WorldWideScience

Sample records for helium ions anwendung

  1. Application of the in-beam PET therapy monitoring on precision irradiations with helium ions; Anwendung des in-beam PET Therapiemonitorings auf Praezisionsbestrahlungen mit Helium-Ionen

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, F.

    2008-02-19

    The main goal of the present dissertation was to extend the in-beam PET method to new ion types. It was shown that the in-beam PET method can also be applied for {sup 3}He irradiations. For this experiments on a {sup 3}He beam were performed. The activity yield is at equal applied dose about three times larger than at {sup 12}C irradiations. The reachable range resolution is smaller than 1 mm. At the irradiation of an inhomogeneous phantom it was shown that a contrast between different materials is resolvable. From the experimentally determined reaction rates cross sections for the reactions leading to positron emitters were performed. The data taken in the {sup 3}He experiments were compared those obtained in carbon-ion experiments as well as literature data for proton irradiations. A comparison with the calculations of the simulation program SHIELD-HIT was performed. A collection of cross-section models and the established requirements for a simulation program applicable for in-beam PET are preparing for further work.

  2. Nanofabrication with a helium ion microscope

    NARCIS (Netherlands)

    Maas, D.; Van Veldhoven, E.; Chen, P.; Sidorkin, V.; Salemink, H.; Van der Drift, E.; Alkemade, P.

    2009-01-01

    The recently introduced helium ion microscope (HIM) is capable of imaging and fabrication of nanostructures thanks to its sub-nanometer sized ion probe [1,2]. The unique interaction of the helium ions with the sample material provides very localized secondary electron emission, thus providing a

  3. Radioactive ions and atoms in superfluid helium

    NARCIS (Netherlands)

    Dendooven, P.G.; Purushothaman, S.; Gloos, K.; Aysto, J.; Takahashi, N.; Huang, W.; Harissopulos, S; Demetriou, P; Julin, R

    2006-01-01

    We are investigating the use of superfluid helium as a medium to handle and manipulate radioactive ions and atoms. Preliminary results on the extraction of positive ions from superfluid helium at temperatures close to 1 K are described. Increasing the electric field up to 1.2 kV/cm did not improve

  4. Backscattered Helium Spectroscopy in the Helium Ion Microscope: Principles, Resolution and Applications

    NARCIS (Netherlands)

    van Gastel, Raoul; Hlawacek, G.; Dutta, S.; Poelsema, Bene

    2015-01-01

    We demonstrate the possibilities and limitations for microstructure characterization using backscattered particles from a sharply focused helium ion beam. The interaction of helium ions with matter enables the imaging, spectroscopic characterization, as well as the nanometer scale modification of

  5. Quantum entanglement in helium-like ions

    Science.gov (United States)

    Lin, Y.-C.; Ho, Y. K.

    2012-06-01

    Recently, there have been considerable interests to investigate quantum entanglement in two-electron atoms [1-3]. Here we investigate quantum entanglement for the ground and excited states of helium-like ions using correlated wave functions, concentrating on the particle-particle entanglement coming from the continuous spatial degrees of freedom. We use the two-electron wave functions constructed by employing B-spline basis to calculate the linear entropy of the reduced density matrix L=1-TrA(ρA^2 ) as a measure of the spatial entanglement. HereρA=TrB(| >AB ABDehesa et. al., J. Phys. B 45, 015504 (2012)

  6. Nano-engineering with a focused helium ion beam

    NARCIS (Netherlands)

    Maas, D.J.; Drift, E.W. van der; Veldhoven, E. van; Meessen, J.; Rudneva, M.; Alkemade, P.F.A.

    2011-01-01

    Although Helium Ion Microscopy (HIM) was introduced only a few years ago, many new application fields are budding. The connecting factor between these novel applications is the unique interaction of the primary helium ion beam with the sample material at and just below its surface. In particular,

  7. Deposition, milling, and etching with a focused helium ion beam

    NARCIS (Netherlands)

    Alkemade, P.F.A.; Veldhoven, E. van

    2012-01-01

    The recent successful development of the helium ion microscope has produced both a new type of microscopy and a new tool for nanoscale manufacturing. This chapter reviews the first explorations in this new field in nanofabrication. The studies that utilize the Orion helium ion microscope to grow or

  8. Transport and extraction of radioactive ions stopped in superfluid helium

    CERN Document Server

    Huang Wan Xia; Gloos, K; Takahashi, N; Arutyunov, K; Pekola, J P; Äystö, J

    2003-01-01

    A new approach to convert a high energy beam to a low energy one, which is essential for the next generation radioactive ion beam facilities, has been proposed and tested at Jyvaeskylae, Finland. An open sup 2 sup 2 sup 3 Ra alpha-decay-recoil source has been used to produce radioactive ions in superfluid helium. The alpha spectra demonstrate that the recoiling sup 2 sup 1 sup 9 Rn ions have been extracted out of liquid helium. This first observation of the extraction of heavy positive ions across the superfluid helium surface was possible thanks to the high sensitivity of radioactivity detection. An efficiency of 36% was obtained for the ion extraction out of liquid helium.

  9. HEATHER - HElium Ion Accelerator for RadioTHERapy

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Jordan [Huddersfield U.; Edgecock, Thomas [Huddersfield U.; Green, Stuart [Birmingham U.; Johnstone, Carol [Fermilab

    2017-05-01

    A non-scaling fixed field alternating gradient (nsFFAG) accelerator is being designed for helium ion therapy. This facility will consist of 2 superconducting rings, treating with helium ions (He²⁺ ) and image with hydrogen ions (H + 2 ). Currently only carbon ions are used to treat cancer, yet there is an increasing interest in the use of lighter ions for therapy. Lighter ions have reduced dose tail beyond the tumour compared to carbon, caused by low Z secondary particles produced via inelastic nuclear reactions. An FFAG approach for helium therapy has never been previously considered. Having demonstrated isochronous acceleration from 0.5 MeV to 900 MeV, we now demonstrate the survival of a realistic beam across both stages.

  10. Scanning reflection ion microscopy in a helium ion microscope

    Directory of Open Access Journals (Sweden)

    Yuri V. Petrov

    2015-05-01

    Full Text Available Reflection ion microscopy (RIM is a technique that uses a low angle of incidence and scattered ions to form an image of the specimen surface. This paper reports on the development of the instrumentation and the analysis of the capabilities and limitations of the scanning RIM in a helium ion microscope (HIM. The reflected ions were detected by their “conversion” to secondary electrons on a platinum surface. An angle of incidence in the range 5–10° was used in the experimental setup. It was shown that the RIM image contrast was determined mostly by surface morphology but not by the atomic composition. A simple geometrical analysis of the reflection process was performed together with a Monte Carlo simulation of the angular dependence of the reflected ion yield. An interpretation of the RIM image formation and a quantification of the height of the surface steps were performed. The minimum detectable step height was found to be approximately 5 nm. RIM imaging of an insulator surface without the need for charge compensation was successfully demonstrated.

  11. Radioactive core ions of microclusters, ``snowballs`` in superfluid helium

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, N. [Osaka Univ., Toyonaka (Japan). Dept. of Physics; Shimoda, T. [Osaka Univ., Toyonaka (Japan). Dept. of Physics; Fujita, Y. [Osaka Univ., Toyonaka (Japan). Dept. of Physics; Miyatake, H. [Osaka Univ., Toyonaka (Japan). Dept. of Physics; Mizoi, Y. [Osaka Univ., Toyonaka (Japan). Dept. of Physics; Kobayashi, H. [Osaka Univ., Toyonaka (Japan). Dept. of Physics; Sasaki, M. [Osaka Univ., Toyonaka (Japan). Dept. of Physics; Shirakura, T. [Osaka Univ., Toyonaka (Japan). Dept. of Physics; Itahashi, T. [Research Center for Nuclear Physics, Osaka Univ., Ibaraki (Japan); Mitsuoka, S. [Research Center for Nuclear Physics, Osaka Univ., Ibaraki (Japan); Matsukawa, T. [Naruto Univ. of Education, Tokushima (Japan); Ikeda, N. [Kyushu Univ., Fukuoka (Japan). Dept. of Physics; Morinobu, S. [Kyushu Univ., Fukuoka (Japan). Dept. of Physics; Hinde, D.J. [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences; Asahi, K. [Tokyo Inst. of Tech. (Japan). Dept. of Physics; Ueno, H. [Tokyo Inst. of Tech. (Japan). Dept. of Physics; Izumi, H. [Tokyo Inst. of Tech. (Japan). Dept. of Physics

    1996-12-01

    Short-lived beta-ray emitters, {sup 12}B, sustaining nuclear spin polarization were introduced into superfluid helium. The nuclear polarization of {sup 12}B was observed via measurement of beta-ray asymmetry. It was found that the nuclear polarization was preserved throughout the lifetime of {sup 12}B (20.3 ms). This suggests that the ``snowball``, an aggregation of helium atoms produced around an alien ion, constitutes a suitable milieu for freezing-out the nuclear spin of the core ion and that most likely the solidification takes place at the interior of the aggregation. (orig.).

  12. Conductivity change of defective graphene by helium ion beams

    Directory of Open Access Journals (Sweden)

    Yuichi Naitou

    2017-04-01

    Full Text Available Applying a recently developed helium ion microscope, we demonstrated direct nano-patterning and Anderson localization of single-layer graphene (SLG on SiO2/Si substrates. In this study, we clarified the spatial-resolution-limitation factor of direct nano-patterning of SLG. Analysis of scanning capacitance microscopy measurements reveals that the conductivity of helium ion (H+-irradiated SLG nanostructures depends on their geometrical size, i.e., the smaller the H+-irradiated SLG region, the higher its conductivity becomes. This finding can be explained by the hopping carrier transport across strongly localized states of defective SLG.

  13. IR spectroscopy of molecular ions by nonthermal ion ejection from helium nanodroplets.

    Science.gov (United States)

    Smolarek, Szymon; Brauer, Nils B; Buma, Wybren J; Drabbels, Marcel

    2010-10-13

    Infrared spectroscopy provides a means to determine the intrinsic geometrical structures of molecules. Here we present a novel spectroscopic method that uses superfluid helium nanodroplets to record IR spectra of cold molecular ions, in this particular case aniline cations. The method is based on the detection of ions that are ejected from the helium droplets following vibrational excitation of these ions. We find that spectra can be recorded with a high sensitivity and that they exhibit only a small matrix shift. The widths of the individual transitions depend on the excited vibrational level and are thought to be related to the interaction of the ion with the surrounding helium solvent shells.

  14. Development and application of ion beam diagnostics; Entwicklung und Anwendung schneller Strahldiagnose fuer Ionenstrahlen

    Energy Technology Data Exchange (ETDEWEB)

    Pfister, Jochen

    2010-06-07

    At GSI - Helmholtz Centre for Heavy Ion Research in Darmstadt/Germany the HITRAP project is in the commissioning phase. This world-wide unique facility consists of a linear decelerator for heavy, highly charged ions including atomic physics precision experiments. During commissioning of the cavities, transverse emittances were measured using the single-shot pepperpot method as well as the multi-gradient method. The extraction emittance of the experimental storage ring (ESR) was determined. Furthermore, the phase space distribution of an decelerated beam at an intermediate energy of 500keV/u was measured behind the IH-structure. New algorithms have been integrated into the analysis of digital images. The longitudinal bunch structure measurements of the ion beam at the entry point into the decelerator and the operation of the Double-drift Buncher is shown. The design, development and the first commissioning of a new single-shot pepperpot emittance meter for very low beam currents and beam energies in the order of some hundred nA is described, making it possible to measure the beam behind the deceleration cavities. In addition, transverse beam dynamics calculations were performed, which supported the hands-on commissioning of the accelerator. It is described how the entire beam line from the ESR to the radio-frequency quadrupole can be optimized using the new routine for transverse effects of the bunching and deceleration, which was successfully integrated into the software COSY Infinity. (orig.)

  15. Sputtering of solid nitrogen by keV helium ions

    DEFF Research Database (Denmark)

    Ellegaard, O.; Schou, Jørgen; Sørensen, H.

    1993-01-01

    Solid nitrogen has become a standard material among the frozen molecular gases for electronic sputtering. We have combined measurements of sputtering yields and energy spectra from nitrogen bombarded by 4-10 keV helium ions. The data show that the erosion is electronic rather than knockon...

  16. The Erosion of Frozen Argon by Swift Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Graversen, O.

    1981-01-01

    The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore...

  17. The Helium Atom and Isoelectronic Ions in Two Dimensions

    Science.gov (United States)

    Patil, S. H.

    2008-01-01

    The energy levels of the helium atom and isoelectronic ions in two dimensions are considered. The difficulties encountered in the analytical evaluation of the perturbative and variational expressions for the ground state, promote an interesting factorization of the inter-electronic interaction, leading to simple expressions for the energy. This…

  18. Subsurface analysis of semiconductor structures with helium ion microscopy

    NARCIS (Netherlands)

    van Gastel, Raoul; Hlawacek, G.; Zandvliet, Henricus J.W.; Poelsema, Bene

    2012-01-01

    We have used helium ion microscopy to directly track the subsurface diffusion of Pd through a Si stack in a non-invasive manner. The imaging and analysis of semiconductor structures along a direction perpendicular to the substrate is traditionally performed by making cross sections of a sample and

  19. Investigation of Cellular Interactions of Nanoparticles by Helium Ion Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Arey, Bruce W.; Shutthanandan, V.; Xie, Yumei; Tolic, Ana; Williams, Nolann G.; Orr, Galya

    2011-06-01

    The helium ion mircroscope (HIM) probes light elements (e.g. C, N, O, P) with high contrast due to the large variation in secondary electron yield, which minimizes the necessity of specimen staining. A defining characteristic of HIM is its remarkable capability to neutralize charge by the implementation of an electron flood gun, which eliminates the need for coating non-conductive specimens for imaging at high resolution. In addition, the small convergence angle in HeIM offers a large depth of field (~5x FE-SEM), enabling tall structures to be viewed in focus within a single image. Taking advantage of these capabilities, we investigate the interactions of engineered nanoparticles (NPs) at the surface of alveolar type II epithelial cells grown at the air-liquid interface (ALI). The increasing use of nanomaterials in a wide range of commercial applications has the potential to increase human exposure to these materials, but the impact of such exposure on human health is still unclear. One of the main routs of exposure is the respiratory tract, where alveolar epithelial cells present a vulnerable target at the interface with ambient air. Since the cellular interactions of NPs govern the cellular response and ultimately determine the impact on human health, our studies will help delineating relationships between particle properties and cellular interactions and response to better evaluate NP toxicity or biocompatibility. The Rutherford backscattered ion (RBI) is a helium ions imaging mode, which backscatters helium ions from every element except hydrogen, with a backscatter yield that depends on the atomic number of the target. Energy-sensitive backscatter analysis is being developed, which when combined with RBI image information, supports elemental identification at helium ion nanometer resolution. This capability will enable distinguishing NPs from cell surface structures with nanometer resolution.

  20. Imprints from the solar cycle on the helium atom and helium pickup ion distributions

    Directory of Open Access Journals (Sweden)

    D. Rucinski

    2003-06-01

    Full Text Available Neutral interstellar helium atoms penetrate into the solar system almost unaffected by gas–plasma interactions in the heliospheric interface region, and thus can be considered as carriers of original information on the basic parameters (like density, temperature, bulk velocity of the Very Local Interstellar Medium (VLISM. Such information can nowadays be derived from analysis of data obtained from different experimental methods: in situ measurements of He atoms (Ulysses, observations of the solar backscattered He 584 A radiation (EUVE, in situ measurements of He + pickup ions (AMPTE, Ulysses, Wind, SOHO, ACE. In view of the current coordinated international ISSI campaign devoted to the study of the helium focusing cone structure and its evolution, we analyze expected variations of neutral He density, of He + pickup fluxes and of their phase space distributions at various phases of the solar activity cycle based on a realistic time-dependent modelling of the neutral helium and He + pickup ion distributions, which reflect solar cycle-induced variations of the photoionization rate. We show that the neutral helium density values are generally anticorrelated with the solar activity phase and in extreme cases (near the downwind axis the maximum-to-minimum density ratio may even exceed factors of ~ 3 at 1 AU. We also demonstrate that in the upwind hemisphere (at 1 AU and beyond the He + fluxes are correlated with the solar cycle activity, whereas on the downwind side the maximum of the expected flux up to distances of ~ 3 AU occurs around solar minimum epoch, and only further away does the correlation with solar activity become positive. Finally, we present the response of the phase space distribution spectra of He + pickup ions (in the solar wind frame for different epochs of the solar cycle and heliocentric distances from 1 to 5 AU covering the range of Ulysses, Wind and ACE observations.Key words. Solar physics, astrophysics and astronomy

  1. Anderson localization of graphene by helium ion irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Naitou, Y., E-mail: yu-naitou@aist.go.jp [Nanoelectronics Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba 305–8562 (Japan); Ogawa, S. [Nanoelectronics Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 16-1 Onogawa, Tsukuba 305–8569 (Japan)

    2016-04-25

    Irradiation of a single-layer graphene (SLG) with accelerated helium ions (He{sup +}) controllably generates defect distributions, which create a charge carrier scattering source within the SLG. We report direct experimental observation of metal-insulator transition in SLG on SiO{sub 2}/Si substrates induced by Anderson localization. This transition was investigated using scanning capacitance microscopy by monitoring the He{sup +} dose conditions on the SLG. The experimental data show that a defect density of more than ∼1.2% induced Anderson localization. We also investigated the localization length by determining patterned placement of the defects and estimated the length to be several dozen nanometers. These findings provide valuable insight for patterning and designing graphene-based nanostructures using helium ion microscopy.

  2. Effective doping of low energy ions into superfluid helium droplets

    Science.gov (United States)

    Zhang, Jie; Chen, Lei; Freund, William M.; Kong, Wei

    2015-01-01

    We report a facile method of doping cations from an electrospray ionization (ESI) source into superfluid helium droplets. By decelerating and stopping the ion pulse of reserpine and substance P from an ESI source in the path of the droplet beam, about 104 ion-doped droplets (one ion per droplet) can be recorded, corresponding to a pickup efficiency of nearly 1 out of 1000 ions. We attribute the success of this simple approach to the long residence time of the cations in the droplet beam. The resulting size of the doped droplets, on the order of 105/droplet, is measured using deflection and retardation methods. Our method does not require an ion trap in the doping region, which significantly simplifies the experimental setup and procedure for future spectroscopic and diffraction studies. PMID:26298127

  3. Photoionization Energies and Oscillator Strengths of Helium and Helium-like Ions

    Science.gov (United States)

    Faye, N. A. B.; Ndao, A. S.; Konte, A.; Biaye, M.; Wague, A.

    2005-10-01

    We first studied the resonant photoionization of helium-like ions, such as C4+, N5+, and O6+, and determined the wave functions, the excitation energies, and the partial and total widths of the autoionizing states of these ions lying under the n = 3 thresholds of the residual ion. For more detailed analysis of the theory, and a better comprehension of the internal dynamics of atomic resonances and electronic phenomena of correlation, we extended these calculations to other helium-like ions, under higher thresholds (n = 4 and 5) of the hydrogen ions H-, and of Li+, C4+, N5+, and O6+. We were also interested in oscillator strengths. These parameters are important for interpreting the spectra and diagnosing astrophysical and laboratory plasmas, as well as for analyzing the spectra coming from space and determining the composition and relative abundance from the various elements of the stellar and interstellar environment. We sought a better comprehension of the coupling between autoionizing and continuum states and of the phenomena of electronic correlations. We used the method of diagonalization that has been used below the n = 2 threshold of the residual ion. The results are important for astrophysicists and physicists studying matter-radiation interaction and for the invention of new laser systems. We also measured laser-induced chlorophyll fluorescence (LICF) emission spectra of the leaves of some tropical plants using a compact fiber-optic fluorosensor with a continuous-wave violet diode laser as the exciting source and an integrated digital spectrometer to analyze the state of stress of the plants.

  4. submitter Data-driven RBE parameterization for helium ion beams

    CERN Document Server

    Mairani, A; Dokic, I; Valle, S M; Tessonnier, T; Galm, R; Ciocca, M; Parodi, K; Ferrari, A; Jäkel, O; Haberer, T; Pedroni, P; Böhlen, T T

    2016-01-01

    Helium ion beams are expected to be available again in the near future for clinical use. A suitable formalism to obtain relative biological effectiveness (RBE) values for treatment planning (TP) studies is needed. In this work we developed a data-driven RBE parameterization based on published in vitro experimental values. The RBE parameterization has been developed within the framework of the linear-quadratic (LQ) model as a function of the helium linear energy transfer (LET), dose and the tissue specific parameter ${{(\\alpha /\\beta )}_{\\text{ph}}}$ of the LQ model for the reference radiation. Analytic expressions are provided, derived from the collected database, describing the $\\text{RB}{{\\text{E}}_{\\alpha}}={{\\alpha}_{\\text{He}}}/{{\\alpha}_{\\text{ph}}}$ and ${{\\text{R}}_{\\beta}}={{\\beta}_{\\text{He}}}/{{\\beta}_{\\text{ph}}}$ ratios as a function of LET. Calculated RBE values at 2 Gy photon dose and at 10% survival ($\\text{RB}{{\\text{E}}_{10}}$ ) are compared with the experimental ones. Pearson's correlati...

  5. Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions

    Science.gov (United States)

    SRD 124 Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions (Web, free access)   The databases ESTAR, PSTAR, and ASTAR calculate stopping-power and range tables for electrons, protons, or helium ions. Stopping-power and range tables can be calculated for electrons in any user-specified material and for protons and helium ions in 74 materials.

  6. Helium Tagging Infrared Photodissociation Spectroscopy of Reactive Ions.

    Science.gov (United States)

    Roithová, Jana; Gray, Andrew; Andris, Erik; Jašík, Juraj; Gerlich, Dieter

    2016-02-16

    The interrogation of reaction intermediates is key for understanding chemical reactions; however their direct observation and study remains a considerable challenge. Mass spectrometry is one of the most sensitive analytical techniques, and its use to study reaction mixtures is now an established practice. However, the information that can be obtained is limited to elemental analysis and possibly to fragmentation behavior, which is often challenging to analyze. In order to extend the available experimental information, different types of spectroscopy in the infrared and visible region have been combined with mass spectrometry. Spectroscopy of mass selected ions usually utilizes the powerful sensitivity of mass spectrometers, and the absorption of photons is not detected as such but rather translated to mass changes. One approach to accomplish such spectroscopy involves loosely binding a tag to an ion that will be removed by absorption of one photon. We have constructed an ion trapping instrument capable of reaching temperatures that are sufficiently low to enable tagging by helium atoms in situ, thus permitting infrared photodissociation spectroscopy (IRPD) to be carried out. While tagging by larger rare gas atoms, such as neon or argon is also possible, these may cause significant structural changes to small and reactive species, making the use of helium highly beneficial. We discuss the "innocence" of helium as a tag in ion spectroscopy using several case studies. It is shown that helium tagging is effectively innocent when used with benzene dications, not interfering with their structure or IRPD spectrum. We have also provided a case study where we can see that despite its minimal size there are systems where He has a huge effect. A strong influence of the He tagging was shown in the IRPD spectra of HCCl(2+) where large spectral shifts were observed. While the presented systems are rather small, they involve the formation of mixtures of isomers. We have therefore

  7. High Resolution Helium Ion Scanning Microscopy of the Rat Kidney

    Science.gov (United States)

    Rice, William L.; Van Hoek, Alfred N.; Păunescu, Teodor G.; Huynh, Chuong; Goetze, Bernhard; Singh, Bipin; Scipioni, Larry; Stern, Lewis A.; Brown, Dennis

    2013-01-01

    Helium ion scanning microscopy is a novel imaging technology with the potential to provide sub-nanometer resolution images of uncoated biological tissues. So far, however, it has been used mainly in materials science applications. Here, we took advantage of helium ion microscopy to explore the epithelium of the rat kidney with unsurpassed image quality and detail. In addition, we evaluated different tissue preparation methods for their ability to preserve tissue architecture. We found that high contrast, high resolution imaging of the renal tubule surface is possible with a relatively simple processing procedure that consists of transcardial perfusion with aldehyde fixatives, vibratome tissue sectioning, tissue dehydration with graded methanol solutions and careful critical point drying. Coupled with the helium ion system, fine details such as membrane texture and membranous nanoprojections on the glomerular podocytes were visualized, and pores within the filtration slit diaphragm could be seen in much greater detail than in previous scanning EM studies. In the collecting duct, the extensive and striking apical microplicae of the intercalated cells were imaged without the shrunken or distorted appearance that is typical with conventional sample processing and scanning electron microscopy. Membrane depressions visible on principal cells suggest possible endo- or exocytotic events, and central cilia on these cells were imaged with remarkable preservation and clarity. We also demonstrate the use of colloidal gold probes for highlighting specific cell-surface proteins and find that 15 nm gold labels are practical and easily distinguishable, indicating that external labels of various sizes can be used to detect multiple targets in the same tissue. We conclude that this technology represents a technical breakthrough in imaging the topographical ultrastructure of animal tissues. Its use in future studies should allow the study of fine cellular details and provide

  8. High resolution helium ion scanning microscopy of the rat kidney.

    Science.gov (United States)

    Rice, William L; Van Hoek, Alfred N; Păunescu, Teodor G; Huynh, Chuong; Goetze, Bernhard; Singh, Bipin; Scipioni, Larry; Stern, Lewis A; Brown, Dennis

    2013-01-01

    Helium ion scanning microscopy is a novel imaging technology with the potential to provide sub-nanometer resolution images of uncoated biological tissues. So far, however, it has been used mainly in materials science applications. Here, we took advantage of helium ion microscopy to explore the epithelium of the rat kidney with unsurpassed image quality and detail. In addition, we evaluated different tissue preparation methods for their ability to preserve tissue architecture. We found that high contrast, high resolution imaging of the renal tubule surface is possible with a relatively simple processing procedure that consists of transcardial perfusion with aldehyde fixatives, vibratome tissue sectioning, tissue dehydration with graded methanol solutions and careful critical point drying. Coupled with the helium ion system, fine details such as membrane texture and membranous nanoprojections on the glomerular podocytes were visualized, and pores within the filtration slit diaphragm could be seen in much greater detail than in previous scanning EM studies. In the collecting duct, the extensive and striking apical microplicae of the intercalated cells were imaged without the shrunken or distorted appearance that is typical with conventional sample processing and scanning electron microscopy. Membrane depressions visible on principal cells suggest possible endo- or exocytotic events, and central cilia on these cells were imaged with remarkable preservation and clarity. We also demonstrate the use of colloidal gold probes for highlighting specific cell-surface proteins and find that 15 nm gold labels are practical and easily distinguishable, indicating that external labels of various sizes can be used to detect multiple targets in the same tissue. We conclude that this technology represents a technical breakthrough in imaging the topographical ultrastructure of animal tissues. Its use in future studies should allow the study of fine cellular details and provide

  9. High resolution helium ion scanning microscopy of the rat kidney.

    Directory of Open Access Journals (Sweden)

    William L Rice

    Full Text Available Helium ion scanning microscopy is a novel imaging technology with the potential to provide sub-nanometer resolution images of uncoated biological tissues. So far, however, it has been used mainly in materials science applications. Here, we took advantage of helium ion microscopy to explore the epithelium of the rat kidney with unsurpassed image quality and detail. In addition, we evaluated different tissue preparation methods for their ability to preserve tissue architecture. We found that high contrast, high resolution imaging of the renal tubule surface is possible with a relatively simple processing procedure that consists of transcardial perfusion with aldehyde fixatives, vibratome tissue sectioning, tissue dehydration with graded methanol solutions and careful critical point drying. Coupled with the helium ion system, fine details such as membrane texture and membranous nanoprojections on the glomerular podocytes were visualized, and pores within the filtration slit diaphragm could be seen in much greater detail than in previous scanning EM studies. In the collecting duct, the extensive and striking apical microplicae of the intercalated cells were imaged without the shrunken or distorted appearance that is typical with conventional sample processing and scanning electron microscopy. Membrane depressions visible on principal cells suggest possible endo- or exocytotic events, and central cilia on these cells were imaged with remarkable preservation and clarity. We also demonstrate the use of colloidal gold probes for highlighting specific cell-surface proteins and find that 15 nm gold labels are practical and easily distinguishable, indicating that external labels of various sizes can be used to detect multiple targets in the same tissue. We conclude that this technology represents a technical breakthrough in imaging the topographical ultrastructure of animal tissues. Its use in future studies should allow the study of fine cellular details

  10. Imaging of carbon nanomembranes with helium ion microscopy

    Directory of Open Access Journals (Sweden)

    André Beyer

    2015-08-01

    Full Text Available Carbon nanomembranes (CNMs prepared from aromatic self-assembled monolayers constitute a recently developed class of 2D materials. They are made by a combination of self-assembly, radiation-induced cross-linking and the detachment of the cross-linked SAM from its substrate. CNMs can be deposited on arbitrary substrates, including holey and perforated ones, as well as on metallic (transmission electron microscopy grids. Therewith, freestanding membranes with a thickness of 1 nm and macroscopic lateral dimensions can be prepared. Although free-standing CNMs cannot be imaged by light microscopy, charged particle techniques can visualize them. However, CNMs are electrically insulating, which makes them sensitive to charging. We demonstrate that the helium ion microscope (HIM is a good candidate for imaging freestanding CNMs due to its efficient charge compensation tool. Scanning with a beam of helium ions while recording the emitted secondary electrons generates the HIM images. The advantages of HIM are high resolution, high surface sensitivity and large depth of field. The effects of sample charging, imaging of multilayer CNMs as well as imaging artefacts are discussed.

  11. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.; Castro, J.R.; Chen, G.T.Y.; Collier, J.M.; Cartigny, A.; Blakely, E.A.; Lyman, J.T.; Zink, S.R.

    1985-02-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons.

  12. SAXS study of molybdenum irradiated with helium ions

    Science.gov (United States)

    Osamura, Kozo; Suzuki, Hideo

    1983-01-01

    Defects produced by helium ion irradiation have been investigated by means of small-angle X-ray scattering (SAXS) measurements, transmission electron microscope (TEM) and scanning electron microscope (SEM) observations. He + ions with projectile energy of 2 MeV were implanted in thin high-purity molybdenum foils with dose rates of 7-56 μA cm -2 up to total doses of 0.43-3.46 × 10 18 ions cm -2. The critical fluence producing blisters and the blister skin thickness were measured to be about 0.5 × 10 18 ions cm t-2 and 2.8 ± 0.4 μm, respectively, from SEM observations. Two types of bubbles were observed by TEM. The angular dependence of SAXS intensity was explained by the superposition of three Gaussian-shaped scattering curves, suggesting three different types of irradiation defects. Type II, which had a dimension of 4-7 nm, was identified with polygonal bubbles observed by TEM. This type appeared beyond the critical dose of 0.6 × 10 18 ions cm -2. Type III, which had a dimension of 0.6-2.7 nm, was identified with finer bubbles observed by TEM and distinguishable from type II. The SAXS results have been applied to evaluate quantitatively the kinetics of formation of these bubbles.

  13. IR spectroscopy of molecular ions by nonthermal ion ejection from helium nanodroplets

    NARCIS (Netherlands)

    Smolarek, S.; Brauer, N.B.; Buma, W.J.; Drabbels, M.

    2010-01-01

    Infrared spectroscopy provides a means to determine the intrinsic geometrical structures of molecules. Here we present a novel spectroscopic method that uses superfluid helium nanodroplets to record IR spectra of cold molecular ions, in this particular case aniline cations. The method is based on

  14. Imaging and nanofabrication with the helium ion microscope of the Van Leeuwenhoek Laboratory in Delft

    NARCIS (Netherlands)

    Alkemade, P.F.A.; Koster, E.M.; Veldhoven, E. van; Maas, D.J.

    2012-01-01

    Although helium ion microscopy (HIM) was introduced only a few years ago, many new application fields are emerging. The connecting factor between these novel applications is the unique interaction of the primary helium ion beam with the sample material at and just below its surface. In particular,

  15. Visualization of steps and surface reconstructions in Helium Ion Microscopy with atomic precision

    NARCIS (Netherlands)

    Hlawacek, G.; Jankowski, Maciej; Wormeester, Herbert; van Gastel, Raoul; Zandvliet, Henricus J.W.; Poelsema, Bene

    2016-01-01

    Helium Ion Microscopy is known for its surface sensitivity and high lateral resolution. Here, we present results of a Helium Ion Microscopy based investigation of a surface confined alloy of Ag on Pt(111). Based on a change of the work function of 25 meV across the atomically flat terraces we can

  16. Nanostructuring of molybdenum and tungsten surfaces by low-energy helium ions

    NARCIS (Netherlands)

    De Temmerman, G.; Bystrov, K.; Zielinski, J. J.; Balden, M.; Matern, G.; Arnas, C.; Marot, L.

    2012-01-01

    The formation of metallic nanostructures by exposure of molybdenum and tungsten surfaces to high fluxes of low energy helium ions is studied as a function of the ion energy, plasma exposure time, and surface temperature. Helium plasma exposure leads to the formation of nanoscopic filaments on the

  17. Effects of sequential tungsten and helium ion implantation on nano-indentation hardness of tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, D. E. J.; Edmondson, P. D.; Roberts, S. G. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom)

    2013-06-24

    To simulate neutron and helium damage in a fusion reactor first wall sequential self-ion implantation up to 13 dpa followed by helium-ion implantation up to 3000 appm was performed to produce damaged layers of {approx}2 {mu}m depth in pure tungsten. The hardness of these layers was measured using nanoindentation and was studied using transmission electron microscopy. Substantial hardness increases were seen in helium implanted regions, with smaller hardness increases in regions which had already been self-ion implanted, thus, containing pre-existing dislocation loops. This suggests that, for the same helium content, helium trapped in distributed vacancies gives stronger hardening than helium trapped in vacancies condensed into dislocation loops.

  18. Whole-cell imaging at nanometer resolutions using fast and slow focused helium ions.

    Science.gov (United States)

    Chen, Xiao; Udalagama, Chammika N B; Chen, Ce-Belle; Bettiol, Andrew A; Pickard, Daniel S; Venkatesan, T; Watt, Frank

    2011-10-05

    Observations of the interior structure of cells and subcellular organelles are important steps in unraveling organelle functions. Microscopy using helium ions can play a major role in both surface and subcellular imaging because it can provide subnanometer resolutions at the cell surface for slow helium ions, and fast helium ions can penetrate cells without a significant loss of resolution. Slow (e.g., 10-50 keV) helium ion beams can now be focused to subnanometer dimensions (∼0.25 nm), and keV helium ion microscopy can be used to image the surfaces of cells at high resolutions. Because of the ease of neutralizing the sample charge using a flood electron beam, surface charging effects are minimal and therefore cell surfaces can be imaged without the need for a conducting metallic coating. Fast (MeV) helium ions maintain a straight path as they pass through a cell. Along the ion trajectory, the helium ion undergoes multiple electron collisions, and for each collision a small amount of energy is lost to the scattered electron. By measuring the total energy loss of each MeV helium ion as it passes through the cell, we can construct an energy-loss image that is representative of the mass distribution of the cell. This work paves the way to use ions for whole-cell investigations at nanometer resolutions through structural, elemental (via nuclear elastic backscattering), and fluorescence (via ion induced fluorescence) imaging. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  19. Numerical investigation of depth profiling capabilities of helium and neon ions in ion microscopy

    Directory of Open Access Journals (Sweden)

    Patrick Philipp

    2016-11-01

    Full Text Available The analysis of polymers by secondary ion mass spectrometry (SIMS has been a topic of interest for many years. In recent years, the primary ion species evolved from heavy monatomic ions to cluster and massive cluster primary ions in order to preserve a maximum of organic information. The progress in less-damaging sputtering goes along with a loss in lateral resolution for 2D and 3D imaging. By contrast the development of a mass spectrometer as an add-on tool for the helium ion microscope (HIM, which uses finely focussed He+ or Ne+ beams, allows for the analysis of secondary ions and small secondary cluster ions with unprecedented lateral resolution. Irradiation induced damage and depth profiling capabilities obtained with these light rare gas species have been far less investigated than ion species used classically in SIMS. In this paper we simulated the sputtering of multi-layered polymer samples using the BCA (binary collision approximation code SD_TRIM_SP to study preferential sputtering and atomic mixing in such samples up to a fluence of 1018 ions/cm2. Results show that helium primary ions are completely inappropriate for depth profiling applications with this kind of sample materials while results for neon are similar to argon. The latter is commonly used as primary ion species in SIMS. For the two heavier species, layers separated by 10 nm can be distinguished for impact energies of a few keV. These results are encouraging for 3D imaging applications where lateral and depth information are of importance.

  20. Numerical investigation of depth profiling capabilities of helium and neon ions in ion microscopy.

    Science.gov (United States)

    Philipp, Patrick; Rzeznik, Lukasz; Wirtz, Tom

    2016-01-01

    The analysis of polymers by secondary ion mass spectrometry (SIMS) has been a topic of interest for many years. In recent years, the primary ion species evolved from heavy monatomic ions to cluster and massive cluster primary ions in order to preserve a maximum of organic information. The progress in less-damaging sputtering goes along with a loss in lateral resolution for 2D and 3D imaging. By contrast the development of a mass spectrometer as an add-on tool for the helium ion microscope (HIM), which uses finely focussed He+ or Ne+ beams, allows for the analysis of secondary ions and small secondary cluster ions with unprecedented lateral resolution. Irradiation induced damage and depth profiling capabilities obtained with these light rare gas species have been far less investigated than ion species used classically in SIMS. In this paper we simulated the sputtering of multi-layered polymer samples using the BCA (binary collision approximation) code SD_TRIM_SP to study preferential sputtering and atomic mixing in such samples up to a fluence of 1018 ions/cm2. Results show that helium primary ions are completely inappropriate for depth profiling applications with this kind of sample materials while results for neon are similar to argon. The latter is commonly used as primary ion species in SIMS. For the two heavier species, layers separated by 10 nm can be distinguished for impact energies of a few keV. These results are encouraging for 3D imaging applications where lateral and depth information are of importance.

  1. Ion temperature anisotropy in high power helium neutral beam fuelling experiments in JET

    Energy Technology Data Exchange (ETDEWEB)

    Maas, A.C.; Core, W.G.F.; Gerstel, U.C.; Von Hellermann, M.G.; Koenig, R.W.T.; Marcus, F.B. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking

    1994-07-01

    During helium beam fuelling experiments in JET, distinctive anisotropic features have been observed in the velocity distribution function describing both fast and thermal alpha particle populations. During the initial fuelling phase the central helium ion temperature observed perpendicular to the magnetic field is higher than the central electron temperature, while the central helium ion temperature observed parallel to the magnetic field is lower than or equal to the central electron temperature. In order to verify temperature measurements of both perpendicular and parallel lines of sight, other independent methods of deducing the ion temperature are investigated: deuterium ion temperature, deuterium density, comparison with neutron rates and profiles (influence of a possible metastable population of helium). 6 refs., 7 figs.

  2. Hydration of magnesia cubes: a helium ion microscopy study

    Directory of Open Access Journals (Sweden)

    Ruth Schwaiger

    2016-02-01

    Full Text Available Physisorbed water originating from exposure to the ambient can have a strong impact on the structure and chemistry of oxide nanomaterials. The effect can be particularly pronounced when these oxides are in physical contact with a solid substrate such as the ones used for immobilization to perform electron or ion microscopy imaging. We used helium ion microscopy (HIM and investigated morphological changes of vapor-phase-grown MgO cubes after vacuum annealing and pressing into foils of soft and high purity indium. The indium foils were either used as obtained or, for reference, subjected to vacuum drying. After four days of storage in the vacuum chamber of the microscope and at a base pressure of p −7 mbar, we observed on these cubic particles the attack of residual physisorbed water molecules from the indium substrate. As a result, thin magnesium hydroxide layers spontaneously grew, giving rise to characteristic volume expansion effects, which depended on the size of the particles. Rounding of the originally sharp cube edges leads to a significant loss of the morphological definition specific to the MgO cubes. Comparison of different regions within one sample before and after exposure to liquid water reveals different transformation processes, such as the formation of Mg(OH2 shells that act as diffusion barriers for MgO dissolution or the evolution of brucite nanosheets organized in characteristic flower-like microstructures. The findings underline the significant metastability of nanomaterials under both ambient and high-vacuum conditions and show the dramatic effect of ubiquitous water films during storage and characterization of oxide nanomaterials.

  3. Helium ion microscopy for high-resolution visualization of the articular cartilage collagen network.

    Science.gov (United States)

    Vanden Berg-Foels, W S; Scipioni, L; Huynh, C; Wen, X

    2012-05-01

    The articular cartilage collagen network is an important research focus because network disruption results in cartilage degeneration and patient disability. The recently introduced helium ion microscope (HIM), with its smaller probe size, longer depth of field and charge neutralization, has the potential to overcome the inherent limitations of electron microscopy for visualization of collagen network features, particularly at the nanoscale. In this study, we evaluated the capabilities of the helium ion microscope for high-resolution visualization of the articular cartilage collagen network. Images of rabbit knee cartilage were acquired with a helium ion microscope; comparison images were acquired with a field emission scanning electron microscope (FE-SEM) and a transmission electron microscope (TEM). Sharpness of example high-resolution helium ion microscope and field emission scanning electron microscope images was quantified using the 25-75% rise distance metric. The helium ion microscope was able to acquire high-resolution images with unprecedented clarity, with greater sharpness and three-dimensional-like detail of nanoscale fibril morphologies and fibril connections, in samples without conductive coatings. These nanoscale features could not be resolved by field emission scanning electron microscopy, and three-dimensional network structure could not be visualized with transmission electron microscopy. The nanoscale three-dimensional-like visualization capabilities of the helium ion microscope will enable new avenues of investigation in cartilage collagen network research. © 2012 The Authors Journal of Microscopy © 2012 Royal Microscopical Society.

  4. Helium retention in krypton ion pre-irradiated nanochannel W film

    Science.gov (United States)

    Qin, Wenjing; Ren, Feng; Zhang, Jian; Dong, Xiaonan; Feng, Yongjin; Wang, Hui; Tang, Jun; Cai, Guangxu; Wang, Yongqiang; Jiang, Changzhong

    2018-02-01

    Nanochannel tungsten (W) film is a promising candidate as an alternative to bulk W for use in fusion applications. In previous work it has been shown to have good radiation resistance under helium (He) irradiation. To further understand the influence of the irradiation-induced displacement cascade damage on helium retention behaviour in a fusion environment, in this work, nanochannel W film and bulk W were pre-irradiated by 800 keV Kr2+ ions to the fluence of 2.6  ×  1015 ions cm‑2 and subsequently irradiated by 40 keV He+ ions to the fluence of 5  ×  1017 ions cm‑2. The Kr2+ ion pre-irradiation greatly increases helium retention in the form of small clusters and retards the formation of large clusters. It can effectively inhibit surface helium blistering under high temperature annealing. Compared with bulk W, no cracks were found in the nanochannel W film post-irradiated by He+ ions at high fluence. The release of helium from the nanochannel W film is more than one order of magnitude higher than that of bulk W whether they are irradiated by single He+ ions or sequentially irradiated by Kr2+ and He+ ions. Moreover, swelling of the bulk W is more serious than that of the nanochannel film. Therefore, nanochannel W film has a higher radiation tolerance performance in the synergistic irradiation.

  5. A comparison of neon versus helium ion beam induced deposition via Monte Carlo simulations.

    Science.gov (United States)

    Timilsina, Rajendra; Smith, Daryl A; Rack, Philip D

    2013-03-22

    The ion beam induced nanoscale synthesis of PtCx (where x ∼ 5) using the trimethyl (methylcyclopentadienyl)platinum(IV) (MeCpPt(IV)Me3) precursor is investigated by performing Monte Carlo simulations of helium and neon ions. The helium beam leads to more lateral growth relative to the neon beam because of its larger interaction volume. The lateral growth of the nanopillars is dominated by molecules deposited via secondary electrons in both the simulations. Notably, the helium pillars are dominated by SE-I electrons whereas the neon pillars are dominated by SE-II electrons. Using a low precursor residence time of 70 μs, resulting in an equilibrium coverage of ∼4%, the neon simulation has a lower deposition efficiency (3.5%) compared to that of the helium simulation (6.5%). At larger residence time (10 ms) and consequently larger equilibrium coverage (85%) the deposition efficiencies of helium and neon increased to 49% and 21%, respectively; which is dominated by increased lateral growth rates leading to broader pillars. The nanoscale growth is further studied by varying the ion beam diameter at 10 ms precursor residence time. The study shows that total SE yield decreases with increasing beam diameters for both the ion types. However, helium has the larger SE yield as compared to that of neon in both the low and high precursor residence time, and thus pillars are wider in all the simulations studied.

  6. Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection of ^{23}Na^{1+} ions

    Directory of Open Access Journals (Sweden)

    O. Tarvainen

    2016-05-01

    Full Text Available This work describes the utilization of an injected ^{23}Na^{1+} ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 10^{11}  cm^{-3} or higher. The experimental results are compared to simulations of the ^{23}Na^{1+} capture into the helium plasma. The results indicate that the lower breeding efficiency of light ions in comparison to heavier elements is probably due to different capture efficiencies in which the in-flight ionization of the incident 1+ ions plays a vital role.

  7. The Effects of the Pauli Exclusion Principle in Determining the Ionization Energies of the Helium Atom and Helium-Like Ions

    Science.gov (United States)

    Deeney, F. A.; O'Leary, J. P.

    2012-01-01

    For helium and helium-like ions, we have examined the differences between the values of the ionization energies as calculated from the Bohr theory and those measured in experiments. We find that these differences vary linearly with the atomic number of the system. Using this result, we show how the Bohr model for single-electron systems may be…

  8. 15 years experience with helium ion radiotherapy for uvealmelanoma

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Joseph R.; D.H. Char, P.L. Petti; Daftarii, K.; Quivey,J.M.; Singh, R.P.; Blakeley, E.A.; Phillips, T.L.

    1997-06-01

    Purpose: To review the long-term experience of helium iontherapy as a therapeutic alternative to enucleation for uveal melanoma,particularly with respect to survival, local control, and morbidity.Methods and Materials: 347 patients with uveal melanoma were treated withheluim ion RT from 1978-1992. A nonrandomized dose-searching study wasundertaken, with doses progressively reduced from 80 GyE in fivefractionsto 48 GyE in four fractions, given in 3-15 days, mean of 7days. Results: Local control was achieved in 96 percent of patients, withno difference in the rate of local control being seen at 80, 70, 60, or50 GyE in five fractions. At the lowest dose level of 48 GyE in fourfractions, the local control rate fell to 87 percent. Fifteen of 347patients (4 percent) had local regrowth in the eye requiring enucleation(12 patients), laser (1 patient) or reirradiation (2 patients). The timeof appearance of local regrowth ranged from 4 months to 5 yearsposttreatment, with 85 percent occurring within 3 years. Of the 347patients, 208 are alive as of May 1, 1997. The median follow up of allpatients is 8.5 years, range 1-17 years. Kaplan-Maier (K-M) survival is80 percent at 5 years, 76 percent at 10 years, and 72 percent at 15 yearsposttreatment. Patients with tumors not involving the ciliary body have a15-year K-M survival of 80 percent. The results for patients whose tumorsinvolved the ciliary body are poor, with a 15-year K-M survival of 43percent. Seventy-five percent of patients with tumors at least 3.0 mmfrom the fovea and optic nerve, and initial ultrasound height less than6.0 mm, retained vision of 20/200 or better posttreatment. Patients withtumors larger than 6 mm in thickness, or with tumors lying close to theoptic nerve or fovea, have a reduced chance of retaining useful vision.The enucleation rate is 19 percent, 3 percent for local failure and 16percent because of complications of the helium RT, particularlyneovascular glaucoma, which occurred in 35 percent of

  9. Energy and charge distribution of energetic helium ions in the outer radiation belt of the earth

    Science.gov (United States)

    Klecker, B.; Hovestadt, D.; Scholer, M.; Gloeckler, G.; Ipavich, F. M.; Fan, C. Y.

    1983-01-01

    The first direct measurement of the charge states of helium at energies greater than 0.5 MeV/nucleon in the outer radiation belt, obtained aboard the ISEE-1 spacecraft in 1977, is reported. High abundances of singly ionized helium, with He(+)/He(2+) = 0.4 + or - 0.1 at L = 3.3 was found during one perigee pass, with a sudden decrease of that ratio by a factor of about 10 between L = 3.3 and 3.7. It is shown that nonstationary and/or nonadiabatic processes may play an important role for the distribution of helium ions in the outer radiation belt.

  10. Electronic spectroscopy of aniline ions embedded in helium nanodroplets

    NARCIS (Netherlands)

    Brauer, N.B.; Smolarek, S.D.; Zhang, X.; Buma, W.J.; Drabbels, M.

    2011-01-01

    Excitation spectra of the Ã2A2←X̃2B1 and B̃2B1←X̃2B1 transitions of aniline cations embedded in helium nanodroplets are reported. The spectra are characterized by broad asymmetric resonances that consist of an intrinsically broadened zero-phonon line, which partially overlaps with the accompanying

  11. Comparative study of image contrast in scanning electron microscope and helium ion microscope.

    Science.gov (United States)

    O'Connell, R; Chen, Y; Zhang, H; Zhou, Y; Fox, D; Maguire, P; Wang, J J; Rodenburg, C

    2017-12-01

    Images of Ga+ -implanted amorphous silicon layers in a 110 n-type silicon substrate have been collected by a range of detectors in a scanning electron microscope and a helium ion microscope. The effects of the implantation dose and imaging parameters (beam energy, dwell time, etc.) on the image contrast were investigated. We demonstrate a similar relationship for both the helium ion microscope Everhart-Thornley and scanning electron microscope Inlens detectors between the contrast of the images and the Ga+ density and imaging parameters. These results also show that dynamic charging effects have a significant impact on the quantification of the helium ion microscope and scanning electron microscope contrast. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  12. Aluminium surface morphology behaviour under high-flux helium ion bombardment

    Science.gov (United States)

    Girka, O.; Bizyukov, O.; Bogatyrenko, S.; Bizyukov, I.

    2017-08-01

    Samples of aluminium with purity 99.99% wt are irradiated with helium ion beam under ITER-like conditions using FALCON ion source. Aluminium is used as the surrogate material for plasma-material interaction studies. Typical parameters during steady-state exposure are the following: helium ion flux is 2-4 × 1022 m-2 s-1, heat flux is above 1 MW m-2, average ion energy is of 2 keV, and the ion fluence is well above 1027 m-2. Investigation of the surface morphology with SEM shows the formation of the cone-like structures, which develop with fluence increasing. Surface features suddenly disappear at the fluence of 1.06 × 1027 m-2 and then start to grow again. Further fluence increase with step-by-step surface diagnostics shows periodical character of the surface structures growth and degradation.

  13. Helium behaviour in UO{sub 2} through low fluence ion implantation studies

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, P., E-mail: philippe.garcia@cea.fr [CEA – DEN/DEC, Bât. 352, 13108 Saint-Paul-Lez-Durance Cedex (France); Gilabert, E. [Centre d’Et' udes Nucleáires de Bordeaux-Gradignan, Le Haut Vigneau, 33175 Gradignan (France); Martin, G.; Carlot, G.; Sabathier, C. [CEA – DEN/DEC, Bât. 352, 13108 Saint-Paul-Lez-Durance Cedex (France); Sauvage, T.; Desgardin, P.; Barthe, M.-F. [CNRS-CEMHTI, UPR3079, 45071 Orleáns (France)

    2014-05-01

    In this work we focus on experiments involving implantation of 500 keV {sup 3}He ions in sintered polycrystalline material. Samples are implanted at low fluences (∼2 ×10{sup 13} ions/cm{sup 2}) and subsequently isothermally annealed in a highly sensitive thermal desorption spectrometry (TDS) device PIAGARA (Plateforme Interdisciplinaire pour l’Analyse des GAz Rares en Aquitaine). The helium fluencies studied are two to three orders of magnitude lower than previous Nuclear Reaction Analysis (NRA) experiments carried out on identical samples implanted at identical energies. The fractional release of helium obtained in the TDS experiments is interpreted using a three-dimensional axisymmetric diffusion model which enables results to be quantitatively compared to previous NRA data. The analysis shows that helium behaviour is qualitatively independent of ion fluency over three orders of magnitude: helium diffusion appears to be strongly inhibited below 1273 K within the centre of the grains presumably as a result of helium bubble precipitation. The scenario involving diffusion at grain boundaries and in regions adjacent to them observed at higher fluencies is quantitatively confirmed at much lower doses. The main difference lies in the average width of the region in which uninhibited diffusion occurs.

  14. POLAR spacecraft observations of helium ion angular anisotropy in the Earth's radiation belts

    Directory of Open Access Journals (Sweden)

    W. N. Spjeldvik

    1999-06-01

    Full Text Available New observations of energetic helium ion fluxes in the Earth's radiation belts have been obtained with the CAMMICE/HIT instrument on the ISTP/GGS POLAR spacecraft during the extended geomagnetically low activity period April through October 1996. POLAR executes a high inclination trajectory that crosses over both polar cap regions and passes over the geomagnetic equator in the heart of the radiation belts. The latter attribute makes possible direct observations of nearly the full equatorial helium ion pitch angle distributions in the heart of the Earth's radiation belt region. Additionally, the spacecraft often re-encounters the same geomagnetic flux tube at a substantially off-equatorial location within a few tens of minutes prior to or after the equatorial crossing. This makes both the equatorial pitch angle distribution and an expanded view of the local off-equatorial pitch angle distribution observable. The orbit of POLAR also permitted observations to be made in conjugate magnetic local time sectors over the course of the same day, and this afforded direct comparison of observations on diametrically opposite locations in the Earth's radiation belt region at closely spaced times. Results from four helium ion data channels covering ion kinetic energies from 520 to 8200 KeV show that the distributions display trapped particle characteristics with angular flux peaks for equatorially mirroring particles as one might reasonably expect. However, the helium ion pitch angle distributions generally flattened out for equatorial pitch angles below about 45°. Significant and systematic helium ion anisotropy difference at conjugate magnetic local time were also observed, and we report quiet time azimuthal variations of the anisotropy index.Key words. Magnetospheric physics (energetic particles · trapped; magnetospheric configuration and dynamics; plasmasphere

  15. Comparison of basic features of proton and helium ion pencil beams in water using GATE.

    Science.gov (United States)

    Ströbele, Julia; Schreiner, Thomas; Fuchs, Hermann; Georg, Dietmar

    2012-09-01

    The aim of this study was to investigate the basic features of helium ions for their possible application in advanced radiotherapy and to benchmark them against protons, the current particle of choice in the low linear energy transfer (LET) range. Geant4 Application for Emission Tomography (GATE) simulations were performed with beams of 1x10(7) monodirectional particles traversing a water phantom. Initial energies ranged from 50 to 250 MeV per nucleon (MeV/A). The following parameters were evaluated: particle range at the distal 80% of maximum energy deposition (E(max)), width of the Bragg peak (BP) at 60% of E(max), and dose fall-off width between 80% and 20% of E(max) for longitudinal spectra. In addition the fragmentation tail was quantified in terms of length, percental energy deposition, and contributing particles. For each energy lateral profiles were registered along the beam axis and the FWHM at four different depths was extracted. Besides the comparison of parameters between the two particle types, results were also compared to data in the literature. As expected, the position of the BP as a function of initial kinetic energy showed similar values for protons and helium ions, with deviations smaller than 1.3%. The quantitative results of the Monte Carlo (MC) study showed less range straggling effects and smaller lateral deflections for helium ions compared to protons for the investigated energy range. On average, an about 56% reduction of the width of the BP and a 48% reduction of the dose fall-off was observed for helium ions compared to protons. Both the width of the BP and the dose fall-off width as a function of particle range or energy showed an almost linear increase with increasing energy. The tail length increased from 55.9 mm to 592.7 mm and the deposited energy increased from 0.5% to 7.3% for energies between 90 and 250 MeV/A. Lateral profiles of helium ions were about 52% narrower than those of protons. Due to their mass and charge helium

  16. Low flux and low energy helium ion implantation into tungsten using a dedicated plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Pentecoste, Lucile [GREMI, CNRS/Université d’Orléans, 14 rue d’Issoudun, B.P. 6744, 45067 Orléans Cedex2 (France); Thomann, Anne-Lise, E-mail: anne-lise.thomann@univ-orleans.fr [GREMI, CNRS/Université d’Orléans, 14 rue d’Issoudun, B.P. 6744, 45067 Orléans Cedex2 (France); Melhem, Amer; Caillard, Amael; Cuynet, Stéphane; Lecas, Thomas; Brault, Pascal [GREMI, CNRS/Université d’Orléans, 14 rue d’Issoudun, B.P. 6744, 45067 Orléans Cedex2 (France); Desgardin, Pierre; Barthe, Marie-France [CNRS, UPR3079 CEMHTI, 1D avenue de la Recherche Scientifique, 45071 Orléans Cedex2 (France)

    2016-09-15

    The aim of this work is to investigate the first stages of defect formation in tungsten (W) due to the accumulation of helium (He) atoms inside the crystal lattice. To reach the required implantation conditions, i.e. low He ion fluxes (10{sup 11}–10{sup 14} ions.cm{sup 2}.s{sup −1}) and kinetic energies below the W atom displacement threshold (about 500 eV for He{sup +}), an ICP source has been designed and connected to a diffusion chamber. Implantation conditions have been characterized by means of complementary diagnostics modified for measurements in this very low density helium plasma. It was shown that lowest ion fluxes could only be reached for the discharge working in capacitive mode either in α or γ regime. Special attention was paid to control the energy gained by the ions by acceleration through the sheath at the direct current biased substrate. At very low helium pressure, in α regime, a broad ion energy distribution function was evidenced, whereas a peak centered on the potential difference between the plasma and the biased substrate was found at higher pressures in the γ mode. Polycrystalline tungsten samples were exposed to the helium plasma in both regimes of the discharge and characterized by positron annihilation spectroscopy in order to detect the formed vacancy defects. It was found that W vacancies are able to be formed just by helium accumulation and that the same final implanted state is reached, whatever the operating mode of the capacitive discharge.

  17. Towards Polarization Measurements of Laser-accelerated Helium-3 Ions

    OpenAIRE

    Engin, Ilhan

    2016-01-01

    In the framework of this thesis, preparatory investigations for the spin-polarization measurement of 3He ions from laser-induced plasmas have been performed.Therefore, experiments aiming at an efficient laser-induced ion acceleration out of a 4He gas target were carried out at two high-intensity laser facilities: the Arcturus laser at Heinrich-Heine-Universität Düsseldorf as well as PHELIX at GSI Darmstadt. The scientific goal of both experiments was to investigate the ion-acceleration proces...

  18. Study of fluid mechanical helium argon ion laser

    Science.gov (United States)

    1972-01-01

    An approach to an argon ion laser based on gasdynamic techniques is presented. Improvement in efficiency and power output are achieved by eliminating high heat rejection problems and plasma confinement of the seal-off conventional lasers. The process of producing population inversion between the same energy levels, as in the conventional argon ion laser, has been divided into two phases by separating each other from the processes of ionization and subsequent excitation. Line drawings and graphs are included to amplify the theoretical presentation.

  19. Towards polarization measurements of laser-accelerated helium-3 ions

    Energy Technology Data Exchange (ETDEWEB)

    Engin, Ilhan

    2015-08-28

    In the framework of this thesis, preparatory investigations for the spin-polarization measurement of {sup 3}He ions from laser-induced plasmas have been performed. Therefore, experiments aiming at an efficient laser-induced ion acceleration out of a {sup 4}He gas target were carried out at two high-intensity laser facilities: the Arcturus laser at Heinrich-Heine-Universitaet Duesseldorf as well as PHELIX at GSI Darmstadt. The scientific goal of both experiments was to investigate the ion-acceleration process in underdense plasmas by measuring the ion energy spectra and the angular distribution of the ion signal around the gas-jet target. Laser-accelerated MeV-He-ions could successfully be detected. The main acceleration direction at large angles with regard to the laser propagation direction was determined. In a second step, unpolarized {sup 3}He gas was attached in order to cross-check the experimental results with those of {sup 4}He. With the help of the achieved ion yield data, the expected rates of the fusion reaction D({sup 3}He,p){sup 4}He in the polarized case have been estimated: the information regarding the fusion proton yield from this nuclear reaction allows an experimentally based estimation for future experiments with pre-polarized {sup 3}He gas as plasma target. The experimental data is in line with supporting Particle-in-Cell (PIC) simulations performed on the Juelich supercomputers. For this purpose, the simulated target was defined as a neutral gas. The use of pre-polarized {sup 3}He gas demands a special preparation of a polarized {sup 3}He target for laser-acceleration experiments. This layout includes an (external) homogeneous magnetic holding field (field strength of ∝1.4 mT) for storing the pre-polarized gas for long time durations inside the PHELIX target chamber. For this purpose, a precise Halbach array consisting of horizontally arranged rings with built-in permanent magnets had to be designed, optimized, and constructed to deliver high

  20. Theory of the n = 2 levels in muonic helium-3 ions

    Science.gov (United States)

    Franke, Beatrice; Krauth, Julian J.; Antognini, Aldo; Diepold, Marc; Kottmann, Franz; Pohl, Randolf

    2017-12-01

    The present knowledge of Lamb shift, fine-, and hyperfine structure of the 2S and 2P states in muonic helium-3 ions is reviewed in anticipation of the results of a first measurement of several 2S → 2P transition frequencies in the muonic helium-3 ion, μ3He+. This ion is the bound state of a single negative muon μ- and a bare helium-3 nucleus (helion), 3He++. A term-by-term comparison of all available sources, including new, updated, and so far unpublished calculations, reveals reliable values and uncertainties of the QED and nuclear structure-dependent contributions to the Lamb shift and the hyperfine splitting. These values are essential for the determination of the helion rms charge radius and the nuclear structure effects to the hyperfine splitting in μ3He+. With this review we continue our series of theory summaries in light muonic atoms [see A. Antognini et al., Ann. Phys. 331, 127 (2013); J.J. Krauth et al., Ann. Phys. 366, 168 (2016); and M. Diepold et al. https://arxiv.org/abs/1606.05231">arXiv:1606.05231 (2016)].

  1. Applicability of the Atkins model to the ion behavior in superfluid helium

    Science.gov (United States)

    Leiderer, P.; Shikin, V.

    2009-02-01

    The properties of ion clusters in superfluid helium are usually treated within the model proposed by Atkins (the snowball model). However, although a solid sphere of radius Ra around the seed ion can actually exist, it is vitally important to which extent it really governs the scattering mechanisms of various thermal excitations at the cluster. Detailed analysis of available data on the phonon as well as the impurity and Stokes mobilities reveals that the true unifying factor in the discussed picture is a power-law density enhancement in the vicinity of the seed charged particle caused by the polarization forces rather than the radius Ra

  2. Effect of gold ion irradiation on helium migration in fluoroapatites investigated with nuclear reaction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Miro, S. [CRISMAT, ENSICAEN, 6 Bd du Marechal Juin, F-14050 Caen cedex (France); Studer, F. [CRISMAT, ENSICAEN, 6 Bd du Marechal Juin, F-14050 Caen cedex (France)]. E-mail: francis.studer@ensicaen.fr; Costantini, J.-M. [CEA Saclay, DMN/SRMA, F-91191 Gif-sur-Yvette cedex (France); Berger, P. [CEA Saclay, Laboratoire Pierre-Suee (CEA/CNRS), F-91191 Gif-sur-Yvette cedex (France); Haussy, J. [CEA DIF, DCRE/SEIM, BP 12, F-91680 Bruyeres-le-Chatel cedex (France); Trouslard, P. [CEA Saclay, LEMFI/INSTN/DRECAM, F-91191 Gif-sur-Yvette cedex (France); Grob, J.-J. [CNRS-InESS, 23, rue du Loess, B.P. 20, F-67037 Strasbourg cedex (France)

    2007-05-31

    In the context of nuclear waste storage, the knowledge of the effect of irradiation on the diffusion of helium produced by {alpha}-decays in apatites is an important issue. The analysis of implanted {sup 3}He diffusion for two compositions was carried out with the {sup 3}He(d,p){sup 4}He nuclear reaction by using a deuteron milli- or micro-beam. Upon 163-MeV Au-ion irradiation, a significant fraction of {sup 3}He atoms migrated towards the surface below which they were trapped, whereas a proportion of {sup 3}He atoms remained trapped in the end-of-range region. Moreover, a clear helium loss was determined. These radiation-induced migration effects are enhanced in Ca{sub 10}(PO{sub 4}){sub 6}F{sub 2} compared with the Ca{sub 4}Nd{sub 6}(SiO{sub 4}){sub 6}F{sub 2}.

  3. Light Ion Yields from Bombardment of Thick Targets by Protons, Helium-4 and Iron-56

    Science.gov (United States)

    Castellanos, Luis A.; McGirl, Natalie A.; Srikrishna, Ashwin P.; Heilbronn, Lawrence H.; Tessa, Chiara La; Rusek, Adam; Sivertz, Michael; Blattnig, Steve; Clowdsley, Martha; Slaba, Tony; Zeitlin, Cary

    2017-09-01

    In March 2016 accelerator-based experiments colliding protons (0.4 and 0.8 GeV), helium (0.4 AGeV) and iron (0.4 and 0.8 AGeV) on thick aluminum targets with surface densities of 20, 40, and 60 g/cm2 were performed at the National Aeronautics and Space Administration Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory. Two targets were utilized in each experimental configuration. Hydrogen and helium ions were detected using organic liquid scintillators in conjunction with thin plastic scintillators at 10°, 30°, 45°, 60°, 80°, and 135° from beam axis. Time-of-flight techniques and pulse shape discrimination were used to identify light ion species in order to generate double differential energy spectra of the light ion fragments. Comparisons of these measured yields were compared with Monte Carlo calculations generated by MCNP6. These yields will be used to quantify uncertainty in radiation transport codes utilized in risk assessment for spaceflight missions with prolonged exposures to galactic cosmic rays.

