the accuracy of FDG-PET/contrast enhanced CT (FDG-PET/ceCT) in the detection of unsuspected recurrence of colorectal cancer. In regard to our knowledge, no previous experience has been reported about the combined acquisition and interpretation of a FDG-PET/ceCT in the surveillance of colorectal cancer. • We designed a prospective study and performed an individual and combined assessment of both techniques (PET and ceCT), in a patient-based analysis and a lesion-based analysis. • The value of PET and ceCT was found to be similar in the detection of unsuspected recurrence of CRC in a patient-based analysis. The most interesting of our result, is that the combined assessment of PET/ceCT improves the accuracy in the lesion-based analysis. - Abstract: Objective: To assess the accuracy of FDG-PET/contrast enhanced CT (FDG-PET/ceCT) in the detection of unsuspected recurrence of colorectal cancer (CRC) in patients with high risk of relapse. Methods: Thirty-three patients (14 females and 19 males, mean age: 62, range: 41–78), with CRC in complete remission, were prospectively included. All patients underwent FDG-PET/ceCT (58 studies). FDG-PET/ceCT was requested in the surveillance setting, and performed following a standardized protocol. A portal venous phase CT scan was performed after the injection of iodinated contrast agent. An individual and combined assessment of both techniques (PET and ceCT) was performed. Concordant and discordant findings of PET, ceCT and FDG-PET/ceCT were compared in a patient-based and a lesion-based analysis. The final diagnosis, recurrence or disease free status (DFS), were established by histopathology or clinical/radiological follow-up of at least 6 months. Results: Seven out of 33 patients had a confirmed recurrence and the rest of patients had a DFS. In a patient-based analysis the sensitivity and specificity of PET, ceCT and PET/ceCT was of 86% and 88%, 86% and 92%, 86% and 85%, respectively. Attending to

  5. Contrast-enhanced spectral mammography (CESM) versus MRI in the high-risk screening setting: patient preferences and attitudes.

    Science.gov (United States)

    Phillips, Jordana; Miller, Matthew M; Mehta, Tejas S; Fein-Zachary, Valerie; Nathanson, Audrey; Hori, Wendy; Monahan-Earley, Rita; Slanetz, Priscilla J

    Our study evaluates patient preferences toward screening CESM versus MRI. As part of a prospective study, high-risk patients had breast MRI and CESM. Patients completed an anonymous survey to evaluate preferences regarding the two modalities. 88% of participants completed the survey. 79% preferred CESM over MRI if the exams had equal sensitivity. 89% would be comfortable receiving contrast as part of an annual screening test. High-risk populations may accept CESM as a screening exam and may prefer it over screening MRI if ongoing trials demonstrate screening CESM to be clinically non-inferior MRI. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Cloud object store for archive storage of high performance computing data using decoupling middleware

    Science.gov (United States)

    Bent, John M.; Faibish, Sorin; Grider, Gary

    2015-06-30

    Cloud object storage is enabled for archived data, such as checkpoints and results, of high performance computing applications using a middleware process. A plurality of archived files, such as checkpoint files and results, generated by a plurality of processes in a parallel computing system are stored by obtaining the plurality of archived files from the parallel computing system; converting the plurality of archived files to objects using a log structured file system middleware process; and providing the objects for storage in a cloud object storage system. The plurality of processes may run, for example, on a plurality of compute nodes. The log structured file system middleware process may be embodied, for example, as a Parallel Log-Structured File System (PLFS). The log structured file system middleware process optionally executes on a burst buffer node.

  7. The Timing of Visual Object Categorization

    Science.gov (United States)

    Mack, Michael L.; Palmeri, Thomas J.

