WorldWideScience

Sample records for hemoglobin electronic resource

  1. Facile Interfacial Electron Transfer of Hemoglobin

    Chunhai Fan

    2005-12-01

    Full Text Available Abstract: We herein describe a method of depositing hemoglobin (Hb and sulfonated polyaniline (SPAN on GC electrodes that facilitate interfacial protein electron transfer. Well-defined, reproducible, chemically reversible peaks of Hb and SPAN can be obtained in our experiments. We also observed enhanced peroxidase activity of Hb in SPAN films. These results clearly showed that SPAN worked as molecular wires and effectively exchanged electrons between Hb and electrodes.Mediated by Conjugated Polymers

  2. Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting.

    Nkrumah, Bernard; Nguah, Samuel Blay; Sarpong, Nimako; Dekker, Denise; Idriss, Ali; May, Juergen; Adu-Sarkodie, Yaw

    2011-04-21

    In resource poor settings where automated hematology analyzers are not available, the Cyanmethemoglobin method is often used. This method though cheaper, takes more time. In blood donations, the semi-quantitative gravimetric copper sulfate method which is very easy and inexpensive may be used but does not provide an acceptable degree of accuracy. The HemoCue® hemoglobin photometer has been used for these purposes. This study was conducted to generate data to support or refute its use as a point-of-care device for hemoglobin estimation in mobile blood donations and critical care areas in health facilities. EDTA blood was collected from study participants drawn from five groups: pre-school children, school children, pregnant women, non-pregnant women and men. Blood collected was immediately processed to estimate the hemoglobin concentration using three different methods (HemoCue®, Sysmex KX21N and Cyanmethemoglobin). Agreement between the test methods was assessed by the method of Bland and Altman. The Intraclass correlation coefficient (ICC) was used to determine the within subject variability of measured hemoglobin. Of 398 subjects, 42% were males with the overall mean age being 19.4 years. The overall mean hemoglobin as estimated by each method was 10.4 g/dl for HemoCue, 10.3 g/dl for Sysmex KX21N and 10.3 g/dl for Cyanmethemoglobin. Pairwise analysis revealed that the hemoglobin determined by the HemoCue method was higher than that measured by the KX21N and Cyanmethemoglobin. Comparing the hemoglobin determined by the HemoCue to Cyanmethemoglobin, the concordance correlation coefficient was 0.995 (95% CI: 0.994-0.996, p < 0.001). The Bland and Altman's limit of agreement was -0.389 - 0.644 g/dl with the mean difference being 0.127 (95% CI: 0.102-0.153) and a non-significant difference in variability between the two measurements (p = 0.843). After adjusting to assess the effect of other possible confounders such as sex, age and category of person, there was no

  3. Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting

    Idriss Ali

    2011-04-01

    Full Text Available Abstract Background In resource poor settings where automated hematology analyzers are not available, the Cyanmethemoglobin method is often used. This method though cheaper, takes more time. In blood donations, the semi-quantitative gravimetric copper sulfate method which is very easy and inexpensive may be used but does not provide an acceptable degree of accuracy. The HemoCue® hemoglobin photometer has been used for these purposes. This study was conducted to generate data to support or refute its use as a point-of-care device for hemoglobin estimation in mobile blood donations and critical care areas in health facilities. Method EDTA blood was collected from study participants drawn from five groups: pre-school children, school children, pregnant women, non-pregnant women and men. Blood collected was immediately processed to estimate the hemoglobin concentration using three different methods (HemoCue®, Sysmex KX21N and Cyanmethemoglobin. Agreement between the test methods was assessed by the method of Bland and Altman. The Intraclass correlation coefficient (ICC was used to determine the within subject variability of measured hemoglobin. Results Of 398 subjects, 42% were males with the overall mean age being 19.4 years. The overall mean hemoglobin as estimated by each method was 10.4 g/dl for HemoCue, 10.3 g/dl for Sysmex KX21N and 10.3 g/dl for Cyanmethemoglobin. Pairwise analysis revealed that the hemoglobin determined by the HemoCue method was higher than that measured by the KX21N and Cyanmethemoglobin. Comparing the hemoglobin determined by the HemoCue to Cyanmethemoglobin, the concordance correlation coefficient was 0.995 (95% CI: 0.994-0.996, p Conclusion Hemoglobin determined by the HemoCue method is comparable to that determined by the other methods. The HemoCue photometer is therefore recommended for use as on-the-spot device for determining hemoglobin in resource poor setting.

  4. Hemoglobin

    1993-03-08

    affinity, which is less at low levels of hemoglobin saturation, increases markedly as fractional saturation increases. Thus, high affinity for 02 at... diphosphoglycerate (2,3-DPG), and carbon dioxide (Co 2). Since they are linked to 02 binding, they are called oxygen-linked effectors. The oxygen...hemoglobin molecule because of the negative charge of the ions. 2,3- Diphosphoglycerate is a molecule formed during the breakdown of sugar in normal human

  5. Contribution of electron paramagnetic resonance to the studies of hemoglobin: the nitrosylhemoglobin system

    Bemski, G.

    1995-03-01

    Since the initial work of Ingram Electron Paramagnetic Resonance contributed considerably to research in hemoglobins. Now, 40 years later some of the results of the application of EPR to nitrosyl hemoglobin (HbNO), are reviewed as an example of the diversity of information which this technique can provide are reviewed. (author). 34 refs, 7 figs

  6. Electronic Resource Management Systems

    Mark Ellingsen

    2004-10-01

    Full Text Available Computer applications which deal with electronic resource management (ERM are quite a recent development. They have grown out of the need to manage the burgeoning number of electronic resources particularly electronic journals. Typically, in the early years of e-journal acquisition, library staff provided an easy means of accessing these journals by providing an alphabetical list on a web page. Some went as far as categorising the e-journals by subject and then grouping the journals either on a single web page or by using multiple pages. It didn't take long before it was recognised that it would be more efficient to dynamically generate the pages from a database rather than to continually edit the pages manually. Of course, once the descriptive metadata for an electronic journal was held within a database the next logical step was to provide administrative forms whereby that metadata could be manipulated. This in turn led to demands for incorporating more information and more functionality into the developing application.

  7. The Relationship Between Preoperative Hemoglobin Concentration, Use of Hospital Resources, and Outcomes in Cardiac Surgery.

    Hallward, George; Balani, Nikhail; McCorkell, Stuart; Roxburgh, James; Cornelius, Victoria

    2016-08-01

    Preoperative anemia is an established risk factor associated with adverse perioperative outcomes after cardiac surgery. However, limited information exists regarding the relationship between preoperative hemoglobin concentration and outcomes. The aim of this study was to investigate how outcomes are affected by preoperative hemoglobin concentration in a cohort of patients undergoing cardiac surgery. A retrospective, observational cohort study. A single-center tertiary referral hospital. The study comprised 1,972 adult patients undergoing elective and nonelective cardiac surgery. The independent relationship of preoperative hemoglobin concentration was explored on blood transfusion rates, return to the operating room for bleeding and/or cardiac tamponade, postoperative intensive care unit (ICU) and in-hospital length of stay, and mortality. The overall prevalence of anemia was 32% (629/1,972 patients). For every 1-unit increase in hemoglobin (g/dL), blood transfusion requirements were reduced by 11%, 8%, and 3% for red blood cell units, platelet pools, and fresh frozen plasma units, respectively (adjusted incident rate ratio 0.89 [95% CI 0.87-0.91], 0.92 [0.88-0.97], and 0.97 [0.96-0.99]). For each 1-unit increase in hemoglobin (g/dL), the probability (over time) of discharge from the ICU and hospital increased (adjusted hazard ratio estimates 1.04 [1.00-1.08] and 1.12 [1.12-1.16], respectively). A lower preoperative hemoglobin concentration resulted in increased use of hospital resources after cardiac surgery. Each g/dL unit fall in preoperative hemoglobin concentration resulted in increased blood transfusion requirements and increased postoperative ICU and hospital length of stay. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Electronic Resource Management and Design

    Abrams, Kimberly R.

    2015-01-01

    We have now reached a tipping point at which electronic resources comprise more than half of academic library budgets. Because of the increasing work associated with the ever-increasing number of e-resources, there is a trend to distribute work throughout the library even in the presence of an electronic resources department. In 2013, the author…

  9. Analysis of the electronic structure of human hemoglobin from soft X-ray emission

    Soldatov, A.V.; Kravtsova, A.N.; Fedorovich, E.N.; Ankudinov, A.; Moewes, A.; Kurmaev, E.Z.

    2005-01-01

    We present X-ray emission spectra (XES) of human hemoglobin excited near the iron L 2,3 threshold and the nitrogen and carbon K-edges. The experiment is compared with our calculations of the corresponding spectra and gives good agreement. We find that the Fe L 3 emission is affected by the nearest nitrogen atoms located in the heme plane around the central iron atom. The distribution of the partial electronic densities of states of hemoglobin is determined

  10. Electron transfer reactions, cyanide and O2 binding of truncated hemoglobin from Bacillus subtilis

    Fernandez, Esther; Larsson, Jonas T.; McLean, Kirsty J.

    2013-01-01

    The truncated hemoglobin from Bacillus subtilis (trHb-Bs) possesses a surprisingly high affinity for oxygen and resistance to (auto)oxidation; its physiological role in the bacterium is not understood and may be connected with its very special redox and ligand binding reactions. Electron transfer...

  11. Electron self-exchange in hemoglobins revealed by deutero-hemin substitution.

    Athwal, Navjot Singh; Alagurajan, Jagannathan; Sturms, Ryan; Fulton, D Bruce; Andreotti, Amy H; Hargrove, Mark S

    2015-09-01

    Hemoglobins (phytoglobins) from rice plants (nsHb1) and from the cyanobacterium Synechocystis (PCC 6803) (SynHb) can reduce hydroxylamine with two electrons to form ammonium. The reaction requires intermolecular electron transfer between protein molecules, and rapid electron self-exchange might play a role in distinguishing these hemoglobins from others with slower reaction rates, such as myoglobin. A relatively rapid electron self-exchange rate constant has been measured for SynHb by NMR, but the rate constant for myoglobin is equivocal and a value for nsHb1 has not yet been measured. Here we report electron self-exchange rate constants for nsHb1 and Mb as a test of their role in hydroxylamine reduction. These proteins are not suitable for analysis by NMR ZZ exchange, so a method was developed that uses cross-reactions between each hemoglobin and its deutero-hemin substituted counterpart. The resulting electron transfer is between identical proteins with low driving forces and thus closely approximates true electron self-exchange. The reactions can be monitored spectrally due to the distinct spectra of the prosthetic groups, and from this electron self-exchange rate constants of 880 (SynHb), 2900 (nsHb1), and 0.05M(-1) s(-1) (Mb) have been measured for each hemoglobin. Calculations of cross-reactions using these values accurately predict hydroxylamine reduction rates for each protein, suggesting that electron self-exchange plays an important role in the reaction. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Electronic structure of human hemoglobin: ultrasoft X-ray emission study

    Soldatov, A.V.; Kravtsova, A.N.; Fedorovich, E.N.; Kurmaev, E.Z.; Moewes, A.

    2004-01-01

    Full text: The iron L 2,3 and carbon, nitrogen and oxygen Kα X-ray emission spectra (XES) of human hemoglobin have been recorded at the soft X-ray spectroscopy endstation on Undulator Beam line 8.0 at Advanced Light Source (ALS) located at the Lawrence Berkeley National Laboratory. The theoretical calculations of Fe L 3 -XES have been performed using ab initio code FEFF8.2. The calculations have been carried out for the structure of hemoglobin presented in PDB (entry 3HHB) as well as for the molecule with symmetrical heme plane. It was found that the Fe L 3 emission spectrum calculated for the ideal molecule agrees slightly better with the experiment as compared with those calculated for the real molecule. Thus, one can use the structure of the ideal molecule for theoretical Fe L 3 -XES simulations. The theoretical analysis has shown that the fist peak of experimental Fe L 3 - emission spectrum is enhanced by the nearest nitrogen atoms lying in heme plane around the central iron atom. The theoretical C K- and N K-XES spectra of hemoglobin have been calculated. A good agreement between theoretical and experimental spectra has been obtained. The distribution of the partial electronic densities of states in the valence and conduction bands of hemoglobin has been determined

  13. Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin.

    Zhao, Changzhi; Wan, Li; Jiang, Li; Wang, Qin; Jiao, Kui

    2008-12-01

    A cholesterol biosensor based on direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode has been developed for highly sensitive and selective analysis of serum samples. Modified by films containing hemoglobin and cholesterol oxidase, the electrode was prepared by encapsulation of enzyme in chitosan matrix. The hydrogen peroxide produced by the catalytic oxidation of cholesterol by cholesterol oxidase was reduced electrocatalytically by immobilized hemoglobin and used to obtain a sensitive amperometric response to cholesterol. The linear response of cholesterol concentrations ranged from 1.00 x 10(-5) to 6.00 x 10(-4) mol/L, with a correlation coefficient of 0.9969 and estimated detection limit of cholesterol of 9.5 micromol/L at a signal/noise ratio of 3. The cholesterol biosensor can efficiently exclude interference by the commonly coexisting ascorbic acid, uric acid, dopamine, and epinephrine. The sensitivity to the change in the concentration of cholesterol as the slope of the calibration curve was 0.596 A/M. The relative standard deviation was under 4.0% (n=5) for the determination of real samples. The biosensor is satisfactory in the determination of human serum samples.

  14. Managing electronic resources a LITA guide

    Weir, Ryan O

    2012-01-01

    Informative, useful, current, Managing Electronic Resources: A LITA Guide shows how to successfully manage time, resources, and relationships with vendors and staff to ensure personal, professional, and institutional success.

  15. Electronic Resources Management Project Presentation 2012

    Ramli, Rindra M.

    2012-11-05

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration is to consolidate all electronic resources into a single and centralized location. This would allow for better information sharing among library staff.

  16. Implementing CORAL: An Electronic Resource Management System

    Whitfield, Sharon

    2011-01-01

    A 2010 electronic resource management survey conducted by Maria Collins of North Carolina State University and Jill E. Grogg of University of Alabama Libraries found that the top six electronic resources management priorities included workflow management, communications management, license management, statistics management, administrative…

  17. Electronic Resources Management System: Recommendation Report 2017

    Ramli, Rindra M.

    2017-01-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system

  18. Electronic Resources Management Project Presentation 2012

    Ramli, Rindra M.

    2012-01-01

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration

  19. Electron transfer reactions, cyanide and O2 binding of truncated hemoglobin from Bacillus subtilis

    Fernandez, Esther; Larsson, Jonas T.; McLean, Kirsty J.; Munro, Andrew W.; Gorton, Lo; Wachenfeldt, Claes von; Ferapontova, Elena E.

    2013-01-01

    The truncated hemoglobin from Bacillus subtilis (trHb-Bs) possesses a surprisingly high affinity for oxygen and resistance to (auto)oxidation; its physiological role in the bacterium is not understood and may be connected with its very special redox and ligand binding reactions. Electron transfer reactions of trHb-Bs were electrochemically studied in solution and at graphite electrodes. Spectrophotometrical potentiometric titration and direct electrochemical measurements gave a heme iron redox potential of −103 ± 4 mV and −108 ± 2 mV vs. NHE, at pH 7, respectively. The redox potential of the heme in trHb-Bs shifted −59 mV per pH unit at pH higher than 7, consistently with a 1e − /1 H + – transfer reaction. The heterogeneous rate constant k s for a quasi-reversible 1e − – 1H + – transfer reaction between graphite and trHb-Bs was 10.1 ± 2.3 s −1 . Upon reversible cyanide binding the k s doubled, while the redox potential of heme shifted 21 mV negatively, presumably reflecting changes in redox activity and in vivo signaling functions of trHb-Bs associated with ligand binding. Bioelectrocatalytic reduction of O 2 catalyzed by trHb-Bs was one of the most efficient hitherto reported for Hbs, with an apparent catalytic rate constant, k cat , of 56 ± 6 s −1 . The results obtained are of particular interest for applications of trHb in environmental biosensing and toxicity screening

  20. PRINCIPLES OF CONTENT FORMATION EDUCATIONAL ELECTRONIC RESOURCE

    О Ю Заславская

    2017-12-01

    Full Text Available The article considers modern possibilities of information and communication technologies for the design of electronic educational resources. The conceptual basis of the open educational multimedia system is based on the modular architecture of the electronic educational resource. The content of the electronic training module can be implemented in several versions of the modules: obtaining information, practical exercises, control. The regularities in the teaching process in modern pedagogical theory are considered: general and specific, and the principles for the formation of the content of instruction at different levels are defined, based on the formulated regularities. On the basis of the analysis, the principles of the formation of the electronic educational resource are determined, taking into account the general and didactic patterns of teaching.As principles of the formation of educational material for obtaining information for the electronic educational resource, the article considers: the principle of methodological orientation, the principle of general scientific orientation, the principle of systemic nature, the principle of fundamentalization, the principle of accounting intersubject communications, the principle of minimization. The principles of the formation of the electronic training module of practical studies in the article include: the principle of systematic and dose based consistency, the principle of rational use of study time, the principle of accessibility. The principles of the formation of the module for monitoring the electronic educational resource can be: the principle of the operationalization of goals, the principle of unified identification diagnosis.

  1. Electronic Resources Management System: Recommendation Report 2017

    Ramli, Rindra M.

    2017-05-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system as potential replacements namely: Proquest 360 Resource Manager, Ex Libris Alma and Open Source CORAL ERMS. After comparing and trialling the systems, it was decided to go for Proquest 360 Resource Manager.

  2. CHALLENGES OF ELECTRONIC INFORMATION RESOURCES IN ...

    This paper discusses the role of policy for proper and efficient library services in the electronic era. It points out some of the possible dangers of embarking in electronic resources without a proper focus at hand. Thus, it calls for today's librarians and policy makers to brainstorm and come up with working policies suitable to ...

  3. Library training to promote electronic resource usage

    Frandsen, Tove Faber; Tibyampansha, Dativa; Ibrahim, Glory

    2017-01-01

    Purpose: Increasing the usage of electronic resources is an issue of concern for many libraries all over the world. Several studies stress the importance of information literacy and instruction in order to increase the usage. Design/methodology/approach: The present article presents the results...

  4. Hemoglobin (image)

    Hemoglobin is the most important component of red blood cells. It is composed of a protein called ... exchanged for carbon dioxide. Abnormalities of an individual's hemoglobin value can indicate defects in the normal balance ...

  5. Electronic resource management systems a workflow approach

    Anderson, Elsa K

    2014-01-01

    To get to the bottom of a successful approach to Electronic Resource Management (ERM), Anderson interviewed staff at 11 institutions about their ERM implementations. Among her conclusions, presented in this issue of Library Technology Reports, is that grasping the intricacies of your workflow-analyzing each step to reveal the gaps and problems-at the beginning is crucial to selecting and implementing an ERM. Whether the system will be used to fill a gap, aggregate critical data, or replace a tedious manual process, the best solution for your library depends on factors such as your current soft

  6. use of electronic resources by graduate students of the department

    respondent's access electronic resources from the internet via Cybercafé .There is a high ... KEY WORDS: Use, Electronic Resources, Graduate Students, Cybercafé. INTRODUCTION ... Faculty of Education, University of Uyo, Uyo. Olu Olat ...

  7. Direct electron transfer of hemoglobin in a CdS nanorods and Nafion composite film on carbon ionic liquid electrode

    Sun Wei; Wang Dandan; Li Guicun; Zhai Ziqin; Zhao Ruijun; Jiao Kui

    2008-01-01

    In this paper the direct electron transfer of hemoglobin (Hb) was carefully investigated by using a room temperature ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF 6 ) modified carbon paste electrode (CILE) as the basal working electrode. Hb was immobilized on the surface of CILE with the nanocomposite film composed of Nafion and CdS nanorods by a step-by-step method. UV-vis and FT-IR spectra showed that Hb in the composite film remained its native structure. The direct electrochemical behaviors of Hb in the composite film were further studied in a pH 7.0 phosphate buffer solution (PBS). A pair of well-defined and quasi-reversible cyclic voltammetric peaks of Hb was obtained with the formal potential (E 0 ') at -0.295 V (vs. SCE), which was the characteristic of heme Fe(III)/Fe(II) redox couples. The direct electrochemistry of Hb was achieved on the modified electrode and the apparent heterogeneous electron transfer rate constant (k s ) was calculated to be 0.291 s -1 . The formal potentials of Hb Fe(III)/Fe(II) couple shifted negatively with the increase of buffer pH and a slope value of -45.1 mV/pH was got, which indicated that one electron transfer accompanied with one proton transportation. The fabricated Hb sensor showed good electrocatalytic manner to the reduction of trichloroacetic acid (TCA)

  8. Fish hemoglobins

    Souza,P.C. de; Bonilla-Rodriguez,G.O.

    2007-01-01

    Vertebrate hemoglobin, contained in erythrocytes, is a globular protein with a quaternary structure composed of 4 globin chains (2 alpha and 2 beta) and a prosthetic group named heme bound to each one. Having myoglobin as an ancestor, hemoglobin acquired the capacity to respond to chemical stimuli that modulate its function according to tissue requirements for oxygen. Fish are generally submitted to spatial and temporal O2 variations and have developed anatomical, physiological and biochemica...

  9. Use of Electronic Resources in a Private University in Nigeria ...

    The study examined awareness and constraints in the use of electronic resources by lecturers and students of Ajayi Crowther University, Oyo, Nigeria. It aimed at justifying the resources expended in the provision of electronic resources in terms of awareness, patronage and factors that may be affecting awareness and use ...

  10. Gender Analysis Of Electronic Information Resource Use: The Case ...

    Based on the findings the study concluded that access and use of electronic information resources creates a “social digital divide” along gender lines. The study ... Finally, the library needs to change its marketing strategies on the availability of electronic information resources to increase awareness of these resources.

  11. Electronic Resource Management System. Vernetzung von Lizenzinformationen

    Michaela Selbach

    2014-12-01

    Full Text Available In den letzten zehn Jahren spielen elektronische Ressourcen im Bereich der Erwerbung eine zunehmend wichtige Rolle: Eindeutig lässt sich hier ein Wandel in den Bibliotheken (fort vom reinen Printbestand zu immer größeren E-Only-Beständen feststellen. Die stetig wachsende Menge an E-Ressourcen und deren Heterogenität stellt Bibliotheken vor die Herausforderung, die E-Ressourcen effizient zu verwalten. Nicht nur Bibliotheken, sondern auch verhandlungsführende Institutionen von Konsortial- und Allianzlizenzen benötigen ein geeignetes Instrument zur Verwaltung von Lizenzinformationen, welches den komplexen Anforderungen moderner E-Ressourcen gerecht wird. Die Deutsche Forschungsgemeinschaft (DFG unterstützt ein Projekt des Hochschulbibliothekszentrums des Landes Nordrhein-Westfalen (hbz, der Universitätsbibliothek Freiburg, der Verbundzentrale des Gemeinsamen Bibliotheksverbundes (GBV und der Universitätsbibliothek Frankfurt, in dem ein bundesweit verfügbares Electronic Ressource Managementsystem (ERMS aufgebaut werden soll. Ein solches ERMS soll auf Basis einer zentralen Knowledge Base eine einheitliche Nutzung von Daten zur Lizenzverwaltung elektronischer Ressourcen auf lokaler, regionaler und nationaler Ebene ermöglichen. Statistische Auswertungen, Rechteverwaltung für alle angeschlossenen Bibliotheken, kooperative Datenpflege sowie ein über standardisierte Schnittstellen geführter Datenaustausch stehen bei der Erarbeitung der Anforderungen ebenso im Fokus wie die Entwicklung eines Daten- und Funktionsmodells. In the last few years the importance of electronic resources in library acquisitions has increased significantly. There has been a shift from mere print holdings to both e- and print combinations and even e-only subscriptions. This shift poses a double challenge for libraries: On the one hand they have to provide their e-resource collections to library users in an appealing way, on the other hand they have to manage these

  12. Electronic human resource management: Enhancing or entrancing?

    Paul Poisat

    2017-07-01

    Full Text Available Orientation: This article provides an investigation into the current level of development of the body of knowledge related to electronic human resource management (e-HRM by means of a qualitative content analysis. Several aspects of e-HRM, namely definitions of e-HRM, the theoretical perspectives around e-HRM, the role of e-HRM, the various types of e-HRM and the requirements for successful e-HRM, are examined. Research purpose: The purpose of the article was to determine the status of e-HRM and examine the studies that report on the link between e-HRM and organisational productivity. Motivation for the study: e-HRM has the capacity to improve organisational efficiency and leverage the role of human resources (HR as a strategic business partner. Main findings: The notion that the implementation of e-HRM will lead to improved organisational productivity is commonly assumed; however, empirical evidence in this regard was found to be limited. Practical/managerial implications: From the results of this investigation it is evident that more research is required to gain a greater understanding of the influence of e-HRM on organisational productivity, as well as to develop measures for assessing this influence. Contribution: This article proposes additional areas to research and measure when investigating the effectiveness of e-HRM. It provides a different lens from which to view e-HRM assessment whilst keeping it within recognised HR measurement parameters (the HR value chain. In addition, it not only provides areas for measuring e-HRM’s influence but also provides important clues as to how the measurements may be approached.

  13. Utilization of electronic information resources by academic staff at ...

    The study investigated the utilization of Electronic Information resources by the academic staff of Makerere University in Uganda. It examined the academic staff awareness of the resources available, the types of resources provided by the Makerere University Library, the factors affecting resource utilization. The study was ...

  14. Accuracy of hemoglobin A1c imputation using fasting plasma glucose in diabetes research using electronic health records data

    Stanley Xu

    2014-05-01

    Full Text Available In studies that use electronic health record data, imputation of important data elements such as Glycated hemoglobin (A1c has become common. However, few studies have systematically examined the validity of various imputation strategies for missing A1c values. We derived a complete dataset using an incident diabetes population that has no missing values in A1c, fasting and random plasma glucose (FPG and RPG, age, and gender. We then created missing A1c values under two assumptions: missing completely at random (MCAR and missing at random (MAR. We then imputed A1c values, compared the imputed values to the true A1c values, and used these data to assess the impact of A1c on initiation of antihyperglycemic therapy. Under MCAR, imputation of A1c based on FPG 1 estimated a continuous A1c within ± 1.88% of the true A1c 68.3% of the time; 2 estimated a categorical A1c within ± one category from the true A1c about 50% of the time. Including RPG in imputation slightly improved the precision but did not improve the accuracy. Under MAR, including gender and age in addition to FPG improved the accuracy of imputed continuous A1c but not categorical A1c. Moreover, imputation of up to 33% of missing A1c values did not change the accuracy and precision and did not alter the impact of A1c on initiation of antihyperglycemic therapy. When using A1c values as a predictor variable, a simple imputation algorithm based only on age, sex, and fasting plasma glucose gave acceptable results.

  15. Fish hemoglobins

    P.C. de Souza

    2007-06-01

    Full Text Available Vertebrate hemoglobin, contained in erythrocytes, is a globular protein with a quaternary structure composed of 4 globin chains (2 alpha and 2 beta and a prosthetic group named heme bound to each one. Having myoglobin as an ancestor, hemoglobin acquired the capacity to respond to chemical stimuli that modulate its function according to tissue requirements for oxygen. Fish are generally submitted to spatial and temporal O2 variations and have developed anatomical, physiological and biochemical strategies to adapt to the changing environmental gas availability. Structurally, most fish hemoglobins are tetrameric; however, those from some species such as lamprey and hagfish dissociate, being monomeric when oxygenated and oligomeric when deoxygenated. Fish blood frequently possesses several hemoglobins; the primary origin of this finding lies in the polymorphism that occurs in the globin loci, an aspect that may occasionally confer advantages to its carriers or even be a harmless evolutionary remnant. On the other hand, the functional properties exhibit different behaviors, ranging from a total absence of responses to allosteric regulation to drastic ones, such as the Root effect.

  16. Users satisfaction with electronic information resources and services ...

    This study investigated users satisfaction on the use of electronic information resources and services in MTN Net libraries in ABU & UNIBEN. Two objectives and one null hypotheses were formulated and tested with respect to the users' satisfaction on electronic information resources and services in MTN Net libraries in ...

  17. The Role of the Acquisitions Librarian in Electronic Resources Management

    Pomerantz, Sarah B.

    2010-01-01

    With the ongoing shift to electronic formats for library resources, acquisitions librarians, like the rest of the profession, must adapt to the rapidly changing landscape of electronic resources by keeping up with trends and mastering new skills related to digital publishing, technology, and licensing. The author sought to know what roles…

  18. Hemoglobin C disease

    Clinical hemoglobin C ... Hemoglobin C is an abnormal type of hemoglobin, the protein in red blood cells that carries oxygen. It is ... Americans. You are more likely to have hemoglobin C disease if someone in your family has had ...

  19. Selection and Evaluation of Electronic Resources

    Doğan Atılgan

    2013-11-01

    Full Text Available Publication boom and issues related to controlling and accession of printed sources have created some problems after World War II. Consequently, publishing industry has encountered the problem of finding possible solution for emerged situation. Industry of electronic publishing has started to improve with the rapid increase of the price of printed sources as well as the problem of publication boom. The first effects of electronic publishing were appeared on the academic and scholarly publications then electronic publishing became a crucial part of all types of publications. As a result of these developments, collection developments and service policies of information centers were also significantly changed. In this article, after a general introduction about selection and evaluation processes of electronic publications, the subscribed databases by a state and a privately owned university in Turkey and their usage were examined.

  20. Improving Electronic Resources through Holistic Budgeting

    Kusik, James P.; Vargas, Mark A.

    2009-01-01

    To establish a more direct link between its collections and the educational goals of Saint Xavier University, the Byrne Memorial Library has adopted a "holistic" approach to collection development. This article examines how traditional budget practices influenced the library's selection of resources and describes how holistic collection…

  1. Page 170 Use of Electronic Resources by Undergraduates in Two ...

    undergraduate students use electronic resources such as NUC virtual library, HINARI, ... web pages articles from magazines, encyclopedias, pamphlets and other .... of Nigerian university libraries have Internet connectivity, some of the system.

  2. Utilisation of Electronic Information Resources By Lecturers in ...

    This study assesses the use of information resources, specifically, electronic databases by lecturers/teachers in Universities and Colleges of Education in South Western Nigeria. Information resources are central to teachers' education. It provides lecturers/teachers access to information that enhances research and ...

  3. Preservation and conservation of electronic information resources of ...

    The major holdings of the broadcast libraries of the Nigerian Television Authority (NTA) are electronic information resources; therefore, providing safe places for general management of these resources have aroused interest in the industry in Nigeria for sometimes. The need to study the preservation and conservation of ...

  4. Using XML Technologies to Organize Electronic Reference Resources

    Huser, Vojtech; Del Fiol, Guilherme; Rocha, Roberto A.

    2005-01-01

    Provision of access to reference electronic resources to clinicians is becoming increasingly important. We have created a framework for librarians to manage access to these resources at an enterprise level, rather than at the individual hospital libraries. We describe initial project requirements, implementation details, and some preliminary results.

  5. Euler European Libraries and Electronic Resources in Mathematical Sciences

    The Euler Project. Karlsruhe

    The European Libraries and Electronic Resources (EULER) Project in Mathematical Sciences provides the EulerService site for searching out "mathematical resources such as books, pre-prints, web-pages, abstracts, proceedings, serials, technical reports preprints) and NetLab (for Internet resources), this outstanding engine is capable of simple, full, and refined searches. It also offers a browse option, which responds to entries in the author, keyword, and title fields. Further information about the Project is provided at the EULER homepage.

  6. Determining eligibility for antiretroviral therapy in resource-limited settings using total lymphocyte counts, hemoglobin and body mass index

    Solberg Peter

    2007-01-01

    Full Text Available Abstract Background CD4+ T lymphocyte (CD4 cell count testing is the standard method for determining eligibility for antiretroviral therapy (ART, but is not widely available in sub-Saharan Africa. Total lymphocyte counts (TLCs have not proven sufficiently accurate in identifying subjects with low CD4 counts. We developed clinical algorithms using TLCs, hemoglobin (Hb, and body mass index (BMI to identify patients who require ART. Methods We conducted a cross-sectional study of HIV-infected adults in Uganda, who presented for assessment for ART-eligibility with WHO clinical stages I, II or III. Two by two tables were constructed to examine TLC thresholds, which maximized sensitivity for CD4 cell counts ≤ 200 cells μL, while minimizing the number offered ART with counts > 350 cells μL. Hb and BMI values were then examined to try to improve model performance. Results 1787 subjects were available for analysis. Median CD4 cell counts and TLCs, were 239 cells/μL and 1830 cells/μL, respectively. Offering ART to all subjects with a TLCs ≤ 2250 cells/μL produced a sensitivity of 0.88 and a false positive ratio of 0.21. Algorithms that treated all patients with a TLC 3000 cells/μL, and used Hb and/or BMI values to determine eligibility for those with TLC values between 2000 and 3000 cells/μL, marginally improved accuracy. Conclusion TLCs appear useful in predicting who would be eligible for ART based on CD4 cell count criteria. Hb and BMI values may be useful in prioritizing patients for ART, but did not improve model accuracy.

  7. Building an electronic resource collection a practical guide

    Lee, Stuart D

    2004-01-01

    This practical book guides information professionals step-by-step through building and managing an electronic resource collection. It outlines the range of electronic products currently available in abstracting and indexing, bibliographic, and other services and then describes how to effectively select, evaluate and purchase them.

  8. Organizational matters of competition in electronic educational resources

    Ирина Карловна Войтович

    2015-12-01

    Full Text Available The article examines the experience of the Udmurt State University in conducting competitions of educational publications and electronic resources. The purpose of such competitions is to provide methodological support to educational process. The main focus is on competition of electronic educational resources. The technology of such contests is discussed through detailed analysis of the main stages of the contest. It is noted that the main task of the preparatory stage of the competition is related to the development of regulations on competition and the definition of criteria for selection of the submitted works. The paper also proposes a system of evaluation criteria of electronic educational resources developed by members of the contest organizing committee and jury members. The article emphasizes the importance of not only the preparatory stages of the competition, but also measures for its completion, aimed at training teachers create quality e-learning resources.

  9. Why and How to Measure the Use of Electronic Resources

    Jean Bernon

    2008-11-01

    Full Text Available A complete overview of library activity implies a complete and reliable measurement of the use of both electronic resources and printed materials. This measurement is based on three sets of definitions: document types, use types and user types. There is a common model of definitions for printed materials, but a lot of questions and technical issues remain for electronic resources. In 2006 a French national working group studied these questions. It relied on the COUNTER standard, but found it insufficient and pointed out the need for local tools such as web markers and deep analysis of proxy logs. Within the French national consortium COUPERIN, a new working group is testing ERMS, SUSHI standards, Shibboleth authentication, along with COUNTER standards, to improve the counting of the electronic resources use. At this stage this counting is insufficient and its improvement will be a European challenge for the future.

  10. Access to electronic resources by visually impaired people

    Jenny Craven

    2003-01-01

    Full Text Available Research into access to electronic resources by visually impaired people undertaken by the Centre for Research in Library and Information Management has not only explored the accessibility of websites and levels of awareness in providing websites that adhere to design for all principles, but has sought to enhance understanding of information seeking behaviour of blind and visually impaired people when using digital resources.

  11. Practical guide to electronic resources in the humanities

    Dubnjakovic, Ana

    2010-01-01

    From full-text article databases to digitized collections of primary source materials, newly emerging electronic resources have radically impacted how research in the humanities is conducted and discovered. This book, covering high-quality, up-to-date electronic resources for the humanities, is an easy-to-use annotated guide for the librarian, student, and scholar alike. It covers online databases, indexes, archives, and many other critical tools in key humanities disciplines including philosophy, religion, languages and literature, and performing and visual arts. Succinct overviews of key eme

  12. Discipline, availability of electronic resources and the use of Finnish National Electronic Library - FinELib

    Sanna Torma

    2004-01-01

    Full Text Available This study elaborated relations between digital library use by university faculty, users' discipline and the availability of key resources in the Finnish National Electronic Library (FinELib, Finnish national digital library, by using nationwide representative survey data. The results show that the perceived availability of key electronic resources by researchers in FinELib was a stronger predictor of the frequency and purpose of use of its services than users' discipline. Regardless of discipline a good perceived provision of central resources led to a more frequent use of FinELib. The satisfaction with the services did not vary with the discipline, but with the perceived availability of resources.

  13. Access to electronic information resources by students of federal ...

    The paper discusses access to electronic information resources by students of Federal Colleges of Education in Eha-Amufu and Umunze. Descriptive survey design was used to investigate sample of 526 students. Sampling technique used was a Multi sampling technique. Data for the study were generated using ...

  14. Electronic Commerce Resource Centers. An Industry--University Partnership.

    Gulledge, Thomas R.; Sommer, Rainer; Tarimcilar, M. Murat

    1999-01-01

    Electronic Commerce Resource Centers focus on transferring emerging technologies to small businesses through university/industry partnerships. Successful implementation hinges on a strategic operating plan, creation of measurable value for customers, investment in customer-targeted training, and measurement of performance outputs. (SK)

  15. ANALYTICAL REVIEW OF ELECTRONIC RESOURCES FOR THE STUDY OF LATIN

    Olena Yu. Balalaieva

    2014-04-01

    Full Text Available The article investigates the current state of development of e-learning content in the Latin language. It is noted that the introduction of ICT in the educational space has expanded the possibility of studying Latin, opened access to digital libraries resources, made it possible to use scientific and educational potential and teaching Latin best practices of world's leading universities. A review of foreign and Ukrainian information resources and electronic editions for the study of Latin is given. Much attention was paid to the didactic potential of local and online multimedia courses of Latin, electronic textbooks, workbooks of interactive tests and exercises, various dictionaries and software translators, databases and digital libraries. Based on analysis of the world market of educational services and products the main trends in the development of information resources and electronic books are examined. It was found that multimedia courses with interactive exercises or workbooks with interactive tests, online dictionaries and translators are the most widely represented and demanded. The noticeable lagging of Ukrainian education and computer linguistics in quantitative and qualitative measures in this industry is established. The obvious drawback of existing Ukrainian resources and electronic editions for the study of Latin is their noninteractive nature. The prospects of e-learning content in Latin in Ukraine are outlined.

  16. Adoption and use of electronic information resources by medical ...

    This study investigated the adoption and use of electronic information resources by medical science students of the University of Benin. The descriptive survey research design was adopted for the study and 390 students provided the data. Data collected were analysed with descriptive Statistics(Simple percentage and ...

  17. Modern ICT Tools: Online Electronic Resources Sharing Using Web ...

    Modern ICT Tools: Online Electronic Resources Sharing Using Web 2.0 and Its Implications For Library And Information Practice In Nigeria. ... The PDF file you selected should load here if your Web browser has a PDF reader plug-in installed (for example, a recent version of Adobe Acrobat Reader). If you would like more ...

  18. Technical Communicator: A New Model for the Electronic Resources Librarian?

    Hulseberg, Anna

    2016-01-01

    This article explores whether technical communicator is a useful model for electronic resources (ER) librarians. The fields of ER librarianship and technical communication (TC) originated and continue to develop in relation to evolving technologies. A review of the literature reveals four common themes for ER librarianship and TC. While the…

  19. A novel nitrite biosensor based on the direct electron transfer hemoglobin immobilized in the WO3 nanowires with high length–diameter ratio

    Liu, Hui; Duan, Congyue; Yang, Chenhui; Chen, Xianjin; Shen, Wanqiu; Zhu, Zhenfeng

    2015-01-01

    WO 3 nanowires (WO 3 NWs) with high length–diameter ratio have been synthesized through a simple synthetic route without any additive and then used to immobilize hemoglobin (Hb) to fabricate a mediator-free biosensor. The morphology and structure of WO 3 NWs were characterized by scanning electron microscopy, transmission electronic microscopy and X-ray diffraction. Spectroscopic and electrochemical results revealed that WO 3 NWs are an excellent immobilization matrix with biocompatibility for redox protein, affording good protein bioactivity and stability. Meanwhile, due to unique morphology and property of the WO 3 nanowires, the direct electron transfer of Hb is facilitated and the prepared biosensors displayed good performance for the detection of nitrite with a wide linear range of 1 to 4200 μM, as well as an extremely low detection limit of 0.28 μM. The WO 3 nanowires with high length–diameter ratio could be a promising matrix for the fabrication of mediator-free biosensors, and may find wide potential applications in environmental analysis and biomedical detection. - Highlights: • The WO 3 NWs with high length–diameter ratio have been synthesized. • The WO 3 NWs were used to immobilize Hb to fabricate a mediator-free biosensor. • The biosensor displays a wide linear range of 1–4200 μM for nitrite. • The biosensor exhibits an extremely low detection limit of 0.28 μM for nitrite

  20. Measuring Post-Partum Haemorrhage in Low-Resource Settings: The Diagnostic Validity of Weighed Blood Loss versus Quantitative Changes in Hemoglobin.

    Esther Cathyln Atukunda

    Full Text Available Accurate estimation of blood loss is central to prompt diagnosis and management of post-partum hemorrhage (PPH, which remains a leading cause of maternal mortality in low-resource countries. In such settings, blood loss is often estimated visually and subjectively by attending health workers, due to inconsistent availability of laboratory infrastructure. We evaluated the diagnostic accuracy of weighed blood loss (WBL versus changes in peri-partum hemoglobin to detect PPH.Data from this analysis were collected as part of a randomized controlled trial comparing oxytocin with misoprostol for PPH (NCT01866241. Blood samples for complete blood count were drawn on admission and again prior to hospital discharge or before blood transfusion. During delivery, women were placed on drapes and had pre-weighed sanitary towels placed around their perineum. Blood was then drained into a calibrated container and the sanitary towels were added to estimate WBL, where each gram of blood was estimated as a milliliter. Sensitivity, specificity, negative and positive predictive values (PPVs were calculated at various blood volume loss and time combinations, and we fit receiver-operator curves using blood loss at 1, 2, and 24 hours compared to a reference standard of haemoglobin decrease of >10%.A total of 1,140 women were enrolled in the study, of whom 258 (22.6% developed PPH, defined as a haemoglobin drop >10%, and 262 (23.0% had WBL ≥500mL. WBL generally had a poor sensitivity for detection of PPH (85% in high prevalence settings when WBL exceeds 750mL.WBL has poor sensitivity but high specificity compared to laboratory-based methods of PPH diagnosis. These characteristics correspond to a high PPV in areas with high PPH prevalence. Although WBL is not useful for excluding PPH, this low-cost, simple and reproducible method is promising as a reasonable method to identify significant PPH in such settings where quantifiable red cell indices are unavailable.

  1. MODEL OF AN ELECTRONIC EDUCATIONAL RESOURCE OF NEW GENERATION

    Anatoliy V. Loban

    2016-01-01

    Full Text Available The mathematical structure of the modular architecture of an electronic educational resource (EER of new generation, which allows to decompose the process of studying the subjects of the course at a hierarchically ordered set of data (knowledge and procedures for manipulating them, to determine the roles of participants of process of training of and technology the development and use of EOR in the study procrate.

  2. A novel nitrite biosensor based on the direct electron transfer hemoglobin immobilized in the WO{sub 3} nanowires with high length–diameter ratio

    Liu, Hui, E-mail: liuhui@sust.edu.cn; Duan, Congyue; Yang, Chenhui; Chen, Xianjin; Shen, Wanqiu; Zhu, Zhenfeng

    2015-08-01

    WO{sub 3} nanowires (WO{sub 3}NWs) with high length–diameter ratio have been synthesized through a simple synthetic route without any additive and then used to immobilize hemoglobin (Hb) to fabricate a mediator-free biosensor. The morphology and structure of WO{sub 3}NWs were characterized by scanning electron microscopy, transmission electronic microscopy and X-ray diffraction. Spectroscopic and electrochemical results revealed that WO{sub 3}NWs are an excellent immobilization matrix with biocompatibility for redox protein, affording good protein bioactivity and stability. Meanwhile, due to unique morphology and property of the WO{sub 3} nanowires, the direct electron transfer of Hb is facilitated and the prepared biosensors displayed good performance for the detection of nitrite with a wide linear range of 1 to 4200 μM, as well as an extremely low detection limit of 0.28 μM. The WO{sub 3} nanowires with high length–diameter ratio could be a promising matrix for the fabrication of mediator-free biosensors, and may find wide potential applications in environmental analysis and biomedical detection. - Highlights: • The WO{sub 3}NWs with high length–diameter ratio have been synthesized. • The WO{sub 3}NWs were used to immobilize Hb to fabricate a mediator-free biosensor. • The biosensor displays a wide linear range of 1–4200 μM for nitrite. • The biosensor exhibits an extremely low detection limit of 0.28 μM for nitrite.

  3. Direct electron transfer of hemoglobin immobilized in a mesocellular siliceous foams supported room temperature ionic liquid matrix and the electrocatalytic reduction of H2O2

    Yu Jingjing; Zhao Tian; Zhao Faqiong; Zeng Baizhao

    2008-01-01

    Room temperature ionic liquid (RTIL) 1-butyl-3-methylimidazolium hexafluorophosphate (BMIM.PF 6 ) has been successfully immobilized on mesocellular siliceous foams (MSFs) by using a specific annealing method. Nitrogen adsorption/desorption isotherms and scanning electron microscopy (SEM) images reveal that most pores of MSFs are filled with the RTIL and the outer surfaces of MSFs are covered with the RTIL. When hemoglobin (Hb) is immobilized with the resulting hybrid material on a glassy carbon electrode (GCE), a pair of well-defined and quasi-reversible voltammetric peaks for Hb Fe(III)/Fe(II) is obtained. Its formal potential is -0.330 V (vs. saturated calomel electrode) in pH 7.0 phosphate buffer solution (PBS). The peak currents are much larger than those of Hb immobilized with MSFs or BMIM.PF 6 -MSFs mixture. This indicates that the hybrid material has stronger promotion to the direct electron transfer of Hb, which is related to the effective immobilization of BMIM.PF 6 on MSFs. The electron-transfer rate constant (k s ) is estimated to be 1.91 s -1 . The immobilized Hb retains its native conformation and shows high electrocatalysis to the reduction of H 2 O 2 . Under the optimized experimental conditions, the catalytic current is linear to the concentration of H 2 O 2 from 0.2 to 28 μM, and the detection limit is 8 x 10 -8 M (S/N = 3). The linear range is wider than those for Hb immobilized with MSFs or BMIM.PF 6 -MSFs mixture. Thus, the MSFs supported RTILs hybrid material is an ideal matrix for protein immobilization and biosensor fabrication

  4. End-of-life resource recovery from emerging electronic products

    Parajuly, Keshav; Habib, Komal; Cimpan, Ciprian

    2016-01-01

    Integrating product design with appropriate end-of-life (EoL) processing is widely recognized to have huge potentials in improving resource recovery from electronic products. In this study, we investigate both the product characteristics and EoL processing of robotic vacuum cleaner (RVC), as a case...... of emerging electronic product, in order to understand the recovery fate of different materials and its linkage to product design. Ten different brands of RVC were dismantled and their material composition and design profiles were studied. Another 125 RVCs (349 kg) were used for an experimental trial...... at a conventional ‘shred-and-separate’ type preprocessing plant in Denmark. A detailed material flow analysis was performed throughout the recycling chain. The results show a mismatch between product design and EoL processing, and the lack of practical implementation of ‘Design for EoL’ thinking. In the best...

  5. Analysis of Human Resources Management Strategy in China Electronic Commerce Enterprises

    Shao, Fang

    The paper discussed electronic-commerce's influence on enterprise human resources management, proposed and proved the human resources management strategy which electronic commerce enterprise should adopt from recruitment strategy to training strategy, keeping talent strategy and other ways.

  6. Investigation of the hyperfine properties of deoxy hemoglobin based on its electronic structure obtained by Hartree-Fock-Roothan procedure

    Lata, K. Ramani [State University of New York at Albany, Department of Physics (United States); Sahoo, N. [University of Texas M.D. Anderson Cancer Center, Department of Radiation Physics (United States); Dubey, Archana [University of Central Florida, Department of Physics (United States); Scheicher, R. H. [Uppsala University, Condensed Matter Theory Group, Department of Physics and Materials Science (Sweden); Badu, S. R.; Pink, R. H.; Mahato, Dip N. [State University of New York at Albany, Department of Physics (United States); Schulte, A. F.; Saha, H. P. [University of Central Florida, Department of Physics (United States); Maharjan, N. B. [State University of New York at Albany, Department of Physics (United States); Chow, Lee [University of Central Florida, Department of Physics (United States); Das, T. P., E-mail: tpd56@albany.edu [State University of New York at Albany, Department of Physics (United States)

    2008-01-15

    The electronic structure of the heme unit of deoxyhemoglobin including the proximal imidazole has been studied using the first-principles Hartree-Fock procedure. Our results for the {sup 57m}Fe isomer shift and asymmetry parameter are in very good agreement with the values obtained from Moessbauer spectroscopy measurements. The {sup 57m}Fe nuclear quadrupole coupling constant is smaller than the experimental result and possible ways to improve the agreement in the future are discussed. Improved analysis of the Moessbauer data, removing some approximations made for deriving the magnetic hyperfine tensor for the {sup 57m}Fe nucleus, is suggested to allow quantitative comparison with our results in the future.

  7. Effects of Electronic Information Resources Skills Training for Lecturers on Pedagogical Practices and Research Productivity

    Bhukuvhani, Crispen; Chiparausha, Blessing; Zuvalinyenga, Dorcas

    2012-01-01

    Lecturers use various electronic resources at different frequencies. The university library's information literacy skills workshops and seminars are the main sources of knowledge of accessing electronic resources. The use of electronic resources can be said to have positively affected lecturers' pedagogical practices and their work in general. The…

  8. Electronic Resources and Mission Creep: Reorganizing the Library for the Twenty-First Century

    Stachokas, George

    2009-01-01

    The position of electronic resources librarian was created to serve as a specialist in the negotiation of license agreements for electronic resources, but mission creep has added more functions to the routine work of electronic resources such as cataloging, gathering information for collection development, and technical support. As electronic…

  9. Spectroscopic study of gamma irradiated bovine hemoglobin

    Maghraby, Ahmed Mohamed; Ali, Maha Anwar

    2007-01-01

    In the present study, the effects of ionizing radiation of Cs-137 and Co-60 from 4.95 to 743.14 Gy and from 40 Gy to 300 kGy, respectively, on some bovine hemoglobin characteristics were studied. Such an effect was evaluated using electron paramagnetic resonance (EPR) spectroscopy, and infra-red (IR) spectroscopy. Bovine hemoglobin EPR spectra were recorded and analyzed before and after irradiation and changes were explained in detail. IR spectra of unirradiated and irradiated Bovine hemoglobin were recorded and analyzed also. It was found that ionizing radiation may lead to the increase of free radicals production, the decrease in α-helices contents, which reflects the degradation of hemoglobin molecular structure, or at least its incomplete performance. Results also show that the combined application of EPR and FTIR spectroscopy is a powerful tool for determining structural modification of bovine hemoglobin samples exposed to gamma irradiation

  10. Electronic Document Management: A Human Resource Management Case Study

    Thomas Groenewald

    2004-11-01

    Full Text Available This case study serve as exemplar regarding what can go wrong with the implementation of an electronic document management system. Knowledge agility and knowledge as capital, is outlined against the backdrop of the information society and knowledge economy. The importance of electronic document management and control is sketched thereafter. The literature review is concluded with the impact of human resource management on knowledge agility, which includes references to the learning organisation and complexity theory. The intervention methodology, comprising three phases, follows next. The results of the three phases are presented thereafter. Partial success has been achieved with improving the human efficacy of electronic document management, however the client opted to discontinue the system in use. Opsomming Die gevalle studie dien as voorbeeld van wat kan verkeerd loop met die implementering van ’n elektroniese dokumentbestuur sisteem. Teen die agtergrond van die inligtingsgemeenskap en kennishuishouding word kennissoepelheid en kennis as kapitaal bespreek. Die literatuurstudie word afgesluit met die inpak van menslikehulpbronbestuur op kennissoepelheid, wat ook die verwysings na die leerorganisasie en kompleksietydsteorie insluit. Die metodologie van die intervensie, wat uit drie fases bestaan, volg daarna. Die resultate van die drie fases word vervolgens aangebied. Slegs gedeelte welslae is behaal met die verbetering van die menslike doeltreffendheid ten opsigte van elektroniese dokumentbestuur. Die klient besluit egter om nie voort te gaan om die huidige sisteem te gebruik nie.

  11. The Hemoglobin E Thalassemias

    Fucharoen, Suthat; Weatherall, David J.

    2012-01-01

    Hemoglobin E (HbE) is an extremely common structural hemoglobin variant that occurs at high frequencies throughout many Asian countries. It is a β-hemoglobin variant, which is produced at a slightly reduced rate and hence has the phenotype of a mild form of β thalassemia. Its interactions with different forms of α thalassemia result in a wide variety of clinical disorders, whereas its coinheritance with β thalassemia, a condition called hemoglobin E β thalassemia, is by far the most common severe form of β thalassemia in Asia and, globally, comprises approximately 50% of the clinically severe β-thalassemia disorders. PMID:22908199

  12. Comparative analysis of the heme iron electronic structure and stereochemistry in tetrameric rabbit hemoglobin and monomeric soybean leghemoglobin a using Mössbauer spectroscopy with a high velocity resolution

    Alenkina, I. V.; Kumar, A.; Berkovsky, A. L.; Oshtrakh, M. I.

    2018-02-01

    A comparative study of tetrameric rabbit hemoglobin and monomeric soybean leghemoglobin a in the oxy- and deoxy-forms was carried out using 57Fe Mössbauer spectroscopy with a high velocity resolution in order to analyze the heme iron electronic structure and stereochemistry in relation to the Mössbauer hyperfine parameters. The Mössbauer spectra of tetrameric rabbit hemoglobin in both forms were fitted using two quadrupole doublets related to the 57Fe in ɑ- and β-subunits. In contrast, the Mössbauer spectra of monomeric soybean leghemoglobin a were fitted using: (i) two quadrupole doublets for the oxy-form related to two conformational states of the distal His E7 imidazole ring and different hydrogen bonding of oxygen molecule in the oxy-form and (ii) using three quadrupole doublets for deoxy-form related to three conformational states of the proximal His F8 imidazole ring. Small variations of Mössbauer hyperfine parameters related to small differences in the heme iron electronic structure and stereochemistry in tetrameric rabbit hemoglobin and monomeric soybean leghemoglobin a are discussed.

  13. Electronic Safety Resource Tools -- Supporting Hydrogen and Fuel Cell Commercialization

    Barilo, Nick F.

    2014-09-29

    The Pacific Northwest National Laboratory (PNNL) Hydrogen Safety Program conducted a planning session in Los Angeles, CA on April 1, 2014 to consider what electronic safety tools would benefit the next phase of hydrogen and fuel cell commercialization. A diverse, 20-person team led by an experienced facilitator considered the question as it applied to the eight most relevant user groups. The results and subsequent evaluation activities revealed several possible resource tools that could greatly benefit users. The tool identified as having the greatest potential for impact is a hydrogen safety portal, which can be the central location for integrating and disseminating safety information (including most of the tools identified in this report). Such a tool can provide credible and reliable information from a trustworthy source. Other impactful tools identified include a codes and standards wizard to guide users through a series of questions relating to application and specific features of the requirements; a scenario-based virtual reality training for first responders; peer networking tools to bring users from focused groups together to discuss and collaborate on hydrogen safety issues; and a focused tool for training inspectors. Table ES.1 provides results of the planning session, including proposed new tools and changes to existing tools.

  14. Controlling user access to electronic resources without password

    Smith, Fred Hewitt

    2015-06-16

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes pre-determining an association of the restricted computer resource and computer-resource-proximal environmental information. Indicia of user-proximal environmental information are received from a user requesting access to the restricted computer resource. Received indicia of user-proximal environmental information are compared to associated computer-resource-proximal environmental information. User access to the restricted computer resource is selectively granted responsive to a favorable comparison in which the user-proximal environmental information is sufficiently similar to the computer-resource proximal environmental information. In at least some embodiments, the process further includes comparing user-supplied biometric measure and comparing it with a predetermined association of at least one biometric measure of an authorized user. Access to the restricted computer resource is granted in response to a favorable comparison.

  15. The Internet School of Medicine: use of electronic resources by medical trainees and the reliability of those resources.

    Egle, Jonathan P; Smeenge, David M; Kassem, Kamal M; Mittal, Vijay K

    2015-01-01

    Electronic sources of medical information are plentiful, and numerous studies have demonstrated the use of the Internet by patients and the variable reliability of these sources. Studies have investigated neither the use of web-based resources by residents, nor the reliability of the information available on these websites. A web-based survey was distributed to surgical residents in Michigan and third- and fourth-year medical students at an American allopathic and osteopathic medical school and a Caribbean allopathic school regarding their preferred sources of medical information in various situations. A set of 254 queries simulating those faced by medical trainees on rounds, on a written examination, or during patient care was developed. The top 5 electronic resources cited by the trainees were evaluated for their ability to answer these questions accurately, using standard textbooks as the point of reference. The respondents reported a wide variety of overall preferred resources. Most of the 73 responding medical trainees favored textbooks or board review books for prolonged studying, but electronic resources are frequently used for quick studying, clinical decision-making questions, and medication queries. The most commonly used electronic resources were UpToDate, Google, Medscape, Wikipedia, and Epocrates. UpToDate and Epocrates had the highest percentage of correct answers (47%) and Wikipedia had the lowest (26%). Epocrates also had the highest percentage of wrong answers (30%), whereas Google had the lowest percentage (18%). All resources had a significant number of questions that they were unable to answer. Though hardcopy books have not been completely replaced by electronic resources, more than half of medical students and nearly half of residents prefer web-based sources of information. For quick questions and studying, both groups prefer Internet sources. However, the most commonly used electronic resources fail to answer clinical queries more than half

  16. Phylogeny of Echinoderm Hemoglobins.

    Ana B Christensen

    Full Text Available Recent genomic information has revealed that neuroglobin and cytoglobin are the two principal lineages of vertebrate hemoglobins, with the latter encompassing the familiar myoglobin and α-globin/β-globin tetramer hemoglobin, and several minor groups. In contrast, very little is known about hemoglobins in echinoderms, a phylum of exclusively marine organisms closely related to vertebrates, beyond the presence of coelomic hemoglobins in sea cucumbers and brittle stars. We identified about 50 hemoglobins in sea urchin, starfish and sea cucumber genomes and transcriptomes, and used Bayesian inference to carry out a molecular phylogenetic analysis of their relationship to vertebrate sequences, specifically, to assess the hypothesis that the neuroglobin and cytoglobin lineages are also present in echinoderms.The genome of the sea urchin Strongylocentrotus purpuratus encodes several hemoglobins, including a unique chimeric 14-domain globin, 2 androglobin isoforms and a unique single androglobin domain protein. Other strongylocentrotid genomes appear to have similar repertoires of globin genes. We carried out molecular phylogenetic analyses of 52 hemoglobins identified in sea urchin, brittle star and sea cucumber genomes and transcriptomes, using different multiple sequence alignment methods coupled with Bayesian and maximum likelihood approaches. The results demonstrate that there are two major globin lineages in echinoderms, which are related to the vertebrate neuroglobin and cytoglobin lineages. Furthermore, the brittle star and sea cucumber coelomic hemoglobins appear to have evolved independently from the cytoglobin lineage, similar to the evolution of erythroid oxygen binding globins in cyclostomes and vertebrates.The presence of echinoderm globins related to the vertebrate neuroglobin and cytoglobin lineages suggests that the split between neuroglobins and cytoglobins occurred in the deuterostome ancestor shared by echinoderms and vertebrates.