  4. Robust valley polarization of helium ion modified atomically thin MoS2

    Science.gov (United States)

    Klein, J.; Kuc, A.; Nolinder, A.; Altzschner, M.; Wierzbowski, J.; Sigger, F.; Kreupl, F.; Finley, J. J.; Wurstbauer, U.; Holleitner, A. W.; Kaniber, M.

    2018-01-01

    Atomically thin semiconductors have dimensions that are commensurate with critical feature sizes of future optoelectronic devices defined using electron/ion beam lithography. Robustness of their emergent optical and valleytronic properties is essential for typical exposure doses used during fabrication. Here, we explore how focused helium ion bombardement affects the intrinsic vibrational, luminescence and valleytronic properties of atomically thin MoS2 . By probing the disorder dependent vibrational response we deduce the interdefect distance by applying a phonon confinement model. We show that the increasing interdefect distance correlates with disorder-related luminscence arising 180 meV below the neutral exciton emission. We perform ab initio density functional theory of a variety of defect related morphologies, which yield first indications on the origin of the observed additional luminescence. Remarkably, no significant reduction of free exciton valley polarization is observed until the interdefect distance approaches a few nanometers, namely the size of the free exciton Bohr radius. Our findings pave the way for direct writing of sub-10 nm nanoscale valleytronic devices and circuits using focused helium ions.

  5. Radioprotection by DMSO in nitrogen-saturated mammalian cells exposed to helium ion beams

    Science.gov (United States)

    Hirayama, Ryoichi; Matsumoto, Yoshitaka; Kase, Yuki; Noguchi, Miho; Ando, Koichi; Ito, Atsushi; Okayasu, Ryuichi; Furusawa, Yoshiya

    2009-12-01

    The contribution of OH radical-mediated indirect action by particle beams under hypoxic irradiation condition was investigated by using a radical scavenger. V79 cells were irradiated with 150 MeV/nucleon helium ions at an LET of 2.2 keV/μm in the presence or absence of DMSO, and their colony survivals were determined. The contribution of indirect action to cell killing under hypoxic condition was estimated to be 52±9%. We conclude that OH radical-mediated indirect action still has a half in total contribution on cell killing under hypoxic condition.

  6. Investigation of mixed ion fields in the forward direction for 220.5 MeV/u helium ion beams: comparison between water and PMMA targets

    Science.gov (United States)

    Aricò, G.; Gehrke, T.; Jakubek, J.; Gallas, R.; Berke, S.; Jäkel, O.; Mairani, A.; Ferrari, A.; Martišíková, M.

    2017-10-01

    Currently there is a rising interest in helium ion beams for radiotherapy. For benchmarking of the physical beam models used in treatment planning, there is a need for experimental data on the composition and spatial distribution of mixed ion fields. Of particular interest are the attenuation of the primary helium ion fluence and the build-up of secondary hydrogen ions due to nuclear interactions. The aim of this work was to provide such data with an enhanced precision. Moreover, the validity and limits of the mixed ion field equivalence between water and PMMA targets were investigated. Experiments with a 220.5 MeV/u helium ion pencil beam were performed at the Heidelberg Ion-Beam Therapy Center in Germany. The compact detection system used for ion tracking and identification was solely based on Timepix position-sensitive semiconductor detectors. In comparison to standard techniques, this system is two orders of magnitude smaller, and provides higher precision and flexibility. The numbers of outgoing helium and hydrogen ions per primary helium ion as well as the lateral particle distributions were quantitatively investigated in the forward direction behind water and PMMA targets with 5.2-18 cm water equivalent thickness (WET). Comparing water and PMMA targets with the same WET, we found that significant differences in the amount of outgoing helium and hydrogen ions and in the lateral particle distributions arise for target thicknesses above 10 cm WET. The experimental results concerning hydrogen ions emerging from the targets were reproduced reasonably well by Monte Carlo simulations using the FLUKA code. Concerning the amount of outgoing helium ions, significant differences of 3-15% were found between experiments and simulations. We conclude that if PMMA is used in place of water in dosimetry, differences in the dose distributions could arise close to the edges of the field, in particular for deep seated targets. The results presented in this publication are

  7. Spectroscopic study of energetic helium-ion irradiation effects on nuclear graphite tiles

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Wan; Lee, K.W. [Department of Physics, Korea University, Seoul 136-713 (Korea, Republic of); Choi, D.M.; Noh, S.J.; Kim, H.S. [Department of Applied Physics, Dankook University, Yongin 448-701 (Korea, Republic of); Lee, Cheol Eui, E-mail: rscel@korea.ac.kr [Department of Physics, Korea University, Seoul 136-713 (Korea, Republic of)

    2016-02-01

    Highlights: • Energetic helium-ion irradiation on nuclear graphite tiles studied for plasma facing components. • XPS reveals recrystallization at low dose irradiation and DLC sites at higher doses. • Raman spectroscopy reveals increasing diamond-like defects and structural deformation. • Average inter-defect distance obtained as a function of irradiation dose from Raman intensities. - Abstract: Helium ion-irradiation effects on the nuclear graphite tiles were studied in order to understand the structural modifications and damages that can be produced by fusion reaction in tokamaks. The surface morphological changes due to increasing dose of the irradiation were examined by the field-effect scanning electron microscopy, and X-ray photoelectron spectroscopy elucidated the changes in the shallow surface bonding configurations caused by the energetic irradiation. Raman spectroscopy revealed the structural defects and diamond-like carbon sites that increased with increasing irradiation dose, and the average inter-defect distance was found from the Raman peak intensities as a function of the irradiation dose.

  8. Water equivalent thickness values of materials used in beams of protons, helium, carbon and iron ions

    Science.gov (United States)

    Zhang, Rui; Taddei, Phillip J; Fitzek, Markus M; Newhauser, Wayne D

    2010-01-01

    Heavy charged particle beam radiotherapy for cancer is of increasing interest because it delivers a highly conformal radiation dose to the target volume. Accurate knowledge of the range of a heavy charged particle beam after it penetrates a patient’s body or other materials in the beam line is very important and is usually stated in terms of the water equivalent thickness (WET). However, methods of calculating WET for heavy charged particle beams are lacking. Our objective was to test several simple analytical formulas previously developed for proton beams for their ability to calculate WET values for materials exposed to beams of protons, helium, carbon and iron ions. Experimentally measured heavy charged particle beam ranges and WET values from an iterative numerical method were compared with the WET values calculated by the analytical formulas. Inmost cases, the deviations were within 1 mm. We conclude that the analytical formulas originally developed for proton beams can also be used to calculate WET values for helium, carbon and iron ion beams with good accuracy. PMID:20371908

  9. Low-energy collisions of helium clusters with size-selected cobalt cluster ions

    Science.gov (United States)

    Odaka, Hideho; Ichihashi, Masahiko

    2017-04-01

    Collisions of helium clusters with size-selected cobalt cluster ions, Com+ (m ≤ 5), were studied experimentally by using a merging beam technique. The product ions, Com+Hen (cluster complexes), were mass-analyzed, and this result indicates that more than 20 helium atoms can be attached onto Com+ at the relative velocities of 103 m/s. The measured size distributions of the cluster complexes indicate that there are relatively stable complexes: Co2+Hen (n = 2, 4, 6, and 12), Co3+Hen (n = 3, 6), Co4+He4, and Co5+Hen (n = 3, 6, 8, and 10). These stabilities are explained in terms of their geometric structures. The yields of the cluster complexes were also measured as a function of the relative velocity (1 × 102-4 × 103 m/s), and this result demonstrates that the main interaction in the collision process changes with the increase of the collision energy from the electrostatic interaction, which includes the induced deformation of HeN, to the hard-sphere interaction. Supplementary material in the form of one pdf file available from the Journal web page at http://https://doi.org/10.1140/epjd/e2017-80015-0

  10. Nanoscale helium ion microscopic analysis of collagen fibrillar changes following femtosecond laser dissection of human cornea.

    Science.gov (United States)

    Riau, Andri K; Poh, Rebekah; Pickard, Daniel S; Park, Chris H J; Chaurasia, Shyam S; Mehta, Jodhbir S

    2014-08-01

    Over the last decade, femtosecond lasers have emerged as an important tool to perform accurate and fine dissections with minimal collateral damage in biological tissue. The most common surgical procedure in medicine utilizing femtosecond laser is LASIK. During the femtosecond laser dissection process, the corneal collagen fibers inevitably undergo biomechanical and thermal changes on a sub-micro- or even a nanoscale level, which can potentially lead to post-surgical complications. In this study, we utilized helium ion microscopy, complemented with transmission electron microscopy to examine the femtosecond laser-induced collagen fibrillar damage in ex vivo human corneas. We found that the biomechanical damage induced by laser etching, generation of tissue bridges, and expansion of cavitation bubble and its subsequent collapse, created distortion to the surrounding collagen lamellae. Femtosecond laser-induced thermal damage was characterized by collapsed collagen lamellae, loss of collagen banding, collagen coiling, and presence of spherical debris. Our findings have shown the ability of helium ion microscopy to provide high resolution images with unprecedented detail of nanoscale fibrillar morphological changes in order to assess a tissue damage, which could not be resolved by conventional scanning electron microscopy previously. This imaging technology has also given us a better understanding of the tissue-laser interactions in a nano-structural manner and their possible effects on post-operative wound recovery.

  11. Ultrastructural analysis of wild type and mutant Drosophila melanogaster using helium ion microscopy.

    Science.gov (United States)

    Boseman, Adam; Nowlin, Kyle; Ashraf, Sarmadia; Yang, Jijin; Lajeunesse, Dennis

    2013-08-01

    Insects have evolved numerous adaptations to survive a variety of environmental conditions. Given that the primary interface between insects and the environment is mediated through their skin or cuticle, many of these adaptations are found in extraordinary cuticle diversity both in morphology and structure. Not all of these adaptions manifest themselves in changes in the chemical composition of the cuticle but rather as elaborations of the surface structures of the cuticle. Typically the examination of these micro- and nanoscale structures has been performed using scanning electron microscopy (SEM). Typically, in order to decrease surface charging and increase resolution, an obscuring conductive layer is applied to the sample surface, but this layer limits the ability to identify nanoscale surface structures. In this paper we use a new technology, helium ion microscopy (HIM) to examine surface structures on the cuticle of wild type and mutant Drosophila. Helium ion microscopy permits high resolution imaging of biological samples without the need for coating. We compare HIM to traditional SEM and demonstrate certain advantages of this type of microscopy, with our focus being high resolution characterization of nanostructures on the cuticle of Drosophila melanogaster and potentially other biological specimens. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Water equivalent thickness values of materials used in beams of protons, helium, carbon and iron ions.

    Science.gov (United States)

    Zhang, Rui; Taddei, Phillip J; Fitzek, Markus M; Newhauser, Wayne D

    2010-05-07

    Heavy charged particle beam radiotherapy for cancer is of increasing interest because it delivers a highly conformal radiation dose to the target volume. Accurate knowledge of the range of a heavy charged particle beam after it penetrates a patient's body or other materials in the beam line is very important and is usually stated in terms of the water equivalent thickness (WET). However, methods of calculating WET for heavy charged particle beams are lacking. Our objective was to test several simple analytical formulas previously developed for proton beams for their ability to calculate WET values for materials exposed to beams of protons, helium, carbon and iron ions. Experimentally measured heavy charged particle beam ranges and WET values from an iterative numerical method were compared with the WET values calculated by the analytical formulas. In most cases, the deviations were within 1 mm. We conclude that the analytical formulas originally developed for proton beams can also be used to calculate WET values for helium, carbon and iron ion beams with good accuracy.

  13. Mechanical properties of tungsten following rhenium ion and helium plasma exposure

    Directory of Open Access Journals (Sweden)

    C.S. Corr

    2017-08-01

    Full Text Available Mechanical properties of Tungsten (W samples irradiated with 2 MeV Rhenium (Re ions and helium (He plasma were investigated using nanoindentation. It was found that there was an increase in hardness for all samples following separate irradiation with both Re ion and He plasma. A slight increase in hardness was obtained for combined exposures. A comparable increase in hardness was observed for a pure He plasma with a sample temperature of 473 K and 1273 K. Optical interferometry was employed to compare surface modification of the samples. Grazing incidence small angle x-ray scattering confirmed He nano-bubble formation of approximately 1 nm diameter in the higher temperature sample, which was not observed with samples at the lower temperatures.

  14. Gas porosity evolution and ion-implanted helium behavior in reactor ferritic/martensitic and austenitic steels

    Science.gov (United States)

    Chernov, I. I.; Kalin, B. A.; Staltsov, M. S.; Oo, Kyi Zin; Binyukova, S. Yu.; Staltsova, O. S.; Polyansky, A. A.; Ageev, V. S.; Nikitina, A. A.

    2015-04-01

    The peculiarities of gas porosity formation and helium retention and release in reactor ferritic/martensitic EP-450 and EP-450-ODS and austenitic ChS-68 steels are investigated by transmission electron microscopy and helium thermal desorption spectrometry (HTDS). The samples were irradiated by 40 keV He+ ions up to a fluence of 5 · 1020 m-2 at 293 and 923 K. An nonuniform distribution of helium bubbles and high-level gas swelling in ferritic/martensitic steels were found at high-temperature helium implantation. The same irradiation conditions result in formation of uniformly distributed helium bubbles and low-level swelling in ChS-68 steel. Temperature range of helium release from EP-450-ODS steel was considerably wider in comparison to HTDS-spectra of the EP-450 steel. A considerable quantity of helium is released from ODS steel in the high-temperature range after the main peak of the HTDS-spectrum.

  15. Early Comparison of the Transport of Helium Ions into Different RAFM Steels and Sillicon Carbide for TBM

    Energy Technology Data Exchange (ETDEWEB)

    Castro, P.

    2015-07-01

    In this paper the early comparison of the transport of Helium Ions into different reduced activation ferritic-martensitic steels, and silicon carbide is presented, both with He Ions of 0,66 KeV, 150KeV and 1 MeV to improve the understanding of radiation damage in different alloys of Test Blanket Modules. The radiation damage in nuclear alloys is well known, however the damage in new materials to be used in ITER and DEMO has to be researched. This is the case of RAFM Steels as ODS and also SiC can be a key component of several Test Blanket Modules. Differences in the transport of helium ions over ODS can be relevant for the use of a European test blanket module as the Helium Cooled Lithium Lead-HCLL with the best early assessment of damage with the TRIM program. Similarly the differences in the transport of helium ions over SiC can be relevant for the use of a test blanket module as the Dual Coolant Lithium LeadDCLL. (Author)

  16. Extraction of radioactive positive ions across the surface of superfluid helium : A new method to produce cold radioactive nuclear beams

    NARCIS (Netherlands)

    Huang, WX; Dendooven, P; Gloos, K; Takahashi, N; Pekola, JP; Aysto, J

    Alpha-decay recoils Rn-219 were stopped in superfluid helium and positive ions were extracted by electric field into the vapour phase. This first quantitative observation of extraction was successfully conducted using highly sensitive radioactivity detection. The efficiency for extraction across the

  17. Ultrafast nonlinear control of progressively loaded, single plasmonic nanoantennas fabricated using helium ion milling.

    Science.gov (United States)

    Wang, Yudong; Abb, Martina; Boden, Stuart A; Aizpurua, Javier; de Groot, C H; Muskens, Otto L

    2013-01-01

    We demonstrate milling of partial antenna gaps and narrow conducting bridges with nanometer precision using a helium ion beam microscope. Single particle spectroscopy shows large shifts in the plasmonic mode spectrum of the milled antennas, associated with the transition from capacitive to conductive gap loading. A conducting bridge of nanometer height is found sufficient to shift the antenna from the capacitive to the conductive coupling regime, in agreement with circuit theory. Picosecond pump-probe spectroscopy reveals an enhanced nonlinear response for partially milled antennas, reaching an optimum value for an intermediate bridge height. Our results show that manipulation of the antenna load can be used to increase the nonlinear response of plasmonic antennas.

  18. Abundances, charge states, and energy spectra of helium and heavy ions during solar particle events

    Science.gov (United States)

    Gloeckler, G.; Sciambi, R.; Fan, C. Y.; Hovestadt, D.

    1975-01-01

    Carbon and oxygen energy spectra observed during several solar events indicate a systematic deviation of these spectra from a simple power law: the spectra bend down below about 100 keV/nuc and the amount of this bending is highly correlated with the size of the flare, as measured by the 'event averaged' flux of 130-220 keV protons. The energy spectra of helium computed for the same time periods do not show a similar feature. A large variability of the alpha/CNO ratio is found from event to event (from 2 to about 20 at 40 keV/nuc), and in all cases examined the carbon and oxygen nuclei are nearly fully stripped. These results are interpreted as evidence for storage of energetic ions in hot coronal regions, followed by strong adiabatic deceleration.

  19. Helium Ion Microscopy (HIM) for the imaging of biological samples at sub-nanometer resolution

    Science.gov (United States)

    Joens, Matthew S.; Huynh, Chuong; Kasuboski, James M.; Ferranti, David; Sigal, Yury J.; Zeitvogel, Fabian; Obst, Martin; Burkhardt, Claus J.; Curran, Kevin P.; Chalasani, Sreekanth H.; Stern, Lewis A.; Goetze, Bernhard; Fitzpatrick, James A. J.

    2013-01-01

    Scanning Electron Microscopy (SEM) has long been the standard in imaging the sub-micrometer surface ultrastructure of both hard and soft materials. In the case of biological samples, it has provided great insights into their physical architecture. However, three of the fundamental challenges in the SEM imaging of soft materials are that of limited imaging resolution at high magnification, charging caused by the insulating properties of most biological samples and the loss of subtle surface features by heavy metal coating. These challenges have recently been overcome with the development of the Helium Ion Microscope (HIM), which boasts advances in charge reduction, minimized sample damage, high surface contrast without the need for metal coating, increased depth of field, and 5 angstrom imaging resolution. We demonstrate the advantages of HIM for imaging biological surfaces as well as compare and contrast the effects of sample preparation techniques and their consequences on sub-nanometer ultrastructure. PMID:24343236

  20. An effective method for trapping ion beams in superfluid helium for laser spectroscopy experiments

    Directory of Open Access Journals (Sweden)

    Yang X.F

    2014-03-01

    Full Text Available A novel laser spectroscopy technique -“OROCHI” (Optical Radioisotopes Observation in Condensed Helium as Ion-catcher has been proposed. This method aimed to investigate the structure of exotic nuclei systematically by measuring nuclear spins and moments. For in-situ laser spectroscopy of atoms in He II, a method to trap atoms precisely at the observation region of laser is highly needed. In this work, a setup composed of a degrader, two plastic scintillators and a photon detection system is further tested and verified for adjusting and checking the stopping position of 84–87Rb beam. Details of the current setup, experimental results using this method are presented.

  1. Particularities of LaB sub 6 behaviour under bombardment with helium and argon energetic ions

    CERN Document Server

    Lesnyakov, G G; Klyimenko, V M; Pershyin, V F

    2002-01-01

    The investigation results on the bombardment of LaB sub 6 of 18 - 26% porosity with 20 keV helium and 0.5 keV argon ions are presented. the main contribution to the erosion is made by the material removal from the surface, which confirms the earlier conclusions about weakness of boundary grain, pores, and formation of cracks and round dislocation etch pits. It is shown that, during the bombardment as a dose is increased, a layer is formed on the LaB sub 6 surface with a subsequent change of the relative content of two elements. It is determined when and where one can expect the formation of LaB sub 4 under bombardment of the surface.

  2. Implementation of spot scanning dose optimization and dose calculation for helium ions in Hyperion

    DEFF Research Database (Denmark)

    Fuchs, Hermann; Alber, Markus; Schreiner, Thomas

    2015-01-01

    and integrated into the treatment planning system Hyperion. METHODS: Current knowledge on RBE of (4)He together with linear energy transfer considerations motivated an empirical depth-dependent "zonal" RBE model. In the plateau region, a RBE of 1.0 was assumed, followed by an increasing RBE up to 2......) for four treatment sites, i.e., a prostate, a base-of-skull, a pediatric, and a head-and-neck tumor case. Separate treatment plans taking into account physical dose calculation only or using biological modeling were created for protons and (4)He. RESULTS: Comparison of Monte Carlo and Hyperion calculated...... published so far. The advantage of (4)He seems to lie in the reduction of dose to surrounding tissue and to OARs. Nevertheless, additional biological experiments and treatment planning studies with larger patient numbers and more tumor indications are necessary to study the possible benefits of helium ion...

  3. Helium ions at the heidelberg ion beam therapy center: comparisons between FLUKA Monte Carlo code predictions and dosimetric measurements

    Science.gov (United States)

    Tessonnier, T.; Mairani, A.; Brons, S.; Sala, P.; Cerutti, F.; Ferrari, A.; Haberer, T.; Debus, J.; Parodi, K.

    2017-08-01

    In the field of particle therapy helium ion beams could offer an alternative for radiotherapy treatments, owing to their interesting physical and biological properties intermediate between protons and carbon ions. We present in this work the comparisons and validations of the Monte Carlo FLUKA code against in-depth dosimetric measurements acquired at the Heidelberg Ion Beam Therapy Center (HIT). Depth dose distributions in water with and without ripple filter, lateral profiles at different depths in water and a spread-out Bragg peak were investigated. After experimentally-driven tuning of the less known initial beam characteristics in vacuum (beam lateral size and momentum spread) and simulation parameters (water ionization potential), comparisons of depth dose distributions were performed between simulations and measurements, which showed overall good agreement with range differences below 0.1 mm and dose-weighted average dose-differences below 2.3% throughout the entire energy range. Comparisons of lateral dose profiles showed differences in full-width-half-maximum lower than 0.7 mm. Measurements of the spread-out Bragg peak indicated differences with simulations below 1% in the high dose regions and 3% in all other regions, with a range difference less than 0.5 mm. Despite the promising results, some discrepancies between simulations and measurements were observed, particularly at high energies. These differences were attributed to an underestimation of dose contributions from secondary particles at large angles, as seen in a triple Gaussian parametrization of the lateral profiles along the depth. However, the results allowed us to validate FLUKA simulations against measurements, confirming its suitability for 4He ion beam modeling in preparation of clinical establishment at HIT. Future activities building on this work will include treatment plan comparisons using validated biological models between proton and helium ions, either within a Monte Carlo

  4. Nanometer scale elemental analysis in the helium ion microscope using time of flight spectrometry.

    Science.gov (United States)

    Klingner, N; Heller, R; Hlawacek, G; Borany, J von; Notte, J; Huang, J; Facsko, S

    2016-03-01

    Time of flight backscattering spectrometry (ToF-BS) was successfully implemented in a helium ion microscope (HIM). Its integration introduces the ability to perform laterally resolved elemental analysis as well as elemental depth profiling on the nm scale. A lateral resolution of ≤54nm and a time resolution of Δt≤17ns(Δt/t≤5.4%) are achieved. By using the energy of the backscattered particles for contrast generation, we introduce a new imaging method to the HIM allowing direct elemental mapping as well as local spectrometry. In addition laterally resolved time of flight secondary ion mass spectrometry (ToF-SIMS) can be performed with the same setup. Time of flight is implemented by pulsing the primary ion beam. This is achieved in a cost effective and minimal invasive way that does not influence the high resolution capabilities of the microscope when operating in standard secondary electron (SE) imaging mode. This technique can thus be easily adapted to existing devices. The particular implementation of ToF-BS and ToF-SIMS techniques are described, results are presented and advantages, difficulties and limitations of this new techniques are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. submitter Biologically optimized helium ion plans: calculation approach and its in vitro validation

    CERN Document Server

    Mairani, A; Magro, G; Tessonnier, T; Kamp, F; Carlson, D J; Ciocca, M; Cerutti, F; Sala, P R; Ferrari, A; Böhlen, T T; Jäkel, O; Parodi, K; Debus, J; Abdollahi, A; Haberer, T

    2016-01-01

    Treatment planning studies on the biological effect of raster-scanned helium ion beams should be performed, together with their experimental verification, before their clinical application at the Heidelberg Ion Beam Therapy Center (HIT). For this purpose, we introduce a novel calculation approach based on integrating data-driven biological models in our Monte Carlo treatment planning (MCTP) tool. Dealing with a mixed radiation field, the biological effect of the primary $^4$He ion beams, of the secondary $^3$He and $^4$He (Z  =  2) fragments and of the produced protons, deuterons and tritons (Z  =  1) has to be taken into account. A spread-out Bragg peak (SOBP) in water, representative of a clinically-relevant scenario, has been biologically optimized with the MCTP and then delivered at HIT. Predictions of cell survival and RBE for a tumor cell line, characterized by ${{(\\alpha /\\beta )}_{\\text{ph}}}=5.4$ Gy, have been successfully compared against measured clonogenic survival data. The mean ...

  6. Biologically optimized helium ion plans: calculation approach and its in vitro validation

    Science.gov (United States)

    Mairani, A.; Dokic, I.; Magro, G.; Tessonnier, T.; Kamp, F.; Carlson, D. J.; Ciocca, M.; Cerutti, F.; Sala, P. R.; Ferrari, A.; Böhlen, T. T.; Jäkel, O.; Parodi, K.; Debus, J.; Abdollahi, A.; Haberer, T.

    2016-06-01

    Treatment planning studies on the biological effect of raster-scanned helium ion beams should be performed, together with their experimental verification, before their clinical application at the Heidelberg Ion Beam Therapy Center (HIT). For this purpose, we introduce a novel calculation approach based on integrating data-driven biological models in our Monte Carlo treatment planning (MCTP) tool. Dealing with a mixed radiation field, the biological effect of the primary 4He ion beams, of the secondary 3He and 4He (Z  =  2) fragments and of the produced protons, deuterons and tritons (Z  =  1) has to be taken into account. A spread-out Bragg peak (SOBP) in water, representative of a clinically-relevant scenario, has been biologically optimized with the MCTP and then delivered at HIT. Predictions of cell survival and RBE for a tumor cell line, characterized by {{(α /β )}\\text{ph}}=5.4 Gy, have been successfully compared against measured clonogenic survival data. The mean absolute survival variation ({μΔ \\text{S}} ) between model predictions and experimental data was 5.3%  ±  0.9%. A sensitivity study, i.e. quantifying the variation of the estimations for the studied plan as a function of the applied phenomenological modelling approach, has been performed. The feasibility of a simpler biological modelling based on dose-averaged LET (linear energy transfer) has been tested. Moreover, comparisons with biophysical models such as the local effect model (LEM) and the repair-misrepair-fixation (RMF) model were performed. {μΔ \\text{S}} values for the LEM and the RMF model were, respectively, 4.5%  ±  0.8% and 5.8%  ±  1.1%. The satisfactorily agreement found in this work for the studied SOBP, representative of clinically-relevant scenario, suggests that the introduced approach could be applied for an accurate estimation of the biological effect for helium ion radiotherapy.

  7. Complementary study of the internal porous silicon layers formed under high-dose implantation of helium ions

    Energy Technology Data Exchange (ETDEWEB)

    Lomov, A. A., E-mail: lomov@ftian.ru; Myakon’kikh, A. V. [Russian Academy of Sciences, Institute of Physics and Technology (Russian Federation); Chesnokov, Yu. M. [National Research Centre “Kurchatov Institute” (Russian Federation); Shemukhin, A. A.; Oreshko, A. P. [Moscow State University (Russian Federation)

    2017-03-15

    The surface layers of Si(001) substrates subjected to plasma-immersion implantation of helium ions with an energy of 2–5 keV and a dose of 5 × 10{sup 17} cm{sup –2} have been investigated using high-resolution X-ray reflectivity, Rutherford backscattering, and transmission electron microscopy. The electron density depth profile in the surface layer formed by helium ions is obtained, and its elemental and phase compositions are determined. This layer is found to have a complex structure and consist of an upper amorphous sublayer and a layer with a porosity of 30–35% beneath. It is shown that the porous layer has the sharpest boundaries at a lower energy of implantable ions.

  8. Interpreting the data on helium-ion scattering in metallic films

    Science.gov (United States)

    Bednyakov, A. A.

    2017-07-01

    Earlier measurements of angular distributions in the multiple scattering of a helium-ion beam with energy below 300 keV on Al yielded rather unexpected results: the ratio between the half-width of the measured angular distribution, (θ1/2)e, and that predicted with the Moliere-Bethe theory, (θ1/2)MB, proved to stay almost constant throughout the investigated energy range. At the same time, one could expect the (θ1/2)e/(θ1/2)MB value to be affected by the beam-content variation due to the charge-exchange scattering. Towards resolving this problem, we compute the interaction potentials between the He++, He+, and He0 ions and the scattering atoms and reveal the electron-screening effects on the scattering process. Thereby, we explain the energy dependence of (θ1/2)e/(θ1/2)MB observed in the old and new measurements carried out at higher beam energies.

  9. Helium ions for radiotherapy? Physical and biological verifications of a novel treatment modality

    Energy Technology Data Exchange (ETDEWEB)

    Krämer, Michael, E-mail: m.kraemer@gsi.de; Scifoni, Emanuele; Schuy, Christoph; Rovituso, Marta; Maier, Andreas; Kaderka, Robert; Kraft-Weyrather, Wilma [Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstr. 1, 64291 Darmstadt (Germany); Tinganelli, Walter; Durante, Marco [Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstr. 1, 64291 Darmstadt, Germany and Trento Institute for Fundamental Physics and Application (TIFPA-INFN), 38123, via Sommarive 14, Trento (Italy); Brons, Stephan; Tessonnier, Thomas [Heidelberger Ionenstrahl-Therapiezentrum (HIT), Im Neuenheimer Feld 450, 69120 Heidelberg, Germany and Radioonkologie und Strahlentherapie, Universitätsklinikums Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg (Germany); Parodi, Katia [Heidelberger Ionenstrahl-Therapiezentrum (HIT), Im Neuenheimer Feld 450, 69120 Heidelberg (Germany); Radioonkologie und Strahlentherapie, Universitätsklinikums Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg (Germany); Ludwig-Maximilians-Universitaet Muenchen (LMU Munich), Department of Medical Physics, Am Coulombwall 1, 85748 Munich (Germany)

    2016-04-15

    Purpose: Modern facilities for actively scanned ion beam radiotherapy allow in principle the use of helium beams, which could present specific advantages, especially for pediatric tumors. In order to assess the potential use of these beams for radiotherapy, i.e., to create realistic treatment plans, the authors set up a dedicated {sup 4}He beam model, providing base data for their treatment planning system TRiP98, and they have reported that in this work together with its physical and biological validations. Methods: A semiempirical beam model for the physical depth dose deposition and the production of nuclear fragments was developed and introduced in TRiP98. For the biological effect calculations the last version of the local effect model was used. The model predictions were experimentally verified at the HIT facility. The primary beam attenuation and the characteristics of secondary charged particles at various depth in water were investigated using {sup 4}He ion beams of 200 MeV/u. The nuclear charge of secondary fragments was identified using a ΔE/E telescope. 3D absorbed dose distributions were measured with pin point ionization chambers and the biological dosimetry experiments were realized irradiating a Chinese hamster ovary cells stack arranged in an extended target. Results: The few experimental data available on basic physical processes are reproduced by their beam model. The experimental verification of absorbed dose distributions in extended target volumes yields an overall agreement, with a slight underestimation of the lateral spread. Cell survival along a 4 cm extended target is reproduced with remarkable accuracy. Conclusions: The authors presented a simple simulation model for therapeutical {sup 4}He beams which they introduced in TRiP98, and which is validated experimentally by means of physical and biological dosimetries. Thus, it is now possible to perform detailed treatment planning studies with {sup 4}He beams, either exclusively or in

  10. Implementation of spot scanning dose optimization and dose calculation for helium ions in Hyperion.

    Science.gov (United States)

    Fuchs, Hermann; Alber, Markus; Schreiner, Thomas; Georg, Dietmar

    2015-09-01

    Helium ions ((4)He) may supplement current particle beam therapy strategies as they possess advantages in physical dose distribution over protons. To assess potential clinical advantages, a dose calculation module accounting for relative biological effectiveness (RBE) was developed and integrated into the treatment planning system Hyperion. Current knowledge on RBE of (4)He together with linear energy transfer considerations motivated an empirical depth-dependent "zonal" RBE model. In the plateau region, a RBE of 1.0 was assumed, followed by an increasing RBE up to 2.8 at the Bragg-peak region, which was then kept constant over the fragmentation tail. To account for a variable proton RBE, the same model concept was also applied to protons with a maximum RBE of 1.6. Both RBE models were added to a previously developed pencil beam algorithm for physical dose calculation and included into the treatment planning system Hyperion. The implementation was validated against Monte Carlo simulations within a water phantom using γ-index evaluation. The potential benefits of (4)He based treatment plans were explored in a preliminary treatment planning comparison (against protons) for four treatment sites, i.e., a prostate, a base-of-skull, a pediatric, and a head-and-neck tumor case. Separate treatment plans taking into account physical dose calculation only or using biological modeling were created for protons and (4)He. Comparison of Monte Carlo and Hyperion calculated doses resulted in a γ mean of 0.3, with 3.4% of the values above 1 and γ 1% of 1.5 and better. Treatment plan evaluation showed comparable planning target volume coverage for both particles, with slightly increased coverage for (4)He. Organ at risk (OAR) doses were generally reduced using (4)He, some by more than to 30%. Improvements of (4)He over protons were more pronounced for treatment plans taking biological effects into account. All OAR doses were within tolerances specified in the QUANTEC report. The

  11. Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg Ion Beam Therapy Center

    Science.gov (United States)

    Tessonnier, T.; Böhlen, T. T.; Ceruti, F.; Ferrari, A.; Sala, P.; Brons, S.; Haberer, T.; Debus, J.; Parodi, K.; Mairani, A.

    2017-08-01

    The introduction of ‘new’ ion species in particle therapy needs to be supported by a thorough assessment of their dosimetric properties and by treatment planning comparisons with clinically used proton and carbon ion beams. In addition to the latter two ions, helium and oxygen ion beams are foreseen at the Heidelberg Ion Beam Therapy Center (HIT) as potential assets for improving clinical outcomes in the near future. We present in this study a dosimetric validation of a FLUKA-based Monte Carlo treatment planning tool (MCTP) for protons, helium, carbon and oxygen ions for spread-out Bragg peaks in water. The comparisons between the ions show the dosimetric advantages of helium and heavier ion beams in terms of their distal and lateral fall-offs with respect to protons, reducing the lateral size of the region receiving 50% of the planned dose up to 12 mm. However, carbon and oxygen ions showed significant doses beyond the target due to the higher fragmentation tail compared to lighter ions (p and He), up to 25%. The Monte Carlo predictions were found to be in excellent geometrical agreement with the measurements, with deviations below 1 mm for all parameters investigated such as target and lateral size as well as distal fall-offs. Measured and simulated absolute dose values agreed within about 2.5% on the overall dose distributions. The MCTP tool, which supports the usage of multiple state-of-the-art relative biological effectiveness models, will provide a solid engine for treatment planning comparisons at HIT.

  12. The effect of low energy helium ion irradiation on tungsten-tantalum (W-Ta) alloys under fusion relevant conditions

    Science.gov (United States)

    Gonderman, S.; Tripathi, J. K.; Novakowski, T. J.; Sizyuk, T.; Hassanein, A.

    2017-08-01

    Currently, tungsten remains the best candidate for plasma-facing components (PFCs) for future fusion devices because of its high melting point, low erosion, and strong mechanical properties. However, continued investigation has shown tungsten to undergo severe morphology changes under fusion-like conditions. These results motivate the study of innovative PFC materials which are resistant to surface morphology evolution. The goal of this work is to examine tungsten-tantalum (W-Ta) alloys, a potential PFC material, and their response to low energy helium ion irradiation. Specifically, W-Ta samples are exposed to 100 eV helium irradiations with a flux of 1.15 × 1021 ions m-2 s-1, at 873 K, 1023 K, and 1173 K for 1 h duration. Scanning electron microscopy (SEM) reveals significant changes in surface deterioration due to helium ion irradiation as a function of both temperature and tantalum concentration in W-Ta samples. X-Ray Diffraction (XRD) studies show a slight lattice parameter expansion in W-Ta alloy samples compared to pure W samples. The observed lattice parameter expansion in W-Ta alloy samples (proportional to increasing Ta wt.% concentrations) reflect significant differences observed in the evolution of surface morphology, i.e., fuzz development processes for both increasing Ta wt.% concentration and target temperature. These results suggest a correlation between the observed morphology differences and the induced crystal structure change caused by the presence of tantalum. Shifts in the XRD peaks before and after 100 eV helium irradiation with a flux of 1.15 × 1021 ions m-2 s-1, 1023 K, for 1 h showed a significant difference in the magnitude of the shift. This has suggested a possible link between the atomic spacing of the material and the accumulated damage. Ongoing research is needed on W-Ta alloys and other innovative materials for their application as irradiation resistant materials in future fusion or irradiation environments.

  13. Enhanced End-Contacts by Helium Ion Bombardment to Improve Graphene-Metal Contacts

    Directory of Open Access Journals (Sweden)

    Kunpeng Jia

    2016-08-01

    Full Text Available Low contact resistance between graphene and metals is of paramount importance to fabricate high performance graphene-based devices. In this paper, the impact of both defects induced by helium ion (He+ bombardment and annealing on the contact resistance between graphene and various metals (Ag, Pd, and Pt were systematically explored. It is found that the contact resistances between all metals and graphene are remarkably reduced after annealing, indicating that not only chemically adsorbed metal (Pd but also physically adsorbed metals (Ag and Pt readily form end-contacts at intrinsic defect locations in graphene. In order to further improve the contact properties between Ag, Pd, and Pt metals and graphene, a novel method in which self-aligned He+ bombardment to induce exotic defects in graphene and subsequent thermal annealing to form end-contacts was proposed. By using this method, the contact resistance is reduced significantly by 15.1% and 40.1% for Ag/graphene and Pd/graphene contacts with He+ bombardment compared to their counterparts without He+ bombardment. For the Pt/graphene contact, the contact resistance is, however, not reduced as anticipated with He+ bombardment and this might be ascribed to either inappropriate He+ bombardment dose, or inapplicable method of He+ bombardment in reducing contact resistance for Pt/graphene contact. The joint efforts of as-formed end-contacts and excess created defects in graphene are discussed as the cause responsible for the reduction of contact resistance.

  14. High-resolution helium ion microscopy of epididymal epithelial cells and their interaction with spermatozoa.

    Science.gov (United States)

    Păunescu, Teodor G; Shum, Winnie W C; Huynh, Chuong; Lechner, Lorenz; Goetze, Bernhard; Brown, Dennis; Breton, Sylvie

    2014-10-01

    We examined the rat and mouse epididymis using helium ion microscopy (HIM), a novel imaging technology that uses a scanning beam of He(+) ions to produce nanometer resolution images of uncoated biological samples. Various tissue fixation, sectioning and dehydration methods were evaluated for their ability to preserve tissue architecture. The cauda epididymidis was luminally perfused in vivo to remove most spermatozoa and the apical surface of the epithelial lining was exposed. Fixed epididymis samples were then subjected to critical point drying (CPD) and HIM. Apical stereocilia in principal cells and smaller apical membrane extensions in clear cells were clearly distinguishable in both rat and mouse epididymis using this technology. After perfusion with an activating solution containing CPT-cAMP, a permeant analog of cAMP, clear cells exhibited an increase in the number and size of membrane ruffles or microplicae. In contrast, principal cells did not exhibit detectable structural modifications. High-resolution HIM imaging clearly showed the ultrastructure of residual sperm cells, including the presence of concentric rings on the midpiece, and of cytoplasmic droplets in some spermatozoa. Close epithelium-sperm interactions were also detected. We found a number of sperm cells whose heads were anchored within the epididymal epithelium. In certain cases, the surface of the sperm cytoplasmic droplet was covered with vesicle-like structures whose size is consistent with that of epididymosomes. In conclusion, we describe here the first application of HIM technology to the study of the structure and morphology of the rodent epididymis. HIM technology represents a major imaging breakthrough that can be successfully applied to study the epididymis and spermatozoa, with the goal of advancing our understanding of their structure and function. © The Author 2014. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All

  15. Impact of helium ion energy modulation on tungsten surface morphology and nano-tendril growth

    Science.gov (United States)

    Woller, K. B.; Whyte, D. G.; Wright, G. M.

    2017-06-01

    Time-modulated helium (He) ion energy (e.g. V Bias  =  -50  +  25·sin(2πf RF · t), f RF  =  13.56 MHz) is demonstrated to strongly affect the development of tungsten (W) surface morphology that results from He plasma irradiation in the DIONISOS linear plasma experiment. Nano-tendril bundles (NTBs), which appear as isolated ‘islands’ of nano-tendrils, can rapidly grow on an otherwise smooth W surface. This is in contrast to previously seen full-surface coverage of nano-tendril growth known as ‘fuzz’. When tall NTBs form, less than 15% of the surface contains nano-tendrils. The NTB surface coverage changes with growth conditions and the total volume of nano-tendrils in the NTBs is observed to be up to a factor of 16 larger than when fuzz is grown. This indicates that long-range W surface transport underlies nano-tendril formation. Surface temperature 870-1220 K, the DC bias potential  -30 to  -70 V, and the ion flux density 4.4  ×  1021-1.1  ×  1022 He · m-2 · s-1 are varied in the experiments. NTBs form at similar conditions as fuzz with the critical difference being the RF modulation of the ion energy bombarding the W, another indication of the importance of W surface transport. Mass loss measurements indicate net erosion with a yield of 1-8  ×  10-4 W/He when NTBs form; erosion that is not attributable to chemical or physical sputtering by He or impurities in the plasma. The erosion is correlated to the NTB growth, based on post-exposure inspection by electron microscopy indicating that NTBs are prone to loss from the surface. NTB growth is compared to the empirical growth-erosion model of fuzz, showing NTBs grow up to a factor of 100 times taller than the expected fuzz layer depth under DC bias conditions. Insights into nano-tendril growth provided by this new growth regime are discussed. Strategies to mitigate W fuzz growth may inadvertently result in rapid localized nano-tendril bundle

  16. Helium ion microscopy of enamel crystallites and extracellular tooth enamel matrix

    Science.gov (United States)

    Bidlack, Felicitas B.; Huynh, Chuong; Marshman, Jeffrey; Goetze, Bernhard

    2014-01-01

    An unresolved problem in tooth enamel studies has been to analyze simultaneously and with sufficient spatial resolution both mineral and organic phases in their three dimensional (3D) organization in a given specimen. This study aims to address this need using high-resolution imaging to analyze the 3D structural organization of the enamel matrix, especially amelogenin, in relation to forming enamel crystals. Chemically fixed hemi-mandibles from wild type mice were embedded in LR White acrylic resin, polished and briefly etched to expose the organic matrix in developing tooth enamel. Full-length amelogenin was labeled with specific antibodies and 10 nm immuno-gold. This allowed us to use and compare two different high-resolution imaging techniques for the analysis of uncoated samples. Helium ion microscopy (HIM) was applied to study the spatial organization of organic and mineral structures, while field emission scanning electron microscopy (FE-SEM) in various modes, including backscattered electron detection, allowed us to discern the gold-labeled proteins. Wild type enamel in late secretory to early maturation stage reveals adjacent to ameloblasts a lengthwise parallel alignment of the enamel matrix proteins, including full-length amelogenin proteins, which then transitions into a more heterogeneous appearance with increasing distance from the mineralization front. The matrix adjacent to crystal bundles forms a smooth and lacey sheath, whereas between enamel prisms it is organized into spherical components that are interspersed with rod-shaped protein. These findings highlight first, that the heterogeneous organization of the enamel matrix can be visualized in mineralized en bloc samples. Second, our results illustrate that the combination of these techniques is a powerful approach to elucidate the 3D structural organization of organic matrix molecules in mineralizing tissue in nanometer resolution. PMID:25346697

  17. Helium ion microscopy of enamel crystallites and extracellular tooth enamel matrix.

    Science.gov (United States)

    Bidlack, Felicitas B; Huynh, Chuong; Marshman, Jeffrey; Goetze, Bernhard

    2014-01-01

    An unresolved problem in tooth enamel studies has been to analyze simultaneously and with sufficient spatial resolution both mineral and organic phases in their three dimensional (3D) organization in a given specimen. This study aims to address this need using high-resolution imaging to analyze the 3D structural organization of the enamel matrix, especially amelogenin, in relation to forming enamel crystals. Chemically fixed hemi-mandibles from wild type mice were embedded in LR White acrylic resin, polished and briefly etched to expose the organic matrix in developing tooth enamel. Full-length amelogenin was labeled with specific antibodies and 10 nm immuno-gold. This allowed us to use and compare two different high-resolution imaging techniques for the analysis of uncoated samples. Helium ion microscopy (HIM) was applied to study the spatial organization of organic and mineral structures, while field emission scanning electron microscopy (FE-SEM) in various modes, including backscattered electron detection, allowed us to discern the gold-labeled proteins. Wild type enamel in late secretory to early maturation stage reveals adjacent to ameloblasts a lengthwise parallel alignment of the enamel matrix proteins, including full-length amelogenin proteins, which then transitions into a more heterogeneous appearance with increasing distance from the mineralization front. The matrix adjacent to crystal bundles forms a smooth and lacey sheath, whereas between enamel prisms it is organized into spherical components that are interspersed with rod-shaped protein. These findings highlight first, that the heterogeneous organization of the enamel matrix can be visualized in mineralized en bloc samples. Second, our results illustrate that the combination of these techniques is a powerful approach to elucidate the 3D structural organization of organic matrix molecules in mineralizing tissue in nanometer resolution.

  18. Radiative properties of molecular nitrogen ions produced by helium Penning ionization and argon effects

    Science.gov (United States)

    Miller, George, III; Song, Kyo-Dong

    1994-01-01

    The development of hypersonic aerospace vehicles requires a better understanding on the thermal and chemical nonequilibrium kinetics of participating species in shock layers. The computational fluid dynamic (CFD) codes developed for such flowfields overestimate the radiation in the spectral region of 300 - 600 nm. A speculation for this overestimation is that inclusion of Ar, CO2, and H2O at the upper atmosphere flight region makes a significant impact on radiative kinetics of molecular nitrogen ions. To define the effects of minority species on the radiative kinetics of N2(+), an experimental setup was made by using the helium Penning ionization. The vibrational and rotational temperature were measured by mapping the vibrational and rotational distributions of N2(+) emission with high spectroscopic resolution and absolute intensity measurements. Measured vibrational temperatures were in the range from 18,000 to 36,000 K, and rotational temperatures were in the range from 300 to 370 K. The irradiance of 391.44 nm line and rotational and vibrational temperatures were analyzed to define argon and CO2 effects on the N2(+) emission. When Ar or CO2 is injected with N2, the rotational temperature did not change. The irradiances were reduced by 34 percent and 78 percent for the 50 percent of mixture of Ar and CO2, respectively. The vibrational temperatures were increased by 24.1 percent and 82.9 percent for the 50 percent of mixture of Ar and CO2, respectively. It appears that there are no significant effects from small concentrations of Ar and CO2 at the upper atmosphere flight region.

  19. Dynamics of the reaction of the N/sup +/ ion with hydrogen isotopes and helium

    Energy Technology Data Exchange (ETDEWEB)

    Ruska, W.E.W.

    1976-06-28

    Molecular beam techniques were used to study the reactive and non-reactive scattering of the nitrogen positive ion from hydrogen isotopes and helium, at energies above the stability limit for spectator stripping. Reactive scattering was observed from H/sub 2/ and HD targets. Non-reactive scattering was observed from H/sub 2/ and D/sub 2/ targets, and from He at one energy. A correlation diagram for the system is presented and compared with the available a priori calculations. Two surfaces are expected to lead to reaction. One is a /sup 3/A/sub 2/ - /sup 3/PI surface, the other, a /sup 3/B/sub 1/ - /sup 3/..sigma../sup -/ surface. Collinear approaches are expected to be most reactive on the /sup 3/B/sub 1/ - /sup 3/..sigma../sup -/ surface; noncollinear, on the /sup 3/A/sub 1/ - /sup 3/PI surface. Theoretical models are presented in which an incident hard sphere A, representing the projectile ion, strikes one of a pair of hard spheres B-C representing the B hydrogen molecule. After an impulsive A-B collision, an impulsive B-C collision may take place. The relative energy of A to B is then examined, and a reactive event is considered to have occurred if the energy is less than the dissociation energy for the A-B molecule. This model is treated both in the collinear case and in three dimensions. A graphical technique for the collinear case is summarized and applied to reaction on the /sup 3/B/sub 1/ - /sup 3/..sigma../sup -/ surface. An integral equation for the three-dimensional case is developed. A synthesis of two treatments, representing the behavior of the system on both reactive surfaces, and considering the charge-exchange channel, correctly predicts the observed product distribution. Predictions are also presented for the as yet unobserved case of reactive scattering from a D/sub 2/ target.

  20. Development and testing of a pulsed helium ion source for probing materials and warm dense matter studies

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Q., E-mail: qji@lbl.gov; Seidl, P. A.; Waldron, W. L.; Takakuwa, J. H.; Persaud, A.; Schenkel, T. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Friedman, A.; Grote, D. P.; Barnard, J. J. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2016-02-15

    The neutralized drift compression experiment was designed and commissioned as a pulsed, linear induction accelerator to drive thin targets to warm dense matter (WDM) states with peak temperatures of ∼1 eV using intense, short pulses (∼1 ns) of 1.2 MeV lithium ions. At that kinetic energy, heating a thin target foil near the Bragg peak energy using He{sup +} ions leads to more uniform energy deposition of the target material than Li{sup +} ions. Experiments show that a higher current density of helium ions can be delivered from a plasma source compared to Li{sup +} ions from a hot plate type ion source. He{sup +} beam pulses as high as 200 mA at the peak and 4 μs long were measured from a multi-aperture 7-cm-diameter emission area. Within ±5% variation, the uniform beam area is approximately 6 cm across. The accelerated and compressed pulsed ion beams can be used for materials studies and isochoric heating of target materials for high energy density physics experiments and WDM studies.

  1. Stopping power accuracy and achievable spatial resolution of helium ion imaging using a prototype particle CT detector system

    Directory of Open Access Journals (Sweden)

    Volz Lennart

    2017-09-01

    Full Text Available A precise relative stopping power map of the patient is crucial for accurate particle therapy. Charged particle imaging determines the stopping power either tomographically – particle computed tomography (pCT – or by combining prior knowledge from particle radiography (pRad and x-ray CT. Generally, multiple Coulomb scattering limits the spatial resolution. Compared to protons, heavier particles scatter less due to their lower charge/mass ratio. A theoretical framework to predict the most likely trajectory of particles in matter was developed for light ions up to carbon and was found to be the most accurate for helium comparing for fixed initial velocity. To further investigate the potential of helium in particle imaging, helium computed tomography (HeCT and radiography (HeRad were studied at the Heidel-berg Ion-Beam Therapy Centre (HIT using a prototype pCT detector system registering individual particles, originally developed by the U.S. pCT collaboration. Several phantoms were investigated: modules of the Catphan QA phantom for analysis of spatial resolution and achievable stopping power accuracy, a paediatric head phantom (CIRS and a custom-made phantom comprised of animal meat enclosed in a 2 % agarose mixture representing human tissue. The pCT images were reconstructed applying the CARP iterative reconstruction algorithm. The MTF10% was investigated using a sharp edge gradient technique. HeRad provides a spatial resolution above that of protons (MTF1010%=6.07 lp/cm for HeRad versus MTF10%=3.35 lp/cm for proton radiography. For HeCT, the spatial resolution was limited by the number of projections acquired (90 projections for a full scan. The RSP accuracy for all inserts of the Catphan CTP404 module was found to be 2.5% or better and is subject to further optimisation. In conclusion, helium imaging appears to offer higher spatial resolution compared to proton imaging. In future studies, the advantage of helium imaging compared to other

  2. Zur Anwendung der Naturraumerkundung im Tienschan, Kirgisistan

    OpenAIRE

    Gottschling, Hagen

    2008-01-01

    Die Naturraumerkundung nach KOPP, JÄGER & SUCCOW (1982) ist ein umfassendes landschaftsökologisches Methodenkonzept, auf welchem die forstliche Standortserkundung in Ostdeutschland basiert (siehe KOPP & SCHWANECKE 1994, SCHULZE & KOPP 1995) und auch bereits bei der Moorforschung breite Anwendung gefunden hat (siehe SUCCOW 1988, SUCCOW & JOOSTEN 2001). Mit der Naturraumerkundung lassen sich die Zusammenhänge zwischen Standort, Vegetation und Nutzung sehr gut erfassen, und bezüglich ökologische...

  3. Energy Reflected from Solid Targets Bombarded keV Protons and Helium Ions

    DEFF Research Database (Denmark)

    Andersen, Hans Henrik; Lenskjaer, T.; Sidenius, G.

    1976-01-01

    The energy‐reflection coefficient γ has been measured for keV protons impinging on Cu, Au, and Pb and helium impinging on Si, Ag, Ta, and Pb. The results are obtained by entirely independent techniques in three different laboratories. They agree within the stated accuracies of 10%. For a given...

  4. Observation of reduction of secondary electron emission from helium ion impact due to plasma-generated nanostructured tungsten fuzz

    Science.gov (United States)

    Hollmann, E. M.; Doerner, R. P.; Nishijima, D.; Pigarov, A. Yu

    2017-11-01

    Growth of nanostructured fuzz on a tungsten target in a helium plasma is found to cause a significant (~3×) reduction in ion impact secondary electron emission in a linear plasma device. The ion impact secondary electron emission is separated from the electron impact secondary electron emission by varying the target bias voltage and fitting to expected contributions from electron impact, both thermal and non-thermal; with the non-thermal electron contribution being modeled using Monte-Carlo simulations. The observed (~3×) reduction is similar in magnitude to the (~2×) reduction observed in previous work for the effect of tungsten fuzz formation on secondary electron emission due to electron impact. It is hypothesized that the observed reduction results from re-absorption of secondary electrons in the tungsten fuzz.

  5. Optical properties of planar waveguides on ZnWO₄ formed by carbon and helium ion implantation and effects of annealing.

    Science.gov (United States)

    Zhao, Jin-Hua; Liu, Tao; Guo, Sha-Sha; Guan, Jing; Wang, Xue-Lin

    2010-08-30

    We report on the optical properties of ZnWO(4) planar waveguides created by ion implantation, and the effect annealing has on these structures. Planar optical waveguides in ZnWO(4) crystals are fabricated by 5.0 MeV carbon ion implantation with a fluence of 1 × 10(15) ions/cm(2) or 500 keV helium ion implantation with the a fluence of 1 × 10(16) ions/cm(2). The thermal stability was investigated by 60 minute annealing cycles at different temperatures ranging from 260°C to 550°C in air. The guided modes were measured by a model 2010 prism coupler at wavelengths of 633 nm and 1539 nm. The reflectivity calculation method (RCM) was applied to simulate the refractive index profile in these waveguides. The near-field light intensity profiles were measured using the end-face coupling method. The absorption spectra show that the implantation processes have almost no influence on the visible band absorption.

  6. Heavy metal incorporated helium ion active hybrid non-chemically amplified resists: Nano-patterning with low line edge roughness

    Science.gov (United States)

    Reddy, Pulikanti Guruprasad; Thakur, Neha; Lee, Chien-Lin; Chien, Sheng-Wei; Pradeep, Chullikkattil P.; Ghosh, Subrata; Tsai, Kuen-Yu; Gonsalves, Kenneth E.

    2017-08-01

    Helium (He) ion lithography is being considered as one of the most promising and emerging technology for the manufacturing of next generation integrated circuits (ICs) at nanolevel. However, He-ion active resists are rarely reported. In this context, we are introducing a new non-chemically amplified hybrid resist (n-CAR), MAPDSA-MAPDST, for high resolution He-ion beam lithography (HBL) applications. In the resist architecture, 2.15 % antimony is incorporated as heavy metal in the form of antimonate. This newly developed resists has successfully used for patterning 20 nm negative tone features at a dose of 60 μC/cm2. The resist offered very low line edge roughness (1.27±0.31 nm) for 20 nm line features. To our knowledge, this is the first He-ion active hybrid resist for nanopatterning. The contrast (γ) and sensitivity (E0) of this resist were calculated from the contrast curve as 0.73 and 7.2 μC/cm2, respectively.

  7. Heavy metal incorporated helium ion active hybrid non-chemically amplified resists: Nano-patterning with low line edge roughness

    Directory of Open Access Journals (Sweden)

    Pulikanti Guruprasad Reddy

    2017-08-01

    Full Text Available Helium (He ion lithography is being considered as one of the most promising and emerging technology for the manufacturing of next generation integrated circuits (ICs at nanolevel. However, He-ion active resists are rarely reported. In this context, we are introducing a new non-chemically amplified hybrid resist (n-CAR, MAPDSA-MAPDST, for high resolution He-ion beam lithography (HBL applications. In the resist architecture, 2.15 % antimony is incorporated as heavy metal in the form of antimonate. This newly developed resists has successfully used for patterning 20 nm negative tone features at a dose of 60 μC/cm2. The resist offered very low line edge roughness (1.27±0.31 nm for 20 nm line features. To our knowledge, this is the first He-ion active hybrid resist for nanopatterning. The contrast (γ and sensitivity (E0 of this resist were calculated from the contrast curve as 0.73 and 7.2 μC/cm2, respectively.

  8. Dynamic correlation in the electron angular distribution in ionization of helium by ion impact

    Energy Technology Data Exchange (ETDEWEB)

    Monti, J M; Fojon, O A; Rivarola, R D [Instituto de Fisica Rosario (CONICET-UNR) and Facultad de Ciencias Exactas, IngenierIa y Agrimensura, Universidad Nacional de Rosario, Avenida Pellegrini 250, 2000 Rosario (Argentina); Hanssen, J, E-mail: rivarola@fceia.unr.edu.ar [Institut de Chimie, Physique et Materiaux, Laboratoire de Physique Moleculaire et des Collisions, Universite Paul Verlaine - Metz, 1 Bv. Arago, 57078 Metz Cedex 3 (France)

    2011-04-01

    Single ionization of helium by proton impact is investigated in terms of a four-body distorted wave model. In this approximation both electrons are considered as active, being one of them ionized whereas the other remains in a residual target bound state. The influence of dynamic correlation between electrons is investigated by comparison with a four-body uncorrelated distorted wave model. Double differential cross sections as a function of the emission angle for fixed electron energies and different collision energies are presented.

  9. Measurement of track structure parameters of low and medium energy helium and carbon ions in nanometric volumes

    Science.gov (United States)

    Hilgers, G.; Bug, M. U.; Rabus, H.

    2017-10-01

    Ionization cluster size distributions produced in the sensitive volume of an ion-counting wall-less nanodosimeter by monoenergetic carbon ions with energies between 45 MeV and 150 MeV were measured at the TANDEM-ALPI ion accelerator facility complex of the LNL-INFN in Legnaro. Those produced by monoenergetic helium ions with energies between 2 MeV and 20 MeV were measured at the accelerator facilities of PTB and with a 241Am alpha particle source. C3H8 was used as the target gas. The ionization cluster size distributions were measured in narrow beam geometry with the primary beam passing the target volume at specified distances from its centre, and in broad beam geometry with a fan-like primary beam. By applying a suitable drift time window, the effective size of the target volume was adjusted to match the size of a DNA segment. The measured data were compared with the results of simulations obtained with the PTB Monte Carlo code PTra. Before the comparison, the simulated cluster size distributions were corrected with respect to the background of additional ionizations produced in the transport system of the ionized target gas molecules. Measured and simulated characteristics of the particle track structure are in good agreement for both types of primary particles and for both types of the irradiation geometry. As the range in tissue of the ions investigated is within the typical extension of a spread-out Bragg peak, these data are useful for benchmarking not only ‘general purpose’ track structure simulation codes, but also treatment planning codes used in hadron therapy. Additionally, these data sets may serve as a data base for codes modelling the induction of radiation damages at the DNA-level as they almost completely characterize the ionization component of the nanometric track structure.

  10. Helium implantation induced metal gettering in silicon at half of the projected ion range

    Science.gov (United States)

    Peeva, A.; Fichtner, P. F. P.; Behar, M.; Koegler, R.; Skorupa, W.

    2001-04-01

    Damage has been found in 40 keV He + ion-implanted Si away from the projected ion range Rp, mainly around Rp/2. Cu gettering has been used for detecting implantation induced defects which are formed during rapid thermal annealing (RTA) of 800°C/10 min. Transmission electron microscopy (TEM) micrographs show no visible defects at Rp/2. The Cu gettering peak at Rp/2 is well known for MeV-ion-implanted and annealed Si ( Rp/2 effect). In this study, the corresponding effect is observed for low-energy implantation of a light ion-like He.

  11. Damage of alumina films by medium energy hydrogen and helium ions

    CERN Document Server

    Bailey, P; Liu, Y; Alexander, M R; Koroleva, E V; Skeldon, P; Thompson, G E; Habazaki, H; Shimizu, K

    2002-01-01

    Following previous observations of detachment of amorphous, anodic alumina films from aluminium by 100 keV H sup + ions, further experiments have been carried out using H sup + , D sup + , sup 3 He sup + and sup 4 He sup + ions, at energies in the range of 0.5-270 keV, to irradiate anodized aluminium with oxides of thickness from 30 to 500 nm. Surface damage was investigated by field-emission-gun scanning electron microscopy and transmission electron microscopy. Detachment of the oxide, which takes place close to, or at, the metal/oxide interface, occurred only following irradiation by H sup + and D sup + ions, with the ions being stopped in the metal rather than the oxide. The threshold fluence for initiation of detachment is approximately 3x10 sup 1 sup 5 ions cm sup - sup 2. No detachment was detected following irradiations by sup 3 He sup + and sup 4 He sup + ions with fluences up to 5x10 sup 1 sup 6 ions cm sup - sup 2 and ranges similar to those of H sup + and D sup + ions, although vacancy production i...

  12. Simultaneous quiet time observations of energetic radiation belt protons and helium ions - The equatorial alpha/p ratio near 1 MeV

    Science.gov (United States)

    Fritz, T. A.; Spjeldvik, W. N.

    1979-01-01

    Simultaneous monitoring of energetic helium ions and protons in the earth's radiation belts has been conducted with Explorer 45 in the immediate vicinity of the equatorial plane. Protons were measured from less than 1 keV to 1.6 MeV and also above 3.3 MeV in a channel responsive up to 22 MeV; helium ions were monitored in three passbands: 910 keV to 3.15 MeV, 590 to 910 keV, and 2.0 to 3.99 MeV. Alpha/proton flux ratios were found to vary significantly with energy and location in the radiation belts. At equal energy per nucleon a range of variability for alpha/p from 0.0001 to well above 0.001 was found, and at equal energy per ion the corresponding variability was from 0.001 to above 10. The latter findings emphasize the relative importance of the very energetic helium ions in the overall radiation belt ion populations.

  13. Charge stripping of ^{238}U ion beam by helium gas stripper

    National Research Council Canada - National Science Library

    Imao, H; Okuno, H; Kuboki, H; Yokouchi, S; Fukunishi, N; Kamigaito, O; Hasebe, H; Watanabe, T; Watanabe, Y; Kase, M; Yano, Y

    2012-01-01

    Development of a nondestructive, efficient electric-charge-stripping method is a key requirement for next-generation high-intensity heavy-ion accelerators such as the RIKEN Radioactive-Isotope Beam Factory...

  14. Ultra-precise single-ion atomic mass measurements on deuterium and helium-3

    Science.gov (United States)

    Zafonte, S. L.; Van Dyck, R. S., Jr.

    2015-04-01

    The former University of Washington Penning Trap Mass Spectrometer (UW-PTMS), now located at the Max Planck Institute for Nuclear Physics in Heidelberg, Germany, was used in the decade before the move to determine new values for the deuteron atomic mass, M (2H+) = 2.013 553 212 745(40) u, and the deuterium atomic mass, M (2H) = 2.014 101 778 052(40) u, both of which are now more than an order-of-magnitude more accurate than the previous best 1994-MIT measurements of these quantities. The new value for the deuteron’s mass can then be used with the accepted 2010-CODATA proton mass and the most recent 1999-measurement of the 2.2 MeV gamma-ray binding energy of the deuteron to refine the neutron’s mass to mn = 1.008 664 916 018(435) u which has about half the uncertainty relative to the value computed using that previous 1994-MIT deuterium measurement. As a result, further improvements of mn must now come from a more accurate determination of the wavelength of this gamma ray. In this same period of time, this spectrometer has also been used to determine new values for the helion atomic mass, M (3He2+) = 3.014 932 246 668(43) u, and the neutral helium-3 atomic mass, M (3He) = 3.016 029 321 675(43) u, which are both about 60 times more accurate than the 2006-SMILETRAP measurements, but disagree with the 4.4-times less-accurate 2015-Florida-State measurements by 0.76 nu. It is expected that these helium-3 results will be used in the future 3H/3He mass ratio (to be determined by the Heidelberg, Germany version of the old UW-PTMS) in order to generate a more accurate value for the tritium atomic mass.

  15. Toward plasmonics with nanometer precision: nonlinear optics of helium-ion milled gold nanoantennas.

    Science.gov (United States)

    Kollmann, Heiko; Piao, Xianji; Esmann, Martin; Becker, Simon F; Hou, Dongchao; Huynh, Chuong; Kautschor, Lars-Oliver; Bösker, Guido; Vieker, Henning; Beyer, André; Gölzhäuser, Armin; Park, Namkyoo; Vogelgesang, Ralf; Silies, Martin; Lienau, Christoph

    2014-08-13

    Plasmonic nanoantennas are versatile tools for coherently controlling and directing light on the nanoscale. For these antennas, current fabrication techniques such as electron beam lithography (EBL) or focused ion beam (FIB) milling with Ga(+)-ions routinely achieve feature sizes in the 10 nm range. However, they suffer increasingly from inherent limitations when a precision of single nanometers down to atomic length scales is required, where exciting quantum mechanical effects are expected to affect the nanoantenna optics. Here, we demonstrate that a combined approach of Ga(+)-FIB and milling-based He(+)-ion lithography (HIL) for the fabrication of nanoantennas offers to readily overcome some of these limitations. Gold bowtie antennas with 6 nm gap size were fabricated with single-nanometer accuracy and high reproducibility. Using third harmonic (TH) spectroscopy, we find a substantial enhancement of the nonlinear emission intensity of single HIL-antennas compared to those produced by state-of-the-art gallium-based milling. Moreover, HIL-antennas show a vastly improved polarization contrast. This superior nonlinear performance of HIL-derived plasmonic structures is an excellent testimonial to the application of He(+)-ion beam milling for ultrahigh precision nanofabrication, which in turn can be viewed as a stepping stone to mastering quantum optical investigations in the near-field.

