WorldWideScience

Sample records for high clearance rates

  1. Faking giants: the evolution of high prey clearance rates in jellyfishes.

    Science.gov (United States)

    Acuña, José Luis; López-Urrutia, Ángel; Colin, Sean

    2011-09-16

    Jellyfishes have functionally replaced several overexploited commercial stocks of planktivorous fishes. This is paradoxical, because they use a primitive prey capture mechanism requiring direct contact with the prey, whereas fishes use more efficient visual detection. We have compiled published data to show that, in spite of their primitive life-style, jellyfishes exhibit similar instantaneous prey clearance and respiration rates as their fish competitors and similar potential for growth and reproduction. To achieve this production, they have evolved large, water-laden bodies that increase prey contact rates. Although larger bodies are less efficient for swimming, optimization analysis reveals that large collectors are advantageous if they move through the water sufficiently slowly.

  2. High rate of hepatitis C virus (HCV) recurrence in HIV-infected individuals with spontaneous HCV RNA clearance

    DEFF Research Database (Denmark)

    Peters, L; Mocroft, A; Soriano, V

    2014-01-01

    OBJECTIVES: Following resolution of hepatitis C virus (HCV) infection, recurrence has been shown to occur in some persons with repeated exposure to HCV. We aimed to investigate the rate and factors associated with HCV RNA recurrence among HIV-1-infected patients with prior spontaneous HCV RNA...... clearance in the EuroSIDA cohort. METHODS: All HIV-infected patients with documented prior spontaneous HCV clearance, and at least one subsequently collected plasma sample, were examined. The last sample was tested for HCV RNA and those with HCV RNA ≥ 615 IU/mL were defined as having HCV recurrence...

  3. Development of means to augment peritoneal urea clearances: the synergistic effects of combining high dialysate temperature and high dialysate flow rates with dextrose and nitroprusside.

    Science.gov (United States)

    De Santo, N G; Capodicasa, G; Capasso, G; Giordano, C

    1981-11-01

    By combining: a) nitroprusside (4.5 mg/L); b) dextrose concentration of 42.5 gm/L; c) dialysate temperature of 42 degrees C and d) dialysate flow rates of 3.5 L/hour in seven uremic subjects on CAPD, it was possible to increase peritoneal urea clearance up to 35.6 +/- 3.8 ml/min/1.73 m2 (range 30.3 to 42.2). This effect in six out of seven cases was associated with a fall in blood pressure and an increase in heart rate. This study is the first which deals with a combination of these factors and demonstrates that this approach is easy to handle, does not require the use of mechanical devices, and is available at any bedside.

  4. Dependence between temperature and clearance rate of Balanion comatum Wulff

    Directory of Open Access Journals (Sweden)

    Krzysztof Rychert

    2011-06-01

    Full Text Available The dependence between temperature and clearance rate of the ciliate Balanion comatum Wulff 1919 was assessed in the coastal zone of the southern Baltic Sea. Five in situ experiments were carried out with the use of wheat starch as a surrogate of food particles. The clearance rate rose from 1.4 to 7.0 µl cell-1 h-1 with a temperature rise from 8 to 19°C. B. comatum preferred particles of size 1.9-4.4 µm, and the clearance rates calculated for the preferred particles were consistently higher than those measured for the whole range of particles ingested (Wilcoxon's signed rank test, p = 0.04. The exponential dependence between temperature and clearance rates for preferred particles was statistically significant (R2 = 0.86, p = 0.02 and enabled the Q10 coefficient to be calculated. This amounted to 2.9 and lay within the range of typical values. The linear dependence (also drawn for preferred particles demonstrated a higher significance (R2 = 0.91, p = 0.02, indicating the linear dynamics of the process.

  5. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi [St. Mary' s Hospital, Catholic Medical College, Seoul (Korea, Republic of)

    1970-09-15

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ({sup 198}Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  6. Postprandial chylomicron clearance rate in late teenagers with diabetes mellitus type 1

    NARCIS (Netherlands)

    van Waarde, WM; Odink, RJ; Rouwe, C; Stellaard, F; Westers, M; Vonk, RJ; Sauer, PJJ; Verkade, HJ

    2001-01-01

    A delayed chylomicron (CM) clearance rate, a known risk factor for atherosclerosis, has been described in adults with diabetes type I (DMI). We determined the CM clearance rate in late teenagers with DM1, and the relationship between CM clearance rate and elevated plasma lipid concentrations in DMI

  7. Hepatectomy Based on Future Liver Remnant Plasma Clearance Rate of Indocyanine Green

    Directory of Open Access Journals (Sweden)

    Yuichiro Uchida

    2016-01-01

    Full Text Available Background. Hepatectomy, an important treatment modality for liver malignancies, has high perioperative morbidity and mortality rates. Safe, comprehensive criteria for selecting patients for hepatectomy are needed. Since June 2011, we have used a cut-off value of ≧ 0.05 for future liver remnant plasma clearance rate of indocyanine green as a criterion for hepatectomy. The aim of this study was to verify the validity of this criterion. Methods. From June 2011 to December 2015, 212 hepatectomies were performed in Tenri Yorozu Hospital. Of these 212 patients, 107 who underwent preoperative computed tomography imaging volumetry, indocyanine green clearance test, and hepatectomy (excluding partial resection or enucleation were retrospectively analyzed. Results. There was no postoperative mortality. Posthepatectomy liver failure occurred in 59 patients (55.1% (International Study Group of Liver Surgery Grade A: 43 cases (40.2%, Grade B: 16 cases (15.0%, and Grade C: no cases. Operative morbidity greater than Clavien-Dindo Grade 3 occurred in 23 patients (21.5%. A low future liver remnant plasma clearance rate of indocyanine green was a good predictor for Grade B cases (area under curve = 0.804; 95% confidence interval, 0.712–0.895. Conclusion. Liver remnant plasma clearance rate of indocyanine green is a valid criterion for hepatectomy.

  8. Influence of different hematoma clearance rates on patients with hypertensive intracerebral hemorrhage

    Institute of Scientific and Technical Information of China (English)

    Cheng Zhong; Jing-Zhu Shi; Yu Liu; Tao Ou; Guo-Jing Liu; Bin Wang

    2016-01-01

    Objective:To evaluate the influence of different hematoma clearance rates patients with hypertensive intracerebral hemorrhage.Methods: A total of 94 cases with hypertensive intracerebral hemorrhage treated with operation from June 2012 to June 2015 were selected. According to theirhematoma clearance rates, they were divided into groups A (50%-70%, 28 cases), B (70%-90%,48 cases) and C (90%, 18 cases). The recovery and perioperative levels of serum neuron-specific enolase (NSE) and soluble S-100 protein of the three groups were compared.Results: The perioperative mortality and the rates of postoperative rebleeding, intracranial infection and other complications of the three groups showed no statistical significant difference (P>0.05). With the increase of the hematoma clearance rate, the drainage tube removal time and hematoma complete absorption time reduced significantly (P<0.05). In the groups B and C, the grade levels of ADL in postoperative 3 months were significantly superior to those in the group A (P<0.05). The levels of serum NSE and S-100 in the three groups increased in the initial stage and then declined after surgery. In the group B and C, the serum levels of NSE and S-100 were significantly higher than those in the group A on the 7th day after surgery (P<0.05). With the increase of the hematoma clearance rate, the serum levels of NSE and S-100 were significantly reduced on the 14th day after surgery (P<0.05). Conclusions:High level of hematoma clearance rate can help to increase the operation efficacy and prognosis of patients with hypertensive intracerebral hemorrhage.

  9. Rate of clearance of intrathecal iopamidol in the dog.

    Science.gov (United States)

    Wilcox, J; Evill, C A; Sage, M R

    1986-01-01

    The incidence of post-myelographic side-effects has been significantly reduced since the advent of the new generation of water-soluble, non-ionic, contrast media (CM). One of these CM, iopamidol, has recently been released for clinical intrathecal use in Australia. Clinical evaluations have shown iopamidol to give excellent diagnostic results. However, many adverse side-effects have been cited in the literature. Reactions to iopamidol following myelography are thought to be due to the lack of a physiologic barrier between the extracellular fluid of the brain parenchyma and the CSF, thereby allowing CM to penetrate the brain parenchyma tissue, following subarachnoid injection. This study investigates the rate of clearance of intrathecal iopamidol from the brain in dogs by performing coronal CT scans at intervals over a 48 h, post-injection period. Analysis of similar regions of interest (ROI) for each time period indicate that iopamidol can be detected in canine brains for at least 48 h following intrathecal injection (P less than 0.05). Furthermore, the disappearance of iopamidol from the brain parenchyma is approximately logarithmic in form, with a half-life of approximately 22 h.

  10. Mannitol clearance for the determination of glomerular filtration rate-a validation against clearance of (51) Cr-EDTA.

    Science.gov (United States)

    Kiss, Katalin; Molnár, Miklós; Söndergaard, Sören; Molnár, Gyula; Ricksten, Sven-Erik

    2016-06-03

    We studied the agreement between plasma clearance of mannitol and the reference method, plasma clearance of (51) Cr-EDTA in outpatients with normal to moderately impaired renal function. Forty-one patients with a serum creatinine clearance was measured with the standard bolus injection technique and glomerular filtration rate (GFR) was calculated by the single-sample method described by Jacobsson. Mannitol, 0·25 g kg(-1) body weight (150 mg ml(-1) ), was infused for 4-14 min and blood samples taken at 1-, 2-, 3- and 4-h (n = 24) or 2-, 3-, 3·5- and 4-h after infusion (n = 17). Mannitol in serum was measured by an enzymatic method. Plasma clearance for mannitol and its apparent volume of distribution (Vd) were calculated according to Brøchner-Mortensen. Mean plasma clearance (±SD) for (51) Cr-EDTA was 59·7 ± 18·8 ml min(-1) . The mean plasma clearance for mannitol ranged between 57·0 ± 20·1 and 61·1 ± 16·7 ml min(-1) and Vd was 21·3 ± 6·2% per kg b.w. The between-method bias ranged between -0·23 and 2·73 ml min(-1) , the percentage error between 26·7 and 39·5% and the limits of agreement between -14·3/17·2 and -25·3/19·9 ml min(-1) . The best agreement was seen when three- or four-sample measurements of plasma mannitol were obtained and when sampling started 60 min after injection. Furthermore, accuracy of plasma clearance determinations was 88-96% (P30) and 41-63% (P10) and was highest when three- or four-sample measurements of plasma mannitol were obtained, including the first hour after the bolus dose. We conclude that there is a good agreement between plasma clearances of mannitol and (51) Cr-EDTA for the assessment of GFR.

  11. Design and experiment of self-propelled high-ground- clearance spreader for paddy variable-rate fertilization%水田高地隙自走式变量撒肥机设计与试验

    Institute of Scientific and Technical Information of China (English)

    陈书法; 张石平; 孙星钊; 李耀明

    2012-01-01

    为解决现有水田撒肥机械地隙低、撒肥量调节技术落后、工作效率低等问题,设计了一种水田高地隙自走式变量撒肥机,介绍了整机结构与工作原理,研究设计了高地隙专用底盘、撒肥盘及排肥口调节装置,并确定了关键结构和参数,对以AT89C51单片机为核心的控制系统进行软硬件设计与系统集成.场地和水稻田间撒肥试验结果显示,推肥板推肥角度-20°~40°可调,机器最小转弯半径1.8 m,撒肥盘离地高度可达1100 mm,撤肥幅宽达14m,作业效率达到6hm2/h,试验结果表明撒肥机适合在水田里自主行走,整机与控制系统设计满足水田宽幅高效变量撒肥工作要求.%In order to solve the problems of low ground clearance, backward manure regulation technology and low working efficiency present in paddy fertilizing machine, a self-propelled high-ground-clearance spreader was designed for paddy variable-rate fertilization, the whole structure and working mechanism of the machine were introduced, the special chassis with high ground clearance, the fertilization disc and regulation device for fertilizing orifice were designed, the structures and parameters of main components of the machine were given, the software and hardware integrated control system which mainly consists of AT89C51 single-chip microcomputer (SCM) was designed, The fertilizing experiments in grounds and paddy fields showed that the angle for pushing fertilizer board was at -20°-40°, the minimum turning radius of the machine was less than 1.8 m, the height of fertilization disc from the ground was 1100 mm, the fertilizing width of machine achieved 14 m, working efficiency was up to 6 hm2/h, the experimental results indicate that the machine is suitable for self-propelled walking in paddy fields, and the design for the machine and its control system meets variable-rate fertilization requirements of widespread distribution and high efficiency in paddy fields.

  12. Highly fluorescent resorcinarene cavitand nanocapsules with efficient renal clearance

    Science.gov (United States)

    Mahadevan, Kalpana; Patthipati, Venkata Suresh; Han, Sangbum; Swanson, R. James; Whelan, Eoin C.; Osgood, Christopher; Balasubramanian, Ramjee

    2016-08-01

    Nanomaterial based imaging approaches hold substantial promise in addressing current diagnostic and therapeutic challenges. One of the key requirements for the successful clinical translation of nanomaterials is their complete clearance from the body within a reasonable time period preferably via the renal filtration route. This article describes the synthesis of highly fluorescent, water soluble, resorcinarene cavitand nanocapsules and demonstrates their effective renal clearance in mice. The synthesis and functionalization of nanocapsules was accomplished in a one-pot operation via thiol-ene reactions without involving self-assembly, sacrificial templates or emulsions. Water soluble resorcinarene cavitand nanocapsules obtained by this approach were covalently functionalized with Alexa Fluor 750. Highly fluorescent nanocapsules with hydrodynamic diameters of 122 nm and 68 nm and extinction coefficients of 1.3 × 109 M-1 cm-1 and 1.5 × 108 M-1 cm-1 respectively were prepared by varying the reaction conditions. The in vivo biodistribution and clearance of these nanocapsules in mice followed by whole-body fluorescence imaging showed that they were both cleared renally within a few hours. Given the inherent encapsulation capabilities of nanocapsules, the renal clearance demonstrated in this work opens up new opportunities for their theranostic applications especially for targeting and treating the urinary tract.

  13. Reproducibility of CSF quantitative culture methods for estimating rate of clearance in cryptococcal meningitis.

    Science.gov (United States)

    Dyal, Jonathan; Akampurira, Andrew; Rhein, Joshua; Morawski, Bozena M; Kiggundu, Reuben; Nabeta, Henry W; Musubire, Abdu K; Bahr, Nathan C; Williams, Darlisha A; Bicanic, Tihana; Larsen, Robert A; Meya, David B; Boulware, David R

    2016-05-01

    Quantitative cerebrospinal fluid (CSF) cultures provide a measure of disease severity in cryptococcal meningitis. The fungal clearance rate by quantitative cultures has become a primary endpoint for phase II clinical trials. This study determined the inter-assay accuracy of three different quantitative culture methodologies. Among 91 participants with meningitis symptoms in Kampala, Uganda, during August-November 2013, 305 CSF samples were prospectively collected from patients at multiple time points during treatment. Samples were simultaneously cultured by three methods: (1) St. George's 100 mcl input volume of CSF with five 1:10 serial dilutions, (2) AIDS Clinical Trials Group (ACTG) method using 1000, 100, 10 mcl input volumes, and two 1:100 dilutions with 100 and 10 mcl input volume per dilution on seven agar plates; and (3) 10 mcl calibrated loop of undiluted and 1:100 diluted CSF (loop). Quantitative culture values did not statistically differ between St. George-ACTG methods (P= .09) but did for St. George-10 mcl loop (P< .001). Repeated measures pairwise correlation between any of the methods was high (r≥0.88). For detecting sterility, the ACTG-method had the highest negative predictive value of 97% (91% St. George, 60% loop), but the ACTG-method had occasional (∼10%) difficulties in quantification due to colony clumping. For CSF clearance rate, St. George-ACTG methods did not differ overall (mean -0.05 ± 0.07 log10CFU/ml/day;P= .14) on a group level; however, individual-level clearance varied. The St. George and ACTG quantitative CSF culture methods produced comparable but not identical results. Quantitative cultures can inform treatment management strategies.

  14. 78 FR 56222 - Agency Information Collection Activities; Comment Request; Highly Qualified Teachers Clearance

    Science.gov (United States)

    2013-09-12

    ... Agency Information Collection Activities; Comment Request; Highly Qualified Teachers Clearance AGENCY... notice will be considered public records. Title of Collection: Highly Qualified Teachers Clearance OMB... disadvantaged students) are taught by teachers participating in an alternative route to certification...

  15. 78 FR 67344 - Highly Qualified Teachers Clearance; Extension of Public Comment Period; Correction

    Science.gov (United States)

    2013-11-12

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF EDUCATION Highly Qualified Teachers Clearance; Extension of Public Comment Period; Correction AGENCY: Department of... comment for an information collection entitled, ``Highly Qualified Teachers Clearance,''...

  16. Creatinine clearance as a substitute for the glomerular filtration rate in the assessment of glomerular hemodynamics.

    Science.gov (United States)

    Okada, N; Imanishi, M; Yoshioka, K; Konishi, Y; Okumura, M; Tanaka, S; Fujii, S

    1999-11-01

    A method for the clinical assessment of glomerular hemodynamics has been published previously. We here examined whether, when using this method, renal creatinine clearance (Ccr) can be substituted for the glomerular filtration rate (GFR). The study subjects comprised 57 inpatients from Osaka City General Hospital: 30 with type 2 diabetes mellitus and 27 with chronic glomerulonephritis. During the 2-wk study, patients received a high-salt diet for 1 wk and a low-salt diet for 1 wk. Urinary sodium excretion and systemic blood pressure were measured daily. The renal plasma flow, Ccr, and plasma total protein concentration were also evaluated simultaneously on the last day of the high-salt diet. The GFR was also calculated from the fractional renal accumulation of 99mTc-diethylenetriaminepentaacetic acid (DTPA). Glomerular hemodynamics, represented by the glomerular capillary hydraulic pressure and the resistance of afferent and efferent arterioles, were calculated using the renal clearance, the plasma total protein concentration, and the pressure-natriuresis relationship. Values for renal hemodynamics with the Ccr-derived GFR were compared with those from the 99mTc-DTPA-derived GFR. Ccr values of 53 to 169 ml/min correlated with the 99mTc-DTPA-derived clearance of 39 to 179 ml/min (n=57, r=.71, presistances of afferent and efferent arterioles calculated using the Ccr-derived GFR correlated significantly with those calculated using the 99mTc-DTPA-derived GFR (r=.99, p<.001 and r=.99, p<.001, respectively). These results indicate that the Ccr is an accurate representation of the GFR for use in glomerular hemodynamic analysis of the pressure-natriuresis relationship.

  17. The metabolic clearance rate of corticosterone in lean and obese male Zucker rats

    Energy Technology Data Exchange (ETDEWEB)

    White, B.D.; Corll, C.B.; Porter, J.R.

    1989-06-01

    The obese Zucker rat is an animal model of human juvenile-onset obesity. These rats exhibit numerous endocrine and metabolic abnormalities. Adrenalectomy of obese rats has been shown to reduce or reverse several of these abnormalities, thereby implying that corticosterone may contribute to the expression of obesity in this animal. Furthermore, it has been shown that the circadian rhythm of plasma corticosterone is disturbed in obese Zucker rats resulting in elevated morning plasma corticosterone concentrations in obese rats as compared to lean rats. In a effort to better elucidate the mechanism of the elevated morning levels of plasma corticosterone, the metabolic clearance rate of corticosterone was determined in the morning for lean and obese male Zucker rats (12 to 20 weeks). Additionally, the biliary and urinary excretion of labeled corticosterone and/or its metabolites were determined. The metabolic clearance rate of corticosterone was significantly greater in obese rats than in their lean counterparts. Both the metabolic clearance rate and the volume of compartments significantly correlated with body weight. No correlation was found between body weight and the elimination rate constant. The increased metabolic clearance rate of obese rats appeared to be due to an increase in the physiologic distribution of corticosterone and not to an alteration in the enzymes responsible for corticosterone metabolism. It appears that the metabolic clearance rate of corticosterone in obese Zucker rats does not contribute to elevated morning concentrations of plasma corticosterone previously observed in these animals. It suggests that the adrenal corticosterone secretion rate must actually be greater than one would expect from the plasma corticosterone concentrations alone.

  18. In situ method for measurements of community clearance rate on shallow water bivalve populations

    DEFF Research Database (Denmark)

    Hansen, Benni W.; Dolmer, Per; Vismann, Bent

    2011-01-01

    An open-top chamber was designed for measuring ambient community clearance rate on undisturbed bivalve populations in the field. The chamber was pressed 5-10 cm down in the sediment on the mussel bed. It holds approximately 30-40 cm water column equal to a volume of 43-77 L. It was provided with ...

  19. Measurement of glomerular filtration rate in adults: accuracy of five single-sample plasma clearance methods

    DEFF Research Database (Denmark)

    Rehling, M; Rabøl, A

    1989-01-01

    After an intravenous injection of a tracer that is removed from the body solely by filtration in the kidneys, the glomerular filtration rate (GFR) can be determined from its plasma clearance. The method requires a great number of blood samples but collection of urine is not needed. In the present...

  20. Highly Catalytic Nanodots with Renal Clearance for Radiation Protection

    CERN Document Server

    Zhang, Xiao-Dong; Wang, Junying; Yang, Jiang; Chen, Jie; Shen, Xiu; Deng, Jiao; Deng, Dehui; Long, Wei; Sun, Yuan-Ming; Liu, Changlong; Li, Meixian

    2016-01-01

    Ionizing radiation (gamma and x-ray) is widely used in industry and medicine, but it can also pose a significant hazardous effect on health and induce cancer, physical deformity and even death, due to DNA damages and invasion of free radicals. There is therefore an urgent unmet demand in designing highly efficient radioprotectants with synergetic integration of effective renal clearance and low toxicity. In this study, we designed ultrasmall (sub-5 nm) highly catalytically active and cysteine-protected MoS2 dots as radioprotectants and investigated their application in protection against ionizing radiation. In vivo preclinical studies showed that the surviving fraction of MoS2-treated mice can appreciably increase to up to 79 % when they were exposed to high-energy ionizing radiation. Furthermore, MoS2 dots can contribute in cleaning up the accumulated free radicals within the body, repairing DNA damages and recovering all vital chemical and biochemical indicators, suggesting their unique role as free radical...

  1. Effect of Various Sugary Beverages on Salivary pH, Flow Rate, and Oral Clearance Rate amongst Adults.

    Science.gov (United States)

    Hans, Rinki; Thomas, Susan; Garla, Bharat; Dagli, Rushabh J; Hans, Manoj Kumar

    2016-01-01

    Introduction. Diet is a major aetiological factor for dental caries and enamel erosion. This study was undertaken with the aim of assessing the effect of selected locally available beverages on salivary pH, flow rate, and oral clearance rate amongst adults. Materials and Method. This clinical trial comprised 120 subjects. Test beverages undertaken were pepsi, fruit drink, coffee, and sweetened milk. Statistical analysis was carried out using SPSS version 17. Descriptive statistics, one-way ANOVA, and post hoc Tukey's test were applied in the statistical tests. Results. It was found that salivary pH decreased for all the beverages immediately after consumption and the salivary flow rate increased after their consumption. The oral clearance rate of sweetened milk was found to be the least at 6.5 minutes and that of pepsi was found to be 13 minutes. However, the oral clearance rates of fruit drink and coffee were found to be equal at 15 minutes. Conclusion. Although it was found out that liquids cleared rapidly from the oral cavity, they had a significant cariogenic and erosive potential. Hence, it is always advised to minimise the consumption of beverages, especially amongst children and young adults to maintain a good oral health.

  2. Effect of Various Sugary Beverages on Salivary pH, Flow Rate, and Oral Clearance Rate amongst Adults

    Directory of Open Access Journals (Sweden)

    Rinki Hans

    2016-01-01

    Full Text Available Introduction. Diet is a major aetiological factor for dental caries and enamel erosion. This study was undertaken with the aim of assessing the effect of selected locally available beverages on salivary pH, flow rate, and oral clearance rate amongst adults. Materials and Method. This clinical trial comprised 120 subjects. Test beverages undertaken were pepsi, fruit drink, coffee, and sweetened milk. Statistical analysis was carried out using SPSS version 17. Descriptive statistics, one-way ANOVA, and post hoc Tukey’s test were applied in the statistical tests. Results. It was found that salivary pH decreased for all the beverages immediately after consumption and the salivary flow rate increased after their consumption. The oral clearance rate of sweetened milk was found to be the least at 6.5 minutes and that of pepsi was found to be 13 minutes. However, the oral clearance rates of fruit drink and coffee were found to be equal at 15 minutes. Conclusion. Although it was found out that liquids cleared rapidly from the oral cavity, they had a significant cariogenic and erosive potential. Hence, it is always advised to minimise the consumption of beverages, especially amongst children and young adults to maintain a good oral health.

  3. Changes in glomerular filtration rate, lithium clearance and plasma protein clearances in the early phase after unilateral nephrectomy in living healthy renal transplant donors

    DEFF Research Database (Denmark)

    Strandgaard, S; Kamper, A; Skaarup, P;

    1988-01-01

    1. Glomerular and tubular function was studied before and 2 months after unilateral nephrectomy in 14 healthy kidney donors by measurement of the clearances of 51Cr-labelled ethylenediaminetetra-acetate, lithium, beta 2-microglobulin, albumin and immunoglobulin G. 2. The glomerular filtration rate...

  4. Potential Effect of Substituting Estimated Glomerular Filtration Rate for Estimated Creatinine Clearance for Dosing of Direct Oral Anticoagulants.

    Science.gov (United States)

    Schwartz, Janice B

    2016-10-01

    To determine the potential effect of substituting glomerular filtration rate (GFR) estimates for renal clearance estimated using the Cockcroft-Gault method (CrCL-CG) to calculate direct oral anticoagulant (DOAC) dosing. Simulation and retrospective data analysis. Community, academic institution, nursing home. Noninstitutionalized individuals aged 19 to 80 from the National Health and Nutrition Examination Survey (NHANES) (2011/12) (n = 4,687) and medically stable research participants aged 25 to 105 (n = 208). Age, height, weight, sex, race, serum creatinine, CrCL-CG, and GFR (according to the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration equations). Outcome measures were dosing errors if GFR were to be substituted for CrCL-CG. Renal clearance estimates according to all methods were highly correlated (P < .001), although at lower clearances, substitution of GFR estimates for CrCL-CG resulted in failure to recognize needs for dose reductions of rivaroxaban or edoxaban in 28% of NHANES subjects and 47% to 56% of research subjects. At a CrCL-CG of less than 30 mL/min, GFR estimates missed indicated dosage reductions for dabigatran in 18% to 21% of NHANES subjects and 57% to 86% of research subjects. Age and weight contributed to differences between renal clearance estimates (P < .001), but correction of GFR for body surface area (BSA) did not reduce dosing errors. At a CrCL-CG greater than 95 mL/min, edoxaban is not recommended, and GFR esimates misclassified 24% of NHANES and 39% of research subjects. Correction for BSA reduced misclassification to 7% for NHANES and 14% in research subjects. Substitution of GFR estimates for estimated CrCl can lead to failure to recognize indications for reducing DOAC dose and potentially higher bleeding rates than in randomized trials. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  5. Clearance rates of jellyfish and their potential predation impact on zooplankton and fish larvae in a neritic ecosystem (Limfjorden, Denmark)

    DEFF Research Database (Denmark)

    Hansson, L. J.; Moeslund, O.; Kiørboe, Thomas

    2005-01-01

    comparatively low. These data were used to assess the impact of jellyfish predation upon zooplankton and fish larvae in Limfjorden, Denmark. Repeated sampling of zooplankton, fish larvae and medusae was undertaken during the first half of 2003. Nine taxa of hydromedusae and 4 taxa of scyphomedusae were...... identified. Abundance estimates were combined with estimated clearance rates of individual medusae to calculate potential jellyfish-induced mortality on prey in Limfjorden. Copepoda was used as a model prey group to estimate the collective predation impact by all medusae. Medusa species with unknown...... clearance potential were given assumed clearance rate values, but the collective predation potential by these species was evaluated to be small. Hydromedusae dominated numerically and had their highest potential clearance impact in spring, but overall jellyfish clearance potential on copepods was low during...

  6. 30 CFR 77.807-1 - High-voltage powerlines; clearances above ground.

    Science.gov (United States)

    2010-07-01

    ... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-1 High-voltage powerlines; clearances above ground. High-voltage powerlines located above driveways, haulageways, and railroad tracks...

  7. Growth hormone secretion and clearance rates in growing beef steers implanted with estrogenic anabolic compounds.

    Science.gov (United States)

    Gopinath, R; Kitts, W D

    1984-01-01

    The effect of estrogenic anabolic compounds on the kinetic parameters of metabolism of growth hormone (GH) was studied in growing beef steers. Twenty-four beef steers were randomly placed into four groups and assigned to one of the following four treatment groups: zeranol, diethylstilbestrol (DES), Synovex-S and an unimplanted control. GH metabolism was studied from eight steers on day 20 following the implantation of anabolic compounds. The animals were rapidly injected with a solution of bGH (NIH-GH-B18) and the disappearance of injected GH from the plasma was monitored up to 120 min following the injection. The plasma GH disappearance curve displayed an initial rapid phase lasting 5 min and a slow disappearance phase lasting 42 min; the fractional turnover rate from the two compartments were 0.167 and 0.017 min-1, respectively. The average volume of distribution of GH in steers was 6% of the body weight. Mean values of metabolic clearance and secretion rates of GH in steers were 21 liters/h and 252 micrograms/h or 74.5 ml/kg/h and 0.91 microgram/kg/h, respectively. Steers implanted with anabolic compounds gained more rapidly (P less than 0.05) than the controls. Plasma basal GH concentration appeared to be higher in all the implanted than in the control steers. The secretion rate of GH was increased (P less than 0.05) in steers implanted with anabolic compounds when compared to control steers. The secretion rate (microgram/kg/h) was about 96% (P less than 0.05), 107% (P less than 0.05) and 81% (P less than 0.05) higher in steers implanted with DES, zeranol and Synovex-S, respectively, than in the control steers. All the compounds studied were equally effective in increasing the secretion of GH on day 20 following their implantation. Metabolic clearance rate of GH was not affected by anabolic compound implantation in steers. There was, however, a slight reduction in metabolic clearance rate due to DES and a slight elevation due to zeranol and Synovex-S when

  8. Length- and weight-dependent clearance rates of juvenile mussels ( Mytilus edulis) on various planktonic prey items

    Science.gov (United States)

    Jacobs, P.; Troost, K.; Riegman, R.; van der Meer, J.

    2015-03-01

    Filtration capacity and feeding behaviour has been intensely studied for adult mussels ( Mytilus edulis), but less information is available for juvenile mussels (1.5-25 mm, mussel seed collectors in the Netherlands prompted the need for more detailed information on juvenile mussel behaviour. To estimate the impact of juvenile populations on ecosystem carrying capacity, information on clearance rate as well as usage of different prey items is essential. Clearance rates were measured in an experimental study, incubating juvenile mussels in natural sea water. Rates were related to isometrics as well as specified for the prey items bacteria, picophytoplankton (mussels depends on shell length2, while the relationship between clearance rate and weight was more variable. Length is thus a better parameter for estimating clearance rate than weight. Ciliates and nanophytoplankton were cleared at comparable, but variable rates, while picoalgae were cleared from the water at the rate of 11-64 % compared to nanophytoplankton. For bacteria, the clearance rate was on average 9 %. This study showed different retention of particles of similar size (picoalgae and bacteria) as well as variability in particle retention for the different prey items. This variable retention efficiency could not be related to seston concentration nor to dominance in cell size. The results from this study can be used to estimate the effect of mussel seed collectors on the carrying capacity of the Dutch Wadden Sea.

  9. The clearance concept with special reference to determination of glomerular filtration rate in patients with fluid retention.

    Science.gov (United States)

    Henriksen, Ulrik L; Henriksen, Jens H

    2015-01-01

    In subjects without fluid retention, the total plasma clearance of a renal filtration indicator (inulin, (99m) Tc-DTPA, (51) Cr-EDTA) is close to the urinary plasma clearance. Conversely, in patients with fluid retention (oedema, pleural effusions, ascites), there is a substantial discrepancy between the total plasma clearance and the urinary plasma clearance. This is owing to delayed indicator distribution to smaller or larger parts of the interstitial space, which in patients with ascites may simulate a peritoneal dialysator. In patients with fluid retention, urinary plasma clearance should be assessed to obtain a correct measurement of the glomerular filtration rate (GFR). In theory, total plasma clearance with late samples (24-h, 48-h) may be applied in patients with fluid retention, but validation hereof has not been performed. Until such studies are completed, it is recommended that patients with fluid retention have their GFR measured by a urinary plasma clearance technique with controlled quantitative urinary sampling within a few hours after indicator injection.

  10. Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?

    Science.gov (United States)

    Delanaye, Pierre; Ebert, Natalie; Melsom, Toralf; Gaspari, Flavio; Mariat, Christophe; Cavalier, Etienne; Björk, Jonas; Christensson, Anders; Nyman, Ulf; Porrini, Esteban; Remuzzi, Giuseppe; Ruggenenti, Piero; Schaeffner, Elke; Soveri, Inga; Sterner, Gunnar; Eriksen, Bjørn Odvar; Bäck, Sten-Erik

    2016-01-01

    While there is general agreement on the necessity to measure glomerular filtration rate (GFR) in many clinical situations, there is less agreement on the best method to achieve this purpose. As the gold standard method for GFR determination, urinary (or renal) clearance of inulin, fades into the background due to inconvenience and high cost, a diversity of filtration markers and protocols compete to replace it. In this review, we suggest that iohexol, a non-ionic contrast agent, is most suited to replace inulin as the marker of choice for GFR determination. Iohexol comes very close to fulfilling all requirements for an ideal GFR marker in terms of low extra-renal excretion, low protein binding and in being neither secreted nor reabsorbed by the kidney. In addition, iohexol is virtually non-toxic and carries a low cost. As iohexol is stable in plasma, administration and sample analysis can be separated in both space and time, allowing access to GFR determination across different settings. An external proficiency programme operated by Equalis AB, Sweden, exists for iohexol, facilitating interlaboratory comparison of results. Plasma clearance measurement is the protocol of choice as it combines a reliable GFR determination with convenience for the patient. Single-sample protocols dominate, but multiple-sample protocols may be more accurate in specific situations. In low GFRs one or more late samples should be included to improve accuracy. In patients with large oedema or ascites, urinary clearance protocols should be employed. In conclusion, plasma clearance of iohexol may well be the best candidate for a common GFR determination method. PMID:27679715

  11. Measurement of glomerular filtration rate, renal plasma flow, and endogenous creatinine clearance in cheetahs (Acinonyx jubatus jubatus).

    Science.gov (United States)

    Holder, Erin Hall; Citino, Scott B; Businga, Nancy; Cartier, Leslie; Brown, Scott A

    2004-06-01

    Glomerular filtration rate (GFR), renal plasma flow (RPF), and the endogenous creatinine clearance (CCr) rate were determined in 13 captive cheetahs, Acinonyx jubatus jubatus (seven females and six males, 1.5-7.5 yr of age, x = 5.02 yr), during general anesthesia with Telazol and isoflurane by measuring the urinary clearances of inulin, para-aminohipppuric acid, and endogenous creatinine, respectively. Methods to determine GFR, RPF, and endogenous CCr in captive cheetahs were evaluated, and the relationship between GFR and CCr for this species was determined. The GFR and the RPF were stable during the procedure, with mean values of 1.59+/-0.17 ml/min/kg body weight and 5.12+/-1.15 ml/min/kg body weight, respectively. Although the mean value for CCr (1.47+/-0.20 ml/min/kg body weight) was significantly less than the corresponding value for GFR, the mean difference (0.11+/-0.02 ml/min/kg weight) between the two measurements was slight, and the values were highly correlated (R2 = 0.928; P cheetahs should provide a reliable estimate of GFR, facilitating the early detection of renal disease in this species.

  12. Measurement of glomerular filtration rate in adults: accuracy of five single-sample plasma clearance methods

    DEFF Research Database (Denmark)

    Rehling, M; Rabøl, A

    1989-01-01

    After an intravenous injection of a tracer that is removed from the body solely by filtration in the kidneys, the glomerular filtration rate (GFR) can be determined from its plasma clearance. The method requires a great number of blood samples but collection of urine is not needed. In the present......-acetate) was determined simultaneously. Using these clearance values as reference the accuracy of six simplified methods were studied: five single-sample methods and one five-sample method. The standard error of estimate (SEE) of the single-sample methods ranged from 4.2 to 7.5 ml min-1 using EDTA, and from 3.8 to 6.3 ml...... min-1 using DTPA. SEE of the five-samples method was 3.0 ml min-1 (EDTA) and 3.1 ml min-1 (DTPA). The single-sample methods given by Christensen & Groth (1986) and by Tauxe (1986) are recommended for daily use, as SEE was small even at low GFR values. In patients with GFR less than 80 ml min-1...

  13. Mucociliary clearance

    DEFF Research Database (Denmark)

    Munkholm, Mathias; Mortensen, Jann

    2014-01-01

    Mucociliary clearance has long been known to be a significant innate defence mechanism against inhaled microbes and irritants. Important knowledge has been gathered regarding the anatomy and physiology of this system, and in recent years, extensive studies of the pathophysiology related to lung...... pharmacological interventions on clearance rate, to study the importance of defective mucus clearance in different lung diseases or as a diagnostic tool in the work-up of patients with recurrent airway diseases. The aim of this review is to provide an overview of the anatomy, physiology, pathophysiology...

  14. Cell surface structures influence lung clearance rate of systemically infused mesenchymal stromal cells.

    Science.gov (United States)

    Nystedt, Johanna; Anderson, Heidi; Tikkanen, Jonne; Pietilä, Mika; Hirvonen, Tia; Takalo, Reijo; Heiskanen, Annamari; Satomaa, Tero; Natunen, Suvi; Lehtonen, Siri; Hakkarainen, Tanja; Korhonen, Matti; Laitinen, Saara; Valmu, Leena; Lehenkari, Petri

    2013-02-01

    The promising clinical effects of mesenchymal stromal/stem cells (MSCs) rely especially on paracrine and nonimmunogenic mechanisms. Delivery routes are essential for the efficacy of cell therapy and systemic delivery by infusion is the obvious goal for many forms of MSC therapy. Lung adhesion of MSCs might, however, be a major obstacle yet to overcome. Current knowledge does not allow us to make sound conclusions whether MSC lung entrapment is harmful or beneficial, and thus we wanted to explore MSC lung adhesion in greater detail. We found a striking difference in the lung clearance rate of systemically infused MSCs derived from two different clinical sources, namely bone marrow (BM-MSCs) and umbilical cord blood (UCB-MSCs). The BM-MSCs and UCB-MSCs used in this study differed in cell size, but our results also indicated other mechanisms behind the lung adherence. A detailed analysis of the cell surface profiles revealed differences in the expression of relevant adhesion molecules. The UCB-MSCs had higher expression levels of α4 integrin (CD49d, VLA-4), α6 integrin (CD49f, VLA-6), and the hepatocyte growth factor receptor (c-Met) and a higher general fucosylation level. Strikingly, the level of CD49d and CD49f expression could be functionally linked with the lung clearance rate. Additionally, we saw a possible link between MSC lung adherence and higher fibronectin expression and we show that the expression of fibronectin increases with MSC culture confluence. Future studies should aim at developing methods of transiently modifying the cell surface structures in order to improve the delivery of therapeutic cells.

  15. Factors influencing a low rate of hepatitis C viral RNA clearance in heroin users from Southern China

    Institute of Scientific and Technical Information of China (English)

    ShengHan Lai; Jin-Bing Zhang; Wei Liu; Jie Chen; Xiao-Fang Yu

    2008-01-01

    AIM: To study the virological and host factors influencing hepatitis C infection outcomes in heroin users in southern China.METHODS: HCV RNA and associated factors were analyzed among 347 heroin users from Guangxi Zhuang Autonomous Region, southern China who were hepatitis C virus (HCV) EIA positive for two or more consecutive visits.RESULTS: Using the COBAS AMPLICOR HCV TEST, a remarkably low HCV RNA negative rate of 8.6% was detected. After multivariate logistic regression analysis, HCV RNA clearance was significantly associated with the presence of HBsAg (OR = 8.436, P < 0.0001), the lack of HIV-1 infection (OR = 0.256, P = 0.038) and age younger than 25 (OR = 0.400, P = 0.029).CONCLUSION: Our study suggests HCV infection among Chinese heroin users results in high levels of viral persistence even amidst factors previously found to enhance viral clearance. Prospective studies of a possible genetic component within the Chinese population and the pathogenicity of non-genotype 1 HCV infections are needed.

  16. Clearance rates of ephyrae and small medusae of the common jellyfish Aurelia aurita offered different types of prey

    Science.gov (United States)

    Riisgård, Hans Ulrik; Madsen, Caroline V.

    2011-01-01

    Prey selection and knowledge of the amounts of water processed by the early stages of the common jellyfish Aurelia aurita may at certain times of the year be crucial for understanding the plankton dynamics in marine ecosystems with mass occurrences of this jellyfish. In the present study we used two different methods ("clearance method" and "ingestion-rate method") to estimate the amount of water cleared per unit of time of different types and sizes of prey organisms offered to A. aurita ephyrae and small medusae. The mean clearance rates of medusae, estimated with Artemia sp. nauplii as prey by both methods, agreed well, namely 3.8 ± 1.4 l h - 1 by the clearance method and 3.2 ± 1.1 l h - 1 by the ingestion-rate method. Both methods showed that copepods (nauplii and adults) and mussel veligers are captured with considerably lower efficiency, 22 to 37% and 14 to 30%, respectively, than Artemia salina nauplii. By contrast, the water processing rates of ephyrae measured by the clearance method with A. salina nauplii as prey were 3 to 5 times lower than those measured by the ingestion-rate method. This indicates that the prerequisite of full mixing for using the clearance method may not have been fulfilled in the ephyrae experiments. The study demonstrates that the predation impact of the young stages of A. aurita is strongly dependent on its developmental stage (ephyra versus medusa), and the types and sizes of prey organisms. The estimated prey-digestion time of 1.3 h in a steady-state feeding experiment with constant prey concentration supports the reliability of the ingestion-rate method, which eliminates the negative "container effects" of the clearance method, and it seems to be useful in future jellyfish studies, especially on small species/younger stages in which both type and number of prey can be easily and precisely assessed.

  17. Prognostic significance of early lactate clearance rate for severe acute respiratory failure patients on extracorporeal membrane oxygenation

    Institute of Scientific and Technical Information of China (English)

    臧芝栋

    2014-01-01

    Objective To investigate the prognostic significanceof early lactate clearance rate for severe acute respiratory failure patients on extracorporeal membrane oxygenation(ECMO).Methods Forty-three patients with severe acute respiratory failure supported by venous-venous(v-v)ECMO were enrolled from January 2007 to January 2013.Arterial blood lactate at pre-ECMO support(0 h)and at

  18. Spontaneous viral clearance after 6-21 years of hepatitis B and C viruses coinfection in high HBV endemic area

    Institute of Scientific and Technical Information of China (English)

    Chun-Lei Fan; Lai Wei; Dong Jiang; Hong-Song Chen; Yan Gao; Ruo-Bing Li; Yu Wang

    2003-01-01

    AIM: To investigate the clinical and virological course of coinfection by hepatitis B virus (HBV) and hepatitis C virus (HCV) in China.METHODS: We enrolled 40 patients with chronic HBV and HCV coinfection (Group BC), 16 patients with chronic HBV infection (Group B) and 31 patients with chronic HCV infection (Group C). They infected HBV and/or HCV during 1982 to 1989.Sera of all the 87 patients were collected in 1994 and 2002respectively. We detected biochemical and virologic markers and serum HBV DNA and HCV RNA levels of all the patients. Btype ultrasound detection was performed in some patients.RESULTS: In Group BC, 67.5% of the patients cleared HBsAg,and 92.5% of the patients cleared HBeAg. The clearance rate of HBV DNA was 87.5%. There was no significant difference of HBV clearance between Group BC and Group B. In Group BC, 85.7% of males and 47.4% of females cleared HBV, and males were easier to clear HBV (x2=6.686, P=0.010). Such a tendency was also found in Group B. The clearance rate of HCV RNA in Group BC was 87.5%, significantly higher than that in Group C (x2=22.963, P<0.001). Less than 40% of the patients in all groups had elevated liver enzyme values. The highest value of alanine aminotransferase (ALT) was 218 u/L (normal range for ALT is 0-40 u/L). In most patients the ultrasonogram presentations changed mildly.CONCLUSION: The clinical manifestations of patients with HBV/HCV coinfection are mild and occult. High clearance rate of HBV and easy to clear HBV in male patients are the characteristics of HBV infection in adults in China. HBV can inhibit HCV replication, but no evidence has been found in our data that HCV suppresses HBV replication.

  19. [A retrospective study on HBsAg clearance rate after antiviral therapy in children with HBeAg-positive chronic hepatitis B aged 1-7 years].

    Science.gov (United States)

    Zhu, S S; Dong, Y; Xu, Z Q; Wang, L M; Chen, D W; Gan, Y; Wang, F C; Yan, J G; Cao, L L; Wang, P; Zhang, H F

    2016-10-20

    Objective: To investigate the HBsAg clearance rate after antiviral therapy in children with HBeAg-positive chronic hepatitis B (CHB) aged 1-7 years. Methods: A retrospective analysis was performed for the HBsAg clearance rate in 293 children who were hospitalized in 302 Hospital of PLA from June 2006 to December 2013, met the inclusion criteria, received antiviral therapy, and were followed up for at least 6 months after the withdrawal of antiviral therapy. The t-test or the rank sum test was applied according to the distribution of continuous data, and the chi-square test was used for comparison of categorical data. Results: The HBsAg positive rate of children's mothers was 91.1%. In the age groups of >1-≤2 years, >2-≤3 years, >3-≤4 years, >4-≤5 years, >5-≤6 years, and >6-≤7 years, the HBsAg clearance rates were 66.1%, 65.5%, 45.7%, 41.3%, 20.6%, and 27.6%, respectively. There were significant differences in HBsAg clearance rate between the age groups of >1-≤3 years and >3-≤5 years, >1-≤3 years and >5-≤7 years, and >3-≤5 years and >5-≤7 years (P = 0.001, 0.000, and 0.008). Of all children, 64.8% were boys, among whom 41.1% achieved HBsAg clearance, and 35.2% were girls, among whom 61.2% achieved HBsAg clearance; there was a significant difference in HBsAg clearance rate between boys and girls (P = 0.001). The children with pretreatment alanine aminotransferase (ALT) levels of ≤80 IU/L, > 80 IU/L, ≤200 IU/L, and > 200 IU/L had HBsAg clearance rates of 40.7%, 51.2%, 47.6%, and 49.4%, respectively; there were no significant differences in HBsAg clearance rate between the ALT ≤80 IU/L and ALT > 80 IU/L groups and the ALT ≤200 IU/L and ALT > 200 IU/L groups (P = 0.101 and 0.778). There was no significant difference in HBsAg clearance rate between the pretreatment HBV DNA load clearance rate of 57.1%, and 85% had genotype C and an HBsAg clearance rate of 39.5%; there was no significant difference in HBsAg clearance rate between the

  20. Role of Mechanical Stress in Regulating Airway Surface Hydration and Mucus Clearance Rates

    Science.gov (United States)

    Button, Brian; Boucher, Richard C.

    2008-01-01

    Effective clearance of mucus is a critical innate airway defense mechanism, and under appropriate conditions, can be stimulated to enhance clearance of inhaled pathogens. It has become increasingly clear that extracellular nucleotides (ATP and UTP) and nucleosides (adenosine) are important regulators of mucus clearance in the airways as a result of their ability to stimulate fluid secretion, mucus hydration, and cilia beat frequency (CBF). One ubiquitous mechanism to stimulate ATP release is through external mechanical stress. This article addresses the role of physiologically-relevant mechanical forces in the lung and their effects on regulating mucociliary clearance (MCC). The effects of mechanical forces on the stimulating ATP release, fluid secretion, CBF, and MCC are discussed. Also discussed is evidence suggesting that airway hydration and stimulation of MCC by stress-mediated ATP release may play a role in several therapeutic strategies directed at improving mucus clearance in patients with obstructive lung diseases, including cystic fibrosis (CF) and chronic obstructive pulmonary disease (COPD). PMID:18585484

  1. Ingestion rate and gut clearance in the planktonic copepod Centropages hamatus in relation to food concentration and temperature

    DEFF Research Database (Denmark)

    Kiørboe, Thomas; Møhlenberg, F.; Nicolajsen, Hanne

    1982-01-01

    .degree. C. Within the temperature interval studied (1.degree.-15.degree. C), maximum ingestion rate increased with temperature with a Q10 of 3.9. Gut clearance was estimated by following the exponential decrease in the gut content of plant pigments (measured fluorimetrically) with time after feeding...... be considered an estimate of ingestion rate, yielded values similar to ingestion rates actually measured. This implies that in situ algal ingestion rates may be estimated from measurements of the content of plant pigments in the guts of freshly caught copepods....

  2. High Phenobarbital Clearance During Continuous Renal Replacement Therapy

    Science.gov (United States)

    Rosenborg, Staffan; Saraste, Lars; Wide, Katarina

    2014-01-01

    Abstract Phenobarbital is an old antiepileptic drug used in severe epilepsy. Despite this, little is written about the need for dose adjustments in renal replacement therapy. Most sources recommend a moderately increased dose guided by therapeutic drug monitoring. A 14 year old boy with nonketotic hyperglycinemia, a rare inborn error of metabolism, characterized by high levels of glycine, epilepsy, spasticity, and cognitive impairment, was admitted to the emergency department with respiratory failure after a few days of fever and cough. The boy was unconscious at admittance and had acute renal and hepatic failure. Due to the acute respiratory infection, hypoxic hepatic and renal failure occurred and the patient had a status epilepticus. The patient was intubated and mechanically ventilated. Continuous renal replacement therapy was initiated. Despite increased phenobarbital doses, therapeutic levels were not reached until the dose was increased to 500 mg twice daily. Therapeutic drug monitoring was performed in plasma and dialysate. Calculations revealed that phenobarbital was almost freely dialyzed. Correct dosing of drugs in patients on renal replacement therapy may need a multidisciplinary approach and guidance by therapeutic drug monitoring. PMID:25101986

  3. Reduced effectiveness of escitalopram in the forced swimming test is associated with increased serotonin clearance rate in food-restricted rats.

    Science.gov (United States)

    France, Charles P; Li, Jun-Xu; Owens, William A; Koek, Wouter; Toney, Glenn M; Daws, Lynette C

    2009-07-01

    Efficacy of antidepressant drugs is often limited. One of the limiting factors may be diet. This study shows that the effect of escitalopram in the forced swimming test is diminished in rats by food restriction that decreased body weight by 8%. The primary target for escitalopram is the serotonin (5-HT) transporter. Using high-speed chronoamperometry to measure 5-HT clearance in vivo in rats fed the same food-restricted diet, the rate of 5-HT clearance from extracellular fluid in brain was dramatically increased. Increased 5-HT transporter function under conditions of dietary restriction might contribute to the decreased effect of escitalopram. These results suggest that diet plays an integral role in determining efficacy of antidepressant drugs, and might well generalize to other psychoactive drugs that impinge upon the 5-HT transporter.

  4. Nasal high flow reduces hypercapnia by clearance of anatomical dead space in a COPD patient.

    Science.gov (United States)

    Fricke, Kathrin; Tatkov, Stanislav; Domanski, Ulrike; Franke, Karl-Josef; Nilius, Georg; Schneider, Hartmut

    2016-01-01

    Chronic obstructive pulmonary disease (COPD) with hypercapnia is associated with increased mortality. Non-invasive ventilation (NIV) can lower hypercapnia and ventilator loads but is hampered by a low adherence rate leaving a majority of patients insufficiently treated. Recently, nasal high flow (NHF) has been introduced in the acute setting in adults, too. It is an open nasal cannula system for delivering warm and humidified air or oxygen at high flow rates (2-50 L/min) assisting ventilation. It was shown that this treatment can improve hypercapnia. The mechanism of reducing arterial carbon dioxide (CO2) is proposed through a reduction in nasal dead space ventilation, but there are no studies in which dead space volume was measured in spontaneously breathing subjects. In our case report we measured in a tracheostomized COPD patient CO2 and pressure via sealed ports in the tracheostomy cap and monitored transcutaneous CO2 and tidal volumes. NHF (30 L/min mixed with 3 L/min oxygen) was administered repeatedly at 15-minutes intervals. Inspired CO2 decreased instantly with onset of NHF, followed by a reduction in transcutaneous/arterial CO2. Minute ventilation on nasal high flow was also reduced by 700 ml, indicating that nasal high flow led to a reduction of dead space ventilation thereby improving alveolar ventilation. In conclusion, NHF assist ventilation through clearance of anatomical dead space, which improves alveolar ventilation. Since the reduction in hypercapnia was similar to that reported with effective NIV treatment NHF may become an alternative to NIV in hypercapnic respiratory failure.

  5. Solute clearance effect of citrate anticoagulation hemodialysate for hemodialysis in patients with high risk of bleeding

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Objective To study the solute clearance effect of the new concentrated anticoagulation hemodialysate of citrate for hemodialysis in patients with high risk of bleeding. Methods Forty-two kidney failure patients with high risk of bleeding were divided into two groups (Group A and Group B) according to their hemodialysis manners. Patients in Group A were hemodialyzed with bicarbonate hemodialysate with low-molecular-weight heparin (dalteparin) anticoagulation and those in Group B with the new citrate anticoag...

  6. A clinical pilot study: high frequency chest wall oscillation airway clearance in patients with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Chaisson, Kathleen Marya; Walsh, Susan; Simmons, Zachary; Vender, Robert L

    2006-06-01

    Respiratory complications are common in patients with amyotrophic lateral sclerosis (ALS) with respiratory failure representing the most common cause of death. Ineffective airway clearance resultant from deficient cough frequently contributes to these abnormalities. We sought to evaluate the effectiveness of high frequency chest wall oscillation (HFCWO) administered through the Vest Airway Clearance System when added to standard care in preventing pulmonary complications and prolonging the time to death in patients with ALS. This is a single center study performed at the Penn State Milton S. Hershey Medical Center (HMC). Nine patients with a diagnosis of ALS and concurrently receiving non-invasive ventilatory support with bi-level positive airway pressure (BiPAP) were recruited from the outpatient clinic at HMC. Four patients were randomized to receive standard care and five patients to receive standard care plus the addition of HFCWO administered twice-daily for 15 min duration. Longitudinal assessments of oxyhemoglobin saturation, forced vital capacity (FVC), and adverse events were obtained until time of death. Pulmonary complications of atelectasis, pneumonia, hospitalization for a respiratory-related abnormality, and tracheostomy with mechanical ventilation were monitored throughout the study duration. No differences were observed between treatment groups in relation to the rate of decline in FVC. The addition of HFCWO airway clearance failed to improve time to death compared to standard treatment alone (340 days +/- 247 vs. 470 days +/- 241; p = 0.26). The random allocation of HFCWO airway clearance to patients with ALS concomitantly receiving BiPAP failed to attain any significant clinical benefits in relation to either loss of lung function or mortality. This study does not exclude the potential benefit of HFCWO in select patients with ALS who have coexistent pulmonary diseases, pre-existent mucus-related pulmonary complications, or less severe levels of

  7. Computers in the Cop Car: Impact of the Mobile Digital Terminal Technology on Motor Vehicle Theft Clearance and Recovery Rates in a Texas City.

    Science.gov (United States)

    Nunn, Samuel

    1993-01-01

    Assessed the impact of the Mobile Digital Terminal technology (computers used to communicate with remote crime databases) on motor vehicle theft clearance (arresting a perpetrator) and recovery rates in Fort Worth (Texas), using a time series analysis. Impact has been ambiguous, with little evidence of improved clearance or recovery. (SLD)

  8. Determination of prey capture rates in the stony coral Galaxea fascicularis: a critical reconsideration of the clearance rate concept

    NARCIS (Netherlands)

    Osinga, R.; Delft, van S.; Lewaru, M.W.; Janse, M.; Verreth, J.A.J.

    2012-01-01

    In order to determine optimal feeding regimes for captive corals, prey capture by the scleractinian coral Galaxea fascicularis was determined by measuring clearance of prey items from the surrounding water. Colonies of G. fascicularis (sized between 200 and 400 polyps) were incubated in 1300 ml incu

  9. Increased plasma clearance rate of thyroxine despite decreased 5'-monodeiodination: study with a peroxisome proliferator in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, C.A.; Seydoux, J.; Giacobino, J.P.; Girardier, L.; Burger, A.G.

    1988-03-01

    In euthyroid rats a 17-day treatment with nafenopin, a hypolipidemic agent and peroxisome proliferator, decreased serum total and free T4 concentrations to 32 +/- 5% and 62 +/- 8% (mean +/- SEM; n = 10), respectively, with no change in serum T3 and TSH concentrations. In methimazole-treated rats infused with 3 nmol T4/day/100 g BW, the nafenopin inhibitory effect was not significantly different from that in euthyroid rats. Nafenopin treatment had the following effects on peripheral T4 and T3 metabolism in euthyroid rats. The plasma clearance rate of T4 (PCR), which was measured by Alzet minipump infusion of tracer, was increased 2-fold (1.58 +/- 0.09 vs. 0.82 +/- 0.06 ml/h.100 g BW; P less than 0.001; n = 5), while the PCR of T3 was decreased (37.5 +/- 1.3 vs. 53.8 +/- 1.8; P less than 0.001; n = 5). The fecal clearance rate of radioactivity derived from T4 was increased 2-fold (1.93 +/- 0.10 vs. 0.77 +/- 0.07 ml/h.100 g BW), whereas the urinary clearance rate was not significantly modified. The 5'-deiodinase (5'D) activity, measured by deiodination of labeled rT3, was strongly inhibited in liver and kidney, not modified in brown fat and anterior pituitary, and increased in cerebral cortex. In methimazole-treated rats substituted with isopropyl-diiodothyronine only hepatic 5'D activity was decreased. It is concluded that the decrease in serum total and free T4, without alteration in serum T3 and TSH concentrations, resulting from nafenopin treatment is mainly due to changes in peripheral T4 and T3 metabolism, since it is also observed in T4-substituted animals. The increased PCR of T4 cannot be explained by an increase in deiodination activity, since the major 5'D pathways are inhibited after nafenopin treatment, and the urinary clearance rate is not modified. It can partly be explained by an increase in the fecal clearance rate of T4, which could be due to an increase in glucoronoconjugation.

  10. A Parametric Study of Actuator Requirements for Active Turbine Tip Clearance Control of a Modern High Bypass Turbofan Engine

    Science.gov (United States)

    Kratz, Jonathan L.; Chapman, Jeffryes W.; Guo, Ten-Huei

    2017-01-01

    The efficiency of aircraft gas turbine engines is sensitive to the distance between the tips of its turbine blades and its shroud, which serves as its containment structure. Maintaining tighter clearance between these components has been shown to increase turbine efficiency, increase fuel efficiency, and reduce the turbine inlet temperature, and this correlates to a longer time-on-wing for the engine. Therefore, there is a desire to maintain a tight clearance in the turbine, which requires fast response active clearance control. Fast response active tip clearance control will require an actuator to modify the physical or effective tip clearance in the turbine. This paper evaluates the requirements of a generic active turbine tip clearance actuator for a modern commercial aircraft engine using the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) software that has previously been integrated with a dynamic tip clearance model. A parametric study was performed in an attempt to evaluate requirements for control actuators in terms of bandwidth, rate limits, saturation limits, and deadband. Constraints on the weight of the actuation system and some considerations as to the force which the actuator must be capable of exerting and maintaining are also investigated. From the results, the relevant range of the evaluated actuator parameters can be extracted. Some additional discussion is provided on the challenges posed by the tip clearance control problem and the implications for future small core aircraft engines.

  11. Applicability of estimating glomerular filtration rate equations in pediatric patients: comparison with a measured glomerular filtration rate by iohexol clearance.

    Science.gov (United States)

    Deng, Fang; Finer, Gal; Haymond, Shannon; Brooks, Ellen; Langman, Craig B

    2015-03-01

    Estimating glomerular filtration rate (eGFR) has become popular in clinical medicine as an alternative to measured GFR (mGFR), but there are few studies comparing them in clinical practice. We determined mGFR by iohexol clearance in 81 consecutive children in routine practice and calculated eGFR from 14 standard equations using serum creatinine, cystatin C, and urea nitrogen that were collected at the time of the mGFR procedure. Nonparametric Wilcoxon test, Spearman correlation, Bland-Altman analysis, bias (median difference), and accuracy (P15, P30) were used to compare mGFR with eGFR. For the entire study group, the mGFR was 77.9 ± 38.8 mL/min/1.73 m(2). Eight of the 14 estimating equations demonstrated values without a significant difference from the mGFR value and demonstrated a lower bias in Bland-Altman analysis. Three of these 8 equations based on a combination of creatinine and cystatin C (Schwartz et al. New equations to estimate GFR in children with CKD. J Am Soc Nephrol 2009;20:629-37; Schwartz et al. Improved equations estimating GFR in children with chronic kidney disease using an immunonephelometric determination of cystatin C. Kidney Int 2012;82:445-53; Chehade et al. New combined serum creatinine and cystatin C quadratic formula for GFR assessment in children. Clin J Am Soc Nephrol 2014;9:54-63) had the highest accuracy with approximately 60% of P15 and 80% of P30. In 10 patients with a single kidney, 7 with kidney transplant, and 11 additional children with short stature, values of the 3 equations had low bias and no significant difference when compared with mGFR. In conclusion, the 3 equations that used cystatin C, creatinine, and growth parameters performed in a superior manner over univariate equations based on either creatinine or cystatin C and also had good applicability in specific pediatric patients with single kidneys, those with a kidney transplant, and short stature. Thus, we suggest that eGFR calculations in pediatric clinical practice

  12. Mechanisms of astrocytic K(+) clearance and swelling under high extracellular K(+) concentrations.

    Science.gov (United States)

    Murakami, Shingo; Kurachi, Yoshihisa

    2016-03-01

    In response to the elevation of extracellular K(+) concentration ([K(+)]out), astrocytes clear excessive K(+) to maintain conditions necessary for neural activity. K(+) clearance in astrocytes occurs via two processes: K(+) uptake and K(+) spatial buffering. High [K(+)]out also induces swelling in astrocytes, leading to edema and cell death in the brain. Despite the importance of astrocytic K(+) clearance and swelling, the underlying mechanisms remain unclear. Here, we report results from a simulation analysis of astrocytic K(+) clearance and swelling. Astrocyte models were constructed by incorporating various mechanisms such as intra/extracellular ion concentrations of Na(+), K(+), and Cl(-), cell volume, and models of Na,K-ATPase, Na-K-Cl cotransporter (NKCC), K-Cl cotransporter, inwardly-rectifying K(+) (KIR) channel, passive Cl(-) current, and aquaporin channel. The simulated response of astrocyte models under the uniform distribution of high [K(+)]out revealed significant contributions of NKCC and Na,K-ATPase to increases of intracellular K(+) and Cl(-) concentrations, and swelling. Moreover, we found that, under the non-uniform distribution of high [K(+)]out, KIR channels localized at synaptic clefts absorbed excess K(+) by depolarizing the equivalent potential of K(+) (E K) above membrane potential, while K(+) released through perivascular KIR channels was enhanced by hyperpolarizing E K and depolarizing membrane potential. Further analysis of simulated drug effects revealed that astrocyte swelling was modulated by blocking each of the ion channels and transporters. Our simulation analysis revealed controversial mechanisms of astrocytic K(+) clearance and swelling resulting from complex interactions among ion channels and transporters.