  17. Developing Humanities Collections in the Digital Age: Exploring Humanities Faculty Engagement with Electronic and Print Resources

    Kachaluba, Sarah Buck; Brady, Jessica Evans; Critten, Jessica

    2014-01-01

    This article is based on quantitative and qualitative research examining humanities scholars' understandings of the advantages and disadvantages of print versus electronic information resources. It explores how humanities' faculty members at Florida State University (FSU) use print and electronic resources, as well as how they perceive these…

  18. Electronic resource management practical perspectives in a new technical services model

    Elguindi, Anne

    2012-01-01

    A significant shift is taking place in libraries, with the purchase of e-resources accounting for the bulk of materials spending. Electronic Resource Management makes the case that technical services workflows need to make a corresponding shift toward e-centric models and highlights the increasing variety of e-formats that are forcing new developments in the field.Six chapters cover key topics, including: technical services models, both past and emerging; staffing and workflow in electronic resource management; implementation and transformation of electronic resource management systems; the ro

  19. Electronic resources access and usage among the postgraduates of ...

    ... and usage among the postgraduates of a Nigerian University of Technology. ... faced by postgraduates in using e-resources include takes too much time to find, ... Resources, Access, Use, Postgraduat, Students, University, Technology, Nigeria ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  20. Strategic Planning for Electronic Resources Management: A Case Study at Gustavus Adolphus College

    Hulseberg, Anna; Monson, Sarah

    2009-01-01

    Electronic resources, the tools we use to manage them, and the needs and expectations of our users are constantly evolving; at the same time, the roles, responsibilities, and workflow of the library staff who manage e-resources are also in flux. Recognizing a need to be more intentional and proactive about how we manage e-resources, the…

  1. impact of the use of electronic resources on research output

    manda

    ... Julita Nawe. University of Dar Es Salaam Library, P.O. Box 35092, Dar Es Salaam, Tanzania .... significantly, while 28.3% observed that quality of service to the community had improved .... resources and evaluate them is an important area.

  2. Preservation of and Permanent Access to Electronic Information Resources

    Hodge, Gail

    2004-01-01

    The rapid growth in the creation and dissemination of electronic information has emphasized the digital environment's speed and ease of dissemination with little regard for its long-term preservation and access...

  3. Electronic conferencing for continuing medical education: a resource survey.

    Sternberg, R J

    1986-10-01

    The use of electronic technologies to link participants for education conferences is an option for providers of Continuing Medical Education. In order to profile the kinds of electronic networks currently offering audio- or videoteleconferences for physician audiences, a survey was done during late 1985. The information collected included range of services, fees, and geographic areas served. The results show a broad diversity of providers providing both interactive and didactic programming to both physicians and other health care professionals.

  4. Controlling user access to electronic resources without password

    Smith, Fred Hewitt

    2017-08-22

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes obtaining an image from a communication device of a user. An individual and a landmark are identified within the image. Determinations are made that the individual is the user and that the landmark is a predetermined landmark. Access to a restricted computing resource is granted based on the determining that the individual is the user and that the landmark is the predetermined landmark. Other embodiments are disclosed.

  5. Rice (Oryza) hemoglobins

    Hemoglobins (Hbs) corresponding to non-symbiotic (nsHb) and truncated (tHb) Hbs have been identified in rice (Oryza). This review discusses the major findings from the current studies on rice Hbs. At the molecular level, a family of the nshb genes, consisting of hb1, hb2, hb3, hb4 and hb5, and a sin...

  6. Electron beam pasteurised oil palm waste: a potential feed resource

    Mat Rasol Awang; Hassan Hamdani Mutaat; Tamikazu Kume; Tachibana, H.

    2002-01-01

    Pasteurization of oil palm empty fruit bunch (EFB) was performed using electron beam single sided irradiation. The dose profiles of oil palm EFB samples for different thickness in both directions X and Y were established. The results showed the usual characteristics dose uniformity as sample thickness decreased. The mean average absorbed dose on both sides at the surface and bottom of the samples for different thickness samples lead to establishing depth dose curve. Based on depth dose curve and operation conditions of electron beam machine, the process throughput for pasteurized oil palm EFB were estimated. (Author)

  7. Availability of Electronic Resources for Service Provision in ...

    The study also revealed that majority of the University libraries have adequate basic infrastructure for effective electronic information services. ... acquired by the library are put into maximal use by the library clientele, thereby ensuring the achievement of the library's objective which is satisfying the users, information needs.

  8. Utilization of bio-resources by low energy electron beam

    Kume, Tamikazu

    2003-01-01

    Utilization of bio-resources by radiation has been investigated for recycling the natural resources and reducing the environmental pollution. Polysaccharides such as chitosan and sodium alginate were easily degraded by irradiation and induced various kinds of biological activities, i.g. anti-microbial activity, promotion of plant growth, suppression of heavy metal stress, phytoalexins induction. Radiation degraded chitosan was effective to enhance the growth of plants in tissue culture. It was demonstrated that the liquid sample irradiation system using low energy EB was effective for the preparation of degraded polysaccharides. Methylcellulose (MC) can be crosslinked under certain radiation condition as same as carboxymethylcellulose (CMC) and produced the biodegradable hydrogel for medical and agricultural use. Treatment of soybean seeds by low energy EB enhanced the growth and the number of rhizobia on the root. (author)

  9. Analysis of Pedagogic Potential of Electronic Educational Resources with Elements of Autodidactics

    Igor A.

    2018-03-01

    Full Text Available Introduction: in recent years didactic properties of electronic educational resources undergo considerable changes, nevertheless, the question of studying of such complete phenomenon as “an electronic educational resource with autodidactics elements” remains open, despite sufficient scientific base of researches of the terms making this concept. Article purpose – determination of essence of electronic educational resources with autodidactics elements. Materials and Methods: the main method of research was the theoretical analysis of the pedagogical and psychological literature on the problem under study. We used the theoretical (analysis, synthesis, comparison and generalization methods, the method of interpretation, pedagogical modeling, and empirical methods (observation, testing, conversation, interview, analysis of students’ performance, pedagogical experiment, peer review. Results: we detected the advantages of electronic educational resources in comparison with traditional ones. The concept of autodidactics as applied to the subject of research is considered. Properties of electronic educational resources with a linear and nonlinear principle of construction are studied.The influence of the principle of construction on the development of the learners’ qualities is shown. We formulated an integral definition of electronic educational resources with elements of autodidactics, namely, the variability, adaptivity and cyclicity of training. A model of the teaching-learning process with electronic educational resources is developed. Discussion and Conclusions: further development of a problem will allow to define whether electronic educational resources with autodidactics elements pedagogical potential for realization of educational and self-educational activity of teachers have, to modify technological procedures taking into account age features of students, their specialties and features of the organization of process of training of

  10. A Study on Developing Evaluation Criteria for Electronic Resources in Evaluation Indicators of Libraries

    Noh, Younghee

    2010-01-01

    This study aimed to improve the current state of electronic resource evaluation in libraries. While the use of Web DB, e-book, e-journal, and other e-resources such as CD-ROM, DVD, and micro materials is increasing in libraries, their use is not comprehensively factored into the general evaluation of libraries and may diminish the reliability of…

  11. Managing Selection for Electronic Resources: Kent State University Develops a New System to Automate Selection

    Downey, Kay

    2012-01-01

    Kent State University has developed a centralized system that manages the communication and work related to the review and selection of commercially available electronic resources. It is an automated system that tracks the review process, provides selectors with price and trial information, and compiles reviewers' feedback about the resource. It…

  12. Where Do Electronic Books Fit in the College Research Arsenal of Resources?

    Barbier, Patricia

    2007-01-01

    Student use of electronic books has become an accepted supplement to traditional resources. Student use and satisfaction was monitored through an online course discussion board. Increased use of electronic books indicate this service is an accepted supplement to the print book collection.

  13. The National Site Licensing of Electronic Resources: An Institutional Perspective

    Xiaohua Zhu

    2011-06-01

    Full Text Available While academic libraries in most countries are struggling to negotiate with publishers and vendors individually or collaboratively via consortia, a few countries have experimented with a different model, national site licensing (NSL. Because NSL often involves government and large-scale collaboration, it has the potential to solve many problems in the complex licensing world. However, not many nations have adopted it. This study uses historical research approach and the comparative case study research method to explore the seemingly low level of adoption. The cases include the Canadian National Site Licensing Project (CNSLP, the United Kingdom’s National Electronic Site Licensing Initiative (NESLI, and the United States, which has not adopted NSL. The theoretical framework guiding the research design and data collection is W. Richard Scott’s institutional theory, which utilizes three supporting pillars—regulative, normative, and cultural-cognitive—to analyze institutional processes. In this study, the regulative pillar and the normative pillar of NSL adoption— an institutional construction and change—are examined. Data were collected from monographs, research articles, government documents, and relevant websites. Based on the analysis of these cases, a preliminary model is proposed for the adoption of NSL. The factors that support a country’s adoption of NSL include the need for new institutions, a centralized educational policy-making system and funding system, supportive political trends, and the tradition of cooperation. The factors that may prevent a country from adopting NSL include decentralized educational policy and funding, diversity and the large number of institutions, the concern for the “Big Deal,” and the concern for monopoly.

  14. A survey of the use of electronic scientific information resources among medical and dental students

    Aarnio Matti

    2006-05-01

    Full Text Available Abstract Background To evaluate medical and dental students' utilization of electronic information resources. Methods A web survey sent to 837 students (49.9% responded. Results Twenty-four per cent of medical students and ninteen per cent of dental students searched MEDLINE 2+ times/month for study purposes, and thiry-two per cent and twenty-four per cent respectively for research. Full-text articles were used 2+ times/month by thirty-three per cent of medical and ten per cent of dental students. Twelve per cent of respondents never utilized either MEDLINE or full-text articles. In multivariate models, the information-searching skills among students were significantly associated with use of MEDLINE and full-text articles. Conclusion Use of electronic resources differs among students. Forty percent were non-users of full-text articles. Information-searching skills are correlated with the use of electronic resources, but the level of basic PC skills plays not a major role in using these resources. The student data shows that adequate training in information-searching skills will increase the use of electronic information resources.

  15. Analytical Study of Usage of Electronic Information Resources at Pharmacopoeial Libraries in India

    Sunil Tyagi

    2014-02-01

    Full Text Available The objective of this study is to know the rate and purpose of the use of e-resource by the scientists at pharmacopoeial libraries in India. Among other things, this study examined the preferences of the scientists toward printed books and journals, electronic information resources, and pattern of using e-resources. Non-probability sampling specially accidental and purposive technique was applied in the collection of primary data through administration of user questionnaire. The sample respondents chosen for the study consists of principle scientific officer, senior scientific officer, scientific officer, and scientific assistant of different division of the laboratories, namely, research and development, pharmaceutical chemistry, pharmacovigilance, pharmacology, pharmacogonosy, and microbiology. The findings of the study reveal the personal experiences and perceptions they have had on practice and research activity using e-resource. The major findings indicate that of the total anticipated participants, 78% indicated that they perceived the ability to use computer for electronic information resources. The data analysis shows that all the scientists belonging to the pharmacopoeial libraries used electronic information resources to address issues relating to drug indexes and compendia, monographs, drugs obtained through online databases, e-journals, and the Internet sources—especially polices by regulatory agencies, contacts, drug promotional literature, and standards.

  16. Considering Point-of-Care Electronic Medical Resources in Lieu of Traditional Textbooks for Medical Education.

    Hale, LaDonna S; Wallace, Michelle M; Adams, Courtney R; Kaufman, Michelle L; Snyder, Courtney L

    2015-09-01

    Selecting resources to support didactic courses is a critical decision, and the advantages and disadvantages must be carefully considered. During clinical rotations, students not only need to possess strong background knowledge but also are expected to be proficient with the same evidence-based POC resources used by clinicians. Students place high value on “real world” learning and therefore may place more value on POC resources that they know practicing clinicians use as compared with medical textbooks. The condensed nature of PA education requires students to develop background knowledge and information literacy skills over a short period. One way to build that knowledge and those skills simultaneously is to use POC resources in lieu of traditional medical textbooks during didactic training. Electronic POC resources offer several advantages over traditional textbooks and should be considered as viable options in PA education.

  17. Elektronik Bilgi Kaynaklarının Seçimi / Selection of Electronic Information Resources

    Pınar Al

    2003-04-01

    Full Text Available For many years, library users have used only from the printed media in order to get the information that they have needed. Today with the widespread use of the Web and the addition of electronic information resources to library collections, the use of information in the electronic environment as well as in printed media is started to be used. In time, such types of information resources as, electronic journals, electronic books, electronic encyclopedias, electronic dictionaries and electronic theses have been added to library collections. In this study, selection criteria that can be used for electronic information resources are discussed and suggestions are provided for libraries that try to select electronic information resources for their collections.

  18. Kadar Hemoglobin dan Kecerdasan Intelektual Anak

    Yuni Kusmiyati

    2013-10-01

    Full Text Available Kualitas sumber daya manusia dipengaruhi oleh inteligensi anak. Skor kecerdasan intelektual yang tidak menetap pada usia tertentu dapat berubah karena faktor genetik, gizi, dan lingkungan. Tujuan penelitian ini adalah mengetahui hubungan kadar hemoglobin dengan kecerdasan intelektual anak. Penelitian observasional dengan desain potong lintang ini dilakukan pada populasi siswa kelas VI Sekolah Dasar Negeri Giwangan Yogyakarta, tahun 2013. Penarikan sampel dilakukan dengan metode simple random sampling terhadap 37 sampel siswa. Instrumen untuk mengukur kecerdasan intelektual dengan Cultural Fair Intelligence Quotient Test yang dirancang untuk meminimalkan pengaruh kultural dengan memperhatikan prosedur evaluasi, instruksi, konten isi, dan respons peserta. Tes dilakukan oleh Biro Psikologi Universitas Ahmad Dahlan Yogyakarta, kadar hemoglobin diukur menggunakan Portable Hemoglobin Digital Analyzer Easy Touch secara digital.Variabel luar indeks massa tubuh diukur langsung menggunakan parameter tinggi badan dan berat badan. Analisis menggunakan uji regresi linier. Hasil penelitian menunjukkan indeks massa tubuh tidak berhubungan dengan kecerdasan intelektual (nilai p = 0,052. Anemia berhubungan cukup dengan kecerdasan anak (r = 0,491 dan berpola positif, semakin tinggi kadar hemoglobin semakin tinggi kecerdasan intelektual anak. Nilai koefisien determinasi 0,241 menerangkan bahwa 24,1% variasi anemia cukup baik untuk menjelaskan variabel kecerdasan intelektual. Ada hubungan antara kadar hemoglobin dengan kecerdasan intelektual (nilai p = 0,002. Quality of human resources is influenced by the child’s intelligent. Intelligence Quotient (IQ score will not settle at a certain age and can change due to genetic factors, nutrition, and the environment. The objective is known relationship of anemia with IQ to child. Method of observational study with cross sectional design. Population are students of class VI elementary school of Giwangan Yogyakarta in

  19. Use of electronic sales data to tailor nutrition education resources for an ethnically diverse population.

    Eyles, H; Rodgers, A; Ni Mhurchu, C

    2010-02-01

    Nutrition education may be most effective when personally tailored. Individualised electronic supermarket sales data offer opportunities to tailor nutrition education using shopper's usual food purchases. The present study aimed to use individualised electronic supermarket sales data to tailor nutrition resources for an ethnically diverse population in a large supermarket intervention trial in New Zealand. Culturally appropriate nutrition education resources (i.e. messages and shopping lists) were developed with the target population (through two sets of focus groups) and ethnic researchers. A nutrient database of supermarket products was developed using retrospective sales data and linked to participant sales to allow tailoring by usual food purchases. Modified Heart Foundation Tick criteria were used to identify 'healthier' products in the database suitable for promotion in the resources. Rules were developed to create a monthly report listing the tailored and culturally targeted messages to be sent to each participant, and to produce automated, tailored shopping lists. Culturally targeted nutrition messages (n = 864) and shopping lists (n = 3 formats) were developed. The food and nutrient database (n = 3000 top-selling products) was created using 12 months of retrospective sales data, and comprised 60%'healthier' products. Three months of baseline sales data were used to determine usual food purchases. Tailored resources were successfully mailed to 123 Māori, 52 Pacific and 346 non-Māori non-Pacific participants over the 6-month trial intervention period. Electronic supermarket sales data can be used to tailor nutrition education resources for a large number of ethnically diverse supermarket shoppers.

  20. REVIEW OF MOODLE PLUGINS FOR DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES FROM LANGUAGE DISCIPLINES

    Anton M. Avramchuk

    2015-09-01

    Full Text Available Today the problem of designing multimedia electronic educational resources from language disciplines in Moodle is very important. This system has a lot of different, powerful resources, plugins to facilitate the learning of students with language disciplines. This article presents an overview and comparative analysis of the five Moodle plugins for designing multimedia electronic educational resources from language disciplines. There have been considered their key features and functionality in order to choose the best for studying language disciplines in the Moodle. Plugins are compared by a group of experts according to the criteria: efficiency, functionality and easy use. For a comparative analysis of the plugins it is used the analytic hierarchy process.

  1. Effects of the Use of Electronic Human Resource Management (EHRM Within Human Resource Management (HRM Functions at Universities

    Chux Gervase Iwu

    2016-09-01

    Full Text Available This study set out to examine the effect of e-hrm systems in assisting human resource practitioners to execute their duties and responsibilities. In comparison to developed economies of the world, information technology adoption in sub-Saharan Africa has not been without certain glitches. Some of the factors that are responsible for these include poor need identification, sustainable funding, and insufficient skills. Besides these factors, there is also the issue of change management and users sticking to what they already know. Although, the above factors seem negative, there is strong evidence that information systems such as electronic human resource management present benefits to an organization. To achieve this, a dual research approach was utilized. Literature assisted immensely in both the development of the conceptual framework upon which the study hinged as well as in the development of the questionnaire items. The study also made use of an interview checklist to guide the participants. The findings reveal a mix of responses that indicate that while there are gains in adopting e-hrm systems, it is wiser to consider supporting resources as well as articulate the needs of the university better before any investment is made.

  2. The Electron Microscopy Outreach Program: A Web-based resource for research and education.

    Sosinsky, G E; Baker, T S; Hand, G; Ellisman, M H

    1999-01-01

    We have developed a centralized World Wide Web (WWW)-based environment that serves as a resource of software tools and expertise for biological electron microscopy. A major focus is molecular electron microscopy, but the site also includes information and links on structural biology at all levels of resolution. This site serves to help integrate or link structural biology techniques in accordance with user needs. The WWW site, called the Electron Microscopy (EM) Outreach Program (URL: http://emoutreach.sdsc.edu), provides scientists with computational and educational tools for their research and edification. In particular, we have set up a centralized resource containing course notes, references, and links to image analysis and three-dimensional reconstruction software for investigators wanting to learn about EM techniques either within or outside of their fields of expertise. Copyright 1999 Academic Press.

  3. Two-photon excited fluorescence emission from hemoglobin

    Sun, Qiqi; Zeng, Yan; Zhang, Wei; Zheng, Wei; Luo, Yi; Qu, Jianan Y.

    2015-03-01

    Hemoglobin, one of the most important proteins in blood, is responsible for oxygen transportation in almost all vertebrates. Recently, we discovered two-photon excited hemoglobin fluorescence and achieved label-free microvascular imaging based on the hemoglobin fluorescence. However, the mechanism of its fluorescence emission still remains unknown. In this work, we studied the two-photon excited fluorescence properties of the hemoglobin subunits, heme/hemin (iron (II)/(III) protoporphyrin IX) and globin. We first studied the properties of heme and the similar spectral and temporal characteristics of heme and hemoglobin fluorescence provide strong evidence that heme is the fluorophore in hemoglobin. Then we studied the fluorescence properties of hemin, globin and methemoglobin, and found that the hemin may have the main effect on the methemoglobin fluorescence and that globin has tryptophan fluorescence like other proteins. Finally, since heme is a centrosymmetric molecule, that the Soret band fluorescence of heme and hemoglobin was not observed in the single photon process in the previous study may be due to the parity selection rule. The discovery of heme two-photon excited fluorescence may open a new window for heme biology research, since heme as a cofactor of hemoprotein has many functions, including chemical catalysis, electron transfer and diatomic gases transportation.

  4. Identifying and evaluating electronic learning resources for use in adult-gerontology nurse practitioner education.

    Thompson, Hilaire J; Belza, Basia; Baker, Margaret; Christianson, Phyllis; Doorenbos, Ardith; Nguyen, Huong

    2014-01-01

    Enhancing existing curricula to meet newly published adult-gerontology advanced practice registered nurse (APRN) competencies in an efficient manner presents a challenge to nurse educators. Incorporating shared, published electronic learning resources (ELRs) in existing or new courses may be appropriate in order to assist students in achieving competencies. The purposes of this project were to (a) identify relevant available ELR for use in enhancing geriatric APRN education and (b) to evaluate the educational utility of identified ELRs based on established criteria. A multilevel search strategy was used. Two independent team members reviewed identified ELR against established criteria to ensure utility. Only resources meeting all criteria were retained. Resources were found for each of the competency areas and included formats such as podcasts, Web casts, case studies, and teaching videos. In many cases, resources were identified using supplemental strategies and not through traditional search or search of existing geriatric repositories. Resources identified have been useful to advanced practice educators in improving lecture and seminar content in a particular topic area and providing students and preceptors with additional self-learning resources. Addressing sustainability within geriatric APRN education is critical for sharing of best practices among educators and for sustainability of teaching and related resources. © 2014.

  5. USE OF ELECTRONIC EDUCATIONAL RESOURCES WHEN TRAINING IN WORK WITH SPREADSHEETS

    Х А Гербеков

    2017-12-01

    Full Text Available Today the tools for maintaining training courses based on opportunities of information and communication technologies are developed. Practically in all directions of preparation and on all subject matters electronic textbook and self-instruction manuals are created. Nevertheless the industry of computer educational and methodical materials actively develops and gets more and more areas of development and introduction. In this regard more and more urgent is a problem of development of the electronic educational resources adequate to modern educational requirements. Creation and the organization of training courses with use of electronic educational resources in particular on the basis of Internet technologies remains a difficult methodical task.In article the questions connected with development of electronic educational resources for use when studying the substantial line “Information technologies” of a school course of informatics in particular for studying of spreadsheets are considered. Also the analysis of maintenance of a school course and the unified state examination from the point of view of representation of task in him corresponding to the substantial line of studying “Information technologies” on mastering technology of information processing in spreadsheets and the methods of visualization given by means of charts and schedules is carried out.

  6. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    Ramli, Rindra M.

    2017-01-01

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables

  7. Non-invasive hemoglobin monitoring.

    Joseph, Bellal; Haider, Ansab; Rhee, Peter

    2016-09-01

    Technology has transformed the practice of medicine and surgery in particular over the last several decades. This change in practice has allowed diagnostic and therapeutic tests to be performed less invasively. Hemoglobin monitoring remains one of the most commonly performed diagnostic tests in the United States. Recently, non-invasive hemoglobin monitoring technology has gained popularity. The aim of this article is to review the principles of how this technology works, pros and cons, and the implications of non-invasive hemoglobin technology particularly in trauma surgery. Copyright © 2015 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  8. Availability, Level of Use and Constraints to Use of Electronic Resources by Law Lecturers in Public Universities in Nigeria

    Amusa, Oyintola Isiaka; Atinmo, Morayo

    2016-01-01

    (Purpose) This study surveyed the level of availability, use and constraints to use of electronic resources among law lecturers in Nigeria. (Methodology) Five hundred and fifty-two law lecturers were surveyed and four hundred and forty-two responded. (Results) Data analysis revealed that the level of availability of electronic resources for the…

  9. GUIDELINES FOR EVALUATION OF PSYCHOLOGICAL AND PEDAGOGICAL QUALITY CHARACTERISTICS OF ELECTRONIC EDUCATIONAL RESOURCES

    Galina P. Lavrentieva

    2014-05-01

    Full Text Available The article highlights the causes of insufficient effective use of electronic learning resources and sets out the guidelines on ways to solve the aforementioned problems. The set of didactic, methodical, psychological, pedagogical, design and ergonomic quality requirements is considered for evaluation, selection and application of information and communication technologies in the educational process. The most appropriate mechanisms for the ICT introduction into the learning process are disclosed as it should meet the specific learning needs of the student and the objectives of the educational process. The guidance for psycho-educational assessment of quality of electronic educational resources is provided. It is argued that the effectiveness of the ICT use is to be improved by means of quality evaluation mechanisms involved into the educational process.

  10. Nonlinear photoacoustic spectroscopy of hemoglobin.

    Danielli, Amos; Maslov, Konstantin; Favazza, Christopher P; Xia, Jun; Wang, Lihong V

    2015-05-18

    As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies of the nonlinear PA spectrum are found to be significantly greater in oxygenated hemoglobin than in deoxygenated hemoglobin. These effects are further influenced by the hemoglobin concentration. These nonlinear phenomena provide insights into applications of photoacoustics, such as measurements of average inter-molecular distances on a nm scale or with a tuned selection of wavelengths, a more accurate quantitative PA tomography.

  11. Nonlinear photoacoustic spectroscopy of hemoglobin

    Danielli, Amos; Maslov, Konstantin; Favazza, Christopher P.; Xia, Jun; Wang, Lihong V.

    2015-01-01

    As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies of the nonlinear PA spectrum are found to be significantly greater in oxygenated hemoglobin than in deoxygenated hemoglobin. These effects are further influenced by the hemoglobin concentration. These nonlinear phenomena provide insights into applications of photoacoustics, such as measurements of average inter-molecular distances on a nm scale or with a tuned selection of wavelengths, a more accurate quantitative PA tomography

  12. Nonlinear photoacoustic spectroscopy of hemoglobin

    Danielli, Amos; Maslov, Konstantin; Favazza, Christopher P.; Xia, Jun; Wang, Lihong V., E-mail: LHWANG@WUSTL.EDU [Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, St. Louis, Missouri 63130 (United States)

    2015-05-18

    As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies of the nonlinear PA spectrum are found to be significantly greater in oxygenated hemoglobin than in deoxygenated hemoglobin. These effects are further influenced by the hemoglobin concentration. These nonlinear phenomena provide insights into applications of photoacoustics, such as measurements of average inter-molecular distances on a nm scale or with a tuned selection of wavelengths, a more accurate quantitative PA tomography.

  13. Model of e-learning with electronic educational resources of new generation

    A. V. Loban; D. A. Lovtsov

    2017-01-01

    Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with elec...

  14. A systematic review of portable electronic technology for health education in resource-limited settings.

    McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C

    2017-08-01

    The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent

  15. Hemoglobin C, S-C, and E Diseases

    ... quickly than others, resulting in chronic anemia. Hemoglobin C disease Hemoglobin C disease occurs mostly in blacks. ... a common complication of hemoglobin C disease. Hemoglobin S-C disease Hemoglobin S-C disease occurs in people who ...

  16. Hemichrome formation during hemoglobin Zurich denaturation

    Zago, M.A.; Costa, F.F.; Botura, C.; Baffa, O.

    1988-01-01

    Electron paramagnetic resonance (EPR)spectrum of hemoglobin Zurich, after oxidation, storage and heating, showed several absorption derives in the high field region (g ≅ 2) which are indicative of hemichrome formation. Characteristic visible spectra of hemichromes were observed for oxidized Hb Zurich and for its spontaneous precipitate. The proportional increase of EPR signals at g ≅ 2 and decrease at g = 6.37, the constant ratio of absorbance at 540 nm to 280 nm during heating, and the similarity of this ratio for spontaneously precipitated HbA and for Hb Zurich indicate that heme is not lost during the first steps of Hb Zurich denaturation. (author) [pt

  17. Model of e-learning with electronic educational resources of new generation

    A. V. Loban

    2017-01-01

    Full Text Available Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with electronic educational resource of new generation is developed, conditionally decomposed into three basic components: the formalization model of the course in the form of the thesaurusclassifier (“Author of e-resource”, the model of learning as management (“Coordination. Consultation. Control”, the learning model with the thesaurus-classifier (“Student”. Model “Author of e-resource” allows the student to achieve completeness, high degree of didactic elaboration and structuring of the studied material in triples of variants: modules of education information, practical task and control tasks; the result of the student’s (author’s of e-resource activity is the thesaurus-classifier. Model of learning as management is based on the principle of personal orientation of learning in computer environment and determines the logic of interaction between the lecturer and the student when determining the triple of variants individually for each student; organization of a dialogue between the lecturer and the student for consulting purposes; personal control of the student’s success (report generation and iterative search for the concept of the class assignment in the thesaurus-classifier before acquiring the required level of training. Model “Student” makes it possible to concretize the learning tasks in relation to the personality of the student and to the training level achieved; the assumption of the lecturer about the level of training of a

  18. Review of material recovery from used electric and electronic equipment-alternative options for resource conservation.

    Friege, Henning

    2012-09-01

    For waste from electric and electronic equipment, the WEEE Directive stipulates the separate collection of electric and electronic waste. As to new electric and electronic devices, the Restriction of Hazardous Substances (RoHS) Directive bans the use of certain chemicals dangerous for man and environment. From the implementation of the WEEE directive, many unsolved problems have been documented: poor collection success, emission of dangerous substances during collection and recycling, irretrievable loss of valuable metals among others. As to RoHS, data from the literature show a satisfying success. The problems identified in the process can be reduced to some basic dilemmas at the borders between waste management, product policy and chemical safety. The objectives of the WEEE Directive and the specific targets for use and recycling of appliances are not consistent. There is no focus on scarce resources. Extended producer responsibility is not sufficient to guarantee sustainable waste management. Waste management reaches its limits due to problems of implementation but also due to physical laws. A holistic approach is necessary looking at all branch points and sinks in the stream of used products and waste from electric and electronic equipment. This may be done with respect to the general rules for sustainable management of material streams covering the three dimensions of sustainable policy. The relationships between the players in the field of electric and electronic devices have to be taken into account. Most of the problems identified in the implementation process will not be solved by the current amendment of the WEEE Directive.

  19. [Use of internet and electronic resources among Spanish intensivist physicians. First national survey].

    Gómez-Tello, V; Latour-Pérez, J; Añón Elizalde, J M; Palencia-Herrejón, E; Díaz-Alersi, R; De Lucas-García, N

    2006-01-01

    Estimate knowledge and use habits of different electronic resources in a sample of Spanish intensivists: Internet, E-mail, distribution lists, and use of portable electronic devices. Self-applied questionnaire. A 50-question questionnaire was distributed among Spanish intensivists through the hospital marketing delegates of a pharmaceutical company and of electronic forums. A total of 682 questionnaires were analyzed (participation: 74%). Ninety six percent of those surveyed used Internet individually: 67% admitted training gap. Internet was the second source of clinical consultations most used (61%), slightly behind consultation to colleagues (65%). The pages consulted most were bibliographic databases (65%) and electronic professional journals (63%), with limited use of Evidence Based Medicine pages (19%). Ninety percent of those surveyed used e-mail regularly in the practice of their profession, although 25% admitted that were not aware of its possibilities. The use of E-mail decreased significantly with increase in age. A total of 62% of the intensivists used distribution lists. Of the rest, 42% were not aware of its existence and 32% admitted they had insufficient training to handle them. Twenty percent of those surveyed had portable electronic devices and 64% considered it useful, basically due to its rapid consultation at bedside. Female gender was a negative predictive factor of its use (OR 0.35; 95% CI 0.2-0.63; p=0.0002). A large majority of the Spanish intensivists use Internet and E-mail. E-mail lists and use of portable devices are still underused resources. There are important gaps in training and infrequent use of essential pages. There are specific groups that require directed educational policies.

  20. The Synthesis of the Hierarchical Structure of Information Resources for Management of Electronic Commerce Entities

    Krutova Anzhelika S.

    2017-06-01

    Full Text Available The aim of the article is to develop the theoretical bases for the classification and coding of economic information and the scientific justification of the content of information resources of an electronic commerce enterprise. The essence of information resources for management of electronic business entities is investigated. It is proved that the organization of accounting in e-commerce systems is advisable to be built on the basis of two circuits: accounting for financial flows and accounting associated with transformation of business factors in products and services as a result of production activities. There presented a sequence of accounting organization that allows to combine the both circuits in a single information system, which provides a possibility for the integrated replenishment and distributed simultaneous use of the e-commerce system by all groups of users. It is proved that the guarantee of efficient activity of the information management system of electronic commerce entities is a proper systematization of the aggregate of information resources on economic facts and operations of an enterprise in accordance with the management tasks by building the hierarchy of accounting nomenclatures. It is suggested to understand nomenclature as an objective, primary information aggregate concerning a certain fact of the economic activity of an enterprise, which is characterized by minimum requisites, is entered into the database of the information system and is to be reflected in the accounting system. It is proposed to build a database of e-commerce systems as a part of directories (constants, personnel, goods / products, suppliers, buyers and the hierarchy of accounting nomenclatures. The package of documents regulating the organization of accounting at an enterprise should include: the provision on the accounting services, the order on the accounting policy, the job descriptions, the schedules of information exchange, the report card and

  1. Hemoglobin affinity in Andean rodents

    HRVOJ OSTOJIC

    2002-01-01

    Full Text Available Blood hemoglobin oxygen affinity (P50 was measured in three Andean species and in the laboratory rat (control, all raised near sea level. Chinchilla lanigera (Molina, 1792 has an altitudinal habitat range from low Andean slopes up to 3000 m., while Chinchilla brevicaudata (Waterhouse, 1848 has an altitudinal range from 3000 to 5000 m. The laboratory type guinea pig, wild type guinea pig (Cavia porcellus, (Waterhouse, 1748, and laboratory rat (Rattus norvegicus were also raised at sea level. The Andean species had high hemoglobin oxygen affinities (low P50 compared with the rat. Chinchilla brevicaudata had a higher affinity than Chinchilla lanigera. The wild type guinea pig had a higher affinity than the laboratory type. As has been shown in other species, this is another example of an inverse correlation between the altitude level and the P50 values. This is the first hemoglobin oxygen affinity study in Chinchilla brevicaudata.

  2. ELECTRONIC EDUCATIONAL RESOURCES FOR ONLINE SUPPORT OF MODERN CHEMISTRY CLASSES IN SPECIALIZED SCHOOL

    Maria D. Tukalo

    2013-09-01

    Full Text Available This article contains material of some modern electronic educational resources that can be used via the Internet to support the modern chemistry classes in specialized school. It was drawn attention to the educational chemical experiments as means of knowledge; simulated key motivational characteristics to enhance students interest for learning subjects, their cognitive and practical activity in the formation of self-reliance and self-creative; commented forecasts for creating of conditions to enhance the creative potential of students in a modern learning environment.

  3. Hemoglobin Wayne Trait with Incidental Polycythemia.

    Ambelil, Manju; Nguyen, Nghia; Dasgupta, Amitava; Risin, Semyon; Wahed, Amer

    2017-01-01

    Hemoglobinopathies, caused by mutations in the globin genes, are one of the most common inherited disorders. Many of the hemoglobin variants can be identified by hemoglobin analysis using conventional electrophoresis and high performance liquid chromatography; however hemoglobin DNA analysis may be necessary in other cases for confirmation. Here, we report a case of a rare alpha chain hemoglobin variant, hemoglobin Wayne, in a 47-year-old man who presented with secondary polycythemia. Capillary zone electrophoresis and high performance liquid chromatography revealed a significant amount of a hemoglobin variant, which was further confirmed by hemoglobin DNA sequencing as hemoglobin Wayne. Since the patient was not homozygous for hemoglobin Wayne, which is associated with secondary polycythemia, the laboratory diagnosis in this case was critical in ruling out hemoglobinopathy as the etiology of his polycythemia. © 2017 by the Association of Clinical Scientists, Inc.

  4. Hemoglobin and heme scavenger receptors

    Nielsen, Marianne Jensby; Møller, Holger Jon; Moestrup, Søren Kragh

    2010-01-01

    Heme, the functional group of hemoglobin, myoglobin, and other hemoproteins, is a highly toxic substance when it appears in the extracellular milieu. To circumvent potential harmful effects of heme from hemoproteins released during physiological or pathological cell damage (such as hemolysis...... and rhabdomyolysis), specific high capacity scavenging systems have evolved in the mammalian organism. Two major systems, which essentially function in a similar way by means of a circulating latent plasma carrier protein that upon ligand binding is recognized by a receptor, are represented by a) the hemoglobin...

  5. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    Anton M. Avramchuk

    2017-10-01

    Full Text Available The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system should be assessed. Developed a model for the development of the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system, which is based on the main scientific approaches, used in adult education, and consists of five blocks: target, informative, technological, diagnostic and effective.

  6. A preliminary categorization of end-of-life electrical and electronic equipment as secondary metal resources

    Oguchi, Masahiro; Murakami, Shinsuke; Sakanakura, Hirofumi; Kida, Akiko; Kameya, Takashi

    2011-01-01

    Highlights: → End-of-life electrical and electronic equipment (EEE) as secondary metal resources. → The content and the total amount of metals in specific equipment are both important. → We categorized 21 EEE types from contents and total amounts of various metals. → Important equipment types as secondary resources were listed for each metal kind. → Collectability and possible collection systems of various EEE types were discussed. - Abstract: End-of-life electrical and electronic equipment (EEE) has recently received attention as a secondary source of metals. This study examined characteristics of end-of-life EEE as secondary metal resources to consider efficient collection and metal recovery systems according to the specific metals and types of EEE. We constructed an analogy between natural resource development and metal recovery from end-of-life EEE and found that metal content and total annual amount of metal contained in each type of end-of-life EEE should be considered in secondary resource development, as well as the collectability of the end-of-life products. We then categorized 21 EEE types into five groups and discussed their potential as secondary metal resources. Refrigerators, washing machines, air conditioners, and CRT TVs were evaluated as the most important sources of common metals, and personal computers, mobile phones, and video games were evaluated as the most important sources of precious metals. Several types of small digital equipment were also identified as important sources of precious metals; however, mid-size information and communication technology (ICT) equipment (e.g., printers and fax machines) and audio/video equipment were shown to be more important as a source of a variety of less common metals. The physical collectability of each type of EEE was roughly characterized by unit size and number of end-of-life products generated annually. Current collection systems in Japan were examined and potentially appropriate collection

  7. Open-Source Electronic Health Record Systems for Low-Resource Settings: Systematic Review.

    Syzdykova, Assel; Malta, André; Zolfo, Maria; Diro, Ermias; Oliveira, José Luis

    2017-11-13

    Despite the great impact of information and communication technologies on clinical practice and on the quality of health services, this trend has been almost exclusive to developed countries, whereas countries with poor resources suffer from many economic and social issues that have hindered the real benefits of electronic health (eHealth) tools. As a component of eHealth systems, electronic health records (EHRs) play a fundamental role in patient management and effective medical care services. Thus, the adoption of EHRs in regions with a lack of infrastructure, untrained staff, and ill-equipped health care providers is an important task. However, the main barrier to adopting EHR software in low- and middle-income countries is the cost of its purchase and maintenance, which highlights the open-source approach as a good solution for these underserved areas. The aim of this study was to conduct a systematic review of open-source EHR systems based on the requirements and limitations of low-resource settings. First, we reviewed existing literature on the comparison of available open-source solutions. In close collaboration with the University of Gondar Hospital, Ethiopia, we identified common limitations in poor resource environments and also the main requirements that EHRs should support. Then, we extensively evaluated the current open-source EHR solutions, discussing their strengths and weaknesses, and their appropriateness to fulfill a predefined set of features relevant for low-resource settings. The evaluation methodology allowed assessment of several key aspects of available solutions that are as follows: (1) integrated applications, (2) configurable reports, (3) custom reports, (4) custom forms, (5) interoperability, (6) coding systems, (7) authentication methods, (8) patient portal, (9) access control model, (10) cryptographic features, (11) flexible data model, (12) offline support, (13) native client, (14) Web client,(15) other clients, (16) code

  8. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    Anton M. Avramchuk

    2017-01-01

    The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing ...

  9. Determining the level of awareness of the physicians in using the variety of electronic information resources and the effecting factors.

    Papi, Ahmad; Ghazavi, Roghayeh; Moradi, Salimeh

    2015-01-01

    Understanding of the medical society's from the types of information resources for quick and easy access to information is an imperative task in medical researches and management of the treatment. The present study was aimed to determine the level of awareness of the physicians in using various electronic information resources and the factors affecting it. This study was a descriptive survey. The data collection tool was a researcher-made questionnaire. The study population included all the physicians and specialty physicians of the teaching hospitals affiliated to Isfahan University of Medical Sciences and numbered 350. The sample size based on Morgan's formula was set at 180. The content validity of the tool was confirmed by the library and information professionals and the reliability was 95%. Descriptive statistics were used including the SPSS software version 19. On reviewing the need of the physicians to obtain the information on several occasions, the need for information in conducting the researches was reported by the maximum number of physicians (91.9%) and the usage of information resources, especially the electronic resources, formed 65.4% as the highest rate with regard to meeting the information needs of the physicians. Among the electronic information databases, the maximum awareness was related to Medline with 86.5%. Among the various electronic information resources, the highest awareness (43.3%) was related to the E-journals. The highest usage (36%) was also from the same source. The studied physicians considered the most effective deterrent in the use of electronic information resources as being too busy and lack of time. Despite the importance of electronic information resources for the physician's community, there was no comprehensive knowledge of these resources. This can lead to less usage of these resources. Therefore, careful planning is necessary in the hospital libraries in order to introduce the facilities and full capabilities of the

  10. Success criteria for electronic medical record implementations in low-resource settings: a systematic review.

    Fritz, Fleur; Tilahun, Binyam; Dugas, Martin

    2015-03-01

    Electronic medical record (EMR) systems have the potential of supporting clinical work by providing the right information at the right time to the right people and thus make efficient use of resources. This is especially important in low-resource settings where reliable data are also needed to support public health and local supporting organizations. In this systematic literature review, our objectives are to identify and collect literature about success criteria of EMR implementations in low-resource settings and to summarize them into recommendations. Our search strategy relied on PubMed queries and manual bibliography reviews. Studies were included if EMR implementations in low-resource settings were described. The extracted success criteria and measurements were summarized into 7 categories: ethical, financial, functionality, organizational, political, technical, and training. We collected 381 success criteria with 229 measurements from 47 articles out of 223 articles. Most papers were evaluations or lessons learned from African countries, published from 1999 to 2013. Almost half of the EMR systems served a specific disease area like human immunodeficiency virus (HIV). The majority of criteria that were reported dealt with the functionality, followed by organizational issues, and technical infrastructures. Sufficient training and skilled personnel were mentioned in roughly 10%. Political, ethical, and financial considerations did not play a predominant role. More evaluations based on reliable frameworks are needed. Highly reliable data handling methods, human resources and effective project management, as well as technical architecture and infrastructure are all key factors for successful EMR implementation. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Impact of Knowledge Resources Linked to an Electronic Health Record on Frequency of Unnecessary Tests and Treatments

    Goodman, Kenneth; Grad, Roland; Pluye, Pierre; Nowacki, Amy; Hickner, John

    2012-01-01

    Introduction: Electronic knowledge resources have the potential to rapidly provide answers to clinicians' questions. We sought to determine clinicians' reasons for searching these resources, the rate of finding relevant information, and the perceived clinical impact of the information they retrieved. Methods: We asked general internists, family…

  12. Resource conservation approached with an appropriate collection and upgrade-remanufacturing for used electronic products.

    Zlamparet, Gabriel I; Tan, Quanyin; Stevels, A B; Li, Jinhui

    2018-03-01

    This comparative research represents an example for a better conservation of resources by reducing the amount of waste (kg) and providing it more value under the umbrella of remanufacturing. The three discussed cases will expose three issues already addressed separately in the literature. The generation of waste electrical and electronic equipment (WEEE) interacts with the environmental depletion. In this article, we gave the examples of addressed issues under the concept of remanufacturing. Online collection opportunity eliminating classical collection, a business to business (B2B) implementation for remanufactured servers and medical devices. The material reuse (recycling), component sustainability, reuse (part harvesting), product reuse (after repair/remanufacturing) indicates the recovery potential using remanufacturing tool for a better conservation of resources adding more value to the products. Our findings can provide an overview of new system organization for the general collection, market potential and the technological advantages using remanufacturing instead of recycling of WEEE or used electrical and electronic equipment. Copyright © 2017. Published by Elsevier Ltd.

  13. A microfluidic approach for hemoglobin detection in whole blood

    Taparia, Nikita; Platten, Kimsey C.; Anderson, Kristin B.; Sniadecki, Nathan J.

    2017-10-01

    Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  14. Electronic theses and dissertations: a review of this valuable resource for nurse scholars worldwide.

    Goodfellow, L M

    2009-06-01

    A worldwide repository of electronic theses and dissertations (ETDs) could provide worldwide access to the most up-to-date research generated by masters and doctoral students. Until that international repository is established, it is possible to access some of these valuable knowledge resources. ETDs provide a technologically advanced medium with endless multimedia capabilities that far exceed the print and bound copies of theses and dissertations housed traditionally in individual university libraries. CURRENT USE: A growing trend exists for universities worldwide to require graduate students to submit theses or dissertations as electronic documents. However, nurse scholars underutilize ETDs, as evidenced by perusing bibliographic citation lists in many of the research journals. ETDs can be searched for and retrieved through several digital resources such as the Networked Digital Library of Theses and Dissertations (http://www.ndltd.org), ProQuest Dissertations and Theses (http://www.umi.com), the Australasian Digital Theses Program (http://adt.caul.edu.au/) and through individual university web sites and online catalogues. An international repository of ETDs benefits the community of nurse scholars in many ways. The ability to access recent graduate students' research electronically from anywhere in the world is advantageous. For scholars residing in developing countries, access to these ETDs may prove to be even more valuable. In some cases, ETDs are not available for worldwide access and can only be accessed through the university library from which the student graduated. Public access to university library ETD collections is not always permitted. Nurse scholars from both developing and developed countries could benefit from ETDs.

  15. Hemoglobin of mice with radiation-induced mutations at the hemoglobin loci

    Popp, R.A.; Stratton, L.P.; Hawley, D.K.; Effron, K.

    1979-01-01

    Chemical analyses were done on the abnormal hemoglobins of the five (101 x SEC)F 1 offspring of X- irradiated adult SEC mice to determine which hemoglobin genes were expressed in each hemoglobin variant. Three offspring of irradiated SEC males did not express either of the two kinds of α-chains normally found in all SEC mice. The deficient α-chain synthesis caused these mice to exhibit an α-thalassemia similar to human α-thalassemia. Scanning electron microscopy was used to show that many erythrocytes of mice with α-thalassemia have bizarre shapes; e.g. many erythrocytes appeared flattened or had thorny projections (acanthocytes). One mutant with a tandem duplication of a segment of chromosome 7 (site of locus determining β-chain structure) produced twice as much SEC as 101 β-chain polypeptides. One mutant that probably arose by non-disjunction of chromosome 7's in its unirradiated 101 mother and loss of chromosome 7 from the gamete of its irradiated SEC father did not express the SEC β-chain gene. (author)

  16. Hemoglobin of mice with radiation-induced mutations at the hemoglobin loci

    Popp, R A; Stratton, L P; Hawley, D K; Effron, K [Oak Ridge National Lab., TN (USA)

    1979-01-15

    Chemical analyses were done on the abnormal hemoglobins of the five (101 x SEC)F/sub 1/ offspring of X- irradiated adult SEC mice to determine which hemoglobin genes were expressed in each hemoglobin variant. Three offspring of irradiated SEC males did not express either of the two kinds of ..cap alpha..-chains normally found in all SEC mice. The deficient ..cap alpha..-chain synthesis caused these mice to exhibit an ..cap alpha..-thalassemia similar to human ..cap alpha..-thalassemia. Scanning electron microscopy was used to show that many erythrocytes of mice with ..cap alpha..-thalassemia have bizarre shapes; e.g. many erythrocytes appeared flattened or had thorny projections (acanthocytes). One mutant with a tandem duplication of a segment of chromosome 7 (site of locus determining ..beta..-chain structure) produced twice as much SEC as 101 ..beta..-chain polypeptides. One mutant that probably arose by non-disjunction of chromosome 7's in its unirradiated 101 mother and loss of chromosome 7 from the gamete of its irradiated SEC father did not express the SEC ..beta..-chain gene.

  17. Direct electrochemistry and electrocatalysis of hemoglobin protein entrapped in graphene and chitosan composite film.

    Xu, Huifeng; Dai, Hong; Chen, Guonan

    2010-04-15

    A novel, biocompatible sensing strategy based on graphene and chitosan composite film for immobilizing the hemoglobin protein was firstly adopted. The direct electron transfer and bioelectrocatalytic activity of hemoglobin after incorporation into the composite film were investigated. A pair of reversible redox waves of hemoglobin was appeared, and hemoglobin could exhibit its bioelectrocatalytic activity toward H(2)O(2) in a long term. Such results indicated that graphene and chitosan composite could be a friendly biocompatible interface for immobilizing biomolecules and keeping their native structure. Furthermore, the appearance of graphene in the composite film could facilitate the electron transfer between matrix and the electroactive center of hemoglobin. Hence, this graphene and chitosan based protocol would be a promising platform for protein immobilization and biosensor preparation. (c) 2010 Elsevier B.V. All rights reserved.

  18. Identification of hemoglobin variants by top-down mass spectrometry using selected diagnostic product ions.

    Coelho Graça, Didia; Hartmer, Ralf; Jabs, Wolfgang; Beris, Photis; Clerici, Lorella; Stoermer, Carsten; Samii, Kaveh; Hochstrasser, Denis; Tsybin, Yury O; Scherl, Alexander; Lescuyer, Pierre

    2015-04-01

    Hemoglobin disorder diagnosis is a complex procedure combining several analytical steps. Due to the lack of specificity of the currently used protein analysis methods, the identification of uncommon hemoglobin variants (proteoforms) can become a hard task to accomplish. The aim of this work was to develop a mass spectrometry-based approach to quickly identify mutated protein sequences within globin chain variants. To reach this goal, a top-down electron transfer dissociation mass spectrometry method was developed for hemoglobin β chain analysis. A diagnostic product ion list was established with a color code strategy allowing to quickly and specifically localize a mutation in the hemoglobin β chain sequence. The method was applied to the analysis of rare hemoglobin β chain variants and an (A)γ-β fusion protein. The results showed that the developed data analysis process allows fast and reliable interpretation of top-down electron transfer dissociation mass spectra by nonexpert users in the clinical area.

  19. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    Ramli, Rindra M.

    2017-05-17

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables and challenges as well as lessons learnt by the Project Team.

  20. Blood Test: Hemoglobin A1C

    ... Why Are Hemoglobin A1c Tests Done? When a child has diabetes, hemoglobin A1c levels are followed to see how well medicines are working. If a child with diabetes has a high hemoglobin A1c level, it may ...

  1. Characteristic emission in glutaraldehyde polymerized hemoglobin

    Ma Li; Wang Xiaojun

    2011-01-01

    Hemoglobin with different modifications has been investigated using spectroscopic techniques. A new emission at around 371 nm has been observed under excitation of 305 nm from glutaraldehyde polymerized human hemoglobin. Intensity and peak position of the emission are dependent on both oxidation state and ligand environment and the emission has been identified from the hemoglobin oligomer.

  2. Electronic tracking of human resource skills and knowledge, just in time training, manageable due diligence

    Kolodziej, M.A. [Quick Test International Inc., (Canada). Canadian Technology Human Resource Board; Baker, O. [KeySpan Energy Canada, Calgary, AB (Canada)

    2001-06-01

    KeySpan Energy Canada is in the process of obtaining recognition of various occupational profiles including pipeline operators, inspectors, and field and plant operators from various certifying organizations. The process of allowing individuals to obtain certification is recognized by Canadian Technology Human Resources Board as a step towards national standards for technologists and technicians. Proven competency is a must for workers in todays oil industry in response to increasingly stringent government safety regulations, environmental concerns and high public scrutiny. Quick Test international Inc. has developed a management tool in collaboration with end users at KeySpan Energy Canada. It is an electronic, Internet based competency tool for tracking personal competencies and maintaining continued competency. Response to the tool has been favourable. 2 refs., 4 figs.

  3. Hemoglobin Test: MedlinePlus Lab Test Information

    ... page: https://medlineplus.gov/labtests/hemoglobintest.html Hemoglobin Test To use the sharing features on this page, please enable JavaScript. What is a Hemoglobin Test? A hemoglobin test measures the levels of hemoglobin ...

  4. Availability, Use and Constraints to Use of Electronic Information Resources by Postgraduates Students at the University of Ibadan

    Dare Samuel Adeleke

    2017-12-01

    Full Text Available Availability, awareness and use of electronic resources provide access to authoritative, reliable, accurate and timely access to information. The use of electronic information resources (EIRs can enable innovation in teaching and increase timeliness in research of postgraduate students which will eventual result into encouragement of the expected research-led enquiry in this digital age. The study adopted a descriptive survey design. Samples of 300 of postgraduate students within seven out 13 Faculties were randomly selected. Data were collected using questionnaire designed to elicit response from respondents and data were analyzed using descriptive statistics methods percentages, mean, and standard deviation. Results indicated that internet was ranked most available and used in the university. Low level of usage of electronic resources, in particular, full texts data bases is linked to a number of constraints: Interrupted power supply was ranked highest among other factors as speed and capacity of computers, retrieval of records with high recall and low precision, retrieving records relevant to information need, lack of knowledge of search techniques to retrieve information effectively, non possession of requisite IT skills and problems accessing the internet. The study recommended that usage of electronic resources be made compulsory, intensifying awareness campaigns concerning the availability, training on use of electronic resources and the problem of power outage be addressed.

  5. Using mobile electronic devices to deliver educational resources in developing countries.

    Mazal, Jonathan Robert; Ludwig, Rebecca

    2015-01-01

    Developing countries have far fewer trained radiography professionals than developed countries, which exacerbates the limited access to imaging services. The lack of trained radiographers reflects, in part, limited availability of radiographer-specific educational resources. Historically, organizations that provided such resources in the developing world faced challenges related to the limited stock of current materials as well as expenses associated with shipping and delivery. Four mobile electronic devices (MEDs) were loaded with educational content (e-books, PDFs, and digital applications) spanning major radiography topics. The MEDs were distributed to 4 imaging departments in Ghana, India, Nepal, and Nigeria based on evidence of need for radiography-specific resources, as revealed by survey responses. A cost comparison of postal delivery vs digital delivery of educational content was performed. The effectiveness of delivering additional content via Wi-Fi transmission also was evaluated. Feedback was solicited on users' experience with the MEDs as a delivery tool for educational content. An initial average per e-book expense of $30.05, which included the cost of the device, was calculated for the MED delivery method compared with $15.56 for postal delivery of printed materials. The cost of the MED delivery method was reduced to an average of $10.05 for subsequent e-book deliveries. Additional content was successfully delivered via Wi-Fi transmission to all recipients during the 3-month follow-up period. Overall user feedback on the experience was positive, and ideas for enhancing the MED-based method were identified. Using MEDs to deliver radiography-specific educational content appears to be more cost effective than postal delivery of printed materials on a long-term basis. MEDs are more efficient for providing updates to educational materials. Customization of content to department needs, and using projector devices could enhance the usefulness of MEDs for

  6. Hemoglobin Function in Stored Blood.

    1974-08-01

    States during 1973. Several advantages over ACA) are important. Blood stored in CPD maintains higher ./ levels of 2,3-DPG (2,3- diphosphoglycerate ) and a...survival and ATP levels in stored blood is explained by the several functions of ATP which are necessary for cell viability. However, ATP levels do...not correlate with oxygen affinity during storage. Levels of 2,3-DPG determine oxygen affinity and thus hemoglobin function. (12,13) When normal levels

  7. The electronic encapsulation of knowledge in hydraulics, hydrology and water resources

    Abbott, Michael B.

    The rapidly developing practice of encapsulating knowledge in electronic media is shown to lead necessarily to the restructuring of the knowledge itself. The consequences of this for hydraulics, hydrology and more general water-resources management are investigated in particular relation to current process-simulation, real-time control and advice-serving systems. The generic properties of the electronic knowledge encapsulator are described, and attention is drawn to the manner in which knowledge 'goes into hiding' through encapsulation. This property is traced in the simple situations of pure mathesis and in the more complex situations of taxinomia using one example each from hydraulics and hydrology. The consequences for systems architectures are explained, pointing to the need for multi-agent architectures for ecological modelling and for more general hydroinformatics systems also. The relevance of these developments is indicated by reference to ongoing projects in which they are currently being realised. In conclusion, some more general epistemological aspects are considered within the same context. As this contribution is so much concerned with the processes of signification and communication, it has been partly shaped by the theory of semiotics, as popularised by Eco ( A Theory of Semiotics, Indiana University, Bloomington, 1977).

  8. Plastics disassembly versus bulk recycling: engineering design for end-of-life electronics resource recovery.

    Rios, Pedro; Stuart, Julie Ann; Grant, Ed

    2003-12-01

    Annual plastic flows through the business and consumer electronics manufacturing supply chain include nearly 3 billion lb of high-value engineering plastics derived from petroleum. The recovery of resource value from this stream presents critical challenges in areas of materials identification and recycling process design that demand new green engineering technologies applied together with life cycle assessment and ecological supply chain analysis to create viable plastics-to-plastics supply cycles. The sustainable recovery of potentially high-value engineering plastics streams requires that recyclers either avoid mixing plastic parts or purify later by separating smaller plastic pieces created in volume reduction (shredding) steps. Identification and separation constitute significant barriers in the plastics-to-plastics recycling value proposition. In the present work, we develop a model that accepts randomly arriving electronic products to study scenarios by which a recycler might identify and separate high-value engineering plastics as well as metals. Using discrete eventsimulation,we compare current mixed plastics recovery with spectrochemical plastic resin identification and subsequent sorting. Our results show that limited disassembly with whole-part identification can produce substantial yields in separated streams of recovered engineering thermoplastics. We find that disassembly with identification does not constitute a bottleneck, but rather, with relatively few workers, can be configured to pull the process and thus decrease maximum staging space requirements.

  9. Oxygen binding to nitric oxide marked hemoglobin

    Louro, S.R.W.; Ribeiro, P.C.; Bemski, G.

    1979-04-01

    Electron spin resonance spectra of organic phosphate free human hemoglobin marked with nitric oxide at the sixth coordination position of one of the four hemes allow to observe the transition from the tense (T) to the relaxed (R) conformation, as a function of parcial oxygen pressure. The spectra are composites of contributions from α sub(T), α sub(R) and β chains spectra, showing the presence of only two conformations: T and R. In the absence of organic phosphates NO binds to α and β chains with the same probability, but in the presence of phosphates NO combines preferentially with α chains. The dissociation of NO proceeds at least an order of magnitude faster in T than in R configuration. (author) [pt

  10. SAGES: a suite of freely-available software tools for electronic disease surveillance in resource-limited settings.

    Sheri L Lewis

    Full Text Available Public health surveillance is undergoing a revolution driven by advances in the field of information technology. Many countries have experienced vast improvements in the collection, ingestion, analysis, visualization, and dissemination of public health data. Resource-limited countries have lagged behind due to challenges in information technology infrastructure, public health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES is a collection of modular, flexible, freely-available software tools for electronic disease surveillance in resource-limited settings. One or more SAGES tools may be used in concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility allows for the development of an inexpensive, customized, and sustainable disease surveillance system. The ability to rapidly assess anomalous disease activity may lead to more efficient use of limited resources and better compliance with World Health Organization International Health Regulations.

  11. Role of Reversible Histidine Coordination in Hydroxylamine Reduction by Plant Hemoglobins (Phytoglobins).

    Athwal, Navjot Singh; Alagurajan, Jagannathan; Andreotti, Amy H; Hargrove, Mark S

    2016-10-18

    Reduction of hydroxylamine to ammonium by phytoglobin, a plant hexacoordinate hemoglobin, is much faster than that of other hexacoordinate hemoglobins or pentacoordinate hemoglobins such as myoglobin, leghemoglobin, and red blood cell hemoglobin. The reason for differences in reactivity is not known but could be intermolecular electron transfer between protein molecules in support of the required two-electron reduction, hydroxylamine binding, or active site architecture favoring the reaction. Experiments were conducted with phytoglobins from rice, tomato, and soybean along with human neuroglobin and soybean leghemoglobin that reveal hydroxylamine binding as the rate-limiting step. For hexacoordinate hemoglobins, binding is limited by the dissociation rate constant for the distal histidine, while leghemoglobin is limited by an intrinsically low affinity for hydroxylamine. When the distal histidine is removed from rice phytoglobin, a hydroxylamine-bound intermediate is formed and the reaction rate is diminished, indicating that the distal histidine imidazole side chain is critical for the reaction, albeit not for electron transfer but rather for direct interaction with the substrate. Together, these results demonstrate that phytoglobins are superior at hydroxylamine reduction because they have distal histidine coordination affinity constants near 1, and facile rate constants for binding and dissociation of the histidine side chain. Hexacoordinate hemoglobins such as neuroglobin are limited by tighter histidine coordination that blocks hydroxylamine binding, and pentacoordinate hemoglobins have intrinsically lower hydroxylamine affinities.

