WorldWideScience

Sample records for high airflow rates

  1. FURTHER STUDIES ON THE VARIATION OF SPRAY DEPOSITS IN VINEYARDS WITH AIRFLOW RATE AND VOLUME RATE

    Directory of Open Access Journals (Sweden)

    Emanuele Cerruto

    2007-03-01

    Full Text Available The present research, continuing that reported in [2], deals with the spray application subject, so to investigate as volume rate and airflow rate, forward speed being equal, affect the foliar deposition in an espalier vineyard. Experimental trials were carried out by means of an air assisted towed sprayer, equipped with “Albuz ATR” nozzles. To take into account the influence of the development of the trees, the field trials were replicated in two phenological stages with an interval of about one month: “Inflorescences fully developed” (stage 1 and “Beginning of berry touch” (stage 2. A full factorial experiment was carried out for each growth stage, with two airflow rates (3.9 and 7.5 m3/s, three volume rates (103, 216, and 276 L/ha in the first growth stage and 154, 330 and 432 L/ha in the second growth stage, and four replicates, arranged according to a randomised complete block design. Working pressure (1.2 MPa and forward speed (1.4 m/s were kept unchanged for all the trials. The foliar deposition was measured by means of a spectrophotometric technique. The leaves were sampled on two depth layers and two or three heights, according to the trees’ development. The results showed that volume rate did not significantly influence the mean foliar deposition in both the two growth stages, while the highest deposits were obtained with the lowest airflow rate. The airflow rate × volume rate interaction, though not statistically significant, showed that low volume rates together with high airflow rates, result in a noticeable reduction in foliar deposition (29% with respect the grand mean, due to an increase of the spry drift, especially at the first growth stage, when the foliar development is little. These second tests, unlike those described in [2], did not show any positive influence of the airflow rate on the foliar deposition in the inner part of the canopy, so further investigations could be necessary to better understand the

  2. Influence of Airflow on Laboratory Storage of High Moisture Corn Stover

    Energy Technology Data Exchange (ETDEWEB)

    Lynn M. Wendt; Ian J. Bonner; Amber N. Hoover; Rachel M. Emerson; William A. Smith

    2014-04-01

    Storing high moisture biomass for bioenergy use is a reality in many areas of the country where wet harvest conditions and environmental factors prevent dry storage from being feasible. Aerobic storage of high moisture biomass leads to microbial degradation and self-heating, but oxygen limitation can aid in material preservation. To understand the influence of oxygen presence on high moisture biomass (50 %, wet basis), three airflow rates were tested on corn stover stored in laboratory reactors. Temperature, carbon dioxide production, dry matter loss, chemical composition, fungal abundance, pH, and organic acids were used to monitor the effects of airflow on storage conditions. The results of this work indicate that oxygen availability impacts both the duration of self-heating and the severity of dry matter loss. High airflow systems experienced the greatest initial rates of loss but a shortened microbially active period that limited total dry matter loss (19 %). Intermediate airflow had improved preservation in short-term storage compared to high airflow systems but accumulated the greatest dry matter loss over time (up to 27 %) as a result of an extended microbially active period. Low airflow systems displayed the best performance with the lowest rates of loss and total loss (10 %) in storage at 50 days. Total structural sugar levels of the stored material were preserved, although glucan enrichment and xylan loss were documented in the high and intermediate flow conditions. By understanding the role of oxygen availability on biomass storage performance, the requirements for high moisture storage solutions may begin to be experimentally defined.

  3. Effects of mass airflow rate through an open-circuit gas quantification system when measuring carbon emissions.

    Science.gov (United States)

    Gunter, Stacey A; Bradford, James A; Moffet, Corey A

    2017-01-01

    Methane (CH) and carbon dioxide (CO) represent 11 and 81%, respectively, of all anthropogenic greenhouse gas emissions. Agricultural CH emissions account for approximately 43% of all anthropogenic CH emissions. Most agricultural CH emissions are attributed to enteric fermentation within ruminant livestock; hence, the heightened interest in quantifying and mitigating this source. The automated, open-circuit gas quantification system (GQS; GreenFeed, C-Lock, Inc., Rapid City, SD) evaluated here can be placed in a pasture with grazing cattle and can measure their CH and CO emissions with spot sampling. However, improper management of the GQS can have an erroneous effect on emission estimates. One factor affecting the quality of emission estimates is the airflow rates through the GQS to ensure a complete capture of the breath cloud emitted by the animal. It is hypothesized that at lower airflow rates this cloud will be incompletely captured. To evaluate the effect of airflow rate through the GQS on emission estimates, a data set was evaluated with 758 CO and CH emission estimates with a range in airflows of 10.7 to 36.6 L/s. When airflow through the GQS was between 26.0 and 36.6 L/s, CO and CH emission estimates were not affected ( = 0.14 and 0.05, respectively). When airflow rates were less than 26.0 L/s, CO and CH emission estimates were lower and decreased as airflow rate decreased ( emissions are underestimated. Maintaining mass airflow through a GQS at rates greater than 26 L/s is important for producing high quality CO and CH emission estimates.

  4. Definition of airflow rate induced by polifractional materials

    Science.gov (United States)

    Popov, E. N.

    2018-03-01

    This paper deals with further analysis of a probabilistic and statistical approach to determine the aerodynamic drag coefficient of particles in a flow of free-falling polifractional material. It also describes the experimental assembly enabling one to determine airflow rate induced by polifractional material and provides comparison of analytical calculations with experimental data.

  5. Investigation on the effect of blending ratio and airflow rate on syngas profile produced from co-gasification of blended feedstock

    Directory of Open Access Journals (Sweden)

    Inayat Muddasser

    2017-01-01

    Full Text Available Shortages of feedstock supply due to seasonal availability, high transportation costs, and lack of biomass market are creating serious problems in continues operation of bioenergy industry. Aiming at this problem, utilization of blended feedstock is proposed. In this work blends of two different biomasses (wood and coconut shells were co-gasified using externally heated downdraft gasifier. The effects of varying biomass blending ratio and airflow rate on gaseous components of syngas and its heating value were investigated. The results obtained from the experiments revealed that W20:CS80 blend yielded higher values for H2 (20 Vol.% and HHV (18 MJ/Nm3 as compared to the other blends. The higher airflow rate has a negative effect on syngas profile and heating value. The CO and CH4 were observed higher at the start of the process, however, CO was observed decreasing afterward, and the CH4 dropped to 5.0 Vol.%. The maximum H2 and CH4 were obtained at 2.5 LPM airflow rate. The process was noticed more stable at low air flow rates. The HHV was observed higher at the start of process at low airflow rate. It is concluded that low airflow rate and a higher ratio of coconut shells can improve the syngas quality during co-gasification.

  6. The effect of airflow rates and aeration mode on the respiration activity of four organic wastes: Implications on the composting process.

    Science.gov (United States)

    Mejias, Laura; Komilis, Dimitrios; Gea, Teresa; Sánchez, Antoni

    2017-07-01

    The aim of this study was to assess the effect of the airflow and of the aeration mode on the composting process of non-urban organic wastes that are found in large quantities worldwide, namely: (i) a fresh, non-digested, sewage sludge (FSS), (ii) an anaerobically digested sewage sludge (ADSS), (iii) cow manure (CM) and (iv) pig sludge (PS). This assessment was done using respirometric indices. Two aeration modes were tested, namely: (a) a constant air flowrate set at three different initial fixed airflow rates, and (b) an oxygen uptake rate (OUR)-controlled airflow rate. The four wastes displayed the same behaviour namely a limited biological activity at low aeration, while, beyond a threshold value, the increase of the airflow did not significantly increase the dynamic respiration indices (DRI 1 max , DRI 24 max and AT 4 ). The threshold airflow rate varied among wastes and ranged from 42NL air kg -1 DMh -1 for CM and from 67 to 77NL air kg -1 DMh -1 for FSS, ADSS and PS. Comparing the two aeration modes tested (constant air flow, OUR controlled air flow), no statistically significant differences were calculated between the respiration activity indices obtained at those two aeration modes. The results can be considered representative for urban and non-urban organic wastes and establish a general procedure to measure the respiration activity without limitations by airflow. This will permit other researchers to provide consistent results during the measurement of the respiration activity. Results indicate that high airflows are not required to establish the maximum respiration activity. This can result in energy savings and the prevention of off-gas treatment problems due to the excessive aeration rate in full scale composting plants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Investigation of non-uniform airflow signal oscillation during high frequency chest compression

    Directory of Open Access Journals (Sweden)

    Lee Jongwon

    2005-05-01

    Full Text Available Abstract Background High frequency chest compression (HFCC is a useful and popular therapy for clearing bronchial airways of excessive or thicker mucus. Our observation of respiratory airflow of a subject during use of HFCC showed the airflow oscillation by HFCC was strongly influenced by the nonlinearity of the respiratory system. We used a computational model-based approach to analyse the respiratory airflow during use of HFCC. Methods The computational model, which is based on previous physiological studies and represented by an electrical circuit analogue, was used for simulation of in vivo protocol that shows the nonlinearity of the respiratory system. Besides, airflow was measured during use of HFCC. We compared the simulation results to either the measured data or the previous research, to understand and explain the observations. Results and discussion We could observe two important phenomena during respiration pertaining to the airflow signal oscillation generated by HFCC. The amplitudes of HFCC airflow signals varied depending on spontaneous airflow signals. We used the simulation results to investigate how the nonlinearity of airway resistance, lung capacitance, and inertance of air characterized the respiratory airflow. The simulation results indicated that lung capacitance or the inertance of air is also not a factor in the non-uniformity of HFCC airflow signals. Although not perfect, our circuit analogue model allows us to effectively simulate the nonlinear characteristics of the respiratory system. Conclusion We found that the amplitudes of HFCC airflow signals behave as a function of spontaneous airflow signals. This is due to the nonlinearity of the respiratory system, particularly variations in airway resistance.

  8. Measuring OutdoorAir Intake Rates Using Electronic Velocity Sensors at Louvers and Downstream of Airflow Straighteners

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William; Sullivan, Douglas; Cohen, Sebastian; Han, Hwataik

    2008-10-01

    Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100percent, and were often greater than 25percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

  9. Influence of airflow rate and substrate nature on heterogeneous struvite precipitation.

    Science.gov (United States)

    Saidou, H; Ben Moussa, S; Ben Amor, M

    2009-01-01

    In wastewater treatment plants a hard scale consisting of struvite crystals can be formed, in pipes and recirculation pumps, during anaerobic digestion of wastewater. This study was conducted to evaluate the effect of airflow rate and substrate nature on nucleation type, induction period and supersaturation coefficient during struvite precipitation. A crystallization reactor similar to that designed for calcium carbonate precipitation was used. The pH of synthetic wastewater solution was increased by air bubbling. Experimental results indicated that the airflow increased heterogeneous precipitation of struvite. The susceptibility to scale formation was more important on polyamide and polyvinyl chloride than on stainless steel. In all cases, X-ray diffraction and infrared spectroscopy showed that the precipitated solid phase was solely struvite. No difference in crystal morphology was observed. However, at similar experimental conditions, the particle size of struvite was higher for stainless-steel material than that for plastic materials.

  10. Minimum airflow reset of single-duct VAV terminal boxes

    Science.gov (United States)

    Cho, Young-Hum

    Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and

  11. Investigation of airflow patterns in a microclimate by particle image velocimetry (PIV)

    DEFF Research Database (Denmark)

    Mortensen, Lone Hedegaard; Rode, Carsten; Peuhkuri, Ruut

    2008-01-01

    Problems with mould growth in dwellings usually occur in bedrooms in the microclimate behind closets placed next to exterior walls with poor insulation. It is anticipated that the problems are caused by lack of airflow behind the furniture in combination with a colder surface temperature and a high...... that the flow rates behind the furniture will increase with increased distance between the closet and the wall, and even higher airflow rates are seen when the furniture is elevated by legs....

  12. Sleep position and the ocular surface in a high airflow environment

    Directory of Open Access Journals (Sweden)

    Vinod Gauba, FRCOphth

    2014-01-01

    Full Text Available Purpose: To study the relationship between sleep position and ocular surface symptoms and signs in an high air flow environment. Methods: Prospective observational study of new patients attending the dry eye clinic was performed. Patients with pre-existing ocular history, relevant systemic history (e.g. Sjogren’s syndrome or who were using topical or systemic therapy for dry eye were not included. Data were collected from the patient to document their dry eye symptoms; preferred dependent sleeping side and their bedroom airflow. All patients were examined by a clinician blind to the patient’s responses where Schirmer’s test and slit lamp examination were performed looking for the presence of lagophthalmos and corneal epitheliopathy. Results: 48 patients enrolled into the study of which 23 were males and 25 were females with a normal and comparable age distribution. The study found a strong association between patients’ preferred sleeping side and the incidence of corneal epitheliopathy in the contralateral eye particularly in patients with evidence of lagophthalmos. Dry eye symptoms were found to be worse and tear production lower on the contralateral side to the preferred sleeping side particularly in patients who sleep in a high airflow environment. Conclusion: In patients sleeping in a high airflow environment with nocturnal lagophthalmos, this study observed an association between preferred dependent sleep position and increased dry eye symptoms, lower Schirmer’s scores and increased corneal epitheliopathy in the contralateral eye. Keywords: Sleep, Dry eyes, Lagophthalmos, Epiphora

  13. Airflow Simulation Techniques

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The paper describes the development in airflow simulations in rooms . The research is, as other areas of flow research, influenced by the decreasing cost of computation which seems to indicate an increased use of airflow simulation in the coming years.......The paper describes the development in airflow simulations in rooms . The research is, as other areas of flow research, influenced by the decreasing cost of computation which seems to indicate an increased use of airflow simulation in the coming years....

  14. Behavior of HEPA filters under high humidity airflows

    International Nuclear Information System (INIS)

    Ricketts, C.I.

    1992-10-01

    To help determine and improve the safety margins of High Efficiency Particulate Air (HEPA) filter units in nuclear facilities under possible accident conditions, the structural limits and failure mechanisms of filter in high-humidity airflows were established and the fundamental physical phenomena underlying filter failure or malfunction in humid air were identified. Empirical models for increases in filter pressure drop with time in terms of the relevant airstream parameters were also developed. The weaknesses of currently employed humidity countermeasures used in filter protection are discussed and fundamental explanations for reported filter failures in normal service are given. (orig./DG) [de

  15. Visualization of airflow growing soap bubbles

    Science.gov (United States)

    Al Rahbi, Hamood; Bock, Matthew; Ryu, Sangjin

    2016-11-01

    Visualizing airflow inside growing soap bubbles can answer questions regarding the fluid dynamics of soap bubble blowing, which is a model system for flows with a gas-liquid-gas interface. Also, understanding the soap bubble blowing process is practical because it can contribute to controlling industrial processes similar to soap bubble blowing. In this study, we visualized airflow which grows soap bubbles using the smoke wire technique to understand how airflow blows soap bubbles. The soap bubble blower setup was built to mimic the human blowing process of soap bubbles, which consists of a blower, a nozzle and a bubble ring. The smoke wire was placed between the nozzle and the bubble ring, and smoke-visualized airflow was captured using a high speed camera. Our visualization shows how air jet flows into the growing soap bubble on the ring and how the airflow interacts with the soap film of growing bubble.

  16. Experimental Research on Optimizing Inlet Airflow of Wet Cooling Towers under Crosswind Conditions

    Science.gov (United States)

    Chen, You Liang; Shi, Yong Feng; Hao, Jian Gang; Chang, Hao; Sun, Feng Zhong

    2018-01-01

    A new approach of installing air deflectors around tower inlet circumferentially was proposed to optimize the inlet airflow and reduce the adverse effect of crosswinds on the thermal performance of natural draft wet cooling towers (NDWCT). And inlet airflow uniformity coefficient was defined to analyze the uniformity of circumferential inlet airflow quantitatively. Then the effect of air deflectors on the NDWCT performance was investigated experimentally. By contrast between inlet air flow rate and cooling efficiency, it has been found that crosswinds not only decrease the inlet air flow rate, but also reduce the uniformity of inlet airflow, which reduce NDWCT performance jointly. After installing air deflectors, the inlet air flow rate and uniformity coefficient increase, the uniformity of heat and mass transfer increases correspondingly, which improve the cooling performance. In addition, analysis on Lewis factor demonstrates that the inlet airflow optimization has more enhancement of heat transfer than mass transfer, but leads to more water evaporation loss.

  17. Occupational Exposures and Chronic Airflow Limitation

    Directory of Open Access Journals (Sweden)

    Helen Dimich-Ward

    1996-01-01

    Full Text Available The recent literature was reviewed to evaluate whether chronic airflow limitation is associated with occupational exposures to dusts. Only those studies that controlled for the effects of smoking were included. There is compelling evidence that exposure to inorganic dusts, such as from coal and hardrock mining or asbestos, are associated with the development of chronic airflow limitation, independently of pneumoconiosis. Nonsmoking gold miners are particularly at high risk of airflow obstruction and emphysema. Findings from studies of organic dusts, such as exposures to wood, cotton, grain or other agricultural dusts, or to mixed dust exposures, were less consistent but tended to show positive dose-response associations. In the majority of studies, no statistical interaction was shown between dust exposures and smoking; however, the effects of the dust exposures were often more pronounced. An occupational history should be considered, in addition to a smoking history, as an integral part of an investigation of chronic airflow limitation in a patient.

  18. Computational fluid dynamics study on the influence of airflow patterns on carbon dioxide distribution in a scaled livestock building

    DEFF Research Database (Denmark)

    Rong, Li; Nielsen, P V; Tong, G

    2008-01-01

    building with slatted floor. Contaminant sources are assumed to be modelled as a constant concentration on the manure surface. Three different ventilation rates and two different deflector degrees are studied, in which the deflector is applied to change the airflow patterns. A CFD commercial software code......Airflow patterns and airflow rate have an important influence on contaminant distribution in livestock buildings. The objective of this paper is to model and evaluate the effect of airflow rates and airflow patterns effect on CO2 concentration distribution and emission rates in a scaled livestock...

  19. Experimental study on the characterization of airflow effect on the direct methanol fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Kuan, Yean-Der [Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology, Taichung (China); Lee, Shi-Min [Department of Aerospace Engineering, Tamkang University, Taipei (China); Sung, Min-Feng [Department of Mechanical and Electromechanical Engineering, Tamkang University, Taipei (China)

    2009-08-15

    The PCB manufacturing process has been applied to the DMFC package which is especially suitable for the planar type DMFC module design. Maintaining the planar DMFC in good operating condition is an important task. This paper discusses the cathode airflow effect on the single cell and also on the 3-cell planar DMFC module. In the single cell study, the research starts from the airflow rate to airflow velocity viewpoint. In the DMFC module study, a 3-cell DMFC module, a substitute of 3-Cell PCB DMFC module, with a parallel flow board are compared. The results indicate that providing suitable cathode airflow velocity is more important than merely considering the airflow rate in the DMFC single or 3-cell DMFC module. (author)

  20. Experimental study on airflow fluctuation characteristic of an underfloor air supply terminal unit

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinping [School of Electric Power, South China University of Technology, Guangzhou 510640 (China); State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510640 (China); Wu, Yanfang [Design Institute of Guangzhou Metro Corporation, Guangzhou 510010 (China)

    2010-11-15

    In order to investigate dynamic characteristic of underfloor air supply terminal unit, an IFV900A hot-wire anemometer was used to measure the corresponding velocity field. Turbulence intensity and power spectrum density exponent of air velocity signal were analyzed. The result showed that the outlet velocity distribution of underfloor air supply terminal unit was uniform. With increment of height, the velocity distribution trends to be uniform. Two velocity attenuation regions appear during airflow development. Turbulence intensity changes obviously with height. It is lower than that of mechanical wind. Turbulence intensity goes up with the increment of jetting distance. Power spectrum density exponent trends to the value of natural wind with increase of jetting distance and decrease of wind velocity. The exponent value approaches to the value of typical natural wind for the air velocity is 0.5 m/s under high supply air rate. With airflow diffusion, the fluctuation characteristic of airflow varies obviously with the jetting direction. The fluctuation characteristic of airflow changes to that of natural wind with the increase of height which can improve comfort of indoor environment. (author)

  1. Characterization of the Airflow from a Bottom Hung Window under Natural Ventilation

    DEFF Research Database (Denmark)

    Svidt, Kjeld; Heiselberg, Per; Nielsen, Peter V.

    This paper describes the results of laboratory measurements of the airflow from a bottom hung window mounted near the ceiling of a ventilated room. In the laboratory set-up it was possible to control the temperature difference and the airflow rate through the window. The pressure drop through...

  2. Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows.

    Science.gov (United States)

    Schreur, H J; Sterk, P J; Vanderschoot, J; van Klink, H C; van Vollenhoven, E; Dijkman, J H

    1992-01-01

    BACKGROUND: A common auscultatory finding in pulmonary emphysema is a reduction of lung sounds. This might be due to a reduction in the generation of sounds due to the accompanying airflow limitation or to poor transmission of sounds due to destruction of parenchyma. Lung sound intensity was investigated in normal and emphysematous subjects in relation to airflow. METHODS: Eight normal men (45-63 years, FEV1 79-126% predicted) and nine men with severe emphysema (50-70 years, FEV1 14-63% predicted) participated in the study. Emphysema was diagnosed according to pulmonary history, results of lung function tests, and radiographic criteria. All subjects underwent phonopneumography during standardised breathing manoeuvres between 0.5 and 2 1 below total lung capacity with inspiratory and expiratory target airflows of 2 and 1 l/s respectively during 50 seconds. The synchronous measurements included airflow at the mouth and lung volume changes, and lung sounds at four locations on the right chest wall. For each microphone airflow dependent power spectra were computed by using fast Fourier transformation. Lung sound intensity was expressed as log power (in dB) at 200 Hz at inspiratory flow rates of 1 and 2 l/s and at an expiratory flow rate of 1 l/s. RESULTS: Lung sound intensity was well repeatable on two separate days, the intraclass correlation coefficient ranging from 0.77 to 0.94 between the four microphones. The intensity was strongly influenced by microphone location and airflow. There was, however, no significant difference in lung sound intensity at any flow rate between the normal and the emphysema group. CONCLUSION: Airflow standardised lung sound intensity does not differ between normal and emphysematous subjects. This suggests that the auscultatory finding of diminished breath sounds during the regular physical examination in patients with emphysema is due predominantly to airflow limitation. Images PMID:1440459

  3. Airflow and radon transport modeling in four large buildings

    International Nuclear Information System (INIS)

    Fan, J.B.; Persily, A.K.

    1995-01-01

    Computer simulations of multizone airflow and contaminant transport were performed in four large buildings using the program CONTAM88. This paper describes the physical characteristics of the buildings and their idealizations as multizone building airflow systems. These buildings include a twelve-story multifamily residential building, a five-story mechanically ventilated office building with an atrium, a seven-story mechanically ventilated office building with an underground parking garage, and a one-story school building. The air change rates and interzonal airflows of these buildings are predicted for a range of wind speeds, indoor-outdoor temperature differences, and percentages of outdoor air intake in the supply air Simulations of radon transport were also performed in the buildings to investigate the effects of indoor-outdoor temperature difference and wind speed on indoor radon concentrations

  4. Underground anemotactic orientation in leaf-cutting ants: perception of airflow and experience-dependent choice of airflow direction during digging

    Science.gov (United States)

    Halboth, Florian; Roces, Flavio

    2017-10-01

    Air exchange between the large nests of Atta vollenweideri leaf-cutting ants and the environment strongly relies on a passive, wind-induced ventilation mechanism. Air moves through nest tunnels and airflow direction depends on the location of the tunnel openings on the nest mound. We hypothesized that ants might use the direction of airflow along nest tunnels as orientation cue in the context of climate control, as digging workers might prefer to broaden or to close tunnels with inflowing or outflowing air in order to regulate nest ventilation. To investigate anemotactic orientation in Atta vollenweideri, we first tested the ants' ability to perceive air movements by confronting single workers with airflow stimuli in the range 0 to 20 cm/s. Workers responded to airflow velocities ≥ 2 cm/s, and the number of ants reacting to the stimulus increased with increasing airflow speed. Second, we asked whether digging workers use airflow direction as an orientation cue. Workers were exposed to either inflow or outflow of air while digging in the nest and could subsequently choose between two digging sites providing either inflow or outflow of air, respectively. Workers significantly chose the side with the same airflow direction they experienced before. When no airflow was present during initial digging, workers showed no preference for airflow directions. Workers developed preferences for airflow direction only after previous exposure to a given airflow direction. We suggest that experience-modified anemotaxis might help leaf-cutting ants spatially organize their digging activity inside the nest during tasks related to climate control.

  5. New CFD tools to evaluate nasal airflow.

    Science.gov (United States)

    Burgos, M A; Sanmiguel-Rojas, E; Del Pino, C; Sevilla-García, M A; Esteban-Ortega, F

    2017-08-01

    Computational fluid dynamics (CFD) is a mathematical tool to analyse airflow. As currently CFD is not a usual tool for rhinologists, a group of engineers in collaboration with experts in Rhinology have developed a very intuitive CFD software. The program MECOMLAND ® only required snapshots from the patient's cross-sectional (tomographic) images, being the output those results originated by CFD, such as airflow distributions, velocity profiles, pressure, temperature, or wall shear stress. This is useful complementary information to cover diagnosis, prognosis, or follow-up of nasal pathologies based on quantitative magnitudes linked to airflow. In addition, the user-friendly environment NOSELAND ® helps the medical assessment significantly in the post-processing phase with dynamic reports using a 3D endoscopic view. Specialists in Rhinology have been asked for a more intuitive, simple, powerful CFD software to offer more quality and precision in their work to evaluate the nasal airflow. We present MECOMLAND ® and NOSELAND ® which have all the expected characteristics to fulfil this demand and offer a proper assessment with the maximum of quality plus safety for the patient. These programs represent a non-invasive, low-cost (as the CT scan is already performed in every patient) alternative for the functional study of the difficult rhinologic case. To validate the software, we studied two groups of patients from the Ear Nose Throat clinic, a first group with normal noses and a second group presenting septal deviations. Wall shear stresses are lower in the cases of normal noses in comparison with those for septal deviation. Besides, velocity field distributions, pressure drop between nasopharynx and the ambient, and flow rates in each nostril were different among the nasal cavities in the two groups. These software modules open up a promising future to simulate the nasal airflow behaviour in virtual surgery intervention scenarios under different pressure or

  6. Pitot-tube flowmeter for quantification of airflow during sleep

    International Nuclear Information System (INIS)

    Kirkness, J P; McGinley, B M; Schwartz, A R; Smith, P L; Patil, S P; Schneider, H; Verma, M; Wheatley, J R; Amis, T C; Erlacher, M

    2011-01-01

    The gold-standard pneumotachograph is not routinely used to quantify airflow during overnight polysomnography due to the size, weight, bulkiness and discomfort of the equipment that must be worn. To overcome these deficiencies that have precluded the use of a pneumotachograph in routine sleep studies, our group developed a lightweight, low dead space 'pitot flowmeter' (based on pitot-tube principle) for use during sleep. We aimed to examine the characteristics and validate the flowmeter for quantifying airflow and detecting hypopneas during polysomnography by performing a head-to-head comparison with a pneumotachograph. Four experimental paradigms were utilized to determine the technical performance characteristics and the clinical usefulness of the pitot flowmeter in a head-to-head comparison with a pneumotachograph. In each study (1–4), the pitot flowmeter was connected in series with a pneumotachograph under either static flow (flow generator inline or on a face model) or dynamic flow (subject breathing via a polyester face model or on a nasal mask) conditions. The technical characteristics of the pitot flowmeter showed that, (1) the airflow resistance ranged from 0.065 ± 0.002 to 0.279 ± 0.004 cm H 2 O L –1 s –1 over the airflow rates of 10 to 50 L min −1 . (2) On the polyester face model there was a linear relationship between airflow as measured by the pitot flowmeter output voltage and the calibrated pneumtachograph signal a (β 1 = 1.08 V L −1 s −1 ; β 0 = 2.45 V). The clinically relevant performance characteristics (hypopnea detection) showed that (3) when the pitot flowmeter was connected via a mask to the human face model, both the sensitivity and specificity for detecting a 50% decrease in peak-to-peak airflow amplitude was 99.2%. When tested in sleeping human subjects, (4) the pitot flowmeter signal displayed 94.5% sensitivity and 91.5% specificity for the detection of 50% peak-to-peak reductions in pneumotachograph

  7. Pitot-tube flowmeter for quantification of airflow during sleep.

    Science.gov (United States)

    Kirkness, J P; Verma, M; McGinley, B M; Erlacher, M; Schwartz, A R; Smith, P L; Wheatley, J R; Patil, S P; Amis, T C; Schneider, H

    2011-02-01

    The gold-standard pneumotachograph is not routinely used to quantify airflow during overnight polysomnography due to the size, weight, bulkiness and discomfort of the equipment that must be worn. To overcome these deficiencies that have precluded the use of a pneumotachograph in routine sleep studies, our group developed a lightweight, low dead space 'pitot flowmeter' (based on pitot-tube principle) for use during sleep. We aimed to examine the characteristics and validate the flowmeter for quantifying airflow and detecting hypopneas during polysomnography by performing a head-to-head comparison with a pneumotachograph. Four experimental paradigms were utilized to determine the technical performance characteristics and the clinical usefulness of the pitot flowmeter in a head-to-head comparison with a pneumotachograph. In each study (1-4), the pitot flowmeter was connected in series with a pneumotachograph under either static flow (flow generator inline or on a face model) or dynamic flow (subject breathing via a polyester face model or on a nasal mask) conditions. The technical characteristics of the pitot flowmeter showed that, (1) the airflow resistance ranged from 0.065 ± 0.002 to 0.279 ± 0.004 cm H(2)O L(-1) s(-1) over the airflow rates of 10 to 50 L min(-1). (2) On the polyester face model there was a linear relationship between airflow as measured by the pitot flowmeter output voltage and the calibrated pneumotachograph signal a (β(1) = 1.08 V L(-1) s(-1); β(0) = 2.45 V). The clinically relevant performance characteristics (hypopnea detection) showed that (3) when the pitot flowmeter was connected via a mask to the human face model, both the sensitivity and specificity for detecting a 50% decrease in peak-to-peak airflow amplitude was 99.2%. When tested in sleeping human subjects, (4) the pitot flowmeter signal displayed 94.5% sensitivity and 91.5% specificity for the detection of 50% peak-to-peak reductions in pneumotachograph-measured airflow. Our data

  8. Statistical data analysis method for multi-zonal airflow measurement using multiple kinds of perfluorocarbon tracer gas

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, Hiroyasu; Onishi, Yoshinori [Institute of Technology, Shimizu Corporation, 4-17, Etchujima 3-chome, Koto-ku, Tokyo 135-8530 (Japan); Tanabe, Shin-ichi [School of Science and Engineering, Department of Architecture, Waseda University, 3-4-1 Okubo, Shinjyuku-ku, Tokyo 169-8555 (Japan); Kashihara, Seiichi [R and D Laboratories, Asahi Kasei Homes Corporation, 2-1, Samejima Fuji-shi, Shizuoka 416-8501 (Japan)

    2009-03-15

    Conventional multi-zonal ventilation measurement methods by multiple types of perfluorocarbon tracers use a number of different gases equal to the number of zones (n). The possible n x n+n airflows are estimated from the mass balance of the gases and the airflow balance. However, some airflows may not occur because of inter-zonal geometry, and the introduction of unnecessary, unknown parameters can impair the accuracy of the estimation. Also, various error factors often yield an irrational negative airflow rate. Conventional methods are insufficient for the evaluation of error. This study describes a way of using the least-squares technique to improve the precision of estimation and to evaluate reliability. From the equations' residual, the error variance-covariance matrix {lambda}{sub q} of the estimated airflow rate error is deduced. In addition, the coefficient of determinant using the residual sum of squares and total variation is introduced. Furthermore, the error matrix{sub m}{lambda}{sub q} from the measurement errors in the gas concentration and gas emission rate is deduced. The discrepancy ratio of the model premises is defined by dividing the diagonal elements of the former by those of the latter. Moreover, the index of irrationality of the estimated negative airflow rate is defined, based on the different results of the three estimation methods. Some numerical experiments are also carried out to verify the flow rate estimation and the reliability evaluation theory. (author)

  9. Temperature-controlled airflow ventilation in operating rooms compared with laminar airflow and turbulent mixed airflow.

    Science.gov (United States)

    Alsved, M; Civilis, A; Ekolind, P; Tammelin, A; Andersson, A Erichsen; Jakobsson, J; Svensson, T; Ramstorp, M; Sadrizadeh, S; Larsson, P-A; Bohgard, M; Šantl-Temkiv, T; Löndahl, J

    2018-02-01

    To evaluate three types of ventilation systems for operating rooms with respect to air cleanliness [in colony-forming units (cfu/m 3 )], energy consumption and comfort of working environment (noise and draught) as reported by surgical team members. Two commonly used ventilation systems, vertical laminar airflow (LAF) and turbulent mixed airflow (TMA), were compared with a newly developed ventilation technique, temperature-controlled airflow (T c AF). The cfu concentrations were measured at three locations in an operating room during 45 orthopaedic procedures: close to the wound (draught. T c AF and LAF remove bacteria more efficiently from the air than TMA, especially close to the wound and at the instrument table. Like LAF, the new T c AF ventilation system maintained very low levels of cfu in the air, but T c AF used substantially less energy and provided a more comfortable working environment than LAF. This enables energy savings with preserved air quality. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Airflow Patterns In Nuclear Workplace - Computer Simulation And Qualitative Tests

    International Nuclear Information System (INIS)

    Haim, M.; Szanto, M.; Weiss, Y.; Kravchick, T.; Levinson, S.; German, U.

    1999-01-01

    Concentration of airborne radioactive materials inside a room can vary widely from one location to another, sometimes by orders of magnitude even for locations that are relatively close. Inappropriately placed samplers can give misleading results and. therefore, the location of air samplers is important. Proper placement of samplers cannot be determined simply by observing the position of room air supply and exhaust vents. Airflow studies, such as the release of smoke aerosols, should be used. The significance of airflow pattern studies depends on the purpose of sampling - for estimating worker intakes, warning of high concentrations. defacing airborne radioactive areas, testing for confinement of sealed radioactive materials. etc. When sampling air in rooms with complex airflow patterns, it may be useful to use qualitative airflow studies with smoke tubes, smoke candles or isostatic bubbles. The U.S. Nuclear Regulatory Commission - Regulatory Guide 8.25 [1]. suggests that an airflow study should be conducted after any changes at work area including changes in the setup of work areas, ventilation system changes, etc. The present work presents an airflow patterns study conducted in a typical room using two methods: a computer simulation and a qualitative test using a smoke tube

  11. Airflow-Restricting Mask Reduces Acute Performance in Resistance Exercise

    Directory of Open Access Journals (Sweden)

    Yuri L. Motoyama

    2016-09-01

    Full Text Available Background: The aim of this study was to compare the number of repetitions to volitional failure, the blood lactate concentration, and the perceived exertion to resistance training with and without an airflow-restricting mask. Methods: Eight participants participated in a randomized, counterbalanced, crossover study. Participants were assigned to an airflow-restricting mask group (MASK or a control group (CONT and completed five sets of chest presses and parallel squats until failure at 75% one-repetition-maximum test (1RM with 60 s of rest between sets. Ratings of perceived exertion (RPEs, blood lactate concentrations (Lac−, and total repetitions were taken after the training session. Results: MASK total repetitions were lower than those of the CONT, and (Lac− and MASK RPEs were higher than those of the CONT in both exercises. Conclusions: We conclude that an airflow-restricting mask in combination with resistance training increase perceptions of exertion and decrease muscular performance and lactate concentrations when compared to resistance training without this accessory. This evidence shows that the airflow-restricting mask may change the central nervous system and stop the exercise beforehand to prevent some biological damage.

  12. Diurnal and seasonal variation in air exchange rates and interzonal airflows measured by active and passive tracer gas in homes

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Gustavsen, Sine; Frederiksen, Marie

    2016-01-01

    Outdoor air delivery to buildings is an important parameter in the assessment of pollutant exposure indoors. Detailed and well controlled measurements of air exchange rates (AER) and interzonal airflows in residential environment are scarce. We measured the outdoor AERs in up to six rooms in five...... rooms. Window opening behavior had a strong influence on AERs, which were highest during occupied daytime periods, lowest in the night; highest in the summer, lowest in the winter. Significant differences were found between AERs measured by the different techniques. The median nighttime AER in all...... studied the pollutant distribution from one room (source room) and interzonal airflows across the dwellings. The air within a given floor was well mixed, with the average tracer gas concentration in the non-source rooms reaching approximately 70% of the source room concentration. There was less air...

  13. Influence of staircase ventilation state on the airflow and heat transfer of the heated room on the middle floor of high rise building

    International Nuclear Information System (INIS)

    Shi, W.X.; Ji, J.; Sun, J.H.; Lo, S.M.; Li, L.J.; Yuan, X.Y.

    2014-01-01

    Highlights: • Experiments are conducted in a scaled building model. • The flow and heat transfer in the heated room are investigated. • The staircase ventilation state influence on the heated room. • The results are useful to understand the safety and energy efficiency of building. - Abstract: Safety and energy efficiency of high rise buildings have attracted public attention in recent decades. In this paper, a set of experiments was conducted in a scaled building model with 12 floors to study the influence of the staircase ventilation state on the flow and heat transfer of the heated room on the middle floor. The airflow, room temperature and fuel burning rate were investigated. It is found that when the window above the heated room is opened, the vents state below the heated room has a significant effect on the airflow and heat transfer in the heated room. When the vents below the heated room are closed, the single-directional air flows into the heated room owing to the stronger stack effect. And the flame tilt angle is larger and the upper hot smoke temperature in the heated room is low. However, when the windows above the heated room are closed, the vents state below the heated room has little influence on the airflow and heat transfer in the heated room. And, there is two-directional air flowing through the door of the heated room The burning rate of heat source is also affected by the staircase ventilation state, and the variation trend varies with the opened window position and pool size

  14. Relationships among smoking habits, airflow limitations, and metabolic abnormalities in school workers.

    Science.gov (United States)

    Horie, Masafumi; Noguchi, Satoshi; Tanaka, Wakae; Goto, Yasushi; Yoshihara, Hisanao; Kawakami, Masaki; Suzuki, Masaru; Sakamoto, Yoshio

    2013-01-01

    Chronic obstructive pulmonary disease is caused mainly by habitual smoking and is common among elderly individuals. It involves not only airflow limitation but also metabolic disorders, leading to increased cardiovascular morbidity and mortality. We evaluated relationships among smoking habits, airflow limitation, and metabolic abnormalities. Between 2001 and 2008, 15,324 school workers (9700 males, 5624 females; age: ≥ 30 years) underwent medical checkups, including blood tests and spirometry. They also responded to a questionnaire on smoking habits and medical history. Airflow limitation was more prevalent in current smokers than in ex-smokers and never-smokers in men and women. The frequency of hypertriglyceridemia was higher in current smokers in all age groups, and those of low high-density-lipoprotein cholesterolemia and diabetes mellitus were higher in current smokers in age groups ≥ 40 s in men, but not in women. There were significant differences in the frequencies of metabolic abnormalities between subjects with airflow limitations and those without in women, but not in men. Smoking index was an independent factor associated with increased frequencies of hypertriglyceridemia (OR 1.015; 95% CI: 1.012-1.018; psmoking cessation was an independent factor associated with a decreased frequency of hypertriglyceridemia (0.984; 0.975-0.994; p = 0.007). Habitual smoking causes high incidences of airflow limitation and metabolic abnormalities. Women, but not men, with airflow limitation had higher frequencies of metabolic abnormalities.

  15. Preparation of ultra-fine calcium carbonate by a solvent-free reaction using supersonic airflow and low temperatures

    OpenAIRE

    Cai, Yan-Hua; Ma, Dong-Mei; Peng, Ru-Fang; Chu, Shi-Jin

    2008-01-01

    The treatment of calcium chloride with sodium carbonate under solvent-free conditions with a supersonic airflow and at a low heating temperature leads to the synthesis of ultra-fine calcium carbonate. The reaction not only involves mild conditions, a simple operation, and high yields but also gives a high conversion rate.

  16. Real-time visualization and analysis of airflow field by use of digital holography

    Science.gov (United States)

    Di, Jianglei; Wu, Bingjing; Chen, Xin; Liu, Junjiang; Wang, Jun; Zhao, Jianlin

    2013-04-01

    The measurement and analysis of airflow field is very important in fluid dynamics. For airflow, smoke particles can be added to visually observe the turbulence phenomena by particle tracking technology, but the effect of smoke particles to follow the high speed airflow will reduce the measurement accuracy. In recent years, with the advantage of non-contact, nondestructive, fast and full-field measurement, digital holography has been widely applied in many fields, such as deformation and vibration analysis, particle characterization, refractive index measurement, and so on. In this paper, we present a method to measure the airflow field by use of digital holography. A small wind tunnel model made of acrylic glass is built to control the velocity and direction of airflow. Different shapes of samples such as aircraft wing and cylinder are placed in the wind tunnel model to produce different forms of flow field. With a Mach-Zehnder interferometer setup, a series of digital holograms carrying the information of airflow filed distributions in different states are recorded by CCD camera and corresponding holographic images are numerically reconstructed from the holograms by computer. Then we can conveniently obtain the velocity or pressure information of the airflow deduced from the quantitative phase information of holographic images and visually display the airflow filed and its evolution in the form of a movie. The theory and experiment results show that digital holography is a robust and feasible approach for real-time visualization and analysis of airflow field.

  17. Interactions of bluff-body obstacles with turbulent airflows affecting evaporative fluxes from porous surfaces

    Science.gov (United States)

    Haghighi, Erfan; Or, Dani

    2015-11-01

    Bluff-body obstacles interacting with turbulent airflows are common in many natural and engineering applications (from desert pavement and shrubs over natural surfaces to cylindrical elements in compact heat exchangers). Even with obstacles of simple geometry, their interactions within turbulent airflows result in a complex and unsteady flow field that affects surface drag partitioning and transport of scalars from adjacent evaporating surfaces. Observations of spatio-temporal thermal patterns on evaporating porous surfaces adjacent to bluff-body obstacles depict well-defined and persistent zonation of evaporation rates that were used to construct a simple mechanistic model for surface-turbulence interactions. Results from evaporative drying of sand surfaces with isolated cylindrical elements (bluff bodies) subjected to constant turbulent airflows were in good agreement with model predictions for localized exchange rates. Experimental and theoretical results show persistent enhancement of evaporative fluxes from bluff-rough surfaces relative to smooth flat surfaces under similar conditions. The enhancement is attributed to formation of vortices that induce a thinner boundary layer over part of the interacting surface footprint. For a practical range of air velocities (0.5-4.0 m/s), low-aspect ratio cylindrical bluff elements placed on evaporating sand surfaces enhanced evaporative mass losses (relative to a flat surface) by up to 300% for high density of elements and high wind velocity, similar to observations reported in the literature. Concepts from drag partitioning were used to generalize the model and upscale predictions to evaporation from surfaces with multiple obstacles for potential applications to natural bluff-rough surfaces.

  18. Unified approach to the study of solid fuel combustion characteristics at high airflow speeds

    Science.gov (United States)

    Vnuchkov, D. A.; Lukashevich, S. V.; Nalivaychenko, D. G.; Zvegintsev, V. I.

    2017-10-01

    The main objective of the research is the development of guidelines for a unified approach to testing the combustion of different solid fuels in gaseous oxidant high-speed flow, so that research outcomes could be presented in a standardized and cohesive form. All the experiments were performed on a special experimental installation designed for quantification of the burning characteristics of different fuels in a wide range of the airflow parameters at the same geometry of the combustion chamber.

  19. Voluntary Cough Airflow Differentiates Safe versus Unsafe Swallowing in Amyotrophic Lateral Sclerosis

    Science.gov (United States)

    Plowman, Emily K.; Watts, Stephanie A.; Robison, Raele; Tabor, Lauren; Dion, Charles; Gaziano, Joy; Vu, Tuan; Gooch, Clifton

    2016-01-01

    Dysphagia and aspiration are prevalent in amyotrophic lateral sclerosis (ALS) and contribute to malnutrition, aspiration pneumonia and death. Early detection of at risk individuals is critical to ensure maintenance of safe oral intake and optimal pulmonary function. We therefore aimed to determine the discriminant ability of voluntary cough airflow measures in detecting penetration/aspiration status in ALS patients. Seventy individuals with ALS (El-Escorial criteria) completed voluntary cough spirometry testing and underwent a standardized videofluoroscopic swallowing evaluation (VFSE). A rater blinded to aspiration status derived six objective measures of voluntary cough airflow and evaluated airway safety using the Penetration Aspiration Scale (PAS). A between groups ANOVA (safe vs. unsafe swallowers) was conducted and sensitivity, specificity, area under the curve (AUC) and likelihood ratios were calculated. VFSE analysis revealed 24 penetrator/aspirators (PAS ≥3) and 46 non-penetrator/aspirators (PAS ≤2). Cough volume acceleration (CVA), peak expiratory flow rise time (PEFRT), and peak expiratory flow rate (PEFR) were significantly different between airway safety groups (p 76ms had sensitivities of 91.3%, 82.6% and 73.9% respectively and specificities of 82.2%, 73.9%, and 78.3% for identifying ALS penetrator/aspirators. Voluntary cough airflow measures identified ALS patients at risk for penetration/aspiration and may be a valuable screening tool with high clinical utility. PMID:26803772

  20. Airflow obstruction in young adults in Canada

    DEFF Research Database (Denmark)

    Al-Hazmi, Manal; Wooldrage, Kate; Anthonisen, Nicholas R.

    2007-01-01

    OBJECTIVE: Airflow obstruction is relatively uncommon in young adults, and may indicate potential for the development of progressive disease. The objective of the present study was to enumerate and characterize airflow obstruction in a random sample of Canadians aged 20 to 44 years. SETTING: The ...

  1. Airflow Pattern Genereated by Three Air Diffusers

    DEFF Research Database (Denmark)

    Olmedo, Inés; Nielsen, Peter V.; de Adana, Manuel Ruiz

    The correct description of air diffusers plays a crucial role in the CFD predictions of the airflow pattern into a room. The numerical simulation of air distribution in an indoor space is challenging because of the complicated airflow pattern generated. An experimental study has been carried out...... in a full scale test room, 4.10 m (length), 3.20 m (width), and 2.70 m (height), in order to take velocity measurements of the airflow pattern generated by three different air diffusers: displacement, mixing and a low impulse diffuser. Smoke visualization has been developed to determine the direction...

  2. Morphological measurements in computed tomography correlate with airflow obstruction in chronic obstructive pulmonary disease: systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Xie, XueQian; Oudkerk, Matthijs; Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands (CMI-NEN), Department of Radiology, Hanzeplein 1, P.O. Box 30.001, RB, Groningen (Netherlands); Jong, Pim A. de [University Medical Center Utrecht, University of Utrecht, Department of Radiology, Heidelberglaan 100, P.O. Box 85.500, CX, Utrecht (Netherlands); Wang, Ying [Tianjin Medical University General Hospital, Department of Radiology, Tianjin (China); Hacken, Nick H.T. ten [University of Groningen, University Medical Center Groningen, Department of Pulmonary Diseases, Hanzeplein 1, P.O. Box 30.001, RB, Groningen (Netherlands); Miao, Jingtao; Zhang, GuiXiang [Shanghai Jiao Tong University Affiliated First People' s Hospital, Department of Radiology, Shanghai (China); Bock, Geertruida H. de [University of Groningen, University Medical Center Groningen, Department of Epidemiology, Hanzeplein 1, P.O. Box 30.001, RB, Groningen (Netherlands)

    2012-10-15

    To determine the correlation between CT measurements of emphysema or peripheral airways and airflow obstruction in chronic obstructive pulmonary disease (COPD). PubMed, Embase and Web of Knowledge were searched from 1976 to 2011. Two reviewers independently screened 1,763 citations to identify articles that correlated CT measurements to airflow obstruction parameters of the pulmonary function test in COPD patients, rated study quality and extracted information. Three CT measurements were accessed: lung attenuation area percentage < -950 Hounsfield units, mean lung density and airway wall area percentage. Two airflow obstruction parameters were accessed: forced expiratory volume in the first second as percentage from predicted (FEV{sub 1} %pred) and FEV{sub 1} divided by the forced volume vital capacity. Seventy-nine articles (9,559 participants) were included in the systematic review, demonstrating different methodologies, measurements and CT airflow obstruction correlations. There were 15 high-quality articles (2,095 participants) in the meta-analysis. The absolute pooled correlation coefficients ranged from 0.48 (95 % CI, 0.40 to 0.54) to 0.65 (0.58 to 0.71) for inspiratory CT and 0.64 (0.53 to 0.72) to 0.73 (0.63 to 0.80) for expiratory CT. CT measurements of emphysema or peripheral airways are significantly related to airflow obstruction in COPD patients. CT provides a morphological method to investigate airway obstruction in COPD. (orig.)

  3. Airflow Pattern Generated by Three Air Diffusers

    DEFF Research Database (Denmark)

    Olmedo, Inés; Nielsen, Peter V.; Ruiz de Adana, Manuel

    2011-01-01

    The correct description of air diffusers plays a crucial role in the CFD predictions of the airflow pattern into a room. The numerical simulation of air distribution in an indoor space is challenging because of the complicated airflow pattern generated. Many authors have developed simplified geom...

  4. Morphological measurements in computed tomography correlate with airflow obstruction in chronic obstructive pulmonary disease: systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Xie, XueQian; Oudkerk, Matthijs; Vliegenthart, Rozemarijn; Jong, Pim A. de; Wang, Ying; Hacken, Nick H.T. ten; Miao, Jingtao; Zhang, GuiXiang; Bock, Geertruida H. de

    2012-01-01

    To determine the correlation between CT measurements of emphysema or peripheral airways and airflow obstruction in chronic obstructive pulmonary disease (COPD). PubMed, Embase and Web of Knowledge were searched from 1976 to 2011. Two reviewers independently screened 1,763 citations to identify articles that correlated CT measurements to airflow obstruction parameters of the pulmonary function test in COPD patients, rated study quality and extracted information. Three CT measurements were accessed: lung attenuation area percentage 1 %pred) and FEV 1 divided by the forced volume vital capacity. Seventy-nine articles (9,559 participants) were included in the systematic review, demonstrating different methodologies, measurements and CT airflow obstruction correlations. There were 15 high-quality articles (2,095 participants) in the meta-analysis. The absolute pooled correlation coefficients ranged from 0.48 (95 % CI, 0.40 to 0.54) to 0.65 (0.58 to 0.71) for inspiratory CT and 0.64 (0.53 to 0.72) to 0.73 (0.63 to 0.80) for expiratory CT. CT measurements of emphysema or peripheral airways are significantly related to airflow obstruction in COPD patients. CT provides a morphological method to investigate airway obstruction in COPD. (orig.)

  5. COMPUTATIONAL MODELING OF AIRFLOW IN NONREGULAR SHAPED CHANNELS

    Directory of Open Access Journals (Sweden)

    A. A. Voronin

    2013-05-01

    Full Text Available The basic approaches to computational modeling of airflow in the human nasal cavity are analyzed. Different models of turbulent flow which may be used in order to calculate air velocity and pressure are discussed. Experimental measurement results of airflow temperature are illustrated. Geometrical model of human nasal cavity reconstructed from computer-aided tomography scans and numerical simulation results of airflow inside this model are also given. Spatial distributions of velocity and temperature for inhaled and exhaled air are shown.

  6. Contamination control in HVAC systems for aseptic processing area. Part I: Case study of the airflow velocity in a unidirectional airflow workstation with computational fluid dynamics.

    Science.gov (United States)

    Ogawa, M

    2000-01-01

    A unidirectional airflow workstation for processing a sterile pharmaceutical product is required to be "Grade A," according to EU-GMP and WHO-GMP. These regulations have employed the wording of "laminar airflow" for unidirectional airflow, with an unclear definition given. This seems to have allowed many reports to describe discussion of airflow velocity only. The guidance values as to the velocity are expressed in various words of 90 ft/min, 0.45 m/sec, 0.3 m/sec, +/- 20%, or "homogeneous air speed." It has been also little clarified how variation in airflow velocity gives influences on contamination control of a workstation working with varying key characteristics, such as ceiling height, internal heat load, internal particle generation, etc. The present author has revealed following points from a case study using Computational Fluid Dynamics: the airflow characteristic in Grade A area shows no significant changes with varying the velocity of supplied airflow, and the particles generated from the operator will be exhausted outside Grade A area without contamination.

  7. Measured Performance of a Varied Airflow Small-Diameter Duct System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-03-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  8. Measured Performance of a Varied Airflow Small-Diameter Duct System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-03-16

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  9. Real-time monitoring for alpha emitters in high-airflow environments

    International Nuclear Information System (INIS)

    Koster, J.E.; MacArthur, D.W.; Bounds, J.A.; Rawool-Sullivan, M.; Whitley, C.R.; Conaway, J.G.; Steadman, P.A.

    1996-01-01

    Key problems in detecting alpha contamination for site characterization and decontamination and decommissioning that remain to be solved include measurement of airborne contamination, material holdup within pipes, and leakage of material containers. These problems are very difficult using traditional alpha detectors and systems. The ionization detection method (long-range alpha detection of LRAD) offers a number of specific advantages for these environmental measurements. An LRAD system detects the air molecules ionized by alpha-emitting contamination rather than the alpha particles. Thus, LRAD-based detectors are not limited by the short range of alpha particles and can be used to detect contamination anywhere that air can penetrate. Extending this technology to large enclosures of long pipes requires a system optimized for large airflows. In this paper we will present designs and preliminary results for high-volume flow-through air monitors based on the LRAD technique. In addition, we will discuss the behavior of the monitors and their potential applications

  10. Fault tolerant attitude control for small unmanned aircraft systems equipped with an airflow sensor array.

    Science.gov (United States)

    Shen, H; Xu, Y; Dickinson, B T

    2014-11-18

    Inspired by sensing strategies observed in birds and bats, a new attitude control concept of directly using real-time pressure and shear stresses has recently been studied. It was shown that with an array of onboard airflow sensors, small unmanned aircraft systems can promptly respond to airflow changes and improve flight performances. In this paper, a mapping function is proposed to compute aerodynamic moments from the real-time pressure and shear data in a practical and computationally tractable formulation. Since many microscale airflow sensors are embedded on the small unmanned aircraft system surface, it is highly possible that certain sensors may fail. Here, an adaptive control system is developed that is robust to sensor failure as well as other numerical mismatches in calculating real-time aerodynamic moments. The advantages of the proposed method are shown in the following simulation cases: (i) feedback pressure and wall shear data from a distributed array of 45 airflow sensors; (ii) 50% failure of the symmetrically distributed airflow sensor array; and (iii) failure of all the airflow sensors on one wing. It is shown that even if 50% of the airflow sensors have failures, the aircraft is still stable and able to track the attitude commands.

  11. Majority of never-smokers with airflow limitation do not have asthma

    DEFF Research Database (Denmark)

    Çolak, Yunus; Afzal, Shoaib; Nordestgaard, Børge G

    2016-01-01

    BACKGROUND: A substantial proportion of individuals with airflow limitation are never-smokers. However, whether never-smokers with airflow limitation have undiagnosed asthma is unknown. We hypothesised that the majority of never-smokers with respiratory symptoms and airflow limitation but without...... known asthma have undiagnosed asthma by comparing characteristics and prognosis in never-smokers with airflow limitation and asthma (NS+AFL+A) with never-smokers with airflow limitation but without asthma (NS+AFL-A). METHODS: Among 94 079 participants aged 20-100 years from the general population, 39...... 102 (42%) were never-smokers. In this group, 13 719 (35%) reported to have respiratory symptoms of whom 1610 (12%) had airflow limitation. We investigated characteristics and risk of complications (asthma or COPD exacerbations, pneumonias and all-cause mortality) and comorbidities (lung cancer...

  12. Airflow in Tracheobronchial Tree of Subjects with Tracheal Bronchus Simulated Using CT Image Based Models and CFD Method.

    Science.gov (United States)

    Qi, Shouliang; Zhang, Baihua; Yue, Yong; Shen, Jing; Teng, Yueyang; Qian, Wei; Wu, Jianlin

    2018-03-01

    Tracheal Bronchus (TB) is a rare congenital anomaly characterized by the presence of an abnormal bronchus originating from the trachea or main bronchi and directed toward the upper lobe. The airflow pattern in tracheobronchial trees of TB subjects is critical, but has not been systemically studied. This study proposes to simulate the airflow using CT image based models and the computational fluid dynamics (CFD) method. Six TB subjects and three health controls (HC) are included. After the geometric model of tracheobronchial tree is extracted from CT images, the spatial distribution of velocity, wall pressure, wall shear stress (WSS) is obtained through CFD simulation, and the lobar distribution of air, flow pattern and global pressure drop are investigated. Compared with HC subjects, the main bronchus angle of TB subjects and the variation of volume are large, while the cross-sectional growth rate is small. High airflow velocity, wall pressure, and WSS are observed locally at the tracheal bronchus, but the global patterns of these measures are still similar to those of HC. The ratio of airflow into the tracheal bronchus accounts for 6.6-15.6% of the inhaled airflow, decreasing the ratio to the right upper lobe from 15.7-21.4% (HC) to 4.9-13.6%. The air into tracheal bronchus originates from the right dorsal near-wall region of the trachea. Tracheal bronchus does not change the global pressure drop which is dependent on multiple variables. Though the tracheobronchial trees of TB subjects present individualized features, several commonalities on the structural and airflow characteristics can be revealed. The observed local alternations might provide new insight into the reason of recurrent local infections, cough and acute respiratory distress related to TB.

  13. Low-airflow drying of fungicide-treated shelled corn

    International Nuclear Information System (INIS)

    Peterson, W.H.; Benson, P.W.

    1993-02-01

    Approved fungicides inhibit mold growth in shelled corn and allow for longer, natural-air drying. The longer drying periods permit lower than-normal airflows and smaller power units, thus reducing electrical demands on utilities in corn-producing states. Researchers placed approximately 67 m 3 (1900 bu) of one variety of shelled corn at approximately 24% moisture in each of five equally sized storage bins. They partitioned each bin vertically and filled one half of each bin with fungicide-treated corn and one half with untreated corn. Each of four bins used a different airflow. A fifth bin used the lowest of the four airflows but was equipped to capture and use solar energy. All corn dried rapidly with resulting good quality. The percentage of damaged kernels was significantly higher for untreated than for treated corn. The energy required for the lowest airflow system was approximately one half of that required for the higher, more traditional airflows. Because of lower-than-normal airflows, the electrical demand on the utility is approximately one fourth as great as that imposed when the higher, more traditional natural-air systems are used. The 1991 corn growing and drying seasons were unusual in central Illinois, the site of the study. Both harvest and drying occurred several weeks ahead of schedule. Additional work is needed to verify that findings hold true during more-normal Midwest corn growing and drying seasons; the investigators predict that they will. It should be noted that the fungicide used in this study has not yet been approved for widespread use in drying corn

  14. Integration of a Multizone Airflow Model into a Thermal simulation Program

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Sørensen, Karl Grau; Heiselberg, Per

    2007-01-01

    An existing computer model for dynamic hygrothermal analysis of buildings has been extended with a multizone airflow model based on loop equations to account for the coupled thermal and airflow in natural and hybrid ventilated buildings.......An existing computer model for dynamic hygrothermal analysis of buildings has been extended with a multizone airflow model based on loop equations to account for the coupled thermal and airflow in natural and hybrid ventilated buildings....

  15. Scoliosis associated with airflow obstruction due to endothoracic vertebral hump.

    Science.gov (United States)

    Ito, Kenyu; Kawakami, Noriaki; Miyasaka, Kazuyoshi; Tsuji, Taichi; Ohara, Tetsuya; Nohara, Ayato

    2012-12-01

    A retrospective clinical study of scoliosis-associated airflow obstruction due to endothoracic vertebral hump. The purpose of this study was to evaluate and present anatomical features of patients with scoliosis who showed airflow obstruction caused by endothoracic vertebral hump. It is well known that severe scoliosis causes airflow restriction due to thoracic cage deformity. There have been few reports of clinical data and anatomical features on scoliosis associated with airflow obstruction due to endothoracic vertebral hump. The subjects were 6 patients. The diagnoses were idiopathic scoliosis in 3 patients, symptomatic scoliosis in 2 patients, and thoracogenic scoliosis in 1 patient. The radiological outcome, comorbidities, pre- and postoperative respiratory function, and surgical complication were analyzed. Four patients had preoperative atelectasis on the convex side of the lower lobe and improved after the operations. All patients showed main thoracic curves and their apex was located at T7-T9. All patients had lordoscoliosis except 1, who demonstrated kyphosing scoliosis. The correction rate was 78% (62.8%-83.5%). Preoperative thoracic lordosis within the range of -5° to -47° was postoperatively corrected to a substantially normal kyphosis within the range of 9° to 24°. The average vital capacity, percent VC improved from 0.72 L (0.33-1.17 L) to 1.21 L (0.82-1.71 L) and 45.5% (37.3%- 50.8%) to 63.7% (41.0%-88.6%) relatively. Spine Penetration Index improved from 23% (18%-35%) to 16% (13%-19%). Endothoracic hump ratio improved from 1.34 (0.98-1.93) to 1.12 (0.86-1.28). Each patient with symptomatic scoliosis and thoracogenic scoliosis required relatively long periods of respiration management. Patients having lordoscoliosis with an apex located between T7 and T9 may develop airflow obstruction due to an endothoracic vertebral hump. Correction of lordoscoliosis through anterior and posterior approaches successfully improved endothoracic hump ratio and

  16. Airflow patterns in complex workplaces

    International Nuclear Information System (INIS)

    Mishima, J.; Selby, J.M.; Lynch, T.P.; Langer, G.; Vallario, E.J.

    1987-01-01

    There are many considerations in obtaining an accurate evaluation of aerosols. One aspect that has been neglected is the study of airflow patterns within the workplace. In many nuclear facilities, the operations performed required extensive equipment (e.g., glove boxes, piping) that create complex arrangements of physical barriers to flow. To provide samples of the airborne materials, particularly particles, knowledge of these complex airflow patterns is required for sampler placement. Recent studies have shown that materials introduced into the air flow within a workplace act as plumes embedded in major airflow streams. Portions of the plumes can recycle through the ventilated area, be lost to dead air pockets, or exhaust through unusual, unexpected outlets. Unusual flow patterns are observed even in relatively uncomplicated arrangements of equipment. This behavior must be factored into sampling/monitoring programs for evaluation of the airborne hazard to personnel within the workplace consistent with the objective of the program. Other factors that also must be considered to provide valid samples of airborne particulate materials are objectives of the sampling program, characteristics of the airborne particulate materials, nonsegregatory transport for the extracted materials, and requirements for the measurement techniques used

  17. Prevalence of airflow limitation in outpatients with cardiovascular diseases in Japan

    Directory of Open Access Journals (Sweden)

    Onishi K

    2014-05-01

    Full Text Available Katsuya Onishi,1 Daisuke Yoshimoto,2 Gerry W Hagan,3 Paul W Jones4 1Onishi Heart Clinic, Mie, 2Medical Affairs Respiratory, GlaxoSmithKline KK, Tokyo, Japan; 3Independent Consultant, Marbella, Spain; 4Division of Clinical Science, St George's, University of London, London, UK Background and objectives: Cardiovascular disease (CVD and chronic obstructive pulmonary disease (COPD commonly coexist and share common risk factors. The prevalence of COPD in outpatients with a smoking history and CVD in Japan is unknown. The aim of this study was to determine the proportion of Japanese patients with a smoking history being treated for CVD who have concurrent airflow limitation compatible with COPD. A secondary objective was to test whether the usage of lung function tests performed in the clinic influenced the diagnosis rate of COPD in the patients identified with airflow limitation. Methods: In a multicenter observational prospective study conducted at 17 centers across Japan, the prevalence of airflow limitation compatible with COPD (defined as forced expiratory volume (FEV1/FEV6 <0.73, by handheld spirometry was investigated in cardiac outpatients ≥40 years old with a smoking history who routinely visited the clinic for their CVD. Each patient completed the COPD Assessment Test prior to spirometry testing. Results: Data were available for 995 patients with a mean age of 66.6±10.0 years, of whom 95.5% were male. The prevalence of airflow limitation compatible with COPD was 27.0% (n=269, and 87.7% of those patients (n=236 did not have a prior diagnosis of COPD. The prevalence of previously diagnosed airflow limitation was higher in sites with higher usage of lung function testing (14.0%, 15.2% respectively compared against sites where it is performed seldom (11.1%, but was still low. Conclusion: The prevalence of airflow limitation in this study indicates that a quarter of outpatients with CVD have COPD, almost all of whom are undiagnosed. This

  18. Experimental investigation into the interaction between the human body and room airflow and its effect on thermal comfort under stratum ventilation.

    Science.gov (United States)

    Cheng, Y; Lin, Z

    2016-04-01

    Room occupants' comfort and health are affected by the airflow. Nevertheless, they themselves also play an important role in indoor air distribution. This study investigated the interaction between the human body and room airflow under stratum ventilation. Simplified thermal manikin was employed to effectively resemble the human body as a flow obstacle and/or free convective heat source. Unheated and heated manikins were designed to fully evaluate the impact of the manikin at various airflow rates. Additionally, subjective human tests were conducted to evaluate thermal comfort for the occupants in two rows. The findings show that the manikin formed a local blockage effect, but the supply airflow could flow over it. With the body heat from the manikin, the air jet penetrated farther compared with that for the unheated manikin. The temperature downstream of the manikin was also higher because of the convective effect. Elevating the supply airflow rate from 7 to 15 air changes per hour varied the downstream airflow pattern dramatically, from an uprising flow induced by body heat to a jet-dominated flow. Subjective assessments indicated that stratum ventilation provided thermal comfort for the occupants in both rows. Therefore, stratum ventilation could be applied in rooms with occupants in multiple rows. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Current status of nuclear medicine in chronic airflow limitation

    International Nuclear Information System (INIS)

    Clarke, S.W.; Agnew, J.E.; Royal Free Hospital, London

    1987-01-01

    Radionuclide imaging, quite apart from its role in the diagnosis of pulmonary embolism, offers information about the distribution of ventilatory and perfusion abnormalities within the lung. The extent of ventilatory abnormality seen can be related to the severity of airways obstruction as assessed spirometrically, whilst abnormalities in the matching of perfusion to ventilation can be related to the severity of hypoxaemia in patients with chronic airflow limitation. Clearance of mucus from the lungs of patients with chronic mucus hypersection may be assessed by following the clearance rate of insoluble radioaerosol particles; by such means the relative contributions of mucociliary transport and of cough to the overall clearance can be observed. Clearance is often severely impaired in patients with airways obstruction; the radioaerosol technique can be used to determine the effects of drug or physiotherapy treatment. Chronic airflow limitation leading to hypoxaemia can be associated with pulmonary artery hypertension and right ventricular hypertrophy - this may be investigated noninvasively by a radionuclide test of right ventricular ejection fraction. (orig.)

  20. Current status of nuclear medicine in chronic airflow limitation

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, S.W.; Agnew, J.E.

    1987-06-01

    Radionuclide imaging, quite apart from its role in the diagnosis of pulmonary embolism, offers information about the distribution of ventilatory and perfusion abnormalities within the lung. The extent of ventilatory abnormality seen can be related to the severity of airways obstruction as assessed spirometrically, whilst abnormalities in the matching of perfusion to ventilation can be related to the severity of hypoxaemia in patients with chronic airflow limitation. Clearance of mucus from the lungs of patients with chronic mucus hypersection may be assessed by following the clearance rate of insoluble radioaerosol particles; by such means the relative contributions of mucociliary transport and of cough to the overall clearance can be observed. Clearance is often severely impaired in patients with airways obstruction; the radioaerosol technique can be used to determine the effects of drug or physiotherapy treatment. Chronic airflow limitation leading to hypoxaemia can be associated with pulmonary artery hypertension and right ventricular hypertrophy - this may be investigated noninvasively by a radionuclide test of right ventricular ejection fraction.

  1. Airflow Obstruction and Use of Solid Fuels for Cooking or Heating: BOLD Results.

    Science.gov (United States)

    Amaral, André F S; Patel, Jaymini; Kato, Bernet S; Obaseki, Daniel O; Lawin, Hervé; Tan, Wan C; Juvekar, Sanjay K; Harrabi, Imed; Studnicka, Michael; Wouters, Emiel F M; Loh, Li-Cher; Bateman, Eric D; Mortimer, Kevin; Buist, A Sonia; Burney, Peter G J

    2017-09-12

    Evidence supporting the association of COPD or airflow obstruction with use of solid fuels is conflicting and inconsistent. To assess the association of airflow obstruction with self-reported use of solid fuels for cooking or heating. We analysed 18,554 adults from the BOLD study, who had provided acceptable post-bronchodilator spirometry measurements and information on use of solid fuels. The association of airflow obstruction with use of solid fuels for cooking or heating was assessed by sex, within each site, using regression analysis. Estimates were stratified by national income and meta-analysed. We carried out similar analyses for spirometric restriction, chronic cough and chronic phlegm. We found no association between airflow obstruction and use of solid fuels for cooking or heating (ORmen=1.20, 95%CI 0.94-1.53; ORwomen=0.88, 95%CI 0.67-1.15). This was true for low/middle and high income sites. Among never smokers there was also no evidence of an association of airflow obstruction with use of solid fuels (ORmen=1.00, 95%CI 0.57-1.76; ORwomen=1.00, 95%CI 0.76-1.32). Overall, we found no association of spirometric restriction, chronic cough or chronic phlegm with the use of solid fuels. However, we found that chronic phlegm was more likely to be reported among female never smokers and those who had been exposed for ≥20 years. Airflow obstruction assessed from post-bronchodilator spirometry was not associated with use of solid fuels for cooking or heating.

  2. Factors associated with persistent airflow limitation in severe asthma

    NARCIS (Netherlands)

    ten Brinke, A.; Zwinderman, A. H.; Sterk, P. J.; Rabe, K. F.; Bel, E. H.