    2011-01-01

    An object can be categorized at different levels of abstraction: as natural or man-made, animal or plant, bird or dog, or as a Northern Cardinal or Pyrrhuloxia. There has been growing interest in understanding how quickly categorizations at different levels are made and how the timing of those perceptual decisions changes with experience. We specifically contrast two perspectives on the timing of object categorization at different levels of abstraction. By one account, the relative timing implies a relative timing of stages of visual processing that are tied to particular levels of object categorization: Fast categorizations are fast because they precede other categorizations within the visual processing hierarchy. By another account, the relative timing reflects when perceptual features are available over time and the quality of perceptual evidence used to drive a perceptual decision process: Fast simply means fast, it does not mean first. Understanding the short-term and long-term temporal dynamics of object categorizations is key to developing computational models of visual object recognition. We briefly review a number of models of object categorization and outline how they explain the timing of visual object categorization at different levels of abstraction. PMID:21811480

  8. The Contrastive Study of Igbo and English Denominal Nouns ...

    African Journals Online (AJOL)

    The teaching of nominalization has not been all smooth for an Igbo second language learner of English language. That is why this study is set to contrast English and Igbo Denominal nouns. The objective is to find out the similarities and differences between the nominalization process in Igbo and that of the English ...

  9. Noise reduction in muon tomography for detecting high density objects

    International Nuclear Information System (INIS)

    Benettoni, M; Checchia, P; Cossutta, L; Furlan, M; Gonella, F; Pegoraro, M; Garola, A Rigoni; Ronchese, P; Vanini, S; Viesti, G; Bettella, G; Bonomi, G; Donzella, A; Subieta, M; Zenoni, A; Calvagno, G; Cortelazzo, G; Zanuttigh, P; Calvini, P; Squarcia, S

    2013-01-01

    The muon tomography technique, based on multiple Coulomb scattering of cosmic ray muons, has been proposed as a tool to detect the presence of high density objects inside closed volumes. In this paper a new and innovative method is presented to handle the density fluctuations (noise) of reconstructed images, a well known problem of this technique. The effectiveness of our method is evaluated using experimental data obtained with a muon tomography prototype located at the Legnaro National Laboratories (LNL) of the Istituto Nazionale di Fisica Nucleare (INFN). The results reported in this paper, obtained with real cosmic ray data, show that with appropriate image filtering and muon momentum classification, the muon tomography technique can detect high density materials, such as lead, albeit surrounded by light or medium density material, in short times. A comparison with algorithms published in literature is also presented

  10. Characterization of intraventricular and intracerebral hematomas in non-contrast CT.

    Science.gov (United States)

    Nowinski, Wieslaw L; Gomolka, Ryszard S; Qian, Guoyu; Gupta, Varsha; Ullman, Natalie L; Hanley, Daniel F

    2014-06-01

    Characterization of hematomas is essential in scan reading, manual delineation, and designing automatic segmentation algorithms. Our purpose is to characterize the distribution of intraventricular (IVH) and intracerebral hematomas (ICH) in NCCT scans, study their relationship to gray matter (GM), and to introduce a new tool for quantitative hematoma delineation. We used 289 serial retrospective scans of 51 patients. Hematomas were manually delineated in a two-stage process. Hematoma contours generated in the first stage were quantified and enhanced in the second stage. Delineation was based on new quantitative rules and hematoma profiling, and assisted by a dedicated tool superimposing quantitative information on scans with 3D hematoma display. The tool provides: density maps (40-85HU), contrast maps (8/15HU), mean horizontal/vertical contrasts for hematoma contours, and hematoma contours below a specified mean contrast (8HU). White matter (WM) and GM were segmented automatically. IVH/ICH on serial NCCT is characterized by 59.0HU mean, 60.0HU median, 11.6HU standard deviation, 23.9HU mean contrast, -0.99HU/day slope, and -0.24 skewness (changing over time from negative to positive). Its 0.1(st)-99.9(th) percentile range corresponds to 25-88HU range. WM and GM are highly correlated (R (2)=0.88; phematoma density distributions is at 55.6±5.8HU with the corresponding GM/hematoma percentiles of 88(th)/40(th). Objective characterization of IVH/ICH and stating the rules quantitatively will aid raters to delineate hematomas more robustly and facilitate designing algorithms for automatic hematoma segmentation. Our two-stage process is general and potentially applicable to delineate other pathologies on various modalities more robustly and quantitatively.