  13. The role of tip clearance in high-speed fan stall

    Energy Technology Data Exchange (ETDEWEB)

    Adamczyk, J.J. (NASA Lewis Research Center, Cleveland, OH (United States)); Celestina, M.L. (Sverdrup Tech., Inc., Cleveland, OH (United States)); Greitzer, E.M. (Massachusetts Institute of Technology, Cambridge, MA (United States))

    1993-01-01

    A numerical experiment has been carried out to define the near-stall casing endwall flow field of a high-speed fan rotor. The experiment used a simulation code incorporating a simple clearance model, whose calibration is presented. The results of the simulation show that the interaction of the tip leakage vortex and the in-passage shock plays a major role in determining the fan flow range. More specifically, the computations imply that it is the area increase of this vortex as it passes through the in-passage shock that is the source of the blockage associated with stall. In addition, for fans of this type, it is the clearance over the forward portion of the fan blade that controls the flow processes leading to stall.

  14. The role of tip clearance in high-speed fan stall

    Science.gov (United States)

    Adamczyk, J. J.; Celestina, M. L.; Greitzer, E. M.

    1991-01-01

    A numerical experiment has been carried out to define the near-stall casing endwall flowfield of a high-speed fan rotor. The experiment used a simulation code incorporating a simple clearance model, whose calibration is presented. The results of the simulation show that the interaction of the tip leakage vortex and the in-pasage shock plays a major role in determining the fan flow range. More specifically, the computations imply that it is the area increase of this vortex as it passes through the in-passage shock, which is the source of the blockage associated with stall. In addition, for fans of this type, it is the clearance over the forward portion of the fan blade which controls the flow processes leading to stall.

  15. Bile acid sequestration reduces plasma glucose levels in db/db mice by increasing its metabolic clearance rate.

    Directory of Open Access Journals (Sweden)

    Maxi Meissner

    Full Text Available AIMS/HYPOTHESIS: Bile acid sequestrants (BAS reduce plasma glucose levels in type II diabetics and in murine models of diabetes but the mechanism herein is unknown. We hypothesized that sequestrant-induced changes in hepatic glucose metabolism would underlie reduced plasma glucose levels. Therefore, in vivo glucose metabolism was assessed in db/db mice on and off BAS using tracer methodology. METHODS: Lean and diabetic db/db mice were treated with 2% (wt/wt in diet Colesevelam HCl (BAS for 2 weeks. Parameters of in vivo glucose metabolism were assessed by infusing [U-(13C]-glucose, [2-(13C]-glycerol, [1-(2H]-galactose and paracetamol for 6 hours, followed by mass isotopologue distribution analysis, and related to metabolic parameters as well as gene expression patterns. RESULTS: Compared to lean mice, db/db mice displayed an almost 3-fold lower metabolic clearance rate of glucose (p = 0.0001, a ∼300% increased glucokinase flux (p = 0.001 and a ∼200% increased total hepatic glucose production rate (p = 0.0002. BAS treatment increased glucose metabolic clearance rate by ∼37% but had no effects on glucokinase flux nor total hepatic or endogenous glucose production. Strikingly, BAS-treated db/db mice displayed reduced long-chain acylcarnitine content in skeletal muscle (p = 0.0317 but not in liver (p = 0.189. Unexpectedly, BAS treatment increased hepatic FGF21 mRNA expression 2-fold in lean mice (p = 0.030 and 3-fold in db/db mice (p = 0.002. CONCLUSIONS/INTERPRETATION: BAS induced plasma glucose lowering in db/db mice by increasing metabolic clearance rate of glucose in peripheral tissues, which coincided with decreased skeletal muscle long-chain acylcarnitine content.

  16. Over-estimation of glomerular filtration rate by single injection [51Cr]EDTA plasma clearance determination in patients with ascites

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Brøchner-Mortensen, J; Malchow-Møller, A;

    1980-01-01

    The total plasma (Clt) and the renal plasma (Clr) clearances of [51Cr]EDTA were determined simultaneously in nine patients with ascites due to liver cirrhosis. Clt (mean 78 ml/min, range 34-115 ml/min) was significantly higher than Clr (mean 52 ml/min, range 13-96 ml/min, P .... To assess glomerular filtration rate in presence of ascites, the renal plasma clearance of [51Cr]EDTA should be used instead of the total plasma clearance....

  17. Natural history of human papillomavirus infection in non-vaccinated young males: low clearance probability in high-risk genotypes.

    Science.gov (United States)

    Cai, T; Perletti, G; Meacci, F; Magri, V; Verze, P; Palmieri, A; Mazzoli, S; Santi, R; Nesi, G; Mirone, V; Bartoletti, R

    2016-03-01

    In this study, we aimed to investigate the clearance of type-specific genital human papillomavirus (HPV) infection in heterosexual, non-HPV-vaccinated males whose female partners were positive to HPV DNA tests. All consecutive men attending the same sexually transmitted diseases (STD) centre between January 2005 and December 2006 were considered for this study. All subjects (n = 1009) underwent a urologic visit and microbiological tests on first void, midstream urine and total ejaculate samples. One hundred and five patients were positive for HPV DNA (10.4 %; mean age: 34.8 ± 5.8 years) and consented to clinical examination and molecular diagnostic assays for HPV detection scheduled every 6 months (median surveillance period of 53.2 months). HPV genotypes were classified as high risk, probable high risk and low risk. HPV-positive samples which did not hybridise with any of the type-specific probes were referred to as positive non-genotypeable. At enrollment, the distribution of HPV genotypes was as follows: high-risk HPV (n = 37), probable high-risk HPV (n = 6), low-risk HPV (n = 23) and non-genotypeable HPV (n = 39). A high HPV genotype concordance between stable sexual partners emerged (kappa = 0.92; p probable high-risk HPV cases, 20/23 (86.9 %) low-risk HPV cases and 31/39 (79.5 %) non-genotypeable cases. The high-risk HPV genotypes showed the lowest rate and probability of viral clearance (p < 0.001). In our series, high-risk HPV infections were more likely to persist over time when compared with other HPV genotypes.

  18. Tissue biodistribution and blood clearance rates of intravenously administered carbon nanotube radiotracers

    Science.gov (United States)

    Singh, Ravi; Pantarotto, Davide; Lacerda, Lara; Pastorin, Giorgia; Klumpp, Cédric; Prato, Maurizio; Bianco, Alberto; Kostarelos, Kostas

    2006-02-01

    Carbon nanotubes (CNT) are intensively being developed for biomedical applications including drug and gene delivery. Although all possible clinical applications will require compatibility of CNT with the biological milieu, their in vivo capabilities and limitations have not yet been explored. In this work, water-soluble, single-walled CNT (SWNT) have been functionalized with the chelating molecule diethylentriaminepentaacetic (DTPA) and labeled with indium (111In) for imaging purposes. Intravenous (i.v.) administration of these functionalized SWNT (f-SWNT) followed by radioactivity tracing using gamma scintigraphy indicated that f-SWNT are not retained in any of the reticuloendothelial system organs (liver or spleen) and are rapidly cleared from systemic blood circulation through the renal excretion route. The observed rapid blood clearance and half-life (3 h) of f-SWNT has major implications for all potential clinical uses of CNT. Moreover, urine excretion studies using both f-SWNT and functionalized multiwalled CNT followed by electron microscopy analysis of urine samples revealed that both types of nanotubes were excreted as intact nanotubes. This work describes the pharmacokinetic parameters of i.v. administered functionalized CNT relevant for various therapeutic and diagnostic applications. nanomedicine | blood circulation half-life | drug delivery | pharmacokinetics | nanotoxicology

  19. Validation of the flow-through chamber (FTC and steady-state (SS methods for clearance rate measurements in bivalves

    Directory of Open Access Journals (Sweden)

    Poul S. Larsen

    2011-09-01

    To obtain precise and reliable laboratory clearance rate (filtration rate measurements with the ‘flow-through chamber method’ (FTC the design must ensure that only inflow water reaches the bivalve's inhalant aperture and that exit flow is fully mixed. As earlier recommended these prerequisites can be checked by a plot of clearance rate (CR versus increasing through-flow (Fl to reach a plateau, which is the true CR, but we also recommend to plot percent particles cleared versus reciprocal through-flow where the plateau becomes the straight line CR/Fl, and we emphasize that the percent of particles cleared is in itself neither a criterion for valid CR measurement, nor an indicator of appropriate ‘chamber geometry’ as hitherto adapted in many studies. For the ‘steady-state method’ (SS, the design must ensure that inflow water becomes fully mixed with the bivalve's excurrent flow to establish a uniform chamber concentration prevailing at its incurrent flow and at the chamber outlet. These prerequisites can be checked by a plot of CR versus increasing Fl, which should give the true CR at all through-flows. Theoretically, the experimental uncertainty of CR for a given accuracy of concentration measurements depends on the percent reduction in particle concentration (100×P from inlet to outlet of the ideal ‘chamber geomety’. For FTC, it decreases with increasing values of P while for SS it first decreases but then increases again, suggesting the use of an intermediate value of P. In practice, the optimal value of P may depend on the given ‘chamber geometry’. The fundamental differences between the FTC and the SS methods and practical guidelines for their use are pointed out, and new data on CR for the blue mussel, Mytilus edulis, illustrate a design and use of the SS method which may be employed in e.g. long-term growth experiments at constant algal concentrations.

  20. Study of the capacitance technique for measuring high-temperature blade tip clearance on ceramic rotors

    Science.gov (United States)

    Barranger, John P.

    1993-01-01

    Higher operating temperatures required for increased engine efficiency can be achieved by using ceramic materials for engine components. Ceramic turbine rotors are subject to the same limitations with regard to gas path efficiency as their superalloy predecessors. In this study, a modified frequency-modulation system is proposed for the measurement of blade tip clearance on ceramic rotors. It is expected to operate up to 1370 C (2500 F), the working temperature of present engines with ceramic turbine rotors. The design of the system addresses two special problems associated with nonmetallic blades: the capacitance is less than that of a metal blade and the effects of temperature may introduce uncertainty with regard to the blade tip material composition. To increase capacitance and stabilize the measurement, a small portion of the rotor is modified by the application of 5-micron-thick platinum films. The platinum surfaces on the probe electrodes and rotor that are exposed to the high-velocity gas stream are coated with an additional 10-micron-thick protective ceramic topcoat. A finite-element method is applied to calculate the capacitance as a function of clearance.

  1. High rate drift chambers

    Energy Technology Data Exchange (ETDEWEB)

    Christian, D.C. (Fermilab, Batavia, IL 60510 (United States)); Berisso, M.C. (Fermilab, Batavia, IL 60510 (United States)); Gutierrez, G. (Fermilab, Batavia, IL 60510 (United States)); Holmes, S.D. (Fermilab, Batavia, IL 60510 (United States)); Wehmann, A. (Fermilab, Batavia, IL 60510 (United States)); Avilez, C. (Instituto de Fisica, Universidad de Guanajuato, Leon, Guanajuato (Mexico)); Felix, J. (Instituto de Fisica, Universidad de Guanajuato, Leon, Guanajuato (Mexico)); Moreno, G. (Instituto de Fisica, Universidad de Guanajuato, Leon, Guanajuato (Mexico)); Romero, M. (Instituto de Fisica, Universidad de Guanajuato, Leon, Guanajuato (Mexico)); Sosa, M. (Instituto de Fisica, Universidad de Guanajuato, Leon, Guanajuato (Mexico)); Forbush, M. (Department of Physics, Texas A and M University, College Station, TX 77843 (United States)); Huson, F.R. (Department of Physics, Texas A and M University, College Station, TX 77843 (United States)); Wightman, J.A. (Department of Physi

    1994-06-01

    Fermilab experiment 690, a study of target dissociation reactions pp[yields]pX using an 800 GeV/c proton beam and a liquid hydrogen target, collected data in late 1991. The incident beam and 600-800 GeV/c scattered protons were measured using a system of six 6 in.x4 in. and two 15 in.x8 in. pressurized drift chambers spaced over 260 m. These chambers provided precise measurements at rates above 10 MHz (2 MHz per cm of sense wire). The measurement resolution of the smaller chambers was 90 [mu]m, and the resolution of the larger chambers was 125 [mu]m. Construction details and performance results, including radiation damage, are presented. ((orig.))

  2. Relationship between blood Iactate and lactate clearance rate with prognosis in critical ill patients%危重患者血乳酸水平和清除率与预后的关系

    Institute of Scientific and Technical Information of China (English)

    张朝贵; 杨宗勇; 张春林

    2012-01-01

    Objective To explore the correlation between the prognosis and the blood lactate and lactate clearance rate in critical ill patients. Methods The data of 129 critical ill patients were collected, including blood lactate after admission to ICU, the blood lactate and lactate clearance rate after 6 hours and 12 hours in ICU. A total of 129 cases were divided into survival group and dead group, low lactate clearance rate group and high lactate clearance rate group, and the differences between them were compared for statistical significance. Results There were no differences in age and the initial blood concentration of lactate ( P > 0. 05) ; The lactate clearance rate after 6 hours and 12 hours in survival group was significantly higher than it in dead group [(45. 25 ±12. 52)% VS (8.53 ±11.21)% and (78. 27 ±21. 53)% VS ( - 10. 63 ± 8. 22)% , P 0.05);存活组6h和24h乳酸清除率明显高于死亡组[(45.25±12.52)%VS(8.53±11.21)%和(78.27+21.53)%VS(-10.63±8.22)%,P<0.01];高乳酸清除率组病死率明显低于低乳酸清除率组(20.0%VS 51.0%,P<0.01).结论 血乳酸水平和乳酸清除率是反映危重患者病情严重程度和预后的较好指标.

  3. The clearance concept with special reference to determination of glomerular filtration rate in patients with fluid retention

    DEFF Research Database (Denmark)

    Henriksen, Ulrik L; Henriksen, Jens H

    2014-01-01

    In subjects without fluid retention, the total plasma clearance of a renal filtration indicator (inulin, (99m) Tc-DTPA, (51) Cr-EDTA) is close to the urinary plasma clearance. Conversely, in patients with fluid retention (oedema, pleural effusions, ascites), there is a substantial discrepancy...

  4. High exposure, spontaneous clearance, and low incidence of active Helicobacter pylori infection: the Sorbo San Basile study.

    Science.gov (United States)

    Luzza, Francesco; Suraci, Evelina; Larussa, Tiziana; Leone, Isabella; Imeneo, Maria

    2014-08-01

    A decreased incidence of Helicobacter pylori infection has been prospected to occur nowadays. To evaluate the exposure to H. pylori, prevalence and incidence of active infection, and related risk factors in the general population. In a small town of Southern Italy (932 inhabitants), 595 (3-97 years) and 157 (12-82 years) subjects among those with no evidence of active H. pylori infection participated at baseline and 10 years later, respectively. A questionnaire was administered. Active H. pylori infection was assessed by (13) C-urea breath test (UBT). Serum VacA and CagA antibodies were determined. Of 518 subjects who were evaluated by both UBT and serology, 310 (59.8%) were UBT positive, 479 (92.4%) VacA positive, and 369 (71.2%) CagA positive. Subjects UBT negative and serology positive were 169 (32%), ranging 1 (14.2%) to 29 (82.8%) from last to first decades of life. Age, female gender, and people per room were independent risk factors for subjects UBT positive compared to those UBT negative and serology positive. Ten years later, subjects who became UBT positive were four of 157 (0.25% per year) while those who became seropositive for VacA and/or CagA were 17 of 26 (6.5% per year). H. pylori infection is highly dynamic with wide range of spontaneous clearance. It is easily cleared in the first decades of life, more recent years, less crowded homes, and males. It disappears and recurs more often than it was previously thought, implying that the current decline in its prevalence is due to real clearance instead of a fall in infection rate. © 2014 John Wiley & Sons Ltd.

  5. Malnourished Malawian patients presenting with large Wilms tumours have a decreased vincristine clearance rate

    NARCIS (Netherlands)

    T. Israels; C.W.N. Damen; M. Cole; N. van Geloven; A.V. Boddy; H.N. Caron; J.H. Beijnen; E.M. Molyneux; G.J. Veal

    2010-01-01

    Introduction: In developing countries, patients with a Wilms' tumour often present late with a high degree of malnutrition and large tumours. We investigated whether this affects vincristine pharmacokinetics. Methods: Patients newly diagnosed with Wilms' tumour in Malawi and the UK were included. We

  6. In nondiabetic, human immunodeficiency virus-infected patients with lipodystrophy, hepatic insulin extraction and posthepatic insulin clearance rate are decreased in proportion to insulin resistance

    DEFF Research Database (Denmark)

    Haugaard, Steen B; Andersen, Ove; Hansen, Birgitte R;

    2005-01-01

    In healthy, nondiabetic individuals with insulin resistance, fasting insulin is inversely correlated to the posthepatic insulin clearance rate (MCRi) and the hepatic insulin extraction (HEXi). We investigated whether similar early mechanisms to facilitate glucose homeostasis exist in nondiabetic...... > .1). Our data suggest that HEXi and MCRi are decreased in proportion to the degree of insulin resistance in nondiabetic HIV-infected patients with lipodystrophy....

  7. Determination of drug absorption rate in time-variant disposition by direct deconvolution using beta clearance correction and end-constrained non-parametric regression.

    Science.gov (United States)

    Neelakantan, S; Veng-Pedersen, P

    2005-11-01

    A novel numerical deconvolution method is presented that enables the estimation of drug absorption rates under time-variant disposition conditions. The method involves two components. (1) A disposition decomposition-recomposition (DDR) enabling exact changes in the unit impulse response (UIR) to be constructed based on centrally based clearance changes iteratively determined. (2) A non-parametric, end-constrained cubic spline (ECS) input response function estimated by cross-validation. The proposed DDR-ECS method compensates for disposition changes between the test and the reference administrations by using a "beta" clearance correction based on DDR analysis. The representation of the input response by the ECS method takes into consideration the complex absorption process and also ensures physiologically realistic approximations of the response. The stability of the new method to noisy data was evaluated by comprehensive simulations that considered different UIRs, various input functions, clearance changes and a novel scaling of the input function that includes the "flip-flop" absorption phenomena. The simulated input response was also analysed by two other methods and all three methods were compared for their relative performances. The DDR-ECS method provides better estimation of the input profile under significant clearance changes but tends to overestimate the input when there were only small changes in the clearance.

  8. System-Level Design of a Shape Memory Alloy Actuator for Active Clearance Control in the High-Pressure Turbine

    Science.gov (United States)

    DeCastro, Jonathan A.; Melcher, Kevin J.; Noebe, Ronald D.

    2005-01-01

    This paper describes results of a numerical analysis evaluating the feasibility of high-temperature shape memory alloys (HTSMA) for active clearance control actuation in the high-pressure turbine section of a modern turbofan engine. The prototype actuator concept considered here consists of parallel HTSMA wires attached to the shroud that is located on the exterior of the turbine case. A transient model of an HTSMA actuator was used to evaluate active clearance control at various operating points in a test bed aircraft engine simulation. For the engine under consideration, each actuator must be designed to counteract loads from 380 to 2000 lbf and displace at least 0.033 inches. Design results show that an actuator comprised of 10 wires 2 inches in length is adequate for control at critical engine operating points and still exhibits acceptable failsafe operability and cycle life. A proportional-integral-derivative (PID) controller with integrator windup protection was implemented to control clearance amidst engine transients during a normal mission. Simulation results show that the control system exhibits minimal variability in clearance control performance across the operating envelope. The final actuator design is sufficiently small to fit within the limited space outside the high-pressure turbine case and is shown to consume only small amounts of bleed air to adequately regulate temperature.

  9. Duplication of CYP2D6 predicts high clearance of desipramine but high clearance does not predict duplication of CYP2D6

    DEFF Research Database (Denmark)

    Bergmann, T K; Bathum, L; Brøsen, Kim

    2001-01-01

    a duplicated allele. The question is whether gene duplication is a relatively rare cause (perhaps predictor) of very rapid metabolism or whether a low metabolic ratio is a poor predictor of this. METHODS: After measuring metabolic ratios anew, we selected six volunteers with duplication of CYP2D6 and metabolic...... ratios ranging from 0.07 to 0.17 and six volunteers without duplication with metabolic ratios ranging from 0.08 to 0.21. Each subject took 100 mg of desipramine. Blood and urine were collected for 48 h. RESULTS: The median total oral clearance of desipramine was 372 l/h and 196 l/h [median difference 108...... l/h (95.9% c.i., -304-598 l/h)] and the median partial clearance of desipramine by 2-hydroxylation was 155 l/h and 87 l/h [median difference 47 l/h (95.9% c.i., -124-141 l/h)] for the group with duplication and the group without duplication, respectively. CONCLUSION: The predictive value...

  10. 24-hour creatinine clearance reliability for estimation of glomerular filtration rate in different stages of chronic kidney disease

    Directory of Open Access Journals (Sweden)

    El-Minshawy Osama

    2010-01-01

    Full Text Available Glomerular Filtration Rate (GFR is considered the best overall index of renal function currently used. Measurement of 24 hours urine/plasma creatinine ratio (UV/P is usually used for estimation of GFR. However little is known about its accuracy in different stages of Chronic Kidney Disease (CKD aim: is to evaluate performance of UV/P in classification of CKD by comparing it with isotopic GFR (iGFR. 136 patients with CKD were enrolled in this study 80 (59% were males, 48 (35% were diabetics. Mean age 46 ± 13. Creatinine Clearance (Cr.Cl estimated by UV/P and Cockroft-Gault (CG was done for all patients, iGFR was the reference value. Accuracy of UV/P was 10%, 31%, 49% within ± 10%, ± 30%, ± 50% error respectively, r 2 = 0.44. CG gave a better performance even when we restrict our analysis to diabetics only, the accuracy of CG was 19%, 47%, 72% in ± 10%, ± 30% and ± 50% errors respectively, r 2 = 0.63. Both equations gave poor classification of CKD. In conclusion, UV/P has poor accuracy in estimation of GFR, The accuracy worsened as kidney disease becomes more severe. We conclude 24 hours CrCl. is not good substitute for measurement of GFR in patients with CKD.

  11. High-frequency chest compression system to aid in clearance of mucus from the lung.

    Science.gov (United States)

    Hansen, L G; Warwick, W J

    1990-01-01

    The authors developed a high-frequency chest compression (HFCC) device to aid in mucous clearance for patients with obstructive lung disease. The device, designed for self-therapy, consists of a large-volume variable-frequency air-pulse delivery system and a nonstretchable inflatable vest worn by the patient. Pressure pulses are controlled by the patient and applied during expiration. Pulse frequency is tunable from 5 to 25 Hz. Maximum vest pressure is 39 mmHg (5.2 kPa), with patient-controlled vest inflation and deflation time constants of 0.5 s. Vest pressure increases from 28 mmHg (3.7 kPa) at 5 Hz to 39 mmHg (5.2 kPa) at 25 Hz. Preliminary clinical trials have shown the HFCC device to be more effective than standard chest physical therapy. The HFCC device yielded a mean volume of cleared mucus of 3.3 cc per session, compared with 1.8 cc for a conventional therapy session.

  12. A High Throughput, 384-Well, Semi-Automated, Hepatocyte Intrinsic Clearance Assay for Screening New Molecular Entities in Drug Discovery.

    Science.gov (United States)

    Heinle, Lance; Peterkin, Vincent; de Morais, Sonia M; Jenkins, Gary J; Badagnani, Ilaria

    2015-01-01

    A high throughput, semi-automated clearance screening assay in hepatocytes was developed allowing a scientist to generate data for 96 compounds in one week. The 384-well format assay utilizes a Thermo Multidrop Combi and an optimized LC-MS/MS method. The previously reported LCMS/ MS method reduced the analytical run time by 3-fold, down to 1.2 min injection-to-injection. The Multidrop was able to deliver hepatocytes to 384-well plates with minimal viability loss. Comparison of results from the new 384-well and historical 24-well assays yielded a correlation of 0.95. In addition, results obtained for 25 marketed drugs with various metabolism pathways had a correlation of 0.75 when compared with literature values. Precision was maintained in the new format as 8 compounds tested in ≥39 independent experiments had coefficients of variation ≤21%. The ability to predict in vivo clearances using the new stability assay format was also investigated using 22 marketed drugs and 26 AbbVie compounds. Correction of intrinsic clearance values with binding to hepatocytes (in vitro data) and plasma (in vivo data) resulted in a higher in vitro to in vivo correlation when comparing 22 marketed compounds in human (0.80 vs 0.35) and 26 AbbVie Discovery compounds in rat (0.56 vs 0.17), demonstrating the importance of correcting for binding in clearance studies. This newly developed high throughput, semi-automated clearance assay allows for rapid screening of Discovery compounds to enable Structure Activity Relationship (SAR) analysis based on high quality hepatocyte stability data in sufficient quantity and quality to drive the next round of compound synthesis.

  13. High creatinine clearance in critically ill patients with community-acquired acute infectious meningitis

    Directory of Open Access Journals (Sweden)

    Lautrette Alexandre

    2012-09-01

    Full Text Available Abstract Background A high dose of anti-infective agents is recommended when treating infectious meningitis. High creatinine clearance (CrCl may affect the pharmacokinetic / pharmacodynamic relationships of anti-infective drugs eliminated by the kidneys. We recorded the incidence of high CrCl in intensive care unit (ICU patients admitted with meningitis and assessed the diagnostic accuracy of two common methods used to identify high CrCl. Methods Observational study performed in consecutive patients admitted with community-acquired acute infectious meningitis (defined by >7 white blood cells/mm3 in cerebral spinal fluid between January 2006 and December 2009 to one medical ICU. During the first 7 days following ICU admission, CrCl was measured from 24-hr urine samples (24-hr-UV/P creatinine and estimated according to Cockcroft-Gault formula and the simplified Modification of Diet in Renal Disease (MDRD equation. High CrCl was defined as CrCl >140 ml/min/1.73 m2 by 24-hr-UV/P creatinine. Diagnostic accuracy was performed with ROC curves analysis. Results Thirty two patients were included. High CrCl was present in 8 patients (25% on ICU admission and in 15 patients (47% during the first 7 ICU days for a median duration of 3 (1-4 days. For the Cockcroft-Gault formula, the best threshold to predict high CrCl was 101 ml/min/1.73 m2 (sensitivity: 0.96, specificity: 0.75, AUC = 0.90 ± 0.03 with a negative likelihood ratio of 0.06. For the simplified MDRD equation, the best threshold to predict high CrCl was 108 ml/min/1.73 m2 (sensitivity: 0.91, specificity: 0.80, AUC = 0.88 ± 0.03 with a negative likelihood ratio of 0.11. There was no difference between the estimated methods in the diagnostic accuracy of identifying high CrCl (p = 0.30. Conclusions High CrCl is frequently observed in ICU patients admitted with community-acquired acute infectious meningitis. The estimated methods of CrCl could be used as a screening tool to

  14. Anal human papillomavirus in HIV-uninfected men who have sex with men: incidence and clearance rates, duration of infection, and risk factors.

    Science.gov (United States)

    Donà, M G; Vescio, M F; Latini, A; Giglio, A; Moretto, D; Frasca, M; Benevolo, M; Rollo, F; Colafigli, M; Cristaudo, A; Giuliani, M

    2016-12-01

    Little is known regarding the natural history of anal human papillomavirus (HPV) infection. We aimed to evaluate incidence and clearance rates, their risk factors, and duration of anal HPV infection in HIV-uninfected men who have sex with men (MSM). A longitudinal study was conducted. Anal samples were analysed using the Linear Array HPV Genotyping test. Incidence and clearance rates, and corresponding risk factors, were estimated using a two-state Markov model. Overall, 155 MSM (median age 33.4 years) attending the largest sexually transmitted infection (STI) centre in Rome, Italy, were followed for a median of 12.2 months (Q1-Q3: 7.0-18.1). Incidence and clearance rates for any HPV were 85.6 (95% CI: 58.4-125.4) and 35.6 (95% CI: 24.7-51.5) × 1000 person-months, respectively; the median duration of infection was 9.4 months (Q1-Q3: 7.5-12.1). Receptive anal sex emerged as the only risk factor for the acquisition of any HPV (Hazard Ratio, HR = 2.65, 95% CI: 1.16-6.06). The incidence rates for carcinogenic and non-carcinogenic types were 42.3 (95% CI: 29.2-61.4) and 29.2 (95% CI: 19.5-43.7) × 1000 person-months, respectively (p = 0.13); their clearance rates were 62.9 (95% CI: 45.1-87.7) and 65.7 (95% CI: 47.4-91.0) × 1000 person-months, respectively (p = 0.83). HPV16 showed the lowest clearance rate among carcinogenic types (59.7 × 1000 person-months), and a duration of infection of 16.8 months. In conclusion, a higher incidence rate was observed for carcinogenic compared to non-carcinogenic HPV types, although the difference was not significant. HPV16 emerged as the type with the longest duration of infection and the lowest clearance rate among carcinogenic types.

  15. Primed-infusion technique for rapid estimation of the metabolic clearance rate of 1,25(OH)/sub 2/D/sub 3/

    Energy Technology Data Exchange (ETDEWEB)

    Eastell, R.; Riggs, B.L.; Kumar, R.

    1987-09-01

    The authors have developed a rapid primed-infusion technique for the measurement of the metabolic clearance and production rate of 1,25-dihydroxyvitamin D/sub 3/ in normal human subjects and experimental animals. With this method, an estimate of the metabolic clearance rate of 1,25-dihydroxyvitamin D/sub 3/ can generally be made within 3 to 4 h. Initial studies in five dogs using 1,25-(/sup 3/H)-dihydroxyvitamin D/sub 3/ allowed us to determine the optimal ratio of loading dose to infusion rate that resulted in the most rapid attainment of steady-state levels of plasma radioactivity. By use of this technique they found that the metabolic clearance rate of 1,25-dihydroxyvitamin D/sub 3/ in dogs was 6.3 +/- 1.2 ml/min; the production rate of the hormone was 0.40 +/- 0.25 ..mu..g/day. In eight normal women, aged 28-51 yr, the metabolic clearance rate for 1,25-dihydroxyvitamin D/sub 3/ was 25.9 +/- 4.7 ml/min; the production rate was 1.38 +/- 0.45 ..mu..g/day. The advantages of this method relative to ones used in the past are that it can be performed quickly (generally within 3-4 h) with the use of only tracer amounts of this hormone (equivalent to 1.1% of the production rate). With this method, no assumptions about the most appropriate model to which to fit the data need to be made. Because of its rapidity, no metabolites of the injected 1,25-dihydroxyvitamin D/sub 3/ are formed during the study interval.

  16. Thermal dependence of clearance and metabolic rates in slow- and fast-growing spats of manila clam Ruditapes philippinarum.

    Science.gov (United States)

    Tamayo, David; Ibarrola, Irrintzi; Navarro, Enrique

    2013-10-01

    Thermal dependence of clearance rate (CR: l h(-1)), standard (SMR: J h(-1)) and routine metabolic rates (RMR: J h(-1)), were analyzed in fast (F)- and slow (S)-growing juveniles of the clam Ruditapes philippinarum. Physiological rates were measured at the maintenance temperature (17 °C), and compared with measurements performed at 10 and 24 °C after 16 h and 14 days to analyze acute and acclimated responses, respectively. Metabolic rates (both RMR and SMR) differed significantly between F and S seeds, irrespective of temperature. Mass-specific CRs were not different for F and S seeds but were significantly higher in F clams for rates standardized according to allometric size-scaling rules. Acute thermal dependency of CR was equal for F and S clams: mean Q 10 were ≈3 and 2 in temperature ranges of 10-17 and 17-24 °C, respectively. CR did not change after 2 weeks of acclimation to temperatures. Acute thermal effects on SMR were similar in both groups (Q 10 ≈ 1 and 1.6 in temperature ranges of 10-17 and 17-24 °C, respectively). Large differences between groups were found in the acute thermal dependence of RMR: Q 10 in F clams (≈1.2 and 1.9 at temperature ranges of 10-17 and 17-24 °C, respectively) were similar to those found for SMR (Q 10 = 1.0 and 1.7). In contrast, RMR of S clams exhibited maximum thermal dependence (Q 10 = 3.1) at 10-17 °C and become depressed at higher temperatures (Q 10 = 0.9 at 17-24 °C). A recovery of RMR in S clams was recorded upon acclimation to 24 °C. Contrasting metabolic patterns between fast and slow growers are interpreted as a consequence of differential thermal sensitivity of the fraction of metabolism associated to food processing and assimilation.

  17. Effects of Changes in Lung Volume on Oscillatory Flow Rate During High-Frequency Chest Wall Oscillation

    Directory of Open Access Journals (Sweden)

    Scott J Butcher

    2007-01-01

    Full Text Available BACKGROUND: The effectiveness of high-frequency chest wall oscillation (HFCWO in mucolysis and mucous clearance is thought to be dependant on oscillatory flow rate (Fosc. Therefore, increasing Fosc during HFCWO may have a clinical benefit.

  18. Estimated Glomerular Filtration Rate Correlates Poorly with Four-Hour Creatinine Clearance in Critically Ill Patients with Acute Kidney Injury

    Directory of Open Access Journals (Sweden)

    Christopher J. Kirwan

    2013-01-01

    Full Text Available Introduction. RIFLE and AKIN provide a standardised classification of acute kidney injury (AKI, but their categorical rather than continuous nature restricts their use to a research tool. A more accurate real-time description of renal function in AKI is needed, and some published data suggest that equations based on serum creatinine that estimate glomerular filtration rate (eGFR can provide this. In addition, incorporating serum cystatin C concentration into estimates of GFR may improve their accuracy, but no eGFR equations are validated in critically ill patients with AKI. Aim. This study tests whether creatinine or cystatin-C-based eGFR equations, used in patients with CKD, offer an accurate representation of 4-hour creatinine clearance (4CrCl in critically ill patients with AKI. Methods. Fifty-one critically ill patients with AKI were recruited. Thirty-seven met inclusion criteria, and the performance of eGFR equations was compared to 4CrCl. Results. eGFR equations were better than creatinine alone at predicting 4CrCl. Adding cystatin C to estimates did not improve the bias or add accuracy. The MDRD 7 eGFR had the best combination of correlation, bias, percentage error and accuracy. None were near acceptable standards quoted in patients with chronic kidney disease (CKD. Conclusions. eGFR equations are not sufficiently accurate for use in critically ill patients with AKI. Incorporating serum cystatin C does not improve estimates. eGFR should not be used to describe renal function in patients with AKI. Standards of accuracy for validating eGFR need to be set.

  19. Hypoalbuminemia is significantly associated with increased clearance time of high dose methotrexate in patients being treated for lymphoma or leukemia.

    Science.gov (United States)

    Reiss, Samantha N; Buie, Larry W; Adel, Nelly; Goldman, Debra A; Devlin, Sean M; Douer, Dan

    2016-12-01

    As a weak acid, methotrexate (MTX) is bound to serum albumin and has variable protein binding. The purpose of this study was to assess serum albumin's relationship with MTX pharmacokinetics by comparing MTX clearance and toxicities between patients with normal serum albumin to those with hypoalbuminemia. This single-center retrospective study included adult patients with leukemia or lymphoma who received their first MTX at a dose ≥1 g/m(2). Hypoalbuminemia was defined as serum albumin ≤3.4 g/dL. MTX clearance was defined as the first documented time the MTX level ≤0.05 μM. Fisher's exact tests and Wilcoxon rank sum tests were used to examine differences in toxicities, and Cox proportional hazard regression was used to assess relationship with time to clearance. Of 523 patients identified, 167 patients were evaluable. One hundred thirty-five patients had normal serum albumin and 32 had hypoalbuminemia. Hypoalbuminemia was associated with a higher proportion of patients experiencing edema, ascites or pleural effusions (34 vs. 12 %, p = 0.006), and the concomitant use of nephrotoxic agents (41 vs. 20 %, p = 0.021). Hypoalbuminemia was associated with a significantly longer time to MTX clearance (median 96 vs. 72 h, p = 0.004). In addition, patients with hypoalbuminemia had a higher proportion of hyperbilirubinemia and significantly longer hospitalization (median 14 vs. 5 days, p clearance and increased length of hospitalization. High dose MTX is safe to administer in patients with low albumin levels, with appropriate leucovorin rescue, and good supportive care.

  20. Filtration and clearance rates of Anadara grandis juveniles (Pelecypoda, Arcidae with different temperatures and suspended matter concentrations

    Directory of Open Access Journals (Sweden)

    Anselmo Miranda-Baeza

    2006-09-01

    Full Text Available The mangrove cockle Anadara grandis (Broderip and Sowerby, 1829 is a potential candidate for aquaculture and for bioremediation of aquaculture effluents in the tropical and subtropical coastal areas of the eastern Pacific Ocean. Laboratory-produced spat are available, but there is no information on their responses to the range of environmental conditions to which they might be subject during the growth cycle. The aim of this study was to evaluate the filtration and clearance rates of A. grandis spat (shell length 9.50±0.37 mm with a food concentration (7.5 mg∙l-1 at four different temperatures (22, 25, 28 and 31 ºC, with pH = 7.5±0.2 and O2 concentration of 6.4±0.5 mg·l-1; experiment one; and with a temperature (25 °C and five concentrations of suspended matter (from 7.5 to 29 mg·l-1 and pH and O2 values of 7.9±0.2 and 6.8± 0.4 mg·l-1; experiment two. Filtration and clearance rates were highest at 25 ºC and significantly different (p.05. In the second experiment filtration increased according to the amount of food available, but there were no significant differences (p>.05 between 7.5 and 11 mg·l-1 and from 22.4 to 29 mg·l-1. The trend was similar for clearance, and in this case significant differences were found (pLa almeja Anadara grandis (Broderip and Sowerby, 1829 es un candidato potencial para la acuicultura y la biorremediación de efluentes acuícolas en las áreas costeras tropicales y subtropicales del océano Pacífico oriental. Se dispone de semilla producida en laboratorio, sin embargo no hay información sobre sus respuestas a los intervalos de las condiciones ambientales a las cuales puede estar sujeta durante el periodo de crecimiento. El objetivo de este estudio fue evaluar las tasas de filtración y de clarificación de semilla de A. grandis (largo de la concha= 9.50±0.37 mm con una concentración de alimento (7.5 mg∙l-1 y cuatro diferentes temperaturas (22, 25, 28 y 31 °C con pH= 7.5±0.2, concentración de O

  1. Predicting Clearance Mechanism in Drug Discovery: Extended Clearance Classification System (ECCS).

    Science.gov (United States)

    Varma, Manthena V; Steyn, Stefanus J; Allerton, Charlotte; El-Kattan, Ayman F

    2015-12-01

    Early prediction of clearance mechanisms allows for the rapid progression of drug discovery and development programs, and facilitates risk assessment of the pharmacokinetic variability associated with drug interactions and pharmacogenomics. Here we propose a scientific framework--Extended Clearance Classification System (ECCS)--which can be used to predict the predominant clearance mechanism (rate-determining process) based on physicochemical properties and passive membrane permeability. Compounds are classified as: Class 1A--metabolism as primary systemic clearance mechanism (high permeability acids/zwitterions with molecular weight (MW) ≤400 Da), Class 1B--transporter-mediated hepatic uptake as primary systemic clearance mechanism (high permeability acids/zwitterions with MW >400 Da), Class 2--metabolism as primary clearance mechanism (high permeability bases/neutrals), Class 3A--renal clearance (low permeability acids/zwitterions with MW ≤400 Da), Class 3B--transporter mediated hepatic uptake or renal clearance (low permeability acids/zwitterions with MW >400 Da), and Class 4--renal clearance (low permeability bases/neutrals). The performance of the ECCS framework was validated using 307 compounds with single clearance mechanism contributing to ≥70% of systemic clearance. The apparent permeability across clonal cell line of Madin - Darby canine kidney cells, selected for low endogenous efflux transporter expression, with a cut-off of 5 × 10(-6) cm/s was used for permeability classification, and the ionization (at pH7) was assigned based on calculated pKa. The proposed scheme correctly predicted the rate-determining clearance mechanism to be either metabolism, hepatic uptake or renal for ~92% of total compounds. We discuss the general characteristics of each ECCS class, as well as compare and contrast the framework with the biopharmaceutics classification system (BCS) and the biopharmaceutics drug disposition classification system (BDDCS

  2. Estimating glomerular filtration rate in oncology patients receiving Cisplatin chemotherapy: Predicted creatinine clearance against 99mTc-DTPA methods

    Science.gov (United States)

    Khaidah Syed Sahab, Sharifah; Manap, Mahayuddin; Hamzah, Fadzilah

    2017-05-01

    The therapeutic potential of cisplatin as the best anticancer treatment for solid tumor is limited by its potential nephrotoxicity. This study analyses the incidence of cisplatin induced nephrotoxicity in oncology patients through GFR estimation using 99mTc-DTPA plasma sampling (reference method) and to compare with predicted creatinine clearance and Tc-99m renal scintigraphy. A prospective study of 33 oncology patients referred for GFR estimation in Penang Hospital. The incidence of cisplatin induced nephrotoxicity was analysed via radionuclide and creatinine based method. Of 33 samples, only 21 selected for the study. The dose of cisplatin given was 75 mg/m2 for each cycle. The mean difference of GFR pre and post chemotherapy (PSC 2) was 13.38 (-4.60, 31.36) ml/min/1.73m2 (p 0.136). Of 21 patients, 3 developed severe nephrotoxicity (GFR < 50ml/min/1.73 m2) contributing 14.3% of incidence. Bland-Altman plot showed only PSC 1 is in agreement with PSC 2 technique. Intraclass Correlation Coefficients (ICC) also showed that PSC 1 has high degree of reliability in comparison to PSC 2 (p < 0.001). The other methods do not show reliability and agreement in comparison to PSC 2 (p < 0.05). 3 of 21 patients (14.3%) developed severe nephrotoxicity post cisplatin chemotherapy. This percentage is much less than the reported 20 - 25% of cases from other studies, probably due to small sample size and biased study population due to strict exclusion criteria. Radionuclide method for evaluating GFR is the most sensitive method for the detection of cisplatin induced nephrotoxicity by showing 3 of 21 patients developing severe nephrotoxicity. PSC 1 was found to be a reliable substitute of PSC 2. The other methods are not reliable for detection of early nephrotoxicity. We will recommend the use of single plasma sampling method (PSC 1) for GFR estimation in monitoring post cisplatin chemotherapy patients.

  3. Design analysis and development of a high temperature actuaror for gas turbine blade tip clearance control

    OpenAIRE

    2011-01-01

    During a typical startup cycle industrial gas turbine blades experience rapid radial thermal expansion while bulky shroud structure with larger thermal inertia requires much longer period to reach its operating temperature. Turbine designers have to leave a safe radial distance in order to prevent contact of blades to the surrounding annular casing. However, when thermal steady state in the turbine stage is achieved, shroud and casing grow and excessive amount of blade-shroud clearance remain...

  4. The relationship between the early lactate clearance rate and the prognosis of patients with severe sepsis and septic shock%早期乳酸清除率对严重脓毒症和脓毒性休克预后的影响

    Institute of Scientific and Technical Information of China (English)

    张亮

    2016-01-01

    Objective:To discuss the effects of early lactate clearance rate on the prognosis of patients with severe sepsis and septic shock. Methods:The lactic acid levels in 112 patients with severe sepsis and septic shock were measured at admission and at 6 hours of admission,and the lactate clearance rates of all cases were calculated. All patients were divided into the high lactate clearance rate group( the lactate clearance rate more than 10%) and low lactate clearance rate group( the lactate clearance rate less than 10%) . The mortality,initial level of lactic acid and APACHE Ⅱ score between two groups were compared. All patients were followed up for 30 days,and divided into the survival group and death group according to their survival. The arterial blood lactate level, early lactate clearance rate and APACHE Ⅱ score between two groups were compared. Results:The difference of the initial level of lactic acid between the high lactate clearance rate group and low lactate clearance rate group was statistically significant(P10%)组和低乳酸清除率(乳酸清除率≤10%)组,比较2组病死率、初始乳酸水平和APACHEⅡ评分.随访30 d,根据患者生存情况将患者分为存活组和死亡组,比较2组动脉血乳酸水平、早期乳酸清除率及APACHEⅡ评分.结果:高乳酸清除率组和低乳酸清除率组初始乳酸水平差异有统计学意义(P<0.01).高乳酸清除率组病死率和APACHEⅡ评分均明显低于低乳酸清除率组(P<0.01),随访30 d后,病死45例,存活67例,存活组APACHEⅡ评分明显低于病死组(P<0.01).存活组早期乳酸清除率明显高于病死组(P<0.01).结论:早期乳酸清除率可以作为判断严重脓毒症及脓毒性休克患者预后的一个重要指标.

  5. High Data Rate Quantum Cryptography

    Science.gov (United States)

    Kwiat, Paul; Christensen, Bradley; McCusker, Kevin; Kumor, Daniel; Gauthier, Daniel

    2015-05-01

    While quantum key distribution (QKD) systems are now commercially available, the data rate is a limiting factor for some desired applications (e.g., secure video transmission). Most QKD systems receive at most a single random bit per detection event, causing the data rate to be limited by the saturation of the single-photon detectors. Recent experiments have begun to explore using larger degree of freedoms, i.e., temporal or spatial qubits, to optimize the data rate. Here, we continue this exploration using entanglement in multiple degrees of freedom. That is, we use simultaneous temporal and polarization entanglement to reach up to 8.3 bits of randomness per coincident detection. Due to current technology, we are unable to fully secure the temporal degree of freedom against all possible future attacks; however, by assuming a technologically-limited eavesdropper, we are able to obtain 23.4 MB/s secure key rate across an optical table, after error reconciliation and privacy amplification. In this talk, we will describe our high-rate QKD experiment, with a short discussion on our work towards extending this system to ship-to-ship and ship-to-shore communication, aiming to secure the temporal degree of freedom and to implement a 30-km free-space link over a marine environment.

  6. Estimating kidney function in HIV-infected adults in Kenya: comparison to a direct measure of glomerular filtration rate by iohexol clearance.

    Directory of Open Access Journals (Sweden)

    Christina M Wyatt

    Full Text Available BACKGROUND: More than two-thirds of the world's HIV-positive individuals live in sub-Saharan Africa, where genetic susceptibility to kidney disease is high and resources for kidney disease screening and antiretroviral therapy (ART toxicity monitoring are limited. Equations to estimate glomerular filtration rate (GFR from serum creatinine were derived in Western populations and may be less accurate in this population. METHODS: We compared results from published GFR estimating equations with a direct measure of GFR by iohexol clearance in 99 HIV-infected, ART-naïve Kenyan adults. Iohexol concentration was measured from dried blood spots on filter paper. The bias ratio (mean of the ratio of estimated to measured GFR and accuracy (percentage of estimates within 30% of the measured GFR were calculated. RESULTS: The median age was 35 years, and 60% were women. The majority had asymptomatic HIV, with median CD4+ cell count of 355 cells/mm(3. Median measured GFR was 115 mL/min/1.73 m(2. Overall accuracy was highest for the Chronic Kidney Disease Epidemiology Consortium (CKD-EPI equation. Consistent with a prior report, bias and accuracy were improved by eliminating the coefficient for black race (85% of estimates within 30% of measured GFR. Accuracy of all equations was poor in participants with GFR 60-90 mL/min/1.73 m(2 (<65% of estimates within 30% of measured GFR, although this subgroup was too small to reach definitive conclusions. CONCLUSIONS: Overall accuracy was highest for the CKD-EPI equation. Eliminating the coefficient for race further improved performance. Future studies are needed to determine the most accurate GFR estimate for use in individuals with GFR <90 mL/min/1.73 m(2, in whom accurate estimation of kidney function is important to guide drug dosing. Direct measurement of GFR by iohexol clearance using a filter paper based assay is feasible for research purposes in resource-limited settings, and could be used to develop more accurate

  7. Noninvasive clearance of airway secretions.

    Science.gov (United States)

    Hardy, K A; Anderson, B D

    1996-06-01

    Airway clearance techniques are indicated for specific diseases that have known clearance abnormalities (Table 2). Murray and others have commented that such techniques are required only for patients with a daily sputum production of greater than 30 mL. The authors have observed that patients with diseases known to cause clearance abnormalities can have sputum clearance with some techniques, such as positive expiratory pressure, autogenic drainage, and active cycle of breathing techniques, when PDPV has not been effective. Hasani et al has shown that use of the forced exhalatory technique in patients with nonproductive cough still resulted in movement of secretions proximally from all regions of the lung in patients with airway obstruction. It is therefore reasonable to consider airway clearance techniques for any patient who has a disease known to alter mucous clearance, including CF, dyskinetic cilia syndromes, and bronchiectasis from any cause. Patients with atelectasis from mucous plugs and hypersecretory states, such as asthma and chronic bronchitis, patients with pain secondary to surgical procedures, and patients with neuromuscular disease, weak cough, and abnormal patency of the airway may also benefit from the application of airway clearance techniques. Infants and children up to 3 years of age with airway clearance problems need to be treated with PDPV. Manual percussion with hands alone or a flexible face mask or cup and small mechanical vibrator/percussors, such as the ultrasonic devices, can be used. The intrapulmonary percussive ventilator shows growing promise in this area. The high-frequency oscillator is not supplied with vests of appropriate sizes for tiny babies and has not been studied in this group. Young patients with neuromuscular disease may require assisted ventilation and airway oscillations can be applied. CPAP alone has been shown to improve achievable flow rates that will increase air-liquid interactions for patients with these diseases

  8. Short-term comparative study of high frequency chest wall oscillation and European airway clearance techniques in patients with cystic fibrosis

    OpenAIRE

    Osman, Leyla P; Roughton, Michael; Hodson, Margaret E; Pryor, Jennifer A

    2009-01-01

    Background High frequency chest wall oscillation (HFCWO) is standard treatment for airway clearance in the USA and has recently been introduced in the UK and Europe. There is little published research comparing HFCWO with airway clearance techniques (ACTs) frequently used in the UK and Europe. The aim of this study was to compare the short-term effects of HFCWO with usual ACTs in patients with cystic fibrosis hospitalised with an infective pulmonary exacerbation. Methods A 4-day randomised cr...

  9. Accuracy of GFR estimation formula in determination of glomerular filtration rate in kidney donors: Comparison with 24 h urine creatinine clearance

    Directory of Open Access Journals (Sweden)

    Abdul Rauf Hafeez

    2016-01-01

    Full Text Available To determine the accuracy of estimated glomerular filtration rate (eGFR using the modification of diet in renal disease (MDRD, Cockcroft-Gault (CG, and chronic kidney disease epidemiology (CKD-EPI formulas in potential kidney donors compared with 24-h urine creatinine clearance, we studied 207 potential live kidney donors in our center. There were 126 (60.9% males and 81 (39.1% females. Male:female ratio was 1.6:1. The age of the donors ranged from 18-58 years, with mean age of 35.30 ± 9.23 years and most of the individuals were below 40 years of age. The body mass index (BMI was calculated and venous blood samples were obtained for the measurement of serum creatinine and every study participant was instructed to collect 24-h urine. GFR was calculated based on 24-h urine creatinine clearance and the formulas. The accuracy of GFR estimation formula was taken as positive if the GFR calculated by the formulas and urine creatinine clearance fell between 90-120 mL/min/1.73 m 2 . The accuracy of the MDRD formula was 48.8% and the CG formula was 41.5% whereas the accuracy of the CKD-EPI formula was 78.2%. The accuracy of the eGFR using the MDRD formula was significantly higher in males than females (57.9% vs. 33.3% P = 0.001, while there was no statistically significant difference in the eGFR between them in case of the use of the CG and the CKD-EPI formulas. BMI and obesity had no effect on the accuracy of eGFR by the use of the different formulas. The performance of GFR estimation formulas was sub optimal and these either underestimated and/or over-estimated the GFR in healthy subjects. CKD-EPI is closer to 24 -h urinary creatinine clearance in the calculation of eGFR. However, none of the eGFR formulas can be used in renal transplant donors because of their low accuracy, and 24-h urine creatinine clearance should be used for evaluation of the GFR in this population.

  10. Accuracy of GFR estimation formula in determination of glomerular filtration rate in kidney donors: Comparison with 24 h urine creatinine clearance.

    Science.gov (United States)

    Hafeez, Abdul Rauf; Idrees, Muhammad Khalid; Akhtar, Syed Fazal

    2016-03-01

    To determine the accuracy of estimated glomerular filtration rate (eGFR) using the modification of diet in renal disease (MDRD), Cockcroft-Gault (CG), and chronic kidney disease epidemiology (CKD-EPI) formulas in potential kidney donors compared with 24-h urine creatinine clearance, we studied 207 potential live kidney donors in our center. There were 126 (60.9%) males and 81 (39.1%) females. Male:female ratio was 1.6:1. The age of the donors ranged from 18-58 years, with mean age of 35.30 ± 9.23 years and most of the individuals were below 40 years of age. The body mass index (BMI) was calculated and venous blood samples were obtained for the measurement of serum creatinine and every study participant was instructed to collect 24-h urine. GFR was calculated based on 24-h urine creatinine clearance and the formulas. The accuracy of GFR estimation formula was taken as positive if the GFR calculated by the formulas and urine creatinine clearance fell between 90-120 mL/min/1.73 m(2). The accuracy of the MDRD formula was 48.8% and the CG formula was 41.5% whereas the accuracy of the CKD-EPI formula was 78.2%. The accuracy of the eGFR using the MDRD formula was significantly higher in males than females (57.9% vs. 33.3% P = 0.001), while there was no statistically significant difference in the eGFR between them in case of the use of the CG and the CKD-EPI formulas. BMI and obesity had no effect on the accuracy of eGFR by the use of the different formulas. The performance of GFR estimation formulas was sub optimal and these either underestimated and/or over-estimated the GFR in healthy subjects. CKD-EPI is closer to 24 -h urinary creatinine clearance in the calculation of eGFR. However, none of the eGFR formulas can be used in renal transplant donors because of their low accuracy, and 24-h urine creatinine clearance should be used for evaluation of the GFR in this population.

  11. Heterogeneity of rat FSH by chromatofocusing: studies on serum FSH, hormone released in vitro and metabolic clearance rates of its various forms.

    Science.gov (United States)

    Blum, W F; Gupta, D

    1985-04-01

    Rat pituitary FSH was fractionated by chromatofocusing between pH 6 and 3. Ten components were resolved having apparent isoelectric points between 3.1 and 5.1. A comparative study of pituitary FSH and FSH secreted in vitro by quartered pituitary glands in the presence and in the absence of gonadotrophin-releasing hormone (GnRH) revealed similar patterns of charged species of intracellular and released FSH. Although GnRH increased FSH secretion about fourfold, no influence on the pattern of charged species was observed. Utilizing exclusion chromatography and chromatofocusing, pituitary FSH was compared to serum FSH which had been extracted by immuno-affinity chromatography. The results demonstrate for serum FSH a larger molecular size and a relative shift to more acidic components. Metabolic clearance rates of eight FSH components separated by chromatofocusing were measured in adult male rats. Half-lives varied between 13 min and several hours. A correlation existed between decrease of isoelectric points and decrease of metabolic clearance rates. These findings suggest that all hypophysial FSH components are secreted into the circulation at similar rates and the more acidic FSH components which appear to contain increased sialic acid, have a longer circulatory half-life and are more abundant in serum. It is concluded that sialylation may be involved in modulating serum FSH levels.

  12. Effect of clearance on wrinkling of 21-6-9 high-strength stainless steel tubes in numerical control rotary draw bending process

    Science.gov (United States)

    Cheng, Lu; Fang, Jun; Li, Yuan; Dai, Li; Xiong, Mengsi; Lu, Shiqiang

    2017-03-01

    Clearance between tube and all kinds of dies has a significant and complicated influence on wrinkling of 21-6-9 high-strength stainless steel tubes (HSST) during numerical control (NC) rotary draw bending process. To explore the effect of that, a three dimensional (3D) finite element (FE) model of the whole process for 21-6-9 HSST was build based on FE platform of ABAQUS and validated by the experiment. Then, simulation and study of the process was carried out based on the FE model and the influence laws of clearance on wrinkling of 21-6-9 HSST in NC rotary draw bending were obtained. The results show that the wrinkling wave degree increases obviously with the increase of clearance between mandrel and tube Cm and clearance between bending die and tube Cb, while decreases with increase of clearance between pressure die and tube Cp; the wrinkling wave degree decreases sharply when clearance between wiper die and tube Cw is less than 0.2mm, and the wrinkling wave degree hardly has no variation when Cw is greater than 0.2mm.

  13. Evaluation of liver functional reserve by combining D-sorbitol clearance rate and CT measured liver volume

    Institute of Scientific and Technical Information of China (English)

    Yi-Ming Li; Fan Lv; Xin Xu; Hong Ji; Wen-Tao Gao; Tuan-Jie Lei; Gui-Bing Ren; Zhi-Lan Bai; Qiang Li

    2003-01-01

    AIM: Our research attempted to evaluate the overall functional reserve of cirrhotic liver by combination of hepatic functional blood flow, liver volume, and ChildPugh′s classification, and to discuss its value of clinical application.METHODS: Ninety two patients with portal hypertension due to hepatic cirrhosis were investigated. All had a historyof haematemesis and hematochezia, esophageal and gastric fundus varices, splenomegaly and hypersplenia.A 2-year follow-up was routinely performed and no one was lost. Twenty two healthy volunteers were used as control group. Blood and urine samples were collected 4times before and after intravenous D-sorbitol infusion.The hepatic clearance (CLH) of D-sorbitol was then calculated according to enzymatic spectrophotometric method while the total blood flow (QToTAL) and intrahepatic shunt (RINs) were detected by multicolor Doppler ultrasound, and the liver volume was measured by spiral CT. Data were estimated by t-test, variance calculation and chi-squared test. The relationships between all these parameters and different groups were investigated according to Child-Pugh classification and postoperative complications respectively.RESULTS: Steady blood concentration was achieved 120 mins after D-sorbitol intravenous infusion, which was (0.358±0.064) mmoⅠ@L-1 in cirrhotic group and (0.189±0.05)mmol@L-1 in control group (P<0.01). CLH=(812.7±112.4) ml@min-1,QTOTAL=(1280.6±131.4) ml@min-1, and RINS=(36.54±10.65)%in cirrhotic group and CLH=(1248.3±210.5) ml.min-1, QTOTAL=(1362.4-±126.9) ml@min-1, and RINS=(8.37±3.32) % in control group (P<0.01). The liver volume of cirrhotic group was 1057±249 cm3, 851±148 cm3 and 663±77 cm3 in Child A, B and C group respectively with significant difference (P<0.001).The average volume of cirrhotic liver in Child B, C group was significantly reduced in comparison with that in control group (P<0.001). The patient, whose liver volume decreased by 40 % with the CLH below 600 ml

  14. Effect of time and exercise on the clearance rate of (201)Tl in normal and ischemic myocardium.

    Science.gov (United States)

    Backus, Barbra E; Hezemans, Rachel E L; Verburg, Frederik A; Keijsersa, Ruth G M; Konijnenberg, Mark W; Verzijlbergen, J Fred

    2010-06-01

    Simultaneous dual isotope (SDI) acquisition of (201)Tl rest/(99m)Tc-sestamibi stress-myocardial perfusion single photon emission computed tomography is a desirable new procedure in nuclear cardiology. In this protocol (201)Tl is injected at rest but imaging is performed not earlier than after exercise. Therefore, one must be convinced that throughout exercise (201)Tl remains distributed in an identical pattern as at rest. Before SDI can be applied clinically, (201)Tl rest MPS before and after exercise test needs to be compared for equality. The aim of this study was to assess the effect of time and exercise on the clearance of preinjected (201)Tl in normal and ischemic myocardium. In 122 patients rest (201)Tl and delayed (n =20) or poststress (n= 102) (201)Tl imaging was performed. Quantitative analysis of mean counts-per-pixel was performed for each segment in a 17-segment model. Differences between rest and delayed or poststress (201)Tl MPS were calculated. Patients with a poststress (201)Tl image were divided into normal (N= 66) and ischemic (N= 36) groups. Visual analysis was performed by two independent observers scoring the 17 segments on a scale of 0-4. The overall difference between rest (201)Tl and poststress (201)Tl MPS was - 15.4%. Normal and ischemic patients showed 16.2 and 14.0% (P =0.17) washout, respectively. Visual assessment by two independent observers revealed no regional differences between rest (201)Tl and delayed or poststress (201)Tl MPS. (201)Tl poststress MPS shows significant washout of thallium. This washout is not segmental, but global over the myocardium. No significant differences are found between normal and ischemic myocardium. The poststress (201)Tl MPS is a reliable reflection of rest perfusion. SDI acquisition of (201)Tl rest/(99m)Tc-sestamibi stress-MPS is clinically applicable.

  15. Pressure attenuation during high-frequency airway clearance therapy across different size endotracheal tubes: An in vitro study.