    2001-01-01

    Persistent airflow limitation can develop in nonsmoking patients with asthma. However, the prevalence and risk factors for airways obstruction with incomplete reversibility in asthma are unknown. We assessed the prevalence of persistent airflow limitation (defined as postbronchodilator FEV(1) or

  3. EFFECTS OF TEMPERATURE AND AIRFLOW ON VOLUME DEVELOPMENT DURING BAKING AND ITS INFLUENCE ON QUALITY OF CAKE

    Directory of Open Access Journals (Sweden)

    NURUL ATIQAH SANI

    2014-06-01

    Full Text Available Volume and texture of cake are among the important parameters in measuring the quality of cake. The processing conditions play important roles in producing cakes of good quality. Recent studies focused more on the formulation and the manipulation of baking temperature, humidity and time instead of airflow condition. The objective of this study was to evaluate the effects of baking temperature and airflow on the volume development of cake and final cake quality such as volume development, firmness, springiness and moisture content. The cake was baked at three different temperatures (160oC, 170oC, and 180oC, and two different airflow conditions. Baking time, height changes of batter, texture and moisture content of cake were compared to identify the differences or similarities on the final product as the process conditions varied. Results showed that, airflow has more significant effects towards the product quality compared to baking temperature especially on baking time which was 25.58 - 45.16%, and the rate of height changes which was 0.7 mm/min. However, different baking temperatures had more significant effects towards volume expansion which was 2.86 – 8.37% and the springiness of cake which was 3.44% compared to airflow conditions.

  4. Effects of hot airflow during spin-coating process on CH3NH3PbI3-xClx perovskite solar cells

    Science.gov (United States)

    Tanaka, Hiroki; Ohishi, Yuya; Oku, Takeo

    2018-01-01

    CH3NH3PbI3-xClx photovoltaic devices were fabricated, and the effects of hot airflow during spin-coating were investigated. Cubic perovskite crystals that is a high temperature phase were obtained by the hot airflow method. The conversion efficiencies of the devices prepared by the hot airflow were remained even after 56 days.

  5. Advanced airflow distribution methods for reduction of personal exposure to indoor pollutants

    DEFF Research Database (Denmark)

    Cao, Guangyu; Kosonen, Risto; Melikov, Arsen

    2016-01-01

    The main objective of this study is to recognize possible airflow distribution methods to protect the occupants from exposure to various indoor pollutants. The fact of the increasing exposure of occupants to various indoor pollutants shows that there is an urgent need to develop advanced airflow ...... distribution methods to reduce indoor exposure to various indoor pollutants. This article presents some of the latest development of advanced airflow distribution methods to reduce indoor exposure in various types of buildings.......The main objective of this study is to recognize possible airflow distribution methods to protect the occupants from exposure to various indoor pollutants. The fact of the increasing exposure of occupants to various indoor pollutants shows that there is an urgent need to develop advanced airflow...

  6. Integration of a Multizone Airflow Model into a Thermalsimulation Program

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Sørensen, Karl Grau; Heiselberg, Per

    2007-01-01

    An existing computer model for dynamic hygrothermal analysis of buildings has been extended with a multizone airflow model based on loop equations to account for the coupled thermal and airflow in natural and hybrid ventilated buildings. In water distribution network and related fields loop...... a methodology adopted from water distribution network that automatically sets up the independent loops and is easy to implement into a computer program. Finally an example of verification of the model is given which demonstrates the ability of the models to accurately predict the airflow of a simple multizone...

  7. Unidirectional pulmonary airflow patterns in the savannah monitor lizard.

    Science.gov (United States)

    Schachner, Emma R; Cieri, Robert L; Butler, James P; Farmer, C G

    2014-02-20

    The unidirectional airflow patterns in the lungs of birds have long been considered a unique and specialized trait associated with the oxygen demands of flying, their endothermic metabolism and unusual pulmonary architecture. However, the discovery of similar flow patterns in the lungs of crocodilians indicates that this character is probably ancestral for all archosaurs--the group that includes extant birds and crocodilians as well as their extinct relatives, such as pterosaurs and dinosaurs. Unidirectional flow in birds results from aerodynamic valves, rather than from sphincters or other physical mechanisms, and similar aerodynamic valves seem to be present in crocodilians. The anatomical and developmental similarities in the primary and secondary bronchi of birds and crocodilians suggest that these structures and airflow patterns may be homologous. The origin of this pattern is at least as old as the split between crocodilians and birds, which occurred in the Triassic period. Alternatively, this pattern of flow may be even older; this hypothesis can be tested by investigating patterns of airflow in members of the outgroup to birds and crocodilians, the Lepidosauromorpha (tuatara, lizards and snakes). Here we demonstrate region-specific unidirectional airflow in the lungs of the savannah monitor lizard (Varanus exanthematicus). The presence of unidirectional flow in the lungs of V. exanthematicus thus gives rise to two possible evolutionary scenarios: either unidirectional airflow evolved independently in archosaurs and monitor lizards, or these flow patterns are homologous in archosaurs and V. exanthematicus, having evolved only once in ancestral diapsids (the clade encompassing snakes, lizards, crocodilians and birds). If unidirectional airflow is plesiomorphic for Diapsida, this respiratory character can be reconstructed for extinct diapsids, and evolved in a small ectothermic tetrapod during the Palaeozoic era at least a hundred million years before the

  8. Numerical investigation on thermal performance and correlations of double skin facade with buoyancy-driven airflow

    Energy Technology Data Exchange (ETDEWEB)

    Pappas, Alexandra; Zhai, Zhiqiang [Department of Civil, Environmental and Architectural Engineering, University of Colorado, UCB 428, ECOT 441, Boulder, CO 80309-0428 (United States)

    2008-07-01

    This paper briefly reviews the primary parameters for a double skin facade (DSF) design. The research presents an integrated and iterative modeling process for analyzing the thermal performance of DSF cavities with buoyancy-driven airflow by using a building energy simulation program (BESP) along with a computational fluid dynamics (CFD) package. A typical DSF cavity model has been established and simulated. The model and the modeling process have been calibrated and validated against the experimental data. The validated model was used to develop correlations that can be implemented in a BESP, allowing users to take advantage of the accuracy gained from CFD simulations without the required computation time. Correlations were developed for airflow rate through cavity, average and peak cavity air temperature, cavity air pressure, and interior convection coefficient. The correlations are valuable for 'back of the envelope' calculation and for examining accuracy of zonal-model-based energy and airflow simulation programs. (author)

  9. Simulation of Thermal Distribution and Airflow for Efficient Energy Consumption in a Small Data Centers

    Directory of Open Access Journals (Sweden)

    Jing Ni

    2017-04-01

    Full Text Available Data centers have become ubiquitous in the last few years in an attempt to keep pace with the processing and storage needs of the Internet and cloud computing. The steady growth in the heat densities of IT servers leads to a rise in the energy needed to cool them, and constitutes approximately 40% of the power consumed by data centers. However, many data centers feature redundant air conditioning systems that contribute to inefficient air distribution, which significantly increases energy consumption. This remains an insufficiently explored problem. In this paper, a typical, small data center with tiles for an air supply system with a raised floor is used. We use a fluent (Computational Fluid Dynamics, CFD to simulate thermal distribution and airflow, and investigate the optimal conditions of air distribution to save energy. The effects of the airflow outlet angle along the tile, the cooling temperature and the rate of airflow on the beta index as well as the energy utilization index are discussed, and the optimal conditions are obtained. The reasonable airflow distribution achieved using 3D CFD calculations and the parameter settings provided in this paper can help reduce the energy consumption of data centers by improving the efficiency of the air conditioning.

  10. Airflow Measurement of the Car HVAC Unit Using Hot-wire Anemometry

    Directory of Open Access Journals (Sweden)

    Fojtlín Miloš

    2016-01-01

    Full Text Available Thermal environment in a vehicular cabin significantly influence drivers’ fatigue and passengers’ thermal comfort. This environment is traditionally managed by HVAC cabin system that distributes air and modifies its properties. In order to simulate cabin thermal behaviour, amount of the air led through car vents must be determined. The aim of this study was to develop methodology to measure airflow from the vents, and consequently calculate corresponding air distribution coefficients. Three climatic cases were selected to match European winter, summer, and spring / fall conditions. Experiments were conducted on a test vehicle in a climatic chamber. The car HVAC system was set to automatic control mode, and the measurements were executed after the system stabilisation—each case was independently measured three times. To be able to evaluate precision of the method, the airflow was determined at the system inlet (HVAC suction and outlet (each vent, and the total airflow values were compared. The airflow was calculated by determining a mean value of the air velocity multiplied by an area of inlet / outlet cross-section. Hot-wire anemometry was involved to measure the air velocity. Regarding the summer case, total airflow entering the cabin was around 57 l s-1 with 60 % of the air entering the cabin through dashboard vents; no air was supplied to the feet compartment. The remaining cases had the same total airflow of around 42 l s-1, and the air distribution was focused mainly on feet and windows. The inlet and outlet airflow values show a good match with a maximum mass differential of 8.3 %.

  11. Study on remote control technology of airflow during a mine fire

    Energy Technology Data Exchange (ETDEWEB)

    Wang, D.; Wang, Y; Zhou, Y.; Zhou, F. [China University of Mining and Technology, Jiangsu (China). College of Mineral and Energy Resource

    2001-07-01

    In order to realize remote control of airflow during a mine fire and minimize fire losses, two kinds of the airflow remote control systems have been developed. One uses compressed air as power source, and transmits control signals by a monitor system for mine environment. Another uses electric power and transmits control signals through a telephone network underground. The mine door controllers of the remote airflow controlling systems are developed with a single-chip microcomputer. Then the controller can not only do logical analysis and judgement, but also has a strong anti-disturb ability and sufficient reliability. The two kinds of airflow remote control system have been successfully applied in some coal mines in China. Their effects of running are very good. 2 refs., 5 figs.

  12. Estimation of Airflow in Livestock Buildings using Image Analysis

    DEFF Research Database (Denmark)

    Larsen, Rasmus

    1996-01-01

    of a livestock building, the airflow in a laser-illuminated plane may be visualized. Based on sequences of images recorded of this plane using a video camera, estimates of 2--D flow vectors are derived locally. The local estimates of velocity are found using a set of spatio-temporal convolution filters...... and camera may be placed so they do not disturb the airflow) for estimating air velocity in a 2--D plane.......In order to evaluate a given ventilation system in a livestock building and its sensitivity to wind, presence of heat sources (e.g. livestock) etc. it is of interest to estimate flow vector fields corresponding to the airflow. By introducing particles (e.g. smoke) into the air inlets of a model...

  13. Investigation of airflow effects on the dielectric barrier discharge with single/double discharge channel arrangement

    Science.gov (United States)

    Fan, Zhihui; Yan, Huijie; Liu, Yidi; Guo, Hongfei; Wang, Yuying; Ren, Chunsheng

    2018-05-01

    Atmospheric-pressure dielectric barrier discharge (DBD) with airflow participation has been widely used in recent years. In this paper, effects of airflow on DBD characteristics are experimentally investigated by single/double pin-to-plate DBD arrangements with an AC exciting source. The discharge electrical characteristics and the movements of discharge channels in airflow are investigated with a single pin electrode arrangement. The current intensities increase in positive cycles and decrease in negative cycles with the increase in airflow velocity. The transition from a filamentary discharge to a diffuse discharge is observed under certain airflow conditions, and the discharge channels move with the airflow with a movement velocity less than the corresponding airflow velocity. In the cases of double pin electrode arrangements, the repulsion between double pin discharge channels is apparent at a 10 mm distance but is not obvious at a 20 mm distance. When the airflow is introduced into the discharge gap, not as in the case of single pin electrode arrangement, the movements of discharge channels in airflow are affected by adjacent discharge channels. The corresponding reasons are analyzed in the paper.

  14. Finite Element Modeling of Airflow During Phonation

    Directory of Open Access Journals (Sweden)

    Šidlof P.

    2010-07-01

    Full Text Available In the paper a mathematical model of airflow in human vocal folds is presented. The geometry of the glottal channel is based on measurements of excised human larynges. The airflow is modeled by nonstationary incompressible Navier-Stokes equations in a 2D computational domain, which is deformed in time due to vocal fold vibration. The paper presents numerical results and focuses on flow separation in glottis. Quantitative data from numerical simulations are compared to results of measurements by Particle Image Velocimetry (PIV, performed on a scaled self-oscillating physical model of vocal folds.

  15. Computed tomography structural lung changes in discordant airflow limitation.

    Directory of Open Access Journals (Sweden)

    Firdaus A A Mohamed Hoesein

    Full Text Available There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT quantified emphysema, airway wall thickening and gas trapping according to classification of airflow limitation (FEV1/FVC 70%; group 2LLN; and group 370% but FEV1 <80% predicted, were excluded. Multivariate regression analysis correcting for covariates was used to asses the extent of emphysema, airway wall thickening and gas trapping according to three groups of airflow limitation.Mean (standard deviation age was 62.5 (5.2 years and packyears smoked was 41.0 (18.0. Group 2 subjects when compared to group 1 had a significantly lower 15(th percentile, -920.6 HU versus -912.2 HU; a higher Pi10, 2.87 mm versus 2.57 mm; and a higher E/I-ratio, 88.6% versus 85.6% (all p<0.001.Subjects with an FEV1/FVC<70%, but above the LLN, have a significant greater degree of structural lung changes on CT compared to subjects without airflow limitation.

  16. Impact of acoustic airflow on intrasinus drug deposition: New insights into the vibrating mode and the optimal acoustic frequency to enhance the delivery of nebulized antibiotic.

    Science.gov (United States)

    Leclerc, Lara; Merhie, Amira El; Navarro, Laurent; Prévôt, Nathalie; Durand, Marc; Pourchez, Jérémie

    2015-10-15

    We investigated the impact of vibrating acoustic airflow, the high frequency (f≥100 Hz) and the low frequency (f≤45 Hz) sound waves, on the enhancement of intrasinus drug deposition. (81m)Kr-gas ventilation study was performed in a plastinated human cast with and without the addition of vibrating acoustic airflow. Similarly, intrasinus drug deposition in a nasal replica using gentamicin as a marker was studied with and without the superposition of different modes of acoustic airflow. Ventilation experiments demonstrate that no sinus ventilation was observed without acoustic airflow although sinus ventilation occurred whatever the modes of acoustic airflow applied. Intrasinus drug deposition experiments showed that the high frequency acoustic airflow led to 4-fold increase in gentamicin deposition into the left maxillary sinus and to 2-fold deposition increase into the right maxillary sinus. Besides, the low frequency acoustic airflow demonstrated a significant increase of 4-fold and 2-fold in the right and left maxillary sinuses, respectively. We demonstrated the benefit of different modes of vibrating acoustic airflow for maxillary sinus ventilation and intrasinus drug deposition. The degree of gentamicin deposition varies as a function of frequency of the vibrating acoustic airflow and the geometry of the ostia. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Comparison between mixed and laminar airflow systems in operating rooms and the influence of human factors: experiences from a Swedish orthopedic center.

    Science.gov (United States)

    Erichsen Andersson, Annette; Petzold, Max; Bergh, Ingrid; Karlsson, Jón; Eriksson, Bengt I; Nilsson, Kerstin

    2014-06-01

    The importance of laminar airflow systems in operating rooms as protection from surgical site infections has been questioned. The aim of our study was to explore the differences in air contamination rates between displacement ventilation and laminar airflow systems during planned and acute orthopedic implant surgery. A second aim was to compare the influence of the number of people present, the reasons for traffic flow, and the door-opening rates between the 2 systems. Active air sampling and observations were made during 63 orthopedic implant operations. The laminar airflow system resulted in a reduction of 89% in colony forming units in comparison with the displacement system (P operating rooms offer high-quality air during surgery, with very low levels of colony forming units close to the surgical wound. The continuous maintenance of laminar air flow and other technical systems are crucial, because minor failures in complex systems like those in operating rooms can result in a detrimental effect on air quality and jeopardize the safety of patients. The technical ventilation solutions are important, but they do not guarantee clean air, because many other factors, such as the organization of the work and staff behavior, influence air cleanliness. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Performance analysis of air conditioning system and airflow simulation in an operating theater

    Science.gov (United States)

    Alhamid, Muhammad Idrus; Budihardjo, Rahmat

    2018-02-01

    The importance of maintaining performance of a hospital operating theater is to establish an adequate circulation of clean air within the room. The parameter of air distribution in a space should be based on Air Changes per Hour (ACH) to maintain a positive room pressure. The dispersion of airborne particles in the operating theater was governed by regulating the air distribution so that the operating theater meets clean room standards ie ISO 14664 and ASHRAE 170. Here, we introduced several input parameters in a simulation environment to observe the pressure distribution in the room. Input parameters were air temperature, air velocity and volumetric flow rate entering and leaving room for existing and designed condition. In the existing operating theatre, several observations were found. It was found that the outlet air velocity at the HEPA filter above the operating table was too high thus causing a turbulent airflow pattern. Moreover, the setting temperature at 19°C was found to be too low. The supply of air into the room was observed at lower than 20 ACH which is under the standard requirement. Our simulation using FloVent 8.2™ program showed that not only airflow turbulence could be reduced but also the amount of particle contamination could also be minimized.

  19. Risk factors for persistent airflow limitation: Analysis of 306 patients with asthma

    OpenAIRE

    Wang, Lingcheng; Gao, Shuncui; Zhu, Wei; Su, Jun

    2014-01-01

    Objectives : To determine the risk factors associated with persistent airflow limitation in patients with asthma. Method s: This study was designed and carried out in the department of respiratory medicine, fourth People?s Hospital of Jinan City, Shandong province, China between Jan 2012 and Dec 2012. Three hundred and six asthma patients participating in the study were divided into persistent airflow limitation group (PAFL) and no persistent airflow limitation group (NPAFL). The patients par...

  20. Thermal performance of natural airflow window in subtropical and temperate climate zones - A comparative study

    International Nuclear Information System (INIS)

    Chow Tintai; Lin Zhang; Fong Kwongfai; Chan Lokshun; He Miaomiao

    2009-01-01

    Airflow window is highly useful in conserving building energy, and lessens the comfort problems caused by glazing. In this study, the thermal performance of a natural airflow window was examined through the use of a dynamic model, developed based on the integrated energy balance and airflow networks. The validity of the model was first tested by measured data obtained from a prototype installed at an environmental chamber. The application in the subtropical and temperate climate zones were then examined with the typical weather data of Hong Kong and Beijing. The findings confirmed that the natural airflow window can achieve substantial energy saving in both cities, and the reversible window frame is only required for Beijing, a location with hot summer and cold winter. The space cooling load via fenestration in Hong Kong, a subtropical city, can be reduced to 60% of the commonly used single absorptive glazing. In Beijing, as an example of the temperate climate, this can be reduced to 75% of the commonly used double glazing configuration in the summer period, and the space heat gain can be improved by 46% in the winter period.

  1. Computer simulation of airflow through a multi-generation tracheobronchial conducting airway

    Energy Technology Data Exchange (ETDEWEB)

    Fan, B.; Cheng, Yung-Sung; Yeh, Hsu-Chi

    1995-12-01

    Knowledge of airflow patterns in the human lung is important for an analysis of lung diseases and drug delivery of aerosolized medicine for medical treatment. However, very little systematic information is available on the pattern of airflow in the lung and on how this pattern affects the deposition of toxicants in the lung, and the efficacy of aerosol drug therapy. Most previous studies have only considered the airflow through a single bifurcating airway. However, the flow in a network of more than one bifurcation is more complicated due to the effect of interrelated lung generations. Because of the variation of airway geometry and flow condition from generation to generation, a single bifurcating airway cannot be taken as a representative for the others in different generations. The flow in the network varies significantly with airway generations because of a redistribution of axial momentum by the secondary flow motions. The influence of the redistribution of flow is expected in every generation. Therefore, a systematic information of the airflow through a multi-generation tracheobronchial conducting airway is needed, and it becomes the purpose of this study. This study has provided information on airflow in a lung model which is necessary to the study of the deposition of toxicants and therapeutic aerosols.

  2. Computer simulation of airflow through a multi-generation tracheobronchial conducting airway

    International Nuclear Information System (INIS)

    Fan, B.; Cheng, Yung-Sung; Yeh, Hsu-Chi.

    1995-01-01

    Knowledge of airflow patterns in the human lung is important for an analysis of lung diseases and drug delivery of aerosolized medicine for medical treatment. However, very little systematic information is available on the pattern of airflow in the lung and on how this pattern affects the deposition of toxicants in the lung, and the efficacy of aerosol drug therapy. Most previous studies have only considered the airflow through a single bifurcating airway. However, the flow in a network of more than one bifurcation is more complicated due to the effect of interrelated lung generations. Because of the variation of airway geometry and flow condition from generation to generation, a single bifurcating airway cannot be taken as a representative for the others in different generations. The flow in the network varies significantly with airway generations because of a redistribution of axial momentum by the secondary flow motions. The influence of the redistribution of flow is expected in every generation. Therefore, a systematic information of the airflow through a multi-generation tracheobronchial conducting airway is needed, and it becomes the purpose of this study. This study has provided information on airflow in a lung model which is necessary to the study of the deposition of toxicants and therapeutic aerosols

  3. Room Airflows with Low Reynolds Number Effects

    DEFF Research Database (Denmark)

    Topp, Claus; Nielsen, Peter V.; Davidson, Lars

    The behaviour of room airflows under fully turbulent conditions is well known both in terms of experiments and, numerical calculations by computational fluid dynamics (CFD). For room airflows where turbulence is not fully developed though, i.e. flows at low Reynolds numbers, the existing knowledge...... is limited. It has been the objective to investigate the behaviour of a plane isothermal wall jet in a full-scale ventilated room at low Reynolds numbers, i.e. when the flow is not fully turbulent. The results are significantly different from known theory for fully turbulent flows. It was found that the jet...... constants are a strong function of the Reynolds number up to a level of Reh≈500....

  4. Influence of furnishing on indoor airflow near external walls

    DEFF Research Database (Denmark)

    Mortensen, Lone Hedegaard; Rode, Carsten; Peuhkuri, Ruut

    2008-01-01

    Simulations of indoor environments in buildings are usually performed assuming uniform distribution of temperature and humidity of the indoor air, such as it would be in an idealised unfurnished room. The flow patterns near external walls may however be very different from the undisturbed airflow...... distributions, as the walls behind furniture may be colder than the other surroundings of the room, and the furniture to some extent obstructs the airflow. This paper describes an investigation of a room with a piece of furniture placed near an external wall. This was investigated using Particle Image...... Velocimetry (PIV) measurements. It was found how the pattern of airflow behind furniture placed near cold walls was influenced by the thickness of air gaps behind and below the furniture. But it was also found that even if the furniture was placed directly on the floor, there would be a considerable flow...

  5. Measurement of the resistivity of porous materials with an alternating air-flow method.

    Science.gov (United States)

    Dragonetti, Raffaele; Ianniello, Carmine; Romano, Rosario A

    2011-02-01

    Air-flow resistivity is a main parameter governing the acoustic behavior of porous materials for sound absorption. The international standard ISO 9053 specifies two different methods to measure the air-flow resistivity, namely a steady-state air-flow method and an alternating air-flow method. The latter is realized by the measurement of the sound pressure at 2 Hz in a small rigid volume closed partially by the test sample. This cavity is excited with a known volume-velocity sound source implemented often with a motor-driven piston oscillating with prescribed area and displacement magnitude. Measurements at 2 Hz require special instrumentation and care. The authors suggest an alternating air-flow method based on the ratio of sound pressures measured at frequencies higher than 2 Hz inside two cavities coupled through a conventional loudspeaker. The basic method showed that the imaginary part of the sound pressure ratio is useful for the evaluation of the air-flow resistance. Criteria are discussed about the choice of a frequency range suitable to perform simplified calculations with respect to the basic method. These criteria depend on the sample thickness, its nonacoustic parameters, and the measurement apparatus as well. The proposed measurement method was tested successfully with various types of acoustic materials.

  6. Reshaping of bulbar odor response by nasal flow rate in the rat.

    Directory of Open Access Journals (Sweden)

    Emmanuelle Courtiol

    2011-01-01

    Full Text Available The impact of respiratory dynamics on odor response has been poorly studied at the olfactory bulb level. However, it has been shown that sniffing in the behaving rodent is highly dynamic and varies both in frequency and flow rate. Bulbar odor response could vary with these sniffing parameter variations. Consequently, it is necessary to understand how nasal airflow can modify and shape odor response at the olfactory bulb level.To assess this question, we used a double cannulation and simulated nasal airflow protocol on anesthetized rats to uncouple nasal airflow from animal respiration. Both mitral/tufted cell extracellular unit activity and local field potentials (LFPs were recorded. We found that airflow changes in the normal range were sufficient to substantially reorganize the response of the olfactory bulb. In particular, cellular odor-evoked activities, LFP oscillations and spike phase-locking to LFPs were strongly modified by nasal flow rate.Our results indicate the importance of reconsidering the notion of odor coding as odor response at the bulbar level is ceaselessly modified by respiratory dynamics.

  7. Validity of peak expiratory flow measurement in assessing reversibility of airflow obstruction.

    Science.gov (United States)

    Dekker, F W; Schrier, A C; Sterk, P J; Dijkman, J H

    1992-01-01

    BACKGROUND: Assessing the reversibility of airflow obstruction by peak expiratory (PEF) measurements would be practicable in general practice, but its usefulness has not been investigated. METHODS: PEF measurements were performed (miniWright peak flow meter) in 73 general practice patients (aged 40 to 84) with a history of asthma or chronic obstructive lung disease before and after 400 micrograms inhaled sulbutamol. The change in PEF was compared with the change in forced expiratory volume in one second (FEV1). Reversible airflow obstruction was analysed in two ways according to previous criteria. When defined as a 9% or greater increase in FEV1 expressed as a percentage of predicted values reversibility was observed in 42% of patients. Relative operating characteristic analysis showed that an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (the sensitivity and specificity of an increase of 60 l/min in detecting a 9% or more increase in FEV1 as a percentage of predicted values were 68% and 93% respectively, with a positive predictive value of 87%). When defined as an increase of 190 ml or more in FEV1, reversible airflow obstruction was observed in 53% of patients. Again an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (sensitivity 56%, specificity 94%, and positive predictive value 92%). CONCLUSION: Absolute changes in PEF can be used as a simple technique to diagnose reversible airflow obstruction in patients from general practice. PMID:1519192

  8. Strongly coupled interaction between a ridge of fluid and an inviscid airflow

    KAUST Repository

    Paterson, C.; Wilson, S. K.; Duffy, B. R.

    2015-01-01

    ridge down near to its edges and to pull it up near to its middle. At a critical airflow strength, the upslope contact angle reaches the receding contact angle at which the upslope contact line de-pins, and continuing to increase the airflow strength

  9. Differentiating between adductor and abductor spasmodic dysphonia using airflow interruption

    Science.gov (United States)

    Hoffman, Matthew R.; Jiang, Jack J.; Rieves, Adam L.; McElveen, Kelsey A.B.; Ford, Charles N.

    2009-01-01

    Objective To measure the laryngeal resistance (RL), subglottal pressure (Ps), and mean flow rate (MFR) of adductor (ADSD) and abductor (ABSD) spasmodic dysphonia patients using the airflow interrupter. Methods The RL of six ABSD and seven ADSD patients was measured using the airflow interrupter, a noninvasive device designed to measure MFR and Ps via mechanical balloon valve interruption. Subjects performed ten trials at each of two intensity levels, with each trial consisting of a sustained /a/ during which phonation was interrupted for 500 ms. Laryngeal resistance was calculated as subglottal pressure divided by airflow. Results Mean RL for the ADSD and ABSD subtypes at 65 dB were 24.78 cmH2O/l/s and 14.51 cmH2O/l/s, respectively (p = 0.04). Mean RL at 70 dB were 40.02 cmH2O/l/s and 15.84 cmH2O/l/s (p = 0.014). Ps for the ADSD and ABSD subtypes at 65 dB were 10.23 cmH2O and 8.32 cmH2O, respectively (p = 0.582). At the 70 dB level, Ps were 12.39 cmH2O and 11.78 cmH2O (p = 0.886). MFR for the ADSD and ABSD subtypes at 65 dB were 435 ml/s and 746 ml/s (p = 0.205). Mean MFR at 70 dB were 518 ml/s and 848 ml/s (p = 0.198). Conclusion Noninvasive measurements of RL may be useful for differentiating between ADSD and ABSD. This simple objective test which produces a quantitative output could be used to evaluate laryngeal function in patients with spasmodic dysphonia. PMID:19554636

  10. Using Computational Fluid Dynamics to examine airflow characteristics in Empty Nose Syndrome

    Science.gov (United States)

    Flint, Tim; Esmaily-Moghadam, Mahdi; Thamboo, Andrew; Velasquez, Nathalia; Nayak, Jayakar V.; Sellier, Mathieu; Moin, Parviz

    2016-11-01

    The enigmatic disorder, empty nose syndrome (ENS), presents with a complex subjective symptom profile despite objectively patent nasal airways, and recent reports suggest that surgical augmentation of the nasal airway can improve quality of life and ENS-related complaints. In this study, computational fluid dynamics (CFD) was performed both prior to, and following, inferior turbinate augmentation to model the resultant changes in airflow patterns and better understand the pathophysiology of ENS. An ENS patient with marked reduction in ENS symptoms following turbinate augmentation was identified, and pre- and post-operative CT imaging was collected. A Finite element framework with the variational multiscale method (Esmaily-Moghadam, Comput. Methods Appl. Mech. Engrg. 2015) was used to compute the airflow, temperature, and moisture transport through the nasal cavity. Comparison of the CFD results following corrective surgery showed higher levels of airflow turbulence. Augmentation produced 50%, 25%, and 25% increases in root mean square pressure, wall shear stress, and heat flux respectively. These results provide insight into the changes in nasal airflow characteristics attainable through surgical augmentation, and by extension, how nasal airflow patterns may be distorted in the 'overly patent' airway of ENS patients. Supported by Stanford University CTR and Fulbright New Zealand.

  11. Occupational exposure to pesticides are associated with fixed airflow obstruction in middle-age.

    Science.gov (United States)

    Alif, Sheikh M; Dharmage, Shyamali C; Benke, Geza; Dennekamp, Martine; Burgess, John A; Perret, Jennifer L; Lodge, Caroline J; Morrison, Stephen; Johns, David Peter; Giles, Graham G; Gurrin, Lyle C; Thomas, Paul S; Hopper, John Llewelyn; Wood-Baker, Richard; Thompson, Bruce R; Feather, Iain H; Vermeulen, Roel; Kromhout, Hans; Walters, E Haydn; Abramson, Michael J; Matheson, Melanie Claire

    2017-11-01

    Population-based studies have found evidence of a relationship between occupational exposures and Chronic Obstructive Pulmonary Disease (COPD), but these studies are limited by the use of prebronchodilator spirometry. Establishing this link using postbronchodilator is critical, because occupational exposures are a modifiable risk factor for COPD. To investigate the associations between occupational exposures and fixed airflow obstruction using postbronchodilator spirometry. One thousand three hundred and thirty-five participants were included from 2002 to 2008 follow-up of the Tasmanian Longitudinal Health Study (TAHS). Spirometry was performed and lifetime work history calendars were used to collect occupational history. ALOHA plus Job Exposure Matrix was used to assign occupational exposure, and defined as ever exposed and cumulative exposure unit (EU)-years. Fixed airflow obstruction was defined by postbronchodilator FEV 1 /FVC biological dust (relative risk (RR)=1.58, 95% CI 1.01 to 2.48), pesticides (RR=1.74,95% CI 1.00 to 3.07) and herbicides (RR=2.09,95% CI 1.18 to 3.70) were associated with fixed airflow obstruction. Cumulative EU-years to all pesticides (RR=1.11,95% CI 1.00 to 1.25) and herbicides (RR=1.15,95% CI 1.00 to 1.32) were also associated with fixed airflow obstruction. In addition, all pesticides exposure was consistently associated with chronic bronchitis and symptoms that are consistent with airflow obstruction. Ever exposure to mineral dust, gases/fumes and vapours, gases, dust or fumes were only associated with fixed airflow obstruction in non-asthmatics only. Pesticides and herbicides exposures were associated with fixed airflow obstruction and chronic bronchitis. Biological dust exposure was also associated with fixed airflow obstruction in non-asthmatics. Minimising occupational exposure to these agents may help to reduce the burden of COPD. © Article author(s) (or their employer(s) unless otherwise stated in the text of the

  12. Impact of airflow interaction on inhaled air quality and transport of contaminants in rooms with personalized and total volume ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Cermak, Radim; Kovar, O.

    2003-01-01

    The impact of airflow interaction on inhaled air quality and transport of contaminants between occupants was studied in regard to pollution from floor covering, human bioeffluents and exhaled air, with combinations of two personalized ventilation systems (PV) with mixing and displacement...... quality with personalized and mixing ventilation was higher or at least similar compared to mixing ventilation alone. In the case of PV combined with displacement ventilation, the interaction caused mixing of the room air, an increase in the transport of bioeffluents and exhaled air between occupants and...... ventilation. In total, 80 L/s of clean air supplied at 20°C was distributed between the ventilation systems at different combinations of personalized airflow rate. Two breathing thermal manikins were used to simulate occupants in a full-scale test room. Regardless of the airflow interaction, the inhaled air...

  13. The effects of pen partitions and thermal pig simulators on airflow in a livestock test room

    DEFF Research Database (Denmark)

    Bjerg, B.; Svidt, Kjeld; Zhang, G.

    2000-01-01

    measurements and CFD simulations showed that the introduction of pen partitions and thermal pig simulators reduced the air velocities in the occupied zone of the test room. Detailed geometric modelling of the animals might often be unnecessary for simulation of airflow in livestock rooms. This will especially......The aim of this work was to investigate the influence of pen partitions and heated simulated pigs on airflow in a slot ventilated test room and to evaluate computer fluid dynamics (CFD) as a tool to predict airflow in livestock rooms. To obtain two-dimensional flow in the occupied zone, four...... guiding plates were mounted beneath the ceiling in the test room. Experiments were carried out in three arrangements: (a) the room with guiding plates; (b) the room with guiding plates and eight heated pig simulators; and (c) the room with guiding plates, eight heated pig simulators and 0.8 m high...

  14. Control of nasal vasculature and airflow resistance in the dog.

    Science.gov (United States)

    Lung, M A; Phipps, R J; Wang, J C; Widdicombe, J G

    1984-01-01

    Nasal vascular and airflow resistances have been measured in dogs, simultaneously on both sides separately. Vascular resistance was measured either by constant flow perfusion of the terminal branch of the maxillary artery (which supplies, via the sphenopalatine artery, the nasal septum, most of the turbinates and the nasal sinuses) or by measuring blood flow through this artery, maintained by the dog's own blood pressure. Airflow resistance was assessed by inserting balloon-tipped endotracheal catheters into the back of each nasal cavity via the nasopharynx, and measuring transnasal pressure at constant airflow through each side of the nose simultaneously. Preliminary experiments indicated that there was 5-10% collateral anastomosis between the two sides. Close-arterial injection of drugs showed different patterns of response. Adrenaline, phenylephrine, chlorpheniramine and low doses of prostaglandin F2 alpha increased vascular resistance and lowered airway resistance. Salbutamol, methacholine and histamine lowered vascular resistance and increased airway resistance. Dobutamine decreased airway resistance with a small increase in vascular resistance. Prostaglandins E1, E2 and F2 alpha (high dose) decreased both vascular and airway resistances. Substance P, eledoisin-related peptide and vasoactive intestinal polypeptide lowered vascular resistance with little change in airway resistance. The results are interpreted in terms of possible drug actions on precapillary resistance vessels, sinusoids and venules, and arteriovenous anastomoses. It is concluded that nasal airway resistance cannot be correlated with vascular resistance or blood flow, since the latter has a complex and ill-defined relationship with nasal vascular blood volume. PMID:6204040

  15. The efficacy of airflow and seat vibration on reducing visually induced motion sickness.

    Science.gov (United States)

    D'Amour, Sarah; Bos, Jelte E; Keshavarz, Behrang

    2017-09-01

    Visually induced motion sickness (VIMS) is a well-known sensation in virtual environments and simulators, typically characterized by a variety of symptoms such as pallor, sweating, dizziness, fatigue, and/or nausea. Numerous methods to reduce VIMS have been previously introduced; however, a reliable countermeasure is still missing. In the present study, the effect of airflow and seat vibration to alleviate VIMS was investigated. Eighty-two participants were randomly assigned to one of four groups (airflow, vibration, combined airflow and vibration, and control) and then exposed to a 15 min long video of a bicycle ride shot from first-person view. VIMS was measured using the Fast Motion Sickness Scale (FMS) and the Simulator Sickness Questionnaire (SSQ). Results showed that the exposure of airflow significantly reduced VIMS, whereas the presence of seat vibration, in contrast, did not have an impact on VIMS. Additionally, we found that females reported higher FMS scores than males, however, this sex difference was not found in the SSQ scores. Our findings demonstrate that airflow can be an effective and easy-to-apply technique to reduce VIMS in virtual environments and simulators, while vibration applied to the seat is not a successful method.

  16. Emphysema predicts hospitalisation and incident airflow obstruction among older smokers: a prospective cohort study.

    Directory of Open Access Journals (Sweden)

    David A McAllister

    Full Text Available Emphysema on CT is common in older smokers. We hypothesised that emphysema on CT predicts acute episodes of care for chronic lower respiratory disease among older smokers.Participants in a lung cancer screening study age ≥ 60 years were recruited into a prospective cohort study in 2001-02. Two radiologists independently visually assessed the severity of emphysema as absent, mild, moderate or severe. Percent emphysema was defined as the proportion of voxels ≤ -910 Hounsfield Units. Participants completed a median of 5 visits over a median of 6 years of follow-up. The primary outcome was hospitalization, emergency room or urgent office visit for chronic lower respiratory disease. Spirometry was performed following ATS/ERS guidelines. Airflow obstruction was defined as FEV1/FVC ratio <0.70 and FEV1<80% predicted.Of 521 participants, 4% had moderate or severe emphysema, which was associated with acute episodes of care (rate ratio 1.89; 95% CI: 1.01-3.52 adjusting for age, sex and race/ethnicity, as was percent emphysema, with similar associations for hospitalisation. Emphysema on visual assessment also predicted incident airflow obstruction (HR 5.14; 95% CI 2.19-21.1.Visually assessed emphysema and percent emphysema on CT predicted acute episodes of care for chronic lower respiratory disease, with the former predicting incident airflow obstruction among older smokers.

  17. Airflow attenuation and bed net utilization: observations from Africa and Asia

    DEFF Research Database (Denmark)

    von Seidlein, Lorenz; Ikonomidis, Konstantin; Bruun, Rasmus

    2012-01-01

    Background/Methods Qualitative studies suggest that bed nets affect the thermal comfort of users. To understand and reduce this discomfort the effect of bed nets on temperature, humidity, and airflow was measured in rural homes in Asia and Africa, as well as in an experimental wind tunnel. Two...... discomfort is a factor limiting bed net use and open a range of architectural possibilities to overcome this limitation. Keywords: Malaria; Bed nets; Africa; Tanzania; The Gambia; Asia; Thailand; Philippines; Airflow; Temperature; Humidity; Climate...... investigators with architectural training selected 60 houses in The Gambia, Tanzania, Philippines, and Thailand. Data-loggers were used to measure indoor temperatures in hourly intervals over a 12 months period. In a subgroup of 20 houses airflow, temperature and humidity were measured at five-minute intervals...

  18. Prevalence of airflow obstruction in patients with stable systolic heart failure

    DEFF Research Database (Denmark)

    Dalsgaard, Morten; Plesner, Louis Lind; Schou, Morten

    2017-01-01

    Background: Chronic obstructive pulmonary disease (COPD) is an important differential diagnosis in heart failure (HF). However, routine use of spirometry in outpatient HF clinics is not implemented. The aim of the present study was to determine the prevalence of both airflow obstruction and non...... failure clinics were examined with spirometry at their first visit and after optimal medical treatment for HF was achieved. airflow obstruction was classified and graded according to the GOLD 2011 revision. Results: Baseline spirometry was performed in 593 included patients and 71 (12%) had a clinical......%) had mild disease (GOLD I) and 180 (30%) patients had moderate to very severe disease (GOLD II-IV). No difference in spirometric variables was observed following up titration of medication. Conclusion: In stable patients with HF airflow obstruction is frequent and severely underdiagnosed. Spirometry...

  19. Harvesting energy from airflow with a michromachined piezoelectric harvester inside a Helmholtz resonator

    NARCIS (Netherlands)

    Matova, S.P.; Elfrink, R.; Vullers, R.J.M.; Schaijk, R. van

    2011-01-01

    In this paper we report an airflow energy harvester that combines a piezoelectric energy harvester with a Helmholtz resonator. The resonator converts airflow energy to air oscillations which in turn are converted into electrical energy by a piezoelectric harvester. Two Helmholtz resonators with

  20. Airflow Test of Acoustic Board Samples

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Jensen, Lise Mellergaard

    In the laboratory of Indoor Environmental Engineering, Department of Civil Engineering, Aalborg University an airflow test on 2x10 samples of acoustic board were carried out the 2nd of June 2012. The tests were carried out for Rambøll and STO AG. The test includes connected values of volume flow...

  1. AIRFLOW PATTERNS AND STACK PRESSURE SIMULATION IN A HIGH RISE RESIDENTIAL BUILDING LOCATED IN SEOUL

    Directory of Open Access Journals (Sweden)

    Khoukhi Maatouk

    2007-07-01

    Full Text Available Buoyancy forces due to air density difference between outdoor air and indoor air cause stack effect in high-rise buildings in cold climates. This stack effect occurs mainly at the core of the building such as the stairway and elevator shafts and causes many problems such as the energy loss caused by air flow, the blocked elevator door and discomfort due to inflowing of strong outdoor air. The main purpose of this work is to model the airflow pattern in a highrise building during the winter period by mean of COMIS. The presented building which is situated in Korea contains 30 floors above the ground level and 5 basement floors. Using COMIS, the simulation has been carried out for the entire building. However, the simulation failed due to the huge number of zones and interactions between them. Therefore, a model of building which contains 14 floors with 5 floors in the basement has been considered; and a simplified model based on the considered one has been constructed and compared with the 14 floors model. The simplified model consists on reducing the number of floors by combining a certain number of stories into one so that to enable the simulation to be carried on with a minimum number of zones and links. The result of the simulation shows that this approach could be used with accuracy still being satisfied. Therefore, the simplified procedure has been extended and applied to the high rise building model with 30 stories above the ground level and 5 stories in the basement. The effect of the exterior wall air-tightness of the building with 30 stories on the stack pressure and airflow by infiltration and/or by exfiltration has been investigated. The result shows that the total air by infiltration and/or exfiltration within the elevator shafts increases with the decrease of the level of the air-tightness of the exterior wall of the building. It has been also shown that a huge amount of air infiltrates through the shuttle and emergency elevator

  2. Integrated building (and) airflow simulation: an overview

    NARCIS (Netherlands)

    Hensen, J.L.M.

    2002-01-01

    This paper aims to give a broad overview of building airflow simulation, and advocates that the essential ingredients for quality assurance are: domain knowledge; selection of appropriate level of resolution; calibration and validation; and a correct performance assessment methodology. Directions

  3. Experimental investigation into heating and airflow in trombe walls and solar chimneys

    International Nuclear Information System (INIS)

    Habib, A.; Burek, S.

    2006-01-01

    Trombe Walls and solar chimneys are examples of passive solar air heating systems. However, the airflow and thermal efficiency characteristics of this type of system are not well understood, and partly for this reason, they are not commonly utilised. This paper reports on an experimental investigation into buoyancy-driven convection in a test rig designed to simulate the operation of a passive solar collector. The test rig comprised a vertical open-ended channel, approximately 1a square, heated from one side. The channel depth could be varied from 20mm to 110mm, and heating inputs varied from 200W to 1000W. Temperatures and airflow rates were measured and recorded, to characterise both steady-state and transient performance. The principal findings are: 1. Time constants (for heating)ranged typically between 30 and 70 minutes. 2. Flow regimes were mainly laminar (Reynolds number varing from ∼500 to ∼4000, depending on heat input and channel depth. 3. The thermal efficiency (as a solar collector and the heat transfer coefficient were functions of heat input, and were not depended on the channel depth. 4. The mass flow rate through the channel increased bath as the heat input increased and as the channel depth increased. The paper presents these findings and discusses their implications in more detail.(Author)

  4. Airway wall thickness associated with forced expiratory volume in 1 second decline and development of airflow limitation

    NARCIS (Netherlands)

    Hoesein, Firdaus A. A. Mohamed; de Jong, Pim A.; Lammers, Jan-Willem J.; Mali, Willem P. T. M.; Schmidt, Michael; de Koning, Harry J.; van der Aalst, Carlijn; Oudkerk, Matthijs; Vliegenthart, Rozemarijn; Groen, Harry J. M.; van Ginneken, Bram; van Rikxoort, Eva M.; Zanen, Pieter

    Airway wall thickness and emphysema contribute to airflow limitation. We examined their association with lung function decline and development of airflow limitation in 2021 male smokers with and without airflow limitation. Airway wall thickness and emphysema were quantified on chest computed

  5. Thermal sensation and comfort during exposure to local airflow to face or legs.

    Science.gov (United States)

    Yamashita, Kazuaki; Matsuo, Juntaro; Tochihara, Yutaka; Kondo, Youichiro; Takayama, Shizuka; Nagayama, Hiroki

    2005-01-01

    The present study examined the contribution of local airflow temperature to thermal sensation and comfort in humans. Eight healthy male students were exposed to local airflow to their faces (summer condition) or legs (winter condition) for 30 minutes. Local airflow temperature (Tf) was maintained at 18 degrees C to 36 degrees C, and ambient temperature (Ta) was maintained at 17.4 degrees C to 31.4 degrees C. Each subject was exposed to 16 conditions chosen from the combination of Tf and Ta. Based on the results of multiple regression analysis, the standardized partial regression coefficient of Tf and Ta were determined to be 0.93 and 0.13 in the summer condition, and 0.71 and 0.36 in the winter condition at the end of the exposure. Also, thermal comfort was observed to depend closely on the interrelation between Tf and Ta. The present data suggested that local airflow temperature is an important thermal factor regarding thermal sensation and comfort.

  6. Proportion and clinical characteristics of non-asthmatic non-smokers among adults with airflow obstruction.

    Directory of Open Access Journals (Sweden)

    Hiroto Takiguchi

    Full Text Available Chronic obstructive pulmonary disease (COPD mainly develops after long-term exposure to cigarette or biomass fuel smoke, but also occurs in non-smokers with or without a history of asthma. We investigated the proportion and clinical characteristics of non-smokers among middle-aged to elderly subjects with airflow obstruction.We retrospectively analyzed 1,892 subjects aged 40-89 years who underwent routine preoperative spirometry at a tertiary university hospital in Japan. Airflow obstruction was defined as a forced expiratory volume in 1 second (FEV1/forced vital capacity < 0.7 or as the lower limit of the normal.Among 323 patients presenting with FEV1/forced vital capacity < 0.7, 43 had asthma and 280 did not. Among the non-asthmatic patients with airflow obstruction, 94 (34% were non-smokers. A larger number of women than men with airflow obstruction had asthma (26% vs. 7.6%, p < 0.001, or were non-smokers among non-asthmatics (72% vs. 20%, p < 0.001. Non-asthmatic non-smokers, rather than non-asthmatic smokers, asthmatic non-smokers, and asthmatic smokers, exhibited better pulmonary function (median FEV1: 79% of predicted FEV1 vs. 73%, 69%, and 66%, respectively, p = 0.005 and less dyspnea on exertion (1% vs. 12%, 12%, and 28%, respectively, p = 0.001. Pulmonary emphysema on thoracic computed tomography was less common in non-smokers (p < 0.001. Using the lower limit of the normal to define airflow obstruction yielded similar results.There are a substantial number of non-smokers with airflow obstruction compatible with COPD in Japan. In this study, airflow obstruction in non-smokers was more common in women and likelier to result in mild functional and pathological abnormalities than in smokers. Further studies are warranted to investigate the long-term prognosis and appropriate management of this population in developed countries, especially in women.

  7. Airflow resistivity instrument for in situ measurement on the earth's ground surface

    Science.gov (United States)

    Zuckerwar, A. J.

    1983-01-01

    An airflow resistivity instrument features a novel specimen holder, especially designed for in situ measurement on the earth's ground surface. This capability eliminates the disadvantages of prior intrusive instruments, which necessitate the removal of a test specimen from the ground. A prototype instrument can measure airflow resistivities in the range 10-5000 cgs rayl/cm, at specimen depths up to 15.24 cm (6 in.), and at differential pressures up to 2490.8 dyn sq cm (1 in. H2O) across the specimen. Because of the close relationship between flow resistivity and acoustic impedance, this instrument should prove useful in acoustical studies of the earth's ground surface. Results of airflow resistivity measurements on an uncultivated grass field for varying values of moisture content are presented.

  8. Prevalence of asthma with airflow limitation, COPD, and COPD with variable airflow limitation in older subjects in a general Japanese population: the Hisayama Study.

    Science.gov (United States)

    Matsumoto, Koichiro; Seki, Nanae; Fukuyama, Satoru; Moriwaki, Atsushi; Kan-o, Keiko; Matsunaga, Yuko; Noda, Naotaka; Yoshida, Makoto; Koto, Hiroshi; Takata, Shohei; Nakanishi, Yoichi; Kiyohara, Yutaka; Inoue, Hiromasa

    2015-01-01

    Elucidating the prevalence of asthma and chronic obstructive pulmonary disease (COPD) is important for designing a public health strategy. Recent studies have discriminated a phenotype of COPD with variable airflow limitation (COPD-VAL) associated with asthma-COPD overlap syndrome. Its prevalence remains uncertain. The age and occupational distributions in the town of Hisayama and in Japan are nearly identical. Each disease's prevalence was estimated for the town's residents. In 2008, town residents (≥ 40 years) were solicited to participate in a health checkup. Individuals with abnormal spirometry (forced expiratory volume in 1s/forced vital capacity [FEV1/FVC]fashion reviewed their medical records, including bronchodilator reversibility. Individuals with airflow limitation were classified as having asthma, COPD, COPD-VAL, or other diseases. The prevalence of each disease was then estimated. A total of 2100 residents (43.4% of residents in the age group) completed spirometry. In 455 residents with abnormal spirometry, 190 residents had further evaluations, and the medical records of 174 residents were reviewed. The prevalence of asthma with airflow limitation, COPD, and COPD-VAL, were 2.0%, 8.4%, and 0.9%, respectively. The prevalence of COPD and COPD-VAL were higher in men and smokers than in women and never-smokers. The prevalence of COPD, but not COPD-VAL or asthma, increased with age. The prevalence of asthma with airflow limitation, COPD, and COPD-VAL were estimated in a population of residents (≥ 40 years) in Hisayama. Copyright © 2014 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  9. Proportion and clinical characteristics of non-asthmatic non-smokers among adults with airflow obstruction.

    Science.gov (United States)

    Takiguchi, Hiroto; Takeuchi, Tomoe; Niimi, Kyoko; Tomomatsu, Hiromi; Tomomatsu, Katsuyoshi; Hayama, Naoki; Oguma, Tsuyoshi; Aoki, Takuya; Urano, Tetsuya; Asai, Satomi; Miyachi, Hayato; Asano, Koichiro

    2018-01-01

    Chronic obstructive pulmonary disease (COPD) mainly develops after long-term exposure to cigarette or biomass fuel smoke, but also occurs in non-smokers with or without a history of asthma. We investigated the proportion and clinical characteristics of non-smokers among middle-aged to elderly subjects with airflow obstruction. We retrospectively analyzed 1,892 subjects aged 40-89 years who underwent routine preoperative spirometry at a tertiary university hospital in Japan. Airflow obstruction was defined as a forced expiratory volume in 1 second (FEV1)/forced vital capacity non-asthmatic patients with airflow obstruction, 94 (34%) were non-smokers. A larger number of women than men with airflow obstruction had asthma (26% vs. 7.6%, p non-smokers among non-asthmatics (72% vs. 20%, p Non-asthmatic non-smokers, rather than non-asthmatic smokers, asthmatic non-smokers, and asthmatic smokers, exhibited better pulmonary function (median FEV1: 79% of predicted FEV1 vs. 73%, 69%, and 66%, respectively, p = 0.005) and less dyspnea on exertion (1% vs. 12%, 12%, and 28%, respectively, p = 0.001). Pulmonary emphysema on thoracic computed tomography was less common in non-smokers (p non-smokers with airflow obstruction compatible with COPD in Japan. In this study, airflow obstruction in non-smokers was more common in women and likelier to result in mild functional and pathological abnormalities than in smokers. Further studies are warranted to investigate the long-term prognosis and appropriate management of this population in developed countries, especially in women.

  10. Finite Element Modeling of Airflow During Phonation

    Czech Academy of Sciences Publication Activity Database

    Šidlof, P.; Lunéville, E.; Chambeyron, C.; Doaré, O.; Chaigne, A.; Horáček, Jaromír

    2010-01-01

    Roč. 4, č. 1 (2010), s. 121-132 ISSN 1802-680X R&D Projects: GA AV ČR KJB200760801 Institutional research plan: CEZ:AV0Z20760514 Keywords : vocal fold s * airflow * numerical modeling * ALE * flow separation Subject RIV: BI - Acoustics

  11. Difference in airflow obstruction between Hispanic and non-Hispanic White female smokers.

    Science.gov (United States)

    Sood, Akshay; Stidley, Christine A; Picchi, Maria A; Celedón, Juan C; Gilliland, Frank; Crowell, Richard E; Belinsky, Steven A; Tesfaigzi, Yohannes

    2008-10-01

    Smoking-related respiratory diseases are a major cause of morbidity and mortality. However, the relationship between smoking and respiratory disease has not been well-studied among ethnic minorities in general and among women in particular. The objective of this cross-sectional study was to evaluate the risk of airflow obstruction and to assess lung function among Hispanic and non-Hispanic White (NHW) female smokers in a New Mexico cohort. Participants completed a questionnaire detailing smoking history and underwent spirometry testing. Outcomes studied included airflow obstruction, selected lung function parameters, and chronic mucus hyper-secretion. Chi square, logistic, and linear regression techniques were utilized. Of the 1,433 eligible women participants, 248 (17.3%) were Hispanic; and 319 had airflow obstruction (22.3%). Hispanic smokers were more likely to be current smokers, and report lower pack-years of smoking, compared to NHW smokers (p smokers were at a reduced risk of airflow obstruction compared to NHW smokers, with an O.R. of 0.51, 95% C.I. 0.34, 0.78 (p = 0.002) after adjustment for age, BMI, pack-years and duration of smoking, and current smoking status. Following adjustment for covariates, Hispanic smokers also had a higher mean absolute and percent predicted post-bronchodilator FEV(1)/FVC ratio, as well as higher mean percent predicted FEV(1) (p smokers in this New Mexico-based cohort had lower risk of airflow obstruction and better lung function than NHW female smokers. Further, smoking history did not completely explain these associations.

  12. Bacterial burden in the operating room: impact of airflow systems.

    Science.gov (United States)

    Hirsch, Tobias; Hubert, Helmine; Fischer, Sebastian; Lahmer, Armin; Lehnhardt, Marcus; Steinau, Hans-Ulrich; Steinstraesser, Lars; Seipp, Hans-Martin

    2012-09-01

    Wound infections present one of the most prevalent and frequent complications associated with surgical procedures. This study analyzes the impact of currently used ventilation systems in the operating room to reduce bacterial contamination during surgical procedures. Four ventilation systems (window-based ventilation, supported air nozzle canopy, low-turbulence displacement airflow, and low-turbulence displacement airflow with flow stabilizer) were analyzed. Two hundred seventy-seven surgical procedures in 6 operating rooms of 5 different hospitals were analyzed for this study. Window-based ventilation showed the highest intraoperative contamination (13.3 colony-forming units [CFU]/h) followed by supported air nozzle canopy (6.4 CFU/h; P = .001 vs window-based ventilation) and low-turbulence displacement airflow (3.4 and 0.8 CFU/h; P system showed no increase of contamination in prolonged durations of surgical procedures. This study shows that intraoperative contamination can be significantly reduced by the use of adequate ventilation systems. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  13. Proportion and clinical characteristics of non-asthmatic non-smokers among adults with airflow obstruction

    Science.gov (United States)

    Takiguchi, Hiroto; Takeuchi, Tomoe; Niimi, Kyoko; Tomomatsu, Hiromi; Tomomatsu, Katsuyoshi; Hayama, Naoki; Oguma, Tsuyoshi; Urano, Tetsuya; Asai, Satomi; Miyachi, Hayato; Asano, Koichiro

    2018-01-01

    Background and objectives Chronic obstructive pulmonary disease (COPD) mainly develops after long-term exposure to cigarette or biomass fuel smoke, but also occurs in non-smokers with or without a history of asthma. We investigated the proportion and clinical characteristics of non-smokers among middle-aged to elderly subjects with airflow obstruction. Methods We retrospectively analyzed 1,892 subjects aged 40–89 years who underwent routine preoperative spirometry at a tertiary university hospital in Japan. Airflow obstruction was defined as a forced expiratory volume in 1 second (FEV1)/forced vital capacity non-asthmatic patients with airflow obstruction, 94 (34%) were non-smokers. A larger number of women than men with airflow obstruction had asthma (26% vs. 7.6%, p non-smokers among non-asthmatics (72% vs. 20%, p Non-asthmatic non-smokers, rather than non-asthmatic smokers, asthmatic non-smokers, and asthmatic smokers, exhibited better pulmonary function (median FEV1: 79% of predicted FEV1 vs. 73%, 69%, and 66%, respectively, p = 0.005) and less dyspnea on exertion (1% vs. 12%, 12%, and 28%, respectively, p = 0.001). Pulmonary emphysema on thoracic computed tomography was less common in non-smokers (p non-smokers with airflow obstruction compatible with COPD in Japan. In this study, airflow obstruction in non-smokers was more common in women and likelier to result in mild functional and pathological abnormalities than in smokers. Further studies are warranted to investigate the long-term prognosis and appropriate management of this population in developed countries, especially in women. PMID:29742176

  14. Characterization of Pump-Induced Acoustics in Space Launch System Main Propulsion System Liquid Hydrogen Feedline Using Airflow Test Data

    Science.gov (United States)

    Eberhart, C. J.; Snellgrove, L. M.; Zoladz, T. F.

    2015-01-01

    High intensity acoustic edgetones located upstream of the RS-25 Low Pressure Fuel Turbo Pump (LPFTP) were previously observed during Space Launch System (STS) airflow testing of a model Main Propulsion System (MPS) liquid hydrogen (LH2) feedline mated to a modified LPFTP. MPS hardware has been adapted to mitigate the problematic edgetones as part of the Space Launch System (SLS) program. A follow-on airflow test campaign has subjected the adapted hardware to tests mimicking STS-era airflow conditions, and this manuscript describes acoustic environment identification and characterization born from the latest test results. Fluid dynamics responsible for driving discrete excitations were well reproduced using legacy hardware. The modified design was found insensitive to high intensity edgetone-like discretes over the bandwidth of interest to SLS MPS unsteady environments. Rather, the natural acoustics of the test article were observed to respond in a narrowband-random/mixed discrete manner to broadband noise thought generated by the flow field. The intensity of these responses were several orders of magnitude reduced from those driven by edgetones.

  15. Harvesting energy from airflow with a michromachined piezoelectric harvester inside a Helmholtz resonator

    International Nuclear Information System (INIS)

    Matova, S P; Elfrink, R; Vullers, R J M; Van Schaijk, R

    2011-01-01

    In this paper we report an airflow energy harvester that combines a piezoelectric energy harvester with a Helmholtz resonator. The resonator converts airflow energy to air oscillations which in turn are converted into electrical energy by a piezoelectric harvester. Two Helmholtz resonators with adjustable resonance frequencies have been designed—one with a solid bottom and one with membrane on the bottom. The resonance frequencies of the resonators were matched to the complementing piezoelectric harvesters during harvesting. The aim of the presented work is a feasibility study on using packaged piezoelectric energy harvesters with Helmholtz resonators for airflow energy harvesting. The maximum energy we were able to obtain was 42.2 µW at 20 m s −1

  16. The incompressibility assumption in computational simulations of nasal airflow.

    Science.gov (United States)

    Cal, Ismael R; Cercos-Pita, Jose Luis; Duque, Daniel

    2017-06-01

    Most of the computational works on nasal airflow up to date have assumed incompressibility, given the low Mach number of these flows. However, for high temperature gradients, the incompressibility assumption could lead to a loss of accuracy, due to the temperature dependence of air density and viscosity. In this article we aim to shed some light on the influence of this assumption in a model of calm breathing in an Asian nasal cavity, by solving the fluid flow equations in compressible and incompressible formulation for different ambient air temperatures using the OpenFOAM package. At low flow rates and warm climatological conditions, similar results were obtained from both approaches, showing that density variations need not be taken into account to obtain a good prediction of all flow features, at least for usual breathing conditions. This agrees with most of the simulations previously reported, at least as far as the incompressibility assumption is concerned. However, parameters like nasal resistance and wall shear stress distribution differ for air temperatures below [Formula: see text]C approximately. Therefore, density variations should be considered for simulations at such low temperatures.

  17. An analysis of heat removal during cryogen spray cooling and effects of simultaneous airflow application.

    Science.gov (United States)

    Torres, J H; Tunnell, J W; Pikkula, B M; Anvari, B

    2001-01-01

    Cryogen spray cooling (CSC) is a method used to protect the epidermis from non-specific thermal injury that may occur as a result of various dermatological laser procedures. However, better understanding of cryogen deposition and skin thermal response to CSC is needed to optimize the technique. Temperature measurements and video imaging were carried out on an epoxy phantom as well as human skin during CSC with and without simultaneous application of airflow which was intended to accelerate cryogen evaporation from the substrate surface. An inverse thermal conduction model was used to estimate heat flux and total heat removed. Lifetime of the cryogen film deposited on the surface of skin and epoxy phantom lasted several hundred milliseconds beyond the spurt, but could be reduced to the spurt duration by application of airflow. Values over 100 J/cm(3) were estimated for volumetric heat removed from the epidermis using CSC. "Film cooling" instead of "evaporative cooling" appears to be the dominant mode of CSC on skin. Estimated values of heat removed from the epidermis suggest that a cryogen spurt as long as 200 milliseconds is required to counteract heat generated by high laser fluences (e.g., in treatment of port wine stains) in patients with high concentration of epidermal melanin. Additional cooling beyond spurt termination can be avoided by simultaneous application of airflow, although it is unclear at the moment if avoiding the additional cooling would be beneficial in the actual clinical situation. Copyright 2001 Wiley-Liss, Inc.

  18. Beach-dune dynamics: Spatio-temporal patterns of aeolian sediment transport under complex offshore airflow

    Science.gov (United States)

    Lynch, K.; Jackson, D.; Delgado-Fernandez, I.; Cooper, J. A.; Baas, A. C.; Beyers, M.

    2010-12-01

    This study examines sand transport and wind speed across a beach at Magilligan Strand, Northern Ireland, under offshore wind conditions. Traditionally the offshore component of local wind regimes has been ignored when quantifying beach-dune sediment budgets, with the sheltering effect of the foredune assumed to prohibit grain entrainment on the adjoining beach. Recent investigations of secondary airflow patterns over coastal dunes have suggested this may not be the case, that the turbulent nature of the airflow in these zones enhances sediment transport potential. Beach sediment may be delivered to the dune toe by re-circulating eddies under offshore winds in coastal areas, which may explain much of the dynamics of aeolian dunes on coasts where the dominant wind direction is offshore. The present study investigated aeolian sediment transport patterns under an offshore wind event. Empirical data were collected using load cell traps, for aeolian sediment transport, co-located with 3-D ultrasonic anemometers. The instrument positioning on the sub-aerial beach was informed by prior analysis of the airflow patterns using computational fluid dynamics. The array covered a total beach area of 90 m alongshore by 65 m cross-shore from the dune crest. Results confirm that sediment transport occurred in the ‘sheltered’ area under offshore winds. Over short time and space scales the nature of the transport is highly complex; however, preferential zones for sand entrainment may be identified. Alongshore spatial heterogeneity of sediment transport seems to show a relationship to undulations in the dune crest, while temporal and spatial variations may also be related to the position of the airflow reattachment zone. These results highlight the important feedbacks between flow characteristics and transport in a complex three dimensional surface.

  19. Clinically remitted childhood asthma is associated with airflow obstruction in middle-aged adults.

    Science.gov (United States)

    Omori, Keitaro; Iwamoto, Hiroshi; Yamane, Takashi; Nakashima, Taku; Haruta, Yoshinori; Hattori, Noboru; Yokoyama, Akihito; Kohno, Nobuoki

    2017-01-01

    While adult asthma has been shown to be a risk factor for COPD, the effect of remitted childhood asthma on adult lung function has not been clarified. The aim of this study was to examine whether remitted childhood asthma is a risk factor for airflow obstruction in a middle-aged general population. A total of 9896 participants (range: 35-60 years) from five healthcare centres were included in the study. The participants were classified into four categories based on the presence or absence of physician-diagnosed childhood/adulthood asthma and asthma symptoms as follows: healthy controls (n = 9154), remitted childhood asthma (n = 287), adulthood-onset asthma (n = 354) and childhood-adulthood asthma (n = 101). The prevalence of respiratory symptoms was similar in both the participants with remitted childhood asthma and healthy controls. The prevalence of airflow obstruction (forced expiratory volume in 1 s (FEV 1 )/forced vital capacity (FVC) childhood asthma, those with adult-onset asthma and those with childhood-adulthood asthma (5.2%, 14.4% and 16.8%, respectively) compared with healthy controls (2.2%). Multivariate logistic regression showed that remitted childhood asthma was independently associated with airflow obstruction. Among the participants with remitted childhood asthma, ever-smokers had significantly lower FEV 1 /FVC than never-smokers. Clinically remitted childhood asthma is associated with airflow obstruction in middle-aged adults. Smoking and remitted childhood asthma may be additive factors for the development of airflow obstruction. © 2016 Asian Pacific Society of Respirology.

  20. Is there any relationship between right and left hand dominance and right and left nasal airflow dominance?

    Science.gov (United States)

    Price, A; Eccles, R

    2017-10-01

    Left- or right-handedness is a common human trait, and it has been previously reported that human nasal airflow dominance correlates with hand dominance. Any relationship between hand dominance and nasal airflow dominance would be unusual. This study aimed to measure nasal airflow and look for any relationship to handedness. The modified Glatzel mirror was used to record the dominant nasal passage at 15-minute intervals over a 6-hour period in 29 healthy participants consisting of 15 left-handers and 14 right-handers. In left-handers, the percentage of time that the left nasal passage was dominant ranged from 0 to 100 per cent. In right-handers, the percentage of time that the right nasal passage was dominant ranged from 4.2 to 95.8 per cent. No correlation between nasal airflow dominance and hand dominance was identified. The results do not support the hypothesis that nasal airflow and handedness are related.

  1. Airflow resistivity of models of fibrous acoustic materials

    DEFF Research Database (Denmark)

    Tarnow, Viggo

    1996-01-01

    A new way of calculating the airflow resistivity of randomly placed parallel cylinders is presented. The calculation is based on Voronoi polygons, and the resistivity is given by the mean spacing between the fibers, their diameters, and the physical properties of air. New explicit formulas...

  2. CFD modelling and wind tunnel validation of airflow through plant canopies using 3D canopy architecture

    International Nuclear Information System (INIS)

    Endalew, A. Melese; Hertog, M.; Delele, M.A.; Baetens, K.; Persoons, T.; Baelmans, M.; Ramon, H.; Nicolai, B.M.; Verboven, P.

    2009-01-01

    The efficiency of pesticide application to agricultural fields and the resulting environmental contamination highly depend on atmospheric airflow. A computational fluid dynamics (CFD) modelling of airflow within plant canopies using 3D canopy architecture was developed to understand the effect of the canopy to airflow. The model average air velocity was validated using experimental results in a wind tunnel with two artificial model trees of 24 cm height. Mean air velocities and their root mean square (RMS) values were measured on a vertical plane upstream and downstream sides of the trees in the tunnel using 2D hotwire anemometer after imposing a uniform air velocity of 10 m s -1 at the inlet. 3D virtual canopy geometries of the artificial trees were modelled and introduced into a computational fluid domain whereby airflow through the trees was simulated using Reynolds-Averaged Navier-Stokes (RANS) equations and k-ε turbulence model. There was good agreement of the average longitudinal velocity, U between the measurements and the simulation results with relative errors less than 2% for upstream and 8% for downstream sides of the trees. The accuracy of the model prediction for turbulence kinetic energy k and turbulence intensity I was acceptable within the tree height when using a roughness length (y 0 = 0.02 mm) for the surface roughness of the tree branches and by applying a source model in a porous sub-domain created around the trees. The approach was applied for full scale orchard trees in the atmospheric boundary layer (ABL) and was compared with previous approaches and works. The simulation in the ABL was made using two groups of full scale orchard trees; short (h = 3 m) with wider branching and long (h = 4 m) with narrow branching. This comparison showed good qualitative agreements on the vertical profiles of U with small local differences as expected due to the spatial disparities in tree architecture. This work was able to show airflow within and above the

  3. Development of an Indoor Airflow Energy Harvesting System for Building Environment Monitoring

    Directory of Open Access Journals (Sweden)

    Fei Fei

    2014-05-01

    Full Text Available Wireless sensor networks (WSNs have been widely used for intelligent building management applications. Typically, indoor environment parameters such as illumination, temperature, humidity and air quality are monitored and adjusted by an intelligent building management system. However, owing to the short life-span of the batteries used at the sensor nodes, the maintenance of such systems has been labor-intensive and time-consuming. This paper discusses a battery-less self-powering system that converts the mechanical energy from the airflow in ventilation ducts into electrical energy. The system uses a flutter energy conversion device (FECD capable of working at low airflow speeds while installed on the ventilation ducts inside of buildings. A power management strategy implemented with a circuit system ensures sufficient power for driving commercial electronic devices. For instance, the power management circuit is capable of charging a 1 F super capacitor to 2 V under ventilation duct airflow speeds of less than 3 m/s.