  11. Delineation of wetland areas from high resolution WorldView-2 data by object-based method

    International Nuclear Information System (INIS)

    Hassan, N; Hamid, J R A; Adnan, N A; Jaafar, M

    2014-01-01

    Various classification methods are available that can be used to delineate land cover types. Object-based is one of such methods for delineating the land cover from satellite imageries. This paper focuses on the digital image processing aspects of discriminating wetland areas via object-based method using high resolution satellite multispectral WorldView-2 image data taken over part of Penang Island region. This research is an attempt to improve the wetland area delineation in conjunction with a range of classification techniques which can be applied to satellite data with high spatial and spectral resolution such as World View 2. The intent is to determine a suitable approach to delineate and map these wetland areas more appropriately. There are common parameters to take into account that are pivotal in object-based method which are the spatial resolution and the range of spectral channels of the imaging sensor system. The preliminary results of the study showed object-based analysis is capable of delineating wetland region of interest with an accuracy that is acceptable to the required tolerance for land cover classification

  12. Computerized tomography using high resolution X-ray imaging system with a microfocus source

    International Nuclear Information System (INIS)

    Zaprazny, Z.; Korytar, D.; Konopka, P.; Ac, V.; Bielecki, J.

    2011-01-01

    In recent years there is an effort to image an internal structure of an object by using not only conventional 2D X-ray radiography but also using high resolution 3D tomography which is based on reconstruction of multiple 2D projections at various angular positions of the object. We have previously reported [1] the development and basic parameters of a high resolution x-ray imaging system with a microfocus source. We report the recent progress using this high resolution X-ray laboratory system in this work. These first findings show that our system is particularly suitable for light weight and nonmetallic objects such as biological objects, plastics, wood, paper, etc. where phase contrast helps to increase the visibility of the finest structures of the object. Phase-contrast X-ray Computerized Tomography is of our special interest because it is an emerging imaging technique that can be implemented at third generation synchrotron radiation sources and also in laboratory conditions using a microfocus X-ray tube or beam conditioning optics. (authors)

  13. Prevention of Contrast-Induced Nephropathy in STEMI Patients Undergoing Primary Percutaneous Coronary Intervention

    DEFF Research Database (Denmark)

    Busch, Sarah Victoria Ekeløf; Jensen, Svend Eggert; Rosenberg, Jacob

    2012-01-01

    -acetylcysteine, one study of early and late hydration regimens, one study of recombinant human brain natriuretic peptide and one study comparing a low-osmolar contrast agent with an iso-osmolar contrast agent. Results: Recombinant human brain natriuretic peptide and the regimens of hydration significantly reduced...... the incidence of CIN and administration of N-acetylcysteine in one of the six studies significantly reduced the occurrence of CIN. The iso-osmolar contrast agent was not proven to be superior to the low-osmolar contrast agent in terms of preventing CIN. Conclusion: Preliminary studies are promising but further......Objective: To evaluate the current prophylactic strategies against CIN in patients with STEMI treated by primary percutaneous coronary intervention. Background: Contrast-induced nephropathy (CIN) is the third leading course of acute renal failure and a recognized complication to cardiac...

  14. Fat suppression techniques for obtaining high resolution dynamic contrast enhanced bilateral breast MR images at 7 tesla

    DEFF Research Database (Denmark)

    van der Velden, Tijl A; Schmitz, Alexander M Th; Gilhuijs, Kenneth G A

    2016-01-01

    contained 3D T1-weighted gradient echo images obtained with both WSE fat suppression, multi echo Dixon fat suppression, and without fat suppression. Images were acquired at a (0.8mm)(3) or (0.7mm)(3) isotropic resolution with equal field of view and optimized such to obtain a maximal SNR. Image quality...... was scored qualitatively on overall image quality, sharpness of anatomical details, presence of artefacts, inhomogeneous fat suppression and the presence of water-fat shift. A quantitative scoring was obtained from the signal to noise ratio and contrast to noise ratio. RESULTS: WSE scored significantly...... better in terms of overall image quality and the absence of artefacts. No significant difference in contrast to noise ratio was found between the two fat suppression methods. CONCLUSION: When maximizing temporal and spatial resolution of high resolution DCE MRI of the breast, water selective excitation...

