WorldWideScience

Sample records for hematocrit detection methods

  1. Two different hematocrit detection methods: Different methods, different results?

    Directory of Open Access Journals (Sweden)

    Schuepbach Reto A

    2010-03-01

    Full Text Available Abstract Background Less is known about the influence of hematocrit detection methodology on transfusion triggers. Therefore, the aim of the present study was to compare two different hematocrit-assessing methods. In a total of 50 critically ill patients hematocrit was analyzed using (1 blood gas analyzer (ABLflex 800 and (2 the central laboratory method (ADVIA® 2120 and compared. Findings Bland-Altman analysis for repeated measurements showed a good correlation with a bias of +1.39% and 2 SD of ± 3.12%. The 24%-hematocrit-group showed a correlation of r2 = 0.87. With a kappa of 0.56, 22.7% of the cases would have been transfused differently. In the-28%-hematocrit group with a similar correlation (r2 = 0.8 and a kappa of 0.58, 21% of the cases would have been transfused differently. Conclusions Despite a good agreement between the two methods used to determine hematocrit in clinical routine, the calculated difference of 1.4% might substantially influence transfusion triggers depending on the employed method.

  2. PROFILE OF HEMATOCRIT LEVEL CAPTURED BY DIGITAL HEMATOCRIT TEST

    Directory of Open Access Journals (Sweden)

    Prihartini Widiyanti

    2015-09-01

    Full Text Available The dengue fever is a disease caused by Dengue virus which is transmitted via Aedes aegypti and Aedes albopictus vector. This Dengue Haemorrhagic Fever (DHF case in Indonesia tend to rise from year to year caused by delayed detection and inadequate handling. The laboratory parameter of hematocrite had regularly been performed using invasive method by taking the blood from the patient. This method is still not been able to monitor patients with DHF by repetitive and accurate measurament. This research project aims is to perform a digital hematocrit test (DHT with non-invasive accurate sensors. Digital Hematocrit Test (DHT is needed to presenting fast, exact, economical and accurate detection methods of hematocrit level. Measureable magnitude by the instrumentation is non-absorb intensity electromagnetic waves 560 nm emitted by transmitter captured by receiver. Signal captured by the receiver then converted into electrical signal. The electrical signal from receiver was the levels of hemoglobin. Levels of hemoglobin then converted to hematocrit. Hematokrit is three times the level of hemoglobin. Technology of hematocrit monitoring is aimed to control DHF patient clinical symptoms continuously and acquisitively.

  3. PROFILE OF HEMATOCRIT LEVEL CAPTURED BY DIGITAL HEMATOCRIT TEST

    OpenAIRE

    Widiyanti, Prihartini; Sardjono, Tri Arif

    2015-01-01

    The dengue fever is a disease caused by Dengue virus which is transmitted via Aedes aegypti and Aedes albopictus vector. This Dengue Haemorrhagic Fever (DHF) case in Indonesia tend to rise from year to year caused by delayed detection and inadequate handling. The laboratory parameter of hematocrite had regularly been performed using invasive method by taking the blood from the patient. This method is still not been able to monitor patients with DHF by repetitive and accurate measurament. This...

  4. Histogram analysis for smartphone-based rapid hematocrit determination

    Science.gov (United States)

    Jalal, Uddin M.; Kim, Sang C.; Shim, Joon S.

    2017-01-01

    A novel and rapid analysis technique using histogram has been proposed for the colorimetric quantification of blood hematocrits. A smartphone-based “Histogram” app for the detection of hematocrits has been developed integrating the smartphone embedded camera with a microfluidic chip via a custom-made optical platform. The developed histogram analysis shows its effectiveness in the automatic detection of sample channel including auto-calibration and can analyze the single-channel as well as multi-channel images. Furthermore, the analyzing method is advantageous to the quantification of blood-hematocrit both in the equal and varying optical conditions. The rapid determination of blood hematocrits carries enormous information regarding physiological disorders, and the use of such reproducible, cost-effective, and standard techniques may effectively help with the diagnosis and prevention of a number of human diseases. PMID:28717569

  5. Fall in hematocrit per 1000 parasites cleared from peripheral blood: a simple method for estimating drug-related fall in hematocrit after treatment of malaria infections.

    Science.gov (United States)

    Gbotosho, Grace Olusola; Okuboyejo, Titilope; Happi, Christian Tientcha; Sowunmi, Akintunde

    2014-01-01

    A simple method to estimate antimalarial drug-related fall in hematocrit (FIH) after treatment of Plasmodium falciparum infections in the field is described. The method involves numeric estimation of the relative difference in hematocrit at baseline (pretreatment) and the first 1 or 2 days after treatment begun as numerator and the corresponding relative difference in parasitemia as the denominator, and expressing it per 1000 parasites cleared from peripheral blood. Using the method showed that FIH/1000 parasites cleared from peripheral blood (cpb) at 24 or 48 hours were similar in artemether-lumefantrine and artesunate-amodiaquine-treated children (0.09; 95% confidence interval, 0.052-0.138 vs 0.10; 95% confidence interval, 0.069-0.139%; P = 0.75) FIH/1000 parasites cpb in patients with higher parasitemias were significantly (P 1000 parasites cpb were similar in anemic and nonanemic children. Estimation of FIH/1000 parasites cpb is simple, allows estimation of relatively conserved hematocrit during treatment, and can be used in both observational studies and clinical trials involving antimalarial drugs.

  6. Hematocrit as a simple method to predict and manage ovarian hyperstimulation syndrome in assisted reproduction

    Directory of Open Access Journals (Sweden)

    Taswin Kaur

    2015-01-01

    Full Text Available Aim: The aim was to analyze the hematocrit levels in cases of ovarian hyperstimulation syndrome (OHSS, syndrome occurring during in-vitro fertilization (IVF, and study its role as a prognostic indicator. Subjects and Methods: Two years data of 66 women at high risk for developing OHSS was analyzed. Twenty-seven women who developed OHSS were further analyzed based on their hematocrit levels on the day of oocyte pick-up (OPU and the day of embryo transfer (ET to see if there was a prognostic trend. Results: Of the total 225 IVF cases, 66 were deemed high risk for developing OHSS. Twenty-seven of these developed OHSS (40.9%. Of these 27, 21 (77.8% had a hematocrit >35% on the day of OPU. The mean hematocrit in women developing OHSS on the day of OPU was 37.39% (standard deviation [SD] 2.66 as against 35.97% (2.80 in those not developing OHSS. This difference was statistically significant (P = 0.043. On the day of ET, 23/27 (85.8% who developed OHSS had a hematocrit of >35%. The mean hematocrit was 39.29% (SD 3.85 in those who developed OHSS as against 34.7% (2.88 in those who did not. This difference (4.85 was statistically significant (P 35%. Those who required cancellation of ET had a hematocrit of >35% on the day of ET or showed a significant increase of 3% from OPU to ET.

  7. Evaluation of the i-STAT point-of-care capillary whole blood hematocrit and hemoglobin: Comparison to the Siemens RAPIDLab 1200, Sysmex XE5000, and manual spun hematocrit.

    Science.gov (United States)

    Rudolf, Joseph; Douglass, Joseph; Baron, Jason; Lewandrowski, Kent

    2015-06-15

    Conductivity based point-of-care hematocrit with calculated hemoglobin devices serves an important role in clinical scenarios where time sensitive transfusion decisions are necessary. However, questions about the appropriateness of conductivity based assays in certain patient populations (patients on cardiopulmonary bypass and those receiving high volumes of intravenous fluids or autologous blood transfusions) have been raised. The clinical suitability of POC devices for these applications necessitates that they be accurate and that the results are interchangeable with central laboratory methods. We performed hematocrit and hemoglobin analysis on 225 clinical samples using the i-STAT instrument, a standard reference method for hematocrit (manual spun) and other common methods on both cardiopulmonary bypass and non-cardiopulmonary bypass patients. The i-STAT hematocrit and hemoglobin showed close agreement to comparison methods with minimal bias. Median test results were not clinically or statistically different between those measured on the i-STAT and those measured using the manual spun hematocrit reference method (p=0.4085, Wilcoxon signed rank test) or the Sysmex photometric hemoglobin method (p=0.2728, Wilcoxon signed rank test). The results on the i-STAT were statistically different from those obtained on the Sysmex for hematocrit (phemoglobin (phematocrit and hemoglobin performs well when compared to the hematocrit reference method and other common methods for both hematocrit and hemoglobin. Some differences between non-reference methods may be observed, but these were not considered clinically significant. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. The effects of erythrocyte deformability upon hematocrit assessed by the conductance method

    International Nuclear Information System (INIS)

    Hayashi, Yoshihito; Katsumoto, Yoichi; Oshige, Ikuya; Omori, Shinji; Yasuda, Akio; Asami, Koji

    2009-01-01

    A comparative study of centrifugation and conductance methods for the estimation of cell volume fraction (φ) was performed to examine whether the strong forces exerted upon erythrocytes during centrifugation affect their volume, and the results are discussed in terms of erythrocyte deformability. Rabbit erythrocytes of four shapes (spherocytes, echinocytes, stomatocyte-like enlarged erythrocytes and discocytes) were prepared by controlling the pH of the suspending media. The packed cell volumes of the suspensions were measured by standard hematocrit determination methods using centrifugation in capillary tubes. Simultaneously, the same suspensions and their supernatants were used in dielectric spectroscopy measurements, and the low-frequency limits of their conductivities were used for the numerical estimation of φ. The hematocrit values of spherocytes and echinocytes were markedly less than the volume fractions obtained by the conductance method. Namely, the centrifugation reduced the cell volume. For enlarged erythrocytes and discocytes, however, the reduction of cell volume was not observed. These findings showed that φ obtained by the centrifugation method can be greatly affected by the deformability of the cells, but the level of the effect depends on the cell types. Consequently, φ obtained by the centrifugation method should be carefully interpreted.

  9. The effects of erythrocyte deformability upon hematocrit assessed by the conductance method

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Yoshihito; Katsumoto, Yoichi; Oshige, Ikuya; Omori, Shinji; Yasuda, Akio [Life Science Laboratory, Advanced Materials Laboratories, Sony Corporation, Sony Bioinformatics Center, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo 113-8510 (Japan); Asami, Koji [Laboratory of Molecular Aggregation Analysis, Division of Multidisciplinary Chemistry, Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan)], E-mail: Yoshihito.Hayashi@jp.sony.com

    2009-04-21

    A comparative study of centrifugation and conductance methods for the estimation of cell volume fraction ({phi}) was performed to examine whether the strong forces exerted upon erythrocytes during centrifugation affect their volume, and the results are discussed in terms of erythrocyte deformability. Rabbit erythrocytes of four shapes (spherocytes, echinocytes, stomatocyte-like enlarged erythrocytes and discocytes) were prepared by controlling the pH of the suspending media. The packed cell volumes of the suspensions were measured by standard hematocrit determination methods using centrifugation in capillary tubes. Simultaneously, the same suspensions and their supernatants were used in dielectric spectroscopy measurements, and the low-frequency limits of their conductivities were used for the numerical estimation of {phi}. The hematocrit values of spherocytes and echinocytes were markedly less than the volume fractions obtained by the conductance method. Namely, the centrifugation reduced the cell volume. For enlarged erythrocytes and discocytes, however, the reduction of cell volume was not observed. These findings showed that {phi} obtained by the centrifugation method can be greatly affected by the deformability of the cells, but the level of the effect depends on the cell types. Consequently, {phi} obtained by the centrifugation method should be carefully interpreted.

  10. Assessment of pack injection cells and the relationship between hematocrit of pack cells and the increase in hematocrit in patients with thalassemia

    OpenAIRE

    Fekri K; Kasiri K; Jalil T; Ganji F

    2017-01-01

    Background and aims: The amount of injected blood in patients with thalassemia is of particular importance and the blood amount is calculated based on the exact volume of pack cell as well as their hematocrit. The aim of this study was to evaluate pack cells and the factors affecting on the amount of their hematocrit and their association with increase in hematocrit after blood injection. Methods: This is descriptive-analytical study. Characteristics including age, size, type of anticoagu...

  11. Effect of hemolysis and free hemoglobin on optical hematocrit measurements in the extracorporeal circulation.

    Science.gov (United States)

    Paluszkiewicz, Aleksandra; Kellner, Josef; Elshehabi, Morad; Schneditz, Daniel

    2008-01-01

    Clinically significant hemolysis is a rare but serious problem in dialysis. Because hemolysis affects red blood cell count and optical density of plasma it has been speculated whether techniques used for online blood volume monitoring would be useful to detect hemolysis. In this study the influence of free hemoglobin on hematocrit and relative blood volume changes measured by optical means (CritLine, HemaMetrics, Kaysville, UT) were examined using an in vitro model with bovine blood. Free hemoglobin solutions were added in steps to circulating whole blood at baseline hematocrits covering a range from 30% to 60% and at blood flows of approximately 200 and 400 ml/min. The free hemoglobin concentration reached was in the range of 2 to 3 g/dl. The presence of free hemoglobin led to a relative increase in hematocrit in the range of 0.3% per 0.1 g of free hemoglobin per dl (+3% dl/g). As an increase in hematocrit is interpreted as a decrease in blood volume, this change referred to an apparent decrease in relative blood volume in the same order of magnitude (-3% dl/g). Effects were more pronounced at low baseline hematocrit. Thus, although optical hematocrit readings are affected by the presence of free hemoglobin the changes at levels associated with clinical symptoms appear to be too small to be accurately detected in the in vivo situation where the hematocrit and the resulting optical signal is affected by various physiological processes and therefore much noisier.

  12. Hematocrit Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/hematocrittest.html Hematocrit Test To use the sharing features on this page, please enable JavaScript. What is a Hematocrit Test? A hematocrit test is a type of blood ...

  13. 21 CFR 864.6400 - Hematocrit measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematocrit measuring device. 864.6400 Section 864.6400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6400 Hematocrit measuring...

  14. Point of care hematocrit and hemoglobin in cardiac surgery: a review.

    Science.gov (United States)

    Myers, Gerard J; Browne, Joe

    2007-05-01

    The use of point-of-care blood gas analyzers in cardiac surgery has been on the increase over the past decade. The availability of these analyzers in the operating room and post-operative intensive care units eliminates the time delays to transport samples to the main laboratory and reduces the amount of blood sampled to measure such parameters as electrolytes, blood gases, lactates, glucose and hemoglobin/hematocrit. Point-of-care analyzers also lead to faster and more reliable clinical decisions while the patient is still on the heart lung machine. Point-of-care devices were designed to provide safe, appropriate and consistent care of those patients in need of rapid acid/base balance and electrolyte management in the clinical setting. As a result, clinicians rely on their values to make decisions regarding ventilation, acid/base management, transfusion and glucose management. Therefore, accuracy and reliability are an absolute must for these bedside analyzers in both the cardiac operating room and the post-op intensive care units. Clinicians have a choice of two types of technology to measure hemoglobin/hematocrit during bypass, which subsequently determines their patient's level of hemodilution, as well as their transfusion threshold. All modern point-of-care blood gas analyzers measure hematocrit using a technology called conductivity, while other similar devices measure hemoglobin using a technology called co-oximetry. The two methods are analyzed and compared in this review. The literature indicates that using conductivity to measure hematocrit during and after cardiac surgery could produce inaccurate results when hematocrits are less than 30%, and, therefore, result in unnecessary homologous red cell transfusions in some patients. These inaccuracies are influenced by several factors that are common and unique to cardiopulmonary bypass, and will also be reviewed here. It appears that the only accurate, consistent and reliable method to determine hemodilution

  15. Evaluation of Hematocrit Influence on Self-Monitoring of Blood Glucose Based on ISO 15197:2013: Comparison of a Novel System With Five Systems With Different Hematocrit Ranges.

    Science.gov (United States)

    Hattemer, Andrew; Wardat, Sami

    2018-03-01

    ISO 15197:2013 recommends testing procedures and acceptance criteria for the evaluation of influence quantities such as hematocrit on measurement results with systems for self-monitoring of blood glucose (SMBG). In this study, hematocrit influence was evaluated for a novel SMBG system (system A) and five other systems with different hematocrit ranges based on ISO 15197:2013. Test procedures were performed with one test strip lot for each system. Each system was tested within the hematocrit range indicated in the manufacturer's labeling (system A: 10-65%, B: 15-65%, C: 20-60%, D: 35-60%, E: 30-60%, F: 30-55%). According to ISO 15197:2013, clause 6.4.2, venous blood samples were used for the evaluation of hematocrit influence. The evaluation was performed for three glucose concentration categories (30-50 mg/dL, 96-144 mg/dL, and 280-420 mg/dL). For each glucose concentration category, at least five different hematocrit levels were investigated. The novel system A and systems B, E, and F complied with the tested lot with the defined criteria and showed ≤10 mg/dL and ≤10% difference between the test sample and the respective control sample with a hematocrit value of 42% ± 2% for BG concentrations 10% difference at glucose concentrations ≥100 mg/dL. Remarkable hematocrit influence within the labeled hematocrit range was obtained in two systems with the tested reagent system lot. Adequate SMBG systems should be carefully chosen by patients and their health care professionals, particularly for patients with increased and decreased hematocrit values.

  16. Optical measurement of isolated canine lung filtration coefficients at normal hematocrits.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Finney, C; Roselli, R J

    1997-12-01

    In this study, lung filtration coefficient (Kfc) values were measured in eight isolated canine lung preparations at normal hematocrit values using three methods: gravimetric, blood-corrected gravimetric, and optical. The lungs were kept in zone 3 conditions and subjected to an average venous pressure increase of 10.24 +/- 0.27 (SE) cmH2O. The resulting Kfc (ml . min-1 . cmH2O-1 . 100 g dry lung wt-1) measured with the gravimetric technique was 0.420 +/- 0.017, which was statistically different from the Kfc measured by the blood-corrected gravimetric method (0.273 +/- 0.018) or the product of the reflection coefficient (sigmaf) and Kfc measured optically (0. 272 +/- 0.018). The optical method involved the use of a Cellco filter cartridge to separate red blood cells from plasma, which allowed measurement of the concentration of the tracer in plasma at normal hematocrits (34 +/- 1.5). The permeability-surface area product was measured using radioactive multiple indicator-dilution methods before, during, and after venous pressure elevations. Results showed that the surface area of the lung did not change significantly during the measurement of Kfc. These studies suggest that sigmafKfc can be measured optically at normal hematocrits, that this measurement is not influenced by blood volume changes that occur during the measurement, and that the optical sigmafKfc agrees with the Kfc obtained via the blood-corrected gravimetric method.

  17. [Noninvasive detection of hematocrit and the mean corpuscular hemoglobin concentration levels by Vis-NIR spectroscopy].

    Science.gov (United States)

    Zhao, Jing; Lin, Ling; Lu, Xiao-Zuo; Li, Gang

    2014-03-01

    Hematocrit (HCT) and mean hemoglobin concentration(MCHC) play a very important role in preventing cardiovascular disease and anemia. A method was developed on the basis of spectroscopy to detect HCT and MCHC non-invasively and accurately. The anatomical study showed that the blood rheology abnormalities and blood viscosity's changes can cause the changes of tongue, so there is a certain correlation between tongue and blood components. Reflectance spectrums from the tongue tips of 240 volunteers were collected, then the tongue pictures were captured and the biochemical analysis results were recorded at the same time. The 240 samples were separated into two parts: calibration sample and test sample. Spectra were then subjected to a partial least squares regression (PLSR) analysis to develop mathematics models for predicting HCT levels. The correlation between the data and prediction of HCT and MCHC yielded calibration samples value of 0.998 and 0.938. HCT and MCHC levels of test samples predicted by this model from Visible-Near infrared spectra provided a coefficient of determination in prediction of 0.979 and 0.883 with an average relative error of prediction of 1.65% and 1.88%, a root mean square error of prediction of 4.066 and 4.139. From the experiment results we can see that the model which was built before can better predict the HCT and MCHC, and the results also showed that spectrometry method may provide a promising approach to the noninvasive measurement of human HCT and MCHC with a combination of PLSR analysis.

  18. Variation in the hematocrit of the rat after gamma irradiation

    International Nuclear Information System (INIS)

    Marble, G.; Breuil, L.; Berthelet, J.

    1966-01-01

    Statistical analysis of hematocrit measurement results has been carried out for twenty batches of rats with a view to studying the variation in the hematocrit as a function of the irradiation dose during the first four days after this irradiation. A significant increase in the hematocrit has been observed on the third day for 750 and 1000 rads and on the fourth day for 1000 rads only. (authors) [fr

  19. Cerebral hematocrit decreases with hemodynamic compromise in carotid artery occlusion: a PET study.

    Science.gov (United States)

    Yamauchi, H; Fukuyama, H; Nagahama, Y; Katsumi, Y; Okazawa, H

    1998-01-01

    This study investigated whether in patients with internal carotid artery occlusion the regional cerebral hematocrit correlates with cerebral hemodynamics or metabolic state and, if so, how the regional cerebral hematocrit changes in the hemodynamically compromised region. We used positron emission tomography to study seven patients with unilateral internal carotid artery occlusion and no cortical infarction in the chronic stage. The distributions of red blood cell and plasma volumes were assessed using oxygen-15-labeled carbon monoxide and copper-62-labeled human serum albumin-dithiosemicarbazone tracers, respectively. The calculated hematocrit value was compared with the hemodynamic and metabolic parameters measured with the oxygen-15 steady-state technique. In the cerebral cortex, the value of the cerebral hematocrit varied but was correlated with the hemodynamic and metabolic status. Stepwise regression analysis revealed that the large vessel hematocrit, the cerebral metabolic rate of oxygen, and the cerebral blood flow or the oxygen extraction fraction accounted for a significant proportion of variance of the cerebral hematocrit. The oxygen extraction fraction and the cerebral metabolic rate of oxygen negatively correlated with the cerebral hematocrit, whereas the cerebral blood flow correlated positively: patients with reduced blood supply relative to metabolic demand (decreased blood flow with increased oxygen extraction fraction) showed low hematocrit values. In carotid artery occlusion in the chronic stage, regional cerebral hematocrit may vary according to cerebral hemodynamics and metabolic status. Regional cerebral hematocrit may decrease with hemodynamic compromise unless oxygen metabolism concomitantly decreases.

  20. Multiple diagnosis based on photoplethysmography: hematocrit, SpO2, pulse, and respiration

    Science.gov (United States)

    Yoon, Gilwon; Lee, Jong Y.; Jeon, Kye Jin; Park, Kun-Kook; Yeo, Hyung S.; Hwang, Hyun T.; Kim, Hong S.; Hwang, In-Duk

    2002-09-01

    Photo-plethysmography measures pulsatile blood flow in real-time and non-invasively. One of widely known applications of PPG is the measurement of saturated oxygen in arterial blood(SpO2). In our work, using several wavelengths more than those used in a pulse oximeter, an algorithm and instrument have been developed to measure hematocrit, saturated oxygen, pulse and respiratory rates simultaneously. To predict hematocrit, a dedicated algorithm is developed based on scattering of RBC and a protocol for detecting outlier signals is used to increase accuracy and reliability. Digital filtering techniques are used to extract respiratory rate signals. Utilization of wavelengths under 1000nm and a multi-wavelength LED array chip and digital-oriented electronics enable us to make a compact device. Our preliminary clinical trials show that the achieved percent errors are +/-8.2% for hematocrit when tested with 594 persons, R2 for SpO2 fitting is 0.99985 when tested with a Bi-Tek pulse oximeter simulator and the SpO2 error for in vivo test is +/-2.5% over the range of 75~100%. The error of pulse rates is less than +/-5%. We obtained a positive predictive value of 96% for respiratory rates in qualitative analysis.

  1. Hematocrit analysis through the use of an inexpensive centrifugal polyester-toner device with finger-to-chip blood loading capability

    International Nuclear Information System (INIS)

    Thompson, Brandon L.; Gilbert, Rachel J.; Mejia, Maximo; Shukla, Nishant; Haverstick, Doris M.; Garner, Gavin T.; Landers, James P.

    2016-01-01

    Hematocrit (HCT) measurements are important clinical diagnostic variables that help physicians diagnose and treat various medical conditions, ailments, and diseases. In this work, we present the HCT Disc, a centrifugal microdevice fabricated by a Print, Cut and Laminate (PCL) method to generate a 12-sample HCT device from materials costing <0.5 USD (polyester and toner or PeT). Following introduction from a drop of blood (finger stick), whole blood metering and cell sedimentation are controlled by centrifugal force, only requiring a CD player motor as external hardware and, ultimately, a cell phone for detection. The sedimented volume from patient blood in the HCT Disc was analyzed using a conventional scanner/custom algorithm for analysis of the image to determine a hematocrit value, and these were compared to values generated in a clinical laboratory, which correlated well. To enhance portability and assure simplicity of the HCT measurement, values from image analysis by a cell phone using a custom application was compared to the scanner. Fifteen samples were analyzed with cell phone image analysis system and were found to be within 4% of the HCT values determined in the clinical lab. We demonstrate the feasibility of the PeT device for HCT measurement, and highlight its uniquely low cost (<0.5 USD), speed (sample-to-answer <8 min), multiplexability (12 samples), low volume whole blood requirement (<3 μL), rotation speeds (<4000 rpm) needed for effective measurement as well as the direct finger-to-chip sample loading capability. - Highlights: • A 12-sample hematocrit device was developed from polyester-toner materials. • The device can analyze a patient's hematocrit within 8 min from 3 μL of blood. • Cell phone image analysis is used to correctly determine clinical hematocrits.

  2. Hematocrit analysis through the use of an inexpensive centrifugal polyester-toner device with finger-to-chip blood loading capability

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Brandon L.; Gilbert, Rachel J. [Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904 (United States); Mejia, Maximo [Department of Mechanical Engineering, Engineer' s Way, University of Virginia, Charlottesville, VA 22904 (United States); Shukla, Nishant [Department of Computer Science, Engineer' s Way, University of Virginia, Charlottesville, VA 22904 (United States); Haverstick, Doris M. [Department of Pathology, University of Virginia Health Science Center, Charlottesville, VA 22908 (United States); Garner, Gavin T. [Department of Mechanical Engineering, Engineer' s Way, University of Virginia, Charlottesville, VA 22904 (United States); Landers, James P., E-mail: landers@virginia.edu [Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904 (United States); Department of Mechanical Engineering, Engineer' s Way, University of Virginia, Charlottesville, VA 22904 (United States); Department of Pathology, University of Virginia Health Science Center, Charlottesville, VA 22908 (United States)

    2016-06-14

    Hematocrit (HCT) measurements are important clinical diagnostic variables that help physicians diagnose and treat various medical conditions, ailments, and diseases. In this work, we present the HCT Disc, a centrifugal microdevice fabricated by a Print, Cut and Laminate (PCL) method to generate a 12-sample HCT device from materials costing <0.5 USD (polyester and toner or PeT). Following introduction from a drop of blood (finger stick), whole blood metering and cell sedimentation are controlled by centrifugal force, only requiring a CD player motor as external hardware and, ultimately, a cell phone for detection. The sedimented volume from patient blood in the HCT Disc was analyzed using a conventional scanner/custom algorithm for analysis of the image to determine a hematocrit value, and these were compared to values generated in a clinical laboratory, which correlated well. To enhance portability and assure simplicity of the HCT measurement, values from image analysis by a cell phone using a custom application was compared to the scanner. Fifteen samples were analyzed with cell phone image analysis system and were found to be within 4% of the HCT values determined in the clinical lab. We demonstrate the feasibility of the PeT device for HCT measurement, and highlight its uniquely low cost (<0.5 USD), speed (sample-to-answer <8 min), multiplexability (12 samples), low volume whole blood requirement (<3 μL), rotation speeds (<4000 rpm) needed for effective measurement as well as the direct finger-to-chip sample loading capability. - Highlights: • A 12-sample hematocrit device was developed from polyester-toner materials. • The device can analyze a patient's hematocrit within 8 min from 3 μL of blood. • Cell phone image analysis is used to correctly determine clinical hematocrits.

  3. Non-invasive prediction of hematocrit levels by portable visible and near-infrared spectrophotometer.

    Science.gov (United States)

    Sakudo, Akikazu; Kato, Yukiko Hakariya; Kuratsune, Hirohiko; Ikuta, Kazuyoshi

    2009-10-01

    After blood donation, in some individuals having polycythemia, dehydration causes anemia. Although the hematocrit (Ht) level is closely related to anemia, the current method of measuring Ht is performed after blood drawing. Furthermore, the monitoring of Ht levels contributes to a healthy life. Therefore, a non-invasive test for Ht is warranted for the safe donation of blood and good quality of life. A non-invasive procedure for the prediction of hematocrit levels was developed on the basis of a chemometric analysis of visible and near-infrared (Vis-NIR) spectra of the thumbs using portable spectrophotometer. Transmittance spectra in the 600- to 1100-nm region from thumbs of Japanese volunteers were subjected to a partial least squares regression (PLSR) analysis and leave-out cross-validation to develop chemometric models for predicting Ht levels. Ht levels of masked samples predicted by this model from Vis-NIR spectra provided a coefficient of determination in prediction of 0.6349 with a standard error of prediction of 3.704% and a detection limit in prediction of 17.14%, indicating that the model is applicable for normal and abnormal value in Ht level. These results suggest portable Vis-NIR spectrophotometer to have potential for the non-invasive measurement of Ht levels with a combination of PLSR analysis.

  4. A Novel, Nondestructive, Dried Blood Spot-Based Hematocrit Prediction Method Using Noncontact Diffuse Reflectance Spectroscopy

    NARCIS (Netherlands)

    Capiau, S.; Wilk, L.S.; Aalders, M.C.G.; Stove, C.P.

    2016-01-01

    Dried blood spot (DBS) sampling is recognized as a valuable alternative sampling strategy both in research and in clinical routine. Although many advantages are associated with DBS sampling, its more widespread use is hampered by several issues, of which the hematocrit effect on DBS-based

  5. Distortion of calculated whole-body hematocrit during lower-body immersion in water.

    Science.gov (United States)

    Knight, D R; Santoro, T; Bondi, K R

    1986-11-01

    We found a difference between the venous hematocrits of immersed and nonimmersed arms during immersion of the lower body in cold water but not during a comparable exposure to warm water. Fourteen healthy men were exposed to three different experimental conditions: arm immersion, body immersion, and control. The men always sat upright while both upper extremities hung vertically at their sides. During arm immersion, one forearm was completely immersed for 30 min in either cold water (28 degrees C, n = 7) or warm water (38 degrees C, n = 7). This cold-warm water protocol was repeated on separate days for exposure to the remaining conditions of body immersion (immersion of 1 forearm and all tissues below the xiphoid process) and control (no immersion). Blood samples were simultaneously drawn from cannulated veins in both antecubital fossae. Hematocrit difference (Hct diff) was measured by subtracting the nonimmersed forearm's hematocrit (Hct dry) from the immersed forearm's hematocrit (Hct wet). Hct diff was approximately zero when the men were exposed to the control condition and body immersion in warm water. In the remaining conditions, Hct wet dropped below Hct dry (P less than 0.01, 3-way analysis of variance). The decrements of Hct diff showed there were differences between venous hematocrits in immersed and nonimmersed regions of the body, indicating that changes of the whole-body hematocrit cannot be calculated from a large-vessel hematocrit soon after immersing the lower body in cold water.

  6. The hematocrit paradox--how does blood doping really work?

    Science.gov (United States)

    Böning, D; Maassen, N; Pries, A

    2011-04-01

    The wide-spread assumption that doping with erythropoietin or blood transfusion is only effective by increasing arterial blood O2 content because of rising hematocrit is not self-evident. "Natural blood dopers" (horses, dogs) increase both hematocrit and circulating blood volume during exercise by releasing stored erythrocytes from the spleen. Improvement of aerobic performance by augmenting hemoglobin concentration may be expected until the optimal hematocrit is reached; above this value maximal cardiac output declines due to the steep increase of blood viscosity. Therefore an enlarged blood oxygen content might only be useful if the normal hematocrit of man during exercise is suboptimal. However, recent studies suggest that cardiac power rises after erythropoietin allowing an unchanged cardiac output in spite of increased viscosity. Other factors underlying improved performance after blood doping might be: augmented diffusion capacity for oxygen in lungs and tissues, increased percentage of young red cells with good functional properties (after erythropoietin), increased buffer capacity, increase of blood volume, vasoconstriction, reduced damage by radicals, mood improvement by cerebral effects of erythropoietin. Also the importance of placebo is unknown since double-blind studies are rare. It is suggested that blood doping has multifactorial effects not restricted to the increase in arterial oxygen content. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Serum alanine aminotransferase levels, hematocrit rate and body weight correlations before and after hemodialysis session

    Directory of Open Access Journals (Sweden)

    Edmundo Pessoa Lopes

    2009-01-01

    Full Text Available PURPOSE: To evaluate alanine aminotransferase levels before and after a hemodialysis session and to correlate these values with the hematocrit rate and weight loss during hemodialysis. PATIENTS AND METHODS: The serum alanine aminotransferase levels, hematocrit rate and body weight were measured and correlated before and after a single hemodialysis session for 146 patients with chronic renal failure. An receiver operating characteristic (ROC curve for the serum alanine aminotransferase levels collected before and after hemodialysis was plotted to identify hepatitis C virus-infected patients. RESULTS: The mean weight loss of the 146 patients during hemodialysis was 5.3% (p < 0.001. The mean alanine aminotransferase levels before and after hemodialysis were 18.8 and 23.9 IU/, respectively, denoting a significant 28.1% increase. An equally significant increase of 16.4% in the hematocrit rate also occurred after hemodialysis. The weight loss was inversely correlated with the rise in both the alanine aminotransferase level (r = 0.3; p < 0.001 and hematocrit rate (r = 0.5; p < 0.001. A direct correlation was found between the rise in alanine aminotransferase levels and the hematocrit during the hemodialysis session (r = 0.4; p < 0.001. Based on the ROC curve, the upper limit of the normal alanine aminotransferase level should be reduced by 40% relative to the upper limit of normal if the blood samples are collected before the hemodialysis session or by 60% if blood samples are collected after the session. CONCLUSION: In the present study, significant elevations in the serum alanine aminotransferase levels and hematocrit rates occurred in parallel to a reduction in body weight after the hemodialysis session. These findings suggest that one of the factors for low alanine aminotransferase levels prior to hemodialysis could be hemodilution in patients with chronic renal failure.

  8. Correction for the Hematocrit Bias in Dried Blood Spot Analysis Using a Nondestructive, Single-Wavelength Reflectance-Based Hematocrit Prediction Method.

    Science.gov (United States)

    Capiau, Sara; Wilk, Leah S; De Kesel, Pieter M M; Aalders, Maurice C G; Stove, Christophe P

    2018-02-06

    The hematocrit (Hct) effect is one of the most important hurdles currently preventing more widespread implementation of quantitative dried blood spot (DBS) analysis in a routine context. Indeed, the Hct may affect both the accuracy of DBS methods as well as the interpretation of DBS-based results. We previously developed a method to determine the Hct of a DBS based on its hemoglobin content using noncontact diffuse reflectance spectroscopy. Despite the ease with which the analysis can be performed (i.e., mere scanning of the DBS) and the good results that were obtained, the method did require a complicated algorithm to derive the total hemoglobin content from the DBS's reflectance spectrum. As the total hemoglobin was calculated as the sum of oxyhemoglobin, methemoglobin, and hemichrome, the three main hemoglobin derivatives formed in DBS upon aging, the reflectance spectrum needed to be unmixed to determine the quantity of each of these derivatives. We now simplified the method by only using the reflectance at a single wavelength, located at a quasi-isosbestic point in the reflectance curve. At this wavelength, assuming 1-to-1 stoichiometry of the aging reaction, the reflectance is insensitive to the hemoglobin degradation and only scales with the total amount of hemoglobin and, hence, the Hct. This simplified method was successfully validated. At each quality control level as well as at the limits of quantitation (i.e., 0.20 and 0.67) bias, intra- and interday imprecision were within 10%. Method reproducibility was excellent based on incurred sample reanalysis and surpassed the reproducibility of the original method. Furthermore, the influence of the volume spotted, the measurement location within the spot, as well as storage time and temperature were evaluated, showing no relevant impact of these parameters. Application to 233 patient samples revealed a good correlation between the Hct determined on whole blood and the predicted Hct determined on venous DBS. The

  9. Reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period: data from a multihospital health care system.

    Science.gov (United States)

    Jopling, Jeffery; Henry, Erick; Wiedmeier, Susan E; Christensen, Robert D

    2009-02-01

    "Reference ranges" are developed when it is impossible or inappropriate to establish "normal ranges" by drawing blood on healthy normal volunteers. Reference ranges for the hematocrit and the blood hemoglobin concentration of newborn infants have previously been reported from relatively small sample sizes by using measurement methods that now are considered outmoded. We sought to develop reference ranges for hematocrit and hemoglobin during the neonatal period (28 days) by using very large sample sizes and modern hematology analyzers, accounting for gestational and postnatal age and gender. Data were assembled from a multihospital health care system after exclusion of patients with a high likelihood of an abnormal value and those who were receiving blood transfusions. During the interval from 22 to 40 weeks' gestation, the hematocrit and blood hemoglobin concentration increased approximately linearly. For every week advance in gestational age, the hematocrit increased by 0.64% and the hemoglobin concentration increased by 0.21 g/dL. No difference was seen on the basis of gender. During the 4-hour interval after birth, hematocrit/hemoglobin values of late preterm and term neonates (35-42 weeks' gestation) increased by 3.6% +/- 0.5% (mean +/- SD), those of neonates of 29 to 34 weeks' gestation remained unchanged, and those of hematocrit/hemoglobin occurred. The figures presented herein describe reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period, accounting for gestational and postnatal age.

  10. Evaluation of newly developed veterinary portable blood glucose meter with hematocrit correction in dogs and cats.

    Science.gov (United States)

    Mori, Akihiro; Oda, Hitomi; Onozawa, Eri; Shono, Saori; Sako, Toshinori

    2017-10-07

    This study evaluated the accuracy of a newly developed veterinary portable blood glucose meter (PBGM) with hematocrit correction in dogs and cats. Sixty-one dogs and 31 cats were used for the current study. Blood samples were obtained from each dog and cat one to six times. Acceptable results were obtained in error grid analysis between PBGM and reference method values (glucose oxidation methods) in both dogs and cats. Bland-Altman plot analysis revealed a mean difference between the PBGM value and reference method value of -1.975 mg/dl (bias) in dogs and 1.339 mg/dl (bias) in cats. Hematocrit values did not affect the results of the veterinary PBGM. Therefore, this veterinary PBGM is clinically useful in dogs and cats.

  11. Preoperative Hematocrit Concentration and the Risk of Stroke in Patients Undergoing Isolated Coronary-Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Khaled M. Musallam

    2013-01-01

    Full Text Available Background. Identification and management of risk factors for stroke following isolated coronary artery bypass grafting (CABG could potentially lower the risk of such serious morbidity. Methods. We retrieved data for 30-day stroke incidence and perioperative variables for patients undergoing isolated CABG and used multivariate logistic regression to assess the adjusted effect of preoperative hematocrit concentration on stroke incidence. Results. In 2,313 patients (mean age 65.9 years, 73.6% men, 43 (1.9%, 95% CI: 1.4–2.5 developed stroke within 30 days following CABG (74.4% within 6 days. After adjustment for a priori defined potential confounders, each 1% drop in preoperative hematocrit concentration was associated with 1.07 (95% CI: 1.01–1.13 increased odds for stroke (men, OR: 1.08, 95% CI: 1.01–1.16; women, OR: 1.02, 95% CI: 0.91–1.16. The predicted probability of stroke for descending preoperative hematocrit concentration exceeded 2% for values <37% (<37% for men (adjusted OR: 2.39, 95% CI: 1.08–5.26 and <38% for women (adjusted OR: 2.52, 95% CI: 0.53–11.98, with a steeper probability increase noted in men. The association between lower preoperative hematocrit concentration and stroke was evident irrespective of intraoperative transfusion use. Conclusion. Screening and management of patients with low preoperative hematocrit concentration may alter postoperative stroke risk in patients undergoing isolated CABG.

  12. Hematocrit is associated with carotid atherosclerosis in men but not in women.

    Science.gov (United States)

    Irace, Concetta; Ciamei, Monica; Crivaro, Andrea; Fiaschi, Elio; Madia, Angela; Cortese, Claudio; Gnasso, Agostino

    2003-06-01

    It is known that blood and plasma viscosities are associated with clinical manifestations of atherosclerosis, though evidence is not conclusive particularly in women. To verify whether hematocrit and blood and plasma viscosities are independently associated with carotid atherosclerosis and whether their measurement can improve the definition of the global coronary heart disease (CHD) risk. Eight hundred and ninety-two participants in a cardiovascular disease prevention campaign were examined with regard to conventional CHD risk factors (age, blood pressure, lipids, glucose, body mass index, waist/hip ratio, cigarette smoking and diabetes), hematocrit and blood and plasma viscosities. According to the degree of carotid atherosclerosis, investigated by echo-Doppler, participants were divided in three groups: those without atherosclerosis, those with a low degree of atherosclerosis and those with a high degree of atherosclerosis. In men, age, blood pressure, intima-media thickness (IMT), hematocrit (47.4+/-3.7%, 47.8+/-3.7%, 48.4+/-3.7%, Pviscosity (4.69+/-0.51 cP, 4.77+/-0.55 cP, 4.82+/-0.51 cP, P=0.05) increased with increasing degree of carotid atherosclerosis. In women, age, blood pressure, total cholesterol and low-density lipoprotein-cholesterol, IMT and plasma viscosity (1.42+/-0.12 cP, 1.44+/-0.11 cP, 1.46+/-0.13 cP, Pviscosity was no longer different in the three groups. In discriminant analysis, hematocrit, among the hemorheological variables investigated, was independently associated with carotid score in men (F=3.66, Pviscosities were significantly associated with carotid score in women. These findings suggest that in men, both hematocrit and blood viscosity are related to carotid atherosclerosis but hematocrit would appear to have an independent effect over and above that mediated by viscosity.

  13. Is Routine Ordering of Both Hemoglobin and Hematocrit Justifiable?

    Science.gov (United States)

    Addison, David J.

    1966-01-01

    In order to assess the value of routine simultaneous hemoglobin and hematocrit determinations, paired determinations in the following groups were studied: (1) 360 consecutive pairs from the hematology laboratory, (2) 95 pairs on general medical patients, (3) 43 pairs on 10 patients with upper gastrointestinal hemorrhage, and (4) 62 pairs on 10 patients with burns. These values were plotted on scatter diagrams. In the 560 pairs only three disparate determinations were found. It is concluded that, in most clinical situations, determination of the hemoglobin or the hematocrit as a screening procedure provides as much useful information as the simultaneous determination of both. PMID:5296947

  14. 21 CFR 864.5600 - Automated hematocrit instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated hematocrit instrument. 864.5600 Section 864.5600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  15. Do blood tests cause anemia in hospitalized patients? The effect of diagnostic phlebotomy on hemoglobin and hematocrit levels.

    Science.gov (United States)

    Thavendiranathan, Paaladinesh; Bagai, Akshay; Ebidia, Albert; Detsky, Allan S; Choudhry, Niteesh K

    2005-06-01

    To determine whether phlebotomy contributes to changes in hemoglobin and hematocrit levels in hospitalized general internal medicine patients. Retrospective cohort study. General internal medicine inpatient service at a tertiary care hospital. All adult patients discharged from the Toronto General Hospital's internal medicine service between January 1 and June 30, 2001. A total of 989 hospitalizations were reviewed and 404 hospitalizations were included in our analysis. Mean (SD) hemoglobin and hematocrit changes during hospitalization were 7.9 (12.6) g/L (Phemoglobin and hematocrit were predicted by the volume of phlebotomy, length of hospital stay, admission hemoglobin/hematocrit value, age, Charlson comorbidity index, and admission intravascular volume status. The volume of phlebotomy remained a strong predictor of drop in hemoglobin and hematocrit after adjusting for other predictors using multivariate analysis (Phemoglobin and hematocrit of 7.0 g/L and 1.9%, respectively. Phlebotomy is highly associated with changes in hemoglobin and hematocrit levels for patients admitted to an internal medicine service and can contribute to anemia. This anemia, in turn, may have significant consequences, especially for patients with cardiorespiratory diseases. Knowing the expected changes in hemoglobin and hematocrit due to diagnostic phlebotomy will help guide when to investigate anemia in hospitalized patients.

  16. Maternal hemoglobin and hematocrit levels during pregnancy and childhood lung function and asthma. The Generation R Study.

    Science.gov (United States)

    Pereira de Jesus, Sabrina M C B; den Dekker, Herman T; de Jongste, Johan C; Reiss, Irwin K; Steegers, Eric A; Jaddoe, Vincent W V; Duijts, Liesbeth

    2018-02-01

    To examine the associations of maternal hemoglobin and hematocrit levels during pregnancy with childhood lung function and asthma, and whether adverse pregnancy outcomes and atopic predisposition modify the associations. In a population-based prospective cohort study among 3672 subjects, we measured maternal hemoglobin and hematocrit levels in early pregnancy, and lung function by spirometry and current asthma by questionnaire at age 10 years. Higher maternal hematocrit levels, both continuously and categorized into clinical cut-offs, were associated with lower forced expiratory flow at 75% of forced vital capacity (FEF 75 ) in children (Z-score (95%CI): -0.04 (-0.07, -0.01), per increase of 1 SDS in hematocrit level; Z-score (95%CI) difference: -0.11 (-0.20, -0.03) compared with normal hematocrit levels, respectively), taking lifestyle and socio-economic factors into account. Adverse pregnancy outcomes and atopic predisposition did not modify the results. No associations of maternal hemoglobin and hematocrit with current asthma were observed. Higher maternal hematocrit levels during pregnancy are associated with lower childhood lung function but not with risk of asthma. Adverse pregnancy outcomes and atopic predisposition do not modify these associations. Underlying mechanisms need to be further studied. © 2017 Wiley Periodicals, Inc.

  17. Substitution of Fingertip Blood for Venous Blood in the Measurement of Hematocrit and Hemoglobin Following Exercise

    Science.gov (United States)

    Fahey, Thomas D.; And Others

    1977-01-01

    Results from comparative testing indicate that fingertip blood is a valid indicator of antecubital venous hematocrit (hct) and hemoglobin (hgb), and that hct ratios determined on the Coulter counter are comparable to those found by the microhematocrit method. (MB)

  18. The effect of hematocrit and hemoglobin on the risk of ischemic heart disease: A Mendelian randomization study.

    Science.gov (United States)

    Zhong, Y; Lin, S L; Schooling, C M

    2016-10-01

    Hematocrit and hemoglobin affect viscosity, and have been considered as risk factors for ischemic heart disease (IHD), although observations are inconsistent; randomized controlled trials targeting hematocrit or hemoglobin have not been definitive. To clarify their role, the risk of IHD was assessed according to genetically determined hematocrit and hemoglobin. We applied single nucleotide polymorphisms (SNPs) strongly determining hematocrit and hemoglobin, from a genome wide association study, to a large case (64,746) control (130,681) study of coronary artery disease, CARDIoGRAMplusC4D, to obtain unconfounded estimates using instrumental variable analysis by combining the Wald estimators for each SNP taking into account any correlation between SNPs using weighted generalized linear regression. Hematocrit was positively associated with IHD, odds ratio (OR) 1.07 per %, 95% confidence interval (CI) 1.03 to 1.11, before and after excluding SNPs from gene regions directly functionally relevant to IHD. However, hematocrit was not associated with IHD (OR 0.99, 0.94 to 1.04) after also excluding SNPs associated with lipids at genome wide significance. Hemoglobin was not associated with IHD (OR 1.06 per g/dL, 0.97 to 1.15) which was similar (OR 1.02, 0.94 to 1.11) after excluding SNPs from gene regions directly functionally relevant to IHD. Hemoglobin was negatively associated with IHD after also excluding SNPs associated with lipids at genome wide significance (OR 0.86, 0.78 to 0.94). In conclusion, hematocrit shares genetic determinants with IHD, but whether the genes contribute to IHD via hematocrit or other mechanisms is not entirely clear. Higher Hemoglobin is unlikely to cause IHD. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Retinal vessel diameters in relation to hematocrit variation during acclimatization of highlanders to sea level altitude

    DEFF Research Database (Denmark)

    Kofoed, Peter Kristian; Sander, Birgit; Zubieta-Calleja, Gustavo

    2009-01-01

    PURPOSE: To examine variations in retinal vessel diameters during acclimatization of native highlanders to normobaric normoxia at sea level. METHODS: Fifteen healthy residents of the greater La Paz region in Bolivia (3600 m above sea level) were examined thrice over a 72-day period, after having...... traveled by airplane to Copenhagen, Denmark, near sea level. RESULTS: In the study subjects, hematocrit decreased from 49.6% (day 2) to 45.9% (P = 0.0066, day 23) and 41.7% (P ... diameters were indistinguishable from baseline after 72 days. No funduscopic signs of retinopathy were observed. Arterial blood pressure remained stable throughout the study. CONCLUSIONS: Although a 16% reduction in hematocrit occurred between days 2 and 72 after arrival at sea level, the only significant...

  20. Maternal hemoglobin and hematocrit levels during pregnancy and childhood lung function and asthma. The Generation R Study

    NARCIS (Netherlands)

    Pereira de Jesus, S.M.C.B. (Sabrina M. C. B.); H.T. den Dekker (Herman); J.C. de Jongste (Johan); I.K.M. Reiss (Irwin); E.A.P. Steegers (Eric); V.W.V. Jaddoe (Vincent); L. Duijts (Liesbeth)

    2018-01-01

    textabstractObjective: To examine the associations of maternal hemoglobin and hematocrit levels during pregnancy with childhood lung function and asthma, and whether adverse pregnancy outcomes and atopic predisposition modify the associations. Methods: In a population-based prospective cohort study

  1. Myth or reality : Hematocrit and hemoglobin differ in trauma

    NARCIS (Netherlands)

    Nijboer, Johanna M. M.; van der Horst, Iwan C. C.; Hendriks, Herman G. D.; ten Duis, Hendrik-Jan; Nijsten, Maarten W. N.

    Background: Estimating blood loss in trauma patients usually involves the determination of hematocrit (Ht) or hemoglobin (Hb). However, in trauma patients, a poorly substantiated habit exists to determine both Ht and Hb in assessing acute blood loss. This suggests that Ht and Hb provide different

  2. Hemoglobin, hematocrit, and changes in cerebral blood flow : The Second Manifestations of ARTerial disease-Magnetic Resonance study

    NARCIS (Netherlands)

    van der Veen, Pieternella H.; Muller, Majon; Vincken, Koen L.; Westerink, Jan; Mali, Willem P. T. M.; van der Graaf, Yolanda; Geerlings, Mirjam I.; Doevendans, PAFM

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease

  3. Evaluation of point-of-care analyzers' ability to reduce bias in conductivity-based hematocrit measurement during cardiopulmonary bypass

    NARCIS (Netherlands)

    Teerenstra, S.; Steinfelder-Visscher, J.; Gunnewiek, J.K.; Weerwind, P.W.

    2014-01-01

    Most point-of-care testing analyzers use the conductivity method to measure hematocrit (hct). During open-heart surgery, blood-conductivity is influenced by shifts in electrolyte and colloid concentrations caused by infusion media used, and this may lead to considerable bias in the hct measurement.

  4. Hematocrit, anemia, and arm preference for blood sample collection ...

    African Journals Online (AJOL)

    Background: Anemia in pregnancy is a common cause of maternal morbidity and mortality in developing countries. Regular review of hematocrit (HCT) and anemia patterns in pregnancy is necessary in our environment. Aim: The aim was to determine the average HCT, prevalence, and pattern of anemia, as well the arm ...

  5. Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood

    Directory of Open Access Journals (Sweden)

    Małgorzata Jędrzejewska-Szczerska

    2014-04-01

    Full Text Available In this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing interferometer. The first step in the research on such sensor is the assessment of its performance under favorable conditions, i.e., using blood samples from healthy volunteers tested in vitro. Such an experiment was conducted using a sensor comprising a superluminescent diode source, an optical spectrum analyzer working as the detection setup and a sensing Fabry-Perot interferometer providing high interference contrast. The response of this sensor was recorded for several samples and compared with the reference laboratory method. The coefficient of determination (R2 for a linear relationship between the results given by both methods was 0.978 and the difference between these results was less than 1%. The presented results suggest that further research into the performance of the sensor is merited.

  6. Critical hematocrit and oxygen partial pressure in the beating heart of pigs.

    Science.gov (United States)

    Hiebl, B; Mrowietz, C; Ploetze, K; Matschke, K; Jung, F

    2010-12-01

    In cardiac surgery the substitution of lost blood volume by plasma substitutes is a common therapeutical approach. None of the currently available blood substitutes has a sufficient oxygen transport capacity. This can limit the functional integrity of the myocardium known as highly oxygen consumptive. The study was aimed to get information about the minimal hematocrit, also known as critical hematocrit (cHct), which guarantees a stable and adequate oxygen partial pressure in the myocardium (pO2). In adult female pigs (n=7) the hematocrit was reduced by isovolemic blood dilution with an intravenous infusion of isotonic 4% gelatine polysuccinate solution, The substituted blood volume ranged between 3000ml and 7780ml (mean: 5254±1672ml). In all animals the pO2 of the myocardium of the beating heart and of the resting skeletal muscle increased until blood dilution resulted in a Hct decrease down to 15%. Further blood dilution resulted in a decrease of the pO2. Only after the Hct was <10% the pO2 was lower than before blood dilution and accompanied by a lethal ischemia of the myocardium. These data indicate a cHct of about 10% in the pig animal model. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Hemoglobin, hematocrit, and changes in cerebral blood flow: the Second Manifestations of ARTerial disease-Magnetic Resonance study.

    Science.gov (United States)

    van der Veen, Pieternella H; Muller, Majon; Vincken, Koen L; Westerink, Jan; Mali, Willem P T M; van der Graaf, Yolanda; Geerlings, Mirjam I

    2015-03-01

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease (mean age 57 ± 10 years) with available data on magnetic resonance angiography to measure parenchymal CBF. Mean (SD) parenchymal CBF at baseline was 52.3 (9.8) mL/min/100 mL and decreased with 1.5 (11.0) mL/min/100 mL after on average 3.9 years of follow-up. Linear regression analyses showed that greater hemoglobin and hematocrit values were associated with lower baseline parenchymal CBF and more decline in parenchymal CBF over time, independent of cardiovascular risk factors, use of antiplatelet drugs, anticoagulants, or diuretics, and brain measures: adjusted mean differences (95% confidence interval [CI]) in decline in parenchymal CBF between patients in the lower and upper quartiles of hemoglobin and hematocrit were -2.48 (95% CI -3.70 to -1.25) and -3.69 (95% CI -5.45 to -1.94) mL/min/100 mL. Higher hemoglobin and hematocrit were associated with lower baseline parenchymal CBF and a greater decline in parenchymal CBF over time, possibly as a result of physiological compensating mechanisms. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. 21 CFR 864.8165 - Calibrator for hemoglobin or hematocrit measurement.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Calibrator for hemoglobin or hematocrit measurement. 864.8165 Section 864.8165 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864...

  9. Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study.

    Science.gov (United States)

    De Kesel, Pieter M M; Lambert, Willy E; Stove, Christophe P

    2015-06-30

    Volumetric absorptive microsampling (VAMS) is a novel sampling technique that allows the straightforward collection of an accurate volume of blood (approximately 10μL) from a drop or pool of blood by dipping an absorbent polymeric tip into it. The resulting blood microsample is dried and analyzed as a whole. The aim of this study was to evaluate the potential of VAMS to overcome the hematocrit bias, an important issue in the analysis of dried blood microsamples. An LC-MS/MS method for analysis of the model compounds caffeine and paraxanthine in VAMS samples was fully validated and fulfilled all pre-established criteria. In conjunction with previously validated procedures for dried blood spots (DBS) and blood, this allowed us to set up a meticulous comparative study in which both compounds were determined in over 80 corresponding VAMS, DBS and liquid whole blood samples. These originated from authentic human patient samples, covering a wide hematocrit range (0.21-0.50). By calculating the differences with reference whole blood concentrations, we found that analyte concentrations in VAMS samples were not affected by a bias that changed over the evaluated hematocrit range, in contrast to DBS results. However, VAMS concentrations tend to overestimate whole blood concentrations, as a consistent positive bias was observed. A different behavior of VAMS samples prepared from incurred and spiked blood, combined with a somewhat reduced recovery of caffeine and paraxanthine from VAMS tips at high hematocrit values, an effect that was not observed for DBS using a very similar extraction procedure, was found to be at the basis of the observed VAMS-whole blood deviations. Based on this study, being the first in which the validity and robustness of VAMS is evaluated by analyzing incurred human samples, it can be concluded that VAMS effectively assists in eliminating the effect of hematocrit. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Operative risk and preoperative hematocrit in bypass graft surgery: Role of gender and blood transfusion.

    Science.gov (United States)

    Ad, Niv; Holmes, Sari D; Massimiano, Paul S; Spiegelstein, Dan; Shuman, Deborah J; Pritchard, Graciela; Halpin, Linda

    2015-01-01

    The association between lower preoperative hematocrit (Hct) and risk for morbidity/mortality after cardiac surgery is well established. We examined whether the impact of low preoperative Hct on outcome is modified by blood transfusion and operative risk in women and men undergoing nonemergent CABG surgery. Patients having nonemergent, first-time, isolated CABG were included (N=2757). Logistic regressions assessed effect of hematocrit on major perioperative morbidity/mortality separately by males (n=2232) and females (n=525). Mean age was 63.2±10.1years, preoperative hematocrit was 38.9±4.8%, and STS risk score was 1.3±1.8%. Blood transfusion was more likely in female patients (26% vs. 12%, Ptransfusion in males and females, whereas older age (OR=1.03, P=0.017) also predicted transfusion in females. Major morbidity was also more likely in female patients (12% vs. 7%, Pblood transfusion was the only predictive factor for major morbidity in females (OR=4.56, Pblood transfusion (OR=9.22, Pblood transfusion and major morbidities after nonemergent CABG. Traditional factors that have been found to predict outcomes, such as hematocrit and STS risk, were related only to major morbidity in male patients. However, blood transfusion negatively impacted major outcome after nonemergent CABG surgery across all STS risk levels in both genders. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    Science.gov (United States)

    Steinfelder-Visscher, J; Weerwind, P W; Teerenstra, S; Brouwer, M H J

    2006-01-01

    Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the GEM Premier 3000 was compared with the Ciba Corning 865 analyser for blood gas/electrolytes/metabolites, and for hematocrit with the Sysmex XE 2100 instrument. During a 6-month period, 127 blood samples were analysed on both the GEM Premier 3000 analyser and our laboratory analysers (Ciba Corning 865/Sysmex 2100 instrument), and compared using the agreement analysis for quantitative data. With the exception of K+, the other parameters (pCO2, pO2, Na+, Ca2+, hematocrit, glucose, and lactate) can be described in terms of the mean and standard deviation of the differences. For K+ measurement, a clear linear trend (r=0.79, panalyser seems to be suitable for point-of-care testing of electrolytes, metabolites, and blood gases during cardiopulmonary bypass. However, its downward bias in hematocrit values below 30% suggests that using the GEM Premier 3000 as a transfusion trigger leads to overtreatment with packed red cells.

  12. [Sensitivity, specificity, and predictive values of the level of hemoglobin, hematocrit and platelet count as an activity index in ulcerative colitis].

    Science.gov (United States)

    Ibarra-Rodríguez, J Jesús; Santiago-Luna, Ernesto; Velázquez-Ramírez, Gabriela Abigail; López-Ramírez, María Karina Lizbeth; Fuentes-Orozco, Clotilde; Cortés-Flores, Ana Olivia; González-Ojeda, Alejandro

    2005-01-01

    Ulcerative colitis (UC) is a disease characterized by relapsing and remitting non-infectious inflammation of the colorectal mucosa. Its heterogeneity makes assessment of the disease's activity a prerequisite for a rational choice of therapy. We aimed to determine sensitivity, specificity, positive and negative predictive values of hemoglobin, hematocrit, and platelets to develop a simplified activity index of UC. Sixty patients with UC were included and submitted to measurements of hemoglobin, hematocrit, and platelets, as well as sigmoidoscopy and biopsy. Sensitivity and specificity, positive and negative predictive values were correlated with the reported degree of activity in the biopsy. Kruskal-Wallis test was used to determine differences between groups, and Pearson and Spearman rank tests were used to correlate each parameter with the degree of activity. A p value hemoglobin level was 51% and 100% for hematocrit, respectively, 51% and 100% for hematocrit, and 84% and 100% for platelet counts. Spearman's correlation for hemoglobin was r = -0.866 (p hematocrit r = -0.864 (p Hemoglobin and hematocrit are useful to catalog the degree of activity of UC when it is severe. Platelet count may be a marker of severity at any time, due to its high sensitivity and specificity as a diagnostic test.

  13. Radiosensitization by hematocrit manipulation

    International Nuclear Information System (INIS)

    Hirst, D.G.; Hazlehurst, J.L.; Brown, J.M.

    1985-01-01

    The authors show that tumors in mice adapt to anemia in a rather complex manner. Radiosensitivity may be lower, higher or equal to normal depending on when the anemia is induced prior to irradiation. The authors study these changes in radiosensitivity which occur during a period of anemia followed by the restoration of the hematocrit. When mice were made anemic immediately before irradiation, their tumors were very resistant, but the resistance was lost over the following 24 hrs even though the anemia was maintained. If mice which had been anemic for 24 hrs were retransfused to normal levels with red blood cells immediately before irradiation, their tumors were considerably more sensitive than normal. As the interval between retransfusion and irradiation was increased, sensitization was rapidly lost so that by 24 hrs sensitivity was the same as that of control tumors. They attribute this loss of sensitization to rapid tumor growth in response to a restored oxygen supply so that new hypoxic cells are created. The implications of this for the treatment of the anemic patient are discussed

  14. Hematocrit and plasma osmolality values of young-of-year shortnose sturgeon following acute exposures to combinations of salinity and temperature

    Science.gov (United States)

    Ziegeweid, J.R.; Black, M.C.

    2010-01-01

    Little is known about the physiological capabilities of young-of-year (YOY) shortnose sturgeon. In this study, plasma osmolality and hematocrit values were measured for YOY shortnose sturgeon following 48-h exposures to 12 different combinations of salinity and temperature. Hematocrit levels varied significantly with temperature and age, and plasma osmolalities varied significantly with salinity and age. Plasma osmolality and hematocrit values were similar to previously published values for other sturgeons of similar age and size in similar treatment conditions. ?? 2010 Springer Science+Business Media B.V.

  15. Hematocrit correction does not improve glucose monitor accuracy in the assessment of neonatal hypoglycemia.

    Science.gov (United States)

    Wang, Li; Sievenpiper, John L; de Souza, Russell J; Thomaz, Michele; Blatz, Susan; Grey, Vijaylaxmi; Fusch, Christoph; Balion, Cynthia

    2013-08-01

    The lack of accuracy of point of care (POC) glucose monitors has limited their use in the diagnosis of neonatal hypoglycemia. Hematocrit plays an important role in explaining discordant results. The objective of this study was to to assess the effect of hematocrit on the diagnostic performance of Abbott Precision Xceed Pro (PXP) and Nova StatStrip (StatStrip) monitors in neonates. All blood samples ordered for laboratory glucose measurement were analyzed using the PXP and StatStrip and compared with the laboratory analyzer (ABL 800 Blood Gas analyzer [ABL]). Acceptable error targets were ±15% for glucose monitoring and ±5% for diagnosis. A total of 307 samples from 176 neonates were analyzed. Overall, 90% of StatStrip and 75% of PXP values met the 15% error limit and 45% of StatStrip and 32% of PXP values met the 5% error limit. At glucose concentrations ≤4 mmol/L, 83% of StatStrip and 79% of PXP values met the 15% error limit, while 37% of StatStrip and 38% of PXP values met the 5% error limit. Hematocrit explained 7.4% of the difference between the PXP and ABL whereas it accounted for only 0.09% of the difference between the StatStrip and ABL. The ROC analysis showed the screening cut point with the best performance for identifying neonatal hypoglycemia was 3.2 mmol/L for StatStrip and 3.3 mmol/L for PXP. Despite a negligible hematocrit effect for the StatStrip, it did not achieve recommended error limits. The StatStrip and PXP glucose monitors remain suitable only for neonatal hypoglycemia screening with confirmation required from a laboratory analyzer.

  16. Hemoglobin and hematocrit at the end of hemodialysis: a better way to adjust erythropoietin dose?

    Science.gov (United States)

    Rangel, Erika B; Andreoli, Maria Claudia; Matos, Ana Cristina C; Guimarães-Souza, Nadia K; Mallet, Ana Cláudia; Carneiro, Fabiana D; Santos, Bento C

    2010-04-01

    A severe disadvantage of administration of recombinant human erythropoietin to hemodialysis patients has been reported. A significant correlation has been shown with hemoglobin values determined online by use of the blood volume monitor (BVM) and by laboratory measurement. Online hemoglobin and hematocrit were measured by use of the BVM during hemodialysis session. Data were analyzed by t test and statistical significance was defined as a P of hemoglobin and hematocrit from 11.6 +/- 1.9 to 13.9 +/- 2.4 g/dL (17.4 +/- 7.1%, P = 0.02) and from 34.4 +/- 6.8 to 42 +/- 8.3% (20.6 +/- 8.8%, P = 0.022), respectively, were observed from the beginning to the end of dialysis. We hypothesize that a new strategy for adjusting erythropoietin dose may be based on hemoglobin and hematocrit values evaluated at the end of hemodialysis, when patients are no longer hypervolemic. Inadvertent high levels of hemoglobin could be one explanation why patients present higher rates of cardiovascular and access-related events, especially when monitored online by use of the BVM to achieve the dry weight.