  4. Subglottal pressure, tracheal airflow, and intrinsic laryngeal muscle activity during rat ultrasound vocalization

    Science.gov (United States)

    2011-01-01

    Vocal production requires complex planning and coordination of respiratory, laryngeal, and vocal tract movements, which are incompletely understood in most mammals. Rats produce a variety of whistles in the ultrasonic range that are of communicative relevance and of importance as a model system, but the sources of acoustic variability were mostly unknown. The goal was to identify sources of fundamental frequency variability. Subglottal pressure, tracheal airflow, and electromyographic (EMG) data from two intrinsic laryngeal muscles were measured during 22-kHz and 50-kHz call production in awake, spontaneously behaving adult male rats. During ultrasound vocalization, subglottal pressure ranged between 0.8 and 1.9 kPa. Pressure differences between call types were not significant. The relation between fundamental frequency and subglottal pressure within call types was inconsistent. Experimental manipulations of subglottal pressure had only small effects on fundamental frequency. Tracheal airflow patterns were also inconsistently associated with frequency. Pressure and flow seem to play a small role in regulation of fundamental frequency. Muscle activity, however, is precisely regulated and very sensitive to alterations, presumably because of effects on resonance properties in the vocal tract. EMG activity of cricothyroid and thyroarytenoid muscle was tonic in calls with slow or no fundamental frequency modulations, like 22-kHz and flat 50-kHz calls. Both muscles showed brief high-amplitude, alternating bursts at rates up to 150 Hz during production of frequency-modulated 50-kHz calls. A differentiated and fine regulation of intrinsic laryngeal muscles is critical for normal ultrasound vocalization. Many features of the laryngeal muscle activation pattern during ultrasound vocalization in rats are shared with other mammals. PMID:21832032

  5. Climate chamber for environmentally controlled laboratory airflow experiments.

    Science.gov (United States)

    Even-Tzur, Nurit; Zaretsky, Uri; Grinberg, Orly; Davidovich, Tomer; Kloog, Yoel; Wolf, Michael; Elad, David

    2010-01-01

    Climate chambers have been widely used in in vitro and in vivo studies which require controlled environmental temperature and humidity conditions. This article describes a new desktop climate chamber that was developed for application of respiratory airflows on cultured nasal epithelial cells (NEC) under controlled temperature and humidity conditions. Flow experiments were performed by connecting the climate chamber to an airflow generator via a flow chamber with cultured NEC. Experiments at two controlled climate conditions, 25 degrees C and 40% relative humidity (RH) and 37 degrees C and 80%RH, were conducted to study mucin secretion from the cultures inresponse to the flow. The new climate chamber is a relatively simple and inexpensive apparatus which can easily be connected to any flow system for climate controlled flow experiments. This chamber can be easily adjusted to various in vitro experiments, as well as to clinical studies with animals or human subjects which require controlled climate conditions.

  6. Airflow characteristics and pollution distribution around a thermal manikin - Impact of specific personal and indoor environmental factors

    DEFF Research Database (Denmark)

    Licina, Dusan; Tham, Kwok Wai; Melikov, Arsen Krikor

    2016-01-01

    , and ventilation flow considerably affected airflow characteristics and pollution distribution around the thermal manikin. Under the specific set of conditions studied, the most favorable airflow patterns in preventing the feet pollution from reaching the breathing zone was transverse flow from the front......This study presents a summary of experimental measurements on the airflow characteristics and pollution distribution around a non-breathing thermal manikin. The two objectives are: (1) to examine the extent to which personal (body posture, clothing insulation, table positioning) and environmental...... factors (room air temperature and ventilation flow) affect the airflow characteristic (velocity and temperature) around the thermal manikin and (2) to examine the pollution distribution within the convective boundary layer (CBL) around a thermal manikin and personal exposure to two types of airborne...

  7. Majority of never-smokers with airflow limitation do not have asthma: the Copenhagen General Population Study.

    Science.gov (United States)

    Çolak, Yunus; Afzal, Shoaib; Nordestgaard, Børge G; Lange, Peter

    2016-07-01

    A substantial proportion of individuals with airflow limitation are never-smokers. However, whether never-smokers with airflow limitation have undiagnosed asthma is unknown. We hypothesised that the majority of never-smokers with respiratory symptoms and airflow limitation but without known asthma have undiagnosed asthma by comparing characteristics and prognosis in never-smokers with airflow limitation and asthma (NS+AFL+A) with never-smokers with airflow limitation but without asthma (NS+AFL-A). Among 94 079 participants aged 20-100 years from the general population, 39 102 (42%) were never-smokers. In this group, 13 719 (35%) reported to have respiratory symptoms of whom 1610 (12%) had airflow limitation. We investigated characteristics and risk of complications (asthma or COPD exacerbations, pneumonias and all-cause mortality) and comorbidities (lung cancer, ischaemic heart disease, myocardial infarction, deep venous thrombosis and PE) during 4.5 years median follow-up. NS+AFL-A compared with NS+AFL+A reported less allergy and respiratory symptoms, and had higher FEV1 and lower levels of eosinophils and IgE in peripheral blood. NS+AFL+A had increased risk of asthma and COPD exacerbations, but not of pneumonias; adjusted HRs in NS+AFL+A compared with NS+AFL-A were 16 (95% CI 3.7 to 73) for asthma exacerbations and 15 (2.8 to 80) for COPD exacerbations. Still, NS+AFL-A had increased risk of COPD exacerbations and pneumonias, but not of asthma exacerbations; adjusted HRs in NS+AFL-A compared with never-smokers without airflow limitation or asthma (NS-AFL-A) were 7.7 (2.8 to 21) for COPD exacerbations and 1.7 (1.3 to 2.3) for pneumonias. Risk of comorbidities or all-cause mortality was not increased in NS+AFL-A or NS+AFL+A compared with NS-AFL-A. Majority of NS+AFL-A do not seem to have undiagnosed asthma and may instead have airflow limitation caused by other risk factors. Published by the BMJ Publishing Group Limited. For permission to use (where not

  8. Experimental and modelling study of the effect of airflow orientation with respect to strip electrode on ozone production of surface dielectric barrier discharge

    Science.gov (United States)

    Mikeš, J.; Pekárek, S.; Soukup, I.

    2016-11-01

    This study examines the effect of airflow orientation with respect to the strip active electrode on concentration of ozone and nitrogen dioxide produced in a planar generator based on the surface dielectric barrier discharge. The orientation of the airflow was tested in parallel and perpendicular with respect to the strips. It was found that in the investigated range of average discharge power, the ozone concentration increases approximately by 25% when airflow was oriented in parallel with respect to the strips in comparison with perpendicular orientation of the airflow. Similarly the increase of nitrogen dioxide concentration was observed for parallel orientation of the airflow with respect to the strips in comparison with the perpendicular orientation of the airflow. Within the range of wavelengths from 250 to 1100 nm, the changes of intensities of spectral lines associated with airflow orientation have been observed. A 3D numerical model describing ion trajectories and airflow patterns have also been developed.

  9. Pulmonary anatomy in the Nile crocodile and the evolution of unidirectional airflow in Archosauria

    Directory of Open Access Journals (Sweden)

    Emma R. Schachner

    2013-03-01

    Full Text Available The lungs of birds have long been known to move air in only one direction during both inspiration and expiration through most of the tubular gas-exchanging bronchi (parabronchi. Recently a similar pattern of airflow has been observed in American alligators, a sister taxon to birds. The pattern of flow appears to be due to the arrangement of the primary and secondary bronchi, which, via their branching angles, generate inspiratory and expiratory aerodynamic valves. Both the anatomical similarity of the avian and alligator lung and the similarity in the patterns of airflow raise the possibility that these features are plesiomorphic for Archosauria and therefore did not evolve in response to selection for flapping flight or an endothermic metabolism, as has been generally assumed. To further test the hypothesis that unidirectional airflow is ancestral for Archosauria, we measured airflow in the lungs of the Nile crocodile (Crocodylus niloticus. As in birds and alligators, air flows cranially to caudally in the cervical ventral bronchus, and caudally to cranially in the dorsobronchi in the lungs of Nile crocodiles. We also visualized the gross anatomy of the primary, secondary and tertiary pulmonary bronchi of C. niloticus using computed tomography (CT and microCT. The cervical ventral bronchus, cranial dorsobronchi and cranial medial bronchi display similar characteristics to their proposed homologues in the alligator, while there is considerable variation in the tertiary and caudal group bronchi. Our data indicate that the aspects of the crocodilian bronchial tree that maintain the aerodynamic valves and thus generate unidirectional airflow, are ancestral for Archosauria.

  10. Aging effects on airflow dynamics and lung function in human bronchioles.

    Science.gov (United States)

    Kim, JongWon; Heise, Rebecca L; Reynolds, Angela M; Pidaparti, Ramana M

    2017-01-01

    The mortality rate for patients requiring mechanical ventilation is about 35% and this rate increases to about 53% for the elderly. In general, with increasing age, the dynamic lung function and respiratory mechanics are compromised, and several experiments are being conducted to estimate these changes and understand the underlying mechanisms to better treat elderly patients. Human tracheobronchial (G1 ~ G9), bronchioles (G10 ~ G22) and alveolar sacs (G23) geometric models were developed based on reported anatomical dimensions for a 50 and an 80-year-old subject. The aged model was developed by altering the geometry and material properties of the model developed for the 50-year-old. Computational simulations using coupled fluid-solid analysis were performed for geometric models of bronchioles and alveolar sacs under mechanical ventilation to estimate the airflow and lung function characteristics. The airway mechanical characteristics decreased with aging, specifically a 38% pressure drop was observed for the 80-year-old as compared to the 50-year-old. The shear stress on airway walls increased with aging and the highest shear stress was observed in the 80-year-old during inhalation. A 50% increase in peak strain was observed for the 80-year-old as compared to the 50-year-old during exhalation. The simulation results indicate that there is a 41% increase in lung compliance and a 35%-50% change in airway mechanical characteristics for the 80-year-old in comparison to the 50-year-old. Overall, the airway mechanical characteristics as well as lung function are compromised due to aging. Our study demonstrates and quantifies the effects of aging on the airflow dynamics and lung capacity. These changes in the aging lung are important considerations for mechanical ventilation parameters in elderly patients. Realistic geometry and material properties need to be included in the computational models in future studies.

  11. Strongly coupled interaction between a ridge of fluid and an inviscid airflow

    KAUST Repository

    Paterson, C.

    2015-07-01

    © 2015 AIP Publishing LLC. The behaviour of a steady thin sessile or pendent ridge of fluid on an inclined planar substrate which is strongly coupled to the external pressure gradient arising from an inviscid airflow parallel to the substrate far from the ridge is described. When the substrate is nearly horizontal, a very wide ridge can be supported against gravity by capillary and/or external pressure forces; otherwise, only a narrower (but still wide) ridge can be supported. Classical thin-aerofoil theory is adapted to obtain the governing singular integro-differential equation for the profile of the ridge in each case. Attention is focused mainly on the case of a very wide sessile ridge. The effect of strengthening the airflow is to push a pinned ridge down near to its edges and to pull it up near to its middle. At a critical airflow strength, the upslope contact angle reaches the receding contact angle at which the upslope contact line de-pins, and continuing to increase the airflow strength beyond this critical value results in the de-pinned ridge becoming narrower, thicker, and closer to being symmetric in the limit of a strong airflow. The effect of tilting the substrate is to skew a pinned ridge in the downslope direction. Depending on the values of the advancing and receding contact angles, the ridge may first de-pin at either the upslope or the downslope contact line but, in general, eventually both contact lines de-pin. The special cases in which only one of the contact lines de-pins are also considered. It is also shown that the behaviour of a very wide pendent ridge is qualitatively similar to that of a very wide sessile ridge, while the important qualitative difference between the behaviour of a very wide ridge and a narrower ridge is that, in general, for the latter one or both of the contact lines may never de-pin.

  12. Childhood-onset asthma in smokers. association between CT measures of airway size, lung function, and chronic airflow obstruction.

    Science.gov (United States)

    Diaz, Alejandro A; Hardin, Megan E; Come, Carolyn E; San José Estépar, Raúl; Ross, James C; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K; Crapo, James D; Lynch, David A; Make, Barry; Barr, R Graham; Hersh, Craig P; Washko, George R

    2014-11-01

    Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764).

  13. Airflow Interaction Interface: Playful 3-D CAD and Gaming

    NARCIS (Netherlands)

    Wendrich, Robert E.

    2016-01-01

    This paper describes the vision and development of a tangible user interface (TUI) that allows ‘glassblowing-like’ interaction (IA) with a computer. The premise is that human fidelity in exerting pressure and airflow (i.e. breathing, blowing) could stimulate intuition, creative processing, and

  14. Fuel composition effect on cathode airflow control in fuel cell gas turbine hybrid systems

    Science.gov (United States)

    Zhou, Nana; Zaccaria, Valentina; Tucker, David

    2018-04-01

    Cathode airflow regulation is considered an effective means for thermal management in solid oxide fuel cell gas turbine (SOFC-GT) hybrid system. However, performance and controllability are observed to vary significantly with different fuel compositions. Because a complete system characterization with any possible fuel composition is not feasible, the need arises for robust controllers. The sufficiency of robust control is dictated by the effective change of operating state given the new composition used. It is possible that controller response could become unstable without a change in the gains from one state to the other. In this paper, cathode airflow transients are analyzed in a SOFC-GT system using syngas as fuel composition, comparing with previous work which used humidified hydrogen. Transfer functions are developed to map the relationship between the airflow bypass and several key variables. The impact of fuel composition on system control is quantified by evaluating the difference between gains and poles in transfer functions. Significant variations in the gains and the poles, more than 20% in most cases, are found in turbine rotational speed and cathode airflow. The results of this work provide a guideline for the development of future control strategies to face fuel composition changes.

  15. Effect of airflow on biodrying of gardening wastes in reactors.

    Science.gov (United States)

    Colomer-Mendoza, F J; Herrera-Prats, L; Robles-Martínez, F; Gallardo-Izquierdo, A; Piña-Guzmán, A B

    2013-05-01

    Biodrying consists of reducing moisture by using the heat from aerobic bio-degradation. The parameters that control the process are: aeration, temperature during the process, initial moisture of biowaste, and temperature and relative humidity of the input air. Lawn mowing and garden waste from the gardens of the University Jaume I, Castellón (Spain) were used as a substrate. Biodrying was performed in 10 reactors with known air volumes from 0.88 to 6.42 L/(min x kg dry weight). To promote aeration, 5 of the reactors had 15% of a bulking agent added. The experiment lasted 20 days. After the experiments it was found that the bulking agent led to greater weight loss. However, the increased airflow rate was not linearly proportional to the weight loss.

  16. Fine-scale flight strategies of gulls in urban airflows indicate risk and reward in city living.

    Science.gov (United States)

    Shepard, Emily L C; Williamson, Cara; Windsor, Shane P

    2016-09-26

    Birds modulate their flight paths in relation to regional and global airflows in order to reduce their travel costs. Birds should also respond to fine-scale airflows, although the incidence and value of this remains largely unknown. We resolved the three-dimensional trajectories of gulls flying along a built-up coastline, and used computational fluid dynamic models to examine how gulls reacted to airflows around buildings. Birds systematically altered their flight trajectories with wind conditions to exploit updraughts over features as small as a row of low-rise buildings. This provides the first evidence that human activities can change patterns of space-use in flying birds by altering the profitability of the airscape. At finer scales still, gulls varied their position to select a narrow range of updraught values, rather than exploiting the strongest updraughts available, and their precise positions were consistent with a strategy to increase their velocity control in gusty conditions. Ultimately, strategies such as these could help unmanned aerial vehicles negotiate complex airflows. Overall, airflows around fine-scale features have profound implications for flight control and energy use, and consideration of this could lead to a paradigm-shift in the way ecologists view the urban environment.This article is part of the themed issue 'Moving in a moving medium: new perspectives on flight'. © 2016 The Author(s).

  17. Room airflow studies using sonic anemometry.

    Science.gov (United States)

    Wasiolek, P T; Whicker, J J; Gong, H; Rodgers, J C

    1999-06-01

    To ensure prompt response by real-time air monitors to an accidental release of toxic aerosols in a workplace, safety professionals should understand airflow patterns. This understanding can be achieved with validated computational fluid dynamics (CFD) computer simulations, or with experimental techniques, such as measurements with smoke, neutrally buoyant markers, trace gases, or trace aerosol particles. As a supplementary technique to quantify airflows, the use of a state-of-the art, three-dimensional sonic anemometer was explored. This instrument allows for the precise measurements of the air-velocity vector components in the range of a few centimeters per second, which is common in many indoor work environments. Measurements of air velocities and directions at selected locations were made for the purpose of providing data for characterizing fundamental aspects of indoor air movement in two ventilated rooms and for comparison to CFD model predictions. One room was a mockup of a plutonium workroom, and the other was an actual functioning plutonium workroom. In the mockup room, air-velocity vector components were measured at 19 locations at three heights (60, 120 and 180 cm) with average velocities varying from 1.4 cm s-1 to 9.7 cm s-1. There were complex flow patterns observed with turbulence intensities from 39% up to 108%. In the plutonium workroom, measurements were made at the breathing-zone height, recording average velocities ranging from 9.9 cm s-1 to 35.5 cm s-1 with turbulence intensities from 33% to 108%.

  18. Measuring Outdoor Air Intake Rates into Existing Building

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William; Sullivan, Douglas; Cohen, Sebastian; Han, Hwataik

    2009-04-16

    Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10 percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15 percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100 percent, and were often greater than 25 percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

  19. Transient Dynamics Simulation of Airflow in a CT-Scanned Human Airway Tree: More or Fewer Terminal Bronchi?

    Directory of Open Access Journals (Sweden)

    Shouliang Qi

    2017-01-01

    Full Text Available Using computational fluid dynamics (CFD method, the feasibility of simulating transient airflow in a CT-based airway tree with more than 100 outlets for a whole respiratory period is studied, and the influence of truncations of terminal bronchi on CFD characteristics is investigated. After an airway model with 122 outlets is extracted from CT images, the transient airflow is simulated. Spatial and temporal variations of flow velocity, wall pressure, and wall shear stress are presented; the flow pattern and lobar distribution of air are gotten as well. All results are compared with those of a truncated model with 22 outlets. It is found that the flow pattern shows lobar heterogeneity that the near-wall air in the trachea is inhaled into the upper lobe while the center flow enters the other lobes, and the lobar distribution of air is significantly correlated with the outlet area ratio. The truncation decreases airflow to right and left upper lobes and increases the deviation of airflow distributions between inspiration and expiration. Simulating the transient airflow in an airway tree model with 122 bronchi using CFD is feasible. The model with more terminal bronchi decreases the difference between the lobar distributions at inspiration and at expiration.

  20. Chronic airflow obstruction after successful treatment of multidrug-resistant tuberculosis

    Directory of Open Access Journals (Sweden)

    Anthony L. Byrne

    2017-07-01

    Full Text Available Cross-sectional studies reveal an association between tuberculosis (TB and chronic airflow obstruction, but cannot adequately address confounding. We hypothesised that treated pulmonary TB is an independent risk factor for chronic airflow obstruction. The Pulmones Post TB cohort study enrolled participants from Lima, Peru, aged 10–70 years with a history of drug-susceptible (DS- or multidrug-resistant (MDR-TB who had completed treatment and were clinically cured. Unexposed participants without TB were randomly selected from the same districts. We assessed respiratory symptoms, relevant environmental exposures, and spirometric lung function pre- and post-bronchodilator. In total, 144 participants with DS-TB, 33 with MDR-TB and 161 unexposed participants were fully evaluated. Compared with unexposed participants, MDR-TB patients had lower lung volumes (adjusted mean difference in forced vital capacity −370 mL, 95% CI −644– −97 and post-bronchodilator airflow obstruction (adjusted OR 4.89, 95% CI 1.27–18.78. Participants who had recovered from DS-TB did not have lower lung volumes than unexposed participants, but were more likely to have a reduced forced expiratory volume in 1 s/forced vital capacity ratio <0.70 (adjusted OR 2.47, 95% CI 1.01–6.03. Individuals successfully treated for TB may experience long-lasting sequelae. Interventions facilitating earlier TB treatment and management of chronic respiratory disease should be explored.

  1. Visualization of nasal airflow patterns in a patient affected with atrophic rhinitis using particle image velocimetry

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, G J M [Hamner Institutes for Health Sciences, NC (United States); Mitchell, G [The Queens University of Belfast, Belfast (United Kingdom); Bailie, N [The Queens University of Belfast, Belfast (United Kingdom); Thornhill, D [The Queens University of Belfast, Belfast (United Kingdom); Watterson, J [The Queens University of Belfast, Belfast (United Kingdom); Kimbell, J S [Hamner Institutes for Health Sciences, NC (United States)

    2007-10-15

    The relationship between airflow patterns in the nasal cavity and nasal function is poorly understood. This paper reports an experimental study of the interplay between symptoms and airflow patterns in a patient affected with atrophic rhinitis. This pathology is characterized by mucosal dryness, fetor, progressive atrophy of anatomical structures, a spacious nasal cavity, and a paradoxical sensation of nasal congestion. A physical replica of the patient's nasal geometry was made and particle image velocimetry (PIV) was used to visualize and measure the flow field. The nasal replica was based on computed tomography (CT) scans of the patient and was built in three steps: three-dimensional reconstruction of the CT scans; rapid prototyping of a cast; and sacrificial use of the cast to form a model of the nasal passage in clear silicone. Flow patterns were measured by running a water-glycerol mixture through the replica and evaluating the displacement of particles dispersed in the liquid using PIV. The water-glycerol flow rate used corresponded to an air flow rate representative of a human breathing at rest. The trajectory of the flow observed in the left passage of the nose (more affected by atrophic rhinitis) differed markedly from what is considered normal, and was consistent with patterns of epithelial damage observed in cases of the condition. The data are also useful for validation of computational fluid dynamics predictions.

  2. Advanced airflow distribution methods for reducing exposure of indoor pollution

    DEFF Research Database (Denmark)

    Cao, Guangyu; Nielsen, Peter Vilhelm; Melikov, Arsen

    2017-01-01

    The adverse effect of various indoor pollutants on occupants’ health have been recognized. In public spaces flu viruses may spread from person to person by airflow generated by various traditional ventilation methods, like natural ventilation and mixing ventilation (MV Personalized ventilation (PV......) supplies clean air close to the occupant and directly into the breathing zone. Studies show that it improves the inhaled air quality and reduces the risk of airborne cross-infection in comparison with total volume (TV) ventilation. However, it is still challenging for PV and other advanced air distribution...... methods to reduce the exposure to gaseous and particulate pollutants under disturbed conditions and to ensure thermal comfort at the same time. The objective of this study is to analyse the performance of different advanced airflow distribution methods for protection of occupants from exposure to indoor...

  3. Advanced airflow distribution methods for reducing exposure of indoor pollution

    DEFF Research Database (Denmark)

    Cao, Guangyu; Nielsen, Peter Vilhelm; Melikov, Arsen Krikor

    methods to reduce the exposure to gaseous and particulate pollutants under disturbed conditions and to ensure thermal comfort at the same time. The objective of this study is to analyse the performance of different advanced airflow distribution methods for protection of occupants from exposure to indoor......The adverse effect of various indoor pollutants on occupants’ health have been recognized. In public spaces flu viruses may spread from person to person by airflow generated by various traditional ventilation methods, like natural ventilation and mixing ventilation (MV Personalized ventilation (PV......) supplies clean air close to the occupant and directly into the breathing zone. Studies show that it improves the inhaled air quality and reduces the risk of airborne cross-infection in comparison with total volume (TV) ventilation. However, it is still challenging for PV and other advanced air distribution...

  4. Effects of T-type Channel on Natural Convection Flows in Airflow-Path of Concrete Storage Cask

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Gyeong Uk; Kim, Hyoung Jin; Cho, Chun Hyung [KORAD, Daejeon (Korea, Republic of)

    2016-05-15

    The natural convection flows occurring in airflow-path are not simple due to complex flow-path configurations such as horizontal ducts, bent tube and annular flow-path. In addition, 16 T type channels acting as the shroud are attached vertically and 16 channel supporting the canister are attached horizontally on the inner surface of over-pack. The existence and nonexistence of T type channels have influences on the flow fields in airflow- path. The concrete storage cask has to satisfy the requirements to secure the thermal integrity under the normal, off-normal, and accident conditions. The present work is aiming at investigating the effects of T type channels on the flows in airflow-path under the normal conditions using the FLUENT 16.1 code. In order to focus on the flows in airflow-path, fuel regions in the canister are regarded as a single cylinder with heat sources and other components are fully modeled. This study investigated the flow fields in airflow-path of concrete storage cask, numerically. It was found that excepting for the fuel regions, maximum temperatures on other components were evaluated below allowable values. The location of maximum velocities depended on support channels, T type channels and flow area. The flows through air inlets developed along annular flow- path with forming the hot plumes. According to the existence and nonexistence of T type channel, the plume behavior showed the different flow patterns.

  5. Size reduction of ammonia scrubbers for pig and poultry houses: Use of conditional bypass vent at high air loading rates

    NARCIS (Netherlands)

    Melse, R.W.; Wagenberg, van A.V.; Mosquera, J.

    2006-01-01

    In The Netherlands, both acid and biological air scrubbers are used for removal of ammonia from exhaust air at pig and poultry houses. Current regulations require that scrubbers are dimensioned for treating the maximum airflow rate that may occur, so on average these systems are overdimensioned and

  6. Association of incidental emphysema with annual lung function decline and future development of airflow limitation

    Directory of Open Access Journals (Sweden)

    Koo HK

    2016-01-01

    Full Text Available Hyeon-Kyoung Koo,1 Kwang Nam Jin,2 Deog Kyeom Kim,3 Hee Soon Chung,3 Chang-Hoon Lee3,4 1Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, College of Medicine, Ilsan Paik Hospital, Inje University, Goyang-si, Gyeonggi-Do, 2Department of Radiology, Seoul Metropolitan Government – Seoul National University Boramae Medical Center, 3Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, 4Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea Objectives: Emphysema is one of the prognostic factors for rapid lung function decline in patients with COPD, but the impact of incidentally detected emphysema on population without spirometric abnormalities has not been evaluated. This study aimed to determine whether emphysema detected upon computed tomography (CT screening would accelerate the rate of lung function decline and influence the possibility of future development of airflow limitation in a population without spirometric abnormalities.Materials and methods: Subjects who participated in a routine screening for health checkup and follow-up pulmonary function tests for at least 3 years between 2004 and 2010 were retrospectively enrolled. The percentage of low-attenuation area below −950 Hounsfield units (%LAA−950 was calculated automatically. A calculated value of %LAA−950 that exceeded 10% was defined as emphysema. Adjusted annual lung function decline was analyzed using random-slope, random-intercept mixed linear regression models.Results: A total of 628 healthy subjects within the normal range of spriometric values were included. Multivariable analysis showed that the emphysema group exhibited a faster decline in forced vital capacity (−33.9 versus −18.8

  7. Room airflow studies using sonic anemometry

    International Nuclear Information System (INIS)

    Wasiolek, P.T.; Whicker, J.J.; Gong, H.; Rodgers, J.C.

    1999-01-01

    To ensure prompt response by real-time air monitors to an accidental release of toxic aerosols in a workplace, safety professionals should understand airflow patterns. This understanding can be achieved with validated computational fluid dynamics (CFD) computer simulations, or with experimental techniques, such as measurements with smoke, neutrally buoyant markers, trace gases, or trace aerosol particles. As a supplementary technique to quantify airflows, the use of a state-of-the-art, three-dimensional sonic anemometer was explored. This instrument allows for the precise measurements of the air-velocity vector components in the range of a few centimeters per second, which is common in many indoor work environments. Measurements of air velocities and directions at selected locations were made for the purpose of providing data for characterizing fundamental aspects of indoor air movement in two ventilated rooms and for comparison to CFD model predictions. One room was a mockup of a plutonium workroom, and the other was an actual functioning plutonium workroom. In the mockup room, air-velocity vector components were measured at 19 locations at three heights (60, 120 and 180 cm) with average velocities varying from 1.4 cm s -1 to 9.7 cm s -1 . There were complex flow patterns observed with turbulence intensities from 39% up to 108%. In the plutonium workroom, measurements were made at the breathing-zone height, recording average velocities ranging from 9.9 cm s -1 to 35.5 cm s -1 with turbulence intensities from 33% to 108%. (au)

  8. Room airflow studies using sonic anemometry

    Energy Technology Data Exchange (ETDEWEB)

    Wasiolek, P.T.; Whicker, J.J.; Gong, H.; Rodgers, J.C. [Los Alamos National Lab., Health Physics Measurements Group, Los Alamos, NM (United States)

    1999-10-01

    To ensure prompt response by real-time air monitors to an accidental release of toxic aerosols in a workplace, safety professionals should understand airflow patterns. This understanding can be achieved with validated computational fluid dynamics (CFD) computer simulations, or with experimental techniques, such as measurements with smoke, neutrally buoyant markers, trace gases, or trace aerosol particles. As a supplementary technique to quantify airflows, the use of a state-of-the-art, three-dimensional sonic anemometer was explored. This instrument allows for the precise measurements of the air-velocity vector components in the range of a few centimeters per second, which is common in many indoor work environments. Measurements of air velocities and directions at selected locations were made for the purpose of providing data for characterizing fundamental aspects of indoor air movement in two ventilated rooms and for comparison to CFD model predictions. One room was a mockup of a plutonium workroom, and the other was an actual functioning plutonium workroom. In the mockup room, air-velocity vector components were measured at 19 locations at three heights (60, 120 and 180 cm) with average velocities varying from 1.4 cm s{sup -1} to 9.7 cm s{sup -1}. There were complex flow patterns observed with turbulence intensities from 39% up to 108%. In the plutonium workroom, measurements were made at the breathing-zone height, recording average velocities ranging from 9.9 cm s{sup -1} to 35.5 cm s{sup -1} with turbulence intensities from 33% to 108%. (au) 17 refs.

  9. Inflammatory Biomarkers Predict Airflow Obstruction After Exposure to World Trade Center Dust

    Science.gov (United States)

    Nolan, Anna; Naveed, Bushra; Comfort, Ashley L.; Ferrier, Natalia; Hall, Charles B.; Kwon, Sophia; Kasturiarachchi, Kusali J.; Cohen, Hillel W.; Zeig-Owens, Rachel; Glaser, Michelle S.; Webber, Mayris P.; Aldrich, Thomas K.; Rom, William N.; Kelly, Kerry; Prezant, David J.

    2012-01-01

    Background: The World Trade Center (WTC) collapse on September 11, 2001, produced airflow obstruction in a majority of firefighters receiving subspecialty pulmonary evaluation (SPE) within 6.5 years post-September 11, 2001. Methods: In a cohort of 801 never smokers with normal pre-September 11, 2001, FEV1, we correlated inflammatory biomarkers and CBC counts at monitoring entry within 6 months of September 11, 2001, with a median FEV1 at SPE (34 months; interquartile range, 25-57). Cases of airflow obstruction had FEV1 less than the lower limit of normal (LLN) (100 of 801; 70 of 100 had serum), whereas control subjects had FEV1 greater than or equal to LLN (153 of 801; 124 of 153 had serum). Results: From monitoring entry to SPE years later, FEV1 declined 12% in cases and increased 3% in control subjects. Case subjects had elevated serum macrophage derived chemokine (MDC), granulocyte-macrophage colony-stimulating factor (GM-CSF), granulocyte colony-stimulating factor, and interferon inducible protein-10 levels. Elevated GM-CSF and MDC increased the risk for subsequent FEV1 less than LLN by 2.5-fold (95% CI, 1.2-5.3) and 3.0-fold (95% CI, 1.4-6.1) in a logistic model adjusted for exposure, BMI, age on September 11, 2001, and polymorphonuclear neutrophils. The model had sensitivity of 38% (95% CI, 27-51) and specificity of 88% (95% CI, 80-93). Conclusions: Inflammatory biomarkers can be risk factors for airflow obstruction following dust and smoke exposure. Elevated serum GM-CSF and MDC levels soon after WTC exposure were associated with increased risk of airflow obstruction in subsequent years. Biomarkers of inflammation may help identify pathways producing obstruction after irritant exposure. PMID:21998260

  10. Estimation of the site of wheezes in pulmonary emphysema: airflow simulation study by the use of A 4D lung model.

    Science.gov (United States)

    Kitaoka, Hiroko; Cok, Salim

    2013-01-01

    Adventitious lung sounds in pulmonary emphysema, wheezes, are continuous musical sounds during expiration with 400 Hz or more. The textbook tells that expiratory airflow limitation in emphysema occurs at the peripheral airways and that wheezes are generated there. We have recently proposed a novel hypothesis based on image analysis and theoretical consideration that expiratory airflow limitation in emphysema occurs at the intra-mediastinal airway (trachea, main bronchi, and right lobar bronchi) due to compression by overinflated lungs. We performed expiratory airflow simulation by the use of a 4D finite element lung model, and found periodical vortex release with 300-900 Hz at the end of protrusion of the the tracheal posterior wall. Relationship between the peak frequency of pressure fluctuation and airflow velocity was in agreement with Strahal's law either in normal or emphysematous condition. Contrarily, airflow simulation in a small bronchus (1.5 mm in diameter) indicated no apparent periodic vortex release.

  11. Computational fluid dynamics (CFD) investigation of impacts of an obstruction on airflow in underground mines.

    Science.gov (United States)

    Zhou, L; Goodman, G; Martikainen, A

    2013-01-01

    Continuous airflow monitoring can improve the safety of the underground work force by ensuring the uninterrupted and controlled distribution of mine ventilation to all working areas. Air velocity measurements vary significantly and can change rapidly depending on the exact measurement location and, in particular, due to the presence of obstructions in the air stream. Air velocity must be measured at locations away from obstructions to avoid the vortices and eddies that can produce inaccurate readings. Further, an uninterrupted measurement path cannot always be guaranteed when using continuous airflow monitors due to the presence of nearby equipment, personnel, roof falls and rib rolls. Effective use of these devices requires selection of a minimum distance from an obstacle, such that an air velocity measurement can be made but not affected by the presence of that obstacle. This paper investigates the impacts of an obstruction on the behavior of downstream airflow using a numerical CFD model calibrated with experimental test results from underground testing. Factors including entry size, obstruction size and the inlet or incident velocity are examined for their effects on the distributions of airflow around an obstruction. A relationship is developed between the minimum measurement distance and the hydraulic diameters of the entry and the obstruction. A final analysis considers the impacts of continuous monitor location on the accuracy of velocity measurements and on the application of minimum measurement distance guidelines.

  12. Mechanics of airflow in the human nasal airways.

    Science.gov (United States)

    Doorly, D J; Taylor, D J; Schroter, R C

    2008-11-30

    The mechanics of airflow in the human nasal airways is reviewed, drawing on the findings of experimental and computational model studies. Modelling inevitably requires simplifications and assumptions, particularly given the complexity of the nasal airways. The processes entailed in modelling the nasal airways (from defining the model, to its production and, finally, validating the results) is critically examined, both for physical models and for computational simulations. Uncertainty still surrounds the appropriateness of the various assumptions made in modelling, particularly with regard to the nature of flow. New results are presented in which high-speed particle image velocimetry (PIV) and direct numerical simulation are applied to investigate the development of flow instability in the nasal cavity. These illustrate some of the improved capabilities afforded by technological developments for future model studies. The need for further improvements in characterising airway geometry and flow together with promising new methods are briefly discussed.

  13. CFD modeling of airflow for indoor comfort in the tropics

    International Nuclear Information System (INIS)

    Aynsley, R.; Su, B.

    2006-01-01

    In humid tropical environments air movement is a common means to achieving indoor thermal comfort. In many locations closer to the equator, breezes are weaker and less reliable. Whatever the source of air movement it is important to quantity its potential in terms of the percentage of time the air movement will be available and the likely speed of the air movement in occupied zone of a building. It is also important to establish appropriate thermal comfort criteria with respect to air temperature, humidity and air movement. There are a number of techniques for modeling air movement inside naturally ventilated buildings. Boundary layer wind tunnels provide an opportunity to both measure and visually observe such airflow through model building. It is important to model adjacent buildings and any significant landscaping features that will influence outdoor airflow patterns. Such studies are relatively expensive. The recent availability of computational fluid dynamics (CFD) software for personal computers offers an alternative method for modeling air movement inside naturally ventilated buildings. Very expensive versions of this software have been available for large computers and work stations for many years but they have only recently become available for smaller computers. There are some features of such software that should be compared before purchasing a copy or a license. This paper discusses such features in detail. It is important in the case of natural ventilation that adjacent buildings and any significant landscaping features that will influence outdoor airflow patterns are included in the modeling. This paper also stresses the importance of calibrating the CFD software output against some physical measurements or wind tunnel modeling to ensure that the CFD results are realistic

  14. Three distinct surgical clothing systems in a turbulent mixing operating room equipped with mobile ultraclean laminar airflow screen

    DEFF Research Database (Denmark)

    Sadrizadeh, Sasan; Holmberg, Sture; Nielsen, Peter Vilhelm

    2016-01-01

    on the operating and instrument tables with and without the additional mobile airflow screen. Three different source strengths (the mean bacteria-carrying particle value emitted from one person per second) due to staff clothing variety were considered. Model validation was performed through result comparisons...... a clothing system with high protective capacity reduced particle concentration....

  15. Numerical simulation of airway dimension effects on airflow patterns and odorant deposition patterns in the rat nasal cavity.

    Directory of Open Access Journals (Sweden)

    Zehong Wei

    Full Text Available The sense of smell is largely dependent on the airflow and odorant transport in the nasal cavity, which in turn depends on the anatomical structure of the nose. In order to evaluate the effect of airway dimension on rat nasal airflow patterns and odorant deposition patterns, we constructed two 3-dimensional, anatomically accurate models of the left nasal cavity of a Sprague-Dawley rat: one was based on high-resolution MRI images with relatively narrow airways and the other was based on artificially-widening airways of the MRI images by referencing the section images with relatively wide airways. Airflow and odorant transport, in the two models, were determined using the method of computational fluid dynamics with finite volume method. The results demonstrated that an increase of 34 µm in nasal airway dimension significantly decreased the average velocity in the whole nasal cavity by about 10% and in the olfactory region by about 12% and increased the volumetric flow into the olfactory region by about 3%. Odorant deposition was affected to a larger extent, especially in the olfactory region, where the maximum odorant deposition difference reached one order of magnitude. The results suggest that a more accurate nasal cavity model is necessary in order to more precisely study the olfactory function of the nose when using the rat.

  16. Simulation of whole building coupled hygrothermal-airflow transfer in different climates

    International Nuclear Information System (INIS)

    Qin Menghao; Walton, George; Belarbi, Rafik; Allard, Francis

    2011-01-01

    The coupled heat, air and moisture transfer between building envelopes and indoor air is complicated, and has a significant influence on the indoor environment and the energy performance of buildings. In the paper, a model for predicting coupled multi-zone hygrothermal-airflow transfer is presented. Both heat and moisture transfer in the building envelope and multi-zone indoor airflow are simultaneously considered; their interactions are modeled. The coupled system model is implemented into Matlab-Simulink, and is validated by using a series of testing tools and experiments. The new program is applied to investigate the moisture transfer effect on indoor air humidity and building energy consumption in different climates (hot-humid, temperate and hot-dry climates). The results show that not accounting for hygrothermal effects in modeling will result in overestimation of energy costs for hot and humid climate situations and possible over sizing of plant leading to inefficient operation.

  17. Effects of single-sided inferior turbinectomy on nasal function and airflow characteristics.

    Science.gov (United States)

    Na, Yang; Chung, Kang Soo; Chung, Seung-Kyu; Kim, Sung Kyun

    2012-03-15

    Knowledge of airflow characteristics in the nasal cavity is essential to understanding the physiologic and pathologic aspects of nasal breathing. Airflows inside post-surgery models were investigated both experimentally and numerically to simulate the inferior turbinectomy. The left cavities of all three models are normal and right cavity is modified by (1) excision of the head of the inferior turbinate, (2) resection of the lower fifth of the inferior turbinate, and (3) resection of almost the entire inferior turbinate. Thin-slice CT (computed tomography) data (0.6mm deep) and meticulous refinement of the model surface by over a decade-long collaboration between engineers and an experienced ENT doctor resulted in the creation of sophisticated nasal cavity models. After numerical experiments and validation by comparison with the PIV results, the CFD code using the Reynolds stress turbulent model and variable temperature boundary condition on the mucosal wall was chosen as the proper numerical framework. Both global quantities (pressure drop, flow rate ratio, total wall heat transfer) and local changes (velocity, temperature, humidity, pressure gradient, and wall shear stress) were numerically investigated. The turbinectomy obviously altered the main stream direction. The flow rate in the upper airway near the olfactory slit decreased in models (1) and (3). This may weaken the olfactory function of the nose. Fluid and thermal properties that are believed to be related with physiology and prognosis are dependent on turbinate resection volume, position, and manner. Widening of the inferior airway does not always result in decreased flow resistance or wall heat transfer. The gains and losses of inferior turbinectomy were considered by analysis of the post-surgery model results. Nasal resistance was increased in model (1) due to sudden airway expansion. Nasal resistance increased and the wall heat transfer decreased in model (3) due to sudden airway expansion and

  18. Airflow and Contaminant Distribution in Hospital Wards with a Displacement Ventililation System

    DEFF Research Database (Denmark)

    Qian, H.; Nielsen, Peter Vilhelm; Li, Y.

    2004-01-01

    Airflow and Contaminant Distribution in Hospital Wards with a Displacement Ventilalation System. The 2nd International Conference on Build Environment and Public Health, BEPH 2004, Shenzhen , China . ABSTRACT Displacement ventilation has not been considered to be an applicable system for hospital...... to accurately predict three-dimensional distribution of air velocity, temperature, and contaminant concentration in the ward. Indoor airflow in a displacement ventilation system involves a combination of different flow streams such as the gravity currents and thermal plumes. It is important to choose...... ventilation system in hospital wards. It is for this purpose that we study the performance of displacement ventilation in hospital wards as one of the steps to optimize the ventilation design. When the prospect of applying displacement ventilation system in a hospital ward is examined, it should be necessary...

  19. Numerical investigation of diffuser solidity effect on turbulent airflow and performance of the turbocharger compressor

    Directory of Open Access Journals (Sweden)

    Chehhat A.

    2016-12-01

    Full Text Available Low solidity diffuser in centrifugal compressors can achieve both high efficiency and wide operating ranges which is of great importance for turbocharger compressor. Low solidity is achieved by using a low chord to pitch ratio. In this work, a CFD simulation is carried out to examine the effect of solidity on airflow field of a turbocharger centrifugal compressor which consists of a simple-splitter impeller and a vaned diffuser. By changing the number of diffuser vanes while keeping the number of impeller blades constant, the solidity value of the diffuser is varied. The characteristics of the compressor are evaluated for 6, 8, 10 and 12 stator vanes which correspond to solidity of: 0.78, 1.04, 1.29 and 1.55, respectively. The spatial distribution of the pressure, velocity and turbulent kinetic energy show that the diffuser solidity has significant effect on flow field and compressor performance map. The compressor with a 6 vanes diffuser has higher efficiency and operates at a wider range of flow rate relative to that obtained with larger vans number. However a non-uniform flow at the compressor exit was observed with relatively high turbulent kinetic energy.

  20. Numerical simulations of island effects on airflow and weather during the summer over the island of Oahu

    Science.gov (United States)

    Hiep Van Nguyen; Yie-Leng Chen; Francis Fujioka

    2010-01-01

    The high-resolution (1.5 km) nonhydrostatic fifth-generation Pennsylvania StateUniversity–National Center for Atmospheric Research (PSU–NCAR) Mesoscale Model (MM5) and an advanced land surface model (LSM) are used to study the island-induced airflow and weather for the island of Oahu, Hawaii, under summer trade wind conditions. Despite Oahu’s relatively small...

  1. Testing measurements of airflow velocity in road tunnels

    Directory of Open Access Journals (Sweden)

    Danišovič Peter

    2017-01-01

    Full Text Available Within the project entitled “Models of formation and spread of fire to increase safety of road tunnels”, it was necessary to devise a method how to record airflow velocity during the fire in situ tests in road tunnels. Project is in first year of its solution so one testing measurement was performed to check the functionality of anemometers selected for this project and the first in situ measurement was also performed just a few days ago.

  2. Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models.

    Science.gov (United States)

    Corley, R A; Minard, K R; Kabilan, S; Einstein, D R; Kuprat, A P; Harkema, J R; Kimbell, J S; Gargas, M L; Kinzell, John H

    2009-05-01

    The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation. These airflow calculations, along with nasal airway geometry determinations, are critical parameters for hybrid CFD/physiologically based pharmacokinetic models that describe the nasal dosimetry of water-soluble or reactive gases and vapors in rabbits. CFD simulations were based upon three-dimensional computational meshes derived from magnetic resonance images of three adult female New Zealand White (NZW) rabbits. In the anterior portion of the nose, the maxillary turbinates of rabbits are considerably more complex than comparable regions in rats, mice, monkeys, or humans. This leads to a greater surface area to volume ratio in this region and thus the potential for increased extraction of water soluble or reactive gases and vapors in the anterior portion of the nose compared to many other species. Although there was considerable interanimal variability in the fine structures of the nasal turbinates and airflows in the anterior portions of the nose, there was remarkable consistency between rabbits in the percentage of total inspired airflows that reached the ethmoid turbinate region (approximately 50%) that is presumably lined with olfactory epithelium. These latter results (airflows reaching the ethmoid turbinate region) were higher than previous published estimates for the male F344 rat (19%) and human (7%). These differences in regional airflows can have significant implications in interspecies extrapolations of nasal dosimetry.

  3. Experimental investigation of nasal airflow.

    Science.gov (United States)

    Doorly, D; Taylor, D J; Franke, P; Schroter, R C

    2008-05-01

    The airway geometry of the nasal cavity is manifestly complex, and the manner in which it controls the airflow to accomplish its various physiological functions is not fully understood. Since the complex morphology and inaccessibility of the nasal passageways precludes detailed in-vivo measurements, either computational simulation or in-vitro experiments are needed to determine how anatomical form and function are related. The fabrication of a replica model of the nasal cavity, of a high optical clarity and derived from in-vivo scan data is described here, together with characteristics of the flow field investigated using particle image velocimetry (PIV) and flow visualization. Flow visualization is shown to be a capable and convenient technique for identifying key phenomena. Specifically the emergence of the jet from the internal nasal valve into the main cavity, how it impacts on the middle turbinate, and the large enhancement of dispersion that accompanies the initial appearance of flow instability are revealed as particularly significant features. The findings from the visualization experiments are complemented by PIV imaging, which provides quantitative detail on the variations in velocity in different regions of the nasal cavity. These results demonstrate the effectiveness of the cavity geometry in partitioning the flow into high shear zones, which facilitate rapid heat transfer and humidification from the nasal mucosa, and slower zones affording greater residence times to facilitate olfactory sensing. The experimental results not only provide a basis for comparison with other computational modelling but also demonstrate an alternative and flexible means to investigate complex flows, relevant to studies in different parts of the respiratory or cardiovascular systems.

  4. Numerical Simulations of Airflow and Droplet Dispersion in a Horizontal Ammonia Scrubber

    DEFF Research Database (Denmark)

    Liu, Li; Nielsen, Peter Vilhelm; Heiselberg, Per Kvols

    2015-01-01

    Ammonia released in pig production industries can lead to eutrophication of surface waters, soil acidification, fertilization of vegetation and changes in ecosystems, etc. Air scrubbers with spray of aerosolized sulphur solution were used to remove the ammonia mixed in the airflow ventilated out...... plate or a flow straightener were tested. Impact of nozzle velocity and droplet residue size were analysed. It is found that additional input on the pump pressure to increase the injection velocity may not cause any more benefit in our cases, and the ammonia removal efficiency of the horizontal scrubber...... from a piggery. In this study, numerical method were used to investigate airflow pattern, droplet dispersion, ammonia absorption at droplet surface and overall removal efficiency in an air cleaner. Droplet trajectories and elapsed time in air were adopted to characterize the absorption efficiency...

  5. Occupational exposures to solvents and metals are associated with fixed airflow obstruction

    NARCIS (Netherlands)

    Alif, Sheikh M; Dharmage, Shyamali C; Benke, Geza; Dennekamp, Martine; Burgess, John A; Perret, Jennifer L; Lodge, Caroline J; Morrison, Stephen; Johns, David P; Giles, Graham G.; Gurrin, Lyle C; Thomas, Paul S; Hopper, John L; Wood-Baker, Richard; Thompson, Bruce R; Feather, Iain H; Vermeulen, Roel; Kromhout, Hans; Walters, E Haydn; Abramson, Michael J; Matheson, Melanie C

    2017-01-01

    Objectives This study investigated the associations between occupational exposures to solvents and metals and fixed airflow obstruction (AO) using post-bronchodilator spirometry. Methods We included 1335 participants from the 2002-2008 follow-up of the Tasmanian Longitudinal Health Study.

  6. Changes in Peak Airflow Measurement During Maximal Cough After Vocal Fold Augmentation in Patients With Glottic Insufficiency.

    Science.gov (United States)

    Dion, Gregory R; Achlatis, Efstratios; Teng, Stephanie; Fang, Yixin; Persky, Michael; Branski, Ryan C; Amin, Milan R

    2017-11-01

    Compromised cough effectiveness is correlated with dysphagia and aspiration. Glottic insufficiency likely yields decreased cough strength and effectiveness. Although vocal fold augmentation favorably affects voice and likely improves cough strength, few data exist to support this hypothesis. To assess whether vocal fold augmentation improves peak airflow measurements during maximal-effort cough following augmentation. This case series study was conducted in a tertiary, academic laryngology clinic. Participants included 14 consecutive individuals with glottic insufficiency due to vocal fold paralysis, which was diagnosed via videostrobolaryngoscopy as a component of routine clinical examination. All participants who chose to proceed with augmentation were considered for the study whether office-based or operative augmentation was planned. Postaugmentation data were collected only at the first follow-up visit, which was targeted for 14 days after augmentation but varied on the basis of participant availability. Data were collected from June 5, 2014, to October 1, 2015. Data analysis took place between October 2, 2015, and March 3, 2017. Peak airflow during maximal volitional cough was quantified before and after vocal fold augmentation. Participants performed maximal coughs, and peak expiratory flow during the maximal cough was captured according to American Thoracic Society guidelines. Among the 14 participants (7 men and 7 women), the mean (SD) age was 62 (18) years. Three types of injectable material were used for vocal fold augmentation: carboxymethylcellulose in 5 patients, hyaluronic acid in 5, and calcium hydroxylapatite in 4. Following augmentation, cough strength increased in 11 participants and decreased cough strength was observed in 3. Peak airflow measurements during maximal cough varied from a decrease of 40 L/min to an increase of 150 L/min following augmentation. When preaugmentation and postaugmentation peak airflow measurements were compared, the

  7. EFFECTS OF TEMPERATURE AND AIRFLOW ON VOLUME DEVELOPMENT DURING BAKING AND ITS INFLUENCE ON QUALITY OF CAKE

    OpenAIRE

    NURUL ATIQAH SANI; FARAH SALEENA TAIP; SITI MAZLINA MUSTAPA KAMAL; NORASHIKIN AB. AZIZ

    2014-01-01

    Volume and texture of cake are among the important parameters in measuring the quality of cake. The processing conditions play important roles in producing cakes of good quality. Recent studies focused more on the formulation and the manipulation of baking temperature, humidity and time instead of airflow condition. The objective of this study was to evaluate the effects of baking temperature and airflow on the volume development of cake and final cake quality such as volume development, firm...

  8. EVALUATION OF A KILN INCORPORATING AN OSCILLATING PLATE AIRFLOW SYSTEM

    OpenAIRE

    Campean,Mihaela; Marinescu,Ion; Ispas,Mihai

    2003-01-01

    Boards of spruce (Picea abies) were dried in a pilot kiln with an oscillating plate that provides -"alternating air movement in the stack". The paper outlines the airflow concept and provides results for drying time and quality.It is suggested that the system has certain advantages which make it suitable as an alternative to conventional drying, especially for small-sized enterprises

  9. Numerical study of the air-flow in an oscillating water column wave energy converter

    Energy Technology Data Exchange (ETDEWEB)

    Paixao Conde, J.M. [Department of Mechanical and Industrial Engineering, Faculty of Sciences and Technology, New University of Lisbon, Monte de Caparica, 2829-516 Caparica (Portugal); IDMEC, Instituto Superior Tecnico, Technical University of Lisbon, 1049-001 Lisboa (Portugal); Gato, L.M.C. [IDMEC, Instituto Superior Tecnico, Technical University of Lisbon, 1049-001 Lisboa (Portugal)

    2008-12-15

    The paper presents a numerical study of the air-flow in a typical pneumatic chamber geometry of an oscillating water column (OWC)-type wave energy converter (WEC), equipped with two vertical-axis air turbines, asymmetrically placed on the top of the chamber. Outwards and inwards, steady and periodic, air-flow calculations were performed to investigate the flow distribution at the turbines' inlet sections, as well as the properties of the air-jet impinging on the water free-surface. The original design of the OWC chamber is likely to be harmful for the operation of the turbines due to the possible air-jet-produced water-spray at the water free-surface subsequently ingested by the turbine. A geometry modification of the air chamber, using a horizontal baffle-plate to deflect the air from the turbines, is proposed and proved to be very effective in reducing the risk of water-spray production from the inwards flow. The flow distribution at the turbines' inlet sections for the outwards flow was found to be fairly uniform for the geometries considered, providing good inlet flow conditions for the turbines. Steady flow was found to be an acceptable model to study the air-flow inside the pneumatic chamber of an OWC-WEC. (author)

  10. Hybridized electromagnetic-triboelectric nanogenerator for scavenging air-flow energy to sustainably power temperature sensors.

    Science.gov (United States)

    Wang, Xue; Wang, Shuhua; Yang, Ya; Wang, Zhong Lin

    2015-04-28

    We report a hybridized nanogenerator with dimensions of 6.7 cm × 4.5 cm × 2 cm and a weight of 42.3 g that consists of two triboelectric nanogenerators (TENGs) and two electromagnetic generators (EMGs) for scavenging air-flow energy. Under an air-flow speed of about 18 m/s, the hybridized nanogenerator can deliver largest output powers of 3.5 mW for one TENG (in correspondence of power per unit mass/volume: 8.8 mW/g and 14.6 kW/m(3)) at a loading resistance of 3 MΩ and 1.8 mW for one EMG (in correspondence of power per unit mass/volume: 0.3 mW/g and 0.4 kW/m(3)) at a loading resistance of 2 kΩ, respectively. The hybridized nanogenerator can be utilized to charge a capacitor of 3300 μF to sustainably power four temperature sensors for realizing self-powered temperature sensor networks. Moreover, a wireless temperature sensor driven by a hybridized nanogenerator charged Li-ion battery can work well to send the temperature data to a receiver/computer at a distance of 1.5 m. This work takes a significant step toward air-flow energy harvesting and its potential applications in self-powered wireless sensor networks.

  11. Human perception of air movement. Impact of frequency and airflow direction on draught sensation

    Energy Technology Data Exchange (ETDEWEB)

    Genhong Zhou

    1999-08-01

    Draught is defined as an unwanted local cooling of the human body caused by air movement. Air velocity and temperature are the main characteristics of air movement in rooms. Characteristics of instantaneous air velocity and temperature records previously measured in ventilated indoor spaces were analyzed. Air velocity and temperature fluctuated randomly. The amplitude and frequency of the fluctuations changed over time. Air movements around the human body were measured with a three-dimensional laser Doppler amemometer. A new parameter, equivalent frequency, was defined as an integral single parameter for describing the frequency characteristics of air velocity. The equivalent frequency of a randomly fluctuating velocity is defined as the frequency of sinusoidal velocity fluctuations with the same ratio of the standard deviation of acceleration to the standard deviation of air velocity as in the random velocity fluctuations. The equivalent frequencies of numerous instantaneous air-velocity records measured in ventilated space were analysed. The equivalent frequency of an airflow in an indoor space was found to be 0.1 to 2 Hz. The equivalent frequencies of most of the airflows were between 0.2 and 0.6 Hz. The relation between equivalent frequency and mean air velocity and standard deviation was established. Experiments were performed to identify the impact of the equivalent frequency on the human perception of draught. Forty subjects (20 women and 20 men) were subjected to airflows from behind with mean air velocities of 0.1, 0.2 and 0.3 m/s, with equivalent frequencies from 0 to 1 Hz at an air temperature of 20 deg. C. In this human-subject experimental study the frequency was found to have a significant impact on draught sensation. Subjects were more sensitive to airflow at an equivalent frequency between 0.2 and 0.6 Hz. A mathematical model for the simulation of draught was established and a computer program was developed for simulating the draught. The program

  12. WIND TUNNEL RESEARCH ON THE INFLUENCE OF ACTIVE AIRFLOW ON THE LIFT FORCE GENERATED BY THE AIRFOIL

    Directory of Open Access Journals (Sweden)

    Paweł Magryta

    2013-09-01

    Full Text Available The paper discusses the results of wind tunnel tests of airfoils with additional active airflow applied to their upper surfaces. These studies were carried out for a range of velocities up to 28 m/s in an open wind tunnel. Several types of airfoils selected for the examination feature different geometries and are widely applied in today’s aviation industry. The changes in the lift and drag force generated by these airfoils were recorded during the study. The test bench for the tests was equipped with a compressor and a vacuum pump to enable airflow through some holes on the airfoil upper surface. A rapid prototyping method and a 3D printer based on a powder printing technique were applied to print the airfoils. All of their surfaces were subject to surface grinding to smooth their external surfaces. The wind tunnel tests with and without active airflow applied to airfoils are summarised in the paper.

  13. Study on airflow characteristics of rear wing of F1 car

    Science.gov (United States)

    Azmi, A. R. S.; Sapit, A.; Mohammed, A. N.; Razali, M. A.; Sadikin, A.; Nordin, N.

    2017-09-01

    The paper aims to investigate CFD simulation is carried out to investigate the airflow along the rear wing of F1 car with Reynold number of 3 × 106 and velocity, u = 43.82204 m/s. The analysis was done using 2-D model consists of main plane and flap wing, combined together to form rear wing module. Both of the aerofoil is placed inside a box of 350mm long and 220mm height according to regulation set up by FIA. The parameters for this study is the thickness and the chord length of the flap wing aerofoil. The simulations were performed by using FLUENT solver and k-kl-omega model. The wind speed is set up to 43 m/s that is the average speed of F1 car when cornering. This study uses NACA 2408, 2412, and 2415 for the flap wing and BE50 for the main plane. Each cases being simulated with a gap between the aerofoil of 10mm and 50mm when the DRS is activated. Grid independence test and validation was conduct to make sure the result obtained is acceptable. The goal of this study is to investigate aerodynamic behavior of airflow around the rear wing as well as to see how the thickness and the chord length of flap wing influence the airflow at the rear wing. The results show that increasing in thickness of the flap wing aerofoil will decreases the downforce. The results also show that although the short flap wing generate lower downforce than the big flap wing, but the drag force can be significantly reduced as the short flap wing has more change in angle of attack when it is activated. Therefore, the type of aerofoil for the rear wing should be decided according to the circuit track so that it can be fully optimized.

  14. Nasal lavage cellularity, grain dust, and airflow obstruction.

    Science.gov (United States)

    Blaski, C A; Watt, J L; Quinn, T J; Thorne, P S; Schwartz, D A

    1996-04-01

    To evaluate the clinical utility of nasal lavage (NL), we performed post-work shift NL on 172 grain workers and 78 postal worker control subjects. The grain worker group included a higher percentage of current smokers (25.7% vs 16.7%) and a lower percentage of former smokers (21.15% vs 35.9%) compared with the postal workers. The control subjects included more female workers and were slightly older than the grain workers. Compared with the postal workers, the grain workers were exposed to significantly greater concentrations of total dust (0.1 +/- 0.0 vs 6.8 +/- 1.4 mg/m3; mean +/- SEM) and total endotoxin (4.3 +/- 0.8 vs 2,372.4 +/- 653.8 endotoxin units/m3). NL from gain workers showed a higher concentration of total cells (55,000 +/- 14,000 vs 25,000 +/- 5,000 cells per milliliter; p=0.03), a higher concentration of squamous epithelial cells (17,029.0 +/- 4,177 .0 vs 7,103.7 +/- 1,479.8 cells per milliliter; p=0.03), and a higher concentration of neutrophils (40,058.0 +/- 12,803.2 vs 17,891.0 +/- 3,822.3 cells per milliliter; p=0.10) compared with postal workers. Importantly, these differences in NL cellularity between grain workers and postal workers were observed within the three strata of smokers. To further assess the importance of total cells, squamous epithelial cells, and neutrophils in the NL fluid of grain workers, we investigated the relationship between these cell concentrations and (1) measures of dust and endotoxin exposure during the work shift. (2) spirometric measures of airflow obtained immediately before the NL, and (3) work-related respiratory symptoms. The concentration of total cells, the concentration of squamous epithelial cells, or the concentration of neutrophils in the NL was not associated with ambient levels of dust or endotoxin, with baseline or cross-shift changes in lung function, or with work-related respiratory symptoms. These findings suggest that increased NL cellularity may be seen in workers exposed to high dust levels

  15. Modeling airflow and particle transport/deposition in pulmonary airways.

    Science.gov (United States)

    Kleinstreuer, Clement; Zhang, Zhe; Li, Zheng

    2008-11-30

    A review of research papers is presented, pertinent to computer modeling of airflow as well as nano- and micron-size particle deposition in pulmonary airway replicas. The key modeling steps are outlined, including construction of suitable airway geometries, mathematical description of the air-particle transport phenomena and computer simulation of micron and nanoparticle depositions. Specifically, diffusion-dominated nanomaterial deposits on airway surfaces much more uniformly than micron particles of the same material. This may imply different toxicity effects. Due to impaction and secondary flows, micron particles tend to accumulate around the carinal ridges and to form "hot spots", i.e., locally high concentrations which may lead to tumor developments. Inhaled particles in the size range of 20nm< or =dp< or =3microm may readily reach the deeper lung region. Concerning inhaled therapeutic particles, optimal parameters for mechanical drug-aerosol targeting of predetermined lung areas can be computed, given representative pulmonary airways.

  16. Pulmonary function impairment in patients with combined pulmonary fibrosis and emphysema with and without airflow obstruction

    Directory of Open Access Journals (Sweden)

    Kitaguchi Y

    2014-07-01

    Full Text Available Yoshiaki Kitaguchi,1,2 Keisaku Fujimoto,3 Masayuki Hanaoka,1 Takayuki Honda,4 Junichi Hotta,2 Jiro Hirayama2 1First Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, 2Department of Internal Medicine, Okaya City Hospital, Okaya, 3Department of Clinical Laboratory Sciences, 4Department of Laboratory Medicine, Shinshu University School of Medicine, Matsumoto, Japan Background: The syndrome of combined pulmonary fibrosis and emphysema (CPFE is a recently described entity associating upper-lobe emphysema and lower-lobe fibrosis. We sought to evaluate differences in pulmonary function between CPFE patients with and without airflow obstruction. Subjects and methods: Thirty-one CPFE patients were divided into two groups according to the presence or absence of irreversible airflow obstruction based on spirometry (forced expiratory volume in 1 second/forced vital capacity <70% following inhalation of a β2-agonist as follows: CPFE patients with airflow obstruction (CPFE OB+ group, n=11, and CPFE patients without airflow obstruction (CPFE OB– group, n=20. Pulmonary function, including respiratory impedance evaluated using impulse oscillometry and dynamic hyperinflation following metronome-paced incremental hyperventilation, was retrospectively analyzed in comparison with that observed in 49 chronic obstructive pulmonary disease (COPD patients (n=49. Results: In imaging findings, low-attenuation-area scores on chest high-resolution computed tomography, representing the degree of emphysema, were significantly lower in the CPFE OB– group than in the CPFE OB+ and COPD groups. In contrast, the severity of pulmonary fibrosis was greater in the CPFE OB– group than in the CPFE OB+ group. In pulmonary function, lung hyperinflation was not apparent in the CPFE OB– group. Impairment of diffusion capacity was severe in both the CPFE OB– and CPFE OB+ groups. Impulse oscillometry showed that respiratory resistance was not

  17. Reconstruction of sound source signal by analytical passive TR in the environment with airflow

    Science.gov (United States)

    Wei, Long; Li, Min; Yang, Debin; Niu, Feng; Zeng, Wu

    2017-03-01

    In the acoustic design of air vehicles, the time-domain signals of noise sources on the surface of air vehicles can serve as data support to reveal the noise source generation mechanism, analyze acoustic fatigue, and take measures for noise insulation and reduction. To rapidly reconstruct the time-domain sound source signals in an environment with flow, a method combining the analytical passive time reversal mirror (AP-TR) with a shear flow correction is proposed. In this method, the negative influence of flow on sound wave propagation is suppressed by the shear flow correction, obtaining the corrected acoustic propagation time delay and path. Those corrected time delay and path together with the microphone array signals are then submitted to the AP-TR, reconstructing more accurate sound source signals in the environment with airflow. As an analytical method, AP-TR offers a supplementary way in 3D space to reconstruct the signal of sound source in the environment with airflow instead of the numerical TR. Experiments on the reconstruction of the sound source signals of a pair of loud speakers are conducted in an anechoic wind tunnel with subsonic airflow to validate the effectiveness and priorities of the proposed method. Moreover the comparison by theorem and experiment result between the AP-TR and the time-domain beamforming in reconstructing the sound source signal is also discussed.

  18. Prevalence of Airflow Limitation Defined by Pre- and Post-Bronchodilator Spirometry in a Community-Based Health Checkup: The Hisayama Study.

    Science.gov (United States)

    Fukuyama, Satoru; Matsumoto, Koichiro; Kaneko, Yasuko; Kan-o, Keiko; Noda, Naotaka; Tajiri-Asai, Yukari; Nakano, Takako; Ishii, Yumiko; Kiyohara, Yutaka; Nakanishi, Yoichi; Inoue, Hiromasa

    2016-02-01

    Spirometry in health checkup may contribute to early diagnosis of chronic obstructive pulmonary disease (COPD) and asthma. Although post-bronchodilator airflow limitation is essential for definite diagnosis of COPD and post-bronchodilator normalization of airflow is suggestive of asthma, this test has not been prevailed in health checkup. The objective of this study was to estimate the prevalence of airflow limitation defined by pre- and post-bronchodilator spirometry in health checkup. Post-bronchodilator spirometry was conducted for participants with airflow limitation in a town-wide health checkup for residents aged 40 years and older in Hisayama, a town in the western part of Japan. The prevalence of pre- and post-bronchodilator airway limitation defined by FEV1/FVC spirometry. In males, the age of current smokers was significantly younger than those of never smokers and former smokers. In females, the ages of current- and former smokers were significantly younger than never smokers. The values of %FEV1 and %FVC in current smokers were significantly lower than those in former smokers and never smokers. Two hundred sixty nine subjects, 85% of total subjects with a pre-bronchodilator FEV1/FVC spirometry. The prevalence of pre-bronchodilator airflow limitation was 14.6% in males and 13.7% in females, and the prevalence of post-bronchodilator airway limitation was 8.7% and 8.7%, respectively. Post-bronchodilator spirometry in health checkup would reduce the number of subjects with probable COPD to two-third. Recommendation for those examinees to take further evaluations may pave the way for early intervention.

  19. Characterization of dust particles produced in an all-tungsten wall tokamak and potentially mobilized by airflow

    Energy Technology Data Exchange (ETDEWEB)

    Rondeau, A., E-mail: anthony.rondeau@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES, SCA, 91192 Gif-sur-Yvette (France); Peillon, S.; Roynette, A.; Sabroux, J.-C.; Gelain, T.; Gensdarmes, F. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES, SCA, 91192 Gif-sur-Yvette (France); Rohde, V. [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany); Grisolia, C. [CEA, IRFM, 13108 Saint-Paul-lez-Durance (France); Chassefière, E. [Laboratoire Géosciences Paris Sud (GEOPS), UMR 8148, Université Paris Sud, 91403 Orsay Cedex (France)

    2015-08-15

    At the starting of the shutdown of the AUG (ASDEX Upgrade: Axially Symmetric Divertor EXperiment) German tokamak, we collected particles deposited on the divertor surfaces by means of a dedicated device called “Duster Box”. This device allows to collect the particles using a controlled airflow with a defined shear stress. Consequently, the particles collected correspond to a potentially mobilizable fraction, by an airflow, of deposited dust. A total of more than 70,000 tungsten particles was, analysed showing a bimodal particle size distribution with a mode composed of flakes at 0.6 μm and a mode composed of spherical particles at 1.8 μm.

  20. Synthesis of Fluorophore-Doped Polystyrene Microspheres: Seed Material for Airflow Sensing.

    Science.gov (United States)

    Wohl, Christopher J; Kiefer, Jacob M; Petrosky, Brian J; Tiemsin, Pacita I; Lowe, K Todd; Maisto, Pietro M F; Danehy, Paul M

    2015-09-23

    Kiton red 620 (KR620) doped polystyrene latex microspheres (PSLs) were synthesized via soap-free emulsion polymerization to be utilized as a relatively nontoxic, fluorescent seed material for airflow characterization experiments. Poly(styrene-co-styrenesulfonate) was used as the PSL matrix to promote KR620 incorporation. Additionally, a bicarbonate buffer and poly(diallyldimethylammonium chloride), polyD, cationic polymer were added to the reaction solution to stabilize the pH and potentially influence the electrostatic interactions between the PSLs and dye molecules. A design of experiments (DOE) approach was used to efficiently investigate the variation of these materials. Using a 4-factor, 2-level response surface design with a center point, a series of experiments were performed to determine the dependence of these factors on particle diameter, diameter size distribution, fluorescent emission intensity, and KR620 retention. Using statistical analysis, the factors and factor interactions that most significantly affect the outputs were identified. These particles enabled velocity measurements to be made much closer to walls and surfaces than previously. Based on these results, KR620-doped PSLs may be utilized to simultaneously measure the velocity and mixing concentration, among other airflow parameters, in complex flows.