  12. Electronic Human Resources Management (e-HRM Adoption Studies: Past and Future Research

    Winarto Winarto

    2018-05-01

    Full Text Available Electronic human resource management (e-HRM systems become more widely used by profit and non-profit organization. However, the field currently lacks sound theoretical frameworks that can be useful in addressing a key issue concerning the implementation of e-HRM systems, in particular to obtain a better understanding of the factors influencing the adoption of e-HRM systems. The objective of this paper is to provide a foundation towards the development of a theoretical framework for the implementation of e-HRM systems and develop a conceptual model that would reflect the nature of e-HRM systems’ adoption through systematic literature review. Adopting Crossan and Apaydin’s procedure of systematic review, this paper investigated 21 empirical papers of electronics human resources management, then categorized them into 4 characteristics which influence the adoption; System and technology characteristics; Organizational characteristics; User/individual characteristics, and Environmental and contextual characteristics. Finally, the e-HRM adoption research framework is drawn and based on the framework; avenues for future research are discussed.   Bahasa Indonesia Abstrak: Manajemen sumber daya manusia elektronik (selanjutnya disebut dengan e-HRM semakin banyak digunakan oleh organisasi profit dan nonprofit. Namun, bidang dan topik ini belum memiliki kerangka teori yang mapan, yang dapat digunakan untuk menganalisis isu-isu terkait penerapan e-HRM, terutama mengenai faktor-faktor yang mempengaruhi adopsi sistem e-HRM. Tujuan penelitian ini adalah untuk memberikan landasan bagi pengembangan kerangka teoritis untuk implementasi sistem e-HRM dan mengembangkan model konseptual yang akan menggambarkan adopsi sistem e-HRM melalui tinjauan literatur sistematis. Mengadopsi prosedur dan metode Crossan dan Apaydin untuk melakukan telaah literatur secara sistematis, paper ini menyelidiki 21 publikasi empiris manajemen sumber daya manusia elektronik dari 2

  13. PLASMA PROTEIN AND HEMOGLOBIN PRODUCTION

    Robscheit-Robbins, F. S.; Miller, L. L.; Whipple, G. H.

    1947-01-01

    Given healthy dogs fed abundant iron and protein-free or low protein diets with sustained anemia and hypoproteinemia, we can study the capacity of these animals to produce simultaneously new hemoglobin and plasma protein. Reserve stores of blood protein-building materials are measurably depleted and levels of 6 to 8 gm. per cent for hemoglobin and 4 to 5 gm. per cent for plasma protein can be maintained for weeks or months depending upon the intake of food proteins or amino acid mixtures. These dogs are very susceptible to infection and various poisons. Dogs tire of these diets and loss of appetite terminates many experiments. Under these conditions (double depletion) standard growth mixtures of essential amino acids are tested to show the response in blood protein output and urinary nitrogen balance. As a part of each tabulated experiment one of the essential amino acids is deleted from the complete growth mixture to compare such response with that of the whole mixture. Methionine, threonine, phenylalanine, and tryptophane when singly eliminated from the complete amino acid mixture do effect a sharp rise in urinary nitrogen. This loss of urinary nitrogen is corrected when the individual amino acid is replaced in the mixture. Histidine, lysine, and valine have a moderate influence upon urinary nitrogen balance toward nitrogen conservation. Leucine, isoleucine, and arginine have minimal or no effect upon urinary nitrogen balance when these individual amino acids are deleted from the complete growth mixture of amino acids during 3 to 4 week periods. Tryptophane and to a less extent phenylalanine and threonine when returned to the amino acid mixture are associated with a conspicuous preponderance of plasma protein output over the hemoglobin output (Table 4). Arginine, lysine, and histidine when returned to the amino acid mixture are associated with a large preponderance of hemoglobin output. Various amino acid mixtures under these conditions may give a positive

  14. Hemoglobin Labeled by Radioactive Lysine

    Bale, W. F.; Yuile, C. L.; DeLaVergne, L.; Miller, L. L.; Whipple, G. H.

    1949-12-08

    This paper reports on the utilization of tagged epsilon carbon of DL-lysine by a dog both anemic and hypoproteinemic due to repeated bleeding plus a diet low in protein. The experiment extended over period of 234 days, a time sufficient to indicate an erythrocyte life span of at least 115 days based upon the rate of replacement of labeled red cell proteins. The proteins of broken down red cells seem not to be used with any great preference for the synthesis of new hemoglobin.

  15. Determination Of Ph Including Hemoglobin Correction

    Maynard, John D.; Hendee, Shonn P.; Rohrscheib, Mark R.; Nunez, David; Alam, M. Kathleen; Franke, James E.; Kemeny, Gabor J.

    2005-09-13

    Methods and apparatuses of determining the pH of a sample. A method can comprise determining an infrared spectrum of the sample, and determining the hemoglobin concentration of the sample. The hemoglobin concentration and the infrared spectrum can then be used to determine the pH of the sample. In some embodiments, the hemoglobin concentration can be used to select an model relating infrared spectra to pH that is applicable at the determined hemoglobin concentration. In other embodiments, a model relating hemoglobin concentration and infrared spectra to pH can be used. An apparatus according to the present invention can comprise an illumination system, adapted to supply radiation to a sample; a collection system, adapted to collect radiation expressed from the sample responsive to the incident radiation; and an analysis system, adapted to relate information about the incident radiation, the expressed radiation, and the hemoglobin concentration of the sample to pH.

  16. Hemoglobin Variants: Biochemical Properties and Clinical Correlates

    Thom, Christopher S.; Dickson, Claire F.; Gell, David A.; Weiss, Mitchell J.

    2013-01-01

    Diseases affecting hemoglobin synthesis and function are extremely common worldwide. More than 1000 naturally occurring human hemoglobin variants with single amino acid substitutions throughout the molecule have been discovered, mainly through their clinical and/or laboratory manifestations. These variants alter hemoglobin structure and biochemical properties with physiological effects ranging from insignificant to severe. Studies of these mutations in patients and in the laboratory have produced a wealth of information on hemoglobin biochemistry and biology with significant implications for hematology practice. More generally, landmark studies of hemoglobin performed over the past 60 years have established important paradigms for the disciplines of structural biology, genetics, biochemistry, and medicine. Here we review the major classes of hemoglobin variants, emphasizing general concepts and illustrative examples. PMID:23388674

  17. Impact of Electronic Resources and Usage in Academic Libraries in Ghana: Evidence from Koforidua Polytechnic & All Nations University College, Ghana

    Akussah, Maxwell; Asante, Edward; Adu-Sarkodee, Rosemary

    2015-01-01

    The study investigates the relationship between impact of electronic resources and its usage in academic libraries in Ghana: evidence from Koforidua Polytechnic & All Nations University College, Ghana. The study was a quantitative approach using questionnaire to gather data and information. A valid response rate of 58.5% was assumed. SPSS…

  18. Utilization of Electronic Information Resources by Undergraduate Students of University of Ibadan: A Case Study of Social Sciences and Education

    Owolabi, Sola; Idowu, Oluwafemi A.; Okocha, Foluke; Ogundare, Atinuke Omotayo

    2016-01-01

    The study evaluated utilization of electronic information resources by undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan. The study adopted a descriptive survey design with a study population of 1872 undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan, from which a…

  19. Systematic review of electronic surveillance of infectious diseases with emphasis on antimicrobial resistance surveillance in resource-limited settings.

    Rattanaumpawan, Pinyo; Boonyasiri, Adhiratha; Vong, Sirenda; Thamlikitkul, Visanu

    2018-02-01

    Electronic surveillance of infectious diseases involves rapidly collecting, collating, and analyzing vast amounts of data from interrelated multiple databases. Although many developed countries have invested in electronic surveillance for infectious diseases, the system still presents a challenge for resource-limited health care settings. We conducted a systematic review by performing a comprehensive literature search on MEDLINE (January 2000-December 2015) to identify studies relevant to electronic surveillance of infectious diseases. Study characteristics and results were extracted and systematically reviewed by 3 infectious disease physicians. A total of 110 studies were included. Most surveillance systems were developed and implemented in high-income countries; less than one-quarter were conducted in low-or middle-income countries. Information technologies can be used to facilitate the process of obtaining laboratory, clinical, and pharmacologic data for the surveillance of infectious diseases, including antimicrobial resistance (AMR) infections. These novel systems require greater resources; however, we found that using electronic surveillance systems could result in shorter times to detect targeted infectious diseases and improvement of data collection. This study highlights a lack of resources in areas where an effective, rapid surveillance system is most needed. The availability of information technology for the electronic surveillance of infectious diseases, including AMR infections, will facilitate the prevention and containment of such emerging infectious diseases. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. The Use of Electronic Resources by Academic Staff at the University of Ilorin, Nigeria

    Tella, Adeyinka; Orim, Faith; Ibrahim, Dauda Morenikeji; Memudu, Suleiman Ajala

    2018-01-01

    The use of e-resources is now commonplace among academics in tertiary educational institutions the world over. Many academics including those in the universities are exploring the opportunities of e-resources to facilitate teaching and research. As the use of e-resources is increasing particularly among academics at the University of Ilorin,…

  1. A microfluidic approach for hemoglobin detection in whole blood

    Nikita Taparia

    2017-10-01

    Full Text Available Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  2. Modeling antecedents of electronic medical record system implementation success in low-resource setting hospitals.

    Tilahun, Binyam; Fritz, Fleur

    2015-08-01

    With the increasing implementation of Electronic Medical Record Systems (EMR) in developing countries, there is a growing need to identify antecedents of EMR success to measure and predict the level of adoption before costly implementation. However, less evidence is available about EMR success in the context of low-resource setting implementations. Therefore, this study aims to fill this gap by examining the constructs and relationships of the widely used DeLone and MacLean (D&M) information system success model to determine whether it can be applied to measure EMR success in those settings. A quantitative cross sectional study design using self-administered questionnaires was used to collect data from 384 health professionals working in five governmental hospitals in Ethiopia. The hospitals use a comprehensive EMR system since three years. Descriptive and structural equation modeling methods were applied to describe and validate the extent of relationship of constructs and mediating effects. The findings of the structural equation modeling shows that system quality has significant influence on EMR use (β = 0.32, P quality has significant influence on EMR use (β = 0.44, P service quality has strong significant influence on EMR use (β = 0.36, P effect of EMR use on user satisfaction was not significant. Both EMR use and user satisfaction have significant influence on perceived net-benefit (β = 0.31, P mediating factor in the relationship between service quality and EMR use (P effect on perceived net-benefit of health professionals. EMR implementers and managers in developing countries are in urgent need of implementation models to design proper implementation strategies. In this study, the constructs and relationships depicted in the updated D&M model were found to be applicable to assess the success of EMR in low resource settings. Additionally, computer literacy was found to be a mediating factor in EMR use and user satisfaction of

  3. NITRO MUSK BOUND TO CARP HEMOGLOBIN ...

    Nitroaromatic compounds including synthetic nitro musks are important raw materials and intermediates in the synthesis of explosives, dyes, and pesticides, pharmaceutical and personal care-products (PPCPs). The nitro musks such as musk xylene (MX) and musk ketone (MK) are extensively used as fragrance ingredients in PPCPs and other commercial toiletries. Identification and quantification of a bound 4-amino-MX (4-AMX) metabolite as well as a 2- amino-MK (2-AMK) metabolite were carried out by gas chromatography-mass spectrometry' (GC/MS), with selected ion monitoring (SIM) in both the electron ionization (ElMS) and electron capture (EC) negative ion chemical ionization (NICIMS) modes. Detection of 4-AMX and 2-AMK occurred after the cysteine adducts in carp hemoglobin, derived from the nitroso metabolites, were released by alkaline hydrolysis. The released metabolites were extracted into n-hexane. The extract was preconcentrated by evaporation, and analyzed by GC-SIM-MS. A comparison between the El and EC approaches was made. EC NICIMS detected both metabolites whereas only 4-AMX was detected by ElMS. The EC NICIMS approach exhibited fewer matrix responses and provided a lower detection limit. Quantitation in both approaches was based on internal standard and a calibration plot. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water, and ORD in the area of Water Q

  4. Determination of Human Hemoglobin Derivatives.

    Attia, Atef M M; Ibrahim, Fatma A A; Abd El-Latif, Noha A; Aziz, Samir W; Abdelmottaleb Moussa, Sherif A; Elalfy, Mohsen S

    2015-01-01

    The levels of the inactive hemoglobin (Hb) pigments [such as methemoglobin (metHb), carboxyhemoglobin (HbCO) and sulfohemoglobin (SHb)] and the active Hb [in the oxyhemoglobin (oxyHb) form] as well as the blood Hb concentration in healthy non pregnant female volunteers were determined using a newly developed multi-component spectrophotometric method. The results of this method revealed values of SHb% in the range (0.0727-0.370%), metHb% (0.43-1.0%), HbCO% (0.4-1.52%) and oxyHb% (97.06-98.62%). Furthermore, the results of this method revealed values of blood Hb concentration in the range (12.608-15.777 g/dL). The method is highly sensitive, accurate and reproducible.

  5. Biological variability of glycated hemoglobin.

    Braga, Federica; Dolci, Alberto; Mosca, Andrea; Panteghini, Mauro

    2010-11-11

    The measurement of glycated hemoglobin (HbA(1c)) has a pivotal role in monitoring glycemic state in diabetic patients. Furthermore, the American Diabetes Association has recently recommended the use of HbA(1c) for diabetes diagnosis, but a clear definition of the clinically allowable measurement error is still lacking. Information on biological variability of the analyte can be used to achieve this goal. We systematically reviewed the published studies on the biological variation of HbA(1c) to check consistency of available data in order to accurately define analytical goals. The nine recruited studies were limited by choice of analytic methodology, population selection, protocol application and statistical analyses. There is an urgent need to determine biological variability of HbA(1c) using a specific and traceable assay, appropriate protocol and appropriate statistical evaluation of data. 2010 Elsevier B.V. All rights reserved.

  6. THE BIOCHEMISTRY OF VITREOSCILLA HEMOGLOBIN

    Benjamin C. Stark

    2012-10-01

    Full Text Available The hemoglobin (VHb from Vitreoscilla was the first bacterial hemoglobin discovered. Its structure and function have been extensively investigated, and engineering of a wide variety of heterologous organisms to express VHb has been performed to increase their growth and productivity. This strategy has shown promise in applications as far-ranging as the production of antibiotics and petrochemical replacements by microorganisms to increasing stress tolerance in plants. These applications of “VHb technology” have generally been of the “black box” variety, wherein the endpoint studied is an increase in the levels of a certain product or improved growth and survival. Their eventual optimization, however, will require a thorough understanding of the various functions and activities of VHb, and how VHb expression ripples to affect metabolism more generally. Here we review the current knowledge of these topics. VHb's functions all involve oxygen binding (and often delivery in one way or another. Several biochemical and structure-function studies have provided an insight into the molecular details of this binding and delivery. VHb activities are varied. They include supply of oxygen to oxygenases and the respiratory chain, particularly under low oxygen conditions; oxygen sensing and modulation of transcription factor activity; and detoxification of NO, and seem to require interactions of VHb with “partner proteins”. VHb expression affects the levels of ATP and NADH, although not enormously. VHb expression may affect the level of many compounds of intermediary metabolism, and, apparently, alters the levels of expression of many genes. Thus, the metabolic changes in organisms engineered to express VHb are likely to be numerous and complicated.

  7. Use and Cost of Electronic Resources in Central Library of Ferdowsi University Based on E-metrics

    Mohammad Reza Davarpanah

    2012-07-01

    Full Text Available The purpose of this study was to investigate the usage of electronic journals in Ferdowsi University, Iran based on e-metrics. The paper also aimed to emphasize the analysis of cost-benefit and the correlation between the journal impact factors and the usage data. In this study experiences of Ferdowsi University library on licensing and usage of electronic resources was evaluated by providing a cost-benefit analysis based on the cost and usage statistics of electronic resources. Vendor-provided data were also compared with local usage data. The usage data were collected by tracking web-based access locally, and by collecting vender-provided usage data. The data sources were one-year of vendor-supplied e-resource usage data such as Ebsco, Elsevier, Proquest, Emerald, Oxford and Springer and local usage data collected from the Ferdowsi university web server. The study found that actual usage values differ for vendor-provided data and local usage data. Elsevier has got the highest usage degree in searches, sessions and downloads. Statistics also showed that a small number of journals satisfy significant amount of use while the majority of journals were used less frequent and some were never used at all. The users preferred the PDF rather than HTML format. The data in subject profile suggested that the provided e-resources were best suited to certain subjects. There was no correlation between IF and electronic journal use. Monitoring the usage of e-resources gained increasing importance for acquisition policy and budget decisions. The article provided information about local metrics for the six surveyed vendors/publishers, e.g. usage trends, requests per package, cost per use as related to the scientific specialty of the university.

  8. Led Astray by Hemoglobin A1c

    Jean Chen MD

    2016-01-01

    Full Text Available Hemoglobin A1c (A1c is used frequently to diagnose and treat diabetes mellitus. Therefore, it is important be aware of factors that may interfere with the accuracy of A1c measurements. This is a case of a rare hemoglobin variant that falsely elevated a nondiabetic patient’s A1c level and led to a misdiagnosis of diabetes. A 67-year-old male presented to endocrine clinic for further management after he was diagnosed with diabetes based on an elevated A1c of 10.7%, which is approximately equivalent to an average blood glucose of 260 mg/dL. Multiple repeat A1c levels remained >10%, but his home fasting and random glucose monitoring ranged from 92 to 130 mg/dL. Hemoglobin electrophoresis and subsequent genetic analysis diagnosed the patient with hemoglobin Wayne, a rare hemoglobin variant. This variant falsely elevates A1c levels when A1c is measured using cation-exchange high-performance liquid chromatography. When the boronate affinity method was applied instead, the patient’s A1c level was actually 4.7%. Though hemoglobin Wayne is clinically silent, this patient was erroneously diagnosed with diabetes and started on an antiglycemic medication. Due to this misdiagnosis, the patient was at risk of escalation in his “diabetes management” and hypoglycemia. Therefore, it is important that providers are aware of factors that may result in hemoglobin A1c inaccuracy including hemoglobin variants.

  9. Hemoglobin Values During Pregnancy | Leffler | Nigerian Medical ...

    It is known that the iron turnover in expectant mothers is up to three times that of an average adult. This is reflected in lower hemoglobin levels. The study showed that hemoglobin levels can be maintained by taking Bio-Strath®, provided that the patients' diet contains adequate fresh fruits and vegetables, whole grains, lean ...

  10. Spin Label Studies of the Hemoglobin-Membrane Interaction During Sickle Hemoglobin Polymerization

    Falcon Dieguez, Jose E.; Rodi, Pablo; Lores Guevara, Manuel A.; Gennaro, Ana Maria

    2009-12-01

    An enhanced hemoglobin-membrane association has been previously documented in Sickle Cell Anemia. However, it is not known how this interaction is modified during the hemoglobin S polymerization process. In this work, we use a model of reconstituted erythrocytes from ghost membranes whose cytoskeleton proteins had been previously labeled with the 4-maleimido Tempo spin label, and that were subsequently resealed with hemoglobin S or A solutions. Using EPR spectroscopy, we studied the time dependence of the spectral W/S parameter, indicative of the conformational state of cytoskeleton proteins (mainly spectrin) under spontaneous deoxygenation, with the aim of detecting the eventual effects due to hemoglobin S polymerization. The differences observed in the temporal behaviour of W/S in erythrocytes reconstituted with both hemoglobins were considered as experimental evidence of an increment in hemoglobin S-membrane interaction, as a result of the polymerization process of hemoglobin S under spontaneous deoxygenation. (author)

  11. Radioimmunochemical characterization of hemoglobins Lepore and Kenya: unique antigenic determinants located on hybrid hemoglobins

    Garver, F.A.; Altay, G.; Baker, M.M.; Gravely, M.; Huisman, T.H.J.

    1978-01-01

    Antisera were produced in rabbits to the three known types of Lepore hemoglobins, which contain hybrid delta-β non-α-chains, and to hemoglobin Kenya, which has a hybrid γ-β non-α-chain. By using a sensitive radioimmunoassay technique, the absorbed antisera were shown to contain an antibody population that was specific for the hybrid hemoglobin and did not cross-react with normal hemoglobins. However, with the absorbed Lepore-specific antisera, the three known types of Lepore hemoglobins were antigenically indistinguishable from each other, suggesting that antibodies are not produced to the primary structural differences which define the three non-α-chains of the Lepore hemoglobins. These studies demonstrate that the non-α-subunits of hemoglobins Lepore and Kenya possess unique antigenic determinant sites, evidently resulting from an altered polypeptide conformation

  12. The Greenland shark Somniosus microcephalus-Hemoglobins and ligand-binding properties.

    Roberta Russo

    Full Text Available A large amount of data is currently available on the adaptive mechanisms of polar bony fish hemoglobins, but structural information on those of cartilaginous species is scarce. This study presents the first characterisation of the hemoglobin system of one of the longest-living vertebrate species (392 ± 120 years, the Arctic shark Somniosus microcephalus. Three major hemoglobins are found in its red blood cells and are made of two copies of the same α globin combined with two copies of three very similar β subunits. The three hemoglobins show very similar oxygenation and carbonylation properties, which are unaffected by urea, a very important compound in marine elasmobranch physiology. They display identical electronic absorption and resonance Raman spectra, indicating that their heme-pocket structures are identical or highly similar. The quaternary transition equilibrium between the relaxed (R and the tense (T states is more dependent on physiological allosteric effectors than in human hemoglobin, as also demonstrated in polar teleost hemoglobins. Similar to other cartilaginous fishes, we found no evidence for functional differentiation among the three isoforms. The very similar ligand-binding properties suggest that regulatory control of O2 transport may be at the cellular level and that it may involve changes in the cellular concentrations of allosteric effectors and/or variations of other systemic factors. The hemoglobins of this polar shark have evolved adaptive decreases in O2 affinity in comparison to temperate sharks.

  13. The Nernst equation applied to oxidation-reduction reactions in myoglobin and hemoglobin. Evaluation of the parameters.

    Saroff, Harry A

    Analyses of the binding of oxygen to monomers such as myoglobin employ the Mass Action equation. The Mass Action equation, as such, is not directly applicable for the analysis of the binding of oxygen to oligomers such as hemoglobin. When the binding of oxygen to hemoglobin is analyzed, models incorporating extensions of mass action are employed. Oxidation-reduction reactions of the heme group in myoglobin and hemoglobin involve the binding and dissociation of electrons. This reaction is described with the Nernst equation. The Nernst equation is applicable only to a monomeric species even if the number of electrons involved is greater than unity. To analyze the oxidation-reduction reaction in a molecule such as hemoglobin a model is required which incorporates extensions of the Nernst equation. This communication develops models employing the Nernst equation for oxidation-reduction reactions analogous to those employed for hemoglobin in the analysis of the oxygenation (binding of oxygen) reaction.

  14. Use and User Perception of Electronic Information Resources: A Case Study of Siva Institute of Frontier Technology, India

    Velmurugan Chandran

    2013-12-01

    Full Text Available The present study aims to explore the use and user perception of electronic resources in Siva Institute of Frontier Technology, India. A total number of 123 users were taken into account for the study through a questionnaire-based survey method. A well-structured questionnaire was designed and distributed to the selected 200 students and staff members. 123 copies of the questionnaires were returned dully filled in and the overall response rate was 61.50 percent. The questionnaire contained both open- and close-ended questions. The collected data were classified, analyzed, and tabulated by using simple statistical methods. This study covers the impact of electronic resources on students and faculty in their academic pursuit.

  15. Challenges in the implementation of an electronic surveillance system in a resource-limited setting: Alerta, in Peru

    Soto Giselle

    2008-11-01

    Full Text Available Abstract Background Infectious disease surveillance is a primary public health function in resource-limited settings. In 2003, an electronic disease surveillance system (Alerta was established in the Peruvian Navy with support from the U.S. Naval Medical Research Center Detachment (NMRCD. Many challenges arose during the implementation process, and a variety of solutions were applied. The purpose of this paper is to identify and discuss these issues. Methods This is a retrospective description of the Alerta implementation. After a thoughtful evaluation according to the Centers for Disease Control and Prevention (CDC guidelines, the main challenges to implementation were identified and solutions were devised in the context of a resource-limited setting, Peru. Results After four years of operation, we have identified a number of challenges in implementing and operating this electronic disease surveillance system. These can be divided into the following categories: (1 issues with personnel and stakeholders; (2 issues with resources in a developing setting; (3 issues with processes involved in the collection of data and operation of the system; and (4 issues with organization at the central hub. Some of the challenges are unique to resource-limited settings, but many are applicable for any surveillance system. For each of these challenges, we developed feasible solutions that are discussed. Conclusion There are many challenges to overcome when implementing an electronic disease surveillance system, not only related to technology issues. A comprehensive approach is required for success, including: technical support, personnel management, effective training, and cultural sensitivity in order to assure the effective deployment of an electronic disease surveillance system.

  16. RESEARCH OF INFLUENCE OF QUALITY OF ELECTRONIC EDUCATIONAL RESOURCES ON QUALITY OF TRAINING WITH USE OF DISTANCE TECHNOLOGIES

    H. M. Kravtsov

    2013-03-01

    Full Text Available Communication improving of educational processes requires today new approaches to the management arrangements and forming of educational policy in the field of distance learning, which is based on the use of modern information and communication technologies. An important step in this process is the continuous monitoring of the development and implementation of information technology and, in particular, the distance learning systems in higher educational establishments. The main objective of the monitoring is the impact assessment on the development of distance learning following the state educational standards, curricula, methodical and technical equipment and other factors; factors revelation that influence the implementation and outcomes of distance learning; results comparison of educational institution functioning and distance education systems in order to determine the most efficient ways of its development. The paper presents the analysis results of the dependence of the quality of educational services on the electronic educational resources. Trends in educational services development was studied by comparing the quality influence of electronic educational resources on the quality of educational services of higher pedagogical educational institutions of Ukraine as of 2009-2010 and 2012-2013. Generally, the analysis of the survey results allows evaluating quality of the modern education services as satisfactory and it can be said that almost 70% of the success of their future development depends on the quality of the used electronic educational resources and distance learning systems in particular.

  17. Tracking the Flow of Resources in Electronic Waste - The Case of End-of-Life Computer Hard Disk Drives.

    Habib, Komal; Parajuly, Keshav; Wenzel, Henrik

    2015-10-20

    Recovery of resources, in particular, metals, from waste flows is widely seen as a prioritized option to reduce their potential supply constraints in the future. The current waste electrical and electronic equipment (WEEE) treatment system is more focused on bulk metals, where the recycling rate of specialty metals, such as rare earths, is negligible compared to their increasing use in modern products, such as electronics. This study investigates the challenges in recovering these resources in the existing WEEE treatment system. It is illustrated by following the material flows of resources in a conventional WEEE treatment plant in Denmark. Computer hard disk drives (HDDs) containing neodymium-iron-boron (NdFeB) magnets were selected as the case product for this experiment. The resulting output fractions were tracked until their final treatment in order to estimate the recovery potential of rare earth elements (REEs) and other resources contained in HDDs. The results further show that out of the 244 kg of HDDs treated, 212 kg comprising mainly of aluminum and steel can be finally recovered from the metallurgic process. The results further demonstrate the complete loss of REEs in the existing shredding-based WEEE treatment processes. Dismantling and separate processing of NdFeB magnets from their end-use products can be a more preferred option over shredding. However, it remains a technological and logistic challenge for the existing system.

  18. HELP (INFORMATION ELECTRONIC RESOURCE "CHRONICLE OF ONU: DATES, FACTS, EVENTS": HISTORY OF UNIVERSITY IN INFORMATION SPACE

    А. М. Гавриленко

    2016-03-01

    Object of research is the help information resource "The chronicle of the Odessa national university of I. I. Mechnikov: dates, facts, events". The main objective of our article – to state the main methodological bases of creation of information resource. One of advantages of information resource is possibility of continuous updating and replenishment by new information. Main objective of creation of this information resource is systematization of material on stories of the Odessa national university of I. I. Mechnikov from the date of his basis to the present, ensuring interactive access to information on the main dates, the most significant events in life of university. The base of research are sources on the history of university, chronology of historical development, formation of infrastructure, cadres and scientific researches. In information resource the main stages of development, functioning and transformation of the Odessa University are analyzed, information on its divisions is collected. For creation of this information resource in Scientific library the method of work was developed, the main selection criteria of data are allocated. This information resource have practical value for all who is interested in history of university, historians, scientists-researchers of history of science and the city of Odessa.

  19. Oxygen Measurements in Liposome Encapsulated Hemoglobin

    Phiri, Joshua Benjamin

    Liposome encapsulated hemoglobins (LEH's) are of current interest as blood substitutes. An analytical methodology for rapid non-invasive measurements of oxygen in artificial oxygen carriers is examined. High resolution optical absorption spectra are calculated by means of a one dimensional diffusion approximation. The encapsulated hemoglobin is prepared from fresh defibrinated bovine blood. Liposomes are prepared from hydrogenated soy phosphatidylcholine (HSPC), cholesterol and dicetylphosphate using a bath sonication method. An integrating sphere spectrophotometer is employed for diffuse optics measurements. Data is collected using an automated data acquisition system employing lock-in -amplifiers. The concentrations of hemoglobin derivatives are evaluated from the corresponding extinction coefficients using a numerical technique of singular value decomposition, and verification of the results is done using Monte Carlo simulations. In situ measurements are required for the determination of hemoglobin derivatives because most encapsulation methods invariably lead to the formation of methemoglobin, a nonfunctional form of hemoglobin. The methods employed in this work lead to high resolution absorption spectra of oxyhemoglobin and other derivatives in red blood cells and liposome encapsulated hemoglobin (LEH). The analysis using singular value decomposition method offers a quantitative means of calculating the fractions of oxyhemoglobin and other hemoglobin derivatives in LEH samples. The analytical methods developed in this work will become even more useful when production of LEH as a blood substitute is scaled up to large volumes.

  20. Print and Electronic Resources: Usage Statistics at Guru Gobind Singh Indraprastha University Library

    Kapoor, Kanta

    2010-01-01

    Purpose: The purpose of this paper is to quantify the use of electronic journals in comparison with the print collections in the Guru Gobind Singh Indraprastha University Library. Design/methodology/approach: A detailed analysis was made of the use of lending services, the Xerox facility and usage of electronic journals such as Science Direct,…

  1. Understanding intention to use electronic information resources: A theoretical extension of the technology acceptance model (TAM).

    Tao, Donghua

    2008-11-06

    This study extended the Technology Acceptance Model (TAM) by examining the roles of two aspects of e-resource characteristics, namely, information quality and system quality, in predicting public health students' intention to use e-resources for completing research paper assignments. Both focus groups and a questionnaire were used to collect data. Descriptive analysis, data screening, and Structural Equation Modeling (SEM) techniques were used for data analysis. The study found that perceived usefulness played a major role in determining students' intention to use e-resources. Perceived usefulness and perceived ease of use fully mediated the impact that information quality and system quality had on behavior intention. The research model enriches the existing technology acceptance literature by extending TAM. Representing two aspects of e-resource characteristics provides greater explanatory information for diagnosing problems of system design, development, and implementation.

  2. Detection of Sickle Cell Hemoglobin in Haiti by Genotyping and Hemoglobin Solubility Tests

    Carter, Tamar E.; von Fricken, Michael; Romain, Jean R.; Memnon, Gladys; St. Victor, Yves; Schick, Laura; Okech, Bernard A.; Mulligan, Connie J.

    2014-01-01

    Sickle cell disease is a growing global health concern because infants born with the disorder in developing countries are now surviving longer with little access to diagnostic and management options. In Haiti, the current state of sickle cell disease/trait in the population is unclear. To inform future screening efforts in Haiti, we assayed sickle hemoglobin mutations using traditional hemoglobin solubility tests (HST) and add-on techniques, which incorporated spectrophotometry and insoluble hemoglobin separation. We also generated genotype data as a metric for HST performance. We found 19 of 202 individuals screened with HST were positive for sickle hemoglobin, five of whom did not carry the HbS allele. We show that spectrophotometry and insoluble hemoglobin separation add-on techniques could resolve false positives associated with the traditional HST approach, with some limitations. We also discuss the incorporation of insoluble hemoglobin separation observation with HST in suboptimal screening settings like Haiti. PMID:24957539

  3. Building and Managing Electronic Resources in Digital Era in India with Special Reference to IUCAA and NIV, Pune: A Comparative Case Study

    Sahu, H. K.; Singh, S. N.

    2015-04-01

    This paper discusses and presents a comparative case study of two libraries in Pune, India, Inter-University Centre for Astronomy and Astrophysics and Information Centre and Library of National Institute of Virology (Indian Council of Medical Research). It compares how both libraries have managed their e-resource collections, including acquisitions, subscriptions, and consortia arrangements, while also developing a collection of their own resources, including pre-prints and publications, video lectures, and other materials in an institutional repository. This study illustrates how difficult it is to manage electronic resources in a developing country like India, even though electronic resources are used more than print resources. Electronic resource management can be daunting, but with a systematic approach, various problems can be solved, and use of the materials will be enhanced.

  4. The level of the usage of the human resource information system and electronic recruitment in Croatian companies

    Snježana Pivac

    2014-12-01

    Full Text Available Performing business according to contemporary requirements influences companies for continuous usage of modern managerial tools, such as a human resource information system (HRIS and electronic recruitment (ER. Human resources have been recognised as curtail resources and the main source of a competitive advantage in creation of successful business performance. In order to attract and select the top employees, companies use quality information software for attracting internal ones, and electronic recruitment for attracting the best possible external candidates. The main aim of this paper is to research the level of the usage of HRIS and ER within medium-size and large Croatian companies. Moreover, the additional aim of this paper is to evaluate the relationship among the usage of these modern managerial tools and the overall success of human resource management within these companies. For the purpose of this paper, primary and secondary research has been conducted in order to reveal the level of the usage of HRIS and ER as well as the overall success of human resource management in Croatian companies. The companies’ classification (HRIS and ER is done by using the non-hierarchical k-means cluster method as well as the nonparametric Kruskal Wallis test. Further, the companies are ranked by the multicriteria PROMETHEE method. Relevant nonparametric tests are used for testing the overall companies’ HRM. Finally, binary logistic regression is estimated, relating binary variable HRM and HRIS development. After detailed research, it can be concluded that large Croatian companies apply HRIS in majority (with a positive relation to HRM performance, but still require certain degrees of its development.

  5. Moessbauer study of hemoglobin of diabetes

    Li Aiguo; Ni Xinbo; Cai Yingwen; Zhang Guilin; Zhang Hongde; Ge Yongxin

    2000-01-01

    The hemoglobins from normal adults (Gly-Hb 5%), people infected with diabetes (Gly-Hb 10%) and serious diabetics (Gly-Hb 15%) were investigated by Moessbauer spectroscopy at liquid nitrogen temperature. All the experimental spectra of hemoglobin are composed of three doublets corresponding to oxy-hemoglobin (Oxy-Hb), deoxy-hemoglobin (Deoxy-Hb) and low-spin hemo-chrome (Ls-Hemo) respectively. It is found that Oxy-Hb is decreasing but Deoxy-hb increasing for diabetes. Experimental results also indicate that the line-width of Moessbauer spectra of Oxy-Hb for diabetics is narrower than that for normal adults, showing that while Fe on Oxy-Hb exists in pile-up of some similar states for normal adults, but it becomes in single state for serious diabetes

  6. Methylation of hemoglobin to enhance flocculant performance

    An inexpensive bioflocculant, bovine hemoglobin (Hb), has been covalently modified through methylation of the side chain carboxyl groups of aspartic and glutamic acid residues to improve its flocculation activity. Potentiometric titration of the recovered products showed approximately 28% degree of ...

  7. Cloned Hemoglobin Genes Enhance Growth Of Cells

    Khosla, Chaitan; Bailey, James E.

    1991-01-01

    Experiments show that portable deoxyribonucleic acid (DNA) sequences incorporated into host cells make them produce hemoglobins - oxygen-binding proteins essential to function of red blood cells. Method useful in several biotechnological applications. One, enhancement of growth of cells at higher densities. Another, production of hemoglobin to enhance supplies of oxygen in cells, for use in chemical reactions requiring oxygen, as additive to serum to increase transport of oxygen, and for binding and separating oxygen from mixtures of gases.

  8. Hemoglobin levels in normal Filipino pregnant women.

    Kuizon, M D; Natera, M G; Ancheta, L P; Platon, T P; Reyes, G D; Macapinlac, M P

    1981-09-01

    The hemoglobin concentrations during pregnancy in Filipinos belonging to the upper income group, who were prescribed 105 mg elemental iron daily, and who had acceptable levels of transferrin saturation, were examined in an attempt to define normal levels. The hemoglobin concentrations for each trimester followed a Gaussian distribution. The hemoglobin values equal to the mean minus one standard deviation were 11.4 gm/dl for the first trimester and 10.4 gm/dl for the second and third trimesters. Using these values as the lower limits of normal, in one group of pregnant women the prevalence of anemia during the last two trimesters was found lower than that obtained when WHO levels for normal were used. Groups of women with hemoglobin of 10.4 to 10.9 gm/dl (classified anemic by WHO criteria but normal in the present study) and those with 11.0 gm/dl and above could not be distinguished on the basis of their serum ferritin levels nor on the degree of decrease in their hemoglobin concentration during pregnancy. Many subjects in both groups, however, had serum ferritin levels less than 12 ng/ml which indicate poor iron stores. It might be desirable in future studies to determine the hemoglobin cut-off point that will delineate subjects who are both non-anemic and adequate in iron stores using serum ferritin levels as criterion for the latter.

  9. High affinity hemoglobin and Parkinson's disease.

    Graham, Jeffrey; Hobson, Douglas; Ponnampalam, Arjuna

    2014-12-01

    Parkinson's disease (PD) is a neurodegenerative disorder characterized by the loss of dopaminergic neurons in the substantia nigra (SN) region of the midbrain. Oxidative damage in this region has been shown to play an important role in the pathogenesis of this disease. Human neurons have been discovered to contain hemoglobin, with an increased concentration seen in the neurons of the SN. High affinity hemoglobin is a clinical entity resulting from mutations that create a functional increase in the binding of hemoglobin to oxygen and an inability to efficiently unload it to tissues. This can result in a number of metabolic compensatory changes, including an elevation in circulating hemoglobin and an increase in the molecule 2,3-diphosphoglycerate (2,3-DPG). Population based studies have revealed that patients with PD have elevated hemoglobin as well as 2,3-DPG levels. Based on these observations, we hypothesize that the oxidative damage seen in PD is related to an underlying high affinity hemoglobin subtype. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. MendelWeb: An Electronic Science/Math/History Resource for the WWW.

    Blumberg, Roger B.

    This paper describes a hypermedia resource, called MendelWeb that integrates elementary biology, discrete mathematics, and the history of science. MendelWeb is constructed from Gregor Menders 1865 paper, "Experiments in Plant Hybridization". An English translation of Mendel's paper, which is considered to mark the birth of classical and…

  11. Helping Patrons Find Locally Held Electronic Resources: An Interlibrary Loan Perspective

    Johnston, Pamela

    2016-01-01

    The University of North Texas Libraries provide extensive online access to academic journals through major vendor databases. As illustrated by interlibrary loan borrowing requests for items held in our databases, patrons often have difficulty navigating the available resources. In this study, the Interlibrary Loan staff used data gathered from the…

  12. QR Codes as Finding Aides: Linking Electronic and Print Library Resources

    Kane, Danielle; Schneidewind, Jeff

    2011-01-01

    As part of a focused, methodical, and evaluative approach to emerging technologies, QR codes are one of many new technologies being used by the UC Irvine Libraries. QR codes provide simple connections between print and virtual resources. In summer 2010, a small task force began to investigate how QR codes could be used to provide information and…

  13. Eavesdropping on Electronic Guidebooks: Observing Learning Resources in Shared Listening Environments.

    Woodruff, Allison; Aoki, Paul M.; Grinter, Rebecca E.; Hurst, Amy; Szymanski, Margaret H.; Thornton, James D.

    This paper describes an electronic guidebook, "Sotto Voce," that enables visitors to share audio information by eavesdropping on each others guidebook activity. The first section discusses the design and implementation of the guidebook device, key aspects of its user interface, the design goals for the audio environment, the eavesdropping…

  14. Antimicrobial activity and safety evaluation of peptides isolated from the hemoglobin of chickens.

    Hu, Fengjiao; Wu, Qiaoxing; Song, Shuang; She, Ruiping; Zhao, Yue; Yang, Yifei; Zhang, Meikun; Du, Fang; Soomro, Majid Hussain; Shi, Ruihan

    2016-12-05

    Hemoglobin is a rich source of biological peptides. As a byproduct and even wastewater of poultry-slaughtering facilities, chicken blood is one of the most abundant source of hemoglobin. In this study, the chicken hemoglobin antimicrobial peptides (CHAP) were isolated and the antimicrobial and bactericidal activities were tested by the agarose diffusion assay, minimum inhibitory concentration (MIC) analysis, minimal bactericidal concentration (MBC) analysis, and time-dependent inhibitory and bactericidal assays. The results demonstrated that CHAP had potent and rapid antimicrobial activity against 19 bacterial strains, including 9 multidrug-resistant bacterial strains. Bacterial biofilm and NaCl permeability assays, transmission electron microscopy (TEM) and scanning electron microscopy (SEM) were further performed to detect the mechanism of its antimicrobial effect. Additionally, CHAP showed low hemolytic activity, embryo toxicity, and high stability in different temperatures and animal plasma. CHAP may have great potential for expanding production and development value in animal medication, the breeding industry and environment protection.

  15. Convergent evolution of hemoglobin switching in jawed and jawless vertebrates.

    Rohlfing, Kim; Stuhlmann, Friederike; Docker, Margaret F; Burmester, Thorsten

    2016-02-01

    During development, humans and other jawed vertebrates (Gnathostomata) express distinct hemoglobin genes, resulting in different hemoglobin tetramers. Embryonic and fetal hemoglobin have higher oxygen affinities than the adult hemoglobin, sustaining the oxygen demand of the developing organism. Little is known about the expression of hemoglobins during development of jawless vertebrates (Agnatha). We identified three hemoglobin switches in the life cycle of the sea lamprey. Three hemoglobin genes are specifically expressed in the embryo, four genes in the filter feeding larva (ammocoete), and nine genes correspond to the adult hemoglobin chains. During the development from the parasitic to the reproductive adult, the composition of hemoglobin changes again, with a massive increase of chain aHb1. A single hemoglobin chain is expressed constitutively in all stages. We further showed the differential expression of other globin genes: Myoglobin 1 is most highly expressed in the reproductive adult, myoglobin 2 expression peaks in the larva. Globin X1 is restricted to the embryo; globin X2 was only found in the reproductive adult. Cytoglobin is expressed at low levels throughout the life cycle. Because the hemoglobins of jawed and jawless vertebrates evolved independently from a common globin ancestor, hemoglobin switching must also have evolved convergently in these taxa. Notably, the ontogeny of sea lamprey hemoglobins essentially recapitulates their phylogeny, with the embryonic hemoglobins emerging first, followed by the evolution of larval and adult hemoglobins.

  16. Development and evolution of The Knowledge Hub for Pathology and related electronic resources.

    Hardwick, David F; Sinard, John; Silva, Fred

    2011-06-01

    The Knowledge Hub for Pathology was created to provide authenticated and validated knowledge for United States and Canadian Academy of Pathology members and pathologists worldwide with access to the Web. Using the material presented at the annual meeting of the United States and Canadian Academy of Pathology with existing selection and review procedures ensured that these criteria were met without added costly procedures. Further submissions for courses and research papers are provided in electronic format and funded by universities and hospitals for their creation; thus, the principal costs borne by the United States and Canadian Academy of Pathology are Web site-posting costs. Use has escalated rapidly from 2 million hits in 2002 to 51 million in 2009 with use by 35,000 pathologists from now a total of 180 countries. This true "freemium" model is a successful process as are more traditional continuing professional development course structures such as Anatomic Pathology Electronic Case Series, a "premium" model for learning electronically also sponsored by the United States and Canadian Academy of Pathology. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    Ramli, Rindra M.

    2017-01-01

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  18. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    Ramli, Rindra M.

    2017-05-03

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  19. Designing a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology

    Mirali Seyednaghavi

    2017-06-01

    Full Text Available : In the first phase of this study a model for electronic human resource management in government agencies based on new public services was explored by using software MAXQDA, then in the second phase, relationship between the elements of the theory were tested using software Smart PLS2. So the aim of this study is to design a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology. In this regard, according to Strauss and Corbin’s structured plan, five hypotheses were tested. Quantitative data analysis indicates that the pressures of the policies and global perspectives cause to move toward e-HRM. Among the contextual conditions macro structural mechanisms, considerations of actors, governance considerations have a significant impact on the strategy of new public services and therefore lead to the consequences of its implementation in public organizations. The findings suggest that e-HRM does not have a positive and meaningful impact on new public services, and in our country, although the recent political developments have somehow removed the gap between public policy makers, administrators, and the public, but there is still a long way to go.

  20. Preference and Use of Electronic Information and Resources by Blind/Visually Impaired in NCR Libraries in India

    Shailendra Kumar

    2013-06-01

    Full Text Available This paper aims to determine the preference and use of electronic information and resources by blind/visually impaired users in the leading National Capital Region (NCR libraries of India. Survey methodology has been used as the basic research tool for data collection with the help of questionnaires. The 125 in total users surveyed in all the five libraries were selected randomly on the basis of willingness of the users with experience of working in digital environments to participate in the survey. The survey results were tabulated and analyzed with descriptive statistics methods using Excel software and 'Stata version 11'. The findings reveal that ICT have a positive impact in the lives of people with disabilities as it helps them to work independently and increases the level of confidence among them. The Internet is the most preferred medium of access to information among the majority of blind/visually impaired users. The 'Complexity of content available on the net' is found as the major challenge faced during Internet use by blind users of NCR libraries. 'Audio books on CDs/DVDs and DAISY books' are the most preferred electronic resources among the majority of blind/visually impaired users. This study will help the library professionals and organizations/institutions serving people with disabilities to develop effective library services for blind/visually impaired users in the digital environment on the basis of findings on information usage behavior in the study.

  1. Internet and electronic resources for inflammatory bowel disease: a primer for providers and patients.

    Fortinsky, Kyle J; Fournier, Marc R; Benchimol, Eric I

    2012-06-01

    Patients with inflammatory bowel disease (IBD) are increasingly turning to the Internet to research their condition and engage in discourse on their experiences. This has resulted in new dynamics in the relationship between providers and their patients, with misinformation and advertising potentially presenting barriers to the cooperative patient-provider partnership. This article addresses important issues of online IBD-related health information and social media activity, such as quality, reliability, objectivity, and privacy. We reviewed the medical literature on the quality of online information provided to IBD patients, and summarized the most commonly accessed Websites related to IBD. We also assessed the activity on popular social media sites (such as Facebook, Twitter, and YouTube), and evaluated currently available applications for use by IBD patients and providers on mobile phones and tablets. Through our review of the literature and currently available resources, we developed a list of recommended online resources to strengthen patient participation in their care by providing reliable, comprehensive educational material. Copyright © 2011 Crohn's & Colitis Foundation of America, Inc.

  2. The Features of Moessbauer Spectra of Hemoglobins: Approximation by Superposition of Quadrupole Doublets or by Quadrupole Splitting Distribution?

    Oshtrakh, M. I.; Semionkin, V. A.

    2004-01-01

    Moessbauer spectra of hemoglobins have some features in the range of liquid nitrogen temperature: a non-Lorentzian asymmetric line shape for oxyhemoglobins and symmetric Lorentzian line shape for deoxyhemoglobins. A comparison of the approximation of the hemoglobin Moessbauer spectra by a superposition of two quadrupole doublets and by a distribution of the quadrupole splitting demonstrates that a superposition of two quadrupole doublets is more reliable and may reflect the non-equivalent iron electronic structure and the stereochemistry in the α- and β-subunits of hemoglobin tetramers.

  3. Nitrosyl hemoglobins: EPR above 80 K

    Wajnberg, E.; Bemski, G.; El-Jaick, L.J.; Alves, O.C.

    1995-03-01

    The EPR spectra of nitrosyl hemoglobin and myoglobin in different conditions (native, denatured and lyophilized), as well as of hematin-NO were obtained in the temperature range of 80 K-280 K. There is a substantial and reversible.decrease of the areas of the EPR spectra of all the hemoglobin samples above 150 K. The interpretation of the results implies the existence of two conformational states in thermal equilibrium only one of which is EPR detectable. Thermodynamical parameters are determined for the hexa and penta-coordinated cases. (author). 25 refs, 3 figs.

  4. Nitrosyl hemoglobins: EPR above 80 K

    Wajnberg, E.; Bemski, G.; El-Jaick, L.J.; Alves, O.C.

    1995-03-01

    The EPR spectra of nitrosyl hemoglobin and myoglobin in different conditions (native, denatured and lyophilized), as well as of hematin-NO were obtained in the temperature range of 80 K-280 K. There is a substantial and reversible.decrease of the areas of the EPR spectra of all the hemoglobin samples above 150 K. The interpretation of the results implies the existence of two conformational states in thermal equilibrium only one of which is EPR detectable. Thermodynamical parameters are determined for the hexa and penta-coordinated cases. (author). 25 refs, 3 figs

  5. Electronic medical records in diabetes consultations: participants' gaze as an interactional resource.

    Rhodes, Penny; Small, Neil; Rowley, Emma; Langdon, Mark; Ariss, Steven; Wright, John

    2008-09-01

    Two routine consultations in primary care diabetes clinics are compared using extracts from video recordings of interactions between nurses and patients. The consultations were chosen to present different styles of interaction, in which the nurse's gaze was either primarily toward the computer screen or directed more toward the patient. Using conversation analysis, the ways in which nurses shift both gaze and body orientation between the computer screen and patient to influence the style, pace, content, and structure of the consultation were investigated. By examining the effects of different levels of engagement between the electronic medical record and the embodied patient in the consultation room, we argue for the need to consider the contingent nature of the interface of technology and the person in the consultation. Policy initiatives designed to deliver what is considered best-evidenced practice are modified in the micro context of the interactions of the consultation.

  6. Granulometric composition study of mineral resources using opto-electronic devices and Elsieve software system

    Kaminski Stanislaw

    2016-01-01

    Full Text Available The use of mechanical sieves has a great impact on measurement results because occurrence of anisometric particles causes undercounting the average size. Such errors can be avoided by using opto-electronic measuring devices that enable measurement of particles from 10 μm up to a few dozen millimetres in size. The results of measurement of each particle size fraction are summed up proportionally to its weight with the use of Elsieve software system and for every type of material particle-size distribution can be obtained. The software allows further statistical interpretation of the results. Beam of infrared radiation identifies size of particles and counts them precisely. Every particle is represented by an electronic impulse proportional to its size. Measurement of particles in aqueous suspension that replaces the hydrometer method can be carried out by using the IPS L analyser (range from 0.2 to 600 μm. The IPS UA analyser (range from 0.5 to 2000 μm is designed for measurement in the air. An ultrasonic adapter enables performing measurements of moist and aggregated particles from 0.5 to 1000 μm. The construction and software system allow to determine second dimension of the particle, its shape coefficient and specific surface area. The AWK 3D analyser (range from 0.2 to 31.5 mm is devoted to measurement of various powdery materials with subsequent determination of particle shape. The AWK B analyser (range from 1 to 130 mm measures materials of thick granulation and shape of the grains. The presented method of measurement repeatedly accelerates and facilitates study of granulometric composition.

  7. Development and validation of a noncontact spectroscopic device for hemoglobin estimation at point-of-care

    Sarkar, Probir Kumar; Pal, Sanchari; Polley, Nabarun; Aich, Rajarshi; Adhikari, Aniruddha; Halder, Animesh; Chakrabarti, Subhananda; Chakrabarti, Prantar; Pal, Samir Kumar

    2017-05-01

    Anemia severely and adversely affects human health and socioeconomic development. Measuring hemoglobin with the minimal involvement of human and financial resources has always been challenging. We describe a translational spectroscopic technique for noncontact hemoglobin measurement at low-resource point-of-care settings in human subjects, independent of their skin color, age, and sex, by measuring the optical spectrum of the blood flowing in the vascular bed of the bulbar conjunctiva. We developed software on the LabVIEW platform for automatic data acquisition and interpretation by nonexperts. The device is calibrated by comparing the differential absorbance of light of wavelength 576 and 600 nm with the clinical hemoglobin level of the subject. Our proposed method is consistent with the results obtained using the current gold standard, the automated hematology analyzer. The proposed noncontact optical device for hemoglobin estimation is highly efficient, inexpensive, feasible, and extremely useful in low-resource point-of-care settings. The device output correlates with the different degrees of anemia with absolute and trending accuracy similar to those of widely used invasive methods. Moreover, the device can instantaneously transmit the generated report to a medical expert through e-mail, text messaging, or mobile apps.

  8. Predictors of hemoglobin in Danish blood donors

    Kotzé, Sebastian R; Pedersen, Ole B; Petersen, Mikkel S

    2015-01-01

    BACKGROUND: It is well known that blood donors are at increased risk of iron deficiency and subsequent development of iron deficiency anemia. We aimed to investigate the effect of factors influencing hemoglobin (Hb) levels. STUDY DESIGN AND METHODS: Initiated in 2010, the Danish Blood Donor Study...

  9. Rheological Variations among Nigerians with Different Hemoglobin ...

    Some Hemorheological determinants such as whole blood viscosity (WBV) and plasma viscosity (PV) and Plasma Fibrinogen Concentration (PFC) were measured with standard methods. We recorded a relatively unchanged whole blood viscosities in subjects with various hemoglobin genotypes (AA, AS and SS; P>0.05, ...

  10. High-altitude adaptations in vertebrate hemoglobins

    Weber, Roy E.

    2007-01-01

    Vertebrates at high altitude are subjected to hypoxic conditions that challenge aerobic metabolism. O2 transport from the respiratory surfaces to tissues requires matching between the O2 loading and unloading tensions and theO2-affinity of blood, which is an integrated function of hemoglobin......, birds and ectothermic vertebrates at high altitude....

  11. Constraints on mutational pathways of hemoglobin evolution

    Kumar, Amit; Natarajan, Chandrasekhar; Moriyama, Hideaki

    2016-01-01

    amino acid substitutions that occurred during an evolutionary reduction in hemoglobin (Hb)-O2 affinity in nightjars (nocturnal birds in the family Caprimulgidae).We selected nightjar Hbs for experimental study because ancestral sequence reconstructions indicated that the evolved reduction in Hb-O2...

  12. A new hemoglobin gene from soybean: a role for hemoglobin in all plants

    Anderson, C R; Jensen, E O; LLewellyn, D J

    1996-01-01

    We have isolated a new hemoglobin gene from soybean. It is expressed in cotyledons, stems of seedlings, roots, young leaves, and in some cells in the nodules that are associated with the nitrogen-fixing Bradyrhizobium symbiont. This contrasts with the expression of the leghemoglobins, which...... are active only in the infected cells of the nodules. The deduced protein sequence of the new gene shows only 58% similarity to one of the soybean leghemoglobins, but 85-87% similarity to hemoglobins from the nonlegumes Parasponia, Casuarina, and barley. The pattern of expression and the gene sequence...... indicate that this new gene is a nonsymbiotic legume hemoglobin. The finding of this gene in legumes and similar genes in other species strengthens our previous suggestion that genomes of all plants contain hemoglobin genes. The specialized leghemoglobin gene family may have arisen from a preexisting...

  13. Alpha chain hemoglobins with electrophoretic mobility similar to that of hemoglobin S in a newborn screening program

    Marcilene Rezende Silva

    2013-01-01

    Full Text Available OBJECTIVE: To characterize alpha-chain variant hemoglobins with electric mobility similar to that of hemoglobin S in a newborn screening program. METHODS: βS allele and alpha-thalassemia deletions were investigated in 14 children who had undefined hemoglobin at birth and an electrophoretic profile similar to that of hemoglobin S when they were six months old. Gene sequencing and restriction enzymes (DdeI, BsaJI, NlaIV, Bsu36I and TaqI were used to identify hemoglobins. Clinical and hematological data were obtained from children who attended scheduled medical visits. RESULTS: The following alpha chain variants were found: seven children with hemoglobin Hasharon [alpha2 47(CE5 Asp>His, HbA2:c.142G>C], all associated with alpha-thalassemia, five with hemoglobin Ottawa [alpha1 15(A13 Gly>Arg, HBA1:c.46G>C], one with hemoglobin St Luke's [alpha1 95(G2 Pro>Arg, HBA1:c.287C>G] and another one with hemoglobin Etobicoke [alpha212 84(F5 Ser>Arg, HBA212:c.255C>G]. Two associations with hemoglobin S were found: one with hemoglobin Ottawa and one with hemoglobin St Luke's. The mutation underlying hemoglobin Etobicoke was located in a hybrid α212 allele in one child. There was no evidence of clinically relevant hemoglobins detected in this study. CONCLUSION: Apparently these are the first cases of hemoglobin Ottawa, St Luke's, Etobicoke and the α212 gene described in Brazil. The hemoglobins detected in this study may lead to false diagnosis of sickle cell trait or sickle cell disease when only isoelectric focusing is used in neonatal screening. Additional tests are necessary for the correct identification of hemoglobin variants.

  14. Alpha chain hemoglobins with electrophoretic mobility similar to that of hemoglobin S in a newborn screening program.

    Silva, Marcilene Rezende; Sendin, Shimene Mascarenhas; Araujo, Isabela Couto de Oliveira; Pimentel, Fernanda Silva; Viana, Marcos Borato

    2013-01-01

    To characterize alpha-chain variant hemoglobins with electric mobility similar to that of hemoglobin S in a newborn screening program. β(S) allele and alpha-thalassemia deletions were investigated in 14 children who had undefined hemoglobin at birth and an electrophoretic profile similar to that of hemoglobin S when they were six months old. Gene sequencing and restriction enzymes (DdeI, BsaJI, NlaIV, Bsu36I and TaqI) were used to identify hemoglobins. Clinical and hematological data were obtained from children who attended scheduled medical visits. THE FOLLOWING ALPHA CHAIN VARIANTS WERE FOUND: seven children with hemoglobin Hasharon [alpha2 47(CE5) Asp>His, HbA2:c.142G>C], all associated with alpha-thalassemia, five with hemoglobin Ottawa [alpha1 15(A13) Gly>Arg, HBA1:c.46G>C], one with hemoglobin St Luke's [alpha1 95(G2) Pro>Arg, HBA1:c.287C>G] and another one with hemoglobin Etobicoke [alpha212 84(F5) Ser>Arg, HBA212:c.255C>G]. Two associations with hemoglobin S were found: one with hemoglobin Ottawa and one with hemoglobin St Luke's. The mutation underlying hemoglobin Etobicoke was located in a hybrid α212 allele in one child. There was no evidence of clinically relevant hemoglobins detected in this study. Apparently these are the first cases of hemoglobin Ottawa, St Luke's, Etobicoke and the α212 gene described in Brazil. The hemoglobins detected in this study may lead to false diagnosis of sickle cell trait or sickle cell disease when only isoelectric focusing is used in neonatal screening. Additional tests are necessary for the correct identification of hemoglobin variants.