  17. Lack of utility of repeat monitoring of hemoglobin and hematocrit following blunt solid organ injury in children.

    Science.gov (United States)

    Acker, Shannon N; Petrun, Branden; Partrick, David A; Roosevelt, Genie E; Bensard, Denis D

    2015-12-01

    Current management protocols for children with blunt solid organ injury to the liver and spleen call for serial monitoring of the child's hemoglobin and hematocrit every 6, 12, or 24 hours, depending on the injury grade. We hypothesized that children who require emergent intervention in the form of laparotomy, angioembolization, or packed red blood cell (PRBC) transfusion because of bleeding from a solid organ injury will have changes in their vital signs that alert the clinician to the need for intervention, making scheduled laboratory evaluation unnecessary. We performed a retrospective review of all children admitted to either of two pediatric trauma centers following blunt trauma with any grade liver or spleen injury from January 2009 to December 2013. Data evaluated include a need for intervention, indication for intervention, and timing of intervention. A total of 245 children were admitted with blunt liver or spleen injury. Six patients (2.5%) underwent emergent exploratory laparotomy for hypotension a median of 4 hours after injury (range, 2-4 hours), four of who required splenectomy. No child required laparotomy for delayed bleeding from a solid organ injury. One child (0.4%) underwent angioembolization for blunt splenic injury. Forty-one children (16.7%) received a PRBC transfusion during hospitalization, 32 of whom did not undergo laparotomy or angioembolization. Children who underwent an intervention had a lower nadir hematocrit (median, 22.9 vs. 32.8; p hematocrit (median, 35.5 vs. 16 hours; p hemoglobin and hematocrit monitoring (median, 20 vs. 5; p hemoglobin and hematocrit values may not be necessary. Retrospective study with no negative criteria, prognostic study, level III.

  18. Influence of Ringer’s lactated solution in continuous infusion and general anesthesia on hematocrit in dogs

    Directory of Open Access Journals (Sweden)

    Rogério Luizari Guedes

    2015-08-01

    Full Text Available The measurement of serum parameters during general anesthesia procedures are subject to variations due to differences in protocol, splenic storage, and by the instituted fluid therapy. The aim of this study was to assess the hematocrit changes promoted by controlled fluid therapy and general anesthesia. Six mongrel female dogs underwent an anesthetic protocol with acepromazine (0.03 mg kg-1 and tramadol (5 mg kg-1 for premedication, induction with propofol (3 mg kg-1, and maintained with isoflurane and mechanical ventilation for 120 minutes. After induction, they were infused with 10 ml kg hr-1 of Ringer’s lactate solution. Hematocrit measurements were performed from the start until 72 hours from anesthesia and evaluated statistically to check if there were significant changes over time. The fluid therapy, the acepromazine and propofol in the anesthetic protocol promotes a significant reduction of hematocrit up to four hours after general anesthesia.

  19. Innocent Cardiac Murmur in Puppies : Prevalence, Correlation with Hematocrit, and Auscultation Characteristics

    NARCIS (Netherlands)

    Szatmári, V; van Leeuwen, M W; Teske, E

    2015-01-01

    BACKGROUND: The aims of this study were to establish the prevalence of innocent cardiac murmurs in clinically healthy puppies, to investigate a possible correlation between the presence of an innocent murmur and hematocrit, and to describe the auscultation characteristics of innocent murmurs.

  20. The use of regression analysis in determining reference intervals for low hematocrit and thrombocyte count in multiple electrode aggregometry and platelet function analyzer 100 testing of platelet function.

    Science.gov (United States)

    Kuiper, Gerhardus J A J M; Houben, Rik; Wetzels, Rick J H; Verhezen, Paul W M; Oerle, Rene van; Ten Cate, Hugo; Henskens, Yvonne M C; Lancé, Marcus D

    2017-11-01

    Low platelet counts and hematocrit levels hinder whole blood point-of-care testing of platelet function. Thus far, no reference ranges for MEA (multiple electrode aggregometry) and PFA-100 (platelet function analyzer 100) devices exist for low ranges. Through dilution methods of volunteer whole blood, platelet function at low ranges of platelet count and hematocrit levels was assessed on MEA for four agonists and for PFA-100 in two cartridges. Using (multiple) regression analysis, 95% reference intervals were computed for these low ranges. Low platelet counts affected MEA in a positive correlation (all agonists showed r 2 ≥ 0.75) and PFA-100 in an inverse correlation (closure times were prolonged with lower platelet counts). Lowered hematocrit did not affect MEA testing, except for arachidonic acid activation (ASPI), which showed a weak positive correlation (r 2 = 0.14). Closure time on PFA-100 testing was inversely correlated with hematocrit for both cartridges. Regression analysis revealed different 95% reference intervals in comparison with originally established intervals for both MEA and PFA-100 in low platelet or hematocrit conditions. Multiple regression analysis of ASPI and both tests on the PFA-100 for combined low platelet and hematocrit conditions revealed that only PFA-100 testing should be adjusted for both thrombocytopenia and anemia. 95% reference intervals were calculated using multiple regression analysis. However, coefficients of determination of PFA-100 were poor, and some variance remained unexplained. Thus, in this pilot study using (multiple) regression analysis, we could establish reference intervals of platelet function in anemia and thrombocytopenia conditions on PFA-100 and in thrombocytopenia conditions on MEA.

  1. THE RELATIONSHIP BETWEEN HEMOGLOBIN AND HEMATOCRIT IN THE FIRST TRIMESTER OF PREGNANCY AND THE INCIDENCE OF PREECLAMPSIA

    OpenAIRE

    Fateme parooei , Mahmood Anbari, Morteza Salarzaei *

    2017-01-01

    Introduction: Pregnancy and childbirth are among the most important events in every woman’s life. Although pregnancy is not a disease and is a physiological and natural process, it may be followed with complications, and pregnancy cares can prevent the incidence of many problems. Methods: In this review article, the databases Medline, Cochrane, Science Direct, and Google Scholar were thoroughly searched to identify the relationship between hemoglobin and hematocrit in the first trimester of p...

  2. Radioprotective properties of some heterocyclic nitrogenous compounds against changes in hemoglobin concentration and hematocrit value in x-irradiated mice; Proprietes radioprotectrices de certains composes heterocycliques azotes sur les variations du taux d'hemoglobine et de la valeur hematocrite chez la souris irradiee

    Energy Technology Data Exchange (ETDEWEB)

    Rousdhy, H; Pierotti, T; Polverelli, M [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Radioprotective properties of imidazole and benzimidazole have been proved in previous works. In this study, authors try to demonstrate radioprotective action of these compounds in comparison with cysteamine upon the hematopoietic system after lethal X-irradiation. Results show: no drastic variations of hematologic constants (hemoglobin concentration and hematocrit value) after intraperitoneal injection of radioprotective compounds apart certain apparent reactions with the heterocyclic compounds; the better radioprotective action of benzimidazole. Twenty five days after irradiation, hemoglobin concentration and hematocrit of radio protected mice return to normal values. (author) [French] Les proprietes radioprotectrices de l'imidazole et du benzimidazole ayant ete demontrees dans de precedents travaux, les auteurs se sont attaches a etudier l'action de ces produits sur le systeme hematopofetique en comparaison avec celle de la cysteamine, apres une irradiation a dose letale. A l'aide des criteres choisis, les resultats demontrent: qu'en dehors de certaines reactions apparentes, succedant a l'injection intraperitoneale des heterocycles azotes, les constantes hematologiques (taux d'hemoglobine et valeur hematocrite) ne sont que legerement modifiees; la superiorite du benzimidazole sur les autres produits utilises. Enfin, le vingt-cinquieme jour apres irradiation, les souris protegees par les heterocycles azotes ont un taux d'hemoglobine et une valeur hematocrite tout a fait normaux. (auteur)

  3. Elevated capillary tube hematocrit reflects degradation of endothelial cell glycocalyx by oxidized LDL

    NARCIS (Netherlands)

    Constantinescu, A. A.; Vink, H.; Spaan, J. A.

    2001-01-01

    Proteoglycans and plasma proteins bound to the endothelial cell glycocalyx are essential for vascular function, but at the same time, they lower capillary tube hematocrit by reducing capillary volume available to flowing blood. Because oxidized low-density lipoproteins (oxLDL) reduce the effective

  4. Effect of ionic and non-ionic contrast media on whole blood viscosity, plasma viscosity and hematocrit in vitro

    International Nuclear Information System (INIS)

    Aspelin, P.

    1978-01-01

    The effect of the ionic contrast media diatrizoate, iocarmate and metrizoate and the non-ionic metrizamide on whole blood viscosity, plasma viscosity and hematocrit was investigated. All the contrast media increased whole blood and plasma viscosity and reduced the hematocrit. The whole blood viscosity increased with increasing osmolality of the contrast medium solutions, whereas the plasma viscosity increased with increasing viscosity of the contrast medium solutions. The higher the osmolality of the contrast media, the lower the hematocrit became. The normal shear-thinning (decreasing viscosity with increasing shear rate) property of blood was reduced when contrast medium was added to the blood. At 50 per cent volume ratio (contrast medium to blood), the ionic contrast media converted the blood into a shear-thickening (increasing viscosity with increasing shear rate) suspension, indicating a marked rigidification of the single red cell, while the non-ionic contrast medium still produced shear-thinning, indicating less rigidification of the red cell (p<0.01). (Auth.)

  5. Hematocrit and Serum Hemoglobin Do Not Influence Values in Computed Tomography Perfusion of Patients With Acute Ischemic Stroke.

    Science.gov (United States)

    Karwacki, Grzegorz Marek; Benz, Matthias Richard; Tyndall, Anthony Joseph; Ulmer, Stephan

    There is a correlation between both serum hemoglobin (HGB) and hematocrit (HCT) and attenuation values of vessels in noncontrast-enhanced computed tomography (NECT), which could influence calculated perfusion maps in CT perfusion. We retrospectively included 45 patients, who presented with acute new neurological symptoms and underwent NECT and CT perfusion (128-row multi detector scanner, coverage: 6.9 cm craniocaudally; 80 kV; 200 mAs; temporal resolution: 2 seconds using 40 mL Ultravist 370 at a flow rate of 5 mL/s) on admission and a follow-up MRI within 1 week of admission. Hematocrit, HGB, and attenuation values did not differ between patients with stroke and controls. A statistically significant correlation was found between HCT and HGB and attenuation values in the internal carotid artery or middle cerebral artery on NECT (P Hematocrit and HGB do not influence calculated perfusion maps. There is no need for HCT/HGB-adjusted cerebral blood volume thresholds in stroke patients.

  6. Retrospective review of hemoglobin and/or hematocrit levels with occurrence of thrombosis in cancer patients treated with erythropoiesis stimulating agents.

    Science.gov (United States)

    Fullmer, Amber C; Miller, Rickey

    2009-09-01

    No data exists that directly compares hemoglobin and hematocrit levels between cancer patients with and without occurrence of thrombosis during treatment with erythropoiesis stimulating agents (ESAs). To determine the association of hemoglobin and hematocrit levels with the occurrence of thrombosis in cancer patients treated with ESAs. A retrospective case-control study approved by the Institutional Review Board was conducted on cancer patients billed for epoetin or darbepoetin between 1 July 2002 and 30 June 2007. Cases were defined as patients billed for thrombosis while controls were defined as patients not billed for thrombosis. Sixteen patients had an occurrence of thrombosis (cases) and were matched to 16 patients that did not have an occurrence of thrombosis (controls) based on age, sex, and cancer type. The mean peak hemoglobin levels for cases and controls were 12.6 +/- 1.2 g/dL versus 12.6 +/- 1.4 g/dL (p = 0.9). The mean peak hematocrit levels for cases and controls were 37.3 +/- 3.8% versus 37.9 +/- 4.3% (p = 0.8). For the 16/586 (2.7%) patients with thrombosis, the mean hemoglobin and hematocrit at time of thrombosis were 9.6 +/- 1.0 g/dL and 28.9 +/- 3.1%. A significant identifiable risk factor for thrombosis between the cases and controls was history of thrombosis 31.3% versus 0% (p = 0.04). There was no statistical difference in peak hemoglobin and hematocrit levels between patients with thrombosis and those without thrombosis. Further study is warranted to determine if these levels are true risk factors for thrombosis.

  7. HEMOGLOBIN AND HEMATOCRITE CHANGES DURING UNCOMPLICATED ANESTHESIA: GENERAL ANESTHESIA AND LOCAL ANESTHESIA

    Directory of Open Access Journals (Sweden)

    KH NAGHIBI

    2002-12-01

    Full Text Available Introduction. Despite of vital role of blood and it"s components as an only curable treatment, it"s transfusion is accompanied by many complications. In the other way, the most important adverse effects of anemia is decrease in oxygen supply to the tissues. Therefore, it is essential to determine those patients need to blood transfusion and exact hemoglobine and hematocrite level which transfusion become necessary. Recent studies show that during general anesthesia due to vasodilation in the level of microcirculation and passage of many red blood cells from microcirculation there is a decreasing in hemoglobine level measured in peripheral veins which named plasma skimming. So, during sampling of hemoglobine and hematocrite from peripheral veins, there is a pseudodecrease in Hb and HCT levels. In this study we want to determine this decrease in Hb and HeT. Methods. Study was done in 182 patients with ASA 1 and 2 undergoing general or local anesthesia for cataract surgery. Duration of nill per os (NPO, preoperotive and intraoperative intravenous fluid administration were simillar in two groups. A sample of blood for preoperative evaluation and another one immediately after operation achevied and compared with each other. Results. There was not significant differences between mean Hb and HCT in two groups preoperotive. But postoperative, there was a significant differences between mean Hb and HCT in general anesthesia vs local anesthesia (P < 0.01. This decrease in Hb and HCT was orderly 0.91 ± 1.14 gr/dl for Hb and 2.862±3.6 percent for Hct. Discussion. In determining of Hb and HCT immediately after general anesthesia, there is some pseudo decrease due to plasma skimming that must be appreciated.

  8. Effect of hematocrit and systolic blood pressure on cerebral blood flow in newborn infants

    International Nuclear Information System (INIS)

    Younkin, D.P.; Reivich, M.; Jaggi, J.L.; Obrist, W.D.; Delivoria-Papadopoulos, M.

    1987-01-01

    The effects of hematocrit and systolic blood pressure on cerebral blood flow were measured in 15 stable, low birth weight babies. CBF was measured with a modification of the xenon-133 ( 133 Xe) clearance technique, which uses an intravenous bolus of 133 Xe, an external chest detector to estimate arterial 133 Xe concentration, eight external cranial detectors to measure cephalic 133 Xe clearance curves, and a two-compartmental analysis of the cephalic 133 Xe clearance curves to estimate CBF. There was a significant inverse correlation between hematocrit and CBF, presumably due to alterations in arterial oxygen content and blood viscosity. Newborn CBF varied independently of systolic blood pressure between 60 and 84 mm Hg, suggesting an intact cerebrovascular autoregulatory mechanism. These results indicate that at least two of the factors that affect newborn animal CBF are operational in human newborns and may have important clinical implications

  9. Hematocrit levels as cardiovascular risk among taxi drivers in Bangkok, Thailand

    OpenAIRE

    ISHIMARU, Tomohiro; ARPHORN, Sara; JIRAPONGSUWAN, Ann

    2016-01-01

    In Thailand, taxi drivers employed in the informal sector often experience hazardous working conditions. Previous studies revealed that elevated Hematocrit (HCT) is a predictor of cardiovascular disease (CVD) risk. This study assessed factors associated with HCT in taxi drivers to predict their occupational CVD risk factors. A cross-sectional study was conducted on 298 male taxi drivers who joined a health check-up campaign in Bangkok, Thailand. HCT and body mass index were retrieved from par...

  10. Radioprotective properties of some heterocyclic nitrogenous compounds against changes in hemoglobin concentration and hematocrit value in x-irradiated mice

    International Nuclear Information System (INIS)

    Rousdhy, H.; Pierotti, T.; Polverelli, M.

    1969-01-01

    Radioprotective properties of imidazole and benzimidazole have been proved in previous works. In this study, authors try to demonstrate radioprotective action of these compounds in comparison with cysteamine upon the hematopoietic system after lethal X-irradiation. Results show: no drastic variations of hematologic constants (hemoglobin concentration and hematocrit value) after intraperitoneal injection of radioprotective compounds apart certain apparent reactions with the heterocyclic compounds; the better radioprotective action of benzimidazole. Twenty five days after irradiation, hemoglobin concentration and hematocrit of radio protected mice return to normal values. (author) [fr

  11. Blood Glucose Meters Employing Dynamic Electrochemistry Are Stable against Hematocrit Interference in a Laboratory Setting

    Science.gov (United States)

    Pfützner, Andreas; Musholt, Petra B.; Schipper, Christina; Demircik, Filiz; Hengesbach, Carina; Flacke, Frank; Sieber, Jochen; Forst, Thomas

    2013-01-01

    Background Hematocrit (HCT) is known to be a confounding factor that interferes with many blood glucose (BG) measurement technologies, resulting in wrong readings. Dynamic electrochemistry has been identified as one possible way to correct for these potential deviations. The purpose of this laboratory investigation was to assess the HCT stability of four BG meters known to employ dynamic electrochemistry (BGStar and iBGStar, Sanofi; Wavesense Jazz, AgaMatrix; Wellion Linus, MedTrust) in comparison with three other devices (GlucoDock, Medisana; OneTouch Verio Pro, LifeScan; FreeStyle Freedom InsuLinx, Abbott-Medisense). Methods Venous heparinized blood was immediately aliquoted after draw and manipulated to contain three different BG concentrations (60–90, 130–160, and 280–320 mg/dl) and five different HCT levels (25%, 35%, 45%, 55%, and 60%). After careful oxygenation to normal blood oxygen pressure, each of the resulting 15 different samples was measured six times with three devices and three strip lots of each meter. The YSI Stat 2300 served as laboratory reference method. Stability to HCT influence was assumed when less than 10% difference occurred between the highest and lowest mean glucose deviations in relation to HCT concentrations [hematocrit interference factor (HIF)]. Results Five of the investigated self-test meters showed a stable performance with the different HCT levels tested in this investigation: BGStar (HIF 4.6%), iBGStar (6.6%), Wavesense Jazz (4.1%), Wellion Linus (8.5%), and OneTouch Verio Pro (6.2%). The two other meters were influenced by HCT (FreeStyle InsuLinx 17.8%; GlucoDock 46.5%). Conclusions In this study, meters employing dynamic electrochemistry, as used in the BGStar and iBGStar devices, were shown to correct for potential HCT influence on the meter results. Dynamic electrochemistry appears to be an effective way to handle this interfering condition. PMID:24351179

  12. The effect of zinc and vitamin C supplementation on hemoglobin and hematocrit levels and immune response in patients with Plasmodium vivax malaria.

    Science.gov (United States)

    Zen Rahfiludin, M; Ginandjar, Praba

    2013-09-01

    Plasmodium vivax infection in humans can relapse and is associated with iron deficiency. The immune response plays an important role in preventing relapse. In this study we analyzed the effect of zinc and vitamin C supplementation on hemoglobin and hematocrit levels and immune response in patients with P. vivax malaria. We measured immune response by examining interferon gamma (IFN-gamma) and interleukin-10 (IL-10) levels. Subjects were divided into either treatment or control groups. The treatment group received daily zinc and vitamin C supplementation for 45 days. Compliance with supplement consumption was recorded weekly. After 45 days of supplementation, IFN-gamma and IL-1 levels were remeasured. All study subjects in both groups had normal hemoglobin and hematocrit levels. The hemoglobin levels increased only in the supplementation group (p=0.011), while hematocrit levels increased in both the supplementation (p=0.001) and control (p=0.023) groups. IFN-gamma decreased slightly in the supplementation group, but the change was not significant (p=0.688). IL-10 increased slightly in both the supplementation and the control groups, but the change were not significant (p=0.421 and p=0.556, respectively), suggesting the elevated hemoglobin and hematocrit levels were unrelated to immune response.

  13. The initial decrease in effective peritoneal surface area is not caused by an increase in hematocrit

    NARCIS (Netherlands)

    Struijk, D. G.; Krediet, R. T.; Koomen, G. C.; Boeschoten, E. W.; Hoek, F. J.; Arisz, L.

    1993-01-01

    The possible relationship between initial changes in functional characteristics of the peritoneal membrane in time and hemoglobin (Hb) or hematocrit (Ht) was analyzed as part of a prospective longitudinal study. The patients were investigated twice: the first time within 3 months after the start of

  14. Blood glucose meters employing dynamic electrochemistry are stable against hematocrit interference in a laboratory setting.

    Science.gov (United States)

    Pfützner, Andreas; Musholt, Petra B; Schipper, Christina; Demircik, Filiz; Hengesbach, Carina; Flacke, Frank; Sieber, Jochen; Forst, Thomas

    2013-11-01

    Hematocrit (HCT) is known to be a confounding factor that interferes with many blood glucose (BG) measurement technologies, resulting in wrong readings. Dynamic electrochemistry has been identified as one possible way to correct for these potential deviations. The purpose of this laboratory investigation was to assess the HCT stability of four BG meters known to employ dynamic electrochemistry (BGStar and iBGStar, Sanofi; Wavesense Jazz, AgaMatrix; Wellion Linus, MedTrust) in comparison with three other devices (GlucoDock, Medisana; OneTouch Verio Pro, LifeScan; FreeStyle Freedom InsuLinx, Abbott-Medisense). Venous heparinized blood was immediately aliquoted after draw and manipulated to contain three different BG concentrations (60-90, 130-160, and 280-320 mg/dl) and five different HCT levels (25%, 35%, 45%, 55%, and 60%). After careful oxygenation to normal blood oxygen pressure, each of the resulting 15 different samples was measured six times with three devices and three strip lots of each meter. The YSI Stat 2300 served as laboratory reference method. Stability to HCT influence was assumed when less than 10% difference occurred between the highest and lowest mean glucose deviations in relation to HCT concentrations [hematocrit interference factor (HIF)]. Five of the investigated self-test meters showed a stable performance with the different HCT levels tested in this investigation: BGStar (HIF 4.6%), iBGStar (6.6%), Wavesense Jazz (4.1%), Wellion Linus (8.5%), and OneTouch Verio Pro (6.2%). The two other meters were influenced by HCT (FreeStyle InsuLinx 17.8%; GlucoDock 46.5%). In this study, meters employing dynamic electrochemistry, as used in the BGStar and iBGStar devices, were shown to correct for potential HCT influence on the meter results. Dynamic electrochemistry appears to be an effective way to handle this interfering condition. © 2013 Diabetes Technology Society.

  15. 70-year old female patient with mismatch between hematocrit and hemoglobin values: the effects of cold agglutinin on complete blood count.

    Science.gov (United States)

    Ercan, Serif; Calışkan, Mustafa; Koptur, Erhan

    2014-01-01

    There are a number of pre-analytical and analytical factors, which cause false results in the complete blood count. The present case identifies cold agglutinins as the cause for the mismatch between hematocrit and hemoglobin values. 70-year old female patient had a history of cerebrovascular diseases and rheumatoid arthritis. During routine laboratory examination, the patient had normal leukocyte and platelet counts; however, the hemoglobin (Hb: 105 g/L) and hematocrit (HCT: 0.214 L/L) results were discordant. Hemolysis, lipemia and cold agglutinin were evaluated as possible reasons for the mismatch between hematocrit and hemoglobin values. First blood sample was slightly hemolysed. Redrawn sample without hemolysis or lipemia was analyzed but the mismatch became even more distinct (Hb: 104 g/L and HCT: 0.08 L/L). In this sample, the titration of the cold agglutinin was determined and found to be positive at 1:64 dilution ratios. After an incubation of the sample at 37°C for 2 hours, reversibility of agglutination was observed. We conclude that cold agglutinins may interfere with the analysis of erythrocyte and erythrocyte-related parameters (HCT, MCV, MCH and MCHC); however, Hb, leukocyte and platelet counts are not affected.

  16. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    NARCIS (Netherlands)

    Steinfelder-Visscher, J.; Weerwind, P.W.; Teerenstra, S.; Brouwer, René

    2006-01-01

    BACKGROUND: Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the

  17. [Differences between observed and estimated by hematocrit hemoglobin and its relevance in the diagnosis of anemia among coastal population in Venezuela: analysis of the second national study of human growth and development (SENACREDH)].

    Science.gov (United States)

    Flores-Torres, Jessica; Echeverría-Ortega, María; Arria-Bohorquez, Melissa; Hidalgo, Glida; Albano-Ramos, Carlos; Sanz, Rafael; Rodríguez-Morales, Alfonso J

    2011-03-01

    To evaluate the differences between the observed hemoglobin levels and those estimated based on hematocrit in the context of the 2nd National Study of Human Growth and Development of the Venezuelan Population (SENACREDH). 6,004 individuals were chosen by a probabilistic multistage cluster sampling representing 7,286,781 inhabitants from North Central Coastal area (Vargas, Carabobo, Capital District, Aragua and Miranda). Means of observed and estimated hemoglobin (hematocrit/3) were compared, using t test for related samples and linear regression. Mean difference between the values of observed and estimated hemoglobin was -0.3446 ±0.0002 (phemoglobin values. Regression models of hemoglobin on hematocrit showed an r2=0,87. In order to correct the estimation, we propose a new formula for calculating hemoglobin based on haematocrit values: estimated hemoglobin=(Haematocrit/3.135)+ 0.257. There is an overestimation of hemoglobin levels from hematocrit levels and therefore an underestimation of the prevalence of anemia; however, a high positive correlation between them was found, allowing modeling for achieving a better estimation of the hemoglobin from the hematocrit value.

  18. Modification of hemoglobin level and hematocrit value in the peripheral blood of mice after 45Ca internal irradiation by MPG (2-mercaptopropionylglycine)

    International Nuclear Information System (INIS)

    Bhagat, R.M.; Kumar, A.

    1986-01-01

    Radioprotective effect of MPG has been studied on the hemoglobin level and hematocrit value of peripheral blood of Swiss albino mice against radiation-induced changes after injecting radiocalcium ( 45 Ca) at the dose level of 37 kBq/g body weight. MPG was injected 15-30 minutes before 45 Ca injection at dose of 20 mg/kg body weight intraperitoneally and also MPG was injected at various repeated doses. It has been observed that MPG in repeated doses is effective in reducing the radiation-induced changes in the hemoglobin and hematocrit value of peripheral blood of Swiss albino mice following 45 Ca internal irradiation. (author)

  19. A Semi-Physiological Population Model to Quantify the Effect of Hematocrit on Everolimus Pharmacokinetics and Pharmacodynamics in Cancer Patients

    NARCIS (Netherlands)

    Erp, N.P. van; Herpen, C.M. van; Wit, D. de; Willemsen, A.; Burger, D.M.; Huitema, A.D.; Kapiteijn, E.; Heine, R. ter

    2016-01-01

    INTRODUCTION AND OBJECTIVE: Everolimus (a drug from the class of mammalian target of rapamycin [mTOR] inhibitors) is associated with frequent toxicity-related dose reductions. Everolimus accumulates in erythrocytes, but the extent to which hematocrit affects everolimus plasma pharmacokinetics and

  20. The risk factors of perioperative hemoglobin and hematocrit drop after intramedullary nailing treatment for intertrochanteric fracture patients.

    Science.gov (United States)

    Wang, Jun; Wei, Jie; Wang, Manyi

    2015-01-01

    The objective of this study was to analyze the risk factors associated with the hemoglobin and hematocrit drops in the early postoperative period for intertrochanteric fracture patients with intramedullary nailing treatment. From January 2003 to December 2013, 634 intertrochanteric fracture patients with complete information were recruited into the study. Their age, gender, operating time, medical diseases, blood routine examination at admission and postoperative first day, and the days between the trauma and operation were recorded. The hemoglobin (HGB) change of patients (75 years) (P = 0.039). Meanwhile, the change of hematocrit (HCT) level of patients (75 years), but the difference was not significant (P = 0.062). The gender had no significant influence on HCT and HGB. The HGB and HCT change of patients with diabetes (ΔHCT, 8.47 ± 3.36 %; ΔHGB, 29.19 ± 13.10 g/l) were statistically greater than that of patients without diabetes (ΔHCT, 5.52 ± 3.84 %; ΔHGB, 19.81 ± 14.68 g/l) (P = 0.006, P = 0.022). The hypertension and coronary heart disease had no significant influence on the change of HCT and HGB levels. The operation time had a significant influence on the change of HCT and HGB. The ΔHCT and ΔHGB in the group for which the time was more than 48 h between the trauma and operation were greater than that in the group with less than 48 h between the trauma and operation but not significantly different (ΔHCT, P = 0.672; ΔHGB, P = 0.66). The factors of age, medical disease such as diabetes, operation time, and time between the trauma and operation may be associated with the change of perioperative hemoglobin and hematocrit levels for intertrochanteric fracture patients after intramedullary nailing treatment in the early postoperative period.

  1. Diffuse and localized reflectance measurements of hemoglobin and hematocrit in human skin

    Science.gov (United States)

    Khalil, Omar S.; Wu, Xiaomao; Yeh, Shu-Jen; Jeng, Tzyy-Wen

    2001-05-01

    We conducted visible/near infrared optical measurements on the forearm of human subjects using a commercial diffuse reflectance spectrophotometer, and a breadboard temperature- controlled localized reflectance tissue photometer. Calibration relationships were established between skin reflectance signal and reference blood hemoglobin (Hb) concentration, or hematocrit values (Hct). These were then used to predict Hb and Hct values from optical measurement in a cross validation analysis. Different linear least- squares models for the prediction of Hb and Hct are presented and shows the ability to predict both. It was possible to screen prospective blood donors with low Hb concentration. It was possible to predict anemic subjects in the limited prospective blood donor population.

  2. Noninvasive in vivo plasma volume and hematocrit in humans: observing long-term baseline behavior to establish homeostasis for intravascular volume and composition

    Science.gov (United States)

    Dent, Paul; Deng, Bin; Goodisman, Jerry; Peterson, Charles M.; Narsipur, Sriram; Chaiken, J.

    2016-04-01

    A new device incorporating a new algorithm and measurement process allows simultaneous noninvasive in vivo monitoring of intravascular plasma volume and red blood cell volume. The purely optical technique involves probing fingertip skin with near infrared laser light and collecting the wavelength shifted light, that is, the inelastic emission (IE) which includes the unresolved Raman and fluorescence, and the un-shifted emission, that is, the elastic emission (EE) which includes both the Rayleigh and Mie scattered light. Our excitation and detection geometry is designed so that from these two simultaneous measurements we can calculate two parameters within the single scattering regime using radiation transfer theory, the intravascular plasma volume fraction and the red blood cell volume fraction. Previously calibrated against a gold standard FDA approved device, 2 hour monitoring sessions on three separate occasions over a three week span for a specific, motionless, and mostly sleeping individual produced 3 records containing a total of 5706 paired measurements of hematocrit and plasma volume. The average over the three runs, relative to the initial plasma volume taken as 100%, of the plasma volume±1σ was 97.56+/-0.55 or 0.56%.For the same three runs, the average relative hematocrit (Hct), referenced to an assumed initial value of 28.35 was 29.37+/-0.12 or stable to +/-0.4%.We observe local deterministic circulation effects apparently associated with the pressure applied by the finger probe as well as longer timescale behavior due to normal ebb and flow of internal fluids due to posture changes and tilt table induced gravity gradients.

  3. Decreased hematocrit-to-viscosity ratio and increased lactate dehydrogenase level in patients with sickle cell anemia and recurrent leg ulcers.

    Directory of Open Access Journals (Sweden)

    Philippe Connes

    Full Text Available Leg ulcer is a disabling complication in patients with sickle cell anemia (SCA but the exact pathophysiological mechanisms are unknown. The aim of this study was to identify the hematological and hemorheological alterations associated with recurrent leg ulcers. Sixty-two SCA patients who never experienced leg ulcers (ULC- and 13 SCA patients with a positive history of recurrent leg ulcers (ULC+--with no leg ulcers at the time of the study--were recruited. All patients were in steady state condition. Blood was sampled to perform hematological, biochemical (hemolytic markers and hemorheological analyses (blood viscosity, red blood cell deformability and aggregation properties. The hematocrit-to-viscosity ratio (HVR, which reflects the red blood cell oxygen transport efficiency, was calculated for each subject. Patients from the ULC+ group were older than patients from the ULC- group. Anemia (red blood cell count, hematocrit and hemoglobin levels was more pronounced in the ULC+ group. Lactate dehydrogenase level was higher in the ULC+ group than in the ULC- group. Neither blood viscosity, nor RBC aggregation properties differed between the two groups. HVR was lower and RBC deformability tended to be reduced in the ULC+ group. Our study confirmed increased hemolytic rate and anemia in SCA patients with leg ulcers recurrence. Furthermore, our data suggest that although systemic blood viscosity is not a major factor involved in the pathophysiology of this complication, decreased red blood cell oxygen transport efficiency (i.e., low hematocrit/viscosity ratio may play a role.

  4. Measurement of Flow Properties of Mammalian Blood with Different Hematocrit Values Using Falling Needle Rheometer

    Directory of Open Access Journals (Sweden)

    Takamasa Suzuki

    2014-08-01

    Full Text Available The development of viscometry with high accuracy and quick operation, as well as the establishment of a data evaluation method by pathology are largely required. Especially, the flow properties of human blood are an important factor in the evaluation of blood disease on the medicine, but the method of viscometry and the data collection are not so easy. This study has been described on the viscosity measurement and their evaluations for mammalian blood (rabbit, pig and horse including human blood. A compact-sized falling needle rheometer (FNR and a flow analysis method using this device for blood have been developed, and the relationship between the apparent viscosity and physical properties (density, hematocrit value of blood have also been evaluated. Measured flow properties of blood are evaluated as a flow curve showing the relationship between the shear stress and shear rate. Observed flow curves of mammalian bloods show three typical fluid regions, these are, the Non-newtonian fluid region for a low shear rate range, the transition region and the Newtonian fluid region for a high shear rate range. Flow properties of blood in the Casson fluid region and the apparent viscosity (μ in the Newtonian fluid region are measured, and they are compared between mammals.

  5. Non-invasive evaluation of blood oxygen saturation and hematocrit from T1 and T2 relaxation times: In-vitro validation in fetal blood.

    Science.gov (United States)

    Portnoy, Sharon; Seed, Mike; Sled, John G; Macgowan, Christopher K

    2017-12-01

    We propose an analytical method for calculating blood hematocrit (Hct) and oxygen saturation (sO 2 ) from measurements of its T 1 and T 2 relaxation times. Through algebraic substitution, established two-compartment relationships describing R1=T1-1 and R2=T2-1 as a function of hematocrit and oxygen saturation were rearranged to solve for Hct and sO 2 in terms of R 1 and R 2 . Resulting solutions for Hct and sO 2 are the roots of cubic polynomials. Feasibility of the method was established by comparison of Hct and sO 2 estimates obtained from relaxometry measurements (at 1.5 Tesla) in cord blood specimens to ground-truth values obtained by blood gas analysis. Monte Carlo simulations were also conducted to assess the effect of T 1 , T 2 measurement uncertainty on precision of Hct and sO 2 estimates. Good agreement was observed between estimated and ground-truth blood properties (bias = 0.01; 95% limits of agreement = ±0.13 for Hct and sO 2 ). Considering the combined effects of biological variability and random measurement noise, we estimate a typical uncertainty of ±0.1 for Hct, sO 2 estimates. Results demonstrate accurate quantification of Hct and sO 2 from T 1 and T 2 . This method is applicable to noninvasive fetal vessel oximetry-an application where existing oximetry devices are unusable or require risky blood-sampling procedures. Magn Reson Med 78:2352-2359, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  6. Cerebral oxygen transport failure?: decreasing hemoglobin and hematocrit levels after ischemic stroke predict poor outcome and mortality: STroke: RelevAnt Impact of hemoGlobin, Hematocrit and Transfusion (STRAIGHT)--an observational study.

    Science.gov (United States)

    Kellert, Lars; Martin, Evgenia; Sykora, Marek; Bauer, Harald; Gussmann, Philipp; Diedler, Jennifer; Herweh, Christian; Ringleb, Peter A; Hacke, Werner; Steiner, Thorsten; Bösel, Julian

    2011-10-01

    Although conceivably relevant for penumbra oxygenation, the optimal levels of hemoglobin (Hb) and hematocrit (Hct) in patients with acute ischemic stroke are unknown. We identified patients from our prospective local stroke database who received intravenous thrombolysis based on multimodal magnet resonance imaging during the years 1998 to 2009. A favorable outcome at 3 months was defined as a modified Rankin Scale score≤2 and a poor outcome as a modified Rankin Scale score≥3. The dynamics of Hemoglobin (Hb), Hematocrit (Hct), and other relevant laboratory parameters as well as cardiovascular risk factors were retrospectively assessed and analyzed between these 2 groups. Of 217 patients, 114 had a favorable and 103 a poor outcome. In a multivariable regression model, anemia until day 5 after admission (odds ratio [OR]=2.61; 95% CI, 1.33 to 5.11; P=0.005), Hb nadir (OR=0.81; 95% CI, 0.67 to 0.99; P=0.038), and Hct nadir (OR=0.93; 95% CI, 0.87 to 0.99; P=0.038) remained independent predictors for poor outcome at 3 months. Mortality after 3 months was independently associated with Hb nadir (OR=0.80; 95% CI, 0.65 to 0.98; P=0.028) and Hb decrease (OR=1.34; 95% CI, 1.01 to 1.76; P=0.04) as well as Hct decrease (OR=1.12; 95% CI, 1.01 to 1.23; P=0.027). Poor outcome and mortality after ischemic stroke are strongly associated with low and further decreasing Hb and Hct levels. This decrease of Hb and Hct levels after admission might be more relevant and accessible to treatment than are baseline levels.

  7. Autologus normovolemic and hypervolemic hemodilution during surgery using 6% dextran 70 and lactated ringer solution: impact on mean arterial pressure, heart rate, hemoglobin and hematocrite (A preliminary study

    Directory of Open Access Journals (Sweden)

    Ruswan Dachlan

    2006-12-01

    Full Text Available Autologous normovolemic hemodilution (ANH is one of the methods to conserve blood donor (homologous. The decrease in hemoglobin (Hb due to bleeding in major surgery will be minimized and the hematocrite (Hct will be adjusted accordingly by this method. However, due to its impractical clinical application, another simpler hemodilution method is used, i.e. hypervolemic hemodilution (HHD, using 6% dextran 70 and lactated Ringer solutions. The aim of this randomized comparative study was to investigate the impacts of both hemodilution methods (ANH and HHD on mean arterial pressure (MAP, heart rate (HR, hemoglobin (Hb and hematocrite (Hct in anesthetized patients undergoing major surgery. Fourteen (14 women fulfilling the inclusion and exclusion criteria were divided into 2 groups. Seven (7 women received ANH and seven (7 women received HHD method. There were significant statistical differences (P<0.05 between ANH and HHD groups in MAP and Hct after 1 minute (86.3±9.1 vs. 99.1±6.4 on MAP and (27.3±1.7 vs. 31.5±4.4 on Hct and after 20 minutes (87.7±7.3 vs. 98.3±6.8 on MAP and (27.4± 1.7 vs. 3.6±4.8 on Hct post-hemodilution respectively. There was no difference in HR and Hb. No statistical difference between the four parameters tested after 120 minutes post-hemodilution. It may be concluded that both methods worth to be used in clinical setting although further studies are required. (Med J Indones 2006; 15:246-50Keyword: Acute normovolenic hemodilution, acute hypervolemic hemodilution, dextran 70, lactated ringer solution, microsirculation

  8. Point-of-care blood gases, electrolytes, chemistries, hemoglobin, and hematocrit measurement in venous samples from pet rabbits.

    Science.gov (United States)

    Selleri, Paolo; Di Girolamo, Nicola

    2014-01-01

    Point-of-care testing is an attractive option in rabbit medicine, because it permits rapid analysis of a panel of electrolytes, chemistries, blood gases, hemoglobin, and hematocrit, requiring only 65 μL of blood. The purpose of this study was to evaluate the performance of a portable clinical analyzer for measurement of pH, partial pressure of CO2, Na, chloride, potassium, blood urea nitrogen, glucose, hematocrit, and hemoglobin in healthy and diseased rabbits. Blood samples obtained from 30 pet rabbits were analyzed immediately after collection by the portable clinical analyzer (PCA) and immediately thereafter (time <20 sec) by a reference analyzer. Bland-Altman plots and Passing-Bablok regression analysis were used to compare the results. Limits of agreement were wide for all the variables studied, with the exception of pH. Most variables presented significant proportional and/or constant bias. The current study provides sufficient evidence that the PCA presents reliability for pH, although its low agreement with a reference analyzer for the other variables does not support their interchangeability. Limits of agreement provided for each variable allow researchers to evaluate if the PCA is reliable enough for their scope. To the authors' knowledge, the present is the first report evaluating a PCA in the rabbit.

  9. Point-of-Care Versus Central Laboratory Measurements of Hemoglobin, Hematocrit, Glucose, Bicarbonate and Electrolytes: A Prospective Observational Study in Critically Ill Patients.

    Directory of Open Access Journals (Sweden)

    Jérôme Allardet-Servent

    Full Text Available Rapid detection of abnormal biological values using point-of-care (POC testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose.314 paired samples were collected prospectively from 51 critically ill patients. All samples were drawn simultaneously in the morning from an arterial line. BD Vacutainer tubes were analyzed in the central laboratory using Beckman Coulter analyzers (AU 5800 and DxH 800. BD Preset 3 ml heparinized-syringes were analyzed immediately in the ICU using the POC Siemens RAPIDPoint 500 blood gas system. We used CLIA proficiency testing criteria to define acceptable analytical performance and interchangeability.Biases, limits of agreement (±1.96 SD and coefficients of correlation were respectively: 1.3 (-2.2 to 4.8 mmol/L, r = 0.936 for sodium; 0.2 (-0.2 to 0.6 mmol/L, r = 0.944 for potassium; -0.9 (-3.7 to 2 mmol/L, r = 0.967 for chloride; 0.8 (-1.9 to 3.4 mmol/L, r = 0.968 for bicarbonate; -11 (-30 to 9 mg/dL, r = 0.972 for glucose; -0.8 (-1.4 to -0.2 g/dL, r = 0.985 for hemoglobin; and -1.1 (-2.9 to 0.7%, r = 0.981 for hematocrit. All differences were below CLIA cut-off values, except for hemoglobin.Compared to central Laboratory analyzers, the POC Siemens RAPIDPoint 500 blood gas system satisfied the CLIA criteria of interchangeability for all tested parameters, except for hemoglobin. These results are warranted for our own procedures and devices. Bearing these restrictions, we recommend clinicians to initiate an appropriate therapy based on POC testing without awaiting a control measurement.

  10. Point-of-Care Versus Central Laboratory Measurements of Hemoglobin, Hematocrit, Glucose, Bicarbonate and Electrolytes: A Prospective Observational Study in Critically Ill Patients.

    Science.gov (United States)

    Allardet-Servent, Jérôme; Lebsir, Melissa; Dubroca, Christian; Fabrigoule, Martine; Jordana, Sylvie; Signouret, Thomas; Castanier, Matthias; Thomas, Guillemette; Soundaravelou, Rettinavelou; Lepidi, Anne; Delapierre, Laurence; Penaranda, Guillaume; Halfon, Philippe; Seghboyan, Jean-Marie

    2017-01-01

    Rapid detection of abnormal biological values using point-of-care (POC) testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose. 314 paired samples were collected prospectively from 51 critically ill patients. All samples were drawn simultaneously in the morning from an arterial line. BD Vacutainer tubes were analyzed in the central laboratory using Beckman Coulter analyzers (AU 5800 and DxH 800). BD Preset 3 ml heparinized-syringes were analyzed immediately in the ICU using the POC Siemens RAPIDPoint 500 blood gas system. We used CLIA proficiency testing criteria to define acceptable analytical performance and interchangeability. Biases, limits of agreement (±1.96 SD) and coefficients of correlation were respectively: 1.3 (-2.2 to 4.8 mmol/L, r = 0.936) for sodium; 0.2 (-0.2 to 0.6 mmol/L, r = 0.944) for potassium; -0.9 (-3.7 to 2 mmol/L, r = 0.967) for chloride; 0.8 (-1.9 to 3.4 mmol/L, r = 0.968) for bicarbonate; -11 (-30 to 9 mg/dL, r = 0.972) for glucose; -0.8 (-1.4 to -0.2 g/dL, r = 0.985) for hemoglobin; and -1.1 (-2.9 to 0.7%, r = 0.981) for hematocrit. All differences were below CLIA cut-off values, except for hemoglobin. Compared to central Laboratory analyzers, the POC Siemens RAPIDPoint 500 blood gas system satisfied the CLIA criteria of interchangeability for all tested parameters, except for hemoglobin. These results are warranted for our own procedures and devices. Bearing these restrictions, we recommend clinicians to initiate an appropriate therapy based on POC testing without awaiting a control measurement.

  11. Remote detection device and detection method therefor

    International Nuclear Information System (INIS)

    Kogure, Sumio; Yoshida, Yoji; Matsuo, Takashiro; Takehara, Hidetoshi; Kojima, Shinsaku.

    1997-01-01

    The present invention provides a non-destructive detection device for collectively, efficiently and effectively conducting maintenance and detection for confirming the integrity of a nuclear reactor by way of a shielding member for shielding radiation rays generated from an objective portion to be detected. Namely, devices for direct visual detection using an under water TV camera as a sensor, an eddy current detection using a coil as a sensor and each magnetic powder flow detection are integrated and applied collectively. Specifically, the visual detection by using the TV camera and the eddy current flaw detection are adopted together. The flaw detection with magnetic powder is applied as a means for confirming the results of the two kinds of detections by other method. With such procedures, detection techniques using respective specific theories are combined thereby enabling to enhance the accuracy for the evaluation of the detection. (I.S.)

  12. Real-time electrical impedimetric monitoring of blood coagulation process under temperature and hematocrit variations conducted in a microfluidic chip.

    Directory of Open Access Journals (Sweden)

    Kin Fong Lei

    Full Text Available Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity.

  13. Mass Spectrometry Method to Measure Membrane Proteins in Dried Blood Spots for the Detection of Blood Doping Practices in Sport.

    Science.gov (United States)

    Cox, Holly D; Eichner, Daniel

    2017-09-19

    The dried blood spot (DBS) matrix has significant utility for applications in the field where venous blood collection and timely shipment of labile blood samples is difficult. Unfortunately, protein measurement in DBS is hindered by high abundance proteins and matrix interference that increases with hematocrit. We developed a DBS method to enrich for membrane proteins and remove soluble proteins and matrix interference. Following a wash in a series of buffers, the membrane proteins are digested with trypsin and quantitated by parallel reaction monitoring mass spectrometry methods. The DBS method was applied to the quantification of four cell-specific cluster of differentiation (CD) proteins used to count cells by flow cytometry, band 3 (CD233), CD71, CD45, and CD41. We demonstrate that the DBS method counts low abundance cell types such as immature reticulocytes as well as high abundance cell types such as red blood cells, white blood cells, and platelets. When tested in 82 individuals, counts obtained by the DBS method demonstrated good agreement with flow cytometry and automated hematology analyzers. Importantly, the method allows longitudinal monitoring of CD protein concentration and calculation of interindividual variation which is difficult by other methods. Interindividual variation of band 3 and CD45 was low, 6 and 8%, respectively, while variation of CD41 and CD71 was higher, 18 and 78%, respectively. Longitudinal measurement of CD71 concentration in DBS over an 8-week period demonstrated intraindividual variation 17.1-38.7%. Thus, the method may allow stable longitudinal measurement of blood parameters currently monitored to detect blood doping practices.

  14. Doppler method leak detection for LMFBR steam generators. Pt. 3. Investigation of detection sensitivity and method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kinoshita, Izumi

    2001-01-01

    To prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of a fast breeder reactor (FBR), it is necessary to detect precisely and immediately any leakage of water from heat transfer tubes. Therefore, the Doppler method was developed. Previous studies have revealed that, in the SG full-sector model that simulates actual SGs, the Doppler method can detect bubbles of 0.4 l/s within a few seconds. However in consideration of the dissolution rate of hydrogen generated by a sodium-water reaction even from a small water leak, it is necessary to detect smaller leakages of water from the heat transfer tubes. The detection sensitivity of the Doppler method and the influence of background noise were experimentally investigated. In-water experiments were performed using the SG model. The results show that the Doppler method can detect bubbles of 0.01 l/s (equivalent to a water leak rate of about 0.01 g/s) within a few seconds and that the background noise has little effect on water leak detection performance. The Doppler method thus has great potential for the detection of water leakage in SGs. (author)

  15. Comparison of Methods for Oscillation Detection

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Trangbæk, Klaus

    2006-01-01

    This paper compares a selection of methods for detecting oscillations in control loops. The methods are tested on measurement data from a coal-fired power plant, where some oscillations are occurring. Emphasis is put on being able to detect oscillations without having a system model and without...... using process knowledge. The tested methods show potential for detecting the oscillations, however, transient components in the signals cause false detections as well, motivating usage of models in order to remove the expected signals behavior....

  16. A Voltage Quality Detection Method

    DEFF Research Database (Denmark)

    Chen, Zhe; Wei, Mu

    2008-01-01

    This paper presents a voltage quality detection method based on a phase-locked loop (PLL) technique. The technique can detect the voltage magnitude and phase angle of each individual phase under both normal and fault power system conditions. The proposed method has the potential to evaluate various...

  17. Leak detection by vibrational diagnostic methods

    International Nuclear Information System (INIS)

    Siklossy, P.

    1983-01-01

    The possibilities and methods of leak detection due to mechanical failures in nuclear power plants are reviewed on the basis of the literature. Great importance is attributed to vibrational diagnostic methods for their adventageous characteristics which enable them to become final leak detecting methods. The problems of noise analysis, e.g. leak detection by impact sound measurements, probe characteristics, gain problems, probe selection, off-line analysis and correlation functions, types of leak noises etc. are summarized. Leak detection based on noise analysis can be installed additionally to power plants. Its maintenance and testing is simple. On the other hand, it requires special training and measuring methods. (Sz.J.)

  18. Margination of Fluorescent Polylactic Acid–Polyaspartamide based Nanoparticles in Microcapillaries In Vitro: the Effect of Hematocrit and Pressure

    Directory of Open Access Journals (Sweden)

    Emanuela Fabiola Craparo

    2017-10-01

    Full Text Available The last decade has seen the emergence of vascular-targeted drug delivery systems as a promising approach for the treatment of many diseases, such as cardiovascular diseases and cancer. In this field, one of the major challenges is carrier margination propensity (i.e., particle migration from blood flow to vessel walls; indeed, binding of these particles to targeted cells and tissues is only possible if there is direct carrier–wall interaction. Here, a microfluidic system mimicking the hydrodynamic conditions of human microcirculation in vitro is used to investigate the effect of red blood cells (RBCs on a carrier margination in relation to RBC concentration (hematocrit and pressure drop. As model drug carriers, fluorescent polymeric nanoparticles (FNPs were chosen, which were obtained by using as starting material a pegylated polylactic acid–polyaspartamide copolymer. The latter was synthesized by derivatization of α,β-poly(N-2-hydroxyethyl-d,l-aspartamide (PHEA with Rhodamine (RhB, polylactic acid (PLA and then poly(ethyleneglycol (PEG chains. It was found that the carrier concentration near the wall increases with increasing pressure drop, independently of RBC concentration, and that the tendency for FNP margination decreases with increasing hematocrit. This work highlights the importance of taking into account RBC–drug carrier interactions and physiological conditions in microcirculation when planning a drug delivery strategy based on systemically administered carriers.

  19. A comparison of moving object detection methods for real-time moving object detection

    Science.gov (United States)

    Roshan, Aditya; Zhang, Yun

    2014-06-01

    Moving object detection has a wide variety of applications from traffic monitoring, site monitoring, automatic theft identification, face detection to military surveillance. Many methods have been developed across the globe for moving object detection, but it is very difficult to find one which can work globally in all situations and with different types of videos. The purpose of this paper is to evaluate existing moving object detection methods which can be implemented in software on a desktop or laptop, for real time object detection. There are several moving object detection methods noted in the literature, but few of them are suitable for real time moving object detection. Most of the methods which provide for real time movement are further limited by the number of objects and the scene complexity. This paper evaluates the four most commonly used moving object detection methods as background subtraction technique, Gaussian mixture model, wavelet based and optical flow based methods. The work is based on evaluation of these four moving object detection methods using two (2) different sets of cameras and two (2) different scenes. The moving object detection methods have been implemented using MatLab and results are compared based on completeness of detected objects, noise, light change sensitivity, processing time etc. After comparison, it is observed that optical flow based method took least processing time and successfully detected boundary of moving objects which also implies that it can be implemented for real-time moving object detection.

  20. Rapid methods for detection of bacteria

    DEFF Research Database (Denmark)

    Corfitzen, Charlotte B.; Andersen, B.Ø.; Miller, M.

    2006-01-01

    Traditional methods for detection of bacteria in drinking water e.g. Heterotrophic Plate Counts (HPC) or Most Probable Number (MNP) take 48-72 hours to give the result. New rapid methods for detection of bacteria are needed to protect the consumers against contaminations. Two rapid methods...

  1. Comparison of point-of-care versus central laboratory measurement of hematocrit, hemoglobin, and electrolyte concentrations.

    Science.gov (United States)

    Gavala, Alexandra; Myrianthefs, Pavlos

    We aimed to investigate the accuracy of certain laboratory examinations obtained by the ABG analyzer (ROCHE AVL OMNI S) as compared to hospital central laboratory (CL). We prospectively collected data obtained from the same arterial blood sample regarding hematocrit, hemoglobin, potassium, and sodium. ABG analyzer results were significantly lower (p < 0.0001) compared to CL values thus values between the two methods are not interchangeable. The mean bias for Hb, Na + and K + were within accepted by US Clinical Laboratory Improvement Amendment (USCLIA) differences (cut-off points) but not for Ht. In 8.0%, 17.5%, 37.5% and 56.0% of Hb, Na + , K + and Ht measurements respectively and 29.75% in sum the differences were over the USCLIA accepted limits. ABG analyzer significantly underestimate the values of Hb, Ht, Na + and K + , compared to CL and almost 30% of all examined parameters were beyond USCLIA accepted biases. ABG analyzer significantly underestimates the values of Hb, Ht, Na + and K + compared to CL and almost 30% for all examined parameters are beyond USCLIA accepted biases. These data do not support widespread or even careful use of POCT for making diagnostic and treatment decisions until technology improves and results in improved outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Hematocrit and Hemoglobin Levels of Nonhuman Apes at Moderate Altitudes: A Comparison with Humans.

    Science.gov (United States)

    Mortola, Jacopo P; Wilfong, DeeAnn

    2016-12-01

    Mortola, Jacopo P. and DeeAnn Wilfong. Hematocrit and hemoglobin levels of nonhuman apes at moderate altitudes: a comparison with humans. High Alt Med Biol. 17:323-335, 2016.-We asked to what extent the hematologic response (increase in hematocrit [Hct] and in blood hemoglobin concentration [Hb]) of humans to altitude hypoxia was shared by our closest relatives, the nonhuman apes. Data were collected from 29 specimens of 7 species of apes at 2073 m altitude (barometric pressure Pb = 598 mm Hg); additional data originated from apes located at a lower altitude (1493 m, Pb = 639 mm Hg). The human altitude profiles of Hct and Hb between sea level and 3000 m were constructed from a compilation of literature sources that (all combined) comprised data sets of 10,000-12,000 subjects for each gender. These human data were binned for 0-250 m altitude (sea level) and for each 500 m of progressively higher altitudes. Values of Hb and Hct of both men and women were significantly higher than at sea level at the 1500 bin (1250-1750 m); hence, the altitude threshold for the human hematological responses must be between 1000 and 1500 m. In the nonhuman apes, no increase in Hct or Hb was apparent at 1500 m; at 2000 m, the increase was significant only for the Hb of females. At either altitude in the group of nonhuman apes, the increase in Hct was much less than in humans, and that of Hb was significantly less at 1500 m. We conclude that lack of, or minimal, hematopoietic response to moderate altitude can occur in mammalian species that are not genetically adapted to high altitudes. Polycythemia is not a common response to altitude hypoxia and, at least at moderate altitudes, the degree of the human response may represent the exception among apes rather than the rule.

  3. Detection of oral HPV infection - Comparison of two different specimen collection methods and two HPV detection methods.

    Science.gov (United States)

    de Souza, Marjorie M A; Hartel, Gunter; Whiteman, David C; Antonsson, Annika

    2018-04-01

    Very little is known about the natural history of oral HPV infection. Several different methods exist to collect oral specimens and detect HPV, but their respective performance characteristics are unknown. We compared two different methods for oral specimen collection (oral saline rinse and commercial saliva kit) from 96 individuals and then analyzed the samples for HPV by two different PCR detection methods (single GP5+/6+ PCR and nested MY09/11 and GP5+/6+ PCR). For the oral rinse samples, the oral HPV prevalence was 10.4% (GP+ PCR; 10% repeatability) vs 11.5% (nested PCR method; 100% repeatability). For the commercial saliva kit samples, the prevalences were 3.1% vs 16.7% with the GP+ PCR vs the nested PCR method (repeatability 100% for both detection methods). Overall the agreement was fair or poor between samples and methods (kappa 0.06-0.36). Standardizing methods of oral sample collection and HPV detection would ensure comparability between future oral HPV studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Some methods for the detection of fissionable matter; Quelques methodes de detection des corps fissiles

    Energy Technology Data Exchange (ETDEWEB)

    Guery, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-03-01

    A number of equipments or processes allowing to detect uranium or plutonium in industrial plants, and in particular to measure solution concentrations, are studied here. Each method has its own field of applications and has its own performances, which we have tried to define by calculations and by experiments. The following topics have been treated: {gamma} absorptiometer with an Am source, detection test by neutron multiplication, apparatus for the measurement of the {alpha} activity of a solution, fissionable matter detection by {gamma} emission, fissionable matter detection by neutron emission. (author) [French] On examine ici plusieurs appareils ou procedes qui permettent de detecter l'uranium ou le plutonium dans les installations industrielles, et en particulier de mesurer les concentrations de solutions. Chacune des methodes a son domaine d'application et ses performances, qu'on a tente de definir par le calcul et par des experiences. Les sujets traites sont les suivants: absorptiometre {gamma} a source d'americium, essais de detection par multiplication neutronique, appareil de mesure de l'activite {alpha} d'une solution, detection des matieres fissiles par leur emission {gamma}, detection des matieres fissiles par leur emission neutronique. (auteur)

  5. An Entropy-Based Network Anomaly Detection Method

    Directory of Open Access Journals (Sweden)

    Przemysław Bereziński

    2015-04-01

    Full Text Available Data mining is an interdisciplinary subfield of computer science involving methods at the intersection of artificial intelligence, machine learning and statistics. One of the data mining tasks is anomaly detection which is the analysis of large quantities of data to identify items, events or observations which do not conform to an expected pattern. Anomaly detection is applicable in a variety of domains, e.g., fraud detection, fault detection, system health monitoring but this article focuses on application of anomaly detection in the field of network intrusion detection.The main goal of the article is to prove that an entropy-based approach is suitable to detect modern botnet-like malware based on anomalous patterns in network. This aim is achieved by realization of the following points: (i preparation of a concept of original entropy-based network anomaly detection method, (ii implementation of the method, (iii preparation of original dataset, (iv evaluation of the method.

  6. GMDD: a database of GMO detection methods.

    Science.gov (United States)

    Dong, Wei; Yang, Litao; Shen, Kailin; Kim, Banghyun; Kleter, Gijs A; Marvin, Hans J P; Guo, Rong; Liang, Wanqi; Zhang, Dabing

    2008-06-04

    Since more than one hundred events of genetically modified organisms (GMOs) have been developed and approved for commercialization in global area, the GMO analysis methods are essential for the enforcement of GMO labelling regulations. Protein and nucleic acid-based detection techniques have been developed and utilized for GMOs identification and quantification. However, the information for harmonization and standardization of GMO analysis methods at global level is needed. GMO Detection method Database (GMDD) has collected almost all the previous developed and reported GMOs detection methods, which have been grouped by different strategies (screen-, gene-, construct-, and event-specific), and also provide a user-friendly search service of the detection methods by GMO event name, exogenous gene, or protein information, etc. In this database, users can obtain the sequences of exogenous integration, which will facilitate PCR primers and probes design. Also the information on endogenous genes, certified reference materials, reference molecules, and the validation status of developed methods is included in this database. Furthermore, registered users can also submit new detection methods and sequences to this database, and the newly submitted information will be released soon after being checked. GMDD contains comprehensive information of GMO detection methods. The database will make the GMOs analysis much easier.

  7. Evaluation of the effect of hemoglobin or hematocrit level on dural sinus density using unenhanced computed tomography.

    Science.gov (United States)

    Lee, Seung Young; Cha, Sang-Hoon; Lee, Sung-Hyun; Shin, Dong-Ick

    2013-01-01

    To identify the relationship between hemoglobin (Hgb) or hematocrit (Hct) level and dural sinus density using unenhanced computed tomography (UECT). Patients who were performed UECT and had records of a complete blood count within 24 hours from UECT were included (n=122). We measured the Hounsfield unit (HU) of the dural sinus at the right sigmoid sinus, left sigmoid sinus and 2 points of the superior sagittal sinus. Quantitative measurement of dural sinus density using the circle regions of interest (ROI) method was calculated as average ROI values at 3 or 4 points. Simple regression analysis was used to evaluate the correlation between mean HU and Hgb or mean HU and Hct. The mean densities of the dural sinuses ranged from 24.67 to 53.67 HU (mean, 43.28 HU). There was a strong correlation between mean density and Hgb level (r=0.832) and between mean density and Hct level (r=0.840). Dural sinus density on UECT is closely related to Hgb and Hct levels. Therefore, the Hgb or Hct levels can be used to determine whether the dural sinus density is within the normal range or pathological conditions such as venous thrombosis.

  8. A new fault detection method for computer networks

    International Nuclear Information System (INIS)

    Lu, Lu; Xu, Zhengguo; Wang, Wenhai; Sun, Youxian

    2013-01-01

    Over the past few years, fault detection for computer networks has attracted extensive attentions for its importance in network management. Most existing fault detection methods are based on active probing techniques which can detect the occurrence of faults fast and precisely. But these methods suffer from the limitation of traffic overhead, especially in large scale networks. To relieve traffic overhead induced by active probing based methods, a new fault detection method, whose key is to divide the detection process into multiple stages, is proposed in this paper. During each stage, only a small region of the network is detected by using a small set of probes. Meanwhile, it also ensures that the entire network can be covered after multiple detection stages. This method can guarantee that the traffic used by probes during each detection stage is small sufficiently so that the network can operate without severe disturbance from probes. Several simulation results verify the effectiveness of the proposed method

  9. Leak detection method

    International Nuclear Information System (INIS)

    1978-01-01

    This invention provides a method for removing nuclear fuel elements from a fabrication building while at the same time testing the fuel elements for leaks without releasing contaminants from the fabrication building or from the fuel elements. The vacuum source used, leak detecting mechanism and fuel element fabrication building are specified to withstand environmental hazards. (UK)

  10. An Instantaneous Low-Cost Point-of-Care Anemia Detection Device

    Directory of Open Access Journals (Sweden)

    Jaime Punter-Villagrasa

    2015-02-01

    Full Text Available We present a small, compact and portable device for point-of-care instantaneous early detection of anemia. The method used is based on direct hematocrit measurement from whole blood samples by means of impedance analysis. This device consists of a custom electronic instrumentation and a plug-and-play disposable sensor. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low consumption device making it completely mobile with a long battery life. Another approach could be powering the system based on other solutions like indoor solar cells, or applying energy-harvesting solutions in order to remove the batteries. The sensing system is based on a disposable low-cost label-free three gold electrode commercial sensor for 50 µL blood samples. The device capability for anemia detection has been validated through 24 blood samples, obtained from four hospitalized patients at Hospital Clínic. As a result, the response, effectiveness and robustness of the portable point-of-care device to detect anemia has been proved with an accuracy error of 2.83% and a mean coefficient of variation of 2.57% without any particular case above 5%.