  1. Main bronchial diverticula in the subcarinal region: Their relation to airflow limitations

    International Nuclear Information System (INIS)

    Higuchi, Takeshi; Takahashi, Naoya; Shiotani, Motoi; Sato, Suguru; Ohta, Atsushi; Maeda, Haruo; Nakajima, Haruhiko; Itoh, Kazuhiko; Tsukada, Hiroki

    2012-01-01

    Background. To date, bronchial diverticula have generally been treated as a pathological condition associated with chronic obstructive pulmonary disease (COPD), although only a limited amount of published information is available on the relationship between bronchial diverticula as depicted by multidetector computed tomography (MDCT) and airflow limitations. Purpose. To evaluate the relationship between airflow limitations and main bronchial diverticula in the subcarinal region using spirometry and thin-section MDCT. Material and Methods. A total of 189 consecutive adult patients were retrospectively evaluated based on spirometry and thin-section MDCT of the chest. All examinations were performed at our institution between June and October 2008. The study group included 70 women and 119 men with a mean age of 65 years (range 19-86 years). The relationship between the FEV1% and bronchial diverticula in the subcarinal region was analyzed (Student's t-test). Results. The indications for conducting the examinations were pulmonary diseases (82 patients), cardiovascular diseases (22), extrapulmonary malignancies (74), and other conditions (11). A total of 84/189 (44.4%) patients showed bronchial diverticula, and the FEV 1 % of 70/84 (83.3%) patients was above 70. The FEV 1 % of patients with lesions ranged from 26.0 to 97.8 (mean 76.8), whereas the range was 28.1-94.4 (mean 73.7) in those without lesions. There was no significant association between the FEV 1 % and the presence of subcarinal bronchial diverticula (P > 0.05). Conclusion. Our data demonstrate that thin-section chest CT commonly demonstrates main bronchial diverticula in the subcarinal region in patients without airflow limitations. We propose that the presence of a small number of tiny bronchial diverticula under the carina may not be a criterion for the diagnosis of COPD

  2. Main bronchial diverticula in the subcarinal region: Their relation to airflow limitations

    Energy Technology Data Exchange (ETDEWEB)

    Higuchi, Takeshi; Takahashi, Naoya; Shiotani, Motoi; Sato, Suguru; Ohta, Atsushi; Maeda, Haruo; Nakajima, Haruhiko; Itoh, Kazuhiko; Tsukada, Hiroki (Department of Radiology, Respiratory Medicine, Niigata City General Hospital, Niigata-city, Niigata-ken (Japan)), Email: higuchi@hosp.niigata.niigata.jp

    2012-02-15

    Background. To date, bronchial diverticula have generally been treated as a pathological condition associated with chronic obstructive pulmonary disease (COPD), although only a limited amount of published information is available on the relationship between bronchial diverticula as depicted by multidetector computed tomography (MDCT) and airflow limitations. Purpose. To evaluate the relationship between airflow limitations and main bronchial diverticula in the subcarinal region using spirometry and thin-section MDCT. Material and Methods. A total of 189 consecutive adult patients were retrospectively evaluated based on spirometry and thin-section MDCT of the chest. All examinations were performed at our institution between June and October 2008. The study group included 70 women and 119 men with a mean age of 65 years (range 19-86 years). The relationship between the FEV1% and bronchial diverticula in the subcarinal region was analyzed (Student's t-test). Results. The indications for conducting the examinations were pulmonary diseases (82 patients), cardiovascular diseases (22), extrapulmonary malignancies (74), and other conditions (11). A total of 84/189 (44.4%) patients showed bronchial diverticula, and the FEV{sub 1}% of 70/84 (83.3%) patients was above 70. The FEV{sub 1}% of patients with lesions ranged from 26.0 to 97.8 (mean 76.8), whereas the range was 28.1-94.4 (mean 73.7) in those without lesions. There was no significant association between the FEV{sub 1}% and the presence of subcarinal bronchial diverticula (P > 0.05). Conclusion. Our data demonstrate that thin-section chest CT commonly demonstrates main bronchial diverticula in the subcarinal region in patients without airflow limitations. We propose that the presence of a small number of tiny bronchial diverticula under the carina may not be a criterion for the diagnosis of COPD

  3. Airflow characteristics in the occupied zone of ventilated spaces

    DEFF Research Database (Denmark)

    Hanzawa, H.; Melikov, Arsen Krikor; Fanger, Povl Ole

    1987-01-01

    raft is one of the most common causes of complaint in ventilated or air-conditioned spaces. Therefore, knowing the turbulent airflow in these spaces and the impact of this flow on the sensation of draft is very important. The characteristics of turbulent flow (turbulence intensity, length scales...... of turbulence, turbulence kinetic energy, etc. ) were investigated in 20 typically ventilated spaces. Relationships between these characteristics and the mean velocity were found. The turbulence energy spectra are similar to those in a fully developed turbulent flow. The spectra reveal the major contribution...

  4. The association between chronic airflow obstruction and poverty in 12 sites of the multinational BOLD study.

    Science.gov (United States)

    Townend, John; Minelli, Cosetta; Mortimer, Kevin; Obaseki, Daniel O; Al Ghobain, Mohammed; Cherkaski, Hamid; Denguezli, Myriam; Gunesekera, Kirthi; Hafizi, Hasan; Koul, Parvaiz A; Loh, Li C; Nejjari, Chakib; Patel, Jaymini; Sooronbayev, Talant; Buist, Sonia A; Burney, Peter G J

    2017-06-01

    Poverty is strongly associated with mortality from COPD, but little is known of its relation to airflow obstruction.In a cross-sectional study of adults aged ≥40 years from 12 sites (N=9255), participating in the Burden of Obstructive Lung Disease (BOLD) study, poverty was evaluated using a wealth score (0-10) based on household assets. Obstruction, measured as forced expiratory volume in 1 s (FEV 1 )/forced vital capacity (FVC) (%) after administration of 200 μg salbutamol, and prevalence of FEV 1 /FVCwealth scores ranged from 4 in Blantyre (Malawi) and Kashmir (India) to 10 in Riyadh (Saudi Arabia), and the prevalence of obstruction, from 16% in Kashmir to 3% in Riyadh and Penang (Malaysia). Following adjustments for age and sex, FEV 1 /FVC increased by 0.36% (absolute change) (95%CI: 0.22, 0.49; pwealth score. Adjustments for other confounders reduced this effect to 0.23% (0.11, 0.34), but even this value remained highly significant (pwealth scores explained 38% of the variation in mean FEV 1 /FVC between sites (r 2 =0.385, p=0.031).Airflow obstruction is consistently associated with poverty at individual and community levels across several countries. Copyright ©ERS 2017.

  5. Mechanical Design of a Performance Test Rig for the Turbine Air-Flow Task (TAFT)

    Science.gov (United States)

    Forbes, John C.; Xenofos, George D.; Farrow, John L.; Tyler, Tom; Williams, Robert; Sargent, Scott; Moharos, Jozsef

    2004-01-01

    To support development of the Boeing-Rocketdyne RS84 rocket engine, a full-flow, reaction turbine geometry was integrated into the NASA-MSFC turbine air-flow test facility. A mechanical design was generated which minimized the amount of new hardware while incorporating all test and instrumentation requirements. This paper provides details of the mechanical design for this Turbine Air-Flow Task (TAFT) test rig. The mechanical design process utilized for this task included the following basic stages: Conceptual Design. Preliminary Design. Detailed Design. Baseline of Design (including Configuration Control and Drawing Revision). Fabrication. Assembly. During the design process, many lessons were learned that should benefit future test rig design projects. Of primary importance are well-defined requirements early in the design process, a thorough detailed design package, and effective communication with both the customer and the fabrication contractors.

  6. Controlling Object Heat Release Rate using Geometrical Features

    OpenAIRE

    Kraft, Stefan Marc

    2017-01-01

    An experimental study was conducted to determine the effect of complex geometries on the burning rate of materials made using additive manufacturing. Controlling heat release rate has applicability in limiting fire hazards as well as for designing fuels for optimal burning rate. The burning rate of a structure is a function of the material properties as well as the airflow through it, which is dictated by the geometry. This burning rate is generally proportional to the porosity for obj...

  7. Breathing life into dinosaurs: tackling challenges of soft-tissue restoration and nasal airflow in extinct species.

    Science.gov (United States)

    Bourke, Jason M; Porter, W M Ruger; Ridgely, Ryan C; Lyson, Tyler R; Schachner, Emma R; Bell, Phil R; Witmer, Lawrence M

    2014-11-01

    The nasal region plays a key role in sensory, thermal, and respiratory physiology, but exploring its evolution is hampered by a lack of preservation of soft-tissue structures in extinct vertebrates. As a test case, we investigated members of the "bony-headed" ornithischian dinosaur clade Pachycephalosauridae (particularly Stegoceras validum) because of their small body size (which mitigated allometric concerns) and their tendency to preserve nasal soft tissues within their hypermineralized skulls. Hypermineralization directly preserved portions of the olfactory turbinates along with an internal nasal ridge that we regard as potentially an osteological correlate for respiratory conchae. Fossil specimens were CT-scanned, and nasal cavities were segmented and restored. Soft-tissue reconstruction of the nasal capsule was functionally tested in a virtual environment using computational fluid dynamics by running air through multiple models differing in nasal soft-tissue conformation: a bony-bounded model (i.e., skull without soft tissue) and then models with soft tissues added, such as a paranasal septum, a scrolled concha, a branched concha, and a model combining the paranasal septum with a concha. Deviations in fluid flow in comparison to a phylogenetically constrained sample of extant diapsids were used as indicators of missing soft tissue. Models that restored aspects of airflow found in extant diapsids, such as appreciable airflow in the olfactory chamber, were judged as more likely. The model with a branched concha produced airflow patterns closest to those of extant diapsids. These results from both paleontological observation and airflow modeling indicate that S. validum and other pachycephalosaurids could have had both olfactory and respiratory conchae. Although respiratory conchae have been linked to endothermy, such conclusions require caution in that our re-evaluation of the reptilian nasal apparatus indicates that respiratory conchae may be more widespread

  8. Using Coupled Energy, Airflow and IAQ Software (TRNSYS/CONTAM) to Evaluate Building Ventilation Strategies.

    Science.gov (United States)

    Dols, W Stuart; Emmerich, Steven J; Polidoro, Brian J

    2016-03-01

    Building energy analysis tools are available in many forms that provide the ability to address a broad spectrum of energy-related issues in various combinations. Often these tools operate in isolation from one another, making it difficult to evaluate the interactions between related phenomena and interacting systems, forcing oversimplified assumptions to be made about various phenomena that could otherwise be addressed directly with another tool. One example of such interdependence is the interaction between heat transfer, inter-zone airflow and indoor contaminant transport. In order to better address these interdependencies, the National Institute of Standards and Technology (NIST) has developed an updated version of the multi-zone airflow and contaminant transport modelling tool, CONTAM, along with a set of utilities to enable coupling of the full CONTAM model with the TRNSYS simulation tool in a more seamless manner and with additional capabilities that were previously not available. This paper provides an overview of these new capabilities and applies them to simulating a medium-size office building. These simulations address the interaction between whole-building energy, airflow and contaminant transport in evaluating various ventilation strategies including natural and demand-controlled ventilation. CONTAM has been in practical use for many years allowing building designers, as well as IAQ and ventilation system analysts, to simulate the complex interactions between building physical layout and HVAC system configuration in determining building airflow and contaminant transport. It has been widely used to design and analyse smoke management systems and evaluate building performance in response to chemical, biological and radiological events. While CONTAM has been used to address design and performance of buildings implementing energy conserving ventilation systems, e.g., natural and hybrid, this new coupled simulation capability will enable users to apply the

  9. Model Experiments for the Determination of Airflow in Large Spaces

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    Model experiments are one of the methods used for the determination of airflow in large spaces. This paper will discuss the formation of the governing dimensionless numbers. It is shown that experiments with a reduced scale often will necessitate a fully developed turbulence level of the flow....... Details of the flow from supply openings are very important for the determination of room air distribution. It is in some cases possible to make a simplified supply opening for the model experiment....

  10. Collection and identification of human remains volatiles by non-contact, dynamic airflow sampling and SPME-GC/MS using various sorbent materials.

    Science.gov (United States)

    DeGreeff, Lauryn E; Furton, Kenneth G

    2011-09-01

    Human remains detection canines are used in locating deceased humans in diverse scenarios and environments based on odor produced during the decay process of the human body. It has been established that human remains detection canines are capable of locating human remains specifically, as opposed to living humans or animal remains, thus suggesting a difference in odor between the different sources. This work explores the collection and determination of such odors using a dynamic headspace concentration device. The airflow rate and three sorbent materials-Dukal cotton gauze, Johnson & Johnson cotton-blend gauze, and polyester material-used for odor collection were evaluated using standard compounds. It was determined that higher airflow rates and openly woven material, e.g., Dukal cotton gauze, yielded significantly less total volatile compounds due to compound breakthrough through the sorbent material. Collection from polymer- and cellulose-based materials demonstrated that the molecular backbone of the material is a factor in compound collection as well. Volatiles, including cyclic and straight-chain hydrocarbons, organic acids, sulfides, aldehydes, ketones, and alcohols, were collected from a population of 27 deceased bodies from two collection locations. The common compounds between the subjects were compared and the odor profiles were determined. These odor profiles were compared with those of animal remains and living human subjects collected in the same manner. Principal component analysis showed that the odor profiles of the three sample types were distinct.

  11. Coupling fast fluid dynamics and multizone airflow models in Modelica Buildings library to simulate the dynamics of HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Wei [Univ. of Miami, FL (United States). Dept. of Civil, Architectural and Environmental Engineering; Sevilla, Thomas Alonso [Univ. of Miami, FL (United States). Dept. of Civil, Architectural and Environmental Engineering; Zuo, Wangda [Univ. of Miami, FL (United States). Dept. of Civil, Architectural and Environmental Engineering; Sohn, Michael D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.

    2017-06-08

    Historically, multizone models are widely used in building airflow and energy performance simulations due to their fast computing speed. However, multizone models assume that the air in a room is well mixed, consequently limiting their application. In specific rooms where this assumption fails, the use of computational fluid dynamics (CFD) models may be an alternative option. Previous research has mainly focused on coupling CFD models and multizone models to study airflow in large spaces. While significant, most of these analyses did not consider the coupled simulation of the building airflow with the building's Heating, Ventilation, and Air-Conditioning (HVAC) systems. This paper tries to fill the gap by integrating the models for HVAC systems with coupled multizone and CFD simulations for airflows, using the Modelica simul ation platform. To improve the computational efficiency, we incorporated a simplified CFD model named fast fluid dynamics (FFD). We first introduce the data synchronization strategy and implementation in Modelica. Then, we verify the implementation using two case studies involving an isothermal and a non-isothermal flow by comparing model simulations to experiment data. Afterward, we study another three cases that are deemed more realistic. This is done by attaching a variable air volume (VAV) terminal box and a VAV system to previous flows to assess the capability of the models in studying the dynamic control of HVAC systems. Finally, we discuss further research needs on the coupled simulation using the models.

  12. Improved inhaled air quality at reduced ventilation rate by control of airflow interaction at the breathing zone with lobed jets

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Spilak, Michal

    2014-01-01

    Inhaled air quality at a reduced supply of clean air was studied by controlling the airflow interaction at the breathing zone of a person using lobed jets as part of personalized ventilation (PV). Experiments were performed in a full-scale test room at 23°C (73.4°F) with a breathing thermal manikin...... seated at a workstation, with realistic free-convection flow around the body and a normal breathing cycle. The air in the room was mixed with tracer gas R134a. Clean air was supplied isothermally from three nozzles with circular, four-leafed clover, and six-edged star openings of 0.025 m (0.08 ft...... over the interaction between the inserted jets and the free convection flow was efficient. Over 80% clean PV air was measured in inhalation. The worst performing nozzle was the four-leafed clover: its best performance yielded 23% clean air inhalation, at the shortest distance and the highest velocity...

  13. Poppet valve control of throat stability bypass to increase stable airflow range of a Mach 2.5. inlet with 60 percent internal contraction

    Science.gov (United States)

    Mitchell, G. A.; Sanders, B. W.

    1975-01-01

    The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. System variations included several stability bypass entrance configurations. Poppet valves controlled the bypass airflow. The inlet stable airflow range achieved with each configuration was determined for both steady state conditions and internal pulse transients. Results are compared with those obtained without a stability bypass system. Transient results were also obtained for the inlet with a choke point at the diffuser exit and for the inlet with large and small stability bypass plenum volumes. Poppet valves at the stability bypass exit provided the inlet with a stable airflow range of 20 percent or greater at all static and transient conditions.

  14. A Computational Study of the Respiratory Airflow Characteristics in Normal and Obstructed Human Airways

    Science.gov (United States)

    2014-01-01

    46] Y.S. Tzeng, K. Lutchen, M. Albert , The difference in ventilation heterogeneity between asthmatic and healthy subjects quantified using...endurance and diaphragmatic activation in patients with chronic airflow limitation, Thorax 44 (1989) 903–912. [52] V.K. Sidhaye, K.S. Schweitzer , M.J

  15. Canthaxanthin biosynthesis by Dietzia natronolimnaea HS-1: effects of inoculation and aeration rate

    Directory of Open Access Journals (Sweden)

    Forouzan Rostami

    2014-06-01

    Full Text Available The interest in production of natural colorants by microbial fermentation has been currently increased. The effects of D-glucose concentration (3.18-36.82 g/L, inoculum size (12.5 x 10(9-49.5 x 10(9 cfu cells/mL and air-flow rate (1.95-12.05 L/L min on the biomass, total carotenoid and canthaxanthin (CTX accumulation of Dietzia natronolimnaea HS-1 in a batch bioreactor was scrutinized using a response surface methodology-central composite rotatable design (RSM-CCRD. Second-order polynomial models with high R² values ranging from 0.978 to 0.990 were developed for the studied responses using multiple linear regression analysis. The models showed the maximum cumulative amounts of biomass (7.85 g/L, total carotenoid (5.48 mg/L and CTX (4.99 mg/L could be achieved at 23.38 g/L of D-glucose, 31.2 x 10(9 cfu cells/mL of inoculation intensity and air-flow rate of 7.85 L/L min. The predicted values for optimum conditions were in good agreement with experimental data.

  16. Surface potential distribution and airflow performance of different air-exposed electrode plasma actuators at different alternating current/direct current voltages

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Liang; Yan, Hui-Jie; Qi, Xiao-Hua; Hua, Yue; Ren, Chun-Sheng, E-mail: rchsh@dlut.edu.cn [School of Physics and Optoelectronic Technology, Key laboratory of Materials Modification by Laser, Ion and Electron Beams, Ministry of Education, Dalian University of Technology, Dalian 116023 (China)

    2015-04-15

    Asymmetric surface dielectric barrier discharge (SDBD) plasma actuators have been intensely studied for a number of years due to their potential applications for aerodynamic control. In this paper, four types of actuators with different configurations of exposed electrode are proposed. The SDBD actuators investigated are driven by dual-power supply, referred to as a fixed AC high voltage and an adjustable DC bias. The effects of the electrode structures on the dielectric surface potential distribution, the electric wind velocity, and the mean thrust production are studied, and the dominative factors of airflow acceleration behavior are revealed. The results have shown that the actions of the SDBD actuator are mainly dependent on the geometry of the exposed electrode. Besides, the surface potential distribution can effectively affect the airflow acceleration behavior. With the application of an appropriate additional DC bias, the surface potential will be modified. As a result, the performance of the electric wind produced by a single SDBD can be significantly improved. In addition, the work also illustrates that the actuators with more negative surface potential present better mechanical performance.

  17. Surface potential distribution and airflow performance of different air-exposed electrode plasma actuators at different alternating current/direct current voltages

    International Nuclear Information System (INIS)

    Yang, Liang; Yan, Hui-Jie; Qi, Xiao-Hua; Hua, Yue; Ren, Chun-Sheng

    2015-01-01

    Asymmetric surface dielectric barrier discharge (SDBD) plasma actuators have been intensely studied for a number of years due to their potential applications for aerodynamic control. In this paper, four types of actuators with different configurations of exposed electrode are proposed. The SDBD actuators investigated are driven by dual-power supply, referred to as a fixed AC high voltage and an adjustable DC bias. The effects of the electrode structures on the dielectric surface potential distribution, the electric wind velocity, and the mean thrust production are studied, and the dominative factors of airflow acceleration behavior are revealed. The results have shown that the actions of the SDBD actuator are mainly dependent on the geometry of the exposed electrode. Besides, the surface potential distribution can effectively affect the airflow acceleration behavior. With the application of an appropriate additional DC bias, the surface potential will be modified. As a result, the performance of the electric wind produced by a single SDBD can be significantly improved. In addition, the work also illustrates that the actuators with more negative surface potential present better mechanical performance

  18. Non-atopic males with adult onset asthma are at risk of persistent airflow limitation

    NARCIS (Netherlands)

    Amelink, M.; de Nijs, S. B.; Berger, M.; Weersink, E. J.; ten Brinke, A.; Sterk, P. J.; Bel, E. H.

    2012-01-01

    Background Patients with asthma have on average a more rapid decline in FEV1 as compared with the general population. Recent cluster analysis has revealed different asthma phenotypes that can be distinguished by age of onset and reversibility of airflow limitation. Objective This study aimed at

  19. Effect of Airflow Velocity on Pre-cooling Process of Pomegranate by Forced Cooling Air under Unsteady State Heat Transfer Condition

    Directory of Open Access Journals (Sweden)

    M. A Behaeen

    2018-03-01

    . Also, half-cooling time and seven-eighths cooling time reduced and so cooling rate enhanced. Thus, despite a reduction lag factor, due to a significant increase in cooling coefficient, half and seven-eighths cooling declined. Dimensionless temperature, θ, less than 0.2 and 0.1 in the center and peel and at different velocities had little impact on the rate of cooling in pomegranate. The difference in primary cooling time (0-500 sec and in high lag factor (greater than 1 occurred, which represents an internal resistance of heat transfer in fruit against the airflow. Cooling the center of pomegranate starts with time delay which causes the beginning of the cooling curve becomes flat. Seven-eighths cooling time is the part of half-cooling time. The range of S was 2.5-3.5H in the present study. At first, cooling heterogeneity at 0.5 m s-1 was low in the center and peel of pomegranate and then with increasing the velocity up to 1 m s-1, it enhanced and again decreased at 1.3 m s-1. After a period of cooling (5000 sec, almost layers of pomegranate reached the same temperature and so heterogeneity reduced. The maximum instantaneous cooling rate was 8.09 × 10-4 ºC s-1 at 1.3 m s-1 in the center of pomegranate. By increasing the airflow velocity from 0.5 to 1.3 m s-1, the convective heat transfer coefficient increased from 11.05 to 17.51 W m-2 K-1. Therefore, the velocity of cold air is an important factor in variation of convective heat transfer coefficient. Conclusions Cooling efficiency is evaluated based on rapid and uniformity of cooling. Cooling curves against time reduced exponentially at the different airflow velocities in the center (aril and outer layer (peel of pomegranate. By increasing the air flow velocity, half and seven-eighths cooling time reduced and cooling rate increased that showed direct impact of this variable. The main reason was the variation of convective heat transfer coefficient. The lowest level of uniformity obtained at the highest velocity (1

  20. Comparison of pulmonary function in patients with COPD, asthma-COPD overlap syndrome, and asthma with airflow limitation.

    Science.gov (United States)

    Kitaguchi, Yoshiaki; Yasuo, Masanori; Hanaoka, Masayuki

    2016-01-01

    This study was conducted in order to investigate the differences in the respiratory physiology of patients with chronic obstructive pulmonary disease (COPD), asthma-COPD overlap syndrome (ACOS), and asthma with airflow limitation (asthma FL(+)). The medical records for a series of all stable patients with persistent airflow limitation due to COPD, ACOS, or asthma were retrospectively reviewed and divided into the COPD group (n=118), the ACOS group (n=32), and the asthma FL(+) group (n=27). All the patients underwent chest high-resolution computed tomography (HRCT) and pulmonary function tests, including respiratory impedance. The low attenuation area score on chest HRCT was significantly higher in the COPD group than in the ACOS group (9.52±0.76 vs 5.09±1.16, Pbronchial wall thickening on chest HRCT was significantly higher in the asthma FL(+) group than in the COPD group (55.6% vs 25.0%, P<0.01). In pulmonary function, forced expiratory volume in 1 second (FEV1) and peak expiratory flow rate were significantly higher in the asthma FL(+) group than in the ACOS group (76.28%±2.54% predicted vs 63.43%±3.22% predicted, P<0.05 and 74.40%±3.16% predicted vs 61.08%±3.54% predicted, P<0.05, respectively). Although residual volume was significantly lower in the asthma FL(+) group than in the COPD group (112.05%±4.34% predicted vs 137.38%±3.43% predicted, P<0.01) and the ACOS group (112.05%±4.34% predicted vs148.46%±6.25% predicted, P<0.01), there were no significant differences in functional residual capacity or total lung capacity. The increase in FEV1 in response to short-acting β2-agonists was significantly greater in the ACOS group than in the COPD group (229±29 mL vs 72±10 mL, P<0.01) and the asthma FL(+) group (229±29 mL vs 153±21 mL, P<0.05). Regarding respiratory impedance, resistance at 5 Hz and resistance at 20 Hz, which are oscillatory parameters of respiratory resistance, were significantly higher in the asthma FL(+) group than in the COPD group

  1. Impact of Thermal Plumes Generated by Occupant Simulators with Different Complexity of Body Geometry on Airflow Pattern in Rooms

    DEFF Research Database (Denmark)

    Zukowska, Daria; Melikov, Arsen Krikor; Popiolek, Zbigniew

    2008-01-01

    The impact of thermal plumes generated by human body simulators with different geometry on the airflow pattern in a full scale room with displacement ventilation (supply air temperature 21.6°C, total flow rate 80 L/s) was studied when two seated occupants were simulated first by two thermal...... manikins resembling accurately human body shape and then by two heated cylinders. The manikins and the cylinders had the same surface area of 1.63 m2 and the same heat generation of 73 W. CO2 supplied from the top of the heat sources was used for simulating bio-effluents. CO2 concentration was measured...

  2. Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows

    NARCIS (Netherlands)

    Schreur, H. J.; Sterk, P. J.; Vanderschoot, J.; van Klink, H. C.; van Vollenhoven, E.; Dijkman, J. H.

    1992-01-01

    A common auscultatory finding in pulmonary emphysema is a reduction of lung sounds. This might be due to a reduction in the generation of sounds due to the accompanying airflow limitation or to poor transmission of sounds due to destruction of parenchyma. Lung sound intensity was investigated in

  3. Effect of laminar airflow ventilation on surgical site infections: a systematic review and meta-analysis.

    Science.gov (United States)

    Bischoff, Peter; Kubilay, N Zeynep; Allegranzi, Benedetta; Egger, Matthias; Gastmeier, Petra

    2017-05-01

    The role of the operating room's ventilation system in the prevention of surgical site infections (SSIs) is widely discussed, and existing guidelines do not reflect current evidence. In this context, laminar airflow ventilation was compared with conventional ventilation to assess their effectiveness in reducing the risk of SSIs. We searched MEDLINE, Embase, Cochrane Central Register of Controlled Trials, and WHO regional medical databases from Jan 1, 1990, to Jan 31, 2014. We updated the search for MEDLINE for the period between Feb 1, 2014, and May 25, 2016. We included studies most relevant to our predefined question: is the use of laminar airflow in the operating room associated with the reduction of overall or deep SSI as outcomes in patients of any age undergoing surgical operations? We excluded studies not relevant to the study question, studies not in the selected languages, studies published before Jan 1, 1990, or after May 25, 2016, meeting or conference abstracts, and studies of which the full text was not available. Data were extracted by two independent investigators, with disagreements resolved through further discussion. Authors were contacted if the full-text article was not available, or if important data or information on the paper's content was absent. Studies were assessed for publication bias. Grading of recommendations assessment, development, and evaluation was used to assess the quality of the identified evidence. Meta-analyses were done with RevMan (version 5.3). We identified 1947 records of which 12 observational studies were comparing laminar airflow ventilation with conventional turbulent ventilation in orthopaedic, abdominal, and vascular surgery. The meta-analysis of eight cohort studies showed no difference in risk for deep SSIs following total hip arthroplasty (330 146 procedures, odds ratio [OR] 1·29, 95% CI 0·98-1·71; p=0·07, I 2 =83%). For total knee arthroplasty, the meta-analysis of six cohort studies showed no difference

  4. Field measurements of mean and turbulent airflow over a barchan sand dune

    Science.gov (United States)

    Weaver, Corinne M.; Wiggs, Giles F. S.

    2011-05-01

    Advances in our knowledge of the aeolian processes governing sand dune dynamics have been restricted by a reliance on measures of time-averaged airflow, such as shear velocity ( u*). It has become clear that such measures are incapable of explaining the complete dynamics of sediment transport across dune surfaces. Past evidence from wind tunnel and modelling studies has suggested that in some regions on a dune's surface the sediment transport might be better explained through investigations of the turbulent nature of the airflow. However, to date there have been no field studies providing data on the turbulent characteristics of the airflow around dunes with which to support or refute such hypotheses. The field investigation presented here provides mean and turbulent airflow measurements across the centre-line of a barchan sand dune in Namibia. Data were collected using arrays of sonic anemometers and were compared with sand flux data measured using wedge-shaped traps. Results support previously published data derived from wind tunnels and numerical models. The decline in mean wind velocity at the upwind toe of the dune is shown to coincide with a rise in turbulence, whilst mean velocity acceleration on the upper slope corresponds with a general decline in measured turbulence. Analysis of the components of Reynold shear stress ( -u'¯w'¯) and normal stresses ( u¯ and w2 ¯) supports the notion that the development of flow turbulence along the dune centre-line is likely to be associated with the interplay between streamline curvature and mean flow deceleration/acceleration. It is suggested that, due to the nature of its calculation, turbulence intensity is a measure of less practical use than direct assessments of the individual components of Reynolds stress, particularly the instantaneous horizontal streamwise component ( u2 ¯) and shear stress ( -uw¯). Whilst, increases in Reynolds shear stress and the horizontal streamwise component of stress in the toe

  5. Awareness and prevalence of acute mountain sickness and prevalence of obstructive airflow limitation among Nepalese porters: A cross-sectional study in Khumbu Valley, Nepal

    OpenAIRE

    Parajuli, Ranjan

    2009-01-01

    Background: Acute mountain sickness is a major public health problem in high altitudes. Similarly, anecdotal evidence suggests that there is high prevalence of tobacco smoking among this group though prevalence of obstructive airflow limitation is not known. Objectives: The main aims of the study were to measure the awareness of AMS and report the prevalence of AMS and obstructive lung diseases in high altitude Nepalese porters. Setting: This study was done with bases in Namche Bazaar (...

  6. The effect of airflow on thermographically determined temperature of the distal forelimb of the horse.

    Science.gov (United States)

    Westermann, S; Stanek, C; Schramel, J P; Ion, A; Buchner, H H F

    2013-09-01

    Current literature suggests that thermographic imaging of horses should be performed in a draught-free room. However, studies on the effect of airflow on determined temperature have not been published. To investigate effects of airflow on thermographically determined temperature of horses' forelimbs; to assess the relationship of wind velocity, rectal temperature, ambient temperature and humidity. Thermographic images were obtained for the forelimbs of 6 horses in a draught-free room. Three replicates (R) with defined wind velocities (R1, 0.5-1.0 m/s; R2, 1.3-2.6 m/s; and R3, 3.0-4.0 m/s) were conducted. Each replicate consisted of a baseline image, a 15 min phase with the wind on and a 15 min phase with the wind off. We exposed only the right leg to airflow and determined the temperature by thermography with the wind on and wind off. Temperature differences between baseline and wind on, between wind on and wind off and between different wind velocities were analysed by a general linear model, Student's paired t test and ANOVA. After the onset of wind, the temperature on the right forelimb decreased within 1-3 min (by approximately 0.6°C at R1, 1.5°C at R2 and 2.1°C at R3). With the wind off, the temperature increased within 3 min (by approximately 1.2°C at R1, 1.7°C at R2 and 2.1°C at R3). With increasing wind velocity, the temperature differences between baseline and wind on and between wind on and wind off increased significantly. Barely noticeable wind velocities caused a decrease in thermographically determined temperatures of the forelimbs of the horse. Further research is required to assess the influence of airflow on other parts of the body and at different ambient temperatures, as well as the effect on horses with inflammatory lesions, especially of the distal limbs. It is essential for practitioners to perform thermography on horses in a draught-free environment in order to avoid false-positive or -negative diagnoses. © 2012 EVJ Ltd.

  7. Occupational exposure to vapor, gas, dust, or fumes and chronic airflow limitation, COPD, and emphysema: the Swedish CArdioPulmonary BioImage Study (SCAPIS pilot

    Directory of Open Access Journals (Sweden)

    Torén K

    2017-11-01

    Full Text Available Kjell Torén,1 Jenny Vikgren,2 Anna-Carin Olin,1 Annika Rosengren,3 Göran Bergström,3 John Brandberg2 1Section of Occupational and Environmental Medicine, Institute of Medicine, Sahlgrenska Academy, 2Department of Radiology, Institute of Clinical Sciences, 3Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden Background: The aim of this study was to estimate the occupational burden of airflow limitation, chronic airflow limitation, COPD, and emphysema.Materials and methods: Subjects aged 50–64 years (n=1,050 were investigated with forced expiratory volume in 1 s (FEV1 and forced vital capacity (FVC. Airflow limitation was defined as FEV1/FVC <0.7 before bronchodilation. Chronic airflow limitation was defined after bronchodilation either according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD as FEV1/FVC <0.7 or according to the lower limit of normal (LLN approach as FEV1/FVC < LLN. COPD was defined as chronic airflow limitation (GOLD in combination with dyspnea, wheezing, or chronic bronchitis. Emphysema was classified according to findings from computed tomography of the lungs. Occupational exposure was defined as self-reported occupational exposure to vapor, gas, dust, or fumes (VGDF. Odds ratios (OR were calculated in models adjusted for age, gender, and smoking; population-attributable fractions and 95% CI were also calculated.Results: There were significant associations between occupational exposure to VGDF and COPD (OR 2.7, 95% CI 1.4–51, airflow limitation (OR 1.8, 95% CI 1.3–2.5, and emphysema (OR 1.8, 95% CI 1.1–3.1. The associations between occupational exposure to VGDF and chronic airflow limitation were weaker, and for the OR, the CIs included unity. The population-attributable fraction for occupational exposure to VGDF was 0.37 (95% CI 0.23–0.47 for COPD and 0.23 (95% CI 0.05–0.35 for emphysema.Conclusion: The

  8. Air-flow resistances of silicone rubber voice prostheses after formation of bacterial and fungal biofilms

    NARCIS (Netherlands)

    Elving, GJ; van der Mei, HC; Busscher, HJ; van Weissenbruch, R; Albers, FWJ

    Laryngectomized patients use silicone rubber voice prostheses to rehabilitate their voice. However, biofilm formation limits the lifetime of voice prostheses by causing leakage or an increased air-flow resistance and the prosthesis has to be replaced. To determine which bacterial or yeast strains,

  9. Airflow and Heat Transfer in the Slot-Vented Room with Radiant Floor Heating Unit

    Directory of Open Access Journals (Sweden)

    Xiang-Long Liu

    2012-01-01

    Full Text Available Radiant floor heating has received increasing attention due to its diverse advantages, especially the energy saving as compared to the conventional dwelling heating system. This paper presents a numerical investigation of airflow and heat transfer in the slot-vented room with the radiant floor heating unit. Combination of fluid convection and thermal radiation has been implemented through the thermal boundary conditions. Spatial distributions of indoor air temperature and velocity, as well as the heat transfer rates along the radiant floor and the outer wall, have been presented and analyzed covering the domains from complete natural convection to forced convection dominated flows. The numerical results demonstrate that the levels of average temperature in the room with lateral slot-ventilation are higher than those without slot-ventilation, but lower than those in the room with ceiling slot-ventilation. Overall, the slot-ventilation room with radiant floor heating unit could offer better indoor air quality through increasing the indoor air temperature and fresh air exchanging rate simultaneously. Concerning the airborne pollutant transports and moisture condensations, the performance of radiant floor heating unit will be further optimized in our future researches.

  10. Nocturnal airflow obstruction, histamine, and the autonomic central nervous system in children with allergic asthma

    NARCIS (Netherlands)

    van Aalderen, W. M.; Postma, D. S.; Koëter, G. H.; Knol, K.

    1991-01-01

    A study was carried out to investigate whether an imbalance in the autonomic nervous system or release of histamine, or both, is responsible for the nocturnal increase in airflow obstruction in asthmatic children. The study comprised 18 children with allergic asthma, nine with (group 1) and nine

  11. Airflow Characteristics at the Breathing Zone of a Seated Person

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Bolashikov, Zhecho Dimitrov; Nagano, Hideaki

    2011-01-01

    A method for active control over the interaction between the free convection flow around occupant‘s body and locally applied airflow from front on the velocity field at the breathing zone of a seated person was studied. A workplace equipped with personalised ventilation (PV) generating flow from......) was installed below the table board, above the thighs of the manikin, and was used to exhaust the air of the free convection flow coming from the lower body parts of the manikin. The velocity field at the breathing zone was measured with Particle Image Velocimetry consisting of a dual cavity laser and two CCD...

  12. Collective Odor Source Estimation and Search in Time-Variant Airflow Environments Using Mobile Robots

    Science.gov (United States)

    Meng, Qing-Hao; Yang, Wei-Xing; Wang, Yang; Zeng, Ming

    2011-01-01

    This paper addresses the collective odor source localization (OSL) problem in a time-varying airflow environment using mobile robots. A novel OSL methodology which combines odor-source probability estimation and multiple robots’ search is proposed. The estimation phase consists of two steps: firstly, the separate probability-distribution map of odor source is estimated via Bayesian rules and fuzzy inference based on a single robot’s detection events; secondly, the separate maps estimated by different robots at different times are fused into a combined map by way of distance based superposition. The multi-robot search behaviors are coordinated via a particle swarm optimization algorithm, where the estimated odor-source probability distribution is used to express the fitness functions. In the process of OSL, the estimation phase provides the prior knowledge for the searching while the searching verifies the estimation results, and both phases are implemented iteratively. The results of simulations for large-scale advection–diffusion plume environments and experiments using real robots in an indoor airflow environment validate the feasibility and robustness of the proposed OSL method. PMID:22346650

  13. Measuring Airflow in Local Exhaust Ventilation Systems. Module 23. Vocational Education Training in Environmental Sciences.

    Science.gov (United States)

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on measuring airflow in local exhaust ventilation systems. Following guidelines for students and instructors and an introduction that explains what the student will learn are three lessons: (1) naming each…

  14. Adenosine 5'-Monophosphate Aerosol Challenge Does Not Provoke Airflow Limitation in Healthy Cats

    Directory of Open Access Journals (Sweden)

    K. Vondráková

    2006-01-01

    Full Text Available The purpose of our study was to investigate the effects of nebulized adenosine 5'- monophosphate on airflow limitation in healthy cats determined by barometric whole body plethysmography (BWBP, in comparison to the effects of carbachol. Ten healthy 4- to 6-year-old domestic shorthair cats were included in the study. Each cat was placed in a BWBP plexiglass chamber (volume 38 l. Changes in box pressure were measured at baseline and after nebulization of vehicle and increasing concentrations of carbachol and adenosine 5'- monophosphate. Airway responsiveness was monitored as increases in enhanced pause (PENH, a unitless variable derived from dose-response curves estimating airflow limitation. The chosen endpoint was the agonist concentration which increased PENH to 300% of the value obtained after saline nebulization (PCPENH 300. Inter-day repeatability of measurements was assessed by repeated bronchoprovocations with both agonists 2-3 days apart. For carbachol, PCPENH300 was reached in all cats and correlated significantly between days (mean ± SD; 0.54 ± 0.42 mg/ml and 0.64 ± 0.45 mg/ml respectively; r = 0.58, p < 0.05 In contrast, we found no reaction to adenosine 5'- monophosphate even with the highest concentration nebulized during both measurements. At baseline, mean ± SD PENH was 0.47 ± 0.18 and 0.58 ± 0.24 (measurements 1 and 2, whereas PENH after 500 mg/ml adenosine 5'- monophosphate was 0.46 ± 0.20 and 0.71 ± 0.37. All bronchoprovocation tests were well tolerated by the cats. We conclude that healthy airways in cats do not demonstrate airway responsiveness to inhaled adenosine 5'- monophosphate. This is in agreement with observations in humans as well as our previous findings in dogs, where adenosine 5'- monophosphate had no effect on healthy canine airways, but caused significant airflow limitation after induction of acute bronchitis. To define the value of bronchoprovocation testing with adenosine 5'- monophosphate in the feline

  15. Airflow limitation in people living with HIV and matched uninfected controls

    DEFF Research Database (Denmark)

    Ronit, Andreas; Lundgren, Jens; Afzal, Shoaib

    2018-01-01

    -matched controls from the Copenhagen General Population Study were included. Lung function was assessed using FEV1 and FVC, while airflow limitation was defined by the lower limit of normal (LLN) of FEV1/FVC and by FEV1/FVClinear regression models were used......INTRODUCTION: Whether HIV influences pulmonary function remains controversial. We assessed dynamic pulmonary function in people living with HIV (PLWHIV) and uninfected controls. METHODS: A total of 1098 PLWHIV from the Copenhagen Co-morbidity in HIV infection study and 12 161 age-matched and sex...

  16. Airflow structures and nano-particle deposition in a human upper airway model

    Science.gov (United States)

    Zhang, Z.; Kleinstreuer, C.

    2004-07-01

    Considering a human upper airway model, or equivalently complex internal flow conduits, the transport and deposition of nano-particles in the 1-150 nm diameter range are simulated and analyzed for cyclic and steady flow conditions. Specifically, using a commercial finite-volume software with user-supplied programs as a solver, the Euler-Euler approach for the fluid-particle dynamics is employed with a low-Reynolds-number k- ω model for laminar-to-turbulent airflow and the mass transfer equation for dispersion of nano-particles or vapors. Presently, the upper respiratory system consists of two connected segments of a simplified human cast replica, i.e., the oral airways from the mouth to the trachea (Generation G0) and an upper tracheobronchial tree model of G0-G3. Experimentally validated computational fluid-particle dynamics results show the following: (i) transient effects in the oral airways appear most prominently during the decelerating phase of the inspiratory cycle; (ii) selecting matching flow rates, total deposition fractions of nano-size particles for cyclic inspiratory flow are not significantly different from those for steady flow; (iii) turbulent fluctuations which occur after the throat can persist downstream to at least Generation G3 at medium and high inspiratory flow rates (i.e., Qin⩾30 l/min) due to the enhancement of flow instabilities just upstream of the flow dividers; however, the effects of turbulent fluctuations on nano-particle deposition are quite minor in the human upper airways; (iv) deposition of nano-particles occurs to a relatively greater extent around the carinal ridges when compared to the straight tubular segments in the bronchial airways; (v) deposition distributions of nano-particles vary with airway segment, particle size, and inhalation flow rate, where the local deposition is more uniformly distributed for large-size particles (say, dp=100 nm) than for small-size particles (say, dp=1 nm); (vi) dilute 1 nm particle

  17. The usefulness of computed tomography in distinguishing between asthma with irreversible air-flow limitation and pulmonary emphysema

    International Nuclear Information System (INIS)

    Taniguchi, Hiroyuki; Ogawa, Kenji; Nakajima, Yoko; Amano, Masao; Kondo, Yasuhiro; Matsumoto, Kohei; Yokoyama, Sigeki; Matsubara, Kazuhito

    1988-01-01

    Chronic asthma may develop irreversible air-flow limitation and in this circumstance, it is clinically difficult to distinguish between asthma and pulmonary emphysema. Recently, it has been reported that computed tomography (CT) may assist in detecting changes in the lung specific for emphysema. We examined patients who suffered from asthma before the age of 45 which led to irreversible air-flow limitation (BA group; n = 17, mean age = 65.9) and patients with pulmonary emphysema (CPE group; n = 19, mean age = 69.8). Pulmonary function testing and CT were performed on all patients. In assessment of CT, areas of low attenuation and vascular disruption were considered to be suggestive of emphysema, and the Emphysema Score (ES) was calculated according to the method of Bergin et al. There was no significant difference in FEV1.0, % FEV1.0, % FEV1.0/FVC, % RV and RV/TLC between the BA group and the CPE group. In contrast, there was a significant decrease in the % DLco in CPE group compared with that of the BA group (p < 0.001). The ES in total lung was 54.9 ± 18.6 % in the CPE group and 7.8 ± 11.0 % in BA group (p < 0.001). There was a significant correlation between the % DLco and the ES in the CPE group (p < 0.01). We conclude that the CT is useful in distinguishing between asthma with irreversible air-flow limitation and pulmonary emphysema. (author)

  18. 42 CFR 84.157 - Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum...

    Science.gov (United States)

    2010-10-01

    ... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH...

  19. 42 CFR 84.156 - Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... C supplied-air respirator, demand class; minimum requirements. (a) Inhalation resistance shall not... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements. 84.156 Section 84.156 Public Health PUBLIC HEALTH SERVICE...

  20. NOCTURNAL AIR-FLOW OBSTRUCTION, HISTAMINE, AND THE AUTONOMIC CENTRAL-NERVOUS-SYSTEM IN CHILDREN WITH ALLERGIC-ASTHMA

    NARCIS (Netherlands)

    VANAALDEREN, WMC; POSTMA, DS; KOETER, GH; KNOL, K

    A study was carried out to investigate whether an imbalance in the autonomic nervous system or release of histamine, or both, is responsible for the nocturnal increase in airflow obstruction in asthmatic children. The study comprised 18 children with allergic asthma,nine with (group 1) and nine

  1. Effect of mobile laminar airflow units on airborne bacterial contamination during neurosurgical procedures.

    Science.gov (United States)

    von Vogelsang, A-C; Förander, P; Arvidsson, M; Löwenhielm, P

    2018-03-24

    Surgical site infections (SSIs) after neurosurgery are potentially life-threatening and entail great costs. SSIs may occur from airborne bacteria in the operating room, and ultraclean air is desired during infection-prone cleaning procedures. Door openings and the number of persons present in the operating room affect the air quality. Mobile laminar airflow (MLAF) units, with horizontal laminar airflow, have previously been shown to reduce airborne bacterial contamination. To assess the effect of MLAF units on airborne bacterial contamination during neurosurgical procedures. In a quasi-experimental design, bacteria-carrying particles (colony-forming units: cfu) during neurosurgical procedures were measured with active air-sampling in operating rooms with conventional turbulent ventilation, and with additional MLAF units. The MLAF units were shifted between operating rooms monthly. Colony-forming unit count and bacterial species detection were conducted after incubation. Data was collected for a period of 18 months. A total of 233 samples were collected during 45 neurosurgical procedures. The use of MLAF units significantly reduced the numbers of cfu in the surgical site area (P neurosurgery to ultraclean air levels. MLAF units are valuable when the main operating room ventilation system is unable to produce ultraclean air in infection-prone clean neurosurgery. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Linear and nonlinear analysis of airflow recordings to help in sleep apnoea–hypopnoea syndrome diagnosis

    International Nuclear Information System (INIS)

    Gutiérrez-Tobal, G C; Hornero, R; Álvarez, D; Marcos, J V; Del Campo, F

    2012-01-01

    This paper focuses on the analysis of single-channel airflow (AF) signal to help in sleep apnoea–hypopnoea syndrome (SAHS) diagnosis. The respiratory rate variability (RRV) series is derived from AF by measuring time between consecutive breathings. A set of statistical, spectral and nonlinear features are extracted from both signals. Then, the forward stepwise logistic regression (FSLR) procedure is used in order to perform feature selection and classification. Three logistic regression (LR) models are obtained by applying FSLR to features from AF, RRV and both signals simultaneously. The diagnostic performance of single features and LR models is assessed and compared in terms of sensitivity, specificity, accuracy and area under the receiver-operating characteristics curve (AROC). The highest accuracy (82.43%) and AROC (0.903) are reached by the LR model derived from the combination of AF and RRV features. This result suggests that AF and RRV provide useful information to detect SAHS. (paper)

  3. SEPARATE AND COMBINED EFFECTS OF CORTICOSTEROIDS AND BRONCHODILATORS ON AIR-FLOW OBSTRUCTION AND AIRWAY HYPERRESPONSIVENESS IN ASTHMA

    NARCIS (Netherlands)

    WEMPE, JB; POSTMA, DS; BREEDERVELD, N; ALTINGHEBING, D; VANDERMARK, TW; KOETER, GH

    We have investigated separate and interactive effects of corticosteroids and bronchodilators on airflow obstruction and airway hyperresponsiveness. Twelve allergic subjects with asthma were treated in a double-blind, crossover, randomized study with budesonide, 1.6 mg daily for 3 weeks, prednisone,

  4. Persistent airflow limitation in adult-onset nonatopic asthma is associated with serologic evidence of Chlamydia pneumoniae infection

    NARCIS (Netherlands)

    ten Brinke, A.; van Dissel, J. T.; Sterk, P. J.; Zwinderman, A. H.; Rabe, K. F.; Bel, E. H.

    2001-01-01

    Persistent airflow limitation may develop in patients with asthma, particularly in adults with nonatopic (intrinsic) disease. Although the underlying mechanisms are still unknown, respiratory infections might be involved. We investigated the annual loss of lung function in relation to seropositivity

  5. Reduction of physical activity in daily life and its determinants in smokers without airflow obstruction.

    Science.gov (United States)

    Furlanetto, Karina Couto; Mantoani, Leandro Cruz; Bisca, Gianna; Morita, Andrea Akemi; Zabatiero, Juliana; Proença, Mahara; Kovelis, Demétria; Pitta, Fabio

    2014-04-01

    In smokers without airflow obstruction, detailed, objective and controlled quantification of the level of physical inactivity in daily life has never been performed. This study aimed to objectively assess the level of physical activity in daily life in adult smokers without airflow obstruction in comparison with matched non-smokers, and to investigate the determinants for daily physical activity in smokers. Sixty smokers (aged 50 (39-54) years) and 50 non-smokers (aged 48 (40-53) years) matched for gender, age, anthropometric characteristics, educational level, employment status and seasons of the year assessment period were cross-sectionally assessed regarding their daily physical activity with a step counter, besides assessment of lung function, functional exercise capacity, quality of life, anxiety, depression, self-reported comorbidities carbon monoxide level, nicotine dependence and smoking habits. When compared with non-smokers, smokers walked less in daily life (7923 ± 3558 vs 9553 ± 3637 steps/day, respectively), presented worse lung function, functional exercise capacity, quality of life, anxiety and depression. Multiple regression analyses identified functional exercise capacity, Borg fatigue, self-reported motivation/physical activity behaviour and cardiac disease as significant determinants of number of steps/day in smokers (partial r(2)  = 0.10, 0.12, 0.16 and 0.05; b = 15, -997, 1207 and -2330 steps/day, respectively; overall fit of the model R(2)  = 0.38; P smokers without airflow obstruction presented reduced level of daily physical activity. Functional exercise capacity, extended fatigue sensation, aspects of motivation/physical activity behaviour and self-reported cardiac disease are significant determinants of physical activity in daily life in smokers. © 2014 The Authors. Respirology © 2014 Asian Pacific Society of Respirology.

  6. Effects of diffuser airflow minima on occupant comfort, air mixing, and building energy use (RP-1515)

    DEFF Research Database (Denmark)

    Arens, Edward; Zhang, Hui; Hoyt, Tyler

    2015-01-01

    There is great energy-saving potential in reducing variable air volume box minimum airflow set-points to about 10% of maximum. Typical savings are on the order of 10%-30% of total HVAC energy, remarkable for an inexpensive controls set-point change that properly maintains outside air ventilation....

  7. Interactive Augmentation of Voice Quality and Reduction of Breath Airflow in the Soprano Voice.

    Science.gov (United States)

    Rothenberg, Martin; Schutte, Harm K

    2016-11-01

    In 1985, at a conference sponsored by the National Institutes of Health, Martin Rothenberg first described a form of nonlinear source-tract acoustic interaction mechanism by which some sopranos, singing in their high range, can use to reduce the total airflow, to allow holding the note longer, and simultaneously enrich the quality of the voice, without straining the voice. (M. Rothenberg, "Source-Tract Acoustic Interaction in the Soprano Voice and Implications for Vocal Efficiency," Fourth International Conference on Vocal Fold Physiology, New Haven, Connecticut, June 3-6, 1985.) In this paper, we describe additional evidence for this type of nonlinear source-tract interaction in some soprano singing and describe an analogous interaction phenomenon in communication engineering. We also present some implications for voice research and pedagogy. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  8. A liquid crystal polymer membrane MEMS sensor for flow rate and flow direction sensing applications

    International Nuclear Information System (INIS)

    Kottapalli, A G P; Tan, C W; Olfatnia, M; Miao, J M; Barbastathis, G; Triantafyllou, M

    2011-01-01

    The paper reports the design, fabrication and experimental results of a liquid crystal polymer (LCP) membrane-based pressure sensor for flow rate and flow direction sensing applications. Elaborate experimental testing results demonstrating the sensors' performance as an airflow sensor have been illustrated and validated with theory. MEMS sensors using LCP as a membrane structural material show higher sensitivity and reliability over silicon counterparts. The developed device is highly robust for harsh environment applications such as atmospheric wind flow monitoring and underwater flow sensing. A simple, low-cost and repeatable fabrication scheme has been developed employing low temperatures. The main features of the sensor developed in this work are a LCP membrane with integrated thin film gold piezoresistors deposited on it. The sensor developed demonstrates a good sensitivity of 3.695 mV (ms −1 ) −1 , large operating range (0.1 to >10 ms −1 ) and good accuracy in measuring airflow with an average error of only 3.6% full-scale in comparison with theory. Various feasible applications of the developed sensor have been demonstrated with experimental results. The sensor was tested for two other applications—in clinical diagnosis for breath rate, breath velocity monitoring, and in underwater applications for object detection by sensing near-field spatial flow pressure

  9. Experimental study of airflow characteristics of stratum ventilation in a multi-occupant room with comparison to mixing ventilation and displacement ventilation.

    Science.gov (United States)

    Cheng, Y; Lin, Z

    2015-12-01

    The motivation of this study is stimulated by a lack of knowledge about the difference of airflow characteristics between a novel air distribution method [i.e., stratum ventilation (SV)] and conventional air distribution methods [i.e., mixing ventilation (MV) and displacement ventilation (DV)]. Detailed air velocity and temperature measurements were conducted in the occupied zone of a classroom with dimensions of 8.8 m (L) × 6.1 m (W) × 2.4 m (H). Turbulence intensity and power spectrum of velocity fluctuation were calculated using the measured data. Thermal comfort and cooling efficiency were also compared. The results show that in the occupied zone, the airflow characteristics among MV, DV, and SV are different. The turbulent airflow fluctuation is enhanced in this classroom with multiple thermal manikins due to thermal buoyancy and airflow mixing effect. Thermal comfort evaluations indicate that in comparison with MV and DV, a higher supply air temperature should be adopted for SV to achieve general thermal comfort with low draft risk. Comparison of the mean air temperatures in the occupied zone reveals that SV is of highest cooling efficiency, followed by DV and then MV. This study reports the unique profiles of flow, temperature, turbulence intensity, and power spectrum of stratum ventilation, which can have a number of implications for both knowledge and understanding of the flow characteristics in a stratum-ventilated room. With respect to the former, it expounds the fundamental characteristics of this air distribution method; and with respect to the latter, it reveals the mechanism of thermal comfort and energy saving under stratum ventilation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Effect of enzymatic pretreatment on the physical quality of plantain (Musa ssp., group AAB) employing airflow reversal drying.

    Science.gov (United States)

    Rodríguez-Miranda, J; Martínez-Sánchez, C E; Hernández-Santos, B; Juárez-Barrientos, J M; Ventura-Báez, E G; Herman-Lara, E

    2018-01-01

    This work aimed to evaluate the effect of enzymatic pretreatment on the color and texture of plantain ( Musa ssp., group AAB) dried by airflow reversal drying. Plantain slices 1.0 cm thick were used. Pretreatment with two commercial enzymes, Pectinex Ultra SPL ( Aspergillus aculeatus ) and Pectinex 3XL ( Aspergillus niger ), was performed. Drying kinetics were determined with and without pretreatment at temperatures of 50, 65 and 80 °C using a fixed bed convective dryer. An air speed of 6 m/s, a bed height of 5 cm and either unidirectional flow or airflow reversal (every 15 min) were used for drying. Color and texture were analyzed, and consumer acceptance of the results of the best treatments was determined. Pretreatment with the enzyme A. niger and airflow reversal gave the best drying kinetics and showed the greatest reduction in drying time (59.0%) at 80 °C. The best hardness results were found at 80 °C with A. niger enzymatic pretreatment with both types of air flow. Brightness and hue angle showed that samples pretreated with enzymes and dried at 65 °C had a lighter yellow color compared to non-pretreated samples. Plantain samples enzymatically pretreated and dried at 65 and 80 °C were the most accepted by consumers. This kind of enzymatic pretreatment on plantain could allow the conservation of some physical properties and reduction of drying times relative to the current methodology.

  11. CITRIC-ACID COUGH THRESHOLD AND AIRWAY RESPONSIVENESS IN ASTHMATIC-PATIENTS AND SMOKERS WITH CHRONIC AIR-FLOW OBSTRUCTION

    NARCIS (Netherlands)

    AUFFARTH, B; DEMONCHY, JGR; VANDERMARK, TW; POSTMA, DS; KOETER, GH

    The relation between citric acid cough threshold and airway hyperresponsiveness was investigated in 11 non-smoking patients with allergic asthma (mean FEV1 94% predicted) and 25 non-atopic smokers with chronic airflow obstruction (mean FEV1 65% predicted). Cough threshold was determined on two

  12. High population increase rates.

    Science.gov (United States)

    1991-09-01

    In addition to its economic and ethnic difficulties, the USSR faces several pressing demographic problems, including high population increase rates in several of its constituent republics. It has now become clear that although the country's rigid centralized planning succeeded in covering the basic needs of people, it did not lead to welfare growth. Since the 1970s, the Soviet economy has remained sluggish, which as led to increase in the death and birth rates. Furthermore, the ideology that held that demography could be entirely controlled by the country's political and economic system is contradicted by current Soviet reality, which shows that religion and ethnicity also play a significant role in demographic dynamics. Currently, Soviet republics fall under 2 categories--areas with high or low natural population increase rates. Republics with low rates consist of Christian populations (Armenia, Moldavia, Georgia, Byelorussia, Russia, Lithuania, Estonia, Latvia, Ukraine), while republics with high rates are Muslim (Tadzhikistan, Uzbekistan, Turkmenistan, Kirgizia, Azerbaijan Kazakhstan). The later group has natural increase rates as high as 3.3%. Although the USSR as a whole is not considered a developing country, the later group of republics fit the description of the UNFPA's priority list. Another serious demographic issue facing the USSR is its extremely high rate of abortion. This is especially true in the republics of low birth rates, where up to 60% of all pregnancies are terminated by induced abortions. Up to 1/5 of the USSR's annual health care budget is spent on clinical abortions -- money which could be better spent on the production of contraceptives. Along with the recent political and economic changes, the USSR is now eager to deal with its demographic problems.

  13. Comparison of pulmonary function in patients with COPD, asthma-COPD overlap syndrome, and asthma with airflow limitation

    Directory of Open Access Journals (Sweden)

    Kitaguchi Y

    2016-05-01

    Full Text Available Yoshiaki Kitaguchi, Masanori Yasuo, Masayuki Hanaoka First Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, Japan Background: This study was conducted in order to investigate the differences in the respiratory physiology of patients with chronic obstructive pulmonary disease (COPD, asthma-COPD overlap syndrome (ACOS, and asthma with airflow limitation (asthma FL+. Methods: The medical records for a series of all stable patients with persistent airflow limitation due to COPD, ACOS, or asthma were retrospectively reviewed and divided into the COPD group (n=118, the ACOS group (n=32, and the asthma FL+ group (n=27. All the patients underwent chest high-resolution computed tomography (HRCT and pulmonary function tests, including respiratory impedance. Results: The low attenuation area score on chest HRCT was significantly higher in the COPD group than in the ACOS group (9.52±0.76 vs 5.09±1.16, P<0.01. The prevalence of bronchial wall thickening on chest HRCT was significantly higher in the asthma FL+ group than in the COPD group (55.6% vs 25.0%, P<0.01. In pulmonary function, forced expiratory volume in 1 second (FEV1 and peak expiratory flow rate were significantly higher in the asthma FL+ group than in the ACOS group (76.28%±2.54% predicted vs 63.43%±3.22% predicted, P<0.05 and 74.40%±3.16% predicted vs 61.08%±3.54% predicted, P<0.05, respectively. Although residual volume was significantly lower in the asthma FL+ group than in the COPD group (112.05%±4.34% predicted vs 137.38%±3.43% predicted, P<0.01 and the ACOS group (112.05%±4.34% predicted vs148.46%±6.25% predicted, P<0.01, there were no significant differences in functional residual capacity or total lung capacity. The increase in FEV1 in response to short-acting ß2-agonists was significantly greater in the ACOS group than in the COPD group (229±29 mL vs 72±10 mL, P<0.01 and the asthma FL+ group (229±29 mL vs 153±21 mL, P<0.05. Regarding

  14. The classical Starling resistor model often does not predict inspiratory airflow patterns in the human upper airway.

    Science.gov (United States)

    Owens, Robert L; Edwards, Bradley A; Sands, Scott A; Butler, James P; Eckert, Danny J; White, David P; Malhotra, Atul; Wellman, Andrew

    2014-04-15

    The upper airway is often modeled as a classical Starling resistor, featuring a constant inspiratory airflow, or plateau, over a range of downstream pressures. However, airflow tracings from clinical sleep studies often show an initial peak before the plateau. To conform to the Starling model, the initial peak must be of small magnitude or dismissed as a transient. We developed a method to simulate fast or slow inspirations through the human upper airway, to test the hypothesis that this initial peak is a transient. Eight subjects [4 obstructive sleep apnea (OSA), 4 controls] slept in an "iron lung" and wore a nasal mask connected to a continuous/bilevel positive airway pressure machine. Downstream pressure was measured using an epiglottic catheter. During non-rapid eye movement (NREM) sleep, subjects were hyperventilated to produce a central apnea, then extrathoracic pressure was decreased slowly (∼2-4 s) or abruptly (resistor model, the upper airway exhibits marked NED in some subjects.

  15. Paired maximum inspiratory and expiratory plain chest radiographs for assessment of airflow limitation in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Takashi, E-mail: tkino@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Kawayama, Tomotaka, E-mail: kawayama_tomotaka@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Imamura, Youhei, E-mail: mamura_youhei@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Sakazaki, Yuki, E-mail: sakazaki@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Hirai, Ryo, E-mail: hirai_ryou@kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Ishii, Hidenobu, E-mail: shii_hidenobu@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Suetomo, Masashi, E-mail: jin_t_f_c@yahoo.co.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Matsunaga, Kazuko, E-mail: kmatsunaga@kouhoukai.or.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Azuma, Koichi, E-mail: azuma@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Fujimoto, Kiminori, E-mail: kimichan@med.kurume-u.ac.jp [Department of Radiology, Kurume University School of Medicine, Kurume (Japan); Hoshino, Tomoaki, E-mail: hoshino@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan)

    2015-04-15

    Highlights: •It is often to use computed tomography (CT) scan for diagnosis of chronic obstructive pulmonary disease. •CT scan is more expensive and higher. •A plane chest radiography more simple and cheap. Moreover, it is useful as detection of pulmonary emphysema, but not airflow limitation. •Our study demonstrated that the maximum inspiratory and expiratory plane chest radiography technique could detect severe airflow limitations. •We believe that the technique is helpful to diagnose the patients with chronic obstructive pulmonary disease. -- Abstract: Background: The usefulness of paired maximum inspiratory and expiratory (I/E) plain chest radiography (pCR) for diagnosis of chronic obstructive pulmonary disease (COPD) is still unclear. Objectives: We examined whether measurement of the I/E ratio using paired I/E pCR could be used for detection of airflow limitation in patients with COPD. Methods: Eighty patients with COPD (GOLD stage I = 23, stage II = 32, stage III = 15, stage IV = 10) and 34 control subjects were enrolled. The I/E ratios of frontal and lateral lung areas, and lung distance between the apex and base on pCR views were analyzed quantitatively. Pulmonary function parameters were measured at the same time. Results: The I/E ratios for the frontal lung area (1.25 ± 0.01), the lateral lung area (1.29 ± 0.01), and the lung distance (1.18 ± 0.01) were significantly (p < 0.05) reduced in COPD patients compared with controls (1.31 ± 0.02 and 1.38 ± 0.02, and 1.22 ± 0.01, respectively). The I/E ratios in frontal and lateral areas, and lung distance were significantly (p < 0.05) reduced in severe (GOLD stage III) and very severe (GOLD stage IV) COPD as compared to control subjects, although the I/E ratios did not differ significantly between severe and very severe COPD. Moreover, the I/E ratios were significantly correlated with pulmonary function parameters. Conclusions: Measurement of I/E ratios on paired I/E pCR is simple and

  16. Paired maximum inspiratory and expiratory plain chest radiographs for assessment of airflow limitation in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Kinoshita, Takashi; Kawayama, Tomotaka; Imamura, Youhei; Sakazaki, Yuki; Hirai, Ryo; Ishii, Hidenobu; Suetomo, Masashi; Matsunaga, Kazuko; Azuma, Koichi; Fujimoto, Kiminori; Hoshino, Tomoaki

    2015-01-01

    Highlights: •It is often to use computed tomography (CT) scan for diagnosis of chronic obstructive pulmonary disease. •CT scan is more expensive and higher. •A plane chest radiography more simple and cheap. Moreover, it is useful as detection of pulmonary emphysema, but not airflow limitation. •Our study demonstrated that the maximum inspiratory and expiratory plane chest radiography technique could detect severe airflow limitations. •We believe that the technique is helpful to diagnose the patients with chronic obstructive pulmonary disease. -- Abstract: Background: The usefulness of paired maximum inspiratory and expiratory (I/E) plain chest radiography (pCR) for diagnosis of chronic obstructive pulmonary disease (COPD) is still unclear. Objectives: We examined whether measurement of the I/E ratio using paired I/E pCR could be used for detection of airflow limitation in patients with COPD. Methods: Eighty patients with COPD (GOLD stage I = 23, stage II = 32, stage III = 15, stage IV = 10) and 34 control subjects were enrolled. The I/E ratios of frontal and lateral lung areas, and lung distance between the apex and base on pCR views were analyzed quantitatively. Pulmonary function parameters were measured at the same time. Results: The I/E ratios for the frontal lung area (1.25 ± 0.01), the lateral lung area (1.29 ± 0.01), and the lung distance (1.18 ± 0.01) were significantly (p < 0.05) reduced in COPD patients compared with controls (1.31 ± 0.02 and 1.38 ± 0.02, and 1.22 ± 0.01, respectively). The I/E ratios in frontal and lateral areas, and lung distance were significantly (p < 0.05) reduced in severe (GOLD stage III) and very severe (GOLD stage IV) COPD as compared to control subjects, although the I/E ratios did not differ significantly between severe and very severe COPD. Moreover, the I/E ratios were significantly correlated with pulmonary function parameters. Conclusions: Measurement of I/E ratios on paired I/E pCR is simple and

  17. High Rate Digital Demodulator ASIC

    Science.gov (United States)

    Ghuman, Parminder; Sheikh, Salman; Koubek, Steve; Hoy, Scott; Gray, Andrew

    1998-01-01

    The architecture of High Rate (600 Mega-bits per second) Digital Demodulator (HRDD) ASIC capable of demodulating BPSK and QPSK modulated data is presented in this paper. The advantages of all-digital processing include increased flexibility and reliability with reduced reproduction costs. Conventional serial digital processing would require high processing rates necessitating a hardware implementation in other than CMOS technology such as Gallium Arsenide (GaAs) which has high cost and power requirements. It is more desirable to use CMOS technology with its lower power requirements and higher gate density. However, digital demodulation of high data rates in CMOS requires parallel algorithms to process the sampled data at a rate lower than the data rate. The parallel processing algorithms described here were developed jointly by NASA's Goddard Space Flight Center (GSFC) and the Jet Propulsion Laboratory (JPL). The resulting all-digital receiver has the capability to demodulate BPSK, QPSK, OQPSK, and DQPSK at data rates in excess of 300 Mega-bits per second (Mbps) per channel. This paper will provide an overview of the parallel architecture and features of the HRDR ASIC. In addition, this paper will provide an over-view of the implementation of the hardware architectures used to create flexibility over conventional high rate analog or hybrid receivers. This flexibility includes a wide range of data rates, modulation schemes, and operating environments. In conclusion it will be shown how this high rate digital demodulator can be used with an off-the-shelf A/D and a flexible analog front end, both of which are numerically computer controlled, to produce a very flexible, low cost high rate digital receiver.

  18. Overweight and obesity may lead to under-diagnosis of airflow limitation

    DEFF Research Database (Denmark)

    Çolak, Yunus; Marott, Jacob Louis; Vestbo, Jørgen

    2015-01-01

    BACKGROUND: The prevalence of obesity has increased during the last decades and varies from 10-20% in most European countries to approximately 32% in the United States. However, data on how obesity affects the presence of airflow limitation (AFL) defined as a reduced ratio between forced expiratory...... volume in 1 second (FEV1) and forced vital capacity (FVC) are scarce. METHODS: Data was derived from the third examination of the Copenhagen City Heart Study from 1991 until 1994 (n = 10,135). We examine the impact of different adiposity markers (weight, body mass index (BMI), waist circumference, waist......-diagnosis and under-treatment of COPD among individuals with overweight and obesity....