    Science.gov (United States)

    Smallwood, Craig D; Bullock, Kevin J; Gouldstone, Andrew

    2016-08-01

    High-frequency airway clearance therapy is a positive pressure secretion clearance modality used in pediatric and adult applications. However, pressure attenuation across different size endotracheal tubes (ETT) has not been adequately described. This study quantifies attenuation in an in vitro model. The MetaNeb® System was used to deliver high-frequency pressure pulses to 3.0, 4.0, 6.0 and 8.0mm ID ETTs connected to a test lung during mechanical ventilation. The experimental setup included a 3D-printed trachea model and imbedded pressure sensors. The pressure attenuation (Patt%) was calculated: Patt%=[(Pproximal-Pdistal)/Pproximal]x100. The effect of pulse frequency on Pdistal and Pproximal was quantified. Patt% was inversely and linearly related to ETT ID and (y=-7.924x+74.36; R(2)=0.9917, P=.0042 for 4.0Hz pulse frequency and y=-7.382+9.445, R(2)=0.9964, P=.0018 for 3.0Hz pulse frequency). Patt% across the 3.0, 4.0, 6.0 and 8.0mm I.D. ETTs was 48.88±10.25%, 40.87±5.22%, 27.97±5.29%, and 9.90±1.9% respectively. Selecting the 4.0Hz frequency mode demonstrated higher Pproximal and Pdistal compared to the 3.0Hz frequency mode (P=.0049 and P=.0065). Observed Pdistal was <30cmH2O for all experiments. In an in vitro model, pressure attenuation was linearly related to the inner diameter of the endotracheal tube; with decreasing attenuation as the ETT size increased. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Investigation on the influence of leakage clearance on the flow field and performance of scroll hydraulic pump

    Science.gov (United States)

    Sun, Shuaihui; Huang, Yi; Guo, Pengcheng; Zuo, Juanli; Luo, Xingqi

    2016-11-01

    In the present paper, the computer fluid dynamics(CFD) with dynamic mesh model had been applied in scroll hydraulic pump to obtain its flow field at different leakage clearance. The fluid force on the orbiting scroll, the mass flow rate and the hydraulic efficiency at different leakage clearance were calculated based on the flow field data. The results indicated that when the leakage clearance increased from 0.5mm to 1.5mm, the average pressure, maximum of pressure fluctuation, leakage jet flow velocity, shaft power, cavitation degree decreased and the leakage flow rate increased. If the leakage clearance was 2.0mm, the high pressure discharge fluid flowed through the clearance and led to the increase of the average pressure and fluid force. When the leakage clearance is 1.0mm, the average pressure is far lower than that at the 0.5mm clearance, and the hydraulic efficiency is the highest.

  17. DEVELOPMENT OF ANTI-PERSONNEL MINE CLEARANCE ROBOT WITH HIGH SERVICEABILITY AND MANOEUVRABILITY FOR DETECTION AND DISACTIVATION OF EXPLOSIVE OBJECTS

    Directory of Open Access Journals (Sweden)

    D. Mironov

    2012-01-01

    Full Text Available A team of the BNTU researchers has developed an anti-personnel mine clearance robot that makes it possible to detect, disactivate or transport explosive objects to safe places excluding any danger to  human life. Performance characteristics of the anti-personnel mine clearance robot  surpass foreign analogues. 

  18. HBV/HCV co-infection is associated with a high level of HCV spontaneous clearance among drug users and blood donors in China.

    Science.gov (United States)

    Xiong, H; Rong, X; Wang, M; Xu, R; Huang, K; Liao, Q; Huang, J; Chen, J; Li, C; Tang, X; Shan, Z; Zhang, M; Nelson, K; Fu, Y

    2016-12-12

    Understanding the biology of spontaneous clearance of hepatitis C virus (HCV) infection could lead to improved strategies to prevent the sequelae associated with chronic HCV infection. Chronic infections with hepatitis virus are very common in China, but the factors associated with spontaneous clearance of HCV have not been adequately studied. We evaluated the spontaneous clearance of HCV among 1918 drug users and 1526 HCV-seropositive blood donors in Guangzhou, China. Among participants who were co-infected with hepatitis B virus (HBV), 41.38% of drug users and 39.47% of blood donors had cleared their HCV infection without antiviral therapy compared to 9.41% of drug users and 16.73% of blood donors who were mono-infected with a single virus (PHCV infection was significantly greater in the co-infected subjects whose serum HBV DNA was greater than 2000IU/mL than those with lower levels. A multiple logistic regression analysis found female gender, IL28B rs8099917 TT genotype, HBV co-infection and blood donors (vs drug users) associated with increased spontaneous clearance of HCV infection. Although acute HCV infections are common in China, the incidence of chronic HCV may be reduced among the high prevalence of chronic HBV and IL28B genotypes associated with spontaneous clearance of HCV in Chinese populations.

  19. Autism's 'Worryingly' High Suicide Rates Spur Conference

    Science.gov (United States)

    ... page: https://medlineplus.gov/news/fullstory_165946.html Autism's 'Worryingly' High Suicide Rates Spur Conference Signs of ... News) -- High rates of suicide among people with autism are drawing specialists to a conference this week ...

  20. Lithium clearance in chronic nephropathy

    DEFF Research Database (Denmark)

    Kamper, A L; Holstein-Rathlou, N H; Leyssac, P P

    1989-01-01

    1. Lithium clearance measurements were made in 72 patients with chronic nephropathy of different aetiology and moderate to severely reduced renal function. 2. Lithium clearance was strictly correlated with glomerular filtration rate, and there was no suggestion of distal tubular reabsorption...... clearance data were independent of whether renal disease was of primarily glomerular or tubular origin and, further, were not influenced by long-term conventional antihypertensive treatment. 6. It is concluded that, even with a reduced kidney function, the data are compatible with the suggestion...... that lithium clearance may be a measure of the delivery of sodium and water from the renal proximal tubule. With this assumption it was found that adjustment of the sodium excretion in chronic nephropathy initially takes place in the distal parts of the nephron (loop of Henle, distal tubule and collecting duct...

  1. Understanding High Rate Behavior Through Low Rate Analog

    Science.gov (United States)

    2014-04-28

    Dioh, N.N., et al., The High-Strain Rate Behavior of Polymers. Journal De Physique Iv, 1994. 4(C8): p. 119-124. 21. Dioh, N.N., P.S. Leevers, and J.G...constitutive response of polymeric materials as a function of temperature and strain rate. Journal De Physique Iv, 2003. 110: p. 27-32. 23. Brown, E.N...properties of polycarbonate under dynamic loading. Journal De Physique Iv, 2003. 110: p. 159-164. 56. Li, Z.H. and J. Lambros, Strain rate effects on the

  2. High phenobarbital clearance during continuous renal replacement therapy: a case report and pharmacokinetic analysis.

    Science.gov (United States)

    Rosenborg, Staffan; Saraste, Lars; Wide, Katarina

    2014-08-01

    Phenobarbital is an old antiepileptic drug used in severe epilepsy. Despite this, little is written about the need for dose adjustments in renal replacement therapy. Most sources recommend a moderately increased dose guided by therapeutic drug monitoring.A 14 year old boy with nonketotic hyperglycinemia, a rare inborn error of metabolism, characterized by high levels of glycine, epilepsy, spasticity, and cognitive impairment, was admitted to the emergency department with respiratory failure after a few days of fever and cough. The boy was unconscious at admittance and had acute renal and hepatic failure.Due to the acute respiratory infection, hypoxic hepatic and renal failure occurred and the patient had a status epilepticus.The patient was intubated and mechanically ventilated. Continuous renal replacement therapy was initiated. Despite increased phenobarbital doses, therapeutic levels were not reached until the dose was increased to 500 mg twice daily. Therapeutic drug monitoring was performed in plasma and dialysate. Calculations revealed that phenobarbital was almost freely dialyzed.Correct dosing of drugs in patients on renal replacement therapy may need a multidisciplinary approach and guidance by therapeutic drug monitoring.

  3. Effect of bottom clearance on performance of airlift bioreactor in high-density culture of Panax notoginseng cells.

    Science.gov (United States)

    Hu, W; Zhong, J

    2001-01-01

    A fed-batch cultivation of Panax notoginseng cells in a concentric-tube airlift reactor was performed to study the effects of bottom clearance on cell growth and the production of ginseng saponin and polysaccharide. At a bottom clearance of 4.0 cm, the highest cell density of 29.1+/-1.6 g/l by dry weight was obtained, and the accumulation of saponin and polysaccharide also reached a maximum, i.e., 2.39+/-0.43 and 2.73+/-0.40 g/l, respectively. Cell growth and metabolite production were limited at a small (2.5 cm) or large (5.0 cm) bottom clearance. By analyzing the time constants of mixing, mass transfer and oxygen consumption, bulk gas-liquid oxygen transfer was found to be responsible for the growth limitation at a small bottom clearance (2.5 cm). The decrease in cell density at a large bottom clearance (5.0 cm) was related to cell sedimentation at the reactor bottom. This work is beneficial for the scale-up and efficient operation of the airlift reactor in cell cultures.

  4. Lithium clearance in chronic nephropathy

    DEFF Research Database (Denmark)

    Kamper, A L; Holstein-Rathlou, N H; Leyssac, P P

    1989-01-01

    1. Lithium clearance measurements were made in 72 patients with chronic nephropathy of different aetiology and moderate to severely reduced renal function. 2. Lithium clearance was strictly correlated with glomerular filtration rate, and there was no suggestion of distal tubular reabsorption...... of lithium or influence of osmotic diuresis. 3. Fractional reabsorption of lithium was reduced in most patients with glomerular filtration rates below 25 ml/min. 4. Calculated fractional distal reabsorption of sodium was reduced in most patients with glomerular filtration rates below 50 ml/min. 5. Lithium...... that lithium clearance may be a measure of the delivery of sodium and water from the renal proximal tubule. With this assumption it was found that adjustment of the sodium excretion in chronic nephropathy initially takes place in the distal parts of the nephron (loop of Henle, distal tubule and collecting duct...

  5. Evaluating the Need for and Effect of Percutaneous Transluminal Angioplasty on Arteriovenous Fistulas by Using Total Recirculation Rate per Dialysis Session (“Clearance Gap”

    Directory of Open Access Journals (Sweden)

    Ugawa,Toyomu

    2012-12-01

    Full Text Available The functioning of an arteriovenous fistula (AVF used for vascular access during hemodialysis has been assessed mainly by dilution methods. Although these techniques indicate the immediate recirculation rate, the results obtained may not correlate with Kt/V. In contrast, the clearance gap (CL-Gap method provides the total recirculation rate per dialysis session and correlates well with Kt/V. We assessed the correlation between Kt/V and CL-Gap as well as the change in radial artery (RA blood flow speed in the fistula before percutaneous transluminal angioplasty (PTA in 45 patients undergoing continuous hemodialysis. The dialysis dose during the determination of CL-Gap was 1.2 to 1.4 Kt/V. Patients with a 10% elevation or more than a 10% relative increase in CL-Gap underwent PTA (n=45, and the values obtained for Kt/V and CL-Gap before PTA were compared with those obtained immediately afterward. The mean RA blood flow speed improved significantly (from 52.9 to 97.5cm/sec after PTA, as did Kt/V (1.07 to 1.30 and CL-Gap (14.1% to -0.2%. A significant correlation between these differences was apparent (r=-0.436 and p=0.003. These findings suggest that calculating CL-Gap may be useful for determining when PTA is required and for assessing the effectiveness of PTA, toward obtaining better dialysis.

  6. High burn rate solid composite propellants

    Science.gov (United States)

    Manship, Timothy D.

    High burn rate propellants help maintain high levels of thrust without requiring complex, high surface area grain geometries. Utilizing high burn rate propellants allows for simplified grain geometries that not only make production of the grains easier, but the simplified grains tend to have better mechanical strength, which is important in missiles undergoing high-g accelerations. Additionally, high burn rate propellants allow for a higher volumetric loading which reduces the overall missile's size and weight. The purpose of this study is to present methods of achieving a high burn rate propellant and to develop a composite propellant formulation that burns at 1.5 inches per second at 1000 psia. In this study, several means of achieving a high burn rate propellant were presented. In addition, several candidate approaches were evaluated using the Kepner-Tregoe method with hydroxyl terminated polybutadiene (HTPB)-based propellants using burn rate modifiers and dicyclopentadiene (DCPD)-based propellants being selected for further evaluation. Propellants with varying levels of nano-aluminum, nano-iron oxide, FeBTA, and overall solids loading were produced using the HTPB binder and evaluated in order to determine the effect the various ingredients have on the burn rate and to find a formulation that provides the burn rate desired. Experiments were conducted to compare the burn rates of propellants using the binders HTPB and DCPD. The DCPD formulation matched that of the baseline HTPB mix. Finally, GAP-plasticized DCPD gumstock dogbones were attempted to be made for mechanical evaluation. Results from the study show that nano-additives have a substantial effect on propellant burn rate with nano-iron oxide having the largest influence. Of the formulations tested, the highest burn rate was a 84% solids loading mix using nano-aluminum nano-iron oxide, and ammonium perchlorate in a 3:1(20 micron: 200 micron) ratio which achieved a burn rate of 1.2 inches per second at 1000

  7. Creatinine clearance test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003611.htm Creatinine clearance test To use the sharing features on this page, please enable JavaScript. The creatinine clearance test helps provide information about how well the ...

  8. High frame rate synthetic aperture duplex imaging

    DEFF Research Database (Denmark)

    Stuart, Matthias Bo; Tomov, Borislav Gueorguiev; Pihl, Michael Johannes

    2013-01-01

    aperture flow imaging as demonstrated in this paper. Synthetic aperture, directional beamforming, and cross-correlation are used to produce B-mode and vector velocity images at high frame rates. The frame rate equals the effective pulse repetition frequency of each imaging mode. Emissions for making the B...

  9. High-Rate Receiver Design Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose an initial architectural and preliminary hardware design study for a high-rate receiver capable of decoding modulation suites specified by CCSDS 413.0-G-1...

  10. Comparison of predictive accuracy of teicoplanin concentration using creatinine clearance and glomerular filtration rate estimated by serum creatinine or cystatin C.

    Science.gov (United States)

    Kozono, Aki; Hiraki, Yoichi; Adachi, Rui; Nagano, Masahisa; Inoue, Daisuke; Tsuji, Yasuhiro; Kamimura, Hidetoshi; Karube, Yoshiharu

    2016-05-01

    We compared the predictive accuracy of TEIC concentrations (TEIC_conc) calculated using either serum cystatin C (CysC) or serum creatinine (SCr) and the population mean method using the mean population parameter of TEIC_conc for Japan. We also compared the predicted TEIC_conc to measured TEIC_conc. Creatinine clearance (CLCr) predicted using the Cockcroft-Gault (C&G) equation with SCr was 45.23 mL/min (interquartile range [IQR]: 32.12-58.28), and the glomerular filtration rate (GFR) predicted using the Hoek equation with CysC was 45.23 mL/min (IQR: 35.40-53.79). The root mean-squared prediction error (IQR) based on CLCr predicted using the C&G equation with SCr was 6.88 (3.80-9.96) μg/mL, and that based on GFR predicted using the Hoek equation with CysC was 6.72 (3.77-9.68) μg/mL. Predicted TEIC_conc did not differ significantly between the two methods. The predictive accuracy of the TEIC_conc using the Hoek equation with CysC was similar to that of CLCr using the C&G equation with SCr. These findings suggest that the predictive accuracy of the TEIC_conc using CLCr based on the G&G equation and SCr might be sufficient for the initial dose adjustment of TEIC. Given that we were unable to confirm that CysC is the optimal method for predicting TEIC_conc, the expensive measurement of CysC might not be necessary.

  11. Numerical Simulation on the Effect of Tip Clearance Size on Unsteadiness in Tip Clearance Flow

    Institute of Scientific and Technical Information of China (English)

    Juan Du; Feng Lin; Hongwu Zhang; Jingyi Chen

    2008-01-01

    Unsteadiness of tip clearance flow with three different tip clearance sizes is numerically investigated in this paper. NASA Rotor 67 is chosen as the computational model. It is found that among all the simulated cases, the un-steadiness exists when the size of the tip clearance is equal to or larger than design tip clearance size. The relative total pressure coefficient contours indicate that region of influence by tip leakage flow augments with the increase of tip clearance size at a fixed mass flow rate. Root Mean Square contours of static pressure distribution in the rotor tip region are provided to illustrate that for design tip clearance (1.1% tip chord) the strongest fluctuating region is located on pressure side of blade near leading edge, while for the larger tip clearance (2.2% tip chord), it is in the region of the interaction between the shock wave and the tip leakage flow.

  12. 温度和盐度对企鹅珍珠贝清滤率、滤食率、吸收率的影响%Effects of temperature and salinity on clearance rate, filtration rate and absorption efficiency of Pteria penguin

    Institute of Scientific and Technical Information of China (English)

    栗志民; 刘志刚; 邓海东

    2011-01-01

    The effects of various seawater temperature and salinity on clearance rate, filtration rate and absorption efficiency of Pteria penguin were investigated by adopting the measures of experimental ecology,which would provide both insight into culturing capacity and physiology of cultivating pearl of Pteria penguin and reference for marine ecosystem restoration.The results were as follows: ( 1 ) the temperature had distinct effect on the clearance rate, filtration rate and absorption efficiency of Pteria penguin ( P < O.O1 ).The clearance rate, filtration rate and absorption efficiency of Pteria penguin increased with increasing water temperature under test temperature( 14 -32 ℃ ) ,which reached the peak at 29 ℃ and were 0.87 L/h,4.17 mg POM/h and 84.0l % ,respectively.Contrasting to 29 ℃ ,the clearance rate ,filtration rate and absorption efficiency of Pteria penguin began to decrease at 32 ℃, however, these three physiological indicators remain at higher level, suggesting that Pteria penguin is typical of the tropical and subtropical species and possesses good adaptability to high temperature.The more suitable sea water temperature for the feeding of Pteria penguin was 23 - 32 ℃, and the optimum sea water temperature was about 29 ℃.(2) the salinity had distinct effect on the clearance rate, filtration rate and absorption efficiency of Pteria penguin ( P < 0.01 ).The clearance rate, filtration rate and absorption efficiency of Pteria penguin increased with increasing water salinity under test salinity ( 19 - 37 ), which reached the maximum value with 0.36 L/h, 1.87 mg POM/h and 76.95% at 31 ,respectively.The clearance rate ,filtration rate and absorption efficiency of Pteria penguin began to decrease at 34 and 37, however, these three physiological indicators remain at higher level when salinity was at 34, suggesting that Pteria penguin is typical of narrow salinity shellfish and possesses good adaptability to high salinity.The more suitable sea

  13. Analyses toward factors influencing sealing clearance of a metal rubber seal and derivation of a calculation formula

    Institute of Scientific and Technical Information of China (English)

    Yan Hui; Zhao Yalei; Liu Jianguo; Jiang Hongyuan

    2016-01-01

    Sealing clearance is a key factor for a metal rubber seal’s sealability. The expansion coef-ficient and expansion deformation in the radial direction of metal rubber have been obtained through a thermal expansion experiment of metal rubber. The influence of the elastic modulus to the sealing clearance has been analyzed theoretically. By combining the temperature and elasticity factors of metal rubber with the elastic mechanics theory, the calculation formula of the sealing clearance has been derived, and the values of the sealing clearance and the leakage rate in certain working conditions have been calculated. Experimental results are consistent with calculation results in a high degree. The calculation formula of the sealing clearance can explain the influences of the temperature and elastic modulus factors of metal rubber on the sealing clearance. It can pro-vide guidance for the study of sealing mechanism of metal rubber seals.

  14. An Experimental Investigation of the Flow Physics Associated With End Wall Losses and Large Rotor Tip Clearances as Found in the Rear Stages of a High Pressure Compressor

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2015-01-01

    The focus of this work was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearance heights were studied with nominal tip clearance heights of 1.5%, 3.0%, and 4.0% based on a constant annulus height. Overall compressor performance was investigated at four corrected speedlines (100%, 90%, 80%, and 68%) for each of the three tip clearance configurations using total pressure and total temperature rakes distributed throughout the compressor. The results have confirmed results from previous authors showing a decrease of total pressure rise, isentropic efficiency, and stall margin which is approximately linear with increasing tip clearance height. The stall inception mechanisms have also been evaluated at the same corrected speeds for each of the tip clearance configurations. Detailed flow field measurements have been collected at two loading conditions, nominal loading (NL) and high loading (HL), on the 100% corrected speedline for the smallest and largest tip clearance heights (1.5% and 4.0%). Steady detailed radial traverses of total pressure at the exit of each stator row have been supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data have helped to quantify the size of the leakage flow at the exit of each rotor. Thermal anemometry has also been implemented to evaluate the time-resolved three-dimensional components of velocity throughout the compressor and calculate blockage due to the rotor tip leakage flow throughout the compressor. These

  15. Site clearance working group

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The Gulf of Mexico and Louisiana continue to be areas with a high level of facility removal, and the pace of removal is projected to increase. Regulations were promulgated for the Gulf of Mexico and Louisiana requiring that abandoned sites be cleared of debris that could interfere with fishing and shrimping activities. The site clearance regulations also required verification that the sites were clear. Additionally, government programs were established to compensate fishermen for losses associated with snagging their equipment on oil and gas related objects that remained on the water bottoms in areas other than active producing sites and sites that had been verified as clear of obstructions and snags. The oil and gas industry funds the compensation programs. This paper reviews the regulations and evolving operating practices in the Gulf of Mexico and Louisiana where site clearance and fisherman`s gear compensation regulations have been in place for a number of years. Although regulations and guidelines may be in place elsewhere in the world, this paper focuses on the Gulf of Mexico and Louisiana. Workshop participants are encouraged to bring up international issues during the course of the workshop. Additionally, this paper raises questions and focuses on issues that are of concern to the various Gulf of Mexico and Louisiana water surface and water bottom stakeholders. This paper does not have answers to the questions or issues. During the workshop participants will debate the questions and issues in an attempt to develop consensus opinions and/or make suggestions that can be provided to the appropriate organizations, both private and government, for possible future research or policy adjustments. Site clearance and facility removal are different activities. Facility removal deals with removal of the structures used to produce oil and gas including platforms, wells, casing, piles, pipelines, well protection structures, etc.

  16. Concomitant Administration of High-dose Methotrexate and Low-dose Aspirin Without Any Delay in Methotrexate Clearance in a Patient With Osteosarcoma: A Case Report and Review of the Literature.

    Science.gov (United States)

    Renzi, Samuele; Tsimerman, Ekaterina; Taylor, Tracey; Hopyan, Sevan; Koo, Alicia; Gupta, Abha

    2017-09-08

    Methotrexate (MTX) is a commonly used agent in the treatment of oncology patients whose clearance depends on renal health maintaining glomerular filtration and tubular secretion. Thus concomitant use of other drugs that utilize the same mechanism of clearance are generally avoided as this may contribute to increased MTX-associated toxicity. Herein, we describe the use of low-dose aspirin with high-dose MTX in a patient with osteosarcoma. Concomitant aspirin use did not affect the clearance of high-dose MTX and the patient did not experience any MTX-related toxicity including mucositis or renal impairment.

  17. Understanding High Saving Rate in China

    Institute of Scientific and Technical Information of China (English)

    Xinhua He; Yongfu Cao

    2007-01-01

    This paper presents a detailed analysis of the Chinese saving rate based on the flow of funds data. It finds that the most widely adopted view of precautionary saving, which is regarded as the top reason for maintaining a high saving rate in China, is misleading because this conclusion is drawn from the household survey data. In fact, the household saving rate has declined dramatically since the mid-1990s, as is observed from the flow of funds framework.The high national saving rate is attributed to the increasing shares of both government and corporation disposable incomes. Insufficient consumption demand is caused by the persistent decrease in percentage share of household to national disposable income. Governmentdirected income redistribution urgently needs to be improved to accelerate consumption,which in turn would make the Chinese economy less investment-led and help to reduce the current account surplus.

  18. A high-strain-rate superplastic ceramic.

    Science.gov (United States)

    Kim, B N; Hiraga, K; Morita, K; Sakka, Y

    2001-09-20

    High-strain-rate superplasticity describes the ability of a material to sustain large plastic deformation in tension at high strain rates of the order of 10-2 to 10-1 s-1 and is of great technological interest for the shape-forming of engineering materials. High-strain-rate superplasticity has been observed in aluminium-based and magnesium-based alloys. But for ceramic materials, superplastic deformation has been restricted to low strain rates of the order of 10-5 to 10-4 s-1 for most oxides and nitrides with the presence of intergranular cavities leading to premature failure. Here we show that a composite ceramic material consisting of tetragonal zirconium oxide, magnesium aluminate spinel and alpha-alumina phases exhibits superplasticity at strain rates up to 1 s-1. The composite also exhibits a large tensile elongation, exceeding 1,050 per cent for a strain rate of 0.4 s-1. The tensile flow behaviour and deformed microstructure of the material indicate that superplasticity is due to a combination of limited grain growth in the constitutive phases and the intervention of dislocation-induced plasticity in the zirconium oxide phase. We suggest that the present results hold promise for the application of shape-forming technologies to ceramic materials.

  19. Electrorheological Effects at High Shear Rate

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Much attention has been given to electrorheological (ER) fluids because of the ER effect, which has been described by a large number of researchers as a notable increase in the apparent viscosity of a fluid upon the application of an electric field. The description of ER effects is, however, not accurate at high shear rates. To clarify the discrepancy, we analyze and compute the apparent viscosity as a function of shear rate for ER fluid flow between rotating coaxial cylinders in the presence of an electric field. The theoretical predictions show that the increase of electric intensity contributes little to the apparent viscosity enhancement at high shear rates, while ER effects for ER fluids with a higher polarization rate still exist and ER devices possess controllability in this regime. Description of the ER effect by the apparent viscosity leads to an unrealistic conclusion that ER effects disappear at high shear rates, because the apparent viscosity of ER fluids approaches the value for Newtonian fluids. Therefore, it is concluded that the proper description of ER effects, i.e., one that holds uniformly for any strain rate when ER effects exist, is manifested by a remarkable increase in the extra stress rather than in the apparent viscosity of ER fluids.

  20. Thrombus Formation at High Shear Rates.

    Science.gov (United States)

    Casa, Lauren D C; Ku, David N

    2017-06-21

    The final common pathway in myocardial infarction and ischemic stroke is occlusion of blood flow from a thrombus forming under high shear rates in arteries. A high-shear thrombus forms rapidly and is distinct from the slow formation of coagulation that occurs in stagnant blood. Thrombosis at high shear rates depends primarily on the long protein von Willebrand factor (vWF) and platelets, with hemodynamics playing an important role in each stage of thrombus formation, including vWF binding, platelet adhesion, platelet activation, and rapid thrombus growth. The prediction of high-shear thrombosis is a major area of biofluid mechanics in which point-of-care testing and computational modeling are promising future directions for clinically relevant research. Further research in this area will enable identification of patients at high risk for arterial thrombosis, improve prevention and treatment based on shear-dependent biological mechanisms, and improve blood-contacting device design to reduce thrombosis risk.

  1. High Strain Rate Characterisation of Composite Materials

    DEFF Research Database (Denmark)

    Eriksen, Rasmus Normann Wilken

    The high strain rate characterisation of FRP materials present the experimenter with a new set of challenges in obtaining valid experimental data. These challenges were addressed in this work with basis in classic wave theory. The stress equilibrium process for linear elastic materials, as fibre...... a linear elastic specimen to reach a state of constant strain rate before fracture. This was in contrast to ductile materials, which are widely tested with for the High-speed servohydraulic test machine. The development of the analysis and the interpretation of the results, were based on the experience...

  2. Ultrasmall Glutathione-Protected Gold Nanoclusters as Next Generation Radiotherapy Sensitizers with High Tumor Uptake and High Renal Clearance

    CERN Document Server

    Zhang, Xiao-Dong; Chen, Jie; Song, Shasha; Yuan, Xun; Shen, Xiu; Wang, Hao; Sun, Yuanming; Gao, Kai; Zhang, Lianfeng; Fan, Saijun; Leong, David Tai; Guo, Meili; Xie, Jianping

    2015-01-01

    Radiotherapy is often the most straightforward first line cancer treatment for solid tumors. While it is highly effective against tumors, there is also collateral damage to healthy proximal tissues especially with high doses. The use of radiosensitizers is an effective way to boost the killing efficacy of radiotherapy against the tumor while drastically limiting the received dose and reducing the possible damage to normal tissues. Here, we report the design and application of a good radiosensitizer by using ultrasmall gold nanoclusters with a naturally occurring peptide (e.g., glutathione or GSH) as the protecting shell. The GSH coated gold nanoclusters can escape the RES absorption, leading to a good tumor uptake (8.1% ID/g at 24 h post injection). As a result, the as-designed Au nanoclusters led to a strong enhancement for radiotherapy, as well as a negligible damage to normal tissues. After the treatment, the ultrasmall gold nanoclusters can be efficiently cleared by the kidney, thereby avoiding potential ...

  3. Development of a modular virus clearance package for anion exchange chromatography operated in weak partitioning mode.

    Science.gov (United States)

    Iskra, Timothy; Sacramo, Ashley; Gallo, Chris; Godavarti, Ranga; Chen, Shuang; Lute, Scott; Brorson, Kurt

    2015-01-01

    Anion exchange chromatography (AEX) operated under weak partitioning mode has been proven to be a powerful polishing step as well as a robust viral clearance step in Pfizer's monoclonal antibody (mAb) platform purification process. A multivariate design of experiment (DoE) study was conducted to understand the impact of operating parameters and feedstream impurity levels on viral clearance by weak partitioning mode AEX. Bacteriophage was used initially as a surrogate for neutral and acidic isoelectric point mammalian viruses (e.g., retrovirus and parvovirus). Five different mAbs were used in the evaluation of process parameters such as load challenge (both product and impurities), load pH, load conductivity, and contact time (bed height and flow-rate). The operating ranges obtained from phage clearance studies and Pfizer's historical data were used to define an appropriate operating range for a subsequent clearance study with model retrovirus and parvovirus. Both phage and virus clearance evaluations included feedstreams containing different levels of impurities such as high molecular mass species (HMMS), host cell proteins (HCPs), and host cell DNA. For all the conditions tested, over 5 log10 of clearance for both retrovirus and parvovirus was achieved. The results demonstrated that weak partitioning mode AEX chromatography is a robust step for viral clearance and has the potential to be included as part of the modular viral clearance approach.

  4. High Resolution Measurement of the Glycolytic Rate

    Science.gov (United States)

    Bittner, Carla X.; Loaiza, Anitsi; Ruminot, Iván; Larenas, Valeria; Sotelo-Hitschfeld, Tamara; Gutiérrez, Robin; Córdova, Alex; Valdebenito, Rocío; Frommer, Wolf B.; Barros, L. Felipe

    2010-01-01

    The glycolytic rate is sensitive to physiological activity, hormones, stress, aging, and malignant transformation. Standard techniques to measure the glycolytic rate are based on radioactive isotopes, are not able to resolve single cells and have poor temporal resolution, limitations that hamper the study of energy metabolism in the brain and other organs. A new method is described in this article, which makes use of a recently developed FRET glucose nanosensor to measure the rate of glycolysis in single cells with high temporal resolution. Used in cultured astrocytes, the method showed for the first time that glycolysis can be activated within seconds by a combination of glutamate and K+, supporting a role for astrocytes in neurometabolic and neurovascular coupling in the brain. It was also possible to make a direct comparison of metabolism in neurons and astrocytes lying in close proximity, paving the way to a high-resolution characterization of brain energy metabolism. Single-cell glycolytic rates were also measured in fibroblasts, adipocytes, myoblasts, and tumor cells, showing higher rates for undifferentiated cells and significant metabolic heterogeneity within cell types. This method should facilitate the investigation of tissue metabolism at the single-cell level and is readily adaptable for high-throughput analysis. PMID:20890447

  5. High resolution measurement of the glycolytic rate

    Directory of Open Access Journals (Sweden)

    Carla X Bittner

    2010-09-01

    Full Text Available The glycolytic rate is sensitive to physiological activity, hormones, stress, aging and malignant transformation. Standard techniques to measure the glycolytic rate are based on radioactive isotopes, are not able to resolve single cells and have poor temporal resolution, limitations that hamper the study of energy metabolism in the brain and other organs. A new method is described in this article, which makes use of a recently-developed FRET glucose nanosensor to measure the rate of glycolysis in single cells with high temporal resolution. Used in cultured astrocytes, the method showed for the first time that glycolysis can be activated within seconds by a combination of glutamate and K+, supporting a role for astrocytes in neurometabolic and neurovascular coupling in the brain. It was also possible to make a direct comparison of metabolism in neurons and astrocytes lying in close proximity, paving the way to a high-resolution characterization of brain energy metabolism. Single-cell glycolytic rates were also measured in fibroblasts, adipocytes, myoblasts and tumor cells, showing higher rates for undifferentiated cells and significant metabolic heterogeneity within cell types. This method should facilitate the investigation of tissue metabolism at the single-cell level and is readily adaptable for high-throughput analysis.

  6. High rate, high reliability Li/SO2 cells

    Science.gov (United States)

    Chireau, R.

    1982-03-01

    The use of the lithium/sulfur dioxide system for aerospace applications is discussed. The high rate density in the system is compared to some primary systems: mercury zinc, silver zinc, and magnesium oxide. Estimates are provided of the storage life and shelf life of typical lithium sulfur batteries. The design of lithium cells is presented and criteria are given for improving the output of cells in order to achieve high rate and high reliability.

  7. High Rate Performing Li-ion Battery

    Science.gov (United States)

    2015-02-09

    permeable to lithium ions and efficient in transferring the electrons into/from the LVP surface to the corresponding current collector. a) b) c) d) e...PO4)3/C for High Rate Lithium-ion Battery Applications”, Lee Hwang Sheng, Nail Suleimanov, Vishwanathan Ramar, Mangayarkarasi Murugan, Kuppan

  8. [Hopes of high dose-rate radiotherapy].

    Science.gov (United States)

    Fouillade, Charles; Favaudon, Vincent; Vozenin, Marie-Catherine; Romeo, Paul-Henri; Bourhis, Jean; Verrelle, Pierre; Devauchelle, Patrick; Patriarca, Annalisa; Heinrich, Sophie; Mazal, Alejandro; Dutreix, Marie

    2017-04-01

    In this review, we present the synthesis of the newly acquired knowledge concerning high dose-rate irradiations and the hopes that these new radiotherapy modalities give rise to. The results were presented at a recent symposium on the subject. Copyright © 2017. Published by Elsevier Masson SAS.

  9. Understanding High School Graduation Rates in Arizona

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  10. Understanding High School Graduation Rates in Delaware

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  11. Understanding High School Graduation Rates in Idaho

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  12. Understanding High School Graduation Rates in Illinois

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  13. Understanding High School Graduation Rates in Massachusetts

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  14. Understanding High School Graduation Rates in Pennsylvania

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  15. Understanding High School Graduation Rates in Minnesota

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  16. Understanding High School Graduation Rates in Kentucky

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  17. Understanding High School Graduation Rates in Maryland

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  18. Understanding High School Graduation Rates in Wisconsin

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  19. Understanding High School Graduation Rates in Wyoming

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  20. Understanding High School Graduation Rates in Alaska

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  1. Understanding High School Graduation Rates in Oklahoma

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  2. Understanding High School Graduation Rates in Tennessee

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  3. Understanding High School Graduation Rates in Georgia

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  4. Understanding High School Graduation Rates in Iowa

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  5. Understanding High School Graduation Rates in Nevada

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  6. Understanding High School Graduation Rates in Texas

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  7. Understanding High School Graduation Rates in Florida

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  8. Understanding High School Graduation Rates in Nebraska

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  9. Understanding High School Graduation Rates in Oregon

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  10. Understanding High School Graduation Rates in Kansas

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  11. Understanding High School Graduation Rates in Virginia

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  12. Understanding High School Graduation Rates in Connecticut

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  13. Understanding High School Graduation Rates in Hawaii

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  14. Understanding High School Graduation Rates in Vermont

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  15. Understanding High School Graduation Rates in Mississippi

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  16. Understanding High School Graduation Rates in California

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  17. Understanding High School Graduation Rates in Ohio

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  18. Understanding High School Graduation Rates in Montana

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  19. Understanding High School Graduation Rates in Maine

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  20. Understanding High School Graduation Rates in Washington

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  1. Understanding High School Graduation Rates in Louisiana

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  2. Understanding High School Graduation Rates in Colorado

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  3. Understanding High School Graduation Rates in Michigan

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  4. Understanding High School Graduation Rates in Indiana

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  5. Understanding High School Graduation Rates in Utah

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  6. Understanding High School Graduation Rates in Alabama

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  7. Understanding High School Graduation Rates in Arkansas

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  8. Understanding High School Graduation Rates in Missouri

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  9. A miniature high repetition rate shock tube.

    Science.gov (United States)

    Tranter, R S; Lynch, P T

    2013-09-01

    A miniature high repetition rate shock tube with excellent reproducibility has been constructed to facilitate high temperature, high pressure, gas phase experiments at facilities such as synchrotron light sources where space is limited and many experiments need to be averaged to obtain adequate signal levels. The shock tube is designed to generate reaction conditions of T > 600 K, P shock waves with predictable characteristics are created, repeatably. Two synchrotron-based experiments using this apparatus are also briefly described here, demonstrating the potential of the shock tube for research at synchrotron light sources.

  10. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H;

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were m...

  11. Security Clearance Tracking System

    Data.gov (United States)

    National Archives and Records Administration — SCTS supports the adjudication process of private background investigations and clearances for potential employees, contractors, interns and student workers.

  12. High strain rate behaviour of polypropylene microfoams

    Science.gov (United States)

    Gómez-del Río, T.; Garrido, M. A.; Rodríguez, J.; Arencón, D.; Martínez, A. B.

    2012-08-01

    Microcellular materials such as polypropylene foams are often used in protective applications and passive safety for packaging (electronic components, aeronautical structures, food, etc.) or personal safety (helmets, knee-pads, etc.). In such applications the foams which are used are often designed to absorb the maximum energy and are generally subjected to severe loadings involving high strain rates. The manufacture process to obtain polymeric microcellular foams is based on the polymer saturation with a supercritical gas, at high temperature and pressure. This method presents several advantages over the conventional injection moulding techniques which make it industrially feasible. However, the effect of processing conditions such as blowing agent, concentration and microfoaming time and/or temperature on the microstructure of the resulting microcellular polymer (density, cell size and geometry) is not yet set up. The compressive mechanical behaviour of several microcellular polypropylene foams has been investigated over a wide range of strain rates (0.001 to 3000 s-1) in order to show the effects of the processing parameters and strain rate on the mechanical properties. High strain rate tests were performed using a Split Hopkinson Pressure Bar apparatus (SHPB). Polypropylene and polyethylene-ethylene block copolymer foams of various densities were considered.

  13. High strain rate behaviour of polypropylene microfoams

    Directory of Open Access Journals (Sweden)

    Martínez A.B.

    2012-08-01

    Full Text Available Microcellular materials such as polypropylene foams are often used in protective applications and passive safety for packaging (electronic components, aeronautical structures, food, etc. or personal safety (helmets, knee-pads, etc.. In such applications the foams which are used are often designed to absorb the maximum energy and are generally subjected to severe loadings involving high strain rates. The manufacture process to obtain polymeric microcellular foams is based on the polymer saturation with a supercritical gas, at high temperature and pressure. This method presents several advantages over the conventional injection moulding techniques which make it industrially feasible. However, the effect of processing conditions such as blowing agent, concentration and microfoaming time and/or temperature on the microstructure of the resulting microcellular polymer (density, cell size and geometry is not yet set up. The compressive mechanical behaviour of several microcellular polypropylene foams has been investigated over a wide range of strain rates (0.001 to 3000 s−1 in order to show the effects of the processing parameters and strain rate on the mechanical properties. High strain rate tests were performed using a Split Hopkinson Pressure Bar apparatus (SHPB. Polypropylene and polyethylene-ethylene block copolymer foams of various densities were considered.

  14. Plasma Creatinine Clearance in the Dog

    Science.gov (United States)

    Frazier, Loy W.

    1977-01-01

    Lists materials and methods for an experiment that demonstrates the concept of glomerular filtration rate (GFR) using anesthesized dogs. In the dog, GFR is equivalent to the renal plasma clearance of exogenous creatinine. (CS)

  15. Lactate clearance in cardiorespiratory emergency

    Directory of Open Access Journals (Sweden)

    Serena Greco

    2007-08-01

    Full Text Available Early goal directed therapy has been found to improve prognosis in septic patients, if the therapeutic goal is achieved within the first six hours. The aim of our study is to demonstrate that in patients with acute cardiorespiratory failure, rapid (within 2 hours lactate clearance can help define patients’ prognosis. 67 consecutive patients, admitted to our 16-bed Emergency Medicine ward for acute cardiorespiratory failure (age 75,9 ± 9,8 (APACHE II score 19,0 ± 4,1, were included in the study. Blood lactate concentration was read at admission and after 2, 6 and 24 hours. We evaluated mortality at seven days and the use of orotracheal intubation (patients with negative outcome vs. discharge or transfer to a non-emergency ward with subsequent discharge (patients with negative outcome. Lactate concentration at admission was 4,6 ± 2,5 mmol/l; lactate clearance (% at 2 hours was 40,4 ± 32,1 in patients with a positive outcome and –8,3 ± 5,0 in patients with a negative outcome (p < 0,05. Lactate clearance at 2 hours < 25% is correlated to a negative outcome with an 84,2% sensitivity and a 79,2% specificity. The positive predictive value was 61,5% and the negative predictive value was 92,2%. Systematic lactate clearance monitoring can be used in cases of acute cardiorespiratory insufficiency to identify patients with a high risk of negative outcome. In our study, low clearance at two hours was associated with an increase in mortality and/or the need for orotracheal intubation. Conversely, a clearance at two hours of > 25% in most cases confirms the therapeutic strategy undertaken. Serial evaluation of blood lactate concentration may therefore be useful in guiding treatment strategies.

  16. High strain rate characterization of polymers

    Science.gov (United States)

    Siviour, Clive R.

    2017-01-01

    This paper reviews the literature on the response of polymers to high strain rate deformation. The main focus is on the experimental techniques used to characterize this response. The paper includes a small number of examples as well as references to experimental data over a wide range of rates, which illustrate the key features of rate dependence in these materials; however this is by no means an exhaustive list. The aim of the paper is to give the reader unfamiliar with the subject an overview of the techniques available with sufficient references from which further information can be obtained. In addition to the `well established' techniques of the Hopkinson bar, Taylor Impact and Transverse impact, a discussion of the use of time-temperature superposition in interpreting and experimentally replicating high rate response is given, as is a description of new techniques in which mechanical parameters are derived by directly measuring wave propagation in specimens; these are particularly appropriate for polymers with low wave speeds. The vast topic of constitutive modelling is deliberately excluded from this review.

  17. A prototype of a high rating MRPC

    Institute of Scientific and Technical Information of China (English)

    WANG Yi; WANG Jing-Bo; YAN Qiang; LI Yuan-Jing; CHENG Jian-Ping; YUE Qian; LI Jin

    2009-01-01

    Six-gap resistive plate chamber (MRPC) prototypes with semiconductive glass electrodes (bulk resistivity~1010.cm) were studied for suitability in time-of-flight (TOF) applications at high rates. These studies were performed using a continuous electron beam of 800 MeV at IHEP and an X-ray machine. Time resolutions of about 100 ps and efficiencies larger than 90% were obtained for flux densities up to 28 kHz/cm2.

  18. Reserve, flowing electrolyte, high rate lithium battery

    Science.gov (United States)

    Puskar, M.; Harris, P.

    Flowing electrolyte Li/SOCl2 tests in single cell and multicell bipolar fixtures have been conducted, and measurements are presented for electrolyte flow rates, inlet and outlet temperatures, fixture temperatures at several points, and the pressure drop across the fixture. Reserve lithium batteries with flowing thionyl-chloride electrolytes are found to be capable of very high energy densities with usable voltages and capacities at current densities as high as 500 mA/sq cm. At this current density, a battery stack 10 inches in diameter is shown to produce over 60 kW of power while maintaining a safe operating temperature.

  19. Influence of Cold Exposure on Ventilation, Respiratory Heat Loss, and Pulmonary Deposition/Clearance

    Science.gov (United States)

    1990-06-25

    13 Particle Deposition in the Lung. .......... 15 Particle Clearance from the Airways . ........ 17 REFERENCES.........................21 III... airways and lung. Should hypoventilation result in increased deposition or decreased clearance , it could not be considered advantageous in this regard, but...cold and cold-induced hypoventilation upon the clearance rate of particles from the upper airways is addressed in Chapter V. Nasal clearance rate was

  20. High strain rate deformation of layered nanocomposites

    Science.gov (United States)

    Lee, Jae-Hwang; Veysset, David; Singer, Jonathan P.; Retsch, Markus; Saini, Gagan; Pezeril, Thomas; Nelson, Keith A.; Thomas, Edwin L.

    2012-11-01

    Insight into the mechanical behaviour of nanomaterials under the extreme condition of very high deformation rates and to very large strains is needed to provide improved understanding for the development of new protective materials. Applications include protection against bullets for body armour, micrometeorites for satellites, and high-speed particle impact for jet engine turbine blades. Here we use a microscopic ballistic test to report the responses of periodic glassy-rubbery layered block-copolymer nanostructures to impact from hypervelocity micron-sized silica spheres. Entire deformation fields are experimentally visualized at an exceptionally high resolution (below 10 nm) and we discover how the microstructure dissipates the impact energy via layer kinking, layer compression, extreme chain conformational flattening, domain fragmentation and segmental mixing to form a liquid phase. Orientation-dependent experiments show that the dissipation can be enhanced by 30% by proper orientation of the layers.

  1. Effects of changes in lung volume on oscillatory flow rate during high-frequency chest wall oscillation

    OpenAIRE

    Scott J Butcher; Pasiorowski, Michal P; Jones, Richard L

    2007-01-01

    BACKGROUND: The effectiveness of high-frequency chest wall oscillation (HFCWO) in mucolysis and mucous clearance is thought to be dependant on oscillatory flow rate (Fosc). Therefore, increasing Fosc during HFCWO may have a clinical benefit.OBJECTIVES: To examine effects of continuous positive airway pressure (CPAP) on Fosc at two oscillation frequencies in healthy subjects and patients with airway obstruction.METHODS: Five healthy subjects and six patients with airway obstruction underwent 1...

  2. High frame-rate digital radiographic videography

    Energy Technology Data Exchange (ETDEWEB)

    King, N.S.P.; Cverna, F.H.; Albright, K.L.; Jaramillo, S.A.; Yates, G.J.; McDonald, T.E. [Los Alamos National Lab., NM (United States); Flynn, M.J.; Tashman, S. [Henry Ford Health System, Detroit, MI (United States)

    1994-09-01

    High speed x-ray imaging can be an important tool for observing internal processes in a wide range of applications. In this paper we describe preliminary implementation of a system having the eventual goal of observing the internal dynamics of bone and joint reactions during loading. Two Los Alamos National Laboratory (LANL) gated and image intensified camera systems were used to record images from an x-ray image convertor tube to demonstrate the potential of high frame-rate digital radiographic videography in the analysis of bone and joint dynamics of the human body. Preliminary experiments were done at LANL to test the systems. Initial high frame-rate imaging (from 500 to 1000 frames/s) of a swinging pendulum mounted to the face of an X-ray image convertor tube demonstrated high contrast response and baseline sensitivity. The systems were then evaluated at the Motion Analysis Laboratory of Henry Ford Health Systems Bone and Joint Center. Imaging of a 9 inch acrylic disk with embedded lead markers rotating at approximately 1000 RPM, demonstrated the system response to a high velocity/high contrast target. By gating the P-20 phosphor image from the X-ray image convertor with a second image intensifier (II) and using a 100-microsecond wide optical gate through the second II, enough prompt light decay from the x-ray image convertor phosphor had taken place to achieve reduction of most of the motion blurring. Measurement of the marker velocity was made by using video frames acquired at 500 frames/s. The data obtained from both experiments successfully demonstrated the feasibility of the technique. Several key areas for improvement are discussed along with salient test results and experiment details.

  3. Novel High Rate Lithium Intercalation Cathode Materials

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Application of amorphous V2O5/carbon/neodymium oxide (Nd2O3) composite is one of ways to surmount the lower electrical conductivity of V2O5. A new type of V2O5/carbon/Nd2O3 composite was prepared by mixing vanadium oxide hydrosol, acetone, carbon and Nd2O3 powder. High rate discharge/charge property of the composite electrode was tested electrochemically. This composite with Nd2O3 added shows the improvement of not only the discharge capacity but also cycle durability discharge capacity. The rate capability of the composite cathode also increases with the addition of Nd2O3.and cycle life are probably caused by the increase in porosity of open pores and short diffusion length of the active material on the lithium-ion insertion.

  4. Turbomachinery Clearance Control

    Science.gov (United States)

    Chupp, Raymond E.; Hendricks, Robert C.; Lattime, Scott B.; Steinetz, Bruce M.; Aksit, Mahmut F.

    2007-01-01

    Controlling interface clearances is the most cost effective method of enhancing turbomachinery performance. Seals control turbomachinery leakages, coolant flows and contribute to overall system rotordynamic stability. In many instances, sealing interfaces and coatings are sacrificial, like lubricants, giving up their integrity for the benefit of the component. They are subjected to abrasion, erosion, oxidation, incursive rubs, foreign object damage (FOD) and deposits as well as extremes in thermal, mechanical, aerodynamic and impact loadings. Tribological pairing of materials control how well and how long these interfaces will be effective in controlling flow. A variety of seal types and materials are required to satisfy turbomachinery sealing demands. These seals must be properly designed to maintain the interface clearances. In some cases, this will mean machining adjacent surfaces, yet in many other applications, coatings are employed for optimum performance. Many seals are coating composites fabricated on superstructures or substrates that are coated with sacrificial materials which can be refurbished either in situ or by removal, stripping, recoating and replacing until substrate life is exceeded. For blade and knife tip sealing an important class of materials known as abradables permit blade or knife rubbing without significant damage or wear to the rotating element while maintaining an effective sealing interface. Most such tip interfaces are passive, yet some, as for the high-pressure turbine (HPT) case or shroud, are actively controlled. This work presents an overview of turbomachinery sealing. Areas covered include: characteristics of gas and steam turbine sealing applications and environments, benefits of sealing, types of standard static and dynamics seals, advanced seal designs, as well as life and limitations issues.

  5. Experimental recombination rates for highly charged ions

    Energy Technology Data Exchange (ETDEWEB)

    Reinhold Schuch [Dept. of Atomic Physics, Stockholm Univ., Frescativ., Stockholm (Sweden)

    2000-01-01

    Recent studies of recombination between free electrons and highly charged ions using electron coolers of heavy-ion storage rings have produced accurate rate coefficients of interest for plasma modeling and diagnostics. Some surprises were discovered which can lead to revisions of recombination models. With bare ions one finds at low energy a strong and puzzling deviation from radiative recombination theory. Dielectronic recombination with C3+, N4+ show that jj coupling gives essential contributions to the cross section also for light ions. (author)

  6. Apolipoprotein E mediates enhanced plasma high-density lipoprotein cholesterol clearance by low-dose streptococcal serum opacity factor via hepatic low-density lipoprotein receptors in vivo.

    Science.gov (United States)

    Rosales, Corina; Tang, Daming; Gillard, Baiba K; Courtney, Harry S; Pownall, Henry J

    2011-08-01

    Recombinant streptococcal serum opacity factor (rSOF) mediates the in vitro disassembly of human plasma high-density lipoprotein (HDL) into lipid-free apolipoprotein (apo) A-I, a neo-HDL that is cholesterol poor, and a cholesteryl ester-rich microemulsion (CERM) containing apoE. Given the occurrence of apoE on the CERM, we tested the hypothesis that rSOF injection into mice would reduce total plasma cholesterol clearance via apoE-dependent hepatic low-density lipoprotein receptors (LDLR). rSOF (4 μg) injection into wild-type C57BL/6J mice formed neo-HDL, CERM, and lipid-free apoA-I, as observed in vitro, and reduced plasma total cholesterol (-43%, t(1/2)=44±18 minutes) whereas control saline injections had a negligible effect. Similar experiments with apoE(-/-) and LDLR(-/-) mice reduced plasma total cholesterol ≈0% and 20%, respectively. rSOF was potent; injection of 0.18 μg of rSOF produced 50% of maximum reduction of plasma cholesterol 3 hours postinjection, corresponding to a ≈0.5-mg human dose. Most cholesterol was cleared hepatically (>99%), with rSOF treatment increasing clearance by 65%. rSOF injection into mice formed a CERM that was cleared via hepatic LDLR that recognize apoE. This reaction could provide an alternative mechanism for reverse cholesterol transport.

  7. Recrystallization of High Carbon Steel during High Strain Rate

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The recrystallization of high carbon steel during high temperature and high speed rolling has been studied by analyzing the stress-strain curves and the austenite grain size.Isothermal multi-pass hot compression at high strain rate was carried out by Gleeble-2000. The austenite grain size was measured by IBAS image analysis system. The results show that static recrystallization occurred at interpass time under pre-finish rolling, and at the finish rolling stage, due to the brief interpass time, static recrystallization can not be found.

  8. Use of clearance rate in Choromytilus chorus (Bivalvia: Mytilidae) as a non-destructive biomarker of aquatic pollution El uso de la tasa de aclaramiento en Choromytilus chorus (Bivalvia: Mytilidae) como biomarcador no destructivo de la polución acuática

    OpenAIRE

    BEATRIZ TORO; Jorge M Navarro; HERNÁN PALMA-FLEMING

    2003-01-01

    Reduction in clearance rate was observed in the mussel Choromytilus chorus in relation to the degree of environmental pollution. Three sampling sites included the polluted San Vicente Bay, middling polluted Corral Bay, and weakly polluted Yaldad Bay in southern Chile. Pollution levels were estimated by quantitative analysis of polynuclear aromatic hydrocarbons (PAHs) in mussel tissue from the three sites. Mussels from San Vicente showed lowest clearance rates and highest PAHs levels in both s...

  9. High counting rate resistive-plate chamber

    Science.gov (United States)

    Peskov, V.; Anderson, D. F.; Kwan, S.

    1993-05-01

    Parallel-plate avalanche chambers (PPAC) are widely used in physics experiments because they are fast (less than 1 ns) and have very simple construction: just two parallel metallic plates or mesh electrodes. Depending on the applied voltage they may work either in spark mode or avalanche mode. The advantage of the spark mode of operation is a large signal amplitude from the chamber, the disadvantage is that there is a large dead time (msec) for the entire chamber after an event. The main advantage of the avalanche mode is high rate capability 10(exp 5) counts/mm(sup 2). A resistive-plate chamber (RPC) is similar to the PPAC in construction except that one or both of the electrodes are made from high resistivity (greater than 10(exp 10) Omega(cm) materials. In practice RPC's are usually used in the spark mode. Resistive electrodes are charged by sparks, locally reducing the actual electric field in the gap. The size of the charged surface is about 10 mm(sup 2), leaving the rest of the detector unaffected. Therefore, the rate capability of such detectors in the spark mode is considerably higher than conventional spark counters. Among the different glasses tested the best results were obtained with electron type conductive glasses, which obey Ohm's law. Most of the work with such glasses was done with high pressure parallel-plate chambers (10 atm) for time-of-flight measurements. Resistive glasses have been expensive and produced only in small quantities. Now resistive glasses are commercially available, although they are still expensive in small scale production. From the positive experience of different groups working with the resistive glasses, it was decided to review the old idea to use this glass for the RPC. This work has investigated the possibility of using the RPC at 1 atm and in the avalanche mode. This has several advantages: simplicity of construction, high rate capability, low voltage operation, and the ability to work with non-flammable gases.

  10. High-energy, high-rate materials processing

    Science.gov (United States)

    Marcus, H. L.; Bourell, D. L.; Eliezer, Z.; Persad, C.; Weldon, W.

    1987-12-01

    The increasingly available range of pulsed-power, high energy kinetic storage devices, such as low-inductance pulse-forming networks, compulsators, and homopolar generators, is presently considered as a basis for industrial high energy/high rate (HEHR) processing to accomplish shock hardening, drilling, rapid surface alloying and melting, welding and cutting, transformation hardening, and cladding and surface melting in metallic materials. Time-temperature-transformation concepts furnish the basis for a fundamental understanding of the potential advantages of this direct pulsed power processing. Attention is given to the HEHR processing of a refractory molybdenum alloy, a nickel-base metallic glass, tungsten, titanium aluminides, and metal-matrix composites.

  11. High-Frame-Rate Oil Film Interferometry

    CERN Document Server

    White, Jonathan C; Chen, John

    2010-01-01

    The fluid dynamics video to which this abstract relates contains visualization of the response of a laminar boundary layer to a sudden puff from a small hole. The boundary layer develops on a flat plate in a wind tunnel; the hole is located at a streamwise Reynolds number of 100,000. The visualization of the boundary layer response is accomplished using interferometry of a transparent, thin film of oil placed on the surface immediately downstream of the hole and with its leading edge perpendicular to the direction of flow. Through lubrication theory, it is understood that the rate of change of the spacing of the interference fringes is proportional to the skin friction at any instant. For reference, a small disk-shaped protrusion of the type often used to trip the boundary layer in wind model tunnel testing is also shown. Three cases with different puff strengths are included. Using a high-speed commercial camera, frame rates in excess of 1000/sec have been recorded; the video shown here was taken at 24 frame...

  12. High spin rate magnetic controller for nanosatellites

    Science.gov (United States)

    Slavinskis, A.; Kvell, U.; Kulu, E.; Sünter, I.; Kuuste, H.; Lätt, S.; Voormansik, K.; Noorma, M.

    2014-02-01

    This paper presents a study of a high rate closed-loop spin controller that uses only electromagnetic coils as actuators. The controller is able to perform spin rate control and simultaneously align the spin axis with the Earth's inertial reference frame. It is implemented, optimised and simulated for a 1-unit CubeSat ESTCube-1 to fulfil its mission requirements: spin the satellite up to 360 deg s-1 around the z-axis and align its spin axis with the Earth's polar axis with a pointing error of less than 3°. The attitude of the satellite is determined using a magnetic field vector, a Sun vector and angular velocity. It is estimated using an Unscented Kalman Filter and controlled using three electromagnetic coils. The algorithm is tested in a simulation environment that includes models of space environment and environmental disturbances, sensor and actuator emulation, attitude estimation, and a model to simulate the time delay caused by on-board calculations. In addition to the normal operation mode, analyses of reduced satellite functionality are performed: significant errors of attitude estimation due to non-operational Sun sensors; and limited actuator functionality due to two non-operational coils. A hardware-in-the-loop test is also performed to verify on-board software.

  13. High readmission rate after heart valve surgery

    DEFF Research Database (Denmark)

    Sibilitz, K L; Berg, S K; Thygesen, Lau Caspar;

    2015-01-01

    of anxiety and depression were present in 13.6% and 13.8%, respectively (Hospital Anxiety and Depression Scale score ≥ 8). Twelve months following discharge, 483 persons (56%) were readmitted. Readmission was associated with lower self-reported health (SF-36 PCS: 46.5 vs. 43.9, and MCS 52.2 vs. 50.7). Higher...... after surgery (3.2 (1.2-8.9)) predicted mortality. CONCLUSIONS: 6-12 months after heart valve surgery the readmission rate is high and the self-reported health status is low. Readmission is associated with low self-reported health. Therefore, targeted follow-up strategies post-surgery are needed....

  14. Consideration of wear rates at high velocity

    Science.gov (United States)

    Hale, Chad S.

    The development of the research presented here is one in which high velocity relative sliding motion between two bodies in contact has been considered. Overall, the wear environment is truly three-dimensional. The attempt to characterize three-dimensional wear was not economically feasible because it must be analyzed at the micro-mechanical level to get results. Thus, an engineering approximation was carried out. This approximation was based on a metallographic study identifying the need to include viscoplasticity constitutive material models, coefficient of friction, relationships between the normal load and velocity, and the need to understand wave propagation. A sled test run at the Holloman High Speed Test Track (HHSTT) was considered for the determination of high velocity wear rates. In order to adequately characterize high velocity wear, it was necessary to formulate a numerical model that contained all of the physical events present. The experimental results of a VascoMax 300 maraging steel slipper sliding on an AISI 1080 steel rail during a January 2008 sled test mission were analyzed. During this rocket sled test, the slipper traveled 5,816 meters in 8.14 seconds and reached a maximum velocity of 1,530 m/s. This type of environment was never considered previously in terms of wear evaluation. Each of the features of the metallography were obtained through micro-mechanical experimental techniques. The byproduct of this analysis is that it is now possible to formulate a model that contains viscoplasticity, asperity collisions, temperature and frictional features. Based on the observations of the metallographic analysis, these necessary features have been included in the numerical model, which makes use of a time-dynamic program which follows the movement of a slipper during its experimental test run. The resulting velocity and pressure functions of time have been implemented in the explicit finite element code, ABAQUS. Two-dimensional, plane strain models

  15. High tumour stage and margin clearance are still important prognostic factors for post-mastectomy locoregional recurrence in Malaysia.

    Science.gov (United States)

    Choong, Lau Peng; Taib, Nur Aishah Mohd; Rampal, Sanjay; Saad, Marniza; Bustam, Anita Zarina; Yip, Cheng-Har

    2010-01-01

    Locoregional recurrence after mastectomy for breast cancer may predict distant recurrence and mortality. This study examined the pattern and rates of post-mastectomy locoregional recurrence (PMLRR), survival outcome and prognostic factors for isolated PMLRR (ILR) in a breast cancer cohort in University of Malaya Medical Center (UMMC). We studied 522 patients who underwent mastectomy between 1998 and 2002 and followed them up until 2008. We defined PMLRR as recurrence to the axilla, supraclavicular nodes and or chest wall. ILR was defined as PMLRR occurring as an isolated event. Prognostic factors for locoregional recurrence were determined using the Cox proportional hazards regression model. The overall PMLRR rate was 16.4%. ILR developed in 42 of 522 patients (8.0%). Within this subgroup, 25 (59.5%) remained disease free after treatment while 17 (40.5%) suffered disease progression. Univariate analyses identified race, age, size, stage, margin involvement, lymph node involvement, grade, lymphovascular invasion and ER status as probable prognostic factors for ILR. Cox regression resulted in only stage III disease and margin involvement as independent prognostic factors. The hazard of ILR was 2.5 times higher when the margins were involved compared to when they were clear (aHRR 2.5; 95% CI 1.3 to 5.0). Similarly, compared with stage I those with Stage II (aHRR 2.1; 95%CI 0.6 to 6.8) and stage III (aHRR 4.6; 95%CI 1.4 to 15.9) had worse prognosis for ILR. Margin involvement and stage III disease were identified to be independent prognostic factors for ILR. Close follow-up of high risk patients and prompt treatment of locoregional recurrence were recommended.