  15. Green Supply Chain Collaboration for Fashionable Consumer Electronics Products under Third-Party Power Intervention—A Resource Dependence Perspective

    Jiuh-Biing Sheu

    2014-05-01

    Full Text Available Under third-party power intervention (TPPI, which increases uncertainty in task environments, complex channel power interplays and restructuring are indispensable among green supply chain members as they move toward sustainable collaborative relationships for increased viability and competitive advantage. From the resource dependence perspective, this work presents a novel conceptual model to investigate the influence of political and social power on channel power restructuring and induced green supply chain collaboration in brander-retailer bidirectional green supply chains of fashionable consumer electronics products (FCEPs. An FCEP refers to the consumer electronics product (e.g., personal computers, mobile phones, computer notebooks, and game consoles with the features of a well-known brand associated, a short product lifecycle, timely and fashionable design fit for market trends, and quick responsiveness to the variations of market demands. The proposed model is tested empirically using questionnaire data obtained from retailers in the FCEP brander-retailer distribution channels. Analytical results reveal that as an extension of political and social power, TPPI positively affects the reciprocal interdependence of dyadic members and reduces power asymmetry, thereby enhancing the collaborative relationship of dyadic members and leading to improved green supply chain performance. Therein, reciprocal interdependence underlying collaborative relationship is the key to reducing the external environmental uncertainties in the TPPI context.

  16. The management of online resources and long-term saving of electronic documents by transfer into the digital space

    Marius Daniel MAREŞ

    2011-12-01

    The electronic archive refers to the electronic storage system, along with the totality of electronic-type stored documents, while using as storage support any environment that can support storing and from which an electronic document can be presented.

  17. Lyophilized bovine hemoglobin as a possible reference material for the determination of hemoglobin derivatives in human blood

    Maas, BHA; Buursma, A; Ernst, RAJ; Maas, AHJ; Zijlstra, WG

    1998-01-01

    We investigated the suitability of a lyophilized bovine hemoglobin (LBH) preparation containing various fractions of oxyhemoglobin (O(2)Hb), carboxyhemoglobin (COHb), and methemoglobin (MetHb) for quality assessment in multicomponent analysis (MCA) of hemoglobin derivatives. It was demonstrated that

  18. Lyophilized bovine hemoglobin as a possible reference material for the determination of hemoglobin derivatives in human blood

    Maas, BHA; Buursma, A; Ernst, RAJ; Maas, AHJ; Zijlstra, WG

    We investigated the suitability of a lyophilized bovine hemoglobin (LBH) preparation containing various fractions of oxyhemoglobin (O(2)Hb), carboxyhemoglobin (COHb), and methemoglobin (MetHb) for quality assessment in multicomponent analysis (MCA) of hemoglobin derivatives. It was demonstrated that

  19. The Reaction of Oxy Hemoglobin with Nitrite

    Hathazi, Denisa; Scurtu, Florina; Bischin, Cristina

    2018-01-01

    The autocatalytic reaction between nitrite and the oxy form of globins involves free radicals. For myoglobin (Mb), an initial binding of nitrite to the iron-coordinated oxygen molecule was proposed; the resulting ferrous-peroxynitrate species was not detected, but its decay product, the high...... to a simple kinetic model involving a transient met-aqua form, in contrast to the ferryl detected in the case of Mb in a similar reaction sequence. These data are in line with a previous observation of a transient accumulation of ferryl Hb under auto-catalytic conditions at much lower concentrations......-peroxynitrate. Density functional theory (DFT) calculations support this latter assignment. The reaction allows for differentiating between the reactivities of various chemically modified hemoglobins, including candidates for blood substitutes. Polymerization of hemoglobin slows the nitrite-induced oxidation, in sharp...

  20. Hemoglobin promotes somatic embryogenesis in peanut cultures.

    Jayabalan, N; Anthony, P; Davey, M R; Power, J B; Lowe, K C

    2004-02-01

    Critical parameters influencing somatic embryogenesis include growth regulators and oxygen supply. Consequently, the present investigation has focused on optimization of a somatic embryogenic system for peanut (Arachis hypogaea L.) through media supplementation with the auxin, picloram. The latter at 30 mg L(-1) was optimal for inducing regeneration of somatic embryos from cultured explants of zygotic embryos. In contrast, somatic embryogenesis did not occur in the absence of this growth regulator. An assessment has also been made of the beneficial effect on somatic embryogenesis and plant regeneration of the commercial hemoglobin (Hb) solution, Erythrogen. Hemoglobin at 1:50 and 1:100 (v:v) stimulated increases in mean fresh weight (up to a maximum of 57% over control), mean number of explants producing somatic embryos (15%) and mean number of somatic embryos per explant (29%).

  1. Radio-ligand immunoassay for human hemoglobin variants

    Javid, J.; Pettis, P.K.; Miller, J.E.

    1981-01-01

    A quantitative method is described for the individual assay of human hemoglobin variants occurring singly or in mixture. The hemoglobin to be assayed is bound to specific antibody; the immune complex is attached to protein A-containing S. aureus and removed from the mixture. The hemoglobin thus isolated is quantified by its ability to bind radiolabeled haptoglobin. The technique is accurate and distinguishes among the 4 hemoglobins tested, namely Hb A, S, C and F. It has the advantage over conventional radioimmunoassay that a single probe, radiolabeled haptoglobin, is needed for the specific assay of any hemoglobin. (Auth.)

  2. Development of an Electronic Medical Record Based Alert for Risk of HIV Treatment Failure in a Low-Resource Setting

    Puttkammer, Nancy; Zeliadt, Steven; Balan, Jean Gabriel; Baseman, Janet; Destiné, Rodney; Domerçant, Jean Wysler; France, Garilus; Hyppolite, Nathaelf; Pelletier, Valérie; Raphael, Nernst Atwood; Sherr, Kenneth; Yuhas, Krista; Barnhart, Scott

    2014-01-01

    Background The adoption of electronic medical record systems in resource-limited settings can help clinicians monitor patients' adherence to HIV antiretroviral therapy (ART) and identify patients at risk of future ART failure, allowing resources to be targeted to those most at risk. Methods Among adult patients enrolled on ART from 2005–2013 at two large, public-sector hospitals in Haiti, ART failure was assessed after 6–12 months on treatment, based on the World Health Organization's immunologic and clinical criteria. We identified models for predicting ART failure based on ART adherence measures and other patient characteristics. We assessed performance of candidate models using area under the receiver operating curve, and validated results using a randomly-split data sample. The selected prediction model was used to generate a risk score, and its ability to differentiate ART failure risk over a 42-month follow-up period was tested using stratified Kaplan Meier survival curves. Results Among 923 patients with CD4 results available during the period 6–12 months after ART initiation, 196 (21.2%) met ART failure criteria. The pharmacy-based proportion of days covered (PDC) measure performed best among five possible ART adherence measures at predicting ART failure. Average PDC during the first 6 months on ART was 79.0% among cases of ART failure and 88.6% among cases of non-failure (pART initiation were added to PDC, the risk score differentiated between those who did and did not meet failure criteria over 42 months following ART initiation. Conclusions Pharmacy data are most useful for new ART adherence alerts within iSanté. Such alerts offer potential to help clinicians identify patients at high risk of ART failure so that they can be targeted with adherence support interventions, before ART failure occurs. PMID:25390044

  3. Development of an electronic medical record based alert for risk of HIV treatment failure in a low-resource setting.

    Nancy Puttkammer

    Full Text Available The adoption of electronic medical record systems in resource-limited settings can help clinicians monitor patients' adherence to HIV antiretroviral therapy (ART and identify patients at risk of future ART failure, allowing resources to be targeted to those most at risk.Among adult patients enrolled on ART from 2005-2013 at two large, public-sector hospitals in Haiti, ART failure was assessed after 6-12 months on treatment, based on the World Health Organization's immunologic and clinical criteria. We identified models for predicting ART failure based on ART adherence measures and other patient characteristics. We assessed performance of candidate models using area under the receiver operating curve, and validated results using a randomly-split data sample. The selected prediction model was used to generate a risk score, and its ability to differentiate ART failure risk over a 42-month follow-up period was tested using stratified Kaplan Meier survival curves.Among 923 patients with CD4 results available during the period 6-12 months after ART initiation, 196 (21.2% met ART failure criteria. The pharmacy-based proportion of days covered (PDC measure performed best among five possible ART adherence measures at predicting ART failure. Average PDC during the first 6 months on ART was 79.0% among cases of ART failure and 88.6% among cases of non-failure (p<0.01. When additional information including sex, baseline CD4, and duration of enrollment in HIV care prior to ART initiation were added to PDC, the risk score differentiated between those who did and did not meet failure criteria over 42 months following ART initiation.Pharmacy data are most useful for new ART adherence alerts within iSanté. Such alerts offer potential to help clinicians identify patients at high risk of ART failure so that they can be targeted with adherence support interventions, before ART failure occurs.

  4. Induction of nano pore in Agrobacterial hemoglobin

    Mojtaba Tousheh

    2014-01-01

    Full Text Available Introduction: A variety of oxygen-transport and -binding proteins exist in organisms including bacteria, protozoans, and fungi all have hemoglobin-like proteins. In addition to dealing with transport and sensing of oxygen, they may also deal with NO2, CO2, sulfide compounds, and even O2 scavenging in environments. Also they detoxified chlorinated materials like P450 enzymes and peroxidases and use as a detector of nitrate and hydrogen peroxide. Pore-forming bacterial globins are interested for filtration. Materials and methods: Although there are data for bacterial toxin as a filter, here we used Agrobacterial hem to induce nano pore in the heme structure using point mutation. Results: Investigations showed that three amino acids leucine 76, alanine 83 and histidine 80 are important for pore formation in Agrobacterium hemoglobin. A point mutation on leucine 76 to glycine, histidine 80 to asparagine and alanine 83 to lysine step by step led to create the nano pore 0.7- 0.8 nm in the globin. Discussion and conclusion: These mutations in bacterial hemoglobin increase the stability when mutation is with it’s at pH7. This mutation decreases the aliphatic index however increase the stability index.

  5. Imidazolidinone adducts of peptides and hemoglobin

    San George, R.C.; Hoberman, H.D.

    1986-01-01

    Acetaldehyde reacts selectively with the terminal amino groups of the α and β chains of hemoglobin to form stable adducts, the structures of which, based on 13 C NMR studies, are proposed to be diastereomeric 2-methyl imidazolidin-4-ones. In this scheme, acetaldelhyde forms a reversible Schiff base with the α-amino groups of the polypeptide chains which cyclize with the amide nitrogen of the first peptide bond to form the stable imidazolidinone adducts. In support of this mechanism, the authors found that in following the reaction of the peptide val-gly-gly with [1,2- 13 C] acetaldehyde, 13 C NMR resonances attributed to a Schiff base (δ = 170 ppm) were observed which slowly disappeared prior to appearance of resonances from a pair of stable adducts (δ = 70 and 71 ppm) believed to be the diastereomeric imidazolidinones. Schiff base formation appeared to limit the overall rate. Tetraglycine reacted in a similar manner but with a resonance from a single stable adduct observed representing the enantiomeric imidazolidinone adducts of this peptide. Peptides with proline in position 2 should be incapable of forming imidazolidinones, and the authors found that ala-pro-gly did in fact fail to form a stable adduct with acetaldehyde. The 2-methyl imidazolidin-4-one adducts of hemoglobin may be useful in determining the contribution of the amino terminal groups to the structure and functional properties of hemoglobins

  6. Innovative direct energy conversion systems using electronic adiabatic processes of electron fluid in solid conductors: new plants of electrical power and hydrogen gas resources without environmental pollutions

    Kondoh, Y.; Kondo, M.; Shimoda, K.; Takahashi, T.

    2001-07-01

    It is shown that using a novel recycling process of the environmental thermal energy, innovative permanent auto-working direct energy converter systems (PA-DEC systems) from the environmental thermal to electrical and/or chemical potential (TE/CP) energies, abbreviated as PA-TE/CP-DEC systems, can be used for new auto-working electrical power plants and the plants of the compressible and conveyable hydrogen gas resources at various regions in the whole world, with contributions to the world peace and the economical development in the south part of the world. It is shown that the same physical mechanism by free electrons and electrical potential determined by temperature in conductors, which include semiconductors, leads to the Peltier effect and the Seebeck one. It is experimentally clarified that the long distance separation between two π type elements of the heat absorption (HAS) and the production one (HPS) of the Peltier effect circuit system or between the higher temperature side (HTS) and the lower one (LTS) of the Seebeck effect circuit one does not change in the whole for the both effects. By using present systems, we do not need to use petrified fuels such as coals, oils, and natural gases in order to decrease the greenhouse effect by the CO 2 surrounding the earth. Furthermore, we do not need plats of nuclear fissions that left radiating wastes, i.e., with no environmental pollutions. The PA-TE/CP-DEC systems can be applicable for several km scale systems to the micro ones, such as the plants of the electrical power, the compact transportable hydrogen gas resources, a large heat energy container, which can be settled at far place from thermal energy absorbing area, the refrigerators, the air conditioners, home electrical apparatuses, and further the computer elements. It is shown that the simplest PA-TE/CP-DEC system can be established by using only the Seebeck effect components and the resolving water ones. It is clarified that the externally applied

  7. Small angle X-ray scattering on concentrated hemoglobin solutions

    Zinke, M.; Damaschun, G.; Mueller, J.J.; Ruckpaul, K.

    1978-01-01

    The small-angle X-ray scattering technique was used to determine the intermolecular structure and interaction potentials in oxi-and deoxi-hemoglobin solutions. The pair correlation function obtained by the ZERNICKE-PRINS equation characterizes the intermolecular structure of the hemoglobin molecules. The intermolecular structure is concentration dependent. The hemoglobin molecules have a 'short range order structure' with a range of about 4 molecule diameters at 324 g/l. The potential functions of the hemoglobin-hemoglobin interaction have been determined on the basis of fluid theories. Except for the deoxi-hemoglobin solution having the concentration 370 g/l, the pair interaction consists in a short repulsion and a weak short-range attraction against kT. The potential minimum is between 1.2 - 1.5 nm above the greatest hemoglobin diameter. (author)

  8. Consumer reports [electronic resource

    1942-01-01

    ... only. A limited number of selected reports, advice on product selection and safety alerts are freely available, as are a five year listing of product recalls, a listing of major consumer product...

  9. The electronic Rothamsted Archive (e-RA), an online resource for data from the Rothamsted long-term experiments.

    Perryman, Sarah A M; Castells-Brooke, Nathalie I D; Glendining, Margaret J; Goulding, Keith W T; Hawkesford, Malcolm J; Macdonald, Andy J; Ostler, Richard J; Poulton, Paul R; Rawlings, Christopher J; Scott, Tony; Verrier, Paul J

    2018-05-15

    The electronic Rothamsted Archive, e-RA (www.era.rothamsted.ac.uk) provides a permanent managed database to both securely store and disseminate data from Rothamsted Research's long-term field experiments (since 1843) and meteorological stations (since 1853). Both historical and contemporary data are made available via this online database which provides the scientific community with access to a unique continuous record of agricultural experiments and weather measured since the mid-19 th century. Qualitative information, such as treatment and management practices, plans and soil information, accompanies the data and are made available on the e-RA website. e-RA was released externally to the wider scientific community in 2013 and this paper describes its development, content, curation and the access process for data users. Case studies illustrate the diverse applications of the data, including its original intended purposes and recent unforeseen applications. Usage monitoring demonstrates the data are of increasing interest. Future developments, including adopting FAIR data principles, are proposed as the resource is increasingly recognised as a unique archive of data relevant to sustainable agriculture, agroecology and the environment.

  10. Principles of formation of the content of an educational electronic resource on the basis of general and didactic patterns of learning

    Ольга Юрьевна Заславская

    2018-12-01

    Full Text Available The article considers the influence of the development of technical means of teaching on the effectiveness of educational and methodical resources. Modern opportunities of information and communication technologies allow creating electronic educational resources that represent educational information that automates the learning process, provide information assistance, if necessary, collect and process statistical information on the degree of development of the content of the school material by schoolchildren, set an individual trajectory of learning, and so on. The main principle of data organization is the division of the training course into separate sections on the thematic elements and components of the learning process. General regularities include laws that encompass the entire didactic system, and in specific (particular cases, those whose actions extend to a separate component (aspect of the system. From the standpoint of the existence of three types of electronic training modules in the aggregate content of the electronic learning resource - information, control and module of practical classes - the principles of the formation of the electronic learning resource, in our opinion, should regulate all these components. Each of the certain principles is considered in the groups: scientific orientation, methodological orientation, systemic nature, accounting of interdisciplinary connections, fundamentalization, systematic and dosage sequence, rational use of study time, accessibility, minimization, operationalization of goals, unified identification diagnosis.

  11. The module of methodical support in system of electronic educational resources as the innovative element of the modern maintenance of formation

    Ольга Николаевна Крылова

    2009-06-01

    Full Text Available The article introduces some results of research, which were devoted to evaluation of tearches' mobility to introduce innovations in the contents of education. The author considers innovative potential of modules of the methodical support for system of electronic educational resources.

  12. Charting a Course through CORAL: Texas A&M University Libraries' Experience Implementing an Open-Source Electronic Resources Management System

    Hartnett, Eric; Beh, Eugenia; Resnick, Taryn; Ugaz, Ana; Tabacaru, Simona

    2013-01-01

    In 2010, after two previous unsuccessful attempts at electronic resources management system (ERMS) implementation, Texas A&M University (TAMU) Libraries set out once again to find an ERMS that would fit its needs. After surveying the field, TAMU Libraries selected the University of Notre Dame Hesburgh Libraries-developed, open-source ERMS,…

  13. Relationship of Baseline Hemoglobin Level with Serum Ferritin, Postphlebotomy Hemoglobin Changes, and Phlebotomy Requirements among HFE C282Y Homozygotes

    Seyed Ali Mousavi

    2015-01-01

    Full Text Available Objectives. We aimed to examine whether baseline hemoglobin levels in C282Y-homozygous patients are related to the degree of serum ferritin (SF elevation and whether patients with different baseline hemoglobin have different phlebotomy requirements. Methods. A total of 196 patients (124 males and 72 females who had undergone therapeutic phlebotomy and had SF and both pre- and posttreatment hemoglobin values were included in the study. Results. Bivariate correlation analysis suggested that baseline SF explains approximately 6 to 7% of the variation in baseline hemoglobin. The results also showed that males who had higher (≥150 g/L baseline hemoglobin levels had a significantly greater reduction in their posttreatment hemoglobin despite requiring fewer phlebotomies to achieve iron depletion than those who had lower (<150 g/L baseline hemoglobin, regardless of whether baseline SF was below or above 1000 µg/L. There were no significant differences between hemoglobin subgroups regarding baseline and treatment characteristics, except for transferrin saturation between male subgroups with SF above 1000 µg/L. Similar differences were observed when females with higher (≥138 g/L baseline hemoglobin were compared with those with lower (<138 g/L baseline hemoglobin. Conclusion. Dividing C282Y-homozygous patients into just two subgroups according to the degree of baseline SF elevation may obscure important subgroup variations.

  14. Interaction of thyroid hormone and hemoglobin: nature of the interaction and effect of hemoglobin on thyroid hormone radioimmunoassay

    Davis, P.J.; Yoshida, K.; Schoenl, M.

    1980-01-01

    Gel filtration of human erythrocyte (RBC) lysate incubated with labeled thyroxine (Tu) or triiodothyronine (Tt) revealed co-elution of a major iodothyronine-binding fraction (R-2) and hemoglobin. Solutions of purified human hemoglobin and Tt also showed co-elution of hormone and hemoglobin. Because hematin and protoporphyrin were shown to bind labeled Tt, the oxygen-binding site on hemoglobin was excluded as the site of iodothyronine-hemoglobin interaction. Analysis of hormone binding by heme and globin moieties showed Tt binding to be limited to the heme fraction. Addition of excess unlabeled Tt to hemoglobin or heme incubated with labeled Tt indicated 75% to 90% of hormone binding was poorly dissociable. These observations suggested that the presence of hemoglobin in RBC lysate or in serum could influence the measurement of Tu and Tt by specific radioimmunoassay (RIA). Subsequent studies of the addition to serum of human hemoglobin revealed a significant reduction in Tt and Tu detectable by RIA in the presence of this protein. The effect was influenced by the concentration of hemoglobin and by duration and temperature of incubations of hemoglobin and serum prior to RIA

  15. Relationship of Baseline Hemoglobin Level with Serum Ferritin, Postphlebotomy Hemoglobin Changes, and Phlebotomy Requirements among HFE C282Y Homozygotes

    Mousavi, Seyed Ali; Mahmood, Faiza; Aandahl, Astrid; Knutsen, Teresa Risopatron; Llohn, Abid Hussain

    2015-01-01

    Objectives. We aimed to examine whether baseline hemoglobin levels in C282Y-homozygous patients are related to the degree of serum ferritin (SF) elevation and whether patients with different baseline hemoglobin have different phlebotomy requirements. Methods. A total of 196 patients (124 males and 72 females) who had undergone therapeutic phlebotomy and had SF and both pre- and posttreatment hemoglobin values were included in the study. Results. Bivariate correlation analysis suggested that baseline SF explains approximately 6 to 7% of the variation in baseline hemoglobin. The results also showed that males who had higher (≥150 g/L) baseline hemoglobin levels had a significantly greater reduction in their posttreatment hemoglobin despite requiring fewer phlebotomies to achieve iron depletion than those who had lower (baseline hemoglobin, regardless of whether baseline SF was below or above 1000 µg/L. There were no significant differences between hemoglobin subgroups regarding baseline and treatment characteristics, except for transferrin saturation between male subgroups with SF above 1000 µg/L. Similar differences were observed when females with higher (≥138 g/L) baseline hemoglobin were compared with those with lower (baseline hemoglobin. Conclusion. Dividing C282Y-homozygous patients into just two subgroups according to the degree of baseline SF elevation may obscure important subgroup variations. PMID:26380265

  16. Porphyromonas endodontalis binds, reduces and grows on human hemoglobin.

    Zerr, M; Drake, D; Johnson, W; Cox, C D

    2001-08-01

    Porphyromonas endodontalis is a black-pigmented, obligate anaerobic rod-shaped bacterium implicated as playing a major role in endodontic infections. We have previously shown that P. endodontalis requires the porphyrin nucleus, preferably supplied as hemoglobin, as a growth supplement. The bacteria also actively transport free iron, although this activity does not support growth in the absence of a porphyrin source. The purpose of this study was to further investigate the binding and subsequent utilization of human hemoglobin by P. endodontalis. P. endodontalis binds hemoglobin and reduces the Fe(III) porphyrin, resulting in a steady accumulation of ferrous hemoglobin. Reduction of methemoglobin was similar to the extracellular reduction of nitrobluetetrazolium in the presence of oxidizable substrate. Turbidimetric and viable cell determinations showed that P. endodontalis grew when supplied only hemoglobin. Therefore, we conclude that hemoglobin appears to serve as a sole carbon and nitrogen source, and that these bacteria reduce extracellular compounds at the expense of oxidized substrates.

  17. Characterization of hemoglobin-benzo[a]pyrene adducts

    Haugen, D.A.; Myers, S.R.

    1987-01-01

    Cultures of Syrian hamster embryo (SHE) cells were supplemented with human Hb (0.2 mM heme) and [ 3 H]BP (1 μM). After a 24-h incubation, the medium was removed and subjected to cation-exchange liquid chromatography (CM-Sepharose) to resolve hemoglobins from serum proteins in the medium. The BP-treated Hb was subjected to analysis in each of three column chromatographic systems established for isolation and characterization of human hemoglobin and its genetic and post-translationally modified variants. Results demonstrate that hemoglobin-carcinogen adducts can be resolved from native hemoglobin by established conventional and high-performance liquid chromatographic procedures, suggesting the basis for development of general approaches for isolating and characterizing hemoglobin-carcinogen adducts. The results also suggest the basis for a model system in which adducts between carcinogens and human hemoglobin are formed in cultures of mammalian cells or tissues

  18. Studies on radiation induced changes in bovine hemoglobin type A

    Wdzieczak, J.; Duda, W.; Leyko, W.

    1978-01-01

    In this paper the structural and functional changes of gamma irradiated bovine hemoglobin are presented. Aqueous solutions/1%/of HbO 2 were irradiated in air with doses ranging from 1 to 4 Mrad. Isoelectric focusing indicated change of the charge of irradiated hemoglobin. The isoelectric point of hemoglobin was displaced towards more acid values with increasing doses, up from 1 Mrad. Fingerprint analysis and peptide column chromatography of irradiated hemoglobin demonstrated disturbances increasing with the dose. These changes were confirmed by amino acid analysis which showed that Cys, Met, Trp, His, Pro and Tyr residues were destroyed or modified following irradiation. At doses exceeding 1 Mrad the irradiated solutions of hemoglobin showed a decrease of heme-heme interaction and an increase of affinity for oxygen. Differences observed in oxygen-dissociation curves seem to be correlated with the radiation induced destruction of amino acid residues which are responsible for the functional properties of hemoglobin. (auth.)

  19. A review of variant hemoglobins interfering with hemoglobin A1c measurement.

    Little, Randie R; Roberts, William L

    2009-05-01

    Hemoglobin A1c (HbA1c) is used routinely to monitor long-term glycemic control in people with diabetes mellitus, as HbA1c is related directly to risks for diabetic complications. The accuracy of HbA1c methods can be affected adversely by the presence of hemoglobin (Hb) variants or elevated levels of fetal hemoglobin (HbF). The effect of each variant or elevated HbF must be examined with each specific method. The most common Hb variants worldwide are HbS, HbE, HbC, and HbD. All of these Hb variants have single amino acid substitutions in the Hb beta chain. HbF is the major hemoglobin during intrauterine life; by the end of the first year, HbF falls to values close to adult levels of approximately 1%. However, elevated HbF levels can occur in certain pathologic conditions or with hereditary persistence of fetal hemoglobin. In a series of publications over the past several years, the effects of these four most common Hb variants and elevated HbF have been described. There are clinically significant interferences with some methods for each of these variants. A summary is given showing which methods are affected by the presence of the heterozygous variants S, E, C, and D and elevated HbF. Methods are divided by type (immunoassay, ion-exchange high-performance liquid chromatography, boronate affinity, other) with an indication of whether the result is artificially increased or decreased by the presence of a Hb variant. Laboratorians should be aware of the limitations of their method with respect to these interferences. 2009 Diabetes Technology Society.

  20. Electronics

    2001-01-01

    International Acer Incorporated, Hsin Chu, Taiwan Aerospace Industrial Development Corporation, Taichung, Taiwan American Institute of Taiwan, Taipei, Taiwan...Singapore and Malaysia .5 - 4 - The largest market for semiconductor products is the high technology consumer electronics industry that consumes up...Singapore, and Malaysia . A new semiconductor facility costs around $3 billion to build and takes about two years to become operational

  1. Hemoglobin structural dynamics as monitored by resonance Raman spectroscopy

    Spiro, T.G.

    1981-01-01

    Resonance Raman spectra of the heme group are now understood at a level sufficient to provide a useful monitor of several heme structural features. Some porphyrin vibrational frequencies are sensitive to Fe oxidation state, or π-electron distribution, and give insight into the electronic structure of O 2 , CO and NO hemes. Others are sensitive to Fe spin-state, via the associated geometry variation, and provide an accurate index of the porphyrin core size. When examined during the photolysis of CO-hemoglobin via short laser pulses, these frequencies indicate that conversion from low- to h+gh-spin Fe 11 takes place within 30 ps of photolysis, presumably via intersystem-crossing in the excited state, but that the subsequent relaxation of the Fe atom out of the heme plane takes longer than 20 ns, probably because of restraint by the protein. Axial ligand modes have been identified for several heme derivatives. The Fe-imidazole frequency in deoxyhemoglobin is appreciably lowered in the T quaternary structure, as determined in both static and kinetic experiments, suggesting molecular tension or proximal imidazole H-bond weakening in the T state. (author)

  2. Evaluation of three electronic report processing systems for preparing hydrologic reports of the U.S Geological Survey, Water Resources Division

    Stiltner, G.J.

    1990-01-01

    In 1987, the Water Resources Division of the U.S. Geological Survey undertook three pilot projects to evaluate electronic report processing systems as a means to improve the quality and timeliness of reports pertaining to water resources investigations. The three projects selected for study included the use of the following configuration of software and hardware: Ventura Publisher software on an IBM model AT personal computer, PageMaker software on a Macintosh computer, and FrameMaker software on a Sun Microsystems workstation. The following assessment criteria were to be addressed in the pilot studies: The combined use of text, tables, and graphics; analysis of time; ease of learning; compatibility with the existing minicomputer system; and technical limitations. It was considered essential that the camera-ready copy produced be in a format suitable for publication. Visual improvement alone was not a consideration. This report consolidates and summarizes the findings of the electronic report processing pilot projects. Text and table files originating on the existing minicomputer system were successfully transformed to the electronic report processing systems in American Standard Code for Information Interchange (ASCII) format. Graphics prepared using a proprietary graphics software package were transferred to all the electronic report processing software through the use of Computer Graphic Metafiles. Graphics from other sources were entered into the systems by scanning paper images. Comparative analysis of time needed to process text and tables by the electronic report processing systems and by conventional methods indicated that, although more time is invested in creating the original page composition for an electronically processed report , substantial time is saved in producing subsequent reports because the format can be stored and re-used by electronic means as a template. Because of the more compact page layouts, costs of printing the reports were 15% to 25

  3. A thermodynamical measure of cooperativity: application to hemoglobin

    Jacchieri, S.G.; Ferreira, R.C.

    1984-01-01

    A comparative analysis of the heat requirements for dioxygen exchange is made for hemoglobin and myoglobin, the latter taken as the prototype of the vertebrate hemoglobin's ancestor. it is shown that cooperativity manifests itself also in terms of energy utilization. (Author) [pt

  4. Study of methyl bromide reactivity with human and mouse hemoglobin

    A study has been carried out on in-vitro reactivity of human and mouse hemoglobin spectrophotometrically at physiological pH, using different protein to reagent ratios. Hemoglobin side chains were modified with different concentrations of methyl bromide on agro-soil fumigant. To ascertain if the site of alkylation was the ...

  5. Biphasic oxidation of oxy-hemoglobin in bloodstains

    Bremmer, Rolf H.; de Bruin, Daniel M.; de Joode, Maarten; Buma, Wybren Jan; van Leeuwen, Ton G.; Aalders, Maurice C. G.

    2011-01-01

    In forensic science, age determination of bloodstains can be crucial in reconstructing crimes. Upon exiting the body, bloodstains transit from bright red to dark brown, which is attributed to oxidation of oxy-hemoglobin (HbO(2)) to met-hemoglobin (met-Hb) and hemichrome (HC). The fractions of

  6. Haptoglobin radioassay based on binding to solid-phase hemoglobin

    Hooper, D.C.; Reed, R.A.; Peacock, A.C.

    1979-01-01

    A specific and sensitive assay for haptoglobin based on binding to an easily prepred Sepharose-bound hemoglobin reagent is described. The assay is suitable for directly determining radiolabeled amino acid incorporation into haptoglobin in several liver cell systems in vitro and can be adapted to measure unlabeled free haptoglobin in plasma samples regardlss of the presence of the haptoglobin--hemoglobin complex

  7. Biphasic Oxidation of Oxy-Hemoglobin in Bloodstains

    Bremmer, R.H.; de Bruin, D.M.; de Joode, M.; Buma, W.J.; van Leeuwen, T.G.; Aalders, M.C.G.

    2011-01-01

    Background In forensic science, age determination of bloodstains can be crucial in reconstructing crimes. Upon exiting the body, bloodstains transit from bright red to dark brown, which is attributed to oxidation of oxy-hemoglobin (HbO2) to met-hemoglobin (met-Hb) and hemichrome (HC). The fractions

  8. 21 CFR 864.7400 - Hemoglobin A2 assay.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hemoglobin A2 assay. 864.7400 Section 864.7400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7400 Hemoglobin A2...

  9. 21 CFR 864.7455 - Fetal hemoglobin assay.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal hemoglobin assay. 864.7455 Section 864.7455 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7455 Fetal hemoglobin...

  10. 21 CFR 522.1125 - Hemoglobin glutamer-200 (bovine).

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Hemoglobin glutamer-200 (bovine). 522.1125 Section... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.1125 Hemoglobin glutamer-200 (bovine). (a) Specifications. Each 125 milliliter bag contains 13...

  11. Conformational changes in hemoglobin triggered by changing the iron charge

    Croci, S.; Achterhold, K.; Ortalli, I.; Parak, F. G.

    2008-01-01

    In this work the hemoglobin conformational changes induced by changing the iron charge have been studied and compared with Myoglobin. Moessbauer spectroscopy was used to follow the change of the iron conformation. In order to compare the conformational relaxation of hemoglobin and myoglobin, and to study a possible influence of the quaternary structure, an intermediate metastable state of hemoglobin has been created by low temperature X-ray irradiation of methemoglobin. The irradiation reduces the Fe(III) of the heme groups to Fe(II) Low Spin, where the water is still bound on the sixth coordination. Heating cycles performed at temperatures from 140 K to 200 K allow the molecules to overcome an activation energy barrier and to relax into a stable conformation such as deoxy-hemoglobin or carboxy-hemoglobin, if CO is present. Slightly different structures (conformational substates) reveal themselves as a distribution of energy barriers (ΔG). The distribution of the activation energy, for the decay of the Fe(II) Low Spin intermediate, has been fitted with a Gaussian. For comparison, published myoglobin data were re-analysed in the same way. The average energy value at characteristic temperature is very similar in case of myoglobin and hemoglobin. The larger Gaussian energy distribution for myoglobin with respect to hemoglobin shows that more conformational substates are available. This may be caused by a larger area exposed to water. In hemoglobin, part of the surface of the chains is not water accessible due to the quaternary structure.

  12. Radiation - induced changes in the optical properties of hemoglobin molecule

    Selim, N.S; El-Marakby, S.M.

    2009-01-01

    Adult male albino rats were exposed to different doses of gamma radiation from Cs-137 source. Hemoglobin samples were analyzed 24 hrs after irradiation. The UV-visible spectrum of hemoglobin molecule was measured in the range 200 to 700 nm. The overall spectrum of the hemoglobin molecule showed hypochromicity that increased with dose increase. To investigate the effect of radiation on the hemoglobin molecule, different parameters of the spectrum were calculated: molar absorption coefficient, absorption cross section, transition dipole moment , dipole length, the optical energy gap and activation energy for each characteristic peak. The obtained results revealed that the radiation effect can induce rearrangement of the transition dipole moments and change molecular energy levels of the hemoglobin molecule

  13. INTRINSIC REGULATION OF HEMOGLOBIN EXPRESSION BY VARIABLE SUBUNIT INTERFACE STRENGTHS

    Manning, James M.; Popowicz, Anthony M.; Padovan, Julio C.; Chait, Brian T.; Manning, Lois R.

    2012-01-01

    SUMMARY The expression of the six types of human hemoglobin subunits over time is currently considered to be regulated mainly by transcription factors that bind to upstream control regions of the gene (the “extrinsic” component of regulation). Here we describe how subunit pairing and further assembly to tetramers in the liganded state is influenced by the affinity of subunits for one another (the “intrinsic” component of regulation). The adult hemoglobin dimers have the strongest subunit interfaces and the embryonic hemoglobins are the weakest with fetal hemoglobins of intermediate strength, corresponding to the temporal order of their expression. These variable subunit binding strengths and the attenuating effects of acetylation contribute to the differences with which these hemoglobin types form functional O2-binding tetramers consistent with gene switching. PMID:22129306

  14. Electronic resources of the rare books and valuable editions department of the Central Scientific Library of the V.N. Karazin Kharkiv National University: open access for research

    І. К. Журавльова

    2014-12-01

    Full Text Available The article describes tasks that electronic collections of rare books fulfill: broad access for readers to rare and valuable editions providing, preservation of ensuring of the original. On the example of the electronic collection of the Central Scientific Library of the V.N. Karazin Kharkiv National University – «eScriptorium: electronic archive of rare books and manuscripts for research and education» the possibility of the full-text resources of the valuable editions using is shown. The principles of creation, structure, chronological frameworks, directions of adding the documents to the archive are represented. The perspectives of the project development are outlined as well as examples of the digital libraries of the European countries and Ukraine are provided, the actual task of preserving the originals of the rare books of the country is raised, the innovative approaches to serving users with electronic resources are considered. The evidences of cooperation of the Central Scientific Library of the V.N. Karazin Kharkiv National University with the largest world digital libraries: World Digital Library and Europeana are provided.

  15. The use of quality benchmarking in assessing web resources for the dermatology virtual branch library of the National electronic Library for Health (NeLH).

    Kamel Boulos, M N; Roudsari, A V; Gordon, C; Muir Gray, J A

    2001-01-01

    In 1998, the U.K. National Health Service Information for Health Strategy proposed the implementation of a National electronic Library for Health to provide clinicians, healthcare managers and planners, patients and the public with easy, round the clock access to high quality, up-to-date electronic information on health and healthcare. The Virtual Branch Libraries are among the most important components of the National electronic Library for Health. They aim at creating online knowledge based communities, each concerned with some specific clinical and other health-related topics. This study is about the envisaged Dermatology Virtual Branch Libraries of the National electronic Library for Health. It aims at selecting suitable dermatology Web resources for inclusion in the forthcoming Virtual Branch Libraries after establishing preliminary quality benchmarking rules for this task. Psoriasis, being a common dermatological condition, has been chosen as a starting point. Because quality is a principal concern of the National electronic Library for Health, the study includes a review of the major quality benchmarking systems available today for assessing health-related Web sites. The methodology of developing a quality benchmarking system has been also reviewed. Aided by metasearch Web tools, candidate resources were hand-selected in light of the reviewed benchmarking systems and specific criteria set by the authors. Over 90 professional and patient-oriented Web resources on psoriasis and dermatology in general are suggested for inclusion in the forthcoming Dermatology Virtual Branch Libraries. The idea of an all-in knowledge-hallmarking instrument for the National electronic Library for Health is also proposed based on the reviewed quality benchmarking systems. Skilled, methodical, organized human reviewing, selection and filtering based on well-defined quality appraisal criteria seems likely to be the key ingredient in the envisaged National electronic Library for

  16. Barriers to electronic access and delivery of educational information in resource constrained public schools: a case of Greater Tubatse Municipality

    Pholotho, T

    2016-05-01

    Full Text Available Information and Communication Technologies (ICTs) are capable of expanding access to quality education, educational resources and provide teachers with new skills. Nevertheless, a majority of rural public schools have limited ICTs, mainly due...

  17. Hemoglobin protein hollow shells fabricated through covalent layer-by-layer technique

    Duan Li; He Qiang; Yan Xuehai; Cui Yue; Wang Kewei; Li Junbai

    2007-01-01

    Hemoglobin (Hb) protein microcapsules held together by cross-linker, glutaraldehyde (GA), were successfully fabricated by covalent layer-by-layer (LbL) technique. The Schiff base reaction occurred on the colloid templates between the aldehyde groups of GA and free amino sites of Hb results in the formation of GA/Hb microcapsules after the removal of the templates. The structure of obtained monodisperse protein microcapsule was characterized by transmission electron microscopy (TEM) and confocal laser scanning microscopy (CLSM). The UV-Vis spectra measurements demonstrate the existence of Hb in the assembled capsules. Cyclic voltammetry (CV) and potential-controlled amperometric measurements (I-t curve) confirm that hemoglobin microcapsules after fabrication remain their heme electroactivity. Moreover, direct electron transfer process from protein to electrode surface was performed to detect the heme electrochemistry without using any mediator or promoter. The experiments of fluorescence recovery after photobleaching (FRAP) by CLSM demonstrate that the hemoglobin protein microcapsules have an improved permeability comparing to the conventional polyelectrolyte microcapsules

  18. Electronic Grey Literature in Accelerator Science and Its Allied Subjects : Selected Web Resources for Scientists and Engineers

    Rajendiran, P

    2006-01-01

    Grey literature Web resources in the field of accelerator science and its allied subjects are collected for the scientists and engineers of RRCAT (Raja Ramanna Centre for Advanced Technology). For definition purposes the different types of grey literature are described. The Web resources collected and compiled in this article (with an overview and link for each) specifically focus on technical reports, preprints or e-prints, which meet the main information needs of RRCAT users.

  19. Effect of Multiple Mutations in the Hemoglobin- and Hemoglobin-Haptoglobin-Binding Proteins, HgpA, HgpB, and HgpC, of Haemophilus influenzae Type b

    Morton, Daniel J.; Whitby, Paul W.; Jin, Hongfan; Ren, Zhen; Stull, Terrence L.

    1999-01-01

    Haemophilus influenzae requires heme for growth and can utilize hemoglobin and hemoglobin-haptoglobin as heme sources. We previously identified two hemoglobin- and hemoglobin-haptoglobin-binding proteins, HgpA and HgpB, in H. influenzae HI689. Insertional mutation of hgpA and hgpB, either singly or together, did not abrogate the ability to utilize or bind either hemoglobin or the hemoglobin-haptoglobin complex. A hemoglobin affinity purification method was used to isolate a protein of approxi...

  20. Diffusion coefficients of oxygen and hemoglobin as obtained simultaneously from photometric determination of the oxygenation of layers of hemoglobin solutions

    Spaan, J. A.; Kreuzer, F.; van Wely, F. K.

    1980-01-01

    The oxygenation of layers of deoxygenated hemoglobin solutions after a sudden exposure to a gas containing oxygen at a partial pressure P1 has been studied by a photometric method. Layer thicknesses varied between 50 and 250 micron, hemoglobin concentrations between 0.1 and 0.34kg/l, and oxygen

  1. Highly sensitive voltammetric biosensor for nitric oxide based on its high affinity with hemoglobin

    Fan Chunhai; Liu Xinjian; Pang Jiantao; Li Genxi; Scheer, Hugo

    2004-01-01

    Although heme protein-based, amperometric nitric oxide (NO) biosensors have been well documented in previous studies, most have been conducted in anaerobic conditions. Herein we report a novel hemoglobin-based NO biosensor that is not only very sensitive but also usable in air. The heme protein was entrapped in a sodium montmorillonite film, which was immobilized at a pyrolytic graphite electrode surface. Film-entrapped hemoglobin can directly exchange electrons with the electrode, and this process has proven to favor the catalytic reduction of oxygen. In addition, NO induced a cathodic potential shift of the catalytic reduction peak of oxygen. This potential shift was proportional to the logarithm of NO concentration ranging from 4.0 x 10 -11 to 5.0 x 10 -6 mol/L. The detection limit has been estimated to be 20 pM, approximately four orders lower than previously reported amperometric detectors

  2. Histopathologic Study Following Administration of Liposome-Encapsulated Hemoglobin in the Normovolemic Rat

    Rudolph, Alan

    1995-01-01

    ... bovine hemoglobin in the normovolemic rat. We have also examined the administration of the liposome vehicle, tetrameric bovine hemoglobin, and liposome encapsulated bovine hemoglobin that had been lyophilized with 300 mM trehalose...

  3. Genomic organization and evolution of the Atlantic salmon hemoglobin repertoire

    Phillips Ruth B

    2010-10-01

    Full Text Available Abstract Background The genomes of salmonids are considered pseudo-tetraploid undergoing reversion to a stable diploid state. Given the genome duplication and extensive biological data available for salmonids, they are excellent model organisms for studying comparative genomics, evolutionary processes, fates of duplicated genes and the genetic and physiological processes associated with complex behavioral phenotypes. The evolution of the tetrapod hemoglobin genes is well studied; however, little is known about the genomic organization and evolution of teleost hemoglobin genes, particularly those of salmonids. The Atlantic salmon serves as a representative salmonid species for genomics studies. Given the well documented role of hemoglobin in adaptation to varied environmental conditions as well as its use as a model protein for evolutionary analyses, an understanding of the genomic structure and organization of the Atlantic salmon α and β hemoglobin genes is of great interest. Results We identified four bacterial artificial chromosomes (BACs comprising two hemoglobin gene clusters spanning the entire α and β hemoglobin gene repertoire of the Atlantic salmon genome. Their chromosomal locations were established using fluorescence in situ hybridization (FISH analysis and linkage mapping, demonstrating that the two clusters are located on separate chromosomes. The BACs were sequenced and assembled into scaffolds, which were annotated for putatively functional and pseudogenized hemoglobin-like genes. This revealed that the tail-to-tail organization and alternating pattern of the α and β hemoglobin genes are well conserved in both clusters, as well as that the Atlantic salmon genome houses substantially more hemoglobin genes, including non-Bohr β globin genes, than the genomes of other teleosts that have been sequenced. Conclusions We suggest that the most parsimonious evolutionary path leading to the present organization of the Atlantic salmon

  4. Genomic organization and evolution of the Atlantic salmon hemoglobin repertoire

    2010-01-01

    Background The genomes of salmonids are considered pseudo-tetraploid undergoing reversion to a stable diploid state. Given the genome duplication and extensive biological data available for salmonids, they are excellent model organisms for studying comparative genomics, evolutionary processes, fates of duplicated genes and the genetic and physiological processes associated with complex behavioral phenotypes. The evolution of the tetrapod hemoglobin genes is well studied; however, little is known about the genomic organization and evolution of teleost hemoglobin genes, particularly those of salmonids. The Atlantic salmon serves as a representative salmonid species for genomics studies. Given the well documented role of hemoglobin in adaptation to varied environmental conditions as well as its use as a model protein for evolutionary analyses, an understanding of the genomic structure and organization of the Atlantic salmon α and β hemoglobin genes is of great interest. Results We identified four bacterial artificial chromosomes (BACs) comprising two hemoglobin gene clusters spanning the entire α and β hemoglobin gene repertoire of the Atlantic salmon genome. Their chromosomal locations were established using fluorescence in situ hybridization (FISH) analysis and linkage mapping, demonstrating that the two clusters are located on separate chromosomes. The BACs were sequenced and assembled into scaffolds, which were annotated for putatively functional and pseudogenized hemoglobin-like genes. This revealed that the tail-to-tail organization and alternating pattern of the α and β hemoglobin genes are well conserved in both clusters, as well as that the Atlantic salmon genome houses substantially more hemoglobin genes, including non-Bohr β globin genes, than the genomes of other teleosts that have been sequenced. Conclusions We suggest that the most parsimonious evolutionary path leading to the present organization of the Atlantic salmon hemoglobin genes involves

  5. Quantifying risk of penile prosthesis infection with elevated glycosylated hemoglobin.

    Wilson, S K; Carson, C C; Cleves, M A; Delk, J R

    1998-05-01

    Elevation of glycosylated hemoglobin above levels of 11.5 mg.% has been considered a contraindication to penile prosthesis implantation in diabetic patients. We determine the predictive value of glycosylated hemoglobin A1C in penile prosthesis infections in diabetic and nondiabetic patients to confirm or deny this prevalent opinion. We conducted a 2-year prospective study of 389 patients, including 114 diabetics, who underwent 3-piece penile prosthesis implantation. All patients had similar preoperative preparation without regard to diabetic status, control or glycosylated hemoglobin A1C level. Risk of infection was statistically analyzed for diabetics versus nondiabetics, glycosylated hemoglobin A1C values above and below 11.5 mg.%, insulin dependent versus oral medication diabetics, and fasting blood sugars above and below 180 mg.%. Prosthesis infections developed in 10 diabetics (8.7%) and 11 nondiabetics (4.0%). No increased infection rate was observed in diabetics with high fasting sugars or diabetics on insulin. There was no statistically significant increased infection risk with increased levels of glycosylated hemoglobin A1C among all patients or among only the diabetics. In fact, there was no meaningful difference in the median or mean level of glycosylated hemoglobin A1C in the infected and noninfected patients regardless of diabetes. Use of glycosylated hemoglobin A1C values to identify and exclude surgical candidates with increased risk of infections is not proved by this study. Elevation of fasting sugar or insulin dependence also does not increase risk of infection in diabetics undergoing prosthesis implantation.

  6. Postoperative hemoglobin level in patients with femoral neck fracture.

    Nagra, Navraj S; Van Popta, Dmitri; Whiteside, Sigrid; Holt, Edward M

    2016-01-01

    The aim of this study was to analyze the changes of hemoglobin levels in patients undergoing fixation for femoral neck fracture. Peroperative hemoglobin levels of patients who underwent either dynamic hip screw (DHS) fixation (n=74; mean age: 80 years) or hip hemiarthroplasty (n=104; mean age: 84 years) for femoral neck fracture was monitored. There was a statistically and clinically significant mean drop of 31.1 g/L between the preoperative (D0) and postoperative Day 5 Hb levels (pmeasurement, DHS patients had lower hemoglobin values over hemiarthroplasty patients (p=0.046). The decrease in hemoglobin in the first 24-hour postoperative period (D0 to Day 1) is an underestimation of the ultimate lowest value in hemoglobin found at Day 2. Relying on the Day 1 hemoglobin level could be detrimental to patient care. We propose a method of predicting patients likely to be transfused and recommend a protocol for patients undergoing femoral neck fracture surgery to standardize postoperative hemoglobin monitoring.

  7. Expression of fully functional tetrameric human hemoglobin in Escherichia coli

    Hoffman, S.J.; Looker, D.L.; Roehrich, J.M.; Cozart, P.E.; Durfee, S.L.; Tedesco, J.L.; Stetler, G.L.

    1990-01-01

    Synthesis genes encoding the human α- and β-globin polypeptides have been expressed from a single operon in Escherichia coli. The α- and β-globin polypeptides associate into soluble tetramers, incorporate heme, and accumulate to >5% of the total cellular protein. Purified recombinant hemoglobin has the correct stoichiometry of α- and β-globin chains and contains a full complement of heme. Each globin chain also contains an additional methionine as an extension to the amino terminus. The recombinant hemoglobin has a C 4 reversed-phase HPLC profile essentially identical to that of human hemoglobin A 0 and comigrates with hemoglobin A 0 on SDS/PAGE. The visible spectrum and oxygen affinity are similar to that of native human hemoglobin A 0 . The authors have also expressed the α- and β-globin genes separately and found that the expression of the α-globin gene alone results in a marked decrease in the accumulation of α-globin in the cell. Separate expression of the β-globin gene results in high levels of insoluble β-globin. These observations suggest that the presence of α- and β-globin in the same cell stabilizes α-globin and aids the correct folding of β-globin. This system provides a simple method for expressing large quantities of recombinant hemoglobin and allows facile manipulation of the genes encoding hemoglobin to produce functionally altered forms of this protein

  8. Using the MWC model to describe heterotropic interactions in hemoglobin

    Rapp, Olga

    2017-01-01

    Hemoglobin is a classical model allosteric protein. Research on hemoglobin parallels the development of key cooperativity and allostery concepts, such as the ‘all-or-none’ Hill formalism, the stepwise Adair binding formulation and the concerted Monod-Wymann-Changuex (MWC) allosteric model. While it is clear that the MWC model adequately describes the cooperative binding of oxygen to hemoglobin, rationalizing the effects of H+, CO2 or organophosphate ligands on hemoglobin-oxygen saturation using the same model remains controversial. According to the MWC model, allosteric ligands exert their effect on protein function by modulating the quaternary conformational transition of the protein. However, data fitting analysis of hemoglobin oxygen saturation curves in the presence or absence of inhibitory ligands persistently revealed effects on both relative oxygen affinity (c) and conformational changes (L), elementary MWC parameters. The recent realization that data fitting analysis using the traditional MWC model equation may not provide reliable estimates for L and c thus calls for a re-examination of previous data using alternative fitting strategies. In the current manuscript, we present two simple strategies for obtaining reliable estimates for MWC mechanistic parameters of hemoglobin steady-state saturation curves in cases of both evolutionary and physiological variations. Our results suggest that the simple MWC model provides a reasonable description that can also account for heterotropic interactions in hemoglobin. The results, moreover, offer a general roadmap for successful data fitting analysis using the MWC model. PMID:28793329

  9. Individualized anemia management reduces hemoglobin variability in hemodialysis patients.

    Gaweda, Adam E; Aronoff, George R; Jacobs, Alfred A; Rai, Shesh N; Brier, Michael E

    2014-01-01

    One-size-fits-all protocol-based approaches to anemia management with erythropoiesis-stimulating agents (ESAs) may result in undesired patterns of hemoglobin variability. In this single-center, double-blind, randomized controlled trial, we tested the hypothesis that individualized dosing of ESA improves hemoglobin variability over a standard population-based approach. We enrolled 62 hemodialysis patients and followed them over a 12-month period. Patients were randomly assigned to receive ESA doses guided by the Smart Anemia Manager algorithm (treatment) or by a standard protocol (control). Dose recommendations, performed on a monthly basis, were validated by an expert physician anemia manager. The primary outcome was the percentage of hemoglobin concentrations between 10 and 12 g/dl over the follow-up period. A total of 258 of 356 (72.5%) hemoglobin concentrations were between 10 and 12 g/dl in the treatment group, compared with 208 of 336 (61.9%) in the control group; 42 (11.8%) hemoglobin concentrations were hemoglobin concentrations were >12 g/dl in the treatment group compared with 46 (13.4%) in the control group. The median ESA dosage per patient was 2000 IU/wk in both groups. Five participants received 6 transfusions (21 U) in the treatment group, compared with 8 participants and 13 transfusions (31 U) in the control group. These results suggest that individualized ESA dosing decreases total hemoglobin variability compared with a population protocol-based approach. As hemoglobin levels are declining in hemodialysis patients, decreasing hemoglobin variability may help reduce the risk of transfusions in this population.

  10. Relationship between maternal hemoglobin and perinatal outcome

    Bakhtiar, U.J.; Khan, Y.; Nisar, R.

    2007-01-01

    To Study the Relationship between Maternal Hemoglobin and Perinatal outcome in a cohort of 860 pregnant women and to highlight the importance of antenatal care regarding maternal health and fetal outcome. All Singleton pregnancies delivering at Pakistan Railway Hospital Rawalpindi from January 2004 to December 2005 that fulfilled the required criteria were included. Out of the 860 patients, 402 were anemic (<11gm/dl) and 458 were non anemic. Perinatal outcome included preterm delivery, low birth weight, intrauterine growth retardation, perinatal death, low apgr scores and intrauterine fetal deaths. Risk of preterm and Low birth weight among anemic women was 3.4 and 1.8 times more than non anaemic women. The neonates of anemic woman also had 1.7 times increased risk of having low apgr scores at 1 min. Among anemic women there was 2.2 times greater risk of intrauterine fetal death than the non-anemic women. Regular antenatal care from first trimester has a vital role in assessing and managing maternal anemia timely and it directly affects the perinatal outcome. The patients with anemia have also higher risk of having low birth weight, preterm births and intra uterine fetal death. (author)

  11. Noninvasive hemoglobin measurement using dynamic spectrum

    Yi, Xiaoqing; Li, Gang; Lin, Ling

    2017-08-01

    Spectroscopy methods for noninvasive hemoglobin (Hgb) measurement are interfered by individual difference and particular weak signal. In order to address these problems, we have put forward a series of improvement methods based on dynamic spectrum (DS), including instrument design, spectrum extraction algorithm, and modeling approach. The instrument adopts light sources composed of eight laser diodes with the wavelength range from 600 nm to 1100 nm and records photoplethysmography signals at eight wavelengths synchronously. In order to simplify the optical design, we modulate the light sources with orthogonal square waves and design the corresponding demodulation algorithm, instead of adopting a beam-splitting system. A newly designed algorithm named difference accumulation has been proved to be effective in improving the accuracy of dynamic spectrum extraction. 220 subjects are involved in the clinical experiment. An extreme learning machine calibration model between the DS data and the Hgb levels is established. Correlation coefficient and root-mean-square error of prediction sets are 0.8645 and 8.48 g/l, respectively. The results indicate that the Hgb level can be derived by this approach noninvasively with acceptable precision and accuracy. It is expected to achieve a clinic application in the future.

  12. Evans Syndrome Complicated by Intratubular Hemoglobin Cast Nephropathy

    Iván González

    2017-01-01

    Full Text Available Evans syndrome (ES is a rare autoimmune disorder whose exact pathophysiology is unknown. It is characterized by the simultaneous or subsequent development of autoimmune hemolytic anemia (AIHA and immune thrombocytopenia (ITP. Intravascular hemolysis, with hemoglobinemia, is known to produce acute kidney injury; however, the development of intratubular hemoglobin casts (hemoglobin cast nephropathy in the setting of acute hemolysis is uncommon. Likewise, the association of ES and acute renal failure is equally uncommon. We present a case of a 7-year-old girl with ES who developed acute kidney injury in the setting of intravascular hemolysis and had widespread intratubular hemoglobin casts.

  13. Biophysical basis of hypoxic radioprotection by deoxygenated dextran-hemoglobin

    Wong, J.T.; Hill, R.P.

    1986-01-01

    Perfusion with deoxygenated dextran-hemoglobin provides an effective method for inducing hypoxic radioprotection of normal tissues during radiation treatment of tumors. In this study, the dependence of P50, the half-saturation pressure of oxygen binding to dextran-hemoglobin, was analyzed as a function of solution temperature and pH. The variation of attainable radioprotection with P50, and with the amount of collateral blood entering into the perfused region, was calculated. Upon perfusion of canine gracilis muscle with deoxygenated dextran-hemoglobin, a rapid onset of extensive venous hypoxia was observed

  14. Symbiotic and nonsymbiotic hemoglobin genes of Casuarina glauca

    Jacobsen-Lyon, K; Jensen, Erik Østergaard; Jørgensen, Jan-Elo

    1995-01-01

    Casuarina glauca has a gene encoding hemoglobin (cashb-nonsym). This gene is expressed in a number of plant tissues. Casuarina also has a second family of hemoglobin genes (cashb-sym) expressed at a high level in the nodules that Casuarina forms in a nitrogen-fixing symbiosis with the actinomycete...... of the Casuarina gene. The finding that the nonsymbiotic Casuarina gene is also correctly expressed in L. corniculatus suggests to us that a comparable non-symbiotic hemoglobin gene will be found in legume species. Udgivelsesdato: 1995-Feb...

  15. Clinician‐selected Electronic Information Resources do not Guarantee Accuracy in Answering Primary Care Physicians’ Information Needs. A review of: McKibbon, K. Ann, and Douglas B. Fridsma. “Effectiveness of Clinician‐selected Electronic Information Resources for Answering Primary Care Physicians’ Information Needs.” Journal of the American Medical Informatics Association 13.6 (2006: 653‐9.

    Martha Ingrid Preddie

    2008-03-01

    Full Text Available Objective – To determine if electronic information resources selected by primary care physicians improve their ability to answer simulated clinical questions.Design – An observational study utilizing hour‐long interviews and think‐aloud protocols.Setting – The offices and clinics of primary care physicians in Canada and the United States.Subjects – Twenty‐five primary care physicians of whom 4 were women, 17 were from Canada, 22 were family physicians,and 24 were board certified.Methods – Participants provided responses to 23 multiple‐choice questions. Each physician then chose two questions and looked for the answers utilizing information resources of their own choice. The search processes, chosen resources and search times were noted. These were analyzed along with data on the accuracy of the answers and certainties related to the answer to each clinical question prior to the search.Main results – Twenty‐three physicians sought answers to 46 simulated clinical questions. Utilizing only electronic information resources, physicians spent a mean of 13.0 (SD 5.5 minutes searching for answers to the questions, an average of 7.3(SD 4.0 minutes for the first question and 5.8 (SD 2.2 minutes to answer the second question. On average, 1.8 resources were utilized per question. Resources that summarized information, such as the Cochrane Database of Systematic Reviews, UpToDate and Clinical Evidence, were favored 39.2% of the time, MEDLINE (Ovid and PubMed 35.7%, and Internet resources including Google 22.6%. Almost 50% of the search and retrieval strategies were keyword‐based, while MeSH, subheadings and limiting were used less frequently. On average, before searching physicians answered 10 of 23 (43.5% questions accurately. For questions that were searched using clinician‐selected electronic resources, 18 (39.1% of the 46 answers were accurate before searching, while 19 (42.1% were accurate after searching. The difference of

  16. Self-Paced Interactive Multimedia Courseware: A Learning Support Resource for Enhancing Electronic Theses and Dissertations Development

    Essel, Harry Barton; Osei-Poku, Patrick; Tachie-Menson, Akosua; Opoku-Asare, Nana Afia

    2016-01-01

    Submission of Electronic Theses and Dissertations (ETDs) by postgraduate students has become a common phenomenon in learning environments globally. The purpose of ETDs is to train postgraduate students as knowledge workers in online publishing and also extend their skills beyond word processing. The challenge however, is that many postgraduate…

  17. Web Accessibility Issues for Higher & Further Education. EDNER (Formative Evaluation of the Distributed National Electronic Resource) Project. Issues Paper.