  11. Hematocrit levels as cardiovascular risk among taxi drivers in Bangkok, Thailand

    Science.gov (United States)

    ISHIMARU, Tomohiro; ARPHORN, Sara; JIRAPONGSUWAN, Ann

    2016-01-01

    In Thailand, taxi drivers employed in the informal sector often experience hazardous working conditions. Previous studies revealed that elevated Hematocrit (HCT) is a predictor of cardiovascular disease (CVD) risk. This study assessed factors associated with HCT in taxi drivers to predict their occupational CVD risk factors. A cross-sectional study was conducted on 298 male taxi drivers who joined a health check-up campaign in Bangkok, Thailand. HCT and body mass index were retrieved from participant health check-up files. Self-administered questionnaires assessed demographics, driving mileage, working hours, and lifestyle. Statistical associations were analyzed using stepwise linear regression. Our results showed that obesity (p=0.007), daily alcohol drinking (p=0.003), and current or past smoking (p=0.016) were associated with higher HCT levels. While working hours were not directly associated with HCT levels in the current study, the effect on overworking is statistically arguable because most participants worked substantially longer hours. Our findings suggest that taxi drivers’ CVD risk may be increased by their unhealthy work styles. Initiatives to improve general working conditions for taxi drivers should take into account health promotion and CVD prevention. The policy of providing periodic health check-ups is important to make workers in the informal sector aware of their health status. PMID:27151439

  12. Respons of Erythrocytes, Hematocrit and Hemoglobin River Catfish (Mystus Nemurus) Combination Fed Guava Leaves (Psidium Guajava) and Bitter (Andrographis Paniculata Ness)

    OpenAIRE

    Susanti, Mesi; Lukystiowati, Iesje; Syawal, Henni

    2014-01-01

    This study was conducted from April-June 2013 in the Laboratory of Aquaculture and Fish Diseases and Parasites Laboratory Faculty of Fisheries and Marine Sciences University of Riau. The purpose of this study was to determine the response of erythrocytes, hematocrit, and blood hemoglobin river catfish (Mystus nemurus) fed a combination of guava leaves and bitter infected with the bacterium A. hydrophila. This study used 5 treatments of: negative control (without any solution guava, bitter and...

  13. Blood Density Is Nearly Equal to Water Density: A Validation Study of the Gravimetric Method of Measuring Intraoperative Blood Loss.

    Science.gov (United States)

    Vitello, Dominic J; Ripper, Richard M; Fettiplace, Michael R; Weinberg, Guy L; Vitello, Joseph M

    2015-01-01

    Purpose. The gravimetric method of weighing surgical sponges is used to quantify intraoperative blood loss. The dry mass minus the wet mass of the gauze equals the volume of blood lost. This method assumes that the density of blood is equivalent to water (1 gm/mL). This study's purpose was to validate the assumption that the density of blood is equivalent to water and to correlate density with hematocrit. Methods. 50 µL of whole blood was weighed from eighteen rats. A distilled water control was weighed for each blood sample. The averages of the blood and water were compared utilizing a Student's unpaired, one-tailed t-test. The masses of the blood samples and the hematocrits were compared using a linear regression. Results. The average mass of the eighteen blood samples was 0.0489 g and that of the distilled water controls was 0.0492 g. The t-test showed P = 0.2269 and R (2) = 0.03154. The hematocrit values ranged from 24% to 48%. The linear regression R (2) value was 0.1767. Conclusions. The R (2) value comparing the blood and distilled water masses suggests high correlation between the two populations. Linear regression showed the hematocrit was not proportional to the mass of the blood. The study confirmed that the measured density of blood is similar to water.

  14. Detection methods of irradiated foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Ponta, C C; Cutrubinis, M; Georgescu, R [IRASM Center, Horia Hulubei National Institute for Physics and Nuclear Engineering, PO Box MG-6, RO-077125 Magurele-Bucharest (Romania); Mihai, R [Life and Environmental Physics Department, Horia Hulubei National Institute for Physics and Nuclear Engineering, PO Box MG-6, RO-077125 Magurele-Bucharest (Romania); Secu, M [National Institute of Materials Physics, Bucharest (Romania)

    2005-07-01

    food is marketed as irradiated or if irradiated goods are sold without the appropriate labeling, then detection tests should be able to prove the authenticity of the product. For the moment in Romania there is not any food control laboratory able to detect irradiated foodstuffs. The Technological Irradiation Department coordinates and co finances a research project aimed to establish the first Laboratory of Irradiated Foodstuffs Detection. The detection methods studied in this project are the ESR methods (for cellulose EN 1787/2000, bone EN 1786/1996 and crystalline sugar EN 13708/2003), the TL method (EN 1788/2001), the PSL method (EN 13751/2002) and the DNA Comet Assay method (EN 13784/2001). The above detection methods will be applied on various foodstuffs such: garlic, onion, potatoes, rice, beans, wheat, maize, pistachio, sunflower seeds, raisins, figs, strawberries, chicken, beef, fish, pepper, paprika, thyme, laurel and mushrooms. As an example of the application of a detection method there are presented the ESR spectra of irradiated and nonirradiated paprika acquired according to ESR detection method for irradiated foodstuffs containing cellulose. First of all it can be noticed that the intensity of the signal of cellulose is much higher for the irradiated sample than that for the nonirradiated one and second that appear two radiation specific signals symmetrical to the cellulose signal. These two radiation specific signals prove the irradiation treatment of paprika. (author)

  15. Spices, irradiation and detection methods

    International Nuclear Information System (INIS)

    Sjoeberg, A.M.; Manninen, M.

    1991-01-01

    This paper is about microbiological aspects of spices and microbiological methods to detect irradiated food. The proposed method is a combination of the Direct Epifluorescence Filter Technique (DEFT) and the Aerobic Plate Count (APC). The evidence for irradiation of spices is based on the demonstration of a higher DEFT count than the APC. The principle was first tested in our earlier investigation in the detection of irradiation of whole spices. The combined DEFT+APC procedure was found to give a fairly reliable indication of whether or not a whole spice sample had been irradiated. The results are given (8 figs, 22 refs)

  16. Uso da Técnica do Micro-Hematócrito para Predição do Peso Corporal e de Características Reprodutivas em Frangos de Corte Utilization of Micro-Hematocrit Technique on Body Weight and Reproductive Traits Prediction in Broiler Chickens

    Directory of Open Access Journals (Sweden)

    Millor Fernandes do Rosário

    2002-06-01

    Full Text Available O hematócrito é uma metodologia indireta utilizada no monitoramento da síndrome ascítica que poderia ser utilizada também para avaliar o peso corporal e características reprodutivas em frangos de corte. Objetivou-se com este trabalho avaliar a técnica do micro-hematócrito em relação ao peso corporal e características reprodutivas (fertilidade, eclodibilidade e nascimento visando sua utilização pelos programas de melhoramento genético. Dois grupos contrastantes foram constituídos, baseados na seleção fenotípica de 630 reprodutores de 18 genótipos para a característica hematócrito. Progênies das aves selecionadas, 74 pintos não sexados (40 do grupo de hematócrito alto e 34 do grupo baixo foram criados com manejo convencional. Os pesos corporais e os valores de hematócrito foram mensurados aos 14 e 42 dias de idade. Para avaliar as características reprodutivas, ovos de 42 matrizes (22 do grupo alto e 20 do baixo foram incubados. As médias foram estimadas utilizando-se um modelo linear com o efeito fixo do grupo genético. Os pintos do grupo baixo apresentaram as maiores médias de peso corporal (305,59 e 1387,06 g, diferindo dos pintos do grupo alto os quais apresentaram médias de peso de 243,56 e 1128,11 g aos 14 e 42 dias de idade, respectivamente. Também para o valor do hematócrito os grupos diferiram significativamente. Para as características reprodutivas, não se verificou diferenças significativas entre os grupos, sendo as médias gerais para fertilidade de 93,8 e 94,9%, para eclodibilidade de 98,2 e 93,9% e para nascimento de 89,3 e 82,4%, respectivamente, para alto e baixo hematócrito. Concluiu-se que a técnica do micro-hematócrito pode ser empregada para avaliação do peso corporal, mas não para características reprodutivas.Hematocrit is an indirect method used to monitor ascites, which might be used also on body weight and reproductive traits evalution in broiler chickens. The aim of this paper was

  17. Use of kidney impressions for the detection of trypanosomes of anura.

    Science.gov (United States)

    Jones, S R; Woo, P T

    1989-07-01

    The sensitivities of three techniques used for detecting infections of Trypanosoma spp. in frogs (Rana spp.) were compared. In total, 52 of 99 frogs had detectable infections of T. rotatorium, T. chattoni, T. pipientis or T. ranarum. Two or more Trypanosoma spp. were detected in 12 frogs. Microscopic examination of stained kidney impressions (KIT) was more sensitive than either hematocrit centrifugation (HCT) or wet-mount examination (WME) in detecting T. rotatorium and T. chattoni. The HCT was more sensitive in detecting T. pipientis and T. ranarum. Four infections of T. rotatorium that were missed using the HCT were detected using the WME; one of these was missed using the KIT. Success of the KIT may be related to size of the trypanosome while success of the HCT may be related to size, motility or specific gravity of the trypanosome.

  18. Improved GLR method to instrument failure detection

    International Nuclear Information System (INIS)

    Jeong, Hak Yeoung; Chang, Soon Heung

    1985-01-01

    The generalized likehood radio(GLR) method performs statistical tests on the innovations sequence of a Kalman-Buchy filter state estimator for system failure detection and its identification. However, the major drawback of the convensional GLR is to hypothesize particular failure type in each case. In this paper, a method to solve this drawback is proposed. The improved GLR method is applied to a PWR pressurizer and gives successful results in detection and identification of any failure. Furthmore, some benefit on the processing time per each cycle of failure detection and its identification can be accompanied. (Author)

  19. Thermoelectric SQUID method for the detection of segregations

    Science.gov (United States)

    Hinken, Johann H.; Tavrin, Yury

    2000-05-01

    Aero engine turbine discs are most critical parts. Material inhomogeneities can cause disc fractures during the flight with fatal air disasters. Nondestructive testing (NDT) of the discs in various machining steps is necessary and performed as well as possible. Conventional NDT methods, however, like eddy current testing and ultrasonic testing have unacceptable limits. For example, subsurface segregations often cannot be detected directly but only indirectly in such cases when cracks already have developed from them. This may be too late. A new NDT method, which we call the Thermoelectric SQUID Method, has been developed. It allows for the detection of metallic inclusions within non-ferromagnetic metallic base material. This paper describes the results of a feasibility study on aero engine turbine discs made from Inconel® 718. These contained segregations that had been detected before by anodic etching. With the Thermoelectric SQUID Method, these segregations were detected again, and further segregations below the surfaces have been found, which had not been detected before. For this new NDT method the disc material is quasi-transparent. The Thermoelectric SQUID Method is also useful to detect distributed and localized inhomogeneities in pure metals like niobium sheets for particle accelerators.

  20. Distance Measurement Methods for Improved Insider Threat Detection

    Directory of Open Access Journals (Sweden)

    Owen Lo

    2018-01-01

    Full Text Available Insider threats are a considerable problem within cyber security and it is often difficult to detect these threats using signature detection. Increasing machine learning can provide a solution, but these methods often fail to take into account changes of behaviour of users. This work builds on a published method of detecting insider threats and applies Hidden Markov method on a CERT data set (CERT r4.2 and analyses a number of distance vector methods (Damerau–Levenshtein Distance, Cosine Distance, and Jaccard Distance in order to detect changes of behaviour, which are shown to have success in determining different insider threats.

  1. Comparative analysis of methods for detecting interacting loci.

    Science.gov (United States)

    Chen, Li; Yu, Guoqiang; Langefeld, Carl D; Miller, David J; Guy, Richard T; Raghuram, Jayaram; Yuan, Xiguo; Herrington, David M; Wang, Yue

    2011-07-05

    Interactions among genetic loci are believed to play an important role in disease risk. While many methods have been proposed for detecting such interactions, their relative performance remains largely unclear, mainly because different data sources, detection performance criteria, and experimental protocols were used in the papers introducing these methods and in subsequent studies. Moreover, there have been very few studies strictly focused on comparison of existing methods. Given the importance of detecting gene-gene and gene-environment interactions, a rigorous, comprehensive comparison of performance and limitations of available interaction detection methods is warranted. We report a comparison of eight representative methods, of which seven were specifically designed to detect interactions among single nucleotide polymorphisms (SNPs), with the last a popular main-effect testing method used as a baseline for performance evaluation. The selected methods, multifactor dimensionality reduction (MDR), full interaction model (FIM), information gain (IG), Bayesian epistasis association mapping (BEAM), SNP harvester (SH), maximum entropy conditional probability modeling (MECPM), logistic regression with an interaction term (LRIT), and logistic regression (LR) were compared on a large number of simulated data sets, each, consistent with complex disease models, embedding multiple sets of interacting SNPs, under different interaction models. The assessment criteria included several relevant detection power measures, family-wise type I error rate, and computational complexity. There are several important results from this study. First, while some SNPs in interactions with strong effects are successfully detected, most of the methods miss many interacting SNPs at an acceptable rate of false positives. In this study, the best-performing method was MECPM. Second, the statistical significance assessment criteria, used by some of the methods to control the type I error rate

  2. Comparative analysis of methods for detecting interacting loci

    Directory of Open Access Journals (Sweden)

    Yuan Xiguo

    2011-07-01

    Full Text Available Abstract Background Interactions among genetic loci are believed to play an important role in disease risk. While many methods have been proposed for detecting such interactions, their relative performance remains largely unclear, mainly because different data sources, detection performance criteria, and experimental protocols were used in the papers introducing these methods and in subsequent studies. Moreover, there have been very few studies strictly focused on comparison of existing methods. Given the importance of detecting gene-gene and gene-environment interactions, a rigorous, comprehensive comparison of performance and limitations of available interaction detection methods is warranted. Results We report a comparison of eight representative methods, of which seven were specifically designed to detect interactions among single nucleotide polymorphisms (SNPs, with the last a popular main-effect testing method used as a baseline for performance evaluation. The selected methods, multifactor dimensionality reduction (MDR, full interaction model (FIM, information gain (IG, Bayesian epistasis association mapping (BEAM, SNP harvester (SH, maximum entropy conditional probability modeling (MECPM, logistic regression with an interaction term (LRIT, and logistic regression (LR were compared on a large number of simulated data sets, each, consistent with complex disease models, embedding multiple sets of interacting SNPs, under different interaction models. The assessment criteria included several relevant detection power measures, family-wise type I error rate, and computational complexity. There are several important results from this study. First, while some SNPs in interactions with strong effects are successfully detected, most of the methods miss many interacting SNPs at an acceptable rate of false positives. In this study, the best-performing method was MECPM. Second, the statistical significance assessment criteria, used by some of the

  3. Neurocognitive profiles of preterm infants randomly assigned to lower or higher hematocrit thresholds for transfusion.

    Science.gov (United States)

    McCoy, Thomasin E; Conrad, Amy L; Richman, Lynn C; Lindgren, Scott D; Nopoulos, Peg C; Bell, Edward F

    2011-01-01

    Preterm infants are frequently transfused with red blood cells based on standardized guidelines or clinical concerns that anemia taxes infants' physiological compensatory mechanisms and thereby threatens their health and well-being. The impact of various transfusion guidelines on long-term neurocognitive outcome is not known. The purpose of this study is to evaluate long-term neurocognitive outcome on children born prematurely and treated at birth with different transfusion guidelines. Neurocognitive outcomes were examined at school age for 56 preterm infants randomly assigned to a liberal (n = 33) or restrictive (n = 23) transfusion strategy. Tests of intelligence, achievement, language, visual-spatial/motor, and memory skills were administered. Between-group differences were assessed. Those in the liberal transfusion group performed more poorly than those in the restrictive group on measures of associative verbal fluency, visual memory, and reading. Findings highlight possible long-term neurodevelopmental consequences of maintaining higher hematocrit levels.

  4. Development and Establishment of Detection Method of Irradiated Foods

    International Nuclear Information System (INIS)

    Byun, Myung Woo; Lee, Ju Woon; Kim, Dong Ho; Jo, Cheo Run; Kim, Jang Ho; Kim, Kyong Su

    2004-12-01

    The present project was related to the development and establishment of the detection techniques for the safety management of gamma-irradiated food and particularly conducted for the establishment of standard detection method for gamma-irradiated dried spices and raw materials, dried meat and fish powder for processed foods, bean paste powder, red pepper paste powder, soy sauce powder, and starch for flavoring ingredients described in 3, 6, 7 section of Korean Food Standard. Since the approvement of gamma-irradiated food items will be enlarged due to the international tendency for gamma-irradiated food, it was concluded that the establishment of detailed detection methods for each food group is not efficient for the enactment and enforcement of related regulations. For this reason, in order to establish the standard detection method, a detection system for gamma-irradiated food suitable for domestic operation was studied using comparative analysis of domestic and foreign research data classified by items and methods and European Standard as a reference. According to the comparative analyses of domestic and foreign research data and regulations of detection for gamma-irradiated food, it was concluded to be desirable that the optimal detection method should be decided after principal detection tests such as physical, chemical, and biological detection methods are established as standard methods and that the specific descriptions such as pre-treatment of raw materials, test methods, and the evaluation of results should be separately prescribed

  5. Development and Establishment of Detection Method of Irradiated Foods

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Myung Woo; Lee, Ju Woon; Kim, Dong Ho; Jo, Cheo Run; Kim, Jang Ho; Kim, Kyong Su

    2004-12-15

    The present project was related to the development and establishment of the detection techniques for the safety management of gamma-irradiated food and particularly conducted for the establishment of standard detection method for gamma-irradiated dried spices and raw materials, dried meat and fish powder for processed foods, bean paste powder, red pepper paste powder, soy sauce powder, and starch for flavoring ingredients described in 3, 6, 7 section of Korean Food Standard. Since the approvement of gamma-irradiated food items will be enlarged due to the international tendency for gamma-irradiated food, it was concluded that the establishment of detailed detection methods for each food group is not efficient for the enactment and enforcement of related regulations. For this reason, in order to establish the standard detection method, a detection system for gamma-irradiated food suitable for domestic operation was studied using comparative analysis of domestic and foreign research data classified by items and methods and European Standard as a reference. According to the comparative analyses of domestic and foreign research data and regulations of detection for gamma-irradiated food, it was concluded to be desirable that the optimal detection method should be decided after principal detection tests such as physical, chemical, and biological detection methods are established as standard methods and that the specific descriptions such as pre-treatment of raw materials, test methods, and the evaluation of results should be separately prescribed.

  6. Effect of scaling and root planing on erythrocyte count, hemoglobin and hematocrit in patients with chronic periodontal disease.

    Science.gov (United States)

    Malhotra, Ranjan; Kapoor, Anoop; Grover, Vishakha; Grover, Deepak; Kaur, Aaswin

    2012-01-01

    Anemia of chronic disease, a cytokine-mediated anemia, is a frequent complication of many chronic inflammatory conditions. The present clinical trial was aimed to evaluate the effect of chronic periodontal disease on erythrocyte count, hemoglobin and hematocrit and the changes produced in these parameters after the provision of periodontal therapy. 40 systemically healthy non-smoker male subjects in the age group of 25 to 50 years suffering with chronic periodontal disease were selected and categorized into 2 groups. Group A was categorized as chronic generalized gingivitis, and Group B was categorized as chronic generalized periodontitis on the basis of clinical findings. The clinical parameters Gingival Index (GI), Probing Pock et Depth (PPD) and Relative Attachment Level (RAL) and laboratory blood investigations viz erythrocyte count (EC), hemoglobin (Hb), hematocrit (HCT) and red cell indices (MCV, MCH, MCHC) were recorded at baseline. Complete oral prophylaxis was performed for all patients. Patients were recalled after 3 weeks and 3 months. The clinical and hematological parameters were re-evaluated to analyze the changes after provision of phase I therapy. The mean values of EC, Hb and HCT were significantly lower in Group B in comparison to Group A, and showed a significantly greater increase at 3 months of observation. However, the values of MCV, MCH and MCHC showed a non significant change during the same observation period in both the groups. Lower values of EC, Hb and HCT in Group B showed that mild anemia is associated with chronic generalized periodontitis, which tends to improve after provision of periodontal therapy. Minimal changes in MCV, MCH and MCHC indicated that the lower values are not due to any vitamin and mineral deficiencies, but secondary to the chronic inflammatory changes associated with chronic periodontal disease.

  7. The health-related quality of life was not improved by targeting higher hemoglobin in the Normal Hematocrit Trial.

    Science.gov (United States)

    Coyne, Daniel W

    2012-07-01

    The Normal Hematocrit Trial (NHT) was the largest trial of epoetin randomizing 1265 hemodialysis patients with cardiac disease to lower (9-11 g/dl) or higher (13-15 g/dl) hemoglobin (Hgb), hypothesizing that higher Hgb would reduce mortality, and improve survival and quality of life. The trial was terminated early, and a 1998 publication reported that targeting higher hematocrit levels led to an insignificant increase in the primary end points (death or myocardial infarct), or risk ratio 1.3, 95% confidence interval (CI), 0.9-1.90, but the P-value was not given, and all-cause death risk was not reported. A higher target reportedly did not increase hospitalization rates, but did significantly improve the 'physical function' domain of quality of life. Comparing the 1996 Food and Drug Administration (FDA)-filed clinical trial report to the 1998 publication, however, found several discrepancies. Among these, the 1998 article reported interim trial results with only the adjusted CI but did not state that the unadjusted CIs were 99.912th percentile, and despite being a secondary end point, reported only the association of achieved Hgb with higher quality of life score. Randomization to the higher target had actually increased the risk for the primary end point (risk ratio 1.28, 95% CI=1.06-1.56; P=0.0112; 99.92% CI=0.92-1.78), the risk of death (risk ratio 1.27, 95% CI=1.04-1.54), non-access thrombotic events (P=0.041), and hospitalization rate (P=0.04), while 'physical function' did not improve (P=0.88). Hence, disclosure of these results in the 1998 publication or access to the FDA-filed report on the NHT in the late 1990s would likely have led to earlier concerns about epoetin safety and greater doubts about its benefits.

  8. Studies on Erythropoietin Bioassay Method

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Kyoung Sam; Ro, Heung Kyu; Lee, Mun Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1975-09-15

    It is the purpose of this paper to design the most preferable method of erythropoietin bioassay in Korea. Bioassay utilizing polycythemic mice are currently in general use for the indirect determination of erythropoietin. Assay animals are usually prepared either by transfusion or by exposure to reduced oxygen tension in specially constructed chamber. We prepared the polycythemic mice by the specially constructed hypobaric chamber. We observed weights and hematocrits of the mice in the hypobaric chamber, then hematocrits and 72 hours {sup 59}Fe red cell uptake ratio of the polycythemic mice induced by hypoxia after removal from the hypobaric chamber. We designed the method of erythropoietin bioassay according to the results obtained by above experiments. Then we measured the 72 hours {sup 59}Fe red cell uptake ratio of the polycythemic mice with normal saline, normal plasma and anemic plasma according to the method we designed. The results are followed:1) The hematocrits of the mice in hypobaric chamber increased to 74% in 11 days. It is preferable to maintain the pressure of the chamber to 400 mmHg for first 4 days then 300 mmHg for last 10 days to reduce the death rate and time consuming in hypobaric chamber. 2) After removal from the hypobaric chamber, the 72 hours {sup 59}Fe red cell uptake ratio decreased rapidly and maintained the lowest level from the fourth day to tenth day. 3) We design the method of erythropoietin bioassay according to the results of above experiment and to the half life of erythropoietin. 4) The Korean product {sup 59}Fe is mixture of {sup 55}Fe and {sup 59}Fe. And the {sup 59}Fe red cell uptake ratio in normal mice was far less with Korean product {sup 59}Fe than with pure {sup 59}Fe of foreign product. So it is desirable to use pure {sup 59}Fe in this method of erythropoietin bioassay. 5) Considering the cost, the technique, the time consuming and the sensitivity it is the most preferable method of erythropoietin bioassay in Korea

  9. Image Processing Methods Usable for Object Detection on the Chessboard

    Directory of Open Access Journals (Sweden)

    Beran Ladislav

    2016-01-01

    Full Text Available Image segmentation and object detection is challenging problem in many research. Although many algorithms for image segmentation have been invented, there is no simple algorithm for image segmentation and object detection. Our research is based on combination of several methods for object detection. The first method suitable for image segmentation and object detection is colour detection. This method is very simply, but there is problem with different colours. For this method it is necessary to have precisely determined colour of segmented object before all calculations. In many cases it is necessary to determine this colour manually. Alternative simply method is method based on background removal. This method is based on difference between reference image and detected image. In this paper several methods suitable for object detection are described. Thisresearch is focused on coloured object detection on chessboard. The results from this research with fusion of neural networks for user-computer game checkers will be applied.

  10. Detection methods for irradiated food

    International Nuclear Information System (INIS)

    Stevenson, M.H.

    1993-01-01

    The plenary lecture gives a brief historical review of the development of methods for the detection of food irradiation and defines the demands on such methods. The methods described in detail are as follows: 1) Physical methods: As examples of luminescence methods, thermoluminescence and chermoluminescence are mentioned; ESR spectroscopy is discussed in detail by means of individual examples (crustaceans, frutis and vegetables, spieces and herbs, nuts). 2) Chemical methods: Examples given for these are methods that make use of alterations in lipids through radiation (formation of long-chain hydrocarbons, formation of 2-alkyl butanones), respectively radiation-induced alterations in the DNA. 3) Microbiological methods. An extensive bibliography is appended. (VHE) [de

  11. An evaluation of modified case definitions for the detection of dengue hemorrhagic fever. Puerto Rico Association of Epidemiologists.

    Science.gov (United States)

    Rigau-Pérez, J G; Bonilla, G L

    1999-12-01

    The case definition for dengue hemorrhagic fever (DHF) requires fever, platelets plasma leakage evidenced by hemoconcentration > or = 20%, pleural or abdominal effusions, hypoproteinemia or hypoalbuminemia. We evaluated the specificity and yield of modified DHF case definitions and the recently proposed World Health Organization criteria for a provisional diagnosis of DHF, using a data base of laboratory-positive and laboratory-negative reports of hospitalizations for suspected dengue in Puerto Rico, 1994 to 1996. By design, all modifications had 100% sensitivity. More liberal criteria for plasma leakage were examined: 1) adding as evidence a single hematocrit > or = 50% (specificity 97.4%); 2) accepting hemoconcentration > or = 10% (specificity 90.1%); and 3) accepting either hematocrit > or = 50% or hemoconcentration > or = 10% (specificity 88.8%). The new DHF cases identified by these definitions (and percent laboratory positive) were 25 (100.0%), 95 (90.5%), and 107 (91.6%), respectively. In contrast, the provisional diagnosis of DHF (fever and hemorrhage, and one or more of platelets or = 20%, or at least a rising hematocrit [redefined quantitatively as a 5% or greater relative change]) showed a specificity of 66.8%, and identified 318 new DHF cases, of which 282 (88.7%) were laboratory-positive. Very small changes in the criteria may result in a large number of new cases. The modification that accepted either hematocrit > or = 50% or hemoconcentration > or = 10% had acceptable specificity, while doubling the detection of DHF-compatible, laboratory-positive severe cases, but "provisional diagnosis" showed even lower specificity, and may produce inflated DHF incidence figures. Modified case definitions should be prospectively evaluated with patients in a health-care facility before they are recommended for widespread use.

  12. Hemoglobin to Hematocrit Ratio: The Strongest Predictor of Femoral Head Osteonecrosis in Children With Sickle Cell Disease.

    Science.gov (United States)

    Worrall, Douglas; Smith-Whitley, Kim; Wells, Lawrence

    2016-03-01

    Femoral head osteonecrosis (ON) secondary to sickle cell disease (SCD) often progresses to femoral head collapse, requiring total hip arthroplasty. However, this treatment has a limited durability and patients with SCD have higher rates of complications, requiring multiple revision operations. Identifying risk factors linked to ON in SCD can facilitate earlier precollapse diagnosis and surgical treatment aimed at preservation of the native hip joint. Fifty-nine children treated at our institution between January 2001 and April 2012 with SCD and ON, as diagnosed by magnetic resonance imaging or radiographic imaging, were compared with age-matched and sickle cell phenotype-matched (SS, SC, Sβ, Sβ) controls with no evidence of ON. Two sided t-tests assuming unequal variances determined statistically risk factors and threshold values were assigned to calculate odds ratios. Systolic blood pressure (P=1.2×10, OR=3.68), diastolic blood pressure (P=0.0084, OR=1.41), weight in the SCD-SS population (P=0.04, OR=1.85), and hemoglobin (Hb) in the SCD-SS population (P=0.036, OR=2.56) were elevated in cases. Curiously, dividing the Hb by the hematocrit to serve as a clinical proxy for the mean corpuscular Hb concentration (MCHC) produced an excellent predictor of ON (P=2.06×10, OR=5.17), which was especially pronounced in the SCD-SS subpopulation (P=2.28×10, OR=8.65). Among children with SCD, the overall prevalence of ON was 9% (59/658) and the phenotype with the highest prevalence of ON was Sβ thalassemia with an ON prevalence of 11.1%. There was no observed correlation between ON and height, body mass index, cholesterol, mean corpuscular volume, hematocrit, or glucocorticoid use. These data support a novel clinical marker, the MCHC proxy, as the strongest predictor of ON in children with SCD. High-risk children should receive hip magnetic resonance imaging to diagnose early ON and facilitate interventions focused on hip preservation, forestalling, or possibly preventing

  13. Novel Method For Low-Rate Ddos Attack Detection

    Science.gov (United States)

    Chistokhodova, A. A.; Sidorov, I. D.

    2018-05-01

    The relevance of the work is associated with an increasing number of advanced types of DDoS attacks, in particular, low-rate HTTP-flood. Last year, the power and complexity of such attacks increased significantly. The article is devoted to the analysis of DDoS attacks detecting methods and their modifications with the purpose of increasing the accuracy of DDoS attack detection. The article details low-rate attacks features in comparison with conventional DDoS attacks. During the analysis, significant shortcomings of the available method for detecting low-rate DDoS attacks were found. Thus, the result of the study is an informal description of a new method for detecting low-rate denial-of-service attacks. The architecture of the stand for approbation of the method is developed. At the current stage of the study, it is possible to improve the efficiency of an already existing method by using a classifier with memory, as well as additional information.

  14. A Novel Unscheduled Islanding Detection Method for Microgrid

    Directory of Open Access Journals (Sweden)

    Li Hui

    2018-01-01

    Full Text Available Microgrid with its intelligent and flexible control characteristics conform to the trend of sustainable development of electricity, and when the microgrid in the unplanned island state, the successful detection of the island is a prerequisite, energy storage inverter as the key equipment in the microgrid system, island protection is one of the necessary functions. In this paper, an improved islanding detection method based on active frequency drift and q-axis reactive power perturbation is proposed. The method has the advantages of faster detection speed and minor influence on power quality, which makes the energy storage inverter with better output power quality when it works on grid-connected state, and can be detected the islanding state quickly from grid-connected mode to islanded mode. Finally, the validity and superiority of the improved island detection method are verified by simulation experiments.

  15. Detecting Android Malwares with High-Efficient Hybrid Analyzing Methods

    Directory of Open Access Journals (Sweden)

    Yu Liu

    2018-01-01

    Full Text Available In order to tackle the security issues caused by malwares of Android OS, we proposed a high-efficient hybrid-detecting scheme for Android malwares. Our scheme employed different analyzing methods (static and dynamic methods to construct a flexible detecting scheme. In this paper, we proposed some detecting techniques such as Com+ feature based on traditional Permission and API call features to improve the performance of static detection. The collapsing issue of traditional function call graph-based malware detection was also avoided, as we adopted feature selection and clustering method to unify function call graph features of various dimensions into same dimension. In order to verify the performance of our scheme, we built an open-access malware dataset in our experiments. The experimental results showed that the suggested scheme achieved high malware-detecting accuracy, and the scheme could be used to establish Android malware-detecting cloud services, which can automatically adopt high-efficiency analyzing methods according to the properties of the Android applications.

  16. Cancer Detection and Diagnosis Methods - Annual Plan

    Science.gov (United States)

    Early cancer detection is a proven life-saving strategy. Learn about the research opportunities NCI supports, including liquid biopsies and other less-invasive methods, for detecting early cancers and precancerous growths.

  17. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Horomichi

    1990-01-01

    The purpose of this study is to estimate the availability of acoustic method for detecting the internal leakage of valves at power plants. Experiments have been carried out on the characteristics of acoustic noise caused by the leak simulated flow. From the experimental results, the mechanism of the acoustic noisegenerated from flow, the relation between acoustic intensity and leak flow velocity, and the characteristics of the acoustic frequency spectrum were clarified. The acoustic method was applied to valves at site, and the background noises were measured in abnormal plant conditions. When the background level is higher than the acoustic signal, the difference between the background noise frequency spectrum and the acoustic signal spectrum provide a very useful leak detection method. (author)

  18. Method of detecting failed fuels

    International Nuclear Information System (INIS)

    Ishizaki, Hideaki; Suzumura, Takeshi.

    1982-01-01

    Purpose: To enable the settlement of the temperature of an adequate filling high temperature pure water by detecting the outlet temperature of a high temperature pure water filling tube to a fuel assembly to control the heating of the pure water and detecting the failed fuel due to the sampling of the pure water. Method: A temperature sensor is provided at a water tube connected to a sipping cap for filling high temperature pure water to detect the temperature of the high temperature pure water at the outlet of the tube, and the temperature is confirmed by a temperature indicator. A heater is controlled on the basis of this confirmation, an adequate high temperature pure water is filled in the fuel assembly, and the pure water is replaced with coolant. Then, it is sampled to settle the adequate temperature of the high temperature coolant used for detecting the failure of the fuel assembly. As a result, the sipping effect does not decrease, and the failed fuel can be precisely detected. (Yoshihara, H.)

  19. System and Method for Multi-Wavelength Optical Signal Detection

    Science.gov (United States)

    McGlone, Thomas D. (Inventor)

    2017-01-01

    The system and method for multi-wavelength optical signal detection enables the detection of optical signal levels significantly below those processed at the discrete circuit level by the use of mixed-signal processing methods implemented with integrated circuit technologies. The present invention is configured to detect and process small signals, which enables the reduction of the optical power required to stimulate detection networks, and lowers the required laser power to make specific measurements. The present invention provides an adaptation of active pixel networks combined with mixed-signal processing methods to provide an integer representation of the received signal as an output. The present invention also provides multi-wavelength laser detection circuits for use in various systems, such as a differential absorption light detection and ranging system.

  20. Steam leak detection method in pipeline using histogram analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Se Oh; Jeon, Hyeong Seop; Son, Ki Sung; Chae, Gyung Sun [Saean Engineering Corp, Seoul (Korea, Republic of); Park, Jong Won [Dept. of Information Communications Engineering, Chungnam NationalUnversity, Daejeon (Korea, Republic of)

    2015-10-15

    Leak detection in a pipeline usually involves acoustic emission sensors such as contact type sensors. These contact type sensors pose difficulties for installation and cannot operate in areas having high temperature and radiation. Therefore, recently, many researchers have studied the leak detection phenomenon by using a camera. Leak detection by using a camera has the advantages of long distance monitoring and wide area surveillance. However, the conventional leak detection method by using difference images often mistakes the vibration of a structure for a leak. In this paper, we propose a method for steam leakage detection by using the moving average of difference images and histogram analysis. The proposed method can separate the leakage and the vibration of a structure. The working performance of the proposed method is verified by comparing with experimental results.

  1. A review on automated pavement distress detection methods

    NARCIS (Netherlands)

    Coenen, Tom B.J.; Golroo, Amir

    2017-01-01

    In recent years, extensive research has been conducted on pavement distress detection. A large part of these studies applied automated methods to capture different distresses. In this paper, a literature review on the distresses and related detection methods are presented. This review also includes

  2. Method for predicting peptide detection in mass spectrometry

    Science.gov (United States)

    Kangas, Lars [West Richland, WA; Smith, Richard D [Richland, WA; Petritis, Konstantinos [Richland, WA

    2010-07-13

    A method of predicting whether a peptide present in a biological sample will be detected by analysis with a mass spectrometer. The method uses at least one mass spectrometer to perform repeated analysis of a sample containing peptides from proteins with known amino acids. The method then generates a data set of peptides identified as contained within the sample by the repeated analysis. The method then calculates the probability that a specific peptide in the data set was detected in the repeated analysis. The method then creates a plurality of vectors, where each vector has a plurality of dimensions, and each dimension represents a property of one or more of the amino acids present in each peptide and adjacent peptides in the data set. Using these vectors, the method then generates an algorithm from the plurality of vectors and the calculated probabilities that specific peptides in the data set were detected in the repeated analysis. The algorithm is thus capable of calculating the probability that a hypothetical peptide represented as a vector will be detected by a mass spectrometry based proteomic platform, given that the peptide is present in a sample introduced into a mass spectrometer.

  3. A Bayesian method for detecting stellar flares

    Science.gov (United States)

    Pitkin, M.; Williams, D.; Fletcher, L.; Grant, S. D. T.

    2014-12-01

    We present a Bayesian-odds-ratio-based algorithm for detecting stellar flares in light-curve data. We assume flares are described by a model in which there is a rapid rise with a half-Gaussian profile, followed by an exponential decay. Our signal model also contains a polynomial background model required to fit underlying light-curve variations in the data, which could otherwise partially mimic a flare. We characterize the false alarm probability and efficiency of this method under the assumption that any unmodelled noise in the data is Gaussian, and compare it with a simpler thresholding method based on that used in Walkowicz et al. We find our method has a significant increase in detection efficiency for low signal-to-noise ratio (S/N) flares. For a conservative false alarm probability our method can detect 95 per cent of flares with S/N less than 20, as compared to S/N of 25 for the simpler method. We also test how well the assumption of Gaussian noise holds by applying the method to a selection of `quiet' Kepler stars. As an example we have applied our method to a selection of stars in Kepler Quarter 1 data. The method finds 687 flaring stars with a total of 1873 flares after vetos have been applied. For these flares we have made preliminary characterizations of their durations and and S/N.

  4. Relationship of hemoglobin and hematocrit to systolic function in advanced heart failure.

    Science.gov (United States)

    Guglin, Maya; Darbinyan, Nellie

    2012-01-01

    The dataset from the Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness (ESCAPE) trial provides a rare opportunity to evaluate the whole spectrum of associations of hemoglobin (HB) and hematocrit (HCT) in heart failure (HF). In that trial, subjective and objective data were recorded at multiple time points when HB and HCT were also measured. We investigated the relationship between anemia and ventricular systolic function. A limited access dataset from the ESCAPE trial, provided by the National Heart, Lung and Blood Institute, was analyzed. Linear regression analysis, correlation coefficients and Student's t test were utilized. Besides the known association of anemia with poor prognosis, more severe symptoms, decreased functional capacity and impaired kidney function, we found a significant and very consistent inverse correlation between HB and HCT and ventricular contractility. Both left ventricular ejection fraction and right ventricular fractional area change improved with a decrease in HB and vice versa. We hypothesize that this effect can result from a change in viscosity, which decreases with a decrease in HCT, and may facilitate adaptation of the heart to a volume overload state accompanied by hemodilution. In HF, anemia is associated with poor prognosis and functional impairment, but also with mildly improved systolic function. It may represent an adaptive reaction to congestion. Copyright © 2012 S. Karger AG, Basel.

  5. Mobile/android application for QRS detection using zero cross method

    Science.gov (United States)

    Rizqyawan, M. I.; Simbolon, A. I.; Suhendra, M. A.; Amri, M. F.; Kusumandari, D. E.

    2018-03-01

    In automatic ECG signal processing, one of the main topics of research is QRS complex detection. Detecting correct QRS complex or R peak is important since it is used to measure several other ECG metrics. One of the robust methods for QRS detection is Zero Cross method. This method uses an addition of high-frequency signal and zero crossing count to detect QRS complex which has a low-frequency oscillation. This paper presents an application of QRS detection using Zero Cross algorithm in the Android-based system. The performance of the algorithm in the mobile environment is measured. The result shows that this method is suitable for real-time QRS detection in a mobile application.

  6. Adjunct methods for caries detection

    DEFF Research Database (Denmark)

    Twetman, Svante; Axelsson, Susanna Bihari; Dahlén, Gunnar

    2012-01-01

    Abstract Objective. To assess the diagnostic accuracy of adjunct methods used to detect and quantify dental caries. Study design. A systematic literature search for relevant papers was conducted with pre-determined inclusion and exclusion criteria. Abstracts and full text articles were assessed...

  7. Support system and method for detecting neurodegenerative disorder

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to a system and a method for detection of abnormal motor activity during REM sleep, and further to systems and method for assisting in detecting neurodegenerative disorders such as Parkinson's. One embodiment relates to a method for detection of abnormal motor activity...... during REM sleep comprising the steps of: performing polysomnographic recordings of a sleeping subject, thereby obtaining one or more electromyography (EMG) derivations, preferably surface EMG recordings, and one or more EEG derivations, and/or one or more electrooculargraphy (EOG) derivations, detecting...... one or more REM sleep stages, preferably based on the one or more EEG and/or EOG derivations, determining the level of muscle activity during the one or more REM sleep stages based on the one or more EMG derivations, wherein a subject having an increased level of muscle activity during REM sleep...

  8. Concrete deterioration: detection by ultrasonic pulse velocity method

    International Nuclear Information System (INIS)

    Sutan, N.M.; Jaafar, M.S.; Hamdan, S.

    2003-01-01

    Tests were performed to evaluate the feasibility of using Ultrasonic Pulse Velocity Method (UPVM) in detecting defect and determining its depth during the early age concrete. Five reinforced concrete (RC) slabs of grade 30, 40 and 50 specimens at day 3, 7,14 and 28 with a fabricated void at a known location were used. The results obtained were compared to determine the accuracy of the method hence the effectiveness of the method with different strength and as the concrete matures. This method detects defects in specimens during the early age The accuracy varies with concrete strength and as the concrete mature. The test results indicate the method can be used to assess the in-situ properties of concrete or for quality control on site. The method showed better accuracy with stronger concrete detects defects with the accuracy ranging from 55.75-99.62% from day 3-28 (full strength) respectively. (author)

  9. Research on Quality Detection Methods for Automotive Transmission

    Directory of Open Access Journals (Sweden)

    Sheng FU

    2014-04-01

    Full Text Available Given the problems in intelligent diagnosis methods for automotive transmission, it is difficult to obtain the fault signal features and a large enough sample size to study. To solve these problems, a method integrating order tracking, cepstrum, support vector machine (SVM and extremal curve is proposed in this paper. Order tracking and cepstrum are combined for processing the non- stationary vibration signal emitted by automotive transmission. As conventional intelligent methods cannot produce true results for insufficient samples, a method that combines SVM and extremal curve is presented. Input the vector acquired from the feature signals into the SVM model for the first detection, and then do the second detection by means of extremal curve which in turn can enrich the training samples in SVM model thus making the SVM model be more perfect. Analytical description and experimental studies are presented for the methods of signal processing and quality detection. The experimental results demonstrate the effectiveness and practicability of the proposed method.

  10. Method of detecting irradiated pepper

    International Nuclear Information System (INIS)

    Doumaru, Takaaki; Furuta, Masakazu; Katayama, Tadashi; Toratani, Hirokazu; Takeda, Atsuhiko

    1989-01-01

    Spices represented by pepper are generally contaminated by microorganisms, and for using them as foodstuffs, some sterilizing treatment is indispensable. However, heating is not suitable to spices, accordingly ethylene oxide gas sterilization has been inevitably carried out, but its carcinogenic property is a problem. Food irradiation is the technology for killing microorganisms and noxious insects which cause the rotting and spoiling of foods and preventing the germination, which is an energy-conserving method without the fear of residual chemicals, therefore, it is most suitable to the sterilization of spices. In the irradiation of lower than 10 kGy, the toxicity test is not required for any food, and the irradiation of spices is permitted in 20 countries. However, in order to establish the international distribution organization for irradiated foods, the PR to consumers and the development of the means of detecting irradiation are the important subjects. The authors used pepper, and examined whether the hydrogen generated by irradiation remains in seeds and it can be detected or not. The experimental method and the results are reported. From the samples without irradiation, hydrogen was scarcely detected. The quantity of hydrogen generated was proportional to dose. The measuring instrument is only a gas chromatograph. (K.I.)

  11. Rapid radiometric method for detection of Salmonella in foods

    International Nuclear Information System (INIS)

    Stewart, B.J.; Eyles, M.J.; Murrell, W.G.

    1980-01-01

    A radiometric method for the detection of Salmonella in foods has been developed which is based on Salmonella poly H agglutinating serum preventing Salmonella from producing 14CO2 from [14C] dulcitol. The method will detect the presence or absence of Salmonella in a product within 30 h compared to 4 to 5 days by routine culture methods. The method has been evaluated against a routine culture method using 58 samples of food. The overall agreement was 91%. Five samples negative for Salmonella by the routine method were positive by the radiometric method. These may have been false positives. However, the routine method may have failed to detect Salmonella due to the presence of large numbers of lactose-fermenting bacteria which hindered isolation of Salmonella colonies on the selective agar plates

  12. Multiple-Features-Based Semisupervised Clustering DDoS Detection Method

    Directory of Open Access Journals (Sweden)

    Yonghao Gu

    2017-01-01

    Full Text Available DDoS attack stream from different agent host converged at victim host will become very large, which will lead to system halt or network congestion. Therefore, it is necessary to propose an effective method to detect the DDoS attack behavior from the massive data stream. In order to solve the problem that large numbers of labeled data are not provided in supervised learning method, and the relatively low detection accuracy and convergence speed of unsupervised k-means algorithm, this paper presents a semisupervised clustering detection method using multiple features. In this detection method, we firstly select three features according to the characteristics of DDoS attacks to form detection feature vector. Then, Multiple-Features-Based Constrained-K-Means (MF-CKM algorithm is proposed based on semisupervised clustering. Finally, using MIT Laboratory Scenario (DDoS 1.0 data set, we verify that the proposed method can improve the convergence speed and accuracy of the algorithm under the condition of using a small amount of labeled data sets.

  13. Detection methods for irradiated foods

    International Nuclear Information System (INIS)

    Dyakova, A.; Tsvetkova, E.; Nikolova, R.

    2005-01-01

    In connection with the ongoing world application of irradiation as a technology in Food industry for increasing food safety, it became a need for methods of identification of irradiation. It was required to control international trade of irradiated foods, because of the certain that legally imposed food laws are not violated; supervise correct labeling; avoid multiple irradiation. Physical, chemical and biological methods for detection of irradiated foods as well principle that are based, are introducing in this summary

  14. Simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in humans and other animal models using a single light source

    Science.gov (United States)

    Dent, Paul; Tun, Sai Han; Fillioe, Seth; Deng, Bin; Satalin, Josh; Nieman, Gary; Wilcox, Kailyn; Searles, Quinn; Narsipur, Sri; Peterson, Charles M.; Goodisman, Jerry; Mostrom, James; Steinmann, Richard; Chaiken, J.

    2018-02-01

    We previously reported a new algorithm "PV[O]H" for continuous, noninvasive, in vivo monitoring of hematocrit changes in blood and have since shown its utility for monitoring in humans during 1) hemodialysis, 2) orthostatic perturbations and 3) during blood loss and fluid replacement in a rat model. We now show that the algorithm is sensitive to changes in hemoglobin oxygen saturation. We document the phenomenology of the effect and explain the effect using new results obtained from humans and rat models. The oxygen sensitivity derives from the differential absorption of autofluorescence originating in the static tissues by oxy and deoxy hemoglobin. Using this approach we show how to perform simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in mammals using a single light source. We suspect that monitoring of changes in this suite of vital signs can be provided with improved time response, sensitivity and precision compared to existing methodologies. Initial results also offer a more detailed glimpse into the systemic oxygen transport in the circulatory system of humans.

  15. Dim target detection method based on salient graph fusion

    Science.gov (United States)

    Hu, Ruo-lan; Shen, Yi-yan; Jiang, Jun

    2018-02-01

    Dim target detection is one key problem in digital image processing field. With development of multi-spectrum imaging sensor, it becomes a trend to improve the performance of dim target detection by fusing the information from different spectral images. In this paper, one dim target detection method based on salient graph fusion was proposed. In the method, Gabor filter with multi-direction and contrast filter with multi-scale were combined to construct salient graph from digital image. And then, the maximum salience fusion strategy was designed to fuse the salient graph from different spectral images. Top-hat filter was used to detect dim target from the fusion salient graph. Experimental results show that proposal method improved the probability of target detection and reduced the probability of false alarm on clutter background images.

  16. [Optimized application of nested PCR method for detection of malaria].

    Science.gov (United States)

    Yao-Guang, Z; Li, J; Zhen-Yu, W; Li, C

    2017-04-28

    Objective To optimize the application of the nested PCR method for the detection of malaria according to the working practice, so as to improve the efficiency of malaria detection. Methods Premixing solution of PCR, internal primers for further amplification and new designed primers that aimed at two Plasmodium ovale subspecies were employed to optimize the reaction system, reaction condition and specific primers of P . ovale on basis of routine nested PCR. Then the specificity and the sensitivity of the optimized method were analyzed. The positive blood samples and examination samples of malaria were detected by the routine nested PCR and the optimized method simultaneously, and the detection results were compared and analyzed. Results The optimized method showed good specificity, and its sensitivity could reach the pg to fg level. The two methods were used to detect the same positive malarial blood samples simultaneously, the results indicated that the PCR products of the two methods had no significant difference, but the non-specific amplification reduced obviously and the detection rates of P . ovale subspecies improved, as well as the total specificity also increased through the use of the optimized method. The actual detection results of 111 cases of malarial blood samples showed that the sensitivity and specificity of the routine nested PCR were 94.57% and 86.96%, respectively, and those of the optimized method were both 93.48%, and there was no statistically significant difference between the two methods in the sensitivity ( P > 0.05), but there was a statistically significant difference between the two methods in the specificity ( P PCR can improve the specificity without reducing the sensitivity on the basis of the routine nested PCR, it also can save the cost and increase the efficiency of malaria detection as less experiment links.

  17. A comparison of three time-domain anomaly detection methods

    Energy Technology Data Exchange (ETDEWEB)

    Schoonewelle, H.; Hagen, T.H.J.J. van der; Hoogenboom, J.E. [Delft University of Technology (Netherlands). Interfaculty Reactor Institute

    1996-01-01

    Three anomaly detection methods based on a comparison of signal values with predictions from an autoregressive model are presented. These methods are: the extremes method, the {chi}{sup 2} method and the sequential probability ratio test. The methods are used to detect a change of the standard deviation of the residual noise obtained from applying an autoregressive model. They are fast and can be used in on-line applications. For each method some important anomaly detection parameters are determined by calculation or simulation. These parameters are: the false alarm rate, the average time to alarm and - being of minor importance -the alarm failure rate. Each method is optimized with respect to the average time to alarm for a given value of the false alarm rate. The methods are compared with each other, resulting in the sequential probability ratio test being clearly superior. (author).

  18. A comparison of three time-domain anomaly detection methods

    International Nuclear Information System (INIS)

    Schoonewelle, H.; Hagen, T.H.J.J. van der; Hoogenboom, J.E.

    1996-01-01

    Three anomaly detection methods based on a comparison of signal values with predictions from an autoregressive model are presented. These methods are: the extremes method, the χ 2 method and the sequential probability ratio test. The methods are used to detect a change of the standard deviation of the residual noise obtained from applying an autoregressive model. They are fast and can be used in on-line applications. For each method some important anomaly detection parameters are determined by calculation or simulation. These parameters are: the false alarm rate, the average time to alarm and - being of minor importance -the alarm failure rate. Each method is optimized with respect to the average time to alarm for a given value of the false alarm rate. The methods are compared with each other, resulting in the sequential probability ratio test being clearly superior. (author)

  19. Novel methods for detecting buried explosive devices

    Energy Technology Data Exchange (ETDEWEB)

    Kercel, S.W.; Burlage, R.S.; Patek, D.R.; Smith, C.M. [Oak Ridge National Lab., TN (United States); Hibbs, A.D.; Rayner, T.J. [Quantum Magnetics, Inc., San Diego, CA (United States)

    1997-04-01

    Oak Ridge National Laboratory (ORNL) and Quantum Magnetics, Inc. (QM) are exploring novel landmine detection technologies. Technologies considered here include bioreporter bacteria, swept acoustic resonance, nuclear quadrupole resonance (NQR), and semiotic data fusion. Bioreporter bacteria look promising for third-world humanitarian applications; they are inexpensive, and deployment does not require high-tech methods. Swept acoustic resonance may be a useful adjunct to magnetometers in humanitarian demining. For military demining, NQR is a promising method for detecting explosive substances; of 50,000 substances that have been tested, none has an NQR signature that can be mistaken for RDX or TNT. For both military and commercial demining, sensor fusion entails two daunting tasks, identifying fusible features in both present-day and emerging technologies, and devising a fusion algorithm that runs in real-time on cheap hardware. Preliminary research in these areas is encouraging. A bioreporter bacterium for TNT detection is under development. Investigation has just started in swept acoustic resonance as an approach to a cheap mine detector for humanitarian use. Real-time wavelet processing appears to be a key to extending NQR bomb detection into mine detection, including TNT-based mines. Recent discoveries in semiotics may be the breakthrough that will lead to a robust fused detection scheme.

  20. Modification of postnatal hemoglobin level and hematocrit value in the peripheral blood of mice after gamma radiation in utero by MPG (2-mercaptopropionylglycine)

    International Nuclear Information System (INIS)

    Goyal, P.K.; Kumar, S.; Dev, P.K.

    1980-01-01

    Pregnant Swiss albino mice were irradiated with oamma radiation at post-conception days 14.5, 16.25 and 18.25. Hemoglobin level and hematocrit value in the peripheral blood of the male offsprings were found to be below normal during the early postnatal development. The value became normal from 4 week onwards. However these values were found to be significantly elevated in the early postnatal development of the male offsprings of the mice which were administered MPG before irradiation. The possible radioprotective mechanism of MPG is discussed. (M.G.B.)

  1. A New Outlier Detection Method for Multidimensional Datasets

    KAUST Repository

    Abdel Messih, Mario A.

    2012-07-01

    This study develops a novel hybrid method for outlier detection (HMOD) that combines the idea of distance based and density based methods. The proposed method has two main advantages over most of the other outlier detection methods. The first advantage is that it works well on both dense and sparse datasets. The second advantage is that, unlike most other outlier detection methods that require careful parameter setting and prior knowledge of the data, HMOD is not very sensitive to small changes in parameter values within certain parameter ranges. The only required parameter to set is the number of nearest neighbors. In addition, we made a fully parallelized implementation of HMOD that made it very efficient in applications. Moreover, we proposed a new way of using the outlier detection for redundancy reduction in datasets where the confidence level that evaluates how accurate the less redundant dataset can be used to represent the original dataset can be specified by users. HMOD is evaluated on synthetic datasets (dense and mixed “dense and sparse”) and a bioinformatics problem of redundancy reduction of dataset of position weight matrices (PWMs) of transcription factor binding sites. In addition, in the process of assessing the performance of our redundancy reduction method, we developed a simple tool that can be used to evaluate the confidence level of reduced dataset representing the original dataset. The evaluation of the results shows that our method can be used in a wide range of problems.

  2. Quench detection method for 2G HTS wire

    International Nuclear Information System (INIS)

    Marchevsky, M; Xie, Y-Y; Selvamanickam, V

    2010-01-01

    2G HTS conductors are increasingly used in various commercial applications and their thermal and electrical stability is an important reliability factor. Detection and prevention of quenches in 2G wire-based cables and solenoids has proven to be a difficult engineering task. This is largely due to a very slow normal zone propagation in coated conductors that leads to formation of localized hotspots while the rest of the conductor remains in the superconducting state. We propose an original method of quench and hotspot detection for 2G wires and coils that is based upon local magnetic sensing and takes advantage of 2G wire planar geometry. We demonstrate our technique experimentally and show that its sensitivity is superior to the known voltage detection scheme. A unique feature of the method is its capability to remotely detect instant degradation of the wire critical current even before a normal zone is developed within the conductor. Various modifications of the method applicable to practical device configurations are discussed.

  3. Quench detection method for 2G HTS wire

    Energy Technology Data Exchange (ETDEWEB)

    Marchevsky, M; Xie, Y-Y; Selvamanickam, V, E-mail: maxmarche@gmail.co, E-mail: yxie@superpower-inc.co [SuperPower, Inc., 450 Duane Avenue, Schenectady, NY 12304 (United States)

    2010-03-15

    2G HTS conductors are increasingly used in various commercial applications and their thermal and electrical stability is an important reliability factor. Detection and prevention of quenches in 2G wire-based cables and solenoids has proven to be a difficult engineering task. This is largely due to a very slow normal zone propagation in coated conductors that leads to formation of localized hotspots while the rest of the conductor remains in the superconducting state. We propose an original method of quench and hotspot detection for 2G wires and coils that is based upon local magnetic sensing and takes advantage of 2G wire planar geometry. We demonstrate our technique experimentally and show that its sensitivity is superior to the known voltage detection scheme. A unique feature of the method is its capability to remotely detect instant degradation of the wire critical current even before a normal zone is developed within the conductor. Various modifications of the method applicable to practical device configurations are discussed.

  4. System and method for anomaly detection

    Science.gov (United States)

    Scherrer, Chad

    2010-06-15

    A system and method for detecting one or more anomalies in a plurality of observations is provided. In one illustrative embodiment, the observations are real-time network observations collected from a stream of network traffic. The method includes performing a discrete decomposition of the observations, and introducing derived variables to increase storage and query efficiencies. A mathematical model, such as a conditional independence model, is then generated from the formatted data. The formatted data is also used to construct frequency tables which maintain an accurate count of specific variable occurrence as indicated by the model generation process. The formatted data is then applied to the mathematical model to generate scored data. The scored data is then analyzed to detect anomalies.

  5. Detection of irradiated food - methods and routine applications

    International Nuclear Information System (INIS)

    Schreiber, G.A.; Helle, N.; Boegl, K.W.

    1993-01-01

    Irradiation of food for the purposes of extension of shelf life, control of microbial load, reduction of pathogenic microorganisms and disinfection is regarded by many consumers with suspicion. One reason is the lack of methods within food-controlling laboratories which can detect irradiation treatment and which are applied to control correct labelling. This review describes the potential of various methods to reveal irradiation treatment. Special emphasis is given to the three most successful methods, thermoluminescence, electron spin resonance spectroscopy and detection of volatiles. The possibilities and limitations of applying the methods in routine control are discussed. (author)

  6. Fuel rod failure detection method and system

    International Nuclear Information System (INIS)

    Assmann, H.; Janson, W.; Stehle, H.; Wahode, P.

    1975-01-01

    The inventor claims a method for the detection of a defective fuel rod cladding tube or of inleaked water in the cladding tube of a fuel rod in the fuel assembly of a pressurized-water reactor. The fuel assembly is not disassembled but examined as a whole. In the examination, the cladding tube is heated near one of its two end plugs, e.g. with an attached high-frequency inductor. The water contained in the cladding tube evaporates, and steam bubbles or a condensate are detected by the ultrasonic impulse-echo method. It is also possible to measure the delay of the temperature rise at the end plug or to determine the cooling energy required to keep the end plug temperature stable and thus to detect water ingression. (DG/AK) [de

  7. GC ‘Multi-Analyte’ Detection Method

    Energy Technology Data Exchange (ETDEWEB)

    Dudar, E. [Plant Protection & Soil Conservation Service of Budapest, Budapest (Hungary)

    2009-07-15

    Elaborated methodologies for GC multi-analyte detection are presented, comprising the steps of method development, chromatographic conditions and procedures including the determination of relative retention times and summary results tables. (author)

  8. Transistor-based particle detection systems and methods

    Science.gov (United States)

    Jain, Ankit; Nair, Pradeep R.; Alam, Muhammad Ashraful

    2015-06-09

    Transistor-based particle detection systems and methods may be configured to detect charged and non-charged particles. Such systems may include a supporting structure contacting a gate of a transistor and separating the gate from a dielectric of the transistor, and the transistor may have a near pull-in bias and a sub-threshold region bias to facilitate particle detection. The transistor may be configured to change current flow through the transistor in response to a change in stiffness of the gate caused by securing of a particle to the gate, and the transistor-based particle detection system may configured to detect the non-charged particle at least from the change in current flow.

  9. A highly sensitive method for detection of molybdenum-containing proteins

    International Nuclear Information System (INIS)

    Kalakutskii, K.L.; Shvetsov, A.A.; Bursakov, S.A.; Letarov, A.V.; Zabolotnyi, A.I.; L'vov, N.P.

    1992-01-01

    A highly sensitive method for detection of molybdenum-containing proteins in gels after electrophoresis has been developed. The method involves in vitro labeling of the proteins with the radioactive isotope 185 W. The method used to detect molybdenum-accumulating proteins in lupine seeds, xanthine dehydrogenase and another molybdenum-containing protein in wheat, barley, and pea seedlings, and nitrate reductase and xanthine dehydrogenase in bacteroides from lupine nodules. Nitrogenase could not be detected by the method. 16 refs., 5 figs

  10. The comparison of detection methods of asymptomatic malaria in hypoendemic areas

    Science.gov (United States)

    Siahaan, L.; Panggabean, M.; Panggabean, Y. C.

    2018-03-01

    Malaria is still a problem that disrupts public health in North Sumatera. Late diagnosis will increase the chances of increased morbidity and mortality due to malaria. The early detection of asymptomatic malaria is one of the best efforts to reduce the transmission of the disease. Early detection is certainly must be done on suspect patients who have no malaria complaints. Passive Case Detection (PCD) methods seem hard to find asymptomatic malaria. This study was conducted to compare ACD (Active Case Detection) and PCD methods in asymptomatic malaria detection in the hypoendemic areas of malaria. ACD method is done by going to the sample based on secondary data. Meanwhile, PCD is done on samples that come to health services. Samples were taken randomly and diagnosis was confirmed by microscopic examination with 3% Giemsa staining, as gold standard of malaria diagnostics. There was a significant difference between ACD and PCD detection methods (p = 0.034), where ACD method was seen superior in detecting malaria patients in all categories, such as: clinical malaria (65.2%), asymptomatic malaria (65.1%) and submicroscopic malaria (58.5%). ACD detection methods are superior in detecting malaria sufferers, especially asymptomatic malaria sufferers.

  11. Musical Tone Law Method for the Structural Damage Detection

    Directory of Open Access Journals (Sweden)

    Weisong Yang

    2017-01-01

    Full Text Available Damage detection tests of inclined cables, steel pipes, spherical shells, and an actual cable-stayed bridge were conducted based on the proposed musical tone law method. The results show that the musical tone law method could be used in the damage detection of isotropic material structures with simple shape, like cables, pipes, plates, and shells. Having distinct spectral lines like a comb with a certain interval distribution rule is the main characteristic of the music tone law. Damage detection baseline could be established by quantizing the fitting relationship between modal orders and the corresponding frequency values. The main advantage of this method is that it could be used in the structural damage detection without vibration information of an intact structure as a reference.

  12. Detection methods for legionellae. Possibilities and limitations of detection methods; Niet alle detectiemethoden geschikt voor legionellagroei. Mogelijkheden en beperkingen detectiemethoden

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, W.

    2011-06-15

    This article provides an overview of existing and new methods for detecting legionella in water. It offers insight in the characteristics and applications of existing and new detection methods. However, it is impossible to assess the value of alternative methods at the moment. That will require additional research. [Dutch] Een overzicht is gemaakt van bestaande en nieuwe methoden om legionella in water aan te tonen. Daarmee wordt inzicht verkregen in de kenmerken en toepassingsmogelijkheden van bestaande en nieuwe detectiemethoden. De waarde van alternatieve methoden in een installatie kan echter nog niet worden beoordeeld. Daarvoor is nader onderzoek nodig.

  13. DIAGNOSTIC METHODS IN BREAST CANCER DETECTION

    Directory of Open Access Journals (Sweden)

    Kristijana Hertl

    2018-02-01

    Full Text Available Background. In the world as well as in Slovenia, breast cancer is the most frequent female cancer. Due to its high incidence, it appears to be a serious health and economic problem. Content. Among other, tumour size at diagnosis, is an important prognostic factors of the course of the disease. The probability of axillary lymph node involvement as well as distant metastases is greater in larger tumours. This is the reason that encouraged the development of various diagnostic methods for early detection of small, clinically non-palpable breast tumours. Mammography, however, remains the »golden standard« of early breast cancer detection. It is the basic diagnostic method applied in all symptomatic women over 35 years of age and in asymptomatic women over 40 years of age. Ultrasonography (US, additional projections, magnetic resonance imaging (MRI and ductography are regarded as complementary diagnostic breast imaging techniques in addition to mammography. The detected changes in the breast can be further confirmed by US-, MR-guided or stereotactic biopsy. If necessary, surgical biopsy and the excision of a tissue sample, after wire or isotope localisation of the nonpalpable lesion, can be performed. Conclusions. Any of the above mentioned diagnostic methods has advantages as well as drawbacks and only detailed knowledge and understanding of each of them may assure the best option.

  14. A divisive spectral method for network community detection

    International Nuclear Information System (INIS)

    Cheng, Jianjun; Li, Longjie; Yao, Yukai; Chen, Xiaoyun; Leng, Mingwei; Lu, Weiguo

    2016-01-01

    Community detection is a fundamental problem in the domain of complex network analysis. It has received great attention, and many community detection methods have been proposed in the last decade. In this paper, we propose a divisive spectral method for identifying community structures from networks which utilizes a sparsification operation to pre-process the networks first, and then uses a repeated bisection spectral algorithm to partition the networks into communities. The sparsification operation makes the community boundaries clearer and sharper, so that the repeated spectral bisection algorithm extract high-quality community structures accurately from the sparsified networks. Experiments show that the combination of network sparsification and a spectral bisection algorithm is highly successful, the proposed method is more effective in detecting community structures from networks than the others. (paper: interdisciplinary statistical mechanics)

  15. Fuel failure detection and location methods in CAGRs

    International Nuclear Information System (INIS)

    Harris, A.M.