  19. Resuspension of carbon dust collected in Tore Supra and exposed to turbulent airflow: Controlled experiments and comparison with model

    Energy Technology Data Exchange (ETDEWEB)

    Peillon, S., E-mail: samuel.peillon@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES/SCA/LPMA, Saclay, Gif-sur-Yvette 91192 (France); Roynette, A. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES/SCA/LPMA, Saclay, Gif-sur-Yvette 91192 (France); Grisolia, C. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Gensdarmes, F. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES/SCA/LPMA, Saclay, Gif-sur-Yvette 91192 (France)

    2014-11-15

    Highlights: • Mobilization of dust is a key issue for the safety assessment of fusion reactors. • Carbon dust has been collected on the plasma facing components of Tore Supra. • Samples exhibit bimodal particle size distributions. • Samples have been exposed to turbulent airflows for dust resuspension studies. • A comparison with the so-called Rock’n roll resuspension model is proposed. - Abstract: This work presents the results of experiments conducted with carbon microparticles collected in the tokamak Tore Supra in order to characterize their resuspension behaviour from a stainless-steel substrate when exposed to turbulent airflow. Experiments were conducted in a wind tunnel with controlled velocity profiles and monitored environmental conditions. A consequent amount of dust has been collected in the vessel of the tokamak and a bimodal particle size distribution of samples is first demonstrated. Comparison with resuspension of alumina powders with equivalent particle size distributions under turbulent airflow is also discussed. Results for both carbon and alumina microparticles are then compared to a theoretical resuspension model. Data reveal that exposing multilayer deposits with bimodal particle size distributions to low-speed flows (i.e. 3–10 m/s) induces a significant reduction of the mobilized fractions compared to what was predicted by the model. In addition, results helped to highlight some limitations in the model to physically describe changes in the adhesive strength that can occur with a polydisperse deposit.

  20. Rain-induced subsurface airflow and Lisse effect

    Science.gov (United States)

    Guo, Haipeng; Jiao, Jiu J.; Weeks, Edwin P.

    2008-07-01

    Water-level increase after rainfall is usually indicative of rainfall recharge to groundwater. This, however, may not be true if the Lisse effect occurs. This effect represents the water-level increase in a well driven by airflow induced by an advancing wetting front during highly intensive rains. The rainwater, which may behave like a low-permeability lid, seals the ground surface so that the air pressure beneath the wetting front is increased because of air compression due to downward movement of the wetting front. A rapid and substantial rise of the water level in the well screened below water table, which bears no relationship to groundwater recharge, can be induced when various factors such as soil properties and the rain-runoff condition combine favorably. A transient, three-dimensional and variably saturated flow model was employed to study the air and groundwater flows in the soil under rain conditions. The objectives of this paper are two-fold: to evaluate the reliability of the theory of the Lisse effect presented by Weeks to predict its magnitude in modeled situations that mimic the physical complexity of real aquifers, and to conduct parametric studies on the sensitivity of the water-level rise in the well to soil properties and the rain event. The simulation results reveal that the magnitude of the Lisse effect increases with the ponding depth. Soil permeability plays a key role in generating the Lisse effect. The water-level rise in the well is delayed relative to the air-pressure rise in the unsaturated zone when the soil permeability is low, and the maximum water-level rise is less than the maximum air pressure induced by rain infiltration. The simulation also explores the sensitivity of the Lisse effect to the van Genuchten parameters and the water table depth.

  1. Rain‐induced subsurface airflow and Lisse effect

    Science.gov (United States)

    Guo, Haipeng; Jiao, Jiu J.; Weeks, Edwin P.

    2008-01-01

    Water‐level increase after rainfall is usually indicative of rainfall recharge to groundwater. This, however, may not be true if the Lisse effect occurs. This effect represents the water‐level increase in a well driven by airflow induced by an advancing wetting front during highly intensive rains. The rainwater, which may behave like a low‐permeability lid, seals the ground surface so that the air pressure beneath the wetting front is increased because of air compression due to downward movement of the wetting front. A rapid and substantial rise of the water level in the well screened below water table, which bears no relationship to groundwater recharge, can be induced when various factors such as soil properties and the rain‐runoff condition combine favorably. A transient, three‐dimensional and variably saturated flow model was employed to study the air and groundwater flows in the soil under rain conditions. The objectives of this paper are two‐fold: to evaluate the reliability of the theory of the Lisse effect presented by Weeks to predict its magnitude in modeled situations that mimic the physical complexity of real aquifers, and to conduct parametric studies on the sensitivity of the water‐level rise in the well to soil properties and the rain event. The simulation results reveal that the magnitude of the Lisse effect increases with the ponding depth. Soil permeability plays a key role in generating the Lisse effect. The water‐level rise in the well is delayed relative to the air‐pressure rise in the unsaturated zone when the soil permeability is low, and the maximum water‐level rise is less than the maximum air pressure induced by rain infiltration. The simulation also explores the sensitivity of the Lisse effect to the van Genuchten parameters and the water table depth.

  2. Frequency of self-reported COPD exacerbation and airflow obstruction in five Latin American cities: the Proyecto Latinoamericano de Investigacion en Obstruccion Pulmonar (PLATINO) study.

    Science.gov (United States)

    Montes de Oca, Maria; Tálamo, Carlos; Halbert, Ronald J; Perez-Padilla, Rogelio; Lopez, Maria Victorina; Muiño, Adriana; Jardim, José Roberto B; Valdivia, Gonzalo; Pertuzé, Julio; Moreno, Dolores; Menezes, Ana Maria B

    2009-07-01

    Recurrent exacerbations are common in COPD patients. Limited information exists regarding exacerbation frequency in COPD patients from epidemiologic studies. We examined the frequency of self-reported exacerbations and the factors influencing exacerbation frequency among COPD patients in a population-based study conducted in Latin America. We used a post-bronchodilator FEV(1)/FVC ratio of < 0.70 to define COPD. Exacerbation was self-reported and defined by symptoms (deterioration of breathing symptoms that affected usual daily activities or caused missed work). Spirometry was performed in 5,314 subjects. There were 759 subjects with airflow limitation; of these, 18.2% reported ever having had an exacerbation, 7.9% reported having an exacerbation, and 6.2% reported having an exacerbation requiring at least a doctor visit within the past year. The proportion of individuals with an exacerbation significantly increased by Global Initiative for Chronic Obstructive Lung Disease (GOLD) stages, from 4.2% in stage 1 to 28.9% in stages 3 and 4. The self-reported exacerbation rate was 0.58 exacerbations per year. The rate of exacerbations requiring at least a doctor visit and length of stay in hospital due to exacerbations also increased as COPD severity progressed. The factors associated with having an exacerbation in the past year were dyspnea, prior asthma diagnosis, receiving any respiratory therapy, and disease severity of GOLD stages 3 and 4. The proportion of individuals with airflow limitation and self-reported exacerbation increases as the disease severity progresses. Dyspnea, prior asthma diagnosis, receiving any respiratory therapy, and more severe obstruction were significantly associated with having an exacerbation in the past year.

  3. The performance and subjective responses of call-center operators with new and used supply air filters at two outdoor air supply rates

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Wyon, David; Fanger, Povl Ole

    2004-01-01

    A 2X2 replicated field intervention experiment was conducted in a call-center providing a telephone directory service: outdoor air supply rate was adjusted to be 8% of the total airflow of 430 l/s (3.5/h)and the supply air filters were either new or had been in place for 6 months. One of these in......A 2X2 replicated field intervention experiment was conducted in a call-center providing a telephone directory service: outdoor air supply rate was adjusted to be 8% of the total airflow of 430 l/s (3.5/h)and the supply air filters were either new or had been in place for 6 months. One...

  4. Influence of input data on airflow network accuracy in residential buildings with natural wind- and stack-driven ventilation

    Institute of Scientific and Technical Information of China (English)

    Krzysztof Arendt; Marek Krzaczek; Jacek Tejchman

    2017-01-01

    The airflow network (AFN) modeling approach provides an attractive balance between the accuracy and computational demand for naturally ventilated buildings. Its accuracy depends on input parameters such as wind pressure and opening discharge coefficients. In most cases, these parameters are obtained from secondary sources which are solely representative for very simplified buildings, i.e. for buildings without facade details. Although studies comparing wind pressure coefficients or discharge coefficients from different sources exist, the knowledge regarding the effect of input data on AFN is still poor. In this paper, the influence of wind pressure data on the accuracy of a coupled AFN-BES model for a real building with natural wind- and stack-driven ventilation was analyzed. The results of 8 computation cases with different wind pressure data from secondary sources were compared with the measured data. Both the indoor temperatures and the airflow were taken into account. The outcomes indicated that the source of wind pressure data had a significant influence on the model performance.

  5. The Evaporation of Liquid Droplets in Highly Turbulent Gas Streams

    National Research Council Canada - National Science Library

    Gould, Richard

    1998-01-01

    Single acetone and heptane droplets were suspended from a hypodermic needle in turbulent airflow, and the Nusselt number was obtained from direct measurements of the droplet diameter and evaporation rate...

  6. A modeling study of the effect of gravity on airflow distribution and particle deposition in the lung.

    Science.gov (United States)

    Asgharian, Bahman; Price, Owen; Oberdörster, Gunter

    2006-06-01

    Inhalation of particles generated as a result of thermal degradation from fire or smoke, as may occur on spacecraft, is of major health concern to space-faring countries. Knowledge of lung airflow and particle transport under different gravity environments is required to addresses this concern by providing information on particle deposition. Gravity affects deposition of particles in the lung in two ways. First, the airflow distribution among airways is changed in different gravity environments. Second, particle losses by sedimentation are enhanced with increasing gravity. In this study, a model of airflow distribution in the lung that accounts for the influence of gravity was used for a mathematical description of particle deposition in the human lung to calculate lobar, regional, and local deposition of particles in different gravity environments. The lung geometry used in the mathematical model contained five lobes that allowed the assessment of lobar ventilation distribution and variation of particle deposition. At zero gravity, it was predicted that all lobes of the lung expanded and contracted uniformly, independent of body position. Increased gravity in the upright position increased the expansion of the upper lobes and decreased expansion of the lower lobes. Despite a slight increase in predicted deposition of ultrafine particles in the upper lobes with decreasing gravity, deposition of ultrafine particles was generally predicted to be unaffected by gravity. Increased gravity increased predicted deposition of fine and coarse particles in the tracheobronchial region, but that led to a reduction or even elimination of deposition in the alveolar region for coarse particles. The results from this study show that existing mathematical models of particle deposition at 1 G can be extended to different gravity environments by simply correcting for a gravity constant. Controlled studies in astronauts on future space missions are needed to validate these predictions.

  7. Relationship of airway dimensions with airflow limitation or lung volumes in chronic obstructive pulmonary disease (COPD

    Directory of Open Access Journals (Sweden)

    Masaru Hasegawa

    2006-12-01

    Full Text Available We have recently developed new software to obtain longitudinal images and accurate short axis images of airways with an inner diameter > 2 mm located anywhere in the lung, using curved multiplanar reconstruction. Using this software, we demonstrated in patients with COPD that FEV1 (%predicted was highly correlated with airway dimensions and the correlation coefficients improved as the airway became smaller in size (3. In this study, our aims are to further confirm the significant relationship between airway dimensions and airflow limitation in larger number of subjects, and to examine the relationship of airway dimensions with lung volumes in 95 patients with COPD (stage 0, 10; stage I, 23; stage II, 35; stage III, 24; stage IV, 3. We analyzed the airway dimensions from the 3rd to the 6th generations of the apical bronchus (B1 of the right upper lobe and the anterior basal bronchus (B8 of the right lower lobe. Lung volumes were measured by the helium closed circuit method. Both airway luminal area (Ai and wall area percent (WA% of all the generations, except a few, from the two bronchi were significantly correlated with RV and RV/TLC, but not with TLC or FRC. More importantly, the correlation coefficients (r between airway dimensions and RV/TLC improved as the airways became smaller in size from the 3rd to 6th generations in both bronchi (r = –0.483, –0482, –0.553, –0.624 for Ai of B8; r = 0.316, 0.380, 0.499, 0.551 for WA% of B8. These findings provide further evidence that distal (small airways rather than proximal (large airways are the determinants for airflow limitation in COPD.

  8. Mobile ultra-clean unidirectional airflow screen reduces air contamination in a simulated setting for intra-vitreal injection.

    Science.gov (United States)

    Lapid-Gortzak, Ruth; Traversari, Roberto; van der Linden, Jan Willem; Lesnik Oberstein, Sarit Y; Lapid, Oren; Schlingemann, Reinier O

    2017-02-01

    The aim of this study is to determine whether the use of a mobile ultra-clean laminar airflow screen reduces the air-borne particle counts in the setting of a simulated procedure of an intra-vitreal injection. A mobile ultra-clean unidirectional airflow (UDF) screen was tested in a simulated procedure for intra-vitreal injections in a treatment room without mechanical ventilation. One UDF was passed over the instrument tray and the surgical area. The concentration of particles was measured in the background, over the instrument table, and next to the ocular area. The degree of protection was calculated at the instrument table and at the surgical site. Use of the UDF mobile screen reduced the mean particle concentration (particles > 0.3 microns) on the instrument table by a factor of at least 100.000 (p air contamination. Mobile UDF screen reduces the mean particle concentration substantially. The mobile UDF screen may therefore allow for a safer procedural environment for ambulatory care procedures such as intra-vitreal injections in treatment rooms.

  9. Morphological measurements in computed tomography correlate with airflow obstruction in chronic obstructive pulmonary disease : systematic review and meta-analysis

    NARCIS (Netherlands)

    Xie, X.Q.; de Jong, P.A.; Oudkerk, M.; Wang, Y.; ten Hacken, N.H.T.; Miao, J.T.; Zhang, GuiXiang; de Bock, G.H.; Vliegenthart, R.

    2012-01-01

    To determine the correlation between CT measurements of emphysema or peripheral airways and airflow obstruction in chronic obstructive pulmonary disease (COPD). PubMed, Embase and Web of Knowledge were searched from 1976 to 2011. Two reviewers independently screened 1,763 citations to identify

  10. A review of air exchange rate models for air pollution exposure assessments.

    Science.gov (United States)

    Breen, Michael S; Schultz, Bradley D; Sohn, Michael D; Long, Thomas; Langstaff, John; Williams, Ronald; Isaacs, Kristin; Meng, Qing Yu; Stallings, Casson; Smith, Luther

    2014-11-01

    A critical aspect of air pollution exposure assessments is estimation of the air exchange rate (AER) for various buildings where people spend their time. The AER, which is the rate of exchange of indoor air with outdoor air, is an important determinant for entry of outdoor air pollutants and for removal of indoor-emitted air pollutants. This paper presents an overview and critical analysis of the scientific literature on empirical and physically based AER models for residential and commercial buildings; the models highlighted here are feasible for exposure assessments as extensive inputs are not required. Models are included for the three types of airflows that can occur across building envelopes: leakage, natural ventilation, and mechanical ventilation. Guidance is provided to select the preferable AER model based on available data, desired temporal resolution, types of airflows, and types of buildings included in the exposure assessment. For exposure assessments with some limited building leakage or AER measurements, strategies are described to reduce AER model uncertainty. This review will facilitate the selection of AER models in support of air pollution exposure assessments.

  11. ``Magical'' fluid pathways: inspired airflow corridors for optimal drug delivery to human sinuses

    Science.gov (United States)

    Basu, Saikat; Farzal, Zainab; Kimbell, Julia S.

    2017-11-01

    Topical delivery methods like nasal sprays are an important therapeutic component for sinusitis (inflammation and clogging of the paranasal sinuses). The sinuses are air-filled sacs, identified as: maxillaries (under the eyes and deep to cheeks bilaterally; largest in volume), frontals (above and medial to the eyes, behind forehead area), ethmoids (between the eyes, inferior to the frontal sinuses), and sphenoids (superior and posterior to ethmoids). We develop anatomic CT-based 3D reconstructions of the human nasal cavity for multiple subjects. Through CFD simulations on Fluent for measured breathing rates, we track inspiratory airflow in all the models and the corresponding sprayed drug transport (for a commercially available sprayer, with experimentally tested particle size distributions). The protocol is implemented for a wide array of spray release points. We make the striking observation that the same release points in each subject provide better particle deposition in all the sinuses, despite the sinuses being located at different portions of the nasal cavity. This leads to the conjecture that the complicated anatomy-based flow physics artifacts in the nasal canal generate certain ``magical'' streamlines, providing passage for improved drug transport to all sinus targets. Supported by NIH Grant R01 HL122154.

  12. Simulation model of a twin-tail, high performance airplane

    Science.gov (United States)

    Buttrill, Carey S.; Arbuckle, P. Douglas; Hoffler, Keith D.

    1992-01-01

    The mathematical model and associated computer program to simulate a twin-tailed high performance fighter airplane (McDonnell Douglas F/A-18) are described. The simulation program is written in the Advanced Continuous Simulation Language. The simulation math model includes the nonlinear six degree-of-freedom rigid-body equations, an engine model, sensors, and first order actuators with rate and position limiting. A simplified form of the F/A-18 digital control laws (version 8.3.3) are implemented. The simulated control law includes only inner loop augmentation in the up and away flight mode. The aerodynamic forces and moments are calculated from a wind-tunnel-derived database using table look-ups with linear interpolation. The aerodynamic database has an angle-of-attack range of -10 to +90 and a sideslip range of -20 to +20 degrees. The effects of elastic deformation are incorporated in a quasi-static-elastic manner. Elastic degrees of freedom are not actively simulated. In the engine model, the throttle-commanded steady-state thrust level and the dynamic response characteristics of the engine are based on airflow rate as determined from a table look-up. Afterburner dynamics are switched in at a threshold based on the engine airflow and commanded thrust.

  13. Numerical simulations of island-scale airflow over Maui and the Maui vortex under summer trade wind conditions

    Science.gov (United States)

    DaNa L. Carlis; Yi-Leng Chen; Vernon R. Morris

    2010-01-01

    The fifth-generation Pennsylvania State University–NCAR Mesoscale Model (MM5) coupled with the Noah land surface model (LSM) is employed to simulate island-scale airflow and circulations over Maui County, Hawaii, under summer trade wind conditions, during July–August 2005. The model forecasts are validated by surface observations with good agreement.

  14. Details of regional particle deposition and airflow structures in a realistic model of human tracheobronchial airways: two-phase flow simulation.

    Science.gov (United States)

    Rahimi-Gorji, Mohammad; Gorji, Tahereh B; Gorji-Bandpy, Mofid

    2016-07-01

    In the present investigation, detailed two-phase flow modeling of airflow, transport and deposition of micro-particles (1-10µm) in a realistic tracheobronchial airway geometry based on CT scan images under various breathing conditions (i.e. 10-60l/min) was considered. Lagrangian particle tracking has been used to investigate the particle deposition patterns in a model comprising mouth up to generation G6 of tracheobronchial airways. The results demonstrated that during all breathing patterns, the maximum velocity change occurred in the narrow throat region (Larynx). Due to implementing a realistic geometry for simulations, many irregularities and bending deflections exist in the airways model. Thereby, at higher inhalation rates, these areas are prone to vortical effects which tend to entrap the inhaled particles. According to the results, deposition fraction has a direct relationship with particle aerodynamic diameter (for dp=1-10µm). Enhancing inhalation flow rate and particle size will largely increase the inertial force and consequently, more particle deposition is evident suggesting that inertial impaction is the dominant deposition mechanism in tracheobronchial airways. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Circulating activated innate lymphoid cells and mucosal-associated invariant T cells are associated with airflow limitation in patients with asthma

    Directory of Open Access Journals (Sweden)

    Ayako Ishimori

    2017-04-01

    Conclusions: For the first time, our data showed that activated NK cells, ILC1s, ILC2s, ILC3s, and MAIT cells were positively correlated with each other and may be associated with airflow limitation in patients with asthma.

  16. Impact of airborne particle size, acoustic airflow and breathing pattern on delivery of nebulized antibiotic into the maxillary sinuses using a realistic human nasal replica.

    Science.gov (United States)

    Leclerc, Lara; Pourchez, Jérémie; Aubert, Gérald; Leguellec, Sandrine; Vecellio, Laurent; Cottier, Michèle; Durand, Marc

    2014-09-01

    Improvement of clinical outcome in patients with sinuses disorders involves targeting delivery of nebulized drug into the maxillary sinuses. We investigated the impact of nebulization conditions (with and without 100 Hz acoustic airflow), particle size (9.9 μm, 2.8 μm, 550 nm and 230 nm) and breathing pattern (nasal vs. no nasal breathing) on enhancement of aerosol delivery into the sinuses using a realistic nasal replica developed by our team. After segmentation of the airways by means of high-resolution computed tomography scans, a well-characterized nasal replica was created using a rapid prototyping technology. A total of 168 intrasinus aerosol depositions were performed with changes of aerosol particle size and breathing patterns under different nebulization conditions using gentamicin as a marker. The results demonstrate that the fraction of aerosol deposited in the maxillary sinuses is enhanced by use of submicrometric aerosols, e.g. 8.155 ± 1.476 mg/L of gentamicin in the left maxillary sinus for the 2.8 μm particles vs. 2.056 ± 0.0474 for the 550 nm particles. Utilization of 100-Hz acoustic airflow nebulization also produced a 2- to 3-fold increase in drug deposition in the maxillary sinuses (e.g. 8.155 ± 1.476 vs. 3.990 ± 1.690 for the 2.8 μm particles). Our study clearly shows that optimum deposition was achieved using submicrometric particles and 100-Hz acoustic airflow nebulization with no nasal breathing. It is hoped that our new respiratory nasal replica will greatly facilitate the development of more effective delivery systems in the future.

  17. A study on new method of noninvasive esophageal venous pressure measurement based on the airflow and laser detection technology.

    Science.gov (United States)

    Hu, Chenghuan; Huang, Feizhou; Zhang, Rui; Zhu, Shaihong; Nie, Wanpin; Liu, Xunyang; Liu, Yinglong; Li, Peng

    2015-01-01

    Using optics combined with automatic control and computer real-time image detection technology, a novel noninvasive method of noncontact pressure manometry was developed based on the airflow and laser detection technology in this study. The new esophageal venous pressure measurement system was tested in-vitro experiments. A stable and adjustable pulse stream was produced from a self-developed pump and a laser emitting apparatus could generate optical signals which can be captured by image acquisition and analysis system program. A synchronization system simultaneous measured the changes of air pressure and the deformation of the vein wall to capture the vascular deformation while simultaneously record the current pressure value. The results of this study indicated that the pressure values tested by the new method have good correlation with the actual pressure value in animal experiments. The new method of noninvasive pressure measurement based on the airflow and laser detection technology is accurate, feasible, repeatable and has a good application prospects.

  18. Optimized damper control of pressure and airflow in ventilation systems

    DEFF Research Database (Denmark)

    Koulani, Chrysanthi Sofia; Hviid, Christian Anker; Terkildsen, Søren

    2014-01-01

    Conventional control strategies in variable air volume (VAV) ventilation systems do not take fully into advantage the potential energy savings since the system operation is based on maintaining a constant static pressure (CSP) set point in the main duct irrespective of the actual pressure demand...... by using the Simulink programming tool which is addon software to MATLAB mathematical programming language. A model of a VAV ventilation system was created in Simulink based on the International Building Physics Toolbox (IBPT); the IBPT thermal zone was remodelled in order to calculate dynamically...... the airflow demand according to the zone air temperature. The performance of the Simulink model was evaluated based on the experimental setup of the ventilation system. The SPR control method established stable system operation and was proven efficient to maintain comfortable space conditions while reducing...

  19. Understanding High Rate Behavior Through Low Rate Analog

    Science.gov (United States)

    2014-04-28

    challenges in high rate character- isation of polymers. The most important is that, owing to their low stress wavespeed, the structural response of...box’ tool, to provide supporting date for the rate dependent mechanical character- isation . Experiments were performed on a TA instruments Q800

  20. Reuter Centrifugal Air Sampler: Measurement of Effective Airflow Rate and Collection Efficiency

    OpenAIRE

    Macher, J. M.; First, M. W.

    1983-01-01

    Incorrect calculation of effective air sampling rate and disregard of differences in collection efficiency among samplers can lead to false conclusions about the usefulness of samplers for measuring concentrations of airborne microorganisms.

  1. High burn rate solid composite propellants

    Science.gov (United States)

    Manship, Timothy D.

    High burn rate propellants help maintain high levels of thrust without requiring complex, high surface area grain geometries. Utilizing high burn rate propellants allows for simplified grain geometries that not only make production of the grains easier, but the simplified grains tend to have better mechanical strength, which is important in missiles undergoing high-g accelerations. Additionally, high burn rate propellants allow for a higher volumetric loading which reduces the overall missile's size and weight. The purpose of this study is to present methods of achieving a high burn rate propellant and to develop a composite propellant formulation that burns at 1.5 inches per second at 1000 psia. In this study, several means of achieving a high burn rate propellant were presented. In addition, several candidate approaches were evaluated using the Kepner-Tregoe method with hydroxyl terminated polybutadiene (HTPB)-based propellants using burn rate modifiers and dicyclopentadiene (DCPD)-based propellants being selected for further evaluation. Propellants with varying levels of nano-aluminum, nano-iron oxide, FeBTA, and overall solids loading were produced using the HTPB binder and evaluated in order to determine the effect the various ingredients have on the burn rate and to find a formulation that provides the burn rate desired. Experiments were conducted to compare the burn rates of propellants using the binders HTPB and DCPD. The DCPD formulation matched that of the baseline HTPB mix. Finally, GAP-plasticized DCPD gumstock dogbones were attempted to be made for mechanical evaluation. Results from the study show that nano-additives have a substantial effect on propellant burn rate with nano-iron oxide having the largest influence. Of the formulations tested, the highest burn rate was a 84% solids loading mix using nano-aluminum nano-iron oxide, and ammonium perchlorate in a 3:1(20 micron: 200 micron) ratio which achieved a burn rate of 1.2 inches per second at 1000

  2. Investigation of Airflow Patterns in a New Design of Wind Tower with a Wetted Surface

    Directory of Open Access Journals (Sweden)

    Madjid Soltani

    2018-04-01

    Full Text Available Passive cooling systems, such as wind towers, can help to reduce energy consumption in buildings and at the same time reduce greenhouse gas (GHG emissions. Wind towers can naturally ventilate buildings and also can create enhanced thermal comfort for occupants during the warm months. This study proposes a modern wind tower design with a moistened pad. The new design includes a fixed column, a rotating and movable head, an air opening with a screen, and two windows at the end of the column. The wind tower can be installed on roof-tops to take advantage of ambient airflow. The wind tower’s head can be controlled manually or automatically to capture optimum wind velocity based on desired thermal condition. To maximize its performance, a small pump was considered to circulate and spray water on an evaporative cooling pad. A computational fluid dynamics (CFD simulation of airflow around and inside the proposed wind tower is conducted to analyze the ventilation performance of this new design of wind tower. Thereby, the velocity, total pressure, and pressure coefficient distributions around and within the wind tower for different wind velocities are examined. The simulation results illustrate that the new wind tower design with a moistened pad can be a reasonable solution to improve naturally the thermal comfort of buildings in hot and dry climates.

  3. Chronic air-flow limitation does not increase respiratory epithelial permeability assessed by aerosolized solute, but smoking does

    International Nuclear Information System (INIS)

    Huchon, G.J.; Russell, J.A.; Barritault, L.G.; Lipavsky, A.; Murray, J.F.

    1984-01-01

    To determine the separate influences of smoking and severe air-flow limitation on aerosol deposition and respiratory epithelial permeability, we studied 26 normal nonsmokers, 12 smokers without airway obstruction, 12 nonsmokers with chronic obstructive pulmonary disease (COPD), and 11 smokers with COPD. We aerosolized 99mTc-labeled diethylene triamine pentaacetic acid to particles approximately 1 micron activity median aerodynamic diameter. Levels of radioactivity were plotted semilogarithmically against time to calculate clearance as percent per minute. The distribution of radioactivity was homogeneous in control subjects and in smokers, but patchy in both groups with COPD. No difference was found between clearances of the control group (1.18 +/- 0.31% min-1), and nonsmoker COPD group (1.37 +/- 0.82% min-1), whereas values in smokers without COPD (4.00 +/- 1.70% min-1) and smokers with COPD (3.62 +/- 2.88% min-1) were significantly greater than in both nonsmoking groups. We conclude that (1) small particles appear to deposit peripherally, even with severe COPD; (2) respiratory epithelial permeability is normal in nonsmokers with COPD; (3) smoking increases permeability by a mechanism unrelated to air-flow limitation

  4. Numerical analysis of airflow cyclic variation during intake and compression process in a 4-stroke engine

    International Nuclear Information System (INIS)

    Fadzi, M.A.; Zakaria, S.; Yusoff, M.Z; Yusaf, T.

    2004-01-01

    A degree of turbulence is one of the main factors that used to optimize the combustion efficiency, the specific fuel consumption and emissions in automotive engines. A 3D numerical study was prepared to evaluate how the complex geometry of a dome-roof and a pent-roof engine influences the flow field. A 4-stroke, 100cc SI motorcycle engine was used as the model. Engines operating at 1000 rpm and fixed atmospheric conditions were simulated using a commercial computational fluid dynamics (CFD) solver Star CD for cold flow simulations for both induction and compression stroke. Post processing stage was used to observe the cyclic airflows. The simulated results were utilized to compare aerodynamic characteristic in term of swirl and tumble motion. Variations of airflow in the cylinder were viewed through different specific geometry of both combustion chambers. Numerical results show that higher swirl was generated in the dome-roof shape. Results from Star CD simulations were translated into numerical data to compare the value of swirl ratio for both pent-roof and dome-roof engine. Remarkable insights are gained into how the chamber geometry can influence homogeneity of gas mixtures and indirectly affect the efficiency of an engine. (author)

  5. Fixed (slow moving) bed updraft gasification of agricultural residues

    Energy Technology Data Exchange (ETDEWEB)

    Vigouroux, Rolando Zanzi [Royal Institute of Technology (KTH), Stockholm (Sweden). Dept. of Chemical Engineering and Technology], E-mail: rolando@ket.kth.se; Escalona, Ronoldy Faxas [University of Oriente, Santiago de Cuba (Cuba). Fac. of Mechanical Engineering], E-mail: faxas@fim.uo.edu.cu

    2009-07-01

    Birch, in form of pellets has been gasified in updraft fixed-bed gasifier using air as oxidation agent. The main objectives were to study the effect of the treatment conditions on the distribution of the products and the composition of product gas. The influence of the air flow rates on the composition of the producer gas has been studied. The amount of the biomass used in the experiments was varied between 1 and 4 kg and the flow rate of the air was varied from 1.1 to 2.6 m3/h. Increased airflow rates favored higher temperatures. Excessively high airflow rates resulted in fast consumption of the biomass and it also favored combustion over gasification and thus formation of lower amounts of combustible products. High airflow rates caused also higher yields of tars, due to the shorter residence time of the tar-rich gas in the gasifier and thus unfavorable conditions for tar cracking. (author)

  6. The influence of wind speed on airflow and fine particle transport within different building layouts of an industrial city.

    Science.gov (United States)

    Mei, Dan; Wen, Meng; Xu, Xuemei; Zhu, Yuzheng; Xing, Futang

    2018-04-20

    In atmospheric environment, the layout difference of urban buildings has a powerful influence on accelerating or inhibiting the dispersion of particle matters (PM). In industrial cities, buildings of variable heights can obstruct the diffusion of PM from industrial stacks. In this study, PM dispersed within building groups was simulated by Reynolds-averaged Navier-Stokes equations coupled Lagrangian approach. Four typical street building arrangements were used: (a) a low-rise building block with Height/base H/b = 1 (b = 20 m); (b) step-up building layout (H/b = 1, 2, 3, 4); (c) step-down building layout (H/b = 4, 3, 2, 1); (d) high-rise building block (H/b = 5). Profiles of stream functions and turbulence intensity were used to examine the effect of various building layouts on atmospheric airflow. Here, concepts of particle suspension fraction and concentration distribution were used to evaluate the effect of wind speed on fine particle transport. These parameters showed that step-up building layouts accelerated top airflow and diffused more particles into street canyons, likely having adverse effects on resident health. In renewal old industry areas, the step-down building arrangement which can hinder PM dispersion from high-level stacks should be constructed preferentially. High turbulent intensity results in formation of a strong vortex that hinders particles into the street canyons. It is found that an increase in wind speed enhanced particle transport and reduced local particle concentrations, however, it did not affect the relative location of high particle concentration zones, which are related to building height and layout. This study has demonstrated the height variation and layout of urban architecture affect the local concentration distribution of particulate matter (PM) in the atmosphere and for the first time that wind velocity has particular effects on PM transport in various building groups. The findings may have general implications in optimization

  7. Influence of shock waves from plasma actuators on transonic and supersonic airflow

    Science.gov (United States)

    Mursenkova, I. V.; Znamenskaya, I. A.; Lutsky, A. E.

    2018-03-01

    This paper presents experimental and numerical investigations of high-current sliding surface discharges of nanosecond duration and their effect on high-speed flow as plasma actuators in a shock tube. This study deals with the effectiveness of a sliding surface discharge at low and medium air pressure. Results cover the electrical characteristics of the discharge and optical visualization of the discharge and high-speed post-discharge flow. A sliding surface discharge is first studied in quiescent air conditions and then in high-speed flow, being initiated in the boundary layer at a transverse flow velocity of 50-950 m s-1 behind a flat shock wave in air of density 0.04-0.45 kg m-3. The discharge is powered by a pulse voltage of 25-30 kV and the electric current is ~0.5 kA. Shadow imaging and particle image velocimetry (PIV) are used to measure the flow field parameters after the pulse surface discharge. Shadow imaging reveals shock waves originating from the channels of the discharge configurations. PIV is used to measure the velocity field resulting from the discharge in quiescent air and to determine the homogeneity of energy release along the sliding discharge channel. Semicylindrical shock waves from the channels of the sliding discharge have an initial velocity of more than 600 m s-1. The shock-wave configuration floats in the flow along the streamlined surface. Numerical simulation based on the equations of hydrodynamics matched with the experiment showed that 25%-50% of the discharge energy is instantly transformed into heat energy in a high-speed airflow, leading to the formation of shock waves. This energy is comparable to the flow enthalpy and can result in significant modification of the boundary layer and the entire flow.

  8. Assessment of operating room airflow using air particle counts and direct observation of door openings.

    Science.gov (United States)

    Teter, Jonathan; Guajardo, Isabella; Al-Rammah, Tamrah; Rosson, Gedge; Perl, Trish M; Manahan, Michele

    2017-05-01

    The role of the operating room (OR) environment has been thought to contribute to surgical site infection rates. The quality of OR air, disruption of airflow, and other factors may increase contamination risks. We measured air particulate counts (APCs) to determine if they increased in relation to traffic, door opening, and other common activities. During 1 week, we recorded APCs in 5-minute intervals and movement of health care workers. Trained observers recorded information about traffic, door openings, job title of the opener, and the reason for opening. At least 1 OR door was open during 47% of all readings. There were 13.4 door openings per hour during cases. Door opening rates ranged from 0.19-0.28 per minute. During this time, a total of 660 air measurements were obtained. The mean APCs were 9,238 particles (95% confidence interval [CI], 5,494- 12,982) at baseline and 14,292 particles (95% CI, 12,382-16,201) during surgery. Overall APCs increased 13% when either door was opened (P opening. We observed numerous instances of verbal communication and equipment movement. Improving efficiency of communication and equipment can aid in reduction of traffic. Further study is needed to examine links between microbiologic sampling, outcome data, and particulate matter to enable study of risk factors and effects of personnel movement. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  9. Experimental study of the inverse diffusion flame using high repetition rate OH/acetone PLIF and PIV

    KAUST Repository

    Elbaz, Ayman M.; Roberts, William L.

    2015-01-01

    Most previous work on inverse diffusion flames (IDFs) has focused on laminar IDF emissions and the soot formation characteristics. Here, we investigate the characteristics and structure of methane IDFs using high speed planar laser-induced fluorescence (PLIF) images of OH, particle image velocimetry (PIV), and acetone PLIF imaging for non-reacting cases. First, the flame appearance was investigated with fixed methane loading (mass flux) but with varying airflow rates, yielding a central air jet Reynolds number (Re) of 1,000 to 6,000 (when blow-off occurs). Next, it was investigated a fixed central air jet Re of 4500, but with varied methane mass flux such that the global equivalence ratio spanned 0.5 to 4. It was observed that at Re smaller than 2000, the inner air jet promotes the establishment of an inverse diffusion flame surrounded by a normal diffusion flame. However, when the Re was increased to 2500, two distinct zones became apparent in the flame, a lower entrainment zone and an upper mixing and combustion zone. 10 kHz OH-PLIF images, and 2D PIV allow the identification of the fate and spatial flame structure. Many flame features were identified and further analyzed using simple but effective image processing methods, where three types of structure in all the flames investigated here: flame holes or breaks; closures; and growing kernels. Insights about the rate of evolution of these features, the dynamics of local extinction, and the sequence of events that lead to re-ignition are reported here. In the lower entrainment zone, the occurrence of the flame break events is counterbalanced by closure events, and the edge propagation appears to control the rate at which the flame holes and closures propagate. The rate of propagation of holes was found to be statistically faster than the rate of closure. As the flames approach blow-off, flame kernels become the main mechanism for flame re-ignition further downstream. The simultaneous OH-PLIF/Stereo PIV

  10. Experimental study of the inverse diffusion flame using high repetition rate OH/acetone PLIF and PIV

    KAUST Repository

    Elbaz, Ayman M.

    2015-10-29

    Most previous work on inverse diffusion flames (IDFs) has focused on laminar IDF emissions and the soot formation characteristics. Here, we investigate the characteristics and structure of methane IDFs using high speed planar laser-induced fluorescence (PLIF) images of OH, particle image velocimetry (PIV), and acetone PLIF imaging for non-reacting cases. First, the flame appearance was investigated with fixed methane loading (mass flux) but with varying airflow rates, yielding a central air jet Reynolds number (Re) of 1,000 to 6,000 (when blow-off occurs). Next, it was investigated a fixed central air jet Re of 4500, but with varied methane mass flux such that the global equivalence ratio spanned 0.5 to 4. It was observed that at Re smaller than 2000, the inner air jet promotes the establishment of an inverse diffusion flame surrounded by a normal diffusion flame. However, when the Re was increased to 2500, two distinct zones became apparent in the flame, a lower entrainment zone and an upper mixing and combustion zone. 10 kHz OH-PLIF images, and 2D PIV allow the identification of the fate and spatial flame structure. Many flame features were identified and further analyzed using simple but effective image processing methods, where three types of structure in all the flames investigated here: flame holes or breaks; closures; and growing kernels. Insights about the rate of evolution of these features, the dynamics of local extinction, and the sequence of events that lead to re-ignition are reported here. In the lower entrainment zone, the occurrence of the flame break events is counterbalanced by closure events, and the edge propagation appears to control the rate at which the flame holes and closures propagate. The rate of propagation of holes was found to be statistically faster than the rate of closure. As the flames approach blow-off, flame kernels become the main mechanism for flame re-ignition further downstream. The simultaneous OH-PLIF/Stereo PIV

  11. High-Rate Strong-Signal Quantum Cryptography

    Science.gov (United States)

    Yuen, Horace P.

    1996-01-01

    Several quantum cryptosystems utilizing different kinds of nonclassical lights, which can accommodate high intensity fields and high data rate, are described. However, they are all sensitive to loss and both the high rate and the strong-signal character rapidly disappear. A squeezed light homodyne detection scheme is proposed which, with present-day technology, leads to more than two orders of magnitude data rate improvement over other current experimental systems for moderate loss.

  12. Characterization of bio-inspired hair flow sensors for oscillatory airflows: techniques to measure the response for both flow and pressure

    NARCIS (Netherlands)

    Droogendijk, H.; Dagamseh, A.M.K.; Sanders, Remco G.P.; Yntema, Doekle Reinder; Krijnen, Gijsbertus J.M.

    2014-01-01

    Hair sensors for oscillatory airflow, operating in the regime of bulk flow, particle velocity or both, can be characterized by several methods. In this work, we discuss harmonic measurements on MEMS hair flow sensors. To characterize this type of flow sensor the use of three different types of

  13. New insight into the evolution of the vertebrate respiratory system and the discovery of unidirectional airflow in iguana lungs.

    Science.gov (United States)

    Cieri, Robert L; Craven, Brent A; Schachner, Emma R; Farmer, C G

    2014-12-02

    The generally accepted framework for the evolution of a key feature of the avian respiratory system, unidirectional airflow, is that it is an adaptation for efficiency of gas exchange and expanded aerobic capacities, and therefore it has historically been viewed as important to the ability of birds to fly and to maintain an endothermic metabolism. This pattern of flow has been presumed to arise from specific features of the respiratory system, such as an enclosed intrapulmonary bronchus and parabronchi. Here we show unidirectional airflow in the green iguana, a lizard with a strikingly different natural history from that of birds and lacking these anatomical features. This discovery indicates a paradigm shift is needed. The selective drivers of the trait, its date of origin, and the fundamental aerodynamic mechanisms by which unidirectional flow arises must be reassessed to be congruent with the natural history of this lineage. Unidirectional flow may serve functions other than expanded aerobic capacity; it may have been present in the ancestral diapsid; and it can occur in structurally simple lungs.

  14. Testing limits to airflow perturbation device (APD measurements

    Directory of Open Access Journals (Sweden)

    Jamshidi Shaya

    2008-10-01

    Full Text Available Abstract Background The Airflow Perturbation Device (APD is a lightweight, portable device that can be used to measure total respiratory resistance as well as inhalation and exhalation resistances. There is a need to determine limits to the accuracy of APD measurements for different conditions likely to occur: leaks around the mouthpiece, use of an oronasal mask, and the addition of resistance in the respiratory system. Also, there is a need for resistance measurements in patients who are ventilated. Method Ten subjects between the ages of 18 and 35 were tested for each station in the experiment. The first station involved testing the effects of leaks of known sizes on APD measurements. The second station tested the use of an oronasal mask used in conjunction with the APD during nose and mouth breathing. The third station tested the effects of two different resistances added in series with the APD mouthpiece. The fourth station tested the usage of a flexible ventilator tube in conjunction with the APD. Results All leaks reduced APD resistance measurement values. Leaks represented by two 3.2 mm diameter tubes reduced measured resistance by about 10% (4.2 cmH2O·sec/L for control and 3.9 cm H2O·sec/L for the leak. This was not statistically significant. Larger leaks given by 4.8 and 6.4 mm tubes reduced measurements significantly (3.4 and 3.0 cm cmH2O·sec/L, respectively. Mouth resistance measured with a cardboard mouthpiece gave an APD measurement of 4.2 cm H2O·sec/L and mouth resistance measured with an oronasal mask was 4.5 cm H2O·sec/L; the two were not significantly different. Nose resistance measured with the oronasal mask was 7.6 cm H2O·sec/L. Adding airflow resistances of 1.12 and 2.10 cm H2O·sec/L to the breathing circuit between the mouth and APD yielded respiratory resistance values higher than the control by 0.7 and 2.0 cm H2O·sec/L. Although breathing through a 52 cm length of flexible ventilator tubing reduced the APD

  15. Determination of trace elements in seawater by air-flow injection/ICP-MS with chelating resin preconcentration

    International Nuclear Information System (INIS)

    Lee, Kyue-Hyung; Ohshima, Mitsuko; Motomizu, Shoji

    2002-01-01

    Multielement determination of major to trace metals in a deep seawater malt was accomplished by inductively coupled plasma-mass spectrometry (ICP-MS) together with inductively coupled plasma-atomic emission spectrometry (ICP-AES). Major elements, such as Na, K, Mg, and Ca, were measured by ICP-AES and normal continuos nebulization ICP-MS after sample dilution by 10 3 -10 6 fold. Fifteen trace elements in the concentrated metal solutions pretreated with cation-exchange resin or chelating resin could be simultaneously determined by air-flow injection/ICP-mass spectrometry (AFI/ICP-MS). Since the injection volume for AFI/ICP-MS was 25 μl, final samples volumes less than 500 μl were enough for several replicate measurements. Three different preconcentration methods assisted with AFI/ICP-MS were examined and could be successfully applied to a deep seawater malt. The analytical results of rate earth elements (REEs) and Co, Ni, Cu, Zn, Cd, and Pb obtained by AFI/ICP-MS coupled with disk filtration method using iminodiacetate (IDA)-type chelating resin were favorably agreed with the data obtained by AFI/ICP-MS coupled with column preconcentration method using chitosan-based chelating resin. (author)

  16. Numerical analysis of the actual airflow in a solar chimney; Analise numerica do escoamento real de ar em uma chamine solar

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Andre G.; Cortez, Marcio F.B.; Valle, Ramon M.; Brasil, Cristiana S. [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica]. E-mail: ferreira@demec.ufmg.br; fonteboa@demec.ufmg.br; ramon@demec.ufmg.br; tite@demec.ufmg.br

    2000-07-01

    This paper presents a numerical analysis of the turbulent natural convection of the airflow in a solar chimney, under actual solar radiation conditions. The solar chimneys are devices that consist of a transparent radial cover and of a tubular tower positioned in its center. The ground absorbs part of the incident solar radiation on the cover, heating the air in the greenhouse and inducing an upward airflow on the tower. It was developed a model that allows the evaluation of the ground temperature as a function of an energetic balance involving the incident solar radiation. The flow is described by the conservation laws for mass, momentum and thermal energy and the transport equations for the turbulence model (k and e ). A computational code using the Finite Volume Method in Generalized Coordinates was developed to solve these equations. Outlet dimensionless parameters are presented as functions of the radiation time and conditions, besides the unsteady behavior of the ground surface temperature. (author)

  17. The influence of airflow inlet region modifications on the local efficiency of natural draft cooling tower operation

    OpenAIRE

    Hočevar, Marko; Širok, Brane; Dvoršek, Matjaž; Holeček, Nikola; Donevski, Božin

    2015-01-01

    We present the influence of the cooling tower airflow inlet region modifications at the Šoštanj 4 thermal power plant on cooling tower local efficiency. Local efficiency change was estimated based on temperature fields of drift eliminators before and after the reconstruction of the cooling tower. Temperature fields were measured with thermal vision method. The local reduction of cooling tower efficiency was analyzed based on phenomenological relations of heat transfer obtained from the select...

  18. A Capillary-Based Static Phase Separator for Highly Variable Wetting Conditions

    Science.gov (United States)

    Thomas, Evan A.; Graf, John C.; Weislogel, Mark M.

    2010-01-01

    The invention, a static phase separator (SPS), uses airflow and capillary wetting characteristics to passively separate a two-phase (liquid and air) flow. The device accommodates highly variable liquid wetting characteristics. The resultant design allows for a range of wetting properties from about 0 to over 90 advancing contact angle, with frequent complete separation of liquid from gas observed when using appropriately scaled test conditions. Additionally, the design accommodates a range of air-to-liquid flow-rate ratios from only liquid flow to over 200:1 air-to-liquid flow rate. The SPS uses a helix input section with an ice-cream-cone-shaped constant area cross section (see figure). The wedge portion of the cross section is on the outer edge of the helix, and collects the liquid via centripetal acceleration. The helix then passes into an increasing cross-sectional area vane region. The liquid in the helix wedge is directed into the top of capillary wedges in the liquid containment section. The transition from diffuser to containment section includes a 90 change in capillary pumping direction, while maintaining inertial direction. This serves to impinge the liquid into the two off-center symmetrical vanes by the airflow. Rather than the airflow serving to shear liquid away from the capillary vanes, the design allows for further penetration of the liquid into the vanes by the air shear. This is also assisted by locating the air exit ports downstream of the liquid drain port. Additionally, any droplets not contained in the capillary vanes are re-entrained downstream by a third opposing capillary vane, which directs liquid back toward the liquid drain port. Finally, the dual air exit ports serve to slow the airflow down, and to reduce the likelihood of shear. The ports are stove-piped into the cavity to form an unfriendly capillary surface for a wetting fluid to carryover. The liquid drain port is located at the start of the containment region, allowing for

  19. Different histological subtypes of peripheral lung cancer based on emphysema distribution in patients with both airflow limitation and CT-determined emphysema.

    Science.gov (United States)

    Shin, Beomsu; Shin, Sumin; Chung, Myung Jin; Lee, Hyun; Koh, Won-Jung; Kim, Hojoong; Park, Hye Yun

    2017-02-01

    The histological subtypes by peripheral tumor location remain uncharacterized in COPD patients with emphysema. We investigated histologic subtypes of peripheral lung cancers based on the context of heterogeneous emphysema distribution in patients with airflow limitation and CT-determined emphysema. A retrospective, cross-sectional study was conducted using data from 754 patients with airflow limitation and newly-diagnosed primary lung cancers from February 2013 to February 2015. Of these, 230 patients had emphysema, as determined by computed tomography software designed to quantify emphysema. Among the 230 patients, the most common subtype in central lesions (n=84) was squamous cell carcinoma (SCC) (n=64/84, 76%). Adenocarcinoma (ADC) was more frequently observed in peripheral lesions (n=146) than central lesions (58/146 [40%] vs. 4/84 [5%], pemphysema than emphysema areas (43/74 [58%] vs. 15/72 [21%], pemphysema areas than areas without emphysema (44/72 [61%] vs. 13/74 [18%], pemphysema, the main histological subtype of peripheral lung cancer was SCC in emphysema areas and ADC in areas without emphysema. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Characteristics of Turbulent Airflow Deduced from Rapid Surface Thermal Fluctuations: An Infrared Surface Anemometer

    Science.gov (United States)

    Aminzadeh, Milad; Breitenstein, Daniel; Or, Dani

    2017-12-01

    The intermittent nature of turbulent airflow interacting with the surface is readily observable in fluctuations of the surface temperature resulting from the thermal imprints of eddies sweeping the surface. Rapid infrared thermography has recently been used to quantify characteristics of the near-surface turbulent airflow interacting with the evaporating surfaces. We aim to extend this technique by using single-point rapid infrared measurements to quantify properties of a turbulent flow, including surface exchange processes, with a view towards the development of an infrared surface anemometer. The parameters for the surface-eddy renewal (α and β ) are inferred from infrared measurements of a single-point on the surface of a heat plate placed in a wind tunnel with prescribed wind speeds and constant mean temperatures of the surface. Thermally-deduced parameters are in agreement with values obtained from standard three-dimensional ultrasonic anemometer measurements close to the plate surface (e.g., α = 3 and β = 1/26 (ms)^{-1} for the infrared, and α = 3 and β = 1/19 (ms)^{-1} for the sonic-anemometer measurements). The infrared-based turbulence parameters provide new insights into the role of surface temperature and buoyancy on the inherent characteristics of interacting eddies. The link between the eddy-spectrum shape parameter α and the infrared window size representing the infrared field of view is investigated. The results resemble the effect of the sampling height above the ground in sonic anemometer measurements, which enables the detection of larger eddies with higher values of α . The physical basis and tests of the proposed method support the potential for remote quantification of the near-surface momentum field, as well as scalar-flux measurements in the immediate vicinity of the surface.

  1. High School Graduation Rates:Alternative Methods and Implications

    Directory of Open Access Journals (Sweden)

    Jing Miao

    2004-10-01

    Full Text Available The No Child Left Behind Act has brought great attention to the high school graduation rate as one of the mandatory accountability measures for public school systems. However, there is no consensus on how to calculate the high school graduation rate given the lack of longitudinal databases that track individual students. This study reviews literature on and practices in reporting high school graduation rates, compares graduation rate estimates yielded from alternative methods, and estimates discrepancies between alternative results at national, state, and state ethnic group levels. Despite the graduation rate method used, results indicate that high school graduation rates in the U.S. have been declining in recent years and that graduation rates for black and Hispanic students lag substantially behind those of white students. As to graduation rate method preferred, this study found no evidence that the conceptually more complex methods yield more accurate or valid graduation rate estimates than the simpler methods.

  2. Relationship between spontaneous expiratory flow-volume curve pattern and air-flow obstruction in elderly COPD patients.

    Science.gov (United States)

    Nozoe, Masafumi; Mase, Kyoshi; Murakami, Shigefumi; Okada, Makoto; Ogino, Tomoyuki; Matsushita, Kazuhiro; Takashima, Sachie; Yamamoto, Noriyasu; Fukuda, Yoshihiro; Domen, Kazuhisa

    2013-10-01

    Assessment of the degree of air-flow obstruction is important for determining the treatment strategy in COPD patients. However, in some elderly COPD patients, measuring FVC is impossible because of cognitive dysfunction or severe dyspnea. In such patients a simple test of airways obstruction requiring only a short run of tidal breathing would be useful. We studied whether the spontaneous expiratory flow-volume (SEFV) curve pattern reflects the degree of air-flow obstruction in elderly COPD patients. In 34 elderly subjects (mean ± SD age 80 ± 7 y) with stable COPD (percent-of-predicted FEV(1) 39.0 ± 18.5%), and 12 age-matched healthy subjects, we measured FVC and recorded flow-volume curves during quiet breathing. We studied the SEFV curve patterns (concavity/convexity), spirometry results, breathing patterns, and demographics. The SEFV curve concavity/convexity prediction accuracy was examined by calculating the receiver operating characteristic curves, cutoff values, area under the curve, sensitivity, and specificity. Fourteen subjects with COPD had a concave SEFV curve. All the healthy subjects had convex SEFV curves. The COPD subjects who had concave SEFV curves often had very severe airway obstruction. The percent-of-predicted FEV(1)% (32.4%) was the most powerful SEFV curve concavity predictor (area under the curve 0.92, 95% CI 0.83-1.00), and had the highest sensitivity (0.93) and specificity (0.88). Concavity of the SEFV curve obtained during tidal breathing may be a useful test for determining the presence of very severe obstruction in elderly patients unable to perform a satisfactory FVC maneuver.

  3. Study on the Effects of Evaporation and Condensation on the Underfloor Space of Japanese Detached Houses Using CFD Analysis

    Directory of Open Access Journals (Sweden)

    Wonseok Oh

    2017-06-01

    Full Text Available The purpose of this study is to determine the effects of evaporation and condensation on the underfloor space of Japanese detached houses. In this underfloor space, natural ventilation is applied. A typical Japanese wooden detached house is raised 0.3–0.5 m over an underfloor space made of concrete. The bottom of the underfloor space is usually paved with concrete, and the ceiling which is directly underneath the indoor occupant zone is made of wood. Computational fluid dynamics (CFD analysis is applied to calculate the rates of the evaporation and condensation generated inside the underfloor under two conditions, namely, a constant (fixed outdoor environmental condition and a fluctuating environmental condition. In the constant condition, we verified the effects of the outdoor humidity, ventilation rate, and ratio of wetted surface (RWS, ω on the evaporation and condensation inside the underfloor space. In this condition, the rate of evaporation and condensation was quantified considering the varying outdoor humidity between 0 to 100%, and the RWS (ω = 1 or 0. In addition, the influence of the different ventilation rates at 1.0 m/s for normal and 0.05 m/s for stagnant wind velocities were confirmed. Under fluctuating environmental conditions, the outdoor conditions change for 24 h, so the RWS varies. Therefore, the rate of evaporation and condensation, the amount of the condensed water, and the area of condensation were confirmed. The results were as follows: with a high airflow rate on the underfloor space, the evaporation and condensation phenomenon occurs continuously and is easily affected by outdoor humidity, while under low airflow rate conditions, only the condensation appeared steadily. If the wind velocity is strong, the convective mass transfer on a surface becomes large. In a condition of the outdoor humidity and the airflow rate on underfloor are high, condensation mainly occurs in a corner of the underfloor space due to high

  4. Evaporation of a volatile organic compound in a hygroscopic soil - influence of the airflow and its VOC vapour saturation

    OpenAIRE

    Naon , Bétaboalé; Benet , Jean-Claude; Cousin , Bruno; Cherblanc , Fabien; Chammari , Ali

    2013-01-01

    International audience; This article presents an experimental and theoretical study of VOC volatilization in soil during a decontamination process by vapour extraction or venting. A phase change law is proposed in the case of a sandy-silty soil when the convective gaseous phase is vapour-charged. A simple experimental method for analyzing the phase change is presented. Finally, an efficiency coefficient is introduced to quantify the contribution of airflow velocity on venting.

  5. High School Graduation Rates:Alternative Methods and Implications

    OpenAIRE

    Jing Miao; Walt Haney

    2004-01-01

    The No Child Left Behind Act has brought great attention to the high school graduation rate as one of the mandatory accountability measures for public school systems. However, there is no consensus on how to calculate the high school graduation rate given the lack of longitudinal databases that track individual students. This study reviews literature on and practices in reporting high school graduation rates, compares graduation rate estimates yielded from alternative methods, and estimates d...

  6. Impact of turbulence anisotropy near walls in room airflow

    DEFF Research Database (Denmark)

    Schälin, A.; Nielsen, Peter Vilhelm

    2004-01-01

    The influence of different turbulence models used in computational fluid dynamics predictions is studied in connection with room air movement. The turbulence models used are the high Re-number k–e model and the high Re- number Reynolds stress model (RSM). The three-dimensional wall jet is selected...... in a three- dimensional wall jet by the k–e turbulence model. Furthermore, it is shown that the growth rate can be predicted to a certain extent by the RSM with wall reflection terms. The flow in a deep room can be strongly influenced by details as the growth rate of a three-dimensional wall jet. Predictions...... for the work. The growth rate parallel to the wall in a three-dimensional wall jet is large compared with the growth rate perpendicular to the wall, and it is large compared with the growth rate in a free circular jet. It is shown that it is not possible to predict the high growth rate parallel with a surface...

  7. Comparison of turbulence models for numerical calculation of airflow in an annex 20 room

    DEFF Research Database (Denmark)

    Voigt, Lars P. K.

    2000-01-01

    The report deals with 2-D numerical calculation of room airflow in an isothermal annex 20 room. The report documents the ability of the flow solver EllipSys2D to give results in good agreement with measurements for the specified test case. The flow solver is a finite volume code solving the Reyno.......Applying theory for a two-dimensional wall jet, measurements are compared with calculated values of the turbulent kinetic energy....... the Reynolds Averaged Navier Stokes equations.Five two-equation turbulence models were tested. These are the standard k-epsilon model, the low-Reynolds number k-epison model by Launder & Sharma, the k-omega model by Wilcox, the k-omega baseline (BSL) model by Menter and the k-omega Shear Stress Transport (SST...

  8. High rate response of ultra-high-performance fiber-reinforced concretes under direct tension

    Energy Technology Data Exchange (ETDEWEB)

    Tran, Ngoc Thanh [Department of Civil and Environmental Engineering, Sejong University, 98 Gunja-Dong, Gwangjin-Gu, Seoul 143-747 (Korea, Republic of); Tran, Tuan Kiet [Department of Civil and Environmental Engineering, Sejong University, 98 Gunja-Dong, Gwangjin-Gu, Seoul 143-747 (Korea, Republic of); Department of Civil Engineering and Applied Mechanics, Ho Chi Minh City University of Technology and Education, 01 Vo Van Ngan, Thu Duc District, Ho Chi Minh City (Viet Nam); Kim, Dong Joo, E-mail: djkim75@sejong.ac.kr [Department of Civil and Environmental Engineering, Sejong University, 98 Gunja-Dong, Gwangjin-Gu, Seoul 143-747 (Korea, Republic of)

    2015-03-15

    The tensile response of ultra-high-performance fiber-reinforced concretes (UHPFRCs) at high strain rates (5–24 s{sup −} {sup 1}) was investigated. Three types of steel fibers, including twisted, long and short smooth steel fibers, were added by 1.5% volume content in an ultra high performance concrete (UHPC) with a compressive strength of 180 MPa. Two different cross sections, 25 × 25 and 25 × 50 mm{sup 2}, of tensile specimens were used to investigate the effect of the cross section area on the measured tensile response of UHPFRCs. Although all the three fibers generated strain hardening behavior even at high strain rates, long smooth fibers produced the highest tensile resistance at high rates whereas twisted fiber did at static rate. The breakages of twisted fibers were observed from the specimens tested at high strain rates unlike smooth steel fibers. The tensile behavior of UHPFRCs at high strain rates was clearly influenced by the specimen size, especially in post-cracking strength.

  9. Characteristics of airflow and particle deposition in COPD current smokers

    Science.gov (United States)

    Zou, Chunrui; Choi, Jiwoong; Haghighi, Babak; Choi, Sanghun; Hoffman, Eric A.; Lin, Ching-Long

    2017-11-01

    A recent imaging-based cluster analysis of computed tomography (CT) lung images in a chronic obstructive pulmonary disease (COPD) cohort identified four clusters, viz. disease sub-populations. Cluster 1 had relatively normal airway structures; Cluster 2 had wall thickening; Cluster 3 exhibited decreased wall thickness and luminal narrowing; Cluster 4 had a significant decrease of luminal diameter and a significant reduction of lung deformation, thus having relatively low pulmonary functions. To better understand the characteristics of airflow and particle deposition in these clusters, we performed computational fluid and particle dynamics analyses on representative cluster patients and healthy controls using CT-based airway models and subject-specific 3D-1D coupled boundary conditions. The results show that particle deposition in central airways of cluster 4 patients was noticeably increased especially with increasing particle size despite reduced vital capacity as compared to other clusters and healthy controls. This may be attributable in part to significant airway constriction in cluster 4. This study demonstrates the potential application of cluster-guided CFD analysis in disease populations. NIH Grants U01HL114494 and S10-RR022421, and FDA Grant U01FD005837.

  10. Force and Motion Characteristics of Contamination Particles near the High Voltage End of UHVDC Insulator

    Directory of Open Access Journals (Sweden)

    Lei Lan

    2017-07-01

    Full Text Available It is important to reveal the relations of physical factors to deposition of contaminants on insulator. In this paper, the simulation model of high voltage end of insulator was established to study the force and motion characteristics of particles affected by electric force and airflow drag force near the ultra-high voltage direct current (UHVDC insulator. By finite element method, the electric field was set specially to be similar to the one near practical insulator, the steady fluid field was simulated. The electric force and air drag force were loaded on the uniformly charged particles. The characteristics of the two forces on particles, the relationship between quantity of electric charge on particles and probability of particles contacting the insulator were analyzed. It was found that, near the sheds, airflow drag force on particles is significantly greater than electric force with less electric charge. As the charge multiplies, electric force increases linearly, airflow drag force grows more slowly. There is a trend that the magnitude of electric force and drag force is going to similar. Meanwhile, the probability of particles contacting the insulator is increased too. However, at a certain level of charge which has different value with different airflow velocity, the contact probability has extremum here. After exceeding the value, as the charge increasing, the contact probability decreases gradually.

  11. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D.; Shaffer, M.

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Warme und Feuchte instationar Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  12. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D. [IBACOS, Inc., Pittsburgh, PA (United States); Shaffer, M. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Wärme und Feuchte instationär Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  13. Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

    Energy Technology Data Exchange (ETDEWEB)

    2017-04-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  14. Simulation of airflow and aerodynamic forces acting on a commercial turbine ventilator

    International Nuclear Information System (INIS)

    Farahani, A.S.; Nor Mariah Adam; Khairol Anuar

    2009-01-01

    Full text: This study is concerned with performing simulation of airflow using Computational Fluid Dynamics (CFD) technique code name FLUENT so as to visualize the flow behavior around and within turbine ventilator in addition to determining the aerodynamic forces acting on turbine ventilator during operation and comparing the simulated results to the wind tunnel experiment. To achieve this, Realizable k-ε and RSM turbulence models are used by taking advantage of moving mesh method to simulate the rotation of turbine ventilator and the consequent results are obtained through the sequential process which ensures accuracy of the computations. The results demonstrated that, the RSM turbulence model shows the best performance on flow visualization and predicting the aerodynamic forces acting on a turbine ventilator. Results from this work would lead us to a noticeable increase in efficiency of future turbine ventilator by enhancing the shape of inner vanes, and redesign them using CFD technique. (author)

  15. Airflow measurements at a wavy air-water interface using PIV and LIF

    Science.gov (United States)

    Buckley, Marc P.; Veron, Fabrice

    2017-11-01

    Physical phenomena at an air-water interface are of interest in a variety of flows with both industrial and natural/environmental applications. In this paper, we present novel experimental techniques incorporating a multi-camera multi-laser instrumentation in a combined particle image velocimetry and laser-induced fluorescence system. The system yields accurate surface detection thus enabling velocity measurements to be performed very close to the interface. In the application presented here, we show results from a laboratory study of the turbulent airflow over wind driven surface waves. Accurate detection of the wavy air-water interface further yields a curvilinear coordinate system that grants practical and easy implementation of ensemble and phase averaging routines. In turn, these averaging techniques allow for the separation of mean, surface wave coherent, and turbulent velocity fields. In this paper, we describe the instrumentation and techniques and show several data products obtained on the air-side of a wavy air-water interface.

  16. Drying of Agricultural Products Using Long Wave Infrared Radiation(Part 2). Drying of Welsh Onion

    International Nuclear Information System (INIS)

    Itoh, K.; Han, C.S.

    1995-01-01

    The investigation was carried out to clarify the intermittent drying characteristics for welsh onion use of long-wave infrared radiation. When compared with two other methods: use of air and vacuum freezing, this method showed significantly high rate of drying. The experiments were carried out analyzing the influence of different lengths of the welsh onion, different rate of radiation and different temperature of the airflow. The obtained results were as follows: 1. The rate of drying increases as the length of welsh onion decrease and the rate of radiation increase. 2. The airflow, temperature does not influence to the rate of drying. 3. The increasing of the drying time considerably aggravate the quality the dried welsh onion

  17. Airflow obstruction: is it asthma or is it COPD?

    Directory of Open Access Journals (Sweden)

    Rogliani P

    2016-11-01

    Full Text Available Paola Rogliani, Josuel Ora, Ermanno Puxeddu, Mario Cazzola Department of Systems Medicine, Tor Vergata University of Rome, Rome, Italy Abstract: Despite the availability of guideline recommendations, diagnostic confusion between COPD and asthma appears common, and often it is very difficult to decide whether the obstruction is caused by asthma or COPD in a patient with airway obstruction. However, there are well-defined features that help in differentiating asthma from COPD in the presence of fixed airflow obstruction. Nonetheless, the presentations of asthma and COPD can converge and mimic each other, making it difficult to give these patients a diagnosis of either condition. The association of asthma and COPD in the same patient has been designated mixed asthma–COPD phenotype or overlap syndrome. However, since the absence of a clear definition and the inclusion of patients with different characteristics under this umbrella term, it may not facilitate treatment decisions, especially in the absence of clinical trials addressing this heterogeneous population. We are realizing that neither asthma nor COPD are single diseases, but rather syndromes consisting of several endotypes and phenotypes, consequently comprising a spectrum of diseases that must be recognized and adequately treated with targeted therapy. Therefore, we must treat patients by personalizing therapy on the basis of those treatable traits present in each subject. Keywords: airway obstruction, asthma, ACOS, chronic obstructive pulmonary disease

  18. High-rate lithium thionyl chloride cells

    Science.gov (United States)

    Goebel, F.

    1982-03-01

    A high-rate C cell with disc electrodes was developed to demonstrate current rates which are comparable to other primary systems. The tests performed established the limits of abuse beyond which the cell becomes hazardous. Tests include: impact, shock, and vibration tests; temperature cycling; and salt water immersion of fresh cells.

  19. Quantum data locking for high-rate private communication

    OpenAIRE

    Lupo, Cosmo; Lloyd, Seth

    2015-01-01

    We show that, if the accessible information is used as a security quantifier, quantum channels with a certain symmetry can convey private messages at a tremendously high rate, as high as less than one bit below the rate of non-private classical communication. This result is obtained by exploiting the quantum data locking effect. The price to pay to achieve such a high private communication rate is that accessible information security is in general not composable. However, composable security ...

  20. Thrombus Formation at High Shear Rates.

    Science.gov (United States)

    Casa, Lauren D C; Ku, David N

    2017-06-21

    The final common pathway in myocardial infarction and ischemic stroke is occlusion of blood flow from a thrombus forming under high shear rates in arteries. A high-shear thrombus forms rapidly and is distinct from the slow formation of coagulation that occurs in stagnant blood. Thrombosis at high shear rates depends primarily on the long protein von Willebrand factor (vWF) and platelets, with hemodynamics playing an important role in each stage of thrombus formation, including vWF binding, platelet adhesion, platelet activation, and rapid thrombus growth. The prediction of high-shear thrombosis is a major area of biofluid mechanics in which point-of-care testing and computational modeling are promising future directions for clinically relevant research. Further research in this area will enable identification of patients at high risk for arterial thrombosis, improve prevention and treatment based on shear-dependent biological mechanisms, and improve blood-contacting device design to reduce thrombosis risk.

  1. Unemployment in chronic airflow obstruction around the world: results from the BOLD study.

    Science.gov (United States)

    Grønseth, Rune; Erdal, Marta; Tan, Wan C; Obaseki, Daniel O; Amaral, Andre F S; Gislason, Thorarinn; Juvekar, Sanjay K; Koul, Parvaiz A; Studnicka, Michael; Salvi, Sundeep; Burney, Peter; Buist, A Sonia; Vollmer, William M; Johannessen, Ane

    2017-09-01

    We aimed to examine associations between chronic airflow obstruction (CAO) and unemployment across the world.Cross-sectional data from 26 sites in the Burden of Obstructive Lung Disease (BOLD) study were used to analyse effects of CAO on unemployment. Odds ratios for unemployment in subjects aged 40-65 years were estimated using a multilevel mixed-effects generalised linear model with study site as random effect. Site-by-site heterogeneity was assessed using individual participant data meta-analyses.Out of 18 710 participants, 11.3% had CAO. The ratio of unemployed subjects with CAO divided by subjects without CAO showed large site discrepancies, although these were no longer significant after adjusting for age, sex, smoking and education. The site-adjusted odds ratio (95% CI) for unemployment was 1.79 (1.41-2.27) for CAO cases, decreasing to 1.43 (1.14-1.79) after adjusting for sociodemographic factors, comorbidities and forced vital capacity. Of other covariates that were associated with unemployment, age and education were important risk factors in high-income sites (4.02 (3.53-4.57) and 3.86 (2.80-5.30), respectively), while female sex was important in low- to middle-income sites (3.23 (2.66-3.91)).In the global BOLD study, CAO was associated with increased levels of unemployment, even after adjusting for sociodemographic factors, comorbidities and lung function. Copyright ©ERS 2017.