  16. A liquid-helium-free superconducting coil system forming a flat minimum-magnetic-field distribution of an electron cyclotron resonance ion source.

    Science.gov (United States)

    Yoshida, Ken-ichi; Nara, Takayuki; Saitoh, Yuichi; Yokota, Watalu

    2014-02-01

    A flat distribution of the minimum magnetic field (flat-Bmin) of an electron cyclotron resonance ion source (ECRIS) is expected to perform better in highly charged ion production than classical Bmin. To form a flat-Bmin structure with a liquid helium-free superconducting device, a coil system of seven coils with four current leads has been designed. The lead number was reduced by connecting the plural coils in series to maintain the flat-Bmin structure even when the coil currents are changed for adjustment. This coil system can be operated with a helium-free cryostat, since the estimation of heat from the leads to the coils is nearly equivalent to the existing superconducting ECRIS of a similar type.

  17. A liquid-helium-free superconducting coil system forming a flat minimum-magnetic-field distribution of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Ken-ichi, E-mail: yoshida.kennichi71@jaea.go.jp; Nara, Takayuki; Saitoh, Yuichi; Yokota, Watalu [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-02-15

    A flat distribution of the minimum magnetic field (flat-B{sub min}) of an electron cyclotron resonance ion source (ECRIS) is expected to perform better in highly charged ion production than classical B{sub min}. To form a flat-B{sub min} structure with a liquid helium-free superconducting device, a coil system of seven coils with four current leads has been designed. The lead number was reduced by connecting the plural coils in series to maintain the flat-B{sub min} structure even when the coil currents are changed for adjustment. This coil system can be operated with a helium-free cryostat, since the estimation of heat from the leads to the coils is nearly equivalent to the existing superconducting ECRIS of a similar type.

  18. A liquid-helium-free superconducting coil system forming a flat minimum-magnetic-field distribution of an electron cyclotron resonance ion source

    Science.gov (United States)

    Yoshida, Ken-ichi; Nara, Takayuki; Saitoh, Yuichi; Yokota, Watalu

    2014-02-01

    A flat distribution of the minimum magnetic field (flat-Bmin) of an electron cyclotron resonance ion source (ECRIS) is expected to perform better in highly charged ion production than classical Bmin. To form a flat-Bmin structure with a liquid helium-free superconducting device, a coil system of seven coils with four current leads has been designed. The lead number was reduced by connecting the plural coils in series to maintain the flat-Bmin structure even when the coil currents are changed for adjustment. This coil system can be operated with a helium-free cryostat, since the estimation of heat from the leads to the coils is nearly equivalent to the existing superconducting ECRIS of a similar type.

  19. Use of accelerated helium-3 ions for determining oxygen and carbon impurities in some pure materials

    Science.gov (United States)

    Aleksandrova, G. I.; Borisov, G. I.; Demidov, A. M.; Zakharov, Y. A.; Sukhov, G. V.; Shmanenkova, G. I.; Shchelkova, V. P.

    1978-01-01

    Methods are developed for the determination of O impurity in Be and Si carbide and concurrent determination of C and O impurities in Si and W by irradiation with accelerated He-3 ions and subsequent activity measurements of C-11 and F-18 formed from C and O with the aid of a gamma-gamma coincidence spectrometer. Techniques for determining O in Ge and Ga arsenide with radiochemical separation of F-18 are also described.

  20. Ultrafast third-harmonic spectroscopy of single nanoantennas fabricated using helium-ion beam lithography

    Science.gov (United States)

    Kollmann, H.; Esmann, M.; Becker, S. F.; Piao, X.; Huynh, C.; Kautschor, L.-O.; Bösker, G.; Vieker, H.; Beyer, A.; Gölzhäuser, A.; Park, N.; Silies, M.; Lienau, C.

    2016-03-01

    Metallic nanoantennas are able to spatially localize far-field electromagnetic waves on a few nanometer length scale in the form of surface plasmon excitations 1-3. Standard tools for fabricating bowtie and rod antennas with sub-20 nm feature sizes are Electron Beam Lithography or Ga-based Focused Ion Beam (FIB) Milling. These structures, however, often suffer from surface roughness and hence show only a limited optical polarization contrast and therefore a limited electric field localization. Here, we combine Ga- and He-ion based milling (HIM) for the fabrication of gold bowtie and rod antennas with gap sizes of less than 6 nm combined with a high aspect ratio. Using polarization-sensitive Third-Harmonic (TH) spectroscopy, we compare the nonlinear optical properties of single HIM-antennas with sub-6-nm gaps with those produced by standard Ga-based FIB. We find a pronounced enhancement of the total TH intensity of more than three in comparison to Ga-FIB antennas and a highly improved polarization contrast of the TH intensity of 250:1 for Heion produced antennas 4. These findings combined with Finite-Element Method calculations demonstrate a field enhancement of up to one hundred in the few-nanometer gap of the antenna. This makes He-ion beam milling a highly attractive and promising new tool for the fabrication of plasmonic nanoantennas with few-nanometer feature sizes.

  1. Bubbles formation in helium ion irradiated Cu/W multilayer nanocomposites: Effects on structure and mechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Callisti, M., E-mail: M.Callisti@soton.ac.uk [National Centre for Advanced Tribology at Southampton, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom); Karlik, M. [Department of Materials, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Trojanova 13, 120 00 Prague 2 (Czech Republic); Polcar, T. [National Centre for Advanced Tribology at Southampton, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom); Department of Control Engineering, Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, 16627 Prague 6 (Czech Republic)

    2016-05-15

    This study investigates the effects of He bubbles on structural and mechanical properties of sputter-deposited Cu/W multilayers. A multilayer with a periodicity of 10 nm was deposited and subjected to helium ion irradiation with two different fluences. He bubbles formed mostly in Cu layers and their distribution was affected by He concentration and radiation damage. According to SRIM calculations, in low He concentration regions bubbles formed mostly along interfaces, while more homogeneously distributed bubbles were found in Cu layers and along columnar grain boundaries in higher He concentration regions. We suggest that the capability of interfaces to annihilate point defects is weakened by the He bubbles shielding effect. Nanoindentation tests revealed a hardness decrease amounting to ∼0.5 and ∼1 GPa for low and high fluences, respectively. The observed softening effect is attributed to He storage-induced changes in residual stresses and columnar grain boundary/interfacial sliding facilitated by He bubbles. - Highlights: • Cu/W nanocomposites were subjected to He{sup +} irradiation with different fluences. • He bubbles formed more homogeneously in higher He concentration regions. • Decrease in mechanical properties was observed for higher He concentrations. • He bubbles formation facilitated interfacial and grain boundary sliding.

  2. Cryptoendolithic Antarctic Black Fungus Cryomyces antarcticus Irradiated with Accelerated Helium Ions: Survival and Metabolic Activity, DNA and Ultrastructural Damage

    Directory of Open Access Journals (Sweden)

    Claudia Pacelli

    2017-10-01

    Full Text Available Space represents an extremely harmful environment for life and survival of terrestrial organisms. In the last decades, a considerable deal of attention was paid to characterize the effects of spaceflight relevant radiation on various model organisms. The aim of this study was to test the survival capacity of the cryptoendolithic black fungus Cryomyces antarcticus CCFEE 515 to space relevant radiation, to outline its endurance to space conditions. In the frame of an international radiation campaign, dried fungal colonies were irradiated with accelerated Helium ion (150 MeV/n, LET 2.2 keV/μm, up to a final dose of 1,000 Gy, as one of the space-relevant ionizing radiation. Results showed that the fungus maintained high survival and metabolic activity with no detectable DNA and ultrastructural damage, even after the highest dose irradiation. These data give clues on the resistance of life toward space ionizing radiation in general and on the resistance and responses of eukaryotic cells in particular.

  3. Measurement of ion beam angular distribution at different helium gas pressures in a plasma focus device by large-area polycarbonate detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sohrabi, M.; Habibi, M., E-mail: mortezahabibi@gmail.com; Ramezani, V. [Amirkabir University of Technology, Energy Engineering and Physics Department (Iran, Islamic Republic of)

    2017-02-15

    The paper presents an experimental study and analysis of full helium ion density angular distributions in a 4-kJ plasma focus device (PFD) at pressures of 10, 15, 25, and 30 mbar using large-area polycarbonate track detectors (PCTDs) (15-cm etchable diameter) processed by 50-Hz-HV electrochemical etching (ECE). Helium ion track distributions at different pressures, in particular, at the main axis of the PFD are presented. Maximum ion track density of ~4.4 × 10{sup 4} tracks/cm{sup 2} was obtained in the PCTD placed 6 cm from the anode. The ion distributions for all pressures applied are ring-shaped, which is possibly due to the hollow cylindrical copper anode used. The large-area PCTD processed by ECE proves, at the present state-of-theart, a superior method for direct observation and analysis of ion distributions at a glance with minimum efforts and time. Some observations of the ion density distributions at different pressures are reported and discussed.

  4. Radiation chemical behavior of aqueous butanal oxime solutions irradiated with helium ion beams

    Science.gov (United States)

    Costagliola, A.; Venault, L.; Deroche, A.; Garaix, G.; Vermeulen, J.; Omnee, R.; Duval, F.; Blain, G.; Vandenborre, J.; Fattahi-Vanani, M.; Vigier, N.

    2016-02-01

    Samples of butanal oxime in aqueous solution have been irradiated with the helion (4He2+) beam of the ARRONAX (Nantes) and the CEMHTI (Orléans) cyclotrons. The consumption yield of butanal oxime has been measured by gas-chromatography coupled with mass spectrometry. Yields of gaseous products (mainly H2) have also been measured by micro-gas-chromatography. Butanal oxime can react with H• radicals by abstraction mechanism to enhance H2 production. Yields of liquid phase products (hydrogen peroxide and nitrite ion) have been measured by colorimetric methods. Butanal oxime acts as a scavenger of OH• radical to inhibit the production of H2O2. The observation of the radiolytic products allows then to discuss a degradation mechanism of butanal oxime in aqueous solutions.

  5. Atom probe field ion microscope study of the range and diffusivity of helium in tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, A.

    1978-08-01

    A time-of-flight (TOF) atom-probe field-ion microscope (FIM) specifically designed for the study of defects in metals is described. With this automated system 600 TOF min/sup -1/ can be recorded and analyzed. Performance tests of the instrument demonstrated that (1) the seven isotopes of molybdenum and the five isotopes of tungsten can be clearly resolved; and (2) the concentration and spatial distribution of all constitutents present at levels greater than 0.05 at. % in a W--25 at. % Re, Mo--1.0 at. % Ti, Mo--1.0 at. % Ti--0.08 at. % Zr (TZM), a low swelling stainless steel (LS1A) and a metallic glass (Metglas 2826) can be measured. The effect of the rate of field evaporation on the quantitative atom probe analysis of a Mo--1.0 at. % Ti alloy and a Mo--1.0 at. % Ti--0.08 at. % Zr alloy was investigated. As the field evaporation rate increased the measured Ti concentration was found to also increase. A simple qualitative model was proposed to explain the observation. The spatial distribution of titanium in a fast neutron irradiated Mo--1.0 at. % Ti alloy has been investigated. No evidence of Ti segregation to the voids was detected nor has any evidence of significant resolution of Ti from the TiC precipitates been detected. A small amount of segregation of carbon to a void was detected.

  6. Differential and total cross sections for charge transfer and transfer-excitation in ion-helium collisions

    Science.gov (United States)

    Halder, S.; Mondal, A.; Samaddar, S.; Mandal, C. R.; Purkait, M.

    2017-09-01

    Total cross sections for single charge transfer in collisions of multicharged bare ions with ground-state helium atoms at incident energy ranging from 40 to 5000 keV/amu have been calculated in the framework of a four-body model of final channel distorted-wave (FC-DW-4B) approximation. In this formalism, distortion in the final channel related to the Coulomb continuum of the target and the Coulomb interaction between the passive electron in the target with the projectile are included. In all cases, total single electron-capture cross sections have been calculated by summing over all contributions up to n =3 shells and subshells. It has been observed that the contribution of the capture cross sections into excited states have insignificant contributions for symmetric collisions. Comprehensive comparisons are made between the four body model of boundary corrected continuum intermediate-state approximations [Phys. Rev. A 83, 032706 (2011), 10.1103/PhysRevA.83.032706] and the present FC-DW-4B model. The main purpose of the present study is to investigate the relative importance of dynamic electron correlation and the role of passive electron in the target at intermediate and high impact energies. In addition, projectile angular differential cross sections (DCS) for charge transfer and transfer-excitation in p -He collisions are calculated at different impact energies. At low projectile energies, the present DCS data exhibits the typical steeply decreasing dependence on the projectile scattering angles, whereas at high impact energies, the double-scattering region centered on the Thomas angle is obtained. Detailed comparisons with the available experimental data and other theories are reported with the purpose of further assessing the relevance of the present model at different impact energies. Overall, the calculated cross sections show good agreement with the available experimental findings.

  7. Klare Regeln - effiziente und effektive FMEA-Anwendung

    OpenAIRE

    Schloske, Alexander

    2014-01-01

    Der Vortrag beschreibt klare Regeln zur effizienten und effektiven FMEA-Anwendung. - Denkmodelle für die verschiedenen FMEA-Arten (System-FMEA, Konstruktions-FMEA, Prozess-FMEA) - Anwendungsbereiche und FMEA-Planung - Strukturierung von FMEAs - Funktionen, Produktmerkmale und Prozessmerkmale - Risikoanalyse - Maßnahmendefinition - Risikobewertung - Präsentation von FMEAs - FMEA als "lebendes Dokument".

  8. Liquid helium

    CERN Document Server

    Atkins, K R

    1959-01-01

    Originally published in 1959 as part of the Cambridge Monographs on Physics series, this book addresses liquid helium from the dual perspectives of statistical mechanics and hydrodynamics. Atkins looks at both Helium Three and Helium Four, as well as the properties of a combination of the two isotopes. This book will be of value to anyone with an interest in the history of science and the study of one of the universe's most fundamental elements.

  9. Selective area growth of InAs nanowires from SiO2/Si(1 1 1) templates direct-written by focused helium ion beam technology

    Science.gov (United States)

    Yang, Che-Wei; Chen, Wei-Chieh; Chou, Chieh; Lin, Hao-Hsiung

    2018-02-01

    We report on the selective area growth of InAs nanowires on patterned SiO2/Si (1 1 1) nano-holes, prepared by focused helium ion beam technology. We used a single spot mode, in which the focused helium ion beam was fixed on a single point with a He+-ion dosage, ranging from 1.5 pC to 8 pC, to drill the nano-holes. The smallest hole diameter achieved is ∼8 nm. We found that low He+-ion dosage is able to facilitate the nucleation of (1 1 1)B InAs on the highly mismatched Si, leading to the vertical growth of InAs nanowires (NWs). High He-ion dosage, on the contrary, severely damaged Si surface, resulting in tilted and stripe-like NWs. In addition to titled NW grown from (1 1 1)A InAs domain, a new titled growth direction due to defect induced twinning was observed. Cross-sectional TEM images of vertical NWs show mixed wurtizite (WZ) and zincblende (ZB) phases, while WZ phase dominants. The stacking faults resulting from the phase change is proportional to NW diameter, suggesting that the critical diameter of phase turning is larger than 110 nm, the maximum diameter of our NWs. Period of misfit dislocation at the InAs/Si interface of vertical NW is also found larger than the theoretical value when the diameter of heterointerface is smaller than 50 nm, indicating that the small contact area is able to accommodate the large lattice and thermal mismatch between InAs and Si.

  10. Effects of indirect actions and oxygen on relative biological effectiveness: estimate of DSB induction and conversion induced by gamma rays and helium ions

    Science.gov (United States)

    Tsai, Ju-Ying; Chen, Fang-Hsin; Hsieh, Tsung-Yu; Hsiao, Ya-Yun

    2015-01-01

    Clustered DNA damage other than double-strand breaks (DSBs) can be detrimental to cells and can lead to mutagenesis or cell death. In addition to DSBs induced by ionizing radiation, misrepair of non-DSB clustered damage contributes extra DSBs converted from DNA misrepair via pathways for base excision repair and nucleotide excision repair. This study aimed to quantify the relative biological effectiveness (RBE) when DSB induction and conversion from non-DSB clustered damage misrepair were used as biological endpoints. The results showed that both linear energy transfer (LET) and indirect action had a strong impact on the yields for DSB induction and conversion. RBE values for DSB induction and maximum DSB conversion of helium ions (LET = 120 keV/μm) to 60Co gamma rays were 3.0 and 3.2, respectively. These RBE values increased to 5.8 and 5.6 in the absence of interference of indirect action initiated by addition of 2-M dimethylsulfoxide. DSB conversion was ∼1–4% of the total non-DSB damage due to gamma rays, which was lower than the 10% estimate by experimental measurement. Five to twenty percent of total non-DSB damage due to helium ions was converted into DSBs. Hence, it may be possible to increase the yields of DSBs in cancerous cells through DNA repair pathways, ultimately enhancing cell killing. PMID:25902742

  11. submitter Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams

    CERN Document Server

    Dokic, Ivana; Niklas, Martin; Zimmermann, Ferdinand; Chaudhri, Naved; Krunic, Damir; Tessonnier, Thomas; Ferrari, Alfredo; Parodi, Katia; Jäkel, Oliver; Debus, Jürgen; Haberer, Thomas; Abdollahi, Amir

    2016-01-01

    The growing number of particle therapy facilities worldwide landmarks a novel era of precision oncology. Implementation of robust biophysical readouts is urgently needed to assess the efficacy of different radiation qualities. This is the first report on biophysical evaluation of Monte Carlo simulated predictive models of prescribed dose for four particle qualities i.e., proton, helium-, carbon- or oxygen ions using raster-scanning technology and clinical therapy settings at HIT. A high level of agreement was found between the in silico simulations, the physical dosimetry and the clonogenic tumor cell survival. The cell fluorescence ion track hybrid detector (Cell-Fit-HD) technology was employed to detect particle traverse per cell nucleus. Across a panel of radiobiological surrogates studied such as late ROS accumulation and apoptosis (caspase 3/7 activation), the relative biological effectiveness (RBE) chiefly correlated with the radiation species-specific spatio-temporal pattern of DNA double strand break ...

  12. Helium cryogenics

    CERN Document Server

    Van Sciver, Steven W

    2012-01-01

    Twenty five years have elapsed since the original publication of Helium Cryogenics. During this time, a considerable amount of research and development involving helium fluids has been carried out culminating in several large-scale projects. Furthermore, the field has matured through these efforts so that there is now a broad engineering base to assist the development of future projects. Helium Cryogenics, 2nd edition brings these advances in helium cryogenics together in an updated form. As in the original edition, the author's approach is to survey the field of cryogenics with emphasis on helium fluids. This approach is more specialized and fundamental than that contained in other cryogenics books, which treat the associated range of cryogenic fluids. As a result, the level of treatment is more advanced and assumes a certain knowledge of fundamental engineering and physics principles, including some quantum mechanics. The goal throughout the work is to bridge the gap between the physics and engineering aspe...

  13. Antiprotonic helium

    CERN Multimedia

    Eades, John

    2005-01-01

    An exotic atom in w hich an electron and an antiproton orbit a helium nucleus could reveal if there are any differences between matter and antimatter. The author describes this unusual mirror on the antiworld (5 pages)

  14. Effects of indirect actions and oxygen on relative biological effectiveness: estimate of DSB induction and conversion induced by gamma rays and helium ions.

    Science.gov (United States)

    Tsai, Ju-Ying; Chen, Fang-Hsin; Hsieh, Tsung-Yu; Hsiao, Ya-Yun

    2015-07-01

    Clustered DNA damage other than double-strand breaks (DSBs) can be detrimental to cells and can lead to mutagenesis or cell death. In addition to DSBs induced by ionizing radiation, misrepair of non-DSB clustered damage contributes extra DSBs converted from DNA misrepair via pathways for base excision repair and nucleotide excision repair. This study aimed to quantify the relative biological effectiveness (RBE) when DSB induction and conversion from non-DSB clustered damage misrepair were used as biological endpoints. The results showed that both linear energy transfer (LET) and indirect action had a strong impact on the yields for DSB induction and conversion. RBE values for DSB induction and maximum DSB conversion of helium ions (LET = 120 keV/μm) to (60)Co gamma rays were 3.0 and 3.2, respectively. These RBE values increased to 5.8 and 5.6 in the absence of interference of indirect action initiated by addition of 2-M dimethylsulfoxide. DSB conversion was ∼1-4% of the total non-DSB damage due to gamma rays, which was lower than the 10% estimate by experimental measurement. Five to twenty percent of total non-DSB damage due to helium ions was converted into DSBs. Hence, it may be possible to increase the yields of DSBs in cancerous cells through DNA repair pathways, ultimately enhancing cell killing. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  15. Production of doubly charged helium ions by two-photon absorption of an intense sub-10-fs soft x-ray pulse at 42 eV photon energy.

    Science.gov (United States)

    Nabekawa, Yasuo; Hasegawa, Hirokazu; Takahashi, Eiji J; Midorikawa, Katsumi

    2005-02-04

    We report on the observation of doubly charged helium ions produced by a nonlinear interaction between a helium atom and photons with a photon energy of 42 eV which are generated with the 27th harmonic of a femtosecond pulse from a Ti:sapphire laser. The number of ions is proportional to the square of the intensity of the 27th harmonic pulse, and thus two-photon double ionization should be dominantly induced as compared with other nonlinear processes accompanying sequential ionization via a singly charged ion. This phenomenon is utilized to measure the pulse duration of the 27th harmonic pulse by using an autocorrelation technique, for the first time to our knowledge, and as a result a duration of 8 fs is found.

  16. SU-E-T-539: Maximum Energy of Helium and Carbon Ions Clinically Needed for Spine, Lung, Prostate and Pancreas Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pompos, A; Choy, H; Jia, X; Jiang, S; Timmerman, R [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States)

    2015-06-15

    Purpose: Maximum available kinetic energy of accelerated heavy ions is a critical parameter to consider during the establishment of a heavy ion therapy center. It dictates the maximum range in tissue and determines the size and cost of ion gantry. We have started planning our heavy ion therapy center and we report on the needed ion range. Methods: We analyzed 50 of random SBRT-spine, SBRT- lung, prostate and pancreatic cancer patients from our photon clinic. In the isocentric axial CT cut we recorded the maximum water equivalent depth (WED4Field) of PTV’s most distal edge in four cardinal directions and also in a beam direction that required the largest penetration, WEDGantry. These depths were then used to calculate the percentage of our patients we would be able to treat as a function of available maximum carbon and helium beam energy. Based on the Anterior-Posterior WED for lung patients and the maximum available ion energy we estimated the largest possible non-coplanar beam entry angle φ (deviation from vertical) in the isocentric vertical sagittal plane. Results: We found that if 430MeV/u C-12, equivalently 220MeV/u He-4, beams are available, more than 96% (98%) of all patients can be treated without any gantry restrictions (in cardinals angles only) respectively. If the energy is reduced to 400MeV/u C-12, equivalently 205MeV/u He-4, the above fractions reduce to 80% (87%) for prostate and 88% (97%) for other sites. This 7% energy decrease translates to almost 5% gantry size and cost decrease for both ions. These energy limits in combination with the WED in the AP direction for lung patients resulted in average non-coplanar angles of φ430MeV/u = 68°±8° and φ400MeV/u = 65°±10° if nozzle clearance permits them. Conclusion: We found that the two worldwide most common maximum carbon beam energies will treat above 80% of all our patients.

  17. Effect of dual ion beam irradiation (helium and deuterium on tungsten–tantalum alloys under fusion relevant conditions

    Directory of Open Access Journals (Sweden)

    S. Gonderman

    2017-08-01

    Full Text Available The selection of tungsten (W as a divertor material in ITER is based on its high melting point, low erosion, and strong mechanical properties. However, continued investigation has shown W to undergo severe morphology changes in fusion-like conditions. Recent literature suggests alloying W with other ductile refractory metals, viz. tantalum (Ta may resolve some of these issues. These results provide further motivation for investigating W–Ta alloys as a plasma-facing component (PFC for ITER and future DEMO reactors. Specifically, how these alloy materials respond to simultaneous He+ and D+ ion irradiation, and what is the effect on the surface morphology when exposed to fusion relevant conditions. In the present study, the surface morphology changes are investigated in several W–Ta targets (pure W, W-1%Ta, W-3%Ta, and W-5% Ta due to simultaneous He+ and D+ ion irradiations. This comprehensive work allows for deeper understanding of the synergistic effects induced by dual ion irradiation on W and W–Ta alloy surface morphology. Pure W and W–Ta alloys were irradiated simultaneously by 100eV He+ and/or D+ ions at various mixture ratios (100% He+, 60% D+ + 40% He+, 90% D+ + 10% He+ ions and 100% D+ ions, having a total constant He fluence of 6×1024 ion m−2, and at a target temperature of 1223K. This work shows that slight changes in materials composition and He/D content have significant impact on surface morphology evolution and performance. While both the pure W and W–Ta alloys exhibit very damaged surfaces under the He+ only irradiations, there is a clear suppression of the surface morphology evolution as the ratio of D+/He+ ions is increased.

  18. Ionoluminescence properties of polystyrene-hosted fluorophore films induced by helium ions of energy 50-350 keV

    Science.gov (United States)

    Chakraborty, Subha; Huang, Mengbing

    2017-10-01

    We report on measurements and analysis of ionoluminescence properties of pure polystyrene films and polystyrene films doped with four types of fluorophores in low kinetic energies (50-350 keV) of ion irradiation. We have developed a theoretical model to understand the experimentally observed ionoluminescence behaviors in terms of scintillation yield from individual ion tracks, photophysical energy transfer mechanisms, and irradiation-induced defects. A comparison of the model and experimental results suggests that singlet up-conversion resulting from triplet-triplet annihilation processes may be responsible for enhanced singlet emission of the fluorophores at high ion beam flux densities. Energy transfer from the polystyrene matrix to the fluorophore molecules has been identified as an effective pathway to increasing the fluorescence efficiency in the doped scintillator films.

  19. Helium nanodroplet isolation and infrared spectroscopy of the isolated ion-pair 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide.

    Science.gov (United States)

    Obi, Emmanuel I; Leavitt, Christopher M; Raston, Paul L; Moradi, Christopher P; Flynn, Steven D; Vaghjiani, Ghanshyam L; Boatz, Jerry A; Chambreau, Steven D; Douberly, Gary E

    2013-09-19

    The ionic liquid 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide was vaporized at 420 K, and the ion-pair constituents were entrained in a beam of liquid He nanodroplets and cooled to 0.4 K. The vapor pressure was optimized such that each He droplet picked up a single ion-pair from the gas phase. Infrared spectroscopy in the CH stretch region reveals bands that are assigned to intact ion-pairs on the basis of comparisons to ab initio harmonic frequency computations of 23 low energy isomers. The He droplet spectrum is consistent with a weighted sum of the computed harmonic spectra, in which the weights are determined from ab initio computations of the relative free energies at 420 K. Anharmonic resonance polyads in the CH stretch region are treated explicitly, which improves the agreement between the experiment and computed spectra for ion-pairs. For isomers having a strong cation···anion hydrogen bonding interaction, the imidazolium C(2)-H stretch fundamental is shifted to lower energy and into resonance with the overtones and combination bands of the imidazolium ring stretching modes, resulting in a spectral complexity in the CH stretch region that is fully resolved in the He droplet spectrum. The assignment of the infrared spectrum to ion-pairs is confirmed through polarization spectroscopy measurements that reveal the permanent electric dipole moment of the He-solvated species to be 11 ± 2 D. The computed permanent electric dipole moments for the low energy isomers of the [emim(+)][Tf2N(-)] ion-pairs fall in the range 9-13 D, whereas the computed dipole moments of decomposition products of the ionic liquid are less than 4.3 D.

  20. Helium Nanodroplet Isolation and Infrared Spectroscopy of the Isolated Ion-Pair 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide

    Science.gov (United States)

    2013-09-01

    salts (< 373 K) whose bulky constituents lead to characteristically long cation-anion distances and low lattice energies , in comparison to common ionic...Chen, L. Q.; Hu, Y. S.; Li, H.; Huang, X. J. Novel Room Temperature Molten Salt Electrolyte Based on Litfsi and Acetamide for Lithium Batteries...region reveals bands that are assigned to intact ion-pairs on the basis of comparisons to ab initio harmonic frequency computations of 23 low energy

  1. The modification of the structure of multilayer Co/Pt films by the irradiation with a focused helium ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, S. A., E-mail: gusev@ipmras.ru; Drozdov, M. N.; Ermolaeva, O. L.; Fraerman, A. A.; Gusev, N. S.; Sapozhnikov, M. V., E-mail: msap@ipmras.ru; Vdovichev, S. N. [Institute for Physics of Microstructures RAS, GSP-105, 603950 Nizhny Novgorod (Russian Federation); Mikhailovskii, V. Yu.; Petrov, Yu. V., E-mail: y.petrov@spbu.ru [Saint Petersburg state University, St.Petersburg, Universitetskaya nab. 7/9, 199034 (Russian Federation)

    2016-06-17

    We report here on the possibility of a local modification of Co/Pt multilayered magnetic films by focused ion beam irradiation. The changes of structural and magnetic properties are experimentally investigated as a function of irradiation fluence. The method is used to form lateral structures with the periods up to 100 nm. The magnetic force microscopy accompanied by Hall effect measurements of the structure indicate the formation of magnetic skyrmion lattices in the absence of Dzyaloshinskii-Moriya interaction.

  2. Experimental investigation of the reaction of helium ions with dimethyl ether: stereodynamics of the dissociative charge exchange process.

    Science.gov (United States)

    Cernuto, Andrea; Tosi, Paolo; Martini, Luca Matteo; Pirani, Fernando; Ascenzi, Daniela

    2017-08-02

    The fate of dimethyl ether (DME, CH3OCH3) in collisions with He+ ions is of high relevance for astrochemical models aimed at reproducing the abundances of complex organic molecules in the interstellar medium. Here we report an investigation on the reaction of He+ ions with DME carried out using a Guided Ion Beam Mass Spectrometer (GIB-MS), which allows the measurement of reactive cross-sections and branching ratios (BRs) as a function of the collision energy. We obtain insights into the dissociative charge (electron) exchange mechanism by investigating the nature of the non-adiabatic transitions between the relevant potential energy surfaces (PESs) in an improved Landau-Zener approach. We find that the large interaction anisotropy could induce a pronounced orientation of the polar DME molecule in the electric field generated by He+ so that at short distances the collision complex is confined within pendular states, a particular case of bending motion, which gives rise to intriguing stereodynamic effects. The positions of the intermolecular potential energy curve crossings indicate that He+ captures an electron from an inner valence orbital of DME, thus causing its dissociation. In addition to the crossing positions, the symmetry of the electron density distribution of the involved DME orbitals turns out to be a further major point affecting the probability of electron transfer. Thus, the anisotropy of the intermolecular interaction and the electron densities of the orbitals involved in the reaction are the key "ingredients" for describing the dynamics of this dissociative charge transfer.

  3. Enhanced Radiation-tolerant Oxide Dispersion Strengthened Steel and its Microstructure Evolution under Helium-implantation and Heavy-ion Irradiation

    Science.gov (United States)

    Lu, Chenyang; Lu, Zheng; Wang, Xu; Xie, Rui; Li, Zhengyuan; Higgins, Michael; Liu, Chunming; Gao, Fei; Wang, Lumin

    2017-01-01

    The world eagerly needs cleanly-generated electricity in the future. Fusion reactor is one of the most ideal energy resources to defeat the environmental degradation caused by the consumption of traditional fossil energy. To meet the design requirements of fusion reactor, the development of the structural materials which can sustain the elevated temperature, high helium concentration and extreme radiation environments is the biggest challenge for the entire material society. Oxide dispersion strengthened steel is one of the most popular candidate materials for the first wall/blanket applications in fusion reactor. In this paper, we evaluate the radiation tolerance of a 9Cr ODS steel developed in China. Compared with Ferritic/Martensitic steel, this ODS steel demonstrated a significantly higher swelling resistance under ion irradiation at 460 °C to 188 displacements per atom. The role of oxides and grain boundaries on void swelling has been explored. The results indicated that the distribution of higher density and finer size of nano oxides will lead a better swelling resistance for ODS alloy. The original pyrochlore-structured Y2Ti2O7 particles dissolved gradually while fine Y-Ti-O nano clusters reprecipitated in the matrix during irradiation. The enhanced radiation tolerance is attributed to the reduced oxide size and the increased oxide density.

  4. Helium ion microscopy and ultra-high-resolution scanning electron microscopy analysis of membrane-extracted cells reveals novel characteristics of the cytoskeleton of Giardia intestinalis.

    Science.gov (United States)

    Gadelha, Ana Paula Rocha; Benchimol, Marlene; de Souza, Wanderley

    2015-06-01

    Giardia intestinalis presents a complex microtubular cytoskeleton formed by specialized structures, such as the adhesive disk, four pairs of flagella, the funis and the median body. The ultrastructural organization of the Giardia cytoskeleton has been analyzed using different microscopic techniques, including high-resolution scanning electron microscopy. Recent advances in scanning microscopy technology have opened a new venue for the characterization of cellular structures and include scanning probe microscopy techniques such as ultra-high-resolution scanning electron microscopy (UHRSEM) and helium ion microscopy (HIM). Here, we studied the organization of the cytoskeleton of G. intestinalis trophozoites using UHRSEM and HIM in membrane-extracted cells. The results revealed a number of new cytoskeletal elements associated with the lateral crest and the dorsal surface of the parasite. The fine structure of the banded collar was also observed. The marginal plates were seen linked to a network of filaments, which were continuous with filaments parallel to the main cell axis. Cytoplasmic filaments that supported the internal structures were seen by the first time. Using anti-actin antibody, we observed a labeling in these filamentous structures. Taken together, these data revealed new surface characteristics of the cytoskeleton of G. intestinalis and may contribute to an improved understanding of the structural organization of trophozoites. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Standard Guide for Simulation of Helium Effects in Irradiated Metals

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This guide provides advice for conducting experiments to investigate the effects of helium on the properties of metals where the technique for introducing the helium differs in some way from the actual mechanism of introduction of helium in service. Simulation techniques considered for introducing helium shall include charged particle implantation, exposure to α-emitting radioisotopes, and tritium decay techniques. Procedures for the analysis of helium content and helium distribution within the specimen are also recommended. 1.2 Two other methods for introducing helium into irradiated materials are not covered in this guide. They are the enhancement of helium production in nickel-bearing alloys by spectral tailoring in mixed-spectrum fission reactors, and isotopic tailoring in both fast and mixed-spectrum fission reactors. These techniques are described in Refs (1-5). Dual ion beam techniques (6) for simultaneously implanting helium and generating displacement damage are also not included here. This lat...

  6. Use of double and triple-ion irradiation to study the influence of high levels of helium and hydrogen on void swelling of 8–12% Cr ferritic-martensitic steels

    Energy Technology Data Exchange (ETDEWEB)

    Kupriiyanova, Y.E., E-mail: fomenkoj@kipt.kharkov.ua [National Science Centre Kharkov Institute of Physics and Technology, 1, Akademicheskaya St., Kharkov, 61108 (Ukraine); Bryk, V.V.; Borodin, O.V.; Kalchenko, A.S.; Voyevodin, V.N.; Tolstolutskaya, G.D. [National Science Centre Kharkov Institute of Physics and Technology, 1, Akademicheskaya St., Kharkov, 61108 (Ukraine); Garner, F.A. [Radiation Effects Consulting, Richland, WA 99354 (United States)

    2016-01-15

    In accelerator-driven spallation (ADS) devices, some of the structural materials will be exposed to intense fluxes of very high energy protons and neutrons, producing not only displacement damage, but very high levels of helium and hydrogen. Unlike fission flux-spectra where most helium and hydrogen are generated by transmutation in nickel and only secondarily in iron or chromium, gas production in ADS flux-spectra are rather insensitive to alloy composition, such that Fe–Cr base ferritic alloys also generate very large gas levels. While ferritic alloys are known to swell less than austenitic alloys in fission spectra, there is a concern that high gas levels in fusion and especially ADS facilities may strongly accelerate void swelling in ferritic alloys. In this study of void swelling in response to helium and hydrogen generation, irradiation was conducted on three ferritic-martensitic steels using the Electrostatic Accelerator with External Injector (ESUVI) facility that can easily produce any combination of helium to dpa and/or hydrogen to dpa ratios. Irradiation was conducted under single, dual and triple beam modes using 1.8 MeV Cr{sup +3}, 40 keV He{sup +}, and 20 keV H{sup +}. In the first part of this study we investigated the response of dual-phase EP-450 to variations in He/dpa and H/dpa ratio, focusing first on dual ion studies and then triple ion studies, showing that there is a diminishing influence on swelling with increasing total gas content. In the second part we investigated the relative response of three alloys spanning a range of starting microstructure and composition. In addition to observing various synergisms between He and H, the most important conclusion was that the tempered martensite phase, known to lag behind the ferrite phase in swelling in the absence of gases, loses much of its resistance to void nucleation when irradiated at large gas/dpa levels.

  7. Global helium particle balance in LHD

    Energy Technology Data Exchange (ETDEWEB)

    Motojima, G., E-mail: motojima.gen@lhd.nifs.ac.jp [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Masuzaki, S.; Tokitani, M.; Kasahara, H.; Yoshimura, Y.; Kobayashi, M.; Sakamoto, R.; Morisaki, T.; Miyazawa, J.; Akiyama, T. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Ohno, N. [Graduate School of Engineering, Nagoya University, Nagoya, Aichi 464-8603 (Japan); Mutoh, T.; Yamada, H. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan)

    2015-08-15

    Global helium particle balance in long-pulse discharges is analyzed for the first time in the Large Helical Device (LHD) with the plasma-facing components of the first wall and the divertor tiles composed of stainless steel and carbon, respectively. During the 2-min discharge sustained by ion cyclotron resonance heating (ICRH) and electron cyclotron heating (ECH), helium is observed to be highly retained in the wall (regarded as both the first wall and the divertor tiles). Almost all (about 96%) puffed helium particles (1.3 × 10{sup 22} He) are absorbed in the wall near the end of the discharge. Even though a dynamic retention is eliminated, 56% is still absorbed. The analysis is also applied to longer pulse discharges over 40 min by ICRH and ECH, indicating that the helium wall retention is dynamically changed in time. At the initial phase of the discharge, a mechanism for adsorbing helium other than dynamical retention is invoked.

  8. Initial yields of DNA double-strand breaks and DNA Fragmentation patterns depend on linear energy transfer in tobacco BY-2 protoplasts irradiated with helium, carbon and neon ions.

    Science.gov (United States)

    Yokota, Yuichiro; Yamada, Shinya; Hase, Yoshihiro; Shikazono, Naoya; Narumi, Issay; Tanaka, Atsushi; Inoue, Masayoshi

    2007-01-01

    The ability of ion beams to kill or mutate plant cells is known to depend on the linear energy transfer (LET) of the ions, although the mechanism of damage is poorly understood. In this study, DNA double-strand breaks (DSBs) were quantified by a DNA fragment-size analysis in tobacco protoplasts irradiated with high-LET ions. Tobacco BY-2 protoplasts, as a model of single plant cells, were irradiated with helium, carbon and neon ions having different LETs and with gamma rays. After irradiation, DNA fragments were separated into sizes between 1600 and 6.6 kbp by pulsed-field gel electrophoresis. Information on DNA fragmentation was obtained by staining the gels with SYBR Green I. Initial DSB yields were found to depend on LET, and the highest relative biological effectiveness (about 1.6) was obtained at 124 and 241 keV/microm carbon ions. High-LET carbon and neon ions induced short DNA fragments more efficiently than gamma rays. These results partially explain the large biological effects caused by high-LET ions in plants.

  9. Helium-3 and Helium-4 acceleration by high power laser pulses for hadron therapy

    CERN Document Server

    Bulanov, S S; Schroeder, C B; Leemans, W P; Bulanov, S V; Margarone, D; Korn, G; Haberer, T

    2015-01-01

    The laser driven acceleration of ions is considered a promising candidate for an ion source for hadron therapy of oncological diseases. Though proton and carbon ion sources are conventionally used for therapy, other light ions can also be utilized. Whereas carbon ions require 400 MeV per nucleon to reach the same penetration depth as 250 MeV protons, helium ions require only 250 MeV per nucleon, which is the lowest energy per nucleon among the light ions. This fact along with the larger biological damage to cancer cells achieved by helium ions, than that by protons, makes this species an interesting candidate for the laser driven ion source. Two mechanisms (Magnetic Vortex Acceleration and hole-boring Radiation Pressure Acceleration) of PW-class laser driven ion acceleration from liquid and gaseous helium targets are studied with the goal of producing 250 MeV per nucleon helium ion beams that meet the hadron therapy requirements. We show that He3 ions, having almost the same penetration depth as He4 with the ...

  10. Helium-3 and helium-4 acceleration by high power laser pulses for hadron therapy

    Directory of Open Access Journals (Sweden)

    S. S. Bulanov

    2015-06-01

    Full Text Available The laser driven acceleration of ions is considered a promising candidate for an ion source for hadron therapy of oncological diseases. Though proton and carbon ion sources are conventionally used for therapy, other light ions can also be utilized. Whereas carbon ions require 400 MeV per nucleon to reach the same penetration depth as 250 MeV protons, helium ions require only 250 MeV per nucleon, which is the lowest energy per nucleon among the light ions (heavier than protons. This fact along with the larger biological damage to cancer cells achieved by helium ions, than that by protons, makes this species an interesting candidate for the laser driven ion source. Two mechanisms (magnetic vortex acceleration and hole-boring radiation pressure acceleration of PW-class laser driven ion acceleration from liquid and gaseous helium targets are studied with the goal of producing 250 MeV per nucleon helium ion beams that meet the hadron therapy requirements. We show that He^{3} ions, having almost the same penetration depth as He^{4} with the same energy per nucleon, require less laser power to be accelerated to the required energy for the hadron therapy.

  11. Pulsed extraction of ionization from helium buffer gas

    OpenAIRE

    Morrissey, D. J.; Bollen, G.; Facina, M.; Schwarz, S.

    2008-01-01

    The migration of intense ionization created in helium buffer gas under the influence of applied electric fields is considered. First the chemical evolution of the ionization created by fast heavy-ion beams is described. Straight forward estimates of the lifetimes for charge exchange indicate a clear suppression of charge exchange during ion migration in low pressure helium. Then self-consistent calculations of the migration of the ions in the electric field of a gas-filled cell at the Nationa...

  12. In Beam Tests of Implanted Helium Targets

    CERN Document Server

    McDonald, J E; Ahmed, M W; Blackston, M A; Delbar, T; Gai, M; Kading, T J; Parpottas, Y; Perdue, B A; Prior, R M; Rubin, D A; Spraker, M C; Yeomans, J D; Weissman, L; Weller, H R; Delbar, Th.; Conn, LNS/U; Duke, TUNL/

    2006-01-01

    Targets consisting of 3,4He implanted into thin aluminum foils (approximately 100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation was achieved by a beam raster across a 12 mm diameter tantalum collimator at the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal direction. Helium implantation into the very thin (approximately 80-100 ug/cm^2) aluminum foils failed to produce useful targets (with only approximately 10% of the helium retained) due to an under estimation of the range by the code SRIM. The range of low energy helium in aluminum predicted by Northcliffe and Shilling and the NIST online tabulation are observed on the other hand to over estimate the range of low energy helium ions in aluminum. An attempt to increase the amount of helium by implanting a second deeper layer was also carried out, but it did not significantly increase the helium content beyond the blistering limit (ap...

  13. IFRS 8 OPERATING SEGMENTS: Eine Untersuchung der erstmaligen Anwendung in der Schweiz

    OpenAIRE

    Meyer, C.; Weiss, S. (Stefan)

    2010-01-01

    Seit dem 1. Januar 2009 sind kotierte IFRS-Anwender verpflichtet, eine Segmentberichterstattung nach IFRS 8 zu erstellen. Anhand einer Analyse der Geschäftsberichte 2009 der an der SIX Swiss Exchange kotierten Unternehmen soll ein Überblick über die erstmalige Anwendung von IFRS 8 "Operating Segments" in der Schweiz gewonnen werden.

  14. Nuclear polarizability of helium isotopes in atomic transitions

    OpenAIRE

    Pachucki, K.; Moro, A. M.

    2006-01-01

    We estimate the nuclear polarizability correction to atomic transition frequencies in various helium isotopes. This effect is non-negligible for high precision tests of quantum electrodynamics or accurate determination of the nuclear charge radius from spectroscopic measurements in helium atoms and ions. In particular, it amounts to $28(3)$ kHz for 1S-2S transition in 4He+.

  15. Elastic recoil cross section determination of deuterium by helium-4 ions at 30° with the energy range of 2.6–7.4 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Han, Zhibin; Hao, Wanli; Wang, Chunjie; Shi, Liqun, E-mail: lqshi@fudan.edu.cn

    2016-05-15

    The elastic recoil cross section for D({sup 4}He, D) {sup 4}He was determined at a recoil angle of 30° over an incident helium energy range from 2.6 to 7.4 MeV. A thin solid target Ta/TiD{sub x}/Si used for cross section measurement was prepared by direct current magnetron sputtering, and it was so stable to ion beam bombardment that nearly no deuterium loss (less than 0.2%) exists over the whole experiment. A relative determination method is adopted in this measurement. It can avoid the error from the beam dose and the solid angle of the detectors and it is also free to direct measurement of D content in the film. The total uncertainty in the cross section determination is less than 5%.

  16. Energetic ionized helium in the quiet time radiation belts - Theory and comparison with observation

    Science.gov (United States)

    Spjeldvik, W. N.; Fritz, T. A.

    1978-01-01

    Theoretical calculations of helium ion distributions in the inner magnetosphere are compared to observations made by ATS-6 and Explorer-45. Coupled transport equations for equatorially mirroring singly and doubly ionized helium ions in the steady state limit with an outer boundary of L = 7 are solved. Radial profiles and energy spectra are computed at all lower L values. Theoretical quiet time predictions are compared to satellite observations of energetic helium ions in the lower MeV range. It is found that the theory adequately represents the principal characteristics of the radiation belt helium ion population.

  17. Space and time resolved spectroscopy of laser-produced plasmas: A study of density-sensitive x-ray transitions in helium-like and neon-like ions

    Energy Technology Data Exchange (ETDEWEB)

    Young, Bruce Kai Fong

    1988-09-01

    The determination of level populations and detailed population mechanisms in dense plasmas has become an increasingly important problem in atomic physics. In this work, the density variation of line intensities and level populations in aluminum K-shell and molybdenum and silver L-shell emission spectra have been measured from high-powered, laser-produced plasmas. For each case, the density dependence of the observed line emission is due to the effect of high frequency electron-ion collisions on metastable levels. The density dependent line intensities vary greatly in laser-produced plasmas and can be used to extract detailed information concerning the population kinetics and level populations of the ions. The laser-plasmas had to be fully characterized in order to clearly compare the observed density dependence with atomic theory predictions. This has been achieved through the combined use of new diagnostic instruments and microdot targets which provided simultaneously space, time, and spectrally resolved data. The plasma temperatures were determined from the slope of the hydrogen-like recombination continuum. The time resolved electron density profiles were measured using multiple frame holographic interferometry. Thus, the density dependence of K-shell spectral lines could be clearly examined, independent of assumptions concerning the dynamics of the plasma. In aluminum, the electron density dependence of various helium-like line intensity ratios were measured. Standard collisional radiative equilibrium models fail to account for the observed density dependence measured for the ''He/sub ..cap alpha..//IC'' ratio. Instead, a quasi-steady state atomic model based on a purely recombining plasma is shown to accurately predict the measured density dependence. This same recombining plasma calculation successfully models the density dependence of the high-n ''He/sub ..gamma..//He/sub ..beta../'' and ''He/sub delta

  18. The helium question.

    Science.gov (United States)

    Cook, E

    1979-12-07

    Helium appears indispensable for certain energy-related uses that may be important 50 years from now, when helium-bearing natural gas, a much cheaper source than air, may be exhausted. Present demand, however, is lower than productive capacity, and much helium is being dissipated into the atmosphere as natural gas is burned for fuel. Controversy over the need for a government-directed helium-conservation program reflects fundamental differences in viewpoints on the economic future of industrial society, on the limits of substitution of labor and capital for a depleting resource, and on intergenerational equity and risk-bearing.

  19. Interatomic Coulombic decay in helium nanodroplets

    DEFF Research Database (Denmark)

    Shcherbinin, Mykola; Laforge, Aaron; Sharma, Vandana

    2017-01-01

    Interatomic Coulombic decay (ICD) is induced in helium nanodroplets by photoexciting the n=2 excited state of He+ using XUV synchrotron radiation. By recording multiple-coincidence electron and ion images we find that ICD occurs in various locations at the droplet surface, inside the surface region...

  20. Helium behaviour in implanted boron carbide

    Directory of Open Access Journals (Sweden)

    Motte Vianney

    2015-01-01

    Full Text Available When boron carbide is used as a neutron absorber in nuclear power plants, large quantities of helium are produced. To simulate the gas behaviour, helium implantations were carried out in boron carbide. The samples were then annealed up to 1500 °C in order to observe the influence of temperature and duration of annealing. The determination of the helium diffusion coefficient was carried out using the 3He(d,p4He nuclear reaction (NRA method. From the evolution of the width of implanted 3He helium profiles (fluence 1 × 1015/cm2, 3 MeV corresponding to a maximum helium concentration of about 1020/cm3 as a function of annealing temperatures, an Arrhenius diagram was plotted and an apparent diffusion coefficient was deduced (Ea = 0.52 ± 0.11 eV/atom. The dynamic of helium clusters was observed by transmission electron microscopy (TEM of samples implanted with 1.5 × 1016/cm2, 2.8 to 3 MeV 4He ions, leading to an implanted slab about 1 μm wide with a maximum helium concentration of about 1021/cm3. After annealing at 900 °C and 1100 °C, small (5–20 nm flat oriented bubbles appeared in the grain, then at the grain boundaries. At 1500 °C, due to long-range diffusion, intra-granular bubbles were no longer observed; helium segregates at the grain boundaries, either as bubbles or inducing grain boundaries opening.

  1. Helium the disappearing element

    CERN Document Server

    Sears, Wheeler M

    2015-01-01

    The subject of the book is helium, the element, and its use in myriad applications including MRI machines, particle accelerators, space telescopes, and of course balloons and blimps. It was at the birth of our Universe, or the Big Bang, where the majority of cosmic helium was created; and stellar helium production continues. Although helium is the second most abundant element in the Universe, it is actually quite rare here on Earth and only exists because of radioactive elements deep within the Earth. This book includes a detailed history of the discovery of helium, of the commercial industry built around it, how the helium we actually encounter is produced within the Earth, and the state of the helium industry today. The gas that most people associate with birthday party balloons is running out. “Who cares?” you might ask. Well, without helium, MRI machines could not function, rockets could not go into space, particle accelerators such as those used by CERN could not operate, fiber optic cables would not...

  2. Electronic Transport in Helium Beam Modified Graphene and Ballistic Josephson Junctions

    NARCIS (Netherlands)

    Nanda, G.

    2017-01-01

    This thesis describes the capabilities of the helium ion microscope (HIM) and that of graphene to explore fundamental physics and novel applications. While graphene offers superior electronic properties, the helium ion microscope allows us to combine imaging and modification of materials at the

  3. The core helium flash

    Science.gov (United States)

    Cole, P. W.; Deupree, R. G.

    1980-12-01

    The role of convection in the core helium flash is simulated by two-dimensional eddies interacting with the thermonuclear runaway. These eddies are followed by the explicit solution of the two-dimensional conservation laws with a two-dimensional finite difference hydrodynamics code. Thus, no phenomenological theory of convection such as the local mixing length theory is required. The core helium flash is violent, producing a deflagration wave. This differs from the detonation wave (and subsequent disruption of the entire star) produced in previous spherically symmetric violent core helium flashes as the second dimension provides a degree of relief which allows the expansion wave to decouple itself from the burning front. The results predict that a considerable amount of helium in the core will be burned before the horizontal branch is reached and that some envelope mass loss is likely.

  4. The Descending Helium Balloon

    Science.gov (United States)

    Helseth, Lars Egil

    2014-01-01

    I describe a simple and fascinating experiment wherein helium leaks out of a rubber balloon, thereby causing it to descend. An estimate of the volumetric leakage rate is made by measuring its rate of descent.

  5. Effect of weld thermal cycle on helium bubble formation in stainless steel

    Science.gov (United States)

    Kano, F.; Nakahigashi, S.; Nakamura, H.; Uesugi, N.; Mitamura, T.; Terasawa, M.; Irie, H.; Fukuya, K.

    1998-10-01

    Helium bubble structure was examined on a helium-implanted stainless steel after applying two kinds of heat input. Helium ions were implanted on Type 304 stainless steel at 573 K from 2 to 200 appm to a peak depth of 0.5 μm from the surface. After that, weld thermal history was applied by an electron beam. The cooling rates were selected to be 370 and 680 K/s from 1023 to 773 K. TEM observation revealed that nucleation and growth of helium bubbles were strongly dependent on the cooling rate after welding and the helium concentration.

  6. Chromosomal rearrangements in interspecific hybrids between Nicotiana gossei Domin and N. tabacum L., obtained by crossing with pollen exposed to helium ion beams or gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, S. E-mail: kitamura@taka.jaeri.go.jp; Inoue, M.; Ohmido, N.; Fukui, K.; Tanaka, A

    2003-05-01

    It is very difficult to obtain interspecific hybrids between Nicotiana tabacum L. (2n=48) and N. gossei Domin (2n=36), because of strong cross incompatibility. We had already obtained interspecific hybrids between these two species, crossing N. gossei flower with N. tabacum pollen exposed to He ions or gamma-rays. Here, we analyze chromosome constitution of these hybrids by genomic in situ hybridization. In root tip cells of the two hybrids obtained with He ion exposure, most mitotic cells contained 18 chromosomes of N. gossei and 24 chromosomes of N. tabacum. However, in some cells, translocations and insertions between parental genomes were observed. On the other hand, in a hybrid obtained by gamma-ray irradiation, intergenomic rearrangements were not observed, although mitotic cells showed 19 hybridization signals with N. gossei DNA in 41 chromosomes. Such chromosomal changes in structure or constitution may be related to overcoming cross incompatibility between these two species.

  7. Chromosomal rearrangements in interspecific hybrids between Nicotiana gossei Domin and N. tabacum L., obtained by crossing with pollen exposed to helium ion beams or gamma-rays

    Science.gov (United States)

    Kitamura, S.; Inoue, M.; Ohmido, N.; Fukui, K.; Tanaka, A.

    2003-05-01

    It is very difficult to obtain interspecific hybrids between Nicotiana tabacum L. (2 n=48) and N. gossei Domin (2 n=36), because of strong cross incompatibility. We had already obtained interspecific hybrids between these two species, crossing N. gossei flower with N. tabacum pollen exposed to He ions or gamma-rays. Here, we analyze chromosome constitution of these hybrids by genomic in situ hybridization. In root tip cells of the two hybrids obtained with He ion exposure, most mitotic cells contained 18 chromosomes of N. gossei and 24 chromosomes of N. tabacum. However, in some cells, translocations and insertions between parental genomes were observed. On the other hand, in a hybrid obtained by gamma-ray irradiation, intergenomic rearrangements were not observed, although mitotic cells showed 19 hybridization signals with N. gossei DNA in 41 chromosomes. Such chromosomal changes in structure or constitution may be related to overcoming cross incompatibility between these two species.

  8. General mechanism for helium blistering involving displaced atom transport

    Energy Technology Data Exchange (ETDEWEB)

    McDonell, W.R.

    1979-01-01

    A mechanism developed to account for formation of vertically elongated blisters in high displacement environments produced by /sup 252/Cf alpha particles and fission fragments has been extended to formation of done-shaped blisters in the low displacement environments produced by simple helium ion beams. In this mechanism, transport of displaced atoms to relieve compressive stresses in the helium-implanted layer allows interconnections of small, subsurface bubbles to form the blister cavity. The same transport may cause thickening of the blister caps at low implantation energies. The transition from dome-shaped to vertically elongated blistering occurs between the 300 and 3000 displacements per helium atom produced by simple helium ions and /sup 252/Cf radiations respectively.

  9. Projektierung einer automatischen Montageanlage für Textilspindeln unter Anwendung der DIN EN ISO 13849

    OpenAIRE

    Barthel, Sven; Koch, Thomas; Richter, Mark; Blau, Peter

    2011-01-01

    Die Festlegung der Sicherheitsmaßnahmen unter technischen und ökonomischen Randbedingungen stellt in Unternehmen eine Herausforderung dar. Die "Maschinenrichtlinie 2006/42/EWG" [4] in Verbindung mit den weiterführenden Normen, wie beispielsweise die "DIN ISO 13849-1" [2], stellt dem Anwender hierfür eine geeignete Systematik zur Verfügung. Nachfolgend wird am Beispiel einer automatischen Montageanlage für Textilspindeln die Anwendung der Richtlinie aufgezeigt und für die Sicherheitsfunktion "...

  10. Formation of interstitial atoms in surface layers of helium-implanted tungsten

    Science.gov (United States)

    Dudka, O. V.; Ksenofontov, V. A.; Masilov, A. A.; Sadanov, E. V.

    2013-11-01

    Using a method of field ion microscopy, the atomic structure of surface and near-surface layers of a perfect dislocation-free tungsten irradiated by helium ions with energies below the threshold of displacement was studied. We have found the output of tungsten atoms from the bulk as a result of their displacement from regular lattice positions occupied by implanted helium atoms and the formation of interstitial tungsten atoms. It is shown that high concentrations of helium and the presence of image forces have a considerable effect on the development of these processes. Depleted zones consisting of helium-vacancy complexes are revealed within the irradiated near-surface layer.

  11. Cavitation in flowing superfluid helium

    Science.gov (United States)

    Daney, D. E.

    1988-01-01

    Flowing superfluid helium cavitates much more readily than normal liquid helium, and there is a marked difference in the cavitation behavior of the two fluids as the lambda point is traversed. Examples of cavitation in a turbine meter and centrifugal pump are given, together with measurements of the cavitation strength of flowing superfluid helium. The unusual cavitation behavior of superfluid helium is attributed to its immense thermal conductivity .

  12. Broken symmetry makes helium

    CERN Multimedia

    Gray, P L

    2003-01-01

    "The subatomic pion particle breaks the charge symmetry rule that governs both fusion and decay. In experiments performed at the Indiana University Cyclotron Laboratory, physicists forced heavy hydrogen (1 proton + 1 neutron) to fuse into helium in a controlled, measurable environment" (1 paragraph).

  13. Kinetic approach to the helium transport in a divertor plasma along the magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Krasheninnikov, S.I.; Soboleva, T.K. (I.V. Kurchatov Inst. of Atomic Energy, Ploshchad akademika Kurchatova, 123281 Moscos (SU)); Gac, K. (Instytut Fizyki Plazmy i Laserowej Mikrosyntezy, Warsaw (Poland))

    1990-11-01

    This paper considers impurity (helium) ion transport kinetics in a tokamak divertor along magnetic field lines, both analytically and numerically, for the case when the ratio of collisional mean-free-path to the characteristic length of plasma parameter variation is not too small. To obtain the numerical solution of the kinetics equation, the stochastic modeling method is used. For International Thermonuclear Experimental Reactor (ITER) divertor plasma conditions, the influence of thermal force on helium ions is expected to be decreased considerably. As a result, the helium ion flux toward the divertor plates may be significantly enhanced compared to that predicted by the hydrodynamics approach.

  14. Applications of Groundwater Helium

    Science.gov (United States)

    Kulongoski, Justin T.; Hilton, David R.

    2011-01-01

    Helium abundance and isotope variations have widespread application in groundwater-related studies. This stems from the inert nature of this noble gas and the fact that its two isotopes ? helium-3 and helium-4 ? have distinct origins and vary widely in different terrestrial reservoirs. These attributes allow He concentrations and 3He/4He isotope ratios to be used to recognize and quantify the influence of a number of potential contributors to the total He budget of a groundwater sample. These are atmospheric components, such as air-equilibrated and air-entrained He, as well as terrigenic components, including in situ (aquifer) He, deep crustal and/or mantle He and tritiogenic 3He. Each of these components can be exploited to reveal information on a number of topics, from groundwater chronology, through degassing of the Earth?s crust to the role of faults in the transfer of mantle-derived volatiles to the surface. In this review, we present a guide to how groundwater He is collected from aquifer systems and quantitatively measured in the laboratory. We then illustrate the approach of resolving the measured He characteristics into its component structures using assumptions of endmember compositions. This is followed by a discussion of the application of groundwater He to the types of topics mentioned above using case studies from aquifers in California and Australia. Finally, we present possible future research directions involving dissolved He in groundwater.

  15. Evolution Law of Helium Bubbles in Hastelloy N Alloy on Post-Irradiation Annealing Conditions

    Directory of Open Access Journals (Sweden)

    Jie Gao

    2016-10-01

    Full Text Available This work reports on the evolution law of helium bubbles in Hastelloy N alloy on post-irradiation annealing conditions. After helium ion irradiation at room temperature and subsequent annealing at 600 °C (1 h, the transmission electron microscopy (TEM micrograph indicates the presence of helium bubbles with size of 2 nm in the depth range of 0–300 nm. As for the sample further annealed at 850 °C (5 h, on one hand, a “Denuded Zone” (0–38 nm with rare helium bubbles forms due to the decreased helium concentration. On the other hand, the “Ripening Zone” (38–108 nm and “Coalescence Zone” (108–350 nm with huge differences in size and separation of helium bubbles, caused by different coarsening rates, are observed. The mechanisms of “Ostwald ripening” and “migration and coalescence”, experimentally proved in this work, may explain these observations.

  16. 48 CFR 52.208-8 - Required Sources for Helium and Helium Usage Data.

    Science.gov (United States)

    2010-10-01

    ... Helium and Helium Usage Data. 52.208-8 Section 52.208-8 Federal Acquisition Regulations System FEDERAL... Provisions and Clauses 52.208-8 Required Sources for Helium and Helium Usage Data. As prescribed in 8.505, insert the following clause: Required Sources for Helium and Helium Usage Data (APR 2002) (a) Definitions...

  17. Atomically resolved phase transition of fullerene cations solvated in helium droplets

    Science.gov (United States)

    Kuhn, M.; Renzler, M.; Postler, J.; Ralser, S.; Spieler, S.; Simpson, M.; Linnartz, H.; Tielens, A. G. G. M.; Cami, J.; Mauracher, A.; Wang, Y.; Alcamí, M.; Martín, F.; Beyer, M. K.; Wester, R.; Lindinger, A.; Scheier, P.

    2016-11-01

    Helium has a unique phase diagram and below 25 bar it does not form a solid even at the lowest temperatures. Electrostriction leads to the formation of a solid layer of helium around charged impurities at much lower pressures in liquid and superfluid helium. These so-called `Atkins snowballs' have been investigated for several simple ions. Here we form HenC60+ complexes with n exceeding 100 via electron ionization of helium nanodroplets doped with C60. Photofragmentation of these complexes is measured by merging a tunable narrow-bandwidth laser beam with the ions. A switch from red- to blueshift of the absorption frequency of HenC60+ on addition of He atoms at n=32 is associated with a phase transition in the attached helium layer from solid to partly liquid (melting of the Atkins snowball). Elaborate molecular dynamics simulations using a realistic force field and including quantum effects support this interpretation.

  18. Scaling of cross-sections for asymmetric (e,3e) process on helium ...

    Indian Academy of Sciences (India)

    Abstract. An approximate simple scaling law is obtained for asymmetric (e, 3e) process on helium-like ions for double ionization by fast electrons. It is based on the equation. (Z 3/π) exp[−Z (r1 + r2)], Z = Z − (5/16) for ground state wave function of helium- like ions and Z 2 scaling of energies. The scaling law is found to work ...

  19. Haben soziale Merkmale von Patientinnen und Patienten einen Einfluss auf die Anwendung von diagnostischen und therapeutischen Herzkathetern?

    OpenAIRE

    Ryl, Livia

    2007-01-01

    In der vorliegenden Dissertation wird untersucht, inwiefern sich soziale Ungleichheit in der akutkardiologischen Versorgung bezogen auf die Anwendung diagnostischer und therapeutischer Herzkatheter auswirkt. Die Brisanz des Themas für den Public-Health-Bereich ergibt sich aus der großen gesundheitspolitischen und gesellschaftlichen Bedeutung der Herzkrankheiten. Diese wird durch die Prävalenz, die erhöhte Mortalität und Folgeerkrankungen erzeugt. Betroffene erleben eine besondere Belastung, d...

  20. High Efficiency Regenerative Helium Compressor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Helium plays several critical rolls in spacecraft propulsion. High pressure helium is commonly used to pressurize propellant fuel tanks. Helium cryocoolers can be...

  1. Cavitation in liquid helium

    Energy Technology Data Exchange (ETDEWEB)

    Finch, R. D.; Kagiwada, R.; Barmatz, M.; Rudnick, I.