    1982-06-01

    The release of fission products from AGR fuel failures and the way in which the signals from such failures must be detected against the background signal from uranium contamination of the fuel is considered. Theoretical assessments of failure detection are used to show the limitations of the existing Electrostatic Wire Precipitator Burst Can Detection system (BCD) and how its operating parameters can be optimised. Two promising alternative methods, the 'split count' technique and the use of iodine measurements, are described. The results of a detailed study of the mechanical and electronic performance of the present BCD trolleys are given. The limited experience of detection and location of two fuel failures in CAGR using conventional and alternative methods is reviewed. The larger failure was detected and located using the conventional BCD equipment with a high confidence level. It is shown that smaller failures may not be easy to detect and locate using the current BCD equipment, and the second smaller failure probably remained in the reactor for about a year before it was discharged. The split count technique used with modified BCD equipment was able to detect the smaller failure after careful inspection of the data. (author)

  16. Variable threshold method for ECG R-peak detection.

    Science.gov (United States)

    Kew, Hsein-Ping; Jeong, Do-Un

    2011-10-01

    In this paper, a wearable belt-type ECG electrode worn around the chest by measuring the real-time ECG is produced in order to minimize the inconvenient in wearing. ECG signal is detected using a potential instrument system. The measured ECG signal is transmits via an ultra low power consumption wireless data communications unit to personal computer using Zigbee-compatible wireless sensor node. ECG signals carry a lot of clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed. There will be errors in peak detection when the baseline changes due to motion artifacts and signal size changes. Preprocessing process which includes differentiation process and Hilbert transform is used as signal preprocessing algorithm. Thereafter, variable threshold method is used to detect the R-peak which is more accurate and efficient than fixed threshold value method. R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research in order to evaluate the performance analysis.

  17. Thermal History Devices, Systems For Thermal History Detection, And Methods For Thermal History Detection

    KAUST Repository

    Caraveo Frescas, Jesus Alfonso; Alshareef, Husam N.

    2015-01-01

    Embodiments of the present disclosure include nanowire field-effect transistors, systems for temperature history detection, methods for thermal history detection, a matrix of field effect transistors, and the like.

  18. Thermal History Devices, Systems For Thermal History Detection, And Methods For Thermal History Detection

    KAUST Repository

    Caraveo Frescas, Jesus Alfonso

    2015-05-28

    Embodiments of the present disclosure include nanowire field-effect transistors, systems for temperature history detection, methods for thermal history detection, a matrix of field effect transistors, and the like.

  19. An Examination of Three Spatial Event Cluster Detection Methods

    Directory of Open Access Journals (Sweden)

    Hensley H. Mariathas

    2015-03-01

    Full Text Available In spatial disease surveillance, geographic areas with large numbers of disease cases are to be identified, so that targeted investigations can be pursued. Geographic areas with high disease rates are called disease clusters and statistical cluster detection tests are used to identify geographic areas with higher disease rates than expected by chance alone. In some situations, disease-related events rather than individuals are of interest for geographical surveillance, and methods to detect clusters of disease-related events are called event cluster detection methods. In this paper, we examine three distributional assumptions for the events in cluster detection: compound Poisson, approximate normal and multiple hypergeometric (exact. The methods differ on the choice of distributional assumption for the potentially multiple correlated events per individual. The methods are illustrated on emergency department (ED presentations by children and youth (age < 18 years because of substance use in the province of Alberta, Canada, during 1 April 2007, to 31 March 2008. Simulation studies are conducted to investigate Type I error and the power of the clustering methods.

  20. Leak detection device for control rod drive and detection method therefor

    International Nuclear Information System (INIS)

    Imasaki, Yoshio.

    1997-01-01

    The present invention provides a detection device for leak of cooling water from a sealed axial portion of control rod drives (CRD) disposed in a BWR type reactor and a monitoring method therefor. Namely, the CRD transfers rotation at the sealed axial portion and elevates/lowers a piston to insert/withdraw control rod into/from the reactor core. High pressure water is injected upon occurrence of scram to urge the piston upwardly thereby rapidly inserting the control rods. Leak detection pipelines are laid from the sealed axial portion. A flow glass is connected to the leak detection pipelines. Then, cooling water leaked from the sealed axial portion flows in the leak detection pipelines and flows into the flow glass. The flow rate of cooling water leaked from the sealed axial portion of the CRD can thus be detected by monitoring the flow glass. In addition, a flowmeter is connected to the leak detection pipelines, or the flowmeter and the flow glass are connected, and a flowmeter is connected downstream. Then, the flow rate of the leaked cooling water can be detected automatically. (I.S.)

  1. Molecular methods for the detection of mutations.

    Science.gov (United States)

    Monteiro, C; Marcelino, L A; Conde, A R; Saraiva, C; Giphart-Gassler, M; De Nooij-van Dalen, A G; Van Buuren-van Seggelen, V; Van der Keur, M; May, C A; Cole, J; Lehmann, A R; Steinsgrimsdottir, H; Beare, D; Capulas, E; Armour, J A

    2000-01-01

    We report the results of a collaborative study aimed at developing reliable, direct assays for mutation in human cells. The project used common lymphoblastoid cell lines, both with and without mutagen treatment, as a shared resource to validate the development of new molecular methods for the detection of low-level mutations in the presence of a large excess of normal alleles. As the "gold standard, " hprt mutation frequencies were also measured on the same samples. The methods under development included i) the restriction site mutation (RSM) assay, in which mutations lead to the destruction of a restriction site; ii) minisatellite length-change mutation, in which mutations lead to alleles containing new numbers of tandem repeat units; iii) loss of heterozygosity for HLA epitopes, in which antibodies can be used to direct selection for mutant cells; iv) multiple fluorescence-based long linker arm nucleotides assay (mf-LLA) technology, for the detection of substitutional mutations; v) detection of alterations in the TP53 locus using a (CA) array as the target for the screening; and vi) PCR analysis of lymphocytes for the presence of the BCL2 t(14:18) translocation. The relative merits of these molecular methods are discussed, and a comparison made with more "traditional" methods.

  2. A novel method for detection of apoptosis

    International Nuclear Information System (INIS)

    Zagariya, Alexander M.

    2012-01-01

    There are two different Angiotensin II (ANG II) peptides in nature: Human type (ANG II) and Bovine type (ANG II*). These eight amino acid peptides differ only at position 5 where Valine is replaced by Isoleucine in the Bovine type. They are present in all species studied so far. These amino acids are different by only one atom of carbon. This difference is so small, that it will allow any of ANG II, Bovine or Human antibodies to interact with all species and create a universal method for apoptosis detection. ANG II concentrations are found at substantially higher levels in apoptotic, compared to non-apoptotic, tissues. ANG II accumulation can lead to DNA damage, mutations, carcinogenesis and cell death. We demonstrate that Bovine antiserum can be used for universal detection of apoptosis. In 2010, the worldwide market for apoptosis detection reached the $20 billion mark and significantly increases each year. Most commercially available methods are related to Annexin V and TUNNEL. Our new method based on ANG II is more widely known to physicians and scientists compared to previously used methods. Our approach offers a novel alternative for assessing apoptosis activity with enhanced sensitivity, at a lower cost and ease of use.

  3. Doppler method leak detection for LMFBR steam generators. Pt. 1. Experimental results of bubble detection using small models

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi

    1999-01-01

    To prevent the expansion of the tube damage and to maintain structural integrity in the steam generators (SGs) of fast breeder reactors (FBRs), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method was developed. Previous studies have revealed that in practical steam generators the active acoustic method can detect bubbles of 10 l/s within 10 seconds. To prevent the expansion of damage to neighboring tubes, it is necessary to detect smaller leakages of water from the heat transfer tubes. The Doppler method is designed to detect small leakages and to find the source of the leak before damage spreads to neighboring tubes. To evaluate the relationship between the detection sensitivity of the Doppler method and the bubble volume and bubble size, the structural shapes and bubble flow conditions were investigated experimentally, using a small structural model. The results show that the Doppler method can detect the bubbles under bubble flow conditions, and it is sensitive enough to detect small leakages within a short time. The doppler method thus has strong potential for the detection of water leakage in SGs. (author)

  4. A Novel Fusion-Based Ship Detection Method from Pol-SAR Images

    Directory of Open Access Journals (Sweden)

    Wenguang Wang

    2015-09-01

    Full Text Available A novel fusion-based ship detection method from polarimetric Synthetic Aperture Radar (Pol-SAR images is proposed in this paper. After feature extraction and constant false alarm rate (CFAR detection, the detection results of HH channel, diplane scattering by Pauli decomposition and helical factor by Barnes decomposition are fused together. The confirmed targets and potential target pixels can be obtained after the fusion process. Using the difference degree of the target, potential target pixels can be classified. The fusion-based ship detection method works accurately by utilizing three different features comprehensively. The result of applying the technique to measured Airborne Synthetic Radar (AIRSAR data shows that the novel detection method can achieve better performance in both ship’s detection and ship’s shape preservation compared to the result of K-means clustering method and the Notch Filter method.

  5. Novel Methods of Hydrogen Leak Detection

    International Nuclear Information System (INIS)

    Pushpinder S Puri

    2006-01-01

    For hydrogen to become a consumer fuel for automotive and domestic power generation, safety is paramount. Today's hydrogen systems are built with inherent safety measures and multiple levels of protection. However, human senses, in particular, the sense of smell, is considered the ultimate safeguards against leaks. Since hydrogen is an odorless gas, use of odorants to detect leaks, as is done in case of natural gas, is obvious solution. The odorants required for hydrogen used in fuel cells have a unique requirement which must be met. This is because almost all of the commercial odorants used in gas leak detection contain sulfur which acts as poison for the catalysts used in hydrogen based fuel cells, most specifically for the PEM (polymer electrolyte membrane or proton exchange membrane) fuel cells. A possible solution to this problem is to use non-sulfur containing odorants. Chemical compounds based on mixtures of acrylic acid and nitrogen compounds have been adopted to achieve a sulfur-free odorization of a gas. It is, therefore, desired to have a method and system for hydrogen leak detection using odorant which can incorporate a uniform concentration of odorant in the hydrogen gas, when odorants are mixed in the hydrogen storage or delivery means. It is also desired to develop methods where the odorant is not added to the bulk hydrogen, keeping it free of the odorization additives. A series of novel solutions are proposed which address the issues raised above. These solutions are divided into three categories as follows: 1. Methods incorporating an odorant in the path of hydrogen leak as opposed to adding it to the hydrogen gas. 2. Methods where odorants are generated in-situ by chemical reaction with the leaking hydrogen 3. Methods of dispensing and storing odorants in high pressure hydrogen gas which release odorants to the gas at a uniform and predetermined rates. Use of one or more of the methods described here in conjunction with appropriate engineering

  6. Prenatal cigarette smoke exposure: Pregnancy outcome and gestational changes in plasma nicotine concentration, hematocrit, and carboxyhemoglobin in a newly standardized rat model

    International Nuclear Information System (INIS)

    Farkas, Svetlana; Hussein, Jabeen; Ariano, Robert E.; Sitar, Daniel S.; Hasan, Shabih U.

    2006-01-01

    Epidemiological studies support an association between perinatal cigarette smoke (CS) exposure and a number of severe pre- and postnatal complications. However, the mechanisms through which CS enhances such risks largely remain unknown. One of the reasons for our inability to discover such mechanisms has been the unavailability of a clinically relevant and physiologically concordant animal model. A number of studies have previously used nicotine (Nic) as surrogate for CS. We sought to (1) establish the amount of CS exposure to achieve plasma Nic concentrations observed among moderate to heavy smokers (20-60 ng/ml) (2) investigate the temporal changes in plasma Nic concentrations, carboxyhemoglobin, and hematocrit with advancing pregnancy, and (3) elucidate the effects of CS exposure on pregnancy outcome. Pregnant Sprague-Dawley rats were exposed to various doses of CS or room air (Sham) from days 6 to 21 of gestation. Exposure to 6000 ml/day of CS led to very high plasma Nic concentrations and increased maternal and fetal mortality (P < 0.001). The plasma Nic concentrations remained higher than those observed in moderate smokers until the CS dose was reduced to 1000 ml/day and showed dose-dependent temporal changes with advancing gestational age. Significant increases in carboxyhemoglobin and hematocrit were observed in the CS group as compared with the Sham group (P < 0.001). In addition, prenatally CS exposed fetuses had lower birth weight as compared with the Sham group (P = 0.04). Our current study establishes a newly standardized and physiologically relevant model to investigate the mechanisms of CS-mediated adverse effects during the critical period of fetal development

  7. Locally Sustainable School Lunch Intervention Improves Hemoglobin and Hematocrit Levels and Body Mass Index among Elementary Schoolchildren in Rural West Java, Indonesia.

    Science.gov (United States)

    Sekiyama, Makiko; Roosita, Katrin; Ohtsuka, Ryutaro

    2017-08-12

    School lunch is not provided in public elementary schools in Indonesia, and students frequently buy and eat snacks at school. We hypothesized that providing a traditional Sundanese meal as school lunch would be beneficial for children in rural West Java. To test this hypothesis, we evaluated the effect of a 1-month school lunch intervention aiming at sustainability and based on children's nutritional intake, hemoglobin and hematocrit levels, and body mass index (BMI). A lunch (including rice, vegetable dish, animal protein dish, plant protein dish, and fruit) containing one-third of the recommended daily allowance of energy was offered every school day for 1 month, targeting 68 fourth-grade elementary schoolchildren. At baseline, the prevalence of anemia was 33.3%. The prevalence of stunting and underweight were 32.4% and 2.9%, respectively, whereas that of overweight and obesity combined was 17.6%, indicating a double burden of malnutrition among the subjects. During the intervention, intakes of protein ( p < 0.05), calcium ( p < 0.05), and vitamin C ( p < 0.001) significantly increased, while that of fat significantly decreased ( p < 0.001). After the intervention, hemoglobin ( p < 0.05) and hematocrit ( p < 0.05) levels were significantly improved, thereby almost halving the rate of anemia. These changes were significantly larger in the baseline anemic group than the non-anemic group ( p < 0.01). BMI significantly increased in the baseline underweight/normal group ( p < 0.001) but not in the overweight/obese group. The school lunch intervention significantly improved nutritional intakes and health statuses, implying its potential for reducing anemia and resolving the double burden of malnutrition among rural Indonesian schoolchildren.

  8. Diferencias entre la hemoglobina observada y estimada por hematocrito y su importancia en el diagnóstico de anemia en población costera venezolana: análisis del segundo estudio nacional de crecimiento y desarrollo humano (SENACREDH Differences between observed and estimated by hematocrit hemoglobin and its relevance in the diagnosis of anemia among coastal population in Venezuela: analysis of the second national study of human growth and development (SENACREDH

    Directory of Open Access Journals (Sweden)

    Jessica Flores-Torres

    2011-03-01

    Full Text Available Objetivos. Evaluar las diferencias entre el valor de hemoglobina observada y el valor estimado a partir del hematocrito en el marco del Segundo Estudio Nacional de Crecimiento y Desarrollo Humano de la Población Venezolana (SENACREDH en el eje centro norte costero del país. Materiales y métodos. Por medio de un muestreo probabilístico multietápico por conglomerados se seleccionó un total de 6004 sujetos que representan 7 286 781 habitantes del eje Centro Norte Costero (Vargas, Carabobo, Distrito Capital, Aragua y Miranda. Se compararon medias de la hemoglobina observada y hemoglobina estimada (hematocrito/3, usando la prueba t para muestras relacionadas. Se realizaron regresiones lineales entre hemoglobina observada y hematocrito. Resultados. Se observó que el promedio de las diferencias entre la asignadas a la hemoglobina observada y la estimada por el hematocrito fue de -0,3446 ± 0,0002 (pObjectives. To evaluate the differences between the observed hemoglobin levels and those estimated based on hematocrit in the context of the 2nd National Study of Human Growth and Development of the Venezuelan Population (SENACREDH. Materials and methods. 6,004 individuals were chosen by a probabilistic multistage cluster sampling representing 7,286,781 inhabitants from North Central Coastal area (Vargas, Carabobo, Capital District, Aragua and Miranda. Means of observed and estimated hemoglobin (hematocrit/3 were compared, using t test for related samples and linear regression. Results. Mean difference between the values of observed and estimated hemoglobin was -0.3446 ±0.0002 (p<0.001; significantly overestimating the hemoglobin values. Regression models of hemoglobin on hematocrit showed an r2=0,87. In order to correct the estimation, we propose a new formula for calculating hemoglobin based on haematocrit values: estimated hemoglobin=(Haematocrit/3.135+ 0.257. Conclusions: There is an overestimation of hemoglobin levels from hematocrit levels and

  9. Soybean allergen detection methods--a comparison study

    DEFF Research Database (Denmark)

    Pedersen, M. Højgaard; Holzhauser, T.; Bisson, C.

    2008-01-01

    Soybean containing products are widely consumed, thus reliable methods for detection of soy in foods are needed in order to make appropriate risk assessment studies to adequately protect soy allergic patients. Six methods were compared using eight food products with a declared content of soy...

  10. Application of flaw detection methods for detection of fatigue processes in low-alloyed steel

    Directory of Open Access Journals (Sweden)

    Zbigniew H. śUREK

    2007-01-01

    Full Text Available The paper presents the investigations conducted in the Fraunhofer Institute (IZFP Saarbrücken by use of a BEMI microscope (BEMI= Barkhausenrausch- und Wirbelstrom-Mikroskopie or Barkhausen Noise and Eddy Current Microscopy. The ability to detect cyclic and contact fatigue load influences has been investigated. The measurement amplitudes obtained with Barkhausen Noise and Eddy Current probes havebeen analysed. Correlation of measurement results and material’s condition has been observed in case of the eddy current mode method for frequencies above 2 MHz (for contact-loaded material samples. Detection of material’s fatigue process (at 80 % fatiguelife in the sample subjected to series of high-cyclic loads has been proven to be practically impossible. Application of flaw detection methods in material fatigue tests requires modification of test methods and use of investigation methods relevant to physical parameters of the investigated material. The magnetic leakage field method, which has been abandoned by many researchers, may be of significant use in the material fatigue assessment and may provide new research prospects.

  11. Z-scores-based methods and their application to biological monitoring: an example in professional soccer players.

    Science.gov (United States)

    Saulière, Guillaume; Dedecker, Jérôme; Marquet, Laurie-Anne; Rochcongar, Pierre; Toussaint, Jean-Francois; Berthelot, Geoffroy

    2017-11-15

    The clinical and biological follow-up of individuals, such as the biological passport for athletes, is typically based on the individual and longitudinal monitoring of hematological or urine markers. These follow-ups aim to identify abnormal behavior by comparing the individual's biological samples to an established baseline. These comparisons may be done via different ways, but each of them requires an appropriate extra population to compute the significance levels, which is a non-trivial issue. Moreover, it is not necessarily relevant to compare the measures of a biomarker of a professional athlete to that of a reference population (even restricted to other athletes), and a reasonable alternative is to detect the abnormal values by considering only the other measurements of the same athlete. Here we propose a simple adaptive statistic based on maxima of Z-scores that does not rely on the use of an extra population. We show that, in the Gaussian framework, it is a practical and relevant method for detecting abnormal values in a series of observations from the same individual. The distribution of this statistic does not depend on the individual parameters under the null hypothesis, and its quantiles can be computed using Monte Carlo simulations. The proposed method is tested on the 3-year follow-up of ferritin, serum iron, erythrocytes, hemoglobin, and hematocrit markers in 2577 elite male soccer players. For instance, if we consider the abnormal values for the hematocrit at a 5% level, we found that 5.57% of the selected cohort had at least one abnormal value (which is not significantly different from the expected false-discovery rate). The approach is a starting point for more elaborate models that would produce a refined individual baseline. The method can be extended to the Gaussian linear model, in order to include additional variables such as the age or exposure to altitude. The method could also be applied to other domains, such as the clinical patient

  12. Detection methods for irradiated foods: current status. Proceedings

    International Nuclear Information System (INIS)

    McMurray, C.H.; Gray, R.; Stewart, E.M.; Pearce, J.; Queen's Univ., Belfast, Northern Ireland

    1996-01-01

    This book contains a scientific record of an international meeting on analytical detection methods for irradiation treatment of food. Apart from encouraging the basic development of detection tests, the meeting also aimed to assess the various test methods critically to determine their suitability for general use by public health laboratories and others concerned with trade in irradiated food. Two sets of criteria have been developed to assess test methods, technical criteria for a qualitative or quantitative test and practical criteria if a method is to be widely applied by food labelling authorities. Agreement has already been achieved for the use of electron spin resonance, thermoluminescence, hydrocarbons, 2-Alkylcyclobutanones, microbiological, viscometry and impedance tests. (UK)

  13. Localized surface plasmon resonance mercury detection system and methods

    Science.gov (United States)

    James, Jay; Lucas, Donald; Crosby, Jeffrey Scott; Koshland, Catherine P.

    2016-03-22

    A mercury detection system that includes a flow cell having a mercury sensor, a light source and a light detector is provided. The mercury sensor includes a transparent substrate and a submonolayer of mercury absorbing nanoparticles, e.g., gold nanoparticles, on a surface of the substrate. Methods of determining whether mercury is present in a sample using the mercury sensors are also provided. The subject mercury detection systems and methods find use in a variety of different applications, including mercury detecting applications.

  14. A high-throughput multiplex method adapted for GMO detection.

    Science.gov (United States)

    Chaouachi, Maher; Chupeau, Gaëlle; Berard, Aurélie; McKhann, Heather; Romaniuk, Marcel; Giancola, Sandra; Laval, Valérie; Bertheau, Yves; Brunel, Dominique

    2008-12-24

    A high-throughput multiplex assay for the detection of genetically modified organisms (GMO) was developed on the basis of the existing SNPlex method designed for SNP genotyping. This SNPlex assay allows the simultaneous detection of up to 48 short DNA sequences (approximately 70 bp; "signature sequences") from taxa endogenous reference genes, from GMO constructions, screening targets, construct-specific, and event-specific targets, and finally from donor organisms. This assay avoids certain shortcomings of multiplex PCR-based methods already in widespread use for GMO detection. The assay demonstrated high specificity and sensitivity. The results suggest that this assay is reliable, flexible, and cost- and time-effective for high-throughput GMO detection.

  15. Recent developments in optical detection methods for microchip separations

    NARCIS (Netherlands)

    Götz, S.; Karst, U.

    2007-01-01

    This paper summarizes the features and performances of optical detection systems currently applied in order to monitor separations on microchip devices. Fluorescence detection, which delivers very high sensitivity and selectivity, is still the most widely applied method of detection. Instruments

  16. Fault detection of gearbox using time-frequency method

    Science.gov (United States)

    Widodo, A.; Satrijo, Dj.; Prahasto, T.; Haryanto, I.

    2017-04-01

    This research deals with fault detection and diagnosis of gearbox by using vibration signature. In this work, fault detection and diagnosis are approached by employing time-frequency method, and then the results are compared with cepstrum analysis. Experimental work has been conducted for data acquisition of vibration signal thru self-designed gearbox test rig. This test-rig is able to demonstrate normal and faulty gearbox i.e., wears and tooth breakage. Three accelerometers were used for vibration signal acquisition from gearbox, and optical tachometer was used for shaft rotation speed measurement. The results show that frequency domain analysis using fast-fourier transform was less sensitive to wears and tooth breakage condition. However, the method of short-time fourier transform was able to monitor the faults in gearbox. Wavelet Transform (WT) method also showed good performance in gearbox fault detection using vibration signal after employing time synchronous averaging (TSA).

  17. An operant-based detection method for inferring tinnitus in mice.

    Science.gov (United States)

    Zuo, Hongyan; Lei, Debin; Sivaramakrishnan, Shobhana; Howie, Benjamin; Mulvany, Jessica; Bao, Jianxin

    2017-11-01

    Subjective tinnitus is a hearing disorder in which a person perceives sound when no external sound is present. It can be acute or chronic. Because our current understanding of its pathology is incomplete, no effective cures have yet been established. Mouse models are useful for studying the pathophysiology of tinnitus as well as for developing therapeutic treatments. We have developed a new method for determining acute and chronic tinnitus in mice, called sound-based avoidance detection (SBAD). The SBAD method utilizes one paradigm to detect tinnitus and another paradigm to monitor possible confounding factors, such as motor impairment, loss of motivation, and deficits in learning and memory. The SBAD method has succeeded in monitoring both acute and chronic tinnitus in mice. Its detection ability is further validated by functional studies demonstrating an abnormal increase in neuronal activity in the inferior colliculus of mice that had previously been identified as having tinnitus by the SBAD method. The SBAD method provides a new means by which investigators can detect tinnitus in a single mouse accurately and with more control over potential confounding factors than existing methods. This work establishes a new behavioral method for detecting tinnitus in mice. The detection outcome is consistent with functional validation. One key advantage of mouse models is they provide researchers the opportunity to utilize an extensive array of genetic tools. This new method could lead to a deeper understanding of the molecular pathways underlying tinnitus pathology. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Reliably detectable flaw size for NDE methods that use calibration

    Science.gov (United States)

    Koshti, Ajay M.

    2017-04-01

    Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-1823 and associated mh18232 POD software gives most common methods of POD analysis. In this paper, POD analysis is applied to an NDE method, such as eddy current testing, where calibration is used. NDE calibration standards have known size artificial flaws such as electro-discharge machined (EDM) notches and flat bottom hole (FBH) reflectors which are used to set instrument sensitivity for detection of real flaws. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. Therefore, it is important to correlate signal responses from real flaws with signal responses form artificial flaws used in calibration process to determine reliably detectable flaw size.

  19. Metric Learning Method Aided Data-Driven Design of Fault Detection Systems

    Directory of Open Access Journals (Sweden)

    Guoyang Yan

    2014-01-01

    Full Text Available Fault detection is fundamental to many industrial applications. With the development of system complexity, the number of sensors is increasing, which makes traditional fault detection methods lose efficiency. Metric learning is an efficient way to build the relationship between feature vectors with the categories of instances. In this paper, we firstly propose a metric learning-based fault detection framework in fault detection. Meanwhile, a novel feature extraction method based on wavelet transform is used to obtain the feature vector from detection signals. Experiments on Tennessee Eastman (TE chemical process datasets demonstrate that the proposed method has a better performance when comparing with existing methods, for example, principal component analysis (PCA and fisher discriminate analysis (FDA.

  20. Novel Fingertip Image-Based Heart Rate Detection Methods for a Smartphone

    Directory of Open Access Journals (Sweden)

    Rifat Zaman

    2017-02-01

    Full Text Available We hypothesize that our fingertip image-based heart rate detection methods using smartphone reliably detect the heart rhythm and rate of subjects. We propose fingertip curve line movement-based and fingertip image intensity-based detection methods, which both use the movement of successive fingertip images obtained from smartphone cameras. To investigate the performance of the proposed methods, heart rhythm and rate of the proposed methods are compared to those of the conventional method, which is based on average image pixel intensity. Using a smartphone, we collected 120 s pulsatile time series data from each recruited subject. The results show that the proposed fingertip curve line movement-based method detects heart rate with a maximum deviation of 0.0832 Hz and 0.124 Hz using time- and frequency-domain based estimation, respectively, compared to the conventional method. Moreover, another proposed fingertip image intensity-based method detects heart rate with a maximum deviation of 0.125 Hz and 0.03 Hz using time- and frequency-based estimation, respectively.

  1. Dynamic baseline detection method for power data network service

    Science.gov (United States)

    Chen, Wei

    2017-08-01

    This paper proposes a dynamic baseline Traffic detection Method which is based on the historical traffic data for the Power data network. The method uses Cisco's NetFlow acquisition tool to collect the original historical traffic data from network element at fixed intervals. This method uses three dimensions information including the communication port, time, traffic (number of bytes or number of packets) t. By filtering, removing the deviation value, calculating the dynamic baseline value, comparing the actual value with the baseline value, the method can detect whether the current network traffic is abnormal.

  2. Human Detection System by Fusing Depth Map-Based Method and Convolutional Neural Network-Based Method

    Directory of Open Access Journals (Sweden)

    Anh Vu Le

    2017-01-01

    Full Text Available In this paper, the depth images and the colour images provided by Kinect sensors are used to enhance the accuracy of human detection. The depth-based human detection method is fast but less accurate. On the other hand, the faster region convolutional neural network-based human detection method is accurate but requires a rather complex hardware configuration. To simultaneously leverage the advantages and relieve the drawbacks of each method, one master and one client system is proposed. The final goal is to make a novel Robot Operation System (ROS-based Perception Sensor Network (PSN system, which is more accurate and ready for the real time application. The experimental results demonstrate the outperforming of the proposed method compared with other conventional methods in the challenging scenarios.

  3. Rubella virus detection by ELISA method in exposed radiation workers

    International Nuclear Information System (INIS)

    Wu Jianmei; Zhu Bo; Zhu Youming; Shao Jinhui; Wu Weiping; Han Jinxiang

    2005-01-01

    Objective: A rapid diagnosis method was developed to detect Rubella virus infection in radiation workers. Methods: Modified ELISA method was used to detect the level of lgG and lgM antibodies in 514 in Jinan district. Results: 90.47% of 514 cases was shown to be resistant against Rubella virus; 6.42% were sensitive type; 0.78% belonged to be reinfected. Conclusion: Detection of Rubella virus in exposed radiation workers was imperative, and vaccine against Rubella virus was also needed to eliminate the infection risk. (authors)

  4. Detection method of a failed fuel

    International Nuclear Information System (INIS)

    Urata, Megumu; Uchida, Shunsuke; Utamura, Motoaki.

    1976-01-01

    Object: To divide a tank arrangement into a heating tank for the exclusive use of heating and a mixing tank for the exclusive use of mixing to thereby minimize the purifying amount of reactor water pumped from the interior of reactor and to considerably minimize the capacity of a purifier. Structure: In a detection method of a failed fuel comprising stopping a flow of coolant within fuel assemblies arranged in the coolant in a reactor container, sampling said coolant within the fuel assemblies, and detecting a radioactivity level of sampling liquid, the improvement of the method comprising the steps of heating a part of said coolant removed from the interior of said reactor container, mixing said heated coolant into the remainder of said removed coolant, pouring said mixed liquid into said fuel assemblies, and after a lapse of given time, sampling the liquid poured into said fuel assemblies. (Kawakami, Y.)

  5. Method for detecting a failed fuel

    International Nuclear Information System (INIS)

    Utamura, Motoaki; Urata, Megumu; Uchida, Shunsuke.

    1976-01-01

    Purpose: To provide a method for the detection of failed fuel by pouring hot water, in which pouring speed of liquid to be poured and temperature of the liquid are controlled to prevent the leakage of the liquid. Constitution: The method comprises blocking the top of a fuel assembly arranged in coolant to stop a flow of coolant, pouring a liquid higher in temperature than that of coolant into the fuel assembly, sampling the liquid poured, and measuring the concentration of radioactivity of coolant already subjected to sampling to detect a failed fuel. At this time, controlling is made so that the pouring speed of the poured liquid is set to about 25 l/min, and an increased portion of temperature from the temperature of liquid to the temperature of coolant is set to a level less than about 15 0 C. (Furukawa, Y.)

  6. Method of detecting genetic deletions identified with chromosomal abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Joe W; Pinkel, Daniel; Tkachuk, Douglas

    2013-11-26

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyzes. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acids probes are typically of a complexity greater tha 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particlularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar ut genetically different diseases, and for many prognostic and diagnostic applications.

  7. Detection of irradiated foods by the DEFT/APC method

    International Nuclear Information System (INIS)

    Yuecel, P. K.; Koeseoglu, T.; Halkman, H. B. D.

    2009-01-01

    Irradiation technology is used to prevent the spoilage losses and to improve the hygienic quality of foods. Appropriate techniques for the detection of irradiated foods are needed to guarantee the proper consumer information and to facilitate the trade of irradiated foods. The characteristics of the microbial population of irradiated foods have been used for developing detection methods for irradiated foods. This microbiological method is based on the comparison of an aerobic plate count (APC) with a count obtained with the direct epifluorescent filter technique (DEFT) for the detection of irradiation of foodstuffs.

  8. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kitajima, Akira; Suzuki, Akio.

    1990-01-01

    The objective of this study is to estimate the feasibility of the acoustic method for the internal leakage from the valves in power plants. From the experimental results, it was suggested that the acoustic method for the monitoring of leakage was feasible. When the background levels are higher than the acoustic signals from leakage, we can detect the leakage analyzing the spectrum of the remainders which take the background noise from the acoustic signals. (author)

  9. Method of Detecting Coliform Bacteria from Reflected Light

    Science.gov (United States)

    Vincent, Robert K. (Inventor)

    2014-01-01

    The present invention relates to a method of detecting coliform bacteria in water from reflected light, and also includes devices for the measurement, calculation and transmission of data relating to that method.

  10. Real-Time Pore Pressure Detection: Indicators and Improved Methods

    Directory of Open Access Journals (Sweden)

    Jincai Zhang

    2017-01-01

    Full Text Available High uncertainties may exist in the predrill pore pressure prediction in new prospects and deepwater subsalt wells; therefore, real-time pore pressure detection is highly needed to reduce drilling risks. The methods for pore pressure detection (the resistivity, sonic, and corrected d-exponent methods are improved using the depth-dependent normal compaction equations to adapt to the requirements of the real-time monitoring. A new method is proposed to calculate pore pressure from the connection gas or elevated background gas, which can be used for real-time pore pressure detection. The pore pressure detection using the logging-while-drilling, measurement-while-drilling, and mud logging data is also implemented and evaluated. Abnormal pore pressure indicators from the well logs, mud logs, and wellbore instability events are identified and analyzed to interpret abnormal pore pressures for guiding real-time drilling decisions. The principles for identifying abnormal pressure indicators are proposed to improve real-time pore pressure monitoring.

  11. Various imaging methods in the detection of small hepatomas

    International Nuclear Information System (INIS)

    Nakatsuka, Haruki; Kaminou, Toshio; Takemoto, Kazumasa; Takashima, Sumio; Kobayashi, Nobuyuki; Nakamura, Kenji; Onoyama, Yasuto; Kurioka, Naruto

    1985-01-01

    Fifty-one patients with small hepatomas under 5 cm in diameter were studied to compare the detectability of various imaging methods. Positive finding was obtained in 50 % of the patients by scintigraphy, in 74 % by ultrasonography and in 79 % by CT during screening tests. Rate of detection in retrospective analysis, after the site of the tumor had been known, were 73 %, 93 % and 87 % respectively. Rate of detection was 92 % by celiac arteriography and 98 % by selective hepatic arteriography. In 21 patients, who had the tumor under 3 cm, the rate was 32 % for scintigraphy, 74 % for ultrasonography and 65 % for CT during screening, whereas it was 58 %, 84 % and 75 % retrospectively. By celiac arteriography, it was 85 %, and by hepatic arteriography, 95 %. Rate of detection of small hepatomas in screening tests differed remarkably from that in retrospective analysis. No single method of imaging can disclose reliably the presense of small hepatoma, therefore more than one method should be used in screening. (author)

  12. Bayesian Methods for Radiation Detection and Dosimetry

    CERN Document Server

    Groer, Peter G

    2002-01-01

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed comp...

  13. Sunglass detection method for automation of video surveillance system

    Science.gov (United States)

    Sikandar, Tasriva; Samsudin, Wan Nur Azhani W.; Hawari Ghazali, Kamarul; Mohd, Izzeldin I.; Fazle Rabbi, Mohammad

    2018-04-01

    Wearing sunglass to hide face from surveillance camera is a common activity in criminal incidences. Therefore, sunglass detection from surveillance video has become a demanding issue in automation of security systems. In this paper we propose an image processing method to detect sunglass from surveillance images. Specifically, a unique feature using facial height and width has been employed to identify the covered region of the face. The presence of covered area by sunglass is evaluated using facial height-width ratio. Threshold value of covered area percentage is used to classify the glass wearing face. Two different types of glasses have been considered i.e. eye glass and sunglass. The results of this study demonstrate that the proposed method is able to detect sunglasses in two different illumination conditions such as, room illumination as well as in the presence of sunlight. In addition, due to the multi-level checking in facial region, this method has 100% accuracy of detecting sunglass. However, in an exceptional case where fabric surrounding the face has similar color as skin, the correct detection rate was found 93.33% for eye glass.

  14. Sensing Methods for Detecting Analog Television Signals

    Science.gov (United States)

    Rahman, Mohammad Azizur; Song, Chunyi; Harada, Hiroshi

    This paper introduces a unified method of spectrum sensing for all existing analog television (TV) signals including NTSC, PAL and SECAM. We propose a correlation based method (CBM) with a single reference signal for sensing any analog TV signals. In addition we also propose an improved energy detection method. The CBM approach has been implemented in a hardware prototype specially designed for participating in Singapore TV white space (WS) test trial conducted by Infocomm Development Authority (IDA) of the Singapore government. Analytical and simulation results of the CBM method will be presented in the paper, as well as hardware testing results for sensing various analog TV signals. Both AWGN and fading channels will be considered. It is shown that the theoretical results closely match with those from simulations. Sensing performance of the hardware prototype will also be presented in fading environment by using a fading simulator. We present performance of the proposed techniques in terms of probability of false alarm, probability of detection, sensing time etc. We also present a comparative study of the various techniques.

  15. Small Displacement Detection of Biological Signals Using the Cyclic Frequency Method

    Directory of Open Access Journals (Sweden)

    Dan Zhang

    2015-01-01

    Full Text Available A new signal processing method called the Cyclic Frequency method is proposed for small displacement detection of vital signals such as heart rate and respiration using the CW radar method. We have presented experimental results of small displacement detection to confirm the validity of the method. The displacement amplitude 2.5 mm can be detected with a propagation frequency of 24.15 GHz. We may increase the propagation frequency for smaller displacement amplitude or target velocity.

  16. Molecular detection methods of resistance to antituberculosis drugs in Mycobacterium tuberculosis.

    Science.gov (United States)

    Brossier, F; Sougakoff, W

    2017-09-01

    Molecular methods predict drug resistance several weeks before phenotypic methods and enable rapid implementation of appropriate therapeutic treatment. We aimed to detail the most representative molecular tools used in routine practice for the rapid detection of resistance to antituberculosis drugs among Mycobacterium tuberculosis strains. The molecular diagnosis of resistance to antituberculosis drugs in clinical samples or from in vitro cultures is based on the detection of the most common mutations in the genes involved in the development of resistance in M. tuberculosis strains (encoding either protein targets of antibiotics, or antibiotic activating enzymes) by commercial molecular kits or by sequencing. Three hypotheses could explain the discrepancies between the genotypic results and the phenotypic drug susceptibility testing results: a low percentage of resistant mutants precluding the detection by genotypic methods on the primary culture; a low level of resistance not detected by phenotypic testing; and other resistance mechanisms not yet characterized. Molecular methods have varying sensitivity with regards to detecting antituberculosis drug resistance; that is why phenotypic susceptibility testing methods are mandatory for detecting antituberculosis drug-resistant isolates that have not been detected by molecular methods. The questionable ability of existing phenotypic and genotypic drug susceptibility testing to properly classify strains as susceptible or resistant, and at what level of resistance, was raised for several antituberculosis agents. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Automated Detection of Salt Marsh Platforms : a Topographic Method

    Science.gov (United States)

    Goodwin, G.; Mudd, S. M.; Clubb, F. J.

    2017-12-01

    Monitoring the topographic evolution of coastal marshes is a crucial step toward improving the management of these valuable landscapes under the pressure of relative sea level rise and anthropogenic modification. However, determining their geometrically complex boundaries currently relies on spectral vegetation detection methods or requires labour-intensive field surveys and digitisation.We propose a novel method to reproducibly isolate saltmarsh scarps and platforms from a DEM. Field observations and numerical models show that saltmarshes mature into sub-horizontal platforms delineated by sub-vertical scarps: based on this premise, we identify scarps as lines of local maxima on a slope*relief raster, then fill landmasses from the scarps upward, thus isolating mature marsh platforms. Non-dimensional search parameters allow batch-processing of data without recalibration. We test our method using lidar-derived DEMs of six saltmarshes in England with varying tidal ranges and geometries, for which topographic platforms were manually isolated from tidal flats. Agreement between manual and automatic segregation exceeds 90% for resolutions of 1m, with all but one sites maintaining this performance for resolutions up to 3.5m. For resolutions of 1m, automatically detected platforms are comparable in surface area and elevation distribution to digitised platforms. We also find that our method allows the accurate detection of local bloc failures 3 times larger than the DEM resolution.Detailed inspection reveals that although tidal creeks were digitised as part of the marsh platform, automatic detection classifies them as part of the tidal flat, causing an increase in false negatives and overall platform perimeter. This suggests our method would benefit from a combination with existing creek detection algorithms. Fallen blocs and pioneer zones are inconsistently identified, particularly in macro-tidal marshes, leading to differences between digitisation and the automated method

  18. Method development of damage detection in asymmetric buildings

    Science.gov (United States)

    Wang, Yi; Thambiratnam, David P.; Chan, Tommy H. T.; Nguyen, Andy

    2018-01-01

    Aesthetics and functionality requirements have caused most buildings to be asymmetric in recent times. Such buildings exhibit complex vibration characteristics under dynamic loads as there is coupling between the lateral and torsional components of vibration, and are referred to as torsionally coupled buildings. These buildings require three dimensional modelling and analysis. In spite of much recent research and some successful applications of vibration based damage detection methods to civil structures in recent years, the applications to asymmetric buildings has been a challenging task for structural engineers. There has been relatively little research on detecting and locating damage specific to torsionally coupled asymmetric buildings. This paper aims to compare the difference in vibration behaviour between symmetric and asymmetric buildings and then use the vibration characteristics for predicting damage in them. The need for developing a special method to detect damage in asymmetric buildings thus becomes evident. Towards this end, this paper modifies the traditional modal strain energy based damage index by decomposing the mode shapes into their lateral and vertical components and to form component specific damage indices. The improved approach is then developed by combining the modified strain energy based damage indices with the modal flexibility method which was modified to suit three dimensional structures to form a new damage indicator. The procedure is illustrated through numerical studies conducted on three dimensional five-story symmetric and asymmetric frame structures with the same layout, after validating the modelling techniques through experimental testing of a laboratory scale asymmetric building model. Vibration parameters obtained from finite element analysis of the intact and damaged building models are then applied into the proposed algorithms for detecting and locating the single and multiple damages in these buildings. The results

  19. Theoretical and numerical investigations into the SPRT method for anomaly detection

    International Nuclear Information System (INIS)

    Schoonewelle, H.; Hagen, T.H.J.J. van der; Hoogenboom, J.E.

    1995-01-01

    The sequential probability ratio test developed by Wald is a powerful method of testing an alternative hypothesis against a null hypothesis. This makes the method applicable for anomaly detection. In this paper the method is used to detect a change of the standard deviation of a Gaussian distributed white noise signal. The false alarm probability, the alarm failure probability and the average time to alarm of the method, which are important parameters for anomaly detection, are determined by simulation and compared with theoretical results. Each of the three parameters is presented in dependence of the other two and the ratio of the standard deviation of the anomalous signal and that of the normal signal. Results show that the method is very well suited for anomaly detection. It can detect for example a 50% change in standard deviation within 1 second with a false alarm and alarm failure rate of less than once per month. (author)

  20. Theoretical and numerical investigations into the SPRT method for anomaly detection

    Energy Technology Data Exchange (ETDEWEB)

    Schoonewelle, H.; Hagen, T.H.J.J. van der; Hoogenboom, J.E. [Interuniversitair Reactor Inst., Delft (Netherlands)

    1995-11-01

    The sequential probability ratio test developed by Wald is a powerful method of testing an alternative hypothesis against a null hypothesis. This makes the method applicable for anomaly detection. In this paper the method is used to detect a change of the standard deviation of a Gaussian distributed white noise signal. The false alarm probability, the alarm failure probability and the average time to alarm of the method, which are important parameters for anomaly detection, are determined by simulation and compared with theoretical results. Each of the three parameters is presented in dependence of the other two and the ratio of the standard deviation of the anomalous signal and that of the normal signal. Results show that the method is very well suited for anomaly detection. It can detect for example a 50% change in standard deviation within 1 second with a false alarm and alarm failure rate of less than once per month. (author).

  1. Research and Design of Rootkit Detection Method

    Science.gov (United States)

    Liu, Leian; Yin, Zuanxing; Shen, Yuli; Lin, Haitao; Wang, Hongjiang

    Rootkit is one of the most important issues of network communication systems, which is related to the security and privacy of Internet users. Because of the existence of the back door of the operating system, a hacker can use rootkit to attack and invade other people's computers and thus he can capture passwords and message traffic to and from these computers easily. With the development of the rootkit technology, its applications are more and more extensive and it becomes increasingly difficult to detect it. In addition, for various reasons such as trade secrets, being difficult to be developed, and so on, the rootkit detection technology information and effective tools are still relatively scarce. In this paper, based on the in-depth analysis of the rootkit detection technology, a new kind of the rootkit detection structure is designed and a new method (software), X-Anti, is proposed. Test results show that software designed based on structure proposed is much more efficient than any other rootkit detection software.

  2. Change-Point Detection Method for Clinical Decision Support System Rule Monitoring.

    Science.gov (United States)

    Liu, Siqi; Wright, Adam; Hauskrecht, Milos

    2017-06-01

    A clinical decision support system (CDSS) and its components can malfunction due to various reasons. Monitoring the system and detecting its malfunctions can help one to avoid any potential mistakes and associated costs. In this paper, we investigate the problem of detecting changes in the CDSS operation, in particular its monitoring and alerting subsystem, by monitoring its rule firing counts. The detection should be performed online, that is whenever a new datum arrives, we want to have a score indicating how likely there is a change in the system. We develop a new method based on Seasonal-Trend decomposition and likelihood ratio statistics to detect the changes. Experiments on real and simulated data show that our method has a lower delay in detection compared with existing change-point detection methods.

  3. Hough transform methods used for object detection

    International Nuclear Information System (INIS)

    Qussay A Salih; Abdul Rahman Ramli; Md Mahmud Hassan Prakash

    2001-01-01

    The Hough transform (HT) is a robust parameter estimator of multi-dimensional features in images. The HT is an established technique which evidences a shape by mapping image edge points into a parameter space. The HT is technique which is used to isolate curves of a give shape in an image. The classical HT requires that the curve be specified in some parametric from and, hence is most commonly used in the detection of regular curves. The HT has been generalized so that it is capable of detecting arbitrary curved shapes. The main advantage of this transform technique is that it is very tolerant of gaps in the actual object boundaries the classical HT for the detection of line , we will indicate how it can be applied to the detection of arbitrary shapes. Sometimes the straight line HT is efficient enough to detect features such as artificial curves. The HT is an established technique for extracting geometric shapes based on the duality definition of the points on a curve and their parameters. This technique has been developed for extracting simple geometric shapes such as lines, circles and ellipses as well as arbitrary shapes. The HT provides robustness against discontinuous or missing features, points or edges are mapped into a partitioned parameter of Hough space as individual votes where peaks denote the feature of interest represented in a non-analytically tabular form. The main drawback of the HT technique is the computational requirement which has an exponential growth of memory space and processing time as the number of parameters used to represent a primitive increases. For this reason most of the research on the HT has focused on reducing the computational burden for extracting of arbitrary shapes under more general transformations include a overview of describing the methods for the detection image processing programs are frequently required to detect and particle classification in an industrial setting, a standard algorithms for this detection lines

  4. A Review of the Detection Methods for Climate Regime Shifts

    Directory of Open Access Journals (Sweden)

    Qunqun Liu

    2016-01-01

    Full Text Available An abrupt climate change means that the climate system shifts from a steady state to another steady state. Study on the phenomenon and theory of the abrupt climate change is a new research field of modern climatology, and it is of great significance for the prediction of future climate change. The climate regime shift is one of the most common forms of abrupt climate change, which mainly refers to the statistical significant changes on the variable of climate system at one time scale. These detection methods can be roughly divided into five categories based on different types of abrupt changes, namely, abrupt mean value change, abrupt variance change, abrupt frequency change, abrupt probability density change, and the multivariable analysis. The main research progress of abrupt climate change detection methods is reviewed. What is more, some actual applications of those methods in observational data are provided. With the development of nonlinear science, many new methods have been presented for detecting an abrupt dynamic change in recent years, which is useful supplement for the abrupt change detection methods.

  5. Samsung Salmonella Detection Kit. AOAC Performance Tested Method(SM) 021203.

    Science.gov (United States)

    Li, Jun; Cheung, Win Den; Opdyke, Jason; Harvey, John; Chong, Songchun; Moon, Cheol Gon

    2012-01-01

    Salmonella, one of the most common causes of foodborne illness, is a significant public health concern worldwide. There is a need in the food industry for methods that are simple, rapid, and sensitive for the detection of foodborne pathogens. In this study, the Samsung Salmonella Detection Kit, a real-time PCR assay for the detection of Salmonella, was evaluated according to the current AOAC guidelines. The validation consisted of lot-to-lot consistency, stability, robustness, and inclusivity/exclusivity studies, as well as a method comparison of 10 different food matrixes. In the validation, the Samsung Salmonella Detection Kit was used in conjunction with the Applied Biosystems StepOnePlus PCR system and the Samsung Food Testing Software for the detection of Salmonella species. The performance of the assays was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) 4.05: Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish and the and U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference methods. The validation was conducted using an unpaired study design for detection of Salmonella spp. in raw ground beef, raw pork, raw ground pork, raw chicken wings, raw salmon, alfalfa sprouts, pasteurized orange juice, peanut butter, pasteurized whole milk, and shell eggs. The Samsung Salmonella Detection Kit demonstrated lot-to-lot consistency among three independent lots as well as ruggedness with minor modifications to changes in enrichment incubation time, enrichment incubation temperature, and DNA sample volume for PCR reaction. Stability was observed for 13 months at -20 degrees C and 3 months at 5 degrees C. For the inclusivity/exclusivity study, the Samsung Salmonella Detection Kit correctly identified 147 Salmonella species isolates out of 147 isolates tested from each of three different enrichment

  6. Recent developments in optical detection methods for microchip separations.

    Science.gov (United States)

    Götz, Sebastian; Karst, Uwe

    2007-01-01

    This paper summarizes the features and performances of optical detection systems currently applied in order to monitor separations on microchip devices. Fluorescence detection, which delivers very high sensitivity and selectivity, is still the most widely applied method of detection. Instruments utilizing laser-induced fluorescence (LIF) and lamp-based fluorescence along with recent applications of light-emitting diodes (LED) as excitation sources are also covered in this paper. Since chemiluminescence detection can be achieved using extremely simple devices which no longer require light sources and optical components for focusing and collimation, interesting approaches based on this technique are presented, too. Although UV/vis absorbance is a detection method that is commonly used in standard desktop electrophoresis and liquid chromatography instruments, it has not yet reached the same level of popularity for microchip applications. Current applications of UV/vis absorbance detection to microchip separations and innovative approaches that increase sensitivity are described. This article, which contains 85 references, focuses on developments and applications published within the last three years, points out exciting new approaches, and provides future perspectives on this field.

  7. Maternal hemoglobin concentration and hematocrit values may affect fetus development by influencing placental angiogenesis.

    Science.gov (United States)

    Stangret, Aleksandra; Wnuk, Anna; Szewczyk, Grzegorz; Pyzlak, Michał; Szukiewicz, Dariusz

    2017-01-01

    Vasculogenesis and angiogenesis are crucial for maintaining proper placental perfusion and optimal fetal development. Among other physical and chemical factors, hypoxia is known to stimulate angiogenic processes. Preplacental type of hypoxia is often associated with maternal anemia and is thought to enhance vascularization within the fetoplacental unit. The goal of this study was to establish the correlation between the local expression of vascular endothelial growth factor (VEGF) and placenta growth factor (PlGF) receptors (flt-1, flk-1) with maternal hemoglobin (Hb) concentration, hematocrit (Ht) values and the infant birthweight. In total, 43 specimens of term placentas obtained from normal course pregnancies delivered at term were included in the study. The expression of flt-1 and flk-1 receptors was analyzed by immunohistochemical staining. Vascular/extravascular tissular index (V/EVTI) was measured by assessing a total vascular area. Nonparametric Mann-Whitney U-test and Spearman's rank correlation were used to compare the various parameters and their differences between the groups. Among the patients with low Hb concentration, nearly 2-fold greater expression of the flt-1 receptor was positively correlated with infants birthweight (p = 0.028). Increased placental vascular density (increased flt-1 expression), during a physiological course of gestation, may be an adaptive response to lowered maternal Hb concentration and Ht values encountered during pregnancy.

  8. Novel Methods of Hydrogen Leak Detection

    International Nuclear Information System (INIS)

    Pushpinder S Puri

    2006-01-01

    With the advent of the fuel cell technology and a drive for clean fuel, hydrogen gas is emerging as a leading candidate for the fuel of choice. For hydrogen to become a consumer fuel for automotive and domestic power generation, safety is paramount. It is, therefore, desired to have a method and system for hydrogen leak detection using odorant which can incorporate a uniform concentration of odorant in the hydrogen gas, when odorants are mixed in the hydrogen storage or delivery means. It is also desired to develop methods where the odorant is not added to the bulk hydrogen, keeping it free of the odorization additives. When odorants are not added to the hydrogen gas in the storage or delivery means, methods must be developed to incorporate odorant in the leaking gas so that leaks can be detected by small. Further, when odorants are not added to the stored hydrogen, it may also be desirable to observe leaks by sight by discoloration of the surface of the storage or transportation vessels. A series of novel solutions are proposed which address the issues raised above. These solutions are divided into three categories as follows: 1. Methods incorporating an odorant in the path of hydrogen leak as opposed to adding it to the hydrogen gas. 2. Methods where odorants are generated in-situ by chemical reaction with the leaking hydrogen 3. Methods of dispensing and storing odorants in high pressure hydrogen gas which release odorants to the gas at a uniform and predetermined rates. Use of one or more of the methods described here in conjunction with appropriate engineering solutions will assure the ultimate safety of hydrogen use as a commercial fuel. (authors)

  9. [An automatic peak detection method for LIBS spectrum based on continuous wavelet transform].

    Science.gov (United States)

    Chen, Peng-Fei; Tian, Di; Qiao, Shu-Jun; Yang, Guang

    2014-07-01

    Spectrum peak detection in the laser-induced breakdown spectroscopy (LIBS) is an essential step, but the presence of background and noise seriously disturb the accuracy of peak position. The present paper proposed a method applied to automatic peak detection for LIBS spectrum in order to enhance the ability of overlapping peaks searching and adaptivity. We introduced the ridge peak detection method based on continuous wavelet transform to LIBS, and discussed the choice of the mother wavelet and optimized the scale factor and the shift factor. This method also improved the ridge peak detection method with a correcting ridge method. The experimental results show that compared with other peak detection methods (the direct comparison method, derivative method and ridge peak search method), our method had a significant advantage on the ability to distinguish overlapping peaks and the precision of peak detection, and could be be applied to data processing in LIBS.

  10. Statistical Methods for the detection of answer copying on achievement tests

    NARCIS (Netherlands)

    Sotaridona, Leonardo

    2003-01-01

    This thesis contains a collection of studies where statistical methods for the detection of answer copying on achievement tests in multiple-choice format are proposed and investigated. Although all methods are suited to detect answer copying, each method is designed to address specific

  11. Fast Detection Method in Cooperative Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    Zhengyi Li

    2010-01-01

    Full Text Available Cognitive Radio (CR technology improves the utilization of spectrum highly via opportunistic spectrum sharing, which requests fast detection as the spectrum utilization is dynamic. Taking into consideration the characteristic of wireless channels, we propose a fast detection scheme for a cooperative cognitive radio network, which consists of multiple CRs and a central control office. Specifically, each CR makes individual detection decision using the sequential probability ratio test combined with Neyman Pearson detection with respect to a specific observation window length. The proposed method upper bounds the detection delay. In addition, a weighted K out of N fusion rule is also proposed for the central control office to reach fast global decision based on the information collected from CRs, with more weights assigned for CRs with good channel conditions. Simulation results show that the proposed scheme can achieve fast detection while maintaining the detection accuracy.

  12. A novel visual saliency detection method for infrared video sequences

    Science.gov (United States)

    Wang, Xin; Zhang, Yuzhen; Ning, Chen

    2017-12-01

    Infrared video applications such as target detection and recognition, moving target tracking, and so forth can benefit a lot from visual saliency detection, which is essentially a method to automatically localize the ;important; content in videos. In this paper, a novel visual saliency detection method for infrared video sequences is proposed. Specifically, for infrared video saliency detection, both the spatial saliency and temporal saliency are considered. For spatial saliency, we adopt a mutual consistency-guided spatial cues combination-based method to capture the regions with obvious luminance contrast and contour features. For temporal saliency, a multi-frame symmetric difference approach is proposed to discriminate salient moving regions of interest from background motions. Then, the spatial saliency and temporal saliency are combined to compute the spatiotemporal saliency using an adaptive fusion strategy. Besides, to highlight the spatiotemporal salient regions uniformly, a multi-scale fusion approach is embedded into the spatiotemporal saliency model. Finally, a Gestalt theory-inspired optimization algorithm is designed to further improve the reliability of the final saliency map. Experimental results demonstrate that our method outperforms many state-of-the-art saliency detection approaches for infrared videos under various backgrounds.

  13. A method for detecting fungal contaminants in wall cavities.

    Science.gov (United States)

    Spurgeon, Joe C

    2003-01-01

    This article describes a practical method for detecting the presence of both fungal spores and culturable fungi in wall cavities. Culturable fungi were collected in 25 mm cassettes containing 0.8 microm mixed cellulose ester filters using aggressive sampling conditions. Both culturable fungi and fungal spores were collected in modified slotted-disk cassettes. The sample volume was 4 L. The filters were examined microscopically and dilution plated onto multiple culture media. Collecting airborne samples in filter cassettes was an effective method for assessing wall cavities for fungal contaminants, especially because this method allowed the sample to be analyzed by both microscopy and culture media. Assessment criteria were developed that allowed the sample results to be used to classify wall cavities as either uncontaminated or contaminated. As a criterion, wall cavities with concentrations of culturable fungi below the limit of detection (LOD) were classified as uncontaminated, whereas those cavities with detectable concentrations of culturable fungi were classified as contaminated. A total of 150 wall cavities was sampled as part of a field project. The concentrations of culturable fungi were below the LOD in 34% of the samples, whereas Aspergillus and/or Penicillium were the only fungal genera detected in 69% of the samples in which culturable fungi were detected. Spore counting resulted in the detection of Stachybotrys-like spores in 25% of the samples that were analyzed, whereas Stachybotrys chartarum colonies were only detected on 2% of malt extract agar plates and on 6% of corn meal agar plates.

  14. Determination of detection limits for a VPD ICPMS method of analysis; Determination des limites de detection d'une methode d'analyse VPD ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Badard, M.; Veillerot, M

    2007-07-01

    This training course report presents the different methods of detection and quantifying of metallic impurities in semiconductors. One of the most precise technique is the collection of metal impurities by vapor phase decomposition (VPD) followed by their analysis by ICPMS (inductively coupled plasma mass spectrometry). The study shows the importance of detection limits in the domain of chemical analysis and the way to determine them for the ICPMS analysis. The results found on detection limits are excellent. Even if the detection limits reached with ICPMS performed after manual or automatic VPD are much higher than detection limits of ICPMS alone, this method remains one of the most sensible for ultra-traces analysis. (J.S.)

  15. Hemoglobin and hematocrit values of Saudi newborns in the high altitude of Abha, Saudi Arabia

    International Nuclear Information System (INIS)

    Bassuni, W.; Asindi, A.A.; Mustafa, F.S.; Hassan, B.; Din, Z.S.; Kumar, R.K.

    1996-01-01

    A study was designed to determine the red cell values (hemoglobin and hematocrit) of neonates born in the high altitude of Abha and to compare these values with known values of other lowland areas of Saudi Arabia. From the cord blood of 587 normal, appropriate for gestational age and term infants born in 1993 in Abha Maternity Hospital, the ranges of Hb and Hct were 130 to 240 g/L and 0.24 to 0.79 L/L respectively. The mean Hb was 187 g/L. There was no significant difference between the male and female values. Also, 17% of the infants in this study were polycythemic, while no polycythemia was recorded in these lowland areas and only 2% to 4% in the general global newborn population. It was therefore revealed that Abha newborns had higher red cell values at the birth when compared to other newborns in the low altitude areas of Riyadh and Jeddah (P<0.001). We postulate that high altitude (2700 meters above sea level) of Abha, and therefore its relative hypoxia, has induced high red cell values in infants born in the city. The phenomenon therefore warrants the adoption of higher red cell reference values and not necessarily those already documented in other Saudi new born populations. (author)

  16. The Use of Highly Sensitive Detection Methods for Eradication of Plasmodium

    DEFF Research Database (Denmark)

    Hede, Marianne Smedegaard; Knudsen, Birgitta R.

    2017-01-01

    The key to a successful malaria eradication program is highly efficient detection of Plasmodium infected people followed by appropriate treatment to avoid spreading of the parasite. We will discuss some of the demands that such a detection method needs to fulfill and review some of the advantages...... and disadvantages of currently available detection methods...

  17. The availability of the detection method of internal valve leakage using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Suzuki, Akio

    1989-01-01

    The purpose of this study is to estimate the availability of acoustic method to the internal leakage of the valves at power plants. The acoustic method was applied to the valves at the site, and the background noise was measured for the abnormal plantcondition. From the comparison of the background noise date with the experimental results as to relation between leakage flow and acoust signal, the minimum leakage flow rates that can be detected by the acoust signal was suggested. When the background levels are higher than the acoust signal, the method described below was considered that the analysis the remainder among the background noise frequency spectrum and the acoustic signal spectrum become a very useful leak detection method. A few experimental examples of the spectrum analysis that varied the background noise characteristic were given. (author)

  18. Comparative study on 4 quantitative detection methods of apoptosis induced by radiation

    International Nuclear Information System (INIS)

    Yang Yepeng; Chen Guanying; Zhou Mei; Shen Qinjian; Shen Lei; Zhu Yingbao

    2004-01-01

    Objective: To reveal the capability of 4 apoptosis-detecting methods to discriminate between apoptosis and necrosis and show their respective advantages and shortcomings through comparison of detected results and analysis of detection mechanism. Methods: Four methods, PI staining-flow cytometric detection (P-F method), TUNEL labeling-flow cytometric detection (T-F method), annexing V-FITC/PI vital staining-flow cytometric detection (A-F method) and Hoechst/PI vital staining-fluorescence microscopic observation (H-O method), were used to determine apoptosis and necrosis in human breast cancer MCF-7 cell line induced by γ-rays. Hydroxycamptothecine and sodium azide were used to induce positive controls of apoptosis and necrosis respectively. Results: All 4 methods showed good time-dependent and dose dependent respondence to apoptosis induced by γ-rays and hydroxycamptothecine. Apoptotic cell ratios and curve slopes obtained from P-F method were minimum and, on the contrary, those from T-F method were maximum among these 4 methods. With A-F method and H-O method, two sets of data, apoptosis and necrosis, could be gained respectively and the data gained from these two methods were close to equal. A-F method and H-O method could distinguish necrosis induced by sodium azide from apoptosis while P-F method and T-F method presented false increase of apoptosis. Conclusions: P-F method and T-F method can not discriminate between apoptosis and necrosis. P-F method is less sensitive but more simple, convenient and economical than T-F method. A-F method and H-O method can distinguish necrosis from apoptosis. A-F method is more costly but more quick and reliable than H-O method. H-O method is economical, practical and morphological changes of cells and nucleus can be observed simultaneously with it. (authors)

  19. Detection of food irradiation - two analytical methods

    International Nuclear Information System (INIS)

    1994-01-01

    This publication summarizes the activities of Nordic countries in the field of detection of irradiated food. The National Food Agency of Denmark has coordinated the project. The two analytical methods investigated were: the gas-chromatographic determination of the hydrocarbon/lipid ratio in irradiated chicken meat, and a bioassay based on microelectrophoresis of DNA from single cells. Also a method for determination of o-tyrosine in the irradiated and non-irradiated chicken meat has been tested. The first method based on radiolytical changes in fatty acids, contained in chicken meat, has been tested and compared in the four Nordic countries. Four major hydrocarbons (C16:2, C16:3, C17:1 and C17:2) have been determined and reasonable agreement was observed between the dose level and hydrocarbons concentration. Results of a bioassay, where strand breaks of DNA are demonstrated by microelectrophoresis of single cells, prove a correlation between the dose levels and the pattern of DNA fragments migration. The hydrocarbon method can be applied to detect other irradiated, fat-containing foods, while the DNA method can be used for some animal and some vegetable foods as well.Both methods allow to determine the fact of food irradiation beyond any doubt, thus making them suitable for food control analysis. The detailed determination protocols are given. (EG)

  20. The Effectiveness of Fraud Prevention and Detection Methods at Universities in Indonesia

    OpenAIRE

    Zamzami, Faiz; Nusa, Nabella Duta; Timur, Rudi Prasetya

    2016-01-01

    Some cases of corruption have taken place in several universities in Indonesia. To prevent and handle the cases, internal auditors play pivotal roles in detecting and preventing fraud. Therefore, effective methods to detect and prevent fraud are needed. The methods are expected to set the appropriate measures to detect and prevent fraud effectively. This research proposed a question how the internal auditors perceive the effectiveness of fraud detection and prevention methods. The research ai...

  1. Radiation detection and measurement concepts, methods and devices

    CERN Document Server

    McGregor, Douglas

    2019-01-01

    This text on radiation detection and measurement is a response to numerous requests expressed by students at various universities, in which the most popularly used books do not provide adequate background material, nor explain matters in understandable terms. This work provides a modern overview of radiation detection devices and radiation measurement methods. The topics selected in the book have been selected on the basis of the author’s many years of experience designing radiation detectors and teaching radiation detection and measurement in a classroom environment.