  2. High Heating Rates Affect Greatly the Inactivation Rate of Escherichia coli

    Science.gov (United States)

    Huertas, Juan-Pablo; Aznar, Arantxa; Esnoz, Arturo; Fernández, Pablo S.; Iguaz, Asunción; Periago, Paula M.; Palop, Alfredo

    2016-01-01

    Heat resistance of microorganisms can be affected by different influencing factors. Although, the effect of heating rates has been scarcely explored by the scientific community, recent researches have unraveled its important effect on the thermal resistance of different species of vegetative bacteria. Typically heating rates described in the literature ranged from 1 to 20°C/min but the impact of much higher heating rates is unclear. The aim of this research was to explore the effect of different heating rates, such as those currently achieved in the heat exchangers used in the food industry, on the heat resistance of Escherichia coli. A pilot plant tubular heat exchanger and a thermoresistometer Mastia were used for this purpose. Results showed that fast heating rates had a deep impact on the thermal resistance of E. coli. Heating rates between 20 and 50°C/min were achieved in the heat exchanger, which were much slower than those around 20°C/s achieved in the thermoresistometer. In all cases, these high heating rates led to higher inactivation than expected: in the heat exchanger, for all the experiments performed, when the observed inactivation had reached about seven log cycles, the predictions estimated about 1 log cycle of inactivation; in the thermoresistometer these differences between observed and predicted values were even more than 10 times higher, from 4.07 log cycles observed to 0.34 predicted at a flow rate of 70 mL/min and a maximum heating rate of 14.7°C/s. A quantification of the impact of the heating rates on the level of inactivation achieved was established. These results point out the important effect that the heating rate has on the thermal resistance of E. coli, with high heating rates resulting in an additional sensitization to heat and therefore an effective food safety strategy in terms of food processing. PMID:27563300

  3. Semi-solid electrodes having high rate capability

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Yet-Ming; Duduta, Mihai; Holman, Richard; Limthongkul, Pimpa; Tan, Taison

    2017-11-28

    Embodiments described herein relate generally to electrochemical cells having high rate capability, and more particularly to devices, systems and methods of producing high capacity and high rate capability batteries having relatively thick semi-solid electrodes. In some embodiments, an electrochemical cell includes an anode, a semi-solid cathode that includes a suspension of an active material and a conductive material in a liquid electrolyte, and an ion permeable membrane disposed between the anode and the cathode. The semi-solid cathode has a thickness in the range of about 250 .mu.m-2,500 .mu.m, and the electrochemical cell has an area specific capacity of at least 5 mAh/cm.sup.2 at a C-rate of C/2.

  4. Solidification at the High and Low Rate Extreme

    Energy Technology Data Exchange (ETDEWEB)

    Meco, Halim [Iowa State Univ., Ames, IA (United States)

    2004-12-19

    The microstructures formed upon solidification are strongly influenced by the imposed growth rates on an alloy system. Depending on the characteristics of the solidification process, a wide range of growth rates is accessible. The prevailing solidification mechanisms, and thus the final microstructure of the alloy, are governed by these imposed growth rates. At the high rate extreme, for instance, one can have access to novel microstructures that are unattainable at low growth rates. While the low growth rates can be utilized for the study of the intrinsic growth behavior of a certain phase growing from the melt. Although the length scales associated with certain processes, such as capillarity, and the diffusion of heat and solute, are different at low and high rate extremes, the phenomena that govern the selection of a certain microstructural length scale or a growth mode are the same. Consequently, one can analyze the solidification phenomena at both high and low rates by using the same governing principles. In this study, we examined the microstructural control at both low and high extremes. For the high rate extreme, the formation of crystalline products and factors that control the microstructure during rapid solidification by free-jet melt spinning are examined in Fe-Si-B system. Particular attention was given to the behavior of the melt pool at different quench-wheel speeds. Since the solidification process takes place within the melt-pool that forms on the rotating quench-wheel, we examined the influence of melt-pool dynamics on nucleation and growth of crystalline solidification products and glass formation. High-speed imaging of the melt-pool, analysis of ribbon microstructure, and measurement of ribbon geometry and surface character all indicate upper and lower limits for melt-spinning rates for which nucleation can be avoided, and fully amorphous ribbons can be achieved. Comparison of the relevant time scales reveals that surface-controlled melt

  5. Dynamic High-Temperature Characterization of an Iridium Alloy in Compression at High Strain Rates

    Energy Technology Data Exchange (ETDEWEB)

    Song, Bo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Experimental Environment Simulation Dept.; Nelson, Kevin [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Mechanics of Materials Dept.; Lipinski, Ronald J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Nuclear Fuel Cycle Technology Dept.; Bignell, John L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Structural and Thermal Analysis Dept.; Ulrich, G. B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Radioisotope Power Systems Program; George, E. P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Radioisotope Power Systems Program

    2014-06-01

    Iridium alloys have superior strength and ductility at elevated temperatures, making them useful as structural materials for certain high-temperature applications. However, experimental data on their high-temperature high-strain-rate performance are needed for understanding high-speed impacts in severe elevated-temperature environments. Kolsky bars (also called split Hopkinson bars) have been extensively employed for high-strain-rate characterization of materials at room temperature, but it has been challenging to adapt them for the measurement of dynamic properties at high temperatures. Current high-temperature Kolsky compression bar techniques are not capable of obtaining satisfactory high-temperature high-strain-rate stress-strain response of thin iridium specimens investigated in this study. We analyzed the difficulties encountered in high-temperature Kolsky compression bar testing of thin iridium alloy specimens. Appropriate modifications were made to the current high-temperature Kolsky compression bar technique to obtain reliable compressive stress-strain response of an iridium alloy at high strain rates (300 – 10000 s-1) and temperatures (750°C and 1030°C). Uncertainties in such high-temperature high-strain-rate experiments on thin iridium specimens were also analyzed. The compressive stress-strain response of the iridium alloy showed significant sensitivity to strain rate and temperature.

  6. High Strain Rate Characterisation of Composite Materials

    DEFF Research Database (Denmark)

    Eriksen, Rasmus Normann Wilken

    -reinforced polymers, were considered, and it was first shown that the loading history controls equilibrium process. Then the High-speed servo-hydraulic test machine was analysed in terms its ability to create a state of constant strain rate in the specimen. The invertible inertial forces in the load train prevented...... from designing and constructing a high-speed servo-hydraulic test machine and by performing a comprehensive test series. The difficulties encountered in the test work could be addressed with the developed analysis. The conclusion was that the High-speed servo-hydraulic test machine is less suited...... for testing fibre-reinforced polymers due to their elastic behaviour and low strain to failure. This is problematic as the High-speed servo-hydraulic test machine closes the gap between quasi-static tests rates and lower strain rates, which are achievable with the Split Hopkinson Pressure Bar. The Split...

  7. Experimental observation of transient δ18O interaction between snow and advective airflow under various temperature gradient conditions

    Directory of Open Access Journals (Sweden)

    P. P. Ebner

    2017-07-01

    Full Text Available Stable water isotopes (δ18O obtained from snow and ice samples of polar regions are used to reconstruct past climate variability, but heat and mass transport processes can affect the isotopic composition. Here we present an experimental study on the effect of airflow on the snow isotopic composition through a snow pack in controlled laboratory conditions. The influence of isothermal and controlled temperature gradient conditions on the δ18O content in the snow and interstitial water vapour is elucidated. The observed disequilibrium between snow and vapour isotopes led to the exchange of isotopes between snow and vapour under non-equilibrium processes, significantly changing the δ18O content of the snow. The type of metamorphism of the snow had a significant influence on this process. These findings are pertinent to the interpretation of the records of stable isotopes of water from ice cores. These laboratory measurements suggest that a highly resolved climate history is relevant for the interpretation of the snow isotopic composition in the field.

  8. Study on heat and mass transfer characteristics of humid air-flow in a fin bundle

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-Hwi [Air-Conditioner Research Laboratory, LG Electronics, Seoul 153-082 (Korea); Koyama, Shigeru; Kuwahara, Ken [Department of Energy and Environmental Engineering, Kyushu University, Kasuga, Fukuoka 816-8580 (Japan); Kwon, Jeong-Tae [Department of Mechanical Engineering, Hoseo University, Asan, Chungnam 336-795 (Korea); Park, Byung-Duck [School of Mechanical and Automotive Engineering, Kyungpook National University, Sangju, Gyeongbuk 742-711 (Korea)

    2010-11-15

    This paper deals with the heat and mass transfer characteristics of humid air-flow under frosting conditions. A slit fin bundle was used for the simulation of fins of a heat exchanger. The effects of the cooling block temperature, air humidity and air velocity on the frosting characteristics were experimentally investigated. The frosted mass was affected considerably by the cooling block temperature and air humidity. However, the effect of air velocity on it was not so large. The pressure drop was affected remarkably by all experimental parameters in this study. Local heat flux distribution and frost thickness distribution on each fin were predicted from the measured fin temperatures and the mass and energy conservation equations on the frost surface and inside the frost layer. (author)

  9. Influence of agitation speeds and aeration rates on the Xylanase activity of Aspergillus niger SS7

    Directory of Open Access Journals (Sweden)

    Yasser Bakri

    2011-08-01

    Full Text Available In this study, the effect of agitation and aeration rates on xylanase activity of Aspergillus niger SS7 in 3-litre stirred tank bioreactor was investigated. The agitation rates tested were 100, 200 and 300 rpm at each airflow rates of 0.5, 1.0 and 1.5 vvm. The maximum xylanase activity in mono- agitator system was at the agitation speed of 200 rpm and aeration rate of 1.0 vvm. In bi-agitator system, at low agitation speed (100 rpm, the xylanase activity was enhanced by 13% compared to mono- agitator system for an aeration rate of 1.0 vvm. Xylanase productivity in continuous culture was higher by approximately 3.5 times than in batch culture.

  10. Influence of forced internal air circulation on airflow distribution and heat transfer in a gas double-dynamic solid-state fermentation bioreactor.

    Science.gov (United States)

    Chen, Hongzhang; Qin, Lanzhi; Li, Hongqiang

    2014-02-01

    Internal air circulation affects the temperature field distribution in a gas double-dynamic solid-state fermentation bioreactor (GDSFB). To enhance heat transfer through strengthening internal air circulation in a GDSFB, we put an air distribution plate (ADP) into the bioreactor and studied the effects of forced internal air circulation on airflow, heat transfer, and cellulase activity of Trichoderma viride L3. Results showed that ADP could help form a steady and uniform airflow distribution, and with gas-guide tubes, air reversal was formed inside the bioreactor, thus resulting in a smaller temperature difference between medium and air by enhancing convective heat transfer inside the bioreactor. Using an ADP of 5.35 % aperture ratio caused a 1 °C decrease in the average temperature difference during the solid-state fermentation process of T. viride L3. Meanwhile, the cellulase activity of T. viride L3 increased by 13.5 %. The best heat-transfer effect was attained when using an ADP of 5.35 % aperture ratio and setting the fan power to 125 V (4.81 W) in the gas double-dynamic solid-state fermentation (GDSF) process. An option of suitable aperture ratio and fan power may be conducive to ADPs' industrial amplification.

  11. Authoritative school climate and high school dropout rates.

    Science.gov (United States)

    Jia, Yuane; Konold, Timothy R; Cornell, Dewey

    2016-06-01

    This study tested the association between school-wide measures of an authoritative school climate and high school dropout rates in a statewide sample of 315 high schools. Regression models at the school level of analysis used teacher and student measures of disciplinary structure, student support, and academic expectations to predict overall high school dropout rates. Analyses controlled for school demographics of school enrollment size, percentage of low-income students, percentage of minority students, and urbanicity. Consistent with authoritative school climate theory, moderation analyses found that when students perceive their teachers as supportive, high academic expectations are associated with lower dropout rates. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  12. High-repetition-rate short-pulse gas discharge.

    Science.gov (United States)

    Tulip, J; Seguin, H; Mace, P N

    1979-09-01

    A high-average-power short-pulse gas discharge is described. This consists of a volume-preionized transverse discharge of the type used in gas lasers driven by a Blumlein energy storage circuit. The Blumlein circuit is fabricated from coaxial cable, is pulse-charged from a high-repetition-rate Marx-bank generator, and is switched by a high-repetition-rate segmented rail gap. The operation of this discharge under conditions typical of rare-gas halide lasers is described. A maximum of 900 pps was obtained, giving a power flow into the discharge of 30 kW.

  13. HIGH-RATE DISINFECTION TECHNIQUES FOR COMBIND SEWER OVERFLOW

    Science.gov (United States)

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH )...

  14. Introduction to State Estimation of High-Rate System Dynamics.

    Science.gov (United States)

    Hong, Jonathan; Laflamme, Simon; Dodson, Jacob; Joyce, Bryan

    2018-01-13

    Engineering systems experiencing high-rate dynamic events, including airbags, debris detection, and active blast protection systems, could benefit from real-time observability for enhanced performance. However, the task of high-rate state estimation is challenging, in particular for real-time applications where the rate of the observer's convergence needs to be in the microsecond range. This paper identifies the challenges of state estimation of high-rate systems and discusses the fundamental characteristics of high-rate systems. A survey of applications and methods for estimators that have the potential to produce accurate estimations for a complex system experiencing highly dynamic events is presented. It is argued that adaptive observers are important to this research. In particular, adaptive data-driven observers are advantageous due to their adaptability and lack of dependence on the system model.

  15. Visualization by discharge illumination technique and modification by plasma actuator of rarefied Mach 2 airflow around a cylinder

    International Nuclear Information System (INIS)

    Leger, L; Depussay, E; Sellam, M; Barbosa, E

    2013-01-01

    The use of plasma actuators for flow control has received considerable attention in recent years. This kind of device seems to be an appropriate means of raising abilities in flow control thanks to total electric control, no moving parts and a fast response time. The experimental work presented here shows, firstly, the non-intrusive character of the visualization of the density field of an airflow around a cylinder obtained using a plasma luminescence technique. Experiments are made in a continuous supersonic wind tunnel. The static pressure in the flow is 8 Pa, the mean free path is about 0.3 mm and the airflow velocity is 510 m s −1 . Pressure measurements obtained by means of glass Pitot tube without the visualization discharge are proposed. Measured and simulated pressure profiles are in good agreement in the region near the cylinder. There is good correlation between numerical simulations of the supersonic flow field, analytical model predictions and experimental flow visualizations obtained by a plasma luminescence technique. Consequently, we show that the plasma luminescence technique is non-intrusive. Secondly, the effect of a dc discharge on a supersonic rarefied air flow around a cylinder is studied. An electrode is flush mounted on the cylinder. Stagnation pressure profiles are examined for different electrode positions on the cylinder. A shock wave modification depending on the electrode location is observed. The discharge placed at the upstream stagnation point induces an upstream shift of the bow shock, whereas a modification of the shock wave shape is observed when it is placed at 45° or 90°. (paper)

  16. Development of ultra high speed photographic system using high repetition rate visible laser

    International Nuclear Information System (INIS)

    Lee, Jong Min; Cha, Byung Hun; Kim, Sung Ho; Kim, Jung Bog; Lim, Chang Hwan; Cha, Hyung Ki; Song, Kyu Seok; Lee, Byung Deok; Rhi, Jong Hoon; Baik, Dae Hyun; Han, Jae Min; Rho, Si Pyo; Lee, Byung Cheol; Jeong, Do Yung; Choi, An Seong; Jeong, Chan Ik; Park, Dae Ung; Jeong, Sung Min; Lee, Sang Kil; Kim, Heon Jun; Jang, Rae gak; Jo, Do Hun; Park, Min Young

    1992-12-01

    The goal of this project is to develop and commercialize a high speed photographic system equipped with a high repetition rate visible laser. The developed system provides the characteristics of high time resolution and large number of frames. The system consists of 10 W air cooled CVL or a 30 W water cooled CVL, a rotating drum-type high speed camera with the framing rate of 35,000 fps, and a automatic control device. The system has the performance of 10 nsec time resolution, 35,000 fps framing rate, and 250 picture frames. The high speed photographic systems are widely applied to the fields such as high-efficient engine development, high-speed vibration analysis, shock wave propagation study, flow visualization analysis, weapon development, etc. (Author)

  17. Technology development activities for housing research animals on Space Station Freedom

    Science.gov (United States)

    Jenner, Jeffrey W.; Garin, Vladimir M.; Nguyen, Frank D.

    1991-01-01

    The development and design of animal facilities are described in terms of the technological needs for NASA's Biological Flight Research Laboratory. Animal habitats are presented with illustrations which encompass waste-collection techniques for microgravity conditions that reduce the need for crew participation. The technology is intended to be highly compatible with animal morphology, and airflow is employed as the primary mechanism of waste control. The airflow can be utilized in the form of localized high-speed directed flow that simultaneously provides a clean animal habitat and low airflow rates. The design of an animal-habitat testbed is presented which capitalizes on contamination-control mechanisms and suitable materials for microgravity conditions. The developments in materials and technologies represent significant contributions for the design of the centrifuge facilities for the Space Station Freedom.

  18. Quantum data locking for high-rate private communication

    International Nuclear Information System (INIS)

    Lupo, Cosmo; Lloyd, Seth

    2015-01-01

    We show that, if the accessible information is used as a security quantifier, quantum channels with a certain symmetry can convey private messages at a tremendously high rate, as high as less than one bit below the rate of non-private classical communication. This result is obtained by exploiting the quantum data locking effect. The price to pay to achieve such a high private communication rate is that accessible information security is in general not composable. However, composable security holds against an eavesdropper who is forced to measure her share of the quantum system within a finite time after she gets it. (paper)

  19. Airflow Dynamics over a Beach and Foredune System with Large Woody Debris

    Directory of Open Access Journals (Sweden)

    Michael J. Grilliot

    2018-04-01

    Full Text Available Airflow dynamics over beach-foredune systems can be complex. Although a great deal is known about the effects of topographic forcing and vegetation cover on wind-field modification, the role of large woody debris (LWD as a roughness element and modifier of boundary layer flow is relatively understudied. Individual pieces of LWD are non-porous elements that impose bluff body effects and induce secondary flow circulation that varies with size, density, and arrangement. Large assemblages of LWD are common on beaches near forested watersheds and collectively have a degree of porosity that increases aerodynamic roughness in ways that are not fully understood. A field study on a mesotidal sandy beach with a scarped foredune (Calvert Island, British Columbia, Canada shows that LWD influences flow patterns and turbulence levels. Overall mean and fluctuating energy decline as flow transitions across LWD, while mean energy is converted to turbulent energy. Such flow alterations have implications for sand transport pathways and resulting sedimentation patterns, primarily by inducing deposition within the LWD matrix.

  20. High Graduate Unemployment Rate and Taiwanese Undergraduate Education

    Science.gov (United States)

    Wu, Chih-Chun

    2011-01-01

    An expansion in higher education in combination with the recent global economic recession has resulted in a high college graduate unemployment rate in Taiwan. This study investigates how the high unemployment rate and financial constraints caused by economic cutbacks have shaped undergraduates' class choices, job needs, and future income…

  1. Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4)).

    Science.gov (United States)

    Below, Harald; Ryll, Sylvia; Empen, Klaus; Dornquast, Tina; Felix, Stefan; Rosenau, Heike; Kramer, Sebastian; Kramer, Axel

    2010-09-21

    In a cardiac procedure room, ventilated by a ventilation and air-conditioning system with turbulent mixed airflow, a protection zone in the operating area could be defined through visualization of airflows. Within this protection zone, no turbulence was detectable in the room air.Under the given conditions, disinfection of all surfaces including all furniture and equipment after the last operation and subsequent draping of furniture and all equipment that could not be removed from the room with sterile surgical drapes improved the indoor room air quality from cleanroom class C to cleanroom class B. This also allows procedures with elevated requirements to be performed in room class 1b.

  2. Association of emphysema-like lung on cardiac computed tomography and mortality in persons without airflow obstruction: the Multi-Ethnic Study of Atherosclerosis (MESA) Lung Study

    Science.gov (United States)

    Oelsner, Elizabeth C.; Hoffman, Eric A.; Folsom, Aaron R.; Carr, J. Jeffrey; Enright, Paul L.; Kawut, Steven M.; Kronmal, Richard; Lederer, David; Lima, Joao A. C.; Lovasi, Gina S.; Shea, Steven; Barr, R. Graham

    2015-01-01

    Background Whereas low lung function is known to predict mortality in the general population, the prognostic significance of emphysema on computed tomography (CT) in persons without chronic obstructive pulmonary disease (COPD) remains uncertain. Objective To determine whether greater emphysema-like lung on CT is associated with all-cause mortality among persons without airflow obstruction or COPD in the general population. Design Prospective cohort study. Setting Population-based, multiethnic sample from 6 US communities. Participants 2965 participants ages 45-84 years without airflow obstruction on spirometry. Measurements Emphysema-like lung was defined on cardiac CT as the number of lung voxels less than -950 Hounsfield Units, and was adjusted for the number of total imaged lung voxels. Results Among 2965 participants, 50.9% of whom never smoked, there were 186 deaths over a median of 6.2 years. Greater emphysema-like lung was independently associated with increased mortality (adjusted hazard ratio [HR]1.14 per one-half of the interquartile range, 95% CI 1.04-1.24, P=0.004), adjusting for potential confounders including cardiovascular risk factors and the forced expiratory volume in one second. Generalized additive models supported a linear association between emphysema-like lung and mortality without evidence for a threshold. The association was of greatest magnitude among smokers, although multiplicative interaction terms did not support effect modification by smoking status. Limitations Cardiac CT scans did not include lung apices. The number of deaths was limited among subgroup analyses. Conclusions Emphysema-like lung on CT was associated with all-cause mortality among persons without airflow obstruction or COPD in a general population sample, particularly among smokers. Recognition of the independent prognostic significance of emphysema on CT among patients without COPD on spirometry is warranted. Primary Funding Source NIH/NHLBI. PMID:25506855

  3. High strain rate behaviour of polypropylene microfoams

    Science.gov (United States)

    Gómez-del Río, T.; Garrido, M. A.; Rodríguez, J.; Arencón, D.; Martínez, A. B.

    2012-08-01

    Microcellular materials such as polypropylene foams are often used in protective applications and passive safety for packaging (electronic components, aeronautical structures, food, etc.) or personal safety (helmets, knee-pads, etc.). In such applications the foams which are used are often designed to absorb the maximum energy and are generally subjected to severe loadings involving high strain rates. The manufacture process to obtain polymeric microcellular foams is based on the polymer saturation with a supercritical gas, at high temperature and pressure. This method presents several advantages over the conventional injection moulding techniques which make it industrially feasible. However, the effect of processing conditions such as blowing agent, concentration and microfoaming time and/or temperature on the microstructure of the resulting microcellular polymer (density, cell size and geometry) is not yet set up. The compressive mechanical behaviour of several microcellular polypropylene foams has been investigated over a wide range of strain rates (0.001 to 3000 s-1) in order to show the effects of the processing parameters and strain rate on the mechanical properties. High strain rate tests were performed using a Split Hopkinson Pressure Bar apparatus (SHPB). Polypropylene and polyethylene-ethylene block copolymer foams of various densities were considered.

  4. Air-cooled volcanoes ? New insights on convective airflow process within Miyakejima and Piton de la Fournaise volcanoes

    Science.gov (United States)

    Antoine, R.; Geshi, N.; Kurita, K.; Aoki, Y.; Ichihara, M.; Staudacher, T.; Bachelery, P.

    2012-04-01

    Subsurface airflow in the unsaturated zone of the soil has been extensively investigated in a variety of disciplines such as mining, nuclear waste or agriculture science. In volcanology, the recent discovery of subsurface airflow close to the terminal cone of Piton de La Fournaise volcano (La Réunion Island, France) provides for the first time insights into the convective behavior of air within the unsaturated layer [1]. The characteristics of the aerothermal system, its occurrence in other volcanoes, its ability to transport heat during quiescent periods and the perturbation of this system before eruptions are the key questions we want to address following this discovery. In this study, we present observations of subsurface convective airflow within opened fractures located at the summit of Miyakejima and Piton de la Fournaise volcanoes from anemometric and temperature data. Two anemometers and thermocouples were placed at the surface and at the center of the fracture at two-meter depth during a diurnal cycle. Six thermocouples also measured the temperature at 1 meter-depth, on a profile set perpendicularly to the fracture. Finally, a thermal camera was used to make punctual measurements of the surface temperature of the fracture. At Miyakejima, two surveys were realized in winter 2010 and summer 2011. During the winter, mild air exit was detected from the fracture with a central vertical velocity of 20 to 50 cm/s. The temperature of the site was constant during the diurnal cycle (~ 22°C), leading to a maximum temperature contrast of 15°C between the fracture and the atmosphere just before sunrise. During summer, a different hydrodynamic behavior was observed: Air inflow was detected during the whole diurnal cycle with a mean velocity of 20 cm/s. The temperature of the fracture followed the temperature of the atmosphere at 2 meters-depth. In the case of Piton de la Fournaise volcano, the same convective behavior was observed at two different fractures during

  5. Temporal dynamics of high repetition rate pulsed single longitudinal ...

    Indian Academy of Sciences (India)

    ing (GIG) cavity, single-mode dye laser pumped by high repetition rate ... in a high loss cavity, a detailed theoretical study and optimization of cavity ..... rate for high conversion efficiency and longer pulse width of the single-mode dye laser.

  6. High-Speed RaPToRS

    Science.gov (United States)

    Henchen, Robert; Esham, Benjamin; Becker, William; Pogozelski, Edward; Padalino, Stephen; Sangster, Thomas; Glebov, Vladimir

    2008-11-01

    The High-Speed Rapid Pneumatic Transport of Radioactive Samples (HS-RaPToRS) system, designed to quickly and safely move radioactive materials, was assembled and tested at the Mercury facility of the Naval Research Laboratory (NRL) in Washington D.C. A sample, which is placed inside a four-inch-diameter carrier, is activated before being transported through a PVC tube via airflow. The carrier travels from the reaction chamber to the end station where it pneumatically brakes prior to the gate. A magnetic latch releases the gate when the carrier arrives and comes to rest. The airflow, optical carrier-monitoring devices, and end gate are controlled manually or automatically with LabView software. The installation and testing of the RaPToRS system at NRL was successfully completed with transport times of less than 3 seconds. The speed of the carrier averaged 16 m/s. Prospective facilities for similar systems include the Laboratory for Laser Energetics and the National Ignition Facility.

  7. A digital approach for real time high-rate high-resolution radiation measurements

    International Nuclear Information System (INIS)

    Gerardi, G.; Abbene, L.

    2014-01-01

    Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted through both theoretical and experimental approaches. To strengthen our approach, the implementation of the method on a real-time system together with some experimental results are presented. X-ray spectra measurements with a semiconductor detector are performed both at low and high photon counting rates (up to 1.1 Mcps)

  8. A digital approach for real time high-rate high-resolution radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, G.; Abbene, L., E-mail: leonardo.abbene@unipa.it

    2014-12-21

    Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted through both theoretical and experimental approaches. To strengthen our approach, the implementation of the method on a real-time system together with some experimental results are presented. X-ray spectra measurements with a semiconductor detector are performed both at low and high photon counting rates (up to 1.1 Mcps)

  9. High-rate performance of muon drift tube detectors

    International Nuclear Information System (INIS)

    Schwegler, Philipp

    2014-01-01

    The Large Hadron Collider (LHC) at the European Centre for Particle Physics, CERN, collides protons with an unprecedentedly high centre-of-mass energy and luminosity. The collision products are recorded and analysed by four big experiments, one of which is the ATLAS detector. In parallel with the first LHC run from 2009 to 2012, which culminated in the discovery of the last missing particle of the Standard Model of particle physics, the Higgs boson, planning of upgrades of the LHC for higher instantaneous luminosities (HL-LHC) is already progressing. The high instantaneous luminosity of the LHC puts high demands on the detectors with respect to radiation hardness and rate capability which are further increased with the luminosity upgrade. In this thesis, the limitations of the Muon Drift Tube (MDT) chambers of the ATLAS Muon Spectrometer at the high background counting rates at the LHC and performance of new small diameter muon drift tube (sMDT) detectors at the even higher background rates at HL-LHC are studied. The resolution and efficiency of sMDT chambers at high γ-ray and proton irradiation rates well beyond the ones expected at HL-LHC have been measured and the irradiation effects understood using detailed simulations. The sMDT chambers offer an about an order of magnitude better rate capability and are an ideal replacement for the MDT chambers because of compatibility of services and read-out. The limitations of the sMDT chambers are now in the read-out electronics, taken from the MDT chambers, to which improvements for even higher rate capability are proposed.

  10. Solid state pump lasers with high power and high repetition rate

    International Nuclear Information System (INIS)

    Oba, Masaki; Kato, Masaaki; Arisawa, Takashi

    1995-01-01

    We built a laser diode pumped solid state green laser (LDPSSGL) rated at high repetition rate. Two laser heads are placed in one cavity with a rotator in between to design to avoid thermal lensing and thermal birefringence effect. Although average green laser power higher than 10 W was obtained at 1 kHz repetition rate with pulse width of 20-30 nsec, the beam quality was so much deteriorated that energy efficiency was as low as 2 %. Learning from this experience that high power oscillator causes a lot of thermal distortion not only in the laser rod but also in the Q-switch device, we proceeded to built a oscillator/amplifier system. A low power oscillator has a slab type crystal in the cavity. As a result spatial distribution of laser power was extremely improved. As we expect that the high repetition rate solid state laser should be CW operated Q-switch type laser from the view point of lifetime of diode lasers, a conventional arc lamp pumped CW Q-switch green YAG laser of which the repetition rate is changeable from 1 kHz to 5 kHz and the pulse width is 250-570 nsec was also tested to obtain pumping characteristics of a dye laser as a function of power, pulse width etc., and dye laser pulse width of 100-130 nsec were obtained. (author)

  11. Semi-solid electrodes having high rate capability

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Yet-Ming; Duduta, Mihai; Holman, Richard; Limthongkul, Pimpa; Tan, Taison

    2017-11-28

    Embodiments described herein relate generally to electrochemical cells having high rate capability, and more particularly to devices, systems and methods of producing high capacity and high rate capability batteries having relatively thick semi-solid electrodes. In some embodiments, an electrochemical cell includes an anode and a semi-solid cathode. The semi-solid cathode includes a suspension of an active material of about 35% to about 75% by volume of an active material and about 0.5% to about 8% by volume of a conductive material in a non-aqueous liquid electrolyte. An ion-permeable membrane is disposed between the anode and the semi-solid cathode. The semi-solid cathode has a thickness of about 250 .mu.m to about 2,000 .mu.m, and the electrochemical cell has an area specific capacity of at least about 7 mAh/cm.sup.2 at a C-rate of C/4. In some embodiments, the semi-solid cathode slurry has a mixing index of at least about 0.9.

  12. High resolution gamma-ray spectroscopy at high count rates with a prototype High Purity Germanium detector

    Science.gov (United States)

    Cooper, R. J.; Amman, M.; Vetter, K.

    2018-04-01

    High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.

  13. Natural ventilation for reducing airborne infection in hospitals

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Hua [School of Energy and Environment, Southeast University, Nanjing (China); Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong (China); Li, Yuguo; Ching, W.H.; Sun, H.Q. [Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong (China); Seto, W.H.; Ching, Patricia [Department of Microbiology, Queen Mary Hospital, Hong Kong (China)

    2010-03-15

    High ventilation rate is shown to be effective for reducing cross-infection risk of airborne diseases in hospitals and isolation rooms. Natural ventilation can deliver much higher ventilation rate than mechanical ventilation in an energy-efficient manner. This paper reports a field measurement of naturally ventilated hospital wards in Hong Kong and presents a possibility of using natural ventilation for infection control in hospital wards. Our measurements showed that natural ventilation could achieve high ventilation rates especially when both the windows and the doors were open in a ward. The highest ventilation rate recorded in our study was 69.0 ACH. The airflow pattern and the airflow direction were found to be unstable in some measurements with large openings. Mechanical fans were installed in a ward window to create a negative pressure difference. Measurements showed that the negative pressure difference was negligible with large openings but the overall airflow was controlled in the expected direction. When all the openings were closed and the exhaust fans were turned on, a reasonable negative pressure was created although the air temperature was uncontrolled. The high ventilation rate provided by natural ventilation can reduce cross-infection of airborne diseases, and thus it is recommended for consideration of use in appropriate hospital wards for infection control. Our results also demonstrated a possibility of converting an existing ward using natural ventilation to a temporary isolation room through installing mechanical exhaust fans. (author)

  14. Diagnostic Instability and Reversals of Chronic Obstructive Pulmonary Disease Diagnosis in Individuals with Mild to Moderate Airflow Obstruction.

    Science.gov (United States)

    Aaron, Shawn D; Tan, Wan C; Bourbeau, Jean; Sin, Don D; Loves, Robyn H; MacNeil, Jenna; Whitmore, George A

    2017-08-01

    Chronic obstructive pulmonary disease (COPD) is a chronic, progressive disease, and reversal of COPD diagnosis is thought to be uncommon. To determine whether a spirometric diagnosis of mild or moderate COPD is subject to variability and potential error. We examined two prospective cohort studies that enrolled subjects with mild to moderate post-bronchodilator airflow obstruction. The Lung Health Study (n = 5,861 subjects; study duration, 5 yr) and the Canadian Cohort of Obstructive Lung Disease (CanCOLD) study (n = 1,551 subjects; study duration, 4 yr) were examined to determine frequencies of (1) diagnostic instability, represented by how often patients initially met criteria for a spirometric diagnosis of COPD but then crossed the diagnostic threshold to normal and then crossed back to COPD over a series of annual visits, or vice versa; and (2) diagnostic reversals, defined as how often an individual's COPD diagnosis at the study outset reversed to normal by the end of the study. Diagnostic instability was common and occurred in 19.5% of the Lung Health Study subjects and 6.4% of the CanCOLD subjects. Diagnostic reversals of COPD from the beginning to the end of the study period occurred in 12.6% and 27.2% of subjects in the Lung Health Study and CanCOLD study, respectively. The risk of diagnostic instability was greatest for subjects whose baseline FEV 1 /FVC value was closest to the diagnostic threshold, and the risk of diagnostic reversal was greatest for subjects who quit smoking during the study. A single post-bronchodilator spirometric assessment may not be reliable for diagnosing COPD in patients with mild to moderate airflow obstruction at baseline.

  15. Effects of blood lead levels on airflow limitations in Korean adults: Findings from the 5th KNHNES 2011

    International Nuclear Information System (INIS)

    Chung, Hye Kyung; Chang, Yoon Soo; Ahn, Chul Woo

    2015-01-01

    This study aimed to examine whether blood levels of heavy metals, such as lead, mercury and cadmium, are related with pulmonary function in Korean adults. This investigation included 870 Korean adults (≥40 years) who received pulmonary function testing in the Korea National Health and Nutrition Examination Survey (KNHANES) V-2, 2011. Data of blood levels of heavy metals, pulmonary function tests and anthropometric measurements were acquired. Blood lead levels showed inverse correlations with the FEV 1 /FVC ratio before (r=−0.276, p<0.001) and after adjustment of multiple compounding factors (r=−0.115, p=0.001). A logistic multiple regression analysis revealed that blood lead levels were a significant influencing factor for the FEV 1 /FVC ratio (β=−0.017, p=0.001, adjusted R 2 =0.267). The odds ratios (ORs) for the FEV 1 /FVC ratio were significantly lower in the highest tertile group of the blood lead levels than in the lowest tertile group in Model 1 (OR=0.007, 95% CI=0.000−0.329) and Model 2 (OR=0.006, 95% CI=0.000−0.286). These findings imply that environmental exposure to lead might be an important factor that may cause airflow limitations in Korean adults. - Highlights: • Blood lead levels showed inverse correlations with the FEV 1 /FVC ratio. • Blood lead level was a significant influencing factor for the FEV 1 /FVC ratio. • ORs for FEV 1 /FVC were lower in the highest blood lead group than in the lowest group. • Environmental exposure to lead might be an important factor for airflow limitations

  16. High strain rate behaviour of polypropylene microfoams

    Directory of Open Access Journals (Sweden)

    Martínez A.B.

    2012-08-01

    Full Text Available Microcellular materials such as polypropylene foams are often used in protective applications and passive safety for packaging (electronic components, aeronautical structures, food, etc. or personal safety (helmets, knee-pads, etc.. In such applications the foams which are used are often designed to absorb the maximum energy and are generally subjected to severe loadings involving high strain rates. The manufacture process to obtain polymeric microcellular foams is based on the polymer saturation with a supercritical gas, at high temperature and pressure. This method presents several advantages over the conventional injection moulding techniques which make it industrially feasible. However, the effect of processing conditions such as blowing agent, concentration and microfoaming time and/or temperature on the microstructure of the resulting microcellular polymer (density, cell size and geometry is not yet set up. The compressive mechanical behaviour of several microcellular polypropylene foams has been investigated over a wide range of strain rates (0.001 to 3000 s−1 in order to show the effects of the processing parameters and strain rate on the mechanical properties. High strain rate tests were performed using a Split Hopkinson Pressure Bar apparatus (SHPB. Polypropylene and polyethylene-ethylene block copolymer foams of various densities were considered.

  17. Particle deposition on face-up flat plates in parallel airflow under the combined influences of thermophoresis and electrophoresis

    International Nuclear Information System (INIS)

    Lee, Handol; Yook, Sejin; Han, Seogyoung

    2012-01-01

    The deposition velocity is used to assess the degree of particulate contamination of wafers or photomasks. A numerical model was developed to predict the deposition velocity under the combined influences of thermophoresis and electrophoresis. The deposition velocity onto a face-up flat plate in parallel airflow was simulated by varying the temperature difference between the plate's surface and ambient air or by changing the strength of the electric field established above the plate. Both attraction and repulsion by thermophoresis or electrophoresis were considered. When the plate's surface was colder than ambient air, the surface of the face-up plate could be at risk of contamination by charged particles even with a repulsive applied electric force. When the temperature of the plate's surface was higher than the ambient temperature, the degree of particulate contamination on the surface of the face-up plate could be remarkably reduced in the presence of an electric field. The effect of repulsive thermophoresis, however, is expected to be reduced for very fine particles of high electric mobility or for micrometer-sized particles with large gravitational settling speed when the charged particles are influenced by an attractive electric force.

  18. Performance assessment of U.S. residential cooking exhaust hoods.

    Science.gov (United States)

    Delp, William W; Singer, Brett C

    2012-06-05

    This study assessed the performance of seven new residential cooking exhaust hoods representing common U.S. designs. Laboratory tests were conducted to determine fan curves relating airflow to duct static pressure, sound levels, and exhaust gas capture efficiency for front and back cooktop burners and the oven. Airflow rate sensitivity to duct flow resistance was higher for axial fan devices than for centrifugal fan devices. Pollutant capture efficiency (CE) ranged from 98%, varying across hoods and with airflow and burner position for each hood. CE was higher for back burners relative to front burners, presumably because most hoods covered only part of the front burners. Open hoods had higher CE than those with grease screen and metal-covered bottoms. The device with the highest CE--exceeding 80% for oven and front burners--had a large, open hood that covered most of the front burners. The airflow rate for this hood surpassed the industry-recommended level of 118 L·s(-1) (250 cfm) and produced sound levels too high for normal conversation. For hoods meeting the sound and fan efficacy criteria for Energy Star, CE was <30% for front and oven burners.

  19. The american high school graduation rate : trends and levels

    OpenAIRE

    Heckman, James J.; LaFontaine, Paul A.

    2008-01-01

    This paper uses multiple data sources and a unified methodology to estimate the trends and levels of the U.S. high school graduation rate. Correcting for important biases that plague previous calculations, we establish that (a) the true high school graduation rate is substantially lower than the official rate issued by the National Center for Educational Statistics; (b) it has been declining over the past 40 years; (c) majority/minority graduation rate differentials are substantial and have n...

  20. Surgical clothing systems in laminar airflow operating room: a numerical assessment.

    Science.gov (United States)

    Sadrizadeh, Sasan; Holmberg, Sture

    2014-01-01

    This study compared two different laminar airflow distribution strategies - horizontal and vertical - and investigated the effectiveness of both ventilation systems in terms of reducing the sedimentation and distribution of bacteria-carrying particles. Three different staff clothing systems, which resulted in source strengths of 1.5, 4 and 5 CFU/s per person, were considered. The exploration was conducted numerically using a computational fluid dynamics technique. Active and passive air sampling methods were simulated in addition to recovery tests, and the results were compared. Model validation was performed through comparisons with measurement data from the published literature. The recovery test yielded a value of 8.1 min for the horizontal ventilation scenario and 11.9 min for the vertical ventilation system. Fewer particles were captured by the slit sampler and in sedimentation areas with the horizontal ventilation system. The simulated results revealed that under identical conditions in the examined operating room, the horizontal laminar ventilation system performed better than the vertical option. The internal constellation of lamps, the surgical team and objects could have a serious effect on the movement of infectious particles and therefore on postoperative surgical site infections. Copyright © 2014 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  1. Low dose rate and high dose rate intracavitary treatment for cervical cancer

    International Nuclear Information System (INIS)

    Hareyama, Masato; Oouchi, Atsushi; Shidou, Mitsuo

    1997-01-01

    From 1984 through 1993, 144 previous untreated patients with carcinoma of uterine cervix were treated with either low dose rate 137 Cs therapy (LDR) or high dose rate 60 Co therapy (HDR). The local failure rates for more than 2-years for the primary lesions were 11.8% (8 of 63 patients) for LDR and 18.0% (11 of 61 patients). Rectal complication rates were significantly lower for HDR versus LDR (14.3% VS. 32.8%. p<0.01). Also, bladder complication rates were significantly lower for HDR versus LDR (0% VS. 10.4%, p<0.005). Treatment results in term of local control were equivalent for HDR and LDR treatment. However, the incidence of complications was higher for the LDR group than for the HDR group. (author)

  2. Transistor reset preamplifier for high-rate high-resolution spectroscopy

    International Nuclear Information System (INIS)

    Landis, D.A.; Cork, C.P.; Madden, N.W.; Goulding, F.S.

    1981-10-01

    Pulsed transistor reset of high resolution charge sensitive preamplifiers used in cooled semiconductor spectrometers can sometimes have an advantage over pulsed light reset systems. Several versions of transistor reset spectrometers using both silicon and germanium detectors have been built. This paper discusses the advantages of the transistor reset system and illustrates several configurations of the packages used for the FET and reset transistor. It also describes the preamplifer circuit and shows the performance of the spectrometer at high rates

  3. Lithium thionyl chloride high rate discharge

    Science.gov (United States)

    Klinedinst, K. A.

    1980-04-01

    Improvements in high rate lithium thionyl chloride power technology achieved by varying the electrolyte composition, operating temperature, cathode design, and cathode composition are discussed. Discharge capacities are plotted as a function of current density, cell voltage, and temperature.

  4. High frame rate synthetic aperture duplex imaging

    DEFF Research Database (Denmark)

    Stuart, Matthias Bo; Tomov, Borislav Gueorguiev; Pihl, Michael Johannes

    2013-01-01

    aperture flow imaging as demonstrated in this paper. Synthetic aperture, directional beamforming, and cross-correlation are used to produce B-mode and vector velocity images at high frame rates. The frame rate equals the effective pulse repetition frequency of each imaging mode. Emissions for making the B...... estimation is −1.8% and the relative standard deviation 5.4%. The approach can thus estimate both high and low velocities with equal accuracy and thereby makes it possible to present vector flow images with a high dynamic range. Measurements are made using the SARUS research scanner, a linear array......Conventional color flow images are limited in velocity range and can either show the high velocities in systole or be optimized for the lower diastolic velocities. The full dynamics of the flow is, thus, hard to visualize. The dynamic range can be significantly increased by employing synthetic...

  5. High-Rate Performance of Muon Drift Tube Detectors

    CERN Document Server

    Schwegler, Philipp

    The Large Hadron Collider (LHC) at the European Centre for Particle Physics, CERN, collides protons with an unprecedentedly high centre-of-mass energy and luminosity. The collision products are recorded and analysed by four big experiments, one of which is the ATLAS detector. In parallel with the first LHC run from 2009 to 2012, which culminated in the discovery of the last missing particle of the Standard Model of particle physics, the Higgs boson, planning of upgrades of the LHC for higher instantaneous luminosities (HL-LHC) is already progressing. The high instantaneous luminosity of the LHC puts high demands on the detectors with respect to radiation hardness and rate capability which are further increased with the luminosity upgrade. In this thesis, the limitations of the Muon Drift Tube (MDT) chambers of the ATLAS Muon Spectrometer at the high background counting rates at the LHC and performance of new small diameter muon drift tube (sMDT) detectors at the even higher background rates at HL-LHC are stud...

  6. Fireball flickering: the case for indirect measurement of meteoroid rotation rates

    Science.gov (United States)

    Beech, Martin; Brown, Peter

    2000-08-01

    Data collected during the Meteorite Observation and Recovery Program (MORP) indicate that 4% of bright fireballs show a periodic variation or flickering in brightness. The observed flickering frequencies vary from a few Hz to as high as 500 Hz. We interpret the flickering phenomenon in terms of meteoroid rotation. The MORP data does not reveal any apparent correlation between the flickering frequency and the properties of the meteoroid or the atmospheric flow conditions under which ablation is taking place. It is argued that the most likely cause of the flickering phenomenon is the rotational modulation of the cross-section area presented by the meteoroid to the on-coming airflow. A study is made of the Peekskill fireball and it is concluded that the meteoroid was spun-up during its long flight through the Earth's atmosphere, and that its initial brake up was due to rotational bursting. We also argue that the Peekskill event provides the best observational evidence that the flickering phenomenon is truly related to the rotation rate of the impinging meteoroid. We find that the observed rotation rates of the MORP fireballs are clustered just below the allowed limit set by rotational bursting, but argue that this is due to an observational selection effect that mitigates against the detection of low-frequency flickering.

  7. High energy high repetition-rate thin-disk amplifier for OPCPA pumping

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael

    2013-08-15

    The development of a pump laser system for a high power and high repetition rate optical parametric chirped-pulse amplification (OPCPA) is presented in this thesis. The OPCPA system requires pump pulse energies in the range of tens of millijoules at high repetition rates with sub-picosecond pulse durations. This can be achieved to some extend with Innoslab amplifier technology. However, scaling to higher pulse energies at high repetition rates may be problematic. With the thin-disk amplifier presented in this thesis, output energies of 140 mJ at 100 kHz repetition rate could be achieved in burst-mode operation, which is a world record for this type of laser amplifier. Due to its material and spectral properties, ytterbium doped YAG (Yb:YAG) is used as a gain medium for the high power amplifier stages. The low quantum defect and the comparatively large emission bandwidth makes this material the choice for high power operation and sub-picosecond compressed pulse durations. The output beam profile as well as the shape of the output bursts is ideal to pump an OPCPA system. An OPCPA output energy in the millijoule range with repetition rates of 100 kHz to 1 MHz is needed to generate seed pulses for the FEL and for the application as pump-probe laser at the FEL facility. Since the development of this laser system needs to meet requirements set by the Free-Electron Laser in Hamburg (FLASH), the amplifier is conceived for burst-mode operation. The main requirement is a high intra-burst pulse repetition rate of more than 100 kHz and a uniform pulse train (burst) with equal properties for every pulse. The burst-mode is an operation mode where the laser never reaches a lasing equilibrium, which means that the behavior of the amplifier is similar to a switch-on of the laser system for every burst. This makes the development of the amplifier system difficult. Therefore, an analytical model has been developed to study the amplification process during the burst. This includes the

  8. High energy high repetition-rate thin-disk amplifier for OPCPA pumping

    International Nuclear Information System (INIS)

    Schulz, Michael

    2013-08-01

    The development of a pump laser system for a high power and high repetition rate optical parametric chirped-pulse amplification (OPCPA) is presented in this thesis. The OPCPA system requires pump pulse energies in the range of tens of millijoules at high repetition rates with sub-picosecond pulse durations. This can be achieved to some extend with Innoslab amplifier technology. However, scaling to higher pulse energies at high repetition rates may be problematic. With the thin-disk amplifier presented in this thesis, output energies of 140 mJ at 100 kHz repetition rate could be achieved in burst-mode operation, which is a world record for this type of laser amplifier. Due to its material and spectral properties, ytterbium doped YAG (Yb:YAG) is used as a gain medium for the high power amplifier stages. The low quantum defect and the comparatively large emission bandwidth makes this material the choice for high power operation and sub-picosecond compressed pulse durations. The output beam profile as well as the shape of the output bursts is ideal to pump an OPCPA system. An OPCPA output energy in the millijoule range with repetition rates of 100 kHz to 1 MHz is needed to generate seed pulses for the FEL and for the application as pump-probe laser at the FEL facility. Since the development of this laser system needs to meet requirements set by the Free-Electron Laser in Hamburg (FLASH), the amplifier is conceived for burst-mode operation. The main requirement is a high intra-burst pulse repetition rate of more than 100 kHz and a uniform pulse train (burst) with equal properties for every pulse. The burst-mode is an operation mode where the laser never reaches a lasing equilibrium, which means that the behavior of the amplifier is similar to a switch-on of the laser system for every burst. This makes the development of the amplifier system difficult. Therefore, an analytical model has been developed to study the amplification process during the burst. This includes the

  9. Circuit and interconnect design for high bit-rate applications

    NARCIS (Netherlands)

    Veenstra, H.

    2006-01-01

    This thesis presents circuit and interconnect design techniques and design flows that address the most difficult and ill-defined aspects of the design of ICs for high bit-rate applications. Bottlenecks in interconnect design, circuit design and on-chip signal distribution for high bit-rate

  10. Characteristics of mercury emission from linear type of spent fluorescent lamp.

    Science.gov (United States)

    Rhee, Seung-Whee; Choi, Hyo-Hyun; Park, Hun-Su

    2014-06-01

    In order to recycle the linear type of SFL (spent fluorescent lamp), mercury from SFL should be controlled to prevent leaking into the environment. For mercury emission from SFL, mercury concentration is estimated in the parts of SFL such as glass tube, phosphor powder, and base cap using the end-cutting unit. It is also evaluated mercury emission in the effluent gas in the end-cutting unit with changing flow rate. From the results of mercury emission from SFLs, phosphor powder has greater than 80% of mercury amount in SFL and about 15% of mercury amount contained in glass tube. The initial mercury concentration in vapor phase is almost decreased linearly with increasing airflow rate from 0.7 L/min to 1.3 L/min. It is desirable that airflow rate should be high until the concentration of mercury vapor will be stable because the stabilized concentration becomes to be low and the stabilized time goes to be short as increased airflow rate. From KET and TCLP results, finally, phosphor powder should be managed as a hazardous waste but base-cap and glass are not classified as hazardous wastes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. CO diffusing capacity in a general population sample: relationships with cigarette smoking and airflow obstruction.

    Science.gov (United States)

    Viegi, G; Paoletti, P; Carrozzi, L; Baldacci, S; Modena, P; Pedreschi, M; Di Pede, F; Mammini, U; Giuntini, C

    1993-01-01

    The single-breath carbon monoxide diffusing capacity (DLCOsb) was measured together with ventilatory lung function tests as part of a survey of a general population sample living in Northern Italy (n = 2,481). Based on answers to an interviewer-administered questionnaire, subjects free of respiratory symptoms or diseases were identified. Data from subjects who had never regularly smoked cigarettes were used to derive reference equations for the test indexes, and data from the remaining subjects who had smoked were used to derive regression equations incorporating a term expressing cigarette consumption (cube root of pack-years) and a term indicating current smoking decrement, in order to obtain expected DLCOsb percent predicted. Neither number of cigarettes smoked daily or duration of smoking, in smokers, nor duration of smoking or years since quitting smoking, in ex-smokers, entered significantly the multiple-regression model. The mean values of DLCOsb were only slightly affected by the increasing degree of airway obstruction. When subjects with confirmed asthma were analyzed, after stratifying for different levels of FEV1/FVC ratio, increased mean value of DLCOsb (over 100%) was found in those with an FEV1/FVC ratio between 75 and 65%. This cross-sectional analysis suggests that there is a decrease in DLCOsb with cumulative cigarette consumption even in healthy subjects. Further, it confirms the clinical observations of high DLCOsb values in asthmatic patients, at least in those with an initial degree of chronic airflow obstruction.

  12. High rate tests of the LHCb RICH Upgrade system

    CERN Multimedia

    Blago, Michele Piero

    2016-01-01

    One of the biggest challenges for the upgrade of the LHCb RICH detectors from 2020 is to readout the photon detectors at the full 40 MHz rate of the LHC proton-proton collisions. A test facility has been setup at CERN with the purpose to investigate the behaviour of the Multi Anode PMTs, which have been proposed for the upgrade, and their readout electronics at high trigger rates. The MaPMTs are illuminated with a monochromatic laser that can be triggered independently of the readout electronics. A first series of tests, including threshold scans, is performed at low trigger rates (20 kHz) for both the readout and the laser with the purpose to characterise the behaviour of the system under test. Then the trigger rate is increased in two separate steps. First the MaPMTs are exposed to high illumination by triggering the pulsed laser at a high (20 MHz) repetition rate while the DAQ is readout at the same low rate as before. In this way the performance of the MaPMTs and the attached electronics can be evaluated ...

  13. Experimental and Numerical Study on Effects of Airflow and Aqueous Ammonium Temperature on Ammonia Mass Transfer Coefficient

    DEFF Research Database (Denmark)

    Rong, Li; Nielsen, Peter V.; Zhang, Guoqiang

    2010-01-01

    greatly along the airflow direction on the emission surface. The average mass transfer coefficient increases with higher velocity and turbulence intensity. However, the mass transfer coefficient estimated by CFD simulation is consistently larger than the calculated one by the method using dissociation...... constant and Henry's constant models. In addition, the results show that the liquid-air temperature difference has little impact on the simulated mass transfer coefficient by CFD modeling, whereas the mass transfer coefficient increases with higher liquid temperature using the other method under...... the conditions that the liquid temperature is lower than the air temperature. Although there are differences of mass transfer coefficients between these two methods, the mass transfer coefficients determined by these two methods are significantly related....

  14. Corticosteroid therapy and airflow obstruction influence the bronchial microbiome, which is distinct from that of bronchoalveolar lavage in asthmatic airways

    Energy Technology Data Exchange (ETDEWEB)

    Denner, Darcy R.; Sangwan, Naseer; Becker, Julia B.; Hogarth, D. Kyle; Oldham, Justin; Castillo, Jamee; Sperling, Anne I.; Solway, Julian; Naureckas, Edward T.; Gilbert, Jack A.; White, Steven R.

    2016-05-01

    The lung has a diverse microbiome that is modest in biomass. This microbiome differs in asthmatic patients compared with control subjects, but the effects of clinical characteristics on the microbial community composition and structure are not clear. OBJECTIVES: We examined whether the composition and structure of the lower airway microbiome correlated with clinical characteristics of chronic persistent asthma, including airflow obstruction, use of corticosteroid medications, and presence of airway eosinophilia. METHODS: DNA was extracted from endobronchial brushings and bronchoalveolar lavage fluid collected from 39 asthmatic patients and 19 control subjects, along with negative control samples. 16S rRNA V4 amplicon sequencing was used to compare the relative abundance of bacterial genera with clinical characteristics. RESULTS: Differential feature selection analysis revealed significant differences in microbial diversity between brush and lavage samples from asthmatic patients and control subjects. Lactobacillus, Pseudomonas, and Rickettsia species were significantly enriched in samples from asthmatic patients, whereas Prevotella, Streptococcus, and Veillonella species were enriched in brush samples from control subjects. Generalized linear models on brush samples demonstrated oral corticosteroid use as an important factor affecting the relative abundance of the taxa that were significantly enriched in asthmatic patients. In addition, bacterial α-diversity in brush samples from asthmatic patients was correlated with FEV1 and the proportion of lavage eosinophils. CONCLUSION: The diversity and composition of the bronchial airway microbiome of asthmatic patients is distinct from that of nonasthmatic control subjects and influenced by worsening airflow obstruction and corticosteroid use. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  15. Intermittent Coffee Drying in Deep Bed with Pulsed Airflow Secado de Café en Lecho Fijo con Intermitencia Térmica y Flujo de Aire Pulsado

    Directory of Open Access Journals (Sweden)

    Héctor José Ciro Velásquez

    2011-12-01

    Full Text Available A dryer in deep bed without airflow reversal was adapted to work simultaneously with thermal intermittence and pulsed airflow in the drying of parchment coffee bean. The dryer was operated by cycles of thermal intermittence for a heating temperature of 55 °C and cooling of 40 and 25 °C. The results showed that the increase of temperature in the cycle of cooling tends to increase the water removal and that the increase of the number of air pulses without reversal of the direction of air flow causes an excessive moisture gradient within the batch. Moreover, the specific energy requirement of the dryer was from 15 to 25 MJ/kg, showing the best thermal performance for the condition in which the dryer was operate without pulsed airflow.Un secador de lecho fijo fue adaptado para trabajar de forma simultánea con intermitencia térmica y flujo de aire pulsado sin inversión de flujo de aire, en el secado de granos de café. El secador fue operado con ciclos de intermitencia térmica para una temperatura de calentamiento de 55 °C y enfriamiento de 40 y 25 °C. Los resultados mostraron que el aumento de temperatura en el ciclo de enfriamiento, tiende a incrementar la remoción de agua y que el aumento del número de pulsos de aire sin inversión del flujo de dirección del aire, ocasiona un secado deficiente debido al excesivo gradiente de humedad ocasionado en la capa de producto. Adicionalmente, se encontró que el consumo de energía específica del secador varió entre 15 y 25 MJ/kg de agua evaporada, siendo el mejor rendimiento termo energético para la condición en la cual el secador fue operado sin flujo de aire pulsado.

  16. Application of Shark Skin Flow Control Techniques to Airflow

    Science.gov (United States)

    Morris, Jackson Alexander

    Due to millions of years of evolution, sharks have evolved to become quick and efficient ocean apex predators. Shark skin is made up of millions of microscopic scales, or denticles, that are approximately 0.2 mm in size. Scales located on the shark's body where separation control is paramount (such as behind the gills or the trailing edge of the pectoral fin) are capable of bristling. These scales are hypothesized to act as a flow control mechanism capable of being passively actuated by reversed flow. It is believed that shark scales are strategically sized to interact with the lower 5% of a boundary layer, where reversed flow occurs at the onset of boundary layer separation. Previous research has shown shark skin to be capable of controlling separation in water. This thesis aims to investigate the same passive flow control techniques in air. To investigate this phenomenon, several sets of microflaps were designed and manufactured with a 3D printer. The microflaps were designed in both 2D (rectangular) and 3D (mirroring shark scale geometry) variants. These microflaps were placed in a low-speed wind tunnel in the lower 5% of the boundary layer. Solid fences and a flat plate diffuser with suction were placed in the tunnel to create different separated flow regions. A hot film probe was used to measure velocity magnitude in the streamwise plane of the separated regions. The results showed that low-speed airflow is capable of bristling objects in the boundary layer. When placed in a region of reverse flow, the microflaps were passively actuated. Microflaps fluctuated between bristled and flat states in reverse flow regions located close to the reattachment zone.

  17. Ultra Fast, High Rep Rate, High Voltage Spark Gap Pulser

    Science.gov (United States)

    1995-07-01

    current rise time. The spark gap was designed to have a coaxial geometry reducing its inductance. Provisions were made to pass flowing gas between the...ULTRA FAST, HIGH REP RATE, HIGH VOLTAGE SPARK GAP PULSER Robert A. Pastore Jr., Lawrence E. Kingsley, Kevin Fonda, Erik Lenzing Electrophysics and...Modeling Branch AMSRL-PS-EA Tel.: (908)-532-0271 FAX: (908)-542-3348 U.S. Army Research Laboratory Physical Sciences Directorate Ft. Monmouth

  18. Spallation model for the high strain rates range

    Science.gov (United States)

    Dekel, E.; Eliezer, S.; Henis, Z.; Moshe, E.; Ludmirsky, A.; Goldberg, I. B.

    1998-11-01

    Measurements of the dynamic spall strength in aluminum and copper shocked by a high power laser to pressures of hundreds of kbars show a rapid increase in the spall strength with the strain rate at values of about 107 s-1. We suggest that this behavior is a result of a change in the spall mechanism. At low strain rates the spall is caused by the motion and coalescence of material's initial flaws. At high strain rates there is not enough time for the flaws to move and the spall is produced by the formation and coalescence of additional cavities where the interatomic forces become dominant. Material under tensile stress is in a metastable condition and cavities of a critical radius are formed in it due to thermal fluctuations. These cavities grow due to the tension. The total volume of the voids grow until the material disintegrates at the spall plane. Simplified calculations based on this model, describing the metal as a viscous liquid, give results in fairly good agreement with the experimental data and predict the increase in spall strength at high strain rates.

  19. The Effect of Minimum Wage Rates on High School Completion

    Science.gov (United States)

    Warren, John Robert; Hamrock, Caitlin

    2010-01-01

    Does increasing the minimum wage reduce the high school completion rate? Previous research has suffered from (1. narrow time horizons, (2. potentially inadequate measures of states' high school completion rates, and (3. potentially inadequate measures of minimum wage rates. Overcoming each of these limitations, we analyze the impact of changes in…

  20. HIGH-RATE ANAEROBIC TREATMENT OF ALCOHOLIC WASTEWATERS

    Directory of Open Access Journals (Sweden)

    Florencio L.

    1997-01-01

    Full Text Available Modern high-rate anaerobic wastewater treatment processes are rapidly becoming popular for industrial wastewater treatment. However, until recently stable process conditions could not be guaranteed for alcoholic wastewaters containing higher concentrations of methanol. Although methanol can be directly converted into methane by methanogens, under specific conditions it can also be converted into acetate and butyrate by acetogens. The accumulation of volatile fatty acids can lead to reactor instability in a weakly buffered reactor. Since this process was insufficiently understood, the application of high-rate anaerobic reactors was highly questionable. This research investigated the environmental factors that are of importance in the predominance of methylotrophic methanogens over acetogens in a natural mixed culture during anaerobic wastewater treatment in upflow anaerobic sludge bed reactors. Technological and microbiological aspects were investigated. Additionally, the route by which methanol is converted into methane is also presented

  1. Baltimore District Tackles High Suspension Rates

    Science.gov (United States)

    Maxwell, Lesli A.

    2007-01-01

    This article reports on how the Baltimore District tackles its high suspension rates. Driven by an increasing belief that zero-tolerance disciplinary policies are ineffective, more educators are embracing strategies that do not exclude misbehaving students from school for offenses such as insubordination, disrespect, cutting class, tardiness, and…

  2. Sand Transport under Highly Turbulent Airflow on a Beach Surface

    Science.gov (United States)

    Baas, A. C. W.; Jackson, D. W. T.; Cooper, J. A. G.; Lynch, K.; Delgado-Fernandez, I.; Beyers, J. H. M.

    2012-04-01

    The past decade has seen a growing body of research on the relation between turbulence in the wind and the resultant transport of sediment over active sand surfaces. Widespread use of sonic anemometry and high-frequency sand transport sensors and traps have facilitated recent field studies over dunes and beach surfaces, to move beyond monitoring of mean wind speed and bulk transport to more detailed measurements at much higher spatio-temporal resolutions. In this paper we present results of a field study conducted in the recirculation flow and re-attachment zone on a beach behind a foredune at Magilligan Strand, Northern Ireland. The offshore winds over the foredune at this site are associated with flow separation and reversal located over the beach surface in the lee of the dune row, often strong enough to induce sand transport toward the toe of the foredune ('against' the overall offshore flow). The re-attachment and recirculation zone are associated with strongly turbulent fluid flow and complex streamlines that do not follow the underlying topography. High frequency (25 Hz) wind and sand transport data were collected at a grid of point locations distributed over the beach surface between 35 m to 55 m distance from the 10 m high dune crest, using ultrasonic anemometers at 0.5 m height and co-located load cell traps and Safires at the bed surface. The wind data are used to investigate the role of Reynolds shear stresses and quadrant analysis techniques for identifying burst-sweep events in relation to sand transport events. This includes an assessment of the issues involved with data rotations for yaw, pitch, and roll corrections relative to complex flow streamlines, and the subsequently derived turbulence parameters based on fluctuating vector components (u', v', w'). Results illustrate how transport may exist under threshold mean velocities because of the role played by coherent flow structures, and the findings corroborate previous findings that shear velocity

  3. Cosmological Evolution of the Central Engine in High-Luminosity, High-Accretion Rate AGN

    Directory of Open Access Journals (Sweden)

    Matteo Guainazzi

    2014-12-01

    Full Text Available In this paper I discuss the status of observational studies aiming at probing the cosmological evolution of the central engine in high-luminosity, high-accretion rate Active Galactic Nuclei (AGN. X-ray spectroscopic surveys, supported by extensive multi-wavelength coverage, indicate a remarkable invariance of the accretion disk plus corona system, and of their coupling up to redshifts z≈6. Furthermore, hard X-ray (E >10 keV surveys show that nearby Seyfert Galaxies share the same central engine notwithstanding their optical classication. These results suggest that the high-luminosity, high accretion rate quasar phase of AGN evolution is homogeneous over cosmological times.

  4. High strain rate studies in rock

    International Nuclear Information System (INIS)

    Grady, D.

    1977-01-01

    Dynamic compression studies using high velocity impact are usually considered to involve a catastrophic process of indeterminate loading rate by which a material is brough to a shock compressed state. Although this is frequently the case, methods are also available to control the rate of strain during the shock compression process. One of the most accurate of these methods makes use of the anomalous nonlinear elastic property of glass to transform an initial shock or step wave input into a ramp wave of known amplitude and duration. Fused silica is the most carefully calibrated material for this purpose and, when placed between the test specimen and the impact projectile, can provide loading strain rates in the range of 10 4 /s to 10 6 /s for final stress states of approximately 3.9 GPa or less.Ramp wave compression experiments have been conducted on dolomite at strain rates of 3 x 10 4 /s. Both initial yielding and subsequent deformation at this strain rate agrees well with previous shock wave studies (epsilon-dotapprox.10 6 /s) and differs substantially from quasi-static measurements (epsilon-dotapprox.10 -4 /s). The ramp wave studies have also uncovered a pressure-induced phase transition in dolomite initiating at 4.0 GPa

  5. Buoyancy Driven Natural Ventilation through Horizontal Openings

    DEFF Research Database (Denmark)

    Heiselberg, Per

    2009-01-01

    An experimental study of the phenomenon of buoyancy driven natural ventilation through single-sided horizontal openings was performed in a full-scale laboratory test rig. The measurements were made for opening ratios L/D ranging from 0.027 to 4.455, where L and D are the length of the opening...... and the diameter of the opening, respectively. The basic nature of airflow through single-sided openings, including airflow rate, air velocity, temperature difference between the rooms and the dimensions of the horizontal openings, were measured. A bi-directional airflow rate was measured using the constant...... quite well with the Epstein's formula ratio are presented. In some cases the measured airflow rates fit quite well with the Epstein's formula but in other cases the measured data show clear deviations from the Epstein's formula. Thus, revised formulas for natural ventilation are proposed....

  6. Does air gas aesthesiometry generate a true mechanical stimulus for corneal sensitivity measurement?

    Science.gov (United States)

    Nosch, Daniela S; Pult, Heiko; Albon, Julie; Purslow, Christine; Murphy, Paul J

    2018-03-01

    Belmonte Ocular Pain Meter (OPM) air jet aesthesiometry overcomes some of the limitations of the Cochet-Bonnet aesthesiometer. However, for true mechanical corneal sensitivity measurement, the airflow stimulus temperature of the aesthesiometer must equal ocular surface temperature (OST), to avoid additional response from temperature-sensitive nerves. The aim of this study was to determine: (A) the stimulus temperature inducing no or least change in OST; and (B) to evaluate if OST remains unchanged with different stimulus durations and airflow rates. A total of 14 subjects (mean age 25.14 ± 2.18 years; seven women) participated in this clinical cohort study: (A) OST was recorded using an infrared camera (FLIR A310) during the presentation of airflow stimuli, at five temperatures, ambient temperature (AT) +5°C, +10°C, +15°C, +20°C and +30°C, using the OPM aesthesiometer (duration three seconds; over a four millimetre distance; airflow rate 60 ml/min); and (B) OST measurements were repeated with two stimulus temperatures (AT +10°C and +15°C) while varying stimulus durations (three seconds and five seconds) and airflow rates (30, 60, 80 and 100 ml/min). Inclusion criteria were age measures (analysis of variance) and appropriate post-hoc t-tests were applied. (A) Stimulus temperatures of AT +10°C and +15°C induced the least changes in OST (-0.20 ± 0.13°C and 0.08 ± 0.05°C). (B) OST changes were statistically significant with both stimulus temperatures and increased with increasing airflow rates (p air stimulus of the Belmonte OPM because its air jet stimulus with mechanical setting is likely to have a thermal component. Appropriate stimulus selection for an air jet aesthesiometer must incorporate stimulus temperature control that can vary with stimulus duration and airflow rate. © 2017 Optometry Australia.

  7. Stretching of red blood cells at high strain rates

    Science.gov (United States)

    Mancuso, J. E.; Ristenpart, W. D.

    2017-10-01

    Most work on the mechanical behavior of red blood cells (RBCs) in flow has focused on simple shear flows. Relatively little work has examined RBC deformations in the physiologically important extensional flow that occurs at the entrance to a constriction. In particular, previous work suggests that RBCs rapidly stretch out and then retract upon entering the constriction, but to date no model predicts this behavior for the extremely high strain rates typically experienced there. In this Rapid Communication, we use high speed video to perform systematic measurements of the dynamic stretching behavior of RBCs as they enter a microfluidic constriction. We demonstrate that both the Kelvin-Voigt and Skalak viscoelastic models capture the observed stretching dynamics, up to strain rates as high as 2000 s-1. The results indicate that the effective elastic modulus of the RBC membrane at these strain rates is an order of magnitude larger than moduli measured by micropipette aspiration or other low strain rate techniques.