    Manchester Metropolitan Univ. (England).

    This issues paper, sixth in a series of eight, is intended to distill formative evaluation questions on topics that are central to the development of the higher and further education information environment in the United Kingdom. In undertaking formative evaluation studies, the Formative Evaluation of the Distributed National Electronic Resource…

  18. Analyzing the Academic Research Trends by Using University Digital Resources: A Bibliometric Study of Electronic Commerce in China

    Fatima, Anam; Abbas, Asad; Ming, Wan; Zaheer, Ahmad Nawaz; Akhtar, Masood-ul-Hassan

    2017-01-01

    Technology plays a vital role in every field of life especially in business and education. Electronic commerce (EC) begins in the year of 1991 right after internet was introduced for commercial use. It is known to be the 12th five years' plan (2011 to 2015) of Chinese Ministry of Industry and Information Technology. The main "objective"…

  19. Green Supply Chain Collaboration for Fashionable Consumer Electronics Products under Third-Party Power Intervention—A Resource Dependence Perspective

    Jiuh-Biing Sheu

    2014-01-01

    Under third-party power intervention (TPPI), which increases uncertainty in task environments, complex channel power interplays and restructuring are indispensable among green supply chain members as they move toward sustainable collaborative relationships for increased viability and competitive advantage. From the resource dependence perspective, this work presents a novel conceptual model to investigate the influence of political and social power on channel power restructuring and induced ...

  20. Amperometric biosensor for hydrogen peroxide based on hemoglobin entrapped in titania sol-gel film

    Yu Jiuhong; Ju Huangxian

    2003-01-01

    Hemoglobin (Hb) was entrapped in a titania sol-gel matrix and used as a mimetic peroxidase to construct a novel amperometric biosensor for hydrogen peroxide. The Hb entrapped titania sol-gel film was obtained with a vapor deposition method, which simplified the traditional sol-gel process for protein immobilization. The morphologies of both titania sol-gel and the Hb films were characterized using scanning electron microscopy (SEM) and proved to be chemically clean, porous, homogeneous. This matrix provided a biocompatible microenvironment for retaining the native structure and activity of the entrapped Hb and a very low mass transport barrier to the substrates. H 2 O 2 could be reduced by the catalysis of the entrapped hemoglobin at -300 mV without any mediator. The reagentless H 2 O 2 sensor exhibited a fast response (less than 5 s) and sensitivity as high as 1.29 mA mM -1 cm -2 . The linear range for H 2 O 2 determination was from 5.0x10 -7 to 5.4x10 -5 M with a detection limit of 1.2x10 -7 M. The apparent Michaelis-Menten constant of the encapsulated hemoglobin was calculated to be 0.18±0.02 mM. The stability of the biosensor was also evaluated

  1. Nanomolar detection of methylparaben by a cost-effective hemoglobin-based biosensor

    Hajian, A., E-mail: ali.hajian@fmf.uni-freiburg.de [Freiburg Materials Research Center, FMF, University of Freiburg, Stefan-Meier-Str.21, 79104 Freiburg (Germany); Laboratory for Sensors, Department of Microsystems Engineering, IMTEK, University of Freiburg, 79110 Freiburg (Germany); Ghodsi, J.; Afraz, A. [Department of Physical Chemistry, Faculty of Chemistry, Bu-Ali Sina University, 65174, Hamedan (Iran, Islamic Republic of); Yurchenko, O. [Freiburg Materials Research Center, FMF, University of Freiburg, Stefan-Meier-Str.21, 79104 Freiburg (Germany); Urban, G. [Freiburg Materials Research Center, FMF, University of Freiburg, Stefan-Meier-Str.21, 79104 Freiburg (Germany); Laboratory for Sensors, Department of Microsystems Engineering, IMTEK, University of Freiburg, 79110 Freiburg (Germany)

    2016-12-01

    This work describes the development of a new biosensor for methylparaben determination using electrocatalytic properties of hemoglobin in the presence of hydrogen peroxide. The voltammetric oxidation of methylparaben by the proposed biosensor in phosphate buffer (pH = 7.0), a physiological pH, was studied and it was confirmed that methylparaben undergoes a one electron-one proton reaction in a diffusion-controlled process. The biosensor was fabricated by carbon paste electrode modified with hemoglobin and multiwalled carbon nanotube. Based on the excellent electrochemical properties of the modified electrode, a sensitive voltammetric method was used for determination of methylparaben within a linear range from 0.1 to 13 μmol L{sup −1} and detection limit of 25 nmol L{sup −1}. The developed biosensor possessed accurate and rapid response to methylparaben and showed good sensitivity, stability, and repeatability. Finally, the applicability of the proposed biosensor was verified by methylparaben evaluation in various real samples. - Highlights: • A new methylparaben biosensor was constructed by modification of carbon paste electrode with hemoglobin and MWCNTs. • The electrochemical properties of the modified electrode and electrochemical behavior of the methylparaben on the electrode surface were studied. • The response of modified GCE was analyzed by voltammetry technique (CV and DPV). • The electrode was used to the determination of methylparaben in real samples • The performance of the fabricated biosensor was satisfactorily compared to the previously reported electrochemical sensors for methylparaben determination.

  2. Direct Electrochemistry of Hemoglobin at a Graphene Gold Nanoparticle Composite Film for Nitric Oxide Biosensing

    Guang-Chao Zhao

    2013-06-01

    Full Text Available A simple two-step method was employed for preparing nano-sized gold nanoparticles-graphene composite to construct a GNPs-GR-SDS modified electrode. Hemoglobin (Hb was successfully immobilized on the surface of a basal plane graphite (BPG electrode through a simple dropping technique. Direct electrochemistry and electrocatalysis of the hemoglobin-modified electrode was investigated. The as-prepared composites showed an obvious promotion of the direct electro-transfer between hemoglobin and the electrode. A couple of well-defined and quasi-reversible Hb CV peaks can be observed in a phosphate buffer solution (pH 7.0. The separation of anodic and cathodic peak potentials is 81 mV, indicating a fast electron transfer reaction. The experimental results also clarified that the immobilized Hb retained its biological activity for the catalysis toward NO. The biosensor showed high sensitivity and fast response upon the addition of NO, under the conditions of pH 7.0, potential ‒0.82 V. The time to reach the stable-state current was less than 3 s, and the linear response range of NO was 0.72–7.92 μM, with a correlation coefficient of 0.9991.

  3. Nanomolar detection of methylparaben by a cost-effective hemoglobin-based biosensor

    Hajian, A.; Ghodsi, J.; Afraz, A.; Yurchenko, O.; Urban, G.

    2016-01-01

    This work describes the development of a new biosensor for methylparaben determination using electrocatalytic properties of hemoglobin in the presence of hydrogen peroxide. The voltammetric oxidation of methylparaben by the proposed biosensor in phosphate buffer (pH = 7.0), a physiological pH, was studied and it was confirmed that methylparaben undergoes a one electron-one proton reaction in a diffusion-controlled process. The biosensor was fabricated by carbon paste electrode modified with hemoglobin and multiwalled carbon nanotube. Based on the excellent electrochemical properties of the modified electrode, a sensitive voltammetric method was used for determination of methylparaben within a linear range from 0.1 to 13 μmol L −1 and detection limit of 25 nmol L −1 . The developed biosensor possessed accurate and rapid response to methylparaben and showed good sensitivity, stability, and repeatability. Finally, the applicability of the proposed biosensor was verified by methylparaben evaluation in various real samples. - Highlights: • A new methylparaben biosensor was constructed by modification of carbon paste electrode with hemoglobin and MWCNTs. • The electrochemical properties of the modified electrode and electrochemical behavior of the methylparaben on the electrode surface were studied. • The response of modified GCE was analyzed by voltammetry technique (CV and DPV). • The electrode was used to the determination of methylparaben in real samples • The performance of the fabricated biosensor was satisfactorily compared to the previously reported electrochemical sensors for methylparaben determination.

  4. Ligand exchange reactions of the heme group in hemoglobin and myoglobin as studied by pulse radiolysis

    Raap, I.A.

    1978-01-01

    In this thesis, the kinetic aspects of the ligand exchange reactions of hemoglobin are studied using the pulse radiolysis technique, in particular, the reactions of hydrated electrons with methemoglobin. A hitherto unobserved transient state of the heme group is observed which appears immediately after the rapid reduction process. The absorption spectrum of this new species has the characteristics of a ferrous low-spin state and can therefore be ascribed to the formation of a hemochrome non-equilibrium state. The subsequent relaxation of this intermediate structure into a deoxy-conformation is dependent on the amount of proton activity in the solution and on the presence of organic and inorganic phosphate anions. The final absorption spectrum of the heme group is shown to correspond to a ferrous high-spin state in the relaxed quaternary conformation. This is in agreement with the kinetics observen the binding of carbon monoxide and oxygen to partially reduced methemoglobin. At reduction degrees of methemoglobin as well as of valncy 8ybrids where there is an important contribution from species with two reduced subunits, the binding of carbon monoxide to hemoglobin occurs with on-rate constants characteristic for the tensed quaternary conformation. It is argued that this conformational change of hemoglobin (the R-to-T transition) takes place very rapidly, which suggests the participation of an activated relaxed conformation. In addition, it is found that there is a distinct heterogeneity in the binding of oxygen to partially reduced methemoglobin even at low degrees of reduction

  5. 21 CFR 866.5470 - Hemoglobin immunological test system.

    2010-04-01

    .... Measurements of free hemoglobin aid in the diagnosis of various hematologic disorders, such as sickle cell... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  6. A nanocluster-based fluorescent sensor for sensitive hemoglobin detection.

    Yang, Dongqin; Meng, Huijie; Tu, Yifeng; Yan, Jilin

    2017-08-01

    In this report, a fluorescence sensor for sensitive detection of hemoglobin was developed. Gold nanoclusters were first synthesized with bovine serum albumin. It was found that both hydrogen peroxide and hemoglobin could weakly quench the fluorescence from the gold nanoclusters, but when these two were applied onto the nanolcusters simultaneously, a much improved quenching was resulted. This enhancing effect was proved to come from the catalytic generation of hydroxyl radical by hemoglobin. Under an optimized condition, the quenching linearly related to the concentration of hemoglobin in the range of 1-250nM, and a limit of detection as low as 0.36nM could be obtained. This provided a sensitive means for the quantification of Hb. The sensor was then successfully applied for blood analyses with simple sample pretreatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Novel subunit structure observed for noncooperative hemoglobin from Urechis caupo.

    Kolatkar, P R; Meador, W E; Stanfield, R L; Hackert, M L

    1988-03-05

    Tetrameric hemoglobin from the "fat innkeeper" worm Urechis caupo possesses a novel subunit arrangement having an "inside out" quaternary structure in that the G/H helices are located on the outer surface of the tetramer. A 5-A resolution crystal structure reveals that although the individual subunits are beta-like, having a distinct D helix and the general myoglobin fold, the subunit contacts are very different from those previously observed for hemoglobins. Furthermore, the hemoglobin from U. caupo is also quite different from the unusual hemoglobin tetramer from clam which also has its G/H helices on the outer surface but with the hemes in close proximity through E-F helical contacts (Royer, W. E., Jr., Love, W. E., and Fenderson, F. F. (1985) Nature 316, 277-280).

  8. The influence of socioeconomic status on the hemoglobin level and ...

    Conclusion: Poor socioeconomic status has an adverse effect on the nutritional status and hemoglobin of SCA patients. ... Date of Acceptance: 15-Mar-2011 ..... This study was designed to determine the relationship .... mobiles and devices.

  9. Hemoglobin as a factor in the control of tumor oxygenation

    Hirst, D.G.

    1987-01-01

    The concentration of hemoglobin in the blood has been shown to have a market effect on the radiosensitivity of human and animal tumors. Experimental studies in mice indicate that radiosensitivity is influenced by a change in the hemoglobin level rather than by the absolute concentration. This dependence may be exploited to therapeutic advantage. Recent studies of hemoglobin/oxygen affinity have shown that the concentration of 2,3 diphosphoglycerate (2,3 DPG) affects tumor sensitivity to X-rays. Increased 2,3 DPG levels increase radiosensitivity in several mouse tumors. The time dependence of this effect remains to be established. The effective application of these effects in man may depend on the development of drugs which produce changes in hemoglobin affinity without the need for blood transfusions. Several drugs are currently being investigated

  10. Manipulation of hemoglobin expression affects Arabidopsis shoot organogenesis

    Wang, Yaping; Elhiti, Mohamed; Hebelstrup, Kim

    2011-01-01

    Over the past few years non-symbiotic plant hemoglobins have been described in a variety of plant species where they fulfill several functions ranging from detoxification processes to basic aspects of plant growth and post-embryonic development. To date no information is available on the role...... of hemoglobins during invitro morphogenesis. Shoot organogenesis was induced in Arabidopsis lines constitutively expressing class 1, 2 and 3 hemoglobins (GLB1, 2 and 3) and lines in which the respective genes were either downregulated by RNAi (GLB1) or knocked out (GLB2 and GLB3). The process was executed......, 15, and 16), feed-back repressors of the cytokinin pathway, was repressed in both hemoglobin over-expressors whereas that of several Type-B ARRs (ARR2, 12, and 13), transcription activators of cytokinin-responsive genes, was induced. Such changes enhanced the sensitivity of the root explants...

  11. Lower versus Higher Hemoglobin Threshold for Transfusion in Septic Shock

    Holst, Lars B; Haase, Nicolai; Wetterslev, Jørn

    2014-01-01

    BACKGROUND: Blood transfusions are frequently given to patients with septic shock. However, the benefits and harms of different hemoglobin thresholds for transfusion have not been established. METHODS: In this multicenter, parallel-group trial, we randomly assigned patients in the intensive care...... unit (ICU) who had septic shock and a hemoglobin concentration of 9 g per deciliter or less to receive 1 unit of leukoreduced red cells when the hemoglobin level was 7 g per deciliter or less (lower threshold) or when the level was 9 g per deciliter or less (higher threshold) during the ICU stay...... were similar in the two intervention groups. CONCLUSIONS: Among patients with septic shock, mortality at 90 days and rates of ischemic events and use of life support were similar among those assigned to blood transfusion at a higher hemoglobin threshold and those assigned to blood transfusion...

  12. Direct electrochemistry of hemoglobin entrapped in dextran film on ...

    Administrator

    28. Li et al used single- walled carbon nanotube (SWCNT) and 1-hexyl-3- ... Electrochemistry of dextran/hemoglobin/carbon ionic liquid electrode. 273. 2.4 Procedures ..... used for the construction of H2O2 biosensor. Acknowledgement.

  13. Temperature-dependent enthalpy of oxygenation in Antarctic fish hemoglobins

    Fago, A.; Wells, R.M.G.; Weber, Roy E.

    1997-01-01

    The effect of temperature on the oxygen-binding properties of the hemoglobins of three cold-adapted Antarctic fish species, Dissostichus mawsoni, Pagothenia borchgrevinki and Trematomus, sp., has been investigated under different pH values and buffer conditions. A clear non linear van't Hoff plot...... (logP(50) vs 1/T) of D. mawsoni hemoglobin indicates that the enthalpy of oxygenation (slope of the plot) is temperature dependent and that at high temperatures oxygen-binding becomes less exothermic. Nearly linear relationships were found in the hemoglobins of the other two species. The data were...... oxygen binding. The degree of the temperature dependence of the heat of oxygenation observed in these hemoglobins seems to reflect the differences in their allosteric effects rather than a specific molecular adaptation to low temperatures. Moreover, this study indicates that the disagreement between...

  14. Receptor targeting of hemoglobin mediated by the haptoglobins

    Nielsen, Marianne Jensby; Moestrup, Søren Kragh

    2009-01-01

    Haptoglobin, the haptoglobin-hemoglobin receptor CD163, and the heme oxygenase-1 are proteins with a well-established function in the clearance and metabolism of "free" hemoglobin released during intravascular hemolysis. This scavenging system counteracts the potentially harmful oxidative and NO......-scavenging effects associated with "free" hemoglobin, and, furthermore, elicits an anti-inflammatory response. In the late primate evolution, haptoglobin variants with distinct functions have arisen, including haptoglobin polymers and the haptoglobin-related protein. The latter associates with a subspecies of high......-density lipoprotein (HDL) particles playing a crucial role in the innate immunity against certain trypanosome parasites. Recent studies have elucidated this fairly sophisticated immune defense mechanism that takes advantage of a trypanosomal haptoglobin-hemoglobin receptor evolved to supply the parasite with heme...

  15. Effects of thyroid status on glycated hemoglobin

    Rana Bhattacharjee

    2017-01-01

    Full Text Available Introduction: Glycated hemoglobin (HbA1c can be altered in different conditions. We hypothesize that HbA1c levels may change due to altered thyroid status, possibly due to changes in red blood cell (RBC turnover. Objectives: The objective of this study was to determine the effects of altered thyroid status on HbA1c levels in individuals without diabetes, with overt hyper- and hypo-thyroidism, and if present, whether such changes in HbA1c are reversed after achieving euthyroid state. Methods: Euglycemic individuals with overt hypo- or hyper-thyroidism were selected. Age- and sex-matched controls were recruited. Baseline HbA1c and reticulocyte counts (for estimation of RBC turnover were estimated in all the patients and compared. Thereafter, stable euthyroidism was achieved in a randomly selected subgroup and HbA1c and reticulocyte count was reassessed. HbA1c values and reticulocyte counts were compared with baseline in both the groups. Results: Hb A1c in patients initially selected was found to be significantly higher in hypothyroid group. HbA1c values in hyperthyroid patients were not significantly different from controls. HbA1c reduction and rise in reticulocyte count were significant in hypothyroid group following treatment without significant change in glucose level. Hb A1c did not change significantly following treatment in hyperthyroid group. The reticulocyte count, however, decreased significantly. Conclusion: Baseline HbA1c levels were found to be significantly higher in hypothyroid patients, which reduced significantly after achievement of euthyroidism without any change in glucose levels. Significant baseline or posttreatment change was not observed in hyperthyroid patients. Our study suggests that we should be cautious while interpreting HbA1c data in patients with hypothyroidism.

  16. Oxygen binding to partially nitrosylated hemoglobin.

    Fago, Angela; Crumbliss, Alvin L; Hendrich, Michael P; Pearce, Linda L; Peterson, Jim; Henkens, Robert; Bonaventura, Celia

    2013-09-01

    Reactions of nitric oxide (NO) with hemoglobin (Hb) are important elements in protection against nitrosative damage. NO in the vasculature is depleted by the oxidative reaction with oxy Hb or by binding to deoxy Hb to generate partially nitrosylated Hb (Hb-NO). Many aspects of the formation and persistence of Hb-NO are yet to be clarified. In this study, we used a combination of EPR and visible absorption spectroscopy to investigate the interactions of partially nitrosylated Hb with O2. Partially nitrosylated Hb samples had predominantly hexacoordinate NO-heme geometry and resisted oxidation when exposed to O2 in the absence of anionic allosteric effectors. Faster oxidation occurred in the presence of 2,3-diphosphoglycerate (DPG) or inositol hexaphosphate (IHP), where the NO-heme derivatives had higher levels of pentacoordinate heme geometry. The anion-dependence of the NO-heme geometry also affected O2 binding equilibria. O2-binding curves of partially nitrosylated Hb in the absence of anions were left-shifted at low saturations, indicating destabilization of the low O2 affinity T-state of the Hb by increasing percentages of NO-heme, much as occurs with increasing levels of CO-heme. Samples containing IHP showed small decreases in O2 affinity, indicating shifts toward the low-affinity T-state and formation of inert α-NO/β-met tetramers. Most remarkably, O2-equilibria in the presence of the physiological effector DPG were essentially unchanged by up to 30% NO-heme in the samples. As will be discussed, under physiological conditions the interactions of Hb with NO provide protection against nitrosative damage without impairing O2 transport by Hb's unoccupied heme sites. This article is part of a Special Issue entitled: Oxygen Binding and Sensing Proteins. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Hemoglobin concentrations and associated factors in adolescentes from Recife, Brazil

    Elisângela Barros Soares Mendonça; Lilian Ferreira Muniz; Ilma Kruze Grande de Arruda; Alcides da Silva Diniz

    2014-01-01

    OBJECTIVE: To estimate the prevalence of anemia and associated factors in adolescents from the city of Recife in Pernambuco state. METHODS: This is a cross-sectional study, involving a random sample of 256 adolescents of both genders, aged 13 to 18, whose hemoglobin concentrations were evaluated, along with their nutritional status and socioeconomic and demographic characteristics. RESULTS: The prevalence of inadequate hemoglobin concentrations was 10.2% [CI95%=6.7-14.5], reaching levels cons...

  18. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    Nuinoon, Manit; Kruachan, Kwanta; Sengking, Warachaya; Horpet, Dararat; Sungyuan, Ubol

    2014-01-01

    Thalassemia and hemoglobin E (Hb E) are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were ...

  19. Individualized Anemia Management Reduces Hemoglobin Variability in Hemodialysis Patients

    Gaweda, Adam E.; Aronoff, George R.; Jacobs, Alfred A.; Rai, Shesh N.; Brier, Michael E.

    2013-01-01

    One-size-fits-all protocol-based approaches to anemia management with erythropoiesis-stimulating agents (ESAs) may result in undesired patterns of hemoglobin variability. In this single-center, double-blind, randomized controlled trial, we tested the hypothesis that individualized dosing of ESA improves hemoglobin variability over a standard population-based approach. We enrolled 62 hemodialysis patients and followed them over a 12-month period. Patients were randomly assigned to receive ESA ...

  20. EPR studies of cooperative binding of Cu (II) to hemoglobin

    Louro, S.R.W.; Tabak, M.

    1983-07-01

    The investigation of the relative affinities of the two pairs of hemoglobin copper sites by monitoring the EPR spectra of the complexes formed by the reaction of copper with deoxyhemoglobin is reported. A model in which two sites are assumed to accept copper ions in a noncooperative way is not able to predict the experimental results. Thus it is conclude that the binding of these ions to hemoglobin is a cooperative phenomenon. (Author) [pt

  1. Comparative study of bedside and laboratory measurements of hemoglobin.

    Krenzischek, D A; Tanseco, F V

    1996-11-01

    The purpose of this study was to examine the effects of variations in technique on measurements of hemoglobin level done at the bedside and to compare these results with laboratory measurements of hemoglobin. In accordance with hospital policy, procedure, and protocol, various techniques were used to obtain samples of capillary and venous blood and of blood from arterial and central venous catheters. Levels of hemoglobin were measured at the bedside and in the laboratory, and the results were compared. The Johns Hopkins Hospital adult postanesthesia care unit. A total of 187 blood samples were obtained from 62 adults who had undergone general surgery. Group I comprised 20 subjects with capillary and venous blood samples. Group II comprised 21 subjects with arterial blood samples. Group III comprised 21 subjects with central venous blood samples. The results showed that the amount of blood to be discarded before obtaining samples of arterial and central venous blood need not be any larger than double the dead space of the catheter, and that shaking the blood sample for 10 seconds was sufficient to mix the sample before measurement of hemoglobin levels. Results of bedside and laboratory measurements of hemoglobin level were comparable. Bedside measurement of hemoglobin increases efficiency in patient care, decreases risk of blood-transmitted infection for staff, and decreases cost to the patient. However, the persons who perform the assay must be responsible in adhering to the standard of practice to minimize errors in the measurements.

  2. Cell volume regulation in hemoglobin CC and AA erythrocytes

    Berkowitz, L.R.; Orringer, E.P.

    1987-01-01

    Swelling hemoglobin CC erythrocytes stimulates a ouabain-insensitive K flux that restores original cell volume. Studies were performed with the K analog, 86 Rb. This volume regulatory pathway was characterized for its anion dependence, sensitivity to loop diuretics, and requirement for Na. The swelling-induced K flux was eliminated if intracellular chloride was replaced by nitrate and both swelling-activated K influx and efflux were partially inhibited by 1 mM furosemide or bumetanide. K influx in swollen hemoglobin CC cells was not diminished when Na in the incubation medium was replaced with choline, indicating Na independence of the swelling-induced flux. Identical experiments with hemoglobin AA cells also demonstrated a swelling-induced increase in K flux, but the magnitude and duration of this increase were considerably less than that seen with hemoglobin CC cells. The increased K flux in hemoglobin AA cells was likewise sensitive to anion replacement and to loop diuretics and did not require the presence of Na. These data indicate that a volume-activated K pathway with similar transport characteristics exists in both hemoglobin CC and AA red cells

  3. Share and share alike: encouraging the reuse of academic resources through the Scottish electronic Staff Development Library

    Lorna M. Campbell

    2001-12-01

    Full Text Available The Scottish electronic Staff Development Library (http://www.sesdl.scotcit.acuk is an ongoing collaborative project involving the Universities of Edinburgh, Paisley and Strathclyde which has been funded by SHEFC as part of their current ScotCIT Programme (http:llwww.scotcit.ac.uk. This project is being developed in response to the increasing demand for flexible, high-quality staff development materials.

  4. Comparison of Hemoglobin Levels Before and After Hemodialysis and Their Effects on Erythropoietin Dosing and Cost

    Sagheb; Fallahzadeh; Moaref; Fallahzadeh; Dormanesh

    2016-01-01

    Background Hemoglobin levels measured after hemodialysis, as compared to hemoglobin levels measured before hemodialysis, are suggested to be a more accurate reflection of the hemoglobin levels between hemodialysis sessions, and to be a better reference point for adjusting erythropoietin dosing. Objectives The aim of this study was to compare the hemoglobin levels before and after hemodialysis, to calculate the required erythropoie...

  5. Success factors for implementing and sustaining a mature electronic medical record in a low-resource setting: a case study of iSanté in Haiti.

    deRiel, E; Puttkammer, N; Hyppolite, N; Diallo, J; Wagner, S; Honoré, J G; Balan, J G; Celestin, N; Vallès, J S; Duval, N; Thimothé, G; Boncy, J; Coq, N R L; Barnhart, S

    2018-03-01

    Electronic health information systems, including electronic medical records (EMRs), have the potential to improve access to information and quality of care, among other things. Success factors and challenges for novel EMR implementations in low-resource settings have increasingly been studied, although less is known about maturing systems and sustainability. One systematic review identified seven categories of implementation success factors: ethical, financial, functionality, organizational, political, technical and training. This case study applies this framework to iSanté, Haiti's national EMR in use in more than 100 sites and housing records for more than 750 000 patients. The author group, consisting of representatives of different agencies within the Haitian Ministry of Health (MSPP), funding partner the Centers for Disease Control and Prevention (CDC) Haiti, and implementing partner the International Training and Education Center for Health (I-TECH), identify successes and lessons learned according to the seven identified categories, and propose an additional cross-cutting category, sustainability. Factors important for long-term implementation success of complex information systems are balancing investments in hardware and software infrastructure upkeep, user capacity and data quality control; designing and building a system within the context of the greater eHealth ecosystem with a plan for interoperability and data exchange; establishing system governance and strong leadership to support local system ownership and planning for system financing to ensure sustainability. Lessons learned from 10 years of implementation of the iSanté EMR system are relevant to sustainability of a full range of increasingly interrelated information systems (e.g. for laboratory, supply chain, pharmacy and human resources) in the health sector in low-resource settings. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene

  6. Quantification of hemoglobin and its derivatives in oral cancer diagnosis by diffuse reflectance spectroscopy

    Kaniyappan, Udayakumar; Gnanatheepam, Einstein; Aruna, Prakasarao; Dornadula, Koteeswaran; Ganesan, Singaravelu

    2017-02-01

    Cancer is one of the most common threat to human beings and it increases at an alarming level around the globe. In recent years, due to the advancements in opto-electronic technology, various optical spectroscopy techniques have emerged to assess the photophysicochemical and morphological conditions of normal and malignant tissues in micro as well as in macroscopic scale. In this regard, diffuse reflectance spectroscopy is considered to be the simplest, cost effective and rapid technique in diagnosis of cancerous tissues. In the present study, the hemoglobin concentration in normal and cancerous oral tissues was quantified and subsequent statistical analysis has been carried out to verify the diagnostic potentiality of the technique.

  7. Identification of a haptoglobin-hemoglobin complex in the Alaskan Least Cisco (Coregonus sardinella).

    Wahl, S M; Boger, J K; Michael, V; Duffy, L K

    1992-01-01

    The hemoglobin and a hemoglobin binding protein have been characterized in the Arctic fish (Coregonus sardinella). The evolutionary significance of the hemoglobin and plasma protein differences between fish and mammals is still unresolved. Blood samples from the Alaskan Least Cisco were separated into plasma and hemoglobin fractions and the proteins in these fractions were analyzed both by alkaline agarose gel electrophoresis, by isolelectric focusing, and by capillary electrophoresis. Staining the plasma proteins gels with o-dianisidine revealed hemoglobin containing protein complexes. A hemoglobin-containing band was observed in hemolyzed plasma which did not migrate with free hemoglobin, and is believed to be hemoglobin-haptoglobin complex. Size exclusion chromatography further characterized the hemoglobin as disassociating freely into dimers, and hemoglobin-haptoglobin complex having a molecular weight greater then 200,000 daltons.

  8. The narrow therapeutic window of glycated hemoglobin and assay variability.

    Hosseini, S S; Bibler, I; Charles, M A

    1999-12-01

    Glycated hemoglobin is measured by a variety of assays, each of which has a unique normal level. Our purpose is to show that among the different assays available in the United States, using the same patient's blood sample, assay results may vary widely and may more or less easily achieve a glycated hemoglobin value within the normal range. The following assays were compared using the same patient's blood sample for each pair of assays: glycohemoglobin affinity assay (GHB Reader; Isolab, Akron, OH) versus gel electrophoresis assay (n = 76); Isolab versus ion capture assay (IMX; Abbott Laboratories, Irving, TX) (n = 57); monoclonal antibody assay (DCA2000; Bayer Diagnostics, Pittsburgh, PA) versus IMX (n = 100); and high-performance liquid chromatography (HPLC) assay (Bio-Rad Variant A1c; Bio-Rad Laboratories, Richmond, CA) versus IMX assay (n = 55). Our analyses indicate that a relative ranking can be established for the ease of achieving a normal glycated hemoglobin level. The ranking indicates that the most stringent or difficult assays for achieving a normal level are the Isolab and DCA2000 assays. The intermediate assays are the IMX and Bio-Rad Variant, and the easiest method for achieving a normal value is the gel electrophoresis assay. Our results indicate that various glycated hemoglobin assays vary widely and are associated with more or less difficulty for an individual patient to achieve a glycated hemoglobin level within the normal range. These results are especially significant with respect to (1) the clinically narrow therapeutic window of glycated hemoglobin values in type 1 diabetes to avoid rapidly advancing severe hypoglycemia rates and chronic microvascular complication rates, and (2) the glycated hemoglobin threshold for rapidly advancing macrovascular disease in both type 1 and type 2 patients.

  9. Propanil-induced methemoglobinemia and hemoglobin binding in the rat

    McMillan, D.C.; McRae, T.A.; Hinson, J.A. (National Center for Toxicological Research, Jefferson, AR (USA))

    1990-09-15

    Administration of (ring-U-14C)propanil (3,4-dichloropropionanilide) to male Sprague-Dawley rats (30, 100, and 300 mg/kg, ip) increased the formation of methemoglobin at the two highest doses. Following a propanil dose of 100 mg/kg, methemoglobin formation attained a maximum level of 5% by 1.5 hr and declined to normal levels (approximately 2.5%) by 12 hr. Hemoglobin binding attained a maximum level of 50 pmol/mg protein by 12 hr, and remained constant for 24 hr. Following a propanil dose of 300 mg/kg, methemoglobin formation attained a maximum level of 24% by 4.5 hr, and declined to a level of 5% by 24 hr. Hemoglobin binding attained a maximum level of 425 pmol/mg protein by 12 hr, and remained constant for 24 hr. Hemoglobin binding was also detected at the lowest propanil dose (10 pmol/mg protein) even though methemoglobin formation was not observed. HPLC analysis of alkaline-treated hemoglobin from propanil-treated rats indicated the presence of one radiolabeled compound with the same HPLC retention time as 3,4-dichloraniline. These data are consistent with the concept that propanil is converted to N-hydroxy-3,4-dichloroaniline in the liver. Subsequently, this metabolite enters the erythrocyte and is oxidized by hemoglobin to 3,4-dichloronitrosobenzene with concomitant conversion of oxyhemoglobin to methemoglobin. The 3,4-dichloronitrosobenzene binds to cysteine residues on hemoglobin as the corresponding sulfinic acid amide adduct. These data suggest that human exposure to propanil may be monitored in the absence of observable toxicity by the analysis of propanil metabolites bound to hemoglobin.

  10. Plant hemoglobins: Important players at the crossroads between oxygen and nitric oxide

    Gupta, Kapuganti J; Hebelstrup, Kim; Mur, Luis A J

    2011-01-01

    Plant hemoglobins constitute a diverse group of hemeproteins and evolutionarily belong to three different classes. Class 1 hemoglobins possess an extremely high affinity to oxygen and their main function consists in scavenging of nitric oxide (NO) at very low oxygen levels. Class 2 hemoglobins have...... at high O2 concentrations. Depending on their physical properties, hemoglobins belong either to hexacoordinate non-symbiotic or pentacoordinate symbiotic groups. Plant hemoglobins are plausible targets for improving resistance to multiple stresses....

  11. Selection of aptamers specific for glycated hemoglobin and total hemoglobin using on-chip SELEX.

    Lin, Hsin-I; Wu, Ching-Chu; Yang, Ching-Hsuan; Chang, Ko-Wei; Lee, Gwo-Bin; Shiesh, Shu-Chu

    2015-01-21

    Blood glycated hemoglobin (HbA1c) levels reflecting average glucose concentrations over the past three months are fundamental for the diagnosis, monitoring, and risk assessment of diabetes. It has been hypothesized that aptamers, which are single-stranded DNAs or RNAs that demonstrate high affinity to a large variety of molecules ranging from small drugs, metabolites, or proteins, could be used for the measurement of HbA1c. Aptamers are selected through an in vitro process called systematic evolution of ligands by exponential enrichment (SELEX), and they can be chemically synthesized with high reproducibility at relatively low costs. This study therefore aimed to select HbA1c- and hemoglobin (Hb)-specific single-stranded DNA aptamers using an on-chip SELEX protocol. A microfluidic SELEX chip was developed to continuously and automatically carry out multiple rounds of SELEX to screen specific aptamers for HbA1c and Hb. HbA1c and Hb were first coated onto magnetic beads. Following several rounds of selection and enrichment with a randomized 40-mer DNA library, specific oligonucleotides were selected. The binding specificity and affinity were assessed by competitive and binding assays. Using the developed microfluidic system, the incubation and partitioning times were greatly decreased, and the entire process was shortened dramatically. Both HbA1c- and Hb-specific aptamers selected by the microfluidic system showed high specificity and affinity (dissociation constant, Kd = 7.6 ± 3.0 nM and 7.3 ± 2.2 nM for HbA1c and Hb, respectively). With further refinements in the assay, these aptamers may replace the conventional antibodies for in vitro diagnostics applications in the near future.

  12. Selection and Evaluation of Electronic Resources Elektronik Kaynakların Seçimi ve Değerlendirilmesi

    Doğan Atılgan

    2009-12-01

    Full Text Available Publication boom and issues related to controlling and accession of printed sources have created some problems after World War II. Consequently, publishing industry has encountered the problem of finding possible solution for emerged situation. Industry of electronic publishing has started to improve with the rapid increase of the price of printed sources as well as the problem of publication boom. The first effects of electronic publishing were appeared on the academic and scholarly publications then electronic publishing became a crucial part of all types of publications. As a result of these developments, collection developments and service policies of information centers were also significantly changed. In this article, after a general introduction about selection and evaluation processes of electronic publications, the subscribed databases by a state and a privately owned university in Turkey and their usage were examined. İkinci dünya savaşından sonra görülen yayın patlaması, basılı kaynakların denetim ve erişiminde sorunlar yaşanmasına neden olmuştur. Bu da yayıncılık sektöründe yeni arayışlara yol açmıştır. 1980’li yıllardan sonra basılı yayın fiyatlarındaki hızlı artış da bu etmenlere eklenince elektronik yayıncılık sektörü gelişmeye başlamıştır. Öncelikle bilimsel ve akademik yayınlarla başlayan elektronik yayın günümüzde tüm yayın türlerini kapsamaktadır. Yayıncılıktaki bu gelişim bilgi merkezlerinin derme geliştirme ve hizmet politikalarını da önemli ölçüde değiştirmiştir. Bu çalışmada elektronik yayınların seçim, değerlendirme ve sağlama konularında genel bir girişten sonra bir devlet üniversitesinin bir de özel üniversitenin abone olduğu veritabanları ve bu veri tabanlarının kullanımının değerlendirilmesi yapılmaktadır.

  13. Combined crystallographic and spectroscopic analysis of Trematomus bernacchii hemoglobin highlights analogies and differences in the peculiar oxidation pathway of Antarctic fish hemoglobins.

    Merlino, Antonello; Vitagliano, Luigi; Howes, Barry D; Verde, Cinzia; di Prisco, Guido; Smulevich, Giulietta; Sica, Filomena; Vergara, Alessandro

    2009-12-01

    Recent studies have demonstrated that hemoglobins isolated from Antarctic fish undergo peculiar oxidation processes. Here we show, by combining crystallographic and spectroscopic data, that the oxidation pathway of Trematomus bernacchii hemoglobin (HbTb) is distinct from that observed for the major component of Trematomus newnesi (Hb1Tn), despite the high sequence identity of the two proteins and structural similarity of their ferrous and fully oxidized states. Resonance Raman analysis of HbTb autoxidation upon air-exposure reveals the absence of the oxidized pentacoordinated state that was observed for Hb1Tn. The HbTb oxidation pathway is characterized by two ferric species: an aquo hexacoordinated high spin state and a bis-histidyl hexacoordinated low spin form, which appear in the early stages of the oxidation process. The high resolution structure of an intermediate along the oxidation pathway has been determined at 1.4 A resolution. The analysis of the electron density of the heme pocket shows, for both the alpha and the beta iron, the coexistence of multiple binding states. In this partially oxidized form, HbTb exhibits significant deviations from the canonical R state both at the local and global level. The analysis of these modifications highlights the structural correlation between key functional regions of the protein.

  14. Potentiality of Melatonin as a Radiation Protector against Hemoglobin Damage in the Experimental Animals Due to Gamma Irradiation

    Farag, H.; Hassan, R. A.; Mohamed, Sh.

    2013-01-01

    Ionizing radiation causes serious damage in biological system. Some drugs and antioxidants are used to prevent such damage. In the present study two doses of melatonin (10 mg⁄kg and 30 mg⁄kg) were selected to be used for such purpose. The radioprotective effects of melatonin on hemoglobin of red blood cells from female mice was studied through UV absorption spectrum, ESR spectroscopy, dielectric measurements and relative viscosity .The results of Hemoglobin absorption indicate that a pronounced increase in the average value of peak position and width at half maximum W hmax followed by a decrease in the absorbance of sort band, decrease in absorption ratio A 578 / A 540 in addition to disappearance of globin band at 275 nm. The free radicals which are expected to be formed after exposing to γ-irradiation are detected by electron spin resonance spectroscopy (ESR). The results indicate that the intensity of ESR signal for hemoglobin extracted from animals exposed to γ- irradiation is greater as compared with normal hemoglobin. Dielectric measurements indicate that there is an increase in dielectric permittivity (ε‵), the dielectric loss (ε‶) and the a.c conductivity (σ ac ) while some decrease is noticed in the viscosity measurements after exposing to irradiation. The data obtained from the whole studied parameters after treating animals with melatonin become closer to those for unirradiated samples.

  15. [Hemoglobin variants in Colombian patients referred to discard hemoglobinopathies].

    Romero-Sánchez, Consuelo; Gómez Gutiérrez, Alberto; Duarte, Yurani; Amazo, Constanza; Manosalva, Clara; Chila M, Lorena; Casas-Gómez, María Consuelo; Briceño Balcázar, Ignacio

    2015-10-01

    Oxygen transport is altered in hemoglobinopathies. To study the distribution of hemoglobinopathies in Andean subjects without African ancestry. We analyzed blood samples of 1,407 subjects aged 18 to 59 years (58% females), living in the central Andean region of Colombia, referred to discard hemoglobinopathies. The frequency and type of hemoglobinopathy was established by capillary and agarose gel electrophoresis. The frequency of hemoglobinopathies was 34.5% and higher among females. The structural variants found were: AS-heterozygous hemoglobin (8.1%), homozygous SS (3.7%), heterozygous SC (2.2%), AC heterozygotes (0.5%) and heterozygous AE (0.3%). Quantitative variants found were Hb A-Beta thalassemia (13.91%) and Hb H (0.06%), Beta-thalassemia heterozygotes C (0.88%), S-Beta thalassemia heterozygotes (6.07%) and compound heterozygous SC/Beta thalassemia (0.25%), with a persistence of fetal hemoglobin 0. Composite thalassemia was also found in 31%. All techniques showed good correlation and capillary electrophoresis demonstrated a greater detection of hemoglobin variants. The frequency of hemoglobin variants in the analyzed population was high, which is an important public health indicator. The most common hemoglobin variant was HbA/Increased structural Hb A2 and the mos frequent structural hemoglobinopathy was sickle cell trait. Capillary electrophoresis can discern any Hb variants present in the population.

  16. Placental morphology at different maternal hemoglobin levels: a histopathological study

    Kiran, N.; Zubair, A.; Malik, T.M.

    2015-01-01

    To evaluate the histopathological parameters of the placenta like weight, infarct and syncytial knots, at different maternal hemoglobin levels, in both qualitative and quantitative manner. Study design: Descriptive study Place and Duration of Study: Army Medical College, National University of Sciences and Technology in collaboration with Department of Obstetrics and Gynecology, Military Hospital, Rawalpindi, Pakistan, from December 2011 to November 2012. Patients and Methods: A total of 75 placentas were included, that were collected from full term mothers at the time of childbirth. Placental weight was taken without umbilical cord and gross placental infarcts were noted. Samples of placental tissue were taken and stained by haematoxylin and eosin (H and E). Microscopic study was done to evaluate placental infarcts and syncytial knots. Results: Mean placental weight at normal and low maternal hemoglobin was 581.67 ± 83.97g and 482.58 ± 104.74g respectively. Gross placental infarcts were found in all cases having low maternal hemoglobin concentration (60% cases). Syncytial knots were found in all placentas but they were considerably more at decreasing levels of maternal hemoglobin (19.79 ± 5.22). Conclusion: The present study showed decrease in placental weight, increase in placental infarcts and syncytial knot hyperplasia at low maternal hemoglobin concentration, displaying adaptive alterations. (author)

  17. Blood hemoglobin level and treatment outcome of early breast cancer

    Henke, M.; Sindlinger, F.; Ikenberg, H.; Gerds, T.; Schumacher, M.

    2004-01-01

    Background and purpose: to determine whether the blood hemoglobin concentration correlates with the prognosis of patients with early breast cancer and, if so, whether this is restricted to treatment modality. Patients and methods: data were collected retrospectively from patients with early breast cancer (T1,2 NO-2 MO) who underwent either breast-conserving surgery followed by adjuvant radiotherapy (BCS-RT; n = 96) or a modified radical mastectomy (MRM; n = 194). The effect of preoperative blood hemoglobin level, nodal status, histological grading and hormone receptor status on disease-free survival was determined for both treatment modalities using a cox regression model and visualized by kaplan-meier plots. Results: the blood hemoglobin concentration significantly correlated with disease-free survival of patients receiving BCS-RT (relative risk [RR]: 0.67 per g/dl; p = 0.007). This was independent of other known risk factors for breast cancer patients, as determined by multivariate analysis. By contrast, the blood hemoglobin level had no prognostic significance when patients were treated with MRM. Conclusion: blood hemoglobin concentration seems to affect the prognosis of patients with early breast cancer when a treatment schedule that includes radiotherapy is applied. Reduced radiosensitivity due to diminished tumor oxygenation may be the underlying cause. Confirmative trials and studies intended to elucidate the underlying mechanism are warranted. (orig.)

  18. The refractive index of human hemoglobin in the visible range

    Zhernovaya, O; Tuchin, V; Sydoruk, O; Douplik, A

    2011-01-01

    Because the refractive index of hemoglobin in the visible range is sensitive to the hemoglobin concentration, optical investigations of hemoglobin are important for medical diagnostics and treatment. Direct measurements of the refractive index are, however, challenging; few such measurements have previously been reported, especially in a wide wavelength range. We directly measured the refractive index of human deoxygenated and oxygenated hemoglobin for nine wavelengths between 400 and 700 nm for the hemoglobin concentrations up to 140 g l -1 . This paper analyzes the results and suggests a set of model functions to calculate the refractive index depending on the concentration. At all wavelengths, the measured values of the refractive index depended on the concentration linearly. Analyzing the slope of the lines, we determined the specific refraction increments, derived a set of model functions for the refractive index depending on the concentration, and compared our results with those available in the literature. Based on the model functions, we further calculated the refractive index at the physiological concentration within the erythrocytes of 320 g l -1 . The results can be used to calculate the refractive index in the visible range for arbitrary concentrations provided that the refractive indices depend on the concentration linearly.

  19. Biophysical Monitoring and dose response characteristics of irradiated hemoglobin

    Elshemey, W.M; Selim, N.S.; Desouky, O.

    2003-01-01

    The present work aims to move a step forward towards a deeper understanding of the scattering of x-ray, from lyophilized biological samples. Comparative study has been performed using LAXS and UV-visible spectrophotometry for monitoring the dose response characteristics of the hemoglobin molecule of irradiated blood. Blood samples were irradiated at doses ranging from 5 up to 100 Gy. Diluted hemoglobin solution was scanned in the UV- visible range (200-700 nm), and lyophilized hemoglobin was prepared for LAXS measurement. The radiation-induced changes in the hemoglobin structure have been evaluated. The LAXS profile of hemoglobin molecule is characterized by the presence of two peaks in the forward direction of scattering. These peaks were found to be sensitive to the variations in the molecular structure of a given sample. The obtained results suggest that the 1 s t peak, recorded at 4.65 o , is sensitive to the tertiary and quaternary structure of the globin part, while the major peak, recorded at 10.5 o , appeared to be related to its primary and secondary structure

  20. Post-transfusion hemoglobin values and patient blood management

    Moerman, Jan; Vermeulen, Edith; Van Mullem, Mia

    2018-01-01

    Objectives: The objective of this retrospective study was to evaluate the added value of communicating post-transfusion hemoglobin values to clinicians as a strategy to improve RBC utilization in a 500-bed hospital. Methods: The total number of RBC transfusions, the mean number of RBC units...... transfused per patient, the mean pre- and post-transfusion hemoglobin values, the ratio of patients transfused and the ratio of patients with a post-transfusion hemoglobin > 10.5 g/dL were calculated per service and per department for six months. The data were reported to each service and compared...... with the data of the department as peer group. The impact of this communication strategy was evaluated in the following six months. Results: In the six months pre-intervention, the mean post-transfusion hemoglobin value was 9.2 g/dL. Post-transfusion hemoglobin was > 10.5 g/dL in 13.4% of patients (112...

  1. Study of LAXS Profile of Hemoglobin from Irradiated Blood

    Selim, N.S.; Desouky, O.S.; Elshemey, W.M.

    2006-01-01

    The present work aims to move a step forward towards a deeper understanding of the scattering of x-ray, from lyophilized biological samples. Comparative study has been performed using low angle x-ray scattering (LAXS) and UV-visible spectrophotometry for monitoring the dose response characteristics of the hemoglobin molecule of irradiated blood. Blood samples were exposed to gamma rays, at doses ranging from 5 up to 100 Gy. Diluted hemoglobin solution was scanned in the UV-visible range (200-700 nm), and lyophilized hemoglobin was prepared for LAXS measurement. The radiation-induced changes in the hemoglobin structure have been evaluated. The LAXS profile of hemoglobin molecule is characterized by the presence of 2 peaks in the forward direction of scattering. These peaks were found to be sensitive to the variations in the molecular structure of a given sample. The obtained results suggest that the 1st peak, recorded at 4.65O (equivalent to momentum transfer, x= 0.526 nm-1), is sensitive to the tertiary and quaternary structure of the globin part, while the major peak, recorded at 10.5O (equivalent to momentum transfer, x= 1.189 nm-1), appeared to be related to its primary and secondary structure

  2. Profile of hemoglobin D trait in West Bengal, India

    Tuphan K. Dolai

    2014-04-01

    Full Text Available Hemoglobin (Hb D Punjab is one of the most commonly observed abnormal hemoglobinopathy worldwide. There was no systematic large published study to investigate the characteristic of Hb D Punjab trait in India. This study was conducted in school and college students, newly married couples and pregnant women after proper counseling in the rural areas of West Bengal state in eastern India. Complete blood count was done by Sysmax Automated Hematology Analyzer KX 21 (Sysmex Corp., Kobe, Japan and thalassemia testing was done using high-performance liquid chromatography (Variant TM - Bio-Rad Lab., Hercules, CA, USA. A total of 46,139 individuals were screened for hemoglobinopathies. Hb D trait was found in 0.35%. Hypochromia rather than microcytosis is consistent finding in Hb D trait. Anisocytosis is absent in Hb D trait. In almost all (99.37% cases, Hb D is within 40% of total hemoglobin. This data is likely to be helpful for screening of hemoglobinopathy in resource poor setting.  血红蛋白(Hb D Punjab是全球最普遍的异常血红蛋白病之一。在印度,之前并没有研究D型特征血红蛋白病的大型出版物。本研究在印度东部的西孟加拉邦的农村地区进行,研究对象是接受过相关咨询后的在校生,大学生,新婚夫妇和孕妇。完整的血细胞计数由日本神户市Sysmex公司的KX21自动化血液分析仪完成,血液测试由美国加州赫拉克勒斯Variant-Bio-Rad实验室通过高效液相色谱法完成。总计46139人被筛查,D型特征血红蛋白病的发现率为0.35%。血红蛋白过少而非小红细胞症,是D型特征血红蛋白病的主要症状。红细胞大小不均没有在D型特征血红蛋白病中被检测出。在所有的情况中(99.37%),D型特征血红蛋白占所有血红蛋白总数的40%。这些数据有利于在资源匮乏地区对血红蛋白病的筛查。

  3. Utility of the electronic information resource UpToDate for clinical decision-making at bedside rounds.

    Phua, J; See, K C; Khalizah, H J; Low, S P; Lim, T K

    2012-02-01

    Clinical questions often arise at daily hospital bedside rounds. Yet, little information exists on how the search for answers may be facilitated. The aim of this prospective study was, therefore, to evaluate the overall utility, including the feasibility and usefulness of incorporating searches of UpToDate, a popular online information resource, into rounds. Doctors searched UpToDate for any unresolved clinical questions during rounds for patients in general medicine and respiratory wards, and in the medical intensive care unit of a tertiary teaching hospital. The nature of the questions and the results of the searches were recorded. Searches were deemed feasible if they were completed during the rounds and useful if they provided a satisfactory answer. A total of 157 UpToDate searches were performed during the study period. Questions were raised by all ranks of clinicians from junior doctors to consultants. The searches were feasible and performed immediately during rounds 44% of the time. Each search took a median of three minutes (first quartile: two minutes, third quartile: five minutes). UpToDate provided a useful and satisfactory answer 75% of the time, a partial answer 17% of the time and no answer 9% of the time. It led to a change in investigations, diagnosis or management 37% of the time, confirmed what was originally known or planned 38% of the time and had no effect 25% of the time. Incorporating UpToDate searches into daily bedside rounds was feasible and useful in clinical decision-making.

  4. Hemoglobin is essential for normal growth of Arabidopsis organs

    Hebelstrup, Kim Henrik; Hunt, Peter; Dennis, Elizabeth

    2006-01-01

    In Arabidopsis thaliana, the class I hemoglobin AHb1 is transiently expressed in the hydathodes of leaves and in floral buds from young inflorescences. Nitric oxide (NO) accumulates to high levels in these organs when AHb1 is silenced, indicating an important role in metabolizing NO. AHb1-silenced...... lines are viable but show a mutant phenotype affecting the regions where AHb1 is expressed. Arabidopsis lines with an insertional knockout or overexpression of AHb2, a class II 3-on-3 hemoglobin, were generated. Seedlings overexpressing AHb2 show enhanced survival of hypoxic stress. The AHb2 knockout...... lines develop normally. However, when AHb2 knockout is combined with AHb1 silencing, seedlings die at an early vegetative stage suggesting that the two 3-on-3 hemoglobins, AHb1 and AHb2, together play an essential role for normal development of Arabidopsis seedlings. In conclusion, these results...

  5. An Atomistic View on Human Hemoglobin Carbon Monoxide Migration Processes

    Lucas, M. Fátima; Guallar, Víctor

    2012-01-01

    A significant amount of work has been devoted to obtaining a detailed atomistic knowledge of the human hemoglobin mechanism. Despite this impressive research, to date, the ligand diffusion processes remain unclear and controversial. Using recently developed computational techniques, PELE, we are capable of addressing the ligand migration processes. First, the methodology was tested on myoglobin's CO migration, and the results were compared with the wealth of theoretical and experimental studies. Then, we explored both hemoglobin tense and relaxed states and identified the differences between the α-and β-subunits. Our results indicate that the proximal site, equivalent to the Xe1 cavity in myoglobin, is never visited. Furthermore, strategically positioned residues alter the diffusion processes within hemoglobin's subunits and suggest that multiple pathways exist, especially diversified in the α-globins. A significant dependency of the ligand dynamics on the tertiary structure is also observed. PMID:22385860

  6. Nitric Oxide in Plants: The Roles of Ascorbate and Hemoglobin

    Wang, Xiaoguang; Hargrove, Mark S.

    2013-01-01

    Ascorbic acid and hemoglobins have been linked to nitric oxide metabolism in plants. It has been hypothesized that ascorbic acid directly reduces plant hemoglobin in support of NO scavenging, producing nitrate and monodehydroascorbate. In this scenario, monodehydroascorbate reductase uses NADH to reduce monodehydroascorbate back to ascorbate to sustain the cycle. To test this hypothesis, rates of rice nonsymbiotic hemoglobin reduction by ascorbate were measured directly, in the presence and absence of purified rice monodehydroascorbate reductase and NADH. Solution NO scavenging was also measured methodically in the presence and absence of rice nonsymbiotic hemoglobin and monodehydroascorbate reductase, under hypoxic and normoxic conditions, in an effort to gauge the likelihood of these proteins affecting NO metabolism in plant tissues. Our results indicate that ascorbic acid slowly reduces rice nonsymbiotic hemoglobin at a rate identical to myoglobin reduction. The product of the reaction is monodehydroascorbate, which can be efficiently reduced back to ascorbate in the presence of monodehydroascorbate reductase and NADH. However, our NO scavenging results suggest that the direct reduction of plant hemoglobin by ascorbic acid is unlikely to serve as a significant factor in NO metabolism, even in the presence of monodehydroascorbate reductase. Finally, the possibility that the direct reaction of nitrite/nitrous acid and ascorbic acid produces NO was measured at various pH values mimicking hypoxic plant cells. Our results suggest that this reaction is a likely source of NO as the plant cell pH drops below 7, and as nitrite concentrations rise to mM levels during hypoxia. PMID:24376554

  7. Independency of Fe ions in hemoglobin on immunomagnetic reduction assay

    Yang, S.Y. [MagQu Co. Ltd., Sindian City, Taipei County 231, Taiwan (China); Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Lan, C.B.; Chen, C.H. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Horng, H.E. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China)], E-mail: phyfv001@scc.ntnu.edu.tw; Hong, Chin-Yih [Department of Mechanical Engineering, Nan-Kai University of Technology, Nantau County, Taiwan (China)], E-mail: cyhong@nkut.edu.tw; Yang, H.C. [Department of Physics, National Taiwan University, Taipei 106, Taiwan (China)], E-mail: hcyang@phys.ntu.edu.tw; Lai, Y.K. [College of Life Sciences, National Tsing Hua University, Hsinchu City 300, Taiwan (China); Department of Bioresources, Da-Yeh University, Changhua 515, Taiwan (China); Lin, Y.H.; Teng, K.S. [Apex Biotechnology Co. Ltd., Hsinchu City 300, Taiwan (China)

    2009-10-15

    Immunomagnetic reduction (IMR), which involves measuring the reduction in the ac magnetic susceptibility of magnetic reagents, is due to the association between bio-functionalized magnetic nanoparticles and target bio-molecules. This has been demonstrated for assaying proteins in solutions free of Fe ions, such as serum. In this work, the validity of IMR assay for samples rich in Fe ions like hemoglobin (Hb) is investigated. According to the results, there is no magnetic signal contributed by Fe-ion-rich Hb. Furthermore, the results show a high sensitivity in assaying hemoglobin A1c (HbA1c) by using IMR.

  8. Dichloromethane as an antisickling agent in sickle cell hemoglobin

    Schoenborn, B.P.; North, B.E.

    1977-01-01

    Observations are reported that show that dichloromethane (DCM) does have a significant effect on the oxygen binding properties of hemoglobin. At DCM pressures high enough to prevent or reverse sickling, DCM would lower the oxygen affinity of hemoglobin, therefore reducing oxygen transport at low oxygen pressure. This decrease in oxygen affinity might, however, increase the oxygen availability to tissue as long as a sufficiently large lung P/sub O/sub 2// is maintained. Crystallographic studies show that site D4 has a much lower affinity for DCM than site D3 while sites D1 and D2 show a higher affinity.

  9. Independency of Fe ions in hemoglobin on immunomagnetic reduction assay

    Yang, S.Y.; Lan, C.B.; Chen, C.H.; Horng, H.E.; Hong, Chin-Yih; Yang, H.C.; Lai, Y.K.; Lin, Y.H.; Teng, K.S.

    2009-01-01

    Immunomagnetic reduction (IMR), which involves measuring the reduction in the ac magnetic susceptibility of magnetic reagents, is due to the association between bio-functionalized magnetic nanoparticles and target bio-molecules. This has been demonstrated for assaying proteins in solutions free of Fe ions, such as serum. In this work, the validity of IMR assay for samples rich in Fe ions like hemoglobin (Hb) is investigated. According to the results, there is no magnetic signal contributed by Fe-ion-rich Hb. Furthermore, the results show a high sensitivity in assaying hemoglobin A1c (HbA1c) by using IMR.

  10. Why are there two kinds of chain in tetrameric hemoglobins

    Ferreira, R.; Jacchieri, S.G.

    1981-01-01

    The homeotropic allosteric interactions responsible for the sigmoidal oxygen saturation curves of α 2 β 2 hemoglobins are shown to be larger than those of hypothetical hemoglobins obeying identical curves and built from equivalent chains, γ 4 . It is also shown that this ensures for the α 2 β 2 species a more dependable cooperativity, through a biologically significative temperature range. On the basis of these findings it is argued that the existence of two different globin chains is advantageous in an evolutionary sense. (Author) [pt

  11. Postoperative hemoglobin level in patients with femoral neck fracture

    Nagra, Navraj; van Popta, Dmitri; Whiteside, Sigrid; Holt, Edward

    2018-01-01

    Objective: The aim of this study was to analyze the changes of hemoglobin levels in patients undergoing fixation for femoral neck fracture.Methods: Peroperative hemoglobin levels of patients who underwent either dynamic hip screw (DHS) fixation (n=74; mean age: 80 years) or hip hemiarthroplasty (n=104; mean age: 84 years) for femoral neck fracture was monitored.Results: There was a statistically and clinically significant mean drop of 31.1 g/L between the preoperative (D0) and postoperative D...

  12. Respiratory properties of blood and hemoglobin solutions from the piranha

    Wood, S.C.; Weber, Roy E.; Powers, D.