  16. Upgrade Strategy for ALICE at High Rate

    CERN Document Server

    Musa, L

    2012-01-01

    The longterm goal of the ALICE experiment is to provide a precise characterization of the Quark-Gluon Plasma (QGP) state. Such a determination of its properties including initial temperature, degrees of freedom, speed of sound, and in general, transport coefficients would be a major achievement. This would go a long way towards a better understanding of QCD as a genuine multi-particle theory. To achieve this goal, high statistics measurements are required, which will give access also to the very rare physics channels needed to understand the dynamics of this condensed phase of QCD. The general upgrade strategy for the ALICE central barrel is conceived to deal with this challenge with expected Pb-Pb interaction rates of up to 50 kHz, that would provide an accumulated sample of the order of 10 nb^-1 in the period 2019-2023. In this document we sketch the modifications/replacements needed in all ALICE central barrel detectors and online systems (Trigger, DAQ and HLT) for high luminosity running. As the ALICE for...

  17. 温度、盐度、pH和饵料密度对皱肋文蛤清滤率的影响%Effects of temperature, salinity, pH, and microalgae density on clearance rates of Meretrix lyrata

    Institute of Scientific and Technical Information of China (English)

    栗志民; 刘志刚; 徐法军; 李明昊

    2011-01-01

    The farming of the clam Meretrix lyrata has been successfully developed since 1987 and brought high economic and social benefits to the coastal communities. As a highly valued fishery resource especially in Vietnam, recently M. Lyrata has become another new aqua-culture species with a potential for large-scale farming in the South China Sea and a good market prospects. In this study, by adopting the ecology experimental methods, the effects of seawater temperatures, salinities, pH, and microalgae densities on the clearance rates of M. Lyrata were investigated, which are expected to provide insight on culturing capacity, feeding behavior and energy of M. Lyrata and references for healthy culturing and extension of M. Lyrata. The results showed that the clearance rates of M. Lyrata (P<0. 01) at three sizes were significantly affected by varied temperature (13~33℃), salinity (13~33), pH (7~9), and diet density (2. 5×104~10×104 cell/ml). The maximum clearance rates of the large, medium, and small sized M. Lyrata were 1. 06, 1. 78 and 2. 42 L/g ? H at 28℃ respectively, 0. 35, 0. 65 and 1. 05 L/g ? H at salinity 23, 1. 26, 1. 67 and 2. 02 L/g ? H at pH 8,1. 29, 2. 07 and 2. 29 L/g ? H at microalgae density of 10 × 104 cell/ml. These results indicate that the optimum feeding environ mental conditions were: temperature 28℃, salinity 23, pH 8 and microalgae density 10 × 104 cell/ml. These results indicate that the sensitivity of the large, medium and small sized M. Lyrata to temperature, salinity, pH or microalgae density appeared in the following order: large size<[medium size

  18. Airway clearance therapy in cystic fibrosis patients.

    Science.gov (United States)

    Pisi, Giovanna; Chetta, Alfredo

    2009-08-01

    Cystic fibrosis (CF) is the most common life-shortening inherited disease affecting Caucasian people. In CF, the major feature of lung disease is the retention of mucus due to impaired clearance of abnormally viscous airway secretions. Airway clearance techniques (ACTs) may significantly improve mucociliary clearance and gas exchange, thereby being of clinical benefit in reducing pulmonary complications in CF patients. ACTs include conventional chest physiotherapy, active cycle of breathing techniques, autogenic drainage, positive expiratory pressure and high-frequency chest compression. In order to suit the needs of patients, families and care-givers, ACTs need to be individually and continuously adapted.

  19. Evaluación de la tasa de aclaración de la almeja dulceacuícola Anodontites tortolis en un medio con coliformes Escherichia coli Clearance rate of faecal coliforms by netropical freshwater clam

    Directory of Open Access Journals (Sweden)

    Juan René Mallama Leyton

    2011-01-01

    Full Text Available En condiciones de laboratorio se evaluón acute; la eficiencia de la almeja de agua dulce (Anodontites tortolis) para disminuir la carga de coliformes fecales (Escherichia coli) determinada mediante filtración en membrana por 8 horas. El experimento se diseñó con dos tratamientos (densidades de seis (T1) y ocho almejas (T2) más un control) con tres replicaciones. Se encontraron diferencias significativas (PUnder laboratory conditions the efficiency of the freshwater clam Anodontites tortolis to diminish the quantity of faecal coliforms, determined by the membrane filtration method during eight hours was evaluated. The experiment was design with two treatments (two densities of six (T1) and eight clams (T2) and a control) and three replications. Statistical significant differences (P<0.05) according to the Kruskal-Wallis test for the clearance rates were found. The highest levels of remotion of E. coli belonged to the treatment in which there was the highest number of individuals. The clearance rate of the clams varied between 0.47 and 3.80 l.h-1.ind-1 which is reported in the literature. Removal levels showing A. tortolis suggest that this clam can be used as a biological resource for the treatment of the tertiary waters contaminated with faecal coliform bacteria.

  20. Prevalence, Incidence, and Clearance of Anogenital Warts in Kenyan Men Reporting High-Risk Sexual Behavior, Including Men Who Have Sex With Men

    Science.gov (United States)

    Neme, Santiago; Wahome, Elizabeth; Mwashigadi, Grace; Thiong'o, Alexander N.; Stekler, Joanne D.; Wald, Anna; Sanders, Eduard J.; Graham, Susan M.

    2015-01-01

    Background. Human papillomavirus (HPV) causes a spectrum of disease, ranging from warts to cancer. Prevalence, incidence, and factors associated with anogenital warts in East African men are unknown. Methods. Kenyan men reporting high-risk sexual behavior were inspected for anogenital warts at enrollment and follow-up visits. Logistic regression was performed to identify associations with anogenital warts at baseline. Cox regression was performed to analyze predictors of incident anogenital warts, and Kaplan–Meier curves were used to estimate clearance. Results. Baseline anogenital wart prevalence in 1137 men was 2.9% (95% confidence interval [CI], 2.0%–4.0%) overall, 2.0% in human immunodeficiency virus (HIV)-uninfected men, and 9.4% in HIV-1-infected men (adjusted odds ratio, 5.43; 95% CI, 2.03–11.29). Over a median of 1.4 years, anogenital wart incidence among 1104 men was 5.3 (95% CI, 4.3–6.5) per 100 person-years. Having HIV-1 infection at baseline (adjusted hazard ratio [aHR], 1.66; 95% CI, 1.01–2.72) or a genital syndrome during follow-up (aHR, 4.78; 95% CI, 3.03–7.56) was associated with increased wart incidence. Wart clearance was lower in HIV-1-infected men (log-rank Pwart prevalence and incidence were increased in HIV-1-infected men, and anogenital warts co-occurred with other genital syndromes. Quadrivalent HPV vaccination should be recommended for young men in settings with high HIV-1 prevalence. PMID:26110169

  1. Spontaneous Clearance of Hepatitis C after Liver and Renal Transplantation

    Directory of Open Access Journals (Sweden)

    CH Dale

    2009-01-01

    Full Text Available Spontaneous clearance of hepatitis C virus (HCV is rare in immunocompromised patients, such as those who have undergone organ transplantation. It has been recognized that patients receiving liver transplantation for HCV-related disease have decreased graft and patient survival compared with those transplanted for other etiologies. There is a growing trend toward treating HCV recurrence aggressively after liver transplantation. For other organ transplant recipients with concurrent HCV, treatment is not often an option, given the high rates of graft rejection and loss secondary to interferon and its immunomodulatory effects. Although spontaneous clearance of HCV has been reported in recipients of solitary liver and renal transplants, a common factor arising in these cases has been previous exposure to interferon. To date, no reports of spontaneous clearance of HCV RNA have been reported in a multiorgan transplant recipient. A case of spontaneous clearance of HCV RNA in an immunocompromised patient, within five months of simultaneous liver and kidney retransplantation is described. Importantly, this patient had no previous exposure to interferon.

  2. Short-term comparative study of high frequency chest wall oscillation and European airway clearance techniques in patients with cystic fibrosis

    Science.gov (United States)

    Roughton, Michael; Hodson, Margaret E; Pryor, Jennifer A

    2009-01-01

    Background High frequency chest wall oscillation (HFCWO) is standard treatment for airway clearance in the USA and has recently been introduced in the UK and Europe. There is little published research comparing HFCWO with airway clearance techniques (ACTs) frequently used in the UK and Europe. The aim of this study was to compare the short-term effects of HFCWO with usual ACTs in patients with cystic fibrosis hospitalised with an infective pulmonary exacerbation. Methods A 4-day randomised crossover design was used. Patients received either HFCWO on days 1 and 3 and usual ACTs on days 2 and 4 or vice versa. Wet weight of sputum, spirometry and oxygen saturation were measured. Perceived efficacy, comfort, incidence of urinary leakage and preference were assessed. Data were analysed by mixed model analysis. Results 29 patients (72% male) of mean (SD) age 29.4 (8.4) years and mean (SD) forced expiratory volume in 1 s (FEV1) percentage predicted (FEV1%) 38 (16.7) completed the study. Significantly more sputum was expectorated during a single treatment session and over a 24 h period (mean difference 4.4 g and 6.9 g, respectively) with usual ACTs than with HFCWO (p<0.001). No statistically significant change in FEV1% or oxygen saturation was observed after either HFCWO or usual ACTs compared with baseline. 17 patients (55%) expressed a preference for their usual ACT. Conclusions During both a finite treatment period and over 24 h, less sputum was cleared using HFCWO than usual ACT. HFCWO does not appear to cause any adverse physiological effects and may influence adherence. PMID:19703826

  3. The clearance of oral high-risk human papillomavirus infection is impaired by long-term persistence of cervical human papillomavirus infection.

    Science.gov (United States)

    Louvanto, K; Rautava, J; Syrjänen, K; Grénman, S; Syrjänen, S

    2014-11-01

    Persistence of high-risk (HR-) human papillomavirus (HPV) infection of the uterine cervix increases the risk of cervical cancer. Oral HPV infections are among potential covariates of long-term genotype-specific persistent cervical HR-HPV infections. It is not known whether this persistence reflects inability of the host to reject HPV infections in general. A case-control setting was designed to estimate the covariates of long-term persistent cervical HR-HPV infections using multivariate generalized estimating equation (GEE) models. HPV was detected with PCR using GP05+/GP06+-primers and genotyped for 24 HPVs with a Multimetrix-kit. The cases (n=43) included women who had genotype-specific persistent cervical HR-HPV infection for at least 24 months (24M+) and controls were women who tested repeatedly HPV-negative in their cervical samples (n=52). These women represent a sub-cohort of the Finnish Family HPV Study. The cases differed significantly from the HPV-negative controls in several aspects: they were younger, had a longer mean time to incident oral HPV infection (40.7 versus 23.6 months), longer duration of oral HPV persistence (38.4 versus 14.1 months), and longer time to clearance of their oral HPV infection (50.0 versus 28.2 months). In multivariate GEE analysis, the second pregnancy during the follow up was the only independent predictor with significant protective effect against 24M+ persistent cervical HR-HPV infections, OR of 0.15 (95% CI 0.07-0.34). To conclude, long-term persistent cervical HR-HPV infections are associated with a prolonged clearance of oral HR-HPV infections while new pregnancy protects against persistent cervical HR-HPV infections. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.

  4. Beta-cell dysfunction and low insulin clearance in insulin-resistant human immunodeficiency virus (HIV)-infected patients with lipodystrophy

    DEFF Research Database (Denmark)

    Haugaard, Steen B; Andersen, Ove; Vølund, Aage;

    2005-01-01

    with insulin sensitivity) and insulin clearance rate were reduced in lipodystrophic patients (-55%, P clearance rate correlated strongly with insulin sensitivity (r = 0.82, P ... and diabetes mellitus (63%vs. 20%, P clearance....

  5. High voltage high repetition rate pulse using Marx topology

    Science.gov (United States)

    Hakki, A.; Kashapov, N.

    2015-06-01

    The paper describes Marx topology using MOSFET transistors. Marx circuit with 10 stages has been done, to obtain pulses about 5.5KV amplitude, and the width of the pulses was about 30μsec with a high repetition rate (PPS > 100), Vdc = 535VDC is the input voltage for supplying the Marx circuit. Two Ferrite ring core transformers were used to control the MOSFET transistors of the Marx circuit (the first transformer to control the charging MOSFET transistors, the second transformer to control the discharging MOSFET transistors).

  6. Hepatic Clearance Prediction of Nine Human Immunodeficiency Virus Protease Inhibitors in Rat

    OpenAIRE

    2016-01-01

    This study aimed to determine the rate-limiting step in the overall hepatic clearance of the marketed human immunodeficiency virus (HIV) protease inhibitors (PI) in rats by predicting the experimentally determined hepatic in vivo clearance of these drugs based on in vitro clearance values for uptake and/or metabolism. In vitro uptake and metabolic clearance values were determined in suspended rat hepatocytes and rat liver microsomes, respectively. In vivo hepatic clearance was determined afte...

  7. HIgh Rate X-ray Fluorescence Detector

    Energy Technology Data Exchange (ETDEWEB)

    Grudberg, Peter Matthew [XIA LLC

    2013-04-30

    The purpose of this project was to develop a compact, modular multi-channel x-ray detector with integrated electronics. This detector, based upon emerging silicon drift detector (SDD) technology, will be capable of high data rate operation superior to the current state of the art offered by high purity germanium (HPGe) detectors, without the need for liquid nitrogen. In addition, by integrating the processing electronics inside the detector housing, the detector performance will be much less affected by the typically noisy electrical environment of a synchrotron hutch, and will also be much more compact than current systems, which can include a detector involving a large LN2 dewar and multiple racks of electronics. The combined detector/processor system is designed to match or exceed the performance and features of currently available detector systems, at a lower cost and with more ease of use due to the small size of the detector. In addition, the detector system is designed to be modular, so a small system might just have one detector module, while a larger system can have many you can start with one detector module, and add more as needs grow and budget allows. The modular nature also serves to simplify repair. In large part, we were successful in achieving our goals. We did develop a very high performance, large area multi-channel SDD detector, packaged with all associated electronics, which is easy to use and requires minimal external support (a simple power supply module and a closed-loop water cooling system). However, we did fall short of some of our stated goals. We had intended to base the detector on modular, large-area detectors from Ketek GmbH in Munich, Germany; however, these were not available in a suitable time frame for this project, so we worked instead with pnDetector GmbH (also located in Munich). They were able to provide a front-end detector module with six 100 m^2 SDD detectors (two monolithic arrays of three elements each) along with

  8. Cheetah: A high frame rate, high resolution SWIR image camera

    Science.gov (United States)

    Neys, Joel; Bentell, Jonas; O'Grady, Matt; Vermeiren, Jan; Colin, Thierry; Hooylaerts, Peter; Grietens, Bob

    2008-10-01

    A high resolution, high frame rate InGaAs based image sensor and associated camera has been developed. The sensor and the camera are capable of recording and delivering more than 1700 full 640x512pixel frames per second. The FPA utilizes a low lag CTIA current integrator in each pixel, enabling integration times shorter than one microsecond. On-chip logics allows for four different sub windows to be read out simultaneously at even higher rates. The spectral sensitivity of the FPA is situated in the SWIR range [0.9-1.7 μm] and can be further extended into the Visible and NIR range. The Cheetah camera has max 16 GB of on-board memory to store the acquired images and transfer the data over a Gigabit Ethernet connection to the PC. The camera is also equipped with a full CameralinkTM interface to directly stream the data to a frame grabber or dedicated image processing unit. The Cheetah camera is completely under software control.

  9. The evidence for secretion clearance techniques.

    Science.gov (United States)

    Hess, D R

    2001-11-01

    Many acute and chronic respiratory diseases are associated with increased respiratory secretions in the airways. Narrative reviews and a few systematic reviews of secretion clearance techniques have been published. These reviews raise concerns regarding the lack of evidence to support the various secretion clearance techniques. I conducted a comprehensive MEDLINE search of the following subjects: chest physical therapy, chest physiotherapy, postural drainage, forced expiratory technique, autogenic drainage, high-frequency chest wall compression, flutter device and secretions, positive expiratory pressure and secretions, intrapulmonary percussion, mechanical in-exsufflation and secretions. This was followed by a comprehensive search of cross-references to identify additional studies. The results of this review are reported herein. There are a number of methodological limitations of the literature reporting studies of the use of secretion clearance techniques. Most of the studies were small, most used crossover designs, and few used sham therapy. Many studies were limited to short-term outcomes such as sputum clearance with a single treatment session. Despite the clinical observation that retained secretions are detrimental to respiratory function and despite anecdotal associations between secretion clearance and improvements in respiratory function, there is a dearth of high-level evidence to support any secretion clearance technique.

  10. [{sup 131}I]Iodoazomycin arabinoside for low-dose-rate isotope radiotherapy: radiolabeling, stability, long-term whole-body clearance and radiation dosimetry estimates in mice

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Piyush [Department of Oncologic Imaging, Cross Cancer Institute, University of Alberta, Edmonton, Alberta, T6G 2N8 (Canada); McQuarrie, Steven A. [Department of Oncologic Imaging, Cross Cancer Institute, University of Alberta, Edmonton, Alberta, T6G 2N8 (Canada); Faculty of Pharmacy and Pharmaceutical Sciences, University of Alberta, Edmonton, Alberta, T6G 2N8 (Canada); Zhou, Aihya [Faculty of Pharmacy and Pharmaceutical Sciences, University of Alberta, Edmonton, Alberta, T6G 2N8 (Canada); McEwan, Alexander J.B. [Department of Oncologic Imaging, Cross Cancer Institute, University of Alberta, Edmonton, Alberta, T6G 2N8 (Canada); Wiebe, Leonard I. [Department of Oncologic Imaging, Cross Cancer Institute, University of Alberta, Edmonton, Alberta, T6G 2N8 (Canada) and Faculty of Pharmacy and Pharmaceutical Sciences, University of Alberta, Edmonton, Alberta, T6G 2N8 (Canada)]. E-mail: leonard.wiebe@ualberta.ca

    2005-08-01

    Background: The preliminary characterization of [{sup 131}I]iodoazomycin arabinoside ([{sup 131}I]IAZA) as a potential radiotherapeutic radiopharmaceutical is described. Methods: High-specific-activity [{sup 131}I]IAZA was prepared in therapeutic doses (up to 3 GBq per batch) by isotope exchange in pivalic acid melt and was purified on Sep-Pak cartridges. Stability in 15% ethanol in saline at 4 deg C was determined by high-performance liquid chromatography. IAZA cytotoxicity (IC{sub 50}, {approx}0.1 mM) against both murine (EMT-6) and human (143B, 143B-LTK) tumor cells determined by MTT test was in the range previously reported for EMT-6 cells using a clonogenic assay. Tissue radioactivity levels were measured in a murine tumor model for the 24- to 168-h postinjection period. Radiation dose estimates obtained from the tissue activity levels for this period were calculated from pharmacokinetic (WinNonlin) and dosimetry (MIRD and RAdiation Dose Assessment Resource) parameters. Results: The radioiodination efficiency was >90%, but with systematic losses during Sep-Pak purification, the recovered yields of [{sup 131}I]IAZA were {approx}75%. The product (specific activity, 4.6-6.4 GBq/{mu}mol) was stable for at least 2 weeks, with only {approx}6% degradation over this storage period. Extended biodistribution studies in Balb/c mice bearing implanted EMT-6 tumors showed that the highest tumor/blood radioactivity ratio (T/B; 4.8) occurred 24 h after dosing; the T/B ratio was {approx}1.5 at the end of the 7-day study. The 24- to 168-h tissue radioactivity data fit a one-compartment model except for liver data, which best fit a two-compartment model. Dosimetry estimates showed a tumor self-dose of 7.4 mGy/MBq, which is several-fold higher than for the liver or the kidney. Conclusions: [{sup 131}I]IAZA can be efficiently radiolabeled at high specific activity, purified by a simple Sep-Pak technique and stored with little radiolysis or chemical decomposition at these specific

  11. Mucus transport mechanisms in relation to the effect of high frequency chest compression (HFCC) on mucus clearance.

    Science.gov (United States)

    Hansen, L G; Warwick, W J; Hansen, K L

    1994-02-01

    High frequency chest compression (HFCC) appears promising as a form of chest physiotherapy. Studies published by several clinical centers support its efficacy, and further clinical data are expected to become available.

  12. Adult male northern elephant seals maintain high rates of glucose production during extended breeding fasts.

    Science.gov (United States)

    Crocker, Daniel E; Wenzel, Brian K; Champagne, Cory D; Houser, Dorian S

    2017-04-18

    Many species undergo natural fasts as part of their life histories. Extended fasting is associated with increased β-oxidation of fatty acids and reduced oxidation of glucose to minimize commitment of body protein to gluconeogenesis. However, the metabolic strategies used to sustain extended fasts simultaneous with high rates of energy expenditure are not well understood. Studies in fasting adult female and weanling northern elephant seals (NES) have revealed high rates of endogenous glucose production (EGP) under constraints of high nutrient demand for lactation or development but relatively low rates of metabolism. These studies revealed low rates of glucose oxidation and high rates of glucose recycling through the Cori cycle. We measured rates of glucose flux in fasting adult male NES to assess how significantly longer fasting durations, higher metabolic rates, and greater rates of muscular activity affect glucose kinetics. We measured glucose turnover in 18 adult males using the clearance of [6-H(3)] glucose during breeding and molting. Adult male NES maintain high rates of EGP across extended fasts. EGP greatly exceeded estimated needs for glucose-dependent tissues, varied directly with plasma insulin and lactate concentrations, and was inversely related to plasma ketoacid concentrations. Together, these findings suggest that high rates of glucose production and recycling during breeding maintain high blood glucose levels to support glucose-dependent tissues while minimizing production of ketoacids and commitment of protein stores to glucose production.

  13. The Myth of a High Savings Rate

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    In an attempt to entice consumers to save less and spend more, China has focused on perfecting its social security system, reforming taxation and dividend-sharing proportion between the government and state-owned enterprises. Liu Yuhui, Director of the China Economy Appraisal and Rating Center at the Institute of Finance and Banking, the Chinese Academy of Social Sciences, offered his insights in an Economic Observer article. Edited excerpts follow

  14. The Combustion of HMX. [burning rate at high pressures

    Science.gov (United States)

    Boggs, T. L.; Price, C. F.; Atwood, A. I.; Zurn, D. E.; Eisel, J. L.

    1980-01-01

    The burn rate of HMX was measured at high pressures (p more than 1000 psi). The self deflagration rate of HMX was determined from 1 atmosphere to 50,000 psi. The burning rate shows no significant slope breaks.

  15. Evaluating the Impact of Uncertainties in Clearance and Exposure When Prioritizing Chemicals Screened in High-Throughput Assays

    Science.gov (United States)

    The toxicity-testing paradigm has evolved to include high-throughput (HT) methods for addressing the increasing need to screen hundreds to thousands of chemicals rapidly. Approaches that involve in vitro screening assays, in silico predictions of exposure concentrations, and phar...

  16. LIQUID ARGON CALORIMETER PERFORMANCE AT HIGH RATES

    CERN Document Server

    Kukhtin, V; The ATLAS collaboration

    2011-01-01

    The performance of the ATLAS liquid argon endcap and forward calorimeters has been projected at the planned high luminosity LHC option HL-LHC by exposing small calorimeter modules of the electromagnetic, hadronic, and forward calorimeters to high intensity proton beams at IHEP/Protvino accelerator. The results of HV current and of pulse shape analysis, and also the dependence of signal amplitude on beam intensity are presented.

  17. High Reproduction Rate versus Sexual Fidelity

    OpenAIRE

    Sousa, A. O.; de Oliveira, S. Moss

    2000-01-01

    We introduce fidelity into the bit-string Penna model for biological ageing and study the advantage of this fidelity when it produces a higher survival probability of the offspring due to paternal care. We attribute a lower reproduction rate to the faithful males but a higher death probability to the offspring of non-faithful males that abandon the pups to mate other females. The fidelity is considered as a genetic trait which is transmitted to the male offspring (with or without error). We s...

  18. Smoking Rates Still High in Some Racial Groups, CDC Reports

    Science.gov (United States)

    ... page: https://medlineplus.gov/news/fullstory_160256.html Smoking Rates Still High in Some Racial Groups, CDC ... lot of progress in getting Americans to stop smoking, some groups still have high smoking rates, a ...

  19. Clearance of high-risk papillomavirus after LEEP for high-grade squamous intraepithelial lesions and it's relationship with CD4+ T cell%CD4+T细胞与宫颈高度鳞状上皮内病变锥切后高危型乳头瘤病毒消退的关系

    Institute of Scientific and Technical Information of China (English)

    黎华文; 张丽凡; 邓鹏飞; 冯家成

    2012-01-01

    Objective It is to investigate the clearance of hrHPV after LEEP for high-grade squamous intraepithelial lesions and it's relationship to CD4 + T cell. Methods A retrospective study was conducted on 120 patients who underwent LEEP for high grade squamous intraepithelial lesions. Results Among those who were hrHPV infected before LEEP, the clearance rate of hrHPV was 81. 82% , 90. 91% , 94. 55% and 96. 36% after 6 months' , 12 months' , 18 months' and 24 months' treatment respectively. The positive expression rate of CD4 + T cell in hrHPV infected cases was 37. 84% . The clearance of hrHPV in the cases whose expression of CD4 + T cell was positive was higher than that of the other cases. Conclusion hrHPV mainly disappear in two years after LEEP, and T cells immune may has a relationship with this clearance of hrHPV.%目的 探讨CD4+T细胞与宫颈高度鳞状上皮内病变锥切后高危型乳头瘤病毒(hrHPV)消退的关系.方法 对因宫颈高度鳞状上皮内病变行宫颈电环切除术120例患者的随访资料进行回顾性分析.结果 术前hrHPV的阳性率为91.67%,术后6,12,18,24个月hrHPV清除率分别为81.82%,90.91%,94.55%,96.36%,术前hrHPV阳性者CD4+T细胞的表达率为37.84%,术后6个月CD4+T细胞阳性者hrHPV消除率显著高于CD4+T细胞阴性者.结论 宫颈电环切除术后2a hrHPV基本消退,T细胞免疫可能与术后hrHPV的消退有关系.

  20. High frame rate imaging based photometry

    DEFF Research Database (Denmark)

    Harpsøe, Kennet Bomann West; Jørgensen, U. G.; Andersen, M. I.;

    2012-01-01

    in conventional CCDs, and new methods for handling these must be developed. We aim to investigate how the normal photometric reduction steps from conventional CCDs should be adjusted to be applicable to EMCCD data. One complication is that a bias frame cannot be obtained conventionally, as the output from...... an EMCCD is not normally distributed. Also, the readout process generates spurious charges in any CCD, but in EMCCD data, these charges are visible as opposed to the conventional CCD. Furthermore we aim to eliminate the photon waste associated with lucky imaging by combining this method with shift......-and-add. A simple probabilistic model for the dark output of an EMCCD is developed. Fitting this model with the expectation-maximization algorithm allows us to estimate the bias, readout noise, amplification, and spurious charge rate per pixel and thus correct for these phenomena. To investigate the stability...

  1. High Count Rate Electron Probe Microanalysis

    Science.gov (United States)

    Geller, Joseph D.; Herrington, Charles

    2002-01-01

    Reducing the measurement uncertainty of quantitative analyses made using electron probe microanalyzers (EPMA) requires a careful study of the individual uncertainties from each definable step of the measurement. Those steps include measuring the incident electron beam current and voltage, knowing the angle between the electron beam and the sample (takeoff angle), collecting the emitted x rays from the sample, comparing the emitted x-ray flux to known standards (to determine the k-ratio) and transformation of the k-ratio to concentration using algorithms which includes, as a minimum, the atomic number, absorption, and fluorescence corrections. This paper discusses the collection and counting of the emitted x rays, which are diffracted into the gas flow or sealed proportional x-ray detectors. The representation of the uncertainty in the number of collected x rays collected reduces as the number of counts increase. The uncertainty of the collected signal is fully described by Poisson statistics. Increasing the number of x rays collected involves either counting longer or at a higher counting rate. Counting longer means the analysis time increases and may become excessive to get to the desired uncertainty. Instrument drift also becomes an issue. Counting at higher rates has its limitations, which are a function of the detector physics and the detecting electronics. Since the beginning of EPMA analysis, analog electronics have been used to amplify and discriminate the x-ray induced ionizations within the proportional counter. This paper will discuss the use of digital electronics for this purpose. These electronics are similar to that used for energy dispersive analysis of x rays with either Si(Li) or Ge(Li) detectors except that the shaping time constants are much smaller. PMID:27446749

  2. High pressure, high strain rate material strength studies

    Science.gov (United States)

    Remington, B. A.; Arsenlis, A.; Barton, N.; Belof, J.; Cavallo, R.; Maddox, B.; Park, H.-S.; Prisbrey, S.; Rudd, R.; Comley, A.; Meyers, M.; Wark, J.

    2011-10-01

    Constitutive models for material strength are currently being tested at high pressures by comparing 2D simulations with experiments measuring the Rayleigh-Taylor (RT) instability evolution in solid-state samples of vanadium (V), tantalum (Ta), and iron (Fe). The multiscale strength models being tested combine molecular dynamics, dislocation dynamics, and continuum simulations. Our analysis for the V experiments suggests that the material deformation at these conditions falls into the phonon drag regime, whereas for Ta, the deformation resides mainly in the thermal activation regime. Recent Fe-RT experiments suggest perturbation growth about the alpha-epsilon (bcc-hcp) phase transition threshold has been observed. Using the LLNL multiscale models, we decompose the strength as a function of strain rate into its dominant components of thermal activation, phonon drag, and work hardening. We have also developed a dynamic diffraction diagnostic technique to measure strength directly from shock compressed single crystal samples. Finally, recovery experiments allow a comparison of residual dislocation density with predictions from the multiscale model. This work performed under the auspices of the U.S. DoE by LLNL Security, LLC under Contract DE-AC52-07NA27344.

  3. RENAL CLEARANCE AND URINARY EXCRETION OF CIPROFLOXACIN IN GOATS

    Directory of Open Access Journals (Sweden)

    Z. IQBAL, I. JAVED, B. ASLAM, F. MUHAMMAD AND I. U. JAN

    2007-10-01

    Full Text Available The renal clearance and urinary excretion of ciprofloxacin were investigated in eight healthy female goats. In each animal, ciprofloxacin was administered intramuscularly at the rate of 5 mg/kg body weight. Following drug administration, blood and urine samples were collected at different time intervals and analyzed for ciprofloxacin and creatinine. High performance liquid chromatography (HPLC was used to determine the drug concentration in the plasma and urine. The value of diuresis after single administration of ciprofloxacin was 0.073 ± 0.014 ml/min/kg. Mean (± SE values for renal clearance of creatinine and ciprofloxacin were 1.870 ± 0.385 and 0.982 ± 0.166 ml/min/kg, respectively. The ratio between the renal clearance of ciprofloxacin and that of creatinine remained less than one, which was indicative of back diffusion. The mean (± SE value for the cumulative percent of ciprofloxacin dose excreted at 10 hours following its intramuscular administration was 13.03 ± 2.07. Based on these results, it was evident that besides glomerular filtration, renal handling of drug involved back diffusion also. It was concluded that in local goats glomerular filtration rate (GFR was lower than that reported for their foreign counterparts.

  4. Clinical evaluation of amylase-creatinine clearance ratio and amylase isoenzyme clearance in chronic renal failure.

    Science.gov (United States)

    Maeda, M; Otsuki, M; Okano, K; Yamasaki, T; Baba, S

    1981-01-01

    Amylase-creatinine clearance ratio (ACCR) and amylase isoenzyme clearance were determined simultaneously in patients with chronic renal failure. ACCR in patients with compensated renal failure (3.5 +/- 0.4%) was not significantly different from normals (2.6 +/- 0.2%), while that in patients with non-compensated renal failure (6.7 +/- 0.4%) was significantly higher than that in normals. Clearance ratio of pancreatic isoamylase (Amylase-1) relative to creatinine clearance (CAmy . 1/Ccr) in patients with both compensated (5.9 +/- 1.0%) and non-compensated (6.8 +/- 0.4%) renal failure was as high as that in patients with acute pancreatitis (6.6 +/- 0.5%). On the other hand, clearance ratio of salivary isoamylase (Amylase-3) relative to creatinine clearance (CAmy . 3/CCr) in patients with compensated renal failure (1.5 +/- 0.3%) was almost the same as that in normals (2.1 +/- 0.1%), while that in patients with non-compensated renal failure was 5.9 +/- 0.7%, which was significantly higher than that in normals. The present study revealed that elevated ACCR in patients with severely impaired renal function was due to the increase of the clearance ratio for both pancreatic and salivary amylase. These facts suggested that glomerular permeability and tubular reabsorption for pancreatic and salivary amylase might play an important role on ACCR in patients with severely impaired renal function.

  5. High-Rate Capable Floating Strip Micromegas

    CERN Document Server

    Bortfeldt, Jonathan; Biebel, Otmar; Danger, Helge; Flierl, Bernhard; Hertenberger, Ralf; Lösel, Philipp; Moll, Samuel; Parodi, Katia; Rinaldi, Ilaria; Ruschke, Alexander; Zibell, André

    2015-01-01

    We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in high-background environments and at very high particle fluxes up to 60MHz/cm$^2$. Measurement and simulation of the microscopic discharge behavior have demonstrated the excellent discharge tolerance. A floating strip Micromegas with an active area of 48cm$\\times$50cm with 1920 copper anode strips exhibits in 120GeV pion beams a spatial resolution of 50$\\mu$m at detection efficiencies above 95%. Pulse height, spatial resolution and detection efficiency are homogeneous over the detector. Reconstruction of particle track inclination in a single detector plane is discussed, optimum angular resolutions below $5^\\circ$ are observed. Systematic deviations of this $\\mu$TPC-method are fully understood. The reconstruction capabilities for minimum ionizing muons are investigated in a 6.4cm$\\time...

  6. High dose rate brachytherapy source measurement intercomparison.

    Science.gov (United States)

    Poder, Joel; Smith, Ryan L; Shelton, Nikki; Whitaker, May; Butler, Duncan; Haworth, Annette

    2017-06-01

    This work presents a comparison of air kerma rate (AKR) measurements performed by multiple radiotherapy centres for a single HDR (192)Ir source. Two separate groups (consisting of 15 centres) performed AKR measurements at one of two host centres in Australia. Each group travelled to one of the host centres and measured the AKR of a single (192)Ir source using their own equipment and local protocols. Results were compared to the (192)Ir source calibration certificate provided by the manufacturer by means of a ratio of measured to certified AKR. The comparisons showed remarkably consistent results with the maximum deviation in measurement from the decay-corrected source certificate value being 1.1%. The maximum percentage difference between any two measurements was less than 2%. The comparisons demonstrated the consistency of well-chambers used for (192)Ir AKR measurements in Australia, despite the lack of a local calibration service, and served as a valuable focal point for the exchange of ideas and dosimetry methods.

  7. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H;

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... to fall in the sitting position, and fell significantly to 26 +/- 5 ml/min (p less than 0.025) in walking subjects. Absolute proximal tubular reabsorption rate of fluid correspondingly rose from 83 +/- 16 to 92 +/- 15 ml/min (p less than 0.005) and sodium clearance fell from 1.52 +/- 0.81 to 1.00 +/- 0...

  8. Liquid argon calorimeter performance at high rates

    CERN Document Server

    Seifert, F; The ATLAS collaboration

    2012-01-01

    The expected increase of luminosity at HL-LHC by a factor of ten with respect to LHC luminosities has serious consequences for the signal reconstruction, radiation hardness requirements and operations of the ATLAS liquid argon calorimeters in the endcap, respectively forward region. Small modules of each type of calorimeter have been built and exposed to a high intensity proton beam of 50 GeV at IHEP/Protvino. The beam is extracted via the bent crystal technique, offering the unique opportunity to cover intensities ranging from $10^6$ p/s up to $10^{12}$ p/s. This exceeds the deposited energy per time expected at HL-LHC by more than a factor of 100. The correlation between beam intensity and the read-out signal has been studied. The data show clear indications of pulse shape distortion due to the high ionization build-up, in agreement with MC expectations. This is also confirmed from the dependence of the HV currents on beam intensity.

  9. Liquid Argon Calorimeter performance at High Rates

    CERN Document Server

    Seifert, F; The ATLAS collaboration

    2013-01-01

    The expected increase of luminosity at HL-LHC by a factor of ten with respect to LHC luminosities has serious consequences for the signal reconstruction, radiation hardness requirements and operations of the ATLAS liquid argon calorimeters in the endcap, respectively forward region. Small modules of each type of calorimeter have been built and exposed to a high intensity proton beam of 50 GeV at IHEP/Protvino. The beam is extracted via the bent crystal technique, offering the unique opportunity to cover intensities ranging from $10^6$ p/s up to $3\\cdot10^{11}$ p/s. This exceeds the deposited energy per time expected at HL-LHC by more than a factor of 100. The correlation between beam intensity and the read-out signal has been studied. The data show clear indications of pulse shape distortion due to the high ionization build-up, in agreement with MC expectations. This is also confirmed from the dependence of the HV currents on beam intensity.

  10. High-deposition-rate ceramics synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Allendorf, M.D.; Osterheld, T.H.; Outka, D.A. [Sandia National Laboratories, Livermore, CA (United States)] [and others

    1995-05-01

    Parallel experimental and computational investigations are conducted in this project to develop validated numerical models of ceramic synthesis processes. Experiments are conducted in the High-Temperature Materials Synthesis Laboratory in Sandia`s Combustion Research Facility. A high-temperature flow reactor that can accommodate small preforms (1-3 cm diameter) generates conditions under which deposition can be observed, with flexibility to vary both deposition temperature (up to 1500 K) and pressure (as low as 10 torr). Both mass spectrometric and laser diagnostic probes are available to provide measurements of gas-phase compositions. Experiments using surface analytical techniques are also applied to characterize important processes occuring on the deposit surface. Computational tools developed through extensive research in the combustion field are employed to simulate the chemically reacting flows present in typical industrial reactors. These include the CHEMKIN and Surface-CHEMKIN suites of codes, which permit facile development of complex reaction mechanisms and vastly simplify the implementation of multi-component transport and thermodynamics. Quantum chemistry codes are also used to estimate thermodynamic and kinetic data for species and reactions for which this information is unavailable.

  11. Alternatives to percussion and postural drainage. A review of mucus clearance therapies: percussion and postural drainage, autogenic drainage, positive expiratory pressure, flutter valve, intrapulmonary percussive ventilation, and high-frequency chest compression with the ThAIRapy Vest.

    Science.gov (United States)

    Langenderfer, B

    1998-01-01

    The purpose of this article is to review published studies on the efficacy of old and new mucus clearance techniques and to develop recommendations for different groups of patients. Mucus clearance is a problem in cystic fibrosis, bronchiectasis, and many other pulmonary conditions. Percussion and postural drainage (P & PD) was the traditional method of facilitating mucus clearance, but the many hazards and contraindications along with the onerous nature and resultant poor patient compliance of this procedure have led to the development of alternative therapies. Research studies with cystic fibrosis patients support the efficacy of P & PD in patients who can tolerate it. However, equivalent sputum production can be accomplished with autogenic drainage, positive expiratory pressure, and Flutter valve therapy without the assistance of another caregiver, as long as the patient has the motivation, breath control, and neuromuscular function to perform these modalities. The Intrapulmonary Percussive Ventilation device and high-frequency chest compression with the ThAIRapy vest involve more elaborate and expensive equipment, yet these devices provide mucus clearance assistance to patients who lack the ability to perform the simpler techniques. Both mechanized modalities promote independence and self-care in the patient, and the effectiveness of both has been supported by the limited research published to date. Which alternative to recommend depends on the ability, motivation, preference, needs, and resources of each patient.

  12. High rate fabrication of compression molded components

    Energy Technology Data Exchange (ETDEWEB)

    Matsen, Marc R.; Negley, Mark A.; Dykstra, William C.; Smith, Glen L.; Miller, Robert J.

    2016-04-19

    A method for fabricating a thermoplastic composite component comprises inductively heating a thermoplastic pre-form with a first induction coil by inducing current to flow in susceptor wires disposed throughout the pre-form, inductively heating smart susceptors in a molding tool to a leveling temperature with a second induction coil by applying a high-strength magnetic field having a magnetic flux that passes through surfaces of the smart susceptors, shaping the magnetic flux that passes through surfaces of the smart susceptors to flow substantially parallel to a molding surface of the smart susceptors, placing the heated pre-form between the heated smart susceptors; and applying molding pressure to the pre-form to form the composite component.

  13. The modern high rate digital cassette recorder

    Science.gov (United States)

    Clemow, Martin

    1993-01-01

    The magnetic tape recorder has played an essential role in the capture and storage of instrumentation data for more than thirty years. During this time, data recording technology has steadily progressed to meet user demands for more channels, wider bandwidths, and longer recording durations. When acquisition and processing moved from analog to digital techniques, so recorder design followed suit. Milestones marking the evolution of the data recorder through these various stages - multi-track analog, high density longitudinal digital, and more recently rotary digital - have often represented important breakthroughs in the handling of ever-greater quantities of data. Throughout this period there has been a very clear line of demarcation between data storage methods in the 'instrumentation world' on the one hand and the 'computer peripheral world' on the other. This is despite the fact that instrumentation data, whether analog or digital at the point of acquisition, is now likely to be processed on a digital computer at some stage. Regardless of whether the processing device is a small personal computer, a workstation, or the largest supercomputer, system integrators have traditionally been faced with the same basic problem - how to interface what is essentially a manually controlled, continuously running device (the tape recorder) into the fast start/stop computer environment without resorting to an excessive amount of complex custom interfacing and performance compromise. The increasing availability of affordable high power processing equipment throughout the scientific world is forcing recorder manufacturers to make their latest and perhaps most important breakthrough - the computer-friendly data recorder. The operating characteristics of such recorders are discussed and the resultant impact on both data acquisition and data analysis elements of system configuration are considered.

  14. Glomerular filtration rate measured by 51Cr-EDTA clearance: evaluation of captopril-induced changes in hypertensive patients with and without renal artery stenosis

    Directory of Open Access Journals (Sweden)

    Anna Alice Rolim Chaves

    2010-01-01

    Full Text Available INTRODUCTION: Renal artery stenosis can lead to renovascular hypertension; however, the detection of stenosis alone does not guarantee the presence of renovascular hypertension. Renovascular hypertension depends on activation of the renin-angiotensin system, which can be detected by functional tests such as captopril renal scintigraphy. A method that allows direct measurement of the baseline and post-captopril glomerular filtration rate using chromium-51 labeled ethylenediamine tetraacetic acid (51Cr-EDTA could add valuable information to the investigation of hypertensive patients with renal artery stenosis. The purposes of this study were to create a protocol to measure the baseline and post-captopril glomerular filtration rate using 51Cr-EDTA, and to verify whether changes in the glomerular filtration rate permit differentiation between hypertensive patients with and without renal artery stenosis. METHODS: This prospective study included 41 consecutive patients with poorly controlled severe hypertension. All patients had undergone a radiological investigation of renal artery stenosis within the month prior to their inclusion. The patients were divided into two groups: patients with (n=21 and without renal artery stenosis, (n=20. In vitro glomerular filtration rate analysis (51Cr-EDTA and 99mTc-DMSA scintigraphy were performed before and after captopril administration in all patients. RESULTS: The mean baseline glomerular filtration rate was 48.6±21.8 ml/kg/1.73 m² in the group wuth renal artery stenosis, which was significantly lower than the GFR of 65.1±28.7 ml/kg/1.73m² in the group without renal artery stenosis (p=0.04. Captopril induced a significant reduction of the glomerular filtration rate in the group with renal artery stenosis (to 32.6±14.8 ml/kg/1.73m², p=0.001 and an insignificant change in the group without RAS (to 62.2±23.6 ml/kg/1.73m², p=0.68. Scintigraphy with technetium-99m dimercapto-succinic acid (DMSA did not show

  15. Glomerular Filtration Rate Measured by 51Cr-EDTA Clearance: Evaluation of Captopril-Induced Changes in Hypertensive Patients with and without Renal Artery Stenosis

    Science.gov (United States)

    Chaves, Anna Alice Rolim; Buchpiguel, Carlos Alberto; Praxedes, Jose Nery; Bortolotto, Luiz Aparecido; Sapienza, Marcelo Tatit

    2010-01-01

    INTRODUCTION: Renal artery stenosis can lead to renovascular hypertension; however, the detection of stenosis alone does not guarantee the presence of renovascular hypertension. Renovascular hypertension depends on activation of the renin-angiotensin system, which can be detected by functional tests such as captopril renal scintigraphy. A method that allows direct measurement of the baseline and post-captopril glomerular filtration rate using chromium-51 labeled ethylenediamine tetraacetic acid (51Cr-EDTA) could add valuable information to the investigation of hypertensive patients with renal artery stenosis. The purposes of this study were to create a protocol to measure the baseline and post-captopril glomerular filtration rate using 51Cr-EDTA, and to verify whether changes in the glomerular filtration rate permit differentiation between hypertensive patients with and without renal artery stenosis. METHODS: This prospective study included 41 consecutive patients with poorly controlled severe hypertension. All patients had undergone a radiological investigation of renal artery stenosis within the month prior to their inclusion. The patients were divided into two groups: patients with (n=21) and without renal artery stenosis, (n=20). In vitro glomerular filtration rate analysis (51Cr-EDTA) and 99mTc-DMSA scintigraphy were performed before and after captopril administration in all patients. RESULTS: The mean baseline glomerular filtration rate was 48.6±21.8 ml/kg/1.73 m2 in the group wuth renal artery stenosis, which was significantly lower than the GFR of 65.1±28.7 ml/kg/1.73m2 in the group without renal artery stenosis (p=0.04). Captopril induced a significant reduction of the glomerular filtration rate in the group with renal artery stenosis (to 32.6±14.8 ml/ kg/1.73m2, p=0.001) and an insignificant change in the group without RAS (to 62.2±23.6 ml/kg/1.73m2, p=0.68). Scintigraphy with technetium-99m dimercapto-succinic acid (DMSA) did not show significant

  16. Glomerular filtration rate measured by {sup 51}Cr-EDTA clearance: evaluation of captopril-induced changes in hypertensive patients with and without renal artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, Anna Alice Rolim; Buchpiguel, Carlos Alberto; Praxedes, Jose Nery; Bortolotto, Luiz Aparecido; Sapienza, Marcelo Tatit, E-mail: annaalice100@yahoo.com.b [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Dept. de Neurologia

    2010-07-01

    Introduction: renal artery stenosis can lead to renovascular hypertension; however, the detection of stenosis alone does not guarantee the presence of renovascular hypertension. Renovascular hypertension depends on activation of the renin-angiotensin system, which can be detected by functional tests such as captopril renal scintigraphy. A method that allows direct measurement of the baseline and post-captopril glomerular filtration rate using chromium-51 labeled ethylenediamine tetraacetic acid ({sup 51}Cr-EDTA) could add valuable information to the investigation of hypertensive patients with renal artery stenosis. The purposes of this study were to create a protocol to measure the baseline and post-captopril glomerular filtration rate using {sup 51}Cr-EDTA, and to verify whether changes in the glomerular filtration rate permit differentiation between hypertensive patients with and without renal artery stenosis. Methods: this prospective study included 41 consecutive patients with poorly controlled severe hypertension. All patients had undergone a radiological investigation of renal artery stenosis within the month prior to their inclusion. The patients were divided into two groups: patients with (n=21) and without renal artery stenosis, (n=20). In vitro glomerular filtration rate analysis ({sup 51}Cr-EDTA) and {sup 99m}Tc-DMSA scintigraphy were performed before and after captopril administration in all patients. Results: the mean baseline glomerular filtration rate was 48.6+-21.8 ml/kg/1.73 m{sup 2} in the group with renal artery stenosis, which was significantly lower than the GFR of 65.1+-28.7 ml/kg/1.73m{sup 2} in the group without renal artery stenosis (p=0.04). Captopril induced a significant reduction of the glomerular filtration rate in the group with renal artery stenosis (to 32.6+-14.8 ml/kg/1.73m{sup 2}, p=0.001) and an insignificant change in the group without RAS (to 62.2+-23.6 ml/kg/1.73m{sup 2}, p=0.68). Scintigraphy with technetium-99m dimercapto

  17. High data rate optical transceiver terminal

    Science.gov (United States)

    Clarke, E. S.

    1973-01-01

    The objectives of this study were: (1) to design a 400 Mbps optical transceiver terminal to operate from a high-altitude balloon-borne platform in order to permit the quantitative evaluation of a space-qualifiable optical communications system design, (2) to design an atmospheric propagation experiment to operate in conjunction with the terminal to measure the degrading effects of the atmosphere on the links, and (3) to design typical optical communications experiments for space-borne laboratories in the 1980-1990 time frame. As a result of the study, a transceiver package has been configured for demonstration flights during late 1974. The transceiver contains a 400 Mbps transmitter, a 400 Mbps receiver, and acquisition and tracking receivers. The transmitter is a Nd:YAG, 200 Mhz, mode-locked, CW, diode-pumped laser operating at 1.06 um requiring 50 mW for 6 db margin. It will be designed to implement Pulse Quaternary Modulation (PQM). The 400 Mbps receiver utilizes a Dynamic Crossed-Field Photomultiplier (DCFP) detector. The acquisition receiver is a Quadrant Photomultiplier Tube (QPMT) and receives a 400 Mbps signal chopped at 0.1 Mhz.

  18. Transcapillary escape rate and relative metabolic clearance of glycated and non-glycated albumin in type 1 (insulin-dependent) diabetes mellitus

    DEFF Research Database (Denmark)

    Bent-Hansen, L; Feldt-Rasmussen, B; Kverneland, A;

    1987-01-01

    The transcapillary escape rate and relative plasma disappearance of glycated and non-glycated albumin were measured in 25 male Type 1 (insulin-dependent) diabetic patients using a double tracer technique. The patients were divided into three groups on the basis of their urinary albumin excretion......: group 1, normal albumin excretion (less than 30 mg/24 h) (n = 8); group 2, microalbuminuria (30-300 mg/24 h) (n = 9); and group 3, clinical nephropathy (greater than 300 mg/24 h) (n = 8). Six male age-matched non-diabetic persons served as control subjects. The transcapillary escape rate of glycated...... albumin was similar in group 1 and control subjects (4.7 +/- 2.1 versus 5.1 +/- 1.7%), but significantly increased in group 2 (7.0 +/- 1.7%, p less than 0.05) and in group 3 (7.9 +/- 3.1%, p less than 0.05). The transcapillary escape rate of glycated albumin was slightly lower than that of non-glycated...

  19. The Effect of Minimum Wage Rates on High School Completion

    Science.gov (United States)

    Warren, John Robert; Hamrock, Caitlin

    2010-01-01

    Does increasing the minimum wage reduce the high school completion rate? Previous research has suffered from (1. narrow time horizons, (2. potentially inadequate measures of states' high school completion rates, and (3. potentially inadequate measures of minimum wage rates. Overcoming each of these limitations, we analyze the impact of changes in…

  20. High regression rate, high density hybrid fuels Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR program will investigate high energy density novel nanofuels combined with high density binders for use with an N2O oxidizer. Terves has developed...

  1. Hepatic and Extrahepatic Insulin Clearance Are Differentially Regulated: Results From a Novel Model-Based Analysis of Intravenous Glucose Tolerance Data.

    Science.gov (United States)

    Polidori, David C; Bergman, Richard N; Chung, Stephanie T; Sumner, Anne E

    2016-06-01

    Insulin clearance is a highly variable and important factor that affects circulating insulin concentrations. We developed a novel model-based method to estimate both hepatic and extrahepatic insulin clearance using plasma insulin and C-peptide profiles obtained from the insulin-modified frequently sampled intravenous glucose tolerance test. Data from 100 African immigrants without diabetes (mean age 38 years, body weight 81.7 kg, fasting plasma glucose concentration 83 mg/dL, and fasting insulin concentration 37 pmol/L) were used. Endogenous insulin secretion (calculated by C-peptide deconvolution) and insulin infusion rates were used as inputs to a new two-compartment model of insulin kinetics and hepatic and extrahepatic clearance parameters were estimated. Good agreement between modeled and measured plasma insulin profiles was observed (mean normalized root mean square error 6.8%), and considerable intersubject variability in parameters of insulin clearance among individuals was identified (the mean [interquartile range] for hepatic extraction was 25.8% [32.7%], and for extrahepatic insulin clearance was 20.7 mL/kg/min [11.7 mL/kg/min]). Parameters of insulin clearance were correlated with measures of insulin sensitivity and acute insulin response to glucose. The method described appears promising for future research aimed at characterizing variability in insulin clearance and the mechanisms involved in the regulation of insulin clearance.

  2. Centrifugal compressor tip clearance and impeller flow

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari [Laboratory of Fluid Dynamics, LUT School of Energy Systems, Lappeenranta University of Technology, Lappeenranta (Finland); Engeda, Abraham [Turbomachinery Laboratory, Dept. of Mechanical Engineering, Michigan State University, East Lansing (United States)

    2016-11-15

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease.

  3. A comparison of GFR by modified gates method with measured creatinine clearance rate (CCR) & MDRD formula based estimation in type 2 diabetic subjects with nephropathy.

    Science.gov (United States)

    Haque, M F; Iqbal, M M; Ahmed, Z; Sultan, T; Rahman, M; Quddus, S; Rahman, M Q; Ahmed, N N

    2013-10-01

    Accurate estimation of the glomerular filtration rate (GFR) is essential for the evaluation of patient with chronic kidney disease (CKD). The present study was a comparison between modified gates GFR with laboratory measured CCR & MDRD formula based estimated GFR method. Pre-diagnosed 180 diabetic nephropathy patients were selected. All the time of evaluation the blood glucose of the patients were controlled and serum creatinine was stable. Then CCR was done and GFR was estimated by Modified Gates method & MDRD method. All the patients were categorized in 5 stages of CKD. They were matched for age, BMI, blood pressure, duration of diabetes, the blood sugar and HbA1C levels. The Gates GFR in stage-2 (70±13) & stage-3 (48±12) was closer with MDRD in stage-2 (77±8) and stage 3 (43±7). The CCR is closer in stage-1 (110±52) & stage-4 (30±10) with MDRD in stage-1 (112±13) and stage-4 (21±4). Association study showed MDRD GFR had highest correlation with Gates GFR (r=0.86; pGFR) in different methods varied significantly between each other at different stages of chronic kidney disease (CKD) in type 2 diabetic nephropathy subjects.

  4. Strain rate effect in high-speed wire drawing process

    Science.gov (United States)

    He, S.; Van Houtte, P.; Van Bael, A.; Mei, F.; Sarban, A.; Boesman, P.; Galvez, F.; Atienza, J. M.

    2002-05-01

    This paper presents a study on the strain rate effect during high-speed wire drawing process by means of finite element simulation. Based on the quasistatic stresses obtained by normal tensile tests and dynamic stresses at high strain rates by split Hopkinson pressure bar tests, the wire drawing process was simulated for low carbon steel and high carbon steel. The results show that both the deformation process and the final properties of drawn wires are influenced by the strain rate.

  5. High-Rate Strong-Signal Quantum Cryptography

    Science.gov (United States)

    Yuen, Horace P.

    1996-01-01

    Several quantum cryptosystems utilizing different kinds of nonclassical lights, which can accommodate high intensity fields and high data rate, are described. However, they are all sensitive to loss and both the high rate and the strong-signal character rapidly disappear. A squeezed light homodyne detection scheme is proposed which, with present-day technology, leads to more than two orders of magnitude data rate improvement over other current experimental systems for moderate loss.

  6. Effect of blood flow rate on internal filtration in a high-flux dialyzer with polysulfone membrane.

    Science.gov (United States)

    Sakiyama, Ryoichi; Ishimori, Isamu; Akiba, Takashi; Mineshima, Michio

    2012-09-01

    Internal filtration/backfiltration (IF/BF) of a dialyzer depends on several parameters. This study evaluated the effect of the blood flow rate (Q (B)) on the internal filtration flow rate (Q (IF)) measured using Doppler ultrasonography for a high-flux dialyzer with a polysulfone membrane, APS-15E. In an in vitro study, bovine blood was circulated through the dialyzer, at a Q (B) of 100-350 mL/min. The clearances (CL) of creatinine, β(2)-microglobulin, and α(1)-microglobulin were then investigated. Q (IF) increased with the Q (B) value. A good correlation was obtained between Q (IF) and the pressure difference between the pressures at the inlet of the blood compartment and the pressure at the outlet of the dialysate compartment. The creatinine CL values strongly depended on Q (B) because molecular diffusion was dominant. The β(2)-microglobulin CL also depended on Q (B), because its removal rate seemed to be affected by both diffusive and convective transport caused by the IF/BF. An extremely low CL value was obtained for α(1)-microglobulin because of its low diffusivity and membrane fouling induced by proteins plugging the membrane. In conclusion, the IF/BF in the dialyzer strongly depends on Q (B). Furthermore, the dependence of the solute clearance on Q (B) decreased with increasing molecular size of the solute because of the decrease in diffusivity through the membrane.

  7. Diffusive clearance of small and middle-sized molecules in combined dialyzer flow configurations.

    Science.gov (United States)

    Eloot, S; De Vos, J Y; Hombrouckx, R; Verdonck, P

    2004-03-01

    Clearance of low (LMW) and middle molecular weight (MMW) solutes was investigated in vitro for different dialyzer configurations and mutual flow directions. Single pass tests were performed with two low flux Fresenius F6HPS hemodialyzers placed in series (12 tests) and in parallel (6 tests), and results were compared with those for one single dialyzer (2 tests). Either high concentrated (45mS/cm) bicarbonate dialysis fluid (surrogate LMW) or trisodiumphosphate (surrogate MMW) concentration (31mS/cm) was used as blood substitution fluid. Standard blood and dialysate flows of 250 and 500ml/min, respectively, were prescribed. Clearance was derived from conductivity measurements in blood and dialysate compartment, correcting for the overall ultrafiltration rate of 0.1-0.5l/h. In a single dialyzer, changing the counter current flow to co-current deteriorates diffusive clearance by 14% (LMW) and 18% (MMW). Compared to one single dialyzer using counter current flow, clearance increases by 3 to 8% (LMW) and by 15 to 18% (MMW) using two dialyzers in parallel and in series, respectively. As a consequence, the benefit by using a second dialyzer is more prominent for larger molecules. Moreover, pressure profiles drawn for the different configurations show the impact of limited convection on diffusive clearance.

  8. High Blood Pressure Rates Have Doubled Worldwide Since 1975

    Science.gov (United States)

    ... https://medlineplus.gov/news/fullstory_162069.html High Blood Pressure Rates Have Doubled Worldwide Since 1975 Most of ... News) -- The number of people worldwide with high blood pressure has nearly doubled over the past 40 years, ...

  9. Modeling of deposition and clearance of inhaled Ni compounds in the human lung.

    Science.gov (United States)

    Hsieh, T H; Yu, C P; Oberdörster, G

    1999-08-01

    By extrapolation from the rat study, a mathematical model of deposition, clearance, and retention kinetics for inhaled Ni compounds (high-temperature (green) NiO, Ni(3)S(2), and NiSO(4). 6H(2)O) in the alveolar region of the human lung has been developed. For human deposition, an updated version of an earlier model (C. P. Yu and C. K. Diu, 1982, Am. Ind. Hyg. Assoc. J.) was used in this study. Because of the profound differences in physiological and ventilation conditions between humans and rats, humans were found to have a higher alveolar deposition fraction than rats when exposed to the same Ni compounds. However, when normalized to the lung weight, the deposition rate per gram of lung in humans is much smaller than in rats. In the development of a clearance model, a single-compartment model in the lung was used and a general assumption was made that the clearance of the insoluble and moderately soluble nickel compounds (high-temperature (green) NiO and Ni(3)S(2), respectively) depends highly on the volume of retained particles in the lungs. As for the highly soluble nickel compound (NiSO(4). 6H(2)O), the clearance rate coefficient was assumed to depend on the retained particle mass and total alveolar surface. These clearance rate coefficients were extrapolated from the rat data. The retention half-times for high temperature (green) NiO and Ni(3)S(2) particles in humans were found to be much longer than in rats, whereas the retention half-time for NiSO(4). 6H(2)O particles was about the same for both species. The lung burden results in humans for various exposure conditions are predicted and the equivalent exposure concentrations for humans which lead to the same lung burdens found in rats were calculated.

  10. High-shear-rate capillary viscometer for inkjet inks

    Energy Technology Data Exchange (ETDEWEB)

    Wang Xi [FUJIFILM Dimatix, Inc., Lebanon, New Hampshire 03766 (United States); Carr, Wallace W.; Bucknall, David G. [School of Polymer, Textile, and Fiber Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Morris, Jeffrey F. [Department of Chemical Engineering and Benjamin Levich Institute for Physico-Chemical Hydrodynamics, City College of New York, New York, New York 10031 (United States)

    2010-06-15

    A capillary viscometer developed to measure the apparent shear viscosity of inkjet inks at high apparent shear rates encountered during inkjet printing is described. By using the Weissenberg-Rabinowitsch equation, true shear viscosity versus true shear rate is obtained. The device is comprised of a constant-flow generator, a static pressure monitoring device, a high precision submillimeter capillary die, and a high stiffness flow path. The system, which is calibrated using standard Newtonian low-viscosity silicone oil, can be easily operated and maintained. Results for measurement of the shear-rate-dependent viscosity of carbon-black pigmented water-based inkjet inks at shear rates up to 2x10{sup 5} s{sup -1} are discussed. The Cross model was found to closely fit the experimental data. Inkjet ink samples with similar low-shear-rate viscosities exhibited significantly different shear viscosities at high shear rates depending on particle loading.

  11. Circuit and interconnect design for high bit-rate applications

    NARCIS (Netherlands)

    Veenstra, H.

    2006-01-01

    This thesis presents circuit and interconnect design techniques and design flows that address the most difficult and ill-defined aspects of the design of ICs for high bit-rate applications. Bottlenecks in interconnect design, circuit design and on-chip signal distribution for high bit-rate applicati

  12. High Graduate Unemployment Rate and Taiwanese Undergraduate Education

    Science.gov (United States)

    Wu, Chih-Chun

    2011-01-01

    An expansion in higher education in combination with the recent global economic recession has resulted in a high college graduate unemployment rate in Taiwan. This study investigates how the high unemployment rate and financial constraints caused by economic cutbacks have shaped undergraduates' class choices, job needs, and future income…

  13. HIGH-RATE DISINFECTION TECHNIQUES FOR COMBIND SEWER OVERFLOW

    Science.gov (United States)

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH )...