    1963-11-15

    Ultrasonic cavitation was induced in liquid helium over the temperature range 1.2 to 2.3 deg K, using a pair of identical transducers. The transducers were calibrated using a reciprocity technique and the cavitation threshold was determined at 90 kc/s. It was found that this threshold has a sharp peak at the lambda point, but is, at all temperatures quite low, with an approximate range of 0.001 to 0.01 atm. The significance of the results is discussed. (auth)

  2. Tritium decay helium-3 effects in tungsten

    Directory of Open Access Journals (Sweden)

    M. Shimada

    2017-08-01

    Full Text Available Tritium (T implanted by plasmas diffuses into bulk material, especially rapidly at elevated temperatures, and becomes trapped in neutron radiation-induced defects in materials that act as trapping sites for the tritium. The trapped tritium atoms will decay to produce helium-3 (3He atoms at a half-life of 12.3 years. 3He has a large cross section for absorbing thermal neutrons, which after absorbing a neutron produces hydrogen (H and tritium ions with a combined kinetic energy of 0.76 MeV through the 3He(n,HT nuclear reaction. The purpose of this paper is to quantify the 3He produced in tungsten by tritium decay compared to the neutron-induced helium-4 (4He produced in tungsten. This is important given the fact that helium in materials not only creates microstructural damage in the bulk of the material but alters surface morphology of the material effecting plasma-surface interaction process (e.g. material evolution, erosion and tritium behavior of plasma-facing component materials. Effects of tritium decay 3He in tungsten are investigated here with a simple model that predicts quantity of 3He produced in a fusion DEMO FW based on a neutron energy spectrum found in literature. This study reveals that: (1 helium-3 concentration was equilibrated to ∼6% of initial/trapped tritium concentration, (2 tritium concentration remained approximately constant (94% of initial tritium concentration, and (3 displacement damage from 3He(n,HT nuclear reaction became >1 dpa/year in DEMO FW.

  3. Application of C-arm computed tomography in cardiology; Kardiale Anwendung der C-Arm-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, J. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Innenstadt, Abteilung fuer Kardiologie, Medizinische Poliklinik, Muenchen (Germany); Rohkohl, C. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Lehrstuhl fuer Mustererkennung, Department Informatik, Erlangen (Germany); Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Lauritsch, G. [Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Rittger, H. [Krankenhaus Coburg, Abteilung fuer Kardiologie, Coburg (Germany); Meissner, O. [Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2009-09-15

    C-arm computed tomography is currently being introduced into cardiac imaging and offers the potential for three-dimensional imaging of the cardiac anatomy within the interventional environment. This detailed view is necessary to support complex interventional strategies, such as transcutaneous valve replacement, interventional therapy of atrial fibrillation, implantation of biventricular pacemakers and assessment of myocardial perfusion. Currently, the major limitation of this technology is its insufficient temporal resolution which limits the visualization of fast moving parts of the heart. (orig.) [German] Durch die Entwicklung der C-Arm-Computertomographie- (CACT-)Angiographie ist es erstmals moeglich, waehrend einer Herzkatheteruntersuchung eine detaillierte dreidimensionale Darstellung der kardialen Anatomie zu erhalten. Derartige zusaetzliche Informationen koennten die Durchfuehrung der immer komplexer werdenden Strategien der interventionellen Kardiologie wirkungsvoll unterstuetzen. Hierzu zaehlen u. a. der transkutane Klappenersatz, die interventionelle Behandlung von Vorhofflimmern, die Implantation biventrikulaerer Schrittmacher sowie die Beurteilung der Myokardperfusion. Die derzeit groesste Limitation dieser Methode ist die relativ geringe zeitliche Aufloesung, die aufgrund der Bewegung des Herzens die Anwendung dieser Technologie einschraenkt. (orig.)

  4. Electronic properties of physisorbed helium

    Energy Technology Data Exchange (ETDEWEB)

    Kossler, Sarah

    2011-09-22

    This thesis deals with electronic excitations of helium physisorbed on metal substrates. It is studied to what extent the electronic properties change compared to the gas phase due to the increased helium density and the proximity of the metal. Furthermore, the influence of different substrate materials is investigated systematically. To this end, up to two helium layers were adsorbed onto Ru (001), Pt (111), Cu (111), and Ag (111) surfaces in a custom-made cryostat. These samples were studied spectroscopically using synchrotron radiation and a time-of-flight detector. The experimental results were then analyzed in comparison with extensive theoretical model calculations.

  5. Trapping fermionic and bosonic helium atoms

    NARCIS (Netherlands)

    Stas, R.J.W.

    2005-01-01

    This thesis presents experimental and theoretical work performed at the Laser Centre of the Vrije Universiteit in Amsterdam to study laser-cooled metastable triplet helium atoms. Samples containing about 3x10^8 helium atoms-either fermionic helium-3 atoms, bosonic helium-4 atoms or mixtures

  6. Quantum interference spectroscopy of rubidium-helium exciplexes formed on helium nanodroplets.

    Science.gov (United States)

    Mudrich, M; Stienkemeier, F; Droppelmann, G; Claas, P; Schulz, C P

    2008-01-18

    Femtosecond multiphoton pump-probe photoionization is applied to helium nanodroplets doped with rubidium (Rb). The yield of Rb+ ions features pronounced quantum interference (QI) fringes demonstrating the coherence of a superposition of electronic states on a time scale of tens of picoseconds. Furthermore, we observe QI in the yield of formed RbHe exciplex molecules. The quantum interferogram allows us to determine the vibrational structure of these unstable molecules. From a sliced Fourier analysis one cannot only extract the population dynamics of vibrational states but also follow their energetic evolution during the RbHe formation.

  7. Comparison of blistering of W bulk and film deposited by magnetron sputtering under helium irradiation

    Directory of Open Access Journals (Sweden)

    Jiangang Yu

    2017-08-01

    Full Text Available In this work, the W bulk prepared by powder sintering and W film deposited by magnetron sputtering were simultaneously exposed to the helium ions with the energy of 60keV and fluence of 1.0 × 1022 m−2 at room temperature. The surface modifications induced by the helium irradiation were studied by scanning electron microscopy. After helium ion irradiation, numerous blisters were observed on the surface of both samples, some of which burst in various degrees. The formation of blisters is attributed to the high gas pressure in the helium bubbles. In addition, the different structures between W bulk and W film lead to the differences in density and size of blisters.

  8. Ansätze zur Ordnungsreduktion von nichtlinearen Oszillatormodellen zur Anwendung im Schaltungsentwurf

    Science.gov (United States)

    Reit, M.; Bremer, J.-K.; Mathis, W.; Stoop, R.

    2010-10-01

    Im Rahmen dieser Arbeit wird ein Konzept zur Ordnungsreduktion von höherdimensionalen nichtlinearen Oszillatormodellen vorgestellt. Hierbei werden zwei wesentliche Ziele verfolgt. Zum einen wird eine höherdimensionale Modellierung der Oszillatorschaltung verwendet. Hierdurch lassen sich die Einflüsse parasitärer Effekte sowie struktureller Erweiterungen auf das dynamische Verhalten des Systems berücksichtigen. Zum anderen wird durch eine anschließende Ordnungsreduktion über die Methode der Zentrumsmannigfaltigkeit eine zweidimensionale Systembeschreibung erzeugt, deren wesentliche Dynamik derjenigen des höherdimensionalen Systems entspricht. Durch diese, in der Ordnung reduzierte, nichtlineare und parameterabhängige Systembeschreibung wird die Anwendbarkeit nichtlinearer Analysemethoden ermöglicht bzw. vereinfacht. Mit der Anwendung der Andronov-Hopf-Bifurkationsanalyse auf das reduzierte System lässt sich eine Stabilitätsuntersuchung durchführen sowie die Amplitude und Frequenz aller Zustandsgrößen approximieren. Das vorgestellte Konzept wird anhand des Beispielsystems eines LC-Tank-VCOs durchgeführt. In this paper, an order reduction technique for higher-dimensional nonlinear oscillator models, based on a center manifold approach, is presented. By modeling the oscillator circuit in the higher-dimensional state space, influences of parasitic elements and of structural extensions of the oscillator architecture on the dynamical system behavior can be examined. Using the proposed order reduction technique, a generalized second order model will be derived, which includes selected design parameters of the higher order model. By using an Andronov-Hopf bifurcation analysis, the reduced system can be studied with respect to stability as well as the amplitude and frequency of the individual state variables. The concept is applied to the design of LC-tank VCOs.

  9. ERDA, RBS, TEM and SEM characterization of microstructural evolution in helium-implanted Hastelloy N alloy

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Jie [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); School of Physical Sciences, University of Chinese Academy of Sciences, Beijing 100049 (China); Bao, Liangman [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Huang, Hefei, E-mail: huanghefei@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li, Yan, E-mail: liyan@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Lei, Qiantao [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Deng, Qi [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Liu, Zhe; Yang, Guo [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); School of Physical Sciences, University of Chinese Academy of Sciences, Beijing 100049 (China); Shi, Liqun [Institute of Modern Physics, Fudan University, Shanghai 200433 (China)

    2017-05-15

    Hastelloy N alloy was implanted with 30 keV, 5 × 10{sup 16} ions/cm{sup 2} helium ions at room temperature, and subsequent annealed at 600 °C for 1 h and further annealed at 850 °C for 5 h in vacuum. Using elastic recoil detection analysis (ERDA) and transmission electron microscopy (TEM), the depth profiles of helium concentration and helium bubbles in helium-implanted Hastelloy N alloy were investigated, respectively. The diffusion of helium and molybdenum elements to surface occurred during the vacuum annealing at 850 °C (5 h). It was also observed that bubbles in molybdenum-enriched region were much larger in size than those in deeper region. In addition, it is worth noting that plenty of nano-holes can be observed on the surface of helium-implanted sample after high temperature annealing by scanning electron microscope (SEM). This observation provides the evidence for the occurrence of helium release, which can be also inferred from the results of ERDA and TEM analysis.

  10. Effect of kinetic energy on the doping efficiency of cesium cations into superfluid helium droplets.

    Science.gov (United States)

    Chen, Lei; Zhang, Jie; Freund, William M; Kong, Wei

    2015-07-28

    We present an experimental investigation of the effect of kinetic energy on the ion doping efficiency of superfluid helium droplets using cesium cations from a thermionic emission source. The kinetic energy of Cs(+) is controlled by the bias voltage of a collection grid collinearly arranged with the droplet beam. Efficient doping from ions with kinetic energies from 20 eV up to 480 V has been observed in different sized helium droplets. The relative ion doping efficiency is determined by both the kinetic energy of the ions and the average size of the droplet beam. At a fixed source temperature, the number of doped droplets increases with increasing grid voltage, while the relative ion doping efficiency decreases. This result implies that not all ions are captured upon encountering with a sufficiently large droplet, a deviation from the near unity doping efficiency for closed shell neutral molecules. We propose that this drop in ion doping efficiency with kinetic energy is related to the limited deceleration rate inside a helium droplet. When the source temperature changes from 14 K to 17 K, the relative ion doping efficiency decreases rapidly, perhaps due to the lack of viable sized droplets. The size distribution of the Cs(+)-doped droplet beam can be measured by deflection and by energy filtering. The observed doped droplet size is about 5 × 10(6) helium atoms when the source temperature is between 14 K and 17 K.

  11. Effects of ionizing radiation on the light sensing elements of the retina. [Structural and physiological effects of carbon, helium, and neon ions on rods and cones of salamanders and mice

    Energy Technology Data Exchange (ETDEWEB)

    Malachowski, M.J.

    1978-07-01

    This investigation was undertaken to quantitate possible morphological and physiological effects of particles of high linear energy transfer on the retina, in comparison with x-ray effects. The particles used were accelerated atomic nuclei of helium, carbon, and neon at kinetic energies of several hundred MeV/nucleon. For morphological studies, scanning and transmission electron microscopy and light microscopy were used. Physiological studies consisted of autoradiographic data of the rate of incorporation of labeled protein in the structures (opsin) of the outer segment of visual cells. Structural changes were found in the nuclei, as well as the inner and outer segments of visual cells, rods and cones. At a low dose of 10 rad, x rays and helium had no statistically significant morphological effects, but carbon and neon beams did cause significant degeneration of individual cells, pointing to the existence of a linear dose--effect relationship. At high doses of several hundred rads, a Pathologic Index determined the relative biological effectiveness of neon against alpha particles to have a value of greater than 6. The severity of effects per particle increased with atomic number. Labeling studies demonstrated a decreased rate of incorporation of labeled proteins in the structural organization of the outer segments of visual rods. The rate of self-renewal of visual rod discs was punctuated by irradiation and the structures themselves were depleted of amino acids. A model of rod discs (metabolic and catabolic) was postulated for correlated early and late effects to high and low doses.

  12. Charge transfer dissociation (CTD) mass spectrometry of peptide cations using kiloelectronvolt helium cations.

    Science.gov (United States)

    Hoffmann, William D; Jackson, Glen P

    2014-11-01

    A kiloelectronvolt beam of helium ions is used to ionize and fragment precursor peptide ions starting in the 1+ charge state. The electron affinity of helium cations (24.6 eV) exceeds the ionization potential of protonated peptides and can therefore be used to abstract an electron from--or charge exchange with--the isolated precursor ions. Kiloelectronvolt energies are used, (1) to overcome the Coulombic repulsion barrier between the cationic reactants, (2) to overcome ion-defocussing effects in the ion trap, and (3) to provide additional activation energy. Charge transfer dissociation (CTD) of the [M+H](+) precursor of Substance P gives product ions such as [M+H](2+•) and a dominant series of a ions in both the 1+ and 2+ charge states. These observations, along with the less-abundant a + 1 ions, are consistent with ultraviolet photodissociation (UVPD) results of others and indicate that C-C(α) cleavages are possible through charge exchange with helium ions. Although the efficiencies and timescale of CTD are not yet suitable for on-line chromatography, this new approach to ion activation provides an additional potential tool for the interrogation of gas phase ions.

  13. Photoionization of helium dimers; Photoionisation von Heliumdimeren

    Energy Technology Data Exchange (ETDEWEB)

    Havermeier, Tilo

    2010-06-09

    The helium dimer is one of the most weakly bound systems in the universe. This makes it an interesting quantum mechanical object for investigation. These Van der Waals Clusters can be produced in an expansion of a cryogenic gas jet through a small nozzle into vacuum. In the present experiment we examine the interaction of He dimers with synchrotron radiation at an energy range from 64 to 78 eV. We observed different pathways leading to single ionization of both He atoms of the dimer compound. This two close standing ions begin now to dissociate in cause of their coulomb potential. All charged fragments were detected in coincidence with a COLTRIMS system. Especially Interatomic Coulombic Decay (ICD) and the two step process (TS1) were clearly identified. Furthermore a distribution of the internuclear distance was obtained from the measured Kinetic Energy Release (KER). (orig.)

  14. Formation of Au and tetrapyridyl porphyrin complexes in superfluid helium.

    Science.gov (United States)

    Feng, Cheng; Latimer, Elspeth; Spence, Daniel; Al Hindawi, Aula M A A; Bullen, Shem; Boatwright, Adrian; Ellis, Andrew M; Yang, Shengfu

    2015-07-14

    Binary clusters containing a large organic molecule and metal atoms have been formed by the co-addition of 5,10,15,20-tetra(4-pyridyl)porphyrin (H2TPyP) molecules and gold atoms to superfluid helium nanodroplets, and the resulting complexes were then investigated by electron impact mass spectrometry. In addition to the parent ion H2TPyP yields fragments mainly from pyrrole, pyridine and methylpyridine ions because of the stability of their ring structures. When Au is co-added to the droplets the mass spectra are dominated by H2TPyP fragment ions with one or more Au atoms attached. We also show that by switching the order in which Au and H2TPyP are added to the helium droplets, different types of H2TPyP-Au complexes are clearly evident from the mass spectra. This study suggests a new route for the control over the growth of metal-organic compounds inside superfluid helium nanodroplets.

  15. Helium irradiation induced hardening in MNHS steels

    Science.gov (United States)

    Cui, Minghuan; Wang, Ji; Wang, Zhiguang; Shen, Tielong; Wei, Kongfang; Yao, Cunfeng; Sun, Jianrong; Gao, Ning; Zhu, Yabin; Pang, Lilong; Wang, Dong; Zhu, Huiping; Han, Yi; Fang, Xuesong

    2017-09-01

    A recently developed reduced activation martensitic MNHS steel was irradiated with 200 keV helium (He) ions to a fluence of 1.0 × 1020 ions/m2 at 300 °C and 1.0 × 1021 ions/m2 at 300 °C and 450 °C. After irradiation, transmission electron microscopy (TEM) and nano-indentation measurements were used to investigate the hardness change and defects induced by He irradiation. Two kinds of defects including He bubbles and dislocation loops are observed by TEM. Irradiation induces hardening of MNHS steels and peak hardness values occur in all irradiated samples. Hardness increments induced by He bubbles and dislocation loops are predicted and fitted with the experimental peak hardness increment, based on the dispersed barrier-hardening (DBH) model and the size and number density of the two defects. A good agreement is got between the predicted and experimental hardness increment and the obstacle strength factor of He bubbles is a little stronger than the obstacle strength of dislocation loops. Other possible contributions to irradiation induced hardening are also discussed.

  16. Pierre Gorce working on a helium pump.

    CERN Multimedia

    1975-01-01

    This type of pump was designed by Mario Morpurgo, to circulate liquid helium in superconducting magnets wound with hollow conductors. M. Morpurgo, Design and construction of a pump for liquid helium, CRYIOGENICS, February 1977, p. 91

  17. Peculiarities of helium porosity formation in the surface layer of the structural materials used for the first wall of fusion reactor

    Science.gov (United States)

    Chernov, I. I.; Stal'tsov, M. S.; Kalin, B. A.; Bogachev, I. A.; Guseva, L. Yu.

    2016-03-01

    Transmission electron microscopy is used to study the formation of helium porosity in the nearsurface layer of ferritic-martensitic steels and vanadium irradiated by 40-keV He+ ions at a temperature of 923 K up to fluence of 5 × 1020 He+/m2 and, then, by 7.5-MeV Ni2+ ions at 923 K up to dose of 100 dpa. Large gas bubbles are found to form in the zone with the maximum concentration of radiation vacancies during He+ ion irradiation. Moreover, small bubbles form in some grains at the depths that are larger than the He+ ion range in the irradiated material. Sequential irradiation by He+ and Ni2+ ions leads to the nucleation of helium bubbles at still larger depths due to helium atom transport via recoil and/or ion mixing. The precipitation hardening of the steels by Y2O3 oxide nanoparticles is found to suppress helium swelling substantially.

  18. The integrity concept and its implementation; Das Integritaetskonzept und seine praktische Anwendung

    Energy Technology Data Exchange (ETDEWEB)

    Roos, E.; Herter, K.H.; Schuler, X. [Stuttgart Univ. (Germany). MPA; Koenig, G. [EnBW Kernkraft GmbH, Neckarwestheim (Germany)

    2008-07-01

    , dass fuer die Gewaehrleistung von Bruchausschluss die Beherrschung der Ursachen von im Betrieb moeglichen Schaedigungsmechanismen von entscheidender Bedeutung ist. Im Gegensatz dazu stellt das ''Integritaetskonzept'' als Umsetzung des Basissicherheitskonzepts unter Beruecksichtigung der jeweiligen anlagenspezifischen Voraussetzungen ein geschlossenes Gesamtkonzept dar, das der Notwendigkeit einer mehrstufigen Absicherung und ''laufender'' Aktualisierung Rechnung traegt. Das Integritaetskonzept ist Bestandteil des Alterungsmanagements fuer mechanische Komponenten und Systeme. Am Beispiel der Speisewasserleitung innerhalb Containment der Anlage GKN 1 wird dessen praktische Anwendung zum Nachweis der Integritaet aufgezeigt. (orig.)

  19. 21 CFR 184.1355 - Helium.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Helium. 184.1355 Section 184.1355 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN... Substances Affirmed as GRAS § 184.1355 Helium. (a) Helium (empirical formula He, CAS Reg. No. 7440-59-7) is a...

  20. 21 CFR 582.1355 - Helium.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Helium. 582.1355 Section 582.1355 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS... Helium. (a) Product. Helium. (b) Conditions of use. This substance is generally recognized as safe when...

  1. 30 CFR 256.11 - Helium.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Helium. 256.11 Section 256.11 Mineral Resources... Helium. (a) Each lease issued or continued under these regulations shall be subject to a reservation by the United States, under section 12(f) of the Act, of the ownership of and the right to extract helium...

  2. Pharmakokinetik von transdermalem Testosterongel bei Männern mit Hypogonadismus: Anwendung des Gels an einer Stelle im Vergleich zu vier Stellen: Eine monozentrische klinische Studie der Phase 1

    Directory of Open Access Journals (Sweden)

    Wang C

    2003-01-01

    Full Text Available Ein Testosteron-haltiges, hydroalkoholisches Gel wurde als wirksames und leicht anwendbares offenes System zur transdermalen Verabreichung des Hormons bei Männern entwickelt. Da das Gel sowohl auf kleine als auch auf große Hautflächen aufgetragen werden kann, sollte untersucht werden, ob die Größe der Hautfläche, auf die das Gel aufgetragen wird, ein bestimmender Faktor für die Höhe des erreichten Testosteronspiegels ist. Um dieser Frage nachzugehen, wurde die Pharmakokinetik eines transdermalen 1 %igen hydroalkoholischen Testosterongels bei neun Männern mit Hypogonadismus untersucht. Die Probanden trugen in randomisierter Reihenfolge an 7 aufeinander folgenden Tagen einmal täglich eine Dosis von 25 mg Testosteron als Gel entweder viermal an derselben Stelle (linker Arm/Schulter oder an vier verschiedenen Bezirken (linker und rechter Arm/Schultern, linker und rechter Bauch auf. Nach einer Washout-Phase von 7 Tagen wechselte dann jeder Proband für weitere 7 Behandlungstage in die andere Gruppe. Serumproben wurden zur Bestimmung von Testosteron, 5-alpha-Dihydrotestosteron (DHT und Östradiol jeweils vor, während (Tag 1, 2, 3, 5 und 7 sowie nach (Tag 8, 9, 11, 13 und 15 der Anwendung des Testosterongels abgenommen. Am 1. und 7. Tag wurden mehrfache Blutproben nach der Gelanwendung gewonnen; an den anderen Tagen wurden Einzelproben unmittelbar vor der Gelanwendung (24 h nach der vorhergehenden Anwendung abgenommen. Das Testosterongel trocknete innerhalb von 5 Minuten, hinterließ keine Rückstände und verursachte bei keinem der Probanden Hautirritationen. Die mittleren Testosteronspiegel zeigten unabhängig von der Anwendung an einer oder vier Stellen immer dasselbe Muster: Anstieg auf den zwei- bis drei- bzw. vier- bis fünffachen Ausgangswert 0,5 bzw. 24 h nach der Anwendung. Danach erreichten die Serumtestosteronspiegel den Steady-state, blieben während der Dauer der Gelanwendung beim vier- bis fünffachen Ausgangswert (im oberen

  3. Simplicity works for superfluid helium

    Energy Technology Data Exchange (ETDEWEB)

    Bowley, Roger [University of Nottingham, Nottingham (United Kingdom)

    2000-02-01

    The famous philosopher Karl Popper once said that ''science is the art of systematic oversimplification''. Indeed, when faced with a new puzzle the trick is to simplify it without losing the essential physics - something that is easier said than done. However, this approach has paid off recently in low-temperature physics. Last year Richard Packard, Seamus Davis and co-workers at the University of California at Berkeley encountered a puzzling new phenomenon in superfluid helium-3, a quantum fluid that remains a liquid close to absolute zero and exhibits unusual properties such as the ability to flow without friction (A Machenkov et al. 1999 Phys. Rev. Lett. 83 3860). Previous experiments had revealed that certain effects in liquid helium are analogous to effects observed in superconductors, materials that lose all resistance to electric current at low temperatures. When the Berkeley researchers connected two reservoirs of superfluid helium-3, the superfluid flowed back and forth through apertures that formed a ''weak link'' between the two containers. This behaviour is similar to the oscillatory current of electrons that can flow across an insulating gap separating two superconductors - a device that is known as a Josephson junction. What was puzzling about the Berkeley results was that the helium-3 had two different stable configurations, both of which behaved in an unconventional way compared with a Josephson junction. This puzzle has now been solved independently by Sidney Yip at the National Center for Theoretical Sciences in Taiwan, and by Janne Viljas and Erkki Thuneberg at the Helsinki University of Technology in Finland (Phys. Rev. Lett. 1999 83 3864 and 3868). In this article the author describes the latest research on superfluid helium. (UK)

  4. Chemical reactions studied at ultra-low temperature in liquid helium clusters

    Science.gov (United States)

    Huisken, Friedrich; Krasnokutski, Serge A.

    2012-11-01

    Low-temperature reaction rates are important ingredients for astrophysical reaction networks modeling the formation of interstellar matter in molecular clouds. Unfortunately, such data is difficult to obtain by experimental means. In an attempt to study low-temperature reactions of astrophysical interest, we have investigated relevant reactions at ultralow temperature in liquid helium droplets. Being prepared by supersonic expansion of helium gas at high pressure through a nozzle into a vacuum, large helium clusters in the form of liquid droplets constitute nano-sized reaction vessels for the study of chemical reactions at ultra-low temperature. If the normal isotope 4He is used, the helium droplets are superfluid and characterized by a constant temperature of 0.37 K. Here we present results obtained for Mg, Al, and Si reacting with O2. Mass spectrometry was employed to characterize the reaction products. As it may be difficult to distinguish between reactions occurring in the helium droplets before they are ionized and ion-molecule reactions taking place after the ionization, additional techniques were applied to ensure that the reactions actually occurred in the helium droplets. This information was provided by measuring the chemiluminescence light emitted by the products, the evaporation of helium atoms by the release of the reaction heat, or by laser-spectroscopic identification of the reactants and products.

  5. Facile time-of-flight methods for characterizing pulsed superfluid helium droplet beams.

    Science.gov (United States)

    He, Yunteng; Zhang, Jie; Li, Yang; Freund, William M; Kong, Wei

    2015-08-01

    We present two facile time-of-flight (TOF) methods of detecting superfluid helium droplets and droplets with neutral dopants. Without an electron gun and with only a heated filament and pulsed electrodes, the electron impact ionization TOF mass spectrometer can resolve ionized helium clusters such as He2(+) and He4(+), which are signatures of superfluid helium droplets. Without ionizing any helium atoms, multiphoton non-resonant laser ionization of CCl4 doped in superfluid helium droplets at 266 nm generates complex cluster ions of dopant fragments with helium atoms, including (He)(n)C(+), (He)(n)Cl(+), and (He)(n)CCl(+). Using both methods, we have characterized our cryogenic pulsed valve—the Even-Lavie valve. We have observed a primary pulse with larger helium droplets traveling at a slower speed and a rebound pulse with smaller droplets at a faster speed. In addition, the pickup efficiency of dopant is higher for the primary pulse when the nozzle temperature is higher than 13 K, and the total time duration of the doped droplet pulse is only on the order of 20 μs. These results stress the importance of fast and easy characterization of the droplet beam for sensitive measurements such as electron diffraction of doped droplets.

  6. Charging dynamics of dopants in helium nanoplasmas

    DEFF Research Database (Denmark)

    Heidenreich, Andreas; Grüner, Barbara; Schomas, Dominik

    2017-01-01

    We present a combined experimental and theoretical study of the charging dynamics of helium nanodroplets doped with atoms of different species and irradiated by intense near-infrared laser pulses (≤1015 W cm−2). In particular, we elucidate the interplay of dopant ionization inducing the ignition...... of a helium nanoplasma, and the charging of the dopant atoms driven by the ionized helium host. Most efficient nanoplasma ignition and charging is found when doping helium droplets with xenon atoms, in which case high charge states of both helium (He2+) and of xenon (Xe21+) are detected. In contrast, only low...

  7. HeREF-2003 : Helium Refrigeration Techniques

    CERN Multimedia

    2003-01-01

    CERN Technical Training 2003: Learning for the LHC ! Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2003 is a course in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2003 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2003 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. • Duration: 7 half days (4 mornings and 3 afternoons), 6-10 October, 2003 • Cost per participant: 500.- CHF ...

  8. HeREF-2003: Helium Refrigeration Techniques

    CERN Multimedia

    2003-01-01

    CERN Technical Training 2003: Learning for the LHC ! Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2003 is a course in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2003 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2003 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. Duration: 7 half days (4 mornings and 3 afternoons), 6-10 October, 2003 Cost per participant: 500.- CHF Language: Bilingual English...

  9. Phase separation of metallic hydrogen-helium alloys

    Science.gov (United States)

    Straus, D. M.; Ashcroft, N. W.; Beck, H.

    1977-01-01

    Calculations are presented for the thermodynamic functions and phase-separation boundaries of solid metallic hydrogen-helium alloys at temperatures between zero and 19,000 K and at pressures between 15 and 90 Mbar. Expressions for the band-structure energy of a randomly disordered alloy (including third order in the electron-ion interaction) are derived and evaluated. Short- and long-range orders are included by the quasi-chemical method, and lattice dynamics in the virtual-crystal harmonic approximation. It is concluded that at temperatures below 4000 K, there is essentially complete phase separation of hydrogen-helium alloys and that a miscibility gap remains at the highest temperatures and pressures considered. The relevance of these results to models of the deep interior of Jupiter is briefly discussed.

  10. Effects of helium implantation on hardness of pure iron and a reduced activation ferritic-martensitic steel

    Energy Technology Data Exchange (ETDEWEB)

    Tanigawa, Hiroyasu E-mail: tanigawa@realab01.tokai.jaeri.go.jp; Jitsukawa, Shiro; Hishinuma, Akimichi; Ando, Masami; Katoh, Yutai; Kohyama, Akira; Iwai, Takeo

    2000-12-01

    Helium was implanted into high purity Fe and F82H at room temperature up to 2000 appm to investigate helium effects on hardening. Ultra micro-indentation tests were performed on the specimens before and after helium implantation with loads that penetrate in 300 nm depth. After the indentation tests, the specimens were prepared with a focused ion beam (FIB) processing system for transmission electron microscopy (TEM) of the deformed regions. Results of the indentation tests indicated clearly that helium implantation caused hardening for both pure Fe and F82H. For pure Fe, it was also observed by TEM that the propagation of the plastic deformation zone formed during the indentation was limited to the helium-implanted layer, ranging from 600 to 800 nm from the incident surface.

  11. Helium atom scattering from surfaces

    CERN Document Server

    1992-01-01

    High resolution helium atom scattering can be applied to study a number of interesting properties of solid surfaces with great sensitivity and accuracy. This book treats in detail experimental and theoretical aspects ofthis method as well as all current applications in surface science. The individual chapters - all written by experts in the field - are devoted to the investigation of surface structure, defect shapes and concentrations, the interaction potential, collective and localized surface vibrations at low energies, phase transitions and surface diffusion. Over the past decade helium atom scattering has gained widespread recognitionwithin the surface science community. Points in its favour are comprehensiveunderstanding of the scattering theory and the availability of well-tested approximation to the rigorous theory. This book will be invaluable to surface scientists wishing to make an informed judgement on the actual and potential capabilities of this technique and its results.

  12. Using uncertainty principle to find the ground-state energy of the helium and a helium-like Hookean atom

    Energy Technology Data Exchange (ETDEWEB)

    Harbola, Varun, E-mail: varunh@iitk.ac.in [Kendriya Vidyalaya (Central School) Indian Institute of Technology, Kanpur-208 016 (India)

    2011-11-15

    In this paper, we accurately estimate the ground-state energy and the atomic radius of the helium atom and a helium-like Hookean atom by employing the uncertainty principle in conjunction with the variational approach. We show that with the use of the uncertainty principle, electrons are found to be spread over a radial region, giving an electron cloud. Our calculation also shows how the Coulomb interaction between electrons affects their distribution. This leads to a physical picture of how electrons are located with respect to each other in these atoms. Finally, we also obtain through our calculations a general formula for the estimate of ground-state energy and radius of two electron atoms and ions with atomic number Z.

  13. Investigations of levitated helium drops

    Science.gov (United States)

    Whitaker, Dwight Lawrence

    1999-11-01

    We report on the development of two systems capable of levitating drops of liquid helium. Helium drops of ˜20 mum have been levitated with the radiation pressure from two counter-propagating Nd:YAG laser beams. Drops are produced with a submerged piezoelectric transducer, and could be held for up to three minutes in our optical trap. Calculations show that Brillouin and Raman scattering of the laser light in the liquid helium produces a negligible rate of evaporation of the drop. Evaporation caused by the enhanced vapor pressure of the curved drop surfaces appears to be a significant effect limiting the drop lifetimes. Helium drops as large as 2 cm in diameter have been suspended in the earth's gravitational field with a magnetic field. A commercial superconducting solenoid provides the necessary field, field-gradient product required to levitate the drops. Drops are cooled to 0.5 K with a helium-3 refrigerator, and can be held in the trap indefinitely. We have found that when two or more drops are levitated in the same magnetic trap, the drops often remain in a state of apparent contact without coalescing. This effect is a result of the evaporation of liquid from between the two drops, and is found to occur only for normal fluid drops. We can induce shape oscillations in charged, levitated drops with an applied ac electric field. We have measured the resonance frequencies and damping rates for the l = 2 mode of oscillation as function of temperature. We have also developed a theory to describe the small amplitude shape oscillations of a He II drop surrounded by its saturated vapor. In our theory, we have considered two sets of boundary conditions---one where the drop does not evaporate and another in which the liquid and vapor are in thermodynamic equilibrium. We have found that both solutions give a frequency that agrees well with experiment, but that the data for the damping rate agree better with the solution without evaporation.

  14. The mean excitation energy of atomic ions

    DEFF Research Database (Denmark)

    Sauer, Stephan P. A.; Oddershede, Jens; Sabin, John R.

    2015-01-01

    A method for calculation of the mean excitation energies of atomic ions is presented, making the calculation of the energy deposition of fast ions to plasmas, warm, dense matter, and complex biological systems possible. Results are reported to all ions of helium, lithium, carbon, neon, aluminum, ...

  15. Thermodynamic properties of hydrogen-helium plasmas.

    Science.gov (United States)

    Nelson, H. F.

    1972-01-01

    Calculation of the thermodynamic properties of an atomic hydrogen-helium plasma for postulated conditions present in a stagnation shock layer of a spacecraft entering the atmosphere of Jupiter. These properties can be used to evaluate transport properties, to calculate convective heating, and to investigate nonequilibrium behavior. The calculations have been made for temperatures from 10,000 to 100,000 K, densities of 10 to the minus 7th and .00001 g cu cm, and three plasma compositions: pure hydrogen, 50% hydrogen/50% helium, and pure helium. The shock layer plasma consists of electrons, protons, atomic hydrogen, atomic helium, singly ionized helium, and doubly atomized helium. The thermodynamic properties which have been investigated are: pressure, average molecular weight, internal energy, enthalpy, entropy, specific heat, and isentropic speed of sound. A consistent model was used for the reduction of the ionization potential in the calculation of the partition functions.

  16. Critical Landau velocity in helium nanodroplets.

    Science.gov (United States)

    Brauer, Nils B; Smolarek, Szymon; Loginov, Evgeniy; Mateo, David; Hernando, Alberto; Pi, Marti; Barranco, Manuel; Buma, Wybren J; Drabbels, Marcel

    2013-10-11

    The best-known property of superfluid helium is the vanishing viscosity that objects experience while moving through the liquid with speeds below the so-called critical Landau velocity. This critical velocity is generally considered a macroscopic property as it is related to the collective excitations of the helium atoms in the liquid. In the present work we determine to what extent this concept can still be applied to nanometer-scale, finite size helium systems. To this end, atoms and molecules embedded in helium nanodroplets of various sizes are accelerated out of the droplets by means of optical excitation, and the speed distributions of the ejected particles are determined. The measurements reveal the existence of a critical velocity in these systems, even for nanodroplets consisting of only a thousand helium atoms. Accompanying theoretical simulations based on a time-dependent density functional description of the helium confirm and further elucidate this experimental finding.

  17. Ras Laffan helium recovery unit 2

    Science.gov (United States)

    Fauve, Eric Arnaud; Grabié, Veronique; Grillot, David; Delcayre, Franck; Deschildre, Cindy

    2012-06-01

    In May 2010, Air Liquide was awarded a contract for the Engineering Procurement and Construction (Turnkey EPC) for a second helium recovery unit [RLH II] dedicated to the Ras Laffan refinery in Qatar. This unit will come in addition to the one [RLH I] delivered and commissioned by Air Liquide in 2005. It will increase the helium production of Qatar from 10% to 28% of worldwide production. RLH I and RLH II use Air Liquide Advanced Technologies helium liquefiers. With a production of 8 tons of liquid helium per day, the RLH I liquefier is the world largest, but not for long. Thanks to the newly developed turbine TC7, Air Liquide was able to propose for RLH II a single liquefier able to produce over 20 tons per day of liquid helium without liquid nitrogen pre-cooling. This liquefier using 6 Air Liquide turbines (TC series) will set a new record in the world of helium liquefaction.

  18. Am Puls des Wandels - Veränderungskommunikation messen und steuern : Entwicklung und Anwendung eines Controllingansatzes für Veränderungskommunikation.

    OpenAIRE

    Heyder, Daniela

    2014-01-01

    Die Zielsetzung der Arbeit liegt in der Entwicklung und empirischen Anwendung eines Controllingansatzes speziell für die Veränderungskommunikation. Für den Erfolg eines Unternehmens ist kontinuierlicher Wandel von zentraler Bedeutung. So schnell wie sich die Umwelt durch z.B. zunehmenden Wettbewerb, neue Wertvorstellungen oder innovative Technologien verändert, müssen sich die Strategien, Strukturen und Prozesse in Unternehmen sowie immer auch die Mitarbeiter, ihre Denk- und Verhaltensweis...

  19. Parameters of helium absorption by porous structures

    Science.gov (United States)

    Bukin, A. N.; Ivanova, A. S.; Marunich, S. A.; Pak, Yu. S.; Rozenkevich, M. B.

    2017-05-01

    Results from investigating the parameters of helium absoption by hollow glass-crystalline cenospheres obtained at the Reftinsky regional power station in the city of Asbest are presented. The permeability coefficients of helium penetrating through shells are determined, and the apparent activation energy is estimated ( E act = 33 ± 5 kJ/mol). The possibility of selectively extracting helium from mixtures of it and nitrogen is shown.

  20. Surface Impact Simulations of Helium Nanodroplets

    Science.gov (United States)

    2015-06-30

    AFRL-RW-EG-TP-2015-001 Surface Impact Simulations of Helium Nanodroplets Robert J. Hinde Department of Chemistry University of...TITLE AND SUBTITLE Surface Impact Simulations of Helium Nanodroplets 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA8651-11-1-0005 5c. PROGRAM ELEMENT...captures atomic delocalization of the helium atoms characteristic of the quantum solvent, but allow the single-particle wavefunctions to vary throughout

  1. Behaviour of helium after implantation in molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    Viaud, C. [Commissariat a l' Energie Atomique (CEA), Cadarache (France)], E-mail: viaud@dircad.cea.fr; Maillard, S.; Carlot, G.; Valot, C. [Commissariat a l' Energie Atomique (CEA), Cadarache (France); Gilabert, E. [Chimie Nucleaire Analytique and Bio-environnementale (CNAB), Gradignan (France); Sauvage, T. [CEMHTI-CNRS, Orleans (France); Peaucelle, C.; Moncoffre, N. [Institut de Physique Nucleaire de Lyon (IPNL), Lyon (France)

    2009-03-31

    This study deals with the behaviour of helium in a molybdenum liner dedicated to the retention of fission products. More precisely this work contributes to evaluate the release of implanted helium when the gas has precipitated into nanometric bubbles close to the free surface. A simple model dedicated to calculate the helium release in such a condition is presented. The specificity of this model lays on the assumption that the gas is in equilibrium with a simple distribution of growing bubbles. This effort is encouraging since the calculated helium release fits an experimental dataset with a set of parameters in good agreement with the literature.

  2. Helium resources of the United States, 1989

    Science.gov (United States)

    Miller, Richard D.; Hamak, John E.

    The helium resources base of the United States was estimated by the Bureau of Mines to be 894.6 Bcf as of January 1, 1989. These resources are divided into four categories in decreasing degree of the assurance of their existence: (1) helium in storage and in proved natural gas reserves, 282.4 Bcf; (2) helium in probable natural gas resources, estimated at 237.7 Bcf; (3) helium in possible natural gas resources, estimated to be 263.2 Bcf; and (4) helium in speculative natural gas resources, 111.4 Bcf. These helium resources are further divided into depleting and nondepleting, with the helium in storage being in a separate classification. The depleting resources are those associated with natural gasfields that are, or will be, produced for the natural gas they contain. Almost all of the helium in potential (probable, possible, and speculative) natural gas resources is included in this classification. These depleting resources are estimated to contain 775 Bcf of the total helium resource base.

  3. Vacancy-type defects and hardness of helium implanted CLAM steel studied by positron-annihilation spectroscopy and nano-indentation technique

    Energy Technology Data Exchange (ETDEWEB)

    Xin Yong [Department of Physics, University of Science and Technology Beijing, Beijing 100083 (China); Ju Xin, E-mail: jux@ustb.edu.cn [Department of Physics, University of Science and Technology Beijing, Beijing 100083 (China); Qiu Jie [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Guo Liping; Chen Jihong; Yang Zheng [Accelerator Laboratories, School of Physics, Wuhan University, Wuhan, Hubei 430072 (China); Zhang Peng; Cao Xinzhong; Wang Baoyi [Key Laboratory of Nuclear Analysis Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer Helium implantation is performed to CLAM steel at different temperatures. Black-Right-Pointing-Pointer Positron annihilation is used to investigate vacancy-type defects. Black-Right-Pointing-Pointer Nano-hardness is investigated to study irradiation induced hardening. Black-Right-Pointing-Pointer Vacancy-helium complexes are main defects after implantation. Black-Right-Pointing-Pointer Both helium-vacancy clusters and helium bubbles contribute to hardening. - Abstract: China Low Activation Martensitic (CLAM) steel was implanted with helium up to 1e + 16/cm{sup 2} at 300-873 K using 140 keV helium ions. Vacancy-type defects induced by implantation were investigated with positron beam Doppler broadening technique, and then nano-hardness measurements were performed to investigate helium-induced hardening effect. He implantation produced a large number of vacancy-type defects in CLAM steel, and the concentration of vacancy-type defects decreased with increasing temperature. Vacancy-helium complexes were main defects at different temperatures. Irradiation induced hardening was observed at all irradiation temperatures, and the peak value of hardness was at 473 K. The result suggested that both vacancy-helium complexes and helium bubbles had contribution to irradiation induced hardening. The decomposition and annihilation of irradiation-induced defects became more and more significant with increasing temperature, which induced the increment of hardness became more and more small.

  4. Scaling of cross-sections for asymmetric (e, 3e) process on helium ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 63; Issue 5. Scaling of ... An approximate simple scaling law is obtained for asymmetric (, 3) process on helium-like ions for double ionization by fast electrons. ... The scaling law becomes increasingly accurate as the target nuclear charge and the energy increase.

  5. Helium, Iron and Electron Particle Transport and Energy Transport Studies on the TFTR Tokamak

    Science.gov (United States)

    Synakowski, E. J.; Efthimion, P. C.; Rewoldt, G.; Stratton, B. C.; Tang, W. M.; Grek, B.; Hill, K. W.; Hulse, R. A.; Johnson, D .W.; Mansfield, D. K.; McCune, D.; Mikkelsen, D. R.; Park, H. K.; Ramsey, A. T.; Redi, M. H.; Scott, S. D.; Taylor, G.; Timberlake, J.; Zarnstorff, M. C. (Princeton Univ., NJ (United States). Plasma Physics Lab.); Kissick, M. W. (Wisconsin Univ., Madison, WI (United States))

    1993-03-01

    Results from helium, iron, and electron transport on TFTR in L-mode and Supershot deuterium plasmas with the same toroidal field, plasma current, and neutral beam heating power are presented. They are compared to results from thermal transport analysis based on power balance. Particle diffusivities and thermal conductivities are radially hollow and larger than neoclassical values, except possibly near the magnetic axis. The ion channel dominates over the electron channel in both particle and thermal diffusion. A peaked helium profile, supported by inward convection that is stronger than predicted by neoclassical theory, is measured in the Supershot The helium profile shape is consistent with predictions from quasilinear electrostatic drift-wave theory. While the perturbative particle diffusion coefficients of all three species are similar in the Supershot, differences are found in the L-Mode. Quasilinear theory calculations of the ratios of impurity diffusivities are in good accord with measurements. Theory estimates indicate that the ion heat flux should be larger than the electron heat flux, consistent with power balance analysis. However, theoretical values of the ratio of the ion to electron heat flux can be more than a factor of three larger than experimental values. A correlation between helium diffusion and ion thermal transport is observed and has favorable implications for sustained ignition of a tokamak fusion reactor.

  6. Plasma action on helium flow in cold atmospheric pressure plasma jet experiments

    Science.gov (United States)

    Darny, T.; Pouvesle, J.-M.; Fontane, J.; Joly, L.; Dozias, S.; Robert, E.

    2017-10-01

    In this work, helium flow modifications, visualized by schlieren imaging, induced by the plasma generated in a plasma jet have been studied in conditions used for biomedical treatments (jet being directed downwards with a low helium flow rate). It has been shown that the plasma action can shift up to few centimeters downstream the effects of buoyancy, which allows to the helium flow to reach a target below in conditions for which it is not the case when the plasma is off. This study reveals the critical role of large and long lifetime negative ions during repetitive operations in the kHz regime, inducing strong modifications in the gas propagation. The cumulative added streamwise momentum transferred to ambient air surrounding molecules resulting from a series of applied voltage pulses induces a gradual built up of a helium channel on tens of millisecond timescale. In some conditions, a remarkable stable cylindrical helium channel can be generated to the target with plasma supplied by negative polarity voltage pulses whereas a disturbed flow results from positive polarity operation. This has a direct effect on air penetration in the helium channel and then on the reactive species production over the target which is of great importance for biomedical applications. It has also been shown that with an appropriate combination of negative and positive polarity pulses, it is possible to benefit from both polarity features in order to optimize the plasma plume propagation and plasma delivery to a target.

  7. Fabrication of semiconductor microspheres with laser ablation in superfluid helium

    Science.gov (United States)

    Minowa, Yosuke; Oguni, Yuya; Ashida, Masaaki

    2017-04-01

    We fabricated semiconductor ZnO microspheres via the pulsed laser ablation in the superfluid helium. The scanning electron microscope observation revealed the high sphericity and smooth surface. We also observed whispering gallery mode resonances, the electromagnetic eigenmode resonances within the microspheres, in the cathodoluminescence spectrum, verifying the high symmetry of the fabricated microspheres. Further, we cross-sectioned the microspheres with using focused ion beam. The scanning electron microscope observation of the cross section uncovers the existence of small holes within the microspheres. The inner structure examination helps us to understand the microscopic mechanism of our fabrication method.

  8. Explosive Hydrogen and Helium Burning in Astrophysical Events.

    Science.gov (United States)

    Wallace, Richard Kent

    The nuclear energy generation and nucleosynthesis that occur in hydrogen-rich compositions at temperatures substantially greater than 10('8) K are examined in detail. At these high temperatures, a new kind of nucleosynthetic process (the "rp-process") involving the rapid capture of protons on seed nuclei (or on the products of helium burning in a situation with zero initial metallicity) can lead to the production of heavy elements up to and beyond the iron group with an accompanying energy generation rate greatly modified from that of the (beta)-limited CNO cycle customarily employed in such calculations. New nuclear reaction rates of interest are tabulated, and reaction network calculations are presented to illustrate the application of this process to exploding supermassive stars, accreting neutron stars, novae, and certain chaotic cosmologies. Implications for (gamma)-line astronomy and x-ray burst models are discussed. To further explore the importance of thermonuclear instabilities for accreting neutron stars, the evolution of a 1.41 M(,(CIRCLE)) neutron star accreting both solar and metal-deficient mixtures of hydrogen, helium, and heavy elements at rates ranging from about 10('-11) to 10('-10) M(,(CIRCLE)) per year is examined using a one-dimensional numerical model. The metal deficient compositions may result either from placement of the neutron star in a binary system with a Population II Red Giant or from gravitational settling of heavy ions in the accreted material. For such accretion rates and metallicities, hydrogen burning, mediated by the (beta)-limited CNO cycle, is stable and leads to the accumulation of a thick helium layer with mass 10('23) to 10('25) g and temperature 0.7 (LESSTHEQ) T(,8) (LESSTHEQ) 1.2. Helium ignition occurs under extremely degenerate circumstances and is catastrophically violent. In the lower mass helium shells this runaway is propagated as a convective deflagration; for the thicker layers a detonation front is set up which

  9. Rydberg States of Alkali Metal Atoms on Superfluid Helium Droplets - Theoretical Considerations

    Science.gov (United States)

    Pototschnig, Johann V.; Lackner, Florian; Hauser, Andreas W.; Ernst, Wolfgang E.

    2017-06-01

    The bound states of electrons on the surface of superfluid helium have been a research topic for several decades. One of the first systems treated was an electron bound to an ionized helium cluster. Here, a similar system is considered, which consists of a helium droplet with an ionized dopant inside and an orbiting electron on the outside. In our theoretical investigation we select alkali metal atoms (AK) as central ions, stimulated by recent experimental studies of Rydberg states for Na, Rb, and Cs attached to superfluid helium nanodroplets. Experimental spectra , obtained by electronic excitation and subsequent ionization, showed blueshifts for low lying electronic states and redshifts for Rydberg states. In our theoretical treatment the diatomic AK^+-He potential energy curves are first computed with ab initio methods. These potentials are then used to calculate the solvation energy of the ion in a helium droplet as a function of the number of atoms. Additional potential terms, derived from the obtained helium density distribution, are added to the undisturbed atomic pseudopotential in order to simulate a 'modified' potential felt by the outermost electron. This allows us to compute a new set of eigenstates and eigenenergies, which we compare to the experimentally observed energy shifts for highly excited alkali metal atoms on helium nanodroplets. A. Golov and S. Sekatskii, Physica B, 1994, 194, 555-556 E. Loginov, C. Callegari, F. Ancilotto, and M. Drabbels, J. Phys. Chem. A, 2011, 115, 6779-6788 F. Lackner, G. Krois, M. Koch, and W. E. Ernst, J. Phys. Chem. Lett., 2012, 3, 1404-1408 F. Lackner, G. Krois, M. Theisen, M. Koch, and W. E. Ernst, Phys. Chem. Chem. Phys., 2011, 13, 18781-18788

  10. The helium-graphite interaction

    Energy Technology Data Exchange (ETDEWEB)

    Joly, F.; Lhuillier, C.; Brami, B. (Lab. de Physique Theorique des Liquides, Univ. Pierre et Marie Curie, 75 - Paris (France))

    1992-03-15

    We propose a very simple empirical form of the helium-on-graphite potential, which reproduces the energy of the six known bound states, the experimental average distance of the {sup 4}He atom from the surface in the ground state and the correct asymptotic behaviour of the interaction. This optimized potential is used to compute the binding energy of a {sup 3}He atom on the same substrate. The agreement between the theoretical predictions and the experimental results is a check of the set of variational parameters. (orig.).

  11. Helium transfer line installation details.

    CERN Multimedia

    G. Perinic

    2007-01-01

    A particularity of the 32 m long four in one helium transfer line in between the cold box in USC55 and the cavern UX5 is the fact that the transfer line passes through a hole in the crane rail support beam. In order to ensure the alignment of the suspension rail in the interconnecting tunnel with the hole in the rail support as well as the connection points at both ends required precise measurements of the given geometries as well as the installation of a temporary target for the verification of the theoretical predictions.

  12. Development of a Polarized Helium-3 Source for RHIC and eRHIC

    Science.gov (United States)

    Maxwell, J.; Epstein, C.; Milner, R.; Alessi, J.; Beebe, E.; Pikin, A.; Ritter, J.; Zelenski, A.

    2016-02-01

    The addition of a polarized 3He ion source for use at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory would enable a host of new measurements, particularly in the context of a planned eRHIC. We are developing such a source using metastability exchange optical pumping to polarize helium-3, which will be then transferred into RHIC’s Electron Beam Ion Source for ionization. We aim to deliver nuclear polarization of near 70%, and roughly 1011 doubly-ionized 3He++ ions will be created in each 20 μsec pulse. We discuss the design of the source, and the status of its development.

  13. LOX Tank Helium Removal for Propellant Scavenging

    Science.gov (United States)

    Chato, David J.

    2009-01-01

    System studies have shown a significant advantage to reusing the hydrogen and oxygen left in these tanks after landing on the Moon in fuel cells to generate power and water for surface systems. However in the current lander concepts, the helium used to pressurize the oxygen tank can substantially degrade fuel cell power and water output by covering the reacting surface with inert gas. This presentation documents an experimental investigation of methods to remove the helium pressurant while minimizing the amount of the oxygen lost. This investigation demonstrated that significant quantities of Helium (greater than 90% mole fraction) remain in the tank after draining. Although a single vent cycle reduced the helium quantity, large amounts of helium remained. Cyclic venting appeared to be more effective. Three vent cycles were sufficient to reduce the helium to small (less than 0.2%) quantities. Two vent cycles may be sufficient since once the tank has been brought up to pressure after the second vent cycle the helium concentration has been reduced to the less than 0.2% level. The re-pressurization process seemed to contribute to diluting helium. This is as expected since in order to raise the pressure liquid oxygen must be evaporated. Estimated liquid oxygen loss is on the order of 82 pounds (assuming the third vent cycle is not required).

  14. Helium-cooled high temperature reactors

    Energy Technology Data Exchange (ETDEWEB)

    Trauger, D.B.

    1985-01-01

    Experience with several helium cooled reactors has been favorable, and two commercial plants are now operating. Both of these units are of the High Temperature Graphite Gas Cooled concept, one in the United States and the other in the Federal Republic of Germany. The initial helium charge for a reactor of the 1000 MW(e) size is modest, approx.15,000 kg.

  15. Organ protection by the noble gas helium

    NARCIS (Netherlands)

    Smit, K.F.

    2017-01-01

    The aims of this thesis were to investigate whether helium induces preconditioning in humans, and to elucidate the mechanisms behind this possible protection. First, we collected data regarding organ protective effects of noble gases in general, and of helium in particular (chapters 1-3). In chapter

  16. Helium Speech: An Application of Standing Waves

    Science.gov (United States)

    Wentworth, Christopher D.

    2011-01-01

    Taking a breath of helium gas and then speaking or singing to the class is a favorite demonstration for an introductory physics course, as it usually elicits appreciative laughter, which serves to energize the class session. Students will usually report that the helium speech "raises the frequency" of the voice. A more accurate description of the…

  17. Permeability of Hollow Microspherical Membranes to Helium

    Science.gov (United States)

    Zinoviev, V. N.; Kazanin, I. V.; Pak, A. Yu.; Vereshchagin, A. S.; Lebiga, V. A.; Fomin, V. M.

    2016-01-01

    This work is devoted to the study of the sorption characteristics of various hollow microspherical membranes to reveal particles most suitable for application in the membrane-sorption technologies of helium extraction from a natural gas. The permeability of the investigated sorbents to helium and their impermeability to air and methane are shown experimentally. The sorption-desorption dependences of the studied sorbents have been obtained, from which the parameters of their specific permeability to helium are calculated. It has been established that the physicochemical modification of the original particles exerts a great influence on the coefficient of the permeability of a sorbent to helium. Specially treated cenospheres have displayed high efficiency as membranes for selective extraction of helium.

  18. Helium bubble formation in ultrafine and nanocrystalline tungsten under different extreme conditions

    Energy Technology Data Exchange (ETDEWEB)

    El-Atwani, O. [School of Nuclear Engineering, Purdue University, West Lafayette, IN 47907 (United States); School of Materials Engineering, Purdue University, West Lafayette, IN 47907 (United States); Birck Nanotechnology Center, West Lafayette, IN 47907 (United States); Center of Materials Under Extreme Environment, West Lafayette, IN 47907 (United States); Hattar, K. [Department of Radiation Solid Interactions, Sandia National Laboratories, Albuquerque, NM 87185 (United States); Hinks, J.A.; Greaves, G. [School of Computing and Engineering, University of Huddersfield, HD1 3DH (United Kingdom); Harilal, S.S. [School of Nuclear Engineering, Purdue University, West Lafayette, IN 47907 (United States); Center of Materials Under Extreme Environment, West Lafayette, IN 47907 (United States); Pacific Northwest National Laboratory, P.O. Box 999, Richland, WA 99352 (United States); Hassanein, A. [School of Nuclear Engineering, Purdue University, West Lafayette, IN 47907 (United States); Center of Materials Under Extreme Environment, West Lafayette, IN 47907 (United States)

    2015-03-15

    Graphical abstract: Bright-field TEM micrographs of UFG and NC tungsten irradiated with 2 keV helium ions (flux of 3.3 × 10{sup 16} ions m{sup −2} s{sup −1}) at 1223 K demonstrating: (a) overview of sample with bubbles decorating grain boundaries at a fluence of 3.6 × 10{sup 19} ions m{sup −2}; (b) nanocrystalline grain with large facetted bubbles/voids on grain boundaries and few bubbles in the grain matrix at a fluence of 3.6 × 10{sup 19} ions m{sup −2}; and (c) grain boundary and (d) grain boundary triple-junction decorated by facetted bubbles with different sizes inside ultrafine grains at fluence of 4.0 × 10{sup 20} ions m{sup −2}. - Highlights: • Helium ion irradiation was performed on ultrafine grained and nanocrystalline tungsten. • Irradiations were performed at different extreme conditions. • Bubble formation and evolution were performed via ex-situ and in-situ TEM. • Preferential bubble formation on grain boundaries occurred at displacement energies and high temperatures. • Vacancy formation and migration is important for preferential bubble formation on grain boundaries. - Abstract: We have investigated the effects of helium ion irradiation energy and sample temperature on the performance of grain boundaries as helium sinks in ultrafine grained and nanocrystalline tungsten. Irradiations were performed at displacement and non-displacement energies and at temperatures above and below that required for vacancy migration. Microstructural investigations were performed using Transmission Electron Microscopy (TEM) combined with either in-situ or ex-situ ion irradiation. Under helium irradiation at an energy which does not cause atomic displacements in tungsten (70 eV), regardless of temperature and thus vacancy migration conditions, bubbles were uniformly distributed with no preferential bubble formation on grain boundaries. At energies that can cause displacements, bubbles were observed to be preferentially formed on the grain

  19. Exotic helium molecules; Molecules exotiques d'helium

    Energy Technology Data Exchange (ETDEWEB)

    Portier, M

    2007-12-15

    We study the photo-association of an ultracold cloud of magnetically trapped helium atoms: pairs of colliding atoms interact with one or two laser fields to produce a purely long range {sup 4}He{sub 2}(2{sup 3}S{sub 1}-2{sup 3}P{sub 0}) molecule, or a {sup 4}He{sub 2}(2{sup 3}S{sub 1}-2{sup 3}S{sub 1}) long range molecule. Light shifts in one photon photo-association spectra are measured and studied as a function of the laser polarization and intensity, and the vibrational state of the excited molecule. They result from the light-induced coupling between the excited molecule, and bound and scattering states of the interaction between two metastable atoms. Their analysis leads to the determination of the scattering length a = (7.2 {+-} 0.6) ruling collisions between spin polarized atoms. The two photon photo-association spectra show evidence of the production of polarized, long-range {sup 4}He{sub 2}(2{sup 3}S{sub 1}-2{sup 3}S{sub 1}) molecules. They are said to be exotic as they are made of two metastable atoms, each one carrying a enough energy to ionize the other. The corresponding lineshapes are calculated and decomposed in sums and products of Breit-Wigner and Fano profiles associated to one and two photon processes. The experimental spectra are fit, and an intrinsic lifetime {tau} = (1.4 {+-} 0.3) {mu}s is deduced. It is checked whether this lifetime could be limited by spin-dipole induced Penning autoionization. This interpretation requires that there is a quasi-bound state close to the dissociation threshold in the singlet interaction potential between metastable helium atoms for the theory to match the experiment. (author)

  20. On the stability of cationic complexes of neon with helium--solving an experimental discrepancy.

    Science.gov (United States)

    Bartl, Peter; Denifl, Stephan; Scheier, Paul; Echt, Olof

    2013-10-21

    Helium nanodroplets are doped with neon and ionized by electrons. The size-dependence of the ion abundance of HenNex(+), identified in high-resolution mass spectra, is deduced for complexes containing up to seven neon atoms and dozens of helium atoms. Particularly stable ions are inferred from anomalies in the abundance distributions. Two pronounced anomalies at n = 11 and 13 in the HenNe(+) series confirm drift-tube data reported by Kojima et al. [T. M. Kojima et al., Z. Phys. D, 1992, 22, 645]. The discrepancy with previously published spectra of neon-doped helium droplets, which did not reveal any abundance anomalies [T. Ruchti et al., J. Chem. Phys., 1998, 109, 10679-10687; C. A. Brindle et al., J. Chem. Phys., 2005, 123, 064312], is most likely due to limited mass resolution, which precluded unambiguous analysis of contributions from different ions with identical nominal mass. However, calculated dissociation energies of HenNe(+) reported so far do not correlate with the present data, possibly because of challenges in correctly treating the linear, asymmetric [He-Ne-He](+) ionic core in HenNe(+). Anomalies identified in the distributions of HenNex(+) for x > 1, including prominent ones at He12Ne2(+) and He14Ne2(+), may help to better understand solvation of Ne(+) and Nex(+) in helium.

  1. FINAL TECHNICAL REPORT FOR DE-FG02-05ER64097 Systems and Methods for Injecting Helium Beams into a Synchrotron Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Bush, David A

    2008-09-30

    A research grant was approved to fund development of requirements and concepts for extracting a helium-ion beam at the LLUMC proton accelerator facility, thus enabling the facility to better simulate the deep space environment via beams sufficient to study biological effects of accelerated helium ions in living tissues. A biologically meaningful helium-ion beam will be accomplished by implementing enhancements to increase the accelerator's maximum proton beam energy output from 250MeV to 300MeV. Additional benefits anticipated from the increased energy include the capability to compare possible benefits from helium-beam radiation treatment with proton-beam treatment, and to provide a platform for developing a future proton computed tomography imaging system.

  2. Neoclassical flows in deuterium-helium plasma density pedestals

    CERN Document Server

    Buller, Stefan; Newton, Sarah; Omotani, John

    2016-01-01

    In tokamak transport barriers, the radial scale of profile variations can be comparable to a typical ion orbit width, which makes the coupling of the distribution function across flux surfaces important in the collisional dynamics. We use the radially global steady-state neoclassical {\\delta}f code Perfect to calculate poloidal and toroidal flows, and radial fluxes, in the pedestal. In particular, we have studied the changes in these quantities as the plasma composition is changed from a deuterium bulk species with a helium impurity to a helium bulk with a deuterium impurity, under specific profile similarity assumptions. The poloidally resolved radial fluxes are not divergence-free in isolation in the presence of sharp radial profile variations, which leads to the appearance of poloidal return-flows. These flows exhibit a complex radial-poloidal structure that extends several orbit widths into the core and is sensitive to abrupt radial changes in the ion temperature gradient. We find that a sizable neoclassi...

  3. Helium Detonations on Neutron Stars

    Science.gov (United States)

    Zingale, M.; Timmes, F. X.; Fryxell, B.; Lamb, D. Q.; Olson, K.; Calder, A. C.; Dursi, L. J.; Ricker, P.; Rosner, R.; Truran, J. W.; MacNeice, P.; Tufo, H.

    2000-05-01

    We present the results of a numerical study of helium detonations on the surfaces of neutron stars. We analyze the evolution of a detonation as it breaks through the envelope of the neutron star and propagates across its surface. A series of surface waves propagate across the pool of hot ash with a speed of 1.3 x 109 \\ cm \\ s-1, matching the speed expected from shallow water wave theory. The entire envelope bounces in the gravitational potential well of the neutron star with a period of 50 μ s. The photosphere reaches a height of 15 km above the surface of the neutron star. The sensitivity of the results to the spatial resolution and assumed initial conditions are analyzed, and the relevance of this model to Type I X-ray bursts is discussed. This work is supported by the Department of Energy under Grant No. B341495 to the Center for Astrophysical Thermonuclear Flashes at the University of Chicago.

  4. Electric response in superfluid helium

    Science.gov (United States)

    Chagovets, Tymofiy V.

    2016-05-01

    We report an experimental investigation of the electric response of superfluid helium that arises in the presence of a second sound standing wave. It was found that the signal of the electric response is observed in a narrow range of second sound excitation power. The linear dependence of the signal amplitude has been derived at low excitation power, however, above some critical power, the amplitude of the signal is considerably decreased. It was established that the rapid change of the electric response is not associated with a turbulent regime generated by the second sound wave. A model of the appearance of the electric response as a result of the oscillation of electron bubbles in the normal fluid velocity field in the second sound wave is presented. Possible explanation for the decrease of the electric response are presented.

  5. Study of damage and helium diffusion in fluoro-apatites; Etude de l'endommagement et de la diffusion de l'helium dans des fluoroapatites

    Energy Technology Data Exchange (ETDEWEB)

    Miro, S

    2004-12-15

    This work lies within the scope of the study of the radionuclides containment matrices. The choice of the fluoro-apatites as potential matrices of containment was suggested by the notable properties of these latter (thermal and chemical stability even under radioactive radiation). By irradiations with heavy ions and a helium implantation we simulated the effects related to the alpha radioactivity and to the spontaneous nuclear fission of the radionuclides. Thanks to the study of Durango fluoro-apatite single crystals and fluoro-apatite sintered ceramics, we evidenced that the damage fraction as well as the unit cell deformations increase with the electronic energy loss and with the substitution. These effects are followed at high fluences by a phenomenon of re-crystallization. The study of the helium diffusion points out that the thermal diffusion process improves with the substitution and strongly increases with heavy ions irradiation. (author)

  6. Weldability of helium-containing stainless steels using a YAG laser

    Science.gov (United States)

    Kawano, S.; Nakahigashi, S.; Uesugi, K.; Nakamura, H.; Kono, W.; Fukuya, K.; Kano, F.; Hasegawa, A.; Abe, K.