  2. Machine Learning Methods for Attack Detection in the Smart Grid.

    Science.gov (United States)

    Ozay, Mete; Esnaola, Inaki; Yarman Vural, Fatos Tunay; Kulkarni, Sanjeev R; Poor, H Vincent

    2016-08-01

    Attack detection problems in the smart grid are posed as statistical learning problems for different attack scenarios in which the measurements are observed in batch or online settings. In this approach, machine learning algorithms are used to classify measurements as being either secure or attacked. An attack detection framework is provided to exploit any available prior knowledge about the system and surmount constraints arising from the sparse structure of the problem in the proposed approach. Well-known batch and online learning algorithms (supervised and semisupervised) are employed with decision- and feature-level fusion to model the attack detection problem. The relationships between statistical and geometric properties of attack vectors employed in the attack scenarios and learning algorithms are analyzed to detect unobservable attacks using statistical learning methods. The proposed algorithms are examined on various IEEE test systems. Experimental analyses show that machine learning algorithms can detect attacks with performances higher than attack detection algorithms that employ state vector estimation methods in the proposed attack detection framework.

  3. COMPARISON OF FOUR METHODS TO DETECT ADVERSE EVENTS IN HOSPITAL

    Directory of Open Access Journals (Sweden)

    Inge Dhamanti

    2015-09-01

    Full Text Available AbstrakDeteksi terjadinya kejadian yang tidak diharapkan (KTD telah menjadi salah satu tantangan dalam keselamatan pasien oleh karena itu metode untuk mendeteksi terjadinya KTD sangatlah penting untuk meningkatkan keselamatan pasien. Tujuan dari artikel ini adalah untuk membandingkan kelebihan dan kekurangan dari beberapa metode untuk mendeteksi terjadinya KTD di rumah sakit, meliputi review rekam medis, pelaporan insiden secara mandiri, teknologi informasi, dan pelaporan oleh pasien. Studi ini merupakan kajian literatur untuk membandingkan dan menganalisa metode terbaik untuk mendeteksi KTD yang dapat diimplementasikan oleh rumah sakit. Semua dari empat metode telah terbukti mampu untuk mendeteksi terjadinya KTD di rumah sakit, tetapi masing-masing metode mempunyai kelebihan dan kekurangan yang perlu diatasi. Tidak ada satu metode terbaik yang akan memberikan hasil terbaik untuk mendeteksi KTD di rumah sakit. Sehingga untuk mendeteksi lebih banyak KTD yang seharusnya dapat dicegah, atau KTD yang telah terjadi, rumah sakit seharusnya mengkombinasikan lebih dari satu metode untuk mendeteksi, karena masing-masing metode mempunyai sensitivitas berbeda-beda.AbstractDetecting adverse events has become one of the challenges in patient safety thus methods to detect adverse events become critical for improving patient safety. The purpose of this paper is to compare the strengths and weaknesses of several methods of identifying adverse events in hospital, including medical records reviews, self-reported incidents, information technology, and patient self-reports. This study is a literature review to compared and analyzed to determine the best method implemented by the hospital. All of four methods have been proved in their ability in detecting adverse events in hospitals, but each method had strengths and limitations to be overcome. There is no ‘best’ single method that will give the best results for adverse events detection in hospital. Thus to

  4. Detection of food irradiation with luminescence methods

    International Nuclear Information System (INIS)

    Anderle, H.

    1997-06-01

    Food irradiation is applied as method for the preservation of foods, the prevention of food spoilage and the inhibition of food-borne pathogens. Doses exceeding 10 kGy (10 kJ/kg) are not recommended by the WHO. The different legislation requires methods for the detection and the closimetry of irradiated foods. Among the physical methods based on the radiation-induced changes in inorganic, nonhygroscopic crystalline solids are thermoluminescence (TL), photostimulated luminescence (PSL) and lyoluminescence (LL) measurement. The luminescence methods were tested on natural minerals. Pure quartz, feldspars, calcite, aragonite and dolomite of known origin were irradiated, read out and analyzed to determine the influence of luminescence-activators and deactivators. Carbonate minerals show an orange-red TL easily detectable by blue-sensitive photomultiplier tubes. TIL-inactive carbonate samples may be identified by a lyoluminescence method using the reaction of trapped irradiation-generated charge carriers with the solvent during crystal-lattice breakup. The fine-ground mineral is dissolved in an alkaline complexing agent/chemiluminescence sensitizer/chemiluminescence catalyst (EDTA/luminol/hemin) reagent mixture. The TL and PSL of quartz is too weak to contribute a significant part for the corresponding signals in polymineral dust. Alkali and soda feldspar show intense TL and PSL. The temperature maxima in the TL glow curves allow a clear distinction. PSL does not give this additional information, it suffers from bleaching by ambient light and requires light-protection. Grain disinfestated with low irradiation doses (500 Gy) may not identified by both TL and PSL measurement. The natural TL of feldspar particles may be overlap with the irradiation-induced TL of other minerals. As a routine method, irradiated spices are identified with TL measurement. The dust particles have to be enriched by heavy-liquid flotation and centrifugation. The PSL method allows a clear

  5. Methods for detection of GMOs in food and feed.

    Science.gov (United States)

    Marmiroli, Nelson; Maestri, Elena; Gullì, Mariolina; Malcevschi, Alessio; Peano, Clelia; Bordoni, Roberta; De Bellis, Gianluca

    2008-10-01

    This paper reviews aspects relevant to detection and quantification of genetically modified (GM) material within the feed/food chain. The GM crop regulatory framework at the international level is evaluated with reference to traceability and labelling. Current analytical methods for the detection, identification, and quantification of transgenic DNA in food and feed are reviewed. These methods include quantitative real-time PCR, multiplex PCR, and multiplex real-time PCR. Particular attention is paid to methods able to identify multiple GM events in a single reaction and to the development of microdevices and microsensors, though they have not been fully validated for application.

  6. Application of measuring 99mTc-MAG3 plasma clearance based on one-compartment model (MPC method) to pediatric patients

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Higashida, Kousuke; Arbab, A.S.; Toyama, Keiji; Arai, Takao; Yoshitomi, Tatsuya.

    1997-01-01

    Measurement of 99m Tc-MAG3 plasma clearance based on 1-compartment model (MPC method) were applied to 12 pediatric patients and evaluated for the factors which might affect the calculated results. Depth correction is a critical factor for the measurement of renal uptake. Three different equations for estimating renal depth were compared with the real depth measured by ultrasonography. The equation proposed by K. Itoh was suitable though the equations by T. Ito and Raynaud were insufficient. Estimation of distribution volume, which is regarded as circulating plasma volume (CPV), is also critical for the calculation of MAG3 clearance by MPC method. Precisely, hematocrit measured by venous sampling and circulating blood volume (CBV) calculated as 7.5% of body weight are used for estimation of CPV. However, assumed CPV as 5% of body weight was acceptable if the hematocrit was not severely deviated from the normal value. Simplified MPC method utilizing two factors mentioned above gave a positive correlation with Russell's one point sampling method. In conclusion, MPC method is applicable for pediatric patients. (author)

  7. Cost-Effectiveness Analysis of Three Leprosy Case Detection Methods in Northern Nigeria

    Science.gov (United States)

    Ezenduka, Charles; Post, Erik; John, Steven; Suraj, Abdulkarim; Namadi, Abdulahi; Onwujekwe, Obinna

    2012-01-01

    Background Despite several leprosy control measures in Nigeria, child proportion and disability grade 2 cases remain high while new cases have not significantly reduced, suggesting continuous spread of the disease. Hence, there is the need to review detection methods to enhance identification of early cases for effective control and prevention of permanent disability. This study evaluated the cost-effectiveness of three leprosy case detection methods in Northern Nigeria to identify the most cost-effective approach for detection of leprosy. Methods A cross-sectional study was carried out to evaluate the additional benefits of using several case detection methods in addition to routine practice in two north-eastern states of Nigeria. Primary and secondary data were collected from routine practice records and the Nigerian Tuberculosis and Leprosy Control Programme of 2009. The methods evaluated were Rapid Village Survey (RVS), Household Contact Examination (HCE) and Traditional Healers incentive method (TH). Effectiveness was measured as number of new leprosy cases detected and cost-effectiveness was expressed as cost per case detected. Costs were measured from both providers' and patients' perspectives. Additional costs and effects of each method were estimated by comparing each method against routine practise and expressed as incremental cost-effectiveness ratio (ICER). All costs were converted to the U.S. dollar at the 2010 exchange rate. Univariate sensitivity analysis was used to evaluate uncertainties around the ICER. Results The ICER for HCE was $142 per additional case detected at all contact levels and it was the most cost-effective method. At ICER of $194 per additional case detected, THs method detected more cases at a lower cost than the RVS, which was not cost-effective at $313 per additional case detected. Sensitivity analysis showed that varying the proportion of shared costs and subsistent wage for valuing unpaid time did not significantly change the

  8. Thin Cloud Detection Method by Linear Combination Model of Cloud Image

    Science.gov (United States)

    Liu, L.; Li, J.; Wang, Y.; Xiao, Y.; Zhang, W.; Zhang, S.

    2018-04-01

    The existing cloud detection methods in photogrammetry often extract the image features from remote sensing images directly, and then use them to classify images into cloud or other things. But when the cloud is thin and small, these methods will be inaccurate. In this paper, a linear combination model of cloud images is proposed, by using this model, the underlying surface information of remote sensing images can be removed. So the cloud detection result can become more accurate. Firstly, the automatic cloud detection program in this paper uses the linear combination model to split the cloud information and surface information in the transparent cloud images, then uses different image features to recognize the cloud parts. In consideration of the computational efficiency, AdaBoost Classifier was introduced to combine the different features to establish a cloud classifier. AdaBoost Classifier can select the most effective features from many normal features, so the calculation time is largely reduced. Finally, we selected a cloud detection method based on tree structure and a multiple feature detection method using SVM classifier to compare with the proposed method, the experimental data shows that the proposed cloud detection program in this paper has high accuracy and fast calculation speed.

  9. Improvement to defect detection by ultrasonic data processing: the DTVG method

    International Nuclear Information System (INIS)

    Francois, D.

    1995-10-01

    The cast elbows of the pipes of the principal primary circuit of French PWR, made of austenitic-ferritic stainless steel, pose problems to control. In order to improve the ultrasonic detection of defects in coarse-grained materials, we propose a method (called DTVG) based on the statistic study of the spatial stability of events contained in temporal signals. At the Beginning, the method was developed during a thesis (G. Corneloup, 1998) to improve the detection of cracks in thin thickness austenitic welds. Here, we propose to adapt the DTVG method and estimate its performances in detection of defects in thick materials representative of cast austenitic-ferritic elbows steels. The first objective of the study is adapting the original treatment applied to the thin thickness austenitic welds for the detection of defects in thick thickness austenitic-ferritic cast steels. The second objective consist of improving the algorithm to take in account the difference between thin and thick material and estimating the performances of the DTVG method in detection in specimen block with artificial defects. This work has led to adapt the original DTVG method to control thick cast austenitic-ferritic specimen (80 mm) under normal and oblique incidence. More, the study has allowed to make the the treatment automatic (automatic research of parameters). The results have shown that the DTVG method is fitted to detect artificial defects in thick cast austenitic-ferritic sample steel. All the defects in the specimen block have been detected without revealing false indication. (author). 4 refs., 4 figs

  10. Recent developments in analytical detection methods for radiation processed foods

    International Nuclear Information System (INIS)

    Wu Jilan

    1993-01-01

    A short summary of the programmes of 'ADMIT' (FAO/IAEA) and the developments in analytical detection methods for radiation processed foods has been given. It is suggested that for promoting the commercialization of radiation processed foods and controlling its quality, one must pay more attention to the study of analytical detection methods of irradiated food

  11. Rapid method for Detection of Irradiation Mango Fruits

    International Nuclear Information System (INIS)

    El Salhy, F.T.

    2011-01-01

    To detect mango fruits which have been exposed to low doses of gamma rays (0.5-3.0 kGy), three recommended methods by European Committee for Standardization (EN 1784:1996, EN 1785:1996 and EN 1787:2000) were used to study the possibility for identification of irradiated mango fruits (Ewais variety). Fresh mangoes were irradiated to different doses (0.5, 0.75, 1.0 and 3.0 kGy). The first method for determining the volatile hydrocarbons (VHC) was carried out by using florisil column then identified by gas chromatography and mass spectrometry (GC-MS). The major VHCs were C14:1, C15:0 and C17:1 at different doses which increased linearly with increasing doses either at low or high doses. The second one for determining the 2-alkyl cyclobutanone (2-DCB) was carried out using florisil chromatography method activated with 20% for separation and identified by GC-MS. 2-DCB bio marker specific for irradiated food proved its presence at the applied doses from 0.75-3.0 kGy but not at 0.5 kGy. All the mentioned compounds could not detected in non-irradiated samples, which mean that these radiolytic products (VHC and 2-DCB) can be used as a detection markers for irradiated mangoes even at low doses. The third one (EN 1787:2000) was conducted by electron spin resonance (ESR) on dried petioles of mangoes. The results proved that ESR was more sensitive for all applied doses.It could be concluded that using the three methods can be succeeded for detection of irradiated mangoes but the rapid one even at low doses with high accuracy was ESR.

  12. Method for detecting resin leakage in LWR coolant

    International Nuclear Information System (INIS)

    Girard, J.E.

    1988-05-01

    Resin leakage from condensate polishing units can result in steam generator corrosion. This report describes the development of a resin leakage detection method based in analyzing the organic breakdown products released from resin on heating. The breakdown products are analyzed using high performance liquid chromatography (HPLC) with fluorescence detection. Some of the organic products formed have been identified. A design for a resin monitoring unit, suitable for incorporation into the IONTRAC system, is presented. Theoretically, detection of ppB levels of resin by processing about one liter of water, is possible

  13. A new ultrasonic signal amplification method for detection of bacteria

    Science.gov (United States)

    Kant Shukla, Shiva; Resa López, Pablo; Sierra Sánchez, Carlos; Urréjola, José; Segura, Luis Elvira

    2012-10-01

    A new method is presented that increases the sensitivity of ultrasound-based techniques for detection of bacteria. The technique was developed for the detection of catalase-positive microorganisms. It uses a bubble trapping medium containing hydrogen peroxide that is mixed with the sample for microbiological evaluation. The enzyme catalase is present in catalase-positive bacteria, which induces a rapid hydrolysis of hydrogen peroxide, forming bubbles which remain in the medium. This reaction results in the amplification of the mechanical changes that the microorganisms produce in the medium. The effect can be detected by means of ultrasonic wave amplitude continuous measurement since the bubbles increase the ultrasonic attenuation significantly. It is shown that microorganism concentrations of the order of 105 cells ml-1 can be detected using this method. This allows an improvement of three orders of magnitude in the ultrasonic detection threshold of microorganisms in conventional culture media, and is competitive with modern rapid microbiological methods. It can also be used for the characterization of the enzymatic activity.

  14. A new ultrasonic signal amplification method for detection of bacteria

    International Nuclear Information System (INIS)

    Shukla, Shiva Kant; López, Pablo Resa; Sánchez, Carlos Sierra; Segura, Luis Elvira; Urréjola, José

    2012-01-01

    A new method is presented that increases the sensitivity of ultrasound-based techniques for detection of bacteria. The technique was developed for the detection of catalase-positive microorganisms. It uses a bubble trapping medium containing hydrogen peroxide that is mixed with the sample for microbiological evaluation. The enzyme catalase is present in catalase-positive bacteria, which induces a rapid hydrolysis of hydrogen peroxide, forming bubbles which remain in the medium. This reaction results in the amplification of the mechanical changes that the microorganisms produce in the medium. The effect can be detected by means of ultrasonic wave amplitude continuous measurement since the bubbles increase the ultrasonic attenuation significantly. It is shown that microorganism concentrations of the order of 10 5 cells ml −1 can be detected using this method. This allows an improvement of three orders of magnitude in the ultrasonic detection threshold of microorganisms in conventional culture media, and is competitive with modern rapid microbiological methods. It can also be used for the characterization of the enzymatic activity. (paper)

  15. An Automata Based Intrusion Detection Method for Internet of Things

    Directory of Open Access Journals (Sweden)

    Yulong Fu

    2017-01-01

    Full Text Available Internet of Things (IoT transforms network communication to Machine-to-Machine (M2M basis and provides open access and new services to citizens and companies. It extends the border of Internet and will be developed as one part of the future 5G networks. However, as the resources of IoT’s front devices are constrained, many security mechanisms are hard to be implemented to protect the IoT networks. Intrusion detection system (IDS is an efficient technique that can be used to detect the attackers when cryptography is broken, and it can be used to enforce the security of IoT networks. In this article, we analyzed the intrusion detection requirements of IoT networks and then proposed a uniform intrusion detection method for the vast heterogeneous IoT networks based on an automata model. The proposed method can detect and report the possible IoT attacks with three types: jam-attack, false-attack, and reply-attack automatically. We also design an experiment to verify the proposed IDS method and examine the attack of RADIUS application.

  16. Analytical detection methods for irradiated foods

    International Nuclear Information System (INIS)

    1991-03-01

    The present publication is a review of scientific literature on the analytical identification of foods treated with ionizing radiation and the quantitative determination of absorbed dose of radiation. Because of the extremely low level of chemical changes resulting from irradiation or because of the lack of specificity to irradiation of any chemical changes, a few methods of quantitative determination of absorbed dose have shown promise until now. On the other hand, the present review has identified several possible methods, which could be used, following further research and testing, for the identification of irradiated foods. An IAEA Co-ordinated Research Programme on Analytical Detection Methods for Irradiation Treatment of Food ('ADMIT'), established in 1990, is currently investigating many of the methods cited in the present document. Refs and tab

  17. Median Filtering Methods for Non-volcanic Tremor Detection

    Science.gov (United States)

    Damiao, L. G.; Nadeau, R. M.; Dreger, D. S.; Luna, B.; Zhang, H.

    2016-12-01

    Various properties of median filtering over time and space are used to address challenges posed by the Non-volcanic tremor detection problem. As part of a "Big-Data" effort to characterize the spatial and temporal distribution of ambient tremor throughout the Northern San Andreas Fault system, continuous seismic data from multiple seismic networks with contrasting operational characteristics and distributed over a variety of regions are being used. Automated median filtering methods that are flexible enough to work consistently with these data are required. Tremor is characterized by a low-amplitude, long-duration signal-train whose shape is coherent at multiple stations distributed over a large area. There are no consistent phase arrivals or mechanisms in a given tremor's signal and even the durations and shapes among different tremors vary considerably. A myriad of masquerading noise, anthropogenic and natural-event signals must also be discriminated in order to obtain accurate tremor detections. We present here results of the median methods applied to data from four regions of the San Andreas Fault system in northern California (Geysers Geothermal Field, Napa, Bitterwater and Parkfield) to illustrate the ability of the methods to detect tremor under diverse conditions.

  18. High sensitive quench detection method using an integrated test wire

    International Nuclear Information System (INIS)

    Fevrier, A.; Tavergnier, J.P.; Nithart, H.; Kiblaire, M.; Duchateau, J.L.

    1981-01-01

    A high sensitive quench detection method which works even in the presence of an external perturbing magnetic field is reported. The quench signal is obtained from the difference in voltages at the superconducting winding terminals and at the terminals at a secondary winding strongly coupled to the primary. The secondary winding could consist of a ''zero-current strand'' of the superconducting cable not connected to one of the winding terminals or an integrated normal test wire inside the superconducting cable. Experimental results on quench detection obtained by this method are described. It is shown that the integrated test wire method leads to efficient and sensitive quench detection, especially in the presence of an external perturbing magnetic field

  19. Position detectors, methods of detecting position, and methods of providing positional detectors

    Science.gov (United States)

    Weinberg, David M.; Harding, L. Dean; Larsen, Eric D.

    2002-01-01

    Position detectors, welding system position detectors, methods of detecting various positions, and methods of providing position detectors are described. In one embodiment, a welding system positional detector includes a base that is configured to engage and be moved along a curved surface of a welding work piece. At least one position detection apparatus is provided and is connected with the base and configured to measure angular position of the detector relative to a reference vector. In another embodiment, a welding system positional detector includes a weld head and at least one inclinometer mounted on the weld head. The one inclinometer is configured to develop positional data relative to a reference vector and the position of the weld head on a non-planar weldable work piece.

  20. Spectral anomaly methods for aerial detection using KUT nuisance rejection

    International Nuclear Information System (INIS)

    Detwiler, R.S.; Pfund, D.M.; Myjak, M.J.; Kulisek, J.A.; Seifert, C.E.

    2015-01-01

    This work discusses the application and optimization of a spectral anomaly method for the real-time detection of gamma radiation sources from an aerial helicopter platform. Aerial detection presents several key challenges over ground-based detection. For one, larger and more rapid background fluctuations are typical due to higher speeds, larger field of view, and geographically induced background changes. As well, the possible large altitude or stand-off distance variations cause significant steps in background count rate as well as spectral changes due to increased gamma-ray scatter with detection at higher altitudes. The work here details the adaptation and optimization of the PNNL-developed algorithm Nuisance-Rejecting Spectral Comparison Ratios for Anomaly Detection (NSCRAD), a spectral anomaly method previously developed for ground-based applications, for an aerial platform. The algorithm has been optimized for two multi-detector systems; a NaI(Tl)-detector-based system and a CsI detector array. The optimization here details the adaptation of the spectral windows for a particular set of target sources to aerial detection and the tailoring for the specific detectors. As well, the methodology and results for background rejection methods optimized for the aerial gamma-ray detection using Potassium, Uranium and Thorium (KUT) nuisance rejection are shown. Results indicate that use of a realistic KUT nuisance rejection may eliminate metric rises due to background magnitude and spectral steps encountered in aerial detection due to altitude changes and geographically induced steps such as at land–water interfaces

  1. Alcohol Detection in Exhaled Air by NDIR Method

    Science.gov (United States)

    Fujitsuka, Norio; Yonemura, Masatoshi; Sakakibara, Kiyomi; Taguchi, Toshiyuki; Wakita, Toshihiro

    In recent years, the increase in traffic accidents associated with drunk driving has become a serious social issue. Therefore, there is a need for an in-vehicle system that can detect the fact that the driver is under the influence of alcohol. We thought a method for alcohol detection in the breath of the driver, based on a nondispersive infrared (NDIR) method, is suitable for this system. Since alcohol content in the driver's breath is significantly diluted at the sensor device, it is necessary that the sensor is highly sensitive to detect diluted alcohol. A quantum cascade laser was used to produce highly intense infrared light source. An infrared hollow fiber used in medical treatment was utilized as a gas absorption cell. Since the core of the fiber is hollow, gas is introduced for analyzer. The flexibility of the fiber allowed it to be looped so that 2 m fiber in length could be formed into a compact coil of 29 cm in diameter. It was clarified that the light intensity change of light output from the hollow fiber with ethanol density, and rarefied ethanol as small as 1 ppm in density was detected.

  2. Hand-Eye LRF-Based Iterative Plane Detection Method for Autonomous Robotic Welding

    Directory of Open Access Journals (Sweden)

    Sungmin Lee

    2015-12-01

    Full Text Available This paper proposes a hand-eye LRF-based (laser range finder welding plane-detection method for autonomous robotic welding in the field of shipbuilding. The hand-eye LRF system consists of a 6 DOF manipulator and an LRF attached to the wrist of the manipulator. The welding plane is detected by the LRF with only the wrist's rotation to minimize a mechanical error caused by the manipulator's motion. A position on the plane is determined as an average position of the detected points on the plane, and a normal vector to the plane is determined by applying PCA (principal component analysis to the detected points. In this case, the accuracy of the detected plane is analysed by simulations with respect to the wrist's angle interval and the plane angle. As a result of the analysis, an iterative plane-detection method with the manipulator's alignment motion is proposed to improve the performance of plane detection. For verifying the feasibility and effectiveness of the proposed plane-detection method, experiments are carried out with a prototype of the hand-eye LRF-based system, which consists of a 1 DOF wrist's joint, an LRF system and a rotatable plane. In addition, the experimental results of the PCA-based plane detection method are compared with those of the two representative plane-detection methods, based on RANSAC (RANdom SAmple Consensus and the 3D Hough transform in both accuracy and computation time's points of view.

  3. Cellular Neural Network-Based Methods for Distributed Network Intrusion Detection

    Directory of Open Access Journals (Sweden)

    Kang Xie

    2015-01-01

    Full Text Available According to the problems of current distributed architecture intrusion detection systems (DIDS, a new online distributed intrusion detection model based on cellular neural network (CNN was proposed, in which discrete-time CNN (DTCNN was used as weak classifier in each local node and state-controlled CNN (SCCNN was used as global detection method, respectively. We further proposed a new method for design template parameters of SCCNN via solving Linear Matrix Inequality. Experimental results based on KDD CUP 99 dataset show its feasibility and effectiveness. Emerging evidence has indicated that this new approach is affordable to parallelism and analog very large scale integration (VLSI implementation which allows the distributed intrusion detection to be performed better.

  4. Roka Listeria detection method using transcription mediated amplification to detect Listeria species in select foods and surfaces. Performance Tested Method(SM) 011201.

    Science.gov (United States)

    Hua, Yang; Kaplan, Shannon; Reshatoff, Michael; Hu, Ernie; Zukowski, Alexis; Schweis, Franz; Gin, Cristal; Maroni, Brett; Becker, Michael; Wisniewski, Michele

    2012-01-01

    The Roka Listeria Detection Assay was compared to the reference culture methods for nine select foods and three select surfaces. The Roka method used Half-Fraser Broth for enrichment at 35 +/- 2 degrees C for 24-28 h. Comparison of Roka's method to reference methods requires an unpaired approach. Each method had a total of 545 samples inoculated with a Listeria strain. Each food and surface was inoculated with a different strain of Listeria at two different levels per method. For the dairy products (Brie cheese, whole milk, and ice cream), our method was compared to AOAC Official Method(SM) 993.12. For the ready-to-eat meats (deli chicken, cured ham, chicken salad, and hot dogs) and environmental surfaces (sealed concrete, stainless steel, and plastic), these samples were compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) method MLG 8.07. Cold-smoked salmon and romaine lettuce were compared to the U.S. Food and Drug Administration/Bacteriological Analytical Manual, Chapter 10 (FDA/BAM) method. Roka's method had 358 positives out of 545 total inoculated samples compared to 332 positive for the reference methods. Overall the probability of detection analysis of the results showed better or equivalent performance compared to the reference methods.

  5. Metagenomic Detection Methods in Biopreparedness Outbreak Scenarios

    DEFF Research Database (Denmark)

    Karlsson, Oskar Erik; Hansen, Trine; Knutsson, Rickard

    2013-01-01

    In the field of diagnostic microbiology, rapid molecular methods are critically important for detecting pathogens. With rapid and accurate detection, preventive measures can be put in place early, thereby preventing loss of life and further spread of a disease. From a preparedness perspective...... of a clinical sample, creating a metagenome, in a single week of laboratory work. As new technologies emerge, their dissemination and capacity building must be facilitated, and criteria for use, as well as guidelines on how to report results, must be established. This article focuses on the use of metagenomics...

  6. Incidentally detected gastrointestinal stromal tumor: A case report

    Directory of Open Access Journals (Sweden)

    Tolga Canbak

    2017-12-01

    Full Text Available Gastrointestinal stromal tumors (GIST are mesenchymal tumors located primarily in the gastrointestinal tract. We aimed to present a case report of GIST incidentally detected during laparoscopic cholecystectomy.A 60-year-old woman was admitted to the emergency room due to abdominal pain for one day. The physical examination revealed sensitivity on the right upper quadrant. In the laboratory examinations, white blood cell count 6,490 k/uL, hemoglobin 12 g/dL, hematocrit 35% and other biochemical tests were normal. Abdominal ultrasound revealed hydropic gallbladder, several gallstones with a maximum diameter of 15 mm and pericholecystic fluid collection was present. Laparoscopic cholecystectomy was planned due to acute cholecystitis. In exploration, beside the presence of acute cholecystitis, a mass of approximately 5 cm, located 15 cm distal to the ligament of Treitz was detected. Laparoscopic cholecystectomy was performed. Conversion to open laparotomy was done; small intestine resection with end-to-end anastomosis was performed. Gastrointestinal stromal tumor with CD117, CD34 and S100 positivity was detected on histopathologic examination.It is thought that GISTs are mesenchymal tumors originating from precursors of Kajal cells. GISTs are usually detected in their 60s. The first option for treatment is surgical resection.

  7. A surface acoustic wave response detection method for passive wireless torque sensor

    Science.gov (United States)

    Fan, Yanping; Kong, Ping; Qi, Hongli; Liu, Hongye; Ji, Xiaojun

    2018-01-01

    This paper presents an effective surface acoustic wave (SAW) response detection method for the passive wireless SAW torque sensor to improve the measurement accuracy. An analysis was conducted on the relationship between the response energy-entropy and the bandwidth of SAW resonator (SAWR). A self-correlation method was modified to suppress the blurred white noise and highlight the attenuation characteristic of wireless SAW response. The SAW response was detected according to both the variation and the duration of energy-entropy ascension of an acquired RF signal. Numerical simulation results showed that the SAW response can be detected even when the signal-to-noise ratio (SNR) is 6dB. The proposed SAW response detection method was evaluated with several experiments at different conditions. The SAW response can be well distinguished from the sinusoidal signal and the noise. The performance of the SAW torque measurement system incorporating the detection method was tested. The obtained repeatability error was 0.23% and the linearity was 0.9934, indicating the validity of the detection method.

  8. Waterborne Pathogens: Detection Methods and Challenges

    Directory of Open Access Journals (Sweden)

    Flor Yazmín Ramírez-Castillo

    2015-05-01

    Full Text Available Waterborne pathogens and related diseases are a major public health concern worldwide, not only by the morbidity and mortality that they cause, but by the high cost that represents their prevention and treatment. These diseases are directly related to environmental deterioration and pollution. Despite the continued efforts to maintain water safety, waterborne outbreaks are still reported globally. Proper assessment of pathogens on water and water quality monitoring are key factors for decision-making regarding water distribution systems’ infrastructure, the choice of best water treatment and prevention waterborne outbreaks. Powerful, sensitive and reproducible diagnostic tools are developed to monitor pathogen contamination in water and be able to detect not only cultivable pathogens but also to detect the occurrence of viable but non-culturable microorganisms as well as the presence of pathogens on biofilms. Quantitative microbial risk assessment (QMRA is a helpful tool to evaluate the scenarios for pathogen contamination that involve surveillance, detection methods, analysis and decision-making. This review aims to present a research outlook on waterborne outbreaks that have occurred in recent years. This review also focuses in the main molecular techniques for detection of waterborne pathogens and the use of QMRA approach to protect public health.

  9. Edge detection methods based on generalized type-2 fuzzy logic

    CERN Document Server

    Gonzalez, Claudia I; Castro, Juan R; Castillo, Oscar

    2017-01-01

    In this book four new methods are proposed. In the first method the generalized type-2 fuzzy logic is combined with the morphological gra-dient technique. The second method combines the general type-2 fuzzy systems (GT2 FSs) and the Sobel operator; in the third approach the me-thodology based on Sobel operator and GT2 FSs is improved to be applied on color images. In the fourth approach, we proposed a novel edge detec-tion method where, a digital image is converted a generalized type-2 fuzzy image. In this book it is also included a comparative study of type-1, inter-val type-2 and generalized type-2 fuzzy systems as tools to enhance edge detection in digital images when used in conjunction with the morphologi-cal gradient and the Sobel operator. The proposed generalized type-2 fuzzy edge detection methods were tested with benchmark images and synthetic images, in a grayscale and color format. Another contribution in this book is that the generalized type-2 fuzzy edge detector method is applied in the preproc...

  10. Evaluation of two methods for direct detection of Fusarium spp. in water.

    Science.gov (United States)

    Graça, Mariana G; van der Heijden, Inneke M; Perdigão, Lauro; Taira, Cleison; Costa, Silvia F; Levin, Anna S

    2016-04-01

    Fusarium is a waterborne fungus that causes severe infections especially in patients with prolonged neutropenia. Traditionally, the detection of Fusarium in water is done by culturing which is difficult and time consuming. A faster method is necessary to prevent exposure of susceptible patients to contaminated water. The objective of this study was to develop a molecular technique for direct detection of Fusarium in water. A direct DNA extraction method from water was developed and coupled to a genus-specific PCR, to detect 3 species of Fusarium (verticillioides, oxysporum and solani). The detection limits were 10 cells/L and 1 cell/L for the molecular and culture methods, respectively. To our knowledge, this is the first method developed to detect Fusarium directly from water. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Steam leak detection in advance reactors via acoustics method

    International Nuclear Information System (INIS)

    Singh, Raj Kumar; Rao, A. Rama

    2011-01-01

    Highlights: → Steam leak detection system is developed to detect any leak inside the reactor vault. → The technique uses leak noise frequency spectrum for leak detection. → Testing of system and method to locate the leak is also developed and discussed in present paper. - Abstract: Prediction of LOCA (loss of coolant activity) plays very important role in safety of nuclear reactor. Coolant is responsible for heat transfer from fuel bundles. Loss of coolant is an accidental situation which requires immediate shut down of reactor. Fall in system pressure during LOCA is the trip parameter used for initiating automatic reactor shut down. However, in primary heat transport system operating in two phase regimes, detection of small break LOCA is not simple. Due to very slow leak rates, time for the fall of pressure is significantly slow. From reactor safety point of view, it is extremely important to find reliable and effective alternative for detecting slow pressure drop in case of small break LOCA. One such technique is the acoustic signal caused by LOCA in small breaks. In boiling water reactors whose primary heat transport is to be driven by natural circulation, small break LOCA detection is important. For prompt action on post small break LOCA, steam leak detection system is developed to detect any leak inside the reactor vault. The detection technique is reliable and plays a very important role in ensuring safety of the reactor. Methodology developed for steam leak detection is discussed in present paper. The methods to locate the leak is also developed and discussed in present paper which is based on analysis of the signal.

  12. Some methods of failed fuel element detection in water cooled reactors

    International Nuclear Information System (INIS)

    Strindehag, O.M.

    1976-01-01

    The methods are surveyed using fission products released in the coolant for the detection of failed fuel elements in water cooled reactors. The classification of the detection methods is made with respect to fission product detection in the coolant and to gaseous fission product detection. The detection systems are listed used for the AGESTA power reactor and for the experimental loops of the RA research reactor based on the detection of either gaseous fission products or gaseous daughter products. The AGESTA reactor detection systems using electrostatic precipitators consist of five precipitator channels of which three are intended for detection and two for localization. A special detection unit was developed for the failed fuel element detection in the R-2 reactor experimental steam loop. Its description is listed. In the reactor pressurized-water loop a Cherenkov counter was used in the detection of fission products. An ion exchange monitor whose application is described was used in the total measurement of the main coolant flow in the AGESTA reactor. (J.P.)

  13. GMDD: a database of GMO detection methods

    NARCIS (Netherlands)

    Dong, W.; Yang, L.; Shen, K.; Kim, B.; Kleter, G.A.; Marvin, H.J.P.; Guo, R.; Liang, W.; Zhang, D.

    2008-01-01

    Since more than one hundred events of genetically modified organisms (GMOs) have been developed and approved for commercialization in global area, the GMO analysis methods are essential for the enforcement of GMO labelling regulations. Protein and nucleic acid-based detection techniques have been

  14. On the Evaluation of Outlier Detection and One-Class Classification Methods

    DEFF Research Database (Denmark)

    Swersky, Lorne; Marques, Henrique O.; Sander, Jörg

    2016-01-01

    It has been shown that unsupervised outlier detection methods can be adapted to the one-class classification problem. In this paper, we focus on the comparison of oneclass classification algorithms with such adapted unsupervised outlier detection methods, improving on previous comparison studies ...

  15. Why conventional detection methods fail in identifying the existence of contamination events.

    Science.gov (United States)

    Liu, Shuming; Li, Ruonan; Smith, Kate; Che, Han

    2016-04-15

    Early warning systems are widely used to safeguard water security, but their effectiveness has raised many questions. To understand why conventional detection methods fail to identify contamination events, this study evaluates the performance of three contamination detection methods using data from a real contamination accident and two artificial datasets constructed using a widely applied contamination data construction approach. Results show that the Pearson correlation Euclidean distance (PE) based detection method performs better for real contamination incidents, while the Euclidean distance method (MED) and linear prediction filter (LPF) method are more suitable for detecting sudden spike-like variation. This analysis revealed why the conventional MED and LPF methods failed to identify existence of contamination events. The analysis also revealed that the widely used contamination data construction approach is misleading. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Distance Based Method for Outlier Detection of Body Sensor Networks

    Directory of Open Access Journals (Sweden)

    Haibin Zhang

    2016-01-01

    Full Text Available We propose a distance based method for the outlier detection of body sensor networks. Firstly, we use a Kernel Density Estimation (KDE to calculate the probability of the distance to k nearest neighbors for diagnosed data. If the probability is less than a threshold, and the distance of this data to its left and right neighbors is greater than a pre-defined value, the diagnosed data is decided as an outlier. Further, we formalize a sliding window based method to improve the outlier detection performance. Finally, to estimate the KDE by training sensor readings with errors, we introduce a Hidden Markov Model (HMM based method to estimate the most probable ground truth values which have the maximum probability to produce the training data. Simulation results show that the proposed method possesses a good detection accuracy with a low false alarm rate.

  17. An improved EMD method for modal identification and a combined static-dynamic method for damage detection

    Science.gov (United States)

    Yang, Jinping; Li, Peizhen; Yang, Youfa; Xu, Dian

    2018-04-01

    Empirical mode decomposition (EMD) is a highly adaptable signal processing method. However, the EMD approach has certain drawbacks, including distortions from end effects and mode mixing. In the present study, these two problems are addressed using an end extension method based on the support vector regression machine (SVRM) and a modal decomposition method based on the characteristics of the Hilbert transform. The algorithm includes two steps: using the SVRM, the time series data are extended at both endpoints to reduce the end effects, and then, a modified EMD method using the characteristics of the Hilbert transform is performed on the resulting signal to reduce mode mixing. A new combined static-dynamic method for identifying structural damage is presented. This method combines the static and dynamic information in an equilibrium equation that can be solved using the Moore-Penrose generalized matrix inverse. The combination method uses the differences in displacements of the structure with and without damage and variations in the modal force vector. Tests on a four-story, steel-frame structure were conducted to obtain static and dynamic responses of the structure. The modal parameters are identified using data from the dynamic tests and improved EMD method. The new method is shown to be more accurate and effective than the traditional EMD method. Through tests with a shear-type test frame, the higher performance of the proposed static-dynamic damage detection approach, which can detect both single and multiple damage locations and the degree of the damage, is demonstrated. For structures with multiple damage, the combined approach is more effective than either the static or dynamic method. The proposed EMD method and static-dynamic damage detection method offer improved modal identification and damage detection, respectively, in structures.

  18. Railway clearance intrusion detection method with binocular stereo vision

    Science.gov (United States)

    Zhou, Xingfang; Guo, Baoqing; Wei, Wei

    2018-03-01

    In the stage of railway construction and operation, objects intruding railway clearance greatly threaten the safety of railway operation. Real-time intrusion detection is of great importance. For the shortcomings of depth insensitive and shadow interference of single image method, an intrusion detection method with binocular stereo vision is proposed to reconstruct the 3D scene for locating the objects and judging clearance intrusion. The binocular cameras are calibrated with Zhang Zhengyou's method. In order to improve the 3D reconstruction speed, a suspicious region is firstly determined by background difference method of a single camera's image sequences. The image rectification, stereo matching and 3D reconstruction process are only executed when there is a suspicious region. A transformation matrix from Camera Coordinate System(CCS) to Track Coordinate System(TCS) is computed with gauge constant and used to transfer the 3D point clouds into the TCS, then the 3D point clouds are used to calculate the object position and intrusion in TCS. The experiments in railway scene show that the position precision is better than 10mm. It is an effective way for clearance intrusion detection and can satisfy the requirement of railway application.

  19. Rapid detection of Salmonella in pet food: design and evaluation of integrated methods based on real-time PCR detection.

    Science.gov (United States)

    Balachandran, Priya; Friberg, Maria; Vanlandingham, V; Kozak, K; Manolis, Amanda; Brevnov, Maxim; Crowley, Erin; Bird, Patrick; Goins, David; Furtado, Manohar R; Petrauskene, Olga V; Tebbs, Robert S; Charbonneau, Duane

    2012-02-01

    Reducing the risk of Salmonella contamination in pet food is critical for both companion animals and humans, and its importance is reflected by the substantial increase in the demand for pathogen testing. Accurate and rapid detection of foodborne pathogens improves food safety, protects the public health, and benefits food producers by assuring product quality while facilitating product release in a timely manner. Traditional culture-based methods for Salmonella screening are laborious and can take 5 to 7 days to obtain definitive results. In this study, we developed two methods for the detection of low levels of Salmonella in pet food using real-time PCR: (i) detection of Salmonella in 25 g of dried pet food in less than 14 h with an automated magnetic bead-based nucleic acid extraction method and (ii) detection of Salmonella in 375 g of composite dry pet food matrix in less than 24 h with a manual centrifugation-based nucleic acid preparation method. Both methods included a preclarification step using a novel protocol that removes food matrix-associated debris and PCR inhibitors and improves the sensitivity of detection. Validation studies revealed no significant differences between the two real-time PCR methods and the standard U.S. Food and Drug Administration Bacteriological Analytical Manual (chapter 5) culture confirmation method.

  20. Evaluation of primary coolant leaks and assessment of detection methods

    International Nuclear Information System (INIS)

    Cassette, P.; Giroux, C.; Roche, H.; Seveon, J.J.

    1986-01-01

    A review of the French PWR situation concerning primary coolant leaks is presented, including a description of operating technical specifications, of the collecting system of primary coolant leakage into the containment and of the detection methods. It is mainly based on a compilation over three years, 1981 to 1983, of almost all actual leaks, their natures, causes, consequences and methods used for their detection. By analysing these data it is possible to evaluate the efficiency of the primary coolant leak detection system and the problems raised by compliance with the criteria defined in the operating technical specifications

  1. Evaluation of primary coolant leaks and assessment of detection methods

    International Nuclear Information System (INIS)

    Cassette, P.; Giroux, C.; Roche, H.; Seveon, J.J.

    1984-11-01

    A review of French PWR situation concerning primary coolant leaks is presented, including a description of operating technical specifications, of the collecting system of primary coolant leakage into the containment and of the detection methods. It is mainly based on a compilation over three years, 1981 to 1983, of almost all occurred leaks, their natures, causes, consequences and methods used for their detection. By analysing these data it is possible to evaluate the efficiency of the primary coolant leak detection system and the problems raised by the compliance with the criteria defined in the operating technical specifications

  2. Rapid Methods for the Detection of Foodborne Bacterial Pathogens: Principles, Applications, Advantages and Limitations

    Directory of Open Access Journals (Sweden)

    Law eJodi Woan-Fei

    2015-01-01

    Full Text Available The incidence of foodborne diseases has increased over the years and resulted in major public health problem globally. Foodborne pathogens can be found in various foods and it is important to detect foodborne pathogens to provide safe food supply and to prevent foodborne diseases. The conventional methods used to detect foodborne pathogen are time consuming and laborious. Hence, a variety of methods have been developed for rapid detection of foodborne pathogens as it is required in many food analyses. Rapid detection methods can be categorized into nucleic acid-based, biosensor-based and immunological-based methods. This review emphasizes on the principles and application of recent rapid methods for the detection of foodborne bacterial pathogens. Detection methods included are simple polymerase chain reaction (PCR, multiplex PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA, loop-mediated isothermal amplification (LAMP and oligonucleotide DNA microarray which classified as nucleic acid-based methods; optical, electrochemical and mass-based biosensors which classified as biosensor-based methods; enzyme-linked immunosorbent assay (ELISA and lateral flow immunoassay which classified as immunological-based methods. In general, rapid detection methods are generally time-efficient, sensitive, specific and labor-saving. The developments of rapid detection methods are vital in prevention and treatment of foodborne diseases.

  3. Pairing field methods to improve inference in wildlife surveys while accommodating detection covariance.

    Science.gov (United States)

    Clare, John; McKinney, Shawn T; DePue, John E; Loftin, Cynthia S

    2017-10-01

    It is common to use multiple field sampling methods when implementing wildlife surveys to compare method efficacy or cost efficiency, integrate distinct pieces of information provided by separate methods, or evaluate method-specific biases and misclassification error. Existing models that combine information from multiple field methods or sampling devices permit rigorous comparison of method-specific detection parameters, enable estimation of additional parameters such as false-positive detection probability, and improve occurrence or abundance estimates, but with the assumption that the separate sampling methods produce detections independently of one another. This assumption is tenuous if methods are paired or deployed in close proximity simultaneously, a common practice that reduces the additional effort required to implement multiple methods and reduces the risk that differences between method-specific detection parameters are confounded by other environmental factors. We develop occupancy and spatial capture-recapture models that permit covariance between the detections produced by different methods, use simulation to compare estimator performance of the new models to models assuming independence, and provide an empirical application based on American marten (Martes americana) surveys using paired remote cameras, hair catches, and snow tracking. Simulation results indicate existing models that assume that methods independently detect organisms produce biased parameter estimates and substantially understate estimate uncertainty when this assumption is violated, while our reformulated models are robust to either methodological independence or covariance. Empirical results suggested that remote cameras and snow tracking had comparable probability of detecting present martens, but that snow tracking also produced false-positive marten detections that could potentially substantially bias distribution estimates if not corrected for. Remote cameras detected marten

  4. Determination of detection limits for a VPD ICPMS method of analysis

    International Nuclear Information System (INIS)

    Badard, M.; Veillerot, M.

    2007-01-01

    This training course report presents the different methods of detection and quantifying of metallic impurities in semiconductors. One of the most precise technique is the collection of metal impurities by vapor phase decomposition (VPD) followed by their analysis by ICPMS (inductively coupled plasma mass spectrometry). The study shows the importance of detection limits in the domain of chemical analysis and the way to determine them for the ICPMS analysis. The results found on detection limits are excellent. Even if the detection limits reached with ICPMS performed after manual or automatic VPD are much higher than detection limits of ICPMS alone, this method remains one of the most sensible for ultra-traces analysis. (J.S.)

  5. Bayesian Methods for Radiation Detection and Dosimetry

    International Nuclear Information System (INIS)

    Peter G. Groer

    2002-01-01

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed compartmental activities. From the estimated probability densities of the model parameters we were able to derive the densities for compartmental activities for a two compartment catenary model at different times. We also calculated the average activities and their standard deviation for a simple two compartment model

  6. A multi points ultrasonic detection method for material flow of belt conveyor

    Science.gov (United States)

    Zhang, Li; He, Rongjun

    2018-03-01

    For big detection error of single point ultrasonic ranging technology used in material flow detection of belt conveyor when coal distributes unevenly or is large, a material flow detection method of belt conveyor is designed based on multi points ultrasonic counter ranging technology. The method can calculate approximate sectional area of material by locating multi points on surfaces of material and belt, in order to get material flow according to running speed of belt conveyor. The test results show that the method has smaller detection error than single point ultrasonic ranging technology under the condition of big coal with uneven distribution.

  7. Failed fuel detection method

    International Nuclear Information System (INIS)

    Utamura, Motoaki; Urata, Megumu.

    1976-01-01

    Object: To detect failed fuel element in a reactor with high precision by measuring the radioactivity concentrations for more than one nuclides of fission products ( 131 I and 132 I, for example) contained in each sample of coolant in fuel channel. Method: The radioactivity concentrations in the sampled coolant are obtained from gamma spectra measured by a pulse height analyser after suitable cooling periods according to the half-lives of the fission products to be measured. The first measurement for 132 I is made in two hours after sampling, and the second for 131 I is started one day after the sampling. Fuel element corresponding to the high radioactivity concentrations for both 131 I and 132 I is expected with certainty to have failed

  8. Sleep Spindles as an Electrographic Element: Description and Automatic Detection Methods

    Directory of Open Access Journals (Sweden)

    Dorothée Coppieters ’t Wallant

    2016-01-01

    Full Text Available Sleep spindle is a peculiar oscillatory brain pattern which has been associated with a number of sleep (isolation from exteroceptive stimuli, memory consolidation and individual characteristics (intellectual quotient. Oddly enough, the definition of a spindle is both incomplete and restrictive. In consequence, there is no consensus about how to detect spindles. Visual scoring is cumbersome and user dependent. To analyze spindle activity in a more robust way, automatic sleep spindle detection methods are essential. Various algorithms were developed, depending on individual research interest, which hampers direct comparisons and meta-analyses. In this review, sleep spindle is first defined physically and topographically. From this general description, we tentatively extract the main characteristics to be detected and analyzed. A nonexhaustive list of automatic spindle detection methods is provided along with a description of their main processing principles. Finally, we propose a technique to assess the detection methods in a robust and comparable way.

  9. Main Achievements 2003-2004 - Interdisciplinary Research - Radiation detection methods for health, earth and environmental sciences - Detection methods in gas chromatography

    International Nuclear Information System (INIS)

    2005-01-01

    Detection methods in gas chromatography are under development, especially ultra-sensitive gas chromatography detection methods to monitor the atmosphere (with respect to gases active in the destruction of the Earth ozone layer). A new chromatographic method has been elaborated for Ne determination, and technique for determination of Ar and N 2 in groundwater has been significantly improved. Measurements of neon are performed by means of a chromatographic system equipped with a helium ionization detector (PD-HID) doped with neon pulse discharge, working with a modified sample introduction system. The Ar and N 2 contents are determined by a thermal-conductivity detector (TCD). The problem of separation of Ar from O 2 has been solved by catalytic removal of the latter from the sample. The measurement reproducibility is 1%, 2% and 0.5% for Ar, Ne and N 2 , respectively. Both methods were successfully applied in measurements of groundwaters in the Cracow area. The excess air contents are in the range of about 1 to 3 cm 3 STP L-1. The values of recharge temperatures for Holocen water agree reasonably well with the yearly mean long-term surface air temperature (8.2 o C)

  10. Minimum detectable gas concentration performance evaluation method for gas leak infrared imaging detection systems.

    Science.gov (United States)

    Zhang, Xu; Jin, Weiqi; Li, Jiakun; Wang, Xia; Li, Shuo

    2017-04-01

    Thermal imaging technology is an effective means of detecting hazardous gas leaks. Much attention has been paid to evaluation of the performance of gas leak infrared imaging detection systems due to several potential applications. The minimum resolvable temperature difference (MRTD) and the minimum detectable temperature difference (MDTD) are commonly used as the main indicators of thermal imaging system performance. This paper establishes a minimum detectable gas concentration (MDGC) performance evaluation model based on the definition and derivation of MDTD. We proposed the direct calculation and equivalent calculation method of MDGC based on the MDTD measurement system. We build an experimental MDGC measurement system, which indicates the MDGC model can describe the detection performance of a thermal imaging system to typical gases. The direct calculation, equivalent calculation, and direct measurement results are consistent. The MDGC and the minimum resolvable gas concentration (MRGC) model can effectively describe the performance of "detection" and "spatial detail resolution" of thermal imaging systems to gas leak, respectively, and constitute the main performance indicators of gas leak detection systems.

  11. Isotopic method of leaks detection in oil pipelines

    International Nuclear Information System (INIS)

    Listwam, W.; Mottl, J.

    1974-01-01

    Isotopic method of leaks detection in oil pipelines of diameter 200-800 mm is described. Tracer is injected into pipeline in the form of CH 3 Br 82 . After few hours one or two detectors are passed through pipeline to detect leaks. Detector set consists of scintillation radiometer with Na I/Tl crystal, electronic blecks with one-channel analyzer, recorder and storage batteries. Detector set is built on integrated circuits. (Z.M.)

  12. Doppler method leak detection for LMFBR steam generators. Pt. 2. Detection characteristics of bubble in-water using large scale SG model

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi

    2000-01-01

    To prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of a fast breeder reactor (FBR), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method was developed. Previous studies have revealed that, in practical steam generators, the active acoustic method can detect bubbles of 10 l/s within 10 seconds. However to prevent the expansion of damage to neighboring tubes, it is necessary to detect smaller leakages of water from the heat transfer tubes. The Doppler method is designed to detect small leakages and to find the source of a leak before damage spreads to neighboring tubes. The detection sensitivity of the Doppler method and the influence of background noise were investigated experimentally. In-water experiments were performed using an SG full-sector model that simulates actual SGs. The results show that the Doppler method can detect bubbles of 0.1 l/s (equivalent to a water leak rate of about 0.1 g/s) within a few seconds and that the background noise has little effect on water leak detection performance. The Doppler method thus has great potential for the detection of water leakage in SGs. (author)

  13. Changes of hemoglobin and hematocrit in elderly patients receiving lower joint arthroplasty without allogeneic blood transfusion.

    Science.gov (United States)

    Zhou, Qi; Zhou, Yiqin; Wu, Haishan; Wu, Yuli; Qian, Qirong; Zhao, Hui; Zhu, Yunli; Fu, Peiliang

    2015-01-05

    It has rarely been reported about the changes of hemoglobin (Hb) and hematocrit (Hct) in elderly patients receiving total knee arthroplasty (TKA) or total hip arthroplasty (THA). This study aimed to evaluate the changes of Hb and Hct after TKA or THA in elderly patients, and analyze its relationship with sex and type of arthroplasty. This is a prospective cohort study, including 107 patients receiving TKA or THA without allogeneic blood transfusion. There were 54 males and 53 females, with a mean age of 69.42 years. Levels of Hb and Hct were examined preoperatively and during the 6 months follow-up after operation. Levels of Hb and Hct decreased postoperatively and reached their minimum points on postoperative day 4. Thereafter, Hb and Hct recovered to their preoperative levels within 6-12 weeks. No significant differences in the levels of Hb and Hct were noticed between different sexes. THA patients showed significantly greater drop in Hb and Hct than TKA patients in the first 4 days postoperatively (P < 0.05). Levels of Hb and Hct decreased during the first 4 days after arthroplasty and gradually returned to their normal levels within 6-12 weeks postoperatively. THA may be associated with higher postoperative blood loss than TKA.

  14. Method of Detecting Coliform Bacteria and Escherichia Coli Bacteria from Reflected Light

    Science.gov (United States)

    Vincent, Robert (Inventor)

    2013-01-01

    The present invention relates to a method of detecting coliform bacteria in water from reflected light and a method of detecting Eschericha Coli bacteria in water from reflected light, and also includes devices for the measurement, calculation and transmission of data relating to that method.

  15. A method for detecting hydrophobic patches protein

    NARCIS (Netherlands)

    Lijnzaad, P.; Berendsen, H.J.C.; Argos, P.

    1996-01-01

    A method for the detection of hydrophobic patches on the surfaces of protein tertiary structures is presented, it delineates explicit contiguous pieces of surface of arbitrary size and shape that consist solely of carbon and sulphur atoms using a dot representation of the solvent-accessible surface,

  16. Ultrasonic defect detection method for socket welding joint

    International Nuclear Information System (INIS)

    Tominaga, Masaaki; Matsuo, Toshiyuki; Ueno, Akihiro; Watanabe, Kunimichi; Kawamata, Kunio.

    1995-01-01

    The present invention provides a method of detecting defects over a wide range of a socket weld portion of various kinds of pipelines used, for example, in a nuclear power plant. Namely, an inclined probe is disposed to a jig for detecting defects by ultrasonic waves. This is rotated at least by one turn along the peripheral surface of the material to be detected such as weld tube joints. Defects of weld portion of the material can be detected automatically by using ultrasonic waves during the rotation. The inclined probe for detecting defects by ultrasonic waves comprises a transmission portion having a planar transmittance oscillator disposed to a wedge on the transmission side and a receiving portion comprising a planar receiving oscillator disposed to a wedge on the receiving side. With such a constitution, ultrasonic waves are emitted from the transmission portion to the defect detection portion in the welded portion. If a defect is present, defective echo is reflected to the receiving portion disposed ahead of the probe. Since the defective echo changes depending on the height of the detective portion, the estimation of the height of the defect can be facilitated. (I.S.)

  17. Remote sensing image ship target detection method based on visual attention model

    Science.gov (United States)

    Sun, Yuejiao; Lei, Wuhu; Ren, Xiaodong

    2017-11-01

    The traditional methods of detecting ship targets in remote sensing images mostly use sliding window to search the whole image comprehensively. However, the target usually occupies only a small fraction of the image. This method has high computational complexity for large format visible image data. The bottom-up selective attention mechanism can selectively allocate computing resources according to visual stimuli, thus improving the computational efficiency and reducing the difficulty of analysis. Considering of that, a method of ship target detection in remote sensing images based on visual attention model was proposed in this paper. The experimental results show that the proposed method can reduce the computational complexity while improving the detection accuracy, and improve the detection efficiency of ship targets in remote sensing images.

  18. Pornographic information of Internet views detection method based on the connected areas

    Science.gov (United States)

    Wang, Huibai; Fan, Ajie

    2017-01-01

    Nowadays online porn video broadcasting and downloading is very popular. In view of the widespread phenomenon of Internet pornography, this paper proposed a new method of pornographic video detection based on connected areas. Firstly, decode the video into a serious of static images and detect skin color on the extracted key frames. If the area of skin color reaches a certain threshold, use the AdaBoost algorithm to detect the human face. Judge the connectivity of the human face and the large area of skin color to determine whether detect the sensitive area finally. The experimental results show that the method can effectively remove the non-pornographic videos contain human who wear less. This method can improve the efficiency and reduce the workload of detection.

  19. Methods for detecting the environmental coccoid form of Helicobacter pylori

    Directory of Open Access Journals (Sweden)

    Mahnaz eMazaheri Assadi

    2015-05-01

    Full Text Available Helicobacter pylori is recognized as the most common pathogen to cause gastritis, peptic and duodenal ulcers, and gastric cancer. The organisms are found in two forms: 1 spiral-shaped bacillus and 2 coccoid. H. pylori coccoid form, generally found in the environment, is the transformed form of the normal spiral-shaped bacillus after exposed to water or adverse environmental conditions such as exposure to sub-inhibitory concentrations of antimicrobial agents. The putative infectious capability and the viability of H. pylori under environmental conditions are controversial. This disagreement is partially due to the fact of lack in detecting the coccoid form of H. pylori in the environment. Accurate and effective detection methods of H. pylori will lead to rapid treatment and disinfection, and less human health damages and reduction in health care costs. In this review, we provide a brief introduction to H. pylori environmental coccoid forms, their transmission and detection methods. We further discuss the use of these detection methods including their accuracy and efficiency.

  20. Emergency First Responders' Experience with Colorimetric Detection Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandra L. Fox; Keith A. Daum; Carla J. Miller; Marnie M. Cortez

    2007-10-01

    Nationwide, first responders from state and federal support teams respond to hazardous materials incidents, industrial chemical spills, and potential weapons of mass destruction (WMD) attacks. Although first responders have sophisticated chemical, biological, radiological, and explosive detectors available for assessment of the incident scene, simple colorimetric detectors have a role in response actions. The large number of colorimetric chemical detection methods available on the market can make the selection of the proper methods difficult. Although each detector has unique aspects to provide qualitative or quantitative data about the unknown chemicals present, not all detectors provide consistent, accurate, and reliable results. Included here, in a consumer-report-style format, we provide “boots on the ground” information directly from first responders about how well colorimetric chemical detection methods meet their needs in the field and how they procure these methods.

  1. Method and device for detecting radiatons

    International Nuclear Information System (INIS)

    Borel, J.; Goascoz, V.

    1979-01-01

    The method consists in fabricating an MOS transistor comprising a drain region and a source region separated from each other by a bulk region of opposite doping type relative to the first two regions, in delivering the radiation to be detected into the carrier-collection region of the MOS transistor, in leaving the bulk region at a floating potential and in collecting the drain-source current of the transistor

  2. Infrared video based gas leak detection method using modified FAST features

    Science.gov (United States)

    Wang, Min; Hong, Hanyu; Huang, Likun

    2018-03-01

    In order to detect the invisible leaking gas that is usually dangerous and easily leads to fire or explosion in time, many new technologies have arisen in the recent years, among which the infrared video based gas leak detection is widely recognized as a viable tool. However, all the moving regions of a video frame can be detected as leaking gas regions by the existing infrared video based gas leak detection methods, without discriminating the property of each detected region, e.g., a walking person in a video frame may be also detected as gas by the current gas leak detection methods.To solve this problem, we propose a novel infrared video based gas leak detection method in this paper, which is able to effectively suppress strong motion disturbances.Firstly, the Gaussian mixture model(GMM) is used to establish the background model.Then due to the observation that the shapes of gas regions are different from most rigid moving objects, we modify the Features From Accelerated Segment Test (FAST) algorithm and use the modified FAST (mFAST) features to describe each connected component. In view of the fact that the statistical property of the mFAST features extracted from gas regions is different from that of other motion regions, we propose the Pixel-Per-Points (PPP) condition to further select candidate connected components.Experimental results show that the algorithm is able to effectively suppress most strong motion disturbances and achieve real-time leaking gas detection.

  3. Method for the detection of Salmonella enterica serovar Enteritidis

    Science.gov (United States)

    Agron, Peter G.; Andersen, Gary L.; Walker, Richard L.

    2008-10-28

    Described herein is the identification of a novel Salmonella enterica serovar Enteritidis locus that serves as a marker for DNA-based identification of this bacterium. In addition, three primer pairs derived from this locus that may be used in a nucleotide detection method to detect the presence of the bacterium are also disclosed herein.

  4. Radiometric method for the rapid detection of Leptospira organisms

    International Nuclear Information System (INIS)

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-01-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with 14 C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques

  5. Steganalytic methods for the detection of histogram shifting data-hiding schemes

    OpenAIRE

    Lerch Hostalot, Daniel

    2011-01-01

    In this paper, some steganalytic techniques designed to detect the existence of hidden messages using histogram shifting methods are presented. Firstly, some techniques to identify specific methods of histogram shifting, based on visible marks on the histogram or abnormal statistical distributions are suggested. Then, we present a general technique capable of detecting all histogram shifting techniques analyzed. This technique is based on the effect of histogram shifting methods on the "volat...

  6. Method for radar detection of persons wearing wires

    OpenAIRE

    Fox, William P.

    2014-01-01

    8,730,098 B1 Methods are described for radar detection of persons wearing wires using radar spectra data including the vertical polarization (VV) radar cross section and the horizontal polarization (HH) radar cross section for a person. In one embodiment, the ratio of the vertical polarization (VV) radar cross section to the horizontal polarization (HH) radar cross section for a person is compared to a detection threshold to determine whether the person is wearing wire...

  7. Crack detecting method

    International Nuclear Information System (INIS)

    Narita, Michiko; Aida, Shigekazu

    1998-01-01

    A penetration liquid or a slow drying penetration liquid prepared by mixing a penetration liquid and a slow drying liquid is filled to the inside of an artificial crack formed to a member to be detected such as of boiler power generation facilities and nuclear power facilities. A developing liquid is applied to the periphery of the artificial crack on the surface of a member to be detected. As the slow-drying liquid, an oil having a viscosity of 56 is preferably used. Loads are applied repeatedly to the member to be detected, and when a crack is caused to the artificial crack, the permeation liquid penetrates into the crack. The penetration liquid penetrated into the crack is developed by the developing liquid previously coated to the periphery of the artificial crack of the surface of the member to be detected. When a crack is caused, since the crack is developed clearly even if it is a small opening, the crack can be recognized visually reliably. (I.N.)

  8. Development of a microbiological irradiation detection method for spices

    International Nuclear Information System (INIS)

    Koshikawa, T.; Takekawa, T.; Miyahara, M.

    2009-01-01

    In order to judge whether certain spices had been irradiated or not, we examined the possibility of developing a method based on the microbiological examination of spices. We used the total bacteria count in conjunction with the ratio of B. megaterium and B. cereus to the total bacteria count. The examination results of 6 kinds of spices with or without irradiation (black pepper, white pepper, coriander, paprika, ginger and turmeric), were as follows. Total bacteria counts over 10E5 CFU/g indicated that the samples were 'unirradiated'. When the total bacteria count was less than 10E5 CFU/g, and the ratio of B. megaterium and B. cereus to the total count was more than 30%, a history of irradiation of the samples was indicated. When ratios of B. megaterium and B. cereus were less than 30% and the total bacteria count was also less than 10E5 CFU/g, 'uncertainty' of irradiation was indicated. In this case, it would be possible to confirm whether spices were 'unirradiated' or 'irradiated' by using another detection method. This detection method was applicable to other spices except for paprika. The samples judged as 'irradiated' by using this detection method, surely proved to have a history of irradiation treatment

  9. Earth analysis methods, subsurface feature detection methods, earth analysis devices, and articles of manufacture

    Science.gov (United States)

    West, Phillip B [Idaho Falls, ID; Novascone, Stephen R [Idaho Falls, ID; Wright, Jerry P [Idaho Falls, ID

    2011-09-27

    Earth analysis methods, subsurface feature detection methods, earth analysis devices, and articles of manufacture are described. According to one embodiment, an earth analysis method includes engaging a device with the earth, analyzing the earth in a single substantially lineal direction using the device during the engaging, and providing information regarding a subsurface feature of the earth using the analysis.