  14. pH modulation and salivary sugar clearance of different chocolates in children: A randomized clinical trial

    Directory of Open Access Journals (Sweden)

    SVSG Nirmala

    2016-01-01

    Full Text Available Background: Sugars that occur naturally in foods and those added in processed foods may act as the source for fermentable carbohydrates and may initiate caries process. Among all the foods consumed by children, chocolates form an important constituent. A wide variety of chocolates are available in the Indian market and very few studies have compared their acidogenicity and salivary sugar clearance. Objectives: To compare the acidogenicity and salivary sugar clearance of 6 different commercially available chocolates in the Indian market. Materials and Methods: Thirty subjects aged 10-15 years were selected randomly from one of the available public schools in Nellore city. Six commercially available chocolates in the Indian market were divided into three groups, unfilled (dark and milk chocolate, filled (wafer and fruit and nuts chocolate, and candy (hard milk and mango-flavored candy groups. Plaque pH values and salivary sugar clearance rates are assessed at baseline, 5, 10, 15, 20, and 30 min after consumption. All the data obtained were statistically evaluated using independent sample t-test and one-way ANOVA for multiple group comparisons. Results: Mango-flavored candy had maximum fall in plaque pH and least fall in plaque pH was recorded with milk chocolate. Fruit and nuts chocolate had a maximum clearance of salivary sugar and least fall in the salivary sugar clearance was recorded with dark chocolate. When the plaque pH and salivary sugar clearance of all the chocolates were assessed, it was seen that the values were statistically significant at all the time intervals (P < 0.05. Conclusion: Dark chocolate had a high fall in pH and milk chocolate had low salivary sugar clearance which signifies that unfilled chocolates are more cariogenic than other chocolates. Even though mango-flavored candy had maximum fall in plaque pH, its salivary sugar clearance was high.

  15. 32 CFR 154.48 - Issuing clearance.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Issuing clearance. 154.48 Section 154.48... PERSONNEL SECURITY PROGRAM REGULATION Issuing Clearance and Granting Access § 154.48 Issuing clearance. (a... personnel security clearance in the DCII (see § 154.43). A record of the clearance issued shall also...

  16. 24 CFR 35.1340 - Clearance.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Clearance. 35.1340 Section 35.1340... Hazard Evaluation and Hazard Reduction Activities § 35.1340 Clearance. Clearance examinations required... provisions of this section. (a) Clearance following abatement. Clearance examinations performed...

  17. Miniature High Stability High Temperature Space Rated Blackbody Radiance Source

    Science.gov (United States)

    Jones, J. A.; Beswick, A. G.

    1987-09-01

    This paper presents the design and test performance of a conical cavity type blackbody radiance source that will meet the requirements of the Halogen Occultation Experiment (HALOE) on the NASA Upper Atmospheric Research Satellite program (UARS). Since a radiance source meeting the requirements of this experiment was unavailable in the commercial market, a development effort was undertaken by the HALOE Project. The blackbody radiance source operates in vacuum at 1300 K + 0.5 K over any 15-minute interval, uses less than 7.5 watts of power, maintains a 49°C outer case temperature, and fits within the 2.5 x 2.5 x 3.0 inch envelope allocated inside the HALOE instrument. Also, the unit operates in air, during ground testing of the HALOE instrument, where it uses 17 watts of power with an outer case temperature of 66°C. The thrust of this design effort was to minimize the heat losses, in order to keep the power usage under 7.5 watts, and to minimize the amount of silica in the materials. Silica in the presence of the platinum heater winding used in this design would cause the platinum to erode, changing the operating temperature set-point. The design required the development of fabrication techniques which would provide very small, close tolerance parts from extremely difficult-to-machine materials. Also, a space rated ceramic core and unique, low thermal conductance, ceramic-to-metal joint was developed, tested and incorporated in this design. The completed flight qualification hardware has undergone performance, environmental and life testing. The design configuration and test results are discussed in detail in this paper.

  18. Allometric scaling for predicting human clearance of bisphenol A

    Energy Technology Data Exchange (ETDEWEB)

    Collet, Séverine H., E-mail: s.collet@envt.fr; Picard-Hagen, Nicole, E-mail: n.hagen-picard@envt.fr; Lacroix, Marlène Z., E-mail: m.lacroix@envt.fr; Puel, Sylvie, E-mail: s.puel@envt.fr; Viguié, Catherine, E-mail: c.viguie@envt.fr; Bousquet-Melou, Alain, E-mail: a.bousquet-Melou@envt.fr; Toutain, Pierre-Louis, E-mail: pltoutain@wanadoo.fr; Gayrard, Véronique, E-mail: v.gayrard@envt.fr

    2015-05-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min.

  19. Reforming Customs Clearance in Pakistan

    OpenAIRE

    Ahmad, Manzoor

    2010-01-01

    Simple, fast, transparent customs clearance procedures encourage trade-and the resulting tariffs and related taxes raise government revenue and stimulate economic development. After outsourcing failed to make customs more efficient or increase revenue, in 2002 Pakistan began pursuing a modern single window system for customs clearance. In 2005 the system was introduced at the port of Karac...

  20. Aerial Refueling Clearance Initiation Request

    Science.gov (United States)

    2016-07-14

    fund sharing options.................................................................................. 18 3.12 ATP 3.3.4.2...publication of the original document and its eventual publication in ATP -56 (B). Workgroup 5 spent several Workgroup/JSB sessions reviewing and updating...Clearance Compatibility Assessment Checklist. 21 Aug 2014 ATP 3.3.4.2 SRD 1 - Guide to Obtaining AAR Refuelling Clearances & Compatibility Certification

  1. CSF clearance in Alzheimer Disease measured with dynamic PET.

    Science.gov (United States)

    de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry

    2017-03-16

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer's disease (AD) comes from primarily from rodent models. However, unlike rodents where predominant extra-cranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Using dynamic Positron Emission Tomography (PET) with (18)F-THK5117 a tracer for tau pathology, the ventricular CSF time activity was used as a biomarker for CSF clearance. We tested three hypotheses: 1. Extra-cranial CSF is detected at the superior turbinates; 2. CSF clearance is reduced in AD; and 3. CSF clearance is inversely associated with amyloid deposition. Methods: 15 subjects, 8 with AD and 7 normal control volunteers were examined with (18)F-THK5117. 10 subjects additionally received (11)C-PiB PET scans and 8 were PiB positive. Ventricular time activity curves (TAC) of (18)F-THK5117 were used to identify highly correlated TAC from extra-cranial voxels. Results: For all subjects, the greatest density of CSF positive extra-cranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinates CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases.

  2. Are high real interest rates bad for world economic growth?

    OpenAIRE

    1991-01-01

    There is a conventional perception that high real interest rates are bad for economic growth. However, the authors show that close examination of the experience over the last 40 years undermines the existence of such a relationship. For much of the 1950-79 period, expost real interest rates were less than the growth rate of income in the major economies, whereas the 1980s were a period of rapid growth in the world economy that coincided withunprecedentedly high real interest rates. The author...

  3. Effect of different levels of continuous positive airway pressure on the 99mTc-DTPA lung clearance

    Directory of Open Access Journals (Sweden)

    Dulciane Nunes Paiva

    2014-04-01

    Full Text Available Backgound and Objectives: Positive airway pressure continues (CPAP produces significant hemodynamic changes that may influence the variability of breathing pattern and heart rate, acting as an additional therapy to prevent atelectasis and to combat hypoxia. The rate of inhaled 99 m Technetiumdiethylenetriaminepentaacetic acid (99mTc-DTPA, along with changes in the lung epithelium cause an increase in the rate of clearance of this compound. The aim of this study was evaluate the pulmonary clearance rate of 99mTechnetium Diethylenetriaminepentaacetic acid (99mTc-DTPA through the use of different levels of CPAP. Methods: It was a quasi-experimental study involving 17 healthy individuals with normal lung functional. 99mTc-DTPA, as aerosol, was nebulized for 3 minutes with the individual in a sitting position. The pulmonary clearance rate was assessed through pulmonary scintigraphy under spontaneous breathing and under 20 and 10 cmH2 O CPAP in the sitting position. The clearance rate was expressed as the half-time (T½ that is the time for the activity to decrease to 50% of the peak value. Results: 20 cmH2 O CPAP produced significant reduction of the T½ of 99mTc-DTPA in the sitting position (p=0.005. However, 10 cmH2 O CPAP did not alter the T½ of DTPA in the same positions. Conclusion: High levels of continuos positive pressure in normal lungs resulted in faster 99mTc-DTPA clearance moreover, 10 cmH2 O did not alter its clearance rate. KEYWORDS: Noninvasive ventilation. Technetium Tc 99m Pentetate. Radionuclide Imaging.

  4. High Strain Rate Compressive Tests on Woven Graphite Epoxy Composites

    Science.gov (United States)

    Allazadeh, Mohammad Reza; Wosu, Sylvanus N.

    2011-08-01

    The behavior of composite materials may be different when they are subjected to high strain rate load. Penetrating split Hopkinson pressure bar (P-SHPB) is a method to impose high strain rate on specimen in the laboratory experiments. This research work studied the response of the thin circular shape specimens, made out of woven graphite epoxy composites, to high strain rate impact load. The stress-strain relationships and behavior of the specimens were investigated during the compressive dynamic tests for strain rates as high as 3200 s-1. One dimensional analysis was deployed for analytical calculations since the experiments fulfilled the ratio of diameter to length of bars condition in impact load experiments. The mechanics of dynamic failure was studied and the results showed the factors which govern the failure mode in high strain deformation via absorbed energy by the specimen. In this paper, the relation of particle velocity with perforation depth was discussed for woven graphite epoxy specimens.

  5. pH modulation and salivary sugar clearance of different chocolates in children: A randomized clinical trial.

    Science.gov (United States)

    Nirmala, Svsg; Quadar, Mohammed Akhil; Veluru, Sindhuri

    2016-01-01

    Sugars that occur naturally in foods and those added in processed foods may act as the source for fermentable carbohydrates and may initiate caries process. Among all the foods consumed by children, chocolates form an important constituent. A wide variety of chocolates are available in the Indian market and very few studies have compared their acidogenicity and salivary sugar clearance. To compare the acidogenicity and salivary sugar clearance of 6 different commercially available chocolates in the Indian market. Thirty subjects aged 10-15 years were selected randomly from one of the available public schools in Nellore city. Six commercially available chocolates in the Indian market were divided into three groups, unfilled (dark and milk chocolate), filled (wafer and fruit and nuts chocolate), and candy (hard milk and mango-flavored candy) groups. Plaque pH values and salivary sugar clearance rates are assessed at baseline, 5, 10, 15, 20, and 30 min after consumption. All the data obtained were statistically evaluated using independent sample t-test and one-way ANOVA for multiple group comparisons. Mango-flavored candy had maximum fall in plaque pH and least fall in plaque pH was recorded with milk chocolate. Fruit and nuts chocolate had a maximum clearance of salivary sugar and least fall in the salivary sugar clearance was recorded with dark chocolate. When the plaque pH and salivary sugar clearance of all the chocolates were assessed, it was seen that the values were statistically significant at all the time intervals (P sugar clearance which signifies that unfilled chocolates are more cariogenic than other chocolates. Even though mango-flavored candy had maximum fall in plaque pH, its salivary sugar clearance was high.

  6. Quantum data locking for high-rate private communication

    Science.gov (United States)

    Lupo, Cosmo; Lloyd, Seth

    2015-03-01

    We show that, if the accessible information is used as a security quantifier, quantum channels with a certain symmetry can convey private messages at a tremendously high rate, as high as less than one bit below the rate of non-private classical communication. This result is obtained by exploiting the quantum data locking effect. The price to pay to achieve such a high private communication rate is that accessible information security is in general not composable. However, composable security holds against an eavesdropper who is forced to measure her share of the quantum system within a finite time after she gets it.

  7. Effectiveness of high interest rate policy on exchange rates: A reexamination of the Asian financial crisis

    Directory of Open Access Journals (Sweden)

    Chin Diew Lai

    2006-09-01

    Full Text Available One of the most controversial issues in the aftermath of the Asian financial crisis has been the appropriate response of monetary policy to a sharp decline in the value of some currencies. In this paper, we empirically examine the effects on Asian exchange rates of sharply higher interest rates during the Asian financial crisis. Taking account of the currency contagion effect, our results indicate that sharply higher interest rates helped to support the exchange rates of South Korea, the Philippines, and Thailand. For Malaysia, no significant causal relation is found from the rate of interest to exchange rates, as the authorities in Malaysia did not actively adopt a high interest rate policy to defend the currency.

  8. Lung clearance of /sup 99m/Tc-DTPA in patients with acute lung injury and pulmonary edema

    Energy Technology Data Exchange (ETDEWEB)

    Coates, G.; O' Brodovich, H.; Dolovich, M.

    1988-07-01

    Several acute and chronic conditions that alter the integrity of the pulmonary epithelium increased the rate of absorption or clearance into the circulation of small solutes deposited in the alveoli. Technetium 99m diethylenetriamine pentaacetic acid can be deposited in the lungs as a submicronic aerosol and its rate of clearance measured with a gamma camera or simple probe. This clearance technique is currently being used to evaluate patients who have developed pulmonary edema and also to detect those patients from a high risk group who are likely to develop adult respiratory distress syndrome (ARDS). Its role in the evaluation of patients with pulmonary edema is still under active investigation. It is clear that a single measurement in patients who smoke is not useful, but repeated measurements may provide important information. The lung clearance measurement is very sensitive to changes in epithelial integrity but is not specific for ARDS. It may be most useful in combination with other predictive tests or when the clearance rate is normal. 54 references.

  9. Mechanistic evaluation of virus clearance by depth filtration.

    Science.gov (United States)

    Venkiteshwaran, Adith; Fogle, Jace; Patnaik, Purbasa; Kowle, Ron; Chen, Dayue

    2015-01-01

    Virus clearance by depth filtration has not been well-understood mechanistically due to lack of quantitative data on filter charge characteristics and absence of systematic studies. It is generally believed that both electrostatic interactions and sized based mechanical entrapment contribute to virus clearance by depth filtration. In order to establish whether the effectiveness of virus clearance correlates with the charge characteristics of a given depth filter, a counter-ion displacement technique was employed to determine the ionic capacity for several depth filters. Two depth filters (Millipore B1HC and X0HC) with significant differences in ionic capacities were selected and evaluated for their ability to eliminate viruses. The high ionic capacity X0HC filter showed complete porcine parvovirus (PPV) clearance (eliminating the spiked viruses to below the limit of detection) under low conductivity conditions (≤2.5 mS/cm), achieving a log10 reduction factor (LRF) of > 4.8. On the other hand, the low ionic capacity B1HC filter achieved only ∼2.1-3.0 LRF of PPV clearance under the same conditions. These results indicate that parvovirus clearance by these two depth filters are mainly achieved via electrostatic interactions between the filters and PPV. When much larger xenotropic murine leukemia virus (XMuLV) was used as the model virus, complete retrovirus clearance was obtained under all conditions evaluated for both depth filters, suggesting the involvement of mechanisms other than just electrostatic interactions in XMuLV clearance.

  10. 高净空场所洒水喷头动作性能的数值研究%Numerical study of actuation performance of sprinkler for protection of high ceiling clearance occupancies

    Institute of Scientific and Technical Information of China (English)

    刘欣; 李毅; 田立伟; 杨丙杰

    2012-01-01

    Nmerical study was applied to analyze full scale fire tests with high ceiling clearance. Development of fire plume field was analyzed. Under the condition of specific ceiling height, sprinkler system parameter and fire development, numerical calculation was carried out to research the actuation performance of the automatic sprinkler based on sprinkler thermal response theory. The results showed that; calculation value of convective heat release rate and sprinkler actuation time is basically in agreement with experiment value, which means calculation model is reasonable and reliable. But empirical constant need to be modified concerning about different fire models.%采用数学计算的方法对高净空场所实体火灾羽流流场进行定量分析.在确定空间高度、灭火系统参数以及火灾发展过程的条件下,基于喷头热响应性能理论,通过数值计算研究高净空场所自动喷水灭火系统第一只喷头的动作性能.结果表明:流场对流热释放速率和喷头动作时间的计算值与试验值基本一致,计算模型合理可靠,但针对不同火灾模型计算模型中的经验参数仍有待进一步修正.

  11. Putative extremely high rate of proteome innovation in lancelets might be explained by high rate of gene prediction errors.

    Science.gov (United States)

    Bányai, László; Patthy, László

    2016-08-01

    A recent analysis of the genomes of Chinese and Florida lancelets has concluded that the rate of creation of novel protein domain combinations is orders of magnitude greater in lancelets than in other metazoa and it was suggested that continuous activity of transposable elements in lancelets is responsible for this increased rate of protein innovation. Since morphologically Chinese and Florida lancelets are highly conserved, this finding would contradict the observation that high rates of protein innovation are usually associated with major evolutionary innovations. Here we show that the conclusion that the rate of proteome innovation is exceptionally high in lancelets may be unjustified: the differences observed in domain architectures of orthologous proteins of different amphioxus species probably reflect high rates of gene prediction errors rather than true innovation.

  12. High Burn Rate Hybrid Fuel for Improved Grain Design Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A novel type of fuel providing high burning rate for hybrid rocket applications is proposed. This fuel maintains a hydrodynamically rough surface to...

  13. High Count Rate Single Photon Counting Detector Array Project

    Data.gov (United States)

    National Aeronautics and Space Administration — An optical communications receiver requires efficient and high-rate photon-counting capability so that the information from every photon, received at the aperture,...

  14. Quantum Communication with a High-Rate Entangled Photon Source

    Science.gov (United States)

    Wilson, Nathaniel C.; Chaffee, Dalton W.; Lekki, John D.; Wilson, Jeffrey D.

    2016-01-01

    A high generation rate photon-pair source using a dual element periodically-poled potassium titanyl phosphate (PP KTP) waveguide is described. The photon-pair source features a high pair generation rate, a compact power-efficient package, and continuous wave (CW) or pulsed operation. Characterization and test results are presented. Details and preliminary results of a laboratory free-space QKD experiment with the B92 protocol are also presented.

  15. High rate resistive plate chamber for LHC detector upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, Y., E-mail: haddad@llr.in2p3.fr [Laboratoire Leprince-Ringuet (LLR), École Polytechnique, 91120 Palaiseau (France); Laktineh, I.; Grenier, G.; Lumb, N. [IPNL, Villeurbanne 69622 Lyon (France); Cauwenbergh, S. [Ghent University, Ghent (Belgium)

    2013-08-01

    The limitation of the detection rate of standard bakelite resistive plate chambers (RPCs) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One alternative to these detectors is RPCs made with low resistivity glass plates (10{sup 10}Ωcm), a beam test at DESY has shown that such detectors can operate at few thousand Hz/cm{sup 2} with high efficiency (>90%)

  16. Urinary 6β-Hydroxycortisol/Cortisol Ratio Most Highly Correlates With Midazolam Clearance Under Hepatic CYP3A Inhibition and Induction in Females: A Pharmacometabolomics Approach.

    Science.gov (United States)

    Shin, Kwang-Hee; Ahn, Li Young; Choi, Man Ho; Moon, Ju-Yeon; Lee, Jieon; Jang, In-Jin; Yu, Kyung-Sang; Cho, Joo-Youn

    2016-09-01

    Endogenous metabolites of cytochrome P450 (CYP3A) are useful in predicting drug-drug interactions between in vivo CYP3A inhibitors and inducers for clinical applications of CYP3A substrate drugs. This study aimed to develop predictable markers of the magnitude of hepatic CYP3A induction and inhibition in healthy female subjects using pharmacometabolomics. Twelve female subjects received midazolam during three study phases: 1 mg midazolam (control phase), 1 mg midazolam after pretreatment with 400 mg ketoconazole once daily for 4 days (CYP3A inhibition phase), and 2.5 mg midazolam after pretreatment with 600 mg rifampicin once daily for 10 days (CYP3A induction phase). Throughout the study, blood samples were collected 24 h after midazolam administration and urine samples at 12-h intervals during the 24 h before and after midazolam administration for the analysis of endogenous steroid metabolites. A statistical model was generated to predict midazolam clearance using measurements of endogenous metabolites associated with the inhibition and induction of CYP3A. Mean midazolam clearance decreased to ∼20% of control levels during the inhibition phase and increased more than 2-fold during the induction phase. Of the urine and plasma metabolites measured, the 6β-hydroxycortisol/cortisol ratio was most significantly correlated with midazolam clearance during hepatic CYP3A inhibition and induction. Our results suggest that the urinary 6β-hydroxycortisol/cortisol ratio is the best predictor of hepatic CYP3A activity under both maximal inhibition and maximal induction. Furthermore, the predictive model including 6β-hydroxycortisol/cortisol as a covariate could be applied to predict the magnitude of CYP3A-mediated drug interactions.

  17. High-performance liquid chromatography of the renal blood flow marker p-aminohippuric acid (PAH) and its metabolite N-acetyl PAH improves PAH clearance measurements.

    Science.gov (United States)

    Decosterd, L A; Karagiannis, A; Roulet, J M; Bélaz, N; Appenzeller, M; Buclin, T; Vogel, P; Biollaz, J

    1997-12-05

    PAH (N-(4-aminobenzoyl)glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction but the measurements must be corrected for the unspecific residual response observed in blank plasma. We have developed a HPLC method to specifically determine PAH and its metabolite NAc-PAH using a gradient elution ion-pair reversed-phase chromatography with UV detection at 273 and 265 nm, respectively. The separations were performed at room temperature on a ChromCart (125 mmx4 mm I.D.) Nucleosil 100-5 microm C18AB cartridge column, using a gradient elution of MeOH-buffer pH 3.9 1:99-->15:85 over 15 min. The pH 3.9 buffered aqueous solution consisted in a mixture of 375 ml sodium citrate-citric acid solution (21.01 g citric acid and 8.0 g NaOH per liter), added up with 2.7 ml H3PO4 85%, 1.0 g of sodium heptanesulfonate and completed ad 1000 ml with ultrapure water. The N-acetyltransferase activity does not seem to notably affect PAH clearances, although NAc-PAH represents 10.2+/-2.7% of PAH excreted unchanged in 12 healthy subjects. The performance of the HPLC and the colorimetric method have been compared using urine and plasma samples collected from healthy volunteers. Good correlations (r=0.94 and 0.97, for plasma and urine, respectively) are found between the results obtained with both techniques. However, the colorimetric method gives higher concentrations of PAH in urine and lower concentrations in plasma than those determined by HPLC. Hence, both renal (ClR) and systemic (Cls) clearances are systematically higher (35.1 and 17.8%, respectively) with the colorimetric method. The fraction of PAH excreted by the kidney ClR/ClS calculated from HPLC data (n=143) is, as expected, always 1). In conclusion, HPLC not only enables the simultaneous quantitation of PAH and NAc-PAH, but may also provide more

  18. 30 CFR 18.24 - Electrical clearances.

    Science.gov (United States)

    2010-07-01

    ... Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor surfaces, or between uninsulated conductor surfaces and grounded metal surfaces, within the enclosure...

  19. High strain rate loading of polymeric foams and solid plastics

    Science.gov (United States)

    Dick, Richard D.; Chang, Peter C.; Fourney, William L.

    2000-04-01

    The split-Hopkinson pressure bar (SHPB) provided a technique to determine the high strain rate response for low density foams and solid ABS and polypropylene plastics. These materials are used in the interior safety panels of automobiles and crash test dummies. Because the foams have a very low impedance, polycarbonate bars were used to acquire the strain rate data in the 100 to 1600 l/s range. An aluminum SPHB setup was used to obtain the solid plastics data which covered strain rates of 1000 to 4000 l/s. The curves for peak strain rate versus peak stress for the foams over the test range studied indicates only a slight strain rate dependence. Peak strain rate versus peak stress curves for polypropylene shows a strain rate dependence up to about 1500 l/s. At that rate the solid poly propylene indicates no strain rate dependence. The ABS plastics are strain rate dependent up to 3500 l/s and then are independent at larger strain rates.

  20. HIGH HEATING RATES AFFECTS GREATLY THE INACTIVATION RATE OF ESCHERICHIA COLI

    Directory of Open Access Journals (Sweden)

    Juan Pablo Huertas

    2016-08-01

    Full Text Available Heat resistance of microorganisms can be affected by different influencing factors. Although the effect of heating rates has been scarcely explored by the scientific community, recent researches have unraveled its important effect on the thermal resistance of different species of vegetative bacteria. Typically heating rates described in the literature ranged from 1 to 20ºC/min but the impact of much higher heating rates is unclear. The aim of this research was to explore the effect of different heating rates, such as those currently achieved in the heat exchangers used in the food industry, on the heat resistance of Escherichia coli. A pilot plant tubular heat exchanger and a thermoresistometer Mastia were used for this purpose. Results showed that fast heating rates had a deep impact on the thermal resistance of E. coli. Heating rates between 20 and 50ºC/min were achieved in the heat exchanger, which were much slower than those around 20ºC/s achieved in the thermoresistometer. In all cases, these high heating rates led to higher inactivation than expected: in the heat exchanger, for all the experiments performed, when the observed inactivation had reached about seven log cycles, the predictions estimates about 1 log cycle of inactivation; in the thermoresistometer these differences between observed and predicted values were even more than ten times higher, from 4.07 log cycles observed to 0.34 predicted at a flow rate of 70 mL/min and a maximum heating rate of 14.7ºC/s. A quantification of the impact of the heating rates on the level of inactivation achieved was established. These results point out the important effect that the heating rate has on the thermal resistance of E. coli, with high heating rates resulting in an additional sensitization to heat and therefore an effective food safety strategy in terms of food processing.

  1. High Heating Rates Affect Greatly the Inactivation Rate of Escherichia coli

    Science.gov (United States)

    Huertas, Juan-Pablo; Aznar, Arantxa; Esnoz, Arturo; Fernández, Pablo S.; Iguaz, Asunción; Periago, Paula M.; Palop, Alfredo

    2016-01-01

    Heat resistance of microorganisms can be affected by different influencing factors. Although, the effect of heating rates has been scarcely explored by the scientific community, recent researches have unraveled its important effect on the thermal resistance of different species of vegetative bacteria. Typically heating rates described in the literature ranged from 1 to 20°C/min but the impact of much higher heating rates is unclear. The aim of this research was to explore the effect of different heating rates, such as those currently achieved in the heat exchangers used in the food industry, on the heat resistance of Escherichia coli. A pilot plant tubular heat exchanger and a thermoresistometer Mastia were used for this purpose. Results showed that fast heating rates had a deep impact on the thermal resistance of E. coli. Heating rates between 20 and 50°C/min were achieved in the heat exchanger, which were much slower than those around 20°C/s achieved in the thermoresistometer. In all cases, these high heating rates led to higher inactivation than expected: in the heat exchanger, for all the experiments performed, when the observed inactivation had reached about seven log cycles, the predictions estimated about 1 log cycle of inactivation; in the thermoresistometer these differences between observed and predicted values were even more than 10 times higher, from 4.07 log cycles observed to 0.34 predicted at a flow rate of 70 mL/min and a maximum heating rate of 14.7°C/s. A quantification of the impact of the heating rates on the level of inactivation achieved was established. These results point out the important effect that the heating rate has on the thermal resistance of E. coli, with high heating rates resulting in an additional sensitization to heat and therefore an effective food safety strategy in terms of food processing. PMID:27563300

  2. Radio Interface for High Data Rate Wireless Sensor Networks

    CERN Document Server

    Henaut, Julien; Dragomirescu, Daniela; Plana, Robert

    2010-01-01

    This paper gives an overview of radio interfaces devoted for high data rate Wireless Sensor Networks. Four aerospace applications of WSN are presented to underline the importance of achieving high data rate. Then, two modulation schemes by which High Data Rate can be achieved are compared : Multi carrier approaches, represented by the popular Orthogonal Frequency Division Multiplexing (OFDM) and Single carrier methods, represented by Single Carrier Frequency division Equalization and its application for multiple access Single Carrier Frequency division multiple Access (SC-FDMA). SC-FDMA, with a very low Peak Average Power Ratio (PAPR), is as strong alternative to the OFDM scheme for highly power constraint application. The Chosen radio interface will be, finally, tested by a model based design approach based on Simulink and FPGA realization. SC-FDMA, with a very low Peak Average Power Ratio (PAPR), is as strong alternative to the OFDM scheme for highly power constraint application. The Chosen radio interface ...

  3. A prototype wireless inertial-sensing device for measuring toe clearance.

    Science.gov (United States)

    Lai, Daniel T H; Charry, E; Begg, R; Palaniswami, M

    2008-01-01

    Tripping and slipping are serious health concerns for the elderly because they result in life threatening injuries i.e., fractures and high medical costs. Our recent work in detection of tripping gait patterns has demonstrated that minimum toe clearance (MTC) is a sensitive falls risk predictor. MTC measurement has previously been done in gait laboratories and on treadmills which potentially imposes controlled walking conditions. In this paper, we describe a prototype design of a wireless device for monitoring vertical toe clearance. The sensors consists of a tri-axis accelerometer and dual-axis gyroscope connected to Crossbow sensor motes for wireless data transmission. Sensor data are transmitted to a laptop and displayed on a Matlab graphic user interface (GUI). We have performed zero base and treadmill experiments to investigate sensor performance to environmental variations and compared the calculated toe clearance against measurements made by an Optotrak motion system. It was found that device outputs were approximately independent of small ambient temperature variations, had a reliable range of 20m indoors and 50m outdoors and a maximum transmission rate of 20 packets/s. Toe clearance measurements were found to follow the Optotrak measurement trend but could be improved further by dealing with double integration errors and improving data transmission rates.

  4. Stretching Behavior of Red Blood Cells at High Strain Rates

    Science.gov (United States)

    Mancuso, Jordan; Ristenpart, William

    2016-11-01

    Most work on the mechanical behavior of red blood cells (RBCs) has focused on simple shear flows. Relatively little work has examined RBC deformations in the physiologically important extensional flow that occurs at the entrance to a constriction. In particular, previous work suggests that RBCs rapidly stretch out and then retract upon entering the constriction, but to date no model predicts this behavior for the extremely high strain rates typically experienced there. In this work, we use high speed video to perform systematic measurements of the dynamic stretching behavior of RBCs as they enter a microfluidic constriction. We demonstrate that a simple viscoelastic model captures the observed stretching dynamics, up to strain rates as high as 1000 s-1. The results indicate that the effective elastic modulus of the RBC membrane at these strain rates is an order of magnitude larger than moduli measured by micropipette aspiration or other low strain rate techniques.

  5. Solidification at the High and Low Rate Extreme

    Energy Technology Data Exchange (ETDEWEB)

    Meco, Halim [Iowa State Univ., Ames, IA (United States)

    2004-12-19

    The microstructures formed upon solidification are strongly influenced by the imposed growth rates on an alloy system. Depending on the characteristics of the solidification process, a wide range of growth rates is accessible. The prevailing solidification mechanisms, and thus the final microstructure of the alloy, are governed by these imposed growth rates. At the high rate extreme, for instance, one can have access to novel microstructures that are unattainable at low growth rates. While the low growth rates can be utilized for the study of the intrinsic growth behavior of a certain phase growing from the melt. Although the length scales associated with certain processes, such as capillarity, and the diffusion of heat and solute, are different at low and high rate extremes, the phenomena that govern the selection of a certain microstructural length scale or a growth mode are the same. Consequently, one can analyze the solidification phenomena at both high and low rates by using the same governing principles. In this study, we examined the microstructural control at both low and high extremes. For the high rate extreme, the formation of crystalline products and factors that control the microstructure during rapid solidification by free-jet melt spinning are examined in Fe-Si-B system. Particular attention was given to the behavior of the melt pool at different quench-wheel speeds. Since the solidification process takes place within the melt-pool that forms on the rotating quench-wheel, we examined the influence of melt-pool dynamics on nucleation and growth of crystalline solidification products and glass formation. High-speed imaging of the melt-pool, analysis of ribbon microstructure, and measurement of ribbon geometry and surface character all indicate upper and lower limits for melt-spinning rates for which nucleation can be avoided, and fully amorphous ribbons can be achieved. Comparison of the relevant time scales reveals that surface-controlled melt

  6. High deposition rate nanocrystalline silicon with enhanced homogeneity

    NARCIS (Netherlands)

    Verkerk, A.; Rath, J.K.; Schropp, R.E.I.

    2010-01-01

    High rate growth of hydrogenated nanocrystalline silicon (nc-Si:H) brings additional challenges for the homogeneity in the growth direction, since the start-up effects affect a larger portion of the film, and the very high degree of depletion increases the influence of back diffusion from the inacti

  7. 男大学生中长跑运动员训练过程生理生化指标研究——心率恢复率、血乳酸清除率变化情况%A Study of the Physiological Index of Male College Middle- Distance Race Athletes in Different Training Stages Changes in Heart Rate Recovery Rate, and Blood Lactate Clearance Rate

    Institute of Scientific and Technical Information of China (English)

    王瑞锋; 林争平; 李纳新; 涂秀全; 陈华; 陈瑞云; 沈秀云; 陈晨; 陈传新

    2012-01-01

    Through the methods of laboratory research, literature consultation, mathematical statistics, comprehensive analysis, etc. , this article studies the blood lactate clearance rate and heart rate recovery rate in different training stages. By measuring the blood lactate clearance rate and heart rate recovery rate, we find that athletes arrangement of intensity and intermittent time arrangements are not the same: in the initial stage, athletes exercise intensity is smaller; intermittent time is about 9min; training after three months, training intensity can be appropriately increased; intermittent time adjustment is about 8min, when the system continues to six months after training, the athletes blood lactate clearance rate and heart rate recovery rate have reached a higher level, so it can be used with larger intensity of training, appropriately to reduce the training time and the interval time can be adjusted to about 7min.%通过实验室研究方法、文献资料法、数理统计法、综合分析法等研究方法对业余男中长跑运动员在不同训练阶段的血乳酸清除率、心率恢复率等指标进行测定,得出了不同训练阶段运动员的运动强度安排、间歇时间安排应不同的结论.运动员在训练初期运动强度要小些,间歇时间为9min左右;训练三个月后训练强度可适当加大,间歇时间调整为8min左右;当系统训练半年后由于运动员的血乳酸清除率和心率恢复率都达到了一个较高的水平,可以采用较大的训练强度,适当地缩短训练时间,将间歇时间调整为7min左右.

  8. High-rate squeezing process of bulk metallic glasses

    Science.gov (United States)

    Fan, Jitang

    2017-03-01

    High-rate squeezing process of bulk metallic glasses from a cylinder into an intact sheet achieved by impact loading is investigated. Such a large deformation is caused by plastic flow, accompanied with geometrical confinement, shear banding/slipping, thermo softening, melting and joining. Temperature rise during the high-rate squeezing process makes a main effect. The inherent mechanisms are illustrated. Like high-pressure torsion (HPT), equal channel angular pressing (ECAP) and surface mechanical attrition treatments (SMAT) for refining grain of metals, High-Rate Squeezing (HRS), as a multiple-functions technique, not only creates a new road of processing metallic glasses and other metallic alloys for developing advanced materials, but also directs a novel technology of processing, grain refining, coating, welding and so on for treating materials.

  9. High power, high efficiency millimeter wavelength traveling wave tubes for high rate communications from deep space

    Science.gov (United States)

    Dayton, James A., Jr.

    1991-01-01

    The high-power transmitters needed for high data rate communications from deep space will require a new class of compact, high efficiency traveling wave tubes (TWT's). Many of the recent TWT developments in the microwave frequency range are generically applicable to mm wave devices, in particular much of the technology of computer aided design, cathodes, and multistage depressed collectors. However, because TWT dimensions scale approximately with wavelength, mm wave devices will be physically much smaller with inherently more stringent fabrication tolerances and sensitivity to thermal dissipation.

  10. Evolution of high tooth replacement rates in sauropod dinosaurs.

    Directory of Open Access Journals (Sweden)

    Michael D D'Emic

    Full Text Available BACKGROUND: Tooth replacement rate can be calculated in extinct animals by counting incremental lines of deposition in tooth dentin. Calculating this rate in several taxa allows for the study of the evolution of tooth replacement rate. Sauropod dinosaurs, the largest terrestrial animals that ever evolved, exhibited a diversity of tooth sizes and shapes, but little is known about their tooth replacement rates. METHODOLOGY/PRINCIPAL FINDINGS: We present tooth replacement rate, formation time, crown volume, total dentition volume, and enamel thickness for two coexisting but distantly related and morphologically disparate sauropod dinosaurs Camarasaurus and Diplodocus. Individual tooth formation time was determined by counting daily incremental lines in dentin. Tooth replacement rate is calculated as the difference between the number of days recorded in successive replacement teeth. Each tooth family in Camarasaurus has a maximum of three replacement teeth, whereas each Diplodocus tooth family has up to five. Tooth formation times are about 1.7 times longer in Camarasaurus than in Diplodocus (315 vs. 185 days. Average tooth replacement rate in Camarasaurus is about one tooth every 62 days versus about one tooth every 35 days in Diplodocus. Despite slower tooth replacement rates in Camarasaurus, the volumetric rate of Camarasaurus tooth replacement is 10 times faster than in Diplodocus because of its substantially greater tooth volumes. A novel method to estimate replacement rate was developed and applied to several other sauropodomorphs that we were not able to thin section. CONCLUSIONS/SIGNIFICANCE: Differences in tooth replacement rate among sauropodomorphs likely reflect disparate feeding strategies and/or food choices, which would have facilitated the coexistence of these gigantic herbivores in one ecosystem. Early neosauropods are characterized by high tooth replacement rates (despite their large tooth size, and derived titanosaurs and

  11. High Frame Rate Synthetic Aperture 3D Vector Flow Imaging

    DEFF Research Database (Denmark)

    Villagómez Hoyos, Carlos Armando; Holbek, Simon; Stuart, Matthias Bo

    2016-01-01

    3-D blood flow quantification with high spatial and temporal resolution would strongly benefit clinical research on cardiovascular pathologies. Ultrasonic velocity techniques are known for their ability to measure blood flow with high precision at high spatial and temporal resolution. However......, current volumetric ultrasonic flow methods are limited to one velocity component or restricted to a reduced field of view (FOV), e.g. fixed imaging planes, in exchange for higher temporal resolutions. To solve these problems, a previously proposed accurate 2-D high frame rate vector flow imaging (VFI......) technique is extended to estimate the 3-D velocity components inside a volume at high temporal resolutions (

  12. High Strain Rate Behavior of Polymer Matrix Composites Analyzed

    Science.gov (United States)

    Goldberg, Robert K.; Roberts, Gary D.

    2001-01-01

    Procedures for modeling the high-speed impact of composite materials are needed for designing reliable composite engine cases that are lighter than the metal cases in current use. The types of polymer matrix composites that are likely to be used in such an application have a deformation response that is nonlinear and that varies with strain rate. To characterize and validate material models that could be used in the design of impactresistant engine cases, researchers must obtain material data over a wide variety of strain rates. An experimental program has been carried out through a university grant with the Ohio State University to obtain deformation data for a representative polymer matrix composite for strain rates ranging from quasi-static to high rates of several hundred per second. This information has been used to characterize and validate a constitutive model that was developed at the NASA Glenn Research Center.

  13. Study of High Strain Rate Response of Composites

    Science.gov (United States)

    Gilat, Amos

    2003-01-01

    The objective of the research was to continue the experimental study of the effect of strain rate on mechanical response (deformation and failure) of epoxy resins and carbon fibers/epoxy matrix composites, and to initiate a study of the effects of temperature by developing an elevated temperature test. The experimental data provide the information needed for NASA scientists for the development of a nonlinear, rate dependent deformation and strength models for composites that can subsequently be used in design. This year effort was directed into testing the epoxy resin. Three types of epoxy resins were tested in tension and shear at various strain rates that ranges from 5 x 10(exp -5), to 1000 per second. Pilot shear experiments were done at high strain rate and an elevated temperature of 80 C. The results show that all, the strain rate, the mode of loading, and temperature significantly affect the response of epoxy.

  14. STIR: Tailored Interfaces for High Strength Composites Across Strain Rates

    Science.gov (United States)

    2013-09-02

    was requested during our kickoff meeting at ARL APG. High performance fabrics including Kevlar, Twaron, Zylon , and Dyneema are used in developing...Kevlar, and Zylon for various pullout rates. Force– displacement data was recorded, and both warp and fill yarns were pulled from the fabric. Their...results presented that the effect of pullout rate is negligible for Kevlar, whereas the effect is bigger on Spectra, and significant for Zylon

  15. High rate tests of the LHCb RICH Upgrade system

    CERN Multimedia

    Blago, Michele Piero

    2016-01-01

    One of the biggest challenges for the upgrade of the LHCb RICH detectors from 2020 is to readout the photon detectors at the full 40 MHz rate of the LHC proton-proton collisions. A test facility has been setup at CERN with the purpose to investigate the behaviour of the Multi Anode PMTs, which have been proposed for the upgrade, and their readout electronics at high trigger rates. The MaPMTs are illuminated with a monochromatic laser that can be triggered independently of the readout electronics. A first series of tests, including threshold scans, is performed at low trigger rates (20 kHz) for both the readout and the laser with the purpose to characterise the behaviour of the system under test. Then the trigger rate is increased in two separate steps. First the MaPMTs are exposed to high illumination by triggering the pulsed laser at a high (20 MHz) repetition rate while the DAQ is readout at the same low rate as before. In this way the performance of the MaPMTs and the attached electronics can be evaluated ...

  16. Nanoengineering Titania for High Rate Lithium Storage: A Review

    Institute of Scientific and Technical Information of China (English)

    Chunhai Jiang; Jinsong Zhang

    2013-01-01

    Nanostructured titania have been intensively investigated as anode materials of Li-ion batteries for their excellent high rate performance.The size effects of TiO2 polymorphs (mainly rutile,anatase and TiO2-B) on their electrochemical performance and the latest efforts in nanoengineering titania anodes through enhancing their ionic or electronic transportation or both are reviewed in this work.We suppose that micron-or submicronsized porous structures assembled by TiO2 nanoparticles,nanowires/nanotubes or nanosheets with a high percentage of exposing high reactive facets together with a conductive percolating network are ideal anodes not only for high rate lithium storage but also for high packing densities of the active materials.

  17. Semi-solid electrodes having high rate capability

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Yet-Ming; Duduta, Mihai; Holman, Richard; Limthongkul, Pimpa; Tan, Taison

    2016-07-05

    Embodiments described herein relate generally to electrochemical cells having high rate capability, and more particularly to devices, systems and methods of producing high capacity and high rate capability batteries having relatively thick semi-solid electrodes. In some embodiments, an electrochemical cell includes an anode, a semi-solid cathode that includes a suspension of an active material and a conductive material in a liquid electrolyte, and an ion permeable membrane disposed between the anode and the cathode. The semi-solid cathode has a thickness in the range of about 250 .mu.m-2,500 .mu.m, and the electrochemical cell has an area specific capacity of at least 5 mAh/cm.sup.2 at a C-rate of C/2.

  18. Semi-solid electrodes having high rate capability

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Yet-Ming; Duduta, Mihai; Holman, Richard; Limthongkul, Pimpa; Tan, Taison

    2015-11-10

    Embodiments described herein relate generally to electrochemical cells having high rate capability, and more particularly to devices, systems and methods of producing high capacity and high rate capability batteries having relatively thick semi-solid electrodes. In some embodiments, an electrochemical cell includes an anode, a semi-solid cathode that includes a suspension of an active material and a conductive material in a liquid electrolyte, and an ion permeable membrane disposed between the anode and the cathode. The semi-solid cathode has a thickness in the range of about 250 .mu.m-2,500 .mu.m, and the electrochemical cell has an area specific capacity of at least 5 mAh/cm.sup.2 at a C-rate of C/2.

  19. High strain rate compression testing of glass fibre reinforced polypropylene

    Directory of Open Access Journals (Sweden)

    Cloete T.J.

    2012-08-01

    Full Text Available This paper details an investigation of the high strain rate compression testing of GFPP with the Split Hopkinson Pressure Bar (SHPB in the through-thickness and in-plane directions. GFPP posed challenges to SHPB testing as it fails at relatively high stresses, while having relatively low moduli and hence mechanical impedance. The modifications to specimen geometry and incident pulse shaping in order to gather valid test results, where specimen equilibrium was achieved for SHPB tests on GFPP are presented. In addition to conventional SHPB tests to failure, SHPB experiments were designed to achieve specimen equilibration at small strains, which permitted the capture of high strain rate elastic modulus data. The strain rate dependency of GFPP’s failure strengths in the in-plane and through-thickness direction is modelled using a logarithmic law.

  20. High-Strain Rate Mechanical Response of Cured Epoxy Networks

    Science.gov (United States)

    Sirk, Timothy; Khare, Ketan; Karim, Mir; Lenhart, Joseph; Khare, Rajesh; Andzelm, Jan

    2013-03-01

    Chemically cross-linked polymer networks are increasingly common in high performance composites, adhesives and other applications involving high-impact loading conditions or ballistic collisions. The mechanical behavior of epoxy and other polymer networks exhibit a strong dependence on strain rate near the glass transition temperature (Tg); however, the elastic modulus at strain rates greater than 105 1/s is difficult to capture with experimental techniques. We present computational results of Di-Glycidyl Ether of Bisphenol A (DGEBA) and Jeffamine diamines (D230) from molecular dynamics simulation, which is intrinsically well-suited to model material deformation at high strain rates. Our results show that the experimental Tg can be reproduced from molecular dynamics, and the Williams-Landel-Ferry equation is useful in rationalizing the shift of Tg due to fast annealing and high strain rates. Temperature sweeps of elastic modulus show the glass-rubber transition to occur over a significantly wider temperature range compared with experimental measurements at low strain rates.

  1. Clearance of protoporphyrin IX induced by 5-aminolevulinic acid from WiDr human colon carcinoma cells

    Science.gov (United States)

    Juzeniene, Asta; Kaliszewski, Miron; Bugaj, Andrzej; Moan, Johan

    2009-06-01

    5-aminolevulinic acid-mediated photodynamic therapy (ALA-PDT) is the most widely practiced form of PDT in dermatology. One of the advantages of ALA-PDT is that undesirable photosensitization lasts only for 24-48 h. In order to optimize ALA-PDT it is necessary to understand the mechanisms controlling intracellular PpIX clearance (efflux and transformation into heme) in order to decrease protoporphyrin IX (PpIX) clearance rates in the early stages of its production. The aim of this study was to investigate the factors controlling the clearance of intracellular PpIX. Fluorescence spectroscopy was used to study PpIX kinetics in WiDr cells initially treated with ALA. The clearance rate of PpIX in WiDr cells was faster after application of a low concentration of ALA (0.1 mM) than after application of high concentration of ALA (1 mM). PpIX was cleared faster from cells which initially were seeded at low densities than cells seeded at higher densities. The presence of the iron chelator deferoxamine reduced the clearance rate of PpIX, while the presence of ferrous sulfate acted oppositely. The decay rate of PpIX in WiDr cells was faster at higher temperature than at lower. The ferrochelatase activity at pH 7.2 was significantly greater than that at pH 6.7. ALA concentration, application time, cell density, temperature, pH, intracellular iron content, intracellular amount and localization of PpIX are factors controlling PpIX clearance.

  2. Visualization of Tear Clearance Using Anterior Segment Optical Coherence Tomography and Polymethylmethacrylate Particles.

    Science.gov (United States)

    Zheng, Xiaodong; Yamaguchi, Masahiko; Kamao, Tomoyuki; Sakane, Yuri; Goto, Tomoko; Shiraishi, Atsushi; Ohashi, Yuichi

    2016-11-01

    We previously reported 2 new methods, anterior segment optical coherence tomography (AS-OCT) and polymethylmethacrylate particles suspended in fluorescein solution (PPF), for the evaluation of tear clearance and rapid tear flow after blinking (tear Krehbiel flow). Here, we investigated age-related OCT tear clearance and tear film thickness (TFT) and the potential correlation of OCT tear clearance and PPF velocity indicative of tear Krehbiel flow. Normal subjects separated into young and older groups received 5 μL of saline solution into the lower conjunctival sac, and an image of the central lower eyelid tear meniscus was captured by AS-OCT immediately and 30 seconds after natural blinking. Tear meniscus height (TMH) and tear meniscus area (TMA) were measured, and their percentage decrease was defined as OCT clearance rate. A Spectralis OCT Anterior Segment Module captured the central corneal tear film layer for TFT measurements. OCT clearance rates were significantly higher in young versus older subjects (P = 0.0002). When all subjects were analyzed, age was significantly and negatively correlated with TMH clearance rate (r = -0.4928, P = 0.0003) and TMA clearance rate (r = -0.4596, P = 0.0008). TFT values were significantly and negatively correlated with age (r = -0.6662, P clearance rates and PPF velocity (TMH rate: r = 0.2926, P = 0.0392; TMA rate: r = 0.3274, P = 0.0205). AS-OCT and PPF might be novel techniques for quantitative evaluation of tear clearance and Krehbiel flow.

  3. High removal rate laser-based coating removal system

    Science.gov (United States)

    Matthews, Dennis L.; Celliers, Peter M.; Hackel, Lloyd; Da Silva, Luiz B.; Dane, C. Brent; Mrowka, Stanley

    1999-11-16

    A compact laser system that removes surface coatings (such as paint, dirt, etc.) at a removal rate as high as 1000 ft.sup.2 /hr or more without damaging the surface. A high repetition rate laser with multiple amplification passes propagating through at least one optical amplifier is used, along with a delivery system consisting of a telescoping and articulating tube which also contains an evacuation system for simultaneously sweeping up the debris produced in the process. The amplified beam can be converted to an output beam by passively switching the polarization of at least one amplified beam. The system also has a personal safety system which protects against accidental exposures.

  4. Strategies for adapting to high rates of employee turnover.

    Science.gov (United States)

    Mowday, R T

    1984-01-01

    For many organizations facing high rates of employee turnover, strategies for increasing employee retention may not be practical because employees leave for reasons beyond the control of management or the costs of reducing turnover exceed the benefits to be derived. In this situation managers need to consider strategies that can minimize or buffer the organization from the negative consequences that often follow from turnover. Strategies organizations can use to adapt to uncontrollably high employee turnover rates are presented in this article. In addition, suggestions are made for how managers should make choices among the alternative strategies.

  5. 33 CFR 117.47 - Clearance gauges.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Clearance gauges. 117.47 Section... OPERATION REGULATIONS General Requirements § 117.47 Clearance gauges. (a) Clearance gauges are required for... specify otherwise for particular drawbridges, clearance gauges shall be designed, installed,...

  6. 30 CFR 57.11010 - Stairstep clearance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Stairstep clearance. 57.11010 Section 57.11010... Escapeways Travelways-Surface and Underground § 57.11010 Stairstep clearance. Vertical clearance above stair... to indicate an impaired clearance....

  7. 30 CFR 56.11008 - Restricted clearance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Restricted clearance. 56.11008 Section 56.11008 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Restricted clearance. Where restricted clearance creates a hazard to persons, the restricted clearance...

  8. 30 CFR 56.11010 - Stairstep clearance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Stairstep clearance. 56.11010 Section 56.11010... Stairstep clearance. Vertical clearance above stair steps shall be a minimum of seven feet, or suitable warning signs or similar devices shall be provided to indicate an impaired clearance....

  9. 30 CFR 57.11008 - Restricted clearance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Restricted clearance. 57.11008 Section 57.11008... Escapeways Travelways-Surface and Underground § 57.11008 Restricted clearance. Where restricted clearance creates a hazard to persons, the restricted clearance shall be conspicuously marked....

  10. 14 CFR 25.925 - Propeller clearance.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most...

  11. 32 CFR 154.16 - Security clearance.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Security clearance. 154.16 Section 154.16... clearance. (a) General. (1) The authorities designated in paragraph A, Appendix E are the only authorities authorized to grant, deny or revoke DoD personnel security clearances. The granting of such clearances...

  12. 28 CFR 524.74 - Activities clearance.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Activities clearance. 524.74 Section 524... clearance. (a) Except as provided for in paragraph (b) of this section, the Warden is the clearance... Security cases. Central Office Inmate Monitoring Section staff shall be the clearance authority on...

  13. Evaluation of {sup 123}I-orthoiodohippurate single kidney clearance rate by renal sequential scintigraphy in a large cohort of likely normal subjects aged between 0 and 18 years

    Energy Technology Data Exchange (ETDEWEB)

    Imperiale, Alessio; Olianti, Catia; Comis, Giannetto; Cava, Giuseppe la [University of Florence, Nuclear Medicine Unit, Department of Clinical Pathophysiology, Florence (Italy)

    2006-12-15

    Age-related values of{sup 123}I-orthoiodohippurate (OIH) single kidney clearance rate (Cl) were estimated in a large cohort of likely normal children aged between 0 and 18 years. Among 4,111 children examined in the past 10 years, 917 were selected with the following inclusion criteria: (a) mild ultrasonographic hydronephrosis with right differential renal function (DRF) <53% and >47% (498 pts), (b) known or suspected urinary tract infection with normal ultrasound, serum creatinine and DMSA and DRF <53% and >47% (419 pts).{sup 123}I-OIH-Cl was assessed using a validated gamma camera method. Children were divided into 21 age classes: from 0 to 2 years, eight 3-month classes; from 2 to 14 years, twelve 1-year classes; from 14 to 18 years, one 4-year class. Cl, plotted against age, was fitted using an increasing function (y = a - be - cx). Mean{sup 123}I-OIH-Cl of 1,834 kidneys was 306{+-}22 ml/min/1.73 m{sup 2} BSA. Mean{sup 123}I-OIH-Cl of the right and left kidneys was 307{+-}23 and 305{+-}22 ml/min/1.73 m{sup 2} BSA, respectively (p<0.002). The best-fitting{sup 123}I-OIH-Cl growing function was: Cl=311-230e-0.69 x Age (months).{sup 123}I-OIH-Cl improved progressively starting from birth, reaching 96% and 98% of the mature value at 1 and 1.5 years, respectively.{sup 123}I-OIH-Cl at birth (age=0) was 81 ml/min/1.73 m{sup 2} BSA. After 18.6 days of life, the renal function had doubled its starting value, and it reached a plateau of 311 ml/min/1.73 m{sup 2} BSA at 2 years. This work represents a systematic evaluation of ERPF by a gamma camera method in a large cohort of selected likely normal paediatric subjects. (orig.)

  14. 前掠对高负荷风扇转子泄漏涡结构的影响%Numerically Investigating Effects of Highly-loaded and Forward-swept Fan Rotor on Tip Clearance Vortex

    Institute of Scientific and Technical Information of China (English)

    王雷; 刘波; 赵鹏程

    2012-01-01

    We numerically calculate the three-dimensional viscous flow field near the blade tip region at the near stall margin of a highly-loaded and forward-swept fan rotor. We compare the effects of the forward-swept fan rotor on the tip clearance vortex structure with those of a conventionally stacked radial rotor that has aerodynamically equal performance. The comparison results show that both the stall margin of the forward-swept fan rotor and the distribu- tion of its aerodynamic tip loading are improved. Our detailed analysis of its flow field reveals that the tip clearance vortex of the forward-swept fan rotor does not break under the near stall condition, thus providing a novel explanation why the tip clearance vortex structure of a forward-swept fan rotor is different from that of a conventional fan rotor.%以高负荷两级风扇第一级前掠转子为研究对象,通过数值模拟手段对近失速点叶尖流场进行了深入分析。为比较前掠对泄漏涡结构的影响,与同等气动性能下的常规转子进行了对比。结果表明前掠转子在近失速工况下泄漏涡涡心并未发生破碎,气动负荷展向分布更加均匀。对前掠转子不同于常规转子的叶尖泄漏涡结构产生机理提出了新的解释。

  15. Integrated Turbine Tip Clearance and Gas Turbine Engine Simulation

    Science.gov (United States)

    Chapman, Jeffryes W.; Kratz, Jonathan; Guo, Ten-Huei; Litt, Jonathan

    2016-01-01

    Gas turbine compressor and turbine blade tip clearance (i.e., the radial distance between the blade tip of an axial compressor or turbine and the containment structure) is a major contributing factor to gas path sealing, and can significantly affect engine efficiency and operational temperature. This paper details the creation of a generic but realistic high pressure turbine tip clearance model that may be used to facilitate active tip clearance control system research. This model uses a first principles approach to approximate thermal and mechanical deformations of the turbine system, taking into account the rotor, shroud, and blade tip components. Validation of the tip clearance model shows that the results are realistic and reflect values found in literature. In addition, this model has been integrated with a gas turbine engine simulation, creating a platform to explore engine performance as tip clearance is adjusted. Results from the integrated model explore the effects of tip clearance on engine operation and highlight advantages of tip clearance management.

  16. Increased hepatic insulin clearance after Roux-en-Y gastric bypass

    DEFF Research Database (Denmark)

    Bojsen-Møller, Kirstine N; Dirksen, Carsten; Jørgensen, Nils B;

    2013-01-01

    Context:Roux-en-Y gastric bypass (RYGB) improves glucose tolerance and ameliorates fasting hyperinsulinemia within days after surgery. Improvements in hepatic insulin sensitivity and insulin clearance could contribute importantly to these effects.Objective:The objective of the investigation...... was to study changes in insulin clearance after RYGB.Design:This was a prospective study of fasting hepatic insulin clearance and, in a subgroup of patients, postprandial insulin clearance after a meal test before and 1 week, 3 months, and 1 year after RYGB.Setting:The study was conducted at Hvidovre Hospital......:Fasting hepatic insulin clearance (fasting C-peptide/fasting insulin). Postprandial insulin clearance (incremental areas under the curve of insulin secretion rates/incremental areas under the curve of insulin).Results:Fasting hepatic insulin clearance increased after 1 week (P

  17. Experimental study on fluid flow in arciform clearance

    Institute of Scientific and Technical Information of China (English)

    邵俊鹏; 汤卉; 贾慧娟

    2002-01-01

    The system damping and dynamic characteristics can be further improved by properly increasing thedamping coefficient ξh. For a special hydraulic damping structure, an arciform damping clearance often used inFCS, a mathematical model has been established for fluid flow using the theory of laminar flow in the clearanceof parallel plates. Analytical calculations are made for fluid flow in the arciform clearance and relational expres-sion is deduced for flow rate along the arciform cleaance height, pressure difference, maximum arciform clear-ance height, the flow rate for the fluid flow in arciform clearance as well, and its simplified formula is obtainedby using the theory of hydrodynamics and the curve - fitting method. This paper consists of two sections: the firstsection focuses on the theoretical analysis by using the simplified mathematical model and the second sectionmainly describes experimental analysis. The simplified formula is corrected with experimental results by consid-erig various boundary conditions of the damping clearance. Experimental results show that this study of arciformdamping clearance is reliable and practical.

  18. High frame rate CCD camera with fast optical shutter

    Energy Technology Data Exchange (ETDEWEB)

    Yates, G.J.; McDonald, T.E. Jr. [Los Alamos National Lab., NM (United States); Turko, B.T. [Lawrence Berkeley National Lab., CA (United States)

    1998-09-01

    A high frame rate CCD camera coupled with a fast optical shutter has been designed for high repetition rate imaging applications. The design uses state-of-the-art microchannel plate image intensifier (MCPII) technology fostered/developed by Los Alamos National Laboratory to support nuclear, military, and medical research requiring high-speed imagery. Key design features include asynchronous resetting of the camera to acquire random transient images, patented real-time analog signal processing with 10-bit digitization at 40--75 MHz pixel rates, synchronized shutter exposures as short as 200pS, sustained continuous readout of 512 x 512 pixels per frame at 1--5Hz rates via parallel multiport (16-port CCD) data transfer. Salient characterization/performance test data for the prototype camera are presented, temporally and spatially resolved images obtained from range-gated LADAR field testing are included, an alternative system configuration using several cameras sequenced to deliver discrete numbers of consecutive frames at effective burst rates up to 5GHz (accomplished by time-phasing of consecutive MCPII shutter gates without overlap) is discussed. Potential applications including dynamic radiography and optical correlation will be presented.

  19. User microprogrammable processors for high data rate telemetry preprocessing

    Science.gov (United States)

    Pugsley, J. H.; Ogrady, E. P.

    1973-01-01

    The use of microprogrammable processors for the preprocessing of high data rate satellite telemetry is investigated. The following topics are discussed along with supporting studies: (1) evaluation of commercial microprogrammable minicomputers for telemetry preprocessing tasks; (2) microinstruction sets for telemetry preprocessing; and (3) the use of multiple minicomputers to achieve high data processing. The simulation of small microprogrammed processors is discussed along with examples of microprogrammed processors.

  20. Effect of increased surface tension and assisted ventilation on /sup 99m/Tc-DTPA clearance

    Energy Technology Data Exchange (ETDEWEB)

    Jefferies, A.L.; Kawano, T.; Mori, S.; Burger, R.

    1988-02-01

    Experiments were performed to determine the effects of conventional mechanical ventilation (CMV) and high-frequency oscillation (HFO) on the clearance of technetium-99m-labeled diethylenetriamine pentaacetate (/sup 99m/Tc-DTPA) from lungs with altered surface tension properties. A submicronic aerosol of /sup 99m/Tc-DTPA was insufflated into the lungs of anesthetized, tracheotomized rabbits before and 1 h after the administration of the aerosolized detergent dioctyl sodium sulfosuccinate (OT). Rabbits were ventilated by one of four methods: 1) spontaneous breathing; 2) CMV at 12 cmH2O mean airway pressure (MAP); 3) HFO at 12 cmH2O MAP; 4) HFO at 16 cmH2O MAP. Administration of OT resulted in decreased arterial PO2 (PaO2), increased lung wet-to-dry weight ratios, and abnormal lung pressure-volume relationships, compatible with increased surface tension. /sup 99m/Tc-DTPA clearance was accelerated after OT in all groups. The post-OT rate of clearance (k) was significantly faster (P less than 0.05) in the CMV at 12 cmH2O MAP (k = 7.57 +/- 0.71%/min (SE)) and HFO at 16 cmH2O MAP (k = 6.92 +/- 0.61%/min) groups than in the spontaneously breathing (k = 4.32 +/- 0.55%/min) and HFO at 12 cmH2O MAP (4.68 +/- 0.63%/min) groups. The clearance curves were biexponential in the former two groups. We conclude that pulmonary clearance of /sup 99m/Tc-DTPA is accelerated in high surface tension pulmonary edema, and this effect is enhanced by both conventional ventilation and HFO at high mean airway pressure.