    1979-01-01

    1. Respiratory properties of piranha blood are distinguished from those of other fish primarily by the high CO2 buffering capacity (?HCO3/-?pH= 19.6mmol/l for oxygenated blood and 39.1 mmol/l for deoxygenated blood). 2. The concentration of nucleoside triphosphates (NTP) and the half-saturation t......) lowered the oxygen affinity of purified hemoglobin solutions, accounting for the size-dependent correlation ofP50 and NTP concentration in whole blood. 5. While similar in concentration in red cells, GTP is more potent than ATP as an allosteric modifier of hemoglobin function....

  13. Is Routine Ordering of Both Hemoglobin and Hematocrit Justifiable?

    Addison, David J.

    1966-01-01

    In order to assess the value of routine simultaneous hemoglobin and hematocrit determinations, paired determinations in the following groups were studied: (1) 360 consecutive pairs from the hematology laboratory, (2) 95 pairs on general medical patients, (3) 43 pairs on 10 patients with upper gastrointestinal hemorrhage, and (4) 62 pairs on 10 patients with burns. These values were plotted on scatter diagrams. In the 560 pairs only three disparate determinations were found. It is concluded that, in most clinical situations, determination of the hemoglobin or the hematocrit as a screening procedure provides as much useful information as the simultaneous determination of both. PMID:5296947

  14. Comprehensive evaluation of electronic medical record system use and user satisfaction at five low-resource setting hospitals in ethiopia.

    Tilahun, Binyam; Fritz, Fleur

    2015-05-25

    Electronic medical record (EMR) systems are increasingly being implemented in hospitals of developing countries to improve patient care and clinical service. However, only limited evaluation studies are available concerning the level of adoption and determinant factors of success in those settings. The objective of this study was to assess the usage pattern, user satisfaction level, and determinants of health professional's satisfaction towards a comprehensive EMR system implemented in Ethiopia where parallel documentation using the EMR and the paper-based medical records is in practice. A quantitative, cross-sectional study design was used to assess the usage pattern, user satisfaction level, and determinant factors of an EMR system implemented in Ethiopia based on the DeLone and McLean model of information system success. Descriptive statistical methods were applied to analyze the data and a binary logistic regression model was used to identify determinant factors. Health professionals (N=422) from five hospitals were approached and 406 responded to the survey (96.2% response rate). Out of the respondents, 76.1% (309/406) started to use the system immediately after implementation and user training, but only 31.7% (98/309) of the professionals reported using the EMR during the study (after 3 years of implementation). Of the 12 core EMR functions, 3 were never used by most respondents, and they were also unaware of 4 of the core EMR functions. It was found that 61.4% (190/309) of the health professionals reported over all dissatisfaction with the EMR (median=4, interquartile range (IQR)=1) on a 5-level Likert scale. Physicians were more dissatisfied (median=5, IQR=1) when compared to nurses (median=4, IQR=1) and the health management information system (HMIS) staff (median=2, IQR=1). Of all the participants, 64.4% (199/309) believed that the EMR had no positive impact on the quality of care. The participants indicated an agreement with the system and information

  15. Hemoglobin binding of aromatic amines: molecular dosimetry and quantitative structure-activity relationships for N-oxidation.

    Sabbioni, G

    1993-01-01

    Aromatic amines are important intermediates in industrial manufacturing. N-Oxidation to N-hydroxyarylamines is a key step in determining the genotoxic properties of aromatic amines. N-Hydroxyarylamines can form adducts with DNA, with tissue proteins, and with the blood proteins albumin and hemoglobin in a dose-dependent manner. The determination of hemoglobin adducts is a useful tool for biomonitoring exposed populations. We have established the hemoglobin binding index (HBI) [(mmole compound/mole hemoglobin)/(mmole compound/kg body weight)] of several aromatic amines in female Wistar rats. Including the values from other researchers obtained in the same rat strain, the logarithm of hemoglobin binding (logHBI) was plotted against the following parameters: the sum of the Hammett constants(sigma sigma = sigma p + sigma m), pKa, logP (octanol/water), the half-wave oxidation potential (E1/2), and the electronic descriptors of the amines and their corresponding nitrenium ions obtained by semi-empirical calculations (MNDO, AMI, and PM3), such as atomic charge densities, energies of the highest occupied molecular orbit and lowest occupied molecular orbit and their coefficients, the bond order of C-N, the dipole moments, and the reaction enthalpy [MNDOHF, AM1HF or PM3HF = Hf(nitrenium) - Hf(amine)]. The correlation coefficients were determined from the plots of all parameters against log HBI for all amines by means of linear regression analysis. The amines were classified in three groups: group 1, all parasubstituted amines (maximum, n = 9); group 2, all amines with halogens (maximun, n = 11); and group 3, all amines with alkyl groups (maximum, n = 13).(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8319626

  16. A novel hydrogen peroxide biosensor based on hemoglobin-collagen-CNTs composite nanofibers.

    Li, J; Mei, H; Zheng, W; Pan, P; Sun, X J; Li, F; Guo, F; Zhou, H M; Ma, J Y; Xu, X X; Zheng, Y F

    2014-06-01

    In this paper, carbon nanotubes (CNTs) were successfully incorporated in the composite composed of hemoglobin (Hb) and collagen using co-electrospinning technology. The formed Hb-collagen-CNTs composite nanofibers possessed distinct advantage of three-dimensional porous structure, biocompatibility and excellent stability. The Hb immobilized in the electrospun nanofibers retained its natural structure and the heterogeneous electron transfer rate constant (ks) of the direct electron transfer between Hb and electrodes was 5.3s(-1). In addition, the electrospun Hb-collagen-CNTs nanofibers modified electrodes showed good electrocatalytic properties toward H2O2 with a detection limit of 0.91μM (signal-to-noise ratio of 3) and the apparent Michaelis-Menten constant (Km(app)) of 32.6μM. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. The effect of ionizing radiation on hemoglobin synthesis

    Lipinski, S

    1972-01-01

    The effect of ionizing radiation on hemoglobin synthesis was studied and its effect on the quality of protein was discovered. The biological effects due to the changes in the structure of protein were also observed. The results of the experiments are presented.

  18. Recombinant bacterial hemoglobin alters metabolism of Aspergillus niger

    Hofmann, Gerald; Diano, Audrey; Nielsen, Jens

    2009-01-01

    , the fungus will produce various by-products like organic acids and polyols. In order to circumvent this problem we here study the effects of the expression of a bacterial hemoglobin protein on the metabolism of A. niger. We integrated the vgb gene from Vitreoscilla sp. into the genome at the pyrA locus...

  19. Relationship of Hemoglobin to Arterial Oxygen Desaturation during Aeromedical Evacuation

    2015-04-02

    2. REPORT TYPE Special Report 3. DATES COVERED (From – To) September 2012 – September 2014 4. TITLE AND SUBTITLE Relationship of Hemoglobin to...pressurized pulsatile, and hydrosurgery debridement methods for removing bacteria from fracture implants. Orthopedics. 2012; 35(7):e1046-e1050. 11. Burns TC

  20. Hemoglobin is essential for normal growth of Arabidopsis organs

    Hebelstrup, Kim Henrik; Hunt, Peter; Dennis, Elizabeth

    2006-01-01

    In Arabidopsis thaliana, the class I hemoglobin AHb1 is transiently expressed in the hydathodes of leaves and in floral buds from young inflorescences. Nitric oxide (NO) accumulates to high levels in these organs when AHb1 is silenced, indicating an important role in metabolizing NO. AHb1-silence...... suggests that 3-on-3 hemoglobins apart from a role in hypoxic stress play a general role under non-stressed conditions where they are essential for normal development by controlling the level of NO which tends to accumulate in floral buds and leaf hydathodes of plants......In Arabidopsis thaliana, the class I hemoglobin AHb1 is transiently expressed in the hydathodes of leaves and in floral buds from young inflorescences. Nitric oxide (NO) accumulates to high levels in these organs when AHb1 is silenced, indicating an important role in metabolizing NO. AHb1-silenced...... lines are viable but show a mutant phenotype affecting the regions where AHb1 is expressed. Arabidopsis lines with an insertional knockout or overexpression of AHb2, a class II 3-on-3 hemoglobin, were generated. Seedlings overexpressing AHb2 show enhanced survival of hypoxic stress. The AHb2 knockout...

  1. Effect of some high consumption spices on hemoglobin glycation.

    Naderi, G H; Dinani, Narges J; Asgary, S; Taher, M; Nikkhoo, N; Boshtam, M

    2014-01-01

    Formation of glycation products is major factor responsible in complications of diabetes. Worldwide trend is toward the use of natural additives in reducing the complications of diseases. Therefore, there is a growing interest in natural antiglycation found in plants. Herbs and spices are one of the most important targets to search for natural antiglycation from the point of view of safety. This study investigated the ability of some of the spices to inhibit glycation process in a hemoglobin/glucose model system and compared their potency with each other. For this subject the best concentration and time to incubate glucose with hemoglobin was investigated. Then the glycosylation degree of hemoglobin in the presence of extracts by the three concentrations 0.25, 0.5 and 1 μg/ml was measured colorimetrically at 520 nm. Results represent that some of extracts such as wild caraway, turmeric, cardamom and black pepper have inhibitory effects on hemoglobin glycation. But some of the extracts such as anise and saffron have not only inhibitory effects but also aggravated this event and have proglycation properties. In accordance with the results obtained we can conclude that wild caraway, turmeric, cardamom and black pepper especially wild caraway extracts are potent antiglycation agents, which can be of great value in the preventive glycation-associated complications in diabetes.

  2. Site-specific semisynthetic variant of human hemoglobin

    Hefta, S.A.; Lyle, S.B.; Busch, M.R.; Harris, D.E.; Matthew, J.B.; Gurd, F.R.N.

    1988-01-01

    A single round of Edman degradation was employed to remove the NH 2 -terminal valine from isolated α chains of human hemoglobin. Reconstitution of normal β chains with truncated or substituted α chains was used to form truncated (des-Val 1 -α1) and substituted ([[1- 13 C]Gly 1 ]α1) tetrameric hemoglobin analogs. Structural homology of the analogs with untreated native hemoglobin was established by using several spectroscopic and physical methods. Functional studies indicate that the reconstituted tetrameric protein containing des-Val 1 -α chains has a higher affinity for oxygen, is less influenced by chloride ions or 2,3-biphosphoglycerate, and shows lower cooperativity than native hemoglobin. These results confirm the key functional role of the α-chain NH 2 terminus in mediating cooperative oxygen binding across the dimer interface. The NH 2 -terminal pK/sub 1/2/ value was determined for the [ 13 C]glycine-substituted analog to be 7.46 +/- 0.09 at 15 0 C in the carbon monoxide-liganded form. This value, measured directly by 13 C NMR, agrees with the determination made by the less-direct 13 CO 2 method and confirms the role of this residue as a contributor to the alkaline Bohr effect; however, it is consistent with the presence of an NH 2 -terminal salt bridge to the carboxylate of Arg-141 of the α chain in the liganded form

  3. A Review on hematology and hemoglobin of fish

    Ebru YILMAZ

    2015-01-01

    Full Text Available Determination of hematological parameters of fish living in natüre helps to recognize population and to determinate of pollutants in the aquatic environment. In this review, hematological parameters of fish, fish hemoglobin and the Bohr effect were given information.

  4. Influence of hemoglobin on non-invasive optical bilirubin sensing

    Jiang, Jingying; Gong, Qiliang; Zou, Da; Xu, Kexin

    2012-03-01

    Since the abnormal metabolism of bilirubin could lead to diseases in the human body, especially the jaundice which is harmful to neonates. Traditional invasive measurements are difficult to be accepted by people because of pain and infection. Therefore, the real-time and non-invasive measurement of bilirubin is of great significance. However, the accuracy of currently transcutaneous bilirubinometry(TcB) is generally not high enough, and affected by many factors in the human skin, mostly by hemoglobin. In this talk, absorption spectra of hemoglobin and bilirubin have been collected and analyzed, then the Partial Least Squares (PLS) models have been built. By analyzing and comparing the Correlation and Root Mean Square Error of Prediction(RMSEP), the results show that the Correlation of bilirubin solution model is larger than that of the mixture solution added with hemoglobin, and its RMSEP value is smaller than that of mixture solution. Therefore, hemoglobin has influences on the non-invasive optical bilirubin sensing. In next step, it is necessary to investigate how to eliminate the influence.

  5. Glycated Hemoglobin Measurement and Prediction of Cardiovascular Disease

    Di Angelantonio, Emanuele; Gao, Pei; Khan, Hassan

    2014-01-01

    IMPORTANCE: The value of measuring levels of glycated hemoglobin (HbA1c) for the prediction of first cardiovascular events is uncertain. OBJECTIVE: To determine whether adding information on HbA1c values to conventional cardiovascular risk factors is associated with improvement in prediction of c...

  6. 21 CFR 864.7470 - Glycosylated hemoglobin assay.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Glycosylated hemoglobin assay. 864.7470 Section 864.7470 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7470...

  7. 21 CFR 864.7415 - Abnormal hemoglobin assay.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Abnormal hemoglobin assay. 864.7415 Section 864.7415 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7415 Abnormal...

  8. 21 CFR 864.5620 - Automated hemoglobin system.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated hemoglobin system. 864.5620 Section 864.5620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  9. 21 CFR 864.7500 - Whole blood hemoglobin assays.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Whole blood hemoglobin assays. 864.7500 Section 864.7500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7500 Whole...

  10. 21 CFR 864.7440 - Electrophoretic hemoglobin analysis system.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrophoretic hemoglobin analysis system. 864.7440 Section 864.7440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864...

  11. The influence of socioeconomic status on the hemoglobin level and ...

    Materials and Methods: This is a cross-sectional study involving 100 children with SCA and 100 age-, sex-, and social class-matched controls that fulfilled the inclusion criteria. Social class was assessed using educational attainment and occupation of parents. Hemoglobin concentration was determined using the ...

  12. A Microplate Assay for the Determination of Hemoglobin Concentration

    Frenchik, Michael D; McFaul, Steve J; Tsonev, Latchezar I

    2004-01-01

    ... (NaOH), and converts all hemoglobin species, including COHb, to AHD within 5 min. Both protocols are carried out in cuvettes, and are, therefore, time intensive and difficult to manage when many samples are quantified. This impedes acquisition of triplicate values for each sample necessary to improve accuracy and determine statistical significance.

  13. Expression and purification of recombinant hemoglobin in Escherichia coli

    Natarajan, Chandrasekhar; Jiang, Xiaoben; Fago, Angela

    2011-01-01

    BACKGROUND: Recombinant DNA technologies have played a pivotal role in the elucidation of structure-function relationships in hemoglobin (Hb) and other globin proteins. Here we describe the development of a plasmid expression system to synthesize recombinant Hbs in Escherichia coli, and we describe...

  14. Importance of hemoglobin concentration to exercise: acute manipulations

    Calbet, José A L; Lundby, Carsten; Koskolou, Maria

    2006-01-01

    An acute reduction of blood hemoglobin concentration ([Hb]), even when the circulating blood volume is maintained, results in lower (.)V(O(2)(max) and endurance performance, due to the reduction of the oxygen carrying capacity of blood. Conversely, an increase of [Hb] is associated with enhanced...

  15. Myth or reality : Hematocrit and hemoglobin differ in trauma

    Nijboer, Johanna M. M.; van der Horst, Iwan C. C.; Hendriks, Herman G. D.; ten Duis, Hendrik-Jan; Nijsten, Maarten W. N.

    Background: Estimating blood loss in trauma patients usually involves the determination of hematocrit (Ht) or hemoglobin (Hb). However, in trauma patients, a poorly substantiated habit exists to determine both Ht and Hb in assessing acute blood loss. This suggests that Ht and Hb provide different

  16. Nonenzymatic glycosylation of human hemoglobin at multiple sites

    Shapiro, R.; McManus, M.; Garrick, L.; McDonald, M.J.; Bunn, H.F.

    1979-01-01

    The most abundant minor hemoglobin component of human hemolysate is Hb A1c, which has glucose bound to the N-terminus of the beta chain by a ketoamine linkage. Hb A1c is formed slowly and continuously throughout the 120 day lifespan of the red cell. It can be synthesized in vitro by incubating purified hemoglobin with 14C-glucose. Other minor components, Hb A1a1 and Hb A1a2 are adducts of sugar phosphates at the N-terminus of the beta chain. Hb A1b contains an unidentified nonphosphorylated sugar at the beta N-terminus. In addition, a significant portion of the major hemoglobin component (Hb Ao) is also glycosylated by a glucose ketoamine linkage at other sites on the molecule, including the N-terminus of the alpha chain and the epsilon-amino group of several lysine residues on both the alpha and the beta chains. The results indicate that the interaction of glucose and hemoglobin is rather nonspecific and suggests that other proteins are modified in a similar fashion

  17. Prediction models for hemoglobin deferral in whole blood donors

    Baart, A.M.

    2013-01-01

    Each year, a relevant proportion of the invited blood donors is eventually deferred from donation because of low hemoglobin (Hb) levels. Deferrals are meant to protect donors from developing iron deficiency anemia after a blood donation, however, they may increase the risk of donor lapse, even

  18. Direct electrochemistry of hemoglobin entrapped in dextran film on ...

    Direct electrochemistry of hemoglobin (Hb) entrapped in the dextran (De) film on the surface of a room temperature ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF6) modified carbon paste electrode (CILE) has been investigated. UV-Vis and FT-IR spectroscopy showed that Hb retained its native ...

  19. Relationships between hemoglobin A1c and spot glucose ...

    Background: Glycosylated hemoglobin, HbA1c is the most acceptable measure of chronic glycemia. It is not widely available and/or affordable in Nigeria. The mean of the monthly fasting plasma glucose (MFPG) of the preceding 3 months is often used as surrogate for assessing chronic glycemia. Objective: To determine the ...

  20. Routine hemoglobin electrophoresis for pediatric surgery day case ...

    Background: Hemoglobin electrophoresis (HBE) is a part of the preoperative routine requested by anesthetists. However, the prevalence of hemoglobinopathy in the population is low. This study aims to determine the clinical risk factors for hemoglobinopathies and propose clinical guidelines for preoperative screening of ...

  1. Hemoglobin, Growth, and Attention of Infants in Southern Ethiopia

    Aubuchon-Endsley, Nicki L.; Grant, Stephanie L.; Berhanu, Getenesh; Thomas, David G.; Schrader, Sarah E.; Eldridge, Devon; Kennedy, Tay; Hambidge, Michael

    2011-01-01

    Male and female infants from rural Ethiopia were tested to investigate relations among hemoglobin (Hb), anthropometry, and attention. A longitudinal design was used to examine differences in attention performance from 6 (M = 24.9 weeks, n = 89) to 9 months of age (M = 40.6 weeks, n = 85), differences hypothesized to be related to changes in iron…

  2. Ultrasonic processing for recovery of chicken erythrocyte hemoglobin

    Hemoglobin from chicken blood has been shown to be a good substitute for synthetic polymeric flocculants. One stage of processing the blood entails breaking open the cells and releasing the cytoplasmic contents; in the present study, we investigate the use of ultrasonic processing at this stage. Was...

  3. The Relationship Between Hemoglobin Level and Intellectual Function.

    Munro, Nancy

    In a study to learn whether or not poor nutrition, as indicated by low hemoglobin levels, affects intelligence and behavior, 113 Head Start children in Missoula, Montana took part. Group testing with the Lorge Thorndike Intelligence Test and individual testing with the Wechsler and Primary Scale of Intelligence or Wechsler Intelligence Scale for…

  4. Human macrophage hemoglobin-iron metabolism in vitro

    Custer, G.; Balcerzak, S.; Rinehart, J.

    1982-01-01

    An entirely in vitro technique was employed to characterize hemoglobin-iron metabolism by human macrophages obtained by culture of blood monocytes and pulmonary alveolar macrophages. Macrophages phagocytized about three times as many erythrocytes as monocytes and six times as many erythrocytes as pulmonary alveolar macrophages. The rate of subsequent release of 59 Fe to the extracellular transferrin pool was two- to fourfold greater for macrophages as compared to the other two cell types. The kinetics of 59 Fe-transferrin release were characterized by a relatively rapid early phase (hours 1-4) followed by a slow phase (hours 4-72) for all three cell types. Intracellular movement of iron was characterized by a rapid shift from hemoglobin to ferritin that was complete with the onset of the slow phase of extracellular release. A transient increase in 59 Fe associated with an intracellular protein eluting with transferrin was also observed within 1 hour after phagocytosis. The process of hemoglobin-iron release to extracellular transferrin was inhibited at 4 degrees C but was unaffected by inhibitory of protein synthesis, glycolysis, microtubule function, and microfilament function. These data emphasize the rapidity of macrophage hemoglobin iron metabolism, provide a model for characterization of this process in vitro, and in general confirm data obtained utilizing in vivo animal models

  5. Randomized Controlled Trial of Electronic Care Plan Alerts and Resource Utilization by High Frequency Emergency Department Users with Opioid Use Disorder

    Niels Rathlev, MD

    2016-01-01

    Full Text Available Introduction: There is a paucity of literature supporting the use of electronic alerts for patients with high frequency emergency department (ED use. We sought to measure changes in opioid prescribing and administration practices, total charges and other resource utilization using electronic alerts to notify providers of an opioid-use care plan for high frequency ED patients. Methods: This was a randomized, non-blinded, two-group parallel design study of patients who had 1 opioid use disorder and 2 high frequency ED use. Three affiliated hospitals with identical electronic health records participated. Patients were randomized into “Care Plan” versus “Usual Care groups”. Between the years before and after randomization, we compared as primary outcomes the following: 1 opioids (morphine mg equivalents prescribed to patients upon discharge and administered to ED and inpatients; 2 total medical charges, and the numbers of; 3 ED visits, 4 ED visits with advanced radiologic imaging (computed tomography [CT] or magnetic resonance imaging [MRI] studies, and 5 inpatient admissions. Results: A total of 40 patients were enrolled. For ED and inpatients in the “Usual Care” group, the proportion of morphine mg equivalents received in the post-period compared with the pre-period was 15.7%, while in the “Care Plan” group the proportion received in the post-period compared with the pre-period was 4.5% (ratio=0.29, 95% CI [0.07-1.12]; p=0.07. For discharged patients in the “Usual Care” group, the proportion of morphine mg equivalents prescribed in the post-period compared with the pre-period was 25.7% while in the “Care Plan” group, the proportion prescribed in the post-period compared to the pre-period was 2.9%. The “Care Plan” group showed an 89% greater proportional change over the periods compared with the “Usual Care” group (ratio=0.11, 95% CI [0.01-0.092]; p=0.04. Care plans did not change the total charges, or, the numbers

  6. The subunit structure of the extracellular hemoglobin of Biomphalaria glabrata

    Arndt, Marcio H.L.; Naves, Cristiani F.; Xavier, Luciana P.; Santoro, Marcelo M.

    1997-01-01

    Full text. The hemoglobin of Biomphalaria glabrata was purified to homogeneity by a two step purification protocol using a gel filtration column (Superose 6 HR/Pharmacia ) followed by an anion exchange chromatography (MONO-Q Sepharose/Pharmacia). The dissociation products were analysed by a 5 - 15 % Polyacrylamide gel electrophoresis containing Sodium Dodecyl Sulfate (SDS-PAGE) giving a band of 270 K Daltons and a band of 180 K Daltons after reduction with β-mercaptoethanol. The same profile was obtained in a 3.5 % Agarose gel electrophoresis containing SDS (SDS-AGE) showing additional bands of higher molecular weight. These bands were proposed to be monomers, dimers and trimers and, after reduction in a Bidimensional SDS-AGE, the proposed monomers and dimers were decomposed in two and four bands that were interpreted as 1 - 4 chains. The hemoglobin was digested by four different proteases ( Thrombin, Trypsin, Chymotrypsin and Subtilisin ) showing several equivalent fragments with molecular weights multiples of its minimum molecular weight ( 17.7 K Daltons). The circular dichroism spectrum of the protein showed a characteristic high α-helix content. We proposed that this hemoglobin is a pentamer of approx. 360 K Daltons subunits each formed by two 180 K Daltons chains linked in pairs by disulfide bridges and each of these chains comprises ten Heme binding domains. These data were compared to other Planorbidae extracellular hemoglobins. Up to now, the quaternary structure of this hemoglobin (shape and disposition of the subunits) is unknown. It is intended to elucidate its structure by Small Angle X-Ray Scattering in Brazilian National Laboratory of Synchrotron Light (LNLS). (author)

  7. Hemoglobin Kinetics and Long-term Prognosis in Heart Failure.

    Díez-López, Carles; Lupón, Josep; de Antonio, Marta; Zamora, Elisabet; Domingo, Mar; Santesmases, Javier; Troya, Maria-Isabel; Boldó, Maria; Bayes-Genis, Antoni

    2016-09-01

    The influence of hemoglobin kinetics on outcomes in heart failure has been incompletely established. Hemoglobin was determined at the first visit and at 6 months. Anemia was defined according to World Health Organization criteria (hemoglobin < 13g/dL for men and hemoglobin < 12g/dL for women). Patients were classified relative to their hemoglobin values as nonanemic (both measurements normal), transiently anemic (anemic at the first visit but not at 6 months), newly anemic (nonanemic initially but anemic at 6 months), or permanently anemic (anemic in both measurements). A total of 1173 consecutive patients (71.9% men, mean age 66.8±12.2 years) were included in the study. In all, 476 patients (40.6%) were considered nonanemic, 170 (14.5%) had transient anemia, 147 (12.5%) developed new-onset anemia, and 380 (32.4%) were persistently anemic. During a follow-up of 3.7±2.8 years after the 6-month visit, 494 patients died. On comprehensive multivariable analyses, anemia (P < .001) and the type of anemia (P < .001) remained as independent predictors of all-cause mortality. Compared with patients without anemia, patients with persistent anemia (hazard ratio [HR] = 1.62; 95% confidence interval [95%CI], 1.30-2.03; P < .001) and new-onset anemia (HR = 1.39; 95%CI, 1.04-1.87, P = .03) had higher mortality, and even transient anemia showed a similar trend, although without reaching statistical significance (HR = 1.31; 95%CI, 0.97-1.77, P = .075). Anemia, especially persistent and of new-onset, and to a lesser degree, transient anemia, is deleterious in heart failure. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  8. Anemia and hemoglobin levels among Indigenous Xavante children, Central Brazil.

    Ferreira, Aline Alves; Santos, Ricardo Ventura; Souza, July Anne Mendonça de; Welch, James R; Coimbra, Carlos E A

    2017-01-01

    To evaluate the prevalence of anemia, mean hemoglobin levels, and the main nutritional, demographic, and socioeconomic factors among Xavante children in Mato Grosso State, Brazil. A survey was conducted with children under 10 years of age in two indigenous Xavante communities within the Pimentel Barbosa Indigenous Reserve. Hemoglobin concentration levels, anthropometric measurements, and socioeconomic/demographic data were collected by means of clinical measurements and structured interviews. The cut-off points recommended by the World Health Organization were used for anemia classification. Linear regression analyses with hemoglobin as the outcome and Poisson regression with robust variance and with the presence or absence of anemia as outcomes were performed (95%CI). Lower mean hemoglobin values were observed in children under 2 years of age, without a significant difference between sexes. Anemia was observed among 50.8% of children overall, with the highest prevalence among children under 2 years of age (77.8%). Age of the child was inversely associated with the occurrence of anemia (adjusted PR = 0.60; 95%CI 0.38-0.95) and mean hemoglobin values increased significantly with age. Greater height-for-age z-score values reduced the probability of having anemia by 1.8 times (adjusted PR = 0.59; 95%CI 0.34-1.00). Presence of another child with anemia within the household increased the probability of the occurrence of anemia by 52.9% (adjusted PR = 1.89; 95%CI 1.16-3.09). Elevated levels of anemia among Xavante children reveal a disparity between this Indigenous population and the national Brazilian population. Results suggest that anemia is determined by complex and variable relationships between socioeconomic, sociodemographic, and biological factors.

  9. There is a Relationship between Resource Expenditures and Reference Transactions in Academic Libraries. A Review of: Dubnjakovic, A. (2012. Electronic resource expenditure and the decline in reference transaction statistics in academic libraries. Journal of Academic Librarianship, 38(2, 94-100. doi:10.1016/j.acalib.2012.01.001

    Annie M. Hughes

    2013-03-01

    Full Text Available Objective – To provide an analysis of the impact of expenditures on electronic resourcesand gate counts on the increase or decrease in reference transactions.Design – Analysis of results of existing survey data from the National Center for Educational Statistics (NCES 2006 Academic Library Survey(ALS.Setting – Academic libraries in the United States.Subjects – 3925 academic library respondents.Methods – The author chose to use survey data collected from the 2006 ALS conducted bythe NCES. The survey included data on various topics related to academic libraries, but in the case of this study, the author chose to analyze three of the 193 variables included. The three variables: electronic books expenditure, computer hardware and software, and expenditures on bibliographic utilities, were combined into one variable called electronic resource expenditure. Gate counts were also considered as a variable. Electronic resource expenditure was also split as a variable into three groups: low, medium, and high. Multiple regression analysis and general linear modeling, along with tests of reliability, were employed. Main Results – The author determined that low, medium, and high spenders with regard to electronic resources exhibited differences in gate counts, and gate counts have an effect on reference transactions in any given week. Gate counts tend to not have much of an effect on reference transactions for the higher spenders, and higher spenders tend to have a higher number of reference transactions overall. Low spenders have lower gate counts and also a lower amount of reference transactions.Conclusion – The findings from this study show that academic libraries spending more on electronic resources also tend to have an increase with regard to reference transactions. The author also concludes that library spaces are no longer the determining factor with regard to number of reference transactions. Spending more on electronic resources is

  10. X-ray diffraction study of the binding of the antisickling agent 12C79 to human hemoglobin

    Wireko, R.C.; Abraham, D.J.

    1991-01-01

    The hemoglobin binding site of the antisickling agent 12C79 has been determined by x-ray crystallography. 12C79 is recognized as one of the first molecules to reach clinical trials that was designed, de novo, from x-ray-determined atomic coordinates of a protein. Several previous attempts to verify the proposed Hb binding sites via crystallographic studies have failed. Using revised experimental procedures, the authors obtained 12C79-deoxhemoglobin crystals grown after reaction with oxyhemoglobin and cyanoborohydride reduction to stabilize the Schiff base linkage. The difference electron-density Fourier maps show that two 12C79 molecules bind covalently to both symmetry-related N-terminal amino groups of the hemoglobin α chains. This is in contrast to the original design that proposed the binding of one drug molecule that spans the molecular dyad to interact with both N-terminal α-amino groups

  11. Genetic hemoglobin disorders rather than iron deficiency are a major predictor of hemoglobin concentration in women of reproductive age in rural prey Veng, Cambodia.

    Karakochuk, Crystal D; Whitfield, Kyly C; Barr, Susan I; Lamers, Yvonne; Devlin, Angela M; Vercauteren, Suzanne M; Kroeun, Hou; Talukder, Aminuzzaman; McLean, Judy; Green, Timothy J

    2015-01-01

    Anemia is common in Cambodian women. Potential causes include micronutrient deficiencies, genetic hemoglobin disorders, inflammation, and disease. We aimed to investigate factors associated with anemia (low hemoglobin concentration) in rural Cambodian women (18-45 y) and to investigate the relations between hemoglobin disorders and other iron biomarkers. Blood samples were obtained from 450 women. A complete blood count was conducted, and serum and plasma were analyzed for ferritin, soluble transferrin receptor (sTfR), folate, vitamin B-12, retinol binding protein (RBP), C-reactive protein (CRP), and α1 acid glycoprotein (AGP). Hemoglobin electrophoresis and multiplex polymerase chain reaction were used to determine the prevalence and type of genetic hemoglobin disorders. Overall, 54% of women had a genetic hemoglobin disorder, which included 25 different genotypes (most commonly, hemoglobin E variants and α(3.7)-thalassemia). Of the 420 nonpregnant women, 29.5% had anemia (hemoglobin 8.3 mg/L), hemoglobin disorders, respectively. There was no biochemical evidence of vitamin A deficiency (RBP 5 mg/L) and 26% (AGP >1 g/L) of nonpregnant women, respectively. By using an adjusted linear regression model, the strongest predictors of hemoglobin concentration were hemoglobin E homozygous disorder and pregnancy status. Other predictors were 2 other heterozygous traits (hemoglobin E and Constant Spring), parity, RBP, log ferritin, and vitamin B-12. Multiple biomarkers for anemia and iron deficiency were significantly influenced by the presence of hemoglobin disorders, hence reducing their diagnostic sensitivity. Further investigation of the unexpectedly low prevalence of IDA in Cambodian women is warranted. © 2015 American Society for Nutrition.

  12. Global application of disorders of sex development-related electronic resources: e-learning, e-consultation and e-information sharing.

    Muscarella, Miriam; Kranenburg-van Koppen, Laura; Grijpink-van den Biggelaar, Kalinka; Drop, Stenvert L S

    2014-01-01

    The past 20 years have seen proliferation of electronic (e) resources that promote improved understanding of disorders of sex development (DSD): e-learning for physicians and trainees, e-consultation between clinicians, and e-information for families and affected individuals. Recent e-learning advances have emerged from the European Society for Pediatric Endocrinology's online learning portal for current physicians and trainees. Developed with attention to developing clinical competencies incorporating learning theory, and presenting material that represents international best practice, this e-learning portal offers advances in training, making information more accessible for clinicians and trainees. Multiple levels of instruction, authentic case examples, collaborative forums for physicians and trainees, individualized feedback and user-friendly tools represent advances in trainee and physician learning that can take place in any location. e-consultation is an emerging tool that aims to connect physicians with specialists experienced in DSD care. Although it faces logistical challenges, e-consultation carries the potential to improve DSD care, especially in remote areas with limited access to DSD specialists. e-information for families and patients of all ages is widely accessible online, often with focus on DSD biology, medical care, and psychological and social support. e-information tools aid self-management and support of those affected by DSD. Efforts to improve these resources should aim to map information to individual users, incorporate optimally clear nomenclature, and continue as a 'shared enterprise' of clinicians, affected individuals, families and researchers. Improving the quality of DSD-related e-learning and e-information and developing e-consultation carries the potential to transform DSD care and support for patients, families and physicians worldwide. © 2014 S. Karger AG, Basel.

  13. FET immunosensor for hemoglobin A1c using a gold nanofilm grown by a seed-mediated technique and covered with mixed self-assembled monolayers

    Xue, Q.; Bian, C.; Tong, J.; Sun, J.; Zhang, H.; Xia, S.

    2012-01-01

    A micro FET-based immunosensor was developed for the determination of hemoglobin-A1c (HbA1c). The HbA1c/hemoglobin ratio is an important index in diabetes control. The sensor was fabricated by Complementary Metal-Oxide-Semiconductor Transistor (CMOS) and Micro Electronic Mechanical System (MEMS) techniques. The antibodies were immobilized via mixed self-assembled monolayers (SAMs) on a gold nanofilm. The nanofilm was deposited on a gold electrode by seed-mediated growth and gave a uniform and well distributed coverage. Nonspecific sites and interferences by noise were eliminated by covering the AuNPs with mixed SAMs. Compared to the immunosensor fabricated via the mixed SAMs method without gold nanofilm, the immunosensor displays a more than 2-fold sensitivity. The immunosensor is capable of detecting HbA1c and hemoglobin in hemolyzed and diluted whole blood, and results showed good agreement with the established clinical method. (author)

  14. MR Imaging-derived Oxygen-Hemoglobin Dissociation Curves and Fetal-Placental Oxygen-Hemoglobin Affinities.

    Avni, Reut; Golani, Ofra; Akselrod-Ballin, Ayelet; Cohen, Yonni; Biton, Inbal; Garbow, Joel R; Neeman, Michal

    2016-07-01

    Purpose To generate magnetic resonance (MR) imaging-derived, oxygen-hemoglobin dissociation curves and to map fetal-placental oxygen-hemoglobin affinity in pregnant mice noninvasively by combining blood oxygen level-dependent (BOLD) T2* and oxygen-weighted T1 contrast mechanisms under different respiration challenges. Materials and Methods All procedures were approved by the Weizmann Institutional Animal Care and Use Committee. Pregnant mice were analyzed with MR imaging at 9.4 T on embryonic days 14.5 (eight dams and 58 fetuses; imprinting control region ICR strain) and 17.5 (21 dams and 158 fetuses) under respiration challenges ranging from hyperoxia to hypoxia (10 levels of oxygenation, 100%-10%; total imaging time, 100 minutes). A shorter protocol with normoxia to hyperoxia was also performed (five levels of oxygenation, 20%-100%; total imaging time, 60 minutes). Fast spin-echo anatomic images were obtained, followed by sequential acquisition of three-dimensional gradient-echo T2*- and T1-weighted images. Automated registration was applied to align regions of interest of the entire placenta, fetal liver, and maternal liver. Results were compared by using a two-tailed unpaired Student t test. R1 and R2* values were derived for each tissue. MR imaging-based oxygen-hemoglobin dissociation curves were constructed by nonlinear least square fitting of 1 minus the change in R2*divided by R2*at baseline as a function of R1 to a sigmoid-shaped curve. The apparent P50 (oxygen tension at which hemoglobin is 50% saturated) value was derived from the curves, calculated as the R1 scaled value (x) at which the change in R2* divided by R2*at baseline scaled (y) equals 0.5. Results The apparent P50 values were significantly lower in fetal liver than in maternal liver for both gestation stages (day 14.5: 21% ± 5 [P = .04] and day 17.5: 41% ± 7 [P hemoglobin dissociation curves with a shorter protocol that excluded the hypoxic periods was demonstrated. Conclusion MR imaging

  15. Ranking Medical Terms to Support Expansion of Lay Language Resources for Patient Comprehension of Electronic Health Record Notes: Adapted Distant Supervision Approach.

    Chen, Jinying; Jagannatha, Abhyuday N; Fodeh, Samah J; Yu, Hong

    2017-10-31

    Medical terms are a major obstacle for patients to comprehend their electronic health record (EHR) notes. Clinical natural language processing (NLP) systems that link EHR terms to lay terms or definitions allow patients to easily access helpful information when reading through their EHR notes, and have shown to improve patient EHR comprehension. However, high-quality lay language resources for EHR terms are very limited in the public domain. Because expanding and curating such a resource is a costly process, it is beneficial and even necessary to identify terms important for patient EHR comprehension first. We aimed to develop an NLP system, called adapted distant supervision (ADS), to rank candidate terms mined from EHR corpora. We will give EHR terms ranked as high by ADS a higher priority for lay language annotation-that is, creating lay definitions for these terms. Adapted distant supervision uses distant supervision from consumer health vocabulary and transfer learning to adapt itself to solve the problem of ranking EHR terms in the target domain. We investigated 2 state-of-the-art transfer learning algorithms (ie, feature space augmentation and supervised distant supervision) and designed 5 types of learning features, including distributed word representations learned from large EHR data for ADS. For evaluating ADS, we asked domain experts to annotate 6038 candidate terms as important or nonimportant for EHR comprehension. We then randomly divided these data into the target-domain training data (1000 examples) and the evaluation data (5038 examples). We compared ADS with 2 strong baselines, including standard supervised learning, on the evaluation data. The ADS system using feature space augmentation achieved the best average precision, 0.850, on the evaluation set when using 1000 target-domain training examples. The ADS system using supervised distant supervision achieved the best average precision, 0.819, on the evaluation set when using only 100 target

  16. Changes in the Conformational State of Hemoglobin in Hemodialysed Patients with Chronic Renal Failure

    Anna Pieniazek

    2015-01-01

    Full Text Available The aim of this study was to evaluate the properties of internal components of erythrocytes in chronic renal failure (CRF patients undergoing hemodialysis (HD in comparison to control subjects. For investigation of conformational state of hemoglobin and nonheme proteins (NHP the maleimide spin label (MSL in electron paramagnetic resonance (EPR was applied. The studies were performed using MSL in whole cells and hemolysate as well as proteins separated by ion exchange chromatography and checked by electrophoresis. Additionally the level of –SH groups in hemolysate and isolated internal proteins of CRF erythrocytes was determined using 4,4′-dithiodipyridine. All measurements were performed before and after hemodialysis. Oxidative stress accompanying CRF/hemodialysed patients caused a significant decrease in the mobility of internal components inside erythrocytes indicated by MSL (P < 0.02. The significant decrease in mobility of spin labeled HbA1c and HbA both before and after HD (P < 0.0002 as well as in nonheme proteins before hemodialysis (P < 0.05 versus control was indicated. Decrease in mobility of internal components of erythrocytes was accompanied by loss of thiols before and after hemodialysis versus control in NHP (P < 0.05, HbA1c (P < 0.0002, and HbA (P < 0.0005. These findings showed oxidative influence of hemodialysis on hemoglobins and internal nonheme proteins in erythrocytes of CRF patients.

  17. Biocompatibility study of protein capped and uncapped silver nanoparticles on human hemoglobin

    Bhunia, Amit Kumar; Kanti Samanta, Pijus; Aich, Debasish; Saha, Satyajit; Kamilya, Tapanendu

    2015-06-01

    The interactions of human hemoglobin with protein capped silver nanoparticles and bare silver nanoparticles were studied to understand fundamental perspectives about the biocompatibility of protein capped silver nanoparticles compared with bare silver nanoparticles. Bare silver (Ag) nanoparticles (NPs) were prepared by the chemical reduction method. High resolution transmission electron microscopy (HRTEM) analysis along with absorption at ~390 nm indicated the formation of bare Ag NPs. Protein coated Ag NPs were prepared by a green synthesis method. Absorption at ~440 nm along with ~280 nm indicated the formation of protein coated Ag NPs. The biocompatibility of the above mentioned Ag NPs was studied by interaction with human hemoglobin (Hb) protein. In presence of bare Ag NPs, the Soret band of Hb was red shifted. This revealed the distortion of iron from the heme pockets of Hb. Also, the fluorescence peak of Hb was quenched and red shifted which indicated that Hb became unfolded in the presence of bare Ag NPs. No red shift of the absorption of Soret, along with no shift and quenching of the fluorescence peak of Hb were observed in the presence of protein coated Ag NPs. A hemolysis assay suggested that protein coated Ag NPs were more biocompatible than bare one.

  18. Nanomolar detection of methylparaben by a cost-effective hemoglobin-based biosensor.

    Hajian, A; Ghodsi, J; Afraz, A; Yurchenko, O; Urban, G

    2016-12-01

    This work describes the development of a new biosensor for methylparaben determination using electrocatalytic properties of hemoglobin in the presence of hydrogen peroxide. The voltammetric oxidation of methylparaben by the proposed biosensor in phosphate buffer (pH=7.0), a physiological pH, was studied and it was confirmed that methylparaben undergoes a one electron-one proton reaction in a diffusion-controlled process. The biosensor was fabricated by carbon paste electrode modified with hemoglobin and multiwalled carbon nanotube. Based on the excellent electrochemical properties of the modified electrode, a sensitive voltammetric method was used for determination of methylparaben within a linear range from 0.1 to 13μmolL(-1) and detection limit of 25nmolL(-1). The developed biosensor possessed accurate and rapid response to methylparaben and showed good sensitivity, stability, and repeatability. Finally, the applicability of the proposed biosensor was verified by methylparaben evaluation in various real samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Changes in the Conformational State of Hemoglobin in Hemodialysed Patients with Chronic Renal Failure

    Pieniazek, Anna; Gwozdzinski, Krzysztof

    2015-01-01

    The aim of this study was to evaluate the properties of internal components of erythrocytes in chronic renal failure (CRF) patients undergoing hemodialysis (HD) in comparison to control subjects. For investigation of conformational state of hemoglobin and nonheme proteins (NHP) the maleimide spin label (MSL) in electron paramagnetic resonance (EPR) was applied. The studies were performed using MSL in whole cells and hemolysate as well as proteins separated by ion exchange chromatography and checked by electrophoresis. Additionally the level of –SH groups in hemolysate and isolated internal proteins of CRF erythrocytes was determined using 4,4′-dithiodipyridine. All measurements were performed before and after hemodialysis. Oxidative stress accompanying CRF/hemodialysed patients caused a significant decrease in the mobility of internal components inside erythrocytes indicated by MSL (P < 0.02). The significant decrease in mobility of spin labeled HbA1c and HbA both before and after HD (P < 0.0002) as well as in nonheme proteins before hemodialysis (P < 0.05) versus control was indicated. Decrease in mobility of internal components of erythrocytes was accompanied by loss of thiols before and after hemodialysis versus control in NHP (P < 0.05), HbA1c (P < 0.0002), and HbA (P < 0.0005). These findings showed oxidative influence of hemodialysis on hemoglobins and internal nonheme proteins in erythrocytes of CRF patients. PMID:25866600

  20. Crystal structure of hemoglobin from the maned wolf (Chrysocyon brachyurus) using synchrotron radiation.

    Fadel, Valmir; Canduri, Fernanda; Olivieri, Johnny R; Smarra, André L S; Colombo, Marcio F; Bonilla-Rodriguez, Gustavo O; de Azevedo, Walter F

    2003-12-01

    Crystal structure of hemoglobin isolated from the Brazilian maned wolf (Chrysocyon brachyurus) was determined using standard molecular replacement technique and refined using maximum-likelihood and simulated annealing protocols to 1.87A resolution. Structural and functional comparisons between hemoglobins from the Chrysocyon brachyurus and Homo sapiens are discussed, in order to provide further insights in the comparative biochemistry of vertebrate hemoglobins.

  1. Hemoglobin A1c (HbA1c) Test: MedlinePlus Lab Test Information

    ... page: https://medlineplus.gov/labtests/hemoglobina1chba1ctest.html Hemoglobin A1c (HbA1c) Test To use the sharing features on this page, please enable JavaScript. What is a hemoglobin A1c (HbA1c) test? A hemoglobin A1c (HbA1c) test measures ...

  2. Hemoglobin levels in persons with depressive and/or anxiety disorders

    Lever-van Milligen, Bianca A.; Vogelzangs, Nicole; Smit, Johannes H.; Penninx, Brenda W. J. H.

    Objective: Both low and high hemoglobin levels lead to more physical diseases, and both are linked to mortality. Low hemoglobin, often classified as anemia, has also been linked to more depressive symptoms, but whether both hemoglobin extremes are associated with depressive disorder and potentially

  3. Impact of two interventions on timeliness and data quality of an electronic disease surveillance system in a resource limited setting (Peru: a prospective evaluation

    Quispe Jose A

    2009-03-01

    Full Text Available Abstract Background A timely detection of outbreaks through surveillance is needed in order to prevent future pandemics. However, current surveillance systems may not be prepared to accomplish this goal, especially in resource limited settings. As data quality and timeliness are attributes that improve outbreak detection capacity, we assessed the effect of two interventions on such attributes in Alerta, an electronic disease surveillance system in the Peruvian Navy. Methods 40 Alerta reporting units (18 clinics and 22 ships were included in a 12-week prospective evaluation project. After a short refresher course on the notification process, units were randomly assigned to either a phone, visit or control group. Phone group sites were called three hours before the biweekly reporting deadline if they had not sent their report. Visit group sites received supervision visits on weeks 4 & 8, but no phone calls. The control group sites were not contacted by phone or visited. Timeliness and data quality were assessed by calculating the percentage of reports sent on time and percentage of errors per total number of reports, respectively. Results Timeliness improved in the phone group from 64.6% to 84% in clinics (+19.4 [95% CI, +10.3 to +28.6]; p Conclusion Regular phone reminders significantly improved timeliness of reports in clinics and ships, whereas supervision visits led to improved data quality only among clinics. Further investigations are needed to establish the cost-effectiveness and optimal use of each of these strategies.

  4. TECHNIQUES OF EVALUATION OF HEMOGLOBIN OXYGEN SATURATION IN CLINICAL OPHTHALMOLOGY

    S. Yu. Petrov

    2016-01-01

    Full Text Available Oxygen content in body fluids and tissues is an important indicator of life support functions. A number of ocular pathologies, e.g. glaucoma, are of presumable vascular origin which means altered blood supply and oxygen circulation. Most oxygen is transported in the blood in the association with hemoglobin. When passing through the capillaries, hemoglobin releases oxygen, converting from oxygenated form to deoxygenated form. This process is accompanied by the changes in spectral characteristics of hemoglobin which result in different colors of arterial and venous blood. Photometric technique for the measurement of oxygen saturation in blood is based on the differences in light absorption by different forms of hemoglobin. The measurement of saturation is called oximetry. Pulse oximetry with assessment of tissue oxygenation is the most commonly used method in medicine. The degree of hemoglobin oxygen saturation in the eye blood vessels is the most accessible for noninvasive studies during ophthalmoscopy and informative. Numerous studies showed the importance of this parameter for the diagnosis of retinopathy of various genesis, metabolic status analysis in hyperglycemia, diagnosis and control of treatment of glaucoma and other diseases involving alterations in eye blood supply. The specific method for evaluation of oxygen concentration is the measurement of pressure of oxygen dissolved in the blood, i.e. partial pressure of oxygen. In ophthalmological practice, this parameter is measured in anterior chamber fluid evaluating oxygen level for several ophthalmopathies including different forms of glaucoma, for instillations of hypotensive eye drops as well as in vitreous body near to the optic disc under various levels of intraocular pressure. Currently, monitoring of oxygen saturation in retinal blood vessels, i.e. retinal oximetry, is well developed. This technique is based on the assessment of light absorption by blood depending on

  5. Evaluation of non cyanide methods for hemoglobin estimation

    Vinaya B Shah

    2011-01-01

    Full Text Available Background: The hemoglobincyanide method (HiCN method for measuring hemoglobin is used extensively worldwide; its advantages are the ready availability of a stable and internationally accepted reference standard calibrator. However, its use may create a problem, as the waste disposal of large volumes of reagent containing cyanide constitutes a potential toxic hazard. Aims and Objective: As an alternative to drabkin`s method of Hb estimation, we attempted to estimate hemoglobin by other non-cyanide methods: alkaline hematin detergent (AHD-575 using Triton X-100 as lyser and alkaline- borax method using quarternary ammonium detergents as lyser. Materials and Methods: The hemoglobin (Hb results on 200 samples of varying Hb concentrations obtained by these two cyanide free methods were compared with a cyanmethemoglobin method on a colorimeter which is light emitting diode (LED based. Hemoglobin was also estimated in one hundred blood donors and 25 blood samples of infants and compared by these methods. Statistical analysis used was Pearson`s correlation coefficient. Results: The response of the non cyanide method is linear for serially diluted blood samples over the Hb concentration range from 3gm/dl -20 gm/dl. The non cyanide methods has a precision of + 0.25g/dl (coefficient of variation= (2.34% and is suitable for use with fixed wavelength or with colorimeters at wavelength- 530 nm and 580 nm. Correlation of these two methods was excellent (r=0.98. The evaluation has shown it to be as reliable and reproducible as HiCN for measuring hemoglobin at all concentrations. The reagents used in non cyanide methods are non-biohazardous and did not affect the reliability of data determination and also the cost was less than HiCN method. Conclusions: Thus, non cyanide methods of Hb estimation offer possibility of safe and quality Hb estimation and should prove useful for routine laboratory use. Non cyanide methods is easily incorporated in hemobloginometers

  6. Patterns of glycemic control using glycosylated hemoglobin in diabetics

    Arunpreet Singh Kahlon

    2011-01-01

    Full Text Available Aim : Till now estimation of blood glucose is the highly effective method for diagnosing diabetes mellitus but it provides a short-term picture of control. More evidence is required to prove that plasma glucose and glycosylated hemoglobin levels together gives a better estimate of glycemic control and compliance with treatment. Indian diabetes risk score (IDRS is a simplified screening tool for identifying undiagnosed diabetic subjects, requires minimum time, and effort and can help to considerably reduce the costs of screening. Objective : To study patterns of glycemic control using glycosylated hemoglobin in diabetic patients. To find out correlation between levels of plasma glucose and glycosylated hemoglobin in diabetics and to calculate IDRS of the study population. Materials and Methods : A cross sectional study was conducted among 300 known diabetic patients attending outpatient department of a rural medical college in Haryana, India. Following standard procedures and protocols FPG and glycosylated hemoglobin were measured to find out a pattern of glycemic control in them after taking their written and informed consent. A correlation between the levels of glycosylated hemoglobin and fasting blood glucose was also calculated. These patients were made to fill a performa and their demographic and clinical risk factors were noted and based on this, their IDRS was calculated. This was done to validate the IDRS in Indian rural population. Results : Fifty-two percent of the population had fasting plasma glucose level between 125-150 mg/dl, 21% had this level between 151-175 mg/dl. Thirteen percent of the study subjects had HbA1C between 6.5-7.5, more than half (57.3% had this value between 7.5-8.5, 12% and 18% had values between 8.5-9.5 and 9.5-10.5, respectively. Twelve percent of the participants had HbA1C level higher than 10.5. Correlation of fasting plasma glucose level and HbA1C was also studied and found that correlation coefficient came

  7. Patterns of glycemic control using glycosylated hemoglobin in diabetics.

    Kahlon, Arunpreet Singh; Pathak, Rambha

    2011-07-01

    Till now estimation of blood glucose is the highly effective method for diagnosing diabetes mellitus but it provides a short-term picture of control. More evidence is required to prove that plasma glucose and glycosylated hemoglobin levels together gives a better estimate of glycemic control and compliance with treatment. Indian diabetes risk score (IDRS) is a simplified screening tool for identifying undiagnosed diabetic subjects, requires minimum time, and effort and can help to considerably reduce the costs of screening. To study patterns of glycemic control using glycosylated hemoglobin in diabetic patients. To find out correlation between levels of plasma glucose and glycosylated hemoglobin in diabetics and to calculate IDRS of the study population. A cross sectional study was conducted among 300 known diabetic patients attending outpatient department of a rural medical college in Haryana, India. Following standard procedures and protocols FPG and glycosylated hemoglobin were measured to find out a pattern of glycemic control in them after taking their written and informed consent. A correlation between the levels of glycosylated hemoglobin and fasting blood glucose was also calculated. These patients were made to fill a performa and their demographic and clinical risk factors were noted and based on this, their IDRS was calculated. This was done to validate the IDRS in Indian rural population. Fifty-two percent of the population had fasting plasma glucose level between 125-150 mg/dl, 21% had this level between 151-175 mg/dl. Thirteen percent of the study subjects had HbA1C between 6.5-7.5, more than half (57.3%) had this value between 7.5-8.5, 12% and 18% had values between 8.5-9.5 and 9.5-10.5, respectively. Twelve percent of the participants had HbA1C level higher than 10.5. Correlation of fasting plasma glucose level and HbA1C was also studied and found that correlation coefficient came out to be .311. This correlation was found to be statistically

  8. Vitreoscilla hemoglobin promotes Salecan production by Agrobacterium sp. ZX09.

    Chen, Yun-mei; Xu, Hai-yang; Wang, Yang; Zhang, Jian-fa; Wang, Shi-ming

    2014-11-01

    Salecan is a novel exopolysaccharide produced by the strain Agrobacterium sp. ZX09, and it is composed of only glucose monomers. The unique chemical composition and excellent physicochemical properties make Salecan a promising material for applications in coagulation, lubrication, protection against acute liver injury, and alleviating constipation. In this study, we cloned the Vitreoscilla hemoglobin gene into a broad-host-range plasmid pCM158. Without antibiotic selection, there was negligible loss of the plasmid in the host Agrobacterium sp. ZX09 after one passage of cultivation. The expression of Vitreoscilla hemoglobin was demonstrated by carbon monoxide (CO) difference spectrum. The engineered strain Agrobacterium sp. ZX09 increased Salecan yield by 30%. The other physiological changes included its elevated respiration rate and cellular invertase activity.

  9. Hemoglobin concentrations and associated factors in adolescentes from Recife, Brazil

    Elisângela Barros Soares Mendonça

    2014-10-01

    Full Text Available OBJECTIVE: To estimate the prevalence of anemia and associated factors in adolescents from the city of Recife in Pernambuco state. METHODS: This is a cross-sectional study, involving a random sample of 256 adolescents of both genders, aged 13 to 18, whose hemoglobin concentrations were evaluated, along with their nutritional status and socioeconomic and demographic characteristics. RESULTS: The prevalence of inadequate hemoglobin concentrations was 10.2% [CI95%=6.7-14.5], reaching levels considered as mild anemia (9 g/dL 0.05, nor with socioeconomic or demographic characteristics (p>0.05. CONCLUSION: Although the prevalence of anemia was low and classified as a mild health problem, preventive nutrition education involving the dissemination of healthy eating habits in schools and encouraging the consumption of iron-rich foods are strongly recommended.

  10. Reticulocyte hemoglobin content (MCHr) in the detection of iron deficiency.

    Urrechaga Igartua, Eloísa; Hoffmann, Johannes J M L; Izquierdo-Álvarez, Silvia; Escanero, Jesús F

    2017-09-01

    Blood hemoglobin (Hb) concentration within the reference interval does not exclude iron deficiency (ID): individuals with normal stores lose iron during a long period before their Hb falls below of the level that is defined as anemia. The process entails a decrease of storage iron, shown by serum ferritin below reference range, followed by iron depletion, eventually leading to iron restricted erythropoiesis; consequence of an imbalance between erythropoietic iron requirements and too low supply is a reduction of Hb synthesis in reticulocytes. We study the potential utility of mean reticulocyte hemoglobin content (MCHr), reported by CELL-DYN Sapphire (Abbott Diagnostics) analyzer, in the detection of ID in non-anemic adults. 207 patients with Hb within the reference range were enrolled. ID was defined as Hb>120g/L (women), >130g/L (men) and serum ferritin iron deficient adults. Copyright © 2016 Elsevier GmbH. All rights reserved.

  11. Does Erythropoietin Cause Hemoglobin Variability- Is It ‘Normal’?

    Gupta, Ashwani K; David, Waseem

    2014-01-01

    Hemoglobin variability (Hb-var) in patients with chronic kidney disease has been stipulated to be a result of exogenous treatment with erythropoiesis stimulating agents (ESA) and has been related to mortality in dialysis patients. We hypothesized the existence of Hb-var independent of ESA administration and compared it to that in healthy adults using data from the Scripps-Kaiser and NHANES III databases. We studied the Hb-var in 1571 peritoneal dialysis patients which included 116 patients no...

  12. Optical Spectra of Hemoglobin Taken from Alcohol Dependent Humans

    Dudok K.; Dudok T.; Vlokh I.; Vlokh R.

    2005-01-01

    Optical spectra of CNMetHb and CNMetHb-Coomassi G-250, taken from the blood of humans with alcohol dependence, are studied in the spectral range of 450–750nm. The shifts in the spectral absorption maxima of CNMetHb-Coomassi G-250 complexes are observed for the diseased persons with alcohol dependence. The obtained results show that the hemoglobin structure of alcohol dependent humans is changed.

  13. Oxygenation properties and isoform diversity of snake hemoglobins

    Storz, Jay F.; Natarajan, Chandrasekhar; Moriyama, Hideaki

    2015-01-01

    Available data suggest that snake hemoglobins (Hbs) are characterized by a combination of unusual structural and functional properties relative to the Hbs of other amniote vertebrates, including oxygenation-linked tetramer- dimer dissociation. However, standardized comparative data are lacking fo...... isoform of the South American rattlesnake is homologous to the minor HbD of other amniotes and, contrary to the pattern of Hb isoform differentiation in birds and turtles, exhibits a lower O2 affinity than the HbA isoform....

  14. The Determinants of Hemoglobin Variability in Hemodialysis Patients

    Tomanoski Vasilije; Gjorgjievska Gordana; Zvezdakovska Jasminka; Krecova Vasiliki; Andonoski Aleksandar; Nakovska Margarita; Muharemi Serjat; Kliseski Tode; Janakievska Pavlina; Ristoska Katerina; Veliu Ramazan; Vasileva Liljana; Jovanov Toni; Mehmedi-Veseli Kaltrina; Ferati Beane

    2016-01-01

    Introduction. Factors that have been reported to affect erythropoietin (EPO) responsiveness in hemodialysis (HD) patients include iron deficiency, chronic inflammation, secondary hyperparathyroidism, malnutrition and inadequate HD dose. The aim of the study was to analyze the deteminants of hemoglobin variability in HD patients. Methods. The study encompassed 526 patients (197 F and 329 M). According to HD vintage at the beginning of the study the patients were divided into two groups: group-...