  10. Development of detection methods for irradiated foods - Detection method for radiolytic products of irradiated foods

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyong Su; Kim, Sun Min; Park, Eun Ryong; Lee, Hae Jung; Kim, Eun Ah; Jo, Jung Ok [Chosun University, Kwangju (Korea)

    1999-04-01

    Meat (beef, pork, chicken) and nut (sesame, perilla, black sesame, peanut) were irradiated with /sup 60/Co gamma-ray. A process to detect radiation-induced hydrocarbons and 2-alkylcyclobutanones includes the extraction of fat from meat and nut, separation of hydrocarbons and 2-alkylcyclobutanones with a florisil column and identification of GC/MS methods. Concentrations of the produced hydrocarbons and 2-alkylcyclobutanones tended to increase linearly with the dose levels of irradiation in beef, pork and chicken, while concentrations of radiation-induced hydrocarbons were different individually at the same dose level. In meat, hydrocarbons and 2-alkylcyclobutanones originated from oleic acid were found in a large amount. The concentrations of radiation-induced hydrocarbons were relatively constant during 16 weeks. In nut, hydrocarbons originated from oleic acid and linoleic acid were the major compounds whereas results of perilla was similar to meat. Radiation-induced hydrocarbons were increased linearly with the irradiation dose and remarkably detected at 0.5 kGy and over. 44 refs., 30 figs., 14 tabs. (Author)

  11. Detection of forced oscillations in power systems with multichannel methods

    Energy Technology Data Exchange (ETDEWEB)

    Follum, James D. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)

    2015-09-30

    The increasing availability of high fidelity, geographically dispersed measurements in power systems improves the ability of researchers and engineers to study dynamic behaviors in the grid. One such behavior that is garnering increased attention is the presence of forced oscillations. Power system engineers are interested in forced oscillations because they are often symptomatic of the malfunction or misoperation of equipment. Though the resulting oscillation is not always large in amplitude, the root cause may be serious. In this report, multi-channel forced oscillation detection methods are developed. These methods leverage previously developed detection approaches based on the periodogram and spectral-coherence. Making use of geographically distributed channels of data is shown to improved detection performance and shorten the delay before an oscillation can be detected in the online environment. Results from simulated and measured power system data are presented.

  12. Method of Multiobject Detecting and Tracking Based on DM643

    Directory of Open Access Journals (Sweden)

    Yitao Liang

    2014-01-01

    Full Text Available The technology of moving objects detection has become an important research subject for its extensive application prospect. In this paper, it is presented that interframe difference algorithm and background difference algorithm are combined to update the background. The algorithm can deal with the flaw of background difference algorithm. The mathematical morphology method is employed to denoise the image, which may be helpful to improve the accuracy of the detection. The Pyramid algorithm is used to compress each frame data of video sequence. Then, the detecting and tracking of moving objects are tested on the hardware platform (DM643 and the software frame (RF5. The running speed is about 3 times faster than before. The result shows that the accuracy demanded by the detection is met. This method can provide a useful reference for similar application.

  13. Improved Ordinary Measure and Image Entropy Theory based intelligent Copy Detection Method

    Directory of Open Access Journals (Sweden)

    Dengpan Ye

    2011-10-01

    Full Text Available Nowadays, more and more multimedia websites appear in social network. It brings some security problems, such as privacy, piracy, disclosure of sensitive contents and so on. Aiming at copyright protection, the copy detection technology of multimedia contents becomes a hot topic. In our previous work, a new computer-based copyright control system used to detect the media has been proposed. Based on this system, this paper proposes an improved media feature matching measure and an entropy based copy detection method. The Levenshtein Distance was used to enhance the matching degree when using for feature matching measure in copy detection. For entropy based copy detection, we make a fusion of the two features of entropy matrix of the entropy feature we extracted. Firstly,we extract the entropy matrix of the image and normalize it. Then, we make a fusion of the eigenvalue feature and the transfer matrix feature of the entropy matrix. The fused features will be used for image copy detection. The experiments show that compared to use these two kinds of features for image detection singly, using feature fusion matching method is apparent robustness and effectiveness. The fused feature has a high detection for copy images which have been received some attacks such as noise, compression, zoom, rotation and so on. Comparing with referred methods, the method proposed is more intelligent and can be achieved good performance.

  14. Radiometric method for the rapid detection of Leptospira organisms

    Energy Technology Data Exchange (ETDEWEB)

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-02-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with /sup 14/C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques.

  15. Exploring three faint source detections methods for aperture synthesis radio images

    Science.gov (United States)

    Peracaula, M.; Torrent, A.; Masias, M.; Lladó, X.; Freixenet, J.; Martí, J.; Sánchez-Sutil, J. R.; Muñoz-Arjonilla, A. J.; Paredes, J. M.

    2015-04-01

    Wide-field radio interferometric images often contain a large population of faint compact sources. Due to their low intensity/noise ratio, these objects can be easily missed by automated detection methods, which have been classically based on thresholding techniques after local noise estimation. The aim of this paper is to present and analyse the performance of several alternative or complementary techniques to thresholding. We compare three different algorithms to increase the detection rate of faint objects. The first technique consists of combining wavelet decomposition with local thresholding. The second technique is based on the structural behaviour of the neighbourhood of each pixel. Finally, the third algorithm uses local features extracted from a bank of filters and a boosting classifier to perform the detections. The methods' performances are evaluated using simulations and radio mosaics from the Giant Metrewave Radio Telescope and the Australia Telescope Compact Array. We show that the new methods perform better than well-known state of the art methods such as SEXTRACTOR, SAD and DUCHAMP at detecting faint sources of radio interferometric images.

  16. An affordable and easy-to-use diagnostic method for keratoconus detection using a smartphone

    Science.gov (United States)

    Askarian, Behnam; Tabei, Fatemehsadat; Askarian, Amin; Chong, Jo Woon

    2018-02-01

    Recently, smartphones are used for disease diagnosis and healthcare. In this paper, we propose a novel affordable diagnostic method of detecting keratoconus using a smartphone. Keratoconus is usually detected in clinics with ophthalmic devices, which are large, expensive and not portable, and need to be operated by trained technicians. However, our proposed smartphone-based eye disease detection method is small, affordable, portable, and it can be operated by patients in a convenient way. The results show that the proposed keratoconus detection method detects severe, advanced, and moderate keratoconus with accuracies of 93%, 86%, 67%, respectively. Due to its convenience with these accuracies, the proposed keratoconus detection method is expected to be applied in detecting keratoconus at an earlier stage in an affordable way.

  17. White-Nose Syndrome Disease Severity and a Comparison of Diagnostic Methods.

    Science.gov (United States)

    McGuire, Liam P; Turner, James M; Warnecke, Lisa; McGregor, Glenna; Bollinger, Trent K; Misra, Vikram; Foster, Jeffrey T; Frick, Winifred F; Kilpatrick, A Marm; Willis, Craig K R

    2016-03-01

    White-nose syndrome is caused by the fungus Pseudogymnoascus destructans and has killed millions of hibernating bats in North America but the pathophysiology of the disease remains poorly understood. Our objectives were to (1) assess non-destructive diagnostic methods for P. destructans infection compared to histopathology, the current gold-standard, and (2) to evaluate potential metrics of disease severity. We used data from three captive inoculation experiments involving 181 little brown bats (Myotis lucifugus) to compare histopathology, quantitative PCR (qPCR), and ultraviolet fluorescence as diagnostic methods of P. destructans infection. To assess disease severity, we considered two histology metrics (wing area with fungal hyphae, area of dermal necrosis), P. destructans fungal load (qPCR), ultraviolet fluorescence, and blood chemistry (hematocrit, sodium, glucose, pCO2, and bicarbonate). Quantitative PCR was most effective for early detection of P. destructans, while all three methods were comparable in severe infections. Correlations among hyphae and necrosis scores, qPCR, ultraviolet fluorescence, blood chemistry, and hibernation duration indicate a multi-stage pattern of disease. Disruptions of homeostasis occurred rapidly in late hibernation. Our results provide valuable information about the use of non-destructive techniques for monitoring, and provide novel insight into the pathophysiology of white-nose syndrome, with implications for developing and implementing potential mitigation strategies.

  18. Full-waveform detection of non-impulsive seismic events based on time-reversal methods

    Science.gov (United States)

    Solano, Ericka Alinne; Hjörleifsdóttir, Vala; Liu, Qinya

    2017-12-01

    We present a full-waveform detection method for non-impulsive seismic events, based on time-reversal principles. We use the strain Green's tensor as a matched filter, correlating it with continuous observed seismograms, to detect non-impulsive seismic events. We show that this is mathematically equivalent to an adjoint method for detecting earthquakes. We define the detection function, a scalar valued function, which depends on the stacked correlations for a group of stations. Event detections are given by the times at which the amplitude of the detection function exceeds a given value relative to the noise level. The method can make use of the whole seismic waveform or any combination of time-windows with different filters. It is expected to have an advantage compared to traditional detection methods for events that do not produce energetic and impulsive P waves, for example glacial events, landslides, volcanic events and transform-fault earthquakes for events which velocity structure along the path is relatively well known. Furthermore, the method has advantages over empirical Greens functions template matching methods, as it does not depend on records from previously detected events, and therefore is not limited to events occurring in similar regions and with similar focal mechanisms as these events. The method is not specific to any particular way of calculating the synthetic seismograms, and therefore complicated structural models can be used. This is particularly beneficial for intermediate size events that are registered on regional networks, for which the effect of lateral structure on the waveforms can be significant. To demonstrate the feasibility of the method, we apply it to two different areas located along the mid-oceanic ridge system west of Mexico where non-impulsive events have been reported. The first study area is between Clipperton and Siqueiros transform faults (9°N), during the time of two earthquake swarms, occurring in March 2012 and May

  19. Study on UPF Harmonic Current Detection Method Based on DSP

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, H J [Northwestern Polytechnical University, Xi' an 710072 (China); Pang, Y F [Xi' an University of Technology, Xi' an 710048 (China); Qiu, Z M [Xi' an University of Technology, Xi' an 710048 (China); Chen, M [Northwestern Polytechnical University, Xi' an 710072 (China)

    2006-10-15

    Unity power factor (UPF) harmonic current detection method applied to active power filter (APF) is presented in this paper. The intention of this method is to make nonlinear loads and active power filter in parallel to be an equivalent resistance. So after compensation, source current is sinusoidal, and has the same shape of source voltage. Meanwhile, there is no harmonic in source current, and the power factor becomes one. The mathematic model of proposed method and the optimum project for equivalent low pass filter in measurement are presented. Finally, the proposed detection method applied to a shunt active power filter experimental prototype based on DSP TMS320F2812 is developed. Simulation and experiment results indicate the method is simple and easy to implement, and can obtain the real-time calculation of harmonic current exactly.

  20. Statistical methods for anomaly detection in the complex process; Methodes statistiques de detection d'anomalies de fonctionnement dans les processus complexes

    Energy Technology Data Exchange (ETDEWEB)

    Al Mouhamed, Mayez

    1977-09-15

    In a number of complex physical systems the accessible signals are often characterized by random fluctuations about a mean value. The fluctuations (signature) often transmit information about the state of the system that the mean value cannot predict. This study is undertaken to elaborate statistical methods of anomaly detection on the basis of signature analysis of the noise inherent in the process. The algorithm presented first learns the characteristics of normal operation of a complex process. Then it detects small deviations from the normal behavior. The algorithm can be implemented in a medium-sized computer for on line application. (author) [French] Dans de nombreux systemes physiques complexes les grandeurs accessibles a l'homme sont souvent caracterisees par des fluctuations aleatoires autour d'une valeur moyenne. Les fluctuations (signatures) transmettent souvent des informations sur l'etat du systeme que la valeur moyenne ne peut predire. Cette etude est entreprise pour elaborer des methodes statistiques de detection d'anomalies de fonctionnement sur la base de l'analyse des signatures contenues dans les signaux de bruit provenant du processus. L'algorithme presente est capable de: 1/ Apprendre les caracteristiques des operations normales dans un processus complexe. 2/ Detecter des petites deviations par rapport a la conduite normale du processus. L'algorithme peut etre implante sur un calculateur de taille moyenne pour les applications en ligne. (auteur)

  1. Review of methods of detection of oil pollution in the sea

    Energy Technology Data Exchange (ETDEWEB)

    Gurgul, H; Pawlak, B

    1981-01-01

    In connection with the necessary of detection, recognition, and identification of oil spills in the sea, existing and prospective contactless methods of detecting oil on the water surface are reviewed, including such methods as optical (in IR, visible, and UV, including lasers, bands), radar with the use of fluorescence and interference phenomena; aerial and space photography and shooting. Parameters of instruments that use the optical and radar methods, including CO/sub 2/-, nitrogen and helium-cadmium lasers, are presented.

  2. Methods and Algorithms for Detecting Objects in Video Files

    Directory of Open Access Journals (Sweden)

    Nguyen The Cuong

    2018-01-01

    Full Text Available Video files are files that store motion pictures and sounds like in real life. In today's world, the need for automated processing of information in video files is increasing. Automated processing of information has a wide range of application including office/home surveillance cameras, traffic control, sports applications, remote object detection, and others. In particular, detection and tracking of object movement in video file plays an important role. This article describes the methods of detecting objects in video files. Today, this problem in the field of computer vision is being studied worldwide.

  3. DNA based methods used for characterization and detection of food ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-05-04

    May 4, 2009 ... selective medium followed by plating in differential agar medium ... result. Biochemical and immunological methods for the detection require substantial amount of pure culture whereas .... biotin (chemiluminescent) probes are detected visually. It ..... are also gathering special attention due to their covalent.

  4. Technical improvement and development of automatic detection method for genomic mutation

    International Nuclear Information System (INIS)

    Yamada, Kiyomi; Takai, Setsuo; Togashi, Chikako; Itami, Jun

    1999-01-01

    Fluorescent in situ hybridization (FISH) method was improved to estimate the dose of radiation exposure. Cleavage of DNA molecules in lymphocyte was used as the detection parameter and the procedures for preparation of samples suitable for atomic force microscopy and laser microscopy were developed. When ordinal primers on the market were used for PCR, the products were generally too small (about 200 b.p.) for detection by FISH method. Therefore, dATP and biotin-labeled dUTP were linked to its 3'-end by treatment with TdT for 2 hours, resulting that the mean length of PCR products was ca. 1.5 Kb. After hybridization using this prove, signal amplification was carried out according to biotin-avidin detection method. Thus, fluorescent signals on chromosomes could be easily detected. When three primers, D6S105, D6S291 and D6S282 were used as primer, fluorescent signal was detectable at 3 sites on chromatin fiber. These results indicate that this method is available for the analysis of cleavage of chromosomes. However, the backgrounds were much varied depending on the way to wash the preparation after incubation with fluorescent particle to form biotin-avidin binding. Therefore, further improvement of this method was necessary to apply in practice. When chromosomes 13, 14 and 15 from lymphocytes exposed to X-ray were used as test samples, it was demonstrated that radio-sensitivity was variable depending on the contents of R band in each chromosome. (M.N.)

  5. Research progress in machine learning methods for gene-gene interaction detection.

    Science.gov (United States)

    Peng, Zhe-Ye; Tang, Zi-Jun; Xie, Min-Zhu

    2018-03-20

    Complex diseases are results of gene-gene and gene-environment interactions. However, the detection of high-dimensional gene-gene interactions is computationally challenging. In the last two decades, machine-learning approaches have been developed to detect gene-gene interactions with some successes. In this review, we summarize the progress in research on machine learning methods, as applied to gene-gene interaction detection. It systematically examines the principles and limitations of the current machine learning methods used in genome wide association studies (GWAS) to detect gene-gene interactions, such as neural networks (NN), random forest (RF), support vector machines (SVM) and multifactor dimensionality reduction (MDR), and provides some insights on the future research directions in the field.

  6. Methods and tools to detect thermal noise in fast reactors

    International Nuclear Information System (INIS)

    Motta, M.; Giovannini, R.

    1985-07-01

    The Specialists' Meeting on ''Methods and Tools to Detect Thermal Noise in Fast Reactors'' was held in Bologna on 8-10 October 1984. The meeting was hosted by the ENEA and was sponsored by the IAEA on the recommendation of the International Working Group on Fast Reactors. 17 participants attended the meeting from France, the Federal Republic of Germany, Italy, Japan, the United Kingdom, Joint Research Centre of CEC and from IAEA. The meeting was presided over by Prof. Mario Motta of Italy. The purpose of the meeting was to review and discuss methods and tools for temperature noise detection and related analysis as a potential means for detecting local blockages in fuel and blanket subassemblies and other faults in LMFBR. The meeting was divided into four technical sessions as follows: 1. National review presentations on application purposes and research activities for thermal noise detection. (5 papers); 2. Detection instruments and electronic equipment for temperature measurements in fast reactors. (5 papers); 3. Physical models. (2 papers); 4. Signal processing techniques. (3 papers). A separate abstract was prepared for each of these papers

  7. Distance-based microfluidic quantitative detection methods for point-of-care testing.

    Science.gov (United States)

    Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James

    2016-04-07

    Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.

  8. A Chemoenzymatic Histology Method for O-GlcNAc Detection.

    Science.gov (United States)

    Aguilar, Aime Lopez; Hou, Xiaomeng; Wen, Liuqing; Wang, Peng G; Wu, Peng

    2017-12-14

    Modification of nuclear and cytoplasmic proteins by the addition or removal of O-GlcNAc dynamically impacts multiple biological processes. Here, we present the development of a chemoenzymatic histology method for the detection of O-GlcNAc in tissue specimens. We applied this method to screen murine organs, uncovering specific O-GlcNAc distribution patterns in different tissue structures. We then utilized our histology method for O-GlcNAc detection in human brain specimens from healthy donors and donors with Alzheimer's disease and found higher levels of O-GlcNAc in specimens from healthy donors. We also performed an analysis using a multiple cancer tissue array, uncovering different O-GlcNAc levels between healthy and cancerous tissues, as well as different O-GlcNAc cellular distributions within certain tissue specimens. This chemoenzymatic histology method therefore holds great potential for revealing the biology of O-GlcNAc in physiopathological processes. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Onset Detection in Surface Electromyographic Signals: A Systematic Comparison of Methods

    Directory of Open Access Journals (Sweden)

    Claus Flachenecker

    2001-06-01

    Full Text Available Various methods to determine the onset of the electromyographic activity which occurs in response to a stimulus have been discussed in the literature over the last decade. Due to the stochastic characteristic of the surface electromyogram (SEMG, onset detection is a challenging task, especially in weak SEMG responses. The performance of the onset detection methods were tested, mostly by comparing their automated onset estimations to the manually determined onsets found by well-trained SEMG examiners. But a systematic comparison between methods, which reveals the benefits and the drawbacks of each method compared to the other ones and shows the specific dependence of the detection accuracy on signal parameters, is still lacking. In this paper, several classical threshold-based approaches as well as some statistically optimized algorithms were tested on large samples of simulated SEMG data with well-known signal parameters. Rating between methods is performed by comparing their performance to that of a statistically optimal maximum likelihood estimator which serves as reference method. In addition, performance was evaluated on real SEMG data obtained in a reaction time experiment. Results indicate that detection behavior strongly depends on SEMG parameters, such as onset rise time, signal-to-noise ratio or background activity level. It is shown that some of the threshold-based signal-power-estimation procedures are very sensitive to signal parameters, whereas statistically optimized algorithms are generally more robust.

  10. PAUT-based defect detection method for submarine pressure hulls

    Directory of Open Access Journals (Sweden)

    Min-jae Jung

    2018-03-01

    Full Text Available A submarine has a pressure hull that can withstand high hydraulic pressure and therefore, requires the use of highly advanced shipbuilding technology. When producing a pressure hull, periodic inspection, repair, and maintenance are conducted to maintain its soundness. Of the maintenance methods, Non-Destructive Testing (NDT is the most effective, because it does not damage the target but sustains its original form and function while inspecting internal and external defects. The NDT process to detect defects in the welded parts of the submarine is applied through Magnetic particle Testing (MT to detect surface defects and Ultrasonic Testing (UT and Radiography Testing (RT to detect internal defects. In comparison with RT, UT encounters difficulties in distinguishing the types of defects, can yield different results depending on the skills of the inspector, and stores no inspection record. At the same time, the use of RT gives rise to issues related to worker safety due to radiation exposure. RT is also difficult to apply from the perspectives of the manufacturing of the submarine and economic feasibility. Therefore, in this study, the Phased Array Ultrasonic Testing (PAUT method was applied to propose an inspection method that can address the above disadvantages by designing a probe to enhance the precision of detection of hull defects and the reliability of calculations of defect size. Keywords: Submarine pressure hull, Non-destructive testing, Phased array ultrasonic testing

  11. Molecular techniques: An overview of methods for the detection of ...

    African Journals Online (AJOL)

    Several DNA molecular markers are now available for use in surveillance and investigation of food-borne outbreaks that were previously difficult to detect. The results from several sources of literature indicate substantially different degrees of sensitivities between conventional detection methods and molecular-based ...

  12. Annual meeting on nuclear technology 1980. Technical meeting: Early detection methods

    International Nuclear Information System (INIS)

    1980-01-01

    The practical methods refer to the neutron noise analysis of BWR-type reactors, the development and implementation of an early detection system for BWR-type reactors and the possibilities of the noise analysis in natrium-cooled fast breeder reactors. The mathematical methods are concerned with the stochastic analysis, high-frequency acoustic monitoring and early detection of damage in PWR-type reactors. (DG) [de

  13. A Hybrid Vehicle Detection Method Based on Viola-Jones and HOG + SVM from UAV Images

    Science.gov (United States)

    Xu, Yongzheng; Yu, Guizhen; Wang, Yunpeng; Wu, Xinkai; Ma, Yalong

    2016-01-01

    A new hybrid vehicle detection scheme which integrates the Viola-Jones (V-J) and linear SVM classifier with HOG feature (HOG + SVM) methods is proposed for vehicle detection from low-altitude unmanned aerial vehicle (UAV) images. As both V-J and HOG + SVM are sensitive to on-road vehicles’ in-plane rotation, the proposed scheme first adopts a roadway orientation adjustment method, which rotates each UAV image to align the roads with the horizontal direction so the original V-J or HOG + SVM method can be directly applied to achieve fast detection and high accuracy. To address the issue of descending detection speed for V-J and HOG + SVM, the proposed scheme further develops an adaptive switching strategy which sophistically integrates V-J and HOG + SVM methods based on their different descending trends of detection speed to improve detection efficiency. A comprehensive evaluation shows that the switching strategy, combined with the road orientation adjustment method, can significantly improve the efficiency and effectiveness of the vehicle detection from UAV images. The results also show that the proposed vehicle detection method is competitive compared with other existing vehicle detection methods. Furthermore, since the proposed vehicle detection method can be performed on videos captured from moving UAV platforms without the need of image registration or additional road database, it has great potentials of field applications. Future research will be focusing on expanding the current method for detecting other transportation modes such as buses, trucks, motors, bicycles, and pedestrians. PMID:27548179

  14. A Hybrid Vehicle Detection Method Based on Viola-Jones and HOG + SVM from UAV Images.

    Science.gov (United States)

    Xu, Yongzheng; Yu, Guizhen; Wang, Yunpeng; Wu, Xinkai; Ma, Yalong

    2016-08-19

    A new hybrid vehicle detection scheme which integrates the Viola-Jones (V-J) and linear SVM classifier with HOG feature (HOG + SVM) methods is proposed for vehicle detection from low-altitude unmanned aerial vehicle (UAV) images. As both V-J and HOG + SVM are sensitive to on-road vehicles' in-plane rotation, the proposed scheme first adopts a roadway orientation adjustment method, which rotates each UAV image to align the roads with the horizontal direction so the original V-J or HOG + SVM method can be directly applied to achieve fast detection and high accuracy. To address the issue of descending detection speed for V-J and HOG + SVM, the proposed scheme further develops an adaptive switching strategy which sophistically integrates V-J and HOG + SVM methods based on their different descending trends of detection speed to improve detection efficiency. A comprehensive evaluation shows that the switching strategy, combined with the road orientation adjustment method, can significantly improve the efficiency and effectiveness of the vehicle detection from UAV images. The results also show that the proposed vehicle detection method is competitive compared with other existing vehicle detection methods. Furthermore, since the proposed vehicle detection method can be performed on videos captured from moving UAV platforms without the need of image registration or additional road database, it has great potentials of field applications. Future research will be focusing on expanding the current method for detecting other transportation modes such as buses, trucks, motors, bicycles, and pedestrians.

  15. Effects of Feature Extraction and Classification Methods on Cyberbully Detection

    Directory of Open Access Journals (Sweden)

    Esra SARAÇ

    2016-12-01

    Full Text Available Cyberbullying is defined as an aggressive, intentional action against a defenseless person by using the Internet, or other electronic contents. Researchers have found that many of the bullying cases have tragically ended in suicides; hence automatic detection of cyberbullying has become important. In this study we show the effects of feature extraction, feature selection, and classification methods that are used, on the performance of automatic detection of cyberbullying. To perform the experiments FormSpring.me dataset is used and the effects of preprocessing methods; several classifiers like C4.5, Naïve Bayes, kNN, and SVM; and information gain and chi square feature selection methods are investigated. Experimental results indicate that the best classification results are obtained when alphabetic tokenization, no stemming, and no stopwords removal are applied. Using feature selection also improves cyberbully detection performance. When classifiers are compared, C4.5 performs the best for the used dataset.

  16. An intelligent detection method for high-field asymmetric waveform ion mobility spectrometry.

    Science.gov (United States)

    Li, Yue; Yu, Jianwen; Ruan, Zhiming; Chen, Chilai; Chen, Ran; Wang, Han; Liu, Youjiang; Wang, Xiaozhi; Li, Shan

    2018-04-01

    In conventional high-field asymmetric waveform ion mobility spectrometry signal acquisition, multi-cycle detection is time consuming and limits somewhat the technique's scope for rapid field detection. In this study, a novel intelligent detection approach has been developed in which a threshold was set on the relative error of α parameters, which can eliminate unnecessary time spent on detection. In this method, two full-spectrum scans were made in advance to obtain the estimated compensation voltage at different dispersion voltages, resulting in a narrowing down of the whole scan area to just the peak area(s) of interest. This intelligent detection method can reduce the detection time to 5-10% of that of the original full-spectrum scan in a single cycle.

  17. The Effect of Growing Rod Treatment on Hemoglobin and Hematocrit Levels in Early-onset Scoliosis.

    Science.gov (United States)

    Barrett, Kody K; Lee, Christopher; Myung, Karen; Johnston, Charles; Shah, Suken A; Akbarnia, Behrooz A; Skaggs, David L

    2016-09-01

    This study examines preoperative hemoglobin (Hgb) and hematocrit (Hct) levels in a group of early-onset scoliosis (EOS) patients and the effect of distraction-based growing rods (GRs) on these levels. Children with EOS are at risk for respiratory insufficiency and chronic hypoxemia. Increased Hgb and Hct levels have been identified as surrogate markers for chronic hypoxemia. A study of patients who underwent VEPTR surgery showed a significant decrease in Hgb levels following surgery. Data were retrospectively collected on 66 EOS patients without confounding respiratory issues or oxygen dependence who were treated with GRs at 5 institutions. Average age at initial surgery was 5.5 years. Patients were followed for a minimum of 2 years (average 3.7 y). Preoperative and postoperative Hgb and Hct levels were converted to Z-scores based on age-adjusted mean blood indices and were compared using a paired t test. The prevalence of elevated Hgb and Hct levels (Z-score >2) preoperatively was 15% (10/66) and 19% (12/64), respectively. The average Hgb Z-score decreased from 0.20 to -0.31 (P=0.005) 6 to 24 months following surgery and the Hct Z-score decreased from 0.31 to -0.28 (P=0.002) 6 to 24 months following surgery. Following distraction-based GR treatment of children with EOS there was a significant decrease in both their Hgb and Hct. This is a physiological marker of decreased hypoxemia and improved pulmonary function. Level III-therapeutic study.

  18. Hemoglobin and hematocrit levels in the prediction of complicated Crohn's disease behavior--a cohort study.

    Science.gov (United States)

    Rieder, Florian; Paul, Gisela; Schnoy, Elisabeth; Schleder, Stephan; Wolf, Alexandra; Kamm, Florian; Dirmeier, Andrea; Strauch, Ulrike; Obermeier, Florian; Lopez, Rocio; Achkar, Jean-Paul; Rogler, Gerhard; Klebl, Frank

    2014-01-01

    Markers that predict the occurrence of a complicated disease behavior in patients with Crohn's disease (CD) can permit a more aggressive therapeutic regimen for patients at risk. The aim of this cohort study was to test the blood levels of hemoglobin (Hgb) and hematocrit (Hct) for the prediction of complicated CD behavior and CD related surgery in an adult patient population. Blood samples of 62 CD patients of the German Inflammatory Bowel Disease-network "Kompetenznetz CED" were tested for the levels of Hgb and Hct prior to the occurrence of complicated disease behavior or CD related surgery. The relation of these markers and clinical events was studied using Kaplan-Meier survival analysis and adjusted COX-proportional hazard regression models. The median follow-up time was 55.8 months. Of the 62 CD patients without any previous complication or surgery 34% developed a complication and/or underwent CD related surgery. Low Hgb or Hct levels were independent predictors of a shorter time to occurrence of the first complication or CD related surgery. This was true for early as well as late occurring complications. Stable low Hgb or Hct during serial follow-up measurements had a higher frequency of complications compared to patients with a stable normal Hgb or Hct, respectively. Determination of Hgb or Hct in complication and surgery naïve CD patients might serve as an additional tool for the prediction of complicated disease behavior.

  19. A Markov blanket-based method for detecting causal SNPs in GWAS

    Directory of Open Access Journals (Sweden)

    Han Bing

    2010-04-01

    Full Text Available Abstract Background Detecting epistatic interactions associated with complex and common diseases can help to improve prevention, diagnosis and treatment of these diseases. With the development of genome-wide association studies (GWAS, designing powerful and robust computational method for identifying epistatic interactions associated with common diseases becomes a great challenge to bioinformatics society, because the study of epistatic interactions often deals with the large size of the genotyped data and the huge amount of combinations of all the possible genetic factors. Most existing computational detection methods are based on the classification capacity of SNP sets, which may fail to identify SNP sets that are strongly associated with the diseases and introduce a lot of false positives. In addition, most methods are not suitable for genome-wide scale studies due to their computational complexity. Results We propose a new Markov Blanket-based method, DASSO-MB (Detection of ASSOciations using Markov Blanket to detect epistatic interactions in case-control GWAS. Markov blanket of a target variable T can completely shield T from all other variables. Thus, we can guarantee that the SNP set detected by DASSO-MB has a strong association with diseases and contains fewest false positives. Furthermore, DASSO-MB uses a heuristic search strategy by calculating the association between variables to avoid the time-consuming training process as in other machine-learning methods. We apply our algorithm to simulated datasets and a real case-control dataset. We compare DASSO-MB to other commonly-used methods and show that our method significantly outperforms other methods and is capable of finding SNPs strongly associated with diseases. Conclusions Our study shows that DASSO-MB can identify a minimal set of causal SNPs associated with diseases, which contains less false positives compared to other existing methods. Given the huge size of genomic dataset

  20. Radioimmunoassay method for detection of gonorrhea antibodies

    International Nuclear Information System (INIS)

    1975-01-01

    A novel radioimmunoassay for the detection of gonorrhea antibodies in serum is described. A radionuclide is bound to gonorrhea antigens produced by a growth culture. In the presence of gonorrhea antibodies in the serum, an antigen-antibody conjugate is formed, the concentration of which can be measured with conventional radiometric methods. The radioimmunoassay is highly specific

  1. Tumor specific glycoproteins and method for detecting tumorigenic cancers

    International Nuclear Information System (INIS)

    Davidson, E.A.; Bolmer, S.D.

    1981-01-01

    The detection of tumour specific glycoproteins (TSGP) in human sera often indicates the presence of a malignant tumour in a patient. The distinguishing characteristics of TSGP isolated from the blood sera of cancer patients are described in detail together with methods of TSGP isolation and purification. Details are also given of radioimmunoassay techniques capable of detecting very low levels of serum TSGP with high specificity. (U.K.)

  2. Methods for the selective detection of alkyne-presenting molecules and related compositions and systems

    Science.gov (United States)

    Valdez, Carlos A.; Vu, Alexander K.

    2017-10-17

    Provided herein are methods for selectively detecting an alkyne-presenting molecule in a sample and related detection reagents, compositions, methods and systems. The methods include contacting a detection reagent with the sample for a time and under a condition to allow binding of the detection reagent to the one or more alkyne-presenting molecules possibly present in the matrix to the detection reagent. The detection reagent includes an organic label moiety presenting an azide group. The binding of the azide group to the alkyne-presenting molecules results in emission of a signal from the organic label moiety.

  3. Method for universal detection of two-photon polarization entanglement

    Science.gov (United States)

    Bartkiewicz, Karol; Horodecki, Paweł; Lemr, Karel; Miranowicz, Adam; Życzkowski, Karol

    2015-03-01

    Detecting and quantifying quantum entanglement of a given unknown state poses problems that are fundamentally important for quantum information processing. Surprisingly, no direct (i.e., without quantum tomography) universal experimental implementation of a necessary and sufficient test of entanglement has been designed even for a general two-qubit state. Here we propose an experimental method for detecting a collective universal witness, which is a necessary and sufficient test of two-photon polarization entanglement. It allows us to detect entanglement for any two-qubit mixed state and to establish tight upper and lower bounds on its amount. A different element of this method is the sequential character of its main components, which allows us to obtain relatively complicated information about quantum correlations with the help of simple linear-optical elements. As such, this proposal realizes a universal two-qubit entanglement test within the present state of the art of quantum optics. We show the optimality of our setup with respect to the minimal number of measured quantities.

  4. Thin layer chromatographic method for the detection of uric acid: collaborative study.

    Science.gov (United States)

    Thrasher, J J; Abadie, A

    1978-07-01

    A collaborative study has been completed on an improved method for the detection and confirmation of uric acid from bird and insect excreta. The proposed method involves the lithium carbonate solubilization of the suspect excreta material, followed by butanol-methanol-water-acetic acid thin layer chromatography, and trisodium phosphate-phosphotungstic acid color development. The collaborative tests resulted in 100% detection of uric acid standard at the 50 ng level and 75% detection at the 20-25 ng level. No false positives were reported during tests of compounds similar to uric acid. The proposed method has been adopted official first action; the present official final action method, 44.161, will be retained for screening purposes.

  5. Crack luminescence as an innovative method for detection of fatigue damage

    Directory of Open Access Journals (Sweden)

    R. Makris

    2018-04-01

    Full Text Available Conventional non-destructive testing methods for crack detection provide just a snapshot of fatigue crack evolution at a specific location in the moment of examination. The crack luminescence coating realizes a clear visibility of the entire crack formation. The coating consists of two layers with different properties and functions. The bottom layer emits light as fluorescence under UV radiation. The top layer covers the fluorescing one and prevents the emitting of light in case of no damage at the surface. Several different experiments show that due to the sensitive coating even the early stage of crack formation can be detected. That makes crack luminescence helpful for investigating the incipient crack opening behavior. Cracks can be detected and observed during operation of a structure, making it also very interesting for continuous monitoring. Crack luminescence is a passive method and no skilled professionals are necessary to detect cracks, as for conventional methods. The luminescent light is clearly noticeable by unaided eye observations and also by standard camera equipment, which makes automated crack detection possible as well. It is expected that crack luminescence can reduce costs and time for preventive maintenance and inspection.

  6. Proposed Sandia frequency shift for anti-islanding detection method based on artificial immune system

    Directory of Open Access Journals (Sweden)

    A.Y. Hatata

    2018-03-01

    Full Text Available Sandia frequency shift (SFS is one of the active anti-islanding detection methods that depend on frequency drift to detect an islanding condition for inverter-based distributed generation. The non-detection zone (NDZ of the SFS method depends to a great extent on its parameters. Improper adjusting of these parameters may result in failure of the method. This paper presents a proposed artificial immune system (AIS-based technique to obtain optimal parameters of SFS anti-islanding detection method. The immune system is highly distributed, highly adaptive, and self-organizing in nature, maintains a memory of past encounters, and has the ability to continually learn about new encounters. The proposed method generates less total harmonic distortion (THD than the conventional SFS, which results in faster island detection and better non-detection zone. The performance of the proposed method is derived analytically and simulated using Matlab/Simulink. Two case studies are used to verify the proposed method. The first case includes a photovoltaic (PV connected to grid and the second includes a wind turbine connected to grid. The deduced optimized parameter setting helps to achieve the “non-islanding inverter” as well as least potential adverse impact on power quality. Keywords: Anti-islanding detection, Sandia frequency shift (SFS, Non-detection zone (NDZ, Total harmonic distortion (THD, Artificial immune system (AIS, Clonal selection algorithm

  7. Balancing precision and risk: should multiple detection methods be analyzed separately in N-mixture models?

    Directory of Open Access Journals (Sweden)

    Tabitha A Graves

    Full Text Available Using multiple detection methods can increase the number, kind, and distribution of individuals sampled, which may increase accuracy and precision and reduce cost of population abundance estimates. However, when variables influencing abundance are of interest, if individuals detected via different methods are influenced by the landscape differently, separate analysis of multiple detection methods may be more appropriate. We evaluated the effects of combining two detection methods on the identification of variables important to local abundance using detections of grizzly bears with hair traps (systematic and bear rubs (opportunistic. We used hierarchical abundance models (N-mixture models with separate model components for each detection method. If both methods sample the same population, the use of either data set alone should (1 lead to the selection of the same variables as important and (2 provide similar estimates of relative local abundance. We hypothesized that the inclusion of 2 detection methods versus either method alone should (3 yield more support for variables identified in single method analyses (i.e. fewer variables and models with greater weight, and (4 improve precision of covariate estimates for variables selected in both separate and combined analyses because sample size is larger. As expected, joint analysis of both methods increased precision as well as certainty in variable and model selection. However, the single-method analyses identified different variables and the resulting predicted abundances had different spatial distributions. We recommend comparing single-method and jointly modeled results to identify the presence of individual heterogeneity between detection methods in N-mixture models, along with consideration of detection probabilities, correlations among variables, and tolerance to risk of failing to identify variables important to a subset of the population. The benefits of increased precision should be weighed

  8. Unsupervised detection of salt marsh platforms: a topographic method

    Science.gov (United States)

    Goodwin, Guillaume C. H.; Mudd, Simon M.; Clubb, Fiona J.

    2018-03-01

    Salt marshes filter pollutants, protect coastlines against storm surges, and sequester carbon, yet are under threat from sea level rise and anthropogenic modification. The sustained existence of the salt marsh ecosystem depends on the topographic evolution of marsh platforms. Quantifying marsh platform topography is vital for improving the management of these valuable landscapes. The determination of platform boundaries currently relies on supervised classification methods requiring near-infrared data to detect vegetation, or demands labour-intensive field surveys and digitisation. We propose a novel, unsupervised method to reproducibly isolate salt marsh scarps and platforms from a digital elevation model (DEM), referred to as Topographic Identification of Platforms (TIP). Field observations and numerical models show that salt marshes mature into subhorizontal platforms delineated by subvertical scarps. Based on this premise, we identify scarps as lines of local maxima on a slope raster, then fill landmasses from the scarps upward, thus isolating mature marsh platforms. We test the TIP method using lidar-derived DEMs from six salt marshes in England with varying tidal ranges and geometries, for which topographic platforms were manually isolated from tidal flats. Agreement between manual and unsupervised classification exceeds 94 % for DEM resolutions of 1 m, with all but one site maintaining an accuracy superior to 90 % for resolutions up to 3 m. For resolutions of 1 m, platforms detected with the TIP method are comparable in surface area to digitised platforms and have similar elevation distributions. We also find that our method allows for the accurate detection of local block failures as small as 3 times the DEM resolution. Detailed inspection reveals that although tidal creeks were digitised as part of the marsh platform, unsupervised classification categorises them as part of the tidal flat, causing an increase in false negatives and overall platform

  9. Unsupervised detection of salt marsh platforms: a topographic method

    Directory of Open Access Journals (Sweden)

    G. C. H. Goodwin

    2018-03-01

    Full Text Available Salt marshes filter pollutants, protect coastlines against storm surges, and sequester carbon, yet are under threat from sea level rise and anthropogenic modification. The sustained existence of the salt marsh ecosystem depends on the topographic evolution of marsh platforms. Quantifying marsh platform topography is vital for improving the management of these valuable landscapes. The determination of platform boundaries currently relies on supervised classification methods requiring near-infrared data to detect vegetation, or demands labour-intensive field surveys and digitisation. We propose a novel, unsupervised method to reproducibly isolate salt marsh scarps and platforms from a digital elevation model (DEM, referred to as Topographic Identification of Platforms (TIP. Field observations and numerical models show that salt marshes mature into subhorizontal platforms delineated by subvertical scarps. Based on this premise, we identify scarps as lines of local maxima on a slope raster, then fill landmasses from the scarps upward, thus isolating mature marsh platforms. We test the TIP method using lidar-derived DEMs from six salt marshes in England with varying tidal ranges and geometries, for which topographic platforms were manually isolated from tidal flats. Agreement between manual and unsupervised classification exceeds 94 % for DEM resolutions of 1 m, with all but one site maintaining an accuracy superior to 90 % for resolutions up to 3 m. For resolutions of 1 m, platforms detected with the TIP method are comparable in surface area to digitised platforms and have similar elevation distributions. We also find that our method allows for the accurate detection of local block failures as small as 3 times the DEM resolution. Detailed inspection reveals that although tidal creeks were digitised as part of the marsh platform, unsupervised classification categorises them as part of the tidal flat, causing an increase in false negatives

  10. Safety assessment and detection methods of genetically modified organisms.

    Science.gov (United States)

    Xu, Rong; Zheng, Zhe; Jiao, Guanglian

    2014-01-01

    Genetically modified organisms (GMOs), are gaining importance in agriculture as well as the production of food and feed. Along with the development of GMOs, health and food safety concerns have been raised. These concerns for these new GMOs make it necessary to set up strict system on food safety assessment of GMOs. The food safety assessment of GMOs, current development status of safety and precise transgenic technologies and GMOs detection have been discussed in this review. The recent patents about GMOs and their detection methods are also reviewed. This review can provide elementary introduction on how to assess and detect GMOs.

  11. A fast button surface defects detection method based on convolutional neural network

    Science.gov (United States)

    Liu, Lizhe; Cao, Danhua; Wu, Songlin; Wu, Yubin; Wei, Taoran

    2018-01-01

    Considering the complexity of the button surface texture and the variety of buttons and defects, we propose a fast visual method for button surface defect detection, based on convolutional neural network (CNN). CNN has the ability to extract the essential features by training, avoiding designing complex feature operators adapted to different kinds of buttons, textures and defects. Firstly, we obtain the normalized button region and then use HOG-SVM method to identify the front and back side of the button. Finally, a convolutional neural network is developed to recognize the defects. Aiming at detecting the subtle defects, we propose a network structure with multiple feature channels input. To deal with the defects of different scales, we take a strategy of multi-scale image block detection. The experimental results show that our method is valid for a variety of buttons and able to recognize all kinds of defects that have occurred, including dent, crack, stain, hole, wrong paint and uneven. The detection rate exceeds 96%, which is much better than traditional methods based on SVM and methods based on template match. Our method can reach the speed of 5 fps on DSP based smart camera with 600 MHz frequency.

  12. Doppler Radar Vital Signs Detection Method Based on Higher Order Cyclostationary.

    Science.gov (United States)

    Yu, Zhibin; Zhao, Duo; Zhang, Zhiqiang

    2017-12-26

    Due to the non-contact nature, using Doppler radar sensors to detect vital signs such as heart and respiration rates of a human subject is getting more and more attention. However, the related detection-method research meets lots of challenges due to electromagnetic interferences, clutter and random motion interferences. In this paper, a novel third-order cyclic cummulant (TOCC) detection method, which is insensitive to Gaussian interference and non-cyclic signals, is proposed to investigate the heart and respiration rate based on continuous wave Doppler radars. The k -th order cyclostationary properties of the radar signal with hidden periodicities and random motions are analyzed. The third-order cyclostationary detection theory of the heart and respiration rate is studied. Experimental results show that the third-order cyclostationary approach has better estimation accuracy for detecting the vital signs from the received radar signal under low SNR, strong clutter noise and random motion interferences.

  13. A whole-mount in situ hybridization method for microRNA detection in Caenorhabditis elegans.

    Science.gov (United States)

    Andachi, Yoshiki; Kohara, Yuji

    2016-07-01

    Whole-mount in situ hybridization (WISH) is an outstanding method to decipher the spatiotemporal expression patterns of microRNAs (miRNAs) and provides important clues for elucidating their functions. The first WISH method for miRNA detection was developed in zebrafish. Although this method was quickly adapted for other vertebrates and fruit flies, WISH analysis has not been successfully used to detect miRNAs in Caenorhabditis elegans Here, we show a novel WISH method for miRNA detection in C. elegans Using this method, mir-1 miRNA was detected in the body-wall muscle where the expression and roles of mir-1 miRNA have been previously elucidated. Application of the method to let-7 family miRNAs, let-7, mir-48, mir-84, and mir-241, revealed their distinct but partially overlapping expression patterns, indicating that miRNAs sharing a short common sequence were distinguishably detected. In pash-1 mutants that were depleted of mature miRNAs, signals of mir-48 miRNA were greatly reduced, suggesting that mature miRNAs were detected by the method. These results demonstrate the validity of WISH to detect mature miRNAs in C. elegans. © 2016 Andachi and Kohara; Published by Cold Spring Harbor Laboratory Press for the RNA Society.

  14. Study on detection method of irradiated frozen foods and others

    International Nuclear Information System (INIS)

    Miyahara, Makoto; Toyoda, Masatake; Saito, Yukio

    1997-01-01

    As detection method of the irradiated foods has history of 20 years, it is said that it has no finished chemical method, which is longed to construct as soon as possible. Up-to-date, many kinds of chemical detection methods have been proposed, the o-tyrosine method thought to be hopeful for the irradiated frozen foods among them was selected to investigate. In this method, phenyl alanine is oxidized with a radical formed on irradiation to tyrosine. The o-tyrosine out of the formed isomers is analyzed quantitatively. When irradiation γ-ray to foods, it was found that amounts of o-tyrosine increased to reach about 2 or 3 times of original amounts. This result was also found to agree with the result reported at the ADMIT conference. Furthermore, possibility of judgement using this method was also shown because of difference on 2 or 3 times of o-tyrosine amounts between unirradiated and over 5 kGy irradiated foods. (G.K.)

  15. Performance evaluation of sea surface simulation methods for target detection

    Science.gov (United States)

    Xia, Renjie; Wu, Xin; Yang, Chen; Han, Yiping; Zhang, Jianqi

    2017-11-01

    With the fast development of sea surface target detection by optoelectronic sensors, machine learning has been adopted to improve the detection performance. Many features can be learned from training images by machines automatically. However, field images of sea surface target are not sufficient as training data. 3D scene simulation is a promising method to address this problem. For ocean scene simulation, sea surface height field generation is the key point to achieve high fidelity. In this paper, two spectra-based height field generation methods are evaluated. Comparison between the linear superposition and linear filter method is made quantitatively with a statistical model. 3D ocean scene simulating results show the different features between the methods, which can give reference for synthesizing sea surface target images with different ocean conditions.

  16. Development of detection methods for irradiated foods - Development of detection method for radiolytic products of irradiated foods

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyong Su; Lee, Eun Ryong; Hong, Hae Jung [Chosun University, Kwangju (Korea)

    2000-07-01

    Meats, nuts, legumes and cereals were irradiated with {sup 60}Co {gamma}-ray. The detection methods included the fat extraction from samples, isolation of hydrocarbons and 2-alkylcyclobutanones by florisil column chromatography and analyses of GC-FID and GC/MS analyzers. Concentrations of hydrocarbons and 2-clobutanones increased with the irradiation dose in meat, nuts, legumes and cereals. In nuts (sesame seeds, black sesame seeds, perilla seeds, pine nuts and peanuts), legumes (white beans, black soybeans, yellow bean sprout soybeans, mouse-eyed soybeans, mung beans, kidney beans and small red beans) and cereals (brown rice, corns and wheat), 8-heptadecene and 1,7-hexadecadiene originated from oleic acid and 6,9-heptadecadiene and 1,7,10-hexadecatriene induced from linoleic acids were the major hydrocarbons due to the composition of fatty acids. Concentrations of radiation-induced hydrocarbons in nuts were slightly reduced and hydrocarbons were still significantly detectable, during 6 months at -18 deg. C. In meats and nuts, 2-(5'-tetradecenyl)cyclobutanone formed from oleic acid was found in most. 2-Dodecylcyclobutanone was detected in a large amount. The concentrations of radiation-induced 2-alkylcyclobutanones in meats slightly decreased, but relatively constant during 6 months at -18 deg. C. 62 refs., 45 figs., 25 tabs. (Author)

  17. Immunochemical method for quantitative evaluation of vasogenic brain edema following cold injury of rat brain

    Energy Technology Data Exchange (ETDEWEB)

    Bodsch, W; Huerter, T; Hossmann, K A [Max-Planck-Institut fuer Hirnforschung, Koeln (Germany, F.R.). Forschungsstelle fuer Hirnkreislauf-Forschung

    1982-10-07

    An immunochemical method is described for quantitative assessment of serum proteins and hemoglobin content in brain tissue homogenates. Using a combination of affinity chromatography and radioimmunoassay, the sensitivity of the method is 50 ng hemoglobin and 100 ng serum protein per assay, respectively. The method was used to measure cerebral hematocrit, blood volume and serum protein extravasation in rat brain at various times following cold injury. In control rats cerebral blood volume was 6.88 +- 0.15 ml/100 g and cerebral hematocrit 26.4 +- 0.86% (means +- S.E.). Following cold injury blood volume did not significantly change, but there was a gradual increase of extravasated serum proteins, reaching a maximum of 21.54 +- 2.76 mg/g d.w. after 8 hours. Thereafter protein content gradually declined, but even after 64 h it was distinctly increased. Protein extravasation was partly dissociated from the increase of brain water and sodium which reached a maximum already after 2 h and which normalized within 32 and 64 h, respectively. It is concluded that edema fluid associated with cold injury is not simply an ultrafiltrate of blood serum but consists of cytotoxic and vasogenic components which follow a different time course both during formation and resolution of edema.

  18. Immunochemical method for quantitative evaluation of vasogenic brain edema following cold injury of rat brain

    International Nuclear Information System (INIS)

    Bodsch, W.; Huerter, T.; Hossmann, K.-A.

    1982-01-01

    An immunochemical method is described for quantitative assessment of serum proteins and hemoglobin content in brain tissue homogenates. Using a combination of affinity chromatography and radioimmunoassay, the sensitivity of the method is 50 ng hemoglobin and 100 ng serum protein per assay, respectively. The method was used to measure cerebral hematocrit, blood volume and serum protein extravasation in rat brain at various times following cold injury. In control rats cerebral blood volume was 6.88 +- 0.15 ml/100 g and cerebral hematocrit 26.4 +- 0.86% (means +- S.E.). Following cold injury blood volume did not significantly change, but there was a gradual increase of extravasated serum proteins, reaching a maximum of 21.54 +- 2.76 mg/g d.w. after 8 hours. Thereafter protein content gradually declined, but even after 64 h it was distinctly increased. Protein extravasation was partly dissociated from the increase of brain water and sodium which reached a maximum already after 2 h and which normalized within 32 and 64 h, respectively. It is concluded that edema fluid associated with cold injury is not simply an ultrafiltrate of blood serum but consists of cytotoxic and vasogenic components which follow a different time course both during formation and resolution of edema. (Auth.)

  19. DNA based methods used for characterization and detection of food ...

    African Journals Online (AJOL)

    Detection of food borne pathogen is of outmost importance in the food industries and related agencies. For the last few decades conventional methods were used to detect food borne pathogens based on phenotypic characters. At the advent of complementary base pairing and amplification of DNA, the diagnosis of food ...

  20. Detection of Babesia caballi and Theileria equi in Blood from Equines from Four Indigenous Communities in Costa Rica

    Directory of Open Access Journals (Sweden)

    María Fernanda Posada-Guzmán

    2015-01-01

    Full Text Available A cross-sectional study was carried out in four indigenous communities of Costa Rica to detect presence and prevalence of Babesia caballi and Theileria equi and to investigate factors associated with presence of these hemoparasites. General condition of horses (n=285 was evaluated, and hematocrits and hemoglobin were determined from blood samples of 130 horses, which were also analyzed using blood smears, nested polymerase chain reaction (PCR, and immunosorbent assay (c-ELISA. The general condition of the horses (n=285 in terms of their body and coat was between regular and poor, and hematocrit and hemoglobin average values were low (19% and 10.65 g/dL, resp.. Erythrocyte inclusions were observed in 32 (24.6% of the samples. Twenty-six samples (20.0% gave positive results for B. caballi and 60 (46.2% for T. equi; 10 horses (7.7% showed mixed infection, when analyzed by PCR. Using c-ELISA, it was found that 90 (69.2% horses had antibodies against B. caballi and 115 (88.5% against T. equi, while 81 (62.3% showed mixed reactions. There were no factors associated with the presence of B. caballi and T. equi. These results contrast with results previously obtained in equines in the Central Valley of Costa Rica.

  1. Detection of Babesia caballi and Theileria equi in Blood from Equines from Four Indigenous Communities in Costa Rica.

    Science.gov (United States)

    Posada-Guzmán, María Fernanda; Dolz, Gaby; Romero-Zúñiga, Juan José; Jiménez-Rocha, Ana Eugenia

    2015-01-01

    A cross-sectional study was carried out in four indigenous communities of Costa Rica to detect presence and prevalence of Babesia caballi and Theileria equi and to investigate factors associated with presence of these hemoparasites. General condition of horses (n = 285) was evaluated, and hematocrits and hemoglobin were determined from blood samples of 130 horses, which were also analyzed using blood smears, nested polymerase chain reaction (PCR), and immunosorbent assay (c-ELISA). The general condition of the horses (n = 285) in terms of their body and coat was between regular and poor, and hematocrit and hemoglobin average values were low (19% and 10.65 g/dL, resp.). Erythrocyte inclusions were observed in 32 (24.6%) of the samples. Twenty-six samples (20.0%) gave positive results for B. caballi and 60 (46.2%) for T. equi; 10 horses (7.7%) showed mixed infection, when analyzed by PCR. Using c-ELISA, it was found that 90 (69.2%) horses had antibodies against B. caballi and 115 (88.5%) against T. equi, while 81 (62.3%) showed mixed reactions. There were no factors associated with the presence of B. caballi and T. equi. These results contrast with results previously obtained in equines in the Central Valley of Costa Rica.

  2. Improving Distributed Denial of Service (DDOS Detection using Entropy Method in Software Defined Network (SDN

    Directory of Open Access Journals (Sweden)

    Maman Abdurohman

    2017-12-01

    Full Text Available This research proposed a new method to enhance Distributed Denial of Service (DDoS detection attack on Software Defined Network (SDN environment. This research utilized the OpenFlow controller of SDN for DDoS attack detection using modified method and regarding entropy value. The new method would check whether the traffic was a normal traffic or DDoS attack by measuring the randomness of the packets. This method consisted of two steps, detecting attack and checking the entropy. The result shows that the new method can reduce false positive when there is a temporary and sudden increase in normal traffic. The new method succeeds in not detecting this as a DDoS attack. Compared to previous methods, this proposed method can enhance DDoS attack detection on SDN environment.

  3. Systems and Methods for Automated Water Detection Using Visible Sensors

    Science.gov (United States)

    Rankin, Arturo L. (Inventor); Matthies, Larry H. (Inventor); Bellutta, Paolo (Inventor)

    2016-01-01

    Systems and methods are disclosed that include automated machine vision that can utilize images of scenes captured by a 3D imaging system configured to image light within the visible light spectrum to detect water. One embodiment includes autonomously detecting water bodies within a scene including capturing at least one 3D image of a scene using a sensor system configured to detect visible light and to measure distance from points within the scene to the sensor system, and detecting water within the scene using a processor configured to detect regions within each of the at least one 3D images that possess at least one characteristic indicative of the presence of water.

  4. R Peak Detection Method Using Wavelet Transform and Modified Shannon Energy Envelope.

    Science.gov (United States)

    Park, Jeong-Seon; Lee, Sang-Woong; Park, Unsang

    2017-01-01

    Rapid automatic detection of the fiducial points-namely, the P wave, QRS complex, and T wave-is necessary for early detection of cardiovascular diseases (CVDs). In this paper, we present an R peak detection method using the wavelet transform (WT) and a modified Shannon energy envelope (SEE) for rapid ECG analysis. The proposed WTSEE algorithm performs a wavelet transform to reduce the size and noise of ECG signals and creates SEE after first-order differentiation and amplitude normalization. Subsequently, the peak energy envelope (PEE) is extracted from the SEE. Then, R peaks are estimated from the PEE, and the estimated peaks are adjusted from the input ECG. Finally, the algorithm generates the final R features by validating R-R intervals and updating the extracted R peaks. The proposed R peak detection method was validated using 48 first-channel ECG records of the MIT-BIH arrhythmia database with a sensitivity of 99.93%, positive predictability of 99.91%, detection error rate of 0.16%, and accuracy of 99.84%. Considering the high detection accuracy and fast processing speed due to the wavelet transform applied before calculating SEE, the proposed method is highly effective for real-time applications in early detection of CVDs.

  5. The Detection Method of Escherichia coli in Water Resources: A Review

    Science.gov (United States)

    Nurliyana, M. R.; Sahdan, M. Z.; Wibowo, K. M.; Muslihati, A.; Saim, H.; Ahmad, S. A.; Sari, Y.; Mansor, Z.

    2018-04-01

    This article reviews several approaches for Escherichia coli (E. coli) bacteria detection from conventional methods, emerging method and goes to biosensor-based techniques. Detection and enumeration of E. coli bacteria usually required long duration of time in obtaining the result since laboratory-based approach is normally used in its assessment. It requires 24 hours to 72 hours after sampling to process the culturing samples before results are available. Although faster technique for detecting E. coli in water such as Polymerase Chain Reaction (PCR) and Enzyme-Linked Immunosorbent Assay (ELISA) have been developed, it still required transporting the samples from water resources to the laboratory, high-cost, complicated equipment usage, complex procedures, as well as the requirement of skilled specialist to cope with the complexity which limit their wide spread practice in water quality detection. Recently, development of biosensor device that is easy to perform, portable, highly sensitive and selective becomes indispensable in detecting extremely lower consolidation of pathogenic E. coli bacteria in water samples.

  6. Methods of detecting tritium in gases and liquids

    Energy Technology Data Exchange (ETDEWEB)

    Petr, I

    1977-07-01

    Tritium mainly occurs in gases in two chemical forms, i.e., as water vapour (HTO) or elemental hydrogen (HT). Two methods for tritium gas measuring are described. The first consists in the use of an ionization chamber or a proportional counter with the sample sucked in through a filter to the detector working volume. The second consists in the separation of tritium (in the form of HTO) from the gas sample by sorption on silica gel or on molecular sieves and its detection using a liquid or a plastic scintillation detector. Tritium in the form of HT and gaseous organic tritium compounds are determined using the same measuring method after oxidation of the gaseous samples to HTO by burning. A description is given of detectors and measuring methods. Tritium in liquids mainly occurs in the form of tritiated water (HTO). The most commonly used method of tritium detection in liquids is the application of liquid scintillation detectors in which the sample is dissolved or suspended and measured with two photomultipliers in time-coincidence connection. The main advantage of liquid scintillators is the possibility to achieve the 4..pi.. measurement geometry. The methods of calibration and of checking the stability of a measuring system with liquid scintillators are described as are the applications of plastic scintillators in measuring tritium in liquids. Plastic scintillators are less costly in operation and show a more rapid response but their sensitivity is lower. The threshold values of activity are shown in dependence on the detector applied, the chemical form of tritium and the sampling method.

  7. A current detection based on an extension of the Prony's method

    Energy Technology Data Exchange (ETDEWEB)

    Deng, C.; Xia, X.; Gong, F. [Changsha Univ. of Science and Technology, Changsha (China). College of Electrical Engineering

    2009-07-01

    The Prony method for spectrum estimation was combined with an adaptive frequency tracking and current frequency demultiplication method as a harmonic detection system. An injective active power filter was used for effective harmonic wave management. The automated system includes a digital signal processor and a high-speed interfacing device. An algorithm was developed to consider the slow voltage changes in the power grid as well as potential mutations in current harmonics. Widrow-Hoff's LMS algorithm was used to develop rolling steps for the filter. The method was used to detect harmonic waves with a sampling frequency of 400 Hz. Results of the study showed that the detection method can be used in real time to detect fundamental and first harmonics in electric power grids. 10 refs., 2 tabs., 1 fig.

  8. A Prognostic Method for Fault Detection in Wind Turbine Drivetrains

    DEFF Research Database (Denmark)

    Nejada, Amir R.; Odgaard, Peter Fogh; Gao, Zhen

    2014-01-01

    In this paper, a prognostic method is presented for fault detection in gears and bearings in wind turbine drivetrains. This method is based on angular velocity measurements from the gearbox input shaft and the output to the generator, using two additional angular velocity sensors on the intermedi......In this paper, a prognostic method is presented for fault detection in gears and bearings in wind turbine drivetrains. This method is based on angular velocity measurements from the gearbox input shaft and the output to the generator, using two additional angular velocity sensors...... bearing faults in three locations: the high-speed shaft stage, the planetary stage and the intermediate-speed shaft stage. Simulations of the faulty and fault-free cases are performed on a gearbox model implemented in multibody dynamic simulation software. The global loads on the gearbox are obtained from...

  9. QUALITATIVE ANALYSIS METHOD OF DETECTION OF WAX CONTENT IN GORENGAN USING SMARTPHONE

    Directory of Open Access Journals (Sweden)

    Yulia Yulia

    2018-05-01

    Full Text Available Wax is one of the compounds that can be misused to be added to Gorengan, Indonesian fritter, to keep them crispy. Gorengan containing wax is difficult to identify visually, so a quick and easy method of detecting wax content is required. The purpose of this research is to develop and evaluate the analytical performance of detecting wax content in gorengan using smartphone. Gorengan sample was dissolved with hexane and then added reagent that will give discoloration followed by analysis using smartphone. Some analysis performance parameters were evaluated in terms of linearity and detection limit, qualitative analysis capability, precision, and selectivity test. The developed method was also applied in some gorengan samples. The result shows that the detection of wax content in gorengan can be conducted by using reagent consisting of NaOH, Schift, and curcumin (1 : 2 : 2. Performance analysis shows that the linearity measurement at concentration between 10% and 25% has correlation coefficient (r of 0.9537 with detection limit at concentration of 2% and precision (%RSD less than 3%. The developed method can be applied for the detection of wax content in gorengan in the market.

  10. Molecular Methods for the Detection of Mycoplasma and Ureaplasma Infections in Humans

    Science.gov (United States)

    Waites, Ken B.; Xiao, Li; Paralanov, Vanya; Viscardi, Rose M.; Glass, John I.

    2012-01-01

    Mycoplasma and Ureaplasma species are well-known human pathogens responsible for a broad array of inflammatory conditions involving the respiratory and urogenital tracts of neonates, children, and adults. Greater attention is being given to these organisms in diagnostic microbiology, largely as a result of improved methods for their laboratory detection, made possible by powerful molecular-based techniques that can be used for primary detection in clinical specimens. For slow-growing species, such as Mycoplasma pneumoniae and Mycoplasma genitalium, molecular-based detection is the only practical means for rapid microbiological diagnosis. Most molecular-based methods used for detection and characterization of conventional bacteria have been applied to these organisms. A complete genome sequence is available for one or more strains of all of the important human pathogens in the Mycoplasma and Ureaplasma genera. Information gained from genome analyses and improvements in efficiency of DNA sequencing are expected to significantly advance the field of molecular detection and genotyping during the next few years. This review provides a summary and critical review of methods suitable for detection and characterization of mycoplasmas and ureaplasmas of humans, with emphasis on molecular genotypic techniques. PMID:22819362

  11. Are adequate methods available to detect protist parasites on fresh produce?

    Science.gov (United States)

    Human parasitic protists such as Cryptosporidium, Giardia and microsporidia contaminate a variety of fresh produce worldwide. Existing detection methods lack sensitivity and specificity for most foodborne parasites. Furthermore, detection has been problematic because these parasites adhere tenacious...

  12. Neutron imaging integrated circuit and method for detecting neutrons

    Science.gov (United States)

    Nagarkar, Vivek V.; More, Mitali J.

    2017-12-05

    The present disclosure provides a neutron imaging detector and a method for detecting neutrons. In one example, a method includes providing a neutron imaging detector including plurality of memory cells and a conversion layer on the memory cells, setting one or more of the memory cells to a first charge state, positioning the neutron imaging detector in a neutron environment for a predetermined time period, and reading a state change at one of the memory cells, and measuring a charge state change at one of the plurality of memory cells from the first charge state to a second charge state less than the first charge state, where the charge state change indicates detection of neutrons at said one of the memory cells.