  1. Pedalling rate affects endurance performance during high-intensity cycling

    DEFF Research Database (Denmark)

    Nielsen, Jens Steen; Hansen, Ernst Albin; Sjøgaard, Gisela

    2004-01-01

    , such as muscle fibre type composition and power reserve, relate to endurance time. Twenty males underwent testing to determine their maximal oxygen uptake (VO(2max)), power output corresponding to 90% of VO(2max) at 80 rpm (W90), FCPR at W90, percentage of slow twitch muscle fibres (% MHC I), maximal leg power...... time was negatively related to VO(2max), W90 and % MHC I, while positively related to power reserve. In conclusion, at group level, endurance time was longer at FCPR and at a pedalling rate 25% lower compared to a pedalling rate 25% higher than FCPR. Further, inter-individual physiological variables......The purpose of this study into high-intensity cycling was to: (1) test the hypothesis that endurance time is longest at a freely chosen pedalling rate (FCPR), compared to pedalling rates 25% lower (FCPR-25) and higher (FCPR+25) than FCPR, and (2) investigate how physiological variables...

  2. Evaluation of dissolution rate on high plutonium content MOX fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sugaya, Shinichi; Kurita, Ichiro; Endo, Hideo; Higuchi, Hidetoshi; Kihara, Yoshiyuki [Japan Nuclear Cycle Development Inst., Tokai Works, Tokai, Ibaraki (Japan); Ogasawara, Masahiro; Shinada, Masanori; Kowata, Masato [Inspection Development Company Ltd., Tokai, Ibaraki (Japan)

    2002-06-01

    The dissolution rate of high Pu content MOX fuel into nitric acid was measured as a function of Pu content. MOX fuel samples, pressed and sintered, were dissolved in 7 M of boiling nitric acid, and the dissolution rate was measured by analyzing the Pu and U concentration in the solution. The dissolution rate of MOX fuel tended to decrease with the increase in the Pu content and was reduced after 6 hours of dissolution. These results agreed well with previous ones, but the dissolution rate was 3-6 times faster than those. It is estimated that the cause of this difference was due to underestimation of the surface area of MOX fuel powder and the difference of the MOX O/M ratio. (author)

  3. [Study of age and sex dependance in renal clearances with radioisotopes (author's transl)].

    Science.gov (United States)

    Schernthaner, G; Erd, W; Ludwig, H; Sinzinger, H; Höfer, R

    1976-03-01

    In 85 patients between 15 and 95 years of age (40 male patients and 45 females) without any signs of renal disease (concentration of serum creatinine below 1,4 mg/100ml, normal diastolic blood pressure and normal urine analysis) a highly significant negative correlation was found between glomerular filtration rate (GFR, determined by 51Cr-EDTA - slope-clearance) and renal plasma flow (RPF, determined by 131J-oJHS-iodinehippuricacid-totalclearance) on one side and age on the other. Beginning with a basic value of 160 ml in males and 144 ml in females for GFR, the average decrease per year was 1,2 ml/1,0 ml respectively. The basis value of RPF was 854 ml for males and 673 ml for females, the decrease per year was 5,4 ml in men and 2,9 ml in women. The importance of physiological diminution of clearance values in elderly patients and its consequences for therapy are discussed. The more exact and methodically simpler 51Cr-EDTA-slope-clearance without urine collection should be used instead of the somewhat inaccurate determination of endogenous creatinine clearance especially in older patients.

  4. Methanol conversion in high-rate anaerobic reactors

    NARCIS (Netherlands)

    Weijma, J.; Stams, A.J.M.

    2001-01-01

    An overview on methanol conversion in high-rate anaerobic reactors is presented, with the focus on technological as well as microbiological aspects. The simple C1-compound methanol can be degraded anaerobically in a complex way, in which methanogens, sulfate reducing bacteria and homoacetogens

  5. READOUT ELECTRONICS FOR A HIGH-RATE CSC DETECTOR

    Energy Technology Data Exchange (ETDEWEB)

    OCONNOR,P.; GRATCHEV,V.; KANDASAMY,A.; POLYCHRONAKOS,V.; TCHERNIATINE,V.; PARSONS,J.; SIPPACH,W.

    1999-09-25

    A readout system for a high-rate muon Cathode Strip Chamber (CSC) is described. The system, planned for use in the forward region of the ATLAS muon spectrometer, uses two custom CMOS integrated circuits to achieve good position resolution at a flux of up to 2,500 tracks/cm{sup 2}/s.

  6. Childhood Onset Schizophrenia: High Rate of Visual Hallucinations

    Science.gov (United States)

    David, Christopher N.; Greenstein, Deanna; Clasen, Liv; Gochman, Pete; Miller, Rachel; Tossell, Julia W.; Mattai, Anand A.; Gogtay, Nitin; Rapoport, Judith L.

    2011-01-01

    Objective: To document high rates and clinical correlates of nonauditory hallucinations in childhood onset schizophrenia (COS). Method: Within a sample of 117 pediatric patients (mean age 13.6 years), diagnosed with COS, the presence of auditory, visual, somatic/tactile, and olfactory hallucinations was examined using the Scale for the Assessment…

  7. High Reported Spontaneous Stuttering Recovery Rates: Fact or Fiction?

    Science.gov (United States)

    Ramig, Peter R.

    1993-01-01

    Contact after 6 to 8 years with families of 21 children who were diagnosed as stuttering but did not receive fluency intervention services found that almost all subjects still had a stuttering problem. Results dispute the high spontaneous recovery rates reported in the literature and support the value of early intervention. (Author/DB)

  8. High deposition rate nanocrystalline silicon with enhanced homogeneity

    Energy Technology Data Exchange (ETDEWEB)

    Verkerk, Arjan; Rath, Jatindra K.; Schropp, Ruud [Section Nanophotonics-Physics of Devices, Debye Institute for Nanomaterials Science, Faculty of Science, Utrecht University, P.O. Box 80000, 3508 TA Utrecht (Netherlands)

    2010-03-15

    High rate growth of hydrogenated nanocrystalline silicon (nc-Si:H) brings additional challenges for the homogeneity in the growth direction, since the start-up effects affect a larger portion of the film, and the very high degree of depletion increases the influence of back diffusion from the inactive region into the plasma zone. It was calculated that back diffusion plays a role in the regime for high deposition rate (4.5 nm/s) via the residence time for particles in the plasma and the corresponding diffusion length for silane from outside the plasma. The stabilization time for back diffusion was derived and found to be on the order of tens of seconds. Experiment showed that the incubation layer for nc-Si:H is very thick in films deposited at a high rate compared to films deposited in a regime of lower deposition rate. The use of a hydrogen plasma start greatly reduced this incubation layer. Further control of the crystalline fraction could be achieved via slight reduction of the degree of depletion via the silane flow. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  9. Advances in high rate anaerobic treatment: staging of reactor systems.

    NARCIS (Netherlands)

    Lier, van J.B.; Zee, van der F.P.; Tan, N.C.G.; Rebac, S.; Kleerebezem, R.

    2001-01-01

    Anaerobic wastewater treatment (AnWT) is considered as the most cost-effective solution for organically polluted industrial waste streams. Particularly the development of high-rate systems, in which hydraulic retention times are uncoupled from solids retention times, has led to a world-wide acceptan

  10. Adapting high-rate anaerobic treatment to Middle East conditions

    NARCIS (Netherlands)

    Mahmoud, N.A.; Zeeman, G.; Lier, van J.B.

    2008-01-01

    High-rate anaerobic technologies offer cost-effective solutions for sewage treatment in the Middle East and Palestine in particular. The sewage characteristics in Palestine are quite different from the values elsewhere and show solids contents of more than 1000 mg chemical oxygen demand (COD)ss/L

  11. Binary interactions with high accretion rates onto main sequence stars

    Science.gov (United States)

    Shiber, Sagiv; Schreier, Ron; Soker, Noam

    2016-07-01

    Energetic outflows from main sequence stars accreting mass at very high rates might account for the powering of some eruptive objects, such as merging main sequence stars, major eruptions of luminous blue variables, e.g., the Great Eruption of Eta Carinae, and other intermediate luminosity optical transients (ILOTs; red novae; red transients). These powerful outflows could potentially also supply the extra energy required in the common envelope process and in the grazing envelope evolution of binary systems. We propose that a massive outflow/jets mediated by magnetic fields might remove energy and angular momentum from the accretion disk to allow such high accretion rate flows. By examining the possible activity of the magnetic fields of accretion disks, we conclude that indeed main sequence stars might accrete mass at very high rates, up to ≈ 10-2 M ⊙ yr-1 for solar type stars, and up to ≈ 1 M ⊙ yr-1 for very massive stars. We speculate that magnetic fields amplified in such extreme conditions might lead to the formation of massive bipolar outflows that can remove most of the disk's energy and angular momentum. It is this energy and angular momentum removal that allows the very high mass accretion rate onto main sequence stars.

  12. Understanding High School Graduation Rates in the District of Columbia

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  13. Understanding High School Graduation Rates in New Mexico

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  14. Understanding High School Graduation Rates in Rhode Island

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  15. Understanding High School Graduation Rates in South Dakota

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  16. Understanding High School Graduation Rates in West Virginia

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  17. Understanding High School Graduation Rates in North Carolina

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  18. Understanding High School Graduation Rates in South Carolina

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  19. Understanding High School Graduation Rates in North Dakota

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  20. Understanding High School Graduation Rates in New York

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  1. Understanding High School Graduation Rates in the United States

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  2. Understanding High School Graduation Rates in New Hampshire

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  3. Understanding High School Graduation Rates in New Jersey

    Science.gov (United States)

    Alliance for Excellent Education, 2009

    2009-01-01

    Graduation rates are a fundamental indicator of whether or not the nation's public school system is doing what it is intended to do: enroll, engage, and educate youth to be productive members of society. Since almost 90 percent of the fastest-growing and highest-paying jobs require some postsecondary education, having a high school diploma and the…

  4. 肌酐清除率对大剂量甲氨蝶呤化疗中血药浓度的影响%Influence of creatinine clearance on serum methotrexate concentration in high-dose methotrexate therapy

    Institute of Scientific and Technical Information of China (English)

    林晓雯; 邵宏; 聂小燕; 孙迎琪; 张乐萍; 李玉珍; 顾健

    2009-01-01

    AIM: To study the influence of creati-nine clearance on serum methotrexate ( MTX) concentration in high-dose methotrexate ( HDMTX) therapy. METHODS: The data was collected from 44 children who were diagnosed of acute lymphocytic leukemia (ALL) or non-Hodgkin lymphoma (NHL), and were administered with 106 doses of HDMTX from Feb, 2006 to May, 2008. The association between creatinine clearance and serum methotrexate concentration at 24 and 42 h were retrospectively analyzed, by SPSS 12.0 format. RESULTS: There was a significant correlation between creatinine clearance and 24 h serum methotrexate concentration (P 0.05) . CONCLUSION: Creatinine clearance can be related with 24 h serum methotrexate concentration, and can be referenced in estimating 24 h serum methotrexate concentration .%目的:研究肌酐清除率对于大剂量甲氨蝶呤(HDMTX)化疗中甲氨蝶呤(MTX)血药浓度的影响.方法:收集2006年2月至2008年5月住院期间使用HDMTX化疗方案化疗的44名急性淋巴细胞白血病或非霍奇金淋巴瘤患儿共106次化疗资料,使用SPSS 12.0版本回顾性地分析了肌酐清除率和24、42 h的血药浓度的相关性.结果:肌酐清除率和24 h血药浓度有显著相关性(P<0.05).肌酐清除率和42 h血药浓度无相关性(P>0.05).结论:肌酐清除率对于24 h MTX血药浓度有影响,对于预计24 h MTX血药浓度有一定参考价值.

  5. Mechanisms of high heart rate variability: a fresh look

    Directory of Open Access Journals (Sweden)

    Vladimir A. Lukyanchenko

    2016-05-01

    Full Text Available Consideration is being given herein to some mechanisms of high heart rate variability (high HRV, which cannot be attributed to sports exercise loading. The mechanism responsible for high HRV is explained as that resulted from the continuous performance (opening and closure of arteriovenous anastomoses in different organs and systems in a human organism. An assessment of this phenomenon is given herein from the point of view of a practicing physician who treats regularly patients with already established clinical diagnoses and those without an established nosological profile according to International Statistical Classification of Diseases and Related Health Problems 10th Revision.

  6. OFDM-based Low-voltage Powerline High Rate Communication

    Institute of Scientific and Technical Information of China (English)

    ZHANG You-bing(张有兵); CHENG Shi-jie(程时杰); Joseph Nguimbis; XIONG Lan(熊兰)

    2004-01-01

    Based on the experimental results, a simplified model for low-voltage powerline used as a high frequency communication channel is presented. With this model, the Orthogonal Frequency Division Multiplexing (OFDM) based high rate digital communication over low-voltage powerline is analyzed and simulated. The capability of thc signal transmission system in overcoming multi-path interference and selection of the system parameters are discussed. And time-domain simulation is carried out to investigate the transmission capability of the OFDM cammunication system for different mapping schemes and transmission power levels. Simulation results show that it is possible to realize high rate digital communication over iow-voltage powerliue using OFDM when the transmitted power is large enough.

  7. High strain rate behavior of pure metals at elevated temperature

    Science.gov (United States)

    Testa, Gabriel; Bonora, Nicola; Ruggiero, Andrew; Iannitti, Gianluca; Domenico, Gentile

    2013-06-01

    In many applications and technology processes, such as stamping, forging, hot working etc., metals and alloys are subjected to elevated temperature and high strain rate deformation process. Characterization tests, such as quasistatic and dynamic tension or compression test, and validation tests, such as Taylor impact and DTE - dynamic tensile extrusion -, provide the experimental base of data for constitutive model validation and material parameters identification. Testing material at high strain rate and temperature requires dedicated equipment. In this work, both tensile Hopkinson bar and light gas gun where modified in order to allow material testing under sample controlled temperature conditions. Dynamic tension tests and Taylor impact tests, at different temperatures, on high purity copper (99.98%), tungsten (99.95%) and 316L stainless steel were performed. The accuracy of several constitutive models (Johnson and Cook, Zerilli-Armstrong, etc.) in predicting the observed material response was verified by means of extensive finite element analysis (FEA).

  8. A High Rate Tension Device for Characterizing Brain Tissue

    CERN Document Server

    Rashid, Badar; Gilchrist, Michael; 10.1177/1754337112436900

    2013-01-01

    The mechanical characterization of brain tissue at high loading velocities is vital for understanding and modeling Traumatic Brain Injury (TBI). The most severe form of TBI is diffuse axonal injury (DAI) which involves damage to individual nerve cells (neurons). DAI in animals and humans occurs at strains > 10% and strain rates > 10/s. The mechanical properties of brain tissues at these strains and strain rates are of particular significance, as they can be used in finite element human head models to accurately predict brain injuries under different impact conditions. Existing conventional tensile testing machines can only achieve maximum loading velocities of 500 mm/min, whereas the Kolsky bar apparatus is more suitable for strain rates > 100/s. In this study, a custom-designed high rate tension device is developed and calibrated to estimate the mechanical properties of brain tissue in tension at strain rates < 90/s, while maintaining a uniform velocity. The range of strain can also be extended to 100% de...

  9. Systematic Uncertainties in High-Rate Germanium Data

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, Andrew J.; Fast, James E.; Fulsom, Bryan G.; Pitts, William K.; VanDevender, Brent A.; Wood, Lynn S.

    2016-10-06

    For many nuclear material safeguards inspections, spectroscopic gamma detectors are required which can achieve high event rates (in excess of 10^6 s^-1) while maintaining very good energy resolution for discrimination of neighboring gamma signatures in complex backgrounds. Such spectra can be useful for non-destructive assay (NDA) of spent nuclear fuel with long cooling times, which contains many potentially useful low-rate gamma lines, e.g., Cs-134, in the presence of a few dominating gamma lines, such as Cs-137. Detectors in use typically sacrifice energy resolution for count rate, e.g., LaBr3, or visa versa, e.g., CdZnTe. In contrast, we anticipate that beginning with a detector with high energy resolution, e.g., high-purity germanium (HPGe), and adapting the data acquisition for high throughput will be able to achieve the goals of the ideal detector. In this work, we present quantification of Cs-134 and Cs-137 activities, useful for fuel burn-up quantification, in fuel that has been cooling for 22.3 years. A segmented, planar HPGe detector is used for this inspection, which has been adapted for a high-rate throughput in excess of 500k counts/s. Using a very-high-statistic spectrum of 2.4*10^11 counts, isotope activities can be determined with very low statistical uncertainty. However, it is determined that systematic uncertainties dominate in such a data set, e.g., the uncertainty in the pulse line shape. This spectrum offers a unique opportunity to quantify this uncertainty and subsequently determine required counting times for given precision on values of interest.

  10. Highly variable rates of genome rearrangements between hemiascomycetous yeast lineages.

    Directory of Open Access Journals (Sweden)

    2006-03-01

    Full Text Available Hemiascomycete yeasts cover an evolutionary span comparable to that of the entire phylum of chordates. Since this group currently contains the largest number of complete genome sequences it presents unique opportunities to understand the evolution of genome organization in eukaryotes. We inferred rates of genome instability on all branches of a phylogenetic tree for 11 species and calculated species-specific rates of genome rearrangements. We characterized all inversion events that occurred within synteny blocks between six representatives of the different lineages. We show that the rates of macro- and microrearrangements of gene order are correlated within individual lineages but are highly variable across different lineages. The most unstable genomes correspond to the pathogenic yeasts Candida albicans and Candida glabrata. Chromosomal maps have been intensively shuffled by numerous interchromosomal rearrangements, even between species that have retained a very high physical fraction of their genomes within small synteny blocks. Despite this intensive reshuffling of gene positions, essential genes, which cluster in low recombination regions in the genome of Saccharomyces cerevisiae, tend to remain syntenic during evolution. This work reveals that the high plasticity of eukaryotic genomes results from rearrangement rates that vary between lineages but also at different evolutionary times of a given lineage.

  11. Clearance of beta-2-microglobulin and middle molecules in haemodiafiltration.

    Science.gov (United States)

    Tattersall, James

    2007-01-01

    Middle molecules, consisting mostly of peptides and small proteins with molecular weight the range of 500-60,000 Da, accumulate in renal failure and contribute to the uraemic toxic state. Beta2-microglobulin (beta2-MG) with a molecular weight of 11,000 is considered representative of these middle molecules. These solutes are not well cleared by low-flux dialysis. High-flux dialysis will clear middle molecules, partly by internal filtration. This convective component of high-flux dialysis can be enhanced in a predictable way by haemodiafiltration (HDF). The convective and diffusive clearance rates of any middle molecule across any haemodiafilter can be predicted from known or measurable factors such as its sieving coefficient, bound fraction and molecular weight. The removal of middle molecules is also influenced by factors within the patient. Beta2-MG is distributed within the extracellular fluid. During HDF, beta2-MG must transfer into the intravascular compartment across the capillary walls. This transcapillary transfer at a rate of approximately 100 ml/min slows beta2-MG removal from the body. Continuing transfer after the end of a treatment session results in a significant rebound of beta2-MG levels. This intercompartment transfer and its effect on beta2-MG clearance and concentration can be predicted by a 2-compartment model. By extrapolation, the behaviour of other middle molecules can be predicted. The 2-compartment model, which takes non-dialytic beta2-MG clearance at a rate of 3 ml/min and beta2-MG generation at a rate of 0.1 mg/min into account, can predict the effect of any HDF schedule on beta2-MG levels. Low-flux dialysis results in a beta2-MG level of around 40 mg/l. Three times weekly, 4-hour HDF can reduce beta2-MG levels to around 20 mg/l. Long (nocturnal) HDF can reduce beta2-MG levels to around 10 mg/l, compared to physiological levels of less than 5 mg/l.

  12. Demonstration of a high repetition rate capillary discharge waveguide

    Energy Technology Data Exchange (ETDEWEB)

    Gonsalves, A. J., E-mail: ajgonsalves@lbl.gov; Pieronek, C.; Daniels, J.; Bulanov, S. S.; Waldron, W. L.; Mittelberger, D. E.; Leemans, W. P. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Liu, F.; Antipov, S.; Butler, J. E. [Euclid TechLabs, Gaithersburg, Maryland 20879 (United States); Bobrova, N. A.; Sasorov, P. V. [Keldysh Institute of Applied Mathematics, Moscow (Russian Federation)

    2016-01-21

    A hydrogen-filled capillary discharge waveguide operating at kHz repetition rates is presented for parameters relevant to laser plasma acceleration (LPA). The discharge current pulse was optimized for erosion mitigation with laser guiding experiments and MHD simulation. Heat flow simulations and measurements showed modest temperature rise at the capillary wall due to the average heat load at kHz repetition rates with water-cooled capillaries, which is promising for applications of LPAs such as high average power radiation sources.

  13. Physical characteristics of the Selectron high dose rate intracavitary afterloader

    Energy Technology Data Exchange (ETDEWEB)

    Chenery, S.G.A.; Pla, M.; Podgorsak, E.B. (Royal Victoria Hospital, Montreal, Quebec (Canada); McGill Univ., Montreal, Quebec (Canada))

    1985-08-01

    The physics measurements on a Selectron high dose-rate afterloading cobalt-60 unit are reported. The installation was found to be acceptable from the standpoint of radiation safety and cost effectiveness; hospital bed space was saved as treatment could be on an outpatient basis. A source calibration 4% higher than the value stated by the manufacturer was obtained. Measurement of the ratio of exposure rate in water to that in air confirmed the calibration and the applicability of correction factors for routine clinical dosimetry recommended in the literature.

  14. Nanocrystalline silicon prepared at high growth rate using helium dilution

    Indian Academy of Sciences (India)

    Koyel Bhattacharya; Debajyoti Das

    2008-06-01

    Growth and optimization of the nanocrystalline silicon (nc-Si : H) films have been studied by varying the electrical power applied to the helium diluted silane plasma in RF glow discharge. Wide optical gap and conducting intrinsic nanocrystalline silicon network of controlled crystalline volume fraction and oriented crystallographic lattice planes have been obtained at a reasonably high growth rate from helium diluted silane plasma, without using hydrogen. Improving crystallinity in the network comprising ∼ 10 nm Si-nanocrystallites and contributing optical gap widening, conductivity ascending and that obtained during simultaneous escalation of the deposition rate, promises significant technological impact.

  15. Design of High-ground-clearance Narrow-rubber-pedrail-type Running System for Paddy Field and Upland%高地隙窄形橡胶履带式水旱兼用行走系统设计

    Institute of Scientific and Technical Information of China (English)

    邢全道; 何瑞银; 何彦平; 安波; 刘天星; 王媛媛; 邢艳红; 徐高明

    2013-01-01

    A high-ground-clearance narrow -rubber-pedrail-type running system for paddy field and dry upland was de-veloped, which was especially suitable for plant protection work of paddy field .The working principle of this running system was an-alyzed.The pedrail, driving wheel or guiding wheel , supporting bearing and other key parts were designed and calculated .The per-formance tests showed that the system had stable working property with the ground clearance of 1 m, and prevented the wheels from sinking into the deep earth, so that few seedlings were squashed .%  研制了一种高地隙水旱兼用行走系统,特别适用于水稻田植保作业,分析了其工作原理,并对履带、驱动轮或导向轮、支撑轴承座等关键部件进行了设计计算,通过性能试验表明:该行走系统工作性能稳定,地隙达1 m,防陷深,压苗少。

  16. Determination of Tensile Properties of Polymers at High Strain Rates

    Directory of Open Access Journals (Sweden)

    Major Z.

    2010-06-01

    Full Text Available In the field of high rate testing of polymers the measured properties are highly dependent on the applied methodology. Hence, the test setup as whole but in particular also the geometrical type of specimen plays a decisive role. The widely used standard for the determination of tensile properties of polymers (ISO527-2 was extended by a novel standard (ISO18872:2007, which is targeted on the determination of tensile properties at high strain rates. In this standard also a novel specimen shape is proposed. Hand in hand with the introduction of new specimen geometry the question of comparability arises. To point out the differences in stress-strain response of the ISO18872 specimen and the ISO527-2 multipurpose specimen tensile tests over a wide loading rate range were conducted in this paper. A digital image correlation system in combination with a high speed camera was used to characterize the local material behaviour. Different parameters like nominal stress, true stress, nominal strain, true strain as well as volumetric strain were determined and used to compare the two specimen geometries.

  17. High Pressure Burn Rate Measurements on an Ammonium Perchlorate Propellant

    Energy Technology Data Exchange (ETDEWEB)

    Glascoe, E A; Tan, N

    2010-04-21

    High pressure deflagration rate measurements of a unique ammonium perchlorate (AP) based propellant are required to design the base burn motor for a Raytheon weapon system. The results of these deflagration rate measurements will be key in assessing safety and performance of the system. In particular, the system may experience transient pressures on the order of 100's of MPa (10's kPSI). Previous studies on similar AP based materials demonstrate that low pressure (e.g. P < 10 MPa or 1500 PSI) burn rates can be quite different than the elevated pressure deflagration rate measurements (see References and HPP results discussed herein), hence elevated pressure measurements are necessary in order understand the deflagration behavior under relevant conditions. Previous work on explosives have shown that at 100's of MPa some explosives will transition from a laminar burn mechanism to a convective burn mechanism in a process termed deconsolidative burning. The resulting burn rates that are orders-of-magnitude faster than the laminar burn rates. Materials that transition to the deconsolidative-convective burn mechanism at elevated pressures have been shown to be considerably more violent in confined heating experiments (i.e. cook-off scenarios). The mechanisms of propellant and explosive deflagration are extremely complex and include both chemical, and mechanical processes, hence predicting the behavior and rate of a novel material or formulation is difficult if not impossible. In this work, the AP/HTPB based material, TAL-1503 (B-2049), was burned in a constant volume apparatus in argon up to 300 MPa (ca. 44 kPSI). The burn rate and pressure were measured in-situ and used to calculate a pressure dependent burn rate. In general, the material appears to burn in a laminar fashion at these elevated pressures. The experiment was reproduced multiple times and the burn rate law using the best data is B = (0.6 {+-} 0.1) x P{sup (1.05{+-}0.02)} where B is the burn

  18. High clearance phenotyping systems for season-long measurement of corn, sorghum and other row crops to complement unmanned aerial vehicle systems

    Science.gov (United States)

    Murray, Seth C.; Knox, Leighton; Hartley, Brandon; Méndez-Dorado, Mario A.; Richardson, Grant; Thomasson, J. Alex; Shi, Yeyin; Rajan, Nithya; Neely, Haly; Bagavathiannan, Muthukumar; Dong, Xuejun; Rooney, William L.

    2016-05-01

    The next generation of plant breeding progress requires accurately estimating plant growth and development parameters to be made over routine intervals within large field experiments. Hand measurements are laborious and time consuming and the most promising tools under development are sensors carried by ground vehicles or unmanned aerial vehicles, with each specific vehicle having unique limitations. Previously available ground vehicles have primarily been restricted to monitoring shorter crops or early growth in corn and sorghum, since plants taller than a meter could be damaged by a tractor or spray rig passing over them. Here we have designed two and already constructed one of these self-propelled ground vehicles with adjustable heights that can clear mature corn and sorghum without damage (over three meters of clearance), which will work for shorter row crops as well. In addition to regular RGB image capture, sensor suites are incorporated to estimate plant height, vegetation indices, canopy temperature and photosynthetically active solar radiation, all referenced using RTK GPS to individual plots. These ground vehicles will be useful to validate data collected from unmanned aerial vehicles and support hand measurements taken on plots.

  19. Airway clearance strategies for the pediatric patient.

    Science.gov (United States)

    Davidson, Kathryn L

    2002-07-01

    Clinicians who care for cystic fibrosis (CF) patients have many techniques to choose from to facilitate mucus clearance. Little has been published about when to introduce the various techniques and in what order to teach them. Debates have occurred over these issues in the CF community, and there is now consensus on some topics. It is very important to teach adherence to therapy at an early age. Adherence to an airway clearing regimen assists in maintaining good pulmonary function in CF patients. Knowing when and how to introduce airway clearance techniques beyond chest physiotherapy (CPT) is clinically relevant and useful. A 5-position modified CPT routine can be used with infants and children, and it takes less time and may improve adherence. Infants and toddlers can be taught breathing games that eventually lead them to perform diaphragmatic breathing and huffing. Once they have mastered diaphragmatic breathing and huffing, children can be taught the active cycle of breathing technique. Modified CPT can be phased out at that point. Positive expiratory pressure therapy can usually be introduced around 6-7 years of age. High-frequency chest wall oscillation, oscillating positive expiratory pressure, and autogenic drainage all follow. CF patients should be given every opportunity to learn and master various techniques to promote mucus clearance.

  20. Multiplexed CV quantum teleportation for high rates in quantum communication

    CERN Document Server

    Christ, Andreas; Silberhorn, Christine

    2012-01-01

    A major challenge of today's quantum communication systems lies in the transmission of quantum information with high rates over long distances in the presence of unavoidable losses. Thereby the achievable quantum communication rate is fundamentally limited by the amount of energy that can be transmitted per use of the channel. It is hence vital to develop quantum communication protocols which encode quantum information as energy efficiently as possible. To this aim we investigate continuous-variable quantum teleportation as a method of distributing quantum information. We explore the possibility to encode information on multiple optical modes and derive upper and lower bounds on the achievable quantum channel capacities. This analysis enables us to benchmark single-mode vs. multi-mode entanglement resources. Our research reveals that multiplexing does not only feature an enhanced energy efficiency, significantly increasing the achievable quantum communication rates in comparison to single-mode coding, but als...

  1. High data rate recording: Moving to 2 Gbit/s

    Science.gov (United States)

    Taratorin, A.; Yuan, S.; Nikitin, V.

    2003-05-01

    High data rate recording can be achieved using fast write drivers and fast heads. Advanced short-yoke write heads and write drivers with 450 ps rise time and programmable current overshoot were used to study recording at data rates up to 2 Gbit/s. The head flux rise time causes shifts of recorded transitions. It is well known that current overshoot helps to overcome bandwidth limitations in the write driver, interconnects, and write head. However, excessive overshoot may cause pattern-dependent transition shifts and significant distortions of recorded transitions. We present the data rate performance of short-yoke recording heads, analysis of nonlinear pattern-dependent distortions, and optimization of the write current wave form in the 1-2 Gbit/s range. Simple dibit and tribit patterns were recorded at 2 Gbit/s. Low-distortion recording for arbitrary data patterns was demonstrated at 1.6 Gbit/s after optimization of write current overshoot.

  2. Dynamic High-Temperature Characterization of an Iridium Alloy in Compression at High Strain Rates

    Energy Technology Data Exchange (ETDEWEB)

    Song, Bo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Experimental Environment Simulation Dept.; Nelson, Kevin [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Mechanics of Materials Dept.; Lipinski, Ronald J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Nuclear Fuel Cycle Technology Dept.; Bignell, John L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Structural and Thermal Analysis Dept.; Ulrich, G. B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Radioisotope Power Systems Program; George, E. P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Radioisotope Power Systems Program

    2014-06-01

    Iridium alloys have superior strength and ductility at elevated temperatures, making them useful as structural materials for certain high-temperature applications. However, experimental data on their high-temperature high-strain-rate performance are needed for understanding high-speed impacts in severe elevated-temperature environments. Kolsky bars (also called split Hopkinson bars) have been extensively employed for high-strain-rate characterization of materials at room temperature, but it has been challenging to adapt them for the measurement of dynamic properties at high temperatures. Current high-temperature Kolsky compression bar techniques are not capable of obtaining satisfactory high-temperature high-strain-rate stress-strain response of thin iridium specimens investigated in this study. We analyzed the difficulties encountered in high-temperature Kolsky compression bar testing of thin iridium alloy specimens. Appropriate modifications were made to the current high-temperature Kolsky compression bar technique to obtain reliable compressive stress-strain response of an iridium alloy at high strain rates (300 – 10000 s-1) and temperatures (750°C and 1030°C). Uncertainties in such high-temperature high-strain-rate experiments on thin iridium specimens were also analyzed. The compressive stress-strain response of the iridium alloy showed significant sensitivity to strain rate and temperature.

  3. Numerical investigation of tip clearance effects on the performance of ducted propeller

    Science.gov (United States)

    Yongle, Ding; Baowei, Song; Peng, Wang

    2015-09-01

    Tip clearance loss is a limitation of the improvement of turbomachine performance. Previous studies show the Tip clearance loss is generated by the leakage flow through the tip clearance, and is roughly linearly proportional to the gap size. This study investigates the tip clearance effects on the performance of ducted propeller. The investigation was carried out by solving the Navier-Stokes equations with the commercial Computational Fluid Dynamic (CFD) code CFX14.5. These simulations were carried out to determine the underlying mechanisms of the tip clearance effects. The calculations were performed at three different chosen advance ratios. Simulation results showed that the tip loss slope was not linearly at high advance due to the reversed pressure at the leading edge. Three type of vortical structures were observed in the tip clearance at different clearance size.

  4. Investigation of high-rate lithium-thionyl chloride cells

    Science.gov (United States)

    Hayes, Catherine A.; Gust, Steven; Farrington, Michael D.; Lockwood, Judith A.; Donaldson, George J.

    Chemical analysis of a commercially produced high-rate D-size lithium-thionyl cell was carried out, as a function of rate of discharge (1 ohm and 5 ohms), depth of discharge, and temperature (25 C and -40 C), using specially developed methods for identifying suspected minor cell products or impurities which may effect cell performance. These methods include a product-retrieval system which involves solvent extraction to enhance the recovery of suspected semivolatile minor chemicals, and methods of quantitative GC analysis of volatile and semivolatile products. The nonvolatile products were analyzed by wet chemical methods. The results of the analyses indicate that the predominant discharge reaction in this cell is 4Li + 2SOCl2 going to 4LiCl + S + SO2, with SO2 formation decreasing towards the end of cell life (7 to 12 Ah). The rate of discharge had no effect on the product distribution. Upon discharge of the high-rate cell at -40 C, one cell exploded, and all others exhibited overheating and rapid internal pressure rise when allowed to warm up to room temperature.

  5. HIGH RATES OF EVOLUTION PRECEDED THE ORIGIN OF BIRDS

    Science.gov (United States)

    Puttick, Mark N; Thomas, Gavin H; Benton, Michael J; Polly, P David

    2014-01-01

    The origin of birds (Aves) is one of the great evolutionary transitions. Fossils show that many unique morphological features of modern birds, such as feathers, reduction in body size, and the semilunate carpal, long preceded the origin of clade Aves, but some may be unique to Aves, such as relative elongation of the forelimb. We study the evolution of body size and forelimb length across the phylogeny of coelurosaurian theropods and Mesozoic Aves. Using recently developed phylogenetic comparative methods, we find an increase in rates of body size and body size dependent forelimb evolution leading to small body size relative to forelimb length in Paraves, the wider clade comprising Aves and Deinonychosauria. The high evolutionary rates arose primarily from a reduction in body size, as there were no increased rates of forelimb evolution. In line with a recent study, we find evidence that Aves appear to have a unique relationship between body size and forelimb dimensions. Traits associated with Aves evolved before their origin, at high rates, and support the notion that numerous lineages of paravians were experimenting with different modes of flight through the Late Jurassic and Early Cretaceous. PMID:24471891

  6. High frame rate measurements of semiconductor pixel detector readout IC

    Science.gov (United States)

    Szczygiel, R.; Grybos, P.; Maj, P.

    2012-07-01

    We report on high count rate and high frame rate measurements of a prototype IC named FPDR90, designed for readouts of hybrid pixel semiconductor detectors used for X-ray imaging applications. The FPDR90 is constructed in 90 nm CMOS technology and has dimensions of 4 mm×4 mm. Its main part is a matrix of 40×32 pixels with 100 μm×100 μm pixel size. The chip works in the single photon counting mode with two discriminators and two 16-bit ripple counters per pixel. The count rate per pixel depends on the effective CSA feedback resistance and can be set up to 6 Mcps. The FPDR90 can operate in the continuous readout mode, with zero dead time. Due to the architecture of digital blocks in pixel, one can select the number of bits read out from each counter from 1 to 16. Because in the FPDR90 prototype only one data output is available, the frame rate is 9 kfps and 72 kfps for 16 bits and 1 bit readout, respectively (with nominal clock frequency of 200 MHz).

  7. High frame rate measurements of semiconductor pixel detector readout IC

    Energy Technology Data Exchange (ETDEWEB)

    Szczygiel, R., E-mail: robert.szczygiel@agh.edu.pl [AGH University of Science and Technology, Department of Measurement and Instrumentation, Al. Mickiewicza 30, 30-059 Cracow (Poland); Grybos, P.; Maj, P. [AGH University of Science and Technology, Department of Measurement and Instrumentation, Al. Mickiewicza 30, 30-059 Cracow (Poland)

    2012-07-11

    We report on high count rate and high frame rate measurements of a prototype IC named FPDR90, designed for readouts of hybrid pixel semiconductor detectors used for X-ray imaging applications. The FPDR90 is constructed in 90 nm CMOS technology and has dimensions of 4 mm Multiplication-Sign 4 mm. Its main part is a matrix of 40 Multiplication-Sign 32 pixels with 100 {mu}m Multiplication-Sign 100 {mu}m pixel size. The chip works in the single photon counting mode with two discriminators and two 16-bit ripple counters per pixel. The count rate per pixel depends on the effective CSA feedback resistance and can be set up to 6 Mcps. The FPDR90 can operate in the continuous readout mode, with zero dead time. Due to the architecture of digital blocks in pixel, one can select the number of bits read out from each counter from 1 to 16. Because in the FPDR90 prototype only one data output is available, the frame rate is 9 kfps and 72 kfps for 16 bits and 1 bit readout, respectively (with nominal clock frequency of 200 MHz).

  8. Small cryptopredators contribute to high predation rates on coral reefs

    Science.gov (United States)

    Goatley, Christopher H. R.; González-Cabello, Alonso; Bellwood, David R.

    2017-03-01

    Small fishes suffer high mortality rates on coral reefs, primarily due to predation. Although studies have identified the predators of early post-settlement fishes, the predators of small cryptobenthic fishes remain largely unknown. We therefore used a series of mesocosm experiments with natural habitat and cryptobenthic fish communities to identify the impacts of a range of small potential predators, including several invertebrates, on prey fish populations. While there was high variability in predation rates, many members of the cryptobenthic fish community act as facultative cryptopredators, being prey when small and piscivores when larger. Surprisingly, we also found that smashing mantis shrimps may be important fish predators. Our results highlight the diversity of the predatory community on coral reefs and identify previously unknown trophic links in these complex ecosystems.

  9. Complex pulsing schemes for high frame rate imaging

    DEFF Research Database (Denmark)

    Misaridis, Thanassis; Fink, Mathias; Jensen, Jørgen Arendt

    2002-01-01

    High frame rate ultrasound imaging can be achieved by simultaneous transmission of multiple focused beams along different directions. However, image quality degrades by the interference among beams. An alternative approach is to transmit spherical waves of a basic short pulse with frequency coding...... with linear frequency modulation along the transducer elements, that cover the 70% fractional bandwidth of the 7 MHz transducer. The resulted images (after beamforming and matched filtering) show an axial resolution at the same order as in conventional pulse excitation and axial sidelobes down to -45 d......B. With the proposed imaging strategy of pulse train excitation, a whole image can be formed with only two emissions, making it possible to obtain high quality images at a frame rate of 20 to 25 times higher than that of conventional phased array imaging...

  10. Characteristics of Multiplexed Grooved Nozzles for High Flow Rate Electrospray

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyoung Tae; Kim, Woo Jin; Kim, Sang Soo [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2007-10-15

    The electrospray operated in the cone-jet mode can generate highly charged micro droplets in an almost uniform size at flow rates. Therefore, the multiplexing system which can retain the characteristics of the cone-jet mode is inevitable for the electrospray application. This experiment reports the multiplexed grooved nozzle system with the extractor. The effects of the grooves and the extractor on the performance of the electrospray were evaluated through experiments. Using the grooved nozzle, the stable cone-jet mode can be achieved at the each groove in the grooved mode. Furthermore, the number of nozzles per unit area is increased by the extractor. The multiplexing density is 12 jets per cm{sup 2} at 30 mm distance from the nozzle tip to the ground plate. The multiplexing system for the high flow rate electrospray is realized with the extractor which can diminish the space charge effect without sacrificing characteristics of the cone-jet mode.

  11. Distribution of streaming rates into high-redshift galaxies

    CERN Document Server

    Goerdt, Tobias; Dekel, Avishai; Teyssier, Romain

    2015-01-01

    We study the accretion along streams from the cosmic web into high-redshift massive galaxies using three sets of AMR hydro-cosmological simulations. We find that the streams keep a roughly constant accretion rate as they penetrate into the halo centre. The mean accretion rate follows the mass and redshift dependence predicted for haloes by the EPS approximation, dM / dt is proportional to Mvir^{1.25} (1 + z)^{2.5}. The distribution of the accretion rates can well be described by a sum of two Gaussians, the primary corresponding to "smooth inflow" and the secondary to "mergers". The same functional form was already found for the distributions of specific star formation rates in observations. The mass fraction in the smooth component is 60 - 90 %, insensitive to redshift or halo mass. The simulations with strong feedback show clear signs of re-accretion due to recycling of galactic winds. The mean accretion rate for the mergers is a factor 2 - 3 larger than that of the smooth component. The standard deviation o...

  12. High-rate diamond deposition by microwave plasma CVD

    Science.gov (United States)

    Li, Xianglin

    In this dissertation, the growth of CVD (Chemical Vapor Deposition) diamond thin films is studied both theoretically and experimentally. The goal of this research is to deposit high quality HOD (Highly Oriented Diamond) films with a growth rate greater than 1 mum/hr. For the (100)-oriented HOD films, the growth rate achieved by the traditional process is only 0.3 mum/hr while the theoretical limit is ˜0.45 mum/hr. This research increases the growth rate up to 5.3 mum/hr (with a theoretical limit of ˜7 mum/hr) while preserving the crystal quality. This work builds a connection between the theoretical study of the CVD process and the experimental research. The study is extended from the growth of regular polycrystalline diamond to highly oriented diamond (HOD) films. For the increase of the growth rate of regular polycrystalline diamond thin films, a scaling growth model developed by Goodwin is introduced in details to assist in the understanding of the MPCVD (Microwave Plasma CVD) process. Within the Goodwin's scaling model, there are only four important sub-processes for the growth of diamond: surface modification, adsorption, desorption, and incorporation. The factors determining the diamond growth rate and film quality are discussed following the description of the experimental setup and process parameters. Growth rate and crystal quality models are reviewed to predict and understand the experimental results. It is shown that the growth rate of diamond can be increased with methane input concentration and the amount of atomic hydrogen (by changing the total pressure). It is crucial to provide enough atomic hydrogen to conserve crystal quality of the deposited diamond film. The experimental results demonstrate that for a fixed methane concentration, there is a minimum pressure for growth of good diamond. Similarly, for a fixed total pressure, there is a maximum methane concentration for growth of good diamond, and this maximum methane concentration increases

  13. The economics of landmine clearance in Afghanistan.

    Science.gov (United States)

    Harris, Geoff

    2002-03-01

    This paper presents an economic evaluation of landmine clearance in Afghanistan. The main benefits comprise increased agricultural output, saved transport time and running costs, saved human casualties and the saved costs of supporting refugees and displaced persons. An investment of US$100 million between 1988 and 1998 is estimated to provide annual benefits of $50.3 million per annum between 1999 and 2008. This translates into net present values of between $935 and $1,744 million, depending on the rate of discount used. This contrasts with the negative NPVs estimated for several other countries.

  14. High Strain Rate Experiments of Energetic Material Binder

    OpenAIRE

    Rangel Mendoza, Roberto; Harr, Michael; Chen, Weinong

    2016-01-01

    Energetic materials, in particular HMX, is widely used in many applications as polymer bonded explosives (PBX) and rocket propellant. However, when damaged, HMX is known to be an unstable substance which renders it a hazardous material and in some cases unreliable. Finding critical mechanical conditions at high rates that render various forms of energetic materials as unreliable would be vital to understand the effects that vibrations and compression forces have on energetic materials. A bett...

  15. Fast demographic traits promote high diversification rates of Amazonian trees

    OpenAIRE

    Baker, Timothy R.; Pennington, R. Toby; Magallon, Susana; Gloor, Emanuel; Laurance, William F.; Alexiades, Miguel; Alvarez, Esteban; Araujo, Alejandro; Arets, Eric J. M. M.; Aymard, Gerardo; de Oliveira, Atila Alves; Amaral, Iêda; Arroyo, Luzmila; Bonal, Damien; Roel J.W. Brienen

    2014-01-01

    The Amazon rain forest sustains the world's highest tree diversity, but it remains unclear why some clades of trees are hyperdiverse, whereas others are not. Using dated phylogenies, estimates of current species richness and trait and demographic data from a large network of forest plots, we show that fast demographic traits - short turnover times - are associated with high diversification rates across 51 clades of canopy trees. This relationship is robust to assuming that diversification rat...

  16. Data Feature Extraction for High-Rate 3-Phase Data

    Energy Technology Data Exchange (ETDEWEB)

    2016-10-18

    This algorithm processes high-rate 3-phase signals to identify the start time of each signal and estimate its envelope as data features. The start time and magnitude of each signal during the steady state is also extracted. The features can be used to detect abnormal signals. This algorithm is developed to analyze Exxeno's 3-phase voltage and current data recorded from refrigeration systems to detect device failure or degradation.

  17. High rate multiplicity detector for relativistic heavy-ion collisions

    Energy Technology Data Exchange (ETDEWEB)

    Beavis, D. [Brookhaven National Lab., Upton, NY (United States); Bennett, M.J. [Yale University, A.W. Wright Nuclear Structure Laboratory, New Haven, CT 06511 (United States); Carroll, J.B. [University of California at Los Angeles, Los Angeles, CA (United States); Chiba, J. [KEK National High Energy Physics, Tsukuba (Japan); Chikanian, A. [Yale University, A.W. Wright Nuclear Structure Laboratory, New Haven, CT 06511 (United States); Crawford, H.J. [University of California Space Sciences Laboratory, Berkeley, CA (United States); Cronqvist, M. [University of California Space Sciences Laboratory, Berkeley, CA (United States); Dardenne, Y. [University of California Space Sciences Laboratory, Berkeley, CA (United States); Debbe, R. [Brookhaven National Lab., Upton, NY (United States); Doke, T. [Waseda University, Science and Engineering Research Institute, Waseda (Japan); Engelage, J. [University of California Space Sciences Laboratory, Berkeley, CA (United States); Flores, I. [University of California Space Sciences Laboratory, Berkeley, CA (United States); Greiner, L. [University of California Space Sciences Laboratory, Berkeley, CA (United States); Hayano, R.S. [University of Tokyo, Tokyo (Japan); Hallman, T.J. [University of California at Los Angeles, Los Angeles, CA (United States); Heckman, H.H. [Lawrence Berkeley Lab., CA (United States); Kashiwagi, T. [Waseda University, Science and Engineering Research Institute, Waseda (Japan); Kikuchi, J. [Waseda University, Science and Engineering Research Institute, Waseda (Japan); Kumar, B.S. [Yale University, A.W. Wright Nuclear Structure Laboratory, New Haven, CT 06511 (United States); Kuo, C. [University of California Space Sciences Laboratory, Berkeley, CA (United States); Lindstrom, P.J. [Lawrence Berkeley Lab., CA (United States); Mitchell, J.W. [Universities Space Research Association/Goddard Space Flight Center, Greenbelt, MD (United States); Nagamiya, S.; E878 Collaboration

    1995-04-21

    We have constructed and operated a detector to measure the multiplicity of secondary particles produced in nucleus-nucleus collisions in the E878 experiment at the Brookhaven National Laboratory AGS facility. We describe the operation and performance of the detector in a high rate Au beam environment, and interpret the multiplicity data in terms of the impact parameters of the nucleus-nucleus collisions. ((orig.)).

  18. High-rate measurement-device-independent quantum cryptography

    DEFF Research Database (Denmark)

    Pirandola, Stefano; Ottaviani, Carlo; Spedalieri, Gaetana

    2015-01-01

    Quantum cryptography achieves a formidable task - the remote distribution of secret keys by exploiting the fundamental laws of physics. Quantum cryptography is now headed towards solving the practical problem of constructing scalable and secure quantum networks. A significant step in this direction...... than those currently achieved. Our protocol could be employed to build high-rate quantum networks where devices securely connect to nearby access points or proxy servers....

  19. Twinning in copper deformed at high strain rates

    Indian Academy of Sciences (India)

    S Cronje; R E Kroon; W D Roos; J H Neethling

    2013-02-01

    Copper samples having varying microstructures were deformed at high strain rates using a split-Hopkinson pressure bar. Transmission electron microscopy results show deformation twins present in samples that were both annealed and strained, whereas samples that were annealed and left unstrained, as well as samples that were unannealed and strained, are devoid of these twins. These deformation twins occurred at deformation conditions less extreme than previously predicted.

  20. MDT Performance in a High Rate Background Environment

    CERN Document Server

    Aleksa, Martin; Hessey, N P; Riegler, W

    1998-01-01

    A Cs137 gamma source with different lead filters in the SPS beam-line X5 has been used to simulate the ATLAS background radiation. This note shows the impact of high background rates on the MDT efficiency and resolution for three kinds of pulse shaping and compares the results with GARFIELD simulations. Furthermore it explains how the performance can be improved by time slewing corrections and double track separation.

  1. Mechanical properties of transgenic silkworm silk at high rate impact

    Science.gov (United States)

    Chu, Jou-Mei

    Transgenic silkworm silk was created to obtain the quality of spider silk while being mass-producible. Due to the variability in sequencing between the silkworm and spider DNA, the resulting transgenic silkworm silk may have different properties compared to spider silk. Furthermore, the high strain rate mechanical response of this new natural fiber is still unknown and needs to be characterized. In this experimental research, a quasi-static load frame (MTS) and a Kolsky tension bar are used to characterize the tensile stress-strain response of transgenic silkworm silk over a range of strain-rates between 10-3/s to 103/s. The results show that transgenic silkworm silk tends to have high overall elongation and initial stiffness at high strain rates compared to those of spider silk. Furthermore, specimen gage length sensitivity is studied with gage lengths of 3.97 mm (5/32 in), 4.76 mm (3/16 in), and 6.35 mm (1/4 in). Fracture surfaces are examined via Scanning Electron Microscopy (SEM) and reveal that the fracture mode is similar to that of spider silk. Therefore, it may be possible for the tensile properties of transgenic silkworm silk be comparable to that of spider silk.

  2. Semi-solid electrodes having high rate capability

    Science.gov (United States)

    Chiang, Yet-Ming; Duduta, Mihai; Holman, Richard; Limthongkul, Pimpa; Tan, Taison

    2016-06-07

    Embodiments described herein relate generally to electrochemical cells having high rate capability, and more particularly to devices, systems and methods of producing high capacity and high rate capability batteries having relatively thick semi-solid electrodes. In some embodiments, an electrochemical cell includes an anode and a semi-solid cathode. The semi-solid cathode includes a suspension of an active material of about 35% to about 75% by volume of an active material and about 0.5% to about 8% by volume of a conductive material in a non-aqueous liquid electrolyte. An ion-permeable membrane is disposed between the anode and the semi-solid cathode. The semi-solid cathode has a thickness of about 250 .mu.m to about 2,000 .mu.m, and the electrochemical cell has an area specific capacity of at least about 7 mAh/cm.sup.2 at a C-rate of C/4. In some embodiments, the semi-solid cathode slurry has a mixing index of at least about 0.9.

  3. Atomistic simulations of high strain rate loading of nanocrystals

    Science.gov (United States)

    Bringa, E. M.; Tramontina, D.; Ruestes, C. J.; Tang, Y.; Meyers, M. A.; Gunkelmann, N.; Urbassek, H. M.

    2013-03-01

    Materials loaded at high strain rates can reach extreme temperature and pressure conditions. Most experiments on loading of simple materials use poly crystals, while most atomistic simulations of shock wave loading deal with single crystals, due to the higher computational cost of running polycrystal samples. Of course, atomistic simulations of polycrystals with micron-sized grains are beyond the capabilities of current supercomputers. On the other hand, nanocrystals (nc) with grain sizes below 50 nm can be obtained experimentally and modeled reasonably well at high strain rates, opening the possibility of nearly direct comparison between atomistic molecular dynamics (MD) simulations and experiments using high power lasers. We will discuss MD simulations and links to experiments for nc Cu and Ni, as model f.c.c. solids, and nc Ta and Fe, as model b.c.c. solids. In all cases, the microstructure resulting from loading depends strongly on grain size, strain rate and peak applied pressure. We will also discuss effects related to target porosity in nc's. E.M.B. thanks funding from PICT2008-1325.

  4. High-rate electrochemical energy storage through Li+ intercalation pseudocapacitance.

    Science.gov (United States)

    Augustyn, Veronica; Come, Jérémy; Lowe, Michael A; Kim, Jong Woung; Taberna, Pierre-Louis; Tolbert, Sarah H; Abruña, Héctor D; Simon, Patrice; Dunn, Bruce

    2013-06-01

    Pseudocapacitance is commonly associated with surface or near-surface reversible redox reactions, as observed with RuO2·xH2O in an acidic electrolyte. However, we recently demonstrated that a pseudocapacitive mechanism occurs when lithium ions are inserted into mesoporous and nanocrystal films of orthorhombic Nb2O5 (T-Nb2O5; refs 1,2). Here, we quantify the kinetics of charge storage in T-Nb2O5: currents that vary inversely with time, charge-storage capacity that is mostly independent of rate, and redox peaks that exhibit small voltage offsets even at high rates. We also define the structural characteristics necessary for this process, termed intercalation pseudocapacitance, which are a crystalline network that offers two-dimensional transport pathways and little structural change on intercalation. The principal benefit realized from intercalation pseudocapacitance is that high levels of charge storage are achieved within short periods of time because there are no limitations from solid-state diffusion. Thick electrodes (up to 40 μm thick) prepared with T-Nb2O5 offer the promise of exploiting intercalation pseudocapacitance to obtain high-rate charge-storage devices.

  5. High Strain Rate Compression Testing of Ceramics and Ceramic Composites.

    Energy Technology Data Exchange (ETDEWEB)

    Blumenthal, W. R. (William R.)

    2005-01-01

    The compressive deformation and failure behavior of ceramics and ceramic-metal composites for armor applications has been studied as a function of strain rate at Los Alamos National Laboratory since the late 1980s. High strain rate ({approx}10{sup 3} s{sup -1}) uniaxial compression loading can be achieved using the Kolsky-split-Hopkinson pressure bar (SHPB) technique, but special methods must be used to obtain valid strength results. This paper reviews these methods and the limitations of the Kolsky-SHPB technique for this class of materials. The Kolsky-split-Hopkinson pressure bar (Kolsky-SHPB) technique was originally developed to characterize the mechanical behavior of ductile materials such as metals and polymers where the results can be used to develop strain-rate and temperature-dependent constitutive behavior models that empirically describe macroscopic plastic flow. The flow behavior of metals and polymers is generally controlled by thermally-activated and rate-dependent dislocation motion or polymer chain motion in response to shear stresses. Conversely, the macroscopic mechanical behavior of dense, brittle, ceramic-based materials is dominated by elastic deformation terminated by rapid failure associated with the propagation of defects in the material in response to resolved tensile stresses. This behavior is usually characterized by a distribution of macroscopically measured failure strengths and strains. The basis for any strain-rate dependence observed in the failure strength must originate from rate-dependence in the damage and fracture process, since uniform, uniaxial elastic behavior is rate-independent (e.g. inertial effects on crack growth). The study of microscopic damage and fracture processes and their rate-dependence under dynamic loading conditions is a difficult experimental challenge that is not addressed in this paper. The purpose of this paper is to review the methods that have been developed at the Los Alamos National Laboratory to

  6. Low-dose benznidazole treatment results in parasite clearance and attenuates heart inflammatory reaction in an experimental model of infection with a highly virulent Trypanosoma cruzi strain

    Directory of Open Access Journals (Sweden)

    Ágata Carolina Cevey

    2016-04-01

    Full Text Available Chagas disease, caused by Trypanosoma cruzi, is the main cause of dilated cardiomyopathy in the Americas. Antiparasitic treatment mostly relies on benznidazole (Bzl due to Nifurtimox shortage or unavailability. Both induce adverse drug effects (ADE of varied severity in many patients, leading to treatment discontinuation or abandonment. Since dosage may influence ADE, we aimed to assess Bzl efficacy in terms of parasiticidal and anti-inflammatory activity, using doses lower than those previously reported. BALB/c mice infected with the T. cruzi RA strain were treated with different doses of Bzl. Parasitaemia, mortality and weight change were assessed. Parasite load, tissue infiltrates and inflammatory mediators were studied in the heart. Serum creatine kinase (CK activity was determined as a marker of heart damage. The infection-independent anti-inflammatory properties of Bzl were studied in an in vitro model of LPS-treated cardiomyocyte culture. Treatment with 25 mg/kg/day Bzl turned negative the parasitological parameters, induced a significant decrease in IL-1β, IL-6 and NOS2 in the heart and CK activity in serum, to normal levels. No mortality was observed in infected treated mice. Primary cultured cardiomyocytes treated with Bzl showed that inflammatory mediators were reduced via inhibition of the NF-κB pathway. A Bzl dose lower than that previously reported for treatment of experimental Chagas disease exerts adequate antiparasitic and anti-inflammatory effects leading to parasite clearance and tissue healing. This may be relevant to reassess the dose currently used for the treatment of human Chagas disease, aiming to minimize ADE.

  7. Low-dose benznidazole treatment results in parasite clearance and attenuates heart inflammatory reaction in an experimental model of infection with a highly virulent Trypanosoma cruzi strain.

    Science.gov (United States)

    Cevey, Ágata Carolina; Mirkin, Gerardo Ariel; Penas, Federico Nicolás; Goren, Nora Beatriz

    2016-04-01

    Chagas disease, caused by Trypanosoma cruzi, is the main cause of dilated cardiomyopathy in the Americas. Antiparasitic treatment mostly relies on benznidazole (Bzl) due to Nifurtimox shortage or unavailability. Both induce adverse drug effects (ADE) of varied severity in many patients, leading to treatment discontinuation or abandonment. Since dosage may influence ADE, we aimed to assess Bzl efficacy in terms of parasiticidal and anti-inflammatory activity, using doses lower than those previously reported. BALB/c mice infected with the T. cruzi RA strain were treated with different doses of Bzl. Parasitaemia, mortality and weight change were assessed. Parasite load, tissue infiltrates and inflammatory mediators were studied in the heart. Serum creatine kinase (CK) activity was determined as a marker of heart damage. The infection-independent anti-inflammatory properties of Bzl were studied in an in vitro model of LPS-treated cardiomyocyte culture. Treatment with 25 mg/kg/day Bzl turned negative the parasitological parameters, induced a significant decrease in IL-1β, IL-6 and NOS2 in the heart and CK activity in serum, to normal levels. No mortality was observed in infected treated mice. Primary cultured cardiomyocytes treated with Bzl showed that inflammatory mediators were reduced via inhibition of the NF-κB pathway. A Bzl dose lower than that previously reported for treatment of experimental Chagas disease exerts adequate antiparasitic and anti-inflammatory effects leading to parasite clearance and tissue healing. This may be relevant to reassess the dose currently used for the treatment of human Chagas disease, aiming to minimize ADE.

  8. Scale dependence of rock friction at high work rate.

    Science.gov (United States)

    Yamashita, Futoshi; Fukuyama, Eiichi; Mizoguchi, Kazuo; Takizawa, Shigeru; Xu, Shiqing; Kawakata, Hironori

    2015-12-10

    Determination of the frictional properties of rocks is crucial for an understanding of earthquake mechanics, because most earthquakes are caused by frictional sliding along faults. Prior studies using rotary shear apparatus revealed a marked decrease in frictional strength, which can cause a large stress drop and strong shaking, with increasing slip rate and increasing work rate. (The mechanical work rate per unit area equals the product of the shear stress and the slip rate.) However, those important findings were obtained in experiments using rock specimens with dimensions of only several centimetres, which are much smaller than the dimensions of a natural fault (of the order of 1,000 metres). Here we use a large-scale biaxial friction apparatus with metre-sized rock specimens to investigate scale-dependent rock friction. The experiments show that rock friction in metre-sized rock specimens starts to decrease at a work rate that is one order of magnitude smaller than that in centimetre-sized rock specimens. Mechanical, visual and material observations suggest that slip-evolved stress heterogeneity on the fault accounts for the difference. On the basis of these observations, we propose that stress-concentrated areas exist in which frictional slip produces more wear materials (gouge) than in areas outside, resulting in further stress concentrations at these areas. Shear stress on the fault is primarily sustained by stress-concentrated areas that undergo a high work rate, so those areas should weaken rapidly and cause the macroscopic frictional strength to decrease abruptly. To verify this idea, we conducted numerical simulations assuming that local friction follows the frictional properties observed on centimetre-sized rock specimens. The simulations reproduced the macroscopic frictional properties observed on the metre-sized rock specimens. Given that localized stress concentrations commonly occur naturally, our results suggest that a natural fault may lose its

  9. Re-entry flight clearance

    NARCIS (Netherlands)

    Juliana, S.

    2006-01-01

    The objective of the research was to identify and evaluate promising mathematical techniques for re-entry flight clearance. To fulfil this objective, two mathematical methods were investigated and developed: μ analysis for linear models and interval analysis for both linear and non-linear model

  10. Brachytherapy for early oral tongue cancer. Low dose rate to high dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Hideya [Toyonaka Municipal Hospital, Osaka (Japan); Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Inoue, Toshihiko [Osaka Univ., Suita (Japan). Graduate School of Medicine; Furukawa, Souhei; Kakimoto, Naoya [Osaka Univ., Suita (Japan). Graduate School of Dentistry

    2003-03-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n=341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer. (author)

  11. Brachytherapy for early oral tongue cancer: low dose rate to high dose rate.

    Science.gov (United States)

    Yamazaki, Hideya; Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Furukawa, Souhei; Kakimoto, Naoya; Shimizutani, Kimishige; Inoue, Toshihiko

    2003-03-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n = 341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer.

  12. A spark-protected high-rate detector

    CERN Document Server

    Fonte, Paulo J R; Costa, L; Ferreira-Marques, R; Mendiratta, S; Peskov, Vladimir; Policarpo, Armando

    1999-01-01

    We developed a very low resistivity RPC-type detector, the anode of which was a plate made from materials with resistivity up to 5x10 sup 7 OMEGA cm, the cathode being a metallic mesh preceded by a drift region. In such a detector it was actually possible to combine the versatility and high counting-rate capability of metallic PPACs with the extreme robustness and 'protectiveness' of Resistive Plate Chambers. Occasional discharges triggered by large deposits of primary ionisation or by extreme counting rates are quenched by the resistive anode and are constrained to the streamer phase of the sparking process. The study shows that this discharge affects the detector only locally and that the charge released is limited to a few tens of nC. Proportional counting rates up to 10 sup 5 Hz/mm sup 2 were achieved at gains above 10 sup 4. The energy resolution at 6 keV was 20% FWHM. The observed gain-rate trade-off is well described by an analytic model and further improvements may be expected by lowering the resistiv...