  15. Comparison of neutral and positive enteral contrast media for MDCT enteroclysis

    International Nuclear Information System (INIS)

    Aiyappan, Senthil Kumar; Kalra, Naveen; Sandhu, Manavjit Singh; Kochhar, Rakesh; Wig, Jai Dev; Khandelwal, Niranjan

    2012-01-01

    Objective: To compare neutral and positive enteral contrast media for MDCT enteroclysis (MDCTE) in various small bowel diseases. Materials and methods: 40 patients with suspicion of small bowel diseases were divided randomly into two equal groups. In one group, water was used as neutral enteral contrast and in other group, 2% water soluble iodinated contrast was used as positive enteral contrast. All MDCTE were done on a 16-slice multidetector row CT unit. The findings of MDCTE were compared with the standards of reference. Results: There were 12 cases of abdominal tuberculosis (30%), 5 cases of bowel masses (12%), 4 cases of Crohn's disease (10%), 3 cases of small bowel adhesions (7%), 2 cases of midgut volvulus (5%), 2 cases of segmental enteritis (5%) and 12 of all cases (30%) were normal. There was no statistically significant difference between neutral and positive enteral contrast with regards to bowel distention, contrast reflux and evaluation of duodenum. Abnormal bowel wall enhancement was appreciated only with use of neutral enteral contrast (n = 12). Evaluation of ileocaecal junction was possible in all 20 patients (100%) with positive enteral contrast but in only 17 patients (85%) with neutral enteral contrast. Overall sensitivity and specificity of MDCTE with use of neutral contrast medium (100 and 88% respectively) was greater for evaluation of small bowel diseases, when compared to MDCTE using positive enteral contrast medium (92.8 and 83.3% respectively). Conclusions: Water is a good enteral contrast medium for MDCT enteroclysis examination and allows better evaluation of abnormal bowel wall enhancement. Ileocaecal junction evaluation is better with positive enteral contrast medium.

  16. High incidence of nephropathy in neurosurgical patients after intra-arterial administration of low-osmolar and iso-osmolar contrast media.

    Science.gov (United States)

    Serafin, Zbigniew; Karolkiewicz, Maciej; Gruszka, Marzena; Strózecki, Pawel; Lasek, Wladyslaw; Odrowaz-Sypniewska, Grazyna; Manitius, Jacek; Beuth, Wojciech

    2011-05-01

    Percutaneous endovascular examinations and interventions require significant amounts of iodinated contrast media (CM) and have been reported to be complicated by an increased incidence of post-contrast nephropathy. To evaluate renal function, the incidence of post-contrast nephropathy, and risk factors after interventional procedures in neurosurgical patients after intra-arterial administration of a low-osmolar contrast medium (LOCM) versus an iso-osmolar contrast medium (IOCM). This single-center, prospective, randomized, double-blinded study included 92 patients in its final analysis (mean age 49.6 ± 12.6 years, 29.3% men, mean eGFR 97.8 ± 26.3 mL/min/1.73 m(2)). LOCM was used in 48 patients (52.2%) and IOCM in 44 patients (47.8%). The patients were given an average of 151.2 ± 52.1 mL of contrast medium intra-arterially. Serum creatinine (SCr), urinary N-acetyl-β-glucosaminidase (NAG) excretion, and creatinine clearance (CCr) were measured at baseline, and on days 1 and 3 after the procedure. Baseline risk factors, renal functional parameters, and average CM doses were not statistically different between the two groups. SCr, NAG, and CCr values did not differ significantly between the LOCM and IOCM groups on days 1 and 3 after CM administration. Nephropathy developed in 21 cases (22.8%): 13 (27.1%) after LOCM use and 8 (18.2%) after IOCM; (P = NS). The only significant risk factors of CIN were the diabetes (P = 0.0466) and atherosclerosis (P = 0.0498). We found a high incidence of nephropathy in neurosurgical patients after intra-arterial CM administration. The renal function values and incidence of nephropathy following LOCM administration were not statistically different from those following IOCM administration.

  17. Modularity-like objective function in annotated networks

    Science.gov (United States)

    Xie, Jia-Rong; Wang, Bing-Hong

    2017-12-01

    We ascertain the modularity-like objective function whose optimization is equivalent to the maximum likelihood in annotated networks. We demonstrate that the modularity-like objective function is a linear combination of modularity and conditional entropy. In contrast with statistical inference methods, in our method, the influence of the metadata is adjustable; when its influence is strong enough, the metadata can be recovered. Conversely, when it is weak, the detection may correspond to another partition. Between the two, there is a transition. This paper provides a concept for expanding the scope of modularity methods.