  13. Real-time biscuit tile image segmentation method based on edge detection.

    Science.gov (United States)

    Matić, Tomislav; Aleksi, Ivan; Hocenski, Željko; Kraus, Dieter

    2018-05-01

    In this paper we propose a novel real-time Biscuit Tile Segmentation (BTS) method for images from ceramic tile production line. BTS method is based on signal change detection and contour tracing with a main goal of separating tile pixels from background in images captured on the production line. Usually, human operators are visually inspecting and classifying produced ceramic tiles. Computer vision and image processing techniques can automate visual inspection process if they fulfill real-time requirements. Important step in this process is a real-time tile pixels segmentation. BTS method is implemented for parallel execution on a GPU device to satisfy the real-time constraints of tile production line. BTS method outperforms 2D threshold-based methods, 1D edge detection methods and contour-based methods. Proposed BTS method is in use in the biscuit tile production line. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  14. Evaluation and performance analysis of hydrocarbon detection methods using hyperspectral data

    OpenAIRE

    Lenz, Andreas; Schilling, Hendrik; Gross, Wolfgang; Middelmann, Wolfgang

    2015-01-01

    Different methods for the detection for hydrocarbons in aerial hyperspectral images are analyzed in this study. The scope is to find a practical method for airborne oil spill mapping on land. Examined are Hydrocarbon index and Hydrocarbon detection index. As well as spectral reidentification algorithms, like Spectral angle mapper, in comparison to the indices. The influence of different ground coverage and different hydrocarbons was tested and evaluated. A ground measurement campaign was cond...

  15. LEA Detection and Tracking Method for Color-Independent Visual-MIMO

    Directory of Open Access Journals (Sweden)

    Jai-Eun Kim

    2016-07-01

    Full Text Available Communication performance in the color-independent visual-multiple input multiple output (visual-MIMO technique is deteriorated by light emitting array (LEA detection and tracking errors in the received image because the image sensor included in the camera must be used as the receiver in the visual-MIMO system. In this paper, in order to improve detection reliability, we first set up the color-space-based region of interest (ROI in which an LEA is likely to be placed, and then use the Harris corner detection method. Next, we use Kalman filtering for robust tracking by predicting the most probable location of the LEA when the relative position between the camera and the LEA varies. In the last step of our proposed method, the perspective projection is used to correct the distorted image, which can improve the symbol decision accuracy. Finally, through numerical simulation, we show the possibility of robust detection and tracking of the LEA, which results in a symbol error rate (SER performance improvement.

  16. A rapid detection method for policy-sensitive amines real-time supervision.

    Science.gov (United States)

    Zhang, Haixu; Shu, Jinian; Yang, Bo; Zhang, Peng; Ma, Pengkun

    2018-02-01

    Many organic amines that comprise a benzene ring are policy-sensitive because of their toxicity and links to social harm. However, to date, detection of such compounds mainly relies on offline methods. This study proposes an online pptv (parts per trillion by volume) level of detection method for amines, using the recently-built vacuum ultraviolet photoionization mass spectrometer (VUV-PIMS) combined with a new doping technique. Thus, the dichloromethane doping-assisted photoionization mass spectra of aniline, benzylamine, phenethylamine, amphetamine, and their structural isomers were recorded. The dominant characteristic mass peaks for all amines are those afforded by protonated amines and the amino radical-loss. The signal intensities of the amines were enhanced by 60-130 times compared to those recorded without doping assistance. Under 10s detection time, the sensitivities of aniline and benzylamine in the gas phase were determined as 4.0 and 2.7 countspptv -1 , with limits of detection (LODs) of 36 and 22 pptv, respectively. Notably, the detection efficiency of this method can be tenfold better in future applications since the ion transmission efficiency of the mass spectrometer was intentionally reduced to ~ 10% in this study. Therefore, dichloromethane doping-assisted photoionization mass spectrometry has proven to be a highly promising on-line approach to amine detection in environmental and judicial supervision and shows great potential for application in the biological field. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Detection and monitoring of invasive exotic plants: a comparison of four sampling methods

    Science.gov (United States)

    Cynthia D. Huebner

    2007-01-01

    The ability to detect and monitor exotic invasive plants is likely to vary depending on the sampling method employed. Methods with strong qualitative thoroughness for species detection often lack the intensity necessary to monitor vegetation change. Four sampling methods (systematic plot, stratified-random plot, modified Whittaker, and timed meander) in hemlock and red...

  18. COMPARISON OF TWO METHODS FOR THE DETECTION OF LISTERIA MONOCYTOGENES

    Directory of Open Access Journals (Sweden)

    G. Tantillo

    2013-02-01

    Full Text Available The aim of this study was to compare the performance of the conventional methods for detection of Listeria monocytogenes in food using media Oxford and ALOA (Agar Listeria acc. to Ottaviani & Agosti in according to the ISO 11290-1 to a new chromogenic medium “CHROMagar Listeria” standardized in 2005 AFNOR ( CHR – 21/1-12/01. A total of 40 pre-packed ready-to-eat food samples were examined. Using two methods six samples were found positive for Listeria monocytogenes but the medium “CHROMagar Listeria” was more selective in comparison with the others. In conclusion this study has demonstrated that isolation medium able to target specifically the detection of L. monocytogenes such as “CHROMagar Listeria” is highly recommendable because of that detection time is significantly reduced and the analysis cost is less expensive.

  19. A hybrid approach for efficient anomaly detection using metaheuristic methods

    Directory of Open Access Journals (Sweden)

    Tamer F. Ghanem

    2015-07-01

    Full Text Available Network intrusion detection based on anomaly detection techniques has a significant role in protecting networks and systems against harmful activities. Different metaheuristic techniques have been used for anomaly detector generation. Yet, reported literature has not studied the use of the multi-start metaheuristic method for detector generation. This paper proposes a hybrid approach for anomaly detection in large scale datasets using detectors generated based on multi-start metaheuristic method and genetic algorithms. The proposed approach has taken some inspiration of negative selection-based detector generation. The evaluation of this approach is performed using NSL-KDD dataset which is a modified version of the widely used KDD CUP 99 dataset. The results show its effectiveness in generating a suitable number of detectors with an accuracy of 96.1% compared to other competitors of machine learning algorithms.

  20. Determination of Efavirenz in Human Dried Blood Spots by Reversed-Phase High Performance Liquid Chromatography with UV Detection

    Science.gov (United States)

    Hoffman, Justin T; Rossi, Steven S; Espina-Quinto, Rowena; Letendre, Scott; Capparelli, Edmund V

    2013-01-01

    Background Previously published methods for determination of efavirenz (EFV) in human dried blood spots (DBS) employ costly and complex liquid chromatography/mass spectrometry. We describe the validation and evaluation of a simple and inexpensive high-performance liquid chromatography (HPLC) method for EFV quantification in human DBS and dried plasma spots (DPS), using ultraviolet (UV) detection appropriate for resource-limited settings. Methods 100μl of heparinized whole blood or plasma were spotted onto blood collection cards, dried, punched, and eluted. Eluates are injected onto a C-18 reversed phase HPLC column. EFV is separated isocratically using a potassium phosphate and ACN mobile phase. UV detection is at 245nm. Quantitation is by use of external calibration standards. Following validation, the method was evaluated using whole blood and plasma from HIV-positive patients undergoing EFV therapy. Results Mean recovery of drug from dried blood spots is 91.5%. The method is linear over the validated concentration range of 0.3125 – 20.0μg/mL. A good correlation (Spearman r=0.96) between paired plasma and DBS EFV concentrations from the clinical samples was observed, and hematocrit level was not found to be a significant determinant of the EFV DBS level. The mean observed CDBS/Cplasma ratio was 0.68. A good correlation (Spearman r=0.96) between paired plasma and DPS EFV concentrations from the clinical samples was observed. The mean percent deviation of DPS samples from plasma samples is 1.68%. Conclusions Dried whole blood spot or dried plasma spot sampling is well suited for monitoring EFV therapy in resource limited settings, particularly when high sensitivity is not essential. PMID:23503446

  1. Apparatus and method for detecting explosives

    International Nuclear Information System (INIS)

    Griffith, B.

    1976-01-01

    An apparatus is described for use in situations such as airports to detect explosives hidden in containers (for eg. suitcases). The method involves the evaluation of the quantities of oxygen and nitrogen within the container by neutron activation analysis and the determination of whether these quantities exceed predetermined limits. The equipment includes a small sub-critical lower powered reactor for thermal (0.01 to 0.10 eV) neutron production, a radium beryllium primary source, a deuterium-tritium reactor as a high energy (> 1.06 MeV) neutron source and Geiger counter detector arrays. (UK)

  2. Rapid detection of human fecal Eubacterium species and related genera by nested PCR method.

    Science.gov (United States)

    Kageyama, A; Benno, Y

    2001-01-01

    PCR procedures based on 16S rDNA gene sequence specific for seven Eubacterium spp. and Eggerthella lenta that predominate in the human intestinal tract were developed, and used for direct detection of these species in seven human feces samples. Three species of Eggerthella lenta, Eubacterium rectale, and Eubacterium eligens were detected from seven fecal samples. Eubacterium biforme was detected from six samples. It was reported that E. rectale, E. eligens, and E. biforme were difficult to detect by traditional culture method, but the nested PCR method is available for the detection of these species. This result shows that the nested PCR method utilizing a universal primer pair, followed by amplification with species-specific primers, would allow rapid detection of Eubacterium species in human feces.

  3. Bioanalytical methods for food allergy diagnosis, allergen detection and new allergen discovery.

    Science.gov (United States)

    Gasilova, Natalia; Girault, Hubert H

    2015-01-01

    For effective monitoring and prevention of the food allergy, one of the emerging health problems nowadays, existing diagnostic procedures and allergen detection techniques are constantly improved. Meanwhile, new methods are also developed, and more and more putative allergens are discovered. This review describes traditional methods and summarizes recent advances in the fast evolving field of the in vitro food allergy diagnosis, allergen detection in food products and discovery of the new allergenic molecules. A special attention is paid to the new diagnostic methods under laboratory development like various immuno- and aptamer-based assays, including immunoaffinity capillary electrophoresis. The latter technique shows the importance of MS application not only for the allergen detection but also for the allergy diagnosis.

  4. A DDoS Attack Detection Method Based on Hybrid Heterogeneous Multiclassifier Ensemble Learning

    Directory of Open Access Journals (Sweden)

    Bin Jia

    2017-01-01

    Full Text Available The explosive growth of network traffic and its multitype on Internet have brought new and severe challenges to DDoS attack detection. To get the higher True Negative Rate (TNR, accuracy, and precision and to guarantee the robustness, stability, and universality of detection system, in this paper, we propose a DDoS attack detection method based on hybrid heterogeneous multiclassifier ensemble learning and design a heuristic detection algorithm based on Singular Value Decomposition (SVD to construct our detection system. Experimental results show that our detection method is excellent in TNR, accuracy, and precision. Therefore, our algorithm has good detective performance for DDoS attack. Through the comparisons with Random Forest, k-Nearest Neighbor (k-NN, and Bagging comprising the component classifiers when the three algorithms are used alone by SVD and by un-SVD, it is shown that our model is superior to the state-of-the-art attack detection techniques in system generalization ability, detection stability, and overall detection performance.

  5. A Comparative Analysis of Pitch Detection Methods Under the Influence of Different Noise Conditions.

    Science.gov (United States)

    Sukhostat, Lyudmila; Imamverdiyev, Yadigar

    2015-07-01

    Pitch is one of the most important components in various speech processing systems. The aim of this study was to evaluate different pitch detection methods in terms of various noise conditions. Prospective study. For evaluation of pitch detection algorithms, time-domain, frequency-domain, and hybrid methods were considered by using Keele and CSTR speech databases. Each of them has its own advantages and disadvantages. Experiments have shown that BaNa method achieves the highest pitch detection accuracy. The development of methods for pitch detection, which are robust to additive noise at different signal-to-noise ratio, is an important field of research with many opportunities for enhancement the modern methods. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  6. Systems and methods for neutron detection using scintillator nano-materials

    Science.gov (United States)

    Letant, Sonia Edith; Wang, Tzu-Fang

    2016-03-08

    In one embodiment, a neutron detector includes a three dimensional matrix, having nanocomposite materials and a substantially transparent film material for suspending the nanocomposite materials, a detector coupled to the three dimensional matrix adapted for detecting a change in the nanocomposite materials, and an analyzer coupled to the detector adapted for analyzing the change detected by the detector. In another embodiment, a method for detecting neutrons includes receiving radiation from a source, converting neutrons in the radiation into alpha particles using converter material, converting the alpha particles into photons using quantum dot emitters, detecting the photons, and analyzing the photons to determine neutrons in the radiation.

  7. Anomaly Detection in Gas Turbine Fuel Systems Using a Sequential Symbolic Method

    Directory of Open Access Journals (Sweden)

    Fei Li

    2017-05-01

    Full Text Available Anomaly detection plays a significant role in helping gas turbines run reliably and economically. Considering the collective anomalous data and both sensitivity and robustness of the anomaly detection model, a sequential symbolic anomaly detection method is proposed and applied to the gas turbine fuel system. A structural Finite State Machine is used to evaluate posterior probabilities of observing symbolic sequences and the most probable state sequences they may locate. Hence an estimation-based model and a decoding-based model are used to identify anomalies in two different ways. Experimental results indicate that both models have both ideal performance overall, but the estimation-based model has a strong robustness ability, whereas the decoding-based model has a strong accuracy ability, particularly in a certain range of sequence lengths. Therefore, the proposed method can facilitate well existing symbolic dynamic analysis- based anomaly detection methods, especially in the gas turbine domain.

  8. Pretreatment Hematocrit Is Superior to Hemoglobin as a Prognostic Factor for Triple Negative Breast Cancer.

    Science.gov (United States)

    Chen, Bo; Dai, Danian; Tang, Hailin; Ai, Xiaohong; Chen, Xi; Zhang, Xiaoyan; Li, Zhiyan; Xie, Xiaoming

    2016-01-01

    Anemia usually refers to low hemoglobin (Hb) levels. Previous studies indicated that anemia negatively influence the survival in various cancers. Hematocrit (HCT) is the volume percentage of red blood cells in blood, which could indicate anemia in both individuals and populations. This study compared the value of HCT with that of Hb for predicting outcomes of patients who underwent treatment for triple negative breast cancer (TNBC). A retrospective study of 293 triple negative breast cancer patients, accepting treatment from January 2004 to December 2009 at Sun Yat-sen University Cancer Center, was conducted. Kaplan-Meier curves and multivariate Cox proportional models were used to calculate disease free survival (DFS) and overall survival (OS). The cut-off value of HCT was 35.9% determined by X-tile software analysis. The cut-off value of Hb was 12.0 g/dl based on the World Health Organization (WHO) criteria. In univariate analysis, low HCT and low Hb were both significantly associated with decreased DFS and OS. In multivariate analysis, HCT (HR: 0.570; 95% CI: 0.331-0.981, P = 0.042 for DFS; HR: 0.456; 95% CI: 0.256-0.813, P = 0.008 for OS) was still identified as independent predictor of outcome, but not Hb. Pretreatment low HCT is independently associated with poor prognosis in TNBC patients. However, HCT was found to be superior to Hb in terms of predicting breast cancer mortality. In the future, large-scale prospective studies or validation studies are needed to verify our findings.

  9. Detecting long-term growth trends using tree rings: a critical evaluation of methods.

    Science.gov (United States)

    Peters, Richard L; Groenendijk, Peter; Vlam, Mart; Zuidema, Pieter A

    2015-05-01

    Tree-ring analysis is often used to assess long-term trends in tree growth. A variety of growth-trend detection methods (GDMs) exist to disentangle age/size trends in growth from long-term growth changes. However, these detrending methods strongly differ in approach, with possible implications for their output. Here, we critically evaluate the consistency, sensitivity, reliability and accuracy of four most widely used GDMs: conservative detrending (CD) applies mathematical functions to correct for decreasing ring widths with age; basal area correction (BAC) transforms diameter into basal area growth; regional curve standardization (RCS) detrends individual tree-ring series using average age/size trends; and size class isolation (SCI) calculates growth trends within separate size classes. First, we evaluated whether these GDMs produce consistent results applied to an empirical tree-ring data set of Melia azedarach, a tropical tree species from Thailand. Three GDMs yielded similar results - a growth decline over time - but the widely used CD method did not detect any change. Second, we assessed the sensitivity (probability of correct growth-trend detection), reliability (100% minus probability of detecting false trends) and accuracy (whether the strength of imposed trends is correctly detected) of these GDMs, by applying them to simulated growth trajectories with different imposed trends: no trend, strong trends (-6% and +6% change per decade) and weak trends (-2%, +2%). All methods except CD, showed high sensitivity, reliability and accuracy to detect strong imposed trends. However, these were considerably lower in the weak or no-trend scenarios. BAC showed good sensitivity and accuracy, but low reliability, indicating uncertainty of trend detection using this method. Our study reveals that the choice of GDM influences results of growth-trend studies. We recommend applying multiple methods when analysing trends and encourage performing sensitivity and reliability

  10. Current perspectives on genetically modified crops and detection methods.

    Science.gov (United States)

    Kamle, Madhu; Kumar, Pradeep; Patra, Jayanta Kumar; Bajpai, Vivek K

    2017-07-01

    Genetically modified (GM) crops are the fastest adopted commodities in the agribiotech industry. This market penetration should provide a sustainable basis for ensuring food supply for growing global populations. The successful completion of two decades of commercial GM crop production (1996-2015) is underscored by the increasing rate of adoption of genetic engineering technology by farmers worldwide. With the advent of introduction of multiple traits stacked together in GM crops for combined herbicide tolerance, insect resistance, drought tolerance or disease resistance, the requirement of reliable and sensitive detection methods for tracing and labeling genetically modified organisms in the food/feed chain has become increasingly important. In addition, several countries have established threshold levels for GM content which trigger legally binding labeling schemes. The labeling of GM crops is mandatory in many countries (such as China, EU, Russia, Australia, New Zealand, Brazil, Israel, Saudi Arabia, Korea, Chile, Philippines, Indonesia, Thailand), whereas in Canada, Hong Kong, USA, South Africa, and Argentina voluntary labeling schemes operate. The rapid adoption of GM crops has increased controversies, and mitigating these issues pertaining to the implementation of effective regulatory measures for the detection of GM crops is essential. DNA-based detection methods have been successfully employed, while the whole genome sequencing using next-generation sequencing (NGS) technologies provides an advanced means for detecting genetically modified organisms and foods/feeds in GM crops. This review article describes the current status of GM crop commercialization and discusses the benefits and shortcomings of common and advanced detection systems for GMs in foods and animal feeds.

  11. Nucleic acid detection system and method for detecting influenza

    Science.gov (United States)

    Cai, Hong; Song, Jian

    2015-03-17

    The invention provides a rapid, sensitive and specific nucleic acid detection system which utilizes isothermal nucleic acid amplification in combination with a lateral flow chromatographic device, or DNA dipstick, for DNA-hybridization detection. The system of the invention requires no complex instrumentation or electronic hardware, and provides a low cost nucleic acid detection system suitable for highly sensitive pathogen detection. Hybridization to single-stranded DNA amplification products using the system of the invention provides a sensitive and specific means by which assays can be multiplexed for the detection of multiple target sequences.

  12. Statistical methods for estimating normal blood chemistry ranges and variance in rainbow trout (Salmo gairdneri), Shasta Strain

    Science.gov (United States)

    Wedemeyer, Gary A.; Nelson, Nancy C.

    1975-01-01

    Gaussian and nonparametric (percentile estimate and tolerance interval) statistical methods were used to estimate normal ranges for blood chemistry (bicarbonate, bilirubin, calcium, hematocrit, hemoglobin, magnesium, mean cell hemoglobin concentration, osmolality, inorganic phosphorus, and pH for juvenile rainbow (Salmo gairdneri, Shasta strain) trout held under defined environmental conditions. The percentile estimate and Gaussian methods gave similar normal ranges, whereas the tolerance interval method gave consistently wider ranges for all blood variables except hemoglobin. If the underlying frequency distribution is unknown, the percentile estimate procedure would be the method of choice.

  13. New method of silicon photovoltaic panel fault detection using impedance spectroscopy

    DEFF Research Database (Denmark)

    Symonowicz, Joanna Karolina; Riedel, Nicholas; Thorsteinsson, Sune

    2017-01-01

    The aim of our project is to develop a new method for photovoltaic (PV) panel fault detection based on analysing its impedance spectra (IS). Although this technique was successful in assessing the state of degradation of fuel cells and batteries [1, 2], it has never been applied to PV cells...... on a wide scale. In this paper, we show that, unlike current-voltage (I-V) tests, the IS method is capable of early detection of changes in PV panel parameters due to microcracks and potential-induced degradation (PID). Although our measurements are only successful under dark conditions, the results...... are similar for both laboratory environment and for outdoor tests in various weather conditions. A fully developed IS technique, accounting for all kinds of most common PV panel degradation types, would surpass the existing PV fault detection methods then it comes to cost and accuracy [3,4]....

  14. Detection methods for human enteric viruses in representative foods.

    Science.gov (United States)

    Leggitt, P R; Jaykus, L A

    2000-12-01

    Although viral foodborne disease is a significant problem, foods are rarely tested for viral contamination, and when done, testing is limited to shellfish commodities. In this work, we report a method to extract and detect human enteric viruses from alternative food commodities using an elution-concentration approach followed by detection using reverse transcription-polymerase chain reaction (RT-PCR). Fifty-gram lettuce or hamburger samples were artificially inoculated with poliovirus type 1 (PV1), hepatitis A virus (HAV), or the Norwalk virus and processed by the sequential steps of homogenization, filtration, Freon extraction (hamburger), and polyethylene glycol (PEG) precipitation. To reduce volumes further and remove RT-PCR inhibitors, a secondary PEG precipitation was necessary, resulting in an overall 10- to 20-fold sample size reduction from 50 g to 3 to 5 ml. Virus recoveries in secondary PEG concentrates ranged from 10 to 70% for PV1 and 2 to 4% for HAV as evaluated by mammalian cell culture infectivity assay. Total RNA from PEG concentrates was extracted to a small volume (30 to 40 microl) and subjected to RT-PCR amplification of viral RNA sequences. Detection limit studies indicated that viral RNA was consistently detected by RT-PCR at initial inoculum levels > or =102 PFU/50-g food sample for PV1 and > or =10(3) PFU/50-g food sample for HAV. In similar studies with the Norwalk virus, detection at inoculum levels > or =1.5 X 10(3) PCR-amplifiable units/50-g sample for both food products was possible. All RT-PCR amplicons were confirmed by subsequent Southern hybridization. The procedure reported represents progress toward the development of methods to detect human enteric viral contamination in foods other than shellfish.

  15. Methods of Run-Time Error Detection in Distributed Process Control Software

    DEFF Research Database (Denmark)

    Drejer, N.

    In this thesis, methods of run-time error detection in application software for distributed process control is designed. The error detection is based upon a monitoring approach in which application software is monitored by system software during the entire execution. The thesis includes definition...... and constraint evaluation is designed for the modt interesting error types. These include: a) semantical errors in data communicated between application tasks; b) errors in the execution of application tasks; and c) errors in the timing of distributed events emitted by the application software. The design...... of error detection methods includes a high level software specification. this has the purpose of illustrating that the designed can be used in practice....

  16. Current status of the EPR method to detect irradiated food

    International Nuclear Information System (INIS)

    Desrosiers, M.F.

    1996-01-01

    This review gives a brief outline of the principles of the EPR detection method for irradiated foods by food type. For each food type, the scope, limitations and status of the method are given. The extensive reference list aims to include all which define the method, as well as some rarely cited works of historical importance. (author)

  17. Plutonium, its occurrence in environment and methods of detection

    Energy Technology Data Exchange (ETDEWEB)

    Petr, I [Ceske Vysoke Uceni Technicke, Prague (Czechoslovakia). Fakulta Jaderna a Fysikalne Inzenyrska

    1977-12-01

    A brief survey is given of the physical properties of plutonium nuclides, their toxicity, values of maximum permissible annual intake, and their occurrence in the environment, and of their determination in water, soil, air and biological objects. The principles are stated of the individual methods of plutonium determination, i.e., the method of radiochemical analysis with subsequent detection or alpha spectrometry, the method of filter sampling of air with subsequent alpha spectrometry, coincidence alpha-beta spectrometry or radiochemical analysis, and the use of X and gamma spectrometry. A comparison of the different methods is presented.

  18. Damage detection and locating using tone burst and continuous excitation modulation method

    Science.gov (United States)

    Li, Zheng; Wang, Zhi; Xiao, Li; Qu, Wenzhong

    2014-03-01

    Among structural health monitoring techniques, nonlinear ultrasonic spectroscopy methods are found to be effective diagnostic approach to detecting nonlinear damage such as fatigue crack, due to their sensitivity to incipient structural changes. In this paper, a nonlinear ultrasonic modulation method was developed to detect and locate a fatigue crack on an aluminum plate. The method is different with nonlinear wave modulation method which recognizes the modulation of low-frequency vibration and high-frequency ultrasonic wave; it recognizes the modulation of tone burst and high-frequency ultrasonic wave. In the experiment, a Hanning window modulated sinusoidal tone burst and a continuous sinusoidal excitation were simultaneously imposed on the PZT array which was bonded on the surface of an aluminum plate. The modulations of tone burst and continuous sinusoidal excitation was observed in different actuator-sensor paths, indicating the presence and location of fatigue crack. The results of experiments show that the proposed method is capable of detecting and locating the fatigue crack successfully.

  19. Potential new methods of detection of irradiated food

    International Nuclear Information System (INIS)

    Raffi, J.J.

    1991-01-01

    The irradiation of food by X- and gamma-rays and by electron beams is a technological process which may be used for food preservation in addition to heat or chemical treatment. The role of the Community Bureau of Reference - the BCR programme - in this area is to support the development and the improvement of analytical methods required for the preparation and implementation of the European legislation. In this context, after consultation of specialists in the Member States and the EFTA countries, it was decided that the BCR should undertake a collaborative project for the identification of irradiated food. The aim of the Cadarache workshop was to examine the development of new methods of detection and to set up a concerted research action covering four areas: DNA based methods; microbiological and biological methods; physical methods; chemical methods

  20. Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe

    Directory of Open Access Journals (Sweden)

    Wan Hamat Wan Sofian

    2016-01-01

    Full Text Available Plastic pipe are widely used in many fields for the fluid or gaseous product conveyance but basic components of a plastic material made it very sensitive to damage, which requires techniques for detecting damage reliable and efficient. Ultrasonic guided wave is a sensitive method based on propagation of low-frequency excitation in solid structures for damage detection. Ultrasonic guided wave method are performed to investigate the effect of crack to the frequency signal using Fast Fourier Transform (FFT analysis. This paper researched to determine performance of ultrasonic guided wave method in order to detect crack in buried pipeline. It was found that for an uncrack pipe, FFT analysis shows one peak which is the operating frequency by the piezoelectric actuator itself while the FFT analysis for single cracked pipe shows two peak which is the operating frequency by the piezoelectric actuator itself and the resultant frequency from the crack. For multi cracked pipe, the frequency signal shows more than two peak depend the number of crack. The results presented here may facilitate improvements in the accuracy and precision of pipeline crack detection.

  1. Synthesis of present methods of surface contamination detection (skin, clothes, laboratories)

    International Nuclear Information System (INIS)

    Joudrier, P.

    1983-01-01

    The signification of the term ''contamination'' is briefly recalled. To measure the levels of contamination, there are only two methods: the direct method and the indirect method. Finally, the recent improvements in the surface contamination detection field are shortly reviewed [fr

  2. SuBSENSE: a universal change detection method with local adaptive sensitivity.

    Science.gov (United States)

    St-Charles, Pierre-Luc; Bilodeau, Guillaume-Alexandre; Bergevin, Robert

    2015-01-01

    Foreground/background segmentation via change detection in video sequences is often used as a stepping stone in high-level analytics and applications. Despite the wide variety of methods that have been proposed for this problem, none has been able to fully address the complex nature of dynamic scenes in real surveillance tasks. In this paper, we present a universal pixel-level segmentation method that relies on spatiotemporal binary features as well as color information to detect changes. This allows camouflaged foreground objects to be detected more easily while most illumination variations are ignored. Besides, instead of using manually set, frame-wide constants to dictate model sensitivity and adaptation speed, we use pixel-level feedback loops to dynamically adjust our method's internal parameters without user intervention. These adjustments are based on the continuous monitoring of model fidelity and local segmentation noise levels. This new approach enables us to outperform all 32 previously tested state-of-the-art methods on the 2012 and 2014 versions of the ChangeDetection.net dataset in terms of overall F-Measure. The use of local binary image descriptors for pixel-level modeling also facilitates high-speed parallel implementations: our own version, which used no low-level or architecture-specific instruction, reached real-time processing speed on a midlevel desktop CPU. A complete C++ implementation based on OpenCV is available online.

  3. Methods of detecting and controlling mucoid Pseudomonas biofilm production

    Science.gov (United States)

    Yu, Hongwei D. (Inventor); Qiu, Dongru (Inventor)

    2013-01-01

    Compositions and methods for detecting and controlling the conversion to mucoidy in Pseudomonas aeruginosa are disclosed. The present invention provides for detecting the switch from nonmucoid to mucoid state of P. aeruginosa by measuring mucE expression or MucE protein levels. The interaction between MucE and AlgW controls the switch to mucoidy in wild type P. aeruginosa. Also disclosed is an alginate biosynthesis heterologous expression system for use in screening candidate substances that inhibit conversion to mucoidy.

  4. Microscopy outperformed in a comparison of five methods for detecting Trichomonas vaginalis in symptomatic women.

    Science.gov (United States)

    Nathan, B; Appiah, J; Saunders, P; Heron, D; Nichols, T; Brum, R; Alexander, S; Baraitser, P; Ison, C

    2015-03-01

    In the UK, despite its low sensitivity, wet mount microscopy is often the only method of detecting Trichomonas vaginalis infection. A study was conducted in symptomatic women to compare the performance of five methods for detecting T. vaginalis: an in-house polymerase chain reaction (PCR); Aptima T. vaginalis kit; OSOM ®Trichomonas Rapid Test; culture and microscopy. Symptomatic women underwent routine testing; microscopy and further swabs were taken for molecular testing, OSOM and culture. A true positive was defined as a sample that was positive for T. vaginalis by two or more different methods. Two hundred and forty-six women were recruited: 24 patients were positive for T. vaginalis by two or more different methods. Of these 24 patients, 21 patients were detected by real-time PCR (sensitivity 88%); 22 patients were detected by the Aptima T. vaginalis kit (sensitivity 92%); 22 patients were detected by OSOM (sensitivity 92%); nine were detected by wet mount microscopy (sensitivity 38%); and 21 were detected by culture (sensitivity 88%). Two patients were positive by just one method and were not considered true positives. All the other detection methods had a sensitivity to detect T. vaginalis that was significantly greater than wet mount microscopy, highlighting the number of cases that are routinely missed even in symptomatic women if microscopy is the only diagnostic method available. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  5. INCREMENTAL PRINCIPAL COMPONENT ANALYSIS BASED OUTLIER DETECTION METHODS FOR SPATIOTEMPORAL DATA STREAMS

    Directory of Open Access Journals (Sweden)

    A. Bhushan

    2015-07-01

    Full Text Available In this paper, we address outliers in spatiotemporal data streams obtained from sensors placed across geographically distributed locations. Outliers may appear in such sensor data due to various reasons such as instrumental error and environmental change. Real-time detection of these outliers is essential to prevent propagation of errors in subsequent analyses and results. Incremental Principal Component Analysis (IPCA is one possible approach for detecting outliers in such type of spatiotemporal data streams. IPCA has been widely used in many real-time applications such as credit card fraud detection, pattern recognition, and image analysis. However, the suitability of applying IPCA for outlier detection in spatiotemporal data streams is unknown and needs to be investigated. To fill this research gap, this paper contributes by presenting two new IPCA-based outlier detection methods and performing a comparative analysis with the existing IPCA-based outlier detection methods to assess their suitability for spatiotemporal sensor data streams.

  6. Study on Method of Geohazard Change Detection Based on Integrating Remote Sensing and GIS

    International Nuclear Information System (INIS)

    Zhao, Zhenzhen; Yan, Qin; Liu, Zhengjun; Luo, Chengfeng

    2014-01-01

    Following a comprehensive literature review, this paper looks at analysis of geohazard using remote sensing information. This paper compares the basic types and methods of change detection, explores the basic principle of common methods and makes an respective analysis of the characteristics and shortcomings of the commonly used methods in the application of geohazard. Using the earthquake in JieGu as a case study, this paper proposes a geohazard change detection method integrating RS and GIS. When detecting the pre-earthquake and post-earthquake remote sensing images at different phases, it is crucial to set an appropriate threshold. The method adopts a self-adapting determination algorithm for threshold. We select a training region which is obtained after pixel information comparison and set a threshold value. The threshold value separates the changed pixel maximum. Then we apply the threshold value to the entire image, which could also make change detection accuracy maximum. Finally, we output the result to the GIS system to make change analysis. The experimental results show that this method of geohazard change detection based on integrating remote sensing and GIS information has higher accuracy with obvious advantages compared with the traditional methods

  7. Correction to the count-rate detection limit and sample/blank time-allocation methods

    International Nuclear Information System (INIS)

    Alvarez, Joseph L.

    2013-01-01

    A common form of count-rate detection limits contains a propagation of uncertainty error. This error originated in methods to minimize uncertainty in the subtraction of the blank counts from the gross sample counts by allocation of blank and sample counting times. Correct uncertainty propagation showed that the time allocation equations have no solution. This publication presents the correct form of count-rate detection limits. -- Highlights: •The paper demonstrated a proper method of propagating uncertainty of count rate differences. •The standard count-rate detection limits were in error. •Count-time allocation methods for minimum uncertainty were in error. •The paper presented the correct form of the count-rate detection limit. •The paper discussed the confusion between count-rate uncertainty and count uncertainty

  8. Evaluation of real-time PCR detection methods for detecting rice products contaminated by rice genetically modified with a CpTI-KDEL-T-nos transgenic construct.

    Science.gov (United States)

    Nakamura, Kosuke; Akiyama, Hiroshi; Kawano, Noriaki; Kobayashi, Tomoko; Yoshimatsu, Kayo; Mano, Junichi; Kitta, Kazumi; Ohmori, Kiyomi; Noguchi, Akio; Kondo, Kazunari; Teshima, Reiko

    2013-12-01

    Genetically modified (GM) rice (Oryza sativa) lines, such as insecticidal Kefeng and Kemingdao, have been developed and found unauthorised in processed rice products in many countries. Therefore, qualitative detection methods for the GM rice are required for the GM food regulation. A transgenic construct for expressing cowpea (Vigna unguiculata) trypsin inhibitor (CpTI) was detected in some imported processed rice products contaminated with Kemingdao. The 3' terminal sequence of the identified transgenic construct for expression of CpTI included an endoplasmic reticulum retention signal coding sequence (KDEL) and nopaline synthase terminator (T-nos). The sequence was identical to that in a report on Kefeng. A novel construct-specific real-time polymerase chain reaction (PCR) detection method for detecting the junction region sequence between the CpTI-KDEL and T-nos was developed. The imported processed rice products were evaluated for the contamination of the GM rice using the developed construct-specific real-time PCR methods, and detection frequency was compared with five event-specific detection methods. The construct-specific detection methods detected the GM rice at higher frequency than the event-specific detection methods. Therefore, we propose that the construct-specific detection method is a beneficial tool for screening the contamination of GM rice lines, such as Kefeng, in processed rice products for the GM food regulation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Point-of-Care Hemoglobin/Hematocrit Testing: Comparison of Methodology and Technology.

    Science.gov (United States)

    Maslow, Andrew; Bert, Arthur; Singh, Arun; Sweeney, Joseph

    2016-04-01

    Point-of-care (POC) testing allows rapid assessment of hemoglobin (Hgb) and hematocrit (Hct) values. This study compared 3 POC testing devices--the Radical-7 pulse oximeter (Radical-7, Neuchȃtel, Switzerland), the i-STAT (Abbott Point of Care, Princeton, NJ), and the GEM 4000 (Instrumentation Laboratory, Bedford, MA)--to the hospital reference device, the UniCel DxH 800 (Beckman Coulter, Brea, CA) in cardiac surgery patients. Prospective study. Tertiary care cardiovascular center. Twenty-four consecutive elective adult cardiac surgery patients. Hgb and Hct values were measured using 3 POC devices (the Radical-7, i-STAT, and GEM 4000) and a reference laboratory device (UniCel DxH 800). Data were collected simultaneously before surgery, after heparin administration, after heparin reversal with protamine, and after sternal closure. Data were analyzed using bias analyses. POC testing data were compared with that of the reference laboratory device. Hgb levels ranged from 6.8 to 15.1 g/dL, and Hct levels ranged from 20.1% to 43.8%. The overall mean bias was lowest with the i-STAT (Hct, 0.22%; Hgb 0.05 g/dL) compared with the GEM 4000 (Hct, 2.15%; Hgb, 0.63 g/dL) and the Radical-7 (Hgb 1.16 g/dL). The range of data for the i-STAT and Radical-7 was larger than that with the GEM 4000, and the pattern or slopes changed significantly with the i-STAT and Radical-7, whereas that of the GEM 4000 remained relatively stable. The GEM 4000 demonstrated a consistent overestimation of laboratory data, which tended to improve after bypass and at lower Hct/Hgb levels. The i-STAT bias changed from overestimation to underestimation, the latter in the post-cardiopulmonary bypass period and at lower Hct/Hgb levels. By contrast, the Radical-7 biases increased during the surgical procedure and in the lower ranges of Hgb. Important clinical differences and limitations were found among the 3 POC testing devices that should caution clinicians from relying on these data as sole determinants of

  10. Research on pipeline leak detection method based on pressure and dynamic pressure

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Likun; Xiong, Min; Zhao, Jinyun; Wang, Hongchao; Xu, Bin; Yu, DongLiang; Sun, Yi; Cai, Yongjun [RnD center of PetroChina Pipeline Company, Langfang, Hebei, (China)

    2010-07-01

    Pipeline leakages are very frequent and need to be detected as fast as possible to avoid safety and environment issues. Many leakage detection processes have been developed. Acoustic wave methods based on static pressure and dynamic pressure are both used for pipeline leakage detection. This study investigated a new pipeline leak detection method based on joint pressure and dynamic pressure. A dynamic pressure transmitter was designed based on a piezoelectric dynamic pressure sensor. The study showed that the dynamic pressure signal should be used for pipeline leak detection with a quick-change in pipeline internal pressure, while the static pressure signal provides better results with a slow-change of pipeline internal pressure. The in-field results showed that the location error of dynamic pressure is reduced to 80 m with a leakage ratio of 0.6 % pipeline throughput.

  11. Lagrangian based methods for coherent structure detection

    Energy Technology Data Exchange (ETDEWEB)

    Allshouse, Michael R., E-mail: mallshouse@chaos.utexas.edu [Center for Nonlinear Dynamics and Department of Physics, University of Texas at Austin, Austin, Texas 78712 (United States); Peacock, Thomas, E-mail: tomp@mit.edu [Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    2015-09-15

    There has been a proliferation in the development of Lagrangian analytical methods for detecting coherent structures in fluid flow transport, yielding a variety of qualitatively different approaches. We present a review of four approaches and demonstrate the utility of these methods via their application to the same sample analytic model, the canonical double-gyre flow, highlighting the pros and cons of each approach. Two of the methods, the geometric and probabilistic approaches, are well established and require velocity field data over the time interval of interest to identify particularly important material lines and surfaces, and influential regions, respectively. The other two approaches, implementing tools from cluster and braid theory, seek coherent structures based on limited trajectory data, attempting to partition the flow transport into distinct regions. All four of these approaches share the common trait that they are objective methods, meaning that their results do not depend on the frame of reference used. For each method, we also present a number of example applications ranging from blood flow and chemical reactions to ocean and atmospheric flows.

  12. DNS Tunneling Detection Method Based on Multilabel Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Ahmed Almusawi

    2018-01-01

    Full Text Available DNS tunneling is a method used by malicious users who intend to bypass the firewall to send or receive commands and data. This has a significant impact on revealing or releasing classified information. Several researchers have examined the use of machine learning in terms of detecting DNS tunneling. However, these studies have treated the problem of DNS tunneling as a binary classification where the class label is either legitimate or tunnel. In fact, there are different types of DNS tunneling such as FTP-DNS tunneling, HTTP-DNS tunneling, HTTPS-DNS tunneling, and POP3-DNS tunneling. Therefore, there is a vital demand to not only detect the DNS tunneling but rather classify such tunnel. This study aims to propose a multilabel support vector machine in order to detect and classify the DNS tunneling. The proposed method has been evaluated using a benchmark dataset that contains numerous DNS queries and is compared with a multilabel Bayesian classifier based on the number of corrected classified DNS tunneling instances. Experimental results demonstrate the efficacy of the proposed SVM classification method by obtaining an f-measure of 0.80.

  13. Comparison of new immunofluorescence method for detection of soy protein in meat products with immunohistochemical, histochemical, and ELISA methods

    Directory of Open Access Journals (Sweden)

    Michaela Petrášová

    2014-01-01

    Full Text Available Soy proteins are commonly used in the food industry thanks to their technological properties. However, soy is, along with cow’s milk, eggs, wheat, peanuts, tree nuts, fish, crustaceans, and molluscs, responsible for around 90% of food allergies, and is also one of the foodstuffs that can cause anaphylaxis. The aim of this work was to compare the immunofluorescence method for the detection of soy protein in meat products purchased from the retail market with other microscopic methods (immunohistochemical and histochemical, with the ELISA reference method and with the confirmatory results. Within the research, 127 meat products purchased in the retail network were examined using the immunofluorescence method used for the detection of soy protein. The method was compared to Enzyme-Linked ImmunoSorbent Assay (ELISA, immunohistochemical, and histochemical methods. According to McNemar’s test, non-compliance between the immunofluorescence method and immunohistochemical method was low. In addition, a significant difference between the fluorescence method and ELISA (P P < 0.01 was found. The immunofluorescence method was also compared with confirmatory results. According to McNemar’s test, non-compliance between the immunofluorescence method and confirmatory results was low. The results showed the possibilities of this new method to detect the content of soy protein in meat products.

  14. A new method for face detection in colour images for emotional bio-robots

    Institute of Scientific and Technical Information of China (English)

    HAPESHI; Kevin

    2010-01-01

    Emotional bio-robots have become a hot research topic in last two decades. Though there have been some progress in research, design and development of various emotional bio-robots, few of them can be used in practical applications. The study of emotional bio-robots demands multi-disciplinary co-operation. It involves computer science, artificial intelligence, 3D computation, engineering system modelling, analysis and simulation, bionics engineering, automatic control, image processing and pattern recognition etc. Among them, face detection belongs to image processing and pattern recognition. An emotional robot must have the ability to recognize various objects, particularly, it is very important for a bio-robot to be able to recognize human faces from an image. In this paper, a face detection method is proposed for identifying any human faces in colour images using human skin model and eye detection method. Firstly, this method can be used to detect skin regions from the input colour image after normalizing its luminance. Then, all face candidates are identified using an eye detection method. Comparing with existing algorithms, this method only relies on the colour and geometrical data of human face rather than using training datasets. From experimental results, it is shown that this method is effective and fast and it can be applied to the development of an emotional bio-robot with further improvements of its speed and accuracy.

  15. Botulinum Neurotoxin Detection Methods for Public Health Response and Surveillance

    Directory of Open Access Journals (Sweden)

    Nagarajan Thirunavukkarasu

    2018-06-01

    Full Text Available Botulism outbreak due to consumption of food contaminated with botulinum neurotoxins (BoNTs is a public health emergency. The threat of bioterrorism through deliberate distribution in food sources and/or aerosolization of BoNTs raises global public health and security concerns due to the potential for high mortality and morbidity. Rapid and reliable detection methods are necessary to support clinical diagnosis and surveillance for identifying the source of contamination, performing epidemiological analysis of the outbreak, preventing and responding to botulism outbreaks. This review considers the applicability of various BoNT detection methods and examines their fitness-for-purpose in safeguarding the public health and security goals.

  16. An improved electrochemiluminescence polymerase chain reaction method for highly sensitive detection of plant viruses

    International Nuclear Information System (INIS)

    Tang Yabing; Xing Da; Zhu Debin; Liu Jinfeng

    2007-01-01

    Recently, we have reported an electrochemiluminescence polymerase chain reaction (ECL-PCR) method for detection of genetically modified organisms. The ECL-PCR method was further improved in the current study by introducing a multi-purpose nucleic acid sequence that was specific to the tris(bipyridine) ruthenium (TBR) labeled probe, into the 5' terminal of the primers. The method was applied to detect plant viruses. Conserved sequence of the plant viruses was amplified by PCR. The product was hybridized with a biotin labeled probe and a TBR labeled probe. The hybridization product was separated by streptavidin-coated magnetic beads, and detected by measuring the ECL signals of the TBR labeled. Under the optimized conditions, the experiment results show that the detection limit is 50 fmol of PCR products, and the signal-to-noise ratio is in excess of 14.6. The method was used to detect banana streak virus, banana bunchy top virus, and papaya leaf curl virus. The experiment results show that this method could reliably identity viruses infected plant samples. The improved ECL-PCR approach has higher sensitivity and lower cost than previous approach. It can effectively detect the plant viruses with simplicity, stability, and high sensitivity

  17. Thermoluminescence method for detection of irradiated food

    International Nuclear Information System (INIS)

    Pinnioja, S.

    1998-01-01

    A method of thermoluminescence (TL) analysis was developed for the detection of irradiated foods. The TL method is based on the determination of thermoluminescence of adhering or contaminating minerals separated from foods by wet sieving and treatment with high density liquid. Carbon tetrachloride provided a suitable alternative for foods that form gels with water. Thermoluminescence response of minerals in a first TL measurement is normalised with a second TL measurement of the same mineral sample after calibration irradiation to a dose of 5 kGy. The decision about irradiation is made on the basis of a comparison of the two TL spectra: if the two TL glow curves match in shape and intensity the sample has been irradiated, and if they are clearly different it has not been irradiated. An attractive feature of TL analysis is that the mineral material itself is used for calibration; no reference material is required. Foods of interest in the investigation were herbs, spices, berries and seafood. The presence of minerals in samples is a criterion for application of the method, and appropriate minerals were found in all herbs, spices and berries. The most common minerals in terrestrial food were tecto-silicates - quartz and feldspars - which with their intense and stable thermoluminescence were well suited for the analysis. Mica proved to be useless for detection purposes, whereas carbonate in the form of calcite separated from intestines of seafood was acceptable. Fading of the TL signal is considerable in the low temperature part of the glow curve during a storage of several months after irradiation. However, spices and herbs could easily be identified as irradiated even after two years storage. Conditions for seafood, which is stored in a freezer, are different, and only slight fading was observed after one year. The effect of mineral composition and structure on TL was studied for feldspars. Feldspars originating from subtropical and tropical regions exhibit lower TL

  18. Thermoluminescence method for detection of irradiated food

    Energy Technology Data Exchange (ETDEWEB)

    Pinnioja, S

    1998-12-31

    A method of thermoluminescence (TL) analysis was developed for the detection of irradiated foods. The TL method is based on the determination of thermoluminescence of adhering or contaminating minerals separated from foods by wet sieving and treatment with high density liquid. Carbon tetrachloride provided a suitable alternative for foods that form gels with water. Thermoluminescence response of minerals in a first TL measurement is normalised with a second TL measurement of the same mineral sample after calibration irradiation to a dose of 5 kGy. The decision about irradiation is made on the basis of a comparison of the two TL spectra: if the two TL glow curves match in shape and intensity the sample has been irradiated, and if they are clearly different it has not been irradiated. An attractive feature of TL analysis is that the mineral material itself is used for calibration; no reference material is required. Foods of interest in the investigation were herbs, spices, berries and seafood. The presence of minerals in samples is a criterion for application of the method, and appropriate minerals were found in all herbs, spices and berries. The most common minerals in terrestrial food were tecto-silicates - quartz and feldspars - which with their intense and stable thermoluminescence were well suited for the analysis. Mica proved to be useless for detection purposes, whereas carbonate in the form of calcite separated from intestines of seafood was acceptable. Fading of the TL signal is considerable in the low temperature part of the glow curve during a storage of several months after irradiation. However, spices and herbs could easily be identified as irradiated even after two years storage. Conditions for seafood, which is stored in a freezer, are different, and only slight fading was observed after one year. The effect of mineral composition and structure on TL was studied for feldspars. Feldspars originating from subtropical and tropical regions exhibit lower TL

  19. Comparison of three methods for detection of melamine in compost and soil

    International Nuclear Information System (INIS)

    Tian, Yongqiang; Chen, Liming; Gao, Lihong; Wu, Manli; Dick, Warren A.

    2012-01-01

    Recent product recalls and food safety incidents due to melamine (MM) adulteration or contamination have caused a worldwide food security concern. This has led to many methods being developed to detect MM in foods, but few methods haves been reported that can rapidly and reliably measure MM in environmental samples. To meet this need, a high performance liquid chromatography (HPLC) with UV detection method, an enzyme-linked immunosorbent assay (ELISA) test kit, and an enzyme-linked rapid colorimetric assay (RCA) test kit were evaluated for their ability to accurately measure MM concentrations in compost and soil samples. All three methods accurately detected MM concentrations if no MM degradation products, such as ammeline (AMN), ammelide (AMD) and cyanuric acid (CA), were present in an aqueous sample. In the presence of these MM degradation products, the HPLC yielded more accurate concentrations than the ELISA method and there was no significant (P > 0.05) difference between the HPLC and RCA methods. However, if samples were purified by SPE or prepared with blocking buffer, the ELISA method accurately measured MM concentrations, even in the presence of the MM degradation products. The HPLC method generally outperformed the RCA method for measuring MM in soil extracts but gave similar results for compost extracts. The number of samples that can be analyzed by the ELISA and RCA methods in a 24-hour time period is much greater than by the HPLC method. Thus the RCA method would seem to be a good screening method for measuring MM in compost and soil samples and the results obtained could then be confirmed by the HPLC method. The HPLC method, however, also allows simultaneous measurement of MM and its degradation products of AMD, AMN and CA. - Highlights: ► We detected melamine in environmental samples by three methods. ► ELISA can measures melamine in an environmental sample if a blocking buffer is used. ► A rapid colorimetric assay (RCA) rapidly screens

  20. A Photoluminescence-Based Field Method for Detection of Traces of Explosives

    Directory of Open Access Journals (Sweden)

    E. Roland Menzel

    2004-01-01

    Full Text Available We report a photoluminescence-based field method for detecting traces of explosives. In its standard version, the method utilizes a commercially available color spot test kit for treating explosive traces on filter paper after swabbing. The colored products are fluorescent under illumination with a laser that operates on three C-size flashlight batteries and delivers light at 532 nm. In the fluorescence detection mode, by visual inspection, the typical sensitivity gain is a factor of 100. The method is applicable to a wide variety of explosives. In its time-resolved version, intended for in situ work, explosives are tagged with europium complexes. Instrumentation-wise, the time-resolved detection, again visual, can be accomplished in facile fashion. The europium luminescence excitation utilizes a laser operating at 355 nm. We demonstrate the feasibility of CdSe quantum dot sensitization of europium luminescence for time-resolved purposes. This would allow the use of the above 532 nm laser.

  1. [Detection of protein-protein interactions by FRET and BRET methods].

    Science.gov (United States)

    Matoulková, E; Vojtěšek, B

    2014-01-01

    Nowadays, in vivo protein-protein interaction studies have become preferable detecting meth-ods that enable to show or specify (already known) protein interactions and discover their inhibitors. They also facilitate detection of protein conformational changes and discovery or specification of signaling pathways in living cells. One group of in vivo methods enabling these findings is based on fluorescent resonance energy transfer (FRET) and its bio-luminescent modification (BRET). They are based on visualization of protein-protein interactions via light or enzymatic excitation of fluorescent or bio-luminescent proteins. These methods allow not only protein localization within the cell or its organelles (or small animals) but they also allow us to quantify fluorescent signals and to discover weak or strong interaction partners. In this review, we explain the principles of FRET and BRET, their applications in the characterization of protein-protein interactions and we describe several findings using these two methods that clarify molecular and cellular mechanisms and signals related to cancer biology.

  2. Comparison of soft-input-soft-output detection methods for dual-polarized quadrature duobinary system

    Science.gov (United States)

    Chang, Chun; Huang, Benxiong; Xu, Zhengguang; Li, Bin; Zhao, Nan

    2018-02-01

    Three soft-input-soft-output (SISO) detection methods for dual-polarized quadrature duobinary (DP-QDB), including maximum-logarithmic-maximum-a-posteriori-probability-algorithm (Max-log-MAP)-based detection, soft-output-Viterbi-algorithm (SOVA)-based detection, and a proposed SISO detection, which can all be combined with SISO decoding, are presented. The three detection methods are investigated at 128 Gb/s in five-channel wavelength-division-multiplexing uncoded and low-density-parity-check (LDPC) coded DP-QDB systems by simulations. Max-log-MAP-based detection needs the returning-to-initial-states (RTIS) process despite having the best performance. When the LDPC code with a code rate of 0.83 is used, the detecting-and-decoding scheme with the SISO detection does not need RTIS and has better bit error rate (BER) performance than the scheme with SOVA-based detection. The former can reduce the optical signal-to-noise ratio (OSNR) requirement (at BER=10-5) by 2.56 dB relative to the latter. The application of the SISO iterative detection in LDPC-coded DP-QDB systems makes a good trade-off between requirements on transmission efficiency, OSNR requirement, and transmission distance, compared with the other two SISO methods.

  3. A Precise Visual Method for Narrow Butt Detection in Specular Reflection Workpiece Welding

    Directory of Open Access Journals (Sweden)

    Jinle Zeng

    2016-09-01

    Full Text Available During the complex path workpiece welding, it is important to keep the welding torch aligned with the groove center using a visual seam detection method, so that the deviation between the torch and the groove can be corrected automatically. However, when detecting the narrow butt of a specular reflection workpiece, the existing methods may fail because of the extremely small groove width and the poor imaging quality. This paper proposes a novel detection method to solve these issues. We design a uniform surface light source to get high signal-to-noise ratio images against the specular reflection effect, and a double-line laser light source is used to obtain the workpiece surface equation relative to the torch. Two light sources are switched on alternately and the camera is synchronized to capture images when each light is on; then the position and pose between the torch and the groove can be obtained nearly at the same time. Experimental results show that our method can detect the groove effectively and efficiently during the welding process. The image resolution is 12.5 μm and the processing time is less than 10 ms per frame. This indicates our method can be applied to real-time narrow butt detection during high-speed welding process.

  4. DNA extraction methods for panbacterial and panfungal PCR detection in intraocular fluids.

    Science.gov (United States)

    Mazoteras, Paloma; Bispo, Paulo José Martins; Höfling-Lima, Ana Luisa; Casaroli-Marano, Ricardo P

    2015-07-01

    Three different methods of DNA extraction from intraocular fluids were compared with subsequent detection for bacterial and fungal DNA by universal PCR amplification. Three DNA extraction methods, from aqueous and vitreous humors, were evaluated to compare their relative efficiency. Bacterial (Gram positive and negative) and fungal strains were used in this study: Escherichia coli, Staphylococcus epidermidis and Candida albicans. The quality, quantification, and detection limit for DNA extraction and PCR amplification were analyzed. Validation procedures for 13 aqueous humor and 14 vitreous samples, from 20 patients with clinically suspected endophthalmitis were carried out. The column-based extraction method was the most time-effective, achieving DNA detection limits ≥10(2) and 10(3 )CFU/100 µL for bacteria and fungi, respectively. PCR amplification detected 100 fg, 1 pg and 10 pg of genomic DNA of E. coli, S. epidermidis and C. albicans respectively. PCR detected 90.0% of the causative agents from 27 intraocular samples collected from 20 patients with clinically suspected endophthalmitis, while standard microbiological techniques could detect only 60.0%. The most frequently found organisms were Streptococcus spp. in 38.9% (n = 7) of patients and Staphylococcus spp. found in 22.2% (n = 4). The column-based extraction method for very small inocula in small volume samples (50-100 µL) of aqueous and/or vitreous humors allowed PCR amplification in all samples with sufficient quality for subsequent sequencing and identification of the microorganism in the majority of them.

  5. Detection of heavy-water leaks in nuclear reactors : a novel method

    International Nuclear Information System (INIS)

    Murthy, M.S.; Gor, M.K.

    2002-01-01

    Technical Physics and Prototype Engineering Division, BARC has designed, developed and produced several high sensitivity mass spectrometer helium leak detectors over a period of two decades. Sometimes back, when there was a problem of detecting heavy water leaks in situ in one of the nuclear power reactors of the Department of Atomic Energy, it was referred to this division for a technical solution. After discussing with the site engineers, the various problems involved in the on-line detection of heavy water leaks especially near the end fittings of the coolant assemblies, a novel method of leak detection was developed. Some of the salient features of the method and the results obtained in the laboratory tests are given in this paper. (author)

  6. Methodologies for the practical determination and use of method detection limits

    International Nuclear Information System (INIS)

    Rucker, T.L.

    1995-01-01

    Method detection limits have often been misunderstood and misused. The basic definitions developed by Lloyd Currie and others have been combined with assumptions that are inappropriate for many types of radiochemical analyses. A partical way for determining detection limits based on Currie's basic definition is presented that removes the reliance on assumptions and that accounts for the total measurement uncertainty. Examples of proper and improper use of detection limits are also presented, including detection limits reported by commercial software for gamma spectroscopy and neutron activation analyses. (author) 6 refs.; 2 figs

  7. Intercomparisons to establish official methods for the detection of irradiated foods

    International Nuclear Information System (INIS)

    Spiegelberg, A.; Schulzki, G.; Bogl, K.W.; Schreiber, G.A.

    1994-01-01

    Irradiation of food for the purpose of extension of shelf life, control of microbial load, reduction of pathogenic microorganisms and disinfection is considered by many consumers with suspicion. Our studies concentrate on the establishment of official methods suitable for routine control measurements. Special emphasis is given to following methods: thermoluminescence (TL) analysis of minerals isolated from various foods, like spices, herbs, dried vegetables, teas, fruits or vegetables; electron spin resonance (ESR) spectroscopy of food components or whole foods that have a low water content, such as bones, first bones, shells, peels seeds, pips or dried fruits and detection of volatile hydrocarbons in the lipid fraction of fat containing food by gas-chromatographic analysis (GC). All three methods have been tested on a variety of foods within large scale intercomparisons between German food controlling laboratories. In Germany official methods could be established for detection of irradiated spices, spice mixtures and fruits by TL, of meat with bones, nuts and fish by ESR, and of chicken, pork and beef meat by GC. The latest intercomparisons have tested these methods for the detection of potatoes and shrimps by TL, of red paper and shrimps by ESR and of mangoes, papayas, avocados and cheese - by GC. Results were presented. (author)

  8. Robust fault detection of linear systems using a computationally efficient set-membership method

    DEFF Research Database (Denmark)

    Tabatabaeipour, Mojtaba; Bak, Thomas

    2014-01-01

    In this paper, a computationally efficient set-membership method for robust fault detection of linear systems is proposed. The method computes an interval outer-approximation of the output of the system that is consistent with the model, the bounds on noise and disturbance, and the past measureme...... is trivially parallelizable. The method is demonstrated for fault detection of a hydraulic pitch actuator of a wind turbine. We show the effectiveness of the proposed method by comparing our results with two zonotope-based set-membership methods....

  9. Edge detection of barium-filled stomach picture by one-dimensional collation method

    International Nuclear Information System (INIS)

    Nakamura, Shizuo

    1983-01-01

    The method for the contour edge detection of barium- filled stomach pictures by X-ray for the automatic screening is described using computer technique. It is necessary for the automatic screening of barium- filling pictures to detect accurately the outline of stomachs because the analysis of repletion pictures is performed by checking the disorder of marginal contours and abnormal stomach shapes. However, the detection of the coutour lines is difficult to be successful for the reason that the contrast of stomach pictures to background is low, a stomach is not necessarily filled completely with barium and the shadow of barium flowing into intestines is superimposed on stomach images and the shading is likely to occur. The engineering processing against these problems is not yet solved. In order to reduce the noise due to differential operator, the proposed method determines the boundary of a thing generally by the threshold value of density, and defines the edge of the thing from the differential waveform of density in the vicinity of the boundary. In addition, the method corrects the detection error caused by the local nonconformity of parameters by comparing the edges between the adjacent lines. As a result, in spite of its simple algorithm, the edges with good continuity and less noise can be detected, and the method is not much affected by shading. This method was found to be applicable to the images of others than stomachs. The extraction of the contour of barium- filling pictures requires the high level recognition processing instead of the simple conditioning. (Wakatsuki, Y.)

  10. Comparison of floods non-stationarity detection methods: an Austrian case study

    Science.gov (United States)

    Salinas, Jose Luis; Viglione, Alberto; Blöschl, Günter

    2016-04-01

    Non-stationarities in flood regimes have a huge impact in any mid and long term flood management strategy. In particular the estimation of design floods is very sensitive to any kind of flood non-stationarity, as they should be linked to a return period, concept that can be ill defined in a non-stationary context. Therefore it is crucial when analyzing existent flood time series to detect and, where possible, attribute flood non-stationarities to changing hydroclimatic and land-use processes. This works presents the preliminary results of applying different non-stationarity detection methods on annual peak discharges time series over more than 400 gauging stations in Austria. The kind of non-stationarities analyzed include trends (linear and non-linear), breakpoints, clustering beyond stochastic randomness, and detection of flood rich/flood poor periods. Austria presents a large variety of landscapes, elevations and climates that allow us to interpret the spatial patterns obtained with the non-stationarity detection methods in terms of the dominant flood generation mechanisms.

  11. Comparison of methods for accurate end-point detection of potentiometric titrations

    Science.gov (United States)

    Villela, R. L. A.; Borges, P. P.; Vyskočil, L.

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper.

  12. Comparison of methods for accurate end-point detection of potentiometric titrations

    International Nuclear Information System (INIS)

    Villela, R L A; Borges, P P; Vyskočil, L

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper

  13. Method of detecting leakage from sealing attached to pressure tube

    International Nuclear Information System (INIS)

    Tomomatsu, Ken-ichi; Hayashi, Ken-ichi.

    1990-01-01

    The present invention provides a detection method for measuring the amount of water leaked from sealings attached to the lower end of a pressure tube. That is, the lower end of the pressure tube is sealed only by a metal sealing. A capturing vessel is placed under the pressure tube for capturing the leaked water dropping from the lower end of the pressure tube and the weight of the leaked water is measured on every capturing vessels to determine the amount of the leaked water. The leakage detection method based on the weight measurement has higher accuracy compared with a conventional volume measuring method using a water level gauge as described below. For example, if the volume of the captured water is 10cc, an error of about 0.1cc is caused by the volume measuring method using the water level gauge, whereas if 10g (10cc) weight of water is measured by using an accurate balance, error is only about 10 -4 g (10 -4 cc). Accordingly, the method of the present invention can measure at an accuracy about 1000 times as high as the conventional method. (I.S.)

  14. A Hybrid Vision-Map Method for Urban Road Detection

    Directory of Open Access Journals (Sweden)

    Carlos Fernández

    2017-01-01

    Full Text Available A hybrid vision-map system is presented to solve the road detection problem in urban scenarios. The standardized use of machine learning techniques in classification problems has been merged with digital navigation map information to increase system robustness. The objective of this paper is to create a new environment perception method to detect the road in urban environments, fusing stereo vision with digital maps by detecting road appearance and road limits such as lane markings or curbs. Deep learning approaches make the system hard-coupled to the training set. Even though our approach is based on machine learning techniques, the features are calculated from different sources (GPS, map, curbs, etc., making our system less dependent on the training set.

  15. General survey of detection methods for irradiation foods

    International Nuclear Information System (INIS)

    Yang, J. S.

    1997-01-01

    The development of detection techniques is needed, in order for regulating authorities to determine whether or not a particular food sample has been irradiated, and label it accordingly so that a consumer's free choice can be exercised. The chemical and physical changes brought about in foods by practical doses of irradiation are very small, and therefore very sensitive methods are required. A number of promising approaches have been developed and evaluated. These include chemical, physical and biological methods ranging from the very simple to highly sophisticated techniques. (author)

  16. Detection of hazardous cavities with combined geophysical methods

    Science.gov (United States)

    Hegymegi, Cs.; Nyari, Zs.; Pattantyus-Abraham, M.

    2003-04-01

    Unknown near-surface cavities often cause problems for municipal communities all over the world. This is the situation in Hungary in many towns and villages, too. Inhabitants and owners of real estates (houses, cottages, lands) are responsible for the safety and stability of their properties. The safety of public sites belongs to the local municipal community. Both (the owner and the community) are interested in preventing accidents. Near-surface cavities (unknown caves or earlier built and forgotten cellars) usually can be easily detected by surface geophysical methods. Traditional and recently developed measuring techniques in seismics, geoelectrics and georadar are suitable for economical investigation of hazardous, potentially collapsing cavities, prior to excavation and reinforcement. This poster will show some example for detection of cellars and caves being dangerous for civil population because of possible collapse under public sites (road, yard, playground, agricultural territory, etc.). The applied and presented methods are ground penetrating radar, seismic surface tomography and analysis of single traces, geoelectric 2D and 3D resistivity profiling. Technology and processing procedure will be presented.

  17. Detection of a periodic structure hidden in random background: the role of signal amplitude in the matched filter detection method

    International Nuclear Information System (INIS)

    Vani, V C; Chatterjee, S

    2010-01-01

    The matched filter method for detecting a periodic structure on a surface hidden behind randomness is known to detect up to (r 0 /Λ)≥0.11, where r 0 is the coherence length of light on scattering from the rough part and Λ is the wavelength of the periodic part of the surface-the above limit being much lower than what is allowed by conventional detection methods. The primary goal of this technique is the detection and characterization of the periodic structure hidden behind randomness without the use of any complicated experimental or computational procedures. This paper examines this detection procedure for various values of the amplitude a of the periodic part beginning from a=0 to small finite values of a. We thus address the importance of the following quantities: '(a/λ)', which scales the amplitude of the periodic part with the wavelength of light, and (r 0 /Λ), in determining the detectability of the intensity peaks.