  13. A spark-protected high-rate detector

    Energy Technology Data Exchange (ETDEWEB)

    Fonte, P. E-mail: paulo.fonte@cern.chfonte@lipc.fis.uc.pt; Carolino, N.; Costa, L.; Ferreira-Marques, Rui; Mendiratta, S.; Peskov, V.; Policarpo, A

    1999-07-11

    We developed a very low resistivity RPC-type detector, the anode of which was a plate made from materials with resistivity up to 5x10{sup 7} {omega} cm, the cathode being a metallic mesh preceded by a drift region. In such a detector it was actually possible to combine the versatility and high counting-rate capability of metallic PPACs with the extreme robustness and 'protectiveness' of Resistive Plate Chambers. Occasional discharges triggered by large deposits of primary ionisation or by extreme counting rates are quenched by the resistive anode and are constrained to the streamer phase of the sparking process. The study shows that this discharge affects the detector only locally and that the charge released is limited to a few tens of nC. Proportional counting rates up to 10{sup 5} Hz/mm{sup 2} were achieved at gains above 10{sup 4}. The energy resolution at 6 keV was 20% FWHM. The observed gain-rate trade-off is well described by an analytic model and further improvements may be expected by lowering the resistivity of the anode material. The properties of several custom-made, controllable resistivity, anode materials are described and prospects of improvement in the performance of the detector are discussed. (author)

  14. High monetary reward rates and caloric rewards decrease temporal persistence

    Science.gov (United States)

    Bode, Stefan; Murawski, Carsten

    2017-01-01

    Temporal persistence refers to an individual's capacity to wait for future rewards, while forgoing possible alternatives. This requires a trade-off between the potential value of delayed rewards and opportunity costs, and is relevant to many real-world decisions, such as dieting. Theoretical models have previously suggested that high monetary reward rates, or positive energy balance, may result in decreased temporal persistence. In our study, 50 fasted participants engaged in a temporal persistence task, incentivised with monetary rewards. In alternating blocks of this task, rewards were delivered at delays drawn randomly from distributions with either a lower or higher maximum reward rate. During some blocks participants received either a caloric drink or water. We used survival analysis to estimate participants' probability of quitting conditional on the delay distribution and the consumed liquid. Participants had a higher probability of quitting in blocks with the higher reward rate. Furthermore, participants who consumed the caloric drink had a higher probability of quitting than those who consumed water. Our results support the predictions from the theoretical models, and importantly, suggest that both higher monetary reward rates and physiologically relevant rewards can decrease temporal persistence, which is a crucial determinant for survival in many species. PMID:28228517

  15. Lithium manganese spinel materials for high-rate electrochemical applications

    Institute of Scientific and Technical Information of China (English)

    Anna V. Potapenko; Sviatoslav A. Kirillov

    2014-01-01

    In order to successively compete with supercapacitors, an ability of fast discharge is a must for lithium-ion batteries. From this point of view, stoichiometric and substituted lithium manganese spinels as cathode materials are one of the most prospective candidates, especially in their nanosized form. In this article, an overview of the most recent data regarding physico-chemical and electrochemical properties of lithium manganese spinels, especially, LiMn2O4 and LiNi0.5Mn1.5O4, synthesized by means of various methods is presented, with special emphasis of their use in high-rate electrochemical applications. In particular, specific capacities and rate capabilities of spinel materials are analyzed. It is suggested that reduced specific capacity is determined primarily by the aggregation of material particles, whereas good high-rate capability is governed not only by the size of crystallites but also by the perfectness of crystals. The most technologically advantageous solutions are described, existing gaps in the knowledge of spinel materials are outlined, and the ways of their filling are suggested, in a hope to be helpful in keeping lithium batteries afloat in the struggle for a worthy place among electrochemical energy systems of the 21st century.

  16. High mortality rates after non-elective colon cancer resection

    DEFF Research Database (Denmark)

    Bakker, I S; Snijders, H S; Grossmann, Irene

    2016-01-01

    AIM: Colon cancer resection in a non-elective setting is associated with high rates of morbidity and mortality. The aim of this retrospective study is to identify risk factors for overall mortality after colon cancer resection with a special focus on non-elective resection. METHOD: Data were...... obtained from the Dutch Surgical Colorectal Audit. Patients undergoing colon cancer resection in the Netherlands between January 2009 and December 2013 were included. Patient, treatment and tumour factors were analyzed in relation to the urgency of surgery. The primary outcome was the thirty day...... postoperative mortality. RESULTS: The study included 30,907 patients. In 5934 (19.2%) of patients, a non-elective colon cancer resection was performed. There was a 4.4% overall mortality rate, with significantly more deaths after non-elective surgery (8.5% vs 3.4%, P

  17. Atrial high-rate episodes and stroke prevention

    DEFF Research Database (Denmark)

    Camm, A John; Simantirakis, Emmanuel; Goette, Andreas;

    2016-01-01

    While the benefit of oral anticoagulants (OACs) for stroke prevention in patients with atrial fibrillation (AF) is well established, it is not known whether oral anticoagulation is indicated in patients with atrial high-rate episodes (AHRE) recorded on a cardiac implantable electronic device......, sometimes also called subclinical AF, and lasting for at least 6 min in the absence of clinically diagnosed AF. Clinical evidence has shown that short episodes of rapid atrial tachycarrhythmias are often detected in patients presenting with stroke and transient ischaemic attack. Patients with AHRE have...... a higher likelihood of suffering from subsequent strokes, but their stroke rate seems lower than in patients with diagnosed AF, and not all AHRE episodes correspond to AF. The prognostic and pathological significance of AHRE is not yet fully understood. Clinical trials of OAC therapy are being conducted...

  18. Fast demographic traits promote high diversification rates of Amazonian trees

    Science.gov (United States)

    Baker, Timothy R; Pennington, R Toby; Magallon, Susana; Gloor, Emanuel; Laurance, William F; Alexiades, Miguel; Alvarez, Esteban; Araujo, Alejandro; Arets, Eric J M M; Aymard, Gerardo; de Oliveira, Atila Alves; Amaral, Iêda; Arroyo, Luzmila; Bonal, Damien; Brienen, Roel J W; Chave, Jerome; Dexter, Kyle G; Di Fiore, Anthony; Eler, Eduardo; Feldpausch, Ted R; Ferreira, Leandro; Lopez-Gonzalez, Gabriela; van der Heijden, Geertje; Higuchi, Niro; Honorio, Eurídice; Huamantupa, Isau; Killeen, Tim J; Laurance, Susan; Leaño, Claudio; Lewis, Simon L; Malhi, Yadvinder; Marimon, Beatriz Schwantes; Marimon Junior, Ben Hur; Monteagudo Mendoza, Abel; Neill, David; Peñuela-Mora, Maria Cristina; Pitman, Nigel; Prieto, Adriana; Quesada, Carlos A; Ramírez, Fredy; Ramírez Angulo, Hirma; Rudas, Agustin; Ruschel, Ademir R; Salomão, Rafael P; de Andrade, Ana Segalin; Silva, J Natalino M; Silveira, Marcos; Simon, Marcelo F; Spironello, Wilson; ter Steege, Hans; Terborgh, John; Toledo, Marisol; Torres-Lezama, Armando; Vasquez, Rodolfo; Vieira, Ima Célia Guimarães; Vilanova, Emilio; Vos, Vincent A; Phillips, Oliver L; Wiens, John

    2014-01-01

    The Amazon rain forest sustains the world's highest tree diversity, but it remains unclear why some clades of trees are hyperdiverse, whereas others are not. Using dated phylogenies, estimates of current species richness and trait and demographic data from a large network of forest plots, we show that fast demographic traits – short turnover times – are associated with high diversification rates across 51 clades of canopy trees. This relationship is robust to assuming that diversification rates are either constant or decline over time, and occurs in a wide range of Neotropical tree lineages. This finding reveals the crucial role of intrinsic, ecological variation among clades for understanding the origin of the remarkable diversity of Amazonian trees and forests. PMID:24589190

  19. An Architecture for High Data Rate Very Low Frequency Communication

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2013-01-01

    Full Text Available Very low frequency (VLF communication is used for long range shore-to-ship broadcasting applications. This paper proposes an architecture for high data rate VLF communication using Gaussian minimum shift keying (GMSK modulation and low delay parity check (LDPC channel coding. Non-data aided techniques are designed and used for carrier phase synchronization, symbol timing recovery, and LDPC code frame synchronization. These require the estimation of the operative Eb/N0 for which a kurtosis based algorithm is used. Also, a method for modeling the probability density function of the received signal under the bit condition is presented in this regard. The modeling of atmospheric radio noise (ARN that corrupts VLF signals is described and an algorithm for signal enhancement in the presence of ARN in given. The BER performance of the communication system is evaluated for bit rates of 400 bps, 600 bps, and 800 bps for communication bandwidth of ~200 Hz.

  20. Experimental investigation of bond strength under high loading rates

    Science.gov (United States)

    Michal, Mathias; Keuser, Manfred; Solomos, George; Peroni, Marco; Larcher, Martin; Esteban, Beatriz

    2015-09-01

    The structural behaviour of reinforced concrete is governed significantly by the transmission of forces between steel and concrete. The bond is of special importance for the overlapping joint and anchoring of the reinforcement, where rigid bond is required. It also plays an important role in the rotational capacity of plastic hinges, where a ductile bond behaviour is preferable. Similar to the mechanical properties of concrete and steel also the characteristics of their interaction changes with the velocity of the applied loading. For smooth steel bars with its main bond mechanisms of adhesion and friction, nearly no influence of loading rate is reported in literature. In contrast, a high rate dependence can be found for the nowadays mainly used deformed bars. For mechanical interlock, where ribs of the reinforcing steel are bracing concrete material surrounding the bar, one reason can be assumed to be in direct connection with the increase of concrete compressive strength. For splitting failure of bond, characterized by the concrete tensile strength, an even higher dynamic increase is observed. For the design of Structures exposed to blast or impact loading the knowledge of a rate dependent bond stress-slip relationship is required to consider safety and economical aspects at the same time. The bond behaviour of reinforced concrete has been investigated with different experimental methods at the University of the Bundeswehr Munich (UniBw) and the Joint Research Centre (JRC) in Ispra. Both static and dynamic tests have been carried out, where innovative experimental apparatuses have been used. The bond stress-slip relationship and maximum pull-out-forces for varying diameter of the bar, concrete compressive strength and loading rates have been obtained. It is expected that these experimental results will contribute to a better understanding of the rate dependent bond behaviour and will serve for calibration of numerical models.

  1. Experimental investigation of bond strength under high loading rates

    Directory of Open Access Journals (Sweden)

    Michal Mathias

    2015-01-01

    Full Text Available The structural behaviour of reinforced concrete is governed significantly by the transmission of forces between steel and concrete. The bond is of special importance for the overlapping joint and anchoring of the reinforcement, where rigid bond is required. It also plays an important role in the rotational capacity of plastic hinges, where a ductile bond behaviour is preferable. Similar to the mechanical properties of concrete and steel also the characteristics of their interaction changes with the velocity of the applied loading. For smooth steel bars with its main bond mechanisms of adhesion and friction, nearly no influence of loading rate is reported in literature. In contrast, a high rate dependence can be found for the nowadays mainly used deformed bars. For mechanical interlock, where ribs of the reinforcing steel are bracing concrete material surrounding the bar, one reason can be assumed to be in direct connection with the increase of concrete compressive strength. For splitting failure of bond, characterized by the concrete tensile strength, an even higher dynamic increase is observed. For the design of Structures exposed to blast or impact loading the knowledge of a rate dependent bond stress-slip relationship is required to consider safety and economical aspects at the same time. The bond behaviour of reinforced concrete has been investigated with different experimental methods at the University of the Bundeswehr Munich (UniBw and the Joint Research Centre (JRC in Ispra. Both static and dynamic tests have been carried out, where innovative experimental apparatuses have been used. The bond stress-slip relationship and maximum pull-out-forces for varying diameter of the bar, concrete compressive strength and loading rates have been obtained. It is expected that these experimental results will contribute to a better understanding of the rate dependent bond behaviour and will serve for calibration of numerical models.

  2. Precise muon drift tube detectors for high background rate conditions

    CERN Document Server

    Engl, Albert; Dünnweber, Wolfgang

    The muon spectrometer of the ATLAS-experiment at the Large H adron Collider consists of drift tube chambers, which provide the precise m easurement of trajec- tories of traversing muons. In order to determine the moment um of the muons with high precision, the measurement of the position of the m uon in a single tube has to be more accurate than σ ≤ 100 m. The large cross section of proton-proton-collisions and th e high luminosity of the accelerator cause relevant background of neutrons and γ s in the muon spectrome- ter. During the next decade a luminosity upgrade [1] to 5 10 34 cm − 2 s − 1 is planned, which will increase the background counting rates consider ably. In this context this work deals with the further development of the existing drift chamber tech- nology to provide the required accuracy of the position meas urement under high background conditions. Two approaches of improving the dri ft tube chambers are described: • In regions of moderate background rates a faster and more lin ear ...

  3. Handling high data rate detectors at Diamond Light Source

    Science.gov (United States)

    Pedersen, U. K.; Rees, N.; Basham, M.; Ferner, F. J. K.

    2013-03-01

    An increasing number of area detectors, in use at Diamond Light Source, produce high rates of data. In order to capture, store and process this data High Performance Computing (HPC) systems have been implemented. This paper will present the architecture and usage for handling high rate data: detector data capture, large volume storage and parallel processing. The EPICS area Detector frame work has been adopted to abstract the detectors for common tasks including live processing, file format and storage. The chosen data format is HDF5 which provides multidimensional data storage and NeXuS compatibility. The storage system and related computing infrastructure include: a centralised Lustre based parallel file system, a dedicated network and a HPC cluster. A well defined roadmap is in place for the evolution of this to meet demand as the requirements and technology advances. For processing the science data the HPC cluster allow efficient parallel computing, on a mixture of ×86 and GPU processing units. The nature of the Lustre storage system in combination with the parallel HDF5 library allow efficient disk I/O during computation jobs. Software developments, which include utilising optimised parallel file reading for a variety of post processing techniques, are being developed in collaboration as part of the Pan-Data EU Project (www.pan-data.eu). These are particularly applicable to tomographic reconstruction and processing of non crystalline diffraction data.

  4. Measurement of fracture properties of concrete at high strain rates

    Science.gov (United States)

    Rey-De-Pedraza, V.; Cendón, D. A.; Sánchez-Gálvez, V.; Gálvez, F.

    2017-01-01

    An analysis of the spalling technique of concrete bars using the modified Hopkinson bar was carried out. A new experimental configuration is proposed adding some variations to previous works. An increased length for concrete specimens was chosen and finite-element analysis was used for designing a conic projectile to obtain a suitable triangular impulse wave. The aim of this initial work is to establish an experimental framework which allows a simple and direct analysis of concrete subjected to high strain rates. The efforts and configuration of these primary tests, as well as the selected geometry and dimensions for the different elements, have been focused to achieve a simple way of identifying the fracture position and so the tensile strength of tested specimens. This dynamic tensile strength can be easily compared with previous values published in literature giving an idea of the accuracy of the method and technique proposed and the possibility to extend it in a near future to obtain other mechanical properties such as the fracture energy. The tests were instrumented with strain gauges, accelerometers and high-speed camera in order to validate the results by different ways. Results of the dynamic tensile strength of the tested concrete are presented. This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'.

  5. Measurement of fracture properties of concrete at high strain rates.

    Science.gov (United States)

    Rey-De-Pedraza, V; Cendón, D A; Sánchez-Gálvez, V; Gálvez, F

    2017-01-28

    An analysis of the spalling technique of concrete bars using the modified Hopkinson bar was carried out. A new experimental configuration is proposed adding some variations to previous works. An increased length for concrete specimens was chosen and finite-element analysis was used for designing a conic projectile to obtain a suitable triangular impulse wave. The aim of this initial work is to establish an experimental framework which allows a simple and direct analysis of concrete subjected to high strain rates. The efforts and configuration of these primary tests, as well as the selected geometry and dimensions for the different elements, have been focused to achieve a simple way of identifying the fracture position and so the tensile strength of tested specimens. This dynamic tensile strength can be easily compared with previous values published in literature giving an idea of the accuracy of the method and technique proposed and the possibility to extend it in a near future to obtain other mechanical properties such as the fracture energy. The tests were instrumented with strain gauges, accelerometers and high-speed camera in order to validate the results by different ways. Results of the dynamic tensile strength of the tested concrete are presented.This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'.

  6. High Rate Laser Pitting Technique for Solar Cell Texturing

    Energy Technology Data Exchange (ETDEWEB)

    Hans J. Herfurth; Henrikki Pantsar

    2013-01-10

    High rate laser pitting technique for solar cell texturing Efficiency of crystalline silicon solar cells can be improved by creating a texture on the surface to increase optical absorption. Different techniques have been developed for texturing, with the current state-of-the-art (SOA) being wet chemical etching. The process has poor optical performance, produces surfaces that are difficult to passivate or contact and is relatively expensive due to the use of hazardous chemicals. This project shall develop an alternative process for texturing mc-Si using laser micromachining. It will have the following features compared to the current SOA texturing process: -Superior optical surfaces for reduced front-surface reflection and enhanced optical absorption in thin mc-Si substrates -Improved surface passivation -More easily integrated into advanced back-contact cell concepts -Reduced use of hazardous chemicals and waste treatment -Similar or lower cost The process is based on laser pitting. The objective is to develop and demonstrate a high rate laser pitting process which will exceed the rate of former laser texturing processes by a factor of ten. The laser and scanning technologies will be demonstrated on a laboratory scale, but will use inherently technologies that can easily be scaled to production rates. The drastic increase in process velocity is required for the process to be implemented as an in-line process in PV manufacturing. The project includes laser process development, development of advanced optical systems for beam manipulation and cell reflectivity and efficiency testing. An improvement of over 0.5% absolute in efficiency is anticipated after laser-based texturing. The surface textures will be characterized optically, and solar cells will be fabricated with the new laser texturing to ensure that the new process is compatible with high-efficiency cell processing. The result will be demonstration of a prototype process that is suitable for scale-up to a

  7. High-Strain Rate Testing of Gun Propellants

    Science.gov (United States)

    1988-12-01

    formulations under high loading rates have been studied previously (see Fong (1985); et al. (1981); Schubert and Schmitt (1973); Greidanus (1976...the transmission of a wave was described by Davies and Hunter (1963) and by Hoge (1970). Impedance is defined as Z = A(pE)h, where A is the area, p is...A = ma, a2u ac a 2U m = p A dx, a = . Assembling these, - p -= at 2 ax at 2 For isotropic elastic materials, a = Ee, where e = au/ax. The partial

  8. Design of high-bit-rate coherent communication links

    Science.gov (United States)

    Konyshev, V. A.; Leonov, A. V.; Nanii, O. E.; Novikov, A. G.; Treshchikov, V. N.; Ubaydullaev, R. R.

    2016-12-01

    We report an analysis of the problems encountered in the design of modern high-bit-rate coherent communication links. A phenomenological communication link model is described, which is suitable for solving applied tasks of the network design with nonlinear effects taken into account. We propose an engineering approach to the design that is based on the use of fundamental nonlinearity coefficients calculated in advance for the experimental configurations of communication links. An experimental method is presented for calculating the nonlinearity coefficient of communication links. It is shown that the proposed approach allows one to successfully meet the challenges in designing communication networks.

  9. Factors affecting high resting pulse rate in military pilots

    Directory of Open Access Journals (Sweden)

    Minarma Siagian

    2014-02-01

    Aviation and Aerospace (LAKESPRA from 2003 to 2008. The data extracted from medical records were age, rank, total flight hours, average yearly flight hours, and type of aircraft. Results: Out of 539 pilots, there were 155 with high resting pulse rate. Compared to pilots aged 23-29 years, pilots aged 30-39 years had 66% more risk for high resting pulse rate [adjusted odds ratio (ORa = 1.66; 95% confidence interval (CI = 1.17-2.35, P = 0.004], and those aged 40-49 years had a 2.4 risk (ORa = 2.40; P = 0.000]. Compared to pilots of transport planes, jet fighter pilots had a 59% more risk for high resting pulse rate (ORa = 1.59; P = 0.002. Conclusion: Older  age  and  fighter  jets  increased  the  risk  of  high  resting  pulse  rate  in  pilots. (Health Science Indones 2013;2:51-4Key words: age, type of aircraft, resting pulse rate, pilots

  10. Radiation Hardened, Modulator ASIC for High Data Rate Communications

    Science.gov (United States)

    McCallister, Ron; Putnam, Robert; Andro, Monty; Fujikawa, Gene

    2000-01-01

    Satellite-based telecommunication services are challenged by the need to generate down-link power levels adequate to support high quality (BER approx. equals 10(exp 12)) links required for modem broadband data services. Bandwidth-efficient Nyquist signaling, using low values of excess bandwidth (alpha), can exhibit large peak-to-average-power ratio (PAPR) values. High PAPR values necessitate high-power amplifier (HPA) backoff greater than the PAPR, resulting in unacceptably low HPA efficiency. Given the high cost of on-board prime power, this inefficiency represents both an economical burden, and a constraint on the rates and quality of data services supportable from satellite platforms. Constant-envelope signals offer improved power-efficiency, but only by imposing a severe bandwidth-efficiency penalty. This paper describes a radiation- hardened modulator which can improve satellite-based broadband data services by combining the bandwidth-efficiency of low-alpha Nyquist signals with high power-efficiency (negligible HPA backoff).

  11. Clearance of high-risk human papillomavirus after treatment for high-grade squamous intraepithelial lesions%宫颈高度鳞状上皮内病变治疗后高危型人乳头瘤病毒的消退规律

    Institute of Scientific and Technical Information of China (English)

    陈观娣; 钱德英; 岑坚敏; 舒焰红; 欧阳云雁; 郑有为

    2011-01-01

    Objective To investigate the rate of clearance of high-risk human papillomavirus (HPV) infection after loop electrosurgical excision procedure(LEEP) for high-grade squamous intraepithelial lesions, and to study the relation between high-risk HPV persistent infection and residual/recurrent disease after LEEP.Methods A retrospective study was conducted on 502 women who underwent LEEP for high-grade squamous intraepithelial lesions between January 2003 and December 2007 in the Guangdong General Hospital.Results Among those who were high-risk HPV infected before LEEP, the clearance rate of high-risk HPV was 83.63%, 94.39%, 97.31% ,and 98.88% after treatment 6 months, 12 months, 18 months and 24 months, respectively.Of women with high-risk HPV persistent infection after LEEP, 26.85% developed residual/recurrent disease.Conclusion LEEP is an important treatment for high-grade squamous intraepithelial lesions,and it is a highly effective method of eradicating HPV.HPV-DNA testing is a useful means for monitoring the efficacy of treatments during follow-up.We suggest the initial testing should perform at 6 months for the follow-up.%目的 探讨宫颈高度鳞状上皮内病变治疗后高危型人乳头瘤病毒(HPV)的消退规律,了解术后高危型HPV持续感染与病变残留或复发之间的关系.方法 对2003年1月至2007年12月在广东省人民医院因宫颈高度鳞状上皮内病变行宫颈电环切除术的502例妇女的随访资料进行回顾性分析.结果 术前存在高危型HPV感染的宫颈高度鳞状上皮内病变进行宫颈电环切除术治疗后,术后6、12、18、24个月HPV清除率分别为83.63%、94.39%、97.31%、98.88%.术后高危型HPV持续感染人群病变残留或复发率达26.85%.结论 宫颈电环切除术后6个月高危型HPV己大部分消退,术后2年基本完全消退.术后宫危型HPV持续感染是病变残留或复发的高危因素,术后HPV阳性妇女,宜严密随访.

  12. High-rate lithium thionyl-chloride battery development

    Energy Technology Data Exchange (ETDEWEB)

    Cieslak, W.R.; Weigand, D.E.

    1993-12-31

    We have developed a lithium thionyl-chloride cell for use in a high rate battery application to provide power for a missile computer and stage separation detonators. The battery pack contains 20 high surface area ``DD`` cells wired in a series-parallel configuration to supply a nominal 28 volts with a continuous draw of 20 amperes. The load profile also requires six squib firing pulses of one second duration at a 20 ampere peak. Performance and safety of the cells were optimized in a ``D`` cell configuration before progressing to the longer ``DD` cell. Active surface area in the ``D`` cell is 735 cm{sup 2}, and 1650 cm{sup 2} in the ``DD`` cell. The design includes 1.5M LiAlCl{sub 4}/SOCl{sub 2} electrolyte, a cathode blend of Shawinigan Acetylene Black and Cabot Black Pearls 2000 carbons, Scimat ETFE separator, and photoetched current collectors.

  13. New Approach to reduce High School Dropout Rates

    Directory of Open Access Journals (Sweden)

    Mauricio Cristhian Portillo-Torres

    2015-05-01

    Full Text Available From 2006 to 2014, the Ministry of Public Education of Costa Rica implemented four strategic actions to reduce high school dropout rates. The main purpose of these actions was to promote student participation and student identification with their school. Studies prepared by the Ministry of Education and the Comptroller of the Republic were revised to assess the impact of these actions. The result of these actions does not show an actual decrease in the number of students who leave high school. Therefore, a more holistic view is necessary to ensure the students’ stay. This review suggests using use the concept of student engagement and applying a three tier system-wide dropout preventive actions: universal, targeted and intensive.

  14. On the response of rubbers at high strain rates.

    Energy Technology Data Exchange (ETDEWEB)

    Niemczura, Johnathan Greenberg (University of Texas-Austin)

    2010-02-01

    In this report, we examine the propagation of tensile waves of finite deformation in rubbers through experiments and analysis. Attention is focused on the propagation of one-dimensional dispersive and shock waves in strips of latex and nitrile rubber. Tensile wave propagation experiments were conducted at high strain-rates by holding one end fixed and displacing the other end at a constant velocity. A high-speed video camera was used to monitor the motion and to determine the evolution of strain and particle velocity in the rubber strips. Analysis of the response through the theory of finite waves and quantitative matching between the experimental observations and analytical predictions was used to determine an appropriate instantaneous elastic response for the rubbers. This analysis also yields the tensile shock adiabat for rubber. Dispersive waves as well as shock waves are also observed in free-retraction experiments; these are used to quantify hysteretic effects in rubber.

  15. Automated Production of High Rep Rate Foam Targets

    Science.gov (United States)

    Hall, F.; Spindloe, C.; Haddock, D.; Tolley, M.; Nazarov, W.

    2016-04-01

    Manufacturing low density targets in the numbers needed for high rep rate experiments is highly challenging. This report summarises advances from manual production to semiautomated and the improvements that follow both in terms of production time and target uniformity. The production process is described and shown to be improved by the integration of an xyz robot with dispensing capabilities. Results are obtained from manual and semiautomated production runs and compared. The variance in the foam thickness is reduced significantly which should decrease experimental variation due to target parameters and could allow for whole batches to be characterised by the measurement of a few samples. The work applies to both foil backed and free standing foam targets.

  16. Resistance of the boreal forest to high burn rates.

    Science.gov (United States)

    Héon, Jessie; Arseneault, Dominique; Parisien, Marc-André

    2014-09-23

    Boreal ecosystems and their large carbon stocks are strongly shaped by extensive wildfires. Coupling climate projections with records of area burned during the last 3 decades across the North American boreal zone suggests that area burned will increase by 30-500% by the end of the 21st century, with a cascading effect on ecosystem dynamics and on the boreal carbon balance. Fire size and the frequency of large-fire years are both expected to increase. However, how fire size and time since previous fire will influence future burn rates is poorly understood, mostly because of incomplete records of past fire overlaps. Here, we reconstruct the length of overlapping fires along a 190-km-long transect during the last 200 y in one of the most fire-prone boreal regions of North America to document how fire size and time since previous fire will influence future fire recurrence. We provide direct field evidence that extreme burn rates can be sustained by a few occasional droughts triggering immense fires. However, we also show that the most fire-prone areas of the North American boreal forest are resistant to high burn rates because of overabundant young forest stands, thereby creating a fuel-mediated negative feedback on fire activity. These findings will help refine projections of fire effect on boreal ecosystems and their large carbon stocks.

  17. High false positive rates in common sensory threshold tests.

    Science.gov (United States)

    Running, Cordelia A

    2015-02-01

    Large variability in thresholds to sensory stimuli is observed frequently even in healthy populations. Much of this variability is attributed to genetics and day-to-day fluctuation in sensitivity. However, false positives are also contributing to the variability seen in these tests. In this study, random number generation was used to simulate responses in threshold methods using different "stopping rules": ascending 2-alternative forced choice (AFC) with 5 correct responses; ascending 3-AFC with 3 or 4 correct responses; staircase 2-AFC with 1 incorrect up and 2 incorrect down, as well as 1 up 4 down and 5 or 7 reversals; staircase 3-AFC with 1 up 2 down and 5 or 7 reversals. Formulas are presented for rates of false positives in the ascending methods, and curves were generated for the staircase methods. Overall, the staircase methods generally had lower false positive rates, but these methods were influenced even more by number of presentations than ascending methods. Generally, the high rates of error in all these methods should encourage researchers to conduct multiple tests per individual and/or select a method that can correct for false positives, such as fitting a logistic curve to a range of responses.

  18. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  19. High rates of methane emissions from south taiga wetland ponds.

    Science.gov (United States)

    Glagolev, M.; Kleptsova, I.; Maksyutov, S.

    2012-04-01

    Since wetland ponds are often assumed to be insignificant sources of methane, there is a limited data about its fluxes. In this study, we found surprisingly high rates of methane emission at several shallow ponds in the south taiga zone of West Siberia. Wetland ponds within the Great Vasyugan Mire ridge-hollow-pool patterned bog system were investigated. 22 and 24 flux measurements from ponds and surrounded mires, respectively, were simultaneously made by a static chamber method in July, 2011. In contrast to previous measurements, fluxes were measured using the small boat with floated chamber to avoid disturbance to the water volume. Since the ebullition is most important emission pathway, minimization of physical disturbance provoking gas bubbling significantly increases the data accuracy. Air temperature varied from 15 to 22° C during the measurements, and pH at different pond depths - from 4.4 to 5. As it was found, background emission from surrounding ridges and hollows was 1.7/2.6/3.3 mgC·m-2·h1 (1st/2nd/3rd quartiles). These rates are in a perfect correspondence with the typical methane emission fluxes from other south taiga bogs. Methane emission from wetland ponds turned out to be by order of magnitude higher (9.3/11.3/15.6 mgC·m-2·h1). Comparing to other measurements in West Siberia, many times higher emissions (70.9/111.6/152.3 mgC·m-2·h1) were found in forest-steppe and subtaiga fen ponds. On the contrary, West Siberian tundra lakes emit methane insignificantly, with the flux rate close to surrounding wetlands (about 0.2-0.3 mgC·m-2·h1). Apparently, there is a naturally determined distribution of ponds with different flux rates over different West Siberia climate-vegetation zones. Further investigations aiming at revelation of the zones with different fluxes would be helpful for total flux revision purposes. With respect to other studies, high emission rates were already detected, for instance, in Baltic ponds (Dzyuban, 2002) and U.K. lakes

  20. Understanding of the Interaction between Clearance Leakage Flow and Main Passage Flow in a VGT Turbine

    Directory of Open Access Journals (Sweden)

    Ben Zhao

    2015-02-01

    Full Text Available The clearance flow between the nozzle and endwall in a variable geometry turbine (VGT has been numerically investigated to understand the clearance effect on the VGT performance and internal flow. It was found that the flow rate through turbine increases but the turbine efficiency decreases with height of clearance. Detailed flow field analyses indicated that most of the efficiency loss resulting from the leakage flow occurs at the upstream of the rotor area, that is, in the nozzle endwall clearance and between the nozzle vanes. There are two main mechanisms associated with this efficiency loss. One is due to the formation of the local vortex flow structure between the clearance flow and the main flow. The other is due to the impact of the clearance flow on the main flow after the nozzle throat. This impact reduces the span of shockwave with increased shockwave magnitude by changing the trajectory of the main flow.

  1. 49 CFR 192.325 - Underground clearance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Underground clearance. 192.325 Section 192.325... Lines and Mains § 192.325 Underground clearance. (a) Each transmission line must be installed with at least 12 inches (305 millimeters) of clearance from any other underground structure not associated with...

  2. Twin Interactions in Pure Ti Under High Strain Rate Compression

    Science.gov (United States)

    Zhou, Ping; Xiao, Dawu; Jiang, Chunli; Sang, Ge; Zou, Dongli

    2017-01-01

    Twin interactions associated with {11 overline{2} 1} (E2) twins in titanium deformed by high strain rate ( 2600 s-1) compression were studied using electron backscatter diffraction technique. Three types of twins, {10 overline{1} 2} (E1), {11 overline{2} 2} (C1), and {11 overline{2} 4} (C3), were observed to interact with the preformed E2 twins in four parent grains. The E1 variants nucleated at twin boundaries of some E2 variants. And the C3 twins were originated from the intersection of C1 and E2. The selection of twin variant was investigated by the Schmid factors (SFs) and the twinning shear displacement gradient tensors (DGTs) calculations. The results show that twin variants that did not follow the Schmid law were more frequently observed under high strain rate deformation than quasi-static deformation. Among these low-SF active variants, 73 pct (8 out of 11) can be interpreted by DGT. Besides, 26 variants that have SF values close to or higher than their active counterparts were absent. Factors that may affect the twin variant selections were discussed.

  3. ALICE TPC upgrade for High-Rate operations

    CERN Document Server

    ,

    2015-01-01

    A new type of Time Projection Chamber (TPC) has been proposed for the upgrade of the ALICE (A Large Ion Collider Experiment at CERN) so as to cater to the high luminosity environment expected at the Large Hadron Collider (LHC) facility in future. This device will rely on the intrinsic ion back flow (IBF) suppression of Micro-Pattern Gas Detectors (MPGD) based technology in particular the Gas Electron Multiplier (GEM). GEM is to minimise the space charge effect in the main drift volume and thus will not require the standard gating grid and the resulting intrinsic dead time. It will thus be possible to read all minimum bias Pb--Pb events that the Large Hadron Collider (LHC) will deliver at the anticipated peak interaction rate of 50 kHz for the high luminosity heavy-ion era in Run 3. New read-out electronics will send the continuous data stream to a new online farm at rates up to 1~TByte/s. The new read-out chambers will consist of stacks of 4 GEM foils combining different hole pitches. In addition to a low ion...

  4. Feasibility Study of High Data Rate Underwater Optical Wireless Network

    Directory of Open Access Journals (Sweden)

    V. Reji

    2014-08-01

    Full Text Available The present technology of acoustic underwater communication is a legacy of technology that provides low data rate transmission for medium range communication. In addition the speed of acoustic waves in the ocean is approximately 1500 m/sec so that long range communication involves high latency which poses a problem for a real time response and synchronization. In addition acoustic waves could distress marine mammals such as dolphins and whales. So the acoustic technology needs high data rate communication networks in real time. The growing need for underwater observation and subsea monitoring systems has stimulated considerable interest in advancing the enabling technologies of underwater wireless communication and underwater sensor networks. This communication technology is expected to play an important role in investigating climate change, in monitoring biological, biogeochemical, evolutionary and ecological changes in the sea, ocean and lake environments and in helping to control and maintain oil production facilities and harbours using unmanned underwater vehicles UUVs, submarines, ships, buoys and divers.

  5. Final Report, Photocathodes for High Repetition Rate Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, Ilan [Stony Brook University

    2014-04-20

    This proposal brought together teams at Brookhaven National Laboratory (BNL), Lawrence Berkeley National Laboratory (LBNL) and Stony Brook University (SBU) to study photocathodes for high repetition rate light sources such as Free Electron Lasers (FEL) and Energy Recovery Linacs (ERL). The work done under this grant comprises a comprehensive program on critical aspects of the production of the electron beams needed for future user facilities. Our program pioneered in situ and in operando diagnostics for alkali antimonide growth. The focus is on development of photocathodes for high repetition rate Free Electron Lasers (FELs) and Energy Recovery Linacs (ERLs), including testing SRF photoguns, both normal-conducting and superconducting. Teams from BNL, LBNL and Stony Brook University (SBU) led this research, and coordinated their work over a range of topics. The work leveraged a robust infrastructure of existing facilities and the support was used for carrying out the research at these facilities. The program concentrated in three areas: a) Physics and chemistry of alkali-antimonide cathodes b) Development and testing of a diamond amplifier for photocathodes c) Tests of both cathodes in superconducting RF photoguns and copper RF photoguns

  6. Pyrolysis kinetics of bagasse at high heating rates

    Energy Technology Data Exchange (ETDEWEB)

    Stubington, J.F.; Aiman, S. (University of New South Wales, Kensington, NSW (Australia). Dept. of Fuel Technology)

    The rate of pyrolysis of bagasse was studied at high heating rates (200-10,000 [degree]C/s) to obtain engineering data for incorporation into computational fluid dynamic models of bagasse ignition and combustion in suspension-fired and swirl burners. Experiments were performed using an electrically-heated grid under a nitrogen atmosphere at atmosphere pressure. Yields of char, tar, individual gas components, and water were measured as a function of peak temperature, for ranges of heating rate, residence time at peak temperature, and particle size. At higher peak temperatures, significant tar cracking occurred so that tar yields passed through a maximum as peak temperature increased. For dry bagasse, this tar cracking produced gases with no change in char yield, suggesting that it occurred external to the particle. Moisture in the atmosphere increased the tar cracking in the vapor phase outside the bagasse particle producing more gases but did not affect the char yield. However, moisture in the bagasse reduced the char yield and further enhanced the tar cracking reactions, producing even more gases (predominantly carbon monoxide). These results suggested an interaction between water vapor and the tar cracking reactions. For the short residence times appropriate to such burners, a single, first-order reaction model gave the best fit to the total weight loss for the ranges of heating rate and particle sizes studied. However, the first-order kinetic parameters fitted to primary tar production were recommended for modeling purposes because the total weight loss included significant yields of noncombustible water and carbon dioxide. Different ultimate primary tar yields were recommended to fit the dry and wet bagasse pyrolysis results. No chemical significance should be attributed to the kinetic parameters, which were determined to provide the simplest and best fit to the pyrolysis data. 19 refs., 15 figs., 5 tabs.

  7. High-temperature rate constant measurements for OH+xylenes

    KAUST Repository

    Elwardani, Ahmed Elsaid

    2015-06-01

    The overall rate constants for the reactions of hydroxyl (OH) radicals with o-xylene (k 1), m-xylene (k 2), and p-xylene (k 3) were measured behind reflected shock waves over 890-1406K at pressures of 1.3-1.8atm using OH laser absorption near 306.7nm. Measurements were performed under pseudo-first-order conditions. The measured rate constants, inferred using a mechanism-fitting approach, can be expressed in Arrhenius form as:k1=2.93×1013exp(-1350.3/T)cm3mol-1s-1(890-1406K)k2=3.49×1013exp(-1449.3/T)cm3mol-1s-1(906-1391K)k3=3.5×1013exp(-1407.5/T)cm3mol-1s-1(908-1383K)This paper presents, to our knowledge, first high-temperature measurements of the rate constants of the reactions of xylene isomers with OH radicals. Low-temperature rate-constant measurements by Nicovich et al. (1981) were combined with the measurements in this study to obtain the following Arrhenius expressions, which are applicable over a wider temperature range:k1=2.64×1013exp(-1181.5/T)cm3mol-1s-1(508-1406K)k2=3.05×109exp(-400/T)cm3mol-1s-1(508-1391K)k3=3.0×109exp(-440/T)cm3mol-1s-1(526-1383K) © 2015 The Combustion Institute.

  8. A high repetition rate XUV seeding source for FLASH2

    Energy Technology Data Exchange (ETDEWEB)

    Willner, Arik

    2012-05-15

    Improved performance of free-electron laser (FEL) light sources in terms of timing stability, pulse shape and spectral properties of the amplified FEL pulses is of interest in material science, the fields of ultrafast dynamics, biology, chemistry and even special branches in industry. A promising scheme for such an improvement is direct seeding with high harmonic generation (HHG) in a noble gas target. A free-electron laser seeded by an external extreme ultraviolet (XUV) source is planned for FLASH2 at DESY in Hamburg. The requirements for the XUV/soft X-ray source can be summarized as follows: A repetition rate of at least 100 kHz in a 10 Hz burst is needed at variable wavelengths from 10 to 40 nm and pulse energies of several nJ within a single laser harmonic. This application requires a laser amplifier system with exceptional parameters, mJ-level pulse energy, 10-15 fs pulse duration at 100 kHz (1 MHz) burst repetition rate. A new optical parametric chirped-pulse amplification (OPCPA) system is under development in order to meet these requirements, and very promising results have been achieved in the last three years. In parallel to this development, a new HHG concept is necessary to sustain high average power of the driving laser system and to generate harmonics with high conversion efficiencies. Currently, the highest conversion efficiency with HHG has been demonstrated using gas-filled capillary targets. For our application, only a free-jet target can be used for HHG, in order to overcome damage threshold limitations of HHG target optics at a high repetition rate. A novel dual-gas multijet gas target has been developed and first experiments show remarkable control of the degree of phase matching forming the basis for improved control of the harmonic photon flux and the XUV pulse characteristics. The basic idea behind the dual-gas concept is the insertion of matching zones in between multiple HHG sources. These matching sections are filled with hydrogen which

  9. The effect of nigellone and thymoquinone on inhibiting trachea contraction and mucociliary clearance.

    Science.gov (United States)

    Wienkötter, N; Höpner, D; Schütte, U; Bauer, K; Begrow, F; El-Dakhakhny, M; Verspohl, E J

    2008-02-01

    NIGELLA SATIVA L. has many effects including those on the gastrointestinal tract and trachea and is, therefore, used in the Mediteranean area and in India/Pakistan. Our aim was to investigate the effect of two main constituents, nigellone and thymoquinone, on trachea (antispasmodic effect) and their influence on respiratory clearance. The effects on Ba (2+)-, carbachol- and leukotriene-induced trachea contractions and the transport of the fluorescence dye rhodamin B concerning ciliary action in the tracheal area were investigated using a microdialysis technique. Nigellone and high concentrations of thymoquinone had a concentration-dependent inhibitory effect on the trachea when being contracted by the depolarizing effect of Ba (2+). The trachea contractions induced by leukotriene-d (4) were inhibited by nigellone and by thymoquinone. The cholinergic system (stimulation by carbachol) was hardly involved. The rate of ciliary clearance (mucociliary transport) was slightly modified by a high thymoquinone concentration (153.0 vs. 505.0 sec/12 mm distance, respectively), and was highly increased by nigellone (217.5 vs. 505.0 sec/12 mm distance). In conclusion, this study provides evidence for an antispasmodic effect and an increase in mucociliary clearance for nigellone but not for thymoquinone. Altogether the data indicate that nigellone but not thymoquinone may be useful in treatment of different respiratory diseases.

  10. Radionuclide Renal Dynamic Imaging GFR (glomerular filtration rate) to Evaluate Renal Function and Serum Creatinine (Scre) Evaluation Comparison of Renal Clearance%核素肾动态显像GFR测定与肌酐清除率评价肾功能的相关性比较

    Institute of Scientific and Technical Information of China (English)

    张晓; 孙莲华

    2014-01-01

    Objective:To study radionuclide renal dynamic imaging GFR ( glomerular filtration rate ) to evaluate renal function and se-rum creatinine ( Scre) evaluation comparison of renal clearance .Methods:First estimation of normal reference value of my GFR in the control group;when renal function damage of 80 cases, measurement of GFR and creatinine clearance rate comparison of measurement val-ues.Results:80 cases patients of GFR and muscle anhydride cleared rate contrast , GFR and serum muscle anhydride are exception who 63 cases, its GFR value 81.3 ±12.8ml/min and muscle anhydride cleared rate 85.5 ±11.3ml/min, differences no significantly sexual meaning (P>0.05);12 cases chronic kidney damage patients , muscle anhydride cleared rate 70.1 ±8.3ml/min,GFR value 50.2 ± 6.8ml/min, differences has significantly sexual meaning ( P<0.01); Value of 5 patients with severe hydronephrosis GFR 19.1 ±7. 3ml/min, 23.6 ±5.8ml/min creatinine clearance rate, the difference has a significant meaning (P<0.01).Radionuclide renal dynam-ic values of GFR and creatinine clearance rate more in line with;early GFR and impaired renal function creatinine clearance rate of earlier abnormal changes .Conclusion:Radionuclide renal dynamic checking GFR determination can better reflect the change rate of Glomerular filtration function in early stage , a more accurate estimation of renal function .%目的:探讨放射性核素肾动态显像GFR(肾小球滤过率)评价肾功能与血清肌酐( Scre)清除率评价肾功能的比较。方法:首先对照组估算我科GFR的正常参考值;80例当肾功能受损害时,GFR的测量值与血清肌酐清除率测定值的比较。结果:80例患者的GFR与肌酐清除率对比,GFR和血清肌酐均异常者63例,其GFR值81.3±12.8ml/min与肌酐清除率85.5±11.3ml/min,差异无显著性意义(P>0.05);12例慢性肾损害患者,肌酐清除率70.1±8.3ml/min,GFR值50.2±6.8ml

  11. High energy high rate pulsed power processing of materials by powder consolidation and by railgun deposition

    Science.gov (United States)

    Persad, C.; Marcus, H. L.; Weldon, W. F.

    1987-03-01

    This exploratory research program was initiated to investigate the potential of using pulse power sources for powder consolidation, deposition and other High Energy High Rate Processing. The characteristics of the High Energy High Rate (1MJ/s) powder consolidation using megampere current pulses from a Homopolar Generator, have been defined. Molybdenum Alloy TZM, A Nickel based metallic glass, Copper graphite composites, and P/M Aluminum Alloy X7091 have been investigated. The powder consolidation process produced high densification rates. Density values of 80% to 99% could be obtained with sub second high temperature exposure. Specific energy input and applied pressure were controlling process parameters. Time Temperature Transformation (TTT) concepts underpin a fundamental understanding of pulsed power processing. Deposition experiments were conducted using an exploding foil device (EFD) providing an armature feed to railgun mounted in a vacuum chamber. The material to be deposited - in plasma, gas, liquid or solid state - was accelerated electromagnetically in the railgun and deposited on a substrate.

  12. Aberrant expression of VEGF-C is related to grade of cervical intraepithelial neoplasia (CIN) and high risk HPV, but does not predict virus clearance after treatment of CIN or prognosis of cervical cancer.

    Science.gov (United States)

    Branca, M; Giorgi, C; Santini, D; Di Bonito, L; Ciotti, M; Benedetto, A; Paba, P; Costa, S; Bonifacio, D; Di Bonito, P; Accardi, L; Favalli, C; Syrjänen, K

    2006-01-01

    Increased angiogenesis leads to invasion in cervical cancer. Vascular endothelial growth factors (VEGFs) are involved in angiogenesis, but molecular links to the most important aetiological agent, human papillomavirus (HPV), need clarifying. Archival samples-150 squamous cell carcinomas (SCCs) and 152 cervical intraepithelial neoplasia (CIN) lesions-were examined immunohistochemically for anti-VEGF-C antibody and for HPV by polymerase chain reaction (PCR). Follow up data were available for all SCC cases, and 67 CIN lesions were monitored with serial PCR to assess HPV clearance/persistence after treatment. High risk (HR) HPV types were closely associated with CIN (odds ratio, 19.12; 95% confidence interval, 2.31 to 157.81) and SCC (27.25; 3.28 to 226.09). There was a linear increase of VEGF-C expression-weak in CIN1 and intense in CIN3 and SCC (20.49; 8.69 to 48.26). VEGF-C upregulation was a sensitive (93.5%; 95% CI, 90.1% to 96.9%) marker of HR-HPV type (4.70; 2.17 to 10.21), but lost its significance in multivariate regression-p16(INK4a) and survivin were equally strong independent predictors of HR-HPV. Aberrant expression of VEGF-C did not predict clearance/persistence of HR-HPV after treatment of CIN. In cervical cancer, VEGF-C had no prognostic value in univariate or multivariate survival analysis. After adjustment for HR-HPV, FIGO stage, age, and tumour grade, only FIGO stage and age remained independent prognostic predictors. VEGF-C is an early marker of cervical carcinogenesis, with linearly increasing expression starting from low grade CIN. VEGF-C expression is closely related to HR-HPV in cervical lesions, probably because of its p53 independent upregulation by the E6 oncoprotein of HR-HPV.

  13. The high strain-rate behaviour of selected tissue analogues.

    Science.gov (United States)

    Appleby-Thomas, G J; Hazell, P J; Sheldon, R P; Stennett, C; Hameed, A; Wilgeroth, J M

    2014-05-01

    The high strain-rate response of four readily available tissue simulants has been investigated via plate-impact experiments. Comparison of the shock response of gelatin, ballistic soap (both sub-dermal tissue simulants), lard (adipose layers) and Sylgard(®) (a potential brain simulant) allowed interrogation of the applicability of such monolithic tissue surrogates in the ballistic regime. The gelatin and lard exhibited classic linear Hugoniot equations-of-state in the US-uP plane; while for the ballistic soap and Sylgard(®) a polymer-like non-linear response was observed. In the P/σX-v/v0 plane there was evidence of separation of the simulant materials into distinct groups, suggesting that a single tissue simulant is inadequate to ensure a high-fidelity description of the high strain-rate response of complex mammalian tissue. Gelatin appeared to behave broadly hydrodynamically, while soap, lard and Sylgard(®) were observed to strengthen in a material-dependent manner under specific loading conditions at elevated shock loading pressures/stresses. This strengthening behaviour was tentatively attributed to a further polymeric-like response in the form of a re-arrangement of the molecular chains under loading (a steric effect). In addition, investigation of lateral stress data from the literature showed evidence of operation of a material-independent strengthening mechanism when these materials were stressed above 2.5-3.0GPa, tentatively linked to the generically polymeric-like underlying microstructure of the simulants under consideration.

  14. Cosmological Evolution of the Central Engine in High-Luminosity, High-Accretion Rate AGN

    Directory of Open Access Journals (Sweden)

    Matteo Guainazzi

    2014-12-01

    Full Text Available In this paper I discuss the status of observational studies aiming at probing the cosmological evolution of the central engine in high-luminosity, high-accretion rate Active Galactic Nuclei (AGN. X-ray spectroscopic surveys, supported by extensive multi-wavelength coverage, indicate a remarkable invariance of the accretion disk plus corona system, and of their coupling up to redshifts z≈6. Furthermore, hard X-ray (E >10 keV surveys show that nearby Seyfert Galaxies share the same central engine notwithstanding their optical classication. These results suggest that the high-luminosity, high accretion rate quasar phase of AGN evolution is homogeneous over cosmological times.

  15. High bit rate germanium single photon detectors for 1310nm

    Science.gov (United States)

    Seamons, J. A.; Carroll, M. S.

    2008-04-01

    There is increasing interest in development of high speed, low noise and readily fieldable near infrared (NIR) single photon detectors. InGaAs/InP Avalanche photodiodes (APD) operated in Geiger mode (GM) are a leading choice for NIR due to their preeminence in optical networking. After-pulsing is, however, a primary challenge to operating InGaAs/InP single photon detectors at high frequencies1. After-pulsing is the effect of charge being released from traps that trigger false ("dark") counts. To overcome this problem, hold-off times between detection windows are used to allow the traps to discharge to suppress after-pulsing. The hold-off time represents, however, an upper limit on detection frequency that shows degradation beginning at frequencies of ~100 kHz in InGaAs/InP. Alternatively, germanium (Ge) single photon avalanche photodiodes (SPAD) have been reported to have more than an order of magnitude smaller charge trap densities than InGaAs/InP SPADs2, which allowed them to be successfully operated with passive quenching2 (i.e., no gated hold off times necessary), which is not possible with InGaAs/InP SPADs, indicating a much weaker dark count dependence on hold-off time consistent with fewer charge traps. Despite these encouraging results suggesting a possible higher operating frequency limit for Ge SPADs, little has been reported on Ge SPAD performance at high frequencies presumably because previous work with Ge SPADs has been discouraged by a strong demand to work at 1550 nm. NIR SPADs require cooling, which in the case of Ge SPADs dramatically reduces the quantum efficiency of the Ge at 1550 nm. Recently, however, advantages to working at 1310 nm have been suggested which combined with a need to increase quantum bit rates for quantum key distribution (QKD) motivates examination of Ge detectors performance at very high detection rates where InGaAs/InP does not perform as well. Presented in this paper are measurements of a commercially available Ge APD

  16. Plasma clearance of noradrenaline does not change with age in normal subjects

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Larsen, S

    1985-01-01

    Noradrenaline kinetics (plasma concentrations, plasma clearance and appearance rates) were investigated in seven elderly healthy subjects and in six young healthy subjects. Forearm venous plasma noradrenaline concentrations were higher in the elderly subjects compared with the young subjects. Pla....... Plasma clearance of noradrenaline was identical in the two groups. The increase in plasma noradrenaline concentration, with age, probably reflects an increased sympathetic nervous activity....

  17. Celllular Uptake and Clearance of TIO2 Nanoparticles

    Science.gov (United States)

    Differential rates of cellular uptake and clearance of engineered nanomaterials may influence the propensity for tissue accumulation under chronic exposure conditions. A retinal pigment epithelial cell line (ARPE-19) was used to investigate 1) if Ti02 (Degussa, P25) nanoparticles...

  18. High frequency chest compression effects heart rate variability.

    Science.gov (United States)

    Lee, Jongwon; Lee, Yong W; Warwick, Warren J

    2007-01-01

    High frequency chest compression (HFCC) supplies a sequence of air pulses through a jacket worn by a patient to remove excessive mucus for the treatment or prevention of lung disease patients. The air pulses produced from the pulse generator propagates over the thorax delivering the vibration and compression energy. A number of studies have demonstrated that the HFCC system increases the ability to clear mucus and improves lung function. Few studies have examined the change in instantaneous heart rate (iHR) and heart rate variability (HRV) during the HFCC therapy. The purpose of this study is to measure the change of HRV with four experimental protocols: (a) without HFCC, (b) during Inflated, (c)HFCC at 6Hz, and (d) HFCC at 21Hz. The nonlinearity and regularity of HRV was assessed by approximate entropy (ApEn), a method used to quantify the complexities and randomness. To compute the ApEn, we sectioned with a total of eight epochs and displayed the ApEn over the each epoch. Our results show significant differences in the both the iHR and HRV between the experimental protocols. The iHR was elevated at both the (c) 6Hz and (d) 21Hz condition from without HFCC (10%, 16%, respectively). We also found that the HFCC system tends to increase the HRV. Our study suggests that monitoring iHR and HRV are very important physiological indexes during HFCC therapy.

  19. Remote Afterloading High Dose Rate Brachytherapy AMC EXPERIANCES

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su Gyong; Chang, Hye Sook; Choi, Eun Kyong; Yi, Byong Yong [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    1992-12-15

    Remote afterloading high dose rate brachytherapy(HDRB) is a new technology and needs new biological principle for time and dose schedule. Here, authors attempt to evaluate the technique and clinical outcome in 116 patients, 590 procedures performed at Asan Medical Center for 3 years. From Sep. 1985 to Aug 1992, 471 procedures of intracavitary radiation in 55 patients of cervical cancer and 26 of nasopharyngeal cancer, 79 intraluminal radiation in 12 of esophageal cancer, 11 of endobronchial cancer and 1 Klatskin tumor and 40 interstitial brachytherapy in 4 of breast cancer, 1 sarcoma and 1 urethral cancer were performed. Median follow-up was 7 months with range 1-31 months. All procedures except interstitial were performed under the local anesthesia and they were all well tolerated and completed the planned therapy except 6 patients. 53/58 patients with cervical cancer and 22/26 patients with nasopharynx cancer achieved CR. Among 15 patients with palliative therapy, 80% achieves palliation. We will describe the details of the technique and results in the text. To evaluate biologic effects of HDRB and optimal time/dose/fractionation schedule, we need longer follow-up. But authors feel that HDRB with proper fractionation schedule may yield superior results compared to the low dose rate brachytherapy considering the advantages of HDRB in safety factor for operator, better control of radiation dose and volume and patients comfort over the low dose brachytherapy.

  20. Modelling high data rate communication network access protocol

    Science.gov (United States)

    Khanna, S.; Foudriat, E. C.; Paterra, Frank; Maly, Kurt J.; Overstreet, C. Michael

    1990-01-01

    Modeling of high data rate communication systems is different from the low data rate systems. Three simulations were built during the development phase of Carrier Sensed Multiple Access/Ring Network (CSMA/RN) modeling. The first was a model using SIMCRIPT based upon the determination and processing of each event at each node. The second simulation was developed in C based upon isolating the distinct object that can be identified as the ring, the message, the node, and the set of critical events. The third model further identified the basic network functionality by creating a single object, the node which includes the set of critical events which occur at the node. The ring structure is implicit in the node structure. This model was also built in C. Each model is discussed and their features compared. It should be stated that the language used was mainly selected by the model developer because of his past familiarity. Further the models were not built with the intent to compare either structure or language but because the complexity of the problem and initial results contained obvious errors, so alternative models were built to isolate, determine, and correct programming and modeling errors. The CSMA/RN protocol is discussed in sufficient detail to understand modeling complexities. Each model is described along with its features and problems. The models are compared and concluding observations and remarks are presented.

  1. An Architecture for High Data Rate Very Low Frequency Communication

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2013-01-01

    Full Text Available Very low frequency (VLF communication is used for long range shore-to-ship broadcasting applications. This paper proposes an architecture for high data rate VLF communication using Gaussian minimum shift keying (GMSK modulation and low delay parity check (LDPC channel coding. Non-data aided techniques are designed and used for carrier phase synchronization, symbol timing recovery, and LDPC code frame synchronization. These require the estimation of the operative Eb/N0 for which a kurtosis based algorithm is used. Also, a method for modeling the probability density function of the received signal under the bit condition is presented in this regard. The modeling of atmospheric radio noise (ARN that corrupts VLF signals is described and an algorithm for signal enhancement in the presence of ARN in given. The BER performance of the communication system is evaluated for bit rates of 400 bps, 600 bps, and 800 bps for communication bandwidth of ~200 Hz.Defence Science Journal, 2013, 63(1, pp.25-33, DOI:http://dx.doi.org/10.14429/dsj.63.3760

  2. A short pulse, high rep-rate microdischarge VUV source

    Science.gov (United States)

    Stephens, Jacob; Fierro, Andrew; Dickens, James; Neuber, Andreas; CenterPulsed Power; Power Electronics Team

    2013-09-01

    A MOSFET based high voltage pulser is utilized to excite a microdischarge (MD), or microdischarge array (MDA) with pulsed voltages of up to 1 kV, with risetime and FWHM on the order of 10 ns and 30 ns, respectively. Additionally, the pulser is capable of pulsing at rep-rates in excess of 35 MHz. However, for these experiments the rep-rate was set on the order of 1 MHz, so as to limit excess energy deposition into the background gas and optimize the energy efficiency of VUV generation. Using VUV capable spectral diagnostics, the VUV emission of the MDs for various pressures (50-800 + Torr) and gases, focused on argon, argon-hydrogen mixtures, and neon-hydrogen mixtures (all of which provide strong emission at λ VUV emission is characterized and compared to results from transient fluid modeling of the MDA. For instance, the MDA turn-on time is recorded to be about 15 ns, which matches the full plasma development time in the model, and the MDA self- capacitance largely determines the turn-off behavior. This research was supported by an AFOSR grant on the Physics of Distributed Plasma Discharges and fellowships from the National Physical Sciences Consortium, supported by Sandia National Laboratories.

  3. High rate anaerobic thermophilic technologies for distillery wastewater treatment.

    Science.gov (United States)

    Pérez-García, M; Romero-García, L I; Rodríguez-Cano, R; Sales-Márquez, D

    2005-01-01

    In this paper, performance of two high rate technologies, upflow anaerobic fixed-film reactor and fluidized bed laboratory-scale, treating distillery wastewater (wine vinasses) at anaerobic thermophilic conditions have been compared. The results obtained show that the stationary packed bed, with a corrugated plastic support, operated under stable conditions at organic loading rates (OLR0) around 20 kgCOD/m3/d, gives maximal total CODr of 76% at OLR0 of 6.29 kgCOD/m3/d; the fluidized bed reactor, operated on open pore sintered-glass media, gives total CODr of 96% at OLR0 of 5.88 kgCOD/m3/d. The anaerobic fluidized bed technology is more effective than the upflow anaerobic fixed-film technology due, fundamentally, to this technology favouring the transport of microbial cells from the bulk to the surface and enhancing the contact between the microorganism-substrate phases, In this sense, the stationary packed bed technology is adequate for the treatment of easily biodegradable wastewater, or for the cases where elevated percentages of CODr removal are not required, while the fluidized bed technology is especially suitable for treatment of hazardous wastes with recalcitrant compositions.

  4. High strain rate superplastic aluminium alloys: the way forward?

    Energy Technology Data Exchange (ETDEWEB)

    Grimes, R.; Dashwood, R.J.; Flower, H.M. [Imperial Coll. of Science, Technology and Medicine, London (United Kingdom). Dept. of Materials

    2001-07-01

    The technical and commercial barriers to the development and successful exploitation of a high strain rate superplastically deformable aluminium alloy for use in the automotive industry are considered in this paper. Batch processing routes, such as mechanical alloying or equal channel angular extrusion, employed to deliver appropriate chemistry and structure, are inherently costly and unlikely to deliver either the quantity or the size of strip required commercially. There is evidence that there is still scope for development of conventional casting and rolling routes, but a particulate casting route combined with roll consolidation offers the prospect of a commercially viable Al-Mg-Zr product. The use of alloying additions, including zirconium, is also discussed and comparative costs are presented: on this basis the use of scandium appears economically prohibitive. (orig.)

  5. FORECASTING INFLATION RATES WITH HIGH ORDER FUZZY TIME SERIES APPROACH

    Directory of Open Access Journals (Sweden)

    VEDİDE REZAN USLU

    2013-06-01

    Full Text Available To obtain inflation forecasts is an important economic issue. The more accurate forecasts we get implies the more precise decisions we make. The central Bank reports inflation rates in certain periods of every year. In this reports the results of inflation expectation survey are presented. In this study we use an approach in which relationship is determined by artificial neural network in high order fuzzy time series model. Time series of consumer price index is estimated by both the artificial neural network based method and some fuzzy approaches which is common in the literature. The results are compared to the results of inflation expectation survey analysis conducted by Central Bank of the Republic of Turkey in the aspect of forecasts accuracy.