  18. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me....../min/1.73 m (2) is CIN risk threshold for intravenous contrast medium. • Hydration with either saline or sodium bicarbonate reduces CIN incidence. • Patients with eGFR = 60 ml/min/1.73 m (2) receiving contrast medium can continue metformin normally....

  19. Electrical Capacitance Volume Tomography with High-Contrast Dielectrics

    Science.gov (United States)

    Nurge, Mark

    2010-01-01

    The Electrical Capacitance Volume Tomography (ECVT) system has been designed to complement the tools created to sense the presence of water in nonconductive spacecraft materials, by helping to not only find the approximate location of moisture but also its quantity and depth. The ECVT system has been created for use with a new image reconstruction algorithm capable of imaging high-contrast dielectric distributions. Rather than relying solely on mutual capacitance readings as is done in traditional electrical capacitance tomography applications, this method reconstructs high-resolution images using only the self-capacitance measurements. The image reconstruction method assumes that the material under inspection consists of a binary dielectric distribution, with either a high relative dielectric value representing the water or a low dielectric value for the background material. By constraining the unknown dielectric material to one of two values, the inverse math problem that must be solved to generate the image is no longer ill-determined. The image resolution becomes limited only by the accuracy and resolution of the measurement circuitry. Images were reconstructed using this method with both synthetic and real data acquired using an aluminum structure inserted at different positions within the sensing region. The cuboid geometry of the system has two parallel planes of 16 conductors arranged in a 4 4 pattern. The electrode geometry consists of parallel planes of copper conductors, connected through custom-built switch electronics, to a commercially available capacitance to digital converter. The figure shows two 4 4 arrays of electrodes milled from square sections of copper-clad circuit-board material and mounted on two pieces of glass-filled plastic backing, which were cut to approximately square shapes, 10 cm on a side. Each electrode is placed on 2.0-cm centers. The parallel arrays were mounted with the electrode arrays approximately 3 cm apart. The open ends

  20. Utilizing generalized autocalibrating partial parallel acquisition (GRAPPA) to achieve high-resolution contrast-enhanced MR angiography of hepatic artery: Initial experience in orthotopic liver transplantation candidates

    International Nuclear Information System (INIS)

    Xu Pengju; Yan Fuhua; Wang Jianhua; Lin Jiang; Fan Jia

    2007-01-01

    Objective: To evaluate feasibility of using GRAPPA to acquire high-resolution 3D contrast-enhanced MR angiography (CE-MRA) of hepatic artery and value of GRAPPA for displaying vessels anatomy. Materials and methods: High-resolution CE-MRA using GRAPPA was performed in 67 orthotopic liver transplantation recipient candidates. Signal intensity (SI) and relative SI, i.e., Cv-ro (vessel-to-liver contrast) of the aorta and the hepatic common artery (HCA), were measured. The SI and the relative SI were compared and analyzed using T-test. For purpose of qualitative evaluation, the vessel visualization quality and the order of depicted hepatic artery branches were evaluated by two radiologists independently and assessed by weighted kappa analysis. The depiction of hepatic arterial anatomy and variations was evaluated, and results were correlated with the findings in surgery. Results: The mean SI values were 283.29 ± 65.07 (mean ± S.D.) for aorta and 283.16 ± 64.07 for HCA, respectively. The mean relative SI values were 0.698 ± 0.09 for aorta and 0.696 ± 0.09 for HCA, respectively. Homogeneous enhancement between aorta and HCA was confirmed by statistically insignificant differences (p-values were 0.89 for mean SI values and 0.12 for mean relative SI values, respectively). The average score for vessel visualization ranged from good to excellent for different artery segments. Overall interobserver agreement in the visualization of different artery segments was excellent (kappa value > 0.80). The distal intrahepatic segmental arteries were well delineated for majority of patients with excellent interobserver agreement. Normal hepatic arterial anatomy was correctly demonstrated in 53 patients, and arterial anomalies were accurately detected on high-resolution MRA image of all 14 patients. Conclusion: High-resolution hepatic artery MRA acquired using GRAPPA in a reproducible manner excellently depicts and delineates small vessels and can be routinely used for evaluating