  18. Development of active acoustic method for water leak detection of LMFBR steam generators

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Yoshida, Kazuo; Kinoshita, Izumi

    2001-01-01

    In order to prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of fast breeder reactors (FBRs), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method, which detects the sound attenuation due to bubbles generated in the sodium-water reactions, is being developed. In this study, in order to evaluate the detection sensitivity of the active method, the signal processing methods for emitter and receiver and the detection method for leakage are investigated experimentally. In-water experiments performed by using an SG full-sector model that simulates the actual SGs. As an experimental result, the received sound attenuation for 10s was more than 10dB from air bubble injection when injected bubble of 10 l/s (equivalence water leak rate about 10 g/s.) The attenuation of sound are least affected by bubble injection position of heat transfer tubes bunch department. It is clarified that the background noise hardly influenced water leak detection performance as a result of having examined influence of background noise. (author)

  19. An efficient cloud detection method for high resolution remote sensing panchromatic imagery

    Science.gov (United States)

    Li, Chaowei; Lin, Zaiping; Deng, Xinpu

    2018-04-01

    In order to increase the accuracy of cloud detection for remote sensing satellite imagery, we propose an efficient cloud detection method for remote sensing satellite panchromatic images. This method includes three main steps. First, an adaptive intensity threshold value combined with a median filter is adopted to extract the coarse cloud regions. Second, a guided filtering process is conducted to strengthen the textural features difference and then we conduct the detection process of texture via gray-level co-occurrence matrix based on the acquired texture detail image. Finally, the candidate cloud regions are extracted by the intersection of two coarse cloud regions above and we further adopt an adaptive morphological dilation to refine them for thin clouds in boundaries. The experimental results demonstrate the effectiveness of the proposed method.

  20. Scintigraphic detection of peptic lesions with the method of radiolabelled sucralfate

    International Nuclear Information System (INIS)

    Naumovski, J.; Kovkarova, E.; Simova, N.; Janevik-Ivanovska, E.; Georgievska- Kuzmanovska, S.

    2003-01-01

    Background. Sucralfate is an antiulcer agent that after peroral application strongly adheres to mucosal defects and in that way provides a protective barrier to further damage from acid and pepsin. If radiolabelled with a gamma isotope, it could be detected under a gamma camera pointing lesions to which it adhered. With the aim to confirm a suitable noninvasive method for investigation of caustic lesions of the upper gastrointestinal tract we evaluated in a preliminary study the validity of the radiolabelled Sucralfate scintigraphy in detection of peptic disease. Patients and methods. With that purpose, 35 patients after an endoscopic examination underwent scintigraphy with Tc-99m-DTPA sucralfate. Patients were divided in two groups: a group of 20 patients with endoscopic confirmed peptic disease and a control group of 15 persons who had not any disease of the upper gastrointestinal tract. Results. Using the test for clinical evaluation of a new method, the scan showed sensitivity of 75 %, specificity of 100 % and accuracy of 85.7 %. Conclusions. Scintigraphy with Tc-99m-DTPA Sucralfate promoting it as an additional method, complementary to routine investigations in detecting mucosal lesions. (author)

  1. Comparison of detection methods for extended-spectrum beta-lactamases in Escherichia coli strains

    Directory of Open Access Journals (Sweden)

    Ewelina Kałużna

    2014-06-01

    Full Text Available Introduction: Detection of extended-spectrum beta-lactamases (ESBLs could be a major challenge for microbiologists – the difficulties arise mainly from the phenotypic differences among strains.Materials and Methods: Evaluation of ESBLs was performed on 42 strains of E. coli by: 1 DDST on MHA, 2 DDST on MHA with cloxacillin, 3 CT on MHA, according to CLSI, 4 CT on MHA with cloxacillin, 5 Etest ESBL (AB Biodisk, 6 CHROMagarTM ESBL (GRASO, 7 ChromID® ESBL (bioMérieux, and 8 automatic system VITEK2 ESBL test (bioMérieux.Result: Positive results were obtained for 20 strains using method 1, for 18 strains using method 2, 17 by method 3, 14 by method 4, 11 by method 5, 39 by method 6, 40 by method 7, and 15 by method 8. Using Etest ESBL 6.0 non-determinable results were obtained. The most consistent results were obtained when comparing the results of method 3 with results of method 2 (97.6%, and comparing the results obtained using methods 3 and 8 (95.2%.Conclusions: Based on our study we conclude that the chromogenic media can only be used as a screening method for the detection of ESBLs in E. coli rods. Etest is less useful compared to other phenotype methods, due to the impossibility of obtaining results for all the tested strains. Adding cloxacillin to MHA does not increase the frequency of detection of ESBLs in E. coli strains. DDST seems to be the most reliable among phenotypic methods for the detection of ESBLs in E. coli rods.

  2. EEMD-based multiscale ICA method for slewing bearing fault detection and diagnosis

    Science.gov (United States)

    Žvokelj, Matej; Zupan, Samo; Prebil, Ivan

    2016-05-01

    A novel multivariate and multiscale statistical process monitoring method is proposed with the aim of detecting incipient failures in large slewing bearings, where subjective influence plays a minor role. The proposed method integrates the strengths of the Independent Component Analysis (ICA) multivariate monitoring approach with the benefits of Ensemble Empirical Mode Decomposition (EEMD), which adaptively decomposes signals into different time scales and can thus cope with multiscale system dynamics. The method, which was named EEMD-based multiscale ICA (EEMD-MSICA), not only enables bearing fault detection but also offers a mechanism of multivariate signal denoising and, in combination with the Envelope Analysis (EA), a diagnostic tool. The multiscale nature of the proposed approach makes the method convenient to cope with data which emanate from bearings in complex real-world rotating machinery and frequently represent the cumulative effect of many underlying phenomena occupying different regions in the time-frequency plane. The efficiency of the proposed method was tested on simulated as well as real vibration and Acoustic Emission (AE) signals obtained through conducting an accelerated run-to-failure lifetime experiment on a purpose-built laboratory slewing bearing test stand. The ability to detect and locate the early-stage rolling-sliding contact fatigue failure of the bearing indicates that AE and vibration signals carry sufficient information on the bearing condition and that the developed EEMD-MSICA method is able to effectively extract it, thereby representing a reliable bearing fault detection and diagnosis strategy.

  3. Photostimulated luminescence, fast method of detection of irradiated foodstuffs

    International Nuclear Information System (INIS)

    Guzik, G.P.; Stachowicz, W.

    2005-01-01

    The principle of pulsed photostimulated luminescence (PPSL) method, description of instrumentation and methodology of measurements are presented. The pathway of operational procedure and testing of the PPSL instrument in the Laboratory for Detection of Irradiated Food of the Institute of Nuclear Chemistry and Technology are described. Attention has been paid to the positives of the new method while some limitation of its application have been also discussed. (author)

  4. Parameters of explosives detection through tagged neutron method

    Energy Technology Data Exchange (ETDEWEB)

    Bagdasaryan, Kh.E.; Batyaev, V.F.; Belichenko, S.G., E-mail: consul757@mail.ru; Bestaev, R.R.; Gavryuchenkov, A.V.; Karetnikov, M.D.

    2015-06-01

    The potentialities of tagged neutron method (TNM) for explosives detection are examined on the basis of an idealized geometrical model. The model includes ING-27 14 MeV neutron generator with a built-in α-detector, a LYSO γ-detector and samples of material to be identified of approximately 0.3 kg each: explosives imitators (trinitrotoluene - TNT, tetryl, RDX and ammonium nitrate), legal materials (sugar, water, silk and polyethylene). The samples were unshielded or shielded by a paper layer of various thicknesses. The experimental data were interpreted by numerical simulation using a Poisson distribution of signals with the statistical parameters defined experimentally. The detection parameters were obtained by a pattern classification theory and a Bayes classifier.

  5. Effect of fibrinogen on blood coagulation detected by optical coherence tomography

    International Nuclear Information System (INIS)

    Xu, Xiangqun; Teng, Xiangshuai

    2015-01-01

    Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d 1/e ) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d 1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0–8 g L −1 ); and 2) native plasma with commercial Fbg added (0–8 g L −1 ). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels. (paper)

  6. A new detection method based on CFAR and DE for OFPS

    Science.gov (United States)

    Qiu, Zezheng; Zheng, Tong; Qu, Hongquan; Pang, Liping

    2016-09-01

    Optical fiber pre-warning system (OFPS) is widely utilized in pipeline transport fields. The intrusions of OFPS need to be located. In this system, the original signals consist of noises, interferences, and intrusion signals. Here, noises are background and harmless interferences possessing with high power, and the intrusion signals are the main target of detection in this system. Hence, the study stresses on extracting the intrusion signals from the total ones. The proposed method can be divided into two parts, constant false alarm rate (CFAR) and dilation and erosion (DE). The former is applied to eliminate noises, and the latter is to remove interferences. According to some researches, the feature of noise background accords with the CFAR spatial detection. Furthermore, the detection results after CFAR can be presented as a binary image of time and space. Besides, interferences are relatively disconnected. Consequently, they can be eliminated by DE which is introduced from the image processing. To sum up, this novel method is based on CFAR and DE which can eliminate noises and interferences effectively. Moreover, it performs a brilliant detection performance. A series of tests were developed in Men Tou Gou of Beijing, China, and the reliability of proposed method can be verified by these tests.

  7. Microlensing of unresolved stars as a brown dwarf detection method

    CERN Document Server

    Bouquet, Alain; Melchior, Anne-Laure; Giraud-Heraud, Yannick; Baillon, Paul

    1993-01-01

    We describe a project of brown dwarf detection in the dark halo of a galaxy using the microlensing effect. We argue that monitoring pixels instead of stars could provide an enhancement in the number of detectable events. We estimate the detection efficiency with a Monte-Carlo simulation. We expect a ten-fold increase with respect to current experiments. To assess the feasibility of this method we have determined the photometric precision of a pixel by comparing several pictures of a same field in the LMC. To be published in the Proceeding of the workshop 'The dark side of the universe...', Roma, Juin 1993,

  8. Recent and innovative methods for detection of bacteremia and fungemia

    International Nuclear Information System (INIS)

    Reller, L.B.

    1983-01-01

    Advances continue to be made in methods for more reliable or more rapid means of detecting bacteremia and fungemia. The importance of blood sample volume and broth dilution has been established in controlled studies. New technology includes the use of resins that remove antimicrobials from blood samples, detection of radioactivity from organisms given radiolabeled substrate, use of dyes that stain microbial DNA and RNA, use of slides coated with growth media, and lysis-centrifugation for trapping microorganisms. Technology now being considered includes counterimmunoelectrophoresis, head-space gas chromatography, electrical impedance, microcalorimetry, and the use of lasers to detect pH changes and turbidity

  9. Feasibility of geophysical methods as a tool to detect urban subsurface cavity

    Science.gov (United States)

    Bang, E.; Kim, C.; Rim, H.; Ryu, D.; Lee, H.; Jeong, S. W.; Jung, B.; Yum, B. W.

    2016-12-01

    Urban road collapse problem become a social issue in Korea these days. Underground cavity cannot be cured by itself, we need to detect existing underground cavity before road collapse. We should consider cost, reliability, availability, skill requirement for field work and interpretation procedure in selecting detecting method because it's huge area and very long length to complete. We constructed a real-scale ground model for this purpose. Its size is about 15m*8m*3m (L*W*D) and sewer pipes are buried at the depth of 1.2m. We modeled upward moving or enlargement of underground cavity by digging the ground through the hole of sewer pipe inside. There are two or three steps having different cavity size and depth. We performed all five methods on the ground model to monitor ground collapse and detect underground cavity at each step. The first one is GPR method, which is very popular for this kind of project. GPR provided very good images showing underground cavity well at each step. DC resistivity survey is also selected because it is a common tool to locate underground anomaly. It provided the images showing underground cavity, but field setup is not favorable for the project. The third method is micro gravity method which can differentiate cavity zone from gravity distribution. Micro Gravity gave smaller g values around the cavity compared to normal condition, but it takes very long time to perform. The fourth method is thermal image. The temperature of the ground surface on the cavity will be different from the other area. We used multi-copter for rapid thermal imaging and we could pick the area of underground cavity from the aerial thermal image of ground surface. The last method we applied is RFID/magnetic survey. When the ground is collapsed around the buried RFID/magnetic tag in depth, tag will be moved downward. We can know the ground collapse through checking tag detecting condition. We could pick the area of ground collapse easily. When we compared each

  10. Method for detecting clusters of possible uranium deposits

    International Nuclear Information System (INIS)

    Conover, W.J.; Bement, T.R.; Iman, R.L.

    1978-01-01

    When a two-dimensional map contains points that appear to be scattered somewhat at random, a question that often arises is whether groups of points that appear to cluster are merely exhibiting ordinary behavior, which one can expect with any random distribution of points, or whether the clusters are too pronounced to be attributable to chance alone. A method for detecting clusters along a straight line is applied to the two-dimensional map of 214 Bi anomalies observed as part of the National Uranium Resource Evaluation Program in the Lubbock, Texas, region. Some exact probabilities associated with this method are computed and compared with two approximate methods. The two methods for approximating probabilities work well in the cases examined and can be used when it is not feasible to obtain the exact probabilities

  11. Stochastic Industrial Source Detection Using Lower Cost Methods

    Science.gov (United States)

    Thoma, E.; George, I. J.; Brantley, H.; Deshmukh, P.; Cansler, J.; Tang, W.

    2017-12-01

    Hazardous air pollutants (HAPs) can be emitted from a variety of sources in industrial facilities, energy production, and commercial operations. Stochastic industrial sources (SISs) represent a subcategory of emissions from fugitive leaks, variable area sources, malfunctioning processes, and improperly controlled operations. From the shared perspective of industries and communities, cost-effective detection of mitigable SIS emissions can yield benefits such as safer working environments, cost saving through reduced product loss, lower air shed pollutant impacts, and improved transparency and community relations. Methods for SIS detection can be categorized by their spatial regime of operation, ranging from component-level inspection to high-sensitivity kilometer scale surveys. Methods can be temporally intensive (providing snap-shot measures) or sustained in both time-integrated and continuous forms. Each method category has demonstrated utility, however, broad adoption (or routine use) has thus far been limited by cost and implementation viability. Described here are a subset of SIS methods explored by the U.S EPA's next generation emission measurement (NGEM) program that focus on lower cost methods and models. An emerging systems approach that combines multiple forms to help compensate for reduced performance factors of lower cost systems is discussed. A case study of a multi-day HAP emission event observed by a combination of low cost sensors, open-path spectroscopy, and passive samplers is detailed. Early field results of a novel field gas chromatograph coupled with a fast HAP concentration sensor is described. Progress toward near real-time inverse source triangulation assisted by pre-modeled facility profiles using the Los Alamos Quick Urban & Industrial Complex (QUIC) model is discussed.

  12. Solid state nuclear track detection principles, methods and applications

    CERN Document Server

    Durrani, S A; ter Haar, D

    1987-01-01

    Solid State Nuclear Track Detection: Principles, Methods and Applications is the second book written by the authors after Nuclear Tracks in Solids: Principles and Applications. The book is meant as an introduction to the subject solid state of nuclear track detection. The text covers the interactions of charged particles with matter; the nature of the charged-particle track; the methodology and geometry of track etching; thermal fading of latent damage trails on tracks; the use of dielectric track recorders in particle identification; radiation dossimetry; and solid state nuclear track detecti

  13. Cloud detection method for Chinese moderate high resolution satellite imagery (Conference Presentation)

    Science.gov (United States)

    Zhong, Bo; Chen, Wuhan; Wu, Shanlong; Liu, Qinhuo

    2016-10-01

    Cloud detection of satellite imagery is very important for quantitative remote sensing research and remote sensing applications. However, many satellite sensors don't have enough bands for a quick, accurate, and simple detection of clouds. Particularly, the newly launched moderate to high spatial resolution satellite sensors of China, such as the charge-coupled device on-board the Chinese Huan Jing 1 (HJ-1/CCD) and the wide field of view (WFV) sensor on-board the Gao Fen 1 (GF-1), only have four available bands including blue, green, red, and near infrared bands, which are far from the requirements of most could detection methods. In order to solve this problem, an improved and automated cloud detection method for Chinese satellite sensors called OCM (Object oriented Cloud and cloud-shadow Matching method) is presented in this paper. It firstly modified the Automatic Cloud Cover Assessment (ACCA) method, which was developed for Landsat-7 data, to get an initial cloud map. The modified ACCA method is mainly based on threshold and different threshold setting produces different cloud map. Subsequently, a strict threshold is used to produce a cloud map with high confidence and large amount of cloud omission and a loose threshold is used to produce a cloud map with low confidence and large amount of commission. Secondly, a corresponding cloud-shadow map is also produced using the threshold of near-infrared band. Thirdly, the cloud maps and cloud-shadow map are transferred to cloud objects and cloud-shadow objects. Cloud and cloud-shadow are usually in pairs; consequently, the final cloud and cloud-shadow maps are made based on the relationship between cloud and cloud-shadow objects. OCM method was tested using almost 200 HJ-1/CCD images across China and the overall accuracy of cloud detection is close to 90%.

  14. Non-coding RNA detection methods combined to improve usability, reproducibility and precision

    Directory of Open Access Journals (Sweden)

    Kreikemeyer Bernd

    2010-09-01

    Full Text Available Abstract Background Non-coding RNAs gain more attention as their diverse roles in many cellular processes are discovered. At the same time, the need for efficient computational prediction of ncRNAs increases with the pace of sequencing technology. Existing tools are based on various approaches and techniques, but none of them provides a reliable ncRNA detector yet. Consequently, a natural approach is to combine existing tools. Due to a lack of standard input and output formats combination and comparison of existing tools is difficult. Also, for genomic scans they often need to be incorporated in detection workflows using custom scripts, which decreases transparency and reproducibility. Results We developed a Java-based framework to integrate existing tools and methods for ncRNA detection. This framework enables users to construct transparent detection workflows and to combine and compare different methods efficiently. We demonstrate the effectiveness of combining detection methods in case studies with the small genomes of Escherichia coli, Listeria monocytogenes and Streptococcus pyogenes. With the combined method, we gained 10% to 20% precision for sensitivities from 30% to 80%. Further, we investigated Streptococcus pyogenes for novel ncRNAs. Using multiple methods--integrated by our framework--we determined four highly probable candidates. We verified all four candidates experimentally using RT-PCR. Conclusions We have created an extensible framework for practical, transparent and reproducible combination and comparison of ncRNA detection methods. We have proven the effectiveness of this approach in tests and by guiding experiments to find new ncRNAs. The software is freely available under the GNU General Public License (GPL, version 3 at http://www.sbi.uni-rostock.de/moses along with source code, screen shots, examples and tutorial material.

  15. Detecting Malware with an Ensemble Method Based on Deep Neural Network

    Directory of Open Access Journals (Sweden)

    Jinpei Yan

    2018-01-01

    Full Text Available Malware detection plays a crucial role in computer security. Recent researches mainly use machine learning based methods heavily relying on domain knowledge for manually extracting malicious features. In this paper, we propose MalNet, a novel malware detection method that learns features automatically from the raw data. Concretely, we first generate a grayscale image from malware file, meanwhile extracting its opcode sequences with the decompilation tool IDA. Then MalNet uses CNN and LSTM networks to learn from grayscale image and opcode sequence, respectively, and takes a stacking ensemble for malware classification. We perform experiments on more than 40,000 samples including 20,650 benign files collected from online software providers and 21,736 malwares provided by Microsoft. The evaluation result shows that MalNet achieves 99.88% validation accuracy for malware detection. In addition, we also take malware family classification experiment on 9 malware families to compare MalNet with other related works, in which MalNet outperforms most of related works with 99.36% detection accuracy and achieves a considerable speed-up on detecting efficiency comparing with two state-of-the-art results on Microsoft malware dataset.

  16. A method of detecting sea fogs using CALIOP data and its application to improve MODIS-based sea fog detection

    International Nuclear Information System (INIS)

    Wu, Dong; Lu, Bo; Zhang, Tianche; Yan, Fengqi

    2015-01-01

    A method to detect sea fogs from the measurement data acquired by the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) aboard the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) satellite is proposed in this paper. Because of the unique capability of vertical-resolved measurements, sea fogs and low clouds can be more easily distinguished in the CALIOP data compared with passive satellite measurements. Yellow Sea where sea fogs occur frequently is selected to test the method. Nine cases of daytime sea fog events from 2008 to 2011 in the Yellow Sea are studied intensively to characterize the remotely sensed radiation properties of various targets, such as clear-sky sea surface, sea fog, low cloud and high cloud. These fog cases are then used in an attempt to evaluate sea fogs identified from the MODIS measurements. The method proposed in this paper can also be used for nighttime cases. Multi-year sea fog dataset can be made from the CALIOP measurement and used to validate the MODIS sea fog detection. - Highlights: • A method of sea fog detection from the CALIOP measurements is proposed. • CALIOP VFM and 532-nm attenuated backscatter products are integrated used. • Sea fogs and low clouds can be more easily distinguished in the CALIOP data. • 9 Cases of daytime sea fog events in the Yellow Sea are selected to test the method. • The MODIS sea fog detections are evaluated using the collocated CALIOP data

  17. Preface to the Focus Issue: Chaos Detection Methods and Predictability

    International Nuclear Information System (INIS)

    Gottwald, Georg A.; Skokos, Charalampos

    2014-01-01

    This Focus Issue presents a collection of papers originating from the workshop Methods of Chaos Detection and Predictability: Theory and Applications held at the Max Planck Institute for the Physics of Complex Systems in Dresden, June 17–21, 2013. The main aim of this interdisciplinary workshop was to review comprehensively the theory and numerical implementation of the existing methods of chaos detection and predictability, as well as to report recent applications of these techniques to different scientific fields. The collection of twelve papers in this Focus Issue represents the wide range of applications, spanning mathematics, physics, astronomy, particle accelerator physics, meteorology and medical research. This Preface surveys the papers of this Issue

  18. Preface to the Focus Issue: chaos detection methods and predictability.

    Science.gov (United States)

    Gottwald, Georg A; Skokos, Charalampos

    2014-06-01

    This Focus Issue presents a collection of papers originating from the workshop Methods of Chaos Detection and Predictability: Theory and Applications held at the Max Planck Institute for the Physics of Complex Systems in Dresden, June 17-21, 2013. The main aim of this interdisciplinary workshop was to review comprehensively the theory and numerical implementation of the existing methods of chaos detection and predictability, as well as to report recent applications of these techniques to different scientific fields. The collection of twelve papers in this Focus Issue represents the wide range of applications, spanning mathematics, physics, astronomy, particle accelerator physics, meteorology and medical research. This Preface surveys the papers of this Issue.

  19. Multi person detection and tracking based on hierarchical level-set method

    Science.gov (United States)

    Khraief, Chadia; Benzarti, Faouzi; Amiri, Hamid

    2018-04-01

    In this paper, we propose an efficient unsupervised method for mutli-person tracking based on hierarchical level-set approach. The proposed method uses both edge and region information in order to effectively detect objects. The persons are tracked on each frame of the sequence by minimizing an energy functional that combines color, texture and shape information. These features are enrolled in covariance matrix as region descriptor. The present method is fully automated without the need to manually specify the initial contour of Level-set. It is based on combined person detection and background subtraction methods. The edge-based is employed to maintain a stable evolution, guide the segmentation towards apparent boundaries and inhibit regions fusion. The computational cost of level-set is reduced by using narrow band technique. Many experimental results are performed on challenging video sequences and show the effectiveness of the proposed method.

  20. Detection of Dew-Point by substantial Raman Band Frequency Jumps (A new Method)

    DEFF Research Database (Denmark)

    Hansen, Susanne Brunsgaard; Berg, Rolf W.; Stenby, Erling Halfdan

    Detection of Dew-Point by substantial Raman Band Frequency Jumps (A new Method). See poster at http://www.kemi.dtu.dk/~ajo/rolf/jumps.pdf......Detection of Dew-Point by substantial Raman Band Frequency Jumps (A new Method). See poster at http://www.kemi.dtu.dk/~ajo/rolf/jumps.pdf...

  1. Characterizing Dynamic Walking Patterns and Detecting Falls with Wearable Sensors Using Gaussian Process Methods

    Directory of Open Access Journals (Sweden)

    Taehwan Kim

    2017-05-01

    Full Text Available By incorporating a growing number of sensors and adopting machine learning technologies, wearable devices have recently become a prominent health care application domain. Among the related research topics in this field, one of the most important issues is detecting falls while walking. Since such falls may lead to serious injuries, automatically and promptly detecting them during daily use of smartphones and/or smart watches is a particular need. In this paper, we investigate the use of Gaussian process (GP methods for characterizing dynamic walking patterns and detecting falls while walking with built-in wearable sensors in smartphones and/or smartwatches. For the task of characterizing dynamic walking patterns in a low-dimensional latent feature space, we propose a novel approach called auto-encoded Gaussian process dynamical model, in which we combine a GP-based state space modeling method with a nonlinear dimensionality reduction method in a unique manner. The Gaussian process methods are fit for this task because one of the most import strengths of the Gaussian process methods is its capability of handling uncertainty in the model parameters. Also for detecting falls while walking, we propose to recycle the latent samples generated in training the auto-encoded Gaussian process dynamical model for GP-based novelty detection, which can lead to an efficient and seamless solution to the detection task. Experimental results show that the combined use of these GP-based methods can yield promising results for characterizing dynamic walking patterns and detecting falls while walking with the wearable sensors.

  2. Development of a general method for detection and quantification of the P35S promoter based on assessment of existing methods

    Science.gov (United States)

    Wu, Yuhua; Wang, Yulei; Li, Jun; Li, Wei; Zhang, Li; Li, Yunjing; Li, Xiaofei; Li, Jun; Zhu, Li; Wu, Gang

    2014-01-01

    The Cauliflower mosaic virus (CaMV) 35S promoter (P35S) is a commonly used target for detection of genetically modified organisms (GMOs). There are currently 24 reported detection methods, targeting different regions of the P35S promoter. Initial assessment revealed that due to the absence of primer binding sites in the P35S sequence, 19 of the 24 reported methods failed to detect P35S in MON88913 cotton, and the other two methods could only be applied to certain GMOs. The rest three reported methods were not suitable for measurement of P35S in some testing events, because SNPs in binding sites of the primer/probe would result in abnormal amplification plots and poor linear regression parameters. In this study, we discovered a conserved region in the P35S sequence through sequencing of P35S promoters from multiple transgenic events, and developed new qualitative and quantitative detection systems targeting this conserved region. The qualitative PCR could detect the P35S promoter in 23 unique GMO events with high specificity and sensitivity. The quantitative method was suitable for measurement of P35S promoter, exhibiting good agreement between the amount of template and Ct values for each testing event. This study provides a general P35S screening method, with greater coverage than existing methods. PMID:25483893

  3. A new method of small target detection based on neural network

    Science.gov (United States)

    Hu, Jing; Hu, Yongli; Lu, Xinxin

    2018-02-01

    The detection and tracking of moving dim target in infrared image have been an research hotspot for many years. The target in each frame of images only occupies several pixels without any shape and structure information. Moreover, infrared small target is often submerged in complicated background with low signal-to-clutter ratio, making the detection very difficult. Different backgrounds exhibit different statistical properties, making it becomes extremely complex to detect the target. If the threshold segmentation is not reasonable, there may be more noise points in the final detection, which is unfavorable for the detection of the trajectory of the target. Single-frame target detection may not be able to obtain the desired target and cause high false alarm rate. We believe the combination of suspicious target detection spatially in each frame and temporal association for target tracking will increase reliability of tracking dim target. The detection of dim target is mainly divided into two parts, In the first part, we adopt bilateral filtering method in background suppression, after the threshold segmentation, the suspicious target in each frame are extracted, then we use LSTM(long short term memory) neural network to predict coordinates of target of the next frame. It is a brand-new method base on the movement characteristic of the target in sequence images which could respond to the changes in the relationship between past and future values of the values. Simulation results demonstrate proposed algorithm can effectively predict the trajectory of the moving small target and work efficiently and robustly with low false alarm.

  4. Comprehensive methods for earlier detection and monitoring of forest decline

    Science.gov (United States)

    Jennifer Pontius; Richard Hallett

    2014-01-01

    Forested ecosystems are threatened by invasive pests, pathogens, and unusual climatic events brought about by climate change. Earlier detection of incipient forest health problems and a quantitatively rigorous assessment method is increasingly important. Here, we describe a method that is adaptable across tree species and stress agents and practical for use in the...

  5. DIGITAL DETECTION SYSTEM DESIGN OF MYCOBACTERIUM TUBERCULOSIS THROUGH EXTRACTION OF SPUTUM IMAGE USING NEURAL NETWORK METHOD

    Directory of Open Access Journals (Sweden)

    Franky Arisgraha

    2012-01-01

    Full Text Available Tuberculosis (TBC is an dangerous disease and many people has been infected. One of many important steps to control TBC effectively and efficiently is by increasing case finding using right method and accurate diagnostic. One of them is to detect Mycobacterium Tuberculosis inside sputum. Conventional detection of Mycobacterium Tuberculosis inside sputum can need a lot of time, so digitally detection method of Mycobacterium Tuberculosis was designed as an effort to get better result of detection. This method was designed by using combination between digital image processing method and Neural Network method. From testing report that was done, Mycobacterium can be detected with successful value reach 77.5% and training error less than 5%.

  6. Spectroscopic methods for detection of impurities in water

    Science.gov (United States)

    Strashnikova, Natalia V.; Papiashvili, Nona; Cohen-Luria, Rivka; Mark, Shlomo; Shilon, Guy; Khankin, Daniel; Kalisky, Yehoshua; Kalisky, Ofra; Parola, Abraham H.

    2011-11-01

    Optical photoluminescence spectroscopic method for detection of impurities, hazardous materials, pesticides, and pollutants in water resources, both qualitatively and quantitatively, is presented. The method is based on synchronous fluorescence spectroscopy (SFS) of organic aromatic compounds, or poly-aromatic hydrocarbons (PAH), and is carried out by following simultaneously their excitation and emission spectra. The full excitation emission matrix (EEM) generated in this way provides a 2-D and 3-D fluorescence map of the tested sample and the diagonals through the axes origin provide the synchronous fluorescence spectra at a constant wavelengths differences between the emission and excitation wavelengths, thus enabling multitude components identification. This map contains all the relevant spectroscopic information of the tested sample, and serves as a unique "fingerprint" with a very specific and accurate identification. When compared with pre-determined spectra and calibration curves from a "databank", there is a one-toone correspondence between the image and the specific compound, and it can be identified accurately both qualitatively and quantitatively. This method offers several significant advantages, and it provides a sensitive (ppm detection level), accurate and simple spectroscopic tool to monitor impurities and pollutants in water. The design and performance of the spectrofluorimeter prototype, as well as the software development and analysis of chemical organic compounds and mixtures in water will be discussed in this paper.

  7. A speeded-up saliency region-based contrast detection method for small targets

    Science.gov (United States)

    Li, Zhengjie; Zhang, Haiying; Bai, Jiaojiao; Zhou, Zhongjun; Zheng, Huihuang

    2018-04-01

    To cope with the rapid development of the real applications for infrared small targets, the researchers have tried their best to pursue more robust detection methods. At present, the contrast measure-based method has become a promising research branch. Following the framework, in this paper, a speeded-up contrast measure scheme is proposed based on the saliency detection and density clustering. First, the saliency region is segmented by saliency detection method, and then, the Multi-scale contrast calculation is carried out on it instead of traversing the whole image. Second, the target with a certain "integrity" property in spatial is exploited to distinguish the target from the isolated noises by density clustering. Finally, the targets are detected by a self-adaptation threshold. Compared with time-consuming MPCM (Multiscale Patch Contrast Map), the time cost of the speeded-up version is within a few seconds. Additional, due to the use of "clustering segmentation", the false alarm caused by heavy noises can be restrained to a lower level. The experiments show that our method has a satisfied FASR (False alarm suppression ratio) and real-time performance compared with the state-of-art algorithms no matter in cloudy sky or sea-sky background.

  8. Laboratory methods for diagnosis and detection of drug resistant ...

    African Journals Online (AJOL)

    Data source: Published series of peer reviewed journals and manuals written on laboratory methods that are currently used for diagnosis and detection of drug resistance of Mycobacterium tuberculosis complex were reviewed using the index medicus, pubmed and medline search. Conventional bacteriological microscopy ...

  9. A review of damage detection methods for wind turbine blades

    International Nuclear Information System (INIS)

    Li, Dongsheng; Song, Gangbing; Ren, Liang; Li, Hongnan; Ho, Siu-Chun M

    2015-01-01

    Wind energy is one of the most important renewable energy sources and many countries are predicted to increase wind energy portion of their whole national energy supply to about twenty percent in the next decade. One potential obstacle in the use of wind turbines to harvest wind energy is the maintenance of the wind turbine blades. The blades are a crucial and costly part of a wind turbine and over their service life can suffer from factors such as material degradation and fatigue, which can limit their effectiveness and safety. Thus, the ability to detect damage in wind turbine blades is of great significance for planning maintenance and continued operation of the wind turbine. This paper presents a review of recent research and development in the field of damage detection for wind turbine blades. Specifically, this paper reviews frequently employed sensors including fiber optic and piezoelectric sensors, and four promising damage detection methods, namely, transmittance function, wave propagation, impedance and vibration based methods. As a note towards the future development trend for wind turbine sensing systems, the necessity for wireless sensing and energy harvesting is briefly presented. Finally, existing problems and promising research efforts for online damage detection of turbine blades are discussed. (topical review)

  10. Local region power spectrum-based unfocused ship detection method in synthetic aperture radar images

    Science.gov (United States)

    Wei, Xiangfei; Wang, Xiaoqing; Chong, Jinsong

    2018-01-01

    Ships on synthetic aperture radar (SAR) images will be severely defocused and their energy will disperse into numerous resolution cells under long SAR integration time. Therefore, the image intensity of ships is weak and sometimes even overwhelmed by sea clutter on SAR image. Consequently, it is hard to detect the ships from SAR intensity images. A ship detection method based on local region power spectrum of SAR complex image is proposed. Although the energies of the ships are dispersed on SAR intensity images, their spectral energies are rather concentrated or will cause the power spectra of local areas of SAR images to deviate from that of sea surface background. Therefore, the key idea of the proposed method is to detect ships via the power spectra distortion of local areas of SAR images. The local region power spectrum of a moving target on SAR image is analyzed and the way to obtain the detection threshold through the probability density function (pdf) of the power spectrum is illustrated. Numerical P- and L-band airborne SAR ocean data are utilized and the detection results are also illustrated. Results show that the proposed method can well detect the unfocused ships, with a detection rate of 93.6% and a false-alarm rate of 8.6%. Moreover, by comparing with some other algorithms, it indicates that the proposed method performs better under long SAR integration time. Finally, the applicability of the proposed method and the way of parameters selection are also discussed.

  11. Comparison of three methods for detection of melamine in compost and soil

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Yongqiang [Depatment of Vegetable Science, College of Agronomy and Biotechnology, China Agricultural University, 2 Yuanmingyuan Xilu, Beijing 100193 (China); School of Environment and Natural Resources, The Ohio State University, 1680 Madison Avenue, Wooster, OH 44691 (United States); Chen, Liming [School of Environment and Natural Resources, The Ohio State University, 1680 Madison Avenue, Wooster, OH 44691 (United States); Gao, Lihong [Depatment of Vegetable Science, College of Agronomy and Biotechnology, China Agricultural University, 2 Yuanmingyuan Xilu, Beijing 100193 (China); Wu, Manli [School of Environment and Natural Resources, The Ohio State University, 1680 Madison Avenue, Wooster, OH 44691 (United States); School of Environmental and Municipal Engineering, Xi' an University of Architecture and Technology, No.13 Yanta Road, Xi' an, Shaanxi Province 710055 (China); Dick, Warren A., E-mail: dick.5@osu.edu [School of Environment and Natural Resources, The Ohio State University, 1680 Madison Avenue, Wooster, OH 44691 (United States)

    2012-02-15

    Recent product recalls and food safety incidents due to melamine (MM) adulteration or contamination have caused a worldwide food security concern. This has led to many methods being developed to detect MM in foods, but few methods haves been reported that can rapidly and reliably measure MM in environmental samples. To meet this need, a high performance liquid chromatography (HPLC) with UV detection method, an enzyme-linked immunosorbent assay (ELISA) test kit, and an enzyme-linked rapid colorimetric assay (RCA) test kit were evaluated for their ability to accurately measure MM concentrations in compost and soil samples. All three methods accurately detected MM concentrations if no MM degradation products, such as ammeline (AMN), ammelide (AMD) and cyanuric acid (CA), were present in an aqueous sample. In the presence of these MM degradation products, the HPLC yielded more accurate concentrations than the ELISA method and there was no significant (P > 0.05) difference between the HPLC and RCA methods. However, if samples were purified by SPE or prepared with blocking buffer, the ELISA method accurately measured MM concentrations, even in the presence of the MM degradation products. The HPLC method generally outperformed the RCA method for measuring MM in soil extracts but gave similar results for compost extracts. The number of samples that can be analyzed by the ELISA and RCA methods in a 24-hour time period is much greater than by the HPLC method. Thus the RCA method would seem to be a good screening method for measuring MM in compost and soil samples and the results obtained could then be confirmed by the HPLC method. The HPLC method, however, also allows simultaneous measurement of MM and its degradation products of AMD, AMN and CA. - Highlights: Black-Right-Pointing-Pointer We detected melamine in environmental samples by three methods. Black-Right-Pointing-Pointer ELISA can measures melamine in an environmental sample if a blocking buffer is used. Black

  12. Time-lag Method for Detecting Following and Leadership Behavior of Pedestrians from Mobile Sensing Data

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Blunck, Henrik; Wüstenberg, Markus

    2013-01-01

    that quantify how humans move, interact and group. In this paper we propose methods for detecting two common pedestrian movement patterns, namely individual following relations and group leadership. The proposed methods for identifying following patterns employ machine learning on features derived using...... similarity analysis on time lagged sequences of WiFi measurements containing either raw signal strength values or derived locations. To detect leadership we combine the individual following relations into directed graphs and detect leadership within groups by graph link analysis. Methods for detecting...... for following patterns and up to twenty percentage points for leadership patterns. Our method is, contrary to state of the art, also applicable in challenging indoor environments, e.g., multi-story buildings. This implies that even quite small samples allow us to detect information such as how events...

  13. Comparison and transfer testing of multiplex ligation detection methods for GM plants

    Directory of Open Access Journals (Sweden)

    Ujhelyi Gabriella

    2012-01-01

    Full Text Available Abstract Background With the increasing number of GMOs on the global market the maintenance of European GMO regulations is becoming more complex. For the analysis of a single food or feed sample it is necessary to assess the sample for the presence of many GMO-targets simultaneously at a sensitive level. Several methods have been published regarding DNA-based multidetection. Multiplex ligation detection methods have been described that use the same basic approach: i hybridisation and ligation of specific probes, ii amplification of the ligated probes and iii detection and identification of the amplified products. Despite they all have this same basis, the published ligation methods differ radically. The present study investigated with real-time PCR whether these different ligation methods have any influence on the performance of the probes. Sensitivity and the specificity of the padlock probes (PLPs with the ligation protocol with the best performance were also tested and the selected method was initially validated in a laboratory exchange study. Results Of the ligation protocols tested in this study, the best results were obtained with the PPLMD I and PPLMD II protocols and no consistent differences between these two protocols were observed. Both protocols are based on padlock probe ligation combined with microarray detection. Twenty PLPs were tested for specificity and the best probes were subjected to further evaluation. Up to 13 targets were detected specifically and simultaneously. During the interlaboratory exchange study similar results were achieved by the two participating institutes (NIB, Slovenia, and RIKILT, the Netherlands. Conclusions From the comparison of ligation protocols it can be concluded that two protocols perform equally well on the basis of the selected set of PLPs. Using the most ideal parameters the multiplicity of one of the methods was tested and 13 targets were successfully and specifically detected. In the

  14. A HYPERSPECTRAL BASED METHOD TO DETECT CANNABIS PLANTATION IN INACCESSIBLE AREAS

    Directory of Open Access Journals (Sweden)

    M. Houmi

    2018-04-01

    Full Text Available The increase in drug use worldwide has led to sophisticated illegal planting methods. Most countries depend on helicopters, and local knowledge to identify such illegal plantations. However, remote sensing techniques can provide special advantages for monitoring the extent of illegal drug production. This paper sought to assess the ability of the Satellite remote sensing to detect Cannabis plantations. This was achieved in two stages: 1- Preprocessing of Hyperspectral data EO-1, and testing the capability to collect the spectral signature of Cannabis in different sites of the study area (Morocco from well-known Cannabis plantation fields. 2- Applying the method of Spectral Angle Mapper (SAM based on a specific angle threshold on Hyperion data EO-1 in well-known Cannabis plantation sites, and other sites with negative Cannabis plantation in another study area (Algeria, to avoid any false Cannabis detection using these spectra. This study emphasizes the benefits of using hyperspectral remote sensing data as an effective detection tool for illegal Cannabis plantation in inaccessible areas based on SAM classification method with a maximum angle (radians less than 0.03.

  15. a Hyperspectral Based Method to Detect Cannabis Plantation in Inaccessible Areas

    Science.gov (United States)

    Houmi, M.; Mohamadi, B.; Balz, T.

    2018-04-01

    The increase in drug use worldwide has led to sophisticated illegal planting methods. Most countries depend on helicopters, and local knowledge to identify such illegal plantations. However, remote sensing techniques can provide special advantages for monitoring the extent of illegal drug production. This paper sought to assess the ability of the Satellite remote sensing to detect Cannabis plantations. This was achieved in two stages: 1- Preprocessing of Hyperspectral data EO-1, and testing the capability to collect the spectral signature of Cannabis in different sites of the study area (Morocco) from well-known Cannabis plantation fields. 2- Applying the method of Spectral Angle Mapper (SAM) based on a specific angle threshold on Hyperion data EO-1 in well-known Cannabis plantation sites, and other sites with negative Cannabis plantation in another study area (Algeria), to avoid any false Cannabis detection using these spectra. This study emphasizes the benefits of using hyperspectral remote sensing data as an effective detection tool for illegal Cannabis plantation in inaccessible areas based on SAM classification method with a maximum angle (radians) less than 0.03.

  16. Detecting Damage in Composite Material Using Nonlinear Elastic Wave Spectroscopy Methods

    Science.gov (United States)

    Meo, Michele; Polimeno, Umberto; Zumpano, Giuseppe

    2008-05-01

    Modern aerospace structures make increasing use of fibre reinforced plastic composites, due to their high specific mechanical properties. However, due to their brittleness, low velocity impact can cause delaminations beneath the surface, while the surface may appear to be undamaged upon visual inspection. Such damage is called barely visible impact damage (BVID). Such internal damages lead to significant reduction in local strengths and ultimately could lead to catastrophic failures. It is therefore important to detect and monitor damages in high loaded composite components to receive an early warning for a well timed maintenance of the aircraft. Non-linear ultrasonic spectroscopy methods are promising damage detection and material characterization tools. In this paper, two different non-linear elastic wave spectroscopy (NEWS) methods are presented: single mode nonlinear resonance ultrasound (NRUS) and nonlinear wave modulation technique (NWMS). The NEWS methods were applied to detect delamination damage due to low velocity impact (<12 J) on various composite plates. The results showed that the proposed methodology appear to be highly sensitive to the presence of damage with very promising future NDT and structural health monitoring applications.

  17. Non-invasive method for in vivo detection of chlorophyll precursors

    DEFF Research Database (Denmark)

    Kristiansen, Kim Anker; Khrouchtchova, Anastassia; Stenbæk, Anne

    2009-01-01

    Traditionally chlorophyll (Chl) and Chl precursors have been studied in vitro or in leaf tissue at low temperature. These methods are destructive and make it impossible to work with the same individual plant later on. In this paper we present a method for in vivo detection of Chl and its precursors...... is compared to current methods. Furthermore, we report on optimization of the spectral scanning method with the aim to minimize the excitation light-evoked photo-conversion of the chlorophyll precursors....

  18. New Vehicle Detection Method with Aspect Ratio Estimation for Hypothesized Windows

    Directory of Open Access Journals (Sweden)

    Jisu Kim

    2015-12-01

    Full Text Available All kinds of vehicles have different ratios of width to height, which are called the aspect ratios. Most previous works, however, use a fixed aspect ratio for vehicle detection (VD. The use of a fixed vehicle aspect ratio for VD degrades the performance. Thus, the estimation of a vehicle aspect ratio is an important part of robust VD. Taking this idea into account, a new on-road vehicle detection system is proposed in this paper. The proposed method estimates the aspect ratio of the hypothesized windows to improve the VD performance. Our proposed method uses an Aggregate Channel Feature (ACF and a support vector machine (SVM to verify the hypothesized windows with the estimated aspect ratio. The contribution of this paper is threefold. First, the estimation of vehicle aspect ratio is inserted between the HG (hypothesis generation and the HV (hypothesis verification. Second, a simple HG method named a signed horizontal edge map is proposed to speed up VD. Third, a new measure is proposed to represent the overlapping ratio between the ground truth and the detection results. This new measure is used to show that the proposed method is better than previous works in terms of robust VD. Finally, the Pittsburgh dataset is used to verify the performance of the proposed method.

  19. Detection of protozoa in water samples by formalin/ether concentration method.

    Science.gov (United States)

    Lora-Suarez, Fabiana; Rivera, Raul; Triviño-Valencia, Jessica; Gomez-Marin, Jorge E

    2016-09-01

    Methods to detect protozoa in water samples are expensive and laborious. We evaluated the formalin/ether concentration method to detect Giardia sp., Cryptosporidium sp. and Toxoplasma in water. In order to test the properties of the method, we spiked water samples with different amounts of each protozoa (0, 10 and 50 cysts or oocysts) in a volume of 10 L of water. Immunofluorescence assay was used for detection of Giardia and Cryptosporidium. Toxoplasma oocysts were identified by morphology. The mean percent of recovery in 10 repetitions of the entire method, in 10 samples spiked with ten parasites and read by three different observers, were for Cryptosporidium 71.3 ± 12, for Giardia 63 ± 10 and for Toxoplasma 91.6 ± 9 and the relative standard deviation of the method was of 17.5, 17.2 and 9.8, respectively. Intraobserver variation as measured by intraclass correlation coefficient, was fair for Toxoplasma, moderate for Cryptosporidium and almost perfect for Giardia. The method was then applied in 77 samples of raw and drinkable water in three different plant of water treatment. Cryptosporidium was found in 28 of 77 samples (36%) and Giardia in 31 of 77 samples (40%). Theses results identified significant differences in treatment process to reduce the presence of Giardia and Cryptosporidium. In conclusion, the formalin ether method to concentrate protozoa in water is a new alternative for low resources countries, where is urgently need to monitor and follow the presence of theses protozoa in drinkable water. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Methods of Run-Time Error Detection in Distributed Process Control Software

    DEFF Research Database (Denmark)

    Drejer, N.

    of generic run-time error types, design of methods of observing application software behaviorduring execution and design of methods of evaluating run time constraints. In the definition of error types it is attempted to cover all relevant aspects of the application softwaree behavior. Methods of observation......In this thesis, methods of run-time error detection in application software for distributed process control is designed. The error detection is based upon a monitoring approach in which application software is monitored by system software during the entire execution. The thesis includes definition...... and constraint evaluation is designed for the modt interesting error types. These include: a) semantical errors in data communicated between application tasks; b) errors in the execution of application tasks; and c) errors in the timing of distributed events emitted by the application software. The design...

  1. Bioanalytical methods for food allergy diagnosis, allergen detection and new allergen discovery

    OpenAIRE

    Gasilova, Natalia; Girault, Hubert H

    2015-01-01

    For effective monitoring and prevention of the food allergy, one of the emerging health problems nowadays, existing diagnostic procedures and allergen detection techniques are constantly improved. Meanwhile, new methods are also developed, and more and more putative allergens are discovered. This review describes traditional methods and summarizes recent advances in the fast evolving field of the in vitro food allergy diagnosis, allergen detection in food products and discovery of the new all...

  2. Method to detect biological particles

    International Nuclear Information System (INIS)

    Giaever, I.

    1976-01-01

    A medical-diagnostic method to detect immunological as well as other specific reactions is described. According to the invention, first reactive particles (e.g. antibodies) are adsorbed on the surface of a solid, non-reactive substrate. The coated substrate is subjected to a solution which one assumes to contain the second biological particles (e.g. antigens) which are specific to the first and form complexes with these. A preferential radioactive labelling (e.g. with iodine 125) of the second biological particle is then directly or indirectly carried out. Clearage follows labelling in order to separate the second biological particles from the first ones. A specific splitting agent can selectively break the bond of both types of particle. The splitting agent solution is finally separated off and its content is investigated for the presence of labelling. (VJ) [de

  3. Comparison of Bayesian clustering and edge detection methods for inferring boundaries in landscape genetics

    Science.gov (United States)

    Safner, T.; Miller, M.P.; McRae, B.H.; Fortin, M.-J.; Manel, S.

    2011-01-01

    Recently, techniques available for identifying clusters of individuals or boundaries between clusters using genetic data from natural populations have expanded rapidly. Consequently, there is a need to evaluate these different techniques. We used spatially-explicit simulation models to compare three spatial Bayesian clustering programs and two edge detection methods. Spatially-structured populations were simulated where a continuous population was subdivided by barriers. We evaluated the ability of each method to correctly identify boundary locations while varying: (i) time after divergence, (ii) strength of isolation by distance, (iii) level of genetic diversity, and (iv) amount of gene flow across barriers. To further evaluate the methods' effectiveness to detect genetic clusters in natural populations, we used previously published data on North American pumas and a European shrub. Our results show that with simulated and empirical data, the Bayesian spatial clustering algorithms outperformed direct edge detection methods. All methods incorrectly detected boundaries in the presence of strong patterns of isolation by distance. Based on this finding, we support the application of Bayesian spatial clustering algorithms for boundary detection in empirical datasets, with necessary tests for the influence of isolation by distance. ?? 2011 by the authors; licensee MDPI, Basel, Switzerland.

  4. Weak wide-band signal detection method based on small-scale periodic state of Duffing oscillator

    Science.gov (United States)

    Hou, Jian; Yan, Xiao-peng; Li, Ping; Hao, Xin-hong

    2018-03-01

    The conventional Duffing oscillator weak signal detection method, which is based on a strong reference signal, has inherent deficiencies. To address these issues, the characteristics of the Duffing oscillatorʼs phase trajectory in a small-scale periodic state are analyzed by introducing the theory of stopping oscillation system. Based on this approach, a novel Duffing oscillator weak wide-band signal detection method is proposed. In this novel method, the reference signal is discarded, and the to-be-detected signal is directly used as a driving force. By calculating the cosine function of a phase space angle, a single Duffing oscillator can be used for weak wide-band signal detection instead of an array of uncoupled Duffing oscillators. Simulation results indicate that, compared with the conventional Duffing oscillator detection method, this approach performs better in frequency detection intervals, and reduces the signal-to-noise ratio detection threshold, while improving the real-time performance of the system. Project supported by the National Natural Science Foundation of China (Grant No. 61673066).

  5. Evaluation of different methods to detect methicillin resistance in Staphylococcus aureus (MRSA).

    Science.gov (United States)

    Alipour, Farzad; Ahmadi, Malahat; Javadi, Shahram

    2014-01-01

    The studies suggest that dogs living with human are potential risk of becoming MRSA carrier and increased risk of infections caused by MRSA. Phenotypic methods to detect methicillin resistance in Staphylococcus aureus (MRSA) are inadequate. The objective of the present study was to determine methicillin resistance in S. aureus by phenotypic susceptibility test (oxacillin disk diffusion, cefoxitin disk diffusion, oxacillin screen agar) and molecular methods (PCR as a gold standard) and the latex agglutination test for the detection of PBP2a and to evaluate the results of these tests for its sensitivity and specificity. A total of 100 swab samples were taken from muzzle site, in more contact with human, of dogs and MRSA were isolated. Oxacillin (1 μg), cefoxitin (30 μg) disk diffusion and oxacillin screen agar method were used. The isolates were also subjected to latex agglutination test for detection of PBP2a and PCR to detect mecA gene. By PCR 37% of isolates show the presence of mecA. Latex agglutination was found to be the most sensitive (97.29%) and cefoxitin disk diffusion to be the most specific (96.82%) tests for detection of MRSA. Our finding showed that combining oxacillin screen agar or cefoxitin disk diffusion with latex agglutination improves sensitivity and specificity to detect methicillin resistance S. aureus (MRSA) isolates. Copyright © 2014 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  6. Effects of Feature Extraction and Classification Methods on Cyberbully Detection

    OpenAIRE

    ÖZEL, Selma Ayşe; SARAÇ, Esra

    2016-01-01

    Cyberbullying is defined as an aggressive, intentional action against a defenseless person by using the Internet, or other electronic contents. Researchers have found that many of the bullying cases have tragically ended in suicides; hence automatic detection of cyberbullying has become important. In this study we show the effects of feature extraction, feature selection, and classification methods that are used, on the performance of automatic detection of cyberbullying. To perform the exper...

  7. Rapid detection of new and expanding human settlements in the Limpopo province of South Africa using a spatio-temporal change detection method

    Science.gov (United States)

    Kleynhans, W.; Salmon, B. P.; Wessels, K. J.; Olivier, J. C.

    2015-08-01

    Recent development has identified the benefits of using hyper-temporal satellite time series data for land cover change detection and classification in South Africa. In particular, the monitoring of human settlement expansion in the Limpopo province is of relevance as it is the one of the most pervasive forms of land-cover change in this province which covers an area of roughly 125 000 km2. In this paper, a spatio-temporal autocorrelation change detection (STACD) method is developed to improve the performance of a pixel based temporal Autocorrelation change detection (TACD) method previously proposed. The objective is to apply the algorithm to large areas to detect the conversion of natural vegetation to settlement which is then validated by an operator using additional data (such as high resolution imagery). Importantly, as the objective of the method is to indicate areas of potential change to operators for further analysis, a low false alarm rate is required while achieving an acceptable probability of detection. Results indicate that detection accuracies of 70% of new settlement instances are achievable at a false alarm rate of less than 1% with the STACD method, an improvement of up to 17% compared to the original TACD formulation.

  8. Vibration-Based Adaptive Novelty Detection Method for Monitoring Faults in a Kinematic Chain

    Directory of Open Access Journals (Sweden)

    Jesus Adolfo Cariño-Corrales

    2016-01-01

    Full Text Available This paper presents an adaptive novelty detection methodology applied to a kinematic chain for the monitoring of faults. The proposed approach has the premise that only information of the healthy operation of the machine is initially available and fault scenarios will eventually develop. This approach aims to cover some of the challenges presented when condition monitoring is applied under a continuous learning framework. The structure of the method is divided into two recursive stages: first, an offline stage for initialization and retraining of the feature reduction and novelty detection modules and, second, an online monitoring stage to continuously assess the condition of the machine. Contrary to classical static feature reduction approaches, the proposed method reformulates the features by employing first a Laplacian Score ranking and then the Fisher Score ranking for retraining. The proposed methodology is validated experimentally by monitoring the vibration measurements of a kinematic chain driven by an induction motor. Two faults are induced in the motor to validate the method performance to detect anomalies and adapt the feature reduction and novelty detection modules to the new information. The obtained results show the advantages of employing an adaptive approach for novelty detection and feature reduction making the proposed method suitable for industrial machinery diagnosis applications.

  9. The MIMIC Method with Scale Purification for Detecting Differential Item Functioning

    Science.gov (United States)

    Wang, Wen-Chung; Shih, Ching-Lin; Yang, Chih-Chien

    2009-01-01

    This study implements a scale purification procedure onto the standard MIMIC method for differential item functioning (DIF) detection and assesses its performance through a series of simulations. It is found that the MIMIC method with scale purification (denoted as M-SP) outperforms the standard MIMIC method (denoted as M-ST) in controlling…

  10. Real-time method for establishing a detection map for a network of sensors

    Science.gov (United States)

    Nguyen, Hung D; Koch, Mark W; Giron, Casey; Rondeau, Daniel M; Russell, John L

    2012-09-11

    A method for establishing a detection map of a dynamically configurable sensor network. This method determines an appropriate set of locations for a plurality of sensor units of a sensor network and establishes a detection map for the network of sensors while the network is being set up; the detection map includes the effects of the local terrain and individual sensor performance. Sensor performance is characterized during the placement of the sensor units, which enables dynamic adjustment or reconfiguration of the placement of individual elements of the sensor network during network set-up to accommodate variations in local terrain and individual sensor performance. The reconfiguration of the network during initial set-up to accommodate deviations from idealized individual sensor detection zones improves the effectiveness of the sensor network in detecting activities at a detection perimeter and can provide the desired sensor coverage of an area while minimizing unintentional gaps in coverage.

  11. Microfluidic platform for multiplexed detection in single cells and methods thereof

    Science.gov (United States)

    Wu, Meiye; Singh, Anup K.

    2018-05-01

    The present invention relates to a microfluidic device and platform configured to conduct multiplexed analysis within the device. In particular, the device allows multiple targets to be detected on a single-cell level. Also provided are methods of performing multiplexed analyses to detect one or more target nucleic acids, proteins, and post-translational modifications.

  12. Comparison of thermoluminescence detection methods for irradiated spices

    International Nuclear Information System (INIS)

    Kawamura, Y.; Murayama, M.; Uchiyama, S.; Saito, Y.

    1996-01-01

    Thermoluminescence (TL) analysis has been shown to be one of the most applicable methods for the detection of γ-irradiated spices. This analysis was introduced as a detection technique for irradiated spices using the whole sample. It was then found that the origin of the TL response to be mineral dust adhering to the spices. TL measurements on separated minerals and the normalised TL measurement by re-irradiation was then established. This paper details investigations on TL measurements carried out using clean powdered spices stored for one year after being irradiated with doses of 1, 5, 10 and 30 kGy in order to clarify their applicable dose range, the effect of storage and mineral content. The effect of the mineral separation was also studied. (author)

  13. Effect of Multi-condition Training and Speech Enhancement Methods on Spoofing Detection

    DEFF Research Database (Denmark)

    Yu, Hong; Sarkar, Achintya Kumar; Thomsen, Dennis Alexander Lehmann

    2016-01-01

    enhancement methods on a state of-the-art spoofing detection system based on the dynamic linear frequency cepstral coefficients (LFCC) feature and a Gaussian mixture model maximum-likelihood (GMM-ML) classifier. In the experiment part we consider three additive noise types, Cantine, Babble and white Gaussian......Many researchers have demonstrated the good performance of spoofing detection systems under clean training and testing conditions. However, it is well known that the performance of speaker and speech recognition systems significantly degrades in noisy conditions. Therefore, it is of great interest...... to investigate the effect of noise on the performance of spoofing detection systems. In this paper, we investigate a multi-conditional training method where spoofing detection models are trained with a mix of clean and noisy data. In addition, we study the effect of different noise types as well as speech...

  14. Discrete Data Qualification System and Method Comprising Noise Series Fault Detection

    Science.gov (United States)

    Fulton, Christopher; Wong, Edmond; Melcher, Kevin; Bickford, Randall

    2013-01-01

    A Sensor Data Qualification (SDQ) function has been developed that allows the onboard flight computers on NASA s launch vehicles to determine the validity of sensor data to ensure that critical safety and operational decisions are not based on faulty sensor data. This SDQ function includes a novel noise series fault detection algorithm for qualification of the output data from LO2 and LH2 low-level liquid sensors. These sensors are positioned in a launch vehicle s propellant tanks in order to detect propellant depletion during a rocket engine s boost operating phase. This detection capability can prevent the catastrophic situation where the engine operates without propellant. The output from each LO2 and LH2 low-level liquid sensor is a discrete valued signal that is expected to be in either of two states, depending on whether the sensor is immersed (wet) or exposed (dry). Conventional methods for sensor data qualification, such as threshold limit checking, are not effective for this type of signal due to its discrete binary-state nature. To address this data qualification challenge, a noise computation and evaluation method, also known as a noise fault detector, was developed to detect unreasonable statistical characteristics in the discrete data stream. The method operates on a time series of discrete data observations over a moving window of data points and performs a continuous examination of the resulting observation stream to identify the presence of anomalous characteristics. If the method determines the existence of anomalous results, the data from the sensor is disqualified for use by other monitoring or control functions.

  15. Comparison of two detection methods in thin layer chromatographic ...

    African Journals Online (AJOL)

    o-tolidine plus potassium iodide and photosynthesis inhibition detection methods were investigated for the analysis of three triazine herbicides (atrazine, ametryne, simazine) and two urea herbicides (diuron, metobromuron) in a coastal savanna soil using thin layer chromatography to compare the suitability of the two ...

  16. Detection and localization of leak of pipelines of RBMK reactor. Methods of processing of acoustic noise

    International Nuclear Information System (INIS)

    Tcherkaschov, Y.M.; Strelkov, B.P.; Chimanski, S.B.; Lebedev, V.I.; Belyanin, L.A.

    1997-01-01

    For realization of leak detection of input pipelines and output pipelines of RBMK reactor the method, based on detection and control of acoustic leak signals, was designed. In this report the review of methods of processing and analysis of acoustic noise is submitted. These methods were included in the software of the leak detection system and are used for the decision of the following problems: leak detection by method of sound pressure level in conditions of powerful background noise and strong attenuation of a signal; detection of a small leak in early stage by high-sensitivity correlation method; determination of a point of a sound source in conditions of strong reflection of a signal by a correlation method and sound pressure method; evaluation of leak size by the analysis of a sound level and point of a sound source. The work of considered techniques is illustrated on an example of test results of a fragment of the leak detection system. This test was executed on a Leningrad NPP, operated at power levels of 460, 700, 890 and 1000 MWe. 16 figs

  17. SCREENING METHODS FOR THE DETECTION OF CARTELS

    Directory of Open Access Journals (Sweden)

    Mihail BUŞU

    2014-06-01

    Full Text Available During their everyday activities, the economic operators conclude a multitude of agreements in tacit or written form, such as: contracts or conventions. Some of these arrangements are absolutely necessary for the development of their current activities. These are agreements which, by respecting the rules of competition, are able to bring benefits to consumers and to the entire economy, as a whole. On the other hand, the economic operators often conclude agreements which are harmful to the economy as well as to the consumers, violating the competition rules. Some examples in this respect are: operators’ agreements on price fixing, on market or customers sharing. Before investigating the violation of competition rules, the relevant authorities should identify the possibility of the existence of such illegalities. The theoretical models for detecting the cartels do represent a proactive tool concerning the antitrust activity of competition authorities. The present paper furnishes a review of the methods for detecting cartels as well as a part of their practical application.

  18. Development of genetic methods for detection of pathogenic microorganisms in irradiated food

    International Nuclear Information System (INIS)

    2010-01-01

    The existence of injured microorganisms in food and their recovery during culturing procedures is critical. Injured microorganisms present a potential threat in food safety since they may repair themselves under suitable conditions. This study provides development of recovery methods for detection of injured foodborne microorganisms, after irradiation treatment at different doses. For this purpose, iniatially the methods of recovery were compared at different irradiation doses. At the second step, antibiotic resistance of foodborne pathogens was determined. After determination of antibiotic resistance, recovery methods were modified for reversibly injured foodborne pathogens at different doses after irradiation treatment . Finally, damages of DNA were detected by a spectrophotometric method after 1.0 kGy irradiation treatment

  19. Drop weight impact measurements of HE sensitivity: modified detection methods

    International Nuclear Information System (INIS)

    Preston, D N; Brown, G W; Tappan, B C; Oshwald, D M; Koby, J R; Schoonover, M L

    2014-01-01

    High explosives small-scale sensitivity testing has been a hallmark of safety screening since WWII. Sensitivity testing was once crude and simple; broom sticks were used to scrape explosives on the floor while experimenters would look, listen, and smell for signs of a reaction. Since then, a wide variety of testing apparatus have been developed to explore the effects of different stimuli on explosives. In concert with the development of the machines themselves, the reaction detection methods have also evolved. This paper's focus is on the Los Alamos National Laboratory's (LANL) drop weight impact machine and reaction detection methods. A critical evaluation of results is presented with cautionary examples of false positives that can occur with non-explosive materials.

  20. Problems of detection method of coronary arterial stenosis on cineangiograms by computer image processing

    International Nuclear Information System (INIS)

    Sugahara, Tetsuo; Yanagihara, Yoshio; Sugimoto, Naozou; Uyama, Chikao; Maeda, Hirofumi.

    1988-01-01

    For the evaluation of the coronary arterial stenosis (CAS), the detection method of CAS were estimated on the coronary cineangiograms by computer image processing. For correlation of the accuracy of measurement of diameter on the image of resolution of 30 and 4 μm/pixel were measured the diameter on the vessel model images using sum of first and second differential method. The accuracy of measurement on resolution image of 30 and 4 μm/pixel on 3 mm diameter is 4.7 % and 2.3 %, respectively. Threshold method was used for the detection of the arterial wall on the subtraction images. For the detection of CAS, measurement method of the branch segment and determination method of the radius and normal vessel diameter were evaluated. A matter of special importance is determination method of the normal diameter. In view of the fact that this is a matter of great importance, it caused error to the measurement of prerent stenosis and stenotic length. This resulted that the detection of CAS was important not only the accuracy of measurement of the vessel diameter but also determination method of the normal diameter. (author)