  8. High-power pre-chirp managed amplification of femtosecond pulses at high repetition rates

    International Nuclear Information System (INIS)

    Liu, Yang; Li, Wenxue; Zhao, Jian; Bai, Dongbi; Luo, Daping; Zeng, Heping

    2015-01-01

    Femtosecond pulses at 250 MHz repetition rate from a mode-locked fiber laser are amplified to high power in a pre-chirp managed amplifier. The experimental strategy offers a potential towards high-power ultrashort laser pulses at high repetition rates. By investigating the laser pulse evolution in the amplification processes, we show that self-similar evolution, finite gain bandwidth and mode instabilities determine pulse characteristics in different regimes. Further average power scaling is limited by the mode instabilities. Nevertheless, this laser system enables us to achieve sub-50 fs pulses with an average power of 93 W. (letter)

  9. High-frame-rate digital radiographic videography

    Science.gov (United States)

    King, Nicholas S. P.; Cverna, Frank H.; Albright, Kevin L.; Jaramillo, Steven A.; Yates, George J.; McDonald, Thomas E.; Flynn, Michael J.; Tashman, Scott

    1994-10-01

    High speed x-ray imaging can be an important tool for observing internal processes in a wide range of applications. In this paper we describe preliminary implementation of a system having the eventual goal of observing the internal dynamics of bone and joint reactions during loading. Two Los Alamos National Laboratory (LANL) gated and image intensified camera systems were used to record images from an x-ray image convertor tube to demonstrate the potential of high frame-rate digital radiographic videography in the analysis of bone and joint dynamics of the human body. Preliminary experiments were done at LANL to test the systems. Initial high frame-rate imaging (from 500 to 1000 frames/s) of a swinging pendulum mounted to the face of an X-ray image convertor tube demonstrated high contrast response and baseline sensitivity. The systems were then evaluated at the Motion Analysis Laboratory of Henry Ford Health Systems Bone and Joint Center. Imaging of a 9 inch acrylic disk with embedded lead markers rotating at approximately 1000 RPM, demonstrated the system response to a high velocity/high contrast target. By gating the P-20 phosphor image from the X-ray image convertor with a second image intensifier (II) and using a 100 microsecond wide optical gate through the second II, enough prompt light decay from the x-ray image convertor phosphor had taken place to achieve reduction of most of the motion blurring. Measurement of the marker velocity was made by using video frames acquired at 500 frames/s. The data obtained from both experiments successfully demonstrated the feasibility of the technique. Several key areas for improvement are discussed along with salient test results and experiment details.

  10. Prevalence and determinants of airflow limitation in urban and rural children exposed to cooking fuels in South-East Nigeria.

    Science.gov (United States)

    Oguonu, Tagbo; Obumneme-Anyim, Ijeoma N; Eze, Joy N; Ayuk, Adaeze C; Okoli, Chinyere V; Ndu, Ikenna K

    2018-03-15

    Background Biofuels and other cooking fuels are used in households in low- and middle-income countries. Aim To investigate the impact of cooking fuels on lung function in children in urban and rural households in South-East Nigeria. Methods The multi-stage sampling method was used to enroll children exposed to cooking fuel in the communities. Lung function values FEV1, FVC and the FEV1/FVC ratio, were measured with ndd EasyOne R spirometer. Airflow limitation was determined with FEV1/FVC Z-score values at -1.64 as the lower limit of normal (LLN5). The Global Lung Function Initiative 2012 software was used to calculate the lung function indices. Results The median age (range) of the 912 children enrolled was 10.6 years (6-18). Altogether, 468 (51.6%) children lived in rural areas. Seven hundred and thirty-seven (80.7%) were directly exposed to cooking fuels (418/737, 56.5% in rural areas). Wood and kerosene were the dominant fuels in rural and urban households. The respective mean Z-scores of the exposed children in rural and urban were zFEV1 -0.62, FVC -0.21, FEV1/FVC -0.83 and zFEV1 -0.57, zFVC -0.14, FEV1/FVC -0.75. Few (5.2%, 38/737) of the children had airflow limitation. Most of them (60.5%, 25/38) lived in the rural community; the lowest FEV1/FVC Z-scores were those of exposed to a combination of fuels. Conclusion Exposure to cooking fuels affects lung function in children with airway limitation in a small proportion, Control measures are advocated to reduce the morbidity related to cooking fuels exposure.

  11. Improving Aviation Safety with information Visualization: A Flight Simulation Study

    Science.gov (United States)

    Aragon, Cecilia R.; Hearst, Marti

    2005-01-01

    Many aircraft accidents each year are caused by encounters with invisible airflow hazards. Recent advances in aviation sensor technology offer the potential for aircraft-based sensors that can gather large amounts of airflow velocity data in real-time. With this influx of data comes the need to study how best to present it to the pilot - a cognitively overloaded user focused on a primary task other than that of information visualization. In this paper, we present the results of a usability study of an airflow hazard visualization system that significantly reduced the crash rate among experienced helicopter pilots flying a high fidelity, aerodynamically realistic fixed-base rotorcraft flight simulator into hazardous conditions. We focus on one particular aviation application, but the results may be relevant to user interfaces in other operationally stressful environments.

  12. Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades

    CERN Document Server

    Bittner, Bernhard; Kortner, Oliver; Kroha, Hubert; Manfredini, Alessandro; Nowak, Sebastian; Ott, Sebastian; Richter, Robert; Schwegler, Philipp; Zanzi, Daniele; Biebel, Otmar; Hertenberger, Ralf; Ruschke, Alexander; Zibell, Andre

    2016-01-01

    The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking e?ciency and spatial resolution at high counting rates will be achieved with ...

  13. Cheetah: A high frame rate, high resolution SWIR image camera

    Science.gov (United States)

    Neys, Joel; Bentell, Jonas; O'Grady, Matt; Vermeiren, Jan; Colin, Thierry; Hooylaerts, Peter; Grietens, Bob

    2008-10-01

    A high resolution, high frame rate InGaAs based image sensor and associated camera has been developed. The sensor and the camera are capable of recording and delivering more than 1700 full 640x512pixel frames per second. The FPA utilizes a low lag CTIA current integrator in each pixel, enabling integration times shorter than one microsecond. On-chip logics allows for four different sub windows to be read out simultaneously at even higher rates. The spectral sensitivity of the FPA is situated in the SWIR range [0.9-1.7 μm] and can be further extended into the Visible and NIR range. The Cheetah camera has max 16 GB of on-board memory to store the acquired images and transfer the data over a Gigabit Ethernet connection to the PC. The camera is also equipped with a full CameralinkTM interface to directly stream the data to a frame grabber or dedicated image processing unit. The Cheetah camera is completely under software control.

  14. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  15. Thermal properties of highly structured composite and aluminium sheets in an aerodynamic tunnel

    Science.gov (United States)

    Kulhavy, Petr; Egert, Josef

    This article deals with the thermodynamic behaviour of heat shields - structured metal and composite plates. Experiments have been carried out in a wind tunnel with an additional heating, which simulates the heat source from engine or exhaust pipe and simultaneously the airflow generated during a car movement. The tested sheets with hexagonal structure were a standard commercial made of aluminium and a second manufactured by replication (lamination, diffusion) from glass fabric. The airflow in a parallel way along the sheets was analysed experimentally in order to determine the heat transfer efficiency between surfaces of sheets and surrounding airflow. The temperature on the sheets was chosen to observe the effects of different sheets material, various heat power and airflow velocity. During the experiment a thermal input below the sheets and airflow velocity through the tunnel have been changed. The thermal field distribution on the metal sheet is different than in case of composite sheet. For the composite material the thermal field distribution was more homogeneous. This article describe briefly also methods of obtaining real composite geometry based on scanned data and their reconstruction for using in some future numerical models.

  16. Thermal properties of highly structured composite and aluminium sheets in an aerodynamic tunnel

    Directory of Open Access Journals (Sweden)

    Kulhavy Petr

    2017-01-01

    Full Text Available This article deals with the thermodynamic behaviour of heat shields - structured metal and composite plates. Experiments have been carried out in a wind tunnel with an additional heating, which simulates the heat source from engine or exhaust pipe and simultaneously the airflow generated during a car movement. The tested sheets with hexagonal structure were a standard commercial made of aluminium and a second manufactured by replication (lamination, diffusion from glass fabric. The airflow in a parallel way along the sheets was analysed experimentally in order to determine the heat transfer efficiency between surfaces of sheets and surrounding airflow. The temperature on the sheets was chosen to observe the effects of different sheets material, various heat power and airflow velocity. During the experiment a thermal input below the sheets and airflow velocity through the tunnel have been changed. The thermal field distribution on the metal sheet is different than in case of composite sheet. For the composite material the thermal field distribution was more homogeneous. This article describe briefly also methods of obtaining real composite geometry based on scanned data and their reconstruction for using in some future numerical models.

  17. The construction of ventilation turrets in Atta vollenweideri leaf-cutting ants: Carbon dioxide levels in the nest tunnels, but not airflow or air humidity, influence turret structure.

    Directory of Open Access Journals (Sweden)

    Florian Halboth

    Full Text Available Nest ventilation in the leaf-cutting ant Atta vollenweideri is driven via a wind-induced mechanism. On their nests, workers construct small turrets that are expected to facilitate nest ventilation. We hypothesized that the construction and structural features of the turrets would depend on the colony's current demands for ventilation and thus might be influenced by the prevailing environmental conditions inside the nest. Therefore, we tested whether climate-related parameters, namely airflow, air humidity and CO2 levels in the outflowing nest air influenced turret construction in Atta vollenweideri. In the laboratory, we simulated a semi-natural nest arrangement with fungus chambers, a central ventilation tunnel providing outflow of air and an aboveground building arena for turret construction. In independent series, different climatic conditions inside the ventilation tunnel were experimentally generated, and after 24 hours, several features of the built turret were quantified, i.e., mass, height, number and surface area (aperture of turret openings. Turret mass and height were similar in all experiments even when no airflow was provided in the ventilation tunnel. However, elevated CO2 levels led to the construction of a turret with several minor openings and a larger total aperture. This effect was statistically significant at higher CO2 levels of 5% and 10% but not at 1% CO2. The construction of a turret with several minor openings did not depend on the strong differences in CO2 levels between the outflowing and the outside air, since workers also built permeated turrets even when the CO2 levels inside and outside were both similarly high. We propose that the construction of turrets with several openings and larger opening surface area might facilitate the removal of CO2 from the underground nest structure and could therefore be involved in the control of nest climate in leaf-cutting ants.

  18. High-Rate Disinfection Techniques for Combined Sewer Overflow (Proceedings Paper)

    Science.gov (United States)

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH ), a...

  19. Physical nature of strain rate sensitivity of metals and alloys at high strain rates

    Science.gov (United States)

    Borodin, E. N.; Gruzdkov, A. A.; Mayer, A. E.; Selyutina, N. S.

    2018-04-01

    The role of instabilities of plastic flow at plastic deformation of various materials is one of the important cross-disciplinary problems which is equally important in physics, mechanics and material science. The strain rate sensitivities under slow and high strain rate conditions of loading have different physical nature. In the case of low strain rate, the sensitivity arising from the inertness of the defect structures evolution can be expressed by a single parameter characterizing the plasticity mechanism. In our approach, this is the value of the characteristic relaxation time. In the dynamic case, there are additional effects of “high-speed sensitivity” associated with the micro-localization of the plastic flow near the stress concentrators. In the frames of mechanical description, this requires to introduce additional strain rate sensitivity parameters, which is realized in numerous modifications of Johnson–Cook and Zerilli–Armstrong models. The consideration of both these factors is fundamental for an adequate description of the problems of dynamic deformation of highly inhomogeneous metallic materials such as steels and alloys. The measurement of the dispersion of particle velocities on the free surface of a shock-loaded material can be regarded as an experimental expression of the effect of micro-localization. This is also confirmed by our results of numerical simulation of the propagation of shock waves in a two-dimensional formulation and analytical estimations.

  20. Investigation of the drying airflow at a newly developed dryer geometry for mixed flow grain dryers

    Directory of Open Access Journals (Sweden)

    Holger Scaar

    2016-06-01

    Full Text Available The mixed-flow dryer has been a matter of investigation many times regarding drying efficiency, dryer control, and performance enhancement over the past years. However, there is still considerable demand for optimization in terms of energy efficiency and homogeneity of drying. In order to analyze the specific energy consumption and the homogeneity of the drying process, different thermodynamic process conditions have been investigated for the conventional MFD design using numerical and experimental methods. Based on the results obtained, a novel dryer design has been developed. With this, a considerable increase of efficiency is expected. As the fluid dynamic analysis of the first design draft revealed, further development is required until scaling-up and transfer into practice will be possible. While homogeneous airflow conditions could be demonstrated in the core flow region in the center of the dryer, the configuration must be optimized in the near wall regions.

  1. Radiobiological aspects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation

    International Nuclear Information System (INIS)

    Turesson, I.

    1990-01-01

    The biological effects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation in interstitial and intracavitary radiotherapy and total body irradiation are discussed in terms of dose-rate fractionation sensitivity for various tissues. A scaling between dose-rate and fraction size was established for acute and late normal-tissue effects which can serve as a guideline for local treatment in the range of dose rates between 0.02 and 0.005 Gy/min and fraction sizes between 8.5 and 2.5 Gy. This is valid provided cell-cycle progression and proliferation can be ignored. Assuming that the acute and late tissue responses are characterized by α/β values of about 10 and 3 Gy and a mono-exponential repair half-time of about 3 h, the same total doses given with either of the two methods are approximately equivalent. The equivalence for acute and late non-hemopoietic normal tissue damage is 0.02 Gy/min and 8.5 Gy per fraction; 0.01 Gy/min and 5.5 Gy per fraction; and 0.005 Gy/min and 2.5Gy per fraction. A very low dose rate, below 0.005 Gy/min, is thus necessary to simulate high dose-rate radiotherapy with fraction sizes of about 2Gy. The scaling factor is, however, dependent on the repair half-time of the tissue. A review of published data on dose-rate effects for normal tissue response showed a significantly stronger dose-rate dependence for late than for acute effects below 0.02 Gy/min. There was no significant difference in dose-rate dependence between various acute non-hemopoietic effects or between various late effects. The consistent dose-rate dependence, which justifies the use of a general scaling factor between fraction size and dose rate, contrasts with the wide range of values for repair half-time calculated for various normal-tissue effects. This indicates that the model currently used for repair kinetics is not satisfactory. There are also few experimental data in the clinical dose-rate range, below 0.02 Gy/min. It is therefore

  2. Investigation of high-rate lithium-thionyl chloride cells

    Science.gov (United States)

    Hayes, Catherine A.; Gust, Steven; Farrington, Michael D.; Lockwood, Judith A.; Donaldson, George J.

    Chemical analysis of a commercially produced high-rate D-size lithium-thionyl cell was carried out, as a function of rate of discharge (1 ohm and 5 ohms), depth of discharge, and temperature (25 C and -40 C), using specially developed methods for identifying suspected minor cell products or impurities which may effect cell performance. These methods include a product-retrieval system which involves solvent extraction to enhance the recovery of suspected semivolatile minor chemicals, and methods of quantitative GC analysis of volatile and semivolatile products. The nonvolatile products were analyzed by wet chemical methods. The results of the analyses indicate that the predominant discharge reaction in this cell is 4Li + 2SOCl2 going to 4LiCl + S + SO2, with SO2 formation decreasing towards the end of cell life (7 to 12 Ah). The rate of discharge had no effect on the product distribution. Upon discharge of the high-rate cell at -40 C, one cell exploded, and all others exhibited overheating and rapid internal pressure rise when allowed to warm up to room temperature.

  3. High throughput route selection in multi-rate wireless mesh networks

    Institute of Scientific and Technical Information of China (English)

    WEI Yi-fei; GUO Xiang-li; SONG Mei; SONG Jun-de

    2008-01-01

    Most existing Ad-hoc routing protocols use the shortest path algorithm with a hop count metric to select paths. It is appropriate in single-rate wireless networks, but has a tendency to select paths containing long-distance links that have low data rates and reduced reliability in multi-rate networks. This article introduces a high throughput routing algorithm utilizing the multi-rate capability and some mesh characteristics in wireless fidelity (WiFi) mesh networks. It uses the medium access control (MAC) transmission time as the routing metric, which is estimated by the information passed up from the physical layer. When the proposed algorithm is adopted, the Ad-hoc on-demand distance vector (AODV) routing can be improved as high throughput AODV (HT-AODV). Simulation results show that HT-AODV is capable of establishing a route that has high data-rate, short end-to-end delay and great network throughput.

  4. Quantum Communication with a High-Rate Entangled Photon Source

    Science.gov (United States)

    Wilson, Nathaniel C.; Chaffee, Dalton W.; Lekki, John D.; Wilson, Jeffrey D.

    2016-01-01

    A high generation rate photon-pair source using a dual element periodically-poled potassium titanyl phosphate (PP KTP) waveguide is described. The photon-pair source features a high pair generation rate, a compact power-efficient package, and continuous wave (CW) or pulsed operation. Characterization and test results are presented. Details and preliminary results of a laboratory free-space QKD experiment with the B92 protocol are also presented.

  5. Assessment of ventilation efficiency for the study of indoor air quality; Appreciation de l'efficacite de la ventilation pour l'etude de la qualite de l'air interieur

    Energy Technology Data Exchange (ETDEWEB)

    Akoua, A.A.

    2004-10-15

    An efficient ventilation system provides a good indoor air quality by eliminating air pollutants and ensuring a satisfactory air renewal. Unlike most research works that deal with test cells with controlled boundary conditions, our study focuses on ventilation efficiency in a real environment. In situ experiments are performed and provide the boundary conditions necessary for CFD (Computational Fluid Dynamics) computations. Using CFD for predicting indoor air quality in a real environment is thus analyzed. The influence of permeability on numerical predictions quality is shown. Unfortunately, it is difficult to quantify accurately the air leakages and their airflow rates. Our study proposes a simplified model that includes air infiltration rates in the CFD computations, and that yields satisfactory results. A critical analysis of ventilation efficiency indices is then performed. It is shown that it is currently impossible to evaluate the air change efficiency ( a e ) in an occupied zone. Concerning the air pollutants removal effectiveness, it is shown that the usual index C e is not suited to ventilation systems with variable airflow rates. For such cases, a new formulation of this index is given. The ratio between the airflow rate and the nominal airflow rate of the ventilation system is also taken into consideration. A coupled analysis of this new index and of this airflow rate ratio enables us to assess the air pollutants removal effectiveness while considering the energetic cost of ventilation. We finally show that there is no universal index. The choice of the index depends on the pollutant, on the pollutant concentration, and on the airflow rate. A tool of decision-making aid is thus proposed in order to evaluate the air pollutants removal effectiveness for various ventilation systems. This tool is flexible and rather simple to use. (author)

  6. High-Rate Data-Capture for an Airborne Lidar System

    Science.gov (United States)

    Valett, Susan; Hicks, Edward; Dabney, Philip; Harding, David

    2012-01-01

    A high-rate data system was required to capture the data for an airborne lidar system. A data system was developed that achieved up to 22 million (64-bit) events per second sustained data rate (1408 million bits per second), as well as short bursts (less than 4 s) at higher rates. All hardware used for the system was off the shelf, but carefully selected to achieve these rates. The system was used to capture laser fire, single-photon detection, and GPS data for the Slope Imaging Multi-polarization Photo-counting Lidar (SIMPL). However, the system has applications for other laser altimeter systems (waveform-recording), mass spectroscopy, xray radiometry imaging, high-background- rate ranging lidar, and other similar areas where very high-speed data capture is needed. The data capture software was used for the SIMPL instrument that employs a micropulse, single-photon ranging measurement approach and has 16 data channels. The detected single photons are from two sources those reflected from the target and solar background photons. The instrument is non-gated, so background photons are acquired for a range window of 13 km and can comprise many times the number of target photons. The highest background rate occurs when the atmosphere is clear, the Sun is high, and the target is a highly reflective surface such as snow. Under these conditions, the total data rate for the 16 channels combined is expected to be approximately 22 million events per second. For each photon detection event, the data capture software reads the relative time of receipt, with respect to a one-per-second absolute time pulse from a GPS receiver, from an event timer card with 0.1-ns precision, and records that information to a RAID (Redundant Array of Independent Disks) storage device. The relative time of laser pulse firings must also be read and recorded with the same precision. Each of the four event timer cards handles the throughput from four of the channels. For each detection event, a flag is

  7. Yield strength of molybdenum, tantalum and tungsten at high strain rates and very high temperatures

    International Nuclear Information System (INIS)

    Škoro, G.P.; Bennett, J.R.J.; Edgecock, T.R.; Booth, C.N.

    2012-01-01

    Highlights: ► New experimental data on the yield strength of molybdenum, tantalum and tungsten. ► High strain rate effects at record high temperatures (up to 2700 K). ► Test of the consistency of the Zerilli–Armstrong model at very high temperatures. - Abstract: Recently reported results of the high strain rate, high temperature measurements of the yield strength of tantalum and tungsten have been analyzed along with new experimental results on the yield strength of molybdenum. Thin wires are subjected to high stress by passing a short, fast, high current pulse through a thin wire; the amplitude of the current governs the stress and the repetition rate of the pulses determines the temperature of the wire. The highest temperatures reached in the experiments were 2100 °C (for molybdenum), 2250 °C (for tantalum) and 2450 °C (for tungsten). The strain-rates in the tests were in the range from 500 to 1500 s −1 . The parameters for the constitutive equation developed by Zerilli and Armstrong have been determined from the experimental data and the results have been compared with the data obtained at lower temperatures. An exceptionally good fit is obtained for the deformation of tungsten.

  8. Wind observations above an urban river using a new lidar technique, scintillometry and anemometry

    Energy Technology Data Exchange (ETDEWEB)

    Wood, C.R. [Department of Meteorology, University of Reading, Reading, RG6 6BB (United Kingdom); Finnish Meteorological Institute, Erik Palmenin aukio 1, Helsinki, 00101 (Finland); Pauscher, L. [King' s College London, Department of Geography, London, WC2R 2LS (United Kingdom); Ward, H.C. [King' s College London, Department of Geography, London, WC2R 2LS (United Kingdom); Centre for Ecology and Hydrology, Wallingford, Oxfordshire, OX10 8BB (United Kingdom); Kotthaus, S. [King' s College London, Department of Geography, London, WC2R 2LS (United Kingdom); Barlow, J.F., E-mail: j.f.barlow@reading.ac.uk [Department of Meteorology, University of Reading, Reading, RG6 6BB (United Kingdom); Gouvea, M. [King' s College London, Department of Geography, London, WC2R 2LS (United Kingdom); Lane, S.E. [Department of Meteorology, University of Reading, Reading, RG6 6BB (United Kingdom); Grimmond, C.S.B. [King' s College London, Department of Geography, London, WC2R 2LS (United Kingdom)

    2013-01-01

    Airflow along rivers might provide a key mechanism for ventilation in cities: important for air quality and thermal comfort. Airflow varies in space and time in the vicinity of rivers. Consequently, there is limited utility in point measurements. Ground-based remote sensing offers the opportunity to study 3D airflow in locations which are difficult to observe with conventional approaches. For three months in the winter and spring of 2011, the airflow above the River Thames in central London was observed using a scanning Doppler lidar, a scintillometer and sonic anemometers. First, an inter-comparison showed that lidar-derived mean wind-speed estimates compare almost as well to sonic anemometers (root-mean-square error (rmse) 0.65-0.68 m s{sup -1}) as comparisons between sonic anemometers (0.35-0.73 m s{sup -1}). Second, the lidar duo-beam operating strategy provided horizontal transects of wind vectors (comparison with scintillometer rmse 1.12-1.63 m s{sup -1}) which revealed mean and turbulent airflow across the river and surrounds; in particular, channelled airflow along the river and changes in turbulence quantities consistent with the roughness changes between built and river environments. The results have important consequences for air quality and dispersion around urban rivers, especially given that many cities have high traffic rates on roads located on riverbanks. -- Highlights: Black-Right-Pointing-Pointer An inter-comparison was made between lidar-derived winds and regular anemometry. Black-Right-Pointing-Pointer A new lidar operating technique was developed. Black-Right-Pointing-Pointer Airflow features above an urban river included channelling of wind.

  9. Wind observations above an urban river using a new lidar technique, scintillometry and anemometry

    International Nuclear Information System (INIS)

    Wood, C.R.; Pauscher, L.; Ward, H.C.; Kotthaus, S.; Barlow, J.F.; Gouvea, M.; Lane, S.E.; Grimmond, C.S.B.

    2013-01-01

    Airflow along rivers might provide a key mechanism for ventilation in cities: important for air quality and thermal comfort. Airflow varies in space and time in the vicinity of rivers. Consequently, there is limited utility in point measurements. Ground-based remote sensing offers the opportunity to study 3D airflow in locations which are difficult to observe with conventional approaches. For three months in the winter and spring of 2011, the airflow above the River Thames in central London was observed using a scanning Doppler lidar, a scintillometer and sonic anemometers. First, an inter-comparison showed that lidar-derived mean wind-speed estimates compare almost as well to sonic anemometers (root-mean-square error (rmse) 0.65–0.68 m s −1 ) as comparisons between sonic anemometers (0.35–0.73 m s −1 ). Second, the lidar duo-beam operating strategy provided horizontal transects of wind vectors (comparison with scintillometer rmse 1.12–1.63 m s −1 ) which revealed mean and turbulent airflow across the river and surrounds; in particular, channelled airflow along the river and changes in turbulence quantities consistent with the roughness changes between built and river environments. The results have important consequences for air quality and dispersion around urban rivers, especially given that many cities have high traffic rates on roads located on riverbanks. -- Highlights: ► An inter-comparison was made between lidar-derived winds and regular anemometry. ► A new lidar operating technique was developed. ► Airflow features above an urban river included channelling of wind.

  10. High production rate of IBAD-MgO buffered substrate

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, M., E-mail: myoshizumi@istec.or.j [Superconductivity Research Laboratory, ISTEC, Shinonome 1-10-13, Koto-ku, Tokyo 135-0062 (Japan); Miyata, S.; Ibi, A.; Fukushima, H.; Yamada, Y.; Izumi, T.; Shiohara, Y. [Superconductivity Research Laboratory, ISTEC, Shinonome 1-10-13, Koto-ku, Tokyo 135-0062 (Japan)

    2009-10-15

    The conventional IBAD (Ion Beam Assisted Deposition) process using fluorite materials yields low production rates, resulting in high production cost, which reduces the motivation for practical application in spite of its high quality. The IBAD process using rock salt materials, e.g. MgO, is well known as a strong candidate of practical application due to its potential of high production rate and high in-plane grain alignment. In this work, the IBAD-MgO process was investigated for a newly developed architecture of PLD (Pulsed Laser Deposition)-CeO{sub 2}/sputter-LMO (LaMnO{sub 3})/IBAD-MgO/sputter-GZO (Gd{sub 2}Zr{sub 2}O{sub 7})/Hastelloy{sup TM} to make long buffered metal tapes with high properties and a high production rate. The 50 m-long IBAD-MgO substrates with about 4 deg. of DELTAphiCeO{sub 2} in an XRD phi scan could be fabricated repeatedly. A GdBCO (GdBa{sub 2}Cu{sub 3}O{sub x}) layer deposited on the buffered substrate showed the minimum I{sub c} value of 325 A/cm-w in a 41 m-long tape. Almost of the tape showed 500-600 A/cm-w of I{sub c} value. The deposition time for the IBAD-MgO layer was 60 s which was about 2 orders of magnitude shorter than the conventional IBAD process. The production rate of 24 m/h was realized at the IBAD-MgO process to fabricate the GdBCO coated conductor with high J{sub c} and I{sub c} properties.

  11. High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ghadjar, Pirus, E-mail: pirus.ghadjar@insel.ch [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Bojaxhiu, Beat [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Simcock, Mathew [Swiss Group for Clinical Cancer Research Coordinating Center, Bern (Switzerland); Terribilini, Dario; Isaak, Bernhard [Division of Medical Radiation Physics, Inselspital, Bern University Hospital, and University of Bern, Bern (Switzerland); Gut, Philipp; Wolfensberger, Patrick; Broemme, Jens O.; Geretschlaeger, Andreas; Behrensmeier, Frank; Pica, Alessia; Aebersold, Daniel M. [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland)

    2012-07-15

    Purpose: To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer. Methods and Materials: One hundred and three patients with newly diagnosed squamous cell carcinoma of the lip were treated between March 1985 and June 2009 either by HDR (n = 33) or LDR brachytherapy (n = 70). Sixty-eight patients received brachytherapy alone, and 35 received tumor excision followed by brachytherapy because of positive resection margins. Acute and late toxicity was assessed according to the Common Terminology Criteria for Adverse Events 3.0. Results: Median follow-up was 3.1 years (range, 0.3-23 years). Clinical and pathological variables did not differ significantly between groups. At 5 years, local recurrence-free survival, regional recurrence-free survival, and overall survival rates were 93%, 90%, and 77%. There was no significant difference for these endpoints when HDR was compared with LDR brachytherapy. Forty-two of 103 patients (41%) experienced acute Grade 2 and 57 of 103 patients (55%) experienced acute Grade 3 toxicity. Late Grade 1 toxicity was experienced by 34 of 103 patients (33%), and 5 of 103 patients (5%) experienced late Grade 2 toxicity; no Grade 3 late toxicity was observed. Acute and late toxicity rates were not significantly different between HDR and LDR brachytherapy. Conclusions: As treatment for lip cancer, HDR and LDR brachytherapy have comparable locoregional control and acute and late toxicity rates. HDR brachytherapy for lip cancer seems to be an effective treatment with acceptable toxicity.

  12. Improved Cathode Structure for a Direct Methanol Fuel Cell

    Science.gov (United States)

    Valdez, Thomas; Narayanan, Sekharipuram

    2005-01-01

    An improved cathode structure on a membrane/electrode assembly has been developed for a direct methanol fuel cell, in a continuing effort to realize practical power systems containing such fuel cells. This cathode structure is intended particularly to afford better cell performance at a low airflow rate. A membrane/electrode assembly of the type for which the improved cathode structure was developed (see Figure 1) is fabricated in a process that includes brush painting and spray coating of catalyst layers onto a polymer-electrolyte membrane and onto gas-diffusion backings that also act as current collectors. The aforementioned layers are then dried and hot-pressed together. When completed, the membrane/electrode assembly contains (1) an anode containing a fine metal black of Pt/Ru alloy, (2) a membrane made of Nafion 117 or equivalent (a perfluorosulfonic acid-based hydrophilic, proton-conducting ion-exchange polymer), (3) a cathode structure (in the present case, the improved cathode structure described below), and (4) the electrically conductive gas-diffusion backing layers, which are made of Toray 060(TradeMark)(or equivalent) carbon paper containing between 5 and 6 weight percent of poly(tetrafluoroethylene). The need for an improved cathode structure arises for the following reasons: In the design and operation of a fuel-cell power system, the airflow rate is a critical parameter that determines the overall efficiency, cell voltage, and power density. It is desirable to operate at a low airflow rate in order to obtain thermal and water balance and to minimize the size and mass of the system. The performances of membrane/electrode assemblies of prior design are limited at low airflow rates. Methanol crossover increases the required airflow rate. Hence, one way to reduce the required airflow rate is to reduce the effect of methanol crossover. Improvement of the cathode structure - in particular, addition of hydrophobic particles to the cathode - has been

  13. Mechanical characterization of alloys in extreme conditions of high strain rates and high temperature

    Science.gov (United States)

    Cadoni, Ezio

    2018-03-01

    The aim of this paper is the description of the mechanical characterization of alloys under extreme conditions of temperature and loading. In fact, in the frame of the Cost Action CA15102 “Solutions for Critical Raw Materials Under Extreme Conditions (CRM-EXTREME)” this aspect is crucial and many industrial applications have to consider the dynamic response of materials. Indeed, for a reduction and substitution of CRMs in alloys is necessary to design the materials and understand if the new materials behave better or if the substitution or reduction badly affect their performance. For this reason, a deep knowledge of the mechanical behaviour at high strain-rates of considered materials is required. In general, machinery manufacturing industry or transport industry as well as energy industry have important dynamic phenomena that are simultaneously affected by extended strain, high strain-rate, damage and pressure, as well as conspicuous temperature gradients. The experimental results in extreme conditions of high strain rate and high temperature of an austenitic stainless steel as well as a high-chromium tempered martensitic reduced activation steel Eurofer97 are presented.

  14. Electrophoretic Deposition of Gallium with High Deposition Rate

    Directory of Open Access Journals (Sweden)

    Hanfei Zhang

    2014-12-01

    Full Text Available In this work, electrophoretic deposition (EPD is reported to form gallium thin film with high deposition rate and low cost while avoiding the highly toxic chemicals typically used in electroplating. A maximum deposition rate of ~0.6 μm/min, almost one order of magnitude higher than the typical value reported for electroplating, is obtained when employing a set of proper deposition parameters. The thickness of the film is shown to increase with deposition time when sequential deposition is employed. The concentration of Mg(NO32, the charging salt, is also found to be a critical factor to control the deposition rate. Various gallium micropatterns are obtained by masking the substrate during the process, demonstrating process compatibility with microfabrication. The reported novel approach can potentially be employed in a broad range of applications with Ga as a raw material, including microelectronics, photovoltaic cells, and flexible liquid metal microelectrodes.

  15. High strain-rate soft material characterization via inertial cavitation

    Science.gov (United States)

    Estrada, Jonathan B.; Barajas, Carlos; Henann, David L.; Johnsen, Eric; Franck, Christian

    2018-03-01

    Mechanical characterization of soft materials at high strain-rates is challenging due to their high compliance, slow wave speeds, and non-linear viscoelasticity. Yet, knowledge of their material behavior is paramount across a spectrum of biological and engineering applications from minimizing tissue damage in ultrasound and laser surgeries to diagnosing and mitigating impact injuries. To address this significant experimental hurdle and the need to accurately measure the viscoelastic properties of soft materials at high strain-rates (103-108 s-1), we present a minimally invasive, local 3D microrheology technique based on inertial microcavitation. By combining high-speed time-lapse imaging with an appropriate theoretical cavitation framework, we demonstrate that this technique has the capability to accurately determine the general viscoelastic material properties of soft matter as compliant as a few kilopascals. Similar to commercial characterization algorithms, we provide the user with significant flexibility in evaluating several constitutive laws to determine the most appropriate physical model for the material under investigation. Given its straightforward implementation into most current microscopy setups, we anticipate that this technique can be easily adopted by anyone interested in characterizing soft material properties at high loading rates including hydrogels, tissues and various polymeric specimens.

  16. Electronics for very high rate tracking detectors

    International Nuclear Information System (INIS)

    Williams, H.H.; Dressnandt, N.; Ekenberg, T.; Gerds, E.J.; Newcomer, F.M.; Tedja, S.; Van Berg, R.; Van der Speigel, J.

    1995-01-01

    Results are presented on a system of electronics designed for very high rate tracking detectors at the SSC and LHC. The primary goal was a system for signal detection, time measurement, and readout for the straw tracker for SDC. An integrated circuit incorporating eight channels of amplifier-shaper-discriminator (including detector tail cancellation), and two different integrated circuits for time measurement are described. The performance of tracking measurements up to counting rates of 8 MHz per wire is reported, as well as preliminary results from a baseline restoration circuit. (orig.)

  17. High rate spectroscopy for on-line nuclear coal analyzer (Nucoalyzer)

    International Nuclear Information System (INIS)

    McQuaid, J.H.; Brown, D.R.; Gozani, T.; Bozorgmanesh, H.

    1980-01-01

    A high count rate, time-variant Ge(Li) spectrometer has been developed for on-line coal analysis. The analyzer is being fabricated for use in a power generating station. Prompt neutron activation of coal samples is the basis of analysis, with 252 Cf as the source for irradiation. The spectroscopy system allows counting rates up to 150 k counts per second without significant loss in energy resolution or peak shape. The high data throughput allows the coal analyzer to be used for on-line process control. The coal analyzer will be discussed, with emphasis on the high-rate signal processing system. Results of analysis of coal samples will be presented

  18. High counting rate resistive-plate chamber

    International Nuclear Information System (INIS)

    Peskov, V.; Anderson, D.F.; Kwan, S.

    1993-05-01

    Parallel-plate avalanche chambers (PPAC) are widely used in physics experiments because they are fast ( 5 counts/mm 2 . A resistive-plate chamber (RPC) is similar to the PPAC in construction except that one or both of the electrodes are made from high resistivity (≥10 10 Ω·cm) materials. In practice RPCs are usually used in the spark mode. Resistive electrodes are charged by sparks, locally reducing the actual electric field in the gap. The size of the charged surface is about 10 mm 2 , leaving the rest of the detector unaffected. Therefore, the rate capability of such detectors in the spark mode is considerably higher than conventional spark counters. Among the different glasses tested the best results were obtained with electron type conductive glasses, which obey Ohm's law. Most of the work with such glasses was done with high pressure parallel-plate chambers (10 atm) for time-of-flight measurements. Resistive glasses have been expensive and produced only in small quantities. Now resistive glasses are commercially available, although they are still expensive in small scale production. From the positive experience of different groups working with the resistive glasses, it was decided to review the old idea to use this glass for the RPC. This work has investigated the possibility of using the RPC at 1 atm and in the avalanche mode. This has several advantages: simplicity of construction, high rate capability, low voltage operation, and the ability to work with non-flammable gases

  19. Autonomous Sensors Powered by Energy Harvesting from von Karman Vortices in Airflow.

    Science.gov (United States)

    Demori, Marco; Ferrari, Marco; Bonzanini, Arianna; Poesio, Pietro; Ferrari, Vittorio

    2017-09-13

    In this paper an energy harvesting system based on a piezoelectric converter to extract energy from airflow and use it to power battery-less sensors is presented. The converter is embedded as a part of a flexure beam that is put into vibrations by von Karman vortices detached from a bluff body placed upstream. The vortex street has been investigated by Computational Fluid Dynamics (CFD) simulations, aiming at assessing the vortex shedding frequency as a function of the flow velocity. From the simulation results the preferred positioning of the beam behind the bluff body has been derived. In the experimental characterization the electrical output from the converter has been measured for different flow velocities and beam orientations. Highest conversion effectiveness is obtained by an optimal orientation of the beam, to exploit the maximum forcing, and for flow velocities where the repetition frequency of the vortices allows to excite the beam resonant frequency at its first flexural mode. The possibility to power battery-less sensors and make them autonomous has been shown by developing an energy management and signal conditioning electronic circuit plus two sensors for measuring temperature and flow velocity and transmitting their values over a RF signal. A harvested power of about 650 μW with retransmission intervals below 2 min have been obtained for the optimal flow velocity of 4 m/s.

  20. Autonomous Sensors Powered by Energy Harvesting from von Karman Vortices in Airflow

    Directory of Open Access Journals (Sweden)

    Marco Demori

    2017-09-01

    Full Text Available In this paper an energy harvesting system based on a piezoelectric converter to extract energy from airflow and use it to power battery-less sensors is presented. The converter is embedded as a part of a flexure beam that is put into vibrations by von Karman vortices detached from a bluff body placed upstream. The vortex street has been investigated by Computational Fluid Dynamics (CFD simulations, aiming at assessing the vortex shedding frequency as a function of the flow velocity. From the simulation results the preferred positioning of the beam behind the bluff body has been derived. In the experimental characterization the electrical output from the converter has been measured for different flow velocities and beam orientations. Highest conversion effectiveness is obtained by an optimal orientation of the beam, to exploit the maximum forcing, and for flow velocities where the repetition frequency of the vortices allows to excite the beam resonant frequency at its first flexural mode. The possibility to power battery-less sensors and make them autonomous has been shown by developing an energy management and signal conditioning electronic circuit plus two sensors for measuring temperature and flow velocity and transmitting their values over a RF signal. A harvested power of about 650 μW with retransmission intervals below 2 min have been obtained for the optimal flow velocity of 4 m/s.

  1. Microstructural evolution at high strain rates in solution-hardened interstitial free steels

    International Nuclear Information System (INIS)

    Uenishi, A.; Teodosiu, C.; Nesterova, E.V.

    2005-01-01

    Comprehensive transmission electron microscopical studies have been conducted for solution-hardened steels deformed at high (1000 s -1 ) and low (0.001 s -1 ) strain rates, in order to clarify the effects of strain rate and a jump in strain rate on the evolution of the microstructure and its connection with the mechanical response. It was revealed that the various types of microstructure, observed even within the same specimen, depend on the corresponding grain orientations and their evolution with progressive deformation depends on these microstructure types. At high strain rates, the dislocation density increases especially at low strains and the onset of dislocation organization is delayed. A jump in strain rate causes an increase of the dislocation density inside an organized structure. These results corroborated the mechanical behaviour at high strain rates after compensation for the cross-sectional reduction and temperature increase. The higher work-hardening rate at high strain rates could be connected to a delay in the dislocation organization. The high work-hardening rate just after a jump could be due to an increase of the density of dislocations distributed uniformly inside an organized structure

  2. Delayed high school start times later than 8:30am and impact on graduation rates and attendance rates.

    Science.gov (United States)

    McKeever, Pamela Malaspina; Clark, Linda

    2017-04-01

    The first purpose of this study was to investigate changes in high school graduation rates with a delayed school start time of later than 8:30am. The second aim of the study was to analyze the association between a delayed high school start time later than 8:30am and attendance rates. In the current study, a pre-post design using a repeated-measures analysis of variance was used to examine changes in attendance and graduation rates 2 years after a delayed start was implemented. Public high schools from 8 school districts (n=29 high schools) located throughout 7 different states. Schools were identified using previous research from the Children's National Medical Center's Division of Sleep Medicine Research Team. A total membership of more than 30,000 high school students enrolled in the 29 schools identified by the Children's National Medical Center's Research Team. A pre-post design was used for a within-subject design, controlling for any school-to-school difference in the calculation of the response variable. This is the recommended technique for a study that may include data with potential measurement error. Findings from this study linked a start time of later than 8:30am to improved attendance rates and graduation rates. Attendance rates and graduation rates significantly improved in schools with delayed start times of 8:30am or later. School officials need to take special notice that this investigation also raises questions about whether later start times are a mechanism for closing the achievement gap due to improved graduation rates. Copyright © 2017 National Sleep Foundation. Published by Elsevier Inc. All rights reserved.

  3. High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer

    International Nuclear Information System (INIS)

    Ghadjar, Pirus; Bojaxhiu, Beat; Simcock, Mathew; Terribilini, Dario; Isaak, Bernhard; Gut, Philipp; Wolfensberger, Patrick; Brömme, Jens O.; Geretschläger, Andreas; Behrensmeier, Frank; Pica, Alessia; Aebersold, Daniel M.

    2012-01-01

    Purpose: To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer. Methods and Materials: One hundred and three patients with newly diagnosed squamous cell carcinoma of the lip were treated between March 1985 and June 2009 either by HDR (n = 33) or LDR brachytherapy (n = 70). Sixty-eight patients received brachytherapy alone, and 35 received tumor excision followed by brachytherapy because of positive resection margins. Acute and late toxicity was assessed according to the Common Terminology Criteria for Adverse Events 3.0. Results: Median follow-up was 3.1 years (range, 0.3–23 years). Clinical and pathological variables did not differ significantly between groups. At 5 years, local recurrence-free survival, regional recurrence-free survival, and overall survival rates were 93%, 90%, and 77%. There was no significant difference for these endpoints when HDR was compared with LDR brachytherapy. Forty-two of 103 patients (41%) experienced acute Grade 2 and 57 of 103 patients (55%) experienced acute Grade 3 toxicity. Late Grade 1 toxicity was experienced by 34 of 103 patients (33%), and 5 of 103 patients (5%) experienced late Grade 2 toxicity; no Grade 3 late toxicity was observed. Acute and late toxicity rates were not significantly different between HDR and LDR brachytherapy. Conclusions: As treatment for lip cancer, HDR and LDR brachytherapy have comparable locoregional control and acute and late toxicity rates. HDR brachytherapy for lip cancer seems to be an effective treatment with acceptable toxicity.

  4. Preparation of Ultra-fine Calcium Carbonate by a Solvent-free ...

    African Journals Online (AJOL)

    The treatment of calcium chloride with sodium carbonate under solvent-free conditions with a supersonic airflow and at a low heating temperature leads to the synthesis of ultra-fine calcium carbonate. The reaction not only involves mild conditions, a simple operation, and high yields but also gives a high conversion rate.

  5. Increased strength of concrete subject to high loading rates

    International Nuclear Information System (INIS)

    Curbach, M.

    1987-01-01

    Within the scope of this work various problems are discussed which occur in connection with concrete under high tensile loading rates (e.g. when a plane crashes on a nuclear power plant very high loads occur which act only for a very short time). Particularly the causes for the already frequently noticed increases in strength with increasing loading rates are investigated and also the question whether this increased strength can be taken into account when dimensioning a construction. (MM) [de

  6. Authoritative School Climate and High School Dropout Rates

    Science.gov (United States)

    Jia, Yuane; Konold, Timothy R.; Cornell, Dewey

    2016-01-01

    This study tested the association between school-wide measures of an authoritative school climate and high school dropout rates in a statewide sample of 315 high schools. Regression models at the school level of analysis used teacher and student measures of disciplinary structure, student support, and academic expectations to predict overall high…

  7. Consistent high clinical pregnancy rates and low ovarian hyperstimulation syndrome rates in high-risk patients after GnRH agonist triggering and modified luteal support

    DEFF Research Database (Denmark)

    Iliodromiti, Stamatina; Blockeel, Christophe; Tremellen, Kelton P

    2013-01-01

    Are clinical pregnancy rates satisfactory and the incidence of OHSS low after GnRH agonist trigger and modified intensive luteal support in patients with a high risk of ovarian hyperstimulation syndrome (OHSS)?......Are clinical pregnancy rates satisfactory and the incidence of OHSS low after GnRH agonist trigger and modified intensive luteal support in patients with a high risk of ovarian hyperstimulation syndrome (OHSS)?...

  8. Video-rate or high-precision: a flexible range imaging camera

    Science.gov (United States)

    Dorrington, Adrian A.; Cree, Michael J.; Carnegie, Dale A.; Payne, Andrew D.; Conroy, Richard M.; Godbaz, John P.; Jongenelen, Adrian P. P.

    2008-02-01

    A range imaging camera produces an output similar to a digital photograph, but every pixel in the image contains distance information as well as intensity. This is useful for measuring the shape, size and location of objects in a scene, hence is well suited to certain machine vision applications. Previously we demonstrated a heterodyne range imaging system operating in a relatively high resolution (512-by-512) pixels and high precision (0.4 mm best case) configuration, but with a slow measurement rate (one every 10 s). Although this high precision range imaging is useful for some applications, the low acquisition speed is limiting in many situations. The system's frame rate and length of acquisition is fully configurable in software, which means the measurement rate can be increased by compromising precision and image resolution. In this paper we demonstrate the flexibility of our range imaging system by showing examples of high precision ranging at slow acquisition speeds and video-rate ranging with reduced ranging precision and image resolution. We also show that the heterodyne approach and the use of more than four samples per beat cycle provides better linearity than the traditional homodyne quadrature detection approach. Finally, we comment on practical issues of frame rate and beat signal frequency selection.

  9. Plasma-Assisted Chemistry in High-Speed Flow

    International Nuclear Information System (INIS)

    Leonov, Sergey B.; Yarantsev, Dmitry A.; Napartovich, Anatoly P.; Kochetov, Igor V.

    2007-01-01

    Fundamental problems related to the high-speed combustion are analyzed. The result of plasma-chemical modeling is presented as a motivation of experimental activity. Numerical simulations of the effect of uniform non-equilibrium discharge on the premixed hydrogen and ethylene-air mixture in supersonic flow demonstrate an advantage of such a technique over a heating. Experimental results on multi-electrode non-uniform discharge maintenance behind wallstep and in cavity of supersonic flow are presented. The model test on hydrogen and ethylene ignition is demonstrated at direct fuel injection to low-temperature high-speed airflow

  10. High-rate operant behavior in two mouse strains: a response-bout analysis.

    Science.gov (United States)

    Johnson, Joshua E; Pesek, Erin F; Newland, M Christopher

    2009-06-01

    Operant behavior sometimes occurs in bouts characterized by an initiation rate, within-bout response rate, and bout length. The generality of this structure was tested using high-rate nose-poking in mice. Reinforcement of short interresponse times produced high response rates while a random-interval schedule held reinforcement rates constant. BALB/c mice produced bouts that were more frequent, longer, and contained a higher within-bout rate of responding (nine nose-pokes/s) than did the C57BL/6 mice (five nose-pokes/s). Adding a running wheel decreased total nose-pokes and bout length, and increased bout-initiation rate. Free-feeding reduced nose-poking by decreasing bout-initiation rate. Photoperiod reversal decreased bout-initiation rate but not total nose-poke rate. Despite strain differences in bout structure, both strains responded similarly to the interventions. The three bout measures were correlated with overall rate but not with each other. Log-survival analyses provided independent descriptors of the structure of high-rate responding in these two strains.

  11. High-rate, High Temperature Acetotrophic Methanogenesis Governed by a Three Population Consortium in Anaerobic Bioreactors

    OpenAIRE

    Ho, Dang; Jensen, Paul; Gutierrez-Zamora, Maria-Luisa; Beckmann, Sabrina; Manefield, Mike; Batstone, Damien

    2016-01-01

    A combination of acetate oxidation and acetoclastic methanogenesis has been previously identified to enable high-rate methanogenesis at high temperatures (55 to 65°C), but this capability had not been linked to any key organisms. This study combined RNA-stable isotope probing on 13C-labelled acetate and 16S amplicon sequencing to identify the active micro-organisms involved in high-rate methanogenesis. Active biomass was harvested from three bench-scale thermophilic bioreactors treating waste...

  12. Relationship of airflow limitation severity with work productivity reduction and sick leave in a Japanese working population

    Directory of Open Access Journals (Sweden)

    Onoue A

    2016-03-01

    Full Text Available Ayumi Onoue,1 Hisamitsu Omori,1 Takahiko Katoh,2 Kenichi Kubota,3 Yoshio Nonami,3 Yasuhiro Ogata,3 Hiromasa Inoue4 1Department of Biomedical Laboratory Sciences, 2Department of Public Health, Faculty of Life Sciences, Kumamoto University, 3Japanese Red Cross Kumamoto Health Care Center, Kumamoto, 4Department of Pulmonary Medicine, Graduate School of Medical and Dental Sciences, Kagoshima University, Kagoshima, Japan Background: The aim of this study was to reveal the association between airflow limitation (AL severity and reduction with work productivity as well as use of sick leave among Japanese workers.Methods: This cross-sectional study included 1,378 workers who underwent a lung function test during a health checkup at the Japanese Red Cross Kumamoto Health Care Center. AL was defined as forced expiratory volume in 1 second/forced vital capacity of <0.7. Workers completed a questionnaire on productivity loss at work and sick leave. The quality and quantity of productivity loss at work were measured on a ten-point scale indicating how much work was actually performed on the previous workday. Participants were asked how many days in the past 12 months they were unable to work because of health problems. Logistic regression analysis was used to assess the associations between AL severity and the quality and quantity of productivity loss at work as well as use of sick leave.Results: Compared with workers without AL, workers with moderate-to-severe AL showed a significant productivity loss (quality: odds ratio [OR] =2.04, 95% confidence interval [CI]: 1.12–3.71, P=0.02 and quantity: OR =2.19, 95% CI: 1.20–4.00, P=0.011 and use of sick leave (OR =2.69, 95% CI: 1.33–5.44, P=0.006 after adjusting for sex, age, body mass index, smoking status, hypertension, hyperglycemia, dyslipidemia, sleep duration, work hours per day, and workplace smoking environment.Conclusion: AL severity was significantly associated with work productivity loss and use

  13. Flight Test Results from the Rake Airflow Gage Experiment on the F-15B Airplane

    Science.gov (United States)

    Frederick, Michael A.; Ratnayake, Nalin A.

    2011-01-01

    The Rake Airflow Gage Experiment involves a flow-field survey rake that was flown on the Propulsion Flight Test Fixture at the NASA Dryden Flight Research Center using the Dryden F-15B research test bed airplane. The objective of this flight test was to ascertain the flow-field angularity, local Mach number profile, total pressure distortion, and dynamic pressure at the aerodynamic interface plane of the Channeled Centerbody Inlet Experiment. This new mixed-compression, supersonic inlet is planned for flight test in the near term. Knowledge of the flow-field characteristics at this location underneath the airplane is essential to flight test planning and computational modeling of the new inlet, anairplane, flying at a free-stream Mach number of 1.65 and a pressure altitude of 40,000 ft, would achieve the desired local Mach number for the future inlet flight test. Interface plane distortion levels of 2 percent and a local angle of attack of -2 deg were observed at this condition. Alternative flight conditions for future testing and an exploration of certain anomalous data also are provided.

  14. Generation of µW level plateau harmonics at high repetition rate.

    Science.gov (United States)

    Hädrich, S; Krebs, M; Rothhardt, J; Carstens, H; Demmler, S; Limpert, J; Tünnermann, A

    2011-09-26

    The process of high harmonic generation allows for coherent transfer of infrared laser light to the extreme ultraviolet spectral range opening a variety of applications. The low conversion efficiency of this process calls for optimization or higher repetition rate intense ultrashort pulse lasers. Here we present state-of-the-art fiber laser systems for the generation of high harmonics up to 1 MHz repetition rate. We perform measurements of the average power with a calibrated spectrometer and achieved µW harmonics between 45 nm and 61 nm (H23-H17) at a repetition rate of 50 kHz. Additionally, we show the potential for few-cycle pulses at high average power and repetition rate that may enable water-window harmonics at unprecedented repetition rate. © 2011 Optical Society of America

  15. Effectiveness of high interest rate policy on exchange rates: A reexamination of the Asian financial crisis

    Directory of Open Access Journals (Sweden)

    Chin Diew Lai

    2006-09-01

    Full Text Available One of the most controversial issues in the aftermath of the Asian financial crisis has been the appropriate response of monetary policy to a sharp decline in the value of some currencies. In this paper, we empirically examine the effects on Asian exchange rates of sharply higher interest rates during the Asian financial crisis. Taking account of the currency contagion effect, our results indicate that sharply higher interest rates helped to support the exchange rates of South Korea, the Philippines, and Thailand. For Malaysia, no significant causal relation is found from the rate of interest to exchange rates, as the authorities in Malaysia did not actively adopt a high interest rate policy to defend the currency.

  16. High repetition rate, high energy, actively Q-switched all-in-fiber laser

    Science.gov (United States)

    Lecourt, J. B.; Bertrand, A.; Guillemet, S.; Hernandez, Y.; Giannone, D.

    2010-05-01

    We report an actively Q-switched Ytterbium-doped all-in-fibre laser delivering 10ns pulses with high repetition rate (from 100kHz to 1MHz). The laser operation has been validated at three different wavelengths (1040, 1050 and 1064nm). The laser can deliver up to 20Watts average power with an high beam quality (M2 = 1).

  17. Planar laser-induced fluorescence fuel imaging during gas-turbine relight

    DEFF Research Database (Denmark)

    Read, Robert; Rogerson, J.W.; Hochgreb, S.

    2013-01-01

    of ignition when the airflow rate is high. In the presence of flame, medium-sized burning droplets are observed close to the injector centerline. Flame interference resulting from fluorescence of polycyclic aromatic hydrocarbons is apparent, but small, suggesting that kerosene planar laser...

  18. Radiative recombination of highly charged ions: Enhanced rates at low energies

    International Nuclear Information System (INIS)

    Frank, A.; Mueller, A.; Haselbauer, J.; Schennach, S.; Spies, W.; Uwira, O.; Wagner, M.

    1992-01-01

    In a single-pass merged-beams experiment employing a dense cold electron target recombination of highly charged ions is studied. Unexpected high recombination rates are observed at low energies E cm in the electron-ion center-of-mass frame. In particular, theoretical estimates for radiative recombination are dramatically exceeded by the experimental recombination rates at E cm =0 eV for U 28+ and for Au 25+ ions. Considerable rate enhancement is also observed for Ar 15+ . This points to a general phenomenon which has to be interpreted as a consequence of high electron densities, low electron beam temperatures, high ion charge states and presence of strong magnetic fields. (orig.)

  19. Miniaturized Stretchable and High-Rate Linear Supercapacitors

    Science.gov (United States)

    Zhu, Wenjun; Zhang, Yang; Zhou, Xiaoshuang; Xu, Jiang; Liu, Zunfeng; Yuan, Ningyi; Ding, Jianning

    2017-07-01

    Linear stretchable supercapacitors have attracted much attention because they are well suited to applications in the rapidly expanding field of wearable electronics. However, poor conductivity of the electrode material, which limits the transfer of electrons in the axial direction of the linear supercapacitors, leads to a serious loss of capacity at high rates. To solve this problem, we use gold nanoparticles to decorate aligned multiwall carbon nanotube to fabricate stretchable linear electrodes. Furthermore, we have developed fine stretchable linear supercapacitors, which exhibited an extremely high elasticity up to 400% strain with a high capacitance of about 8.7 F g-1 at the discharge current of 1 A g-1.

  20. How Did Successful High Schools Improve Their Graduation Rates?

    Science.gov (United States)

    Robertson, Janna Siegel; Smith, Robert W.; Rinka, Jason

    2016-01-01

    The researchers surveyed 23 North Carolina high schools that had markedly improved their graduation rates over the past five years. The administrators reported on the dropout prevention practices and programs to which they attributed their improved graduation rates. The majority of schools reported policy changes, especially with suspension. The…

  1. Call-centre occupant response to new and used filters at two outdoor air supply rates

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Wyon, David; Nielsen, J.

    2002-01-01

    A 2x2 replicaterd field intervention experiment was conducted in a call-centre providing a public telephone directory service: outdoor air supply rate was 8% or 80% of the total airflow of 430 L/s providing 3.5 h-1; and the supply air filters were either new or used (i.e. used in place for 6 mont......). Each of these 4 conditions was maintained for a full working week at a time. Room temperature and humidity averaged 24 deg.C and 27% RH. The 26 operators were blind to conditions and assessed perceived air quality (PAQ), the intensity of Sick Building Syndrome (SBS) symnptoms and self...

  2. Achieving high mobility ZnO : Al at very high growth rates by dc filtered cathodic arc deposition

    International Nuclear Information System (INIS)

    Mendelsberg, R J; Lim, S H N; Wallig, J; Anders, A; Zhu, Y K; Milliron, D J

    2011-01-01

    Achieving a high growth rate is paramount for making large-area transparent conducting oxide coatings at a low cost. Unfortunately, the quality of thin films grown by most techniques degrades as the growth rate increases. Filtered dc cathodic arc is a lesser known technique which produces a stream of highly ionized plasma, in stark contrast to the neutral atoms produced by standard sputter sources. Ions bring a large amount of potential energy to the growing surface which is in the form of heat, not momentum. By minimizing the distance from cathode to substrate, the high ion flux gives a very high effective growth temperature near the film surface without causing damage from bombardment. The high surface temperature is a direct consequence of the high growth rate and allows for high-quality crystal growth. Using this technique, 500-1300 nm thick and highly transparent ZnO : Al films were grown on glass at rates exceeding 250 nm min -1 while maintaining resistivity below 5 x 10 -4 Ω cm with electron mobility as high as 60 cm 2 V -1 s -1 . (fast track communication)

  3. High dose rate endobronchial brachytherapy - treatment technique

    International Nuclear Information System (INIS)

    Carvalho, Heloisa de Andrade; Aisen, Salim; Haddad, Cecilia Maria Kalil; Nadalin, Wladimir; Pedreira Junior, Wilson Leite; Chavantes, Maria Cristina

    1998-01-01

    High dose rate endobronchial brachytherapy is efficient in symptom relief due to obstructive endobronchial malignancies. However, it's role in survival improvement for patients with lung cancer is not yet established. The use of this treatment in increasing, specially in the developing countries. The purpose of this paper is to present the treatment technique used in the Radiotherapy Department of the Hospital da Clinicas, University of Sao Paulo, based on an experience of 60 cases treated with 180 procedures. Some practical suggestions and rules adopted in the Department are described. The severe complications rate is 6.7%, demonstrating an adequate patient selection associated with the technique utilized. (author)

  4. Numerical Simulation of the Application of Solar Radiant Systems, Internal Airflow and Occupants’ Presence in the Improvement of Comfort in Winter Conditions

    Directory of Open Access Journals (Sweden)

    Eusébio Z. E. Conceição

    2016-09-01

    Full Text Available In this work, the use of numerical simulation in the application of solar radiant systems, internal airflow and occupants’ presence in the improvement of comfort in winter conditions is made. The thermal comfort, the local thermal discomfort and the air quality in an occupied chamber space are evaluated. In the experimental measurements, a wood chamber, a desk, two seats, two seated hygro-thermal manikins, a warm radiant floor, a solar radiation simulator and a water solar collector are used. The air velocity and the air temperature fluctuation are experimentally evaluated around 15 human body sections. The chamber surface temperature is experimentally measured. In the numerical simulation, a coupling human thermal comfort (HTC integral model, a computational fluids dynamics (CFD differential model and a building thermal response (BTR integral model are applied. The human thermal comfort level is evaluated by the HTC numerical model. The airflow inside the virtual chamber, using the k-epsilon and RNG turbulence models, is evaluated by the CFD numerical model. The chamber surface and the collector temperatures are evaluated by the BTR numerical model. In the human thermal comfort level, in non-uniform environments, the predicted mean vote (PMV and the predicted percentage of dissatisfied (PPD people are numerically evaluated; in the local thermal discomfort level the draught risk (DR is experimentally and numerically analyzed; and in the air quality, the carbon dioxide CO2 concentration is numerically calculated. In the validation tests, the experimental and numerical values of the chamber surface temperature, the air temperature, the air velocity, the air turbulence intensity and the DR are presented.

  5. Chronic airflow limitation in a rural Indian population: etiology and relationship to body mass index

    Directory of Open Access Journals (Sweden)

    Chakrabarti B

    2011-10-01

    Full Text Available Biswajit Chakrabarti1, Sabita Purkait2, Punyabrata Gun2, Vicky C Moore3, Samadrita Choudhuri4, MJ Zaman5,6, Christopher J Warburton1, Peter MA Calverley7, Rahul Mukherjee3 1Aintree Chest Centre, University Hospital Aintree, Liverpool, UK; 2Moitri Swasthya Kendra, Shramajibi Swasthya Udyog, Chengail, West Bengal, India; 3Department of Respiratory Medicine and Physiology, Birmingham Heartlands Hospital, Birmingham, UK; 4National Medical College, Birgunj, Nepal; 5Department of Epidemiology and Public Health, University College, London, UK; 6The George Institute for Global Health, Sydney, Australia; 7Clinical Sciences Centre, University Hospital Aintree, Liverpool, UK Purpose: Respiratory conditions remain a source of morbidity globally. As such, this study aimed to explore factors associated with the development of airflow obstruction (AFO in a rural Indian setting and, using spirometry, study whether underweight is linked to AFO. Methods: Patients > 35 years old attending a rural clinic in West Bengal, India, took a structured questionnaire, had their body mass index (BMI measured, and had spirometry performed by an ancillary health care worker. Results: In total, 416 patients completed the study; spirometry was acceptable for analysis of forced expiratory volume in 1 second in 286 cases (69%; 16% were noted to exhibit AFO. Factors associated with AFO were: increasing age (95% confidence interval (CI 0.004–0.011; P = 0.005, smoking history (95% CI 0.07–0.174; P = 0.006, male gender (95% CI 0.19–0.47; P = 0.012, reduced BMI (95% CI 0.19–0.65; P = 0.02, and occupation (95% CI 0.12–0.84; P = 0.08. The mean BMI in males who currently smoked (n = 60; 19.29 kg/m2; standard deviation [SD] 3.46 was significantly lower than in male never smokers (n = 33; 21.15 kg/m2 SD 3.38; P < 0.001. AFO was observed in 27% of subjects with a BMI <18.5 kg/m2, falling to 13% with a BMI ≥18.5 kg/m2 (P = 0.013. AFO was observed in 11% of housewives, 22% of farm

  6. Chronic bronchitis and current smoking are associated with more goblet cells in moderate to severe COPD and smokers without airflow obstruction.

    Directory of Open Access Journals (Sweden)

    Victor Kim

    Full Text Available Goblet cell hyperplasia is a classic but variable pathologic finding in COPD. Current literature shows that smoking is a risk factor for chronic bronchitis but the relationship of these clinical features to the presence and magnitude of large airway goblet cell hyperplasia has not been well described. We hypothesized that current smokers and chronic bronchitics would have more goblet cells than nonsmokers or those without chronic bronchitis (CB, independent of airflow obstruction.We recruited 15 subjects with moderate to severe COPD, 12 healthy smokers, and 11 healthy nonsmokers. Six endobronchial mucosal biopsies per subject were obtained by bronchoscopy and stained with periodic acid Schiff-Alcian Blue. Goblet cell density (GCD was quantified as goblet cell number per millimeter of basement membrane. Mucin volume density (MVD was quantified as volume of mucin per unit area of basement membrane.Healthy smokers had a greater GCD and MVD than nonsmokers and COPD subjects. COPD subjects had a greater GCD than nonsmokers. When current smokers (healthy smokers and COPD current smokers, n = 19 were compared with all nonsmokers (nonsmoking controls and COPD ex-smokers, n = 19, current smokers had a greater GCD and MVD. When those with CB (n = 12 were compared to those without CB (n = 26, the CB group had greater GCD. This finding was also seen in those with CB in the COPD group alone. In multivariate analysis, current smoking and CB were significant predictors of GCD using demographics, lung function, and smoking pack years as covariates. All other covariates were not significant predictors of GCD or MVD.Current smoking is associated with a more goblet cell hyperplasia and number, and CB is associated with more goblet cells, independent of the presence of airflow obstruction. This provides clinical and pathologic correlation for smokers with and without COPD.

  7. Chronic Bronchitis and Current Smoking Are Associated with More Goblet Cells in Moderate to Severe COPD and Smokers without Airflow Obstruction

    Science.gov (United States)

    Kim, Victor; Oros, Michelle; Durra, Heba; Kelsen, Steven; Aksoy, Mark; Cornwell, William D.; Rogers, Thomas J.; Criner, Gerard J.

    2015-01-01

    Background Goblet cell hyperplasia is a classic but variable pathologic finding in COPD. Current literature shows that smoking is a risk factor for chronic bronchitis but the relationship of these clinical features to the presence and magnitude of large airway goblet cell hyperplasia has not been well described. We hypothesized that current smokers and chronic bronchitics would have more goblet cells than nonsmokers or those without chronic bronchitis (CB), independent of airflow obstruction. Methods We recruited 15 subjects with moderate to severe COPD, 12 healthy smokers, and 11 healthy nonsmokers. Six endobronchial mucosal biopsies per subject were obtained by bronchoscopy and stained with periodic acid Schiff-Alcian Blue. Goblet cell density (GCD) was quantified as goblet cell number per millimeter of basement membrane. Mucin volume density (MVD) was quantified as volume of mucin per unit area of basement membrane. Results Healthy smokers had a greater GCD and MVD than nonsmokers and COPD subjects. COPD subjects had a greater GCD than nonsmokers. When current smokers (healthy smokers and COPD current smokers, n = 19) were compared with all nonsmokers (nonsmoking controls and COPD ex-smokers, n = 19), current smokers had a greater GCD and MVD. When those with CB (n = 12) were compared to those without CB (n = 26), the CB group had greater GCD. This finding was also seen in those with CB in the COPD group alone. In multivariate analysis, current smoking and CB were significant predictors of GCD using demographics, lung function, and smoking pack years as covariates. All other covariates were not significant predictors of GCD or MVD. Conclusions Current smoking is associated with a more goblet cell hyperplasia and number, and CB is associated with more goblet cells, independent of the presence of airflow obstruction. This provides clinical and pathologic correlation for smokers with and without COPD. PMID:25646735

  8. Inverse methods for the mechanical characterization of materials at high strain rates

    Directory of Open Access Journals (Sweden)

    Casas-Rodriguez J.P.

    2012-08-01

    Full Text Available Mechanical material characterization represents a research challenge. Furthermore, special attention is directed to material characterization at high strain rates as the mechanical properties of some materials are influenced by the rate of loading. Diverse experimental techniques at high strain rates are available, such as the drop-test, the Taylor impact test or the Split Hopkinson pressure bar among others. However, the determination of the material parameters associated to a given mathematical constitutive model from the experimental data is a complex and indirect problem. This paper presents a material characterization methodology to determine the material parameters of a given material constitutive model from a given high strain rate experiment. The characterization methodology is based on an inverse technique in which an inverse problem is formulated and solved as an optimization procedure. The input of the optimization procedure is the characteristic signal from the high strain rate experiment. The output of the procedure is the optimum set of material parameters determined by fitting a numerical simulation to the high strain rate experimental signal.

  9. Dynamic tensile fracture of mortar at ultra-high strain-rates

    International Nuclear Information System (INIS)

    Erzar, B.; Buzaud, E.; Chanal, P.-Y.

    2013-01-01

    During the lifetime of a structure, concrete and mortar may be exposed to highly dynamic loadings, such as impact or explosion. The dynamic fracture at high loading rates needs to be well understood to allow an accurate modeling of this kind of event. In this work, a pulsed-power generator has been employed to conduct spalling tests on mortar samples at strain-rates ranging from 2 × 10 4 to 4 × 10 4  s −1 . The ramp loading allowed identifying the strain-rate anytime during the test. A power law has been proposed to fit properly the rate-sensitivity of tensile strength of this cementitious material over a wide range of strain-rate. Moreover, a specimen has been recovered damaged but unbroken. Micro-computed tomography has been employed to study the characteristics of the damage pattern provoked by the dynamic tensile loading

  10. Experimental and Numerical Study of Windage Losses in the Narrow Gap Region of a High-Speed Electric Motor

    Directory of Open Access Journals (Sweden)

    Kevin R. Anderson

    2018-03-01

    Full Text Available Windage (drag losses have been found to be a key design factor for high power density and high-speed electric motor development. Inducing axial flow between rotor and stator is a common method in cooling the rotor. Hence, it is necessary to understand the effect on windage while forced axial airflow is in present in the air gap. The current paper presents results from experimental testing and modeling of a high-speed motor designed to operate at 30,000 revolutions per minute (RPM and utilize axial air cooling of 200 Liters per minute (LPM to cool the motor. Details of the experimental apparatus and computational fluid dynamics (CFD modeling of the small gap narrow region of the stator/rotor are outlined in the paper. The experimental results are used to calibrate the CFD model. Results for windage losses, flow rate of cooling air, power and torque of the motor versus mass flow rate are given in the paper. Trade studies of CFD on the effect of inlet cooling flow rate, and parasitic heat transfer losses on the Taylor–Couette flow coherent flow structure breakdown are presented. Windage losses on the order of 20 W are found to be present in the configuration tested and simulated.