    1998-10-01

    Bead-on-plate welding experiments using a 400 W YAG laser were conducted on SUS304 stainless steels implanted with helium ions of 0.5, 5 and 50 appm uniformly to a depth of 0.25 mm. High heat input welding at 20 kJ/cm caused surface grain boundary cracking in the heat-affected zone at 50 appm He. Cross-sectional observations after etching in oxalic acid solution revealed that bubble growth at grain boundaries in the heat-affected zone was enhanced at higher heat input and at higher helium concentrations. Bubble growth was negligible for the laser welding condition of 1 kJ/cm even at 50 appm He. The results suggest that YAG laser welding is a promising welding technique for stainless steels containing high amounts of helium.

  7. The investigation of inertial fusion burning requirements of deuterium-helium3 in degenerate plasma

    Science.gov (United States)

    Nazirzadeh, M.; Khanbabaei, B.; Ghasemizad, A.

    2017-08-01

    Conditions for self-sustained burning of deuterium-helium3 as an advanced fuel in a degenerate regime have been investigated by the four temperature theory. The four temperature theory can describe the radiation field more accurately than the three temperature model. According to the four temperature theory, the photon distribution undergoes a transition from an optically thick to optically thin regime at a certain cut-off energy. The main goal of this research is to determine the critical burn-up parameter for deuterium-helium3 fuel in the degenerate regime in which the ion-electron energy exchange and the bremsstrahlung loss are smaller than those of the classic plasma. To prevent high tritium breeding via deuterium-deuterium and deuterium-tritium reactions, the utilization of equimolar deuterium-helium3 fuel is avoided.

  8. Effects of low energy helium plasma irradiation on potassium doped tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Xiaoyan [Key Laboratory of Radiation Physics and Technology of Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu (China); Key Subject Laboratory of National Defense for Radioactive Waste and Environmental Security, Southwest University of Science and Technology, Mianyang (China); Huang, Bo [Key Laboratory of Radiation Physics and Technology of Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu (China); Liu, Dongping; Fan, Hongyu [School of Physics and Materials Engineering, Dalian Nationalities University, Dalian (China); Liu, Ning [Key Laboratory of Radiation Physics and Technology of Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu (China); Tang, Jun, E-mail: tangjun@scu.edu.cn [Key Laboratory of Radiation Physics and Technology of Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu (China)

    2017-04-15

    Effects of helium plasma irradiation on spark plasma sintering (SPS) W-K, pure W and traditionally sintered commercial W-K have been studied, concerning the density, grain size and potassium content as the influence factors. Pinholes are formed under 120 eV He ions at 600 °C and 1 × 10{sup 23} m{sup −2} fluence on the surface of all samples. It is found that SPS-sintered W-K shows the best irradiation resistance among the present samples, and SPS-sintered pure W exhibits higher irradiation tolerance than commercial W-K. Different He-plasma tolerance was observed among the SPS-sintered W-K samples due to varied potassium content and grain size. In addition, the microstructure evolution under helium irradiation, the growth-migration of helium bubbles and their interactions of potassium bubbles have also been discussed.

  9. Helium implanted AlHf as studied by Ta TDPAC

    Indian Academy of Sciences (India)

    Unknown

    TDPAC; electric field gradient; Hf solute clusters; helium-vacancy complex; defect recovery. 1. Introduction. In recent years a considerable effort has been directed to the behaviour of helium in metals as helium is produced by (n, α) reaction in nuclear materials. Helium atoms are insoluble in metals and are strongly attracted ...

  10. 21 CFR 868.1640 - Helium gas analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Helium gas analyzer. 868.1640 Section 868.1640...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1640 Helium gas analyzer. (a) Identification. A helium gas analyzer is a device intended to measure the concentration of helium in a gas...

  11. Positron and deuteron depth profiling in helium-3-implanted electrum-like alloy

    Science.gov (United States)

    Grynszpan, R. I.; Baclet, N.; Darque, A.; Flament, J. L.; Zielinski, F.; Anwand, W.; Brauer, G.

    2006-02-01

    In spite of previous extensive studies, the helium behavior in metals still remains an issue in microelectronics as well as in nuclear technology. A gold-silver solid solution (Au 60Ag 40: synthetic gold-rich electrum) was chosen as a relevant model to study helium irradiation of heavy metals. After helium-3 ion implantation at an energy ranging from 4.2 to 5.6 MeV, nuclear reaction analysis (NRA) based on the 3He(d,p) 4He reaction, was performed in order to study the thermal diffusion of helium atoms. At room temperature, NRA data reveal that a single Gaussian can fit the He-distribution, which remains unchanged after annealing at temperatures below 0.45 of the melting point. Slow positron implantation spectroscopy, used to monitor the fluence dependence of induced defects unveils a positron saturation trapping, which occurs for He contents of the order of 50-100 appm, whereas concentrations larger than 500 appm seem to favor an increase in the S-parameter of Doppler broadening. Moreover, at high temperature, NRA results clearly show that helium long range diffusion occurs, though, without following a simple Fick law.

  12. Helium release and microstructural changes in Er(D,T)2-x3Hex films).

    Energy Technology Data Exchange (ETDEWEB)

    Gelles, D. S. (Pacific Northwest National Laboratory, Richland, WA); Browning, James Frederick; Snow, Clark Sheldon; Banks, James Clifford; Mangan, Michael A.; Rodriguez, Mark Andrew; Brewer, Luke N.; Kotula, Paul Gabriel

    2007-12-01

    Er(D,T){sub 2-x} {sup 3}He{sub x}, erbium di-tritide, films of thicknesses 500 nm, 400 nm, 300 nm, 200 nm, and 100 nm were grown and analyzed by Transmission Electron Microscopy, X-Ray Diffraction, and Ion Beam Analysis to determine variations in film microstructure as a function of film thickness and age, due to the time-dependent build-up of {sup 3}He in the film from the radioactive decay of tritium. Several interesting features were observed: One, the amount of helium released as a function of film thickness is relatively constant. This suggests that the helium is being released only from the near surface region and that the helium is not diffusing to the surface from the bulk of the film. Two, lenticular helium bubbles are observed as a result of the radioactive decay of tritium into {sup 3}He. These bubbles grow along the [111] crystallographic direction. Three, a helium bubble free zone, or 'denuded zone' is observed near the surface. The size of this region is independent of film thickness. Four, an analysis of secondary diffraction spots in the Transmission Electron Microscopy study indicate that small erbium oxide precipitates, 5-10 nm in size, exist throughout the film. Further, all of the films had large erbium oxide inclusions, in many cases these inclusions span the depth of the film.

  13. Development of a transferline connecting a helium liquefier coldbox and a liquid helium Dewar

    Science.gov (United States)

    Menon, Rajendran S.; Rane, Tejas; Chakravarty, Anindya; Joemon, V.

    2017-02-01

    A helium liquefier with demonstrated capacity of 32 1/hr has been developed by BARC. Mumbai. A transferline for two way flow of helium between the helium liquefier coldbox and receiver Dewar has been developed in-house at BARC. Further, a functionally similar, but structurally improved transferline has been developed through a local fabricator. This paper describes and discusses issues related to the development of these cryogenic transferlines. The developed transferlines have been tested with a flow of liquid nitrogen and successfully utilised later in the helium liquefier plant.

  14. ASACUSA Anti-protonic Helium_Final

    CERN Multimedia

    CERN Audiovisual Production Service; CERN AD; Paola Catapano; Julien Ordan, Arzur Catel; Paola Catapano; ASACUSA COLLABORATION

    2016-01-01

    Latest precision measurement of the mass of the proton and the anti proton though the production of antiprotonic helium by the ASACUSA experiment at CERN's antimatter factory, with a beam from the Antiproton Decelerator

  15. Realization of mechanical rotation in superfluid helium

    Science.gov (United States)

    Gordon, E. B.; Kulish, M. I.; Karabulin, A. V.; Matyushenko, V. I.; Dyatlova, E. V.; Gordienko, A. S.; Stepanov, M. E.

    2017-09-01

    The possibility of using miniaturized low-power electric motors submerged in superfluid helium for organization of rotation inside a cryostat has been investigated. It has been revealed that many of commercial micromotors can operate in liquid helium consuming low power. Turret with 5 sample holders, assembled on the base of stepper motor, has been successfully tested in experiments on the nanowire production in quantized vortices of superfluid helium. Application of the stepper motor made it possible in a single experiment to study the effect of various experimental parameters on the yield and quality of the nanowires. The promises for continuous fast rotation of the bath filled by superfluid helium by using high-speed brushless micromotor were outlined and tested. Being realized, this approach will open new possibility to study the guest particles interaction with the array of parallel linear vortices in He II.

  16. Helium-Hydrogen Recovery System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Immense quantities of expensive liquefied helium are required at Stennis and Kennedy Space Centers for pre-cooling rocket engine propellant systems prior to filling...

  17. Helium bubble formation in ultrafine and nanocrystalline tungsten under different extreme conditions

    Science.gov (United States)

    El-Atwani, O.; Hattar, K.; Hinks, J. A.; Greaves, G.; Harilal, S. S.; Hassanein, A.

    2015-03-01

    We have investigated the effects of helium ion irradiation energy and sample temperature on the performance of grain boundaries as helium sinks in ultrafine grained and nanocrystalline tungsten. Irradiations were performed at displacement and non-displacement energies and at temperatures above and below that required for vacancy migration. Microstructural investigations were performed using Transmission Electron Microscopy (TEM) combined with either in-situ or ex-situ ion irradiation. Under helium irradiation at an energy which does not cause atomic displacements in tungsten (70 eV), regardless of temperature and thus vacancy migration conditions, bubbles were uniformly distributed with no preferential bubble formation on grain boundaries. At energies that can cause displacements, bubbles were observed to be preferentially formed on the grain boundaries only at high temperatures where vacancy migration occurs. Under these conditions, the decoration of grain boundaries with large facetted bubbles occurred on nanocrystalline grains with dimensions less than 60 nm. We discuss the importance of vacancy supply and the formation and migration of radiation-induced defects on the performance of grain boundaries as helium sinks and the resulting irradiation tolerance of ultrafine grained and nanocrystalline tungsten to bubble formation.

  18. Helium and Neon in Comets

    Science.gov (United States)

    Jewitt, David

    1996-01-01

    Two comets were observed with EUVE in late 1994. Both comet Mueller and comet Borrelly are short-period comets having well established orbital elements and accurate ephemerides. Spectra of 40 ksec were taken of each. No evidence for emission lines from either Helium or Neon was detected. We calculated limits on the production rates of these atoms (relative to solar) assuming a standard isotropic outflow model, with a gas streaming speed of 1 km/s. The 3-sigma (99.7% confidence) limits (1/100,000 for He, 0.8 for Ne) are based on a conservative estimate of the noise in the EUVE spectra. They are also weakly dependent on the precise pointing and tracking of the EUVE field of view relative to the comet during the integrations. These limits are consistent with ice formation temperatures T greater than or equal to 30 K, as judged from the gas trapping experiments of Bar-Nun. For comparison, the solar abundances of these elements are He/O = 110, Ne/O = 1/16. Neither limit was as constraining as we had initially hoped, mainly because comets Mueller and Borrelly were intrinsically less active than anticipated.

  19. Helium Detonations on Neutron Stars

    Science.gov (United States)

    Zingale, M.; Timmes, F. X.; Fryxell, B.; Lamb, D. Q.; Olson, K.; Calder, A. C.; Dursi, L. J.; Ricker, P.; Rosner, R.; MacNeice, P.; Tufo, H. M.

    2001-03-01

    We present the results of a numerical study of helium detonations on the surfaces of neutron stars. We describe two-dimensional simulations of the evolution of a detonation as it breaks through the accreted envelope of the neutron star and propagates laterally through the accreted material. The detonation front propagates laterally at nearly the Chapman-Jouguet velocity, v=1.3×109 cm s-1. A series of surface waves propagate across the pool of hot ash behind the detonation front with the same speed, matching the speed expected from shallow water wave theory. The entire envelope oscillates in the gravitational potential well of the neutron star with a period of ~50 μs. The photosphere reaches an estimated height of 10 km above the surface of the neutron star. Our study confirms that such a detonation can insure the spread of burning over the entire neutron star surface on a timescale consistent with burst rise times. We analyze the sensitivity of the results to the spatial resolution and the assumed initial conditions. We conclude by presenting a comparison of this model to type I X-ray bursts.

  20. Heavy ion therapy: Bevalac epoch

    Energy Technology Data Exchange (ETDEWEB)

    Castro, J.R.

    1993-10-01

    An overview of heavy ion therapy at the Bevelac complex (SuperHILac linear accelerator + Bevatron) is given. Treatment planning, clinical results with helium ions on the skull base and uveal melanoma, clinical results with high-LET charged particles, neon radiotherapy of prostate cancer, heavy charged particle irradiation for unfavorable soft tissue sarcoma, preliminary results in heavy charged particle irradiation of bone sarcoma, and irradiation of bile duct carcinoma with charged particles and-or photons are all covered. (GHH)

  1. Doubly excited helium. From strong correlation to chaos

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yuhai

    2006-03-15

    In the present dissertation, the double excitation states of helium including the autoionization decay of these states were studied experimentally and theoretically in a broad energy region, which includes the transition from strong correlation below the low single ionization thresholds (SIT) to the region of quantum chaos at energies very close to the double-ionization threshold. Two kind of experiments were performed, namely total-ion-yield measurements with the aim to observe total cross sections (TCS) and electron time-of-flight (TOF) measurements to obtain partial cross sections (PCS) as well as angular distribution parameters (ADP). Both types of measurements were performed at the third generation synchrotron radiation facility BESSY II in Berlin. The TCSs were recorded up to the SIT I{sub 15}, and they were found to be in in excellent agreement with state-of-the-art complex-rotation calculations performed recently by D. Delande. These experimental and theoretical data on the TCSs were analyzed in order to study quantum chaos in doubly excited helium, and interesting signatures of quantum chaos were found. The TOF technique allowed to measure PCSs and ADPs in the energy regions from I{sub 5} to I{sub 9} and I{sub 7}, respectively. These experimental data provide a critical assessment of theoretical models that can be used to explore the dynamics of strong correlation as well as quantum chaos in helium. In the theoretical part of this dissertation, the n- and l-specific PCSs and ADPs below I{sub 4} were calculated employing the R-matrix method. The present theoretical results agree well with a recent experimental study of l-specific PCSs below I{sub 4} by J.R. Harries et al. An analysis of patterns in the PCSs and ADPs on the basis of the present experimental and theoretical l-specific data allowed to improve the present understanding of autoionization decay dynamics in this two-electron atom. (orig.)

  2. Effects of helium implantation on fatigue properties of F82H-IEA heat

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, N.; Murase, Y.; Nagakawa, J. [National Research Institute for Metals, Tsukuba, Ibaraki (Japan)

    2007-07-01

    Full text of publication follows: Ferritic steels including reduced activation ones that have been recognized as attractive structural candidates for DEMO reactors and the beyond are known to be highly resistant to helium embrittlement. However, almost studies that deduced this behavior have been carried out by means of short time experiments such as tensile tests, and a few results are available concerning long term inspections, although the detrimental helium effect appears more severely in the latter. The aim of this work is to obtain further information on the influence of helium on fatigue properties of a representative reduced activation ferritic/martensitic steel F82H (8Cr2WVTa) using helium implantation technique with a cyclotron. The material examined is an IEA heat version of F82H. In order to realize a fine grain size due to thin specimens (0.08 mm thick) for ion irradiation, normalizing was conducted at rather low temperature of 1213 K, followed by tempering at 1023 K. Helium was implanted by {alpha}-particle irradiation at 823 K, a desired highest temperature of this material for first wall application, to the concentration of 100 appm He with an implantation rate of about 1.7 x 10{sup -3} appm He/s. Subsequent fatigue tests were conducted at the same temperature as that of irradiation, not only on implanted specimens but also on reference controls which were not implanted with helium but experienced the same metallurgical histories as those of irradiated ones. After fracture, samples were observed with electron microscopes. In short time periods, it has been notified that helium introduction caused no significant deterioration of both fatigue life and extension at fracture. In addition, all specimens failed in a fully trans-crystalline and ductile manner, irrespective of whether helium was present or not. Indication of grain boundary embrittlement was therefore not discerned. These facts would reflect insusceptible characteristics of this material to

  3. Influence of displacement damage on deuterium and helium retention in austenitic and ferritic-martensitic alloys considered for ADS service

    Energy Technology Data Exchange (ETDEWEB)

    Voyevodin, V.N.; Karpov, S.A.; Kopanets, I.E.; Ruzhytskyi, V.V. [National Science Center “Kharkov Institute of Physics and Technology” Kharkov, 1, Akademicheskaya St., Kharkov, 61108 (Ukraine); Tolstolutskaya, G.D., E-mail: g.d.t@kipt.kharkov.ua [National Science Center “Kharkov Institute of Physics and Technology” Kharkov, 1, Akademicheskaya St., Kharkov, 61108 (Ukraine); Garner, F.A. [Radiation Effects Consulting, Richland, WA (United States)

    2016-01-15

    The behavior of ion-implanted hydrogen (deuterium) and helium in austenitic 18Cr10NiTi stainless steel, EI-852 ferritic steel and ferritic/martensitic steel EP-450 and their interaction with displacement damage were investigated. Energetic argon irradiation was used to produce displacement damage and bubble formation to simulate nuclear power environments. The influence of damage morphology and the features of radiation-induced defects on deuterium and helium trapping in structural alloys was studied using ion implantation, the nuclear reaction D({sup 3}He,p){sup 4}He, thermal desorption spectrometry and transmission electron microscopy. It was found in the case of helium irradiation that various kinds of helium-radiation defect complexes are formed in the implanted layer that lead to a more complicated spectra of thermal desorption. Additional small changes in the helium spectra after irradiation with argon ions to a dose of ≤25 dpa show that the binding energy of helium with these traps is weakly dependent on the displacement damage. It was established that retention of deuterium in ferritic and ferritic-martensitic alloys is three times less than in austenitic steel at damage of ∼1 dpa. The retention of deuterium in steels is strongly enhanced by presence of radiation damages created by argon ion irradiation, with a shift in the hydrogen release temperature interval of 200 K to higher temperature. At elevated temperatures of irradiation the efficiency of deuterium trapping is reduced by two orders of magnitude.

  4. Fire-resisting painting. Qualification and application of insulating coatings of cables; Farbe kontra Feuer. Qualifizierung und Anwendung von daemmschichtbildenden Beschichtungen auf Kabelanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Will, J.; Hosser, D. [Technische Univ. Braunschweig (Germany). Inst. fuer Baustoffe, Massivbau und Brandschutz

    1999-11-01

    Extensive investigations of coated and uncoated PVC cables showed a qualitative and quantitative effect of coatings in terms of fire protection. The method employed is suited as a qualifaication method which is compared with accepted test methods for low-inflammable constructional materials (DIN 4102-1) or electric cables with improved fire resistance (DIN VDE 0472-804). Cables and cable coatings meeting the requirements of the qualification method have a higher safety level and thus a wider range of applications. With this in mind, the authors discuss a new version of the standard for cable systems with a view to fire-resistant coatings. [German] In umfangreichen Untersuchungen an unbeschichteten und beschichteten PVC-Kabeln konnte eine erhebliche Reduzierung der Brandrisiken durch Anwendung von Daemmschichtbildern als Kabelschutzsystem qualitativ und quantitativ nachgewiesen werden. Die dabei angewandte Vorgehensweise eignet sich als Qualifizierungsverfahren, das mit anerkannten Pruefverfahren fuer schwerentflammbare Baustoffe (DIN 4102-1) oder elektrische Kabel mit verbessertem Brandverhalten (DIN VDE 0472-804) verglichen wird. Aufgrund des Vergleichs der Pruefverfahren, aber auch des Brandverhaltens von beschichteten Kabeln bei den unterschiedlichen Untersuchungsbedingungen ergibt sich ein hoeheres Sicherheitsniveau und damit zusaetzliche Anwendungsgebiete fuer elektrische Kabel und Kabelbeschichtungen, die die Kriterien des Qualifizierungsverfahrens erfuellen. Unter diesem Gesichtspunkt wird die neue Fassung der Musterrichtlinie fuer Leitungsanlagen in Bezug auf die Anwendung von Brandschutzbeschichtungen auf Kabeln diskutiert. (orig.)

  5. Hydrogen isotope accumulation in the helium implantation zone in tungsten

    Science.gov (United States)

    Markelj, S.; Schwarz-Selinger, T.; Založnik, A.

    2017-06-01

    The influence of helium (He) on deuterium (D) transport and retention was studied experimentally in tungsten (W). Helium was implanted 1 µm deep into W to a maximum calculated concentration of 3.4 at.%. To minimize the influence of displacement damage created during the He implantation on D retention, so-called self-damaged W was used. W was damaged by 20 MeV W ion bombardment and defects were populated by low-temperature D plasma at room temperature before He implantation. Deuterium depth profiling was performed in situ during isochronal annealing in the temperature range from 300 K to 800 K. It is shown for the first time unambiguously that He attracts D and locally increases D trapping. Deuterium retention increased by a factor of two as compared to a non-He implanted W reference after sample annealing at 450 K. Rate equation modelling can explain the measured D depth profiles quantitatively when keeping the de-trapping parameters unchanged but only increasing the number of traps in the He zone. This bolsters the confidence in the theoretical calculations predicting that more hydrogen isotopes can be stored around a He cluster zone.

  6. Partial cross sections of helium satellites at medium photon energies

    Energy Technology Data Exchange (ETDEWEB)

    Wehlitz, R.; Sellin, I.A. [Univ. of Tennessee, Knoxville, TN (United States); Hemmers, O. [Univ. of Nevada, Las Vegas, NV (United States)] [and others

    1997-04-01

    Still of current interest is the important role of single ionization with excitation compared to single ionization alone. The coupling between the electrons and the incoming photon is a single-particle operator. Thus, an excitation in addition to an ionization, leading to a so-called satellite line in a photoelectron spectrum, is entirely due to electron-electron interaction and probes the electron correlation in the ground and final state. Therefore the authors have undertaken the study of the intensity of helium satellites He{sup +}nl (n = 2 - 6) relative to the main photoline (n = 1) as a function of photon energy at photon energies well above threshold up to 900 eV. From these results they could calculate the partial cross-sections of the helium satellites. In order to test the consistency of their satellite-to-1s ratios with published double-to-single photoionization ratios, the authors calculated the double-to-single photoionization ratio from their measured ratios using the theoretical energy-distribution curves of Chang and Poe and Le Rouzo and Dal Cappello which proved to be valid for photon energies below 120 eV. These calculated double-to-single ionization ratios agree fairly well with recent ion measurements. In the lower photon energy range the authors ratios agree better with the ratios of Doerner et al. while for higher photon energies the agreement is better with the values of Levin et al.

  7. Helium ion beam induced growth of hammerhead AFM probes

    NARCIS (Netherlands)

    Nanda, G.; Van Veldhoven, E.; Maas, D.; Sadeghian, H.; Alkemade, P.F.A.

    2015-01-01

    The authors report the direct-write growth of hammerhead atomic force microscope(AFM) probes by He+beam induced deposition of platinum-carbon. In order to grow a thin nanoneedle on top of a conventional AFM probe, the authors move a focused He+beam during exposure to a PtC precursor gas. In the

  8. Stopping Power of Solid Argon for Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Grauersen, O.

    1981-01-01

    studied. This proves that the gas/solid difference for argon predicted in recent stopping-power tabulations is significantly overestimated. With high-order Z1 correction terms included in the theoretical description, calculated shell corrections based on the Lindhard-Scharff model are in good agreement...

  9. Helium ion beam induced growth of hammerhead AFM probes

    NARCIS (Netherlands)

    Nanda, G.; Veldhoven, E. van; Maas, D.J.; Sadeghian Marnani, H.; Alkemade, P.F.A.

    2015-01-01

    The authors report the direct-write growth of hammerhead atomic force microscope (AFM) probes by He+ beam induced deposition of platinum-carbon. In order to grow a thin nanoneedle on top of a conventional AFM probe, the authors move a focused He+ beam during exposure to a PtC precursor gas. In the

  10. Suicide by asphyxiation due to helium inhalation.

    Science.gov (United States)

    Howard, Matthew O; Hall, Martin T; Edwards, Jeffrey D; Vaughn, Michael G; Perron, Brian E; Winecker, Ruth E

    2011-03-01

    Suicide by asphyxiation using helium is the most widely-promoted method of "self-deliverance" by right-to-die advocates. However, little is known about persons committing such suicides or the circumstances and manner in which they are completed. Prior reports of suicides by asphyxiation involving helium were reviewed and deaths determined by the North Carolina Office of the Chief Medical Examiner to be helium-associated asphyxial suicides occurring between January 1, 2000 and December 31, 2008 were included in a new case series examined in this article. The 10 asphyxial suicides involving helium identified in North Carolina tended to occur almost exclusively in non-Hispanic, white men who were relatively young (M age = 41.1 T 11.6). In 6 of 10 cases, decedents suffered from significant psychiatric dysfunction; in 3 of these 6 cases, psychiatric disorders were present comorbidly with substance abuse. In none of these cases were decedents suffering from terminal illness. Most persons committing suicide with helium were free of terminal illness but suffered from psychiatric and/or substance use disorders.

  11. Helium release from radioisotope heat sources

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, D.E.; Early, J.W.; Starzynski, J.S.; Land, C.C.

    1984-05-01

    Diffusion of helium in /sup 238/PuO/sub 2/ fuel was characterized as a function of the heating rate and the fuel microstructure. The samples were thermally ramped in an induction furnace and the helium release rates measured with an automated mass spectrometer. The diffusion constants and activation energies were obtained from the data using a simple diffusion model. The release rates of helium were correlated with the fuel microstructure by metallographic examination of fuel samples. The release mechanism consists of four regimes, which are dependent upon the temperature. Initially, the release is controlled by movement of point defects combined with trapping along grain boundaries. This regime is followed by a process dominated by formation and growth of helium bubbles along grain boundaries. The third regime involves volume diffusion controlled by movement of oxygen vacancies. Finally, the release at the highest temperatures follows the diffusion rate of intragranular bubbles. The tendency for helium to be trapped within the grain boundaries diminishes with small grain sizes, slow thermal pulses, and older fuel.

  12. Commissioning of a new helium pipeline

    Science.gov (United States)

    2000-01-01

    At the commissioning of a new high-pressure helium pipeline at Kennedy Space Center, participants cut the lines to helium-filled balloons. From left, they are Center Director Roy Bridges; Michael Butchko, president, SGS; Pierre Dufour, president and CEO, Air Liquide America Corporation; David Herst, director, Delta IV Launch Sites; Pamela Gillespie, executive administrator, office of Congressman Dave Weldon; and Col. Samuel Dick, representative of the 45th Space Wing. The nine-mile-long buried pipeline will service launch needs at the new Delta IV Complex 37 at Cape Canaveral Air Force Station. It will also serve as a backup helium resource for Shuttle launches. Nearly one launch's worth of helium will be available in the pipeline to support a Shuttle pad in an emergency. The line originates at the Helium Facility on KSC and terminates in a meter station at the perimeter of the Delta IV launch pad. Others at the ceremony were Jerry Jorgensen, pipeline project manager, Space Gateway Support (SGS), and Ramon Lugo, acting executive director, JPMO.

  13. SIMS as a new methodology to depth profile helium in as-implanted and annealed pure bcc metals?

    Energy Technology Data Exchange (ETDEWEB)

    Gorondy-Novak, S. [CEA, DEN, Service de Recherches de Métallurgie Physique, Université Paris-Saclay, F-91191 Gif-sur-Yvette (France); Jomard, F. [Groupe d' Etude de la Matière Condensée, CNRS, UVSQ, 45 avenue des Etats-Unis, 78035 Versailles cedex (France); Prima, F. [PSL Research University, Chimie ParisTech – CNRS, Institut de Recherche de Chimie Paris, 75005 Paris (France); Lefaix-Jeuland, H., E-mail: helene.lefaix@cea.fr [CEA, DEN, Service de Recherches de Métallurgie Physique, Université Paris-Saclay, F-91191 Gif-sur-Yvette (France)

    2017-05-01

    Reliable He profiles are highly desirable for better understanding helium behavior in materials for future nuclear applications. Recently, Secondary Ions Mass Spectrometry (SIMS) allowed the characterization of helium distribution in as-implanted metallic systems. The Cs{sup +} primary ion beam coupled with CsHe{sup +} molecular detector appeared to be a promising technique which overcomes the very high He ionization potential. In this study, {sup 4}He depth profiles in pure body centered cubic (bcc) metals (V, Fe, Ta, Nb and Mo) as-implanted and annealed, were obtained by SIMS. All as-implanted samples exhibited a projected range of around 200 nm, in agreement with SRIM theoretical calculations. After annealing treatment, SIMS measurements evidenced the evolution of helium depth profile with temperature. The latter SIMS results were compared to the helium bubble distribution obtained by Transmission Electron Microscopy (TEM). This study confirmed the great potential of this experimental procedure as a He-depth profiling technique in bcc metals. Indeed, the methodology described in this work could be extended to other materials including metallic and non-metallic compounds. Nevertheless, the quantification of helium concentration after annealing treatment by SIMS remains uncertain probably due to the non-uniform ionization efficiency in samples containing large bubbles.

  14. Ignition and afterglow dynamics of a high pressure nanosecond pulsed helium micro-discharge: II. Rydberg molecules kinetics

    Science.gov (United States)

    Carbone, Emile A. D.; Schregel, Christian-Georg; Czarnetzki, Uwe

    2016-10-01

    In this paper, we discuss the experimental results presented in Schregel et al (2016 Plasma Sources Sci. Technol. 25 054003) on a high pressure micro-discharge operated in helium and driven by nanosecond voltage pulses. A simple global plasma chemistry model is developed to describe the ions, excited atomic and molecular species dynamics in the ignition and early afterglow regimes. The existing experimental data on high pressure helium kinetics is reviewed and critically discussed. It is highlighted that several inconsistencies in the branching ratio of neutral assisted associative and dissociative processes currently exist in the literature and need further clarification. The model allows to pinpoint the mechanisms responsible for the large amounts of Rydberg molecules produced in the discharge and for the helium triplet metastable state in the afterglow. The main losses of electrons are also identified. The fast quenching of excited He (n  >  3) states appears to be a significant source of Rydberg molecules which has been previously neglected. The plasma model finally draws a simplified, but still accurate description of high pressure helium discharges based on available experimental data for ion and neutral helium species.

  15. Krypton and helium irradiation damage in neodymium-zirconolite

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, M., E-mail: m.gilbert@imperial.ac.uk [Centre for Advanced Structural Ceramics, Department of Materials, Imperial College London, Exhibition Road, London SW7 2AZ (United Kingdom); Davoisne, C. [Laboratoire de Reactivite et Chimie des Solides, CNRS-UMR 6007, Universite de Picardie Jules Verne, 33 rue Saint-Leu, 80039 Amiens (France); Stennett, M.; Hyatt, N. [Immobilisation Science Laboratory, University of Sheffield, Sir Robert Hadfield Building, Mappin Street, Sheffield S1 3JD (United Kingdom); Peng, N.; Jeynes, C. [Surrey Ion Beam Centre, Nodus Laboratory, University of Surrey, Guildford, GU2 7XH Surrey (United Kingdom); Lee, W.E. [Centre for Advanced Structural Ceramics, Department of Materials, Imperial College London, Exhibition Road, London SW7 2AZ (United Kingdom)

    2011-09-01

    A leading candidate for the immobilisation of actinides, zirconolite's suitability as a potential ceramic host for plutonium disposition, both in storage and geological disposal, has been the subject of much research. One key aim of this study is to understand the effects of radiation damage and noble gas accommodation within the zirconolite material. To this end, a series of ex situ irradiations have been performed on polycrystalline (Ca{sub 0.8}Nd{sub 0.2})Zr(Ti{sub 1.8}Al{sub 0.2})O{sub 7} zirconolite samples. Zirconolite samples, doped with Nd{sup 3+} (as a Pu surrogate) on the Ca-site and charge-balanced by substituting Al{sup 3+} onto the Ti-site, were irradiated with {sup 36}Kr{sup +} (2 MeV) ions at fluences of 1 x 10{sup 14} and 5 x 10{sup 15} cm{sup -2} and {sup 4}He{sup +} (200 keV) ions at fluences of 1 x 10{sup 14}, 5 x 10{sup 15} and 1 x 10{sup 17} cm{sup -2} to simulate the impact of alpha decay on the microstructure. Microstructural analysis revealed no damage present at the lower Kr{sup +} fluence, but that the higher {sup 36}Kr{sup +} fluence rendered the zirconolite completely amorphous. Similarly, evidence of helium accumulation was only seen at the highest {sup 4}He{sup +} fluence (1 x 10{sup 17} cm{sup -2}). Monte Carlo simulations using the TRIM code predict the highest concentration of helium accumulating at a depth of 720 nm, in good agreement with the experimental observations.

  16. Screw Compressor Characteristics for Helium Refrigeration Systems

    Science.gov (United States)

    Ganni, V.; Knudsen, P.; Creel, J.; Arenius, D.; Casagrande, F.; Howell, M.

    2008-03-01

    The oil injected screw compressors have practically replaced all other types of compressors in modern helium refrigeration systems due to their large displacement capacity, minimal vibration, reliability and capability of handling helium's high heat of compression. At the present state of compressor system designs for helium systems, typically two-thirds of the lost input power is due to the compression system. Therefore it is important to understand the isothermal and volumetric efficiencies of these machines to help properly design these compression systems to match the refrigeration process. This presentation summarizes separate tests that have been conducted on Sullair compressors at the Superconducting Super-Collider Laboratory (SSCL) in 1993, Howden compressors at Jefferson Lab (JLab) in 2006 and Howden compressors at the Spallation Neutron Source (SNS) in 2006. This work is part of an ongoing study at JLab to understand the theoretical basis for these efficiencies and their loss mechanisms, as well as to implement practical solutions.

  17. Feasibility of lunar Helium-3 mining

    Science.gov (United States)

    Kleinschneider, Andreas; Van Overstraeten, Dmitry; Van der Reijnst, Roy; Van Hoorn, Niels; Lamers, Marvin; Hubert, Laurent; Dijk, Bert; Blangé, Joey; Hogeveen, Joel; De Boer, Lennaert; Noomen, Ron

    With fossil fuels running out and global energy demand increasing, the need for alternative energy sources is apparent. Nuclear fusion using Helium-3 may be a solution. Helium-3 is a rare isotope on Earth, but it is abundant on the Moon. Throughout the space community lunar Helium-3 is often cited as a major reason to return to the Moon. Despite the potential of lunar Helium-3 mining, little research has been conducted on a full end-to-end mission. This abstract presents the results of a feasibility study conducted by students from Delft University of Technology. The goal of the study was to assess whether a continuous end-to-end mission to mine Helium-3 on the Moon and return it to Earth is a viable option for the future energy market. The set requirements for the representative end-to-end mission were to provide 10% of the global energy demand in the year 2040. The mission elements have been selected with multiple trade-offs among both conservative and novel concepts. A mission architecture with multiple decoupled elements for each transportation segment (LEO, transfer, lunar surface) was found to be the best option. It was found that the most critical element is the lunar mining operation itself. To supply 10% of the global energy demand in 2040, 200 tons of Helium-3 would be required per year. The resulting regolith mining rate would be 630 tons per second, based on an optimistic concentration of 20 ppb Helium-3 in lunar regolith. Between 1,700 to 2,000 Helium-3 mining vehicles would be required, if using University of Wisconsin’s Mark III miner. The required heating power, if mining both day and night, would add up to 39 GW. The resulting power system mass for the lunar operations would be in the order of 60,000 to 200,000 tons. A fleet of three lunar ascent/descent vehicles and 22 continuous-thrust vehicles for orbit transfer would be required. The costs of the mission elements have been spread out over expected lifetimes. The resulting profits from Helium

  18. Electron correlation for helium-like atoms

    Energy Technology Data Exchange (ETDEWEB)

    Roy, U. [Visvabharati Univ., Santiniketan (India). Dept. of Comput. Sci.; Talukdar, B. [Visvabharati Univ., Santiniketan (India). Dept. of Physics

    1999-02-01

    A recently proposed analytical approach to the ground-state energy of helium atom is generalised to study the effect of electron-electron correlation on the properties of helium isoelectronic sequence. The expectation values of the Hamiltonian and some important functions of radial distances are expressed in terms of derivatives of Lewis integrals which not only permit the straightforward variational calculation to get numerical results but also help one derive interesting recurrence relations for radial expectation values. The results presented for atoms from H{sup -} to Si{sup 12+} indicate that the present analytical model will have quantitative applicability for the study of electronic correlation in high-Z helium-like atoms within the framework of non-relativistic quantum mechanics. (orig.) 22 refs.

  19. Superfluid helium-4 in one dimensional channel

    Science.gov (United States)

    Kim, Duk Y.; Banavar, Samhita; Chan, Moses H. W.; Hayes, John; Sazio, Pier

    2013-03-01

    Superfluidity, as superconductivity, cannot exist in a strict one-dimensional system. However, the experiments employing porous media showed that superfluid helium can flow through the pores of nanometer size. Here we report a study of the flow of liquid helium through a single hollow glass fiber of 4 cm in length with an open id of 150 nm between 1.6 and 2.3 K. We found the superfluid transition temperature was suppressed in the hollow cylinder and that there is no flow above the transition. Critical velocity at temperature below the transition temperature was determined. Our results bear some similarity to that found by Savard et. al. studying the flow of helium through a nanohole in a silicon nitrite membrane. Experimental study at Penn State is supported by NSF Grants No. DMR 1103159.

  20. Experimental helium liquefier with a GM cryocooler

    Science.gov (United States)

    Choudhury, Anup; Sahu, Santosh

    2017-06-01

    A helium liquefier has been developed with a Gifford-McMahon cryocooler using the cold enthalpy available at the first stage, the inter-stage, and the second stage of the cryocooler. Most of the enthalpy of the helium gas at 300 K is absorbed in the first stage by a coaxial heat exchanger and inter-stage region of the cryocooler. Pre-cooled helium gas is liquefied at the second stage heat exchanger where the final cooldown and condensation happens. The measured production capacity of the liquefier is 17.4 l/day at atmospheric pressure. The whole setup has been designed to work in a coaxial configuration where the two heat exchangers, the cryostat, and the dewar are symmetrically placed around the central axis.

  1. The prospects of a subnanometer focused neon ion beam.

    Science.gov (United States)

    Rahman, F H M; McVey, Shawn; Farkas, Louis; Notte, John A; Tan, Shida; Livengood, Richard H

    2012-01-01

    The success of the helium ion microscope has encouraged extensions of this technology to produce beams of other ion species. A review of the various candidate ion beams and their technical prospects suggest that a neon beam might be the most readily achieved. Such a neon beam would provide a sputtering yield that exceeds helium by an order of magnitude while still offering a theoretical probe size less than 1-nm. This article outlines the motivation for a neon gas field ion source, the expected performance through simulations, and provides an update of our experimental progress. © Wiley Periodicals, Inc.

  2. On the size and structure of helium snowballs formed around charged atoms and clusters of noble gases.

    Science.gov (United States)

    Bartl, Peter; Leidlmair, Christian; Denifl, Stephan; Scheier, Paul; Echt, Olof

    2014-09-18

    Helium nanodroplets doped with argon, krypton, or xenon are ionized by electrons and analyzed in a mass spectrometer. HenNgx(+) ions containing up to seven noble gas (Ng) atoms and dozens of helium atoms are identified; the high resolution of the mass spectrometer combined with advanced data analysis make it possible to unscramble contributions from isotopologues that have the same nominal mass but different numbers of helium or Ng atoms, such as the magic He20(84)Kr2(+) and the isobaric, nonmagic He41(84)Kr(+). Anomalies in these ion abundances reveal particularly stable ions; several intriguing patterns emerge. Perhaps most astounding are the results for HenAr(+), which show evidence for three distinct, solid-like solvation shells containing 12, 20, and 12 helium atoms. This observation runs counter to the common notion that only the first solvation shell is solid-like but agrees with calculations by Galli et al. for HenNa(+) [J. Phys. Chem. A 2011, 115, 7300] that reveal three shells of icosahedral symmetry. HenArx(+) (2 ≤ x ≤ 7) ions appear to be especially stable if they contain a total of n + x = 19 atoms. A sequence of anomalies in the abundance distribution of HenKrx(+) suggests that rings of six helium atoms are inserted into the solvation shell each time a krypton atom is added to the ionic core, from Kr(+) to Kr3(+). Previously reported strong anomalies at He12Kr2(+) and He12Kr3(+) [Kim , J. H.; et al. J. Chem. Phys. 2006, 124, 214301] are attributed to a contamination. Only minor local anomalies appear in the distributions of HenXex(+) (x ≤ 3). The distributions of HenKr(+) and HenXe(+) show strikingly similar, broad features that are absent from the distribution of HenAr(+); differences are tentatively ascribed to the very different fragmentation dynamics of these ions.

  3. Microstructure of HIPed and SPSed 9Cr-ODS steel and its effect on helium bubble formation

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Chenyang [Key Laboratory for Anisotropy and Texture of Materials (Ministry of Education), School of Material Science and Engineering, Northeastern University, Shenyang 110819, Liaoning (China); Department of Nuclear Engineering and Radiological Science, University of Michigan, Ann Arbor, MI, 48109 (United States); Lu, Zheng, E-mail: luz@atm.neu.edu.cn [Key Laboratory for Anisotropy and Texture of Materials (Ministry of Education), School of Material Science and Engineering, Northeastern University, Shenyang 110819, Liaoning (China); Xie, Rui; Liu, Chunming [Key Laboratory for Anisotropy and Texture of Materials (Ministry of Education), School of Material Science and Engineering, Northeastern University, Shenyang 110819, Liaoning (China); Wang, Lumin, E-mail: lmwang@umich.edu [Department of Nuclear Engineering and Radiological Science, University of Michigan, Ann Arbor, MI, 48109 (United States)

    2016-06-15

    Two 9Cr-ODS steels with the same nominal composition were consolidated by hot isostatic pressing (HIP, named COS-1) and spark plasma sintering (SPS, named COS-2). Helium ions were implanted into COS-1, COS-2 and non-ODS Eurofer 97 steels up at 673 K. Microstructures before and after helium ion implantations were carefully characterized. The results show a bimodal grain size distribution in COS-2 and a more uniform grain size distribution in COS-1. Nanoscale clusters of GP-zone type Y–Ti–O and Y{sub 2}Ti{sub 2}O{sub 7} pyrochlore as well as large spinel Mn(Ti)Cr{sub 2}O{sub 4} particles are all observed in the two ODS steels. The Y–Ti-enriched nano-oxides in COS-1 exhibit higher number density and smaller size than in COS-2. The Y–Ti-enriched nano-oxides in fine grains of COS-2 show higher number density and smaller size than that in coarse grains of COS-2. Nano-oxides effectively trap helium atoms and lead to the formation of high density and ultra-fine helium bubbles. - Highlights: • The microstructure changes of two ODS steels before and after helium ion implantation have been elucidated. • The mechanism of the microstructures of ODS steels under varied thermal mechanical processing paths have been explored. • The dependence of the size, density and distribution of helium bubbles on the specific microstructure features are explored.

  4. Temperature Rises In Pumps For Superfluid Helium

    Science.gov (United States)

    Kittel, Peter

    1990-01-01

    Report discusses increases in temperature of superfluid helium in centrifugal and fountain-effect pumps. Intended for use in transfers of superfluid helium in outer space. Increases in temperature significantly affect losses during transfers and are important in selection of temperatures of supply tanks. Purpose of study, increase in temperature in fountain-effect pump calculated on basis of thermodynamic considerations, starting from assumption of ideal pump. Results of recent tests of ceramic material intended for use in such pumps support this assumption. Overall, centrifugal pumps more effective because it produces smaller rise in temperature.

  5. Laser-induced thermotherapy (LITT). Application of round and sharp laser systems; Laserinduzierte interstitielle Thermotherapie (LITT). Anwendung und spitzer Laserapplikatorsysteme - erste Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Puls, R.; Stroszczynski, C.; Felix, R. [Virchow Klinikum Berlin (Germany). Strahlenklinik; Humboldt-Universitaet, Berlin (Germany). Inst. fuer Roentgendiagnostik; Hosten, N. [Greifswald Univ. (Germany). Inst. fuer Diagnostische Radiologie; Kreissig, R.; Gaffke, G. [Virchow Klinikum Berlin (Germany). Strahlenklinik

    2001-03-01

    Purpose: To assess the advantages and disadvantages by using round and sharp laser application systems during laser-induced thermotherapy. Method: 6 in vitro examinations were performed and 12 patients with liver metastases of colerectal carcinoma were treated with laser-induced thermotherapy. All lesions were closely localised to the diaphragm, liver capsule and large intrahepatic vessels. Five patients were treated with the sharp and 7 patients with the round applicator system. After CT-guided insertion of the catheter system into the metastasis laser therapy was performed under MRI control (approx. 25 M, 20 min). Results: Reduction of the distance between the laser applicator and rounded laser catheter tipp (approx. 0.5-1 cm) leads to better placement of the laser applicator in metastases located near the diaphragm, liver capsule and large intrahepatic vessels. Improved therapy results due to complete ablation of metastases were obtained. All patients treated with the round system had complete ablation of metastasis. In 3 of 5 patients treated with the sharp system, MRI control 2 days after therapy showed a residual tumour margin close to the diaphragm or to an intrahepatic vessel. Discussion: Improved ablation can be obtained by closer placement of a round laser catheter in liver metastasis located near the diaphragm, liver capsule and large intrahepatic vessels. (orig.) [German] Ziel: Erarbeitung der Vorteile und Nachteile bei Anwendung von runden und spitzen Laserapplikatorsystemen im Rahmen der laserinduzierten interstitiellen Thermotherapie. Material/Methode: Neben 6 In-vitro-Versuchen wurden 12 Patienten mit Lebermetastasen kolorektaler Karzinome mit Lokalisation unter dem Zwerchfell bzw. am Leberrand oder in der Naehe von grossen Lebergefaessen mit der laserinduzierten Thermotherapie (LITT) behandelt. 5 Patienten wurden mit spitzen, 7 Patienten mit runden Laser-Applikationssets behandelt. Nach CT-gesteuerter Punktion der Metastasen erfolgte die LITT unter

  6. Electron diffraction of CBr4 in superfluid helium droplets: A step towards single molecule diffraction

    Science.gov (United States)

    2016-01-01

    We demonstrate the practicality of electron diffraction of single molecules inside superfluid helium droplets using CBr4 as a testing case. By reducing the background from pure undoped droplets via multiple doping, with small corrections for dimers and trimers, clearly resolved diffraction rings of CBr4 similar to those of gas phase molecules can be observed. The experimental data from CBr4 doped droplets are in agreement with both theoretical calculations and with experimental results of gaseous species. The abundance of monomers and clusters in the droplet beam also qualitatively agrees with the Poisson statistics. Possible extensions of this approach to macromolecular ions will also be discussed. This result marks the first step in building a molecular goniometer using superfluid helium droplet cooling and field induced orientation. The superior cooling effect of helium droplets is ideal for field induced orientation, but the diffraction background from helium is a concern. This work addresses this background issue and identifies a possible solution. Accumulation of diffraction images only becomes meaningful when all images are produced from molecules oriented in the same direction, and hence a molecular goniometer is a crucial technology for serial diffraction of single molecules. PMID:27448887

  7. Helium diffusion in R7T7 nuclear glass investigated by NRA technique

    Energy Technology Data Exchange (ETDEWEB)

    Chamssedine, F.; Sauvage, T. [CNRS-CEMHTI, Site Cyclotron, 3A rue de la Ferollerie, 45071 Orleans Cedex2 (France); Peuget, S. [CEA Valrho-Marcoule, DEN/DTCD/SECM/LMPA, BP 17171, 30207 Bagnols-sur-Ceze cedex (France); Martin, G. [CEA Cadarache, DEC/DEN/SESC/LLCC, 13108 St Paul Lez Durance cedex (France)

    2008-07-01

    The mechanisms related to helium migration into R7T7 nuclear waste glass is studied from the evolution of the concentration profiles as a function of the annealing conditions. The presence of helium is simulated by implantation of 600 keV {sup 3}He ions into nuclear glass disks at 150 K. The fluence analyzed in this paper is 2.10{sup 16} at.cm{sup -2} (36.10{sup 19} at./g). Helium depth profile after the various annealing stages is determined by the {sup 3}He(d,{alpha}){sup 1}H Nuclear Reaction Analysis method. The results show the mobility of helium at temperature as low as 253 K. Simple modeling based on a diffusion process using a Fick's law is used to determinate, from the depth profile change, thermal diffusion coefficient D at temperatures in the range 253 K to 323 K. The activation energy was then estimated by Arrhenius plot at 0.54 {+-} 0.01 eV. (authors)

  8. Monte Carlo simulations of nanoscale focused neon ion beam sputtering.

    Science.gov (United States)

    Timilsina, Rajendra; Rack, Philip D

    2013-12-13

    A Monte Carlo simulation is developed to model the physical sputtering of aluminum and tungsten emulating nanoscale focused helium and neon ion beam etching from the gas field ion microscope. Neon beams with different beam energies (0.5-30 keV) and a constant beam diameter (Gaussian with full-width-at-half-maximum of 1 nm) were simulated to elucidate the nanostructure evolution during the physical sputtering of nanoscale high aspect ratio features. The aspect ratio and sputter yield vary with the ion species and beam energy for a constant beam diameter and are related to the distribution of the nuclear energy loss. Neon ions have a larger sputter yield than the helium ions due to their larger mass and consequently larger nuclear energy loss relative to helium. Quantitative information such as the sputtering yields, the energy-dependent aspect ratios and resolution-limiting effects are discussed.

  9. Doping of Green Fluorescent Protein into Superfluid Helium Droplets: Size and Velocity of Doped Droplets.

    Science.gov (United States)

    Alghamdi, Maha; Zhang, Jie; Oswalt, Andrew; Porter, Joseph J; Mehl, Ryan A; Kong, Wei

    2017-09-14

    We report doping of green fluorescent protein from an electrospray ionization (ESI) source into superfluid helium droplets. From analyses of the time profiles of the doped droplets, we identify two distinct groups of droplets. The faster group has a smaller average size, on the order of 10(6) helium atoms/droplet, and the slower group is much larger, by at least an order of magnitude. The relative populations of these two groups depend on the temperature of the droplet source: from 11 to 5 K, the signal intensity of the slower droplet group gradually increases, from near the detection limit to comparable to that of the faster group. We postulate that the smaller droplets are formed via condensation of gaseous helium upon expansion from the pulsed valve, while the larger droplets develop from fragmentation of ejected liquid helium. Our results on the size and velocity of the condensation peak at higher source temperatures (>7 K) agree with previous reports, but those at lower temperatures (<7 K) seem to be off. We attribute this discrepancy to the masking effect of the exceedingly large droplets from the fragmentation peak in previous measurements of droplet sizes. Within the temperature range of our investigation, although the expansion condition changes from subcritical to supercritical, there is no abrupt change in either the velocity distribution or the size distribution of the condensation peak, and the most salient effect is in the increasing intensity of the fragmentation peak. The absolute doping efficiency, as expressed by the ratio of ion-doped droplets over the total number of ions from the ESI source, is on the order of 10(-4), while only hundreds of doped ions have been detected. Further improvements in the ESI source are key to extending the technology for future experiments. On the other hand, the separation of the two groups of droplets in velocity is beneficial for size selection of only the smaller droplets for future experiments of electron

  10. Modification of graphene by ion beam

    Science.gov (United States)

    Gawlik, G.; Ciepielewski, P.; Jagielski, J.; Baranowski, J.

    2017-09-01

    Ion induced defect generation in graphene was analyzed using Raman spectroscopy. A single layer graphene membrane produced by chemical vapor deposition (CVD) on copper foil and then transferred on glass substrate was subjected to helium, carbon, nitrogen, argon and krypton ions bombardment at energies from the range 25 keV to 100 keV. A density of ion induced defects and theirs mean size were estimated by using Raman measurements. Increasing number of defects generated by ion with increase of ion mass and decrease of ion energy was observed. Dependence of ion defect efficiency (defects/ion) on ion mass end energy was proportional to nuclear stopping power simulated by SRIM. No correlation between ion defect efficiency and electronic stopping power was observed.

  11. Photoassociation of cold metastable helium atoms

    NARCIS (Netherlands)

    Woestenenk, G.R.

    2001-01-01

    During the last decades the study of cold atoms has grown in a great measure. Research in this field has been made possible due to the development of laser cooling and trapping techniques. We use laser cooling to cool helium atoms down to a temperature of 1 mK and we are able to

  12. Parametric study of radiofrequency helium discharge under ...

    Indian Academy of Sciences (India)

    The excitation temperatures in the α and γ modes were 3266 and 4500 K respectively, evaluated by Boltzmann's plot method. The estimated gas temperature increased from 335 K in the α mode to 485 K in the γ mode, suggesting that the radio frequency atmospheric pressure helium discharge can be used for surface ...

  13. Critical Landau Velocity in Helium Nanodroplets

    NARCIS (Netherlands)

    Brauer, N.B.; Smolarek, S.; Loginov, E.; Mateo, D.; Hernando, A.; Pi, M.; Barranco, M.; Buma, W.J.; Drabbels, M.

    2013-01-01

    The best-known property of superfluid helium is the vanishing viscosity that objects experience while moving through the liquid with speeds below the so-called critical Landau velocity. This critical velocity is generally considered a macroscopic property as it is related to the collective

  14. Helium and Sulfur Hexafluoride in Musical Instruments

    Science.gov (United States)

    Forinash, Kyle; Dixon, Cory L.

    2014-01-01

    The effects of inhaled helium on the human voice were investigated in a recent article in "The Physics Teacher." As mentioned in that article, demonstrations of the effect are a popular classroom activity. If the number of YouTube videos is any indication, the effects of sulfur hexafluoride on the human voice are equally popular.…

  15. Messer to provide helium for LHC

    CERN Multimedia

    2008-01-01

    Over the course of the next few years, industrial gas specialist The Messer Group, through its Swiss subsidiary Messer Schweiz AG, is to provide a 160,000kg supply of helium to the European Organisation for Nuclear Research (CERN) for the operation of the world's largest particle accelerator.

  16. Messer to provide helium for LHC project

    CERN Multimedia

    2008-01-01

    Over the course of the next few years, industrial gas specialist The Messer Group, through its Swiss subsidiary Messer Schweiz AG, is to provide a 160,000kg supply of helium to the European Organisation for Nuclear Research (CERN) for the operation of the world's largest particle accelerator.

  17. Near field characteristics of buoyant helium plumes

    Indian Academy of Sciences (India)

    affects the combustion. Puffing is also observed in low density gas plumes when the ratio of inlet ... generated using helium and helium–air mixtures, hot gases were used to understand the flow dynamics associated .... The glass lens acts as a filter to block any UV light and prevents fluorescence signal contamination. Since.

  18. Near field characteristics of buoyant helium plumes

    Indian Academy of Sciences (India)

    ... Lecture Workshops · Refresher Courses · Symposia · Live Streaming. Home; Journals; Sadhana; Volume 40; Issue 3. Near field characteristics of buoyant helium plumes. Kuchimanchi K Bharadwaj Debopam Das Pavan K Sharma. Section I – Fluid Mechanics and Fluid Power (FMFP) Volume 40 Issue 3 May 2015 pp 757- ...

  19. Thirty years of screw compressors for helium; Dreissig Jahre Schraubenkompressoren fuer Helium

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, H. [Kaeser Kompressoren GmbH, Coburg (Germany). Technisches Buero/Auftragskonstruktion

    2007-07-01

    KAESER helium compressors, as well as their other industrial compressors, will be further developed with the intention to improve the availability and reliability of helium liquefaction systems. Further improvement of compressor and control system efficiency will ensure a low and sustainable operating cost. Fast supply of replacement parts with several years of warranty is ensured by a world-wide distribution system and is also worked on continuously. (orig.)

  20. Femtosecond spectroscopy on alkali-doped helium nanodroplets; Femtosekundenspektroskopie an alkalidotierten Helium-Nanotroepfchen

    Energy Technology Data Exchange (ETDEWEB)

    Claas, P.

    2006-01-15

    In the present thesis first studies on the short-time dynamics in alkali dimers and microclusters, which were bound on the surface of superfluid helium droplets, were presented. The experiments comprehended pump-probe measurements on the fs scale on the vibration dynamics on the dimers and on the fragmentation dynamics on the clusters. Generally by the studies it was shown that such extremely short slopes can also be observed on helium droplets by means of the femtosecond spectroscopy.

  1. Evidence-based medicine. Understanding the basic concepts, the principles and the practice; Evidenz-basierte Medizin. Praxis-Handbuch fuer Verstaendnis und Anwendung der EBM

    Energy Technology Data Exchange (ETDEWEB)

    Antes, G.; Bassler, D.; Forster, J. (eds.)

    2003-07-01

    The toolbook is a practical guide explaining the basic concepts, methodology and working instruments of evidence-based medicine, (EbM). The goals of EbM and the pros and cons are addressed. The reader is taught how to efficiently apply the statistical tools and concepts for an evaluation of clinical trials, review articles, and meta analyses. [German] In diesem Buch werden die theoretischen Grundlagen der Evidenz-basierten Medizin verstaendlich und praxisnah erlaeutert und die Pros und Kontras vorgestellt. Ferner gibt das Buch eine detaillierte Anleitung zur eigenen Beurteilung von klinischen Studien, Uebersichtsarbeiten und Meta-Analysen und vermittelt Medizinern das notwendige statistische Handwerkszeug und Hintergrundwissen fuer die Anwendung der EBM in Praxis und Klinik. (orig.)

  2. Evaluation of helium cooling for fusion divertors

    Energy Technology Data Exchange (ETDEWEB)

    Baxi, C.B.

    1993-09-01

    The divertors of future fusion reactors will have a power throughput of several hundred MW. The peak heat flux on the diverter surface is estimated to be 5 to 15 MW/m{sup 2} at an average heat flux of 2 MW/m{sup 2}. The divertors have a requirement of both minimum temperature (100{degrees}C) and maximum temperature. The minimum temperature is dictated by the requirement to reduce the absorption of plasma, and the maximum temperature is determined by the thermo-mechanical properties of the plasma facing materials. Coolants that have been considered for fusion reactors are water, liquid metals and helium. Helium cooling has been shown to be very attractive from safety and other considerations. Helium is chemically and neutronically inert and is suitable for power conversion. The challenges associated with helium cooling are: (1) Manifold sizes; (2) Pumping power; and (3) Leak prevention. In this paper the first two of the above design issues are addressed. A variety of heat transfer enhancement techniques are considered to demonstrate that the manifold sizes and the pumping power can be reduced to acceptable levels. A helium-cooled diverter module was designed and fabricated by GA for steady-state heat flux of 10 MW/m{sup 2}. This module was recently tested at Sandia National Laboratories. At an inlet pressure of 4 MPa, the module was tested at a steady-state heat flux of 10 MW/m{sup 2}. The pumping power required was less than 1% of the power removed. These results verified the design prediction.

  3. Requirements for inverted roofs with separating layer - notes on the application of EN ISO 6946.; Anforderungen an Umkehrdaecher mit Trennlage: Erlaeuterungen zur Anwendung von EN ISO 6946

    Energy Technology Data Exchange (ETDEWEB)

    Leimer, Hans-Peter [Hochschule fuer angewandte Wissenschaft und Kunst, Hildesheim-Deutschland, BBS Institut Baukonstruktion, Bauphysik, Sanierungstechnik, Am Forst 27, D-38302 Wolfenbuettel (Germany); Bednar, Thomas; Dreyer, Juergen [Technische Universitaet Wien, Institut fuer Baustofflehre, Bauphysik und Brandschutz, Karlsplatz 13/206, A-1040 Wien (Austria); Kuenzel, Hartwig M. [Fraunhofer Institut fuer Bauphysik (IBP), Fraunhofer-Strasse 10, D-83626 Valley (Germany); Palier, Pierre [CSTB Centre Scientifique et Technique du Batiment, 11, rue Henri Picherit, F-44323 Nantes (France); Rode, Carsten [Technical University Copenhagen, Department of Civil Engineering, Anker Engelundswej 1, Building 101A, DK-2800 Kgs. Lungby (Sweden); Tejchmann-Konarzewski, Jacek [Technical University Gdansk, Department of Fundamentals of Building and Material Engineering, ul. G. Narutowicza 11/12, PL-80952 Gdansk-Wrzeszcz (Poland)

    2004-10-01

    This paper explains the application of the EN ISO 6946 standard for different regions in Europe in terms of heat losses through inverted roofs. For determining the heat transfer coefficient of inverted roofs, the October 2003 version of this standard takes into account additional heat loss due to precipitation. This enables additional roof heat losses originating from the flow of warmed precipitation below the thermal insulation to be calculated. The heat loss depends on the quantity of precipitation and on the proportion of water that drains directly between the roof sealing layer and the thermal insulation. The paper explains the application of the standard for different regions in Europe. Supplementary climatic data and boundary conditions for different regions are provided. In addition, the requirements for the separating layer in inverted roofs with separating layer are described. Using the technique described, heat losses due to precipitation can be reduced to such an extent that they are negligible for the purpose of the calculation. (Abstract Copyright [2004], Wiley Periodicals, Inc.) [German] Dieser Beitrag soll fuer unterschiedliche Regionen in Europa die Anwendung der Norm EN ISO 6946 im Hinblick auf Waermeverluste beim Umkehrdach erlaeutern. In der Fassung dieser Norm von Oktober 2003 wird bei der Bestimmung des Waermedurchgangskoeffizienten bei Umkehrdaechern ein zusaetzlicher, niederschlagsbedingter Waermeverlust beruecksichtigt. Die zusaetzlichen Waermeverluste eines Daches, die bedingt durch den Abfluss von erwaermten Niederschlaegen unterhalb der Waermedaemmung entstehen, koennen somit rechnerisch erfasst werden. Die Groesse der Waermeverluste ist abhaengig von der Niederschlagsmenge und dem Anteil der Wassermenge, die direkt zwischen Dachabdichtung und Waermedaemmung ablaeuft. Diese Veroeffentlichung soll die Anwendung der Norm fuer unterschiedliche Regionen in Europa erlaeutern. Hierzu werden ergaenzend Klimadaten und Randbedingungen

  4. The future of helium as a natural resource

    CERN Document Server

    Glowacki, Bartek A; Nuttall, William J

    2012-01-01

    The book reveals the changing dynamics of the helium industry on both the supply-side and the demand-side. The helium industry has a long-term future and this important gas will have a role to play for many decades to come. Major new users of helium are expected to enter the market, especially in nuclear energy (both fission and fusion). Prices and volumes supplied and expected to rise and this will prompt greater efforts towards the development of new helium sources and helium conservation and recycling.

  5. Hot solar-wind helium: direct evidence for local heating by Alfvén-cyclotron dissipation.

    Science.gov (United States)

    Kasper, J C; Lazarus, A J; Gary, S P

    2008-12-31

    A study of solar-wind hydrogen and helium temperature observations collected by the Wind spacecraft offers compelling evidence of heating by an Alfvén-cyclotron dissipation mechanism. Observations are sorted by the rate of Coulomb interactions, or collisional age, in the plasma and the differential flow between the two species. We show that helium is preferentially heated perpendicular to the magnetic field direction by more than a factor of 6 when the flow between the species is small relative to the Alfvén wave speed and collisions are infrequent. These signatures are consistent with predictions of dissipation in the presence of multiple ion species. We also report an unexpected result: observations of efficient heating of helium parallel to the magnetic field for large differential flow relative to the sound speed.

  6. Fire safety engineering for calculation of smokespread. Pt. 1; Anwendung ingenieurmaessiger Verfahren zur Bestimmung der Rauchausbreitung. T. 1

    Energy Technology Data Exchange (ETDEWEB)

    Max, U. [Arbeitsgemeinschaft Brandsicherheit (AGB), Bruchsal (Germany); Schneider, U.; Lebeda, C. [Technische Universitaet Vienna (Austria). Inst. fuer Baustofflehre, Bauphysik und Brandschutz

    2000-08-01

    unter Beteiligung der Bauaufsicht definiert und abgestimmt werden. Am Beispiel des von der Arbeitsgemeinschaft Brandsicherheit (AGB) entwickelten und betriebenen Brandschutz-Rechenprogramms MRFC in der Version 2.6 werden die allgemeinen Grundsaetze der Modellierung vorgestellt. Am Beispiel einer Untersuchung zur Wirksamkeit von Rauchabzugseinrichtungen mit natuerlicher Rauchabfuhr werden die entsprechenden Brandsimulationsrechnungen exemplarisch fuer ausgewaehlte Rechenergebnisse vorgestellt. Mit den Berechnungen kann u.a. nachgewiesen werden, dass mit dem Rechenprogramm MRFC die normativen Festlegungen in DIN 18232-2 i.a. gut nachvollzogen werden koennen. Fuer eine weitere Anwendbarkeit und zur Verbesserung der Akzeptanz muessen die verfuegbaren oder neu entwickelte Brandmodelle mittel- und langfristig weiter verifiziert werden. Dazu sind Grossversuche erforderlich, die auch unter dem Gesichtspunkt der Klaerung von Modellierungsunsicherheiten so vorbereitet werden muessen, dass die Messergebnisse mit den Rechenprogrammen nachvollzogen werden koennen und auch Aussagen zu speziellen Problemen, fuer die derzeit ingenieurmaessige Ansaetze verwendet werden, liefern koennen. Fuer die baupraktische Anwendung von Brandsimulationsrechnungen sind 'Design Fires', d.h. Bemessungsbrandszenarien, erforderlich, die aus den derzeit vorliegenden Erfahrungen abgeleitet werden koennen. Diese 'Design Fires' muessen auf der sicheren Seite liegende Beschreibungen von moeglichen Brandverlaeufen in Gebaeuden sein, die auch die vorgesehene Nutzung und die brandschutztechnische Infrastruktur, z.B. die Branderkennung und -bekaempfung, beruecksichtigen. Diese Festlegungen sind als 'Lastannahmen' fuer das Brandschutzingenieurwesen unerlaesslich. (orig.)