  6. Ka-band MMIC microstrip array for high rate communications

    Science.gov (United States)

    Lee, R. Q.; Raquet, C. A.; Tolleson, J. B.; Sanzgiri, S. M.

    1991-01-01

    In a recent technology assessment of alternative communication systems for the space exploration initiative (SEI), Ka-band (18 to 40 GHz) communication technology was identified to meet the mission requirements of telecommunication, navigation, and information management. Compared to the lower frequency bands, Ka-band antennas offer higher gain and broader bandwidths; thus, they are more suitable for high data rate communications. Over the years, NASA has played an important role in monolithic microwave integrated circuit (MMIC) phased array technology development, and currently, has an ongoing contract with Texas Instrument (TI) to develop a modular Ka-band MMIC microstrip subarray (NAS3-25718). The TI contract emphasizes MMIC integration technology development and stipulates using existing MMIC devices to minimize the array development cost. The objective of this paper is to present array component technologies and integration techniques used to construct the subarray modules.

  7. Wastewater treatment high rate algal ponds for biofuel production.

    Science.gov (United States)

    Park, J B K; Craggs, R J; Shilton, A N

    2011-01-01

    While research and development of algal biofuels are currently receiving much interest and funding, they are still not commercially viable at today's fossil fuel prices. However, a niche opportunity may exist where algae are grown as a by-product of high rate algal ponds (HRAPs) operated for wastewater treatment. In addition to significantly better economics, algal biofuel production from wastewater treatment HRAPs has a much smaller environmental footprint compared to commercial algal production HRAPs which consume freshwater and fertilisers. In this paper the critical parameters that limit algal cultivation, production and harvest are reviewed and practical options that may enhance the net harvestable algal production from wastewater treatment HRAPs including CO(2) addition, species control, control of grazers and parasites and bioflocculation are discussed. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. Parallel Modem Architectures for High-Data-Rate Space Modems

    Science.gov (United States)

    Satorius, E.

    2014-08-01

    Existing software-defined radios (SDRs) for space are limited in data volume by several factors, including bandwidth, space-qualified analog-to-digital converter (ADC) technology, and processor throughput, e.g., the throughput of a space-qualified field-programmable gate array (FPGA). In an attempt to further improve the throughput of space-based SDRs and to fully exploit the newer and more capable space-qualified technology (ADCs, FPGAs), we are evaluating parallel transmitter/receiver architectures for space SDRs. These architectures would improve data volume for both deep-space and particularly proximity (e.g., relay) links. In this article, designs for FPGA implementation of a high-rate parallel modem are presented as well as both fixed- and floating-point simulated performance results based on a functional design that is suitable for FPGA implementation.

  9. Single chain stochastic polymer modeling at high strain rates.

    Energy Technology Data Exchange (ETDEWEB)

    Harstad, E. N. (Eric N.); Harlow, Francis Harvey,; Schreyer, H. L.

    2001-01-01

    Our goal is to develop constitutive relations for the behavior of a solid polymer during high-strain-rate deformations. In contrast to the classic thermodynamic techniques for deriving stress-strain response in static (equilibrium) circumstances, we employ a statistical-mechanics approach, in which we evolve a probability distribution function (PDF) for the velocity fluctuations of the repeating units of the chain. We use a Langevin description for the dynamics of a single repeating unit and a Lioville equation to describe the variations of the PDF. Moments of the PDF give the conservation equations for a single polymer chain embedded in other similar chains. To extract single-chain analytical constitutive relations these equations have been solved for representative loading paths. By this process we discover that a measure of nonuniform chain link displacement serves this purpose very well. We then derive an evolution equation for the descriptor function, with the result being a history-dependent constitutive relation.

  10. Resistive Wall Heating of the Undulator in High Repetition Rate

    Energy Technology Data Exchange (ETDEWEB)

    Qiang, J; Corlett, J; Emma, P; Wu, J

    2012-05-20

    In next generation high repetition rate FELs, beam energy loss due to resistive wall wakefields will produce significant amount of heat. The heat load for a superconducting undulator (operating at low temperature), must be removed and will be expensive to remove. In this paper, we study this effect in an undulator proposed for a Next Generation Light Source (NGLS) at LBNL. We benchmark our calculations with measurements at the LCLS and carry out detailed parameter studies using beam from a start-to-end simulation. Our preliminarym results suggest that the heat load in the undulator is about 2 W/m or lower with an aperture size of 6 mm for nominal NGLS preliminary design parameters.

  11. Combination of OFDM and CDMA for high data rate UWB

    CERN Document Server

    Guéguen, Emeric; Hélard, Jean-François; Crussière, Matthieu

    2006-01-01

    For Wireless Personal Area Network (WPAN) systems, resource allocation between several users within a piconet and the coexistence of several piconets are very important points to take into consideration for the optimization of high data rate Ultra Wide Band (UWB) systems. To improve the performance of the Multi-Band OFDM (Orthogonal Frequency Division Multiplex) solution proposed by the Multi-Band OFDM Alliance (MBOA), the addition of a spreading component in the frequency domain is a good solution since it makes resource allocation easier and also offers better robustness against channel frequency selectivity and narrowband interference. The Spread Spectrum - Multi-Carrier - Multiple Access (SS-MC-MA) system proposed in this article offers not only the advantages of Multi-Carrier - Coded Division Multiple Access (MC-CDMA) brought by frequency spreading, but also a more effective dynamic resource allocation in a multi-user and multi-piconet context. These improvements are obtained without increasing the compl...

  12. Performance of high-rate gravel-packed oil wells

    Energy Technology Data Exchange (ETDEWEB)

    Unneland, Trond

    2001-05-01

    Improved methods for the prediction, evaluation, and monitoring of performance in high-rate cased-hole gravel-packed oil wells are presented in this thesis. The ability to predict well performance prior to the gravel-pack operations, evaluate the results after the operation, and monitor well performance over time has been improved. This lifetime approach to performance analysis of gravel-packed oil wells contributes to increase oil production and field profitability. First, analytical models available for prediction of performance in gravel-packed oil wells are reviewed, with particular emphasis on high-velocity flow effects. From the analysis of field data from three North Sea oil fields, improved and calibrated cased-hole gravel-pack performance prediction models are presented. The recommended model is based on serial flow through formation sand and gravel in the perforation tunnels. In addition, new correlations for high-velocity flow in high-rate gravel-packed oil wells are introduced. Combined, this improves the performance prediction for gravel-packed oil wells, and specific areas can be targeted for optimized well design. Next, limitations in the current methods and alternative methods for evaluation and comparison of well performance are presented. The most widely used parameter, the skin factor, remains a convenient and important parameter. However, using the skin concept in direct comparisons between wells with different reservoir properties may result in misleading or even invalid conclusions. A discussion of the parameters affecting the skin value, with a clarification of limitations, is included. A methodology for evaluation and comparison of gravel-packed well performance is presented, and this includes the use of results from production logs and the use of effective perforation tunnel permeability as a parameter. This contributes to optimized operational procedures from well to well and from field to field. Finally, the data sources available for

  13. Fast Timing for High-Rate Environments with Micromegas

    CERN Document Server

    Papaevangelou, Thomas; Ferrer-Ribas, Esther; Giomataris, Ioannis; Godinot, Cyprien; Gonzalez Diaz, Diego; Gustavsson, Thomas; Kebbiri, Mariam; Oliveri, Eraldo; Resnati, Filippo; Ropelewski, Leszek; Tsiledakis, Georgios; Veenhof, Rob; White, Sebastian

    2016-01-01

    The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation). We demonstrate a Micromegas based solution to reach this level of performance. The Micromegas acts as a photomultiplier coupled to a Cerenkov-radiator front window, which produces sufficient UV photons to convert the ~100 ps single-photoelectron jitter into a timing response of the order of 10-20 ps per incident charged particle. A prototype has been built in order to demonstrate this performance. The first laboratory tests with a pico-second laser have shown a time resolution of the order of 27 ps for ~50 primary photoelectrons, using a bulk Micromegas readout.

  14. An integrated CMOS high data rate transceiver for video applications

    Science.gov (United States)

    Yaping, Liang; Dazhi, Che; Cheng, Liang; Lingling, Sun

    2012-07-01

    This paper presents a 5 GHz CMOS radio frequency (RF) transceiver built with 0.18 μm RF-CMOS technology by using a proprietary protocol, which combines the new IEEE 802.11n features such as multiple-in multiple-out (MIMO) technology with other wireless technologies to provide high data rate robust real-time high definition television (HDTV) distribution within a home environment. The RF frequencies cover from 4.9 to 5.9 GHz: the industrial, scientific and medical (ISM) band. Each RF channel bandwidth is 20 MHz. The transceiver utilizes a direct up transmitter and low-IF receiver architecture. A dual-quadrature direct up conversion mixer is used that achieves better than 35 dB image rejection without any on chip calibration. The measurement shows a 6 dB typical receiver noise figure and a better than 33 dB transmitter error vector magnitude (EVM) at -3 dBm output power.

  15. An integrated CMOS high data rate transceiver for video applications

    Institute of Scientific and Technical Information of China (English)

    Liang Yaping; Che Dazhi; Liang Cheng; Sun Lingling

    2012-01-01

    This paper presents a 5 GHz CMOS radio frequency (RF) transceiver built with 0.18 μm RF-CMOS technology hy using a proprietary protocol,which combines the new IEEE 802.11n features such as multiplein multiple-out (MIMO) technology with other wireless technologies to provide high data rate robust real-time high definition television (HDTV) distribution within a home environment.The RF frequencies cover from 4.9 to 5.9 GHz:the industrial,scientific and medical (ISM) band.Each RF channel bandwidth is 20 MHz.The transceiver utilizes a direct up transmitter and low-IF receiver architecture.A dual-quadrature direct up conversion mixer is used that achieves better than 35 dB image rejection without any on chip calibration.The measurement shows a 6 dB typical receiver noise figure and a better than 33 dB transmitter error vector magnitude (EVM) at -3 dBm output power.

  16. Metrology challenges for high-rate nanomanufacturing of polymer structures

    Science.gov (United States)

    Mead, Joey; Barry, Carol; Busnaina, Ahmed; Isaacs, Jacqueline

    2012-10-01

    The transfer of nanoscience accomplishments into commercial products is hindered by the lack of understanding of barriers to nanoscale manufacturing. We have developed a number of nanomanufacturing processes that leverage available high-rate plastics fabrication technologies. These processes include directed assembly of a variety of nanoelements, such as nanoparticles and nanotubes, which are then transferred onto a polymer substrate for the fabrication of conformal/flexible electronic materials, among other applications. These assembly processes utilize both electric fields and/or chemical functionalization. Conducting polymers and carbon nanotubes have been successfully transferred to a polymer substrate in times less than 5 minutes, which is commercially relevant and can be utilized in a continuous (reel to reel/roll to roll) process. Other processes include continuous high volume mixing of nanoelements (CNTs, etc) into polymers, multi-layer extrusion and 3D injection molding of polymer structures. These nanomanufacturing processes can be used for wide range of applications, including EMI shielding, flexible electronics, structural materials, and novel sensors (specifically for chem/bio detection). Current techniques to characterize the quality and efficacy of the processes are quite slow. Moreover, the instrumentation and metrology needs for these manufacturing processes are varied and challenging. Novel, rapid, in-line metrology to enable the commercialization of these processes is critically needed. This talk will explore the necessary measurement needs for polymer based nanomanufacturing processes for both step and continuous (reel to reel/roll to roll) processes.

  17. Effectiveness of high interest rate policy on exchange rates: A reexamination of the Asian financial crisis

    OpenAIRE

    Chin Diew Lai; Penm, Jack H. W.; Tim Brailsford

    2006-01-01

    One of the most controversial issues in the aftermath of the Asian financial crisis has been the appropriate response of monetary policy to a sharp decline in the value of some currencies. In this paper, we empirically examine the effects on Asian exchange rates of sharply higher interest rates during the Asian financial crisis. Taking account of the currency contagion effect, our results indicate that sharply higher interest rates helped to support the exchange rates of ...

  18. Effectiveness of high interest rate policy on exchange rates: A reexamination of the Asian financial crisis

    OpenAIRE

    2006-01-01

    One of the most controversial issues in the aftermath of the Asian financial crisis has been the appropriate response of monetary policy to a sharp decline in the value of some currencies. In this paper, we empirically examine the effects on Asian exchange rates of sharply higher interest rates during the Asian financial crisis. Taking account of the currency contagion effect, our results indicate that sharply higher interest rates helped to support the exchange rates of South Korea, the Phil...

  19. The strain-rate sensitivity of high-strength high-toughness steels.

    Energy Technology Data Exchange (ETDEWEB)

    Dilmore, M.F. (AFRL/MNMW, Eglin AFB, FL); Crenshaw, Thomas B.; Boyce, Brad Lee

    2006-01-01

    The present study examines the strain-rate sensitivity of four high strength, high-toughness alloys at strain rates ranging from 0.0002 s-1 to 200 s-1: Aermet 100, a modified 4340, modified HP9-4-20, and a recently developed Eglin AFB steel alloy, ES-1c. A refined dynamic servohydraulic method was used to perform tensile tests over this entire range. Each of these alloys exhibit only modest strain-rate sensitivity. Specifically, the strain-rate sensitivity exponent m, is found to be in the range of 0.004-0.007 depending on the alloy. This corresponds to a {approx}10% increase in the yield strength over the 7-orders of magnitude change in strain-rate. Interestingly, while three of the alloys showed a concominant {approx}3-10% drop in their ductility with increasing strain-rate, the ES1-c alloy actually exhibited a 25% increase in ductility with increasing strain-rate. Fractography suggests the possibility that at higher strain-rates ES-1c evolves towards a more ductile dimple fracture mode associated with microvoid coalescence.

  20. Fiber-optic laser Doppler turbine tip clearance probe.

    Science.gov (United States)

    Büttner, Lars; Pfister, Thorsten; Czarske, Jürgen

    2006-05-01

    A laser Doppler based method for in situ single blade tip clearance measurements of turbomachines with high precision is presented for what we believe is the first time. The sensor is based on two superposed fanlike interference fringe systems generated by two laser wavelengths from a fiber-coupled, passive, and therefore compact measurement head employing diffractive optics. Tip clearance measurements at a transonic centrifugal compressor performed during operation at 50,000 rpm (833 Hz, 586 m/s tip speed) are reported. At these speeds the measured uncertainty of the tip position was less than 20 microm, a factor of 2 more accurate than that of capacitive probes. The sensor offers great potential for in situ and online high-precision tip clearance measurements of metallic and nonmetallic turbine blades.

  1. New liquid cathode electrolytes in high rate cells

    Science.gov (United States)

    Bailey, Jean W.; Kalisz, David W.; Blomgren, George E.

    1990-03-01

    The power limitations of liquid oxyhalide batteries were explored by examining the physical and electrical properties of new electrolytes. Conductivity, kinematic viscosity, and specific gravity of electrolytes were measured inside a specially adapted argon filled drybox. Liquid cathode oxyhalide electrolytes designed to enhance power density were tested first in demountable test cells and then, the most promising, in hermetically sealed high rate F size jellyroll cells. For F cells, the capacity on constant current discharge was measured at 3.5 and 12.5 mA/sq cm for fresh cells at 21 C and at 3.5 mA/sq cm for cells stored 4 weeks at 54 C then discharged at -30 C. An optimized cell design with thicker electrodes was developed for testing electrolytes with higher conductivity than LiAlCl4-SOCl2. The best capacity at 2A was achieved with LiGaCl4-SOCl2 or LiAlCl4-SOCl2. The best capacity at 7A was achieved with LiGaCl4-SOCl2. LiGaCl4 in SOCl2 was found to discharge at higher temperatures than LiAlCl4 in SOCl2. Imidazolium, aralkylammonium, and sulfonium chlorides were found to have high solubility and conductivity in thionyl chloride, but lithium was found to be passive in contact with these solutions and most metals corroded excessively. These salts mixed with aluminum chloride were much less aggressive and when mixed with lithium salts in addition gave high conductivity and test cell capacities.

  2. High rate of Helicobacter pylori reinfection in Lithuanianpeptic ulcer patients

    Institute of Scientific and Technical Information of China (English)

    2016-01-01

    AIM To evaluate the frequency of Helicobacter pylori (H.pylori ) reinfection in peptic ulcer patients during 9 yearsafter H. pylori eradication.METHODS: We invited 117 peptic ulcer patients inwhom eradication of H. pylori was confirmed 1 yearafter eradication treatment both by histology and byrapid urease test. In total, 57 patients were availablefor the study procedures: 34 (59.6%) male, 23 (40.4%)female; mean age 52.3 ± 13.0 years. There were 45(78.9%) patients with duodenal ulcer and 12 (21.1%)with gastric ulcer. H. pylori was diagnosed by a rapidurease test and histology if endoscopy was performed.If endoscopy was refused, H. pylori was diagnosed bythe C14-urea breath test and serology. H. pylori wasestablished if at least one of the tests was positive.RESULTS: The mean follow-up was 8.9 ± 1.0 years(range, 6-12). H. pylori was established in 15 patients.In 2 H. pylori -negative patients, H. pylori was establishedduring the follow-up period and eradicated. Therefore,we consider that reinfection occurred in 17 patients. Inthe per protocol analysis, reinfection was established in17 of 57 (29.8%; 95%CI: 19.2-42.2) patients during thefollow-up period. The annual rate of infection was 3.36%.If all non-responders were considered H. pylori -negative,reinfection would be 14.5% (17/117), the annual rate being 1.63%. The mean age of patients with reinfectionwas 51.8 ± 14.0 years, and without reinfection was52.5 ± 13.0 years, P 〉 0.05; the mean body massindex of patients with reinfection was 27.2 ± 4.1 kg/m2,and without reinfection was 25.7 ± 4.2 kg/m2, P 〉0.05. There were no differences in the reinfection ratesaccording the location of the peptic ulcer, the eradicationregimen used, and smoking status.CONCLUSION: The reinfection rate of H. pylori isrelatively high in Lithuania and probably related to thehigh prevalence of H. pylori , what may reflect differencesin the socioeconomic status between Western and

  3. Esophageal Acid Clearance Is Faster in Patients with Barrett's Esophagus Than in Healthy Controls During Random Swallowing

    DEFF Research Database (Denmark)

    Lottrup, Christian; Krarup, Anne Petas Swane; Gregersen, Hans;

    2016-01-01

    Background/Aims: Impaired esophageal acid clearance may be a contributing factor in the pathogenesis of Barrett's esophagus. However, few studies have measured acid clearance as such in these patients. In this explorative, cross-sectional study, we aimed to compare esophageal acid clearance...... and swallowing rate in patients with Barrett's esophagus to that in healthy controls. Methods: A total of 26 patients with histology-confirmed Barrett's esophagus and 12 healthy controls underwent (1) upper endoscopy, (2) an acid clearance test using a pH-impedance probe under controlled conditions including...... clearance test were not correlated (all P > 0.3). Conclusions: More frequent swallowing and thus faster acid clearance in Barrett's esophagus may constitute a protective reflex due to impaired mucosal integrity and possibly acid hypersensitivity. Despite these reinforced mechanisms, acid clearance ability...

  4. Physiotherapy for airway clearance in adults.

    Science.gov (United States)

    Pryor, J A

    1999-12-01

    Techniques for augmenting, when necessary, the normal mucociliary and cough clearance mechanisms of the lungs are not new, but, in more recent years, techniques have been developed which are effective, comfortable and can be used independent of an assistant in the majority of adolescents and adults. Postural drainage with chest clapping and chest shaking has, in most parts of the world, been replaced by the more effective techniques of the active cycle of breathing, autogenic drainage, R-C Cornet, Flutter, positive expiratory pressure mask, high-frequency chest wall oscillation and intrapulmonary percussive ventilation. Glossopharyngeal breathing is being considered again and is often a useful technique for increasing the effectiveness of cough in patients with tetraplegia or neuromuscular disorders. The evidence in support of these techniques is variable, and the literature is confusing and conflicting. There may or may not be significant differences among the techniques in the short or long term. Many of the regimens now include the forced expiratory manoeuvre of a "huff" and this has probably increased the effectiveness of airway clearance. If objective differences are small, individual preferences and cultural influences may be significant in increasing adherence to treatment and in the selection of an appropriate regimen or regimens for an individual patient.

  5. Algal biofuels from wastewater treatment high rate algal ponds.

    Science.gov (United States)

    Craggs, R J; Heubeck, S; Lundquist, T J; Benemann, J R

    2011-01-01

    This paper examines the potential of algae biofuel production in conjunction with wastewater treatment. Current technology for algal wastewater treatment uses facultative ponds, however, these ponds have low productivity (∼10 tonnes/ha.y), are not amenable to cultivating single algal species, require chemical flocculation or other expensive processes for algal harvest, and do not provide consistent nutrient removal. Shallow, paddlewheel-mixed high rate algal ponds (HRAPs) have much higher productivities (∼30 tonnes/ha.y) and promote bioflocculation settling which may provide low-cost algal harvest. Moreover, HRAP algae are carbon-limited and daytime addition of CO(2) has, under suitable climatic conditions, the potential to double production (to ∼60 tonnes/ha.y), improve bioflocculation algal harvest, and enhance wastewater nutrient removal. Algae biofuels (e.g. biogas, ethanol, biodiesel and crude bio-oil), could be produced from the algae harvested from wastewater HRAPs, The wastewater treatment function would cover the capital and operation costs of algal production, with biofuel and recovered nutrient fertilizer being by-products. Greenhouse gas abatement results from both the production of the biofuels and the savings in energy consumption compared to electromechanical treatment processes. However, to achieve these benefits, further research is required, particularly the large-scale demonstration of wastewater treatment HRAP algal production and harvest.

  6. ASAS Eclipsing Binaries with Observed High Period Change Rates

    CERN Document Server

    Pilecki, B; Poleski, R

    2007-01-01

    We present 31 bright eclipsing contact and semi-detached binaries that showed high period change rates in a 5 year interval in observations by the All-Sky Automated Survey (ASAS). The time-scales of these changes range from only 50 up to 400 kyr. The orbital periods of 10 binaries are increasing and of 21 are decreasing, and even a larger excess is seen in contact binaries, where the numbers are 5 and 17, respectively. Period change has previously been noticed for only two of these binaries; our observations confirmed a secular period drift for SV Cen and period oscillations for VY Cet. The spectroscopic quadruple system V1084 Sco shows both period change and brightness modulation. All investigated binaries were selected from a sample of 1711 (1135 contact and 576 semi-detached) that fulfilled all criteria of data quality. We also introduce a "branch" test to check if luminosity changes on part of the binary's photosphere has led to a spurious or poorly characterized period change detection.

  7. Image-guided high dose rate endorectal brachytherapy.

    Science.gov (United States)

    Devic, Slobodan; Vuong, Té; Moftah, Belal; Evans, Michael; Podgorsak, Ervin B; Poon, Emily; Verhaegen, Frank

    2007-11-01

    Fractionated high dose rate endorectal brachytherapy (HDR-EBT) using CT-based treatment planning is an alternative method for preoperative down-sizing and down-staging of advanced rectal adeno-carcinomas. The authors present an image guidance procedure that was developed to ensure daily dose reproducibility for the four brachytherapy treatment fractions. Since the applicator might not be placed before each treatment fraction inside the rectal lumen in the same manner as it was placed during the 3D CT volume acquisition used for treatment planning, there is a shift along the catheter axis that may have to be performed. The required shift is determined by comparison of a daily radiograph with the treatment planning digitally-reconstructed radiograph (DRR). A procedure is developed for DRR reconstruction from the 3D data set used for the treatment planning, and two possible daily longitudinal shifts are illustrated: above and below the planning dose distribution. The authors also describe the procedure for rotational alignment illustrated on a clinical case. Reproduction of the treatment planned dose distribution on a daily basis is crucial for the success of fractionated 3D based brachytherapy treatments. Due to the cylindrical symmetry of the applicator used for preoperative HDR-EBT, two types of adjustments are necessary: applicator rotation and dwell position shift along the applicator's longitudinal axis. The impact of the longitudinal applicator shift prior to treatment delivery for 62 patients treated in our institution is also assessed.

  8. Pregnancy after kidney transplantation: high rates of maternal complications

    Directory of Open Access Journals (Sweden)

    Cristina Candido

    Full Text Available Abstract Introduction: Women regain fertility a few time after renal transplantation. However, viability of pregnancy and maternal complications are still unclear. Objective: To describe the outcomes of pregnancies in kidney transplanted patients, focusing on maternal complications. Methods: Retrospective study of pregnancies in kidney transplanted patients between 2004 and 2014, followed up 12 months after delivery. Each pregnancy was considered an event. Results: There were 53 pregnancies in 36 patients. Mean age was 28 ± 5years. Pregnancy occurred 4.4 ± 3.0 years post-transplant. Immunosuppression before conception was tacrolimus, azathioprine, and prednisone in 74% of the cases. There were 15% miscarriages in the 1st trimester and 8% in 2nd trimester. In 41% of the cases, it was necessary to induce labor. From all births, 22% were premature and 17% very premature. There were 5% stillbirths and 5% of neonatal deaths. De novo proteinuria occurred in 60%, urinary tract infection in 23%, preeclampsia in 11%, acute rejection in 6%, and graft loss in 2% of the cases. It was observed a significant increase in creatinine at preconception comparing to 3rd trimester and follow-up (1.17 vs. 1.46 vs. 1.59 mg/dL, p < 0.001. Conclusion: Although the sample is limited, the number of miscarriages was higher than in the general population, with high rates of maternal complications. Sustained increase of creatinine suggests increased risk of graft loss in long-term.

  9. Smart Payload Development for High Data Rate Instrument Systems

    Science.gov (United States)

    Pingree, Paula J.; Norton, Charles D.

    2007-01-01

    This slide presentation reviews the development of smart payloads instruments systems with high data rates. On-board computation has become a bottleneck for advanced science instrument and engineering capabilities. In order to improve the computation capability on board, smart payloads have been proposed. A smart payload is a Localized instrument, that can offload the flight processor of extensive computing cycles, simplify the interfaces, and minimize the dependency of the instrument on the flight system. This has been proposed for the Mars mission, Mars Atmospheric Trace Molecule Spectroscopy (MATMOS). The design of this system is discussed; the features of the Virtex-4, are discussed, and the technical approach is reviewed. The proposed Hybrid Field Programmable Gate Array (FPGA) technology has been shown to deliver breakthrough performance by tightly coupling hardware and software. Smart Payload designs for instruments such as MATMOS can meet science data return requirements with more competitive use of available on-board resources and can provide algorithm acceleration in hardware leading to implementation of better (more advanced) algorithms in on-board systems for improved science data return

  10. ASIC for High Rate 3D Position Sensitive Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Vernon, E.; De Geronimo, G.; Ackley, K.; Fried, J.; He, Z.; Herman, C.; Zhang, F.

    2010-06-16

    We report on the development of an application specific integrated circuit (ASIC) for 3D position sensitive detectors (3D PSD). The ASIC is designed to operate with pixelated wide bandgap sensors like Cadmium-Zinc-Telluride (CZT), Mercuric Iodide (Hgl2) and Thallium Bromide (TIBr). It measures the amplitudes and timings associated with an ionizing event on 128 anodes, the anode grid, and the cathode. Each channel provides low-noise charge amplification, high-order shaping with peaking time adjustable from 250 ns to 12 {micro}s, gain adjustable to 20 mV/fC or 120 mV/fC (for a dynamic range of 3.2 MeV and 530 keV in CZT), amplitude discrimination with 5-bit trimming, and positive and negative peak and timing detections. The readout can be full or sparse, based on a flag and single- or multi-cycle token passing. All channels, triggered channels only, or triggered with neighbors can be read out thus increasing the rate capability of the system to more than 10 kcps. The ASIC dissipates 330 mW which corresponds to about 2.5 mW per channel.

  11. Preliminary Diffusive Clearance of Silicon Nanopore Membranes in a Parallel Plate Configuration for Renal Replacement Therapy

    Science.gov (United States)

    Kim, Steven; Heller, James; Iqbal, Zohora; Kant, Rishi; Kim, Eun Jung; Durack, Jeremy; Saeed, Maythem; Do, Loi; Hetts, Steven; Wilson, Mark; Brakeman, Paul; Fissell, William H.; Roy, Shuvo

    2015-01-01

    Silicon nanopore membranes (SNM) with compact geometry and uniform pore size distribution have demonstrated a remarkable capacity for hemofiltration. These advantages could potentially be used for hemodialysis. Here we present an initial evaluation of the SNM’s mechanical robustness, diffusive clearance, and hemocompatibility in a parallel plate configuration. Mechanical robustness of the SNM was demonstrated by exposing membranes to high flows (200ml/min) and pressures (1,448mmHg). Diffusive clearance was performed in an albumin solution and whole blood with blood and dialysate flow rates of 25ml/min. Hemocompatibility was evaluated using scanning electron microscopy and immunohistochemistry after 4-hours in an extra-corporeal porcine model. The pressure drop across the flow cell was 4.6mmHg at 200ml/min. Mechanical testing showed that SNM could withstand up to 775.7mmHg without fracture. Urea clearance did not show an appreciable decline in blood versus albumin solution. Extra-corporeal studies showed blood was successfully driven via the arterial-venous pressure differential without thrombus formation. Bare silicon showed increased cell adhesion with a 4.1 fold increase and 1.8 fold increase over polyethylene-glycol (PEG)-coated surfaces for tissue plasminogen factor (t-PA) and platelet adhesion (CD-41), respectively. These initial results warrant further design and development of a fully scaled SNM-based parallel plate dialyzer for renal replacement therapy. PMID:26692401

  12. Preliminary Diffusive Clearance of Silicon Nanopore Membranes in a Parallel Plate Configuration for Renal Replacement Therapy.

    Science.gov (United States)

    Kim, Steven; Heller, James; Iqbal, Zohora; Kant, Rishi; Kim, Eun Jung; Durack, Jeremy; Saeed, Maythem; Do, Loi; Hetts, Steven; Wilson, Mark; Brakeman, Paul; Fissell, William H; Roy, Shuvo

    2016-01-01

    Silicon nanopore membranes (SNMs) with compact geometry and uniform pore size distribution have demonstrated a remarkable capacity for hemofiltration. These advantages could potentially be used for hemodialysis. Here, we present an initial evaluation of the SNM's mechanical robustness, diffusive clearance, and hemocompatibility in a parallel plate configuration. Mechanical robustness of the SNM was demonstrated by exposing membranes to high flows (200 ml/min) and pressures (1,448 mm Hg). Diffusive clearance was performed in an albumin solution and whole blood with blood and dialysate flow rates of 25 ml/min. Hemocompatibility was evaluated using scanning electron microscopy and immunohistochemistry after 4 hours in an extracorporeal porcine model. The pressure drop across the flow cell was 4.6 mm Hg at 200 ml/min. Mechanical testing showed that SNM could withstand up to 775.7 mm Hg without fracture. Urea clearance did not show an appreciable decline in blood versus albumin solution. Extracorporeal studies showed blood was successfully driven via the arterial-venous pressure differential without thrombus formation. Bare silicon showed increased cell adhesion with a 4.1-fold increase and 1.8-fold increase over polyethylene glycol (PEG)-coated surfaces for tissue plasminogen factor (t-PA) and platelet adhesion (CD41), respectively. These initial results warrant further design and development of a fully scaled SNM-based parallel plate dialyzer for renal replacement therapy.

  13. High power, high repetition rate, few picosecond Nd:LuVO₄ oscillator with cavity dumping.

    Science.gov (United States)

    Gao, Peng; Guo, Jie; Li, Jinfeng; Lin, Hua; Yu, Haohai; Zhang, Huaijin; Liang, Xiaoyan

    2015-12-28

    We investigate the potential use of Nd:LuVO4 in high average power, high repetition rate ultrafast lasers. Maximum mode-locked average power of 28 W is obtained at the repetition rate of 58 MHz. The shortest pulse duration is achieved at 4 ps without dispersion compensation. With a cavity dumping technique, the pulse energy is scaling up to 40.7 μJ at 300 kHz and 14.3 μJ at 1.5 MHz.

  14. Hepatic insulin clearance is closely related to metabolic syndrome components.

    Science.gov (United States)

    Pivovarova, Olga; Bernigau, Wolfgang; Bobbert, Thomas; Isken, Frank; Möhlig, Matthias; Spranger, Joachim; Weickert, Martin O; Osterhoff, Martin; Pfeiffer, Andreas F H; Rudovich, Natalia

    2013-11-01

    Insulin clearance is decreased in type 2 diabetes mellitus (T2DM) for unknown reasons. Subjects with metabolic syndrome are hyperinsulinemic and have an increased risk of T2DM. We aimed to investigate the relationship between hepatic insulin clearance (HIC) and different components of metabolic syndrome and tested the hypothesis that HIC may predict the risk of metabolic syndrome. Individuals without diabetes from the Metabolic Syndrome Berlin Brandenburg (MeSyBePo) study (800 subjects with the baseline examination and 189 subjects from the MeSyBePo recall study) underwent an oral glucose tolerance test (OGTT) with assessment of insulin secretion (insulin secretion rate [ISR]) and insulin sensitivity. Two indices of HIC were calculated. Both HIC indices showed lower values in subjects with metabolic syndrome (P < 0.001) at baseline. HIC indices correlate inversely with waist circumference, diastolic blood pressure, fasting glucose, triglycerides, and OGTT-derived insulin secretion index. During a mean follow-up of 5.1 ± 0.9 years, 47 individuals developed metabolic syndrome and 33 subjects progressed to impaired glucose metabolism. Both indices of HIC showed a trend of an association with increased risk of metabolic syndrome (HICC-peptide odds ratio 1.13 [95% CI 0.97-1.31], P = 0.12, and HICISR 1.38 [0.88-2.17], P = 0.16) and impaired glucose metabolism (HICC-peptide 1.12 [0.92-1.36], P = 0.26, and HICISR 1.31 [0.74-2.33] P = 0.36), although point estimates reached no statistical significance. HIC was associated with different components of metabolic syndrome and markers of insulin secretion and insulin sensitivity. Decreased HIC may represent a novel pathophysiological mechanism of the metabolic syndrome, which may be used additionally for early identification of high-risk subjects.

  15. A prototype High Purity Germanium detector for high resolution gamma-ray spectroscopy at high count rates

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J., E-mail: rjcooper@lbl.gov [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Amman, M.; Luke, P.N. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Vetter, K. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Department of Nuclear Engineering, University of California, Berkeley, CA 94720 (United States)

    2015-09-21

    Where energy resolution is paramount, High Purity Germanium (HPGe) detectors continue to provide the optimum solution for gamma-ray detection and spectroscopy. Conventional large-volume HPGe detectors are typically limited to count rates on the order of ten thousand counts per second, however, limiting their effectiveness for high count rate applications. To address this limitation, we have developed a novel prototype HPGe detector designed to be capable of achieving fine energy resolution and high event throughput at count rates in excess of one million counts per second. We report here on the concept, design, and initial performance of the first prototype device.

  16. Clearance of technetium-99m-DTPA and HRCT findings in the evaluation of patients with Idiopathic Pulmonary Fibrosis

    Directory of Open Access Journals (Sweden)

    Karkavitsas Nikolaos

    2006-02-01

    Full Text Available Abstract Background Clearance of inhaled technetium-labeled diethylenetriamine pentaacetate (99mTc-DTPA is a marker of epithelial damage and an index of lung epithelial permeability. The aim of this study was to investigate the role of 99mTc-DTPA scan in patients with Idiopathic Pulmonary Fibrosis (IPF. Our hypothesis is that the rate of pulmonary 99mTc-DTPA clearance could be associated with extent of High Resolution Computed Tomography (HRCT abnormalities, cell differential of bronchoalveolar lavage fluid (BALF and pulmonary function tests (PFTs in patients with IPF. Methods We studied prospectively 18 patients (14 male, 4 female of median age 67yr (range 55–81 with histologically proven IPF. HRCT scoring included the mean values of extent of disease. Mean values of these percentages represented the Total Interstitial Disease Score (TID. DTPA clearance was analyzed according to a dynamic study using a Venticis II radioaerosol delivery system. Results The mean (SD TID score was 36 ± 12%, 3 patients had mild, 11 moderate and 4 severe TID. Abnormal DTPA clearance half-time (t1/2 Conclusion Our data suggest that 99mTc-DTPA lung scan is not well associated with HRCT abnormalities, PFTs, and BALF cellularity in patients with IPF. Further studies in large scale of patients are needed to define the role of this technique in pulmonary fibrosis.

  17. High interest rate policy in Turkey and factors influencing interest rate spreads

    Directory of Open Access Journals (Sweden)

    Funda Yurdakul

    2009-01-01

    Full Text Available The main purpose of this paper is to examine what factors explain the difference between effective interest rates of Turkey and USA. The paper considers seven variables explaining interest rate spread such as general prices, Gross Domestic Product (GDP, exchange rate, credibility index, level of international reserves, foreign trade deficit, and budget deficit. Four distinct periods were selected to explore the influences of the above mentioned variables on on interest rate spreads in these different time periods. The period covering 1994.1-2006:12 was splitted into three sub-periods: the sub-period covering 1994:1-1998:12, crisis period covering 1999:1-2001:.12, and post-crisis period covering 2002:1-2006.12. Employing the data for Turkey and applying Engle and Granger two-step procedure, this paper concludes that the only variable reducing interest rate spreads in all periods is GDP. The other variables generally increase the interest rate spreads.Engle and Granger estimation procedure, unit-root test, interest rate spreads, interest rate.

  18. High interest rate policy in Turkey and factors influencing interest rate spreads

    Directory of Open Access Journals (Sweden)

    Funda Yurdakul

    2009-01-01

    Full Text Available The main purpose of this paper is to examine what factors explain the difference between effective interest rates of Turkey and USA. The paper considers seven variables explaining interest rate spread such as general prices, Gross Domestic Product (GDP, exchange rate, credibility index, level of international reserves, foreign trade deficit, and budget deficit. Four distinct periods were selected to explore the influences of the above mentioned variables on on interest rate spreads in these different time periods. The period covering 1994.1-2006:12 was splitted into three sub-periods: the sub-period covering 1994:1-1998:12, crisis period covering 1999:1-2001:.12, and post-crisis period covering 2002:1-2006.12.                            Employing the data for Turkey and applying Engle and Granger two-step procedure, this paper concludes that the only variable reducing interest rate spreads in all periods is GDP. The other variables generally increase the interest rate spreads.Engle and Granger estimation procedure, unit-root test, interest rate spreads, interest rate.    

  19. CMOS pixel sensors on high resistive substrate for high-rate, high-radiation environments

    Science.gov (United States)

    Hirono, Toko; Barbero, Marlon; Breugnon, Patrick; Godiot, Stephanie; Gonella, Laura; Hemperek, Tomasz; Hügging, Fabian; Krüger, Hans; Liu, Jian; Pangaud, Patrick; Peric, Ivan; Pohl, David-Leon; Rozanov, Alexandre; Rymaszewski, Piotr; Wang, Anqing; Wermes, Norbert

    2016-09-01

    A depleted CMOS active pixel sensor (DMAPS) has been developed on a substrate with high resistivity in a high voltage process. High radiation tolerance and high time resolution can be expected because of the charge collection by drift. A prototype of DMAPS was fabricated in a 150 nm process by LFoundry. Two variants of the pixel layout were tested, and the measured depletion depths of the variants are 166 μm and 80 μm. We report the results obtained with the prototype fabricated in this technology.

  20. CMOS pixel sensors on high resistive substrate for high-rate, high-radiation environments

    Energy Technology Data Exchange (ETDEWEB)

    Hirono, Toko, E-mail: thirono@uni-bonn.de [Physikalisches Institute der Universität Bonn, Bonn (Germany); Barbero, Marlon; Breugnon, Patrick; Godiot, Stephanie [CPPM, Aix-Marseille Universite, CNRS/IN2P3, Marseille (France); Gonella, Laura; Hemperek, Tomasz; Hügging, Fabian; Krüger, Hans [Physikalisches Institute der Universität Bonn, Bonn (Germany); Liu, Jian; Pangaud, Patrick [CPPM, Aix-Marseille Universite, CNRS/IN2P3, Marseille (France); Peric, Ivan [IPE, Karlsruher Institut für Technologie, Karlsruhe (Germany); Pohl, David-Leon [Physikalisches Institute der Universität Bonn, Bonn (Germany); Rozanov, Alexandre [CPPM, Aix-Marseille Universite, CNRS/IN2P3, Marseille (France); Rymaszewski, Piotr [Physikalisches Institute der Universität Bonn, Bonn (Germany); Wang, Anqing [CPPM, Aix-Marseille Universite, CNRS/IN2P3, Marseille (France); Wermes, Norbert [Physikalisches Institute der Universität Bonn, Bonn (Germany)

    2016-09-21

    A depleted CMOS active pixel sensor (DMAPS) has been developed on a substrate with high resistivity in a high voltage process. High radiation tolerance and high time resolution can be expected because of the charge collection by drift. A prototype of DMAPS was fabricated in a 150 nm process by LFoundry. Two variants of the pixel layout were tested, and the measured depletion depths of the variants are 166 μm and 80 μm. We report the results obtained with the prototype fabricated in this technology.

  1. Improving mucociliary clearance in chronic obstructive pulmonary disease.

    Science.gov (United States)

    Bhowmik, Angshu; Chahal, Kamaljeet; Austin, Gillian; Chakravorty, Indranil

    2009-04-01

    Patients with COPD usually experience mucus hypersecretion as a result of airway inflammation and response to noxious stimuli. These in turn lead to worsening airway resistance, impaired airflow, increased work of breathing, dyspnoea and exercise intolerance. Mucus hypersecretion may also lead to increased exacerbations and poor health related quality of life (HRQL). Institution based pulmonary rehabilitation programs incorporating airway clearance techniques have been shown to improve HRQL, reduce dyspnoea and improve exercise tolerance but are often difficult to provide due to restricted accessibility and resource implications. This review examines the current evidence base and best clinical practice in the area of airway clearance. Mechanical devices such as the flutter valves, positive end expiratory pressure and high frequency chest wall oscillation (HFCWO) may be able to provide the benefits of improved airway clearance in the patient's home potentially with reduced demands on healthcare resources.

  2. Unsteady Tip Clearance Flow Pattern in an Isolated Axial Compressor Rotor with Micro Tip Injection

    Institute of Scientific and Technical Information of China (English)

    Shaojuan Geng; Hongwu Zhang; Jingyi Chen; Weiguang Huang

    2007-01-01

    A numerical study of the effect of discrete micro tip injection on unsteady tip clearance flow pattern in an isolated axial compressor rotor is presented, intending to better understand the flow mechanism behind stall control measures that act on tip clearance flow. Under the influence of injection the unsteadiness of self-induced tip clearance flow could be weakened. Also the radial migration of tip clearance vortex is confined to a smaller radial extent near the rotor tip and the trajectory of tip clearance flow is pushed more downstream. So the injection is beneficial to improve compressor stability and increase static pressure rise near rotor tip region. The results of injection with different injected mass flow rates show that for the special type of injector adopted in the paper the effect of injection on tip clearance flow may be different according to the relative strength between these two streams of flow. For a fixed injected mass flow rate, reducing the injector area to increase injection velocity can improve the effect of injection on tip clearance flow and thus the compressor stability. A comparison of calculations between single blade passage and multiple blade passages validates the utility of single passage computations to investigate the tip clearance flow for the case without injection and its interaction with injected flow for the case with tip injection.

  3. Absorptive clearance of DTPA as an aerosol-based biomarker in the cystic fibrosis airway

    Science.gov (United States)

    Corcoran, Timothy E; Thomas, Kristina M.; Myerburg, Michael M.; Muthukrishnan, Ashok; Weber, Lawrence; Frizzell, Raymond; Pilewski, Joseph M

    2010-01-01

    Biomarkers providing in vivo quantification of the basic elements of CF lung disease are needed. We questioned whether the absorption of a small, radiolabeled, hydrophilic molecule (Indium 111 DTPA) would be increased in CF airways. DTPA clearance has been used previously to assess epithelial permeability and may also be useful for quantifying liquid absorption. The absorptive clearance rate of DTPA was quantified in 10 CF and 11 control subjects using a novel aerosol technique. Subjects inhaled an aerosol containing non-absorbable Technetium-99m sulfur colloid (Tc-SC) particles and Indium-111 DTPA (In-DTPA). Tc-SC clearance from the lung is exclusively mucociliary while In-DTPA is cleared by both absorption and mucociliary clearance. The difference between the In-DTPA and Tc-SC clearance rates estimates In-DTPA absorption. Tc-SC (mucociliary) clearance was similar in central and peripheral zones in CF and non-CF. Total In-DTPA clearance was increased in both zones in CF. The absorptive component of In-DTPA clearance was increased in the airway-dominated central lung zones in CF (42 vs. 32 %/hr, p=0.03). The absorption of In-DTPA is increased in the CF airway. Further study is needed to understand the relative roles of fluid absorption, inflammation, and other mechanisms potentially affecting epithelial permeability and DTPA absorption. PMID:19717485

  4. Tensile Properties of TWIP Steel at High Strain Rate

    Institute of Scientific and Technical Information of China (English)

    XIONG Rong-gang; FU Ren-yu; SU Yu; LI Qian; WEI Xi-cheng; LI Lin

    2009-01-01

    Tensile tests of TWIP steels of two compositions are performed in the strain rate range of 10-5 -103 s-1.Results indicate that steel 1# does not exhibit TWIP effect but deformation-induced martensitic transformation appears only.There exists TWIP effect in steel 3#.Tensile properties at room temperature are sensitive to strain rate in the studied strain rate ranges.Analysis on the relationship between strain-hardening exponent and strain rates shows that strain-induced martensitic transformation and formation of twins during deformation have significant influence on their strain-hardening behavior.

  5. A forward error correction technique using a high-speed, high-rate single chip codec

    Science.gov (United States)

    Boyd, R. W.; Hartman, W. F.; Jones, Robert E.

    1989-01-01

    The authors describe an error-correction coding approach that allows operation in either burst or continuous modes at data rates of multiple hundreds of megabits per second. Bandspreading is low since the code rate is 7/8 or greater, which is consistent with high-rate link operation. The encoder, along with a hard-decision decoder, fits on a single application-specific integrated circuit (ASIC) chip. Soft-decision decoding is possible utilizing applique hardware in conjunction with the hard-decision decoder. Expected coding gain is a function of the application and is approximately 2.5 dB for hard-decision decoding at 10-5 bit-error rate with phase-shift-keying modulation and additive Gaussian white noise interference. The principal use envisioned for this technique is to achieve a modest amount of coding gain on high-data-rate, bandwidth-constrained channels. Data rates of up to 300 Mb/s can be accommodated by the codec chip. The major objective is burst-mode communications, where code words are composed of 32 n data bits followed by 32 overhead bits.

  6. Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades

    CERN Document Server

    Bittner, Bernhard; Kortner, Oliver; Kroha, Hubert; Manfredini, Alessandro; Nowak, Sebastian; Ott, Sebastian; Richter, Robert; Schwegler, Philipp; Zanzi, Daniele; Biebel, Otmar; Hertenberger, Ralf; Ruschke, Alexander; Zibell, Andre

    2016-01-01

    The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking e?ciency and spatial resolution at high counting rates will be achieved with ...

  7. Evaluation of circulating levels and renal clearance of natural amino acids in patients with Cushing's disease.

    Science.gov (United States)

    Faggiano, A; Pivonello, R; Melis, D; Alfieri, R; Filippella, M; Spagnuolo, G; Salvatore, F; Lombardi, G; Colao, A

    2002-02-01

    Although the hypercortisolism-induced impairment of protein homeostasis is object of several studies, a detailed evaluation of the complete amino acid profile of patients with Cushing's syndrome (CS) has never been performed. The aim of the current open transversal controlled study was to evaluate serum and urinary concentrations as well as renal clearance of the complete series of natural amino acids and their relationship with glucose tolerance in patients with Cushing's disease (CD). Twenty patients with CD (10 active and 10 cured) and 20 sex- and age-matched healthy controls entered the study. Measurement of serum and urinary levels of the complete series of natural amino acids was performed in all patients analyzed by cationic exchange high performance liquid cromatography (HPLC) after 2 weeks of a standardized protein intake regimen. The renal clearance (renal excretion rate) of each amino acid was calculated on the basis of the serum and urinary concentrations of creatinine and the specific amino acid. Fasting glucose and insulin levels, glucose and insulin response to standard glucose load, insulinogenic and homeostasis model insulin resistance (Homa-R) indexes were also evaluated and correlated to the circulating levels and renal clearances of each amino acid. Significantly higher serum (p<0.01) and urinary (p<0.05) levels of alanine and cystine, lower serum and higher urinary levels of leucine, isoleucine and valine (p<0.05) and higher renal excretion rates of leucine, isoleucine and valine (p<0.01) were found in patients with active CD than in patients cured from the disease and in controls. No difference was found between cured patients and controls. Creatinine clearance was similar in active and cured patients and in controls. In patients with active CD, urinary cortisol levels were significantly correlated to urinary cystine levels (r=0.85; p<0.01) and renal excretion rate of leucine (r=-0.76; p<0.05), isoleucine (r=-0.76; p<0.05) and valine (r=-0

  8. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  9. Renal clearance of pancreatic and salivary amylase relative to creatinine in patients with chronic renal insufficiency.

    Science.gov (United States)

    Keogh, J B; McGeeney, K F; Drury, M I; Counihan, T B; O'Donnell, M D

    1978-12-01

    Pancreatic and salivary amylase/creatinine clearance ratios in patients with various degrees of renal impairment were compared with those obtained for control subjects. In chronic renal insufficiency (mean GFR 30 ml/min +/- 15 SD; n = 13) the clearance ratios for pancreatic (mean 3.5 +/- 1.85 SD) and salivary (mean 2.3 +/- 1.3 SD) amylase were significantly higher (P less than 0.05) than those in controls. Corresponding control values (n = 26) were 2.64 +/- 0.86 (pancreatic) and 1.64 +/- 0.95 (salivary). Three patients showed values above the normal limit. In the diabetic group (mean GFR 41 ml/min +/- 22 SD; n = 10) salivary amylase/creatinine clearance ratios (mean 2.36 +/- 1.55 SD) were significantly higher than in controls (P less than 0.05). Three patients showed raised values. Pancreatic amylase clearance was raised in only one of these patients. Three patients with terminal disease (mean GFR 10 ml/min) showed markedly raised (two- to threefold) clearance ratios for both salivary and pancreatic amylase. Of a total of 26 patients, eight had increased total amylase/creatinine clearance ratios. Pancreatic amylase/creatinine clearance was increased in seven patients, while nine patients showed raised salivary amylase/creatinine ratios. Patients with raised clearance ratios did not have clinical evidence of pancreatitis. We suggest that, in the presence of impaired renal function, a high amylase/creatinine clearance ratio need not be indicative of pancreatic disease.

  10. Steady State Microbunching for High Brilliance and High Repetition Rate Storage Ring-Based Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Alex; Ratner, Daniel; /SLAC; Jiao, Yi; /Beijing, Inst. High Energy Phys.

    2012-09-06

    Electron-based light sources have proven to be effective sources of high brilliance, high frequency radiation. Such sources are typically either linac-Free Electron Laser (FEL) or storage ring types. The linac-FEL type has high brilliance (because the beam is microbunched) but low repetition rate. The storage ring type has high repetition rate (rapid beam circulation) but comparatively low brilliance or coherence. We propose to explore the feasibility of a microbunched beam in a storage ring that promises high repetition rate and high brilliance. The steady-state-micro-bunch (SSMB) beam in storage ring could provide CW sources for THz, EUV, or soft X-rays. Several SSMB mechanisms have been suggested recently, and in this report, we review a number of these SSMB concepts as promising directions for high brilliance, high repetition rate light sources of the future. The trick of SSMB lies in the RF system, together with the associated synchrotron beam dynamics, of the storage ring. Considering various different RF arrangements, there could be considered a number of scenarios of the SSMB. In this report, we arrange these scenarios more or less in order of the envisioned degree of technical challenge to the RF system, and not in the chronological order of their original references. Once the stored beam is steady-state microbunched in a storage ring, it passes through a radiator repeatedly every turn (or few turns). The radiator extracts a small fraction of the beam energy as coherent radiation with a wavelength corresponding to the microbunched period of the beam. In contrast to an FEL, this radiator is not needed to generate the microbunching (as required e.g. by SASE FELs or seeded FELs), so the radiator can be comparatively simple and short.

  11. Steady State Microbunching for High Brilliance and High Repetition Rate Storage Ring-Based Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Alex; Ratner, Daniel; /SLAC; Jiao, Yi; /Beijing, Inst. High Energy Phys.

    2012-09-06

    Electron-based light sources have proven to be effective sources of high brilliance, high frequency radiation. Such sources are typically either linac-Free Electron Laser (FEL) or storage ring types. The linac-FEL type has high brilliance (because the beam is microbunched) but low repetition rate. The storage ring type has high repetition rate (rapid beam circulation) but comparatively low brilliance or coherence. We propose to explore the feasibility of a microbunched beam in a storage ring that promises high repetition rate and high brilliance. The steady-state-micro-bunch (SSMB) beam in storage ring could provide CW sources for THz, EUV, or soft X-rays. Several SSMB mechanisms have been suggested recently, and in this report, we review a number of these SSMB concepts as promising directions for high brilliance, high repetition rate light sources of the future. The trick of SSMB lies in the RF system, together with the associated synchrotron beam dynamics, of the storage ring. Considering various different RF arrangements, there could be considered a number of scenarios of the SSMB. In this report, we arrange these scenarios more or less in order of the envisioned degree of technical challenge to the RF system, and not in the chronological order of their original references. Once the stored beam is steady-state microbunched in a storage ring, it passes through a radiator repeatedly every turn (or few turns). The radiator extracts a small fraction of the beam energy as coherent radiation with a wavelength corresponding to the microbunched period of the beam. In contrast to an FEL, this radiator is not needed to generate the microbunching (as required e.g. by SASE FELs or seeded FELs), so the radiator can be comparatively simple and short.

  12. TRP 9904 - Constitutive Behavior of High Strength Multiphase Sheel Steel Under High Strain Rate Deformation

    Energy Technology Data Exchange (ETDEWEB)

    David Matlock; John Speer

    2005-03-31

    The focus of the research project was to systematically assess the strain rate dependence of strengthening mechanisms in new advanced high strength sheet steels. Data were obtained on specially designed and produced Duel Phase and TRIP steels and compared to the properties of automotive steels currently in use.

  13. Tip Clearance Flows in Turbine Cascades

    Institute of Scientific and Technical Information of China (English)

    Li Wei; Qiao Weiyang; Sun Dawei

    2008-01-01

    This article describes the effects of some factors on the tip clearance flow in axial linear turbine cascades.The measurements of the total pressure loss coefficient are made at the cascade outlets by using a five-hole probe at exit Mach numbers of 0.10,0.14 and 0.19.At each exit Mach number,experiments axe performed at the tip clearance heights of 1.0%,1.5%,2.0%,2.5% and 3.0% of the blade height.The effects of the non-uniform tip clearance height of each blade in the pitchwise direction are also studied.The results show that at a given tip clearance height,generally,total pressure loss rises with exit Mach numbers proportionally.At a fixed exit Mach number,the total pressure loss augments nearly proportionally as the tip clearance height increases.The increased tip clearance heights in the tip regions of two adjacent blades are to be blame for the larger clearance loss of the center blade.Compared to the effects of the tip clearance height,the effects of the exit Mach number and the pitchwise variation of the tip clearance height on the cascade total pressure loss are so less significant to be omitted.

  14. Elastic clearance change in axisymmetric shearing process

    Science.gov (United States)

    Yoshida, Yoshinori

    2016-10-01

    An axisymmetric shearing experiment is conducted for a sheet of low carbon steel and stainless steel. Elastic change in the clearance between punch and die is measured. The increase of the clearance in shearing is confirmed and the influence of sheared material's flow stress on the clearance change is shown. Finite element analysis (FEA) of shearing with Gurson-Tvergaard-Needlman model (GTN model) is conducted for shearing of the carbon steels with rigid tools as a numerical experiment. Burr height is predicted in the FEA and the result is compared with the experimental result. In addition, the influence of the clearance on stress state in the material is investigated.

  15. How High Might the Revenue-maximizing Tax Rate Be?

    OpenAIRE

    Usher, Dan

    2014-01-01

    Through tax evasion, through the labour-leisure choice or in other ways, taxpayers reduce the tax base in response to an increase in the tax rate. The process is commonly-believed to generate a humped Laffer curve with a revenue-maximizing tax rate well short of 100%. That need not be so. In the “new tax responsiveness literature†, the revenue-maximizing tax rate is inferred from the observed “elasticity of taxable income†. It is shown in this article 1) that the inference is unwarran...

  16. Use of clearance rate in Choromytilus chorus (Bivalvia: Mytilidae as a non-destructive biomarker of aquatic pollution El uso de la tasa de aclaramiento en Choromytilus chorus (Bivalvia: Mytilidae como biomarcador no destructivo de la polución acuática

    Directory of Open Access Journals (Sweden)

    BEATRIZ TORO

    2003-06-01

    Full Text Available Reduction in clearance rate was observed in the mussel Choromytilus chorus in relation to the degree of environmental pollution. Three sampling sites included the polluted San Vicente Bay, middling polluted Corral Bay, and weakly polluted Yaldad Bay in southern Chile. Pollution levels were estimated by quantitative analysis of polynuclear aromatic hydrocarbons (PAHs in mussel tissue from the three sites. Mussels from San Vicente showed lowest clearance rates and highest PAHs levels in both spring 1998 and summer 1999. Populations from Corral and Yaldad showed generally low levels of PAHs, so the mussels from Yaldad showed the highest rates of clearance in comparison to Corral and San Vicente populations. The significant negative relationship (P Se observó un deterioro de la tasa de aclaramiento en Choromytilus chorus de acuerdo al grado de polución ambiental. Se incluyeron tres sitios de muestreos, la bahía de San Vicente muy contaminada, la bahía de Corral con una polución intermedia y la bahía de Yaldad, al sur de Chile, con una baja contaminación. Los niveles de polución fueron estimados por análisis cuantitativos de hidrocarburos aromáticos polinucleares (HAPs en el tejido de los choros zapatos de los tres sitios de muestreo. Los choros zapatos de San Vicente mostraron la menor tasa de aclaramiento y altos niveles de HAPs, tanto en la primavera de 1998 como en el verano de 1999. Las poblaciones de Corral y Yaldad mostraron en general bajos niveles de HAPs, en tanto que los ejemplares de Yaldad presentaron altas tasas de aclaramiento en comparación con las poblaciones de Corral y San Vicente. La relación negativa significativa (P < 0,001 entre la polución en el tejido de los choros zapatos y sus tasas de aclaramiento, argumenta la utilidad del método como un biomarcador no destructivo para evaluar el impacto ambiental de la polución en las especies marinas

  17. Three-Dimensional Printable High-Temperature and High-Rate Heaters.

    Science.gov (United States)

    Yao, Yonggang; Fu, Kun Kelvin; Yan, Chaoyi; Dai, Jiaqi; Chen, Yanan; Wang, Yibo; Zhang, Bilun; Hitz, Emily; Hu, Liangbing

    2016-05-24

    High temperature heaters are ubiquitously used in materials synthesis and device processing. In this work, we developed three-dimensional (3D) printed reduced graphene oxide (RGO)-based heaters to function as high-performance thermal supply with high temperature and ultrafast heating rate. Compared with other heating sources, such as furnace, laser, and infrared radiation, the 3D printed heaters demonstrated in this work have the following distinct advantages: (1) the RGO based heater can operate at high temperature up to 3000 K because of using the high temperature-sustainable carbon material; (2) the heater temperature can be ramped up and down with extremely fast rates, up to ∼20 000 K/second; (3) heaters with different shapes can be directly printed with small sizes and onto different substrates to enable heating anywhere. The 3D printable RGO heaters can be applied to a wide range of nanomanufacturing when precise temperature control in time, placement, and the ramping rate are important.

  18. Development of a cryogenic hydrogen microjet for high-intensity, high-repetition rate experiments

    Science.gov (United States)

    Kim, J. B.; Göde, S.; Glenzer, S. H.

    2016-11-01

    The advent of high-intensity, high-repetition-rate lasers has led to the need for replenishing targets of interest for high energy density sciences. We describe the design and characterization of a cryogenic microjet source, which can deliver a continuous stream of liquid hydrogen with a diameter of a few microns. The jet has been imaged at 1 μm resolution by shadowgraphy with a short pulse laser. The pointing stability has been measured at well below a mrad, for a stable free-standing filament of solid-density hydrogen.

  19. A High Power and High Repetition Rate Modelocked Ti-Sapphire Laser for Photoinjectors

    Energy Technology Data Exchange (ETDEWEB)

    J. Hansknecht; M. Poelker

    2001-07-01

    A high power cw mode-locked Ti-sapphire laser has been constructed to drive the Jefferson Lab polarized photoinjector and provide > 500 mW average power with 50 ps pulsewidths at 499 MHz or 1497 MHz pulse repetition rates. This laser allows efficient, high current synchronous photoinjection for extended periods of time before intrusive steps must be taken to restore the quantum efficiency of the strained layer GaAs photocathode. The use of this laser has greatly enhanced the maximum high polarization beam current capability and operating lifetime of the Jefferson Lab photoinjector compared with previous performance using diode laser systems. A novel modelocking technique provides a simple means to phase-lock the optical pulse train of the laser to the accelerator and allows for operation at higher pulse repetition rates to {approx} 3 GHz without modification of the laser cavity. The laser design and characteristics are described below.

  20. Mechanical Behavior of MTMoCr under High Temperature and High Strain-rate

    Directory of Open Access Journals (Sweden)

    Zhengwei Dong

    2013-02-01

    Full Text Available MTMoCr is a kind of Mo-Cr alloy cast iron often used to make automobile panel dies. To study high-speed machining process of automobile panel dies, the material’s elastic modulus and rupture critical values of MTMoCr at 20℃-800℃ were studied based on the high temperature elongation test. The material’s stress-strain diagram at various temperatures set-points (20℃-500℃ and various strain-rates (500/s-5000/s were studied and the dynamic tensile yield strength values were obtained by dynamic SHPB (Split Hopkinson Pressure Bar high-speed compression test. The experimental results indicate that MTMoCr has heat resistance and its behavior is between toughness and brittleness materials. Its toughness is enhanced with temperature increasing. The strain-rate strengthening effect prevails over temperature softening effect.