  11. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  12. Miniaturized Stretchable and High-Rate Linear Supercapacitors.

    Science.gov (United States)

    Zhu, Wenjun; Zhang, Yang; Zhou, Xiaoshuang; Xu, Jiang; Liu, Zunfeng; Yuan, Ningyi; Ding, Jianning

    2017-12-01

    Linear stretchable supercapacitors have attracted much attention because they are well suited to applications in the rapidly expanding field of wearable electronics. However, poor conductivity of the electrode material, which limits the transfer of electrons in the axial direction of the linear supercapacitors, leads to a serious loss of capacity at high rates. To solve this problem, we use gold nanoparticles to decorate aligned multiwall carbon nanotube to fabricate stretchable linear electrodes. Furthermore, we have developed fine stretchable linear supercapacitors, which exhibited an extremely high elasticity up to 400% strain with a high capacitance of about 8.7 F g -1 at the discharge current of 1 A g -1 .

  13. High-Strain Rate Failure Modeling Incorporating Shear Banding and Fracture

    Science.gov (United States)

    2017-11-22

    High Strain Rate Failure Modeling Incorporating Shear Banding and Fracture The views, opinions and/or findings contained in this report are those of...SECURITY CLASSIFICATION OF: 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 13. SUPPLEMENTARY NOTES 12. DISTRIBUTION AVAILIBILITY STATEMENT 6. AUTHORS...Report as of 05-Dec-2017 Agreement Number: W911NF-13-1-0238 Organization: Columbia University Title: High Strain Rate Failure Modeling Incorporating

  14. High freight rates hinder oil markets' return to equilibrium

    International Nuclear Information System (INIS)

    Anon

    2005-01-01

    Hurricane damage to refineries in the US has created shortages of refined products there, boosting imports and sending freight rates across the Atlantic to record levels. The situation was made worse for a time by a strike at France's main oil terminals in the Mediterranean, which prevented some oil tankers from being rapidly redeployed to routes across the Atlantic. Worldscale (WS) rates for routes from the UK and Europe to the US Atlantic and Gulf Coasts rose well above WS500 for clean tonnage during October. High rates were nevertheless not simply confined to product tankers crossing the Atlantic. Rates for crude tankers to the US have also risen, and tightness has begun to appear in some other markets as well. The net result has been to slow down the movement of oil from regions of surplus to those of scarcity, depressing prices in the former and keeping them at high levels in the latter. Atlantic tanker markets look like remaining tight for the rest of the year and perhaps beyond. (author)

  15. Brittle materials at high-loading rates: an open area of research

    Science.gov (United States)

    Forquin, Pascal

    2017-01-01

    Brittle materials are extensively used in many civil and military applications involving high-strain-rate loadings such as: blasting or percussive drilling of rocks, ballistic impact against ceramic armour or transparent windshields, plastic explosives used to damage or destroy concrete structures, soft or hard impacts against concrete structures and so on. With all of these applications, brittle materials are subjected to intense loadings characterized by medium to extremely high strain rates (few tens to several tens of thousands per second) leading to extreme and/or specific damage modes such as multiple fragmentation, dynamic cracking, pore collapse, shearing, mode II fracturing and/or microplasticity mechanisms in the material. Additionally, brittle materials exhibit complex features such as a strong strain-rate sensitivity and confining pressure sensitivity that justify expending greater research efforts to understand these complex features. Currently, the most popular dynamic testing techniques used for this are based on the use of split Hopkinson pressure bar methodologies and/or plate-impact testing methods. However, these methods do have some critical limitations and drawbacks when used to investigate the behaviour of brittle materials at high loading rates. The present theme issue of Philosophical Transactions A provides an overview of the latest experimental methods and numerical tools that are currently being developed to investigate the behaviour of brittle materials at high loading rates. This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'.

  16. Flashing motor at high transition rate

    International Nuclear Information System (INIS)

    Ai Baoquan; Wang Liqiu; Liu Lianggang

    2007-01-01

    The movement of a Brownian particle in a fluctuating two-state periodic potential is investigated. At high transition rate, we use a perturbation method to obtain the analytical solution of the model. It is found that the net current is a peaked function of thermal noise, barrier height and the fluctuation ratio between the two states. The thermal noise may facilitate the directed motion at a finite intensity. The asymmetry parameter of the potential is sensitive to the direction of the net current

  17. Mechanical characterization of rocks at high strain rate

    Directory of Open Access Journals (Sweden)

    Konstantinov A.

    2012-08-01

    Full Text Available The paper presents the dynamic characterization in tension and compression of three rocks, Carrara marble, Onsernone gneiss and Peccia Marble, at high strain-rates. Two versions of a Split Hopkinson Bar have been used. The version for direct tension tests is installed at the DynaMat Laboratory of the University of Applied Sciences of Southern Switzerland, while the traditional version in compression is installed at the Laboratory of Dynamic Investigation of Materials of Lobachevsky State University. Results of the tests show a significantly strain-rate sensitive behaviour, exhibiting dynamic strength increasing with strain-rate. The experimental research has been developed in the frame of the Swiss-Russian Joint Research Program.

  18. Trends in pharmacotherapy for chronic airflow limitation in Argentina: 1992-2002 Tendencias en el tratamiento farmacológico de la obstrucción crónica al flujo aéreo en Argentina: 1992-2002

    Directory of Open Access Journals (Sweden)

    Néstor A. Molfino

    2004-10-01

    Full Text Available Asthma and COPD mortality rates have decreased in Argentina. These trends might be the result of the way these conditions are being treated. The number of units for prescription and over-the-counter (OTC drugs used to treat chronic airflow limitation in Argentina from 1992 through 2002 were analyzed. Units for drugs to treat chronic airflow limitation fell by 45% over the 11-year period (p Las tasas de mortalidad por asma y enfermedad pulmonar obstructiva crónica (EPOC se han reducido en Argentina. Estas tendencias pueden deberse a la forma en que tales enfermedades son tratadas. Se analizaron los medicamentos utilizados para el tratamiento del asma y EPOC desde 1992 hasta el año 2002. El total de unidades utilizadas cayó un 45% (p = 0.0001 debido a una reducción significativa de los agonistas orales b2 (83%, las teofilinas (74% los esteroides orales (66% y los agonistas inhalados b2 de acción corta (28%. La fracción de mercado de los esteroides inhalados aumentó del 2.6% al 11.7%, en el caso de ipratropio del 0.35% al 3.7%, la combinación de esteroides inhalados y agonistas b2 de acción corta aumentaron del 7.8% al 13% y la combinación de ipratropio con agonistas inhalados b2 de acción corta aumentó del 1.7% al 7.3%. Los agonistas inhalados b2 de acción prolongada y los antileukotrienos fueron recetados raramente en el período analizado. El uso de terapias más específicas (esteroides inhalados e ipratropio aumentó significativamente de acuerdo con las recomendaciones para el tratamiento del asma y EPOC y esto podría explicar las reducciones en las tasas de mortalidad de estas enfermedades.

  19. High rate loading tests and impact tests of concrete and reinforcement

    International Nuclear Information System (INIS)

    Takeda, J.I.; Tachikawa, H.; Fujimoto, K.

    1982-01-01

    The responses of reinforced concrete structural members and structures subjected to impact or impulsive loadings are affected by the behavior of constituent concrete and reinforcement which are the synthesis of the rate effects and the contribution of propagating stress waves of them. The rate effects and the contribution of stress waves do not have the same tendency in the variation of magnitude of them with speed of impact or impulsive loadings. Therefore the rate effects, mentioned above, should be obtained by the tests minimized the effect of stress waves (high rate loading test). This paper deals with the testing techniques with high rate loadings and impact, and also reports the main results of these tests. (orig.) [de

  20. High Strain Rate Tensile Testing of Silver Nanowires: Rate-Dependent Brittle-to-Ductile Transition.

    Science.gov (United States)

    Ramachandramoorthy, Rajaprakash; Gao, Wei; Bernal, Rodrigo; Espinosa, Horacio

    2016-01-13

    The characterization of nanomaterials under high strain rates is critical to understand their suitability for dynamic applications such as nanoresonators and nanoswitches. It is also of great theoretical importance to explore nanomechanics with dynamic and rate effects. Here, we report in situ scanning electron microscope (SEM) tensile testing of bicrystalline silver nanowires at strain rates up to 2/s, which is 2 orders of magnitude higher than previously reported in the literature. The experiments are enabled by a microelectromechanical system (MEMS) with fast response time. It was identified that the nanowire plastic deformation has a small activation volume (ductile failure mode transition was observed at a threshold strain rate of 0.2/s. Transmission electron microscopy (TEM) revealed that along the nanowire, dislocation density and spatial distribution of plastic regions increase with increasing strain rate. Furthermore, molecular dynamic (MD) simulations show that deformation mechanisms such as grain boundary migration and dislocation interactions are responsible for such ductility. Finally, the MD and experimental results were interpreted using dislocation nucleation theory. The predicted yield stress values are in agreement with the experimental results for strain rates above 0.2/s when ductility is pronounced. At low strain rates, random imperfections on the nanowire surface trigger localized plasticity, leading to a brittle-like failure.

  1. Disposable Electronic Cigarettes and Electronic Hookahs: Evaluation of Performance

    Science.gov (United States)

    Williams, Monique; Ghai, Sanjay

    2015-01-01

    Introduction: The purpose of this study was to characterize the performance of disposable button-activated and disposable airflow-activated electronic cigarettes (EC) and electronic hookahs (EH). Methods: The airflow rate required to produce aerosol, pressure drop, and the aerosol absorbance at 420nm were measured during smoke-outs of 9 disposable products. Three units of each product were tested in these experiments. Results: The airflow rates required to produce aerosol and the aerosol absorbances were lower for button-activated models (3mL/s; 0.41–0.55 absorbance) than for airflow-activated models (7–17mL/s; 0.48–0.84 absorbance). Pressure drop was also lower across button-activated products (range = 6–12mm H2O) than airflow-activated products (range = 15–67mm H20). For 25 of 27 units tested, airflow did not have to be increased during smoke-out to maintain aerosol production, unlike earlier generation models. Two brands had uniform performance characteristics for all parameters, while 3 had at least 1 product that did not function normally. While button-activated models lasted 200 puffs or less and EH airflow-activated models often lasted 400 puffs, none of the models produced as many puffs as advertised. Puff number was limited by battery life, which was shorter in button-activated models. Conclusion: The performance of disposable products was differentiated mainly by the way the aerosol was produced (button vs airflow-activated) rather than by product type (EC vs EH). Users needed to take harder drags on airflow-activated models. Performance varied within models, and battery life limited the number of puffs. Data suggest quality control in manufacturing varies among brands. PMID:25104117

  2. Activated carbon derived from melaleuca barks for outstanding high-rate supercapacitors

    Science.gov (United States)

    Luo, Qiu-Ping; Huang, Liang; Gao, Xiang; Cheng, Yongliang; Yao, Bin; Hu, Zhimi; Wan, Jun; Xiao, Xu; Zhou, Jun

    2015-07-01

    Activated carbon (AC) was prepared via carbonizing melaleuca bark in an argon atmosphere at 600 °C followed with KOH activation for high-rate supercapacitors. This AC electrode has a high capacitance of 233 F g-1 at a scan rate of 2 mV s-1 and an excellent rate capability of ˜80% when increasing the sweep rate from 2 to 500 mV s-1. The symmetric supercapacitor assembled by the above electrode can deliver a high energy density of 4.2 Wh kg-1 with a power density of 1500 W kg-1 when operated in the voltage range of 0-1 V in 1 M H2SO4 aqueous electrolyte while maintaining great cycling stability (less than 5% capacitance loss after 10 000 cycles at sweep rate of 100 mV s-1). All the outstanding electrochemical performances make this AC electrode a promising candidate for potential energy storage application.

  3. High repetition rate intense ion beam source

    International Nuclear Information System (INIS)

    Hammer, D.A.; Glidden, S.C.; Noonan, B.

    1992-01-01

    This final report describes a ≤ 150kV, 40kA, 100ns high repetition rate pulsed power system and intense ion beam source which is now in operation at Cornell University. Operation of the Magnetically-controlled Anode Plasma (MAP) ion diode at > 100Hz (burst mode for up to 10 pulse bursts) provides an initial look at repetition rate limitations of both the ion diode and beam diagnostics. The pulsed power systems are capable of ≥ 1kHz operation (up to 10 pulse bursts), but ion diode operation was limited to ∼100Hz because of diagnostic limitations. By varying MAP diode operating parameters, ion beams can be extracted at a few 10s of keV or at up to 150keV, the corresponding accelerating gap impedance ranging from about 1Ω to about 10Ω. The ability to make hundreds of test pulses per day at an average repetition rate of about 2 pulses per minute permits statistical analysis of diode operation as a function of various parameters. Most diode components have now survived more than 10 4 pulses, and the design and construction of the various pulsed power components of the MAP diode which have enabled us to reach this point are discussed. A high speed data acquisition system and companion analysis software capable of acquiring pulse data at 1ms intervals (in bursts of up to 10 pulses) and processing it in ≤ min is described

  4. U.S. High School Graduation Rates: Patterns and Explanations

    OpenAIRE

    Richard J. Murnane

    2013-01-01

    I survey the evidence on patterns in U.S. high school graduation rates over the period 1970–2010 and report the results of new research conducted to fill in holes in the evidence. I begin by pointing out the strengths and limitations of existing data sources. I then describe six striking patterns in graduation rates. They include stagnation over the last three decades of the twentieth century, significant race-, income-, and gender-based gaps, and significant increases in graduation rates o...

  5. Predicting High Frequency Exchange Rates using Machine Learning

    OpenAIRE

    Palikuca, Aleksandar; Seidl,, Timo

    2016-01-01

    This thesis applies a committee of Artificial Neural Networks and Support Vector Machines on high-dimensional, high-frequency EUR/USD exchange rate data in an effort to predict directional market movements on up to a 60 second prediction horizon. The study shows that combining multiple classifiers into a committee produces improved precision relative to the best individual committee members and outperforms previously reported results. A trading simulation implementing the committee classifier...

  6. Preliminary study of ammonia emissions from naturally ventilated fattening pig houses in the south-east China

    Energy Technology Data Exchange (ETDEWEB)

    Wang, K.; Ye, Z.; Li, H. [Zhejiang Univ., Hangzhou City (China). School of Biosystems Engineering and Food Science

    2010-07-01

    This paper reported on an experimental simulation in which ammonia emissions from naturally ventilated pig houses were monitored and the ventilation airflow rate was estimated. Two identical pig houses and the same number of pigs were used in the study. Natural ventilation was used in the experimental pig house while the reference pig house had mechanical ventilation. Both houses had the same air temperature and relative humidity. The ventilation airflow rate of the experimental pig house was estimated by calculating the ventilation airflow rate in the reference pig house. The ventilation airflow rate of the experimental pig house was also estimated based on heat pressure theory. The room air temperature and relative humidity were found to be related to inlet air temperature and relative humidity for both ventilation systems. After 19 days, the average air temperature in the room with mechanical ventilation was about 4.1 degrees C higher than inlet air temperature, but the relative humidity was lower by 7.1 per cent. In the room with natural ventilation, the average air temperature after 19 days was about 3.9 degrees C higher than inlet air temperature, but the relative humidity was lower by 4.3 per cent.

  7. Measurement and Modelling of Air Flow Rate in a Naturally Ventilated Double Skin Facade

    DEFF Research Database (Denmark)

    Heiselberg, Per; Kalyanova, Olena; Jensen, Rasmus Lund

    2008-01-01

    Air flow rate in a naturally ventilated double skin façade (DSF) is extremely difficult to measure due to the stochastic nature of wind, and as a consequence non-uniform and dynamic flow conditions. This paper describes the results of two different methods to measure the air flow in a full...... by the thermal simulation program, BSim, based on measured weather boundary conditions are compared to the measured air temperature, temperature gradient and mass flow rate in the DSF cavity. The results show that it is possible to predict the temperature distribution and airflow in the DSF although some......-scale outdoor test facility with a naturally ventilated double skin façade. Although both methods are difficult to use under such dynamic air flow conditions, they show reasonable agreement and can be used for experimental validation of numerical models of natural ventilation air flow in DSF. Simulations...

  8. A copper bromide vapour laser with a high pulse repetition rate

    International Nuclear Information System (INIS)

    Shiyanov, D V; Evtushenko, Gennadii S; Sukhanov, V B; Fedorov, V F

    2002-01-01

    The results of an experimental study of a copper bromide vapour laser with a discharge-channel diameter above 2.5 cm and a high pump-pulse repetition rate are presented. A TGU1-1000/25 high-power tacitron used as a switch made it possible to obtain for the first time a fairly high output radiation power for pump-pulse repetition rates exceeding 200 kHz. At a maximum pump-pulse repetition rate of 250 kHz achieved in a laser tube 2.6 cm in diameter and 76 cm long, the output power was 1.5 W. The output powers of 3 and 10.5 W were reached for pump-pulse repetition rates of 200 and 100 kHz, respectively. These characteristics were obtained without circulating a buffer gas and (or) low-concentration active impurities through the active volume. (active media. lasers)

  9. Split-Hopkinson Pressure Bar: an experimental technique for high strain rate tests

    International Nuclear Information System (INIS)

    Sharma, S.; Chavan, V.M.; Agrawal, R.G.; Patel, R.J.; Kapoor, R.; Chakravartty, J.K.

    2011-06-01

    Mechanical properties of materials are, in general, strain rate dependent, i.e. they respond differently at quasi-static and higher strain rate condition. The Split-Hopkinson Pressure Bar (SHPB), also referred to as Kolsky bar is a commonly used setup for high strain rate testing. SHPB is suitable for high strain rate test in strain rate range of 10 2 to 10 4 s -1 . These high strain rate data are required for safety and structural integrity assessment of structures subjected to dynamic loading. As high strain rate data are not easily available in open literature need was felt for setting up such high strain rate testing machine. SHPB at BARC was designed and set-up inhouse jointly by Refuelling Technology Division and Mechanical Metallurgy Division, at Hall no. 3, BARC. A number of conceptual designs for SHPB were thought of and the optimized design was worked out. The challenges of precision tolerance, straightness in bars and design and proper functioning of pneumatic gun were met. This setup has been used extensively to study the high strain rate material behavior. This report introduces the SHPB in general and the setup at BARC in particular. The history of development of SHPB, the basic formulations of one dimensional wave propagation, the relations between the wave velocity, particle velocity and elastic strain in a one dimensional bar, and the equations used to obtain the final stress vs. strain curves are described. The calibration of the present setup, the pre-test calculations and the posttest analysis of data are described. Finally some of the experimental results on different materials such as Cu, SS305, SA516 and Zr, at room temperature and elevated temperatures are presented. (author)

  10. Particle loading rates for HVAC filters, heat exchangers, and ducts.

    Science.gov (United States)

    Waring, M S; Siegel, J A

    2008-06-01

    The rate at which airborne particulate matter deposits onto heating, ventilation, and air-conditioning (HVAC) components is important from both indoor air quality (IAQ) and energy perspectives. This modeling study predicts size-resolved particle mass loading rates for residential and commercial filters, heat exchangers (i.e. coils), and supply and return ducts. A parametric analysis evaluated the impact of different outdoor particle distributions, indoor emission sources, HVAC airflows, filtration efficiencies, coils, and duct system complexities. The median predicted residential and commercial loading rates were 2.97 and 130 g/m(2) month for the filter loading rates, 0.756 and 4.35 g/m(2) month for the coil loading rates, 0.0051 and 1.00 g/month for the supply duct loading rates, and 0.262 g/month for the commercial return duct loading rates. Loading rates are more dependent on outdoor particle distributions, indoor sources, HVAC operation strategy, and filtration than other considered parameters. The results presented herein, once validated, can be used to estimate filter changing and coil cleaning schedules, energy implications of filter and coil loading, and IAQ impacts associated with deposited particles. The results in this paper suggest important factors that lead to particle deposition on HVAC components in residential and commercial buildings. This knowledge informs the development and comparison of control strategies to limit particle deposition. The predicted mass loading rates allow for the assessment of pressure drop and indoor air quality consequences that result from particle mass loading onto HVAC system components.

  11. Effect of hole geometry and Electric-Discharge Machining (EDM) on airflow rates through small diameter holes in turbine blade material

    Science.gov (United States)

    Hippensteele, S. A.; Cochran, R. P.

    1980-01-01

    The effects of two design parameters, electrode diameter and hole angle, and two machine parameters, electrode current and current-on time, on air flow rates through small-diameter (0.257 to 0.462 mm) electric-discharge-machined holes were measured. The holes were machined individually in rows of 14 each through 1.6 mm thick IN-100 strips. The data showed linear increase in air flow rate with increases in electrode cross sectional area and current-on time and little change with changes in hole angle and electrode current. The average flow-rate deviation (from the mean flow rate for a given row) decreased linearly with electrode diameter and increased with hole angle. Burn time and finished hole diameter were also measured.

  12. Uncertainties in neural network model based on carbon dioxide concentration for occupancy estimation

    Energy Technology Data Exchange (ETDEWEB)

    Alam, Azimil Gani; Rahman, Haolia; Kim, Jung-Kyung; Han, Hwataik [Kookmin University, Seoul (Korea, Republic of)

    2017-05-15

    Demand control ventilation is employed to save energy by adjusting airflow rate according to the ventilation load of a building. This paper investigates a method for occupancy estimation by using a dynamic neural network model based on carbon dioxide concentration in an occupied zone. The method can be applied to most commercial and residential buildings where human effluents to be ventilated. An indoor simulation program CONTAMW is used to generate indoor CO{sub 2} data corresponding to various occupancy schedules and airflow patterns to train neural network models. Coefficients of variation are obtained depending on the complexities of the physical parameters as well as the system parameters of neural networks, such as the numbers of hidden neurons and tapped delay lines. We intend to identify the uncertainties caused by the model parameters themselves, by excluding uncertainties in input data inherent in measurement. Our results show estimation accuracy is highly influenced by the frequency of occupancy variation but not significantly influenced by fluctuation in the airflow rate. Furthermore, we discuss the applicability and validity of the present method based on passive environmental conditions for estimating occupancy in a room from the viewpoint of demand control ventilation applications.

  13. Precise muon drift tube detectors for high background rate conditions

    Energy Technology Data Exchange (ETDEWEB)

    Engl, Albert

    2011-08-04

    The muon spectrometer of the ATLAS-experiment at the Large Hadron Collider consists of drift tube chambers, which provide the precise measurement of trajectories of traversing muons. In order to determine the momentum of the muons with high precision, the measurement of the position of the muon in a single tube has to be more accurate than {sigma}{<=}100 {mu}m. The large cross section of proton-proton-collisions and the high luminosity of the accelerator cause relevant background of neutrons and {gamma}s in the muon spectrometer. During the next decade a luminosity upgrade to 5.10{sup 34} cm{sup -2}s{sup -1} is planned, which will increase the background counting rates considerably. In this context this work deals with the further development of the existing drift chamber technology to provide the required accuracy of the position measurement under high background conditions. Two approaches of improving the drift tube chambers are described: - In regions of moderate background rates a faster and more linear drift gas can provide precise position measurement without changing the existing hardware. - At very high background rates drift tube chambers consisting of tubes with a diameter of 15 mm are a valuable candidate to substitute the CSC muon chambers. The single tube resolution of the gas mixture Ar:CO{sub 2}:N{sub 2} in the ratio of 96:3:1 Vol %, which is more linear and faster as the currently used drift gas Ar:CO{sub 2} in the ratio of 97:3 Vol %, was determined at the Cosmic Ray Measurement Facility at Garching and at high {gamma}-background counting rates at the Gamma Irradiation Facility at CERN. The alternative gas mixture shows similar resolution without background. At high background counting rates it shows better resolution as the standard gas. To analyse the data the various parts of the setup have to be aligned precisely to each other. The change to an alternative gas mixture allows the use of the existing hardware. The second approach are drift tubes

  14. Decay rate of the false vacuum at high temperatures

    International Nuclear Information System (INIS)

    Eboli, O.J.P.; Marques, G.C.

    1986-01-01

    We investigate, within the semiclassical approach, the high temperature behaviour of the decay rate (Γ) of the metastable vacuum in Field Theory. We exhibit some exactly soluble (1+1) and (3+1) dimensional examples and develop a formal expression for γ in the high temperature limit. (Author) [pt

  15. Inlet-engine matching for SCAR including application of a bicone variable geometry inlet. [Supersonic Cruise Aircraft Research

    Science.gov (United States)

    Wasserbauer, J. F.; Gerstenmaier, W. H.

    1978-01-01

    Airflow characteristics of variable cycle engines (VCE) designed for Mach 2.32 can have transonic airflow requirements as high as 1.6 times the cruise airflow. This is a formidable requirement for conventional, high performance, axisymmetric, translating centerbody mixed compression inlets. An alternate inlet is defined where the second cone of a two cone centerbody collapses to the initial cone angle to provide a large off-design airflow capability, and incorporates modest centerbody translation to minimize spillage drag. Estimates of transonic spillage drag are competitive with those of conventional translating centerbody inlets. The inlet's cruise performance exhibits very low bleed requirements with good recovery and high angle of attack capability.

  16. Inlet-engine matching for SCAR including application of a bicone variable geometry inlet

    Science.gov (United States)

    Wasserbauer, J. F.; Gerstenmaier, W. H.

    1978-01-01

    Airflow characteristics of variable cycle engines (VCE) designed for Mach 2.32 can have transonic airflow requirements as high as 1.6 times the cruise airflow. This is a formidable requirement for conventional, high performance, axisymmetric, translating centerbody mixed compression inlets. An alternate inlet is defined, where the second cone of a two cone center body collapses to the initial cone angle to provide a large off-design airflow capability, and incorporates modest centerbody translation to minimize spillage drag. Estimates of transonic spillage drag are competitive with those of conventional translating centerbody inlets. The inlet's cruise performance exhibits very low bleed requirements with good recovery and high angle of attack capability.

  17. Study of magnetorheological fluids at high shear rates

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaojie; Gordaninejad, Faramarz [University of Nevada, Department of Mechanical Engineering, Reno, NV (United States)

    2006-08-15

    The tunable rheological properties of magnetorheological (MR) materials at high shear rates are studied using a piston-driven flow-mode-type rheometer. The proposed method provides measurement of the apparent viscosity and yield stress of MR fluids for a shear rate range of 50 to 40,000 s{sup -1}. The rheological properties of a commercial MR fluid, as well as a newly developed MR polymeric gel, and a ferrofluid-based MR fluid are investigated. The results for apparent viscosity and dynamic and static shear stresses under different applied magnetic fields are reported. (orig.)

  18. Development of an engineering level prediction method for high angle of attack aerodynamics

    Science.gov (United States)

    Reisenthel, Patrick H.; Rodman, Laura C.; Nixon, David

    1993-01-01

    The present work is concerned with predicting the unsteady flow considered to be the cause of the structural failure of twin vertical tail aircraft. An engineering tool has been produced for high angle of attack aerodynamics using the simplest physical models. The main innovation behind this work is its emphasis on the modeling of two key aspects of the dominant physics associated with high angle-of-attack airflows, namely unsteady separation and vortex breakdown.

  19. On high interest rates in Brazil

    Directory of Open Access Journals (Sweden)

    Francisco Lafaiete Lopes

    2014-03-01

    Full Text Available This article examines the question of why interest rates are so high in Brazil as compared to the international average. It looks at theoretical arguments based on excessive government deficits, structural lack of private savings, inflation bias, excessive investment demand and fear of floating. An informal look at the evidence does not strongly corroborate any of these arguments. Hence a wise central bank should consider "testing" the market to make sure it is not dealing with an extreme equilibrium configuration or a long standing disequilibrium.

  20. Current situation of asthma-COPD overlap syndrome (ACOS) in Chinese patients older than 40 years with airflow limitation: rationale and design for a multicenter, cross-sectional trial (study protocol).

    Science.gov (United States)

    Kang, Jian; Yao, Wanzhen; Cai, Baiqiang; Chen, Ping; Ling, Xia; Shang, Hongyan

    2016-12-01

    Asthma and chronic obstructive pulmonary disease (COPD) are the frequently occurring chronic airway diseases, and the overlapping syndrome observed in the majority of patients has been recently defined as asthma-COPD overlap syndrome (ACOS) by the Global Initiative for Chronic Obstructive Lung (GOLD, 2014) and Global initiative for Asthma (GINA, 2015). The proportion, features, and clinical practice of ACOS still remain elusive in China. We are conducting this multicenter, cross-sectional, observational study (NCT02600221) to investigate the distributions of chronic obstructive diseases in patients >40 years of age with chronic airflow limitation in China along with determination of the main clinical practice and features of these diseases. The study will also explore the factors that may influence the exacerbations and severity of ACOS in Chinese patients (>40 years of age). A total of 2,000 patients (age, ≥40 years; either sex) who are clinically diagnosed as having asthma, COPD/chronic bronchitis/emphysema, or ACOS for at least 12 months with airflow limitation [post-bronchodilator forced expiratory volume in 1 second/forced vital capacity (FEV 1 /FVC): current situation, main clinical practice, and features of ACOS, asthma, and COPD conditions in Chinese patients. The insights will be helpful in designing optimal management strategies for ACOS and redefining the healthcare development programs.

  1. High repetition rate burst-mode spark gap

    International Nuclear Information System (INIS)

    Faltens, A.; Reginato, L.; Hester, R.; Chesterman, A.; Cook, E.; Yokota, T.; Dexter, W.

    1978-01-01

    Results are presented on the design and testing of a pressurized gas blown spark gap switch capable of high repetition rates in a burst mode of operation. The switch parameters which have been achieved are as follows: 220-kV, 42-kA, a five pulse burst at 1-kHz, 12-ns risetime, 2-ns jitter at a pulse width of 50-ns

  2. Brittle materials at high-loading rates: an open area of research

    Science.gov (United States)

    2017-01-01

    Brittle materials are extensively used in many civil and military applications involving high-strain-rate loadings such as: blasting or percussive drilling of rocks, ballistic impact against ceramic armour or transparent windshields, plastic explosives used to damage or destroy concrete structures, soft or hard impacts against concrete structures and so on. With all of these applications, brittle materials are subjected to intense loadings characterized by medium to extremely high strain rates (few tens to several tens of thousands per second) leading to extreme and/or specific damage modes such as multiple fragmentation, dynamic cracking, pore collapse, shearing, mode II fracturing and/or microplasticity mechanisms in the material. Additionally, brittle materials exhibit complex features such as a strong strain-rate sensitivity and confining pressure sensitivity that justify expending greater research efforts to understand these complex features. Currently, the most popular dynamic testing techniques used for this are based on the use of split Hopkinson pressure bar methodologies and/or plate-impact testing methods. However, these methods do have some critical limitations and drawbacks when used to investigate the behaviour of brittle materials at high loading rates. The present theme issue of Philosophical Transactions A provides an overview of the latest experimental methods and numerical tools that are currently being developed to investigate the behaviour of brittle materials at high loading rates. This article is part of the themed issue ‘Experimental testing and modelling of brittle materials at high strain rates’. PMID:27956517

  3. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function.

    Science.gov (United States)

    Coolen, Bram F; Abdurrachim, Desiree; Motaal, Abdallah G; Nicolay, Klaas; Prompers, Jeanine J; Strijkers, Gustav J

    2013-03-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered at will to increase the frame rate because of gradient hardware, spatial resolution, and signal-to-noise limitations. To overcome these limitations associated with electrocardiography-triggered Cine MRI, in this paper, we introduce a retrospectively triggered Cine MRI protocol capable of producing high-resolution high frame rate Cine MRI of the mouse heart for addressing left ventricular diastolic function. Simulations were performed to investigate the influence of MRI sequence parameters and the k-space filling trajectory in relation to the desired number of frames per cardiac cycle. An optimized protocol was applied in vivo and compared with electrocardiography-triggered Cine for which a high-frame rate could only be achieved by several interleaved acquisitions. Retrospective high frame rate Cine MRI proved superior to the interleaved electrocardiography-triggered protocols. High spatial-resolution Cine movies with frames rates up to 80 frames per cardiac cycle were obtained in 25 min. Analysis of left ventricular filling rate curves allowed accurate determination of early and late filling rates and revealed subtle impairments in left ventricular diastolic function of diabetic mice in comparison with nondiabetic mice. Copyright © 2012 Wiley Periodicals, Inc.

  4. A new high rate positron lifetime measurement system

    International Nuclear Information System (INIS)

    Bedwell, M.O.; Paulus, T.J.

    1979-01-01

    Positron lifetime measuring system, a technique to perform non-destructive studies on the internal structure of materials, has many components common to those used for nuclear time spectroscopy systems. In each case, a timing coincidence curve is measured for the energy range of interest, and this is accomplished in a typical timing coincidence system. The paper first describes the conventional timing coincidence system, then a new fast timing system is introduced. Comparing to the conventional fast/slow timing system, the fast timing technique offers reduced complexity, lower system cost, and improved high data rate capability. Experimental results show that the FWHM timing resolution ranges from 190 ps for a 1.1 : 1 dynamic range to 337 ps for a 100 : 1 dynamic range of signals with 60 Co. As for the timing resolution as a function of energy, the FWHM resolution for each channel ranges from 124 ps at 1 MeV to 400 ps at 100 keV. Since the excellent timing performance is maintained even at very high input rate, the experimenters can use much more active sources to increase the true coincidence rate and reduce data accumulation time. This method has the added advantage of minimizing long term drift effects since the experiments can be conducted in less time. (Wakatsuki, Y.)

  5. Twinning in copper deformed at high strain rates

    Indian Academy of Sciences (India)

    Abstract. Copper samples having varying microstructures were deformed at high strain rates using a split-. Hopkinson pressure bar. Transmission electron microscopy results show deformation twins present in samples that were both annealed and strained, whereas samples that were annealed and left unstrained, as well ...

  6. Digital approach to high rate gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Korolczuk, Stefan; Mianowski, Slawomir; Rzadkiewicz, Jacek; Sibczynski, Pawel; Swiderski, Lukasz; Szewinski, Jaroslaw; Zychor, Izabella [Narodowe Centrum Badan Jadrowych (NCBJ), 05-400 Otwock, (Poland)

    2015-07-01

    Basic concepts and preliminary results of creating high rate digital spectrometry system using efficient ADCs and latest FPGA are presented as well as a comparison with commercially available devices. The possibility to use such systems, coupled to scintillators, in plasma experiments is discussed. (authors)

  7. Pedalling rate affects endurance performance during high-intensity cycling

    DEFF Research Database (Denmark)

    Nielsen, Jens Steen; Hansen, Ernst Albin; Sjøgaard, Gisela

    2004-01-01

    The purpose of this study into high-intensity cycling was to: (1) test the hypothesis that endurance time is longest at a freely chosen pedalling rate (FCPR), compared to pedalling rates 25% lower (FCPR-25) and higher (FCPR+25) than FCPR, and (2) investigate how physiological variables......, and endurance time at W90 with FCPR-25, FCPR, and FCPR+25. Power reserve was calculated as the difference between applied power output at a given pedalling rate and peak crank power at this same pedalling rate. W90 was 325 (47) W. FCPR at W90 was 78 (11) rpm, resulting in FCPR-25 being 59 (8) rpm and FCPR+25...... time was negatively related to VO(2max), W90 and % MHC I, while positively related to power reserve. In conclusion, at group level, endurance time was longer at FCPR and at a pedalling rate 25% lower compared to a pedalling rate 25% higher than FCPR. Further, inter-individual physiological variables...

  8. Transperineal high-dose-rate interstitial radiation therapy in the management of gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Itami, Jun; Hara, Ryuseke; Kozuka, Takuyou; Yamashita, Hideomi; Nakajima, Kaori; Shibata, Kouji; Abe, Yoshihisa; Fuse, Masashi; Ito, Masashi [International Medical Center of Japan, Tokyo (Japan). Dept. of Radiation Therapy and Oncology

    2003-11-01

    Background: High-dose-rate interstitial radiation therapy is a newly introduced modality, and its role in the management of gynecologic malignancies remains to be studied. Clinical experience in high-dose-rate interstitial radiation therapy was retrospectively investigated. Patients and Methods: Eight patients with primary and nine with recurrent gynecologic malignancies underwent high-dose-rate interstitial radiation therapy with/without external-beam irradiation. Fractional dose of the high-dose-rate interstitial radiation therapy ranged between 4 and 6 Gy with total doses of 15-54 Gy. Interstitial irradiation was performed twice daily with an interval of > 6 h. Results: 2-year local control rate was 75% for primary treatment and 47% for treatment of recurrence (p = 0.46). Maximum tumor size had a statistically significant impact on local control (p < 0.002). Grade 2 and 4 late complications were seen in five patients, and the incidence was significantly higher in patients with a larger volume enclosed by the prescribed fractional dose of high-dose-rate interstitial radiation therapy. The incidence of grade 2 and 4 complications at 18 months was 78% and 0% with a volume > 100 cm{sup 3} and {<=} 100 cm{sup 3}, respectively (p < 0.04). Conclusion: Although high-dose-rate interstitial radiation therapy is a promising modality, it must be applied cautiously to patients with bulky tumors because of the high incidence of serious complications. (orig.)

  9. High-rate synthesis of microcrystalline silicon films using high-density SiH4/H2 microwave plasma

    International Nuclear Information System (INIS)

    Jia, Haijun; Saha, Jhantu K.; Ohse, Naoyuki; Shirai, Hajime

    2007-01-01

    A high electron density (> 10 11 cm -3 ) and low electron temperature (1-2 eV) plasma is produced by using a microwave plasma source utilizing a spoke antenna, and is applied for the high-rate synthesis of high quality microcrystalline silicon (μc-Si) films. A very fast deposition rate of ∼ 65 A/s is achieved at a substrate temperature of 150 deg. C with a high Raman crystallinity and a low defect density of (1-2) x 10 16 cm -3 . Optical emission spectroscopy measurements reveal that emission intensity of SiH and intensity ratio of H α /SiH are good monitors for film deposition rate and film crystallinity, respectively. A high flux of film deposition precursor and atomic hydrogen under a moderate substrate temperature condition is effective for the fast deposition of highly crystallized μc-Si films without creating additional defects as well as for the improvement of film homogeneity

  10. The impact of increased airflow rates on indoor temperatures of passive house in The Netherlands

    NARCIS (Netherlands)

    Barbosa, R.; Loomans, M.G.L.C.; Hensen, J.L.M.; Bartak, M.; Loomans, M.G.L.C.; Kulve, te M.

    2015-01-01

    The increasing number of highly insulated and air tight buildings leads to the concern of indoor environment overheating and related comfort and health issues. This can already happen in a temperate climate as found in the Netherlands. This work studies the ventilative cooling process as a

  11. High Data Rate Optical Wireless Communications Based on Ultraviolet Band

    KAUST Repository

    Sun, Xiaobin

    2017-10-01

    Optical wireless communication systems based on ultraviolet (UV)-band has a lot inherent advantages, such as low background solar radiation, low device dark noise. Besides, it also has small restrictive requirements for PAT (pointing, acquisition, and tracking) because of its high atmospheric scattering with molecules and aerosols. And these advantages are driving people to explore and utilize UV band for constructing and implementing a high-data-rate, less PAT communication links, such as diffuse-line-of-sight links (diffuse-LOS) and non-line-of-sight (NLOS). The responsivity of the photodetector at UV range is far lower than that of visible range, high power UV transmitters which can be easily modulated are under investigation. These factors make it is hard to realize a high-data-rate diffuse-LOS or NLOS UV communication links. To achieve a UV link mentioned above with current devices and modulation schemes, this thesis presents some efficient modulation schemes and available devices for the time being. Besides, a demonstration of ultraviolet-B (UVB) communication link is implemented utilizing quadrature amplitude modulation (QAM) orthogonal frequency-division multiplexing (OFDM). The demonstration is based on a 294-nm UVB-light-emitting-diode (UVB-LED) with a full-width at half-maximum (FWHM) of 9 nm, and according to the measured L-I-V curve, we set the bias voltage as 7V for maximum the ac amplitude and thus get a high signal-noise-ratio (SNR) channel, and the light output power is 190 μW with such bias voltage. Besides, there is a unique silica gel lens on top of the LED to concentrate the beam. A -3-dB bandwidth of 29 MHz was measured and a high-speed near-solar-blind communication link with a data rate of 71 Mbit/s was achieved using 8-QAM-OFDM at perfect alignment, and 23.6 Mbit/s using 2-QAM-OFDM when the angle subtended by the pointing direction of the UVB-LED and photodetector (PD) is 12 degrees, thus establishing a diffuse-line-of-sight (LOS) link

  12. Highly variable rates of genome rearrangements between hemiascomycetous yeast lineages.

    Directory of Open Access Journals (Sweden)

    2006-03-01

    Full Text Available Hemiascomycete yeasts cover an evolutionary span comparable to that of the entire phylum of chordates. Since this group currently contains the largest number of complete genome sequences it presents unique opportunities to understand the evolution of genome organization in eukaryotes. We inferred rates of genome instability on all branches of a phylogenetic tree for 11 species and calculated species-specific rates of genome rearrangements. We characterized all inversion events that occurred within synteny blocks between six representatives of the different lineages. We show that the rates of macro- and microrearrangements of gene order are correlated within individual lineages but are highly variable across different lineages. The most unstable genomes correspond to the pathogenic yeasts Candida albicans and Candida glabrata. Chromosomal maps have been intensively shuffled by numerous interchromosomal rearrangements, even between species that have retained a very high physical fraction of their genomes within small synteny blocks. Despite this intensive reshuffling of gene positions, essential genes, which cluster in low recombination regions in the genome of Saccharomyces cerevisiae, tend to remain syntenic during evolution. This work reveals that the high plasticity of eukaryotic genomes results from rearrangement rates that vary between lineages but also at different evolutionary times of a given lineage.

  13. The Effect of Parkinson Disease Tremor Phenotype on Cepstral Peak Prominence and Transglottal Airflow in Vowels and Speech.

    Science.gov (United States)

    Burk, Brittany R; Watts, Christopher R

    2018-02-19

    The physiological manifestations of Parkinson disease are heterogeneous, as evidenced by disease subtypes. Dysphonia has been well documented as an early and progressively significant impairment associated with the disease. The purpose of this study was to investigate how acoustic and aerodynamic measures of vocal function were affected by Parkinson tremor subtype (phenotype) in an effort to better understand the heterogeneity of voice impairment severity in Parkinson disease. This is a prospective case-control study. Thirty-two speakers with Parkinson disease assigned to tremor and nontremor phenotypes and 10 healthy controls were recruited. Sustained vowels and connected speech were recorded from each speaker. Acoustic measures of cepstral peak prominence (CPP) and aerodynamic measures of transglottal airflow (TAF) were calculated from the recorded acoustic and aerodynamic waveforms. Speakers with a nontremor dominant phenotype exhibited significantly (P Parkinson tremor phenotype in mild to moderate stages of the disease. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  14. The High Strain Rate Deformation Behavior of High Purity Magnesium and AZ31B Magnesium Alloy

    Science.gov (United States)

    Livescu, Veronica; Cady, Carl M.; Cerreta, Ellen K.; Henrie, Benjamin L.; Gray, George T.

    The deformation in compression of pure magnesium and AZ31B magnesium alloy, both with a strong basal pole texture, has been investigated as a function of temperature, strain rate, and specimen orientation. The mechanical response of both metals is highly dependent upon the orientation of loading direction with respect to the basal pole. Specimens compressed along the basal pole direction have a high sensitivity to strain rate and temperature and display a concave down work hardening behavior. Specimens loaded perpendicularly to the basal pole have a yield stress that is relatively insensitive to strain rate and temperature and a work hardening behavior that is parabolic and then linearly upwards. Both specimen orientations display a mechanical response that is sensitive to temperature and strain rate. Post mortem characterization of the pure magnesium was conducted on a subset of specimens to determine the microstructural and textural evolution during deformation and these results are correlated with the observed work hardening behavior and strain rate sensitivities were calculated.

  15. High-energy, high-repetition-rate picosecond pulses from a quasi-CW diode-pumped Nd:YAG system.

    Science.gov (United States)

    Noom, Daniel W E; Witte, Stefan; Morgenweg, Jonas; Altmann, Robert K; Eikema, Kjeld S E

    2013-08-15

    We report on a high-power quasi-CW pumped Nd:YAG laser system, producing 130 mJ, 64 ps pulses at 1064 nm wavelength with a repetition rate of 300 Hz. Pulses from a Nd:YVO(4) oscillator are first amplified by a regenerative amplifier to the millijoule level and then further amplified in quasi-CW diode-pumped Nd:YAG modules. Pulsed diode pumping enables a high gain at repetition rates of several hundred hertz, while keeping thermal effects manageable. Birefringence compensation and multiple thermal-lensing-compensated relay-imaging stages are used to maintain a top-hat beam profile. After frequency doubling, 75 mJ pulses are obtained at 532 nm. The intensity stability is better than 1.1%, which makes this laser an attractive pump source for a high-repetition-rate optical parametric amplification system.

  16. A Model for High-Strain-Rate Deformation of Uranium-Niobium Alloys

    Energy Technology Data Exchange (ETDEWEB)

    F.L.Addessio; Q.H.Zuo; T.A.Mason; L.C.Brinson

    2003-05-01

    A thermodynamic approach is used to develop a framework for modeling uranium-niobium alloys under the conditions of high strain rate. Using this framework, a three-dimensional phenomenological model, which includes nonlinear elasticity (equation of state), phase transformation, crystal reorientation, rate-dependent plasticity, and porosity growth is presented. An implicit numerical technique is used to solve the evolution equations for the material state. Comparisons are made between the model and data for low-strain-rate loading and unloading as well as for heating and cooling experiments. Comparisons of the model and data also are made for low- and high-strain-rate uniaxial stress and uniaxial strain experiments. A uranium-6 weight percent niobium alloy is used in the comparisons of model and experiment.

  17. A pulse shape discriminator with high precision of neutron and gamma ray selection at high counting rate

    International Nuclear Information System (INIS)

    Bialkowski, J.; Moszynski, M.; Wolski, D.

    1989-01-01

    A pulse shape discriminator based on the zero-crossing principle is described. Due to dc negative feedback loops stabilizing the shaping amplifier and the zero-crossing discriminator, the working of the circuit is not affected by the high counting rate and the temperature variations. The pileup rejection circuit built into the discriminator improves the quality of the n-γ separation at high counting rates. A full γ-ray rejection is obtained for a recoil energy of electrons down to 25 keV. At high counting rates the remaining γ-ray contribution is evidently due to the pileup effect which is equal to about 2% at 4x10 5 counts/s. (orig.)

  18. Development of a cryogenic hydrogen microjet for high-intensity, high-repetition rate experiments

    Science.gov (United States)

    Kim, J. B.; Göde, S.; Glenzer, S. H.

    2016-11-01

    The advent of high-intensity, high-repetition-rate lasers has led to the need for replenishing targets of interest for high energy density sciences. We describe the design and characterization of a cryogenic microjet source, which can deliver a continuous stream of liquid hydrogen with a diameter of a few microns. The jet has been imaged at 1 μm resolution by shadowgraphy with a short pulse laser. The pointing stability has been measured at well below a mrad, for a stable free-standing filament of solid-density hydrogen.

  19. Obstetrician perceptions of the causes of high cesarean delivery rates in Turkey.

    Science.gov (United States)

    Küçük, Mert

    2017-07-01

    To assess obstetricians' perceptions surrounding cesarean delivery rates in Turkey. The present cross-sectional descriptive study was performed between May 1 and June 30, 2016. Practicing obstetricians with contact details known by the researchers and those attending a conference in Turkey were asked to complete a self-administered questionnaire that collected demographic data and information on participants' opinions, beliefs, knowledge, attitudes, and practices related to cesarean delivery. There were 100 obstetricians who responded to the survey. Awareness of high cesarean delivery rates was reported by 96 (96%) participants and 95 (95%) respondents said they were supportive of efforts to reduce it. There were 60 (60%), 83 (83%), and 100 (100%) participants aware of associations between high cesarean delivery rates and increased maternal and infant mortality; increased risk of uterine rupture; and increased risk of placenta previa, placenta accreta, and emergency cesarean hysterectomy, respectively. The most commonly reported reason for high cesarean delivery rates was high compensation costs during medical litigation legal proceedings, reported by all 100 (100%) participants. Participants were generally aware of the risks associated with high cesarean delivery rates. The results suggest that the greatest concern among obstetricians who perform cesarean deliveries was malpractice litigation. © 2017 International Federation of Gynecology and Obstetrics.

  20. THE AMERICAN HIGH SCHOOL GRADUATION RATE: TRENDS AND LEVELS*

    Science.gov (United States)

    Heckman, James J.; LaFontaine, Paul A.

    2009-01-01

    This paper applies a unified methodology to multiple data sets to estimate both the levels and trends in U.S. high school graduation rates. We establish that (a) the true rate is substantially lower than widely used measures; (b) it peaked in the early 1970s; (c) majority/minority differentials are substantial and have not converged for 35 years; (d) lower post-1970 rates are not solely due to increasing immigrant and minority populations; (e) our findings explain part of the slowdown in college attendance and rising college wage premiums; and (f) widening graduation differentials by gender help explain increasing male-female college attendance gaps. PMID:20625528

  1. THE AMERICAN HIGH SCHOOL GRADUATION RATE: TRENDS AND LEVELS.

    Science.gov (United States)

    Heckman, James J; Lafontaine, Paul A

    2010-05-01

    This paper applies a unified methodology to multiple data sets to estimate both the levels and trends in U.S. high school graduation rates. We establish that (a) the true rate is substantially lower than widely used measures; (b) it peaked in the early 1970s; (c) majority/minority differentials are substantial and have not converged for 35 years; (d) lower post-1970 rates are not solely due to increasing immigrant and minority populations; (e) our findings explain part of the slowdown in college attendance and rising college wage premiums; and (f) widening graduation differentials by gender help explain increasing male-female college attendance gaps.

  2. Precision tracking at high background rates with the ATLAS muon spectrometer

    CERN Document Server

    Hertenberger, Ralf; The ATLAS collaboration

    2012-01-01

    Since start of data taking the ATLAS muon spectrometer performs according to specification. End of this decade after the luminosity upgrade of LHC by a factor of ten the proportionally increasing background rates require the replacement of the detectors in the most forward part of the muon spectrometer to ensure high quality muon triggering and tracking at background hit rates of up to 15,kHz/cm$^2$. Square meter sized micromegas detectors together with improved thin gap trigger detectors are suggested as replacement. Micromegas detectors are intrinsically high rate capable. A single hit spatial resolution below 40,$mu$m has been shown for 250,$mu$m anode strip pitch and perpendicular incidence of high energy muons or pions. The ongoing development of large micromegas structures and their investigation under non-perpendicular incidence or in high background environments requires precise and reliable monitoring of muon tracks. A muon telescope consisting of six small micromegas works reliably and is presently ...

  3. Post Occupancy Evaluation of 23 Newly Renovated Apartments in Copenhagen

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Afshari, Alireza; Bergsøe, Niels Christian

    2016-01-01

    systems. All the ventilation units are equipped with parallel plate cross flow heat exchangers. The analysis in present article is based on the measured indoor quality parameters as well as energy consumptions. Among four different types of ventilation systems, Type 1 is a traditional decentralized...... ventilation system which works only on two speeds i.e. high airflow rates when kitchen exhaust is on otherwise nominal airflow rates. Type 2 ventilation systems are the decentralized ventilation system with motion sensors in hallways, humidity sensors in rooms and kitchen exhaust hood sensors. Type 3...... ventilation system is a centralized ventilation system with the motion sensors in hallways and toilets, humidity sensors in each room, and kitchen exhaust hood sensors. Type 4 ventilation system is a centralized ventilation system with only kitchen exhaust hood sensor. Type 2, Type 3 and Type 4 ventilation...

  4. State-level high school completion rates: Concepts, measures, and trends.

    Directory of Open Access Journals (Sweden)

    John Robert Warren

    2005-12-01

    Full Text Available Since the mid 1970s the national rate at which incoming 9th graders have completed high school has fallen slowly but steadily; this is also true in 41 states. In 2002, about three in every four students who might have completed high school actually did so; in some states this figure is substantially lower. In this paper I review state-level measures of high school completion rates and describe and validate a new measure that reports these rates for 1975 through 2002. Existing measures based on the Current Population Survey are conceptually imperfect and statistically unreliable. Measures based on Common Core Data (CCD dropout information are unavailable for many states and have different conceptual weaknesses. Existing measures based on CCD enrollment and completion data are systematically biased by migration, changes in cohort size, and/or grade retention. The new CCD-based measure described here is considerably less biased, performs differently in empirical analyses, and gives a different picture of the dropout situation across states and over time.

  5. Miniaturized Stretchable and High-Rate Linear Supercapacitors

    OpenAIRE

    Zhu, Wenjun; Zhang, Yang; Zhou, Xiaoshuang; Xu, Jiang; Liu, Zunfeng; Yuan, Ningyi; Ding, Jianning

    2017-01-01

    Linear stretchable supercapacitors have attracted much attention because they are well suited to applications in the rapidly expanding field of wearable electronics. However, poor conductivity of the electrode material, which limits the transfer of electrons in the axial direction of the linear supercapacitors, leads to a serious loss of capacity at high rates. To solve this problem, we use gold nanoparticles to decorate aligned multiwall carbon nanotube to fabricate stretchable linear electr...

  6. READOUT ELECTRONICS FOR A HIGH-RATE CSC DETECTOR

    International Nuclear Information System (INIS)

    OCONNOR, P.; GRATCHEV, V.; KANDASAMY, A.; POLYCHRONAKOS, V.; TCHERNIATINE, V.; PARSONS, J.; SIPPACH, W.

    1999-01-01

    A readout system for a high-rate muon Cathode Strip Chamber (CSC) is described. The system, planned for use in the forward region of the ATLAS muon spectrometer, uses two custom CMOS integrated circuits to achieve good position resolution at a flux of up to 2,500 tracks/cm 2 /s

  7. Mathematical modeling of high-rate Anammox UASB reactor based on granular packing patterns

    International Nuclear Information System (INIS)

    Tang, Chong-Jian; He, Rui; Zheng, Ping; Chai, Li-Yuan; Min, Xiao-Bo

    2013-01-01

    Highlights: ► A novel model was conducted to estimate volumetric nitrogen conversion rates. ► The packing patterns of the granules in Anammox reactor are investigated. ► The simple cubic packing pattern was simulated in high-rate Anammox UASB reactor. ► Operational strategies concerning sludge concentration were proposed by the modeling. -- Abstract: A novel mathematical model was developed to estimate the volumetric nitrogen conversion rates of a high-rate Anammox UASB reactor based on the packing patterns of granular sludge. A series of relationships among granular packing density, sludge concentration, hydraulic retention time and volumetric conversion rate were constructed to correlate Anammox reactor performance with granular packing patterns. It was suggested that the Anammox granules packed as the equivalent simple cubic pattern in high-rate UASB reactor with packing density of 50–55%, which not only accommodated a high concentration of sludge inside the reactor, but also provided large pore volume, thus prolonging the actual substrate conversion time. Results also indicated that it was necessary to improve Anammox reactor performance by enhancing substrate loading when sludge concentration was higher than 37.8 gVSS/L. The established model was carefully calibrated and verified, and it well simulated the performance of granule-based high-rate Anammox UASB reactor

  8. Mathematical modeling of high-rate Anammox UASB reactor based on granular packing patterns

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chong-Jian, E-mail: chjtangzju@yahoo.com.cn [Department of Environmental Engineering, School of Metallurgical Science and Engineering, Central South University, Changsha 410083 (China); National Engineering Research Center for Control and Treatment of Heavy Metal Pollution, Changsha 410083 (China); He, Rui; Zheng, Ping [Department of Environmental Engineering, Zhejiang University, Zijingang Campus, Hangzhou 310058 (China); Chai, Li-Yuan; Min, Xiao-Bo [Department of Environmental Engineering, School of Metallurgical Science and Engineering, Central South University, Changsha 410083 (China); National Engineering Research Center for Control and Treatment of Heavy Metal Pollution, Changsha 410083 (China)

    2013-04-15

    Highlights: ► A novel model was conducted to estimate volumetric nitrogen conversion rates. ► The packing patterns of the granules in Anammox reactor are investigated. ► The simple cubic packing pattern was simulated in high-rate Anammox UASB reactor. ► Operational strategies concerning sludge concentration were proposed by the modeling. -- Abstract: A novel mathematical model was developed to estimate the volumetric nitrogen conversion rates of a high-rate Anammox UASB reactor based on the packing patterns of granular sludge. A series of relationships among granular packing density, sludge concentration, hydraulic retention time and volumetric conversion rate were constructed to correlate Anammox reactor performance with granular packing patterns. It was suggested that the Anammox granules packed as the equivalent simple cubic pattern in high-rate UASB reactor with packing density of 50–55%, which not only accommodated a high concentration of sludge inside the reactor, but also provided large pore volume, thus prolonging the actual substrate conversion time. Results also indicated that it was necessary to improve Anammox reactor performance by enhancing substrate loading when sludge concentration was higher than 37.8 gVSS/L. The established model was carefully calibrated and verified, and it well simulated the performance of granule-based high-rate Anammox UASB reactor.

  9. A novel hardware implementation for detecting respiration rate using photoplethysmography.

    Science.gov (United States)

    Prinable, Joseph; Jones, Peter; Thamrin, Cindy; McEwan, Alistair

    2017-07-01

    Asthma is a serious public health problem. Continuous monitoring of breathing may offer an alternative way to assess disease status. In this paper we present a novel hardware implementation for the capture and storage of a photoplethysmography (PPG) signal. The LED duty cycle was altered to determine the effect on respiratory rate accuracy. The oximeter was mounted to the left index finger of ten healthy volunteers. The breathing rate derived from the oximeter was validated against a nasal airflow sensor. The duty cycle of a pulse oximeter was changed between 5%, 10% and 25% at a sample rate of 500 Hz. A PPG signal and reference signal was captured for each duty cycle. The PPG signals were post processed in Matlab to derive a respiration rate using an existing Matlab toolbox. At a 25% duty cycle the RMSE was <;2 breaths per minute for the top performing algorithm. The RMSE increased to over 5 breaths per minute when the duty cycle was reduced to 5%. The power consumed by the hardware for a 5%, 10% and 25% duty cycle was 5.4 mW, 7.8 mW, and 15 mW respectively. For clinical assessment of respiratory rate, a RSME of <;2 breaths per minute is recommended. Further work is required to determine utility in asthma management. However for non-clinical applications such as fitness tracking, lower accuracy may be sufficient to allow a reduced duty cycle setting.

  10. Abuse resistant high rate lithium/thionyl chloride cells

    Science.gov (United States)

    Surprenant, J.; Snuggerud, D.

    A compact, disk shaped lithium/thionyl chloride cell has been developed. The cell has a 6 Amphr capacity and is capable of high rate discharge at high voltage. Discharge data are presented over the range of 0.07 to 1.1 amperes. The cell is operable over the temperature range of -40 C to +70 C, and has a 10 year shelf life at 20 C. Safety features allow the cells to withstand fire, puncture, shock, spin, forced discharge or forced charge without dangerous reactions.

  11. High-Pressure Limit Rate Rules for α-H Isomerization of Hydroperoxyalkylperoxy Radicals

    KAUST Repository

    Mohamed, Samah Y; Davis, Alexander Cory; Al Rashidi, Mariam J; Sarathy, Mani

    2018-01-01

    group. In this work, a combination of high level composite methods - CBS-QB3, G3 and G4 - is used to determine the high-pressure-limit rate parameters for the title reaction. Rate rules for H-migration reactions proceeding through 5-, 6-, 7- and 8

  12. Effect of accessory ostia on maxillary sinus ventilation: a computational fluid dynamics (CFD) study.

    Science.gov (United States)

    Zhu, Jian Hua; Lee, Heow Pueh; Lim, Kian Meng; Gordon, Bruce R; Wang, De Yun

    2012-08-15

    We evaluated, by CFD simulation, effects of accessory ostium (AO) on maxillary sinus ventilation. A three-dimensional nasal model was constructed from an adult CT scan with two left maxillary AOs (sinus I) and one right AO (sinus II), then compared to an identical control model with all AOs sealed (sinuses III and IV). Transient simulations of quiet inspiration and expiration at 15 L/min, and nasal blow at 48 L/min, were calculated for both models using low-Reynolds-number turbulent analysis. At low flows, ventilation rates in sinuses with AOs (I ≈ 0.46 L/min, II ≈ 0.54 L/min), were both more than a magnitude higher than sinuses without AOs (II I ≈ 0.019 L/min, IV ≈ 0.020 L/min). Absence of AO almost completely prevented sinus ventilation. Increased ventilation of sinuses with AOs is complex. Under high flow conditions mimicking nose blowing, in sinuses II, III, and IV, the sinus flow rate increased. In contrast, the airflow direction through sinus I reversed between inspiration and expiration, while it remained almost constant throughout the respiration cycle in sinus II. CFD simulation demonstrated that AOs markedly increase maxillary sinus airflow rates and alter sinus air circulation patterns. Whether these airflow changes impact maxillary sinus physiology or pathophysiology is unknown. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. High speed surface cleaning by a high repetition rated TEA-CO2 laser

    International Nuclear Information System (INIS)

    Tsunemi, Akira; Hirai, Ryo; Hagiwara, Kouji; Nagasaka, Keigo; Tashiro, Hideo

    1994-01-01

    We demonstrated the feasibility of high speed cleaning of solid surfaces by the laser ablation technique using a TEA-CO 2 laser. The laser pulses with the repetition rate of 1 kHz were applied to paint, rust, moss and dirt attached on the surfaces. The attachments were effectively removed without the damage of bulk surfaces by the irradiation of line-focused sequential pulses with an energy of 300 mJ/pulse. A cleaning rate reached to 17 m 2 /hour for the case of paint removal from iron surfaces. (author)

  14. Measurement of viscosity of slush at high shear rates

    OpenAIRE

    小林, 俊一; 川村, 公之; 津川, 圭一; 和泉, 薫; Kobayashi, Shun'ichi; Kawamura, Kimiyuki; Tugawa, Keiichi; Izumi, Kaoru

    1988-01-01

    Measurements of viscosity of slush were carried out using a method of flow along an inclined smooth surface in a 0℃cold room. The method was used to get the values of viscosity under high shear rates (25 and 75s^). From our experiments two important results were obtained: 1) the viscosity of slush decreases with increasing shear rates; 2) The fluid behavior is pseudoplastic that the values of non-Newtonian index of viscosity were less than unity.

  15. Design and Development of High-Repetition-Rate Satellite Laser Ranging System

    Science.gov (United States)

    Choi, Eun-Jung; Bang, Seong-Cheol; Sung, Ki-Pyoung; Lim, Hyung-Chul; Jung, Chan-Gyu; Kim, In-Yeung; Choi, Jae-Seung

    2015-09-01

    The Accurate Ranging System for Geodetic Observation ? Mobile (ARGO-M) was successfully developed as the first Korean mobile Satellite Laser Ranging (SLR) system in 2012, and has joined in the International Laser Ranging Service (ILRS) tracking network, DAEdeoK (DAEK) station. The DAEK SLR station was approved as a validated station in April 2014, through the ILRS station ¡°data validation¡± process. The ARGO-M system is designed to enable 2 kHz laser ranging with millimeter-level precision for geodetic, remote sensing, navigation, and experimental satellites equipped with Laser Retroreflector Arrays (LRAs). In this paper, we present the design and development of a next generation high-repetition-rate SLR system for ARGO-M. The laser ranging rate up to 10 kHz is becoming an important issue in the SLR community to improve ranging precision. To implement high-repetition-rate SLR system, the High-repetition-rate SLR operation system (HSLR-10) was designed and developed using ARGO-M Range Gate Generator (A-RGG), so as to enable laser ranging from 50 Hz to 10 kHz. HSLR-10 includes both hardware controlling software and data post-processing software. This paper shows the design and development of key technologies of high-repetition-rate SLR system. The developed system was tested successfully at DAEK station and then moved to Sejong station, a new Korean SLR station, on July 1, 2015. HSLR-10 will begin normal operations at Sejong station in the near future.

  16. Regulation and drive system for high rep-rate magnetic-pulse compressors

    International Nuclear Information System (INIS)

    Birx, D.L.; Cook, E.G.; Hawkins, S.; Meyers, A.; Reginato, L.L.; Schmidt, J.A.; Smith, M.W.

    1982-01-01

    The essentially unlimited rep-rate capability of non-linear magnetic systems has imposed strict requirements on the drive system which initiates the pulse compression. An order of magnitude increase in the rep-rates achieved by the Advanced Test Accelerator (ATA) gas blown system is not difficult to achieve in the magnetic compressor. The added requirement of having a high degree of regulation at the higher rep-rates places strict requirements on the triggerable switch for charging and de-Queing. A novel feedback technique which applies the proper bias to a magnetic core by comparing a reference voltage to the charging voltage eases considerably the regulation required to achieve low jitter in magnetic compression. The performance of the high rep-rate charging and regulation systems will be described in the following pages

  17. Sterilization efficacy of ultraviolet irradiation on microbial aerosols under dynamic airflow by experimental air conditioning systems

    International Nuclear Information System (INIS)

    Nakamura, Hiroshi

    1987-01-01

    In order to know the sterilization efficacy of ultraviolet irradiation on microbial aerosols, the size and the weight of the aerosol particles were evaluated, and these were irradiated under dynamic air flow created by an experimental air conditioning system. The experimental apparatus consisted of a high efficiency particulate air (HEPA) filter, an aerosol generator, spiral UV lamps placed around a quart glass tube, an Andersen air sampler and a vacuum pump. They were connected serially by stainless steel ducts (85 mm in diameter, 8 m in length). Six types of microbial aerosols generated from an ultrasonic nebulizer were irradiated by UV rays (wavelength 254 nm, mean density 9400 μW/cm 2 ). Their irradiation time ranged from 1.0 to 0.0625 seconds. The microbial aerosols were collected onto the trypticase soy agar (TSA) medium in the Andersen air sampler. After incubation, the number of colony forming units (CFU) were counted, and converted to particle counts. The diameter of microbial aerosol particles calculated by their log normal distribution were found to match the diameter of a single bacteria cell measured by a microscope. The sterilization efficacy of UV in standard airflow conditions (0.5 sec. irradiation) were found to be over 99.5 % in Staphylococcus aureus, Staphylococcus epidermidis, Serratia marcescens, Bacillus subtilis (vegetative cell) and Bacillus subtilis (spore) and 67 % in Aspergillus niger (conidium). In A. niger, which was the most resistant microbe to UV irradiation, the efficacy rose up to 79 % when irradiated for 1.0 sec., and it was observed that the growth speed of the colonies was slower than that of the controls. It was thought that UV rays caused some damage to the proliferation of A. niger cells. (author)

  18. High-rate capability of lithium-ion batteries after storing at elevated temperature

    International Nuclear Information System (INIS)

    Wu, Mao-Sung; Chiang, Pin-Chi Julia

    2007-01-01

    High-rate performances of a lithium-ion battery after storage at elevated temperature are investigated electrochemically by means of three-electrode system. The high-rate capability is decreased significantly after high-temperature storage. A 3 C discharge capacities after room-temperature storage and 60 o C storage are 650 and 20 mAh, respectively. Lithium-ion diffusion in lithium cobalt oxide cathode limits the battery's capacity and the results show that storage temperature changes this diffusion behavior. Transmission electron microscopy (TEM) images show that many defects are directly observed in the cathode after storage compared with the fresh cathode; the structural defects block the diffusion within the particles. Electrochemical impedance and polarization curve indicate that mass-transfer (diffusion) dominates the discharge capacity during high-rate discharge

  19. High strain rate deformation of layered nanocomposites

    Science.gov (United States)

    Lee, Jae-Hwang; Veysset, David; Singer, Jonathan P.; Retsch, Markus; Saini, Gagan; Pezeril, Thomas; Nelson, Keith A.; Thomas, Edwin L.

    2012-11-01

    Insight into the mechanical behaviour of nanomaterials under the extreme condition of very high deformation rates and to very large strains is needed to provide improved understanding for the development of new protective materials. Applications include protection against bullets for body armour, micrometeorites for satellites, and high-speed particle impact for jet engine turbine blades. Here we use a microscopic ballistic test to report the responses of periodic glassy-rubbery layered block-copolymer nanostructures to impact from hypervelocity micron-sized silica spheres. Entire deformation fields are experimentally visualized at an exceptionally high resolution (below 10 nm) and we discover how the microstructure dissipates the impact energy via layer kinking, layer compression, extreme chain conformational flattening, domain fragmentation and segmental mixing to form a liquid phase. Orientation-dependent experiments show that the dissipation can be enhanced by 30% by proper orientation of the layers.

  20. High strain rate deformation of layered nanocomposites.

    Science.gov (United States)

    Lee, Jae-Hwang; Veysset, David; Singer, Jonathan P; Retsch, Markus; Saini, Gagan; Pezeril, Thomas; Nelson, Keith A; Thomas, Edwin L

    2012-01-01

    Insight into the mechanical behaviour of nanomaterials under the extreme condition of very high deformation rates and to very large strains is needed to provide improved understanding for the development of new protective materials. Applications include protection against bullets for body armour, micrometeorites for satellites, and high-speed particle impact for jet engine turbine blades. Here we use a microscopic ballistic test to report the responses of periodic glassy-rubbery layered block-copolymer nanostructures to impact from hypervelocity micron-sized silica spheres. Entire deformation fields are experimentally visualized at an exceptionally high resolution (below 10 nm) and we discover how the microstructure dissipates the impact energy via layer kinking, layer compression, extreme chain conformational flattening, domain fragmentation and segmental mixing to form a liquid phase. Orientation-dependent experiments show that the dissipation can be enhanced by 30% by proper orientation of the layers.