  7. Review of Membranes for Helium Separation and Purification

    Science.gov (United States)

    Scholes, Colin A.; Ghosh, Ujjal K.

    2017-01-01

    Membrane gas separation has potential for the recovery and purification of helium, because the majority of membranes have selectivity for helium. This review reports on the current state of the research and patent literature for membranes undertaking helium separation. This includes direct recovery from natural gas, as an ancillary stage in natural gas processing, as well as niche applications where helium recycling has potential. A review of the available polymeric and inorganic membranes for helium separation is provided. Commercial gas separation membranes in comparable gas industries are discussed in terms of their potential in helium separation. Also presented are the various membrane process designs patented for the recovery and purification of helium from various sources, as these demonstrate that it is viable to separate helium through currently available polymeric membranes. This review places a particular focus on those processes where membranes are combined in series with another separation technology, commonly pressure swing adsorption. These combined processes have the most potential for membranes to produce a high purity helium product. The review demonstrates that membrane gas separation is technically feasible for helium recovery and purification, though membranes are currently only applied in niche applications focused on reusing helium rather than separation from natural sources. PMID:28218644

  8. Klinische Anwendung der Densitometrie

    Directory of Open Access Journals (Sweden)

    Grampp S

    2002-01-01

    Full Text Available Eine frühe Diagnose der Osteoporose und eine genaue Messung von Behandlungserfolgen stehen im Mittelpunkt der radiologischen Bestrebungen. Die häufigsten klinisch angewendeten Methoden, um das periphere Skelett sowie das Achsenskelett zu beurteilen, sind die Zwei-Spektren-Röntgenabsorptiometrie (DXA = dual x-ray absorptiometry und die quantitative Computertomographie (QCT, die zusammen mit den konventionellen Röntgenaufnahmen die sogenannten Standardverfahren darstellen. Generell werden die Meßergebnisse eines Individuums mit einer alters-, geschlechts- und rassenspezifischen Kontrollgruppe verglichen. In diesem Zusammenhang ist die Bestimmung der Knochenmasse ein Indikator des künftigen Frakturrisikos eines Patienten. Die radiologische Diagnose der Osteoporose kann durch die Bestimmung der Knochenmasse erfolgen, auch wenn keine prävalenten Frakturen vorliegen. Die Wahl des Meßortes und der Untersuchungstechnik zur Bestimmung der Knochenmasse oder des Frakturrisikos muß sich nach individuellen Gegebenheiten am Patienten sowie den Stärken und Limitationen der verschiedenen Techniken richten.

  9. Measurement of O and OH radical produced by an atmospheric-pressure helium plasma jet nearby rat skin

    Science.gov (United States)

    Yonemori, Seiya; Ono, Ryo

    2013-09-01

    Atmospheric-pressure helium plasma jet is getting much attention because it enables many kinds of plasma applications including biomedical application such as sterilization and cancer treatment. In biomedical plasma applications, it is though that active species like ions and radicals play important role. Especially, OH radical and O atom is very chemically reactive that they are deemed as major factors in cancer treatment. In this study, O and OH density distribution and its temporal behavior nearby rat skin were measured to demonstrate actual application. Plasma discharge was under AC10 kVp-p, 10 kHz with 1.5 slm (standard litter per minute) of helium gas flow. OH density was around 1 ppm and O atom density was around 10 ppm at maximum. We also measured time-evolution of OH and O atom density. Both OH and O density was almost constant between discharge pulses because lifetime of active species could be prolonged in helium. And density distribution of both species varied depending on helium flow rate and water concentration on the surface; on rat skin or on the grass surface. Those results suggest the production mechanisms and provision mechanisms of O atom and OH radical by an atmospheric-pressure helium plasma jet. This work is partially supported by the Grant-in-Aid for Science Research by the Ministry of Education, Culture, Sport, Science and Technology.

  10. Damage behavior in helium-irradiated reduced-activation martensitic steels at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Fengfeng [Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Hubei Nuclear Solid Physics Key Laboratory and School of Physics and Technology, Wuhan University, Wuhan 430072 (China); Guo, Liping, E-mail: guolp@whu.edu.cn [Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Hubei Nuclear Solid Physics Key Laboratory and School of Physics and Technology, Wuhan University, Wuhan 430072 (China); Chen, Jihong; Li, Tiecheng; Zheng, Zhongcheng [Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Hubei Nuclear Solid Physics Key Laboratory and School of Physics and Technology, Wuhan University, Wuhan 430072 (China); Yao, Z. [Department of Mechanical and Materials Engineering, Queen’s University, Kingston K7L 3N6, ON (Canada); Suo, Jinping [State Key Laboratory of Mould Technology, Institute of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2014-12-15

    Dislocation loops induced by helium irradiation at elevated temperatures in reduced-activation martensitic steels were investigated using transmission electron microscopy. Steels were irradiated with 100 keV helium ions to 0.8 dpa between 300 K and 723 K. At irradiation temperatures T{sub irr} ⩽ 573 K, small defects with both Burger vectors b = 1/2〈1 1 1〉 and b = 〈1 0 0〉 were observed, while at T{sub irr} ⩾ 623 K, the microstructure was dominated by large convoluted interstitial dislocation loops with b = 〈1 0 0〉. Only small cavities were found in the steels irradiated at 723 K.

  11. Effect of composition on helium diffusion in fluoroapatites investigated with nuclear reaction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Miro, S. [CRISMAT, ENSICAEN, 6 Bd du Marechal Juin, F-14050 Caen cedex (France); Studer, F. [CRISMAT, ENSICAEN, 6 Bd du Marechal Juin, F-14050 Caen cedex (France); Costantini, J.-M. [CEA Saclay, DMN/SRMA, F-91191 Gif-sur-Yvette cedex (France)]. E-mail: jean-marc.costantini@cea.fr; Haussy, J. [CEA DIF, DCRE/SEIM, BP 12, F-91680 Bruyeres-le-Chatel cedex (France); Trouslard, P. [CEA Saclay, LEMFI/INSTN/DRECAM, F-91191 Gif-sur-Yvette cedex (France); Grob, J.-J. [CNRS-InESS, 23, rue du Loess, B.P.20, F-67037 Strasbourg cedex (France)

    2006-09-01

    In the context of nuclear waste disposal, the knowledge of the diffusion of helium produced by {alpha}-decays is an important issue, in order to assess the long-term behavior of the containment matrices. Apatite is one of these potential hosts, which can incorporate many radionuclides as trivalent minor actinides and fission products. In order to determine the influence of the double (cationic/anionic) substitution on helium diffusion, we have studied two different apatite compositions (Ca{sub 10}(PO{sub 4}){sub 6}F{sub 2} and Ca{sub 4}Nd{sub 6}(SiO{sub 4}){sub 6}F{sub 2}). For that purpose, the helium bulk diffusion constants were derived from non-destructive {sup 3}He depth profiling using the {sup 3}He(d,p){sup 4}He nuclear reaction. Results have been obtained on sintered ceramics implanted with 3-MeV {sup 3}He{sup +} ions at a depth around 9 {mu}m with a fluence of 10{sup 16} ions cm{sup -2} then annealed in air at temperatures between 250 and 400 deg. C. We show that the activation energy for helium diffusion determined by two different models decreases with substitution, i.e., 1.27 eV for Ca{sub 10}(PO{sub 4}){sub 6}F{sub 2} and 0.89 eV for Ca{sub 4}Nd{sub 6}(SiO{sub 4}){sub 6}F{sub 2}. Moreover, the activation energy in sintered Ca{sub 10}(PO{sub 4}){sub 6}F{sub 2} ceramics is similar to that determined by other authors on a single crystal of the same composition. It leads us to think that the diffusion mechanism involves the tunnels of the structure, the size of which increases with substitution.

  12. Survivor from asphyxiation due to helium inhalation

    Directory of Open Access Journals (Sweden)

    Massimiliano Etteri

    2016-06-01

    Full Text Available In this rare case report we describe a 27- year-old white man survived to suicide by asphyxiation using the so-called suicide bag (or exit bag filled with helium supplied through a plastic tube. He had no previous psychiatric or organic illnesses. At the time of presentation to our Emergency Department he was awake and reported severe dyspnea with a clinical pattern of acute respiratory failure. Imaging studies showed pulmonary edema and the patient was treated with non-invasive ventilation in Intensive Care Unit. After 15 days the patient was discharged from hospital in optimal conditions. These rare cases of survivor might suggest the possible causes of death from inhaling helium.

  13. Detection of charged particles in superfluid helium

    Energy Technology Data Exchange (ETDEWEB)

    Bandler, Simon R. [Brown Univ., Providence, RI (United States)

    1994-12-01

    This thesis is concerned with the use of a large superfluid helium detector for the detection of solar neutrinos. A small-scale prototype of this type of detector has been constructed and tested. In this thesis the author discussed in detail the design of the apparatus, the experiments which have been carried out, and what has been learned about the important physical processes involved in this type of detector. These processes include the anisotropic generation of phonons and rotons by the recoiling particle, the propagation of the phonons and rotons in the liquid, the evaporation process at the liquid surface, and the adsorption of the helium atoms onto the wafers. In addition he discusses the generation and detection of fluorescent photons from recoiling particles. The implications of these results to the design of a full-scale detector of neutrinos are discussed.

  14. THERMAL OSCILLATIONS IN LIQUID HELIUM TARGETS.

    Energy Technology Data Exchange (ETDEWEB)

    WANG,L.; JIA,L.X.

    2001-07-16

    A liquid helium target for the high-energy physics was built and installed in the proton beam line at the Alternate Gradient Synchrotron of Brookhaven National Laboratory in 2001. The target flask has a liquid volume of 8.25 liters and is made of thin Mylar film. A G-M/J-T cryocooler of five-watts at 4.2K was used to produce liquid helium and refrigerate the target. A thermosyphon circuit for the target was connected to the J-T circuit by a liquid/gas separator. Because of the large heat load to the target and its long transfer lines, thermal oscillations were observed during the system tests. To eliminate the oscillation, a series of tests and analyses were carried out. This paper describes the phenomena and provides the understanding of the thermal oscillations in the target system.

  15. Laser-Induced Breakdown in Liquid Helium

    Science.gov (United States)

    Sirisky, S.; Yang, Y.; Wei, W.; Maris, H. J.

    2017-10-01

    We report on experiments in which focused laser light is used to induce optical breakdown in liquid helium-4. The threshold intensity has been measured over the temperature range from 1.1 to 2.8 K with light of wavelength 1064 nm. In addition to the measurement of the threshold, we have performed experiments to study how the breakdown from one pulse modifies the probability that a subsequent pulse will result in breakdown.

  16. Combined cold compressor/ejector helium refrigerator

    Science.gov (United States)

    Brown, Donald P.

    1985-01-01

    A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

  17. Correlation of Helium Solubility in Liquid Nitrogen

    Science.gov (United States)

    VanDresar, Neil T.; Zimmerli, Gregory A.

    2012-01-01

    A correlation has been developed for the equilibrium mole fraction of soluble gaseous helium in liquid nitrogen as a function of temperature and pressure. Experimental solubility data was compiled and provided by National Institute of Standards and Technology (NIST). Data from six sources was used to develop a correlation within the range of 0.5 to 9.9 MPa and 72.0 to 119.6 K. The relative standard deviation of the correlation is 6.9 percent.

  18. Helium refrigeration system for hydrogen liquefaction applications

    Science.gov (United States)

    Nair, J. Kumar, Sr.; Menon, RS; Goyal, M.; Ansari, NA; Chakravarty, A.; Joemon, V.

    2017-02-01

    Liquid hydrogen around 20 K is used as cold moderator for generating “cold neutron beam” in nuclear research reactors. A cryogenic helium refrigeration system is the core upon which such hydrogen liquefaction applications are built. A thermodynamic process based on reversed Brayton cycle with two stage expansion using high speed cryogenic turboexpanders (TEX) along with a pair of compact high effectiveness process heat exchangers (HX), is well suited for such applications. An existing helium refrigeration system, which had earlier demonstrated a refrigeration capacity of 470 W at around 20 K, is modified based on past operational experiences and newer application requirements. Modifications include addition of a new heat exchanger to simulate cryogenic process load and two other heat exchangers for controlling the temperatures of helium streams leading out to the application system. To incorporate these changes, cryogenic piping inside the cold box is suitably modified. This paper presents process simulation, sizing of new heat exchangers as well as fabrication aspects of the modified cryogenic process piping.

  19. Optical traps for ultracold metastable helium atoms

    Energy Technology Data Exchange (ETDEWEB)

    Simonet, Juliette [LKB ENS, Paris (France)

    2009-07-01

    One of the main characteristics of metastable helium atoms is their high internal energy (20 eV). This energy can be released when a metastable atom hits a surface, ejecting one electron. Therefore, using a Channeltron Electron Multiplier (CEM), one can detect atoms with a time resolution of up to 5 ns. However, this high internal energy raises the problem of inelastic Penning ionizations, following: He{sup *}+He{sup *}{yields}He+He{sup +}+e{sup *}. This process has a rate of the order of 10 x 10 cm{sup 3} cot s{sup -}1 but is reduced by four orders of magnitude if the atoms are spin polarized due to total spin conservation. We report on the progress of the set up of a dipole trap for ultracold metastable helium using a red detuned fiber laser at 1560 nm. One of the aims of this optical trap is to release the constraint on the magnetic field value. We plan to measure the magnetic field dependance of inelastic collision rates for temperatures smaller than 10 {mu}K. In a spin polarized gas of helium, the spin-spin interaction produces spin relaxation and relaxation induced Penning ionization if the polarization condition is no longer maintained. We also present the development of a optical lattices in 1D and later in 3D. We intend to monitor the Penning ionization rate in order to follow the real-time dynamics of the superfluid-Mott insulator quantum phase transition.

  20. Laser Spectroscopy of Antiprotonic Helium Atoms

    CERN Multimedia

    2002-01-01

    %PS205 %title\\\\ \\\\Following the discovery of metastable antiprotonic helium atoms ($\\overline{p}He^{+} $) at KEK in 1991, systematic studies of their properties were made at LEAR from 1991 to 1996. In the first two years the lifetime of $\\overline{p}He^{+}$ in liquid and gaseous helium at various temperatures and pressures was measured and the effect of foreign gases on the lifetime of these atoms was investigated. Effects were also discovered which gave the antiproton a 14\\% longer lifetime in $^4$He than in $^3$He, and resulted in important differences in the shape of the annihilation time spectra in the two isotopes.\\\\ \\\\Since 1993 laser spectroscopy of the metastable $\\overline{p}He^{+}$ atoms became the main focus of PS205. Transitions were stimulated between metastable and non-metastable states of the $\\overline{p}He^{+}$ atom by firing a pulsed dye laser beam into the helium target every time an identified metastable atom was present (Figure 1). If the laser frequency matched the transition energy, the...

  1. Scanning ion microscopy with low energy lithium ions

    Energy Technology Data Exchange (ETDEWEB)

    Twedt, Kevin A. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Maryland NanoCenter, University of Maryland, College Park, MD 20742 (United States); Chen, Lei [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); McClelland, Jabez J., E-mail: jabez.mcclelland@nist.gov [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States)

    2014-07-01

    Using an ion source based on photoionization of laser-cooled lithium atoms, we have developed a scanning ion microscope with probe sizes of a few tens of nanometers and beam energies from 500 eV to 5 keV. These beam energies are much lower than the typical operating energies of the helium ion microscope or gallium focused ion beam systems. We demonstrate how low energy can be advantageous in ion microscopy when detecting backscattered ions, due to a decreased interaction volume and the potential for surface sensitive composition analysis. As an example application that demonstrates these advantages, we non-destructively image the removal of a thin residual resist layer during plasma etching in a nano-imprint lithography process. - Highlights: • We use an ion source based on photoionization of laser-cooled lithium atoms. • The ion source makes possible a low energy (500 eV to 5 keV) scanning ion microscope. • Low energy is preferred for ion microscopy with backscattered ions. • We use the microscope to image a thin resist used in nano-imprint lithography.

  2. Investigation of intermittent enhancement of ion emission from a tungsten surface using the field-ion microscope.

    Science.gov (United States)

    Weizer, V. G.

    1971-01-01

    The blinking effect, or the intermittent enhancement of ion emission, which is observed when a few parts per million neon are added to the imaging gas in a helium-tungsten field-ion microscope, has been investigated. Measurements of the characteristic quantities involved - i.e., blinking rate, voltage limits, etc. - and their variation with temperature, field, and gas pressure, are described.

  3. Diode Laser Based LIF Diagnostics for Argon and Helium Plasmas.

    Science.gov (United States)

    Stolzenberg, E.; Boivin, R. F.; Compton, C.; Hardin, R.; Keesee, A.; Kline, J. L.; Scime, E. E.

    2002-11-01

    A diode laser based Laser Induced Fluorescence (LIF) diagnostic that uses an inexpensive diode laser system is presented. The same diode laser is used to pump Ar II and He I transitions to obtain the ion and the neutral temperature of the respective species. The 1 MHz bandwidth diode laser has a Littrow external cavity with a mode-hop free tuning range up to 15 GHz and with a total power output of about 10 mWatt. The wavelength is measured by a wavemeter and frequent monitoring prevent wavelength drift. For the argon ion population, the laser tuned at 668.61 nm, is used to pump the 3d4F7/2 Ar II metastable level to the 4p4D5/2 excited level. The fluorescence radiation between the 4p4D5/2 and the 4s4P3/2 levels (442.6 nm) is monitored by a photomultiplier detector. For neutral helium, the laser is tuned at 667.82 nm to pump a fraction of the electron population from the 21P state to the 31D upper level. Although the 21P level is not a metastable state, the close proximity of 21S metastable level makes this new He I LIF possible in collisional plasmas. Some electrons of this 31D level undergo collisional excitation transfer (optically allowed transition) to the 31P. In turn, this state decay to the metastable 21S by emitting 501.6 nm fluorescence photons. The new LIF diagnostic has been developed at West Virginia University (WVU) and tested on the Hot hELIcon eXperiment (HELIX) plasma device. Ion and neutral temperatures obtained using this new LIF diagnostic are presented and compared to previous measurements performed with a more expensive and elaborate ring dye laser system.

  4. In situ controlled modification of the helium density in single helium-filled nanobubbles

    Energy Technology Data Exchange (ETDEWEB)

    David, M.-L., E-mail: marie-laure.david@univ-poitiers.fr; Pailloux, F. [Institut Pprime, UPR 3346 CNRS-Université de Poitiers, SP2MI, 86962 Futuroscope-Chasseneuil cedex (France); Canadian Centre for Electron Microscopy, Mc Master University, 1280 Main Street West, Hamilton, Ontario L8S 4M1 (Canada); Alix, K.; Mauchamp, V.; Pizzagalli, L. [Institut Pprime, UPR 3346 CNRS-Université de Poitiers, SP2MI, 86962 Futuroscope-Chasseneuil cedex (France); Couillard, M.; Botton, G. A. [Canadian Centre for Electron Microscopy, Mc Master University, 1280 Main Street West, Hamilton, Ontario L8S 4M1 (Canada); Department of Materials Science and Engineering, Mc Master University, 1280 Main Street West, Hamilton, Ontario L8S 4M1 (Canada)

    2014-03-28

    We demonstrate that the helium density and corresponding pressure can be modified in single nano-scale bubbles embedded in semiconductors by using the electron beam of a scanning transmission electron microscope as a multifunctional probe: the measurement probe for imaging and chemical analysis and the irradiation source to modify concomitantly the pressure in a controllable way by fine tuning of the electron beam parameters. The control of the detrapping rate is achieved by varying the experimental conditions. The underlying physical mechanisms are discussed; our experimental observations suggest that the helium detrapping from bubbles could be interpreted in terms of direct ballistic collisions, leading to the ejection of the helium atoms from the bubble.

  5. Retention of hydrogen isotopes and helium in nickel

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Mitsumasa; Sato, Rikiya; Yamaguchi, Kenji; Yamawaki, Michio [Tokyo Univ., Tokai, Ibaraki (Japan). Nuclear Engineering Research Lab.

    1996-10-01

    In the present study, a thin foil of nickel was irradiated by H{sub 2}{sup +}, D{sub 2}{sup +} and He{sup +} to a fluence of 1.2-6.0x10{sup 20}/m{sup 2} using the TBTS (Tritium Beam Test System) apparatus. The thermal desorption spectroscopy (TDS) technique was employed to evaluate the total amount of retained hydrogen isotope and helium atoms in nickel. In the spectra, two peaks appeared at 440-585K and 720-735K for helium. Hydrogen isotopes irradiation after helium preirradiation were found to enhance the helium release and to decrease the peak temperatures. Helium irradiation after hydrogen isotopes preirradiation were found to enhance the helium release, but the peak temperature showed little difference from that without preirradiation. (author)

  6. Capacity enhancement of indigenous expansion engine based helium liquefier

    Science.gov (United States)

    Doohan, R. S.; Kush, P. K.; Maheshwari, G.

    2017-02-01

    Development of technology and understanding for large capacity helium refrigeration and liquefaction at helium temperature is indispensable for coming-up projects. A new version of helium liquefier designed and built to provide approximately 35 liters of liquid helium per hour. The refrigeration capacity of this reciprocating type expansion engine machine has been increased from its predecessor version with continuous improvement and deficiency debugging. The helium liquefier has been built using components by local industries including cryogenic Aluminum plate fin heat exchangers. Two compressors with nearly identical capacity have been deployed for the operation of system. Together they consume about 110 kW of electric power. The system employs liquid Nitrogen precooling to enhance liquid Helium yield. This paper describes details of the cryogenic expander design improvements, reconfiguration of heat exchangers, performance simulation and their experimental validation.

  7. Kinematically complete investigation of momentum transfer for single ionization in fast proton-helium collisions

    Energy Technology Data Exchange (ETDEWEB)

    Weber, T.; Mergel, V.; Jagutzki, O.; Schmidt, L.; Afaneh, F.; Schmidt-Boecking, H. [Institut fuer Kernphysik, August-Euler-Strasse 6, 60486 Frankfurt am Main (Germany); Khayyat, K. [Department of Physics, University of Missouri, Rolla, MO (United States); Doerner, R. [Fakultaet fuer Physik, Universitaet Freiburg (Germany); Gonzalez, A. [Centro Atomico Bariloche, 8400 S C de Bariloche (Argentina); Cocke, C.L. [Department of Physics, Kansas State University, Manhatten, KS (United States); Landers, A.L. [Department of Physics, Western Michigan University, Kalamazoo, MI (United States)

    2000-09-14

    The dynamics of singly ionizing proton-helium collisions have been studied experimentally for several energies of the projectile (0.2, 0.5, 1.0 and 1.3 MeV) with the technique of cold target recoil-ion momentum spectroscopy (COLTRIMS). The complete final-state distribution in momentum space of all three particles was determined by measuring the three momentum components of the emitted electron and the coincident recoiling target ion. The momentum transfer and energy loss of the outgoing projectile was determined by momentum and energy conservation laws. Doubly differential cross sections of the kinematically complete experimental investigation are presented. The present data are compared with results from fast highly charged heavy-ion impact experiments. (author)

  8. Helium induces preconditioning in human endothelium in vivo.

    Science.gov (United States)

    Smit, Kirsten F; Oei, Gezina T M L; Brevoord, Daniel; Stroes, Erik S; Nieuwland, Rienk; Schlack, Wolfgang S; Hollmann, Markus W; Weber, Nina C; Preckel, Benedikt

    2013-01-01

    Helium protects myocardium by inducing preconditioning in animals. We investigated whether human endothelium is preconditioned by helium inhalation in vivo. Forearm ischemia-reperfusion (I/R) in healthy volunteers (each group n = 10) was performed by inflating a blood pressure cuff for 20 min. Endothelium-dependent and endothelium-independent responses were measured after cumulative dose-response infusion of acetylcholine and sodium nitroprusside, respectively, at baseline and after 15 min of reperfusion using strain-gauge, venous occlusion plethysmography. Helium preconditioning was applied by inhalation of helium (79% helium, 21% oxygen) either 15 min (helium early preconditioning [He-EPC]) or 24 h before I/R (helium late preconditioning). Additional measurements of He-EPC were done after blockade of endothelial nitric oxide synthase. Plasma levels of cytokines, adhesion molecules, and cell-derived microparticles were determined. Forearm I/R attenuated endothelium-dependent vasodilation (acetylcholine) with unaltered endothelium-independent response (sodium nitroprusside). Both He-EPC and helium late preconditioning attenuated I/R-induced endothelial dysfunction (max increase in forearm blood flow in response to acetylcholine after I/R was 180 ± 24% [mean ± SEM] without preconditioning, 573 ± 140% after He-EPC, and 290 ± 32% after helium late preconditioning). Protection of helium was comparable to ischemic preconditioning (max forearm blood flow 436 ± 38%) and was not abolished after endothelial nitric oxide synthase blockade. He-EPC did not affect plasma levels of cytokines, adhesion molecules, or microparticles. Helium is a nonanesthetic, nontoxic gas without hemodynamic side effects, which induces early and late preconditioning of human endothelium in vivo. Further studies have to investigate whether helium may be an instrument to induce endothelial preconditioning in patients with cardiovascular risk factors.

  9. Modelling third harmonic ion cyclotron acceleration of deuterium beams for JET fusion product studies experiments

    DEFF Research Database (Denmark)

    Schneider, M.; Johnson, T.; Dumont, R.

    2016-01-01

    Recent JET experiments have been dedicated to the studies of fusion reactions between deuterium (D) and Helium-3 (3He) ions using neutral beam injection (NBI) in synergy with third harmonic ion cyclotron radio-frequency heating (ICRH) of the beam. This scenario generates a fast ion deuterium tail...

  10. Asteroseismic estimate of helium abundance of 16 Cyg A, B

    Directory of Open Access Journals (Sweden)

    Verma Kuldeep

    2015-01-01

    Full Text Available The helium ionization zone in a star leaves a characteristic signature on its oscillation frequencies, which can be used to estimate the helium content in the envelope of the star. We use the oscillation frequencies of 16 Cyg A and B, obtained using 2.5 years of Kepler data, to estimate the envelope helium abundance of these stars. We find the envelope helium abundance to lie in the range 0.231–0.251 for 16 Cyg A and 0.218–0.266 for 16 Cyg B.

  11. Helium vs. Proton Induced Displacement Damage in Electronic Materials

    Science.gov (United States)

    Ringo, Sawnese; Barghouty, A. F.

    2010-01-01

    In this project, the specific effects of displacement damage due to the passage of protons and helium nuclei on some typical electronic materials will be evaluated and contrasted. As the electronic material absorbs the energetic proton and helium momentum, degradation of performance occurs, eventually leading to overall failure. Helium nuclei traveling at the same speed as protons are expected to impart more to the material displacement damage; due to the larger mass, and thus momentum, of helium nuclei compared to protons. Damage due to displacement of atoms in their crystalline structure can change the physical properties and hence performance of the electronic materials.

  12. Meas.of the Ratio Between Double and Single Ionization of Helium for Antiprotons

    CERN Multimedia

    2002-01-01

    The aim of this experiment is to measure the ratio between double and single ionization of helium by antiprotons in the energy range $>$~3~MeV. Comparison with already existing proton data will yield information on the mechanisms for double ionization, which could not be extracted from previous comparisons between ratios measured for equivelocity electrons and protons. The most basic information to be obtained from an antiproton experiment will be the amount of correlation existing between the two electrons in the ground-state helium atom.\\\\ \\\\ The equipment consists of a gas cell, which employs slow-ion collection via the so-called condenser-plate method for the absolute sum of partial-ionization cross sections and determination of the relative contribution of multiple charged ions by TOF. The gas cell has movable entrance and exit slits and a grid system to account for secondary emission from the collection of slow ions. Together with a field of 800~V/cm in the collision region, the potentials of the TOF sp...

  13. Strain measurement in helium implanted polycristal using image analysis in laue Micro X-ray diffraction patterns

    OpenAIRE

    IBRAHIM, Marcelle; CASTELLIER, Etienne; Palancher, Hervé; RICHARD, Axel; Goudeau, P.; Bornert, Michel; Care, Sabine

    2013-01-01

    In order to study the long term behaviour of used nuclear fuel, UO2 polycrystalline samples were implanted by Helium ions. The thin implanted layer, close to the sample surface, is elastically stressed. X-ray micro-diffraction (X- XRD) can be used to measure the induced strain on about 700 different grains of the polycrystal. Image analysis on the Laue diffraction patterns is required for an accurate strain estimation. Three methods to interpret the Laue pattern are developped in this study. ...

  14. Helium-filled proportional counter and its operation mechanism at low temperatures

    CERN Document Server

    Isozumi, Y; Kishimoto, S

    2002-01-01

    The operation mechanism of helium-filled proportional counter (HFPC) at about 4.2 K is explained. Unstable behavior of HFPC is caused by releasing secondary-electron from the cathode by four kinds of active particles such as He sub n sup + , non-resonance photon from excited helium atom, non-resonance photon from He sub 2 sup * (A sup 1 Su sup +) and He sub 2 sup m (a sup 3 Su sup +). On experiments of HFPC behavior at low temperature, the following facts were observed; 1) main charge formation process in the electron avalanche is direct ionization by electron without Hornbeck-Molnar process. Accordingly, the gas amplification factor becomes small at low temperature. 2) Stable helium cation is He sub 2 sup + at room temperature, but cluster at low temperature. Large after-pulse is observed in output signal depends on cluster ion. The probability of secondary-electron emission decreased. The gas gain increased with increasing anode voltage. 3) By decreasing reaction rate of atom and molecule collision at low t...

  15. Measurement of sputtered beryllium yield and angular distribution during nanostructure growth in a helium plasma

    Science.gov (United States)

    Hollmann, E. M.; Alegre, D.; Baldwin, M. J.; Chrobak, C. P.; Doerner, R. P.; Miyamoto, M.; Nishijima, D.

    2017-09-01

    The angular distribution and sputtering yield of beryllium exposed to helium plasma are estimated from analysis of line-integrated 2D imaging of Be-I line emission in a steady-state linear plasma device. As the surface nanostructure forms during plasma exposure on a ˜100 s timescale (corresponding to a fluence of order 1020/cm2) from nearly mono-energetic ion bombardment, a narrowing of the beryllium sputtering angle and a significant (˜5×) drop in sputtering yield are observed. These trends are found to be qualitatively consistent with modeling taking into account the effect of the surface morphology on sputtering yield and angular distribution.

  16. Nanostructure formation on silicon surfaces by using low energy helium plasma exposure

    Science.gov (United States)

    Takamura, Shuichi; Kikuchi, Yusuke; Yamada, Kohei; Maenaka, Shiro; Fujita, Kazunobu; Uesugi, Yoshihiko

    2016-12-01

    A new technology for obtaining nanostructure on silicon surface for potential applications to optical devices is represented. Scanning electron microscope analysis indicated a grown nanostructure of dense forest consisting of long cylindrical needle cones with a length of approximately 300 nm and a mutual distance of approximately 200 nm. Raman spectroscopy and spectrophotometry showed a good crystallinity and photon trapping, and reduced light reflectance after helium plasma exposure. The present technique consists of a simple maskless process that circumvents the use of chemical etching liquid, and utilizes soft ion bombardment on silicon substrate, keeping a good crystallinity.

  17. Microstructure Evolution and Mechanical Response of Nanolaminate Composites Irradiated with Helium at Elevated Temperatures

    Science.gov (United States)

    Li, Nan; Demkowicz, Michael J.; Mara, Nathan A.

    2017-11-01

    We summarize recent work on helium (He) interaction with various heterophase boundaries under high temperature irradiation. We categorize the ion-affected material beneath the He-implanted surface into three regions of depth, based on the He/vacancy ratio. The differing defect structures in these three regions lead to the distinct temperature sensitivity of He-induced microstructure evolution. The effect of He bubbles or voids on material mechanical performance is explored. Overall design guidelines for developing materials where He-induced damage can be mitigated in materials are discussed.

  18. The antimicrobial effects of helium and helium-air plasma on Staphylococcus aureus and Clostridium difficile.

    Science.gov (United States)

    Galvin, S; Cahill, O; O'Connor, N; Cafolla, A A; Daniels, S; Humphreys, H

    2013-08-01

    Healthcare-associated infections (HCAI) affect 5-10% of acute hospital admissions. Environmental decontamination is an important component of all strategies to prevent HCAI as many bacterial causes survive and persist in the environment, which serve as ongoing reservoirs of infection. Current approaches such as cleaning with detergents and the use of chemical disinfectant are suboptimal. We assessed the efficacy of helium and helium-air plasma in killing Staphylococcus aureus and Clostridium difficile on a glass surface and studied the impact on bacterial cells using atomic force microscopy (AFM). Both plasma types exhibited bactericidal effects on Staph. aureus (log3·6 - >log7), with increased activity against methicillin-resistant strains, but had a negligible effect on Cl. difficile spores (helium and helium-air plasma as a decontaminant and demonstrated a significant reduction in bacterial counts of Staphylococcus aureus on a glass surface. Atomic force microscopy morphologically confirmed the impact on bacterial cells. This approach warrants further study as an alternative to current options for hospital hygiene. © 2013 The Society for Applied Microbiology.

  19. Helium passage through homogeneous ultrafine hydrocarbon layers

    Directory of Open Access Journals (Sweden)

    Bubenchikov Michael A.

    2017-01-01

    Full Text Available The present paper deals with the problem of helium atoms and methane molecules moving through a hydrocarbon layer of evenly distributed energy sources. A computational technique for integrating the Schrödinger equation based on formulation of two fundamental numerical solutions to the problem of waves passing through a barrier is suggested. A linear combination of these solutions defines the required wave function, while cross-linking with asymptotic boundary conditions allows determining the coefficients of transmission and particle reflection from the potential layer barrier.

  20. Linde standard helium plant of medium capacity

    Energy Technology Data Exchange (ETDEWEB)

    Patzelt, A.; Stephan, A.; Nienaber, U.; Weber, J.

    1991-01-01

    The unit is designed to deliver up to 70 l/h of liquid helium (LHe) without precooling by liquid nitrogen (LN{sub 2}), up to 105 l/h with LN{sub 2} precooling, or up to 210 W cryo-refrigeration output at 4.5 K. Its principal components are an oil-flooded screw compressor, gas-bearing expansion turbines, vacuum-brazed aluminium plate-fin heat exchangers, an automatic feed gas purifier, and a process control system. Descriptions are given of the process layout, the main system components, and operation of the unit. (orig.).

  1. Heuristic theory of positron-helium scattering.

    Science.gov (United States)

    Drachman, R. J.

    1971-01-01

    An error in a previous modified adiabatic approximation (Drachman, 1966), due to a lack of generality in the form of the short-range correlation part of the wave function for L greater than zero, is corrected heuristically by allowing the monopole suppression parameter to depend on L. An L-dependent local potential is constructed to fit the well-known positron-hydrogen s, p, and d wave phase shifts below the rearrangement threshold. The same form of potential yields a positron-helium cross-section in agreement with a recent experimental measurement near threshold.

  2. Production of thorium-229 using helium nuclei

    Science.gov (United States)

    Mirzadeh, Saed [Knoxville, TN; Garland, Marc Alan [Knoxville, TN

    2010-12-14

    A method for producing .sup.229Th includes the steps of providing .sup.226Ra as a target material, and bombarding the target material with alpha particles, helium-3, or neutrons to form .sup.229Th. When neutrons are used, the neutrons preferably include an epithermal neutron flux of at least 1.times.10.sup.13 n s.sup.-1cm.sup.-2. .sup.228Ra can also be bombarded with thermal and/or energetic neutrons to result in a neutron capture reaction to form .sup.229Th. Using .sup.230Th as a target material, .sup.229Th can be formed using neutron, gamma ray, proton or deuteron bombardment.

  3. Variable helium diffusion characteristics in fluorite

    Science.gov (United States)

    Wolff, R.; Dunkl, I.; Kempe, U.; Stockli, D.; Wiedenbeck, M.; von Eynatten, H.

    2016-09-01

    Precise analysis of the diffusion characteristics of helium in fluorite is crucial for establishing the new fluorite (U-Th-Sm)/He thermochronometer (FHe), which potentially provides a powerful tool for dating ore deposits unsuitable for the application of conventional geochronometers. Incremental helium outgassing experiments performed on fluorites derived from a spectrum of geological environments suggest a thermally activated volume diffusion mechanism. The diffusion behaviour is highly variable and the parameters range between log D0/a2 = 0.30 ± 0.27-7.27 ± 0.46 s-1 and Ea = 96 ± 3.5-182 ± 3.8 kJ/mol. Despite the fact that the CaF2 content of natural fluorites in most cases exceeds 99 weight percent, the closure temperature (Tc) of the fluorite (U-Th-Sm)/He thermochronometer as calculated from these diffusion parameters varies between 46 ± 14 °C and 169 ± 9 °C, considering a 125 μm fragment size. Here we establish that minor substitutions of calcium by rare earth elements and yttrium (REE + Y) and related charge compensation by sodium, fluorine, oxygen and/or vacancies in the fluorite crystal lattice have a significant impact on the diffusivity of helium in the mineral. With increasing REE + Y concentrations F vacancies are reduced and key diffusion pathways are narrowed. Consequently, a higher closure temperature is to be expected. An empirical case study confirms this variability: two fluorite samples from the same deposit (Horni Krupka, Czech Republic) with ca. 170 °C and ca. 43 °C Tc yield highly different (U-Th-Sm)/He ages of 290 ± 10 Ma and 79 ± 10 Ma, respectively. Accordingly, the fluorite sample with the high Tc could have quantitatively retained helium since the formation of the fluorite-bearing ores in the Permian, despite subsequent Mesozoic burial and associated regional hydrothermal heating. In contrast, the fluorite with the low Tc yields a Late Cretaceous age close to the apatite fission track (AFT) and apatite (U-Th)/He ages (AHe

  4. Temperature rise in superfluid helium pumps

    Science.gov (United States)

    Kittel, Peter

    1988-01-01

    The temperature rise of a fountain effect pump (FEP) and of a centrifugal pump (CP) are compared. Calculations and estimates presented here show that under the operating conditions expected during the resupply of superfluid helium in space, a centrifugal pump will produce a smaller temperature rise than will a fountain effect pump. The temperature rise for the FEP is calculated assuming an ideal pump, while the temperature rise of the CP is estimated from the measured performance of a prototype pump. As a result of this smaller temperature rise and of the different operating characteristics of the two types of pumps, transfers will be more effective using a centrifugal pump.

  5. SIMULATION OF PULSED BREAKDOWN IN HELIUM BY ADAPTIVE METHODS

    Directory of Open Access Journals (Sweden)

    S. I. Eliseev

    2014-09-01

    Full Text Available The paper deals with the processes occurring during electrical breakdown in gases as well as numerical simulation of these processes using adaptive mesh refinement methods. Discharge between needle electrodes in helium at atmospheric pressure is selected for the test simulation. Physical model of the accompanying breakdown processes is based on self- consistent system of continuity equations for streams of charged particles (electrons and positive ions and Poisson equation for electric potential. Sharp plasma heterogeneity in the area of streamers requires the usage of adaptive algorithms for constructing of computational grids for modeling. The method for grid adaptive construction together with justification of its effectiveness for significantly unsteady gas breakdown simulation at atmospheric pressure is described. Upgraded version of Gerris package is used for numerical simulation of electrical gas breakdown. Software package, originally focused on solution of nonlinear problems in fluid dynamics, appears to be suitable for processes modeling in non-stationary plasma described by continuity equations. The usage of adaptive grids makes it possible to get an adequate numerical model for the breakdown development in the system of needle electrodes. Breakdown dynamics is illustrated by contour plots of electron densities and electric field intensity obtained in the course of solving. Breakdown mechanism of positive and negative (orientated to anode streamers formation is demonstrated and analyzed. Correspondence between adaptive building of computational grid and generated plasma gradients is shown. Obtained results can be used as a basis for full-scale numerical experiments on electric breakdown in gases.

  6. Study of ion-irradiated tungsten in deuterium plasma

    Energy Technology Data Exchange (ETDEWEB)

    Khripunov, B.I., E-mail: boris@nfi.kiae.ru [National Research Center Kurchatov Institute, Kurchatov Sq. 1, Moscow 123182 (Russian Federation); Gureev, V.M.; Koidan, V.S.; Kornienko, S.N.; Latushkin, S.T.; Petrov, V.B.; Ryazanov, A.I.; Semenov, E.V.; Stolyarova, V.G.; Danelyan, L.S. [National Research Center Kurchatov Institute, Kurchatov Sq. 1, Moscow 123182 (Russian Federation); Kulikauskas, V.S.; Zatekin, V.V. [Institute of Nuclear Physics, Lomonosov University, Moscow 119991 (Russian Federation); Unezhev, V.N. [National Research Center Kurchatov Institute, Kurchatov Sq. 1, Moscow 123182 (Russian Federation)

    2013-07-15

    Experimental study aimed at investigation of neutron induced damage influence on fusion reactor plasma facing materials is reported. Displacement damage was produced in tungsten by high-energy helium and carbon ions at 3–10 MeV. The reached level of displacement damage ranged from several dpa to 600 dpa. The properties of the irradiated tungsten were studied in steady-state deuterium plasma on the LENTA linear divertor simulator. Plasma exposures were made at 250 eV of ion energy to fluence 10{sup 21}–10{sup 22} ion/cm{sup 2}. Erosion dynamics of the damaged layer and deuterium retention were observed. Surface microstructure modifications and important damage of the 5 μm layer shown. Deuterium retention in helium-damaged tungsten (ERD) showed its complex behavior (increase or decrease) depending on implanted helium quantity and the structure of the surface layer.

  7. Turnkey Helium Purification and Liquefaction Plant for DARWIN, Australia

    Science.gov (United States)

    Lindemann, U.; Boeck, S.; Blum, L.; Kurtcuoglu, K.

    2010-04-01

    The Linde Group, through its Australian subsidiary BOC Limited, has signed an agreement with Darwin LNG Pty Ltd for the supply of feed-gas to Linde's new helium refining and liquefaction facility in Darwin, Australia. Linde Kryotechnik AG, located in Switzerland, has carried out the engineering and fabrication of the equipment for the turn key helium plant. The raw feed gas flow of 20'730 Nm3/h contains up to of 3 mol% helium. The purification process of the feed gas consists of partial condensation of nitrogen in two stages, cryogenic adsorption and finally catalytic oxidation of hydrogen followed by a dryer system. Downstream of the purification the refined helium is liquefied using a modified Bryton process and stored in a 30'000 gal LHe tank. For further distribution and export of the liquid helium there are two stations available for filling of truck trailers and containers. The liquid nitrogen, required for refrigeration capacity to the nitrogen removal stages in the purification process as well as for the pre-cooling of the pure helium in the liquefaction process, is generated on site during the feed gas purification process. The optimized process provides low power consumption, maximum helium recovery and a minimum helium loss.

  8. Thermal stability of helium-vacancy clusters in iron

    CERN Document Server

    Morishita, K; Wirth, B D; Díaz de la Rubia, T

    2003-01-01

    Molecular dynamics calculations were performed to evaluate the thermal stability of helium-vacancy clusters (He sub n V sub m) in Fe using the Ackland Finnis-Sinclair potential, the Wilson-Johnson potential and the Ziegler-Biersack-Littmark-Beck potential for describing the interactions of Fe-Fe, Fe-He and He-He, respectively. Both the calculated numbers of helium atoms, n, and vacancies, m, in clusters ranged from 0 to 20. The binding energies of an interstitial helium atom, an isolated vacancy and a self-interstitial iron atom to a helium-vacancy cluster were obtained from the calculated formation energies of clusters. All the binding energies do not depend much on cluster size, but they primarily depend on the helium-to-vacancy ratio (n/m) of clusters. The binding energy of a vacancy to a helium-vacancy cluster increases with the ratio, showing that helium increases cluster lifetime by dramatically reducing thermal vacancy emission. On the other hand, both the binding energies of a helium atom and an iron ...

  9. Proton-Helium Elastic Electromagnetic Cross-Section

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Burn [Chinese Academy of Sciences (CAS), Lanzhou (China); Ng, Kingyuen B. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2015-11-01

    In the test facility of the C-ADS project, A 25-MeV proton beam is directed to hit a target consisting of 1-mm tungsten balls lubricated by 100-Pa helium gas. To estimate the power loss to the helium gas, an accurate collision cross section is computed.

  10. Low Temperature Gaseous Helium and very High Turbulence Experiments

    CERN Document Server

    Pietropinto, S; Castaing, B; Chabaud, B; Gagne, Y; Hébral, B; Ladam, Y; Lebrun, P; Pirotte, O; Poulain, C; Roche, P E

    2002-01-01

    Cryogenic gaseous helium gives access to extreme turbulent experimental conditions. The very high cooling helium flow rates available at CERN have been used to reach Reynolds numbers up to Re ~ 10**7 in a round jet experiment. First results are discussed.

  11. Search for Dislocation Free Helium 4 Crystals.

    Science.gov (United States)

    Souris, F; Fefferman, A D; Haziot, A; Garroum, N; Beamish, J R; Balibar, S

    The giant plasticity of [Formula: see text]He crystals has been explained as a consequence of the large mobility of their dislocations. Thus, the mechanical properties of dislocation free crystals should be quite different from those of usual ones. In 1996-1998, Ruutu et al. published crystal growth studies showing that, in their helium 4 crystals, the density of screw dislocations along the c-axis was less than 100 per cm[Formula: see text], sometimes zero. We have grown helium 4 crystals using similar growth speeds and temperatures, and extracted their dislocation density from their mechanical properties. We found dislocation densities that are in the range of 10[Formula: see text]-10[Formula: see text] per cm[Formula: see text], that is several orders of magnitude larger than Ruutu et al. Our tentative interpretation of this apparent contradiction is that the two types of measurements are somewhat indirect and concern different types of dislocations. As for the dislocation nucleation mechanism, it remains to be understood.

  12. Helium enrichment during convective carbon dioxide dissolution

    Science.gov (United States)

    Larson, T.; Hesse, M. A.

    2013-12-01

    Motivated by observed variations of the CO2/He ratios in natural carbon dioxide (CO2) reservoirs, such as the Bravo Dome field in northeastern New Mexico, we have performed laboratory experiments equilibrating gas mixtures containing Helium (He) and CO2 with water, at close to ambient conditions in a closed system. The experimental design allows for continuous measurement of headspace pressure as well as timed interval measurements of the CO2/He ratios and the δ13C value of CO2 in the headspace. Results from three dissolution experiments are reported: 1) pure Helium system, 2) 98% CO2 + 2% Nitrogen system, and 3) 97% CO2 and 3% Helium. Final equilibrated experimental results are compared to theoretical results obtained using Henry's Law relationships. The evolution of the amount of dissolved CO2 computed from gas pressure and gas compositions are in good agreement with Henry's Law relationships. For example, the CO2 + N2 system was initially pressurized with pure CO2 to 1323 mbar and after six days it equilibrated to a measured headspace pressure of 596 mbar. This compares very well with a calculated equilibrium headspace pressure of 592 mbar for this system. The CO2 + He system was pressurized to 1398 mbar CO2 and after six days equilibrated to a measured headspace pressure of 397 mbar. This measured pressure is slightly higher than the predicted equilibrated headspace pressure of 341 mbar, indicating a possible leak in the system during this particular experiment. In both experiments the initial pH of the water was 9.3 and the final equilibrated pH was 5.4. The δ13C value of equilibrated headspace CO2 was within 0.25‰ of its starting δ13C value, demonstrating insignificant carbon isotope fractionation at low pH. Measured Helium/ CO2 ratios throughout the CO2+Helium experiment preserve a non-linear trend of increasing He/ CO2 ratios through time that correlate very well with the measured pressure drop from CO2 dissolution. This indicates that gas composition

  13. Helium Pressure Shift of the Hyperfine Clock Transition in Hg-201(+)

    Science.gov (United States)

    Larigani, S. Taghavi; Burt, E. A.; Tjoelker, R. L.

    2010-01-01

    There are two stable odd isotopes of mercury with singly ionized hyperfine structure suitable for a microwave atomic clock: Hg-199(+) and Hg-201(+). We are investigating the viability of a trapped ion clock based on Hg-201(+) in a configuration that uses a buffer gas to increase ion loading efficiency and counter ion heating from rf trapping fields. Traditionally, either helium or neon is used as the buffer gas at approx. 10(exp -5) torr to confine mercury ions near room temperature. In addition to the buffer gas, other residual background gasses such as H2O, N2, O2, CO, CO2, and CH2 may be present in trace quantities. Collisions between trapped ions and buffer gas or background gas atoms/molecules produce a momentary shift of the ion clock transition frequency and constitute one of the largest systematic effects in this type of clock. Here we report an initial measurement of the He pressure shift in Hg-201(+) and compare this to Hg-199(+).

  14. Binary helium dwarf supernovae. [numerical hydrodynamic investigation of evolution

    Science.gov (United States)

    Mazurek, T. J.

    1973-01-01

    The possibility of helium dwarf evolution to sufficiently high densities for violent helium ignition in low-massed binary systems is investigated. During accretional evolution the occurrence of thermonuclear runaway is found to be probable when the dwarf's mass approaches 1 solar mass, and steady-state discontinuous wave propagation considerations indicate that the dwarf is totally incinerated (i.e., its total mass burns to nuclear equilibrium) by a detonation wave. A numerical stellar dynamic investigation, including the full effects of nuclear statistical equilibrium and electron capture indicates total disruption for all reasonable dwarf central densities. For consistency with the cosmic element abundances, the conclusion of total disruption requires a low frequency for helium supernova events, implying that helium ignition in mass-exchanging binaries must occur at the lower densities of the relatively mild helium flash.

  15. The role of radiation damage on retention and temperature intervals of helium and hydrogen detrapping in structural materials

    Energy Technology Data Exchange (ETDEWEB)

    Tolstolutskaya, G.D., E-mail: g.d.t@kipt.kharkov.ua [National Science Center “Kharkov Institute of Physics and Technology”, 1, Akademicheskaya St., 61108 Kharkov (Ukraine); Ruzhytskyi, V.V.; Voyevodin, V.N.; Kopanets, I.E.; Karpov, S.A.; Nikitin, A.V. [National Science Center “Kharkov Institute of Physics and Technology”, 1, Akademicheskaya St., 61108 Kharkov (Ukraine)

    2013-11-15

    An experimental study of hydrogen/deuterium behavior in ferritic–martensitic stainless steels EP-450 (Cr13Mo2NbVB), EP-852 (Cr13Mo2VS), and RUSFER-EK-181 (Fe12Cr2WVTaB) is presented. The effect of displacement damage (dpa) resulting from irradiation with helium, hydrogen, and argon ions on features of deuterium detrapping and retention in steels was studied using ion implantation, nuclear reaction depth profiling, and thermal desorption spectrometry techniques. Numerical simulation on the basis of the continuum rate theory was applied for obtaining thermodynamic parameters of deuterium trapping and desorption in steels.

  16. Using Uncertainty Principle to Find the Ground-State Energy of the Helium and a Helium-like Hookean Atom

    Science.gov (United States)

    Harbola, Varun

    2011-01-01

    In this paper, we accurately estimate the ground-state energy and the atomic radius of the helium atom and a helium-like Hookean atom by employing the uncertainty principle in conjunction with the variational approach. We show that with the use of the uncertainty principle, electrons are found to be spread over a radial region, giving an electron…

  17. Electromagnetic ion cyclotron waves in the helium branch induced by multiple electromagnetic ion cyclotron triggered emissions

    Czech Academy of Sciences Publication Activity Database

    Shoji, M.; Omura, Y.; Grison, Benjamin; Pickett, J.; Dandouras, I.; Engebretson, M.

    2011-01-01

    Roč. 38, - (2011), L17102/1-L17102/5 ISSN 0094-8276 R&D Projects: GA ČR(CZ) GPP209/11/P848 Institutional research plan: CEZ:AV0Z30420517 Keywords : 1-2 MAGNETIC PULSATIONS * EQUATORIAL MAGNETOSPHERE * DISTRIBUTIONS * STORMS Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 3.792, year: 2011 http://www.agu.org/pubs/crossref/2011/2011GL048427.shtml

  18. Evaluation of irradiation hardening and microstructure evolution under the synergistic interaction of He and subsequent Fe ions irradiation in CLAM steel

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Y.P.; Liu, P.P.; Zhu, Y.M.; Wang, Z.Q.; Wan, F.R.; Zhan, Q., E-mail: qzhan@mater.ustb.edu.cn

    2016-08-15

    Sequential dual-ion irradiation is a useful technique for experimental exploration on the synergistic effects of ion accumulation and cascade damage. In this research, the helium-ion accumulation concomitant with displacement damage induced by helium and iron ions irradiation in China low active martensitic (CLAM) steel was studied by ion-irradiation, transmission electron microscopy and nano-indentation technique. The helium bubbles formed under continuous implantation of helium ions at room temperature and the helium dose forming observed bubbles resolved by TEM clearly in CLAM steel is around 0.7 × 10{sup 17}–1.0 × 10{sup 17} He{sup +}/cm{sup 2} under single 100 keV He{sup +} irradiation. Significant irradiation hardening was observed in the samples with various ion- and dose-irradiations. Positive correlation between the hardening increment and the helium-ion dose has been established in single helium-ion irradiated samples. On the other hand, the subsequent Fe-ion irradiation greatly promoted the formation and growth of helium bubbles as well as dislocation loops in sequential dual-ion irradiated samples. No significant contribution of the subsequent Fe-ion irradiation on the hardness increment was found for the sequential dual-ion irradiated samples. It is suggested that the defects recombination, the combination effects of size and density of defects contribute to the degree of irradiation hardening. The calculated hardness increment based on dispersion strengthening model and the experimental microstructure analysis followed the same trend as the experimental nano-indentation data. - Highlights: • Sequential dual-ion irradiation was used to study the synergistic effects of helium accumulation and cascade damage. • The critical helium dose for notable growth of bubbles is around 1.0 × 10{sup 17} He{sup +}/cm{sup 2}. • Bubbles and dislocation loops grew greatly after subsequent Fe-ions irradiation. • The tested and calculated hardness increments

  19. Surface and internal microstructure damage of He-ion-irradiated CLAM steel studied by cross-sectional transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, P.P. [School of Material Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); School of Metallurgical and Ecological Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Zhan, Q., E-mail: qzhan@mater.ustb.edu.cn [School of Material Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Fu, Z.Y.; Wei, Y.P. [School of Material Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Wang, Y.M. [Faculty of Engineering, Hokkaido University, Sapporo 060-8628 (Japan); Wang, F.M. [School of Metallurgical and Ecological Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Ohnuki, S. [Faculty of Engineering, Hokkaido University, Sapporo 060-8628 (Japan); Wan, F.R. [School of Material Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China)

    2015-11-15

    Good understanding of blistering and embrittlement mechanism depends on good investigation of surface and internal microstructure damage of gas-ion-irradiated materials. Internal and surface microstructure of He{sup +} ion irradiated CLAM steel were examined by cross-sectional transmission electron microscopy combining focused ion beam. Variation of helium bubble density and size distribution versus depth in CLAM steel after high dose helium irradiation at room temperature was investigated. The average size of helium bubble increased within 100–400 nm but decreased near the non-irradiated matrix with the increase of depth, while the density followed a reverse trend. The formation and growth mechanism of helium bubble is different at different irradiation depth. The formation of a zone of large bubbles under the surface is the main reason of surface blistering and flaking. Helium induced irradiation swelling and surface blistering at low temperature were also discussed. - Highlights: • Microstructure of helium irradiated CLAM steel was investigated by FIB and TEM. • The nucleation of helium bubble was controlled by both different mechanisms. • The substructure of surface blisters has been analyzed in detail by XTEM. • Helium induced surface blistering and irradiation swelling have been discussed.

  20. Helium processing for deuterium/helium burns in ITER's physics phase

    Energy Technology Data Exchange (ETDEWEB)

    Finn, P.A.; Sze, D.K.

    1991-01-01

    The requirements for vacuum pumping and fuel processing for deuterium/helium (D/{sup 3}He) burns in the physics operating phase for the International Thermonuclear Experimental Reactor (ITER) were assessed. These burns are expected to have low fusion power (100 MW), short burn times ({le}30 s), limited operation (2000 shots), and a fractional burn {approximately}0.3%. For the physics phase, the fuel processing system will include several units to separate deuterium and helium (activated charcoal bed, SAES getter and a Pd/Ag diffuser), as well as an isotopic separation system to separate {sup 3}He and {sup 4}He. The needed vacuum system's cryosorption surface area may be as large as 10 m{sup 2} if the burn time is {approximately}200 s, the fractional burn is <0.3%, or the fusion power is >100 MW. 8 refs., 1 fig., 4 tabs.

  1. Effect of helium implantation on mechanical properties of EUROFER97 evaluated by nanoindentation

    Energy Technology Data Exchange (ETDEWEB)

    Roldán, M., E-mail: marcelo.roldan@ciemat.es [National Fusion Laboratory-CIEMAT. Avda. Complutense 40, 28040 Madrid (Spain); Fernández, P. [National Fusion Laboratory-CIEMAT. Avda. Complutense 40, 28040 Madrid (Spain); Rams, J. [Rey Juan Carlos University, C/Tulipán s/n, Móstoles, 28933 Madrid (Spain); Jiménez-Rey, D. [Centre for Micro-Analysis of Materials (CMAM, UAM), C/Faraday 3, 28049 Madrid (Spain); Ortiz, C.J.; Vila, R. [National Fusion Laboratory-CIEMAT. Avda. Complutense 40, 28040 Madrid (Spain)

    2014-05-01

    Helium effects on EUROFER97 mechanical properties were studied by means of nanoindentation. The steel was implanted with He ions in a stair-like profile configuration using energies from 2 to 15 MeV at room temperature. Firstly, a deep nanoindentation study was carried out on as-received state (normalized + tempered) in order to obtain a reliable properties database at the nanometric scale, including aspects such as indentation size effect. The nanoindentation hardness of tests on He implanted samples showed a hardness increase depending on the He concentration. The hardness increase follows the He implantation concentration profile with a good accuracy according to BCA calculations using MARLOWE code, considering the whole volume affected by the nanoindentation tests. The results obtained in this work shown that nanoindentation technique permits to assess any change of hardness properties due to ion implantation.

  2. An alpha particle measurement system using an energetic neutral helium beam in ITER (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Sasao, M.; Tanaka, N.; Terai, K.; Kaneko, O. [Graduate school of Engineering, Tohoku University, Sendai 980-8579 (Japan); Kisaki, M.; Kobuchi, T.; Tsumori, K.; Okamoto, A.; Kitajima, S. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Shinto, K. [IFMIF R and D Center, Japan Atomic Energy Agency, Rokkasho, Aomori 039-3212 (Japan); Wada, M. [Graduate School of Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321 (Japan)

    2012-02-15

    An energetic helium neutral beam is involved in the beam neutralization measurement system of alpha particles confined in a DT fusion plasma. A full size strong-focusing He{sup +} ion source (2 A, the beam radius of 11.3 mm, the beam energy less than 20 keV). Present strong-focusing He{sup +} ion source shows an emittance diagram separated for each beamlet of multiple apertures without phase space mixing, despite the space charge of a beamlet is asymmetric and the beam flow is non-laminar. The emittance of beamlets in the peripheral region was larger than that of center. The heat load to the plasma electrode was studied to estimate the duty factor for the ITER application.

  3. Mutation induced with ion beam irradiation in rose

    Science.gov (United States)

    Yamaguchi, H.; Nagatomi, S.; Morishita, T.; Degi, K.; Tanaka, A.; Shikazono, N.; Hase, Y.

    2003-05-01

    The effects of mutation induction by ion beam irradiation on axillary buds in rose were investigated. Axillary buds were irradiated with carbon and helium ion beams, and the solid mutants emerged after irradiation by repeated cutting back. In helium ion irradiation, mutations were observed in plants derived from 9 buds among 56 irradiated buds in 'Orange Rosamini' and in plants derived from 10 buds among 61 irradiated buds in 'Red Minimo'. In carbon ion, mutations were observed in plants derived from 12 buds among 88 irradiated buds in 'Orange Rosamini'. Mutations were induced not only in higher doses but also in lower doses, with which physiological effect by irradiation was hardly observed. Irradiation with both ion beams induced mutants in the number of petals, in flower size, in flower shape and in flower color in each cultivar.

  4. Mutation induced with ion beam irradiation in rose

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, H. E-mail: yhiroya@nias.affrc.go.jp; Nagatomi, S.; Morishita, T.; Degi, K.; Tanaka, A.; Shikazono, N.; Hase, Y

    2003-05-01

    The effects of mutation induction by ion beam irradiation on axillary buds in rose were investigated. Axillary buds were irradiated with carbon and helium ion beams, and the solid mutants emerged after irradiation by repeated cutting back. In helium ion irradiation, mutations were observed in plants derived from 9 buds among 56 irradiated buds in 'Orange Rosamini' and in plants derived from 10 buds among 61 irradiated buds in 'Red Minimo'. In carbon ion, mutations were observed in plants derived from 12 buds among 88 irradiated buds in 'Orange Rosamini'. Mutations were induced not only in higher doses but also in lower doses, with which physiological effect by irradiation was hardly observed. Irradiation with both ion beams induced mutants in the number of petals, in flower size, in flower shape and in flower color in each cultivar.

  5. Helium and Sulfur Hexafluoride in Musical Instruments

    Science.gov (United States)

    Forinash, Kyle; Dixon, Cory L.

    2014-11-01

    The effects of inhaled helium on the human voice were investigated in a recent article in The Physics Teacher.1 As mentioned in that article, demonstrations of the effect are a popular classroom activity. If the number of YouTube videos is any indication, the effects of sulfur hexafluoride on the human voice are equally popular. However, there appears to be little information available on the effects of either of these gases on musical instruments.2 We describe here the results of a student project that involved measuring the frequency shifts in an organ pipe, a trumpet, and a trombone as the result of filling the instruments with these two gases. The project was one of several possible end-of-semester projects required in an elective science of sound course for non-science majors.

  6. Frequency metrology in quantum degenerate helium

    Directory of Open Access Journals (Sweden)

    Vassen Wim

    2013-08-01

    Full Text Available We have measured the absolute frequency of the 1557-nm doubly forbidden transition between the two metastable states of helium, 2 3S1 (lifetime 8000 s and 2 1S0 (lifetime 20 ms, with 1 kHz precision. With an Einstein coefficient of 10−7 s−1 this is one of weakest optical transitions ever measured. The measurement was performed in a Bose-Einstein condensate of 4He* as well as in a Degenerate Fermi Gas of 3He*, trapped in a crossed dipole trap. From the isotope shift we deduced the nuclear charge radius difference between the α-particle and the helion. Our value differs by 4σ with a very recent result obtained on the 2 3S → 2 3P transition.

  7. An Update of the Primordial Helium Abundance

    Science.gov (United States)

    Peimbert, Antonio; Peimbert, Manuel; Luridiana, Valentina

    2015-08-01

    Three of the best determinations of the primordial helium abundance (Yp) are those obtained from low metallicity HII regions by Aver, Olive, Porter, & Skillman (2013); Izotov, Thuan, & Guseva (2014); and Peimbert, Peimbert, & Luridiana (2007). In this poster we update the Yp determination by Peimbert et al. taking into account, among other aspects, recent advances in the determination of the He atomic physical parameters, the temperature structure, the collisional effects of high temperatures on the Balmer lines, as well as the effect of H and He bound-bound absorption.We compare our results with those of Aver et al. and Izotov et al. and point out possible explanations for the differences among the three determinations. We also compare our results with those obtained with the Plank satellite considering recent measurements of the neutron mean life; this comparison has implications on the determination of the number of light neutrino families.

  8. Cluster counting in helium based gas mixtures

    Science.gov (United States)

    Cataldi, G.; Grancagnolo, F.; Spagnolo, S.

    1997-02-01

    The statistical advantages deriving from counting primary ionization, as opposed to the conventional energy loss measurement, are extensively discussed. A primary ionization counting method is proposed for a "traditional", cylindrical, single sense wire cell drift chamber, which makes use of a helium based gas mixture. Its conceptual feasibility is proven by means of a simple Monte Carlo simulation. A counting algorithm is developed and tested on the simulation output. A definition of the parameters of the read-out and of the digitizing electronics is given, assuming the described counting algorithm applied to a general detector design, in order to have a complete and realistic planning of a cluster counting measurement. Finally, some interesting results from a beam test, performed according to the described parameters, on primary ionization measurements and on {π}/{μ} separation are shown.

  9. Helium Inventory Management For LHC Cryogenics

    CERN Document Server

    Pyarali, Maisam

    2017-01-01

    The LHC is a 26.7 km circumference ring lined with superconducting magnets that operate at 1.9 K. These magnets are used to control the trajectory of beams of protons traveling in opposite directions and collide them at various experimental sites across the LHC where their debris is analyzed. The focus of this paper is the cryogenic system that allows the magnets to operate in their superconducting states. It aims to highlight the operating principles of helium refrigeration and liquefaction, with and without nitrogen pre-cooling; discuss the various refrigerators and liquefiers used at CERN for both LHC and Non-LHC applications, with their liquefaction capacities and purposes; and finally to deliberate the management of the LHC inventory and how it contributes to the strategic decision CERN makes regarding the inventory management during the Year-End Technical Stop (YETS), Extended Year-End Technical Stop (EYETS) and long shutdowns.