  15. Lower versus higher hemoglobin threshold for transfusion in septic shock.

    Holst, Lars B; Haase, Nicolai; Wetterslev, Jørn; Wernerman, Jan; Guttormsen, Anne B; Karlsson, Sari; Johansson, Pär I; Aneman, Anders; Vang, Marianne L; Winding, Robert; Nebrich, Lars; Nibro, Helle L; Rasmussen, Bodil S; Lauridsen, Johnny R M; Nielsen, Jane S; Oldner, Anders; Pettilä, Ville; Cronhjort, Maria B; Andersen, Lasse H; Pedersen, Ulf G; Reiter, Nanna; Wiis, Jørgen; White, Jonathan O; Russell, Lene; Thornberg, Klaus J; Hjortrup, Peter B; Müller, Rasmus G; Møller, Morten H; Steensen, Morten; Tjäder, Inga; Kilsand, Kristina; Odeberg-Wernerman, Suzanne; Sjøbø, Brit; Bundgaard, Helle; Thyø, Maria A; Lodahl, David; Mærkedahl, Rikke; Albeck, Carsten; Illum, Dorte; Kruse, Mary; Winkel, Per; Perner, Anders

    2014-10-09

    Blood transfusions are frequently given to patients with septic shock. However, the benefits and harms of different hemoglobin thresholds for transfusion have not been established. In this multicenter, parallel-group trial, we randomly assigned patients in the intensive care unit (ICU) who had septic shock and a hemoglobin concentration of 9 g per deciliter or less to receive 1 unit of leukoreduced red cells when the hemoglobin level was 7 g per deciliter or less (lower threshold) or when the level was 9 g per deciliter or less (higher threshold) during the ICU stay. The primary outcome measure was death by 90 days after randomization. We analyzed data from 998 of 1005 patients (99.3%) who underwent randomization. The two intervention groups had similar baseline characteristics. In the ICU, the lower-threshold group received a median of 1 unit of blood (interquartile range, 0 to 3) and the higher-threshold group received a median of 4 units (interquartile range, 2 to 7). At 90 days after randomization, 216 of 502 patients (43.0%) assigned to the lower-threshold group, as compared with 223 of 496 (45.0%) assigned to the higher-threshold group, had died (relative risk, 0.94; 95% confidence interval, 0.78 to 1.09; P=0.44). The results were similar in analyses adjusted for risk factors at baseline and in analyses of the per-protocol populations. The numbers of patients who had ischemic events, who had severe adverse reactions, and who required life support were similar in the two intervention groups. Among patients with septic shock, mortality at 90 days and rates of ischemic events and use of life support were similar among those assigned to blood transfusion at a higher hemoglobin threshold and those assigned to blood transfusion at a lower threshold; the latter group received fewer transfusions. (Funded by the Danish Strategic Research Council and others; TRISS ClinicalTrials.gov number, NCT01485315.).

  16. A retrospective study on fourteen year hemoglobin genotype ...

    This suggests the possibility of many other residents in the capital city of Ondo state carrying the abnormal forms of hemoglobin genotype, and calling for more efforts in the area of genetic counseling. The gene frequencies of A, S, and C were 0.91, 0.08 and 0.01, respectively. The prevalence of HbAA in this study has been ...

  17. Improvements in or relating to antibodies active against human hemoglobin Asub(1C)

    Javid, J.; Cerami, A.; Koenig, R.J.; Pettis, P.K.

    1980-01-01

    A method is described for preparing an antibody against human hemoglobin Asub(1c) which is substantially free of cross-reactivity against the human hemoglobins A 0 , Asub(1a) and Asub(1b). The antibodies are collected from cats, goats or sheep following injections of purified hemoglobin Asub(1c) antigen since these animals do not naturally produce hemoglobin Asub(1c). A radioimmunoassay method is also described whereby these antibodies are used to determine the quantity of hemoglobin Asub(1c) in blood samples. This is a useful technique in the diagnosis of diabetes mellitus. (U.K.)

  18. Concurrent measurement of cellular turbidity and hemoglobin to evaluate the antioxidant activity of plants.

    Bellik, Yuva; Iguer-Ouada, Mokrane

    2016-01-01

    In past decades, a multitude of analytical methods for measuring antioxidant activity of plant extracts has been developed. However, when using methods to determine hemoglobin released from human erythrocytes treated with ginger extracts, we found hemoglobin concentrations were significantly higher than in untreated control samples. This suggests in the presence of antioxidants that measuring hemoglobin alone is not sufficient to determine hemolysis. We show concurrent measurement of erythrocyte concentration and hemoglobin is essential in such assays, and describe a new protocol based on simultaneous measurement of cellular turbidity and hemoglobin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Effect of ethanol of the radiation sensitivity of human hemoglobin

    Szweda-Lewandowska, Z.; Puchala, M.

    1981-01-01

    Radiation sensitivity of oxy-, deoxy-, and methemoglobin (HbOs, Hbbj, and MetHb) in water solutions containing 0.2 M ethanol and in ethanol-free solutions was compared. Radiation sensitivity was estimated on the basis of changes in absorbance at the Soret band (a = 430 nm for deoxyhemoglobin), changes in the absorbance ration Avqv/Avwt determined after conversion of irradiated preparations to methemoglobin, and changes in the value of parameters describing the reaction of hemoglobin oxygenation. The protection coefficient p of hemoglobin by ethanol (ratio of a change in the absence of ethanol to that in its presence) calculated from changes in absorbance at the Soret band equaled about 1.5 at a 4-Mrad dose in all bases except MetHb irradiated in air for which p was much higher (about 3.2). The protection coefficient p' calculated from Dtx values for changes in Avchemically bondv/Avwt equaled 2.2 for HbOs, and 2.8 for MetHb for preparations irradiated in air; p' = 1.7 for Hbbj and 1.8 for MetHb for preparations irradiated under argon. On the basis of these results, the role of /sup ./OH radicals and oxygen in the radiation damage of hemoglobin is discussed

  20. Hydrogen-tritium exchange survey of allosteric effects in hemoglobin

    Englander, J.J.; Englander, S.W.

    1987-01-01

    The oxy and deoxy forms of hemoglobin display major differences in H-exchange behavior. Hydrogen-tritium exchange experiments on hemoglobin were performed in the low-resolution mode to observe the dependence of these differences on pH (Bohr effect), organic phosphates, and salt. Unlike a prior report, increasing pH was found to decrease the oxy-deoxy difference monotonically, in general accordance with the alkaline Bohr effect. A prior report that the H-exchange difference between oxy- and deoxyhemoglobin vanishes at pH 9, and thus appears to reflect the Bohr effect alone, was found to be due to the borate buffer used, which at high pH tends to abolish the oxy-deoxy difference in a limited region of the H-exchange curve. Effects on hemoglobin H exchange due to organic phosphates parallel the differential binding of these agents (inositol hexaphosphate more than diphosphoglycerate, deoxy more than oxy, at low pH more than at high pH). Added salt slows H exchange of deoxyhemoglobin and has no effect on the oxy form. These results display the sensitivity of simple H-exchange measurements for finding and characterizing effects on structure and dynamics that may occur anywhere in the protein and help to define conditions for higher resolution approaches that can localize the changes observed

  1. Pitfalls in the biological diagnosis of common hemoglobin disorders.

    Wajcman, Henri; Moradkhani, Kamran

    2015-01-01

    In West-European countries, hemoglobin disorders are no more rare diseases. Programs for diagnosis of heterozygous carriers have been established to prevent cases with major sickle cell disease or thalassemias. These studies have been done essentially by high performance liquid chromatography on cation-exchange columns and electrophoresis (mostly capillary electrophoresis). They have been done through systematic population studies or premarital diagnosis. We describe in this work the frequent or rare pitfalls encountered, which led to false negative or positive diagnosis both in the field of sickle cell disease and thalassemias. In the absence of a well identified hemoglobin disorder in the proband's family, it is a rule that the use of a single test is insufficient to identify formally HbS. The presence of HbS could also be masked by another hemoglobin abnormality. The sole measurement of HbA2 level is insufficient to characterize a thalassemic trait: this level needs always to be interpreted considering RBC parameters and iron metabolic status. In difficult cases, the definitive answer may require a family study and/or a molecular genetic characterization.

  2. Carbon monoxide reduces near-infrared spectroscopy determined 'total' hemoglobin

    Niemann, Mads J; Sørensen, Henrik; Siebenmann, Christoph

    2017-01-01

    with CO (1.5 mL kg-1) was added to the circuit. Two NIRS systems (NIRO-200NX and INVOS-5100) assessed ScO2 as the ratio of oxygenated to deoxygenated hemoglobin, while venous blood samples were analyzed for carboxyhemoglobin (COHb). After CO/O2 rebreathing COHb increased to 8.7% (IQR; 7.9-9.4; p = .004...... to normoxia (68.9 ± 6.9%; p hemoglobin decreased (by 19.7 μM (median; IQR 2.8-34.8; p = .016) and 37.3 μM (30.8-46.6; p = .004), respectively) during inhalation of CO/O2 compared...... to inhalation of O2. Therefore, NIRO-200NX determined 'total' hemoglobin (sum of O2Hb and HHb) decreased (by 62.1 μM; 44.5-78.2; p = .001). In conclusion, exposure to CO did not increase MCAVmean, and neither NIRO-200NX nor INVOS-5100 detected a change in ScO2 when CO was added to inhalation of oxygen...

  3. Characterization of trypsin-derived peptides acrylamide-adducted hemoglobin

    Springer, D.L.; Goheen, S.C.; Edmonds, C.G.; McCulloch, M.; Sylvester, D.M.; Sander, C.; Bull, R.J.

    1991-01-01

    Even though there are a number of sources for human exposure to acrylamide, reliable biomarkers of exposure are not available. In an effort to develop such a biomarker, the authors are characterizing peptides derived from trypsin digests of acrylamide-adducted hemoglobin. For this, radiolabeled acrylamide was incubated with this, radiolabeled acrylamide was incubated with purified human hemoglobin (Ao) and decomposition products removed by dialysis. When the adducted hemoglobin was separated by reverse-phase HPLC, radioactivity eluted with the α and β subunits, suggesting covalent binding. Digestion of individual subunits with trypsin followed by reverse phase HPLC, indicated that most of the radioactivity associated with the α subunit co-eluted with a single peptide. Similar results were observed for the β subunit except that significant amounts of radioactivity eluted with the solvent front, suggesting that radioactivity was released by trypsin digestion. Currently, these preparation are under further characterization by electrospray ionization mass spectrometry. This approach will aid in the identification of the adducted will aid in the identification of the adducted peptide and subsequent preparation of an acrylamide-specific antibody

  4. Structural and functional properties of hemoglobins from unicellular organisms as revealed by resonance Raman spectroscopy.

    Egawa, Tsuyoshi; Yeh, Syun-Ru

    2005-01-01

    Hemoglobins have been discovered in organisms from virtually all kingdoms. Their presence in unicellular organisms suggests that the gene for hemoglobin is very ancient and that the hemoglobins must have functions other than oxygen transport, in view of the fact that O2 delivery is a diffusion-controlled process in these organisms. Based on sequence alignment, three groups of hemoglobins have been characterized in unicellular organisms. The group-one hemoglobins, termed truncated hemoglobins, consist of proteins with 110-140 amino acid residues and a novel two-over-two alpha-helical sandwich motif. The group-two hemoglobins, termed flavohemoglobins, consist of a hemoglobin domain, with a classical three-over-three alpha-helical sandwich motif, and a flavin-containing reductase domain that is covalently attached to it. The group-three hemoglobins consist of myoglobin-like proteins that have high sequence homology and structural similarity to the hemoglobin domain of flavohemoglobins. In this review, recent resonance Raman studies of each group of these proteins are presented. Their implications are discussed in the context of the structural and functional properties of these novel hemoglobins.

  5. Electrocatalysis of hemoglobin in ionic liquid BMIMPF6 and CuS nanosphere composite films

    Wei Sun

    2011-12-01

    Full Text Available Ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF6 was mixed homogeneously with nanometer-sized semiconductor CuS sphere to form a new nanocomposite material, which was further used for the immobilization of hemoglobin (Hb on the surface of carbon paste electrode (CPE. Direct electrochemistry of Hb in BMIMPF6-CuS composite film was carefully investigated with a pair of quasi-reversible redox peaks appeared and the formal potential (E0' was got as -135 mV (vs. SCE in pH 7.0 phosphate buffer solution, which was due to the enhanced direct electron transfer rate of Hb in the biocompatible matrix. The BMIMPF6-CuS-Hb/CPE showed excellent electrocatalytic activity to the reduction of hydrogen peroxide with the kinetic parameters for the electrocatalytic reaction evaluated. The results indicated that the BMIMPF6-CuS nanocomposite could be used for the preparation of electrochemical biosensor.

  6. Novel Luminescent Probe Based on a Terbium(III) Complex for Hemoglobin Determination

    Yegorova, A. V.; Leonenko, I. I.; Aleksandrova, D. I.; Scrypynets, Yu. V.; Antonovich, V. P.; Ukrainets, I. V.

    2014-09-01

    We have studied the spectral luminescent properties of Tb(III) and Eu(III) complexes with a number of novel derivatives of oxoquinoline-3-carboxylic acid amides (L1-L5 ). We have observed quenching of the luminescence of 1:1 Tb(III)-L1-5 complexes by hemoglobin (Hb), which is explained by resonance energy transfer of electronic excitation from the donor (Tb(III)-L1-5 ) to the acceptor (Hb). Using the novel luminescent probe Tb(III)-L1, we have developed a method for determining Hb in human blood. The calibration Stern-Volmer plot is linear in the Hb concentration range 0.6-36.0 μg/mL, detection limit 0.2 μg/mL (3·10-9 mol/L).

  7. Amperometric biosensor based on direct electrochemistry of hemoglobin in poly-allylamine (PAA) film

    Kafi, A.K.M.; Lee, Dong-Yun; Park, Sang-Hyun; Kwon, Young-Soo

    2007-01-01

    Hemoglobin (Hb) was immobilized in poly-allylamine (PAA) film onto the gold electrode by layer by layer (LBL) method. The modified electrode exhibited a pair of well-defined peaks during cyclic voltammetry, which was attributed from the direct electron transfer of heme proteins. The immobilized Hb showed an excellent electrocatalytical response to the reduction of hydrogen peroxide. The sensor exhibited a fast response and high sensitivity. Through the use of optimized conditions, the linear range for H 2 O 2 detection was from 2.5 x 10 -6 M to 5 x 10 -4 M with detection limit of 0.2 μM. The proposed biosensor showed long-lasting stability and excellent reproducibility

  8. Application of N-doped graphene modified carbon ionic liquid electrode for direct electrochemistry of hemoglobin.

    Sun, Wei; Dong, Lifeng; Deng, Ying; Yu, Jianhua; Wang, Wencheng; Zhu, Qianqian

    2014-06-01

    Nitrogen-doped graphene (NG) was synthesized and used for the investigation on direct electrochemistry of hemoglobin (Hb) with a carbon ionic liquid electrode as the substrate electrode. Due to specific characteristics of NG such as excellent electrocatalytic property and large surface area, direct electron transfer of Hb was realized with enhanced electrochemical responses appearing. Electrochemical behaviors of Hb on the NG modified electrode were carefully investigated with the electrochemical parameters calculated. The Hb modified electrode exhibited excellent electrocatalytic reduction activity toward different substrates, such as trichloroacetic acid and H2O2, with wider dynamic range and lower detection limit. These findings show that NG can be used for the preparation of chemically modified electrodes with improved performance and has potential applications in electrochemical sensing. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Top-Down Proteomics and Direct Surface Sampling of Neonatal Dried Blood Spots: Diagnosis of Unknown Hemoglobin Variants

    Edwards, Rebecca L.; Griffiths, Paul; Bunch, Josephine; Cooper, Helen J.

    2012-11-01

    We have previously shown that liquid microjunction surface sampling of dried blood spots coupled with high resolution top-down mass spectrometry may be used for screening of common hemoglobin variants HbS, HbC, and HbD. In order to test the robustness of the approach, we have applied the approach to unknown hemoglobin variants. Six neonatal dried blood spot samples that had been identified as variants, but which could not be diagnosed by current screening methods, were analyzed by direct surface sampling top-down mass spectrometry. Both collision-induced dissociation and electron transfer dissociation mass spectrometry were employed. Four of the samples were identified as β-chain variants: two were heterozygous Hb D-Iran, one was heterozygous Hb Headington, and one was heterozygous Hb J-Baltimore. The fifth sample was identified as the α-chain variant heterozygous Hb Phnom Penh. Analysis of the sixth sample suggested that it did not in fact contain a variant. Adoption of the approach in the clinic would require speed in both data collection and interpretation. To address that issue, we have compared manual data analysis with freely available data analysis software (ProsightPTM). The results demonstrate the power of top-down proteomics for hemoglobin variant analysis in newborn samples.

  10. Online Resources

    Home; Journals; Journal of Genetics; Online Resources. Journal of Genetics. Online Resources. Volume 97. 2018 | Online resources. Volume 96. 2017 | Online resources. Volume 95. 2016 | Online resources. Volume 94. 2015 | Online resources. Volume 93. 2014 | Online resources. Volume 92. 2013 | Online resources ...

  11. Fasting serum glucose and glycosylated hemoglobin level in obesity.

    Das, R K; Nessa, A; Hossain, M A; Siddiqui, N I; Hussain, M A

    2014-04-01

    Obesity is a condition in which the body fat stores are increased to an extent which impairs health and leads to serious health consequences. The amount of body fat is difficult to measure directly, and is usually determined from an indirect measure - the body mass index (BMI). Increased BMI in obese persons is directly associated with an increase in metabolic disease, such as type 2 diabetes mellitus. This Analytical cross sectional study was undertaken to assess the relation between obesity and glycemic control of body by measuring fasting serum glucose and glycosylated hemoglobin. This study was carried out in the Department of Physiology, Mymensingh Medical College, Mymensingh from 1st July 2011 to 30th June 2012 on 120 equally divided male and female persons within the age range of 25 to 55 years. Age more than 55 years and less than 25 years and diagnosed case of Hypothyroidism, Cushing's syndrome, polycystic ovary, Antipsychotic drug user and regular steroid users were excluded. Non probability purposive type of sampling technique was used for selecting the study subjects. Measurement of body mass index was done as per procedure. Fasting serum glucose was estimated by glucose oxidase method and Glycosylated hemoglobin by Boronate Affinity method. Statistical analysis was done by SPSS (version 17.0). Data were expressed as Mean±SE and statistical significance of difference among the groups were calculated by unpaired student's 't' test and Pearson's correlation coefficient tests were done as applicable. The Mean±SE of fasting serum glucose was significant at 1% level (P value obese group of BMI. There was no significant difference of glycosylated hemoglobin level between control and study groups. But there was positive correlation within each group. Fasting serum glucose also showed a bit stronger positive correlation with BMI. Both obese male and female persons showed higher levels of fasting serum glucose and glycosylated hemoglobin. The observed positive

  12. Aqueous synthesis and characterization of bovine hemoglobin-conjugated cadmium sulfide nanocrystals

    Yang, Guangrui [Institute of Environmental and Municipal Engineering, North China University of Water Conservancy and Electric Power, Zhengzhou 450011 (China); Qin, Dezhi, E-mail: dezhiqin@163.com [College of Chemistry and Chemical Engineering, Pingdingshan University, Pingdingshan 467000 (China); Du, Xian; Zhang, Li; Zhao, Ganqing; Zhang, Qiuxia; Wu, Jiulin [College of Chemistry and Chemical Engineering, Pingdingshan University, Pingdingshan 467000 (China)

    2014-08-01

    Highlights: • CdS nanocrystals were synthesized by biomimetic method in bovine hemoglobin (BHb) solution. • The study of the interaction between Cd{sup 2+}/CdS and BHb. • The optical properties of BHb-conjugated CdS nanocrystals. • The synthesis process of BHb-conjugated CdS nanocrystals is facile, effective and environment friendly. • The change of secondary structure of BHb after binding to CdS nanocrystals. - Abstract: Cadmium sulfide (CdS) nanocrystals with average diameter about 5.5 nm were synthesized in aqueous solution of bovine hemoglobin (BHb) via simple biomimetic method. Powder X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM) and selected area electron diffraction (SAED) characterizations were used to determine the structure and morphology of CdS nanocrystals. It was revealed that amount of BHb, chelating of Cd{sup 2+} to BHb and reaction temperature were key factors in controlling shape and dispersion of CdS nanocrystals. The binding sites of BHb to CdS nanocrystals and the change of secondary structure of protein have been identified by Fourier transform infrared (FT-IR) and circular dichroism (CD) spectroscopy. It was found that conjugating of BHb with Cd{sup 2+} and CdS could protect nanocrystals from agglomerating. Moreover, the thermostability of BHb enhanced after conjugating with CdS nanocrystals. The interaction mechanism of BHb with Cd{sup 2+}/CdS was also proposed. The quantum-confined effect of CdS nanocrystals was confirmed by ultraviolet–visible (UV–vis) spectrum. The nanocrystals exhibited a well-defined photoluminescence (PL) emission feature at about 510 nm with narrow full width at half maximum (FWHM)

  13. Modeling hemoglobin and hemoglobin:haptoglobin complex clearance in a non-rodent species–pharmacokinetic and therapeutic implications

    Boretti, Felicitas S.; Baek, Jin Hyen; Palmer, Andre F.; Schaer, Dominik J.; Buehler, Paul W.

    2014-01-01

    Background: Haptoglobin (Hp) prevents hemoglobin (Hb) extravasation and attenuates Hb induced tissue oxidation and vasoconstriction. Small animal models such as mouse, rat and guinea pig appear to demonstrate proof-of-concept for Hb neutralization by Hp in diverse pre-clinical conditions. However, these species differ significantly from humans in the clearance of Hb:Hp and demonstrate long persistence of circulating Hb:Hp complexes. Objective: The focus of this study is to understand Hb:Hp...

  14. Interactive Electronic Decision Trees for the Integrated Primary Care Management of Febrile Children in Low Resource Settings - Review of existing tools.

    Keitel, Kristina; D'Acremont, Valérie

    2018-04-20

    The lack of effective, integrated diagnostic tools pose a major challenge to the primary care management of febrile childhood illnesses. These limitations are especially evident in low-resource settings and are often inappropriately compensated by antimicrobial over-prescription. Interactive electronic decision trees (IEDTs) have the potential to close these gaps: guiding antibiotic use and better identifying serious disease. This narrative review summarizes existing IEDTs, to provide an overview of their degree of validation, as well as to identify gaps in current knowledge and prospects for future innovation. Structured literature review in PubMed and Embase complemented by google search and contact with developers. Six integrated IEDTs were identified: three (eIMCI, REC, and Bangladesh digital IMCI) based on Integrated Management of Childhood Illnesses (IMCI); four (SL eCCM, MEDSINC, e-iCCM, and D-Tree eCCM) on Integrated Community Case Management (iCCM); two (ALMANACH, MSFeCARE) with a modified IMCI content; and one (ePOCT) that integrates novel content with biomarker testing. The types of publications and evaluation studies varied greatly: the content and evidence-base was published for two (ALMANACH and ePOCT), ALMANACH and ePOCT were validated in efficacy studies. Other types of evaluations, such as compliance, acceptability were available for D-Tree eCCM, eIMCI, ALMANACH. Several evaluations are still ongoing. Future prospects include conducting effectiveness and impact studies using data gathered through larger studies to adapt the medical content to local epidemiology, improving the software and sensors, and Assessing factors that influence compliance and scale-up. IEDTs are valuable tools that have the potential to improve management of febrile children in primary care and increase the rational use of diagnostics and antimicrobials. Next steps in the evidence pathway should be larger effectiveness and impact studies (including cost analysis) and

  15. Hydroxyurea-Increased Fetal Hemoglobin Is Associated with Less Organ Damage and Longer Survival in Adults with Sickle Cell Anemia.

    Fitzhugh, Courtney D; Hsieh, Matthew M; Allen, Darlene; Coles, Wynona A; Seamon, Cassie; Ring, Michael; Zhao, Xiongce; Minniti, Caterina P; Rodgers, Griffin P; Schechter, Alan N; Tisdale, John F; Taylor, James G

    2015-01-01

    Adults with sickle cell anemia (HbSS) are inconsistently treated with hydroxyurea. We retrospectively evaluated the effects of elevating fetal hemoglobin with hydroxyurea on organ damage and survival in patients enrolled in our screening study between 2001 and 2010. An electronic medical record facilitated development of a database for comparison of study parameters based on hydroxyurea exposure and dose. This study is registered with ClinicalTrials.gov, number NCT00011648. Three hundred eighty-three adults with homozygous sickle cell disease were analyzed with 59 deaths during study follow-up. Cox regression analysis revealed deceased subjects had more hepatic dysfunction (elevated alkaline phosphatase, Hazard Ratio = 1.005, 95% CI 1.003-1.006, phydroxyurea, although only 66% of those received a dose within the recommended therapeutic range. Hydroxyurea use was associated with improved survival (Hazard Ratio = 0.58, 95% CI 0.34-0.97, p = 0.040). This effect was most pronounced in those taking the recommended dose of 15-35 mg/kg/day (Hazard Ratio 0.36, 95% CI 0.17-0.73, p = 0.0050). Hydroxyurea use was not associated with changes in organ function over time. Further, subjects with higher fetal hemoglobin responses to hydroxyurea were more likely to survive (p = 0.0004). While alkaline phosphatase was lowest in patients with the best fetal hemoglobin response (95.4 versus 123.6, p = 0.0065 and 96.1 versus 113.6U/L, p = 0.041 at first and last visits, respectively), other markers of organ damage were not consistently improved over time in patients with the highest fetal hemoglobin levels. Our data suggest that adults should be treated with the maximum tolerated hydroxyurea dose, ideally before organ damage occurs. Prospective studies are indicated to validate these findings.

  16. Hemoglobin redux: combining neutron and X-ray diffraction with mass spectrometry to analyse the quaternary state of oxidized hemoglobins

    Mueser, Timothy C., E-mail: timothy.mueser@utoledo.edu; Griffith, Wendell P. [Department of Chemistry, University of Toledo, Toledo, OH 43606 (United States); Kovalevsky, Andrey Y. [Bioscience Division, MS M888, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Guo, Jingshu; Seaver, Sean [Department of Chemistry, University of Toledo, Toledo, OH 43606 (United States); Langan, Paul [Department of Chemistry, University of Toledo, Toledo, OH 43606 (United States); Bioscience Division, MS M888, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Hanson, B. Leif [Department of Chemistry, University of Toledo, Toledo, OH 43606 (United States)

    2010-11-01

    X-ray and neutron diffraction studies of cyanomethemoglobin are being used to evaluate the structural waters within the dimer–dimer interface involved in quaternary-state transitions. Improvements in neutron diffraction instrumentation are affording the opportunity to re-examine the structures of vertebrate hemoglobins and to interrogate proton and solvent position changes between the different quaternary states of the protein. For hemoglobins of unknown primary sequence, structural studies of cyanomethemoglobin (CNmetHb) are being used to help to resolve sequence ambiguity in the mass spectra. These studies have also provided additional structural evidence for the involvement of oxidized hemoglobin in the process of erythrocyte senescence. X-ray crystal studies of Tibetan snow leopard CNmetHb have shown that this protein crystallizes in the B state, a structure with a more open dyad, which possibly has relevance to RBC band 3 protein binding and erythrocyte senescence. R-state equine CNmetHb crystal studies elaborate the solvent differences in the switch and hinge region compared with a human deoxyhemoglobin T-state neutron structure. Lastly, comparison of histidine protonation between the T and R state should enumerate the Bohr-effect protons.

  17. Library resources on the Internet

    Buchanan, Nancy L.

    1995-07-01

    Library resources are prevalent on the Internet. Library catalogs, electronic books, electronic periodicals, periodical indexes, reference sources, and U.S. Government documents are available by telnet, Gopher, World Wide Web, and FTP. Comparatively few copyrighted library resources are available freely on the Internet. Internet implementations of library resources can add useful features, such as full-text searching. There are discussion lists, Gophers, and World Wide Web pages to help users keep up with new resources and changes to existing ones. The future will bring more library resources, more types of library resources, and more integrated implementations of such resources to the Internet.

  18. Current hemoglobin levels are more predictive of disease progression than hemoglobin measured at baseline in patients receiving antiretroviral treatment for HIV type 1 infection

    Kowalska, Justyna D; Mocroft, Amanda; Blaxhult, Anders

    2007-01-01

    The role of hemoglobin levels as an independent prognostic marker of progression to AIDS and/or death in HIV-infected patients starting combination antiretroviral therapy (cART) was investigated. A total of 2,579 patients from the EuroSIDA cohort with hemoglobin, CD4 cell count, and HIV RNA viral...

  19. Glycated hemoglobin biosensing integration formed on Au nanoparticle-dotted tubular TiO{sub 2} nanoarray

    Jain, Utkarsh [Amity Institute of Nanotechnology, Amity University, Noida, 201303, Uttar Pradesh (India); Singh, Anamika [Department of Biotechnology, UIET, Kurukshetra University, Kurukshetra, 136 119, Haryana (India); Kuchhal, Naresh Kumar [Clinical Biochemistry Department, Bio-Diagnostics, Rohini, Delhi, 110085 (India); Chauhan, Nidhi, E-mail: nidhichauhan2007@rediffmail.com [Amity Institute of Nanotechnology, Amity University, Noida, 201303, Uttar Pradesh (India)

    2016-11-16

    Excessive glucose present in the blood of diabetic patients binds with the hemoglobin of red blood cells resulting in the formation of glycated hemoglobin (HbA{sub 1c}). Measurement of HbA{sub 1c} levels may help in identifying the efficacy of the ongoing treatment and hence provide a better control over the disease. In the present study, we have synthesized a sensitive and stable scaffold, which consists of Au nanoparticles (GNPs)-dotted tubular TiO{sub 2}, for the construction of an electrochemical HbA{sub 1c} biosensor. 12-phosphotungstic acid has been used as a reducer after depositing well-dispersed GNPs on TiO{sub 2} nanotubes (TiO{sub 2} NTs) and an electron mediator by accelerating the electron transfer between the conductor and protein. The fabricated electrode was characterized using scanning electron microscopy (SEM), cyclic voltammetry (CV), Fourier transform infrared spectroscopy (FTIR) and electrochemical impedance spectroscopic analysis (EIS). Biosensor exhibited low detection limit (0.5 μM), fast response time (3 s) and wide linearity (from 0.5 to 2000 μM). The working electrode was used 100 times over 4 months, when stored at 4 °C. The HbA1c biosensor was then effectively used to measure the % of HbA{sub 1c} in the blood of apparently healthy persons and diabetic patients. - Highlights: • Fabrication of a highly sensitive and stable sensing interface consisting of gold nanoparticles (GNPs) and tubular TiO2. • Biosensor exhibited low detection limit (0.5 μM). • The half life of electrode was 4 months. • Biosensor was suitable for detection of glycated hemoglobin in whole blood.

  20. Clinical, hematological and genetic data of a cohort of children with hemoglobin SD

    Paulo do Val Rezende

    Full Text Available ABSTRACT INTRODUCTION: The hemoglobin FSD is very uncommon in newborn screening programs for sickle cell disease. In the program of Minas Gerais, Brazil, the clinical course of children with hemoglobin SD was observed to be heterogeneous. The objective of this study was to estimate the incidence (1999-2012 and to describe the natural history of a cohort of newborns with hemoglobin SD. METHODS: Isoelectric focusing was the primary method used in newborn screening. Polymerase chain reaction-restriction fragment length polymorphism and gene sequencing were used to identify mutant alleles and for haplotyping. Gap-polymerase chain reaction was used to detect alpha-thalassemia. RESULTS: Eleven cases of hemoglobin S/D-Punjab and eight of Hb S-Korle Bu were detected. Other variants with hemoglobin D mobility were not identified. All hemoglobin D-Punjab and hemoglobin Korle Bu alleles were associated with haplotype I. Among the children with hemoglobin S/D-Punjab, there were four with the ßS CAR haplotype, six with the Benin haplotype, and one atypical. Results of laboratory tests for hemoglobin S/D-Punjab and hemoglobin S-Korle Bu were: hemoglobin 8.0 and 12.3 g/dL (p-value <0.001, leukocyte count 13.9 × 109/L and 10.5 × 109/L (p-value = 0.003, reticulocytes 7.5% and 1.0% (p-value <0.001, hemoglobin F concentration 16.1% and 6.9% (p-value = 0.001 and oxygen saturation 91.9% and 97% (p-value = 0.002, respectively. Only hemoglobin S/D-Punjab children had acute pain crises and needed blood transfusions or hydroxyurea. Those with the Benin ßS haplotype had higher total hemoglobin and hemoglobin F concentrations compared to the CAR haplotype. Transcranial Doppler was normal in all children. CONCLUSION: The clinical course and blood cell counts of children with hemoglobin S/D-Punjab were very similar to those of hemoglobin SS children. In contrast, children with hemoglobin S-Korle Bu had clinical course and blood cell counts like children with the sickle

  1. Structure and stability of human hemoglobin microparticles prepared with a double emulsion technique.

    Cedrati, N; Bonneaux, F; Labrude, P; Maincent, P

    1997-09-01

    Hemoglobin solutions can be used as blood substitutes but they present some disadvantages often due to their rapid removal from the bloodstream after injection. A possible way of overcoming this problem is to trap hemoglobin inside particles. This study deals with the preparation, structure and stability of poly(lactic acid) and ethylcellulose microparticles containing human hemoglobin obtained with a double emulsion technique. We investigated the manufacturing process of these particles in order to increase the encapsulation ratio of hemoglobin. For this purpose, some parameters involved in the procedure were optimized, such as hemoglobin concentration and duration of stirring: hemoglobin loading increases with its concentration in the preparation and well-defined stirring time avoids a leakage of hemoglobin. Hemoglobin concentration, surfactant concentration i.e. poly(vinylic alcohol), amounts of polymer and solvent (methylene chloride), duration and speed of stirring. The microparticles were prepared with satisfactory yields (60 to 73%). They were spherical and their mean size was lower than 200 microns. The functional properties of entrapped hemoglobin were studied. The encapsulation did not alter hemoglobin and the oxygen affinity of the hemoglobin remained unmodified (P50 about 13.9 mm Hg in a Bis-Tris buffer pH 7.4 at 37 degrees C). Moreover, only low levels of methemoglobin could be detected (less than 3%). Besides, about 90% of encapsulated hemoglobin could be released from microparticles, with a speed related to the internal structure of the particles. The prepared microparticles were stored during one month at +4 degrees C. No degradation of the particle structure occurred and the functional properties of hemoglobin were preserved. These particles could provide a potential source of oxygen in the field of biotechnologies but any application for a transfusional purpose would first require a drastic reduction in particle size.

  2. Herpes - resources

    Genital herpes - resources; Resources - genital herpes ... following organizations are good resources for information on genital herpes : March of Dimes -- www.marchofdimes.org/complications/sexually- ...

  3. Effects of hydroxyurea treatment for patients with hemoglobin SC disease.

    Luchtman-Jones, Lori; Pressel, Sara; Hilliard, Lee; Brown, R Clark; Smith, Mary G; Thompson, Alexis A; Lee, Margaret T; Rothman, Jennifer; Rogers, Zora R; Owen, William; Imran, Hamayun; Thornburg, Courtney; Kwiatkowski, Janet L; Aygun, Banu; Nelson, Stephen; Roberts, Carla; Gauger, Cynthia; Piccone, Connie; Kalfa, Theodosia; Alvarez, Ofelia; Hassell, Kathryn; Davis, Barry R; Ware, Russell E

    2016-02-01

    Although hemoglobin SC (HbSC) disease is usually considered less severe than sickle cell anemia (SCA), which includes HbSS and HbS/β(0) -thalassemia genotypes, many patients with HbSC experience severe disease complications, including vaso-occlusive pain, acute chest syndrome, avascular necrosis, retinopathy, and poor quality of life. Fully 20 years after the clinical and laboratory efficacy of hydroxyurea was proven in adult SCA patients, the safety and utility of hydroxyurea treatment for HbSC patients remain unclear. Recent NHLBI evidence-based guidelines highlight this as a critical knowledge gap, noting HbSC accounts for ∼30% of sickle cell patients within the United States. To date, only 5 publications have reported short-term, incomplete, or conflicting laboratory and clinical outcomes of hydroxyurea treatment in a total of 71 adults and children with HbSC. We now report on a cohort of 133 adult and pediatric HbSC patients who received hydroxyurea, typically for recurrent vaso-occlusive pain. Hydroxyurea treatment was associated with a stable hemoglobin concentration; increased fetal hemoglobin (HbF) and mean corpuscular volume (MCV); and reduced white blood cell count (WBC), absolute neutrophil count (ANC), and absolute reticulocyte count (ARC). Reversible cytopenias occurred in 22% of patients, primarily neutropenia and thrombocytopenia. Painful events were reduced with hydroxyurea, more in patients >15 years old. These multicenter data support the safety and potentially salutary effects of hydroxyurea treatment for HbSC disease; however, a multicenter, placebo-controlled, Phase 3 clinical trial is needed to determine if hydroxyurea therapy has efficacy for patients with HbSC disease. © 2015 Wiley Periodicals, Inc.

  4. Spectroscopic markers of the TR quaternary transition in human hemoglobin.

    Schirò, Giorgio; Cammarata, Marco; Levantino, Matteo; Cupane, Antonio

    2005-04-01

    In this work, we use a sol-gel protocol to trap and compare the R and T quaternary states of both the deoxygenated (deoxyHb) and carbonmonoxide (HbCO) derivatives of human hemoglobin. The near infrared optical absorption band III and the infrared CO stretching band are used to detect the effect of quaternary structure on the spectral properties of deoxyHb and HbCO; comparison with myoglobin allows for an assessment of tertiary and quaternary contributions to the measured band shifts. The RT transition is shown to cause a blue shift of the band III by approximately 35 cm(-1) for deoxyHb and a red shift of the CO stretching band by only approximately 0.3 cm(-1) for HbCO. This clearly shows that quaternary structure changes are transmitted to the heme pocket and that effects on deoxyHb are much larger than on HbCO, at least as far as the band energies are concerned. Experiments performed in the ample temperature interval of 300-10K show that the above quaternary structure effects are "static" and do not influence the dynamic properties of the heme pocket, at least as probed by the temperature dependence of band III and of the CO stretching band. The availability of quaternary structure sensitive spectroscopic markers and the quantitative measurement of the quaternary structure contribution to band shifts will be of considerable help in the analysis of flash-photolysis experiments on hemoglobin. Moreover, it will enable one to characterize the dynamic properties of functionally relevant hemoglobin intermediates and to study the kinetics of both the T-->R and R-->T quaternary transitions through time-resolved spectroscopy.

  5. Techniques used for the screening of hemoglobin levels in blood donors: current insights and future directions

    Chaudhary R

    2017-07-01

    Full Text Available Rajendra Chaudhary,1 Anju Dubey,2 Atul Sonker3 1Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, 2Department of Transfusion Medicine, T.S. Misra Medical College and Hospital, 3Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India Abstract: Blood donor hemoglobin (Hb estimation is an important donation test that is performed prior to blood donation. It serves the dual purpose of protecting the donors’ health against anemia and ensuring good quality of blood components, which has an implication on recipients’ health. Diverse cutoff criteria have been defined world over depending on population characteristics; however, no testing methodology and sample requirement have been specified for Hb screening. Besides the technique, there are several physiological and methodological factors that affect accuracy and reliability of Hb estimation. These include the anatomical source of blood sample, posture of the donor, timing of sample and several other biological factors. Qualitative copper sulfate gravimetric method has been the archaic time-tested method that is still used in resource-constrained settings. Portable hemoglobinometers are modern quantitative devices that have been further modified to reagent-free cuvettes. Furthermore, noninvasive spectrophotometry was introduced, mitigating pain to blood donor and eliminating risk of infection. Notwithstanding a tremendous evolution in terms of ease of operation, accuracy, mobility, rapidity and cost, a component of inherent variability persists, which may partly be attributed to pre-analytical variables. Hence, blood centers should pay due attention to validation of test methodology, competency of operating staff and regular proficiency testing of the outputs. In this article, we have reviewed various regulatory guidelines, described the variables that affect the measurements and compared the validated

  6. Synthesis of iron nanoparticles from hemoglobin and myoglobin

    Sayyad, Arshad S; Ajayan, Pulickel M; Balakrishnan, Kaushik; Ci, Lijie; Kabbani, Ahmad T; Vajtai, Robert

    2012-01-01

    Stable iron nanoparticles have been synthesized from naturally occurring and abundant Fe-containing bio-precursors, namely hemoglobin and myoglobin. The formation of stable iron nanoparticles was achieved through a one-pot, single-phase chemical reduction approach. The reduction of iron ions present in the bio-precursors was carried out at room temperature and avoids the use of harsh chemical reagents. The size distribution of the product falls into the narrow 2–5 nm range and the particles were found to be crystalline. This method can be a valuable synthetic approach for producing bio-conjugated nanoparticle systems for biological applications. (paper)

  7. The Correlation of Hemoglobin A1c to Blood Glucose

    Sikaris, Ken

    2009-01-01

    The understanding that hemoglobin A1c (HbA1c) represents the average blood glucose level of patients over the previous 120 days underlies the current management of diabetes. Even in making such a statement, we speak of “average blood glucose” as though “blood glucose” were itself a simple idea. When we consider all the blood glucose forms—arterial versus venous versus capillary, whole blood versus serum versus fluoride-preserved plasma, fasting versus nonfasting—we can start to see that this ...

  8. Optoacoustic monitoring of blood hemoglobin concentration: a pilot clinical study

    Petrova, Irina Y.; Esenaliev, Rinat O.; Petrov, Yuriy Y.; Brecht, Hans-Peter F.; Svensen, Christer H.; Olsson, Joel; Deyo, Donald J.; Prough, Donald S.

    2005-07-01

    The optoacoustic technique is noninvasive, has high spatial resolution, and potentially can be used to measure the total hemoglobin concentration ([THb]) continuously and accurately. We performed in vitro measurements in blood and in vivo tests in healthy volunteers. Our clinical protocol included rapid infusion of intravenous saline to simulate rapid change in the [THb] during fluid therapy or surgery. Optoacoustic measurements were made from the wrist area overlying the radial artery for more than 1 h. The amplitude of the optoacoustic signal generated in the radial artery closely followed the [THb] measured directly in concurrently collected blood samples.

  9. Moessbauer studies of hemoglobin in high altitude polycythemia

    Zhang Xiufang; Shen Linming; Chen Songsen; Ao Zhaohui; Liu Yuanyuan; Gao Naifei; Zheng Yuanming; Shong Liangquan

    1990-01-01

    The Moessbauer spectra have been measured in erythrocytes from normal adults and the patients with high altitude polycythemia (HAPC). The results indicated that two subspectra ''a'' and ''b'', corresponding to oxy- and deoxyhemoglobin respectively, were present in all blood samples, and a third subspectrum ''c'' was found to exist in almost all samples from the patients. The parameters of the third subspectra ''c1'' in most samples from the patients were similar to those of carbon monoxyhemoglobin. The components were considered to be the denatured hemoglobin in RBCs (red blood cells). Together with clinical analysis, a possible mechanism of HAPC has been discussed. (orig.)

  10. Mössbauer studies of hemoglobin in high altitude polycythemia

    Xiufang, Zhang; Linming, Shen; Songsen, Chen; Yuanyuan, Liu; Naifei, Gao; Yuanming, Zheng; Zhaohui, Ao; Liangquan, Shong

    1990-07-01

    The Mössbauer spectra have been measured in erythrocytes from normal adults and the patients with high altitude polycythemia (HAPC). The results indicated that two subspectra “a” and “b”, corresponding to oxy- and deoxyhemoglobin respectively, were present in all blood samples, and a third subspectrum “c” was found to exist in almost all samples from the patients. The parameters of the third subspectra “cl” in most samples from the patients were similar to those of carbon monoxyhemoglobin. The components were considered to be the denatured hemoglobin in RBCs (red blood cells). Together with clinical analysis, a possible mechanism of HAPC has been discussed.

  11. Molecular and cellular pathogenesis of hemoglobin SC disease.

    Bunn, H F; Noguchi, C T; Hofrichter, J; Schechter, G P; Schechter, A N; Eaton, W A

    1982-01-01

    Solution and cell studies were performed to ascertain why individuals with hemoglobin (Hb) SC have disease whereas those with Hb AS do not. The polymerization of deoxygenated mixtures containing sickle cell Hb (Hb S; alpha 2 beta 2(6)Glu leads to Val) and Hb C (alpha 2 beta 2(6)Glu leads to Lys) was investigated by measurements of delay times and solubilities. In mixtures containing more than 40% Hb S, polymerization takes place by the same mechanism as in solutions of Hb S alone, with no evi...

  12. Modeling hemoglobin at optical frequency using the unconditionally stable fundamental ADI-FDTD method.

    Heh, Ding Yu; Tan, Eng Leong

    2011-04-12

    This paper presents the modeling of hemoglobin at optical frequency (250 nm - 1000 nm) using the unconditionally stable fundamental alternating-direction-implicit finite-difference time-domain (FADI-FDTD) method. An accurate model based on complex conjugate pole-residue pairs is proposed to model the complex permittivity of hemoglobin at optical frequency. Two hemoglobin concentrations at 15 g/dL and 33 g/dL are considered. The model is then incorporated into the FADI-FDTD method for solving electromagnetic problems involving interaction of light with hemoglobin. The computation of transmission and reflection coefficients of a half space hemoglobin medium using the FADI-FDTD validates the accuracy of our model and method. The specific absorption rate (SAR) distribution of human capillary at optical frequency is also shown. While maintaining accuracy, the unconditionally stable FADI-FDTD method exhibits high efficiency in modeling hemoglobin.

  13. The Use of Quality Benchmarking in Assessing Web Resources for the Dermatology Virtual Branch Library of the National electronic Library for Health (NeLH)

    Boulos, MN Kamel; Roudsari, AV; Gordon, C; Gray, JA Muir

    2001-01-01

    Background In 1998, the U.K. National Health Service Information for Health Strategy proposed the implementation of a National electronic Library for Health to provide clinicians, healthcare managers and planners, patients and the public with easy, round the clock access to high quality, up-to-date electronic information on health and healthcare. The Virtual Branch Libraries are among the most important components of the National electronic Library for Health . They aim at creating online kno...

  14. Heterozygote Hemoglobin G-Coushatta as the Cause of a Falsely Decreased Hemoglobin A1C in an Ion-Exchange HPLC Method

    Kurtoğlu Ayşegül Uğur

    2017-09-01

    Full Text Available Glycated hemoglobin (HbA1c is used for the assessment of glycemic control in patients with diabetes. The presence of genetic variants of hemoglobin can profoundly affect the accuracy of HbA1c measurement. Here, we report two cases of Hemoglobin G-Coushatta (HBB:c.68A>C variant that interferes in the measurement of HbA1c by a cation-exchange HPLC (CE-HPLC method. HbA1c was measured by a CE-HPLC method in a Tosoh HLC-723 G7 instrument. The HbA1c levels were 2.9% and 4%. These results alerted us to a possible presence of hemoglobinopathy. In the hemoglobin variant analysis, HbA2 levels were detected as 78.3% and 40.7% by HPLC using the short program for the Biorad Variant II. HbA1c levels were measured by an immunoturbidimetric assay in a Siemens Dimension instrument. HbA1c levels were reported as 5.5% and 5.3%. DNA mutation analysis was performed to detect the abnormal hemoglobin variant. Presence of Hemoglobin G-Coushatta variant was detected in the patients. The Hb G-Coushatta variants have an impact on the determination of glycated hemoglobin levels using CEHPLC resulting in a false low value. Therefore, it is necessary to use another measurement method.

  15. Genetic and developmental variation of hemoglobin in the deermouse, Peromyscus maniculatus.

    Maybank, K M; Dawson, W D

    1976-04-01

    A genetic investigation of electrophoretic hemoglobin variants of the deermouse, Peromyscus maniculatus, shows three alleles, Hblf, Hblr, and Hblo, at a duplicated site controlling the six adult phenotypes. The Hblf allele has not been described previously. The hemoglobin locus is not closely linked to the albino locus. Fetal hemoglobin is distinct from any of the adult components and has a slower electrophoretic mobility. The fetal phenotype changes to the adult type between the days 15 and 18 of prenatal life.

  16. Quantitative analysis of composition, structure and features of hemoglobin under the influence of radiation in vivo

    Kurbanov, F.F.; Mamedov, T.G.; Abdullaev, Kh.D.; Akhmedov, N.A.; Manojlov, S.K.

    1995-01-01

    The literature data on the changes in composition, structure and properties of hemoglobin under the influence of ionizing radiation in vivo are reviewed. The algorithm of calculation of damaged hemoglobin molecule percentage is proposed. Four main realizations of radiation-chemical damage are considered. By the algorithm the estimation of the damaged molecules percentage resulted from the exposure to 10 Gy is given. Hemoglobin radiation damage is considered as one of the most important mechanisms triggering radiation sickness. 11 refs

  17. Structure of Greyhound hemoglobin: origin of high oxygen affinity.

    Bhatt, Veer S; Zaldívar-López, Sara; Harris, David R; Couto, C Guillermo; Wang, Peng G; Palmer, Andre F

    2011-05-01

    This study presents the crystal structure of Greyhound hemoglobin (GrHb) determined to 1.9 Å resolution. GrHb was found to crystallize with an α₁β₁ dimer in the asymmetric unit and belongs to the R2 state. Oxygen-affinity measurements combined with the fact that GrHb crystallizes in the R2 state despite the high-salt conditions used for crystallization strongly indicate that GrHb can serve as a model high-oxygen-affinity hemoglobin (Hb) for higher mammals, especially humans. Structural analysis of GrHb and its comparison with the R2-state of human Hb revealed several regions that can potentially contribute to the high oxygen affinity of GrHb and serve to rationalize the additional stability of the R2-state of GrHb. A previously well studied hydrophobic cluster of bar-headed goose Hb near α119 was also incorporated in the comparison between GrHb and human Hb. Finally, a structural comparison with generic dog Hb and maned wolf Hb was conducted, revealing that in contrast to GrHb these structures belong to the R state of Hb and raising the intriguing possibility of an additional allosteric factor co-purifying with GrHb that can modulate its quaternary structure.

  18. [Hemoglobin and testosterone: importance on high altitude acclimatization and adaptation].

    Gonzales, Gustavo F

    2011-03-01

    The different types of response mechanisms that the organism uses when exposed to hypoxia include accommodation, acclimatization and adaptation. Accommodation is the initial response to acute exposure to high altitude hypoxia and is characterized by an increase in ventilation and heart rate. Acclimatization is observed in individuals temporarily exposed to high altitude, and to some extent, it enables them to tolerate the high altitudes. In this phase, erythropoiesis is increased, resulting in higher hemoglobin and hematocrit levels to improve oxygen delivery capacity. Adaptation is the process of natural acclimatization where genetical variations and acclimatization play a role in allowing subjects to live without any difficulties at high altitudes. Testosterone is a hormone that regulates erythropoiesis and ventilation and could be associated to the processes of acclimatization and adaptation to high altitude. Excessive erythrocytosis, which leads to chronic mountain sickness, is caused by low arterial oxygen saturation, ventilatory inefficiency and reduced ventilatory response to hypoxia. Testosterone increases during acute exposure to high altitude and also in natives at high altitude with excessive erythrocytosis. Results of current research allow us to conclude that increase in serum testosterone and hemoglobin is adequate for acclimatization, as they improve oxygen transport, but not for high altitude adaptation, since high serum testosterone levels are associated to excessive erythrocytosis.

  19. Hemoglobinas anormais e dificuldade diagnóstica Abnormal hemoglobins

    Guilherme G. Leoneli

    2000-12-01

    Full Text Available As hemoglobinas humanas, com padrão de herança definido geneticamente, apresentam variações polimórficas características dentro de nossa população, na dependência dos grupos raciais que formam cada região. Aparecem sob a forma de variantes de hemoglobinas ou talassemias, sendo mais freqüentes, no Brasil, os tipos variantes S e C e as talassemias alfa e beta, todas na forma heterozigota. Durante o ano de 1999, amostras de sangue de 506 indivíduos com anemia a esclarecer ou que já passaram por alguma triagem de hemoglobinopatias foram encaminhadas ao Centro de Referência de Hemoglobinas da UNESP, para confirmação diagnóstica e submetidas a procedimentos eletroforéticos, análises bioquímicas e citológicas, para caracterização das hemoglobinas anormais. O objetivo do presente estudo foi verificar quais tipos de hemoglobinas anormais apresentam maior dificuldade diagnóstica. As amostras foram provenientes de 24 cidades de doze estados. Os resultados mostraram que 354 indivíduos (69,96% apresentaram hemoglobinas anormais, sendo 30 Hb AS (5,93%, 5 Hb AC (0,98%, 76 sugestivos de talassemia alfa heterozigota (15,02%, 134 sugestivos de talassemia beta heterozigota (26,48% e 109 com outras formas de hemoglobinas anormais (21,54%, que incluem variantes raras e interações de diferentes formas de talassemias e hemoglobinas variantes. Concluiu-se que, apesar da melhoria técnica oferecida atualmente e a constante formação de recursos humanos capacitados, as talassemias em sua forma heterozigota (210 indivíduos -- 41,50% são responsáveis pela maior dificuldade diagnóstica, seguido da caracterização de variantes raras e formas interativas de hemoglobinopatias (109 indivíduos -- 21,54%, sugerindo que se deve aumentar a capacidade de formação de pessoal e as informações a respeito destas alterações genéticas em nossa população.The human hemoglobins, with genetically defined inheritance patterns, have shown

  20. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    Manit Nuinoon

    2014-01-01

    Full Text Available Thalassemia and hemoglobin E (Hb E are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were recruited for thalassemia and Hb E screening by red blood cell indices/dichlorophenolindophenol precipitation test. β-Thalassemia and Hb E were then identified by high performance liquid chromatography and 4 common α-thalassemia deletions were characterized by a single tube-multiplex gap-polymerase chain reaction. Overall frequency of hemoglobinopathies was 12.9%, classified as follows: homozygous α-thalassemia 2 (1.7%, heterozygous α-thalassemia 1 (1.7%, heterozygous β-thalassemia without α-thalassemia (0.9%, heterozygous Hb E without α-thalassemia (5.2%, double heterozygotes for Hb E/α-thalassemia 1 (1.7%, homozygous Hb E without α-thalassemia (0.9%, and homozygous Hb E with heterozygous α-thalassemia 2 (0.9%. The usefulness of thalassemia screening is not only for receiving highly effective red blood cells in the recipients but also for encouraging the control and prevention program of thalassemia in blood donors.

  1. Biphasic oxidation of oxy-hemoglobin in bloodstains.

    Rolf H Bremmer

    Full Text Available BACKGROUND: In forensic science, age determination of bloodstains can be crucial in reconstructing crimes. Upon exiting the body, bloodstains transit from bright red to dark brown, which is attributed to oxidation of oxy-hemoglobin (HbO(2 to met-hemoglobin (met-Hb and hemichrome (HC. The fractions of HbO(2, met-Hb and HC in a bloodstain can be used for age determination of bloodstains. In this study, we further analyze the conversion of HbO(2 to met-Hb and HC, and determine the effect of temperature and humidity on the conversion rates. METHODOLOGY: The fractions of HbO(2, met-Hb and HC in a bloodstain, as determined by quantitative analysis of optical reflectance spectra (450-800 nm, were measured as function of age, temperature and humidity. Additionally, Optical Coherence Tomography around 1300 nm was used to confirm quantitative spectral analysis approach. CONCLUSIONS: The oxidation rate of HbO(2 in bloodstains is biphasic. At first, the oxidation of HbO(2 is rapid, but slows down after a few hours. These oxidation rates are strongly temperature dependent. However, the oxidation of HbO(2 seems to be independent of humidity, whereas the transition of met-Hb into HC strongly depends on humidity. Knowledge of these decay rates is indispensable for translating laboratory results into forensic practice, and to enable bloodstain age determination on the crime scene.

  2. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    Kruachan, Kwanta; Sengking, Warachaya; Horpet, Dararat; Sungyuan, Ubol

    2014-01-01

    Thalassemia and hemoglobin E (Hb E) are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were recruited for thalassemia and Hb E screening by red blood cell indices/dichlorophenolindophenol precipitation test. β-Thalassemia and Hb E were then identified by high performance liquid chromatography and 4 common α-thalassemia deletions were characterized by a single tube-multiplex gap-polymerase chain reaction. Overall frequency of hemoglobinopathies was 12.9%, classified as follows: homozygous α-thalassemia 2 (1.7%), heterozygous α-thalassemia 1 (1.7%), heterozygous β-thalassemia without α-thalassemia (0.9%), heterozygous Hb E without α-thalassemia (5.2%), double heterozygotes for Hb E/α-thalassemia 1 (1.7%), homozygous Hb E without α-thalassemia (0.9%), and homozygous Hb E with heterozygous α-thalassemia 2 (0.9%). The usefulness of thalassemia screening is not only for receiving highly effective red blood cells in the recipients but also for encouraging the control and prevention program of thalassemia in blood donors. PMID:25050123

  3. Infant Responsiveness, Alertness, Hemoglobin and Growth in Rural Sidama, Ethiopia

    Aubuchon-Endsley, Nicki L.; Grant, Stephanie L.; Thomas, David G.; Kennedy, Tay S.; Berhanu, Getenesh; Stoecker, Barbara J.; Hubbs-Tait, Laura; Hambidge, K. Michael

    2011-01-01

    Several recent studies have supported relations between infant behavior (alertness and responsiveness) and nutrition (e.g. Dempsey 2008, Wachs et al 2005) in addition to investigating infant behavior within the context of changes in iron status over time (e.g. Black et al. 2004, Murray-Kolb & Beard 2009). Existing research is typically limited to investigation of the effects of a single vitamin or mineral and no studies have been found that examined the influence that early alertness and responsiveness have on growth in early infancy, despite the fact that relations between behavior and nutritional status may be bidirectional (Hulthén 2003). The current study used a sample of Ethiopian infants and investigated anthropometrics, hemoglobin, the frequency of alertness, and the frequency of responsiveness at 6 and 9 months of age. Six-month weight-for-age predicted 9-month frequency of alertness, while 6-month hemoglobin predicted 9-month frequency of responsiveness. Compared to responsive infants, non-responsive infants at 6 months remained more non-responsive at 9 months, though weight-for-age for both groups converged at 9 months. Results support relations between nutrition and behavior (alertness and responsiveness) and provide evidence of a potentially useful tool (the Laboratory Temperament Assessment Battery [Lab-TAB]) that was adapted to evaluate these relations in Ethiopia. PMID:22233352

  4. Multiwavelength pulse oximetry in the measurement of hemoglobin fractions

    Manzke, Bernd; Schwider, Johannes; Lutter, Norbert O.; Engelhardt, Kai; Stork, Wilhelm

    1996-04-01

    The two wavelength design of the majority of pulse oximeters assumes only two absorbing hemoglobin fractions, oxyhemoglobin (O2Hb), and reduced hemoglobin (HHb) irrespective of the presence of methemoglobin (MetHb) and carboxyhemoglobin (COHb). If MetHb or COHb is present, it contributes to the pulse-added absorbance signal and will be interpreted as either HHb or O2Hb or some combination of the two. In this paper we describe a noninvasive multi-wavelength pulse oximeter measuring O2Hb, HHb, MetHb, and COHb at a specified accuracy of 1.0%. The system was designed with respect to the results of numerical simulations. It consists of 9 laserdiodes (LDs) and 7 light emitting diodes (LEDs), a 16-bit analog-digital converter (ADC) and has a sampling rate of 16 kHz. The laser didoes and LEDs were coupled into multi-mode fibers and led with a liquid lightguide to the finger clip and then the photodiode. It also presents the results of a clinical study, including a setup with a quartz tungsten halogen lamp (with fiber output) and a diode array spectrometer, a standard pulse oximeter and two in-vitro oximeters (radiometer OSM3 and radiometer ABL 520) as references.

  5. Moessbauer spectroscopic studies of hemoglobin and its isolated subunits

    Hoy, G.R.; Cook, D.C.; Berger, R.L.; Friedman, F.K.