  10. Positronium and Electron Scattering on Helium

    Science.gov (United States)

    DiRienzi, Joseph

    2011-01-01

    A recent work [1] establishes experimentally that Positronium scattering by atoms of various elements is surprisingly close in total cross-section to that of an isolated electron of the same velocity. In this work we will look at the scattering of Ps on Helium and compare it to a determination of the scattering of an e- with the same element. For both the Ps scattering and the e- scattering on He, we assume the symmetrization of the e- with the closed shell He electrons is the dominant interaction. A local effective potential employed in [2] and [3] is used to model the electron exchange and cross- sections are determined for a set of partial waves. For the Ps scattering we include as a secondary effect the Van der Waals interaction. For single e- scattering of He, we also employ a short range Coulomb potential and dispersion as contributing effects. Results of the cross-sections determined in each case are then compared

  11. Observation of the antimatter helium-4 nucleus.

    Science.gov (United States)

    2011-05-19

    High-energy nuclear collisions create an energy density similar to that of the Universe microseconds after the Big Bang; in both cases, matter and antimatter are formed with comparable abundance. However, the relatively short-lived expansion in nuclear collisions allows antimatter to decouple quickly from matter, and avoid annihilation. Thus, a high-energy accelerator of heavy nuclei provides an efficient means of producing and studying antimatter. The antimatter helium-4 nucleus (4He), also known as the anti-α (α), consists of two antiprotons and two antineutrons (baryon number B = -4). It has not been observed previously, although the α-particle was identified a century ago by Rutherford and is present in cosmic radiation at the ten per cent level. Antimatter nuclei with B antimatter nuclei and a benchmark for possible future observations of 4He in cosmic radiation.

  12. On the origins of trapped helium, neon and argon isotopic variations in meteorites. I - Gas-rich meteorites, lunar soil and breccia. II - Carbonaceous meteorites.

    Science.gov (United States)

    Black, D. C.

    1972-01-01

    Data are presented from stepwise heating experiments and total extractions on five meteorites: Kapoeta, Fayetteville, Holman Island, Cee Vee, and Pultusk. These data reveal the presence of four isotopically distinct trapped neon components. A comparison of trapped neon with trapped helium and argon in bulk analyses indicates the existence of correlated helium, neon and argon isotopic structures. Component B is attributed primarily to direct implantation of rare gas ions by the present day solar wind. Component C is identified with directly implanted low energy (1-10 Mev/n) solar flare rare gases. Component D is associated with rare gas ions implanted in meteoritic material by the primitive, pre-main sequence, solar wind. A fourth component, observed only in Kapoeta and the lunar fines and breccia, is tentatively attributed to parent body 'atmospheric' ions implanted in surface material by a solar wind induced electric field.

  13. Liquid Oxygen Thermodynamic Vent System Testing with Helium Pressurization

    Science.gov (United States)

    VanDresar, Neil T.

    2014-01-01

    This report presents the results of several thermodynamic vent system (TVS) tests with liquid oxygen plus a test with liquid nitrogen. In all tests, the liquid was heated above its normal boiling point to 111 K for oxygen and 100 K for nitrogen. The elevated temperature was representative of tank conditions for a candidate lunar lander ascent stage. An initial test series was conducted with saturated oxygen liquid and vapor at 0.6 MPa. The initial series was followed by tests where the test tank was pressurized with gaseous helium to 1.4 to 1.6 MPa. For these tests, the helium mole fraction in the ullage was quite high, about 0.57 to 0.62. TVS behavior is different when helium is present than when helium is absent. The tank pressure becomes the sum of the vapor pressure and the partial pressure of helium. Therefore, tank pressure depends not only on temperature, as is the case for a pure liquid-vapor system, but also on helium density (i.e., the mass of helium divided by the ullage volume). Thus, properly controlling TVS operation is more challenging with helium pressurization than without helium pressurization. When helium was present, the liquid temperature would rise with each successive TVS cycle if tank pressure was kept within a constant control band. Alternatively, if the liquid temperature was maintained within a constant TVS control band, the tank pressure would drop with each TVS cycle. The final test series, which was conducted with liquid nitrogen pressurized with helium, demonstrated simultaneous pressure and temperature control during TVS operation. The simultaneous control was achieved by systematic injection of additional helium during each TVS cycle. Adding helium maintained the helium partial pressure as the liquid volume decreased because of TVS operation. The TVS demonstrations with liquid oxygen pressurized with helium were conducted with three different fluid-mixer configurations-a submerged axial jet mixer, a pair of spray hoops in the tank

  14. The primordial helium abundance from updated emissivities

    Energy Technology Data Exchange (ETDEWEB)

    Aver, Erik [Department of Physics, Gonzaga University, 502 E Boone Ave, Spokane, WA, 99258 (United States); Olive, Keith A.; Skillman, Evan D. [School of Physics and Astronomy, University of Minnesota, 116 Church St. SE, Minneapolis, MN, 55455 (United States); Porter, R.L., E-mail: aver@gonzaga.edu, E-mail: olive@umn.edu, E-mail: ryanlporter@gmail.com, E-mail: skillman@astro.umn.edu [Department of Physics and Astronomy, University of Georgia, Athens, GA, 30602 (United States)

    2013-11-01

    Observations of metal-poor extragalactic H II regions allow the determination of the primordial helium abundance, Y{sub p}. The He I emissivities are the foundation of the model of the H II region's emission. Porter, Ferland, Storey, and Detisch (2012) have recently published updated He I emissivities based on improved photoionization cross-sections. We incorporate these new atomic data and update our recent Markov Chain Monte Carlo analysis of the dataset published by Izotov, Thuan, and Stasi'nska (2007). As before, cuts are made to promote quality and reliability, and only solutions which fit the data within 95% confidence level are used to determine the primordial He abundance. The previously qualifying dataset is almost entirely retained and with strong concordance between the physical parameters. Overall, an upward bias from the new emissivities leads to a decrease in Y{sub p}. In addition, we find a general trend to larger uncertainties in individual objects (due to changes in the emissivities) and an increased variance (due to additional objects included). From a regression to zero metallicity, we determine Y{sub p} = 0.2465 ± 0.0097, in good agreement with the BBN result, Y{sub p} = 0.2485 ± 0.0002, based on the Planck determination of the baryon density. In the future, a better understanding of why a large fraction of spectra are not well fit by the model will be crucial to achieving an increase in the precision of the primordial helium abundance determination.

  15. Suicidal asphyxiation with helium: report of three cases.

    Science.gov (United States)

    Grassberger, Martin; Krauskopf, Astrid

    2007-01-01

    Helium is an inert gas that among other things is used medically to alleviate the symptoms of airway obstruction, as part of a diving mix in deep-sea diving or as balloon gas. In recent years the so-called right-to-die literature has suggested suffocation with inhaled helium as an effective and peaceful means of self-deliverance for terminally ill patients. Helium displaces oxygen and carbon dioxide and can thus lead to asphyxia. We report three cases of suicidal asphyxiation with helium gas that were examined at the Department of Forensic Medicine Vienna within three months in 2006. In all three cases, autopsy was unrewarding from the point of view of gross pathology. Special autopsy techniques and devices are required for collection of the gas from the lungs. Gas-chromatography is used to examine the gas for helium; however, this requires replacement of the carrier gas, which is itself usually helium. The fact that three people in Vienna committed suicide using this method within a short period of time, together with the abundance of detailed how-to literature on the Internet, suggests a possible future increase in the number of deaths associated with the inhalation of inert gases, particularly helium. Because of the diagnostic obstacles involved, it is necessary to rely on good death-scene investigation for situational evidence when the body is discovered.

  16. Toxicological findings in three cases of suicidal asphyxiation with helium.

    Science.gov (United States)

    Oosting, Roelof; van der Hulst, Rogier; Peschier, Leo; Verschraagen, Miranda

    2015-11-01

    Toxicological findings in deaths by asphyxiation due to a pure inert gas like helium are rare. We present three suicide cases of asphyxial death attributed to anoxia caused by inhalation of helium in a plastic bag positioned over the head. In one case, lung tissue, brain tissue and heart blood were obtained during standard autopsy procedures. In two cases, samples were obtained differently: heart blood, femoral blood, brain tissue, lung tissue and/or air from the lungs were directly sealed into headspace vials during autopsy. Air from the lungs was collected using a syringe and transferred into an aluminum gas sampling bag which was heat sealed as soon as possible. Semi-quantitative gas analyses were performed using headspace gas chromatography-thermal conductivity detection (HS-GC/TCD) with a molsieve column capable of separating permanent gasses. Nitrogen was used as carrier gas. In the first case no helium was detected in lung tissue, brain tissue and heart blood. In the second case the presence of helium was detected in lung tissue (approximately 5% helium in gaseous phase) but not in femoral blood. In the third case the presence of helium was detected in air from the lungs (0.05%), lung tissue (0.4%), brain tissue (0.1%) and heart blood (0.04%). Helium is easily lost if sampling is not performed properly. The presented cases suggest that quick sample collection of various matrices during autopsy is suitable to detect gasses like helium in postmortem cases. Use of HS-GC/TCD enables to detect an inert gas like helium. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Performance of Oil-Injected Scroll Compressors for Helium Refrigerators

    Science.gov (United States)

    Shiibayashi, Masao; Izunaga, Yasushi; Sado, Shintaro

    In recent years there arises growing demand of helium liquefaction refrigerators for the magnetic resonance imaging systems, magnetically levitated vehicles and other systems using superconducting magnet. From this background, a small size, scroll type of hermetic helium compressor capable of compressing helium gas to the pressure ratio of 20 in a single stage is developed. Main features of this compressor are as follows. 1) Discharge capacity can be varied from 7 to 20 Nm3/h by changing driving motor frequency from 30 to 80 Hz. 2) The overall adiabatic efficiency showed 72%∼79% under the pressure ratio range of 11∼20 at 60 Hz using oil injection cooling device.

  18. European standardization activities on safety of liquid helium cryostats

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    This talk gives a general overview on the challenges of designing safety units for liquid helium cryostats with regard to existing industry standards. It reviews the work of a national working group that published the technical guideline DIN SPEC 4683 in April 2015, which is dedicated to the particular conditions in liquid helium cryostats. Based on both this guideline and equivalent documents from e.g. CEA, CERN, a working group is being formed at the European Committee for Standardization, associated to CEN/TC 268, which will work on a European standard on safety of liquid helium cryostats. The actual status and the schedule of this project are presented.

  19. International thermodynamic tables of the fluid state helium-4

    CERN Document Server

    Angus, S; McCarty, R D

    2013-01-01

    International Thermodynamic Tables of the Fluid State Helium-4 presents the IUPAC Thermodynamic Tables for the thermodynamic properties of helium. The IUPAC Thermodynamic Tables Project has therefore encouraged the critical analysis of the available thermodynamic measurements for helium and their synthesis into tables. This book is divided into three chapters. The first chapter discusses the experimental results and compares with the equations used to generate the tables. These equations are supplemented by a vapor pressure equation, which represents the 1958 He-4 scale of temperature that is

  20. Multi-objective Optimization on Helium Liquefier Using Genetic Algorithm

    Science.gov (United States)

    Wang, H. R.; Xiong, L. Y.; Peng, N.; Meng, Y. R.; Liu, L. Q.

    2017-02-01

    Research on optimization of helium liquefier is limited at home and abroad, and most of the optimization is single-objective based on Collins cycle. In this paper, a multi-objective optimization is conducted using genetic algorithm (GA) on the 40 L/h helium liquefier developed by Technical Institute of Physics and Chemistry of the Chinese Academy of Science (TIPC, CAS), steady solutions are obtained in the end. In addition, the exergy loss of the optimized system is studied in the case of with and without liquid nitrogen pre-cooling. The results have guiding significance for the future design of large helium liquefier.

  1. Non-local Thermodynamic Equilibrium Abundance Analyses of the Extreme Helium Stars V652 Her and HD 144941

    Science.gov (United States)

    Pandey, Gajendra; Lambert, David L.

    2017-10-01

    Optical high-resolution spectra of V652 Her and HD 144941, the two extreme helium stars with exceptionally low C/He ratios, have been subjected to a non-LTE abundance analysis using the tools TLUSTY and SYNSPEC. Defining atmospheric parameters were obtained from a grid of non-LTE atmospheres and a variety of spectroscopic indicators including He I and He II line profiles, and the ionization equilibrium of ion pairs such as C II/C III and N II/N III. The various indicators provide a consistent set of atmospheric parameters: T eff = 25,000 ± 300 K, log g = 3.10 ± 0.12(cgs), and ξ = 13 ± 2 km s-1 are provided for V652 Her, and T eff = 22,000 ± 600 K, log g = 3.45 ± 0.15 (cgs), and ξ = 10 km s-1 are provided for HD 144941. In contrast to the non-LTE analyses, the LTE analyses—LTE atmospheres and an LTE line analysis—with the available indicators do not provide a consistent set of atmospheric parameters. The principal non-LTE effect on the elemental abundances is on the neon abundance. It is generally considered that these extreme helium stars with their very low C/He ratio result from the merger of two helium white dwarfs. Indeed, the derived composition of V652 Her is in excellent agreement with predictions by Zhang & Jeffery, who model the slow merger of helium white dwarfs; a slow merger results in the merged star having the composition of the accreted white dwarf. In the case of HD 144941, which appears to have evolved from metal-poor stars, a slow merger is incompatible with the observed composition but variations of the merger rate may account for the observed composition. More detailed theoretical studies of the merger of a pair of helium white dwarfs are to be encouraged.

  2. New experimental device for VHTR structural material testing and helium coolant chemistry investigation - High Temperature Helium Loop in NRI Rez

    Energy Technology Data Exchange (ETDEWEB)

    Berka, Jan, E-mail: bej@cvrez.cz [Research Centre Rez, Ltd, Husinec-Rez 130, 25068 Rez (Czech Republic); Institute of Chemical Technology Prague, Technicka 1905, 16628 Prague 6 (Czech Republic); Matecha, Josef, E-mail: josef.matecha@ujv.cz [Nuclear Research Institute Rez plc., Husinec-Rez 130, 25068 Rez (Czech Republic); Cerny, Michal [Institute of Chemical Technology Prague, Technicka 1905, 16628 Prague 6 (Czech Republic); Viden, Ivan, E-mail: ivan.viden@vscht.cz [Institute of Chemical Technology Prague, Technicka 1905, 16628 Prague 6 (Czech Republic); Sus, Frantisek [Research Centre Rez, Ltd, Husinec-Rez 130, 25068 Rez (Czech Republic); Nuclear Research Institute Rez plc., Husinec-Rez 130, 25068 Rez (Czech Republic); Hajek, Petr [Nuclear Research Institute Rez plc., Husinec-Rez 130, 25068 Rez (Czech Republic)

    2012-10-15

    The High Temperature Helium Loop (HTHL) is an experimental device for simulation of VHTR helium coolant conditions. The purpose of the HTHL is structural materials testing and helium coolant chemistry investigation. In the HTHL pure helium will be used as working medium and its main physical parameters are 7 MPa, max. temperature in the test section 900 Degree-Sign C and flow rate 37.8 kg/h. The HTHL consists of an active channel, the helium purification system, the system of impurities dosage (e.g. CO, CO{sub 2}, H{sub 2}, H{sub 2}O, O{sub 2}, N{sub 2}, and CH{sub 4}) and the helium chemistry monitoring system (sampling and on-line analysis and determination of impurities in the helium flow). The active channel is planned to be placed into the core of the experimental reactor LVR-15 which will serve as a neutron flux source (max. 2.5 Multiplication-Sign 10{sup 18} n/m{sup 2} s for fast neutrons). The HTHL is now under construction. Some of its main parts are finished, some are still being produced (active channel internals, etc.), some should be improved to work correctly (the helium circulatory compressor); certain sub-systems are planned to be integrated to the loop (systems for the determination of moisture and other impurities in helium, etc.). The start of the HTHL operation is expected during 2011 and the integration of the active channel into the LVR-15 core during 2012.

  3. ion with phenolate ions

    Indian Academy of Sciences (India)

    Administrator

    Photoinduced electron transfer (PET) reaction of homoleptic tris-chelated polypyridine ruthenium(II) complexes with phenolate ions is sensitive to the structure of the ligand of the Ru(II) complex as well as of the phenolate ions 1. In recent years 2 the photophysical and photochemical properties of Ru(II) complexes based on ...

  4. How to make Raman-inactive helium visible in Raman spectra of tritium-helium gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Schloesser, M.; Pakari, O.; Rupp, S.; Mirz, S.; Fischer, S. [Institute of Technical Physics, Tritium Laboratory Karlsruhe - TLK, Karlsruhe Institute of Technology - KIT, Karlsruhe (Germany)

    2015-03-15

    Raman spectroscopy, a powerful method for the quantitative compositional analysis of molecular gases, e.g. mixtures of hydrogen isotopologues, is not able to detect monoatomic species like helium. This deficit can be overcome by using radioluminescence emission from helium atoms induced by β-electrons from tritium decay. We present theoretical considerations and combined Raman/radioluminescence spectra. Furthermore, we discuss the linearity of the method together with validation measurements for determining the pressure dependence. Finally, we conclude how this technique can be used for samples of helium with traces of tritium, and vice versa. (authors)

  5. The Liquid Metallic Hydrogen Model of the Sun and the Solar Atmosphere VI. Helium in the Chromosphere

    Directory of Open Access Journals (Sweden)

    Robitaille P.-M.

    2013-07-01

    Full Text Available Molecular hydrogen and hydrides have recently been advanced as vital agents in the generation of emission spectra in the chromosphere. This is a result of the role they play in the formation of condensed hydrogen structures (CHS within the chromosphere (P.M. Robitaille. The Liquid Metallic Hydrogen Model of the Sun and the Solar Atmosphere IV. On the Nature of the Chromosphere. Progr. Phys., 2013, v. 3, 15–21. Next to hydrogen, helium is perhaps the most intriguing component in this region of the Sun. Much like other elements, which combine with hydrogen to produce hydrides, helium can form the well-known helium hydride molecular ion, HeH+, and the excited neutral helium hydride molecule, HeH∗. While HeH+ is hypothesized to be a key cosmologicalmolecule, its possible presence in the Sun, and that of its excited neutral counterpart, has not been considered. Still, these hydrides are likely to play a role in the synthesis of CHS, as the He I and He II emission lines strongly suggest. In this regard, the study of helium emission spectra can provide insight into the condensed nature of the Sun, especially when considering the 10830 Å line associated with the 23P→2 3S triplet state transition. This line is strong in solar prominences and can be seen clearly on the disk. The excessive population of helium triplet states cannot be adequately explained using the gaseous models, since these states should be depopulated by collisional processes. Conversely, when He-based molecules are used to build CHS in a liquid metallic hydrogen model, an ever increasing population of the 23S and 23P states might be expected. The overpopulation of these triplet states leads to the conclusion that these emission lines are unlikely to be produced through random collisional or photon excitation, as required by the gaseous models. This provides a significant hurdle for these models. Thus, the strong 23P→2 3S lines and the overpopulation of the helium triplet

  6. Performance of Screw Compressor for Small-Capacity Helium Refrigerators

    Science.gov (United States)

    Urashin, Masayuki; Matsubara, Katsumi; Izunaga, Yasushi

    A helium compressor is one of the important components comprising a cryogenic refrigerator. The purpous of this investigation is to develop a new small-capacity helium screw compressor. The performance of a single-stage compressor at high compression ratio and the cooling performance of the compressor are investigated. A semi-hermetic screw compressor with new profile screw rotors, with which high performance can be obtained, is utilized in this investigation. Lubricating oil is applied to cool the compressor motor and the compressed gas. As a result, an overall isentropic efficiency of 80% is obtained when helium is compressed to a compression ratio of 19.8 with a single-stage screw compressor. At the same time, the temperature of a compressor motor and discharge gas can be maintained at low levels. Therefore, it is found that a single-stage screw compressor can compress helium to high compression ratio.

  7. Gaseous Helium Reclamation at Rocket Test Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — GHe reclamation is critical in reducing operating costs at rocket engine test facilities. Increases in cost and shortages of helium will dramatically impact testing...

  8. One of the Helium Liquifiers in the North Area

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    Several Helium Liquifiers were installed in the North Area to cool superconducting magnets used in the experiments. At center top is M.Dykes, at bottom right J.Dozio. See CERN Annual Report 1979 p.82.

  9. Self-Calibrating Vector Helium Magnetometer (SVHM) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR proposal describes proposed development of a conceptual design for a Self-Calibrating Vector Helium Magnetometer (SVHM) for design and fabrication...

  10. High-Range Scalar Helium Magnetometer (HSHM) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase I proposal describes development of a conceptual design for a High-range Scalar Helium Magnetometer (HSHM) for the field range +/-16 Gauss. The HSHM...

  11. Helium, hydrogen, and fuzz in plasma-facing materials

    Science.gov (United States)

    Hammond, Karl D.

    2017-10-01

    Tungsten, the primary material under consideration as the divertor material in magnetic-confinement nuclear fusion reactors, has been known for the last decade to form ‘fuzz’—a layer of microscopic, high-void-fraction features on the surface—after only a few hours of exposure to helium plasma. Fuzz has also been observed in molybdenum, tantalum, and several other metals. Helium bubbles in tungsten and other metals are also known to change the hardness of the surface, accumulate at grain boundaries and dislocations, and increase hydrogen isotope retention. This article reviews helium- and hydrogen-induced surface evolution, including fuzz formation, in tungsten and other plasma-facing materials, as well as modeling and experimental efforts that have been undertaken to understand the mechanisms of fuzz formation, helium and hydrogen transport in plasma-facing materials, and relevant atomic-scale and electronic effects relevant to plasma-facing materials.

  12. Dark Matter Detection Using Helium Evaporation and Field Ionization

    Science.gov (United States)

    Maris, Humphrey J.; Seidel, George M.; Stein, Derek

    2017-11-01

    We describe a method for dark matter detection based on the evaporation of helium atoms from a cold surface and their subsequent detection using field ionization. When a dark matter particle scatters off a nucleus of the target material, elementary excitations (phonons or rotons) are produced. Excitations which have an energy greater than the binding energy of helium to the surface can result in the evaporation of helium atoms. We propose to detect these atoms by ionizing them in a strong electric field. Because the binding energy of helium to surfaces can be below 1 meV, this detection scheme opens up new possibilities for the detection of dark matter particles in a mass range down to 1 MeV /c2 .

  13. Advances in molecular mechanism of cardioprotection induced by helium

    Science.gov (United States)

    Ding, Yi-ping; Zhang, Ju-yi; Feng, Dong-xia; Kong, Yan; Xu, Zhuan; Chen, Gang

    2017-01-01

    Helium has been classified as a kind of inert gas that is not effortless to spark chemical reactions with other substances in the past decades. Nevertheless, the cognition of scientists has gradually changed accompanied with a variety of studies revealing the potential molecular mechanism underlying organ-protection induced by helium. Especially, as a non-anesthetic gas which is deficient of relevant cardiopulmonary side effects, helium conditioning is recognized as an emerging and promising approach to exert favorable effects by mimicking the cardioprotection of anesthetic gases or xenon. In this review we will summarize advances in the underlying biological mechanisms and clinical applicability with regards to the cardioprotective effects of helium. PMID:28744366

  14. Gaseous Helium Reclamation at Rocket Test Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The ability to restore large amounts of vented gaseous helium (GHe) at rocket test sites preserves the GHe and reduces operating cost. The used GHe is vented into...

  15. Self-Calibrating Vector Helium Magnetometer (SVHM) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase 2 SBIR proposal describes the design, fabrication and calibration of a brass-board Self-Calibrating Vector Helium Magnetometer (SVHM). The SVHM instrument...

  16. Dark Matter Detection Using Helium Evaporation and Field Ionization.

    Science.gov (United States)

    Maris, Humphrey J; Seidel, George M; Stein, Derek

    2017-11-03

    We describe a method for dark matter detection based on the evaporation of helium atoms from a cold surface and their subsequent detection using field ionization. When a dark matter particle scatters off a nucleus of the target material, elementary excitations (phonons or rotons) are produced. Excitations which have an energy greater than the binding energy of helium to the surface can result in the evaporation of helium atoms. We propose to detect these atoms by ionizing them in a strong electric field. Because the binding energy of helium to surfaces can be below 1 meV, this detection scheme opens up new possibilities for the detection of dark matter particles in a mass range down to 1  MeV/c^{2}.

  17. Future Energy Source. [Mining Helium-3 on the Moon

    Science.gov (United States)

    1990-01-01

    This video describes the efforts of the Center for the Commercial Development of Space in Wisconsin to develop a strategy for mining Helium-3, an efficient, environmentally safe alternative to fossil fuels that exists on the moon. Animated sequences depict the equipment that could mine the lunar surface, boil away Helium-3 to be transported back to earth, and return the soil to the moon without destroying the lunar surface.

  18. Using Electrons on Liquid Helium for Quantum Computing

    OpenAIRE

    Dahm, A. J.; Goodkind, J. M.; Karakurt, I.; Pilla, S.

    2001-01-01

    We describe a quantum computer based on electrons supported by a helium film and localized laterally by small electrodes just under the helium surface. Each qubit is made of combinations of the ground and first excited state of an electron trapped in the image potential well at the surface. Mechanisms for preparing the initial state of the qubit, operations with the qubits, and a proposed readout are described. This system is, in principle, capable of 100,000 operations in a decoherence time.

  19. Robust Ferromagnetism of Chromium Nanoparticles Formed in Superfluid Helium.

    Science.gov (United States)

    Yang, Shengfu; Feng, Cheng; Spence, Daniel; Al Hindawi, Aula M A A; Latimer, Elspeth; Ellis, Andrew M; Binns, Chris; Peddis, Davide; Dhesi, Sarnjeet S; Zhang, Liying; Zhang, Yafei; Trohidou, Kalliopi N; Vasilakaki, Marianna; Ntallis, Nikolaos; MacLaren, Ian; de Groot, Frank M F

    2017-01-01

    Chromium nanoparticles are formed using superfluid helium droplets as the nanoreactors, which are strongly ferromagnetic. The transition from antiferromagentism to ferromagnetism is attributed to atomic-scale disorder in chromium nanoparticles, leading to abundant unbalanced surface spins. Theoretical modeling confirms a frustrated aggregation process in superfluid helium due to the antiferromagnetic nature of chromium. © 2016 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Measurement of the electron and ion temperatures by the x-ray imaging crystal spectrometer on joint Texas experimental tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Yan, W.; Chen, Z. Y., E-mail: zychen@hust.edu.cn; Huang, D. W.; Tong, R. H.; Wang, S. Y.; Wei, Y. N.; Ma, T. K.; Zhuang, G. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan (China); Jin, W. [Center of Interface Dynamics for Sustainability, China Academy of Engineering Physics, Chengdu, Sichuan 610200 (China); Lee, S. G. [National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Shi, Y. J. [Department of Nuclear Engineering, Seoul National University, Seoul 08826 (Korea, Republic of)

    2016-11-15

    An x-ray imaging crystal spectrometer has been developed on joint Texas experimental tokamak for the measurement of electron and ion temperatures from the K{sub α} spectra of helium-like argon and its satellite lines. A two-dimensional multi-wire proportional counter has been applied to detect the spectra. The electron and ion temperatures have been obtained from the Voigt fitting with the spectra of helium-like argon ions. The profiles of electron and ion temperatures show the dependence on electron density in ohmic plasmas.

  1. Helium penetrates into silica glass and reduces its compressibility.

    Science.gov (United States)

    Sato, Tomoko; Funamori, Nobumasa; Yagi, Takehiko

    2011-06-14

    SiO(2) glass has a network structure with a significant amount of interstitial voids. Gas solubilities in silicates are expected to become small under high pressure due to compaction of voids. Here we show anomalous behaviour of SiO(2) glass in helium. Volume measurements clarify that SiO(2) glass is much less compressible than normal when compressed in helium, and the volume in helium at 10 GPa is close to the normal volume at 2 GPa. X-ray diffraction and Raman scattering measurements suggest that voids are prevented from contracting when compressed in helium because helium penetrates into them. The estimated helium solubility is very high and is between 1.0 and 2.3 mol per mole of SiO(2) glass at 10 GPa, which shows marked contrast with previous models. These results may have implications for discussions of the Earth's evolution as well as interpretations of various high-pressure experiments, and also lead to the creation of new materials.

  2. Atomistic simulation of helium bubble nucleation in palladium

    Energy Technology Data Exchange (ETDEWEB)

    Wang Liang [Department of Applied Physics, Hunan University, Changsha 410082 (China); Hu, Wangyu [Department of Applied Physics, Hunan University, Changsha 410082 (China)], E-mail: wangyuhu2001cn@yahoo.com.cn; Xiao Shifang [Department of Applied Physics, Hunan University, Changsha 410082 (China)], E-mail: sfxiao@yahoo.com.cn; Yang Jianyu [Department of Maths and Physics, Hunan Institute of Engineering, Xiangtan 411104 (China); Deng Huiqiu [Department of Applied Physics, Hunan University, Changsha 410082 (China)

    2009-09-15

    A palladium crystal has been constructed with 11808 atoms. 55 helium atoms occupied the octahedral position of palladium crystal are introduced and retained in a spherical region. Molecular dynamic simulations are performed in a constant temperature and constant volume ensemble (NVT) with temperature controlled by Nose-Hoover thermostat. The interactions between palladium atoms are described with modified analytic embedded atom method (MAEAM), the interactions between palladium atom and helium atom are in the form of Morse potential, and the interactions between helium atoms are in the form of L-J potential function. With the analysis of the radial distribution function (RDF) and microstructure, it reveals that some of helium atoms form a series of clusters with different size, and the nucleation core is random at low temperature, and which is the embryo of helium bubble. Increasing temperature can accelerate the process of bubble nucleation, and the clusters will aggregate and coalesce into a bigger one in which there are no palladium atoms, and it is considered as a helium bubble.

  3. Iterative application of two simulation tools to enable the determination of the required airing to preclude mould growth in corners; Iterative Anwendung zweier Rechenmodelle zur Beurteilung der Lueftungserfordernisse fuer eine Vermeidung von Schimmelpilzwachstum

    Energy Technology Data Exchange (ETDEWEB)

    Krus, Martin; Holm, Andreas; Sedlbauer, Klaus [Fraunhofer-Institut fuer Bauphysik (IBP), Fraunhoferstrasse, Valley (Germany)

    2007-04-15

    A newly developed whole building model is able to determine the effect of different ventilation schemes on indoor climate. Feeding the resulting surface temperatures and humidities to a biohygrothermal model allows to assess the risk of mould growth. For given ambient conditions it is thus possible to determine the necessary minimum ventilation rate by iteratively applying the two models. As an example, different building constructions are investigated, showing the effect of different natural ventilation schemes (continuous ventilation versus pulse ventilation by opening the window) on the minimum mean air change rate required for preventing mould growth. (Abstract Copyright [2007], Wiley Periodicals, Inc.) [German] Mit Hilfe eines neu entwickelten Raumklimamodells kann der Einfluss unterschiedlicher Lueftungsvarianten auf das Raumklima berechnet werden. Die Anwendung eines biohygrothermischen Modells gestattet unter Verwendung der berechneten Oberflaechentemperaturen und -feuchten das Schimmelpilzrisiko abzuschaetzen. Fuer gegebene Randbedingungen ist es somit moeglich, die notwendige Lueftung durch eine iterative Anwendung beider Verfahren zu ermitteln. Als Beispiele dienen unterschiedliche Baukonstruktionen, an denen der Einfluss unterschiedlicher Lueftungsstrategien (Dauerlueftung oder Stosslueftung) auf den zur Schimmelpilzvermeidung erforderlichen mittleren Luftwechsel demonstriert wird. (Abstract Copyright [2007], Wiley Periodicals, Inc.)

  4. Formation of Pyrylium from Aromatic Systems with a Helium:Oxygen Flowing Atmospheric Pressure Afterglow (FAPA) Plasma Source

    Science.gov (United States)

    Badal, Sunil P.; Ratcliff, Tyree D.; You, Yi; Breneman, Curt M.; Shelley, Jacob T.

    2017-06-01

    The effects of oxygen addition on a helium-based flowing atmospheric pressure afterglow (FAPA) ionization source are explored. Small amounts of oxygen doped into the helium discharge gas resulted in an increase in abundance of protonated water clusters by at least three times. A corresponding increase in protonated analyte signal was also observed for small polar analytes, such as methanol and acetone. Meanwhile, most other reagent ions (e.g., O2 +·, NO+, etc.) significantly decrease in abundance with even 0.1% v/v oxygen in the discharge gas. Interestingly, when analytes that contained aromatic constituents were subjected to a He:O2-FAPA, a unique (M + 3)+ ion resulted, while molecular or protonated molecular ions were rarely detected. Exact-mass measurements revealed that these (M + 3)+ ions correspond to (M - CH + O)+, with the most likely structure being pyrylium. Presence of pyrylium-based ions was further confirmed by tandem mass spectrometry of the (M + 3)+ ion compared with that of a commercially available salt. Lastly, rapid and efficient production of pyrylium in the gas phase was used to convert benzene into pyridine. Though this pyrylium-formation reaction has not been shown before, the reaction is rapid and efficient. Potential reactant species, which could lead to pyrylium formation, were determined from reagent-ion mass spectra. Thermodynamic evaluation of reaction pathways was aided by calculation of the formation enthalpy for pyrylium, which was found to be 689.8 kJ/mol. Based on these results, we propose that this reaction is initiated by ionized ozone (O3 +·), proceeds similarly to ozonolysis, and results in the neutral loss of the stable CHO2 · radical. [Figure not available: see fulltext.

  5. Formation of Pyrylium from Aromatic Systems with a Helium:Oxygen Flowing Atmospheric Pressure Afterglow (FAPA) Plasma Source.

    Science.gov (United States)

    Badal, Sunil P; Ratcliff, Tyree D; You, Yi; Breneman, Curt M; Shelley, Jacob T

    2017-06-01

    The effects of oxygen addition on a helium-based flowing atmospheric pressure afterglow (FAPA) ionization source are explored. Small amounts of oxygen doped into the helium discharge gas resulted in an increase in abundance of protonated water clusters by at least three times. A corresponding increase in protonated analyte signal was also observed for small polar analytes, such as methanol and acetone. Meanwhile, most other reagent ions (e.g., O 2 +· , NO + , etc.) significantly decrease in abundance with even 0.1% v/v oxygen in the discharge gas. Interestingly, when analytes that contained aromatic constituents were subjected to a He:O 2 -FAPA, a unique (M + 3) + ion resulted, while molecular or protonated molecular ions were rarely detected. Exact-mass measurements revealed that these (M + 3) + ions correspond to (M - CH + O) + , with the most likely structure being pyrylium. Presence of pyrylium-based ions was further confirmed by tandem mass spectrometry of the (M + 3) + ion compared with that of a commercially available salt. Lastly, rapid and efficient production of pyrylium in the gas phase was used to convert benzene into pyridine. Though this pyrylium-formation reaction has not been shown before, the reaction is rapid and efficient. Potential reactant species, which could lead to pyrylium formation, were determined from reagent-ion mass spectra. Thermodynamic evaluation of reaction pathways was aided by calculation of the formation enthalpy for pyrylium, which was found to be 689.8 kJ/mol. Based on these results, we propose that this reaction is initiated by ionized ozone (O 3 +· ), proceeds similarly to ozonolysis, and results in the neutral loss of the stable CHO 2 · radical. Graphical Abstract ᅟ.

  6. First observation and mobility measurements of negative ions in superfluid He-4

    NARCIS (Netherlands)

    Kasimova, A; Zuhlke, C; Jungmann, K; Putlitz, GZ

    We present the results of the first mobility measurements in superfluid helium for negative ions of different elements. Various negative ions like Cl-, F- and I- were produced by laser ablation from targets consisting of NaCl, NaF, NaI, LiF and KCl immersed in a He-4 bath. In addition to negative

  7. Measurement of helium production cross sections of iron for d-T neutrons by helium accumulation method

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Yoshiyuki; Kanda, Yukinori; Nagae, Koji; Fujimoto, Toshihiro [Kyushu Univ., Fukuoka (Japan); Ikeda, Yujiro

    1997-03-01

    Helium production cross sections of Iron were measured by helium accumulation method for neutron energies from 13.5 to 14.9 MeV. Iron samples were irradiated with FNS, an intense d-T neutron source of JAERI. As the neutron energy varies according to the emission angle at the neutron source, the samples were set around the neutron source and were irradiated by neutrons of different energy depending on each sample position. The amount of helium produced in a sample was measured by Helium Atoms Measurement System at Kyushu University. The results of this work are in good agreement with other experimental data in the literature and also compared with the evaluated values in JENDL-3. (author)

  8. A LASER ION-SOURCE FOR ONLINE MASS SEPARATION

    NARCIS (Netherlands)

    VANDUPPEN, P; DENDOOVEN, P; HUYSE, M; VERMEEREN, L; QAMHIEH, ZN; SILVERANS, RE; VANDEWEERT, E

    1992-01-01

    A laser ion source based on resonance photo ionization in a gas cell is proposed. The gas cell, filled with helium, consists of a target chamber in which the recoil products are stopped and neutralized, and an ionization chamber where the atoms of interest are selectively ionized by the laser light.

  9. Cavity optomechanics in a levitated helium drop

    Science.gov (United States)

    Childress, L.; Schmidt, M. P.; Kashkanova, A. D.; Brown, C. D.; Harris, G. I.; Aiello, A.; Marquardt, F.; Harris, J. G. E.

    2017-12-01

    We describe a proposal for a type of optomechanical system based on a drop of liquid helium that is magnetically levitated in vacuum. In the proposed device, the drop would serve three roles: its optical whispering-gallery modes would provide the optical cavity, its surface vibrations would constitute the mechanical element, and evaporation of He atoms from its surface would provide continuous refrigeration. We analyze the feasibility of such a system in light of previous experimental demonstrations of its essential components: magnetic levitation of mm-scale and cm-scale drops of liquid He , evaporative cooling of He droplets in vacuum, and coupling to high-quality optical whispering-gallery modes in a wide range of liquids. We find that the combination of these features could result in a device that approaches the single-photon strong-coupling regime, due to the high optical quality factors attainable at low temperatures. Moreover, the system offers a unique opportunity to use optical techniques to study the motion of a superfluid that is freely levitating in vacuum (in the case of 4He). Alternatively, for a normal fluid drop of 3He, we propose to exploit the coupling between the drop's rotations and vibrations to perform quantum nondemolition measurements of angular momentum.

  10. Helium-Shell Nucleosynthesis and Extinct Radioactivities

    Science.gov (United States)

    Meyer, B. S.; The, L.-S.; Clayton, D. D.; ElEid, M. F.

    2004-01-01

    Although the exact site for the origin of the r-process isotopes remains mysterious, most thinking has centered on matter ejected from the cores of massive stars in core-collapse supernovae [13]. In the 1970's and 1980's, however, difficulties in understanding the yields from such models led workers to consider the possibility of r-process nucleosynthesis farther out in the exploding star, in particular, in the helium burning shell [4,5]. The essential idea was that shock passage through this shell would heat and compress this material to the point that the reactions 13C(alpha; n)16O and, especially, 22Ne(alpha; n)25Mg would generate enough neutrons to capture on preexisting seed nuclei and drive an "n process" [6], which could reproduce the r-process abundances. Subsequent work showed that the required 13C and 22Ne abundances were too large compared to the amounts available in realistic models [7] and recent thinking has returned to supernova core material or matter ejected from neutron star-neutron star collisions as the more likely r-process sites.

  11. Thermal desorption of deuterium from Be, and Be with helium bubbles

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, A.V.; Van Veen, A.; Busker, G.J. [Delft Univ. of Technology (Netherlands). Interfaculty Reactor Inst.

    1998-01-01

    Deuterium desorption measurements carried out on a single-crystalline beryllium sample are presented. Deuterium ions were implanted at room temperature at the energy of 0.7 and 1.2 keV up to doses ranging from 10{sup 19} to 3.6 x 10{sup 21} m{sup -2}. In order to eliminate the influence of the beryllium-oxide surface layer, before the implantation the surface of the sample was cleaned by argon sputtering. After the implantation the sample was annealed up to 1200 K at a constant rate of 10 K/s. Deuterium released from the sample was monitored by a calibrated quadrupole mass-spectrometer. The desorption spectra revealed two different contributions. One is a well defined and very narrow peak centered around 450 K. This peak is observed only at high implantation doses > 7.8 x 10{sup 20} m{sup -2}, which is close to the deuterium saturation limit of 0.3 D/Be and is related to deuterium release from blisters or interconnected bubbles. The activation energy of 1.1 eV and the threshold implantation dose are consistent with the values reported in literature. The second contribution in the release spectra is found in the temperature range from 600 to 900 K and is present throughout the whole range of the implantation doses. The activation energies corresponding to this release lie in the range between 1.8 and 2.5 eV and are ascribed to the release from deuterium-vacancy type of defects. In a number of experiments the deuterium implantation was preceded by helium implantation followed by partial annealing to create helium bubbles. The resulting deuterium desorption spectra indicate that deuterium detrapping from helium bubbles is characterized by an activation energy of 2.7 eV. (author)

  12. On the Stark broadening in the Au I and Au II spectra from a helium plasma

    Science.gov (United States)

    Djeniže, S.

    2009-03-01

    The Stark FWHM (Full-Width at Half of the Maximal line intensity, W) of 5 neutral and 26 singly ionized gold (Au I and Au II, respectively) spectral lines have been measured in laboratory helium plasma at approximately 16,600 K electron temperature and 7.4 × 10 22 m - 3 electron density. Five Au I and ten Au II W values are reported for the first time. The Au II W values are compared with recent theoretical data, calculated based on a modified semi-empirical approach, and also with existing experimental W values. Our normalized Stark widths are six times higher than those measured in a laser-produced plasma. Possible explanation of this is recommended here. An agreement (within the accuracy of the experiment and uncertainties of the theoretical approach used) with the recently calculated W data was found in the 6p-7s Au II transition. The calculated hyperfine splitting for the five Au II lines in the 6s-6p transition is also presented. At the stated helium plasma conditions, Stark broadening has been found to be the dominant mechanism in the Au I and Au II line shape formation. A modified version of the linear low-pressure pulsed arc was used as a plasma source operated in helium, with gold atoms as impurities evaporated from the thin gold cylindrical plates located in the homogeneous part of the discharge, providing conditions free of self-absorption. This plasma source ensures good conditions for generation of excited gold ions due to Penning and charge exchange effects.

  13. Carbon, Helium, and Proton Kinetic Temperatures in a Cygnus Loop Shock Wave

    Science.gov (United States)

    Raymond, John C.; Edgar, Richard J.; Ghavamian, Parviz; Blair, William P.

    2015-06-01

    Observations of SN 1006 have shown that ions and electrons in the plasma behind fast supernova remnant shock waves are far from equilibrium, with the electron temperature much lower than the proton temperature and ion temperatures approximately proportional to ion mass. In the ˜360 km s-1shock waves of the Cygnus Loop, on the other hand, electron and ion temperatures are roughly equal, and there is evidence that the oxygen kinetic temperature is not far from the proton temperature. In this paper, we report observations of the He ii λ1640 line and the C iv λ1550 doublet in a 360 km s-1shock in the Cygnus Loop. While the best-fit kinetic temperatures are somewhat higher than the proton temperature, the temperatures of He and C are consistent with the proton temperature and the upper limits are 0.5 and 0.3 times the mass-proportional temperatures, implying efficient thermal equilibration in this collisionless shock. The equilibration of helium and hydrogen affects the conversion between proton temperatures determined from Hα line profiles and shock speeds, and the efficient equilibration found here reduces the shock speed estimates and the distance estimate to the Cygnus Loop of Medina et al. to about 800 pc.

  14. Ionization efficiency studies for xenon ions with thesuperconducting ECR ion source VENUS

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, Daniela; Lyneis, Claude M.; Todd, DamonS.; Tarvainen,Olli

    2007-06-05

    Ionization efficiency studies for high charge state xenon ions using a calibrated gas leak are presented. A 75% enriched {sup 129}Xe gas leak with a gas flow equivalent to 5.11p{mu}A was used in all the measurements. The experiments were performed at the VENUS (Versatile ECR ion source for Nuclear Science) ion source for 18 GHz, 28 GHz and double frequency operation. Overall, total ionization efficiencies close to 100% and ionization efficiencies into a single charge state up to 22% were measured. The influence of the biased disk on the ionization efficiency was studied and the results were somewhat surprising. When the biased disk was removed from the plasma chamber, the ionization efficiency was dramatically reduced for single frequency operation. However, using double frequency heating the ionization efficiencies achieved without the biased disk almost matched the ionization efficiencies achieved with the biased probe. In addition, we have studied the influence of the support gas on the charge state distribution of the xenon ions. Either pure oxygen or a mixture of oxygen and helium were used as support gases. The addition of a small amount of helium can increase the ionization efficiency into a single charge state by narrowing the charge state distribution. Furthermore by varying the helium flow the most efficient charge state can be shifted over a wide range without compromising the ionization efficiency. This is not possible using only oxygen as support gas. Results from these studies are presented and discussed.

  15. Ion spectroscopy for improvement of the physical beam model for therapy planning in ion beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Arico, Giulia

    2016-11-23

    Helium and carbon ions enable a more conformal dose distribution, narrower penumbra and higher relative biological effectiveness than photon and proton radiotherapy. However, they may undergo nuclear fragmentation in the patient tissues and the arising secondary fragments affect the delivered biological dose distributions. Currently there is a lack of data regarding ion nuclear fragmentation. One reason is the large size (up to some meters) of the experimental setups required for the investigations. In this thesis a new method is presented, which makes use of versatile pixelated semiconductor detectors (Timepix). This method is based on tracking of single particles and pattern recognition of their signals in the detectors. Measurements were performed at the HIT facility. The mixed radiation field arising from 430 MeV/u carbon ion beams and 221 MeV/u helium ion beams in water and in PMMA targets was investigated. The amounts of primary (carbon or helium) ions detected behind targets with the same water equivalent thickness (WET) were found to be in agreement within the statistical uncertainties. However, more fragments (differences up to 20% in case of H) and narrower lateral particle distributions were measured behind the PMMA than the water targets. The spectra of ions behind tissue surrogates and corresponding water targets with the same WET were analysed. The results obtained with adipose and inner bone surrogates and with the equivalent water phantoms were found to be consistent within the uncertainties. Significant differences in the results were observed in the case of lung and cortical bone surrogates when compared to the water phantoms. The experimental results were compared to FLUKA Monte Carlo simulations. This comparison could contribute to enhance the ion interaction models currently implemented for {sup 12}C and {sup 4}He ion beams.

  16. Radioactive Ion Beam Development at the Holifield Radioactive Ion Beam Facility

    CERN Document Server

    Stracener, Dan; Beene, James R; Bilheux, Hassina Z; Bilheux, Jean-Christophe; Blackmon, Jeff C; Carter, Ken; Dowling, Darryl; Juras, Raymond; Kawai, Yoko; Kronenberg, Andreas; Liu, Yuan; Meigs, Martha; Müller, Paul; Spejewski, Eugene H; Tatum, A

    2005-01-01

    Radioactive beams are produced at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory using the Isotope Separator On-Line (ISOL) technique. Radioactive nuclei are produced in a thick target via irradiation with energetic light ions (protons, deuterons, helium isotopes) and then post-accelerated to a few MeV/nucleon for use in nuclear physics experiments. An overview of radioactive beam development at the HRIBF will be presented, including ion source development, improvements in the ISOL production targets, and a description of techniques to improve the quality (intensity and purity) of the beams. Facilities for radioactive ion beam development include two ion source test facilities, a target/ion source preparation and quality assurance facility, and an in-beam test facility where low intensity production beams are used. A new test facility, the High Power Target Laboratory, will be available later this year. At this facility, high intensity production beams will be available t...

  17. Thermal vacancies and phase separation in bcc mixtures of helium-3 and helium-4

    Energy Technology Data Exchange (ETDEWEB)

    Fraass, Benedick Andrew [Univ. of Illinois, Urbana-Champaign, IL (United States). Dept. of Physics

    1980-01-01

    Thermal vacancy concentrations in crystals of 3He-4He mixtures have been determined. A new x-ray diffractometer-position sensitive detector system is used to make measurements of the absolute lattice parameter of the helium crystals with an accuracy of 300 ppM, and measurements of changes in lattice parameters to better than 60 ppM. The phase separation of the concentrated3He-4He mixtures has been studied in detail with the x-ray measurements. Vacancy concentrations in crystals with 99%, 51%, 28%, 12%, and 0% 3He have been determined. Phase separation has been studied in mixed crystals with concentrations of 51%, 28%, and 12% 3He and melting pressures between 3.0 and 6.1 MPa. The phase separation temperatures determined in this work are in general agreement with previous work. The pressure dependence of Tc, the phase separation temperature for a 50% mixture, is found to be linear: dTc/dP = -34 mdeg/MPa. The x-ray measurements are used to make several comments on the low temperature phase diagram of the helium mixtures.

  18. An advanced time-dependent collisional-radiative model of helium plasma discharges

    Science.gov (United States)

    Claustre, J.; Boukandou-Mombo, C.; Margot, J.; Matte, J.-P.; Vidal, F.

    2017-10-01

    A new spatially averaged time-dependent collisional-radiative model for helium plasmas, coupled to the electron Boltzmann equation (EBE), has been developed. Its main novelties are: (1) full time dependence for both the multi-species kinetics and the EBE. It is shown that this is necessary to correctly simulate discharges where the parameters vary on nanoseconds-microsecond timescales. (2) All electron processes are accounted for accurately. In particular, for the various ionization and recombination processes, free electrons are added or removed at the appropriate energy, with the appropriate interpolation on the energy grid. (3) The energy dependence of the electron loss by ambipolar diffusion is taken into account approximately. (4) All of the processes which are known to be important in helium discharges for pressure P≤slant 760 Torr are included, and 42 energy levels up to n = 6, where n is the main quantum number, are taken into account. Atomic and molecular ions, as well as excimers, are also included. (5) The gas temperature is calculated self-consistently. The model is validated through comparisons with known numerical steady-state results of Santos et al (2014 J. Phys. D. 47 265201) which they compared to their experimental results, and good agreement is obtained for their measured quantities. It is then applied to post-discharge decay cases with very short power decay times. The time evolution of the population densities and reaction rates are analyzed in detail with emphasis on the observed large increase of the metastable density.

  19. Cross section database for collision processes of helium atom with charged particles. 1. Electron impact processes

    Energy Technology Data Exchange (ETDEWEB)

    Ralchenko, Yu.V.; Janev, R.K.; Kato, T. [National Inst. for Fusion Science, Toki, Gifu (Japan); Fursa, D.V.; Bray, I. [Flinder Univ., Adelaide (Australia); Heer, F.J. de [FOM Institute for Atomic and Molecular Physics, Amsterdam (Netherlands)

    2000-10-01

    A comprehensive and critically assessed cross section database for the inelastic collision processes of ground state and excited helium atoms colliding with electrons, protons and multiply-charged ions has been prepared at the Data and Planning Center at NIFS. The present report describes the first part of the database containing the recommended data for electron impact excitation and ionization of neutral helium. An states (atomic terms) with n {<=} 4 are treated individually while the states with n > 4 are considered degenerate. For the processes involving transitions to and from n > 4 levels, suitable cross section scaling relations are presented. For a large number of electron impact transitions, both from the ground and excited states, new convergent close coupling (CCC) calculations were performed to achieve a high accuracy of the data. The evaluated/recommended cross section data are presented by analytic fit functions which preserve the correct asymptotic behavior of the cross sections. The cross sections are also displayed in a graphical form. (author)

  20. Ultra-High Sensitivity Techniques for the Determination of 3 He /4 He Abundances in Helium by Accelerator Mass Spectrometry

    Science.gov (United States)

    Mumm, H. P.; Huber, M.; Bauder, W.; Abrams, N.; Deibel, C.; Huffer, C.; Huffman, P.; Schelhammer, K.; Janssens, R.; Jiang, C.; Scott, R.; Pardo, R.; Rehm, K.; Vondrasek, R.; Swank, C.; O'Shaughnessy, C.; Paul, M.; Yang, L.

    2017-01-01

    We report the development of an Accelerator Mass Spectrometry technique to measure the 3He/4He isotopic ratio using a radio frequency (RF) discharge source and the ATLAS facility at Argonne National Laboratory. Control over 3He/4He ratio in helium several orders of magnitude lower than natural abundance is critical for neutron lifetime and source experiments using liquid helium. Due to low ultimate beam currents, the ATLAS accelerator and beam line were tuned using a succession of species of the same M/q. A unique RF source was developed for the experiment due to large natural 3He backgrounds. Analog H_3 + and DH + molecular ions are eliminated by dissociation via a gold stripper foil near the detector. The stripped ions were dispersed in a magnetic spectrograph and 3He2 + ions counted in the focal plane detector. This technique is sensitive to 3 He /4 He ratios in the regime of 10-12 with backgrounds that appear to be below 10-14. The techniques used to reduce the backgrounds and remaining outstanding problems will be presented along with results from measurements on high purity 4He samples.

  1. LRO-LAMP Observations of Lunar Exospheric Helium

    Science.gov (United States)

    Grava, Cesare; Retherford, Kurt D.; Hurley, Dana M.; Feldman, Paul D.; Gladstone, Randy; Greathouse, Thomas K.; Cook, Jason C.; Stern, Alan; Pryor, Wayne R.; Halekas, Jasper S.; Kaufmann, David E.

    2015-11-01

    We present results from Lunar Reconnaissance Orbiter’s (LRO) UV spectrograph LAMP (Lyman-Alpha Mapping Project) campaign to study the lunar atmosphere. Two kinds of off-nadir maneuvers (lateral rolls and pitches towards and opposite the direction of motion of LRO) were performed to search for resonantly scattering species, increasing the illuminated line-of-sight (and hence the signal from atoms resonantly scattering the solar photons) compared to previously reported LAMP “twilight observations” [Cook & Stern, 2014]. Helium was the only element distinguishable on a daily basis, and we present latitudinal profiles of its line-of-sight column density in December 2013. We compared the helium line-of-sight column densities with solar wind alpha particle fluxes measured from the ARTEMIS (Acceleration, Reconnection, Turbulence, & Electrodynamics of Moon’s Interaction with the Sun) twin spacecraft. Our data show a correlation with the solar wind alpha particle flux, confirming that the solar wind is the main source of the lunar helium, but not with a 1:1 relationship. Assuming that the lunar soil is saturated with helium atoms, our results suggest that not all of the incident alpha particles are converted to thermalized helium, allowing for a non-negligible fraction (~50 %) to escape as suprathermal helium or simply backscattered from the lunar surface. We also support the finding by Benna et al. [2015] and Hurley et al. [2015], that a non-zero contribution from endogenic helium, coming from radioactive decay of 232Th and 238U within the mantle, is present, and is estimated to be (4.5±1.2) x 106 He atoms cm-2 s-1. Finally, we compare LAMP-derived helium surface density with the one recorded by the mass spectrometer LACE (Lunar Atmospheric Composition Experiment) deployed on the lunar surface during the Apollo 17 mission, finding good agreement between the two measurements. These LRO off-nadir maneuvers allow LAMP to provide unique coverage of local solar time and

  2. Theoretical model of the helium zone plate microscope

    Science.gov (United States)

    Salvador Palau, Adrià; Bracco, Gianangelo; Holst, Bodil

    2017-01-01

    Neutral helium microscopy is a new technique currently under development. Its advantages are the low energy, charge neutrality, and inertness of the helium atoms, a potential large depth of field, and the fact that at thermal energies the helium atoms do not penetrate into any solid material. This opens the possibility, among others, for the creation of an instrument that can measure surface topology on the nanoscale, even on surfaces with high aspect ratios. One of the most promising designs for helium microscopy is the zone plate microscope. It consists of a supersonic expansion helium beam collimated by an aperture (skimmer) focused by a Fresnel zone plate onto a sample. The resolution is determined by the focal spot size, which depends on the size of the skimmer, the optics of the system, and the velocity spread of the beam through the chromatic aberrations of the zone plate. An important factor for the optics of the zone plate is the width of the outermost zone, corresponding to the smallest opening in the zone plate. The width of the outermost zone is fabrication limited to around 10 nm with present-day state-of-the-art technology. Due to the high ionization potential of neutral helium atoms, it is difficult to build efficient helium detectors. Therefore, it is crucial to optimize the microscope design to maximize the intensity for a given resolution and width of the outermost zone. Here we present an optimization model for the helium zone plate microscope. Assuming constant resolution and width of the outermost zone, we are able to reduce the problem to a two-variable problem (zone plate radius and object distance) and we show that for a given beam temperature and pressure, there is always a single intensity maximum. We compare our model with the highest-resolution zone plate focusing images published and show that the intensity can be increased seven times. Reducing the width of the outermost zone to 10 nm leads to an increase in intensity of more than 8000

  3. Optomechanics in a Levitated Droplet of Superfluid Helium

    Science.gov (United States)

    Brown, Charles; Harris, Glen; Harris, Jack

    2017-04-01

    A critical issue common to all optomechanical systems is dissipative coupling to the environment, which limits the system's quantum coherence. Superfluid helium's extremely low optical and mechanical dissipation, as well as its high thermal conductivity and its ability cool itself via evaporation, makes the mostly uncharted territory of superfluid optomechanics an exciting avenue for exploring quantum effects in macroscopic objects. I will describe ongoing work that aims to exploit the unique properties of superfluid helium by constructing an optomechanical system consisting of a magnetically levitated droplet of superfluid helium., The optical whispering gallery modes (WGMs) of the droplet, as well as the mechanical oscillations of its surface, should offer exceptionally low dissipation, and should couple to each other via the usual optomechanical interactions. I will present recent progress towards this goal, and also discuss the background for this work, which includes prior demonstrations of magnetic levitation of superfluid helium, high finesse WGMs in liquid drops, and the self-cooling of helium drops in vacuum.

  4. Rotovibrational spectroscopy of hydrogen peroxide embedded in superfluid helium nanodroplets.

    Science.gov (United States)

    Raston, Paul L; Knapp, Chrissy J; Jäger, Wolfgang

    2011-11-14

    We report the infrared depletion spectrum of para- and ortho-hydrogen peroxide embedded in superfluid helium nanodroplets in the OH stretching region. Six transitions were observed in the antisymmetric stretching band (v(5)) of H(2)O(2), and three in the weaker symmetric stretching band (v(1)). While rotations about the b- and c-axes are slowed by a factor of ∼0.4 relative to the gas phase, rotations about the a-axis are not significantly affected; this relates to the rotational speed about the a-axis being too fast for helium density to adiabatically follow. The trans tunneling splitting does not appear to be considerably affected by the helium droplet environment, and is reduced by only 6% relative to the gas phase, under the assumption that the vibrational shifts of the v(5) and v(1) torsional subbands are the same. The linewidths increase with increasing rotorsional energies, and are significantly narrower for energies which fall within the "phonon gap" of superfluid helium. These narrower lines are asymmetrically broadened, indicative of a dynamical coupling between the H(2)O(2) rotor and surrounding helium density.

  5. Validation of Helium Inlet Design for ITER Toroidal Field Coil

    CERN Document Server

    Boyer, C; Hamada, K; Foussat, A; Le Rest, M; Mitchell, N; Decool, P; Savary, F; Sgobba, S; Weiss, K-P

    2014-01-01

    The ITER organization has performed design and its validation tests on a helium inlet structure for the ITER Toroidal Field (TF) coil under collaboration with CERN, KIT, and CEA-Cadarache. Detailed structural analysis was performed in order to optimize the weld shape. A fatigue resistant design on the fillet weld between the shell covers and the jacket is an important point on the helium inlet structure. A weld filler material was selected based on tensile test at liquid helium temperature after Nb3Sn reaction heat treatment. To validate the design of the weld joint, fatigue tests at 7 K were performed using heat-treated butt weld samples. A pressure drop measurement of a helium inlet mock-up was performed by using nitrogen gas at room temperature in order to confirm uniform flow distribution and pressure drop characteristic. These tests have validated the helium inlet design. Based on the validation, Japanese and European Union domestic agencies, which have responsibilities of the TF coil procurement, are pr...

  6. Investigation of a planar optical waveguide in 2D PPLN using helium implantation technique.

    Science.gov (United States)

    Ripault, Q; Lee, M W; Mériche, F; Touam, T; Courtois, B; Ntsoenzok, E; Peng, L-H; Fischer, A; Boudrioua, A

    2013-03-25

    In this work, we report the investigation of a planar waveguide in a 2D periodically-poled lithium niobate (PPLN). The waveguide is fabricated by helium (He(+)) implantation at 2 MeV and a fluence of 1.5 x 10(16) ions/cm(2). Second harmonic generation (SHG) at 532 nm using a Q-switched laser and a CW laser diode at 1064 nm, was measured as a function of angular distribution and temperature. The experimental results show higher gain in SHG conversion efficiency in the waveguide than in the bulk 2D PPLN. In particular, SHGs from 2D reciprocal lattice vectors (RLV) are observed and studied.

  7. Development of miniaturized, spectroscopically assisted Penning gauges for fractional helium and hydrogen neutral pressure measurements.

    Science.gov (United States)

    Flesch, K; Kremeyer, T; Schmitz, O; Soukhanovskii, V; Wenzel, U

    2016-11-01

    Direct measurements of the helium (He) fractional neutral pressure in the neutral gas around fusion devices is challenging because of the small mass difference between the abundant D2 molecules and the He ash which will be produced by deuterium-tritium fusion. To study He exhaust, an in situ Penning gauge system is being developed at UW-Madison that is optimized for good pressure and high spectroscopic sensitivity. Three different anode geometries have been studied regarding their vacuum electrostatic fields, light output, and ion current. The light output of the two new anode configurations are at least one order of magnitude above the currently available designs, hence improving the spectroscopic sensitivity at similar total neutral pressure resolution.

  8. Theory for charge states of energetic oxygen ions in the earth's radiation belts

    Science.gov (United States)

    Spjeldvik, W. N.; Fritz, T. A.

    1978-01-01

    Fluxes of geomagnetically trapped energetic oxygen ions have been studied in detail. Ion distributions in radial locations below the geostationary orbit, energy spectra between 1 keV and 100 MeV, and the distribution over charge states have been computed for equatorially mirroring ions. Both ionospheric and solar wind oxygen ion sources have been considered, and it is found that the charge state distributions in the interior of the radiation belts are largely independent of the charge state characteristics of the sources. In the MeV range, oxygen ions prove to be a more sensitive probe for radiation belt dynamics than helium ions and protons.

  9. Dense Plasma Focus With High Energy Helium Beams for Radiological Source Replacement

    Science.gov (United States)

    Schmidt, Andrea; Ellsworth, Jennifer; Falabella, Steve; Link, Anthony; Rusnak, Brian; Sears, Jason; Tang, Vincent

    2014-10-01

    A dense plasma focus (DPF) is a compact accelerator that can produce intense high energy ion beams (multiple MeV). It could be used in place of americium-beryllium (AmBe) neutron sources in applications such as oil well logging if optimized to produce high energy helium beams. AmBe sources produce neutrons when 5.5 MeV alphas emitted from the Am interact with the Be. However, due to the very small alpha-Be cross section for alphas AmBe source replacement would have to accelerate ~0.15 μC of He to 2 + MeV in order to produce 107 neutrons per pulse. We are using our particle in cell (PIC) model in LSP of a 4 kJ dense plasma focus discharge to guide the optimization of a compact DPF for the production of high-energy helium beam. This model is fluid for the run-down phase, and then transitions to fully kinetic prior to the pinch in order to include kinetic effects such as ion beam formation and anomalous resistivity. An external pulsed-power driver circuit is used at the anode-cathode boundary. Simulations will be benchmarked to He beam measurements using filtered and time-of-flight Faraday cup diagnostics. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. This work supported by US DOE/NA-22 Office of Non-proliferation Research and Development. Computing support for this work came from the LLNL Institutional Computing Grand Challenge program.

  10. Dopant-induced ignition of helium nanoplasmas—a mechanistic study

    Science.gov (United States)

    Heidenreich, Andreas; Schomas, Dominik; Mudrich, Marcel

    2017-12-01

    Helium (He) nanodroplets irradiated by intense near-infrared laser pulses form a nanoplasma by avalanche-like electron impact ionizations (EIIs) even at lower laser intensities where He is not directly field ionized, provided that the droplets contain a few dopant atoms which provide seed electrons for the EII avalanche. In this theoretical paper on calcium and xenon doped He droplets we elucidate the mechanism which induces ionization avalanches, termed ignition. We find that the partial loss of seed electrons from the activated droplets starkly assists ignition, as the Coulomb barrier for ionization of helium is lowered by the electric field of the dopant cations, and this deshielding of the cation charges enhances their electric field. In addition, the dopant ions assist the acceleration of the seed electrons (slingshot effect) by the laser field, supporting EIIs of He and also causing electron loss by catapulting electrons away. The dopants’ ability to lower the Coulomb barriers at He as well as the slingshot effect decrease with the spatial expansion of the dopant, causing a dependence of the dopants’ ignition capability on the dopant mass. Here, we develop criteria (impact count functions) to assess the ignition capability of dopants, based on (i) the spatial overlap of the seed electron cloud with the He atoms and (ii) the overlap of their kinetic energy distribution with the distribution of Coulomb barrier heights at He. The relatively long time delays between the instants of dopant ionization and ignition (incubation times) for calcium doped droplets are determined to a large extent by the time it takes to deshield the dopant ions.

  11. Breakdown in helium in high-voltage open discharge with subnanosecond current front rise

    Energy Technology Data Exchange (ETDEWEB)

    Schweigert, I. V., E-mail: ischweig@itam.nsc.ru; Alexandrov, A. L. [Russian Academy of Sciences, Khristianovich Institute of Theoretical and Applied Mechanics, Siberian Branch (Russian Federation); Bokhan, P. A.; Zakrevskiy, Dm. E. [Russian Academy of Sciences, Rzhanov Institute of Semiconductors Physics, Siberian Branch (Russian Federation)

    2016-07-15

    Investigations of high-voltage open discharge in helium have shown a possibility of generation of current pulses with subnanosecond front rise, due to ultra-fast breakdown development. The open discharge is ignited between two planar cathodes with mesh anode in the middle between them. For gas pressure 6 Torr and 20 kV applied voltage, the rate of current rise reaches 500 A/(cm{sup 2} ns) for current density 200 A/cm{sup 2} and more. The time of breakdown development was measured for different helium pressures and a kinetic model of breakdown in open discharge is presented, based on elementary reactions for electrons, ions and fast atoms. The model also includes various cathode emission processes due to cathode bombardment by ions, fast atoms, electrons and photons of resonant radiation with Doppler shift of frequency. It is shown, that the dominating emission processes depend on the evolution of the discharge voltage during the breakdown. In the simulations, two cases of voltage behavior were considered: (i) the voltage is kept constant during the breakdown; (ii) the voltage is reduced with the growth of current. For the first case, the exponentially growing current is maintained due to photoemission by the resonant photons with Doppler-shifted frequency. For the second case, the dominating factor of current growth is the secondary electron emission. In both cases, the subnanosecond rise of discharge current was obtained. Also the effect of gas pressure on breakdown development was considered. It was found that for 20 Torr gas pressure the time of current rise decreases to 0.1 ns, which is in agreement with experimental data.