    1986-01-01

    Samples of 90% enriched 57Fe hemoglobin and its isolated subunits have been prepared. Moessbauer spectroscopic measurements have been made on three such samples. Sample one contained contributions of oxyhemoglobin, deoxyhemoglobin, and carbonmonoxyhemoglobin. This sample was studied from a temperature of 90 K down to 230 mK. Measurements were also made at 4.2 K using a small applied magnetic field of 1.0 T. In general, the measured quadrupole splittings and isomer shifts for each component agreed with previous measurements on single component samples in the literature, and thus demonstrated that chemically enriched hemoglobin has not been altered. The second and third samples were isolated alpha and beta subunits, respectively. We have found measurable Moessbauer spectral differences between the HbO 2 sites in the alpha subunit sample and the beta subunit sample. The measured Moessbauer spectral areas indicate that the iron ion has the largest mean-square displacement at the deoxy Hb sites as compared to that at the oxy- and carbonmonoxy Hb sites. The mean-square displacement at the HbO 2 sites is the smallest

  6. Oxidative stress in preeclampsia and the role of free fetal hemoglobin

    Stefan Rocco Hansson

    2015-01-01

    Full Text Available Preeclampsia is a leading cause of pregnancy complications and affects 3–7 % of pregnant women. This review summarizes the current knowledge of a new potential etiology of the disease, with a special focus on hemoglobin-induced oxidative stress. Furthermore, we also suggest hemoglobin as a potential target for therapy. Gene and protein profiling studies have shown increased expression and accumulation of free fetal hemoglobin in the preeclamptic placenta. Predominantly due to oxidative damage to the placental barrier, fetal hemoglobin leaks over to the maternal circulation. Free hemoglobin and its metabolites are toxic in several ways; a ferrous hemoglobin (Fe2+ binds strongly to the vasodilator nitric oxide and reduces the availability of free nitric oxide, which results in vasoconstriction, b hemoglobin (Fe2+ with bound oxygen spontaneously generates free oxygen radicals and c the heme groups create an inflammatory response by inducing activation of neutrophils and cytokine production. The endogenous protein α1-microglobulin, with radical and heme binding properties, has shown both ex vivo and in vivo to have the ability to counteract free hemoglobin-induced placental and kidney damage. Oxidative stress in general, and more specifically fetal hemoglobin-induced oxidative stress, could play a key role in the pathology of preeclampsia seen both in the placenta and ultimately in the maternal endothelium.

  7. In vivo integrated photoacoustic and confocal microscopy of hemoglobin oxygen saturation and oxygen partial pressure.

    Wang, Yu; Hu, Song; Maslov, Konstantin; Zhang, Yu; Xia, Younan; Wang, Lihong V

    2011-04-01

    We developed dual-modality microscope integrating photoacoustic microscopy (PAM) and fluorescence confocal microscopy (FCM) to noninvasively image hemoglobin oxygen saturation (sO₂) and oxygen partial pressure (pO₂) in vivo in single blood vessels with high spatial resolution. While PAM measures sO₂ by imaging hemoglobin optical absorption at two wavelengths, FCM quantifies pO₂ using phosphorescence quenching. The variations of sO₂ and pO₂ values in multiple orders of vessel branches under hyperoxic (100% oxygen) and normoxic (21% oxygen) conditions correlate well with the oxygen-hemoglobin dissociation curve. In addition, the total concentration of hemoglobin is imaged by PAM at an isosbestic wavelength.

  8. Purification, characterization and sequence analyses of the extracellular giant hemoglobin from Oligobrachia mashikoi

    Nakagawa, Taro; Onoda, Seiko; Kanemori, Masaaki; Sasayama, Yuichi; Fukumori, Yoshihiro

    2005-01-01

    We purified an extracellular hemoglobin with the molecular mass of ca. 440 kDa from the whole homogenates of Oligobrachia mashikoi (phylum Pogonophora) by a one-step gel-filtration. The preparation was pure to be crystallized. The P50 values of the hemoglobin and the fresh blood prepared from O. mashikoi were about 0.82 Torr and 0.9 Torr, respectively, which were much lower than the P50 value of human hemoglobin. However, the n values of the hemoglobin and the blood were about 1.2 and 1.1, re...

  9. An analysis of postoperative hemoglobin levels in patients with a fractured neck of femur.

    Nagra, Navraj S; van Popta, Dmitri; Whiteside, Sigrid; Holt, Edward M

    2016-10-01

    The aim of this study was to analyze the changes in hemoglobin level and to determine a suitable timeline for post-operative hemoglobin monitoring in patients undergoing fixation of femoral neck fracture. Patients who underwent either dynamic hip screw (DHS) fixation (n = 74, mean age: 80 years) or hip hemiarthroplasty (n = 104, mean age: 84 years) for femoral neck fracture were included into the study. The hemoglobin level of the patients was monitored perioperatively. Analysis found a statistically and clinically significant mean drop in hemoglobin of 31.1 g/L over time from pre-operatively (D0) to day-5 post-operatively (p hemoglobin values over hemiarthroplasty patients (p = 0.046). The decrease in hemoglobin in the first 24-h post-operative period (D0 to day-1) is an underestimation of the ultimate lowest value in hemoglobin found at day-2. Relying on the day-1 hemoglobin could be detrimental to patient care. We propose a method of predicting patients likely to be transfused, and recommend a protocol for patients undergoing femoral neck fracture surgery to standardize postoperative hemoglobin monitoring. Level IV Prognostic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  10. Analysis on Current Situation and Countermeasure of Domestic Electronic Commerce Logistics in the Internet Age——Based on Resource Dependence Theory

    Zhang Jiapeng

    2017-01-01

    Full Text Available This paper analyzes the status of electric business logistics in the current Internet era in China, and combines the SWOT analysis with AHP to do the empirical analysis, then puts forward the countermeasure that the electric business logistics resource should be shared based on the resource dependence theory. Through the empirical analysis, it is found that the disadvantages and opportunities of the logistics status are important in the Internet era.The resource sharing strategy based on the resource dependence theory is more scientific. The rational use of Internet technology in electric business logistics industry can achieve “sharing”. It is of great significance for its balanced development, intelligent development and optimization and development.

  11. Removal of cellular-type hemoglobin-based oxygen carrier (hemoglobin-vesicles) from blood using centrifugation and ultrafiltration.

    Sakai, Hiromi; Sou, Keitaro; Horinouchi, Hirohisa; Tsuchida, Eishun; Kobayashi, Koichi

    2012-02-01

    The hemoglobin-vesicle (HbV) is an artificial oxygen carrier encapsulating a concentrated hemoglobin solution in a phospholipid vesicle (liposome). During or after transporting oxygen, macrophages capture HbVs in the reticuloendothelial system (RES) with an approximate circulation half-life of 3 days. Animal studies show transient splenohepatomegaly after large doses, but HbVs were completely degraded, and the components were excreted in a few weeks. If a blood substitute is used for emergency use until red blood cell transfusion becomes available or for temporary use such as a priming fluid for an extracorporeal circuit, then one option would be to remove HbVs from the circulating blood without waiting a few weeks for removal by the RES. Using a mixture of beagle dog whole blood and HbV, we tested the separation of HbV using a centrifugal Fresenius cell separator and an ultrafiltration system. The cell separator system separated the layers of blood cell components from the HbV-containing plasma layer by centrifugal force, and then the HbV was removed from plasma phase by the ultrafiltration system. The HbVs (250-280 nm) are larger than plasma proteins (blood cell components (> 3 µm). The size of HbVs is advantageous to be separated from the original blood components, and the separated blood components can be returned to circulation. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Magnetic-graphene based molecularly imprinted polymer nanocomposite for the recognition of bovine hemoglobin.

    Guo, Junxia; Wang, Yuzhi; Liu, Yanjin; Zhang, Cenjin; Zhou, Yigang

    2015-11-01

    The protein imprinted technique combining surface imprinting and nanomaterials has been an attractive strategy for recognition and rapid separation of proteins. In this work, magnetic-graphene (MG) was chosen as the supporting substrate for the magnetic nanomaterials, which served to absorb the targeting imprinting molecules, bovine hemoglobin (BHb). Acryl amide (AAm) with a high affinity to BHb and N,N'- methylenebisacrylamide (MBA) were selected as the functional monomer and cross-linking agent, respectively. After in-situ polymerization, the proposed magnetic-graphene based molecularly imprinted polymer (MG-MIP) was obtained with a further extraction step of imprinted BHb. Fourier transform infrared (FT-IR), scanning electron microscopy (SEM), transmission electron microscopy (TEM), raman spectroscopy(RS), X-ray diffraction (XRD) and vibrating sample magnetometer (VSM) were employed to characterize the resulted MG-MIP. The maximum adsorption capability (Qmax) was determined by Langmuir Isotherm Plots and was 186.73 mg/g for imprinted nanomaterials (MIP) with an imprinting factor of 1.96. The selectivity of MG-MIP was investigated by using several proteins that are different in molecular mass and isoelectric points as the reference. The results showed that the shape memory effect of imprinted cavities, the size of proteins and the charge effect of proteins were the major factors for the selective recognition. The proposed method was also employed to specifically capture BHb from a binary protein mixture. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Potential application of hemoglobin as an alternative to peroxidase in a phenol biosensor

    Kafi, A.K.M.; Lee, Dong-Yun; Park, Sang-Hyun; Kwon, Young-Soo

    2008-01-01

    This work describes a new amperometric biosensor for detecting phenolic compounds. The sensor was designed by immobilizing Hemoglobin (Hb) in a sol-gel matrix onto a carbon electrode. Using the peroxidase activity of Hb, the phenolic compound can be reduced in the presence of H 2 O 2 . The biosensor's performance in phenolic compound detection was based on mediated electron transfer by Hb. The direct electron transfer of Hb can be avoided by use of the sol-gel matrix. The proposed biosensor presents a very sensitive response for phenolic compounds at an applied potential of 0.0 mV vs. Ag/AgCl. The parameters of the fabrication process for the electrode were optimized. Experimental conditions influencing the biosensor performance, such as pH and potential, were investigated and assessed. Various types of phenolic compounds were detected. Among them, using the optimized conditions, a linearity for the detection of the phenol was observed from 5 μM to 50 μM. Biosensor response levels after 30 days were at more than 80% of their initial response readings level. The response time of the biosensor was about 10 s

  14. Immobilization, direct electrochemistry and electrocatalysis of hemoglobin on colloidal silver nanoparticles-chitosan film

    Yu Chunmei [College of Chemistry and Chemical Engineering and Materials Science, Suzhou University, Suzhou 215123 (China); Institute of Analytical Chemistry for Life Science, School of Public Health, Nantong University, Nantong 226007 (China); Zhou Xiaohui [Institute of Analytical Chemistry for Life Science, School of Public Health, Nantong University, Nantong 226007 (China); Gu Haiying, E-mail: hygu@ntu.edu.c [Institute of Analytical Chemistry for Life Science, School of Public Health, Nantong University, Nantong 226007 (China)

    2010-12-01

    This paper reports on the fabrication and characterization of hemoglobin (Hb)-colloidal silver nanoparticles (CSNs)-chitosan film on the glassy carbon electrode and its application on electrochemical biosensing. CSNs could greatly enhance the electron transfer reactivity of Hb as a bridge. In the phosphate buffer solution with pH value of 7.0, Hb showed a pair of well-defined redox peaks with the formal potential (E{sup 0'}) of -0.325 V (vs. SCE). The immobilized Hb in the film maintained its biological activity, showing a surface-controlled process with the heterogeneous electron transfer rate constant (k{sub s}) of 1.83 s{sup -1} and displayed the same features of a peroxidase in the electrocatalytic reduction of oxygen and hydrogen peroxide (H{sub 2}O{sub 2}). The linear range for the determination of H{sub 2}O{sub 2} was from 0.75 {mu}M to 0.216 mM with a detection limit of 0.5 {mu}M (S/N = 3). Such a simple assemble method could offer a promising platform for further study on the direct electrochemistry of other redox proteins and the development of the third-generation electrochemical biosensors.

  15. Reactivation of fetal hemoglobin in thalassemia and sickle cell disease

    Sandro Eridani

    2014-09-01

    Full Text Available Considerable attention has been recently devoted to mechanisms involved in the perinatal hemoglobin switch, as it was long ago established that the survival of fetal hemoglobin (HbF production in significant amount can reduce the severity of the clinical course in severe disorders like β-thalassemia and sickle cell disease (SCD. For instance, when β-thalassemia is associated with hereditary persistence of fetal hemoglobin (HPFH the disease takes a mild course, labeled as thalassemia intermedia. The same clinical amelioration occurs for the association between HPFH and SCD. As for the mechanism of this effect, some information has been obtained from the study of natural mutations at the human β-globin locus in patients with increased HbF, like the Corfu thalassemia mutations. Important evidence came from the discovery that drugs capable of improving the clinical picture of SCD, like decitabine ad hydroxycarbamide, are acting through the reactivation, to some extent, of HbF synthesis. The study of the mechanism of action of these compounds was followed by the identification of some genetic determinants, which promote this event. In particular, among a few genetic factors involved in this process, the most relevant appears the BCL11A gene, which is now credited to be able to silence γ-globin genes in the perinatal period by interaction with several erythroid-specific transcription factors and is actually considered as a barrier to HbF reactivation by known HbF inducing agents. Epigenetics is also a player in the process, mainly through DNA demethylation. This is certified by the recent demonstration that hypomethylating agents such as 5-azacytidine and decitabine, the first compounds used for HbF induction by pharmacology, act as irreversible inhibitors of demethyltransferase enzymes. Great interest has also been raised by the finding that several micro-RNAs, which act as negative regulators of gene expression, have been implicated in the

  16. Hemoglobin oxygen affinity in patients with cystic fibrosis.

    Dieter Böning

    Full Text Available In patients with cystic fibrosis lung damages cause arterial hypoxia. As a typical compensatory reaction one might expect changes in oxygen affinity of hemoglobin. Therefore position (standard half saturation pressure P50st and slope (Hill's n of the O2 dissociation curve as well as the Bohr coefficients (BC for CO2 and lactic acid were determined in blood of 14 adult patients (8 males, 6 females and 14 healthy controls (6 males, 8 females. While Hill's n amounted to approximately 2.6 in all subjects, P50st was slightly increased by 1 mmHg in both patient groups (controls male 26.7 ± 0.2, controls female 27.0 ± 0.1, patients male 27.7 ± 0.5, patients female 28.0 ± 0.3 mmHg; mean and standard error, overall p<0.01. Main cause was a rise of 1-2 µmol/g hemoglobin in erythrocytic 2,3-biphosphoglycerate concentration. One patient only, clearly identified as an outlier and with the mutation G551D, showed a reduction of both P50st (24.5 mmHg and [2,3-biphosphoglycerate] (9.8 µmol/g hemoglobin. There were no differences in BCCO2, but small sex differences in the BC for lactic acid in the controls which were not detectable in the patients. Causes for the right shift of the O2 dissociation curve might be hypoxic stimulation of erythrocytic glycolysis and an increased red cell turnover both causing increased [2,3-biphosphoglycerate]. However, for situations with additional hypercapnia as observed in exercising patients a left shift seems to be a more favourable adaptation in cystic fibrosis. Additionally when in vivo PO2 values were corrected to the standard conditions they mostly lay left of the in vitro O2 dissociation curve in both patients and controls. This hints to unknown fugitive factors influencing oxygen affinity.

  17. Hair cortisol concentration and glycated hemoglobin in African American adults.

    Lehrer, H Matthew; Dubois, Susan K; Maslowsky, Julie; Laudenslager, Mark L; Steinhardt, Mary A

    2016-10-01

    African Americans have higher diabetes prevalence compared to Whites. They also have elevated cortisol levels - indicating possible HPA axis dysregulation - which may raise blood glucose as part of the biological response to physiological and psychosocial stress. Little is known about chronic cortisol levels in African Americans, and even less about the role of chronically elevated cortisol in type 2 diabetes development in this racial group. We used analysis of cortisol in hair to examine associations of long-term (∼3months) cortisol levels with glycated hemoglobin (HbA1c) in a group of African American adults. In exploratory analyses, we also studied the relationship of hair dehydroepiandrosterone (DHEA) with HbA1c. Participants were 61 community-dwelling African American adults (85% female; mean age 54.30 years). The first 3cm of scalp-near hair were analyzed for cortisol and DHEA concentration using enzyme-linked immunoassay analysis. Glycated hemoglobin was assessed, and regression analyses predicting HbA1c from hair cortisol and DHEA were performed in the full sample and in a subsample of participants (n=20) meeting the National Institute of Diabetes and Digestive Kidney Disease (NIDDK) criteria for type 2 diabetes (HbA1c≥6.5%). In the full sample, HbA1c increased with hair cortisol level (β=0.22, p=0.04, f(2)=0.10), independent of age, sex, chronic health conditions, diabetes medication use, exercise, and depressive symptoms. In the subsample of participants with an HbA1c≥6.5%, hair cortisol was also positively related to HbA1c (β=0.45, p=0.04, f(2)=0.32), independent of diabetes medication use. Glycated hemoglobin was unrelated to hair DHEA in both the full sample and HbA1c≥6.5% subsample. Long-term HPA axis dysregulation in the form of elevated hair cortisol is associated with elevated HbA1c in African American adults. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. TRUNCATED OR 2/2 HEMOGLOBINS : A NEW CLASS OF GLOBINS WITH NOVEL STRUCTURE AND FUNCTION

    Amit Kumar

    2013-06-01

    Full Text Available Bright red hemoglobins, the most well-known paradigm in protein science, seem to be ubiquitous in nature. With advances in modern tools and techniques, discovery of new globins at a rapid pace has expanded this family. With every discovery, new insights emerged regarding their novel structure, function and several other characteristics previously not observed for hemoglobins. Even the classical function unanimously assigned to hemoglobins – oxygen transport and storage – needed re-evaluation. The ability of this class of proteins to show responses against various gaseous ligands, even the poisonous ones, indicate that it is obviously as ancient as life. As organisms evolved, hemoglobins also evolved, and accumulated a great degree of diversity in all aspects. The classical globin fold is very unique with 3-on-3 alpha helical bundle as observed in the traditional oxygen-transport hemoglobins like myoglobin, human blood hemoglobin and leghemoglobins in plants. However, a class of the newly discovered hemoglobins, which dominate the superfamily and appears ancient in origin mostly have 2-on-2 fold, commonly termed as “truncated” hemoglobins. These hemoglobins are phylogenetically distinct from their classical counterparts and are often shorter in their polypeptide length by 20-40 residues mainly due to a lack of short A helix, D helix and F helix. However, hemoglobins with 2-on-2 fold were also later found to have polypeptide chain lengths similar in size to classical globins. Disordered pre-F helix region, conserved glycine motifs and other key residues and apolar tunnels through their protein matrix for migration of ligands are some unique characteristics features of these truncated hemoglobins. Some of these are also hexacoordinated at heme iron where an amino acid from within the protein coordinates heme iron in absence of a ligand. These hemoglobins are well known for their high affinity towards ligand and have a diverse mechanism of

  19. Electron microscope studies

    Crewe, A.V.; Kapp, O.H.

    1990-01-01

    Our laboratory has made significant progress this year in devising improved electron-optical systems, in studying invertebrate hemoglobins with the STEM, and in achieving a workable sub-angstrom STEM. Our goal in electron optics is to improve resolution by producing spherical and chromatic aberration coefficients with signs opposite those of magnetic lenses. We have progressed toward this goal through calculations that explore the addition of electrodes to electron mirrors to reduce these two geometric aberrations and by devising a beam separation system that won't introduce asymmetrical aberrations. Some promising new designs of magnetic lenses for SEM applications have also been investigated. We have continued our exploration of the quaternary structure of the invertebrate hemoglobins and are now among the top laboratories in this area of expertise. In addition, we have overcome many of our electronic difficulties on the sub-angstrom STEM and have made significant progress toward achieving an operational system. The addition of an IBM RISC-6000 workstation to our lab has significantly increased our image processing capabilities

  20. Moessbauer studies of hemoglobin in erythrocytes exposed to neutron radiation

    Niemiec, Katarzyna; Kaczmarska, Magdalena; Buczkowski, Mateusz [AGH University, Faculty of Physics and Computer Science, Department of Medical Physics and Biophysics (Poland); Fornal, Maria [Collegium Medicum, Jagiellonian University, Department of Internal Medicine and Gerontology (Poland); Pohorecki, Wladyslaw [AGH University, Faculty of Energy and Fuels (Poland); Matlak, Krzysztof; Korecki, Jozef [AGH University, Faculty of Physics and Computer Science, Department of Solid State Physics (Poland); Grodzicki, Tomasz [Collegium Medicum, Jagiellonian University, Department of Internal Medicine and Gerontology (Poland); Burda, Kvetoslava, E-mail: kvetoslava.burda@fis.agh.edu.pl [AGH University, Faculty of Physics and Computer Science, Department of Medical Physics and Biophysics (Poland)

    2012-03-15

    We studied radiation effects on the stability of various states of hemoglobin (Hb) in red blood cells (RBC) irradiated with a very low dose of neutron rays, 50 {mu}Gy. We investigated RBCs isolated from blood of healthy donors. Moessbauer spectroscopy was applied to monitor different forms of Hb. Our results show, for the first time, that oxyhemoglobin (OxyHb) and deoxyhemoglobin (DeoxyHb) are two Hb forms sensitive to such a low neutron radiation. Both Hbs change into a new Hb form (Hb{sub irr}). Additionally, OxyHb transfers into HbOH/H{sub 2}O, which under our experimental conditions is resistant to the action of neutron rays.

  1. Effects of Hemoglobin-Based Oxygen Carriers on Blood Coagulation

    Kimia Roghani

    2014-12-01

    Full Text Available For many decades, Hemoglobin-based oxygen carriers (HBOCs have been central in the development of resuscitation agents that might provide oxygen delivery in addition to simple volume expansion. Since 80% of the world population lives in areas where fresh blood products are not available, the application of these new solutions may prove to be highly beneficial (Kim and Greenburg 2006. Many improvements have been made to earlier generation HBOCs, but various concerns still remain, including coagulopathy, nitric oxide scavenging, platelet interference and decreased calcium concentration secondary to volume expansion (Jahr et al. 2013. This review will summarize the current challenges faced in developing HBOCs that may be used clinically, in order to guide future research efforts in the field.

  2. Hemoglobin-catalyzed fluorometric method for the determination of glutathione

    Wang, Ruiqiang; Tang, Lin; Li, Hua; Wang, Yi; Gou, Rong; Guo, Yuanyuan; Fang, Yudong; Chen, Fengmei

    2016-01-01

    A new spectrofluorometric method for the determination of glutathione based on the reaction catalyzed by hemoglobin was reported. The reaction product gave a highly fluorescent intensity with the excitation and emission wavelengths of 320.0 nm and 413.0 nm, respectively. The optimum experimental conditions were investigated. Results showed that low concentration glutathione enhanced the fluorescence intensity significantly. The line ranges were 1.0 × 10-6-1.0 × 10-5 mol L-1 of glutathione and 6.0 × 10-10 mol L-1-1.0 × 10-8 mol L-1, respectively. The detection limit was calculated to be 1.1 × 10-11 mol L-1. The recovery test by the standard addition method gave values in the range of 90.78%-102.20%. This method was used for the determination of glutathione in synthetic and real samples with satisfactory results.

  3. Expression and purification of recombinant hemoglobin in Escherichia coli

    Natarajan, Chandrasekhar; Jiang, Xiaoben; Fago, Angela

    2011-01-01

    BACKGROUND: Recombinant DNA technologies have played a pivotal role in the elucidation of structure-function relationships in hemoglobin (Hb) and other globin proteins. Here we describe the development of a plasmid expression system to synthesize recombinant Hbs in Escherichia coli, and we describe...... a protocol for expressing Hbs with low intrinsic solubilities. Since the alpha- and beta-chain Hbs of different species span a broad range of solubilities, experimental protocols that have been optimized for expressing recombinant human HbA may often prove unsuitable for the recombinant expression......-translational modifications. CONCLUSION/SIGNIFICANCE: Our protocol should prove useful for the experimental study of recombinant Hbs in many non-human animals. One of the chief advantages of our protocol is that we can express soluble recombinant Hb without co-expressing molecular chaperones, and without the need...

  4. Symbiotic and nonsymbiotic hemoglobin genes of Casuarina glauca

    Jacobsen-Lyon, K; Jensen, Erik Østergaard; Jørgensen, Jan-Elo

    1995-01-01

    Frankia. Both the nonsymbiotic and symbiotic genes retained their specific patterns of expression when introduced into the legume Lotus corniculatus. We interpret this finding to mean that the controls of expression of the symbiotic gene in Casuarina must be similar to the controls of expression...... of the leghemoglobin genes that operate in nodules formed during the interaction between rhizobia and legumes. Deletion analyses of the promoters of the Casuarina symbiotic genes delineated a region that contains nodulin motifs identified in legumes; this region is critical for the controlled expression...... of the Casuarina gene. The finding that the nonsymbiotic Casuarina gene is also correctly expressed in L. corniculatus suggests to us that a comparable non-symbiotic hemoglobin gene will be found in legume species. Udgivelsesdato: 1995-Feb...

  5. Growth stimulation of Porphyromonas endodontalis by hemoglobin and protoporphyrin IX.

    Zerr, M A; Cox, C D; Johnson, W T; Drake, D R

    2000-12-01

    Porphyromonas endodontalis, like other Porphyromonas species, has a complex set of nutritional requirements. In addition to being an obligate anaerobe, the bacterium must be grown in a complex medium consisting of amino acids, reducing agents and heme compounds. P. endodontalis accumulates high concentrations of heme pigments to the extent that colonies appear black on blood agar. This accumulation of heme and the need for these compounds has been characterized as iron requirements by these species. However, in our studies, P. endodontalis demonstrated growth dependence on hemoglobin or protoporphyrin IX but not on free iron. Iron added to other heme compounds actually decreased growth stimulation by porphyrin-containing compounds. P. endodontalis actively transported free iron, but this process did not appear to be critical for growth. The maximum stimulation of growth by protoporphyrin IX, under conditions of iron deprivation, suggests that P. endodontalis requires the porphyrin moiety as a growth factor.

  6. Picosecond transient absorption study of photodissociated carboxy hemoglobin and myoglobin

    Janes, S.M.; Dalickas, G.A.; Eaton, W.A.; Hochstrasser, R.M.

    1988-01-01

    The optical transient absorption spectra at 30 ps and 6.5 ns after photolysis are compared for both carboxy hemoglobin (HbCO) and carboxy myoglobin (MbCO). Both 355- and 532-nm excitation pulses were used. In all cases the shapes of the optical difference spectra thus generated are stationary over the complete time-scale studied. The photolysis spectra for MbCO are not significantly different from the equilibrium difference spectra generated on the same picosecond spectrometer when measured to an accuracy of +/- 0.5 nm. In addition, spectral parameters for delegated HbCO generated on the same spectrometer but detected by two different techniques, either by a Vidicon detector or point by point with photomultiplier tubes, are reported; the results are different from some of the previously reported picosecond experiments

  7. Hemoglobin cut-off values in healthy Turkish infants

    Ahmet Arvas; Emel Gür; DurmuşDoğan

    2014-01-01

    Background: Anemia is a widespread public health problem associated with an increased risk of morbidity and mortality. This study was undertaken to determine the cut-off value of hemoglobin for infant anemia. Methods: A cross-sectional retrospective study was carried out at well-baby clinics of a tertiary care hospital. A total of 1484 healthy infants aged between 4 to 24 months were included in the study. The relationship of hemoglobin (Hb) levels with mother age, birth weight, weight gain rate, feeding, and gender was evaluated. Results: The Hb levels were assessed in four age groups (4 months, 6 months, 9-12 months, and 15-24 months) and the cut-off values of Hb were determined. Hb cut-off values (5th percentile for age) were detected as 97 g/L and 93 g/L at 4 months and 6 months, respectively. In older infants, the 5th percentile was 90.5 g/L and 93.4 g/L at 9-12 months and 15-24 months, respectively. The two values were lower than the World Health Organization criteria for anemia, which could partly due to the lack of information on iron status in our population. However, this difference highlights the need for further studies on normal Hb levels in healthy infants in developing countries. Hb levels of females were higher in all age groups; however, a statistically significant difference was found in gender in only 6 month-old infants. No statistically significant difference was found among Hb levels, mother's age, birth weight, weight gain rate, and nutritional status. Conclusion: Hb cut-off values in infants should be re-evaluated and be compatible with growth and development of children in that community.

  8. Hemoglobin genetics: recent contributions of GWAS and gene editing

    Smith, Elenoe C.; Orkin, Stuart H.

    2016-01-01

    The β-hemoglobinopathies are inherited disorders resulting from altered coding potential or expression of the adult β-globin gene. Impaired expression of β-globin reduces adult hemoglobin (α2β2) production, the hallmark of β-thalassemia. A single-base mutation at codon 6 leads to formation of HbS (α2βS2) and sickle cell disease. While the basis of these diseases is known, therapy remains largely supportive. Bone marrow transplantation is the only curative therapy. Patients with elevated levels of fetal hemoglobin (HbF, α2γ2) as adults exhibit reduced symptoms and enhanced survival. The β-globin gene locus is a paradigm of cell- and developmental stage-specific regulation. Although the principal erythroid cell transcription factors are known, mechanisms responsible for silencing of the γ-globin gene were obscure until application of genome-wide association studies (GWAS). Here, we review findings in the field. GWAS identified BCL11A as a candidate negative regulator of γ-globin expression. Subsequent studies have established BCL11A as a quantitative repressor. GWAS-related single-nucleotide polymorphisms lie within an essential erythroid enhancer of the BCL11A gene. Disruption of a discrete region within the enhancer reduces BCL11A expression and induces HbF expression, providing the basis for gene therapy using gene editing tools. A recently identified, second silencing factor, leukemia/lymphoma-related factor/Pokemon, shares features with BCL11A, including interaction with the nucleosome remodeling deacetylase repressive complex. These findings suggest involvement of a common pathway for HbF silencing. In addition, we discuss other factors that may be involved in γ-globin gene silencing and their potential manipulation for therapeutic benefit in treating the β-hemoglobinopathies. PMID:27340226

  9. Glycated Hemoglobin Levels in Patients with Decompensated Cirrhosis

    Jeffrey Nadelson

    2016-01-01

    Full Text Available Introduction. Aim of this study is to determine if HbA1c levels are a reliable predictor of glycemic control in patients with decompensated cirrhosis. Methods. 200 unique patients referred for liver transplantation at University of Tennessee/Methodist University Transplant Institute with a HbA1c result were included. Three glucose levels prior to the “measured” A1c (MA1c were input into an HbA1c calculator from the American Diabetes Association website to determine the “calculated” A1c (CA1c. The differences between MA1c and CA1c levels were computed. Patients were divided into three groups: group A, difference of 1.5. Results. 97 (49% patients had hemoglobin A1c of less than 5%. Discordance between calculated and measured HbA1c of >0.5% was seen in 47% (n=94. Higher level of discordance of greater than >1.5 was in 12% of patients (n=24. Hemoglobin was an independent predictor for higher discordance (odds ratio 0.77 95%, CI 0.60–0.99, and p value 0.04. HbA1c was an independent predictor of occurrence of HCC (OR 2.69 955, CI 1.38–5.43, and p value 0.008. Conclusion. HbA1c is not a reliable predictor of glycemic control in patients with decompensated cirrhosis, especially in those with severe anemia.

  10. The Determinants of Hemoglobin Variability in Hemodialysis Patients

    Tomanoski Vasilije

    2016-12-01

    Full Text Available Introduction. Factors that have been reported to affect erythropoietin (EPO responsiveness in hemodialysis (HD patients include iron deficiency, chronic inflammation, secondary hyperparathyroidism, malnutrition and inadequate HD dose. The aim of the study was to analyze the deteminants of hemoglobin variability in HD patients. Methods. The study encompassed 526 patients (197 F and 329 M. According to HD vintage at the beginning of the study the patients were divided into two groups: group-1 encompassed 153 patients with HD vintage bellow 24 months, and group-2 encompassed 329 patients with HD vintage over 24 months. Over a period of 21 months after admission the following parameters were analyzed: hemoglobin (Hb, EPO dose, iron dose, HD dose (eKT/V, transferrin saturation (TSAT, C-reactive protein (CRP, ferritin and serum albumin at 3 months and parathyroid hormone (PTH at 6 months. Results. The percentage of patients with Hb>=105g/L significantly improved, and the average Hb level significantly increased in both groups over a period of 21 months. The average EPO and iron dose significantly decreased, but TSAT and ferritin levels significantly increased over a period of 21 months. The average eKT/V and s-albumin values significantly increased, but the average CRP and PTH levels significantly decresead over a period of 21 months. In group-1 EPO dose and CRP, but in group-2 EPO dose, ferritin, HD vintage, and iron dose were statistically significant predictors of the Hb level 9 months after admission. Conclusions. Insufficient EPO therapy, iron deficiency and chronic inflammation were the main factors of inadequate correction of anemia in HD patients before admission.

  11. Pathophysiological consequences of hemolysis. Role of cell-free hemoglobin

    Tomasz Misztal

    2011-09-01

    Full Text Available Abundant hemolysis is associated with a number of inherent and acquired diseases including sickle-cell disease (SCD, polycythemia, paroxysmal nocturnal hemoglobinuria (PNH and drug-induced hemolytic anemia. Despite different etiopathology of hemolytic diseases, many concomitant symptoms are comparable and include e.g. hypertension, hemoglobinuria and hypercoagulation state. Studies in the last years have shown a growing list of mechanisms lying at the basis of those symptoms, in particular irreversible reaction between cell-free hemoglobin (Hb and nitric oxide (NO – endogenous vasorelaxant and anti-thrombotic agent. Saturation of protective physiological cell-free Hb-scavenging mechanisms results in accumulation of Hb in plasma and hemoglobinemia. Extensive hemoglobinemia subsequently leads to hemoglobinuria, which may cause kidney damage and development of Fanconi syndrome. A severe problem in patients with SCD and PNH is pulmonary and systemic hypertension. It may lead to circulation failure, including stroke, and it is related to abolition of NO bioavailability for vascular smooth muscle cells. Thrombotic events are the major cause of death in SCD and PNH. It ensues from lack of platelet inhibition evoked by Hb-mediated NO scavenging. A serious complication that affects patients with excessive hemolysis is erectile dysfunction. Also direct cytotoxic, prooxidant and proinflammatory effects of cell-free hemoglobin and heme compose the clinical picture of hemolytic diseases. The pathophysiological role of plasma Hb, mechanisms of its elimination, and direct and indirect (via NO scavenging deleterious effects of cell-free Hb are presented in detail in this review. Understanding the critical role of hemolysis and cell-free Hb is important in the perspective of treating patients with hemolytic diseases and to design new effective therapies in future.

  12. Mechanisms of the adjuvant effect of hemoglobin in experimental peritonitis. VII. Hemoglobin does not inhibit clearance of Escherichia coli from the peritoneal cavity

    Dunn, D.L.; Barke, R.A.; Lee, J.T. Jr.; Condie, R.M.; Humphrey, E.W.; Simmons, R.L.

    1983-01-01

    Hemoglobin has been shown to be a potent adjuvant in experimental Escherichia coli peritonitis, although a satisfactory mechanistic rationale is still obscure. Hemoglobin has been thought to impair intraperitoneal neutrophil function, delay clearance of bacteria from the peritoneal cavity by the normal absorptive mechanisms, or directly enhance bacterial growth. Using highly purified stroma-free hemoglobin (SFHgb), we have largely discounted any direct effect of hemoglobin on peritoneal white blood cell function. In the present study, we confirmed that uncontrolled proliferation of bacteria takes place in the presence of hemoglobin in the peritoneal cavity. Nonviable 5-iododeoxyuridine 125 I-labelled bacteria were then used to directly study peritoneal clearance kinetics, eliminating the problem of bacterial growth. SFHgb had no influence on the removal of intraperitoneal bacteria. The rate of bloodstream appearance of radiolabel was similar with or without intraperitoneal SFHgb. Thus, SFHgb does not prevent clearance of bacteria from the peritoneal cavity by interfering with normal host clearance mechanisms. SFHgb may act as a bacterial growth adjuvant, either by serving as a bacterial nutrient or by suitably modifying the environment so that extensive bacterial proliferation can occur. The latter hypothesis appears to be an area in which investigation concerning the adjuvant effect of hemoglobin may prove most fruitful

  13. Correlation of Oxygenated Hemoglobin Concentration and Psychophysical Amount on Speech Recognition

    Nozawa, Akio; Ide, Hideto

    The subjective understanding on oral language understanding task is quantitatively evaluated by the fluctuation of oxygenated hemoglobin concentration measured by the near-infrared spectroscopy. The English listening comprehension test wihch consists of two difficulty level was executed by 4 subjects during the measurement. A significant correlation was found between the subjective understanding and the fluctuation of oxygenated hemoglobin concentration.

  14. The impact of hemoglobin levels on patient and graft survival in renal transplant recipients.

    Moore, Jason

    2008-08-27

    It remains unclear whether low hemoglobin levels are associated with increased mortality or graft loss after renal transplantation. This study assessed the relationship of hemoglobin levels with patient and graft survival in 3859 patients with functioning renal transplants more than 6-months posttransplantation.

  15. Possible heterogeneity of centres of binding 1,8-ANS in molecules of oxygenated hemoglobin

    Parul', D.A.; Bokut', S.B.; Milyutin, A.A.; Petrov, E.P.; Nemkovich, N.A.; Sobchuk, A.N.; Dzhagarov, B.M.

    1999-01-01

    Forming of oxygenated hemoglobin is one of effects of ionizing radiation action on organism. It was revealed heterogeneity of centers of binding of 1,8-ANS in intact molecule of oxygenated hemoglobin. Two types of binding centers possible reflect the existence of two regions in protein molecule with different accessibility to molecules of water

  16. Prognostic value of hemoglobin concentration in radiotherapy for cancer of supraglottic larynx

    Tarnawski, Rafal; Skladowski, Krzysztof; Maciejewski, Boguslaw

    1997-01-01

    Purpose: The aim of this work is the estimation of correlations between hemoglobin concentration either before or after radiotherapy and local tumor control probability for laryngeal cancer. Methods and Materials: Retrospective analysis of 847 cases of laryngeal supraglottic squamous cell carcinoma treated with radiation alone was performed using maximum likelihood estimations, and step-wise logistic regression. All patients were in good initial performance status (Karnofsky index >70). The minimum follow-up time was 3 years. Results: Logistic regression showed that the hemoglobin concentration after radiotherapy is an important prognostic factor. There was a very strong correlation between hemoglobin concentration and tumor local control probability. Hemoglobin concentration at the beginning of radiotherapy does not correlate with treatment outcome, but any decrease of hemoglobin during therapy is a strong prognostic factor for treatment failure. Conclusions: Although regression models with many variables may be instable, the present results suggest that hemoglobin concentration after treatment is at least as important as overall treatment time. It was not possible to find out whether the low concentration of hemoglobin is an independent cause of low TCP or whether it reflects other mechanisms that may influence both hemoglobin level and the TCP

  17. 76 FR 51041 - Hemoglobin Standards and Maintaining Adequate Iron Stores in Blood Donors; Public Workshop

    2011-08-17

    ...] Hemoglobin Standards and Maintaining Adequate Iron Stores in Blood Donors; Public Workshop AGENCY: Food and... Donors.'' The purpose of this public workshop is to discuss blood donor hemoglobin and hematocrit qualification standards in the United States, its impact on donor safety and blood availability, and potential...

  18. Enhancement of Salinity Tolerance during Rice Seed Germination by Presoaking with Hemoglobin

    Sheng Xu

    2011-04-01

    Full Text Available Salinity stress is an important environmental constraint limiting the productivity of many crops worldwide. In this report, experiments were conducted to investigate the effects of seed presoaking by bovine hemoglobin, an inducer of heme oxygenase-1 (HO-1, on salinity tolerance in rice (Oryza sativa plants. The results showed that different concentrations of the hemoglobin (0.01, 0.05, 0.2, 1.0, and 5.0 g/L differentially alleviated the inhibition of rice seed germination and thereafter seedling shoot growth caused by 100 mM NaCl stress, and the responses of 1.0 g/L hemoglobin was the most obvious. Further analyses showed that application of hemoglobin not only increased the HO-1 gene expression, but also differentially induced catalase (CAT, ascorbate peroxidase (APX, and superoxide dismutase (SOD activities or transcripts, thus decreasing the lipid peroxidation in germinating rice seeds subjected to salt stress. Compared with non-hemoglobin treatment, hemoglobin presoaking also increased the potassium (K to sodium (Na ratio both in the root and shoot parts after salinity stress. The effect is specific for HO-1 since the potent HO-1 inhibitor zinc protoporphyrin IX (ZnPPIX blocked the positive actions of hemoglobin on seed germination and seedling shoot growth. Overall, these results suggested that hemoglobin performs an advantageous role in enhancement of salinity tolerance during rice seed germination.

  19. Hemoglobin alpha 2 gene +861 G>A polymorphism in Turkish ...

    Thalassemia is an inherited blood disorder which is divided into two groups: alpha and beta. HBA1 and HBA2 are the two genes associated with alpha thalassemia. The aim of this study is to investigate abnormal hemoglobin variants of alpha globin gene in healthy abnormal hemoglobin carrying individuals with intact beta ...

  20. Molecular Cloning and Sequencing of Hemoglobin-Beta Gene of Channel Catfish, Ictalurus Punctatus Rafinesque

    : Hemoglobin-y gene of channel catfish , lctalurus punctatus, was cloned and sequenced . Total RNA from head kidneys was isolated, reverse transcribed and amplified . The sequence of the channel catfish hemoglobin-y gene consists of 600 nucleotides . Analysis of the nucleotide sequence reveals one o...

  1. Hemoglobin levels and new-onset heart failure in the community

    Klip, IJsbrand T.; Postmus, Douwe; Voors, Adriaan A.; Brouwers, Frank P. J.; Gansevoort, Ron T.; Bakker, Stephan J. L.; Hillege, Hans L.; de Boer, Rudolf A.; van der Harst, Pim; van Gilst, Wiek H.; van Veldhuisen, Dirk J.; van der Meer, Peter

    Background In established cardiovascular disease and heart failure (HF), low hemoglobin levels are associated with unfavorable outcome. Whether hemoglobin levels are associated with the development of new-onset HF in the population is unclear. This study sought to investigate the relationship

  2. Effect of laser radiation on physicochemical and functional properties of human hemoglobin in vitro

    Irzhak, LI; Zotova, EA; Mamaeva, SA

    Exposure to laser radiation increases pH and isoelectric point of human hemoglobin solution, improves the acid-base properties, increases affinity for oxygen, and decreases the Bohr effect in comparison with intact hemoglobin. The mechanisms underlying these changes are discussed.

  3. Controlled safety study of a hemoglobin-based oxygen carrier, DCLHb, in acute ischemic stroke

    R. Saxena (Ruchi); A.D. Wijnhoud (Annemarie); H. Carton; W. Hacke (Werner); M. Kaste; R.J. Przybelski; K.N. Stern; P.J. Koudstaal (Peter Jan)

    1999-01-01

    textabstractBACKGROUND AND PURPOSE: Diaspirin cross-linked hemoglobin (DCLHb) is a purified, cell-free human hemoglobin solution. In animal stroke models its use led to a significant reduction in the extent of brain injury. The primary objective of this study was to evaluate the safety of DCLHb in

  4. The interaction of 2,3-diphosphoglycerate with various human hemoglobins

    Bunn, H. Franklin; Briehl, Robin W.

    1970-01-01

    Oxygen equilibria were measured on a number of human hemoglobins, which had been “stripped” of organic phosphates and isolated by column chromatography. In the presence of 2 × 10-4 M 2,3-diphosphoglycerate (2,3-DPG), the P50 of hemoglobins A, A2, S, and C increased about twofold, signifying a substantial and equal decrease in oxygen affinity. Furthermore, hemoglobins Chesapeake and MMilwaukee-1 which have intrinsically high and low oxygen affinities, respectively, also showed a twofold increase in P50 in the presence of 2 × 10-4 M 2,3-DPG. In comparison to these, hemoglobins AIC and F were less reactive with 2,3-DPG while hemoglobin FI showed virtually no reactivity. The N-terminal amino of each β-chain of hemoglobin AIC is linked to a hexose. In hemoglobin FI the N-terminal amino of each γ-chain is acetylated. These results suggest that the N-terminal amino groups of the non-α-chains are involved in the binding of 2,3-DPG to hemoglobin. PMID:5422014

  5. HIV and other predictors of serum folate, serum ferritin, and hemoglobin in pregnancy

    Friis, Henrik; Gomo, E; Kæstel, Pernille

    2001-01-01

    BACKGROUND: Folate and iron status and hemoglobin concentrations are important to maternal and infant health. OBJECTIVE: Our goal was to identify predictors of serum folate, serum ferritin, and hemoglobin. DESIGN: This was a cross-sectional study of 1669 pregnant women (22-35 wk of gestation) in ...

  6. Hemoglobin in samples with leukocytosis can be measured on ABL 700 series blood gas analyzers

    Scharnhorst, V.; Laar, van der P.D.; Vader, H.

    2003-01-01

    To compare lactate, bilirubin and Hemoglobin F concentrations obtained on ABL 700 series blood gas analyzers with those from laboratory methods. Pooled neonatal plasma, cord blood and adult plasma samples were used for comparison of bilirubin, hemoglobin F and lactate concentrations respectively.

  7. Iron bioavailability of maize hemoglobin in a Caco-2 cell culture model

    Maize is an important staple crop in many parts of the world but has low iron bioavailability, in part due to its high phytate content. Hemoglobin is a form of iron that is highly bioavailable and its bioavailability is not inhibited by phytate. We hypothesize that maize hemoglobin is a highly bioav...

  8. Hemoglobin as an important prognostic factor in concurrent chemoradiotherapy for locally advanced carcinoma of the cervix

    Toma, Takashi; Nagai, Yutaka; Moromizato, Hidehiko; Toita, Takafumi; Murayama, Sadayuki; Kanazawa, Koji

    2005-01-01

    The objective of this study was to examine a possible association of hemoglobin with clinical outcome in patients with locally advanced squamous cell carcinoma of the cervix who were treated with concurrent chemoradiotherapy (CCRT). Seventy-five patients with Stage IB to IVA disease who were treated with CCRT were reviewed retrospectively. The mean age was 49.8 years. In the treatment, standard radiotherapy was performed accompanied by concomitant chemotherapy using cisplatin. Pre-treatment hemoglobin was defined as the earliest hemoglobin level prior to the initiation of treatment. Weekly nadir hemoglobin levels throughout treatment were averaged and used as average weekly nadir hemoglobin during treatment (AWNHg). The mean follow-up time was 28.6 months. The mean pre-treatment hemoglobin of 11.6 g/dL was significantly reduced to the mean AWNHg of 9.9 g/dL. The levels of pre-treatment hemoglobin and AWNHg were significantly associated with tumor response to treatment. The 5-year cumulative disease-free survival and overall survival rates for all 75 patients were 67.8% and 75.3%, respectively. Multivariate statistical analysis revealed that AWNHg (≥9.0 versus <9.0 g/dL) was an independent prognostic factor for overall survival (p=0.038), but pre-treatment hemoglobin was not a significant factor. AWNHg was one of the most powerful independent predictors of overall survival in patients undergoing CCRT for locally advanced squamous cell carcinoma of the cervix. (author)

  9. Using the Cascade Model to Improve Antenatal Screening for the Hemoglobin Disorders

    Gould, Dinah; Papadopoulos, Irena; Kelly, Daniel

    2012-01-01

    Introduction: The inherited hemoglobin disorders constitute a major public health problem. Facilitators (experienced hemoglobin counselors) were trained to deliver knowledge and skills to "frontline" practitioners to enable them to support parents during antenatal screening via a cascade (train-the-trainer) model. Objectives of…

  10. Aspartic protease activities of schistosomes cleave mammalian hemoglobins in a host-specific manner

    Jeffrey W Koehler

    2007-02-01

    Full Text Available We examined the efficiency of digestion of hemoglobin from four mammalian species, human, cow, sheep, and horse by acidic extracts of mixed sex adults of Schistosoma japonicum and S. mansoni. Activity ascribable to aspartic protease(s from S. japonicum and S. mansoni cleaved human hemoglobin. In addition, aspartic protease activities from S. japonicum cleaved hemoglobin from bovine, sheep, and horse blood more efficiently than did the activity from extracts of S. mansoni. These findings support the hypothesis that substrate specificity of hemoglobin-degrading proteases employed by blood feeding helminth parasites influences parasite host species range; differences in amino acid sequences in key sites of the parasite proteases interact less or more efficiently with the hemoglobins of permissive or non-permissive hosts.

  11. Megalin and cubilin are endocytic receptors involved in renal clearance of hemoglobin

    Gburek, Jakub; Verroust, Pierre J; Willnow, Thomas E

    2002-01-01

    -Sepharose affinity chromatography of solubilized renal brush-border membranes. Apparent dissociation constants of 1.7 microM for megalin and 4.1 microM for cubilin were determined by surface plasmon resonance analysis. The binding was calcium dependent in both cases. Uptake of fluorescence-labeled hemoglobin by BN......The kidney is the main site of hemoglobin clearance and degradation in conditions of severe hemolysis. Herein it is reported that megalin and cubilin, two epithelial endocytic receptors, mediate the uptake of hemoglobin in renal proximal tubules. Both receptors were purified by use of hemoglobin...... not affect the uptake. By use of immunohistochemistry, it was demonstrated that uptake of hemoglobin in proximal tubules of rat, mouse, and dog kidneys occurs under physiologic conditions. Studies on normal and megalin knockout mouse kidney sections showed that megalin is responsible for physiologic...

  12. γ irradiation of aqueous solutions of human hemoglobin in atmospheres of air and argon

    Puchala, M.; Szweda-Lewandowska, Z.; Leyko, W.

    1979-01-01

    In this study, the degrees of destruction of hemoglobin irradiated in atmospheres of air and argon were compared. Hemoglobin preparations were irradiated in the forms: oxyhemoglobin (HbO 2 ) deoxyhemoglobin (Hb 2+ ) and methemoglobin (MetHb) applying doses of 0.5 to 5 Mrad. The degree of hemoglobin destruction was estimate on the basis of changes in the values of the absorption coefficient at the Soret band, the absorption ratio A 505 /A 563 determined after conversion of irradiated preparations into MetHb, absorption coefficinets for pyridine hemochromogen obtained from irradiated preparations, and changes in parameters characterizing the hemoglobin oxygenation reaction (log p/sub 1/2/O 2 and the Hill n coefficient). The calculated oxygen enhancement ratios S were generally higher than 1 for the parameters estimated. This indicates that the presence of oxygen during irradiation enhances hemoglobin destruction

  13. Is a blood sample for hemoglobins in the transfusional range reliable?

    López, A; Gómez, L; Petinal, G; Adán, N; Alvarado, S; Carballo, N

    2018-02-27

    To evaluate the correlation and agreement in our unit and population of hemoglobin in gasometry versus hematology analyzer, to evaluate errors in transfusion or lack thereof. strong association between Point-of-care (POC) and hematimetry, with P<.001, with a coefficient of determination r 2 of 0.56, an intraclass correlation coefficient of 0.63 and a Lin's concordance correlation coefficient of 0.65. For hemoglobins less than 7g/dL, a success rate of 29.41% was obtained. Low-moderate agreement of POC hemoglobin with standard haemothymetry. High probability of errors in the indication of transfusion based on gasometer hemoglobins, especially in low hemoglobins. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. A new polyethyleneglycol-derivatized hemoglobin derivative with decreased oxygen affinity and limited toxicity.

    Zolog, Oana; Mot, Augustin; Deac, Florina; Roman, Alina; Fischer-Fodor, Eva; Silaghi-Dumitrescu, Radu

    2011-01-01

    A new protocol is described for derivatization of hemoglobin with polyethyleneglycol (PEG) via reaction of the unmodified native hemoglobin with an activated amine-reacting polyethylene glycol derivative which, unlike protocols previously described, leads to formation of a peptide bond between hemoglobin and PEG. Dioxygen binding and peroxide reactivities of the derivatized hemoglobin are examined, and found to be within reasonable limits, with the particular observation that, unlike with a few other derivatization protocols, the dioxygen affinity is slightly lower than that of native Hb. In cell culture tests (human umbilical vein epithelial cells, HUVEC), the derivatization protocol induces no toxic effect. These results show promise towards applicability for production of hemoglobin-based blood substitutes.

  15. Action of carbon monoxide on the affinity of hemoglobin for oxygen

    Vanuxem, D.; Weiller, P.J.; Guillot, C.; Grimaud, C.

    1982-01-01

    The authors have studied the action of carbon monoxide on the affinity of hemoglobin for oxygen by measuring P50 in whole blood and in stripped hemoglobin before and after exposition of blood samples from heavy smokers and polycythemic patients with high levels of HbCO to hyperbaric oxygen (2.2 ata). The concentration of 2,3-diphosphoglycerate was normal although P50 was significantly lowered, not only in whole blood but also in stripped hemoglobin. Hyperbaric oxygen normalized P50 by removing CO radicals from stripped hemoglobin. This may indicate that CO radicals exert a direct action on the hemoglobin molecule, at least at the HbCO levels studied in this work.

  16. How Students Learn: Ways of Thinking about "Good Learning" in HE. EDNER (Formative Evaluation of the Distributed National Electronic Resource) Project. Issues Paper.

    Manchester Metropolitan Univ. (England).

    This issues paper, one of a series of eight, is intended to distill formative evaluation questions on topics that are central to the development of the higher and further education information environment in the United Kingdom. The topic of this first issues paper is a conceptual framework that can help members of a project (information resource)…

  17. 大學圖書館電子資源之需求分析與行銷策略之研究 A Study of Demands Analysis and Marketing Strategy of Electronic Resources in University Library

    Huang-Yu Liu

    2008-03-01

    Full Text Available 電子資源的出現,使得知識載體有了新的突破,提高了使用者的便利性與即時性。對於圖書館而言,如何使電子資源的使用效益達到最高,必須思考一套有效的行銷策略。電子資源行銷概念應以讀者為導向,尊重讀者的資訊需求,並利用各種宣傳技巧,行銷電子資源,使圖書館能提供更完善的服務。本研究之目的旨在探討讀者的使用需求及電子資源的推廣策略,以獲致最有效益的行銷方式。研究對象以開南大學日間部四學院(商學院、運輸觀光學院、資訊學院、人文社會學院)學生為樣本,佐以缺口分析模型為分析架構,藉以找出個案中讀者/學生對於電子資源使用的真實需求,並進而歸納出提供服務的大學圖書館在其推廣或行銷服務上可有的因應策略。The emergence of electronic resources has made new breakthrough in knowledge carriers because of their ease of use, instant availability, and the characteristic of no time and space constraints. For public libraries to achieve maximum efficiency in its electronic resources, it is necessary to seek the most effective marketing strategies. Therefore, the marketing concept of the electronic resources should be reader oriented, such as respecting and understanding library user’s information needs. Libraries also need to utilize various media and techniques to market the electronic resources, so that more comprehensive services and experiences can be provided to readers. The purpose of this study is to investigate library user’s needs and promotion strategies of electronic resources in order to identify the most effective ways of marketing. This study focuses on the students of the four colleges (College of Business, College of Tourism, College of Information, and College of Humanities and Social Science in Kainan University as subjects in the survey questionnaire. It uses the Gap Analysis

  18. Simultaneous estimation of transcutaneous bilirubin, hemoglobin, and melanin based on diffuse reflectance spectroscopy

    Nishidate, Izumi; Abdul, Wares MD.; Ohtsu, Mizuki; Nakano, Kazuya; Haneishi, Hideaki

    2018-02-01

    We propose a method to estimate transcutaneous bilirubin, hemoglobin, and melanin based on the diffuse reflectance spectroscopy. In the proposed method, the Monte Carlo simulation-based multiple regression analysis for an absorbance spectrum in the visible wavelength region (460-590 nm) is used to specify the concentrations of bilirubin (Cbil), oxygenated hemoglobin (Coh), deoxygenated hemoglobin (Cdh), and melanin (Cm). Using the absorbance spectrum calculated from the measured diffuse reflectance spectrum as a response variable and the extinction coefficients of bilirubin, oxygenated hemoglobin, deoxygenated hemoglobin, and melanin, as predictor variables, multiple regression analysis provides regression coefficients. Concentrations of bilirubin, oxygenated hemoglobin, deoxygenated hemoglobin, and melanin, are then determined from the regression coefficients using conversion vectors that are numerically deduced in advance by the Monte Carlo simulations for light transport in skin. Total hemoglobin concentration (Cth) and tissue oxygen saturation (StO2) are simply calculated from the oxygenated hemoglobin and deoxygenated hemoglobin. In vivo animal experiments with bile duct ligation in rats demonstrated that the estimated Cbil is increased after ligation of bile duct and reaches to around 20 mg/dl at 72 h after the onset of the ligation, which corresponds to the reference value of Cbil measured by a commercially available transcutaneous bilirubin meter. We also performed in vivo experiments with rats while varying the fraction of inspired oxygen (FiO2). Coh and Cdh decreased and increased, respectively, as FiO2 decreased. Consequently, StO2 was dramatically decreased. The results in this study indicate potential of the method for simultaneous evaluation of multiple chromophores in skin tissue.

  19. Hot atom labeling of myoglobin and hemoglobin and biophysical studies of oxygen and CO binding to carp hemoglobin

    Astatke, M.

    1992-01-01

    Human Hb, the monomeric Hb of Glycera dibranchiata and horse Mb were modified by replacement of the protoheme with 2,4-dibromodeuteroheme. Following neutron capture by 79 Br and 81 Br, the locations of radioactive Br were determined. Although human Hb had approximately four times the mass and volume of the other proteins, about 9% of the activated Br was inserted into each of the three globins. These results suggest that the insertion is short-range (within 15 angstrom) and that this method could be used to label target sites in various proteins and other biological structures. Carp Hb's containing proto-, meso-, deutero- and dibromoheme were prepared. Kinetic and thermodynamic parameters for oxygen and CO binding were determined at Ph 6 (+IHP) (T-state, low-affinity protein) and Ph 9 (R-state, high-affinity protein). Parameters for the binding of oxygen and CO were related to the properties of the four hemes to estimate the inductive and steric factors in the ligation process. The results suggest that the steric factors are more important for the T-state than for the R-state. The T-state carp Hbs were very readily oxidized. Two new procedures were developed for the rapid determination of oxygen equilibrium isotherms for the T-state carp Hbs. The kinetic and thermodynamic parameters for ligation of oxygen and CO with the isolated carp α-chains were determined. Carp α-chains are the only hemoglobin chains isolated to date that can be classified as T-state. The secondary thermodynamic parameter (δH degrees) was found to be essential for classifying hemoglobins as T- or R-state

  20. Diabetes epidemic in the Asia Pacific region: has hemoglobin A1C finally earned its place as a diagnostic tool?

    Alexandra Bagley

    2014-02-01

    Full Text Available Two-third of the world's population lives in the Asia Pacific region where prevalence of diabetes has reached epidemic proportion. With China and India being the most populous nations on the globe, it is believed that over 150 million diabetes reside in the region with more than 95% being of type 2 diabetes mellitus (T2DM. Furthermore, other Pacific islands in the region have high rates of T2DM including Tonga, Fiji, French Polynesia, and Nauru. The latter has the highest prevalence of T2DM per population in the world. Over the past two decades, in Australia and New Zealand, the prevalence of T2DM has more than doubled, mainly amongst the Aboriginal and Torres Strait Islander and Maori peoples respectively. With the increasing prevalence of diabetes in the Asia Pacific region coupled with the limited number of resources, use of a reliable and effective mode of diagnosis for T2DM is warranted. Yet to date, only New Zealand has adopted the American Diabetes Association recommendation of using hemoglobin A1C in the diagnosis of the disease. The aim of this review is to discuss the clinical usefulness of hemoglobin A1C and highlight its diagnostic role in the Asia Pacific region where T2DM is increasingly encountered.