  12. Influence of structural-phase state of ferritic-martensitic steels on the helium porosity development

    Science.gov (United States)

    Chernov, I. I.; Staltsov, M. S.; Kalin, B. A.; Bogachev, I. A.; Guseva, L. Yu; Dzhumaev, P. S.; Emelyanova, O. V.; Drozhzhina, M. V.; Manukovsky, K. V.; Nikolaeva, I. D.

    2016-04-01

    Transmission electron microscopy (TEM) has been used to study the effect of the initial structural-phase state (SPhS) of ferritic-martensitic steels EK-181, EP-450 and EP-450- ODS (with 0.5 wt.% nanoparticles of Y2O3) on the of helium porosity formation and gas swelling. Different SPhS of steel EK-181 was produced by water quenching, annealing, normalizing plus tempered, intensive plastic deformation by torsion (HPDT). Irradiation was carried out by He+-40 keV ions at 923 K up to fluence of 5-1020 He+/m2. It is shown that the water quenching causes the formation of uniformly distributed small bubbles (d¯ ∼ 2 nm) of the highest density (ρ∼ 1025 m-3). After normalization followed by tempering as well as after annealing bubbles distribution is highly non-uniform both by volume and in size. Very large faceted bubbles (pre-equilibrium gas-filled voids) are formed in ferrite grains resulting in high level of gas swelling of the irradiated layer with S = 4,9 ± 1,2 and 3.8 ± 0.9% respectively. Nano- and microcrystalline structure created by HPDT completely degenerate at irradiation temperature and ion irradiation formed bubbles of the same parameters as in the annealed steel. Bubbles formed in EP-450-ODS steel are smaller in size and density, which led to a decrease of helium swelling by 4 times (S = 0.8 ± 0.2%) as compared to the swelling of the matrix steel EP-450 (S = 3.1 ± 0.7%).

  13. Test bench to commission a third ion source beam line and a newly designed extraction system

    Energy Technology Data Exchange (ETDEWEB)

    Winkelmann, T.; Cee, R.; Haberer, T.; Naas, B.; Peters, A. [Heidelberger Ionenstrahl-Therapie Centrum (HIT), D-69120 Heidelberg (Germany)

    2012-02-15

    The HIT (Heidelberg Ion Beam Therapy Center) is the first hospital-based treatment facility in Europe where patients can be irradiated with protons and carbon ions. Since the commissioning starting in 2006 two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce a variety of ion beams from protons up to oxygen. In the future a helium beam for regular patient treatment is requested, therefore a third ion source (Supernanogan source from PANTECHNIK S.A.) will be integrated. This third ECR source with a newly designed extraction system and a spectrometer line is installed at a test bench at HIT to commission and validate this section. Measurements with different extraction system setups will be presented to show the improvement of beam quality for helium, proton, and carbon beams. An outlook to the possible integration scheme of the new ion source into the production facility will be discussed.

  14. Test bench to commission a third ion source beam line and a newly designed extraction system.

    Science.gov (United States)

    Winkelmann, T; Cee, R; Haberer, T; Naas, B; Peters, A

    2012-02-01

    The HIT (Heidelberg Ion Beam Therapy Center) is the first hospital-based treatment facility in Europe where patients can be irradiated with protons and carbon ions. Since the commissioning starting in 2006 two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce a variety of ion beams from protons up to oxygen. In the future a helium beam for regular patient treatment is requested, therefore a third ion source (Supernanogan source from PANTECHNIK S.A.) will be integrated. This third ECR source with a newly designed extraction system and a spectrometer line is installed at a test bench at HIT to commission and validate this section. Measurements with different extraction system setups will be presented to show the improvement of beam quality for helium, proton, and carbon beams. An outlook to the possible integration scheme of the new ion source into the production facility will be discussed.

  15. Helium heater design for the helium direct cycle component test facility. [for gas-cooled nuclear reactor power plant

    Science.gov (United States)

    Larson, V. R.; Gunn, S. V.; Lee, J. C.

    1975-01-01

    The paper describes a helium heater to be used to conduct non-nuclear demonstration tests of the complete power conversion loop for a direct-cycle gas-cooled nuclear reactor power plant. Requirements for the heater include: heating the helium to a 1500 F temperature, operating at a 1000 psia helium pressure, providing a thermal response capability and helium volume similar to that of the nuclear reactor, and a total heater system helium pressure drop of not more than 15 psi. The unique compact heater system design proposed consists of 18 heater modules; air preheaters, compressors, and compressor drive systems; an integral control system; piping; and auxiliary equipment. The heater modules incorporate the dual-concentric-tube 'Variflux' heat exchanger design which provides a controlled heat flux along the entire length of the tube element. The heater design as proposed will meet all system requirements. The heater uses pressurized combustion (50 psia) to provide intensive heat transfer, and to minimize furnace volume and heat storage mass.

  16. A cryogenic axial-centrifugal compressor for superfluid helium refrigeration

    CERN Document Server

    Decker, L; Schustr, P; Vins, M; Brunovsky, I; Lebrun, P; Tavian, L

    1997-01-01

    CERN's new project, the Large Hadron Collider (LHC), will use superfluid helium as coolant for its high-field superconducting magnets and therefore require large capacity refrigeration at 1.8 K. This may only be achieved by subatmospheric compression of gaseous helium at cryogenic temperature. To stimulate development of this technology, CERN has procured from industry prototype Cold Compressor Units (CCU). This unit is based on a cryogenic axial-centrifugal compressor, running on ceramic ball bearings and driven by a variable-frequency electrical motor operating under low-pressure helium at ambient temperature. The machine has been commissioned and is now in operation. After describing basic constructional features of the compressor, we report on measured performance.

  17. Helium and neon isotopes in deep Pacific Ocean sediments

    Science.gov (United States)

    Nier, A. O.; Schlutter, D. J.; Brownlee, D. E.

    1990-01-01

    Helium and neon concentration measurements, along with isotope ratio determinations, have been made for particles collected in the deep Pacific with a magnetic sled, and they are believed to be of extraterrestrial origin. Analyses were made for samples consisting of composites of many extremely fine particles and for several individual particles large enough to contain sufficient gas for analysis but small enough to escape melting in their passage through the atmosphere. Step-heating was employed to extract the gas. Cosmic-ray spallation products or solar-wind helium and neon, if present, were not abundant enough to account for the isotopic compositions measured. In the case of the samples of magnetic fines, the low temperature extractions provided elemental and isotopic ratios in the general range found for the primordial gas in carbonaceous chondrites and gas-rich meteorites. The isotopic ratios found in the high temperature extractions suggest the presence of solar-flare helium and neon.

  18. The Story of Helium and the Birth of Astrophysics

    CERN Document Server

    Nath, Biman B

    2013-01-01

    Biman Nath The Story of Helium and the Birth of Astrophysics Helium was the first element ever discovered by astronomers. Its presence was first indicated in the Sun and not on Earth. Further, its discovery marked the birth of the new science of astrophysics. However, it turns out that the events leading to the discovery of helium have been rather misrepresented in books, journals, and even encyclopedias. The usual story about its joint discovery during a solar eclipse in 1868 by French astronomer Pierre Janssen and late in England by Norman Lockyer, is far from the truth. Janssen never mentioned any new spectral line in his reports. The actual story turns out to be as dramatic as in fiction. This book tells the story without jargon, using the words of the scientists themselves (from their letters and reports), and rescues the real story from the backwaters of history.

  19. Commissioning of the JT-60SA helium refrigerator

    Science.gov (United States)

    Kamiya, Koji; Natsume, Kyohei; Ohtsu, Kiichi; Oishi, Makoto; Honda, Atsushi; Kashiwa, Yoshitoshi; Kizu, Kaname; Koide, Yoshihiko; Hoa, Christine; Michel, Frederic; Roussel, Pascal; Lamaison, Valerie; Bonne, Francois; Dipietro, Enrico; Cardella, Antonino; Wanner, Manfred; Legrand, Jerome; Pudys, Vincent; Langevin, Baptiste

    2017-09-01

    The JT-60SA project will use superconducting magnets to confine the plasma and achieve a plasma current with a typical flat top duration of 100 second in purely inductive mode. The helium refrigerator has an equivalent cooling power of 9 kW at 4.5 K providing 3.7 K, 4.5 K, 50 K and 80 K for the diverter cryopump, the superconducting magnets, the HTS current leads, and the thermal shields, respectively. This paper summarizes the JT-60SA helium refrigerator commissioning activities aiming at successful operation of heat load smoothing technology to manage the 12 kW heat pulses by 9 kW cooling power using a 7000 liter liquid helium.

  20. A quantitative experiment on the fountain effect in superfluid helium

    Science.gov (United States)

    Amigó, M. L.; Herrera, T.; Neñer, L.; Peralta Gavensky, L.; Turco, F.; Luzuriaga, J.

    2017-09-01

    Superfluid helium, a state of matter existing at low temperatures, shows many remarkable properties. One example is the so called fountain effect, where a heater can produce a jet of helium. This converts heat into mechanical motion; a machine with no moving parts, but working only below 2 K. Allen and Jones first demonstrated the effect in 1938, but their work was basically qualitative. We now present data of a quantitative version of the experiment. We have measured the heat supplied, the temperature and the height of the jet produced. We also develop equations, based on the two-fluid model of superfluid helium, that give a satisfactory fit to the data. The experiment has been performed by advanced undergraduate students in our home institution, and illustrates in a vivid way some of the striking properties of the superfluid state.

  1. Helium and mercury in the central Seward Peninsula

    Energy Technology Data Exchange (ETDEWEB)

    Wescott, E.; Ruscetta, C.A.; Foley, D. (eds.)

    1981-05-01

    The central Seward Peninsula, Alaska, has one Known Geothermal Resource Area (KGRA) at Pilgrim Springs, and has recent volcanic flows, fault systems, topographic and tectonic features which can be explained by a rift model. As part of a geothermal reconnaissance of the area we used helium and mercury concentrations in soil as indicators of geothermal resources. The largest helium concentrations were found in the vicinity of the Pilgrims Springs KGRA, and indicate prime drilling sites. Five profile lines were run across the suspected rift system. Significant helium anomalies were found on several of the traverses, where future exploration might be concentrated. Mercury values showed a great range of variability on the traverses, and seem unreliable as geothermal indicators except in the vicinity of the Pilgrim Springs. Permafrost at the surface resulting in variations in sampling depth may contribute to the mercury variations.

  2. Supersonic jets of hydrogen and helium for laser wakefield acceleration

    CERN Document Server

    Svensson, K.; Wojda, F.; Senje, L.; Burza, M.; Aurand, B.; Genoud, G.; Persson, A.; Wahlström, C.-G.; Lundh, O.

    2016-01-01

    The properties of laser wakefield accelerated electrons in supersonic gas flows of hydrogen and helium are investigated. At identical backing pressure, we find that electron beams emerging from helium show large variations in their spectral and spatial distributions, whereas electron beams accelerated in hydrogen plasmas show a higher degree of reproducibility. In an experimental investigation of the relation between neutral gas density and backing pressure, it is found that the resulting number density for helium is ∼30% higher than for hydrogen at the same backing pressure. The observed differences in electron beam properties between the two gases can thus be explained by differences in plasma electron density. This interpretation is verified by repeating the laser wakefield acceleration experiment using similar plasma electron densities for the two gases, which then yielded electron beams with similar properties.

  3. 3D CFD Transient Numerical Simulation of Superfluid Helium

    Science.gov (United States)

    Bruce, R.; Reynaud, J.; Pascali, S.; Baudouy, B.

    2017-12-01

    Numerical simulations of superfluid helium are necessary to design the next generation of superconducting accelerator magnets at CERN. Previous studies have presented the thermodynamic equations implemented in the Fluent CFD software to model the thermal behavior of superfluid helium. Momentum and energy equations have been modified in the solver to model a simplified two-fluid model. In this model, the thermo-mechanical effect term and the Gorter-Mellink mutual friction term are the dominant terms in the momentum equation for the superfluid component. This assumption is valid for most of superfluid applications. Transient thermal and dynamic behavior of superfluid helium has been studied in this paper. The equivalent thermal conductivity in the energy equation is represented by the Gorter-Mellink term and both the theoretical and the Sato formulation of this term have been compared to unsteady helium superfluid experiments. The main difference between these two formulations is the coefficient to the power of the temperature gradient between the hot and the cold part in the equivalent thermal conductivity. The results of these unsteady simulations have been compared with two experiments. The first one is a Van Sciver experiment on a 10 m long, and 9 mm diameter tube at saturation conditions and the other, realized in our laboratory, is a 150×50×10 mm rectangular channel filled with pressurized superfluid helium. Both studies have been performed with a heating source that starts delivering power at the beginning of the experiment and many temperature sensors measure the transient thermal behavior of the superfluid helium along the length of the channel.

  4. Application of helium isotopes to studies of ocean circulation

    Science.gov (United States)

    Schlosser, P.; Newton, R.; Winckler, G.; Lupton, J.; Jenkins, W.; Top, Z.; Roether, W.; Jean-Baptiste, P.

    2004-12-01

    Since the discovery of excess He-3 in the ocean by Clarke and Craig in the 1960's helium isotopes have been used in local, regional and global studies of circulation patterns and water mass transformation in the world ocean. From initial pilot studies through systematic exploration of these tracers during the GEOSECS (Geochemical Ocean Sections) program to the recent global survey as part of the WOCE (World Ocean Circulation Experiment) hydrographic program (WHP) we obtained more detailed information on the distribution of helium isotopes, as well as their sources and sinks in the ocean. This information can now be applied to construct global fields of helium isotopes and to extract unique information on the circulation patterns at different depth levels in the ocean, as well as on local and regional processes such as ventilation of water masses in deep water formation regions. Additionally, the data sets are now sufficiently large to be useful for validation of Ocean General Circulation Models (OGCM's). In this contribution we present examples of global helium isotope fields constructed from major programs such as GEOCECS, TTO (Transient Tracers in the Ocean), SAVE (South Atlantic Ventilation Experiment) and WOCE, as well as from individual ocean sections. We use the data to delineate circulation patterns in the major ocean basins at several depth levels, especially mid-depth waters. Additionally, we outline the use of helium isotopes in studies of ocean ventilation. Finally, we compare observed and simulated helium isotope fields to highlight OGCM capabilities and deficiencies to reproduce internal He-3 excesses in the ocean and the related ventilation processes.

  5. High temperature indentation of helium-implanted tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Gibson, James S.K.-L., E-mail: james.gibson@materials.ox.ac.uk [Oxford University, Department of Materials, Parks Road, Oxford OX1 3PH (United Kingdom); Roberts, Steve G. [Oxford University, Department of Materials, Parks Road, Oxford OX1 3PH (United Kingdom); Culham Centre for Fusion Energy, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Armstrong, David E.J. [Oxford University, Department of Materials, Parks Road, Oxford OX1 3PH (United Kingdom)

    2015-02-11

    Nanoindentation has been performed on tungsten, unimplanted and helium-implanted to ~600 appm, at temperatures up to 750 °C. The hardening effect of the damage was 0.90 GPa at 50 °C, but is negligible above 450 °C. The hardness value at a given temperature did not change on re-testing after heating to 750 °C. This suggests that the helium is trapped in small vacancy complexes that are stable to at least 750 °C, but which can be bypassed due to increased dislocation mobility (cross slip or climb) above 450 °C.

  6. Supercritical Helium Cooling of the LHC Beam Screens

    CERN Document Server

    Hatchadourian, E; Tavian, L

    1998-01-01

    The cold mass of the LHC superconducting magnets, operating in pressurised superfluid helium at 1.9 K, must be shielded from the dynamic heat loads induced by the circulating particle beams, by means of beam screens maintained at higher temperature. The beam screens are cooled between 5 and 20 K by forced flow of weakly supercritical helium, a solution which avoids two-phase flow in the long, narr ow cooling channels, but still presents a potential risk of thermohydraulic instabilities. This problem has been studied by theoretical modelling and experiments performed on a full-scale dedicated te st loop.

  7. Hydrogen-Helium shock Radiation tests for Saturn Entry Probes

    Science.gov (United States)

    Cruden, Brett A.

    2016-01-01

    This paper describes the measurement of shock layer radiation in Hydrogen/Helium mixtures representative of that encountered by probes entering the Saturn atmosphere. Normal shock waves are measured in Hydrogen-Helium mixtures (89:11% by volume) at freestream pressures between 13-66 Pa (0.1-0.5 Torr) and velocities from 20-30 km/s. Radiance is quantified from the Vacuum Ultraviolet through Near Infrared. An induction time of several centimeters is observed where electron density and radiance remain well below equilibrium. Radiance is observed in front of the shock layer, the characteristics of which match the expected diffusion length of Hydrogen.

  8. A Neutron Scattering Study of Collective Excitations in Superfluid Helium

    DEFF Research Database (Denmark)

    Graf, E. H.; Minkiewicz, V. J.; Bjerrum Møller, Hans

    1974-01-01

    Extensive inelastic-neutron-scattering experiments have been performed on superfluid helium over a wide range of energy and momentum transfers. A high-resolution study has been made of the pressure dependence of the single-excitation scattering at the first maximum of the dispersion curve over...... of the multiexcitation scattering was also studied. It is shown that the multiphonon spectrum of a simple Debye solid with the phonon dispersion and single-excitation cross section of superfluid helium qualitatively reproduces these data....

  9. K2 spots rotation in the helium star HD144941

    Science.gov (United States)

    Jeffery, C. Simon; Ramsay, Gavin

    2018-02-01

    HD144941 is an evolved early-type metal-poor low-mass star with a hydrogen-poor surface. It is frequently associated with other intermediate helium-rich subdwarfs and extreme helium stars. Previous photometric studies have failed to detect any variability. New observations with the K2 mission show complex but periodic variations with a full amplitude of 4 parts per thousand. It is proposed that these are due to an inhomogeneous surface brightness distribution (spots) superimposed on a rotation period of 13.9 ± 0.2 d. The cause of the surface inhomogeneity is not identified, although an oblique dipolar magnetic field origin is plausible.

  10. REVIEWS OF TOPICAL PROBLEMS: Optical polarization of helium-3 nuclei

    Science.gov (United States)

    Laloë, F.; Leduc, M.; Nacher, P.-J.; Novikov, L. N.; Tastevin, G.

    1985-11-01

    The present state of the problem of producing highly polarized systems of helium-3 by laser optical pumping over a broad temperature range is reviewed. The physical principles underlying the polarization of 3He nuclei during optical pumping and the exchange of metastability are described. Particular features of laser pumping at low temperatures are discussed. The possible use of polarized helium atoms in research on exchange and relaxation processes, in quantum magnetometry, and in nuclear physics to produce polarized targets and particle beams is discussed. The results of theoretical and experimental research on the quantum properties of highly polarized systems at low temperatures, near the temperature of quantum degeneracy, are reviewed.

  11. Heat transport of nitrogen in helium atmospheric pressure microplasma

    CERN Document Server

    Xu, Shaofeng

    2013-01-01

    Stable DC atmospheric pressure normal glow discharges in ambient air were produced between the water surface and the metallic capillary coupled with influx of helium gas. Multiple independent repeated trials indicated that vibrational temperature of nitrogen rises from 3200 to 4622 K, and rotational temperature of nitrogen decreases from 1270 to 570 K as gas flux increasing from 20 to 80 sccm and discharge current decreasing from 11 to 3 mA. Furthermore, it was found that the vibrational degree of the nitrogen molecule has priority to gain energy than the rotational degree of nitrogen molecule in nonequilibrium helium microplasma.

  12. Methods of Helium Injection and Removal for Heat Transfer Augmentation

    Science.gov (United States)

    Haight, Harlan; Kegley, Jeff; Bourdreaux, Meghan

    2008-01-01

    While augmentation of heat transfer from a test article by helium gas at low pressures is well known, the method is rarely employed during space simulation testing because the test objectives usually involve simulation of an orbital thermal environment. Test objectives of cryogenic optical testing at Marshall Space Flight Center's X-ray Cryogenic Facility (XRCF) have typically not been constrained by orbital environment parameters. As a result, several methods of helium injection have been utilized at the XRCF since 1999 to decrease thermal transition times. A brief synopsis of these injection (and removal) methods including will be presented.

  13. Detectability of Light Dark Matter with Superfluid Helium.

    Science.gov (United States)

    Schutz, Katelin; Zurek, Kathryn M

    2016-09-16

    We show that a two-excitation process in superfluid helium, combined with sensitivity to meV energy depositions, can probe dark matter down to the ∼keV warm dark matter mass limit. This mass reach is 3 orders of magnitude below what can be probed with ordinary nuclear recoils in helium at the same energy resolution. For dark matter lighter than ∼100  keV, the kinematics of the process requires the two athermal excitations to have nearly equal and opposite momentum, potentially providing a built-in coincidence mechanism for controlling backgrounds.

  14. Sodium dopants in helium clusters: Structure, equilibrium and submersion kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, F. [Laboratoire Interdisciplinaire de Physique, Rue de La Piscine, Campus Saint Martin d’Hères, 38000 Grenoble (France)

    2015-12-31

    Alkali impurities bind to helium nanodroplets very differently depending on their size and charge state, large neutral or charged dopants being wetted by the droplet whereas small neutral impurities prefer to reside aside. Using various computational modeling tools such as quantum Monte Carlo and path-integral molecular dynamics simulations, we have revisited some aspects of the physical chemistry of helium droplets interacting with sodium impurities, including the onset of snowball formation in presence of many-body polarization forces, the transition from non-wetted to wetted behavior in larger sodium clusters, and the kinetics of submersion of small dopants after sudden ionization.

  15. Gas flow rate dependence of the discharge characteristics of a helium atmospheric pressure plasma jet interacting with a substrate

    Science.gov (United States)

    Yan, Wen; Economou, Demetre J.

    2017-10-01

    A 2D (axisymmetric) computational study of the discharge characteristics of an atmospheric pressure plasma jet as a function of gas flow rate was performed. The helium jet emerged from a dielectric tube, with an average gas flow velocity in the range 2.5-20 m s-1 (1 atm, 300 K) in a nitrogen ambient, and impinged on a substrate a short distance dowstream. The effect of the substrate conductivity (conductror versus insulator) was also studied. Whenever possible, simulation predictions were compared with published experimental observations. Discharge ignition and propagation in the dielectric tube were hardly affected by the He gas flow velocity. Most properties of the plasma jet, however, depended sensitively on the He gas flow velocity, which determined the concentration distributions of helium and nitrogen in the mixing layer forming in the gap between the tube exit and the substrate. At low gas flow velocity, the plasma jet evolved from a hollow (donut-shaped) feature to one where the maximum of electron density was on axis. When the gas flow velocity was high, the plasma jet maintained its hollow structure until it struck the substrate. For a conductive substrate, the radial ion fluxes to the surface were relatively uniform over a radius of ~0.4-0.8 mm, and the dominant ion flux was that of He+. For a dielectric substrate, the radial ion fluxes to the surface peaked on the symmetry axis at low He gas flow velocity, but a hollow ion flux distribution was observed at high gas flow velocity. At the same time, the main ion flux switched from N2+ to He2+ as the He gas flow velocity increased from a low to a high value. The diameter of the plasma ‘footprint’ on the substrate first increased with increasing He gas flow velocity, and eventually saturated with further increases in velocity.

  16. Observation of doubly-charged ions of francium isotopes extracted from a gas cell

    Science.gov (United States)

    Schury, P.; Wada, M.; Ito, Y.; Kaji, D.; Haba, H.; Hirayama, Y.; Kimura, S.; Koura, H.; MacCormick, M.; Miyatake, H.; Moon, J. Y.; Morimoto, K.; Morita, K.; Murray, I.; Ozawa, A.; Rosenbusch, M.; Reponen, M.; Takamine, A.; Tanaka, T.; Watanabe, Y. X.; Wollnik, H.

    2017-09-01

    Various isotopes of Ac, Ra, Fr, and Rn were produced by fusion-evaporation reactions using a 48Ca beam. The energetic ions were stopped in and extracted from a helium gas cell. The extracted ions were identified using a multi-reflection time-of-fight mass spectrograph. In all cases, it was observed that the predominant charge state for the extracted ions, including the alkali Fr, was 2+.

  17. Ion Acceleration by Double Layers with Multi-Component Ion Species

    Science.gov (United States)

    Good, Timothy; Aguirre, Evan; Scime, Earl; West Virginia University Team

    2017-10-01

    Current-free double layers (CFDL) models have been proposed to explain observations of magnetic field-aligned ion acceleration in plasmas expanding into divergent magnetic field regions. More recently, experimental studies of the Bohm sheath criterion in multiple ion species plasma reveal an equilibration of Bohm speeds at the sheath-presheath boundary for a grounded plate in a multipole-confined filament discharge. We aim to test this ion velocity effect for CFDL acceleration. We report high resolution ion velocity distribution function (IVDF) measurements using laser induced fluorescence downstream of a CFDL in a helicon plasma. Combinations of argon-helium, argon-krypton, and argon-xenon gases are ionized and measurements of argon or xenon IVDFs are investigated to determine whether ion acceleration is enhanced (or diminished) by the presence of lighter (or heavier) ions in the mix. We find that the predominant effect is a reduction of ion acceleration consistent with increased drag arising from increased gas pressure under all conditions, including constant total gas pressure, equal plasma densities of different ions, and very different plasma densities of different ions. These results suggest that the physics responsible for acceleration of multiple ion species in simple sheaths is not responsible for the ion acceleration observed in these expanding plasmas. Department of Physics, Gettysburg College.

  18. Operational Experience with The GTS-LHC Ion Source and Future Developments of The CERN Ion Injector

    CERN Document Server

    Kuchler, D; Lombardi, A; O'Neil, M; Scrivens, R; Stafford-Haworth, J; Thomae, R

    2012-01-01

    Since 2010 the GTS-LHC source delivers lead ions for heavy ion physics at the LHC. Several modifications allowed the improvement the source reliability and the beam stability. The attempts to improve the beam intensity were less successful. The different modifications and actual performance figures will be presented in this paper. In addition to the heavy ion physics program of the LHC new ion species will be requested for different experiments in the future. The fixed target experiment NA61 requires primary argon and xenon beams. And a future biomedical facility asks for light ions in the range helium to neon. Approaches to prepare these beams and to modify the ion injector towards a light ion front end are presented.

  19. Recent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited).

    Science.gov (United States)

    Kitagawa, A; Drentje, A G; Fujita, T; Muramatsu, M; Fukushima, K; Shiraishi, N; Suzuki, T; Takahashi, K; Takasugi, W; Biri, S; Rácz, R; Kato, Y; Uchida, T; Yoshida, Y

    2016-02-01

    With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.

  20. 43 CFR 16.1 - Agreements to dispose of helium in natural gas.

    Science.gov (United States)

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Agreements to dispose of helium in natural gas. 16.1 Section 16.1 Public Lands: Interior Office of the Secretary of the Interior CONSERVATION OF HELIUM § 16.1 Agreements to dispose of helium in natural gas. (a) Pursuant to his authority and...

  1. Helium inhalation in adolescents: characteristics of users and prevalence of use.

    Science.gov (United States)

    Whitt, Ahmed; Garland, Eric L; Howard, Matthew O

    2012-01-01

    Although helium-related fatalities and concerns about potentially harmful effects of helium use have increased in recent years, virtually nothing is known about the epidemiology of helium inhalation in adolescents. This exploratory investigation examined the prevalence and correlates of helium inhalation in a large sample of at-risk youth. Study participants were 723 Missouri adolescents (M age = 15.5, SD = 1.2) in residential treatment for delinquent behavior. More than one-in-nine (N = 81, 11.5%) adolescents had inhaled helium with the intention of getting high, and one-third (N = 27, 34.2%) of helium users reported they actually did get high when they inhaled helium. Helium users were significantly more likely to be Caucasian, to live in rural/small town areas, and to have histories of mental illness, auditory hallucinations, and alcohol and marijuana use than nonusers. Helium users also reported significantly more current psychiatric distress, suicidality, traumatic life experiences, and antisocial attitudes, traits, and behaviors than nonusers. Helium inhalation was prevalent in this sample and many such users reported getting high while using helium. Helium users had psychosocial profiles similar to those of volatile solvent users, suggesting that they may be at substantial risk for a variety of adverse health outcomes.

  2. 76 FR 30362 - Federal Acquisition Regulation; Submission for OMB Review; Acquisition of Helium

    Science.gov (United States)

    2011-05-25

    ...; Submission for OMB Review; Acquisition of Helium AGENCY: Department of Defense (DOD), General Services... approved information collection requirement concerning acquisition of helium. Public comments are... Collection 9000- 0113, Acquisition of Helium, by any of the following methods: Regulations.gov : http://www...

  3. 76 FR 12357 - Federal Acquisition Regulation; Information Collection; Acquisition of Helium

    Science.gov (United States)

    2011-03-07

    ... Helium AGENCY: Department of Defense (DOD), General Services Administration (GSA), and National... requirement concerning acquisition of helium. Public comments are particularly invited on: Whether this...: A. Purpose The Helium Act (Pub. L. 86-777) (50 U.S.C. 167a, et seq.) and the Department of the...

  4. Helium implanted AlHf as studied by 181 Ta TDPAC

    Indian Academy of Sciences (India)

    Measurements on helium implanted sample indicate the binding of helium associated defects by Hf solute clusters. Isochronal annealing measurements indicate the dissociation of the helium implantation induced defects from Hf solute clusters for annealing treatments beyond 650 K. On comparison of the present results ...

  5. Path integral Monte Carlo calculations of helium and hydrogen-helium plasma thermodynamics and of the deuterium shock Hugoniot

    Energy Technology Data Exchange (ETDEWEB)

    Levashov, P R [Institute for High Energy Densities, RAS, Izhorskaya 13/19, Moscow 125412 (Russian Federation); Filinov, V S [Institute for High Energy Densities, RAS, Izhorskaya 13/19, Moscow 125412 (Russian Federation); Bonitz, M [Christian-Albrechts-Universitaet zu Kiel, Institut fuer Theoretische Physik und Astrophysik, Leibnizstr. 15, 24098 Kiel (Germany); Fortov, V E [Institute for High Energy Densities, RAS, Izhorskaya 13/19, Moscow 125412 (Russian Federation)

    2006-04-28

    In this work, we calculate the thermodynamic properties of hydrogen-helium plasmas with different mass fractions of helium by the direct path integral Monte Carlo method. To avoid unphysical approximations, we use the path integral representation of the density matrix. We pay special attention to the region of weak coupling and degeneracy and compare the results of simulation with a model based on the chemical picture. Further with the help of calculated deuterium isochors, we compute the shock Hugoniot of deuterium. We analyse our results in comparison with recent experimental and calculated data on the deuterium Hugoniot.

  6. MR implant labelling and its use in clinical MRI practice; MR-Implantatkennzeichnungen und ihre Anwendung in der klinischen MRT-Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenweg, M. [Krankenhaus Martha-Maria Halle-Doelau, Institut fuer Radiologie, Halle (Saale) (Germany); Schaefers, G. [MR:comp GmbH, Gelsenkirchen (Germany)

    2015-08-15

    Messungen von Patienten mit Implantaten. In juengerer Vergangenheit ist jedoch ein Weg geschaffen worden, diese Kontraindikation legal zu umgehen. Hierfuer sind spezielle Voraussetzungen noetig: Eindeutige Implantatidentifikation und Vorlage der originalen Herstellerkennzeichnung, Gewaehrleistung der geforderten Bedingungen bei ''bedingt MR-sicheren'' Implantaten und Restrisiko-Nutzen-Analyse mit entsprechender Aufklaerung. Dieser Prozess ist u. U. sehr aufwendig, da die Implantate haeufig schlecht dokumentiert und die Detailinformationen der Implantatkennzeichnung ebenfalls nicht selten veraltet oder nicht einfach zu interpretieren sind. Diese Arbeit informiert ueber rechtliche und normative Grundlagen der Messung von Patienten mit Implantaten. Es werden kurz moegliche physikalische Wechselwirkungen mit Implantaten angerissen, moegliche Strategien zur besseren Identifikation und Recherche von Implantaten und ihrer MR-Kennzeichnung aufgezeigt und allgemeine Ansaetze zur Risikominimierung an Beispielen diskutiert. Der zweite Teil geht auf die Inhalte von MR-Implantatkennzeichnungen ein und zeigt die aktuellen Pruefstandards auf. Es werden die fuer die Interpretation von MR-Implantatkennzeichnungen notwendigen Zusatzinformationen aus den Betriebsanleitungen der MR-Scanner erlaeutert. Abschliessend folgen die Erklaerung der aktuellen Muster-MR-Kennzeichnung von Implantaten der FDA (US Food and Drug Administration) und eine exemplarische Anwendung. (orig.)

  7. Dissolved helium and TDS in groundwater from Bhavnagar in Gujarat

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    2003-01-02

    Jan 2, 2003 ... quake related or induced by other environmental. Keywords. Groundwater; Helium; TDS; Bhavnagar; seismicity. Proc. Indian Acad. Sci. (Earth Planet. Sci.) .... (ppm AEU) surface. Sample. Well type. Location lithology. Depth. Sept. Jan. March. Sept. Jan. March. Sept. Jan. March code. TW/HP name. AL/BAS.

  8. Molecular Iodine Fluorescence Using a Green Helium-Neon Laser

    Science.gov (United States)

    Williamson, J. Charles

    2011-01-01

    Excitation of molecular iodine vapor with a green (543.4 nm) helium-neon laser produces a fluorescence spectrum that is well suited for the upper-level undergraduate physical chemistry laboratory. Application of standard evaluation techniques to the spectrum yields ground electronic-state molecular parameters in good agreement with literature…

  9. Apparatus to measure low level helium for neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Shuji; Takao, Yoshiyuki; Muramasu, Masatomo; Hida, Tomoya; Sou, Hirofumi; Nakashima, Hideki [Kyushu Univ., Fukuoka (Japan); Kanda, Yukinori

    1998-03-01

    An apparatus to measure low level helium in a solid sample for neutron dosimetry in the practical use such as area monitoring in the long-term and reactor surveillance was reported. In our previous work, the helium atoms measurement system (HAMS) was developed. A sample was evaporated in the furnace and the released gas from the sample was analyzed with the mass spectrometer of the system to determine the amount of helium contained in it. The system has been improved to advance the lower helium measurement limit in a solid sample for its application to an area monitoring system. The mass of a solid is up to 100mg. Two important points should be considered to advance the lower limit. One was to produce a high quality vacuum in the system chamber for suppressing background gases during the sample measurement. The other important point was to detect very small output from the mass spectrometer. A pulse counting system was used to get high sensitivity in the mass 4 analyzing. (author)

  10. TRANSMISSION ELECTRON MICROSCOPY STUDY OF HELIUM BEARING FUSION WELDS

    Energy Technology Data Exchange (ETDEWEB)

    Tosten, M; Michael Morgan, M

    2008-12-12

    A transmission electron microscopy (TEM) study was conducted to characterize the helium bubble distributions in tritium-charged-and-aged 304L and 21Cr-6Ni-9Mn stainless steel fusion welds containing approximately 150 appm helium-3. TEM foils were prepared from C-shaped fracture toughness test specimens containing {delta} ferrite levels ranging from 4 to 33 volume percent. The weld microstructures in the low ferrite welds consisted mostly of austenite and discontinuous, skeletal {delta} ferrite. In welds with higher levels of {delta} ferrite, the ferrite was more continuous and, in some areas of the 33 volume percent sample, was the matrix/majority phase. The helium bubble microstructures observed were similar in all samples. Bubbles were found in the austenite but not in the {delta} ferrite. In the austenite, bubbles had nucleated homogeneously in the grain interiors and heterogeneously on dislocations. Bubbles were not found on any austenite/austenite grain boundaries or at the austenite/{delta} ferrite interphase interfaces. Bubbles were not observed in the {delta} ferrite because of the combined effects of the low solubility and rapid diffusion of tritium through the {delta} ferrite which limited the amount of helium present to form visible bubbles.

  11. Helium Neon laser therapy for post mastectomy lymphedema and ...

    African Journals Online (AJOL)

    The aim of this work was to evaluate the efficacy of Helium Neon (He–Ne) laser therapy on post mastectomy lymphedema and shoulder mobility. Thirty female patients with axillary lymph node dissection (ALND), with or without radiotherapy had been participated in this study. The patients were randomly divided into two ...

  12. Turbulent Mixing on Helium-accreting White Dwarfs

    Science.gov (United States)

    Piro, Anthony L.

    2015-03-01

    An attractive scenario for producing Type Ia supernovae (SNe Ia) is a double detonation, where detonation of an accreted helium layer triggers ignition of a C/O core. Whether or not such a mechanism can explain some or most SNe Ia depends on the properties of the helium burning, which in turn is set by the composition of the surface material. Using a combination of semi-analytic and simple numerical models, I explore when turbulent mixing due to hydrodynamic instabilities during the accretion process can mix C/O core material up into the accreted helium. Mixing is strongest at high accretion rates, large white dwarf (WD) masses, and slow spin rates. The mixing would result in subsequent helium burning that better matches the observed properties of SNe Ia. In some cases, there is considerable mixing that can lead to more than 50% C/O in the accreted layer at the time of ignition. These results will hopefully motivate future theoretical studies of such strongly mixed conditions. Mixing also has implications for other types of WD surface explosions, including the so-called .Ia supernovae, the calcium-rich transients (if they arise from accreting WDs), and metal-enriched classical novae.

  13. Resonances of the helium atom in a strong magnetic field

    DEFF Research Database (Denmark)

    Lühr, Armin Christian; Al-Hujaj, Omar-Alexander; Schmelcher, Peter

    2007-01-01

    We present an investigation of the resonances of a doubly excited helium atom in a strong magnetic field covering the regime B=0–100  a.u. A full-interaction approach which is based on an anisotropic Gaussian basis set of one-particle functions being nonlinearly optimized for each field strength...

  14. Suicidal asphyxiation by using helium – two case reports

    Directory of Open Access Journals (Sweden)

    Anna Smędra

    2015-05-01

    Full Text Available Helium is one of inert gases causing physical asphyxiation, whose excess content in the breathing atmosphere reduces the partial pressure of oxygen and may be fatal after short-term exposure. When breathing a mixture of an inert gas (helium, nitrogen, argon with a small amount of oxygen, with the possibility of exhaling carbon dioxide, no warning signs characteristic of suffocation are perceived by the subject. Freedom from discomfort and pain, effectiveness, rapid effect and relatively easy availability of required accessories have resulted in the use of inert gases for suicidal purposes. The paper reports two cases of suicide committed by using a special kit consisting of the so-called “suicide bag” (or “exit bag” filled with helium supplied through a plastic tube. In both cases, examination of the sites where the corpses were found and analysis of collected material allowed to establish that before their death the subjects had searched the Internet for instructions on how to commit suicide using helium. Due to the advanced putrefaction process, the autopsies failed to determine the causes of their death unequivocally. However, the circumstances surrounding the deaths suggested rapid asphyxiation as a result of oxygen deficiency in the breathing mixture. Since in cases of the type discussed here the cause of death cannot generally be established by autopsy, knowledge of the circumstances of disclosure of the corpse, as well as examination of the cadaver and the death scene is of utmost importance.

  15. LOW-FIELD DIAMAGNETISM IN HELIUM RYDBERG STATES

    NARCIS (Netherlands)

    Vanderveldt, T.; Vassen, W.; Hogervorst, W.

    1992-01-01

    In a CW laser-atomic beam experiment metastable helium atoms are excited to Rydberg states (n = 58) in a magnetic field (= 0.1 T) The observed l-mixing spectra are reproduced using the method of diagonalization of the energy matrix as well as semiclassical theories. Also the first anticrossing

  16. QUASI-LANDAU STRUCTURE OF DIAMAGNETIC HELIUM RYDBERG ATOMS

    NARCIS (Netherlands)

    Vanderveldt, T.; Vassen, W.; Hogervorst, W.

    1993-01-01

    Diamagnetism in helium Rydberg atoms is studied near the ionisation threshold using constant scaled-energy laser spectroscopy. Quasi-Landau resonances in the Fouriertransform of the energy spectrum are explained using the classical periodic-orbit theory. Longlaser scans combined with a

  17. Dissolved helium and TDS in groundwater from Bhavnagar in ...

    Indian Academy of Sciences (India)

    The increase in basaltic aquifers has been explained by enhanced pumping of old groundwater with relatively higher concentration of dissolved helium and salt, whereas the decrease in alluvial aquifers has been explained by dilution from the post monsoon groundwater recharge. Therefore, the observed temporal ...

  18. Lattice location of helium in uranium dioxide single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Garrido, F.; Nowicki, L. E-mail: lech.nowicki@fuw.edu.pl; Sattonnay, G.; Sauvage, T.; Thome, L

    2004-06-01

    Lattice location of {sup 3}He atoms implanted into UO{sub 2} single crystals was performed by means of the channeling technique combined with nuclear reaction analysis (NRA) and Rutherford backscattering spectrometry (RBS). The {sup 3}He(d,p){sup 4}He reaction was used. The experimental angular scans show that helium atoms occupy octahedral interstitial positions.

  19. Automated liquid-helium transfer tube lifting system

    Science.gov (United States)

    Kato, Kiyonori; Suzui, Mitsukazu

    1990-07-01

    An automatic liquid-helium transfer tube lifting system has been developed, in which the transfer tube can be raised or lowered very slowly by remote control. This system relieves the operator of considerable manual labor, and protects the O-ring seals from damage at low temperature.

  20. Numerical simulation of losses along a natural circulation helium loop

    Energy Technology Data Exchange (ETDEWEB)

    Knížat, Branislav, E-mail: branislav.knizat@stuba.sk; Urban, František, E-mail: frantisek.urban@stuba.sk; Mlkvik, Marek, E-mail: marek.mlkvik@stuba.sk; Ridzoň, František, E-mail: frantisek.ridzon@stuba.sk; Olšiak, Róbert, E-mail: robert.olsiak@stuba.sk [Slovak University of Technology in Bratislava, Faculty of Mechanical Engineering, Nám. slobody 17, 812 31 Bratislava, Slovak Republik (Slovakia)

    2016-06-30

    A natural circulation helium loop appears to be a perspective passive method of a nuclear reactor cooling. When designing this device, it is important to analyze the mechanism of an internal flow. The flow of helium in the loop is set in motion due to a difference of hydrostatic pressures between cold and hot branch. Steady flow at a requested flow rate occurs when the buoyancy force is adjusted to resistances against the flow. Considering the fact that the buoyancy force is proportional to a difference of temperatures in both branches, it is important to estimate the losses correctly in the process of design. The paper deals with the calculation of losses in branches of the natural circulation helium loop by methods of CFD. The results of calculations are an important basis for the hydraulic design of both exchangers (heater and cooler). The analysis was carried out for the existing model of a helium loop of the height 10 m and nominal heat power 250 kW.

  1. Conceptual design of a helium heater for high temperature applications

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Xue Zhou, E-mail: jin@kit.edu; Chen, Yuming; Ghidersa, Bradut-Eugen

    2014-10-15

    Highlights: •A special design of heater with two vessels is introduced for the operation at 10 MPa and 800 °C. •The additional coupling between the cold leg and the hot leg of the loop due to the heater design has an impact on the loop energy budget. •Reducing the heat transfer between the two flow channels inside the heater by means of a helium gap in the inlet nozzle is proven to be effective. -- Abstract: The Karlsruhe Advanced Technologies Helium Loop (KATHELO) has been designed for testing divertor modules as well as qualifying materials for high heat flux, high temperature (up to 800 °C) and high pressure (10 MPa) applications. The test section inlet temperature level is controlled using a process electrical heater. To cope with the extreme operating conditions, a special design of this unit has been proposed. In this paper the conceptual design of the unit will be presented and the impact of the coupling between the cold and hot helium gas on the overall efficiency of the loop will be investigated. The detailed thermal-hydraulic analysis of the feed through of the hot helium into the low temperature pressure vessel using ANSYS CFX will be presented. The impact of the design choices on the overall energy budget of the loop will be analyzed using RELAP5-3D.

  2. Impulsive Laser Induced Alignment of Molecules Dissolved in Helium Nanodroplets

    DEFF Research Database (Denmark)

    Pentlehner, Dominik; H. Nielsen, Jens; Slenczka, Alkwin

    2013-01-01

    We show that a 450 fs nonresonant, moderately intense, linearly polarized laser pulse can induce field-free molecular axis alignment of methyliodide (CH3I) molecules dissolved in a helium nanodroplet. Time-resolved measurements reveal rotational dynamics much slower than that of isolated molecule...

  3. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  4. Maintenance free gas bearing helium blower for nuclear plant

    Science.gov (United States)

    Molyneaux, A., Dr; Harris, M., Prof; Sharkh, S., Prof; Hill, S.; de Graaff, T.

    2017-08-01

    This paper describes the design, testing and operation of novel helium blowers used to recirculate the helium blanketing gas in the nuclear reactor used as a neutron source at the Institut Laue Langevan, Grenoble, France. The laser sintered shrouded centrifugal wheel operates at speeds up to 45000 rpm supported on helium lubricated hydrodynamic spiral groove bearings, and is driven by a sensorless permanent magnet motor. The entire machine is designed to keep the helium gas (polluted by a small amount of D2O) out of contact with any iron or copper materials which would contribute to the corrosion of parts of the circuit. It is designed to have zero maintenance during a lifetime of 40,000 hours of continuous operation. This paper will describe the spiral groove journal and thrust bearings. Design and manufacture of the 1 kW motor and centrifugal wheel will be explained including their CFD and FEA analyses. Measurements of rotor displacement will be presented showing the behaviour under factory testing as well as details of the measured centrifugal wheel and motor performances. Two machines are incorporated into the circuit to provide redundancy and the first blower has been in continuous operation since Jan 2015. The blower was designed, manufactured, assembled and tested in the UK using predominantly UK suppliers.

  5. US Congress considers bill to relieve helium shortage

    Science.gov (United States)

    Gwynne, Peter

    2013-04-01

    A bill to alleviate the threat of a significant shortage of helium was set to be debated in the US House of Representatives as Physics World went to press with the House's Natural Resources Committee putting the finished touches to the motion.

  6. FAST TRACK COMMUNICATION: Contrasting characteristics of sub-microsecond pulsed atmospheric air and atmospheric pressure helium-oxygen glow discharges

    Science.gov (United States)

    Walsh, J. L.; Liu, D. X.; Iza, F.; Rong, M. Z.; Kong, M. G.

    2010-01-01

    Glow discharges in air are often considered to be the ultimate low-temperature atmospheric pressure plasmas for numerous chamber-free applications. This is due to the ubiquitous presence of air and the perceived abundance of reactive oxygen and nitrogen species in air plasmas. In this paper, sub-microsecond pulsed atmospheric air plasmas are shown to produce a low concentration of excited oxygen atoms but an abundance of excited nitrogen species, UV photons and ozone molecules. This contrasts sharply with the efficient production of excited oxygen atoms in comparable helium-oxygen discharges. Relevant reaction chemistry analysed with a global model suggests that collisional excitation of O2 by helium metastables is significantly more efficient than electron dissociative excitation of O2, electron excitation of O and ion-ion recombination. These results suggest different practical uses of the two oxygen-containing atmospheric discharges, with air plasmas being well suited for nitrogen and UV based chemistry and He-O2 plasmas for excited atomic oxygen based chemistry.

  7. Handbuch Stahl Auswahl, Verarbeitung, Anwendung

    CERN Document Server

    Bleck, Wolfgang

    2018-01-01

    Stahl ist der wichtigste Konstruktionswerkstoff. Im Maschinen- und Anlagenbau, Fahrzeugbau, Schiffbau, Stahlbau und in vielen anderen Industriebereichen ist er durch keinen anderen Werkstoff zu ersetzen. Für jeden Anwendungszweck gibt es passende Stahlsorten am Markt zu kaufen. Die Feinabstimmung der gewünschten Eigenschaften kann im weiteren Verarbeitungsprozess vorgenommen werden, bis der Werkstoff optimal den gewünschten Produktanforderungen entspricht. Die Anzahl der Möglichkeiten ist sehr groß und somit auch die Schwierigkeit, den genau passenden Stahl zu finden bzw. zu erzeugen. Das vorliegende Handbuch hilft Ihnen, dieses Problem zu lösen. Es zeigt u.a. - mit welchen systematischen Ansätzen und Hilfsmitteln Sie die in Frage kommende Stahlsorte eingrenzen können - die wichtigsten produktrelevanten Eigenschaften und Lieferformen - die werkstoffgerechte Weiterverarbeitung durch umformende und spanende Fertigungsprozesse und Wärmebehandlung - hunderte Anwendungsbeispiele aus Maschinen- und Anlage...

  8. Cold Helium Gas Pressurization For Spacecraft Cryogenic Propulsion Systems

    Science.gov (United States)

    Morehead, Robert L.; Atwell. Matthew J.; Hurlbert, Eric A.; Melcher, J. C.

    2017-01-01

    To reduce the dry mass of a spacecraft pressurization system, helium pressurant may be stored at low temperature and high pressure to increase mass in a given tank volume. Warming this gas through an engine heat exchanger prior to tank pressurization both increases the system efficiency and simplifies the designs of intermediate hardware such as regulators, valves, etc. since the gas is no longer cryogenic. If this type of cold helium pressurization system is used in conjunction with a cryogenic propellant, though, a loss in overall system efficiency can be expected due to heat transfer from the warm ullage gas to the cryogenic propellant which results in a specific volume loss for the pressurant, interpreted as the Collapse Factor. Future spacecraft with cryogenic propellants will likely have a cold helium system, with increasing collapse factor effects as vehicle sizes decrease. To determine the collapse factor effects and overall implementation strategies for a representative design point, a cold helium system was hotfire tested on the Integrated Cryogenic Propulsion Test Article (ICPTA) in a thermal vacuum environment at the NASA Glenn Research Center Plum Brook Station. The ICPTA vehicle is a small lander-sized spacecraft prototype built at NASA Johnson Space Center utilizing cryogenic liquid oxygen/liquid methane propellants and cryogenic helium gas as a pressurant to operate one 2,800lbf 5:1 throttling main engine, two 28lbf Reaction Control Engines (RCE), and two 7lbf RCEs (Figure 1). This vehicle was hotfire tested at a variety of environmental conditions at NASA Plum Brook, ranging from ambient temperature/simulated high altitude, deep thermal/high altitude, and deep thermal/high vacuum conditions. A detailed summary of the vehicle design and testing campaign may be found in Integrated Cryogenic Propulsion Test Article Thermal Vacuum Hotfire Testing, AIAA JPC 2017.

  9. Saturn's Helium Abundance from Cassini CIRS and RSS Data

    Science.gov (United States)

    Achterberg, Richard K.; Schinder, Paul J.; Flasar, F. Michael

    2016-10-01

    The ratio of helium to hydrogen in Saturn's atmosphere provides an important constraint on models of Saturn's formation and evolution, but has been poorly constrained by available data. Measurements combining Voyager infrared and radio data [1] gave a He/H2 mole ratio of 0.034 ± 0.024, far below the protosolar value and requiring either significant helium loss or sequestration in the interior. Prompted by discrepancies between the Voyager infrared/radio and Galileo probe measurements of helium on Jupiter, Conrath and Gautier [2] reevaluated the helium abundance on Saturn from Voyager infrared data only, obtaining a He/H2 mole ratio of 0.135 ± 0.025, inconsistent with the previous results. Because of this discrepancy, estimating Saturn's atmospheric helium abundance has been a major goal of the Cassini mission.We are estimating the He/H2 mole ratio in Saturn's atmosphere using a combination of data from the Cassini Radio Science Subsystem (RSS) and Composite InfraRed Spectrometer (CIRS). Radio occultations, in which a carrier signal is observed as Cassini passed behind Saturn as seen from antennas on Earth, give a vertical profile of atmospheric refractivity, which can be converted to temperature as a function of pressure assuming a mean molecular weight. The assumed molecular weight is adjusted until synthetic thermal infrared spectra match spectra observed by CIRS at the same latitude and time. Preliminary results from a set of eleven near-equatorial occultations taken in 2005 give He/H2 mole ratios varying between ~0.060 and 0.085.[1] Conrath, B. J., et al., 1984, Ap. J., 282:807-815[2] Conrath, B. J. and D. Gautier, 2000, Icarus, 144:124-134

  10. Thermophysicochemical Reaction of ZrCo-Hydrogen-Helium System

    Science.gov (United States)

    Jung, Kwangjin; Kang, Hee-Seok; Yun, Sei-Hun; Chung, Hongsuk

    2017-11-01

    Nuclear fusion energy, which is clean and infinite, has been studied for more than half a century. Efforts are in progress worldwide for the demonstration and validation of nuclear fusion energy. Korea has been developing hydrogen isotope storage and delivery system (SDS) technologies including a basic scientific study on a hydrogen storage medium. An SDS bed, which is a key component of the SDS, is used for storing hydrogen isotopes in a metal hydride form and supplying them to a tokamak. Thermophysicochemical properties of the ZrCo-H2-He system are investigated for the practical utilization of a hydriding alloy system. The hydriding reaction, in which ZrCoHx is composed as ZrCo absorbing hydrogen, is exothermic. The dehydriding reaction, in which ZrCoHx decomposes into ZrCo and hydrogen, is endothermic. The heat generated through the hydriding reaction interrupts the hydriding progress. The heat loss by a dehydriding reaction impedes the dehydriding progress. The tritium decay product, helium-3, covers the ZrCo and keeps the hydrogen from contact with ZrCo in the SDS bed. In this study, we designed and fabricated a ZrCo bed and its performance test rig. The helium blanketing effect on a ZrCo hydrogen reaction with 0 % to 20 % helium content in a gaseous phase and a helium blanket removal method were studied experimentally. In addition, the volumetric flow rates and temperature at the beginning of a ZrCo hydrogen reaction in a hydrogen or helium atmosphere, and the cooling of the SDS bed by radiation only and by both radiation and natural convection related to the reuse cycle, were obtained.

  11. Novel electrostatic column for ion projection lithography

    Energy Technology Data Exchange (ETDEWEB)

    Chalupka, A.; Stengl, G.; Buschbeck, H.; Lammer, G.; Vonach, H.; Fischer, R.; Hammel, E.; Loeschner, H.; Nowak, R.; Wolf, P. (IMS - Ion Microfabrication Systems GmbH, A-1020 Vienna (Austria)); Finkelstein, W.; Hill, R.W. (Advanced Lithography Group, Columbia, Maryland 21045 (United States)); Berry, I.L. (Department of Defense, Microelectronics Research Laboratory, Columbia, Maryland 21045 (United States)); Harriott, L.R. (AT T Bell Laboratories, Murray Hill, New Jersey 07974 (United States)); Melngailis, J. (University of Maryland, College Park, Maryland 20742 (United States)); Randall, J.N. (Texas Instruments, Dallas, Texas 75243 (United States)); Wolfe, J.C. (University of Houston, Houston, Texas 77204 (United States)); Stroh, H.; Wollnik, H. (University of Giessen, D-35392 Giessen (Germany)); Mondelli, A.A.; Petillo, J.J. (Science Applications International Corporation, McLean, Virginia 22102 (United States)); Leung, K. (Lawrence Berkeley Laboratory, University of Californi

    1994-11-01

    Ion projection lithography (IPL) is being considered for high volume sub-0.25-[mu]m lithography. A novel ion-optical column has been designed for exposing 20[times]20 mm[sup 2] fields at 3[times] reduction from stencil mask to wafer substrates. A diverging lens is realized by using the stencil mask as the first electrode of the ion-optical column. The second and third electrode form an accelerating field lens. The aberrations of the first two lenses (diverging lens and field lens) are compensated by an asymmetric Einzel lens projecting an ion image of the stencil mask openings onto the wafer substrate with better than 2 mrad telecentricity. Less than 30 nm intrafield distortion was calculated within 20[times]20 mm[sup 2] exposure fields. The calculation uncertainty is estimated to be about 10 nm. The calculation holds for helium ions with [approx]10 keV ion energy at the stencil mask and 150 keV ion energy at the wafer plane. A virtual ion source size of 10 [mu]m has been assumed. The calculated chromatic aberrations are less than 60 nm, assuming 6 eV energy spread of the ions extracted from a duoplasmatron source. Recently a multicusp ion source has been developed for which preliminary results indicate an energy spread of less than 2 eV. Thus, with a multicusp source chromatic aberrations of less than 20 nm are to be expected. The ion energy at the crossover between the field lens and the asymmetric Einzel lens is 200 keV. Therefore, stochastic space charge induced degradations in resolution can be kept sufficiently low. The divergence of the ion image projected to the wafer plane is less than 2 mrad. Thus, the usable'' depth of focus for the novel ion optics is in the order of 10 [mu]m.

  12. Probing helium interfaces with light scattering: from fluid mechanics to statistical physics.

    Science.gov (United States)

    Wolf, P E; Bonnet, F; Guyon, L; Lambert, T; Perraud, S; Puech, L; Rousset, B; Thibault, P

    2009-02-01

    We have investigated the formation of helium droplets in two physical situations. In the first one, droplets are atomised from superfluid or normal liquid by a fast helium vapour flow. In the second, droplets of normal liquid are formed inside porous glasses during the process of helium condensation. The context, aims, and results of these experiments are reviewed, with focus on the specificity of light scattering by helium. In particular, we discuss how, for different reasons, the closeness to unity of the index of refraction of helium allows in both cases to minimise the problem of multiple scattering and obtain results which it would not be possible to get using other fluids.

  13. Behaviour of high purity UO{sub 2}/H{sub 2}O interfaces under helium beam irradiation in deaerated conditions; Comportement des interfaces UO{sub 2}/H{sub 2}O de haute purete sous faisceau d'ions He{sup 2+} en milieu desaere

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, E

    2005-11-15

    A question put within the framework of the nuclear fuel storage worn in geological site is what become to them in the presence of water. The aim of a fundamental program, of PRECCI project (ECA), is to highlight the behaviour of interfaces which can be used as models for the interfaces nuclear spent fuel/water if the fuel is uranium UO{sub 2} dioxide. This doctorate is interested in the effect of the alpha activity which is the only one that exist in the spent fuel after long periods. The aim is to identify the mechanisms of alteration and of leaching of surfaces under alpha irradiation. A method is developed to irradiate UO{sub 2}/H{sub 2}O interfaces in deaerated conditions with the beam of He{sup 2+} produced by a cyclotron. The He{sup 2+} ions cross an UO{sub 2} disc and emerge in water with an energy of 5 MeV. Leachings under irradiation are carried with a large range of particles flux. The post-irradiation characterization of the surface of the discs realised by micro-Raman spectroscopy allowed to identify the alteration layer. It is made up of studtite UO{sub 2}(O{sub 2}),4H{sub 2}O, and of schoepite UO{sub 3},xH{sub 2}O. The analysis of the solutions shows that the uranium release strongly increases. The electrochemical properties of the interfaces under irradiation strongly differ from those before irradiation. This work allows to propose that the radiolytic species seen by the interface are it during the heterogeneous phase of evolution of the traces and are species of short lives. Modeling show that the radiolytic radicals species can migrate toward the interface and react with the UO{sub 2} surface. (author)

  14. Modelling third harmonic ion cyclotron acceleration of deuterium beams for JET fusion product studies experiments

    DEFF Research Database (Denmark)

    Schneider, M.; Johnson, T.; Dumont, R.

    2016-01-01

    Recent JET experiments have been dedicated to the studies of fusion reactions between deuterium (D) and Helium-3 (3He) ions using neutral beam injection (NBI) in synergy with third harmonic ion cyclotron radio-frequency heating (ICRH) of the beam. This scenario generates a fast ion deuterium tail...... ion diagnostics, showing an overall good agreement. Finally, a sawtooth activity for these experiments has been observed and interpreted using SPOT/RFOF simulations in the framework of Porcelli’s theoretical model, where NBI+ICRH accelerated ions are found to have a strong stabilizing effect, leading...

  15. Measurement of charge of heavy ions in emulsion using a CCD camera

    CERN Document Server

    Kudzia, D; Dabrowska, A; Deines-Jones, P; Holynski, R; Olszewski, A; Nilsen, B S; Sen-Gupta, K; Szarska, M; Trzupek, A; Waddington, C J; Wefel, J P; Wilczynska, B; Wilczynski, H; Wolter, W; Wosiek, B; Wozniak, K

    1999-01-01

    A system has been developed for semi-automated determination of the charges of heavy ions recorded in nuclear emulsions. The profiles of various heavy ion tracks in emulsion, both accelerator beam ions and fragments of heavy projectiles, were obtained with a CCD camera mounted on a microscope. The dependence of track profiles on illumination, emulsion grain size and density, background in emulsion, and track geometry was analyzed. Charges of the fragments of heavy projectiles were estimated independently by the delta ray counting method. A calibration of both width and height of track profiles against ion charges was made with ions of known charges ranging from helium to gold nuclei. (author)

  16. Measurement of charge of heavy ions in emulsion using a CCD camera

    Energy Technology Data Exchange (ETDEWEB)

    Kudzia, D.; Cherry, M.L.; Dabrowska, A.; Deines-Jones, P.; Holynski, R.; Olszewski, A.; Nilsen, B.S.; Sengupta, K.; Szarska, M.; Trzupek, A.; Waddington, C.J.; Wefel, J.P.; Wilczynska, B.; Wilczynski, H. E-mail: henryk.wilczynski@ifj.edu.pl; Wolter, W.; Wosiek, B.; Wozniak, K

    1999-07-11

    A system has been developed for semi-automated determination of the charges of heavy ions recorded in nuclear emulsions. The profiles of various heavy ion tracks in emulsion, both accelerator beam ions and fragments of heavy projectiles, were obtained with a CCD camera mounted on a microscope. The dependence of track profiles on illumination, emulsion grain size and density, background in emulsion, and track geometry was analyzed. Charges of the fragments of heavy projectiles were estimated independently by the delta ray counting method. A calibration of both width and height of track profiles against ion charges was made with ions of known charges ranging from helium to gold nuclei. (author)

  17. Local charge exchange of He{sup +} ions at Aluminum surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Riccardi, P., E-mail: pierfrancesco.riccardi@fis.unical.it [Dipartimento di Fisica, Università della Calabria and INFN – Gruppo collegato di Cosenza, Via P. Bucci cubo 33C, Arcavacata di Rende, Cosenza (Italy); Sindona, A. [Dipartimento di Fisica, Università della Calabria and INFN – Gruppo collegato di Cosenza, Via P. Bucci cubo 33C, Arcavacata di Rende, Cosenza (Italy); Dukes, C.A. [Laboratory for Astrophysics and Surface Physics, Materials Science and Engineering University of Virginia, Charlottesville, VA 22904 (United States)

    2017-04-04

    We report on experiments designed to observe the correlation between the autoionization of doubly excited helium atoms and the Auger decay of 2p vacancies in Al. The autoionizing states are formed when incident He{sup +*} and He{sup ++} are neutralized by resonant electron capture at the surface. 2p excitation in Al occurs in dielectronic charge transfer during the close encounter of an excited helium ion and an Al atom. These results clarify the mechanism for Al-2p excitation in the case of singly charged ground state He{sup +}(1s) ion impact, where the dielectronic transition occurs after promotion of the 1s electron of incoming ions. - Highlights: • We observe the correlation between autoionization of doubly excited helium atoms and the Auger decay of 2p vacancies in Al. • 2p excitation in Al occurs in dielectronic charge transfer during the close encounter of an excited helium ion and an Al atom. • These results clarify the mechanism for Al-2p excitation in the case of singly charged ground state He{sup +}(1s) ion impact.

  18. CERN Technical Training 2002: Learning for the LHC! HEREF-2002 : HELIUM REFRIGERATION TECHNIQUES

    CERN Multimedia

    Davide Vitè

    2002-01-01

    Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2002 is a new course, in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2002 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2002 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. Duration: 7 half days (5 mornings and 2 afternoons), 21-25 October, 2002. Estimated cost: 300.- CHF Language: Bilingual English-French. The course support will be in English, the ...

  19. CERN Technical Training 2002: Learning for the LHC ! HeREF-2002 : Helium Refrigeration Techniques

    CERN Multimedia

    Davide Vitè

    2002-01-01

    Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2002 is a new course, in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2002 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2002 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. Duration: 7 half days (5 mornings and 2 afternoons), 21-25 October 2002. Estimated cost: 300.- CHF Language: Bilingual English-French. The course support will be in English, the...

  20. Helium temperature measurements in a hot filament magnetic mirror plasma using high resolution Doppler spectroscopy

    Science.gov (United States)

    Knott, S.; McCarthy, P. J.; Ruth, A. A.

    2016-09-01

    Langmuir probe and spectroscopic diagnostics are used to routinely measure electron temperature and density over a wide operating range in a reconfigured Double Plasma device at University College Cork, Ireland. The helium plasma, generated through thermionic emission from a negatively biased tungsten filament, is confined by an axisymmetric magnetic mirror configuration using two stacks of NdFeB permanent magnets, each of length 20 cm and diameter 3 cm placed just outside the 15 mm water cooling jacket enclosing a cylindrical vacuum vessel of internal diameter 25 cm. Plasma light is analysed using a Fourier Transform-type Bruker spectrometer with a highest achievable resolution of 0.08 cm-1 . In the present work, the conventional assumption of room temperature ions in the analysis of Langmuir probe data from low temperature plasmas is examined critically using Doppler spectroscopy of the 468.6 nm He II line. Results for ion temperatures obtained from spectroscopic data for a variety of engineering parameters (discharge voltage, gas pressure and plasma current) will be presented.